Sample records for quality results obtained

  1. Positional quality assessment of orthophotos obtained from sensors onboard multi-rotor UAV platforms.

    PubMed

    Mesas-Carrascosa, Francisco Javier; Rumbao, Inmaculada Clavero; Berrocal, Juan Alberto Barrera; Porras, Alfonso García-Ferrer

    2014-11-26

    In this study we explored the positional quality of orthophotos obtained by an unmanned aerial vehicle (UAV). A multi-rotor UAV was used to obtain images using a vertically mounted digital camera. The flight was processed taking into account the photogrammetry workflow: perform the aerial triangulation, generate a digital surface model, orthorectify individual images and finally obtain a mosaic image or final orthophoto. The UAV orthophotos were assessed with various spatial quality tests used by national mapping agencies (NMAs). Results showed that the orthophotos satisfactorily passed the spatial quality tests and are therefore a useful tool for NMAs in their production flowchart.

  2. Positional Quality Assessment of Orthophotos Obtained from Sensors Onboard Multi-Rotor UAV Platforms

    PubMed Central

    Mesas-Carrascosa, Francisco Javier; Rumbao, Inmaculada Clavero; Berrocal, Juan Alberto Barrera; Porras, Alfonso García-Ferrer

    2014-01-01

    In this study we explored the positional quality of orthophotos obtained by an unmanned aerial vehicle (UAV). A multi-rotor UAV was used to obtain images using a vertically mounted digital camera. The flight was processed taking into account the photogrammetry workflow: perform the aerial triangulation, generate a digital surface model, orthorectify individual images and finally obtain a mosaic image or final orthophoto. The UAV orthophotos were assessed with various spatial quality tests used by national mapping agencies (NMAs). Results showed that the orthophotos satisfactorily passed the spatial quality tests and are therefore a useful tool for NMAs in their production flowchart. PMID:25587877

  3. Microbiological quality of five potato products obtained at retail markets.

    PubMed Central

    Duran, A P; Swartzentruber, A; Lanier, J M; Wentz, B A; Schwab, A H; Barnard, R J; Read, R B

    1982-01-01

    The microbiological quality of frozen hash brown potatoes, dried hash brown potatoes with onions, frozen french fried potatoes, dried instant mashed potatoes, and potato salad was determined by a national sampling at the retail level. A wide range of results was obtained, with most sampling units of each products having excellent microbiological quality. Geometric mean aerobic plate counts were as follows: dried hash brown potatoes, 270/g; frozen hash brown potatoes with onions, 580/g; frozen french fried potatoes 78/g; dried instant mashed potatoes, 1.1 x 10(3)/g; and potato salad, 3.6 x 10(3)/g. Mean values of coliforms, Escherichia coli, and Staphylococcus aureus were less than 10/g. PMID:6758695

  4. Measurement results obtained from air quality monitoring system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Turzanski, P.K.; Beres, R.

    1995-12-31

    An automatic system of air pollution monitoring operates in Cracow since 1991. The organization, assembling and start-up of the network is a result of joint efforts of the US Environmental Protection Agency and the Cracow environmental protection service. At present the automatic monitoring network is operated by the Provincial Inspection of Environmental Protection. There are in total seven stationary stations situated in Cracow to measure air pollution. These stations are supported continuously by one semi-mobile (transportable) station. It allows to modify periodically the area under investigation and therefore the 3-dimensional picture of creation and distribution of air pollutants within Cracowmore » area could be more intelligible.« less

  5. Quality Control for Interviews to Obtain Dietary Recalls from Children for Research Studies

    PubMed Central

    SHAFFER, NICOLE M.; THOMPSON, WILLIAM O.; BAGLIO, MICHELLE L.; GUINN, CAROLINE H.; FRYE, FRANCESCA H. A.

    2005-01-01

    Quality control is an important aspect of a study because the quality of data collected provides a foundation for the conclusions drawn from the study. For studies that include interviews, establishing quality control for interviews is critical in ascertaining whether interviews are conducted according to protocol. Despite the importance of quality control for interviews, few studies adequately document the quality control procedures used during data collection. This article reviews quality control for interviews and describes methods and results of quality control for interviews from two of our studies regarding the accuracy of children's dietary recalls; the focus is on quality control regarding interviewer performance during the interview, and examples are provided from studies with children. For our two studies, every interview was audio recorded and transcribed. The audio recording and typed transcript from one interview conducted by each research dietitian either weekly or daily were randomly selected and reviewed by another research dietitian, who completed a standardized quality control for interviews checklist. Major strengths of the methods of quality control for interviews in our two studies include: (a) interviews obtained for data collection were randomly selected for quality control for interviews, and (b) quality control for interviews was assessed on a regular basis throughout data collection. The methods of quality control for interviews described may help researchers design appropriate methods of quality control for interviews for future studies. PMID:15389417

  6. [Analysis of the results of the SEIMC External Quality Control Program. Year 2013].

    PubMed

    de Gopegui Bordes, Enrique Ruiz; Orta Mira, Nieves; Del Remedio Guna Serrano, M; Medina González, Rafael; Rosario Ovies, María; Poveda, Marta; Gimeno Cardona, Concepción

    2015-07-01

    The External Quality Control Program of the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC) include controls for bacteriology, serology, mycology, parasitology, mycobacteria, virology, molecular microbiology and HIV-1, HCV and HBV viral loads. This manuscript presents the analysis of results obtained of the participants from the 2013 SEIMC External Quality Control Programme, except viral loads controls, that they are summarized in a manuscript abroad. As a whole, the results obtained in 2013 confirm the excellent skill and good technical standards found in previous editions. However, erroneous results can be obtained in any laboratory and in clinically relevant determinations. Once again, the results of this program highlighted the need to implement both internal and external controls in order to assure the maximal quality of the microbiological tests. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  7. Results of Investigative Tests of Gas Turbine Engine Compressor Blades Obtained by Electrochemical Machining

    NASA Astrophysics Data System (ADS)

    Kozhina, T. D.; Kurochkin, A. V.

    2016-04-01

    The paper highlights results of the investigative tests of GTE compressor Ti-alloy blades obtained by the method of electrochemical machining with oscillating tool-electrodes, carried out in order to define the optimal parameters of the ECM process providing attainment of specified blade quality parameters given in the design documentation, while providing maximal performance. The new technological methods suggested based on the results of the tests; in particular application of vibrating tool-electrodes and employment of locating elements made of high-strength materials, significantly extend the capabilities of this method.

  8. Fuel quality-processing study. Volume 1: Overview and results

    NASA Technical Reports Server (NTRS)

    Jones, G. E., Jr.

    1982-01-01

    The methods whereby the intermediate results were obtained are outlined, and the evaluation of the feasible paths from liquid fossil fuel sources to generated electricity is presented. The segments from which these paths were built are the results from the fuel upgrading schemes, on-site treatments, and exhaust gas treatments detailed in the subsequent volumes. The salient cost and quality parameters are included.

  9. Calculating the quality of public high-throughput sequencing data to obtain a suitable subset for reanalysis from the Sequence Read Archive.

    PubMed

    Ohta, Tazro; Nakazato, Takeru; Bono, Hidemasa

    2017-06-01

    It is important for public data repositories to promote the reuse of archived data. In the growing field of omics science, however, the increasing number of submissions of high-throughput sequencing (HTSeq) data to public repositories prevents users from choosing a suitable data set from among the large number of search results. Repository users need to be able to set a threshold to reduce the number of results to obtain a suitable subset of high-quality data for reanalysis. We calculated the quality of sequencing data archived in a public data repository, the Sequence Read Archive (SRA), by using the quality control software FastQC. We obtained quality values for 1 171 313 experiments, which can be used to evaluate the suitability of data for reuse. We also visualized the data distribution in SRA by integrating the quality information and metadata of experiments and samples. We provide quality information of all of the archived sequencing data, which enable users to obtain sufficient quality sequencing data for reanalyses. The calculated quality data are available to the public in various formats. Our data also provide an example of enhancing the reuse of public data by adding metadata to published research data by a third party. © The Authors 2017. Published by Oxford University Press.

  10. Calculating the quality of public high-throughput sequencing data to obtain a suitable subset for reanalysis from the Sequence Read Archive

    PubMed Central

    Nakazato, Takeru; Bono, Hidemasa

    2017-01-01

    Abstract It is important for public data repositories to promote the reuse of archived data. In the growing field of omics science, however, the increasing number of submissions of high-throughput sequencing (HTSeq) data to public repositories prevents users from choosing a suitable data set from among the large number of search results. Repository users need to be able to set a threshold to reduce the number of results to obtain a suitable subset of high-quality data for reanalysis. We calculated the quality of sequencing data archived in a public data repository, the Sequence Read Archive (SRA), by using the quality control software FastQC. We obtained quality values for 1 171 313 experiments, which can be used to evaluate the suitability of data for reuse. We also visualized the data distribution in SRA by integrating the quality information and metadata of experiments and samples. We provide quality information of all of the archived sequencing data, which enable users to obtain sufficient quality sequencing data for reanalyses. The calculated quality data are available to the public in various formats. Our data also provide an example of enhancing the reuse of public data by adding metadata to published research data by a third party. PMID:28449062

  11. Changes during storage of quality parameters and in vitro antioxidant activity of extra virgin monovarietal oils obtained with two extraction technologies.

    PubMed

    Fadda, C; Del Caro, A; Sanguinetti, A M; Urgeghe, P P; Vacca, V; Arca, P P; Piga, A

    2012-10-01

    Extraction technology has a great effect on quality of olive oils. This paper studied 18 months of storage of two Sardinian extra virgin monovarietal oils obtained with a traditional and with a low oxidative stress technology. Oil samples were subjected to the following chemical analyses: acidity, peroxide value, ultraviolet light absorption K₂₃₂ and K₂₇₀, carotenoids, chlorophylls, tocopherols and total polyphenols. The antioxidant capacity of oils, polyphenol extract and oil extract (remaining after polyphenol extraction) was also determined as radical scavenging activity. The results show that both extraction technologies resulted in minor changes in legal and quality indices during storage, due surely to the high quality of the oils as well as to the very good storage conditions used. Oils obtained with the low oxidative stress technology showed lower peroxide value and acidity and resulted in up to 103% higher total polyphenol content as well as increased radical-scavenging activity, with respect to oils obtained with the traditional technology. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. [Analysis of the results of the SEIMC External Quality Control Program. Year 2012].

    PubMed

    de Gopegui Bordes, Enrique Ruiz; Guna Serrano, M del Remedio; Orta Mira, Nieves; Ovies, María Rosario; Poveda, Marta; Gimeno Cardona, Concepción

    2014-02-01

    The External Quality Control Program of the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC) include controls for bacteriology, serology, mycology, parasitology, mycobacteria, virology and molecular microbiology. This article presents the most relevant conclusions and lessons from the 2012 controls. As a whole, the results obtained in 2012 confirm the excellent skill and good technical standards found in previous editions. However, erroneous results can be obtained in any laboratory and in clinically relevant determinations. Once again, the results of this program highlighted the need to implement both internal and external controls in order to assure the maximal quality of the microbiological tests. Copyright © 2014 Elsevier España, S.L. All rights reserved.

  13. [Analysis of the results of the SEIMC External Quality Control Program. Year 2014].

    PubMed

    Gopegui Bordes, Enrique Ruiz de; Guna Serrano, M Del Remedio; Orta Mira, Nieves; Medina González, Rafael; Rosario Ovies, María; Poveda, Marta; Gimeno Cardona, Concepción

    2016-07-01

    The External Quality Control Program of the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC) include controls for bacteriology, serology, mycology, parasitology, mycobacteria, virology and molecular microbiology. This article presents the most relevant conclusions and lessons from the 2014 controls. As a whole, the results obtained in 2014 confirm the excellent skill and good technical standards found in previous editions. However, erroneous results can be obtained in any laboratory and in clinically relevant determinations. Once again, the results of the SEIMC program highlighted the need to implement both internal and external controls in order to assure the maximal quality of the microbiological tests. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  14. Practical considerations for obtaining high quality quantitative computed tomography data of the skeletal system.

    PubMed

    Troy, Karen L; Edwards, W Brent

    2018-05-01

    Quantitative CT (QCT) analysis involves the calculation of specific parameters such as bone volume and density from CT image data, and can be a powerful tool for understanding bone quality and quantity. However, without careful attention to detail during all steps of the acquisition and analysis process, data can be of poor- to unusable-quality. Good quality QCT for research requires meticulous attention to detail and standardization of all aspects of data collection and analysis to a degree that is uncommon in a clinical setting. Here, we review the literature to summarize practical and technical considerations for obtaining high quality QCT data, and provide examples of how each recommendation affects calculated variables. We also provide an overview of the QCT analysis technique to illustrate additional opportunities to improve data reproducibility and reliability. Key recommendations include: standardizing the scanner and data acquisition settings, minimizing image artifacts, selecting an appropriate reconstruction algorithm, and maximizing repeatability and objectivity during QCT analysis. The goal of the recommendations is to reduce potential sources of error throughout the analysis, from scan acquisition to the interpretation of results. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Improving the quality of parameter estimates obtained from slug tests

    USGS Publications Warehouse

    Butler, J.J.; McElwee, C.D.; Liu, W.

    1996-01-01

    The slug test is one of the most commonly used field methods for obtaining in situ estimates of hydraulic conductivity. Despite its prevalence, this method has received criticism from many quarters in the ground-water community. This criticism emphasizes the poor quality of the estimated parameters, a condition that is primarily a product of the somewhat casual approach that is often employed in slug tests. Recently, the Kansas Geological Survey (KGS) has pursued research directed it improving methods for the performance and analysis of slug tests. Based on extensive theoretical and field research, a series of guidelines have been proposed that should enable the quality of parameter estimates to be improved. The most significant of these guidelines are: (1) three or more slug tests should be performed at each well during a given test period; (2) two or more different initial displacements (Ho) should be used at each well during a test period; (3) the method used to initiate a test should enable the slug to be introduced in a near-instantaneous manner and should allow a good estimate of Ho to be obtained; (4) data-acquisition equipment that enables a large quantity of high quality data to be collected should be employed; (5) if an estimate of the storage parameter is needed, an observation well other than the test well should be employed; (6) the method chosen for analysis of the slug-test data should be appropriate for site conditions; (7) use of pre- and post-analysis plots should be an integral component of the analysis procedure, and (8) appropriate well construction parameters should be employed. Data from slug tests performed at a number of KGS field sites demonstrate the importance of these guidelines.

  16. Optimization of grapevine yield by applying mathematical models to obtain quality wine products

    NASA Astrophysics Data System (ADS)

    Alina, Dobrei; Alin, Dobrei; Eleonora, Nistor; Teodor, Cristea; Marius, Boldea; Florin, Sala

    2016-06-01

    Relationship between the crop load and the grape yield and quality is a dynamic process, specific for wine cultivars and for fresh consumption varieties. Modeling these relations is important for the improvement of technological works. This study evaluated the interrelationship of crop load (B - buds number) and several production parameters (Y - yield; S - sugar; A - acidity; GaI - Glucoacidimetric index; AP - alcoholic potential; F - flavorings, WA - wine alcohol; SR - sugar residue, in Muscat Ottonel wine cultivar and Y - yield; S - sugar; A - acidity; GaI - Glucoacidimetric Index; CP - commercial production; BS - berries size in the Victoria table grape cultivar). In both varieties have been identified correlations between the independent variable (B - buds number as a result of pruning and training practices) and quality parameters analyzed (r = -0.699 for B vsY relationship; r = 0.961 for the relationship B vs S; r = -0.959 for B vs AP relationship; r = 0.743 for the relationship Y vs S, p <0.01, in the Muscat Ottonel cultivar, respectively r = -0.907 for relationship B vs Y; r = -0.975 for B vs CP relationship; r = -0.971 for relationship B vs BS; r = 0.990 for CP vs BS relationship in the Victoria cultivar. Through regression analysis were obtained models that describe the variation concerning production and quality parameters in relation to the independent variable (B - buds number) with statistical significance results.

  17. Yes, one can obtain better quality structures from routine X-ray data collection.

    PubMed

    Sanjuan-Szklarz, W Fabiola; Hoser, Anna A; Gutmann, Matthias; Madsen, Anders Østergaard; Woźniak, Krzysztof

    2016-01-01

    Single-crystal X-ray diffraction structural results for benzidine dihydrochloride, hydrated and protonated N,N,N,N-peri(dimethylamino)naphthalene chloride, triptycene, dichlorodimethyltriptycene and decamethylferrocene have been analysed. A critical discussion of the dependence of structural and thermal parameters on resolution for these compounds is presented. Results of refinements against X-ray data, cut off to different resolutions from the high-resolution data files, are compared to structural models derived from neutron diffraction experiments. The Independent Atom Model (IAM) and the Transferable Aspherical Atom Model (TAAM) are tested. The average differences between the X-ray and neutron structural parameters (with the exception of valence angles defined by H atoms) decrease with the increasing 2θmax angle. The scale of differences between X-ray and neutron geometrical parameters can be significantly reduced when data are collected to the higher, than commonly used, 2θmax diffraction angles (for Mo Kα 2θmax > 65°). The final structural and thermal parameters obtained for the studied compounds using TAAM refinement are in better agreement with the neutron values than the IAM results for all resolutions and all compounds. By using TAAM, it is still possible to obtain accurate results even from low-resolution X-ray data. This is particularly important as TAAM is easy to apply and can routinely be used to improve the quality of structural investigations [Dominiak (2015 ▸). LSDB from UBDB. University of Buffalo, USA]. We can recommend that, in order to obtain more adequate (more accurate and precise) structural and displacement parameters during the IAM model refinement, data should be collected up to the larger diffraction angles, at least, for Mo Kα radiation to 2θmax = 65° (sin θmax/λ < 0.75 Å(-1)). The TAAM approach is a very good option to obtain more adequate results even using data collected to the lower 2θmax angles. Also

  18. [Analysis of the results of the SEIMC External Quality Control Program. Year 2011].

    PubMed

    Ruiz de Gopegui Bordes, Enrique; Guna Serrano, M del Remedio; Orta Mira, Nieves; Ovies, María Rosario; Poveda, Marta; Gimeno Cardona, Concepción

    2013-02-01

    The External Quality Control Program of the Spanish Society of Infectious Diseases and Clinical Microbiology (Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica [SEIMC]) includes controls for bacteriology, serology, mycology, parasitology, mycobacteria, virology, and molecular microbiology. This article presents the most relevant conclusions and lessons from the 2011 controls. Overall, the results obtained in 2011 confirm the excellent skill and good technical standards found in previous years. Nevertheless, erroneous results can be obtained in any laboratory and in clinically relevant determinations. The results of this program highlight the need to implement both internal and external controls, such as those offered by the SEIMC program, in order to ensure maximal quality of microbiological tests. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  19. Analysis of the Quality of Information Obtained About Uterine Artery Embolization From the Internet

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tavare, Aniket N.; Alsafi, Ali, E-mail: ali.alsafi03@imperial.ac.uk; Hamady, Mohamad S.

    Purpose: The Internet is widely used by patients to source health care-related information. We sought to analyse the quality of information available on the Internet about uterine artery embolization (UAE). Materials and Methods: We searched three major search engines for the phrase 'uterine artery embolization' and compiled the top 50 results from each engine. After excluding repeated sites, scientific articles, and links to documents, the remaining 50 sites were assessed using the LIDA instrument, which scores sites across the domains of accessibility, usability, and reliability. The Fleisch reading ease score (FRES) was calculated for each of the sites. Finally, wemore » checked the country of origin and the presence of certification by the Health On the Net Foundation (HONcode) as well as their effect on LIDA and FRES scores.ResultsThe following mean scores were obtained: accessibility 48/60 (80%), usability 42/54 (77%), reliability 20/51 (39%), total LIDA 110/165 (67%), and FRES 42/100 (42%). Nine sites had HONcode certification, and this was associated with significantly greater (p < 0.05) reliability and total LIDA and FRES scores. When comparing sites between United Kingdom and United States, there was marked variation in the quality of results obtained when searching for information on UAE (p < 0.05). Conclusion: In general, sites were well designed and easy to use. However, many scored poorly on the reliability of their information either because they were produced in a non-evidence-based way or because they lacking currency. It is important that patients are guided to reputable, location-specific sources of information online, especially because prominent search engine rank does not guarantee reliability of information.« less

  20. Effects of physical and chemical heterogeneity on water-quality samples obtained from wells

    USGS Publications Warehouse

    Reilly, Thomas E.; Gibs, Jacob

    1993-01-01

    Factors that affect the mass of chemical constituents entering a well include the distributions of flow rate and chemical concentrations along and near the screened or open section of the well. Assuming a layered porous medium (with each layer being characterized by a uniform hydraulic conductivity and chemical concentration), a knowledge of the flow from each layer along the screened zone and of the chemical concentrations in each layer enables the total mass entering the well to be determined. Analyses of hypothetical systems and a site at Galloway, NJ, provide insight into the temporal variation of water-quality data observed when withdrawing water from screened wells in heterogeneous ground-water systems.The analyses of hypothetical systems quantitatively indicate the cause-and-effect relations that cause temporal variability in water samples obtained from wells. Chemical constituents that have relatively uniform concentrations with depth may not show variations in concentrations in the water discharged from a well after the well is purged (evacuation of standing water in the well casing). However, chemical constituents that do not have uniform concentrations near the screened interval of the well may show variations in concentrations in the well discharge water after purging because of the physics of ground-water flow in the vicinity of the screen.Water-quality samples were obtained through time over a 30 minute period from a site at Galloway, NJ. The water samples were analyzed for aromatic hydrocarbons, and the data for benzene, toluene, and meta+para xylene were evaluated for temporal variations. Samples were taken from seven discrete zones, and the flow-weighted concentrations of benzene, toluene, and meta+para xylene all indicate an increase in concentration over time during pumping. These observed trends in time were reproduced numerically based on the estimated concentration distribution in the aquifer and the flow rates from each zone.The results of

  1. Structural dynamic model obtained from flight use with piloted simulation and handling qualities analysis

    NASA Technical Reports Server (NTRS)

    Powers, Bruce G.

    1996-01-01

    The ability to use flight data to determine an aircraft model with structural dynamic effects suitable for piloted simulation. and handling qualities analysis has been developed. This technique was demonstrated using SR-71 flight test data. For the SR-71 aircraft, the most significant structural response is the longitudinal first-bending mode. This mode was modeled as a second-order system, and the other higher order modes were modeled as a time delay. The distribution of the modal response at various fuselage locations was developed using a uniform beam solution, which can be calibrated using flight data. This approach was compared to the mode shape obtained from the ground vibration test, and the general form of the uniform beam solution was found to be a good representation of the mode shape in the areas of interest. To calibrate the solution, pitch-rate and normal-acceleration instrumentation is required for at least two locations. With the resulting structural model incorporated into the simulation, a good representation of the flight characteristics was provided for handling qualities analysis and piloted simulation.

  2. How can we obtain quality controlled sounding data during the YMC campaign?

    NASA Astrophysics Data System (ADS)

    Yoneyama, K.; Bellenger, H.; Nurhayati, N.

    2016-12-01

    Years of the Maritime Continent or YMC is an international field campaign, which aims at enhancing our knowledge of weather-climate systems over the Maritime Continent and its relation to higher latitudes through observations and numerical modeling. It is expected to take place for the period of two years from July 2017. One of the key components of this campaign is a tight relationship with scientists all over the world and the local meteorological agencies. While several intensive observations are designed aiming at specific phenomena such as diurnal cycle of the rainfall, the Madden-Julian Oscillation, and monsoon, long-term measurement done by the local meteorological agencies as their routine basis is also a key to study background atmospheric condition as well as specific phenomena. In particular, radiosonde atmospheric sounding is still the most basic and important observation. While we can obtain data at the conventional heights in near real-time via GTS, original hi-resolution data (1-2 seconds during ascent) will also be available thanks to the great contribution from the local agencies. We must, however, be careful to use those data, since they are obtained under the different conditions with various different radiosonde-types. Even in one country, they adopt different systems due to various reasons. By considering above as well as the necessity of accurate data for analysis, we have started the preparation to produce quality-controlled data. As its first step, since we obtained different radiosonde data (Vaisala RS92, RS41, and Meisei RS-11G) during the pre-YMC campaign done by Japanese and Indonesian groups in November - December 2015, we have developed a correction scheme for them. We also evaluate their accuracy using GPS-derived water vapor. Currently, we are also collecting information for other sites with the help of BMKG for Indonesia (they use Meisei and Modem sensors), MetMalaysia for Malaysia (Changfeng), PAGASA for Philippines (Vaisala

  3. A comparison of defect size and film quality obtained from Film digitized image and digital image radiographs

    NASA Astrophysics Data System (ADS)

    Kamlangkeng, Poramate; Asa, Prateepasen; Mai, Noipitak

    2014-06-01

    Digital radiographic testing is an acceptable premature nondestructive examination technique. Its performance and limitation comparing to the old technique are still not widely well known. In this paper conducted the study on the comparison of the accuracy of the defect size measurement and film quality obtained from film and digital radiograph techniques by testing in specimens and known size sample defect. Initially, one specimen was built with three types of internal defect; which are longitudinal cracking, lack of fusion, and porosity. For the known size sample defect, it was machined various geometrical size for comparing the accuracy of the measuring defect size to the real size in both film and digital images. To compare the image quality by considering at smallest detectable wire and the three defect images. In this research used Image Quality Indicator (IQI) of wire type 10/16 FE EN BS EN-462-1-1994. The radiographic films were produced by X-ray and gamma ray using Kodak AA400 size 3.5x8 inches, while the digital images were produced by Fuji image plate type ST-VI with 100 micrometers resolution. During the tests, a radiator GE model MF3 was implemented. The applied energy is varied from 120 to 220 kV and the current from 1.2 to 3.0 mA. The intensity of Iridium 192 gamma ray is in the range of 24-25 Curie. Under the mentioned conditions, the results showed that the deviation of the defect size measurement comparing to the real size obtained from the digital image radiographs is below than that of the film digitized, whereas the quality of film digitizer radiographs is higher in comparison.

  4. First results obtained within the European 'LAMA' programme (Large Active Mirrors in Aluminium)

    NASA Astrophysics Data System (ADS)

    Rozelot, J.-P.

    1993-11-01

    To investigate the feasibility of large size aluminum mirrors, studies have been undertaken in cooperation with European Southern Observatory (ESO), in the framework of a European program. The first phase, which is just now ended, addressed the following items: (1) tests to select the best aluminum alloy, (2) aluminum welding, homogeneity and stability, (3) aluminum high-precision machining, (4) nickel coating, (5) polishing of the nickel layer, (6) active optics. Furthermore, tests have been conducted to demonstrate that the quality of the mirrors is not altered at various temperatures and after a large number of aluminizing and cleaning cycles (corresponding to about 50 years' life). The mirror shape (whose specifications are fully compliant with those of the Very Large Telescope (VLT), as the program is conducted in cooperation with ESO) was computed under several causes of deformations: evidencing gravity as the predominant effect, and very low distortions as the high thermal conductivity limits the thermal transverse gradient to 0.025 C. Results show that it is quite possible to obtain high optical quality mirrors, mainly due to recent progress both in metallurgical processes (high precision machining -7 microns rms-) and active optics, that permit to correct residual aberrations of the surface. Such an alternative to classical glass mirrors will presently stand as a safe, economical solution that saves manufacturing time, for monolithic or segmented mirrors for innovative telescopes (e.g., lunar interferometric network).

  5. Comparison of Anaerobic Susceptibility Results Obtained by Different Methods

    PubMed Central

    Rosenblatt, J. E.; Murray, P. R.; Sonnenwirth, A. C.; Joyce, J. L.

    1979-01-01

    Susceptibility tests using 7 antimicrobial agents (carbenicillin, chloramphenicol, clindamycin, penicillin, cephalothin, metronidazole, and tetracycline) were run against 35 anaerobes including Bacteroides fragilis (17), other gram-negative bacilli (7), clostridia (5), peptococci (4), and eubacteria (2). Results in triplicate obtained by the microbroth dilution method and the aerobic modification of the broth disk method were compared with those obtained with an agar dilution method using Wilkins-Chalgren agar. Media used in the microbroth dilution method included Wilkins-Chalgren broth, brain heart infusion broth, brucella broth, tryptic soy broth, thioglycolate broth, and Schaedler's broth. A result differing by more than one dilution from the Wilkins-Chalgren agar result was considered a discrepancy, and when there was a change in susceptibility status this was termed a significant discrepancy. The microbroth dilution method using Wilkins-Chalgren broth and thioglycolate broth produced the fewest total discrepancies (22 and 24, respectively), and Wilkins-Chalgren broth, thioglycolate, and Schaedler's broth had the fewest significant discrepancies (6, 5, and 5, respectively). With the broth disk method, there were 15 significant discrepancies, although half of these were with tetracycline, which was the antimicrobial agent associated with the highest number of significant discrepancies (33), considering all of the test methods and media. PMID:464560

  6. Optimization of Pumpkin Oil Recovery by Using Aqueous Enzymatic Extraction and Comparison of the Quality of the Obtained Oil with the Quality of Cold-Pressed Oil

    PubMed Central

    Roszkowska, Beata; Czaplicki, Sylwester; Tańska, Małgorzata

    2016-01-01

    Summary The study was carried out to optimize pumpkin oil recovery in the process of aqueous extraction preceded by enzymatic maceration of seeds, as well as to compare the quality of the obtained oil to the quality of cold-pressed pumpkin seed oil. Hydrated pulp of hulless pumpkin seeds was macerated using a 2% (by mass) cocktail of commercial pectinolytic, cellulolytic and proteolytic preparations (Rohapect® UF, Rohament® CL and Colorase® 7089). The optimization procedure utilized response surface methodology based on Box- -Behnken plan of experiment. The optimized variables of enzymatic pretreatment were pH, temperature and maceration time. The results showed that the pH value, temperature and maceration time of 4.7, 54 °C and 15.4 h, respectively, were conducive to maximize the oil yield up to 72.64%. Among these variables, the impact of pH was crucial (above 73% of determined variation) for oil recovery results. The oil obtained by aqueous enzymatic extraction was richer in sterols, squalene and tocopherols, and only slightly less abundant in carotenoids than the cold-pressed one. However, it had a lower oxidative stability, with induction period shortened by approx. 30% in relation to the cold-pressed oil. PMID:28115898

  7. Quality of non-mydriatic digital fundus photography obtained by nurse practitioners in the emergency department: the FOTO-ED study

    PubMed Central

    Lamirel, Cédric; Bruce, Beau B.; Wright, David W.; Delaney, Kevin P.; Newman, Nancy J.; Biousse, Valérie

    2011-01-01

    Objective Non-mydriatic fundus photography by non-ophthalmic trained personnel has recently been shown to be a potential alternative to direct ophthalmoscopy in the emergency department (ED). We evaluated the reliability of a novel quality rating scale and applied this scale to non-mydriatic fundus photographs taken during routine ED patient encounters to determine factors associated with diminished photograph quality. Design Prospective, cross-sectional Participants 350 patients enrolled in the Fundus photography vs. Ophthalmoscopy Trials Outcomes in the Emergency Department (FOTO-ED) study were photographed by nurse practitioners after <30 minutes of training followed by supervision. Methods Photographs of both eyes were graded for quality on two occasions by two neuro-ophthalmologists. Four regions were independently evaluated for quality: optic disc, macula, superior and inferior vascular arcades. Quality as a function of the number of photographs taken was evaluated by Kaplan-Meier analysis. Mixed effects ordinal logistic regression was used to evaluate for predictors of image quality while accounting for the repeated measures design. Main Outcome Measure Overall photographic quality (1–5 scale, 5 best). Results We evaluated 1734 photographs. Inter- and intra-observer agreements between neuro-ophthalmologists were very good (weighted kappa:0.84–0.87). Quality of the optic disc area was better than those of other retinal areas (p<0.002). Kaplan-Meier analysis showed that if a high-quality photograph of an eye was not obtained by the third attempt it was unlikely that one would be obtained at all. A 10 second increase in the inter-photograph interval before a total of forty seconds increased the odds of a one unit higher quality rating by 1.81 times (95%CI: 1.68–1.98), and a ten year increase in age decreased the odds by 0.76 times (95%CI: 0.69–0.85). Black patients had 0.42 times (95%CI: 0.28–0.63) the odds of a one unit higher quality rating compared

  8. The quality of Medicaid and Medicare data obtained from CMS and its contractors: implications for pharmacoepidemiology.

    PubMed

    Leonard, Charles E; Brensinger, Colleen M; Nam, Young Hee; Bilker, Warren B; Barosso, Geralyn M; Mangaali, Margaret J; Hennessy, Sean

    2017-04-26

    Administrative claims of United States Centers for Medicare and Medicaid Services (CMS) beneficiaries have long been used in non-experimental research. While CMS performs in-house checks of these claims, little is known of their quality for conducting pharmacoepidemiologic research. We performed exploratory analyses of the quality of Medicaid and Medicare data obtained from CMS and its contractors. Our study population consisted of Medicaid beneficiaries (with and without dual coverage by Medicare) from California, Florida, New York, Ohio, and Pennsylvania. We obtained and compiled 1999-2011 data from these state Medicaid programs (constituting about 38% of nationwide Medicaid enrollment), together with corresponding national Medicare data for dually-enrolled beneficiaries. This descriptive study examined longitudinal patterns in: dispensed prescriptions by state, by quarter; and inpatient hospitalizations by federal benefit, state, and age group. We further examined discrepancies between demographic characteristics and disease states, in particular frequencies of pregnancy complications among men and women beyond childbearing age, and prostate cancers among women. Dispensed prescriptions generally increased steadily and consistently over time, suggesting that these claims may be complete. A commercially-available National Drug Code lookup database was able to identify the dispensed drug for 95.2-99.4% of these claims. Because of co-coverage by Medicare, Medicaid data appeared to miss a substantial number of hospitalizations among beneficiaries ≥ 45 years of age. Pregnancy complication diagnoses were rare in males and in females ≥ 60 years of age, and prostate cancer diagnoses were rare in females. CMS claims from five large states obtained directly from CMS and its contractors appeared to be of high quality. Researchers using Medicaid data to study hospital outcomes should obtain supplemental Medicare data on dual enrollees, even for non-elders. Not

  9. Evaluation of quality of kefir from milk obtained from goats supplemented with a diet rich in bioactive compounds.

    PubMed

    Cais-Sokolińska, Dorota; Pikul, Jan; Wójtowski, Jacek; Danków, Romualda; Teichert, Joanna; Czyżak-Runowska, Grażyna; Bagnicka, Emilia

    2015-04-01

    The composition of bioactive components in dairy products depends on their content in raw milk and the processing conditions. The experimental material consisted of the milk of dairy goats supplemented with 120 g d(-1) per head of false flax cake. The aim of the study was to evaluate the quality of kefir produced from goat's milk with a higher content of bioactive components resulting from supplementation of the goats' diet with false flax cake. The administration of false flax cake to goats had a positive effect on the fatty acid profile of the raw milk, causing an increase in the proportion of polyunsaturated fatty acids (PUFA), including conjugated linoleic acid (CLA) and n-3 fatty acids. Their increased percentage was detected in the kefir after production as well as after storage. The processing value of the harvested milk did not differ from the qualitative characteristics of milk from goats of the control group. Increasing the proportion of bioactive components in goat's milk did not result in changes in the acidity, texture, colour, flavour, aroma or consistency of the kefir obtained. Milk and kefir obtained after the administration of false flax cake to goats contain bioactive components (PUFA including CLA, n-3 and monoenic trans fatty acids) in significant amounts. Kefir from experimental goat's milk did not differ in quality from kefir made from the milk of the control group. © 2014 Society of Chemical Industry.

  10. Financial and quality-of-life burden of dysfunctional uterine bleeding among women agreeing to obtain surgical treatment.

    PubMed

    Frick, Kevin D; Clark, Melissa A; Steinwachs, Donald M; Langenberg, Patricia; Stovall, Dale; Munro, Malcolm G; Dickersin, Kay

    2009-01-01

    In this study, we sought to 1) describe elements of the financial and quality-of-life burden of dysfunctional uterine bleeding (DUB) from the perspective of women who agreed to obtain surgical treatment; 2) explore associations between DUB symptom characteristics and the financial and quality-of-life burden; 3) estimate the annual dollar value of the financial burden; and 4) estimate the most that could be spent on surgery to eliminate DUB symptoms for which medical treatment has been unsuccessful that would result in a $50,000/quality-adjusted life-year incremental cost-effectiveness ratio. We collected baseline data on DUB symptoms and aspects of the financial and quality-of-life burden for 237 women agreeing to surgery for DUB in a randomized trial comparing hysterectomy with endometrial ablation. Measures included out-of-pocket pharmaceutical expenditures, excess expenditures on pads or tampons, the value of time missed from paid work and home management activities, and health utility. We used chi2 and t tests to assess the statistical significance of associations between DUB characteristics and the financial and quality-of-life burden. The annual financial burden was estimated. Pelvic pain and cramps were associated with activity limitations and tiredness was associated with a lower health utility. Excess pharmaceutical and pad and tampon costs were $333 per patient per year (95% confidence interval [CI], $263-$403). Excess paid work and home management loss costs were $2,291 per patient per year (95% CI, $1847-$2752). Effective surgical treatment costing $40,000 would be cost-effective compared with unsuccessful medical treatment. The financial and quality-of-life effects of DUB represent a substantial burden.

  11. Quality circles: Organizational adaptations, improvements and results

    NASA Technical Reports Server (NTRS)

    Tortorich, R.

    1985-01-01

    The effective application in industry and government of quality circles work was demonstrated. The results achieved in quality and productivity improvements and cost savings are impressive. The circle process should be institutionalized within industry and government. The stages of circle program growth, innovations that help achieve circle process institutionalization, and the result achieved at Martin Marietta's Michoud Division and within the National Aeronautics and Space Administration (NASA) are addressed.

  12. Discrimination of the sensory quality of the Coffea arabica L. (cv. Yellow Bourbon) produced in different altitudes using decision trees obtained by the CHAID method.

    PubMed

    Ramos, Mariana Figueira; Ribeiro, Diego Egídio; Cirillo, Marcelo Ângelo; Borém, Flávio Meira

    2016-08-01

    Knowledge of the sensory profile of coffee quality, associated with genetic and environmental factors, is of utmost importance for the international market, as well as for the productive sector. In this context, the goal of this study was to classify the quality of Coffea arabica L., cv. Yellow Bourbon, according to different scores obtained through sensory evaluations based on the Specialty Coffee Association of America protocol (SCAA), and by means of decision trees resulting from applying the CHAID method (chi-square automatic interaction detection). To that end, we used a database with the sensory characteristics of cv. Yellow Bourbon and the environmental characteristics of the Mantiqueira de Minas region, State of Minas Gerais, Brazil. The method used exhibited promising results regarding accuracy and success rates in order to discriminate coffee sensory quality as a function of the production environment. The results obtained clearly show the effect of the coffee growing environment on the Yellow Bourbon variety, resulting in notable sensory differences in the beverage. It was possible to discriminate cv. Yellow Bourbon coffee samples, the sensory evaluations of which resulted in scores of ≥88 points, which are associated with growing environments at altitudes of ≥1200 m. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.

  13. Effect of geometrical features various objects on the data quality obtained with measured by TLS

    NASA Astrophysics Data System (ADS)

    Pawłowicz, J. A.

    2017-08-01

    Collecting data on different building structures using Terrestrial Laser Scanning (TLS) has become in recent years a very popular due to minimize the time required to complete the task as compared to traditional methods. Technical parameters of 3D scanning devices (digitizers) are increasingly being improved, and the accuracy of the data collected allows you to play not only the geometry of an existing object in a digital image, but also enables the assessment of his condition. This is possible thanks to the digitalization of existing objects e.g., a 3D laser scanner, with which is obtained a digital data base is presented in the form of a cloud of points and by using reverse engineering. Measurements using laser scanners depends to a large extent, on the quality of the returning beam reflected from the target surface, towards the receiver. High impact on the strength and quality of the beam returning to the geometric features of the object. These properties may contribute to the emergence of some, sometimes even serious errors during scanning of various shapes. The study defined the effect of the laser beam distortion during the measurement objects with the same material but with different geometrical features on their three-dimensional imaging obtained from measurements made using TLS. We present the problem of data quality, dependent on the deflection of the beam intensity and shape of the object selected examples. The knowledge of these problems allows to obtain valuable data necessary for the implementation of digitization and the visualization of virtually any building structure made of any materials. The studies has been proven that the increase in the density of scanning does not affect the values of mean square error. The increase in the angle of incidence of the beam onto a flat surface, however, causes a decrease in the intensity of scattered radiation that reaches the receiver. The article presents an analysis of the laser beam reflected from broken at

  14. Marital quality and diabetes: results from the Health and Retirement Study.

    PubMed

    Whisman, Mark A; Li, Angela; Sbarra, David A; Raison, Charles L

    2014-08-01

    Poor marital quality is associated with many different indicators of poor health, including immunologic and metabolic responses that have relevance for distal disease outcomes such as diabetes. We conducted this study to evaluate whether poor marital quality was associated with the prevalence of diabetes in a population-based sample of Americans over the age of 50. Participants were married adults from the 2006 (N = 3,898) and 2008 (N = 3,452) waves of the Health and Retirement Study. Participants completed an interview and a self-report questionnaire, and current use of diabetes medication and glycosylated hemoglobin obtained from blood spot samples were used to index diabetes status. Marital quality was assessed with items regarding perceived frequency of positive and negative exchanges with partner. Decreasing frequency of positive exchanges and increasing frequency of negative exchanges with one's spouse were associated with higher prevalence of diabetes among men, but not women at both waves; gender significantly moderated the associations between partner exchanges and diabetes status for the 2006 data. The association between frequency of partner exchanges and diabetes status generally remained significant in men after accounting for demographic characteristics and other risk factors (obesity, hypertension, low physical activity). Poor marital quality as operationalized by rates of positive and negative partner exchanges was associated with increased prevalence of diabetes in men. These results are consistent with prior work on marriage and health, and suggest that poor marital quality may be a unique risk factor for diabetes.

  15. [Analysis of the results of the SEIMC External Quality Control Program for HIV-1 and HCV viral loads. Year 2008].

    PubMed

    Mira, Nieves Orta; Serrano, María del Remedio Guna; Martínez, José Carlos Latorre; Ovies, María Rosario; Pérez, José L; Cardona, Concepción Gimeno

    2010-01-01

    Human immunodeficiency virus type 1 (HIV-1) and hepatitis C virus (HCV) viral load determinations are among the most relevant markers for the follow up of patients infected with these viruses. External quality control tools are crucial to ensure the accuracy of results obtained by microbiology laboratories. This article summarized the results obtained from the 2008 SEIMC External Quality Control Program for HIV-1 and HCV viral loads. In the HIV-1 program, a total of five standards were sent. One standard consisted in seronegative human plasma, while the remaining four contained plasma from 3 different viremic patients, in the range of 2-5 log(10) copies/mL; two of these standards were identical aiming to determine repeatability. The specificity was complete for all commercial methods, and no false positive results were reported by the participants. A significant proportion of the laboratories (24% on average) obtained values out of the accepted range (mean +/- 0.2 log(10) copies/mL), depending on the standard and on the method used for quantification. Repeatability was very good, with up to 95% of laboratories reporting results within the limits (D < 0.5 log(10) copias/mL). The HCV program consisted of two standards with different viral load contents. Most of the participants (88,7%) obtained results within the accepted range (mean +/- 1.96 SD log(10) UI/mL). Post-analytical errors due to mistranscription of the results were detected for HCV, but not for the HIV-1 program. Data from this analysis reinforce the utility of proficiency programmes to ensure the quality of the results obtained by a particular laboratory, as well as the importance of the post-analytical phase on the overall quality. Due to the remarkable interlaboratory variability, it is advisable to use the same method and the same laboratory for patient follow up. 2010 Elsevier España S.L. All rights reserved.

  16. Effect of grape pomace extracts obtained from different grape varieties on microbial quality of beef patty.

    PubMed

    Sagdic, Osman; Ozturk, Ismet; Yilmaz, Mustafa Tahsin; Yetim, Hasan

    2011-09-01

    Grape pomace extracts were obtained from 5 different grape varieties grown in Turkey. The extracts were concentrated to obtain crude extracts; and incorporated into beef patties at 0% (Control), 1%, 2%, 5%, and 10% concentrations to test their antimicrobial effects in different storage periods (first, 12, 24, and 48 h). The numbers of microorganism were generally decreased by the extract concentration during the storage period. All the microorganisms tested were inhibited by the extract concentration of 10% in all the storage periods. Furthermore, the foodborne pathogens including Enterobacteriaceae and coliform bacteria, and the spoilage microorganisms including yeasts and moulds and lipolytic bacteria were also inhibited by 5% of Emir, Gamay, and Kalecik Karasi varieties in beef patties. Considering the results, the extracts of grape pomaces might be a good choice in the microbial shelf life extension of the food products as well as inhibiting the food pathogens as the case of beef patties. Grape pomace consists of seeds, skins, and stems, and an important by-product that is well known to be the rich source of phenolic compounds, both flavonoids and non-flavonoids. These substances have considerable beneficial effects on human health. The use of natural antimicrobial compounds, like plant extracts of herbs and spices for the preservation of foods has been very popular issue because of their antimicrobial activity. Therefore, grape pomace should be added into some food formulations to benefit from their protective effects. In this respect, this study reports the effect of addition of grape pomace extracts obtained from different grape varieties on microbial quality of beef patty. The results obtained in this study may be useful for food industry, which has recently tended to use natural antimicrobial sources in place of synthetic preservatives to prevent microbial spoilage. © 2011 Institute of Food Technologists®

  17. 42 CFR 438.364 - External quality review results.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 4 2011-10-01 2011-10-01 false External quality review results. 438.364 Section 438.364 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... quality review results. (a) Information that must be produced. The State must ensure that the EQR produces...

  18. 42 CFR 438.364 - External quality review results.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 4 2013-10-01 2013-10-01 false External quality review results. 438.364 Section 438.364 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... quality review results. (a) Information that must be produced. The State must ensure that the EQR produces...

  19. 42 CFR 438.364 - External quality review results.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 4 2014-10-01 2014-10-01 false External quality review results. 438.364 Section 438.364 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... quality review results. (a) Information that must be produced. The State must ensure that the EQR produces...

  20. 42 CFR 438.364 - External quality review results.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 4 2012-10-01 2012-10-01 false External quality review results. 438.364 Section 438.364 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... quality review results. (a) Information that must be produced. The State must ensure that the EQR produces...

  1. 42 CFR 438.364 - External quality review results.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false External quality review results. 438.364 Section 438.364 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... quality review results. (a) Information that must be produced. The State must ensure that the EQR produces...

  2. [Analysis of the results of the HIV-1, HCV and HBV viral load of SEIMC External Quality Control Program. Year 2013].

    PubMed

    Orta Mira, Nieves; Del Remedio Guna Serrano, María; Latorre Martínez, José-Carlos; Medina González, Rafael; Rosario Ovies, María; Poveda, Marta; Ruiz de Gopegui, Enrique; Gimeno Cardona, Concepción

    2015-07-01

    Human immunodeficiency virus type 1 (HIV-1) and hepatitis B (HBV) and C virus (HCV) viral load determinations are among the most relevant markers for the follow up of patients infected with these viruses. External quality control tools are crucial to ensure the accuracy of results obtained by microbiology laboratories. This article summarized the results obtained from the 2013 SEIMC External Quality Control Programme for HIV-1, HCV, and HBV viral loads. In the HIV-1 program, a total of five standards were sent. One standard consisted in seronegative human plasma, while the remaining four contained plasma from three different viremic patients, in the range of 2-5 log10 copies/mL; two of these standards were identical aiming to determine repeatability. A significant proportion of the laboratories (25% on average) obtained values out of the accepted range (mean ± 0.25 log10 copies/mL), depending on the standard and on the method used for quantification. Repeatability was excellent, with up to 98.9% of laboratories reporting results within the limits (D < 0.5 log10 copies/mL). The HBV and HCV program consisted of two standards with different viral load contents. Most of the participants, 82% in the case of HCV and 78% in the HBV, obtained all the results within the accepted range (mean ± 1.96 SD log10 UI/mL). Data from this analysis reinforce the utility of proficiency programmes to ensure the quality of the results obtained by a particular laboratory, as well as the importance of the post-analytical phase on the overall quality. Due to the remarkable interlaboratory variability, it is advisable to use the same method and the same laboratory for patient follow up. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  3. [Analysis of the results of the 2010 External Quality Control Program of the Spanish Society of Infectious Diseases and Clinical Microbiology].

    PubMed

    Ruiz de Gopegui Bordes, Enrique; Serrano, M del Remedio Guna; Orta Mira, Nieves; Ovies, María Rosario; Poveda, Marta; Cardona, Concepción Gimeno

    2011-12-01

    The External Quality Control Program of the Spanish Society of Infectious Diseases and Clinical Microbiology includes controls for bacteriology, serology, mycology, parasitology, mycobacteria, virology and molecular microbiology. This article presents the most important conclusions and lessons of the 2010 controls. As a whole, the results obtained in 2010 confirm the excellent skill and good technical standards found in previous years. However, erroneous results can be obtained in any laboratory and in clinically relevant determinations. The results of this program highlight the need to implement both internal and external controls to ensure maximal quality of microbiological tests(1). Copyright © 2011 Elsevier España S.L. All rights reserved.

  4. The best choice of equipment to obtain high quality standardised results in intra-oral photography - a comparison between the common practice in the UK and the gold standard set by the literature.

    PubMed

    Marcato, Laura; Sandler, Jonathan

    2018-04-01

    Since digital technology made dental photography widely available, photographers have been trying to establish the 'gold standard' when obtaining intra-oral photographs. A basic knowledge of photographic principles, familiarity with particular dental techniques and a correct choice and use of equipment contribute significantly both to the standardisation and quality of photographs. A recent survey between members of the Institute of Medical Illustrators shed a light on the current practice in the UK. Medical photographers do not always have access to the full range of suitable equipment. A better selection of retractors and occlusal mirrors would undoubtedly contribute to higher quality images.

  5. Modelled air pollution levels versus EC air quality legislation - results from high resolution simulation.

    PubMed

    Chervenkov, Hristo

    2013-12-01

    An appropriate method for evaluating the air quality of a certain area is to contrast the actual air pollution levels to the critical ones, prescribed in the legislative standards. The application of numerical simulation models for assessing the real air quality status is allowed by the legislation of the European Community (EC). This approach is preferable, especially when the area of interest is relatively big and/or the network of measurement stations is sparse, and the available observational data are scarce, respectively. Such method is very efficient for similar assessment studies due to continuous spatio-temporal coverage of the obtained results. In the study the values of the concentration of the harmful substances sulphur dioxide, (SO2), nitrogen dioxide (NO2), particulate matter - coarse (PM10) and fine (PM2.5) fraction, ozone (O3), carbon monoxide (CO) and ammonia (NH3) in the surface layer obtained from modelling simulations with resolution 10 km on hourly bases are taken to calculate the necessary statistical quantities which are used for comparison with the corresponding critical levels, prescribed in the EC directives. For part of them (PM2.5, CO and NH3) this is done for first time with such resolution. The computational grid covers Bulgaria entirely and some surrounding territories and the calculations are made for every year in the period 1991-2000. The averaged over the whole time slice results can be treated as representative for the air quality situation of the last decade of the former century.

  6. [Analysis of the results of the HIV-1, HCV and HBV viral load of SEIMC External Quality Control Program. Year 2014].

    PubMed

    Medina González, Rafael; Orta Mira, Nieves; Guna Serrano, María Del Remedio; Latorre Martínez, José-Carlos; Gopegui, Enrique Ruiz de; Rosario Ovies, María; Poveda, Marta; Gimeno Cardona, Concepción

    2016-07-01

    Human immunodeficiency virus type 1 (HIV-1), hepatitis B virus (HBV) and hepatitis C virus (HCV) viral load determinations are among the most relevant markers for the follow up of patients infected with these viruses. External quality control tools are crucial to ensure the accuracy of results obtained by microbiology laboratories. This article summarizes the results obtained from the 2014 SEIMC (Spanish Society of Infectious Diseases and Clinical Microbiology) External Quality Control Programme for HIV-1, HCV, and HBV viral loads. In the HIV-1 program, a total of 5 standards were sent. One standard consisted in seronegative human plasma, while the remaining 4 contained plasma from 3 different viremic patients, in the range of 2-5 log10 copies/mL; 2 of these standards were identical aiming to determine repeatability. A significant proportion of the laboratories (30.8% on average) obtained values out of the accepted range (mean ± 0.25 log10 copies/mL), depending on the standard and on the method used for quantification. Repeatability was excellent, with up to 95.8% of laboratories reporting results within the limits (Δ < 0.5 log10 copies/mL). The HBV and HCV program consisted of 2 standards with different viral load contents. Most of the participants, 83.7% in the case of HCV and 87.9% in the HBV, obtained all the results within the accepted range (mean ± 1.96 standard deviations log10 IU/mL). Data from this analysis reinforce the utility of proficiency programmes to ensure the quality of the results obtained by a particular laboratory, as well as the importance of the post-analytical phase on the overall quality. Due to the remarkable interlaboratory variability, it is advisable to use the same method and the same laboratory for patient follow up. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  7. New Quality Metrics for Web Search Results

    NASA Astrophysics Data System (ADS)

    Metaxas, Panagiotis Takis; Ivanova, Lilia; Mustafaraj, Eni

    Web search results enjoy an increasing importance in our daily lives. But what can be said about their quality, especially when querying a controversial issue? The traditional information retrieval metrics of precision and recall do not provide much insight in the case of web information retrieval. In this paper we examine new ways of evaluating quality in search results: coverage and independence. We give examples on how these new metrics can be calculated and what their values reveal regarding the two major search engines, Google and Yahoo. We have found evidence of low coverage for commercial and medical controversial queries, and high coverage for a political query that is highly contested. Given the fact that search engines are unwilling to tune their search results manually, except in a few cases that have become the source of bad publicity, low coverage and independence reveal the efforts of dedicated groups to manipulate the search results.

  8. Trained nurses can obtain satisfactory bone marrow aspirates and trephine biopsies.

    PubMed Central

    Lawson, S; Aston, S; Baker, L; Fegan, C D; Milligan, D W

    1999-01-01

    AIMS: To assess the feasibility of training nurse practitioners to perform bone marrow aspiration and trephine biopsy, and to compare the quality of these samples with those obtained by medical staff. METHODS: A retrospective audit was undertaken of nurse practitioner and medical staff performance in bone marrow procedures in a busy haematology day unit. RESULTS: Nurse practitioners fared favourably in comparison with medical staff in performing bone marrow trephine biopsies, with mean biopsy lengths of 11 mm and 10.7 mm respectively. However, only 78% of the smears obtained by the nurses were judged technically satisfactory, compared with 91% prepared by doctors. This discrepancy was thought to be due largely to the quality of slide spreading. CONCLUSIONS: With motivated staff and a structured educational and training programme it is possible for nurse practitioners to perform the techniques of bone marrow aspiration and biopsy, and obtain specimens of satisfactory quality, thus improving efficiency of the haematology day unit and increasing quality of patient care. Images PMID:10396248

  9. An innovative recycling process to obtain pure polyethylene and polypropylene from household waste.

    PubMed

    Serranti, Silvia; Luciani, Valentina; Bonifazi, Giuseppe; Hu, Bin; Rem, Peter C

    2015-01-01

    An innovative recycling process, based on magnetic density separation (MDS) and hyperspectral imaging (HSI), to obtain high quality polypropylene and polyethylene as secondary raw materials, is presented. More in details, MDS was applied to two different polyolefin mixtures coming from household waste. The quality of the two separated PP and PE streams, in terms of purity, was evaluated by a classification procedure based on HSI working in the near infrared range (1000-1700 nm). The classification model was built using known PE and PP samples as training set. The results obtained by HSI were compared with those obtained by classical density analysis carried in laboratory on the same polymers. The results obtained by MDS and the quality assessment of the plastic products by HSI showed that the combined action of these two technologies is a valid solution that can be implemented at industrial level. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Toward Obtaining Reliable Particulate Air Quality Information from Satellites

    NASA Astrophysics Data System (ADS)

    Strawa, A. W.; Chatfield, R. B.; Legg, M.; Esswein, R.; Justice, E.

    2009-12-01

    Air quality agencies use ground sites to monitor air quality, providing accurate information at particular points. Using measurements from satellite imagery has the potential to provide air quality information in a timely manner with better spatial resolution and at a lower cost that can also useful for model validation. While previous studies show acceptable correlations between Aerosol Optical Depth (AOD) derived from MODIS and surface Particulate Matter (PM) measurements on the eastern US, the data do not correlate well in the western US (Al-Saadi et al., 2005; Engle-Cox et al., 2004) . This paper seeks to improve the AOD-PM correlations by using advanced statistical analysis techniques. Our study area is the San Joaquin Valley in California because air quality in this region has failed to meet state and federal attainment standards for PM for the past several years. A previous investigation found good correlation of the AOD values between MODIS, MISR and AERONET, but poor correlations (R2 ~ 0.02) between satellite-based AOD and surface PM2.5 measurements. PM2.5 measurements correlated somewhat better (R2 ~ 0.18) with MODIS-derived AOD using the Deep Blue surface reflectance algorithm (Hsu et al., 2006) rather than the standard MODIS algorithm. This level of correlation is not adequate for reliable air quality measurements. Pelletier et al. (2007) used generalized additive models (GAMs) and meteorological data to improve the correlation between PM and AERONET AOD in western Europe. Additive models are more flexible than linear models and the functional relationships can be plotted to give a sense of the relationship between the predictor and the response. In this paper we use GAMs to improve surface PM2.5 to MODIS-AOD correlations. For example, we achieve an R2 ~ 0.44 using a GAM that includes the Deep Blue AOD, and day of year as parameters. Including NOx observations, improves the R2 ~ 0.64. Surprisingly Ångström exponent did not prove to be a significant

  11. International normalized ratio (INR) testing in Europe: between-laboratory comparability of test results obtained by Quick and Owren reagents.

    PubMed

    Meijer, Piet; Kynde, Karin; van den Besselaar, Antonius M H P; Van Blerk, Marjan; Woods, Timothy A L

    2018-04-12

    This study was designed to obtain an overview of the analytical quality of the prothrombin time, reported as international normalized ratio (INR) and to assess the variation of INR results between European laboratories, the difference between Quick-type and Owren-type methods and the effect of using local INR calibration or not. In addition, we assessed the variation in INR results obtained for a single donation in comparison with a pool of several plasmas. A set of four different lyophilized plasma samples were distributed via national EQA organizations to participating laboratories for INR measurement. Between-laboratory variation was lower in the Owren group than in the Quick group (on average: 6.7% vs. 8.1%, respectively). Differences in the mean INR value between the Owren and Quick group were relatively small (<0.20 INR). Between-laboratory variation was lower after local INR calibration (CV: 6.7% vs. 8.6%). For laboratories performing local calibration, the between-laboratory variation was quite similar for the Owren and Quick group (on average: 6.5% and 6.7%, respectively). Clinically significant differences in INR results (difference in INR>0.5) were observed between different reagents. No systematic significant differences in the between-laboratory variation for a single-plasma sample and a pooled plasma sample were observed. The comparability for laboratories using local calibration of their thromboplastin reagent is better than for laboratories not performing local calibration. Implementing local calibration is strongly recommended for the measurement of INR.

  12. Instructor Quality and EMT Certification Examination Results

    ERIC Educational Resources Information Center

    Russ-Eft, Darlene; Dickison, Phil; Levine, Roger

    2007-01-01

    The Longitudinal Emergency Medical Technician Attributes and Demographics Study (LEADS) provides a representative sampling of EMTs throughout the United States. This study examines the relationship between instructor quality and National Registry of Emergency Medical Technicians certification examination outcomes. Results show significant…

  13. Aerodynamic Characteristics and Flying Qualities of a Tailless Triangular-wing Airplane Configuration as Obtained from Flights of Rocket-propelled Models at Transonic and Supersonic Speeds

    NASA Technical Reports Server (NTRS)

    Mitcham, Grady L; Stevens, Joseph E; Norris, Harry P

    1956-01-01

    A flight investigation of rocket-powered models of a tailless triangular-wing airplane configuration was made through the transonic and low supersonic speed range at the Langley Pilotless Aircraft Research Station at Wallops Island, Va. An analysis of the aerodynamic coefficients, stability derivatives, and flying qualities based on the results obtained from the successful flight tests of three models is presented.

  14. Influence of air quality on the results of in vitro fertilization attempts: A retrospective study.

    PubMed

    Carré, Julie; Gatimel, Nicolas; Moreau, Jessika; Parinaud, Jean; Leandri, Roger

    2017-03-01

    To assess the influence of air quality on the results of IVF. We performed a retrospective study on 292 patients who have undergone an IVF attempt from April 2012 to December 2015 in our French university hospital. Patients were included in the study if data on the air quality at home and at work were available and if they haven't been gone for more than 4days in a month. Data were recorded during the 3 months before oocyte collection and 1 month after embryo transfer. Air quality measurements were obtained from the Observatoire Régional de l'Air en Midi-Pyrénées (ORAMIP) and concerned the levels of nitrogen dioxide (NO 2 ), ozone (O 3 ), particulate matter PM10 and SO 2 measured every day. Acute exposures to high levels NO 2 or PM10 were associated with lower results of IVF (ovarian response to stimulation, number of top embryos) while these parameters were enhanced when patients were exposed to high levels of O 3 during the first 2 months of folliculogenesis. These effects were found even for a short exposure (1day). Air quality has an impact on global health and also on the reproductive function and public and authorities must be aware of environmental protection. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Proteomics Quality Control: Quality Control Software for MaxQuant Results.

    PubMed

    Bielow, Chris; Mastrobuoni, Guido; Kempa, Stefan

    2016-03-04

    Mass spectrometry-based proteomics coupled to liquid chromatography has matured into an automatized, high-throughput technology, producing data on the scale of multiple gigabytes per instrument per day. Consequently, an automated quality control (QC) and quality analysis (QA) capable of detecting measurement bias, verifying consistency, and avoiding propagation of error is paramount for instrument operators and scientists in charge of downstream analysis. We have developed an R-based QC pipeline called Proteomics Quality Control (PTXQC) for bottom-up LC-MS data generated by the MaxQuant software pipeline. PTXQC creates a QC report containing a comprehensive and powerful set of QC metrics, augmented with automated scoring functions. The automated scores are collated to create an overview heatmap at the beginning of the report, giving valuable guidance also to nonspecialists. Our software supports a wide range of experimental designs, including stable isotope labeling by amino acids in cell culture (SILAC), tandem mass tags (TMT), and label-free data. Furthermore, we introduce new metrics to score MaxQuant's Match-between-runs (MBR) functionality by which peptide identifications can be transferred across Raw files based on accurate retention time and m/z. Last but not least, PTXQC is easy to install and use and represents the first QC software capable of processing MaxQuant result tables. PTXQC is freely available at https://github.com/cbielow/PTXQC .

  16. Obtaining patient test results from clinical laboratories: a survey of state law for pharmacists.

    PubMed

    Witry, Matthew J; Doucette, William R

    2009-01-01

    To identify states with laws that restrict to whom clinical laboratories may release copies of laboratory test results and to describe how these laws may affect pharmacists' ability to obtain patient laboratory test results. Researchers examined state statutes and administrative codes for all 50 states and the District of Columbia at the University of Iowa Law Library between June and July 2007. Researchers also consulted with lawyers, state Clinical Laboratory Improvement Amendments officers, and law librarians. Laws relating to the study objective were analyzed. 34 jurisdictions do not restrict the release of laboratory test results, while 17 states have laws that restrict to whom clinical laboratories can send copies of test results. In these states, pharmacists will have to use alternative sources, such as physician offices, to obtain test results. Pharmacists must consider state law before requesting copies of laboratory test results from clinical laboratories. This may be an issue that state pharmacy associations can address to increase pharmacist access to important patient information.

  17. A comparison of quality of present-day heat flow obtained from BHTs, Horner Plots of Malay Basin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Waples, D.W.; Mahadir, R.

    1994-07-01

    Reconciling temperature data obtained from measurement of single BHT, multiple BHT at a single depth, RFTs, and DSTs, is very difficult. Quality of data varied widely, however DST data were assumed to be most reliable. Data from 87 wells was used in this study, but only 47 wells have DST data. BASINMOD program was used to calculate the present-day heat flow, using measured thermal conductivity and calibrated against the DST data. The heat flows obtained from the DST data were assumed to be correct and representative throughout the basin. Then, heat flows using (1) uncorrected RFT data, (2) multiple BHTmore » data corrected by the Horner plot method, and (3) single BHT values corrected upward by a standard 10% were calculated. All of these three heat-flow populations had identically standard deviations to that for the DST data, but with significantly lower mean values. Correction factors were calculated to give each of the three erroneous populations the same mean value as the DST population. Heat flows calculated from RFT data had to be corrected upward by a factor of 1.12 to be equivalent to DST data; Horner plot data corrected by a factor of 1.18, and single BHT data by a factor of 1.2. These results suggest that present-day subsurface temperatures using RFT, Horner plot, and BHT data are considerably lower than they should be. The authors suspect qualitatively similar results would be found in other areas. Hence, they recommend significant corrections be routinely made until local calibration factors are established.« less

  18. Availability and quality of illegitimate somatropin products obtained from the Internet.

    PubMed

    Vida, Róbert György; Fittler, András; Mikulka, Ivett; Ábrahám, Eszter; Sándor, Viktor; Kilár, Ferenc; Botz, Lajos

    2017-02-01

    Background Growth hormones are widely available on the Internet for those who want to enhance their physical performance and improve body satisfaction. Illegitimate websites market somatropin injections without medical prescription and encourage misuse. Customers potentially put their health at risk when purchasing parenteral medications online. Objective The objective of our study was to evaluate the online market of no-prescription somatropin products and to analyse and document Internet pharmacy characteristics, distribution and pharmaceutical quality. Setting Websites indexed in Google promoting somatropin for sale direct to patients. Method Websites promoting the sale of growth hormone products were identified and analysed from June to August 2014. Internet vendor sites were evaluated to identify possible patient and medication safety concerns. Website characteristics, delivery time, storage conditions, packaging and attached product information were assessed. Investigation of the somatropin content was achieved using capillary electrophoresis with UV detection and electrospray ionization mass spectrometry. Main outcome measure Accessibility and quality of somatropin injections. Results Seventeen individual Internet vendor websites distributed somatropin products directly to patients, majority (94%) did not require a valid medical prescription before dispensing the products. Majority (70%) of Internet pharmacies displayed no medical information and none (0%) of the vendors displayed any regulatory body logo. All online samples had significantly (p < 0.001) lower somatropin concentration than labelled. Conclusion Our results clearly illustrate that prescription only biologic drugs are widely available online and can be easily accessed by anyone. Unprofessional distribution and handling is likely to cause degradation and possible patient safety concerns.

  19. Quality and Trace Element Profile of Tunisian Olive Oils Obtained from Plants Irrigated with Treated Wastewater

    PubMed Central

    Benincasa, Cinzia; Gharsallaoui, Mariem; Perri, Enzo; Briccoli Bati, Caterina; Ayadi, Mohamed; Khlif, Moncen; Gabsi, Slimane

    2012-01-01

    In the present work the use of treated wastewater (TWW) to irrigate olive plants was monitored. This type of water is characterized by high salinity and retains a substantial amount of trace elements, organic and metallic compounds that can be transferred into the soil and into the plants and fruits. In order to evaluate the impact of TWW on the overall quality of the oils, the time of contact of the olives with the soil has been taken into account. Multi-element data were obtained using ICP-MS. Nineteen elements (Li, B, Na, Mg, Al, K, Ca, Sc, Cr, Mn, Fe, Co, Ni, Cu, Zn, Sr, Mo, Ba and La) were submitted for statistical analysis. Using analysis of variance, linear discriminant analysis and principal component analysis it was possible to differentiate between oils produced from different batches of olives whose plants received different types of water. Also, the results showed that there was correlation between the elemental and mineral composition of the water used to irrigate the olive plots and the elemental and mineral composition of the oils. PMID:22654625

  20. Bioactive compounds and quality parameters of avocado oil obtained by different processes.

    PubMed

    Krumreich, Fernanda D; Borges, Caroline D; Mendonça, Carla Rosane B; Jansen-Alves, Cristina; Zambiazi, Rui C

    2018-08-15

    The objective of this study was to evaluate the quality of avocado oil whose pulp was processed through different drying and oil extraction methods. The physicochemical characteristics of avocados cv. Breda were determined after drying the pulp in an oven under ventilation (40 °C and 60 °C) and vacuum oven (60 °C), followed by the oil extracted by mechanical pressing or the Soxhlet method. From the approximately 72% pulp found in the avocado fruit, the 16% fraction is lipids. The quality indices evaluated in avocado oil showed better results when the pulp was dried at 60 °C under vacuum and oil extraction was done by the Soxhlet method with petroleum ether, whereas the bioactive compounds were better preserved when the avocado pulp was dried at 60 °C under ventilation and mechanical pressing was used for the oil extraction. Among the fatty acids found, oleic acid was the main. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Better Data Quality for Better Healthcare Research Results - A Case Study.

    PubMed

    Hart, Robert; Kuo, Mu-Hsing

    2017-01-01

    Electronic Health Records (EHRs) have been identified as a key tool to collect data for healthcare research. However, EHR data must be of sufficient quality to support quality research results. Island Health, BC, Canada has invested and continues to invest in the development of solutions to address the quality of its EHR data and support high quality healthcare studies. This paper examines Island Health's data quality engine, its development and its successful implementation.

  2. Simbol-X Hard X-ray Focusing Mirrors: Results Obtained During the Phase A Study

    NASA Astrophysics Data System (ADS)

    Tagliaferri, G.; Basso, S.; Borghi, G.; Burkert, W.; Citterio, O.; Civitani, M.; Conconi, P.; Cotroneo, V.; Freyberg, M.; Garoli, D.; Gorenstein, P.; Hartner, G.; Mattarello, V.; Orlandi, A.; Pareschi, G.; Romaine, S.; Spiga, D.; Valsecchi, G.; Vernani, D.

    2009-05-01

    Simbol-X will push grazing incidence imaging up to 80 keV, providing a strong improvement both in sensitivity and angular resolution compared to all instruments that have operated so far above 10 keV. The superb hard X-ray imaging capability will be guaranteed by a mirror module of 100 electroformed Nickel shells with a multilayer reflecting coating. Here we will describe the technogical development and solutions adopted for the fabrication of the mirror module, that must guarantee an Half Energy Width (HEW) better than 20 arcsec from 0.5 up to 30 keV and a goal of 40 arcsec at 60 keV. During the phase A, terminated at the end of 2008, we have developed three engineering models with two, two and three shells, respectively. The most critical aspects in the development of the Simbol-X mirrors are i) the production of the 100 mandrels with very good surface quality within the timeline of the mission, ii) the replication of shells that must be very thin (a factor of 2 thinner than those of XMM-Newton) and still have very good image quality up to 80 keV, iii) the development of an integration process that allows us to integrate these very thin mirrors maintaining their intrinsic good image quality. The Phase A study has shown that we can fabricate the mandrels with the needed quality and that we have developed a valid integration process. The shells that we have produced so far have a quite good image quality, e.g. HEW <~30 arcsec at 30 keV, and effective area. However, we still need to make some improvements to reach the requirements. We will briefly present these results and discuss the possible improvements that we will investigate during phase B.

  3. Results obtained with a low cost software-based audiometer for hearing screening.

    PubMed

    Ferrari, Deborah Viviane; Lopez, Esteban Alejandro; Lopes, Andrea Cintra; Aiello, Camila Piccini; Jokura, Pricila Reis

    2013-07-01

     The implementation of hearing screening programs can be facilitated by reducing operating costs, including the cost of equipment. The Telessaúde (TS) audiometer is a low-cost, software-based, and easy-to-use piece of equipment for conducting audiometric screening.  To evaluate the TS audiometer for conducting audiometric screening.  A prospective randomized study was performed. Sixty subjects, divided into those who did not have (group A, n = 30) and those who had otologic complaints (group B, n = 30), underwent audiometric screening with conventional and TS audiometers in a randomized order. Pure tones at 25 dB HL were presented at frequencies of 500, 1000, 2000, and 4000 Hz. A "fail" result was considered when the individual failed to respond to at least one of the stimuli. Pure-tone audiometry was also performed on all participants. The concordance of the results of screening with both audiometers was evaluated. The sensitivity, specificity, and positive and negative predictive values of screening with the TS audiometer were calculated.  For group A, 100% of the ears tested passed the screening. For group B, "pass" results were obtained in 34.2% (TS) and 38.3% (conventional) of the ears tested. The agreement between procedures (TS vs. conventional) ranged from 93% to 98%. For group B, screening with the TS audiometer showed 95.5% sensitivity, 90.4% sensitivity, and positive and negative predictive values equal to 94.9% and 91.5%, respectively.  The results of the TS audiometer were similar to those obtained with the conventional audiometer, indicating that the TS audiometer can be used for audiometric screening.

  4. Ride qualities criteria validation/pilot performance study: Flight test results

    NASA Technical Reports Server (NTRS)

    Nardi, L. U.; Kawana, H. Y.; Greek, D. C.

    1979-01-01

    Pilot performance during a terrain following flight was studied for ride quality criteria validation. Data from manual and automatic terrain following operations conducted during low level penetrations were analyzed to determine the effect of ride qualities on crew performance. The conditions analyzed included varying levels of turbulence, terrain roughness, and mission duration with a ride smoothing system on and off. Limited validation of the B-1 ride quality criteria and some of the first order interactions between ride qualities and pilot/vehicle performance are highlighted. An earlier B-1 flight simulation program correlated well with the flight test results.

  5. Analysis of information quality attribute for SME towards adoption of research result

    NASA Astrophysics Data System (ADS)

    Febriani, E.; Dewobroto, W. S.; Anggraini, R. D.

    2017-12-01

    Small and Medium Enterprises (SME) holds significant role in fostering Indonesian economy. However, the research that is supposed to support the development of SMEs business has not yet fully adopted or utilized. Information attributes may be used as the benchmark to find the intention of SMEs from a research result and develop the strategy of quality information for all organizations both SMEs and the researcher. Therefore, because of the importance of information quality attribute required by SMEs, the research aims to analyses the information quality required by SMEs to clarify the information quality into the dimension of information quality. The research was started by distributing online questionnaire to SMEs. The questionnaire result showed that the content dimension is the most aspect required by SMEs, followed by time and form dimension, respectively. Quality information attribute required by SMEs from a research is that the result may be applied to the business.

  6. [Risk adjusted assessment of quality of perinatal centers - results of perinatal/neonatal quality surveillance in Saxonia].

    PubMed

    Koch, R; Gmyrek, D; Vogtmann, Ch

    2005-12-01

    The weak point of the country-wide perinatal/neonatal quality surveillance as a tool for evaluation of achievements of a distinct clinic, is the ignorance of interhospital differences in the case-mix of patients. Therefore, that approach can not result in a reliable bench marking. To adjust the results of quality assessment of different hospitals according to their risk profile of patients by multivariate analysis. The perinatal/neonatal data base of 12.783 newborns of the saxonian quality surveillance from 1998 to 2000 was analyzed. 4 relevant quality indicators of newborn outcome -- a) severe intraventricular hemorrhage in preterm infants < 1500 g, b) death in hospital of preterm infants < 1500 g, c) death in newborns with birth weight > 2500 g and d) hypoxic-ischemic encephalopathy -- were targeted to find out specific risk predictors by considering 26 risk factors. A logistic regression model was used to develop the risk predictors. Risk predictors for the 4 quality indicators could be described by 3 - 9 out of 26 analyzed risk factors. The AUC (ROC)-values for these quality indicators were 82, 89, 89 and 89 %, what signifies their reliability. Using the new specific predictors for calculation the risk adjusted incidence rates of quality indicator yielded in some remarkable changes. The apparent differences in the outcome criteria of analyzed hospitals were found to be much less pronounced. The application of the proposed method for risk adjustment of quality indicators makes it possible to perform a more objective comparison of neonatal outcome criteria between different hospitals or regions.

  7. Obtaining high resolution XUV coronal images

    NASA Technical Reports Server (NTRS)

    Golub, L.; Spiller, E.

    1992-01-01

    Photographs obtained during three flights of an 11 inch diameter normal incident soft X-ray (wavelength 63.5 A) telescope are analyzed and the data are compared to the results expected from tests of the mirror surfaces. Multilayer coated X ray telescopes have the potential for 0.01 arcsec resolution, and there is optimism that such high quality mirrors can be built. Some of the factors which enter into the performance actually achieved in practice are as follows: quality of the mirror substrate, quality of the multilayer coating, and number of photons collected. Measurements of multilayer mirrors show that the actual performance achieved in the solar X-ray images demonstrates a reduction in the scattering compared to that calculated from the topography of the top surface of the multilayer. In the brief duration of a rocket flight, the resolution is also limited by counting statistics from the number of photons collected. At X-ray Ultraviolet (XUV) wavelengths from 171 to 335 A the photon flux should be greater than 10(exp 10) ph/sec, so that a resolution better than 0.1 arcsec might be achieved, if mirror quality does not provide a limit first. In a satellite, a large collecting area will be needed for the highest resolution.

  8. Method for obtaining a collimated near-unity aspect ratio output beam from a DFB-GSE laser with good beam quality.

    PubMed

    Liew, S K; Carlson, N W

    1992-05-20

    A simple method for obtaining a collimated near-unity aspect ratio output beam from laser sources with extremely large (> 100:1) aspect ratios is demonstrated by using a distributed-feedback grating-surfaceemitting laser. Far-field power-in-the-bucket measurements of the laser indicate good beam quality with a high Strehl ratio.

  9. A quality score for coronary artery tree extraction results

    NASA Astrophysics Data System (ADS)

    Cao, Qing; Broersen, Alexander; Kitslaar, Pieter H.; Lelieveldt, Boudewijn P. F.; Dijkstra, Jouke

    2018-02-01

    Coronary artery trees (CATs) are often extracted to aid the fully automatic analysis of coronary artery disease on coronary computed tomography angiography (CCTA) images. Automatically extracted CATs often miss some arteries or include wrong extractions which require manual corrections before performing successive steps. For analyzing a large number of datasets, a manual quality check of the extraction results is time-consuming. This paper presents a method to automatically calculate quality scores for extracted CATs in terms of clinical significance of the extracted arteries and the completeness of the extracted CAT. Both right dominant (RD) and left dominant (LD) anatomical statistical models are generated and exploited in developing the quality score. To automatically determine which model should be used, a dominance type detection method is also designed. Experiments are performed on the automatically extracted and manually refined CATs from 42 datasets to evaluate the proposed quality score. In 39 (92.9%) cases, the proposed method is able to measure the quality of the manually refined CATs with higher scores than the automatically extracted CATs. In a 100-point scale system, the average scores for automatically and manually refined CATs are 82.0 (+/-15.8) and 88.9 (+/-5.4) respectively. The proposed quality score will assist the automatic processing of the CAT extractions for large cohorts which contain both RD and LD cases. To the best of our knowledge, this is the first time that a general quality score for an extracted CAT is presented.

  10. Analysis of results obtained using the automatic chemical control of the quality of the water heat carrier in the drum boiler of the Ivanovo CHP-3 power plant

    NASA Astrophysics Data System (ADS)

    Larin, A. B.; Kolegov, A. V.

    2012-10-01

    Results of industrial tests of the new method used for the automatic chemical control of the quality of boiler water of the drum-type power boiler ( P d = 13.8 MPa) are described. The possibility of using an H-cationite column for measuring the electric conductivity of an H-cationized sample of boiler water over a long period of time is shown.

  11. 40 CFR 1515.10 - Obtaining available information.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Obtaining available information. 1515.10 Section 1515.10 Protection of Environment COUNCIL ON ENVIRONMENTAL QUALITY FREEDOM OF INFORMATION ACT PROCEDURES Availability of Information § 1515.10 Obtaining available information. (a) When a...

  12. Quality index of radiological devices: results of one year of use.

    PubMed

    Tofani, Alessandro; Imbordino, Patrizia; Lecci, Antonio; Bonannini, Claudia; Del Corona, Alberto; Pizzi, Stefano

    2003-01-01

    The physical quality index (QI) of radiological devices summarises in a single numerical value between 0 and 1 the results of constancy tests. The aim of this paper is to illustrate the results of the use of such an index on all public radiological devices in the Livorno province over one year. The quality index was calculated for 82 radiological devices of a wide range of types by implementing its algorithm in a spreadsheet-based software for the automatic handling of quality control data. The distribution of quality index values was computed together with the associated statistical quantities. This distribution is strongly asymmetrical, with a sharp peak near the highest QI values. The mean quality index values for the different types of device show some inhomogeneity: in particular, mammography and panoramic dental radiography devices show far lower quality than other devices. In addition, our analysis has identified the parameters that most frequently do not pass the quality tests for each type of device. Finally, we sought some correlation between quality and age of the device, but this was poorly significant. The quality index proved to be a useful tool providing an overview of the physical conditions of radiological devices. By selecting adequate QI threshold values for, it also helps to decide whether a given device should be upgraded or replaced. The identification of critical parameters for each type of device may be used to improve the definition of the QI by attributing greater weights to critical parameters, so as to better address the maintenance of radiological devices.

  13. Sentinel-2 radiometric image quality commissioning: first results

    NASA Astrophysics Data System (ADS)

    Lachérade, S.; Lonjou, V.; Farges, M.; Gamet, P.; Marcq, S.; Raynaud, J.-L.; Trémas, T.

    2015-10-01

    In partnership with the European Commission and in the frame of the Copernicus program, the European Space Agency (ESA) is developing the Sentinel-2 optical imaging mission devoted to the operational monitoring of land and coastal areas. The Sentinel-2 mission is based on a satellites constellation deployed in polar sun-synchronous orbit. Sentinel-2 offers a unique combination of global coverage with a wide field of view (290km), a high revisit (5 days with two satellites), a high spatial resolution (10m, 20m and 60m) and multi-spectral imagery (13 spectral bands in visible and shortwave infrared domains). The first satellite, Sentinel-2A, has been launched in June 2015. The Sentinel-2A Commissioning Phase starts immediately after the Launch and Early Orbit Phase and continues until the In-Orbit Commissioning Review which is planned three months after the launch. The Centre National d'Etudes Spatiales (CNES) supports ESA/ESTEC to insure the Calibration/Validation commissioning phase during the first three months in flight. This paper provides first an overview of the Sentinel-2 system and a description of the products delivered by the ground segment associated to the main radiometric specifications to achieve. Then the paper focuses on the preliminary radiometric results obtained during the in-flight commissioning phase. The radiometric methods and calibration sites used in the CNES image quality center to reach the specifications of the sensor are described. A status of the Sentinel-2A radiometric performances at the end of the first three months after the launch is presented. We will particularly address in this paper the results in term of absolute calibration, pixel to pixel relative sensitivity and MTF estimation.

  14. Application of Oversampling to obtain the MTF of Digital Radiology Equipment.

    NASA Astrophysics Data System (ADS)

    Narváez, M.; Graffigna, J. P.; Gómez, M. E.; Romo, R.

    2016-04-01

    Within the objectives of theproject Medical Image Processing for QualityAssessment ofX Ray Imaging, the present research work is aimed at developinga phantomX ray image and itsassociated processing algorithms in order to evaluatethe image quality rendered by digital X ray equipment. These tools are used to measure various image parameters, among which spatial resolution shows afundamental property that can be characterized by the Modulation Transfer Function (MTF)of an imaging system [1]. After performing a thorough literature surveyon imaging quality control in digital X film in Argentine and international publications, it was decided to adopt for this work the Norm IEC 62220 1:2003 that recommends using an image edge as a testingmethod. In order to obtain the characterizing MTF, a protocol was designedfor unifying the conditions under which the images are acquired for later evaluation. The protocol implied acquiring a radiography image by means of a specific referential technique, i.e. referred either to voltage, current, time, distance focus plate (/film?) distance, or other referential parameter, and to interpret the image through a system of computed radiology or direct digital radiology. The contribution of the work stems from the fact that, even though the traditional way of evaluating an X film image quality has relied mostly on subjective methods, this work presents an objective evaluative toolfor the images obtained with a givenequipment, followed by a contrastive analysis with the renderings from other X filmimaging sets.Once the images were obtained, specific calculations were carried out. Though there exist some methods based on the subjective evaluation of the quality of image, this work offers an objective evaluation of the equipment under study. Finally, we present the results obtained on different equipment.

  15. Results of the 2013 UT modeling benchmark obtained with models implemented in CIVA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Toullelan, Gwénaël; Raillon, Raphaële; Chatillon, Sylvain

    The 2013 Ultrasonic Testing (UT) modeling benchmark concerns direct echoes from side drilled holes (SDH), flat bottom holes (FBH) and corner echoes from backwall breaking artificial notches inspected with a matrix phased array probe. This communication presents the results obtained with the models implemented in the CIVA software: the pencilmodel is used to compute the field radiated by the probe, the Kirchhoff approximation is applied to predict the response of FBH and notches and the SOV (Separation Of Variables) model is used for the SDH responses. The comparison between simulated and experimental results are presented and discussed.

  16. Comparison of results obtained with various sensors used to measure fluctuating quantities in jets.

    NASA Technical Reports Server (NTRS)

    Parthasarathy, S. P.; Massier, P. F.; Cuffel, R. F.

    1973-01-01

    An experimental investigation has been conducted to compare the results obtained with six different instruments that sense fluctuating quantities in free jets. These sensors are typical of those that have recently been used by various investigators who are engaged in experimental studies of jet noise. Intensity distributions and two-point correlations with space separation and time delay were obtained. The static pressure, density, and velocity fluctuations are well correlated over the entire cross section of the jet and the cross-correlations persist for several jet diameters along the flow direction. The eddies appear to be flattened in the flow direction by a ratio of 0.4.

  17. The relevance of external quality assessment for molecular testing for ALK positive non-small cell lung cancer: results from two pilot rounds show room for optimization.

    PubMed

    Tembuyser, Lien; Tack, Véronique; Zwaenepoel, Karen; Pauwels, Patrick; Miller, Keith; Bubendorf, Lukas; Kerr, Keith; Schuuring, Ed; Thunnissen, Erik; Dequeker, Elisabeth M C

    2014-01-01

    Molecular profiling should be performed on all advanced non-small cell lung cancer with non-squamous histology to allow treatment selection. Currently, this should include EGFR mutation testing and testing for ALK rearrangements. ROS1 is another emerging target. ALK rearrangement status is a critical biomarker to predict response to tyrosine kinase inhibitors such as crizotinib. To promote high quality testing in non-small cell lung cancer, the European Society of Pathology has introduced an external quality assessment scheme. This article summarizes the results of the first two pilot rounds organized in 2012-2013. Tissue microarray slides consisting of cell-lines and resection specimens were distributed with the request for routine ALK testing using IHC or FISH. Participation in ALK FISH testing included the interpretation of four digital FISH images. Data from 173 different laboratories was obtained. Results demonstrate decreased error rates in the second round for both ALK FISH and ALK IHC, although the error rates were still high and the need for external quality assessment in laboratories performing ALK testing is evident. Error rates obtained by FISH were lower than by IHC. The lowest error rates were observed for the interpretation of digital FISH images. There was a large variety in FISH enumeration practices. Based on the results from this study, recommendations for the methodology, analysis, interpretation and result reporting were issued. External quality assessment is a crucial element to improve the quality of molecular testing.

  18. Characterisation of Aronia powders obtained by different drying processes.

    PubMed

    Horszwald, Anna; Julien, Heritier; Andlauer, Wilfried

    2013-12-01

    Nowadays, food industry is facing challenges connected with the preservation of the highest possible quality of fruit products obtained after processing. Attention has been drawn to Aronia fruits due to numerous health promoting properties of their products. However, processing of Aronia, like other berries, leads to difficulties that stem from the preparation process, as well as changes in the composition of bioactive compounds. Consequently, in this study, Aronia commercial juice was subjected to different drying techniques: spray drying, freeze drying and vacuum drying with the temperature range of 40-80 °C. All powders obtained had a high content of total polyphenols. Powders gained by spray drying had the highest values which corresponded to a high content of total flavonoids, total monomeric anthocyanins, cyaniding-3-glucoside and total proanthocyanidins. Analysis of the results exhibited a correlation between selected bioactive compounds and their antioxidant capacity. In conclusion, drying techniques have an impact on selected quality parameters, and different drying techniques cause changes in the content of bioactives analysed. Spray drying can be recommended for preservation of bioactives in Aronia products. Powder quality depends mainly on the process applied and parameters chosen. Therefore, Aronia powders production should be adapted to the requirements and design of the final product. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Using Riemannian geometry to obtain new results on Dikin and Karmarkar methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oliveira, P.; Joao, X.; Piaui, T.

    1994-12-31

    We are motivated by a 1990 Karmarkar paper on Riemannian geometry and Interior Point Methods. In this talk we show 3 results. (1) Karmarkar direction can be derived from the Dikin one. This is obtained by constructing a certain Z(x) representation of the null space of the unitary simplex (e, x) = 1; then the projective direction is the image under Z(x) of the affine-scaling one, when it is restricted to that simplex. (2) Second order information on Dikin and Karmarkar methods. We establish computable Hessians for each of the metrics corresponding to both directions, thus permitting the generation ofmore » {open_quotes}second order{close_quotes} methods. (3) Dikin and Karmarkar geodesic descent methods. For those directions, we make computable the theoretical Luenberger geodesic descent method, since we are able to explicit very accurate expressions of the corresponding geodesics. Convergence results are given.« less

  20. The Relevance of External Quality Assessment for Molecular Testing for ALK Positive Non-Small Cell Lung Cancer: Results from Two Pilot Rounds Show Room for Optimization

    PubMed Central

    Tembuyser, Lien; Tack, Véronique; Zwaenepoel, Karen; Pauwels, Patrick; Miller, Keith; Bubendorf, Lukas; Kerr, Keith; Schuuring, Ed; Thunnissen, Erik; Dequeker, Elisabeth M. C.

    2014-01-01

    Background and Purpose Molecular profiling should be performed on all advanced non-small cell lung cancer with non-squamous histology to allow treatment selection. Currently, this should include EGFR mutation testing and testing for ALK rearrangements. ROS1 is another emerging target. ALK rearrangement status is a critical biomarker to predict response to tyrosine kinase inhibitors such as crizotinib. To promote high quality testing in non-small cell lung cancer, the European Society of Pathology has introduced an external quality assessment scheme. This article summarizes the results of the first two pilot rounds organized in 2012–2013. Materials and Methods Tissue microarray slides consisting of cell-lines and resection specimens were distributed with the request for routine ALK testing using IHC or FISH. Participation in ALK FISH testing included the interpretation of four digital FISH images. Results Data from 173 different laboratories was obtained. Results demonstrate decreased error rates in the second round for both ALK FISH and ALK IHC, although the error rates were still high and the need for external quality assessment in laboratories performing ALK testing is evident. Error rates obtained by FISH were lower than by IHC. The lowest error rates were observed for the interpretation of digital FISH images. Conclusion There was a large variety in FISH enumeration practices. Based on the results from this study, recommendations for the methodology, analysis, interpretation and result reporting were issued. External quality assessment is a crucial element to improve the quality of molecular testing. PMID:25386659

  1. Near-Infrared Scintillation of Liquid Argon: Recent Results Obtained with the NIR Facility at Fermilab

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Escobar, C. O.; Rubinov, P.; Tilly, E.

    After a short review of previous attempts to observe and measure the near-infrared scintillation in liquid argon, we present new results obtained with NIR, a dedicated cryostat at the Fermilab Proton Assembly Building (PAB). The new results give confidence that the near-infrared light can be used as the much needed light signal in large liquid argon time projection chambers.11 pages,

  2. [Analysis of the results of the 2010 External Quality Control Program of the Spanish Society of Infectious Diseases and Clinical Microbiology for HIV-1, HCV, and HBV viral loads].

    PubMed

    Orta Mira, Nieves; Serrano, María del Remedio Guna; Martínez, José-Carlos Latorre; Ovies, María Rosario; Poveda, Marta; de Gopegui, Enrique Ruiz; Cardona, Concepción Gimeno

    2011-12-01

    Human immunodeficiency virus type 1 (HIV-1) and hepatitis B (HBV) and C virus (HCV) viral load determinations are among the most important markers for the follow-up of patients infected with these viruses. External quality control tools are crucial to ensure the accuracy of the results obtained by microbiology laboratories. This article summarized the results obtained in the 2010 External Quality Control Program of the Spanish Society of Infectious Diseases and Clinical Microbiology for HIV-1, HCV, and HBV viral loads and HCV genotyping. In the HIV-1 program, a total of five standards were sent. One standard consisted of seronegative human plasma, while the remaining four contained plasma from three different viremic patients, in the range of 3-5 log(10) copies/mL; two of these standards were identical, with the aim of determining repeatability. A significant proportion of the laboratories (22.6% on average) obtained values out of the accepted range (mean ± 0.2 log(10)copies/mL), depending on the standard and on the method used for quantification. Repeatability was very good, with up to 95% of laboratories reporting results within the limits (Δ<0.5 log(10)copies/mL). The HBV and HCV program consisted of two standards with different viral load contents. Most of the participants, 86.1% in the case of HCV and 87.1% in HBV, obtained all the results within the accepted range (mean ± 1.96 SD log(10)UI/mL). Post-analytical errors due to mistranscription of the results were detected in these controls. Data from this analysis reinforce the utility of proficiency programs to ensure the quality of the results obtained by a particular laboratory, as well as the importance of the post-analytical phase in overall quality. Due to interlaboratory variability, use of the same method and the same laboratory for patient follow-up is advisable. Copyright © 2011 Elsevier España S.L. All rights reserved.

  3. How to obtain traceability on optical radiation measurements?

    NASA Astrophysics Data System (ADS)

    Matamoros García, Carlos H.

    2006-02-01

    Traceability to national standards provides confidence in measurements results, granting a guaranty when carrying out governmental rules and when demonstrating conformity with quality requirements such as ISO 9000 or ISO/IEC 17025 (and the Mexican equivalent standards). The appropriate traceability contributes with confidence of the quality of products or services. This paper presents different ways to obtain traceability in Mexico for the optical radiation measurements, mentioning some applications, and highlighting the necessity of having traceability to the appropriate units of the SI. Additionally it present the national standards maintained by Centro Nacional de Metrologia (CENAM), the national metrology institute in Mexico, that give the technical support to Mexican measurements in this field and the international recognition that the personal of the Optics and Radiometry Division had gained in 10 years of development.

  4. Gaining customer knowledge: obtaining and using customer judgments for hospitalwide quality improvement.

    PubMed

    Nelson, E C; Caldwell, C; Quinn, D; Rose, R

    1991-03-01

    Customer knowledge is an essential feature of hospitalwide quality improvement. All systems and processes have customers. The aim is to use customer knowledge and voice of the customer measurement to plan, design, improve, and monitor these systems and processes continuously. In this way, the hospital stands the best chance of meeting customers' needs and, hopefully, delivering services that are so outstanding that customers will be surprised and delighted. There are many methods, both soft and hard, that can be used to increase customer knowledge. One useful strategy is to use a family of quality measures that reflect the voice of the customer. These measures can generate practical and powerful customer knowledge information that is essential to performing strategic planning, deploying quality policy, designing new services, finding targets for improvements, and monitoring those continuous improvements based on customers' judgments.

  5. Legionella in water samples: how can you interpret the results obtained by quantitative PCR?

    PubMed

    Ditommaso, Savina; Ricciardi, Elisa; Giacomuzzi, Monica; Arauco Rivera, Susan R; Zotti, Carla M

    2015-02-01

    Evaluation of the potential risk associated with Legionella has traditionally been determined from culture-based methods. Quantitative polymerase chain reaction (qPCR) is an alternative tool that offers rapid, sensitive and specific detection of Legionella in environmental water samples. In this study we compare the results obtained by conventional qPCR (iQ-Check™ Quanti Legionella spp.; Bio-Rad) and by culture method on artificial samples prepared in Page's saline by addiction of Legionella pneumophila serogroup 1 (ATCC 33152) and we analyse the selective quantification of viable Legionella cells by the qPCR-PMA method. The amount of Legionella DNA (GU) determined by qPCR was 28-fold higher than the load detected by culture (CFU). Applying the qPCR combined with PMA treatment we obtained a reduction of 98.5% of the qPCR signal from dead cells. We observed a dissimilarity in the ability of PMA to suppress the PCR signal in samples with different amounts of bacteria: the effective elimination of detection signals by PMA depended on the concentration of GU and increasing amounts of cells resulted in higher values of reduction. Using the results from this study we created an algorithm to facilitate the interpretation of viable cell level estimation with qPCR-PMA. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Evaluation of Adherence to Quality Measures for Prostate Cancer Radiotherapy in the United States: Results from the Quality Research in Radiation Oncology (QRRO) Survey

    PubMed Central

    Zelefsky, Michael J.; Lee, W. Robert; Zietman, Anthony; Khalid, Najma; Crozier, Cheryl; Owen, Jean; Wilson, J. Frank

    2012-01-01

    Purpose To test the feasibility of using proposed quality indicators to assess radiotherapy quality in prostate cancer management based on a 2007 stratified random survey of treating academic and non-academic US institutions. Methods and Materials 414 patients with clinically localized prostate cancer treated with external beam radiotherapy (EBRT) or brachytherapy were selected from 45 institutions. Indicators used as specific measurable clinical performance measures to represent surrogates for quality of radiotherapy delivery included established measures, such as the use of prescription doses ≥75 Gy for intermediate- and high-risk EBRT patients and androgen-deprivation therapy (ADT) in conjunction with EBRT for patients with high-risk disease, and emerging measures, including daily target localization (image-guidance) to correct for organ motion for EBRT patients. Results 167 patients (47%) were treated with 6 MV photons, 31 (9%) were treated with 10 MV, 65 (18%) received 15 MV, and the remaining 90 (26%) 16–23 MV. For intermediate- plus high-risk patients (n=181), 78% were treated to ≥75 Gy. Among favorable-risk patients, 72% were treated to ≥75 Gy. Among high-risk EBRT patients, 60 (87%) were treated with ADT in conjunction with EBRT and 13% (n=9) with radiotherapy alone. Among low- and intermediate-risk patients, 10% and 42%, respectively, were treated with ADT plus EBRT. For 24% of EBRT patients (85/354), weekly electronic portal imaging was obtained as verification films without daily target localization and the remaining 76% were treated with daily localization of the target using various methods. Conclusions Adherence to defined quality indicators was observed in a majority of patients. ≈90% of high-risk patients are treated with ADT plus EBRT and ≈80% of intermediate- and high-risk patients receive prescription doses >=75 Gy, consistent with the published results of randomized trials. PMID:23471563

  7. Modeling Quality-Adjusted Life Expectancy Loss Resulting from Tobacco Use in the United States

    ERIC Educational Resources Information Center

    Kaplan, Robert M.; Anderson, John P.; Kaplan, Cameron M.

    2007-01-01

    Purpose: To describe the development of a model for estimating the effects of tobacco use upon Quality Adjusted Life Years (QALYs) and to estimate the impact of tobacco use on health outcomes for the United States (US) population using the model. Method: We obtained estimates of tobacco consumption from 6 years of the National Health Interview…

  8. Effects of manganese on routine semen quality parameters: results from a population-based study in China

    PubMed Central

    2012-01-01

    Background Manganese (Mn) is an essential element in humans but its effect on semen quality is unclear. This study therefore aimed to assess the effects of Mn on semen quality in healthy men with no occupational exposure to Mn. Methods Semen samples were obtained from healthy Chinese men 20–59 years old who were recruited from six provinces in China. Individuals with urogenital tract diseases, tuberculosis, or occupational exposure to heavy metals were excluded. A questionnaire survey was conducted, and the external genitalia, semen quality, and serum Mn levels were examined. Results A total of 1,179 volunteers were enrolled in this study. The median serum Mn concentration was 8.2 μg/L (25th percentile (P25)=3.7 μg/L, P75=16.2μg/L). After adjusted area (six provinces), abstinence interval, season, registered residence, age of subjects, education level, income, smoking, and drinking, the risk of teratospermia was increased at serum Mn concentrations >19.40 μg/L (P80) group, with an adjusted odds ratio of 2.27 (95% confidence interval: 1.18–4.37). Conclusion High serum Mn levels appeared to have harmful effects on sperm morphology and motility among healthy men with no occupational exposure to Mn. PMID:23107312

  9. Quality of work, well-being, and intended early retirement of older employees: baseline results from the SHARE Study.

    PubMed

    Siegrist, Johannes; Wahrendorf, Morten; von dem Knesebeck, Olaf; Jürges, Hendrik; Börsch-Supan, Axel

    2007-02-01

    Given the challenge of a high proportion of older employees who retire early from work we analyse associations of indicators of a poor psychosocial quality of work with intended premature departure from work in a large sample of older male and female employees in 10 European countries. Baseline data from the 'Survey of Health, Ageing and Retirement in Europe' (SHARE) were obtained from 3523 men and 3318 women in 10 European countries. Data on intended early retirement, four measures of well-being (self-rated health, depressive symptoms, general symptom load, and quality of life), and quality of work (effort-reward imbalance; low control at work) were obtained from structured interviews and questionnaires. Country-specific and total samples are analysed, using logistic regression analysis. Poor quality of work is significantly associated with intended early retirement. After adjustment for well-being odds ratios (OR) of effort-reward imbalance [OR 1.72 (1.43-2.08)] and low control at work [OR 1.51 (1.27-1.80)] on intended early retirement are observed. Poor quality of work and reduced well-being are independently associated with the intention to retire from work. The consistent association of a poor psychosocial quality of work with intended early retirement among older employees across all European countries under study calls for improved investments into better quality of work, in particular increased control and an appropriate balance between efforts spent and rewards received at work.

  10. An assessment of consistence of exhaust gas emission test results obtained under controlled NEDC conditions

    NASA Astrophysics Data System (ADS)

    Balawender, K.; Jaworski, A.; Kuszewski, H.; Lejda, K.; Ustrzycki, A.

    2016-09-01

    Measurements concerning emissions of pollutants contained in automobile combustion engine exhaust gases is of primary importance in view of their harmful impact on the natural environment. This paper presents results of tests aimed at determining exhaust gas pollutant emissions from a passenger car engine obtained under repeatable conditions on a chassis dynamometer. The test set-up was installed in a controlled climate chamber allowing to maintain the temperature conditions within the range from -20°C to +30°C. The analysis covered emissions of such components as CO, CO2, NOx, CH4, THC, and NMHC. The purpose of the study was to assess repeatability of results obtained in a number of tests performed as per NEDC test plan. The study is an introductory stage of a wider research project concerning the effect of climate conditions and fuel type on emission of pollutants contained in exhaust gases generated by automotive vehicles.

  11. Processing multispectral data obtained by orbital platforms of the LANDSAT series for studies of water quality in Guanabara Bay. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Dejesusparada, N. (Principal Investigator); Verdesio, J. J.

    1981-01-01

    The relationship existing between Guanabara Bay water quality ground truth parameters and LANDSAT MSS video data was investigated. The parameters considered were: chorophyll content, water transparency usng the Secchi disk, salinity, and dissolved ammonia. Data from two overflights was used, and methods of processing digital data were compared. Linear and nonlinear regression analyses were utilized, comparing original data with processed data by using the correlation coefficient and the estimation mean error. It was determined that better quality data are obtained by using radiometric correction programs with a physical basis, contrast ratio, and normalization. Incidental locations of floating vegetation, changes in bottom depth, oil slicks, and ships at anchor were made.

  12. Microbiological quality of fresh produce obtained from retail stores on the Eastern Shore of Maryland, United States of America.

    PubMed

    Korir, Robert Cheruiyot; Parveen, Salina; Hashem, Fawzy; Bowers, John

    2016-06-01

    The aim of this study was to investigate the microbiological quality of six types of fresh produce obtained from three retail stores located on the Eastern Shore of Maryland, USA. A total of 414 samples representing basil, cilantro, lettuce, scallion, spinach, and parsley were analyzed for total aerobic bacteria (APC), total coliforms, Escherichia coli, and three pathogenic bacteria (E. coli O157:H7, Listeria monocytogenes, and Salmonella), using standard methods. Presumptive pathogenic isolates were confirmed using BAX Polymerase Chain Reaction. Total aerobic populations varied widely between samples, while 38.41% were positive for total coliforms and only 10.15% for E. coli. Median abundance (log CFU/g) of total coliforms and E. coli were less than the limit of detection and that of APC ranged from 5.78 to 6.61 over the six produce types. There was a statistically significant difference in prevalence of total coliforms among the retail stores, but not for abundance of APC or prevalence of E. coli. E. coli O157:H7 and L. monocytogenes were detected in one spinach sample each, while one parsley and one cilantro sample were positive for Salmonella. There were no statistically significant differences in microbiological quality among produce types. Although the results of this study provided some indices of sanitary and/or spoilage level, no relationship was observed among the total aerobic bacteria, total coliforms, E. coli, and the presence of pathogenic bacteria in the samples tested. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Glucose Meters: A Review of Technical Challenges to Obtaining Accurate Results

    PubMed Central

    Tonyushkina, Ksenia; Nichols, James H.

    2009-01-01

    , anemia, hypotension, and other disease states. This article reviews the challenges involved in obtaining accurate glucose meter results. PMID:20144348

  14. Influence of raw milk quality on processed dairy products: How do raw milk quality test results relate to product quality and yield?

    PubMed

    Murphy, Steven C; Martin, Nicole H; Barbano, David M; Wiedmann, Martin

    2016-12-01

    This article provides an overview of the influence of raw milk quality on the quality of processed dairy products and offers a perspective on the merits of investing in quality. Dairy farmers are frequently offered monetary premium incentives to provide high-quality milk to processors. These incentives are most often based on raw milk somatic cell and bacteria count levels well below the regulatory public health-based limits. Justification for these incentive payments can be based on improved processed product quality and manufacturing efficiencies that provide the processor with a return on their investment for high-quality raw milk. In some cases, this return on investment is difficult to measure. Raw milks with high levels of somatic cells and bacteria are associated with increased enzyme activity that can result in product defects. Use of raw milk with somatic cell counts >100,000cells/mL has been shown to reduce cheese yields, and higher levels, generally >400,000 cells/mL, have been associated with textural and flavor defects in cheese and other products. Although most research indicates that fairly high total bacteria counts (>1,000,000 cfu/mL) in raw milk are needed to cause defects in most processed dairy products, receiving high-quality milk from the farm allows some flexibility for handling raw milk, which can increase efficiencies and reduce the risk of raw milk reaching bacterial levels of concern. Monitoring total bacterial numbers in regard to raw milk quality is imperative, but determining levels of specific types of bacteria present has gained increasing importance. For example, spores of certain spore-forming bacteria present in raw milk at very low levels (e.g., <1/mL) can survive pasteurization and grow in milk and cheese products to levels that result in defects. With the exception of meeting product specifications often required for milk powders, testing for specific spore-forming groups is currently not used in quality incentive programs in

  15. Characterization of composting mixtures and compost of rabbit by-products to obtain a quality product and plant proposal for industrial production.

    PubMed

    Bianchi, Biagio; Papajova, Ingrid; Tamborrino, Rosanna; Ventrella, Domenico; Vitti, Carolina

    2015-01-01

    In this study we have observed the effects of using rabbit manure and slaughtering by-products in a composting process. Three piles of this material, 4700 kg each, with different amount and C/N ratio, have been investigated and experimental tests were carried out in an industrial horizontal axe reactor using a prototype of turning machine. The composting time lasted 85 days; 2 experimental cycles were conducted: one in Winter and one in Summer. In the Winter test, mesophilic reaction started only in the control mixture (animal manure + slaughtering by-products without straw). It is noteworthy that, the 3 investigated mixtures produced soil amendment by compost with good agronomical potential but with parameters close to the extreme limits of the law. In the Summer test, there was thermophilic fermentation in all mixtures and a better quality compost was obtained, meeting all the agronomic and legislative constraints. For each pile, we examined the progression of fermentation process and thus the plant limitations that did not allow a correct composting process. The results obtained in this study are useful for the development of appropriate mixtures, machines, and plants assuring continuance and reliability in the composting of the biomass coming from rabbit industry.

  16. The Application of FT-IR Spectroscopy for Quality Control of Flours Obtained from Polish Producers

    PubMed Central

    Ceglińska, Alicja; Reder, Magdalena; Ciemniewska-Żytkiewicz, Hanna

    2017-01-01

    Samples of wheat, spelt, rye, and triticale flours produced by different Polish mills were studied by both classic chemical methods and FT-IR MIR spectroscopy. An attempt was made to statistically correlate FT-IR spectral data with reference data with regard to content of various components, for example, proteins, fats, ash, and fatty acids as well as properties such as moisture, falling number, and energetic value. This correlation resulted in calibrated and validated statistical models for versatile evaluation of unknown flour samples. The calibration data set was used to construct calibration models with use of the CSR and the PLS with the leave one-out, cross-validation techniques. The calibrated models were validated with a validation data set. The results obtained confirmed that application of statistical models based on MIR spectral data is a robust, accurate, precise, rapid, inexpensive, and convenient methodology for determination of flour characteristics, as well as for detection of content of selected flour ingredients. The obtained models' characteristics were as follows: R2 = 0.97, PRESS = 2.14; R2 = 0.96, PRESS = 0.69; R2 = 0.95, PRESS = 1.27; R2 = 0.94, PRESS = 0.76, for content of proteins, lipids, ash, and moisture level, respectively. Best results of CSR models were obtained for protein, ash, and crude fat (R2 = 0.86; 0.82; and 0.78, resp.). PMID:28243483

  17. Sci-Fri AM: Quality, Safety, and Professional Issues 01: CPQR Technical Quality Control Suite Development including Quality Control Workload Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Malkoske, Kyle; Nielsen, Michelle; Brown, Erika

    A close partnership between the Canadian Partnership for Quality Radiotherapy (CPQR) and the Canadian Organization of Medical Physicist’s (COMP) Quality Assurance and Radiation Safety Advisory Committee (QARSAC) has resulted in the development of a suite of Technical Quality Control (TQC) Guidelines for radiation treatment equipment, that outline specific performance objectives and criteria that equipment should meet in order to assure an acceptable level of radiation treatment quality. The framework includes consolidation of existing guidelines and/or literature by expert reviewers, structured stages of public review, external field-testing and ratification by COMP. The adopted framework for the development and maintenance of themore » TQCs ensures the guidelines incorporate input from the medical physics community during development, measures the workload required to perform the QC tests outlined in each TQC, and remain relevant (i.e. “living documents”) through subsequent planned reviews and updates. This presentation will show the Multi-Leaf Linear Accelerator document as an example of how feedback and cross-national work to achieve a robust guidance document. During field-testing, each technology was tested at multiple centres in a variety of clinic environments. As part of the defined feedback, workload data was captured. This lead to average time associated with testing as defined in each TQC document. As a result, for a medium-sized centre comprising 6 linear accelerators and a comprehensive brachytherapy program, we evaluate the physics workload to 1.5 full-time equivalent physicist per year to complete all QC tests listed in this suite.« less

  18. Airglow during ionospheric modifications by the sura facility radiation. experimental results obtained in 2010

    NASA Astrophysics Data System (ADS)

    Grach, S. M.; Klimenko, V. V.; Shindin, A. V.; Nasyrov, I. A.; Sergeev, E. N.; A. Yashnov, V.; A. Pogorelko, N.

    2012-06-01

    We present the results of studying the structure and dynamics of the HF-heated volume above the Sura facility obtained in 2010 by measurements of ionospheric airglow in the red (λ = 630 nm) and green (λ = 557.7 nm) lines of atomic oxygen. Vertical sounding of the ionosphere (followed by modeling of the pump-wave propagation) and measurements of stimulated electromagnetic emission were used for additional diagnostics of ionospheric parameters and the processes occurring in the heated volume.

  19. A comparison of sediment quality results with acid volatile sulfide (AVS) and simultaneously extracted metals (SEM) ratio in Vojvodina (Serbia) sediments.

    PubMed

    Prica, M; Dalmacija, B; Roncević, S; Krcmar, D; Becelić, M

    2008-01-25

    The acid-volatile sulfide (AVS), simultaneously extracted metals (SEM), total metals, and pore-water metal concentrations were studied in Vojvodina (Serbia) sediments. In Serbia, there are no regulations concerning sediment quality standards and sediment management. Harmonization of legislation in the domain of environmental protection with EU requirements will increase the significance of the sediment issue. Sediment quality was assessed according to Dutch standards, but the results were also compared with Canadian and USEPA (United States Environmental Protection Agency) guidelines for sediment quality. A comparison of the results based on different criteria for sediment quality assessment shows that they are sometimes contradictory. Therefore, a single approach to quality assessment may be insufficient. The Sigma[SEM]/[AVS] ratio was found to be greater than one at several locations that were already recognized as places of high risk based on Dutch standards. Some other samples had Sigma[SEM]/[AVS]<1, despite of the high risk classification based on the Dutch evaluation. However, not all sediments with Sigma[SEM]/[AVS]>1 can cause increased toxicity because there are many other metal-binding phases in sediments. Metals that are associated with AVS may be released within sediments through storms, dredging activities, oxidation, etc., and may have adverse environmental impacts. This has to be taken into account during dredging, which is for some sediments necessary because the sediment is of class 4 (Dutch evaluation), because the dredging process will certainly increase the concentration of bioavailable heavy metals and disturb the sedimentation dynamics. The obtained results will be invaluable for future activities regarding dredging and sediment management in the country.

  20. [Quality of life and job performance resulting from operatively treated tibial plateau fractures].

    PubMed

    Roßbach, B P; Faymonville, C; Müller, L P; Stützer, H; Isenberg, J

    2016-01-01

    The aim of this article is to present the functional results and the effect on quality of life of surgically treated tibial plateau fractures in physically active and working patients with multiple and serious injuries. In addition, the relationships between functional and radiological outcome were evaluated and compared with activity in daily and professional life. In all, 41 injured patients were followed up a mean of 47 months after surgical treatment and examined with radiological, functional, as well as quality of life score. In the radiological scoring, a mean value of 72 points (max 100 points) was achieved. In the activity score, there was an average of 63.5 points (max 100 points). When evaluating the health-related quality of life, an average score of 69.6 points was achieved. There was a significant relationship between radiological and activity scores and the radiological and life quality scores. Furthermore, the relationship between activity and quality of life scores was considered significant. Surgeon's influence on the functional outcome could be confirmed. The functional and the radiological results were moderate. Quality of life was permanently affected by the consequences of tibial plateau fracture in 12 patients; 11 patients were not re-employed. However, the quality of life was assessed as good or very good and 28 patients had returned to work. The quality of life was firmly linked to the radiological and functional parameters, which tended to be influenced by the quality of the primary surgical treatment when looking at the overall population.

  1. Quality of care for patients with diabetes mellitus type 2 in ‘model practices’ in Slovenia – first results

    PubMed Central

    Mlakar, Mitja

    2016-01-01

    Abstract Background A new organisation at the primary level, called model practices, introduces a 0.5 full-time equivalent nurse practitioner as a regular member of the team. Nurse practitioners are in charge of registers of chronic patients, and implement an active approach into medical care. Selected quality indicators define the quality of management. The majority of studies confirm the effectiveness of the extended team in the quality of care, which is similar or improved when compared to care performed by the physician alone. The aim of the study is to compare the quality of management of patients with diabetes mellitus type 2 before and after the introduction of model practices. Methods A cohort retrospective study was based on medical records from three practices. Process quality indicators, such as regularity of HbA1c measurement, blood pressure measurement, foot exam, referral to eye exam, performance of yearly laboratory tests and HbA1c level before and after the introduction of model practices were compared. Results The final sample consisted of 132 patients, whose diabetes care was exclusively performed at the primary care level. The process of care has significantly improved after the delivery of model practices. The most outstanding is the increase of foot exam and HbA1c testing. We could not prove better glycaemic control (p>0.1). Nevertheless, the proposed benchmark for the suggested quality process and outcome indicators were mostly exceeded in this cohort. Conclusion The introduction of a nurse into the team improves the process quality of care. Benchmarks for quality indicators are obtainable. Better outcomes of care need further confirmation. PMID:27703537

  2. Phase quality map based on local multi-unwrapped results for two-dimensional phase unwrapping.

    PubMed

    Zhong, Heping; Tang, Jinsong; Zhang, Sen

    2015-02-01

    The efficiency of a phase unwrapping algorithm and the reliability of the corresponding unwrapped result are two key problems in reconstructing the digital elevation model of a scene from its interferometric synthetic aperture radar (InSAR) or interferometric synthetic aperture sonar (InSAS) data. In this paper, a new phase quality map is designed and implemented in a graphic processing unit (GPU) environment, which greatly accelerates the unwrapping process of the quality-guided algorithm and enhances the correctness of the unwrapped result. In a local wrapped phase window, the center point is selected as the reference point, and then two unwrapped results are computed by integrating in two different simple ways. After the two local unwrapped results are computed, the total difference of the two unwrapped results is regarded as the phase quality value of the center point. In order to accelerate the computing process of the new proposed quality map, we have implemented it in a GPU environment. The wrapped phase data are first uploaded to the memory of a device, and then the kernel function is called in the device to compute the phase quality in parallel by blocks of threads. Unwrapping tests performed on the simulated and real InSAS data confirm the accuracy and efficiency of the proposed method.

  3. [Practice report: the process-based indicator dashboard. Visualising quality assurance results in standardised processes].

    PubMed

    Petzold, Thomas; Hertzschuch, Diana; Elchlep, Frank; Eberlein-Gonska, Maria

    2014-01-01

    Process management (PM) is a valuable method for the systematic analysis and structural optimisation of the quality and safety of clinical treatment. PM requires a high motivation and willingness to implement changes of both employees and management. Definition of quality indicators is required to systematically measure the quality of the specified processes. One way to represent comparable quality results is the use of quality indicators of the external quality assurance in accordance with Sect. 137 SGB V—a method which the Federal Joint Committee (GBA) and the institutions commissioned by the GBA have employed and consistently enhanced for more than ten years. Information on the quality of inpatient treatment is available for 30 defined subjects throughout Germany. The combination of specified processes with quality indicators is beneficial for the information of employees. A process-based indicator dashboard provides essential information about the treatment process. These can be used for process analysis. In a continuous consideration of these indicator results values can be determined and errors will be remedied quickly. If due consideration is given to these indicators, they can be used for benchmarking to identify potential process improvements. Copyright © 2014. Published by Elsevier GmbH.

  4. Effect of using different cover image quality to obtain robust selective embedding in steganography

    NASA Astrophysics Data System (ADS)

    Abdullah, Karwan Asaad; Al-Jawad, Naseer; Abdulla, Alan Anwer

    2014-05-01

    One of the common types of steganography is to conceal an image as a secret message in another image which normally called a cover image; the resulting image is called a stego image. The aim of this paper is to investigate the effect of using different cover image quality, and also analyse the use of different bit-plane in term of robustness against well-known active attacks such as gamma, statistical filters, and linear spatial filters. The secret messages are embedded in higher bit-plane, i.e. in other than Least Significant Bit (LSB), in order to resist active attacks. The embedding process is performed in three major steps: First, the embedding algorithm is selectively identifying useful areas (blocks) for embedding based on its lighting condition. Second, is to nominate the most useful blocks for embedding based on their entropy and average. Third, is to select the right bit-plane for embedding. This kind of block selection made the embedding process scatters the secret message(s) randomly around the cover image. Different tests have been performed for selecting a proper block size and this is related to the nature of the used cover image. Our proposed method suggests a suitable embedding bit-plane as well as the right blocks for the embedding. Experimental results demonstrate that different image quality used for the cover images will have an effect when the stego image is attacked by different active attacks. Although the secret messages are embedded in higher bit-plane, but they cannot be recognised visually within the stegos image.

  5. [Effect of a multidisciplinar protocol on the clinical results obtained after bariatric surgery].

    PubMed

    Cánovas Gaillemin, B; Sastre Martos, J; Moreno Segura, G; Llamazares Iglesias, O; Familiar Casado, C; Abad de Castro, S; López Pardo, R; Sánchez-Cabezudo Muñoz, M A

    2011-01-01

    Bariatric surgery has been shown to be an effective therapy for weight loss in patients with severe obesity, and the implementation of a multidisciplinar management protocol is recommended. To assess the usefulness of the implementation of a management protocol in obesity surgery based on the Spanish Consensus Document of the SEEDO. Retrospective comparative study of the outcomes in patients previously operated (51 patients) and after the implementation of the protocol (66 patients). The following data were gathered: anthropometry, pre-and post-surgery comorbidities, post-surgical nutritional and surgical complications, validated Quality of Life questionnaire, and dietary habits. Withdrawals (l7.6%) and alcoholism (5.8%) were higher in patients pre- versus post-implementation of the protocol (4.5% vs. 3%, respectively), the differences being statistically significant. The mortality rate was 2% in the pre-protocol group and 0% in the postprotocol group. The dietary habits were better in the post-protocol group, the pre-protocol group presenting a higher percentage of feeding-behavior disorders (5.1%) although not reaching a statistical significance. The improvement in quality of life was higher in the post-protocol group for all items, but only reaching statistical significance in sexual activity (p = 0.004). In the pre-protocol group, 70.5% of the patients had more than one nutritional complication vs. 32.8% in the post-protocol group (p < 0.05). There were no differences regarding the percentage of weight in excess lost at two years (> 50% in 81.3% in the pre-protocol group vs. 74.8% in the pos-protocol group) or the comorbidities. Bariatric surgery achieves excellent outcomes in weight loss, comorbidities, and quality of life, but presents nutritional, surgical, and psychiatric complications that require a protocol-based and multidisciplinary approach. Our protocol improves the outcomes regarding the withdrawal rates, feeding-behavior disorders, dietary habits

  6. Mass imbalances in EPANET water-quality simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, Michael J.; Janke, Robert; Taxon, Thomas N.

    EPANET is widely employed to simulate water quality in water distribution systems. However, the time-driven simulation approach used to determine concentrations of water-quality constituents provides accurate results, in general, only for small water-quality time steps; use of an adequately short time step may not be feasible. Overly long time steps can yield errors in concentrations and result in situations in which constituent mass is not conserved. Mass may not be conserved even when EPANET gives no errors or warnings. This paper explains how such imbalances can occur and provides examples of such cases; it also presents a preliminary event-driven approachmore » that conserves mass with a water-quality time step that is as long as the hydraulic time step. Results obtained using the current approach converge, or tend to converge, to those obtained using the new approach as the water-quality time step decreases. Improving the water-quality routing algorithm used in EPANET could eliminate mass imbalances and related errors in estimated concentrations.« less

  7. Study of geomorphological changes by high quality DEMs, obtained from UAVs-Structure from Motion in highest continental cliffs of Europe: A Capelada (Galicia, Spain)

    NASA Astrophysics Data System (ADS)

    Muñoz Narciso, Efrén; García, Horacio; Sierra Pernas, Chema; Pérez-Alberti, Augusto

    2017-04-01

    This study analyses the geomorphological evolution of a highly dynamic coastal environment, one of the higher cliffs in Continental Europe (A Capelada, NW Spain), using Structure from Motion-Multi View Stereoscan techniques (hereafter referred to as SfM-MVS). Comparing orthoimages from the last 10 years we observed several topographical changes in one specific valley (Teixidelo). Interestingly, these changes were caused by 2 different processes: (i) heavy coastal erosion and (ii) slow complex landslides, working in opposite directions. The main challenge was obtaining high quality topographical data for quantifying the changes during the last few years using low cost-high quality techniques in remote areas. Unmanned Aerial Vehicle platforms (drones, hereafter referred to as UAVs) and SFM-MVS offer ultrahigh-density topographical data. Furthermore, the use of drones and SfM-MVS close range images requires new applications in geomorphology for understanding the workflow and limitations. In this paper we present the 2 main results: (i) a centimeter spatial resolution DEM from august 2016 was obtained using a @DJI Phantom 3 advanced model drone. The pictures were processed in Agisoft PhotoScan Pro 1.2.6 version by SfM-MVS techniques, generating a high-density point cloud (i.e. ˜2000 points/m2) with 3mm of RMSE (i.e. the point cloud was georeferenced in a geographical coordinates system using ˜40 Ground Control Points obtained from differential RTK-GPS and a Total Station network) and (ii) a DEM of Differences, which compares official freely available 2010 LiDAR data (i.e. ˜2 points/m2) with a 2016 DEM derived by UAVs-SfM, where we have observed meter-scale elevation changes (i.e. sediment and erosion processes). During this time, 75% of the sediment has been mobilized. The novel UAVs and SfM-MVS techniques prove to be great for advancing the study of geomorphological processes in remote areas.

  8. Groundwater Quality Data for the Northern Sacramento Valley, 2007: Results from the California GAMA Program

    USGS Publications Warehouse

    Bennett, Peter A.; Bennett, George L.; Belitz, Kenneth

    2009-01-01

    to 11 percent of the wells, and the results for these samples were used to evaluate the quality of the data obtained from the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a noticeable source of bias in the data for the groundwater samples. Differences between replicate samples were within acceptable ranges for nearly all compounds, indicating acceptably low variability. Matrix-spike recoveries were within acceptable ranges for most compounds. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, raw groundwater typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw groundwater were compared with regulatory and nonregulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH) and with aesthetic and technical thresholds established by CDPH. Comparisons between data collected for this study and drinking-water thresholds are for illustrative purposes only and do not indicate compliance or noncompliance with those thresholds. The concentrations of most constituents detected in groundwater samples from REDSAC were below drinking-water thresholds. Volatile organic compounds (VOC) and pesticides were detected in less than one-quarter of the samples and were generally less than a hundredth of any health-based thresholds. NDMA was detected in one grid well above the NL-CA. Concentrations of all nutrients and trace elements in samples from REDSAC wells were below the health-based thresholds except those of arsenic in three samples, which were above the USEPA maximum contaminant level (MCL-US). However

  9. Mass imbalances in EPANET water-quality simulations

    NASA Astrophysics Data System (ADS)

    Davis, Michael J.; Janke, Robert; Taxon, Thomas N.

    2018-04-01

    EPANET is widely employed to simulate water quality in water distribution systems. However, in general, the time-driven simulation approach used to determine concentrations of water-quality constituents provides accurate results only for short water-quality time steps. Overly long time steps can yield errors in concentration estimates and can result in situations in which constituent mass is not conserved. The use of a time step that is sufficiently short to avoid these problems may not always be feasible. The absence of EPANET errors or warnings does not ensure conservation of mass. This paper provides examples illustrating mass imbalances and explains how such imbalances can occur because of fundamental limitations in the water-quality routing algorithm used in EPANET. In general, these limitations cannot be overcome by the use of improved water-quality modeling practices. This paper also presents a preliminary event-driven approach that conserves mass with a water-quality time step that is as long as the hydraulic time step. Results obtained using the current approach converge, or tend to converge, toward those obtained using the preliminary event-driven approach as the water-quality time step decreases. Improving the water-quality routing algorithm used in EPANET could eliminate mass imbalances and related errors in estimated concentrations. The results presented in this paper should be of value to those who perform water-quality simulations using EPANET or use the results of such simulations, including utility managers and engineers.

  10. Monitoring the Quality of Medicines: Results from Africa, Asia, and South America

    PubMed Central

    Hajjou, Mustapha; Krech, Laura; Lane-Barlow, Christi; Roth, Lukas; Pribluda, Victor S.; Phanouvong, Souly; El-Hadri, Latifa; Evans, Lawrence; Raymond, Christopher; Yuan, Elaine; Siv, Lang; Vuong, Tuan-Anh; Boateng, Kwasi Poku; Okafor, Regina; Chibwe, Kennedy M.; Lukulay, Patrick H.

    2015-01-01

    Monitoring the quality of medicines plays a crucial role in an integrated medicines quality assurance system. In a publicly available medicines quality database (MQDB), the U.S. Pharmacopeial Convention (USP) reports results of data collected from medicines quality monitoring (MQM) activities spanning the period of 2003–2013 in 17 countries of Africa, Asia, and South America. The MQDB contains information on 15,063 samples collected and tested using Minilab® screening methods and/or pharmacopeial methods. Approximately 71% of the samples reported came from Asia, 23% from Africa, and 6% from South America. The samples collected and tested include mainly antibiotic, antimalarial, and antituberculosis medicines. A total of 848 samples, representing 5.6% of total samples, failed the quality test. The failure proportion per region was 11.5%, 10.4%, and 2.9% for South America, Africa, and Asia, respectively. Eighty-one counterfeit medicines were reported, 86.4% of which were found in Asia and 13.6% in Africa. Additional analysis of the data shows the distribution of poor-quality medicines per region and by therapeutic indication as well as possible trends of counterfeit medicines. PMID:25897073

  11. Institutional Consequences of Quality Assessment

    ERIC Educational Resources Information Center

    Joao Rosa, Maria; Tavares, Diana; Amaral, Alberto

    2006-01-01

    This paper analyses the opinions of Portuguese university rectors and academics on the quality assessment system and its consequences at the institutional level. The results obtained show that university staff (rectors and academics, with more of the former than the latter) held optimistic views of the positive consequences of quality assessment…

  12. Evaluation of Adherence to Quality Measures for Prostate Cancer Radiotherapy in the United States: Results from the Quality Research in Radiation Oncology (QRRO) Survey.

    PubMed

    Zelefsky, Michael J; Lee, W Robert; Zietman, Anthony; Khalid, Najma; Crozier, Cheryl; Owen, Jean; Wilson, J Frank

    2013-01-01

    To test the feasibility of using proposed quality indicators to assess radiotherapy quality in prostate cancer management based on a 2007 stratified random survey of treating academic and non-academic US institutions. 414 patients with clinically localized prostate cancer treated with external beam radiotherapy (EBRT) or brachytherapy were selected from 45 institutions. Indicators used as specific measurable clinical performance measures to represent surrogates for quality of radiotherapy delivery included established measures, such as the use of prescription doses ≥75 Gy for intermediate- and high-risk EBRT patients and androgen-deprivation therapy (ADT) in conjunction with EBRT for patients with high-risk disease, and emerging measures, including daily target localization (image-guidance) to correct for organ motion for EBRT patients. 167 patients (47%) were treated with 6 MV photons, 31 (9%) were treated with 10 MV, 65 (18%) received 15 MV, and the remaining 90 (26%) 16-23 MV. For intermediate- plus high-risk patients (n=181), 78% were treated to ≥75 Gy. Among favorable-risk patients, 72% were treated to ≥75 Gy. Among high-risk EBRT patients, 60 (87%) were treated with ADT in conjunction with EBRT and 13% (n=9) with radiotherapy alone. Among low- and intermediate-risk patients, 10% and 42%, respectively, were treated with ADT plus EBRT. For 24% of EBRT patients (85/354), weekly electronic portal imaging was obtained as verification films without daily target localization and the remaining 76% were treated with daily localization of the target using various methods. Adherence to defined quality indicators was observed in a majority of patients. ≈90% of high-risk patients are treated with ADT plus EBRT and ≈80% of intermediate- and high-risk patients receive prescription doses >=75 Gy, consistent with the published results of randomized trials.

  13. POSNA Quality Safety Value Initiative: From Vision to Implementation to Early Results.

    PubMed

    Waters, Peter M; Flynn, John M

    2015-01-01

    The POSNA Quality, Safety and Value Initiative (QSVI) formally started with POSNA board approval in early 2011. The initial vision statement was: "To lead in defining our members' value based clinical care. To partner with hospital based and orthopedic organizational efforts to guarantee safe, high quality outcomes for our patients. To communicate our initiatives and results cooperatively with payer, credentialing, and compliance organizations to improve pediatric orthopedic care in North America."

  14. Optimization of the parameters for obtaining zirconia-alumina coatings, made by flame spraying from results of numerical simulation

    NASA Astrophysics Data System (ADS)

    Ferrer, M.; Vargas, F.; Peña, G.

    2017-12-01

    The K-Sommerfeld values (K) and the melting percentage (% F) obtained by numerical simulation using the Jets et Poudres software were used to find the projection parameters of zirconia-alumina coatings by thermal spraying flame, in order to obtain coatings with good morphological and structural properties to be used as thermal insulation. The experimental results show the relationship between the Sommerfeld parameter and the porosity of the zirconia-alumina coatings. It is found that the lowest porosity is obtained when the K-Sommerfeld value is close to 45 with an oxidant flame, on the contrary, when superoxidant flames are used K values are close 52, which improve wear resistance.

  15. The Impact of Applying Quality Management Practices on Patient Centeredness in Jordanian Public Hospitals: Results of Predictive Modeling

    PubMed Central

    Hijazi, Heba H.; Harvey, Heather L.; Alyahya, Mohammad S.; Alshraideh, Hussam A.; Al abdi, Rabah M.; Parahoo, Sanjai K.

    2018-01-01

    Targeting the patient’s needs and preferences has become an important contributor for improving care delivery, enhancing patient satisfaction, and achieving better clinical outcomes. This study aimed to examine the impact of applying quality management practices on patient centeredness within the context of health care accreditation and to explore the differences in the views of various health care workers regarding the attributes affecting patient-centered care. Our study followed a cross-sectional survey design wherein 4 Jordanian public hospitals were investigated several months after accreditation was obtained. Total 829 clinical/nonclinical hospital staff members consented for study participation. This sample was divided into 3 main occupational categories to represent the administrators, nurses, as well as doctors and other health professionals. Using a structural equation modeling, our results indicated that the predictors of patient-centered care for both administrators and those providing clinical care were participation in the accreditation process, leadership commitment to quality improvement, and measurement of quality improvement outcomes. In particular, perceiving the importance of the hospital’s engagement in the accreditation process was shown to be relevant to the administrators (gamma = 0.96), nurses (gamma = 0.80), as well as to doctors and other health professionals (gamma = 0.71). However, the administrator staff (gamma = 0.31) was less likely to perceive the influence of measuring the quality improvement outcomes on the delivery of patient-centered care than nurses (gamma = 0.59) as well as doctors and other health care providers (gamma = 0.55). From the nurses’ perspectives only, patient centeredness was found to be driven by building an institutional framework that supports quality assurance in hospital settings (gamma = 0.36). In conclusion, accreditation is a leading factor for delivering patient-centered care and should be on a

  16. The Impact of Applying Quality Management Practices on Patient Centeredness in Jordanian Public Hospitals: Results of Predictive Modeling.

    PubMed

    Hijazi, Heba H; Harvey, Heather L; Alyahya, Mohammad S; Alshraideh, Hussam A; Al Abdi, Rabah M; Parahoo, Sanjai K

    2018-01-01

    Targeting the patient's needs and preferences has become an important contributor for improving care delivery, enhancing patient satisfaction, and achieving better clinical outcomes. This study aimed to examine the impact of applying quality management practices on patient centeredness within the context of health care accreditation and to explore the differences in the views of various health care workers regarding the attributes affecting patient-centered care. Our study followed a cross-sectional survey design wherein 4 Jordanian public hospitals were investigated several months after accreditation was obtained. Total 829 clinical/nonclinical hospital staff members consented for study participation. This sample was divided into 3 main occupational categories to represent the administrators, nurses, as well as doctors and other health professionals. Using a structural equation modeling, our results indicated that the predictors of patient-centered care for both administrators and those providing clinical care were participation in the accreditation process, leadership commitment to quality improvement, and measurement of quality improvement outcomes. In particular, perceiving the importance of the hospital's engagement in the accreditation process was shown to be relevant to the administrators (gamma = 0.96), nurses (gamma = 0.80), as well as to doctors and other health professionals (gamma = 0.71). However, the administrator staff (gamma = 0.31) was less likely to perceive the influence of measuring the quality improvement outcomes on the delivery of patient-centered care than nurses (gamma = 0.59) as well as doctors and other health care providers (gamma = 0.55). From the nurses' perspectives only, patient centeredness was found to be driven by building an institutional framework that supports quality assurance in hospital settings (gamma = 0.36). In conclusion, accreditation is a leading factor for delivering patient-centered care and should be on a hospital

  17. Analysis of the impact of simulation model simplifications on the quality of low-energy buildings simulation results

    NASA Astrophysics Data System (ADS)

    Klimczak, Marcin; Bojarski, Jacek; Ziembicki, Piotr; Kęskiewicz, Piotr

    2017-11-01

    The requirements concerning energy performance of buildings and their internal installations, particularly HVAC systems, have been growing continuously in Poland and all over the world. The existing, traditional calculation methods following from the static heat exchange model are frequently not sufficient for a reasonable heating design of a building. Both in Poland and elsewhere in the world, methods and software are employed which allow a detailed simulation of the heating and moisture conditions in a building, and also an analysis of the performance of HVAC systems within a building. However, these systems are usually difficult in use and complex. In addition, the development of a simulation model that is sufficiently adequate to the real building requires considerable time involvement of a designer, is time-consuming and laborious. A simplification of the simulation model of a building renders it possible to reduce the costs of computer simulations. The paper analyses in detail the effect of introducing a number of different variants of the simulation model developed in Design Builder on the quality of final results obtained. The objective of this analysis is to find simplifications which allow obtaining simulation results which have an acceptable level of deviations from the detailed model, thus facilitating a quick energy performance analysis of a given building.

  18. Process quality indicators in family medicine: results of an international comparison.

    PubMed

    Pavlič, Danica Rotar; Sever, Maja; Klemenc-Ketiš, Zalika; Švab, Igor

    2015-12-02

    The aim of our study was to describe variability in process quality in family medicine among 31 European countries plus Australia, New Zealand, and Canada. The quality of family medicine was measured in terms of continuity, coordination, community orientation, and comprehensiveness of care. The QUALICOPC study (Quality and Costs of Primary Care in Europe) was carried out among family physicians in 31 European countries (the EU 27 except for France, plus Macedonia, Iceland, Norway, Switzerland, and Turkey) and three non-European countries (Australia, Canada, and New Zealand). We used random sampling when national registers of practitioners were available. Regional registers or lists of facilities were used for some countries. A standardized questionnaire was distributed to the physicians, resulting in a sample of 6734 participants. Data collection took place between October 2011 and December 2013. Based on completed questionnaires, a three-dimensional framework was established to measure continuity, coordination, community orientation, and comprehensiveness of care. Multilevel linear regression analysis was performed to evaluate the variation of quality attributable to the family physician level and the country level. None of the 34 countries in this study consistently scored the best or worst in all categories. Continuity of care was perceived by family physicians as the most important dimension of quality. Some components of comprehensiveness of care, including medical technical procedures, preventive care and health care promotion, varied substantially between countries. Coordination of care was identified as the weakest part of quality. We found that physician-level characteristics contributed to the majority of variation. A comparison of process quality indicators in family medicine revealed similarities and differences within and between countries. The researchers found that the major proportion of variation can be explained by physicians' characteristics.

  19. Quality of life after TIA and stroke: ten-year results of the Oxford Vascular Study.

    PubMed

    Luengo-Fernandez, Ramon; Gray, Alastair M; Bull, Linda; Welch, Sarah; Cuthbertson, Fiona; Rothwell, Peter M

    2013-10-29

    To evaluate the 5-year impact of stroke and TIA on utility and quality-adjusted survival. TIA and stroke patients from a UK population-based study (Oxford Vascular Study) were recruited from 2002 to 2007, and followed up until 2012. Quality of life was assessed over 5 years using the EQ-5D (EuroQol-5 Dimensions), with responses converted into utilities ranging from -0.59 (worse than death) to 1 (perfect health), using UK population valuations. Utilities for stroke and TIA patients were compared with those in matched controls obtained from the 2006 Health Survey for England. Five-year quality-adjusted life years were estimated by combining utility and survival information. Four hundred forty TIA and 748 stroke patients were ascertained and included. Utility remained constant at approximately 0.78 over the 5 years after TIA. Utility improved from 0.64 one month after stroke to 0.70 at 6 months (p = 0.006), remaining at approximately 0.70 thereafter. Matched controls had considerably higher utility levels than stroke/TIA patients (0.85, p < 0.001). Event severity and recurrent stroke were significant predictors of decreased long-term utility. Five-year quality-adjusted life expectancy was 3.32 (95% confidence interval: 3.22-3.48) quality-adjusted life years after TIA and 2.21 (2.15-2.37) after stroke, varying considerably by severity (minor: 2.94; moderate: 1.65; and severe: 0.70). Quality-adjusted survival is low over the 5 years after stroke and TIA, with severity and recurrent stroke being major predictors. There remains considerable scope for improvements in acute treatment and secondary prevention to improve the quality of life after TIA and stroke.

  20. [Active ageing and quality of life--Results of a WHO demonstration project].

    PubMed

    von dem Knesebeck, O; David, K; Bill, P; Hikl, R

    2006-04-01

    Based on the Active Ageing Programme of the World Health Organization (WHO), a demonstration project was conducted in a city in North-Rhine Westphalia between October 2002 and December 2004. The aim of the study was to promote an active ageing process, to maintain autonomy and independence among older people, and thereby to promote health and quality of life. The target group included people aged 55 to 80 years. The aim was to include older persons in a critical period of life due to loss of partner within the last five years and people undergoing a status change due to retirement within the last two years. 344 participants were visited at home to assess their health and psychosocial situation and to identify opportunities for activities. Participants were supported in their efforts to realise the agreed-upon activities. In this article results of the external evaluation are presented. It is analysed whether quality of life according to the WHOQOL Bref improves among participants in the course of the project. Results of non-parametric tests show small differences in quality of life between the three waves of interviews (at the beginning of the project, after one year, at the end of the project). This holds true when only those participants are analysed who retired within the last two years. However, quality of life significantly improves among older persons who lost their partner within the last five years. In terms of implementation of the WHO Active Ageing Programme results suggest application of a risk group strategy.

  1. New high-definition thickness data obtained at tropical glaciers: preliminary results from Antisana volcano (Ecuador) using GPR prospection

    NASA Astrophysics Data System (ADS)

    Zapata, Camilo; Andrade, Daniel; Córdova, Jorge; Maisincho, Luis; Carvajal, Juan; Calispa, Marlon; Villacís, Marcos

    2014-05-01

    The study of tropical glaciers has been a significant contribution to the understanding of glacier dynamics and climate change. Much of the data and results have been obtained by analyzing plan-view images obtained by air- and space-borne sensors, as well as depth data obtained by diverse methodologies at selected points on the glacier surface. However, the measurement of glacier thicknesses has remained an elusive task in tropical glaciers, often located in rough terrains where the application of geophysical surveys (i.e. seismic surveys) requires logistics sometimes hardly justified by the amount of obtained data. In the case of Ecuador, however, where most glaciers have developed on active volcanoes and represent sources/reservoirs of fresh water, the precise knowledge of such information is fundamental for scientific research but also in order to better assess key aspects for the society. The relatively recent but fast development of the GPR technology has helped to obtain new highdefinition thickness data at Antisana volcano that will be used to: 1) better understand the dynamics and fate of tropical glaciers; 2) better estimate the amount of fresh water stored in the glaciers; 3) better assess the hazards associated with the sudden widespread melting of glaciers during volcanic eruptions. The measurements have been obtained at glaciers 12 and 15 of Antisana volcano, with the help of a commercial GPR equipped with a 25 MHz antenna. A total of 30 transects have been obtained, covering a distance of more than 3 km, from the glacier ablation zone, located at ~ 4600 masl, up to the level of 5200 masl. The preliminary results show a positive correlation between altitude and glacier thickness, with maximum and minimum calculated values reaching up to 80 m, and down to 15 m, respectively. The experience gained at Antisana volcano will be used to prepare a more widespread GPR survey in the glaciers of Cotopaxi volcano, whose implications in terms of volcanic hazards

  2. Groundwater-Quality Data in the Madera-Chowchilla Study Unit, 2008: Results from the California GAMA Program

    USGS Publications Warehouse

    Shelton, Jennifer L.; Fram, Miranda S.; Belitz, Kenneth

    2009-01-01

    , oxygen, and carbon, and activities of tritium and carbon-14), and dissolved noble gases also were measured to help identify the sources and ages of the sampled groundwater. In total, approximately 300 constituents and field water-quality indicators were investigated. Three types of quality-control samples (blanks, replicates, and samples for matrix spikes) each were collected at approximately 11 percent of the wells sampled for each analysis, and the results obtained from these samples were used to evaluate the quality of the data for the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that data for the groundwater samples were not compromised by possible contamination during sample collection, handling or analysis. Differences between replicate samples were within acceptable ranges. Matrix spike recoveries were within acceptable ranges for most compounds. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, raw groundwater typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to raw groundwater. However, to provide some context for the results, concentrations of constituents measured in the raw groundwater were compared with regulatory and non-regulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and the California Department of Public Health (CDPH), and with aesthetic and technical thresholds established by CDPH. Comparisons between data collected for this study and drinking-water thresholds are for illustrative purposes only, and are not indicative of compliance or non-compliance with regulatory thresholds. The concentrations of most constituents detected in groundwater samples from MADCHOW wells were below drinking-water thresholds. Organic compounds (VOCs and pesticides

  3. Assuring the Quality of Test Results in the Field of Nuclear Techniques and Ionizing Radiation. The Practical Implementation of Section 5.9 of the EN ISO/IEC 17025 Standard

    NASA Astrophysics Data System (ADS)

    Cucu, Daniela; Woods, Mike

    2008-08-01

    The paper aims to present a practical approach for testing laboratories to ensure the quality of their test results. It is based on the experience gained in assessing a large number of testing laboratories, discussing with management and staff, reviewing results obtained in national and international PTs and ILCs and exchanging information in the EA laboratory committee. According to EN ISO/IEC 17025, an accredited laboratory has to implement a programme to ensure the quality of its test results for each measurand. Pre-analytical, analytical and post-analytical measures shall be applied in a systematic manner. They shall include both quality control and quality assurance measures. When designing the quality assurance programme a laboratory should consider pre-analytical activities (like personnel training, selection and validation of test methods, qualifying equipment), analytical activities ranging from sampling, sample preparation, instrumental analysis and post-analytical activities (like decoding, calculation, use of statistical tests or packages, management of results). Designed on different levels (analyst, quality manager and technical manager), including a variety of measures, the programme shall ensure the validity and accuracy of test results, the adequacy of the management system, prove the laboratory's competence in performing tests under accreditation and last but not least show the comparability of test results. Laboratory management should establish performance targets and review periodically QC/QA results against them, implementing appropriate measures in case of non-compliance.

  4. How does study quality affect the results of a diagnostic meta-analysis?

    PubMed Central

    Westwood, Marie E; Whiting, Penny F; Kleijnen, Jos

    2005-01-01

    Background The use of systematic literature review to inform evidence based practice in diagnostics is rapidly expanding. Although the primary diagnostic literature is extensive, studies are often of low methodological quality or poorly reported. There has been no rigorously evaluated, evidence based tool to assess the methodological quality of diagnostic studies. The primary objective of this study was to determine the extent to which variations in the quality of primary studies impact the results of a diagnostic meta-analysis and whether this differs with diagnostic test type. A secondary objective was to contribute to the evaluation of QUADAS, an evidence-based tool for the assessment of quality in diagnostic accuracy studies. Methods This study was conducted as part of large systematic review of tests used in the diagnosis and further investigation of urinary tract infection (UTI) in children. All studies included in this review were assessed using QUADAS, an evidence-based tool for the assessment of quality in systematic reviews of diagnostic accuracy studies. The impact of individual components of QUADAS on a summary measure of diagnostic accuracy was investigated using regression analysis. The review divided the diagnosis and further investigation of UTI into the following three clinical stages: diagnosis of UTI, localisation of infection, and further investigation of the UTI. Each stage used different types of diagnostic test, which were considered to involve different quality concerns. Results Many of the studies included in our review were poorly reported. The proportion of QUADAS items fulfilled was similar for studies in different sections of the review. However, as might be expected, the individual items fulfilled differed between the three clinical stages. Regression analysis found that different items showed a strong association with test performance for the different tests evaluated. These differences were observed both within and between the three

  5. Does bacteriology laboratory automation reduce time to results and increase quality management?

    PubMed

    Dauwalder, O; Landrieve, L; Laurent, F; de Montclos, M; Vandenesch, F; Lina, G

    2016-03-01

    Due to reductions in financial and human resources, many microbiological laboratories have merged to build very large clinical microbiology laboratories, which allow the use of fully automated laboratory instruments. For clinical chemistry and haematology, automation has reduced the time to results and improved the management of laboratory quality. The aim of this review was to examine whether fully automated laboratory instruments for microbiology can reduce time to results and impact quality management. This study focused on solutions that are currently available, including the BD Kiestra™ Work Cell Automation and Total Lab Automation and the Copan WASPLab(®). Copyright © 2015 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  6. Explaining variation in perceived team effectiveness: results from eleven quality improvement collaboratives.

    PubMed

    Strating, Mathilde M H; Nieboer, Anna P

    2013-06-01

    Explore effectiveness of 11 collaboratives focusing on 11 different topics, as perceived by local improvement teams and to explore associations with collaborative-, organisational- and team-level factors. Evidence underlying the effectiveness of quality improvement collaboratives is inconclusive and few studies investigated determinants of implementation success. Moreover, most evaluation studies on quality improvement collaboratives are based on one specific topic or quality problem, making it hard to compare across collaboratives addressing different topics. A multiple-case cross-sectional study. Quality improvement teams in 11 quality improvement collaboratives focusing on 11 different topics. Team members received a postal questionnaire at the end of each collaborative. Of the 283 improvement teams, 151 project leaders and 362 team members returned the questionnaire. Analysis of variance revealed that teams varied widely on perceived effectiveness. Especially, members in the Prevention of Malnutrition and Prevention of Medication Errors collaboratives perceived a higher effectiveness than other groups. Multilevel regression analyses showed that educational level of professionals, innovation attributes, organisational support, innovative culture and commitment to change were all significant predictors of perceived effectiveness. In total, 27·9% of the individual-level variance, 57·6% of the team-level variance and 80% of the collaborative-level variance could be explained. The innovation's attributes, organisational support, an innovative team culture and professionals' commitment to change are instrumental to perceived effectiveness. The results support the notion that a layered approach is necessary to achieve improvements in quality of care and provides further insight in the determinants of success of quality improvement collaboratives. Understanding which factors enhance the impact of quality improvement initiatives can help professionals to achieve

  7. Quality of life following hip fractures: results from the Norwegian hip fracture register.

    PubMed

    Gjertsen, Jan-Erik; Baste, Valborg; Fevang, Jonas M; Furnes, Ove; Engesæter, Lars Birger

    2016-07-07

    Patient-reported health-related quality of life is an important outcome measure when assessing the quality of hip fracture surgery. The frequently used EQ-5D index score has unfortunately important limitations. One alternative can be to assess the distribution of each of the five dimensions of the patients' descriptive health profile. The objective of this paper was to investigate health-related quality of life (HRQoL) after hip fractures. Data from hip fracture operations from 2005 through 2012 were obtained from The Norwegian Hip Fracture Register. Patient reported HRQoL, (EQ-5D-3L) was collected from patients preoperatively and at four and twelve months postoperatively n = 10325. At each follow-up the distribution of the EQ-5D-3L and mean pain VAS was calculated. Generally, a higher proportion of patients reported problems in all 5 dimensions of the EQ-5D-3L at all follow-ups compared to preoperative. Also a high proportion of patients with no preoperative problems reported problems after surgery; At 4 and 12 months follow-ups 71 % and 58 % of the patients reported walking problems, and 65 % and 59 % of the patients reported pain respectively. Patients with femoral neck fractures and the youngest patients (age < 70 years) reported least problems both preoperatively and at all follow-ups. A hip fracture has a dramatic impact on the patients' HRQoL, and the deterioration in HRQoL sustained also one year after the fracture. Separate use of the descriptive profile of the EQ-5D is informative when assessing quality of life after hip fracture surgery.

  8. Interim results of quality-control sampling of surface water for the Upper Colorado River National Water-Quality Assessment Study Unit, water years 1995-96

    USGS Publications Warehouse

    Spahr, N.E.; Boulger, R.W.

    1997-01-01

    Quality-control samples provide part of the information needed to estimate the bias and variability that result from sample collection, processing, and analysis. Quality-control samples of surface water collected for the Upper Colorado River National Water-Quality Assessment study unit for water years 1995?96 are presented and analyzed in this report. The types of quality-control samples collected include pre-processing split replicates, concurrent replicates, sequential replicates, post-processing split replicates, and field blanks. Analysis of the pre-processing split replicates, concurrent replicates, sequential replicates, and post-processing split replicates is based on differences between analytical results of the environmental samples and analytical results of the quality-control samples. Results of these comparisons indicate that variability introduced by sample collection, processing, and handling is low and will not affect interpretation of the environmental data. The differences for most water-quality constituents is on the order of plus or minus 1 or 2 lowest rounding units. A lowest rounding unit is equivalent to the magnitude of the least significant figure reported for analytical results. The use of lowest rounding units avoids some of the difficulty in comparing differences between pairs of samples when concentrations span orders of magnitude and provides a measure of the practical significance of the effect of variability. Analysis of field-blank quality-control samples indicates that with the exception of chloride and silica, no systematic contamination of samples is apparent. Chloride contamination probably was the result of incomplete rinsing of the dilute cleaning solution from the outlet ports of the decaport sample splitter. Silica contamination seems to have been introduced by the blank water. Sampling and processing procedures for water year 1997 have been modified as a result of these analyses.

  9. Southern P indices, water quality data, and modeling results: a comparison

    USDA-ARS?s Scientific Manuscript database

    Phosphorus (P) indices in the south frequently produce different results for similar conditions. After collecting data from benchmark sites throughout the south (6 Arkansas, 1 Georgia, 2 Mississippi, 4 North Carolina, 4 Oklahoma, and 4 Texas site/treatment water quality and land treatment data sets...

  10. 76 FR 22868 - Certain Hot-Rolled Flat-Rolled Carbon-Quality Steel Products From Brazil: Final Results of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-25

    ...-Rolled Carbon-Quality Steel Products From Brazil: Final Results of Countervailing Duty Administrative... administrative review of the countervailing duty order on certain hot-rolled flat-rolled carbon- quality steel...-Quality Steel Products From Brazil: Preliminary Results of Countervailing Duty Administrative Review, 75...

  11. Geodetic results from ISAGEX data. [for obtaining center of mass coordinates for geodetic camera sites

    NASA Technical Reports Server (NTRS)

    Marsh, J. G.; Douglas, B. C.; Walls, D. M.

    1974-01-01

    Laser and camera data taken during the International Satellite Geodesy Experiment (ISAGEX) were used in dynamical solutions to obtain center-of-mass coordinates for the Astro-Soviet camera sites at Helwan, Egypt, and Oulan Bator, Mongolia, as well as the East European camera sites at Potsdam, German Democratic Republic, and Ondrejov, Czechoslovakia. The results are accurate to about 20m in each coordinate. The orbit of PEOLE (i=15) was also determined from ISAGEX data. Mean Kepler elements suitable for geodynamic investigations are presented.

  12. Measuring Service Quality in a Tertiary Institution.

    ERIC Educational Resources Information Center

    Soutar, Geoffrey; McNeil, Margaret

    1996-01-01

    Measures service quality from the viewpoint of customers (students at an Australian university), using the SERVQUAL model. Obtains evaluations of academic and administrative aspects of the educational service. Makes significant negative evaluations of administrative service quality (resulting from communication problems). Satisfaction with the…

  13. The Dutch Review Process for Evaluating the Quality of Psychological Tests: History, Procedure, and Results

    ERIC Educational Resources Information Center

    Evers, Arne; Sijtsma, Klaas; Lucassen, Wouter; Meijer, Rob R.

    2010-01-01

    This article describes the 2009 revision of the Dutch Rating System for Test Quality and presents the results of test ratings from almost 30 years. The rating system evaluates the quality of a test on seven criteria: theoretical basis, quality of the testing materials, comprehensiveness of the manual, norms, reliability, construct validity, and…

  14. Groundwater Quality Data for the Tahoe-Martis Study Unit, 2007: Results from the California GAMA Program

    USGS Publications Warehouse

    Fram, Miranda S.; Munday, Cathy; Belitz, Kenneth

    2009-01-01

    results obtained from these samples were used to evaluate the quality of the data for the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that data for the groundwater samples were not compromised by possible contamination during sample collection, handling or analysis. Differences between replicate samples were within acceptable ranges. Matrix spike recoveries were within acceptable ranges for most compounds. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, raw water typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to raw groundwater. However, to provide some context for the results, concentrations of constituents measured in the raw groundwater were compared with regulatory and nonregulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and the California Department of Public Health (CDPH), and with aesthetic and technical thresholds established by CDPH. Comparisons between data collected for this study and drinking-water thresholds are for illustrative purposes only and do not indicate of compliance or noncompliance with regulatory thresholds. The concentrations of most constituents detected in groundwater samples from the Tahoe-Martis wells were below drinking-water thresholds. Organic compounds (VOCs and pesticides) were detected in about 40 percent of the samples from grid wells, and most concentrations were less than 1/100th of regulatory and nonregulatory health-based thresholds, although the conentration of perchloroethene in one sample was above the USEPA maximum contaminant level (MCL-US). Concentrations of all trace elements and nutrients in samples from grid wells were below regulatory and nonregulatory health-based thresholds, with five exceptions. Concentra

  15. Groundwater-Quality Data in the Colorado River Study Unit, 2007: Results from the California GAMA Program

    USGS Publications Warehouse

    Goldrath, Dara A.; Wright, Michael T.; Belitz, Kenneth

    2010-01-01

    approximately 30 percent of the wells, and the results were used to evaluate the quality of the data obtained from the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a significant source of bias in the data. Differences between replicate samples were within acceptable ranges and matrix-spike recoveries were within acceptable ranges for most compounds. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, raw groundwater typically is treated, disinfected, or blended with other waters to maintain acceptable water quality. Regulatory thresholds apply to water that is served to the consumer, not to raw groundwater. However, to provide some context for the results, concentrations of constituents measured in the raw groundwater were compared to regulatory and nonregulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and the California Department of Public Health (CDPH) and to thresholds established for aesthetic concerns by CDPH. Comparisons between data collected for this study and drinking-water thresholds are for illustrative purposes only and do not indicate compliance or noncompliance with those thresholds. The concentrations of most constituents detected in groundwater samples were below drinking-water thresholds. Volatile organic compounds (VOC) were detected in approximately 35 percent of grid well samples; all concentrations were below health-based thresholds. Pesticides and pesticide degradates were detected in about 20 percent of all samples; detections were below health-based thresholds. No concentrations of constituents of special interest or nutrients were detected above health-based thresholds. Most of the major and minor ion constituents sampled do not have health-based thresholds; the exception is chloride. Concentrations of chloride, sulfate, and total dis

  16. TEPC measurements obtained on the Mir space station.

    PubMed

    Bottollier-Depois, J F; Siegrist, M; Petrov, V M; Shurshakov, V V; Bengin, V; Koslova, S B

    2002-10-01

    Measurements of the radiation environment inside the Mir space station were performed with a tissue equivalent proportional counter (TEPC) during the Antares mission in 1992, and over a long period following it. Interesting results concerning radiation measurements show (a) the South Atlantic Anomaly crossing, (b) the increase of radiation near the poles, and (c) the effects of solar particle events (the most important one occurring in early November 1992). This data also provides information about the dose and the quality factor of the radiation to which the cosmonauts were exposed during different missions. These data are compared with measurements obtained using a solid state detector. c2002 Elsevier Science Ltd. All rights reserved.

  17. Robustness and quality of precipitation and river flow data obtained through participatory monitoring and citizen scienc

    NASA Astrophysics Data System (ADS)

    Buytaert, W.; Ochoa-Tocachi, B. F.

    2016-12-01

    Apart for the most basic measurements of manual rain and staff gauges, hydrology and water resources are not an evident disciplines for the application of citizen science. High-resolution measurements require elaborate equipment, installation, and maintenance that is typically beyond the scope of non-scientists. Additionally, hydrological analysis has traditionally relied upon long time series of consistent accuracy and precision. Nevertheless, new opportunities for public participation in hydrological research are emerging, driven by increasingly affordable, robust, and more user-friendly technology. Here we analyse the results generated by participatory monitoring of river flow and precipitation in around 30 catchments in the tropical Andes. This monitoring network was set up through a collaborative effort between scientists, NGOs and local communities, with the intention to generate evidence about the impact of land-use change on streamflow. Monitoring was implemented using automatic but low-cost sensors operated and maintained by local users. Tipping bucket rain gauges are used for precipitation, and river flow is monitored with pressure transducers in combination with a V-notch weir to obtain a stable stage-discharge relation. Jointly, the sensors have now collected an equivalent of more than 30 years of data, with a measurement interval of typically 5 or 15 minutes. Analysing the data, we find that the observations themselves tend to be of a quality comparable to scientific observations. However, main issues are related to the continuity of the time series, as sensors eventually fail or run out of capacity in dataloggers or batteries in the most remote locations. Despite these shortcomings, the data have proven to be useful in characterizing land-use impacts well beyond what can be achieved with conventional data collection, thus filling long-standing gaps in local hydrological knowledge. Furthermore, we expect that the advent of new, more robust, resilient

  18. Results-driven approach to improving quality and productivity

    Treesearch

    John Dramm

    2000-01-01

    Quality control (QC) programs do not often realize their full potential. Elaborate and expensive QC programs can easily get side tracked by the process of building a program with promises of “Someday, this will all pay off.” Training employees in QC methods is no guarantee that quality will improve. Several documented cases show that such activity-centered efforts...

  19. Physicochemical properties of whole fruit plum powders obtained using different drying technologies.

    PubMed

    Michalska, Anna; Wojdyło, Aneta; Lech, Krzysztof; Łysiak, Grzegorz P; Figiel, Adam

    2016-09-15

    Physicochemical quality parameters of plum powders obtained by applying conventional drying methods and their combination devised to process plums were evaluated. The effect of freeze-drying (FD), vacuum drying (VD), convective drying (CD), microwave-vacuum drying (MVD) and combination of convective pre-drying and microwave finish-drying (CPD-MVFD) affected physical (bulk density, porosity, colour, solubility) and chemical (polyphenolic compounds determined by UPLC and antioxidant capacity by TEAC ABTS and FRAP methods) properties of plum powders. The MVD at 1.2 W g(-1) and a novel combination for plum powders production - CPD-MVFD at 70 °C/1.2 W g(-1) allowed the best preservation of phenolic compounds and increased the efficiency of production. Results obtained support the use of MVD and its combination for better quality of dried plum products. The study proved that the determination of the browning index and HMF level (formed via Maillard reaction) might be good tool for monitoring the thermal processing of plum powders. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Main results and experience obtained on Mir space station and experiment program for Russian segment of ISS.

    PubMed

    Utkin, V F; Lukjashchenko, V I; Borisov, V V; Suvorov, V V; Tsymbalyuk, M M

    2003-07-01

    This article presents main scientific and practical results obtained in course of scientific and applied research and experiments on Mir space station. Based on Mir experience, processes of research program formation for the Russian Segment of the ISS are briefly described. The major trends of activities planned in the frames of these programs as well as preliminary results of increment research programs implementation in the ISS' first missions are also presented. c2003 Elsevier Science Ltd. All rights reserved.

  1. Impacts of Industrial Wind Turbine Noise on Sleep Quality: Results From a Field Study of Rural Residents in Ontario, Canada.

    PubMed

    Lane, James D; Bigelow, Philip L; Majowicz, Shannon E; McColl, R Stephen

    2016-07-01

    The objectives of this study were to determine whether grid-connected industrial wind turbines (IWTs) are a risk factor for poor sleep quality, and if IWT noise is associated with sleep parameters in rural Ontarians. A daily sleep diary and actigraphy-derived measures of sleep were obtained from 12 participants from an IWT community and 10 participants from a comparison community with no wind power installations. The equivalent and maximum sound pressure levels within the bedroom were also assessed. No statistically significant differences were observed between IWT residents and non-IWT residents for any of the parameters measured in this study. Actigraphy and sleep diaries are feasible tools to understand the impact of IWTs on the quality of sleep for nearby residents. Further studies with larger sample sizes should be conducted to determine whether the lack of statistical significance observed here is a result of sample size, or reflects a true lack of association.

  2. 25 CFR 162.539 - Must I obtain a WEEL before obtaining a WSR lease?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... AND PERMITS Wind and Solar Resource Leases Wsr Leases § 162.539 Must I obtain a WEEL before obtaining... direct result of energy resource information gathered from a WEEL activity, obtaining a WEEL is not a...

  3. 25 CFR 162.539 - Must I obtain a WEEL before obtaining a WSR lease?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... AND PERMITS Wind and Solar Resource Leases Wsr Leases § 162.539 Must I obtain a WEEL before obtaining... direct result of energy resource information gathered from a WEEL activity, obtaining a WEEL is not a...

  4. Langley Wind Tunnel Data Quality Assurance-Check Standard Results

    NASA Technical Reports Server (NTRS)

    Hemsch, Michael J.; Grubb, John P.; Krieger, William B.; Cler, Daniel L.

    2000-01-01

    A framework for statistical evaluation, control and improvement of wind funnel measurement processes is presented The methodology is adapted from elements of the Measurement Assurance Plans developed by the National Bureau of Standards (now the National Institute of Standards and Technology) for standards and calibration laboratories. The present methodology is based on the notions of statistical quality control (SQC) together with check standard testing and a small number of customer repeat-run sets. The results of check standard and customer repeat-run -sets are analyzed using the statistical control chart-methods of Walter A. Shewhart long familiar to the SQC community. Control chart results are presented for. various measurement processes in five facilities at Langley Research Center. The processes include test section calibration, force and moment measurements with a balance, and instrument calibration.

  5. Quality planning in Construction Project

    NASA Astrophysics Data System (ADS)

    Othman, I.; Shafiq, Nasir; Nuruddin, M. F.

    2017-12-01

    The purpose of this paper is to investigate deeper on the factors that contribute to the effectiveness of quality planning, identifying the common problems encountered in quality planning, practices and ways for improvements in quality planning for construction projects. This paper involves data collected from construction company representatives across Malaysia that are obtained through semi-structured interviews as well as questionnaire distributions. Results shows that design of experiments (average index: 4.61), inspection (average index: 4.45) and quality audit as well as other methods (average index: 4.26) rank first, second and third most important factors respectively.

  6. Quality of Diabetes Care: The Challenges of an Increasing Epidemic in Mexico. Results from Two National Health Surveys (2006 and 2012)

    PubMed Central

    Flores-Hernández, Sergio; Saturno-Hernández, Pedro J.; Reyes-Morales, Hortensia; Barrientos-Gutiérrez, Tonatiuh; Villalpando, Salvador; Hernández-Ávila, Mauricio

    2015-01-01

    Background The quality of diabetes care remains suboptimal according to numerous studies assessing the achievement of quality indicators for diabetes care in various healthcare settings. We report about global and specific quality indicators for diabetes care and their association to glycemic control at the population level in two national health surveys in Mexico. Methods We conducted a cross-sectional analysis of the 2006 and 2012 National Health Surveys in Mexico. We examined quality of care for 2,965 and 4,483 adults (≥ 20 years) with diagnosed type 2 diabetes using fourteen simple and two composite indicators derived from self-reported information. In a subsample for both surveys, glycated hemoglobin (HbA1c) was measured at the time of the interview. We obtained survey weight-adjusted estimators using multiple regression models (logistic and linear) with combined data files, including survey year as covariate to assess change. Results Global quality of care in 2012 was 40.8%, with a relative improvement of 11.7% between 2006 and 2012. Detections of cardiovascular disease risk factors (dyslipidemia and hypertension) were the indicators with the highest improvement, while non-pharmaceutical treatment and diabetic foot exams showed minor changes. We found a significant association between the quality of the process of diabetes care and glycemic control (OR 2.53, 95% CI 1.63-3.94). Age more than 65 years old, the type of health subsystem, gender (males), and high socio-economic status were also significantly associated to glycemic control. Conclusions Quality diabetes care and glycemic control improved and are significantly associated. However, according to international standards, the current situation remains suboptimal. A more holistic approach is needed, with an emphasis on improving quality in outpatient care. PMID:26230991

  7. Quality Markers in Cardiology. Main Markers to Measure Quality of Results (Outcomes) and Quality Measures Related to Better Results in Clinical Practice (Performance Metrics). INCARDIO (Indicadores de Calidad en Unidades Asistenciales del Área del Corazón): A SEC/SECTCV Consensus Position Paper.

    PubMed

    López-Sendón, José; González-Juanatey, José Ramón; Pinto, Fausto; Cuenca Castillo, José; Badimón, Lina; Dalmau, Regina; González Torrecilla, Esteban; López-Mínguez, José Ramón; Maceira, Alicia M; Pascual-Figal, Domingo; Pomar Moya-Prats, José Luis; Sionis, Alessandro; Zamorano, José Luis

    2015-11-01

    Cardiology practice requires complex organization that impacts overall outcomes and may differ substantially among hospitals and communities. The aim of this consensus document is to define quality markers in cardiology, including markers to measure the quality of results (outcomes metrics) and quality measures related to better results in clinical practice (performance metrics). The document is mainly intended for the Spanish health care system and may serve as a basis for similar documents in other countries. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  8. Motion-base simulator results of advanced supersonic transport handling qualities with active controls

    NASA Technical Reports Server (NTRS)

    Feather, J. B.; Joshi, D. S.

    1981-01-01

    Handling qualities of the unaugmented advanced supersonic transport (AST) are deficient in the low-speed, landing approach regime. Consequently, improvement in handling with active control augmentation systems has been achieved using implicit model-following techniques. Extensive fixed-based simulator evaluations were used to validate these systems prior to tests with full motion and visual capabilities on a six-axis motion-base simulator (MBS). These tests compared the handling qualities of the unaugmented AST with several augmented configurations to ascertain the effectiveness of these systems. Cooper-Harper ratings, tracking errors, and control activity data from the MBS tests have been analyzed statistically. The results show the fully augmented AST handling qualities have been improved to an acceptable level.

  9. [Outcome quality in rehabilitation of children and adolescents: results of project aiming at the development of a quality assurance programme].

    PubMed

    Farin, E; Gustke, M; Widera, T; Matthies, S

    2012-06-01

    This study reports on the results of a project that was initiated by the German pension fund and the statutory health insurers and conducted in 2009 to 2010 with the goal of developing, arranging and testing instruments for quality assurance for the outcome (including patient satisfaction) in inpatient medical rehabilitation centres for children and adolescents. After a 6-month concept phase in which instruments were developed using value benefit analyses, expert consensus procedures, surveys of centres, and qualitative (cognitive interviews) and quantitative (psychometric tests) pre-studies, data were collected in 23 child and adolescent rehabilitation centres using the instruments that had been developed. The project was limited to the following 4 main diagnoses: obesity, bronchial asthma, atopic eczema, and hyperkinetic disorders as well as related disorders (ICD: F90-F94). Children and adolescents over the age of 12 years were interviewed themselves, for younger children, the parents were interviewed. It was decided to include 7 constructs that can be considered as indicators of the quality of the outcome or of patient satisfaction: generic and disease-specific quality of life, perceived change in health, body function parameters (e. g., blood pressure), disease-related self-management, satisfaction of the children/adolescents with rehabilitation, and parent satisfaction. With respect to quality of life, blood pressure, Munich fitness test and lung function parameters, low to medium effects were achieved; with respect to body mass index, SCORAD score and disease-related self-management, the effects were strong. The results can be summarised to the effect that rehabilitation generally achieves noticeable effects in the areas where the impairment is pronounced. In both the parent and the rehabilitation patient survey, there was a high level of satisfaction. The parents of rehab patients under the age of 12 years gave the centres an average assessment of 1.6 to 1

  10. Dynamic Analyses of Result Quality in Energy-Aware Approximate Programs

    NASA Astrophysics Data System (ADS)

    RIngenburg, Michael F.

    Energy efficiency is a key concern in the design of modern computer systems. One promising approach to energy-efficient computation, approximate computing, trades off output precision for energy efficiency. However, this tradeoff can have unexpected effects on computation quality. This thesis presents dynamic analysis tools to study, debug, and monitor the quality and energy efficiency of approximate computations. We propose three styles of tools: prototyping tools that allow developers to experiment with approximation in their applications, online tools that instrument code to determine the key sources of error, and online tools that monitor the quality of deployed applications in real time. Our prototyping tool is based on an extension to the functional language OCaml. We add approximation constructs to the language, an approximation simulator to the runtime, and profiling and auto-tuning tools for studying and experimenting with energy-quality tradeoffs. We also present two online debugging tools and three online monitoring tools. The first online tool identifies correlations between output quality and the total number of executions of, and errors in, individual approximate operations. The second tracks the number of approximate operations that flow into a particular value. Our online tools comprise three low-cost approaches to dynamic quality monitoring. They are designed to monitor quality in deployed applications without spending more energy than is saved by approximation. Online monitors can be used to perform real time adjustments to energy usage in order to meet specific quality goals. We present prototype implementations of all of these tools and describe their usage with several applications. Our prototyping, profiling, and autotuning tools allow us to experiment with approximation strategies and identify new strategies, our online tools succeed in providing new insights into the effects of approximation on output quality, and our monitors succeed in

  11. 40 CFR 63.11221 - Is there a minimum amount of monitoring data I must obtain?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...-control periods, and required monitoring system quality assurance or quality control activities including... monitoring system quality assurance or quality control activities in calculations used to report emissions or... monitoring data I must obtain? 63.11221 Section 63.11221 Protection of Environment ENVIRONMENTAL PROTECTION...

  12. 40 CFR 63.11221 - Is there a minimum amount of monitoring data I must obtain?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...-control periods, and required monitoring system quality assurance or quality control activities including... monitoring system quality assurance or quality control activities in calculations used to report emissions or... monitoring data I must obtain? 63.11221 Section 63.11221 Protection of Environment ENVIRONMENTAL PROTECTION...

  13. Continuous H/V spectral ratio analysis of ambient noise: a necessity to understand microzonation results obtained by mobile stations

    NASA Astrophysics Data System (ADS)

    Van Noten, Koen; Lecocq, Thomas

    2016-04-01

    Estimating the resonance frequency (f0) and amplification factor of unconsolidated sediments by H/V spectral ratio (HVSR) analysis of seismic ambient noise has been widely used since Nakamura's proposal in 1989. To measure f0 properly, Nakamura suggested to perform microzonation surveys at night when the artificial microtremor is small and does not fully disrupt the ambient seismic noise. As nightly fieldwork is not always a reasonable demand, we propose an alternative workflow of Nakamura's technique to improve the quality of HVSR results obtained by ambient noise measurements of mobile stations during the day. This new workflow includes the automated H/V calculation of continuous seismic data of a stationary or permanent station installed near the microzonation site for as long as the survey lasts in order to control the error in the HVSR analysis obtained by the mobile stations. In this presentation, we apply this workflow on one year of seismic data at two different case studies; i.e. a rural site with a shallow bedrock depth of 30 m and an urban site (Brussels, capital of Belgium, bedrock depth of 110 m) where human activity is continuous 24h/day. By means of an automated python script, the fundamental peak frequency and the H/V amplitude are automatically picked from H/V spectra that are calculated from 50% overlapping, 30 minute windows during the whole year. Afterwards, the f0 and amplitude picks are averaged per hour/per day for the whole year. In both case studies, the H/V amplitude and the fundamental frequencies range considerable, up to ˜15% difference between the daily and nightly measurements. As bedrock depth is known from boreholes at both sites, we concluded that the nightly picked f0 is the true one. Our results thus suggest that changes in the determined f0 and H/V amplitude are dominantly caused by the human behaviour which is stored in the ambient seismic noise (e.g. later onset of traffic in a weekend, quiet Sundays, differences between

  14. Assessing the quality of digital elevation models obtained from mini unmanned aerial vehicles for overland flow modelling in urban areas

    NASA Astrophysics Data System (ADS)

    Leitão, João P.; Moy de Vitry, Matthew; Scheidegger, Andreas; Rieckermann, Jörg

    2016-04-01

    Precise and detailed digital elevation models (DEMs) are essential to accurately predict overland flow in urban areas. Unfortunately, traditional sources of DEM, such as airplane light detection and ranging (lidar) DEMs and point and contour maps, remain a bottleneck for detailed and reliable overland flow models, because the resulting DEMs are too coarse to provide DEMs of sufficient detail to inform urban overland flows. Interestingly, technological developments of unmanned aerial vehicles (UAVs) suggest that they have matured enough to be a competitive alternative to satellites or airplanes. However, this has not been tested so far. In this study we therefore evaluated whether DEMs generated from UAV imagery are suitable for urban drainage overland flow modelling. Specifically, 14 UAV flights were conducted to assess the influence of four different flight parameters on the quality of generated DEMs: (i) flight altitude, (ii) image overlapping, (iii) camera pitch, and (iv) weather conditions. In addition, we compared the best-quality UAV DEM to a conventional lidar-based DEM. To evaluate both the quality of the UAV DEMs and the comparison to lidar-based DEMs, we performed regression analysis on several qualitative and quantitative metrics, such as elevation accuracy, quality of object representation (e.g. buildings, walls and trees) in the DEM, which were specifically tailored to assess overland flow modelling performance, using the flight parameters as explanatory variables. Our results suggested that, first, as expected, flight altitude influenced the DEM quality most, where lower flights produce better DEMs; in a similar fashion, overcast weather conditions are preferable, but weather conditions and other factors influence DEM quality much less. Second, we found that for urban overland flow modelling, the UAV DEMs performed competitively in comparison to a traditional lidar-based DEM. An important advantage of using UAVs to generate DEMs in urban areas is

  15. Effect of windowing on lithosphere elastic thickness estimates obtained via the coherence method: Results from northern South America

    NASA Astrophysics Data System (ADS)

    Ojeda, GermáN. Y.; Whitman, Dean

    2002-11-01

    The effective elastic thickness (Te) of the lithosphere is a parameter that describes the flexural strength of a plate. A method routinely used to quantify this parameter is to calculate the coherence between the two-dimensional gravity and topography spectra. Prior to spectra calculation, data grids must be "windowed" in order to avoid edge effects. We investigated the sensitivity of Te estimates obtained via the coherence method to mirroring, Hanning and multitaper windowing techniques on synthetic data as well as on data from northern South America. These analyses suggest that the choice of windowing technique plays an important role in Te estimates and may result in discrepancies of several kilometers depending on the selected windowing method. Te results from mirrored grids tend to be greater than those from Hanning smoothed or multitapered grids. Results obtained from mirrored grids are likely to be over-estimates. This effect may be due to artificial long wavelengths introduced into the data at the time of mirroring. Coherence estimates obtained from three subareas in northern South America indicate that the average effective elastic thickness is in the range of 29-30 km, according to Hanning and multitaper windowed data. Lateral variations across the study area could not be unequivocally determined from this study. We suggest that the resolution of the coherence method does not permit evaluation of small (i.e., ˜5 km), local Te variations. However, the efficiency and robustness of the coherence method in rendering continent-scale estimates of elastic thickness has been confirmed.

  16. Assessing the microbial quality of improved drinking water sources: results from the Dominican Republic.

    PubMed

    Baum, Rachel; Kayser, Georgia; Stauber, Christine; Sobsey, Mark

    2014-01-01

    Millennium Development Goal Target 7c (to halve between 1990 and 2015 the proportion of the global population without sustainable access to safe drinking water), was celebrated as achieved in 2012. However, new studies show that we may be prematurely celebrating. Access to safe drinking water may be overestimated if microbial water quality is considered. The objective of this study was to examine the relationship between microbial drinking water quality and drinking water source in the Puerto Plata region of the Dominican Republic. This study analyzed microbial drinking water quality data from 409 households in 33 communities. Results showed that 47% of improved drinking water sources were of high to very-high risk water quality, and therefore unsafe for drinking. This study provides evidence that the current estimate of safe water access may be overly optimistic, and microbial water quality data are needed to reliably assess the safety of drinking water.

  17. Quality of care for patients with diabetes mellitus type 2 in 'model practices' in Slovenia - first results.

    PubMed

    Petek, Davorina; Mlakar, Mitja

    2016-09-01

    A new organisation at the primary level, called model practices, introduces a 0.5 full-time equivalent nurse practitioner as a regular member of the team. Nurse practitioners are in charge of registers of chronic patients, and implement an active approach into medical care. Selected quality indicators define the quality of management. The majority of studies confirm the effectiveness of the extended team in the quality of care, which is similar or improved when compared to care performed by the physician alone. The aim of the study is to compare the quality of management of patients with diabetes mellitus type 2 before and after the introduction of model practices. A cohort retrospective study was based on medical records from three practices. Process quality indicators, such as regularity of HbA1c measurement, blood pressure measurement, foot exam, referral to eye exam, performance of yearly laboratory tests and HbA1c level before and after the introduction of model practices were compared. The final sample consisted of 132 patients, whose diabetes care was exclusively performed at the primary care level. The process of care has significantly improved after the delivery of model practices. The most outstanding is the increase of foot exam and HbA1c testing. We could not prove better glycaemic control (p>0.1). Nevertheless, the proposed benchmark for the suggested quality process and outcome indicators were mostly exceeded in this cohort. The introduction of a nurse into the team improves the process quality of care. Benchmarks for quality indicators are obtainable. Better outcomes of care need further confirmation.

  18. An Update on Phased Array Results Obtained on the GE Counter-Rotating Open Rotor Model

    NASA Technical Reports Server (NTRS)

    Podboy, Gary; Horvath, Csaba; Envia, Edmane

    2013-01-01

    Beamform maps have been generated from 1) simulated data generated by the LINPROP code and 2) actual experimental phased array data obtained on the GE Counter-rotating open rotor model. The beamform maps show that many of the tones in the experimental data come from their corresponding Mach radius. If the phased array points to the Mach radius associated with a tone then it is likely that the tone is a result of the loading and thickness noise on the blades. In this case, the phased array correctly points to where the noise is coming from and indicates the axial location of the loudest source in the image but not necessarily the correct vertical location. If the phased array does not point to the Mach radius associated with a tone then some mechanism other than loading and thickness noise may control the amplitude of the tone. In this case, the phased array may or may not point to the actual source. If the source is not rotating it is likely that the phased array points to the source. If the source is rotating it is likely that the phased array indicates the axial location of the loudest source but not necessarily the correct vertical location. These results indicate that you have to be careful in how you interpret phased array data obtained on an open rotor since they may show the tones coming from a location other than the source location. With a subsonic tip speed open rotor the tones can come form locations outboard of the blade tips. This has implications regarding noise shielding.

  19. Feasibility and quality of nonmydriatic fundus photography in children

    PubMed Central

    Toffoli, Daniela; Bruce, Beau B.; Lamirel, Cédric; Henderson, Amanda D.; Newman, Nancy J.; Biousse, Valérie

    2011-01-01

    Purpose Ocular funduscopic examination is difficult in young children and is rarely attempted by nonophthalmologists. Our objective was to determine the feasibility of reliably obtaining high-quality nonmydriatic fundus photographs in children. Methods Nonmydriatic fundus photographs were obtained in both eyes of children seen in a pediatric ophthalmology clinic. Ease of fundus photography was recorded on a 10-point Likert scale (10 = very easy). Quality was graded from 1 to 5 (1, inadequate for any diagnostic purpose; 2, unable to exclude all emergent findings; 3, only able to exclude emergent findings; 4, not ideal, but still able to exclude subtle findings; and 5, ideal quality). The primary outcome measure was image quality by age. Results A total of 878 photographs of 212 children (median age, 6 years; range,1-18 years) were included. Photographs of at least one eye were obtained in 190 children (89.6%) and in both eyes in 181 (85.3%). Median rating for ease of photography was 7. Photographs of some clinical value (grade ≥2) were obtained in 33% of children <3 years and 95% >3 years. High-quality photographs (grade 4 or 5) were obtained in both eyes in 7% of children <3 years, 57% of children ≥3 to <7 years, 85% of children ≥7 to <9 years, and 65% of children ≥9 years. The youngest patient with high-quality photographs in both eyes was 22 months. Conclusions Nonmydriatic fundus photographs of adequate quality can be obtained in children over age 3 and in some children as young as 22 months. PMID:22153402

  20. Single-Site, Results-Level Evaluation of Quality Awareness Training.

    ERIC Educational Resources Information Center

    Murray, Brian; Raffaele, Gary C.

    1997-01-01

    An interrupted time-series design pooling 6 12-year series evaluated the long-term effects of a quality training intervention in a factory. Training positively affected quality of goods and dollar utility. Production process was an important contextual factor in assessing the effect size of the intervention. (SK)

  1. Different Roles and Different Results: How Activity Orientations Correspond to Relationship Quality and Student Outcomes in School-Based Mentoring

    ERIC Educational Resources Information Center

    Keller, Thomas E.; Pryce, Julia M.

    2012-01-01

    This prospective, mixed-methods study investigated how the nature of joint activities between volunteer mentors and student mentees corresponded to relationship quality and youth outcomes. Focusing on relationships in school-based mentoring programs in low-income urban elementary schools, data were obtained through pre-post assessments,…

  2. A novel, fuzzy-based air quality index (FAQI) for air quality assessment

    NASA Astrophysics Data System (ADS)

    Sowlat, Mohammad Hossein; Gharibi, Hamed; Yunesian, Masud; Tayefeh Mahmoudi, Maryam; Lotfi, Saeedeh

    2011-04-01

    The ever increasing level of air pollution in most areas of the world has led to development of a variety of air quality indices for estimation of health effects of air pollution, though the indices have their own limitations such as high levels of subjectivity. Present study, therefore, aimed at developing a novel, fuzzy-based air quality index (FAQI ) to handle such limitations. The index developed by present study is based on fuzzy logic that is considered as one of the most common computational methods of artificial intelligence. In addition to criteria air pollutants (i.e. CO, SO 2, PM 10, O 3, NO 2), benzene, toluene, ethylbenzene, xylene, and 1,3-butadiene were also taken into account in the index proposed, because of their considerable health effects. Different weighting factors were then assigned to each pollutant according to its priority. Trapezoidal membership functions were employed for classifications and the final index consisted of 72 inference rules. To assess the performance of the index, a case study was carried out employing air quality data at five different sampling stations in Tehran, Iran, from January 2008 to December 2009, results of which were then compared to the results obtained from USEPA air quality index (AQI). According to the results from present study, fuzzy-based air quality index is a comprehensive tool for classification of air quality and tends to produce accurate results. Therefore, it can be considered useful, reliable, and suitable for consideration by local authorities in air quality assessment and management schemes. Fuzzy-based air quality index (FAQI).

  3. Assessing the Microbial Quality of Improved Drinking Water Sources: Results from the Dominican Republic

    PubMed Central

    Baum, Rachel; Kayser, Georgia; Stauber, Christine; Sobsey, Mark

    2014-01-01

    Millennium Development Goal Target 7c (to halve between 1990 and 2015 the proportion of the global population without sustainable access to safe drinking water), was celebrated as achieved in 2012. However, new studies show that we may be prematurely celebrating. Access to safe drinking water may be overestimated if microbial water quality is considered. The objective of this study was to examine the relationship between microbial drinking water quality and drinking water source in the Puerto Plata region of the Dominican Republic. This study analyzed microbial drinking water quality data from 409 households in 33 communities. Results showed that 47% of improved drinking water sources were of high to very-high risk water quality, and therefore unsafe for drinking. This study provides evidence that the current estimate of safe water access may be overly optimistic, and microbial water quality data are needed to reliably assess the safety of drinking water. PMID:24218411

  4. Colostomy irrigation: results of 25 cases with particular reference to quality of life.

    PubMed

    Karadağ, Ayişe; Menteş, B Bülent; Ayaz, Sultan

    2005-04-01

    The aim of this study was to document our results with colostomy irrigation with particular emphasis on the possible contribution of irrigation on quality of life. Colostomy irrigation is a useful method of achieving faecal continence in selected conditions, and may improve quality of life. When successful, irrigation offers a regular, predictable elimination pattern and only a small covering is needed for security between irrigations. The digestive disease quality of life questionnaire-15 (DDQ-15) and Short Form-36 were used to analyse quality of life before and 12 months after stomatherapy in a series of 25 irrigating patients with permanent end colostomies. During the same time period, 10 similar patients with left-end colostomies who also received counselling but did not consent to colostomy irrigation were also analysed for comparison. Colostomy irrigation was found to be effective for achieving faecal continence in selected patients with end colostomies with no complications or significant side-effects, The digestive disease quality of life questionnaire-15 score improved significantly in both groups after stomatherapy (P < 0.0001 and P = 0.009 in the irrigating and non-irrigating groups respectively). The poststomatherapy digestive disease quality of life questionnaire-15 score of the irrigating group was also significantly higher than that of the non-irrigating group (P = 0.039). Although none of the poststomatherapy item scales of Short Form-36 differed significantly between the two groups, stomatherapy with CI resulted in significant improvements in role limitation due to physical problems, social functioning, role limitation due to emotional problems, general mental health, vitality and bodily pain (P < 0.05 for all comparisons). On the contrary, the non-irrigating patient group showed significant improvements only in social functioning and general mental health. Our findings suggest that colostomy irrigation can be a useful method of achieving faecal

  5. Initial poor quality of life and new onset of dyspepsia: results from a longitudinal 10‐year follow‐up study

    PubMed Central

    Ford, Alexander C; Forman, David; Bailey, Alastair G; Axon, Anthony T R; Moayyedi, Paul

    2007-01-01

    Background Numerous studies examining the prevalence and natural history of dyspepsia in the general population have been conducted. However, few have reported the effect of quality of life on the development of dyspepsia. A 10‐year longitudinal follow‐up study examining the effect of quality of life on subsequent dyspepsia was performed. Methods Individuals originally enrolled in a population‐screening programme for Helicobacter pylori were contacted through a validated postal dyspepsia questionnaire. Baseline demographic data, quality of life at original study entry, and dyspepsia and irritable bowel syndrome (IBS) symptom data were already on file. Consent to examine primary‐care records was sought, and data regarding non‐steroidal anti‐inflammatory drugs (NSAID) and aspirin use were obtained from these. Results Of 8407 individuals originally involved, 3912 (46.5%) provided symptom data at baseline and 10‐year follow‐up. Of 2550 (65%) individuals asymptomatic at study entry, 717 (28%) developed new‐onset dyspepsia at 10 years, an incidence of 2.8% per year. After multivariate logistic regression, lower quality of life at study entry (OR 2.63; 99% CI 1.86 to 3.71), higher body mass index (OR per unit 1.05; 99% CI 1.02 to 1.08), presence of IBS at study entry (OR 3.1; 99% CI 1.51 to 6.37) and use of NSAIDs and/or aspirin (OR 1.32; 99% CI 0.99 to 1.75) were significant risk factors for new‐onset dyspepsia. Conclusions The incidence of new‐onset dyspepsia was almost 3% per year. Low quality of life at baseline exerted a strong effect on the likelihood of developing dyspepsia at 10 years. PMID:16908511

  6. The economic impact of poor sample quality in clinical chemistry laboratories: results from a global survey.

    PubMed

    Erdal, Erik P; Mitra, Debanjali; Khangulov, Victor S; Church, Stephen; Plokhoy, Elizabeth

    2017-03-01

    Background Despite advances in clinical chemistry testing, poor blood sample quality continues to impact laboratory operations and the quality of results. While previous studies have identified the preanalytical causes of lower sample quality, few studies have examined the economic impact of poor sample quality on the laboratory. Specifically, the costs associated with workarounds related to fibrin and gel contaminants remain largely unexplored. Methods A quantitative survey of clinical chemistry laboratory stakeholders across 10 international regions, including countries in North America, Europe and Oceania, was conducted to examine current blood sample testing practices, sample quality issues and practices to remediate poor sample quality. Survey data were used to estimate costs incurred by laboratories to mitigate sample quality issues. Results Responses from 164 participants were included in the analysis, which was focused on three specific issues: fibrin strands, fibrin masses and gel globules. Fibrin strands were the most commonly reported issue, with an overall incidence rate of ∼3%. Further, 65% of respondents indicated that these issues contribute to analyzer probe clogging, and the majority of laboratories had visual inspection and manual remediation practices in place to address fibrin- and gel-related quality problems (55% and 70%, respectively). Probe maintenance/replacement, visual inspection and manual remediation were estimated to carry significant costs for the laboratories surveyed. Annual cost associated with lower sample quality and remediation related to fibrin and/or gel globules for an average US laboratory was estimated to be $100,247. Conclusions Measures to improve blood sample quality present an important step towards improved laboratory operations.

  7. [Quality assurance in therapy of chronic pain. Results obtained by a taskforce of the German Section of the Association for the Study of Pain on psychological assessment of chronic pain.].

    PubMed

    Denecke, H; Glier, B; Klinger, R; Nilges, P; Redegeld, M; Weiß, L; Kröner-Herwig, B

    1995-01-01

    This is the first in a series of publications presenting the results of a taskforce on quality assurance in psychological assessment of chronic pain. The initiative was motivated by the increasing and confusing variety of newly developed German instruments and/or translations of Anglo-American instruments. Our main work was therefore concentrated on the collection of existing German assessment instruments, on summarizing the essentials in a documentary sheet, and on examining their objectivity, reliability, validity, clinical relevance, economy and degree of empirical foundation. For each diagnostic domain we thus elaborated specific differential recommendations for those working in psychological pain research and clinical practice, in an attempt to devise criteria enabling them to choose the optimal instrument or test battery for their needs and conditions.

  8. Quality of life in chemical warfare survivors with ophthalmologic injuries: the first results form Iran Chemical Warfare Victims Health Assessment Study

    PubMed Central

    Mousavi, Batool; Soroush, Mohammad Reza; Montazeri, Ali

    2009-01-01

    Background Iraq used chemical weapons extensively against the Iranians during the Iran-Iraq war (1980–1988). The aim of this study was to assess the health related quality of life (HRQOL) in people who had ophthalmologic complications due to the sulfur mustard gas exposure during the war. Methods The Veterans and Martyrs Affair Foundation (VMAF) database indicated that there were 196 patients with severe ophthalmologic complications due to chemical weapons exposure. Of these, those who gave consent (n = 147) entered into the study. Quality of life was measured using the 36-item Short Form Health Survey (SF-36) and scores were compared to those of the general public. In addition logistic regression analysis was performed to indicate variables that contribute to physical and mental health related quality of life. Results The mean age of the patients was 44.8 (SD = 8.7) ranging from 21 to 75 years. About one-third of the cases (n= 50) reported exposure to chemical weapons more than once. The mean exposure duration to sulfur mustard gas was 21.6 years (SD = 1.2). The lowest scores on the SF-36 subscales were found to be: the role physical and the general health. Quality of life in chemical warfare victims who had ophthalmologic problems was significantly lower than the general public (P < 0.001). The results obtained from logistic regression analysis indicated that those who did not participate in sport activities suffer from a poorer physical health (OR = 2.93, 95% CI = 1.36 to 6.30, P = 0.006). The analysis also showed that poor mental health was associated with longer time since exposure (OR = 1.58, 95% CI = 1.04 to 2.39, P = 0.03) and lower education (OR = 3.03, 95% CI = 1.21 to 7.56, P = 0.01). Conclusion The study findings suggest that chemical warfare victims with ophthalmologic complications suffer from poor health related quality of life. It seems that the need for provision of health and support for this population is urgent. In addition, further research

  9. A comparative study of Sephadex, glass wool and Percoll separation techniques on sperm quality and IVF results for cryopreserved bovine semen.

    PubMed

    Lee, Hae-Lee; Kim, Sue-Hee; Ji, Dong-Beom; Kim, Yong-Jun

    2009-09-01

    The aim of this study was to compare the effects of spermatozoa separation techniques on sperm quality and in-vitro fertilization (IVF) results for cryopreserved bovine semen. Sephadex, glass wool and Percoll gradient separation techniques were used for sperm separation and sperm motility, morphology and membrane integrity were evaluated before and after separation. Also, cleavage and blastocyst developmental rate were investigated after IVF with sperm recovered by each separation technique. The motility of samples obtained by the three separation techniques were greater compared to the control samples (p < 0.05). The percentage of spermatozoa with intact plasma-membrane integrity, identified by 6-carboxyfluoresceindiacetate/ propidium iodide fluorescent staining and the hypo-osmotic swelling test, was highest in the glass wool filtration samples (p < 0.05). The cleavage and blastocyst rate of total oocytes produced from glass wool filtration samples were also higher than the control and Sephadex filtration samples (p < 0.05), but were not significantly different from Percoll separation samples. However, a significantly greater number of cleaved embryos produced by glass wool filtration developed to blastocyst stage than those produced by Percoll separation (p < 0.05). These results indicate that spermatozoa with good quality can be achieved by these three separation techniques and can be used for bovine IVF. In particular, it suggests that glass wool filtration would be the most effective method of the three for improving sperm quality and embryo production for cryopreserved bovine spermatozoa.

  10. High-quality compressive ghost imaging

    NASA Astrophysics Data System (ADS)

    Huang, Heyan; Zhou, Cheng; Tian, Tian; Liu, Dongqi; Song, Lijun

    2018-04-01

    We propose a high-quality compressive ghost imaging method based on projected Landweber regularization and guided filter, which effectively reduce the undersampling noise and improve the resolution. In our scheme, the original object is reconstructed by decomposing of regularization and denoising steps instead of solving a minimization problem in compressive reconstruction process. The simulation and experimental results show that our method can obtain high ghost imaging quality in terms of PSNR and visual observation.

  11. Comparison of Theoretical Stresses and Deflections of Multicell Wings with Experimental Results Obtained from Plastic Models

    NASA Technical Reports Server (NTRS)

    Zender, George W

    1956-01-01

    The experimental deflections and stresses of six plastic multicell-wing models of unswept, delta, and swept plan form are presented and compared with previously published theoretical results obtained by the electrical analog method. The comparisons indicate that the theory is reliable except for the evaluation of stresses in the vicinity of the leading edge of delta wings and the leading and trailing edges of swept wings. The stresses in these regions are questionable, apparently because of simplifications employed in idealizing the actual structure for theoretical purposes and because of local effects of concentrated loads.

  12. From Results to Action - Implementing an Indoor Air Quality Pilot Project

    NASA Astrophysics Data System (ADS)

    Collier, A. M.; Ware, G. E.; Iwasaki, P. G.; Billingsley, L. R.; Main, D.; Hannigan, M.; Pfotenhauer, D.

    2016-12-01

    One of the key differences between community-based participatory research (CBPR) and more conventional scientific research is the expectation that a project does not end with finalized results, but rather with taking action based on those results. Using an indoor air quality pilot project as an example, we will discuss how the consideration of potential actions and applications for the project findings should be integrated into planning throughout the life of a project. We will also share general reflections on effective CBPR from the perspective of both science and community partners on the project. In 2015, Taking Neighborhood Health to Heart (TNH2H), a community-based organization in Northeast Denver, researchers from the University of Colorado, Boulder, and AGU's Thriving Earth Exchange partnered to conduct a pilot project investigating indoor air quality in a Denver community. This partnership formed in response to community concerns about potential environmental contamination from dry cleaning operations, specifically through spills of the compound perchloroethylene. The exploration of the presence of radon, another indoor air quality concern common across the state of Colorado, was also added to the project. Using an iterative process, the team designed a sampling plan, selected a target location, and recruited homes and residents to participate in the pilot project. Radon and perchloroethylene data were then collected in 15 homes. Following data collection, results were first shared with project participants, after which de-identified data were shared with the members of TNH2H. Together TNH2H and researchers then developed strategies for public dissemination of the project findings. While we did not find levels of percholorethylene above the `action level' in any of the participating homes; however, we did find more frequent occurrences of radon levels above the `action level' than we had anticipated. For example, 80% of the homes in our study had radon

  13. Groundwater-Quality Data in the South Coast Interior Basins Study Unit, 2008: Results from the California GAMA Program

    USGS Publications Warehouse

    Mathany, Timothy M.; Kulongoski, Justin T.; Ray, Mary C.; Belitz, Kenneth

    2009-01-01

    ], and radioactive constituents [gross alpha and gross beta radioactivity and radon-222]. Naturally occurring isotopes [stable isotopes of hydrogen, oxygen, and carbon, and activities of tritium and carbon-14] and dissolved noble gases also were measured to help identify the sources and ages of the sampled groundwater. In total, 288 constituents and water-quality indicators (field parameters) were investigated. Three types of quality-control samples (blanks, replicates, and matrix spikes) each were collected at approximately 4-11 percent of the wells, and the results for these samples were used to evaluate the quality of the data for the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a significant source of bias in the data obtained from the groundwater samples. Differences between replicate samples generally were less than 10 percent relative standard deviation, indicating acceptable analytical reproducibility. Matrix spike recoveries were within the acceptable range (70 to 130 percent) for most compounds. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, untreated groundwater typically is treated, disinfected, and/or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to untreated groundwater. However, to provide some context for the results, concentrations of constituents measured in the untreated groundwater were compared with regulatory and nonregulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH), and to nonregulatory thresholds established for aesthetic and technical concerns by CDPH. Comparisons between data collected for this study and thresholds for drinking water are for illustrative purposes only, and are not indicative of complia

  14. Assessment of national dosimetry quality audits results for teletherapy machines from 1989 to 2015.

    PubMed

    Muhammad, Wazir; Ullah, Asad; Mahmood, Khalid; Matiullah

    2016-01-01

    The purpose of this study was to ensure accuracy in radiation dose delivery, external dosimetry quality audit has an equal importance with routine dosimetry performed at clinics. To do so, dosimetry quality audit was organized by the Secondary Standard Dosimetry Laboratory (SSDL) of Pakistan Institute of Nuclear Science and Technology (PINSTECH) at the national level to investigate and minimize uncertainties involved in the measurement of absorbed dose, and to improve the accuracy of dose measurement at different radiotherapy hospitals. A total of 181 dosimetry quality audits (i.e., 102 of Co-60 and 79 of linear accelerators) for teletherapy units installed at 22 different sites were performed from 1989 to 2015. The percent deviation between users’ calculated/stated dose and evaluated dose (in the result of on-site dosimetry visits) were calculated and the results were analyzed with respect to the limits of ± 2.5% (ICRU "optimal model") ± 3.0% (IAEA on-site dosimetry visits limit) and ± 5.0% (ICRU minimal or "lowest acceptable" model). The results showed that out of 181 total on-site dosimetry visits, 20.44%, 16.02%, and 4.42% were out of acceptable limits of ± 2.5% ± 3.0%, and ± 5.0%, respectively. The importance of a proper ongoing quality assurance program, recommendations of the followed protocols, and properly calibrated thermometers, pressure gauges, and humidity meters at radiotherapy hospitals are essential in maintaining consistency and uniformity of absorbed dose measurements for precision in dose delivery.

  15. [Method for the quality assessment of data collection processes in epidemiological studies].

    PubMed

    Schöne, G; Damerow, S; Hölling, H; Houben, R; Gabrys, L

    2017-10-01

    For a quantitative evaluation of primary data collection processes in epidemiological surveys based on accompaniments and observations (in the field), there is no description of test criteria and methodologies in relevant literature and thus no known application in practice. Therefore, methods need to be developed and existing procedures adapted. The aim was to identify quality-relevant developments within quality dimensions by means of inspection points (quality indicators) during the process of data collection. As a result we seek to implement and establish a methodology for the assessment of overall survey quality supplementary to standardized data analyses. Monitors detect deviations from standard primary data collection during site visits by applying standardized checklists. Quantitative results - overall and for each dimension - are obtained by numerical calculation of quality indicators. Score results are categorized and color coded. This visual prioritization indicates necessity for intervention. The results obtained give clues regarding the current quality of data collection. This allows for the identification of such sections where interventions for quality improvement are needed. In addition, process quality development can be shown over time on an intercomparable basis. This methodology for the evaluation of data collection quality can identify deviations from norms, focalize quality analyses and help trace causes for significant deviations.

  16. Quality in-training initiative--a solution to the need for education in quality improvement: results from a survey of program directors.

    PubMed

    Kelz, Rachel R; Sellers, Morgan M; Reinke, Caroline E; Medbery, Rachel L; Morris, Jon; Ko, Clifford

    2013-12-01

    The Next Accreditation System and the Clinical Learning Environment Review Program will emphasize practice-based learning and improvement and systems-based practice. We present the results of a survey of general surgery program directors to characterize the current state of quality improvement in graduate surgical education and introduce the Quality In-Training Initiative (QITI). In 2012, a 20-item survey was distributed to 118 surgical residency program directors from ACS NSQIP-affiliated hospitals. The survey content was developed in collaboration with the QITI to identify program director opinions regarding education in practice-based learning and improvement and systems-based practice, to investigate the status of quality improvement education in their respective programs, and to quantify the extent of resident participation in quality improvement. There was a 57% response rate. Eighty-five percent of program directors (n = 57) reported that education in quality improvement is essential to future professional work in the field of surgery. Only 28% (n = 18) of programs reported that at least 50% of their residents track and analyze their patient outcomes, compare them with norms/benchmarks/published standards, and identify opportunities to make practice improvements. Program directors recognize the importance of quality improvement efforts in surgical practice. Subpar participation in basic practice-based learning and improvement activities at the resident level reflects the need for support of these educational goals. The QITI will facilitate programmatic compliance with goals for quality improvement education. Copyright © 2013 American College of Surgeons. All rights reserved.

  17. Health-related quality of life in epilepsy: findings obtained with a new Italian instrument.

    PubMed

    Piazzini, Ada; Beghi, Ettore; Turner, Katherine; Ferraroni, Monica

    2008-07-01

    The aim of the present study was to evaluate the Epi-QoL, a new Italian-specific measure of health-related quality of life (HRQOL) for adults with epilepsy; the clinical variables that affected the HRQOL score were also assessed. The Epi-QoL is a 46-item self-administered questionnaire focusing on six domains: Physical Functioning, Cognitive Functioning, Emotional Well-Being, Social Functioning, Seizure Worry, and Medication Effects. Eight hundred fifteen patients recruited from 24 secondary and tertiary Italian centers for the care of epilepsy were assessed. The results supported the reliability and validity of the Epi-QoL as a measure of HRQOL. The variables that significantly affected HRQOL scores were: geographic area, gender, seizure frequency, prognostic categories, number of medications, comorbidity, presence of cognitive impairment, psychiatric disturbances, and disability. We believe that a new specific questionnaire for the evaluation of HRQOL in Italy can contribute much to the understanding of the influence of epilepsy on patients' lives.

  18. Microbiological quality of frozen cauliflower, corn, and peas obtained at retail markets.

    PubMed Central

    Barnard, R J; Duran, A P; Swartzentruber, A; Schwab, A H; Wentz, B A; Read, R B

    1982-01-01

    The microbiological quality of blanched frozen cauliflower, cut corn, and peas at the retail level was determined. At 35 degrees C, mean aerobic plate count (APC) values for cauliflower, corn, and peas, respectively, were 30,000, 6,100, and 4,700 per g; at 30 degrees C, the mean APC values were 45,000, 8,500, and 6,800 per g, respectively. Geometric means for coliform, Escherichia coli, and Staphylococcus aureus counts for all three vegetables were less than 10 per g. PMID:6751226

  19. Quality of claims, references and the presentation of risk results in medical journal advertising: a comparative study in Australia, Malaysia and the United States.

    PubMed

    Othman, Noordin; Vitry, Agnes I; Roughead, Elizabeth E

    2010-05-29

    Journal advertising is used by pharmaceutical companies to disseminate medicine information to doctors. The quality of claims, references and the presentation of risk results in Australia and the US has been questioned in several studies. No recent evidence is available on the quality of claims, references and the presentation of risk results in journal advertising in Australia and the US and no Malaysian data have been published. The aim of this study was to compare the quality of claims, references and the presentation of risk results in journal advertising in these three countries. A consecutive sample of 85 unique advertisements from each country was selected from journal advertising published between January 2004 to December 2006. Claims, references and the presentation of risk results in medical journal advertising were compared between the three countries. Less than one-third of the claims were unambiguous claims (Australia, 30%, Malaysia 17%, US, 23%). In Malaysia significantly less unambiguous claims were provided than in Australia and the US (P < 0.001). However, the unambiguous claims were supported by more references than other claims (80%). Most evidence was obtained from at least one randomized controlled trial, a systematic review or meta-analysis (Australia, 84%, Malaysia, 81%, US, 76%) with journal articles being the most commonly cited references in all countries. Data on file were significantly more likely to be cited in the US (17%) than in Australia (2%) and Malaysia (4%) (P < 0.001). Advertisements that provided quantitative information reported risk results exclusively as a relative risk reduction. The majority of claims were vague suggesting poor quality of claims in journal advertising in these three countries. Evidence from a randomized controlled trial, systematic review or meta- analysis was commonly cited to support claims. However, the more frequent use of data that have not been published and independently reviewed in the US compared

  20. A Pragmatic Smoothing Method for Improving the Quality of the Results in Atomic Spectroscopy

    NASA Astrophysics Data System (ADS)

    Bennun, Leonardo

    2017-07-01

    A new smoothing method for the improvement on the identification and quantification of spectral functions based on the previous knowledge of the signals that are expected to be quantified, is presented. These signals are used as weighted coefficients in the smoothing algorithm. This smoothing method was conceived to be applied in atomic and nuclear spectroscopies preferably to these techniques where net counts are proportional to acquisition time, such as particle induced X-ray emission (PIXE) and other X-ray fluorescence spectroscopic methods, etc. This algorithm, when properly applied, does not distort the form nor the intensity of the signal, so it is well suited for all kind of spectroscopic techniques. This method is extremely effective at reducing high-frequency noise in the signal much more efficient than a single rectangular smooth of the same width. As all of smoothing techniques, the proposed method improves the precision of the results, but in this case we found also a systematic improvement on the accuracy of the results. We still have to evaluate the improvement on the quality of the results when this method is applied over real experimental results. We expect better characterization of the net area quantification of the peaks, and smaller Detection and Quantification Limits. We have applied this method to signals that obey Poisson statistics, but with the same ideas and criteria, it could be applied to time series. In a general case, when this algorithm is applied over experimental results, also it would be required that the sought characteristic functions, required for this weighted smoothing method, should be obtained from a system with strong stability. If the sought signals are not perfectly clean, this method should be carefully applied

  1. Evaluation of a statistics-based Ames mutagenicity QSAR model and interpretation of the results obtained.

    PubMed

    Barber, Chris; Cayley, Alex; Hanser, Thierry; Harding, Alex; Heghes, Crina; Vessey, Jonathan D; Werner, Stephane; Weiner, Sandy K; Wichard, Joerg; Giddings, Amanda; Glowienke, Susanne; Parenty, Alexis; Brigo, Alessandro; Spirkl, Hans-Peter; Amberg, Alexander; Kemper, Ray; Greene, Nigel

    2016-04-01

    The relative wealth of bacterial mutagenicity data available in the public literature means that in silico quantitative/qualitative structure activity relationship (QSAR) systems can readily be built for this endpoint. A good means of evaluating the performance of such systems is to use private unpublished data sets, which generally represent a more distinct chemical space than publicly available test sets and, as a result, provide a greater challenge to the model. However, raw performance metrics should not be the only factor considered when judging this type of software since expert interpretation of the results obtained may allow for further improvements in predictivity. Enough information should be provided by a QSAR to allow the user to make general, scientifically-based arguments in order to assess and overrule predictions when necessary. With all this in mind, we sought to validate the performance of the statistics-based in vitro bacterial mutagenicity prediction system Sarah Nexus (version 1.1) against private test data sets supplied by nine different pharmaceutical companies. The results of these evaluations were then analysed in order to identify findings presented by the model which would be useful for the user to take into consideration when interpreting the results and making their final decision about the mutagenic potential of a given compound. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. The relative ease of obtaining a dermatologic appointment in Boston: how methods drive results.

    PubMed

    Weingold, David Howard; Lack, Michael Dweight; Yanowitz, Karen Leslie

    2009-06-01

    Recent reports have indicated long wait times for dermatologic appointments even for changing moles. Our objective was to determine the wait time for a person willing to make multiple calls and accept an appointment from any dermatologist at any satellite location for a changing mole from a dermatologist who advertised in a Boston, MA, telephone book. We telephoned each practice listed in a Boston, MA, telephone book. Patients making one call to each dermatologic practice on average obtained an appointment in 18 days. Patients calling two practices were offered an appointment on average in 7 days. Patients calling 3 practices were also offered an appointment in 1 week. We only telephoned practices listed in a Boston, MA, telephone book and we only surveyed one urban area. These results suggest that a reasonable concerned patient who was willing to make multiple calls to different providers in Boston, MA, can be seen in a timely fashion.

  3. First clinicial results on the feasibility, quality and reproducibility of aberrometry-based intraoperative refraction during cataract surgery.

    PubMed

    Huelle, Jan O; Katz, Toam; Druchkiv, Vasyl; Pahlitzsch, Milena; Steinberg, Johannes; Richard, Gisbert; Linke, Stephan J

    2014-11-01

    To provide the first clinical data in determining the feasibility, quality and precision of intraoperative wavefront aberrometry (IWA)-based refraction in patients with cataract. IWA refraction was recorded at 7 defined measurement points during standardised cataract surgery in 74 eyes of 74 consecutive patients (mean age 69±11.3 years). Precision and measurement quality was evaluated by the 'limits of agreement' approach, regression analysis, correlation analysis, Analysis of variance (ANOVA) and ORs for predicting measurement failure. Wavefront map (WFM) quality was objectivised and compared with the Pentacam Nuclear Staging analysis. Out of 814 IWA measurement attempts, 462 WFMs could be obtained. The most successful readings (n=63) were achieved in aphakia with viscoelastic. The highest (50.63%, SD 20.23) and lowest (29.19%, SD 13.94) quality of WFMs across all measurement points were found after clear corneal incision and in pseudophakia with viscoelastic, respectively. High consistency across repeated measures were found for mean spherical equivalent (SE) differences in aphakia with -0.01D and pseudophakia with -0.01D, but ranges were high (limits of agreement +0.69 D and -0.72 D; +1.53 D and -1.54 D, respectively). With increasing WFM quality, higher precision in measurements was observed. This is the first report addressing quality and reproducibility of WA in a large sample. IWA refraction in aphakia, for instance, appears to be reliable once stable and pressurised anterior chamber conditions are achieved. More efforts are required to improve the precision and quality of measurements before IWA can be used to guide the surgical refractive plan in cataract surgery. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  4. Improving quality of reproductive health care in Senegal through formative supervision: results from four districts

    PubMed Central

    Suh, Siri; Moreira, Philippe; Ly, Moussa

    2007-01-01

    Background In Senegal, traditional supervision often focuses more on collection of service statistics than on evaluation of service quality. This approach yields limited information on quality of care and does little to improve providers' competence. In response to this challenge, Management Sciences for Health (MSH) has implemented a program of formative supervision. This multifaceted, problem-solving approach collects data on quality of care, improves technical competence, and engages the community in improving reproductive health care. Methods This study evaluated changes in service quality and community involvement after two rounds of supervision in 45 health facilities in four districts of Senegal. We used checklists to assess quality in four areas of service delivery: infrastructure, staff and services management, record-keeping, and technical competence. We also measured community involvement in improving service quality using the completion rates of action plans. Results The most notable improvement across regions was in infection prevention. Management of staff, services, and logistics also consistently improved across the four districts. Record-keeping skills showed variable but lower improvement by region. The completion rates of action plans suggest that communities are engaged in improving service quality in all four districts. Conclusion Formative supervision can improve the quality of reproductive health services, especially in areas where there is on-site skill building and refresher training. This approach can also mobilize communities to participate in improving service quality. PMID:18047678

  5. Quantitative assessment of the impact of biomedical image acquisition on the results obtained from image analysis and processing.

    PubMed

    Koprowski, Robert

    2014-07-04

    Dedicated, automatic algorithms for image analysis and processing are becoming more and more common in medical diagnosis. When creating dedicated algorithms, many factors must be taken into consideration. They are associated with selecting the appropriate algorithm parameters and taking into account the impact of data acquisition on the results obtained. An important feature of algorithms is the possibility of their use in other medical units by other operators. This problem, namely operator's (acquisition) impact on the results obtained from image analysis and processing, has been shown on a few examples. The analysed images were obtained from a variety of medical devices such as thermal imaging, tomography devices and those working in visible light. The objects of imaging were cellular elements, the anterior segment and fundus of the eye, postural defects and others. In total, almost 200'000 images coming from 8 different medical units were analysed. All image analysis algorithms were implemented in C and Matlab. For various algorithms and methods of medical imaging, the impact of image acquisition on the results obtained is different. There are different levels of algorithm sensitivity to changes in the parameters, for example: (1) for microscope settings and the brightness assessment of cellular elements there is a difference of 8%; (2) for the thyroid ultrasound images there is a difference in marking the thyroid lobe area which results in a brightness assessment difference of 2%. The method of image acquisition in image analysis and processing also affects: (3) the accuracy of determining the temperature in the characteristic areas on the patient's back for the thermal method - error of 31%; (4) the accuracy of finding characteristic points in photogrammetric images when evaluating postural defects - error of 11%; (5) the accuracy of performing ablative and non-ablative treatments in cosmetology - error of 18% for the nose, 10% for the cheeks, and 7% for the

  6. Quality-assurance results for routine water analysis in US Geological Survey laboratories, water year 1991

    USGS Publications Warehouse

    Maloney, T.J.; Ludtke, A.S.; Krizman, T.L.

    1994-01-01

    The US. Geological Survey operates a quality- assurance program based on the analyses of reference samples for the National Water Quality Laboratory in Arvada, Colorado, and the Quality of Water Service Unit in Ocala, Florida. Reference samples containing selected inorganic, nutrient, and low ionic-strength constituents are prepared and disguised as routine samples. The program goal is to determine precision and bias for as many analytical methods offered by the participating laboratories as possible. The samples typically are submitted at a rate of approximately 5 percent of the annual environmental sample load for each constituent. The samples are distributed to the laboratories throughout the year. Analytical data for these reference samples reflect the quality of environmental sample data produced by the laboratories because the samples are processed in the same manner for all steps from sample login through data release. The results are stored permanently in the National Water Data Storage and Retrieval System. During water year 1991, 86 analytical procedures were evaluated at the National Water Quality Laboratory and 37 analytical procedures were evaluated at the Quality of Water Service Unit. An overall evaluation of the inorganic (major ion and trace metal) constituent data for water year 1991 indicated analytical imprecision in the National Water Quality Laboratory for 5 of 67 analytical procedures: aluminum (whole-water recoverable, atomic emission spectrometric, direct-current plasma); calcium (atomic emission spectrometric, direct); fluoride (ion-exchange chromatographic); iron (whole-water recoverable, atomic absorption spectrometric, direct); and sulfate (ion-exchange chromatographic). The results for 11 of 67 analytical procedures had positive or negative bias during water year 1991. Analytical imprecision was indicated in the determination of two of the five National Water Quality Laboratory nutrient constituents: orthophosphate as phosphorus and

  7. Improving the Quality of Protein Crystals Using Stirring Crystallization

    NASA Astrophysics Data System (ADS)

    Adachi, Hiroaki; Matsumura, Hiroyoshi; Niino, Ai; Takano, Kazufumi; Kinoshita, Takayoshi; Warizaya, Masaichi; Inoue, Tsuyoshi; Mori, Yusuke; Sasaki, Takatomo

    2004-04-01

    Recent reports state that a high magnetic field improves the crystal quality of bovine adenosine deaminase (ADA) with an inhibitor [Kinoshita et al.: Acta Cryst. D59 (2003) 1333]. In this paper, we examine the effect of stirring solution on ADA crystallization using a vapor-diffusion technique with rotary and figure-eight motion shakers. The probability of obtaining high-quality crystals is increased with stirring in a figure-eight pattern. Furthermore, rotary stirring greatly increased the probability of obtaining high-quality crystals, however, nucleation time was also increased. The crystal structure with the inhibitor was determined at a high resolution using a crystal obtained from a stirred solution. These results indicate that stirring with simple equipment is as useful as the high magnetic field technique for protein crystallization.

  8. Image quality on the Kuiper Airborne Observatory. I - Results of the first flight series

    NASA Technical Reports Server (NTRS)

    Elliot, J. L.; Dunham, E. W.; Baron, R. L.; Watts, A. W.; Kruse, S. E.; Rose, W. C.; Gillespie, C. M., Jr.

    1989-01-01

    The NASA Kuiper Airborne Observatory (KAO) was flown three times during June and July, 1984 in order to study the causes of the poor seeing obtained with the 0.9-m telescope. High-speed pressure and temperature sensors were placed in the telescope cavity. Several thousand stellar images were recorded under various flight and optical configurations. It is found that the long-exposure image size is affected by telescope tracking errors, imperfect optics, poor optical alignment, telescope and instrument vibration, thermal fluctuations in the telescope cavity, and density fluctuations in the shear layer that forms the boundary between the cavity air and outside air. Possible ways to improve the quality of the images are discussed.

  9. Saturn gravity results obtained from Pioneer 11 tracking data and earth-based Saturn satellite data

    NASA Technical Reports Server (NTRS)

    Null, G. W.; Lau, E. L.; Biller, E. D.; Anderson, J. D.

    1981-01-01

    Improved gravity coefficients for Saturn, its satellites and rings are calculated on the basis of a combination of Pioneer 11 spacecraft Doppler tracking data and earth-based determinations of Saturn natural satellite apse and node rates. Solutions are first obtained separately from the coherent Doppler tracking data obtained for the interval from August 20 to September 4, surrounding the time of closest approach, with the effects of solar plasma on radio signal propagation taken into account, and from secular rates for Mimas, Enceladus, Tethys, Dione, Rhea and Titan determined from astrometric data by Kozai (1957, 1976) and Garcia (1972). Combination of the data by the use of the Pioneer solution and corresponding unadjusted covariance matrix as a priori information for a secular rate analysis results in values for the total ring mass of essentially zero at a standard error level of 1.7 x 10 to the -6th Saturn masses, a ratio of solar mass to that of the Saturn system of 3498.09 + or - 0.22, masses of Rhea, Titan and Iapetus of 4.0 + or - 0.9, 238.8 + or - 3, and 3.4 + or - 1.3 x 10 to the -6th Saturn masses, respectively, and second and fourth zonal harmonics of 16,479 + or - 18 and -937 + or - 38, respectively. The harmonic coefficients are noted to be important as boundary conditions in the modeling of the Saturn interior.

  10. Sentinel-2B image quality commissioning phase results and Sentinel2 constellation performances

    NASA Astrophysics Data System (ADS)

    Languille, F.; Gaudel, A.; Vidal, B.; Binet, R.; Poulain, V.; Trémas, T.

    2017-09-01

    In the frame of the Copernicus program of the European Commission, Sentinel-2 is a constellation of 2 satellites on a polar sun-synchronous orbit with a revisit time of 5 days (with both satellites), a high field of view - 290km, 13 spectral bands in visible and shortwave infrared, and high spatial resolution - 10m, 20m and 60m. The Sentinel-2 mission offers a global coverage over terrestrial surfaces. The satellites acquire systematically terrestrial surfaces under the same viewing conditions in order to have temporal images stacks. The first satellite was launched in June 2015 and the second in March 2017. In cooperation with the European Space Agency (ESA), the French space agency (CNES) is in charge of the image quality of the project, and so ensured the CAL/VAL commissioning phase during the months following the launch. This cooperation is also extended to routine phase as CNES supports European Space Research Institute (ESRIN) and the Sentinel-2 Mission performance Centre (MPC) for validation in geometric and radiometric image quality aspects, and in Sentinel-2 Global Reference Image (GRI) geolocation performance assessment. This paper points on geometric image quality on Sentinel-2B commissioning phase. It relates to the methods and the performances obtained, as well as the comparison between S2A and S2B. This deals with geolocation and multispectral registration. A small focus is also done on the Sentinel-2 GRI which is a set of S2A images at 10m resolution covering the whole world with a good and consistent geolocation. This ground reference leads to ensure an accurate multi-temporal registration -on refined Sentinel-2 products over GRI- which is also presented in this paper.

  11. ERTS-1 Virgin Islands experiment 589: Determine boundaries of ERTS and aircraft data within which useful water quality information can be obtained. [water pollution in St. Thomas harbor, Virgin Islands

    NASA Technical Reports Server (NTRS)

    Coulbourn, W. C.; Egan, W. G.; Olsen, D. A. (Principal Investigator); Heaslip, G. B.

    1973-01-01

    The author has identified the following significant results. The boundaries of application of ERTS-1 and aircraft data are established for St. Thomas harbor within which useful water quality information can be obtained. In situ physical, chemical, and biological water quality and benthic data were collected. Moored current meters were employed. Optical measurements of solar irradiance, color test panel radiance and water absorption were taken. Procedures for correlating in situ optical, biological, and chemical data with underflight aircraft I2S data and ERTS-1 MSS scanner data are presented. Comparison of bulk and precision CCT computer printout data for this application is made, and a simple method for geometrically locating bulk data individual pixels based on land-water interface is described. ERTS spacecraft data and I2S aircraft imagery are correlated with optical in situ measurements of the harbor water, with the aircraft green photographic and ERTS-1 MSS-4 bands being the most useful. The biological pigments correlate inversely with the optical data for inshore areas and directly further seaward. Automated computer data processing facilitated analysis.

  12. Validation of microbiological testing in cardiovascular tissue banks: results of a quality round trial.

    PubMed

    de By, Theo M M H; McDonald, Carl; Süßner, Susanne; Davies, Jill; Heng, Wee Ling; Jashari, Ramadan; Bogers, Ad J J C; Petit, Pieter

    2017-11-01

    Surgeons needing human cardiovascular tissue for implantation in their patients are confronted with cardiovascular tissue banks that use different methods to identify and decontaminate micro-organisms. To elucidate these differences, we compared the quality of processing methods in 20 tissue banks and 1 reference laboratory. We did this to validate the results for accepting or rejecting tissue. We included the decontamination methods used and the influence of antibiotic cocktails and residues with results and controls. The minor details of the processes were not included. To compare the outcomes of microbiological testing and decontamination methods of heart valve allografts in cardiovascular tissue banks, an international quality round was organized. Twenty cardiovascular tissue banks participated in this quality round. The quality round method was validated first and consisted of sending purposely contaminated human heart valve tissue samples with known micro-organisms to the participants. The participants identified the micro-organisms using their local decontamination methods. Seventeen of the 20 participants correctly identified the micro-organisms; if these samples were heart valves to be released for implantation, 3 of the 20 participants would have decided to accept their result for release. Decontamination was shown not to be effective in 13 tissue banks because of growth of the organisms after decontamination. Articles in the literature revealed that antibiotics are effective at 36°C and not, or less so, at 2-8°C. The decontamination procedure, if it is validated, will ensure that the tissue contains no known micro-organisms. This study demonstrates that the quality round method of sending contaminated tissues and assessing the results of the microbiological cultures is an effective way of validating the processes of tissue banks. Only when harmonization, based on validated methods, has been achieved, will surgeons be able to fully rely on the methods

  13. Category 1 external quality assessment program for serum creatinine.

    PubMed

    González-Lao, Elisabet; Díaz-Garzón, Jorge; Corte, Zoraida; Ricós, Carmen; Perich, Carmen; Álvarez, Virtudes; Simón, Margarita; Minchinela, Joana; García-Lario, José Vicente; Boned, Beatriz; Biosca, Carmen; Cava, Fernando; Fernández-Fernández, Pilar; Fernández-Calle, Pilar

    2017-03-01

    The Commission of Analytical Quality and the Committee of External Quality Programs of Spanish Society of Laboratory Medicine (SEQC) in collaboration with the Dutch Foundation for the Quality organized the first national category 1 External Quality Assessment Programs (EQAP) pilot study. The aim is to evaluate the standardization of serum creatinine measurements in the Spanish laboratories through a category 1 external quality assurance program with commutable material and reference method assigned values. A total of 87 Spanish laboratories were involved in this program in 2015. Each day a sample control was measured by duplicate during 6 consecutive days. Percentage deviations and coefficients of variation obtained were compared with quality specifications derived from biological variation. A total of 1044 creatinine results were obtained. Laboratories were coded in 11 different method-traceability combinations. Only enzymatic methods get all results within the acceptability limits. To participate in a category 1 EQAP is a valuable tool to assess the standardization degree in our country; a big effort should be made to promote laboratories to change their procedures and to use enzymatic creatinine methods, in order to achieve a satisfactory standardization degree for this important analyte.

  14. Higher quality of molecular testing, an unfulfilled priority: Results from external quality assessment for KRAS mutation testing in colorectal cancer.

    PubMed

    Tembuyser, Lien; Ligtenberg, Marjolijn J L; Normanno, Nicola; Delen, Sofie; van Krieken, J Han; Dequeker, Elisabeth M C

    2014-05-01

    Precision medicine is now a key element in clinical oncology. RAS mutational status is a crucial predictor of responsiveness to anti-epidermal growth factor receptor agents in metastatic colorectal cancer. In an effort to guarantee high-quality testing services in molecular pathology, the European Society of Pathology has been organizing an annual KRAS external quality assessment program since 2009. In 2012, 10 formalin-fixed, paraffin-embedded samples, of which 8 from invasive metastatic colorectal cancer tissue and 2 artificial samples of cell line material, were sent to more than 100 laboratories from 26 countries with a request for routine KRAS testing. Both genotyping and clinical reports were assessed independently. Twenty-seven percent of the participants genotyped at least 1 of 10 samples incorrectly. In total, less than 5% of the distributed specimens were genotyped incorrectly. Genotyping errors consisted of false negatives, false positives, and incorrectly genotyped mutations. Twenty percent of the laboratories reported a technical error for one or more samples. A review of the written reports showed that several essential elements were missing, most notably a clinical interpretation of the test result, the method sensitivity, and the use of a reference sequence. External quality assessment serves as a valuable educational tool in assessing and improving molecular testing quality and is an important asset for monitoring quality assurance upon incorporation of new biomarkers in diagnostic services. Copyright © 2014 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  15. Landsat Thematic Mapper monitoring of turbid inland water quality

    NASA Technical Reports Server (NTRS)

    Lathrop, Richard G., Jr.

    1992-01-01

    This study reports on an investigation of water quality calibration algorithms under turbid inland water conditions using Landsat Thematic Mapper (TM) multispectral digital data. TM data and water quality observations (total suspended solids and Secchi disk depth) were obtained near-simultaneously and related using linear regression techniques. The relationships between reflectance and water quality for Green Bay and Lake Michigan were compared with results for Yellowstone and Jackson Lakes, Wyoming. Results show similarities in the water quality-reflectance relationships, however, the algorithms derived for Green Bay - Lake Michigan cannot be extrapolated to Yellowstone and Jackson Lake conditions.

  16. Prediction of Groundwater Quality Trends Resulting from Anthropogenic Changes in Southeast Florida.

    PubMed

    Yi, Quanghee; Stewart, Mark

    2018-01-01

    The effects of surface water flow system changes caused by constructing water-conservation areas and canals in southeast Florida on groundwater quality under the Atlantic Coastal Ridge was investigated with numerical modeling. Water quality data were used to delineate a zone of groundwater with low total dissolved solids (TDS) within the Biscayne aquifer under the ridge. The delineated zone has the following characteristics. Its location generally coincides with an area where the Biscayne aquifer has high transmissivities, corresponds to a high recharge area of the ridge, and underlies a part of the groundwater mound formed under the ridge prior to completion of the canals. This low TDS groundwater appears to be the result of pre-development conditions rather than seepage from the canals constructed after the 1950s. Numerical simulation results indicate that the time for low TDS groundwater under the ridge to reach equilibrium with high TDS surface water in the water-conservation areas and Everglades National Park are approximately 70 and 60 years, respectively. The high TDS groundwater would be restricted to the water-conservation areas and the park due to its slow eastward movement caused by small hydraulic gradients in Rocky Glades and its mixing with the low TDS groundwater under the high-recharge area of the ridge. The flow or physical boundary conditions such as high recharge rates or low hydraulic conductivity layers may affect how the spatial distribution of groundwater quality in an aquifer will change when a groundwater flow system reaches equilibrium with an associated surface water flow system. © 2017, National Ground Water Association.

  17. Changes to indoor air quality as a result of relocating families from slums to public housing

    NASA Astrophysics Data System (ADS)

    Burgos, Soledad; Ruiz, Pablo; Koifman, Rosalina

    2013-05-01

    One largely unstudied benefit of relocating families from slums to public housing is the potential improvement in indoor air quality (IAQ). We compared families that moved from slums to public housing with those that remained living in slums in Santiago, Chile in terms of fine particulate matter (PM2.5) as main indicator of change. A cross-sectional study of 98 relocated families and 71 still living in slums was carried out, obtaining indoor and outdoor samples by a Personal Environmental Monitor. Home characteristics, including indoor air pollution sources were collected through questionnaires. Multivariate regression models included the intervention (public housing or slum), indoor pollution sources, outdoor PM2.5 and family characteristics as predictors. Indoor PM2.5 concentrations were higher in slums (77.8 μg m-3 [SD = 35.7 μg m-3]) than in public housing (55.7 μg m-3 [SD = 34.6 μg m-3], p < 0.001). Differences between indoor and outdoor PM2.5 were significant only in the slum houses. The multivariate analysis showed that housing intervention significantly decreased indoor PM2.5 (10.4 μg m-3) after adjusting by the other predictors. Outdoor PM2.5 was the main predictor of indoor PM2.5. Other significant factors were water heating fuels and indoor smoking. Having infants 1-23 months was associated with a lowering of indoor PM2.5. Our results suggest that a public housing program that moves families from slums to public housing improves indoor air quality directly and also indirectly through air pollution sources.

  18. Engagement Insights: Survey Findings on the Quality of Undergraduate Education. Annual Results 2016

    ERIC Educational Resources Information Center

    National Survey of Student Engagement, 2016

    2016-01-01

    The National Survey of Student Engagement (NSSE) and its companion projects serve colleges and universities committed to monitoring and improving the quality of the undergraduate experience. While participating institutions receive detailed customized reports, the "Annual Results" series presents noteworthy aggregate findings from the…

  19. CAN RAPID MEASURES OF RECREATIONAL WATER QUALITY PREDICT SWIMMING ASSOCIATED GASTROINTESTINAL ILLNESS?

    EPA Science Inventory

    Standard methods to measure recreational water quality require at least 24 hours to obtain results making it impossible to assess the quality of water within a single day. Methods to measure recreational water quality in two hours or less have been developed. Application of rapid...

  20. Quality of claims, references and the presentation of risk results in medical journal advertising: a comparative study in Australia, Malaysia and the United States

    PubMed Central

    2010-01-01

    Background Journal advertising is used by pharmaceutical companies to disseminate medicine information to doctors. The quality of claims, references and the presentation of risk results in Australia and the US has been questioned in several studies. No recent evidence is available on the quality of claims, references and the presentation of risk results in journal advertising in Australia and the US and no Malaysian data have been published. The aim of this study was to compare the quality of claims, references and the presentation of risk results in journal advertising in these three countries. Methods A consecutive sample of 85 unique advertisements from each country was selected from journal advertising published between January 2004 to December 2006. Claims, references and the presentation of risk results in medical journal advertising were compared between the three countries. Results Less than one-third of the claims were unambiguous claims (Australia, 30%, Malaysia 17%, US, 23%). In Malaysia significantly less unambiguous claims were provided than in Australia and the US (P < 0.001). However, the unambiguous claims were supported by more references than other claims (80%). Most evidence was obtained from at least one randomized controlled trial, a systematic review or meta-analysis (Australia, 84%, Malaysia, 81%, US, 76%) with journal articles being the most commonly cited references in all countries. Data on file were significantly more likely to be cited in the US (17%) than in Australia (2%) and Malaysia (4%) (P < 0.001). Advertisements that provided quantitative information reported risk results exclusively as a relative risk reduction Conclusions The majority of claims were vague suggesting poor quality of claims in journal advertising in these three countries. Evidence from a randomized controlled trial, systematic review or meta- analysis was commonly cited to support claims. However, the more frequent use of data that have not been published and

  1. Quality of Life and Symptoms in Long-term Survivors of Colorectal Cancer: Results from NSABP Protocol LTS-01

    PubMed Central

    Kunitake, Hiroko; Russell, Marcia M.; Zheng, Ping; Yothers, Greg; Land, Stephanie R.; Petersen, Laura; Fehrenbacher, Louis; Giguere, Jeffery K.; Wickerham, D. Lawrence; Ko, Clifford Y.; Ganz, Patricia A.

    2016-01-01

    Purpose Little is known about health-related quality of life (HRQL) in long-term survivors (LTS) of colorectal cancer (CRC). Methods Long-term CRC survivors (≥ 5 years) treated in previous National Surgical Adjuvant Breast and Bowel Project trials were recruited from 60 sites. After obtaining consent, a telephone survey was administered, which included HRQL instruments to measure physical health (Instrumental Activities of Daily Living [IADL], SF-12 Physical Component Scale [PCS], SF-36 Vitality Scale), mental health (SF-12 Mental Component Scale [MCS], Life Orientation Test, and Impact of Cancer), and clinical symptoms (Fatigue Symptom Inventory [FSI], European Organisation for Research and Treatment of Cancer Colorectal Module [EORTC-CR38], and Brief Pain Inventory). A multivariable model identified predictors of overall quality of life (global health rating). Results Participants (N=708) had significantly higher HRQL compared with age group-matched non-cancer controls with higher mean scores on SF-12 PCS (49.5 vs. 43.7, p=< 0.05), MCS (55.6 vs. 52.1, p=<0.05) and SF-36 Vitality scale (67.1 vs. 59.9, p=< 0.05). Multivariable modeling has demonstrated that better overall physical and mental health (PCS and MCS), positive body image (EORTC-CR38 scale), and less fatigue (FSI), were strongly associated with overall quality of life as measured by the global health rating. Interestingly, ability to perform IADLs, experience of cancer, gastrointestinal complaints, and pain were not important predictors. Conclusions In long-term CRC survivors, overall physical and mental health were excellent compared with general population. Other disease-related symptoms did not detract from good overall health. PMID:27562475

  2. European external quality control study on the competence of laboratories to recognize rare sequence variants resulting in unusual genotyping results.

    PubMed

    Márki-Zay, János; Klein, Christoph L; Gancberg, David; Schimmel, Heinz G; Dux, László

    2009-04-01

    Depending on the method used, rare sequence variants adjacent to the single nucleotide polymorphism (SNP) of interest may cause unusual or erroneous genotyping results. Because such rare variants are known for many genes commonly tested in diagnostic laboratories, we organized a proficiency study to assess their influence on the accuracy of reported laboratory results. Four external quality control materials were processed and sent to 283 laboratories through 3 EQA organizers for analysis of the prothrombin 20210G>A mutation. Two of these quality control materials contained sequence variants introduced by site-directed mutagenesis. One hundred eighty-nine laboratories participated in the study. When samples gave a usual result with the method applied, the error rate was 5.1%. Detailed analysis showed that more than 70% of the failures were reported from only 9 laboratories. Allele-specific amplification-based PCR had a much higher error rate than other methods (18.3% vs 2.9%). The variants 20209C>T and [20175T>G; 20179_20180delAC] resulted in unusual genotyping results in 67 and 85 laboratories, respectively. Eighty-three (54.6%) of these unusual results were not recognized, 32 (21.1%) were attributed to technical issues, and only 37 (24.3%) were recognized as another sequence variant. Our findings revealed that some of the participating laboratories were not able to recognize and correctly interpret unusual genotyping results caused by rare SNPs. Our study indicates that the majority of the failures could be avoided by improved training and careful selection and validation of the methods applied.

  3. Experimental Results Obtained with Air Liquide Cold Compression System: CERN LHC and SNS Projects

    NASA Astrophysics Data System (ADS)

    Delcayre, F.; Courty, J.-C.; Hamber, F.; Hilbert, B.; Monneret, E.; Toia, J.-L.

    2006-04-01

    Large scale collider facilities will make intensive use of superconducting magnets, operating below 2.0 K. This dictates high-capacity refrigeration systems operating below 2.0 K. These systems, making use of cryogenic centrifugal compressors in a series arrangement with room temperature screw compressors will be coupled to a refrigerator, providing a certain power at 4.5 K. A first Air Liquide Cold Compression System (CCS) unit was built and delivered to CERN in 2001. Installed at the beginning of 2002, it was commissioned and tested successfully during year 2002. A series of four sets of identical CCS were then tested in 2004. Another set of four cryogenic centrifugal compressors (CCC) has been delivered to Thomas Jefferson National Accelerator Facility (JLAB) for the Spallation Neutron Source (SNS) in 2002. These compressors were tested and commissioned from December 2004 to July 2005. The experimental results obtained with these systems will be presented and discussed: the characteristics of the CCC will be detailed. The principles of control for the CCC in series will be detailed.

  4. Water Quality, Sanitation, and Hygiene Conditions in Schools and Households in Dolakha and Ramechhap Districts, Nepal: Results from A Cross-Sectional Survey.

    PubMed

    Shrestha, Akina; Sharma, Subodh; Gerold, Jana; Erismann, Séverine; Sagar, Sanjay; Koju, Rajendra; Schindler, Christian; Odermatt, Peter; Utzinger, Jürg; Cissé, Guéladio

    2017-01-18

    This study assessed drinking water quality, sanitation, and hygiene (WASH) conditions among 708 schoolchildren and 562 households in Dolakha and Ramechhap districts of Nepal. Cross-sectional surveys were carried out in March and June 2015. A Delagua water quality testing kit was employed on 634 water samples obtained from 16 purposively selected schools, 40 community water sources, and 562 households to examine water quality. A flame atomic absorption spectrophotometer was used to test lead and arsenic content of the same samples. Additionally, a questionnaire survey was conducted to obtain WASH predictors. A total of 75% of school drinking water source samples and 76.9% point-of-use samples (water bottles) at schools, 39.5% water source samples in the community, and 27.4% point-of-use samples at household levels were contaminated with thermo-tolerant coliforms. The values of water samples for pH (6.8-7.6), free and total residual chlorine (0.1-0.5 mg/L), mean lead concentration (0.01 mg/L), and mean arsenic concentration (0.05 mg/L) were within national drinking water quality standards. The presence of domestic animals roaming inside schoolchildren's homes was significantly associated with drinking water contamination (adjusted odds ratio: 1.64; 95% confidence interval: 1.08-2.50; p = 0.02). Our findings call for an improvement of WASH conditions at the unit of school, households, and communities.

  5. Initial Results Obtained with the First TWIN VLBI Radio Telescope at the Geodetic Observatory Wettzell

    PubMed Central

    Schüler, Torben; Kronschnabl, Gerhard; Plötz, Christian; Neidhardt, Alexander; Bertarini, Alessandra; Bernhart, Simone; la Porta, Laura; Halsig, Sebastian; Nothnagel, Axel

    2015-01-01

    Geodetic Very Long Baseline Interferometry (VLBI) uses radio telescopes as sensor networks to determine Earth orientation parameters and baseline vectors between the telescopes. The TWIN Telescope Wettzell 1 (TTW1), the first of the new 13.2 m diameter telescope pair at the Geodetic Observatory Wettzell, Germany, is currently in its commissioning phase. The technology behind this radio telescope including the receiving system and the tri-band feed horn is depicted. Since VLBI telescopes must operate at least in pairs, the existing 20 m diameter Radio Telescope Wettzell (RTW) is used together with TTW1 for practical tests. In addition, selected long baseline setups are investigated. Correlation results portraying the data quality achieved during first initial experiments are discussed. Finally, the local 123 m baseline between the old RTW telescope and the new TTW1 is analyzed and compared with an existing high-precision local survey. Our initial results are very satisfactory for X-band group delays featuring a 3D distance agreement between VLBI data analysis and local ties of 1 to 2 mm in the majority of the experiments. However, S-band data, which suffer much from local radio interference due to WiFi and mobile communications, are about 10 times less precise than X-band data and require further analysis, but evidence is provided that S-band data are well-usable over long baselines where local radio interference patterns decorrelate. PMID:26263991

  6. Parallel-scanning tomosynthesis using a slot scanning technique: Fixed-focus reconstruction and the resulting image quality

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shibata, Koichi, E-mail: shibatak@suzuka-u.ac.jp; Notohara, Daisuke; Sakai, Takihito

    2014-11-01

    Purpose: Parallel-scanning tomosynthesis (PS-TS) is a novel technique that fuses the slot scanning technique and the conventional tomosynthesis (TS) technique. This approach allows one to obtain long-view tomosynthesis images in addition to normally sized tomosynthesis images, even when using a system that has no linear tomographic scanning function. The reconstruction technique and an evaluation of the resulting image quality for PS-TS are described in this paper. Methods: The PS-TS image-reconstruction technique consists of several steps (1) the projection images are divided into strips, (2) the strips are stitched together to construct images corresponding to the reconstruction plane, (3) the stitchedmore » images are filtered, and (4) the filtered stitched images are back-projected. In the case of PS-TS using the fixed-focus reconstruction method (PS-TS-F), one set of stitched images is used for the reconstruction planes at all heights, thus avoiding the necessity of repeating steps (1)–(3). A physical evaluation of the image quality of PS-TS-F compared with that of the conventional linear TS was performed using a R/F table (Sonialvision safire, Shimadzu Corp., Kyoto, Japan). The tomographic plane with the best theoretical spatial resolution (the in-focus plane, IFP) was set at a height of 100 mm from the table top by adjusting the reconstruction program. First, the spatial frequency response was evaluated at heights of −100, −50, 0, 50, 100, and 150 mm from the IFP using the edge of a 0.3-mm-thick copper plate. Second, the spatial resolution at each height was visually evaluated using an x-ray test pattern (Model No. 38, PTW Freiburg, Germany). Third, the slice sensitivity at each height was evaluated via the wire method using a 0.1-mm-diameter tungsten wire. Phantom studies using a knee phantom and a whole-body phantom were also performed. Results: The spatial frequency response of PS-TS-F yielded the best results at the IFP and degraded slightly as

  7. Learning Receptive Fields and Quality Lookups for Blind Quality Assessment of Stereoscopic Images.

    PubMed

    Shao, Feng; Lin, Weisi; Wang, Shanshan; Jiang, Gangyi; Yu, Mei; Dai, Qionghai

    2016-03-01

    Blind quality assessment of 3D images encounters more new challenges than its 2D counterparts. In this paper, we propose a blind quality assessment for stereoscopic images by learning the characteristics of receptive fields (RFs) from perspective of dictionary learning, and constructing quality lookups to replace human opinion scores without performance loss. The important feature of the proposed method is that we do not need a large set of samples of distorted stereoscopic images and the corresponding human opinion scores to learn a regression model. To be more specific, in the training phase, we learn local RFs (LRFs) and global RFs (GRFs) from the reference and distorted stereoscopic images, respectively, and construct their corresponding local quality lookups (LQLs) and global quality lookups (GQLs). In the testing phase, blind quality pooling can be easily achieved by searching optimal GRF and LRF indexes from the learnt LQLs and GQLs, and the quality score is obtained by combining the LRF and GRF indexes together. Experimental results on three publicly 3D image quality assessment databases demonstrate that in comparison with the existing methods, the devised algorithm achieves high consistent alignment with subjective assessment.

  8. The Mini-OAKHQOL for knee and hip osteoarthritis quality of life was obtained following recent shortening guidelines.

    PubMed

    Guillemin, Francis; Rat, Anne-Christine; Goetz, Christophe; Spitz, Elisabeth; Pouchot, Jacques; Coste, Joël

    2016-01-01

    To develop a short form of the knee and hip osteoarthritis quality of life questionnaire, the Mini-OAKHQOL, preserving the conceptual model and, as far as possible, the content and the psychometric properties of the original instrument. A two-step shortening procedure was used: (1) a consensus Delphi method, with a panel of patients and another of professionals independently asked to select items and (2) a nominal group, where patients, professionals, and methodologists reached consensus on the final selection of items, using information from the panels and from modern measurement and classical test theory analyses. The psychometric properties of the Mini-OAKHQOL were assessed in an independent population-based sample of 581 subjects with knee or hip osteoarthritis. The two-step shortening procedure resulted in a 20-item questionnaire. Confirmatory factor analysis showed preservation of the original five-dimensional structure. Rasch analyses showed the unidimensionality and invariance by sex, age, and joint of the main dimensions. Convergent validity, reproducibility, and internal consistency were similar to or better than those of the original OAKHQOL. The 20-item Mini-OAKHQOL has good psychometric properties and can be used for the measurement of quality of life in subjects with osteoarthritis of the lower limbs. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Towards routine determination of focal mechanisms obtained from first motion P-wave arrivals

    NASA Astrophysics Data System (ADS)

    Lentas, K.

    2018-03-01

    The Bulletin of the International Seismological Centre (ISC) contains information on earthquake mechanisms collected from many different sources including national and global agencies, resulting in a satisfactory coverage over a wide magnitude range (M ˜2-9). Nevertheless, there are still a vast number of earthquakes with no reported source mechanisms especially for magnitudes up to 5. This study investigates the possibility of calculating earthquake focal mechanisms in a routine and systematic way based on P-wave first motion polarities. Any available parametric data in the ISC database is being used, as well as auto-picked polarities from waveform data up to teleseismic epicentral distances (90°) for stations that are not reported to the ISC. The determination of the earthquake mechanisms is carried out with a modified version of the HASH algorithm that is compatible with a wide range of epicentral distances and takes into account the ellipsoids defined by the ISC location errors, and the Earth's structure uncertainties. Initially, benchmark tests for a set of ISC reviewed earthquakes (mb > 4.5) are carried out and the HASH mechanism classification scheme is used to define the mechanism quality. Focal mechanisms of quality A, B and C with an azimuthal gap up to 90° compare well to the benchmark mechanisms. Nevertheless, the majority of the obtained mechanisms fall into class D as a result of limited polarity data from stations in local/regional epicentral distances. Specifically, the computation of the minimum rotation angle between the obtained mechanisms and the benchmarks, reveals that 41 per cent of the examined earthquakes show rotation angles up to 35°. Finally, the current technique is applied to a small set of earthquakes from the reviewed ISC bulletin where 62 earthquakes, with no previously reported source mechanisms, are successfully obtained.

  10. Compression of next-generation sequencing quality scores using memetic algorithm

    PubMed Central

    2014-01-01

    Background The exponential growth of next-generation sequencing (NGS) derived DNA data poses great challenges to data storage and transmission. Although many compression algorithms have been proposed for DNA reads in NGS data, few methods are designed specifically to handle the quality scores. Results In this paper we present a memetic algorithm (MA) based NGS quality score data compressor, namely MMQSC. The algorithm extracts raw quality score sequences from FASTQ formatted files, and designs compression codebook using MA based multimodal optimization. The input data is then compressed in a substitutional manner. Experimental results on five representative NGS data sets show that MMQSC obtains higher compression ratio than the other state-of-the-art methods. Particularly, MMQSC is a lossless reference-free compression algorithm, yet obtains an average compression ratio of 22.82% on the experimental data sets. Conclusions The proposed MMQSC compresses NGS quality score data effectively. It can be utilized to improve the overall compression ratio on FASTQ formatted files. PMID:25474747

  11. An Integrational Model of Quality of Life in Older Age. Results from the Esrc/mrc Hsrc Quality of Life Survey in Britain.(author Abstract)

    ERIC Educational Resources Information Center

    Bowling, Ann; Gabriel, Zahava

    2004-01-01

    This paper is based on the results of a national survey of the quality of life of 999 randomly sampled people aged 65 and over, living at home in Britain. The survey was semi-structured, and a sample of survey respondents was followed up and interviewed in-depth in order to explore their perceptions of quality of life in full. Comparisons are made…

  12. Comparison of the Diagnostic Image Quality of the Canine Maxillary Dentoalveolar Structures Obtained by Cone Beam Computed Tomography and 64-Multidetector Row Computed Tomography.

    PubMed

    Soukup, Jason W; Drees, Randi; Koenig, Lisa J; Snyder, Christopher J; Hetzel, Scott; Miles, Chanda R; Schwarz, Tobias

    2015-01-01

    The objective of this blinded study was to validate the use of cone beam computed tomography (C) for imaging of the canine maxillary dentoalveolar structures by comparing its diagnostic image quality with that of 64-multidetector row CT Sagittal slices of a tooth-bearing segment of the maxilla of a commercially purchased dog skull embedded in methylmethacrylate were obtained along a line parallel with the dental arch using a commercial histology diamond saw. The slice of tooth-bearing bone that best depicted the dentoalveolar structures was chosen and photographed. The maxillary segment was imaged with cone beam CT and 64-multidetector row CT. Four blinded evaluators compared the cone beam CT and 64-multidetector row CT images and image quality was scored as it related to the anatomy of dentoalveolar structures. Trabecular bone, enamel, dentin, pulp cavity, periodontal ligament space, and lamina dura were scored In addition, a score depicting the evaluators overall impression of the image was recorded. Images acquired with cone beam CT were found to be significantly superior in image quality to images acquired with 64-multidetector row CT overall, and in all scored categories. In our study setting cone beam CT was found to be a valid and clinically superior imaging modality for the canine maxillary dentoalveolar structures when compared to 64-multidetector row CT.

  13. Comparison of the Diagnostic Image Quality of the Canine Maxillary Dentoalveolar Structures Obtained by Cone Beam Computed Tomography and 64-Multidetector Row Computed Tomography

    PubMed Central

    Soukup, Jason W.; Drees, Randi; Koenig, Lisa J.; Snyder, Christopher J.; Hetzel, Scott; Miles, Chanda R.; Schwarz, Tobias

    2016-01-01

    Summary The objective of this blinded study was to validate the use of cone beam computed tomography (CT) for imaging of the canine maxillary dentoalveolar structures by comparing its diagnostic image quality with that of 64-multidetector row CT. Sagittal slices of a tooth-bearing segment of the maxilla of a commercially purchased dog skull embedded in methyl methacrylate were obtained along a line parallel with the dental arch using a commercial histology diamond saw. The slice of tooth-bearing bone that best depicted the dentoalveolar structures was chosen and photographed. The maxilla segment was imaged with cone beam CT and 64-multidetector row CT. Four blinded evaluators compared the cone beam CT and 64-multidetector row CT images and image quality was scored as it related to the anatomy of dentoalveolar structures. Trabecular bone, enamel, dentin, pulp cavity, periodontal ligament space, and lamina dura were scored. In addition, a score depicting the evaluators overall impression of the image was recorded. Images acquired with cone beam CT were found to be significantly superior in image quality to images acquired with 64-multidetector row CT overall, and in all scored categories. In our study setting, cone beam CT was found to be a valid and clinically superior imaging modality for the canine maxillary dentoalveolar structures when compared to 64-multidetector row CT. PMID:26415384

  14. Total Quality Management Elements and Results in Higher Education Institutions: The Greek Case

    ERIC Educational Resources Information Center

    Psomas, Evangelos; Antony, Jiju

    2017-01-01

    Purpose: The purpose of this paper is to determine the main total quality management (TQM) elements adopted and the respective results achieved by higher education institutions (HEIs) in Greece. Design/methodology/approach: A research study was designed and carried out in private sector Greek HEIs. Fifteen HEIs were approached through interviews…

  15. Quantification of active pharmaceutical ingredient and impurities in sildenafil citrate obtained from the Internet

    PubMed Central

    Nutan, Mohammad T.; Dodla, Uday Krishna Reddy

    2014-01-01

    Background: The accessibility of prescription drugs produced outside of the United States, most notably sildenafil citrate (innovator product, Viagra®), has been made much easier by the Internet. Of greatest concern to clinicians and policymakers is product quality and patient safety. The US Food and Drug Administration (FDA) has issued warnings to potential buyers that the safety of drugs purchased from the Internet cannot be guaranteed, and may present a health risk to consumers from substandard products. Objective: The objective of this study was to determine whether generic sildenafil citrate tablets from international markets obtained via the Internet are equivalent to the US innovator product regarding major aspects of pharmaceutical quality: potency, accuracy of labeling, and presence and level of impurities. This will help identify aspects of drug quality that may impact public health risks. Methods: A total of 15 sildenafil citrate tablets were obtained for pharmaceutical analysis: 14 generic samples from international Internet pharmacy websites and the US innovator product. According to US Pharmacopeial guidelines, tablet samples were tested using high-performance liquid chromatography for potency of active pharmaceutical ingredient (API) and levels of impurities (impurities A, B, C, and D). Impurity levels were compared with International Conference on Harmonisation (ICH) limits. Results: Among the 15 samples, 4 samples possessed higher impurity B levels than the ICH qualification threshold, 8 samples possessed higher impurity C levels than the ICH qualification threshold, and 4 samples possessed more than 1% impurity quantity of maximum daily dose (MDD). For API, 6 of the samples failed to fall within the 5% assay limit. Conclusions: Quality assurance tests are often used to detect formulation defects of drug products during the manufacturing and/or storage process. Results suggest that manufacturing standards for sildenafil citrate generic drug

  16. A cross-sectional study assessing the association between online ratings and structural and quality of care measures: results from two German physician rating websites.

    PubMed

    Emmert, Martin; Adelhardt, Thomas; Sander, Uwe; Wambach, Veit; Lindenthal, Jörg

    2015-09-24

    Even though physician rating websites (PRWs) have been gaining in importance in both practice and research, little evidence is available on the association of patients' online ratings with the quality of care of physicians. It thus remains unclear whether patients should rely on these ratings when selecting a physician. The objective of this study was to measure the association between online ratings and structural and quality of care measures for 65 physician practices from the German Integrated Health Care Network "Quality and Efficiency" (QuE). Online reviews from two German PRWs were included which covered a three-year period (2011 to 2013) and included 1179 and 991 ratings, respectively. Information for 65 QuE practices was obtained for the year 2012 and included 21 measures related to structural information (N = 6), process quality (N = 10), intermediate outcomes (N = 2), patient satisfaction (N = 1), and costs (N = 2). The Spearman rank coefficient of correlation was applied to measure the association between ratings and practice-related information. Patient satisfaction results from offline surveys and the patients per doctor ratio in a practice were shown to be significantly associated with online ratings on both PRWs. For one PRW, additional significant associations could be shown between online ratings and cost-related measures for medication, preventative examinations, and one diabetes type 2-related intermediate outcome measure. There again, results from the second PRW showed significant associations with the age of the physicians and the number of patients per practice, four process-related quality measures for diabetes type 2 and asthma, and one cost-related measure for medication. Several significant associations were found which varied between the PRWs. Patients interested in the satisfaction of other patients with a physician might select a physician on the basis of online ratings. Even though our results indicate associations

  17. Paternity tests in Mexico: Results obtained in 3005 cases.

    PubMed

    García-Aceves, M E; Romero Rentería, O; Díaz-Navarro, X X; Rangel-Villalobos, H

    2018-04-01

    National and international reports regarding the paternity testing activity scarcely include information from Mexico and other Latin American countries. Therefore, we report different results from the analysis of 3005 paternity cases analyzed during a period of five years in a Mexican paternity testing laboratory. Motherless tests were the most frequent (77.27%), followed by trio cases (20.70%); the remaining 2.04% included different cases of kinship reconstruction. The paternity exclusion rate was 29.58%, higher but into the range reported by the American Association of Blood Banks (average 24.12%). We detected 65 mutations, most of them involving one-step (93.8% and the remaining were two-step mutations (6.2%) thus, we were able to estimate the paternal mutation rate for 17 different STR loci: 0.0018 (95% CI 0.0005-0.0047). Five triallelic patterns and 12 suspected null alleles were detected during this period; however, re-amplification of these samples with a different Human Identification (HID) kit confirmed the homozygous genotypes, which suggests that most of these exclusions actually are one-step mutations. HID kits with ≥20 STRs detected more exclusions, diminishing the rate of inconclusive results with isolated exclusions (<3 loci), and leading to higher paternity indexes (PI). However, the Powerplex 21 kit (20 STRs) and Powerplex Fusion kit (22 STRs) offered similar PI (p = 0.379) and average number of exclusions (PE) (p = 0.339) when a daughter was involved in motherless tests. In brief, besides to report forensic parameters from paternity tests in Mexico, results describe improvements to solve motherless paternity tests using HID kits with ≥20 STRs instead of one including 15 STRs. Copyright © 2018 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  18. Results of the First Italian External Quality Assurance Scheme for somatic EGFR mutation testing in non-small-cell lung cancer.

    PubMed

    Normanno, Nicola; Pinto, Carmine; Taddei, Gianluigi; Gambacorta, Marcello; Castiglione, Francesca; Barberis, Massimo; Clemente, Claudio; Marchetti, Antonio

    2013-06-01

    The Italian Association of Medical Oncology (AIOM) and the Italian Society of Pathology and Cytology organized an external quality assessment (EQA) scheme for EGFR mutation testing in non-small-cell lung cancer. Ten specimens, including three small biopsies with known epidermal growth factor receptor (EGFR) mutation status, were validated in three referral laboratories and provided to 47 participating centers. The participants were requested to perform mutational analysis, using their usual method, and to submit results within a 4-week time frame. According to a predefined scoring system, two points were assigned to correct genotype and zero points to false-negative or false-positive results. The threshold to pass the EQA was set at higher than 18 of 20 points. Two rounds were preplanned. All participating centers submitted the results within the time frame. Polymerase chain reaction (PCR)/sequencing was the main methodology used (n = 37 laboratories), although a few centers did use pyrosequencing (n = 8) or real-time PCR (n = 2). A significant number of analytical errors were observed (n = 20), with a high frequency of false-positive results (n = 16). The lower scores were obtained for the small biopsies. Fourteen of 47 centers (30%) that did not pass the first round, having a score less than or equal to 18 points, used PCR/sequencing, whereas 10 of 10 laboratories, using pyrosequencing or real-time PCR, passed the first round. Eight laboratories passed the second round. Overall, 41of 47 centers (87%) passed the EQA. The results of the EQA for EGFR testing in non-small-cell lung cancer suggest that good quality EGFR mutational analysis is performed in Italian laboratories, although differences between testing methods were observed, especially for small biopsies.

  19. Feasibility and accuracy of molecular testing in specimens obtained with small biopsy forceps: comparison with the results of surgical specimens.

    PubMed

    Oki, Masahide; Yatabe, Yasushi; Saka, Hideo; Kitagawa, Chiyoe; Kogure, Yoshihito; Ichihara, Shu; Moritani, Suzuko

    2015-01-01

    During bronchoscopy, small biopsy forceps are increasingly used for the diagnosis of peripheral pulmonary lesions. However, it is unclear whether the formalin-fixed paraffin-embedded specimens sampled with the small biopsy forceps are suitable for the determination of genotypes which become indispensable for the management decision regarding patients with non-small cell lung cancer. The aim of this study was to evaluate the feasibility and accuracy of molecular testing in the specimens obtained with 1.5-mm small biopsy forceps. We examined specimens in 91 patients, who were enrolled in our previous 3 studies on the usefulness of thin bronchoscopes and given a diagnosis of non-small cell lung cancer by bronchoscopy with the 1.5-mm biopsy forceps, and then underwent surgical resection. An experienced pathologist examined paraffin-embedded specimens obtained by bronchoscopic biopsy or surgical resection in a blind fashion on epidermal growth factor receptor (EGFR) mutations, anaplastic lymphoma kinase (ALK) rearrangements and KRAS mutations. Twenty-five (27%), 2 (2%) and 5 (5%) patients had an EGFR mutation, ALK rearrangement and KRAS mutation, respectively, based on the results in surgical specimens. EGFR, ALK and KRAS testing with bronchoscopic specimens was feasible in 82 (90%), 86 (95%) and 83 (91%) patients, respectively. If molecular testing was feasible, the accuracy of EGFR, ALK and KRAS testing with bronchoscopic specimens for the results with surgical specimens was 98, 100 and 98%, respectively. The results of molecular testing in the formalin-fixed paraffin-embedded specimens obtained with the small forceps, in which the genotype could be evaluated, correlated well with those in surgically resected specimens.

  20. Experimental results supporting the determination of service quality objectives for DBS systems

    NASA Technical Reports Server (NTRS)

    Chouinard, G.; Whyte, W. A., Jr.; Goldberg, A. A.; Jones, B. L.

    1985-01-01

    A summary of the results of a joint United States and Canadian program on subjective measurements of the picture degradation caused by noise and interference on an NTSC encoded color television signal is given in this paper. The effects of system noise, cochannel and adjacent channel interference, and both single entry and aggregate as well as a combination of these types of interference were subjectively evaluated by expert and nonexpert viewers under reference conditions. These results were used to develop the rationale used at RARC '83 to establish the service quality objective for planning the DBS service for the American continents.

  1. Quality-control results for ground-water and surface-water data, Sacramento River Basin, California, National Water-Quality Assessment, 1996-1998

    USGS Publications Warehouse

    Munday, Cathy; Domagalski, Joseph L.

    2003-01-01

    Evaluating the extent that bias and variability affect the interpretation of ground- and surface-water data is necessary to meet the objectives of the National Water-Quality Assessment (NAWQA) Program. Quality-control samples used to evaluate the bias and variability include annual equipment blanks, field blanks, field matrix spikes, surrogates, and replicates. This report contains quality-control results for the constituents critical to the ground- and surface-water components of the Sacramento River Basin study unit of the NAWQA Program. A critical constituent is one that was detected frequently (more than 50 percent of the time in blank samples), was detected at amounts exceeding water-quality standards or goals, or was important for the interpretation of water-quality data. Quality-control samples were collected along with ground- and surface-water samples during the high intensity phase (cycle 1) of the Sacramento River Basin NAWQA beginning early in 1996 and ending in 1998. Ground-water field blanks indicated contamination of varying levels of significance when compared with concentrations detected in environmental ground-water samples for ammonia, dissolved organic carbon, aluminum, and copper. Concentrations of aluminum in surface-water field blanks were significant when compared with environmental samples. Field blank samples collected for pesticide and volatile organic compound analyses revealed no contamination in either ground- or surface-water samples that would effect the interpretation of environmental data, with the possible exception of the volatile organic compound trichloromethane (chloroform) in ground water. Replicate samples for ground water and surface water indicate that variability resulting from sample collection, processing, and analysis was generally low. Some of the larger maximum relative percentage differences calculated for replicate samples occurred between samples having lowest absolute concentration differences and(or) values near

  2. 75 FR 19369 - Certain Hot-Rolled Flat-Rolled Carbon Quality Steel Products from Brazil: Preliminary Results of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-14

    ...-Rolled Carbon Quality Steel Products from Brazil: Preliminary Results of Antidumping Duty Administrative... duty order on certain hot-rolled flat-rolled carbon quality steel products (hot-rolled steel) from... 1, 2008, through February 28, 2009. We preliminarily determine that the sale of hot-rolled steel...

  3. Cumulative atomic multipole moments complement any atomic charge model to obtain more accurate electrostatic properties

    NASA Technical Reports Server (NTRS)

    Sokalski, W. A.; Shibata, M.; Ornstein, R. L.; Rein, R.

    1992-01-01

    The quality of several atomic charge models based on different definitions has been analyzed using cumulative atomic multipole moments (CAMM). This formalism can generate higher atomic moments starting from any atomic charges, while preserving the corresponding molecular moments. The atomic charge contribution to the higher molecular moments, as well as to the electrostatic potentials, has been examined for CO and HCN molecules at several different levels of theory. The results clearly show that the electrostatic potential obtained from CAMM expansion is convergent up to R-5 term for all atomic charge models used. This illustrates that higher atomic moments can be used to supplement any atomic charge model to obtain more accurate description of electrostatic properties.

  4. 40 CFR 1515.10 - What information is available, and how can it be obtained?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... can it be obtained? 1515.10 Section 1515.10 Protection of Environment COUNCIL ON ENVIRONMENTAL QUALITY... Council on Environmental Quality will permit copying of any available material but will reserve the right... the Freedom of Information Act as amended (5 U.S.C. 552(b)). (c) The legislative history of the...

  5. High-quality poly-dispersed mixtures applied in additive 3D technologies.

    NASA Astrophysics Data System (ADS)

    Gerasimov, M. D.; Brazhnik, Yu V.; Gorshkov, P. S.; Latyshev, S. S.

    2018-03-01

    The paper describes the new mixer design to obtain high-quality poly-dispersed powders applied in additive 3D technologies. It also considers a new mixing principle of dry powder particles ensuring the distribution of such particles in the total volume, which is close to ideal. The paper presents the mathematical model of mixer operation providing for the quality assessment of the ready mixtures. Besides, it demonstrates experimental results and obtained rational values of mixer process parameters.

  6. A Quality Screening Service for Remote Sensing Data

    NASA Technical Reports Server (NTRS)

    Lynnes, Christopher; Olsen, Edward; Fox, Peter; Vollmer, Bruce; Wolfe, Robert; Samadi, Shahin

    2010-01-01

    NASA provides a wide variety of Earth-observing satellite data products to a diverse community. These data are annotated with quality information in a variety of ways, with the result that many users struggle to understand how to properly account for quality when dealing with satellite data. To address this issue, a Data Quality Screening Service (DQSS) is being implemented for a number of datasets. The DQSS will enable users to obtain data files in which low-quality pixels have been filtered out, based either on quality criteria recommended by the science team or on the user s particular quality criteria. The objective is to increase proper utilization of this critical quality data in science data analysis of satellite data products.

  7. The use of ion beam cleaning to obtain high quality cold welds with minimal deformation

    NASA Technical Reports Server (NTRS)

    Sater, B. L.; Moore, T. J.

    1978-01-01

    A variation of cold welding is described which utilizes an ion beam to clean mating surfaces prior to joining in a vacuum environment. High quality solid state welds were produced with minimal deformation.

  8. Water Quality, Sanitation, and Hygiene Conditions in Schools and Households in Dolakha and Ramechhap Districts, Nepal: Results from A Cross-Sectional Survey

    PubMed Central

    Shrestha, Akina; Sharma, Subodh; Gerold, Jana; Erismann, Séverine; Sagar, Sanjay; Koju, Rajendra; Schindler, Christian; Odermatt, Peter; Utzinger, Jürg; Cissé, Guéladio

    2017-01-01

    This study assessed drinking water quality, sanitation, and hygiene (WASH) conditions among 708 schoolchildren and 562 households in Dolakha and Ramechhap districts of Nepal. Cross-sectional surveys were carried out in March and June 2015. A Delagua water quality testing kit was employed on 634 water samples obtained from 16 purposively selected schools, 40 community water sources, and 562 households to examine water quality. A flame atomic absorption spectrophotometer was used to test lead and arsenic content of the same samples. Additionally, a questionnaire survey was conducted to obtain WASH predictors. A total of 75% of school drinking water source samples and 76.9% point-of-use samples (water bottles) at schools, 39.5% water source samples in the community, and 27.4% point-of-use samples at household levels were contaminated with thermo-tolerant coliforms. The values of water samples for pH (6.8–7.6), free and total residual chlorine (0.1–0.5 mg/L), mean lead concentration (0.01 mg/L), and mean arsenic concentration (0.05 mg/L) were within national drinking water quality standards. The presence of domestic animals roaming inside schoolchildren’s homes was significantly associated with drinking water contamination (adjusted odds ratio: 1.64; 95% confidence interval: 1.08–2.50; p = 0.02). Our findings call for an improvement of WASH conditions at the unit of school, households, and communities. PMID:28106779

  9. Quality of life in chemical warfare survivors with ophthalmologic injuries: the first results form Iran Chemical Warfare Victims Health Assessment Study.

    PubMed

    Mousavi, Batool; Soroush, Mohammad Reza; Montazeri, Ali

    2009-01-19

    Iraq used chemical weapons extensively against the Iranians during the Iran-Iraq war (1980-1988). The aim of this study was to assess the health related quality of life (HRQOL) in people who had ophthalmologic complications due to the sulfur mustard gas exposure during the war. The Veterans and Martyrs Affair Foundation (VMAF) database indicated that there were 196 patients with severe ophthalmologic complications due to chemical weapons exposure. Of these, those who gave consent (n = 147) entered into the study. Quality of life was measured using the 36-item Short Form Health Survey (SF-36) and scores were compared to those of the general public. In addition logistic regression analysis was performed to indicate variables that contribute to physical and mental health related quality of life. The mean age of the patients was 44.8 (SD = 8.7) ranging from 21 to 75 years. About one-third of the cases (n= 50) reported exposure to chemical weapons more than once. The mean exposure duration to sulfur mustard gas was 21.6 years (SD = 1.2). The lowest scores on the SF-36 subscales were found to be: the role physical and the general health. Quality of life in chemical warfare victims who had ophthalmologic problems was significantly lower than the general public (P < 0.001). The results obtained from logistic regression analysis indicated that those who did not participate in sport activities suffer from a poorer physical health (OR = 2.93, 95% CI = 1.36 to 6.30, P = 0.006). The analysis also showed that poor mental health was associated with longer time since exposure (OR = 1.58, 95% CI = 1.04 to 2.39, P = 0.03) and lower education (OR = 3.03, 95% CI = 1.21 to 7.56, P = 0.01). The study findings suggest that chemical warfare victims with ophthalmologic complications suffer from poor health related quality of life. It seems that the need for provision of health and support for this population is urgent. In addition, further research is necessary to measure health related

  10. Image gathering and restoration - Information and visual quality

    NASA Technical Reports Server (NTRS)

    Mccormick, Judith A.; Alter-Gartenberg, Rachel; Huck, Friedrich O.

    1989-01-01

    A method is investigated for optimizing the end-to-end performance of image gathering and restoration for visual quality. To achieve this objective, one must inevitably confront the problems that the visual quality of restored images depends on perceptual rather than mathematical considerations and that these considerations vary with the target, the application, and the observer. The method adopted in this paper is to optimize image gathering informationally and to restore images interactively to obtain the visually preferred trade-off among fidelity resolution, sharpness, and clarity. The results demonstrate that this method leads to significant improvements in the visual quality obtained by the traditional digital processing methods. These traditional methods allow a significant loss of visual quality to occur because they treat the design of the image-gathering system and the formulation of the image-restoration algorithm as two separate tasks and fail to account for the transformations between the continuous and the discrete representations in image gathering and reconstruction.

  11. Water quality monitoring of Sweetwater and Loveland reservoirs--Phase one results 1998-1999

    USGS Publications Warehouse

    Majewski, Michael S.; Sidhu, Jagdeep S.; Mendez, Gregory O.

    2002-01-01

    In 1998, the U.S. Geological Survey began a study to assess the overall health of the watershed feeding the Sweetwater Reservoir in southern San Diego County, California. The study focussed on monitoring for organic chemical contamination and the effects of construction and operation of State Route 125 on water quality. Three environmental compartments (air, water, and bed sediments) are being sampled regularly for chemical contaminants, including volatile organic compounds, polynuclear aromatic hydrocarbons, polychlorinated biphenyls, pesticides, and major and trace elements. The study is divided into two phases. Phase I sampling is designed to establish baseline conditions for target compounds in terms of detection frequency and concentration in air, water, and bed sediments. Phase II sampling will continue at the established monitoring sites during and after construction of State Route 125 to assess chemical impact on water quality in the reservoir resulting from land-use changes and development in the watershed. This report describes the study design, the sampling and analytical methods, and presents the data results for the first year of the study, September 1998 to September 1999.

  12. [Health insurance dentists' subjective perceptions of quality when implementing quality management in practice - results from a nationwide survey].

    PubMed

    Kettler, Nele; Chenot, Regine; Jordan, A Rainer

    2015-01-01

    Statutory health insurance dentists working in private practice have a duty to maintain and improve the quality of dental care. An individual practice's approach to quality management (QM) can be made to reflect the practice's philosophy on quality and standards and can be adapted to the specific requirements of the practice setting they are meant to serve. This study set out to collect data on the subjective perceptions of quality that exist among German dentists, and to canvass their views on the process and benefits of implementing QM systems. In doing so, this study aimed to identify the incentives and obstacles that currently exist in relation to the implementation and further development of practice-based QM systems. As part of a nationally representative cross-sectional study, a random sample of 2,084 dentists was asked to complete a questionnaire on perceptions of quality and QM. The response rate was 40.3 % (n=838). The study's primary end point was defined as the surveyed dentists' interpretative description of quality. The study's secondary end point was defined as the dentists' subjective evaluations of the benefits of QM in the day-to-day management of their own practices. Responses to open-ended questions were analysed using content analysis, while quantitative questions were analysed using descriptive univariate analysis. When analysing respondents' subjective perceptions of quality (primary end point), the following dimensions were revealed as highly significant: patient (mentioned by 31.4 % of the responders), quality of treatment (29.5 %) and staff (14.8 %). As far as the benefits of QM in the day-to-day management of the respondent's own practices (secondary end point) were concerned, these appeared to be linked to the ease of implementation of the organizational tools offered by QM systems: managing emergencies, team meetings and procedural check lists were ranked as "can be implemented to a reasonable degree" and "can be fully implemented

  13. Preventing falls in assisted living: Results of a quality improvement pilot study.

    PubMed

    Zimmerman, Sheryl; Greene, Angela; Sloane, Philip D; Mitchell, Madeline; Giuliani, Carol; Nyrop, Kirsten; Walsh, Edith

    Residents of assisted living (AL) communities are at high risk for falls, which result in negative outcomes and high health care costs. Adapting effective falls prevention programs for AL quality improvement (QI) has the potential to reduce falls, improve resident quality of life, and reduce costs. This project tested the feasibility and outcomes of an evidence-based multi-component QI program, the Assisted Living Falls Prevention and Monitoring Program (AL-FPMP). Resident posture and gait improved, likely due to exercise and/or physical therapy. Effective falls prevention QI programs can be implemented in AL, and are advised to (1) establish and maintain a falls team to create a culture focused on the reduction of falls risk; (2) teach staff to assess residents using the Morse Falls Scale to increase their awareness of residents' falls risk and improvement; and (3) modify existing exercise programs to address balance and lower body strength. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Uncertainty result of biotic index in analysing the water quality of Cikapundung river catchment area, Bandung

    NASA Astrophysics Data System (ADS)

    Surtikanti, Hertien Koosbandiah

    2017-05-01

    The Biotic Index was developed in Western Countries in response to the need in water quality evaluation. This method analysis is based on the classification of aquatic macrobenthos as a bioindicator for clean and polluted water. The aim of this study is to compare the analysis of Cikapundung river using 6 different Biotic Indexes. BI Shannon-Weiner, Belgian Biological Index (BBI), Family Biotic Index (FBI), Biological Monitoring Working Party (BMWP), Biological Monitoring Working Party-Average Score Per Taxon (BMWP-ASPT), and A Scoring System for Macroinvertebrate in Australian River (A SIGNAL). Those analysis are compared with Physical Water Index (CPI) which is developed in Indonesia. The result shows that a decreasing water quality is detected upstream to downstream of Cikapundung River. However, based on the CPI analysis result, the BMWP-ASPT biotic index analysis is more comprehensive than other BI in explaining Cikapundung water quality.

  15. Vestibular schwannomas: clinical results and quality of life after microsurgery or gamma knife radiosurgery.

    PubMed

    Myrseth, Erling; Møller, Per; Pedersen, Paal-Henning; Vassbotn, Flemming S; Wentzel-Larsen, Tore; Lund-Johansen, Morten

    2005-05-01

    The aim of the present study was to evaluate the overall treatment efficacy (tumor control, facial nerve function, complications) and quality of life for patients treated primarily for unilateral vestibular schwannomas of 30 mm or less, either by microsurgery or by gamma knife (GK) radiosurgery. The results for the two treatment groups are compared with each other, with main emphasis on the long-term quality of life. This is a retrospective study of 189 consecutive patients, 86 treated by microsurgery and 103 by gamma knife. The mean observation time was 5.9 years. All patients had a magnetic resonance imaging scan and clinical evaluation performed toward the end of the study. To evaluate the quality of life, we used two standardized questionnaires, the Glasgow Benefit Inventory and Short-Form 36. The questionnaires were sent to the 168 living patients. The reply rate was 83.3%. A total of 79.8% of the patients in the microsurgery group and 94.8% of the GK patients had a good facial nerve function (House-Brackmann Grade 1-2). Hearing was usually lost after microsurgery, whereas the GK patients had preserved hearing, which often became reduced over the years after the treatment. The treatment efficacy, defined as no need for additional treatment, was similar for the two treatment modalities. Quality of life was reduced compared with normative data, being most reduced in the microsurgery group. Some of the quality of life questions showed an association with facial nerve function and sex. Posttreatment facial nerve function, hearing, complication rates, and quality of life were all significantly in favor of GK radiosurgery.

  16. Impacts of a Rural Subdivision on Groundwater Quality: Results of Long-Term Monitoring.

    PubMed

    Rayne, Todd W; Bradbury, Kenneth R; Krause, Jacob J

    2018-03-30

    A rural subdivision in south central Wisconsin was instrumented with monitoring wells and lysimeters before, during, and after its construction to examine the impacts of the unsewered subdivision on groundwater quality and quantity. Prior to construction, the 78-acre (32 ha) site was farmland. Sixteen homes were constructed beginning in 2003. Initial monitoring from 2002 to 2005 showed that groundwater beneath the site had been impacted by previous agricultural use, with nitrate-N values as high as 30 mg/L and some detections of the herbicide atrazine. Our 12-year study shows that the transition from agricultural to residential land use has changed groundwater quality in both negative and positive ways. Although groundwater elevations showed typical seasonal fluctuations each year, there were no measurable changes in groundwater levels or general flow directions during the 12-year study period. Chloride values increased in many wells, possibly as a result of road salting or water softener discharge. Nitrate concentrations varied spatially and temporally over the study period, with some initial concentrations substantially above the drinking water standard. In some wells, nitrate and atrazine levels have declined substantially since agriculture ceased. However, atrazine was still present at trace concentrations throughout the site in 2014. Wastewater tracers show there are small but detectable impacts from septic effluent on groundwater quality. Particle traces based on a groundwater flow model are consistent with the hypothesis that septic leachate has impacted groundwater quality. © 2018, National Ground Water Association.

  17. Chemical Composition and Antioxidant Properties of Powders Obtained from Different Plum Juice Formulations.

    PubMed

    Michalska, Anna; Wojdyło, Aneta; Łysiak, Grzegorz P; Figiel, Adam

    2017-01-17

    Among popular crops, plum ( Prunus domestica L.) has received special attention due to its health-promoting properties. The seasonality of this fruit makes it impossible to consume it throughout the year, so new products in a powder form may offer an alternative to fresh consumption and may be used as high-quality natural food ingredients. A 100% plum (cultivar "Valor") juice was mixed with three different concentrations of maltodextrin or subjected to sugars removal by amberlite-XAD column, and dried using the freeze, spray, and vacuum (40, 60, and 80 °C) drying techniques. The identification and quantification of phenolic acids, flavonols, and anthocyanins in plum powders was performed by LC-MS QTof and UPLC-PDA, respectively. l-ascorbic acid, hydroxymethylfurfural, and antioxidant capacity were measured by the Trolox equivalent antioxidant capacity (TEAC) ABTS and ferric reducing antioxidant potential (FRAP) methods in order to compare the influence of the drying methods on product quality. The results indicated that the profile of polyphenolic compounds in the plum juice powders significantly differed from the whole plum powders. The drying of a sugar free plum extract resulted in higher content of polyphenolic compounds, l-ascorbic acid and antioxidant capacity, but lower content of hydroxymethylfurfural, regardless of drying method applied. Thus, the formulation of plum juice before drying and the drying method should be carefully selected in order to obtain high-quality powders.

  18. Effect of sleep deficit, knowledge of results, and stimulus quality on reaction time and response force.

    PubMed

    Jaśkowski, P; Włodarczyk, D

    1997-04-01

    Some recent findings suggested that response force measured during reaction time experiments might reflect changes in activation. We performed an experiment in which the effect of sleep deprivation, knowledge of results, and stimulus quality on response force was studied in simple and choice reaction tasks. As expected, both simple and choice reaction times increased with sleep deficit. Further, simple and choice reactions were faster with knowledge of results and slowed down when stimulus quality was degraded. As sleep deprivation affects both arousal and activation, we expected a detrimental effect of sleep on force amplitude. On the other hand, knowledge of results was expected to increase force by its compensatory effect on arousal and activation. No effect of sleep deprivation on response force was found. Knowledge of results increased response force independently of sleep deprivation.

  19. Evaluation of the Correlation Coefficient of Polyethylene Glycol Treated and Direct Prolactin Results and Comparability with Different Assay System Results.

    PubMed

    Pal, Shyamali

    2017-12-01

    The presence of Macro prolactin is a significant cause of elevated prolactin resulting in misdiagnosis in all automated systems. Poly ethylene glycol (PEG) pretreatment is the preventive process but such process includes the probability of loss of a fraction of bioactive prolactin. Surprisingly, PEG treated EQAS & IQAS samples in Cobas e 411 are found out to be correlating with direct results of at least 3 immunoassay systems and treated and untreated Cobas e 411 results are comparable by a correlation coefficient. Comparison of EQAS, IQAS and patient samples were done to find out the trueness of such correlation factor. Study with patient's results have established the correlation coefficient is valid for very small concentration of prolactin also. EQAS, IQAS and 150 patient samples were treated with PEG and prolactin results of treated and untreated samples obtained from Roche Cobas e 411. 25 patient's results (treated) were compared with direct results in Advia Centaur, Architect I & Access2 systems. Correlation coefficient was obtained from trend line of the treated and untreated results. Two tailed p-value obtained from regression coefficient(r) and sample size. The correlation coefficient is in the range (0.761-0.771). Reverse correlation range is (1.289-1.301). r value of two sets of calculated results were 0.995. Two tailed p- value is zero approving dismissal of null hypothesis. The z-score of EQAS does not always assure authenticity of resultsPEG precipitation is correlated by the factor 0.761 even in very small concentrationsAbbreviationsGFCgel filtration chromatographyPEGpolyethylene glycolEQASexternal quality assurance systemM-PRLmacro prolactinPRLprolactinECLIAelectro-chemiluminescence immunoassayCLIAclinical laboratory improvement amendmentsIQASinternal quality assurance systemrregression coefficient.

  20. RAPIDLY MEASURED INDICATORS OF RECREATIONAL WATER QUALITY ARE PREDICTIVE OF SWIMMING ASSOCIATED GASTROINTESTINAL ILLNESS

    EPA Science Inventory

    Standard methods to measure recreational water quality require at least 24 hours to obtain results making it impossible to assess the quality of water within a single day. Methods to measure recreational water quality in two hours or less have been developed. Application of rapid...

  1. Cost-effectiveness of a combined physical exercise and psychosocial training intervention for children with cancer: Results from the quality of life in motion study.

    PubMed

    Braam, K I; van Dijk-Lokkart, E M; van Dongen, J M; van Litsenburg, R R L; Takken, T; Huisman, J; Merks, J H M; Bosmans, J E; Hakkenbrak, N A G; Bierings, M B; van den Heuvel-Eibrink, M M; Veening, M A; van Dulmen-den Broeder, E; Kaspers, G J L

    2017-11-01

    This study was performed to estimate the cost-effectiveness of a combined physical exercise and psychosocial intervention for children with cancer compared with usual care. Sixty-eight children, aged 8-18 years old, during or within the first year post-cancer treatment were randomised to the intervention (n = 30) and control group (n = 38). Health outcomes included fitness, muscle strength and quality adjusted life years; all administered at baseline, 4- and 12-month follow-up. Costs were gathered by 1 monthly cost questionnaires over 12 months, supplemented by medication data obtained from pharmacies. Results showed no significant differences in costs and effects between the intervention and control group at 12-month follow-up. On average, societal costs were €299 higher in the intervention group than in the control group, but this difference was not significant. Cost-effectiveness acceptability curves indicated that the intervention needs large societal investments to reach reasonable probabilities of cost-effectiveness for quality of life and lower body muscle strength. Based on the results of this study, the intervention is not cost-effective in comparison with usual care. © 2016 John Wiley & Sons Ltd.

  2. Standardization of a fluconazole bioassay and correlation of results with those obtained by high-pressure liquid chromatography.

    PubMed Central

    Rex, J H; Hanson, L H; Amantea, M A; Stevens, D A; Bennett, J E

    1991-01-01

    An improved bioassay for fluconazole was developed. This assay is sensitive in the clinically relevant range (2 to 40 micrograms/ml) and analyzes plasma, serum, and cerebrospinal fluid specimens; bioassay results correlate with results obtained by high-pressure liquid chromatography (HPLC). Bioassay and HPLC analyses of spiked plasma, serum, and cerebrospinal fluid samples (run as unknowns) gave good agreement with expected values. Analysis of specimens from patients gave equivalent results by both HPLC and bioassay. HPLC had a lower within-run coefficient of variation (less than 2.5% for HPLC versus less than 11% for bioassay) and a lower between-run coefficient of variation (less than 5% versus less than 12% for bioassay) and was more sensitive (lower limit of detection, 0.1 micrograms/ml [versus 2 micrograms/ml for bioassay]). The bioassay is, however, sufficiently accurate and sensitive for clinical specimens, and its relative simplicity, low sample volume requirement, and low equipment cost should make it the technique of choice for analysis of routine clinical specimens. PMID:1854166

  3. [Inter-and intra-operator variability in the analysis of semen parameters: results from a quality control program].

    PubMed

    Daoud, Salima; Chakroun-Feki, Nozha; Sellami, Afifa; Ammar-Keskes, Leila; Rebai, Tarek

    2016-01-01

    Semen analysis is a key part of male infertility investigation. The necessity of quality management implementation in the andrology laboratory has been recognized in order to ensure the reliability of its results. The aim of this study was to evaluate intra- and inter-individual variability in the assessment of semen parameters in our laboratory through a quality control programme. Four participants from the laboratory with different experience levels have participated in this study. Semen samples of varying quality were assessed for sperm motility, concentration and morphology and the results were used to evaluate inter-participant variability. In addition, replicates of each semen sample were analyzed to determine intra-individual variability for semen parameters analysis. The average values of inter-participant coefficients of variation for sperm motility, concentration and morphology were 12.8%, 19.8% and 48.9% respectively. The mean intra-participant coefficients of variation were, respectively, 6.9%, 12.3% and 42.7% for sperm motility, concentration and morphology. Despite some random errors of under- or overestimation, the overall results remained within the limits of acceptability for all participants. Sperm morphology assessment was particularly influenced by the participant's level of experience. The present data emphasize the need for appropriate training of the laboratory staff and for regular participation in internal quality control programmes in order to improve the reliability of laboratory results.

  4. FQC Dashboard: integrates FastQC results into a web-based, interactive, and extensible FASTQ quality control tool

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Joseph; Pirrung, Meg; McCue, Lee Ann

    FQC is software that facilitates large-scale quality control of FASTQ files by carrying out a QC protocol, parsing results, and aggregating quality metrics within and across experiments into an interactive dashboard. The dashboard utilizes human-readable configuration files to manipulate the pages and tabs, and is extensible with CSV data.

  5. Influence of pansharpening techniques in obtaining accurate vegetation thematic maps

    NASA Astrophysics Data System (ADS)

    Ibarrola-Ulzurrun, Edurne; Gonzalo-Martin, Consuelo; Marcello-Ruiz, Javier

    2016-10-01

    In last decades, there have been a decline in natural resources, becoming important to develop reliable methodologies for their management. The appearance of very high resolution sensors has offered a practical and cost-effective means for a good environmental management. In this context, improvements are needed for obtaining higher quality of the information available in order to get reliable classified images. Thus, pansharpening enhances the spatial resolution of the multispectral band by incorporating information from the panchromatic image. The main goal in the study is to implement pixel and object-based classification techniques applied to the fused imagery using different pansharpening algorithms and the evaluation of thematic maps generated that serve to obtain accurate information for the conservation of natural resources. A vulnerable heterogenic ecosystem from Canary Islands (Spain) was chosen, Teide National Park, and Worldview-2 high resolution imagery was employed. The classes considered of interest were set by the National Park conservation managers. 7 pansharpening techniques (GS, FIHS, HCS, MTF based, Wavelet `à trous' and Weighted Wavelet `à trous' through Fractal Dimension Maps) were chosen in order to improve the data quality with the goal to analyze the vegetation classes. Next, different classification algorithms were applied at pixel-based and object-based approach, moreover, an accuracy assessment of the different thematic maps obtained were performed. The highest classification accuracy was obtained applying Support Vector Machine classifier at object-based approach in the Weighted Wavelet `à trous' through Fractal Dimension Maps fused image. Finally, highlight the difficulty of the classification in Teide ecosystem due to the heterogeneity and the small size of the species. Thus, it is important to obtain accurate thematic maps for further studies in the management and conservation of natural resources.

  6. [ISO 9001:2015 Certification in Quality Management].

    PubMed

    Enders, Christian; Lang, Gabriele E; Lang, Gerhard K; Werner, Jens Ulrich

    2017-07-01

    Quality management improves the structures, processes and results of organizations of all kinds. Many practices and clinics have their existing quality management system certified according to ISO 9001, (e.g., to check their own quality management system or to obtain a testimonial against third parties). The latest version ISO 9001:2015 contains some changes, both structurally and in terms of content. These changes can be met with reasonable efforts. An ISO 9001:2015 certification represents a value for your organization, but these advantages are often not directly measurable. Georg Thieme Verlag KG Stuttgart · New York.

  7. [Quality analyses of the development of preterm infants: results of the Lower-Saxonian preterm infant follow-up project and a comparison group of term infants].

    PubMed

    Damm, Gabriele; Macha, Thorsten; Petermann, Franz; Voss, Wolfgang; Sens, Brigitte

    2015-01-01

    Based on perinatal and neonatal quality assurance programmes, a follow-up project for the high-risk group of extremely preterm infants, unparalleled in Germany, was initiated in the federal state of Lower Saxony in 2004. Here we describe the new approach of examining a comparison group of term infants, which, for the first time, allows a valid interpretation of the collection of area-wide long-term outcome data on preterm children. The prospective long-term outcome project investigates the medical care situation for children born at less than 28 weeks of gestation up to school age. Based on the information obtained about the children's development the quality of health care will be optimised. A standardised examining concept with established development tests at defined follow-up intervals (at the age of 6 months, 2, 5 and 10 years) is used. At the age of five years 75 % of the examined premature children exhibited impairments. In order to better assess remarkable results, a comparison group of term infants (n=305) selected by a matched-pairs method was examined at the age of five using an analogous concept in kindergartens in Lower Saxony. The results were compared with the first two age cohorts of the follow-up-project (n=226) and quality analyses performed. As expected, significant differences have been found in the children's motor, cognitive and linguistic development between the preterm and term infants examined. This fact draws attention to the importance of early support for the majority of extremely premature infants. Feedback on the results given to the medical staff involved allows for the implementation of best practices and quality improvements. Identifying potential for improvement in everyday health care will help to develop specific optimisation measures. Copyright © 2015. Published by Elsevier GmbH.

  8. Measuring the willingness to pay for drinking water quality improvements: results of a contingent valuation survey in Songzi, China.

    PubMed

    Jianjun, Jin; Wenyu, Wang; Ying, Fan; Xiaomin, Wang

    2016-06-01

    The aim of this study is to elicit local residents' willingness to pay (WTP), by applying the contingent valuation method as a surcharge on their water bill, for a given improvement in the drinking water quality and the supply reliability. The mean WTP for the drinking water quality improvement program was estimated to be 16.71 yuan (0.3% of total household income). The results note that more educated respondents and households with higher income and with fewer household members are, on average, willing to pay more. This study also demonstrates that respondents' concerns regarding drinking water quality and perceptions of the health risk of drinking water quality can have significant positive impacts on people's WTP. The research results can help decision-makers understand the local population's demand for improved drinking water quality and undertake an environmental cost-benefit analysis.

  9. Results from the Big Spring basin water quality monitoring and demonstration projects, Iowa, USA

    USGS Publications Warehouse

    Rowden, R.D.; Liu, H.; Libra, R.D.

    2001-01-01

    Agricultural practices, hydrology, and water quality of the 267-km2 Big Spring groundwater drainage basin in Clayton County, Iowa, have been monitored since 1981. Land use is agricultural; nitrate-nitrogen (-N) and herbicides are the resulting contaminants in groundwater and surface water. Ordovician Galena Group carbonate rocks comprise the main aquifer in the basin. Recharge to this karstic aquifer is by infiltration, augmented by sinkhole-captured runoff. Groundwater is discharged at Big Spring, where quantity and quality of the discharge are monitored. Monitoring has shown a threefold increase in groundwater nitrate-N concentrations from the 1960s to the early 1980s. The nitrate-N discharged from the basin typically is equivalent to over one-third of the nitrogen fertilizer applied, with larger losses during wetter years. Atrazine is present in groundwater all year; however, contaminant concentrations in the groundwater respond directly to recharge events, and unique chemical signatures of infiltration versus runoff recharge are detectable in the discharge from Big Spring. Education and demonstration efforts have reduced nitrogen fertilizer application rates by one-third since 1981. Relating declines in nitrate and pesticide concentrations to inputs of nitrogen fertilizer and pesticides at Big Spring is problematic. Annual recharge has varied five-fold during monitoring, overshadowing any water-quality improvements resulting from incrementally decreased inputs. ?? Springer-Verlag 2001.

  10. The quality of health care in prison: results of a year's programme of semistructured inspections.

    PubMed Central

    Reed, J.; Lyne, M.

    1997-01-01

    OBJECTIVES: To assess, as part of wider inspections by HM Inspectorate of Prisons, the extent and quality of health care in prisons in England and Wales. DESIGN: Inspections based on a set of "expectations" derived mainly from existing healthcare quality standards published by the prison service and existing ethical guidelines; questionnaire survey of prisoners. SUBJECTS: 19 prisons in England and Wales, 1996-7. MAIN OUTCOME MEASURES: Appraisals of needs assessment and the commissioning and delivery of health care against the inspectorate's expectations. RESULTS: The quality of health care varied greatly. A few prisons provided health care broadly equivalent to NHS care, but in many the health care was of low quality, some doctors were not adequately trained to do the work they faced, and some care failed to meet proper ethical standards. Little professional support was available to healthcare staff. CONCLUSIONS: The current policy for improving health care in prisons is not likely to achieve its objectives and is potentially wasteful. The prison service needs to recognise that expertise in the commissioning and delivery of health care is overwhelming based in the NHS. The current review of the provision of health care in prisons offers an opportunity to ensure that prisoners are not excluded from high quality health care. PMID:9418090

  11. Image quality evaluation of full reference algorithm

    NASA Astrophysics Data System (ADS)

    He, Nannan; Xie, Kai; Li, Tong; Ye, Yushan

    2018-03-01

    Image quality evaluation is a classic research topic, the goal is to design the algorithm, given the subjective feelings consistent with the evaluation value. This paper mainly introduces several typical reference methods of Mean Squared Error(MSE), Peak Signal to Noise Rate(PSNR), Structural Similarity Image Metric(SSIM) and feature similarity(FSIM) of objective evaluation methods. The different evaluation methods are tested by Matlab, and the advantages and disadvantages of these methods are obtained by analyzing and comparing them.MSE and PSNR are simple, but they are not considered to introduce HVS characteristics into image quality evaluation. The evaluation result is not ideal. SSIM has a good correlation and simple calculation ,because it is considered to the human visual effect into image quality evaluation,However the SSIM method is based on a hypothesis,The evaluation result is limited. The FSIM method can be used for test of gray image and color image test, and the result is better. Experimental results show that the new image quality evaluation algorithm based on FSIM is more accurate.

  12. Effect of Total Quality Management on the Quality and Productivity of Human Resources

    NASA Astrophysics Data System (ADS)

    Siregar, I.; Nasution, A. A.; Sari, R. M.

    2017-03-01

    Human resources is the main factor in improving company performance not only in industrial products but also services. Therefore, all of the organization performers involved must work together to achieve product quality services expected by consumers. Educational institutions are the service industries which are educators and instructor involved in it. Quality of product and services produced depends on the education organization performers. This study did a survey of instructors in public and private universities in North Sumatra to obtain the factors that affect quality of human resources and productivity of human resources. Human resources quality is viewed by the elements of TQM. TQM elements that are discussed in this study are leadership, communication, training and education, support structure, measurement and reward and recognition. The results of this study showed a correlation numbers across the exogenous variables on endogenous variables relationships tend to be strong and be positive. In addition, elements of TQM are discussed except the support structure which has a direct influence on the quality of human resources. Variable leadership, reward and recognition and quality of human resources have a significant effect on productivity.

  13. Multi-Grid detector for neutron spectroscopy: results obtained on time-of-flight spectrometer CNCS

    NASA Astrophysics Data System (ADS)

    Anastasopoulos, M.; Bebb, R.; Berry, K.; Birch, J.; Bryś, T.; Buffet, J.-C.; Clergeau, J.-F.; Deen, P. P.; Ehlers, G.; van Esch, P.; Everett, S. M.; Guerard, B.; Hall-Wilton, R.; Herwig, K.; Hultman, L.; Höglund, C.; Iruretagoiena, I.; Issa, F.; Jensen, J.; Khaplanov, A.; Kirstein, O.; Lopez Higuera, I.; Piscitelli, F.; Robinson, L.; Schmidt, S.; Stefanescu, I.

    2017-04-01

    The Multi-Grid detector technology has evolved from the proof-of-principle and characterisation stages. Here we report on the performance of the Multi-Grid detector, the MG.CNCS prototype, which has been installed and tested at the Cold Neutron Chopper Spectrometer, CNCS at SNS. This has allowed a side-by-side comparison to the performance of 3He detectors on an operational instrument. The demonstrator has an active area of 0.2 m2. It is specifically tailored to the specifications of CNCS. The detector was installed in June 2016 and has operated since then, collecting neutron scattering data in parallel to the He-3 detectors of CNCS. In this paper, we present a comprehensive analysis of this data, in particular on instrument energy resolution, rate capability, background and relative efficiency. Stability, gamma-ray and fast neutron sensitivity have also been investigated. The effect of scattering in the detector components has been measured and provides input to comparison for Monte Carlo simulations. All data is presented in comparison to that measured by the 3He detectors simultaneously, showing that all features recorded by one detector are also recorded by the other. The energy resolution matches closely. We find that the Multi-Grid is able to match the data collected by 3He, and see an indication of a considerable advantage in the count rate capability. Based on these results, we are confident that the Multi-Grid detector will be capable of producing high quality scientific data on chopper spectrometers utilising the unprecedented neutron flux of the ESS.

  14. Sci-Thur PM: YIS - 07: Monte Carlo simulations to obtain several parameters required for electron beam dosimetry.

    PubMed

    Muir, B; Rogers, D; McEwen, M

    2012-07-01

    When current dosimetry protocols were written, electron beam data were limited and had uncertainties that were unacceptable for reference dosimetry. Protocols for high-energy reference dosimetry are currently being updated leading to considerable interest in accurate electron beam data. To this end, Monte Carlo simulations using the EGSnrc user-code egs_chamber are performed to extract relevant data for reference beam dosimetry. Calculations of the absorbed dose to water and the absorbed dose to the gas in realistic ion chamber models are performed as a function of depth in water for cobalt-60 and high-energy electron beams between 4 and 22 MeV. These calculations are used to extract several of the parameters required for electron beam dosimetry - the beam quality specifier, R 50 , beam quality conversion factors, k Q and k R50 , the electron quality conversion factor, k' R50 , the photon-electron conversion factor, k ecal , and ion chamber perturbation factors, P Q . The method used has the advantage that many important parameters can be extracted as a function of depth instead of determination at only the reference depth as has typically been done. Results obtained here are in good agreement with measured and other calculated results. The photon-electron conversion factors obtained for a Farmer-type NE2571 and plane-parallel PTW Roos, IBA NACP-02 and Exradin A11 chambers are 0.903, 0.896, 0.894 and 0.906, respectively. These typically differ by less than 0.7% from the contentious TG-51 values but have much smaller systematic uncertainties. These results are valuable for reference dosimetry of high-energy electron beams. © 2012 American Association of Physicists in Medicine.

  15. The quality of radiation care: the results of focus group interviews and concept mapping to explore the patient's perspective.

    PubMed

    Nijman, Jessica L; Sixma, Herman; van Triest, Baukelien; Keus, Ronald B; Hendriks, Michelle

    2012-01-01

    In this study, we explore the quality aspects of radiation care from the patient's perspective in order to develop a draft Consumer Quality Index (CQI) Radiation Care instrument. Four focus group discussions with (former) cancer patients were held to explore the aspects determining the quality of radiation care. The list of aspects generated was categorised based on similarity and importance in a concept mapping procedure. Four focus group discussions revealed seven main themes related to the quality of radiation care: information provision, a patient-centred approach, professional competence, planning and waiting times, accessibility, cooperation and communication, and follow-up care. Results of concept mapping procedures revealed which items the patients considered to be most important. A radiation oncologist who is up to date about the patient's file is of paramount importance for cancer patients receiving radiotherapy. The quality aspects found through focus group discussions provided useful insight into how patients experience radiation care. Furthermore, concept mapping made these results more solid. To evaluate the quality of radiation care from the patient's perspective, these quality aspects will be guiding in the development of a CQI Radiation Care. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  16. Virtual Guidance Ultrasound: A Tool to Obtain Diagnostic Ultrasound for Remote Environments

    NASA Technical Reports Server (NTRS)

    Caine,Timothy L.; Martin David S.; Matz, Timothy; Lee, Stuart M. C.; Stenger, Michael B.; Platts, Steven H.

    2012-01-01

    Astronauts currently acquire ultrasound images on the International Space Station with the assistance of real-time remote guidance from an ultrasound expert in Mission Control. Remote guidance will not be feasible when significant communication delays exist during exploration missions beyond low-Earth orbit. For example, there may be as much as a 20- minute delay in communications between the Earth and Mars. Virtual-guidance, a pre-recorded audio-visual tutorial viewed in real-time, is a viable modality for minimally trained scanners to obtain diagnostically-adequate images of clinically relevant anatomical structures in an autonomous manner. METHODS: Inexperienced ultrasound operators were recruited to perform carotid artery (n = 10) and ophthalmic (n = 9) ultrasound examinations using virtual guidance as their only instructional tool. In the carotid group, each each untrained operator acquired two-dimensional, pulsed, and color Doppler of the carotid artery. In the ophthalmic group, operators acquired representative images of the anterior chamber of the eye, retina, optic nerve, and nerve sheath. Ultrasound image quality was evaluated by independent imaging experts. RESULTS: Eight of the 10 carotid studies were judged to be diagnostically adequate. With one exception the quality of all the ophthalmic images were adequate to excellent. CONCLUSION: Diagnostically-adequate carotid and ophthalmic ultrasound examinations can be obtained by untrained operators with instruction only from an audio/video tutorial viewed in real time while scanning. This form of quick-response-guidance, can be developed for other ultrasound examinations, represents an opportunity to acquire important medical and scientific information for NASA flight surgeons and researchers when trained medical personnel are not present. Further, virtual guidance will allow untrained personnel to autonomously obtain important medical information in remote locations on Earth where communication is

  17. Noise Estimation and Quality Assessment of Gaussian Noise Corrupted Images

    NASA Astrophysics Data System (ADS)

    Kamble, V. M.; Bhurchandi, K.

    2018-03-01

    Evaluating the exact quantity of noise present in an image and quality of an image in the absence of reference image is a challenging task. We propose a near perfect noise estimation method and a no reference image quality assessment method for images corrupted by Gaussian noise. The proposed methods obtain initial estimate of noise standard deviation present in an image using the median of wavelet transform coefficients and then obtains a near to exact estimate using curve fitting. The proposed noise estimation method provides the estimate of noise within average error of +/-4%. For quality assessment, this noise estimate is mapped to fit the Differential Mean Opinion Score (DMOS) using a nonlinear function. The proposed methods require minimum training and yields the noise estimate and image quality score. Images from Laboratory for image and Video Processing (LIVE) database and Computational Perception and Image Quality (CSIQ) database are used for validation of the proposed quality assessment method. Experimental results show that the performance of proposed quality assessment method is at par with the existing no reference image quality assessment metric for Gaussian noise corrupted images.

  18. Multi Objective Optimization of Yarn Quality and Fibre Quality Using Evolutionary Algorithm

    NASA Astrophysics Data System (ADS)

    Ghosh, Anindya; Das, Subhasis; Banerjee, Debamalya

    2013-03-01

    The quality and cost of resulting yarn play a significant role to determine its end application. The challenging task of any spinner lies in producing a good quality yarn with added cost benefit. The present work does a multi-objective optimization on two objectives, viz. maximization of cotton yarn strength and minimization of raw material quality. The first objective function has been formulated based on the artificial neural network input-output relation between cotton fibre properties and yarn strength. The second objective function is formulated with the well known regression equation of spinning consistency index. It is obvious that these two objectives are conflicting in nature i.e. not a single combination of cotton fibre parameters does exist which produce maximum yarn strength and minimum cotton fibre quality simultaneously. Therefore, it has several optimal solutions from which a trade-off is needed depending upon the requirement of user. In this work, the optimal solutions are obtained with an elitist multi-objective evolutionary algorithm based on Non-dominated Sorting Genetic Algorithm II (NSGA-II). These optimum solutions may lead to the efficient exploitation of raw materials to produce better quality yarns at low costs.

  19. 40 CFR 60.2170 - Is there a minimum amount of monitoring data I must obtain?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Is there a minimum amount of monitoring..., 2001 Monitoring § 60.2170 Is there a minimum amount of monitoring data I must obtain? (a) Except for monitor malfunctions, associated repairs, and required quality assurance or quality control activities...

  20. Aircraft and ground vehicle friction correlation test results obtained under winter runway conditions during joint FAA/NASA Runway Friction Program

    NASA Technical Reports Server (NTRS)

    Yager, Thomas J.; Vogler, William A.; Baldasare, Paul

    1988-01-01

    Aircraft and ground vehicle friction data collected during the Joint FAA/NASA Runway Friction Program under winter runway conditions are discussed and test results are summarized. The relationship between the different ground vehicle friction measurements obtained on compacted snow- and ice-covered conditions is defined together with the correlation to aircraft tire friction performance under similar runway conditions.

  1. Memory colours and colour quality evaluation of conventional and solid-state lamps.

    PubMed

    Smet, Kevin A G; Ryckaert, Wouter R; Pointer, Michael R; Deconinck, Geert; Hanselaer, Peter

    2010-12-06

    A colour quality metric based on memory colours is presented. The basic idea is simple. The colour quality of a test source is evaluated as the degree of similarity between the colour appearance of a set of familiar objects and their memory colours. The closer the match, the better the colour quality. This similarity was quantified using a set of similarity distributions obtained by Smet et al. in a previous study. The metric was validated by calculating the Pearson and Spearman correlation coefficients between the metric predictions and the visual appreciation results obtained in a validation experiment conducted by the authors as well those obtained in two independent studies. The metric was found to correlate well with the visual appreciation of the lighting quality of the sources used in the three experiments. Its performance was also compared with that of the CIE colour rendering index and the NIST colour quality scale. For all three experiments, the metric was found to be significantly better at predicting the correct visual rank order of the light sources (p < 0.1).

  2. Optimization of preservation and storage time of sponge tissues to obtain quality mRNA for next-generation sequencing.

    PubMed

    Riesgo, Ana; Pérez-Porro, Alicia R; Carmona, Susana; Leys, Sally P; Giribet, Gonzalo

    2012-03-01

    Transcriptome sequencing with next-generation sequencing technologies has the potential for addressing many long-standing questions about the biology of sponges. Transcriptome sequence quality depends on good cDNA libraries, which requires high-quality mRNA. Standard protocols for preserving and isolating mRNA often require optimization for unusual tissue types. Our aim was assessing the efficiency of two preservation modes, (i) flash freezing with liquid nitrogen (LN₂) and (ii) immersion in RNAlater, for the recovery of high-quality mRNA from sponge tissues. We also tested whether the long-term storage of samples at -80 °C affects the quantity and quality of mRNA. We extracted mRNA from nine sponge species and analysed the quantity and quality (A260/230 and A260/280 ratios) of mRNA according to preservation method, storage time, and taxonomy. The quantity and quality of mRNA depended significantly on the preservation method used (LN₂) outperforming RNAlater), the sponge species, and the interaction between them. When the preservation was analysed in combination with either storage time or species, the quantity and A260/230 ratio were both significantly higher for LN₂-preserved samples. Interestingly, individual comparisons for each preservation method over time indicated that both methods performed equally efficiently during the first month, but RNAlater lost efficiency in storage times longer than 2 months compared with flash-frozen samples. In summary, we find that for long-term preservation of samples, flash freezing is the preferred method. If LN₂ is not available, RNAlater can be used, but mRNA extraction during the first month of storage is advised. © 2011 Blackwell Publishing Ltd.

  3. Lean practices for quality results: a case illustration.

    PubMed

    Hwang, Pauline; Hwang, David; Hong, Paul

    2014-01-01

    Increasingly, healthcare providers are implementing lean practices to achieve quality results. Implementing lean healthcare practices is unique compared to manufacturing and other service industries. The purpose of this paper is to present a model that identifies and defines the lean implementation key success factors in healthcare organisations. The model is based on an extant literature review and a case illustration that explores actual lean implementation in a major USA hospital located in a Midwestern city (approximately 300,000 people). An exploratory/descriptive study using observation and follow-up interviews was conducted to identify lean practices in the hospital. Lean practice key drivers include growing elderly populations, rising medical expenses, decreasing insurance coverage and decreasing management support. Effectively implementing lean practices to increase bottom-line results and improve organisational integrity requires sharing goals and processes among healthcare managers and professionals. An illustration explains the model and the study provides a sound foundation for empirical work. Practical implications are included. Lean practices minimise waste and unnecessary hospital stays while simultaneously enhancing customer values and deploying resources in supply systems. Leadership requires clear project targets based on sound front-end planning because initial implementation steps involve uncertainty and ambiguity (i.e. fuzzy front-end planning). Since top management support is crucial for implementing lean practices successfully, a heavyweight manager, who communicates well both with top managers and project team members, is an important success factor when implementing lean practices. Increasingly, green orientation and sustainability initiatives are phrases that replaced lean practices. Effective results; e.g. waste reduction, employee satisfaction and customer values are applicable to bigger competitive challenges arising both in specific

  4. Results from CrIS/ATMS Obtained Using an "AIRS Version-6 Like" Retrieval Algorithm

    NASA Technical Reports Server (NTRS)

    Susskind, Joel; Kouvaris, Louis; Iredell, Lena

    2015-01-01

    A main objective of AIRS/AMSU on EOS is to provide accurate sounding products that are used to generate climate data sets. Suomi NPP carries CrIS/ATMS that were designed as follow-ons to AIRS/AMSU. Our objective is to generate a long term climate data set of products derived from CrIS/ATMS to serve as a continuation of the AIRS/AMSU products. We have modified an improved version of the operational AIRS Version-6 retrieval algorithm for use with CrIS/ATMS. CrIS/ATMS products are of very good quality, and are comparable to, and consistent with, those of AIRS.

  5. Patterned growth of carbon nanotubes obtained by high density plasma chemical vapor deposition

    NASA Astrophysics Data System (ADS)

    Mousinho, A. P.; Mansano, R. D.

    2015-03-01

    Patterned growth of carbon nanotubes by chemical vapor deposition represents an assembly approach to place and orient nanotubes at a stage as early as when they are synthesized. In this work, the carbon nanotubes were obtained at room temperature by High Density Plasmas Chemical Vapor Deposition (HDPCVD) system. This CVD system uses a new concept of plasma generation, where a planar coil coupled to an RF system for plasma generation was used with an electrostatic shield for plasma densification. In this mode, high density plasmas are obtained. We also report the patterned growth of carbon nanotubes on full 4-in Si wafers, using pure methane plasmas and iron as precursor material (seed). Photolithography processes were used to pattern the regions on the silicon wafers. The carbon nanotubes were characterized by micro-Raman spectroscopy, the spectra showed very single-walled carbon nanotubes axial vibration modes around 1590 cm-1 and radial breathing modes (RBM) around 120-400 cm-1, confirming that high quality of the carbon nanotubes obtained in this work. The carbon nanotubes were analyzed by atomic force microscopy and scanning electron microscopy too. The results showed that is possible obtain high-aligned carbon nanotubes with patterned growth on a silicon wafer with high reproducibility and control.

  6. Quality comparison of websites related to developmental disabilities.

    PubMed

    Reichow, Brian; Shefcyk, Allison; Bruder, Mary Beth

    2013-10-01

    The Internet is commonly used to seek health-related information, but little is known about the quality of websites on developmental disabilities. Therefore, we sought to evaluate the characteristics and quality of websites located by searching ten common terms related to developmental disabilities and explore relations between website characteristics and website quality in order to make recommendations on ways to ensure locating good online information. We located 208 unique websites in our November 2012 US searches of Google and Bing. Two independent coders evaluated 10 characteristics of the websites and two different coders assessed the quality of the websites. From the 208 websites, 104 (50%) provided relevant information about the disability being searched. Of these 104 websites, those found to be of highest quality were least likely to be a sponsored result, contain advertisements, be from a for-profit company, and did contain references to peer-reviewed publications or had a top-level domain of .gov or .org. Individuals with developmental disabilities and their family members who choose to obtain disability-related information online should remain vigilant to ensure that they locate high-quality and accurate information and should not replace information obtained from health-care professionals and educational specialists with information found online. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. On the need for quality assurance in superficial kilovoltage radiotherapy.

    PubMed

    Austerlitz, C; Mota, H; Gay, H; Campos, D; Allison, R; Sibata, C

    2008-01-01

    External auditing of beam output and energy qualities of four therapeutic X-ray machines were performed in three radiation oncology centres in northeastern Brazil. The output and half-value layers (HVLs) were determined using a parallel-plate ionisation chamber and high-purity aluminium foils, respectively. The obtained values of absorbed dose to water and energy qualities were compared with those obtained by the respective institutions. The impact on the prescribed dose was analysed by determining the half-value depth (D(1/2)). The beam outputs presented percent differences ranging from -13 to +25%. The ratio between the HVL in use by the institution and the measurements obtained in this study ranged from 0.75 to 2.33. Such deviations in HVL result in percent differences in dose at D(1/2) ranging from -52 to +8%. It was concluded that dosimetric quality audit programmes in radiation therapy should be expanded to include dermatological radiation therapy and such audits should include HVL verification.

  8. Quality initiatives: improving patient flow for a bone densitometry practice: results from a Mayo Clinic radiology quality initiative.

    PubMed

    Aakre, Kenneth T; Valley, Timothy B; O'Connor, Michael K

    2010-03-01

    Lean Six Sigma process improvement methodologies have been used in manufacturing for some time. However, Lean Six Sigma process improvement methodologies also are applicable to radiology as a way to identify opportunities for improvement in patient care delivery settings. A multidisciplinary team of physicians and staff conducted a 100-day quality improvement project with the guidance of a quality advisor. By using the framework of DMAIC (define, measure, analyze, improve, and control), time studies were performed for all aspects of patient and technologist involvement. From these studies, value stream maps for the current state and for the future were developed, and tests of change were implemented. Comprehensive value stream maps showed that before implementation of process changes, an average time of 20.95 minutes was required for completion of a bone densitometry study. Two process changes (ie, tests of change) were undertaken. First, the location for completion of a patient assessment form was moved from inside the imaging room to the waiting area, enabling patients to complete the form while waiting for the technologist. Second, the patient was instructed to sit in a waiting area immediately outside the imaging rooms, rather than in the main reception area, which is far removed from the imaging area. Realignment of these process steps, with reduced technologist travel distances, resulted in a 3-minute average decrease in the patient cycle time. This represented a 15% reduction in the initial patient cycle time with no change in staff or costs. Radiology process improvement projects can yield positive results despite small incremental changes.

  9. A comparison of data obtained from service providers and service users to assess the quality of maternity care.

    PubMed

    Hundley, V; Penney, G; Fitzmaurice, A; van Teijlingen, E; Graham, W

    2002-06-01

    to compare data obtained from two sources, service providers and service users, regarding the maternity services in Scotland. an audit of maternity services involving site visits, staff interviews and a cross-sectional survey of service users. lead professionals in every consultant-led maternity unit in Scotland and all 1639 women giving birth in Scotland during a ten-day period. structured group interviews with service providers and a questionnaire survey of recently delivered women. professionals' and women's responses were cross-tabulated and differences in proportions were tested for statistical significance using the chi-square test. a total of 1137 women completed the questionnaire (response rate 69%). Overall, there was good agreement between professionals' and women's perceptions of the aspects of care studied. However, there were disparities in some areas. For example, staff in eight units reported mechanisms to ensure early distribution of a free national pregnancy book; however, in six of these units less than 75% of women actually received this book prior to their first hospital visit. Eighteen units reported that they offer a postnatal 'reunion meeting'; in ten of these units, less than 50% of women were aware of the reunion meeting. Eighteen units reported a policy of each woman having a lead professional or care co-ordinator; in three of these units, less than 50% of women perceived that they had a care co-ordinator and for most women, the profession (midwife, general practitioner or obstetrician) of their perceived co-ordinator differed from that expected on the basis of staff reports. There was some evidence overall that unit policies had a direct influence on women's responses. this study demonstrates the importance of using a range of complementary methods of data collection and of ascertaining both service users' and providers' views when assessing the quality of care. Further research is required to explore differences in service provider's and

  10. The LANDSAT system operated in Brazil by CNPq/INPE - results obtained in the area of mapping and future perspectives

    NASA Technical Reports Server (NTRS)

    Dejesusparada, N. (Principal Investigator); Barbosa, M. N.

    1981-01-01

    The LANDSAT system, operated in the country by CNPg/INPE since 1973, systematically acquires, produces, and distributes both multispectral and panchromatic images obtained through remote sensing satellites to thousands of researchers and technicians involved in the natural resources survey. To cooperate in the solution of national problems, CNPq/INPE is developing efforts in the area of manipulation of those images with the objective of making them useful as planimetric bases for the simple revision of already published maps or for its utilization as basic material in regions not yet reliability mapped. The results obtained from performed tests are presented and the existing limitations are discussed. The new system purchased to handle data from the next series of LANDSAT as well as from MAPSAT and SPOT which will be in operation within the 80's decade, and are designed not only for natural resources survey but also for the solution of cartographic problems.

  11. Design, implementation, and initial results from a water-quality monitoring network for Atlanta, Georgia, USA

    USGS Publications Warehouse

    Horowitz, A.J.; Elrick, K.A.; Smith, J.J.

    2005-01-01

    In cooperation with the City of Atlanta, Georgia, the US Geological Survey has designed and implemented a water-quantity and quality monitoring network that measures a variety of biological and chemical constituents in water and suspended sediment. The network consists of 20 long-term monitoring sites and is intended to assess water-quality trends in response to planned infrastructural improvements. Initial results from the network indicate that nonpoint-source contributions may be more significant than point-source contributions for selected sediment associated trace elements and nutrients. There also are indications of short-term discontinuous point-source contributions of these same constituents during baseflow.

  12. Chemical Composition and Antioxidant Properties of Powders Obtained from Different Plum Juice Formulations

    PubMed Central

    Michalska, Anna; Wojdyło, Aneta; Łysiak, Grzegorz P.; Figiel, Adam

    2017-01-01

    Among popular crops, plum (Prunus domestica L.) has received special attention due to its health-promoting properties. The seasonality of this fruit makes it impossible to consume it throughout the year, so new products in a powder form may offer an alternative to fresh consumption and may be used as high-quality natural food ingredients. A 100% plum (cultivar “Valor”) juice was mixed with three different concentrations of maltodextrin or subjected to sugars removal by amberlite-XAD column, and dried using the freeze, spray, and vacuum (40, 60, and 80 °C) drying techniques. The identification and quantification of phenolic acids, flavonols, and anthocyanins in plum powders was performed by LC-MS QTof and UPLC-PDA, respectively. l-ascorbic acid, hydroxymethylfurfural, and antioxidant capacity were measured by the Trolox equivalent antioxidant capacity (TEAC) ABTS and ferric reducing antioxidant potential (FRAP) methods in order to compare the influence of the drying methods on product quality. The results indicated that the profile of polyphenolic compounds in the plum juice powders significantly differed from the whole plum powders. The drying of a sugar free plum extract resulted in higher content of polyphenolic compounds, l-ascorbic acid and antioxidant capacity, but lower content of hydroxymethylfurfural, regardless of drying method applied. Thus, the formulation of plum juice before drying and the drying method should be carefully selected in order to obtain high-quality powders. PMID:28106740

  13. Objectification of perceptual image quality for mobile video

    NASA Astrophysics Data System (ADS)

    Lee, Seon-Oh; Sim, Dong-Gyu

    2011-06-01

    This paper presents an objective video quality evaluation method for quantifying the subjective quality of digital mobile video. The proposed method aims to objectify the subjective quality by extracting edgeness and blockiness parameters. To evaluate the performance of the proposed algorithms, we carried out subjective video quality tests with the double-stimulus continuous quality scale method and obtained differential mean opinion score values for 120 mobile video clips. We then compared the performance of the proposed methods with that of existing methods in terms of the differential mean opinion score with 120 mobile video clips. Experimental results showed that the proposed methods were approximately 10% better than the edge peak signal-to-noise ratio of the J.247 method in terms of the Pearson correlation.

  14. [Analysis on 2011 quality control results on aerobic plate count of microbiology laboratories in China].

    PubMed

    Han, Haihong; Li, Ning; Li, Yepeng; Fu, Ping; Yu, Dongmin; Li Zhigang; Du, Chunming; Guo, Yunchang

    2015-01-01

    To test the aerobic plate count examining capability of microbiology laboratories, to ensure the accuracy and comparability of quantitative bacteria examination results, and to improve the quality of monitoring. The 4 different concentration aerobic plate count piece samples were prepared and noted as I, II, III and IV. After homogeneity and stability tests, the samples were delivered to monitoring institutions. The results of I, II, III samples were logarithmic transformed, and evaluated with Z-score method using the robust average and standard deviation. The results of IV samples were evaluated as "satisfactory" when reported as < 10 CFU/piece or as "not satisfactory" otherwise. Pearson χ2 test was used to analyze the ratio results. 309 monitoring institutions, which was 99.04% of the total number, reported their results. 271 institutions reported a satisfactory result, and the satisfactory rate was 87.70%. There was no statistical difference in satisfactory rates of I, II and III samples which were 81.52%, 88.30% and 91.40% respectively. The satisfactory rate of IV samples was 93.33%. There was no statistical difference in satisfactory rates between provincial and municipal CDC. The quality control program has provided scientific data that the aerobic plate count capability of the laboratories meets the requirements of monitoring tasks.

  15. Aircraft model prototypes which have specified handling-quality time histories

    NASA Technical Reports Server (NTRS)

    Johnson, S. H.

    1978-01-01

    Several techniques for obtaining linear constant-coefficient airplane models from specified handling-quality time histories are discussed. The pseudodata method solves the basic problem, yields specified eigenvalues, and accommodates state-variable transfer-function zero suppression. The algebraic equations to be solved are bilinear, at worst. The disadvantages are reduced generality and no assurance that the resulting model will be airplane like in detail. The method is fully illustrated for a fourth-order stability-axis small motion model with three lateral handling quality time histories specified. The FORTRAN program which obtains and verifies the model is included and fully documented.

  16. 75 FR 75455 - Certain Hot-Rolled Flat-Rolled Carbon-Quality Steel Products From Brazil: Final Results of Full...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-03

    ...-Rolled Carbon-Quality Steel Products From Brazil: Final Results of Full Sunset Review of Countervailing... of the countervailing duty (CVD) order on certain hot-rolled flat-rolled carbon-quality steel products (hot-rolled steel) from Brazil, pursuant to section 751(c) of the Tariff Act of 1930, as amended...

  17. The use of ion beam cleaning to obtain high quality cold welds with minimal deformation

    NASA Technical Reports Server (NTRS)

    Sater, B. L.; Moore, T. J.

    1978-01-01

    This paper describes a variation of cold welding which utilizes an ion beam to clean mating surfaces prior to joining in a vacuum environment. High quality solid state welds were produced with minimal deformation. Due to experimental fixture limitation in applying pressure work has been limited to a few low yield strength materials.

  18. Ten-year results of quality assurance in radiotherapy chart round.

    PubMed

    Taghavi Bayat, Bardia; Gill, Suki; Siva, Shankar; Tai, Keen Hun; Joon, Michael Lim; Foroudi, Farshad

    2013-04-23

    The Royal Australian and New Zealand College of Radiologists (RANZCR) initiated a unique instrument to audit the quality of patient notes and radiotherapy prescriptions. We present our experience collected over ten years from the use of the RANZCR audit instrument. In this study, the results of data collected prospectively from January 1999 to June 2009 through the audit instrument were assessed. Radiotherapy chart rounds were held weekly in the uro-oncology tumour stream and real time feedback was provided. Electronic medical records were retrospectively assessed in September 2009 to see if any omissions were subsequently corrected. In total 2597 patients were audited. One hundred and thirty seven (5%) patients had one hundred and ninety nine omissions in documentation or radiotherapy prescription. In 79% of chart rounds no omissions were found at all, in 12% of chart rounds one omission was found and in 9% of chart rounds two or more omissions were found. Out of 199 omissions, 95% were of record keeping and 2% were omissions in the treatment prescription. Of omissions, 152 (76%) were unfiled investigation results of which 77 (51%) were subsequently corrected. Real-time audit with feedback is an effective tool in assessing the standards of radiotherapy documentation in our department, and also probably contributed to the high level of attentiveness. A large proportion of omissions were investigation results, which highlights the need for an improved system of retrieval of investigation results in the radiation oncology department.

  19. External quality assurance of HER2 fluorescence in situ hybridisation testing: results of a UK NEQAS pilot scheme

    PubMed Central

    Bartlett, John M S; Ibrahim, Merdol; Jasani, Bharat; Morgan, John M; Ellis, Ian; Kay, Elaine; Magee, Hilary; Barnett, Sarah; Miller, Keith

    2007-01-01

    Background and Aims Trastuzumab provides clinical benefit for advanced and early breast cancer patients whose tumours over‐express or have gene amplification of the HER2 oncogene. The UK National External Quality Assessment Scheme (NEQAS) for immunohistochemical testing was established to assess and improve the quality of HER2 immunohistochemical testing. However, until recently, no provision was available for HER2 fluorescence in situ hybridisation (FISH) testing. A pilot scheme was set up to review the performance of FISH testing in clinical diagnostic laboratories. Methods FISH was performed in 6 reference and 31 participating laboratories using a cell line panel with known HER2 status. Results Using results from reference laboratories as a criterion for acceptable performance, 60% of all results returned by participants were appropriate and 78% either appropriate or acceptable. However, 22.4% of results returned were deemed inappropriate, including 13 cases (4.2%) where a misdiagnosis would have been made had these been clinical specimens. Conclusions The results of three consecutive runs show that both reference laboratories and a proportion of routine clinical diagnostic (about 25%) centres can consistently achieve acceptable quality control of HER2 testing. Data from a significant proportion of participating laboratories show that further steps are required, including those taken via review of performance under schemes such as NEQAS, to improve quality of HER2 testing by FISH in the “real world”. PMID:16963466

  20. Quality of Diabetes Care: The Challenges of an Increasing Epidemic in Mexico. Results from Two National Health Surveys (2006 and 2012).

    PubMed

    Flores-Hernández, Sergio; Saturno-Hernández, Pedro J; Reyes-Morales, Hortensia; Barrientos-Gutiérrez, Tonatiuh; Villalpando, Salvador; Hernández-Ávila, Mauricio

    2015-01-01

    The quality of diabetes care remains suboptimal according to numerous studies assessing the achievement of quality indicators for diabetes care in various healthcare settings. We report about global and specific quality indicators for diabetes care and their association to glycemic control at the population level in two national health surveys in Mexico. We conducted a cross-sectional analysis of the 2006 and 2012 National Health Surveys in Mexico. We examined quality of care for 2,965 and 4,483 adults (≥ 20 years) with diagnosed type 2 diabetes using fourteen simple and two composite indicators derived from self-reported information. In a subsample for both surveys, glycated hemoglobin (HbA1c) was measured at the time of the interview. We obtained survey weight-adjusted estimators using multiple regression models (logistic and linear) with combined data files, including survey year as covariate to assess change. Global quality of care in 2012 was 40.8%, with a relative improvement of 11.7% between 2006 and 2012. Detections of cardiovascular disease risk factors (dyslipidemia and hypertension) were the indicators with the highest improvement, while non-pharmaceutical treatment and diabetic foot exams showed minor changes. We found a significant association between the quality of the process of diabetes care and glycemic control (OR 2.53, 95% CI 1.63-3.94). Age more than 65 years old, the type of health subsystem, gender (males), and high socio-economic status were also significantly associated to glycemic control. Quality diabetes care and glycemic control improved and are significantly associated. However, according to international standards, the current situation remains suboptimal. A more holistic approach is needed, with an emphasis on improving quality in outpatient care.

  1. Four-dimensional evaluation of regional air quality models

    EPA Science Inventory

    We present highlights of the results obtained in the third phase of the Air Quality Model Evaluation International Initiative (AQMEII3). Activities in AQMEII3 were focused on evaluating the performance of global, hemispheric and regional modeling systems over Europe and North Ame...

  2. Results of in vivo measurements of strontium-90 body-burden in Urals residents: analyses of data obtained 2006-2012

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tolstykh, E. I.; Bougrov, N. G.; Krivoshchapov, Victor A.

    2012-06-01

    A part of the Urals territory was contaminated with 90Sr and 137Cs in the 1950s as a result of accidents at the "Mayak" Production Association. The paper describes the analysis of in vivo 90Sr measurements in Urals residents. The measurements were performed with the use of whole-body-counter SICH-9.1M in 2006-2012. Totally 5840 measurements for 4876 persons were performed from 2006 to 2012; maximal measured value was 24 kBq. Earlier, similar measurements were performed with SICH-9.1 (1974-1997). Comparison of the results obtained with SICH-9.1 and SICH-9.1M has shown a good agreement of the two data sets.

  3. FQC Dashboard: integrates FastQC results into a web-based, interactive, and extensible FASTQ quality control tool

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Joseph; Pirrung, Meg; McCue, Lee Ann

    FQC is software that facilitates quality control of FASTQ files by carrying out a QC protocol using FastQC, parsing results, and aggregating quality metrics into an interactive dashboard designed to richly summarize individual sequencing runs. The dashboard groups samples in dropdowns for navigation among the data sets, utilizes human-readable configuration files to manipulate the pages and tabs, and is extensible with CSV data.

  4. Groundwater-quality data in the northern Coast Ranges study unit, 2009: Results from the California GAMA Program

    USGS Publications Warehouse

    Mathany, Timothy M.; Dawson, Barbara J.; Shelton, Jennifer L.; Belitz, Kenneth

    2011-01-01

    This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, untreated groundwater typically is treated, disinfected, and (or) blended with other waters to maintain water quality. Regulatory benchmarks apply to water that is served to the consumer, not to untreated groundwater. However, to provide some context for the results, concentrations of constituents measured in the untreated groundwa

  5. FQC Dashboard: integrates FastQC results into a web-based, interactive, and extensible FASTQ quality control tool

    DOE PAGES

    Brown, Joseph; Pirrung, Meg; McCue, Lee Ann

    2017-06-09

    FQC is software that facilitates quality control of FASTQ files by carrying out a QC protocol using FastQC, parsing results, and aggregating quality metrics into an interactive dashboard designed to richly summarize individual sequencing runs. The dashboard groups samples in dropdowns for navigation among the data sets, utilizes human-readable configuration files to manipulate the pages and tabs, and is extensible with CSV data.

  6. [Service quality in health care: the application of the results of marketing research].

    PubMed

    Verheggen, F W; Harteloh, P P

    1993-01-01

    This paper deals with quality assurance in health care and its relation to quality assurance in trade and industry. We present the service quality model--a model of quality from marketing research--and discuss how it can be applied to health care. Traditional quality assurance appears to have serious flaws. It lacks a general theory of the sources of hazards in the complex process of patient care and tends to stagnate, for no real improvement takes place. Departing from this criticism, modern quality assurance in health care is marked by: defining quality in a preferential sense as "fitness for use"; the use of theories and models of trade and industry (process-control); an emphasis on analyzing the process, instead of merely inspecting it; use of the Deming problem solving technique (plan, do, check, act); improvement of the process of care by altering perceptions of parties involved. We present an experience of application and utilization of this method in the University Hospital Maastricht, The Netherlands. The successful application of this model requires a favorable corporate culture and motivation of the health care workers. This model provides a useful framework to uplift the traditional approach to quality assurance in health care.

  7. External quality assurance of HER2 fluorescence in situ hybridisation testing: results of a UK NEQAS pilot scheme.

    PubMed

    Bartlett, John M S; Ibrahim, Merdol; Jasani, Bharat; Morgan, John M; Ellis, Ian; Kay, Elaine; Magee, Hilary; Barnett, Sarah; Miller, Keith

    2007-07-01

    Trastuzumab provides clinical benefit for advanced and early breast cancer patients whose tumours over-express or have gene amplification of the HER2 oncogene. The UK National External Quality Assessment Scheme (NEQAS) for immunohistochemical testing was established to assess and improve the quality of HER2 immunohistochemical testing. However, until recently, no provision was available for HER2 fluorescence in situ hybridisation (FISH) testing. A pilot scheme was set up to review the performance of FISH testing in clinical diagnostic laboratories. FISH was performed in 6 reference and 31 participating laboratories using a cell line panel with known HER2 status. Using results from reference laboratories as a criterion for acceptable performance, 60% of all results returned by participants were appropriate and 78% either appropriate or acceptable. However, 22.4% of results returned were deemed inappropriate, including 13 cases (4.2%) where a misdiagnosis would have been made had these been clinical specimens. The results of three consecutive runs show that both reference laboratories and a proportion of routine clinical diagnostic (about 25%) centres can consistently achieve acceptable quality control of HER2 testing. Data from a significant proportion of participating laboratories show that further steps are required, including those taken via review of performance under schemes such as NEQAS, to improve quality of HER2 testing by FISH in the "real world".

  8. Microstructure investigation of 13Cr-2Mo ODS steel components obtained by high voltage electric discharge compaction technique

    DOE PAGES

    Bogachev, Igor; Yudin, Artem; Grigoryev, Evgeniy; ...

    2015-11-02

    Refractory oxide dispersion strengthened 13Cr-2Mo steel powder was successfully consolidated to near theoretical density using high voltage electric discharge compaction. Cylindrical samples with relative density from 90% to 97% and dimensions of 10 mm in diameter and 10–15 mm in height were obtained. Consolidation conditions such as pressure and voltage were varied in some ranges to determine the optimal compaction regime. Three different concentrations of yttria were used to identify its effect on the properties of the samples. It is shown that the utilized ultra-rapid consolidation process in combination with high transmitted energy allows obtaining high density compacts, retaining themore » initial structure with minimal grain growth. The experimental results indicate some heterogeneity of the structure which may occur in the external layers of the tested samples due to various thermal and electromagnetic in-processing effects. As a result, the choice of the optimal parameters of the consolidation enables obtaining samples of acceptable quality.« less

  9. Idaho's surface-water-quality monitoring program: results from five sites sampled during water years 1990-93

    USGS Publications Warehouse

    ,

    1994-01-01

    In 1990, the U.S. Geological Survey (USGS), in cooperation with the Idaho Department of Health and Welfare, Division of Environmental Quality, implemented a statewide water-quality monitoring program in response to Idaho's antidegradation policy as required by the Clean Water Act. The program objective is to provide water-quality managers with a coordinated statewide network to detect trends in surface-water quality. The monitoring program includes the collection and analysis of samples from 56 sites on the Bear, Clearwater, Kootenai, Pend Oreille, Salmon, Snake, and Spokane Rivers and their tributaries (fig. 1). Samples are collected every year at 5 sites (annual sites) in drainage basins where long-term water-quality management is practiced, every other year at 19 sites (biennial sites) in basins where land and water uses change slowly, and every third year at 32 sites (triennial sites) where future development may affect water quality. Each year, 25 of the 56 sites are sampled. This report discusses results of sampling at five annual sites. During water years 1990-93 (October 1, 1989, through September 30, 1993), samples were collected six times per year at the five annual sites (fig. 1). Onsite analyses were made for discharge, specific conductance, pH, temperature, dissolved oxygen, bacteria (fecal coliform and fecal streptococci), and alkalinity. Laboratory analyses were made for major ions, nutrients, trace elements, and suspended sediment. Suspended sediment, nitrate, fecal coliform, trace elements, and specific conductance were used to characterize surface-water quality. Because concentrations of all trace elements except zinc were near detection limits, only zinc is discussed.

  10. Functionality of hospital information systems: results from a survey of quality directors at Turkish hospitals.

    PubMed

    Saluvan, Mehmet; Ozonoff, Al

    2018-01-12

    We aimed to determine availability of core Hospital Information Systems (HIS) functions implemented in Turkish hospitals and the perceived importance of these functions on quality and patient safety. We surveyed quality directors (QDs) at civilian hospitals in the nation of Turkey. Data were collected via web survey using an instrument with 50 items describing core functionality of HIS. We calculated mean availability of each function, mean and median values of perceived impact on quality, and we investigated the relationship between availability and perceived importance. We received responses from 31% of eligible institutions, representing all major geographic regions of Turkey. Mean availability of 50 HIS functions was 65.6%, ranging from 19.6% to 97.4%. Mean importance score was 7.87 (on a 9-point scale) ranging from 7.13 to 8.41. Functions related to result management (89.3%) and decision support systems (52.2%) had the highest and lowest reported availability respectively. Availability and perceived importance were moderately correlated (r = 0.52). QDs report high importance of the HIS functions surveyed as they relate to quality and patient safety. Availability and perceived importance of HIS functions are generally correlated, with some interesting exceptions. These findings may inform future investments and guide policy changes within the Turkish healthcare system. Financial incentives, regulations around certified HIS, revisions to accreditation manuals, and training interventions are all policies which will help integrate HIS functions to support quality and patient safety in Turkish hospitals.

  11. Summary of results of NASA F-15 flight research program

    NASA Technical Reports Server (NTRS)

    Burcham, F. W., Jr.; Trippensee, G. A.; Fisher, D. F.; Putnam, T. W.

    1986-01-01

    NASA conducted a multidisciplinary flight research program on the F-15 airplane. The program began in 1976 when two preproduction airplanes were obtained from the U.S. Air Force. Major projects involved stability and control, handling qualities, propulsion, aerodynamics, propulsion controls, and integrated propulsion-flight controls. Several government agencies and aerospace contractors were involved. In excess of 330 flights were flown, and over 85 papers and reports were published. This document describes the overall program, the projects, and the key results. The F-15 was demonstrated to be an excellent flight research vehicle, producing high-quality results.

  12. [Development of quality assurance/quality control web system in radiotherapy].

    PubMed

    Okamoto, Hiroyuki; Mochizuki, Toshihiko; Yokoyama, Kazutoshi; Wakita, Akihisa; Nakamura, Satoshi; Ueki, Heihachi; Shiozawa, Keiko; Sasaki, Koji; Fuse, Masashi; Abe, Yoshihisa; Itami, Jun

    2013-12-01

    Our purpose is to develop a QA/QC (quality assurance/quality control) web system using a server-side script language such as HTML (HyperText Markup Language) and PHP (Hypertext Preprocessor), which can be useful as a tool to share information about QA/QC in radiotherapy. The system proposed in this study can be easily built in one's own institute, because HTML can be easily handled. There are two desired functions in a QA/QC web system: (i) To review the results of QA/QC for a radiotherapy machine, manuals, and reports necessary for routinely performing radiotherapy through this system. By disclosing the results, transparency can be maintained, (ii) To reveal a protocol for QA/QC in one's own institute using pictures and movies relating to QA/QC for simplicity's sake, which can also be used as an educational tool for junior radiation technologists and medical physicists. By using this system, not only administrators, but also all staff involved in radiotherapy, can obtain information about the conditions and accuracy of treatment machines through the QA/QC web system.

  13. The relationship of the local food environment with obesity: A systematic review of methods, study quality and results

    PubMed Central

    Cobb, Laura K; Appel, Lawrence J; Franco, Manuel; Jones-Smith, Jessica C; Nur, Alana; Anderson, Cheryl AM

    2015-01-01

    Objective To examine the relationship between local food environments and obesity and assess the quality of studies reviewed. Methods Systematic keyword searches identified studies from US and Canada that assessed the relationship of obesity to local food environments. We applied a quality metric based on design, exposure and outcome measurement, and analysis. Results We identified 71 studies representing 65 cohorts. Overall, study quality was low; 60 studies were cross-sectional. Associations between food outlet availability and obesity were predominantly null. Among non-null associations, we saw a trend toward inverse associations between supermarket availability and obesity (22 negative, 4 positive, 67 null) and direct associations between fast food and obesity (29 positive, 6 negative, 71 null) in adults. We saw direct associations between fast food availability and obesity in lower income children (12 positive, 7 null). Indices including multiple food outlets were most consistently associated with obesity in adults (18 expected, 1 not expected, 17 null). Limiting to higher quality studies did not affect results. Conclusions Despite the large number of studies, we found limited evidence for associations between local food environments and obesity. The predominantly null associations should be interpreted cautiously due to the low quality of available studies. PMID:26096983

  14. Groundwater Quality Data in the Mojave Study Unit, 2008: Results from the California GAMA Program

    USGS Publications Warehouse

    Mathany, Timothy M.; Belitz, Kenneth

    2009-01-01

    ground water. In total, over 230 constituents and water-quality indicators (field parameters) were investigated. Three types of quality-control samples (blanks, replicates, and matrix spikes) each were collected at approximately 5-8 percent of the wells, and the results for these samples were used to evaluate the quality of the data for the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a significant source of bias in the data for the groundwater samples. Differences between replicate samples generally were within acceptable ranges, indicating acceptable analytical reproducibility. Matrix spike recoveries were within acceptable ranges for most compounds. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, untreated groundwater typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to untreated ground water. However, to provide some context for the results, concentrations of constituents measured in the untreated ground water were compared with regulatory and non-regulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH) and thresholds established for aesthetic and technical concerns by CDPH. Comparisons between data collected for this study and thresholds for drinking-water are for illustrative purposes only, and are not indicative of compliance or non-compliance with those thresholds. Most constituents that were detected in groundwater samples in the 59 wells in MOJO were found at concentrations below drinking-water thresholds. In MOJO's 52 grid wells, volatile organic compounds (VOCs) were detected in 40 percent of the wells, and pesticides and pesticide degradates were detected in 23 percent of the grid wel

  15. Ground-Water Quality Data in the Central Sierra Study Unit, 2006 - Results from the California GAMA Program

    USGS Publications Warehouse

    Ferrari, Matthew J.; Fram, Miranda S.; Belitz, Kenneth

    2008-01-01

    the results for these samples were used to evaluate the quality of the data for the ground-water samples. Results from field blanks indicated contamination was not a noticeable source of bias in the data for ground-water samples. Differences between replicate samples were within acceptable ranges, indicating acceptably low variability. Matrix spike recoveries were within acceptable ranges for most constituents. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH), and thresholds established for aesthetic concerns (Secondary Maximum Contaminant Levels, SMCL-CA) by CDPH. Therefore, any comparisons of the results of this study to drinking-water standards only is for illustrative purposes and is not indicative of compliance or non-compliance to those standards. Most constituents that were detected in ground-water samples were found at concentrations below drinking-water standards or thresholds. Six constituents? fluoride, arsenic, molybdenum, uranium, gross-alpha radioactivity, and radon-222?were detected at concentrations higher than thresholds set for health-based regulatory purposes. Three additional constituents?pH, iron and manganese?were detected at concentrations above thresholds set for aesthetic concerns. Volatile organic compounds (VOCs) and pesticides, were detected in less than one-third of the samples and generally at less than one one-hundredth of a health-based threshold.

  16. Image Quality Performance Measurement of the microPET Focus 120

    NASA Astrophysics Data System (ADS)

    Ballado, Fernando Trejo; López, Nayelli Ortega; Flores, Rafael Ojeda; Ávila-Rodríguez, Miguel A.

    2010-12-01

    The aim of this work is to evaluate the characteristics involved in the image reconstruction of the microPET Focus 120. For this evaluation were used two different phantoms; a miniature hot-rod Derenzo phantom and a National Electrical Manufacturers Association (NEMA) NU4-2008 image quality (IQ) phantom. The best image quality was obtained when using OSEM3D as the reconstruction method reaching a spatial resolution of 1.5 mm with the Derenzo phantom filled with 18F. Image quality test results indicate a superior image quality for the Focus 120 when compared to previous microPET models.

  17. A simple parametric model observer for quality assurance in computer tomography

    NASA Astrophysics Data System (ADS)

    Anton, M.; Khanin, A.; Kretz, T.; Reginatto, M.; Elster, C.

    2018-04-01

    Model observers are mathematical classifiers that are used for the quality assessment of imaging systems such as computer tomography. The quality of the imaging system is quantified by means of the performance of a selected model observer. For binary classification tasks, the performance of the model observer is defined by the area under its ROC curve (AUC). Typically, the AUC is estimated by applying the model observer to a large set of training and test data. However, the recording of these large data sets is not always practical for routine quality assurance. In this paper we propose as an alternative a parametric model observer that is based on a simple phantom, and we provide a Bayesian estimation of its AUC. It is shown that a limited number of repeatedly recorded images (10–15) is already sufficient to obtain results suitable for the quality assessment of an imaging system. A MATLAB® function is provided for the calculation of the results. The performance of the proposed model observer is compared to that of the established channelized Hotelling observer and the nonprewhitening matched filter for simulated images as well as for images obtained from a low-contrast phantom on an x-ray tomography scanner. The results suggest that the proposed parametric model observer, along with its Bayesian treatment, can provide an efficient, practical alternative for the quality assessment of CT imaging systems.

  18. Fuzzy C-Means Algorithm for Segmentation of Aerial Photography Data Obtained Using Unmanned Aerial Vehicle

    NASA Astrophysics Data System (ADS)

    Akinin, M. V.; Akinina, N. V.; Klochkov, A. Y.; Nikiforov, M. B.; Sokolova, A. V.

    2015-05-01

    The report reviewed the algorithm fuzzy c-means, performs image segmentation, give an estimate of the quality of his work on the criterion of Xie-Beni, contain the results of experimental studies of the algorithm in the context of solving the problem of drawing up detailed two-dimensional maps with the use of unmanned aerial vehicles. According to the results of the experiment concluded that the possibility of applying the algorithm in problems of decoding images obtained as a result of aerial photography. The considered algorithm can significantly break the original image into a plurality of segments (clusters) in a relatively short period of time, which is achieved by modification of the original k-means algorithm to work in a fuzzy task.

  19. Model-based monitoring of stormwater runoff quality.

    PubMed

    Birch, Heidi; Vezzaro, Luca; Mikkelsen, Peter Steen

    2013-01-01

    Monitoring of micropollutants (MP) in stormwater is essential to evaluate the impacts of stormwater on the receiving aquatic environment. The aim of this study was to investigate how different strategies for monitoring of stormwater quality (combining a model with field sampling) affect the information obtained about MP discharged from the monitored system. A dynamic stormwater quality model was calibrated using MP data collected by automatic volume-proportional sampling and passive sampling in a storm drainage system on the outskirts of Copenhagen (Denmark) and a 10-year rain series was used to find annual average (AA) and maximum event mean concentrations. Use of this model reduced the uncertainty of predicted AA concentrations compared to a simple stochastic method based solely on data. The predicted AA concentration, obtained by using passive sampler measurements (1 month installation) for calibration of the model, resulted in the same predicted level but with narrower model prediction bounds than by using volume-proportional samples for calibration. This shows that passive sampling allows for a better exploitation of the resources allocated for stormwater quality monitoring.

  20. Harmonization of urine albumin/creatinine ratio (ACR) results: a study based on an external quality assessment program in Polish laboratories.

    PubMed

    Ćwiklińska, Agnieszka; Dąbrowska, Hanna; Kowalski, Robert; Kuchta, Agnieszka; Kortas-Stempak, Barbara; Fijałkowska, Aleksandra; Bednarczuk, Gabriela; Jankowski, Maciej

    2018-05-11

    The ratio of albumin to creatinine (ACR) is an important parameter used for detection of albuminuria in patients with early kidney damage. The aim of the study was to evaluate the harmonization of ACR results among Polish participants in an international external quality assessment (EQA) program, and to evaluate the impact of albumin and creatinine analytical performance on the harmonization of ACR results. We analyzed 182 results of albumin, 202 of creatinine, and 180 of ACR obtained from Polish laboratories in an EQA program organized by Labquality. The dispersion of the results in surveys and percentage differences between the results and target values were calculated. Moreover, differences between method groups were assessed. The inter-laboratory coefficient of variation (CV) for ACR was 36%. Only 74% of results of Polish laboratories were within the target limits; for 11% of the results, an incorrect albuminuria category would have been reported. The inter-laboratory CV for albumin was 20%, 2.6-fold higher than for creatinine. Significant differences between method groups for albumin determination have been observed, even when the same measurement technique was used. The greatest difference between two groups was 23%, 2.5-fold greater in comparison to creatinine. There is an insufficient harmonization of ACR values among Polish laboratories, caused mainly by urine albumin analytical performance. Given the important role of ACR in the classification, monitoring and treatment of kidney damage, the harmonization of albumin measurements is crucial and urgently needed.

  1. The Satellite based Monitoring Initiative for Regional Air quality (SAMIRA): Project summary and first results

    NASA Astrophysics Data System (ADS)

    Schneider, Philipp; Stebel, Kerstin; Ajtai, Nicolae; Diamandi, Andrei; Horalek, Jan; Nemuc, Anca; Stachlewska, Iwona; Zehner, Claus

    2017-04-01

    We present a summary and some first results of a new ESA-funded project entitled Satellite based Monitoring Initiative for Regional Air quality (SAMIRA), which aims at improving regional and local air quality monitoring through synergetic use of data from present and upcoming satellite instruments, traditionally used in situ air quality monitoring networks and output from chemical transport models. Through collaborative efforts in four countries, namely Romania, Poland, the Czech Republic and Norway, all with existing air quality problems, SAMIRA intends to support the involved institutions and associated users in their national monitoring and reporting mandates as well as to generate novel research in this area. The primary goal of SAMIRA is to demonstrate the usefulness of existing and future satellite products of air quality for improving monitoring and mapping of air pollution at the regional scale. A total of six core activities are being carried out in order to achieve this goal: Firstly, the project is developing and optimizing algorithms for the retrieval of hourly aerosol optical depth (AOD) maps from the Spinning Enhanced Visible and InfraRed Imager (SEVIRI) onboard of Meteosat Second Generation. As a second activity, SAMIRA aims to derive particulate matter (PM2.5) estimates from AOD data by developing robust algorithms for AOD-to-PM conversion with the support from model- and Lidar data. In a third activity, we evaluate the added value of satellite products of atmospheric composition for operational European-scale air quality mapping using geostatistics and auxiliary datasets. The additional benefit of satellite-based monitoring over existing monitoring techniques (in situ, models) is tested by combining these datasets using geostatistical methods and demonstrated for nitrogen dioxide (NO2), sulphur dioxide (SO2), and aerosol optical depth/particulate matter. As a fourth activity, the project is developing novel algorithms for downscaling coarse

  2. Effect of four types of dietary fiber on the technological quality of pasta.

    PubMed

    Bustos, M C; Pérez, G T; León, A E

    2011-06-01

    The development of dietary fiber-enriched foods permits to obtain products with functional properties but can cause several problems in technological quality. The aim of this study was to study the quality of pasta obtained by replacing bread wheat flour with resistant starch II (RSII), resistant starch IV (RSIV), oat bran (OB) and inulin (IN) with the purpose of improving their nutritional quality. RSII, RSIV, OB and IN were substituted for a portion of bread wheat flour at levels 2.5%, 5.0%, 7.5% and 10.0%. Cooking properties, amylose and inulin losses, color and texture were measured. Finally, nutritional quality of enriched pasta was evaluated by protein losses during cooking and total dietary fiber. Microstructure of pasta was analyzed by scanning electron microscopy. Addition of RSII into pasta formulation improved the quality of the final product. RSIV-enriched pasta presented an improvement in textural characteristics and OB affected cooking properties positively up to 5% of substitution. Inulin was lost during cooking; besides, its addition negatively affected the technological quality of pasta. The results obtained in this study prove that it is possible to elaborate pasta with acceptable cooking quality and with improved nutritional characteristics by adding 10% of RSII and RSIV and 5% of OB.

  3. Results of a one-day, descriptive study of quality of life in patients with chronic wounds.

    PubMed

    Shukla, Vijay K; Shukla, Dinesh; Tripathi, Anuj K; Agrawal, Saurabh; Tiwary, Satyendra K; Prakash, Vivek

    2008-05-01

    Quality of life is a subjectively interpreted phenomenon that can be profoundly altered by the presence of a wound. Particularly when complete and expedient healing seems unrealistic, quality of life becomes the focus of care. To assess the influence of a variety of chronic wounds on patient quality of life, a 1-day, descriptive study was conducted among 50 consecutive outpatients (64% men, 36% women; age range 14 to 78 years) with chronic wounds who attended the Wound Clinic of the University Hospital, Varanasi, India. A quality-of-life questionnaire containing six parameters (physical activities, feelings, household duties, leisure time activities, social relations, and general activities) was developed and administered. Demographic information was available as a result of a previous study at this institution. Quality-of-life scores were grouped as satisfactory and unsatisfactory and participants were grouped by age (<30 years old, 30 to 60 years old, >60 years old). Wounds were classified by cause (diabetes, venous disease, pressure ulcer, and tuberculosis) and size (<10 cm2, 10 to 50 cm2, >50 cm2). The most common site was the lower limb or foot (39, 78%), followed by upper limb (six, 12%) and head, neck, and trunk (five, 10%). More than half (28, 56%) of all patients had an unsatisfactory overall quality-of-life score. The percentage of patients with satisfactory scores was higher in patients with smaller versus larger wounds and wounds located on upper rather than lower limbs, as well as in middle-aged versus younger or older patients. This patient-centered instrument helped document important quality-of-life concerns among chronic wound patients.

  4. Quantification of active pharmaceutical ingredient and impurities in sildenafil citrate obtained from the Internet.

    PubMed

    Veronin, Michael A; Nutan, Mohammad T; Dodla, Uday Krishna Reddy

    2014-10-01

    The accessibility of prescription drugs produced outside of the United States, most notably sildenafil citrate (innovator product, Viagra®), has been made much easier by the Internet. Of greatest concern to clinicians and policymakers is product quality and patient safety. The US Food and Drug Administration (FDA) has issued warnings to potential buyers that the safety of drugs purchased from the Internet cannot be guaranteed, and may present a health risk to consumers from substandard products. The objective of this study was to determine whether generic sildenafil citrate tablets from international markets obtained via the Internet are equivalent to the US innovator product regarding major aspects of pharmaceutical quality: potency, accuracy of labeling, and presence and level of impurities. This will help identify aspects of drug quality that may impact public health risks. A total of 15 sildenafil citrate tablets were obtained for pharmaceutical analysis: 14 generic samples from international Internet pharmacy websites and the US innovator product. According to US Pharmacopeial guidelines, tablet samples were tested using high-performance liquid chromatography for potency of active pharmaceutical ingredient (API) and levels of impurities (impurities A, B, C, and D). Impurity levels were compared with International Conference on Harmonisation (ICH) limits. Among the 15 samples, 4 samples possessed higher impurity B levels than the ICH qualification threshold, 8 samples possessed higher impurity C levels than the ICH qualification threshold, and 4 samples possessed more than 1% impurity quantity of maximum daily dose (MDD). For API, 6 of the samples failed to fall within the 5% assay limit. Quality assurance tests are often used to detect formulation defects of drug products during the manufacturing and/or storage process. Results suggest that manufacturing standards for sildenafil citrate generic drug products compared with the US innovator product are not

  5. Relations of Water Quality to Agricultural Chemical Use and Environmental Setting at Various Scales - Results from Selected Studies of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    ,

    2008-01-01

    In 1991, the U.S. Geological Survey (USGS) began studies of 51 major river basins and aquifers across the United States as part of the National Water-Quality Assessment (NAWQA) Program to provide scientifically sound information for managing the Nation's water resources. The major goals of the NAWQA Program are to assess the status and long-term trends of the Nation's surface- and ground-water quality and to understand the natural and human factors that affect it (Gilliom and others, 1995). In 2001, the NAWQA Program began a second decade of intensive water-quality assessments. The 42 study units for this second decade were selected to represent a wide range of important hydrologic environments and potential contaminant sources. These NAWQA studies continue to address the goals of the first decade of the assessments to determine how water-quality conditions are changing over time. In addition to local- and regional-scale studies, NAWQA began to analyze and synthesize water-quality status and trends at the principal aquifer and major river-basin scales. This fact sheet summarizes results from four NAWQA studies that relate water quality to agricultural chemical use and environmental setting at these various scales: * Comparison of ground-water quality in northern and southern High Plains agricultural settings (principal aquifer scale); * Distribution patterns of pesticides and degradates in rain (local scale); * Occurrence of pesticides in shallow ground water underlying four agricultural areas (local and regional scales); and * Trends in nutrients and sediment over time in the Missouri River and its tributaries (major river-basin scale).

  6. Application of reiteration of Hankel singular value decomposition in quality control

    NASA Astrophysics Data System (ADS)

    Staniszewski, Michał; Skorupa, Agnieszka; Boguszewicz, Łukasz; Michalczuk, Agnieszka; Wereszczyński, Kamil; Wicher, Magdalena; Konopka, Marek; Sokół, Maria; Polański, Andrzej

    2017-07-01

    Medical centres are obliged to store past medical records, including the results of quality assurance (QA) tests of the medical equipment, which is especially useful in checking reproducibility of medical devices and procedures. Analysis of multivariate time series is an important part of quality control of NMR data. In this work we proposean anomaly detection tool based on Reiteration of Hankel Singular Value Decomposition method. The presented method was compared with external software and authors obtained comparable results.

  7. Quality Assessment of Urinary Stone Analysis: Results of a Multicenter Study of Laboratories in Europe

    PubMed Central

    Siener, Roswitha; Buchholz, Noor; Daudon, Michel; Hess, Bernhard; Knoll, Thomas; Osther, Palle J.; Reis-Santos, José; Sarica, Kemal; Traxer, Olivier; Trinchieri, Alberto

    2016-01-01

    After stone removal, accurate analysis of urinary stone composition is the most crucial laboratory diagnostic procedure for the treatment and recurrence prevention in the stone-forming patient. The most common techniques for routine analysis of stones are infrared spectroscopy, X-ray diffraction and chemical analysis. The aim of the present study was to assess the quality of urinary stone analysis of laboratories in Europe. Nine laboratories from eight European countries participated in six quality control surveys for urinary calculi analyses of the Reference Institute for Bioanalytics, Bonn, Germany, between 2010 and 2014. Each participant received the same blinded test samples for stone analysis. A total of 24 samples, comprising pure substances and mixtures of two or three components, were analysed. The evaluation of the quality of the laboratory in the present study was based on the attainment of 75% of the maximum total points, i.e. 99 points. The methods of stone analysis used were infrared spectroscopy (n = 7), chemical analysis (n = 1) and X-ray diffraction (n = 1). In the present study only 56% of the laboratories, four using infrared spectroscopy and one using X-ray diffraction, fulfilled the quality requirements. According to the current standard, chemical analysis is considered to be insufficient for stone analysis, whereas infrared spectroscopy or X-ray diffraction is mandatory. However, the poor results of infrared spectroscopy highlight the importance of equipment, reference spectra and qualification of the staff for an accurate analysis of stone composition. Regular quality control is essential in carrying out routine stone analysis. PMID:27248840

  8. Quality Assessment of Urinary Stone Analysis: Results of a Multicenter Study of Laboratories in Europe.

    PubMed

    Siener, Roswitha; Buchholz, Noor; Daudon, Michel; Hess, Bernhard; Knoll, Thomas; Osther, Palle J; Reis-Santos, José; Sarica, Kemal; Traxer, Olivier; Trinchieri, Alberto

    2016-01-01

    After stone removal, accurate analysis of urinary stone composition is the most crucial laboratory diagnostic procedure for the treatment and recurrence prevention in the stone-forming patient. The most common techniques for routine analysis of stones are infrared spectroscopy, X-ray diffraction and chemical analysis. The aim of the present study was to assess the quality of urinary stone analysis of laboratories in Europe. Nine laboratories from eight European countries participated in six quality control surveys for urinary calculi analyses of the Reference Institute for Bioanalytics, Bonn, Germany, between 2010 and 2014. Each participant received the same blinded test samples for stone analysis. A total of 24 samples, comprising pure substances and mixtures of two or three components, were analysed. The evaluation of the quality of the laboratory in the present study was based on the attainment of 75% of the maximum total points, i.e. 99 points. The methods of stone analysis used were infrared spectroscopy (n = 7), chemical analysis (n = 1) and X-ray diffraction (n = 1). In the present study only 56% of the laboratories, four using infrared spectroscopy and one using X-ray diffraction, fulfilled the quality requirements. According to the current standard, chemical analysis is considered to be insufficient for stone analysis, whereas infrared spectroscopy or X-ray diffraction is mandatory. However, the poor results of infrared spectroscopy highlight the importance of equipment, reference spectra and qualification of the staff for an accurate analysis of stone composition. Regular quality control is essential in carrying out routine stone analysis.

  9. Water-quality trends in the nation’s rivers and streams, 1972–2012—Data preparation, statistical methods, and trend results

    USGS Publications Warehouse

    Oelsner, Gretchen P.; Sprague, Lori A.; Murphy, Jennifer C.; Zuellig, Robert E.; Johnson, Henry M.; Ryberg, Karen R.; Falcone, James A.; Stets, Edward G.; Vecchia, Aldo V.; Riskin, Melissa L.; De Cicco, Laura A.; Mills, Taylor J.; Farmer, William H.

    2017-04-04

    Since passage of the Clean Water Act in 1972, Federal, State, and local governments have invested billions of dollars to reduce pollution entering rivers and streams. To understand the return on these investments and to effectively manage and protect the Nation’s water resources in the future, we need to know how and why water quality has been changing over time. As part of the National Water-Quality Assessment Project, of the U.S. Geological Survey’s National Water-Quality Program, data from the U.S. Geological Survey, along with multiple other Federal, State, Tribal, regional, and local agencies, have been used to support the most comprehensive assessment conducted to date of surface-water-quality trends in the United States. This report documents the methods used to determine trends in water quality and ecology because these methods are vital to ensuring the quality of the results. Specific objectives are to document (1) the data compilation and processing steps used to identify river and stream sites throughout the Nation suitable for water-quality, pesticide, and ecology trend analysis, (2) the statistical methods used to determine trends in target parameters, (3) considerations for water-quality, pesticide, and ecology data and streamflow data when modeling trends, (4) sensitivity analyses for selecting data and interpreting trend results with the Weighted Regressions on Time, Discharge, and Season method, and (5) the final trend results at each site. The scope of this study includes trends in water-quality concentrations and loads (nutrient, sediment, major ion, salinity, and carbon), pesticide concentrations and loads, and metrics for aquatic ecology (fish, invertebrates, and algae) for four time periods: (1) 1972–2012, (2) 1982–2012, (3) 1992–2012, and (4) 2002–12. In total, nearly 12,000 trends in concentration, load, and ecology metrics were evaluated in this study; there were 11,893 combinations of sites, parameters, and trend periods. The

  10. Dosimetry and image quality assessment in a direct radiography system

    PubMed Central

    Oliveira, Bruno Beraldo; de Oliveira, Marcio Alves; Paixão, Lucas; Teixeira, Maria Helena Araújo; Nogueira, Maria do Socorro

    2014-01-01

    Objective To evaluate the mean glandular dose with a solid state detector and the image quality in a direct radiography system, utilizing phantoms. Materials and Methods Irradiations were performed with automatic exposure control and polymethyl methacrylate slabs with different thicknesses to calculate glandular dose values. The image quality was evaluated by means of the structures visualized on the images of the phantoms. Results Considering the uncertainty of the measurements, the mean glandular dose results are in agreement with the values provided by the equipment and with internationally adopted reference levels. Results obtained from images of the phantoms were in agreement with the reference values. Conclusion The present study contributes to verify the equipment conformity as regards dose values and image quality. PMID:25741119

  11. Is the maturity of hospitals' quality improvement systems associated with measures of quality and patient safety?

    PubMed Central

    2011-01-01

    Background Previous research addressed the development of a classification scheme for quality improvement systems in European hospitals. In this study we explore associations between the 'maturity' of the hospitals' quality improvement system and clinical outcomes. Methods The maturity classification scheme was developed based on survey results from 389 hospitals in eight European countries. We matched the hospitals from the Spanish sample (113 hospitals) with those hospitals participating in a nation-wide, voluntary hospital performance initiative. We then compared sample distributions and explored associations between the 'maturity' of the hospitals' quality improvement system and a range of composite outcomes measures, such as adjusted hospital-wide mortality, -readmission, -complication and -length of stay indices. Statistical analysis includes bivariate correlations for parametrically and non-parametrically distributed data, multiple robust regression models and bootstrapping techniques to obtain confidence-intervals for the correlation and regression estimates. Results Overall, 43 hospitals were included. Compared to the original sample of 113, this sample was characterized by a higher representation of university hospitals. Maturity of the quality improvement system was similar, although the matched sample showed less variability. Analysis of associations between the quality improvement system and hospital-wide outcomes suggests significant correlations for the indicator adjusted hospital complications, borderline significance for adjusted hospital readmissions and non-significance for the adjusted hospital mortality and length of stay indicators. These results are confirmed by the bootstrap estimates of the robust regression model after adjusting for hospital characteristics. Conclusions We assessed associations between hospitals' quality improvement systems and clinical outcomes. From this data it seems that having a more developed quality improvement

  12. The Impact of the Condenser on Cytogenetic Image Quality in Digital Microscope System

    PubMed Central

    Ren, Liqiang; Li, Zheng; Li, Yuhua; Zheng, Bin; Li, Shibo; Chen, Xiaodong; Liu, Hong

    2013-01-01

    Background: Optimizing operational parameters of the digital microscope system is an important technique to acquire high quality cytogenetic images and facilitate the process of karyotyping so that the efficiency and accuracy of diagnosis can be improved. OBJECTIVE: This study investigated the impact of the condenser on cytogenetic image quality and system working performance using a prototype digital microscope image scanning system. Methods: Both theoretical analysis and experimental validations through objectively evaluating a resolution test chart and subjectively observing large numbers of specimen were conducted. Results: The results show that the optimal image quality and large depth of field (DOF) are simultaneously obtained when the numerical aperture of condenser is set as 60%–70% of the corresponding objective. Under this condition, more analyzable chromosomes and diagnostic information are obtained. As a result, the system shows higher working stability and less restriction for the implementation of algorithms such as autofocusing especially when the system is designed to achieve high throughput continuous image scanning. Conclusions: Although the above quantitative results were obtained using a specific prototype system under the experimental conditions reported in this paper, the presented evaluation methodologies can provide valuable guidelines for optimizing operational parameters in cytogenetic imaging using the high throughput continuous scanning microscopes in clinical practice. PMID:23676284

  13. Hidden consequences of success in pediatrics: parental health-related quality of life--results from the Care Project.

    PubMed

    Hatzmann, Janneke; Heymans, Hugo S A; Ferrer-i-Carbonell, Ada; van Praag, Bernard M S; Grootenhuis, Martha A

    2008-11-01

    The number of parents who care for a chronically ill child is increasing. Because of advances in medical care, parental caring tasks are changing. A detailed description of parental health-related quality of life will add to the understanding of the impact of caring for a chronically ill child. This will contribute to pediatric family care. Our goal was to determine the health-related quality of life of parents of chronically ill children compared with parents of healthy schoolchildren. A survey of 533 parents of children with chronic conditions (10 diagnosis groups, children aged 1-19 years, diagnosed >1 year ago, living at home) and 443 parents of schoolchildren was conducted between January 2006 and September 2007. Parents were approached through Emma Children's Hospital (which has a tertiary referral and a regional function) and through parent associations. The comparison group included parents of healthy schoolchildren. Health-related quality of life was assessed with the TNO-AZL Questionnaire for Adult's Health Related Quality of Life. Health-related quality of life measures gross and fine motor function, cognitive functioning, sleep, pain, social functioning, daily activities, sexuality, vitality, positive and depressive emotions, and aggressiveness. The health-related quality of life of the study group was compared with that of the comparison group, and effect sizes were estimated. The percentages of parents at risk for a low health-related quality of life were compared with the 25th percentile scores of the comparison group. RESULTS. Parents of chronically ill children had a significantly lower health-related quality of life. Subgroup analysis showed lower health-related quality of life on sleep, social functioning, daily activities, vitality, positive emotions, and depressive emotions in disease-specific groups. On average, 45% of the parents were at risk for health-related quality-of-life impairment. Parents of chronically ill children report a seriously

  14. On the use of certified reference materials for assuring the quality of results for the determination of mercury in environmental samples.

    PubMed

    Bulska, Ewa; Krata, Agnieszka; Kałabun, Mateusz; Wojciechowski, Marcin

    2017-03-01

    This work focused on the development and validation of methodologies for the accurate determination of mercury in environmental samples and its further application for the preparation and certification of new reference materials (RMs). Two certified RMs ERM-CC580 (inorganic matrix) and ERM-CE464 (organic matrix) were used for the evaluation of digestion conditions assuring the quantitative recovery of mercury. These conditions were then used for the digestion of new candidates for the environmental RMs: bottom sediment (M_2 BotSed), herring tissue (M_3 HerTis), cormorant tissue (M_4 CormTis), and codfish muscle (M_5 CodTis). Cold vapor atomic absorption spectrometry (CV AAS) and inductively coupled plasma mass spectrometry (ICP MS) were used for the measurement of mercury concentration in all RMs. In order to validate and assure the accuracy of results, isotope dilution mass spectrometry (IDMS) was applied as a primary method of measurement, assuring the traceability of obtained values to the SI units: the mole, the kilogram, and the second. Results obtained by IDMS using n( 200 Hg)/n( 202 Hg) ratio, with estimated combined uncertainty, were as follows: (916 ± 41)/[4.5 %] ng g -1 (M_2 BotSed), (236 ± 14)/[5.9 %] ng g -1 (M_3 HerTis), (2252 ± 54)/[2.4 %] ng g -1 (M_4 CormTis), and (303 ± 15)/[4.9 %] ng g -1 (M_CodTis), respectively. Different types of detection techniques and quantification (external calibration, standard addition, isotope dilution) were applied in order to improve the quality of the analytical results. The good agreement (within less than 2.5 %) between obtained results and those derived from the Inter-laboratory Comparison, executed by the Institute of Nuclear Chemistry and Technology (Warsaw, Poland) on the same sample matrices, further validated the analytical procedures developed in this study, as well as the concentration of mercury in all four new RMs. Although the developed protocol enabling the metrological

  15. Different roles and different results: how activity orientations correspond to relationship quality and student outcomes in school-based mentoring.

    PubMed

    Keller, Thomas E; Pryce, Julia M

    2012-02-01

    This prospective, mixed-methods study investigated how the nature of joint activities between volunteer mentors and student mentees corresponded to relationship quality and youth outcomes. Focusing on relationships in school-based mentoring programs in low-income urban elementary schools, data were obtained through pre-post assessments, naturalistic observations, and in-depth interviews with mentors and mentees. Adopting an exploratory approach, the study employed qualitative case study methods to inductively identify distinctive patterns reflecting the focus of mentoring activities. The activity orientations of relationships were categorized according to the primary functional role embodied by the mentor and the general theme of interactions: teaching assistant/tutoring, friend/engaging, sage/counseling, acquaintance/floundering. Next, these categories were corroborated by comparing the groups on quantitative assessments of relationship quality and change in child outcomes over time. Relationships characterized by sage mentoring, which balanced amicable engagement with adult guidance, were rated most favorably by mentees on multiple measures of relationship quality. Furthermore, students involved in sage mentoring relationships showed declines in depressive symptoms and aggressive behaviors. For disconnected pairs (acquaintances), students reported more negative relationship experiences. Findings suggest effective mentoring relationships represent a hybrid between the friendly mutuality of horizontal relationships and the differential influence of vertical relationships.

  16. Transformation in the pharmaceutical industry: transformation-induced quality risks--a survey.

    PubMed

    Shafiei, Nader; Ford, James L; Morecroft, Charles W; Lisboa, Paulo J; Taylor, Mark J; Mouzughi, Yusra

    2013-01-01

    This paper is the fourth in a series that explores ongoing transformation in the pharmaceutical industry and its impact on pharmaceutical quality from the perspective of risk identification. The aim of this paper is to validate proposed quality risks through elicitation of expert opinion and define the resultant quality risk model. Expert opinion was obtained using a questionnaire-based survey with participants with recognized expertise in pharmaceutical regulation, product lifecycle, or technology. The results of the survey validate the theoretical and operational evidence in support of the four main pharmaceutical transformation triggers previously identified. The quality risk model resulting from the survey indicated a firm relationship between the pharmaceutical quality risks and regulatory compliance outcomes during the marketing approval and post-marketing phases of the product lifecycle and a weaker relationship during the pre-market evaluation phase. In this paper through conduct of an expert opinion survey the proposed quality risks carried forward from an earlier part of the research are validated and resultant quality risk model is defined. The survey results validate the theoretical and operational evidence previously identified. The quality risk model indicates that transformation-related risks have a larger regulatory compliance impact during product approval, manufacturing, distribution, and commercial use than during the development phase.

  17. HOS network-based classification of power quality events via regression algorithms

    NASA Astrophysics Data System (ADS)

    Palomares Salas, José Carlos; González de la Rosa, Juan José; Sierra Fernández, José María; Pérez, Agustín Agüera

    2015-12-01

    This work compares seven regression algorithms implemented in artificial neural networks (ANNs) supported by 14 power-quality features, which are based in higher-order statistics. Combining time and frequency domain estimators to deal with non-stationary measurement sequences, the final goal of the system is the implementation in the future smart grid to guarantee compatibility between all equipment connected. The principal results are based in spectral kurtosis measurements, which easily adapt to the impulsive nature of the power quality events. These results verify that the proposed technique is capable of offering interesting results for power quality (PQ) disturbance classification. The best results are obtained using radial basis networks, generalized regression, and multilayer perceptron, mainly due to the non-linear nature of data.

  18. Ground-Water Quality Data in the Coachella Valley Study Unit, 2007: Results from the California GAMA Program

    USGS Publications Warehouse

    Goldrath, Dara A.; Wright, Michael T.; Belitz, Kenneth

    2009-01-01

    ground water. A quality-control sample (blank, replicate, or matrix spike) was collected at approximately one quarter of the wells, and the results for these samples were used to evaluate the quality of the data for the ground-water samples. Assessment of the quality-control information resulted in V-coding less than 0.1 percent of the data collected. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, and (or) blended with other waters to maintain acceptable water quality. Regulatory thresholds apply to treated water that is supplied to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and the California Department of Public Health (CDPH) and thresholds established for aesthetic purposes (secondary maximum contaminant levels, SMCL-CA) by CDPH. Most constituents detected in ground-water samples were at concentrations below drinking-water thresholds. Volatile organic compounds, pesticides, and pesticide degradates were detected in less than one-third of the grid well samples collected. All VOC and pesticide concentrations measured were below health-based thresholds. Potential waste-water indicators were detected in less than half of the wells sampled, and no detections were above health-based thresholds. Perchlorate was detected in seven grid wells; concentrations from two wells were above the CDPH maximum contaminant level (MCL-CA). Most detections of trace elements in samples collected from COA Study Unit wells were below water-quality thresholds. Exceptions include five samples of arsenic that were above the USEPA maximum contaminant level (MCL-US), two detections of boron above the CDPH notification level (NL-CA), and two detections of mol

  19. Changing physician incentives for affordable, quality cancer care: results of an episode payment model.

    PubMed

    Newcomer, Lee N; Gould, Bruce; Page, Ray D; Donelan, Sheila A; Perkins, Monica

    2014-09-01

    This study tested the combination of an episode payment coupled with actionable use and quality data as an incentive to improve quality and reduce costs. Medical oncologists were paid a single fee, in lieu of any drug margin, to treat their patients. Chemotherapy medications were reimbursed at the average sales price, a proxy for actual cost. Five volunteer medical groups were compared with a large national payer registry of fee-for-service patients with cancer to examine the difference in cost before and after the initiation of the payment change. Between October 2009 and December 2012, the five groups treated 810 patients with breast, colon, and lung cancer using the episode payments. The registry-predicted fee-for-service cost of the episodes cohort was $98,121,388, but the actual cost was $64,760,116. The predicted cost of chemotherapy drugs was $7,519,504, but the actual cost was $20,979,417. There was no difference between the groups on multiple quality measures. Modifying the current fee-for-service payment system for cancer therapy with feedback data and financial incentives that reward outcomes and cost efficiency resulted in a significant total cost reduction. Eliminating existing financial chemotherapy drug incentives paradoxically increased the use of chemotherapy. Copyright © 2014 by American Society of Clinical Oncology.

  20. [Audit system on quality of breast cancer diagnosis and treatment: results of quality indicators on screen-detected lesions in Italy, 2010].

    PubMed

    Ponti, Antonio; Mano, Maria Piera; Tomatis, Mariano; Baiocchi, Diego; Barca, Alessandra; Berti, Rosa; Bisanti, Luigi; Casella, Denise; Deandrea, Silvia; Delrio, Daria; Donati, Giovanni; Falcini, Fabio; Frammartino, Brunella; Frigerio, Alfonso; Mantellini, Paola; Naldoni, Carlo; Orzalesi, Lorenzo; Pagano, Giovanni; Pietribiasi, Francesca; Ravaioli, Alessandra; Sedda, Maria Laura; Taffurelli, Mario; Cataliotti, Luigi; Segnan, Nereo

    2012-01-01

    This survey, conducted by the Italian breast screening network (GISMa), collects yearly individual data on diagnosis and treatment on about 50% of all screen-detected, operated lesions in Italy. The 2010 results show good overall quality and an improving trend over time. Critical issues were identified, including waiting times and compliance with the recommendations on not performing frozen section examination on small lesions. Preoperative diagnosis improved constantly over the years, but there is still a large variation between regions and programmes. For almost 90% of screen-detected invasive cancers the sentinel lymph node technique (SLN) was performed on the axilla, avoiding a large number of potentially harmful dissections. On the other hand, potential overuse of SLN for ductal carcinoma in situ deserves further investigation. The detailed results have been distributed, also by means of a web data warehouse, to regional and local screening programmes in order to allow multidisciplinary discussion and identification of the appropriate solutions to any issues documented by the data. It should be assigned priority to the problem of waiting times. Specialist Breast Units with adequate case volume and enough resources would provide the best setting for making monitoring effective in producing quality improvements with shorter waiting times.

  1. 75 FR 10207 - Certain Cut-to-Length Carbon-Quality Steel Plate From the Republic of Korea: Final Results of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-05

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-580-836] Certain Cut-to-Length Carbon... cut-to-length carbon-quality steel plate from the Republic of Korea and the intent to rescind the... results of the administrative review of the antidumping duty order on certain cut-to-length carbon-quality...

  2. [Patient-doctor interaction in rehabilitation: is there a relationship between perceived interaction quality and long term treatment results?].

    PubMed

    Dibbelt, S; Schaidhammer, M; Fleischer, C; Greitemann, B

    2010-10-01

    showed low but significant correlations with patient-related aspects like coping with disease, health-related knowledge and former positive experiences with physicians. A stepwise regression analysis revealed that interaction quality seems to contribute to enhanced treatment results independently of patients' competences. Our results suggest a positive relationship between perceived interaction quality as defined by the P.A.INT-Questionnaire and treatment effects 6 months after discharge. Comparisons of patient and physician evaluations showed that physicians seem to be successful in building relationships on the affective level but less successful on the instrumental level (i. e., information, structuring and reinforcement). Our data underline the importance of interaction quality for the success of rehabilitation and thus the importance of specific skills such as providing and collecting information, recognizing patients' concerns and goals as well as reinforcement of health-related action. This is especially important when knowledge of disease and coping with disease on patients' side is poor. Interaction quality seems to contribute to better treatment results independently of patients' competences. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Results From the Audit of DOD’s American Recovery and Reinvestment Act of 2009 Initial Data Quality Review Implementation

    DTIC Science & Technology

    2009-11-03

    Results From the Audit of DoD’s American Recovery and Reinvestment Act of 2009 Initial Data Quality Review Implementation Memorandum No. D-2010-RAM...number. 1. REPORT DATE 03 NOV 2009 2. REPORT TYPE 3. DATES COVERED 00-00-2009 to 00-00-2009 4. TITLE AND SUBTITLE Results From the Audit of...SUBJECT: Results From the Audit of DOD’ s American Recovery and Reinvestment Act of2009 Initial Data Quality Review Implementation (Report No. D

  4. Ground-Water Quality Data in the San Francisco Bay Study Unit, 2007: Results from the California GAMA Program

    USGS Publications Warehouse

    Ray, Mary C.; Kulongoski, Justin T.; Belitz, Kenneth

    2009-01-01

    , replicate samples, matrix spike samples) were collected for approximately one-third of the wells, and the results for these samples were used to evaluate the quality of the data for the ground-water samples. Assessment of the quality-control information from the field blanks resulted in applying 'V' codes to approximately 0.1 percent of the data collected for ground-water samples (meaning a constituent was detected in blanks as well as the corresponding environmental data). See the Appendix section 'Quality-Control-Sample Results'. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, and (or) blended with other waters to maintain acceptable water quality. Regulatory thresholds apply to treated water that is delivered to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with regulatory and non-regulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH) and thresholds established for aesthetic concerns (secondary maximum contaminant levels, SMCL-CA) by CDPH. VOCs were detected in about one-half of the grid wells, while pesticides were detected in about one-fifth of the grid wells. Concentrations of all VOCs and pesticides detected in samples from all SFBAY wells were below health-based thresholds. No pharmaceutical compounds were detected in any SFBAY well. One potential wastewater-indicator compound, caffeine, was detected in one grid well in SFBAY. Concentrations of most trace elements and nutrients detected in samples from all SFBAY wells were below health-based thresholds. Exceptions include nitrate, detected above the USEPA maximum contaminant level (MCL-US) in 3samples; arsenic, above the USEPA maximum contaminant level (MCL-US) in 3 samples; c

  5. Ambient Assisted Living and ageing: preliminary results of RITA project.

    PubMed

    Aquilano, Michela; Cavallo, Filippo; Bonaccorsi, Manuele; Esposito, Raffaele; Rovini, Erika; Filippi, Massimo; Esposito, Dario; Dario, Paolo; Carrozza, Maria Chiara

    2012-01-01

    The ageing of population is a social phenomenon that most of worldwide countries are facing. They are, and will be even more in the future, indeed trying to find solutions for improving quality of life of their elderly citizens. The project RITA wants to demonstrate that an update of the current socio-medical services with an Ambient Assisted Living (AAL) approach could improve the service efficiency and the quality of life of both elderly and caregiver. This paper presents the preliminary results obtained in RITA.

  6. Green qualities in the neighbourhood and mental health – results from a longitudinal cohort study in Southern Sweden

    PubMed Central

    2012-01-01

    Background Poor mental health is a major issue worldwide and causality is complex. For diseases with multifactorial background synergistic effects of person- and place- factors can potentially be preventive. Nature is suggested as one such positive place-factor. In this cohort study we tested the effect of defined green qualities (Serene, Space, Wild, Culture, Lush) in the environment at baseline on mental health at follow-up. We also studied interaction effects on mental health of those place factors and varied person factors (financial stress, living conditions, and physical activity). Methods Data on person factors were extracted from a longitudinal (years 1999/2000 and 2005) population health survey (n = 24945). The participants were geocoded and linked to data on green qualities from landscape assessments, and stored in the Geographical Information System (GIS). Crude odds ratios (OR) and 95% confidence intervals (CI) were calculated, and multivariate logistic analyses were performed. Results Mental health was not affected by access to the chosen green qualities, neither in terms of amount nor in terms of any specific quality. However, we found a reduced risk for poor mental health at follow-up among women, through a significant interaction effect between physical activity and access to the qualities Serene or Space. For men the tendencies were similar, though not significant. Regarding the other three green qualities, as well as amount of qualities, no statistically certain synergistic effects were found. Likewise, no significant synergies were detected between green qualities and the other person-factors. Only advanced exercise significantly reduced the risk for poor mental health among women, but not for men, compared to physical inactivity. Conclusions The results do not directly support the hypothesis of a preventive mental health effect by access to the green qualities. However, the additive effect of serene nature to physical activity contributed to

  7. Study of the Relevance of the Quality of Care, Operating Efficiency and Inefficient Quality Competition of Senior Care Facilities.

    PubMed

    Lin, Jwu-Rong; Chen, Ching-Yu; Peng, Tso-Kwei

    2017-09-11

    The purpose of this research is to examine the relation between operating efficiency and the quality of care of senior care facilities. We designed a data envelopment analysis, combining epsilon-based measure and metafrontier efficiency analyses to estimate the operating efficiency for senior care facilities, followed by an iterative seemingly unrelated regression to evaluate the relation between the quality of care and operating efficiency. In the empirical studies, Taiwan census data was utilized and findings include the following: Despite the greater operating scale of the general type of senior care facilities, their average metafrontier technical efficiency is inferior to that of nursing homes. We adopted senior care facility accreditation results from Taiwan as a variable to represent the quality of care and examined the relation of accreditation results and operating efficiency. We found that the quality of care of general senior care facilities is negatively related to operating efficiency; however, for nursing homes, the relationship is not significant. Our findings show that facilities invest more in input resources to obtain better ratings in the accreditation report. Operating efficiency, however, does not improve. Quality competition in the industry in Taiwan is inefficient, especially for general senior care facilities.

  8. Study of the Relevance of the Quality of Care, Operating Efficiency and Inefficient Quality Competition of Senior Care Facilities

    PubMed Central

    Lin, Jwu-Rong; Chen, Ching-Yu; Peng, Tso-Kwei

    2017-01-01

    The purpose of this research is to examine the relation between operating efficiency and the quality of care of senior care facilities. We designed a data envelopment analysis, combining epsilon-based measure and metafrontier efficiency analyses to estimate the operating efficiency for senior care facilities, followed by an iterative seemingly unrelated regression to evaluate the relation between the quality of care and operating efficiency. In the empirical studies, Taiwan census data was utilized and findings include the following: Despite the greater operating scale of the general type of senior care facilities, their average metafrontier technical efficiency is inferior to that of nursing homes. We adopted senior care facility accreditation results from Taiwan as a variable to represent the quality of care and examined the relation of accreditation results and operating efficiency. We found that the quality of care of general senior care facilities is negatively related to operating efficiency; however, for nursing homes, the relationship is not significant. Our findings show that facilities invest more in input resources to obtain better ratings in the accreditation report. Operating efficiency, however, does not improve. Quality competition in the industry in Taiwan is inefficient, especially for general senior care facilities. PMID:28892019

  9. Process perspective on image quality evaluation

    NASA Astrophysics Data System (ADS)

    Leisti, Tuomas; Halonen, Raisa; Kokkonen, Anna; Weckman, Hanna; Mettänen, Marja; Lensu, Lasse; Ritala, Risto; Oittinen, Pirkko; Nyman, Göte

    2008-01-01

    The psychological complexity of multivariate image quality evaluation makes it difficult to develop general image quality metrics. Quality evaluation includes several mental processes and ignoring these processes and the use of a few test images can lead to biased results. By using a qualitative/quantitative (Interpretation Based Quality, IBQ) methodology, we examined the process of pair-wise comparison in a setting, where the quality of the images printed by laser printer on different paper grades was evaluated. Test image consisted of a picture of a table covered with several objects. Three other images were also used, photographs of a woman, cityscape and countryside. In addition to the pair-wise comparisons, observers (N=10) were interviewed about the subjective quality attributes they used in making their quality decisions. An examination of the individual pair-wise comparisons revealed serious inconsistencies in observers' evaluations on the test image content, but not on other contexts. The qualitative analysis showed that this inconsistency was due to the observers' focus of attention. The lack of easily recognizable context in the test image may have contributed to this inconsistency. To obtain reliable knowledge of the effect of image context or attention on subjective image quality, a qualitative methodology is needed.

  10. 42 CFR 478.24 - Opportunity for a party to obtain and submit information.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 4 2011-10-01 2011-10-01 false Opportunity for a party to obtain and submit information. 478.24 Section 478.24 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) QUALITY IMPROVEMENT ORGANIZATIONS RECONSIDERATIONS AND APPEALS...

  11. 42 CFR 478.24 - Opportunity for a party to obtain and submit information.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 4 2014-10-01 2014-10-01 false Opportunity for a party to obtain and submit information. 478.24 Section 478.24 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) QUALITY IMPROVEMENT ORGANIZATIONS RECONSIDERATIONS AND APPEALS...

  12. 42 CFR 478.24 - Opportunity for a party to obtain and submit information.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 4 2013-10-01 2013-10-01 false Opportunity for a party to obtain and submit information. 478.24 Section 478.24 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) QUALITY IMPROVEMENT ORGANIZATIONS RECONSIDERATIONS AND APPEALS...

  13. 42 CFR 478.24 - Opportunity for a party to obtain and submit information.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 4 2012-10-01 2012-10-01 false Opportunity for a party to obtain and submit information. 478.24 Section 478.24 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) QUALITY IMPROVEMENT ORGANIZATIONS RECONSIDERATIONS AND APPEALS...

  14. Results from 15years of quality surveillance for a National Indigenous Point-of-Care Testing Program for diabetes.

    PubMed

    Shephard, Mark; Shephard, Anne; McAteer, Bridgit; Regnier, Tamika; Barancek, Kristina

    2017-12-01

    Diabetes is a major health problem for Australia's Aboriginal and Torres Strait Islander peoples. Point-of-care testing for haemoglobin A1c (HbA1c) has been the cornerstone of a long-standing program (QAAMS) to manage glycaemic control in Indigenous people with diabetes and recently, to diagnose diabetes. The QAAMS quality management framework includes monthly testing of quality control (QC) and external quality assurance (EQA) samples. Key performance indicators of quality include imprecision (coefficient of variation [CV%]) and percentage acceptable results. This paper reports on the past 15years of quality testing in QAAMS and examines the performance of HbA1c POC testing at the 6.5% cut-off recommended for diagnosis. The total number of HbA1c EQA results submitted from 2002 to 2016 was 29,093. The median imprecision for EQA testing by QAAMS device operators averaged 2.81% (SD 0.50; range 2.2 to 3.9%) from 2002 to 2016 and 2.44% (SD 0.22; range 2.2 to 2.9%) from 2009 to 2016. No significant difference was observed between the median imprecision achieved in QAAMS and by Australasian laboratories from 2002 to 2016 (p=0.05; two-tailed paired t-test) and from 2009 to 2016 (p=0.17; two-tailed paired t-test). For QC testing from 2009 to 2016, imprecision averaged 2.5% and 3.0% for the two levels of QC tested. Percentage acceptable results averaged 90% for QA testing from 2002 to 2016 and 96% for QC testing from 2009 to 2016. The DCA Vantage was able to measure a patient and an EQA sample with an HbA1c value close to 6.5% both accurately and precisely. HbA1c POC testing in QAAMS has remained analytically sound, matched the quality achieved by Australasian laboratories and met profession-derived analytical goals for 15years. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  15. Impact of Sleep Quality on Cardiovascular Outcomes in Hemodialysis Patients: Results from the Frequent Hemodialysis Network Study

    PubMed Central

    Unruh, Mark; Tamura, Manjula Kurella; Larive, Brett; Rastogi, Anjay; James, Sam; Schiller, Brigitte; Gassman, Jennifer; Chan, Christopher; Lockridge, Robert; Kliger, Alan

    2011-01-01

    Background Poor sleep quality is a common, persistent, and important problem to patients with end-stage renal disease (ESRD). This report examines whether sleep quality is associated with dialysis treatment factors and other modifiable clinical factors in a large group of hemodialysis (HD) patients. Methods Cross-sectional analyses were conducted on baseline data collected from participants in the Frequent Hemodialysis Network trials. Sleep quality was measured using the Medical Outcomes Study Sleep Problems Index II (SPI II), a 9-item measure of sleep quality with higher scores reflecting poorer sleep quality. Results The participants had an age of 51.2 ± 13.6 years, 61% were male, 38% were black, and 42% had diabetes. Higher pre-dialysis serum phosphorus (per 0.5 mg/ml) (OR 0.91; 95% CI 0.85, 0.96) and depression (OR 0.16; 95% CI 0.10, 0.25) were independently associated with decrements in sleep quality. There was also a difference in time to recovery from dialysis for the fourth versus the first SPI II quartile (5.1 h; p < 0.0001). Conclusion These findings underscore the link between sleep and daytime function and suggest that improving sleep may provide an opportunity to improve outcomes in ESRD. Whether sleep problems may be improved by reduction of serum phosphorus or treatment of depression in the HD population merits further investigation. PMID:21474924

  16. Quality effort decision in service supply chain with quality preference based on quantum game

    NASA Astrophysics Data System (ADS)

    Zhang, Cuihua; Xing, Peng; Wang, Jianwei

    2015-04-01

    Service quality preference behaviors of both members are considered in service supply chain (SSC) including a service integrator and a service provider with stochastic demand. Through analysis of service quality cost and revenue, the utility functions are established on service quality effort degree and service quality preference level in integrated and decentralized SSC. Nash equilibrium and quantum game are used to optimize the models. By comparing the different solutions, the optimal strategies are obtained in SSC with quality preference. Then some numerical examples are studied and the changing trend of service quality effort is further analyzed by the influence of the entanglement operator and quality preferences.

  17. Stand quality management of a water oak plantation in Louisiana: preliminary results following thinning

    Treesearch

    James S. Meadows; Daniel A., Jr. Skojac

    2010-01-01

    Stand quality management is a new guiding principle in which thinning prescriptions are based on tree quality rather than on residual stand density. We recently initiated a series of hardwood thinning studies to determine the effects of four stand quality management thinning prescriptions on both stand-level and individual-tree-level growth, quality, and value: (1) no...

  18. Linking plot, field, and watershed runoff and water quality in Goodwater Creek Experimental Watershed

    USDA-ARS?s Scientific Manuscript database

    Most water quality studies are conducted at the plot, field, or watershed scale; however, studies that integrate the three scales provide information to scale results obtained at one scale to a greater area. The objective of this study was to analyze runoff and water quality measured (1997-2001) fr...

  19. Cost-effective water quality assessment through the integration of monitoring data and modeling results

    NASA Astrophysics Data System (ADS)

    Lobuglio, Joseph N.; Characklis, Gregory W.; Serre, Marc L.

    2007-03-01

    Sparse monitoring data and error inherent in water quality models make the identification of waters not meeting regulatory standards uncertain. Additional monitoring can be implemented to reduce this uncertainty, but it is often expensive. These costs are currently a major concern, since developing total maximum daily loads, as mandated by the Clean Water Act, will require assessing tens of thousands of water bodies across the United States. This work uses the Bayesian maximum entropy (BME) method of modern geostatistics to integrate water quality monitoring data together with model predictions to provide improved estimates of water quality in a cost-effective manner. This information includes estimates of uncertainty and can be used to aid probabilistic-based decisions concerning the status of a water (i.e., impaired or not impaired) and the level of monitoring needed to characterize the water for regulatory purposes. This approach is applied to the Catawba River reservoir system in western North Carolina as a means of estimating seasonal chlorophyll a concentration. Mean concentration and confidence intervals for chlorophyll a are estimated for 66 reservoir segments over an 11-year period (726 values) based on 219 measured seasonal averages and 54 model predictions. Although the model predictions had a high degree of uncertainty, integration of modeling results via BME methods reduced the uncertainty associated with chlorophyll estimates compared with estimates made solely with information from monitoring efforts. Probabilistic predictions of future chlorophyll levels on one reservoir are used to illustrate the cost savings that can be achieved by less extensive and rigorous monitoring methods within the BME framework. While BME methods have been applied in several environmental contexts, employing these methods as a means of integrating monitoring and modeling results, as well as application of this approach to the assessment of surface water monitoring networks

  20. The Research into the Quality of Rock Surfaces Obtained by Abrasive Water Jet Cutting

    NASA Astrophysics Data System (ADS)

    Młynarczuk, Mariusz; Skiba, Marta; Sitek, Libor; Hlaváček, Petr; Kožušníková, Alena

    2014-12-01

    In recent years, water jet cutting technology has been being used more and more often, in various domains of human activity. Its numerous applications include cutting different materials - among them, rock materials. The present paper discusses the results of the research that aimed at determining - in a quantitative manner - the way in which the water jet cutting parameters (such as the traverse speed of the head, and the distance between the high-pressure inlet of the water jet and the cut material) influence the quality of the processed surface. Additionally, the impact of these parameters on the surface of various materials was investigated. The materials used were three granites differing with respect to the size of grains. In the course of the research, the standard parameters defined by the ISO norms were analyzed. It was also proposed that variograms be used to analyze the quality of the cut surface. Technologia cięcia strumieniem wodnym staje się w ostatnich latach coraz intensywniej wykorzystywana w różnych dziedzinach działalności człowieka. Jest ona wykorzystywana do obróbki różnorodnych materiałów, również materiałów skalnych. W ramach badań analizowano trzy granity różniące się m.in. wielkościami ziarn, które były przecinane przy różnych prędkościach przesuwu głowicy z wlotem strumienia wodnego. Analizowano standardowe parametry zdefiniowane w normach ISO jak również zaproponowano wykorzystanie wariogramów do analizy jakości wyciętej powierzchni. W pracy opisano w sposób ilościowy zmiany jakości powierzchni skał ciętych strumieniem wodnym ze ścierniwem w zależności od prędkości przesuwu głowicy, jak również w zależności od odległości przecinanego fragmentu powierzchni od wlotu strumienia wodnego do materiału. Wyniki uzyskane w pomiarach wskazują też na wpływ wielkości uziarnienia skały na jakość otrzymanej powierzchni. Jest to szczególnie widoczne dla najmniej optymalnych parametrów ci

  1. Implementation of basic quality control tests for malaria medicines in Amazon Basin countries: results for the 2005-2010 period.

    PubMed

    Pribluda, Victor S; Barojas, Adrian; Añez, Arletta; López, Cecilia G; Figueroa, Ruth; Herrera, Roxana; Nakao, Gladys; Nogueira, Fernando Ha; Pianetti, Gerson A; Povoa, Marinete M; Viana, Giselle Mr; Gomes, Margarete S Mendonça; Escobar, Jose P; Sierra, Olga L Muñoz; Norena, Susana P Rendon; Veloz, Raúl; Bravo, Marcy Silva; Aldás, Martha R; Hindssemple, Alison; Collins, Marilyn; Ceron, Nicolas; Krishnalall, Karanchand; Adhin, Malti; Bretas, Gustavo; Hernandez, Nelly; Mendoza, Marjorie; Smine, Abdelkrim; Chibwe, Kennedy; Lukulay, Patrick; Evans, Lawrence

    2012-06-15

    Ensuring the quality of malaria medicines is crucial in working toward malaria control and eventual elimination. Unlike other validated tests that can assess all critical quality attributes, which is the standard for determining the quality of medicines, basic tests are significantly less expensive, faster, and require less skilled labour; yet, these tests provide reproducible data and information on several critical quality attributes, such as identity, purity, content, and disintegration. Visual and physical inspection also provides valuable information about the manufacturing and the labelling of medicines, and in many cases this inspection is sufficient to detect counterfeit medicines. The Promoting the Quality of Medicines (PQM) programme has provided technical assistance to Amazon Malaria Initiative (AMI) countries to implement the use of basic tests as a key screening mechanism to assess the quality of malaria medicines available to patients in decentralized regions. Trained personnel from the National Malaria Control Programmes (NMCPs), often in collaboration with country's Official Medicine Control Laboratory (OMCL), developed country- specific protocols that encompassed sampling methods, sample analysis, and data reporting. Sampling sites were selected based on malaria burden, accessibility, and geographical location. Convenience sampling was performed and countries were recommended to store the sampled medicines under conditions that did not compromise their quality. Basic analytical tests, such as disintegration and thin layer chromatography (TLC), were performed utilizing a portable mini-laboratory. Results were originally presented at regional meetings in a non-standardized format that lacked relevant medicines information. However, since 2008 information has been submitted utilizing a template specifically developed by PQM for that purpose. From 2005 to 2010, the quality of 1,663 malaria medicines from seven AMI countries was evaluated, mostly

  2. Standardizing Quality Assessment of Fused Remotely Sensed Images

    NASA Astrophysics Data System (ADS)

    Pohl, C.; Moellmann, J.; Fries, K.

    2017-09-01

    The multitude of available operational remote sensing satellites led to the development of many image fusion techniques to provide high spatial, spectral and temporal resolution images. The comparison of different techniques is necessary to obtain an optimized image for the different applications of remote sensing. There are two approaches in assessing image quality: 1. Quantitatively by visual interpretation and 2. Quantitatively using image quality indices. However an objective comparison is difficult due to the fact that a visual assessment is always subject and a quantitative assessment is done by different criteria. Depending on the criteria and indices the result varies. Therefore it is necessary to standardize both processes (qualitative and quantitative assessment) in order to allow an objective image fusion quality evaluation. Various studies have been conducted at the University of Osnabrueck (UOS) to establish a standardized process to objectively compare fused image quality. First established image fusion quality assessment protocols, i.e. Quality with No Reference (QNR) and Khan's protocol, were compared on varies fusion experiments. Second the process of visual quality assessment was structured and standardized with the aim to provide an evaluation protocol. This manuscript reports on the results of the comparison and provides recommendations for future research.

  3. Optimal quality control of bakers' yeast fed-batch culture using population dynamics.

    PubMed

    Dairaku, K; Izumoto, E; Morikawa, H; Shioya, S; Takamatsu, T

    1982-12-01

    An optimal quality control policy for the overall specific growth rate of bakers' yeast, which maximizes the fermentative activity in the making of bread, was obtained by direct searching based on the mathematical model proposed previously. The mathematical model had described the age distribution of bakers' yeast which had an essential relationship to the ability of fermentation in the making of bread. The mathematical model is a simple aging model with two periods: Nonbudding and budding. Based on the result obtained by direct searching, the quality control of bakers' yeast fed-batch culture was performed and confirmed to be experimentally valid.

  4. Quality Assurance of Samples and Processes in the Spanish Renal Research Network (REDinREN) Biobank.

    PubMed

    Calleros-Basilio, Laura; Cortés, María Alicia; García-Jerez, Andrea; Luengo-Rodríguez, Alicia; Orozco-Agudo, Ana; Valdivielso, José Manuel; Rodríguez-Puyol, Diego; Rodríguez-Puyol, Manuel

    2016-12-01

    Biobanks are useful platforms to build bridges between basic, translational, and clinical research and clinical care. They are repositories of high-quality human biological samples ideal for evaluating their histological characteristics and also their genome, transcriptome, and proteome. The Spanish Renal Research Network Biobank contains more than 76,500 well-preserved frozen samples of a wide variety of kidney diseases, collected from 5450 patients seen by over 70 nephrology services throughout the Spanish territory. To determine and to report the results of the quality control of samples and processes conducted in our biobank, implemented in accordance with the requirements of the ISO 9001:2008 international standard. Two types of quality controls were performed: (1) systematic, that is, measurement of viable peripheral blood mononuclear cells (PBMCs) obtained and purity of nucleic acids and (2) ad-hoc, that is, viability of thawed PBMC, DNA extraction process reproducibility, and the integrity and functionality of nucleic acids, implemented on a routine basis. PBMC isolation by Ficoll yielded reproducible results and its cryopreserved viability was >90%. Acceptable A260/A280 ratios were obtained for the vast majority of the DNA (n = 2328) and RNA (n = 78) samples analyzed. DNA integrity was demonstrated by agarose gels and by β-globulin gene polymerase chain reaction (PCR) amplification of 1327 and 989 bp fragments. DNA of acceptable quality had at least three bands of β-globulin amplified obtained (n = 26/30). RNA integrity number (RIN) determinations obtained RIN numbers ≥7 (n = 87/96). The amplifiability of nucleic acids was confirmed by qPCR and RT-qPCR of β-actin and GAPDH genes. Long storage or delayed processing time did not affect the quality of the samples analyzed. The processes of DNA extraction also yielded reproducible results. These results clearly indicate that our PBMC, DNA, and RNA stored samples meet the required quality

  5. 40 CFR 60.2945 - Is there a minimum amount of operating parameter monitoring data I must obtain?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... parameter monitoring data I must obtain? 60.2945 Section 60.2945 Protection of Environment ENVIRONMENTAL... Operator Training and Qualification Monitoring § 60.2945 Is there a minimum amount of operating parameter monitoring data I must obtain? (a) Except for monitor malfunctions, associated repairs, and required quality...

  6. 40 CFR 60.2945 - Is there a minimum amount of operating parameter monitoring data I must obtain?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... parameter monitoring data I must obtain? 60.2945 Section 60.2945 Protection of Environment ENVIRONMENTAL... Operator Training and Qualification Monitoring § 60.2945 Is there a minimum amount of operating parameter monitoring data I must obtain? (a) Except for monitor malfunctions, associated repairs, and required quality...

  7. 40 CFR 60.2945 - Is there a minimum amount of operating parameter monitoring data I must obtain?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... parameter monitoring data I must obtain? 60.2945 Section 60.2945 Protection of Environment ENVIRONMENTAL... Operator Training and Qualification Monitoring § 60.2945 Is there a minimum amount of operating parameter monitoring data I must obtain? (a) Except for monitor malfunctions, associated repairs, and required quality...

  8. Probabilistic techniques for obtaining accurate patient counts in Clinical Data Warehouses

    PubMed Central

    Myers, Risa B.; Herskovic, Jorge R.

    2011-01-01

    Proposal and execution of clinical trials, computation of quality measures and discovery of correlation between medical phenomena are all applications where an accurate count of patients is needed. However, existing sources of this type of patient information, including Clinical Data Warehouses (CDW) may be incomplete or inaccurate. This research explores applying probabilistic techniques, supported by the MayBMS probabilistic database, to obtain accurate patient counts from a clinical data warehouse containing synthetic patient data. We present a synthetic clinical data warehouse (CDW), and populate it with simulated data using a custom patient data generation engine. We then implement, evaluate and compare different techniques for obtaining patients counts. We model billing as a test for the presence of a condition. We compute billing’s sensitivity and specificity both by conducting a “Simulated Expert Review” where a representative sample of records are reviewed and labeled by experts, and by obtaining the ground truth for every record. We compute the posterior probability of a patient having a condition through a “Bayesian Chain”, using Bayes’ Theorem to calculate the probability of a patient having a condition after each visit. The second method is a “one-shot” approach that computes the probability of a patient having a condition based on whether the patient is ever billed for the condition Our results demonstrate the utility of probabilistic approaches, which improve on the accuracy of raw counts. In particular, the simulated review paired with a single application of Bayes’ Theorem produces the best results, with an average error rate of 2.1% compared to 43.7% for the straightforward billing counts. Overall, this research demonstrates that Bayesian probabilistic approaches improve patient counts on simulated patient populations. We believe that total patient counts based on billing data are one of the many possible applications of our

  9. Kennedy Space Center's NASA/Contractor Team-Centered Total Quality Management Seminar: Results, methods, and lessons learned

    NASA Technical Reports Server (NTRS)

    Kinlaw, Dennis C.; Eads, Jeannette

    1992-01-01

    It is apparent to everyone associated with the Nation's aeronautics and space programs that the challenge of continuous improvement can be reasonably addressed only if NASA and its contractors act together in a fully integrated and cooperative manner that transcends the traditional boundaries of proprietary interest. It is, however, one thing to assent to the need for such integration and cooperation; it is quite another thing to undertake the hard tasks of turning such a need into action. Whatever else total quality management is, it is fundamentally a team-centered and team-driven process of continuous improvement. The introduction of total quality management at KSC, therefore, has given the Center a special opportunity to translate the need for closer integration and cooperation among all its organizations into specific initiatives. One such initiative that NASA and its contractors have undertaken at KSC is a NASA/Contractor team-centered Total Quality Management Seminar. It is this seminar which is the subject of this paper. The specific purposes of this paper are to describe the following: Background, development, and evolution of Kennedy Space Center's Total Quality Management Seminar; Special characteristics of the seminar; Content of the seminar; Meaning and utility of a team-centered design for TQM training; Results of the seminar; Use that one KSC contractor, EG&G Florida, Inc. has made of the seminar in its Total Quality Management initiative; and Lessons learned.

  10. Implementation of basic quality control tests for malaria medicines in Amazon Basin countries: results for the 2005–2010 period

    PubMed Central

    2012-01-01

    Background Ensuring the quality of malaria medicines is crucial in working toward malaria control and eventual elimination. Unlike other validated tests that can assess all critical quality attributes, which is the standard for determining the quality of medicines, basic tests are significantly less expensive, faster, and require less skilled labour; yet, these tests provide reproducible data and information on several critical quality attributes, such as identity, purity, content, and disintegration. Visual and physical inspection also provides valuable information about the manufacturing and the labelling of medicines, and in many cases this inspection is sufficient to detect counterfeit medicines. The Promoting the Quality of Medicines (PQM) programme has provided technical assistance to Amazon Malaria Initiative (AMI) countries to implement the use of basic tests as a key screening mechanism to assess the quality of malaria medicines available to patients in decentralized regions. Methods Trained personnel from the National Malaria Control Programmes (NMCPs), often in collaboration with country’s Official Medicine Control Laboratory (OMCL), developed country- specific protocols that encompassed sampling methods, sample analysis, and data reporting. Sampling sites were selected based on malaria burden, accessibility, and geographical location. Convenience sampling was performed and countries were recommended to store the sampled medicines under conditions that did not compromise their quality. Basic analytical tests, such as disintegration and thin layer chromatography (TLC), were performed utilizing a portable mini-laboratory. Results Results were originally presented at regional meetings in a non-standardized format that lacked relevant medicines information. However, since 2008 information has been submitted utilizing a template specifically developed by PQM for that purpose. From 2005 to 2010, the quality of 1,663 malaria medicines from seven AMI countries

  11. [Perceived quality in hospitals of the Andalusia Healthcare System. The case of neurosurgery departments].

    PubMed

    Cordero Tous, N; Horcajadas Almansa, Á; Bermúdez González, G J; Tous Zamora, D

    2014-01-01

    To analyse the characteristics of the perceived quality in hospitals of the Andalusia healthcare system and compare this with that in Andalusian Neurosurgery departments. Randomised surveys, adjusted for working age, were performed in Andalusia using a telephone questionnaire based on the SERVQUAL model with the appropriate modification, with the subsequent selection of a subgroup associated with neurosurgery. Perceived quality was classified as; technical, functional and infrastructure quality. The overall satisfaction was 76.3%. Frequency analysis found that variables related to the technical quality (good doctors, successful operations, trained staff, etc.) obtained more favourable outcomes. Those related to time (wait, consulting, organizing schedules) obtained worse outcomes. The care of families variables obtained poor results. There was no difference between the overall Andalusian healthcare system and neurosurgery departments. In the mean analysis, women and older people gave more favourable responses, especially for variables related to infrastructure quality. In the "cluster" analysis, there were more favourable responses by elderly people, with no differences in gender (P<.009). There is no difference in perceived quality between the Andalusian healthcare system overall and neurosurgery departments. The perceived quality of the Andalusian healthcare system is higher in the elderly people. The analysis of perceived quality is useful for promoting projects to improve clinical management. Copyright © 2014 SECA. Published by Elsevier Espana. All rights reserved.

  12. Novel indicators of recreational water quality and swimming-associated illness

    EPA Science Inventory

    In the United States and elsewhere, recreational water quality is monitored for fecal indicator bacteria to help prevent swimming-associated illnesses. Standard methods to measure these bacteria take at least 24 hours to obtain results. Molecular approaches such as quantitative p...

  13. Quality Assessment of Studies Published in Open Access and Subscription Journals: Results of a Systematic Evaluation

    PubMed Central

    Pastorino, Roberta; Milovanovic, Sonja; Stojanovic, Jovana; Efremov, Ljupcho; Amore, Rosarita; Boccia, Stefania

    2016-01-01

    Introduction Along with the proliferation of Open Access (OA) publishing, the interest for comparing the scientific quality of studies published in OA journals versus subscription journals has also increased. With our study we aimed to compare the methodological quality and the quality of reporting of primary epidemiological studies and systematic reviews and meta-analyses published in OA and non-OA journals. Methods In order to identify the studies to appraise, we listed all OA and non-OA journals which published in 2013 at least one primary epidemiologic study (case-control or cohort study design), and at least one systematic review or meta-analysis in the field of oncology. For the appraisal, we picked up the first studies published in 2013 with case-control or cohort study design from OA journals (Group A; n = 12), and in the same time period from non-OA journals (Group B; n = 26); the first systematic reviews and meta-analyses published in 2013 from OA journals (Group C; n = 15), and in the same time period from non-OA journals (Group D; n = 32). We evaluated the methodological quality of studies by assessing the compliance of case-control and cohort studies to Newcastle and Ottawa Scale (NOS) scale, and the compliance of systematic reviews and meta-analyses to Assessment of Multiple Systematic Reviews (AMSTAR) scale. The quality of reporting was assessed considering the adherence of case-control and cohort studies to STrengthening the Reporting of OBservational studies in Epidemiology (STROBE) checklist, and the adherence of systematic reviews and meta-analyses to Preferred Reporting Items for Systematic reviews and Meta-Analysis (PRISMA) checklist. Results Among case-control and cohort studies published in OA and non-OA journals, we did not observe significant differences in the median value of NOS score (Group A: 7 (IQR 7–8) versus Group B: 8 (7–9); p = 0.5) and in the adherence to STROBE checklist (Group A, 75% versus Group B, 80%; p = 0.1). The

  14. Semen quality of young adult ICSI offspring: the first results.

    PubMed

    Belva, F; Bonduelle, M; Roelants, M; Michielsen, D; Van Steirteghem, A; Verheyen, G; Tournaye, H

    2016-12-01

    What is the semen quality of young adult men who were conceived 18-22 years ago by ICSI for male infertility? In this cohort of 54 young adult ICSI men, median sperm concentration, total sperm count and total motile sperm count were significantly lower than in spontaneously conceived peers. The oldest ICSI offspring cohort worldwide has recently reached adulthood. Hence, their reproductive health can now be investigated. Since these children were conceived by ICSI because of severe male-factor infertility, there is reasonable concern that male offspring have inherited the deficient spermatogenesis from their fathers. Previously normal pubertal development and adequate Sertoli and Leydig cell function have been described in pubertal ICSI boys; however, no information on their sperm quality is currently available. This study was conducted at UZ Brussel between March 2013 and April 2016 and is part of a large follow-up project focussing on reproductive and metabolic health of young adults, between 18 and 22 years and conceived after ICSI with ejaculated sperm. Results of both a physical examination and semen analysis were compared between young ICSI men being part of a longitudinally followed cohort and spontaneously conceived controls who were recruited cross-sectionally. Results of a single semen sample in 54 young adult ICSI men and 57 spontaneously conceived men are reported. All young adults were individually assessed, and the results of their physical examination were completed by questionnaires. Data were analysed by multiple linear and logistic regression, adjusted for covariates. In addition, semen parameters of the ICSI fathers dating back from their ICSI treatment application were analysed for correlations. Young ICSI adults had a lower median sperm concentration (17.7 million/ml), lower median total sperm count (31.9 million) and lower median total motile sperm count (12.7 million) in comparison to spontaneously conceived peers (37.0 million/ml; 86

  15. The impact of the condenser on cytogenetic image quality in digital microscope system.

    PubMed

    Ren, Liqiang; Li, Zheng; Li, Yuhua; Zheng, Bin; Li, Shibo; Chen, Xiaodong; Liu, Hong

    2013-01-01

    Optimizing operational parameters of the digital microscope system is an important technique to acquire high quality cytogenetic images and facilitate the process of karyotyping so that the efficiency and accuracy of diagnosis can be improved. This study investigated the impact of the condenser on cytogenetic image quality and system working performance using a prototype digital microscope image scanning system. Both theoretical analysis and experimental validations through objectively evaluating a resolution test chart and subjectively observing large numbers of specimen were conducted. The results show that the optimal image quality and large depth of field (DOF) are simultaneously obtained when the numerical aperture of condenser is set as 60%-70% of the corresponding objective. Under this condition, more analyzable chromosomes and diagnostic information are obtained. As a result, the system shows higher working stability and less restriction for the implementation of algorithms such as autofocusing especially when the system is designed to achieve high throughput continuous image scanning. Although the above quantitative results were obtained using a specific prototype system under the experimental conditions reported in this paper, the presented evaluation methodologies can provide valuable guidelines for optimizing operational parameters in cytogenetic imaging using the high throughput continuous scanning microscopes in clinical practice.

  16. Two methods for proteomic analysis of formalin-fixed, paraffin embedded tissue result in differential protein identification, data quality, and cost.

    PubMed

    Luebker, Stephen A; Wojtkiewicz, Melinda; Koepsell, Scott A

    2015-11-01

    Formalin-fixed paraffin-embedded (FFPE) tissue is a rich source of clinically relevant material that can yield important translational biomarker discovery using proteomic analysis. Protocols for analyzing FFPE tissue by LC-MS/MS exist, but standardization of procedures and critical analysis of data quality is limited. This study compared and characterized data obtained from FFPE tissue using two methods: a urea in-solution digestion method (UISD) versus a commercially available Qproteome FFPE Tissue Kit method (Qkit). Each method was performed independently three times on serial sections of homogenous FFPE tissue to minimize pre-analytical variations and analyzed with three technical replicates by LC-MS/MS. Data were evaluated for reproducibility and physiochemical distribution, which highlighted differences in the ability of each method to identify proteins of different molecular weights and isoelectric points. Each method replicate resulted in a significant number of new protein identifications, and both methods identified significantly more proteins using three technical replicates as compared to only two. UISD was cheaper, required less time, and introduced significant protein modifications as compared to the Qkit method, which provided more precise and higher protein yields. These data highlight significant variability among method replicates and type of method used, despite minimizing pre-analytical variability. Utilization of only one method or too few replicates (both method and technical) may limit the subset of proteomic information obtained. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Willingness to pay per quality-adjusted life year: is one threshold enough for decision-making?: results from a study in patients with chronic prostatitis.

    PubMed

    Zhao, Fei-Li; Yue, Ming; Yang, Hua; Wang, Tian; Wu, Jiu-Hong; Li, Shu-Chuen

    2011-03-01

    To estimate the willingness to pay (WTP) per quality-adjusted life year (QALY) ratio with the stated preference data and compare the results obtained between chronic prostatitis (CP) patients and general population (GP). WTP per QALY was calculated with the subjects' own health-related utility and the WTP value. Two widely used preference-based health-related quality of life instruments, EuroQol (EQ-5D) and Short Form 6D (SF-6D), were used to elicit utility for participants' own health. The monthly WTP values for moving from participants' current health to a perfect health were elicited using closed-ended iterative bidding contingent valuation method. A total of 268 CP patients and 364 participants from GP completed the questionnaire. We obtained 4 WTP/QALY ratios ranging from $4700 to $7400, which is close to the lower bound of local gross domestic product per capita, a threshold proposed by World Health Organization. Nevertheless, these values were lower than other proposed thresholds and published empirical researches on diseases with mortality risk. Furthermore, the WTP/QALY ratios from the GP were significantly lower than those from the CP patients, and different determinants were associated with the within group variation identified by multiple linear regression. Preference elicitation methods are acceptable and feasible in the socio-cultural context of an Asian environment and the calculation of WTP/QALY ratio produced meaningful answers. The necessity of considering the QALY type or disease-specific QALY in estimating WTP/QALY ratio was highlighted and 1 to 3 times of gross domestic product/capita recommended by World Health Organization could potentially serve as a benchmark for threshold in this Asian context.

  18. Identifying Consistent and Coherent Dimensions of Nursing Home Quality: Exploratory Factor Analysis of Quality Indicators.

    PubMed

    Xu, Dongjuan; Kane, Robert L; Shippee, Tetyana; Lewis, Teresa M

    2016-12-01

    There is a general belief that the markers of nursing home quality do not aggregate easily. Identifying consistent and coherent dimensions of quality that usefully summarize the multiplicity of nursing home quality measures is an important goal. It would simplify interpretation and help consumers, their families and advocates to choose nursing facilities. This study uses quality indicators (QIs) from a state nursing home report card to explore the dimensionality of quality in nursing homes and to determine whether aggregation at the resident versus facility level yields the same underlying dimensions. Cross-sectional study. 382 Medicare- and/or Medicaid-certified nursing homes in Minnesota. Residents admitted to the nursing homes during 2011-2012. 16 QIs obtained from the Minimum Data Set 3.0 assessment instrument between 2011 and 2012 were used in the exploratory factor analysis. Factor analysis results suggest four main factors or dimensions to characterize facility performance: continence care (including 4 QIs), restraints and behavioral symptoms (including 3 QIs), care for specific conditions (including 6 QIs), and physical functioning (including 3 QIs). The resident-level and facility-level results generally agreed for 11 QIs. Nursing home quality of care can be captured in summary measures, which can be used by consumers, providers and researchers. Reporting at the resident or facility level will depend on the purpose. These summary measures can be used by policy-makers to identify and reward high-performing facilities and by families to choose nursing facilities for care. © 2016, Copyright the Authors Journal compilation © 2016, The American Geriatrics Society.

  19. Packaging and Labeling of Pharmaceutical Products Obtained from the Internet

    PubMed Central

    2011-01-01

    Background For patients, the prescription container label may be the only source of instructions on how to take their medicines. In the United States, the legal requirements for a prescription label are set by federal law and state statutes. The container should be comparable to that which manufacturers use to package drug products and should preserve a product’s identity, strength, quality, and purity and prevent contamination. Safety features such as a child-resistant closure should be provided. Pharmaceutical products purchased from international online pharmacies are not approved by the Food and Drug Administration (FDA) and may not meet US guidelines for labeling and packaging. Objective The study objective was to determine whether commonly purchased pharmaceutical products obtained from international online pharmacies are comparable to products dispensed in the United States with regard to labeling and packaging. Methods During March 2006 through January 2007, 41 pharmaceutical oral dosage form samples were obtained from international Internet pharmacy websites for evaluation: 18 generic simvastatin samples, 18 generic amlodipine samples, and 5 generic sildenafil samples. Contents for each package were observed and recorded and comparison of the prescription labeling and packaging of these products was made with prescription labeling and packaging requirements in the United States. Results Of the 41 drug products obtained from online pharmacies from 12 different countries, only 1 product (from Canada) would meet both labeling and packaging guidelines for products dispensed in the United States. Of those not meeting the requirements, 7 were dispensed in paper envelopes with label affixed that was either handwritten or typed and contained missing information such as name and address of dispenser, name of prescriber, name of patient, and directions for use. Another 3 products did not have a label affixed to the drug product, but information was printed on a

  20. [Effect of increased protein content on nutritional and sensory quality of cookies].

    PubMed

    Pérez, Santiago Rafael; Osella, Carlos Alberto; Torre, Maria Adela de la; Sánchez, Hugo Diego

    2008-12-01

    The objective of this work was to study the effect of soy flour and whey protein concentrate (WPC) on cookies quality. An optimal recipe showing improved protein quality and content as well as acceptable sensory quality was defined taking into account the results obtained. Rotary moulded cookie formulation adaptable to lamination and cutting in pilot plant was used. Wheat flour from this formulation was partially replaced by whey protein concentrate and full fat soy flour. Second order models were employed to generate response surfaces for: total protein, lysine by 16 grams of total nitrogen, lysine by 100 grams of sample, loss of lysine during processing and sensory evaluation of cookies. We could obtain an effect on available lysine value when water content was increased in the formulation because a delay in the Maillard reaction. The optimal formulation contains 13% of full fat soy flour, 3% of whey protein concentrate and 23% of water. The results demonstrated that the protein content and the protein quality of the supplemented flours were increased when soy flour was added in the formulation of cookies. On other hand, protein content was increased but protein quality was decreased when WPC was used, because of available lysine loss.

  1. Evaluation of Aesthetic and Quality-of-Life Results after Immediate Breast Reconstruction with Definitive Form-Stable Anatomical Implants.

    PubMed

    Kuroda, Flavia; Urban, Cicero; Zucca-Matthes, Gustavo; de Oliveira, Vilmar Marques; Arana, Gabriel Hubner; Iera, Marco; Rietjens, Mario; Santos, Gabriela; Spagnol, Caroline; de Lima, Rubens Silveira

    2016-02-01

    Although there are many reports on different techniques in breast reconstruction, there are few data regarding immediate breast reconstruction with definitive form-stable anatomical implants in terms of aesthetics and quality-of-life outcomes. Ninety-four patients underwent mastectomy with immediate breast reconstruction using anatomical implants and contralateral symmetrization. Aesthetic results were evaluated by three different methods: the patient's self-report, the assessment of four independent specialists (two breast surgeons and two plastic surgeons from different institutions), and the BCCT.core software. Quality of life was evaluated by means of the BREAST-Q instrument. Average age ± SD was 52.1 ± 11.6 years. Most of patients had medium size breasts and T1 tumors. Patients had evaluated their aesthetic results better than did software and specialists. There was no significant difference in the comparison between software and specialist's evaluation. Multifactorial analysis showed that age older than 70 years and radiotherapy were significant risk factors for poor aesthetic outcomes after immediate breast reconstruction with implants. Considering quality of life, most of the patients were satisfied with their outcome and psychosocial and sexual well-being. Immediate breast reconstruction with implants and contralateral symmetrization had a positive impact on the quality of life and showed satisfactory outcomes when evaluated by subjective and objective methods.

  2. External bone marrow cytological examination quality assurance (EQAhem)--summary after 6 years in Poland.

    PubMed

    Lewandowski, Krzysztof; Kurpierz, Katarzyna; Sledzinska, Anna

    2015-10-01

    Bone marrow macroscopic examination remains one of the most difficult and subjective laboratory assessments in hematology. Only a few external quality assurance programs in the field are present worldwide. We have developed an external quality assurance program EQAhem that allows assessment of the whole process of bone marrow examination. The program participants assess blood and bone marrow smears from the patient, identify selected cells from photographs provided to them, and interpret the microscopic results. In this article, the results of the EQAhem program in Poland from 6 years are summarized. During this time, 62 labs were assessed in total, and positive results were achieved by 89.25 % labs, taking into account all tests. Correct responses with respect to the percentage of cell count were provided by ca. 77.5 % labs. Slightly worse results were obtained when megakaryocyte count and cell identification from photographs were tested. The worst results were obtained in case of dysplasia assessment and clinical interpretation of microscopic examination (54.1 and 58.6 % correct responses, respectively). EQAhem delivers precise information about the quality of bone marrow examinations performed in Poland and has a substantial educational value. We believe that after 6 years, EQAhem has significantly improved the quality of bone marrow microscopic examinations performed in Poland.

  3. Groundwater-Quality Data in the Antelope Valley Study Unit, 2008: Results from the California GAMA Program

    USGS Publications Warehouse

    Schmitt, Stephen J.; Milby Dawson, Barbara J.; Belitz, Kenneth

    2009-01-01

    -control samples (blanks, replicates, and samples for matrix spikes) were collected at 12 percent of the wells, and the results for these samples were used to evaluate the quality of the data for the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a noticeable source of bias in the data for the groundwater samples. Differences between replicate samples generally were within acceptable ranges, indicating acceptably low variability. Matrix spike recoveries were within acceptable ranges for most compoundsThis study did not evaluate the quality of water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to raw groundwater. However, to provide some context for the results, concentrations of constituents measured in the raw groundwater were compared with regulatory and non-regulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH) and thresholds established for aesthetic concerns (secondary maximum contaminant levels, SMCL-CA) by CDPH. Comparisons between data collected for this study and drinking-water thresholds are for illustrative purposes only, and are not indicative of compliance or non-compliance with drinking water standards. Most constituents that were detected in groundwater samples were found at concentrations below drinking-water thresholds. Volatile organic compounds (VOCs) were detected in about one-half of the samples and pesticides detected in about one-third of the samples; all detections of these constituents were below health-based thresholds. Most detections of trace elements and nutrients in samples from ANT wells were below health-based thresholds. Exceptions include: one detection of nitrite plus nitr

  4. Evaluation of Observation-Fused Regional Air Quality Model Results for Population Air Pollution Exposure Estimation

    PubMed Central

    Chen, Gang; Li, Jingyi; Ying, Qi; Sherman, Seth; Perkins, Neil; Rajeshwari, Sundaram; Mendola, Pauline

    2014-01-01

    In this study, Community Multiscale Air Quality (CMAQ) model was applied to predict ambient gaseous and particulate concentrations during 2001 to 2010 in 15 hospital referral regions (HRRs) using a 36-km horizontal resolution domain. An inverse distance weighting based method was applied to produce exposure estimates based on observation-fused regional pollutant concentration fields using the differences between observations and predictions at grid cells where air quality monitors were located. Although the raw CMAQ model is capable of producing satisfying results for O3 and PM2.5 based on EPA guidelines, using the observation data fusing technique to correct CMAQ predictions leads to significant improvement of model performance for all gaseous and particulate pollutants. Regional average concentrations were calculated using five different methods: 1) inverse distance weighting of observation data alone, 2) raw CMAQ results, 3) observation-fused CMAQ results, 4) population-averaged raw CMAQ results and 5) population-averaged fused CMAQ results. It shows that while O3 (as well as NOx) monitoring networks in the HRR regions are dense enough to provide consistent regional average exposure estimation based on monitoring data alone, PM2.5 observation sites (as well as monitors for CO, SO2, PM10 and PM2.5 components) are usually sparse and the difference between the average concentrations estimated by the inverse distance interpolated observations, raw CMAQ and fused CMAQ results can be significantly different. Population-weighted average should be used to account spatial variation in pollutant concentration and population density. Using raw CMAQ results or observations alone might lead to significant biases in health outcome analyses. PMID:24747248

  5. [Feasibility and results of the short Diet Quality Screener in Primary Care: EMAP study].

    PubMed

    Ríos-Rodríguez, María de Los Ángeles; García-Cerdán, María Rosa; Calonge-Vallejo, Ana Rosa; Tobella-Andreu, Laia; Baena-Díez, José Miguel; Schröder, Helmut

    To study the feasibility and results of the self-reported short diet quality screener (sDQS) in Primary Care. The variables associated with difficulty and inadequate diet are also determined. Cross-sectional descriptive study conducted with 196 participants aged >18 years with diabetes mellitus, hypertension, or hypercholesterolaemia, consecutively included from 4 Primary Health Care Centres in Barcelona. The main variables collected were, age, sex, educational level, cardiovascular risk factors, body mass index, time to complete the sDQS, degree of difficulty, and diet score: inadequate diet ≤18, adequate in some aspects 19-27, adequate >27. The mean age was 48.8 years (52% males). The analysis of the variables showed that the prevalence of having higher than a primary education level, hypertension, diabetes, hypercholesterolemia, and obesity was 50%, 54.6%, 23.5%, 56.6%, and 27.5%, respectively. The mean time to complete the questionnaire was 2.3min. More than 80% considered it easy or very easy. An inadequate diet was reported by 21.4%, adequate in some aspects by 76.5%, and an adequate diet only by 2%. To be older than 49 years and a low diet quality increased the risk of needing ≥2min to complete the sDQS (OR 2.0, 95% CI; 1.0-4.3, and OR 2.3, 95% CI; 1.1-5.1, respectively). Not following a low cholesterol diet and age less than 49 years increased the risk of a low diet quality (OR 2.2; 95% CI: 1.1-4.5, and OR 2.9; 95% CI: 1.2-6.8, respectively). The completion of the sDQS is easy and was not a significant time-burden in Primary Care. A significant proportion of participants with cardiovascular risk reported a low diet quality. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  6. Quality-assurance results for routine water analyses in U.S. Geological Survey laboratories, water year 1998

    USGS Publications Warehouse

    Ludtke, Amy S.; Woodworth, Mark T.; Marsh, Philip S.

    2000-01-01

    The U.S. Geological Survey operates a quality-assurance program based on the analyses of reference samples for two laboratories: the National Water Quality Laboratory and the Quality of Water Service Unit. Reference samples that contain selected inorganic, nutrient, and low-level constituents are prepared and submitted to the laboratory as disguised routine samples. The program goal is to estimate precision and bias for as many analytical methods offered by the participating laboratories as possible. Blind reference samples typically are submitted at a rate of 2 to 5 percent of the annual environmental-sample load for each constituent. The samples are distributed to the laboratories throughout the year. The reference samples are subject to the identical laboratory handling, processing, and analytical procedures as those applied to environmental samples and, therefore, have been used as an independent source to verify bias and precision of laboratory analytical methods and ambient water-quality measurements. The results are stored permanently in the National Water Information System and the Blind Sample Project's data base. During water year 1998, 95 analytical procedures were evaluated at the National Water Quality Laboratory and 63 analytical procedures were evaluated at the Quality of Water Service Unit. An overall evaluation of the inorganic and low-level constituent data for water year 1998 indicated 77 of 78 analytical procedures at the National Water Quality Laboratory met the criteria for precision. Silver (dissolved, inductively coupled plasma-mass spectrometry) was determined to be imprecise. Five of 78 analytical procedures showed bias throughout the range of reference samples: chromium (dissolved, inductively coupled plasma-atomic emission spectrometry), dissolved solids (dissolved, gravimetric), lithium (dissolved, inductively coupled plasma-atomic emission spectrometry), silver (dissolved, inductively coupled plasma-mass spectrometry), and zinc

  7. Results from CrIS-ATMS Obtained Using the AIRS Science Team Retrieval Methodology

    NASA Technical Reports Server (NTRS)

    Susskind, Joel; Kouvaris, Louis C.; Iredell, Lena

    2013-01-01

    which significantly improved results of AIRS Version-6. Version-5.70 CrIS/ATMS temperature profile and surface skin temperature retrievals are of very good quality, and are better than AIRS Version-5 retrievals, but are still significantly poorer than those of AIRS Version-6. CrIS/ATMS retrievals should improve when a Neural-Net start-up system is ready for use. We also examined CrIS/ATMS retrievals generated by NOAA using their NUCAPS retrieval algorithm, which is based on earlier versions of the AIRS Science Team retrieval algorithms. We show that the NUCAPS algorithm as currently configured is not well suited for climate monitoring purposes.

  8. A methodology model for quality management in a general hospital.

    PubMed

    Stern, Z; Naveh, E

    1997-01-01

    A reappraisal is made of the relevance of industrial modes of quality management to the issues of medical care. Analysis of the nature of medical care, which differentiates it from the supplier-client relationships of industry, presents the main intrinsic characteristics, which create problems in application of the industrial quality management approaches to medical care. Several examples are the complexity of the relationship between the medical action and the result obtained, the client's nonacceptance of economic profitability as a value in his medical care, and customer satisfaction biased by variable standards of knowledge. The real problems unique to hospitals are addressed, and a methodology model for their quality management is offered. Included is a sample of indicator vectors, measurements of quality care, cost of medical care, quality of service, and human resources. These are based on the trilogy of planning quality, quality control, and improving quality. The conclusions confirm the inadequacy of industrial quality management approaches for medical institutions and recommend investment in formulation of appropriate concepts.

  9. Shift Work and Sleep Quality Among Urban Police Officers

    PubMed Central

    Fekedulegn, Desta; Burchfiel, Cecil M.; Charles, Luenda E.; Hartley, Tara A.; Andrew, Michael E.; Violanti, John M.

    2016-01-01

    Objective The aim of the study was to examine association of shift work with sleep quality in police officers. Methods Data were obtained from the Buffalo Cardio-Metabolic Occupational Police Stress study (n =363). An electronic work history database was used to define shift as day, afternoon, or night for three durations: past month, 1 year, and 15 years. Sleep quality was determined using the Pittsburgh Sleep Quality Index. Results The overall prevalence of poor sleep quality was 54%; 44% for day, 60% for afternoon, and 69% for night shift. Poor sleep quality was 70% more prevalent among night-shift officers (P <0.001) and 49% higher among those on the afternoon shift (P =0.003) relative to officers working on the day shift. Conclusions Night and evening work schedules are associated with elevated prevalence of poor sleep quality among police officers. PMID:26949891

  10. Ground-Water Quality Data in the Southern Sacramento Valley, California, 2005 - Results from the California GAMA Program

    USGS Publications Warehouse

    Milby Dawson, Barbara J.; Bennett, George L.; Belitz, Kenneth

    2008-01-01

    ) were collected at ten percent of the wells, and the results for these samples were used to evaluate the quality of the data for the ground-water samples. Assessment of the quality-control data resulted in censoring of less than 0.03 percent of the analyses of ground-water samples. This study did not evaluate the quality of water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, and (or) blended with other waters to maintain acceptable water quality. Regulatory thresholds apply to treated water that is served to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Health Services (CADHS) (Maximum Contaminant Levels [MCLs], notification levels [NLs], or lifetime health advisories [HA-Ls]) and thresholds established for aesthetic concerns (Secondary Maximum Contaminant Levels [SMCLs]). All wells were sampled for organic constituents and selected general water quality parameters; subsets of wells were sampled for inorganic constituents, nutrients, and radioactive constituents. Volatile organic compounds were detected in 49 out of 83 wells sampled and pesticides were detected in 35 out of 82 wells; all detections were below health-based thresholds, with the exception of 1 detection of 1,2,3-trichloropropane above a NL. Of the 43 wells sampled for trace elements, 27 had no detections of a trace element above a health-based threshold and 16 had at least one detection above. Of the 18 trace elements with health-based thresholds, 3 (arsenic, barium, and boron) were detected at concentrations higher an MCL. Of the 43 wells sampled for nitrate, only 1 well had a detection above the MCL. Twenty wells were sampled for radioactive constituents; only 1 (radon-222) was measured at activiti

  11. A deterministic aggregate production planning model considering quality of products

    NASA Astrophysics Data System (ADS)

    Madadi, Najmeh; Yew Wong, Kuan

    2013-06-01

    Aggregate Production Planning (APP) is a medium-term planning which is concerned with the lowest-cost method of production planning to meet customers' requirements and to satisfy fluctuating demand over a planning time horizon. APP problem has been studied widely since it was introduced and formulated in 1950s. However, in several conducted studies in the APP area, most of the researchers have concentrated on some common objectives such as minimization of cost, fluctuation in the number of workers, and inventory level. Specifically, maintaining quality at the desirable level as an objective while minimizing cost has not been considered in previous studies. In this study, an attempt has been made to develop a multi-objective mixed integer linear programming model that serves those companies aiming to incur the minimum level of operational cost while maintaining quality at an acceptable level. In order to obtain the solution to the multi-objective model, the Fuzzy Goal Programming approach and max-min operator of Bellman-Zadeh were applied to the model. At the final step, IBM ILOG CPLEX Optimization Studio software was used to obtain the experimental results based on the data collected from an automotive parts manufacturing company. The results show that incorporating quality in the model imposes some costs, however a trade-off should be done between the cost resulting from producing products with higher quality and the cost that the firm may incur due to customer dissatisfaction and sale losses.

  12. Improving the quality of healthcare for children: implementing the results of the AHSR research agenda conference.

    PubMed Central

    Halfon, N; Schuster, M; Valentine, W; McGlynn, E

    1998-01-01

    OBJECTIVE: To describe the rationale, development, content, and results of the AHSR-sponsored conference on developing a research agenda focused on improving the quality of care for children. DATA SOURCES AND METHODS: Planning documents, background papers, and conference proceedings. PRINCIPAL FINDINGS: The conference developed the research agenda focused on (1) monitoring the health of children; (2) evaluating the efficacy and effectiveness of health services for children; (3) assessing the quality of healthcare provided to children; (4) improving the quality of healthcare within health systems; (5) assessing the performance of community systems for children; (6) exploring the impact of different financial incentives on the provision of pediatric healthcare; and (7) developing and disseminating clinical practice guidelines and other information to physicians, families, and consumers. Specific issues and research questions in each area are also presented. Strategies for implementing the research agenda are presented and include: (1) expanding the child health services research workforce; (2) developing child healthcare quality improvement research centers; (3) conducting research in specific high-priority areas; (4) focusing research on improving the health of vulnerable populations; (5) improving child health data and collection systems at the national level; (6) developing better community health monitoring for children; (7) building and supporting research networks and a consortium of research users; and (8) developing a coordinated interagency federal effort to advance this agenda and to provide accountability for its completion. CONCLUSION: The proposed research agenda should be a national priority so that all Americans can be assured that children are receiving the best quality of care that the United States can provide. PMID:9776945

  13. The similia principle: results obtained in a cellular model system.

    PubMed

    Wiegant, Fred; Van Wijk, Roeland

    2010-01-01

    This paper describes the results of a research program focused on the beneficial effect of low dose stress conditions that were applied according to the similia principle to cells previously disturbed by more severe stress conditions. In first instance, we discuss criteria for research on the similia principle at the cellular level. Then, the homologous ('isopathic') approach is reviewed, in which the initial (high dose) stress used to disturb cellular physiology and the subsequent (low dose) stress are identical. Beneficial effects of low dose stress are described in terms of increased cellular survival capacity and at the molecular level as an increase in the synthesis of heat shock proteins (hsps). Both phenomena reflect a stimulation of the endogenous cellular self-recovery capacity. Low dose stress conditions applied in a homologous approach stimulate the synthesis of hsps and enhance survival in comparison with stressed cells that were incubated in the absence of low dose stress conditions. Thirdly, the specificity of the low dose stress condition is described where the initial (high dose) stress is different in nature from the subsequently applied (low dose) stress; the heterologous or 'heteropathic' approach. The results support the similia principle at the cellular level and add to understanding of how low dose stress conditions influence the regulatory processes underlying self-recovery. In addition, the phenomenon of 'symptom aggravation' which is also observed at the cellular level, is discussed in the context of self-recovery. Finally, the difference in efficiency between the homologous and the heterologous approach is discussed; a perspective is indicated for further research; and the relationship between studies on the similia principle and the recently introduced concept of 'postconditioning hormesis' is emphasized. Copyright 2009 The Faculty of Homeopathy. Published by Elsevier Ltd. All rights reserved.

  14. Development and flight test results of an autothrottle control system at Mach 3 cruise

    NASA Technical Reports Server (NTRS)

    Gilyard, G. B.; Burken, J. J.

    1980-01-01

    Flight test results obtained with the original Mach hold autopilot designed the YF-12C airplane which uses elevator control and a newly developed Mach hold system having an autothrottle integrated with an altitude hold autopilot system are presented. The autothrottle tests demonstrate good speed control at high Mach numbers and high altitudes while simultaneously maintaining control over altitude and good ride qualities. The autothrottle system was designed to control either Mach number or knots equivalent airspeed (KEAS). Excellent control of Mach number or KEAS was obtained with the autothrottle system when combined with altitude hold. Ride qualities were significantly better than with the conventional Mach hold system.

  15. Evaluation of CALGRID using two different ozone episodes and comparison to UAM results

    NASA Astrophysics Data System (ADS)

    Kumar, Naresh; Russell, Armistead G.; Tesche, Thomas W.; McNally, Dennis E.

    Air quality models serve as the foundation for policy decisions regarding programs designed to improve air quality. The California Air Resources Board Airshed Model (CALGRID) is one of the latest photochemical air quality models developed for assessing ozone control strategies. CALGRID was modified to include the lates CBIV chemical mechanism in place of the original SAPRC mechanism. After modification, a detailed evaluation of CALGRID was carried out using two different ozone episodes. The first evaluation used data obtained during the Southern California Air Quality Study (SCAQS). The second evaluation used data obtained for the September, 1984 SCCCAMP episodes in the South Central Coast Air Basin (SCCAB). Model results were compared against observations of O 3, NO, NO 2, and different organic compounds. For the SCCAB episode, the results were also compared with those obtained from the Urban Airshed Model (UAM). Similar to other studies, the ozone predictions from the SCAQS application were biased low, as were various ROG components. The reason for this can be linked to the under-representation of ROG and CO in the emissions inventory. For the SCCAB episode, both the UAM and CALGRID models significantly underestimated NO and NO 2 concentrations. The two models slightly underestimated ozone concentrations above approximately 9 pphm on the third and last day of the simulation. Sensitivity experiments were performed for both the studies. It was found that both CALGRID and UAM are strongly sensitive to the boundary conditions and moderately sensitive to the emissions for the episodes modeled.

  16. Quality and matching performance analysis of three-dimensional unraveled fingerprints

    NASA Astrophysics Data System (ADS)

    Wang, Yongchang; Hao, Qi; Fatehpuria, Abhishika; Hassebrook, Laurence G.; Lau, Daniel L.

    2010-07-01

    The use of fingerprints as a biometric is both the oldest mode of computer-aided personal identification and the most-relied-on technology in use today. However, current acquisition methods have some challenging and peculiar difficulties. For higher performance fingerprint data acquisition and verification, a novel noncontact 3-D fingerprint scanner is investigated, where both the detailed 3-D and albedo information of the finger is obtained. The obtained high-resolution 3-D prints are further converted into 3-D unraveled prints, to be compatible with traditional 2-D automatic fingerprint identification systems. As a result, many limitations imposed on conventional fingerprint capture and processing can be reduced by the unobtrusiveness of this approach and the extra depth information acquired. To compare the quality and matching performances of 3-D unraveled with traditional 2-D plain fingerprints, we collect both 3-D prints and their 2-D plain counterparts. The print quality and matching performances are evaluated and analyzed by using National Institute of Standard Technology fingerprint software. Experimental results show that the 3-D unraveled print outperforms the 2-D print in both quality and matching performances.

  17. Ground-Water Quality Data in the Southern Sierra Study Unit, 2006 - Results from the California GAMA Program

    USGS Publications Warehouse

    Fram, Miranda S.; Belitz, Kenneth

    2007-01-01

    Ground-water quality in the approximately 1,800 square-mile Southern Sierra study unit (SOSA) was investigated in June 2006 as part of the Statewide Basin Assessment Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Statewide Basin Assessment Project was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The Southern Sierra study was designed to provide a spatially unbiased assessment of raw ground-water quality within SOSA, as well as a statistically consistent basis for comparing water quality throughout California. Samples were collected from fifty wells in Kern and Tulare Counties. Thirty-five of the wells were selected using a randomized grid-based method to provide statistical representation of the study area, and fifteen were selected to evaluate changes in water chemistry along ground-water flow paths. The ground-water samples were analyzed for a large number of synthetic organic constituents [volatile organic compounds (VOCs), pesticides and pesticide degradates, pharmaceutical compounds, and wastewater-indicator compounds], constituents of special interest [perchlorate, N-nitrosodimethylamine (NDMA), and 1,2,3-trichloropropane (1,2,3-TCP)], naturally occurring inorganic constituents [nutrients, major and minor ions, and trace elements], radioactive constituents, and microbial indicators. Naturally occurring isotopes [tritium, and carbon-14, and stable isotopes of hydrogen and oxygen in water], and dissolved noble gases also were measured to help identify the source and age of the sampled ground water. Quality-control samples (blanks, replicates, and samples for matrix spikes) were collected for approximately one-eighth of the wells, and the results for these samples were used to evaluate the quality of the data for the ground-water samples. Assessment of the

  18. Assuring Quality in Education Evaluation.

    ERIC Educational Resources Information Center

    Trochim, William M. K.; Visco, Ronald J.

    1986-01-01

    A number of quality assurance educational evaluation methods are illustrated. Evaluation data obtained from the Providence, Rhode Island, school district are used. The methods are: (1) from auditing, internal control; (2) from accounting, double bookkeeping; and (3) from industrial quality control, acceptance sampling and cumulative percentage…

  19. Scientific results obtained by the Busot observatory

    NASA Astrophysics Data System (ADS)

    García-Lozano, R.; Rodes, J. J.; Torrejón, J. M.; Bernabéu, G.; Berná, J. Á.

    2016-12-01

    We present the discovery of three new W UMa systems by our group as a part of a photometric follow-up of variable stars carried out with the Busot observatory 36 cm robotic telescope in collaboration with the X-ray astronomy group at University of Alicante (Alicante, Spain). Specifically we show the high limiting magnitude to detect moving objects (V˜ 21 mag), and the high stability and accuracy attained in photometry which allow us to measure very shallow planet transits.

  20. Delivering high-quality family planning services in crisis-affected settings II: results.

    PubMed

    Curry, Dora Ward; Rattan, Jesse; Huang, Shuyuan; Noznesky, Elizabeth

    2015-02-04

    An estimated 43 million women of reproductive age experienced the effects of conflict in 2012. Already vulnerable from the insecurity of the emergency, women must also face the continuing risk of unwanted pregnancy but often are unable to obtain family planning services. The ongoing Supporting Access to Family Planning and Post-Abortion Care (SAFPAC) initiative, led by CARE, has provided contraceptives, including long-acting reversible contraceptives (LARCs), to refugees, internally displaced persons, and conflict-affected resident populations in Chad, the Democratic Republic of the Congo (DRC), Djibouti, Mali, and Pakistan. The project works through the Ministry of Health in 4 key areas: (1) competency-based training, (2) supply chain management, (3) systematic supervision, and (4) community mobilization to raise awareness and shift norms related to family planning. This article presents data on program results from July 2011 to December 2013 from the 5 countries. Project staff summarized monthly data from client registers using hard-copy forms and recorded the data electronically in Microsoft Excel for compilation and analysis. The initiative reached 52,616 new users of modern contraceptive methods across the 5 countries, ranging from 575 in Djibouti to 21,191 in Chad. LARCs have predominated overall, representing 61% of new modern method users. The percentage of new users choosing LARCs varied by country: 78% in the DRC, 72% in Chad, and 51% in Mali, but only 29% in Pakistan. In Djibouti, those methods were not offered in the country through SAFPAC during the period discussed here. In Chad, the DRC, and Mali, implants have been the most popular LARC method, while in Pakistan the IUD has been more popular. Use of IUDs, however, has comprised a larger share of the method mix over time in all 4 of these countries. These results to date suggest that it is feasible to work with the public sector in fragile, crisis-affected states to deliver a wide range of quality

  1. Control over photo-inscription and thermal annealing to obtain high-quality Bragg gratings in doped PMMA optical fibers.

    PubMed

    Hu, Xuehao; Kinet, Damien; Mégret, Patrice; Caucheteur, Christophe

    2016-07-01

    Bragg gratings are photo-inscribed in trans-4-stilbenemethanol doped PMMA fibers using a 325 nm He-Cd laser and a phase mask. Two distinct behaviors are reported depending on the laser power density. In the high-density regime with 637  mW/mm2, the grating reflectivity is stable over time after the writing process, but the reflected spectrum is of limited quality, as the grating length is limited to the laser width (1.2 mm). The beam is then enlarged to 6 mm, decreasing the power density to 127  mW/mm2. In this case, the grating reflectivity strongly decays after the writing process. A fortunate property here results from the recovery of the initial reflectivity using a post-inscription thermal annealing. Both behaviors are attributed to the evolution between trans- and cis-isomers.

  2. Quality of Best Possible Medication History upon Admission to Hospital: Comparison of Nurses and Pharmacy Students and Consideration of National Quality Indicators.

    PubMed

    Sproul, Ashley; Goodine, Carole; Moore, David; McLeod, Amy; Gordon, Jacqueline; Digby, Jennifer; Stoica, George

    2018-01-01

    Medication reconciliation at transitions of care increases patient safety. Collection of an accurate best possible medication history (BPMH) on admission is a key step. National quality indicators are used as surrogate markers for BPMH quality, but no literature on their accuracy exists. Obtaining a high-quality BPMH is often labour- and resource-intensive. Pharmacy students are now being assigned to obtain BPMHs, as a cost-effective means to increase BPMH completion, despite limited information to support the quality of BPMHs obtained by students relative to other health care professionals. To determine whether the national quality indicator of using more than one source to complete a BPMH is a true marker of quality and to assess whether BPMHs obtained by pharmacy students were of quality equal to those obtained by nurses. This prospective trial compared BPMHs for the same group of patients collected by nurses and by trained pharmacy students in the emergency departments of 2 sites within a large health network over a 2-month period (July and August 2016). Discrepancies between the 2 versions were identified by a pharmacist, who determined which party (nurse, pharmacy student, or both) had made an error. A panel of experts reviewed the errors and ranked their severity. BPMHs were prepared for a total of 40 patients. Those prepared by nurses were more likely to contain an error than those prepared by pharmacy students (171 versus 43 errors, p = 0.006). There was a nonsignificant trend toward less severe errors in BPMHs completed by pharmacy students. There was no significant difference in the mean number of errors in relation to the specified quality indicator (mean of 2.7 errors for BPMHs prepared from 1 source versus 4.8 errors for BPMHs prepared from ≥ 2 sources, p = 0.08). The surrogate marker (number of BPMH sources) may not reflect BPMH quality. However, it appears that BPMHs prepared by pharmacy students had fewer errors and were of similar quality (in

  3. High quality self-separated GaN crystal grown on a novel nanoporous template by HVPE.

    PubMed

    Huo, Qin; Shao, Yongliang; Wu, Yongzhong; Zhang, Baoguo; Hu, Haixiao; Hao, Xiaopeng

    2018-02-16

    In this study, a novel nanoporous template was obtained by a two-step etching process from MOCVD-GaN/Al 2 O 3 (MGA) with electrochemical etching sequentially followed by chemical wet etching. The twice-etched MOCVD-GaN/Al 2 O 3 (TEMGA) templates were utilized to grow GaN crystals by hydride vapor phase epitaxy (HVPE) method. The GaN crystals were separated spontaneously from the TEMGA template with the assistance of voids formed by the etched nanopores. Several techniques were utilized to characterize the quality of the free-standing GaN crystals obtained from the TEMGA template. Results showed that the quality of the as-obtained GaN crystals was improved obviously compared with those grown on the MGA. This convenient technique can be applied to grow high-quality free-standing GaN crystals.

  4. Data Assimilation Experiments using Quality Controlled AIRS Version 5 Temperature Soundings

    NASA Technical Reports Server (NTRS)

    SUsskind, Joel

    2008-01-01

    The AIRS Science Team Version 5 retrieval algorithm has been finalized and is now operational at the Goddard DAAC in the processing (and reprocessing) of all AIRS data. The AIRS Science Team Version 5 retrieval algorithm contains two significant improvements over Version 4: 1) Improved physics allows for use of AIRS observations in the entire 4.3 pm C02 absorption band in the retrieval of temperature profile T(p) during both day and night. Tropospheric sounding 15 pm C02 observations are now used primarily in the generation of cloud cleared radiances Ri. This approach allows for the generation of accurate values of Ri and T(p) under most cloud conditions. 2) Another very significant improvement in Version 5 is the ability to generate accurate case-by-case, level-by-level error estimates for the atmospheric temperature profile, as well as for channel-by- channel error estimates for Ri. These error estimates are used for quality control of the retrieved products. We have conducted forecast impact experiments assimilating AIRS temperature profiles with different levels of quality control using the NASA GEOS-5 data assimilation system. Assimilation of quality controlled T(p) resulted in significantly improved forecast skill compared to that obtained from analyses obtained when all data used operationally by NCEP, except for AIRS data, is assimilated. We also conducted an experiment assimilating AIRS radiances uncontaminated by clouds, as done Operationally by ECMWF and NCEP. Forecasts resulting from assimilated AIRS radiances were of poorer quality than those obtained assimilating AIRS temperatures.

  5. Obtaining antibiotics online from within the UK: a cross-sectional study

    PubMed Central

    Boyd, Sara Elizabeth; Moore, Luke Stephen Prockter; Gilchrist, Mark; Costelloe, Ceire; Castro-Sánchez, Enrique; Franklin, Bryony Dean; Holmes, Alison Helen

    2017-01-01

    Background: Improved antibiotic stewardship (AS) and reduced prescribing in primary care, with a parallel increase in personal internet use, could lead citizens to obtain antibiotics from alternative sources online. Objectives: A cross-sectional analysis was performed to: (i) determine the quality and legality of online pharmacies selling antibiotics to the UK public; (ii) describe processes for obtaining antibiotics online from within the UK; and (iii) identify resulting AS and patient safety issues. Methods: Searches were conducted for ‘buy antibiotics online’ using Google and Yahoo. For each search engine, data from the first 10 web sites with unique URL addresses were reviewed. Analysis was conducted on evidence of appropriate pharmacy registration, prescription requirement, whether antibiotic choice was ‘prescriber-driven’ or ‘consumer-driven’, and whether specific information was required (allergies, comorbidities, pregnancy) or given (adverse effects) prior to purchase. Results: Twenty unique URL addresses were analysed in detail. Online pharmacies evidencing their location in the UK (n = 5; 25%) required a prescription before antibiotic purchase, and were appropriately registered. Online pharmacies unclear about the location they were operating from (n = 10; 50%) had variable prescription requirements, and no evidence of appropriate registration. Nine (45%) online pharmacies did not require a prescription prior to purchase. For 16 (80%) online pharmacies, decisions were initially consumer-driven for antibiotic choice, dose and quantity. Conclusions: Wide variation exists among online pharmacies in relation to antibiotic practices, highlighting considerable patient safety and AS issues. Improved education, legislation, regulation and new best practice stewardship guidelines are urgently needed for online antibiotic suppliers. PMID:28333179

  6. Improving Library Service Quality to Graduate Students: LibQual+[TM] Survey Results in a Practical Setting

    ERIC Educational Resources Information Center

    Jankowska, Maria Anna; Hertel, Karen; Young, Nancy J.

    2006-01-01

    The LibQUAL+[TM] survey was conducted to determine user satisfaction and expectations concerning library service quality. The results of the "22 items and a box" constituted a rich source of information for the University of Idaho (UI) Library's strategic planning process. Focusing on graduate students, this study used three…

  7. Preliminary results of water quality assessment using phytoplankton and physicochemical approaches in the Huai River Basin, China.

    PubMed

    Chen, Hao; Zuo, Qi-Ting; Zhang, Yong-Yong

    2017-11-01

    Water pollution has been a significant issue in the Huai River Basin (HRB) of China since the late 1970s. In July and December 2013, two field investigations were carried out at 10 sites along the main streams of the basin. The monitoring indices contained both physicochemical variables and the structure and composition of phytoplankton communities. The correlations between communities and physicochemical variables were analyzed using cluster analysis and redundancy analysis. Moreover, water quality was evaluated using the comprehensive nutrition state index (TLI) and Shannon-Wiener diversity index (H). Results indicated that more phytoplankton species were present in December than in July, but total density was less in December. Phytoplankton communities in the midstream of the Shaying River were affected by the same physicochemical factors throughout the year, but ammonia nitrogen and total phosphorus had the greatest influence on these sites in July and December, respectively. The water pollution status of the sampling sites was much greater in the Shaying River midstream than at other sites. TLI was more suitable than H for assessing water quality in the study area. These results provide valuable information for policy makers and stakeholders in water quality assessment, water ecosystem restoration, and sustainable basin management in the HRB.

  8. Variable infiltration and river flooding resulting in changing groundwater quality - A case study from Central Europe

    NASA Astrophysics Data System (ADS)

    Miotliński, Konrad; Postma, Dieke; Kowalczyk, Andrzej

    2012-01-01

    SummaryThe changes in groundwater quality occurring in a buried valley aquifer following a reduction in groundwater exploitation and enhanced infiltration due to extensive flooding of the Odra River in 1997 were investigated. Long-time series data for the chemical composition of groundwater in a large well field for drinking water supply indicated the deterioration of groundwater quality in the wells capturing water from the flooded area, which had been intensively cultivated since the 1960s. Infiltration of flooded river water into the aquifer is suggested by an elevated chloride concentration, although salt flushing from the rewatered unsaturated zone due to the enhanced recharge event is much more feasible. Concomitantly with chloride increases in the concentrations of sulphate, ferrous iron, manganese, and nickel imply the oxidation of pyrite (FeS 2) which is abundant in the aquifer. The proton production resulting from pyrite oxidation is buffered by the dissolution of calcite, while the Ca:SO 4 stoichiometry of the groundwater indicates that pyrite oxidation coupled with nitrate reduction is the dominant process occurring in the aquifer. The pyritic origin of SO42- is confirmed by the sulphur isotopic composition. The resultant Fe 2+ increase induces Mn-oxide dissolution and the mobilisation of Ni 2+ previously adsorbed to Mn-oxide surfaces. The study has a major implication for groundwater quality prediction studies where there are considerable variations in water level associated with groundwater management and climate change issues.

  9. Quality Aware Compression of Electrocardiogram Using Principal Component Analysis.

    PubMed

    Gupta, Rajarshi

    2016-05-01

    Electrocardiogram (ECG) compression finds wide application in various patient monitoring purposes. Quality control in ECG compression ensures reconstruction quality and its clinical acceptance for diagnostic decision making. In this paper, a quality aware compression method of single lead ECG is described using principal component analysis (PCA). After pre-processing, beat extraction and PCA decomposition, two independent quality criteria, namely, bit rate control (BRC) or error control (EC) criteria were set to select optimal principal components, eigenvectors and their quantization level to achieve desired bit rate or error measure. The selected principal components and eigenvectors were finally compressed using a modified delta and Huffman encoder. The algorithms were validated with 32 sets of MIT Arrhythmia data and 60 normal and 30 sets of diagnostic ECG data from PTB Diagnostic ECG data ptbdb, all at 1 kHz sampling. For BRC with a CR threshold of 40, an average Compression Ratio (CR), percentage root mean squared difference normalized (PRDN) and maximum absolute error (MAE) of 50.74, 16.22 and 0.243 mV respectively were obtained. For EC with an upper limit of 5 % PRDN and 0.1 mV MAE, the average CR, PRDN and MAE of 9.48, 4.13 and 0.049 mV respectively were obtained. For mitdb data 117, the reconstruction quality could be preserved up to CR of 68.96 by extending the BRC threshold. The proposed method yields better results than recently published works on quality controlled ECG compression.

  10. Quality of anaesthesia-related information accessed via Internet searches.

    PubMed

    Caron, S; Berton, J; Beydon, L

    2007-08-01

    We conducted a study to examine the quality and stability of information available from the Internet on four anaesthesia-related topics. In January 2006, we searched using four key words (porphyria, scleroderma, transfusion risk, and epidural analgesia risk) with five search engines (Google, HotBot, AltaVista, Excite, and Yahoo). We used a published scoring system (NetScoring) to evaluate the first 15 sites identified by each of these 20 searches. We also used a simple four-point scale to assess the first 100 sites in the Google search on one of our four topics ('epidural analgesia risk'). In November 2006, we conducted a second evaluation, using three search engines (Google, AltaVista, and Yahoo) with 14 synonyms for 'epidural analgesia risk'. The five search engines performed similarly. NetScoring scores were lower for transfusion risk (P < 0.001). One or more high-quality sites was identified consistently among the first 15 sites in each search. Quality scored using the simple scale correlated closely with medical content and design by NetScoring and with the number of references (P < 0.05). Synonyms of 'epidural analgesia risk' yielded similar results. The quality of accessed information improved somewhat over the 11 month period with Yahoo and AltaVista, but declined with Google. The Internet is a valuable tool for obtaining medical information, but the quality of websites varies between different topics. A simple rating scale may facilitate the quality scoring on individual websites. Differences in precise search terms used for a given topic did not appear to affect the quality of the information obtained.

  11. Microstructure Investigation of 13Cr-2Mo ODS Steel Components Obtained by High Voltage Electric Discharge Compaction Technique.

    PubMed

    Bogachev, Igor; Yudin, Artem; Grigoryev, Evgeniy; Chernov, Ivan; Staltsov, Maxim; Khasanov, Oleg; Olevsky, Eugene

    2015-11-02

    Refractory oxide dispersion strengthened 13Cr-2Mo steel powder was successfully consolidated to near theoretical density using high voltage electric discharge compaction. Cylindrical samples with relative density from 90% to 97% and dimensions of 10 mm in diameter and 10-15 mm in height were obtained. Consolidation conditions such as pressure and voltage were varied in some ranges to determine the optimal compaction regime. Three different concentrations of yttria were used to identify its effect on the properties of the samples. It is shown that the utilized ultra-rapid consolidation process in combination with high transmitted energy allows obtaining high density compacts, retaining the initial structure with minimal grain growth. The experimental results indicate some heterogeneity of the structure which may occur in the external layers of the tested samples due to various thermal and electromagnetic in-processing effects. The choice of the optimal parameters of the consolidation enables obtaining samples of acceptable quality.

  12. Quality control of test iodine in urine by spectrophotometry UV-Vis

    NASA Astrophysics Data System (ADS)

    Huda, Thorikul; Nafisah, Durotun; Kumorowulan, Suryati; Lestari, Sri

    2017-12-01

    A quality control of iodine test in with UV-Vis spectrophotometry has been done. The purpose of this research is to find out whether the test results of samples conducted by Clinical Office of Research and Development Of GAKI (BP2GAKI) laboratory are still controlled, feasible and reliable, and still consistent over time, as indicated by the control chart. Quality control parameters are linearity, precision, accuracy, limit of detection, and limit of quantification. Based on the quality control that has been done, obtained linearity (r)= -0.9974, the detection limit and the limit of quantitation are respectively 2.26 µg/L and 7.54 µg/L, while the accuracy is calculated by %recovery and precision with value % RSD are 97.4161% and 1.7136% respectively. The quality control of iodine test in urine using the control chart shows excellent or stable results for 30 days and no variation of the results is very different for each day.

  13. Water quality assessment of Australian ports using water quality evaluation indices

    PubMed Central

    Jahan, Sayka

    2017-01-01

    Australian ports serve diverse and extensive activities, such as shipping, tourism and fisheries, which may all impact the quality of port water. In this work water quality monitoring at different ports using a range of water quality evaluation indices was applied to assess the port water quality. Seawater samples at 30 stations in the year 2016–2017 from six ports in NSW, Australia, namely Port Jackson, Botany, Kembla, Newcastle, Yamba and Eden, were investigated to determine the physicochemical and biological variables that affect the port water quality. The large datasets obtained were designed to determine the Water Quality Index, Heavy metal Evaluation Index, Contamination Index and newly developed Environmental Water Quality Index. The study revealed medium water quality index and high and medium heavy metal evaluation index at three of the study ports and high contamination index in almost all study ports. Low level dissolved oxygen and higher level of total dissolved solids, turbidity, fecal coliforms, copper, iron, lead, zinc, manganese, cadmium and cobalt are mainly responsible for the poor water qualities of the port areas. Good water quality at the background samples indicated that various port activities are the likely cause for poor water quality inside the port area. PMID:29244876

  14. Assessment of irrigation water quality. A proposal of a quality profile.

    PubMed

    Almeida, César; Quintar, Silvya; González, Patricia; Mallea, Miguel

    2008-07-01

    Water quality indices provide a simple and understandable tool for managers on the quality and possible uses for irrigation water, however an individual quality factor alone is not enough to evaluate the irrigation water quality because it could be restrictive and sometime it could give an unfavorable qualification. The aim of this paper was propose a quality profile of irrigation water using the preexisting water quality indices to be applied to arid and semi-arid regions. As a case studied, the water of the Del Molle River (Nogolí, San Luis, Argentina) was researched. Samples were collected during the period October 2005-May 2006. Conductivity, pH, total hardness, sulphate, nitrate, nitrite, alkalinity, chloride, sodium, potassium, TDS, DO and phosphate were analyzed. The irrigation water quality, according to Riverside Norm, belongs to C(2)-S(1) class, according to Wilcox Norm as excellent to good, according to Scott quality factor it is good and according to SAR < 10 and according to RCS it is recommendable. From the obtained data, it can be concluded that the water quality profile was good, so it is useful for normal irrigation agriculture.

  15. The Effect of Background Traffic Packet Size to VoIP Speech Quality

    NASA Astrophysics Data System (ADS)

    Triyason, Tuul; Kanthamanon, Prasert; Warasup, Kittipong; Yamsaengsung, Siam; Supattatham, Montri

    VoIP is gaining acceptance into the corporate world especially, in small and medium sized business that want to save cost for gaining advantage over their competitors. The good voice quality is one of challenging task in deployment plan because VoIP voice quality was affected by packet loss and jitter delay. In this paper, we study the effect of background traffic packet size to voice quality. The background traffic was generated by Bricks software and the speech quality was assessed by MOS. The obtained result shows an interesting relationship between the voice quality and the number of TCP packets and their size. With the same amount of data smaller packets affect the voice's quality more than the larger packet.

  16. The robust design for improving crude palm oil quality in Indonesian Mill

    NASA Astrophysics Data System (ADS)

    Maretia Benu, Siti; Sinulingga, Sukaria; Matondang, Nazaruddin; Budiman, Irwan

    2018-04-01

    This research was conducted in palm oil mill in Sumatra Utara Province, Indonesia. Currently, the main product of this mill is Crude Palm Oil (CPO) and hasn’t met the expected standard quality. CPO is the raw material for many fat derivative products. The generally stipulated quality criteria are dirt count, free fatty acid, and moisture of CPO. The aim of this study is to obtain the optimal setting for factor’s affect the quality of CPO. The optimal setting will result in an improvement of product’s quality. In this research, Experimental Design with Taguchi Method is used. Steps of this method are identified influence factors, select the orthogonal array, processed data using ANOVA test and signal to noise ratio, and confirmed the research using Quality Loss Function. The result of this study using Taguchi Method is to suggest to set fruit maturity at 75.4-86.9%, digester temperature at 95°C and press at 21 Ampere to reduce quality deviation until 42.42%.

  17. Evaluating supplier quality performance using analytical hierarchy process

    NASA Astrophysics Data System (ADS)

    Kalimuthu Rajoo, Shanmugam Sundram; Kasim, Maznah Mat; Ahmad, Nazihah

    2013-09-01

    This paper elaborates the importance of evaluating supplier quality performance to an organization. Supplier quality performance evaluation reflects the actual performance of the supplier exhibited at customer's end. It is critical in enabling the organization to determine the area of improvement and thereafter works with supplier to close the gaps. Success of the customer partly depends on supplier's quality performance. Key criteria as quality, cost, delivery, technology support and customer service are categorized as main factors in contributing to supplier's quality performance. 18 suppliers' who were manufacturing automotive application parts evaluated in year 2010 using weight point system. There were few suppliers with common rating which led to common ranking observed by few suppliers'. Analytical Hierarchy Process (AHP), a user friendly decision making tool for complex and multi criteria problems was used to evaluate the supplier's quality performance challenging the weight point system that was used for 18 suppliers'. The consistency ratio was checked for criteria and sub-criteria. Final results of AHP obtained with no overlap ratings, therefore yielded a better decision making methodology as compared to weight point rating system.

  18. Quality analysis of patient information about knee arthroscopy on the World Wide Web.

    PubMed

    Sambandam, Senthil Nathan; Ramasamy, Vijayaraj; Priyanka, Priyanka; Ilango, Balakrishnan

    2007-05-01

    This study was designed to ascertain the quality of patient information available on the World Wide Web on the topic of knee arthroscopy. For the purpose of quality analysis, we used a pool of 232 search results obtained from 7 different search engines. We used a modified assessment questionnaire to assess the quality of these Web sites. This questionnaire was developed based on similar studies evaluating Web site quality and includes items on illustrations, accessibility, availability, accountability, and content of the Web site. We also compared results obtained with different search engines and tried to establish the best possible search strategy to attain the most relevant, authentic, and adequate information with minimum time consumption. For this purpose, we first compared 100 search results from the single most commonly used search engine (AltaVista) with the pooled sample containing 20 search results from each of the 7 different search engines. The search engines used were metasearch (Copernic and Mamma), general search (Google, AltaVista, and Yahoo), and health topic-related search engines (MedHunt and Healthfinder). The phrase "knee arthroscopy" was used as the search terminology. Excluding the repetitions, there were 117 Web sites available for quality analysis. These sites were analyzed for accessibility, relevance, authenticity, adequacy, and accountability by use of a specially designed questionnaire. Our analysis showed that most of the sites providing patient information on knee arthroscopy contained outdated information, were inadequate, and were not accountable. Only 16 sites were found to be providing reasonably good patient information and hence can be recommended to patients. Understandably, most of these sites were from nonprofit organizations and educational institutions. Furthermore, our study revealed that using multiple search engines increases patients' chances of obtaining more relevant information rather than using a single search

  19. External quality assessment for CD4 + T-lymphocyte count test

    PubMed Central

    Gaspar, Pâmela Cristina; Wohlke, Bruna Lovizutto Protti; Brunialti, Milena Karina Coló; Pires, Ana Flávia; Kohiyama, Igor Massaki; Salomão, Reinaldo; Alonso Neto, José Boullosa; Júnior, Orlando da Costa Ferreira; Franchini, Miriam; Bazzo, Maria Luiza; Benzaken, Adele Schwartz

    2018-01-01

    Abstract The National Network for CD4+ T-lymphocyte counting of Brazil comprises 93 laboratories. This study reports the laboratory performances achieved in external quality assessment (EQA) rounds provides by Ministry of Health to evaluate the quality of the kits used and the performance of test by the technicians. Ten EQA rounds were analyzed according the EQA criteria aimed to evaluate individual laboratory performance on the basis of the accuracy of their results compared to the general mean obtained by all participating laboratories and the reproducibility of the results obtained between 2 samples from the same donor. The percentage of approved and failed laboratories in the EQAs tends to follow a uniform pattern. Since 2011, approval has remained above 80% and the failure rate has never exceeded 15%. EQA is very important to evaluate the performance of the laboratories, to identify monitor, and to resolve errors as quickly as possible. PMID:29794603

  20. Ground-Water Quality Data in the Central Eastside San Joaquin Basin 2006: Results from the California GAMA Program

    USGS Publications Warehouse

    Landon, Matthew K.; Belitz, Kenneth

    2008-01-01

    for approximately one-sixth of the wells, and the results for these samples were used to evaluate the quality of the data for the ground-water samples. Assessment of the quality-control results showed that the environmental data were of good quality, with low bias and low variability, and resulted in censoring of less than 0.3 percent of the detections found in ground-water samples. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, and (or) blended with other waters to maintain acceptable water quality. Regulatory thresholds apply to treated water that is served to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CADPH) and thresholds established for aesthetic concerns (secondary maximum contaminant levels, SMCL-CA) by CADPH. VOCs and pesticides were detected in approximately half of the grid wells, and all detections in samples from CESJO wells were below health-based thresholds. All detections of nutrients and major elements in grid wells also were below health-based thresholds. Most detections of constituents of special interest, trace elements, and radioactive constituents in samples from grid wells were below health-based thresholds. Exceptions included two detections of arsenic that were above the USEPA maximum contaminant level (MCL-US), one detection of lead above the USEPA action level (AL-US), and one detection of vanadium and three detections of 1,2,3-TCP that were above the CADPH notification levels (NL-CA). All detections of radioactive constituents were below health-based thresholds, although fourteen samples had activities of radon-222 above the lower proposed MCL-US. Most of th

  1. Influence of grid control and object detection on radiation exposure and image quality using mobile C-arms - first results.

    PubMed

    Gosch, D; Ratzmer, A; Berauer, P; Kahn, T

    2007-09-01

    The objective of this study was to examine the extent to which the image quality on mobile C-arms can be improved by an innovative exposure rate control system (grid control). In addition, the possible dose reduction in the pulsed fluoroscopy mode using 25 pulses/sec produced by automatic adjustment of the pulse rate through motion detection was to be determined. As opposed to conventional exposure rate control systems, which use a measuring circle in the center of the field of view, grid control is based on a fine mesh of square cells which are overlaid on the entire fluoroscopic image. The system uses only those cells for exposure control that are covered by the object to be visualized. This is intended to ensure optimally exposed images, regardless of the size, shape and position of the object to be visualized. The system also automatically detects any motion of the object. If a pulse rate of 25 pulses/sec is selected and no changes in the image are observed, the pulse rate used for pulsed fluoroscopy is gradually reduced. This may decrease the radiation exposure. The influence of grid control on image quality was examined using an anthropomorphic phantom. The dose reduction achieved with the help of object detection was determined by evaluating the examination data of 146 patients from 5 different countries. The image of the static phantom made with grid control was always optimally exposed, regardless of the position of the object to be visualized. The average dose reduction when using 25 pulses/sec resulting from object detection and automatic down-pulsing was 21 %, and the maximum dose reduction was 60 %. Grid control facilitates C-arm operation, since optimum image exposure can be obtained independently of object positioning. Object detection may lead to a reduction in radiation exposure for the patient and operating staff.

  2. In vitro comparison between the image obtained using PSP plates and Kodak E-speed films.

    PubMed

    Petel, R; Yaroslavsky, L; Kaffe, I

    2014-07-01

    The aim of this study was to compare the intra-oral radiographic images obtained by a PSP digital radiography system ("Orex", Israel) with that obtained using Kodak Ultra speed films in terms of image quality, radiation dosage and diagnostic value. The physical measurement of image quality was conducted with an aluminum step-wedge. Radiation dosage was measured with a dosimeter. Fog and base levels were measured by developing unexposed films and scanning unexposed PSP plates. The in vitro model included preparation and radiographic evaluation of approximal artificial lesions in premolars and molars in depths ranging from 0.25 mm to 1.00 mm. Radiographs were evaluated for the existence of a lesion and its size by 8 experienced clinicians. Relative contrast was similar in both methods. The resolving power of the digital system was lower than that of the E-speed film. As for the subjective evaluation of artificial lesions, there was no significant difference between the two methods excluding those tooth images without lesions, where the analog method was found to be more accurate. The PSP system ("Orex") provides good image quality and diagnostic information with reduced exposure when compared with E-speed film.

  3. The impact of iron overload and its treatment on quality of life: results from a literature review

    PubMed Central

    Abetz, Linda; Baladi, Jean-Francois; Jones, Paula; Rofail, Diana

    2006-01-01

    Background To assess the literature for the impact of iron overload and infusion Iron Chelation Therapy (ICT) on patients' quality of life (QoL), and the availability of QoL instruments for patients undergoing infusion ICT. Also, to obtain patients' experiences of having iron overload and receiving infusion ICT, and experts' clinical opinions about the impact of treatment on patients' lives. Methods A search of studies published between 1966 and 2004 was conducted using Medline and the Health Economic Evaluation Database (HEED). Qualitative results from patient and expert interviews were analysed. Hand searching of relevant conference abstracts completed the search. Results Few studies measuring the impact of ICT with deferoxamine (DFO) on patients QoL were located (n = 15). QoL domains affected included: depression; fatigue; dyspnoea; physical functioning; psychological distress; decrease in QoL during hospitalization. One theme in all articles was that oral ICT should improve QoL. No iron overload or ICT-specific QoL instruments were located in the articles. Interviews revealed that the impact of ICT on patients with thalassemia, sickle cell disease, and myelodysplastic syndromes is high. Conclusion A limited number of studies assessed the impact of ICT or iron overload on QoL. All literature suggested a need for easily administered, efficacious and well tolerated oral iron overload treatments, given the impact of current ICT on adherence. Poor adherence to ICT was documented to negatively impact survival. Further research is warranted to continue the qualitative and quantitative study of QoL using validated instruments in patients receiving ICT to further understanding the issues and improve patients QoL. PMID:17007645

  4. Case studies evaluating the quality of synthetic environments

    NASA Astrophysics Data System (ADS)

    Deisinger, Joachim; Blach, Roland; Simon, Andreas

    1999-03-01

    Multi wall stereo projection systems (MWSP) are an emerging display paradigm, promising a new quality in 3D-real-time interactions. Not much is known about the ergonomics of these systems. In this paper some basics of perception and approaches to improve the visual quality will be discussed and results of four experiments will be presented in order to obtain a better understanding of user interactions with existing projection technology. Due to the limited number of participants the experiments are considered as case-studies only. The first task was the estimation of absolute geometrical dimensions of simple objects. The second task was grabbing simple objects of different sizes. In order to classify MWSP, these tasks were compared to other display devices and compared to physical reality. We conducted two further experiments to compare different viewing devices for virtual reality (VR) like Head Mounted Displays (HMD), monitor, and the MWSP. For all of those experiments quantitative data was collected as a measure of interaction quality. The last two tests were supported by pre- and post questionnaires to obtain subjective judgement of the displays as well.

  5. Obtaining of granular fertilizers based on ashes from combustion of waste residues and ground bones using phosphorous solubilization by bacteria Bacillus megaterium.

    PubMed

    Rolewicz, M; Rusek, P; Borowik, K

    2018-06-15

    The article presents research results on obtaining phosphorus granulated fertilizers on the basis of microbiologically activated sewage sludge ashes, ground bones and dried blood from meat industry. Granulation tests were carried out using a laboratory pan granulator as well as on an experimental pilot plant. The aim of the studies was to select the proper composition of the mixture of raw materials and binding agents to obtain granulated fertilizers from waste materials such as MSSA and MBM and bacteria lyophilisate. Obtained fertilizer samples were subjected to physical tests (granulation tests etc.) and quality assessment. The tests confirmed that it was possible to produce granulated phosphate fertilizers using the Bacillus megaterium for solubilization of phosphorus in a simple process. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Dynamic 99mTc-MAG3 renography: images for quality control obtained by combining pharmacokinetic modelling, an anthropomorphic computer phantom and Monte Carlo simulated scintillation camera imaging

    NASA Astrophysics Data System (ADS)

    Brolin, Gustav; Sjögreen Gleisner, Katarina; Ljungberg, Michael

    2013-05-01

    In dynamic renal scintigraphy, the main interest is the radiopharmaceutical redistribution as a function of time. Quality control (QC) of renal procedures often relies on phantom experiments to compare image-based results with the measurement setup. A phantom with a realistic anatomy and time-varying activity distribution is therefore desirable. This work describes a pharmacokinetic (PK) compartment model for 99mTc-MAG3, used for defining a dynamic whole-body activity distribution within a digital phantom (XCAT) for accurate Monte Carlo (MC)-based images for QC. Each phantom structure is assigned a time-activity curve provided by the PK model, employing parameter values consistent with MAG3 pharmacokinetics. This approach ensures that the total amount of tracer in the phantom is preserved between time points, and it allows for modifications of the pharmacokinetics in a controlled fashion. By adjusting parameter values in the PK model, different clinically realistic scenarios can be mimicked, regarding, e.g., the relative renal uptake and renal transit time. Using the MC code SIMIND, a complete set of renography images including effects of photon attenuation, scattering, limited spatial resolution and noise, are simulated. The obtained image data can be used to evaluate quantitative techniques and computer software in clinical renography.

  7. [Quality management in acute pain therapy: results from a survey of certified hospitals].

    PubMed

    Böhmer, A B; Poels, M; Simanski, C; Trojan, S; Messer, K; Wirtz, M D; Neugebauer, E A M; Wappler, F; Joppich, R

    2012-08-01

    Systems for and methods of quality management are increasingly being implemented in public health services. The aim of our study was to analyze the current state of the integrated quality management concept "quality management acute pain therapy" of the TÜV Rheinland® (TÜV) after a 5-year project period. General characteristics of the participating hospitals, number of departments certified by the TÜV and implementation of structures and processes according to the TÜV guidelines were evaluated by a mail questionnaire. Furthermore, positive and negative aspects concerning the effects of certification were evaluated by the hospitals' representatives of certification. A total of 36 questionnaires were returned. Since 2006 the number of certified hospitals (2011: n = 48) and surgical departments (2011: n = 202) has increased continuously. The number of certified medical departments is low (2011: n = 39); however, in the last 3 years, it has increased by about 200-300% annually. Standard operative procedures for pain therapy and measurement of pain intensity at regular intervals were implemented in all certified clinics (100%). Although 41% take part in the benchmarking project QUIPS (Quality Improvement in Postoperative Pain Therapy), 24% do not systematically check the quality of the outcome of pain management. Acceptance of the new pain therapy concepts among nursing staff was rated positively (ratio positive:negative 16:1); however, acceptance among physicians was rated negatively (1:15). Certification by the TÜV leads to sustainable implementation of quality management principles. Future efforts should focus on better integration of physicians in acute pain therapy and the development of an integrated tool to measure patients' outcome.

  8. Application of QC_DR software for acceptance testing and routine quality control of direct digital radiography systems: initial experiences using the Italian Association of Physicist in Medicine quality control protocol.

    PubMed

    Nitrosi, Andrea; Bertolini, Marco; Borasi, Giovanni; Botti, Andrea; Barani, Adriana; Rivetti, Stefano; Pierotti, Luisa

    2009-12-01

    Ideally, medical x-ray imaging systems should be designed to deliver maximum image quality at an acceptable radiation risk to the patient. Quality assurance procedures are employed to ensure that these standards are maintained. A quality control protocol for direct digital radiography (DDR) systems is described and discussed. Software to automatically process and analyze the required images was developed. In this paper, the initial results obtained on equipment of different DDR manufacturers were reported. The protocol was developed to highlight even small discrepancies in standard operating performance.

  9. Harnessing electronic healthcare data for wound care research: Standards for reporting observational registry data obtained directly from electronic health records.

    PubMed

    Fife, Caroline E; Eckert, Kristen A

    2017-04-01

    The United States Food and Drug Administration will consider the expansion of coverage indications for some drugs and devices based on real-world data. Real-world data accrual in patient registries has historically been via manual data entry from the medical chart at a time distant from patient care, which is fraught with systematic error. The efficient automated transmission of data directly from electronic health records is replacing this labor-intensive paradigm. However, real-world data collection is unfamiliar. The potential sources of bias arising from the source of data and data accrual, documentation, and aggregation have not been well defined. Furthermore, the technological aspects of data acquisition and transmission are less transparent. We explore opportunities for harnessing direct-from-electronic health record registry reporting and propose the ABCs of Registries (Analysis of Bias Criteria of Registries), which are an evaluation framework for publications to minimize potential bias of real-world data obtained directly from an electronic health record method. These standards are based on a point-of-care data documentation process using a common definitional framework and data dictionaries. By way of example, we describe a wound registry obtained directly from electronic health records. This qualified clinical data registry minimizes bias by ensuring complete and accurate point-of-care data capture, standardizes usual care linked to quality reporting, and prevents post-hoc vetting of outcomes. The resulting data are of high quality and integrity and can be used for comparative effectiveness research in wound care. In this way, the effort needed to succeed with the Quality Payment Program is leveraged to obtain the real-world data needed for comparative effectiveness research. © 2017 by the Wound Healing Society.

  10. FQC Dashboard: integrates FastQC results into a web-based, interactive, and extensible FASTQ quality control tool.

    PubMed

    Brown, Joseph; Pirrung, Meg; McCue, Lee Ann

    2017-06-09

    FQC is software that facilitates quality control of FASTQ files by carrying out a QC protocol using FastQC, parsing results, and aggregating quality metrics into an interactive dashboard designed to richly summarize individual sequencing runs. The dashboard groups samples in dropdowns for navigation among the data sets, utilizes human-readable configuration files to manipulate the pages and tabs, and is extensible with CSV data. FQC is implemented in Python 3 and Javascript, and is maintained under an MIT license. Documentation and source code is available at: https://github.com/pnnl/fqc . joseph.brown@pnnl.gov. © The Author(s) 2017. Published by Oxford University Press.

  11. Evaluation of Shiraz wastewater treatment plant effluent quality for agricultural irrigation by Canadian Water Quality Index (CWQI)

    PubMed Central

    2013-01-01

    Background Using treated wastewater in agriculture irrigation could be a realistic solution for the shortage of fresh water in Iran, however, it is associated with environmental and health threats; therefore, effluent quality assessment is quite necessary before use. The present study aimed to evaluate the physicochemical and microbial quality of Shiraz wastewater treatment plant effluent for being used in agricultural irrigation. In this study, 20 physicochemical and 3 microbial parameters were measured during warm (April to September) and cold months (October to march). Using the measured parameters and the Canadian Water Quality Index, the quality of the effluent was determined in both warm and cold seasons and in all the seasons together. Results The calculated index for the physicochemical parameters in the effluent was equal (87) in warm and cold months and it was obtained as 85 for the seasons all together. When the microbial parameters were used in order to calculate the index, it declined to 67 in warm and cold seasons and 64 in all the seasons together. Also, it was found that three physicochemical parameters (TDS, EC, and NO3) and three microbial parameters (Fecal coliform, Helminthes egg, and Total coliform) had the most contribution to the reduction of the index value. Conclusions The results showed that the physicochemical quality of Shiraz Wastewater Treatment Plant Effluent was good for irrigation in the warm, cold, and total of the two kinds of seasons. However, by applying the microbial parameter, the index value declined dramatically and the quality of the effluent was marginal. PMID:23566673

  12. Projection pursuit water quality evaluation model based on chicken swam algorithm

    NASA Astrophysics Data System (ADS)

    Hu, Zhe

    2018-03-01

    In view of the uncertainty and ambiguity of each index in water quality evaluation, in order to solve the incompatibility of evaluation results of individual water quality indexes, a projection pursuit model based on chicken swam algorithm is proposed. The projection index function which can reflect the water quality condition is constructed, the chicken group algorithm (CSA) is introduced, the projection index function is optimized, the best projection direction of the projection index function is sought, and the best projection value is obtained to realize the water quality evaluation. The comparison between this method and other methods shows that it is reasonable and feasible to provide decision-making basis for water pollution control in the basin.

  13. The relationship of the local food environment with obesity: A systematic review of methods, study quality, and results.

    PubMed

    Cobb, Laura K; Appel, Lawrence J; Franco, Manuel; Jones-Smith, Jessica C; Nur, Alana; Anderson, Cheryl A M

    2015-07-01

    To examine the relationship between local food environments and obesity and assess the quality of studies reviewed. Systematic keyword searches identified studies from US and Canada that assessed the relationship of obesity to local food environments. We applied a quality metric based on design, exposure and outcome measurement, and analysis. We identified 71 studies representing 65 cohorts. Overall, study quality was low; 60 studies were cross-sectional. Associations between food outlet availability and obesity were predominantly null. Among non-null associations, we saw a trend toward inverse associations between supermarket availability and obesity (22 negative, 4 positive, 67 null) and direct associations between fast food and obesity (29 positive, 6 negative, 71 null) in adults. We saw direct associations between fast food availability and obesity in lower income children (12 positive, 7 null). Indices including multiple food outlets were most consistently associated with obesity in adults (18 expected, 1 not expected, 17 null). Limiting to higher quality studies did not affect results. Despite the large number of studies, we found limited evidence for associations between local food environments and obesity. The predominantly null associations should be interpreted cautiously due to the low quality of available studies. © 2015 The Obesity Society.

  14. A comprehensive method for GNSS data quality determination to improve ionospheric data analysis.

    PubMed

    Kim, Minchan; Seo, Jiwon; Lee, Jiyun

    2014-08-14

    Global Navigation Satellite Systems (GNSS) are now recognized as cost-effective tools for ionospheric studies by providing the global coverage through worldwide networks of GNSS stations. While GNSS networks continue to expand to improve the observability of the ionosphere, the amount of poor quality GNSS observation data is also increasing and the use of poor-quality GNSS data degrades the accuracy of ionospheric measurements. This paper develops a comprehensive method to determine the quality of GNSS observations for the purpose of ionospheric studies. The algorithms are designed especially to compute key GNSS data quality parameters which affect the quality of ionospheric product. The quality of data collected from the Continuously Operating Reference Stations (CORS) network in the conterminous United States (CONUS) is analyzed. The resulting quality varies widely, depending on each station and the data quality of individual stations persists for an extended time period. When compared to conventional methods, the quality parameters obtained from the proposed method have a stronger correlation with the quality of ionospheric data. The results suggest that a set of data quality parameters when used in combination can effectively select stations with high-quality GNSS data and improve the performance of ionospheric data analysis.

  15. Quality assessment of systematic reviews on alveolar socket preservation.

    PubMed

    Moraschini, V; Barboza, E Dos S P

    2016-09-01

    The aim of this overview was to evaluate and compare the quality of systematic reviews, with or without meta-analysis, that have evaluated studies on techniques or biomaterials used for the preservation of alveolar sockets post tooth extraction in humans. An electronic search was conducted without date restrictions using the Medline/PubMed, Cochrane Library, and Web of Science databases up to April 2015. Eligibility criteria included systematic reviews, with or without meta-analysis, focused on the preservation of post-extraction alveolar sockets in humans. Two independent authors assessed the quality of the included reviews using AMSTAR and the checklist proposed by Glenny et al. in 2003. After the selection process, 12 systematic reviews were included. None of these reviews obtained the maximum score using the quality assessment tools implemented, and the results of the analyses were highly variable. A significant statistical correlation was observed between the scores of the two checklists. A wide structural and methodological variability was observed between the systematic reviews published on the preservation of alveolar sockets post tooth extraction. None of the reviews evaluated obtained the maximum score using the two quality assessment tools implemented. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  16. Food away from home and body mass outcomes: taking heterogeneity into account enhances quality of results.

    PubMed

    Kim, Tae Hyun; Lee, Eui-Kyung; Han, Euna

    2014-09-01

    The aim of this study was to explore the heterogeneous association of consumption of food away from home (FAFH) with individual body mass outcomes including body mass index and waist circumference over the entire conditional distribution of each outcome. Information on 16,403 adults obtained from nationally representative data on nutrition and behavior in Korea was used. A quantile regression model captured the variability of the association of FAFH with body mass outcomes across the entire conditional distribution of each outcome measure. Heavy FAFH consumption was defined as obtaining ≥1400 kcal from FAFH on a single day. Heavy FAFH consumption, specifically at full-service restaurants, was significantly associated with higher body mass index (+0.46 kg/m2 at the 50th quantile, 0.55 at the 75th, 0.66 at the 90th, and 0.44 at the 95th) and waist circumference (+0.96 cm at the 25th quantile, 1.06 cm at the 50th, 1.35 cm at the 75th, and 0.96 cm at the 90th quantiles) with overall larger associations at higher quantiles. Findings of the study indicate that conventional regression methods may mask important heterogeneity in the association between heavy FAFH consumption and body mass outcomes. Further public health efforts are needed to improve the nutritional quality of affordable FAFH choices and nutrition education and to establish a healthy food consumption environment. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Nurses' Emotional Intelligence Impact on the Quality of Hospital Services

    PubMed Central

    Ranjbar Ezzatabadi, Mohammad; Bahrami, Mohammad Amin; Hadizadeh, Farzaneh; Arab, Masoomeh; Nasiri, Soheyla; Amiresmaili, Mohammadreza; Ahmadi Tehrani, Gholamreza

    2012-01-01

    Background Emotional intelligence is the potential to feel, use, communicate, recognize, remember, describe, identify, learn from, manage, understand and explain emotions. Service quality also can be defined as the post-consumption assessment of the services by consumers that are determined by many variables. Objectives This study was aimed to determine the nurses’ emotional intelligence impact on the delivered services quality. Materials and Methods This descriptive - applied study was carried out through a cross-sectional method in 2010. The research had 2 populations comprising of patients admitted to three academic hospitals of Yazd and the hospital nurses. Sample size was calculated by sample size formula for unlimited (patients) and limited (nursing staff) populations and obtained with stratified- random method. The data was collected by 4 valid questionnaires. Results The results of study indicated that nurses' emotional intelligence has a direct effect on the hospital services quality. The study also revealed that nurse's job satisfaction and communication skills have an intermediate role in the emotional intelligence and service quality relation. Conclusions This paper reports a new determinant of hospital services quality. PMID:23482866

  18. Improving quality of reproductive health care in Senegal through formative supervision: results from four districts.

    PubMed

    Suh, Siri; Moreira, Philippe; Ly, Moussa

    2007-11-29

    In Senegal, traditional supervision often focuses more on collection of service statistics than on evaluation of service quality. This approach yields limited information on quality of care and does little to improve providers' competence. In response to this challenge, Management Sciences for Health (MSH) has implemented a program of formative supervision. This multifaceted, problem-solving approach collects data on quality of care, improves technical competence, and engages the community in improving reproductive health care. This study evaluated changes in service quality and community involvement after two rounds of supervision in 45 health facilities in four districts of Senegal. We used checklists to assess quality in four areas of service delivery: infrastructure, staff and services management, record-keeping, and technical competence. We also measured community involvement in improving service quality using the completion rates of action plans. The most notable improvement across regions was in infection prevention.Management of staff, services, and logistics also consistently improved across the four districts. Record-keeping skills showed variable but lower improvement by region. The completion rates of action plans suggest that communities are engaged in improving service quality in all four districts. Formative supervision can improve the quality of reproductive health services, especially in areas where there is on-site skill building and refresher training. This approach can also mobilize communities to participate in improving service quality.

  19. Development and implementation of an audit tool for quality control of parenteral nutrition.

    PubMed

    García-Rodicio, Sonsoles; Abajo, Celia; Godoy, Mercedes; Catalá, Miguel Angel

    2009-01-01

    The aim of this article is to describe the development of a quality control methodology applied to patients receiving parenteral nutrition (PN) and to present the results obtained over the past 10 years. Development of the audit tool: In 1995, a total of 13 PN quality criteria and their standards were defined based on literature and past experiences. They were applied during 5 different 6-month audits carried out in subsequent years. According to the results of each audit, the criteria with lower validity were eliminated, while others were optimized and new criteria were introduced to complete the monitoring of other areas not previously examined. Currently, the quality control process includes 22 quality criteria and their standards that examine the following 4 different areas: (1) indication and duration of PN; (2) nutrition assessment, adequacy of the nutrition support, and monitoring; (3) metabolic and infectious complications; and (4) global efficacy of the nutrition support regimen. The authors describe the current definition of each criterion and present the results obtained in the 5 audits performed. In the past year, 9 of the 22 criteria reached the predefined standards. The areas detected for further improvements were: indication for PN, nutrition assessment, and management of catheter infections. The definition of quality criteria and their standards is an efficient method of providing a qualitative and quantitative analysis of the clinical care of patients receiving PN. It detects areas for improvement and assists in developing a methodology to work efficiently.

  20. The reporting quality of meta-analysis results of systematic review abstracts in periodontology and implant dentistry is suboptimal.

    PubMed

    Polychronopoulou, Argy

    2014-12-01

    Assessment of the quality of reporting in abstracts of systematic reviews with meta-analyses in periodontology and implant dentistry. Faggion CM Jr., Liu J, Huda F, Atieh M. J Periodontal Res 2014; 49(2):137-42. Argy Polychronopoulou, DDS, MS, ScM, ScD PURPOSE/QUESTION: What is the reporting quality of meta-analysis results of abstracts of systematic reviews in periodontology and implant dentistry journals? The authors received no funding for this study Meta-epidemiological study Level 3: Other evidence Not applicable. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Short periods of incubation, egg turning during storage and broiler breeder hens age for early development of embryos, hatching results, chicks quality and juvenile growth.

    PubMed

    Damaziak, K; Paweska, M; Gozdowski, D; Niemiec, J

    2018-05-14

    An effect of modification of storage conditions of the eggs of broiler breeder flocks at the age of 49-, 52- and 70-, 73-wks of life on an early embryonic development, hatching time and synchronization, hatchability rates, chicks quality and broiler growth was investigated. The eggs were divided into 4 experimental groups: COI = eggs storage 5 d, at turning every 12 h; NSP = eggs storage 12 d, at turning every 12 h; SPIDES = were treated with 4 h pre-incubation at 30°C and 50-55% air humidity, delivered at 5 and 10 d over of 12 d of storage, and turning every 12 h; NCOI = eggs storage 12 d, no turning and no pre-incubation. Eggs from older hens were characterized by poorer hatchability and poorer chicks quality. The use of 2 × 4 h pre-incubation in 12 d of eggs storage could have an effect on the initial acceleration of embryonic development in eggs of young hens, contributing to the alignment of embryos development in eggs from young and older hens to 72 h of incubation. Pre-incubation had no effect on the length of incubation period, hatching window, but it increased the hatchability of the set and apparently fertilized eggs and decreased the number of eggs not hatched, and also improved chicks quality. Eggs turning by 90° every 12 h during the storage positively affected the embryonic development, shortening the incubation time and the quality of chicks, but had no effect on hatchability rates and body weight in 42 d of life. Based on the obtained results, it can be concluded that the applied modifications can be effective in counteracting the negative effects of storage of hatching eggs from both young and older birds.

  2. Water-quality assessment of the Kentucky River basin, Kentucky; results of investigations of surface-water quality, 1987-90

    USGS Publications Warehouse

    Haag, K.H.; Garcia, Rene; Jarrett, G.L.; Porter, S.D.

    1995-01-01

    The U.S. Geological Survey investigated the water quality of the Kentucky River Basin in Kentucky as part of the National Water-Quality Assessment program. Data collected during 1987-90 were used to describe the spatial and temporal variability of water-quality constituents including metals and trace elements, nutrients, sediments, pesticides, dissolved oxygen, and fecal-coliform bacteria. Oil-production activities were the source of barium, bromide, chloride, magnesium, and sodium in several watersheds. High concentrations of aluminum, iron, and zinc were related to surface mining in the Eastern Coal Field Region. High concentrations of lead and zinc occurred in streambed sediments in urban areas, whereas concentrations of arsenic, strontium, and uranium were associated with natural geologic sources. Concentrations of phosphorus were significantly correlated with urban and agricultural land use. The high phosphorus content of Bluegrass Region soils was an important source of phosphorus in streams. At many sites in urban areas, most of the stream nitrogen load was attributable to wastewater-treatment-plant effluent. Average suspended-sediment concentrations were positively correlated with discharge. There was a downward trend in suspended-sediment concentrations downstream in the Kentucky River main stem during the study. The most frequently detected herbicides in water samples were atrazine, 2,4-D, alachlor, metolachlor, and dicamba. Diazinon, malathion, and parathion were the most frequently detected organophosphate insecticides in water samples. Detectable concentrations of aldrin, chlordane, DDT, DDE, dieldrin, endrin, endosulfan, heptachlor, and lindane were found in streambed-sediment samples. Dissolved-oxygen concentrations were sometimes below the minimum concentration needed to sustain aquatic life. At some sites, high concentrations of fecal-indicator bacteria were found and water samples did not meet sanitary water-quality criteria.

  3. Phosphate Reduction in Emulsified Meat Products: Impact of Phosphate Type and Dosage on Quality Characteristics.

    PubMed

    Glorieux, Seline; Goemaere, Olivier; Steen, Liselot; Fraeye, Ilse

    2017-09-01

    Phosphate reduction is of important industrial relevance in the manufacturing of emulsified meat products because it may give rise to a healthier product. The effect of seven different phosphate types was tested on the physicochemical and quality characteristics to select the most promising phosphate type for further cooked sausage manufacturing. Next, phosphate mass fraction was gradually reduced. Tetrasodium di- or pyrophosphate (TSPP) and sodium tripolyphosphate (STPP) increased pH, reduced structural properties, resulted in the highest emulsion stability, lowest cooking loss and had little effect on hardness. Based on the viscoelastic properties, a minimum mass fraction of 0.06% TSPP was sufficient to obtain an acceptable quality product. Rheology proved to be a very useful tool to evaluate the quality of meat products, as it gives insight in the structure of the meat product and especially the functional properties of meat proteins. Based on the obtained results, it can be concluded that the current amount of phosphate added to emulsified meat products can be significantly reduced with minimal loss of product quality.

  4. Phosphate Reduction in Emulsified Meat Products: Impact of Phosphate Type and Dosage on Quality Characteristics

    PubMed Central

    2017-01-01

    Summary Phosphate reduction is of important industrial relevance in the manufacturing of emulsified meat products because it may give rise to a healthier product. The effect of seven different phosphate types was tested on the physicochemical and quality characteristics to select the most promising phosphate type for further cooked sausage manufacturing. Next, phosphate mass fraction was gradually reduced. Tetrasodium di- or pyrophosphate (TSPP) and sodium tripolyphosphate (STPP) increased pH, reduced structural properties, resulted in the highest emulsion stability, lowest cooking loss and had little effect on hardness. Based on the viscoelastic properties, a minimum mass fraction of 0.06% TSPP was sufficient to obtain an acceptable quality product. Rheology proved to be a very useful tool to evaluate the quality of meat products, as it gives insight in the structure of the meat product and especially the functional properties of meat proteins. Based on the obtained results, it can be concluded that the current amount of phosphate added to emulsified meat products can be significantly reduced with minimal loss of product quality. PMID:29089852

  5. Preliminary Results from Duplex Procedure for Obtain of Fe Based Materials for Automotive Applications

    NASA Astrophysics Data System (ADS)

    Crăciun, R. C.; Stanciu, S.; Geantă, V.; Voiculescu, I.; Manole, V.; Gârneţ, I. A.; Alexandru, A.; Cimpoesu, N.; Săndulache, F.

    2017-06-01

    Abstract Iron based materials still represent a high percentage from metallic materials used in industry, in general, and in automotive industry, in particular. In this case we used a duplex process in order to obtain the FeMnSiAl experimental alloy for a more efficient use of various units. In the first stage iron, manganese, silicon and aluminum were melted and mixed together using arc melting technology and for the second stage the alloy was re-melt for homogeneity in an induction furnace. Chemical composition, after each melting step, was analyzed using EDS Bruker detector for various areas and microstructural characterization using SEM, VegaTescan LMH II with SE detector, equipment. This alloy is proposed as a metallic approach of mechanical dumpers used in automotive industry for low and medium impact contacts.

  6. Quality of Diabetes Care Predicts the Development of Cardiovascular Events: Results of the AMD-QUASAR Study

    PubMed Central

    Rossi, Maria C.E.; Lucisano, Giuseppe; Comaschi, Marco; Coscelli, Carlo; Cucinotta, Domenico; Di Blasi, Patrizia; Bader, Giovanni; Pellegrini, Fabio; Valentini, Umberto; Vespasiani, Giacomo; Nicolucci, Antonio

    2011-01-01

    OBJECTIVE The QUASAR (Quality Assessment Score and Cardiovascular Outcomes in Italian Diabetes Patients) study aimed to assess whether a quality-of-care summary score predicted the development of cardiovascular (CV) events in patients with type 2 diabetes. RESEARCH DESIGN AND METHODS In 67 diabetes clinics, data on randomly selected patients were extracted from electronic medical records. The score was calculated using process and outcome indicators based on monitoring, targets, and treatment of A1C, blood pressure, LDL cholesterol, and microalbuminuria. The score ranged from 0 to 40. RESULTS Overall, 5,181 patients were analyzed; 477 (9.2%) patients developed a CV event after a median follow-up of 28 months. The incidence rate (per 1,000 person-years) of CV events was 62.4 in patients with a score of <15, 41.0 in those with a score between 20 and 25 and 36.7 in those with a score of >25. Multilevel analysis, adjusted for clustering and case-mix, showed that the risk to develop a new CV event was 84% higher in patients with a score of <15 (incidence rate ratio [IRR] = 1.84; 95% confidence interval [CI] 1.29–2.62) and 17% higher in those with a score between 15 and 25 (IRR = 1.17; 95% CI 0.93–1.49) compared with those with a score of >25. Mean quality score varied across centers from 16.5 ± 7.5 to 29.1 ± 6.3. When the score was tested as the dependent variable, it emerged that 18% of the variance in the score could be attributed to setting characteristics. CONCLUSIONS Our study documented a close relationship between quality of diabetes care and long-term outcomes. A simple score can be used to monitor quality of care and compare the performance of different centers/physicians. PMID:21270192

  7. Patient-doctor interaction in rehabilitation: the relationship between perceived interaction quality and long-term treatment results.

    PubMed

    Dibbelt, Susanne; Schaidhammer, Monika; Fleischer, Christian; Greitemann, Bernhard

    2009-09-01

    dialogue on admission more positively showed stronger treatment effects with respect to pain as well as to anxiety at discharge and six months after discharge. Analysis for single scales of the P.A.INT-Questionnaire revealed that this is due to affective and instrumental quality of the dialogues. Our results suggest a correlation between perceived interaction quality, as defined by our questionnaire and treatment effects six months after discharge. Comparisons of patient and physician evaluations showed that physicians seem to be successful in building relationships on the affective level, but less successful on the instrumental level (i.e. information, structuring and reinforcement). They also perceive disturbances on the relational and organisational level more strongly than patients. Our data underline the importance of interaction quality for the success of rehabilitation and thus the importance of specific skills such as providing and collecting information, recognizing patients' concerns and goals as well as reinforcement of health related action. Regular training and supervision should be provided to support physicians and to enhance their competence in dealing with patients concerns.

  8. Quality improvement in pediatrics: past, present, and future.

    PubMed

    Schwartz, Stephanie P; Rehder, Kyle J

    2017-01-01

    Almost two decades ago, the landmark report "To Err is Human" compelled healthcare to address the large numbers of hospitalized patients experiencing preventable harm. Concurrently, it became clear that the rapidly rising cost of healthcare would be unsustainable in the long-term. As a result, quality improvement methodologies initially rooted in other high-reliability industries have become a primary focus of healthcare. Multiple pediatric studies demonstrate remarkable quality and safety improvements in several domains including handoffs, catheter-associated blood stream infections, and other serious safety events. While both quality improvement and research are data-driven processes, significant differences exist between the two. Research utilizes a hypothesis driven approach to obtain new knowledge while quality improvement often incorporates a cyclic approach to translate existing knowledge into clinical practice. Recent publications have provided guidelines and methods for effectively reporting quality and safety work and improvement implementations. This review examines not only how quality improvement in pediatrics has led to improved outcomes, but also looks to the future of quality improvement in healthcare with focus on education and collaboration to ensure best practice approaches to caring for children.

  9. Correlation between doctor's belief on the patient's self-determination and medical outcomes in obtaining informed consent.

    PubMed

    Yoshihara, Keisuke; Takase, Kozo

    2013-03-01

    We employed a questionnaire survey to assess attitudes toward informed consent (IC) among hospital doctors. Based on the result of the correlation analysis, the following two hypotheses were identified. The first hypothesis is that "the doctor's belief that the patient's self-determination is possible promotes cure of illness by obtaining IC." The second hypothesis is that "the doctor's belief that the patient's self-determination is possible has a positive influence on patient's quality of life by obtaining IC." We clarified the rationale for explaining these two hypotheses by applying cross tabulation analysis, discriminant analysis and principal component analysis (PCA). The doctors were divided into two groups in terms of their position on the patient's self-determination. One group of doctors believed the possibility of patient's self-determination, and the other did not. Through our statistical analyses, the characteristics that discriminate these two groups were identified. It was revealed that the former group placed a great importance on the hospitality value, while the latter placed an importance on the service value. Agreement or rejection of the concept of IC has been demonstrated as a key distinguishing factor between the two groups. The results of PCA showed that the doctor's belief on the patient's self-determination in obtaining IC had a significant effect on medical outcomes, and the two above-mentioned hypotheses were revealed.

  10. Data Assimilation Experiments using Quality Controlled AIRS Version 5 Temperature Soundings

    NASA Technical Reports Server (NTRS)

    Susskind, Joel

    2008-01-01

    The AIRS Science Team Version 5 retrieval algorithm has been finalized and is now operational at the Goddard DAAC in the processing (and reprocessing) of all AlRS data. Version 5 contains accurate case-by-case error estimates for most derived products, which are also used for quality control. We have conducted forecast impact experiments assimilating AlRS quality controlled temperature profiles using the NASA GEOS-5 data assimilation system, consisting of the NCEP GSI analysis coupled with the NASA FVGCM. Assimilation of quality controlled temperature profiles resulted in significantly improved forecast skill in both the Northern Hemisphere and Southern Hemisphere Extra-Tropics, compared to that obtained from analyses obtained when all data used operationally by NCEP except for AlRS data is assimilated. Experiments using different Quality Control thresholds for assimilation of AlRS temperature retrievals showed that a medium quality control threshold performed better than a tighter threshold, which provided better overall sounding accuracy; or a looser threshold, which provided better spatial coverage of accepted soundings. We are conducting more experiments to further optimize this balance of spatial coverage and sounding accuracy from the data assimilation perspective. In all cases, temperature soundings were assimilated well below cloud level in partially cloudy cases. The positive impact of assimilating AlRS derived atmospheric temperatures all but vanished when only AIRS stratospheric temperatures were assimilated. Forecast skill resulting from assimilation of AlRS radiances uncontaminated by clouds, instead of AlRS temperature soundings, was only slightly better than that resulting from assimilation of only stratospheric AlRS temperatures. This reduction in forecast skill is most likely the result of significant loss of tropospheric information when only AIRS radiances unaffected by clouds are used in the data assimilation process.

  11. Postgraduate Education in Quality Improvement Methods: Initial Results of the Fellows' Applied Quality Training (FAQT) Curriculum.

    PubMed

    Winchester, David E; Burkart, Thomas A; Choi, Calvin Y; McKillop, Matthew S; Beyth, Rebecca J; Dahm, Phillipp

    2016-06-01

    Training in quality improvement (QI) is a pillar of the next accreditation system of the Accreditation Committee on Graduate Medical Education and a growing expectation of physicians for maintenance of certification. Despite this, many postgraduate medical trainees are not receiving training in QI methods. We created the Fellows Applied Quality Training (FAQT) curriculum for cardiology fellows using both didactic and applied components with the goal of increasing confidence to participate in future QI projects. Fellows completed didactic training from the Institute for Healthcare Improvement's Open School and then designed and completed a project to improve quality of care or patient safety. Self-assessments were completed by the fellows before, during, and after the first year of the curriculum. The primary outcome for our curriculum was the median score reported by the fellows regarding their self-confidence to complete QI activities. Self-assessments were completed by 23 fellows. The majority of fellows (15 of 23, 65.2%) reported no prior formal QI training. Median score on baseline self-assessment was 3.0 (range, 1.85-4), which was significantly increased to 3.27 (range, 2.23-4; P = 0.004) on the final assessment. The distribution of scores reported by the fellows indicates that 30% were slightly confident at conducting QI activities on their own, which was reduced to 5% after completing the FAQT curriculum. An interim assessment was conducted after the fellows completed didactic training only; median scores were not different from the baseline (mean, 3.0; P = 0.51). After completion of the FAQT, cardiology fellows reported higher self-confidence to complete QI activities. The increase in self-confidence seemed to be limited to the applied component of the curriculum, with no significant change after the didactic component.

  12. The quality of raw water for drinking water unit in Jakarta-Indonesia

    NASA Astrophysics Data System (ADS)

    Sidabutar, Noni Valeria; Hartono, Djoko M.; Soesilo, Tri Edhi Budhi; Hutapea, Reynold C.

    2017-03-01

    Water problems, i.e quality, quantity, continuity of clean water faced by the mostly urban area. Jakarta also faces similar issues, because the needs of society higher than the number of water fulfilled by the government. Moreover, Jakarta's water quality does not meet the standard set by the Government and heavily polluted by anthropogenic activities along its rivers. This research employs a quantitative research approach with the mix-method. It examines the raw water quality status for drinking water in West Tarum Canalin 2011-2015. The research results show water quality with this research, using water quality of with the water categorized as heavily-polluted category based on the Ministry of Environment's Decree No 115/2003 regarding the Guidelines for Determination of Water Quality Status. This present research also shown the water quality (parameters pH, temperature, Dissolved Oxygen (DO), Chemical Oxygen Demand (COD), and Biochemical Oxygen Demand (BOD)) from Jatiluhur Dam to the intake drinking water unit. In thirteen points of sampling also, the results obtained the parameters DO, COD, and BOD are fluctuating and exceed the standard.

  13. Quality Assessment of Compounded 17-hydroxyprogesterone Caproate

    PubMed Central

    Chang, Justine; Zhao, Yang; Zhao, WenChen; Venkataramanan, Raman; Caritis, Steve N.

    2013-01-01

    Objective To evaluate the quality of compounded 17-hydroxyprogesterone caproate (17-OHPC) Study Design Compounded 17-OHPC was obtained from 15 compounding pharmacies throughout the U.S. and analyzed for potency, impurities, sterility, and pyrogen status. Results Eighteen samples were supplied by 15 compounding pharmacies. The concentration of 17-OHPC in all samples was within the specification limits and all tested samples passed sterility and pyrogen testing. Only 1 of 18 samples was out of specification limits for impurities. Conclusion Compounded 17-OHPC obtained from 15 pharmacies throughout the U.S. did not raise safety concerns when assessed for potency, sterility, pyrogen status or impurities. PMID:24200163

  14. Preface; Water quality of large U.S. rivers; results from the U.S. Geological Survey's National Stream Quality Accounting Network

    USGS Publications Warehouse

    Hirsch, Robert M.; Hooper, Richard P.; Kelly, Valerie J.

    2001-01-01

    The mission of the US Geological Survey (USGS) is to assess the quantity and quality of the earth resources of the USA and to provide information that will assist resource managers and policymakers at federal, state and local levels in making sound decisions. Characterizing the water quality of the largest rivers of the USA is a daunting prospect, especially given the resources available for the task. The most effective approach is uncertain and is legitimately a research topic. The National Stream Quality Accounting Network (NASQAN) was redesigned in 1995 to estimate the annual mass flux of constituents at a network of fixed stations in the Mississippi, Rio Grande, Colorado, and Columbia River basins. This special volume of Hydrological Processes contains a series of papers evaluating the data collected by NASQAN during its first 3 years of operation under this design. The NASQAN network complements other USGS national programs that are designed to address water quality at different scales. The National Water-Quality Assessment Program (Hirsch et al., 1988) is designed around river basins of 10 000 to 100 000 km2 (versus these NASQAN basins, which are 650 000 to 3 100 000 km2 at their most downstream stations). The USGS also operates the Hydrologic Benchmark Network that is focused on relatively pristine basins of only 10 to 100 km2 (Mast and Turk, 1999a,b; Clark et al., 2000; Mast et al., 2000).

  15. Transparent Reporting of Data Quality in Distributed Data Networks

    PubMed Central

    Kahn, Michael G.; Brown, Jeffrey S.; Chun, Alein T.; Davidson, Bruce N.; Meeker, Daniella; Ryan, Patrick B.; Schilling, Lisa M.; Weiskopf, Nicole G.; Williams, Andrew E.; Zozus, Meredith Nahm

    2015-01-01

    Introduction: Poor data quality can be a serious threat to the validity and generalizability of clinical research findings. The growing availability of electronic administrative and clinical data is accompanied by a growing concern about the quality of these data for observational research and other analytic purposes. Currently, there are no widely accepted guidelines for reporting quality results that would enable investigators and consumers to independently determine if a data source is fit for use to support analytic inferences and reliable evidence generation. Model and Methods: We developed a conceptual model that captures the flow of data from data originator across successive data stewards and finally to the data consumer. This “data lifecycle” model illustrates how data quality issues can result in data being returned back to previous data custodians. We highlight the potential risks of poor data quality on clinical practice and research results. Because of the need to ensure transparent reporting of a data quality issues, we created a unifying data-quality reporting framework and a complementary set of 20 data-quality reporting recommendations for studies that use observational clinical and administrative data for secondary data analysis. We obtained stakeholder input on the perceived value of each recommendation by soliciting public comments via two face-to-face meetings of informatics and comparative-effectiveness investigators, through multiple public webinars targeted to the health services research community, and with an open access online wiki. Recommendations: Our recommendations propose reporting on both general and analysis-specific data quality features. The goals of these recommendations are to improve the reporting of data quality measures for studies that use observational clinical and administrative data, to ensure transparency and consistency in computing data quality measures, and to facilitate best practices and trust in the new

  16. Quality of Rapeseed Bio-Fuel Waste: Optical Properties

    NASA Astrophysics Data System (ADS)

    Sujak, Agnieszka; Muszyñski, Siemowit; Kachel-Jakubowska, Magdalena

    2014-04-01

    The objective of the presented work was to examine the optical properties of selected bio-fuel waste. Three independent optical methods: UV-Vis spectroscopy, infrared spectroscopy and chromametric measurements were applied to establish the possible quality control test for the obtained substances. The following by-products were tested: distilled glycerine, technical glycerine and matter organic non glycerine fraction from rapeseed oil bio-fuel production. The results show that analysis of UV-Vis spectra can give rapid information about the purity of distilled glycerine, while no direct information can be obtained concerning the concentration and kind of impurities. Transmission mode is more useful as compared to absorption, concerning the detection abilities of average UV-Vis spectrometers. Infrared spectroscopy can be used as a complementary method for determining impurities/admixtures in samples. Measurements of chroma give the quickest data to compare the colour of biofuel by-products obtained by different producers. The condition is, however, that the products are received through the same or similar chemical processes. The other important factor is application of well defined measuring background. All the discussed analyses are quick, cheap and non-destructive, and can help to compare the quality of products.

  17. Quality assessment of the TLS data in conservation of monuments

    NASA Astrophysics Data System (ADS)

    Markiewicz, Jakub S.; Zawieska, Dorota

    2015-06-01

    Laser scanning has been recently confirming its high potential in the field of acquiring 3D data for architectural and engineering objects. The objective of this paper is to analyse the quality of the TLS data acquired for different surfaces of monumental objects, with consideration of distances and the scanning angles. Tests concerning the quality of the survey data and shapes of architectural objects, characterised by diversified curvature, structure and the uniformity of the surface, were performed. The obtained results proved that utilisation of terrestrial laser scanning techniques does not allow to achieve expected accuracy for some historical surfaces and it should be substituted by alternative, photogrammetric techniques. Therefore, the typology of constructions of historical objects is important not only for selection of the optimum technique of surveys, but also for its appropriate utilisation. The test objects were architectural details of the Main Hall of the Warsaw University of Technology. Scans were acquired using the 5006h scanner. Diversified geometry of scans was tested, and the relations between the distance and obtained accuracy were specified. In the case of numerous conservational works the precise surface reconstruction is often important, in order to specify damages. Therefore, the repeatability of obtained TLS results for selected surfaces was also tested. Different surfaces were analysed, which are composed of different materials having glittery elements and inhomogeneous structure. The obtained results and performed analyses revealed the high imperfections of the TLS technique applied for measuring surfaces of historical objects. The presented accuracy of measurements of projection of historical surfaces, obtained using the TLS technique may be applied by art conservators, museum professionals, archaeologists and other specialists, to perform wide analyses of historical heritage objects.

  18. Portable water quality monitoring system

    NASA Astrophysics Data System (ADS)

    Nizar, N. B.; Ong, N. R.; Aziz, M. H. A.; Alcain, J. B.; Haimi, W. M. W. N.; Sauli, Z.

    2017-09-01

    Portable water quality monitoring system was a developed system that tested varied samples of water by using different sensors and provided the specific readings to the user via short message service (SMS) based on the conditions of the water itself. In this water quality monitoring system, the processing part was based on a microcontroller instead of Lead and Copper Rule (LCR) machines to receive the results. By using four main sensors, this system obtained the readings based on the detection of the sensors, respectively. Therefore, users can receive the readings through SMS because there was a connection between Arduino Uno and GSM Module. This system was designed to be portable so that it would be convenient for users to carry it anywhere and everywhere they wanted to since the processor used is smaller in size compared to the LCR machines. It was also developed to ease the user to monitor and control the water quality. However, the ranges of the sensors' detection still a limitation in this study.

  19. Training, Quality Assurance Factors, and Tools Investigation: a Work Report and Suggestions on Software Quality Assurance

    NASA Technical Reports Server (NTRS)

    Lee, Pen-Nan

    1991-01-01

    Previously, several research tasks have been conducted, some observations were obtained, and several possible suggestions have been contemplated involving software quality assurance engineering at NASA Johnson. These research tasks are briefly described. Also, a brief discussion is given on the role of software quality assurance in software engineering along with some observations and suggestions. A brief discussion on a training program for software quality assurance engineers is provided. A list of assurance factors as well as quality factors are also included. Finally, a process model which can be used for searching and collecting software quality assurance tools is presented.

  20. 75 FR 47777 - Certain Cut-to-Length Carbon-Quality Steel Plate Products From Italy: Final Results of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-09

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-475-826] Certain Cut-to-Length Carbon... administrative review of the antidumping duty order on certain cut-to-length carbon-quality steel plate products... the preliminary results of the administrative review of the antidumping duty order on certain cut-to...

  1. Beef quality parameters estimation using ultrasound and color images

    PubMed Central

    2015-01-01

    Background Beef quality measurement is a complex task with high economic impact. There is high interest in obtaining an automatic quality parameters estimation in live cattle or post mortem. In this paper we set out to obtain beef quality estimates from the analysis of ultrasound (in vivo) and color images (post mortem), with the measurement of various parameters related to tenderness and amount of meat: rib eye area, percentage of intramuscular fat and backfat thickness or subcutaneous fat. Proposal An algorithm based on curve evolution is implemented to calculate the rib eye area. The backfat thickness is estimated from the profile of distances between two curves that limit the steak and the rib eye, previously detected. A model base in Support Vector Regression (SVR) is trained to estimate the intramuscular fat percentage. A series of features extracted on a region of interest, previously detected in both ultrasound and color images, were proposed. In all cases, a complete evaluation was performed with different databases including: color and ultrasound images acquired by a beef industry expert, intramuscular fat estimation obtained by an expert using a commercial software, and chemical analysis. Conclusions The proposed algorithms show good results to calculate the rib eye area and the backfat thickness measure and profile. They are also promising in predicting the percentage of intramuscular fat. PMID:25734452

  2. Implementation of a quality improvement initiative in Belgian diabetic foot clinics: feasibility and initial results.

    PubMed

    Doggen, Kris; Van Acker, Kristien; Beele, Hilde; Dumont, Isabelle; Félix, Patricia; Lauwers, Patrick; Lavens, Astrid; Matricali, Giovanni A; Randon, Caren; Weber, Eric; Van Casteren, Viviane; Nobels, Frank

    2014-07-01

    This article aims to describe the implementation and initial results of an audit-feedback quality improvement initiative in Belgian diabetic foot clinics. Using self-developed software and questionnaires, diabetic foot clinics collected data in 2005, 2008 and 2011, covering characteristics, history and ulcer severity, management and outcome of the first 52 patients presenting with a Wagner grade ≥ 2 diabetic foot ulcer or acute neuropathic osteoarthropathy that year. Quality improvement was encouraged by meetings and by anonymous benchmarking of diabetic foot clinics. The first audit-feedback cycle was a pilot study. Subsequent audits, with a modified methodology, had increasing rates of participation and data completeness. Over 85% of diabetic foot clinics participated and 3372 unique patients were sampled between 2005 and 2011 (3312 with a diabetic foot ulcer and 111 with acute neuropathic osteoarthropathy). Median age was 70 years, median diabetes duration was 14 years and 64% were men. Of all diabetic foot ulcers, 51% were plantar and 29% were both ischaemic and deeply infected. Ulcer healing rate at 6 months significantly increased from 49% to 54% between 2008 and 2011. Management of diabetic foot ulcers varied between diabetic foot clinics: 88% of plantar mid-foot ulcers were off-loaded (P10-P90: 64-100%), and 42% of ischaemic limbs were revascularized (P10-P90: 22-69%) in 2011. A unique, nationwide quality improvement initiative was established among diabetic foot clinics, covering ulcer healing, lower limb amputation and many other aspects of diabetic foot care. Data completeness increased, thanks in part to questionnaire revision. Benchmarking remains challenging, given the many possible indicators and limited sample size. The optimized questionnaire allows future quality of care monitoring in diabetic foot clinics. Copyright © 2014 John Wiley & Sons, Ltd.

  3. Surface morphology of ultrathin graphene oxide films obtained by the SAW atomization

    NASA Astrophysics Data System (ADS)

    Balachova, Olga V.; Balashov, Sergey M.; Costa, Carlos A. R.; Pavani Filho, A.

    2015-08-01

    Lately, graphene oxide (GO) thin films have attracted much attention: they can be used as humidity-sensitive coatings in the surface acoustic wave (SAW) sensors; being functionalized, they can be used in optoelectronic or biodevices, etc. In this research we study surface morphology of small-area thin GO films obtained on Si and quartz substrates by deposition of very small amounts of H2O-GO aerosols produced by the SAW atomizer. An important feature of this method is the ability to work with submicrovolumes of liquids during deposition that provides relatively good control over the film thickness and quality, in particular, minimization of the coffee ring effect. The obtained films were examined using AFM and electron microscopy. Image analysis showed that the films consist of GO sheets of different geometry and sizes and may form discrete or continuous coatings at the surface of the substrates with the minimum thickness of 1.0-1.8 nm which corresponds to one or two monolayers of GO. The thickness and quality of the deposited films depend on the parameters of the SAW atomization (number of atomized droplets, a volume of the initial droplet, etc.) and on sample surface preparation (activation in oxygen plasma). We discuss the structure of the obtained films, uniformity and the surface coverage as a function of parameters of the film deposition process and sample preparation. Qualitative analysis of adhesion of GO films is made by rinsing the samples in DI water and subsequent evaluation of morphology of the remained films.

  4. Quality standards for predialysis education: results from a consensus conference

    PubMed Central

    Isnard Bagnis, Corinne; Crepaldi, Carlo; Dean, Jessica; Goovaerts, Tony; Melander, Stefan; Nilsson, Eva-Lena; Prieto-Velasco, Mario; Trujillo, Carmen; Zambon, Roberto; Mooney, Andrew

    2015-01-01

    This position statement was compiled following an expert meeting in March 2013, Zurich, Switzerland. Attendees were invited from a spread of European renal units with established and respected renal replacement therapy option education programmes. Discussions centred around optimal ways of creating an education team, setting realistic and meaningful objectives for patient education, and assessing the quality of education delivered. PMID:24957808

  5. Diet quality and sleep quality among day and night shift nurses.

    PubMed

    Beebe, Deborah; Chang, Jen Jen; Kress, Kathleen; Mattfeldt-Beman, Mildred

    2017-10-01

    To determine whether night shift workers have a poorer diet quality and sleep quality when compared with day shift nurses. There is a dearth of research investigating the association between diet quality and sleep quality of day and night shift nurses. Data on nurses (n = 103) working either a day or night shift from two Midwestern hospitals were obtained from August 2015 to February 2016. The instruments used were the Diet History Questionnaire and the Pittsburg Sleep Quality Index. Independent samples t-tests were used to examine differences in diet and sleep quality by work shift schedule. There were no statistically significant differences between nurses working day or night shift and sleep quality (P = 0.0684), as well as diet quality (P = 0.6499). There was a significant difference between both body mass index (P = 0.0014) and exercise (P = 0.0020) with regard to diet quality. Body mass index and sleep quality were also significantly associated (P = 0.0032). Our study found no differences between day and night shift with regard to sleep and diet quality among nurses. Deliberate health initiatives and wellness programmes specifically targeting nurses are needed to increase knowledge about maintaining a healthy lifestyle while working as a nurse, whether it is day or night shift. © 2017 John Wiley & Sons Ltd.

  6. SU-F-P-15: Report On AAPM TG 178 Gamma Knife Dosimetry and Quality Assurance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goetsch, S

    Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocolmore » modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers Conclusion: The full TG 178 report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics. Consultant to Elekta, Inc.« less

  7. Landsat image data quality studies

    NASA Technical Reports Server (NTRS)

    Schueler, C. F.; Salomonson, V. V.

    1985-01-01

    Preliminary results of the Landsat-4 Image Data Quality Analysis (LIDQA) program to characterize the data obtained using the Thematic Mapper (TM) instrument on board the Landsat-4 and Landsat-5 satellites are reported. TM design specifications were compared to the obtained data with respect to four criteria, including spatial resolution; geometric fidelity; information content; and image relativity to Multispectral Scanner (MSS) data. The overall performance of the TM was rated excellent despite minor instabilities and radiometric anomalies in the data. Spatial performance of the TM exceeded design specifications in terms of both image sharpness and geometric accuracy, and the image utility of the TM data was at least twice as high as MSS data. The separability of alfalfa and sugar beet fields in a TM image is demonstrated.

  8. Voice Quality Modelling for Expressive Speech Synthesis

    PubMed Central

    Socoró, Joan Claudi

    2014-01-01

    This paper presents the perceptual experiments that were carried out in order to validate the methodology of transforming expressive speech styles using voice quality (VoQ) parameters modelling, along with the well-known prosody (F 0, duration, and energy), from a neutral style into a number of expressive ones. The main goal was to validate the usefulness of VoQ in the enhancement of expressive synthetic speech in terms of speech quality and style identification. A harmonic plus noise model (HNM) was used to modify VoQ and prosodic parameters that were extracted from an expressive speech corpus. Perception test results indicated the improvement of obtained expressive speech styles using VoQ modelling along with prosodic characteristics. PMID:24587738

  9. Approaches to quality management and accreditation in a genetic testing laboratory

    PubMed Central

    Berwouts, Sarah; Morris, Michael A; Dequeker, Elisabeth

    2010-01-01

    Medical laboratories, and specifically genetic testing laboratories, provide vital medical services to different clients: clinicians requesting a test, patients from whom the sample was collected, public health and medical-legal instances, referral laboratories and authoritative bodies. All expect results that are accurate and obtained in an efficient and effective manner, within a suitable time frame and at acceptable cost. There are different ways of achieving the end results, but compliance with International Organization for Standardization (ISO) 15189, the international standard for the accreditation of medical laboratories, is becoming progressively accepted as the optimal approach to assuring quality in medical testing. We present recommendations and strategies designed to aid genetic testing laboratories with the implementation of a quality management system, including key aspects such as document control, external quality assessment, internal quality control, internal audit, management review, validation, as well as managing the human side of change. The focus is on pragmatic approaches to attain the levels of quality management and quality assurance required for accreditation according to ISO 15189, within the context of genetic testing. Attention is also given to implementing efficient and effective quality improvement. PMID:20720559

  10. Physical occupational exposures during working life and quality of life after labour market exit: results from the GAZEL study

    PubMed Central

    Platts, Loretta; Netuveli, Gopalakrishnan; Webb, Elizabeth; Zins, Marie; Goldberg, Marcel; Blane, David; Wahrendorf, Morten

    2013-01-01

    Objective To investigate variations in quality of life at older ages we take a life course perspective to analyse long-term effects of physical working conditions upon quality of life after retirement. In doing so, we study to what extent these associations are explained by individuals’ health at older ages. Method We use administrative data and self-administered questionnaire responses from the French GAZEL cohort. Quality of life was assessed with CASP-19 in 2009 and related to three types of physical working conditions during previous working life: (1) ergonomic strain, (2) physical danger and (3) exposures to chemicals. Health was assessed in 2007 with the SF-36 Health Survey. Multiple regressions were calculated in retired men only, controlling for important confounders including social position. Results In contrast to men, few women were exposed to strenuous and dangerous working conditions in this cohort and were not included in subsequent analyses. Negative effects on retired men’s quality of life were found for the physical occupational exposures of ergonomic strain and physical danger, but not for chemical exposures. Effects were attenuated after the introduction of physical and mental health to the models, indicating an indirect effect of physical working conditions upon quality of life via health. Conclusion Adverse physical working conditions have long-term consequences for health and quality of life at older ages. Improvements to physical working conditions may improve individuals’ quality of life over the long term. PMID:23560563

  11. Study of the suitability of a commercial hydroxyapatite powder to obtain sintered compacts for medical applications

    NASA Astrophysics Data System (ADS)

    Palacio, C.; Jaramillo, D.; Correa, S.; Arroyave, M.

    2017-06-01

    Hydroxyapatite (HA) is a material widely used by the medical community due to its Ca/P ratio is comparable to the Ca/P ratio of bones and teeth, which promotes osteoinduction and osteoconduction processes when in contact with bone tissue, either as volume piece or coating. This work focuses on studying the quality of the commercial HA powder MKnano-#MKN-HXAP-S12 µm, after processing, to obtain sintered compact discs with suitable physical and chemical characteristics for implants applications. The HA powder was processed through calcination, grinding, pressing and sintering to evaluate the effect of such as procedures in the compacts dics quality. The raw powder was characterized by laser diffraction, SEM, XRF, XRD, TGA and DSC while the characteristics of the obtained compact discs were determined by dilatometry and XRD to identify the sintering temperature range, constituent phases, the amorphous content and the crystallinity degree, parameters that allow determining their suitability for implants applications. Although, it was not possible to obtain sintered compacts with the suitable chemical composition and without fractures, this work allowed to identify the parameters that determine the suitability of a HA powder to obtain sintered compacts for medical applications, as well as the characterization protocol that allows the evaluation of such parameters.

  12. Integrity Model Application: A Quality Support System for Decision-makers on Water Quality Assessment and Improvement

    NASA Astrophysics Data System (ADS)

    Mirauda, D.; Ostoich, M.; Di Maria, F.; Benacchio, S.; Saccardo, I.

    2018-03-01

    In this paper, a mathematical model has been applied to a river in North-East Italy to describe vulnerability scenarios due to environmental pollution phenomena. Such model, based on the influence diagrams theory, allowed identifying the extremely critical factors, such as wastewater discharges, drainage of diffuse pollution from agriculture and climate changes, which might affect the water quality of the river. The obtained results underlined how the water quality conditions have improved thanks to the continuous controls on the territory, following the application of Water Framework Directive 2000/60/EC. Nevertheless, some fluvial stretches did not reach the “good ecological status” by 2015, because of the increasing population in urban areas recorded in the last years and the high presence of tourists during the summer months, not balanced by a treatment plants upgrade.

  13. Water quality evaluation of Al-Gharraf river by two water quality indices

    NASA Astrophysics Data System (ADS)

    Ewaid, Salam Hussein

    2017-11-01

    Water quality of Al-Gharraf river, the largest branch of Tigris River south of Iraq, was evaluated by the National Sanitation Foundation Water Quality Index (NFS WQI) and the Heavy Metal Pollution Index (HPI) depending on 13 physical, chemical, and biological parameters of water quality measured monthly at ten stations on the river during 2015. The NSF-WQI range obtained for the sampling sites was 61-70 indicating a medium water quality. The HPI value was 98.6 slightly below the critical value for drinking water of 100, and the water quality in the upstream stations is better than downstream due to decrease in water and the accumulation of contaminants along the river. This study explains the significance of applying the water quality indices that show the aggregate impact of ecological factors in charge of water pollution of surface water and which permits translation of the monitoring data to assist the decision makers.

  14. Ground-Water Quality Data in the Kern County Subbasin Study Unit, 2006 - Results from the California GAMA Program

    USGS Publications Warehouse

    Shelton, Jennifer L.; Pimentel, Isabel; Fram, Miranda S.; Belitz, Kenneth

    2008-01-01

    the wells, and the results for these samples were used to evaluate the quality of the data from the ground-water samples. Assessment of the quality-control information resulted in censoring of less than 0.4 percent of the data collected for ground-water samples. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, raw ground water typically is treated, disinfected, or blended with other waters to maintain acceptable water quality. Regulatory thresholds apply, not to the raw ground water, but to treated water that is served to the consumer. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and the California Department of Public Health (CDPH), and as well as with thresholds established for aesthetic concerns (secondary maximum contaminant levels, SMCL-CA) by CDPH. VOCs and pesticides each were detected in approximately 60 percent of the grid wells, and detections of all compounds but one were below health-based thresholds. The fumigant, 1,2-dibromo-3-chloropropane (DBCP), was detected above the USEPA maximum contaminant level (MCL-US) in one sample. Detections of most inorganic constituents were also below health-based thresholds. Constituents detected above health-based thresholds include: nitrate, (MCL-US, 2 samples), arsenic (MCL-US, 2 samples), and vanadium (California notification level, NL-CA, 1 sample). All detections of radioactive constituents were below health-based thresholds, although nine samples had activities of radon-222 above the lower proposed MCL-US. Most of the samples from KERN wells had concentrations of major elements, total dissolved solids, and trace elements below the non-enforceable thresholds set for aesthetic concerns.

  15. Production and characterization of refined oils obtained from Indian oil sardine (Sardinella longiceps).

    PubMed

    Chakraborty, Kajal; Joseph, Deepu

    2015-01-28

    Crude Sardinella longiceps oil was refined in different stages such as degumming, neutralization, bleaching, and deodorization. The efficiency of these processes was evaluated on the basis of free fatty acid (FFA), peroxide (PV), p-anisidine (pAV), total oxidation (TOTOX), thiobarbituric acid reactive species (TBARS) values, Lovibond CIE-L*a*b* color analyses, and (1)H NMR or GC-MS experiments. The utilities of NMR-based proton signal characteristics as new analytical tools to understand the signature peaks and relative abundance of different fatty acids and monitoring the refining process of fish oil have been demonstrated. Phosphoric acid (1%) was found to be an effective degumming reagent to obtain oil with the lowest FFA, PV, pAV, TOTOX, and TBARS values and highest color reduction. Significant reduction in the contents of hydrocarbon functionalities as shown by the decrease in proton integral in the characteristic (1)H NMR region was demonstrated by using 1% H3PO4 during the course of the degumming process. A combination (1.25:3.75%) of activated charcoal and Fuller's earth at 3% concentration for a stirring time of 40 min was found to be effective in bleaching the sardine oil. This study demonstrated that unfavorable odor-causing components, particularly low molecular weight carbonyl compounds, could successfully be removed by the refining process. The alkane-dienals/alkanes, which cause unfavorable fishy odors, were successfully removed by distillation (100 °C) under vacuum with aqueous acetic acid solution (0.25 N) to obtain greater quality of refined sardine oil, a rich source of essential fatty acids and improved oxidative stability. The present study demonstrated that the four-stage refinement process of sardine oil resulted in a significant improvement in quality characteristics and nutritional values, particularly n-3 PUFAs, with improved fish oil characteristics for use in the pharmaceutical and functional food industries.

  16. Quality Circles: Involvement, Problem-Solving, and Recognition.

    ERIC Educational Resources Information Center

    Moretz, H. Lynn

    1983-01-01

    The media production department of Central Piedmont Community College (CPCC) began quality circle meetings in January 1981 after studying the process of quality circles and obtaining the understanding and support of the college administration. A quality circle is a small group of people doing similar work who voluntarily meet on a regular basis to…

  17. Obtaining orthotropic elasticity tensor using entries zeroing method.

    NASA Astrophysics Data System (ADS)

    Gierlach, Bartosz; Danek, Tomasz

    2017-04-01

    A generally anisotropic elasticity tensor obtained from measurements can be represented by a tensor belonging to one of eight material symmetry classes. Knowledge of symmetry class and orientation is helpful for describing physical properties of a medium. For each non-trivial symmetry class except isotropic this problem is nonlinear. A common method of obtaining effective tensor is a choosing its non-trivial symmetry class and minimizing Frobenius norm between measured and effective tensor in the same coordinate system. Global optimization algorithm has to be used to determine the best rotation of a tensor. In this contribution, we propose a new approach to obtain optimal tensor, with the assumption that it is orthotropic (or at least has a similar shape to the orthotropic one). In orthotropic form tensor 24 out of 36 entries are zeros. The idea is to minimize the sum of squared entries which are supposed to be equal to zero through rotation calculated with optimization algorithm - in this case Particle Swarm Optimization (PSO) algorithm. Quaternions were used to parametrize rotations in 3D space to improve computational efficiency. In order to avoid a choice of local minima we apply PSO several times and only if we obtain similar results for the third time we consider it as a correct value and finish computations. To analyze obtained results Monte-Carlo method was used. After thousands of single runs of PSO optimization, we obtained values of quaternion parts and plot them. Points concentrate in several points of the graph following the regular pattern. It suggests the existence of more complex symmetry in the analyzed tensor. Then thousands of realizations of generally anisotropic tensor were generated - each tensor entry was replaced with a random value drawn from normal distribution having a mean equal to measured tensor entry and standard deviation of the measurement. Each of these tensors was subject of PSO based optimization delivering quaternion for optimal

  18. Does labour market disadvantage help to explain why childhood circumstances are related to quality of life at older ages? Results from SHARE

    PubMed Central

    Wahrendorf, Morten; Blane, David

    2015-01-01

    There is robust evidence that childhood circumstances are related to quality of life in older ages, but the role of possible intermediate factors is less explored. In this paper, we examine to what extent associations between deprived childhood circumstances and quality of life at older ages are due to experienced labour market disadvantage during adulthood. Analyses are based on the Survey of Health Ageing and Retirement in Europe (SHARE), with detailed retrospective information on individual life courses collected among 10,272 retired men and women in 13 European countries (2008–2009). Our assumption is that those who have spent their childhood in deprived circumstances may also have had more labour market disadvantage with negative consequences for quality of life beyond working life. Results demonstrate that advantaged circumstances during childhood are associated with lower levels of labour market disadvantage and higher quality of life in older ages. Furthermore, results of multivariate analyses support the idea that part of the association between childhood circumstances and later quality of life is explained by labour market disadvantage during adulthood. PMID:25033373

  19. Does labour market disadvantage help to explain why childhood circumstances are related to quality of life at older ages? Results from SHARE.

    PubMed

    Wahrendorf, Morten; Blane, David

    2015-07-01

    There is robust evidence that childhood circumstances are related to quality of life in older ages, but the role of possible intermediate factors is less explored. In this paper, we examine to what extent associations between deprived childhood circumstances and quality of life at older ages are due to experienced labour market disadvantage during adulthood. Analyses are based on the Survey of Health Ageing and Retirement in Europe (SHARE), with detailed retrospective information on individual life courses collected among 10,272 retired men and women in 13 European countries (2008-2009). Our assumption is that those who have spent their childhood in deprived circumstances may also have had more labour market disadvantage with negative consequences for quality of life beyond working life. Results demonstrate that advantaged circumstances during childhood are associated with lower levels of labour market disadvantage and higher quality of life in older ages. Furthermore, results of multivariate analyses support the idea that part of the association between childhood circumstances and later quality of life is explained by labour market disadvantage during adulthood.

  20. Analysis of ETMS Data Quality for Traffic Flow Management Decisions

    NASA Technical Reports Server (NTRS)

    Chatterji, Gano B.; Sridhar, Banavar; Kim, Douglas

    2003-01-01

    The data needed for air traffic flow management decision support tools is provided by the Enhanced Traffic Management System (ETMS). This includes both the tools that are in current use and the ones being developed for future deployment. Since the quality of decision support provided by all these tools will be influenced by the quality of the input ETMS data, an assessment of ETMS data quality is needed. Motivated by this desire, ETMS data quality is examined in this paper in terms of the unavailability of flight plans, deviation from the filed flight plans, departure delays, altitude errors and track data drops. Although many of these data quality issues are not new, little is known about their extent. A goal of this paper is to document the magnitude of data quality issues supported by numerical analysis of ETMS data. Guided by this goal, ETMS data for a 24-hour period were processed to determine the number of aircraft with missing flight plan messages at any given instant of time. Results are presented for aircraft above 18,000 feet altitude and also at all altitudes. Since deviation from filed flight plan is also a major cause of trajectory-modeling errors, statistics of deviations are presented. Errors in proposed departure times and ETMS-generated vertical profiles are also shown. A method for conditioning the vertical profiles for improving demand prediction accuracy is described. Graphs of actual sector counts obtained using these vertical profiles are compared with those obtained using the Host data for sectors in the Fort Worth Center to demonstrate the benefit of preprocessing. Finally, results are presented to quantify the extent of data drops. A method for propagating track positions during ETMS data drops is also described.

  1. Implementing self sustained quality control procedures in a clinical laboratory.

    PubMed

    Khatri, Roshan; K C, Sanjay; Shrestha, Prabodh; Sinha, J N

    2013-01-01

    Quality control is an essential component in every clinical laboratory which maintains the excellence of laboratory standards, supplementing to proper disease diagnosis, patient care and resulting in overall strengthening of health care system. Numerous quality control schemes are available, with combinations of procedures, most of which are tedious, time consuming and can be "too technical" whereas commercially available quality control materials can be expensive especially for laboratories in developing nations like Nepal. Here, we present a procedure performed at our centre with self prepared control serum and use of simple statistical tools for quality assurance. The pooled serum was prepared as per guidelines for preparation of stabilized liquid quality control serum from human sera. Internal Quality Assessment was performed on this sample, on a daily basis which included measurement of 12 routine biochemical parameters. The results were plotted on Levey-Jennings charts and analysed with quality control rules, for a period of one month. The mean levels of biochemical analytes in self prepared control serum were within normal physiological range. This serum was evaluated every day along with patients' samples. The results obtained were plotted on control charts and analysed using common quality control rules to identify possible systematic and random errors. Immediate mitigation measures were taken and the dispatch of erroneous reports was avoided. In this study we try to highlight on a simple internal quality control procedure which can be performed by laboratories, with minimum technology, expenditure, and expertise and improve reliability and validity of the test reports.

  2. Qualities of a good Singaporean psychiatrist: Qualitative differences between psychiatrists and patients.

    PubMed

    Tor, Phern-Chern; Tan, Jacinta O A

    2015-06-01

    Pilot studies in Singapore established four themes (personal values, professional, relationship, academic-executive) relating to the qualities of a good psychiatrist, and suggested potential differences of opinion between patients and psychiatrists. We sought to explore differences between patients and psychiatrists regarding the qualities of a good psychiatrist. Qualitative analysis of interviews using a modified grounded theory approach with 21 voluntary psychiatric inpatients and 18 psychiatrists. One hundred thirty-one separate qualities emerged from the data. The qualities of a good psychiatrist were viewed in the context of motivations, functions, methods, and results obtained, mirroring the themes established in the pilot studies. Patients and psychiatrists mostly concurred on the qualities of a good psychiatrist, with 62.6% of the qualities emerging from both groups. However significant differences existed. Patient-specific qualities included proof of altruistic motives, diligence, clinical competence, and positive results. What the psychiatrist represented to patients in relation to gender, culture, and clinical prestige also mattered to patients. Psychiatrist-specific qualities related to societal (e.g. public protection) and professional concerns (e.g. boundary issues). The results of this study demonstrate that patients and psychiatrists have different views about the qualities of a good psychiatrist. Patients may expect proof of care, diligence, and competence from the psychiatrist, along with positive results. In addition, psychiatrists should be mindful of what they represent to patients and how that can impact the doctor-patient relationship. © 2014 Wiley Publishing Asia Pty Ltd.

  3. Colorado Employability Skills Survey. Report of Results.

    ERIC Educational Resources Information Center

    Hulsart, Richard; Bauman, Paul

    Interviews were conducted with employers and military personnel to obtain information regarding basic skills needed in entry-level jobs available to young people with a high school education. Information was also obtained from young entry-level employees and military recruits on the quality of their high school preparation in basic employment…

  4. Telephone-quality pathological speech classification using empirical mode decomposition.

    PubMed

    Kaleem, M F; Ghoraani, B; Guergachi, A; Krishnan, S

    2011-01-01

    This paper presents a computationally simple and effective methodology based on empirical mode decomposition (EMD) for classification of telephone quality normal and pathological speech signals. EMD is used to decompose continuous normal and pathological speech signals into intrinsic mode functions, which are analyzed to extract physically meaningful and unique temporal and spectral features. Using continuous speech samples from a database of 51 normal and 161 pathological speakers, which has been modified to simulate telephone quality speech under different levels of noise, a linear classifier is used with the feature vector thus obtained to obtain a high classification accuracy, thereby demonstrating the effectiveness of the methodology. The classification accuracy reported in this paper (89.7% for signal-to-noise ratio 30 dB) is a significant improvement over previously reported results for the same task, and demonstrates the utility of our methodology for cost-effective remote voice pathology assessment over telephone channels.

  5. Interventions for obtaining and maintaining employment in adults with severe mental illness, a network meta-analysis.

    PubMed

    Suijkerbuijk, Yvonne B; Schaafsma, Frederieke G; van Mechelen, Joost C; Ojajärvi, Anneli; Corbière, Marc; Anema, Johannes R

    2017-09-12

    care only (RR 1.00,95% CI 0.51 to 1.96; SUCRA 17.2, low-quality evidence) in achieving competitive employment, but prevocational training stood out in the SUCRA value and rank.Augmented supported employment was slightly better than supported employment, but not significantly (RR 1.40, 95% CI 0.92 to 2.14). The SUCRA value and mean rank were higher for augmented supported employment.The results of the network meta-analysis of the intervention subgroups favoured augmented supported employment interventions, but also cognitive training. However, supported employment augmented with symptom-related skills training showed the best results (RR compared to psychiatric care only 3.61 with 95% CI 1.03 to 12.63, SUCRA 80.3).We graded the quality of the evidence of the network ranking as very low because of potential risk of bias in the included studies, inconsistency and publication bias. Direct meta-analysis of maintaining competitive employment Based on the direct meta-analysis of the short-term follow-up of maintaining employment, supported employment was more effective than: psychiatric care only, transitional employment, prevocational training, and augmented supported employment.In the long-term follow-up direct meta-analysis, augmented supported employment was more effective than prevocational training (MD 22.79 weeks, 95% CI 15.96 to 29.62) and supported employment (MD 10.09, 95% CI 0.32 to 19.85) in maintaining competitive employment. Participants receiving supported employment worked more weeks than those receiving transitional employment (MD 17.36, 95% CI 11.53 to 23.18) or prevocational training (MD 11.56, 95% CI 5.99 to 17.13).We did not find differences between interventions in the risk of dropouts or hospital admissions. Supported employment and augmented supported employment were the most effective interventions for people with severe mental illness in terms of obtaining and maintaining employment, based on both the direct comparison analysis and the network meta

  6. Sources of Traffic and Visitors’ Preferences Regarding Online Public Reports of Quality: Web Analytics and Online Survey Results

    PubMed Central

    Hibbard, Judith H; Greaves, Felix; Dudley, R Adams

    2015-01-01

    Background In the context of the Affordable Care Act, there is extensive emphasis on making provider quality transparent and publicly available. Online public reports of quality exist, but little is known about how visitors find reports or about their purpose in visiting. Objective To address this gap, we gathered website analytics data from a national group of online public reports of hospital or physician quality and surveyed real-time visitors to those websites. Methods Websites were recruited from a national group of online public reports of hospital or physician quality. Analytics data were gathered from each website: number of unique visitors, method of arrival for each unique visitor, and search terms resulting in visits. Depending on the website, a survey invitation was launched for unique visitors on landing pages or on pages with quality information. Survey topics included type of respondent (eg, consumer, health care professional), purpose of visit, areas of interest, website experience, and demographics. Results There were 116,657 unique visitors to the 18 participating websites (1440 unique visitors/month per website), with most unique visitors arriving through search (63.95%, 74,606/116,657). Websites with a higher percent of traffic from search engines garnered more unique visitors (P=.001). The most common search terms were for individual hospitals (23.25%, 27,122/74,606) and website names (19.43%, 22,672/74,606); medical condition terms were uncommon (0.81%, 605/74,606). Survey view rate was 42.48% (49,560/116,657 invited) resulting in 1755 respondents (participation rate=3.6%). There were substantial proportions of consumer (48.43%, 850/1755) and health care professional respondents (31.39%, 551/1755). Across websites, proportions of consumer (21%-71%) and health care professional respondents (16%-48%) varied. Consumers were frequently interested in using the information to choose providers or assess the quality of their provider (52.7%, 225

  7. Models and Methods of Aggregating Linguistic Information in Multi-criteria Hierarchical Quality Assessment Systems

    NASA Astrophysics Data System (ADS)

    Azarnova, T. V.; Titova, I. A.; Barkalov, S. A.

    2018-03-01

    The article presents an algorithm for obtaining an integral assessment of the quality of an organization from the perspective of customers, based on the method of aggregating linguistic information on a multilevel hierarchical system of quality assessment. The algorithm is of a constructive nature, it provides not only the possibility of obtaining an integral evaluation, but also the development of a quality improvement strategy based on the method of linguistic decomposition, which forms the minimum set of areas of work with clients whose quality change will allow obtaining the required level of integrated quality assessment.

  8. Geochemical evolution processes and water-quality observations based on results of the National Water-Quality Assessment Program in the San Antonio segment of the Edwards aquifer, 1996-2006

    USGS Publications Warehouse

    Musgrove, MaryLynn; Fahlquist, Lynne; Houston, Natalie A.; Lindgren, Richard J.; Ging, Patricia B.

    2010-01-01

    increase along flow paths; results for samples of Edwards aquifer groundwater show an increase from shallow/urban unconfined, to unconfined, to confined groundwater categories. These differences are consistent with longer residence times and greater extents of water-rock interaction controlling fluid compositions as groundwater evolves from shallow unconfined groundwater to deeper confined groundwater. Results for stable isotopes of hydrogen and oxygen indicate specific geochemical processes affect some groundwater samples, including mixing with downdip saline water, mixing with recent recharge associated with tropical cyclonic storms, or mixing with recharge water than has undergone evaporation. The composition of surface water recharging the aquifer, as well as mixing with downdip water from the Trinity aquifer or the saline zone, also might affect water quality. A time-series record (1938-2006) of discharge at Comal Springs, one of the major aquifer discharge points, indicates an upward trend for nitrate and chloride concentrations, which likely reflects anthropogenic activities. A small number of organic contaminants were routinely or frequently detected in Edwards aquifer groundwater samples. These were the pesticides atrazine, its degradate deethylatrazine, and simazine; the drinking-water disinfection byproduct chloroform; and the solvent tetrachloroethene. Detection of these contaminants was most frequent in samples of the shallow/urban unconfined groundwater category and least frequent in samples of the unconfined groundwater category. Results indicate that the shallow/urban unconfined part of the aquifer is most affected by anthropogenic contaminants and the unconfined part of the aquifer is the least affected. The high frequency of detection for these anthropogenic contaminants aquifer-wide and in samples of deep, confined groundwater indicates that the entire aquifer is susceptible to water-quality changes as a result of anthropogenic activities. L

  9. Quality-of-Life Assessment of Fibroid Treatment Options and Outcomes

    PubMed Central

    Kong, Chung Yin; Tempany, Clare M.; Swan, J. Shannon

    2011-01-01

    Purpose: To obtain utilities (a unit of measure of a person’s relative preferences for different health states compared with death or worst possible outcome) for uterine fibroids before and after treatment and to measure short-term utilities for the following uterine fibroid treatments: abdominal hysterectomy, magnetic resonance (MR) imaging–guided focused ultrasound surgery, and uterine artery embolization (UAE). Materials and Methods: This retrospective study was approved by the institutional review board and was HIPAA compliant. The waiting trade-off (WTO) method, a variation on the time trade-off (TTO) method, is used to obtain utilities for diagnostic procedures on the basis of the fact that people wait longer to avoid noxious tests and/or procedures. The WTO method provides short-term quality of life tolls in terms of quality-adjusted life-weeks by scaling wait times with pre- and posttreatment utilities. Utilities for uterine fibroids before and after treatment were obtained with the TTO method and a visual analog scale (VAS) by using a questionnaire administered by means of a phone interview. WTO wait times were adjusted for quality of life with VAS and TTO utilities and a transformation of VAS. Wait times were compared by using nonparametric tests. The study participants included 62 patients who had undergone abdominal hysterectomy, 74 who had undergone UAE, and 61 who had undergone MR imaging–guided focused ultrasound surgery. Results: Quality of life increased with all treatments. The median WTO wait time was higher for hysterectomy (21.6 weeks) than for UAE or MR imaging–guided focused ultrasound surgery (14.1 weeks for both) (P < .05). Quality-adjusted life-week tolls were smaller when scaled according to TTO than when scaled according to VAS or transformation of VAS. Conclusion: Quality of life increased after all fibroid treatments. WTO is feasible for assessing the quality-adjusted morbidity of treatment procedures. © RSNA, 2011

  10. Do social relations buffer the effect of neighborhood deprivation on health-related quality of life? Results from the LifeLines Cohort Study.

    PubMed

    Klijs, Bart; Mendes de Leon, Carlos F; Kibele, Eva U B; Smidt, Nynke

    2017-03-01

    We investigated whether social relations buffer the effect of neighborhood deprivation on mental and physical health-related quality of life. Baseline data from the LifeLines Cohort Study (N=68,111) and a neighborhood deprivation index were used to perform mixed effect linear regression analyses. Results showed that fewer personal contacts (b, 95%CI: -0.88(-1.08;-0.67)) and lower social need fulfillment (-4.52(-4.67;-4.36)) are associated with lower mental health-related quality of life. Higher neighborhood deprivation was also associated with lower mental health related quality of life (-0.18(-0.24;-0.11)), but only for those with few personal contacts or low social need fulfillment. Our results suggest that social relations buffer the effect of neighborhood deprivation on mental health-related quality of life. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. Techniques for obtaining subjective response to vertical vibration

    NASA Technical Reports Server (NTRS)

    Clarke, M. J.; Oborne, D. J.

    1975-01-01

    Laboratory experiments were performed to validate the techniques used for obtaining ratings in the field surveys carried out by the University College of Swansea. In addition, attempts were made to evaluate the basic form of the human response to vibration. Some of the results obtained by different methods are described.

  12. Evaluation of diet quality of the elderly and associated factors.

    PubMed

    Pinto de Souza Fernandes, Dalila; Duarte, Maria Sônia Lopes; Pessoa, Milene Cristine; Franceschini, Sylvia do Carmo Castro; Ribeiro, Andréia Queiroz

    2017-09-01

    Observational studies suggest healthy dietary patterns are associated with risk reduction and better control of various chronic diseases. However, few Brazilian studies have focused on evaluating the quality of the elderly diet and its relationship with diseases. This study aimed to estimate the association between diet quality and socioeconomic factors, health and nutrition of the elderly. This is a cross-sectional population-based study whose target population were non-institutionalized elderly residents in the city of Viçosa, Brazil. Anthropometric, socioeconomic, health conditions, lifestyle and food consumption variables were obtained from a semi-structured questionnaire. The quality of the diet was assessed by the revised Healthy Eating Index classified into tertiles, considering the first tertile as "Poor diet quality," the second as 'Intermediate diet quality' and the third as "Better diet quality." To identify factors independently associated with diet quality model, the works used multinomial logistic regression. In the results of the multivariate analysis, the factors independently associated with "better diet quality" included female gender, higher education, history of one to five medical visits in the past year, history of diabetes mellitus, dyslipidemia and the use of polypharmacy. Our results show that most seniors need to improve the quality of their diet and those of male gender with no or little education, and those who do not seek medical services constitute the group that needs attention concerning the measures to improve the quality of their diet. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Information system of quality assessment for liquid and gaseous medium production

    NASA Astrophysics Data System (ADS)

    Bobrov, V. N.; Us, N. A.; Davidov, I. S.

    2018-05-01

    A method and a technical solution for controlling the quality of production of liquid and gaseous media is proposed. It is also proposed to monitor harmful factors in production while ensuring safe working conditions. Initially, using the mathematical model of an ideal atmosphere, the projection to the horizontal surface of the observation trajectory is calculated. At the second stage, the horizontal projection of the observation trajectory in real conditions is measured. The quality of the medium is judged by the difference between the projections of observation trajectories. The technical result is presented in the form of a device allowing obtaining information about the quality of the medium under investigation.

  14. Employment and Quality of Survivorship Among Women With Cancer: Domains Not Captured by Quality of Life Instruments

    PubMed Central

    Frazier, Linda M.; Miller, Virginia A.; Horbelt, Douglas V.; Delmore, James E.; Miller, Brigitte E.; Averett, Ellen P.

    2009-01-01

    Background Many quality of life instruments assess the amount of paid work in combination with role function at home in the same items and do not specifically assess social support in the workplace. The goal of this study was to obtain women’s views on the relationship between employment and health-related quality of life. Methods A focus group and questionnaire study was conducted among 73 women with gynecologic cancer who were employed at diagnosis and 25 people who provided them with psychosocial support. Results The women held a variety of blue collar and white collar jobs at diagnosis. Employment provided a strong sense of accomplishment and a welcome distraction during treatment. The employment experience was described as distinct from role function at home. No one equated working more hours with better quality of life. Social support at work could be poor at the same time that support from family and friends grew stronger. Conclusions The contribution to their quality of life that cancer survivors feel they receive from employment may not be linearly related to the quantity of their role function in the workplace. Employment-related items could be useful as an adjunct to standard quality of life measures. PMID:19078931

  15. Understanding the direction of the relationship between white matter hyperintensities of vascular origin, sleep quality, and chronic kidney disease-Results from the Atahualpa Project.

    PubMed

    Del Brutto, Oscar H; Mera, Robertino M

    2018-02-01

    The burden of cerebral small vessel disease, sleep disorders, and chronic kidney disease is on the rise in remote rural settings. However, information on potential links between these conditions is limited. We aimed to assess the relationships between these conditions in community-dwelling older adults living in rural Ecuador. Atahualpa residents aged ≥60 years were offered a brain MRI. A venous blood sample was obtained for serum creatinine determination. Baseline interviews and procedures were directed to assess demographics, cardiovascular risk factors, and sleep quality. Using generalized structural equation modeling (GSEM), we assessed the associations between white matter hyperintensities (WMH) of vascular origin, sleep quality and kidney function, as well as the directions of the relationships between these variables. Of 423 candidates, 314 (74%) were enrolled. Moderate-to-severe WMH were noticed in 74 (24%) individuals, poor sleep quality in 101 (31%), and moderate-to-severe chronic kidney disease in 28 (9%). GSEM showed that the direction of the effect was from kidney function to WMH and from the latter to sleep quality. Of independent variables investigated, worse kidney function was associated with age, high glucose levels and male sex. WMH was associated with cholesterol blood levels, blood pressure, level of education and severe edentulism. Poor sleep quality was associated with poor physical activity. This population based study shows that chronic kidney disease is associated with increased severity of WMH, which, in turn, is associated with a poor sleep quality. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Audit system on Quality of breast cancer diagnosis and Treatment (QT): results of quality indicators on screen-detected lesions in Italy, 2011-2012.

    PubMed

    Ponti, Antonio; Mano, Maria Piera; Tomatis, Mariano; Baiocchi, Diego; Barca, Alessandra; Berti, Rosa; Casella, Denise; D'Ambrosio, Enrico; Delos, Erika; Donati, Giovanni; Falcini, Fabio; Frammartino, Brunella; Frigerio, Alfonso; Giudici, Fabiola; Mantellini, Paola; Naldoni, Carlo; Olla Atzeni, Carlo; Orzalesi, Lorenzo; Pagano, Giovanni; Pietribiasi, Francesca; Pitarella, Sabina; Ravaioli, Alessandra; Silvestri, Anna; Taffurelli, Mario; Tidone, Enrica; Zanconati, Fabrizio; Segnan, Nereo

    2015-01-01

    This annual survey, conducted by the Italian group for mammography screening (GISMa), collects individual data on diagnosis and treatment of about 50% of screen-detected, operated lesions in Italy. The 2011-2012 results show good overall quality and an improving trend over time. A number of critical issues have been identified, including waiting times (which have had a worsening trend over the years) and compliance with the recommendation of not performing frozen section examination on small lesions. Pre-operative diagnosis improved constantly over time, but there is still a large variation between Regions and programmes. For almost 90% of screen-detected invasive cancers a sentinel lymph node (SLN) biopsy was performed on the axilla, avoiding a large number of potentially harmful dissections. On the other hand, potential overuse of SLN dissection for ductal carcinoma in situ, although apparently starting to decline, deserves further investigation. The detailed results have been distributed, among other ways by means of a web-based data-warehouse, to regional and local screening programmes, in order to allow multidisciplinary discussion and identification of the appropriate solutions to any issues documented by the data. The problem of waiting times should be assigned priority. Specialist Breast Units with adequate case volume and enough resources would provide the best setting for making monitoring effective in producing quality improvements with shorter waiting times.

  17. Quality indicators and their regular use in clinical practice: results from a survey among users of two cardiovascular National Registries in Sweden.

    PubMed

    Algurén, Beatrix; Andersson-Gäre, Boel; Thor, Johan; Andersson, Ann-Christine

    2018-05-14

    To examine the regular use of quality indicators from Swedish cardiovascular National Quality Registries (NQRs) by clinical staff; particularly differences in use between the two NQRs and between nurses and physicians. Cross-sectional online survey study. Two Swedish cardiovascular NQRs: (a) Swedish Heart Failure Registry and (b) Swedeheart. Clinicians (n =185; 70% nurses, 26% physicians) via the NQRs' email networks. Frequency of NQR use for (a) producing healthcare activity statistics; (b) comparing results between similar departments; (c) sharing results with colleagues; (d) identifying areas for quality improvement (QI); (e) surveilling the impact of QI efforts; (f) monitoring effects of implementation of new treatment methods; (g) doing research and (h) educating and informing healthcare professionals and patients. Median use of NQRs was 10 times a year (25th and 75th percentiles range: 3-23 times/year). Quality indicators from the NQRs were used mainly for producing healthcare activity statistics. Median use of Swedeheart was six times greater than Swedish Heart Failure Registry (SwedeHF; P < 0.000). Physicians used the NQRs more than twice as often as nurses (18 vs. 7.5 times/year; P < 0.000) and perceived NQR work more often as meaningful. Around twice as many Swedeheart users had the role to participate in data analysis and in QI efforts compared to SwedeHF users. Most respondents used quality indicators from the two cardiovascular NQRs infrequently (<3 times/year). The results indicate that linking registration of quality indicators to using them for QI activities increases their routine use and makes them meaningful tools for professionals.

  18. A Closed-Loop Supply Chain under Retail Price and Quality Dependent Demand with Remanufacturing and Refurbishing

    NASA Astrophysics Data System (ADS)

    Christy, A. Y.; Fauzi, B. N.; Kurdi, N. A.; Jauhari, W. A.; Saputro, D. R. S.

    2017-06-01

    The demand of a product is linearly dependent on the retail price and quality of the product. We address a closed-loop supply chain where the manufacturer manufactures products according to the demand and sells them through a retailer in the market. A third party collects the used products from costumers and sends to the manufacturer to increase the quality. If the products can retrieve the original quality, thus the process is called remanufacturing. Not every products can retrieve the original quality, thus manufacturer refurbish this products with lower price. We construct four different scenarios - centralized and decentralized led by manufacturer, retailer, and third party. From the comparison of the result obtained in the numerical example, we conclude that the joint profit obtained under centralized, manufacturer-led, and retailer-led policies is higher than third party-led policy.

  19. Quality improving techniques for free-viewpoint DIBR

    NASA Astrophysics Data System (ADS)

    Do, Luat; Zinger, Sveta; de With, Peter H. N.

    2010-02-01

    Interactive free-viewpoint selection applied to a 3D multi-view signal is a possible attractive feature of the rapidly developing 3D TV media. This paper explores a new rendering algorithm that computes a free-viewpoint based on depth image warping between two reference views from existing cameras. We have developed three quality enhancing techniques that specifically aim at solving the major artifacts. First, resampling artifacts are filled in by a combination of median filtering and inverse warping. Second, contour artifacts are processed while omitting warping of edges at high discontinuities. Third, we employ a depth signal for more accurate disocclusion inpainting. We obtain an average PSNR gain of 3 dB and 4.5 dB for the 'Breakdancers' and 'Ballet' sequences, respectively, compared to recently published results. While experimenting with synthetic data, we observe that the rendering quality is highly dependent on the complexity of the scene. Moreover, experiments are performed using compressed video from surrounding cameras. The overall system quality is dominated by the rendering quality and not by coding.

  20. [Quality of service provided to heart surgery patients of the Unified Health System-SUS].

    PubMed

    Borges, Juliana Bassalobre Carvalho; Carvalho, Sebastião Marcos Ribeiro de; Silva, Marcos Augusto de Moraes

    2010-01-01

    To evaluate the service quality provided to heart surgery patients during their hospital stay, identifying the patient's expectations and perceptions. To associate service quality with: gender, age and the use of extracorporeal circulation. We studied 82 elective heart surgery patients (52.4% females and 47.6% males), operated by midsternal thoracotomy, age: 31 to 83 years (60.4 +/- 13.2 years); period: March to September 2006. Service quality was evaluated in two instances: the expectations at pre-operative and the perceptions of the service received on the 6th post-operative; through the application of the modified SERVQUAL scale (SERVQUAL-Card). The result was obtained by the difference of the sum of the scores on perception minus those of the expectations, and through statistical analysis. The SERVQUAL-Card scale was statistically validated, showing adequate level of internal consistency. We found a higher frequency of myocardial revascularization 55 (67.0%); first heart surgery 72 (87.8%) and the use of ECC 69 (84.1%). We noticed high mean values for expectations and perceptions with significant results (P<0.05). We observed a significant relationship between the quality of service with: gender, in empathy (P= 0.04) and age, in reliability (P = 0.02). There was no significant association between ECC and quality of service. Service quality was satisfactory. The patient demonstrated a high expectation to hospital medical service. Women present a higher perception of quality in empathy and younger people in reliability. The use of ECC is not related to service quality in this sample. The data obtained in this study suggest that the quality of this health service can be monitored through the periodical application of the SERVQUAL scale.

  1. Production of high-quality polydisperse construction mixes for additive 3D technologies.

    NASA Astrophysics Data System (ADS)

    Gerasimov, M. D.; Brazhnik, Yu V.; Gorshkov, P. S.; Latyshev, S. S.

    2018-03-01

    The paper describes a new design of a mixer allowing production of high quality polydisperse powders, used in additive 3D technologies. A new principle of dry powder particle mixing is considered, implementing a possibility of a close-to-ideal distribution of such particles in common space. A mathematical model of the mixer is presented, allowing evaluating quality indicators of the produced mixture. Experimental results are shown and rational values of process parameters of the mixer are obtained.

  2. [Compatibility of different quality control systems].

    PubMed

    Invernizzi, Enrico

    2002-01-01

    Management of the good laboratory practice (GLP) quality system presupposes its linking to a basic recognized and approved quality system, from which it can draw on management procedures common to all quality systems, such as the ISO 9000 set of norms. A quality system organized in this way can also be integrated with other dedicated quality systems, or parts of them, to obtain principles or management procedures for specific topics. The aim of this organization is to set up a reliable, recognized quality system compatible with the principles of GLP and other quality management systems, which provides users with a simplified set of easily accessible management tools and answers. The organization of this quality system is set out in the quality assurance programme, which is actually the document in which the test facility incorporates the GLP principles into its own quality organization.

  3. Water quality modelling of Jadro spring.

    PubMed

    Margeta, J; Fistanic, I

    2004-01-01

    Management of water quality in karst is a specific problem. Water generally moves very fast by infiltration processes but far more by concentrated flows through fissures and openings in karst. This enables the entire surface pollution to be transferred fast and without filtration into groundwater springs. A typical example is the Jadro spring. Changes in water quality at the spring are sudden, but short. Turbidity as a major water quality problem for the karst springs regularly exceeds allowable standards. Former practice in problem solving has been reduced to intensive water disinfection in periods of great turbidity without analyses of disinfection by-products risks for water users. The main prerequisite for water quality control and an optimization of water disinfection is the knowledge of raw water quality and nature of occurrence. The analysis of monitoring data and their functional relationship with hydrological parameters enables establishment of a stochastic model that will help obtain better information on turbidity in different periods of the year. Using the model a great number of average monthly and extreme daily values are generated. By statistical analyses of these data possibility of occurrence of high turbidity in certain months is obtained. This information can be used for designing expert system for water quality management of karst springs. Thus, the time series model becomes a valuable tool in management of drinking water quality of the Jadro spring.

  4. Ground-Water Quality Data in the San Fernando-San Gabriel Study Unit, 2005 - Results from the California GAMA Program

    USGS Publications Warehouse

    Land, Michael; Belitz, Kenneth

    2008-01-01

    Ground-water quality in the approximately 460 square mile San Fernando-San Gabriel study unit (SFSG) was investigated between May and July 2005 as part of the Priority Basin Assessment Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Assessment Project was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The San Fernando-San Gabriel study was designed to provide a spatially unbiased assessment of raw ground-water quality within SFSG, as well as a statistically consistent basis for comparing water quality throughout California. Samples were collected from 52 wells in Los Angeles County. Thirty-five of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study area (grid wells), and seventeen wells were selected to aid in the evaluation of specific water-quality issues or changes in water chemistry along a historic ground-water flow path (understanding wells). The ground-water samples were analyzed for a large number of synthetic organic constituents [volatile organic compounds (VOCs), pesticides and pesticide degradates], constituents of special interest [perchlorate, N-nitrosodimethylamine (NDMA), 1,2,3-trichloropropane (1,2,3-TCP), and 1,4-dioxane], naturally occurring inorganic constituents (nutrients, major and minor ions, and trace elements), radioactive constituents, and microbial indicators. Naturally occurring isotopes (tritium, and carbon-14, and stable isotopes of hydrogen, oxygen, and carbon), and dissolved noble gases also were measured to help identify the source and age of the sampled ground water. Quality-control samples (blanks, replicates, samples for matrix spikes) were collected at approximately one-fifth (11 of 52) of the wells, and the results for these

  5. A Comprehensive Method for GNSS Data Quality Determination to Improve Ionospheric Data Analysis

    PubMed Central

    Kim, Minchan; Seo, Jiwon; Lee, Jiyun

    2014-01-01

    Global Navigation Satellite Systems (GNSS) are now recognized as cost-effective tools for ionospheric studies by providing the global coverage through worldwide networks of GNSS stations. While GNSS networks continue to expand to improve the observability of the ionosphere, the amount of poor quality GNSS observation data is also increasing and the use of poor-quality GNSS data degrades the accuracy of ionospheric measurements. This paper develops a comprehensive method to determine the quality of GNSS observations for the purpose of ionospheric studies. The algorithms are designed especially to compute key GNSS data quality parameters which affect the quality of ionospheric product. The quality of data collected from the Continuously Operating Reference Stations (CORS) network in the conterminous United States (CONUS) is analyzed. The resulting quality varies widely, depending on each station and the data quality of individual stations persists for an extended time period. When compared to conventional methods, the quality parameters obtained from the proposed method have a stronger correlation with the quality of ionospheric data. The results suggest that a set of data quality parameters when used in combination can effectively select stations with high-quality GNSS data and improve the performance of ionospheric data analysis. PMID:25196005

  6. Lichen bioindication of biodiversity, air quality, and climate: baseline results from monitoring in Washington, Oregon, and California.

    Treesearch

    Sarah Jovan

    2008-01-01

    Lichens are highly valued ecological indicators known for their sensitivity to a wide variety of environmental stressors like air quality and climate change. This report summarizes baseline results from the U.S. Department of Agriculture, Forest Service, Forest Inventory and Analysis (FIA) Lichen Community Indicator covering the first full cycle of data collection (...

  7. Preliminary results on complex ceramic layers deposition by atmospheric plasma spraying

    NASA Astrophysics Data System (ADS)

    Florea, Costel; Bejinariu, Costicǎ; Munteanu, Corneliu; Cimpoeşu, Nicanor

    2017-04-01

    In this article we obtain thin layers from complex ceramic powders using industrial equipment based on atmospheric plasma spraying. We analyze the influence of the substrate material roughness on the quality of the thin layers using scanning electron microscopy (SEM) and X-ray dispersive energy analyze (EDAX). Preliminary results present an important dependence between the surface state and the structural and chemical homogeneity.

  8. Ground-Water Quality Data in the Santa Clara River Valley Study Unit, 2007: Results from the California GAMA Program

    USGS Publications Warehouse

    Montrella, Joseph; Belitz, Kenneth

    2009-01-01

    and age of the sampled ground water. Quality-control samples (blanks or replicates, or samples for matrix spikes) were collected from approximately 26 percent of the wells, and the analyses of these samples were used to evaluate the quality of the data for the ground-water samples. Assessment of the quality-control results showed that the quality of the environmental data was good, with low bias and low variability, and as a result, less than 0.1 percent of the analytes detected in ground-water samples were censored. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, and (or) blended with other waters to maintain acceptable water quality. Regulatory thresholds apply to treated water that is delivered (or, supplied) to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with regulatory and non-regulatory thresholds established by the U.S. Environmental Protection Agency (USEPA) and the California Department of Public Health (CDPH) and thresholds established for aesthetic concerns (secondary maximum contaminant levels, SMCL-CA) by CDPH. Most constituents that were detected in ground-water samples were reported at concentrations below their established health-based thresholds. VOCs, pesticides and pesticide degradates, and potential wastewater-indicator compounds were detected in about 33 percent or less of the 42 SCRV grid wells. Concentrations of all detected organic constituents were below established health-based thresholds. Perchlorate was detected in approximately 12 percent of the SCRV grid wells; all concentrations reported were below the NL-CA threshold. Additional constituents, including major ions, trace elements, and nutrients were collected at 26 wells (16 grid wells and 10 understanding wells) of the 53 wells sampled f

  9. Ground-Water Quality Data in the Coastal Los Angeles Basin Study Unit, 2006: Results from the California GAMA Program

    USGS Publications Warehouse

    Mathany, Timothy M.; Land, Michael; Belitz, Kenneth

    2008-01-01

    ] and dissolved noble gases also were measured to help identify the sources and ages of the sampled ground water. Quality-control samples (blanks, replicates, and samples for matrix spikes) were collected at approximately one-fourth of the wells, and the results for these samples were used to evaluate the quality of the data for the ground-water samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a significant source of bias. Differences between replicate samples were within acceptable ranges, indicating acceptably low variability. Matrix spike recoveries were within acceptable ranges for most compounds. Assessment of the quality-control information resulted in applying ?V? codes to approximately 0.1 percent of the data collected for ground-water samples (meaning a constituent was detected in blanks as well as the corresponding environmental data). This study did not attempt to evaluate the quality of drinking water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, and (or) blended with other waters to maintain acceptable drinking-water quality. Regulatory thresholds are applied to the treated drinking water that is served to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with regulatory and non-regulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA), California Department of Public Health (CDPH, formerly California Department of Health Services [CADHS]) and thresholds established for aesthetic concerns (secondary maximum contaminant levels, SMCL-CA) by CDPH. Comparisons between data collected for this study and drinking-water thresholds are for illustrative purposes only, and are not indicative of compliance or non-compliance with those thresholds. VOCs were detected in alm

  10. A feasibility study of prepubertal and over mature aged local goat in relation to results of In Vitro growth culture to obtain additional M-II oocyte resources

    NASA Astrophysics Data System (ADS)

    Ciptadi, Gatot; Ihsan, M. Nur; Rahayu, Sri; Widjaja, D. H. K.; Mudawamah, Mudawamah

    2017-11-01

    The aims of this research are to study the potential source of mature (M-II) oocytes of domestic animals using follicles isolated from prepubertal and over mature aged Indonesian local goats, resulting from an in vitro growth (IVG) method. This method of IVG could provide a new source of M-II oocytes for embryo production. In Indonesia, a very limited number of a good quality oocytes are available for research purposes, as there is a limited number of reproductive females slaughtered, which is dominated by prepubertal and old mature aged animals. IVG culture systems could be improved as an alternative method to provide a new source of a good quality oocytes for in vitro maturation of M-II oocytes. From a number of prepubertal and mature aged goats slaughtered in a local abattoir, the small oocytes in the preantral follicles were cultured in vitro to normal oocyte growth. The methods used in this research are experimental. Follicles were isolated, cultured in vitro for 14 days individually using a sticky medium containing 4% (w/v) polyvinylpyrrolidone in TCM 199 10% Fetal Bovine Serum supplemented with Follicle Stimulating Hormone, which was then evaluated for their follicle development and oocyte quality. The research results showed that a minimum follicle size and oocyte diameter is needed (>100 um) for early evaluation of maturation to be achieved, meanwhile oocytes recovered from IVG after being cultured in vitro for maturation resulted in a very low rate of maturation. However, in the future, IVG of the preantral follicles of Indonesian local goat could be considered as an alternative source of oocytes for both research purposes and embryo production in vitro.

  11. A Quality Process Approach to Electronic System Reliability: Supplier Quality Assessment Procedure. Volume 2

    DTIC Science & Technology

    1993-11-01

    AND SUPPORT SERVICE QUALITY ....... 16 3.5.7 SUPPLIER QUALITY ............................................................................. 16 3.6...RESULTS ......................................................................................................... 16 3.6.1 PRODUCT AND SERVICE QUALITY RESULTS...10 5.6 Business Process and Support Service Quality 20 5.7 Supplier Quality 20 6.0 Results 180 6.1 Product and Service Quality Results 90 6.2 Business

  12. Improving Forecast Skill by Assimilation of Quality Controlled AIRS Version 5 Temperature Soundings

    NASA Technical Reports Server (NTRS)

    Susskind, Joel; Reale, Oreste

    2009-01-01

    The AIRS Science Team Version 5 retrieval algorithm has been finalized and is now operational at the Goddard DAAC in the processing (and reprocessing) of all AIRS data. The AIRS Science Team Version 5 retrieval algorithm contains two significant improvements over Version 4: 1) Improved physics allows for use of AIRS observations in the entire 4.3 micron CO2 absorption band in the retrieval of temperature profile T(p) during both day and night. Tropospheric sounding 15 micron CO2 observations are now used primarily in the generation of cloud cleared radiances R(sub i). This approach allows for the generation of accurate values of R(sub i) and T(p) under most cloud conditions. 2) Another very significant improvement in Version 5 is the ability to generate accurate case-by-case, level-by-level error estimates for the atmospheric temperature profile, as well as for channel-by-channel error estimates for R(sub i). These error estimates are used for Quality Control of the retrieved products. We have conducted forecast impact experiments assimilating AIRS temperature profiles with different levels of Quality Control using the NASA GEOS-5 data assimilation system. Assimilation of Quality Controlled T(p) resulted in significantly improved forecast skill compared to that obtained from analyses obtained when all data used operationally by NCEP, except for AIRS data, is assimilated. We also conducted an experiment assimilating AIRS radiances uncontaminated by clouds, as done operationally by ECMWF and NCEP. Forecast resulting from assimilated AIRS radiances were of poorer quality than those obtained assimilating AIRS temperatures.

  13. Study of Image Quality From CT Scanner Multi-Detector by using Americans College of Radiology (ACR) Phantom

    NASA Astrophysics Data System (ADS)

    Mulyadin; Dewang, Syamsir; Abdullah, Bualkar; Tahir, Dahlang

    2018-03-01

    In this study, the image quality of CT scan using phantom American College of Radiology (ACR) was determined. Scanning multidetector CT is used to know the image quality parameters by using a solid phantom containing four modules and primarily from materials that are equivalent to water. Each module is 4 cm in diameter and 20 cm in diameter. There is white alignment marks painted white to reflect the alignment laser and there are also “HEAD”, “FOOT”, and “TOP” marks on the phantom to help align. This test obtains CT images of each module according to the routine inspection protocol of the head. Acceptance of image quality obtained for determination: CT Number Accuracy (CTN), CT Number Uniformity and Noise, Linearity CT Number, Slice Technique, Low Contrast Resolution and High Contrast Resolution represent image quality parameters. In testing CT Number Accuracy (CTN), CT Uniform number and Noise are in the range of tolerable values allowed. In the test, Linearity CT Number obtained correlation value above 0.99 is the relationship between electron density and CT Number. In a low contrast resolution test, the smallest contrast groups are visible. In contrast, the high resolution is seen up to 7 lp/cm. The quality of GE CT Scan is very high, as all the image quality tests obtained are within the tolerance brackets of values permitted by the Nuclear Power Control Agency (BAPETEN). Image quality test is a way to get very important information about the accuracy of snoring result by using phantom ACR.

  14. Groundwater-quality data for the Sierra Nevada study unit, 2008: Results from the California GAMA program

    USGS Publications Warehouse

    Shelton, Jennifer L.; Fram, Miranda S.; Munday, Cathy M.; Belitz, Kenneth

    2010-01-01

    Nevada study unit: granitic, metamorphic, sedimentary, and volcanic rocks. One natural spring that is not used for drinking water was sampled for comparison with a nearby primary grid well in the same cell. Groundwater samples were analyzed for organic constituents (volatile organic compounds [VOC], pesticides and pesticide degradates, and pharmaceutical compounds), constituents of special interest (N-nitrosodimethylamine [NDMA] and perchlorate), naturally occurring inorganic constituents (nutrients, major ions, total dissolved solids, and trace elements), and radioactive constituents (radium isotopes, radon-222, gross alpha and gross beta particle activities, and uranium isotopes). Naturally occurring isotopes and geochemical tracers (stable isotopes of hydrogen and oxygen in water, stable isotopes of carbon, carbon-14, strontium isotopes, and tritium), and dissolved noble gases also were measured to help identify the sources and ages of the sampled groundwater. Three types of quality-control samples (blanks, replicates, and samples for matrix spikes) each were collected at approximately 10 percent of the wells sampled for each analysis, and the results for these samples were used to evaluate the quality of the data for the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination from sample collection, handling, and analytical procedures was not a significant source of bias in the data for the groundwater samples. Differences between replicate samples were within acceptable ranges, with few exceptions. Matrix-spike recoveries were within acceptable ranges for most compounds. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, groundwater typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory benchmarks apply to finished drinking water that is served to the consumer, not to untre

  15. Quality Assessment of Studies Published in Open Access and Subscription Journals: Results of a Systematic Evaluation.

    PubMed

    Pastorino, Roberta; Milovanovic, Sonja; Stojanovic, Jovana; Efremov, Ljupcho; Amore, Rosarita; Boccia, Stefania

    2016-01-01

    Along with the proliferation of Open Access (OA) publishing, the interest for comparing the scientific quality of studies published in OA journals versus subscription journals has also increased. With our study we aimed to compare the methodological quality and the quality of reporting of primary epidemiological studies and systematic reviews and meta-analyses published in OA and non-OA journals. In order to identify the studies to appraise, we listed all OA and non-OA journals which published in 2013 at least one primary epidemiologic study (case-control or cohort study design), and at least one systematic review or meta-analysis in the field of oncology. For the appraisal, we picked up the first studies published in 2013 with case-control or cohort study design from OA journals (Group A; n = 12), and in the same time period from non-OA journals (Group B; n = 26); the first systematic reviews and meta-analyses published in 2013 from OA journals (Group C; n = 15), and in the same time period from non-OA journals (Group D; n = 32). We evaluated the methodological quality of studies by assessing the compliance of case-control and cohort studies to Newcastle and Ottawa Scale (NOS) scale, and the compliance of systematic reviews and meta-analyses to Assessment of Multiple Systematic Reviews (AMSTAR) scale. The quality of reporting was assessed considering the adherence of case-control and cohort studies to STrengthening the Reporting of OBservational studies in Epidemiology (STROBE) checklist, and the adherence of systematic reviews and meta-analyses to Preferred Reporting Items for Systematic reviews and Meta-Analysis (PRISMA) checklist. Among case-control and cohort studies published in OA and non-OA journals, we did not observe significant differences in the median value of NOS score (Group A: 7 (IQR 7-8) versus Group B: 8 (7-9); p = 0.5) and in the adherence to STROBE checklist (Group A, 75% versus Group B, 80%; p = 0.1). The results did not change after adjustment

  16. Packaging and labeling of pharmaceutical products obtained from the internet.

    PubMed

    Veronin, Michael

    2011-02-15

    For patients, the prescription container label may be the only source of instructions on how to take their medicines. In the United States, the legal requirements for a prescription label are set by federal law and state statutes. The container should be comparable to that which manufacturers use to package drug products and should preserve a product's identity, strength, quality, and purity and prevent contamination. Safety features such as a child-resistant closure should be provided. Pharmaceutical products purchased from international online pharmacies are not approved by the Food and Drug Administration (FDA) and may not meet US guidelines for labeling and packaging. The study objective was to determine whether commonly purchased pharmaceutical products obtained from international online pharmacies are comparable to products dispensed in the United States with regard to labeling and packaging. During March 2006 through January 2007, 41 pharmaceutical oral dosage form samples were obtained from international Internet pharmacy websites for evaluation: 18 generic simvastatin samples, 18 generic amlodipine samples, and 5 generic sildenafil samples. Contents for each package were observed and recorded and comparison of the prescription labeling and packaging of these products was made with prescription labeling and packaging requirements in the United States. Of the 41 drug products obtained from online pharmacies from 12 different countries, only 1 product (from Canada) would meet both labeling and packaging guidelines for products dispensed in the United States. Of those not meeting the requirements, 7 were dispensed in paper envelopes with label affixed that was either handwritten or typed and contained missing information such as name and address of dispenser, name of prescriber, name of patient, and directions for use. Another 3 products did not have a label affixed to the drug product, but information was printed on a paper document enclosed in the shipping

  17. Quality standards for predialysis education: results from a consensus conference.

    PubMed

    Isnard Bagnis, Corinne; Crepaldi, Carlo; Dean, Jessica; Goovaerts, Tony; Melander, Stefan; Nilsson, Eva-Lena; Prieto-Velasco, Mario; Trujillo, Carmen; Zambon, Roberto; Mooney, Andrew

    2015-07-01

    This position statement was compiled following an expert meeting in March 2013, Zurich, Switzerland. Attendees were invited from a spread of European renal units with established and respected renal replacement therapy option education programmes. Discussions centred around optimal ways of creating an education team, setting realistic and meaningful objectives for patient education, and assessing the quality of education delivered. © The Author 2014. Published by Oxford University Press on behalf of ERA-EDTA.

  18. Identifying a Comparison for Matching Rough Voice Quality

    ERIC Educational Resources Information Center

    Patel, Sona; Shrivastav, Rahul; Eddins, David A.

    2012-01-01

    Purpose: Perceptual estimates of voice quality obtained using rating scales are subject to contextual biases that influence how individuals assign numbers to estimate the magnitude of vocal quality. Because rating scales are commonly used in clinical settings, assessments of voice quality are also subject to the limitations of these scales.…

  19. Optimal spatio-temporal design of water quality monitoring networks for reservoirs: Application of the concept of value of information

    NASA Astrophysics Data System (ADS)

    Maymandi, Nahal; Kerachian, Reza; Nikoo, Mohammad Reza

    2018-03-01

    This paper presents a new methodology for optimizing Water Quality Monitoring (WQM) networks of reservoirs and lakes using the concept of the value of information (VOI) and utilizing results of a calibrated numerical water quality simulation model. With reference to the value of information theory, water quality of every checkpoint with a specific prior probability differs in time. After analyzing water quality samples taken from potential monitoring points, the posterior probabilities are updated using the Baye's theorem, and VOI of the samples is calculated. In the next step, the stations with maximum VOI is selected as optimal stations. This process is repeated for each sampling interval to obtain optimal monitoring network locations for each interval. The results of the proposed VOI-based methodology is compared with those obtained using an entropy theoretic approach. As the results of the two methodologies would be partially different, in the next step, the results are combined using a weighting method. Finally, the optimal sampling interval and location of WQM stations are chosen using the Evidential Reasoning (ER) decision making method. The efficiency and applicability of the methodology are evaluated using available water quantity and quality data of the Karkheh Reservoir in the southwestern part of Iran.

  20. Italian external quality assessment program for cystic fibrosis sweat chloride test: a 2015 and 2016 results comparison.

    PubMed

    Salvatore, Marco; Floridia, Giovanna; Amato, Annalisa; Censi, Federica; de Stefano, Maria Chiara; Ferrari, Gianluca; Tosto, Fabrizio; Taruscio, Domenica

    2017-01-01

    Diagnostic testing in cystic fibrosis (CF) is based on the sweat chloride test (SCT) in the context of appropriate signs and symptoms of disease and results of the gene mutation analysis. In 2014 the Istituto Superiore di Sanità (ISS) established a pilot Italian external quality assessment program for CF sweat chloride test (Italian EQA-SCT). In 2015 this activity was recognized as a third party service carried out by the ISS. The aim of the paper is to compare 2015 and 2016 results and experiences. The scheme is prospective; enrollment is voluntary and the payment of a fee is required. Participants are registered and identified by a specific Identification Number (ID) through a dedicated web-facility. Assessment covers analysis, interpretation and reporting of results. Thirteen and fifteen laboratories, participated in the 2015 and 2016 round respectively. Seven laboratories participated constantly from 2014, eleven participated both in 2015 and 2016 and four participated in 2016 for the first time. Variability in scores of chloride titration and heterogeneity in interpretation/reporting results were detected in both rounds. A total of 18 critical errors in chloride titration were made by eight different participants. Four laboratories made errors in chloride titration in 2015 but drastically improved their performance in 2016. In 2016 poor performance criteria were established and adopted. Even though results show variability in performance of laboratories, constant and mandatory participation may contribute to the improvement of performance and quality reached by laboratory.