Sample records for quantitative 4d transcatheter

  1. Quantitative 4D Transcatheter Intraarterial Perfusion MR Imaging as a Method to Standardize Angiographic Chemoembolization Endpoints

    PubMed Central

    Jin, Brian; Wang, Dingxin; Lewandowski, Robert J.; Ryu, Robert K.; Sato, Kent T.; Larson, Andrew C.; Salem, Riad; Omary, Reed A.

    2011-01-01

    PURPOSE We aimed to test the hypothesis that subjective angiographic endpoints during transarterial chemoembolization (TACE) of hepatocellular carcinoma (HCC) exhibit consistency and correlate with objective intraprocedural reductions in tumor perfusion as determined by quantitative four dimensional (4D) transcatheter intraarterial perfusion (TRIP) magnetic resonance (MR) imaging. MATERIALS AND METHODS This prospective study was approved by the institutional review board. Eighteen consecutive patients underwent TACE in a combined MR/interventional radiology (MR-IR) suite. Three board-certified interventional radiologists independently graded the angiographic endpoint of each procedure based on a previously described subjective angiographic chemoembolization endpoint (SACE) scale. A consensus SACE rating was established for each patient. Patients underwent quantitative 4D TRIP-MR imaging immediately before and after TACE, from which mean whole tumor perfusion (Fρ) was calculated. Consistency of SACE ratings between observers was evaluated using the intraclass correlation coefficient (ICC). The relationship between SACE ratings and intraprocedural TRIP-MR imaging perfusion changes was evaluated using Spearman’s rank correlation coefficient. RESULTS The SACE rating scale demonstrated very good consistency among all observers (ICC = 0.80). The consensus SACE rating was significantly correlated with both absolute (r = 0.54, P = 0.022) and percent (r = 0.85, P < 0.001) intraprocedural perfusion reduction. CONCLUSION The SACE rating scale demonstrates very good consistency between raters, and significantly correlates with objectively measured intraprocedural perfusion reductions during TACE. These results support the use of the SACE scale as a standardized alternative method to quantitative 4D TRIP-MR imaging to classify patients based on embolic endpoints of TACE. PMID:22021520

  2. Quantitative Prediction of Paravalvular Leak in Transcatheter Aortic Valve Replacement Based on Tissue-Mimicking 3D Printing.

    PubMed

    Qian, Zhen; Wang, Kan; Liu, Shizhen; Zhou, Xiao; Rajagopal, Vivek; Meduri, Christopher; Kauten, James R; Chang, Yung-Hang; Wu, Changsheng; Zhang, Chuck; Wang, Ben; Vannan, Mani A

    2017-07-01

    This study aimed to develop a procedure simulation platform for in vitro transcatheter aortic valve replacement (TAVR) using patient-specific 3-dimensional (3D) printed tissue-mimicking phantoms. We investigated the feasibility of using these 3D printed phantoms to quantitatively predict the occurrence, severity, and location of any degree of post-TAVR paravalvular leaks (PVL). We have previously shown that metamaterial 3D printing technique can be used to create patient-specific phantoms that mimic the mechanical properties of biological tissue. This may have applications in procedural planning for cardiovascular interventions. This retrospective study looked at 18 patients who underwent TAVR. Patient-specific aortic root phantoms were created using the tissue-mimicking 3D printing technique using pre-TAVR computed tomography. The CoreValve (self-expanding valve) prostheses were deployed in the phantoms to simulate the TAVR procedure, from which post-TAVR aortic root strain was quantified in vitro. A novel index, the annular bulge index, was measured to assess the post-TAVR annular strain unevenness in the phantoms. We tested the comparative predictive value of the bulge index and other known predictors of post-TAVR PVL. The maximum annular bulge index was significantly different among patient subgroups that had no PVL, trace-to-mild PVL, and moderate-to-severe PVL (p = 0.001). Compared with other known PVL predictors, bulge index was the only significant predictor of moderate-severe PVL (area under the curve = 95%; p < 0.0001). Also, in 12 patients with post-TAVR PVL, the annular bulge index predicted the major PVL location in 9 patients (accuracy = 75%). In this proof-of-concept study, we have demonstrated the feasibility of using 3D printed tissue-mimicking phantoms to quantitatively assess the post-TAVR aortic root strain in vitro. A novel indicator of the post-TAVR annular strain unevenness, the annular bulge index, outperformed the other

  3. Computer Vision Techniques for Transcatheter Intervention

    PubMed Central

    Zhao, Feng; Roach, Matthew

    2015-01-01

    Minimally invasive transcatheter technologies have demonstrated substantial promise for the diagnosis and the treatment of cardiovascular diseases. For example, transcatheter aortic valve implantation is an alternative to aortic valve replacement for the treatment of severe aortic stenosis, and transcatheter atrial fibrillation ablation is widely used for the treatment and the cure of atrial fibrillation. In addition, catheter-based intravascular ultrasound and optical coherence tomography imaging of coronary arteries provides important information about the coronary lumen, wall, and plaque characteristics. Qualitative and quantitative analysis of these cross-sectional image data will be beneficial to the evaluation and the treatment of coronary artery diseases such as atherosclerosis. In all the phases (preoperative, intraoperative, and postoperative) during the transcatheter intervention procedure, computer vision techniques (e.g., image segmentation and motion tracking) have been largely applied in the field to accomplish tasks like annulus measurement, valve selection, catheter placement control, and vessel centerline extraction. This provides beneficial guidance for the clinicians in surgical planning, disease diagnosis, and treatment assessment. In this paper, we present a systematical review on these state-of-the-art methods. We aim to give a comprehensive overview for researchers in the area of computer vision on the subject of transcatheter intervention. Research in medical computing is multi-disciplinary due to its nature, and hence, it is important to understand the application domain, clinical background, and imaging modality, so that methods and quantitative measurements derived from analyzing the imaging data are appropriate and meaningful. We thus provide an overview on the background information of the transcatheter intervention procedures, as well as a review of the computer vision techniques and methodologies applied in this area. PMID:27170893

  4. A Retrospective Study of 1,526 Cases of Transcatheter Occlusion of Patent Ductus Arteriosus.

    PubMed

    Jin, Mei; Liang, Yong-Mei; Wang, Xiao-Fang; Guo, Bao-Jing; Zheng, Ke; Gu, Yan; Lyu, Zhen-Yu

    2015-09-05

    Patent ductus arteriosus (PDA) is one of the most common congenital heart diseases and began to get treated by transcatheter occlusion since 1997 in China. Since then, several devices have been invented for occluding PDA. This study aimed to evaluate the technical feasibility, safety, and efficacy of transcatheter occlusion of PDA with different devices. One thousand five hundred and twenty-six patients (537 boys, 989 girls) with PDA from January 1997 to September 2014 underwent descending aortogram and transcatheter occlusion procedure. We retrospectively analyzed data of these patients, including gender, age, weight, size and morphology of PDA, and devices used in transcatheter occlusion, outcomes, and postoperational complications. Median age and median weight were 4.0 years (range: 0.3-52.0 years old) and 15.3 kg (range: 4.5-91.0 kg), respectively. Mean ductal diameter, aortic ductal diameter, ductal length, and pulmonary artery pressure were 3.50 ± 2.15 mm, 10.08 ± 2.46 mm, 7.49 ± 3.02 mm, and 30.21 ± 17.28 mmHg, respectively. Morphology of PDA assessed by descending aortogram was of type A in 1428 patients, type B in 6 patients, type C in 79 patients, type D in 4 patients, and type E in 9 patients according to the classification of Krichenko. Of all the 1526 patients, 1497 patients underwent transcatheter PDA closure, among which 1492 were successful. Devices used were Amplatzer duct occluder I (ADO I, 1280, 85.8%), Cook detachable coils (116, 7.8%), ADO II (ADO II, 68, 4.6%), muscular VSD occluder (12, 0.8%), and Amplatzer vascular plug (16, 1.0%). Excellent occlusion rates with low complication rates were achieved with all devices regardless of PDA types. With transcatheter occlusion technique and devices developing, more patients with PDA can be treated with transcatheter closure both safely and efficiently.

  5. A Retrospective Study of 1526 Cases of Transcatheter Occlusion of Patent Ductus Arteriosus

    PubMed Central

    Jin, Mei; Liang, Yong-Mei; Wang, Xiao-Fang; Guo, Bao-Jing; Zheng, Ke; Gu, Yan; Lyu, Zhen-Yu

    2015-01-01

    Background: Patent ductus arteriosus (PDA) is one of the most common congenital heart diseases and began to get treated by transcatheter occlusion since 1997 in China. Since then, several devices have been invented for occluding PDA. This study aimed to evaluate the technical feasibility, safety, and efficacy of transcatheter occlusion of PDA with different devices. Methods: One thousand five hundred and twenty-six patients (537 boys, 989 girls) with PDA from January 1997 to September 2014 underwent descending aortogram and transcatheter occlusion procedure. We retrospectively analyzed data of these patients, including gender, age, weight, size and morphology of PDA, and devices used in transcatheter occlusion, outcomes, and postoperational complications. Results: Median age and median weight were 4.0 years (range: 0.3–52.0 years old) and 15.3 kg (range: 4.5–91.0 kg), respectively. Mean ductal diameter, aortic ductal diameter, ductal length, and pulmonary artery pressure were 3.50 ± 2.15 mm, 10.08 ± 2.46 mm, 7.49 ± 3.02 mm, and 30.21 ± 17.28 mmHg, respectively. Morphology of PDA assessed by descending aortogram was of type A in 1428 patients, type B in 6 patients, type C in 79 patients, type D in 4 patients, and type E in 9 patients according to the classification of Krichenko. Of all the 1526 patients, 1497 patients underwent transcatheter PDA closure, among which 1492 were successful. Devices used were Amplatzer duct occluder I (ADO I, 1280, 85.8%), Cook detachable coils (116, 7.8%), ADO II (ADO II, 68, 4.6%), muscular VSD occluder (12, 0.8%), and Amplatzer vascular plug (16, 1.0%). Conclusions: Excellent occlusion rates with low complication rates were achieved with all devices regardless of PDA types. With transcatheter occlusion technique and devices developing, more patients with PDA can be treated with transcatheter closure both safely and efficiently. PMID:26315073

  6. Update of transcatheter valve treatment

    PubMed Central

    Liu, Xian-bao; Wang, Jian-an

    2013-01-01

    Transcatheter valve implantation or repair has been a very promising approach for the treatment of valvular heart diseases since transcatheter aortic valve implantation (TAVI) was successfully performed in 2002. Great achievements have been made in this field (especially TAVI and transcatheter mitral valve repair—MitraClip system) in recent years. Evidence from clinical trials or registry studies has proved that transcatheter valve treatment for valvular heart diseases is safe and effective in surgical high-risk or inoperable patients. As the evidence accumulates, transcatheter valve treatment might be an alterative surgery for younger patients with surgically low or intermediate risk valvular heart diseases in the near future. In this paper, the updates on transcatheter valve treatment are reviewed. PMID:23897785

  7. A Workstation for Interactive Display and Quantitative Analysis of 3-D and 4-D Biomedical Images

    PubMed Central

    Robb, R.A.; Heffeman, P.B.; Camp, J.J.; Hanson, D.P.

    1986-01-01

    The capability to extract objective and quantitatively accurate information from 3-D radiographic biomedical images has not kept pace with the capabilities to produce the images themselves. This is rather an ironic paradox, since on the one hand the new 3-D and 4-D imaging capabilities promise significant potential for providing greater specificity and sensitivity (i.e., precise objective discrimination and accurate quantitative measurement of body tissue characteristics and function) in clinical diagnostic and basic investigative imaging procedures than ever possible before, but on the other hand, the momentous advances in computer and associated electronic imaging technology which have made these 3-D imaging capabilities possible have not been concomitantly developed for full exploitation of these capabilities. Therefore, we have developed a powerful new microcomputer-based system which permits detailed investigations and evaluation of 3-D and 4-D (dynamic 3-D) biomedical images. The system comprises a special workstation to which all the information in a large 3-D image data base is accessible for rapid display, manipulation, and measurement. The system provides important capabilities for simultaneously representing and analyzing both structural and functional data and their relationships in various organs of the body. This paper provides a detailed description of this system, as well as some of the rationale, background, theoretical concepts, and practical considerations related to system implementation. ImagesFigure 5Figure 7Figure 8Figure 9Figure 10Figure 11Figure 12Figure 13Figure 14Figure 15Figure 16

  8. Building foundations for transcatheter intervascular anastomoses: 3D anatomy of the great vessels in large experimental animals.

    PubMed

    Sizarov, Aleksander; de Bakker, Bernadette S; Klein, Karina; Ohlerth, Stefanie

    2014-10-01

    To provide comprehensive illustrations of anatomy of the relevant vessels in large experimental animals in an interactive format as preparation for developing an effective and safe transcatheter technique of aortopulmonary and bidirectional cavopulmonary intervascular anastomoses. Computed tomographic angiographic studies in two calves and two sheep were used to prepare 3D reconstructions of the aorta, pulmonary arteries, and caval and pulmonary veins. Based on these reconstructions, computer simulations of the creation of stent-enhanced aortopulmonary and bidirectional cavopulmonary anastomoses were made. We observed the following major anatomical features: (i) caudal course of the main pulmonary artery and its branches with the proximal right pulmonary artery located immediately caudal to the aortic arch, and with the central left pulmonary artery lying at a substantial distance from the descending aorta; and (ii) the distal right pulmonary artery is located dorsal to the right atrium and inferior caval vein at a substantial distance from the superior caval vein. Animations showed creation of transcatheter analogues of Waterston's and Potts' aortopulmonary shunts through placement of a covered spool-shaped stent, and the transcatheter creation of bidirectional Glenn's cavopulmonary anastomosis, by placement of a long covered trumpet-shaped stent. There are considerable differences in vascular anatomy between large experimental animals and humans. Given the need to elaborate new transcatheter techniques for intervascular anastomoses in suitable animal models before application to human, it is crucial to take these anatomical differences into account during testing and optimization of the proposed procedures. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  9. Quantitative flow and velocity measurements of pulsatile blood flow with 4D-DSA

    NASA Astrophysics Data System (ADS)

    Shaughnessy, Gabe; Hoffman, Carson; Schafer, Sebastian; Mistretta, Charles A.; Strother, Charles M.

    2017-03-01

    Time resolved 3D angiographic data from 4D DSA provides a unique environment to explore physical properties of blood flow. Utilizing the pulsatility of the contrast waveform, the Fourier components can be used to track the waveform motion through vessels. Areas of strong pulsatility are determined through the FFT power spectrum. Using this method, we find an accuracy from 4D-DSA flow measurements within 7.6% and 6.8% RMSE of ICA PCVIPR and phantom flow probe validation measurements, respectively. The availability of velocity and flow information with fast acquisition could provide a more quantitative approach to treatment planning and evaluation in interventional radiology.

  10. Quantitative assessment of paravalvular leakage after transcatheter aortic valve replacement using a patient-specific pulsatile flow model.

    PubMed

    Tanaka, Yutaka; Saito, Shigeru; Sasuga, Saeko; Takahashi, Azuma; Aoyama, Yusuke; Obama, Kazuto; Umezu, Mitsuo; Iwasaki, Kiyotaka

    2018-05-01

    Quantitative assessment of post-transcatheter aortic valve replacement (TAVR) aortic regurgitation (AR) remains challenging. We developed patient-specific anatomical models with pulsatile flow circuit and investigated factors associated with AR after TAVR. Based on pre-procedural computed tomography (CT) data of the six patients who underwent transfemoral TAVR using a 23-mm SAPIEN XT, anatomically and mechanically equivalent aortic valve models were developed. Forward flow and heart rate of each patient in two days after TAVR were duplicated under mean aortic pressure of 80mmHg. Paravalvular leakage (PVL) volume in basal and additional conditions was measured for each model using an electromagnetic flow sensor. Incompletely apposed tract between the transcatheter and aortic valves was examined using a micro-CT. PVL volume in each patient-specific model was consistent with each patient's PVL grade, and was affected by hemodynamic conditions. PVL and total regurgitation volume increased with the mean aortic pressure, whereas closing volume did not change. In contrast, closing volume increased proportionately with heart rate, but PVL did not change. The minimal cross-sectional gap had a positive correlation with the PVL volumes (r=0.89, P=0.02). The gap areas typically occurred in the vicinity of the bulky calcified nodules under the native commissure. PVL volume, which could be affected by hemodynamic conditions, was significantly associated with the minimal cross-sectional gap area between the aortic annulus and the stent frame. These data may improve our understanding of the mechanism of the occurrence of post-TAVR PVL. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  11. Accuracy and reproducibility of aortic annular measurements obtained from echocardiographic 3D manual and semi-automated software analyses in patients referred for transcatheter aortic valve implantation: implication for prosthesis size selection.

    PubMed

    Stella, Stefano; Italia, Leonardo; Geremia, Giulia; Rosa, Isabella; Ancona, Francesco; Marini, Claudia; Capogrosso, Cristina; Giglio, Manuela; Montorfano, Matteo; Latib, Azeem; Margonato, Alberto; Colombo, Antonio; Agricola, Eustachio

    2018-02-06

    A 3D transoesophageal echocardiography (3D-TOE) reconstruction tool has recently been introduced. The system automatically configures a geometric model of the aortic root and performs quantitative analysis of these structures. We compared the measurements of the aortic annulus (AA) obtained by semi-automated 3D-TOE quantitative software and manual analysis vs. multislice computed tomography (MSCT) ones. One hundred and seventy-five patients (mean age 81.3 ± 6.3 years, 77 men) who underwent both MSCT and 3D-TOE for annulus assessment before transcatheter aortic valve implantation were analysed. Hypothetical prosthetic valve sizing was evaluated using the 3D manual, semi-automated measurements using manufacturer-recommended CT-based sizing algorithm as gold standard. Good correlation between 3D-TOE methods vs. MSCT measurements was found, but the semi-automated analysis demonstrated slightly better correlations for AA major diameter (r = 0.89), perimeter (r = 0.89), and area (r = 0.85) (all P < 0.0001) than manual one. Both 3D methods underestimated the MSCT measurements, but semi-automated measurements showed narrower limits of agreement and lesser bias than manual measurements for most of AA parameters. On average, 3D-TOE semi-automated major diameter, area, and perimeter underestimated the respective MSCT measurements by 7.4%, 3.5%, and 4.4%, respectively, whereas minor diameter was overestimated by 0.3%. Moderate agreement for valve sizing for both 3D-TOE techniques was found: Kappa agreement 0.5 for both semi-automated and manual analysis. Interobserver and intraobserver agreements for the AA measurements were excellent for both techniques (intraclass correlation coefficients for all parameters >0.80). The 3D-TOE semi-automated analysis of AA is feasible and reliable and can be used in clinical practice as an alternative to MSCT for AA assessment. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author

  12. Quantitative Real-Time Fluoroscopy Analysis on Measurement of the Hepatic Arterial Flow During Transcatheter Arterial Chemoembolization of Hepatocellular Carcinoma: Comparison with Quantitative Digital Subtraction Angiography Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Yi-Yang; Lee, Rheun-Chuan, E-mail: rclee@vghtpe.gov.tw; Guo, Wan-Yuo, E-mail: wyguo@vghtpe.gov.tw

    PurposeTo quantify the arterial flow change during transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC) using digital subtraction angiography, quantitative color-coding analysis (d-QCA), and real-time subtraction fluoroscopy QCA (f-QCA).Materials and MethodsThis prospective study enrolled 20 consecutive patients with HCC who had undergone TACE via a subsegmental approach between February 2014 and April 2015. The TACE endpoint was a sluggish antegrade tumor-feeding arterial flow. d-QCA and f-QCA were used for determining the relative maximal density time (rT{sub max}) of the selected arteries. The rT{sub max} of the selected arteries was analyzed in d-QCA and f-QCA before and after TACE, and itsmore » correlation in both analyses was evaluated.ResultsThe pre- and post-TACE rT{sub max} of the embolized segmental artery in d-QCA and f-QCA were 1.59 ± 0.81 and 2.97 ± 1.80 s (P < 0.001) and 1.44 ± 0.52 and 2.28 ± 1.02 s (P < 0.01), respectively. The rT{sub max} of the proximal hepatic artery did not significantly change during TACE in d-QCA and f-QCA. The Spearman correlation coefficients of the pre- and post-TACE rT{sub max} of the embolized segmental artery between d-QCA and f-QCA were 0.46 (P < 0.05) and 0.80 (P < 0.001). Radiation doses in one series of d-QCA and f-QCA were 140.7 ± 51.5 milligray (mGy) and 2.5 ± 0.7 mGy, respectively.Conclusionsf-QCA can quantify arterial flow changes with a higher temporal resolution and lower radiation dose. Flow quantification of the embolized segmental artery using f-QCA and d-QCA is highly correlated.« less

  13. Quantitative 4D analyses of epithelial folding during Drosophila gastrulation.

    PubMed

    Khan, Zia; Wang, Yu-Chiun; Wieschaus, Eric F; Kaschube, Matthias

    2014-07-01

    Understanding the cellular and mechanical processes that underlie the shape changes of individual cells and their collective behaviors in a tissue during dynamic and complex morphogenetic events is currently one of the major frontiers in developmental biology. The advent of high-speed time-lapse microscopy and its use in monitoring the cellular events in fluorescently labeled developing organisms demonstrate tremendous promise in establishing detailed descriptions of these events and could potentially provide a foundation for subsequent hypothesis-driven research strategies. However, obtaining quantitative measurements of dynamic shapes and behaviors of cells and tissues in a rapidly developing metazoan embryo using time-lapse 3D microscopy remains technically challenging, with the main hurdle being the shortage of robust imaging processing and analysis tools. We have developed EDGE4D, a software tool for segmenting and tracking membrane-labeled cells using multi-photon microscopy data. Our results demonstrate that EDGE4D enables quantification of the dynamics of cell shape changes, cell interfaces and neighbor relations at single-cell resolution during a complex epithelial folding event in the early Drosophila embryo. We expect this tool to be broadly useful for the analysis of epithelial cell geometries and movements in a wide variety of developmental contexts. © 2014. Published by The Company of Biologists Ltd.

  14. Prosthesis-patient mismatch after transcatheter aortic valve implantation: impact of 2D-transthoracic echocardiography versus 3D-transesophageal echocardiography.

    PubMed

    da Silva, Cristina; Sahlen, Anders; Winter, Reidar; Bäck, Magnus; Rück, Andreas; Settergren, Magnus; Manouras, Aristomenis; Shahgaldi, Kambiz

    2014-12-01

    To investigate the role of 2D-transthoracic echocardiography (2D-TTE) and 3D-transesophageal echocardiography (3D-TEE) in the determination of aortic annulus size prior transcatheter aortic valve implantation (TAVI) and its' impact on the prevalence of patient prosthesis mismatch (PPM). Echocardiography plays an important role in measuring aortic annulus dimension in patients undergoing TAVI. This has great importance since it determines both eligibility for TAVI and selection of prosthesis type and size, and can be potentially important in preventing an inadequate ratio between the prosthetic valvular orifice and the patient's body surface area, concept known as prosthesis-patient mismatch (PPM). A total of 45 patients were studied pre-TAVI: 20 underwent 3D-TEE (men/women 12/8, age 84.8 ± 5.6) and 25 2D-TTE (men/women 9/16, age 84.4 ± 5.4) in order to measure aortic annulus diameter. The presence of PPM was assessed before hospital discharge and after a mean period of 3 months. Moderate PPM was defined as indexed aortic valve area (AVAi) ≤ 0.85 cm(2)/m(2) and severe PPM as AVAi < 0.65 cm(2)/m(2). Immediately post-TAVI, moderate PPM was present in 25 and 28 % of patients worked up using 3D-TEE and 2D-TTE respectively p value = n.s) and severe PPM occurred in 10 % of the patients who underwent 3D-TEE and in 20 % in those with 2D-TTE (p value = n.s). The echocardiographic evaluation 3 months post-TAVI showed 25 % moderate PPM in the 3D-TEE group compared with 24 % in the 2D-TTE group (p value = n.s) and no cases of severe PPM in the 3DTEE group comparing to 20 % in the 2D-TTE group (p = 0.032). Our results indicate a higher incidence of severe PPM in patients who performed 2DTTE compared to those performing 3DTEE prior TAVI. This suggests that the 3D technique should replace the 2DTTE analysis when investigating the aortic annulus diameter in patients undergoing TAVI.

  15. Anesthetic Considerations for Transcatheter Pulmonary Valve Replacement.

    PubMed

    Gregory, Stephen H; Zoller, Jonathan K; Shahanavaz, Shabana; Chilson, Kelly L; Ridley, Clare H

    2018-02-01

    The introduction of transcatheter therapy for valvular heart disease has revolutionized the care of patients with valvular disorders. Pathologic regurgitation or stenosis of the pulmonary valve, right ventricular outflow tract, or a right ventricle-to-pulmonary artery conduit represent emerging indications for transcatheter therapy. To date, minimal literature exists detailing the anesthetic management of patients undergoing transcatheter pulmonary valve replacement. In this review, the pathophysiology and indications for transcatheter pulmonary valve replacement and possible complications unique to this procedure are reviewed. Anesthetic management, including preoperative assessment, intraoperative considerations, and early postoperative monitoring, are discussed. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Catheter tracking via online learning for dynamic motion compensation in transcatheter aortic valve implantation.

    PubMed

    Wang, Peng; Zheng, Yefeng; John, Matthias; Comaniciu, Dorin

    2012-01-01

    Dynamic overlay of 3D models onto 2D X-ray images has important applications in image guided interventions. In this paper, we present a novel catheter tracking for motion compensation in the Transcatheter Aortic Valve Implantation (TAVI). To address such challenges as catheter shape and appearance changes, occlusions, and distractions from cluttered backgrounds, we present an adaptive linear discriminant learning method to build a measurement model online to distinguish catheters from background. An analytic solution is developed to effectively and efficiently update the discriminant model and to minimize the classification errors between the tracking object and backgrounds. The online learned discriminant model is further combined with an offline learned detector and robust template matching in a Bayesian tracking framework. Quantitative evaluations demonstrate the advantages of this method over current state-of-the-art tracking methods in tracking catheters for clinical applications.

  17. Transcatheter Patent Ductus Arteriosus Occlusion in Small Infants.

    PubMed

    Schwartz, Matthew C; Nykanen, David; Winner, Lawrence H; Perez, Jose; McMahan, Michael; Munro, Hamish M; Suguna Narasimhulu, Sukumar

    2016-12-01

    Transcatheter patent ductus arteriosus (PDA) occlusion is feasible in small infants and may improve lung function in symptomatic patients. We aimed to describe transcatheter PDA closure in small infants including predictors of technical success and rate of complication and to identify factors associated with improved respiratory status after closure. All patients in the NICU at our center who were referred for transcatheter PDA occlusion between 1/2010 and 11/2014 were retrospectively identified. Relevant details were extracted. Additionally, a modification of the respiratory severity score (RSS) (FiO 2 × mean airway pressure) was used to characterize degree of pulmonary support before and at intervals after catheterization. Twenty patients were identified with median age of 96 days (13-247) and weight of 3.1 kg (1.7-4.7). The PDA was type F morphology in 14 (70%) patients. The PDA was successfully occluded in 16 (80%) patients. Ratio of minimum PDA diameter/length was >0.5 in all unsuccessful attempts and <0.4 in all successful cases (P = .01). Of the 16 cases of occlusion, Amplatzer Vascular Plug II was used in 15 (94%). No deaths or pulse loss occurred. Five (25%) patients required blood transfusion and transfusion was associated with lower hemoglobin (P = .049), lower weight (P = .008), and lower aortic pressure (P = .04). Excluding 1 patient with significant congenital heart disease, the RSS improved at 3 days in 9 (60%) patients and at 7 days in 12 (80%) compared with preintervention value. Patient factors were not associated with improved RSS at 3 or 7 days. In our cohort of symptomatic infants, transcatheter PDA occlusion was successful in most and a ratio of minimum PDA diameter/length of <0.4 was predictive of technical success. Using a surrogate for pulmonary support, the majority of patients were on less support 7 days after closure. © 2016 Wiley Periodicals, Inc.

  18. Transcatheter closure of patent ductus arteriosus: past, present and future.

    PubMed

    Baruteau, Alban-Elouen; Hascoët, Sébastien; Baruteau, Julien; Boudjemline, Younes; Lambert, Virginie; Angel, Claude-Yves; Belli, Emre; Petit, Jérôme; Pass, Robert

    2014-02-01

    This review aims to describe the past history, present techniques and future directions in transcatheter treatment of patent ductus arteriosus (PDA). Transcatheter PDA closure is the standard of care in most cases and PDA closure is indicated in any patient with signs of left ventricular volume overload due to a ductus. In cases of left-to-right PDA with severe pulmonary arterial hypertension, closure may be performed under specific conditions. The management of clinically silent or very tiny PDAs remains highly controversial. Techniques have evolved and the transcatheter approach to PDA closure is now feasible and safe with current devices. Coils and the Amplatzer Duct Occluder are used most frequently for PDA closure worldwide, with a high occlusion rate and few complications. Transcatheter PDA closure in preterm or low-bodyweight infants remains a highly challenging procedure and further device and catheter design development is indicated before transcatheter closure is the treatment of choice in this delicate patient population. The evolution of transcatheter PDA closure from just 40 years ago with 18F sheaths to device delivery via a 3F sheath is remarkable and it is anticipated that further improvements will result in better safety and efficacy of transcatheter PDA closure techniques. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  19. Transcatheter Aortic Valve Replacement for Native Aortic Valve Regurgitation

    PubMed Central

    Spina, Roberto; Anthony, Chris; Muller, David WM

    2015-01-01

    Transcatheter aortic valve replacement with either the balloon-expandable Edwards SAPIEN XT valve, or the self-expandable CoreValve prosthesis has become the established therapeutic modality for severe aortic valve stenosis in patients who are not deemed suitable for surgical intervention due to excessively high operative risk. Native aortic valve regurgitation, defined as primary aortic incompetence not associated with aortic stenosis or failed valve replacement, on the other hand, is still considered a relative contraindication for transcatheter aortic valve therapies, because of the absence of annular or leaflet calcification required for secure anchoring of the transcatheter heart valve. In addition, severe aortic regurgitation often coexists with aortic root or ascending aorta dilatation, the treatment of which mandates operative intervention. For these reasons, transcatheter aortic valve replacement has been only sporadically used to treat pure aortic incompetence, typically on a compassionate basis and in surgically inoperable patients. More recently, however, transcatheter aortic valve replacement for native aortic valve regurgitation has been trialled with newer-generation heart valves, with encouraging results, and new ancillary devices have emerged that are designed to stabilize the annulus–root complex. In this paper we review the clinical context, technical characteristics and outcomes associated with transcatheter treatment of native aortic valve regurgitation. PMID:29588674

  20. Recently patented transcatheter aortic valves in clinical trials.

    PubMed

    Neragi-Miandoab, Siyamek; Skripochnik, Edvard; Salemi, Arash; Girardi, Leonard

    2013-12-01

    The most widely used heart valve worldwide is the Edwards Sapien, which currently has 60% of the worldwide transcatheter aortic valve implantation (TAVI) market. The CoreValve is next in line in popularity, encompassing 35% of the worldwide TAVI market. Although these two valves dominate the TAVI market, a number of newer transcatheter valves have been introduced and others are in early clinical evaluation. The new valves are designed to reduce catheter delivery diameter, improve ease of positioning and sealing, and facilitate repositioning or removal. The most recent transcatheter valves for transapical use include Acurate TA (Symetis), Engager (Medtronic), and JenaValve the Portico (St Jude), Sadra Lotus Medical (Boston Scientific), and the Direct Flow Medical. These new inventions may introduce more effective treatment options for high-risk patients with severe aortic stenosis. Improvements in transcatheter valves and the developing variability among them may allow for more tailored approaches with respect to patient's anatomy, while giving operators the opportunity to choose devices they feel more comfortable with. Moreover, introducing new devices to the market will create a competitive environment among producers that will reduce high prices and expand availability. The present review article includes a discussion of recent patents related to Transcatheter Aortic Valves.

  1. Valve thrombosis following transcatheter aortic valve implantation: a systematic review.

    PubMed

    Córdoba-Soriano, Juan G; Puri, Rishi; Amat-Santos, Ignacio; Ribeiro, Henrique B; Abdul-Jawad Altisent, Omar; del Trigo, María; Paradis, Jean-Michel; Dumont, Eric; Urena, Marina; Rodés-Cabau, Josep

    2015-03-01

    Despite the rapid global uptake of transcatheter aortic valve implantation, valve trombosis has yet to be systematically evaluated in this field. The aim of this study was to determine the clinical characteristics, diagnostic criteria, and treatment outcomes of patients diagnosed with valve thrombosis following transcatheter aortic valve implantation through a systematic review of published data. Literature published between 2002 and 2012 on valve thrombosis as a complication of transcatheter aortic valve implantation was identified through a systematic electronic search. A total of 11 publications were identified, describing 16 patients (mean age, 80 [5] years, 65% men). All but 1 patient (94%) received a balloon-expandable valve. All patients received dual antiplatelet therapy immediately following the procedure and continued to take either mono- or dual antiplatelet therapy at the time of valve thrombosis diagnosis. Valve thrombosis was diagnosed at a median of 6 months post-procedure, with progressive dyspnea being the most common symptom. A significant increase in transvalvular gradient (from 10 [4] to 40 [12] mmHg) was the most common echocardiographic feature, in addition to leaflet thickening. Thrombus was not directly visualized with echocardiography. Three patients underwent valve explantation, and the remaining received warfarin, which effectively restored the mean transvalvular gradient to baseline within 2 months. Systemic embolism was not a feature of valve thrombosis post-transcatheter aortic valve implantation. Although a rare, yet likely under-reported complication of post-transcatheter aortic valve implantation, progressive dyspnea coupled with an increasing transvalvular gradient on echocardiography within the months following the intervention likely signifies valve thrombosis. While direct thrombus visualization appears difficult, prompt initiation of oral anticoagulation therapy effectively restores baseline valve function. Copyright © 2014

  2. Association of CKD with Outcomes Among Patients Undergoing Transcatheter Aortic Valve Implantation

    PubMed Central

    Kaier, Klaus; Kaleschke, Gerrit; Gebauer, Katrin; Meyborg, Matthias; Malyar, Nasser M.; Freisinger, Eva; Baumgartner, Helmut; Reinecke, Holger; Reinöhl, Jochen

    2017-01-01

    Background and objectives Despitethe multiple depicted associations of CKD with reduced cardiovascular and overall prognoses, the association of CKD with outcome of patients undergoing transcatheter aortic valve implantation has still not been well described. Design, setting, participants, & measurements Data from all hospitalized patients who underwent transcatheter aortic valve implantation procedures between January 1, 2010 and December 31, 2013 in Germany were evaluated regarding influence of CKD, even in the earlier stages, on morbidity, in-hospital outcomes, and costs. Results A total of 28,716 patients were treated with transcatheter aortic valve implantation. A total of 11,189 (39.0%) suffered from CKD. Patients with CKD were predominantly women; had higher rates of comorbidities, such as coronary artery disease, heart failure at New York Heart Association 3/4, peripheral artery disease, and diabetes; and had a 1.3-fold higher estimated logistic European System for Cardiac Operative Risk Evaluation value. In-hospital mortality was independently associated with CKD stage ≥3 (up to odds ratio, 1.71; 95% confidence interval, 1.35 to 2.17; P<0.05), bleeding was independently associated with CKD stage ≥4 (up to odds ratio, 1.82; 95% confidence interval, 1.47 to 2.24; P<0.001), and AKI was independently associated with CKD stages 3 (odds ratio, 1.83; 95% confidence interval, 1.62 to 2.06) and 4 (odds ratio, 2.33; 95% confidence interval, 1.92 to 2.83 both P<0.001). The stroke risk, in contrast, was lower for patients with CKD stages 4 (odds ratio, 0.23; 95% confidence interval, 0.16 to 0.33) and 5 (odds ratio, 0.24; 95% confidence interval, 0.15 to 0.39; both P<0.001). Lengths of hospital stay were, on average, 1.2-fold longer, whereas reimbursements were, on average, only 1.03-fold higher in patients who suffered from CKD. Conclusions This analysis illustrates for the first time on a nationwide basis the association of CKD with adverse outcomes in patients

  3. Association of CKD with Outcomes Among Patients Undergoing Transcatheter Aortic Valve Implantation.

    PubMed

    Lüders, Florian; Kaier, Klaus; Kaleschke, Gerrit; Gebauer, Katrin; Meyborg, Matthias; Malyar, Nasser M; Freisinger, Eva; Baumgartner, Helmut; Reinecke, Holger; Reinöhl, Jochen

    2017-05-08

    Despitethe multiple depicted associations of CKD with reduced cardiovascular and overall prognoses, the association of CKD with outcome of patients undergoing transcatheter aortic valve implantation has still not been well described. Data from all hospitalized patients who underwent transcatheter aortic valve implantation procedures between January 1, 2010 and December 31, 2013 in Germany were evaluated regarding influence of CKD, even in the earlier stages, on morbidity, in-hospital outcomes, and costs. A total of 28,716 patients were treated with transcatheter aortic valve implantation. A total of 11,189 (39.0%) suffered from CKD. Patients with CKD were predominantly women; had higher rates of comorbidities, such as coronary artery disease, heart failure at New York Heart Association 3/4, peripheral artery disease, and diabetes; and had a 1.3-fold higher estimated logistic European System for Cardiac Operative Risk Evaluation value. In-hospital mortality was independently associated with CKD stage ≥3 (up to odds ratio, 1.71; 95% confidence interval, 1.35 to 2.17; P <0.05), bleeding was independently associated with CKD stage ≥4 (up to odds ratio, 1.82; 95% confidence interval, 1.47 to 2.24; P <0.001), and AKI was independently associated with CKD stages 3 (odds ratio, 1.83; 95% confidence interval, 1.62 to 2.06) and 4 (odds ratio, 2.33; 95% confidence interval, 1.92 to 2.83 both P <0.001). The stroke risk, in contrast, was lower for patients with CKD stages 4 (odds ratio, 0.23; 95% confidence interval, 0.16 to 0.33) and 5 (odds ratio, 0.24; 95% confidence interval, 0.15 to 0.39; both P <0.001). Lengths of hospital stay were, on average, 1.2-fold longer, whereas reimbursements were, on average, only 1.03-fold higher in patients who suffered from CKD. This analysis illustrates for the first time on a nationwide basis the association of CKD with adverse outcomes in patients who underwent transcatheter aortic valve implantation. Thus, classification of CKD stages

  4. Transcatheter Heart Valve Selection and Permanent Pacemaker Implantation in Patients With Pre-Existent Right Bundle Branch Block.

    PubMed

    van Gils, Lennart; Tchetche, Didier; Lhermusier, Thibault; Abawi, Masieh; Dumonteil, Nicolas; Rodriguez Olivares, Ramón; Molina-Martin de Nicolas, Javier; Stella, Pieter R; Carrié, Didier; De Jaegere, Peter P; Van Mieghem, Nicolas M

    2017-03-03

    Right bundle branch block is an established predictor for new conduction disturbances and need for a permanent pacemaker (PPM) after transcatheter aortic valve replacement. The aim of the study was to evaluate the absolute rates of transcatheter aortic valve replacement related PPM implantations in patients with pre-existent right bundle branch block and categorize for different transcatheter heart valves. We pooled data on 306 transcatheter aortic valve replacement patients from 4 high-volume centers in Europe and selected those with right bundle branch block at baseline without a previously implanted PPM. Logistic regression was used to evaluate whether PPM rate differed among transcatheter heart valves after adjustment for confounders. Mean age was 83±7 years and 63% were male. Median Society of Thoracic Surgeons score was 6.3 (interquartile range, 4.1-10.2). The following transcatheter valve designs were used: Medtronic CoreValve (n=130; Medtronic, Minneapolis, MN); Edwards Sapien XT (ES-XT; n=124) and Edwards Sapien 3 (ES-3; n=32; Edwards Lifesciences, Irvine, CA); and Boston Scientific Lotus (n=20; Boston Scientific Corporation, Marlborough, MA). Overall permanent pacemaker implantation rate post-transcatheter aortic valve replacement was 41%, and per valve design: 75% with Lotus, 46% with CoreValve, 32% with ES-XT, and 34% with ES-3. The indication for PPM implantation was total atrioventricular block in 98% of the cases. Lotus was associated with a higher PPM rate than all other valves. PPM rate did not differ between ES-XT and ES-3. Ventricular paced rhythm at 30-day and 1-year follow-up was present in 81% at 89%, respectively. Right bundle branch block at baseline is associated with a high incidence of PPM implantation for all transcatheter heart valves. PPM rate was highest for Lotus and lowest for ES-XT and ES-3. Pacemaker dependency remained high during follow-up. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by

  5. Transcatheter intervention for the treatment of congenital cardiac defects.

    PubMed Central

    Grifka, R G

    1997-01-01

    Cardiac catheterization has an illustrious history, originating in 1929 when Werner Forsmann, a surgical resident, performed a heart catheterization on himself. Transcatheter interventional procedures have been performed since the 1960s. The 1st intracardiac procedure to become standard therapy was a balloon atrial septostomy. Skeptics attacked this innovative procedure. However, the balloon septostomy procedure soon became the standard emergency procedure for certain congenital heart defects, and was the impetus for other investigators in the field of transcatheter intervention. We will discuss transcatheter treatment for congenital vascular stenoses and vascular occlusion. Images PMID:9456482

  6. Transcatheter Closure of Patent Foramen Ovale: A Single Center Experience.

    PubMed

    Milev, Ivan; Zafirovska, Planinka; Zimbakov, Zan; Idrizi, Shpend; Ampova-Sokolov, Vilma; Gorgieva, Emilija; Ilievska, Liljana; Tosheski, Goce; Hristov, Nikola; Georgievska-Ismail, Ljubica; Anguseva, Tanja; Mitrev, Zan

    2016-12-15

    Percutaneous transcatheter closure (PTC) of patent foramen ovale (PFO) is implicated in cryptogenic stroke, transitional ischemic attack (TIA) and treatment of a migraine. Our goal was to present our experience in the interventional treatment of PFO, as well as to evaluate the short and mid-term results in patients with closed PFO. Transcatheter closure of PFO was performed in 52 patients (67.3% women, mean age 40.7 ± 11.7 years). Patients were interviewed for subjective grading of the intensity of headaches before and after the PFO closure. During 2 years of follow-up, there was no incidence of new stroke, TIA and/or syncope. Follow-up TCD performed in 35 patients showed complete PFO closure in 20 patients (57.1%). Out of 35 patients, 22 (62.9%) reported having a migraine before the procedure with an intensity of headaches at 8.1 ± 1.9 on a scale from 1 to 10. During 2 years of follow-up, symptoms of a migraine disappeared in 4 (18.2%) and the remaining 18 patients reported the significant decrease in intensity 4.8 ± 2.04 (p = 0.0001). In addition, following PFO closure the incidence of the headaches decreased significantly (p = 0.0001). Percutaneous transcatheter closure of PFO is a safe and effective procedure showing mid-term relief of neurological symptoms in patients as well as significant reduction of migraine symptoms.

  7. Transcatheter aortic-valve replacement with a self-expanding prosthesis.

    PubMed

    Adams, David H; Popma, Jeffrey J; Reardon, Michael J; Yakubov, Steven J; Coselli, Joseph S; Deeb, G Michael; Gleason, Thomas G; Buchbinder, Maurice; Hermiller, James; Kleiman, Neal S; Chetcuti, Stan; Heiser, John; Merhi, William; Zorn, George; Tadros, Peter; Robinson, Newell; Petrossian, George; Hughes, G Chad; Harrison, J Kevin; Conte, John; Maini, Brijeshwar; Mumtaz, Mubashir; Chenoweth, Sharla; Oh, Jae K

    2014-05-08

    We compared transcatheter aortic-valve replacement (TAVR), using a self-expanding transcatheter aortic-valve bioprosthesis, with surgical aortic-valve replacement in patients with severe aortic stenosis and an increased risk of death during surgery. We recruited patients with severe aortic stenosis who were at increased surgical risk as determined by the heart team at each study center. Risk assessment included the Society of Thoracic Surgeons Predictor Risk of Mortality estimate and consideration of other key risk factors. Eligible patients were randomly assigned in a 1:1 ratio to TAVR with the self-expanding transcatheter valve (TAVR group) or to surgical aortic-valve replacement (surgical group). The primary end point was the rate of death from any cause at 1 year, evaluated with the use of both noninferiority and superiority testing. A total of 795 patients underwent randomization at 45 centers in the United States. In the as-treated analysis, the rate of death from any cause at 1 year was significantly lower in the TAVR group than in the surgical group (14.2% vs. 19.1%), with an absolute reduction in risk of 4.9 percentage points (upper boundary of the 95% confidence interval, -0.4; P<0.001 for noninferiority; P = 0.04 for superiority). The results were similar in the intention-to-treat analysis. In a hierarchical testing procedure, TAVR was noninferior with respect to echocardiographic indexes of valve stenosis, functional status, and quality of life. Exploratory analyses suggested a reduction in the rate of major adverse cardiovascular and cerebrovascular events and no increase in the risk of stroke. In patients with severe aortic stenosis who are at increased surgical risk, TAVR with a self-expanding transcatheter aortic-valve bioprosthesis was associated with a significantly higher rate of survival at 1 year than surgical aortic-valve replacement. (Funded by Medtronic; U.S. CoreValve High Risk Study ClinicalTrials.gov number, NCT01240902.).

  8. Quality and Safety in Health Care, Part XXX: Transcatheter Aortic Valve Therapy.

    PubMed

    Harolds, Jay A

    2017-12-01

    Initially, the transcatheter aortic valve replacement procedure was approved only for patients with aortic stenosis that was both severe and symptomatic who either also had too high a risk of aortic valve replacement surgery to have the surgery or who had a high risk for the surgery. Between the years 2012 and 2015, the death rate at 30 days declined from an initial rate of 7.5% to 4.6%. There has also been more use of the transfemoral approach over the years. In 2016, the transcatheter aortic valve replacement was approved for patients with aortic stenosis at intermediate risk of surgery.

  9. Transcatheter closure of patent ductus arteriosus: 11 years of clinical experience in Cipto Mangunkusumo Hospital, Jakarta, Indonesia.

    PubMed

    Djer, Mulyadi M; Saputro, Dimas Dwi; Putra, Sukman Tulus; Idris, Nikmah Salamia

    2015-06-01

    Transcatheter closure of patent ductus arteriosus (PDA) has been suggested to be the standard treatment of PDA. Although, in general, the procedure shows a high successful rate, outcomes may vary among pediatric cardiology centers. To evaluate the effectiveness of transcatheter closure of PDA in Cipto Mangunkusumo Hospital, Jakarta, Indonesia, this was a retrospective study on patients who underwent transcatheter closure of PDA in Cipto Mangunkusumo Hospital during the period of 2002-2013. Hospital registry was reviewed and data about patients' characteristics, PDA severity, procedure, and outcomes were retrieved. There were 298 patients, of whom 90 were males, who underwent transcatheter closure of PDA during the study period. Median age was 3.4 years (1 months-18 years), and median body weight was 12 (3.6-59) kg. The diameter of PDA ranged from 1.1 to 15.4 mm with a median of 3.7 mm. Device could be deployed in all patients, in which most were the Amplatzer ductal occluder (69.8 %) and the remainders were coils. Median fluoroscopy time was 15.4 (1.5-87) min, and procedure time was 76 (30-200) min. Complete closure was achieved in most patients (97.3 %), whereas device migration occurred in a minority (0.3 %) of patients. No major complication occurred during or after the procedure. Transient anemia and bradycardia were found in 3.7 and 1.3 % patients, respectively. Most patients were discharged from the hospital at 1 day after the procedure. Transcatheter closure method is a safe and effective procedure to close PDA.

  10. Transapical aortic valve implantation in Rouen: four years' experience with the Edwards transcatheter prosthesis.

    PubMed

    Litzler, Pierre-Yves; Borz, Bogdan; Smail, Hassiba; Baste, Jean-Marc; Nafeh-Bizet, Catherine; Gay, Arnaud; Tron, Christophe; Godin, Matthieu; Caudron, Jerome; Hauville, Camille; Dacher, Jean-Nicolas; Cribier, Alain; Eltchaninoff, Hélène; Bessou, Jean-Paul

    2012-03-01

    The first French transapical transcatheter aortic valve implantation (TAVI) was performed in July 2007 in our department. To report 4-year outcomes of transapical implantation with the Edwards transcatheter bioprosthesis. We prospectively evaluated consecutive patients who underwent transapical implantation with an Edwards transcatheter bioprosthesis between July 2007 and October 2011. Patients were not suitable for conventional surgery (due to severe comorbidities) or transfemoral implantation (due to poor femoral access). Among 61 patients (59.0% men), mean logistic EuroSCORE was 27.5 ± 14.9% and mean age was 81.0 ± 6.8 years. Successful valve implantation was achieved in 59/61 patients (96.7%) of patients. The other two patients required conversion to conventional surgery due to prosthesis embolization and died. Six additional patients died in the postoperative period. Causes of perioperative death were two septic shocks (one of peritonitis), two multi-organ failure, one ventricular fibrillation and one respiratory insufficiency. Intraprocedural stroke was not observed in any patient. The actuarial survival rates at 1, 2 and 4 years were 73.8%, 67.2% and 41.0%. During this 4-year period, four patients died of cardiovascular events, but no impairment of transprosthesis gradient was observed. Our series of 61 patients who underwent transapical implantation of the Edwards transcatheter bioprosthesis shows satisfactory results, similar to other reports, considering the high level of severity of patients referred for this method. Transapical access is a reliable alternative method for patients that cannot benefit from a transfemoral approach. Copyright © 2012. Published by Elsevier Masson SAS.

  11. SU-E-QI-17: Dependence of 3D/4D PET Quantitative Image Features On Noise

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oliver, J; Budzevich, M; Zhang, G

    2014-06-15

    Purpose: Quantitative imaging is a fast evolving discipline where a large number of features are extracted from images; i.e., radiomics. Some features have been shown to have diagnostic, prognostic and predictive value. However, they are sensitive to acquisition and processing factors; e.g., noise. In this study noise was added to positron emission tomography (PET) images to determine how features were affected by noise. Methods: Three levels of Gaussian noise were added to 8 lung cancer patients PET images acquired in 3D mode (static) and using respiratory tracking (4D); for the latter images from one of 10 phases were used. Amore » total of 62 features: 14 shape, 19 intensity (1stO), 18 GLCM textures (2ndO; from grey level co-occurrence matrices) and 11 RLM textures (2ndO; from run-length matrices) features were extracted from segmented tumors. Dimensions of GLCM were 256×256, calculated using 3D images with a step size of 1 voxel in 13 directions. Grey levels were binned into 256 levels for RLM and features were calculated in all 13 directions. Results: Feature variation generally increased with noise. Shape features were the most stable while RLM were the most unstable. Intensity and GLCM features performed well; the latter being more robust. The most stable 1stO features were compactness, maximum and minimum length, standard deviation, root-mean-squared, I30, V10-V90, and entropy. The most stable 2ndO features were entropy, sum-average, sum-entropy, difference-average, difference-variance, difference-entropy, information-correlation-2, short-run-emphasis, long-run-emphasis, and run-percentage. In general, features computed from images from one of the phases of 4D scans were more stable than from 3D scans. Conclusion: This study shows the need to characterize image features carefully before they are used in research and medical applications. It also shows that the performance of features, and thereby feature selection, may be assessed in part by noise

  12. A comparison of conventional surgery, transcatheter aortic valve replacement, and sutureless valves in "real-world" patients with aortic stenosis and intermediate- to high-risk profile.

    PubMed

    Muneretto, Claudio; Alfieri, Ottavio; Cesana, Bruno Mario; Bisleri, Gianluigi; De Bonis, Michele; Di Bartolomeo, Roberto; Savini, Carlo; Folesani, Gianluca; Di Bacco, Lorenzo; Rambaldini, Manfredo; Maureira, Juan Pablo; Laborde, Francois; Tespili, Maurizio; Repossini, Alberto; Folliguet, Thierry

    2015-12-01

    We sought to investigate the clinical outcomes of patients with isolated severe aortic stenosis and an intermediate- to high-risk profile treated by means of conventional surgery (surgical aortic valve replacement), sutureless valve implantation, or transcatheter aortic valve replacement in a multicenter evaluation. Among 991 consecutive patients with isolated severe aortic stenosis and an intermediate- to high-risk profile (Society of Thoracic Surgeons score >4 and logistic European System for Cardiac Operative Risk Evaluation I >10), a propensity score analysis was performed on the basis of the therapeutic strategy: surgical aortic valve replacement (n = 204), sutureless valve implantation (n = 204), and transcatheter aortic valve replacement (n = 204). Primary end points were 30-day mortality and overall survival at 24-month follow-up; the secondary end point was survival free from a composite end point of major adverse cardiac events (defined as cardiac-related mortality, myocardial infarction, cerebrovascular accidents, and major hemorrhagic events) and periprosthetic regurgitation greater than 2. Thirty-day mortality was significantly higher in the transcatheter aortic valve replacement group (surgical aortic valve replacement = 3.4% vs sutureless = 5.8% vs transcatheter aortic valve replacement = 9.8%; P = .005). The incidence of postprocedural was 3.9% in asurgical aortic valve replacement vs 9.8% in sutureless vs 14.7% in transcatheter aortic valve replacement (P< .001) and peripheral vascular complications occurred in 0% of surgicalaortic valve replacement vs 0% of sutureless vs 9.8% transcatheter aortic valve replacement (P< .001). At 24-month follow-up, overall survival (surgical aortic valve replacement = 91.3% ± 2.4% vs sutureless = 94.9% ± 2.1% vs transcatheter aortic valve replacement = 79.5% ± 4.3%; P < .001) and survival free from the composite end point of major adverse cardiovascular events and periprosthetic regurgitation were significantly

  13. Transcatheter closure of patent ductus arteriosus with Nit-Occlud coils.

    PubMed

    Celiker, Alpay; Aypar, Ebru; Karagöz, Tevfik; Dilber, Embiya; Ceviz, Naci

    2005-08-01

    The detachable coils have been successfully used for transcatheter occlusion of small- to moderate-sized patent ductus arteriosus (PDA). We report our experience regarding the use of the Nit-Occlud coils (NOCs) for transcatheter PDA and major aortopulmonary collateral (MAPCA) occlusion. Single NOCs were used to close PDA in 26 patients, and one small and two large MAPCAs in two patients. Mean age and weight of the patients were 7.7 +/- 5.4 years and 20.6 +/- 11.6 kg. Mean minimum duct diameter was 2.8 +/- 0.8 mm; ampulla, 8.7 +/- 2.4 mm; and PDA length, 9.3 +/- 4.4 mm. Mean pulmonary artery pressure ranged from 9 to 51 mm Hg and pulmonary/systemic flow ratio from 1.1 to 5.8. Ductal shape was conical in 24 patients. Route of approach was venous in 23 and arterial in 3. Successful coil implantation was achieved in 24/26 (92.3%). Mean procedure and fluoroscopy time were 67.2 +/- 22.1 and 14.9 +/- 6.5 min. The three MAPCAs were also successfully occluded using NOC Medium and Flex. Postimplantation angiograms revealed no leak in 3, a trace or small leak in 17, and a medium leak in 4 patients. Mean follow-up was 7 +/- 5 months. Complete occlusion was achieved in 17/24 (71%) at 24 hr, 19/24 (79%) by 1 month, 13/15 (87%) by 3 months, 14/15 (93%) by 6 months, and 10/11 (90%) by 12 months postprocedure. Hemolysis, late embolization, duct recanalization, and flow disturbances were not observed. Transcatheter occlusion of moderate-sized PDAs and MAPCAs using NOCs seems to offer a safe, simple, and controlled method in pediatric patients.

  14. Transcatheter Closure of Patent Foramen Ovale: A Single Center Experience

    PubMed Central

    Milev, Ivan; Zafirovska, Planinka; Zimbakov, Zan; Idrizi, Shpend; Ampova-Sokolov, Vilma; Gorgieva, Emilija; Ilievska, Liljana; Tosheski, Goce; Hristov, Nikola; Georgievska-Ismail, Ljubica; Anguseva, Tanja; Mitrev, Zan

    2016-01-01

    BACKGROUND: Percutaneous transcatheter closure (PTC) of patent foramen ovale (PFO) is implicated in cryptogenic stroke, transitional ischemic attack (TIA) and treatment of a migraine. AIM: Our goal was to present our experience in the interventional treatment of PFO, as well as to evaluate the short and mid-term results in patients with closed PFO. MATERIAL AND METHODS: Transcatheter closure of PFO was performed in 52 patients (67.3% women, mean age 40.7 ± 11.7 years). Patients were interviewed for subjective grading of the intensity of headaches before and after the PFO closure. RESULTS: During 2 years of follow-up, there was no incidence of new stroke, TIA and/or syncope. Follow-up TCD performed in 35 patients showed complete PFO closure in 20 patients (57.1%). Out of 35 patients, 22 (62.9%) reported having a migraine before the procedure with an intensity of headaches at 8.1 ± 1.9 on a scale from 1 to 10. During 2 years of follow-up, symptoms of a migraine disappeared in 4 (18.2%) and the remaining 18 patients reported the significant decrease in intensity 4.8 ± 2.04 (p = 0.0001). In addition, following PFO closure the incidence of the headaches decreased significantly (p = 0.0001). CONCLUSIONS: Percutaneous transcatheter closure of PFO is a safe and effective procedure showing mid-term relief of neurological symptoms in patients as well as significant reduction of migraine symptoms. PMID:28028400

  15. Fatal overdose of 2,4-dichlorophenoxyacetic acid (2,4-D).

    PubMed

    Keller, T; Skopp, G; Wu, M; Aderjan, R

    1994-03-01

    An ingestion of an unknown quantity of U 46 D-Fluid (500 g dichlorophenoxyacetic acid/l) in a suicide is described. Although 2,4-dichlorophenoxyacetic acid (2,4 D) is widely used as a herbicide, intoxications are relatively rare. Quantitation of 2,4-D was performed by diethyl ether extraction from acidified samples (viscera) or by deproteinization (blood, plasma) with methanol before HPLC analysis. Postmortem concentrations of 2,4-D in body fluids and tissues are given. The proposed method resulted in a rapid procedure most useful in cases of deliberate poisoning with phenoxyacetic herbicides.

  16. Transcatheter Arterial Embolization as a Treatment for Medial Knee Pain in Patients with Mild to Moderate Osteoarthritis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Okuno, Yuji, E-mail: how-lowlow@yahoo.co.jp; Korchi, Amine Mohamed, E-mail: amine.korchi@gmail.com; Shinjo, Takuma, E-mail: shin.takuma@a7.keio.jp

    PurposeOsteoarthritis is a common cause of pain and disability. Mild to moderate knee osteoarthritis that is resistant to nonsurgical options and not severe enough to warrant joint replacement represents a challenge in its management. On the basis of the hypothesis that neovessels and accompanying nerves are possible sources of pain, previous work demonstrated that transcatheter arterial embolization for chronic painful conditions resulted in excellent pain relief. We hypothesized that transcatheter arterial embolization can relieve pain associated with knee osteoarthritis.MethodsTranscatheter arterial embolization for mild to moderate knee osteoarthritis using imipenem/cilastatin sodium or 75 μm calibrated Embozene microspheres as an embolic agent hasmore » been performed in 11 and three patients, respectively. We assessed adverse events and changes in Western Ontario and McMaster University Osteoarthritis Index (WOMAC) scores.ResultsAbnormal neovessels were identified within soft tissue surrounding knee joint in all cases by arteriography. No major adverse events were related to the procedures. Transcatheter arterial embolization rapidly improved WOMAC pain scores from 12.2 ± 1.9 to 3.3 ± 2.1 at 1 month after the procedure, with further improvement at 4 months (1.7 ± 2.2) and WOMAC total scores from 47.3 ± 5.8 to 11.6 ± 5.4 at 1 month, and to 6.3 ± 6.0 at 4 months. These improvements were maintained in most cases at the final follow-up examination at a mean of 12 ± 5 months (range 4–19 months).ConclusionTranscatheter arterial embolization for mild to moderate knee osteoarthritis was feasible, rapidly relieved resistant pain, and restored knee function.« less

  17. Prosthetic valve endocarditis 7 months after transcatheter aortic valve implantation diagnosed with 3D TEE.

    PubMed

    Sarı, Cenk; Durmaz, Tahir; Karaduman, Bilge Duran; Keleş, Telat; Bayram, Hüseyin; Baştuğ, Serdal; Özen, Mehmet Burak; Bayram, Nihal Akar; Bilen, Emine; Ayhan, Hüseyin; Kasapkara, Hacı Ahmet; Bozkurt, Engin

    2016-01-01

    Transcatheter aortic valve implantation (TAVI) was introduced as an alternative treatment for patients with severe symptomatic aortic stenosis for whom surgery would be high-risk. Prosthetic aortic valve endocarditis is a serious complication of surgical AVR (SAVR) with high morbidity and mortality. According to recent cases, post-TAVI prosthetic valve endocarditis (PVE) seems to occur very rarely. We present the case of a 75-year-old woman who underwent TAVI (Edwards Saphien XT) with an uneventful postoperative stay. She was diagnosed with endocarditis using three dimensional (3D) echocardiography on the TAVI device 7 months later and she subsequently underwent surgical aortic valve replacement. Little experience of the interpretation of transoesophageal echocardiography (TEE) and the clinical course and effectiveness of treatment strategies in post-TAVI endocarditis exists. We report a case of PVE in a TAVI patient which was diagnosed with three-dimensional transoesophageal echocardiography (3DTEE). Copyright © 2016 Hellenic Cardiological Society. Published by Elsevier B.V. All rights reserved.

  18. Cost comparison of transcatheter and operative closures of ostium secundum atrial septal defects

    PubMed Central

    O’Byrne, Michael L.; Gillespie, Matthew J.; Shinohara, Russell T.; Dori, Yoav; Rome, Jonathan J.; Glatz, Andrew C.

    2015-01-01

    Background Clinical outcomes for transcatheter and operative closures of atrial septal defects (ASDs) are similar. Economic cost for each method has not been well described. Methods A single-center retrospective cohort study of children and adults <30 years of age undergoing closure for single secundum ASD from January 1, 2007, to April 1, 2012, was performed to measure differences in inflation-adjusted cost of operative and transcatheter closures of ASD. A propensity score weight-adjusted multivariate regression model was used in an intention-to-treat analysis. Costs for reintervention and crossover admissions were included in primary analysis. Results A total of 244 subjects were included in the study (64% transcatheter and 36% operative), of which 2% (n = 5) were ≥18 years. Crossover rate from transcatheter to operative group was 3%. Risk of reintervention (P = .66) and 30-day mortality (P = .37) were not significantly different. In a multivariate model, adjusted cost of operative closure was 2012 US $60,992 versus 2012 US $55,841 for transcatheter closure (P < .001). Components of total cost favoring transcatheter closure were length of stay, medications, and follow-up radiologic and laboratory testing, overcoming higher costs of procedure and echocardiography. Professional costs did not differ. The rate of 30-day readmission was greater in the operative cohort, further increasing the cost advantage of transcatheter closure. Sensitivity analyses demonstrated that costs of follow-up visits influenced relative cost but that device closure remained favorable over a broad range of crossover and reintervention rates. Conclusion For single secundum ASD, cost comparison analysis favors transcatheter closure over the short term. The cost of follow-up regimens influences the cost advantage of transcatheter closure. PMID:25965721

  19. [Initial experience of transcatheter implantation with a new aortic valve in sheep].

    PubMed

    Wang, Jian-ming; Yang, Jian; Yang, Li-fang; Zhang, Xue-xin; Hu, Yun; Liu, Jin-cheng; Yu, Shi-qiang; Yi, Ding-hua

    2011-11-01

    To evaluate the feasibility and short-term results of transcatheter aortic valve implantation (TAVI) using a new transcatheter valve. Twenty healthy adult sheep received general anesthesia. Under the guidance of X-ray and transthoracic echocardiography (TTE), the new anti-calcification transcatheter valve was released from delivery system and implanted at the level of native aortic annulus via left common carotid artery. Position and function of the new anti-calcification transcatheter valve were evaluated by angiography and TTE immediately after intervention. Thirty day survival rate of animals was obtained. New transcatheter valves were implanted in all sheep. Fifteen sheep (75%) survived up to 30 days and post-operative examination showed that the transcatheter valve was in optimal position without migration and mitral valve impingement. The native coronary artery was patent in these animals. There was a slight paravalvular leak in 5 sheep. Postoperative echocardiography showed reflux percentage was significantly increased (P < 0.05) compared pre-intervention. Effective orifice area, aortic systolic pressure, diastolic aortic pressure, mean aortic pressure, left ventricular systolic pressure, left ventricular end diastolic pressure and heart rate were similar between post and pre-intervention (all P < 0.05). Five sheep died after TAVI within 30 days, including one fatal ventricular fibrillation occurred immediately after releasing the transcatheter valve and another sheep died of acute myocardial infarction due to left main coronary artery occlusion evidenced by angiography. Two sheep died of severe mitral regurgitation at 8 and 12 hours post-operation and one died of infective endocarditis at 26 days after intervention. Our favorable preliminary results showed that it was feasible to perform TAVI using the new transcatheter valve.

  20. Safety and efficacy of minimalist approach in transfemoral transcatheter aortic valve replacement: insights from the Optimized transCathEter vAlvular interventioN-Transcatheter Aortic Valve Implantation (OCEAN-TAVI) registry.

    PubMed

    Hosoba, Soh; Yamamoto, Masanori; Shioda, Kayoko; Sago, Mitsuru; Koyama, Yutaka; Shimura, Tetsuro; Kagase, Ai; Tada, Norio; Naganuma, Toru; Araki, Motoharu; Yamanaka, Futoshi; Shirai, Shinichi; Watanabe, Yusuke; Hayashida, Kentaro

    2018-03-01

    Favourable results have been reported for monitored anaesthesia care that includes local anaesthesia and conscious sedation [minimalist approach (MA)] for transfemoral transcatheter aortic valve replacement (TAVR). However, the efficacy of MA is still controversial in Japan. We describe our experience from a Japanese multicentre registry. Between October 2013 and April 2016, 1215 consecutive Japanese patients with symptomatic, severe aortic stenosis undergoing TAVR with self-expandable or balloon-expandable valves were prospectively included in the Optimized transCathEter vAlvular intervention-Transcatheter Aortic Valve Implantation (OCEAN-TAVI) registry. Of these patients, we retrospectively reviewed 921 consecutive patients who underwent elective transfemoral-TAVR. We evaluated the perioperative results of MA-TAVR and non-minimalist approach (NMA) TAVR using propensity score matching analysis. A total of 118 patients underwent MA-TAVR, and 802 patients underwent NMA-TAVR [median age 84 vs 85 years, P = 0.25; Society of Thoracic Surgeons (STS) score 7.6 vs 6.4, P = 0.01]. One hundred eighteen matched pairs were compared after propensity score matching. In-hospital mortality and stroke/transient ischaemic attack were not significantly different between the MA-TAVR and the NMA-TAVR groups (2.5% vs 0.8%, P = 0.3; 1.7% vs 0.8%, P = 0.6, respectively). Major or life-threatening bleeding and the transfusion rate were significantly lower in the MA-TAVR group (3.4% vs 17%, P = 0.003; 6.8% vs 29%, P = 0.0002, respectively). The total intensive care unit days and length of hospital stay were significantly lower in the MA-TAVR group (P ≤ 0.0002). MA-TAVR has similar results to NMA-TAVR in terms of mortality and stroke in this Japanese multicentre registry. Shorter procedure time and hospital stays were seen in the MA-TAVR group. MA-TAVR is as safe and effective as NMA-TAVR. © The Author 2017. Published by Oxford University Press on behalf of

  1. A Leadless Intracardiac Transcatheter Pacing System.

    PubMed

    Reynolds, Dwight; Duray, Gabor Z; Omar, Razali; Soejima, Kyoko; Neuzil, Petr; Zhang, Shu; Narasimhan, Calambur; Steinwender, Clemens; Brugada, Josep; Lloyd, Michael; Roberts, Paul R; Sagi, Venkata; Hummel, John; Bongiorni, Maria Grazia; Knops, Reinoud E; Ellis, Christopher R; Gornick, Charles C; Bernabei, Matthew A; Laager, Verla; Stromberg, Kurt; Williams, Eric R; Hudnall, J Harrison; Ritter, Philippe

    2016-02-11

    A leadless intracardiac transcatheter pacing system has been designed to avoid the need for a pacemaker pocket and transvenous lead. In a prospective multicenter study without controls, a transcatheter pacemaker was implanted in patients who had guideline-based indications for ventricular pacing. The analysis of the primary end points began when 300 patients reached 6 months of follow-up. The primary safety end point was freedom from system-related or procedure-related major complications. The primary efficacy end point was the percentage of patients with low and stable pacing capture thresholds at 6 months (≤2.0 V at a pulse width of 0.24 msec and an increase of ≤1.5 V from the time of implantation). The safety and efficacy end points were evaluated against performance goals (based on historical data) of 83% and 80%, respectively. We also performed a post hoc analysis in which the rates of major complications were compared with those in a control cohort of 2667 patients with transvenous pacemakers from six previously published studies. The device was successfully implanted in 719 of 725 patients (99.2%). The Kaplan-Meier estimate of the rate of the primary safety end point was 96.0% (95% confidence interval [CI], 93.9 to 97.3; P<0.001 for the comparison with the safety performance goal of 83%); there were 28 major complications in 25 of 725 patients, and no dislodgements. The rate of the primary efficacy end point was 98.3% (95% CI, 96.1 to 99.5; P<0.001 for the comparison with the efficacy performance goal of 80%) among 292 of 297 patients with paired 6-month data. Although there were 28 major complications in 25 patients, patients with transcatheter pacemakers had significantly fewer major complications than did the control patients (hazard ratio, 0.49; 95% CI, 0.33 to 0.75; P=0.001). In this historical comparison study, the transcatheter pacemaker met the prespecified safety and efficacy goals; it had a safety profile similar to that of a transvenous system

  2. The Economics of Transcatheter Valve Interventions.

    PubMed

    Sud, Maneesh; Tam, Derrick Y; Wijeysundera, Harindra C

    2017-09-01

    A subset of patients who require correction of a stenotic or incompetent valve are deemed to be at excessive surgical risk, which precludes surgical repair or replacement. Transcatheter valve interventions are viable alternatives in these patients. However, these technologies are costly, and in the setting of a constrained Canadian health care budget, economic value is an important consideration to allow for fair allocation of scarce resources. Accordingly, we review the economic literature on transcatheter valve interventions, targeting a general audience. Our specific goals are highlighting how best to interpret these studies and discuss the implications of these technologies on the Canadian health care system. Transcatheter aortic valve replacement (TAVR) is a cost-effective alternative for inoperable patients who otherwise would receive medical therapy. When compared with surgical aortic valve replacement (SAVR), TAVR is associated with significant reductions in postprocedure hospital resource use, which offsets the substantially higher cost of the TAVR valve system relative to SAVR valves. Although cost-effectiveness estimates for TAVR in high-risk operable candidates vary widely across studies, based on contemporary data from the perspective of the Canadian health care system, TAVR is likely to provide economic value. Recent studies suggest that when compared with medical therapy for severe degenerative mitral regurgitation, the MitraClip (Abbott, Abbott Park, IL) may offer economic value in high-risk patients; however, in the absence of randomized controlled trials, this is speculative. Nonetheless, these transcatheter technologies represent a paradigm shift in the management of valvular disease; their dissemination will have substantial impact in cardiovascular care delivery. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  3. Transcatheter JenaValve Implantation in a Stentless Prosthesis: A Challenging Case After 4 Previous Aortic Procedures.

    PubMed

    Sponga, Sandro; Mazzaro, Enzo; Bagur, Rodrigo; Livi, Ugolino

    2017-04-01

    A 40-year-old man underwent 4 aortic surgeries because of endocarditis and subsequent prosthesis dehiscence. At the last recurrence he presented with acute severe aortic regurgitation of a Pericarbon Freedom (LivaNova plc, London, UK) stentless bioprosthesis and a morphologically disarranged aortic root. He also presented with left ventricular dysfunction and a very low origin of the left coronary artery. Therefore, a fifth redo aortic valve replacement was considered at high surgical risk. Accordingly, before listing the patient for a heart transplantation, a transcatheter valve-in-valve implantation with the JenaValve (JenaValve Technology, GmbH, Munich, Germany) prosthesis was performed. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  4. Transcatheter Coil Embolization of Splenic Artery Aneurysm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamamoto, Satoshi, E-mail: s-yama@hyo-med.ac.jp; Hirota, Shozo; Maeda, Hiroaki

    2008-05-15

    The purpose of this study was to evaluate clinical results and technical problems of transcatheter coil embolization for splenic artery aneurysm. Subjects were 16 patients (8 men, 8 women; age range, 40-80 years) who underwent transcatheter embolization for splenic artery aneurysm (14 true aneurysms, 2 false aneurysms) at one of our hospitals during the period January 1997 through July 2005. Two aneurysms (12.5%) were diagnosed at the time of rupture. Multiple splenic aneurysms were found in seven patients. Aneurysms were classified by site as proximal (or strictly ostial) (n = 3), middle (n = 3), or hilar (n = 10).more » The indication for transcatheter arterial embolization was a false or true aneurysm 20 mm in diameter. Embolic materials were fibered coils and interlocking detachable coils. Embolization was performed by the isolation technique, the packing technique, or both. Technically, all aneurysms were devascularized without severe complications. Embolized aneurysms were 6-40 mm in diameter (mean, 25 mm). Overall, the primary technical success rate was 88% (14 of 16 patients). In the remaining 2 patients (12.5%), partial recanalization occurred, and re-embolization was performed. The secondary technical success rate was 100%. Seven (44%) of the 16 study patients suffered partial splenic infarction. Intrasplenic branching originating from the aneurysm was observed in five patients. We conclude that transcatheter coil embolization should be the initial treatment of choice for splenic artery aneurysm.« less

  5. Gait Speed Predicts 30-Day Mortality After Transcatheter Aortic Valve Replacement: Results From the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry.

    PubMed

    Alfredsson, Joakim; Stebbins, Amanda; Brennan, J Matthew; Matsouaka, Roland; Afilalo, Jonathan; Peterson, Eric D; Vemulapalli, Sreekanth; Rumsfeld, John S; Shahian, David; Mack, Michael J; Alexander, Karen P

    2016-04-05

    Surgical risk scores do not include frailty assessments (eg, gait speed), which are of particular importance for patients with severe aortic stenosis considering transcatheter aortic valve replacement. We assessed the association of 5-m gait speed with outcomes in a cohort of 8039 patients who underwent transcatheter aortic valve replacement (November 2011-June 2014) and were included in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. We evaluated the association between continuous and categorical gait speed and 30-day all-cause mortality before and after adjustment for Society of Thoracic Surgeons-predicted risk of mortality score and key variables. Secondary outcomes included in-hospital mortality, bleeding, acute kidney injury, and stroke. The overall median gait speed was 0.63 m/s (25th-75th percentile, 0.47-0.79 m/s), with the slowest walkers (<0.5 m/s) constituting 28%, slow walkers (0.5-0.83 m/s) making up 48%, and normal walkers (>0.83 m/s) constituting 24% of the population. Thirty-day all-cause mortality rates were 8.4%, 6.6%, and 5.4% for the slowest, slow, and normal walkers, respectively (P<0.001). Each 0.2-m/s decrease in gait speed corresponded to an 11% increase in 30-day mortality (adjusted odds ratio, 1.11; 95% confidence interval, 1.01-1.22). The slowest walkers had 35% higher 30-day mortality than normal walkers (adjusted odds ratio, 1.35; 95% confidence interval, 1.01-1.80), significantly longer hospital stays, and a lower probability of being discharged to home. Gait speed is independently associated with 30-day mortality after transcatheter aortic valve replacement. Identification of frail patients with the slowest gait speeds facilitates preprocedural evaluation and anticipation of a higher level of postprocedural care. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01737528. © 2016 American Heart Association, Inc.

  6. Simultaneous transcatheter treatment of perimembranous ventricular septal defect and other congenital cardiopathies.

    PubMed

    Xu, Xu-Dong; Bai, Yuan; Chen, Xiao-Li; Liu, Su-Xuan; Zhao, Xian-Xian; Qin, Yong-Wen

    2014-12-01

    To assess the efficacy and safety of simultaneous transcatheter corrections of perimembranous ventricular septal defect (VSD) and other congenital cardiopathies. From 2004 to 2012, 56 patients (25 male, 31 female), aged 14.2±10.1, with compound congenital cardiovascular abnormalities underwent simultaneous transcatheter interventional procedure. Of the 56 patients, 32 had VSD and atrial septal defects (ASD); 17 had VSD and patent ductus arteriosus (PDA); and seven had VSD and pulmonary valve stenosis (PS). Percutaneous balloon pulmonary valvuloplasty (PBPV) was performed before the closure of VSD, PDA, or ASD. The combined transcatheter interventional procedure was successfully performed in all patients. Among these, two occluders were implanted in each of 49 patients, seven patients with VSD combined with PS underwent successfully balloon valvuloplasty and VSD closure. The size of VSD, ASD and PDA detected by TTE was 4.8±1.7 mm, 9.0±5.0 mm and 4.5±2.5 mm, respectively. The occluder diameter of VSD, ASD and PDA was 7.6±2.2 mm, 14.3±6.2 mm and 7.9±3.2 mm, respectively. The peak-to-peak transpulmonary gradient decreased from 60.4±19.7 mmHg to 15.0±5.0 mmHg (p<0.001) in seven patients with VSD combined with PS. One patient with VSD and ASD had a permanent pacemaker implanted because of third-degree atrioventricular block two months after the procedure. There were not serious adverse events in relation to the combined procedures during the 23.8±20.7 months of follow-up in other 55 patients. The simultaneous treatment of VSD and other congenital cardiopathies using transcatheter-based procedures is safe and effective, which can provide satisfactory results. Copyright © 2014 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  7. Impact of CT attenuation correction method on quantitative respiratory-correlated (4D) PET/CT imaging

    PubMed Central

    Lee, Tzu-Cheng; Alessio, Adam M.; Wollenweber, Scott D.; Stearns, Charles W.; Bowen, Stephen R.; Kinahan, Paul E.

    2015-01-01

    Purpose: Respiratory-correlated positron emission tomography (PET/CT) 4D PET/CT is used to mitigate errors from respiratory motion; however, the optimal CT attenuation correction (CTAC) method for 4D PET/CT is unknown. The authors performed a phantom study to evaluate the quantitative performance of CTAC methods for 4D PET/CT in the ground truth setting. Methods: A programmable respiratory motion phantom with a custom movable insert designed to emulate a lung lesion and lung tissue was used for this study. The insert was driven by one of five waveforms: two sinusoidal waveforms or three patient-specific respiratory waveforms. 3DPET and 4DPET images of the phantom under motion were acquired and reconstructed with six CTAC methods: helical breath-hold (3DHEL), helical free-breathing (3DMOT), 4D phase-averaged (4DAVG), 4D maximum intensity projection (4DMIP), 4D phase-matched (4DMATCH), and 4D end-exhale (4DEXH) CTAC. Recovery of SUVmax, SUVmean, SUVpeak, and segmented tumor volume was evaluated as RCmax, RCmean, RCpeak, and RCvol, representing percent difference relative to the static ground truth case. Paired Wilcoxon tests and Kruskal–Wallis ANOVA were used to test for significant differences. Results: For 4DPET imaging, the maximum intensity projection CTAC produced significantly more accurate recovery coefficients than all other CTAC methods (p < 0.0001 over all metrics). Over all motion waveforms, ratios of 4DMIP CTAC recovery were 0.2 ± 5.4, −1.8 ± 6.5, −3.2 ± 5.0, and 3.0 ± 5.9 for RCmax, RCpeak, RCmean, and RCvol. In comparison, recovery coefficients for phase-matched CTAC were −8.4 ± 5.3, −10.5 ± 6.2, −7.6 ± 5.0, and −13.0 ± 7.7 for RCmax, RCpeak, RCmean, and RCvol. When testing differences between phases over all CTAC methods and waveforms, end-exhale phases were significantly more accurate (p = 0.005). However, these differences were driven by the patient-specific respiratory waveforms; when testing patient and sinusoidal waveforms

  8. Transcatheter mitral valve repair in osteogenesis imperfecta associated mitral valve regurgitation.

    PubMed

    van der Kley, Frank; Delgado, Victoria; Ajmone Marsan, Nina; Schalij, Martin J

    2014-08-01

    Osteogenesis imperfecta is associated with increased prevalence of significant mitral valve regurgitation. Surgical mitral valve repair and replacement are feasible but are associated with increased risk of bleeding and dehiscence of implanted valves may occur more frequently. The present case report describes the outcomes of transcatheter mitral valve repair in a patient with osteogenesis imperfecta. A 60 year-old patient with osteogenesis imperfecta and associated symptomatic moderate to severe mitral regurgitation underwent transthoracic echocardiography which showed a nondilated left ventricle with preserved systolic function and moderate to severe mitral regurgitation. On transoesophageal echocardiography the regurgitant jet originated between the anterolateral scallops of the anterior and posterior leaflets (A1-P1). Considering the comorbidities associated with osteogenesis imperfecta the patient was accepted for transcatheter mitral valve repair using the Mitraclip device (Abbott vascular, Menlo, CA). Under fluoroscopy and 3D transoesophageal echocardiography guidance, a Mitraclip device was implanted between the anterolateral and central scallops with significant reduction of mitral regurgitation. The postoperative evolution was uneventful. At one month follow-up, transthoracic echocardiography showed a stable position of the Mitraclip device with no mitral regurgitation. Transcatheter mitral valve repair is feasible and safe in patients with osteogenesis imperfecta and associated symptomatic significant mitral regurgitation. Copyright © 2014 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  9. Intraoperative three-dimensional transesophageal echocardiography for assessing the defect geometries of mitral prosthetic paravalvular leak during transcatheter closure.

    PubMed

    Wei, Jeng; Yin, Wei-Hsian; Lee, Yung-Tsai; Hsiung, Ming C; Tsai, Shen-Kou; Chuang, Yi Cheng; Ou, Ching-Huei; Chou, Yi-Pen

    2015-03-01

    Paravalvular leaks (PVLs) are a common complication of prosthetic valve replacement. Use of the transcatheter intervention technique is a suitable alternative in high-risk patients who may not tolerate repeat surgery. Common reasons for failure of this demanding intervention include poor imaging quality and unsuitable anatomy. The purpose of this study was to assess the usefulness and the incremental value of real-time three-dimensional (RT 3D) transesophageal echocardiography (TEE) over two-dimensional (2D) TEE findings in the evaluation of the geometry and track of mitral PVLs during transcatheter closure. Five patients with six mitral PVLs at high risk for repeat surgery underwent transcatheter leak closure. Intraoperative RT 3DTEE was used to assess the location, shape, number, and size of the defects. Transapical approaches were used in all cases with fluoroscopic and RT 3D TEE guidance of the wire and catheter, device positioning, and assessment of residual leak after the procedure. In all of the cases, defects with irregular crescent shapes and distorted tracks were clearly delineated by RT 3D TEE. This was compared to those results obtained through 2D TEE, which was unable to characterize the defects. Three cases showed small leaks, which were completely occluded with a patent ductus arteriosus (PDA) device in two cases, and a muscular ventricular septal defect (mVSD) occluder combined with coil devices in one case. One case involved a large leak and early device embolization of the muscular VSD occluder, which was removed surgically, and demonstrated a crescent-shaped defect. One patient had two releaks 2 months subsequent to the procedure due to two new extended leaks at the tails of the crescent-shaped defect. RT 3D TEE can clearly delineate the geometries of defects in their entirety, including shape, size, and location of the defect and track canal. It would also appear that RT 3D TEE is superior to 2D TEE in the process of guiding the wire through the

  10. Objective Measurement of Arterial Flow Before and After Transcatheter Arterial Chemoembolization: A Feasibility Study Using Quantitative Color-Coding Analysis.

    PubMed

    Lin, Yi-Yang; Lee, Rheun-Chuan; Tseng, Hsiuo-Shan; Liu, Chien-An; Guo, Wan-Yuo; Chang, Cheng-Yen

    2015-12-01

    To quantitatively measure the hemodynamic change of hepatic artery before and after transcatheter arterial chemoembolization (TACE) of hepatocellular carcinoma (HCC) by quantitative color-coding analysis (QCA). This prospective study registered 64 consecutive HCC patients who underwent segmental or subsegmental TACE with epirubicin and lipiodol at level 2 or 3 of the subjective angiographic chemoembolization endpoint. QCA was used to determine the maximal density time (T(max)) of selected intravascular region of interest (ROI). Relative T(max) (rT(max)) was defined as the T(max) at the selected ROI minus the time of contrast medium spurting from the catheter tip. The rT(max) of hepatic arteries was analyzed before and after embolization. The pre- and post-treatment rT(max) of the landmarks at the treated segmental artery were 1.96 ± 0.48 and 3.14 ± 1.77 s, p < 0.001. According to the treated lobe, 30 patients were treated for the right lobe alone, and 8 patients were treated for the left lobe alone. The pre- and post-rT(max) of treated segmental artery were 2.06 ± 0.54, 3.34 ± 1.63 s, p < 0.001 and 1.89 ± 0.45, 2.68 ± 1.46 s, p = 0.12, respectively. The rT(max) of the proximal lobar hepatic arteries or proper hepatic artery had no significant change before and after TACE. The QCA is feasible to quantify embolization endpoints by comparing the rT(max) in selected hepatic arteries before and after TACE. The rT(max) of treated segmental artery was significant prolonged after optimized procedures.

  11. 3D printing based on cardiac CT assists anatomic visualization prior to transcatheter aortic valve replacement.

    PubMed

    Ripley, Beth; Kelil, Tatiana; Cheezum, Michael K; Goncalves, Alexandra; Di Carli, Marcelo F; Rybicki, Frank J; Steigner, Mike; Mitsouras, Dimitrios; Blankstein, Ron

    2016-01-01

    3D printing is a promising technique that may have applications in medicine, and there is expanding interest in the use of patient-specific 3D models to guide surgical interventions. To determine the feasibility of using cardiac CT to print individual models of the aortic root complex for transcatheter aortic valve replacement (TAVR) planning as well as to determine the ability to predict paravalvular aortic regurgitation (PAR). This retrospective study included 16 patients (9 with PAR identified on blinded interpretation of post-procedure trans-thoracic echocardiography and 7 age, sex, and valve size-matched controls with no PAR). 3D printed models of the aortic root were created from pre-TAVR cardiac computed tomography data. These models were fitted with printed valves and predictions regarding post-implant PAR were made using a light transmission test. Aortic root 3D models were highly accurate, with excellent agreement between annulus measurements made on 3D models and those made on corresponding 2D data (mean difference of -0.34 mm, 95% limits of agreement: ± 1.3 mm). The 3D printed valve models were within 0.1 mm of their designed dimensions. Examination of the fit of valves within patient-specific aortic root models correctly predicted PAR in 6 of 9 patients (6 true positive, 3 false negative) and absence of PAR in 5 of 7 patients (5 true negative, 2 false positive). Pre-TAVR 3D-printing based on cardiac CT provides a unique patient-specific method to assess the physical interplay of the aortic root and implanted valves. With additional optimization, 3D models may complement traditional techniques used for predicting which patients are more likely to develop PAR. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  12. 3D Printing Based on Cardiac CT Assists Anatomic Visualization Prior to Transcatheter Aortic Valve Replacement

    PubMed Central

    Ripley, Beth; Kelil, Tatiana; Cheezum, Michael K.; Goncalves, Alexandra; Di Carli, Marcelo F.; Rybicki, Frank J.; Steigner, Mike; Mitsouras, Dimitrios; Blankstein, Ron

    2017-01-01

    Background 3D printing is a promising technique that may have applications in medicine, and there is expanding interest in the use of patient-specific 3D models to guide surgical interventions. Objective To determine the feasibility of using cardiac CT to print individual models of the aortic root complex for transcatheter aortic valve replacement (TAVR) planning as well as to determine the ability to predict paravalvular aortic regurgitation (PAR). Methods This retrospective study included 16 patients (9 with PAR identified on blinded interpretation of post-procedure trans-thoracic echocardiography and 7 age, sex, and valve size-matched controls with no PAR). 3D printed models of the aortic root were created from pre-TAVR cardiac computed tomography data. These models were fitted with printed valves and predictions regarding post-implant PAR were made using a light transmission test. Results Aortic root 3D models were highly accurate, with excellent agreement between annulus measurements made on 3D models and those made on corresponding 2D data (mean difference of −0.34 mm, 95% limits of agreement: ± 1.3 mm). The 3D printed valve models were within 0.1 mm of their designed dimensions. Examination of the fit of valves within patient-specific aortic root models correctly predicted PAR in 6 of 9 patients (6 true positive, 3 false negative) and absence of PAR in 5 of 7 patients (5 true negative, 2 false positive). Conclusions Pre-TAVR 3D-printing based on cardiac CT provides a unique patient-specific method to assess the physical interplay of the aortic root and implanted valves. With additional optimization, 3D models may complement traditional techniques used for predicting which patients are more likely to develop PAR. PMID:26732862

  13. Thrombogenic potential of transcatheter aortic valve implantation with trivial paravalvular leakage

    PubMed Central

    Siegel, Rolland

    2014-01-01

    Background Significant paravalvular leakage after transcatheter aortic valve implantation (TAVI) correlates with increased morbidity and mortality, but adverse consequences of trivial paravalvular leakage have stimulated few investigations. Using a unique method distinctly different from other diagnostic approaches, we previously reported elevated backflow velocities of short duration (transients) in mechanical valve closure. In this study, similar transients were found in a transcatheter valve paravalvular leakage avatar. Methods Paravalvular leakage rate (zero to 58 mL/second) and aortic valve incompetence (volumetric back flow/forward flow; zero to 32%) were made adjustable using a mock transcatheter aortic valve device and tested in quasi-steady and pulsatile flow test systems. Projected dynamic valve area (PDVA) from the back illuminated mock transcatheter aortic valve device was measured and regional backflow velocities were derived by dividing volumetric flow rate by the PDVA over the open and closing valve phase and the total closed valve area derived from backflow leakage. Results Aortic incompetence from 1-32% generated negative backflow transients from 8 to 267 meters/second, a range not dissimilar to that measured in mechanical valves with zero paravalvular leakage. Optimal paravalvular leakage was identified; not too small generating high backflow transients, not too large considering volume overload and cardiac energy loss caused by defective valve behavior and fluid motion. Conclusions Thrombogenic potential of transcatheter aortic valves with trivial aortic incompetence and high magnitude regional backflow velocity transients was comparable to mechanical valves. This may have relevance to stroke rate, asymptomatic microembolic episodes and indications for anticoagulation therapy after transcatheter valve insertion. PMID:25333018

  14. Transcatheter closure of large patent ductus arteriosus using custom made devices.

    PubMed

    Rohit, Manoj Kumar; Gupta, Ankur

    2017-05-01

    There has been a paradigm shift in the transcatheter closure of patent ductus arteriosus (PDA) over the last 45 years. With the availability of various coils, plugs and occluders, PDA of almost all shapes and sizes are amenable to transcatheter closure. However, very large PDA diagnosed late in life are being referred for surgical closure in the absence of availability of large size devices, especially in developing countries. In this case series, we have described four patients with large PDA, three of which were closed by transcatheter custom made PDA occluders. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.

  15. Multi-physics 3D computational study of leaflet thrombus formation following surgical and transcatheter aortic valve replacement

    NASA Astrophysics Data System (ADS)

    Vahidkhah, Koohyar; Abbasi, Mostafa; Barakat, Mohammed; Dvir, Danny; Azadani, Ali

    2017-11-01

    An increasingly recognized complication following surgical/transcatheter aortic valve replacement is thrombosis or blood clot formation on replacement valve leaflets. A predisposing factor in thrombus formation on biomaterial surfaces of a bioprosthetic heart valve is blood stasis. Longer residence time of blood provides an opportunity for platelets and agonists to accumulate to critical concentrations that leads to platelet activation and then thrombosis. In this study, we have developed a fluid-solid interaction (FSI) modeling approach, to quantify blood stasis on the leaflets of bioprosthetic aortic valves with different design operating in a patient-specific geometry. We have validated our FSI model against experimental measurements of valve opening/closing as well as in-vitro particle image velocimetry. We have also embedded in our method a model for transport of platelets and agonists (ADP, TxA2, and thrombin) and their interactions that result in platelets activation and adhesion to biomaterial bioprosthetic surfaces. We have provided quantitative evidence for the correlation between long residence of blood on bioprosthetic aortic valve leaflets and formation of high thrombogenicity risk regions on the leaflets that are characterized by accumulation of activated platelet.

  16. The Melody® valve and Ensemble® delivery system for transcatheter pulmonary valve replacement

    PubMed Central

    McElhinney, Doff B; Hennesen, Jill T

    2013-01-01

    The Melody® transcatheter pulmonary valve (TPV) is a percutaneous valve system designed for the treatment of obstruction and/or regurgitation of prosthetic conduits placed between the right ventricle and pulmonary arteries in patients with congenital heart disease. In 2000, Melody TPV became the first transcatheter valve implanted in a human; in 2006 it became the first transcatheter valve commercially available anywhere in the world; and in 2010 it was launched as the first commercially available transcatheter valve in the United States. In this review, we present the clinical background against which the Melody valve was developed and implemented, introduce the rationale for and challenges of transcatheter valve technology for this population, outline the history and technical details of its development and use, and summarize currently available data concerning the performance of the device. PMID:23834411

  17. Impact of CT attenuation correction method on quantitative respiratory-correlated (4D) PET/CT imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nyflot, Matthew J., E-mail: nyflot@uw.edu; Lee, Tzu-Cheng; Alessio, Adam M.

    Purpose: Respiratory-correlated positron emission tomography (PET/CT) 4D PET/CT is used to mitigate errors from respiratory motion; however, the optimal CT attenuation correction (CTAC) method for 4D PET/CT is unknown. The authors performed a phantom study to evaluate the quantitative performance of CTAC methods for 4D PET/CT in the ground truth setting. Methods: A programmable respiratory motion phantom with a custom movable insert designed to emulate a lung lesion and lung tissue was used for this study. The insert was driven by one of five waveforms: two sinusoidal waveforms or three patient-specific respiratory waveforms. 3DPET and 4DPET images of the phantommore » under motion were acquired and reconstructed with six CTAC methods: helical breath-hold (3DHEL), helical free-breathing (3DMOT), 4D phase-averaged (4DAVG), 4D maximum intensity projection (4DMIP), 4D phase-matched (4DMATCH), and 4D end-exhale (4DEXH) CTAC. Recovery of SUV{sub max}, SUV{sub mean}, SUV{sub peak}, and segmented tumor volume was evaluated as RC{sub max}, RC{sub mean}, RC{sub peak}, and RC{sub vol}, representing percent difference relative to the static ground truth case. Paired Wilcoxon tests and Kruskal–Wallis ANOVA were used to test for significant differences. Results: For 4DPET imaging, the maximum intensity projection CTAC produced significantly more accurate recovery coefficients than all other CTAC methods (p < 0.0001 over all metrics). Over all motion waveforms, ratios of 4DMIP CTAC recovery were 0.2 ± 5.4, −1.8 ± 6.5, −3.2 ± 5.0, and 3.0 ± 5.9 for RC{sub max}, RC{sub peak}, RC{sub mean}, and RC{sub vol}. In comparison, recovery coefficients for phase-matched CTAC were −8.4 ± 5.3, −10.5 ± 6.2, −7.6 ± 5.0, and −13.0 ± 7.7 for RC{sub max}, RC{sub peak}, RC{sub mean}, and RC{sub vol}. When testing differences between phases over all CTAC methods and waveforms, end-exhale phases were significantly more accurate (p = 0.005). However, these differences were

  18. An augmented magnetic navigation system for Transcatheter Aortic Valve Implantation.

    PubMed

    Luo, Zhe; Cai, Junfeng; Nie, Yuanyuan; Wang, Guotai; Gu, Lixu

    2013-01-01

    This research proposes an augmented magnetic navigation system for Transcatheter Aortic Valve Implantation (TAVI) employing a magnetic tracking system (MTS) combined with a dynamic aortic model and intra-operative ultrasound (US) images. The dynamic 3D aortic model is constructed based on the preoperative 4D computed tomography (CT), which is animated according to the real time electrocardiograph (ECG) input of patient. And a preoperative planning is performed to determine the target position of the aortic valve prosthesis. The temporal alignment is performed to synchronize the ECG signals, intra-operative US image and tracking information. Afterwards, with the assistance of synchronized ECG signals, the contour of aortic root automatic extracted from short axis US image is registered to the dynamic aortic model by a feature based registration intra-operatively. Then the augmented MTS guides the interventionist to confidently position and deploy the aortic valve prosthesis to target. The system was validated by animal studies on three porcine subjects, the deployment and tilting errors of which are 3.17 ± 0.91 mm and 7.40 ± 2.89° respectively.

  19. Transcatheter arterial embolization for upper gastrointestinal tract bleeding

    PubMed Central

    Širvinskas, Audrius; Smolskas, Edgaras; Brimienė, Vilma; Brimas, Gintautas

    2017-01-01

    Introduction Transcatheter arterial embolization is a possible treatment for patients with recurrent bleeding from the upper gastrointestinal tract after failed endoscopic management and is also an alternative to surgical treatment. Aim To analyze the outcomes of transcatheter arterial embolization and identify the clinical and technical factors that influenced the rates of morbidity and mortality. Material and methods A retrospective analysis was carried out, based on the data of 36 patients who underwent transcatheter arterial embolization for acute nonvariceal upper gastrointestinal bleeding in 2013 to 2015 in our center. An analysis was performed between early rebleeding rates, mortality and the following factors: patient sex, age, number of units of packed red blood cells and packed plasma administered to the patients, length of hospital stay, therapeutic or prophylactic embolization. Results The technical success rate of the embolization procedure was 100%. There were 15 (41.70%) therapeutic embolizations and 21 (58.3%) prophylactic embolizations. There was a 77.8% clinical success rate. Following embolization, 10 (27.80%) patients had repeated bleeding and 9 (25.0%) patients died. Significant associations were found between rebleeding and prophylactic embolization (OR = 10.53; p = 0.04) and between mortality and prophylactic embolization (OR = 10.53; p = 0.04) and units of packed red blood cells (OR = 1.25; p < 0.01). Conclusions In our experience, transcatheter arterial embolization is a safe treatment method for acute nonvariceal upper gastrointestinal bleeding and a possible alternative to surgery for high-risk patients. PMID:29362654

  20. 1-Year Outcomes After Transcatheter Aortic Valve Replacement With Balloon-Expandable Versus Self-Expandable Valves: Results From the CHOICE Randomized Clinical Trial.

    PubMed

    Abdel-Wahab, Mohamed; Neumann, Franz-Josef; Mehilli, Julinda; Frerker, Christian; Richardt, Doreen; Landt, Martin; Jose, John; Toelg, Ralph; Kuck, Karl-Heinz; Massberg, Steffen; Robinson, Derek R; El-Mawardy, Mohamed; Richardt, Gert

    2015-08-18

    The use of a balloon-expandable transcatheter heart valve previously resulted in a greater rate of device success compared with a self-expandable transcatheter heart valve. The aim of this study was to evaluate clinical and echocardiographic outcome data at longer term follow-up. The investigator-initiated trial randomized 241 high-risk patients with symptomatic severe aortic stenosis and anatomy suitable for treatment with both balloon- and self-expandable transcatheter heart valves to transfemoral transcatheter aortic valve replacement with either device. Patients were followed-up for 1 year, with assessment of clinical outcomes and echocardiographic evaluation of valve function. At 1 year, the rates of death of any cause (17.4% vs. 12.8%; relative risk [RR]: 1.35; 95% confidence interval [CI]: 0.73 to 2.50; p = 0.37) and of cardiovascular causes (12.4% vs. 9.4%; RR: 1.32; 95% CI: 0.63 to 2.75; p = 0.54) were not statistically significantly different in the balloon- and self-expandable groups, respectively. The frequencies of all strokes (9.1% vs. 3.4%; RR: 2.66; 95% CI: 0.87 to 8.12; p = 0.11) and repeat hospitalization for heart failure (7.4% vs. 12.8%; RR: 0.58; 95% CI: 0.26 to 1.27; p = 0.19) did not statistically significantly differ between the 2 groups. Elevated transvalvular gradients during follow-up were observed in 4 patients in the balloon-expandable group (3.4% vs. 0%; p = 0.12); all were resolved with anticoagulant therapy, suggesting a thrombotic etiology. More than mild paravalvular regurgitation was more frequent in the self-expandable group (1.1% vs. 12.1%; p = 0.005). Despite the higher device success rate with the balloon-expandable valve, 1-year follow-up of patients in CHOICE (Randomized Comparison of Transcatheter Heart Valves in High Risk Patients With Severe Aortic Stenosis: Medtronic CoreValve Versus Edwards SAPIEN XT Trial), with limited statistical power, revealed clinical outcomes after transfemoral transcatheter aortic valve

  1. Quantitative LC-MS Provides No Evidence for m6 dA or m4 dC in the Genome of Mouse Embryonic Stem Cells and Tissues.

    PubMed

    Schiffers, Sarah; Ebert, Charlotte; Rahimoff, René; Kosmatchev, Olesea; Steinbacher, Jessica; Bohne, Alexandra-Viola; Spada, Fabio; Michalakis, Stylianos; Nickelsen, Jörg; Müller, Markus; Carell, Thomas

    2017-09-04

    Until recently, it was believed that the genomes of higher organisms contain, in addition to the four canonical DNA bases, only 5-methyl-dC (m 5 dC) as a modified base to control epigenetic processes. In recent years, this view has changed dramatically with the discovery of 5-hydroxymethyl-dC (hmdC), 5-formyl-dC (fdC), and 5-carboxy-dC (cadC) in DNA from stem cells and brain tissue. N 6 -methyldeoxyadenosine (m 6 dA) is the most recent base reported to be present in the genome of various eukaryotic organisms. This base, together with N 4 -methyldeoxycytidine (m 4 dC), was first reported to be a component of bacterial genomes. In this work, we investigated the levels and distribution of these potentially epigenetically relevant DNA bases by using a novel ultrasensitive UHPLC-MS method. We further report quantitative data for m 5 dC, hmdC, fdC, and cadC, but we were unable to detect either m 4 dC or m 6 dA in DNA isolated from mouse embryonic stem cells or brain and liver tissue, which calls into question their epigenetic relevance. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Transcatheter closure of a sinus venosus atrial septal defect using 3D printing and image fusion guidance.

    PubMed

    Thakkar, Akanksha N; Chinnadurai, Ponraj; Breinholt, John P; Lin, C Huie

    2018-06-13

    A 63-year-old man with cirrhosis, hepatocellular carcinoma, and coagulopathy was diagnosed with a sinus venosus atrial septal defect (ASD) and partial anomalous pulmonary venous return (PAPVR) of the right upper pulmonary vein (RUPV). Transcatheter repair by positioning a stent graft in the superior vena cava was planned. Based on three-dimensional (3D) reconstruction of gated cardiac CTA, a 28 mm × 7 cm Endurant II ® aortic extension stent graft (Medtronic, MN) was chosen. A 3D model printed from the CTA was used to simulate device deployment, demonstrating successful exclusion of the sinus venosus ASD with return of the RUPV to the left atrium (LA). Post simulation, the 3D model was used for informed consent. The patient was then taken to the hybrid operating room. On-table cone beam CT was performed and registered with the CTA images. This enabled overlay of 3D regions of interest to live 2D fluoroscopy. The stent graft was then deployed using 3D regions of interest for guidance. Hemodynamics and angiography demonstrated successful exclusion of the sinus venosus ASD and unobstructed return of RUPV to the LA. This is the first report of comprehensive use of contemporary imaging for planning, simulation, patient consent, and procedural guidance for patient-centered complex structural intervention in repair of sinus venosus ASD with PAPVR. We propose this as a process model for continued innovation in structural interventions. © 2018 The Authors Catheterization and Cardiovascular Interventions Published by Wiley Periodicals, Inc.

  3. In vitro evaluation of flow patterns and turbulent kinetic energy in trans-catheter aortic valve prostheses.

    PubMed

    Giese, Daniel; Weiss, Kilian; Baeßler, Bettina; Madershahian, Navid; Choi, Yeong-Hoon; Maintz, David; Bunck, Alexander C

    2018-02-01

    The objective of the current work was to evaluate flow and turbulent kinetic energy in different transcatheter aortic valve implants using highly undersampled time-resolved multi-point 3-directional phase-contrast measurements (4D Flow MRI) in an in vitro setup. A pulsatile flow setup was used with a compliant tubing mimicking a stiff left ventricular outflow tract and ascending aorta. Five different implants were measured using a highly undersampled multi-point 4D Flow MRI sequence. Velocities and turbulent kinetic energy values were analysed and compared. Strong variations of turbulent kinetic energy distributions between the valves were observed. Maximum turbulent kinetic energy values ranged from 100 to over 500 J/m 3 while through-plane velocities were similar between all valves. Highly accelerated 4D Flow MRI for the measurement of velocities and turbulent kinetic energy values allowed for the assessment of hemodynamic parameters in five different implant models. The presented setup, measurement protocol and analysis methods provides an efficient approach to compare different valve implants and could aid future novel valve designs.

  4. 3D Printed Cardiac Phantom for Procedural Planning of a Transcatheter Native Mitral Valve Replacement

    PubMed Central

    Izzo, Richard L.; O’Hara, Ryan P.; Iyer, Vijay; Hansen, Rose; Meess, Karen M.; Nagesh, S.V. Setlur; Rudin, Stephen; Siddiqui, Adnan H.; Springer, Michael; Ionita, Ciprian N.

    2017-01-01

    3D printing an anatomically accurate, functional flow loop phantom of a patient’s cardiac vasculature was used to assist in the surgical planning of one of the first native transcatheter mitral valve replacement (TMVR) procedures. CTA scans were acquired from a patient about to undergo the first minimally-invasive native TMVR procedure at the Gates Vascular Institute in Buffalo, NY. A python scripting library, the Vascular Modeling Toolkit (VMTK), was used to segment the 3D geometry of the patient’s cardiac chambers and mitral valve with severe stenosis, calcific in nature. A stereolithographic (STL) mesh was generated and AutoDesk Meshmixer was used to transform the vascular surface into a functioning closed flow loop. A Stratasys Objet 500 Connex3 multi-material printer was used to fabricate the phantom with distinguishable material features of the vasculature and calcified valve. The interventional team performed a mock procedure on the phantom, embedding valve cages in the model and imaging the phantom with a Toshiba Infinix INFX-8000V 5-axis C-arm bi-Plane angiography system. Results After performing the mock-procedure on the cardiac phantom, the cardiologists optimized their transapical surgical approach. The mitral valve stenosis and calcification were clearly visible. The phantom was used to inform the sizing of the valve to be implanted. Conclusion With advances in image processing and 3D printing technology, it is possible to create realistic patient-specific phantoms which can act as a guide for the interventional team. Using 3D printed phantoms as a valve sizing method shows potential as a more informative technique than typical CTA reconstruction alone. PMID:28615797

  5. 3D Printed Cardiac Phantom for Procedural Planning of a Transcatheter Native Mitral Valve Replacement.

    PubMed

    Izzo, Richard L; O'Hara, Ryan P; Iyer, Vijay; Hansen, Rose; Meess, Karen M; Nagesh, S V Setlur; Rudin, Stephen; Siddiqui, Adnan H; Springer, Michael; Ionita, Ciprian N

    2016-02-27

    3D printing an anatomically accurate, functional flow loop phantom of a patient's cardiac vasculature was used to assist in the surgical planning of one of the first native transcatheter mitral valve replacement (TMVR) procedures. CTA scans were acquired from a patient about to undergo the first minimally-invasive native TMVR procedure at the Gates Vascular Institute in Buffalo, NY. A python scripting library, the Vascular Modeling Toolkit (VMTK), was used to segment the 3D geometry of the patient's cardiac chambers and mitral valve with severe stenosis, calcific in nature. A stereolithographic (STL) mesh was generated and AutoDesk Meshmixer was used to transform the vascular surface into a functioning closed flow loop. A Stratasys Objet 500 Connex3 multi-material printer was used to fabricate the phantom with distinguishable material features of the vasculature and calcified valve. The interventional team performed a mock procedure on the phantom, embedding valve cages in the model and imaging the phantom with a Toshiba Infinix INFX-8000V 5-axis C-arm bi-Plane angiography system. After performing the mock-procedure on the cardiac phantom, the cardiologists optimized their transapical surgical approach. The mitral valve stenosis and calcification were clearly visible. The phantom was used to inform the sizing of the valve to be implanted. With advances in image processing and 3D printing technology, it is possible to create realistic patient-specific phantoms which can act as a guide for the interventional team. Using 3D printed phantoms as a valve sizing method shows potential as a more informative technique than typical CTA reconstruction alone.

  6. 3D printed cardiac phantom for procedural planning of a transcatheter native mitral valve replacement

    NASA Astrophysics Data System (ADS)

    Izzo, Richard L.; O'Hara, Ryan P.; Iyer, Vijay; Hansen, Rose; Meess, Karen M.; Nagesh, S. V. Setlur; Rudin, Stephen; Siddiqui, Adnan H.; Springer, Michael; Ionita, Ciprian N.

    2016-03-01

    3D printing an anatomically accurate, functional flow loop phantom of a patient's cardiac vasculature was used to assist in the surgical planning of one of the first native transcatheter mitral valve replacement (TMVR) procedures. CTA scans were acquired from a patient about to undergo the first minimally-invasive native TMVR procedure at the Gates Vascular Institute in Buffalo, NY. A python scripting library, the Vascular Modeling Toolkit (VMTK), was used to segment the 3D geometry of the patient's cardiac chambers and mitral valve with severe stenosis, calcific in nature. A stereolithographic (STL) mesh was generated and AutoDesk Meshmixer was used to transform the vascular surface into a functioning closed flow loop. A Stratasys Objet 500 Connex3 multi-material printer was used to fabricate the phantom with distinguishable material features of the vasculature and calcified valve. The interventional team performed a mock procedure on the phantom, embedding valve cages in the model and imaging the phantom with a Toshiba Infinix INFX-8000V 5-axis Carm bi-Plane angiography system. Results: After performing the mock-procedure on the cardiac phantom, the cardiologists optimized their transapical surgical approach. The mitral valve stenosis and calcification were clearly visible. The phantom was used to inform the sizing of the valve to be implanted. Conclusion: With advances in image processing and 3D printing technology, it is possible to create realistic patientspecific phantoms which can act as a guide for the interventional team. Using 3D printed phantoms as a valve sizing method shows potential as a more informative technique than typical CTA reconstruction alone.

  7. Transcatheter closure of ventricular septal defect with Occlutech Duct Occluder.

    PubMed

    Atik-Ugan, Sezen; Saltik, Irfan Levent

    2018-04-01

    Patent ductus arteriosus occluders are used for transcatheter closure of ventricular septal defects, as well as for closure of patent ductus arteriosus. The Occlutech Duct Occluder is a newly introduced device for transcatheter closure of patent ductus arteriosus. Here, we present a case in which the Occlutech Duct Occluder was successfully used on a patient for the closure of a perimembraneous ventricular septal defect.

  8. Radiation exposure in transcatheter patent ductus arteriosus closure: time to tune?

    PubMed

    Villemain, Olivier; Malekzadeh-Milani, Sophie; Sitefane, Fidelio; Mostefa-Kara, Meriem; Boudjemline, Younes

    2018-05-01

    The aims of this study were to describe radiation level at our institution during transcatheter patent ductus arteriosus occlusion and to evaluate the components contributing to radiation exposure. Transcatheter occlusion relying on X-ray imaging has become the treatment of choice for patients with patent ductus arteriosus. Interventionists now work hard to minimise radiation exposure in order to reduce risk of induced cancers. We retrospectively reviewed all consecutive children who underwent transcatheter closure of patent ductus arteriosus from January 2012 to January 2016. Clinical data, anatomical characteristics, and catheterisation procedure parameters were reported. Radiation doses were analysed for the following variables: total air kerma, mGy; dose area product, Gy.cm2; dose area product per body weight, Gy.cm2/kg; and total fluoroscopic time. A total of 324 patients were included (median age=1.51 [Q1-Q3: 0.62-4.23] years; weight=10.3 [6.7-17.0] kg). In all, 322/324 (99.4%) procedures were successful. The median radiation doses were as follows: total air kerma: 26 (14.5-49.3) mGy; dose area product: 1.01 (0.56-2.24) Gy.cm2; dose area product/kg: 0.106 (0.061-0.185) Gy.cm2/kg; and fluoroscopic time: 2.8 (2-4) min. In multivariate analysis, a weight >10 kg, a ductus arteriosus width <2 mm, complications during the procedure, and a high frame rate (15 frames/second) were risk factors for an increased exposure. Lower doses of radiation can be achieved with subsequent recommendations: technical improvement, frame rate reduction, avoidance of biplane cineangiograms, use of stored fluoroscopy as much as possible, and limitation of fluoroscopic time. A greater use of echocardiography might even lessen the exposure.

  9. Prospective ECG-triggered, axial 4-D imaging of the aortic root, valvular, and left ventricular structures: a lower radiation dose option for preprocedural TAVR imaging.

    PubMed

    Bolen, Michael A; Popovic, Zoran B; Dahiya, Arun; Kapadia, Samir R; Tuzcu, E Murat; Flamm, Scott D; Halliburton, Sandra S; Schoenhagen, Paul

    2012-01-01

    Transcatheter valve interventions rely on imaging for patient selection, preprocedural planning, and intraprocedural guidance. We explored the use of prospective electrocardiogram (ECG)-triggered 4-dimensional (4-D) CT imaging in patients evaluated for transcatheter aortic valve replacement (TAVR). A total of 47 consecutive patients underwent 128-slice dual-source CT with wide-window dose-modulated prospective ECG-triggered, axial acquisition of the aortic root, reconstructed during diastolic and systolic cardiac phases. Image quality was evaluated, aortic root and left ventricular (LV) geometry and function were analyzed, and radiation exposure was estimated. Image quality was generally good, with 41 of 47 (87%) patients scored as good or excellent. The mean aortic valve area was 0.93 ± 0.24 cm(2). Mean LV ejection fraction was 56.8% ± 16.4%, and mean LV mass was 130.4 ± 43.8 g. The minor diameter of the annulus was larger in systole (systole, 2.29 ± 0.24 cm; diastole, 2.14 ± 0.25 cm; P = 0.006), but the mean and major diameters did not vary significantly between systole and diastole. The mean estimated effective dose was 5.9 ± 2.4 mSv. Multiphase, prospective ECG-triggered axial image acquisition is a lower dose acquisition technique for 4-D aortic root imaging in patients being considered for TAVR. Copyright © 2012 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  10. Mortality Risk After Transcatheter Aortic Valve Implantation: Analysis of the Predictive Accuracy of the Transcatheter Valve Therapy Registry Risk Assessment Model.

    PubMed

    Codner, Pablo; Malick, Waqas; Kouz, Remi; Patel, Amisha; Chen, Cheng-Han; Terre, Juan; Landes, Uri; Vahl, Torsten Peter; George, Isaac; Nazif, Tamim; Kirtane, Ajay J; Khalique, Omar K; Hahn, Rebecca T; Leon, Martin B; Kodali, Susheel

    2018-05-08

    Risk assessment tools currently used to predict mortality in transcatheter aortic valve implantation (TAVI) were designed for patients undergoing cardiac surgery. We aim to assess the accuracy of the TAVI dedicated American College of Cardiology / Transcatheter Valve Therapies (ACC/TVT) risk score in predicting mortality outcomes. Consecutive patients (n=1038) undergoing TAVI at a single institution from 2014 to 2016 were included. The ACC/TVT registry mortality risk score, the Society of Thoracic Surgeons - Patient Reported Outcomes (STS-PROM) score and the EuroSCORE II were calculated for all patients. In hospital and 30-day all-cause mortality rates were 1.3% and 2.9%, respectively. The ACC/TVT risk stratification tool scored higher for patients who died in-hospital than in those who survived the index hospitalization (6.4 ± 4.6 vs. 3.5 ± 1.6, p = 0.03; respectively). The ACC/TVT score showed a high level of discrimination, C-index for in-hospital mortality 0.74, 95% CI [0.59 - 0.88]. There were no significant differences between the performance of the ACC/TVT registry risk score, the EuroSCORE II and the STS-PROM for in hospital and 30-day mortality rates. The ACC/TVT registry risk model is a dedicated tool to aid in the prediction of in-hospital mortality risk after TAVI.

  11. Quantitative analysis of the patellofemoral motion pattern using semi-automatic processing of 4D CT data.

    PubMed

    Forsberg, Daniel; Lindblom, Maria; Quick, Petter; Gauffin, Håkan

    2016-09-01

    To present a semi-automatic method with minimal user interaction for quantitative analysis of the patellofemoral motion pattern. 4D CT data capturing the patellofemoral motion pattern of a continuous flexion and extension were collected for five patients prone to patellar luxation both pre- and post-surgically. For the proposed method, an observer would place landmarks in a single 3D volume, which then are automatically propagated to the other volumes in a time sequence. From the landmarks in each volume, the measures patellar displacement, patellar tilt and angle between femur and tibia were computed. Evaluation of the observer variability showed the proposed semi-automatic method to be favorable over a fully manual counterpart, with an observer variability of approximately 1.5[Formula: see text] for the angle between femur and tibia, 1.5 mm for the patellar displacement, and 4.0[Formula: see text]-5.0[Formula: see text] for the patellar tilt. The proposed method showed that surgery reduced the patellar displacement and tilt at maximum extension with approximately 10-15 mm and 15[Formula: see text]-20[Formula: see text] for three patients but with less evident differences for two of the patients. A semi-automatic method suitable for quantification of the patellofemoral motion pattern as captured by 4D CT data has been presented. Its observer variability is on par with that of other methods but with the distinct advantage to support continuous motions during the image acquisition.

  12. Elevation of B-Type Natriuretic Peptide at Discharge is Associated With 2-Year Mortality After Transcatheter Aortic Valve Replacement in Patients With Severe Aortic Stenosis: Insights From a Multicenter Prospective OCEAN-TAVI (Optimized Transcatheter Valvular Intervention-Transcatheter Aortic Valve Implantation) Registry.

    PubMed

    Mizutani, Kazuki; Hara, Masahiko; Iwata, Shinichi; Murakami, Takashi; Shibata, Toshihiko; Yoshiyama, Minoru; Naganuma, Toru; Yamanaka, Futoshi; Higashimori, Akihiro; Tada, Norio; Takagi, Kensuke; Araki, Motoharu; Ueno, Hiroshi; Tabata, Minoru; Shirai, Shinichi; Watanabe, Yusuke; Yamamoto, Masanori; Hayashida, Kentaro

    2017-07-14

    In this study, we sought to investigate the 2-year prognostic impact of B-type natriuretic peptide (BNP) levels at discharge, following transcatheter aortic valve replacement. We enrolled 1094 consecutive patients who underwent transcatheter aortic valve replacement between 2013 and 2016. Study patients were stratified into 2 groups according to survival classification and regression tree analysis (high versus low BNP groups). We evaluated the impact of high BNP on 2-year mortality compared with that of low BNP using a multivariable Cox model, and assessed whether this stratification would improve predictive accuracy for determining 2-year mortality by assessing time-dependent net reclassification improvement and integrated discrimination improvement. The median age of patients was 85 years (quartile 82-88), and 29.2% of the study population were men. The median Society of Thoracic Surgeons score was 6.8 (4.7-9.5), and BNP at discharge was 186 (93-378) pg/mL. All-cause mortality following discharge was 7.9% (95% CI, 5.8-9.9%) at 1 year and 15.4% (95% CI, 11.6-19.0%) at 2 years. The survival classification and regression tree analysis revealed that the discriminating BNP level to discern 2-year mortality was 202 pg/mL, and that elevated BNP had a statistically significant impact on outcomes, with an adjusted hazard ratio of 2.28 (1.36-3.82, P =0.002). The time-dependent net reclassification improvement ( P =0.047) and integrated discrimination improvement ( P =0.029) analysis revealed that the incorporation of BNP stratification with other clinical variables significantly improved predictive accuracy for 2-year mortality. Elevation of BNP at discharge is associated with 2-year mortality after transcatheter aortic valve replacement. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  13. Transcatheter Embolotherapy with N-Butyl Cyanoacrylate for Ectopic Varices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, Jin Woo; Kim, Hyo-Cheol, E-mail: angiointervention@gmail.com; Jae, Hwan Jun, E-mail: jaemdphd@gmail.com

    PurposeTo address technical feasibility and clinical outcome of transcatheter embolotherapy with N-butyl cyanoacrylate (NBCA) for bleeding ectopic varices.MethodsThe institutional review board approved this retrospective study and waived informed consent. From January 2004 to June 2013, a total of 12 consecutive patients received transcatheter embolotherapy using NBCA for bleeding ectopic varices in our institute. Clinical and radiologic features of the endovascular procedures were comprehensively reviewed.ResultsPreprocedural computed tomography images revealed ectopic varices in the jejunum (n = 7), stoma (n = 2), rectum (n = 2), and duodenum (n = 1). The 12 procedures consisted of solitary embolotherapy (n = 8) and embolotherapy with portal decompression (main portal vein stenting in 3,more » transjugular intrahepatic portosystemic shunt in 1). With regard to vascular access, percutaneous transhepatic access (n = 7), transsplenic access (n = 4), and transjugular intrahepatic portosystemic shunt tract (n = 1) were used. There was no failure in either the embolotherapy or the vascular accesses (technical success rate, 100 %). Two patients died within 1 month from the procedure from preexisting fatal medical conditions. Only one patient, with a large varix that had been partially embolized by using coils and NBCA, underwent rebleeding 5.5 months after the procedure. The patient was retreated with NBCA and did not undergo any bleeding afterward for a follow-up period of 2.5 months. The remaining nine patients did not experience rebleeding during the follow-up periods (range 1.5–33.2 months).ConclusionTranscatheter embolotherapy using NBCA can be a useful option for bleeding ectopic varices.« less

  14. Longitudinal Hemodynamics of Transcatheter and Surgical Aortic Valves in the PARTNER Trial.

    PubMed

    Douglas, Pamela S; Leon, Martin B; Mack, Michael J; Svensson, Lars G; Webb, John G; Hahn, Rebecca T; Pibarot, Philippe; Weissman, Neil J; Miller, D Craig; Kapadia, Samir; Herrmann, Howard C; Kodali, Susheel K; Makkar, Raj R; Thourani, Vinod H; Lerakis, Stamatios; Lowry, Ashley M; Rajeswaran, Jeevanantham; Finn, Matthew T; Alu, Maria C; Smith, Craig R; Blackstone, Eugene H

    2017-11-01

    Use of transcatheter aortic valve replacement (TAVR) for severe aortic stenosis is growing rapidly. However, to our knowledge, the durability of these prostheses is incompletely defined. To determine the midterm hemodynamic performance of balloon-expandable transcatheter heart valves. In this study, we analyzed core laboratory-generated data from echocardiograms of all patients enrolled in the Placement of Aortic Transcatheter Valves (PARTNER) 1 Trial with successful TAVR or surgical AVR (SAVR) obtained preimplantation and at 7 days, 1 and 6 months, and 1, 2, 3, 4, and 5 years postimplantation. Patients from continued access observational studies were included for comparison. Successful implantation after randomization to TAVR vs SAVR (PARTNER 1A; TAVR, n = 321; SAVR, n = 313), TAVR vs medical treatment (PARTNER 1B; TAVR, n = 165), and continued access (TAVR, n = 1996). Five-year echocardiogram data were available for 424 patients after TAVR and 49 after SAVR. Death or reintervention for aortic valve structural indications, measured using aortic valve mean gradient, effective orifice area, Doppler velocity index, and evidence of hemodynamic deterioration by reintervention, adverse hemodynamics, or transvalvular regurgitation. Of 2795 included patients, the mean (SD) age was 84.5 (7.1) years, and 1313 (47.0%) were female. Population hemodynamic trends derived from nonlinear mixed-effects models showed small early favorable changes in the first few months post-TAVR, with a decrease of -2.9 mm Hg in aortic valve mean gradient, an increase of 0.028 in Doppler velocity index, and an increase of 0.09 cm2 in effective orifice area. There was relative stability at a median follow-up of 3.1 (maximum, 5) years. Moderate/severe transvalvular regurgitation was noted in 89 patients (3.7%) after TAVR and increased over time. Patients with SAVR showed no significant changes. In TAVR, death/reintervention was associated with lower ejection fraction, stroke volume

  15. Neurofibromatosis Type 1: Transcatheter Arterial Embolization for Ruptured Occipital Arterial Aneurysms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kanematsu, Masayuki; Kato, Hiroki; Kondo, Hiroshi

    Two cases of ruptured aneurysms in the posterior cervical regions associated with type-1 neurofibromatosis treated by transcatheter embolization are reported. Patients presented with acute onset of swelling and pain in the affected areas. Emergently performed contrast-enhanced CT demonstrated aneurysms and large hematomas widespread in the posterior cervical regions. Angiography revealed aneurysms and extravasations of the occipital artery. Patients were successfully treated by percutaneous transcatheter arterial microcoil embolization. Transcatheter arterial embolization therapy was found to be an effective method for treating aneurysmal rupture in the posterior cervical regions occurring in association with type-1 neurofibromatosis. A literature review revealed that rupture ofmore » an occipital arterial aneurysm, in the setting of neurofibromatosis type 1, has not been reported previously.« less

  16. 3D echocardiographic analysis of aortic annulus for transcatheter aortic valve replacement using novel aortic valve quantification software: Comparison with computed tomography.

    PubMed

    Mediratta, Anuj; Addetia, Karima; Medvedofsky, Diego; Schneider, Robert J; Kruse, Eric; Shah, Atman P; Nathan, Sandeep; Paul, Jonathan D; Blair, John E; Ota, Takeyoshi; Balkhy, Husam H; Patel, Amit R; Mor-Avi, Victor; Lang, Roberto M

    2017-05-01

    With the increasing use of transcatheter aortic valve replacement (TAVR) in patients with aortic stenosis (AS), computed tomography (CT) remains the standard for annulus sizing. However, 3D transesophageal echocardiography (TEE) has been an alternative in patients with contraindications to CT. We sought to (1) test the feasibility, accuracy, and reproducibility of prototype 3DTEE analysis software (Philips) for aortic annular measurements and (2) compare the new approach to the existing echocardiographic techniques. We prospectively studied 52 patients who underwent gated contrast CT, procedural 3DTEE, and TAVR. 3DTEE images were analyzed using novel semi-automated software designed for 3D measurements of the aortic root, which uses multiplanar reconstruction, similar to CT analysis. Aortic annulus measurements included area, perimeter, and diameter calculations from these measurements. The results were compared to CT-derived values. Additionally, 3D echocardiographic measurements (3D planimetry and mitral valve analysis software adapted for the aortic valve) were also compared to the CT reference values. 3DTEE image quality was sufficient in 90% of patients for aortic annulus measurements using the new software, which were in good agreement with CT (r-values: .89-.91) and small (<4%) inter-modality nonsignificant biases. Repeated measurements showed <10% measurements variability. The new 3D analysis was the more accurate and reproducible of the existing echocardiographic techniques. Novel semi-automated 3DTEE analysis software can accurately measure aortic annulus in patients with severe AS undergoing TAVR, in better agreement with CT than the existing methodology. Accordingly, intra-procedural TEE could potentially replace CT in patients where CT carries significant risk. © 2017, Wiley Periodicals, Inc.

  17. Transcatheter valve-in-valve therapy using 6 different devices in 4 anatomic positions: Clinical outcomes and technical considerations.

    PubMed

    Conradi, Lenard; Silaschi, Miriam; Seiffert, Moritz; Lubos, Edith; Blankenberg, Stefan; Reichenspurner, Hermann; Schaefer, Ulrich; Treede, Hendrik

    2015-12-01

    Transcatheter valve-in-valve implantation (ViV) is emerging as a novel treatment option for patients with deteriorated bioprostheses. We report our cumulative experience using 6 types of transcatheter heart valves (THVs) in all anatomic positions. Seventy-five consecutive patients (74.1 ± 12.9 years, 50.7% male (38/75), logEuroSCORE I 26.2% ± 17.8%, STS-PROM 8.8% ± 7.4%) receiving ViV procedures from 2008 to 2014 were included for analysis. Data were prospectively gathered and retrospectively analyzed. ViV was performed in aortic (72.0%, 54/75), mitral (22.7%, 17/75), tricuspid (2.7%, 2/75), and pulmonary (2.7%, 2/75) positions. THVs used were Edwards SAPIEN (XT)/SAPIEN3 (52.0%, 39/75), Medtronic Core Valve/Core Valve Evolut(R) (34.7%, 26/75), St Jude Portico (4.0%, 3/75), Boston Scientific Lotus (4.0%, 3/75), Jena Valve (2.7%, 2/75), and Medtronic Engager (2.7%, 2/75). Interval from index procedure to ViV was 9.3 ± 4.9 years. Access was transapical in 53.3% (40/75), transfemoral (transarterial or transvenous) in 42.7% (32/75), transaortic in 2.7% (2/75), and transjugular in 1.3% (1/75). ViV was successful in 97.3% (73/75) with 2 patients requiring sequential THV implantation for initial malpositioning. Overall immediate procedural (≤72 hours) and all-cause 30-day mortality were 2.7% (2/75) and 8.0% (6/75). Corresponding values after aortic ViV were 1.9% (1/54) and 5.6% (3/54). No periprocedural strokes or cases of coronary obstruction occurred. Paravalvular leakage was less than or equal to mild in all cases. After aortic ViV, gradients were max/mean 34.1 ± 14.2/20.1 ± 7.1 mm Hg and effective orifice area (EOA) was 1.5 ± 1.4 cm(2). Corresponding values after mitral ViV were gradients max/mean 14.2 ± 8.2/4.7 ± 3.1 mm Hg and EOA 2.4 ± 0.9 cm(2). ViV can be performed in all anatomic positions with acceptable hemodynamic and clinical outcome in high-risk patients. Increasing importance of ViV can be anticipated considering growing use of surgical

  18. Transfemoral transcatheter aortic valve insertion-related intraoperative morbidity: Implications of the minimalist approach.

    PubMed

    Greason, Kevin L; Pochettino, Alberto; Sandhu, Gurpreet S; King, Katherine S; Holmes, David R

    2016-04-01

    Transfemoral transcatheter aortic valve insertion may be performed in a catheterization laboratory (ie, the minimalist approach). It seems reasonable when considering this approach to avoid it in patients at risk for intraoperative morbidity that would require surgical intervention. We hypothesized that it would be possible to associate baseline characteristics with such morbidity, which would help heart teams select patients for the minimalist approach. We reviewed the records of 215 consecutive patients who underwent transfemoral transcatheter aortic valve insertion with a current commercially available device from November 2008 through July 2015. Demographic characteristics of the patients included a mean age of 78.9 ± 10.6 years, female sex in 73 patients (34.0%), and a mean Society of Thoracic Surgeons predicted risk of mortality of 8.7% ± 5.4%. Valve prostheses were balloon-expandable in 126 patients (58.6%) and self-expanding in 89 patients (41.4%). Significant intraoperative morbidity occurred in 22 patients (10.2%) and included major vascular injury in 12 patients (5.6%), hemodynamic compromise requiring cardiopulmonary bypass support in 4 patients (1.9%), cardiac tamponade requiring intervention in 3 patients (1.4%), ventricular valve embolization in 2 patients (0.9%), and inability to obtain percutaneous access requiring open vascular access in 1 patient (0.5%). Intraoperative morbidity was similarly distributed across all valve types (P = .556) and sheath sizes (P = .369). There were no baseline patient characteristics predictive of intraoperative morbidity. Patient and valve characteristics are not predictive of significant intraoperative morbidity during transfemoral transcatheter aortic valve insertion. The finding has implications for patient selection for the minimalist approach. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  19. Transcatheter aortic valve implantation and cerebrovascular accidents.

    PubMed

    Stortecky, Stefan; Wenaweser, Peter; Windecker, Stephan

    2012-09-01

    Transcatheter aortic valve implantation (TAVI) is an evidence-based treatment alternative for selected high-risk patients with symptomatic severe aortic stenosis as acknowledged in the most recent edition of the ESC Guidelines on Valvular Heart Disease 2012. However, periprocedural complications and in particular cerebrovascular accidents remain a matter of concern. While transcatheter heart valve technology continuously improves and the development of novel and even less invasive implantation techniques is on-going, cerebrovascular events complicating TAVI may abrogate the usual improvement in terms of prognosis and quality of life. This article describes the incidence of cerebrovascular events after cardiovascular procedures, provides an overview of the pathophysiological mechanisms as well as the impact on outcomes and provides some insights into preventive strategies as well as the acute management of these events.

  20. Prevalence and Prognostic Significance of Right Ventricular Systolic Dysfunction in Patients Undergoing Transcatheter Aortic Valve Implantation.

    PubMed

    Lindsay, Alistair C; Harron, Katie; Jabbour, Richard J; Kanyal, Ritesh; Snow, Thomas M; Sawhney, Paramvir; Alpendurada, Francisco; Roughton, Michael; Pennell, Dudley J; Duncan, Alison; Di Mario, Carlo; Davies, Simon W; Mohiaddin, Raad H; Moat, Neil E

    2016-07-01

    Cardiovascular magnetic resonance (CMR) can provide important structural information in patients undergoing transcatheter aortic valve implantation. Although CMR is considered the standard of reference for measuring ventricular volumes and mass, the relationship between CMR findings of right ventricular (RV) function and outcomes after transcatheter aortic valve implantation has not previously been reported. A total of 190 patients underwent 1.5 Tesla CMR before transcatheter aortic valve implantation. Steady-state free precession sequences were used for aortic valve planimetry and to assess ventricular volumes and mass. Semiautomated image analysis was performed by 2 specialist reviewers blinded to patient treatment. Patient follow-up was obtained from the Office of National Statistics mortality database. The median age was 81.0 (interquartile range, 74.9-85.5) years; 50.0% were women. Impaired RV function (RV ejection fraction ≤50%) was present in 45 (23.7%) patients. Patients with RV dysfunction had poorer left ventricular ejection fractions (42% versus 69%), higher indexed left ventricular end-systolic volumes (96 versus 40 mL), and greater indexed left ventricular mass (101 versus 85 g/m(2); P<0.01 for all) than those with normal RV function. Median follow-up was 850 days; 21 of 45 (46.7%) patients with RV dysfunction died, compared with 43 of 145 (29.7%) patients with normal RV function (P=0.035). After adjustment for significant baseline variables, both RV ejection fraction ≤50% (hazard ratio, 2.12; P=0.017) and indexed aortic valve area (hazard ratio, 4.16; P=0.025) were independently associated with survival. RV function, measured on preprocedural CMR, is an independent predictor of mortality after transcatheter aortic valve implantation. CMR assessment of RV function may be important in the risk stratification of patients undergoing transcatheter aortic valve implantation. © 2016 American Heart Association, Inc.

  1. Transcatheter Closure of Patent Foramen Ovale: Devices and Technique.

    PubMed

    Price, Matthew J

    2017-10-01

    Transcatheter closure of a patent foramen ovale (PFO) reduces the risk of recurrent cryptogenic stroke compared with medical therapy. PFO closure is a prophylactic procedure, and will not provide the patient with symptomatic improvement, except in cases of hypoxemia due to right-to-left shunt or possibly migraine headaches. Therefore, appropriate patient selection is critical, and procedural safety is paramount. Herein, we review key characteristics of the devices currently available for transcatheter PFO closure within the United States, and highlight key technical aspects of the PFO closure procedure that will maximize procedural success. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Transcatheter Aortic Valve-in-Valve Procedure in Patients with Bioprosthetic Structural Valve Deterioration

    PubMed Central

    Reul, Ross M.; Ramchandani, Mahesh K.; Reardon, Michael J.

    2017-01-01

    Surgical aortic valve replacement is the gold standard procedure to treat patients with severe, symptomatic aortic valve stenosis or insufficiency. Bioprosthetic valves are used for surgical aortic valve replacement with a much greater prevalence than mechanical valves. However, bioprosthetic valves may fail over time because of structural valve deterioration; this often requires intervention due to severe bioprosthetic valve stenosis or regurgitation or a combination of both. In select patients, transcatheter aortic valve replacement is an alternative to surgical aortic valve replacement. Transcatheter valve-in-valve (ViV) replacement is performed by implanting a transcatheter heart valve within a failing bioprosthetic valve. The transcatheter ViV operation is a less invasive procedure compared with reoperative surgical aortic valve replacement, but it has been associated with specific complications and requires extensive preoperative work-up and planning by the heart team. Data from experimental studies and analyses of results from clinical procedures have led to strategies to improve outcomes of these procedures. The type, size, and implant position of the transcatheter valve can be optimized for individual patients with knowledge of detailed dimensions of the surgical valve and radiographic and echocardiographic measurements of the patient's anatomy. Understanding the complexities of the ViV procedure can lead surgeons to make choices during the original surgical valve implantation that can make a future ViV operation more technically feasible years before it is required. PMID:29743998

  3. Early Outcomes for Valve-in-valve Transcatheter Aortic Valve Replacement in Degenerative Freestyle Bioprostheses.

    PubMed

    Sang, Stephane Leung Wai; Beute, Tyler; Heiser, John; Berkompas, Duane; Fanning, Justin; Merhi, William

    2017-11-20

    Transcatheter aortic valve replacement (TAVR) is used increasingly to treat bioprosthetic valve failure. A paucity of data exists regarding valve-in-valve (ViV) TAVR in degenerated Freestyle stentless bioprostheses (FSBs). This study sought to evaluate the feasibility and short-term outcomes of ViV TAVR in previously placed FSB. From October 2014 to September 2016, 22 patients at a single institution underwent ViV TAVR with a self-expanding transcatheter valve for a failing FSB. Patient baseline characteristics and clinical outcomes data were collected retrospectively and entered into a dedicated database. The mean patient age was 74 ± 9years, and the mean Society of Thoracic Surgeons' Risk score was 9.0 ± 7.4%. Ten patients presented with acute heart failure requiring urgent intervention. The most common mode of failure of the FSB was regurgitation caused by a flail or malcoapting leaflet. Seventeen (77%) patients had a modified subcoronary implantation, 3 (14%) had a full root replacement, and 2 (9%) had a root inclusion. Device success using a self-expanding transcatheter valve was 95%, all via transfemoral approach. The mean implant depth was 7 ± 3 mm. Thirty-day survival was 100%. No patient had more than mild paravalvular regurgitation at 30days, and the permanent pacemaker rate was 9%. The mean hospital stay after intervention was 5 ± 2days. ViV TAVR using a self-expanding transcatheter valve is safe, feasible, and can be used successfully to treat a failed FSB. Procedural challenges suggest referral to valve centers of excellence. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Determination of 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine with mass selective detection.

    PubMed

    Hughes, D L; Ritter, D J; Wilson, R D

    2001-11-01

    Method development and validation studies have been completed on an assay that will allow the determination of 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine. The accurate determination of 2,4-D in urine is an important factor in monitoring worker and population exposure. These studies successfully validated a method for the detection of 2,4-D in urine at a limit of quantitation (LOQ) of 5.00 ppb (parts per billion) using gas chromatography with mass selective detection (GC/MSD). The first study involved the determination of 2,4-D in control human urine and urine samples fortified with 2,4-D. Due to chromatographic interference, a second study was conducted using 14C-2,4-D to verify the recoverability of 2,4-D from human urine at low levels using the GC/MSD method. The second study supports the results of the original data. The 2,4-D was extracted from human urine using a procedure involving hydrolysis using potassium hydroxide, followed by a liquid-liquid extraction into methylene chloride. The extracted samples were derivatized with diazomethane. The methylated fraction was analyzed by GC/MSD. Quantitation was made by comparison to methylated reference standards of 2,4-D. Aliquots fortified at 5-, 50-, and 500-ppb levels were analyzed. The overall mean recovery for all fortified samples was 90.3% with a relative standard deviation of 14.31%.

  5. Transcatheter treatment of severe tricuspid regurgitation with the MitraClip system.

    PubMed

    Hammerstingl, Christoph; Schueler, Robert; Malasa, Margarita; Werner, Nikos; Nickenig, Georg

    2016-03-07

    The aim of this study was to show technical principles and feasibility of transcatheter tricuspid valve repair by use of the MitraClip system. Three consecutive patients were treated successfully for severe symptomatic Tricuspid regurgitation. Three-dimensional transoesophageal echocardiography confirmed reduction of measured effective regurgitant orifice in all patients [effective regurgitant orifice area-baseline/post-procedure (cm(2)): 0.7/0.3; 1.5/0.8; 0.4/0.1], which was accompanied by an increase in left ventricular stroke volumes [baseline/post-procedure (mL): 42.8/45.4; 38/45; 35.2/45], decrease of measured levels of N terminal pro brain natriuretic peptide (pg/mL: baseline/post-procedure: 548/440; 2526/1702; 1754/623), and significant relief of clinical symptoms for chronic right heart failure in all patients. Transcatheter tricuspid valve repair by use of interventional edge-to-edge repair with the MitraClip system was feasible, and safe in three consecutive patients. Reduction of tricuspid insufficiency associates with relief of clinical symptoms for right heart failure. This strategy seems a promising treatment option for patients at prohibitive surgical risk. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  6. Patient-specific simulation of guidewire deformation during transcatheter aortic valve implantation.

    PubMed

    Vy, Phuoc; Auffret, Vincent; Castro, Miguel; Badel, Pierre; Rochette, Michel; Haigron, Pascal; Avril, Stéphane

    2018-06-01

    Transcatheter aortic valve implantation is a recent mini-invasive procedure to implant an aortic valve prosthesis. Prosthesis positioning in transcatheter aortic valve implantation appears as an important aspect for the success of the intervention. Accordingly, we developed a patient-specific finite element framework to predict the insertion of the stiff guidewire, used to position the aortic valve. We simulated the guidewire insertion for 2 patients based on their pre-operative CT scans. The model was designed to primarily predict the position and the angle of the guidewires in the aortic valve, and the results were successfully compared with intraoperative images. The present paper describes extensively the numerical model, which was solved by using the ANSYS software with an implicit resolution scheme, as well as the stabilization techniques which were used to overcome numerical instabilities. We performed sensitivity analysis on the properties of the guidewire (curvature angle, curvature radius, and stiffness) and the conditions of insertion (insertion force and orientation). We also explored the influence of the model parameters. The accuracy of the model was quantitatively evaluated as the distance and the angle difference between the simulated guidewires and the intraoperative ones. A good agreement was obtained between the model predictions and intraoperative views available for 2 patient cases. In conclusion, we showed that the shape of the guidewire in the aortic valve was mainly determined by the geometry of the patient's aorta and by the conditions of insertion (insertion force and orientation). Copyright © 2018 John Wiley & Sons, Ltd.

  7. Transcatheter renal denervation for the treatment of resistant arterial hypertension: the Swiss expert consensus.

    PubMed

    Wuerzner, Gregoire; Muller, Olivier; Erne, Paul; Cook, Stéphane; Sudano, Isabella; Lüscher, Thomas F; Noll, Georg; Kaufmann, Urs; Rickli, Hans; Waeber, Bernard; Kaiser, Christophe; Sticherling, Christian; Pechère-Bertschi, Antoinette; Baumgartner, Iris; Jacob, Augustinus L; Burnier, Michel; Qanadli, Salah D

    2014-03-20

    Transcatheter (or percutaneous) renal denervation is a novel technique developed for the treatment of resistant hypertension. So far, only one randomised controlled trial has been published, which has shown a reduction of office blood pressure. The Swiss Society of Hypertension, the Swiss Society of Cardiology, The Swiss Society of Angiology and the Swiss Society of Interventional Radiology decided to establish recommendations to practicing physicians and specialists for good clinical practice. The eligibility of patients for transcatheter renal denervation needs (1.) confirmation of truly resistant hypertension, (2.) exclusion of secondary forms of hypertension, (3.) a multidisciplinary decision confirming the eligibility, (4.) facilities that guarantee procedural safety and (5.) a long-term follow-up of the patients, if possible in cooperation with a hypertension specialist. These steps are essential until long-term data on safety and efficacy are available.

  8. The Fluid Mechanics of Transcatheter Heart Valve Leaflet Thrombosis in the Neosinus.

    PubMed

    Midha, Prem A; Raghav, Vrishank; Sharma, Rahul; Condado, Jose F; Okafor, Ikechukwu U; Rami, Tanya; Kumar, Gautam; Thourani, Vinod H; Jilaihawi, Hasan; Babaliaros, Vasilis; Makkar, Raj R; Yoganathan, Ajit P

    2017-10-24

    Transcatheter heart valve (THV) thrombosis has been increasingly reported. In these studies, thrombus quantification has been based on a 2-dimensional assessment of a 3-dimensional phenomenon. Postprocedural, 4-dimensional, volume-rendered CT data of patients with CoreValve, Evolut R, and SAPIEN 3 transcatheter aortic valve replacement enrolled in the RESOLVE study (Assessment of Transcatheter and Surgical Aortic Bioprosthetic Valve Dysfunction With Multimodality Imaging and Its Treatment with Anticoagulation) were included in this analysis. Patients on anticoagulation were excluded. SAPIEN 3 and CoreValve/Evolut R patients with and without hypoattenuated leaflet thickening were included to study differences between groups. Patients were classified as having THV thrombosis if there was any evidence of hypoattenuated leaflet thickening. Anatomic and THV deployment geometries were analyzed, and thrombus volumes were computed through manual 3-dimensional reconstruction. We aimed to identify and evaluate risk factors that contribute to THV thrombosis through the combination of retrospective clinical data analysis and in vitro imaging in the space between the native and THV leaflets (neosinus). SAPIEN 3 valves with leaflet thrombosis were on average 10% further expanded (by diameter) than those without (95.5±5.2% versus 85.4±3.9%; P <0.001). However, this relationship was not evident with the CoreValve/Evolut R. In CoreValve/Evolut Rs with thrombosis, the thrombus volume increased linearly with implant depth ( R 2 =0.7, P <0.001). This finding was not seen in the SAPIEN 3. The in vitro analysis showed that a supraannular THV deployment resulted in a nearly 7-fold decrease in stagnation zone size (velocities <0.1 m/s) when compared with an intraannular deployment. In addition, the in vitro model indicated that the size of the stagnation zone increased as cardiac output decreased. Although transcatheter aortic valve replacement thrombosis is a multifactorial process

  9. Transcatheter Therapies for Treating Tricuspid Regurgitation.

    PubMed

    Rodés-Cabau, Josep; Hahn, Rebecca T; Latib, Azeem; Laule, Michael; Lauten, Alexander; Maisano, Francesco; Schofer, Joachim; Campelo-Parada, Francisco; Puri, Rishi; Vahanian, Alec

    2016-04-19

    Tricuspid valve (TV) disease has been relatively neglected, despite the known association between severe tricuspid regurgitation (TR) and mortality. Few patients undergo isolated tricuspid surgery, which remains associated with high in-hospital mortality rates, particularly in patients with prior left-sided valve surgery. Patients with severe TR are often managed medically for years before TV repair or replacement. Current guidelines recommend TV repair in the presence of a dilated tricuspid annulus at the time of a left-sided valve surgical intervention, even if regurgitation is mild. This proposed algorithm aims to prevent the inevitable progression to severe TR and the need for a second surgical intervention. Recently, novel transcatheter treatment options were developed for treating patients with severe TR and right heart failure with prohibitive surgical risk. Here we describe currently available transcatheter treatment options for severe TR implanted at different levels: the junction between vena cavae and right atrium; the tricuspid annulus; or between TV leaflets, improving coaptation. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  10. A cost-utility analysis of transcatheter versus surgical aortic valve replacement for the treatment of aortic stenosis in the population with intermediate surgical risk.

    PubMed

    Tam, Derrick Y; Hughes, Avery; Fremes, Stephen E; Youn, Saerom; Hancock-Howard, Rebecca L; Coyte, Peter C; Wijeysundera, Harindra C

    2018-05-01

    Although transcatheter aortic valve implantation has been shown to be noninferior to surgical aortic valve replacement in patients with severe aortic stenosis at intermediate surgical risk, the cost-effectiveness of this strategy in this population is unknown. Our objective was to conduct a cost-utility analysis comparing transcatheter aortic valve implantation with surgical aortic valve replacement in the population with intermediate risk severe aortic stenosis. A fully probabilistic Markov model with 30-day cycles was constructed from the Canadian third-party payer's perspective to estimate the difference in cost and effectiveness (measured as quality-adjusted life years) of transcatheter aortic valve implantation versus surgical aortic valve replacement for intermediate-risk patients over a lifetime time horizon, discounted at 1.5% per annum. Clinical trial data from The Placement of Aortic Transcatheter Valve 2 informed the efficacy inputs. Costs (adjusted to 2016 Canadian dollars) were obtained from the Canadian Institute of Health Information and the Ontario Schedule of Benefits. Incremental cost-effectiveness ratios were calculated. In the base-case analysis, total lifetime costs for transcatheter aortic valve implantation were $10,548 higher than surgical aortic valve replacement but added 0.23 quality-adjusted life years, for an incremental cost-effectiveness ratio of $46,083/quality-adjusted life-years gained. Deterministic 1-way analyses showed that the incremental cost-effectiveness ratio was sensitive to rates of complications and cost of the transcatheter aortic valve implantation prosthesis. There was moderate-to-high parameter uncertainty; transcatheter aortic valve implantation was the preferred option in only 52.7% and 55.4% of the simulations at a $50,000 and $100,000 per quality-adjusted life years willingness-to-pay thresholds, respectively. On the basis of current evidence, transcatheter aortic valve implantation may be cost-effective for the

  11. Comparison of medium-term results of transcatheter correction versus surgical treatment for secundum type atrial septal defect combined with pulmonary valve stenosis.

    PubMed

    Xu, Xu-Dong; Liu, Su-Xuan; Zhao, Xian-Xian; Qin, Yong-Wen

    2014-01-01

    This study was undertaken to compare the clinical results of traditional surgery and a percutaneous procedure for secundum type atrial septal defect (ASD) combined with pulmonary valve stenosis (PS). A total of 78 consecutive patients were identified between March 2004 and July 2012 in our institution. Thirty-five patients (44.9%) underwent percutaneous correction and the remaining 43 patients (55.1%) were treated surgically. All patients had simultaneous complete correction in both groups and no serious complications occurred. The surgical group was significantly younger (13.9 ± 13.0 versus 31.0 ± 17.5 years, P < 0.001) and had a longer mean hospital stay (12.6 ± 4.7 versus 5.3 ± 1.5 days, P < 0.001). There were no significant differences in defect size (18.0 ± 7.9 versus 16.9 ± 8.4 mm, P = 0.553) and transvalvular gradient detected by transthoracic echocardiography (TTE) (74.7 ± 28.3 versus 87.6 ± 37.8 mmHg, P = 0.089) between the two groups. Significant tricuspid regurgitation (TR) decreased from 66% to 14% in the transcatheter group and from 40% to 9% in the surgical group. Mild pulmonary regurgitation was detected in 8 patients in the transcatheter cohort and in 6 patients in the surgical cohort after the procedure. At last follow-up, 83% and 93% of the patients in the transcatheter and surgical groups, respectively, were free of any symptoms, and a significant improvement from preprocedure was observed in the transcatheter group but not in the surgical group (P = 0.005 and P = 0.062). In conclusion, transcatheter correction is a valuable alternative to surgery and allows more patients to be effectively treated in China.

  12. Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation.

    PubMed

    Allen, Keith B; Chhatriwalla, Adnan K; Cohen, David J; Saxon, John T; Aggarwal, Sanjeev; Hart, Anthony; Baron, Suzanne; Davis, J Russell; Pak, Alex F; Dvir, Danny; Borkon, A Michael

    2017-11-01

    Valve-in-valve transcatheter aortic valve replacement is less effective in small surgical bioprostheses. We evaluated the feasibility of bioprosthetic valve fracture with a high-pressure balloon to facilitate valve-in-valve transcatheter aortic valve replacement. In vitro bench testing on aortic tissue valves was performed on 19-mm and 21-mm Mitroflow (Sorin, Milan, Italy), Magna and Magna Ease (Edwards Lifesciences, Irvine, CA), Trifecta and Biocor Epic (St. Jude Medical, Minneapolis, MN), and Hancock II and Mosaic (Medtronic, Minneapolis, MN). High-pressure balloons Tru Dilation, Atlas Gold, and Dorado (C.R. Bard, Murray Hill, NJ) were used to determine which valves could be fractured and at what pressure fracture occurred. Mitroflow, Magna, Magna Ease, Mosaic, and Biocor Epic surgical valves were successfully fractured using high-pressures balloon 1 mm larger than the labeled valve size whereas Trifecta and Hancock II surgical valves could not be fractured. Only the internal valve frame was fractured, and the sewing cuff was never disrupted. Manufacturer's rated burst pressures for balloons were exceeded, with fracture pressures ranging from 8 to 24 atmospheres depending on the surgical valve. Testing further demonstrated that fracture facilitated the expansion of previously constrained, underexpanded transcatheter valves (both balloon and self-expanding) to the manufacturer's recommended size. Bench testing demonstrates that the frame of most, but not all, bioprosthetic surgical aortic valves can be fractured using high-pressure balloons. The safety of bioprosthetic valve fracture to optimize valve-in-valve transcatheter aortic valve replacement in small surgical valves requires further clinical investigation. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement.

    PubMed

    Chhatriwalla, Adnan K; Allen, Keith B; Saxon, John T; Cohen, David J; Aggarwal, Sanjeev; Hart, Anthony J; Baron, Suzanne J; Dvir, Danny; Borkon, A Michael

    2017-07-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) using a high-pressure balloon can be performed to facilitate VIV TAVR. We report data from 20 consecutive clinical cases in which BVF was successfully performed before or after VIV TAVR by inflation of a high-pressure balloon positioned across the valve ring during rapid ventricular pacing. Hemodynamic measurements and calculation of the valve effective orifice area were performed at baseline, immediately after VIV TAVR, and after BVF. BVF was successfully performed in 20 patients undergoing VIV TAVR with balloon-expandable (n=8) or self-expanding (n=12) transcatheter valves in Mitroflow, Carpentier-Edwards Perimount, Magna and Magna Ease, Biocor Epic and Biocor Epic Supra, and Mosaic surgical valves. Successful fracture was noted fluoroscopically when the waist of the balloon released and by a sudden drop in inflation pressure, often accompanied by an audible snap. BVF resulted in a reduction in the mean transvalvular gradient (from 20.5±7.4 to 6.7±3.7 mm Hg, P <0.001) and an increase in valve effective orifice area (from 1.0±0.4 to 1.8±0.6 cm 2 , P <0.001). No procedural complications were reported. BVF can be performed safely in small surgical valves to facilitate VIV TAVR with either balloon-expandable or self-expanding transcatheter valves and results in reduced residual transvalvular gradients and increased valve effective orifice area. © 2017 American Heart Association, Inc.

  14. Transcatheter vessel occlusion: angiographic results versus clinical success

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feldman, L.; Greenfield, A.J.; Waltman, A.C.

    1983-04-01

    A review was made of 219 transcatheter vessel occlusion procedures performed over a ten-year period for control of hemorrhage, tumor palliation, or blood supply redistribution prior to intra-arterial chemotherapy. Complete angiographic success was obtained in 85% of the procedures, with partial success in 8%; complete clinical success was achieved in 53% of patients, with partial success in 23%. the most satisfactory clinical results were obtained with hemorrhagic gastritis and pelvic trauma. Embolizations for duodenal ulcer hemorrhage and transhepatic variceal occlusion were the least clinically successful, although isobutyl-cyanoacrylate appeared to be a significant improvement in angiographic therapy for duodenal ulcer. Themore » overall complication rate was 13%, with one third of the complications clinically silent. These results indicate that transcatheter vessel occlusion is a relatively safe and effective method for control of hemorrhage or tumor infarction.« less

  15. Concomitant transcatheter aortic valve and left ventricular assist device implantation.

    PubMed

    Baum, Christina; Seiffert, Moritz; Treede, Hendrik; Reichenspurner, Hermann; Deuse, Tobias

    2013-01-01

    Relevant aortic regurgitation (AR) requires surgical repair at the time of left ventricular assist device (LVAD) implantation to reduce recirculation and ensure adequate forward flow. We report here on a patient with moderate AR in a noncalcified aortic valve and extensive calcification of the ascending aorta. The latter precluded aortic-crossclamping and, thus, surgical intervention on the aortic valve. Although there were no valvular or annular calcifications, a JenaValve transcatheter heart valve was successfully placed transapically with subsequent LVAD implantation in one operation. We believe concomitant transcatheter aortic valve implantation (TAVI) and LVAD implantation is a promising hybrid procedure, even in patients with pure AR.

  16. [Early complications following transcatheter occlusion of perimembranous ventricular septal defects in children].

    PubMed

    Li, Jun-jie; Zhang, Zhi-wei; Qian, Ming-yang; Wang, Hui-shen; Li, Yu-fen

    2006-11-01

    To evaluate the early complications during and after transcatheter closure of perimembranous ventricular septal defects (PMVSDs) in children. A total of 223 patients received transcatheter closure of PMVSDs from March 2002 to December 2005 in our hospital were included in this retrospective study. The overall complications rate was 26.9% (60/223). Major complications occurred in 9 patients (4.0%) including III degrees atrioventricular block (AVB) in 2 (0.9%), hemolysis in 3 (1.3%) and surgical interventions in 4 patients (1.8%) because of device malposition (1), mild aortic regurgitation (2) and device embolization (1) and all 4 patients recovered without further complications. The 2 patients with III degrees AVB were completely recovered to normal sinus rhythm after 7 days treatment with temporary pacemaker and corticosteroid. Hemolysis in 3 patients disappeared after corticosteroid treatment. Minor complications occurred in 51 patients (22.8%) including bundle branch block (BBB) in 37 (16.6%), first-degree AVB in 2 (0.9%), second-degree AVB in 1 (0.4%), new-onset mild aortic regurgitation in 5 (2.2%) and new-onset mild to moderate tricuspid regurgitation in 6 patients (2.6%). Except for right bundle branch blocks, other BBBs were treated with albumin and corticosteroid and completely recovered. No treatment was applied for new-onset valve regurgitations. There was no death in all 223 patients. Early complications post PMVSDs in children are mostly minor with good prognosis and the prognosis for major complications post PMVSDs is good after proper treatment.

  17. Meta-analysis of transcatheter closure versus medical therapy for patent foramen ovale in prevention of recurrent neurological events after presumed paradoxical embolism.

    PubMed

    Agarwal, Shikhar; Bajaj, Navkaranbir Singh; Kumbhani, Dharam J; Tuzcu, E Murat; Kapadia, Samir R

    2012-07-01

    In this study, a meta-analysis of observational studies was performed to compare the rate of recurrent neurological events (RNE) between transcatheter closure and medical management of patients with cryptogenic stroke/transient ischemic attack (TIA) and concomitant patent foramen ovale (PFO). A significant controversy surrounds the optimal strategy for treatment of cryptogenic stroke/TIA and coexistent PFO. We conducted a MEDLINE search with standard search terms to determine eligible studies. Adjusted incidence rates of RNE were 0.8 (95% confidence interval [CI]: 0.5 to 1.1) events and 5.0 (95% CI: 3.6 to 6.9) events/100 person-years (PY) in the transcatheter closure and medical management arms, respectively. Meta-analysis of the limited number of comparative studies and meta-regression analysis suggested that the transcatheter closure might be superior to the medical therapy in prevention of RNE after cryptogenic stroke. Comparison of the anticoagulation and antiplatelet therapy subgroups of the medical arm yielded a significantly lower risk of RNE within patients treated with anticoagulants. Device-related complications were encountered at the rate of 4.1 (95% CI: 3.2 to 5.0) events/100 PY, with atrial arrhythmias being the most frequent complication. After transcatheter closure, RNE did not seem to be related to the pre-treatment shunt size or the presence of residual shunting in the follow-up period. Significant benefit of transcatheter PFO closure was apparent in elderly patients, patients with concomitant atrial septal aneurysm, and patients with thrombophilia. Rates of RNE with transcatheter closure and medical therapy in patients presenting with cryptogenic stroke or TIA were estimated at 0.8 and 5.0 events/100 PY. Further randomized controlled trials are needed to conclusively compare these 2 management strategies. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  18. Transcatheter therapy for hepatic malignancy: standardization of terminology and reporting criteria.

    PubMed

    Brown, Daniel B; Gould, Jennifer E; Gervais, Debra A; Goldberg, S Nahum; Murthy, Ravi; Millward, Steven F; Rilling, William S; Geschwind, Jean-Francois S; Salem, Riad; Vedantham, Suresh; Cardella, John F; Soulen, Michael C

    2009-07-01

    The field of interventional oncology includes tumor ablation as well as the use of transcatheter therapies such as embolization, chemoembolization, and radioembolization. Terminology and reporting standards for tumor ablation have been developed. The development of standardization of terminology and reporting criteria for transcatheter therapies should provide a similar framework to facilitate the clearest communication among investigators and provide the greatest flexibility in comparing established and emerging technologies. An appropriate vehicle for reporting the various aspects of catheter directed therapy is outlined, including classification of therapies and procedure terms, appropriate descriptors of imaging guidance, and terminology to define imaging and pathologic findings. Methods for standardizing the reporting of outcomes toxicities, complications, and other important aspects that require attention when reporting clinical results are addressed. It is the intention of the group that adherence to the recommendations will facilitate achievement of the group's main objective: improved precision and communication for reporting the various aspects of transcatheter management of hepatic malignancy that will translate to more accurate comparison of technologies and results and, ultimately, to improved patient outcomes.

  19. Transcatheter Mitral Valve Replacement for Native and Failed Bioprosthetic Mitral Valves

    PubMed Central

    Sarkar, Kunal; Reardon, Michael J.; Little, Stephen H.; Barker, Colin M.; Kleiman, Neal S.

    2017-01-01

    Transcatheter mitral valve replacement (TMVR) is a novel approach for treatment of severe mitral regurgitation. A number of TMVR devices are currently undergoing feasibility trials using both transseptal and transapical routes for device delivery. Overall experience worldwide is limited to fewer than 200 cases. At present, the 30-day mortality exceeds 30% and is attributable to both patient- and device-related factors. TMVR has been successfully used to treat patients with degenerative mitral stenosis (DMS) as well as failed mitral bioprosthesis and mitral repair using transcatheter mitral valve-in-valve (TMViV)/valve-in-ring (ViR) repair. These patients are currently treated with devices designed for transcatheter aortic valve replacement. Multicenter registries have been initiated to collect outcomes data on patients currently undergoing TMViV/ViR and TMVR for DMS and have confirmed the feasibility of TMVR in these patients. However, the high periprocedural and 30-day event rates underscore the need for further improvements in device design and multicenter randomized studies to delineate the role of these technologies in patients with mitral valve disease. PMID:29743999

  20. Clinical efficiency and safety analysis of transcatheter closure of multiple atrial septal defects in adults.

    PubMed

    Song, Zhi-Yuan; He, Guo-Xiang; Shu, Mao-Qin; Hu, Hou-Yuan; Tong, Shi-Fei; Ran, Bo-Li; Liu, Jian-Ping; Li, Yong-Hua; Jing, Tao

    2009-03-01

    Transcatheter closure of atrial septal defects (ASDs) is currently a reliable alternative to surgery, even though challenging in patients with multiple ASDs. The aim of this study was to evaluate the clinical efficiency and safety of transcatheter closure in multiple ASDs. Multiple ASDs were diagnosed by transthoracic echocardiography (TTE) or transesophageal echocardiography (TEE). The occlusive condition and distance between 2 adjacent ASDs were measured by TTE examination. Then, the number and size of the occluder(s) was determined. TTE examinations were performed after transcatheter closure as follow-up. The transcatheter procedure was successful in 15 patients with multiple ASDs, using a single occluder in 9 patients and 2 occluders in the remaining 6 patients. Overall, 21 ASD occluders were implanted. During a follow-up period of 6 mo to 5 y, a slight residual shunt was found in 1 patient without any symptoms; a moderate residual shunt was identified at the inferior vena cava and the occluder was removed by surgery 1 mo after procedure. Other complications, including endocarditis, arrhythmia, thromboembolism, and atrioventricular valve damage were not recorded in any of the 15 patients during the follow-up period. Transcatheter closure of multiple ASDs is safe and efficient. Two occluders are necessary for the distance of 2 ASDs more than 7 mm, and a single occluder is sufficient for those 7 mm or less. Copyright (c) 2009 Wiley Periodicals, Inc.

  1. Self-expanding platinum-coated nitinol devices for transcatheter closure of atrial septal defect: prevention of nickel release.

    PubMed

    Lertsapcharoen, Pornthep; Khongphatthanayothin, Apichai; Srimahachota, Suphot; Leelanukrom, Ruenreong

    2008-06-01

    A variety of nitinol-containing devices for transcatheter closure of atrial septal defects (ASD) has been widely used. However, there is concern about the release of nickel after nitinol device implantation. In this study, a platinum-coated nitinol device was braided from nanoplatinum-coated nitinol wires in order to prevent nickel release. The serum nickel levels before and after device implantation and the 1-year results were evaluated. Thirty-one patients, aged 4-59 years, and weighing 13.7-90.0 kg, underwent transcatheter closure. Blood samples for serum nickel levels were taken before, 1 day, 1 week, 1 month and 3 months after implantation. Twenty-nine (93.6%) patients had a successful implantation. The mean ASD diameter was 19.7 +/- 4.8 mm (range 10-30 mm). Procedure-related complications included transient brachial plexus injury in 1 patient and transient dysrhythmia in 4 patients. All 29 patients had complete closure within 1 month after implantation. The mean serum nickel levels at baseline and at 1 day, 1 week, 1 month and 3 months after implantation were 0.65 +/- 0.28, 0.63 +/- 0.18, 0.67 +/- 0.34, 0.55 +/- 0.16, 0.52 +/- 0.14 ng/ml, respectively. There was no significant difference in serum nickel levels before and after implantation. There were no device-related complications at 1-year follow up. Transcatheter ASD closure using a platinum-coated nitinol device can be performed safely and successfully with good outcomes. Nano-coating of platinum on nitinol wires can prevent nickel release following device implantation.

  2. Quantitative IR microscopy and spectromics open the way to 3D digital pathology.

    PubMed

    Bobroff, Vladimir; Chen, Hsiang-Hsin; Delugin, Maylis; Javerzat, Sophie; Petibois, Cyril

    2017-04-01

    Currently, only mass-spectrometry (MS) microscopy brings a quantitative analysis of chemical contents of tissue samples in 3D. Here, the reconstruction of a 3D quantitative chemical images of a biological tissue by FTIR spectro-microscopy is reported. An automated curve-fitting method is developed to extract all intense absorption bands constituting IR spectra. This innovation benefits from three critical features: (1) the correction of raw IR spectra to make them quantitatively comparable; (2) the automated and iterative data treatment allowing to transfer the IR-absorption spectrum into a IR-band spectrum; (3) the reconstruction of an 3D IR-band matrix (x, y, z for voxel position and a 4 th dimension with all IR-band parameters). Spectromics, which is a new method for exploiting spectral data for tissue metadata reconstruction, is proposed to further translate the related chemical information in 3D, as biochemical and anatomical tissue parameters. An example is given with oxidative stress distribution and the reconstruction of blood vessels in tissues. The requirements of IR microscopy instrumentation to propose 3D digital histology as a clinical routine technology is briefly discussed. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Safety and Efficacy of Transcatheter Closure of Patent Ductus Arteriosus With Severe Mitral Regurgitation in Adults.

    PubMed

    Wang, Zhongkai; Chen, Tao; Chen, Liang; Qin, Yongwen; Zhao, Xianxian

    2016-01-01

    Transcatheter closure is the usual treatment for patent ductus arteriosus (PDA), but its safety and efficacy have not been reported in adult PDA patients with severe mitral regurgitation. A retrospective study on 27 consecutive patients diagnosed with PDA and severe mitral regurgitation and treated using transcatheter closure between September 2010 and September 2012 at the Department of Cardiology of Changhai Hospital in Changhai, China. Left ventricular (LV) diastolic volume and function, pulmonary artery pressure, and instantaneous reverse-flow volume were examined by echocardiography before PDA closure, immediately after closure, and 1 year after closure. After the procedure, the LV diastolic volume (P<.05) and instantaneous reverse-flow volume (P<.001) were significantly decreased. There was no effect on the ejection fraction (P>.05). Pulmonary arterial systolic pressure was unchanged 1 year after closure (from 46.41 ± 19.92 mm Hg to 45.43 ± 13.64 mm Hg; P=.58). All procedures were uneventful and only mild complications occurred (hemolysis in 2 cases, subcutaneous hematoma in 4 cases, and fever in 2 cases). Transcatheter closure can decrease the LV volume and instantaneous reverse-flow volume in adult PDA patients with severe mitral regurgitation. This procedure is effective and has a good safety profile.

  4. Percutaneous Direct Needle Puncture and Transcatheter N-butyl Cyanoacrylate Injection Techniques for the Embolization of Pseudoaneurysms and Aneurysms of Arteries Supplying the Hepato-pancreato-biliary System and Gastrointestinal Tract

    PubMed Central

    Yadav, Rajanikant R; Boruah, Deb K; Bhattacharyya, Vishwaroop; Prasad, Raghunandan; Kumar, Sheo; Saraswat, V A; Kapoor, V K; Saxena, Rajan

    2016-01-01

    Aims: The aim of this study was to evaluate the safety and clinical efficacy of percutaneous direct needle puncture and transcatheter N-butyl cyanoacrylate (NBCA) injection techniques for the embolization of pseudoaneurysms and aneurysms of arteries supplying the hepato-pancreato-biliary (HPB) system and gastrointestinal (GI) tract. Subjects and Methods: A hospital-based cross-sectional retrospective study was conducted, where the study group comprised 11 patients with pseudoaneurysms/aneurysms of arteries supplying the HPB system and GI tract presenting to a tertiary care center from January 2015 to June 2016. Four patients (36.4%) underwent percutaneous direct needle puncture of pseudoaneurysms with NBCA injection, 3 patients (27.3%) underwent transcatheter embolization with NBCA as sole embolic agent, and in 4 patients (36.4%), transcatheter NBCA injection was done along with coil embolization. Results: This retrospective study comprised 11 patients (8 males and 3 females) with mean age of 35.8 years ± 1.6 (standard deviation [SD]). The mean volume of NBCA: ethiodized oil (lipiodol) mixture injected by percutaneous direct needle puncture was 0.62 ml ± 0.25 (SD) (range = 0.5–1 ml), and by transcatheter injection, it was 0.62 ml ± 0.37 (SD) (range = 0.3–1.4 ml). Embolization with NBCA was technically and clinically successful in all patients (100%). No recurrence of bleeding or recurrence of pseudoaneurysm/aneurysm was noted in our study. Conclusions: Percutaneous direct needle puncture of visceral artery pseudoaneurysms and NBCA glue injection and transcatheter NBCA injection for embolization of visceral artery pseudoaneurysms and aneurysms are cost-effective techniques that can be used when coil embolization is not feasible or has failed. PMID:28123838

  5. Middle-term results of trans-catheter creation of atrial communication in patients receiving mechanical circulatory support.

    PubMed

    O'Byrne, Michael L; Glatz, Andrew C; Rossano, Joseph W; Schiavo, Kellie L; Dori, Yoav; Rome, Jonathan J; Gillespie, Matthew J

    2015-06-01

    To describe our center's middle-term outcomes following trans-catheter creation of atrial communication (ASD) in patients on mechanical circulatory support. Trans-catheter creation of an ASD in patients on mechanical circulatory support is an adjuvant therapy to reduce left atrial pressure and associated morbidity. Data on middle term outcomes following this procedure, specifically in regards to the fate of the ASD, are limited. Retrospective observational study of consecutive children and adults undergoing trans-catheter creation of an atrial septal communication between 1/1/2006 and 5/1/2014, reviewing their baseline characteristics, procedural details, and data from follow-up. Over the study period, 37/227 (16%) subjects undergoing veno-arterial extra-corporeal membrane oxygenation (VA-ECMO) underwent trans-catheter creation of an atrial communication. Mortality on VA-ECMO support in this subgroup was 19%, with an additional 24% transitioning to ventricular assist device. Of the 57% who survived to separation from VA-ECMO, 16/21 (76%) had residual atrial communications. 56% of these underwent closure procedures. Following trans-catheter creation of ASD, a residual ASD is present in the majority of assessable survivors and represents a potential volume overload and/or right to left shunt that may need to be addressed. © 2015 Wiley Periodicals, Inc.

  6. Transcatheter closure of moderate-to-large patent ductus arteriosus in infants using Amplatzer duct occluder.

    PubMed

    Wang, Jou-Kou; Wu, Mei-Hwan; Lin, Ming-Tai; Chiu, Shuenn-Nan; Chen, Chun-An; Chiu, Hsin-Hui

    2010-02-01

    There are difficulties in transcatheter closure of patent ductus arteriosus (PDA) in infants. The 46 infants (mean age 6.2+/-2.7 months; mean body weight 6.3+/-1.6 kg) who underwent PDA closure using the Amplatzer duct occluder (ADO). The indication for using an ADO was a ductus diameter > or =2.5 or 3 mm. Device diameter selected was 1-3 mm larger than ductal diameter. The mean systolic pulmonary artery pressure was 40.9+/-18.2 mmHg. The mean Qp/Qs ratio was 3.1+/-1.2. The mean ductus diameter was 3.3+/-0.8 mm. ADO was successfully deployed in 45 patients. Failure occurred in 1 case. The mean diameter of device used was 5.4+/-1.1 mm. No severe complications occurred. At the 1-month echocardiographic follow-up, a small residual shunt was present in 4 of 45 patients and had disappeared in all 4 patients at the 3-month follow-up. One patient developed a moderate degree of left ventricular outflow tract obstruction 2.3 years after the procedure. Transcatheter closure of PDA in infants using the ADO is a safe and effective method.

  7. Stent and leaflet stresses in a 26-mm first-generation balloon-expandable transcatheter aortic valve.

    PubMed

    Xuan, Yue; Krishnan, Kapil; Ye, Jian; Dvir, Danny; Guccione, Julius M; Ge, Liang; Tseng, Elaine E

    2017-05-01

    Transcatheter aortic valve replacement is established therapy for high-risk and inoperable patients with severe aortic stenosis, but questions remain regarding long-term durability. Valve design influences durability. Increased leaflet stresses in surgical bioprostheses have been correlated with degeneration; however, transcatheter valve leaflet stresses are unknown. From 2007 to 2014, a majority of US patients received first-generation balloon-expandable transcatheter valves. Our goal was to determine stent and leaflet stresses in this valve design using finite element analyses. A 26-mm Sapien Transcatheter Heart Valve (Edwards Lifesciences, Inc, Irvine, Calif) underwent high-resolution microcomputed tomography scanning to develop precise 3-dimensional geometry of the leaflets, the stent, and the polyethylene terephthalate elements. The stent was modeled using 3-dimensional elements and the leaflets were modeled using shell elements. Stent material properties were based on stainless steel, whereas those for leaflets were obtained from surgical bioprostheses. Noncylindrical Sapien valve geometry was also simulated. Pressure loading to 80 mm Hg and 120 mm Hg was performed using ABAQUS finite element software (Dassault Systèmes, Waltham, Mass). At 80 mm Hg, maximum principal stresses on Sapien leaflets were 1.31 megaspascals (MPa). Peak leaflet stress was observed at commissural tips where leaflets connected to the stent. Maximum principal stresses for the stent were 188.91 MPa and located at stent tips where leaflet commissures were attached. Noncylindrical geometry increased peak principal leaflet stresses by 16%. Using exact geometry from high-resolution scans, the 26-mm Sapien Transcatheter Heart Valve showed that peak stresses for both stent and leaflets were present at commissural tips where leaflets were attached. These regions would be prone to leaflet degeneration. Understanding stresses in first-generation transcatheter valves allows comparison to

  8. Surgery Versus Transcatheter Interventions for Significant Paravalvular Prosthetic Leaks.

    PubMed

    Millán, Xavier; Bouhout, Ismail; Nozza, Anna; Samman, Karla; Stevens, Louis-Mathieu; Lamarche, Yoan; Serra, Antonio; Asgar, Anita W; El-Hamamsy, Ismail; Cartier, Raymond; Pellerin, Michel; Noble, Stephane; Demers, Phillipe; Ibrahim, Reda; Jolicœur, E Marc; Bouchard, Denis

    2017-10-09

    This study sought to assess the relative merit of surgical correction (SC) versus transcatheter reduction on long-term outcomes in patients with significant paravalvular leak (PVL) refractory to medical therapy. PVL is the most frequent dysfunction following prosthetic valve replacement. Although repeat surgery is the gold standard, transcatheter reduction (TR) of PVL has been associated with reduced mortality. From 1994 to 2014, 231 patients underwent SC (n = 151) or TR (n = 80) PVL correction. Propensity matching and Cox proportional hazards regression models were used to assess the effect of either intervention on long-term rates of all-cause death or hospitalization for heart failure. Survival after TR and SC were further compared with the survival in a matched general population and to matched patients undergoing their first surgical valve replacement. Over a median follow-up of 3.5 years, SC was associated with an important reduction in all-cause death or hospitalization for heart failure compared with TR (hazard ratio: 0.28; 95% confidence interval: 0.18 to 0.44; p < 0.001). There was a trend towards reduced all-cause death following SC versus TR (hazard ratio: 0.61; 95% confidence interval: 0.37 to 1.02; p = 0.06). Neither intervention normalized survival when compared with a general population or patients undergoing their first surgical valve replacement. In patients with significant prosthetic PVL, surgery is associated with better long-term outcomes compared with transcatheter intervention, but results in important perioperative mortality and morbidity. Future studies are needed in the face of increasing implementation of transcatheter PVL interventions across the world. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  9. Design of 3-D adipospheres for quantitative metabolic study

    PubMed Central

    Akama, Takeshi; Leung, Brendan M.; Labuz, Joseph M.; Takayama, Shuichi; Chun, Tae-Hwa

    2017-01-01

    Quantitative assessment of adipose mitochondrial activity is critical for better understanding of adipose tissue function in obesity and diabetes. While the two-dimensional (2-D) tissue culture method has been sufficient to discover key molecules that regulate adipocyte differentiation and function, the method is insufficient to determine the role of extracellular matrix (ECM) molecules and their modifiers, such as matrix metalloproteinases (MMPs), in regulating adipocyte function in three-dimensional (3-D) in vivo-like microenvironments. By using a 3-D hanging drop tissue culture system, we are able to produce scalable 3-D adipospheres that are suitable for quantitative mitochondrial study in 3-D microenvironment. PMID:28244051

  10. Transcatheter closure of a large patent ductus arteriosus using jugular access in an infant.

    PubMed

    Fernandes, Precylia; Assaidi, Anass; Baruteau, Alban-Elouen; Fraisse, Alain

    2018-03-01

    Trans-catheter device closure of patent ductus arteriosus (PDA) via femoral route is the commonly used, safe and effective procedure. Trans-jugular approach has been successfully used in older children with interrupted inferior vena cava. We report a case of successful occlusion of PDA using Amplatzer duct occluder (ADO) via trans-jugular approach following difficulties encountered in gaining femoral venous access. A 6-month-old male infant, weighing 8 kg was admitted for percutaneous catheter closure of PDA. Echocardiogram showed a 4.5 mm duct and left heart dilatation. Femoral venous access was not possible; therefore, we decided to use a trans-jugular approach. The duct was occluded using 8/6 mm ADO. Successful closure of the duct was confirmed with an aortogram. Post procedure echocardiogram showed no residual shunt across the duct. We highlight that trans-catheter closure of PDA using jugular venous access is safe and effective even in infants.

  11. Percutaneous closure of acute aorto-right ventricular fistula following transcatheter bicuspid aortic valve replacement.

    PubMed

    Nakamura, Kenta; Passeri, Jonathan J; Inglessis-Azuaje, Ignacio

    2017-07-01

    We report a case of acute aorto-right ventricular fistula following transcatheter bicuspid aortic valve replacement and subsequent percutaneous closure. The diagnosis and treatment of this rare complication is illustrated through multi-modality imaging. We hypothesize that the patient's heavily calcified bicuspid aortic valve anatomy led to asymmetric deployment of the transcatheter aortic valve replacement (TAVR) prosthesis, traumatizing the right sinus of Valsalva at the distal edge of the TAVR stent and ultimately fistulized to the right ventricle. The patient acutely decompensated with heart failure five days after TAVR and underwent emergent intervention. The aorto-right ventricular fistula was closed using an 18-mm septal occluder device with marked clinical recovery. Transcatheter closure is a viable treatment option for acute aorto-right ventricular fistula. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  12. Percutaneous Transcatheter Mitral Valve Replacement: Patient-specific Three-dimensional Computer-based Heart Model and Prototyping.

    PubMed

    Vaquerizo, Beatriz; Theriault-Lauzier, Pascal; Piazza, Nicolo

    2015-12-01

    Mitral regurgitation is the most prevalent valvular heart disease worldwide. Despite the widespread availability of curative surgical intervention, a considerable proportion of patients with severe mitral regurgitation are not referred for treatment, largely due to the presence of left ventricular dysfunction, advanced age, and comorbid illnesses. Transcatheter mitral valve replacement is a promising therapeutic alternative to traditional surgical valve replacement. The complex anatomical and pathophysiological nature of the mitral valvular complex, however, presents significant challenges to the successful design and implementation of novel transcatheter mitral replacement devices. Patient-specific 3-dimensional computer-based models enable accurate assessment of the mitral valve anatomy and preprocedural simulations for transcatheter therapies. Such information may help refine the design features of novel transcatheter mitral devices and enhance procedural planning. Herein, we describe a novel medical image-based processing tool that facilitates accurate, noninvasive assessment of the mitral valvular complex, by creating precise three-dimensional heart models. The 3-dimensional computer reconstructions are then converted to a physical model using 3-dimensional printing technology, thereby enabling patient-specific assessment of the interaction between device and patient. It may provide new opportunities for a better understanding of the mitral anatomy-pathophysiology-device interaction, which is of critical importance for the advancement of transcatheter mitral valve replacement. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  13. K-t GRAPPA-accelerated 4D flow MRI of liver hemodynamics: influence of different acceleration factors on qualitative and quantitative assessment of blood flow.

    PubMed

    Stankovic, Zoran; Fink, Jury; Collins, Jeremy D; Semaan, Edouard; Russe, Maximilian F; Carr, James C; Markl, Michael; Langer, Mathias; Jung, Bernd

    2015-04-01

    We sought to evaluate the feasibility of k-t parallel imaging for accelerated 4D flow MRI in the hepatic vascular system by investigating the impact of different acceleration factors. k-t GRAPPA accelerated 4D flow MRI of the liver vasculature was evaluated in 16 healthy volunteers at 3T with acceleration factors R = 3, R = 5, and R = 8 (2.0 × 2.5 × 2.4 mm(3), TR = 82 ms), and R = 5 (TR = 41 ms); GRAPPA R = 2 was used as the reference standard. Qualitative flow analysis included grading of 3D streamlines and time-resolved particle traces. Quantitative evaluation assessed velocities, net flow, and wall shear stress (WSS). Significant scan time savings were realized for all acceleration factors compared to standard GRAPPA R = 2 (21-71 %) (p < 0.001). Quantification of velocities and net flow offered similar results between k-t GRAPPA R = 3 and R = 5 compared to standard GRAPPA R = 2. Significantly increased leakage artifacts and noise were seen between standard GRAPPA R = 2 and k-t GRAPPA R = 8 (p < 0.001) with significant underestimation of peak velocities and WSS of up to 31 % in the hepatic arterial system (p <0.05). WSS was significantly underestimated up to 13 % in all vessels of the portal venous system for k-t GRAPPA R = 5, while significantly higher values were observed for the same acceleration with higher temporal resolution in two veins (p < 0.05). k-t acceleration of 4D flow MRI is feasible for liver hemodynamic assessment with acceleration factors R = 3 and R = 5 resulting in a scan time reduction of at least 40 % with similar quantitation of liver hemodynamics compared with GRAPPA R = 2.

  14. Transcatheter aortic valve implantation in patients with bicuspid aortic valve stenosis.

    PubMed

    Wijesinghe, Namal; Ye, Jian; Rodés-Cabau, Josep; Cheung, Anson; Velianou, James L; Natarajan, Madhu K; Dumont, Eric; Nietlispach, Fabian; Gurvitch, Ronen; Wood, David A; Tay, Edgar; Webb, John G

    2010-11-01

    We evaluated transcatheter aortic valve implantation (TAVI) in high-risk patients with bicuspid aortic valve (BAV) stenosis. TAVI shows promise in the treatment of severe stenosis of triscupid aortic valves, especially in high-risk patients. However, BAV stenosis has been considered a contraindication to TAVI. Eleven patients (age 52 to 90 years) with symptomatic severe BAV stenosis underwent TAVI at 3 Canadian tertiary hospitals between May 2006 and April 2010. All patients were considered high risk for surgical aortic valve replacement. Edwards-SAPIEN transcatheter heart valves (Edwards Lifesciences, Inc., Irvine, California) were used. Transfemoral or transapical access was selected, depending on the adequacy of femoral access. Access was transfemoral in 7 patients and transapical in 4 patients. There were no intraprocedural complications. Significant symptomatic and hemodynamic improvement was observed in 10 of 11 patients. Baseline aortic valve area of 0.65 ± 0.17 cm(2) and mean transaortic pressure gradient of 41 ± 22.4 mm Hg were improved to 1.45 ± 0.3 cm(2) and 13.4 ± 5.7 mm Hg, respectively. Two patients had moderate perivalvular leaks. At the 30-day follow-up there were 2 deaths due to multisystem failure in 2 transapical patients. In 1 patient an undersized, suboptimally positioned, unstable valve required late conversion to open surgery. TAVI in selected high-risk patients with severe BAV stenosis can be successfully performed with acceptable clinical outcomes but will require further evaluation. Copyright © 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  15. 4D Sommerfeld quantization of the complex extended charge

    NASA Astrophysics Data System (ADS)

    Bulyzhenkov, Igor E.

    2017-12-01

    Gravitational fields and accelerations cannot change quantized magnetic flux in closed line contours due to flat 3D section of curved 4D space-time-matter. The relativistic Bohr-Sommerfeld quantization of the imaginary charge reveals an electric analog of the Compton length, which can introduce quantitatively the fine structure constant and the Plank length.

  16. A novel technique for transcatheter patent ductus arteriosus closure in extremely preterm infants using commercially available technology.

    PubMed

    Zahn, Evan M; Nevin, Phillip; Simmons, Charles; Garg, Ruchira

    2015-02-01

    To describe a new technique for transcatheter patent ductus arteriosus (PDA) closure in extremely preterm infants using commercially available technology. PDA in premature neonates continues to be a significant clinical problem contributing importantly to both morbidity and mortality. Surgical ligation and medical therapy both have their drawbacks. Hospital records and catheterization reports of all premature neonates (< 32 weeks gestation) who underwent transcatheter PDA closure between March 2013 and February 2014 were reviewed. Particular attention was paid to procedural details, complications, and short and mid-term outcomes. Six premature infants born at gestational ages ranging between 26 and 31 weeks (median, 26 weeks) underwent attempted transcatheter PDA closure using the Amplatzer Vascular Plug II (AVP II). Median age and weight was 21.5 days (16-80 days) and 1,180 g (870-2,240 g), respectively. Fluoroscopy and echocardiography were used to guide device. Contrast angiography was not used in any patient. Complete closure was achieved in all patients with no major procedural complications. Median fluoroscopy and procedural times were 9.4 (0-19.5) and 51.5 (33-87) min, respectively. All patients were alive at the time of this report. There were no instances of device migration, left pulmonary artery (LPA), or aortic coarctation. This preliminary study demonstrates that transcatheter PDA closure can be successfully performed in extremely preterm neonates using currently available technology with a high success rate and a low incidence of complications. This report also describes a novel transvenous approach using a combination of echocardiography and judicious use of fluoroscopy to avoid arterial access in this fragile patient population. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.

  17. Sizing of patent ductus arteriosus in adults for transcatheter closure using the balloon pull-through technique.

    PubMed

    Shafi, Nabil A; Singh, Gagan D; Smith, Thomas W; Rogers, Jason H

    2018-05-01

    To describe a novel balloon sizing technique used during adult transcatheter patent ductus arteriosus (PDA) closure. In addition, to determine the clinical and procedural outcomes in six patients who underwent PDA balloon sizing with subsequent deployment of a PDA occluder device. Transcatheter PDA closure in adults has excellent safety and procedural outcomes. However, PDA sizing in adults can be challenging due to variable defect size, high flow state, or anatomical complexity. We describe a series of six cases where the balloon- pull through technique was successfully performed for PDA sizing prior to transcatheter closure. Consecutive adult patients undergoing adult PDA closure at our institution were studied retrospectively. A partially inflated sizing balloon was pulled through the defect from the aorta into the pulmonary artery and the balloon waist diameter was measured. Procedural success and clinical outcomes were obtained. Six adult patients underwent successful balloon pull-through technique for PDA sizing during transcatheter PDA closure, since conventional angiography often gave suboptimal opacification of the defect. All PDAs were treated with closure devices based on balloon PDA sizing with complete closure and no complications. In three patients that underwent preprocedure computed tomography, the balloon size matched the CT derived measurements. The balloon pull-through technique for PDA sizing is a safe and accurate sizing modality in adults undergoing transcatheter PDA closure. © 2017 Wiley Periodicals, Inc.

  18. Denoising and 4D visualization of OCT images

    PubMed Central

    Gargesha, Madhusudhana; Jenkins, Michael W.; Rollins, Andrew M.; Wilson, David L.

    2009-01-01

    We are using Optical Coherence Tomography (OCT) to image structure and function of the developing embryonic heart in avian models. Fast OCT imaging produces very large 3D (2D + time) and 4D (3D volumes + time) data sets, which greatly challenge ones ability to visualize results. Noise in OCT images poses additional challenges. We created an algorithm with a quick, data set specific optimization for reduction of both shot and speckle noise and applied it to 3D visualization and image segmentation in OCT. When compared to baseline algorithms (median, Wiener, orthogonal wavelet, basic non-orthogonal wavelet), a panel of experts judged the new algorithm to give much improved volume renderings concerning both noise and 3D visualization. Specifically, the algorithm provided a better visualization of the myocardial and endocardial surfaces, and the interaction of the embryonic heart tube with surrounding tissue. Quantitative evaluation using an image quality figure of merit also indicated superiority of the new algorithm. Noise reduction aided semi-automatic 2D image segmentation, as quantitatively evaluated using a contour distance measure with respect to an expert segmented contour. In conclusion, the noise reduction algorithm should be quite useful for visualization and quantitative measurements (e.g., heart volume, stroke volume, contraction velocity, etc.) in OCT embryo images. With its semi-automatic, data set specific optimization, we believe that the algorithm can be applied to OCT images from other applications. PMID:18679509

  19. Regional Systems of Care to Optimize Outcomes in Patients Undergoing Transcatheter Aortic Valve Replacement.

    PubMed

    Stub, Dion; Lauck, Sandra; Lee, May; Gao, Min; Humphries, Karin; Chan, Albert; Cheung, Anson; Cook, Richard; Della Siega, Anthony; Leipsic, Jonathon; Charania, Jay; Dvir, Danny; Latham, Tim; Polderman, Jopie; Robinson, Simon; Wong, Daniel; Thompson, Christopher R; Wood, David; Ye, Jian; Webb, John

    2015-12-28

    This study sought to describe the development of a multicenter, transcatheter aortic valve replacement program and regional systems of care intended to optimize coordinated, efficient, and appropriate delivery of this new therapy. Transcatheter aortic valve replacement (TAVR) has become an accepted treatment option for patients with severe aortic stenosis who are at high surgical risk. Regional systems of care have led to improvements in outcomes for patients undergoing intervention for myocardial infarction, cardiac arrest, and stroke. We implemented a regional system of care for patients undergoing TAVR in British Columbia, Canada. We describe a prospective observational cohort of 583 patients who underwent TAVR in British Columbia between 2012 and 2014. Regionalization of TAVR care in British Columbia refers to a centrally coordinated, funded, and evaluated program led by a medical director and a multidisciplinary advisory group that oversees planning, access to care, and quality of outcomes at the 4 provincial sites. Risk-stratified case selection for transfemoral TAVR is performed by heart teams at each site on the basis of consensus provincial indications. Referrals for lower volume and more complicated TAVR, including nontransfemoral access and valve-in-valve procedures, are concentrated at a single site. In-hospital and 30-day outcomes are reported. The median age was 83 years (interquartile range [IQR]: 78 to 87 years) and median STS score was 6% (IQR: 4% to 8%). Transfemoral access was performed in 499 (85.6%) cases and nontransfemoral in 84 (14.4%). Transcatheter valve-in-valve procedures in for failed bioprosthetic valves were performed in 43 patients (7.4%). A balloon-expandable valve was inserted in 386 (66.2%) and a self-expanding valve in 189 (32.4%). All-cause 30-day mortality was 3.5%. All-cause in-hospital mortality and disabling stroke occurred in 3.1% and 1.9%, respectively. Median length of stay was 3 days (IQR: 3 to 6 days), with 92.8% of

  20. Comparison of outcomes of patients with left ventricular ejection fractions ≤30% versus ≥30% having transcatheter aortic valve implantation (from the German Transcatheter Aortic Valve Interventions Registry).

    PubMed

    Schaefer, Ulrich; Zahn, Ralf; Abdel-Wahab, Mohamed; Gerckens, Ulrich; Linke, Axel; Schneider, Steffen; Eggebrecht, Holger; Sievert, Horst; Figulla, Hans Reiner; Senges, Jochen; Kuck, Karl Heinz

    2015-03-01

    Transcatheter aortic valve implantation (TAVI) is rapidly evolving in Germany. Especially severe reduced left ventricular ejection fraction (LVEF) is known as a prominent risk factor for adverse outcome in open heart surgery. Thus, the data of the prospective multicenter German Transcatheter Aortic Valve Interventions Registry were analyzed for outcomes in patients with severe depressed LVEF. Data of 1,432 patients were consecutively collected after transcatheter aortic valve implantation. Patients were divided into 2 groups (A: LVEF ≤30%, n = 169, age 79.9 ± 6.7 years, logES 34.2 ± 17.8%; B: LVEF >30%, n = 1,263, age 82.0 ± 6.1 years, logES 18.9 ± 12.0%), and procedural success rates, New York Heart Association classification, and quality of life were compared at 30 days and 1 year, respectively. Technical success was achieved in 95.9% (A) and 97.6% (B). Survival and the New York Heart Association classification at 30 days demonstrated an excellent outcome in both groups. There was a significant improvement according to the self-assessment in health condition (0 to 100 scale) with a much larger gain in group A (28 vs 19 patients, p <0.0001). Nevertheless, low cardiac output syndrome (12.3% vs 5.9%, p <0.01) and resuscitation (10.4% vs 5.6%, p <0.05) were more frequently seen in group A, contributing to a higher mortality at 30 days (14.3% vs 7.2%) and 1 year (33.7% vs 18.1%, p <0.001). In conclusion, this real-world registry demonstrated a comparably high success rate for patients with severe reduced LVEF and an early improvement in functional status as demonstrated by substantial benefit, despite a doubled postprocedural mortality. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Latest-Generation Transcatheter Aortic Valve Replacement Devices and Procedures.

    PubMed

    Chamandi, Chekrallah; Puri, Rishi; Rodriguez-Gabella, Tania; Rodés-Cabau, Josep

    2017-09-01

    Transcatheter aortic valve replacement (TAVR) is a well-established treatment for patients with severe symptomatic aortic stenosis who are at high or prohibitive surgical risk. More recently, TAVR has emerged as a valid alternative to surgical aortic valve replacement for treating intermediate-risk patients, and several studies are currently evaluating the role of TAVR in low-risk patients. Transcatheter heart valve (THV) technologies have evolved considerably over time, and important iterations have been implemented in many of the latest-generation devices to (1) reduce the size and improve delivery system properties; (2) improve valve deployment, repositioning, and retrievability; and (3) reduce paravalvular leaks. This article reviews the main characteristics of, and clinical results associated with, the newer-generation THVs while providing an overview of novel TAVR indications. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  2. Quantitative 3D electromagnetic field determination of 1D nanostructures from single projection

    DOE PAGES

    Phatak, C.; Knoop, L. de; Houdellier, F.; ...

    2016-05-01

    One-dimensional (1D) nanostructures have been regarded as the most promising building blocks for nanoelectronics and nanocomposite material systems as well as for alternative energy applications. Although they result in confinement of a material, their properties and interactions with other nanostructures are still very much three-dimensional (3D) in nature. In this work, we present a novel method for quantitative determination of the 3D electromagnetic fields in and around 1D nanostructures using a single electron wave phase image, thereby eliminating the cumbersome acquisition of tomographic data. Using symmetry arguments, we have reconstructed the 3D magnetic field of a nickel nanowire as wellmore » as the 3D electric field around a carbon nanotube field emitter, from one single projection. The accuracy of quantitative values determined here is shown to be a better fit to the physics at play than the value obtained by conventional analysis. Moreover the 3D reconstructions can then directly be visualized and used in the design of functional 3D architectures built using 1D nanostructures.« less

  3. Quantitative 3D electromagnetic field determination of 1D nanostructures from single projection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phatak, C.; Knoop, L. de; Houdellier, F.

    One-dimensional (1D) nanostructures have been regarded as the most promising building blocks for nanoelectronics and nanocomposite material systems as well as for alternative energy applications. Although they result in confinement of a material, their properties and interactions with other nanostructures are still very much three-dimensional (3D) in nature. In this work, we present a novel method for quantitative determination of the 3D electromagnetic fields in and around 1D nanostructures using a single electron wave phase image, thereby eliminating the cumbersome acquisition of tomographic data. Using symmetry arguments, we have reconstructed the 3D magnetic field of a nickel nanowire as wellmore » as the 3D electric field around a carbon nanotube field emitter, from one single projection. The accuracy of quantitative values determined here is shown to be a better fit to the physics at play than the value obtained by conventional analysis. Moreover the 3D reconstructions can then directly be visualized and used in the design of functional 3D architectures built using 1D nanostructures.« less

  4. Mitral Transcatheter Technologies

    PubMed Central

    Maisano, Francesco; Buzzatti, Nicola; Taramasso, Maurizio; Alfieri, Ottavio

    2013-01-01

    Mitral valve regurgitation (MR) is often diagnosed in patients with heart failure and is associated with worsening of symptoms and reduced survival. While surgery remains the gold standard treatment in low-risk patients with degenerative MR, in high-risk patients and in those with functional MR, transcatheter procedures are emerging as an alternative therapeutic option. MitraClip® is the device with which the largest clinical experience has been gained to date, as it offers sustained clinical benefit in selected patients. Further to MitraClip implantation, several additional approaches are developing, to better match with the extreme variability of mitral valve disease. Not only repair is evolving, initial steps towards percutaneous mitral valve implantation have already been undertaken, and initial clinical experience has just started. PMID:23908865

  5. Evaluation of COPD's diaphragm motion extracted from 4D-MRI

    NASA Astrophysics Data System (ADS)

    Swastika, Windra; Masuda, Yoshitada; Kawata, Naoko; Matsumoto, Koji; Suzuki, Toshio; Iesato, Ken; Tada, Yuji; Sugiura, Toshihiko; Tanabe, Nobuhiro; Tatsumi, Koichiro; Ohnishi, Takashi; Haneishi, Hideaki

    2015-03-01

    We have developed a method called intersection profile method to construct a 4D-MRI (3D+time) from time-series of 2D-MRI. The basic idea is to find the best matching of the intersection profile from the time series of 2D-MRI in sagittal plane (navigator slice) and time series of 2D-MRI in coronal plane (data slice). In this study, we use 4D-MRI to semiautomatically extract the right diaphragm motion of 16 subjects (8 healthy subjects and 8 COPD patients). The diaphragm motion is then evaluated quantitatively by calculating the displacement of each subjects and normalized it. We also generate phase-length map to view and locate paradoxical motion of the COPD patients. The quantitative results of the normalized displacement shows that COPD patients tend to have smaller displacement compared to healthy subjects. The average normalized displacement of total 8 COPD patients is 9.4mm and the average of normalized displacement of 8 healthy volunteers is 15.3mm. The generated phase-length maps show that not all of the COPD patients have paradoxical motion, however if it has paradoxical motion, the phase-length map is able to locate where does it occur.

  6. Treatment of type I endoleaks using transcatheter embolization with onyx.

    PubMed

    Eberhardt, Karla Maria; Sadeghi-Azandaryani, Mojtaba; Worlicek, Stefanie; Koeppel, Thomas; Reiser, Maximilian F; Treitl, Marcus

    2014-02-01

    To report a single-center experience with transcatheter embolization of type I endoleaks using the liquid embolic agent Onyx, an ethylene vinyl alcohol copolymer. Eight patients (4 men; mean age 74.8 years, range 63-86) with 10 type I endoleaks (6 abdominal and 4 thoracic) diagnosed 2 days to 9 years after endovascular repair were treated with Onyx embolization because cuff extension was precluded by an insufficient landing zone in 6 cases and an unsuitable aortic diameter in 2. Endoleaks were accessed with a 4-F diagnostic catheter and a coaxially introduced dimethylsulfoxide-compatible microcatheter. Onyx-34 was predominantly applied due to its high viscosity; patent side branches were coil embolized prior to Onyx delivery in 3 cases. Technical success of the procedure was achieved in all cases. The mean volume of Onyx used for abdominal endoleaks was 11.8 mL (range 3.0-25.5) and 19.4 mL (range 4.5-31.5) for thoracic endoleaks. The average duration of the procedure was 76.7 minutes (range 34.5-110.6), and the average radiation dose area product was 18.8 cGy*cm (2) (range 10.6-55.8). Reperfusion of the endoleak was detected in one case 2 days after the procedure. A second case showed an occluded endoleak but a small trace of contrast between the aortic wall and the stent-graft. Non-target embolization was not found in any case. Mean follow-up was 13.2 months (range 8-24). The mean reduction in diameters for thoracic aneurysms after 6 and 12 months was 0.4 and 0.9 cm, respectively, and 0.6 and 1.2 cm, respectively, for abdominal aneurysms. Transcatheter embolization of type I endoleaks using Onyx is a simple, safe, and sustainable treatment option with a high primary success rate for cases in which stent-graft extension is not possible. The benefit of additional coil embolization remains uncertain.

  7. Transcatheter umbrella closure of valvular and paravalvular leaks.

    PubMed

    Hourihan, M; Perry, S B; Mandell, V S; Keane, J F; Rome, J J; Bittl, J A; Lock, J E

    1992-11-15

    Our aim was to adapt the technique of transcatheter umbrella closure of intracardiac defects for closure of valvular and paravalvular defects. The double-umbrella device developed by Rashkind and Cuaso has been safely and effectively delivered across a host of intracardiac defects, but transcatheter closure of valvular and paravalvular leaks has not been reported. Between February 1987 and September 1990, eight patients who were believed to be poor operative candidates were taken to the catheterization laboratory for transcatheter double-umbrella closure of a valvular or a paravalvular leak. Four patients had a paravalvular leak around a prosthetic aortic valve. The other four patients had a valvular leak: one patient with a regurgitant native aortic valve after a Stansel procedure and three patients with a regurgitant porcine valve in a left ventricular apex to descending aorta conduit. Placement of a double-umbrella device was attempted in seven of the eight patients and was successful in all seven. Device placement was not attempted in one patient because of the crescentic shape of his defect. Two patients required two devices for each closure; the other five required only one device each. Angiography, performed on six patients after device closure, demonstrated that three patients had a completely occluded defect, two had trivial residual flow and one patient had mild residual flow through the device. All significant complications occurred in one patient who had hemolysis and oliguria that resolved when the initial umbrella was replaced by a larger device. In addition, two devices migrated to the patient's pulmonary arteries but were retrieved in the catheterization laboratory without difficulty. No other early or late complications occurred in 21 to 50 months of follow-up. Of the four patients with a paravalvular leak, the one who did not receive a device died at operation, one patient died at operation for an associated defect (in the operating room the

  8. Infective endocarditis following transcatheter edge-to-edge mitral valve repair: A systematic review.

    PubMed

    Asmarats, Lluis; Rodriguez-Gabella, Tania; Chamandi, Chekrallah; Bernier, Mathieu; Beaudoin, Jonathan; O'Connor, Kim; Dumont, Eric; Dagenais, François; Paradis, Jean-Michel; Rodés-Cabau, Josep

    2018-05-10

    To assess the clinical characteristics, management, and outcomes of patients diagnosed with infective endocarditis (IE) after edge-to-edge mitral valve repair with the MitraClip device. Transcatheter edge-to-edge mitral valve repair has emerged as an alternative to surgery in high-risk patients. However, few data exist on IE following transcatheter mitral procedures. Four electronic databases (PubMed, Google Scholar, Embase, and Cochrane Library) were searched for original published studies on IE after edge-to-edge transcatheter mitral valve repair from 2003 to 2017. A total of 10 publications describing 12 patients with definitive IE (median age 76 years, 55% men) were found. The mean logistic EuroSCORE/EuroSCORE II were 41% and 45%, respectively. The IE episode occurred early (within 12 months post-procedure) in nine patients (75%; within the first month in five patients). Staphylococcus aureus was the most frequent (60%) causal microorganism, and severe mitral regurgitation was present in all cases but one. Surgical mitral valve replacement (SMVR) was performed in most (67%) patients, and the mortality associated with the IE episode was high (42%). IE following transcatheter edge-to-edge mitral valve repair is a rare but life-threatening complication, usually necessitating SMVR despite the high-risk profile of the patients. These results highlight the importance of adequate preventive measures and a prompt diagnosis and treatment of this serious complication. © 2018 Wiley Periodicals, Inc.

  9. Transcatheter device closure of pseudoaneurysms of the left ventricular wall: An emerging therapeutic option.

    PubMed

    Madan, Tarun; Juneja, Manish; Raval, Abhishek; Thakkar, Bhavesh

    2016-02-01

    Left ventricular pseudoaneurysm is a rare but serious complication of acute myocardial infarction and cardiac surgery. While surgical intervention is the conventional therapeutic option, transcatheter closure can be considered in selected patients with suitable morphology of the pseudoaneurysm. We report a case of successful transcatheter closure of a left ventricular pseudoaneurysm orifice and isolation of the sac using an Amplatzer septal occluder. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  10. Comparison of transcatheter laser and direct-current shock ablation of endocardium near tricuspid anulus

    NASA Astrophysics Data System (ADS)

    Zhang, Yu-Zhen; Wang, Shi-Wen; Li, Junheng

    1993-03-01

    Forty to eighty percent of the patients with accessory pathways (APs) manifest themselves by tachyarrhythmias. Many of these patients needed either life-long medical therapy or surgery. In order to avoid the discomfort and expenses in surgical procedures, closed chest percutaneous catheter ablation of APs became a potentially desirable therapeutic approach. Many investigations indicated that ablation of right APs by transcatheter direct current (dc) shock could cause life-threatening arrhythmias, right coronary arterical (RCA) spasm, etc. With the development of transcatheter laser technique, it has been used in drug-incurable arrhythmias. The results show that laser ablation is much safer than surgery and electric shock therapy. The purpose of this study is to explore the effectiveness, advantages, and complications with transcatheter Nd:YAG laser and dc shock in the ablation of right atrioventricular accessory pathways in the atrium near the tricuspid annulus (TA) in 20 dogs.

  11. Transcatheter aortic valve implantation: durability of clinical and hemodynamic outcomes beyond 3 years in a large patient cohort.

    PubMed

    Gurvitch, R; Wood, D A; Tay, E L; Leipsic, J; Ye, J; Lichtenstein, S V; Thompson, C R; Carere, R G; Wijesinghe, N; Nietlispach, F; Boone, R H; Lauck, S; Cheung, A; Webb, J G

    2010-09-28

    Although short- and medium-term outcomes after transcatheter aortic valve implantation are encouraging, long-term data on valve function and clinical outcomes are limited. Consecutive high-risk patients who had been declined as surgical candidates because of comorbidities but who underwent successful transcatheter aortic valve implantation with a balloon-expandable valve between January 2005 and December 2006 and survived past 30 days were assessed. Clinical, echocardiographic, and computed tomographic follow-up examinations were performed. Seventy patients who underwent successful procedures and survived longer than 30 days were evaluated at a minimum follow-up of 3 years. At a median follow-up of 3.7 years (interquartile range 3.4 to 4.3 years), survival was 57%. Survival at 1, 2, and 3 years was 81%, 74%, and 61%, respectively. Freedom from reoperation was 98.5% (1 patient with endocarditis). During this early procedural experience, 11 patients died within 30 days, and 8 procedures were unsuccessful. When these patients were included, overall survival was 51%. Transaortic pressure gradients increased from 10.0 mm Hg (interquartile range 8.0 to 12.0 mm Hg) immediately after the procedure to 12.1 mm Hg (interquartile range 8.6 to 16.0 mm Hg) after 3 years (P=0.03). Bioprosthetic valve area decreased from a mean of 1.7±0.4 cm(2) after the procedure to 1.4±0.3 cm(2) after 3 years (P<0.01). Aortic incompetence after implantation was trivial or mild in 84% of cases and remained unchanged or improved over time. There were no cases of structural valvular deterioration, stent fracture, deformation, or valve migration. Transcatheter aortic valve implantation demonstrates good medium- to long-term durability and preserved hemodynamic function, with no evidence of structural failure. The procedure appears to offer an adequate and lasting resolution of aortic stenosis in selected patients.

  12. Quality and Safety in Health Care, Part XXIX: The Transcatheter Valve Therapy Registry.

    PubMed

    Harolds, Jay A

    2017-11-01

    The American College of Cardiology, the Society of Thoracic Surgeons, and other organizations cooperated to form the Transcatheter Valve Therapy Registry. This registry studies information on the outcome of valve therapy device placement with a transcatheter approach. The companies that manufacture these devices can use the registry to meet the post-product sale surveillance requirements of the US Food and Drug Administration. There will also be linkage to the registry information from the Society of Thoracic Surgeons Adult Cardiac Surgery Database, which has information on open cardiac valve surgery.

  13. GATA4-mediated cardiac hypertrophy induced by D-myo-inositol 1,4,5-tris-phosphate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu Zhiming; Zhu Shanjun; Liu Daoyan

    2005-12-16

    We evaluated the effects of D-myo-inositol 1,4,5-tris-phosphate on cardiac hypertrophy. D-myo-inositol 1,4,5-tris-phosphate augmented cardiac hypertrophy as evidenced by its effects on DNA synthesis, protein synthesis, and expression of immediate-early genes c-myc and c-fos, {beta}-myosin heavy chain, and {alpha}-actin. The administration of D-myo-inositol 1,4,5-tris-phosphate increased the expression of nuclear factor of activated T-cells and cardiac-restricted zinc finger transcription factor (GATA4). Real-time quantitative RT-PCR showed that D-myo-inositol 1,4,5-tris-phosphate-induced GATA4 mRNA was significantly enhanced even in the presence of the calcineurin inhibitor, cyclosporine A. The effect of D-myo-inositol 1,4,5-tris-phosphate was blocked after inhibition of inositol-trisphosphate receptors but not after inhibition of c-Raf/mitogen-activated proteinmore » kinase kinase (MEK)/mitogen-activated protein kinase (ERK) or p38 mitogen-activated protein kinase pathways. The study shows that D-myo-inositol 1,4,5-tris-phosphate-induced cardiac hypertrophy is mediated by GATA4 but independent from the calcineurin pathway.« less

  14. Transcatheter Pulmonary Valve Replacement by Hybrid Approach Using a Novel Polymeric Prosthetic Heart Valve: Proof of Concept in Sheep

    PubMed Central

    Xu, Tong-yi; Zhang, Zhi-gang; Li, Xin; Han, Lin; Xu, Zhi-yun

    2014-01-01

    Background Since 2000, transcatheter pulmonary valve replacement has steadily advanced. However, the available prosthetic valves are restricted to bioprosthesis which have defects like poor durability. Polymeric heart valve is thought as a promising alternative to bioprosthesis. In this study, we introduced a novel polymeric transcatheter pulmonary valve and evaluated its feasibility and safety in sheep by a hybrid approach. Methods We designed a novel polymeric trileaflet transcatheter pulmonary valve with a balloon-expandable stent, and the valve leaflets were made of 0.1-mm expanded polytetrafluoroethylene (ePTFE) coated with phosphorylcholine. We chose glutaraldehyde-treated bovine pericardium valves as control. Pulmonary valve stents were implanted in situ by a hybrid transapical approach in 10 healthy sheep (8 for polymeric valve and 2 for bovine pericardium valve), weighing an average of 22.5±2.0 kg. Angiography and cardiac catheter examination were performed after implantation to assess immediate valvular functionality. After 4-week follow-up, angiography, echocardiography, computed tomography, and cardiac catheter examination were used to assess early valvular function. One randomly selected sheep with polymeric valve was euthanized and the explanted valved stent was analyzed macroscopically and microscopically. Findings Implantation was successful in 9 sheep. Angiography at implantation showed all 9 prosthetic valves demonstrated orthotopic position and normal functionality. All 9 sheep survived at 4-week follow-up. Four-week follow-up revealed no evidence of valve stent dislocation or deformation and normal valvular and cardiac functionality. The cardiac catheter examination showed the peak-peak transvalvular pressure gradient of the polymeric valves was 11.9±5.0 mmHg, while that of two bovine pericardium valves were 11 and 17 mmHg. Gross morphology demonstrated good opening and closure characteristics. No thrombus or calcification was seen

  15. Dual or Single Antiplatelet Therapy After Transcatheter Aortic Valve Implantation? A Systematic Review and Meta-Analysis.

    PubMed

    Vavuranakis, Manolis; Siasos, Gerasimos; Zografos, Theodoros; Oikonomou, Evangelos; Vrachatis, Dimitris; Kalogeras, Konstantinos; Papaioannou, Theodoros; Kolokathis, Michail-Aggelos; Moldovan, Carmen; Tousoulis, Dimitrios

    2016-01-01

    Transcatheter aortic valve implantation (TAVI) has undeniably earned a prestigious post in the quiver of interventional cardiologists against symptomatic severe aortic stenosis. Cerebrovascular events are listed within the most frequent complications. We performed a systematic search of EMBASE, MEDLINE, and the Cochrane library from inception to March 2016 for the following search terms (transcatheter AND antiplatelet) OR (transcatheter AND antithrombotic) to retrieve studies of dual antiplatelet treatment (DAPT) and single antiplatelet treatment (SAPT) in patients after TAVI to study thrombotic, hemorrhagic and cardiovascular events at 30 days post procedure. From a total of 208 records 4 studies met inclusion criteria. In the included studies, 286 patients were enrolled in the DAPT group and 354 patients in the SAPT group. There was no difference in all-cause mortality, cardiovascular mortality, stroke, and myocardial infraction 30 days post TAVI between DAPT and SAPT. However, patients in the DAPT group had a significantly increased incidence of lethal and major bleeding at 30 days of follow-up and the incidence of the combined end-point of stroke, spontaneous MI, all-cause mortality and major bleeding was significantly higher in the DAPT group in comparison to the SAPT group. DAPT compared to SAPT in patients after TAVI increases incidence of hemorrhagic events with no benefits in terms of thrombotic events and cardiovascular mortality. However, these data must be interpreted cautiously and the choice of DAPT over SAPT must be based on an individual patient characteristic according to medical practice criteria.

  16. Costs of periprocedural complications in patients treated with transcatheter aortic valve replacement: results from the Placement of Aortic Transcatheter Valve trial.

    PubMed

    Arnold, Suzanne V; Lei, Yang; Reynolds, Matthew R; Magnuson, Elizabeth A; Suri, Rakesh M; Tuzcu, E Murat; Petersen, John L; Douglas, Pamela S; Svensson, Lars G; Gada, Hemal; Thourani, Vinod H; Kodali, Susheel K; Mack, Michael J; Leon, Martin B; Cohen, David J

    2014-12-01

    In patients with severe aortic stenosis, transcatheter aortic valve replacement (TAVR) improves survival when compared with nonsurgical therapy but with higher in-hospital and lifetime costs. Complications associated with TAVR may decrease with greater experience and improved devices, thereby reducing the overall cost of the procedure. Therefore, we sought to estimate the effect of periprocedural complications on in-hospital costs and length of stay of TAVR. Using detailed cost data from 406 TAVR patients enrolled in the Placement of Aortic Transcatheter Valve (PARTNER) I trial, we developed multivariable models to estimate the incremental cost and length of stay associated with specific periprocedural complications. Attributable costs and length of stay for each complication were calculated by multiplying the independent cost of each event by its frequency in the treatment group. Mean cost for the initial hospitalization was $79 619±40 570 ($50 891 excluding the valve); 49% of patients had ≥1 complication. Seven complications were independently associated with increased hospital costs, with major bleeding, arrhythmia, and death accounting for the largest attributable cost per patient. Renal failure and the need for repeat TAVR, although less frequent, were also associated with substantial incremental and attributable costs. Overall, complications accounted for $12 475 per patient in initial hospital costs and 2.4 days of hospitalization. In the PARTNER trial, periprocedural complications were frequent, costly, and accounted for ≈25% of non-implant-related hospital costs. Avoidance of complications should improve the cost-effectiveness of TAVR for inoperable and high-risk patients, but reductions in the cost of uncomplicated TAVR will also be necessary for optimal efficiency. http://www.clinicaltrials.gov. Unique identifier: NCT00530894. © 2014 American Heart Association, Inc.

  17. Quantitative Gd-DOTA uptake from cerebrospinal fluid into rat brain using 3D VFA-SPGR at 9.4T.

    PubMed

    Lee, Hedok; Mortensen, Kristian; Sanggaard, Simon; Koch, Palle; Brunner, Hans; Quistorff, Bjørn; Nedergaard, Maiken; Benveniste, Helene

    2018-03-01

    We propose a quantitative technique to assess solute uptake into the brain parenchyma based on dynamic contrast-enhanced MRI (DCE-MRI). With this approach, a small molecular weight paramagnetic contrast agent (Gd-DOTA) is infused in the cerebral spinal fluid (CSF) and whole brain gadolinium concentration maps are derived. We implemented a 3D variable flip angle spoiled gradient echo (VFA-SPGR) longitudinal relaxation time (T1) technique, the accuracy of which was cross-validated by way of inversion recovery rapid acquisition with relaxation enhancement (IR-RARE) using phantoms. Normal Wistar rats underwent Gd-DOTA infusion into CSF via the cisterna magna and continuous MRI for approximately 130 min using T1-weighted imaging. Dynamic Gd-DOTA concentration maps were calculated and parenchymal uptake was estimated. In the phantom study, T1 discrepancies between the VFA-SPGR and IR-RARE sequences were approximately 6% with a transmit coil inhomogeneity correction. In the in vivo study, contrast transport profiles indicated maximal parenchymal retention of approximately 19% relative to the total amount delivered into the cisterna magna. Imaging strategies for accurate 3D contrast concentration mapping at 9.4T were developed and whole brain dynamic concentration maps were derived to study solute transport via the glymphatic system. The newly developed approach will enable future quantitative studies of the glymphatic system in health and disease states. Magn Reson Med 79:1568-1578, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  18. Quantitative 3-D imaging topogrammetry for telemedicine applications

    NASA Technical Reports Server (NTRS)

    Altschuler, Bruce R.

    1994-01-01

    The technology to reliably transmit high-resolution visual imagery over short to medium distances in real time has led to the serious considerations of the use of telemedicine, telepresence, and telerobotics in the delivery of health care. These concepts may involve, and evolve toward: consultation from remote expert teaching centers; diagnosis; triage; real-time remote advice to the surgeon; and real-time remote surgical instrument manipulation (telerobotics with virtual reality). Further extrapolation leads to teledesign and telereplication of spare surgical parts through quantitative teleimaging of 3-D surfaces tied to CAD/CAM devices and an artificially intelligent archival data base of 'normal' shapes. The ability to generate 'topogrames' or 3-D surface numerical tables of coordinate values capable of creating computer-generated virtual holographic-like displays, machine part replication, and statistical diagnostic shape assessment is critical to the progression of telemedicine. Any virtual reality simulation will remain in 'video-game' realm until realistic dimensional and spatial relational inputs from real measurements in vivo during surgeries are added to an ever-growing statistical data archive. The challenges of managing and interpreting this 3-D data base, which would include radiographic and surface quantitative data, are considerable. As technology drives toward dynamic and continuous 3-D surface measurements, presenting millions of X, Y, Z data points per second of flexing, stretching, moving human organs, the knowledge base and interpretive capabilities of 'brilliant robots' to work as a surgeon's tireless assistants becomes imaginable. The brilliant robot would 'see' what the surgeon sees--and more, for the robot could quantify its 3-D sensing and would 'see' in a wider spectral range than humans, and could zoom its 'eyes' from the macro world to long-distance microscopy. Unerring robot hands could rapidly perform machine-aided suturing with

  19. Effect of tricuspid regurgitation and the right heart on survival after transcatheter aortic valve replacement: insights from the Placement of Aortic Transcatheter Valves II inoperable cohort.

    PubMed

    Lindman, Brian R; Maniar, Hersh S; Jaber, Wael A; Lerakis, Stamatios; Mack, Michael J; Suri, Rakesh M; Thourani, Vinod H; Babaliaros, Vasilis; Kereiakes, Dean J; Whisenant, Brian; Miller, D Craig; Tuzcu, E Murat; Svensson, Lars G; Xu, Ke; Doshi, Darshan; Leon, Martin B; Zajarias, Alan

    2015-04-01

    Tricuspid regurgitation (TR) and right ventricular (RV) dysfunction adversely affect outcomes in patients with heart failure or mitral valve disease, but their impact on outcomes in patients with aortic stenosis treated with transcatheter aortic valve replacement has not been well characterized. Among 542 patients with symptomatic aortic stenosis treated in the Placement of Aortic Transcatheter Valves (PARTNER) II trial (inoperable cohort) with a Sapien or Sapien XT valve via a transfemoral approach, baseline TR severity, right atrial and RV size and RV function were evaluated by echocardiography according to established guidelines. One-year mortality was 16.9%, 17.2%, 32.6%, and 61.1% for patients with no/trace (n=167), mild (n=205), moderate (n=117), and severe (n=18) TR, respectively (P<0.001). Increasing severity of RV dysfunction as well as right atrial and RV enlargement were also associated with increased mortality (P<0.001). After multivariable adjustment, severe TR (hazard ratio, 3.20; 95% confidence interval, 1.50-6.82; P=0.003) and moderate TR (hazard ratio, 1.60; 95% confidence interval, 1.02-2.52; P=0.042) remained associated with increased mortality as did right atrial and RV enlargement, but not RV dysfunction. There was an interaction between TR and mitral regurgitation severity (P=0.04); the increased hazard of death associated with moderate/severe TR only occurred in those with no/trace/mild mitral regurgitation. In inoperable patients treated with transcatheter aortic valve replacement, moderate or severe TR and right heart enlargement are independently associated with increased 1-year mortality; however, the association between moderate or severe TR and an increased hazard of death was only found in those with minimal mitral regurgitation at baseline. These findings may improve our assessment of anticipated benefit from transcatheter aortic valve replacement and support the need for future studies on TR and the right heart, including whether

  20. 4D flow MRI assessment of extracranial-intracranial bypass: qualitative and quantitative evaluation of the hemodynamics.

    PubMed

    Sekine, Tetsuro; Takagi, Ryo; Amano, Yasuo; Murai, Yasuo; Orita, Erika; Matsumura, Yoshio; Kumita, Shin-Ichiro

    2016-03-01

    Our aim was to assess the feasibility of using time-resolved 3D phase-contrast (4D flow) MRI to characterize extracranial-intracranial (EC-IC) bypass. We enrolled 32 patients who underwent EC-IC bypass (15 men, 17 women; mean age 66.4 years). In all, 16 underwent radial artery graft (RAG) bypass and 16 underwent superficial temporal artery (STA) bypass. 4D flow MRI, time-of-flight (TOF) magnetic resonance angiography (MRA), and computed tomography angiography (CTA) were performed. Bypass patency, flow direction, and blood flow volume (BFV) of each artery were determined by 4D flow MRI. Arterial diameters were measured by TOF-MRA and CTA. We compared RAG and STA bypasses by evaluating the flow direction and BFV of each artery. We evaluated the correlation between arterial diameters (measured by CTA or MRA) and the BFV and the detectability of flow direction (measured by 4D flow MRI) of each artery. 4D flow MRI confirmed the patency of each bypass artery. Flow direction of the M1 segment of the middle cerebral artery and BFV in the bypass artery differed between RAG and STA groups (p < 0.01). BFV in the bypass slightly correlated with the diameters on CTA (p < 0.05, R (2) = 0.287). Of the 29 arteries in the circle of Willis, nine were not depicted on 4D flow MRI. Cutoff values for arterial diameters on CTA and TOF-MRA for detecting the artery on 4D flow MRI were 2.4 and 1.8 mm, respectively. 4D flow MRI provided unique information for characterizing EC-IC bypasses, although this detectability is limited when addressing small arteries with slow flow.

  1. Assessment of structural valve deterioration of transcatheter aortic bioprosthetic balloon-expandable valves using the new European consensus definition.

    PubMed

    Eltchaninoff, Hélène; Durand, Eric; Avinée, Guillaume; Tron, Christophe; Litzler, Pierre-Yves; Bauer, Fabrice; Dacher, Jean-Nicolas; Werhlin, Camille; Bouhzam, Najime; Bettinger, Nicolas; Candolfi, Pascal; Cribier, Alain

    2018-03-30

    Durability of transcatheter aortic bioprosthetic valves remains a major issue. Standardised definitions of deterioration and failure of bioprosthetic valves have recently been proposed. The aim of this study was to assess structural transcatheter valve deterioration (SVD) and bioprosthetic valve failure (BVF) using these new definitions. All TAVI patients implanted up to September 2012 with a minimal theoretical five-year follow-up were included. Systematic clinical and echocardiographic follow-up was performed annually. New standardised definitions were used to assess durability of transcatheter aortic bioprosthetic valves. From 2002 to 2012, 378 patients were included. Mean age and logistic EuroSCORE were 83.3±6.8 years and 22.8±13.1%. Thirty-day mortality was 13.2%. Nine patients had SVD including two severe forms and two patients had definite late BVF. The incidence of SVD and BVF at eight years was 3.2% (95% CI: 1.45-6.11) and 0.58% (95% CI: 0.15-2.75), respectively. Even though limited by the poor survival of the very high-risk/compassionate early population, our data do not demonstrate any alarm concerning transcatheter aortic valve durability. Careful prospective assessment in younger and lower-risk patients and comparison with surgical bioprosthetic valves are required for further assessment of the long-term durability of transcatheter valves.

  2. Transcatheter recanalization of ligated main pulmonary artery.

    PubMed

    Bhole, Vinay; Wright, John G C; Stumper, Oliver

    2007-04-01

    A 12.5-year-old boy with tricuspid atresia and quadriplegic cerebral palsy presented with increasing cyanosis after previous palliation with a cavopulmonary shunt and ligation of the main pulmonary artery (MPA). Because of severe physical disabilities he was not considered suitable for Fontan completion. He underwent successful transcatheter stent recanalization of the ligated MPA. This re-established anterograde flow to the pulmonary arteries resulting in marked improvement in saturations.

  3. Intracardiac echocardiography: use during transcatheter device closure of a patent ductus arteriosus in a dog.

    PubMed

    Chetboul, V; Damoiseaux, C; Behr, L; Morlet, A; Moise, N S; Gouni, V; Lavennes, M; Pouchelon, J-L; Laborde, F; Borenstein, N

    2017-06-01

    Intracardiac echocardiography (ICE) is used in humans for percutaneous interventional procedures, such as transcatheter device closures. Intracardiac echocardiography provides high-resolution imaging of cardiac structures with two-dimensional, M-mode, Doppler, and also three-dimensional modalities. The present report describes application of ICE during transcatheter occlusion of patent ductus arteriosus using a canine ductal occluder in a dog for which transesophageal echocardiography could not provide an optimal acoustic window. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Assisted care as a baseline patient risk characteristic affecting the outcome of transcatheter aortic valve insertion.

    PubMed

    Traynor, Megan M; Greason, Kevin L; Nkomo, Vuyisile T; Pochettino, Alberto; Holmes, David R; Rihal, Charanjit S; Reeder, Guy S; Bresnahan, John F; Mathew, Verghese

    2017-06-01

    Objective measures of frailty have not been well defined as risk factors for a poor outcome after transcatheter aortic valve insertion. We hypothesized that assisted care as a baseline patient characteristic was a simple objective measure of frailty. We reviewed our experience to assess for an association between assisted care and outcome of operation. We retrospectively reviewed the records of 597 patients operated with transcatheter aortic valve insertion from November 2008 through July 2015. The study cohort included patients with a dichotomous baseline characteristic of receiving assisted care (AC group, n = 60, 10.1%) or not receiving assisted care (NC group, n = 537, 89.9%). The endpoints of the study were operative stroke/death and 1-year survival. The age of the patients was 80.6 ± 9.0 years, male sex was present in 349 (58.5%), and STS predicted risk of mortality was 9.2 ± 6.2%. Alternate access was used in 26 (43.3%) patients in the AC care group and in 220 (41.0%) in the NC group (P = 0.724). Operative stroke/death occurred in 4 (6.7%) patients in the AC group and in 25 (4.7%) in the NC group (P = 0.492). Mortality at 1 year in the AC group was 14.8 ± 5.2% and in the NC group was 12.9 ± 1.7%; (P = 0. 250). Assisted care as a baseline patient characteristic does not result in increased operative stroke/death or 1-year mortality in patients following transcatheter aortic valve insertion. Assisted care should not by itself preclude operation. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  5. Clinical utility of simultaneous quantitation of 25-hydroxyvitamin D and 24,25-dihydroxyvitamin D by LC-MS/MS involving derivatization with DMEQ-TAD.

    PubMed

    Kaufmann, Martin; Gallagher, J Christopher; Peacock, Munro; Schlingmann, Karl-Peter; Konrad, Martin; DeLuca, Hector F; Sigueiro, Rita; Lopez, Borja; Mourino, Antonio; Maestro, Miguel; St-Arnaud, René; Finkelstein, Joel S; Cooper, Donald P; Jones, Glenville

    2014-07-01

    The discovery of hypercalcemic diseases due to loss-of-function mutations in 25-hydroxyvitamin D-24-hydroxylase has placed a new demand for sensitive and precise assays for 24,25-dihydroxyvitamin D [24,25-(OH)2D]. We describe a novel liquid chromatography and tandem mass spectrometry-based method involving derivatization with DMEQ-TAD {4-[2-(6,7-dimethoxy-4-methyl-3,4-dihydroquinoxalinyl)ethyl]-1,2,4-triazoline-3,5-dione} to simultaneously assay multiple vitamin D metabolites including 25-hydroxyvitamin D (25-OH-D) and 24,25-(OH)2D using 100 μL of serum with a 5-minute run time. The assay uses a newly synthesized internal standard d6-24,25-(OH)2D3 enabling the quantitation of 24,25-(OH)2D3 as well as the determination of the ratio of 25-OH-D3 to 24,25-(OH)2D3, a physiologically useful parameter. We report data on more than 1000 normal and disease samples involving vitamin D deficiency or hypercalcemia in addition to studies involving knockout mouse models. The assay showed good correlation with samples from quality assurance schemes for 25-OH-D (25-OH-D2 and 25-OH-D3) determination (-2% to -5% bias) and exhibited low inter- and intraassay coefficients of variation (4%-7%) and lower limits of quantitation of 0.25-0.45 nmol/L. In clinical studies, we found a strong correlation between serum levels of 25-OH-D3 and 24,25-(OH)2D3 (r(2) = 0.80) in subjects over a broad range of 25-OH-D3 values and a marked lack of production of 24,25-(OH)2D3 below 25 nmol/L of 25-OH-D. The ratio of 25-OH-D3 to 24,25-(OH)2D3, which remained less than 25 in vitamin D-sufficient subjects (serum 25-OH-D < 50 nmol/L) but was greatly elevated (80-100) in patients with idiopathic infantile hypercalcemia. The new method showed good utility in clinical settings involving vitamin D deficiency; supplementation with vitamin D and idiopathic infantile hypercalcemia, as well as in animal models with ablation of selected cytochrome P450-containing enzymes involved in vitamin D metabolism.

  6. Transcatheter correction of Scimitar syndrome: occlusion of abnormal pulmonary venous drainage and vascular supply in an infant.

    PubMed

    Saltik, Levent; Ugan Atik, Sezen; Bornaun, Helen

    2017-10-01

    Treatment of Scimitar syndrome is usually surgical; however, if there is "dual drainage" - that is, one to the inferior caval vein and the other to the left atrium - it is possible to successfully treat this anomaly via a less-invasive transcatheter approach. We report a case of Scimitar syndrome in a 21-month-old, male infant successfully treated with transcatheter embolisation.

  7. Staged transcatheter treatment of portal hypoplasia and congenital portosystemic shunts in children.

    PubMed

    Bruckheimer, Elchanan; Dagan, Tamir; Atar, Eli; Schwartz, Michael; Kachko, Ludmila; Superina, Riccardo; Amir, Gabriel; Shapiro, Rivka; Birk, Einat

    2013-12-01

    Congenital portosystemic shunts (CPSS) with portal venous hypoplasia cause hyperammonemia. Acute shunt closure results in portal hypertension. A transcatheter method of staged shunt reduction to afford growth of portal vessels followed by shunt closure is reported. Pressure measurements and angiography in the CPSS or superior mesenteric artery (SMA) during temporary occlusion of the shunt were performed. If vessels were diminutive and the pressure was above 18 mmHg, a staged approach was performed, which included implantation of a tailored reducing stent to reduce shunt diameter by ~50 %. Recatheterization was performed approximately 3 months later. If the portal pressure was below 18 mmHg and vessels had developed, the shunt was closed with a device. Six patients (5 boys, 1 girl) with a median age of 3.3 (range 0.5-13) years had CPSS portal venous hypoplasia and hyperammonemia. Five patients underwent staged closure. One patient tolerated acute closure. One patient required surgical shunt banding because a reducing stent could not be positioned. At median follow-up of 3.8 (range 2.2-8.4) years, a total of 21 procedures (20 transcatheter, 1 surgical) were performed. In all patients, the shunt was closed with a significant reduction in portal pressure (27.7 ± 11.3 to 10.8 ± 1.8 mmHg; p = 0.016), significant growth of the portal vessels (0.8 ± 0.5 to 4.0 ± 2.4 mm; p = 0.037), and normalization of ammonia levels (202.1 ± 53.6 to 65.7 ± 9.6 μmol/L; p = 0.002) with no complications. Staged CPSS closure is effective in causing portal vessel growth and treating hyperammonemia.

  8. The 4D nucleome project.

    PubMed

    Dekker, Job; Belmont, Andrew S; Guttman, Mitchell; Leshyk, Victor O; Lis, John T; Lomvardas, Stavros; Mirny, Leonid A; O'Shea, Clodagh C; Park, Peter J; Ren, Bing; Politz, Joan C Ritland; Shendure, Jay; Zhong, Sheng

    2017-09-13

    The 4D Nucleome Network aims to develop and apply approaches to map the structure and dynamics of the human and mouse genomes in space and time with the goal of gaining deeper mechanistic insights into how the nucleus is organized and functions. The project will develop and benchmark experimental and computational approaches for measuring genome conformation and nuclear organization, and investigate how these contribute to gene regulation and other genome functions. Validated experimental technologies will be combined with biophysical approaches to generate quantitative models of spatial genome organization in different biological states, both in cell populations and in single cells.

  9. Effects of transcatheter closure of Fontan fenestration on exercise tolerance. kidecho@yahoo.com.

    PubMed

    Momenah, Tarek S; Eltayb, Haifa; Oakley, Reida El; Qethamy, Howeida Al; Faraidi, Yahya Al

    2008-05-01

    Baffle fenestration is associated with a significantly better outcome in standard and high-risk patients undergoing completion of Fontan. We report the effects of subsequent transcatheter closure of fenestration on exercise capacity and oxygen saturation. Sixteen patients with a mean age of 10.3 years underwent Amplatzer septal occluder (ASO) device transcatheter closure of Fontan fenestration. All had a fenestrated Fontan operation 6 month to 8 years prior to the procedure. A stress test was performed before and after device closure of fenestration in 14 patients (2 patients did not tolerate stress test before the procedure). The fenestrations in all patients were successfully occluded with the use of the Amplatzer device occluder. No complications occurred during or after the procedure. O2 saturation increased from a mean 85.1 +/- 7.89% to 94.5 +/- 3.63% (p < 0.01) at rest and from 66.2 +/- 12.86% to 87.2 +/- 8.64% (p < 0.01) following exercise. Exercise duration has also increased from 8.22 +/- 2.74 min to 10.29 +/- 1.91 min (p < 0.05). Transcatheter closure of Fontan fenestration increases the duration of exercise capacity and increases O2 saturation at rest and after exercise.

  10. Salvaging catastrophe in transcatheter aortic valve implantation: rehearsal, preassigned roles, and emergency preparedness.

    PubMed

    Tam, Derrick Y; Jones, Philip M; Kiaii, Bob; Diamantouros, Pantelis; Teefy, Patrick; Bainbridge, Daniel; Cleland, Andrew; Fernandes, Philip; Chu, Michael W A

    2015-08-01

    Emergency rescue plans for acute complications during transcatheter aortic valve implantation (TAVI) commonly include cardiopulmonary resuscitation, femoro-femoral cardiopulmonary bypass (CPB), and hemodynamic stabilization before definitive intervention is achieved. Nevertheless, most cases of emergency resuscitation remain chaotic and disorganized and often take longer than necessary, even in experienced centres. We sought to determine which factors and procedures may be associated with improved patient outcomes when emergencies arise during TAVI. MEDLINE(®) and EMBASE™ were searched with the following key words: "TAVI" or "TAVR" or "transcatheter valve implantation" or "transcatheter valve replacement" and "emergency cardiac surgery" or "conversion". Two hundred seventeen articles met the criteria and were reviewed. Utilization of a formal emergency checklist by a multidisciplinary TAVI team may reduce procedural errors, smooth the transition to CPB, and ultimately speed the delivery of corrective measures including emergency cardiac surgery. A well-organized regularly-rehearsed emergency rescue plan that preassigns resuscitative roles may shorten the duration of patient instability and resuscitation and improve patient outcomes when catastrophe occurs in TAVI. The anesthesia team plays a central role in preventing, detecting, and treating intraprocedural complications during TAVI.

  11. Comparison of long-term clinical outcome between transcatheter Amplatzer occlusion and surgical closure of isolated patent ductus arteriosus.

    PubMed

    Chen, Zhao-yang; Wu, Li-ming; Luo, Yu-kun; Lin, Chao-gui; Peng, Ya-fei; Zhen, Xing-chun; Chen, Liang-long

    2009-05-20

    Transcatheter Amplatzer occlusion of patent ductus artertiosus (PDA) has emerged as a minimally invasive alternative to surgical closure. The goal of this study was to compare long-term clinical outcomes between two procedures, especially on chronic residual shunt, late or very late procedure-related complications, and regression of pulmonary hypertension and left ventricular dilation. A total 255 patients having isolated PDA with a minimal diameter of >or= 4 mm treated from January 2000 to July 2003 were included in this study and have been followed up until July 2008. The patients were assigned to either the device or surgical closure group according to the patients' and/or their parents' preference. Baseline physical exams, chest roentgenography, electrocardiography, and echocardiography were performed preprocedure and at each follow-up. Seventy-two patients accepted the transcatheter procedure (Group-TC) and 183 underwent surgical operation (Group-SO) for PDA closure, both groups were similar in their demographics and preoperative clinical characteristics. There were no cardiac deaths and late complications such as infectious endocarditis and Amplatzer duct occluder (ADO) dislodge in either group. More acute procedure-related complications were recorded in Group-SO (13.7%) compared with Group-TC (1.4%) (P = 0.004). The recovery time was (8.7 +/- 2.3) days for the Group-SO and (1.3 +/- 0.5) days for the Group-TC (P < 0.001). The survival freedom from persistent residual shunt, defined as residual shunt that can not resolve automatically, was 91.3% for Group-SO and 98.6% for Group-TC (P = 0.037 by Log-rank test). There was no significant difference in regression of pulmonary hypertension and left ventricular dilation; neither survival freedom from pulmonary hypertension nor abnormal left ventricular end-diastolic volume index were significantly different between the surgical group and the Amplatzer group. Our study confirmed the long-term safety and efficacy of

  12. Pre-procedural assessment of aortic annulus dimensions for transcatheter aortic valve replacement: comparison of a non-contrast 3D MRA protocol with contrast-enhanced cardiac dual-source CT angiography.

    PubMed

    Ruile, Philipp; Blanke, Philipp; Krauss, Tobias; Dorfs, Stephan; Jung, Bernd; Jander, Nikolaus; Leipsic, Jonathon; Langer, Mathias; Neumann, Franz-Josef; Pache, Gregor

    2016-04-01

    To evaluate the feasibility of a non-contrast three-dimensional (3D)-FLASH magnetic resonance angiography (MRA) protocol for pre-procedural aortic annulus assessment for transcatheter aortic valve replacement (TAVR) in comparison with cardiac dual-source computed tomography angiography (CTA). In this prospective study, 69 of 104 consecutive patients (mean age 81.8 ± 5.4 years, 37.7% arrhythmic) with severe aortic stenosis who had undergone pre-TAVR cardiac CTA received a respiratory and ECG-triggered, non-contrast 3D-FLASH MRA at 3 T. Annular area measurements were obtained at mid-diastole for both modalities whereas maximum systolic area was assessed by CTA only. Systolic MRA dimensions were modelled, by adding the relative difference of systolic and diastolic CTA area dimensions as a corrective factor. Hypothetical prosthesis sizing was performed based on systolic CTA, diastolic, and modelled systolic MRA area measurements. MR image quality and degree of annular calcifications were evaluated using 4-point-grading scales. The mean acquisition time was 14 ± 4.2 min. The mean image quality was 3.1 ± 0.9 with only two examinations rated non-diagnostic. The mean degree of calcifications was equal. As assessed by Bland-Altman analysis, there was no relevant systematic difference between area measurements for modelled systolic MRA and systolic CTA [the mean difference -3.1 mm(2) (limits of agreement -44.4 mm(2); 38.2 mm(2))]. Agreement for hypothetical prosthesis sizing was found in 63 of 67 (94%) patients for systolic CTA and modelled systolic MRA. The employed non-contrast 3D-FLASH MRA protocol allows for reliable assessment of aortic annulus dimensions and calcifications even in the presence of arrhythmias in an all-comers pre-TAVR population. Implementation of this technique appears legitimate in patients at an increased risk for contrast-induced nephropathy. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For

  13. Advanced transcatheter aortic valve implantation (TAVI) planning from CT with ShapeForest.

    PubMed

    Swee, Joshua K Y; Grbić, Saša

    2014-01-01

    Transcatheter aortic valve implantation (TAVI) is becoming a standard treatment for non-operable and high-risk patients with symptomatic severe aortic valve stenosis. As there is no direct view or access to the affected anatomy, comprehensive preoperative planning is crucial for a successful outcome, with the most important decisions made during planning being the selection of the proper implant size, and determining the correct C-arm angulations. While geometric models extracted from 3D images are often used to derive these measurements, the complex shape variation of the AV anatomy found in these patients causes many of the shape representations used to estimate such geometric models to fail in capturing morphological characteristics in sufficient detail. In addition, most current approaches only model the aortic valve (AV), omitting modeling the left ventricle outflow tract (LVOT) entirely despite its high correlation with severe complications such as annulus ruptures, paravalvular leaks and myocardial infarction. We propose a fully automated method to extract patient specific models of the AV and the LVOT, and derive comprehensive biomarkers for accurate TAVI planning. We utilize a novel shape representation--the ShapeForest--which is able to model complex shape variation, preserves local shape information, and incorporates prior knowledge during shape space inference. Extensive quantitative and qualitative experiments performed on 630 volumetric data sets demonstrate an accuracy of 0.69 mm for the AV and 0.83 mm for the LVOT, an improvement of over 16% and 18% respectively when compared against state of the art methods.

  14. Next-Generation Transcatheter Heart Valves: Current Trials in Europe and the USA

    PubMed Central

    Werner, Nikos; Nickenig, Georg

    2012-01-01

    Transcatheter aortic valve implantation (TAVI) has proven to be a viable alternative for patients with symptomatic severe aortic stenosis who are at high risk for surgical aortic valve replacement. At the same time, there is increasing evidence that moderate-to-severe periprosthetic aortic regurgitation after TAVI is associated with dramatically increased mortality and morbidity. The issue of proper positioning of the valve, including the ability to reposition and recapture the device, must be dealt with before the use of TAVI can be extended to younger, healthier patients. The next generation of transcatheter heart valves will most likely address repositionability to facilitate accurate placement with additional features that minimize paravalvular leakage. Upcoming devices promise to improve outcomes and usability of current TAVI systems. PMID:22891121

  15. [Life-threatening hemoptysis. Treatment with transcatheter embolization].

    PubMed

    Gimeno Peribáñez, M J; Madariaga, B; Alfonso Aguirán, E R; Medrano Peña, J; Fernández Gómez, J A; Herrera, M; de Gregorio Ariza, M A

    1999-09-01

    To evaluate the immediate and long-term efficacy of transcatheter embolization of bronchial, systemic and pulmonary arteries to treat life-threatening hemoptysis. Likewise, we propose the systematic treatment of life-threatening hemoptysis by means of transcatheter embolization. One hundred seven angiographies were performed on the same number of patients experiencing life-threatening hemoptysis with bleeding exceeding 150 ml in 24 hours. Before angiography, we rinsed the vessels with cold saline solution and adrenalin through the catheter. Thirty-three patients were female and 74 were male. Mean age was 52.3 years (range 12 to 75 years). Embolization was performed in 104 (3 in patients with recurrent hemoptysis) using polyvinyl alcohol and micro-coils. Bronchial and systemic arteries of the affected hemithorax (mammary and lateral thoracic arteries) were checked in all patients. If findings were negative or bleeding was recurrent, we also performed pulmonary arteriography. In two cases we were unable to catheterize the artery theoretically responsible for bleeding. Examination of both arterial and systemic vessels proved normal in one patient. The embolization technique was successful in 99% (103/104) of the cases and the rate of immediate clinical success was 95.1% (99/104). The mean time of follow-up was 43.2 months (range 3 to 66 months). Hemoptysis recurred in 15.3% (16 cases) within a mean 8.3 months (range 15 days to 48 months); embolization was repeated in 14 of these patients with satisfactory results, while two underwent surgery. In five patients (4.8%) we observed complications requiring no additional medical treatment: one instance of coil migration to the deep femoral artery, from which the coil was removed in a basket; two cases of bronchial artery extravasation with small mediastinal hematomas; and two hematomas at the points of puncture. Selective or supra-selective embolization of the arteries that feed the bronchi provides effective management of

  16. Clinical Utility of Simultaneous Quantitation of 25-Hydroxyvitamin D and 24,25-Dihydroxyvitamin D by LC-MS/MS Involving Derivatization With DMEQ-TAD

    PubMed Central

    Kaufmann, Martin; Gallagher, J. Christopher; Peacock, Munro; Schlingmann, Karl-Peter; Konrad, Martin; DeLuca, Hector F.; Sigueiro, Rita; Lopez, Borja; Mourino, Antonio; Maestro, Miguel; St-Arnaud, René; Finkelstein, Joel S.; Cooper, Donald P.

    2014-01-01

    Context: The discovery of hypercalcemic diseases due to loss-of-function mutations in 25-hydroxyvitamin D-24-hydroxylase has placed a new demand for sensitive and precise assays for 24,25-dihydroxyvitamin D [24,25-(OH)2D]. Objective: We describe a novel liquid chromatography and tandem mass spectrometry-based method involving derivatization with DMEQ-TAD {4-[2-(6,7-dimethoxy-4-methyl-3,4-dihydroquinoxalinyl)ethyl]-1,2,4-triazoline-3,5-dione} to simultaneously assay multiple vitamin D metabolites including 25-hydroxyvitamin D (25-OH-D) and 24,25-(OH)2D using 100 μL of serum with a 5-minute run time. Design: The assay uses a newly synthesized internal standard d6-24,25-(OH)2D3 enabling the quantitation of 24,25-(OH)2D3 as well as the determination of the ratio of 25-OH-D3 to 24,25-(OH)2D3, a physiologically useful parameter. Setting: We report data on more than 1000 normal and disease samples involving vitamin D deficiency or hypercalcemia in addition to studies involving knockout mouse models. Results: The assay showed good correlation with samples from quality assurance schemes for 25-OH-D (25-OH-D2 and 25-OH-D3) determination (−2% to −5% bias) and exhibited low inter- and intraassay coefficients of variation (4%–7%) and lower limits of quantitation of 0.25–0.45 nmol/L. In clinical studies, we found a strong correlation between serum levels of 25-OH-D3 and 24,25-(OH)2D3 (r2 = 0.80) in subjects over a broad range of 25-OH-D3 values and a marked lack of production of 24,25-(OH)2D3 below 25 nmol/L of 25-OH-D. The ratio of 25-OH-D3 to 24,25-(OH)2D3, which remained less than 25 in vitamin D-sufficient subjects (serum 25-OH-D < 50 nmol/L) but was greatly elevated (80–100) in patients with idiopathic infantile hypercalcemia. Conclusions: The new method showed good utility in clinical settings involving vitamin D deficiency; supplementation with vitamin D and idiopathic infantile hypercalcemia, as well as in animal models with ablation of selected cytochrome P

  17. A Systematic Review of Acquired Uterine Arteriovenous Malformations: Pathophysiology, Diagnosis, and Transcatheter Treatment

    PubMed Central

    Yoon, Daniel J.; Jones, Megan; Taani, Jamal Al; Buhimschi, Catalin; Dowell, Joshua D.

    2015-01-01

    Objective An acquired uterine arteriovenous malformation (AVM) is a rare cause of vaginal bleeding and, although hysterectomy is the definitive therapy, transcatheter embolization (TCE) provides an alternative treatment option. This systematic review presents the indications, technique, and outcomes for transcatheter treatment of the acquired uterine AVMs. Study Design Literature databases were searched from 2003 to 2013 for eligible clinical studies, including the patient characteristics, procedural indication, results, complications, as well as descriptions on laterality and embolic agents utilized. Results A total of 40 studies were included comprising of 54 patients (average age of 33.4 years). TCE had a primary success rate with symptomatic control of 61% (31 patients) and secondary success rate of 91% after repeated embolization. When combined with medical therapy, symptom resolution was noted in 48 (85%) patients without more invasive surgical procedures. Conclusion Low-level evidence supports the role of TCE, including in the event of persistent bleeding following initial embolization, for the treatment of acquired uterine AVMs. The variety of embolic agents and laterality of approach delineate the importance of refining procedural protocols in the treatment of the acquired uterine AVM. Condensation A review on the management of patients with acquired uterine AVMs. PMID:26929872

  18. Transcatheter Arterial Embolization for Spontaneous Rupture of the Omental Artery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matsumoto, Tomohiro, E-mail: t-matsu@koto.kpu-m.ac.jp; Yamagami, Takuji; Morishita, Hiroyuki

    We encountered a rare case of spontaneous rupture of the omental artery. A 25-year-old man without any episode of abdominal trauma or bleeding disorders came to the emergency unit with left upper abdominal pain. Hematoma with extravasation of the greater omentum and a hemoperitoneum was confirmed on abdominal contrast-enhanced computed tomography. Bleeding from the omental artery was suspected based on these findings. Transcatheter arterial embolization was successfully performed after extravasation of the omental artery, which arises from the left gastroepiploic artery, was confirmed on arteriography. Partial ometectomy was performed 10 days after transcatheter arterial embolization, revealing that the hematoma measuredmore » 10 cm in diameter in the greater omentum. Pathological examination showed rupture of the branch of an omental artery without abnormal findings, such as an aneurysm or neoplasm. Thus, we diagnosed him with spontaneous rupture of the omental artery. The patient recovered and was discharged from the hospital 10 days after the surgery, with a favorable postoperative course.« less

  19. Quantitative detection of 4-hydroxyequilenin-DNA adducts in mammalian cells using an immunoassay with a novel monoclonal antibody.

    PubMed

    Okahashi, Yumiko; Iwamoto, Takaaki; Suzuki, Naomi; Shibutani, Shinya; Sugiura, Shigeki; Itoh, Shinji; Nishiwaki, Tomohisa; Ueno, Satoshi; Mori, Toshio

    2010-07-01

    Estrogen-DNA adducts are potential biomarkers for assessing the risk and development of estrogen-associated cancers. 4-Hydroxyequilenin (4-OHEN) and 4-hydroxyequilin (4-OHEQ), the metabolites of equine estrogens present in common hormone replacement therapy (HRT) formulations, are capable of producing bulky 4-OHEN-DNA adducts. Although the formation of 4-OHEN-DNA adducts has been reported, their quantitative detection in mammalian cells has not been done. To quantify such DNA adducts, we generated a novel monoclonal antibody (4OHEN-1) specific for 4-OHEN-DNA adducts. The primary epitope recognized is one type of stereoisomers of 4-OHEN-dA adducts and of 4-OHEN-dC adducts in DNA. An immunoassay with 4OHEN-1 revealed a linear dose-response between known amounts of 4-OHEN-DNA adducts and the antibody binding to those adducts, with a detection limit of approximately five adducts/10(8) bases in 1 microg DNA sample. In human breast cancer cells, the quantitative immunoassay revealed that 4-OHEN produces five times more 4-OHEN-DNA adducts than does 4-OHEQ. Moreover, in a mouse model for HRT, oral administration of Premarin increased the levels of 4-OHEN-DNA adducts in various tissues, including the uterus and ovaries, in a time-dependent manner. Thus, we succeeded in establishing a novel immunoassay for quantitative detection of 4-OHEN-DNA adducts in mammalian cells.

  20. The 4D Nucleome Project

    PubMed Central

    Dekker, Job; Belmont, Andrew S.; Guttman, Mitchell; Leshyk, Victor O.; Lis, John T.; Lomvardas, Stavros; Mirny, Leonid A.; O’Shea, Clodagh C.; Park, Peter J.; Ren, Bing; Ritland Politz, Joan C.; Shendure, Jay; Zhong, Sheng

    2017-01-01

    Preface The 4D Nucleome Network aims to develop and apply approaches to map the structure and dynamics of the human and mouse genomes in space and time with the goal of gaining deeper mechanistic understanding of how the nucleus is organized and functions. The project will develop and benchmark experimental and computational approaches for measuring genome conformation and nuclear organization, and investigate how these contribute to gene regulation and other genome functions. Validated experimental approaches will be combined with biophysical modeling to generate quantitative models of spatial genome organization in different biological states, both in cell populations and in single cells. PMID:28905911

  1. Staged Transcatheter Treatment of Portal Hypoplasia and Congenital Portosystemic Shunts in Children

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bruckheimer, Elchanan, E-mail: elchananb@bezeqint.net; Dagan, Tamir; Atar, Eli

    2013-12-15

    Purpose: Congenital portosystemic shunts (CPSS) with portal venous hypoplasia cause hyperammonemia. Acute shunt closure results in portal hypertension. A transcatheter method of staged shunt reduction to afford growth of portal vessels followed by shunt closure is reported. Methods: Pressure measurements and angiography in the CPSS or superior mesenteric artery (SMA) during temporary occlusion of the shunt were performed. If vessels were diminutive and the pressure was above 18 mmHg, a staged approach was performed, which included implantation of a tailored reducing stent to reduce shunt diameter by {approx}50 %. Recatheterization was performed approximately 3 months later. If the portal pressuremore » was below 18 mmHg and vessels had developed, the shunt was closed with a device. Results: Six patients (5 boys, 1 girl) with a median age of 3.3 (range 0.5-13) years had CPSS portal venous hypoplasia and hyperammonemia. Five patients underwent staged closure. One patient tolerated acute closure. One patient required surgical shunt banding because a reducing stent could not be positioned. At median follow-up of 3.8 (range 2.2-8.4) years, a total of 21 procedures (20 transcatheter, 1 surgical) were performed. In all patients, the shunt was closed with a significant reduction in portal pressure (27.7 {+-} 11.3 to 10.8 {+-} 1.8 mmHg; p = 0.016), significant growth of the portal vessels (0.8 {+-} 0.5 to 4.0 {+-} 2.4 mm; p = 0.037), and normalization of ammonia levels (202.1 {+-} 53.6 to 65.7 {+-} 9.6 {mu}mol/L; p = 0.002) with no complications. Conclusion: Staged CPSS closure is effective in causing portal vessel growth and treating hyperammonemia.« less

  2. Simultaneous transcatheter therapy for perimembranous ventricular septal defect combined with patent ductus arteriosus.

    PubMed

    Wang, Qiguang; Zhu, Xianyang; Duanzhen, Zhang; Zhang, Po; Chen, Huoyuan; Han, Xiumin; Sheng, Xiaotang; Meng, Lili

    2017-06-01

    This study aims to assess the clinical efficiency and safety of simultaneous transcatheter interventional treatment for perimembranous ventricular septal defect (pmVSD) combined with patent ductus arteriosus (PDA). Twenty-five patients with pmVSD and PDA treated with simultaneous transcatheter interventions from April 2004 to December 2015 were included in this study. The mean age was 9.80 ± 8.14 years and the mean weight was 29.76 ± 14.82 Kg. Transthoracic echocardiography (TTE) and angiography were performed immediately after the procedure. Patients were re-examined by electrocardiogram, X-ray, and TTE at 2 days, 1 month, 3 months, and 6 months postoperatively. The interventional procedure was successfully performed in all 25 patients. No intraoperative complication was noted. TTE examination of the VSD and PDA immediately after the procedure showed no residual shunt and the occluder was well positioned. Among these patients, four patients showed electrocardiogram changes after the procedure that resolved after drug therapy. The cardiothoracic ratio, left atrial diameter, left ventricular end-systolic diameter, and left ventricular end-diastolic diameter recovered to normal in most patients at 6 months postoperatively. Simultaneously transcatheter interventional therapy is a safe and effective method for pmVSD combined with PDA. © 2017 Wiley Periodicals, Inc.

  3. [Successful transcatheter ablation of fascicular potential in pediatric patients with left posterior fascicular tachycardia].

    PubMed

    Zeng, Shao-ying; Shi, Ji-jun; Li, Hong; Zhang, Zhi-wei; Li, Yu-fen

    2010-08-01

    To simplify the methods of transcatheter mapping and ablation in the pediatric patients with left posterior fascicular tachycardia. While in sinus rhythm, the fascicular potential can be mapped at the posterior septal region (1 - 2 cm below inferior margin of orifice of coronary sinus vein), which display a biphasic wave before ventricular wave, and exist equipotential lines between them. When the fascicular potential occurs 20 ms later than the bundle of His' potential, radiofrequency was applied. Before applying radiofrequency, catheter position must be observed using double angle viewing (LAO 45°RAO 30°), and it should be made sure that the catheter is not at His' bundle. If the electrocardiogram displays left posterior fascicular block, the correct region is identified and ablation can continue for 60 s. Electrocardiogram monitoring should continue for 24 - 48 hours after operation, and notice abnormal repolarization after termination of ventricular tachycardia. Aspirin [2 - 3 mg/(kg·d)] was used for 3 months, and antiarrhythmic drug was discontinued. Surface electrocardiogram, chest X-ray and ultrasound cardiography were rechecked 1 d after operation. Follow-up was made at 1 month and 3 months post-discharge. Recheck was made half-yearly or follow-up was done by phone from then on. Fifteen pediatric patients were ablated successfully, and their electrocardiograms all displayed left posterior fascicular block after ablation. None of the patients had recurrences during the 3 to 12 months follow-up period. In one case, the electrocardiogram did not change after applying radiofrequency ablation and the ventricular tachycardia remained; however, on second attempt after remapping, the electrocardiogram did change. The radiofrequency lasted for 90 seconds and ablation was successful. This case had no recurrences at 6 months follow-up. Transcatheter ablation of the fascicular potential in pediatric patients with left posterior fascicular tachycardia can simplify

  4. Progression of Treated versus Untreated Liver Imaging Reporting and Data System Category 4 Masses after Transcatheter Arterial Embolization Therapy.

    PubMed

    Ronald, James; Gupta, Rajan T; Marin, Daniele; Wang, Qi; Durocher, Nicholas S; Suhocki, Paul V; Kim, Charles Y

    2018-05-01

    To compare outcomes of treated vs untreated Liver Imaging Reporting and Data System category 4 (LR-4) masses after transcatheter arterial embolization. In 167 patients undergoing embolization for HCC from January 2005 to December 2012, LR-4 masses were retrospectively identified on CT and MR imaging examinations performed before embolization. In 149 patients undergoing embolization from January 2013 to December 2016, masses prospectively classified as LR-4 were identified. In total, there were 81 LR-4 masses in 62 patients (16 women; mean age 62 y; range 29-83 y). Procedures were reviewed to determine whether LR-4 masses were within or outside the liver volume that received embolization during treatment of dominant masses. Time to progression to LR-5 and by modified Response Evaluation Criteria in Solid Tumors (mRECIST) was estimated for treated vs untreated LR-4 masses using the Kaplan-Meier method and compared using the log rank test. LR-4 masses averaged 1.8 cm; 88%, 60%, 14%, and 14% demonstrated arterial phase hyperenhancement, washout, a capsule, and growth. Of LR-4 masses, 62 were within the liver volume that received embolization and considered treated, and 19 were outside and considered untreated. Response rates according to mRECIST were 37% vs 21% for treated vs untreated masses (P = .27). The 6- and 12-month rates of progression to LR-5 were 7% and 26% for treated masses vs 27% and 75% for untreated masses (P = .001). According to mRECIST, 7% and 27% of treated masses progressed vs 30% and 65% of untreated masses (P = .001). LR-4 masses that receive embolization in the setting of dominant masses elsewhere show lower rates of progression compared with untreated masses. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  5. [Analysis and follow-up study on 8 children with combined congenital heart disease treated with simultaneous trans-catheter therapy].

    PubMed

    Cheng, Sheng-Quan; Liu, Jian-Ping; Sun, Xin; Li, Jun; Zhang, Jun; Liu, Li-Wen; Deng, Yue-Lin; Niu, Yong-Chun

    2008-10-01

    Interventional treatment for childhood combined congenital heart disease (CHD) has developed very quickly and more new types of occluders have emerged in recent years. The aim of this study is to investigate the efficiency and safety of interventional treatment for combined CHD in children. Eight children with combined CHD (4 boys and 4 girls), aged 6.1+/-2.9 years, underwent simultaneous transcatheter therapy. Of the 8 children with CHD, 1 case had atrial septal defect (ASD), ventricular septal defect (VSD) and patent ductus arteriosus (PDA), 1 case had ASD, PDA and pulmonary stenosis (PS), 1 case had ASD and PDA, 1 case had patent foramen ovale (PFO) and PS, and 4 cases had ASD and PS. The methods of transcatheter intervention for these patients were as follows: in patients with ASD,VSD and PDA, the occlusion of VSD was performed first, followed by PDA and ASD occlusions; in patients with ASD, PDA and PS, the occlusion of percutaneous balloon pulmonary valvuloplasty (PBPV) was performed first, followed by PDA and ASD occlusions; in patients with PFO and PS, the occlusion of PBPV was performed first, and PFO occlusion followed; in patients with ASD and PS, the occlusion of PBPV was performed first, and ASD occlusion followed. The intervention operation was successfully performed in all of the 8 patients. No serious adverse events occurred during the operation. No residual shunt was found and all the occlusion devices were in the suitable sites shown by transthoracic echocardiography (TTE) and X-ray right after the operation. In the 6 patients with PS, the systolic pressure across the pulmonary valve decreased from 75.3+/-15.6 mmHg (before operation) to 14.0+/-5.6 mmHg after operation (P<0.05).A 3.4+/-1.2 years follow-up demonstrated that no residual shunt occurred and gradients across valve or coarctation sites were within the limit of satisfactory results. No complications were observed during the follow-up. Transcatheter interventional therapy for childhood

  6. Long-Term Results of Transcatheter Closure of Patent Ductus Arteriosus in Infants Using Amplatzer Duct Occluder

    PubMed Central

    Behjati-Ardakani, Mostafa; Behjati-Ardakani, Mohammad-Amin; Hosseini, Seyed-Habibolla; Noori, Noormohammad

    2013-01-01

    Objective Patent ductus arteriosus (PDA) is one of the most frequently seen congenital heart diseases. Its closure is recommended because of the risk of infective endocardis, as well as morbidity and mortality in the long. The aim of this study was to assess the long term results of the transcatheter closure of PDA in infants using amplatzer duct occlude (ADO). Methods From May 2004 to September 2011, forty eight infants underwent transcatheter closure of PDA. A lateral or right anterior oblique view aortogram was done to locate PDA and to measure its size. Before discharge, repeat aortogram was performed to evaluate eventual residual shunt and to confirm the appropriate deployment of the ADO. Follow up evaluations were done with transthoracic echocardiography at discharge, 1 month, 6 months, 12 months and yearly thereafter. Findings The mean age of patients at procedure was 9.18±2.32 (range 3 to 12) months, mean weight 6.73±1.16 (range 4.5 to 10.1) kg. The PDA occluded completely in 20 out of the 48 patients. Twenty four patients had trivial or mild shunt and two patients had moderate residual shunt which disappeared in one patient within 24 hours and other patient with moderate shunt in 1 month. One patient (age 8 months) had mild LPA stenosis. The device emobolization occurred in two patients, immediately after the procedure in one and during night in the other patient Conclusion The long term results suggested that transcatheter closure of PDA using Amplatzer duct occluder is a safe and effective treatment in infants less than 1 year of age with minimal complications. PMID:24427494

  7. AN ENZYME LINKED IMMUNOSORBENT ASSAY (ELISA) METHOD FOR MONITORING 2,4 DICHLOROPHENOXYACETIC ACID (2,4-D) EXPOSURES

    EPA Science Inventory

    Abstract describes a streamlined ELISA method developed to quantitatively measure 2,4-D in human urine samples. Method development steps and comparison with gas chromatography/mass spectrometry are presented. Results indicated that the ELISA method could be used as a high throu...

  8. AN ENZYME LINKED IMMUNOSORBENT ASSAY (ELISA) METHOD FOR THE URINARY BIOMONITORING OF 2,4-DICHLOROPHRENOCYACETIC ACID (2,4-D)

    EPA Science Inventory

    An enzyme-linked immunosorbent assay (ELISA) method was developed to quantitatively measure 2,4-dichlorophenoyacetic acid (2,4-D) in human urine. Samples were diluted (1:5) with phosphate-buffered saline, 0.05% Tween 20, with 0.02% sodium azide, and analyzed by a 96-microwekk pl...

  9. Cracking a tricuspid perimount bioprosthesis to optimize a second transcatheter sapien valve-in-valve placement.

    PubMed

    Brown, Stephen C; Cools, Bjorn; Gewillig, Marc

    2016-09-01

    Bioprosthetic valves degenerate over time. Transcatheter valve-in-valve procedures have become an attractive alternative to surgery. However, every valve increasingly diminishes the diameter of the valvar orifice. We report a 12-year-old female who had a previous transcatheter tricuspid valve-in-valve procedure; cracking the ring of a Carpentier Edwards Perimount valve by means of an ultrahigh pressure balloon allowed implantation of a further larger percutaneous valve. The advantage of this novel approach permits enlarging the inner valve diameter and may facilitate future interventions and prolong time to surgery. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  10. Transcatheter occlusion of the patent ductus arteriosus in premature infants weighing less than 1200 g.

    PubMed

    Morville, Patrice; Douchin, Stephanie; Bouvaist, Helene; Dauphin, Claire

    2018-05-01

    Over the last few decades different strategies have been proposed to treat persistent ductal patency in premature infants. The advent of the Amplatzer Duct Occluder II Additional Size (ADOIIAS) provided the potential to close the patent ductus arteriosus (PDA). Opinions differ on the significance and treatment of PDA in premature neonates. Because surgical ligation and medical therapy both have their drawbacks, interventional catheterisation can be considered as an alternative means of closing the ductus arteriosus. Our aim was to analyse the feasibility, safety and efficacy of this device in premature infants weighing <1200 g at procedure. Eighteen premature infants underwent transcatheter closure. The procedure was performed in the catheterisation laboratory by venous cannulation without angiography. The position of the occluder was directed by X-ray and ultrasound. We looked at procedural details, device size selection, complications and short-term and mid-term outcomes. Eighteen infants born at gestational ages ranging between 23.6 and 29+6 weeks (mean±SD 25+6±3 weeks) underwent transcatheter PDA closure. Their mean age and weight at the time of the procedure was 20 days (range 8-44 days) and 980 g (range 680-1200 g), respectively. The mean PDA and device waist diameters were 3.2±0.6 mm (range 2.2-4 mm) and 4.5±0.6 mm, respectively, and the mean PDA and device lengths were 4.3±1.2 mm (range 2-10 mm) and 2.5±0.9 mm, respectively. Complete closure was achieved in all but one patient. There was no device migration. One patient developed a left pulmonary artery obstruction. Three infants died. Two deaths were related to complications of prematurity and one to the procedure. Transcatheter closure of a PDA is feasible in very low weight infants with ADOIIAS and is an alternative to surgery. Success requires perfect selection and placement of the occluder. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article

  11. 3D Slicer as an Image Computing Platform for the Quantitative Imaging Network

    PubMed Central

    Fedorov, Andriy; Beichel, Reinhard; Kalpathy-Cramer, Jayashree; Finet, Julien; Fillion-Robin, Jean-Christophe; Pujol, Sonia; Bauer, Christian; Jennings, Dominique; Fennessy, Fiona; Sonka, Milan; Buatti, John; Aylward, Stephen; Miller, James V.; Pieper, Steve; Kikinis, Ron

    2012-01-01

    Quantitative analysis has tremendous but mostly unrealized potential in healthcare to support objective and accurate interpretation of the clinical imaging. In 2008, the National Cancer Institute began building the Quantitative Imaging Network (QIN) initiative with the goal of advancing quantitative imaging in the context of personalized therapy and evaluation of treatment response. Computerized analysis is an important component contributing to reproducibility and efficiency of the quantitative imaging techniques. The success of quantitative imaging is contingent on robust analysis methods and software tools to bring these methods from bench to bedside. 3D Slicer is a free open source software application for medical image computing. As a clinical research tool, 3D Slicer is similar to a radiology workstation that supports versatile visualizations but also provides advanced functionality such as automated segmentation and registration for a variety of application domains. Unlike a typical radiology workstation, 3D Slicer is free and is not tied to specific hardware. As a programming platform, 3D Slicer facilitates translation and evaluation of the new quantitative methods by allowing the biomedical researcher to focus on the implementation of the algorithm, and providing abstractions for the common tasks of data communication, visualization and user interface development. Compared to other tools that provide aspects of this functionality, 3D Slicer is fully open source and can be readily extended and redistributed. In addition, 3D Slicer is designed to facilitate the development of new functionality in the form of 3D Slicer extensions. In this paper, we present an overview of 3D Slicer as a platform for prototyping, development and evaluation of image analysis tools for clinical research applications. To illustrate the utility of the platform in the scope of QIN, we discuss several use cases of 3D Slicer by the existing QIN teams, and we elaborate on the future

  12. Transcatheter closure of left ventricle to right atrial communication using cera duct occluder.

    PubMed

    Ganesan, Gnanavelu; Paul, G Justin; Mahadevan, Vaikom S

    Left ventricle-right atrial communication could be congenital (Gerbode defect) or acquired as a complication of surgery or infective endocarditis and leads to volume overloading of pulmonary circulation. Two types, direct and indirect types are known depending on the involvement of septal tricuspid leaflet. Transcatheter closure of this defect is feasible and appears an attractive alternative to surgical management. Various devices like Amplatzer duct occluder I, II, Muscular ventricular septal defect device etc. have been used to close this defect. We report two patients, a preteen boy with direct left ventricle-right atrial communication as post operative complication and an adult female with indirect communication who underwent transcatheter closure with Cera duct occluder (Lifetech Scientific (Shenzhen), China). Copyright © 2017. Published by Elsevier B.V.

  13. Transcatheter closure of atrial septal defect with amplatzer septal occluder in adults: immediate, short, and intermediate-term results.

    PubMed

    Behjati, Mostafa; Rafiei, Mansour; Soltani, Mohammad Hossein; Emami, Mahmoud; Dehghani, Majid

    2011-01-01

    The transcatheter closure of the atrial septal defect (ASD) has become an alternative technique to surgical procedures. The aim of this study was to assess the immediate, short, and intermediate-term results of the transcatheter closure of the secundum ASD with the Amplatzer Septal Occluder (ASO) in adult Iranian patients. Between December 2004 and July 2008, the transcatheter closure of the ASD using the ASO was attempted in 58 consecutive, adult patients. The mean age of the patients was 37.1 ± 12.7 years (range = 19 - 75 years). All the procedures were performed under local anesthesia with transthoracic or transesophageal echocardiography and fluoroscopic guidance. The stretched diameter of the ASD was determined with a balloon sizing catheter, and device selection was based on and matched to the stretched diameter of the septal defect. Transthoracic echocardiography was performed immediately after the release of the device and before discharge. Further follow-up at one month, six months, and yearly thereafter included physical examination, electrocardiography, and transthoracic echocardiography. The mean ASD diameter, as measured by esophageal echocardiography, was 24.8 ± 5.4 mm (range = 13 - 34 mm). The mean stretched diameter, as measured by the balloon catheter, was 27.1 ± 6.4 mm (range = 12.5 - 39 mm). Deployment of the ASO was successful in 52 (89.6%) patients and failed in 6 (10.4%). Four patients experienced severe complications, 1 had tamponade requiring drainage, 2 had device embolization to the left atrium and right ventricular outflow tract, and 1 had late wire fracture (surgical removal and repair of the ASD). The position of two large devices (34 mm and 36 mm) was considered unsuitable and unstable after implantation and resulted in the removal of these devices. Minor complications included transient complete atrioventricular block in 1 patient, paroxysmal supra tachycardia in 3 patients, atrial flutter in 1 patient, and angina pectoris with

  14. Computational Fluid Dynamics Assessment Associated with Transcatheter Heart Valve Prostheses: A Position Paper of the ISO Working Group.

    PubMed

    Wei, Zhenglun Alan; Sonntag, Simon Johannes; Toma, Milan; Singh-Gryzbon, Shelly; Sun, Wei

    2018-04-19

    The governing international standard for the development of prosthetic heart valves is International Organization for Standardization (ISO) 5840. This standard requires the assessment of the thrombus potential of transcatheter heart valve substitutes using an integrated thrombus evaluation. Besides experimental flow field assessment and ex vivo flow testing, computational fluid dynamics is a critical component of this integrated approach. This position paper is intended to provide and discuss best practices for the setup of a computational model, numerical solving, post-processing, data evaluation and reporting, as it relates to transcatheter heart valve substitutes. This paper is not intended to be a review of current computational technology; instead, it represents the position of the ISO working group consisting of experts from academia and industry with regards to considerations for computational fluid dynamic assessment of transcatheter heart valve substitutes.

  15. Helical 4D CT and Comparison with Cine 4D CT

    NASA Astrophysics Data System (ADS)

    Pan, Tinsu

    4D CT was one of the most important developments in radiation oncology in the last decade. Its early development in single slice CT and commercialization in multi-slice CT has radically changed our practice in radiation treatment of lung cancer, and has enabled the stereotactic radiosurgery of early stage lung cancer. In this chapter, we will document the history of 4D CT development, detail the data sufficiency condition governing the 4D CT data collection; present the design of the commercial helical 4D CTs from Philips and Siemens; compare the differences between the helical 4D CT and the GE cine 4D CT in data acquisition, slice thickness, acquisition time and work flow; review the respiratory monitoring devices; and understand the causes of image artifacts in 4D CT.

  16. Triple shape memory polymers by 4D printing

    NASA Astrophysics Data System (ADS)

    Bodaghi, M.; Damanpack, A. R.; Liao, W. H.

    2018-06-01

    This article aims at introducing triple shape memory polymers (SMPs) by four-dimensional (4D) printing technology and shaping adaptive structures for mechanical/bio-medical devices. The main approach is based on arranging hot–cold programming of SMPs with fused decomposition modeling technology to engineer adaptive structures with triple shape memory effect (SME). Experiments are conducted to characterize elasto-plastic and hyper-elastic thermo-mechanical material properties of SMPs in low and high temperatures at large deformation regime. The feasibility of the dual and triple SMPs with self-bending features is demonstrated experimentally. It is advantageous in situations either where it is desired to perform mechanical manipulations on the 4D printed objects for specific purposes or when they experience cold programming inevitably before activation. A phenomenological 3D constitutive model is developed for quantitative understanding of dual/triple SME of SMPs fabricated by 4D printing in the large deformation range. Governing equations of equilibrium are established for adaptive structures on the basis of the nonlinear Green–Lagrange strains. They are then solved by developing a finite element approach along with an elastic-predictor plastic-corrector return map procedure accomplished by the Newton–Raphson method. The computational tool is applied to simulate dual/triple SMP structures enabled by 4D printing and explore hot–cold programming mechanisms behind material tailoring. It is shown that the 4D printed dual/triple SMPs have great potential in mechanical/bio-medical applications such as self-bending gripers/stents and self-shrinking/tightening staples.

  17. Is the new Occlutech duct occluder an appropriate device for transcatheter closure of patent ductus arteriosus?

    PubMed

    Godart, François; Houeijeh, Ali; Domanski, Olivia; Guillaume, Marie-Paule; Brard, Mélanie; Lucron, Hugues

    2018-06-15

    To describe our initial experience with the Occlutech Duct Occluder (ODO) for percutaneous closure of patent ductus arteriosus (PDA). Retrospective review of patients undergoing transcatheter PDA closure with the ODO in 2 academic centers. From April 2013 to September 2017, 42 patients underwent PDA closure. Median age at implantation was 34 months (range 4 months-68 years) and median weight was 12 kg (range 4.1-57 kg). Ducts were Krichenko type A duct (n = 34), type E (n = 6), and type C (n = 2). The mean duct diameter was 3.76 mm (range 1.69 to 9.95 mm, median 3.1 mm). Implantation succeeded in all. There was neither device embolization nor hemolysis. At device release, immediate angiogram showed a small residual shunt in 54.7%. During follow-up, Doppler echocardiography demonstrated 71% of full occlusion at day one, rising to 95% at one month and 100% at one year and half after implantation. The mean maximal systolic pressure gradient in left pulmonary artery was 4.2 ± 4.3 mm and across the distal aortic arch 5.4 ± 4.7 mm Hg. No patient had any significant stenosis with clinical relevance. ODO is safe and effective in transcatheter closure of PDA including relatively large sized ducts. The results are satisfactory with a high level of full occlusion and a low rate of complications. Further evaluation with larger studies and longer follow-up will be required to confirm these preliminary good results. Copyright © 2018. Published by Elsevier B.V.

  18. Transcatheter closure of patent ductus arteriosus with severe pulmonary arterial hypertension in adults.

    PubMed

    Yan, C; Zhao, S; Jiang, S; Xu, Z; Huang, L; Zheng, H; Ling, J; Wang, C; Wu, W; Hu, H; Zhang, G; Ye, Z; Wang, H

    2007-04-01

    Surgical closure of patent ductus arteriosus (PDA) with severe pulmonary arterial hypertension in adults carries higher risk than in children. To investigate the application of self-expandable occluders for transcatheter closure of PDA associated with severe pulmonary arterial hypertension in adults, and the assessment of immediate and short-term results. 29 adult patients (6 men, 23 women) underwent attempted transcatheter closure of PDA at a mean (standard deviation (SD)) age of 31.1 (11.4) years (range 18-58 years) and a mean (SD) weight of 54.1 (7.1) kg (range 42-71 kg). On the basis of haemodynamic and clinical data obtained before and after trial occlusion, the final duct occlusion was determined and carried out. Radiographs of the chest, electrocardiograms and echocardiograms were used for follow-up evaluation of the treatment within 1 day, 1 month and 3-6 months after successful closure. 20 of the 29 patients had successful occlusion (group 1), and 9 patients failed (named group 2). In group 1, in which occlusion was successful, mean (SD) pulmonary arterial pressures decreased markedly after trial occlusion: 78 (19.3) mm Hg (range 50-125 mm Hg) before occlusion and 41 (13.8) mm Hg (range 23-77 mm Hg) after occlusion. Systemic arterial oxygen saturation was found to be >90% in 19 patients and <90% in the remaining patient before inhalation of oxygen, and >95% during inhalation of oxygen or after occlusion in all 20 patients. In group 2, the occlusion was not successful, because in two patients the device was not available; another two patients showed worsening of symptoms. The other five patients showed increased pulmonary arterial pressures after trial closure; their mean (SD) pulmonary arterial pressures increased by 10.3 (6) mm Hg (4-16 mm Hg) after trial occlusion, and systemic arterial oxygen saturation was 85.5% (2.6%) (range 82.6-88%) before inhalation of oxygen and 94.7% (1.7%) (range 90.7-99.1%) during inhalation of oxygen. In group 1, the

  19. Ex vivo hydrodynamics after central and paracommissural edge-to-edge technique: A further step toward transcatheter tricuspid repair?

    PubMed

    Stock, Sina; Bohm, Heidemarie; Scharfschwerdt, Michael; Richardt, Doreen; Meyer-Saraei, Roza; Tsvelodub, Stanislav; Sievers, Hans-Hinrich

    2018-03-01

    Transcatheter approaches in heart valve disease became tremendously important and are currently established in the aortic position, but transcatheter tricuspid repair is still in its beginning and remains challenging. Replicating the surgical edge-to-edge technique, for example, with the MitraClip System (Abbott Vascular, Santa Clara, Calif), represents a promising option and has been reported successfully in small numbers of cases. However, up to now, few data considering the edge-to-edge technique as a transcatheter approach are available. This study aims to determine the ex vivo hydrodynamics after the central and paracommissural edge-to-edge technique in different pathologies. Because of basal or apical dislocation of papillary muscles, leaflet prolapse or tethering was simulated in porcine tricuspid valves mounted on a flexible holding device. Central and paracommissural edge-to-edge techniques were evaluated successively in these pathologies. Regurgitant volume and mean transvalvular gradient were determined in a pulse duplicator. In this ex vivo model, the isolated edge-to-edge technique reduced tricuspid regurgitation. In the prolapse model, regurgitant volume decreased significantly after central edge-to-edge technique (from 49.4 ± 13.6 mL/stroke to 39.3 ± 14.1 mL/stroke). In the tethering model, both the central and the paracommissural edge-to-edge techniques led to a significant decrease (from 48.7 ± 13.9 to 43.6 ± 15.6 and to 41.1 ± 13.8 mL/stroke). In all cases, the reduction of regurgitant volume was achieved at the cost of significantly increased mean transvalvular gradient. This study provides a reduction of tricuspid regurgitation after the edge-to-edge technique in the specific experimental setup. Whether this reduction is sufficient to treat tricuspid regurgitation successfully in clinical practice remains to be established. Transcatheter approaches need to be evaluated further, probably with regard to concomitant annuloplasty

  20. Multiplex, quantitative cellular analysis in large tissue volumes with clearing-enhanced 3D microscopy (Ce3D)

    PubMed Central

    Li, Weizhe; Germain, Ronald N.

    2017-01-01

    Organ homeostasis, cellular differentiation, signal relay, and in situ function all depend on the spatial organization of cells in complex tissues. For this reason, comprehensive, high-resolution mapping of cell positioning, phenotypic identity, and functional state in the context of macroscale tissue structure is critical to a deeper understanding of diverse biological processes. Here we report an easy to use method, clearing-enhanced 3D (Ce3D), which generates excellent tissue transparency for most organs, preserves cellular morphology and protein fluorescence, and is robustly compatible with antibody-based immunolabeling. This enhanced signal quality and capacity for extensive probe multiplexing permits quantitative analysis of distinct, highly intermixed cell populations in intact Ce3D-treated tissues via 3D histo-cytometry. We use this technology to demonstrate large-volume, high-resolution microscopy of diverse cell types in lymphoid and nonlymphoid organs, as well as to perform quantitative analysis of the composition and tissue distribution of multiple cell populations in lymphoid tissues. Combined with histo-cytometry, Ce3D provides a comprehensive strategy for volumetric quantitative imaging and analysis that bridges the gap between conventional section imaging and disassociation-based techniques. PMID:28808033

  1. Transapical implantation of a second-generation transcatheter heart valve in patients with noncalcified aortic regurgitation.

    PubMed

    Seiffert, Moritz; Diemert, Patrick; Koschyk, Dietmar; Schirmer, Johannes; Conradi, Lenard; Schnabel, Renate; Blankenberg, Stefan; Reichenspurner, Hermann; Baldus, Stephan; Treede, Hendrik

    2013-06-01

    This study sought to report on the feasibility and early results of transcatheter aortic valve implantation employing a second-generation device in a series of patients with pure aortic regurgitation. Efficacy and safety of transcatheter aortic valve implantation in patients with calcific aortic stenosis and high surgical risk has been demonstrated. However, experience with implantation for severe noncalcified aortic regurgitation has been limited due to increased risk for valve dislocation or annular rupture. Five patients (mean age: 66.6 ± 7 years) underwent transapical implantation of a JenaValve (JenaValve Technology GmbH, Munich, Germany) transcatheter heart valve for moderate to severe, noncalcified aortic regurgitation. All patients were considered high risk for surgical aortic valve replacement after evaluation by an interdisciplinary heart team (logistic EuroSCORE [European System for Cardiac Operative Risk Evaluation] range 3.1% to 38.9%). Procedural and acute clinical outcomes were analyzed. Implantation was successful in all cases without relevant remaining aortic regurgitation or signs of stenosis in any of the patients. No major device- or procedure-related adverse events occurred and all 5 patients were alive with improved exercise tolerance at 3-month follow-up. Noncalcified aortic regurgitation continues to be a challenging pathology for transcatheter aortic valve implantation due to the risk for insufficient anchoring of the valve stent within the aortic annulus. This report provides first evidence that the JenaValve prosthesis may be a reasonable option in these specific patients due to its unique stent design, clipping the native aortic valve leaflets, and offering promising early results. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  2. Clinical Outcomes Following Transcatheter Aortic Valve Replacement in Asian Population.

    PubMed

    Yoon, Sung-Han; Ahn, Jung-Min; Hayashida, Kentaro; Watanabe, Yusuke; Shirai, Shinichi; Kao, Hsien-Li; Yin, Wei-Hsian; Lee, Michael Kang-Yin; Tay, Edgar; Araki, Motoharu; Yamanaka, Futoshi; Arai, Takahide; Lin, Mao-Shin; Park, Jun-Bean; Park, Duk-Woo; Kang, Soo-Jin; Lee, Seung-Whan; Kim, Young-Hak; Lee, Cheol Whan; Park, Seong-Wook; Muramatsu, Toshiya; Hanyu, Michiya; Kozuma, Ken; Kim, Hyo-Soo; Saito, Shigeru; Park, Seung-Jung

    2016-05-09

    This study describes the characteristics of a real-world Asian patient population treated with transcatheter aortic valve replacement (TAVR) and evaluates their clinical outcomes. No previously reported randomized or observational studies adequately assess the safety and efficacy of TAVR in an Asian population. The Asian TAVR registry is an international multicenter study that enrolled patients with aortic stenosis who underwent TAVR in Asian countries. In total, 848 patients with mean STS score of 5.2 ± 3.8% were enrolled between March 2010 and September 2014 at 11 centers in 5 countries. The Edwards Sapien or Medtronic CoreValve was implanted in 64.7% and 35.3% of patients, respectively. The procedural success rate was 97.5%. The 30-day and 1-year mortality rates were 2.5% and 10.8%, respectively. There was no difference in 1-year mortality between devices (Sapien: 9.4%; CoreValve: 12.2%; log-rank p = 0.40). The rates of stroke, life-threatening bleeding, major vascular complications and acute kidney injury (stage 2 to 3) were 3.8%, 6.4%, 5.0% and 3.3%, respectively. Moderate or severe paravalvular leakage was significantly more common with the CoreValve than Sapien (14.4% vs. 7.3%; p = 0.001). According to the multivariate model, a higher STS score, lower body mass index, New York Heart Association functional class III-IV symptoms, diabetes mellitus, prior cerebrovascular accident, low mean gradient at baseline, and moderate or severe paravalvular leakage were significantly associated with reduced survival. Despite anatomical features of concern, the clinical outcomes of TAVR in our Asian population were favorable in comparison with those of previously published trials and observational studies. (The Asian Transcatheter Aortic Valve Replacement Registry [Asian TAVR]; NCT02308150). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  3. Aortic root segmentation in 4D transesophageal echocardiography

    NASA Astrophysics Data System (ADS)

    Chechani, Shubham; Suresh, Rahul; Patwardhan, Kedar A.

    2018-02-01

    The Aortic Valve (AV) is an important anatomical structure which lies on the left side of the human heart. The AV regulates the flow of oxygenated blood from the Left Ventricle (LV) to the rest of the body through aorta. Pathologies associated with the AV manifest themselves in structural and functional abnormalities of the valve. Clinical management of pathologies often requires repair, reconstruction or even replacement of the valve through surgical intervention. Assessment of these pathologies as well as determination of specific intervention procedure requires quantitative evaluation of the valvular anatomy. 4D (3D + t) Transesophageal Echocardiography (TEE) is a widely used imaging technique that clinicians use for quantitative assessment of cardiac structures. However, manual quantification of 3D structures is complex, time consuming and suffers from inter-observer variability. Towards this goal, we present a semiautomated approach for segmentation of the aortic root (AR) structure. Our approach requires user-initialized landmarks in two reference frames to provide AR segmentation for full cardiac cycle. We use `coarse-to-fine' B-spline Explicit Active Surface (BEAS) for AR segmentation and Masked Normalized Cross Correlation (NCC) method for AR tracking. Our method results in approximately 0.51 mm average localization error in comparison with ground truth annotation performed by clinical experts on 10 real patient cases (139 3D volumes).

  4. Transcatheter closure of a large patent ductus arteriosus in a young child using the Amplatzer duct occluder.

    PubMed

    Jan, S-L; Hwang, B; Fu, Y-C; Chi, C-S

    2005-01-01

    The Amplatzer duct occluder (ADO) provides a safe and effective therapy for patients with moderate- to large-sized patent ductus arteriosus (PDA), but there have been few reports of transcatheter closure of very large PDAs in young children and infants. We report a successful transcatheter closure of a very large PDA, 10.5 mm in diameter at the narrowest point, with a 14/12-mm ADO. To our knowledge, this is the largest PDA ever closed by an interventional method in such a young child.

  5. Vortex flow during early and late left ventricular filling in normal subjects: quantitative characterization using retrospectively-gated 4D flow cardiovascular magnetic resonance and three-dimensional vortex core analysis.

    PubMed

    Elbaz, Mohammed S M; Calkoen, Emmeline E; Westenberg, Jos J M; Lelieveldt, Boudewijn P F; Roest, Arno A W; van der Geest, Rob J

    2014-09-27

    LV diastolic vortex formation has been suggested to critically contribute to efficient blood pumping function, while altered vortex formation has been associated with LV pathologies. Therefore, quantitative characterization of vortex flow might provide a novel objective tool for evaluating LV function. The objectives of this study were 1) assess feasibility of vortex flow analysis during both early and late diastolic filling in vivo in normal subjects using 4D Flow cardiovascular magnetic resonance (CMR) with retrospective cardiac gating and 3D vortex core analysis 2) establish normal quantitative parameters characterizing 3D LV vortex flow during both early and late ventricular filling in normal subjects. With full ethical approval, twenty-four healthy volunteers (mean age: 20±10 years) underwent whole-heart 4D Flow CMR. The Lambda2-method was used to extract 3D LV vortex ring cores from the blood flow velocity field during early (E) and late (A) diastolic filling. The 3D location of the center of vortex ring core was characterized using cylindrical cardiac coordinates (Circumferential, Longitudinal (L), Radial (R)). Comparison between E and A filling was done with a paired T-test. The orientation of the vortex ring core was measured and the ring shape was quantified by the circularity index (CI). Finally, the Spearman's correlation between the shapes of mitral inflow pattern and formed vortex ring cores was tested. Distinct E- and A-vortex ring cores were observed with centers of A-vortex rings significantly closer to the mitral valve annulus (E-vortex L=0.19±0.04 versus A-vortex L=0.15±0.05; p=0.0001), closer to the ventricle's long-axis (E-vortex: R=0.27±0.07, A-vortex: R=0.20±0.09, p=0.048) and more elliptical in shape (E-vortex: CI=0.79±0.09, A-vortex: CI=0.57±0.06; <0.001) compared to E-vortex. The circumferential location and orientation relative to LV long-axis for both E- and A-vortex ring cores were similar. Good to strong correlation was found

  6. Human monoclonal macroglobulins with specificity for Klebsiella K polysaccharides that contain 3,4-pyruvylated-D-galactose and 4,6- pyruvylated-D-galactose

    PubMed Central

    1980-01-01

    Two human IgM myeloma proteins, IgMWEA and IgMMAY, were found to react with agar and Klebsiella polysaccharides that contain pyruvylated D- galactose (DGal). Quantitative precipitin data and precipitin inhibition studies with methyl alpha- and beta-glycosides of 4,6- pyruvylated-D-galactose showed their combining sites to be different, although each was directed against the pyruvylated-D-Gal, one reacting most specifically with Klebsiella polysaccharides with terminal nonreducing beta-linked 2,4 pyruvylated-D-Gal, whereas the other reacted equally well with Klebsiella polysaccharides that contain 3,4 beta-linked and 4,6 alpha-linked terminal nonreducing pyruvylated-DGal. Inhibition studies showed that both sites are directed toward one of the two space isomers of 3,4- or 4,6-pyruvylated DGal, the form in which the methyl group of the pyruvate is equatorial, or endo, and its carboxyl group axial, or exo, to the plane of the acetal ring. Coprecipitation studies showed the combining site of IgMWEA to be located on an (Fab')2 fragment and not on the (Fc)5mu fragment. The monoclonal peak in the serum of IgMMAY was specifically precipitated by Klebsiella polysaccharide. Myeloma proteins with specificities of this type may occur with reasonable frequency in humans and may be a consequence of clonal expansion from inapparent infection, carrier states, or disease produced by various Klebsiella organisms. PMID:6158553

  7. Conscious Sedation Versus General Anesthesia in Transcatheter Aortic Valve Replacement: The German Aortic Valve Registry.

    PubMed

    Husser, Oliver; Fujita, Buntaro; Hengstenberg, Christian; Frerker, Christian; Beckmann, Andreas; Möllmann, Helge; Walther, Thomas; Bekeredjian, Raffi; Böhm, Michael; Pellegrini, Costanza; Bleiziffer, Sabine; Lange, Rüdiger; Mohr, Friedrich; Hamm, Christian W; Bauer, Timm; Ensminger, Stephan

    2018-03-26

    The aims of this study were to report on the use of local anesthesia or conscious sedation (LACS) and general anesthesia in transcatheter aortic valve replacement and to analyze the impact on outcome. Transcatheter aortic valve replacement can be performed in LACS or general anesthesia. Potential benefits of LACS, such as faster procedures and shorter hospital stays, need to be balanced with safety. A total of 16,543 patients from the German Aortic Valve Registry from 2011 to 2014 were analyzed, and propensity-matched analyses were performed to correct for potential selection bias. LACS was used in 49% of patients (8,121 of 16,543). In hospital, LACS was associated with lower rates of low-output syndrome, respiratory failure, delirium, cardiopulmonary resuscitation, and death. There was no difference in paravalvular leakage (II+) between LACS and general anesthesia in the entire population (5% vs. 4.8%; p = 0.76) or in the matched population (3.9% vs. 4.9%, p = 0.13). The risk for prolonged intensive care unit stay (≥3 days) was significantly reduced with LACS (odds ratio: 0.82; 95% confidence interval [CI]: 0.73 to 0.92; p = 0.001). Thirty-day mortality was lower with LACS in the entire population (3.5% vs. 4.9%; hazard ratio [HR]: 0.72; 95% CI: 0.60 to 0.86; p < 0.001) and in the matched population (2.8% vs. 4.6%; HR: 0.6; 95% CI: 0.45 to 0.8; p < 0.001). However, no differences in 1-year mortality between both groups in the entire population (16.5% vs. 16.9%; HR: 0.93; 95% CI: 0.85 to 1.02; p = 0.140) and in the propensity-matched population (14.1% vs. 15.5%; HR: 0.90; 95% CI: 0.78 to 1.03; p = 0.130) were observed. Use of LACS in transcatheter aortic valve replacement is safe, with fewer post-procedural complications and lower early mortality, suggesting its broad application. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  8. Whole-body PET parametric imaging employing direct 4D nested reconstruction and a generalized non-linear Patlak model

    NASA Astrophysics Data System (ADS)

    Karakatsanis, Nicolas A.; Rahmim, Arman

    2014-03-01

    Graphical analysis is employed in the research setting to provide quantitative estimation of PET tracer kinetics from dynamic images at a single bed. Recently, we proposed a multi-bed dynamic acquisition framework enabling clinically feasible whole-body parametric PET imaging by employing post-reconstruction parameter estimation. In addition, by incorporating linear Patlak modeling within the system matrix, we enabled direct 4D reconstruction in order to effectively circumvent noise amplification in dynamic whole-body imaging. However, direct 4D Patlak reconstruction exhibits a relatively slow convergence due to the presence of non-sparse spatial correlations in temporal kinetic analysis. In addition, the standard Patlak model does not account for reversible uptake, thus underestimating the influx rate Ki. We have developed a novel whole-body PET parametric reconstruction framework in the STIR platform, a widely employed open-source reconstruction toolkit, a) enabling accelerated convergence of direct 4D multi-bed reconstruction, by employing a nested algorithm to decouple the temporal parameter estimation from the spatial image update process, and b) enhancing the quantitative performance particularly in regions with reversible uptake, by pursuing a non-linear generalized Patlak 4D nested reconstruction algorithm. A set of published kinetic parameters and the XCAT phantom were employed for the simulation of dynamic multi-bed acquisitions. Quantitative analysis on the Ki images demonstrated considerable acceleration in the convergence of the nested 4D whole-body Patlak algorithm. In addition, our simulated and patient whole-body data in the postreconstruction domain indicated the quantitative benefits of our extended generalized Patlak 4D nested reconstruction for tumor diagnosis and treatment response monitoring.

  9. Recanalization of Splenic Artery Aneurysm After Transcatheter Arterial Embolization Using N-Butyl Cyanoacrylate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matsumoto, Keiji; Ushijima, Yasuhiro, E-mail: ushijima@radiol.med.kyushu-u.ac.jp; Tajima, Tsuyoshi

    2010-02-15

    A 65-year-old woman who had been diagnosed as having microscopic polyangiitis developed sudden abdominal pain and entered a state of shock. Abdominal CT showed massive hemoperitoneum, and emergent angiography revealed a ruptured splenic artery aneurysm. After direct catheterization attempts failed due to tortuous vessels and angiospasm, transcatheter arterial embolization using an n-butyl cyanoacrylate (NBCA)-lipiodol mixture was successfully performed. Fifty days later, the patient developed sudden abdominal pain again. Repeated angiography demonstrated recanalization of the splenic artery and splenic artery aneurysm. This time, the recanalized aneurysm was embolized using metallic coils with the isolation method. Physicians should keep in mind thatmore » recanalization can occur after transcatheter arterial embolization using N-butyl cyanoacrylate, which has been used as a permanent embolic agent.« less

  10. Percutaneous coronary intervention in patients with severe aortic stenosis: implications for transcatheter aortic valve replacement.

    PubMed

    Goel, Sachin S; Agarwal, Shikhar; Tuzcu, E Murat; Ellis, Stephen G; Svensson, Lars G; Zaman, Tarique; Bajaj, Navkaranbir; Joseph, Lee; Patel, Neil S; Aksoy, Olcay; Stewart, William J; Griffin, Brian P; Kapadia, Samir R

    2012-02-28

    With the availability of transcatheter aortic valve replacement, management of coronary artery disease in patients with severe aortic stenosis (AS) is posing challenges. Outcomes of percutaneous coronary intervention (PCI) in patients with severe AS and coronary artery disease remain unknown. We sought to compare the short-term outcomes of PCI in patients with and without AS. From our PCI database, we identified 254 patients with severe AS who underwent PCI between 1998 and 2008. Using propensity matching, we found 508 patients without AS who underwent PCI in the same period. The primary end point of 30-day mortality after PCI was similar in patients with and without severe AS (4.3% [11 of 254] versus 4.7% [24 of 508]; hazard ratio, 0.93; 95% confidence interval, 0.51-1.69; P=0.2). Patients with low ejection fraction (≤30%) and severe AS had a higher 30-day post-PCI mortality compared with those with an ejection fraction >30% (5.4% [7 of 45] versus 1.2% [4 of 209]; P<0.001). In addition, AS patients with high Society of Thoracic Surgeons score (≥10) had a higher 30-day post-PCI mortality than those with a Society of Thoracic Surgeons score <10 (10.4% [10 of 96] versus 0%; P<0.001). PCI can be performed in patients with severe symptomatic AS and coronary artery disease without an increased risk of short-term mortality compared with propensity-matched patients without AS. Patients with ejection fraction ≤30% and Society of Thoracic Surgeons score ≥10% are at a highest risk of 30-day mortality after PCI. This finding has significant implications in the management of severe coronary artery disease in high-risk severe symptomatic AS patients being considered for transcatheter aortic valve replacement.

  11. Application of 3D and 2D quantitative shear wave elastography (SWE) to differentiate between benign and malignant breast masses.

    PubMed

    Tian, Jie; Liu, Qianqi; Wang, Xi; Xing, Ping; Yang, Zhuowen; Wu, Changjun

    2017-01-20

    As breast cancer tissues are stiffer than normal tissues, shear wave elastography (SWE) can locally quantify tissue stiffness and provide histological information. Moreover, tissue stiffness can be observed on three-dimensional (3D) colour-coded elasticity maps. Our objective was to evaluate the diagnostic performances of quantitative features in differentiating breast masses by two-dimensional (2D) and 3D SWE. Two hundred ten consecutive women with 210 breast masses were examined with B-mode ultrasound (US) and SWE. Quantitative features of 3D and 2D SWE were assessed, including elastic modulus standard deviation (E SD E ) measured on SWE mode images and E SD U measured on B-mode images, as well as maximum elasticity (E max ). Adding quantitative features to B-mode US improved the diagnostic performance (p < 0.05) and reduced false-positive biopsies (p < 0.0001). The area under the receiver operating characteristic curve (AUC) of 3D SWE was similar to that of 2D SWE for E SD E (p = 0.026) and E SD U (p = 0.159) but inferior to that of 2D SWE for E max (p = 0.002). Compared with E SD U , E SD E showed a higher AUC on 2D (p = 0.0038) and 3D SWE (p = 0.0057). Our study indicates that quantitative features of 3D and 2D SWE can significantly improve the diagnostic performance of B-mode US, especially 3D SWE E SD E , which shows considerable clinical value.

  12. Transcatheter closure of post-operative residual ventricular septal defect using a patent ductus arteriosus closure device in an adult: a case report.

    PubMed

    Djer, Mulyadi M; Idris, Nikmah S; Alwi, Idrus; Wijaya, Ika P

    2014-07-01

    Transcatheter closure of perimembranous and muscular ventricular septal defect (VSD) has been performed widely and it has more advantages compare to surgery. However, transcatheter closure of residual VSD post operation of complex congenital heart disease is still challenging because of the complexity of anatomy and concern about device stability, so the operator should meticulously choose the most appropriate technique and device. We would like to report a case of transcatheter closure of residual VSD post Rastelli operation in a patient with double outlet right ventricle (DORV), sub-aortic VSD, severe infundibulum pulmonary stenosis (PS) and single coronary artery. The patient had undergone operations for four times, but he still had intractable heart failure that did not response to medications. On the first attempt. we closed the VSD using a VSD occluder, unfortunately the device embolized into the descending aorta, but fortunately we was able to snare it out. Then we decided to close the VSD using a patent ductus arteriosus (PDA occluder). On transesophageal echocardiography (TEE) and angiography evaluation, the device position was stable. Post transcatheter VSD closure, the patient clinical condition improved significantly and he could finally be discharged after a long post-surgery hospitalization. Based on this experience we concluded that the transcatheter closure of residual VSD in complex CHD using PDA occluder could be an effective alternative treatment.

  13. Fenestrated Transcatheter ASD Closure in Adults with Diastolic Dysfunction and/or Pulmonary Hypertension: Case Series and Review of the Literature.

    PubMed

    Abdelkarim, Ayman; Levi, Daniel S; Tran, Bao; Ghobrial, Joanna; Aboulhosn, Jamil

    2016-12-01

    This study aims to evaluate the safety and efficacy of transcatheter fenestrated ASD closure and to summarize the literature regarding the published techniques and outcomes of transcatheter partial ASD closure. Patients with left ventricular diastolic dysfunction (LVDD) or right ventricular (RV) dysfunction and/or pulmonary hypertension (PHT) may suffer untoward consequences of complete closure of an ostium secundum atrial septal defect (ASD). Therefore, for patients that fall under these categories we suggest partial occlusion of the defect, which may be better tolerated than complete defect closure. After obtaining IRB approval, a search for patients that have undergone percutaneous ASD closure was performed in the Ahmanson/UCLA Adult Congenital Heart Disease Center database to identify which patients received a fenestrated ASD closure device. Eight consecutive patients ranging between 22 and 83 years of age (mean 48 years) with PHT and/or LVDD or RV dysfunction who underwent fenestrated transcatheter ASD closure at UCLA were identified. None of the subjects experienced complications related to the procedure. Postprocedure clinical evaluation showed improvement in symptoms and exercise capacity. Available follow-up transthoracic echocardiography data (mean 4 months, range 0-20 months) demonstrated patent fenestrations in four of eight patients. None of the patients had thromboembolic or infectious complications and there were no device migrations, erosions or embolizations. Partial ASD occlusion in patients with diastolic dysfunction or RV dysfunction and/or PHT is safe and may be better tolerated than complete ASD closure in selected patients. © 2016 Wiley Periodicals, Inc.

  14. Transcatheter closure of patent ductus arteriosus in children weighing 10 kg or less: Initial experience at Sohag University Hospital.

    PubMed

    Ali, Safaa; El Sisi, Amel

    2016-04-01

    To assess the challenges, feasibility, and efficacy of device closure of patent ductus arteriosus (PDA) in small children weighing ⩽10 kg for different types of devices used in an initial experience at Sohag University hospital. Between March 2011 and September 2014, 91 patients with PDA underwent transcatheter closure in our institute, among whom 54 weighed ⩽10 kg. All of these patients underwent transcatheter closure of PDA using either a Cook Detachable Coil, PFM Nit-Occlud, or Amplatzer duct occluder. A retrospective review of the treatment results and adverse events was performed. Successful device placement was achieved in 53/54 small children (98.1%). The median minimum PDA diameter was 2.4 mm [interquartile range (IQR, 1.8-3.5 mm), median weight 8 kg (IQR, 7-10 kg), and median age 10 months (IQR, 8-17 months)]. Mild aortic obstruction occurred in one case (1.9%), as the device became displaced towards the aorta after release. The device embolized in one case (1.9%) and no retrieval attempt was made. Five cases (9.3%) had minor vascular complications. With the current availability of devices for PDA closure, transcatheter closure of PDA is considered safe and efficacious in small children weighing ⩽10 kg with good mid-term outcome. The procedure had a low rate of high-severity adverse events even with the initial experience of the catheterization laboratory.

  15. Transcatheter aortic valve-in-valve implantation of a CoreValve in a JenaValve prosthesis: a case report.

    PubMed

    Lotfi, Shahram; Becker, Michael; Moza, Ajay; Autschbach, Rüdiger; Marx, Nikolaus; Schröder, Jörg

    2017-09-10

    Transcatheter aortic valve implantation has become an accepted treatment modality for inoperable or high-risk surgical patients with symptomatic severe aortic stenosis. We report the case of a 70-year-old white man who was treated for severe symptomatic aortic regurgitation using transcatheter aortic valve implantation from the apical approach. Because of recurrent cardiac decompensation 4 weeks after implantation he underwent the implantation of a left ventricular assist device system. A year later echocardiography showed a severe transvalvular central insufficiency. Our heart team decided to choose a valve-in-valve approach while reducing the flow rate of left ventricular assist device to minimum and pacing with a frequency of 140 beats/minute. There was an excellent result and our patient is doing well with no relevant insufficiency of the aortic valve at 12-month follow-up. This is the first report about a successful treatment of a stenotic JenaValve using a CoreValve Evolut R; the use of a CoreValve Evolut R prosthesis may be an optimal option for valve-in-valve procedures.

  16. Concomitant Transapical Transcatheter Valve Implantations: Edwards Sapien Valve for Severe Mitral Regurgitation in a Patient with Failing Mitral Bioprostheses and JenaValve for the Treatment of Pure Aortic Regurgitation.

    PubMed

    Aydin, Unal; Gul, Mehmet; Aslan, Serkan; Akkaya, Emre; Yildirim, Aydin

    2015-04-28

    Transcatheter valve implantation is a novel interventional technique, which was developed as an  alternative therapy for surgical aortic valve replacement in inoperable patients with severe aortic stenosis. Despite limited experience in using transcatheter valve implantation for mitral and aortic regurgitation, transapical transcatheter aortic valve implantation and valve-in-valve implantation for degenerated mitral valve bioprosthesis can be performed in high-risk patients who are not candidates for conventional replacement surgery. In this case, we present the simultaneous transcatheter valve implantation via transapical approach for both degenerated bioprosthetic mitral valve with severe regurgitation and pure severe aortic regurgitation.

  17. Quantitative 3D investigation of Neuronal network in mouse spinal cord model

    NASA Astrophysics Data System (ADS)

    Bukreeva, I.; Campi, G.; Fratini, M.; Spanò, R.; Bucci, D.; Battaglia, G.; Giove, F.; Bravin, A.; Uccelli, A.; Venturi, C.; Mastrogiacomo, M.; Cedola, A.

    2017-01-01

    The investigation of the neuronal network in mouse spinal cord models represents the basis for the research on neurodegenerative diseases. In this framework, the quantitative analysis of the single elements in different districts is a crucial task. However, conventional 3D imaging techniques do not have enough spatial resolution and contrast to allow for a quantitative investigation of the neuronal network. Exploiting the high coherence and the high flux of synchrotron sources, X-ray Phase-Contrast multiscale-Tomography allows for the 3D investigation of the neuronal microanatomy without any aggressive sample preparation or sectioning. We investigated healthy-mouse neuronal architecture by imaging the 3D distribution of the neuronal-network with a spatial resolution of 640 nm. The high quality of the obtained images enables a quantitative study of the neuronal structure on a subject-by-subject basis. We developed and applied a spatial statistical analysis on the motor neurons to obtain quantitative information on their 3D arrangement in the healthy-mice spinal cord. Then, we compared the obtained results with a mouse model of multiple sclerosis. Our approach paves the way to the creation of a “database” for the characterization of the neuronal network main features for a comparative investigation of neurodegenerative diseases and therapies.

  18. Accurate quantitation of D+ fetomaternal hemorrhage by flow cytometry using a novel reagent to eliminate granulocytes from analysis.

    PubMed

    Kumpel, Belinda; Hazell, Matthew; Guest, Alan; Dixey, Jonathan; Mushens, Rosey; Bishop, Debbie; Wreford-Bush, Tim; Lee, Edmond

    2014-05-01

    Quantitation of fetomaternal hemorrhage (FMH) is performed to determine the dose of prophylactic anti-D (RhIG) required to prevent D immunization of D- women. Flow cytometry (FC) is the most accurate method. However, maternal white blood cells (WBCs) can give high background by binding anti-D nonspecifically, compromising accuracy. Maternal blood samples (69) were sent for FC quantitation of FMH after positive Kleihauer-Betke test (KBT) analysis and RhIG administration. Reagents used were BRAD-3-fluorescein isothiocyanate (FITC; anti-D), AEVZ5.3-FITC (anti-varicella zoster [anti-VZ], negative control), anti-fetal hemoglobin (HbF)-FITC, blended two-color reagents, BRAD-3-FITC/anti-CD45-phycoerythrin (PE; anti-D/L), and BRAD-3-FITC/anti-CD66b-PE (anti-D/G). PE-positive WBCs were eliminated from analysis by gating. Full blood counts were performed on maternal samples and female donors. Elevated numbers of neutrophils were present in 80% of patients. Red blood cell (RBC) indices varied widely in maternal blood. D+ FMH values obtained with anti-D/L, anti-D/G, and anti-HbF-FITC were very similar (r = 0.99, p < 0.001). Correlation between KBT and anti-HbF-FITC FMH results was low (r = 0.716). Inaccurate FMH quantitation using the current method (anti-D minus anti-VZ) occurred with 71% samples having less than 15 mL of D+ FMH (RBCs) and insufficient RhIG calculated for 9%. Using two-color reagents and anti-HbF-FITC, approximately 30% patients had elevated F cells, 26% had no fetal cells, 6% had D- FMH, 26% had 4 to 15 mL of D+ FMH, and 12% patients had more than 15 mL of D+ FMH (RBCs) requiring more than 300 μg of RhIG. Without accurate quantitation of D+ FMH by FC, some women would receive inappropriate or inadequate anti-D prophylaxis. The latter may be at risk of immunization leading to hemolytic disease of the newborn. © 2013 American Association of Blood Banks.

  19. Whole-body direct 4D parametric PET imaging employing nested generalized Patlak expectation-maximization reconstruction

    PubMed Central

    Karakatsanis, Nicolas A.; Casey, Michael E.; Lodge, Martin A.; Rahmim, Arman; Zaidi, Habib

    2016-01-01

    Whole-body (WB) dynamic PET has recently demonstrated its potential in translating the quantitative benefits of parametric imaging to the clinic. Post-reconstruction standard Patlak (sPatlak) WB graphical analysis utilizes multi-bed multi-pass PET acquisition to produce quantitative WB images of the tracer influx rate Ki as a complimentary metric to the semi-quantitative standardized uptake value (SUV). The resulting Ki images may suffer from high noise due to the need for short acquisition frames. Meanwhile, a generalized Patlak (gPatlak) WB post-reconstruction method had been suggested to limit Ki bias of sPatlak analysis at regions with non-negligible 18F-FDG uptake reversibility; however, gPatlak analysis is non-linear and thus can further amplify noise. In the present study, we implemented, within the open-source Software for Tomographic Image Reconstruction (STIR) platform, a clinically adoptable 4D WB reconstruction framework enabling efficient estimation of sPatlak and gPatlak images directly from dynamic multi-bed PET raw data with substantial noise reduction. Furthermore, we employed the optimization transfer methodology to accelerate 4D expectation-maximization (EM) convergence by nesting the fast image-based estimation of Patlak parameters within each iteration cycle of the slower projection-based estimation of dynamic PET images. The novel gPatlak 4D method was initialized from an optimized set of sPatlak ML-EM iterations to facilitate EM convergence. Initially, realistic simulations were conducted utilizing published 18F-FDG kinetic parameters coupled with the XCAT phantom. Quantitative analyses illustrated enhanced Ki target-to-background ratio (TBR) and especially contrast-to-noise ratio (CNR) performance for the 4D vs. the indirect methods and static SUV. Furthermore, considerable convergence acceleration was observed for the nested algorithms involving 10–20 sub-iterations. Moreover, systematic reduction in Ki % bias and improved TBR were

  20. Whole-body direct 4D parametric PET imaging employing nested generalized Patlak expectation-maximization reconstruction

    NASA Astrophysics Data System (ADS)

    Karakatsanis, Nicolas A.; Casey, Michael E.; Lodge, Martin A.; Rahmim, Arman; Zaidi, Habib

    2016-08-01

    Whole-body (WB) dynamic PET has recently demonstrated its potential in translating the quantitative benefits of parametric imaging to the clinic. Post-reconstruction standard Patlak (sPatlak) WB graphical analysis utilizes multi-bed multi-pass PET acquisition to produce quantitative WB images of the tracer influx rate K i as a complimentary metric to the semi-quantitative standardized uptake value (SUV). The resulting K i images may suffer from high noise due to the need for short acquisition frames. Meanwhile, a generalized Patlak (gPatlak) WB post-reconstruction method had been suggested to limit K i bias of sPatlak analysis at regions with non-negligible 18F-FDG uptake reversibility; however, gPatlak analysis is non-linear and thus can further amplify noise. In the present study, we implemented, within the open-source software for tomographic image reconstruction platform, a clinically adoptable 4D WB reconstruction framework enabling efficient estimation of sPatlak and gPatlak images directly from dynamic multi-bed PET raw data with substantial noise reduction. Furthermore, we employed the optimization transfer methodology to accelerate 4D expectation-maximization (EM) convergence by nesting the fast image-based estimation of Patlak parameters within each iteration cycle of the slower projection-based estimation of dynamic PET images. The novel gPatlak 4D method was initialized from an optimized set of sPatlak ML-EM iterations to facilitate EM convergence. Initially, realistic simulations were conducted utilizing published 18F-FDG kinetic parameters coupled with the XCAT phantom. Quantitative analyses illustrated enhanced K i target-to-background ratio (TBR) and especially contrast-to-noise ratio (CNR) performance for the 4D versus the indirect methods and static SUV. Furthermore, considerable convergence acceleration was observed for the nested algorithms involving 10-20 sub-iterations. Moreover, systematic reduction in K i % bias and improved TBR were

  1. Registry of transcatheter aortic-valve implantation in high-risk patients.

    PubMed

    Gilard, Martine; Eltchaninoff, Hélène; Iung, Bernard; Donzeau-Gouge, Patrick; Chevreul, Karine; Fajadet, Jean; Leprince, Pascal; Leguerrier, Alain; Lievre, Michel; Prat, Alain; Teiger, Emmanuel; Lefevre, Thierry; Himbert, Dominique; Tchetche, Didier; Carrié, Didier; Albat, Bernard; Cribier, Alain; Rioufol, Gilles; Sudre, Arnaud; Blanchard, Didier; Collet, Frederic; Dos Santos, Pierre; Meneveau, Nicolas; Tirouvanziam, Ashok; Caussin, Christophe; Guyon, Philippe; Boschat, Jacques; Le Breton, Herve; Collart, Frederic; Houel, Remi; Delpine, Stephane; Souteyrand, Geraud; Favereau, Xavier; Ohlmann, Patrick; Doisy, Vincent; Grollier, Gilles; Gommeaux, Antoine; Claudel, Jean-Philippe; Bourlon, Francois; Bertrand, Bernard; Van Belle, Eric; Laskar, Marc

    2012-05-03

    Transcatheter aortic-valve implantation (TAVI) is an emerging intervention for the treatment of high-risk patients with severe aortic stenosis and coexisting illnesses. We report the results of a prospective multicenter study of the French national transcatheter aortic-valve implantation registry, FRANCE 2. All TAVIs performed in France, as listed in the FRANCE 2 registry, were prospectively included in the study. The primary end point was death from any cause. A total of 3195 patients were enrolled between January 2010 and October 2011 at 34 centers. The mean (±SD) age was 82.7±7.2 years; 49% of the patients were women. All patients were highly symptomatic and were at high surgical risk for aortic-valve replacement. Edwards SAPIEN and Medtronic CoreValve devices were implanted in 66.9% and 33.1% of patients, respectively. Approaches were either transarterial (transfemoral, 74.6%; subclavian, 5.8%; and other, 1.8%) or transapical (17.8%). The procedural success rate was 96.9%. Rates of death at 30 days and 1 year were 9.7% and 24.0%, respectively. At 1 year, the incidence of stroke was 4.1%, and the incidence of periprosthetic aortic regurgitation was 64.5%. In a multivariate model, a higher logistic risk score on the European System for Cardiac Operative Risk Evaluation (EuroSCORE), New York Heart Association functional class III or IV symptoms, the use of a transapical TAVI approach, and a higher amount of periprosthetic regurgitation were significantly associated with reduced survival. This prospective registry study reflected real-life TAVI experience in high-risk elderly patients with aortic stenosis, in whom TAVI appeared to be a reasonable option. (Funded by Edwards Lifesciences and Medtronic.).

  2. A New Soluble Gelatin Sponge for Transcatheter Hepatic Arterial Embolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takasaka, Isao; Kawai, Nobuyuki; Sato, Morio, E-mail: morisato@mail.wakayama-med.ac.jp

    2010-12-15

    To prepare a soluble gelatin sponge (GS) and to explore the GS particles (GSPs) that inhibit development of collateral pathways when transcatheter hepatic arterial embolization is performed. The approval of the Institutional Committee on Research Animal Care of our institution was obtained. By means of 50 and 100 kDa of regenerative medicine-gelatin (RM-G), RM-G sponges were prepared by freeze-drying and heating to temperatures of 110-150{sup o}C for cross-linkage. The soluble times of RM-GSPs were measured in vitro. Eight swine for transcatheter hepatic arterial embolization were assigned into two groups: six received 135{sup o}C/50RM-GSPs, 125{sup o}C/100RM-GSPs, and 138{sup o}C/50RM-GSPs, with solublemore » time of 48 h or more in vitro; two swine received Gelpart GSPs (G-GSPs) with insoluble time of 14 days as a control. Transarterial chemoembolization was performed on two branches of the hepatic artery per swine. RM-GSPs heated at temperatures of 110-138{sup o}C were soluble. Mean soluble times of the RM-GSPs increased with higher temperature. Hepatic branches embolized with G-GSP remained occluded after 6 days, and development of collateral pathways was observed after 3 days. Hepatic branches embolized with 135{sup o}C/50RM-GSP and 125{sup o}C/100RM-GSP remained occluded for 4 h, and recanalization was observed after 1 day. Hepatic branches embolized with 138{sup o}C/50RM-GS remained occluded for 1 day, and recanalization was observed after 2 days with no development of collateral pathways. In RM-GSs with various soluble times that were prepared by modulating the heating temperature, 138{sup o}C/50RM-GSP was the soluble GSP with the longest occlusion time without inducing development of collateral pathways.« less

  3. Left main coronary artery obstruction by dislodged native-valve calculus after transcatheter aortic valve replacement.

    PubMed

    Durmaz, Tahir; Ayhan, Huseyin; Keles, Telat; Aslan, Abdullah Nabi; Erdogan, Kemal Esref; Sari, Cenk; Bilen, Emine; Akcay, Murat; Bozkurt, Engin

    2014-08-01

    Transcatheter aortic valve replacement can be an effective, reliable treatment for severe aortic stenosis in surgically high-risk or ineligible patients. However, various sequelae like coronary artery obstruction can occur, not only in the long term, but also immediately after the procedure. We present the case of a 78-year-old woman whose left main coronary artery became obstructed with calculus 2 hours after the transfemoral implantation of an Edwards Sapien XT aortic valve. Despite percutaneous coronary intervention in that artery, the patient died. This case reminds us that early recognition of acute coronary obstruction and prompt intervention are crucial in patients with aortic stenosis who have undergone transcatheter aortic valve replacement.

  4. Left Main Coronary Artery Obstruction by Dislodged Native-Valve Calculus after Transcatheter Aortic Valve Replacement

    PubMed Central

    Durmaz, Tahir; Keles, Telat; Aslan, Abdullah Nabi; Erdogan, Kemal Esref; Sari, Cenk; Bilen, Emine; Akcay, Murat; Bozkurt, Engin

    2014-01-01

    Transcatheter aortic valve replacement can be an effective, reliable treatment for severe aortic stenosis in surgically high-risk or ineligible patients. However, various sequelae like coronary artery obstruction can occur, not only in the long term, but also immediately after the procedure. We present the case of a 78-year-old woman whose left main coronary artery became obstructed with calculus 2 hours after the transfemoral implantation of an Edwards Sapien XT aortic valve. Despite percutaneous coronary intervention in that artery, the patient died. This case reminds us that early recognition of acute coronary obstruction and prompt intervention are crucial in patients with aortic stenosis who have undergone transcatheter aortic valve replacement. PMID:25120396

  5. Modeling 4D Pathological Changes by Leveraging Normative Models

    PubMed Central

    Wang, Bo; Prastawa, Marcel; Irimia, Andrei; Saha, Avishek; Liu, Wei; Goh, S.Y. Matthew; Vespa, Paul M.; Van Horn, John D.; Gerig, Guido

    2016-01-01

    quantitative analysis of 4D imaging representing spatio-temporal changes of pathologies. PMID:27818606

  6. Transcatheter aortic valve insertion (TAVI): a review

    PubMed Central

    Morgan-Hughes, G; Roobottom, C

    2014-01-01

    The introduction of transcatheter aortic valve insertion (TAVI) has transformed the care provided for patients with severe aortic stenosis. The uptake of this procedure is increasing rapidly, and clinicians from all disciplines are likely to increasingly encounter patients being assessed for or having undergone this intervention. Successful TAVI heavily relies on careful and comprehensive imaging assessment, before, during and after the procedure, using a range of modalities. This review outlines the background and development of TAVI, describes the nature of the procedure and considers the contribution of imaging techniques, both to successful intervention and to potential complications. PMID:24258463

  7. 3-D Quantitative Dynamic Contrast Ultrasound for Prostate Cancer Localization.

    PubMed

    Schalk, Stefan G; Huang, Jing; Li, Jia; Demi, Libertario; Wijkstra, Hessel; Huang, Pintong; Mischi, Massimo

    2018-04-01

    To investigate quantitative 3-D dynamic contrast-enhanced ultrasound (DCE-US) and, in particular 3-D contrast-ultrasound dispersion imaging (CUDI), for prostate cancer detection and localization, 43 patients referred for 10-12-core systematic biopsy underwent 3-D DCE-US. For each 3-D DCE-US recording, parametric maps of CUDI-based and perfusion-based parameters were computed. The parametric maps were divided in regions, each corresponding to a biopsy core. The obtained parameters were validated per biopsy location and after combining two or more adjacent regions. For CUDI by correlation (r) and for the wash-in time (WIT), a significant difference in parameter values between benign and malignant biopsy cores was found (p < 0.001). In a per-prostate analysis, sensitivity and specificity were 94% and 50% for r, and 53% and 81% for WIT. Based on these results, it can be concluded that quantitative 3-D DCE-US could aid in localizing prostate cancer. Therefore, we recommend follow-up studies to investigate its value for targeting biopsies. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  8. Multimodality imaging to plan and guide transcatheter tricuspid valve interventions.

    PubMed

    Prihadi, Edgard A; Delgado, Victoria; Bax, Jeroen J

    2017-10-01

    Tricuspid regurgitation (TR) is a highly prevalent valvular heart disease. The natural history of untreated significant TR portends an unfavorable outcome, but only a minority of patients is currently referred for surgical treatment. Organic TR (caused by primary abnormality of the leaflets) is relatively infrequent whereas secondary or functional TR (caused by dilatation of the tricuspid annulus, right ventricle [RV] and right atrium) is the predominant mechanism. The success of transcatheter therapies for left valvular heart disease over the last decade, has fueled similar development of novel transcatheter devices for the treatment of TR. Currently being tested in several clinical trials, each of these devices requires specific needs to define the procedural suitability. In addition, an accurate evaluation of the complex tricuspid anatomy, RV geometry and their relationship with the surrounding structures is mandatory. Therefore, accurate pre-procedural assessment using multimodality imaging techniques will undoubtedly play a pivotal role in achieving procedural success and safety. This review article provides a comprehensive overview on the etiology and different mechanisms of TR, and highlights the role of multimodality imaging techniques in the assessment of TR severity, RV dysfunction and fulfilment of device-specific selection criteria.

  9. How to Perform Transcaval Access and Closure for Transcatheter Aortic Valve Implantation

    PubMed Central

    Lederman, Robert J.; Babaliaros, Vasilis C.; Greenbaum, Adam B.

    2016-01-01

    Transcaval, or caval-aortic, access is a promising approach for fully percutaneous trans-catheter aortic valve implantation in patients without good conventional access options. This tutorial review provides step-by-step guidance to planning and executing the procedure, along with approaches to remedy complications. PMID:26356244

  10. Prevalence and Outcomes of Mitral Stenosis in Patients Undergoing Transcatheter Aortic Valve Replacement: Findings From the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapies Registry.

    PubMed

    Joseph, Lee; Bashir, Mohammad; Xiang, Qun; Yerokun, Babatunde A; Matsouaka, Roland Albert; Vemulapalli, Sreekanth; Kapadia, Samir; Cigarroa, Joaquin E; Zahr, Firas

    2018-04-09

    This study sought to examine the prevalence of mitral stenosis (MS) and its impact on in-hospital and 1-year clinical outcomes among patients undergoing transcatheter aortic valve replacement (TAVR). Patients with coexisting severe aortic stenosis and MS are increasingly being considered for TAVR. The study cohort included 44,755 patients (age ≥18 years) who underwent TAVR during November 1, 2011, to September 30, 2015, and were registered in Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapies (TVT) Registry. One-year outcomes were assessed by linking TVT registry data of this cohort to patient-specific Centers for Medicare & Medicaid Services administrative claims data (n = 31,453). The primary outcome was the composite of death, stroke, heart failure-related hospitalization, and mitral valve intervention at 1 year. MS was present in 11.6% of cohort (mean age, 82 years; 52% males), being severe in 2.7%. Severe MS was associated with higher in-hospital mortality rates (5.6% vs. 3.9% for nonsevere MS and 4.1% for no MS; p = 0.02). In contrast to those without MS, severe MS group had significantly higher risk for the primary outcome, mortality (1 year), and heart failure-related hospitalization (1 year) (adjusted hazard ratio: 1.2 [95% confidence interval (CI): 1.1 to 1.4], 1.2 [95% CI: 1.0 to 1.4], and 1.3 [95% CI: 1.1 to 1.5], respectively; p < 0.05 for all). Approximately one-tenth of patients undergoing TAVR have concomitant MS. Severe MS is an independent predictor of 1-year adverse clinical outcomes following TAVR. The higher risk for long-term adverse events must be considered when evaluating patients with combined aortic stenosis and MS for TAVR. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  11. Advanced 3-D analysis, client-server systems, and cloud computing-Integration of cardiovascular imaging data into clinical workflows of transcatheter aortic valve replacement.

    PubMed

    Schoenhagen, Paul; Zimmermann, Mathis; Falkner, Juergen

    2013-06-01

    Degenerative aortic stenosis is highly prevalent in the aging populations of industrialized countries and is associated with poor prognosis. Surgical valve replacement has been the only established treatment with documented improvement of long-term outcome. However, many of the older patients with aortic stenosis (AS) are high-risk or ineligible for surgery. For these patients, transcatheter aortic valve replacement (TAVR) has emerged as a treatment alternative. The TAVR procedure is characterized by a lack of visualization of the operative field. Therefore, pre- and intra-procedural imaging is critical for patient selection, pre-procedural planning, and intra-operative decision-making. Incremental to conventional angiography and 2-D echocardiography, multidetector computed tomography (CT) has assumed an important role before TAVR. The analysis of 3-D CT data requires extensive post-processing during direct interaction with the dataset, using advance analysis software. Organization and storage of the data according to complex clinical workflows and sharing of image information have become a critical part of these novel treatment approaches. Optimally, the data are integrated into a comprehensive image data file accessible to multiple groups of practitioners across the hospital. This creates new challenges for data management requiring a complex IT infrastructure, spanning across multiple locations, but is increasingly achieved with client-server solutions and private cloud technology. This article describes the challenges and opportunities created by the increased amount of patient-specific imaging data in the context of TAVR.

  12. Which way in? The Necessity of Multiple Approaches to Transcatheter Valve Therapy

    PubMed Central

    Bleiziffer, S.; Krane, M.; Deutsch, M.A.; Elhmidi, Y.; Piazza, N.; Voss, B.; Lange, R.

    2013-01-01

    TAVI (transcatheter aortic valve implantation) is a less invasive treatment of the stenotic aortic valve while avoiding midline sternotomy and cardiopulmonary bypass. A crimped biological valve on a self-expanding or balloon-expandable stent is inserted antegradely or retrogradely under fluoroscopy, and deployed on the beating heart. Among the worldwide TAVI programs, many different concepts have been established for the choice of the access site. Whether retrograde or antegrade TAVI should be considered the superior approach is matter of an ongoing debate. The published literature demonstrates safety of all techniques if performed within a dedicated multidisciplinary team. Since there is no data providing evidence if one approach is superior to another, we conclude that an individualized patient-centered decision making process is most beneficial, taking advantage of the complementarity of the different access options. The aim of this article is to give an overview of the current practice of access techniques for transcatheter based valve treatment and to outline the respective special characteristics. PMID:24313647

  13. The effects of contrast media volume on acute kidney injury after transcatheter aortic valve replacement: a systematic review and meta-analysis.

    PubMed

    Thongprayoon, Charat; Cheungpasitporn, Wisit; Podboy, Alexander J; Gillaspie, Erin A; Greason, Kevin L; Kashani, Kianoush B

    2016-11-01

    The goal of this systematic review was to assess the effects of contrast media volume on transcatheter aortic valve replacement-related acute kidney injury. A literature search was performed using Medline, EMbase, the Cochrane Database of Systematic Reviews, and clinicaltrials.gov from the inception of these databases through December 2015. Studies that reported relative risk, odds ratio, or hazard ratio comparing the risks of acute kidney injury following transcatheter aortic valve replacement in patients who received high contrast media volume were included. Pooled risk ratio (RR) and 95% confidence intervals (95% CI) were calculated using a random-effect, generic inverse variance method. Four cohort studies composed of 891 patients were included in the analyses to assess the risk of acute kidney injury after transcatheter aortic valve replacement in patients who received high contrast media volume. The pooled RR of acute kidney injury after transcatheter aortic valve replacement in patients who received a large volume of contrast media was 1.41 (95% CI, 0.87 to 2.28) compared with low contrast media volume. The meta-analysis was limited to studies using standard acute kidney injury definitions, and the pooled RR of acute kidney injury in patients who received high contrast media volume is 1.12 (95% CI, 0.78 to 1.62). Our meta-analysis shows no significant association between contrast media volume and risk of acute kidney injury after transcatheter aortic valve replacement. © 2016 Chinese Cochrane Center, West China Hospital of Sichuan University and John Wiley & Sons Australia, Ltd.

  14. Transcatheter closure of calcified patent ductus arteriosus in older adult patients: Immediate and 12-month follow-up results.

    PubMed

    Gu, Xinghua; Zhang, Qiuwang; Sun, Hourong; Fei, Jianchun; Zhang, Xiquan; Kutryk, Michael J

    2017-05-01

    To present our experience in transcatheter closure of calcified patent ductus arteriosus (PDA) in older adult patients, which has rarely been reported. From 2009 to 2014, a total of 16 patients (median age 58 years) with calcified PDA underwent transcatheter closure in our center. All patients were symptomatic with major symptoms being exertional dyspnea (in 12), palpitations (in 8), and fatigue (in 5). A continuous murmur was heard in all patients. The median ductus diameter was 4 mm (range 3-7 mm). The median Qp/Qs was 1.6 (range 1.4-2.9). Transcatheter closure was performed for all patients. The size of the occluder selected was 2-3 mm greater than the narrowest portion of PDA. We experienced difficulties in advancing the multipurpose catheter through the calcified duct in about one third of patients (5/16). Considering that calcified tissue has a greater tendency to rupture, hence, to close PDA in these patients, they adopted the retrograde wire-assisted technique and modified the procedure to reduce the shear stress of sheath and avoid any sheath kinking. For the remaining 11 patients, the advancement of the multipurpose catheter through the calcified duct was smooth and the conventional antegrade approach was applied. Clinical examination, standard 12-lead electrocardiography, chest x-ray, and transthoracic echocardiography were performed before hospital discharge, at 1-, 3-, 6-, and 12-months follow-ups. All PDAs were successfully closed. There were no deaths. Three patients had a trivial residual shunt, with one also having intravascular hemolysis. Following pharmacological treatment, hemolysis signs vanished at 7 days postprocedure. The trivial residual shunt disappeared in all three patients at 3-month follow-up. No new-onset residual shunt, device embolization, device dislocation, infective endocarditis, or embolism was observed at all follow-up time points. Successful closure of calcified PDA with few complications in older adult patients was achieved

  15. The 4d8-(4d74f + 4d76p + 4p54d9) transitions in the spectrum of five times ionized indium (In VI)

    NASA Astrophysics Data System (ADS)

    Ryabtsev, A. N.; Tauheed, A.; Swapnil; Kildiyarova, R. R.; Kononov, E. Ya

    2018-06-01

    The spectrum of five times ionized indium excited in a vacuum spark has been studied in the wavelength region 180-250 Å using a 3 m grazing incidence spectrograph. Transitions from highly excited interacting configurations 4d74f + 4d76p + 4p54d9 to the ground state 4d8 configuration were studied. 165 spectral lines were identified and 81 levels of the excited configurations were found.

  16. Transcatheter Aortic Valve Implantation: Experience with the CoreValve Device.

    PubMed

    Asgar, Anita W; Bonan, Raoul

    2012-01-01

    The field of transcatheter aortic valve implantation has been rapidly evolving. The Medtronic CoreValve first emerged on the landscape in 2004 with initial first human studies, and it is currently being studied in the Pivotal US trial. This article details the current experience with the self-expanding aortic valve with a focus on clinical results and ongoing challenges. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. SU-E-J-154: Image Quality Assessment of Contrast-Enhanced 4D-CT for Pancreatic Adenocarcinoma in Radiotherapy Simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, W; Xue, M; Patel, K

    2015-06-15

    Purpose: This study presents quantitative and qualitative assessment of the image qualities in contrast-enhanced (CE) 3D-CT, 4D-CT and CE 4D-CT to identify feasibility for replacing the clinical standard simulation with a single CE 4D-CT for pancreatic adenocarcinoma (PDA) in radiotherapy simulation. Methods: Ten PDA patients were enrolled and underwent three CT scans: a clinical standard pair of CE 3D-CT immediately followed by a 4D-CT, and a CE 4D-CT one week later. Physicians qualitatively evaluated the general image quality and regional vessel definitions and gave a score from 1 to 5. Next, physicians delineated the contours of the tumor (T) andmore » the normal pancreatic parenchyma (P) on the three CTs (CE 3D-CT, 50% phase for 4D-CT and CE 4D-CT), then high density areas were automatically removed by thresholding at 500 HU and morphological operations. The pancreatic tumor contrast-to-noise ratio (CNR), signal-tonoise ratio (SNR) and conspicuity (C, absolute difference of mean enhancement levels in P and T) were computed to quantitatively assess image quality. The Wilcoxon rank sum test was used to compare these quantities. Results: In qualitative evaluations, CE 3D-CT and CE 4D-CT scored equivalently (4.4±0.4 and 4.3±0.4) and both were significantly better than 4D-CT (3.1±0.6). In quantitative evaluations, the C values were higher in CE 4D-CT (28±19 HU, p=0.19 and 0.17) than the clinical standard pair of CE 3D-CT and 4D-CT (17±12 and 16±17 HU, p=0.65). In CE 3D-CT and CE 4D-CT, mean CNR (1.8±1.4 and 1.8±1.7, p=0.94) and mean SNR (5.8±2.6 and 5.5±3.2, p=0.71) both were higher than 4D-CT (CNR: 1.1±1.3, p<0.3; SNR: 3.3±2.1, p<0.1). The absolute enhancement levels for T and P were higher in CE 4D-CT (87, 82 HU) than in CE 3D-CT (60, 56) and 4DCT (53, 70). Conclusions: The individually optimized CE 4D-CT is feasible and achieved comparable image qualities to the clinical standard simulation. This study was supported in part by Philips Healthcare.« less

  18. Optimal prosthesis sizing in transcatheter aortic valve implantation by exclusive use of three-dimensional transoesophageal echocardiography.

    PubMed

    Kretzschmar, Daniel; Lauten, Alexander; Goebel, Bjoern; Doenst, Torsten; Poerner, Tudor C; Ferrari, Markus; Figulla, Hans R; Hamadanchi, Ali

    2016-03-01

    The assessment of aortic annular size is critical, and inappropriate sizing is thought to be a main reason of paravalvular aortic regurgitation. Multidetector computed tomograph is associated with the risk of contrast nephropathy. For optimal evaluation of the complex structure of the aortic annulus, three-dimensional (3D)-methods should be used. We therefore sought to determine the value of 3D-transoesophageal echocardiography (3D-TEE) for appropriate sizing. Hundred and one patients (mean age 81·4 years) with symptomatic aortic valve stenosis (AS) and high surgical risk profile (mean log. EuroScore 28·8%) being scheduled for transcatheter aortic valve implantation (TAVI) were included. 2D- and 3D-TEE were performed before the procedure to evaluate the aortic annulus diameter. Maximum, minimum and mean (max diameter + min diameter/2) annulus diameters were 24·7, 23·1 and 23. 9 mm in 3D-TEE and compared to 22·6 mm in 2D-TEE (P<0·001; 0·07; <0·001). The interobserver variability for 3D-TEE was low with a mean difference of 0·18 mm compared to 2D-TEE with 0·59 mm. The application of 3D-TEE caused a change of prosthesis size selection in 40% of patients compared to 2D-TEE. In this study, we implanted three different types of catheter-mounted valves (Edwards-SAPIEN(™) XT valve, CoreValve(™) and JenaValve(™) ). Final angiography confirmed valve competence (mild insufficiency) in 91%, and there was no aortic regurgitation greater than moderate in the follow-up echocardiographic evaluation. Assessment of aortic annulus dimensions for TAVI size selection can safely be performed with 3D-TEE only. Based on our results with significantly higher annulus diameter compared to 2D-TEE, we recommend 3D-TEE to reduce prosthesis undersizing. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  19. Redo aortic valve surgery versus transcatheter valve-in-valve implantation for failing surgical bioprosthetic valves: consecutive patients in a single-center setting

    PubMed Central

    Wottke, Michael; Deutsch, Marcus-André; Krane, Markus; Piazza, Nicolo; Lange, Ruediger; Bleiziffer, Sabine

    2015-01-01

    Background Due to a considerable rise in bioprosthetic as opposed to mechanical valve implantations, an increase of patients presenting with failing bioprosthetic surgical valves in need of a reoperation is to be expected. Redo surgery may pose a high-risk procedure. Transcatheter aortic valve-in-valve implantation is an innovative, less-invasive treatment alternative for these patients. However, a comprehensive evaluation of the outcome of consecutive patients after a valve-in-valve TAVI [transcatheter aortic valve-in-surgical aortic valve (TAV-in-SAV)] as compared to a standard reoperation [surgical aortic valve redo-operation (SAV-in-SAV)] has not yet been performed. The goal of this study was to compare postoperative outcomes after TAV-in-SAV and SAV-in-SAV in a single center setting. Methods All SAV-in-SAV and TAV-in-SAV patients from January 2001 to October 2014 were retrospectively reviewed. Patients with previous mechanical or transcatheter valves, active endocarditis and concomitant cardiac procedures were excluded. Patient characteristics, preoperative data, post-procedural complications, and 30-day mortality were collected from a designated database. Mean values ± SD were calculated for all continuous variables. Counts and percentages were calculated for categorical variables. The Chi-square and Fisher exact tests were used to compare categorical variables. Continuous variables were compared using the t-test for independent samples. A 2-sided P value <0.05 was considered statistically significant. Results A total of 102 patients fulfilled the inclusion criteria, 50 patients (49%) underwent a transcatheter valve-in-valve procedure, while 52 patients (51%) underwent redo-surgery. Patients in the TAV-in-SAV group were significantly older, had a higher mean logistic EuroSCORE and exhibited a lower mean left ventricular ejection fraction than patients in the SAV-in-SAV group (78.1±6.7 vs. 66.2±13.1, P<0.001; 27.4±18.7 vs. 14.4±10, P<0.001; and 49.8±13

  20. Patient-specific dosimetry based on quantitative SPECT imaging and 3D-DFT convolution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akabani, G.; Hawkins, W.G.; Eckblade, M.B.

    1999-01-01

    The objective of this study was to validate the use of a 3-D discrete Fourier Transform (3D-DFT) convolution method to carry out the dosimetry for I-131 for soft tissues in radioimmunotherapy procedures. To validate this convolution method, mathematical and physical phantoms were used as a basis of comparison with Monte Carlo transport (MCT) calculations which were carried out using the EGS4 system code. The mathematical phantom consisted of a sphere containing uniform and nonuniform activity distributions. The physical phantom consisted of a cylinder containing uniform and nonuniform activity distributions. Quantitative SPECT reconstruction was carried out using the Circular Harmonic Transformmore » (CHT) algorithm.« less

  1. Clinical Impact of Diabetes Mellitus on Outcomes After Transcatheter Aortic Valve Replacement: Insights From the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry.

    PubMed

    Abramowitz, Yigal; Vemulapalli, Sreekanth; Chakravarty, Tarun; Li, Zhuokai; Kapadia, Samir; Holmes, David; Matsouaka, Roland A; Wang, Alice; Cheng, Wen; Forrester, James S; Smalling, Richard; Thourani, Vinod; Mack, Michael; Leon, Martin; Makkar, Raj R

    2017-11-01

    Diabetes mellitus (DM) adversely affects morbidity and mortality for cardiovascular diseases and procedures. Data evaluating the outcomes of transcatheter aortic valve replacement (TAVR) in diabetic patients are limited by small sample size and contradictory results. We aimed to establish the magnitude of risk and the incremental influence of insulin dependency by examining short- and long-term adverse outcomes according to DM status and therapy in the world's largest TAVR registry. We analyzed data from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. In-hospital mortality, 30-day mortality, and 1-year mortality after TAVR in patients with and without DM were evaluated using multivariate modeling. Among 47 643 patients treated with TAVR from November 2011 through September 2015 at 394 US hospitals, there were 17 849 (37.5%) patients with DM. Overall, 6600 of the diabetic patients were insulin treated (IT). Thirty-day mortality was 5.0% in patients with DM (6.1% in IT DM and 4.4% in non-IT DM; P <0.001) versus 5.9% in patients without DM ( P <0.001). Overall, 1-year mortality was 21.8% in patients with DM (24.8% in IT DM and 20.1% in non-IT DM; P <0.001) versus 21.2% in patients without DM ( P =0.274). In a multivariable model, DM was associated with increased 1-year mortality (hazard ratio, 1.30; 95% confidence interval, 1.13-1.49; P <0.001). Subgroup multivariable analysis showed stronger mortality association in IT diabetics (hazard ratio, 1.57; 95% confidence interval, 1.28-1.91; P <0.001) than in non-IT diabetics (hazard ratio, 1.17; 95% confidence interval, 1.00-1.38; P =0.052). Our data establish the magnitude of short- and long-term risk conferred by DM and the incremental risk conferred by insulin dependency in the performance of TAVR. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01737528. © 2017 American Heart Association, Inc.

  2. Renoduodenal Fistula After Transcatheter Embolization of Renal Angiomyolipoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheth, Rahul A.; Feldman, Adam S.; Walker, T. Gregory, E-mail: tgwalker@partners.org

    Transcatheter embolization of renal angiomyolipomas is a routinely performed, nephron-sparing procedure with a favorable safety profile. Complications from this procedure are typically minor in severity, with postembolization syndrome the most common minor complication. Abscess formation is a recognized but uncommon major complication of this procedure and is presumably due to superinfection of the infarcted tissue after arterial embolization. In this case report, we describe the formation of a renoduodenal fistula after embolization of an angiomyolipoma, complicated by intracranial abscess formation and requiring multiple percutaneous drainage procedures and eventual partial nephrectomy.

  3. Transcatheter closure of patent ductus arteriosus in children weighing 10 kg or less: Initial experience at Sohag University Hospital

    PubMed Central

    Ali, Safaa; El Sisi, Amel

    2015-01-01

    Aim To assess the challenges, feasibility, and efficacy of device closure of patent ductus arteriosus (PDA) in small children weighing ⩽10 kg for different types of devices used in an initial experience at Sohag University hospital. Methods Between March 2011 and September 2014, 91 patients with PDA underwent transcatheter closure in our institute, among whom 54 weighed ⩽10 kg. All of these patients underwent transcatheter closure of PDA using either a Cook Detachable Coil, PFM Nit-Occlud, or Amplatzer duct occluder. A retrospective review of the treatment results and adverse events was performed. Results Successful device placement was achieved in 53/54 small children (98.1%). The median minimum PDA diameter was 2.4 mm [interquartile range (IQR, 1.8–3.5 mm), median weight 8 kg (IQR, 7–10 kg), and median age 10 months (IQR, 8–17 months)]. Mild aortic obstruction occurred in one case (1.9%), as the device became displaced towards the aorta after release. The device embolized in one case (1.9%) and no retrieval attempt was made. Five cases (9.3%) had minor vascular complications. Conclusion With the current availability of devices for PDA closure, transcatheter closure of PDA is considered safe and efficacious in small children weighing ⩽10 kg with good mid-term outcome. The procedure had a low rate of high-severity adverse events even with the initial experience of the catheterization laboratory. PMID:27053899

  4. Transcatheter arterial embolization for acute nonvariceal upper gastrointestinal bleeding: Indications, techniques and outcomes.

    PubMed

    Loffroy, R; Favelier, S; Pottecher, P; Estivalet, L; Genson, P Y; Gehin, S; Cercueil, J P; Krausé, D

    2015-01-01

    Over the past three decades, transcatheter arterial embolization has become the first-line therapy for the management of acute nonvariceal upper gastrointestinal bleeding that is refractory to endoscopic hemostasis. Advances in catheter-based techniques and newer embolic agents, as well as recognition of the effectiveness of minimally invasive treatment options, have expanded the role of interventional radiology in the treatment of bleeding for a variety of indications. Transcatheter arterial embolization is a fast, safe, and effective minimally invasive alternative to surgery, when endoscopic treatment fails to control acute bleeding from the upper gastrointestinal tract. This article describes the role of arterial embolization in the management of acute nonvariceal upper gastrointestinal bleeding and summarizes the literature evidence on the outcomes of endovascular therapy in such a setting. Copyright © 2015 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  5. Recent development of transcatheter closure of atrial septal defect and patent foramen ovale with occluders.

    PubMed

    Tang, Baiyu; Su, Feng; Sun, Xiangke; Wu, Qin; Xing, Quansheng; Li, Suming

    2018-01-01

    Atrial septal defect (ASD) and patent foramen ovale (PFO) are common clinical congenital heart defects. As an effective method for the treatment of ASD and PFO, transcatheter closure with occluders presents many advantages, including safety, ease of operation, minimal invasiveness, and reduced complications. This contribution reviews the various types of occluders currently used in clinical applications and under development, including non degradable occluders, partially degradable occluders, and totally degradable occluders. A number of case studies are described in detail. Comparison is made on the treatment outcomes using different occulders. Future development of transcatheter closure is discussed, in particular the use of totally degradable occluders. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 433-443, 2018. © 2016 Wiley Periodicals, Inc.

  6. 2D/ 3D Quantitative Ultrasound of the Breast

    NASA Astrophysics Data System (ADS)

    Nasief, Haidy Gerges

    Breast cancer is the second leading cause of cancer death of women in the United States, so breast cancer screening for early detection is common. The purpose of this dissertation is to optimize quantitative ultrasound (QUS) methods to improve the specificity and objectivity of breast ultrasound. To pursue this goal, the dissertation is divided into two parts: 1) to optimize 2D QUS, and 2) to introduce and validate 3D QUS. Previous studies had validated these methods in phantoms. Applying our QUS analysis on subcutaneous breast fat demonstrated that QUS parameter estimates for subcutaneous fat were consistent among different human subjects. This validated our in vivo data acquisition methods and supported the use of breast fat as a clinical reference tissue for ultrasound BI-RADSRTM assessments. Although current QUS methods perform well for straightforward cases when assumptions of stationarity and diffuse scattering are well-founded, these conditions often are not present due to the complicated nature of in vivo breast tissue. Key improvements in QUS algorithms to address these challenges were: 1) applying a "modified least squares method (MLSM)" to account for the heterogeneous tissue path between the transducer and the region of interest, ROI; 2) detecting anisotropy in acoustic parameters; and 3) detecting and removing the echo sources that depart from diffuse and stationary scattering conditions. The results showed that a Bayesian classifier combining three QUS parameters in a biased pool of high-quality breast ultrasound data successfully differentiated all fibroadenomas from all carcinomas. Given promising initial results in 2D, extension to 3D acquisitions in QUS provided a unique capability to test QUS for the entire breast volume. QUS parameter estimates using 3D data were consistent with those found in 2D for phantoms and in vivo data. Extensions of QUS technology from 2D to 3D can improve the specificity of breast ultrasound, and thus, could lead to

  7. Outcomes With Transcatheter Mitral Valve Repair in the United States: An STS/ACC TVT Registry Report.

    PubMed

    Sorajja, Paul; Vemulapalli, Sreekanth; Feldman, Ted; Mack, Michael; Holmes, David R; Stebbins, Amanda; Kar, Saibal; Thourani, Vinod; Ailawadi, Gorav

    2017-11-07

    Post-market surveillance is needed to evaluate the real-world clinical effectiveness and safety of U.S. Food and Drug Administration-approved devices. The authors examined the commercial experience with transcatheter mitral valve repair for the treatment of mitral regurgitation. Data from the Society of Thoracic Surgery/American College of Cardiology Transcatheter Valve Therapy Registry on patients commercially treated with transcatheter mitral valve repair were analyzed. The study population consisted of 2,952 patients treated at 145 hospitals between November 2013 and September 2015. In 1,867 patients, data were linked to patient-specific Centers for Medicare and Medicaid Services administrative claims for analyses. The median age was 82 years (55.8% men), with a median Society of Thoracic Surgery predicted risk of mortality of 6.1% (interquartile range: 3.7% to 9.9%) and 9.2% (interquartile range: 6.0% to 14.1%) for mitral repair and replacement, respectively. Overall, in-hospital mortality was 2.7%. Acute procedure success occurred in 91.8%. Among the patients with Centers for Medicare and Medicaid Services linkage data, the mortality at 30 days and at 1 year was 5.2% and 25.8%, respectively, and repeat hospitalization for heart failure at 1 year occurred in 20.2%. Variables associated with mortality or rehospitalization for heart failure after multivariate adjustment were increasing age, lower baseline left ventricular ejection fraction, worse post-procedural mitral regurgitation, moderate or severe lung disease, dialysis, and severe tricuspid regurgitation. Our findings demonstrate that commercial transcatheter mitral valve repair is being performed in the United States with acute effectiveness and safety. Our findings may help determine which patients have favorable long-term outcomes with this therapy. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  8. Revisiting Sex Equality With Transcatheter Aortic Valve Replacement Outcomes: A Collaborative, Patient-Level Meta-Analysis of 11,310 Patients.

    PubMed

    O'Connor, Stephen A; Morice, Marie-Claude; Gilard, Martine; Leon, Martin B; Webb, John G; Dvir, Danny; Rodés-Cabau, Josep; Tamburino, Corrado; Capodanno, Davide; D'Ascenzo, Fabrizio; Garot, Philippe; Chevalier, Bernard; Mikhail, Ghada W; Ludman, Peter F

    2015-07-21

    There has been conflicting clinical evidence as to the influence of female sex on outcomes after transcatheter aortic valve replacement. The aim of this study was to evaluate the impact of sex on early and late mortality and safety end points after transcatheter aortic valve replacement using a collaborative meta-analysis of patient-level data. From the MEDLINE, Embase, and the Cochrane Library databases, data were obtained from 5 studies, and a database containing individual patient-level time-to-event data was generated from the registry of each selected study. The primary outcome of interest was all-cause mortality. The safety end point was the combined 30-day safety end points of major vascular complications, bleeding events, and stroke, as defined by the Valve Academic Research Consortium when available. Five studies and their ongoing registry data, comprising 11,310 patients, were included. Women constituted 48.6% of the cohort and had fewer comorbidities than men. Women had a higher rate of major vascular complications (6.3% vs. 3.4%; p < 0.001), major bleeding events (10.5% vs. 8.5%; p = 0.003), and stroke (4.4% vs. 3.6%; p = 0.029) but a lower rate of significant aortic incompetence (grade ≥2; 19.4% vs. 24.5%; p < 0.001). There were no differences in procedural and 30-day mortality between women and men (2.6 % vs. 2.2% [p = 0.24] and 6.5% vs. 6.5% [p = 0.93], respectively), but female sex was independently associated with improved survival at median follow-up of 387 days (interquartile range: 192 to 730 days) from the index procedure (adjusted hazard ratio: 0.79; 95% confidence interval: 0.73 to 0.86; p = 0.001). Although women experience more bleeding events, as well as vascular and stroke complications, female sex is an independent predictor of late survival after transcatheter aortic valve replacement. This should be taken into account during patient selection for this procedure. Copyright © 2015 American College of Cardiology Foundation

  9. Antitumor activity of 3,4-ethylenedioxythiophene derivatives and quantitative structure-activity relationship analysis

    NASA Astrophysics Data System (ADS)

    Jukić, Marijana; Rastija, Vesna; Opačak-Bernardi, Teuta; Stolić, Ivana; Krstulović, Luka; Bajić, Miroslav; Glavaš-Obrovac, Ljubica

    2017-04-01

    The aim of this study was to evaluate nine newly synthesized amidine derivatives of 3,4- ethylenedioxythiophene (3,4-EDOT) for their cytotoxic activity against a panel of human cancer cell lines and to perform a quantitative structure-activity relationship (QSAR) analysis for the antitumor activity of a total of 27 3,4-ethylenedioxythiophene derivatives. Induction of apoptosis was investigated on the selected compounds, along with delivery options for the optimization of activity. The best obtained QSAR models include the following group of descriptors: BCUT, WHIM, 2D autocorrelations, 3D-MoRSE, GETAWAY descriptors, 2D frequency fingerprint and information indices. Obtained QSAR models should be relieved in elucidation of important physicochemical and structural requirements for this biological activity. Highly potent molecules have a symmetrical arrangement of substituents along the x axis, high frequency of distance between N and O atoms at topological distance 9, as well as between C and N atoms at topological distance 10, and more C atoms located at topological distances 6 and 3. Based on the conclusion given in the QSAR analysis, a new compound with possible great activity was proposed.

  10. The utility of trans-catheter aortic valve replacement after commercialization: does the European experience provide a glimpse into the future use of this technology in the United States?

    PubMed

    Linke, Axel; Walther, Thomas; Schuler, Gerhard

    2010-03-01

    Treatment of aortic stenosis remains challenging in older individuals, as their perioperative mortality for open heart surgery is increased due to comorbidities. Transcatheter aortic valve implantation using the CoreValve ReValving System (Medtronic, Minneapolis, USA) and the Edwards SAPIEN transcatheter heart valve (THV; Edwards Lifescience, Irvine, California, USA) represents an alternative to conventional valve replacement in elderly patients that have a high risk for conventional surgery. This article summarizes the evidence-base from recent clinical trials. The early results of these landmark studies suggest that transcatheter aortic valve implantation with either one of the prosthesis is feasible, safe, improves hemodynamics and, therefore, might be an alternative to conventional aortic valve replacement in very high-risk patients. However, all of the available transcatheter heart valves have certain disadvantages, limiting their use in daily clinical practice. The process of decision making, which valve to use and which access route to choose is illustrated in this article through clinical case scenarios. Additionally, the lessons learned thus far from the European perspective and the potential impact on the future use in the US are discussed. Despite of the progress in this field, we are still lacking an optimal transcatheter heart valve. Once it is available, we can take the plunge to compare transcatheter valve implantation with convention surgery in severe aortic stenosis!

  11. A spatiotemporal-based scheme for efficient registration-based segmentation of thoracic 4-D MRI.

    PubMed

    Yang, Y; Van Reeth, E; Poh, C L; Tan, C H; Tham, I W K

    2014-05-01

    Dynamic three-dimensional (3-D) (four-dimensional, 4-D) magnetic resonance (MR) imaging is gaining importance in the study of pulmonary motion for respiratory diseases and pulmonary tumor motion for radiotherapy. To perform quantitative analysis using 4-D MR images, segmentation of anatomical structures such as the lung and pulmonary tumor is required. Manual segmentation of entire thoracic 4-D MRI data that typically contains many 3-D volumes acquired over several breathing cycles is extremely tedious, time consuming, and suffers high user variability. This requires the development of new automated segmentation schemes for 4-D MRI data segmentation. Registration-based segmentation technique that uses automatic registration methods for segmentation has been shown to be an accurate method to segment structures for 4-D data series. However, directly applying registration-based segmentation to segment 4-D MRI series lacks efficiency. Here we propose an automated 4-D registration-based segmentation scheme that is based on spatiotemporal information for the segmentation of thoracic 4-D MR lung images. The proposed scheme saved up to 95% of computation amount while achieving comparable accurate segmentations compared to directly applying registration-based segmentation to 4-D dataset. The scheme facilitates rapid 3-D/4-D visualization of the lung and tumor motion and potentially the tracking of tumor during radiation delivery.

  12. Repeat transcatheter aortic valve implantation using a latest generation balloon-expandable device for treatment of failing transcatheter heart valves.

    PubMed

    Schaefer, Andreas; Treede, Hendrik; Seiffert, Moritz; Deuschl, Florian; Schofer, Niklas; Schneeberger, Yvonne; Blankenberg, Stefan; Reichenspurner, Hermann; Schaefer, Ulrich; Conradi, Lenard

    2016-01-15

    Paravalvular leakage (PVL) is a known complication of transcatheter aortic valve implantation (TAVI) and is associated with poor outcome. Besides balloon-post-dilatation, valve-in-valve (ViV) procedures can be taken into consideration to control this complication. Herein we present initial experience with use of the latest generation balloon-expandable Edwards Sapien 3® (S3) transcatheter heart valve (THV) for treatment of failing THVs. Between 01/2014 and 12/2014 three patients (two male, age: 71-80 y, log EUROScore I: 11.89 - 32.63) with failing THVs were refered to our institution for further treatment. THV approach with secondary implantation of an S3 was chosen after mutual agreement of the local interdisciplinary heart team at an interval of 533-1119 days from the index procedure. The performed procedures consisted of: S3 in Sapien XT, JenaValve and CoreValve. Successful transfemoral implantation with significant reduction of PVL was achieved in all cases. No intraprocedural complications occurred regarding placement of the S3 with a postprocedural effective orifice area (EOA) of 1.5-2.5 cm(2) and pressure gradients of max/mean 14/6-36/16 mmHg. 30-day mortality was 0%. At the latest follow-up of 90-530 days, all patients are alive and well with satisfactory THV function. Regarding VARC-2 criteria one major bleeding and one TIA was reported. In the instance of moderate or severe aortic regurgitation after TAVI, S3 ViV deployment is an excellent option to reduce residual regurgitation to none or mild. For further assertions concerning functional outcomes long-term results have to be awaited.

  13. Elevation of D4 dopamine receptor mRNA in postmortem schizophrenic brain.

    PubMed

    Stefanis, N C; Bresnick, J N; Kerwin, R W; Schofield, W N; McAllister, G

    1998-01-01

    The D4 dopamine (DA) receptor has been proposed to be a target for the development of a novel antipsychotic drug based on its pharmacological and distribution profile. There is much interest in whether D4 DA receptor levels are altered in schizophrenia, but the lack of an available receptor subtype-specific radioligand made this difficult to quantitate. In this study, we examined whether D4 mRNA levels are altered in different brain regions of schizophrenics compared to controls. Ribonuclease protection assays were carried out on total RNA samples isolated postmortem from frontal cortex and caudate brain regions of schizophrenics and matched controls. 32P-labelled RNA probes to the D4 DA receptor and to the housekeeping gene, glyceraldehyde-3-phosphate dehydrogenase (G3PDH), were hybridised with the RNA samples, digested with ribonucleases to remove unhybridised probe, and separated on 6% sequencing gels. Densitometer analysis on the subsequent autoradiogams was used to calculate the relative optical density of D4 mRNA compared to G3PDH mRNA. Statistical analysis of the data revealed a 3-fold higher level (P<0.011) of D4 mRNA in the frontal cortex of schizophrenics compared to controls. No increase was seen in caudate. D4 receptors could play a role in mediating dopaminergic activity in frontal cortex, an activity which may be malfunctioning in schizophrenia.

  14. Contemporary Costs Associated With Transcatheter Aortic Valve Replacement: A Propensity-Matched Cost Analysis.

    PubMed

    Ailawadi, Gorav; LaPar, Damien J; Speir, Alan M; Ghanta, Ravi K; Yarboro, Leora T; Crosby, Ivan K; Lim, D Scott; Quader, Mohammed A; Rich, Jeffrey B

    2016-01-01

    The Placement of Aortic Transcatheter Valve (PARTNER) trial suggested an economic advantage for transcatheter aortic valve replacement (TAVR) for high-risk patients. The purpose of this study was to evaluate the cost effectiveness of TAVR in the "real world" by comparing TAVR with surgical aortic valve replacement (SAVR) in intermediate-risk and high-risk patients. A multiinstitutional database of The Society of Thoracic Surgeons (STS) (2011 to 2013) linked with estimated cost data was evaluated for isolated TAVR and SAVR operations (n = 5,578). TAVR-treated patients (n = 340) were 1:1 propensity matched with SAVR-treated patients (n = 340). Patients undergoing SAVR were further stratified into intermediate-risk (SAVR-IR: predicted risk of mortality [PROM] 4% to 8%) and high-risk (SAVR-HR: PROM >8%) cohorts. Median STS PROM for TAVR was 6.32% compared with 6.30% for SAVR (SAVR-IR 4.6% and SAVR-HR 12.4%). A transfemoral TAVR approach was most common (61%). Mortality was higher for TAVR (10%) compared with SAVR (6%, p < 0.047), whereas the SAVR group accrued higher major morbidity (27% vs 14%, p < 0.001) and longer postoperative hospital duration (7 days vs 6 days, p < 0.001). Importantly, TAVR incurred twice the median total costs compared with SAVR ($69,921 vs $33,598, p < 0.001). The increased cost of TAVR was largely driven by the cost of the valve (all p < 0.001). Intermediate-risk patients undergoing SAVR demonstrated the most exaggerated cost savings versus TAVR. TAVR was associated with greater total costs and mortality compared with SAVR in intermediate-risk and high-risk patients while conferring lower major morbidity and improved resource use. Increased cost of TAVR appears largely related to the cost of the valve. Until the price of TAVR valves decreases, these data suggest that TAVR may not provide the most cost-effective strategy, particularly for intermediate-risk patients. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc

  15. Predictors of transient left ventricular dysfunction following transcatheter patent ductus arteriosus closure in pediatric age.

    PubMed

    Agha, Hala Mounir; Hamza, Hala S; Kotby, Alyaa; Ganzoury, Mona E L; Soliman, Nanies

    2017-10-01

    To evaluate the left ventricular function before and after transcatheter percutaneous patent ductus arteriosus (PDA) closure, and to identify the predictors of myocardial dysfunction post-PDA closure if present. Transcatheter PDA closure; conventional, Doppler, and tissue Doppler imaging; and speckle tracking echocardiography. To determine the feasibility and reliability of tissue Doppler and myocardial deformation imaging for evaluating myocardial function in children undergoing transcatheter PDA closure. Forty-two children diagnosed with hemodynamically significant PDA underwent percutaneous PDA closure. Conventional, Doppler, and tissue Doppler imaging, and speckle-derived strain rate echocardiography were performed at preclosure and at 48 hours, 1 month, and 6 months postclosure. Tissue Doppler velocities of the lateral and septal mitral valve annuli were obtained. Global and regional longitudinal peak systolic strain values were determined using two-dimensional speckle tracking echocardiography. The median age of the patients was 2 years and body weight was 15 kg, with the mean PDA diameter of 3.11 ± 0.99 mm. M-mode measurements (left ventricular end diastolic diameter, left atrium diameter to aortic annulus ratio, ejection fraction, and shortening fraction) reduced significantly early after PDA closure ( p  < 0.001). After 1 month, left ventricular end diastolic diameter and left atrium diameter to aortic annulus ratio continued to decrease, while ejection fraction and fractional shortening improved significantly. All tissue Doppler velocities showed a significant decrease at 48 hours with significant prolongation of global myocardial function ( p  < 0.001) and then were normalized within 1 month postclosure. Similarly, global longitudinal strain significantly decreased at 48 hours postclosure ( p  < 0.001), which also recovered at 1 month follow-up. Preclosure global longitudinal strain showed a good correlation with the postclosure

  16. Robust model-based 3d/3D fusion using sparse matching for minimally invasive surgery.

    PubMed

    Neumann, Dominik; Grbic, Sasa; John, Matthias; Navab, Nassir; Hornegger, Joachim; Ionasec, Razvan

    2013-01-01

    Classical surgery is being disrupted by minimally invasive and transcatheter procedures. As there is no direct view or access to the affected anatomy, advanced imaging techniques such as 3D C-arm CT and C-arm fluoroscopy are routinely used for intra-operative guidance. However, intra-operative modalities have limited image quality of the soft tissue and a reliable assessment of the cardiac anatomy can only be made by injecting contrast agent, which is harmful to the patient and requires complex acquisition protocols. We propose a novel sparse matching approach for fusing high quality pre-operative CT and non-contrasted, non-gated intra-operative C-arm CT by utilizing robust machine learning and numerical optimization techniques. Thus, high-quality patient-specific models can be extracted from the pre-operative CT and mapped to the intra-operative imaging environment to guide minimally invasive procedures. Extensive quantitative experiments demonstrate that our model-based fusion approach has an average execution time of 2.9 s, while the accuracy lies within expert user confidence intervals.

  17. Multicomponent cardiac rehabilitation in patients after transcatheter aortic valve implantation: Predictors of functional and psychocognitive recovery.

    PubMed

    Eichler, Sarah; Salzwedel, Annett; Reibis, Rona; Nothroff, Jörg; Harnath, Axel; Schikora, Martin; Butter, Christian; Wegscheider, Karl; Völler, Heinz

    2017-02-01

    Background In the last decade, transcatheter aortic valve implantation has become a promising treatment modality for patients with aortic stenosis and a high surgical risk. Little is known about influencing factors of function and quality of life during multicomponent cardiac rehabilitation. Methods From October 2013 to July 2015, patients with elective transcatheter aortic valve implantation and a subsequent inpatient cardiac rehabilitation were enrolled in the prospective cohort multicentre study. Frailty-Index (including cognition, nutrition, autonomy and mobility), Short Form-12 (SF-12), six-minute walk distance (6MWD) and maximum work load in bicycle ergometry were performed at admission and discharge of cardiac rehabilitation. The relation between patient characteristics and improvements in 6MWD, maximum work load or SF-12 scales were studied univariately and multivariately using regression models. Results One hundred and thirty-six patients (80.6 ± 5.0 years, 47.8% male) were enrolled. 6MWD and maximum work load increased by 56.3 ± 65.3 m ( p < 0.001) and 8.0 ± 14.9 watts ( p < 0.001), respectively. An improvement in SF-12 (physical 2.5 ± 8.7, p = 0.001, mental 3.4 ± 10.2, p = 0.003) could be observed. In multivariate analysis, age and higher education were significantly associated with a reduced 6MWD, whereas cognition and obesity showed a positive predictive value. Higher cognition, nutrition and autonomy positively influenced the physical scale of SF-12. Additionally, the baseline values of SF-12 had an inverse impact on the change during cardiac rehabilitation. Conclusions Cardiac rehabilitation can improve functional capacity as well as quality of life and reduce frailty in patients after transcatheter aortic valve implantation. An individually tailored therapy with special consideration of cognition and nutrition is needed to maintain autonomy and empower octogenarians in coping with challenges of everyday

  18. Annual Outcomes With Transcatheter Valve Therapy: From the STS/ACC TVT Registry.

    PubMed

    Holmes, David R; Nishimura, Rick A; Grover, Frederick L; Brindis, Ralph G; Carroll, John D; Edwards, Fred H; Peterson, Eric D; Rumsfeld, John S; Shahian, David M; Thourani, Vinod H; Tuzcu, E Murat; Vemulapalli, Sreekanth; Hewitt, Kathleen; Michaels, Joan; Fitzgerald, Susan; Mack, Michael J

    2016-02-01

    The Society of Thoracic Surgeons (STS)/American College of Cardiology (ACC) Transcatheter Valve Therapy (TVT) Registry has been a joint initiative of the STS and the ACC in concert with multiple stakeholders. The TVT Registry has important information regarding patient selection, delivery of care, science, education, and research in the field of structural valvular heart disease. This report provides an overview on current U.S. TVT practice and trends. The emphasis is on demographics, in-hospital procedural characteristics, and outcomes of patients having transcatheter aortic valve replacement (TAVR) performed at 348 U.S. centers. The TVT Registry captured 26,414 TAVR procedures as of December 31, 2014. Temporal trends between 2012 and 2013 versus 2014 were compared. Comparison of the 2 time periods reveals that TAVR patients remain elderly (mean age 82 years), with multiple comorbidities, reflected by a high mean STS predicted risk of mortality (STS PROM) for surgical valve replacement (8.34%), were highly symptomatic (New York Heart Association functional class III/IV in 82.5%), frail (slow 5-m walk test in 81.6%), and have poor self-reported health status (median baseline Kansas City Cardiomyopathy Questionnaire score of 39.1). Procedure performance is changing, with an increased use of moderate sedation (from 1.6% to 5.1%) and increase in femoral access using percutaneous techniques (66.8% in 2014). Vascular complication rates are decreasing (from 5.6% to 4.2%), whereas site-reported stroke rates remain stable at 2.2%. The TVT Registry provides important information on characteristics and outcomes of TAVR in contemporary U.S. clinical practice. It can be used to identify trends in practice and opportunities for quality improvement.

  19. Improvement of tricuspid regurgitation after transcatheter ASD closure in older patients.

    PubMed

    Chen, L; Shen, J; Shan, X; Wang, F; Kan, T; Tang, X; Zhao, X; Qin, Y

    2017-07-19

    Adult patients with undiagnosed atrial septal defect (ASD) may have right heart cavity enlargement and functional tricuspid valve insufficiency. Moderate or more severe tricuspid regurgitation has been associated with a worse prognosis, and more serious complications are typically seen in older patients. This study aimed to evaluate the improvement in functional tricuspid regurgitation and heart geometry after transcatheter ASD closure in older patients. The data of 111 patients over 60 years of age with moderate or severe tricuspid regurgitation before ASD closure were analyzed. At the 1‑month and 6‑month follow-up after closure, both tricuspid regurgitation jet area and right atrial volume decreased significantly. Right ventricular volume decreased 1 month after closure, showing a further decrease at the end of the 6‑month follow-up. However, 24 patients (21.6%) still had persistent severe tricuspid regurgitation after the procedure. Multivariate analysis revealed that patient age at ASD closure and pulmonary artery systolic pressure determined by echocardiography before closure were predictors of persistent tricuspid regurgitation after closure. Transcatheter ASD closure in older patients could significantly decrease tricuspid regurgitation and improve right heart geometry.

  20. Distortions in 2p4d Partial Fluorescence yield for 4d elements

    NASA Astrophysics Data System (ADS)

    Price, Alexander; de Groot, Frank; Datta, Trinanjan

    2014-03-01

    X-ray absorption spectroscopy (XAS) is a standard tool to determine the electronic structure of molecules and materials. CTM4XAS and CTM4RIXS are semi-empirical programs to analyze transition metal L - and M - edge transitions by evaluating the effects of crystal field and charge transfer parameters on the atomic multiplets. We compute and compare the XAS and the fluorescence yield (FY) XAS, of the 3d and 4d transition metal ions. In the case of 2p edges of 3d elements Auger decay dominates and sets the time scale. The 2p3d X -ray emission spectra (XES) accounts for approximately 80% of the radiative decay. The 2p3d partial FY is distorted and because it dominates the FY, the total FY is also distorted. For the 4d elements the 2p4d XES decay is approximately 10% of 2p3d XES decay, implying that (the energy-constant) core-core XES and Auger channels dominate the decay. The computed 2p4d partial FY -XAS spectra are different from the 2p XAS. Although 2p4d partial FY is distorted, the total FY is not because it is dominated by 2p3d XES. We also find that the 2p3s and 2p4s XES channels contribute less than 1% and can be neglected. Cottrell Research Corporation.

  1. Transcatheter Arterial Embolization of Angiographically Visible and Occult Renal Capsular Artery Hemorrhage in 28 Patients.

    PubMed

    Park, Hyo Jung; Shin, Ji Hoon; Han, Ki-Chang; Yoon, Hyun-Ki; Ko, Gi-Young; Sung, Kyu-Bo

    2016-07-01

    To evaluate the effectiveness and safety of transcatheter arterial embolization to control bleeding from the renal capsular artery (RCA). Embolization was performed in 28 patients (14 men; mean age, 49.7 y). Presence and type of previous invasive procedures, initial presentation, and coagulation profile were reviewed. Any preceding abdominal computed tomography (CT) findings were analyzed. Angiographic findings were categorized as active bleeding, suspicious for bleeding, or no bleeding. Technical and clinical success and clinical outcomes were evaluated. Changes in hemoglobin level and transfusion volume of packed red blood cells (pBRCs) before and after embolization were evaluated with the paired t test and Wilcoxon signed-rank test, respectively. Technical and clinical success rates of therapeutic embolization for active bleeding (n = 11) were 90.9% and 80%, respectively. One case of technical failure (5.9%) and 3 cases of postembolization bleeding (18.7%) were noted in the prophylactic embolization group in patients with suspicion of bleeding (n = 13) or no bleeding (n = 4). Transient renal insufficiency occurred in 4 patients (14.3%). The average hemoglobin level and volume of transfused pBRCs changed from 8.1 g/dL to 9.9 g/dL and from 871 mL to 543 mL, respectively (P < .05). Extravasation of contrast media or acute hematoma in the right subhepatic or perirenal space on CT was noted in 21 patients (78%). Embolization can provide an effective and safe method to control RCA bleeding. Perirenal invasive procedures and signs of active or recent right subhepatic or perirenal hemorrhage should raise the suspicion of an RCA source. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  2. Relationship of aortic annular eccentricity and paravalvular regurgitation post transcatheter aortic valve implantation with CoreValve.

    PubMed

    Wong, Dennis T L; Bertaso, Angela G; Liew, Gary Y H; Thomson, Viji S; Cunnington, Michael S; Richardson, James D; Gooley, Robert; Lockwood, Siobhan; Meredith, Ian T; Worthley, Matthew I; Worthley, Stephen G

    2013-04-01

    Significant paravalvular aortic regurgitation (PAR) after transcatheter aortic valve implantation (TAVI) is associated with negative clinical consequences. We hypothesize that increased eccentricity of the aortic annulus is associated with greater PAR. Patients with severe aortic stenosis underwent multidetector computed tomography (MDCT) before successful TAVI with the Medtronic CoreValve bioprosthesis. The smallest (D(min)) and largest (D(max)) orthogonal diameters in the basal ring of the aortic annulus were determined. We defined circularity of aortic annulus using the eccentricity index (1 - D(min)/D(max)). The primary endpoint was early occurrence of significant PAR, defined as > grade II PAR by postprocedural aortography. Eighty-four patients, mean age 83 ± 4 years with a mean aortic valve area of 0.7 ± 0.2 cm² were included. Twenty patients had postprocedural PAR > grade II. Using a receiver operating characteristic (ROC) analysis, eccentricity index correlated with significant PAR (AUC = 0.834; P=.034). A retrospectively determined eccentricity index cut-off of >0.25 was related to significant PAR with a sensitivity of 80%, specificity of 86%, and negative predictive value of 95% (P<.001). On univariate logistic regression, eccentricity index of >0.25 (P<.001) and device implantation depth (P=.015) correlated with significant PAR, while other parameters such as annular calcification and cover index did not. On multivariate analysis including only parameters with P<.1 on univariate analysis, eccentricity index >0.25 was the sole independent predictor of significant PAR. Eccentricity index is related to significant PAR after TAVI with Medtronic CoreValve. Further larger studies are required to determine the utility of this novel index in screening suitable patients for this procedure.

  3. Embolic capture with updated intra-aortic filter during coronary artery bypass grafting and transaortic transcatheter aortic valve implantation: first-in-human experience.

    PubMed

    Ye, Jian; Webb, John G

    2014-12-01

    We report our first-in-human clinical experience in the use of the new version of the EMBOL-X intra-aortic filter (Edwards Lifesciences Corporation, Irvine, Calif) to capture embolic material during transaortic transcatheter aortic valve implantation and cardiac surgery. Five patients were enrolled into the first-in-human clinical assessment of the new version of the EMBOL-X intra-aortic filter. Three patients underwent coronary artery bypass grafting, and 2 patients underwent transaortic transcatheter aortic valve implantation. During coronary artery bypass grafting, the filter was deployed before clamping of the aorta and removal of the aortic clamp. In contrast, the filter was deployed before aortic puncture for transaortic transcatheter aortic valve implantation and kept in the aorta throughout the entire procedure. The filter introducer sheath and filter were easily placed and removed without difficulty. There were no complications related to the use of the filter. Postoperative examination of the retrieved filters revealed the presence of multiple microemboli in the filters from all 5 cases. Histologic study revealed various kinds of tissue and thrombus. This first-in-human clinical experience has demonstrated the safety and feasibility of using the new version of the EMBOL-X intra-aortic filter during either cardiac surgery or transaortic transcatheter aortic valve implantation. We believe that the combination of the transaortic approach without aortic arch manipulation and the use of the EMBOL-X filter with a high capture rate is a promising strategy to reduce the incidence of embolic complications during transcatheter aortic valve implantation. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  4. Vitamin D4 in mushrooms.

    PubMed

    Phillips, Katherine M; Horst, Ronald L; Koszewski, Nicholas J; Simon, Ryan R

    2012-01-01

    An unknown vitamin D compound was observed in the HPLC-UV chromatogram of edible mushrooms in the course of analyzing vitamin D(2) as part of a food composition study and confirmed by liquid chromatography-mass spectrometry to be vitamin D(4) (22-dihydroergocalciferol). Vitamin D(4) was quantified by HPLC with UV detection, with vitamin [(3)H] itamin D(3) as an internal standard. White button, crimini, portabella, enoki, shiitake, maitake, oyster, morel, chanterelle, and UV-treated portabella mushrooms were analyzed, as four composites each of a total of 71 samples from U.S. retail suppliers and producers. Vitamin D(4) was present (>0.1 µg/100 g) in a total of 18 composites and in at least one composite of each mushroom type except white button. The level was highest in samples with known UV exposure: vitamin D enhanced portabella, and maitake mushrooms from one supplier (0.2-7.0 and 22.5-35.4 µg/100 g, respectively). Other mushrooms had detectable vitamin D(4) in some but not all samples. In one composite of oyster mushrooms the vitamin D(4) content was more than twice that of D(2) (6.29 vs. 2.59 µg/100 g). Vitamin D(4) exceeded 2 µg/100 g in the morel and chanterelle mushroom samples that contained D(4), but was undetectable in two morel samples. The vitamin D(4) precursor 22,23-dihydroergosterol was found in all composites (4.49-16.5 mg/100 g). Vitamin D(4) should be expected to occur in mushrooms exposed to UV light, such as commercially produced vitamin D enhanced products, wild grown mushrooms or other mushrooms receiving incidental exposure. Because vitamin D(4) coeluted with D(3) in the routine HPLC analysis of vitamin D(2) and an alternate mobile phase was necessary for resolution, researchers analyzing vitamin D(2) in mushrooms and using D(3) as an internal standard should verify that the system will resolve vitamins D(3) and D(4).

  5. Transcatheter closure of ventricular septal defects with nitinol wire occluders of type patent ductus arteriosus.

    PubMed

    Wierzyk, Arkadiusz; Szkutnik, Małgorzata; Fiszer, Roland; Banaszak, Paweł; Pawlak, Szymon; Białkowski, Jacek

    2014-01-01

    Ventricular septal defects closure (VSD) depending on the anatomy and clinical setting can be performed surgically or by a hybrid and transcatheter approach. Two cases of children with VSD will be presented. Patients' defects were closed with various types of occluders made of nitinol wire mesh occluder, patent ductus arteriosus (PDA) type. The first case was a 2.5-year-old boy after cardiosurgical correction of tetralogy of Fallot (TOF). After the procedure, a significant haemodynamic residual VSD was observed, which was not successfully closed during the subsequent reoperation. Despite pharmacological treatment, symptoms of heart failure were observed in this patient. In echocardiographic images the residual VSD was presented as a tunnel-like dissection of the ventricular septum (length 6 mm and diameter 3.4 mm). The defect was closed via arterial access with an Amplatzer Duct Occluder II (ADO II). The procedure was successfully performed without any medical complications. In this child, a significant shunt reduction and a noticeable improvement in the patient's clinical status and diminished symptoms of heart failure were noticed. The second patient was a 4-year-old girl suffering from a multi-perforated perimembranous VSD accompanied by a ventricular septal defect with aneurysm. The defect was closed by a venous approach with a PDA Cardio-O-Fix occluder (very similar to ADO I). No short-term or long-term complications were visible during or after the procedure. Only a mild residual shunt through the VSD was observed 6 months afterwards. Transcatheter VSD closure with a proper morphology, with occluders of type Amplatzer Duct Occluder ADO I or ADO II, constitutes a safe and effective therapeutic alternative.

  6. Retrospectively gated intracardiac 4D flow MRI using spiral trajectories.

    PubMed

    Petersson, Sven; Sigfridsson, Andreas; Dyverfeldt, Petter; Carlhäll, Carl-Johan; Ebbers, Tino

    2016-01-01

    To develop and evaluate retrospectively gated spiral readout four-dimensional (4D) flow MRI for intracardiac flow analysis. Retrospectively gated spiral 4D flow MRI was implemented on a 1.5-tesla scanner. The spiral sequence was compared against conventional Cartesian 4D flow (SENSE [sensitivity encoding] 2) in seven healthy volunteers and three patients (only spiral). In addition to comparing flow values, linear regression was used to assess internal consistency of aortic versus pulmonary net volume flows and left ventricular inflow versus outflow using quantitative pathlines analysis. Total scan time with spiral 4D flow was 44% ± 6% of the Cartesian counterpart (13 ± 3 vs. 31 ± 7 min). Aortic versus pulmonary flow correlated strongly for the spiral sequence (P < 0.05, slope = 1.03, R(2) = 0.88, N = 10), whereas the linear relationship for the Cartesian sequence was not significant (P = 0.06, N = 7). Pathlines analysis indicated good data quality for the spiral (P < 0.05, slope = 1.02, R(2) = 0.90, N = 10) and Cartesian sequence (P < 0.05, slope = 1.10, R(2) = 0.93, N = 7). Spiral and Cartesian peak flow rate (P < 0.05, slope = 0.96, R(2) = 0.72, N = 14), peak velocity (P < 0.05, slope = 1.00, R(2) = 0.81, N = 14), and pathlines flow components (P < 0.05, slope = 1.04, R(2) = 0.87, N = 28) correlated well. Retrospectively gated spiral 4D flow MRI permits more than two-fold reduction in scan time compared to conventional Cartesian 4D flow MRI, while maintaining similar data quality. © 2015 Wiley Periodicals, Inc.

  7. Transcatheter patent foramen ovale closure versus medical therapy for cryptogenic stroke: a meta-analysis of randomized clinical trials.

    PubMed

    Riaz, Irbaz Bin; Dhoble, Abhijeet; Mizyed, Ahmad; Hsu, Chiu-Hsieh; Husnain, Muhammad; Lee, Justin Z; Lotun, Kapildeo; Lee, Kwan S

    2013-12-11

    There is an association between cryptogenic stroke and patent foramen ovale (PFO). The optimal treatment strategy for secondary prevention remains unclear. The purpose of this study was to analyze aggregate data examining the safety and efficacy of transcatheter device closure versus standard medical therapy in patients with PFO and cryptogenic stroke. A search of published data identified 3 randomized clinical trials for inclusion. The primary outcome was a composite end-point of death, stroke and transient-ischemic attack (TIA). Pre-defined subgroup analysis was performed with respect to baseline characteristics including age, sex, atrial septal aneurysm and shunt size. Data was synthesized using a random effects model and results presented as hazard ratios (HRs) with 95% confidence intervals (CIs). A cohort of 2,303 patients with a history of cryptogenic stroke and PFO were randomized to device closure (n = 1150) and medical therapy (n = 1153). Mean follow-up was 2.5 years. Transcatheter closure was not superior to medical therapy in the secondary prevention of stroke or TIA in intention-to-treat analysis (HR: 0.66, 95% CI: 0.43 to 1.01; p = 0.056). However, the results were statistically significant using per-protocol analysis (HR: 0.64, 95% CI: 0.41 to 0.98; p = 0.043). Males had significant benefit with device closure (HR: 0.48, 95% CI: 0.24 to 0.96; p = 0.038). In this meta-analysis, using intention-to-treat analysis, transcatheter device closure of PFO was not superior to standard medical therapy in the secondary prevention of cryptogenic stroke. Transcatheter closure was superior using per-protocol analysis.

  8. Association of Tricuspid Regurgitation With Transcatheter Aortic Valve Replacement Outcomes: A Report From The Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry.

    PubMed

    McCarthy, Fenton H; Vemulapalli, Sreekanth; Li, Zhuokai; Thourani, Vinod; Matsouaka, Roland A; Desai, Nimesh D; Kirtane, Ajay; Anwaruddin, Saif; Williams, Matthew L; Giri, Jay; Vallabhajosyula, Prashanth; Li, Robert H; Herrmann, Howard C; Bavaria, Joseph E; Szeto, Wilson Y

    2018-04-01

    The purpose of this study is to evaluate the association of tricuspid regurgitation (TR) severity with outcomes after transcatheter aortic valve replacement (TAVR). We analyzed data from 34,576 patients who underwent TAVR at 365 US hospitals from November 2011 through March 2015 submitted to The Society of Thoracic Surgeon/American College of Cardiology Transcatheter Valve Therapy Registry. We examined unadjusted mortality and heart failure readmission stratified by degree of preoperative TR and used multivariable models for 1-year mortality and heart failure readmission. Tricuspid regurgitation was present in 80% (n = 27,804) of TAVR patients, with mild TR in 56% (n = 19,393), moderate TR in 19% (n = 6687), and severe TR in 5% (n = 1,724). Increasing TR severity was associated with a number of comorbidities and The Society of Thoracic Surgeons predicted risk of mortality increased (p < 0.001): no TR (7.3 ± 5.4); mild TR (8.0 ± 5.7); moderate TR (9.6 ± 6.8); and severe TR (10.7 ± 7.4). In unadjusted analysis, moderate and severe TR were associated with increased use of cardiopulmonary bypass, longer intensive care unit and hospital stays, new dialysis, inhospital major adverse cardiac event, inhospital mortality, observed-to-expected inhospital mortality ratio, long-term heart failure readmission, and mortality (p < 0.001). Adjusted mortality at 1 year was significantly worse for patients with severe TR when left ventricular ejection fraction greater than 30% (hazard ratio 1.29, 95% confidence interval: 1.11 to 1.50) as was heart failure readmission (hazard ratio 1.27, 95% confidence interval: 1.04 to 1.54). Tricuspid regurgitation was common among patients undergoing TAVR. Increasing TR severity was associated with higher risk patients and increased mortality and readmission-particularly for patients with severe TR and left ventricular ejection fraction greater than 30%. The effectiveness of TAVR alone in patients with aortic stenosis and concomitant

  9. Sequential transcatheter aortic valve implantation due to valve dislodgement - a Portico valve implanted over a CoreValve bioprosthesis.

    PubMed

    Campante Teles, Rui; Costa, Cátia; Almeida, Manuel; Brito, João; Sondergaard, Lars; Neves, José P; Abecasis, João; M Gabriel, Henrique

    2017-03-01

    Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected for surgery due to advanced age and comorbidities. The patient underwent a first TAVI, with implantation of a Medtronic CoreValve ® , which became dislodged and migrated to the ascending aorta. Due to the previous balloon valvuloplasty, the patient's AS became moderate, and her symptoms improved. After several months, she required another intervention, performed with a St. Jude Portico ® repositionable self-expanding transcatheter aortic valve. There was a good clinical response that was maintained at one-year follow-up. The use of a self-expanding transcatheter bioprosthesis with repositioning features is a solution in cases of valve dislocation to avoid suboptimal positioning of a second implant, especially when the two valves have to be positioned overlapping or partially overlapping each other. Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. 4D flow mri post-processing strategies for neuropathologies

    NASA Astrophysics Data System (ADS)

    Schrauben, Eric Mathew

    4D flow MRI allows for the measurement of a dynamic 3D velocity vector field. Blood flow velocities in large vascular territories can be qualitatively visualized with the added benefit of quantitative probing. Within cranial pathologies theorized to have vascular-based contributions or effects, 4D flow MRI provides a unique platform for comprehensive assessment of hemodynamic parameters. Targeted blood flow derived measurements, such as flow rate, pulsatility, retrograde flow, or wall shear stress may provide insight into the onset or characterization of more complex neuropathologies. Therefore, the thorough assessment of each parameter within the context of a given disease has important medical implications. Not surprisingly, the last decade has seen rapid growth in the use of 4D flow MRI. Data acquisition sequences are available to researchers on all major scanner platforms. However, the use has been limited mostly to small research trials. One major reason that has hindered the more widespread use and application in larger clinical trials is the complexity of the post-processing tasks and the lack of adequate tools for these tasks. Post-processing of 4D flow MRI must be semi-automated, fast, user-independent, robust, and reliably consistent for use in a clinical setting, within large patient studies, or across a multicenter trial. Development of proper post-processing methods coupled with systematic investigation in normal and patient populations pushes 4D flow MRI closer to clinical realization while elucidating potential underlying neuropathological origins. Within this framework, the work in this thesis assesses venous flow reproducibility and internal consistency in a healthy population. A preliminary analysis of venous flow parameters in healthy controls and multiple sclerosis patients is performed in a large study employing 4D flow MRI. These studies are performed in the context of the chronic cerebrospinal venous insufficiency hypothesis. Additionally, a

  11. Transcatheter Embolization for Delayed Hemorrhage Caused by Blunt Splenic Trauma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krohmer, Steven J., E-mail: Steven.J.Krohmer@hitchcock.org; Hoffer, Eric K., E-mail: eric.k.hoffer@hitchcock.or; Burchard, Kenneth W., E-mail: Kenneth.W.Burchard@hitchcock.or

    2010-08-15

    Although the exact benefit of adjunctive splenic artery embolization (SAE) in the nonoperative management (NOM) of patients with blunt splenic trauma has been debated, the role of transcatheter embolization in delayed splenic hemorrhage is rarely addressed. The purpose of this study was to evaluate the effectiveness of SAE in the management of patients who presented at least 3 days after initial splenic trauma with delayed hemorrhage. During a 24-month period 4 patients (all male; ages 19-49 years) presented with acute onset of pain 5-70 days after blunt trauma to the left upper quadrant. Two had known splenic injuries that hadmore » been managed nonoperatively. All had computed axial tomography evidence of active splenic hemorrhage or false aneurysm on representation. All underwent successful SAE. Follow-up ranged from 28 to 370 days. These cases and a review of the literature indicate that SAE is safe and effective for NOM failure caused by delayed manifestations of splenic arterial injury.« less

  12. A study on quantitative analysis of field size and dose by using gating system in 4D conformal radiation treatment

    NASA Astrophysics Data System (ADS)

    Ji, Youn-Sang; Dong, Kyung-Rae; Kim, Chang-Bok; Chung, Woon-Kwan; Cho, Jae-Hwan; Lee, Hae-Kag

    2012-10-01

    This study evaluated the gating-based 4-D conformal radiation therapy (4D-CT) treatment planning by a comparison with the common 3-D conformal radiation therapy (3D-CT) treatment planning and examined the change in treatment field size and dose to the tumors and adjacent normal tissues because an unnecessary dose is also included in the 3-D treatment planning for the radiation treatment of tumors in the chest and abdomen. The 3D-CT and gating-based 4D-CT images were obtained from patients who had undergone radiation treatment for chest and abdomen tumors in the oncology department. After establishing a treatment plan, the CT treatment and planning system were used to measure the change in field size for analysis. A dose volume histogram (DVH) was used to calculate the appropriate dose to planning target volume (PTV) tumors and adjacent normal tissue. The difference in the treatment volume of the chest was 0.6 and 0.83 cm on the X- and Y-axis, respectively, for the gross tumor volume (GTV). Accordingly, the values in the 4D-CT treatment planning were smaller and the dose was more concentrated by 2.7% and 0.9% on the GTV and clinical target volume (CTV), respectively. The normal tissues in the surrounding normal tissues were reduced by 3.0%, 7.2%, 0.4%, 1.7%, 2.6% and 0.2% in the bronchus, chest wall, esophagus, heart, lung and spinal cord, respectively. The difference in the treatment volume of the abdomen was 0.72 cm on the X-axis and 0.51 cm on the Y-axis for the GTV; and 1.06 cm on the X-axis and 1.85 cm on the Y-axis for the PTV. Therefore, the values in the 4D-CT treatment planning were smaller. The dose was concentrated by 6.8% and 4.3% on the GTV and PTV, respectively, whereas the adjacent normal tissues in the cord, Lt. kidney, Rt. kidney, small bowels and whole liver were reduced by 3.2%, 4.2%, 1.5%, 6.2% and 12.7%, respectively. The treatment field size was smaller in volume in the case of the 4D-CT treatment planning. In the DVH, the 4D-CT treatment

  13. Transcatheter closure of large patent ductus arteriosus with severe pulmonary arterial hypertension in adults: immediate and two-year follow-up results.

    PubMed

    Zhang, Cao-Jin; Huang, Yi-Gao; Huang, Xin-Sheng; Huang, Tao; Huang, Wen-Hui; Xia, Chun-Li; Mo, Yu-Jing

    2012-11-01

    Transcatheter closure of patent ductus arteriosus (PDA) is a well established procedure and an accepted treatment modality for small to moderate-sized PDA. This study aimed to evaluate the immediate and follow-up results of transcatheter closure of large PDAs with severe pulmonary arterial hypertension (PAH) in adults. After a complete hemodynamic evaluation differentiating from the reversibility of severe PAH, transcatheter closure of PDA was performed. Patients were followed up clinically and echocardiographically at 24 hours, 1 month, 3 months, 6 months, 12 months and 24 months after occlusion. Twenty-nine patients had successful occlusion, pulmonary artery pressure (PAP), left ventricular ejection fraction (LVEF) and fractional shortening (FS) significantly decreased immediately after occlusion ((106 ± 25) mmHg vs. (50 ± 14) mmHg, P < 0.01; (63.7 ± 7.2)% vs. (51.4 ± 10.1)%, P < 0.01 and (36.9 ± 8.2)% vs. (28.9 ± 8.6)%, P < 0.05, respectively). At 1 month after PDA closure, the signs and symptoms improved markedly in all 29 patients, and PDAs were completely closed and remained closed during the follow-up. Eighteen patients having different degrees of dyspnea were treated with angiotensin converting enzyme inhibitor (ACEI) and/or digoxin after occlusion. Nine patients whose pulmonary vascular resistence (PVR) > 6 Wood units accepted targeted PAH therapy. After 1 to 3 months of peroral drug therapy, their exercise tolerance improved from New York Heart Association (NYHA) class III-IV to NYHA class I. During follow-up, no latent arrhythmias were found, the left atrial diameter (LAD), left ventricular end-diastolic diameter (LVEDD), left ventricular end-systolic diameter (LVESD), left ventricular mass index (LVMI) and pulmonary artery systolic pressure (PASP) decreased significantly (P < 0.05), and FS and LVEF recovered compared to the immediate postclosure state. However, FS and LVEF remained low compared to the preclosure state. Transcatheter closure of

  14. Transcatheter embolization of pancreatic arteriovenous malformation associated with recurrent acute pancreatitis

    PubMed Central

    Rajesh, S; Mukund, Amar; Bhatia, Vikram; Arora, Ankur

    2016-01-01

    Pancreatic arteriovenous malformation (PAVM) is extremely rare; even rarer is its association with pancreatitis. The authors report a case of PAVM causing recurrent episodes of acute pancreatitis in a 46-year-old male. Patient refused surgery and was treated with transcatheter arterial embolization using liquid embolic agent (mixture of n-butyl-2-cyanoacrylate glue and lipiodol), which resulted in a significant decrease in the size of the PAVM. PMID:27081231

  15. Outcomes of patients with chronic lung disease and severe aortic stenosis treated with transcatheter versus surgical aortic valve replacement or standard therapy: insights from the PARTNER trial (placement of AoRTic TraNscathetER Valve).

    PubMed

    Dvir, Danny; Waksman, Ron; Barbash, Israel M; Kodali, Susheel K; Svensson, Lars G; Tuzcu, E Murat; Xu, Ke; Minha, Sa'ar; Alu, Maria C; Szeto, Wilson Y; Thourani, Vinod H; Makkar, Raj; Kapadia, Samir; Satler, Lowell F; Webb, John G; Leon, Martin B; Pichard, Augusto D

    2014-01-28

    The study aimed to evaluate the impact of chronic lung disease (CLD) on outcomes of severe aortic stenosis patients across all treatment modalities. Outcomes of patients with CLD undergoing transcatheter aortic valve replacement (TAVR) have not been systematically examined. All patients who underwent TAVR in the PARTNER (Placement of AoRTic TraNscathetER Valve) trial, including the continued access registry (n = 2,553; 1,108 with CLD), were evaluated according to CLD clinical severity. Additionally, outcomes of CLD patients included in the randomization arms of the PARTNER trial were compared: Cohort A patients (high-risk operable) treated by either TAVR (n = 149) or surgical aortic valve replacement (SAVR); (n = 138); and Cohort B patients (inoperable) treated by either TAVR (n = 72) or standard therapy only (n = 95). Among all TAVR-treated patients, at 1-year follow-up, patients with CLD had higher mortality than those without it (23.4% vs. 19.6%, p = 0.02). Baseline characteristics of CLD patients who underwent TAVR were similar to respective controls. In Cohort A, 2-year all-cause death rates were similar (TAVR 35.2% and SAVR 33.6%, p = 0.92), whereas in Cohort B, the death rate was lower after TAVR (52.0% vs. 69.6% after standard therapy only, p = 0.04). Independent predictors for mortality in CLD patients undergoing TAVR included poor mobility (6-min walk test <50 m; hazard ratio: 1.67, p = 0.0009) and oxygen-dependency (hazard ratio: 1.44, p = 0.02). Although CLD patients undergoing TAVR have worse outcomes than patients without CLD, TAVR is better in these patients than standard therapy and is similar to SAVR. Although patients with CLD undergoing TAVR had worse outcomes than patients without CLD, TAVR performed better in these patients than standard therapy and was similar to SAVR. However, CLD patients who were either poorly mobile or oxygen-dependent had poor outcomes. (THE PARTNER TRIAL: Placement of AoRTic TraNscathetER Valve Trial; NCT

  16. Trans-catheter aortic valve implantation after previous aortic homograft surgery.

    PubMed

    Drews, Thorsten; Pasic, Miralem; Buz, Semih; Unbehaun, Axel

    2011-12-01

    In patients with previous heart surgery, the operative risk is elevated during conventional aortic valve re-operations. Trans-catheter aortic valve implantation is a new method for the treatment of high-risk patients. Nevertheless, this new procedure carries potential risks in patients with previous homograft implantation in aortic position. Between April 2008 and February 2011, 345 consecutive patients (mean EuroSCORE (European System for Cardiac Operative Risk Evaluation): 38 ± 20%; mean Society of Thoracic Surgeons (STS) Mortality Score: 19 ± 16%; mean age: 80 ± 8 years; 111 men and 234 women) underwent trans-apical aortic valve implantation. In three patients, previous aortic homograft implantation had been performed. Homograft degeneration causing combined valve stenosis and incompetence made re-operation necessary. In all three patients, the aortic valve could be implanted using the trans-apical approach, and the procedure was successful. In two patients, there was slight paravalvular leakage of the aortic prosthesis and the other patient had slight central leakage. Neither ostium obstruction nor mitral valve damage was observed. Trans-catheter valve implantation can be performed successfully after previous homograft implantation. Particular care should be taken to achieve optimal valve positioning, not to obstruct the ostium of the coronary vessels due to the changed anatomic situation and not to cause annulus rupture. Copyright © 2011 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  17. Clinical outcomes of symptomatic arterioportal fistulas after transcatheter arterial embolization

    PubMed Central

    Hirakawa, Masakazu; Nishie, Akihiro; Asayama, Yoshiki; Ishigami, Kousei; Ushijima, Yasuhiro; Fujita, Nobuhiro; Honda, Hiroshi

    2013-01-01

    AIM: To evaluate the complications and clinical outcomes of transcatheter arterial embolization (TAE) for symptoms related to severe arterioportal fistulas (APFs). METHODS: Six patients (3 males, 3 females; mean age, 63.8 years; age range, 60-71 years) with chronic liver disease and severe APFs due to percutaneous intrahepatic treatment (n = 5) and portal vein (PV) tumor thrombosis of hepatocellular carcinoma (n = 1) underwent TAE for symptoms related to severe APFs [refractory ascites (n = 4), hemorrhoidal hemorrhage (n = 1), and hepatic encephalopathy (n = 1)]. Control of symptoms related to APFs and complications were evaluated during the follow-up period (range, 4-57 mo). RESULTS: In all patients, celiac angiography revealed immediate retrograde visualization of the main PV before TAE, indicating severe APF. Selective TAE for the hepatic arteries was performed using metallic coils (MC, n = 4) and both MCs and n-butyl cyanoacrylate (n = 2). Three patients underwent repeated TAEs for residual APFs and ascites. Four patients developed PV thrombosis after TAE. During the follow-up period after TAE, APF obliteration and symptomatic improvement were obtained in all patients. CONCLUSION: Although TAE for severe APFs may sometimes be complicated by PV thrombosis, TAE can be an effective treatment to improve clinical symptoms related to severe APFs. PMID:23494252

  18. Selective transcatheter embolization for treatment of post-traumatic hepatic artery and portal vein pseudoaneurysms.

    PubMed

    Laopaiboon, Vallop; Aphinives, Chalida; Pugkem, Ake; Thummaroj, Jureerat; Puttharak, Warinthorn; Soommart, Yamuna

    2006-02-01

    The authors report a case of post-traumatic hepatic artery and portal vein pseudoaneurysms caused by blunt abdominal trauma, with multiple organ injuries including liver laceration. Abdominal spiral CT, CDS and DSA were performed to confirm the diagnosis. Both pseudoaneurysms were treated successfully with selective transcatheter embolization.

  19. [Feasibility of device closure for multiple atrial septal defects using 3D printing and ultrasound-guided intervention technique].

    PubMed

    Qiu, X; Lü, B; Xu, N; Yan, C W; Ouyang, W B; Liu, Y; Zhang, F W; Yue, Z Q; Pang, K J; Pan, X B

    2017-04-25

    Objective: To investigate the feasibility of trans-catheter closure of multiple atrial septal defects (ASD) monitored by trans-thoracic echocardiography (TTE) under the guidance of 3D printing heart model. Methods: Between April and August 2016, a total of 21 patients (8 male and 13 female) with multiple ASD in Fuwai Hospital of Chinese Academy of Medical Sciences underwent CT scan and 3-dimensional echocardiography for heart disease model produced by 3D printing technique. The best occlusion program was determined through the simulation test on the model. Percutaneous device closure of multiple ASD was performed follow the predetermined program guided by TTE. Clinical follow-up including electrocardiogram and TTE was arranged at 1 month after the procedure. Results: The trans-catheter procedure was successful in all 21 patients using a single atrial septal occluder. Mild residual shunt was found in 5 patient in the immediate postoperative period, 3 of them were disappeared during postoperative follow-up. There was no death, vascular damage, arrhythmia, device migration, thromboembolism, valvular dysfunction during the follow-up period. Conclusion: The use of 3D printing heart model provides a useful reference for transcatheter device closure of multiple ASD achieving through ultrasound-guided intervention technique, which appears to be safe and feasible with good outcomes of short-term follow-up.

  20. The importance of echocardiography in transcatheter aortic valve implantation.

    PubMed

    Bilen, Emine; Sari, Cenk; Durmaz, Tahir; Keleş, Telat; Bayram, Nihal A; Akçay, Murat; Ayhan, Hüseyin M; Bozkurt, Engin

    2014-01-01

    Valvular heart diseases cause serious health problems in Turkey as well as in Western countries. According to a study conducted in Turkey, aortic stenosis (AS) is second after mitral valve disease among all valvular heart diseases. AS is frequently observed in elderly patients who have several cardiovascular risk factors and comorbidities. In symptomatic severe AS, surgical aortic valve replacement (AVR) is a definitive treatment. However, in elderly patients with left ventricular dysfunction and comorbidities, the risk of operative morbidity and mortality increases and outweighs the gain obtained from AVR surgery. As a result, almost one-third of the patients with serious AS are considered ineligible for surgery. Transcatheter aortic valve implantation (TAVI) is an effective treatment in patients with symptomatic severe AS who have high risk for conventional surgery. Since being performed for the first time in 2002, with a procedure success rate reported as 95% and a mortality rate of 5%, TAVI has become a promising method. Assessment of vascular anatomy, aortic annular diameter, and left ventricular function may be useful for the appropriate selection of patients and may reduce the risk of complications. Cardiac imaging methods including 2D and 3D echocardiography and multidetector computed tomography are critical during the evaluation of suitable patients for TAVI as well as during and after the procedure. In this review, we describe the role of echocardiography methods in clinical practice for TAVI procedure in its entirety, i.e. from patient selection to guidance during the procedure, and subsequent monitoring. © 2013, Wiley Periodicals, Inc.

  1. Annual Outcomes With Transcatheter Valve Therapy: From the STS/ACC TVT Registry.

    PubMed

    Holmes, David R; Nishimura, Rick A; Grover, Frederick L; Brindis, Ralph G; Carroll, John D; Edwards, Fred H; Peterson, Eric D; Rumsfeld, John S; Shahian, David M; Thourani, Vinod H; Tuzcu, E Murat; Vemulapalli, Sreekanth; Hewitt, Kathleen; Michaels, Joan; Fitzgerald, Susan; Mack, Michael J

    2015-12-29

    The Society of Thoracic Surgeons (STS)/American College of Cardiology (ACC) Transcatheter Valve Therapy (TVT) Registry has been a joint initiative of the STS and the ACC in concert with multiple stakeholders. The TVT Registry has important information regarding patient selection, delivery of care, science, education, and research in the field of structural valvular heart disease. This report provides an overview on current U.S. TVT practice and trends. The emphasis is on demographics, in-hospital procedural characteristics, and outcomes of patients having transcatheter aortic valve replacement (TAVR) performed at 348 U.S. centers. The TVT Registry captured 26,414 TAVR procedures as of December 31, 2014. Temporal trends between 2012 and 2013 versus 2014 were compared. Comparison of the 2 time periods reveals that TAVR patients remain elderly (mean age 82 years), with multiple comorbidities, reflected by a high mean STS predicted risk of mortality (STS PROM) for surgical valve replacement (8.34%), were highly symptomatic (New York Heart Association functional class III/IV in 82.5%), frail (slow 5-m walk test in 81.6%), and have poor self-reported health status (median baseline Kansas City Cardiomyopathy Questionnaire score of 39.1). Procedure performance is changing, with an increased use of moderate sedation (from 1.6% to 5.1%) and increase in femoral access using percutaneous techniques (66.8% in 2014). Vascular complication rates are decreasing (from 5.6% to 4.2%), whereas site-reported stroke rates remain stable at 2.2%. The TVT Registry provides important information on characteristics and outcomes of TAVR in contemporary U.S. clinical practice. It can be used to identify trends in practice and opportunities for quality improvement. Copyright © 2015 American College of Cardiology Foundation and The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Transcatheter mitral direct annuloplasty: state of the art.

    PubMed

    Maisano, F; Kuck, K H

    2014-06-01

    Transcatheter mitral interventions are emerging as a novel therapy for patients with severe symptomatic mitral regurgitation who are deemed to be high risk or inoperable. Surgical treatment of mitral regurgitation includes a wide spectrum of therapies, ranging from leaflet and annular repair, to mitral valve replacement. Annuloplasty plays a fundamental role in open heart mitral valve repair, since it is associated with longer durability and higher degree of mitral regurgitation reduction. Direct annuloplasty is the interventional methodology most closely reproducing open heart annular repair. We describe the challenges and opportunities of the most promising technologies currently under development which will become available in clinical practice in the next future.

  3. Imaging and transcatheter arterial embolization for traumatic splenic injuries: review of the literature.

    PubMed

    Raikhlin, Antony; Baerlocher, Mark Otto; Asch, Murray R; Myers, Andy

    2008-12-01

    The spleen is the most commonly injured visceral organ in blunt abdominal trauma in both adults and children. Nonoperative management is the current standard of practice for patients who are hemodynamically stable. However, simple observation alone has been reported to have a failure rate as high as 34%; the rate is even higher among patients with high-grade splenic injuries (American Association for the Surgery of Trauma [AAST] grade III-V). Over the past decade, angiography with transcatheter splenic artery embolization, an alternative nonoperative treatment for splenic injuries, has increased splenic salvage rates to as high as 97%. With the help of splenic artery embolization, success rates of more than 80% have also been described for high-grade splenic injuries. We discuss the role of computed tomography and transcatheter splenic artery embolization in the diagnosis and treatment of blunt splenic trauma. We review technical considerations, indications, efficacy and complication rates. We also propose an algorithm to guide the use of angiography and splenic embolization in patients with traumatic splenic injury.

  4. Imaging and transcatheter arterial embolization for traumatic splenic injuries: review of the literature

    PubMed Central

    Raikhlin, Antony; Baerlocher, Mark Otto; Asch, Murray R.; Myers, Andy

    2008-01-01

    The spleen is the most commonly injured visceral organ in blunt abdominal trauma in both adults and children. Nonoperative management is the current standard of practice for patients who are hemodynamically stable. However, simple observation alone has been reported to have a failure rate as high as 34%; the rate is even higher among patients with high-grade splenic injuries (American Association for the Surgery of Trauma [AAST] grade III–V). Over the past decade, angiography with transcatheter splenic artery embolization, an alternative nonoperative treatment for splenic injuries, has increased splenic salvage rates to as high as 97%. With the help of splenic artery embolization, success rates of more than 80% have also been described for high-grade splenic injuries. We discuss the role of computed tomography and transcatheter splenic artery embolization in the diagnosis and treatment of blunt splenic trauma. We review technical considerations, indications, efficacy and complication rates. We also propose an algorithm to guide the use of angiography and splenic embolization in patients with traumatic splenic injury. PMID:19057735

  5. Safety and efficacy of transcatheter closure of large patent ductus arteriosus in adults with a self-expandable occluder.

    PubMed

    Yu, Man-Li; Huang, Xin-Miao; Wang, Jia-Feng; Qin, Yong-Wen; Zhao, Xian-Xian; Zheng, Xing

    2009-11-01

    Most occurrences of large patent ductus arteriosus (PDAs) of > or =10 mm have been surgically closed, and transcatheter closure of these large PDAs was only reported in a few case reports. The present study reviewed our experience in transcatheter closure of such large PDAs with a Chinese self-expandable occluder, which is similar to but much cheaper than the Amplatzer occluder. From July 2000 to January 2008, 23 patients underwent transcatheter closure of large PDA > or =10 mm with this kind of occluder. The mean (SD) age of the patients was 38.0 (15.6) years (range 18-75 years). Radiographs of the chest, electrocardiograms, and echocardiograms were used for follow-up evaluation of the treatment within 1 day, 1 month, 6 months, and then every year after successful closure. The mean (SD) angiographic PDA diameter was 12.8 (2.6) mm (range 10-18 mm) and the mean occluder diameter was 18.0 (2.9) mm (range 16-22 mm). The occluders were delivered successfully and closed the PDA completely in 19 out of the 23 patients. Pulmonary arterial pressures decreased significantly after occlusion in patients with successful treatment: 67.3 (24.7) mmHg (range 29-122 mmHg) before occlusion and 42.3 (22.0) mmHg (range 19-98 mmHg) immediately after the procedure. Radiographs of the chest and echocardiograms showed that the diameters of the left atrium, left ventricle, and the main pulmonary artery decreased, and the ejection fraction (EF) increased at a mean (SD) follow-up of 36.3 (18.7) months (range 6-72 months). No severe complication occurred. The immediate and long-term outcomes suggested that transcatheter closure of PDAs with the native PDA occluder is a safe and effective treatment for adults with large PDA > or =10 mm.

  6. Impact of Mitral Regurgitation on Clinical Outcomes After Transcatheter Aortic Valve Implantation

    PubMed Central

    Tüller, David; Zbinden, Rainer; Eberli, Franz R

    2016-01-01

    Severe aortic stenosis (AS) and mitral regurgitation (MR) are the two most common valvular lesions referred for surgical intervention in Europe and frequently co-exist. In patients with both severe AS and significant MR referred for surgical aortic valve replacement (SAVR), a concomitant mitral valve intervention is typically performed if the MR is severe, despite the higher associated perioperative risk. The management of moderate MR among SAVR patients is controversial and depends on a number of factors including MR aetiology (i.e., organic versus functional MR), feasibility of repair and patient risk profile. Moderate or severe MR is present in up to one-third of patients undergoing transcatheter aortic valve implantation (TAVI), is mainly of functional aetiology and is typically left untreated. Although data are conflicting, a growing body of evidence suggests that significant MR exerts an adverse effect on both short- and long-term clinical outcomes after TAVI. Moderate or severe MR improves in just over half of patients following TAVI and recent data suggest MR is more likely to improve among patients receiving a balloon-expandable as compared with a self-expandable transcatheter heart valve. PMID:29588707

  7. Simultaneous quantitative analysis of eight vitamin D analogues in milk using liquid chromatography-tandem mass spectrometry.

    PubMed

    Gomes, Fabio P; Shaw, P Nicholas; Whitfield, Karen; Hewavitharana, Amitha K

    2015-09-03

    Milk is an important source of nutrients for various risk populations, including infants. The accurate measurement of vitamin D in milk is necessary to provide adequate supplementation advice for risk groups and to monitor regulatory compliance. Currently used liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods are capable of measuring only four analogues of vitamin D in unfortified milk. We report here an accurate quantitative analytical method for eight analogues of vitamin D: Vitamin D2 and D3 (D2 and D3), 25-hydroxy D2 and D3, 24,25-dihydroxy D2 and D3, and 1,25-dihydroxyD2 and D3. In this study, we compared saponification and protein precipitation for the extraction of vitamin D from milk and found the latter to be more effective. We also optimised the pre-column derivatisation using 4-phenyl-l,2,4-triazoline-3,5-dione (PTAD), to achieve the highest sensitivity and accuracy for all major vitamin D forms in milk. Chromatography was optimised to reduce matrix effects such as ion-suppression, and the matrix effects were eliminated using co-eluting stable isotope labelled internal standards for the calibration of each analogue. The analogues, 25-hydroxyD3 (25(OH)D3) and its epimer (3-epi-25(OH)D3) were chromatographically resolved, to prevent over-estimation of 25(OH)D3. The method was validated and subsequently applied for the measurement of total vitamin D levels in human, cow, mare, goat and sheep milk samples. The detection limits, repeatability standard deviations, and recovery ranges were from 0.2 to 0.4 femtomols, 6.30-13.5%, and 88.2-105%, respectively. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Transcatheter Aortic Valve Implantation in an Extremely Tortuous S-Shaped Aorta

    PubMed Central

    Toleva, Olga; Pozeg, Zlatko; Menkis, Alan

    2017-01-01

    Transcatheter aortic valve implantation (TAVI) has emerged as an alternative technique to treating aortic stenosis in patients with high surgical risk. We present a case of a successful transfemoral TAVI in a high-risk patient with an extremely tortuous iliofemoral system and a significant S-type bend in the descending aorta. With careful preprocedure planning and using all the techniques available, TAVI can be performed in the most challenging patients. PMID:28352480

  9. MyD88 and TLR4 Expression in Epithelial Ovarian Cancer

    PubMed Central

    Block, Matthew S.; Vierkant, Robert A.; Rambau, Peter F.; Winham, Stacey J.; Wagner, Philipp; Traficante, Nadia; Tołoczko, Aleksandra; Tiezzi, Daniel G.; Taran, Florin Andrei; Sinn, Peter; Sieh, Weiva; Sharma, Raghwa; Rothstein, Joseph H.; Cajal, Teresa Ramón y; Paz-Ares, Luis; Oszurek, Oleg; Orsulic, Sandra; Ness, Roberta B.; Nelson, Gregg; Modugno, Francesmary; Menkiszak, Janusz; McGuire, Valerie; McCauley, Bryan M.; Mack, Marie; Lubiński, Jan; Longacre, Teri A.; Li, Zheng; Lester, Jenny; Kennedy, Catherine J.; Kalli, Kimberly R.; Jung, Audrey Y.; Johnatty, Sharon E.; Jimenez-Linan, Mercedes; Jensen, Allan; Intermaggio, Maria P.; Hung, Jillian; Herpel, Esther; Hernandez, Brenda Y.; Hartkopf, Andreas D.; Harnett, Paul R.; Ghatage, Prafull; García-Bueno, José M.; Gao, Bo; Fereday, Sian; Eilber, Ursula; Edwards, Robert P.; de Sousa, Christiani B.; de Andrade, Jurandyr M.; Chudecka-Głaz, Anita; Chenevix-Trench, Georgia; Cazorla, Alicia; Brucker, Sara Y.; Alsop, Jennifer; Whittemore, Alice S.; Steed, Helen; Staebler, Annette; Moysich, Kirsten B.; Menon, Usha; Koziak, Jennifer M.; Kommoss, Stefan; Kjaer, Susanne K.; Kelemen, Linda E.; Karlan, Beth Y.; Huntsman, David G.; Høgdall, Estrid; Gronwald, Jacek; Goodman, Marc T.; Gilks, Blake; García, María José; Fasching, Peter A.; de Fazio, Anna; Deen, Suha; Chang-Claude, Jenny; Candido dos Reis, Francisco J.; Campbell, Ian G.; Brenton, James D.; Bowtell, David D.; Benítez, Javier; Pharoah, Paul D.P.; Köbel, Martin; Ramus, Susan J.; Goode, Ellen L.

    2018-01-01

    Objective To evaluate myeloid differentiation primary response gene 88 (MyD88) and Toll-like receptor 4 (TLR4) expression in relation to clinical features of epithelial ovarian cancer, histologic subtypes, and overall survival. Patients and Methods We conducted centralized immunohistochemical staining, semi-quantitative scoring, and survival analysis in 5263 patients participating in the Ovarian Tumor Tissue Analysis consortium. Patients were diagnosed between January 1, 1978, and December 31, 2014, including 2865 high-grade serous ovarian carcinomas (HGSOCs), with more than 12,000 person-years of follow-up time. Tissue microarrays were stained for MyD88 and TLR4, and staining intensity was classified using a 2-tiered system for each marker (weak vs strong). Results Expression of MyD88 and TLR4 was similar in all histotypes except clear cell ovarian cancer, which showed reduced expression compared with other histotypes (P<.001 for both). In HGSOC, strong MyD88 expression was modestly associated with shortened overall survival (hazard ratio [HR], 1.13; 95% CI, 1.01–1.26; P=.04) but was also associated with advanced stage (P<.001). The expression of TLR4 was not associated with survival. In low-grade serous ovarian cancer (LGSOC), strong expression of both MyD88 and TLR4 was associated with favorable survival (HR [95% CI], 0.49 [0.29–0.84] and 0.44 [0.21–0.89], respectively; P=.009 and P=.02, respectively). Conclusion Results are consistent with an association between strong MyD88 staining and advanced stage and poorer survival in HGSOC and demonstrate correlation between strong MyD88 and TLR4 staining and improved survival in LGSOC, highlighting the biological differences between the 2 serous histotypes. PMID:29502561

  10. MyD88 and TLR4 Expression in Epithelial Ovarian Cancer.

    PubMed

    Block, Matthew S; Vierkant, Robert A; Rambau, Peter F; Winham, Stacey J; Wagner, Philipp; Traficante, Nadia; Tołoczko, Aleksandra; Tiezzi, Daniel G; Taran, Florin Andrei; Sinn, Peter; Sieh, Weiva; Sharma, Raghwa; Rothstein, Joseph H; Ramón Y Cajal, Teresa; Paz-Ares, Luis; Oszurek, Oleg; Orsulic, Sandra; Ness, Roberta B; Nelson, Gregg; Modugno, Francesmary; Menkiszak, Janusz; McGuire, Valerie; McCauley, Bryan M; Mack, Marie; Lubiński, Jan; Longacre, Teri A; Li, Zheng; Lester, Jenny; Kennedy, Catherine J; Kalli, Kimberly R; Jung, Audrey Y; Johnatty, Sharon E; Jimenez-Linan, Mercedes; Jensen, Allan; Intermaggio, Maria P; Hung, Jillian; Herpel, Esther; Hernandez, Brenda Y; Hartkopf, Andreas D; Harnett, Paul R; Ghatage, Prafull; García-Bueno, José M; Gao, Bo; Fereday, Sian; Eilber, Ursula; Edwards, Robert P; de Sousa, Christiani B; de Andrade, Jurandyr M; Chudecka-Głaz, Anita; Chenevix-Trench, Georgia; Cazorla, Alicia; Brucker, Sara Y; Alsop, Jennifer; Whittemore, Alice S; Steed, Helen; Staebler, Annette; Moysich, Kirsten B; Menon, Usha; Koziak, Jennifer M; Kommoss, Stefan; Kjaer, Susanne K; Kelemen, Linda E; Karlan, Beth Y; Huntsman, David G; Høgdall, Estrid; Gronwald, Jacek; Goodman, Marc T; Gilks, Blake; García, María José; Fasching, Peter A; de Fazio, Anna; Deen, Suha; Chang-Claude, Jenny; Candido Dos Reis, Francisco J; Campbell, Ian G; Brenton, James D; Bowtell, David D; Benítez, Javier; Pharoah, Paul D P; Köbel, Martin; Ramus, Susan J; Goode, Ellen L

    2018-03-01

    To evaluate myeloid differentiation primary response gene 88 (MyD88) and Toll-like receptor 4 (TLR4) expression in relation to clinical features of epithelial ovarian cancer, histologic subtypes, and overall survival. We conducted centralized immunohistochemical staining, semi-quantitative scoring, and survival analysis in 5263 patients participating in the Ovarian Tumor Tissue Analysis consortium. Patients were diagnosed between January 1, 1978, and December 31, 2014, including 2865 high-grade serous ovarian carcinomas (HGSOCs), with more than 12,000 person-years of follow-up time. Tissue microarrays were stained for MyD88 and TLR4, and staining intensity was classified using a 2-tiered system for each marker (weak vs strong). Expression of MyD88 and TLR4 was similar in all histotypes except clear cell ovarian cancer, which showed reduced expression compared with other histotypes (P<.001 for both). In HGSOC, strong MyD88 expression was modestly associated with shortened overall survival (hazard ratio [HR], 1.13; 95% CI, 1.01-1.26; P=.04) but was also associated with advanced stage (P<.001). The expression of TLR4 was not associated with survival. In low-grade serous ovarian cancer (LGSOC), strong expression of both MyD88 and TLR4 was associated with favorable survival (HR [95% CI], 0.49 [0.29-0.84] and 0.44 [0.21-0.89], respectively; P=.009 and P=.02, respectively). Results are consistent with an association between strong MyD88 staining and advanced stage and poorer survival in HGSOC and demonstrate correlation between strong MyD88 and TLR4 staining and improved survival in LGSOC, highlighting the biological differences between the 2 serous histotypes. Copyright © 2017 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  11. Transcatheter pledget-assisted suture tricuspid annuloplasty (PASTA) to create a double-orifice valve.

    PubMed

    Khan, Jaffar M; Rogers, Toby; Schenke, William H; Greenbaum, Adam B; Babaliaros, Vasilis C; Paone, Gaetano; Ramasawmy, Rajiv; Chen, Marcus Y; Herzka, Daniel A; Lederman, Robert J

    2018-02-06

    Pledget-assisted suture tricuspid valve annuloplasty (PASTA) is a novel technique using marketed equipment to deliver percutaneous trans-annular sutures to create a double-orifice tricuspid valve. Tricuspid regurgitation is a malignant disease with high surgical mortality and no commercially available transcatheter solution in the US. Two iterations of PASTA were tested using trans-apical or trans-jugular access in swine. Catheters directed paired coronary guidewires to septal and lateral targets on the tricuspid annulus under fluoroscopic and echocardiographic guidance. Guidewires were electrified to traverse the annular targets and exchanged for pledgeted sutures. The sutures were drawn together and knotted, apposing septal and lateral targets, creating a double orifice tricuspid valve. Twenty-two pigs underwent PASTA. Annular and chamber dimensions were reduced (annular area, 10.1 ± 0.8 cm 2 to 3.8 ± 1.5 cm 2 (naïve) and 13.1 ± 1.5 cm 2 to 6.2 ± 1.0 cm 2 (diseased); septal-lateral diameter, 3.9 ± 0.3 mm to 1.4 ± 0.6 mm (naïve) and 4.4 ± 0.4 mm to 1.7 ± 1.0 mm (diseased); and right ventricular end-diastolic volume, 94 ± 13 ml to 85 ± 14 ml (naïve) and 157 ± 25 ml to 143 ± 20 ml (diseased)). MRI derived tricuspid regurgitation fraction fell from 32 ± 12% to 4 ± 5%. Results were sustained at 30 days. Pledget pull-through force was five-fold higher (40.6 ± 11.7N vs 8.0 ± 2.6N, P < .01) using this strategy compared to single puncture techniques used to anchor current investigational devices. Serious complications were related to apical access. PASTA reduces annular dimensions and tricuspid regurgitation in pigs. It may be cautiously applied to selected patients with severe tricuspid regurgitation and no options. This is the first transcatheter procedure, to our knowledge, to deliver standard pledgeted sutures to repair cardiac pathology. Published 2018. This article is a U

  12. Cardiovascular anatomy in children with bidirectional Glenn anastomosis, regarding the transcatheter Fontan completion.

    PubMed

    Sizarov, Aleksander; Raimondi, Francesca; Bonnet, Damien; Boudjemline, Younes

    2018-04-01

    Transcatheter stent-secured completion of total cavopulmonary connection (TCPC) after surgical preparations during the Glenn anastomosis procedure has been reported, but complications from this approach have precluded its clinical acceptance. To analyse cardiovascular morphology and dimensions in children with bidirectional Glenn anastomosis, regarding the optimal device design for transcatheter Fontan completion without special surgical "preconditionings". We retrospectively analysed 60 thoracic computed tomography and magnetic resonance angiograms performed in patients with a median age of 4.1 years (range: 1.8-17.1 years). Additionally, we simulated TCPC completion using different intra-atrial stent-grafts in a three-dimensional model of the representative anatomy, and performed calculations to determine the optimal stent-graft dimensions, using measured distances. Two types of cardiovascular arrangement were identified: left atrium interposing between the right pulmonary artery (RPA) and inferior vena cava, with the right upper pulmonary vein (RUPV) orifice close to the intercaval axis (65%); and intercaval axis traversing only the right(-sided) atrial cavity, with the RUPV located posterior to the atrial wall (35%). In the total population, the shortest median RPA-to-atrial wall distance was 1.9mm (range: 0.6-13.8mm), while the mean intra-atrial distance along the intercaval axis was 50.1±11.2mm. Regardless of the arrangement, 83% of all patients required a deviation of at least 5.9±2.4mm (range: 1.2-12.7mm) of the stent-graft centre at the RUPV level anteriorly to the intercaval axis to avoid covering or compressing this vein. Fixing the anterior deviation of the curved stent-graft centre at 10mm significantly decreased the range of bend angle per every given RUPV-RPA distance. For both types of cardiovascular arrangement, after conventional bidirectional Glenn anastomosis, the intra-atrial curved stent-graft seemed most suitable for achieving

  13. Impact of Transcatheter Technology on Surgical Aortic Valve Replacement Volume, Outcomes, and Cost.

    PubMed

    Hawkins, Robert B; Downs, Emily A; Johnston, Lily E; Mehaffey, J Hunter; Fonner, Clifford E; Ghanta, Ravi K; Speir, Alan M; Rich, Jeffrey B; Quader, Mohammed A; Yarboro, Leora T; Ailawadi, Gorav

    2017-06-01

    Transcatheter aortic valve replacement (TAVR) represents a disruptive technology that is rapidly expanding in use. We evaluated the effect on surgical aortic valve replacement (SAVR) patient selection, outcomes, volume, and cost. A total of 11,565 patients who underwent SAVR, with or without coronary artery bypass grafting (2002 to 2015), were evaluated from the Virginia Cardiac Services Quality Initiative database. Patients were stratified by surgical era: pre-TAVR era (2002 to 2008, n = 5,113), early-TAVR era (2009 to 2011, n = 2,709), and commercial-TAVR era (2012 to 2015, n = 3,743). Patient characteristics, outcomes, and resource utilization were analyzed by univariate analyses. Throughout the study period, statewide SAVR volumes increased with median volumes of pre-TAVR: 722 cases/year, early-TAVR: 892 cases/year, and commercial-TAVR: 940 cases/year (p = 0.005). Implementation of TAVR was associated with declining Society of Thoracic Surgeons predicted risk of mortality among SAVR patients (3.7%, 2.6%, and 2.4%; p < 0.0001), despite increasing rates of comorbid disease. The mortality rate was lowest in the current commercial-TAVR era (3.9%, 4.3%, and 3.2%; p = 0.05), and major morbidity decreased throughout the time period (21.2%, 20.5%, and 15.2%; p < 0.0001). The lowest observed-to-expected ratios for both occurred in the commercial-TAVR era (0.9 and 0.9, respectively). Resource utilization increased generally, including total cost increases from $42,835 to $51,923 to $54,710 (p < 0.0001). At present, SAVR volumes have not been affected by the introduction of TAVR. The outcomes for SAVR continue to improve, potentially due to availability of transcatheter options for high-risk patients. Despite rising costs for SAVR, open approaches still provide a significant cost advantage over TAVR. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Framework for quantitative evaluation of 3D vessel segmentation approaches using vascular phantoms in conjunction with 3D landmark localization and registration

    NASA Astrophysics Data System (ADS)

    Wörz, Stefan; Hoegen, Philipp; Liao, Wei; Müller-Eschner, Matthias; Kauczor, Hans-Ulrich; von Tengg-Kobligk, Hendrik; Rohr, Karl

    2016-03-01

    We introduce a framework for quantitative evaluation of 3D vessel segmentation approaches using vascular phantoms. Phantoms are designed using a CAD system and created with a 3D printer, and comprise realistic shapes including branches and pathologies such as abdominal aortic aneurysms (AAA). To transfer ground truth information to the 3D image coordinate system, we use a landmark-based registration scheme utilizing fiducial markers integrated in the phantom design. For accurate 3D localization of the markers we developed a novel 3D parametric intensity model that is directly fitted to the markers in the images. We also performed a quantitative evaluation of different vessel segmentation approaches for a phantom of an AAA.

  15. Incidence, Timing, and Predictors of Valve Hemodynamic Deterioration After Transcatheter Aortic Valve Replacement: Multicenter Registry.

    PubMed

    Del Trigo, Maria; Muñoz-Garcia, Antonio J; Wijeysundera, Harindra C; Nombela-Franco, Luis; Cheema, Asim N; Gutierrez, Enrique; Serra, Vicenç; Kefer, Joelle; Amat-Santos, Ignacio J; Benitez, Luis M; Mewa, Jumana; Jiménez-Quevedo, Pilar; Alnasser, Sami; Garcia Del Blanco, Bruno; Dager, Antonio; Abdul-Jawad Altisent, Omar; Puri, Rishi; Campelo-Parada, Francisco; Dahou, Abdellaziz; Paradis, Jean-Michel; Dumont, Eric; Pibarot, Philippe; Rodés-Cabau, Josep

    2016-02-16

    Scarce data exist on the incidence of and factors associated with valve hemodynamic deterioration (VHD) after transcatheter aortic valve replacement (TAVR). This study sought to determine the incidence, timing, and predictors of VHD in a large cohort of patients undergoing TAVR. This multicenter registry included 1,521 patients (48% male; 80 ± 7 years of age) who underwent TAVR. Mean echocardiographic follow-up was 20 ± 13 months (minimum: 6 months). Echocardiographic examinations were performed at discharge, at 6 to 12 months, and yearly thereafter. Annualized changes in mean gradient (mm Hg/year) were calculated by dividing the difference between the mean gradient at last follow-up and the gradient at discharge by the time between examinations. VHD was defined as a ≥10 mm Hg increase in transprosthetic mean gradient during follow-up compared with discharge assessment. The overall mean annualized rate of transprosthetic gradient progression during follow-up was 0.30 ± 4.99 mm Hg/year. A total of 68 patients met criteria of VHD (incidence: 4.5% during follow-up). The absence of anticoagulation therapy at hospital discharge (p = 0.002), a valve-in-valve (TAVR in a surgical valve) procedure (p = 0.032), the use of a 23-mm valve (p = 0.016), and a greater body mass index (p = 0.001) were independent predictors of VHD. There was a mild but significant increase in transvalvular gradients over time after TAVR. The lack of anticoagulation therapy, a valve-in-valve procedure, a greater body mass index, and the use of a 23-mm transcatheter valve were associated with higher rates of VHD post-TAVR. Further prospective studies are required to determine whether a specific antithrombotic therapy post-TAVR may reduce the risk of VHD. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  16. In-Graft Endovascular Stenting Repair for Supravalvular Stenosis From Aortic Rupture After Balloon-Expanding Transcatheter Aortic Valve Implantation.

    PubMed

    Furukawa, Nobuyuki; Scholtz, Werner; Haas, Nikolaus; Ensminger, Stephan; Gummert, Jan; Börgermann, Jochen

    2015-01-01

    An 81-year-old man with high-grade aortic valve stenosis and status post-coronary artery bypass grafting and supracoronary replacement of the ascending aorta was referred for transcatheter aortic valve implantation. He was in New York Heart Association class III and had dyspnea. After appropriate screening, we implanted a 29-mm SAPIEN XT valve (Edwards Lifesciences, Irvine, CA USA) through a transapical approach because of severe peripheral arterial occlusive disease. Postinterventional aortography revealed correct positioning and function of the valve and free coronary ostia but contrast extravasation in the vicinity of the interposed vascular prosthesis, resulting in severe luminal narrowing. We chose to manage the stenosis with an endovascular stent. After stenting, extravascular compression was markedly reduced, and the pressure gradient disappeared. The patient was discharged home on the 20th postoperative day. Three months later, computed tomography depicted correct positioning of both grafts. The patient's general health is good, and he is now in New York Heart Association class II. This case illustrates a complication of transcatheter aortic valve implantation specific for patients with an ascending aortic graft. Although stenting may be a good solution, as depicted by this case, self-expanding transcatheter aortic valves should be preferred in patients with ascending aortic grafts to avoid the described complication.

  17. Transcatheter closure of Patent Ductus Arteriosus through only venous route.

    PubMed

    Sheikh, Abdul Malik; Duke, Abdul Karim; Sattar, Hina

    2018-03-01

    Patent ductus arteriosus is a common congenital cardiac defect comprising 5-10% of all these defects in term neonates. Although open chest and video-assisted interruption are still in use, transcatheter occlusion has rapidly become the first choice for patent ductus arteriosus closure in the appropriate patient. Percutaneous closure of patent ductus arteriosus is widely done by transvenous approach guided by aortic access. We present the case of a 2 year old girl who underwent patent ductus arteriosus device occlusion with transvenous access only.

  18. Nanoscale Structure of Type I Collagen Fibrils: Quantitative Measurement of D-spacing

    PubMed Central

    Erickson, Blake; Fang, Ming; Wallace, Joseph M.; Orr, Bradford G.; Les, Clifford M.; Holl, Mark M. Banaszak

    2012-01-01

    This paper details a quantitative method to measure the D-periodic spacing of Type I collagen fibrils using Atomic Force Microscopy coupled with analysis using a 2D Fast Fourier Transform approach. Instrument calibration, data sampling and data analysis are all discussed and comparisons of the data to the complementary methods of electron microscopy and X-ray scattering are made. Examples of the application of this new approach to the analysis of Type I collagen morphology in disease models of estrogen depletion and Osteogenesis Imperfecta are provided. We demonstrate that it is the D-spacing distribution, not the D-spacing mean, that showed statistically significant differences in estrogen depletion associated with early stage Osteoporosis and Osteogenesis Imperfecta. The ability to quantitatively characterize nanoscale morphological features of Type I collagen fibrils will provide important structural information regarding Type I collagen in many research areas, including tissue aging and disease, tissue engineering, and gene knock out studies. Furthermore, we also envision potential clinical applications including evaluation of tissue collagen integrity under the impact of diseases or drug treatments. PMID:23027700

  19. Procedural Experience for Transcatheter Aortic Valve Replacement and Relation to Outcomes: The STS/ACC TVT Registry.

    PubMed

    Carroll, John D; Vemulapalli, Sreekanth; Dai, Dadi; Matsouaka, Roland; Blackstone, Eugene; Edwards, Fred; Masoudi, Frederick A; Mack, Michael; Peterson, Eric D; Holmes, David; Rumsfeld, John S; Tuzcu, E Murat; Grover, Frederick

    2017-07-04

    Transcatheter aortic valve replacement (TAVR) has been introduced into U.S. clinical practice with efforts to optimize outcomes and minimize the learning curve. The goal of this study was to assess the degree to which increasing experience during the introduction of this procedure, separated from other outcome determinants including patient and procedural characteristics, is associated with outcomes. The authors evaluated the association of hospital TAVR volume and patient outcomes for TAVR by using data from 42,988 commercial procedures conducted at 395 hospitals submitting to the Transcatheter Valve Therapy Registry from 2011 through 2015. Outcomes assessed included adjusted and unadjusted in-hospital major adverse events. Increasing site volume was associated with lower in-hospital risk-adjusted outcomes, including mortality (p < 0.02), vascular complications (p < 0.003), and bleeding (p < 0.001) but was not associated with stroke (p = 0.14). From the first case to the 400th case in the volume-outcome model, risk-adjusted adverse outcomes declined, including mortality (3.57% to 2.15%), bleeding (9.56% to 5.08%), vascular complications (6.11% to 4.20%), and stroke (2.03% to 1.66%). Vascular and bleeding volume-outcome associations were nonlinear with a higher risk of adverse outcomes in the first 100 cases. An association of procedure volume with risk-adjusted outcomes was also seen in the subgroup having transfemoral access. The initial adoption of TAVR into practice in the United States showed that increasing experience was associated with better outcomes. This association, whether deemed a prolonged learning curve or a manifestation of a volume-outcome relationship, suggested that concentrating experience in higher volume heart valve centers might be a means of improving outcomes. (STS/ACC Transcatheter Valve Therapy Registry [TVT Registry]; NCT01737528). Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All

  20. Synthesis of 7-(2,4-dichlorophenyl)-D-erythro-3-hydroxy-5-heptanolide, 6-(2,4-dichlorophenyl)-D-erythro-2,4-dihydroxyhexane-1-sulfonic acid, and 6-(2,4-dichlorophenyl)-D-erythro-2,4-dihydroxyhexylphosphonic acid.

    PubMed

    Hodosi, G; Galambos, G; Podányi, B; Kuszmann, J

    1992-03-02

    6-(2,4-Dichlorophenyl)-D-erythro-1,2,4-hexanetriol, synthesised from D-glucose, was partially silylated, then reacted with 2-methoxypropene to afford 1-O-tert-butyldimethylsilyl-6-(2,4- dichlorophenyl)-2,4-O-isopropylidene-D-erythro-1,2,4-hexanetriol (17). Desilylation of 17 gave 6-(2,4-dichlorophenyl)-2,4-O-isopropylidene-D- erythro-1,2,4-hexanetriol, which was converted into the 1-tosylate 18 and the 1-bromo derivative 19. Reaction of 18 with potassium thiolbenzoate gave, after debenzoylation, oxidation, and deprotection, 6-(2,4-dichlorophenyl)-D-erythro-2,4-dihydroxyhexane-1-sulfonic acid (4). Reaction of 18 or 19 with triethyl phosphite gave, after deprotection, 6-(2,4-dichlorophenyl)-D-erythro-2,4-dihydroxyhexyl-phosphonic acid (5), and reaction of 19 with potassium cyanide gave, after subsequent hydrolysis and deprotection, 7-(2,4-dichlorophenyl)-D-erythro-3-hydroxy-5-heptanolide (3).

  1. Atrioventricular and intraventricular block after transcatheter aortic valve implantation.

    PubMed

    Lee, Jane J; Goldschlager, Nora; Mahadevan, Vaikom S

    2018-06-24

    Aortic stenosis is the most common valvular heart disease in industrialized countries and the most common cause of left ventricular outflow tract (LVOT) obstruction. Transcatheter aortic valve replacement (TAVR) is an alternative to surgical aortic valve replacement for intermediate to high-risk surgical candidates with symptomatic severe aortic stenosis. Conduction system abnormalities, including atrioventricular (AV) and intraventricular (IV) block, are the most common complication of TAVR. In this review, we aim to explore the anatomical issues relevant to atrioventricular block, the relevant clinical and procedural aspects, and the management and long-term implications of AV and IV block.

  2. WE-H-207A-02: Attenuation Correction in 4D-PET Using a Single-Phase Attenuation Map

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalantari, F; Wang, J

    2016-06-15

    Purpose: 4D-PET imaging has been proposed as a potential solution to the respiratory motion effect in thoracic region. CT-based attenuation correction (AC) is an essential step toward quantitative imaging for PET. However, due to the temporal difference of 4D-PET and a single breath-hold CT, motion artifacts are observed in the attenuation-corrected PET images that can lead to error in tumor shape and uptake. We introduce a practical method for aligning single-phase CT to all other 4D-PET phases using a penalized non-rigid demons registration. Methods: Individual 4D-PET frames were reconstructed without AC. Non-rigid Demons registration was used to derive deformation vectormore » fields (DVFs) between the PET matched with CT phase and other 4D-PET images. While attenuated PET images provide enough useful data for organ borders such as lung and liver, tumors are not distinguishable from background due to loss of contrast. To preserve tumor shape in different phases, from CT image an ROI covering tumor was excluded from non-rigid transformation. Mean DVF of the central region of the tumor was assigned to all voxels in the ROI. This process mimics a rigid transformation of tumor along with a non-rigid transformation of other organs. 4D XCAT phantom with spherical tumors in lung with diameters ranging from 10 to 40 mm was used to evaluate the algorithm. Results: Motion related induced artifacts in attenuation-corrected 4D-PET images were significantly reduced. For tumors smaller than 20 mm, non-rigid transformation was capable to provide quantitative results. However, for larger tumors, where tumor self-attenuation is considerable, our combined method yields superior results. Conclusion: We introduced a practical method for deforming a single CT to match all 4D-PET images for accurate AC. Although 4D-PET data include insignificant anatomical information, we showed that they are still useful to estimate DVFs for aligning attenuation map and accurate AC.« less

  3. Current transcatheter devices to treat functional tricuspid regurgitation with discussion of issues relevant to clinical trial design

    PubMed Central

    2017-01-01

    Functional or secondary tricuspid regurgitation (TR) has seen increased attention in recent times as relationships with clinically-relevant outcomes have come to light. Despite the association of increased mortality with significant TR, the disease remains under-recognized and thus relatively untreated. In addition, the disease itself has not been extensively studied and the interactions between annular dilatation, right heart disease and pulmonary hypertension are poorly understood. However, the high mortality and recurrence rate with current surgical replacement or repair techniques is well recognised, opening the door to transcatheter therapies for functional TR. The current perspective reviews the rationale for transcatheter solutions, describes some of the current approaches and discusses the ongoing questions of a poorly-studied condition which may limit the design of clinical trials for this disease. PMID:28706866

  4. 4D atlas of the mouse embryo for precise morphological staging.

    PubMed

    Wong, Michael D; van Eede, Matthijs C; Spring, Shoshana; Jevtic, Stefan; Boughner, Julia C; Lerch, Jason P; Henkelman, R Mark

    2015-10-15

    After more than a century of research, the mouse remains the gold-standard model system, for it recapitulates human development and disease and is quickly and highly tractable to genetic manipulations. Fundamental to the power and success of using a mouse model is the ability to stage embryonic mouse development accurately. Past staging systems were limited by the technologies of the day, such that only surface features, visible with a light microscope, could be recognized and used to define stages. With the advent of high-throughput 3D imaging tools that capture embryo morphology in microscopic detail, we now present the first 4D atlas staging system for mouse embryonic development using optical projection tomography and image registration methods. By tracking 3D trajectories of every anatomical point in the mouse embryo from E11.5 to E14.0, we established the first 4D atlas compiled from ex vivo 3D mouse embryo reference images. The resulting 4D atlas comprises 51 interpolated 3D images in this gestational range, resulting in a temporal resolution of 72 min. From this 4D atlas, any mouse embryo image can be subsequently compared and staged at the global, voxel and/or structural level. Assigning an embryonic stage to each point in anatomy allows for unprecedented quantitative analysis of developmental asynchrony among different anatomical structures in the same mouse embryo. This comprehensive developmental data set offers developmental biologists a new, powerful staging system that can identify and compare differences in developmental timing in wild-type embryos and shows promise for localizing deviations in mutant development. © 2015. Published by The Company of Biologists Ltd.

  5. Wall-crossing in coupled 2d-4d systems

    NASA Astrophysics Data System (ADS)

    Gaiotto, Davide; Moore, Gregory W.; Neitzke, Andrew

    2012-12-01

    We introduce a new wall-crossing formula which combines and generalizes the Cecotti-Vafa and Kontsevich-Soibelman formulas for supersymmetric 2d and 4d systems respectively. This 2d-4d wall-crossing formula governs the wall-crossing of BPS states in an {N}=2 supersymmetric 4d gauge theory coupled to a supersymmetric surface defect. When the theory and defect are compactified on a circle, we get a 3d theory with a supersymmetric line operator, corresponding to a hyperholomorphic connection on a vector bundle over a hyperkähler space. The 2d-4d wall-crossing formula can be interpreted as a smoothness condition for this hyperholomorphic connection. We explain how the 2d-4d BPS spectrum can be determined for 4d theories of class {S} , that is, for those theories obtained by compactifying the six-dimensional (0, 2) theory with a partial topological twist on a punctured Riemann surface C. For such theories there are canonical surface defects. We illustrate with several examples in the case of A 1 theories of class {S} . Finally, we indicate how our results can be used to produce solutions to the A 1 Hitchin equations on the Riemann surface C.

  6. Initial German experience with transapical implantation of a second-generation transcatheter heart valve for the treatment of aortic regurgitation.

    PubMed

    Seiffert, Moritz; Bader, Ralf; Kappert, Utz; Rastan, Ardawan; Krapf, Stephan; Bleiziffer, Sabine; Hofmann, Steffen; Arnold, Martin; Kallenbach, Klaus; Conradi, Lenard; Schlingloff, Friederike; Wilbring, Manuel; Schäfer, Ulrich; Diemert, Patrick; Treede, Hendrik

    2014-10-01

    This analysis reports on the initial German multicenter experience with the JenaValve (JenaValve Technology GmbH, Munich, Germany) transcatheter heart valve for the treatment of pure aortic regurgitation. Experience with transcatheter aortic valve implantation (TAVI) for severe aortic regurgitation is limited due to the risk of insufficient anchoring of the valve stent within the noncalcified aortic annulus. Transapical TAVI with a JenaValve for the treatment of severe aortic regurgitation was performed in 31 patients (age 73.8 ± 9.1 years) in 9 German centers. All patients were considered high risk for surgery (logistic EuroSCORE [European System for Cardiac Operative Risk Evaluation] 23.6 ± 14.5%) according to a local heart team consensus. Procedural results and clinical outcomes up to 6 months were analyzed. Implantation was successful in 30 of 31 cases (aortic annulus diameter 24.7 ± 1.5 mm); transcatheter heart valve dislodgement necessitated valve-in-valve implantation in 1 patient. Post-procedural aortic regurgitation was none/trace in 28 of 31 and mild in 3 of 31 patients. During follow-up, 2 patients underwent valvular reinterventions (surgical aortic valve replacement for endocarditis, valve-in-valve implantation for increasing paravalvular regurgitation). All-cause mortality was 12.9% and 19.3% at 30 days and 6 months, respectively. In the remaining patients, a significant improvement in New York Heart Association class was observed and persisted up to 6 months after TAVI. Aortic regurgitation remains a challenging pathology for TAVI. After initial demonstration of feasibility, this multicenter study revealed the JenaValve transcatheter heart valve as a reasonable option in this subset of patients. However, a significant early noncardiac mortality related to the high-risk population emphasizes the need for careful patient selection. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  7. Vancouver Transcatheter Aortic Valve Replacement Clinical Pathway: Minimalist Approach, Standardized Care, and Discharge Criteria to Reduce Length of Stay.

    PubMed

    Lauck, Sandra B; Wood, David A; Baumbusch, Jennifer; Kwon, Jae-Yung; Stub, Dion; Achtem, Leslie; Blanke, Philipp; Boone, Robert H; Cheung, Anson; Dvir, Danny; Gibson, Jennifer A; Lee, Bobby; Leipsic, Jonathan; Moss, Robert; Perlman, Gidon; Polderman, Jopie; Ramanathan, Krishnan; Ye, Jian; Webb, John G

    2016-05-01

    We describe the development, implementation, and evaluation of a standardized clinical pathway to facilitate safe discharge home at the earliest time after transfemoral transcatheter aortic valve replacement. Between May 2012 and October 2014, the Heart Team developed a clinical pathway suited to the unique requirements of transfemoral transcatheter aortic valve replacement in contemporary practice. The components included risk-stratified minimalist periprocedure approach, standardized postprocedure care with early mobilization and reconditioning, and criteria-driven discharge home. Our aim was to reduce variation in care, identify a subgroup of patients suitable for early discharge (≤48 hours), and decrease length of stay for all patients. We addressed barriers related to historical practices, complex multidisciplinary stakeholder engagement, and adoption of length of stay as a quality indicator. We retrospectively reviewed the experiences of 393 consecutive patients; 150 (38.2%) were discharged early. At baseline, early discharge patients had experienced less previous balloon aortic valvuloplasty, had higher left ventricular ejection fraction, better cognitive function, and were less frail than the standard discharge group (>48 hours). Early discharge was associated with the use of local anesthesia, implantation of balloon expandable device, avoidance of urinary catheter, and early removal of temporary pacemaker. Median length of stay was 1 day for early discharge and 3 days for other patients; 97.7% were discharged home. There were no differences in 30-day mortality (1.3%), disabling stroke (0.8%), or readmission (10.7%). The implementation of a transcatheter aortic valve replacement clinical pathway shifted the program's approach to combine standardized processes and individual risk stratification. The Vancouver transcatheter aortic valve replacement clinical pathway requires a rigorous assessment to determine its efficacy, safety, and reproducibility.

  8. Comparison of PIV with 4D-Flow in a physiological accurate flow phantom

    NASA Astrophysics Data System (ADS)

    Sansom, Kurt; Balu, Niranjan; Liu, Haining; Aliseda, Alberto; Yuan, Chun; Canton, Maria De Gador

    2016-11-01

    Validation of 4D MRI flow sequences with planar particle image velocimetry (PIV) is performed in a physiologically-accurate flow phantom. A patient-specific phantom of a carotid artery is connected to a pulsatile flow loop to simulate the 3D unsteady flow in the cardiovascular anatomy. Cardiac-cycle synchronized MRI provides time-resolved 3D blood velocity measurements in clinical tool that is promising but lacks a robust validation framework. PIV at three different Reynolds numbers (540, 680, and 815, chosen based on +/- 20 % of the average velocity from the patient-specific CCA waveform) and four different Womersley numbers (3.30, 3.68, 4.03, and 4.35, chosen to reflect a physiological range of heart rates) are compared to 4D-MRI measurements. An accuracy assessment of raw velocity measurements and a comparison of estimated and measureable flow parameters such as wall shear stress, fluctuating velocity rms, and Lagrangian particle residence time, will be presented, with justification for their biomechanics relevance to the pathophysiology of arterial disease: atherosclerosis and intimal hyperplasia. Lastly, the framework is applied to a new 4D-Flow MRI sequence and post processing techniques to provide a quantitative assessment with the benchmarked data. Department of Education GAANN Fellowship.

  9. [Selection of patients for transcatheter aortic valve implantation].

    PubMed

    Tron, Christophe; Godin, Matthieu; Litzler, Pierre-Yves; Bauer, Fabrice; Caudron, Jérome; Dacher, Jean-Nicolas; Borz, Bogdan; Canville, Alexandre; Kurtz, Baptiste; Bessou, Jean-Paul; Cribier, Alain; Eltchaninoff, Hélène

    2012-06-01

    A good selection of patients is a crucial step before transcatheter aortic valve implantation (TAVI) in order to select the good indications and choose the access route. TAVI should be considered only in patients with symptomatic severe aortic stenosis and either contraindication or high surgical risk. Indication for TAVI should be discussed in a multidisciplinary team meeting. Echocardiography and/or CT scan are mandatory to evaluate the aortic annulus size and select the good prosthesis size. The possibility of transfemoral implantation is evaluated by angiography and CT scan, and based on the arterial diameters, but also on the presence of tortuosities and arterial calcifications. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  10. Minimally Invasive Aortic Valve Replacement Following Root Enlargement on too Narrow Annulus to Perform Transcatheter Aortic Valve Implantation.

    PubMed

    Sakamoto, Kosuke; Totsugawa, Toshinori; Hiraoka, Arudo; Tamura, Kentaro; Yoshitaka, Hidenori; Sakaguchi, Taichi

    2018-05-30

    An 88-year-old woman was diagnosed with aortic stenosis and an aortic annulus that was too narrow to perform transcatheter aortic valve implantation. Surgery was performed through a 7-cm right mini-thoracotomy at the fourth intercostal space. A 19-mm aortic valve bioprosthesis was implanted after root enlargement. The fourth intercostal space was a suitable site for aortic root enlargement because of the shorter skin-to-root distance and the detailed exposure of the aortic valve after cutting the aortic wall. This study concluded that minimally-invasive aortic valve replacement following root enlargement can be an option for the treatment of elderly patients with aortic stenosis accompanied by an annulus that is too small to perform transcatheter aortic valve implantation.

  11. Goose-neck snare-assisted transcatheter ASD closure: A safety procedure for large and complex ASDs.

    PubMed

    Butera, Gianfranco; Lovin, Nicusor; Basile, Domenica Paola; Carminati, Mario

    2016-04-01

    To report on a new technique that increases the safety of percutaneous atrial septal defect (ASD) closure using a goose-neck snare system. ASD transcatheter closure is a widespread procedure. However, in some cases, ASDs may be large and with soft rims. In these situation, a potential risk exists for device malposition or embolization. When transesophageal echocardiography (TEE) evaluation and balloon sizing showed large defects with floppy rims the chosen Amplatzer device was implanted in a standard way. In large defects with floppy rims, before release a 5-mm goose-neck snare with its 4 Fr catheter was placed across the delivery cable and fixed to catch the screwing mechanism of implanted Amplatzer device. The delivery cable was unscrewed and the device reached its final position without any tension. If the position was considered satisfactory the device was released from the goose-neck snare. Thirteen patients had a snare-assisted ASD transcatheter closure. Median device size was 24 mm (range 14-38 mm). Retrieval or repositioning of the device using the goose-neck snare was performed in four cases: in three patients, because of device malposition after delivery cable release and in one patient, because of unsuitability of closure of a second significant defect. Furthermore, in two subjects with multiple ASDs, a second fenestration looked quite significant with the device still attached to the delivery cable while it appeared smaller after release. Snare-assisted Amplatzer ASD device placement is a new method for ASD percutaneous closure and adds safety to the procedure. © 2016 Wiley Periodicals, Inc.

  12. Quantitative two-dimensional ultrashort echo time magnetization transfer (2D UTE-MT) imaging of cortical bone.

    PubMed

    Ma, Ya-Jun; Tadros, Anthony; Du, Jiang; Chang, Eric Y

    2018-04-01

    To investigate quantitative 2D ultrashort echo time magnetization transfer (UTE-MT) imaging in ex vivo bovine cortical bone and in vivo human tibial cortical bone. Data were acquired from five fresh bovine cortical bone samples and five healthy volunteer tibial cortical bones using a 2D UTE-MT sequence on a clinical 3T scanner. The 2D UTE-MT sequence used four or five MT powers with five frequency offsets. Results were analyzed with a two-pool quantitative MT model, providing measurements of macromolecular fraction (f), macromolecular proton transverse relaxation times (T 2m ), proton exchange rates from water/macromolecular to the macromolecular/water pool (RM 0m /RM 0w ), and spin-lattice relaxation rate of water pool (R 1w ). A sequential air-drying study for a small bovine cortical bone chip was used to investigate whether above MT modeling parameters were sensitive to the water loss. Mean fresh bovine cortical bone values for f, T 2m , R 1w , RM 0m , and RM 0w were 59.9 ± 7.3%, 14.6 ± 0.3 μs, 9.9 ± 2.4 s -1 , 17.9 ± 3.6 s -1 , and 11.8 ± 2.0 s -1 , respectively. Mean in vivo human cortical bone values for f, T 2m , R 1w , RM 0m and RM 0w were 54.5 ± 4.9%, 15.4 ± 0.6 μs, 8.9 ± 1.1 s -1 , 11.5 ± 3.5 s -1 , and 9.5 ± 1.9 s -1 , respectively. The sequential air-drying study shows that f, RM 0m , and R 1w were increased with longer drying time. UTE-MT two-pool modeling provides novel and useful quantitative information for cortical bone. Magn Reson Med 79:1941-1949, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  13. Tissue-Engineered Heart Valve with a Tubular Leaflet Design for Minimally Invasive Transcatheter Implantation

    PubMed Central

    Moreira, Ricardo; Velz, Thaddaeus; Alves, Nuno; Gesche, Valentine N.; Malischewski, Axel; Schmitz-Rode, Thomas; Frese, Julia

    2015-01-01

    Transcatheter aortic valve implantation of (nonviable) bioprosthetic valves has been proven a valid alternative to conventional surgical implantation in patients at high or prohibitive mortality risk. In this study we present the in vitro proof-of-principle of a newly developed tissue-engineered heart valve for minimally invasive implantation, with the ultimate aim of adding the unique advantages of a living tissue with regeneration capabilities to the continuously developing transcatheter technologies. The tube-in-stent is a fibrin-based tissue-engineered valve with a tubular leaflet design. It consists of a tubular construct sewn into a self-expandable nitinol stent at three commissural attachment points and along a circumferential line so that it forms three coaptating leaflets by collapsing under diastolic back pressure. The tubular constructs were molded with fibrin and human umbilical vein cells. After 3 weeks of conditioning in a bioreactor, the valves were fully functional with unobstructed opening (systolic phase) and complete closure (diastolic phase). Tissue analysis showed a homogeneous cell distribution throughout the valve's thickness and deposition of collagen types I and III oriented along the longitudinal direction. Immunohistochemical staining against CD31 and scanning electron microscopy revealed a confluent endothelial cell layer on the surface of the valves. After harvesting, the valves underwent crimping for 20 min to simulate the catheter-based delivery. This procedure did not affect the valvular functionality in terms of orifice area during systole and complete closure during diastole. No influence on the extracellular matrix organization, as assessed by immunohistochemistry, nor on the mechanical properties was observed. These results show the potential of combining tissue engineering and minimally invasive implantation technology to obtain a living heart valve with a simple and robust tubular design for transcatheter delivery. The effect

  14. Manifestation of intra-atomic 5d6s-4f exchange coupling in photoexcited gadolinium

    NASA Astrophysics Data System (ADS)

    Zhang, G. P.; Jenkins, T.; Bennett, M.; Bai, Y. H.

    2017-12-01

    Intra-atomic exchange couplings (IECs) between 5d6s and 4f electrons are ubiquitous in rare-earth metals and play a critical role in spin dynamics. However, detecting them in real time domain has been difficult. Here we show the direct evidence of IEC between 5d6s and 4f electrons in gadolinium. Upon femtosecond laser excitation, 5d6s electrons are directly excited; their majority bands shift toward the Fermi level while their minority bands do the opposite. For the first time, our first-principles minority shift now agrees with the experiment quantitatively. Excited 5d6s electrons lower the exchange potential barrier for 4f electrons, so the 4f states are also shifted in energy, a prediction that can be tested experimentally. Although a significant number of 5d6s electrons, some several eV below the Fermi level, are excited out of the Fermi sea, there is no change in the 4f states, a clear manifestation of intra-atomic exchange coupling.

  15. Current role of transcatheter arterial embolization for bladder and prostate hemorrhage.

    PubMed

    Loffroy, R; Pottecher, P; Cherblanc, V; Favelier, S; Estivalet, L; Koutlidis, N; Moulin, M; Cercueil, J P; Cormier, L; Krausé, D

    2014-11-01

    Intractable hematuria from the bladder or the prostate can be life-threatening and its management remains a difficult clinical problem. Severe bleeding can arise as a result of radiation cystitis, bladder carcinoma, cyclophosphamide-induced cystitis, severe infection, transurethral resection of the prostate and prostate cancer. When irrigation of the bladder through a three-way catheter and fulguration of the bleeding lesions fail to stop the hematuria, a life-threatening situation can develop, when blood transfusion fails to keep pace with the rate of blood loss. Patients with massive uncontrollable hematuria are often elderly and unfit for cystectomy as a treatment. Many urologists have had to manage this difficult problem, and several different treatments have been attempted and described, with varying degrees of success. Transcatheter arterial embolization of the vesical or prostatic arteries is occasionally indicated in these patients when all other measures have failed. There is limited published experience with this procedure, but success in 90% of patients is reported when the vesical or prostatic arteries can be identified. The aim of this review is to describe the current place of transcatheter arterial embolization in the management of severe bladder or prostate bleeding after failed conservative therapy, and to review its efficacy and morbidity. Copyright © 2014 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  16. Twoplex 12/13 C6 aniline stable isotope and linkage-specific sialic acid labeling 2D-LC-MS workflow for quantitative N-glycomics.

    PubMed

    Albrecht, Simone; Mittermayr, Stefan; Smith, Josh; Martín, Silvia Millán; Doherty, Margaret; Bones, Jonathan

    2017-01-01

    Quantitative glycomics represents an actively expanding research field ranging from the discovery of disease-associated glycan alterations to the quantitative characterization of N-glycans on therapeutic proteins. Commonly used analytical platforms for comparative relative quantitation of complex glycan samples include MALDI-TOF-MS or chromatographic glycan profiling with subsequent data alignment and statistical evaluation. Limitations of such approaches include run-to-run technical variation and the potential introduction of subjectivity during data processing. Here, we introduce an offline 2D LC-MS E workflow for the fractionation and relative quantitation of twoplex isotopically labeled N-linked oligosaccharides using neutral 12 C 6 and 13 C 6 aniline (Δmass = 6 Da). Additional linkage-specific derivatization of sialic acids using 4-(4,6-dimethoxy-1,3,5-trizain-2-yl)-4-methylmorpholinium chloride offered simultaneous and advanced in-depth structural characterization. The potential of the method was demonstrated for the differential analysis of structurally defined N-glycans released from serum proteins of patients diagnosed with various stages of colorectal cancer. The described twoplex 12 C 6 / 13 C 6 aniline 2D LC-MS platform is ideally suited for differential glycomic analysis of structurally complex N-glycan pools due to combination and analysis of samples in a single LC-MS injection and the associated minimization in technical variation. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. 4-D photoacoustic tomography.

    PubMed

    Xiang, Liangzhong; Wang, Bo; Ji, Lijun; Jiang, Huabei

    2013-01-01

    Photoacoustic tomography (PAT) offers three-dimensional (3D) structural and functional imaging of living biological tissue with label-free, optical absorption contrast. These attributes lend PAT imaging to a wide variety of applications in clinical medicine and preclinical research. Despite advances in live animal imaging with PAT, there is still a need for 3D imaging at centimeter depths in real-time. We report the development of four dimensional (4D) PAT, which integrates time resolutions with 3D spatial resolution, obtained using spherical arrays of ultrasonic detectors. The 4D PAT technique generates motion pictures of imaged tissue, enabling real time tracking of dynamic physiological and pathological processes at hundred micrometer-millisecond resolutions. The 4D PAT technique is used here to image needle-based drug delivery and pharmacokinetics. We also use this technique to monitor 1) fast hemodynamic changes during inter-ictal epileptic seizures and 2) temperature variations during tumor thermal therapy.

  18. Biomedical Impact in Implantable Devices-The Transcatheter Aortic Valve as an example

    NASA Astrophysics Data System (ADS)

    Anastasiou, Alexandros; Saatsakis, George

    2015-09-01

    Objective: To update of the scientific community about the biomedical engineering involvement in the implantable devices chain. Moreover the transcatheter Aortic Valve (TAV) replacement, in the field of cardiac surgery, will be analyzed as an example of contemporary implantable technology. Methods: A detailed literature review regarding biomedical engineers participating in the implantable medical product chain, starting from the design of the product till the final implantation technique. Results: The scientific role of biomedical engineers has clearly been established. Certain parts of the product chain are implemented almost exclusively by experienced biomedical engineers such as the transcatheter aortic valve device. The successful professional should have a multidisciplinary knowledge, including medicine, in order to pursue the challenges for such intuitive technology. This clearly indicates that biomedical engineers are among the most appropriate scientists to accomplish such tasks. Conclusions: The biomedical engineering involvement in medical implantable devices has been widely accepted by the scientific community, worldwide. Its important contribution, starting from the design and extended to the development, clinical trials, scientific support, education of other scientists (surgeons, cardiologists, technicians etc.), and even to sales, makes biomedical engineers a valuable player in the scientific arena. Notably, the sector of implantable devices is constantly raising, as emerging technologies continuously set up new targets.

  19. Importance of d-wave contributions in the charge symmetry breaking reaction dd →4Heπ0

    NASA Astrophysics Data System (ADS)

    Adlarson, P.; Augustyniak, W.; Bardan, W.; Bashkanov, M.; Bergmann, F. S.; Berłowski, M.; Bondar, A.; Büscher, M.; Calén, H.; Ciepał, I.; Clement, H.; Czerwiński, E.; Demmich, K.; Engels, R.; Erven, A.; Erven, W.; Eyrich, W.; Fedorets, P.; Föhl, K.; Fransson, K.; Goldenbaum, F.; Goswami, A.; Grigoryev, K.; Gullström, C.-O.; Hanhart, C.; Heijkenskjöld, L.; Hejny, V.; Hüsken, N.; Jarczyk, L.; Johansson, T.; Kamys, B.; Kemmerling, G.; Khatri, G.; Khoukaz, A.; Khreptak, O.; Kirillov, D. A.; Kistryn, S.; Kleines, H.; Kłos, B.; Krzemień, W.; Kulessa, P.; Kupść, A.; Kuzmin, A.; Lalwani, K.; Lersch, D.; Lorentz, B.; Magiera, A.; Maier, R.; Marciniewski, P.; Mariański, B.; Morsch, H.-P.; Moskal, P.; Ohm, H.; Parol, W.; Perez del Rio, E.; Piskunov, N. M.; Prasuhn, D.; Pszczel, D.; Pysz, K.; Pyszniak, A.; Ritman, J.; Roy, A.; Rudy, Z.; Rundel, O.; Sawant, S.; Schadmand, S.; Schätti-Ozerianska, I.; Sefzick, T.; Serdyuk, V.; Shwartz, B.; Sitterberg, K.; Skorodko, T.; Skurzok, M.; Smyrski, J.; Sopov, V.; Stassen, R.; Stepaniak, J.; Stephan, E.; Sterzenbach, G.; Stockhorst, H.; Ströher, H.; Szczurek, A.; Trzciński, A.; Wolke, M.; Wrońska, A.; Wüstner, P.; Yamamoto, A.; Zabierowski, J.; Zieliński, M. J.; Złomańczuk, J.; Żuprański, P.; Żurek, M.; WASA-at-COSY Collaboration

    2018-06-01

    This letter reports a first quantitative analysis of the contribution of higher partial waves in the charge symmetry breaking reaction dd →4Heπ0 using the WASA-at-COSY detector setup at an excess energy of Q = 60MeV. The determined differential cross section can be parametrized as d σ /d Ω = a + bcos2 ⁡θ*, where θ* is the production angle of the pion in the center-of-mass coordinate system, and the results for the parameters are a = (1.55 ± 0.46(stat) + 0.32 - 0.8 (syst)) pb /sr and b = (13.1 ± 2.1 (stat)-2.7+1.0 (syst)) pb /sr. The data are compatible with vanishing p-waves and a sizable d-wave contribution. This finding should strongly constrain the contribution of the Δ isobar to the dd →4Heπ0 reaction and is, therefore, crucial for a quantitative understanding of quark mass effects in nuclear production reactions.

  20. Solitary Hepatocellular Carcinoma Fed by the Cystic Artery: Limitation of Transcatheter Arterial Embolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hirota, Shozo; Matsumoto, Shinichi; Fukuda, Tetsuya

    1999-05-15

    Purpose: To clarify the limitations of transcatheter treatment for hepatocellular carcinoma (HCC) with parasitic feeders from the cystic artery. Methods: Three male patients had a solitary HCC (average diameter 3 cm) fed by the cystic artery among 221 patients with HCC from 1994 to 1997. One tumor was nourished entirely from the cystic artery arising from the medial branch of the left hepatic artery, and two tumors were fed partially by the cystic arteries arising from the anterior inferior branch of the right hepatic artery. We analyzed the indications for transcatheter treatment for these three patients. Results: We chose notmore » to embolize the cystic artery for fear of necrosis of the gallbladder. Although embolization of the anterior branch of the right hepatic artery was performed in one patient with a tumor fed partially by the cystic artery, only half the tumor was embolized. Two patients underwent hepatic resection, and one received percutaneous ethanol injection therapy. At follow-up of 28-40 months (average 33 months) all patients are alive. Conclusion: Feeding by the cystic artery represents a limitation of TAE for HCC.« less

  1. Artery and vein segmentation of the cerebral vasculature in 4D CT using a 3D fully convolutional neural network

    NASA Astrophysics Data System (ADS)

    Meijs, Midas; Manniesing, Rashindra

    2018-02-01

    Segmentation of the arteries and veins of the cerebral vasculature is important for improved visualization and for the detection of vascular related pathologies including arteriovenous malformations. We propose a 3D fully convolutional neural network (CNN) using a time-to-signal image as input and the distance to the center of gravity of the brain as spatial feature integrated in the final layers of the CNN. The method was trained and validated on 6 and tested on 4 4D CT patient imaging data. The reference standard was acquired by manual annotations by an experienced observer. Quantitative evaluation showed a mean Dice similarity coefficient of 0.94 +/- 0.03 and 0.97 +/- 0.01, a mean absolute volume difference of 4.36 +/- 5.47 % and 1.79 +/- 2.26 % for artery and vein respectively and an overall accuracy of 0.96 +/- 0.02. The average calculation time per volume on the test set was approximately one minute. Our method shows promising results and enables fast and accurate segmentation of arteries and veins in full 4D CT imaging data.

  2. Contrast-enhanced time-resolved 4D MRA of congenital heart and vessel anomalies: image quality and diagnostic value compared with 3D MRA.

    PubMed

    Vogt, Florian M; Theysohn, Jens M; Michna, Dariusz; Hunold, Peter; Neudorf, Ulrich; Kinner, Sonja; Barkhausen, Jörg; Quick, Harald H

    2013-09-01

    To evaluate time-resolved interleaved stochastic trajectories (TWIST) contrast-enhanced 4D magnetic resonance angiography (MRA) and compare it with 3D FLASH MRA in patients with congenital heart and vessel anomalies. Twenty-six patients with congenital heart and vessel anomalies underwent contrast-enhanced MRA with both 3D FLASH and 4D TWIST MRA. Images were subjectively evaluated regarding total image quality, artefacts, diagnostic value and added diagnostic value of 4D dynamic imaging. Quantitative comparison included signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and vessel sharpness measurements. Three-dimensional FLASH MRA was judged to be significantly better in terms of image quality (4.0 ± 0.6 vs 3.4 ± 0.6, P < 0.05) and artefacts (3.8 ± 0.4 vs 3.3 ± 0.5, P < 0.05); no difference in diagnostic value was found (4.2 ± 0.4 vs 4.0 ± 0.4); important additional functional information was found in 21/26 patients. SNR and CNR were higher in the pulmonary trunk in 4D TWIST, but slightly higher in the systemic arteries in 3D FLASH. No difference in vessel sharpness delineation was found. Although image quality was inferior compared with 3D FLASH MRA, 4D TWIST MRA yields robust images and added diagnostic value through dynamic acquisition was found. Thus, 4D TWIST MRA is an attractive alternative to 3D FLASH MRA. • New magnetic resonance angiography (MRA) techniques are increasingly introduced for congenital cardiovascular problems. • Time-resolved angiography with interleaved stochastic trajectories (TWIST) is an example. • Four-dimensional TWIST MRA provided inferior image quality compared to 3D FLASH MRA but without significant difference in vessel sharpness. • Four-dimensional TWIST MRA gave added diagnostic value.

  3. Transcatheter Embolization of a Large Symptomatic Pelvic Arteriovenous Malformation with Glubran 2 Acrylic Glue

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gandini, R.; Angelopoulos, G., E-mail: giorginos78@msn.com; Konda, D.

    A young patient affected by a pelvic arteriovenous malformation (pAVM) with recurrent episodes of hematuria following exercise, underwent transcatheter embolization using Glubran 2 acrylic glue (GEM, Viareggio, Italy). All branches of the pAVM were successfully occluded. The patient showed prompt resolution of symptoms and persistent occlusion of the pAVM at the 6 month follow-up.

  4. Quantitative DWI implemented after DCE-MRI yields increased specificity for BI-RADS 3 and 4 breast lesions.

    PubMed

    Dijkstra, Hildebrand; Dorrius, Monique D; Wielema, Mirjam; Pijnappel, Ruud M; Oudkerk, Matthijs; Sijens, Paul E

    2016-12-01

    To assess if specificity can be increased when semiautomated breast lesion analysis of quantitative diffusion-weighted imaging (DWI) is implemented after dynamic contrast-enhanced (DCE-) magnetic resonance imaging (MRI) in the workup of BI-RADS 3 and 4 breast lesions larger than 1 cm. In all, 120 consecutive patients (mean-age, 48 years; age range, 23-75 years) with 139 breast lesions (≥1 cm) were examined (2010-2014) with 1.5T DCE-MRI and DWI (b = 0, 50, 200, 500, 800, 1000 s/mm 2 ) and the BI-RADS classification and histopathology were obtained. For each lesion malignancy was excluded using voxelwise semiautomated breast lesion analysis based on previously defined thresholds for the apparent diffusion coefficient (ADC) and the three intravoxel incoherent motion (IVIM) parameters: molecular diffusion (D slow ), microperfusion (D fast ), and the fraction of D fast (f fast ). The sensitivity (Se), specificity (Sp), and negative predictive value (NPV) based on only IVIM parameters combined in parallel (D slow , D fast , and f fast ), or the ADC or the BI-RADS classification by DCE-MRI were compared. Subsequently, the Se, Sp, and NPV of the combination of the BI-RADS classification by DCE-MRI followed by the IVIM parameters in parallel (or the ADC) were compared. In all, 23 of 139 breast lesions were benign. Se and Sp of DCE-MRI was 100% and 30.4% (NPV = 100%). Se and Sp of IVIM parameters in parallel were 92.2% and 52.2% (NPV = 57.1%) and for the ADC 95.7% and 17.4%, respectively (NPV = 44.4%). In all, 26 of 139 lesions were classified as BI-RADS 3 (n = 7) or BI-RADS 4 (n = 19). DCE-MRI combined with ADC (Se = 99.1%, Sp = 34.8%) or IVIM (Se = 99.1%, Sp = 56.5%) did significantly improve (P = 0.016) Sp of DCE-MRI alone for workup of BI-RADS 3 and 4 lesions (NPV = 92.9%). Quantitative DWI has a lower NPV compared to DCE-MRI for evaluation of breast lesions and may therefore not be able to replace DCE-MRI; when

  5. Massive Hematochezia: A Complication of Methamphetamine-Induced Vasculitis Treated by Transcatheter Hemostasis

    PubMed Central

    Link, Daniel P.; Chi, Yung-Wei

    2011-01-01

    A long-term, heavy methamphetamine user with life-threatening rectal hemorrhage was treated with transcatheter occlusion of the bleeding arteries. The bleeding blood vessels were vulnerable submucosal arteries, part of the collateral supply to the distal colon. Visceral arteriography demonstrates severe arterial stenotic lesions of the celiac axis, superior mesenteric artery and the inferior mesenteric artery. Collateral vessels were seen with corkscrew morphology similar to that seen with thromboangiitis obliterans. PMID:22606562

  6. Injuries to the Aorta, Aortic Annulus, and Left Ventricle During Transcatheter Aortic Valve Replacement: Management and Outcomes.

    PubMed

    Langer, Nathaniel B; Hamid, Nadira B; Nazif, Tamim M; Khalique, Omar K; Vahl, Torsten P; White, Jonathon; Terre, Juan; Hastings, Ramin; Leung, Diana; Hahn, Rebecca T; Leon, Martin; Kodali, Susheel; George, Isaac

    2017-01-01

    The experience with transcatheter aortic valve replacement is increasing worldwide; however, the incidence of potentially catastrophic cardiac or aortic complications has not decreased. In most cases, significant injuries to the aorta, aortic valve annulus, and left ventricle require open surgical repair. However, the transcatheter aortic valve replacement patient presents a unique challenge as many patients are at high or prohibitive surgical risk and, therefore, an open surgical procedure may not be feasible or appropriate. Consequently, prevention of these potentially catastrophic injuries is vital, and practitioners need to understand when open surgical repair is required and when alternative management strategies can be used. The goal of this article is to provide an overview of current management and prevention strategies for major complications involving the aorta, aortic valve annulus, and left ventricle. © 2016 American Heart Association, Inc.

  7. The JUPITER registry: One-year outcomes of transapical aortic valve implantation using a second generation transcatheter heart valve for aortic regurgitation.

    PubMed

    Silaschi, Miriam; Conradi, Lenard; Wendler, Olaf; Schlingloff, Friederike; Kappert, Utz; Rastan, Ardawan J; Baumbach, Hardy; Holzhey, David; Eichinger, Walter; Bader, Ralf; Treede, Hendrik

    2018-06-01

    We present 1-year outcomes of the post-market registry of a next-generation transcatheter heart valve used for aortic regurgitation (AR). Transcatheter aortic valve replacement (TAVR) is routine in high-risk patients with aortic stenosis but is not recommended for AR. The JenaValve™ (JenaValve Technology GmbH, Munich, Germany) overcomes technical challenges in AR patients through a leaflet clipping mechanism. The JenaValve EvalUation of Long Term Performance and Safety In PaTients with SEvere Aortic Stenosis oR Aortic Insufficiency (JUPITER) Registry is a European study to evaluate safety and effectiveness of this THV. From 2012-2015, 30 patients with AR were enrolled. Mean age was 74.4 ± 9.3 years. Procedural success was 96.7% (29/30). One patient was converted to open surgery. No annular rupture or coronary ostia obstruction occurred. Mortality at 30 days was 10.0% (3/30). Combined safety endpoint was met in 13.3% (4/30). Paravalvular regurgitation was not present/trivial in 84.6% (22/26) and mild in 15.4% (4/26). Rate of permanent pacemaker implantation was 3.8% (1/26). One-year Kaplan-Meier survival was 79.9%, one-year combined efficacy was 73.1% (19/30). No further strokes were observed during 1 year of follow-up. The JenaValve overcomes technical challenges of TAVR in AR through a clipping mechanism. We report satisfactory outcomes of a multicenter registry using the JenaValve for predominant AR, as rate of THV embolization, residual AR and permanent pacemaker implantation was low. One-year results using the JenaValve for AR encourage its use for this indication. © 2017 Wiley Periodicals, Inc.

  8. RenalGuard System for the prevention of acute kidney injury in patients undergoing transcatheter aortic valve implantation.

    PubMed

    Visconti, Gabriella; Focaccio, Amelia; Donahue, Michael; Golia, Bruno; Marzano, Antonio; Donnarumma, Elvira; Ricciardelli, Bruno; Selvetella, Lucio; Marino, Luigi; Briguori, Carlo

    2016-04-08

    We aimed to assess whether the RenalGuard™ System is effective in preventing acute kidney injury (AKI) following transcatheter aortic valve implantation (TAVI). Forty-eight consecutive patients with chronic kidney disease (CKD) scheduled for TAVI were assigned to: 1) hydration with sodium bicarbonate solution (Control group), or 2) hydration with RenalGuard Therapy (RenalGuard group). Hypotension was defined as periprocedural mean blood pressure <55 mmHg. The primary endpoint was the occurrence of AKI (i.e., an increase of ≥0.3 mg/dL in the serum creatinine concentration at seven days). AKI occurred in 10/26 (38.5%) patients in the Control group and in 1/22 (4.5%) patients in the RenalGuard group (p=0.005, odds ratio [OR] 0.076, 95% confidence interval [CI]: 0.009-0.66). RenalGuard Therapy protected against AKI (OR 0.71, 95% CI: 0.07-0.775, p=0.026), whereas post-procedural hypotension (OR 3.88, 95% CI: 1.06-14.24, p=0.040), and contrast media volume (OR 3.65, 95% CI: 1.15-5.75, p=0.043) increased the risk of AKI. This non-randomised pilot study suggests that RenalGuard Therapy may be effective in preventing AKI in CKD patients undergoing TAVI.

  9. Quantitative Live-Cell Confocal Imaging of 3D Spheroids in a High-Throughput Format.

    PubMed

    Leary, Elizabeth; Rhee, Claire; Wilks, Benjamin T; Morgan, Jeffrey R

    2018-06-01

    Accurately predicting the human response to new compounds is critical to a wide variety of industries. Standard screening pipelines (including both in vitro and in vivo models) often lack predictive power. Three-dimensional (3D) culture systems of human cells, a more physiologically relevant platform, could provide a high-throughput, automated means to test the efficacy and/or toxicity of novel substances. However, the challenge of obtaining high-magnification, confocal z stacks of 3D spheroids and understanding their respective quantitative limitations must be overcome first. To address this challenge, we developed a method to form spheroids of reproducible size at precise spatial locations across a 96-well plate. Spheroids of variable radii were labeled with four different fluorescent dyes and imaged with a high-throughput confocal microscope. 3D renderings of the spheroid had a complex bowl-like appearance. We systematically analyzed these confocal z stacks to determine the depth of imaging and the effect of spheroid size and dyes on quantitation. Furthermore, we have shown that this loss of fluorescence can be addressed through the use of ratio imaging. Overall, understanding both the limitations of confocal imaging and the tools to correct for these limits is critical for developing accurate quantitative assays using 3D spheroids.

  10. Attenuation correction in 4D-PET using a single-phase attenuation map and rigidity-adaptive deformable registration

    PubMed Central

    Kalantari, Faraz; Wang, Jing

    2017-01-01

    Purpose Four-dimensional positron emission tomography (4D-PET) imaging is a potential solution to the respiratory motion effect in the thoracic region. Computed tomography (CT)-based attenuation correction (AC) is an essential step toward quantitative imaging for PET. However, due to the temporal difference between 4D-PET and a single attenuation map from CT, typically available in routine clinical scanning, motion artifacts are observed in the attenuation-corrected PET images, leading to errors in tumor shape and uptake. We introduced a practical method to align single-phase CT with all other 4D-PET phases for AC. Methods A penalized non-rigid Demons registration between individual 4D-PET frames without AC provides the motion vectors to be used for warping single-phase attenuation map. The non-rigid Demons registration was used to derive deformation vector fields (DVFs) between PET matched with the CT phase and other 4D-PET images. While attenuated PET images provide useful data for organ borders such as those of the lung and the liver, tumors cannot be distinguished from the background due to loss of contrast. To preserve the tumor shape in different phases, an ROI-covering tumor was excluded from non-rigid transformation. Instead the mean DVF of the central region of the tumor was assigned to all voxels in the ROI. This process mimics a rigid transformation of the tumor along with a non-rigid transformation of other organs. A 4D-XCAT phantom with spherical lung tumors, with diameters ranging from 10 to 40 mm, was used to evaluate the algorithm. The performance of the proposed hybrid method for attenuation map estimation was compared to 1) the Demons non-rigid registration only and 2) a single attenuation map based on quantitative parameters in individual PET frames. Results Motion-related artifacts were significantly reduced in the attenuation-corrected 4D-PET images. When a single attenuation map was used for all individual PET frames, the normalized root mean

  11. 3D/4D multiscale imaging in acute lymphoblastic leukemia cells: visualizing dynamics of cell death

    NASA Astrophysics Data System (ADS)

    Sarangapani, Sreelatha; Mohan, Rosmin Elsa; Patil, Ajeetkumar; Lang, Matthew J.; Asundi, Anand

    2017-06-01

    Quantitative phase detection is a new methodology that provides quantitative information on cellular morphology to monitor the cell status, drug response and toxicity. In this paper the morphological changes in acute leukemia cells treated with chitosan were detected using d'Bioimager a robust imaging system. Quantitative phase image of the cells was obtained with numerical analysis. Results show that the average area and optical volume of the chitosan treated cells is significantly reduced when compared with the control cells, which reveals the effect of chitosan on the cancer cells. From the results it can be attributed that d'Bioimager can be used as a non-invasive imaging alternative to measure the morphological changes of the living cells in real time.

  12. Updated clinical indications for transcatheter aortic valve implantation in patients with severe aortic stenosis: expert opinion of the Italian Society of Cardiology and GISE.

    PubMed

    Indolfi, Ciro; Bartorelli, Antonio L; Berti, Sergio; Golino, Paolo; Esposito, Giovanni; Musumeci, Giuseppe; Petronio, Sonia; Tamburino, Corrado; Tarantini, Giuseppe; Ussia, Gianpaolo; Vassanelli, Corrado; Spaccarotella, Carmen; Violini, Roberto; Mercuro, Giuseppe; Romeo, Francesco

    2018-05-01

    : The introduction of percutaneous treatment of severe aortic stenosis with transcatheter aortic valve implantation (TAVI) remains one of the greatest achievements of interventional cardiology. In fact, TAVI emerged as a better option than either medical therapy or balloon aortic valvuloplasty for patients who cannot undergo surgical aortic valve replacement (SAVR) or are at high surgical risk. Recently, increased operator experience and improved device systems have led to a worldwide trend toward the extension of TAVI to low-risk or intermediate-risk patients. In this expert opinion paper, we first discuss the basic pathophysiology of aortic stenosis in different settings then the key results of recent clinical investigations on TAVI in intermediate-risk aortic stenosis patients are summarized. Particular emphasis is placed on the results of the nordic aortic valve intervention, placement of aortic transcatheter valves (PARTNER) 2 and Surgical Replacement and Transcatheter Aortic Valve Implantation Randomized trials. The PARTNER 2 was the first large randomized trial that evaluated the outcome of TAVI in patients at intermediate risk. The PARTNER 2 data demonstrated that TAVI is a feasible and reasonable alternative to surgery in intermediate-risk patients (Society of Thoracic Surgeons 4-8%), especially if they are elderly or frail. There was a significant interaction between TAVI approach and mortality, with transfemoral TAVI showing superiority over SAVR. Moreover, we examine the complementary results of the recently concluded Surgical Replacement and Transcatheter Aortic Valve Implantation trial. This prospective randomized trial demonstrated that TAVI is comparable with surgery (primary end point 12.6% in the TAVI group vs. 14.0% in the SAVR group) in severe aortic stenosis patients deemed to be at intermediate risk. We review the most relevant clinical evidence deriving from nonrandomized studies and meta-analyses. Altogether, clinical outcome available data

  13. Predictive ability of the CHADS2 and CHA2DS2-VASc scores for stroke after transcatheter aortic balloon-expandable valve implantation: an Italian Transcatheter Balloon-Expandable Valve Implantation Registry (ITER) sub-analysis.

    PubMed

    Conrotto, Federico; D'Ascenzo, Fabrizio; D'Onofrio, Augusto; Agrifoglio, Marco; Chieffo, Alaide; Cioni, Micaela; Regesta, Tommaso; Tarantini, Giuseppe; Gabbieri, Davide; Saia, Francesco; Tamburino, Corrado; Ribichini, Flavio; Cugola, Diego; Aiello, Marco; Sanna, Francesco; Iadanza, Alessandro; Pompei, Esmeralda; Stolcova, Miroslava; Cappai, Antioco; Minati, Alessandro; Cassese, Mauro; Martinelli, Gian Luca; Agostinelli, Andrea; Gerosa, Gino; Gaita, Fiorenzo; Rinaldi, Mauro; Salizzoni, Stefano

    2016-11-01

    Stroke incidence after transcatheter aortic valve implantation (TAVI) still represents a concern. This multicentre study aimed at investigating the hypothesis that CHADS2 and CHA2DS2-VASc scores may be used to predict perioperative stroke after TAVI. The Italian Transcatheter Balloon-Expandable Valve Implantation Registry (ITER) is a multicentre, prospective registry of patients undergoing balloon-expandable TAVI using Edwards Sapien and Sapien XT prosthesis between 2007 and 2012. The primary end-point of this study was the 30-day stroke rate. Secondary safety end-points were all the major adverse events based on Valve Academic Research Consortium (VARC-2) criteria. One thousand nine hundred and four patients were enrolled in the registry. Mean age was 81.6 ± 6.2 years and 1147 (60.2%) patients were female; mean CHADS 2 and CHA 2 DS 2 -VASc scores were 2.2 ± 0.8 and 4.4 ± 1.1, respectively. Fifty-four (2.8%) patients had a stroke within 30 days. At multivariable logistic regression analysis, CHA 2 DS 2 -VASc (OR: 1.35, 95% CI: 1.03-1.78; P = 0.031) and previous cardiac surgery (OR: 1.96, 95% CI: 1.06-3.6; P = 0.033) but not CHADS 2 (OR: 1.05, 95% CI: 0.76-1.44; P = 0.77) were found to be independent predictors of in-hospital stroke. A CHA 2 DS 2 -VASc score ≥5 was strongly related to the occurrence of in-hospital stroke (OR: 2.51, 95% CI: 1.38-4.57; P= 0.001). However, CHA 2 DS 2 -VASc score showed only poor accuracy for in-hospital stroke with a trend for better accuracy when compared with CHADS 2 score (area under the curve: 0.61, 95% CI: 0.59-0.63 vs 0.51; 95% CI: 0.49-0.54, respectively, P = 0.092). In TAVI patients, CHA 2 DS 2 -VASc provided a strong correlation for in-hospital stroke but with low accuracy. Dedicated scores to properly tailor procedures and preventive strategies are needed. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  14. Accelerated 4D self-gated MRI of tibiofemoral kinematics.

    PubMed

    Mazzoli, Valentina; Schoormans, Jasper; Froeling, Martijn; Sprengers, Andre M; Coolen, Bram F; Verdonschot, Nico; Strijkers, Gustav J; Nederveen, Aart J

    2017-11-01

    Anatomical (static) magnetic resonance imaging (MRI) is the most useful imaging technique for the evaluation and assessment of internal derangement of the knee, but does not provide dynamic information and does not allow the study of the interaction of the different tissues during motion. As knee pain is often only experienced during dynamic tasks, the ability to obtain four-dimensional (4D) images of the knee during motion could improve the diagnosis and provide a deeper understanding of the knee joint. In this work, we present a novel approach for dynamic, high-resolution, 4D imaging of the freely moving knee without the need for external triggering. The dominant knee of five healthy volunteers was scanned during a flexion/extension task. To evaluate the effects of non-uniform motion and poor coordination skills on the quality of the reconstructed images, we performed a comparison between fully free movement and movement instructed by a visual cue. The trigger signal for self-gating was extracted using principal component analysis (PCA), and the images were reconstructed using a parallel imaging and compressed sensing reconstruction pipeline. The reconstructed 4D movies were scored for image quality and used to derive bone kinematics through image registration. Using our method, we were able to obtain 4D high-resolution movies of the knee without the need for external triggering hardware. The movies obtained with and without instruction did not differ significantly in terms of image scoring and quantitative values for tibiofemoral kinematics. Our method showed to be robust for the extraction of the self-gating signal even for uninstructed motion. This can make the technique suitable for patients who, as a result of pain, may find it difficult to comply exactly with instructions. Furthermore, bone kinematics can be derived from accelerated MRI without the need for additional hardware for triggering. Copyright © 2017 John Wiley & Sons, Ltd.

  15. High-risk Trans-Catheter Aortic Valve Replacement in a Failed Freestyle Valve with Low Coronary Height: A Case Report.

    PubMed

    Karimi, Ashkan; Pourafshar, Negiin; Dibu, George; Beaver, Thomas M; Bavry, Anthony A

    2017-06-01

    A 55-year-old male with a history of two prior cardiac surgeries presented with decompensated heart failure due to severe bioprosthetic aortic valve insufficiency. A third operation was viewed prohibitively high risk and valve-in-valve trans-catheter aortic valve replacement was considered. There were however several high-risk features and technically challenging aspects including low coronary ostia height, poor visualization of the aortic sinuses, and difficulty in identification of the coplanar view due to severe aortic insufficiency, and a highly mobile aortic valve mass. After meticulous peri-procedural planning, trans-catheter aortic valve replacement was carried out with a SAPIEN 3 balloon-expandable valve without any complication. Strategies undertaken to navigate the technically challenging aspects of the case are discussed.

  16. A differential mobility spectrometry/mass spectrometry platform for the rapid detection and quantitation of DNA adduct dG-ABP.

    PubMed

    Kafle, Amol; Klaene, Joshua; Hall, Adam B; Glick, James; Coy, Stephen L; Vouros, Paul

    2013-07-15

    There is continued interest in exploring new analytical technologies for the detection and quantitation of DNA adducts, biomarkers which provide direct evidence of exposure and genetic damage in cells. With the goal of reducing clean-up steps and improving sample throughput, a Differential Mobility Spectrometry/Mass Spectrometry (DMS/MS) platform has been introduced for adduct analysis. A DMS/MS platform has been utilized for the analysis of dG-ABP, the deoxyguanosine adduct of the bladder carcinogen 4-aminobiphenyl (4-ABP). After optimization of the DMS parameters, each sample was analyzed in just 30 s following a simple protein precipitation step of the digested DNA. A detection limit of one modification in 10^6 nucleosides has been achieved using only 2 µg of DNA. A brief comparison (quantitative and qualitative) with liquid chromatography/mass spectrometry is also presented highlighting the advantages of using the DMS/MS method as a high-throughput platform. The data presented demonstrate the successful application of a DMS/MS/MS platform for the rapid quantitation of DNA adducts using, as a model analyte, the deoxyguanosine adduct of the bladder carcinogen 4-aminobiphenyl. Copyright © 2013 John Wiley & Sons, Ltd.

  17. SPIO-labeled Yttrium Microspheres for MR Imaging Quantification of Transcatheter Intrahepatic Delivery in a Rodent Model

    PubMed Central

    Li, Weiguo; Zhang, Zhuoli; Gordon, Andrew C.; Chen, Jeane; Nicolai, Jodi; Lewandowski, Robert J.; Omary, Reed A.

    2016-01-01

    Purpose To investigate the qualitative and quantitative impacts of labeling yttrium microspheres with increasing amounts of superparamagnetic iron oxide (SPIO) material for magnetic resonance (MR) imaging in phantom and rodent models. Materials and Methods Animal model studies were approved by the institutional Animal Care and Use Committee. The r2* relaxivity for each of four microsphere SPIO compositions was determined from 32 phantoms constructed with agarose gel and in eight concentrations from each of the four compositions. Intrahepatic transcatheter infusion procedures were performed in rats by using each of the four compositions before MR imaging to visualize distributions within the liver. For quantitative studies, doses of 5, 10, 15, or 20 mg 2% SPIO-labeled yttrium microspheres were infused into 24 rats (six rats per group). MR imaging R2* measurements were used to quantify the dose delivered to each liver. Pearson correlation, analysis of variance, and intraclass correlation analyses were performed to compare MR imaging measurements in phantoms and animal models. Results Increased r2* relaxivity was observed with incremental increases of SPIO microsphere content. R2* measurements of the 2% SPIO–labeled yttrium microsphere concentration were well correlated with known phantom concentrations (R2 = 1.00, P < .001) over a broader linear range than observed for the other three compositions. Microspheres were heterogeneously distributed within each liver; increasing microsphere SPIO content produced marked signal voids. R2*-based measurements of 2% SPIO–labeled yttrium microsphere delivery were well correlated with infused dose (intraclass correlation coefficient, 0.98; P < .001). Conclusion MR imaging R2* measurements of yttrium microspheres labeled with 2% SPIO can quantitatively depict in vivo intrahepatic biodistribution in a rat model. © RSNA, 2015 Online supplemental material is available for this article. PMID:26313619

  18. Biokinetic Analysis and Metabolic Fate of 2,4-D in 2,4-D-Resistant Soybean (Glycine max).

    PubMed

    Skelton, Joshua J; Simpson, David M; Peterson, Mark A; Riechers, Dean E

    2017-07-26

    The Enlist weed control system allows the use of 2,4-D in soybean but slight necrosis in treated leaves may be observed in the field. The objectives of this research were to measure and compare uptake, translocation, and metabolism of 2,4-D in Enlist (E, resistant) and non-AAD-12 transformed (NT, sensitive) soybeans. The adjuvant from the Enlist Duo herbicide formulation (ADJ) increased 2,4-D uptake (36%) and displayed the fastest rate of uptake (U 50 = 0.2 h) among treatments. E soybean demonstrated a faster rate of 2,4-D metabolism (M 50 = 0.2 h) compared to NT soybean, but glyphosate did not affect 2,4-D metabolism. Metabolites of 2,4-D in E soybean were qualitatively different than NT. Applying 2,4-D-ethylhexyl ester instead of 2,4-D choline (a quaternary ammonium salt) eliminated visual injury to E soybean, likely due to the time required for initial de-esterification and bioactivation. Excessive 2,4-D acid concentrations in E soybean resulting from ADJ-increased uptake may significantly contribute to foliar injury.

  19. Respiratory motion resolved, self-gated 4D-MRI using Rotating Cartesian K-space (ROCK)

    PubMed Central

    Han, Fei; Zhou, Ziwu; Cao, Minsong; Yang, Yingli; Sheng, Ke; Hu, Peng

    2017-01-01

    Purpose To propose and validate a respiratory motion resolved, self-gated (SG) 4D-MRI technique to assess patient-specific breathing motion of abdominal organs for radiation treatment planning. Methods The proposed 4D-MRI technique was based on the balanced steady-state free-precession (bSSFP) technique and 3D k-space encoding. A novel ROtating Cartesian K-space (ROCK) reordering method was designed that incorporates repeatedly sampled k-space centerline as the SG motion surrogate and allows for retrospective k-space data binning into different respiratory positions based on the amplitude of the surrogate. The multiple respiratory-resolved 3D k-space data were subsequently reconstructed using a joint parallel imaging and compressed sensing method with spatial and temporal regularization. The proposed 4D-MRI technique was validated using a custom-made dynamic motion phantom and was tested in 6 healthy volunteers, in whom quantitative diaphragm and kidney motion measurements based on 4D-MRI images were compared with those based on 2D-CINE images. Results The 5-minute 4D-MRI scan offers high-quality volumetric images in 1.2×1.2×1.6mm3 and 8 respiratory positions, with good soft-tissue contrast. In phantom experiments with triangular motion waveform, the motion amplitude measurements based on 4D-MRI were 11.89% smaller than the ground truth, whereas a −12.5% difference was expected due to data binning effects. In healthy volunteers, the difference between the measurements based on 4D-MRI and the ones based on 2D-CINE were 6.2±4.5% for the diaphragm, 8.2±4.9% and 8.9±5.1% for the right and left kidney. Conclusion The proposed 4D-MRI technique could provide high resolution, high quality, respiratory motion resolved 4D images with good soft-tissue contrast and are free of the “stitching” artifacts usually seen on 4D-CT and 4D-MRI based on resorting 2D-CINE. It could be used to visualize and quantify abdominal organ motion for MRI-based radiation treatment

  20. Respiratory motion-resolved, self-gated 4D-MRI using rotating cartesian k-space (ROCK).

    PubMed

    Han, Fei; Zhou, Ziwu; Cao, Minsong; Yang, Yingli; Sheng, Ke; Hu, Peng

    2017-04-01

    To propose and validate a respiratory motion resolved, self-gated (SG) 4D-MRI technique to assess patient-specific breathing motion of abdominal organs for radiation treatment planning. The proposed 4D-MRI technique was based on the balanced steady-state free-precession (bSSFP) technique and 3D k-space encoding. A novel rotating cartesian k-space (ROCK) reordering method was designed which incorporates repeatedly sampled k-space centerline as the SG motion surrogate and allows for retrospective k-space data binning into different respiratory positions based on the amplitude of the surrogate. The multiple respiratory-resolved 3D k-space data were subsequently reconstructed using a joint parallel imaging and compressed sensing method with spatial and temporal regularization. The proposed 4D-MRI technique was validated using a custom-made dynamic motion phantom and was tested in six healthy volunteers, in whom quantitative diaphragm and kidney motion measurements based on 4D-MRI images were compared with those based on 2D-CINE images. The 5-minute 4D-MRI scan offers high-quality volumetric images in 1.2 × 1.2 × 1.6 mm 3 and eight respiratory positions, with good soft-tissue contrast. In phantom experiments with triangular motion waveform, the motion amplitude measurements based on 4D-MRI were 11.89% smaller than the ground truth, whereas a -12.5% difference was expected due to data binning effects. In healthy volunteers, the difference between the measurements based on 4D-MRI and the ones based on 2D-CINE were 6.2 ± 4.5% for the diaphragm, 8.2 ± 4.9% and 8.9 ± 5.1% for the right and left kidney. The proposed 4D-MRI technique could provide high-resolution, high-quality, respiratory motion-resolved 4D images with good soft-tissue contrast and are free of the "stitching" artifacts usually seen on 4D-CT and 4D-MRI based on resorting 2D-CINE. It could be used to visualize and quantify abdominal organ motion for MRI-based radiation treatment planning. © 2017 American

  1. SU-E-T-624: Quantitative Evaluation of 2D Versus 3D Dosimetry for Stereotactic Volumetric Modulated Arc Delivery Using COMPASS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vikraman, S; Karrthick, K; Rajesh, T

    2014-06-15

    Purpose: The purpose of this study was to evaluate quantitatively 2D versus 3D dosimetry for stereotactic volumetric modulated arc delivery using COMPASS with 2D array. Methods: Twenty-five patients CT images and RT structures of different sites like brain, head and neck, thorax, abdomen and spine were taken from Multiplan planning system for this study. All these patients underwent radical stereotactic treatment in Cyberknife. For each patient, linac based VMAT stereotactic plans were generated in Monaco TPS v 3.1 using Elekta Beam Modulator MLC. Dose prescription was in the range of 5-20Gy/fraction.TPS calculated VMAT plan delivery accuracy was quantitatively evaluated withmore » COMPASS measured dose and calculated dose based on DVH metrics. In order to ascertain the potential of COMPASS 3D dosimetry for stereotactic plan delivery, 2D fluence verification was performed with MatriXX using Multicube. Results: For each site, D{sub 9} {sub 5} was achieved with 100% of prescription dose with maximum 0.05SD. Conformity index (CI) was observed closer to 1.15 in all cases. Maximum deviation of 2.62 % was observed for D{sub 9} {sub 5} when compared TPS versus COMPASS measured. Considerable deviations were observed in head and neck cases compare to other sites. The maximum mean and standard deviation for D{sub 9} {sub 5}, average target dose and average gamma were -0.78±1.72, -1.10±1.373 and 0.39±0.086 respectively. Numbers of pixels passing 2D fluence verification were observed as a mean of 99.36% ±0.455 SD with 3% dose difference and 3mm DTA. For critical organs in head and neck cases, significant dose differences were observed in 3D dosimetry while the target doses were matched well within limit in both 2D and 3D dosimetry. Conclusion: The quantitative evaluations of 2D versus 3D dosimetry for stereotactic volumetric modulated plans showed the potential of highlighting the delivery errors. This study reveals that COMPASS 3D dosimetry is an effective tool for

  2. Transfemoral Implantation of a Fully Repositionable and Retrievable Transcatheter Valve for Noncalcified Pure Aortic Regurgitation.

    PubMed

    Schofer, Joachim; Nietlispach, Fabian; Bijuklic, Klaudija; Colombo, Antonio; Gatto, Fernando; De Marco, Federico; Mangieri, Antonio; Hansen, Lorenz; Bruschi, Giuseppe; Ruparelia, Neil; Rieß, Friedrich-Christian; Maisano, Franscesco; Latib, Azeem

    2015-12-21

    This study sought to evaluate the use of the Direct Flow Medical (DFM) transcatheter heart valve (Direct Flow Medical, Santa Rosa, California) for the treatment of noncalcific pure aortic regurgitation (AR). The treatment of noncalcific AR has remained a relative contraindication with transcatheter heart valves due to challenges in anchoring devices in the absence of calcium, concerns of valve embolization, and the high risk of significant residual paravalvular leak. The study population consisted of patients treated for severe noncalcific pure AR with transfemoral implantation of a DFM transcatheter heart valve at 6 European centers. The primary endpoint was the composite endpoint of device success and the secondary endpoint was the composite early safety endpoint (according to the VARC-2 criteria). Eleven high-risk (STS score 8.84 ± 8.9, Logistic EuroSCORE 19.9 ± 7.1) patients (mean age 74.7 ± 12.9 years) were included. Device success was achieved in all patients. In 1 patient, the initial valve prosthesis was retrieved after pull-through, and a second valve was successfully deployed. The early safety endpoint was reached in 91% of the patients, with 1 patient requiring surgical aortic valve replacement secondary to downward dislocation of the prosthesis that was successfully managed with surgical aortic valve replacement. DFM implantation resulted in excellent hemodynamics with none or trivial paravalvular regurgitation in 9 patients and a transprosthetic gradient of 7.7 ± 5.1 mm Hg at 30-day follow up. All patients derived symptomatic benefit following the procedure, with 72% in New York Heart Association functional class I or II. This study reports the feasibility of treating severe noncalcific AR with the Direct Flow prosthesis via the transfemoral route. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  3. A convenient synthesis of 6-amino-1-beta-D-ribofuranosylpyrazolo[3,4-d]pyrimidin-4-one and related 4,6-disubstituted pyrazolopyrimidine nucleosides.

    PubMed Central

    Cottam, H B; Revankar, G R; Robins, R K

    1983-01-01

    The glycosylation of 4,6-dichloropyrazolo[3,4-d]pyrimidine and 4-chloro-6-methylthiopyrazolo[3,4-d]pyrimidine via the corresponding trimethylsilyl intermediate and tetra-O-acetyl-beta-D-ribofuranose in the presence of trimethylsilyl triflate as a catalyst, gave selective glycosylation at N1 as the only nucleoside product. The intermediates 4,6-dichloro-1-(2,3,5-tri-O-acetyl-beta-D-ribofuranosyl)pyrazolo [3,4-d]pyrimidine 7 and 4-chloro-6-methylthio-1-(2,3,5-tri-O-acetyl-beta-D-ribofuranosyl)pyrazolo [3,4-d]pyrimidine 13 gave new and convenient synthetic routes to the inosine analog 1, the guanosine analog 2, the adenosine analog 3, and the isoguanosine analog 16. Glycosylation of the trimethylsilyl derivative of 6-chloropyrazolo[3,4-d]pyrimidine-4-one unexpectedly gave the N2-glycosyl isomer 20 as the major product. A number of new 4,6-disubstituted pyrazolo[3,4-d]pyrimidine nucleosides were prepared from these glycosyl intermediates. PMID:6835838

  4. Effects of Piecewise Spatial Smoothing in 4-D SPECT Reconstruction

    NASA Astrophysics Data System (ADS)

    Qi, Wenyuan; Yang, Yongyi; King, Michael A.

    2014-02-01

    In nuclear medicine, cardiac gated SPECT images are known to suffer from significantly increased noise owing to limited data counts. Consequently, spatial (and temporal) smoothing has been indispensable for suppressing the noise artifacts in SPECT reconstruction. However, recently we demonstrated that the benefit of spatial processing in motion-compensated reconstruction of gated SPECT (aka 4-D) could be outweighed by its adverse effects on the myocardium, which included degraded wall motion and perfusion defect detectability. In this work, we investigate whether we can alleviate these adverse effects by exploiting an alternative spatial smoothing prior in 4-D based on image total variation (TV). TV based prior is known to induce piecewise smoothing which can preserve edge features (such as boundaries of the heart wall) in reconstruction. However, it is not clear whether such a property would necessarily be beneficial for improving the accuracy of the myocardium in 4-D reconstruction. In particular, it is unknown whether it would adversely affect the detectability of perfusion defects that are small in size or low in contrast. In our evaluation study, we first use Monte Carlo simulated imaging with 4-D NURBS-based cardiac-torso (NCAT) phantom wherein the ground truth is known for quantitative comparison. We evaluated the accuracy of the reconstructed myocardium using a number of metrics, including regional and overall accuracy of the myocardium, accuracy of the phase activity curve (PAC) of the LV wall for wall motion, uniformity and spatial resolution of the LV wall, and detectability of perfusion defects using a channelized Hotelling observer (CHO). For lesion detection, we simulated perfusion defects with different sizes and contrast levels with the focus being on perfusion defects that are subtle. As a preliminary demonstration, we also tested on three sets of clinical acquisitions. From the quantitative results, it was demonstrated that TV smoothing could

  5. Non-contact rapid optical coherence elastography by high-speed 4D imaging of elastic waves

    NASA Astrophysics Data System (ADS)

    Song, Shaozhen; Yoon, Soon Joon; Ambroziński, Łukasz; Pelivanov, Ivan; Li, David; Gao, Liang; Shen, Tueng T.; O'Donnell, Matthew; Wang, Ruikang K.

    2017-02-01

    Shear wave OCE (SW-OCE) uses an OCT system to track propagating mechanical waves, providing the information needed to map the elasticity of the target sample. In this study we demonstrate high speed, 4D imaging to capture transient mechanical wave propagation. Using a high-speed Fourier domain mode-locked (FDML) swept-source OCT (SS-OCT) system operating at 1.62 MHz A-line rate, the equivalent volume rate of mechanical wave imaging is 16 kvps (kilo-volumes per second), and total imaging time for a 6 x 6 x 3 mm volume is only 0.32 s. With a displacement sensitivity of 10 nanometers, the proposed 4D imaging technique provides sufficient temporal and spatial resolution for real-time optical coherence elastography (OCE). Combined with a new air-coupled, high-frequency focused ultrasound stimulator requiring no contact or coupling media, this near real-time system can provide quantitative information on localized viscoelastic properties. SW-OCE measurements are demonstrated on tissue-mimicking phantoms and porcine cornea under various intra-ocular pressures. In addition, elasticity anisotropy in the cornea is observed. Images of the mechanical wave group velocity, which correlates with tissue elasticity, show velocities ranging from 4-20 m/s depending on pressure and propagation direction. These initial results strong suggest that 4D imaging for real-time OCE may enable high-resolution quantitative mapping of tissue biomechanical properties in clinical applications.

  6. Arrhythmias after transcatheter closure of perimembranous ventricular septal defects with a modified double-disk occluder: early and long-term results.

    PubMed

    Li, Pan; Zhao, Xian-xian; Zheng, Xing; Qin, Yong-wen

    2012-07-01

    With the development of interventional techniques and devices, transcatheter closure of perimembranous ventricular septal defect has been widely performed. However, there has been a lack of long-term follow-up results about postoperative ECG changes of PmVSD patients. We report our experience of early and late arrhythmias after transcatheter closure of PmVSD with a modified double-disk occluder (MDVO). We performed a retrospective review of 79 patients (47 males, 32 females) between September 2002 and May 2007 who underwent transcatheter closure of perimembranous ventricular septal defect. Symmetric and asymmetric PmVSD occluders were used. The diameter of the evaluated defects ranged from 3 to 12 mm, as measured by TTE and 3 to 15 mm by left ventriculography. Most cases of PmVSD were treated successfully with a single procedure, resulting in a successful closure rate of 97% (77/79 patients). There was no death in any of the patients. After the operation, 79 patients were followed-up for a range of 10-76 months (35.3 ± 17.4 months). In this series, 11 cases of incomplete right bundle branch block and five cases of complete right bundle branch block occurred during the early period after operation. During long-term follow-up, these issues declined in prevalence to five and four cases, respectively. Moreover, reversible third-degree AVB occurred during closure or after the procedure, and two of the three patients with reversible AVB received a temporary heart pacemaker implantation. These patients recovered 1 h, 6 days, and 9 days later, respectively. During 10-76 months of follow-up, no complications occurred in any of the patients, including residual shunt, severe aortic valve, or tricuspid valve regurgitation. Device closure of perimembranous ventricular septal defects with a modified double-disk occluder (MDVO) resulted in excellent closure rates and acceptably low arrhythmia rates.

  7. Spatial correspondence of 4D CT ventilation and SPECT pulmonary perfusion defects in patients with malignant airway stenosis

    NASA Astrophysics Data System (ADS)

    Castillo, Richard; Castillo, Edward; McCurdy, Matthew; Gomez, Daniel R.; Block, Alec M.; Bergsma, Derek; Joy, Sarah; Guerrero, Thomas

    2012-04-01

    To determine the spatial overlap agreement between four-dimensional computed tomography (4D CT) ventilation and single photon emission computed tomography (SPECT) perfusion hypo-functioning pulmonary defect regions in a patient population with malignant airway stenosis. Treatment planning 4D CT images were obtained retrospectively for ten lung cancer patients with radiographically demonstrated airway obstruction due to gross tumor volume. Each patient also received a SPECT perfusion study within one week of the planning 4D CT, and prior to the initiation of treatment. Deformable image registration was used to map corresponding lung tissue elements between the extreme component phase images, from which quantitative three-dimensional (3D) images representing the local pulmonary specific ventilation were constructed. Semi-automated segmentation of the percentile perfusion distribution was performed to identify regional defects distal to the known obstructing lesion. Semi-automated segmentation was similarly performed by multiple observers to delineate corresponding defect regions depicted on 4D CT ventilation. Normalized Dice similarity coefficient (NDSC) indices were determined for each observer between SPECT perfusion and 4D CT ventilation defect regions to assess spatial overlap agreement. Tidal volumes determined from 4D CT ventilation were evaluated versus measurements obtained from lung parenchyma segmentation. Linear regression resulted in a linear fit with slope = 1.01 (R2 = 0.99). Respective values for the average DSC, NDSC1 mm and NDSC2 mm for all cases and multiple observers were 0.78, 0.88 and 0.99, indicating that, on average, spatial overlap agreement between ventilation and perfusion defect regions was comparable to the threshold for agreement within 1-2 mm uncertainty. Corresponding coefficients of variation for all metrics were similarly in the range: 0.10%-19%. This study is the first to quantitatively assess 3D spatial overlap agreement between

  8. Early Feasibility Study of a Transcatheter Tricuspid Valve Annuloplasty: SCOUT Trial 30-Day Results.

    PubMed

    Hahn, Rebecca T; Meduri, Christopher U; Davidson, Charles J; Lim, Scott; Nazif, Tamim M; Ricciardi, Mark J; Rajagopal, Vivek; Ailawadi, Gorav; Vannan, Mani A; Thomas, James D; Fowler, Dale; Rich, Stuart; Martin, Randy; Ong, Geraldine; Groothuis, Adam; Kodali, Susheel

    2017-04-11

    The SCOUT (Percutaneous Tricuspid Valve Annuloplasty System for Symptomatic Chronic Functional Tricuspid Regurgitation) trial is a prospective, single-arm, multicenter, early feasibility study of a novel transcatheter device to plicate the tricuspid annulus (TA) and reduce tricuspid regurgitation (TR). This study tested the feasibility and safety of a novel transcatheter device and assessed its early performance and functional outcomes. Between November 2015 and June 2016, 15 patients with New York Heart Association (NYHA) functional class ≥II and moderate or greater functional TR were enrolled. Primary performance and safety endpoint outcomes were technically successful at 30 days with no reintervention. Echocardiographic measurements (TA diameter, effective regurgitant orifice area [EROA], left ventricular stroke volume [LVSV]) and quality-of-life (QoL) measurements (NYHA functional class, Minnesota Living with Heart Failure Questionnaire [MLHFQ], and 6-min walk test [6MWT]) were performed at baseline and 30 days. All patients (mean 73.2 ± 6.9 years of age, 87% female) underwent successful device implantation with no deaths, strokes, bleeding, tamponade, or valve reintervention. Technical success rate at 30 days was 80%, with 3 single-pledget annular detachments without reintervention. In the remaining 12 patients, there were significant reductions in TA (12.3 ± 3.1 cm 2 to 11.3 ± 2.7 cm 2 , respectively; p = 0.019) and EROA (0.51 ± 0.18 cm 2 vs. 0.32 ± 0.18 cm 2 , respectively; p = 0.020), with significant increase in LVSV (63.6 ± 17.9 ml vs. 71.5 ± 25.7 ml, respectively; p = 0.021). In the intention-to-treat cohort, there were significant improvements in NYHA functional class (≥1 class, p = 0.001), MLHFQ (47.4 ± 17.6 to 20.9 ± 14.8; p < 0.001), and 6MWT (245.2 ± 110.1 to 298.0 m ± 107.6 m; p = 0.008). The 30-day results of the SCOUT trial confirmed the safety of the novel transcatheter device, which reduced TA and EROA, increased LVSV

  9. Transcatheter embolization of renal artery aneurysm in Behçet's disease.

    PubMed

    Planer, D; Verstandig, A; Chajek-Shaul, T

    2001-01-01

    A 20-year-old man with Behçet's disease presented with a ruptured renal artery aneurysm. This patient had previously had aneurysms of the coronary arteries and coronary vein thrombosis that were treated with immunosuppression. A selective transcatheter embolization of the renal artery branch was done successfully and treatment with corticosteroids and methotrexate was added. Presented here is a rare complication of Behçet's disease, with discussion on the pathophysiology, differential diagnosis, and the advantages and disadvantages of the angiographic treatment. This paper is supplemented with a comprehensive review of the literature.

  10. Shadow-driven 4D haptic visualization.

    PubMed

    Zhang, Hui; Hanson, Andrew

    2007-01-01

    Just as we can work with two-dimensional floor plans to communicate 3D architectural design, we can exploit reduced-dimension shadows to manipulate the higher-dimensional objects generating the shadows. In particular, by taking advantage of physically reactive 3D shadow-space controllers, we can transform the task of interacting with 4D objects to a new level of physical reality. We begin with a teaching tool that uses 2D knot diagrams to manipulate the geometry of 3D mathematical knots via their projections; our unique 2D haptic interface allows the user to become familiar with sketching, editing, exploration, and manipulation of 3D knots rendered as projected imageson a 2D shadow space. By combining graphics and collision-sensing haptics, we can enhance the 2D shadow-driven editing protocol to successfully leverage 2D pen-and-paper or blackboard skills. Building on the reduced-dimension 2D editing tool for manipulating 3D shapes, we develop the natural analogy to produce a reduced-dimension 3D tool for manipulating 4D shapes. By physically modeling the correct properties of 4D surfaces, their bending forces, and their collisions in the 3D haptic controller interface, we can support full-featured physical exploration of 4D mathematical objects in a manner that is otherwise far beyond the experience accessible to human beings. As far as we are aware, this paper reports the first interactive system with force-feedback that provides "4D haptic visualization" permitting the user to model and interact with 4D cloth-like objects.

  11. Clinical Relevance of Baseline TCP in Transcatheter Aortic Valve Replacement.

    PubMed

    Sannino, Anna; Stoler, Robert C; Hebeler, Robert F; Szerlip, Molly; Mack, Michael J; Grayburn, Paul A

    2017-10-01

    To investigate the influence of baseline thrombocytopenia (TCP) on short-term and long-term outcomes after transcatheter aortic valve replacement (TAVR). A total of 732 consecutive patients with severe, symptomatic aortic stenosis undergoing TAVR from January 2012 to December 2015 were included. Primary outcomes of interest were the relationship of baseline TCP with 30-day and 1-year all-cause mortality. Secondary outcomes of interest were procedural complications and in-hospital mortality in the same subgroups. The prevalence of TCP (defined as platelet count <150 × 109/L) at baseline was 21.9%, of whom 4.0% had moderate/severe TCP (defined as platelet count <100 × 109/L). Compared to no or mild TCP, moderate/severe TCP at baseline was associated with a significantly higher 30-day mortality (23.3% vs 2.3% and 3.1%, respectively; P<.001) and 1-year mortality (40.0% vs 8.3% and 13.4%, respectively; P<.001). In Cox regression analysis, moderate/severe baseline TCP was an independent predictor of 30-day and 1-year mortality (hazard ratio [HR], 13.18; 95% confidence interval [CI], 4.49-38.64; P<.001 and HR, 5.90; 95% CI, 2.68-13.02; P<.001, respectively). In conclusion, baseline TCP is a strong predictor of mortality in TAVR patients, possibly identifying a specific subgroup of frail patients; therefore, it should be taken into account when addressing TAVR risk.

  12. Outcomes of transcatheter aortic valve replacement using a minimalist approach.

    PubMed

    Gurevich, Sergey; Oestreich, Brett; Kelly, Rosemary F; Mbai, Mackenzie; Bertog, Stefan; Ringsred, Karen; Lawton, Annette; Thooft, Brenda; Wagner, Julie; Garcia, Santiago

    2018-03-01

    Transcatheter Aortic Valve Replacement (TAVR) is increasingly performed using a minimalist approach under monitored anesthesia care (MAC). The safety of this approach remains controversial and adoption has been low in the US. The study cohort was comprised of 130 patients (98% male) who underwent TAVR between 4/2015 and 4/2017 at the Minneapolis VA. We compared the outcomes of 81 patients who underwent TAVR using a standard approach (standard TAVR) and 49 who underwent TAVR using a minimalist approach (minimalist TAVR). Outcome measures included device and procedural success, procedural efficiency, length of intensive care unit (ICU) and hospital stay, procedural complications and hospital readmissions. Mean age was 80 (±9) years and median (IQR) STS score was 5 (4-6). Access included transfemoral (n = 111, 85%) and alternative (n = 19, 15%). Minimalist TAVR was associated with reduced procedural time: median 101 min (IQR: 78-135) versus 127 min (IQR: 97-182, p = 0.03), fluoroscopy time: median 18 min (IQR: 12-26) versus 24 min (IQR: 16-38), p = 0.001), contrast volume 90 ml (IQR: 70-120 ml) versus 140 ml (IQR: 86-213 ml, p < 0.001). A minimalistic approach to TAVR is associated with improved procedural efficiency and reduced length of stay without compromising procedural success or clinical outcomes. Published by Elsevier Inc.

  13. Temporal Trends in Transcatheter Aortic Valve Replacement in France: FRANCE 2 to FRANCE TAVI.

    PubMed

    Auffret, Vincent; Lefevre, Thierry; Van Belle, Eric; Eltchaninoff, Hélène; Iung, Bernard; Koning, René; Motreff, Pascal; Leprince, Pascal; Verhoye, Jean Philippe; Manigold, Thibaut; Souteyrand, Geraud; Boulmier, Dominique; Joly, Patrick; Pinaud, Frédéric; Himbert, Dominique; Collet, Jean Philippe; Rioufol, Gilles; Ghostine, Said; Bar, Olivier; Dibie, Alain; Champagnac, Didier; Leroux, Lionel; Collet, Frédéric; Teiger, Emmanuel; Darremont, Olivier; Folliguet, Thierry; Leclercq, Florence; Lhermusier, Thibault; Olhmann, Patrick; Huret, Bruno; Lorgis, Luc; Drogoul, Laurent; Bertrand, Bernard; Spaulding, Christian; Quilliet, Laurent; Cuisset, Thomas; Delomez, Maxence; Beygui, Farzin; Claudel, Jean-Philippe; Hepp, Alain; Jegou, Arnaud; Gommeaux, Antoine; Mirode, Anfani; Christiaens, Luc; Christophe, Charles; Cassat, Claude; Metz, Damien; Mangin, Lionel; Isaaz, Karl; Jacquemin, Laurent; Guyon, Philippe; Pouillot, Christophe; Makowski, Serge; Bataille, Vincent; Rodés-Cabau, Josep; Gilard, Martine; Le Breton, Hervé

    2017-07-04

    Transcatheter aortic valve replacement (TAVR) is standard therapy for patients with severe aortic stenosis who are at high surgical risk. However, national data regarding procedural characteristics and clinical outcomes over time are limited. The aim of this study was to assess nationwide performance trends and clinical outcomes of TAVR during a 6-year period. TAVRs performed in 48 centers across France between January 2013 and December 2015 were prospectively included in the FRANCE TAVI (French Transcatheter Aortic Valve Implantation) registry. Findings were further compared with those reported from the FRANCE 2 (French Aortic National CoreValve and Edwards 2) registry, which captured all TAVRs performed from January 2010 to January 2012 across 34 centers. A total of 12,804 patients from FRANCE TAVI and 4,165 patients from FRANCE 2 were included in this analysis. The median age of patients was 84.6 years, and 49.7% were men. FRANCE TAVI participants were older but at lower surgical risk (median logistic European System for Cardiac Operative Risk Evaluation [EuroSCORE]: 15.0% vs. 18.4%; p < 0.001). More than 80% of patients in FRANCE TAVI underwent transfemoral TAVR. Transesophageal echocardiography guidance decreased from 60.7% to 32.3% of cases, whereas more recent procedures were increasingly performed in hybrid operating rooms (15.8% vs. 35.7%). Rates of Valve Academic Research Consortium-defined device success increased from 95.3% in FRANCE 2 to 96.8% in FRANCE TAVI (p < 0.001). In-hospital and 30-day mortality rates were 4.4% and 5.4%, respectively, in FRANCE TAVI compared with 8.2% and 10.1%, respectively, in FRANCE 2 (p < 0.001 for both). Stroke and potentially life-threatening complications, such as annulus rupture or aortic dissection, remained stable over time, whereas rates of cardiac tamponade and pacemaker implantation significantly increased. The FRANCE TAVI registry provided reassuring data regarding trends in TAVR performance in an all

  14. Role of modern 3D echocardiography in valvular heart disease

    PubMed Central

    2014-01-01

    Three-dimensional (3D) echocardiography has been conceived as one of the most promising methods for the diagnosis of valvular heart disease, and recently has become an integral clinical tool thanks to the development of high quality real-time transesophageal echocardiography (TEE). In particular, for mitral valve diseases, this new approach has proven to be the most unique, powerful, and convincing method for understanding the complicated anatomy of the mitral valve and its dynamism. The method has been useful for surgical management, including robotic mitral valve repair. Moreover, this method has become indispensable for nonsurgical mitral procedures such as edge to edge mitral repair and transcatheter closure of paravaluvular leaks. In addition, color Doppler 3D echo has been valuable to identify the location of the regurgitant orifice and the severity of the mitral regurgitation. For aortic and tricuspid valve diseases, this method may not be quite as valuable as for the mitral valve. However, the necessity of 3D echo is recognized for certain situations even for these valves, such as for evaluating the aortic annulus for transcatheter aortic valve implantation. It is now clear that this method, especially with the continued development of real-time 3D TEE technology, will enhance the diagnosis and management of patients with these valvular heart diseases. PMID:25378966

  15. Quantitative 3D analysis of bone in hip osteoarthritis using clinical computed tomography.

    PubMed

    Turmezei, Tom D; Treece, Graham M; Gee, Andrew H; Fotiadou, Anastasia F; Poole, Kenneth E S

    2016-07-01

    To assess the relationship between proximal femoral cortical bone thickness and radiological hip osteoarthritis using quantitative 3D analysis of clinical computed tomography (CT) data. Image analysis was performed on clinical CT imaging data from 203 female volunteers with a technique called cortical bone mapping (CBM). Colour thickness maps were created for each proximal femur. Statistical parametric mapping was performed to identify statistically significant differences in cortical bone thickness that corresponded with the severity of radiological hip osteoarthritis. Kellgren and Lawrence (K&L) grade, minimum joint space width (JSW) and a novel CT-based osteophyte score were also blindly assessed from the CT data. For each increase in K&L grade, cortical thickness increased by up to 25 % in distinct areas of the superolateral femoral head-neck junction and superior subchondral bone plate. For increasing severity of CT osteophytes, the increase in cortical thickness was more circumferential, involving a wider portion of the head-neck junction, with up to a 7 % increase in cortical thickness per increment in score. Results were not significant for minimum JSW. These findings indicate that quantitative 3D analysis of the proximal femur can identify changes in cortical bone thickness relevant to structural hip osteoarthritis. • CT is being increasingly used to assess bony involvement in osteoarthritis • CBM provides accurate and reliable quantitative analysis of cortical bone thickness • Cortical bone is thicker at the superior femoral head-neck with worse osteoarthritis • Regions of increased thickness co-locate with impingement and osteophyte formation • Quantitative 3D bone analysis could enable clinical disease prediction and therapy development.

  16. Cerebral Lipiodol Embolism: A Complication of Transcatheter Arterial Chemoembolization for Hepatocellular Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matsumoto, Koichi, E-mail: matsumk2@cc.saga-u.ac.jp; Nojiri, Junichi; Takase, Yukinori

    2007-06-15

    We report a case of cerebral lipiodol embolism following transcatheter chemoembolization (TACE) for hepatocellular carcinoma. A 70-year-old woman with a large unresectable hepatocellular carcinoma underwent TACE. Her level of consciousness deteriorated after the procedure, and magnetic resonance imaging and non-contrast computed tomography revealed a cerebral lipiodol embolism. Despite intensive care, the patient died 2 weeks later. The complication might have been due to systemic-pulmonary shunts caused by previous surgeries and/or direct invasion of the recurrent tumor.

  17. Digit ratio (2D:4D) and postoperative pain perception.

    PubMed

    Kasielska-Trojan, Anna; Stabryła, Piotr; Antoszewski, Bogusław

    2017-07-01

    It has not been established whether sex differences in pain perception are influenced by prenatal sex hormones. Digit ratio as an indicator of prenatal hormone exposure can be used as a simple measure of the influence of prenatal hormones on pain sensitivity or perception in adulthood. The aim of this study was to determine a correlation between the 2D:4D ratio and pain perception in the postoperative period after rhinoplasty. A prospective cohort study of 100 patients (50 women of the mean age of 30.74±8.09years and 50 men of the mean age of 30.98±10.86years) who underwent posttraumatic rhinoplasty due to the nose trauma in Plastic, Reconstructive and Aesthetic Surgery Clinic. The following measurements were taken the day before a surgery: body height, waist and hip circumference, II and IV digits' lengths and body weight. All subjects filled in a questionnaire including 0-10-point VAS scales to assess postoperative pain 1h after an operation (AO), 6h AO, 12h AO, 24h AO and 48h AO. Women with low 2D:4D reported significantly more pain 1h after an operation than women with high 2D:4D. Similar correlation was observed for low 2D:4D in women 48h AO. In men, low 2D:4D was associated with lower postoperative pain 12h AO (p=0.029). In conclusion, we showed that low 2D:4D in women was associated with high postoperative pain, and low right 2D:4D in men was associated with low postoperative pain. This may suggest that intrauterine estrogen exposure makes women more resistant to pain. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Transcatheter Embolization of a Coronary Fistula Originating from the Left Anterior Descending Artery by Using N-Butyl 2-Cyanoacrylate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karagoz, Tevfik; Celiker, Alpay; Cil, Barbaros

    In this report, we describe a successful percutaneous transcatheter n-butyl 2-cyanoacrylate embolization of a coronary fistula originating from the left anterior descending artery in an adolescent with unexpected recurrent attacks of myocardial ischemia.

  19. [Transcatheter aortic valve replacement].

    PubMed

    Sawa, Yoshiki

    2014-07-01

    While transcatheter aortic valve replacement( TAVR) has spread rapidly all over the world for highrisk patients with severe aortic stenosis (AS), SAPIEN XT was approved in Japan in October 2013. Since that, approximately 400 TAVR cases were performed in Japan. In our institute, we have performed 164 cases since first case in Japan in 2009 and have achieved satisfactory early results(30-day mortality:1.2%). At the same time, however, simultaneously various TAVR-related complications including a paravalvular leak, stroke, vascular complications, and coronary obstruction were observed. A reduction in the incidence and severity of these complications had led technical improvements in various new devices(2nd generation TAVR device such as the SAPIEN 3, ACURATE, and JenaValve) and in implantation techniques including repositioning/recapturing features, paravalvular sealing technologies, and prevention of coronary obstruction. Furthermore, there is also increasing experience with special indications for TAVR such as pure aortic valve insufficiency or valve-in-valve techniques. Currently, an increasing number of publications of midterm results demonstrate good prosthetic valve function and durability, with good quality of life and low morbidity after TAVR. There are also some randomized trials such as PARTNER 2 or SURTAVI to investigate potential benefits of TAVR for intermediate-risk patients. These improvements in the TAVR devices promises the expansion of TAVR towards the treatment of lower-risk patients in the near future.

  20. Breast tumour visualization using 3D quantitative ultrasound methods

    NASA Astrophysics Data System (ADS)

    Gangeh, Mehrdad J.; Raheem, Abdul; Tadayyon, Hadi; Liu, Simon; Hadizad, Farnoosh; Czarnota, Gregory J.

    2016-04-01

    Breast cancer is one of the most common cancer types accounting for 29% of all cancer cases. Early detection and treatment has a crucial impact on improving the survival of affected patients. Ultrasound (US) is non-ionizing, portable, inexpensive, and real-time imaging modality for screening and quantifying breast cancer. Due to these attractive attributes, the last decade has witnessed many studies on using quantitative ultrasound (QUS) methods in tissue characterization. However, these studies have mainly been limited to 2-D QUS methods using hand-held US (HHUS) scanners. With the availability of automated breast ultrasound (ABUS) technology, this study is the first to develop 3-D QUS methods for the ABUS visualization of breast tumours. Using an ABUS system, unlike the manual 2-D HHUS device, the whole patient's breast was scanned in an automated manner. The acquired frames were subsequently examined and a region of interest (ROI) was selected in each frame where tumour was identified. Standard 2-D QUS methods were used to compute spectral and backscatter coefficient (BSC) parametric maps on the selected ROIs. Next, the computed 2-D parameters were mapped to a Cartesian 3-D space, interpolated, and rendered to provide a transparent color-coded visualization of the entire breast tumour. Such 3-D visualization can potentially be used for further analysis of the breast tumours in terms of their size and extension. Moreover, the 3-D volumetric scans can be used for tissue characterization and the categorization of breast tumours as benign or malignant by quantifying the computed parametric maps over the whole tumour volume.

  1. Cost-effectiveness considerations in transcatheter management of valvular heart disease.

    PubMed

    Gadey, Gautam; Reynolds, Matthew R

    2014-09-01

    In 2011, health care spending in Canada accounted for 11.2% of gross domestic product. Increased life expectancy, combined with the fact that new medical technologies generally tend to improve clinical results at an increased cost, are leading developed nations to devote rising amounts of financial resources to health care. Valvular heart disease is an example of an age-related health problem with rising prevalence that has recently seen an emergence of new catheter-based technologies, which are rapidly changing the treatment landscape. This article reviews the current literature on the health economics of catheter-based valve therapies. Transcatheter aortic valve replacement (TAVR), a less invasive approach to valve replacement, is currently approved in the United States, Canada, and Europe for 2 groups of patients: those with symptomatic severe aortic stenosis who are unsuitable for surgery and those who are suitable but are at high risk for surgery. TAVR, when compared with medical therapy, results in significant improvement in survival for inoperable patients, with incremental costs that are generally considered to be acceptable in most western nations. However, in high-risk surgical candidates, TAVR has shown similar survival rates when compared with surgical aortic valve replacement, with only short-term advantages in quality of life. Cost-effectiveness ratios in this population have varied widely based on differing estimates of incremental costs. Information regarding the health economics of transcatheter mitral valve therapies is still quite preliminary and limited to the MitraClip (Abbott Laboratories, Abbott Park, IL). Ongoing trials should provide additional information about the health economics of this new technology. Copyright © 2014 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  2. Speleogenesis, geometry, and topology of caves: A quantitative study of 3D karst conduits

    NASA Astrophysics Data System (ADS)

    Jouves, Johan; Viseur, Sophie; Arfib, Bruno; Baudement, Cécile; Camus, Hubert; Collon, Pauline; Guglielmi, Yves

    2017-12-01

    Karst systems are hierarchically spatially organized three-dimensional (3D) networks of conduits behaving as drains for groundwater flow. Recently, geostatistical approaches proposed to generate karst networks from data and parameters stemming from analogous observed karst features. Other studies have qualitatively highlighted relationships between speleogenetic processes and cave patterns. However, few studies have been performed to quantitatively define these relationships. This paper reports a quantitative study of cave geometries and topologies that takes the underlying speleogenetic processes into account. In order to study the spatial organization of caves, a 3D numerical database was built from 26 caves, corresponding to 621 km of cumulative cave passages representative of the variety of karst network patterns. The database includes 3D speleological surveys for which the speleogenetic context is known, allowing the polygenic karst networks to be divided into 48 monogenic cave samples and classified into four cave patterns: vadose branchwork (VB), water-table cave (WTC), looping cave (LC), and angular maze (AM). Eight morphometric cave descriptors were calculated, four geometrical parameters (width-height ratio, tortuosity, curvature, and vertical index) and four topological ones (degree of node connectivity, α and γ graph indices, and ramification index) respectively. The results were validated by statistical analyses (Kruskal-Wallis test and PCA). The VB patterns are clearly distinct from AM ones and from a third group including WTC and LC. A quantitative database of cave morphology characteristics is provided, depending on their speleogenetic processes. These characteristics can be used to constrain and/or validate 3D geostatistical simulations. This study shows how important it is to relate the geometry and connectivity of cave networks to recharge and flow processes. Conversely, the approach developed here provides proxies to estimate the evolution of

  3. WE-AB-BRA-07: Quantitative Evaluation of 2D-2D and 2D-3D Image Guided Radiation Therapy for Clinical Trial Credentialing, NRG Oncology/RTOG

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giaddui, T; Yu, J; Xiao, Y

    Purpose: 2D-2D kV image guided radiation therapy (IGRT) credentialing evaluation for clinical trial qualification was historically qualitative through submitting screen captures of the fusion process. However, as quantitative DICOM 2D-2D and 2D-3D image registration tools are implemented in clinical practice for better precision, especially in centers that treat patients with protons, better IGRT credentialing techniques are needed. The aim of this work is to establish methodologies for quantitatively reviewing IGRT submissions based on DICOM 2D-2D and 2D-3D image registration and to test the methodologies in reviewing 2D-2D and 2D-3D IGRT submissions for RTOG/NRG Oncology clinical trials qualifications. Methods: DICOM 2D-2Dmore » and 2D-3D automated and manual image registration have been tested using the Harmony tool in MIM software. 2D kV orthogonal portal images are fused with the reference digital reconstructed radiographs (DRR) in the 2D-2D registration while the 2D portal images are fused with DICOM planning CT image in the 2D-3D registration. The Harmony tool allows alignment of the two images used in the registration process and also calculates the required shifts. Shifts calculated using MIM are compared with those submitted by institutions for IGRT credentialing. Reported shifts are considered to be acceptable if differences are less than 3mm. Results: Several tests have been performed on the 2D-2D and 2D-3D registration. The results indicated good agreement between submitted and calculated shifts. A workflow for reviewing these IGRT submissions has been developed and will eventually be used to review IGRT submissions. Conclusion: The IROC Philadelphia RTQA center has developed and tested a new workflow for reviewing DICOM 2D-2D and 2D-3D IGRT credentialing submissions made by different cancer clinical centers, especially proton centers. NRG Center for Innovation in Radiation Oncology (CIRO) and IROC RTQA center continue their collaborative efforts to

  4. Three-dimensional prototyping for procedural simulation of transcatheter mitral valve replacement in patients with mitral annular calcification.

    PubMed

    El Sabbagh, Abdallah; Eleid, Mackram F; Matsumoto, Jane M; Anavekar, Nandan S; Al-Hijji, Mohammed A; Said, Sameh M; Nkomo, Vuyisile T; Holmes, David R; Rihal, Charanjit S; Foley, Thomas A

    2018-01-23

    Three-dimensional (3D) prototyping is a novel technology which can be used to plan and guide complex procedures such as transcatheter mitral valve replacement (TMVR). Eight patients with severe mitral annular calcification (MAC) underwent TMVR. 3D digital models with digital balloon expandable valves were created from pre-procedure CT scans using dedicated software. Five models were printed. These models were used to assess prosthesis sizing, anchoring, expansion, paravalvular gaps, left ventricular outflow tract (LVOT) obstruction, and other potential procedure pitfalls. Results of 3D prototyping were then compared to post procedural imaging to determine how closely the achieved procedural result mirrored the 3D modeled result. 3D prototyping simulated LVOT obstruction in one patient who developed it and in another patient who underwent alcohol septal ablation prior to TMVR. Valve sizing correlated with actual placed valve size in six out of the eight patients and more than mild paravalvular leak (PVL) was simulated in two of the three patients who had it. Patients who had mismatch between their modeled valve size and post-procedural imaging were the ones that had anterior leaflet resection which could have altered valve sizing and PVL simulation. 3D printed model of one of the latter patients allowed modification of anterior leaflet to simulate surgical resection and was able to estimate the size and location of the PVL after inserting a valve stent into the physical model. 3D prototyping in TMVR for severe MAC is feasible for simulating valve sizing, apposition, expansion, PVL, and LVOT obstruction. © 2018 Wiley Periodicals, Inc.

  5. 4D cone-beam CT reconstruction using multi-organ meshes for sliding motion modeling

    NASA Astrophysics Data System (ADS)

    Zhong, Zichun; Gu, Xuejun; Mao, Weihua; Wang, Jing

    2016-02-01

    A simultaneous motion estimation and image reconstruction (SMEIR) strategy was proposed for 4D cone-beam CT (4D-CBCT) reconstruction and showed excellent results in both phantom and lung cancer patient studies. In the original SMEIR algorithm, the deformation vector field (DVF) was defined on voxel grid and estimated by enforcing a global smoothness regularization term on the motion fields. The objective of this work is to improve the computation efficiency and motion estimation accuracy of SMEIR for 4D-CBCT through developing a multi-organ meshing model. Feature-based adaptive meshes were generated to reduce the number of unknowns in the DVF estimation and accurately capture the organ shapes and motion. Additionally, the discontinuity in the motion fields between different organs during respiration was explicitly considered in the multi-organ mesh model. This will help with the accurate visualization and motion estimation of the tumor on the organ boundaries in 4D-CBCT. To further improve the computational efficiency, a GPU-based parallel implementation was designed. The performance of the proposed algorithm was evaluated on a synthetic sliding motion phantom, a 4D NCAT phantom, and four lung cancer patients. The proposed multi-organ mesh based strategy outperformed the conventional Feldkamp-Davis-Kress, iterative total variation minimization, original SMEIR and single meshing method based on both qualitative and quantitative evaluations.

  6. 4D cone-beam CT reconstruction using multi-organ meshes for sliding motion modeling.

    PubMed

    Zhong, Zichun; Gu, Xuejun; Mao, Weihua; Wang, Jing

    2016-02-07

    A simultaneous motion estimation and image reconstruction (SMEIR) strategy was proposed for 4D cone-beam CT (4D-CBCT) reconstruction and showed excellent results in both phantom and lung cancer patient studies. In the original SMEIR algorithm, the deformation vector field (DVF) was defined on voxel grid and estimated by enforcing a global smoothness regularization term on the motion fields. The objective of this work is to improve the computation efficiency and motion estimation accuracy of SMEIR for 4D-CBCT through developing a multi-organ meshing model. Feature-based adaptive meshes were generated to reduce the number of unknowns in the DVF estimation and accurately capture the organ shapes and motion. Additionally, the discontinuity in the motion fields between different organs during respiration was explicitly considered in the multi-organ mesh model. This will help with the accurate visualization and motion estimation of the tumor on the organ boundaries in 4D-CBCT. To further improve the computational efficiency, a GPU-based parallel implementation was designed. The performance of the proposed algorithm was evaluated on a synthetic sliding motion phantom, a 4D NCAT phantom, and four lung cancer patients. The proposed multi-organ mesh based strategy outperformed the conventional Feldkamp-Davis-Kress, iterative total variation minimization, original SMEIR and single meshing method based on both qualitative and quantitative evaluations.

  7. 4D cone-beam CT reconstruction using multi-organ meshes for sliding motion modeling

    PubMed Central

    Zhong, Zichun; Gu, Xuejun; Mao, Weihua; Wang, Jing

    2016-01-01

    A simultaneous motion estimation and image reconstruction (SMEIR) strategy was proposed for 4D cone-beam CT (4D-CBCT) reconstruction and showed excellent results in both phantom and lung cancer patient studies. In the original SMEIR algorithm, the deformation vector field (DVF) was defined on voxel grid and estimated by enforcing a global smoothness regularization term on the motion fields. The objective of this work is to improve the computation efficiency and motion estimation accuracy of SMEIR for 4D-CBCT through developing a multi-organ meshing model. Feature-based adaptive meshes were generated to reduce the number of unknowns in the DVF estimation and accurately capture the organ shapes and motion. Additionally, the discontinuity in the motion fields between different organs during respiration was explicitly considered in the multi-organ mesh model. This will help with the accurate visualization and motion estimation of the tumor on the organ boundaries in 4D-CBCT. To further improve the computational efficiency, a GPU-based parallel implementation was designed. The performance of the proposed algorithm was evaluated on a synthetic sliding motion phantom, a 4D NCAT phantom, and four lung cancer patients. The proposed multi-organ mesh based strategy outperformed the conventional Feldkamp–Davis–Kress, iterative total variation minimization, original SMEIR and single meshing method based on both qualitative and quantitative evaluations. PMID:26758496

  8. Transcatheter treatment of tricuspid regurgitation by caval valve implantation--experimental evaluation of decellularized tissue valves in central venous position.

    PubMed

    Lauten, Alexander; Laube, Adrian; Schubert, Harald; Bischoff, Sabine; Nietzsche, Sandor; Horstkötter, Kim; Poudel-Bochmann, Bhawana; Franz, Marcus; Lichtenberg, Artur; Figulla, Hans R; Akhyari, Payam

    2015-01-01

    Caval valve implantation has been suggested for transcatheter treatment of severe tricuspid regurgitation (TR). Combining the interventional technique with the promising surgical experience with decellularized valves, we sought to evaluate the functional and structural outcome of decellularized pericardial tissue valves (dTVs) in the low-pressure venous circulation in a chronic model of TR. Sixteen pericardial tissue valves were heterotopically implanted in the inferior and superior vena cava in a sheep model (54-98 kg; median 74.5 kg, n = 8) of severe TR. The devices were assembled using self-expanding nitinol stents and bovine pericardia decellularized by a detergent-based protocol (group dTV; n = 8). Glutaraldehyde-fixed pericardial tissue valves served as control (GaTV, n = 8). After 6 months, device function and structural maturation were analyzed using echocardiographic, histologic, immunohistologic, and electron microscopic approaches. After implantation, cardiac output increased significantly from 3.7 ± 1.1 l/min to 4.8 ± 1.1 l/min (P < 0.05) and competent valve function was verified by angiography. At 6 months, angiographic and echocardiographic evaluation revealed moderate to severe regurgitation in all GaTV. In contrast, five of the eight dTVs functioned well with only minor regurgitation. In these animals, autopsy revealed preserved valve structure with tender leaflets without signs of thrombosis or calcification. Conversely, GaTV showed severe degeneration with large calcification areas. Microscopic and histologic analysis confirmed endothelial repopulation in both valve types. However, additional interstitial reseeding was observed in decellularized valves. In the venous circulation in severe TR, decellularized valves show superior functional performance compared to Ga-fixed tissue valves. Macroscopic and microscopic analyses suggest preserved structural integrity and advanced endothelial and interstitial repopulation with

  9. Isoguanine quartets formed by d(T4isoG4T4): tetraplex identification and stability.

    PubMed Central

    Seela, F; Wei, C; Melenewski, A

    1996-01-01

    The self-aggregation of the oligonucleotide d(T4isoG4T4) (1) is investigated. Based on ion exchange HPLC experiments and CD spectroscopy, a tetrameric structure is identified. This structure was formed in the presence of sodium ions and shows almost the same chromatographic mobility on ion exchange HPLC as d(T4G4T4) (2). The ratio of aggregate versus monomer is temperature dependent and the tetraplex of [d(T4isoG4T4)]4 is more stable than that of [d(T4G4T4)]4. A mixture of d(T4isoG4T4) and d(T4G4T4) forms mixed tetraplexes containing strands of d(T4isoG4T4) and d(T4G4T4). PMID:9016664

  10. 3D quantitative analysis of early decomposition changes of the human face.

    PubMed

    Caplova, Zuzana; Gibelli, Daniele Maria; Poppa, Pasquale; Cummaudo, Marco; Obertova, Zuzana; Sforza, Chiarella; Cattaneo, Cristina

    2018-03-01

    Decomposition of the human body and human face is influenced, among other things, by environmental conditions. The early decomposition changes that modify the appearance of the face may hamper the recognition and identification of the deceased. Quantitative assessment of those changes may provide important information for forensic identification. This report presents a pilot 3D quantitative approach of tracking early decomposition changes of a single cadaver in controlled environmental conditions by summarizing the change with weekly morphological descriptions. The root mean square (RMS) value was used to evaluate the changes of the face after death. The results showed a high correlation (r = 0.863) between the measured RMS and the time since death. RMS values of each scan are presented, as well as the average weekly RMS values. The quantification of decomposition changes could improve the accuracy of antemortem facial approximation and potentially could allow the direct comparisons of antemortem and postmortem 3D scans.

  11. 4D electron tomography.

    PubMed

    Kwon, Oh-Hoon; Zewail, Ahmed H

    2010-06-25

    Electron tomography provides three-dimensional (3D) imaging of noncrystalline and crystalline equilibrium structures, as well as elemental volume composition, of materials and biological specimens, including those of viruses and cells. We report the development of 4D electron tomography by integrating the fourth dimension (time resolution) with the 3D spatial resolution obtained from a complete tilt series of 2D projections of an object. The different time frames of tomograms constitute a movie of the object in motion, thus enabling studies of nonequilibrium structures and transient processes. The method was demonstrated using carbon nanotubes of a bracelet-like ring structure for which 4D tomograms display different modes of motion, such as breathing and wiggling, with resonance frequencies up to 30 megahertz. Applications can now make use of the full space-time range with the nanometer-femtosecond resolution of ultrafast electron tomography.

  12. 4D Electron Tomography

    NASA Astrophysics Data System (ADS)

    Kwon, Oh-Hoon; Zewail, Ahmed H.

    2010-06-01

    Electron tomography provides three-dimensional (3D) imaging of noncrystalline and crystalline equilibrium structures, as well as elemental volume composition, of materials and biological specimens, including those of viruses and cells. We report the development of 4D electron tomography by integrating the fourth dimension (time resolution) with the 3D spatial resolution obtained from a complete tilt series of 2D projections of an object. The different time frames of tomograms constitute a movie of the object in motion, thus enabling studies of nonequilibrium structures and transient processes. The method was demonstrated using carbon nanotubes of a bracelet-like ring structure for which 4D tomograms display different modes of motion, such as breathing and wiggling, with resonance frequencies up to 30 megahertz. Applications can now make use of the full space-time range with the nanometer-femtosecond resolution of ultrafast electron tomography.

  13. 4-D OCT in Developmental Cardiology

    NASA Astrophysics Data System (ADS)

    Jenkins, Michael W.; Rollins, Andrew M.

    Although strong evidence exists to suggest that altered cardiac function can lead to CHDs, few studies have investigated the influential role of cardiac function and biophysical forces on the development of the cardiovascular system due to a lack of proper in vivo imaging tools. 4-D imaging is needed to decipher the complex spatial and temporal patterns of biomechanical forces acting upon the heart. Numerous solutions over the past several years have demonstrated 4-D OCT imaging of the developing cardiovascular system. This chapter will focus on these solutions and explain their context in the evolution of 4-D OCT imaging. The first sections describe the relevant techniques (prospective gating, direct 4-D imaging, retrospective gating), while later sections focus on 4-D Doppler imaging and measurements of force implementing 4-D OCT Doppler. Finally, the techniques are summarized, and some possible future directions are discussed.

  14. Modeling respiratory motion for reducing motion artifacts in 4D CT images.

    PubMed

    Zhang, Yongbin; Yang, Jinzhong; Zhang, Lifei; Court, Laurence E; Balter, Peter A; Dong, Lei

    2013-04-01

    Four-dimensional computed tomography (4D CT) images have been recently adopted in radiation treatment planning for thoracic and abdominal cancers to explicitly define respiratory motion and anatomy deformation. However, significant image distortions (artifacts) exist in 4D CT images that may affect accurate tumor delineation and the shape representation of normal anatomy. In this study, the authors present a patient-specific respiratory motion model, based on principal component analysis (PCA) of motion vectors obtained from deformable image registration, with the main goal of reducing image artifacts caused by irregular motion during 4D CT acquisition. For a 4D CT image set of a specific patient, the authors calculated displacement vector fields relative to a reference phase, using an in-house deformable image registration method. The authors then used PCA to decompose each of the displacement vector fields into linear combinations of principal motion bases. The authors have demonstrated that the regular respiratory motion of a patient can be accurately represented by a subspace spanned by three principal motion bases and their projections. These projections were parameterized using a spline model to allow the reconstruction of the displacement vector fields at any given phase in a respiratory cycle. Finally, the displacement vector fields were used to deform the reference CT image to synthesize CT images at the selected phase with much reduced image artifacts. The authors evaluated the performance of the in-house deformable image registration method using benchmark datasets consisting of ten 4D CT sets annotated with 300 landmark pairs that were approved by physicians. The initial large discrepancies across the landmark pairs were significantly reduced after deformable registration, and the accuracy was similar to or better than that reported by state-of-the-art methods. The proposed motion model was quantitatively validated on 4D CT images of a phantom and a

  15. Quantitative analyses of the 3D nuclear landscape recorded with super-resolved fluorescence microscopy.

    PubMed

    Schmid, Volker J; Cremer, Marion; Cremer, Thomas

    2017-07-01

    Recent advancements of super-resolved fluorescence microscopy have revolutionized microscopic studies of cells, including the exceedingly complex structural organization of cell nuclei in space and time. In this paper we describe and discuss tools for (semi-) automated, quantitative 3D analyses of the spatial nuclear organization. These tools allow the quantitative assessment of highly resolved different chromatin compaction levels in individual cell nuclei, which reflect functionally different regions or sub-compartments of the 3D nuclear landscape, and measurements of absolute distances between sites of different chromatin compaction. In addition, these tools allow 3D mapping of specific DNA/RNA sequences and nuclear proteins relative to the 3D chromatin compaction maps and comparisons of multiple cell nuclei. The tools are available in the free and open source R packages nucim and bioimagetools. We discuss the use of masks for the segmentation of nuclei and the use of DNA stains, such as DAPI, as a proxy for local differences in chromatin compaction. We further discuss the limitations of 3D maps of the nuclear landscape as well as problems of the biological interpretation of such data. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Short- and Medium-Term Outcomes After Transcatheter Pulmonary Valve Placement in the Expanded Multicenter US Melody Valve Trial

    PubMed Central

    McElhinney, Doff B.; Hellenbrand, William E.; Zahn, Evan M.; Jones, Thomas K.; Cheatham, John P.; Lock, James E.; Vincent, Julie A.

    2014-01-01

    Background Transcatheter pulmonary valve placement is an emerging therapy for pulmonary regurgitation and right ventricular outflow tract obstruction in selected patients. The Melody valve was recently approved in the United States for placement in dysfunctional right ventricular outflow tract conduits. Methods and Results From January 2007 to August 2009, 136 patients (median age, 19 years) underwent catheterization for intended Melody valve implantation at 5 centers. Implantation was attempted in 124 patients; in the other 12, transcatheter pulmonary valve placement was not attempted because of the risk of coronary artery compression (n=6) or other clinical or protocol contraindications. There was 1 death from intracranial hemorrhage after coronary artery dissection, and 1 valve was explanted after conduit rupture. The median peak right ventricular outflow tract gradient was 37 mm Hg before implantation and 12 mm Hg immediately after implantation. Before implantation, pulmonary regurgitation was moderate or severe in 92 patients (81% with data); no patient had more than mild pulmonary regurgitation early after implantation or during follow-up (≥1 year in 65 patients). Freedom from diagnosis of stent fracture was 77.8±4.3% at 14 months. Freedom from Melody valve dysfunction or reintervention was 93.5±2.4% at 1 year. A higher right ventricular outflow tract gradient at discharge (P=0.003) and younger age (P=0.01) were associated with shorter freedom from dysfunction. Conclusions In this updated report from the multicenter US Melody valve trial, we demonstrated an ongoing high rate of procedural success and encouraging short-term valve function. All reinterventions in this series were for right ventricular outflow tract obstruction, highlighting the importance of patient selection, adequate relief of obstruction, and measures to prevent and manage stent fracture. Clinical Trial Registration URL: http://www.clinicaltrials.gov. Unique identifier: NCT00740870. PMID

  17. Complete filter-based cerebral embolic protection with transcatheter aortic valve replacement.

    PubMed

    Van Gils, Lennart; Kroon, Herbert; Daemen, Joost; Ren, Claire; Maugenest, Anne-Marie; Schipper, Marguerite; De Jaegere, Peter P; Van Mieghem, Nicolas M

    2018-03-01

    To evaluate the value of left vertebral artery filter protection in addition to the current filter-based embolic protection technology to achieve complete cerebral protection during TAVR. The occurrence of cerebrovascular events after transcatheter aortic valve replacement (TAVR) has fueled concern for its potential application in younger patients with longer life expectancy. Transcatheter cerebral embolic protection (TCEP) devices may limit periprocedural cerebrovascular events by preventing macro and micro-embolization to the brain. Conventional filter-based TCEP devices cover three extracranial contributories to the brain, yet leave the left vertebral artery unprotected. Patients underwent TAVR with complete TCEP. A dual-filter system was deployed in the brachiocephalic trunk and left common carotid artery with an additional single filter in the left vertebral artery. After TAVR all filters were retrieved and sent for histopathological evaluation by an experienced pathologist. Eleven patients received a dual-filter system and nine of them received an additional left vertebral filter. In the remaining two patients, the left vertebral filter could not be deployed. No periprocedural strokes occurred. We found debris in all filters, consisting of thrombus, tissue derived debris, and foreign body material. The left vertebral filter contained debris in an equal amount of patients as the Sentinel filters. The size of the captured particles was similar between all filters. The left vertebral artery is an important entry route for embolic material to the brain during TAVR. Selective filter protection of the left vertebral artery revealed embolic debris in all patients. The clinical value of complete filter-based TCEP during TAVR warrants further research. © 2017 Wiley Periodicals, Inc.

  18. Dopamine D4 receptor, but not the ADHD-associated D4.7 variant, forms functional heteromers with the dopamine D2S receptor in the brain

    PubMed Central

    González, Sergio; Rangel-Barajas, Claudia; Peper, Marcela; Lorenzo, Ramiro; Moreno, Estefanía; Ciruela, Francisco; Borycz, Janusz; Ortiz, Jordi; Lluís, Carme; Franco, Rafael; McCormick, Peter J.; Volkow, Nora D.; Rubinstein, Marcelo; Floran, Benjamin; Ferré, Sergi

    2011-01-01

    Polymorphic variants of the dopamine D4 receptor have been consistently associated with attention-deficit hyperactivity disorder (ADHD). However the functional significance of the risk polymorphism (variable number of tandem repeats in exon 3) is still unclear. Here we show that whereas the most frequent 4-repeat (D4.4) and the 2-repeat (D4.2) variants form functional heteromers with the short isoform of the dopamine D2 receptor (D2S), the 7-repeat risk allele (D4.7) does not. D2 receptor activation in the D2S-D4 receptor heteromer potentiates D4 receptor-mediated MAPK signaling in transfected cells and in the striatum, which did not occur in cells expressing D4.7 or in the striatum of knock-in mutant mice carrying the 7 repeats of the human D4.7 in the third intracellular loop of the D4 receptor. In the striatum D4 receptors are localized in cortico-striatal glutamatergic terminals, where they selectively modulate glutamatergic neurotransmission by interacting with D2S receptors. This interaction shows the same qualitative characteristics than the D2S-D4 receptor heteromer-mediated MAPK signaling and D2S receptor activation potentiates D4 receptor-mediated inibition of striatal glutamate release. It is therefore postulated that dysfunctional D2S-D4.7 heteromers may impair presynaptic dopaminergic control of corticostriatal glutamatergic neurotransmission and explain functional deficits associated with ADHD. PMID:21844870

  19. Early and mid-term outcomes of 1904 patients undergoing transcatheter balloon-expandable valve implantation in Italy: results from the Italian Transcatheter Balloon-Expandable Valve Implantation Registry (ITER).

    PubMed

    Salizzoni, Stefano; D'Onofrio, Augusto; Agrifoglio, Marco; Colombo, Antonio; Chieffo, Alaide; Cioni, Micaela; Besola, Laura; Regesta, Tommaso; Rapetto, Filippo; Tarantini, Giuseppe; Napodano, Massimo; Gabbieri, Davide; Saia, Francesco; Tamburino, Corrado; Ribichini, Flavio; Cugola, Diego; Aiello, Marco; Sanna, Francesco; Iadanza, Alessandro; Pompei, Esmeralda; Stefàno, Pierluigi; Cappai, Antioco; Minati, Alessandro; Cassese, Mauro; Martinelli, Gian Luca; Agostinelli, Andrea; Fiorilli, Rosario; Casilli, Francesco; Reale, Maurizio; Bedogni, Francesco; Petronio, Anna Sonia; Mozzillo, Rosa Alba; Bonmassari, Roberto; Briguori, Carlo; Liso, Armando; Sardella, Gennaro; Bruschi, Giuseppe; Fiorina, Claudia; Filippini, Claudia; Moretti, Claudio; D'Amico, Maurizio; La Torre, Michele; Conrotto, Federico; Di Bartolomeo, Roberto; Gerosa, Gino; Rinaldi, Mauro

    2016-12-01

    The aim of this multicentre study is to report the clinical experiences of all patients undergoing transcatheter aortic valve implantation (TAVI) with a balloon-expandable device in Italy. The Italian Transcatheter balloon-Expandable valve Registry (ITER) is a real-world registry that includes patients who have undergone TAVI with the Sapien (Edwards Lifesciences, Irvine, CA, USA) bioprosthesis in Italy since it became available in clinical practice. From 2007 to 2012, 1904 patients were enrolled to undergo TAVI in 33 Italian centres. Outcomes were classified according to the updated Valve Academic Research Consortium (VARC-2) definitions. A multivariable analysis was performed to identify independent predictors of all-cause mortality. Mean age was 81.7 (SD:6.2) years, and 1147 (60.2%) patients were female. Mean Logistic EuroSCORE was 21.1% (SD:13.7). Transfemoral, transapical, transaortic and transaxillary TAVI was performed in 1252 (65.8%), 630 (33.1%), 18 (0.9%) and 4 (0.2%) patients, respectively. Operative mortality was 7.2% (137 patients). The VARC-2 outcomes were as follows: device success, 88.1%; disabling stroke, 1.0%; life-threatening and major bleeding 9.8 and 10.5%, respectively; major vascular complication, 9.7%; acute kidney injury, 8.2%; acute myocardial infarction ≤72 h, 1.5%. Perioperative pacemaker implantation was necessary in 116 (6.1%) patients. At discharge, the mean transprosthetic gradient was 10.7 (SD:4.5) mmHg. Incidence of postoperative mild, moderate or severe paravalvular leak was, respectively, 32.1, 5.0 and 0.4%. A total of 444/1767 (25.1%) deaths after hospital discharge were reported: of these, 168 (37.8%) were classified as cardiac death. Preoperative independent predictors of all-cause mortality were male gender (HR: 1.395; 95% CI:1.052-1.849); overweight, BMI 25-30 kg/m 2 (HR: 0.775; 95% CI: 0.616-0.974); serum creatinine level (every 1 mg/dl increase; HR: 1.314; 95% CI:1.167-1.480); haemoglobin level (every 1 g/dl increase; HR

  20. Transcatheter Retrieval of Embolized Atrial Septal Defect Occluder Device by Waist Capture Technique.

    PubMed

    Her, Ae-Young; Lim, Kyung-Hun; Shin, Eun-Seok

    2018-01-27

    This case study describes the successful percutaneous transcatheter retrieval of an embolized Amplatzer occluder device using the "waist capture technique" in a patient with an atrial septal defect. This technique allowed for stability of the Amplatzer device, compression of the atrial discs for easier removal, prevention of further embolization, and minimal injury to vasculature during device retrieval. This novel and effective technique can be used safely for the retrieval of Amplatzer devices in the venous system.

  1. Transcatheter Aortic Valve Replacement by a Novel Suprasternal Approach.

    PubMed

    Codner, Pablo; Pugliese, Daniel; Kouz, Rémi; Patel, Amisha; Chen, Cheng-Han; Terre, Juan; Eudailey, Kyle W; Nazif, Tamim; Vahl, Torsten P; George, Isaac; Khalique, Omar K; Hahn, Rebecca T; Leon, Martin B; Kodali, Susheel; Borger, Michael

    2018-04-01

    Transcatheter aortic valve replacement (TAVR) provides therapy for patients with severe aortic stenosis at extreme, high, or intermediate surgical risk. Transfemoral access has been the preferred access route; however, this approach is not suitable for many TAVR candidates. A suprasternal approach may allow for earlier ambulation and shorter hospital stay as compared with other, nontransfemoral approaches. A total of 11 patients with unsuitable transfemoral access underwent suprasternal TAVR. Propensity matching was used to compare suprasternal patients to patients undergoing transaortic, transapical, and trans-subclavian TAVR. Groups were well matched for baseline characteristics. A self-expanding valve device was used in 6 (54.5%) and a balloon-expandable valve in 5 (45.5%) of the 11 patients treated by the suprasternal route. Suprasternal and trans-subclavian patients were able to ambulate earlier than patients treated by the transaortic route, a median 1.6 days (interquartile range [IQR]: 0.9 to 1.8), 1.6 days (IQR: 0.9 to 2.7), and 3.9 days (IQR: 1.9 to 4.5) after the procedure for suprasternal, trans-subclavian, and transaortic patients, respectively (p = 0.001). Length of hospitalization was shorter for patients treated by suprasternal or trans-subclavian access in comparison with patients treated by the transaortic or transapical approach: median 4 days (IQR: 3 to 8) and 4 days (IQR: 4 to 8) versus 8 days (IQR: 6 to 14) and 6 days (IQR: 7 to 11) for suprasternal and trans-subclavian versus transaortic and transapical, respectively (p = 0.01). Suprasternal and trans-subclavian access are associated with earlier ambulation and shorter hospitalization than other nontransfemoral TAVR routes, without an increase in complications. Further study is required to determine if suprasternal is the alternative access of choice for TAVR patients with poor transfemoral vasculature. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights

  2. 4D-Var Developement at GMAO

    NASA Technical Reports Server (NTRS)

    Pelc, Joanna S.; Todling, Ricardo; Akkraoui, Amal El

    2014-01-01

    The Global Modeling and Assimilation Offce (GMAO) is currently using an IAU-based 3D-Var data assimilation system. GMAO has been experimenting with a 3D-Var-hybrid version of its data assimilation system (DAS) for over a year now, which will soon become operational and it will rapidly progress toward a 4D-EnVar. Concurrently, the machinery to exercise traditional 4DVar is in place and it is desirable to have a comparison of the traditional 4D approach with the other available options, and evaluate their performance in the Goddard Earth Observing System (GEOS) DAS. This work will also explore the possibility for constructing a reduced order model (ROM) to make traditional 4D-Var computationally attractive for increasing model resolutions. Part of the research on ROM will be to search for a suitably acceptable space to carry on the corresponding reduction. This poster illustrates how the IAU-based 4D-Var assimilation compares with our currently used IAU-based 3D-Var.

  3. [Cognitive and quality of life trajectory after either surgical or transcatheter aortic valve replacement in high-risk patients].

    PubMed

    Ciuca, Cristina; Fortuna, Daniela; Ferrari, Susy; Salizzoni, Stefano; Grisoglio, Enrica; Punta, Giuseppe; Del Ponte, Stefano; Aranzulla, Tiziana Claudia; Gabbieri, Davide; Gandolfo, Caterina; Dispensa, Flavia; Vecchio Verderame, Lavinia; Tamburino, Corrado; Caruso, Cinzia; Grossi, Claudio; Mikus, Elisa; Guiducci, Vincenzo; Violini, Roberto; Rongoni, Silvia; Pandolfi, Claudia; Moretti, Carolina; De Palma, Rossana; Chattat, Rabih; Savini, Carlo; Marzocchi, Antonio; Saia, Francesco

    2016-12-01

    The impact of transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement (AVR) on cognitive status and quality of life in high-risk patients has been incompletely investigated. We conducted a prospective, multicenter study including all patients treated with TAVI and high-risk patients undergoing AVR (age ≥80 years or logistic EuroSCORE ≥15%) at participating centers. Multidimensional geriatric evaluation including Mini Mental State Examination (MMSE), EuroQol 5D (EQ5D) and Minnesota Living With Heart Failure Questionnaire (MLHFQ) were performed at baseline and at 3- and 12-month follow-up. A total of 518 patients (151 AVR and 367 TAVI) were enrolled in 10 Italian institutions. Patients receiving AVR were older (82.7 ± 2.4 years), with a lower logistic EuroSCORE (12.5 ± 7.1%) as compared with TAVI patients (81.5 ± 6.2 years and 19.6 ± 14.0%, respectively, p=0.001 and p<0.001). Overall, 35.5% of patients showed some degree of cognitive impairment at baseline, with no differences between groups. No significant changes in the cognitive status were observed between baseline and follow-up and between groups at any time point. TAVI patients had a lower quality of life at baseline as compared with AVR patients. Generic and heart failure-related quality of life improved significantly after either procedure. In high-risk patients, both TAVI and AVR are associated with a significant improvement of quality of life up to 1 year without a detrimental effect on cognitive function.

  4. Outcomes of Patients With Severe Chronic Lung Disease Who Are Undergoing Transcatheter Aortic Valve Replacement.

    PubMed

    Suri, Rakesh M; Gulack, Brian C; Brennan, J Matthew; Thourani, Vinod H; Dai, Dadi; Zajarias, Alan; Greason, Kevin L; Vassileva, Christina M; Mathew, Verghese; Nkomo, Vuyisile T; Mack, Michael J; Rihal, Charanjit S; Svensson, Lars G; Nishimura, Rick A; O'Gara, Patrick T; Holmes, David R

    2015-12-01

    In this study, we sought to determine the clinical outcomes after transcatheter aortic valve replacement (TAVR) among patients with chronic lung disease (CLD) and to evaluate the safety of transaortic versus transapical alternate access approaches in patients with varying severities of CLD. Clinical records for patients undergoing TAVR from 2011 to 2014 in The Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry were linked to Medicare hospital claims (n = 11,656). Clinical outcomes were evaluated across strata of CLD severity, and the risk-adjusted association between access route and post-TAVR mortality was determined among patients with severe CLD. In this cohort (median age, 84 years; 51.7% female), moderate to severe CLD was present in 27.7% (14.3%, moderate; 13.4%, severe). Compared with patients with no or mild CLD, patients with severe CLD had a higher rate of post-TAVR mortality to 1-year (32.3% versus 21.0%; adjusted hazard ratio [HR], 1.48; 95% confidence interval [CI], 1.31 to 1.66), as did those with moderate CLD (25.5%; adjusted HR, 1.16; 95% CI, 1.03 to 1.30). The adjusted rate of mortality was similar for transapical versus transaortic approaches to 1 year (adjusted HR, 1.17; 95% CI, 0.83 to 1.65). Moderate or severe CLD is associated with an increased risk of death to 1-year after TAVR, and among patients with severe CLD, the risk of death appears to be similar with either transapical or transaortic alternate-access approaches. Further study is necessary to understand strategies to mitigate risk associated with CLD and the long-term implications of these findings. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Assessment of cardiovascular function following transcatheter aortic valve implantation based on six-minute walk test.

    PubMed

    Chodór, Piotr; Wilczek, Krzysztof; Zielińska, Teresa; Przybylski, Roman; Głowacki, Jan; Włoch, Łukasz; Zembala, Marian; Kalarus, Zbigniew

    2017-01-01

    Transcatheter aortic valve implantation (TAVI) is presently a recognized treatment mo-dality for patients with severe aortic stenosis ineligible for surgery. It reduces mortality as compared to the conservative treatment. It is further expected from this therapy to improve quality of life by improving of the cardiovascular function performance. The aim of this study is to compare patients' cardiovascular system efficiency in the 6-minute walk test (6MWT) made before and after TAVI and at the 6-12-month follow-up. From January 2009 until February 2012, in the Silesian Center for Heart Diseases in Zabrze, TAVI was performed in 104 patients. Eighty-two patients who underwent 6MWT before surgery were qualified for the analysis. The average age of the patients was 76.0 ± 9.17 years, women made 45.1%. The risk of surgical treatment according to the Logistic Euroscore averaged 22.76 ± 12.63%, and by the Society of Thoracic Surgeons - 5.55 ± 3.34%. The 6MWT was performed within 1 month before the TAVI procedure, up to a month after the procedure and during the 6-12-month follow-up. The 6-minute walk test after TAVI was performed by 64 patients, and after 6-12 month follow-up by 46 patients. The average distance in 6MWT increased from 268.4 ± 89.0 m before treat-ment to 290.0 ± 98.2 m after the procedure (p = 0.008) and 276.1 ± 93.5 m to 343.1 ± 96.7 m after 6-12 months (p < 0.0001). Transcatheter aortic valve implantation procedures significantly improve function of the cardiovascular system evaluated by the 6MWT in 1- and 6-12-month observations. (Cardiol J 2017; 24, 2: 167-175).

  6. 4-D spatiotemporal analysis of ultrasound contrast agent dispersion for prostate cancer localization: a feasibility study.

    PubMed

    Schalk, Stefan G; Demi, Libertario; Smeenge, Martijn; Mills, David M; Wallace, Kirk D; de la Rosette, Jean J M C H; Wijkstra, Hessel; Mischi, Massimo

    2015-05-01

    Currently, nonradical treatment for prostate cancer is hampered by the lack of reliable diagnostics. Contrastultrasound dispersion imaging (CUDI) has recently shown great potential as a prostate cancer imaging technique. CUDI estimates the local dispersion of intravenously injected contrast agents, imaged by transrectal dynamic contrast-enhanced ultrasound (DCE-US), to detect angiogenic processes related to tumor growth. The best CUDI results have so far been obtained by similarity analysis of the contrast kinetics in neighboring pixels. To date, CUDI has been investigated in 2-D only. In this paper, an implementation of 3-D CUDI based on spatiotemporal similarity analysis of 4-D DCE-US is described. Different from 2-D methods, 3-D CUDI permits analysis of the entire prostate using a single injection of contrast agent. To perform 3-D CUDI, a new strategy was designed to estimate the similarity in the contrast kinetics at each voxel, and data processing steps were adjusted to the characteristics of 4-D DCE-US images. The technical feasibility of 4-D DCE-US in 3-D CUDI was assessed and confirmed. Additionally, in a preliminary validation in two patients, dispersion maps by 3-D CUDI were quantitatively compared with those by 2-D CUDI and with 12-core systematic biopsies with promising results.

  7. KRN4 Controls Quantitative Variation in Maize Kernel Row Number

    PubMed Central

    Liu, Lei; Du, Yanfang; Shen, Xiaomeng; Li, Manfei; Sun, Wei; Huang, Juan; Liu, Zhijie; Tao, Yongsheng; Zheng, Yonglian; Yan, Jianbing; Zhang, Zuxin

    2015-01-01

    Kernel row number (KRN) is an important component of yield during the domestication and improvement of maize and controlled by quantitative trait loci (QTL). Here, we fine-mapped a major KRN QTL, KRN4, which can enhance grain productivity by increasing KRN per ear. We found that a ~3-Kb intergenic region about 60 Kb downstream from the SBP-box gene Unbranched3 (UB3) was responsible for quantitative variation in KRN by regulating the level of UB3 expression. Within the 3-Kb region, the 1.2-Kb Presence-Absence variant was found to be strongly associated with quantitative variation in KRN in diverse maize inbred lines, and our results suggest that this 1.2-Kb transposon-containing insertion is likely responsible for increased KRN. A previously identified A/G SNP (S35, also known as Ser220Asn) in UB3 was also found to be significantly associated with KRN in our association-mapping panel. Although no visible genetic effect of S35 alone could be detected in our linkage mapping population, it was found to genetically interact with the 1.2-Kb PAV to modulate KRN. The KRN4 was under strong selection during maize domestication and the favorable allele for the 1.2-Kb PAV and S35 has been significantly enriched in modern maize improvement process. The favorable haplotype (Hap1) of 1.2-Kb-PAV-S35 was selected during temperate maize improvement, but is still rare in tropical and subtropical maize germplasm. The dissection of the KRN4 locus improves our understanding of the genetic basis of quantitative variation in complex traits in maize. PMID:26575831

  8. 4D scattering amplitudes and asymptotic symmetries from 2D CFT

    DOE PAGES

    Cheung, Clifford; de la Fuente, Anton; Sundrum, Raman

    2017-01-25

    We reformulate the scattering amplitudes of 4D at space gauge theory and gravity in the language of a 2D CFT on the celestial sphere. The resulting CFT structure exhibits an OPE constructed from 4D collinear singularities, as well as infinite-dimensional Kac-Moody and Virasoro algebras encoding the asymptotic symmetries of 4D at space. We derive these results by recasting 4D dynamics in terms of a convenient foliation of flat space into 3D Euclidean AdS and Lorentzian dS geometries. Tree-level scattering amplitudes take the form of Witten diagrams for a continuum of (A)dS modes, which are in turn equivalent to CFT correlatorsmore » via the (A)dS/CFT dictionary. The Ward identities for the 2D conserved currents are dual to 4D soft theorems, while the bulk-boundary propagators of massless (A)dS modes are superpositions of the leading and subleading Weinberg soft factors of gauge theory and gravity. In general, the massless (A)dS modes are 3D Chern-Simons gauge fields describing the soft, single helicity sectors of 4D gauge theory and gravity. Consistent with the topological nature of Chern-Simons theory, Aharonov-Bohm effects record the \\tracks" of hard particles in the soft radiation, leading to a simple characterization of gauge and gravitational memories. Soft particle exchanges between hard processes define the Kac-Moody level and Virasoro central charge, which are thereby related to the 4D gauge coupling and gravitational strength in units of an infrared cutoff. Lastly, we discuss a toy model for black hole horizons via a restriction to the Rindler region.« less

  9. 4D scattering amplitudes and asymptotic symmetries from 2D CFT

    NASA Astrophysics Data System (ADS)

    Cheung, Clifford; de la Fuente, Anton; Sundrum, Raman

    2017-01-01

    We reformulate the scattering amplitudes of 4D flat space gauge theory and gravity in the language of a 2D CFT on the celestial sphere. The resulting CFT structure exhibits an OPE constructed from 4D collinear singularities, as well as infinite-dimensional Kac-Moody and Virasoro algebras encoding the asymptotic symmetries of 4D flat space. We derive these results by recasting 4D dynamics in terms of a convenient foliation of flat space into 3D Euclidean AdS and Lorentzian dS geometries. Tree-level scattering amplitudes take the form of Witten diagrams for a continuum of (A)dS modes, which are in turn equivalent to CFT correlators via the (A)dS/CFT dictionary. The Ward identities for the 2D conserved currents are dual to 4D soft theorems, while the bulk-boundary propagators of massless (A)dS modes are superpositions of the leading and subleading Weinberg soft factors of gauge theory and gravity. In general, the massless (A)dS modes are 3D Chern-Simons gauge fields describing the soft, single helicity sectors of 4D gauge theory and gravity. Consistent with the topological nature of Chern-Simons theory, Aharonov-Bohm effects record the "tracks" of hard particles in the soft radiation, leading to a simple characterization of gauge and gravitational memories. Soft particle exchanges between hard processes define the Kac-Moody level and Virasoro central charge, which are thereby related to the 4D gauge coupling and gravitational strength in units of an infrared cutoff. Finally, we discuss a toy model for black hole horizons via a restriction to the Rindler region.

  10. Feasibility of 4D flow MR imaging of the brain with either Cartesian y-z radial sampling or k-t SENSE: comparison with 4D Flow MR imaging using SENSE.

    PubMed

    Sekine, Tetsuro; Amano, Yasuo; Takagi, Ryo; Matsumura, Yoshio; Murai, Yasuo; Kumita, Shinichiro

    2014-01-01

    A drawback of time-resolved 3-dimensional phase contrast magnetic resonance (4D Flow MR) imaging is its lengthy scan time for clinical application in the brain. We assessed the feasibility for flow measurement and visualization of 4D Flow MR imaging using Cartesian y-z radial sampling and that using k-t sensitivity encoding (k-t SENSE) by comparison with the standard scan using SENSE. Sixteen volunteers underwent 3 types of 4D Flow MR imaging of the brain using a 3.0-tesla scanner. As the standard scan, 4D Flow MR imaging with SENSE was performed first and then followed by 2 types of acceleration scan-with Cartesian y-z radial sampling and with k-t SENSE. We measured peak systolic velocity (PSV) and blood flow volume (BFV) in 9 arteries, and the percentage of particles arriving from the emitter plane at the target plane in 3 arteries, visually graded image quality in 9 arteries, and compared these quantitative and visual data between the standard scan and each acceleration scan. 4D Flow MR imaging examinations were completed in all but one volunteer, who did not undergo the last examination because of headache. Each acceleration scan reduced scan time by 50% compared with the standard scan. The k-t SENSE imaging underestimated PSV and BFV (P < 0.05). There were significant correlations for PSV and BFV between the standard scan and each acceleration scan (P < 0.01). The percentage of particles reaching the target plane did not differ between the standard scan and each acceleration scan. For visual assessment, y-z radial sampling deteriorated the image quality of the 3 arteries. Cartesian y-z radial sampling is feasible for measuring flow, and k-t SENSE offers sufficient flow visualization; both allow acquisition of 4D Flow MR imaging with shorter scan time.

  11. Molecular determinants of ligand binding modes in the histamine H(4) receptor: linking ligand-based three-dimensional quantitative structure-activity relationship (3D-QSAR) models to in silico guided receptor mutagenesis studies.

    PubMed

    Istyastono, Enade P; Nijmeijer, Saskia; Lim, Herman D; van de Stolpe, Andrea; Roumen, Luc; Kooistra, Albert J; Vischer, Henry F; de Esch, Iwan J P; Leurs, Rob; de Graaf, Chris

    2011-12-08

    The histamine H(4) receptor (H(4)R) is a G protein-coupled receptor (GPCR) that plays an important role in inflammation. Similar to the homologous histamine H(3) receptor (H(3)R), two acidic residues in the H(4)R binding pocket, D(3.32) and E(5.46), act as essential hydrogen bond acceptors of positively ionizable hydrogen bond donors in H(4)R ligands. Given the symmetric distribution of these complementary pharmacophore features in H(4)R and its ligands, different alternative ligand binding mode hypotheses have been proposed. The current study focuses on the elucidation of the molecular determinants of H(4)R-ligand binding modes by combining (3D) quantitative structure-activity relationship (QSAR), protein homology modeling, molecular dynamics simulations, and site-directed mutagenesis studies. We have designed and synthesized a series of clobenpropit (N-(4-chlorobenzyl)-S-[3-(4(5)-imidazolyl)propyl]isothiourea) derivatives to investigate H(4)R-ligand interactions and ligand binding orientations. Interestingly, our studies indicate that clobenpropit (2) itself can bind to H(4)R in two distinct binding modes, while the addition of a cyclohexyl group to the clobenpropit isothiourea moiety allows VUF5228 (5) to adopt only one specific binding mode in the H(4)R binding pocket. Our ligand-steered, experimentally supported protein modeling method gives new insights into ligand recognition by H(4)R and can be used as a general approach to elucidate the structure of protein-ligand complexes.

  12. Vascular complications of transcatheter aortic valve replacement: A concise literature review

    PubMed Central

    Chaudhry, Muhammad Ali; Sardar, Muhammad Rizwan

    2017-01-01

    Transcatheter aortic valve replacement (TAVR) is a relatively newer therapeutic modality which offers a promising alternative to surgical aortic valve replacement for patients with prohibitive, high and intermediate surgical risk. The increasing trend to pursue TAVR in these patients has also led to growing awareness of the associated potential vascular complications. The significant impact of these complications on eventual clinical outcome and mortality makes prompt recognition and timely management a critical factor in TAVR patients. We hereby present a concise review with emphasis on diverse vascular complications associated with TAVR and their effective management to improve overall clinical outcomes. PMID:28824787

  13. Costs of transcatheter versus surgical aortic valve replacement in intermediate-risk patients.

    PubMed

    Osnabrugge, Ruben L J; Head, Stuart J; Genders, Tessa S S; Van Mieghem, Nicolas M; De Jaegere, Peter P T; van der Boon, Robert M A; Kerkvliet, J Marco; Kalesan, Bindu; Bogers, Ad J J C; Kappetein, A Pieter; Hunink, M G Myriam

    2012-12-01

    Transcatheter aortic valve replacement (TAVR) offers a new treatment option for patients with aortic stenosis, but costs may play a decisive role in decision making. Current studies are evaluating TAVR in an intermediate-risk population. We assessed the in-hospital and 1-year follow-up costs of patients undergoing TAVR and surgical aortic valve replacement (SAVR) at intermediate operative risk and identified important cost components. We prospectively collected clinical data on 141 patients undergoing TAVR and 405 undergoing SAVR. Propensity score matching yielded 42 matched pairs at intermediate risk. Costs were assessed using a detailed resource-use approach and compared using bootstrap methods. In-hospital costs were higher in TAVR patients than in SAVR patients (€40802 vs €33354, respectively; p=0.010). The total costs at 1 year were €46217 vs €35511, respectively (p=0.009). The TAVR was less costly with regard to blood products, operating room use, and length-of-stay. For intermediate-risk patients with severe aortic stenosis the costs at 1 year are higher for TAVR than for SAVR. The difference was mainly caused by the higher costs of the transcatheter valve and was not compensated by the lower costs for blood products and hospital stay in TAVR patients. Therefore, SAVR remains a clinically and economically attractive treatment option. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Systematic and quantitative assessment of the effect of chronic kidney disease on CYP2D6 and CYP3A4/5

    PubMed Central

    Yoshida, K; Sun, B; Zhang, L; Zhao, P; Abernethy, DR; Nolin, TD; Rostami‐Hodjegan, A; Zineh, I

    2016-01-01

    Recent reviews suggest that chronic kidney disease (CKD) can affect the pharmacokinetics of nonrenally eliminated drugs, but the impact of CKD on individual elimination pathways has not been systematically evaluated. In this study we developed a comprehensive dataset of the effect of CKD on the pharmacokinetics of CYP2D6‐ and CYP3A4/5‐metabolized drugs. Drugs for evaluation were selected based on clinical drug–drug interaction (CYP3A4/5 and CYP2D6) and pharmacogenetic (CYP2D6) studies. Information from dedicated CKD studies was available for 13 and 18 of the CYP2D6 and CYP3A4/5 model drugs, respectively. Analysis of these data suggested that CYP2D6‐mediated clearance is generally decreased in parallel with the severity of CKD. There was no apparent relationship between the severity of CKD and CYP3A4/5‐mediated clearance. The observed elimination‐route dependency in CKD effects between CYP2D6 and CYP3A4/5 may inform the need to conduct clinical CKD studies with nonrenally eliminated drugs for optimal use of drugs in patients with CKD. PMID:26800425

  15. Comparison of Gavage, Water Bottle, and a High-Moisture Diet Bolus as Dosing Methods for Quantitative D-xylose Administration to B6D2F1 (Mus musculus) Mice

    NASA Technical Reports Server (NTRS)

    Zimmer, J. Paul; Lewis, Sherry M.; Moyer, Jerry L.

    1993-01-01

    Gavage, water bottle, and diet incorporation are 3 dosing methods used orally to administer test compounds to rodents. These 3 methods were compared in mice to determine which represented the most quantitative delivery system. For dietary incorporation, a high-moisture bolus form of NIH-31 rodent meal was developed using hydroxypropyl methylcellulose as an autoclave-stable binding agent. A high-moisture bolus were selected to increase the acceptability of the dosed diet and to promote quantitative consumption through reduced wastage. The test compound used was D-xylose, a pentose sugar that may be quantitatively detected, colorimetrically, in urine following oral dosing. Six male and 6 female B6D2FI mice were placed in metabolism cages and dosed with a known quantity of D-xylose by each of the 3 methods. Urine was collected before and after each method of administration and analysed for total D-xylose; the per cent recovery was based upon the amount of D-xylose consumed. Quantitative consumption was apparently greatest for water bottle dosing with an average recovery of 56.0% of the original D-xylose dose. High-moisture bolus incorporation ranked second with 50.0% D-xylose recovery, and gavage was third with 41.0% D-xylose recovery.

  16. Death and Dialysis After Transcatheter Aortic Valve Replacement: An Analysis of the STS/ACC TVT Registry.

    PubMed

    Hansen, James W; Foy, Andrew; Yadav, Pradeep; Gilchrist, Ian C; Kozak, Mark; Stebbins, Amanda; Matsouaka, Roland; Vemulapalli, Sreekanth; Wang, Alice; Wang, Dee Dee; Eng, Marvin H; Greenbaum, Adam B; O'Neill, William O

    2017-10-23

    The authors sought to elucidate the true incidence of renal replacement therapy (RRT) after transcatheter aortic valve replacement (TAVR). There is a wide discrepancy in the reported rate of RRT after TAVR (1.4% to 40%). The true incidence of RRT after TAVR is unknown. The STS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) registry was linked to the Centers for Medicare & Medicaid database to identify all patients that underwent TAVR from November 2011 through September 2015 and their outcomes. The authors compared rates of death, new RRT, and a composite of both as a function of pre-procedure glomerular filtration rate (GFR), both in stages of chronic kidney disease (CKD), as well as on a continuous scale. Pre-procedure GFR is associated with the risk of death and new RRT after TAVR when GFR is <60 ml/min/m 2 , and increases significantly when GFR falls below 30 ml/min/m 2 . Incremental increases in GFR of 5 ml/min/m 2 were statistically significant (unadjusted hazard ratio: 0.71; p < 0.001) at 30 days, and continued to be significant at 1 year when pre-procedure GFR was <60 ml/min/m 2 . One in 3 CKD stage 4 patients will be dead within 1 year, with 14.6% (roughly 1 in 6) requiring dialysis. In CKD stage 5, more than one-third of patients will require RRT within 30 days; nearly two-thirds will require RRT at 1 year. In both unadjusted and adjusted analysis, pre-procedural GFR was associated with the outcomes of death and new RRT. Increasing CKD stage leads to an increased risk of death and/or RRT. Continuous analysis showed significant differences in outcomes in all levels of CKD when GFR was <60 ml/min/m 2 . Pre-procedure GFR should be considered when selecting CKD patients for TAVR. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  17. A biomechanical modeling guided simultaneous motion estimation and image reconstruction technique (SMEIR-Bio) for 4D-CBCT reconstruction

    NASA Astrophysics Data System (ADS)

    Huang, Xiaokun; Zhang, You; Wang, Jing

    2017-03-01

    Four-dimensional (4D) cone-beam computed tomography (CBCT) enables motion tracking of anatomical structures and removes artifacts introduced by motion. However, the imaging time/dose of 4D-CBCT is substantially longer/higher than traditional 3D-CBCT. We previously developed a simultaneous motion estimation and image reconstruction (SMEIR) algorithm, to reconstruct high-quality 4D-CBCT from limited number of projections to reduce the imaging time/dose. However, the accuracy of SMEIR is limited in reconstructing low-contrast regions with fine structure details. In this study, we incorporate biomechanical modeling into the SMEIR algorithm (SMEIR-Bio), to improve the reconstruction accuracy at low-contrast regions with fine details. The efficacy of SMEIR-Bio is evaluated using 11 lung patient cases and compared to that of the original SMEIR algorithm. Qualitative and quantitative comparisons showed that SMEIR-Bio greatly enhances the accuracy of reconstructed 4D-CBCT volume in low-contrast regions, which can potentially benefit multiple clinical applications including the treatment outcome analysis.

  18. Quantitative 3D analysis of shape dynamics of the left ventricle

    NASA Astrophysics Data System (ADS)

    Scowen, Barry C.; Smith, Stephen L.; Vannan, Mani A.; Arsenault, Marie

    1998-07-01

    There is an established link between Left Ventricular (LV) geometry and its performance. As a consequence of ischemic heart disease and the attempt to relieve myocardial tissue stress, ventricle shape begins to distort from a conical to spherical geometry with a reduction in pumping efficiency of the chamber. If untreated, premature heart failure will result. To increase the changes of successful treatment it is obviously important for the benefit of the patient to detect these abnormalities as soon as possible. It is the development of a technique to characterize and quantify the shape of the left ventricle that is described here. The system described in this paper uses a novel helix model which combines the advantages of current two dimensional (2D) quantitative measures which provide limited information, with 3D qualitative methods which provide accurate reconstructions of the LV using computationally expensive rendering schemes. A phantom object and dog ventricle (normal/abnormal) were imaged and helical models constructed. The result are encouraging with differences between normal and abnormal ventricles in both diastole and systole able to be determined. Further work entails building a library of subjects in order to determine the relationship between ventricle geometry and quantitative measurements.

  19. 32 CFR 1645.4 - Exclusion from Class 4-D.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... MINISTERS OF RELIGION § 1645.4 Exclusion from Class 4-D. A registrant is excluded from Class 4-D when his... duly ordained minister of religion in accordance with the ceremonial rite or discipline of a church... principles of religion and administer the ordinances of public worship, as embodied in the creed or...

  20. 32 CFR 1645.4 - Exclusion from Class 4-D.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... MINISTERS OF RELIGION § 1645.4 Exclusion from Class 4-D. A registrant is excluded from Class 4-D when his... duly ordained minister of religion in accordance with the ceremonial rite or discipline of a church... principles of religion and administer the ordinances of public worship, as embodied in the creed or...

  1. 32 CFR 1645.4 - Exclusion from Class 4-D.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... MINISTERS OF RELIGION § 1645.4 Exclusion from Class 4-D. A registrant is excluded from Class 4-D when his... duly ordained minister of religion in accordance with the ceremonial rite or discipline of a church... principles of religion and administer the ordinances of public worship, as embodied in the creed or...

  2. 32 CFR 1645.4 - Exclusion from Class 4-D.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... MINISTERS OF RELIGION § 1645.4 Exclusion from Class 4-D. A registrant is excluded from Class 4-D when his... duly ordained minister of religion in accordance with the ceremonial rite or discipline of a church... principles of religion and administer the ordinances of public worship, as embodied in the creed or...

  3. 32 CFR 1645.4 - Exclusion from Class 4-D.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... MINISTERS OF RELIGION § 1645.4 Exclusion from Class 4-D. A registrant is excluded from Class 4-D when his... duly ordained minister of religion in accordance with the ceremonial rite or discipline of a church... principles of religion and administer the ordinances of public worship, as embodied in the creed or...

  4. Quantitative 3D high resolution transmission ultrasound tomography: creating clinically relevant images (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Wiskin, James; Klock, John; Iuanow, Elaine; Borup, Dave T.; Terry, Robin; Malik, Bilal H.; Lenox, Mark

    2017-03-01

    There has been a great deal of research into ultrasound tomography for breast imaging over the past 35 years. Few successful attempts have been made to reconstruct high-resolution images using transmission ultrasound. To this end, advances have been made in 2D and 3D algorithms that utilize either time of arrival or full wave data to reconstruct images with high spatial and contrast resolution suitable for clinical interpretation. The highest resolution and quantitative accuracy result from inverse scattering applied to full wave data in 3D. However, this has been prohibitively computationally expensive, meaning that full inverse scattering ultrasound tomography has not been considered clinically viable. Here we show the results of applying a nonlinear inverse scattering algorithm to 3D data in a clinically useful time frame. This method yields Quantitative Transmission (QT) ultrasound images with high spatial and contrast resolution. We reconstruct sound speeds for various 2D and 3D phantoms and verify these values with independent measurements. The data are fully 3D as is the reconstruction algorithm, with no 2D approximations. We show that 2D reconstruction algorithms can introduce artifacts into the QT breast image which are avoided by using a full 3D algorithm and data. We show high resolution gross and microscopic anatomic correlations comparing cadaveric breast QT images with MRI to establish imaging capability and accuracy. Finally, we show reconstructions of data from volunteers, as well as an objective visual grading analysis to confirm clinical imaging capability and accuracy.

  5. Clinical efficacy and safety of transcatheter embolization for vascular complications after percutaneous nephrolithotomy.

    PubMed

    Poyraz, Necdet; Balasar, Mehmet; Gökmen, İbrahim Erdem; Koç, Osman; Sönmez, Mehmet Giray; Aydın, Arif; Göger, Yunus Emre; Öztürk, Ahmet

    2017-12-01

    Percutaneous nephrolithotomy (PNL) is the preferred procedure for safe and effective surgical treatment of kidney stones. Hemorrhage is the most serious complication of PNL, resulting from pseudoaneurysm (PA) or arteriovenous fistula (AVF), and can usually be controlled with conservative treatment. To evaluate endovascular treatments and outcomes of vascular complications observed after PNL. We retrospectively reviewed data on 19 patients who underwent renal embolization due to post-PNL renal artery bleeding between March 2005 and September 2016. Embolization materials included embolization coils and glue. The incidence of post-PNL vascular complications and their endovascular treatments, outcomes, and the follow-up data were analyzed. Nineteen (1.1%) of 1,609 patients (mean age: 44.9 years, range: 19-75 years) underwent angiography and subsequent transcatheter embolization to control bleeding. The mean time to onset of hemorrhage was 7.2 days after PNL (range: 3-18 days). The PNL entry site was the lower calyx in 15 patients, the middle calyx in 3, and the upper calyx in 1. PA, AVF, and PA plus AVF occurred in 14, 5, and 3 of the 19 renal angiography patients, respectively. Embolization of the affected vessels was successful in all 19 patients. The embolization materials of coil, glue, and coil plus glue were used in 16, 3, and 2 patients, respectively. Severe hematuria is a rare complication of PNL and can be successfully treated with transcatheter embolization.

  6. Transcatheter heart valves for the treatment of aortic stenosis: state-of-the-art.

    PubMed

    Del Valle-Fernández, R; Ruiz, C E

    2008-10-01

    Degenerative aortic stenosis is the most frequent heart valve disease. As an alternative to surgical aortic valve replacement, several companies are working on the development of new prosthesis designed to be deployed by transcatheter approaches. Both transfemoral and transapical techniques are feasible, and initial trials in high-risk patients show good procedural outcomes and mid-term (up to 2 years) functionality. Two first-generation prosthesis (Edwards-SAPIEN and CoreValve Revalving System) are commercially available in Europe, and a number of other second-generation valves (with the capabilities of repositioning and retrievability) are under evaluation. Among them, the Sadra-Lotus Valve, The Direct Flow Medical valve and the Paniagua Heart Valve have published first-in-man results; the JenaValve and AorTx devices have also been temporarily implanted in humans. The development of repositionable and retrievable prosthesis with improved profile is mandatory, and it is the main focus of current projects. Not only technical improvements but also operators specialization and an optimal patient selection are essential to improve these initial Some procedural challenges need to be overcome prior to the expansion of these techniques to lower risk groups, and time is needed for detailed long-term outcomes and risk estimations. Only with a close collaboration among different specialists, basic researchers and the industry will the future development of transcatheter aortic implantation techniques be ensured.

  7. Dopamine D4 receptor (D4R) deletion in mice does not affect operant responding for food or cocaine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thanos, P.K.

    In this study we examined the genetic contribution of the D4R in food and cocaine self-administration using D4R mice. Mice were examined for operant responding to food pellets or intravenous cocaine. Compared to wild-type mice (D4R{sup +/+}), both heterozygous (D4R{sup +/-}) and knockout (D4R{sup -/-}) mice showed no difference in responding for food or cocaine. Our findings suggest that the D4R is not directly involved in mediating operant response behaviors for food or cocaine.

  8. SU-E-T-202: Comparison of 4D-Measurement-Guided Dose Reconstructions (MGDR) with COMPASS and OCTAVIUS 4D System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leung, R; Wong, M; Lee, V

    2015-06-15

    Purpose: To cross-validate the MGDR of COMPASS (IBA dosimetry, GmbH, Germany) and OCTAVIUS 4D system (PTW, Freiburg, Germany). Methods: Volumetric-modulated arc plans (5 head-and-neck and 3 prostate) collapsed to 40° gantry on the OCTAVIUS 4D phantom in QA mode on Monaco v5.0 (Elekta, CMS, Maryland Heights, MO) were delivered on a Elekta Agility linac. This study was divided into two parts: (1) error-free measurements by gantry-mounted EvolutionXX 2D array were reconstructed in COMPASS (IBA dosimetry, GmbH, Germany), and by OCTAVIUS 1500 array in Versoft v6.1 (PTW, Freiburg, Germany) to obtain the 3D doses (COM4D and OCTA4D). COM4D and OCTA4D weremore » compared to the raw measurement (OCTA3D) at the same detector plane for which OCTAVIUS 1500 was perpendicular to 0° gantry axis while the plans were delivered at gantry 40°; (2) beam steering errors of energy (Hump=-2%) and symmetry (2T=+2%) were introduced during the delivery of 5 plans to compare the MGDR doses COM4D-Hump (COM4D-2T), OCTA4D-Hump (OCTA4D-2T), with raw doses OCTA3D-Hump (OCTA3D-2T) and with OCTA3D to assess the error reconstruction and detection ability of MGDR tools. All comparisons used Υ-criteria of 2%(local dose)/2mm and 3%/3mm. Results: Averaged Υ passing rates were 85% and 96% for COM4D,and 94% and 99% for OCTA4D at 2%/2mm and 3%/3mm criteria respectively. For error reconstruction, COM4D-Hump (COM4D-2T) showed 81% (93%) at 2%/2mm and 94% (98%) at 3%/3mm, while OCTA4D-Hump (OCTA4D-2T) showed 96% (96%) at 2%/2mm and 99% (99%) at 3%/3mm. For error detection, OCTA3D doses were compared to COM4D-Hump (COM4D-2T) showing Υ passing rates of 93% (93%) at 2%/2mm and 98% (98%), and to OCTA4D-Hump (OCTA4D -2T) showing 94% (99%) at 2%/2mm and 81% (96%) at 3%/3mm, respectively. Conclusion: OCTAVIUS MGDR showed better agreement to raw measurements in both error- and error-free comparisons. COMPASS MGDR deviated from the raw measurements possibly owing to beam modeling uncertainty.« less

  9. Interpreting digit ratio (2D:4D)-behavior correlations: 2D:4D sex difference, stability, and behavioral correlates and their replicability in young children.

    PubMed

    Wong, Wang I; Hines, Melissa

    2016-02-01

    The popularity of using the ratio of the second to the fourth digit (2D:4D) to study influences of early androgen exposure on human behavior relies, in part, on a report that the ratio is sex-dimorphic and stable from age 2 years (Manning etal., 1998). However, subsequent research has rarely replicated this finding. Moreover, although 2D:4D has been correlated with many behaviors, these correlations are often inconsistent. Young children's 2D:4D-behavior correlations may be more consistent than those of older individuals, because young children have experienced fewer postnatal influences. To evaluate the usefulness of 2D:4D as a biomarker of prenatal androgen exposure in studies of 2D:4D-behavior correlations, we assessed its sex difference, temporal stability, and behavioral correlates over a 6- to 8-month period in 126, 2- to 3-year-old children, providing a rare same-sample replicability test. We found a moderate sex difference on both hands and high temporal stability. However, between-sex overlap and within-sex variability were also large. Only 3 of 24 correlations with sex-typed behaviors-scores on the Preschool Activities Inventory (PSAI), preference for a boy-typical toy, preference for a girl-typical toy, were significant and in the predicted direction, all of which involved the PSAI, partially confirming findings from another study. Correlation coefficients were larger for behaviors that showed larger sex differences. But, as in older samples, the overall pattern showed inconsistency across time, sex, and hand. Therefore, although sex-dimorphic and stable, 2D:4D-behavior correlations are no more consistent for young children than for older samples. Theoretical and methodological implications are discussed. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Gravitational wave memory in dS4+2n and 4D cosmology

    NASA Astrophysics Data System (ADS)

    Chu, Y.-Z.

    2017-02-01

    We argue that massless gravitons in all even dimensional de Sitter (dS) spacetimes higher than two admit a linear memory effect arising from their propagation inside the null cone. Assume that gravitational waves (GWs) are being generated by an isolated source, and over only a finite period of time {η\\text{i}}≤slant η ≤slant {η\\text{f}} . Outside of this time interval, suppose the shear-stress of the GW source becomes negligible relative to its energy-momentum and its mass quadrupole moments settle to static values. We then demonstrate, the transverse-traceless (TT) GW contribution to the perturbation of any dS4+2n written in a conformally flat form ({{a}2}{ημ ν}\\text{d}{{x}μ}\\text{d}{{x}ν} )—after the source has ceased and the primary GW train has passed—amounts to a spacetime constant shift in the flat metric proportional to the difference between the TT parts of the source’s final and initial mass quadrupole moments. As a byproduct, we present solutions to Einstein’s equations linearized about de Sitter backgrounds of all dimensions greater than three. We then point out there is a similar but approximate tail induced linear GW memory effect in 4D matter dominated universes. Our work here serves to improve upon and extend the 4D cosmological results of Chu (2015 Phys. Rev. D 92 124038), which in turn preceded complementary work by Bieri et al (2015 arXiv:1509.01296) and by Kehagias and Riotto (2016 arXiv:1602.02653).

  11. Simultaneous motion estimation and image reconstruction (SMEIR) for 4D cone-beam CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Jing; Gu, Xuejun

    2013-10-15

    Purpose: Image reconstruction and motion model estimation in four-dimensional cone-beam CT (4D-CBCT) are conventionally handled as two sequential steps. Due to the limited number of projections at each phase, the image quality of 4D-CBCT is degraded by view aliasing artifacts, and the accuracy of subsequent motion modeling is decreased by the inferior 4D-CBCT. The objective of this work is to enhance both the image quality of 4D-CBCT and the accuracy of motion model estimation with a novel strategy enabling simultaneous motion estimation and image reconstruction (SMEIR).Methods: The proposed SMEIR algorithm consists of two alternating steps: (1) model-based iterative image reconstructionmore » to obtain a motion-compensated primary CBCT (m-pCBCT) and (2) motion model estimation to obtain an optimal set of deformation vector fields (DVFs) between the m-pCBCT and other 4D-CBCT phases. The motion-compensated image reconstruction is based on the simultaneous algebraic reconstruction technique (SART) coupled with total variation minimization. During the forward- and backprojection of SART, measured projections from an entire set of 4D-CBCT are used for reconstruction of the m-pCBCT by utilizing the updated DVF. The DVF is estimated by matching the forward projection of the deformed m-pCBCT and measured projections of other phases of 4D-CBCT. The performance of the SMEIR algorithm is quantitatively evaluated on a 4D NCAT phantom. The quality of reconstructed 4D images and the accuracy of tumor motion trajectory are assessed by comparing with those resulting from conventional sequential 4D-CBCT reconstructions (FDK and total variation minimization) and motion estimation (demons algorithm). The performance of the SMEIR algorithm is further evaluated by reconstructing a lung cancer patient 4D-CBCT.Results: Image quality of 4D-CBCT is greatly improved by the SMEIR algorithm in both phantom and patient studies. When all projections are used to reconstruct a 3D-CBCT by FDK

  12. 2D:4D, Lateralization and Strength in Handball Players

    ERIC Educational Resources Information Center

    Eler, Nebahat; Eler, Serdar

    2018-01-01

    Lateralization, which is also known as hand preference, and 2D:4D finger ratio is a sign of prenatal testosterone and known to be associated with strength. The aim of this study is to investigate the relationship between 2D:4D, lateralization and hand grip strength in relation to hand and forearm that are thought to be effective in handball in…

  13. Management of significant left main coronary disease before and after trans-apical transcatheter aortic valve replacement in a patient with severe and complex arterial disease.

    PubMed

    Paradis, Jean-Michel; George, Isaac; Kodali, Susheel

    2013-09-01

    We report the case of an 81-year-old woman with symptomatic severe aortic stenosis, extremely significant peripheral arterial disease, and obstructive coronary artery disease who underwent percutaneous coronary intervention via a transaxillary conduit immediately before a trans-apical transcatheter aortic valve replacement performed with a transfemoral device. After deployment of the transcatheter heart valve, there was a left main coronary obstruction and the patient required an emergent PCI. This multifaceted case clearly underlines the importance of a well functioning heart team including the interventional cardiologist, the cardiovascular surgeon, and the echocardiographer. Copyright © 2013 Wiley Periodicals, Inc.

  14. 4D flow imaging with MRI

    PubMed Central

    Stankovic, Zoran; Allen, Bradley D.; Garcia, Julio; Jarvis, Kelly B.

    2014-01-01

    Magnetic resonance imaging (MRI) has become an important tool for the clinical evaluation of patients with cardiovascular disease. Since its introduction in the late 1980s, 2-dimensional phase contrast MRI (2D PC-MRI) has become a routine part of standard-of-care cardiac MRI for the assessment of regional blood flow in the heart and great vessels. More recently, time-resolved PC-MRI with velocity encoding along all three flow directions and three-dimensional (3D) anatomic coverage (also termed ‘4D flow MRI’) has been developed and applied for the evaluation of cardiovascular hemodynamics in multiple regions of the human body. 4D flow MRI allows for the comprehensive evaluation of complex blood flow patterns by 3D blood flow visualization and flexible retrospective quantification of flow parameters. Recent technical developments, including the utilization of advanced parallel imaging techniques such as k-t GRAPPA, have resulted in reasonable overall scan times, e.g., 8-12 minutes for 4D flow MRI of the aorta and 10-20 minutes for whole heart coverage. As a result, the application of 4D flow MRI in a clinical setting has become more feasible, as documented by an increased number of recent reports on the utility of the technique for the assessment of cardiac and vascular hemodynamics in patient studies. A number of studies have demonstrated the potential of 4D flow MRI to provide an improved assessment of hemodynamics which might aid in the diagnosis and therapeutic management of cardiovascular diseases. The purpose of this review is to describe the methods used for 4D flow MRI acquisition, post-processing and data analysis. In addition, the article provides an overview of the clinical applications of 4D flow MRI and includes a review of applications in the heart, thoracic aorta and hepatic system. PMID:24834414

  15. Semi Quantitative MALDI TOF for Antimicrobial Susceptibility Testing in Staphylococcus aureus

    DTIC Science & Technology

    2017-08-31

    Semi- quantitative MALDI-TOF for antimicrobial susceptibility testing in Staphylococcus 1 aureus 2 3 4 Tucker Maxson,a Cheryl L. Taylor-Howell,a...Timothy D. Minoguea# 5 6 Diagnostic Systems Division, United States Army Medical Research Institute of Infectious 7 Disease, Fort Detrick, MD...USAa 8 9 Running Title: Quantitative MALDI for AST in S. aureus 10 #Address correspondence to Timothy D. Minogue, timothy.d.minogue.civ@mail.mil

  16. Theoretical level energies and transition data for 4p64d4, 4p64d34f and 4p54d5 configurations of W34+ ion

    NASA Astrophysics Data System (ADS)

    Karpuškienė, R.; Bogdanovich, P.; Kisielius, R.

    2017-05-01

    The ab initio quasirelativistic approach developed specifically for the calculation of spectral parameters of highly charged ions was used to derive transition data for the tungsten ion W34+. The configuration interaction method was applied to include electron correlation effects. The relativistic effects were taken into account in the Breit-Pauli approximation. The level energies, radiative lifetimes τ, Landé g-factors are determined for the ground configuration 4p64d4 and two excited configurations 4p64d34f and 4p54d5. The radiative transition wavelengths λ and emission transition probabilities A for the electric dipole, electric quadrupole, electric octupole, magnetic dipole, and magnetic quadrupole transitions among the levels of these configurations are produced.

  17. Emergency transcatheter arterial embolization for massive gastrointestinal arterial hemorrhage.

    PubMed

    Shi, Zhong Xing; Yang, Jing; Liang, Hong Wei; Cai, Zhen Hua; Bai, Bin

    2017-12-01

    To evaluate the different arteriographic manifestations of acute arterial massive hemorrhage of the gastrointestinal (GI) tract and the efficacy of emergency transcatheter arterial embolization (ETAE).A total of 88 patients with acute massive GI bleeding who experienced failure of initial endoscopy and/or conservative treatment were referred to our interventional department for acute GI arteriography from January 2007 to June 2015. After locating the source of bleeding, appropriate embolic agents, such as spring coil, hydroxyl methyl acrylic acid gelatin microspheres, polyvinyl alcohol (PVA) particles, etc., were used to embolize the targeted vessels. The angiographic manifestations and the effects of embolization of acute arterial massive hemorrhage of the GI tract were retrospectively analyzed.Of the 88 patients, 54 were diagnosed with arterial hemorrhage of the upper GI tract and 34 with arterial hemorrhage of the lower GI tract. Eighty cases were associated with positive angiography, which showed the following: contrast extravasation (only); gastroduodenal artery stenosis; pseudoaneurysm (only); pseudoaneurysm rupture with contrast extravasation; pseudoaneurysms merged with intestinal artery stenosis; GI angiodysplasia; and tumor vascular bleeding. Eight cases were diagnosed with negative angiography. Seven-two patients underwent successful hemostasis, and a total of 81 arteries were embolized. The technical and clinical success rates (no rebleeding within 30 days) in performing transcatheter embolization on patients with active bleeding were 100% and 84.71%, respectively (72 of 85). Within 30 days, the postoperative rebleeding rate was 15.29% (13/85). Of these rebleeding cases, 2 patients were formerly treated with "blind embolization," 7 underwent interventional embolic retreatment, and 3 had surgical operations. All cases were followed-up for 1 month, and 3 patients died from multiple organ failure. No serious complications such as bowel ischemia necrosis

  18. Early Transcatheter Aortic Valve Function With and Without Therapeutic Anticoagulation.

    PubMed

    Hiremath, Pranoti G; Kearney, Kathleen; Smith, Bryn; Don, Creighton; Dvir, Danny; Aldea, Gabriel; Reisman, Mark; McCabe, James M

    2017-11-01

    Prosthetic leaflet thrombosis is a growing concern in transcatheter aortic valve replacement (TAVR). Given the uncertainty of best practices for antiplatelet and anticoagulation therapies in the post-TAVR period, additional evidence regarding the impact of anticoagulation on prosthetic valve function after TAVR is needed. Patients undergoing native-valve TAVR at a single academic institution between 2012 and 2015 were analyzed based on any anticoagulant use at hospital discharge post TAVR. Changes in prosthetic valve peak velocity and mean gradient were assessed based on transthoracic echocardiograms performed immediately following valve implant and at 4-week follow-up. Multivariate regression analyses were performed to explore the impact of anticoagulation status on early TAVR valve performance. For 403 patients, there were no available data to analyze. Of those, 29.6% were discharged on anticoagulation. Following TAVR, the average mean prosthetic valve gradient was 11.8 ± 5.6 mm Hg and peak velocity was 2.33 ± 0.52 m/s. There were no significant differences between anticoagulated and non-anticoagulated groups in the mean or peak gradients or velocity immediately following implant or at 4 weeks, which remained true following multivariate adjustment (P=.80 for delta mean gradient; P=.91 for delta peak velocity). Our data suggest that the absence of anticoagulation is not associated with short-term degradation in TAVR performance and do not support the routine use of anticoagulation following native-valve TAVR.

  19. Geometric validation of self-gating k-space-sorted 4D-MRI vs 4D-CT using a respiratory motion phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yue, Yong, E-mail: yong.yue@cshs.org; Yang, Wensha; McKenzie, Elizabeth

    Purpose: MRI is increasingly being used for radiotherapy planning, simulation, and in-treatment-room motion monitoring. To provide more detailed temporal and spatial MR data for these tasks, we have recently developed a novel self-gated (SG) MRI technique with advantage of k-space phase sorting, high isotropic spatial resolution, and high temporal resolution. The current work describes the validation of this 4D-MRI technique using a MRI- and CT-compatible respiratory motion phantom and comparison to 4D-CT. Methods: The 4D-MRI sequence is based on a spoiled gradient echo-based 3D projection reconstruction sequence with self-gating for 4D-MRI at 3 T. Respiratory phase is resolved by usingmore » SG k-space lines as the motion surrogate. 4D-MRI images are reconstructed into ten temporal bins with spatial resolution 1.56 × 1.56 × 1.56 mm{sup 3}. A MRI-CT compatible phantom was designed to validate the performance of the 4D-MRI sequence and 4D-CT imaging. A spherical target (diameter 23 mm, volume 6.37 ml) filled with high-concentration gadolinium (Gd) gel is embedded into a plastic box (35 × 40 × 63 mm{sup 3}) and stabilized with low-concentration Gd gel. The phantom, driven by an air pump, is able to produce human-type breathing patterns between 4 and 30 respiratory cycles/min. 4D-CT of the phantom has been acquired in cine mode, and reconstructed into ten phases with slice thickness 1.25 mm. The 4D images sets were imported into a treatment planning software for target contouring. The geometrical accuracy of the 4D MRI and CT images has been quantified using target volume, flattening, and eccentricity. The target motion was measured by tracking the centroids of the spheres in each individual phase. Motion ground-truth was obtained from input signals and real-time video recordings. Results: The dynamic phantom has been operated in four respiratory rate (RR) settings, 6, 10, 15, and 20/min, and was scanned with 4D-MRI and 4D-CT. 4D-CT images have target

  20. Evaluation of the safety and efficacy of transcatheter aortic valve implantation in patients with a severe stenotic bicuspid aortic valve in a Chinese population*

    PubMed Central

    Liu, Xian-bao; Jiang, Ju-bo; Zhou, Qi-jing; Pu, Zhao-xia; He, Wei; Dong, Ai-qiang; Feng, Yan; Jiang, Jun; Sun, Yong; Xiang, Mei-xiang; He, Yu-xin; Fan, You-qi; Dong, Liang; Wang, Jian-an

    2015-01-01

    Objective: The purpose of this study is to evaluate the safety and efficacy of transcatheter aortic valve implantation (TAVI) in patients with a severe stenotic bicuspid aortic valve (BAV) in a Chinese population. While several groups have reported the feasibility, efficacy, and safety of TAVI for patients with a BAV, worldwide experience of the technique is still limited, especially in China. Methods: From March 2013 to November 2014, high surgical risk or inoperable patients with symptomatic severe aortic stenosis (AS) who had undergone TAVI at our institution were selected for inclusion in our study. Results were compared between a BAV group and a tricuspid aortic valve (TAV) group. Results: Forty patients were included in this study, 15 (37.5%) of whom were identified as having a BAV. In the BAV group, the aortic valve area was smaller ((0.47±0.13) vs. (0.59±0.14) cm2), the ascending aortic diameter was larger ((40.4±4.4) vs. (36.4±4.3) mm), and the concomitant aortic regurgitation was lower. No significant differences were found between the groups in the other baseline characteristics. No differences were observed either in the choice of access or valve size. The procedural success achieved in this study was 100%. There were no differences between groups in device success (86.7% vs. 88.0%), 30-d mortality (6.7% vs. 8.0%), or 30-d combined end point (13.3% vs. 12.0%). The incidences of new pacemaker implantation, paravalvular regurgitation and other complications, recovery of left ventricle ejection fraction and heart function were similar in both groups. Conclusions: Patients with a severely stenotic BAV can be treated with TAVI, and their condition after treatment should be similar to that of people with a TAV. PMID:25743122

  1. Medicare part D and long-term care: a systematic review of quantitative and qualitative evidence.

    PubMed

    Pimentel, Camilla B; Lapane, Kate L; Briesacher, Becky A

    2013-09-01

    In the largest overhaul to Medicare since its creation in 1965, the Medicare Prescription Drug, Improvement, and Modernization Act of 2003 established Part D in 2006 to improve access to essential medication among disabled and older Americans. Despite previous evidence of a positive impact on the general Medicare population, Part D's overall effects on long-term care (LTC) are unknown. The purpose of this systematic review was to evaluate the literature regarding Part D's impact on the LTC context, specifically costs to LTC residents, providers and payers; prescription drug coverage and utilization; and clinical and administrative outcomes. Four electronic databases [PubMed, Cumulative Index to Nursing and Allied Health Literature (CINAHL), Health Business Fulltext Elite and Science Citation Index Expanded], selected US government and non-profit websites, and bibliographies were searched for quantitative and qualitative studies characterizing Part D in the LTC context. Searches were limited to studies that may have been published between 1 January 2006 (date of Part D implementation) and 8 January 2013. Systematic searches identified 1,624 publications for a three-stage (title, abstract and full-text) review. Included publications were in English language; based in the US; assessed Part D-related outcomes; and included or were directly relevant to LTC residents or settings. News articles, reviews, opinion pieces, letters or commentaries; case reports or case series; simulation or modeling studies; and summaries that did not report original data were excluded. A standardized form was used to abstract study type, study design, LTC setting, sources of data, method of data collection, time periods assessed, unit of observation, outcomes and results. Methodological quality was assessed using modified criteria specific to quantitative and qualitative studies. Eleven quantitative and eight qualitative studies met inclusion criteria. In the seven years since its

  2. Assessment of quality of life in patients after surgical and transcatheter aortic valve replacement.

    PubMed

    Tokarek, Tomasz; Siudak, Zbigniew; Dziewierz, Artur; Sobczyński, Robert; Zasada, Wojciech; Sorysz, Danuta; Olszewska-Wityńska, Katarzyna; Bryniarski, Krzysztof; Krawczyk-Ożóg, Agata; Żabówka, Anna; Sadowski, Jerzy; Dudek, Dariusz

    2016-09-01

    Transcatheter aortic valve implantation (TAVI) and minimally invasive aortic valve replacement (mini-thoracotomy, mini-sternotomy, MIAVR) have become an appealing alternative to conventional surgical (SAVR) treatment of severe aortic stenosis (AS) in high-risk patients. Aim of the study was to evaluate the quality of life (QoL) in patients with AS and treated with transfemoral TAVI, SAVR, mini-thoracotomy and mini-sternotomy. One hundred and seventy-three patients with symptomatic AS were enrolled in 2011-2013. TAVI group consisted of 39 patients (22.5%), mini-sternotomy was performed in 44 patients (25.5%), mini-thoracotomy in 50 (29%), and AVR in 40 patients (23%). QoL was assessed perioperatively, 12 and 24 months after aortic valve replacement (AVR) by Minnesota Living with Heart Failure Questionnaire (MLHFQ) and EQ-5D-3L. Median follow-up was 583.5 (IQR: 298-736) days. Improvement of health status after procedure in comparison with pre-operative period was significantly more often reported after TAVI in perioperative period (90.3%; P = 0.004) and 12 months after procedure (100%, P = 0.02). Global MLHFQ, physical and emotional dimension score at 30-day from AVR presented significant improvement after TAVI in comparison with surgical methods (respectively: 8.3(±8.6), P = 0.003; 4.1(±5.9), P = 0.01; 1.5(±2.6), P = 0.005). Total MLHFQ score was significantly lower (better outcome) in TAVI patients 1 year after procedure (4.8(±6.8), P = 0.004), no differences in somatic and emotional component were found. No differences were found in MLHFQ score 24 months after AVR. Data from EQ-D5-3L questionnaire demonstrated significant improvement of QoL at 30-day follow-up after TAVI in comparison with surgical methods (1.2(±1.7), P = 0.0008). TAVI improves QoL in perioperative and 12 months observation in comparison with mini-thoracotomy, mini-sternotomy and SAVR. Improvement in QoL was obtained in both generic and disease specific

  3. The rationale and design of the Micra Transcatheter Pacing Study: safety and efficacy of a novel miniaturized pacemaker.

    PubMed

    Ritter, Philippe; Duray, Gabor Z; Zhang, Shu; Narasimhan, Calambur; Soejima, Kyoko; Omar, Razali; Laager, Verla; Stromberg, Kurt; Williams, Eric; Reynolds, Dwight

    2015-05-01

    Recent advances in miniaturization technologies and battery chemistries have made it possible to develop a pacemaker small enough to implant within the heart while still aiming to provide similar battery longevity to conventional pacemakers. The Micra Transcatheter Pacing System is a miniaturized single-chamber pacemaker system that is delivered via catheter through the femoral vein. The pacemaker is implanted directly inside the right ventricle of the heart, eliminating the need for a device pocket and insertion of a pacing lead, thereby potentially avoiding some of the complications associated with traditional pacing systems. The Micra Transcatheter Pacing Study is currently undergoing evaluation in a prospective, multi-site, single-arm study. Approximately 720 patients will be implanted at up to 70 centres around the world. The study is designed to have a continuously growing body of evidence and data analyses are planned at various time points. The primary safety and efficacy objectives at 6-month post-implant are to demonstrate that (i) the percentage of Micra patients free from major complications related to the Micra system or implant procedure is significantly higher than 83% and (ii) the percentage of Micra patients with both low and stable thresholds is significantly higher than 80%. The safety performance benchmark is based on a reference dataset of 977 subjects from 6 recent pacemaker studies. The Micra Transcatheter Pacing Study will assess the safety and efficacy of a miniaturized, totally endocardial pacemaker in patients with an indication for implantation of a single-chamber ventricular pacemaker. NCT02004873. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  4. SU-E-J-187: Individually Optimized Contrast-Enhancement 4D-CT for Pancreatic Adenocarcinoma in Radiotherapy Simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xue, M; Patel, K; Regine, W

    2014-06-01

    Purpose: To study the feasibility of individually optimized contrastenhancement (CE) 4D-CT for pancreatic adenocarcinoma (PDA) in radiotherapy simulation. To evaluate the image quality and contrast enhancement of tumor in the CE 4D-CT, compared to the clinical standard of CE 3D-CT and 4D-CT. Methods: In this IRB-approved study, each of the 7 PDA patients enrolled underwent 3 CT scans: a free-breathing 3D-CT with contrast (CE 3D-CT) followed by a 4D-CT without contrast (4D-CT) in the first study session, and a 4D-CT with individually synchronized contrast injection (CE 4D-CT) in the second study session. In CE 4D-CT, the time of full contrastmore » injection was determined based on the time of peak enhancement for the test injection, injection rate, table speed, and longitudinal location and span of the pancreatic region. Physicians contoured both the tumor (T) and the normal pancreatic parenchyma (P) on the three CTs (end-of-exhalation for 4D-CT). The contrast between the tumor and normal pancreatic tissue was computed as the difference of the mean enhancement level of three 1 cm3 regions of interests in T and P, respectively. Wilcoxon rank sum test was used to statistically compare the scores and contrasts. Results: In qualitative evaluations, both CE 3D-CT and CE 4D-CT scored significantly better than 4D-CT (4.0 and 3.6 vs. 2.6). There was no significant difference between CE 3D-CT and CE 4D-CT. In quantitative evaluations, the contrasts between the tumor and the normal pancreatic parenchyma were 0.6±23.4, −2.1±8.0, and −19.6±28.8 HU, in CE 3D-CT, 4D-CT, and CE 4D-CT, respectively. Although not statistically significant, CE 4D-CT achieved better contrast enhancement between the tumor and the normal pancreatic parenchyma than both CE 3D-CT and 4DCT. Conclusion: CE 4D-CT achieved equivalent image quality and better contrast enhancement between tumor and normal pancreatic parenchyma than the clinical standard of CE 3D-CT and 4D-CT. This study was supported

  5. 17 CFR 260.4d-8 - Content.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 17 Commodity and Securities Exchanges 4 2014-04-01 2014-04-01 false Content. 260.4d-8 Section 260.4d-8 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION (CONTINUED) GENERAL RULES AND REGULATIONS, TRUST INDENTURE ACT OF 1939 Rules Under Section 304 § 260.4d-8 Content. (a) Each application for an order under section 304(d) of...

  6. Patent ductus arteriosus with persistent pulmonary artery hypertension after transcatheter closure.

    PubMed

    Feng, Jianqi; Kong, Xiangqing; Sheng, Yanhui; Yang, Rong

    2016-01-01

    To observe the change in pulmonary artery systolic pressure (PASP) of patients with persistent pulmonary arterial hypertension (PAH) after patent ductus arteriosus (PDA) occlusion. After occlusion of PDA in patients with PAH, some patients still tend to suffer from persistent PAH. A chest X-ray, an electrocardiogram, and an echocardiogram were performed on nine patients at 24 hours, 1 and 6 months, and 1 year serially. There was a significant fall ( P <0.05) in mean PASP after occlusion (to 59.3±12.7 mmHg). However, the aortic pressure and systemic arterial oxygen saturation changed slightly ( P >0.05). During the follow up, there was a further fall in the PASP in five patients (No 1, 5, 6, 7, and 8). Four patients (No 2, 3, 4, and 8) showed the evidence of worsening PAH and were treated with sildenafil. Patient 2 died from acute right heart failure after a period of 11 months from the time of transcatheter closure, triggered by pulmonary infection. Some patients with borderline hemodynamic data with PDA and PAH can deteriorate or keep sustained PAH after PDA closure. The treatment of permanent closure to these patients must be cautious.

  7. A multicentre European registry to evaluate the Direct Flow Medical transcatheter aortic valve system for the treatment of patients with severe aortic stenosis.

    PubMed

    Naber, Christoph K; Pyxaras, Stylianos A; Ince, Hüseyin; Frambach, Peter; Colombo, Antonio; Butter, Christian; Gatto, Fernando; Hink, Ulrich; Nickenig, Georg; Bruschi, Giuseppe; Brueren, Guus; Tchétché, Didier; Den Heijer, Peter; Schillinger, Wolfgang; Scholtz, Smita; Van der Heyden, Jan; Lefèvre, Thierry; Gilard, Martine; Kuck, Karl-Heinz; Schofer, Joachim; Divchev, Dimitar; Baumgartner, Helmut; Asch, Federico; Wagner, Daniel; Latib, Azeem; De Marco, Federico; Kische, Stephan

    2016-12-10

    Our aim was to assess the clinical outcomes of the Direct Flow Medical Transcatheter Aortic Valve System (DFM-TAVS), when used in routine clinical practice. This is a prospective, open-label, multicentre, post-market registry of patients treated with DFM-TAVS according to approved commercial indications. Echocardiographic and angiographic data were evaluated by an independent core laboratory and adverse events were adjudicated and classified according to VARC-2 criteria by an independent clinical events committee. The primary endpoint was freedom from all-cause mortality at 30 days post procedure. Secondary endpoints included procedural, early safety and efficacy endpoints at 30 days. Two hundred and fifty patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI) with the DFM-TAVS were enrolled in 21 European centres. The primary endpoint, freedom from all-cause mortality at 30 days, was met in 98% (245/250) of patients. Device success was 83.8%. Moderate or severe aortic regurgitation was reported in 3% of patients, and none/trace regurgitation in 73% of patients. Post-procedural permanent pacemaker implantation was performed in 30 patients (12.0%). The DFM-TAVS was associated with good short-term outcomes in this real-world registry. The low pacemaker and aortic regurgitation rates confirm the advantages of this next-generation transcatheter heart valve (THV).

  8. Short- and long-term results of transcatheter embolization for massive arterial hemorrhage from gastroduodenal ulcers not controlled by endoscopic hemostasis

    PubMed Central

    Loffroy, Romaric; Guiu, Boris; Mezzetta, Lise; Minello, Anne; Michiels, Christophe; Jouve, Jean-Louis; Cheynel, Nicolas; Rat, Patrick; Cercueil, Jean-Pierre; Krausé, Denis

    2009-01-01

    BACKGROUND AND AIM: Severe bleeding from gastrointestinal ulcers is a life-threatening event that is difficult to manage when endoscopic treatment fails. Transcatheter embolization has been suggested as an alternative treatment in this situation. The present study reports on the efficacy and long-term outcomes of transcatheter embolization after failed endoscopic treatments were assessed in high-operative-risk patients. METHODS: A retrospective review of 60 consecutive emergency embolization procedures in hemodynamically unstable patients (41 men, 19 women; mean [±SD] age 69.4±15 years) was conducted. Patients were referred for selective angiography between 1999 and 2008 after failed endoscopic treatment of massive bleeding from gastrointestinal ulcers. Mean follow-up was 22 months. RESULTS: Embolization was feasible and successful in 57 patients. Sandwich coiling of the gastroduodenal artery was used in 34 patients, and superselective occlusion of the terminal feeding artery (with glue, coils or gelatin particles) was used in 23 patients. Early rebleeding occurred in 16 patients and was managed with endoscopy (n=8), reembolization (n=3) or surgery (n=5). No major embolization-related complications occurred. Sixteen patients died within 30 days after embolization (including three who died from rebleeding) and 11 died thereafter. No late bleeding recurrences were reported. CONCLUSIONS: Selective angiographic embolization is safe and effective for controlling life-threatening bleeding from gastroduodenal ulcers. The procedure usually obviates the need for emergency surgery in these high-risk patients. Survival depends chiefly on underlying conditions. PMID:19214287

  9. [Study on the quantitative estimation method for VOCs emission from petrochemical storage tanks based on tanks 4.0.9d model].

    PubMed

    Li, Jing; Wang, Min-Yan; Zhang, Jian; He, Wan-Qing; Nie, Lei; Shao, Xia

    2013-12-01

    VOCs emission from petrochemical storage tanks is one of the important emission sources in the petrochemical industry. In order to find out the VOCs emission amount of petrochemical storage tanks, Tanks 4.0.9d model is utilized to calculate the VOCs emission from different kinds of storage tanks. VOCs emissions from a horizontal tank, a vertical fixed roof tank, an internal floating roof tank and an external floating roof tank were calculated as an example. The consideration of the site meteorological information, the sealing information, the tank content information and unit conversion by using Tanks 4.0.9d model in China was also discussed. Tanks 4.0.9d model can be used to estimate VOCs emissions from petrochemical storage tanks in China as a simple and highly accurate method.

  10. Multi-organ segmentation from multi-phase abdominal CT via 4D graphs using enhancement, shape and location optimization.

    PubMed

    Linguraru, Marius George; Pura, John A; Chowdhury, Ananda S; Summers, Ronald M

    2010-01-01

    The interpretation of medical images benefits from anatomical and physiological priors to optimize computer-aided diagnosis (CAD) applications. Diagnosis also relies on the comprehensive analysis of multiple organs and quantitative measures of soft tissue. An automated method optimized for medical image data is presented for the simultaneous segmentation of four abdominal organs from 4D CT data using graph cuts. Contrast-enhanced CT scans were obtained at two phases: non-contrast and portal venous. Intra-patient data were spatially normalized by non-linear registration. Then 4D erosion using population historic information of contrast-enhanced liver, spleen, and kidneys was applied to multi-phase data to initialize the 4D graph and adapt to patient specific data. CT enhancement information and constraints on shape, from Parzen windows, and location, from a probabilistic atlas, were input into a new formulation of a 4D graph. Comparative results demonstrate the effects of appearance and enhancement, and shape and location on organ segmentation.

  11. Transcatheter Closure of Bilateral Multiple Huge Pulmonary Arteriovenous Malformations with Homemade Double-Umbrella Occluders

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhong Hongshan, E-mail: zhonghongshan@hotmail.com; Xu Ke; Shao Haibo

    2008-07-15

    A 28-year-old man underwent successful transcatheter occlusion of three huge pulmonary arteriovenous malformations (PAVMs) using homemade double-umbrella occluders and stainless steel coils. Thoracic CT with three-dimensional reconstruction and pulmonary angiography were used for treatment planning and follow-up. The diameters of the feeding vessels were 11 mm, 13 mm, and 14 mm, respectively. This report demonstrates the novel design and utility of the double-umbrella occluder, an alternative tool for treatment of large PAVMs.

  12. Outcome after transvascular transcatheter aortic valve implantation in 2016.

    PubMed

    Gaede, Luise; Blumenstein, Johannes; Liebetrau, Christoph; Dörr, Oliver; Kim, Won-Keun; Nef, Holger; Husser, Oliver; Elsässer, Albrecht; Hamm, Christian W; Möllmann, Helge

    2018-02-21

    We analysed the number of procedures, complications, and in-hospital mortality rates of all patients undergoing transvascular transcatheter aortic valve implantation (TV-TAVI) in comparison to isolated surgical aortic valve replacement (iSAVR) from 2014 to 2016 in Germany. All aortic valve procedures performed in Germany are mandatorily registered in a quality control program. More than 15 000 TV-TAVI procedures were performed in 2016 in Germany. Especially the number of post-procedural complications declined within the last few years, including new pacemaker implantations (2015: 12.6% vs. 2016: 11.4%, P = 0.002) and vascular complications (2015: 8.5% vs. 2016: 7.1%; P < 0.001). Thus, in 2016 the overall in-hospital mortality rate after TV-TAVI was 2.6%, which is for the first time numerically below that of iSAVR, which was 2.9% (P = 0.19). A stratified analysis according to the German aortic valve score shows a lower observed than expected in-hospital mortality rate for TV-TAVI (O/E 0.68). Additionally, the in-hospital mortality was significantly lower after TV-TAVI than after iSAVR in the very high- (11.3% vs. 23.6%; P < 0.001), in the high- (4.1% vs. 9.2%; P < 0.001), and in the intermediate-risk group (3.0% vs. 4.6%; P = 0.016) and was similar to that of iSAVR in low-risk patients (1.6% vs. 1.4%; P = 0.4). The overall in-hospital mortality after TV-TAVI was numerically lower than after iSAVR in 2016 for the first time. In the low risk group in-hospital mortality was similar, whereas in all other risk groups in-hospital mortality after TV-TAVI was significantly lower than after SAVR. This is likely to contribute to a redefinition of the standard of care in the future. © The Author 2017. Published by Oxford University Press on behalf of the European Society of Cardiology

  13. Digit ratio (2D:4D) and gender inequalities across nations.

    PubMed

    Manning, John T; Fink, Bernhard; Trivers, Robert

    2014-08-22

    Gender inequality varies across nations, where such inequality is defined as the disproportionate representation of one sex over the other in desirable social, economic, and biological roles (typically male over female). Thus in Norway, 40% of parliamentarians are women, in the USA 17%, and in Saudi Arabia 0%. Some of this variation is associated with economic prosperity but there is evidence that this cause and effect can go in either direction. Here we show that within a population the average ratio of index (2D) to ring (4D) finger lengths (2D:4D)-a proxy measure of the relative degree to which offspring is exposed in utero to testosterone versus estrogen-is correlated with measures of gender inequality between nations. We compared male and female 2D:4D ratios to female parliamentary representation, labor force participation, female education level, maternal mortality rates, and juvenile pregnancy rates per nation in a sample of 29 countries. We found those nations who showed higher than expected female fetal exposure to testosterone (low 2D:4D) and lower than expected male exposure to fetal testosterone (high 2D:4D) had higher rates of female parliamentary representation, and higher female labor force participation. In short, the more similar the two sexes were in 2D:4D, the more equal were the two sexes in parliamentary and labor force participation. The other variables were not as strongly correlated. We suggest that higher than expected fetal testosterone in females and lower fetal testosterone in males may lead to high female representation in the national labor force and in parliament.

  14. 4D MEMRI atlas of neonatal FVB/N mouse brain development.

    PubMed

    Szulc, Kamila U; Lerch, Jason P; Nieman, Brian J; Bartelle, Benjamin B; Friedel, Miriam; Suero-Abreu, Giselle A; Watson, Charles; Joyner, Alexandra L; Turnbull, Daniel H

    2015-09-01

    The widespread use of the mouse as a model system to study brain development has created the need for noninvasive neuroimaging methods that can be applied to early postnatal mice. The goal of this study was to optimize in vivo three- (3D) and four-dimensional (4D) manganese (Mn)-enhanced MRI (MEMRI) approaches for acquiring and analyzing data from the developing mouse brain. The combination of custom, stage-dependent holders and self-gated (motion-correcting) 3D MRI sequences enabled the acquisition of high-resolution (100-μm isotropic), motion artifact-free brain images with a high level of contrast due to Mn-enhancement of numerous brain regions and nuclei. We acquired high-quality longitudinal brain images from two groups of FVB/N strain mice, six mice per group, each mouse imaged on alternate odd or even days (6 3D MEMRI images at each day) covering the developmental stages between postnatal days 1 to 11. The effects of Mn-exposure, anesthesia and MRI were assessed, showing small but significant transient effects on body weight and brain volume, which recovered with time and did not result in significant morphological differences when compared to controls. Metrics derived from deformation-based morphometry (DBM) were used for quantitative analysis of changes in volume and position of a number of brain regions. The cerebellum, a brain region undergoing significant changes in size and patterning at early postnatal stages, was analyzed in detail to demonstrate the spatiotemporal characterization made possible by this new atlas of mouse brain development. These results show that MEMRI is a powerful tool for quantitative analysis of mouse brain development, with great potential for in vivo phenotype analysis in mouse models of neurodevelopmental diseases. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Association Between Transcatheter Aortic Valve Replacement and Subsequent Infective Endocarditis and In-Hospital Death.

    PubMed

    Regueiro, Ander; Linke, Axel; Latib, Azeem; Ihlemann, Nikolaj; Urena, Marina; Walther, Thomas; Husser, Oliver; Herrmann, Howard C; Nombela-Franco, Luis; Cheema, Asim N; Le Breton, Hervé; Stortecky, Stefan; Kapadia, Samir; Bartorelli, Antonio L; Sinning, Jan Malte; Amat-Santos, Ignacio; Munoz-Garcia, Antonio; Lerakis, Stamatios; Gutiérrez-Ibanes, Enrique; Abdel-Wahab, Mohamed; Tchetche, Didier; Testa, Luca; Eltchaninoff, Helene; Livi, Ugolino; Castillo, Juan Carlos; Jilaihawi, Hasan; Webb, John G; Barbanti, Marco; Kodali, Susheel; de Brito, Fabio S; Ribeiro, Henrique B; Miceli, Antonio; Fiorina, Claudia; Dato, Guglielmo Mario Actis; Rosato, Francesco; Serra, Vicenç; Masson, Jean-Bernard; Wijeysundera, Harindra C; Mangione, Jose A; Ferreira, Maria-Cristina; Lima, Valter C; Carvalho, Luiz A; Abizaid, Alexandre; Marino, Marcos A; Esteves, Vinicius; Andrea, Julio C M; Giannini, Francesco; Messika-Zeitoun, David; Himbert, Dominique; Kim, Won-Keun; Pellegrini, Costanza; Auffret, Vincent; Nietlispach, Fabian; Pilgrim, Thomas; Durand, Eric; Lisko, John; Makkar, Raj R; Lemos, Pedro A; Leon, Martin B; Puri, Rishi; San Roman, Alberto; Vahanian, Alec; Søndergaard, Lars; Mangner, Norman; Rodés-Cabau, Josep

    2016-09-13

    Limited data exist on clinical characteristics and outcomes of patients who had infective endocarditis after undergoing transcatheter aortic valve replacement (TAVR). To determine the associated factors, clinical characteristics, and outcomes of patients who had infective endocarditis after TAVR. The Infectious Endocarditis after TAVR International Registry included patients with definite infective endocarditis after TAVR from 47 centers from Europe, North America, and South America between June 2005 and October 2015. Transcatheter aortic valve replacement for incidence of infective endocarditis and infective endocarditis for in-hospital mortality. Infective endocarditis and in-hospital mortality after infective endocarditis. A total of 250 cases of infective endocarditis occurred in 20 006 patients after TAVR (incidence, 1.1% per person-year; 95% CI, 1.1%-1.4%; median age, 80 years; 64% men). Median time from TAVR to infective endocarditis was 5.3 months (interquartile range [IQR], 1.5-13.4 months). The characteristics associated with higher risk of progressing to infective endocarditis after TAVR was younger age (78.9 years vs 81.8 years; hazard ratio [HR], 0.97 per year; 95% CI, 0.94-0.99), male sex (62.0% vs 49.7%; HR, 1.69; 95% CI, 1.13-2.52), diabetes mellitus (41.7% vs 30.0%; HR, 1.52; 95% CI, 1.02-2.29), and moderate to severe aortic regurgitation (22.4% vs 14.7%; HR, 2.05; 95% CI, 1.28-3.28). Health care-associated infective endocarditis was present in 52.8% (95% CI, 46.6%-59.0%) of patients. Enterococci species and Staphylococcus aureus were the most frequently isolated microorganisms (24.6%; 95% CI, 19.1%-30.1% and 23.3%; 95% CI, 17.9%-28.7%, respectively). The in-hospital mortality rate was 36% (95% CI, 30.0%-41.9%; 90 deaths; 160 survivors), and surgery was performed in 14.8% (95% CI, 10.4%-19.2%) of patients during the infective endocarditis episode. In-hospital mortality was associated with a higher logistic EuroSCORE (23.1% vs 18.6%; odds ratio

  16. Evaluation of patients with painful total hip arthroplasty using combined single photon emission tomography and conventional computerized tomography (SPECT/CT) - a comparison of semi-quantitative versus 3D volumetric quantitative measurements.

    PubMed

    Barthassat, Emilienne; Afifi, Faik; Konala, Praveen; Rasch, Helmut; Hirschmann, Michael T

    2017-05-08

    It was the primary purpose of our study to evaluate the inter- and intra-observer reliability of a standardized SPECT/CT algorithm for evaluating patients with painful primary total hip arthroplasty (THA). The secondary purpose was a comparison of semi-quantitative and 3D volumetric quantification method for assessment of bone tracer uptake (BTU) in those patients. A novel SPECT/CT localization scheme consisting of 14 femoral and 4 acetabular regions on standardized axial and coronal slices was introduced and evaluated in terms of inter- and intra-observer reliability in 37 consecutive patients with hip pain after THA. BTU for each anatomical region was assessed semi-quantitatively using a color-coded Likert type scale (0-10) and volumetrically quantified using a validated software. Two observers interpreted the SPECT/CT findings in all patients two times with six weeks interval between interpretations in random order. Semi-quantitative and quantitative measurements were compared in terms of reliability. In addition, the values were correlated using Pearson`s correlation. A factorial cluster analysis of BTU was performed to identify clinically relevant regions, which should be grouped and analysed together. The localization scheme showed high inter- and intra-observer reliabilities for all femoral and acetabular regions independent of the measurement method used (semiquantitative versus 3D volumetric quantitative measurements). A high to moderate correlation between both measurement methods was shown for the distal femur, the proximal femur and the acetabular cup. The factorial cluster analysis showed that the anatomical regions might be summarized into three distinct anatomical regions. These were the proximal femur, the distal femur and the acetabular cup region. The SPECT/CT algorithm for assessment of patients with pain after THA is highly reliable independent from the measurement method used. Three clinically relevant anatomical regions (proximal femoral

  17. New Mononuclear Cu(II) Complexes and 1D Chains with 4-Amino-4H-1,2,4-triazole

    PubMed Central

    Dîrtu, Marinela M.; Boland, Yves; Gillard, Damien; Tinant, Bernard; Robeyns, Koen; Safin, Damir A.; Devlin, Eamonn; Sanakis, Yiannis; Garcia, Yann

    2013-01-01

    The crystal structures of two mononuclear Cu(II) NH2trz complexes [Cu(NH2trz)4(H2O)](AsF6)2 (I) and [Cu(NH2trz)4(H2O)](PF6)2 (II) as well as two coordination polymers [Cu(μ2-NH2trz)2Cl]Cl·H2O (III) and [Cu(μ2-NH2trz)2Cl] (SiF6)0.5·1.5H2O (IV) are presented. Cationic 1D chains with bridging bis-monodentate μ2-coordinated NH2trz and bridging μ2-coordinated chloride ligands are present in III and IV. In these coordination polymers, the Cu(II) ions are strongly antiferromagnetically coupled with J = −128.4 cm−1 for III and J = −143 cm−1 for IV (H = −J∑SiSi+1), due to the nature of the bridges between spin centers. Inter-chain interactions present in the crystal structures were taken into consideration, as well as g factors, which were determined experimentally, for the quantitative modeling of their magnetic properties. PMID:24300095

  18. APA Reporting Standards in Quantitative Research Dissertations from an Online EdD Program

    ERIC Educational Resources Information Center

    Salgado, Griselle

    2013-01-01

    This study was an investigation of the reporting practices in dissertations with quantitative research designs produced by students enrolled in an online Doctor of Education (EdD) program, one that follows the American Psychological Association (APA) standards for reporting research. Limited, empirical information exists about the competencies in…

  19. 2,4-Dichlorophenoxyacetic acid (2,4-D)

    Integrated Risk Information System (IRIS)

    2,4 - Dichlorophenoxyacetic acid ( 2,4 - D ) ; CASRN 94 - 75 - 7 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Asses

  20. Quantitation of valve regurgitation severity by three-dimensional vena contracta area is superior to flow convergence method of quantitation on transesophageal echocardiography.

    PubMed

    Abudiab, Muaz M; Chao, Chieh-Ju; Liu, Shuang; Naqvi, Tasneem Z

    2017-07-01

    Quantitation of regurgitation severity using the proximal isovelocity acceleration (PISA) method to calculate effective regurgitant orifice (ERO) area has limitations. Measurement of three-dimensional (3D) vena contracta area (VCA) accurately grades mitral regurgitation (MR) severity on transthoracic echocardiography (TTE). We evaluated 3D VCA quantitation of regurgitant jet severity using 3D transesophageal echocardiography (TEE) in 110 native mitral, aortic, and tricuspid valves and six prosthetic valves in patients with at least mild valvular regurgitation. The ASE-recommended integrative method comprising semiquantitative and quantitative assessment of valvular regurgitation was used as a reference method, including ERO area by 2D PISA for assigning severity of regurgitation grade. Mean age was 62.2±14.4 years; 3D VCA quantitation was feasible in 91% regurgitant valves compared to 78% by the PISA method. When both methods were feasible and in the presence of a single regurgitant jet, 3D VCA and 2D PISA were similar in differentiating assigned severity (ANOVAP<.001). In valves with multiple jets, however, 3D VCA had a better correlation to assigned severity (ANOVAP<.0001). The agreement of 2D PISA and 3D VCA with the integrative method was 47% and 58% for moderate and 65% and 88% for severe regurgitation, respectively. Measurement of 3D VCA by TEE is superior to the 2D PISA method in determination of regurgitation severity in multiple native and prosthetic valves. © 2017, Wiley Periodicals, Inc.

  1. Clinical efficacy and safety of transcatheter embolization for vascular complications after percutaneous nephrolithotomy

    PubMed Central

    Poyraz, Necdet; Balasar, Mehmet; Gökmen, İbrahim Erdem; Koç, Osman; Aydın, Arif; Göger, Yunus Emre; Öztürk, Ahmet

    2017-01-01

    Introduction Percutaneous nephrolithotomy (PNL) is the preferred procedure for safe and effective surgical treatment of kidney stones. Hemorrhage is the most serious complication of PNL, resulting from pseudoaneurysm (PA) or arteriovenous fistula (AVF), and can usually be controlled with conservative treatment. Aim To evaluate endovascular treatments and outcomes of vascular complications observed after PNL. Material and methods We retrospectively reviewed data on 19 patients who underwent renal embolization due to post-PNL renal artery bleeding between March 2005 and September 2016. Embolization materials included embolization coils and glue. The incidence of post-PNL vascular complications and their endovascular treatments, outcomes, and the follow-up data were analyzed. Results Nineteen (1.1%) of 1,609 patients (mean age: 44.9 years, range: 19–75 years) underwent angiography and subsequent transcatheter embolization to control bleeding. The mean time to onset of hemorrhage was 7.2 days after PNL (range: 3–18 days). The PNL entry site was the lower calyx in 15 patients, the middle calyx in 3, and the upper calyx in 1. PA, AVF, and PA plus AVF occurred in 14, 5, and 3 of the 19 renal angiography patients, respectively. Embolization of the affected vessels was successful in all 19 patients. The embolization materials of coil, glue, and coil plus glue were used in 16, 3, and 2 patients, respectively. Conclusions Severe hematuria is a rare complication of PNL and can be successfully treated with transcatheter embolization. PMID:29362656

  2. Facts and Misconceptions about 2D:4D, Social and Risk Preferences

    PubMed Central

    Alonso, Judit; Di Paolo, Roberto; Ponti, Giovanni; Sartarelli, Marcello

    2018-01-01

    We study how the ratio between the length of the second and fourth digit (2D:4D) correlates with choices in social and risk preferences elicitation tasks by building a large dataset from five experimental projects with more than 800 subjects. Our results confirm the recent literature that downplays the link between 2D:4D and many domains of economic interest, such as social and risk preferences. As for the former, we find that social preferences are significantly lower when 2D:4D is above the median value only for subjects with low cognitive ability. As for the latter, we find that a high 2D:4D is not correlated with the frequency of subjects' risky choices. PMID:29487510

  3. 17 CFR 260.4d-8 - Content.

    Code of Federal Regulations, 2010 CFR

    2000-04-01

    ... 17 Commodity and Securities Exchanges 3 2000-04-01 2000-04-01 false Content. 260.4d-8 Section 260.4d-8 Commodity and Securities Exchanges GENERAL RULES AND REGULATIONS, TRUST INDENTURE ACT OF 1939 Rules Under Section 304 § 260.4d-8 Content. (a) Each application for an order under section 304(d) of...

  4. High-throughput 3D whole-brain quantitative histopathology in rodents

    PubMed Central

    Vandenberghe, Michel E.; Hérard, Anne-Sophie; Souedet, Nicolas; Sadouni, Elmahdi; Santin, Mathieu D.; Briet, Dominique; Carré, Denis; Schulz, Jocelyne; Hantraye, Philippe; Chabrier, Pierre-Etienne; Rooney, Thomas; Debeir, Thomas; Blanchard, Véronique; Pradier, Laurent; Dhenain, Marc; Delzescaux, Thierry

    2016-01-01

    Histology is the gold standard to unveil microscopic brain structures and pathological alterations in humans and animal models of disease. However, due to tedious manual interventions, quantification of histopathological markers is classically performed on a few tissue sections, thus restricting measurements to limited portions of the brain. Recently developed 3D microscopic imaging techniques have allowed in-depth study of neuroanatomy. However, quantitative methods are still lacking for whole-brain analysis of cellular and pathological markers. Here, we propose a ready-to-use, automated, and scalable method to thoroughly quantify histopathological markers in 3D in rodent whole brains. It relies on block-face photography, serial histology and 3D-HAPi (Three Dimensional Histology Analysis Pipeline), an open source image analysis software. We illustrate our method in studies involving mouse models of Alzheimer’s disease and show that it can be broadly applied to characterize animal models of brain diseases, to evaluate therapeutic interventions, to anatomically correlate cellular and pathological markers throughout the entire brain and to validate in vivo imaging techniques. PMID:26876372

  5. Morphologic Characteristics and Relating Factors to the Need of Technical Modification in Transcatheter Closure of Large Atrial Septal Defect (≥25 mm)

    PubMed Central

    Park, Su-Jin; Kim, Nam Kyun; Kim, Jung Ok; Yoo, Byung Won; Sul, Jun Hee

    2010-01-01

    Background and Objectives The rigid coupling between the delivery wire and the right atrial disk has been occasionally encountered during transcatheter closure of atrial septal defect (ASD). Therefore the device frequently makes a perpendicular angle, and the leading edge of left atrial disk slips through the defect and prolapses into right atrium (RA) before it is properly placed in the septum. The purpose of this study is to investigate relating factors to the need of technical modification in transcatheter closure of large ASD and to evaluate relevant morphologic characteristics of atrial septal rim in this situation. Subjects and Methods From July, 2003 to May, 2007, 312 patients underwent transcatheter occlusion of ASD with Amplatzer Septal Occluder® (ASO, AGA medical corporation, Golden Valley, MN, USA) at Yonsei Cardiovascular Center and among them 109 patients had large ASD (≥25 mm) and these patients were enrolled in our study. Patients were divided into two groups according to the deploying methods of the device (Group I: standard method, Group II: modified methods). Assessments of the defects and its surrounding rims were made by echocardiography. Results There were no differences between 2 groups in age, body weight and height except for balloon-stretched diameter (stop-flow technique) and device size. Group II patients with modified methods showed larger balloon-stretched diameter and device size than group I patients with standard method. The mean length of anterosuperior (AS) rim in group II was significantly shorter than group I (p<0.05). As the size of the device used in procedure increased, there was a trend towards increase in the need of modified methods. Conclusion This study shows that AS rim deficiency and the size of ASD may be the relating factors to the need of technical modification in transcatheter closure of ASD. Therefore, when the initial try with standard method is not successful in large ASD with deficient AS rim, we suggest that

  6. Highly accelerated intracranial 4D flow MRI: evaluation of healthy volunteers and patients with intracranial aneurysms.

    PubMed

    Liu, Jing; Koskas, Louise; Faraji, Farshid; Kao, Evan; Wang, Yan; Haraldsson, Henrik; Kefayati, Sarah; Zhu, Chengcheng; Ahn, Sinyeob; Laub, Gerhard; Saloner, David

    2018-04-01

    To evaluate an accelerated 4D flow MRI method that provides high temporal resolution in a clinically feasible acquisition time for intracranial velocity imaging. Accelerated 4D flow MRI was developed by using a pseudo-random variable-density Cartesian undersampling strategy (CIRCUS) with the combination of k-t, parallel imaging and compressed sensing image reconstruction techniques (k-t SPARSE-SENSE). Four-dimensional flow data were acquired on five healthy volunteers and eight patients with intracranial aneurysms using CIRCUS (acceleration factor of R = 4, termed CIRCUS4) and GRAPPA (R = 2, termed GRAPPA2) as the reference method. Images with three times higher temporal resolution (R = 12, CIRCUS12) were also reconstructed from the same acquisition as CIRCUS4. Qualitative and quantitative image assessment was performed on the images acquired with different methods, and complex flow patterns in the aneurysms were identified and compared. Four-dimensional flow MRI with CIRCUS was achieved in 5 min and allowed further improved temporal resolution of <30 ms. Volunteer studies showed similar qualitative and quantitative evaluation obtained with the proposed approach compared to the reference (overall image scores: GRAPPA2 3.2 ± 0.6; CIRCUS4 3.1 ± 0.7; CIRCUS12 3.3 ± 0.4; difference of the peak velocities: -3.83 ± 7.72 cm/s between CIRCUS4 and GRAPPA2, -1.72 ± 8.41 cm/s between CIRCUS12 and GRAPPA2). In patients with intracranial aneurysms, the higher temporal resolution improved capturing of the flow features in intracranial aneurysms (pathline visualization scores: GRAPPA2 2.2 ± 0.2; CIRCUS4 2.5 ± 0.5; CIRCUS12 2.7 ± 0.6). The proposed rapid 4D flow MRI with a high temporal resolution is a promising tool for evaluating intracranial aneurysms in a clinically feasible acquisition time.

  7. Biolabeling with 2,4-dichlorophenoxyacetic acid derivatives: the 2,4-D tag.

    PubMed

    Bade, Steffen; Röckendorf, Niels; Franek, Milan; Gorris, Hans H; Lindner, Buko; Olivier, Verena; Schaper, Klaus-Jürgen; Frey, Andreas

    2009-12-01

    Many bioanalytic and diagnostic procedures rely on labels with which the molecule of interest can be tracked in or discriminated from accompanying like substances. Herein, we describe a new labeling and detection system based on derivatives of 2,4-dichlorophenoxyacetic acid (2,4-D) and anti-2,4-D antibodies. The 2,4-D system is highly sensitive with a K(D) of 7 x 10(-11) M for the hapten-antibody pair, can be used on a large variety of biomolecules such as proteins, peptides, carbohydrates, and nucleic acids, is not hampered by endogenous backgrounds because 2,4-D is a xenobiotic, and is robust because 2,4-D is a very stable compound that withstands the conditions of most reactions usually performed on biomolecules. With this unique blend of properties, the 2,4-D system compares favorably with its rivals digoxigenin (DIG)/anti-DIG and biotin/(strept)avidin and provides an interesting and powerful tool in biomolecular labeling.

  8. 4D spiral imaging of flows in stenotic phantoms and subjects with aortic stenosis.

    PubMed

    Negahdar, M J; Kadbi, Mo; Kendrick, Michael; Stoddard, Marcus F; Amini, Amir A

    2016-03-01

    The utility of four-dimensional (4D) spiral flow in imaging of stenotic flows in both phantoms and human subjects with aortic stenosis is investigated. The method performs 4D flow acquisitions through a stack of interleaved spiral k-space readouts. Relative to conventional 4D flow, which performs Cartesian readout, the method has reduced echo time. Thus, reduced flow artifacts are observed when imaging high-speed stenotic flows. Four-dimensional spiral flow also provides significant savings in scan times relative to conventional 4D flow. In vitro experiments were performed under both steady and pulsatile flows in a phantom model of severe stenosis (one inch diameter at the inlet, with 87% area reduction at the throat of the stenosis) while imaging a 6-cm axial extent of the phantom, which included the Gaussian-shaped stenotic narrowing. In all cases, gradient strength and slew rate for standard clinical acquisitions, and identical field of view and resolution were used. For low steady flow rates, quantitative and qualitative results showed a similar level of accuracy between 4D spiral flow (echo time [TE] = 2 ms, scan time = 40 s) and conventional 4D flow (TE = 3.6 ms, scan time = 1:01 min). However, in the case of high steady flow rates, 4D spiral flow (TE = 1.57 ms, scan time = 38 s) showed better visualization and accuracy as compared to conventional 4D flow (TE = 3.2 ms, scan time = 51 s). At low pulsatile flow rates, a good agreement was observed between 4D spiral flow (TE = 2 ms, scan time = 10:26 min) and conventional 4D flow (TE = 3.6 ms, scan time = 14:20 min). However, in the case of high flow-rate pulsatile flows, 4D spiral flow (TE = 1.57 ms, scan time = 10:26 min) demonstrated better visualization as compared to conventional 4D flow (TE = 3.2 ms, scan time = 14:20 min). The feasibility of 4D spiral flow was also investigated in five normal volunteers and four subjects with mild-to-moderate aortic stenosis. The approach achieved TE = 1.68 ms and scan

  9. A review of state-of-the-art stereology for better quantitative 3D morphology in cardiac research.

    PubMed

    Mühlfeld, Christian; Nyengaard, Jens Randel; Mayhew, Terry M

    2010-01-01

    The aim of stereological methods in biomedical research is to obtain quantitative information about three-dimensional (3D) features of tissues, cells, or organelles from two-dimensional physical or optical sections. With immunogold labeling, stereology can even be used for the quantitative analysis of the distribution of molecules within tissues and cells. Nowadays, a large number of design-based stereological methods offer an efficient quantitative approach to intriguing questions in cardiac research, such as "Is there a significant loss of cardiomyocytes during progression from ventricular hypertrophy to heart failure?" or "Does a specific treatment reduce the degree of fibrosis in the heart?" Nevertheless, the use of stereological methods in cardiac research is rare. The present review article demonstrates how some of the potential pitfalls in quantitative microscopy may be avoided. To this end, we outline the concepts of design-based stereology and illustrate their practical applications to a wide range of biological questions in cardiac research. We hope that the present article will stimulate researchers in cardiac research to incorporate design-based stereology into their study designs, thus promoting an unbiased quantitative 3D microscopy.

  10. Life-threatening hematuria requiring transcatheter embolization following radiofrequency ablation of renal cell carcinoma.

    PubMed

    Roach, H; Whittlestone, T; Callaway, M P

    2006-01-01

    Radiofrequency ablation is increasingly being acknowledged as a valid treatment for renal cell carcinoma in patients in whom definitive curative resection is deemed either undesirable or unsafe. A number of published series have shown the technique to have encouraging results and relatively low complication rates. In this article, we report a case of delayed life-threatening hematuria requiring transcatheter embolization of a bleeding intrarenal artery in a patient who had undergone imaging-guided radiofrequency ablation of a 3 cm renal cell carcinoma. To our knowledge, such a complication has not been reported previously.

  11. 3D quantitative phase imaging of neural networks using WDT

    NASA Astrophysics Data System (ADS)

    Kim, Taewoo; Liu, S. C.; Iyer, Raj; Gillette, Martha U.; Popescu, Gabriel

    2015-03-01

    White-light diffraction tomography (WDT) is a recently developed 3D imaging technique based on a quantitative phase imaging system called spatial light interference microscopy (SLIM). The technique has achieved a sub-micron resolution in all three directions with high sensitivity granted by the low-coherence of a white-light source. Demonstrations of the technique on single cell imaging have been presented previously; however, imaging on any larger sample, including a cluster of cells, has not been demonstrated using the technique. Neurons in an animal body form a highly complex and spatially organized 3D structure, which can be characterized by neuronal networks or circuits. Currently, the most common method of studying the 3D structure of neuron networks is by using a confocal fluorescence microscope, which requires fluorescence tagging with either transient membrane dyes or after fixation of the cells. Therefore, studies on neurons are often limited to samples that are chemically treated and/or dead. WDT presents a solution for imaging live neuron networks with a high spatial and temporal resolution, because it is a 3D imaging method that is label-free and non-invasive. Using this method, a mouse or rat hippocampal neuron culture and a mouse dorsal root ganglion (DRG) neuron culture have been imaged in order to see the extension of processes between the cells in 3D. Furthermore, the tomogram is compared with a confocal fluorescence image in order to investigate the 3D structure at synapses.

  12. 17 CFR 260.4d-8 - Content.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 17 Commodity and Securities Exchanges 3 2013-04-01 2013-04-01 false Content. 260.4d-8 Section 260.4d-8 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION (CONTINUED) GENERAL RULES AND REGULATIONS, TRUST INDENTURE ACT OF 1939 Rules Under Section 304 § 260.4d-8 Content. (a) Each application for an order under section 304(d) of...

  13. 17 CFR 260.4d-8 - Content.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Content. 260.4d-8 Section 260.4d-8 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION (CONTINUED) GENERAL RULES AND REGULATIONS, TRUST INDENTURE ACT OF 1939 Rules Under Section 304 § 260.4d-8 Content. (a) Each application for an order under section 304(d) of...

  14. Fracto-mechanoluminescent light emission of EuD4TEA-PDMS composites subjected to high strain-rate compressive loading

    NASA Astrophysics Data System (ADS)

    Ryu, Donghyeon; Castaño, Nicolas; Bhakta, Raj; Kimberley, Jamie

    2017-08-01

    The objective of this study is to understand light emission characteristics of fracto-mechanoluminescent (FML) europium tetrakis(dibenzoylmethide)-triethylammonium (EuD4TEA) crystals under high strain-rate compressive loading. As a sensing material that can play a pivotal role for the self-powered impact sensor technology, it is important to understand transformative light emission characteristics of the FML EuD4TEA crystals under high strain-rate compressive loading. First, EuD4TEA crystals were synthesized and embedded into polydimethylsiloxane (PDMS) elastomer to fabricate EuD4TEA-PDMS composite test specimens. Second, the prepared EuD4TEA-PDMS composites were tested using the modified Kolsky bar setup equipped with a high-speed camera. Third, FML light emission was captured to yield 12 bit grayscale video footage, which was processed to quantify the FML light emission. Finally, quantitative parameters were generated by taking into account pixel values and population of pixels of the 12 bit grayscale images to represent FML light intensity. The FML light intensity was correlated with high strain-rate compressive strain and strain rate to understand the FML light emission characteristics under high strain-rate compressive loading that can result from impact occurrences.

  15. Effect of transcatheter closure of baffle leaks following senning or mustard atrial redirection surgery on oxygen saturations and polycythaemia.

    PubMed

    Bentham, James; English, Kate; Hares, Dominic; Gibbs, John; Thomson, John

    2012-10-01

    The aim of this study was to describe the clinical importance and methods of transcatheter closure of systemic venous baffle leaks after atrial redirection procedures for transposed great vessels. Until the late 1970s, atrial redirection surgery was the principal surgical palliative approach to manage transposed great vessels. Baffle leaks are among the many long-term complications of this type of surgery, and their prevalence increases over time. The clinical consequences of baffle leaks in this population are poorly understood, and the indications for closure are incompletely defined. During outpatient follow-up of 126 patients after atrial redirection surgery, 15 baffle leaks were detected in 11 patients. All underwent transcatheter closure using either an occluding device or a covered stent if there was concomitant baffle obstruction. The average age at the time of the procedure was 26 years (range 6 to 42). Ten of 11 patients were cyanosed at rest or on a simple walk test (median oxygen saturation level 80%, range 65% to 96%). Six of 11 patients were polycythemic before leak closure (median hemoglobin concentration 19 g/dl, range 13.8 to 23). After closure, there was a significant improvement in saturation (median 97%, p <0.0001) and a significant reduction in hemoglobin concentration at 6 months after the procedure (median 14.8 g/dl, p <0.05). There were no procedural adverse events. One patient experienced late device embolization necessitating surgical removal. In conclusion, transcatheter closure of baffle leaks is a technically feasible although frequently complex and lengthy procedure. Closure is associated with an improvement in oxygen saturations and a reduction in polycythaemia. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. Six-month outcome after transcatheter edge-to-edge repair of severe tricuspid regurgitation in patients with heart failure.

    PubMed

    Orban, Mathias; Besler, Christian; Braun, Daniel; Nabauer, Michael; Zimmer, Marion; Orban, Martin; Noack, Thilo; Mehilli, Julinda; Hagl, Christian; Seeburger, Joerg; Borger, Michael; Linke, Axel; Thiele, Holger; Massberg, Steffen; Ender, Joerg; Lurz, Philipp; Hausleiter, Jörg

    2018-06-01

    Severe tricuspid regurgitation (TR) is common in patients with right-sided heart failure (HF) and causes substantial morbidity and mortality. Treatment options beyond medical therapy are limited for high-risk patients. Transcatheter edge-to-edge tricuspid valve (TV) repair showed procedural safety and short-term efficacy. Impact on mid-term outcome is unclear. This dual-centre observational study evaluates the mid-term safety, efficacy and clinical outcome after edge-to-edge TV repair for severe TR in patients with HF. Overall, 50 patients with right-sided HF and severe TR were treated with the transcatheter edge-to-edge repair technique; 14 patients were treated for isolated TR and 36 patients for combined mitral regurgitation (MR) and TR. At 6-month follow-up (available for 98% of patients), a persistent reduction of at least one echocardiographic TR grade was achieved in 90% of patients and New York Heart Association class improved in 79% of patients. The 6-minute walk distance increased by 44% (+84 m, P < 0.001), the median N-terminal pro-B-type natriuretic peptide decreased by 30% (from 3625 to 2526 pg/mL, P = 0.002), and the quality of life score improved by 16% (decrease of 6 points in the Minnesota Living with Heart Failure Questionnaire score, P = 0.056). The improvements were comparable in patients undergoing isolated TR or combined MR and TR treatment. During follow-up, 8 patients died, 14 were hospitalized for worsening of HF, 2 underwent TV surgery, and 2 received a second TV clip procedure. Transcatheter edge-to-edge TV repair for severe TR is safe and effective in reducing TR. It appears to be associated with improved clinical outcome in the majority of patients. © 2018 The Authors. European Journal of Heart Failure © 2018 European Society of Cardiology.

  17. Transcatheter Aortic Valve Replacement: a Kidney’s Perspective

    PubMed Central

    Cheungpasitporn, Wisit; Thongprayoon, Charat; Kashani, Kianoush

    2016-01-01

    Transcatheter aortic valve replacement (TAVR) has now emerged as a viable treatment option for high-risk patients with severe aortic stenosis (AS) who are not suitable candidates for surgical aortic valve replacement (SAVR). Despite encouraging published outcomes, acute kidney injury (AKI) is common and lowers the survival of patients after TAVR. The pathogenesis of AKI after TAVR is multifactorial including TAVR specific factors such as the use of contrast agents, hypotension during rapid pacing, and embolization; preventive measures may include pre-procedural hydration, limitation of contrast dye exposure, and avoidance of intraprocedural hypotension. In recent years, the number of TAVR performed worldwide has been increasing, as well as published data on renal perspectives of TAVR including AKI, chronic kidney disease, end-stage kidney disease, and kidney transplantation. This review aims to present the current literature on the nephrology aspects of TAVR, ultimately to improve the patients’ quality of care and outcomes. PMID:27069960

  18. Transcatheter aortic valve implantation transapical: step by step.

    PubMed

    Walther, Thomas; Möllmann, Helge; van Linden, Arnaud; Kempfert, Jörg

    2011-01-01

    Transcatheter aortic valve implantation (T-AVI) has been introduced into clinical practice to treat high-risk elderly patients with aortic stenosis. T-AVI can be performed by using a retrograde transfemoral (TF), transsubclavian, transaortic, and/or antegrade transapical (TA) approach. For TA-AVI, CE mark approval was granted in 2008 for the Edwards SAPIEN (Edwards Lifesciences, Irvine, CA) prosthesis with the Ascendra delivery system and in 2010 for the second-generation Edwards SAPIEN XT prosthesis and the Ascendra II delivery system, with 23-mm and 26-mm valves. In 2011, CE mark approval has been granted for TA-AVI by using the SAPIEN XT 29-mm prosthesis. Several other devices from different companies (Jenavalve, Jena Valve Inc, Munich, Germany; Embracer, Medtronic Inc, Guilford, CT; Accurate, Symetis Inc, Geneva, Switzerland) have passed "first in man trials" successfully and are being evaluated within multicenter pivotal studies. In this article we will focus on specific aspects of the TA technique for AVI. Copyright © 2011 Elsevier Inc. All rights reserved.

  19. Pros and cons of transcatheter aortic valve implantation (TAVI).

    PubMed

    Terré, Juan A; George, Isaac; Smith, Craig R

    2017-09-01

    Transcatheter aortic valve implantation (TAVI) or replacement (TAVR) was recently approved by the FDA for intermediate risk patients with severe aortic stenosis (AS). This technique was already worldwide adopted for inoperable and high-risk patients. Improved device technology, imaging analysis and operator expertise has reduced the initial worrisome higher complications rate associated with TAVR, making it comparable to surgical aortic valve replacement (SAVR). However, many answers need to be addressed before adoption in lower risk patients. This paper highlights the pros and cons of TAVI based mostly on randomized clinical trials involving the two device platforms approved in the United States. We focused our analysis on metrics that will play a key role in expanding TAVR indication in healthier individuals. We review the significance and gave a perspective on paravalvular leak (PVL), valve performance, valve durability, leaflet thrombosis, stroke and pacemaker requirement.

  20. Development of an immunoassay for determination of 2,4-dichlorophenoxyacetic acid (2,4-D) based upon the recombinant Fab fragment of 2,4-D specific antibody

    NASA Astrophysics Data System (ADS)

    Nguyen, Van C.; Nguyen, Thi D. T.; Dau, Hung A.; Tham, Thu N.; Quyen, Dinh T.; Bachmman, Till; Schmid, Rolf D.

    2001-09-01

    To develop an immunoassay and further an immunosensor for 2,4-D based upon recombinant antibody, the Fab fragments of 2,4-D specific antibody were expressed in E. coli. Western blotting analysis of the periplasmic cell fractions shown that under the non-reducing condition only a single protein band at a molecular mass of 45-kDa, corresponding to the whole Fab fragment was detected. Antigen binding activity for 2,4-D was found only in the extract of cells bearing the 2,4-D plasmid. An immunoassay based on the competitive reaction of 2,4-D and enzyme tracer with 2,4-D Fab fragments immobilized on micro titer plates via rabbit anti-mouse IgC was developed. Using this assay, 2,4-D could be detected at concentration range of 0.5 (mu) g/1 to 10(mu) g/1. The center point of the 2,4-D test was found at a concentration of 5 (mu) g/l. The assay was applied for detection of 2,4-D in spiked orange samples, resulting in recovery rate of 90 percent. The immunoassay could be applied to monitor human exposure to 2,4-D from contamination in fruit samples.

  1. Transcatheter closure, mini-invasive closure and open-heart surgical repair for treatment of perimembranous ventricular septal defects in children: a protocol for a network meta-analysis.

    PubMed

    You, Tao; Yi, Kang; Ding, Zhao-Hong; Hou, Xiao-Dong; Liu, Xing-Guang; Wang, Xin-Kuan; Ge, Long; Tian, Jin-Hui

    2017-06-21

    Both transcatheter device closure and surgical repair are effective treatments with excellent midterm outcomes for perimembranous ventricular septal defects (pmVSDs) in children. The mini-invasive periventricular device occlusion technique has become prevalent in research and application, but evidence is limited for the assessment of transcatheter closure, mini-invasive closure and open-heart surgical repair. This study comprehensively compares the efficacy, safety and costs of transcatheter closure, mini-invasive closure and open-heart surgical repair for treatment of pmVSDs in children using Bayesian network meta-analysis. A systematic search will be performed using Chinese Biomedical Literature Database, China National Knowledge Infrastructure, PubMed, EMBASE.com and the Cochrane Central Register of Controlled Trials to include random controlled trials, prospective or retrospective cohort studies comparing the efficacy, safety and costs of transcatheter closure, mini-invasive closure and open-heart surgical repair. The risk of bias for the included prospective or retrospective cohort studies will be evaluated according to the risk of bias in non-randomised studies of interventions (ROBINS-I). For random controlled trials, we will use risk of bias tool from Cochrane Handbook version 5.1.0. A Bayesian network meta-analysis will be conducted using R-3.3.2 software. Ethical approval and patient consent are not required since this study is a network meta-analysis based on published trials. The results of this network meta-analysis will be submitted to a peer-reviewed journal for publication. CRD42016053352. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. Transcatheter Closure of Patent Ductus Arteriosus in Children with the Occlutech Duct Occluder.

    PubMed

    Bilici, Meki; Demir, Fikri; Akın, Alper; Türe, Mehmet; Balık, Hasan; Kuyumcu, Mahir

    2017-12-01

    The aim of this study was to evaluate the feasibility, efficacy and safety of transcatheter closure of patent ductus arteriosus (PDA) with the Occlutech duct occluder (ODO) in children. We reviewed the clinical records of 71 patients who underwent percutaneous closure of PDA with an ODO between September 2014 and August 2016. The Occlutech duct occluder was applied to 71 patients during the study period (September 2014-August 2016), and the results were analyzed in this study. Forty-two of the patients were female and 29 male. The median age was 20.5 months (range, 6-194 months) and median weight was 16 kg (range, 6-68 kg). The PDA was classified as type A in 54 patients (76.1%), type E in 14 (19.7%), type C in 2 (2.8%) and type B in 1 (1.4%) based on the Krichenko classification. A standard ODO device was used for the transcatheter closure procedure in 66 patients and the long-shank ODO device in 5. In the echocardiographic measurement of PDA, the median smallest diameter was 2.7 mm (range, 1.5-7.0 mm), and in the angiographic measurement, the median smallest diameter was 2.5 mm (range, 1.5-6.5 mm). All 71 patients underwent successful PDA closure with the ODO. Angiography following the procedure showed complete closure in 47 patients (66.2%), mild residual shunt in 13 patients (18.3%) and a trivial shunt in 11 patients (15.5%). Color flow Doppler echocardiogpaphy at 24 h post-implantation showed that complete closure was achieved in 65 patients (91.5%), and 6 patients (8.5%) had mild residual shunt. All patients (100%) had complete closure at 30 days of follow-up. The results of this study showed that the Occlutech PDA occluder device is safe and effective in the closure of PDA. As the pulmonary artery side of the device is wider than the aortic side, protrusion toward the aortic side and embolization are prevented, but there is residual shunt in the early period, although this residual shunt disappeared after a few months.

  3. Cerebrovascular accidents complicating transcatheter aortic valve implantation: frequency, timing and impact on outcomes.

    PubMed

    Stortecky, Stefan; Windecker, Stephan; Pilgrim, Thomas; Heg, Dik; Buellesfeld, Lutz; Khattab, Ahmed A; Huber, Christoph; Gloekler, Steffen; Nietlispach, Fabian; Mattle, Heinrich; Jüni, Peter; Wenaweser, Peter

    2012-05-15

    Cerebrovascular accidents (CVA) are considered among the most serious adverse events after transcatheter aortic valve implantation (TAVI). The objective of the present study was to evaluate the frequency and timing of CVA after TAVI and to investigate the impact on clinical outcomes within 30 days of the procedure. Between August 2007 and October 2011, 389 high-risk elderly patients with symptomatic severe aortic stenosis underwent TAVI via transfemoral, transapical or subclavian access. A total of 14 patients (3.6%) experienced at least one CVA within 30 days of follow-up and most events (74%) occurred within the first day of the procedure. Patients with CVA had an increased risk of all-cause (42.3% vs. 5.1%, ORadjusted 11.7, 95% CI 3.4-40.3, p<0.001) and cardiovascular mortality (38.4% vs. 4.6%, ORadjusted 10.5, 95% CI 2.9-37.8, p<0.001) compared to patients without CVA at 30 days of follow-up. Repeated device implantation attempts (ORadjusted 8.3, CI 2.1-33.3, p<0.003), chronic pulmonary disease (ORadjusted 4.7, CI 1.3-16.8, p=0.02) and body mass index <25 kg/m2 (ORadjusted 0.8, CI 0.7-0.9, p<0.01) emerged as independent predictors of periprocedural CVA. Cerebrovascular accidents among patients undergoing TAVI occur predominantly during the periprocedural period, are associated with multiple implantation attempts of the bioprosthesis and significantly impair prognosis.

  4. Quantitative evaluation of 3D dosimetry for stereotactic volumetric‐modulated arc delivery using COMPASS

    PubMed Central

    Manigandan, Durai; Karrthick, Karukkupalayam Palaniappan; Sambasivaselli, Raju; Senniandavar, Vellaingiri; Ramu, Mahendran; Rajesh, Thiyagarajan; Lutz, Muller; Muthukumaran, Manavalan; Karthikeyan, Nithyanantham; Tejinder, Kataria

    2014-01-01

    The purpose of this study was to evaluate quantitatively the patient‐specific 3D dosimetry tool COMPASS with 2D array MatriXX detector for stereotactic volumetric‐modulated arc delivery. Twenty‐five patients CT images and RT structures from different sites (brain, head & neck, thorax, abdomen, and spine) were taken from CyberKnife Multiplan planning system for this study. All these patients underwent radical stereotactic treatment in CyberKnife. For each patient, linac based volumetric‐modulated arc therapy (VMAT) stereotactic plans were generated in Monaco TPS v3.1 using Elekta Beam Modulator MLC. Dose prescription was in the range of 5–20 Gy per fraction. Target prescription and critical organ constraints were tried to match the delivered treatment plans. Each plan quality was analyzed using conformity index (CI), conformity number (CN), gradient Index (GI), target coverage (TC), and dose to 95% of volume (D95). Monaco Monte Carlo (MC)‐calculated treatment plan delivery accuracy was quantitatively evaluated with COMPASS‐calculated (CCA) dose and COMPASS indirectly measured (CME) dose based on dose‐volume histogram metrics. In order to ascertain the potential of COMPASS 3D dosimetry for stereotactic plan delivery, 2D fluence verification was performed with MatriXX using MultiCube phantom. Routine quality assurance of absolute point dose verification was performed to check the overall delivery accuracy. Quantitative analyses of dose delivery verification were compared with pass and fail criteria of 3 mm and 3% distance to agreement and dose differences. Gamma passing rate was compared with 2D fluence verification from MatriXX with MultiCube. Comparison of COMPASS reconstructed dose from measured fluence and COMPASS computed dose has shown a very good agreement with TPS calculated dose. Each plan was evaluated based on dose volume parameters for target volumes such as dose at 95% of volume (D95) and average dose. For critical organs dose at 20% of

  5. Transcatheter aortic valve replacement using a self-expanding bioprosthesis in patients with severe aortic stenosis at extreme risk for surgery.

    PubMed

    Popma, Jeffrey J; Adams, David H; Reardon, Michael J; Yakubov, Steven J; Kleiman, Neal S; Heimansohn, David; Hermiller, James; Hughes, G Chad; Harrison, J Kevin; Coselli, Joseph; Diez, Jose; Kafi, Ali; Schreiber, Theodore; Gleason, Thomas G; Conte, John; Buchbinder, Maurice; Deeb, G Michael; Carabello, Blasé; Serruys, Patrick W; Chenoweth, Sharla; Oh, Jae K

    2014-05-20

    This study sought to evaluate the safety and efficacy of the CoreValve transcatheter heart valve (THV) for the treatment of severe aortic stenosis in patients at extreme risk for surgery. Untreated severe aortic stenosis is a progressive disease with a poor prognosis. Transcatheter aortic valve replacement (TAVR) with a self-expanding bioprosthesis is a potentially effective therapy. We performed a prospective, multicenter, nonrandomized investigation evaluating the safety and efficacy of self-expanding TAVR in patients with symptomatic severe aortic stenosis with prohibitive risks for surgery. The primary endpoint was a composite of all-cause mortality or major stroke at 12 months, which was compared with a pre-specified objective performance goal (OPG). A total of 41 sites in the United States recruited 506 patients, of whom 489 underwent attempted treatment with the CoreValve THV. The rate of all-cause mortality or major stroke at 12 months was 26.0% (upper 2-sided 95% confidence bound: 29.9%) versus 43.0% with the OPG (p < 0.0001). Individual 30-day and 12-month events included all-cause mortality (8.4% and 24.3%, respectively) and major stroke (2.3% and 4.3%, respectively). Procedural events at 30 days included life-threatening/disabling bleeding (12.7%), major vascular complications (8.2%), and need for permanent pacemaker placement (21.6%). The frequency of moderate or severe paravalvular aortic regurgitation was lower 12 months after self-expanding TAVR (4.2%) than at discharge (10.7%; p = 0.004 for paired analysis). TAVR with a self-expanding bioprosthesis was safe and effective in patients with symptomatic severe aortic stenosis at prohibitive risk for surgical valve replacement. (Safety and Efficacy Study of the Medtronic CoreValve System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement; NCT01240902). Copyright © 2014 American College of Cardiology Foundation. Published by

  6. Effect of Serum C-Reactive Protein Level on Admission to Predict Mortality After Transcatheter Aortic Valve Implantation.

    PubMed

    Hioki, Hirofumi; Watanabe, Yusuke; Kozuma, Ken; Yamamoto, Masanori; Naganuma, Toru; Araki, Motoharu; Tada, Norio; Shirai, Shinichi; Yamanaka, Futoshi; Higashimori, Akihiro; Mizutani, Kazuki; Tabata, Minoru; Takagi, Kensuke; Ueno, Hiroshi; Hayashida, Kentaro

    2018-04-12

    The relation between C-reactive protein (CRP) level on admission and mortality after transcatheter aortic valve implantation (TAVI) remains unclear. To evaluate the impact of serum CRP level on mortality after TAVI, we assessed 1,016 patients with CRP who underwent TAVI and 538 patients with high-sensitive CRP (hs-CRP) level who underwent TAVI on admission in the OCEAN (Optimized Transcatheter Valvular Intervention)-TAVI registry. Study population was stratified into 2 groups (high/low), according to the median of CRP and hs-CRP on admission. We assessed the impact of high CRP and hs-CRP level on all-cause death after TAVI. During 2-year follow-up, all-cause death after TAVI was 9.4% in patients with CRP and 11.9% in patients with hs-CRP. Median value of serum CRP was 0.10 mg/dl in both CRP and hs-CRP. Patients with high CRP (>0.10 mg/dl) had significantly higher incidence of all-cause death compared with those with low CRP (11.5% vs 7.6%, log-rank p = 0.015). Multivariate Cox regression analysis with a time-varying covariate demonstrated that high CRP was an independent predictor of all-cause death within the first 3 months (hazard ratio 2.78, 95% CI 1.30 to 5.95) compared with from 3 months to 2 years (hazard ratio 0.80, 95% CI 0.47 to 1.36) (P for interaction = 0.008). Inversely, these results were not observed in the stratification using hs-CRP on admission. In conclusion, high CRP on admission was significantly associated with an increased risk of all-cause death after TAVI, particularly within the first 3 months after TAVI. Risk stratification using CRP may be a simple and useful strategy to identify high-risk patients who undergo TAVI. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Supplement to CCM.D-K4 'Hydrometer' report: linkage of EURAMET.M.D-K4 comparison, SIM.M.D-K4 comparison and the supplementary SIM.M.D-S2 to CCM.D-K4 'Hydrometer'

    NASA Astrophysics Data System (ADS)

    Lorefice, S.; Becerra, L. O.

    2017-01-01

    Evaluation of different types of comparisons to a common set of reference values of a CIPM key comparison is essential to satisfy the concept of the CIPM Mutual Recognition Arrangement (CIPM MRA), where the DoEs of any participant who took part in comparisons should be within the Calibration and Measurement Capability (CMC) section of the CIPM MRA Key Comparison Data Base. The subject of this supplementary report is therefore to present the equivalence of each National Metrological Institute (NMI) participant in the CCM.D-K4 'Hydrometer' key comparison, which was performed in the density range 600 kg/m3 to 2000 kg/m3 at the temperature of 20 °C, and the linkage of the European and Inter-American NMI results performed in the RMO.M.D-K4 comparisons as well as those of the supplementary SIM.M.D-S2 to the common set of KCRVs of the CCM.D-K4 'Hydrometer'. The linking procedure has been obtained by numerical simulation, based on the Monte Carlo method, in which the differences in the results of the different comparison between the intended laboratory and one or more linking laboratory/ies, which took part in both comparisons, are correlated with a continuous function describing the DoEs of the linking laboratory/ies with respect to the common set of KCRVs of the CCM.D-K4. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. Percutaneous management of vascular access in transfemoral transcatheter aortic valve implantation

    PubMed Central

    Dato, Ilaria; Burzotta, Francesco; Trani, Carlo; Crea, Filippo; Ussia, Gian Paolo

    2014-01-01

    Transcatheter aortic valve implantation (TAVI) using stent-based bioprostheses has recently emerged as a promising alternative to surgical valve replacement in selected patients. The main route for TAVI is retrograde access from the femoral artery using large sheaths (16-24 F). Vascular access complications are a clinically relevant issue in TAVI procedures since they are reported to occur in up to one fourth of patients and are strongly associated with adverse outcomes. In the present paper, we review the different types of vascular access site complications associated with transfemoral TAVI. Moreover, we discuss the possible optimal management strategies with particular attention to the relevance of early diagnosis and prompt treatment using endovascular techniques. PMID:25228962

  9. 3D and 4D echo--applications in EP laboratory procedures.

    PubMed

    Kautzner, Josef; Peichl, Petr

    2008-08-01

    3D echocardiography allows imaging and analysis of cardiovascular structures as they move in time and space, thus creating possibility for creation of 4D datasets (3D + time). Intracardiac echocardiography (ICE) further broadens the spectrum of echocardiographic techniques by allowing detailed imaging of intracardiac anatomy with 3D reconstructions. The paper reviews the current status of development of 3D and 4D echocardiography in electrophysiology. In ablation area, 3D echocardiography can enhance the performance of catheter ablation for complex arrhythmias such as atrial fibrillation. Currently, several strategies to obtain 3D reconstructions from ICE are available. One involves combination with electroanatomical mapping system; others create reconstruction from standard phased-array or single-element ICE catheter using special rotational or pull-back devices. Secondly, 3D echocardiography may be used for precise assessment of cardiac dyssynchrony before cardiac resynchronization therapy. Its reliable detection is expected to minimize number of non-responders to this treatment and optimize left ventricular lead positioning to get maximum hemodynamic benefit. The main potential benefit of 3D and 4D echocardiography in electrophysiology lie in real-time guidance of complex ablation procedures and precise assessment of cardiac dyssynchrony.

  10. Low 2D:4D values are associated with video game addiction.

    PubMed

    Kornhuber, Johannes; Zenses, Eva-Maria; Lenz, Bernd; Stoessel, Christina; Bouna-Pyrrou, Polyxeni; Rehbein, Florian; Kliem, Sören; Mößle, Thomas

    2013-01-01

    Androgen-dependent signaling regulates the growth of the fingers on the human hand during embryogenesis. A higher androgen load results in lower 2D:4D (second digit to fourth digit) ratio values. Prenatal androgen exposure also impacts brain development. 2D:4D values are usually lower in males and are viewed as a proxy of male brain organization. Here, we quantified video gaming behavior in young males. We found lower mean 2D:4D values in subjects who were classified according to the CSAS-II as having at-risk/addicted behavior (n = 27) compared with individuals with unproblematic video gaming behavior (n = 27). Thus, prenatal androgen exposure and a hyper-male brain organization, as represented by low 2D:4D values, are associated with problematic video gaming behavior. These results may be used to improve the diagnosis, prediction, and prevention of video game addiction.

  11. 4D Bioprinting for Biomedical Applications.

    PubMed

    Gao, Bin; Yang, Qingzhen; Zhao, Xin; Jin, Guorui; Ma, Yufei; Xu, Feng

    2016-09-01

    3D bioprinting has been developed to effectively and rapidly pattern living cells and biomaterials, aiming to create complex bioconstructs. However, placing biocompatible materials or cells into direct contact via bioprinting is necessary but insufficient for creating these constructs. Therefore, '4D bioprinting' has emerged recently, where 'time' is integrated with 3D bioprinting as the fourth dimension, and the printed objects can change their shapes or functionalities when an external stimulus is imposed or when cell fusion or postprinting self-assembly occurs. In this review, we highlight recent developments in 4D bioprinting technology. Additionally, we review the uses of 4D bioprinting in tissue engineering and drug delivery. Finally, we discuss the major roadblocks to this approach, together with possible solutions, to provide future perspectives on this technology. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Respiratory motion correction in 4D-PET by simultaneous motion estimation and image reconstruction (SMEIR)

    PubMed Central

    Kalantari, Faraz; Li, Tianfang; Jin, Mingwu; Wang, Jing

    2016-01-01

    In conventional 4D positron emission tomography (4D-PET), images from different frames are reconstructed individually and aligned by registration methods. Two issues that arise with this approach are as follows: 1) the reconstruction algorithms do not make full use of projection statistics; and 2) the registration between noisy images can result in poor alignment. In this study, we investigated the use of simultaneous motion estimation and image reconstruction (SMEIR) methods for motion estimation/correction in 4D-PET. A modified ordered-subset expectation maximization algorithm coupled with total variation minimization (OSEM-TV) was used to obtain a primary motion-compensated PET (pmc-PET) from all projection data, using Demons derived deformation vector fields (DVFs) as initial motion vectors. A motion model update was performed to obtain an optimal set of DVFs in the pmc-PET and other phases, by matching the forward projection of the deformed pmc-PET with measured projections from other phases. The OSEM-TV image reconstruction was repeated using updated DVFs, and new DVFs were estimated based on updated images. A 4D-XCAT phantom with typical FDG biodistribution was generated to evaluate the performance of the SMEIR algorithm in lung and liver tumors with different contrasts and different diameters (10 to 40 mm). The image quality of the 4D-PET was greatly improved by the SMEIR algorithm. When all projections were used to reconstruct 3D-PET without motion compensation, motion blurring artifacts were present, leading up to 150% tumor size overestimation and significant quantitative errors, including 50% underestimation of tumor contrast and 59% underestimation of tumor uptake. Errors were reduced to less than 10% in most images by using the SMEIR algorithm, showing its potential in motion estimation/correction in 4D-PET. PMID:27385378

  13. Respiratory motion correction in 4D-PET by simultaneous motion estimation and image reconstruction (SMEIR)

    NASA Astrophysics Data System (ADS)

    Kalantari, Faraz; Li, Tianfang; Jin, Mingwu; Wang, Jing

    2016-08-01

    In conventional 4D positron emission tomography (4D-PET), images from different frames are reconstructed individually and aligned by registration methods. Two issues that arise with this approach are as follows: (1) the reconstruction algorithms do not make full use of projection statistics; and (2) the registration between noisy images can result in poor alignment. In this study, we investigated the use of simultaneous motion estimation and image reconstruction (SMEIR) methods for motion estimation/correction in 4D-PET. A modified ordered-subset expectation maximization algorithm coupled with total variation minimization (OSEM-TV) was used to obtain a primary motion-compensated PET (pmc-PET) from all projection data, using Demons derived deformation vector fields (DVFs) as initial motion vectors. A motion model update was performed to obtain an optimal set of DVFs in the pmc-PET and other phases, by matching the forward projection of the deformed pmc-PET with measured projections from other phases. The OSEM-TV image reconstruction was repeated using updated DVFs, and new DVFs were estimated based on updated images. A 4D-XCAT phantom with typical FDG biodistribution was generated to evaluate the performance of the SMEIR algorithm in lung and liver tumors with different contrasts and different diameters (10-40 mm). The image quality of the 4D-PET was greatly improved by the SMEIR algorithm. When all projections were used to reconstruct 3D-PET without motion compensation, motion blurring artifacts were present, leading up to 150% tumor size overestimation and significant quantitative errors, including 50% underestimation of tumor contrast and 59% underestimation of tumor uptake. Errors were reduced to less than 10% in most images by using the SMEIR algorithm, showing its potential in motion estimation/correction in 4D-PET.

  14. 17 CFR 260.4d-8 - Content.

    Code of Federal Regulations, 2010 CFR

    2011-04-01

    ... 17 Commodity and Securities Exchanges 3 2011-04-01 2011-04-01 false Content. 260.4d-8 Section 260.4d-8 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION (CONTINUED) GENERAL RULES AND REGULATIONS, TRUST INDENTURE ACT OF 1939 Rules Under Section 304 § 260.4d-8 Content. (a) Each...

  15. 17 CFR 260.4d-8 - Content.

    Code of Federal Regulations, 2010 CFR

    2012-04-01

    ... 17 Commodity and Securities Exchanges 3 2012-04-01 2012-04-01 false Content. 260.4d-8 Section 260.4d-8 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION (CONTINUED) GENERAL RULES AND REGULATIONS, TRUST INDENTURE ACT OF 1939 Rules Under Section 304 § 260.4d-8 Content. (a) Each...

  16. 17 CFR 260.4d-8 - Content.

    Code of Federal Regulations, 2010 CFR

    2005-04-01

    ... 17 Commodity and Securities Exchanges 3 2005-04-01 2005-04-01 false Content. 260.4d-8 Section 260.4d-8 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION (CONTINUED) GENERAL RULES AND REGULATIONS, TRUST INDENTURE ACT OF 1939 Rules Under Section 304 § 260.4d-8 Content. (a) Each...

  17. Finger length ratio (2D:4D) in adults with gender identity disorder.

    PubMed

    Kraemer, Bernd; Noll, Thomas; Delsignore, Aba; Milos, Gabriella; Schnyder, Ulrich; Hepp, Urs

    2009-06-01

    From early childhood, gender identity and the 2nd to 4th finger length ratio (2D:4D) are discriminative characteristics between sexes. Both the human brain and 2D:4D may be influenced by prenatal testosterone levels. This calls for an examination of 2D:4D in patients with gender identity disorder (GID) to study the possible influence of prenatal testosterone on gender identity. Until now, the only study carried out on this issue suggests lower prenatal testosterone levels in right-handed male-to-female GID patients (MtF). We compared 2D:4D of 56 GID patients (39 MtF; 17 female-to-male GID patients, FtM) with data from a control sample of 176 men and 190 women. Bivariate group comparisons showed that right hand 2D:4D in MtF was significantly higher (feminized) than in male controls, but similar to female controls. The comparison of 2D:4D ratios of biological women revealed significantly higher (feminized) values for right hands of right handed FtM. Analysis of variance confirmed significant effects for sex and for gender identity on 2D:4D ratios but not for sexual orientation or for the interaction among variables. Our results indirectly point to the possibility of a weak influence of reduced prenatal testosterone as an etiological factor in the multifactorially influenced development of MtF GID. The development of FtM GID seems even more unlikely to be notably influenced by prenatal testosterone.

  18. Rapid analysis of 2,4-D in soil samples by modified Soxhlet apparatus using HPLC with UV detection.

    PubMed

    Kashyap, Sanjay M; Pandya, Girish H; Kondawar, Vivek K; Gabhane, Sanjay S

    2005-02-01

    The 2,4-dichlorophenoxy acetic acid (2,4-D) is used as a systemic herbicide to control broadleaf weeds in wheat, corn, range land/pasture land, sorghum, and barley. In this study, a fast and efficient method is developed by selection of modified extraction apparatus and high-performance liquid chromatography (HPLC)-UV conditions for the determination of 2,4-D in soil samples. The method is applied to the study of soil samples collected from the agricultural field. The herbicide is extracted from soil samples by acetonitrile in a modified Soxhlet apparatus. The advantages of the apparatus are that it uses small volume of organic solvent, reduced time of extraction, and better recovery of the analyte. The extract is filtered using a very fine microfiber paper. The total extract is concentrated in a rotatory evaporator, dried under ultrahigh pure N2, and finally reconstituted in 1 mL of acetonitrile. HPLC-UV at 228 nm is used for analysis. The herbicide is identified and quantitated using the HPLC system. The method is validated by the analysis of spiked soil samples. Recoveries obtained varied from 85% to 100% for spiked soil samples. The limit of quantitation (LOQ) and the limit of detection (LOD) are 0.010 and 0.005 parts per million (ppm), respectively, for spiked soil samples. The LOQ and LOD are 0.006 and 0.003 ppm for unspiked soil samples. The measured concentrations of 2,4-D in spiked soil samples are between 0.010 and 0.020 ppm with an average of 0.016 +/- 0.003 ppm. For unspiked soil samples it is between 0.006 ppm and 0.012 ppm with an average of 0.009 +/- 0.002 ppm. The measured concentrations of 2,4-D in soil samples are generally low and do not exceed the regulatory agencies guidelines.

  19. Early outcomes of transcatheter aortic valve replacement in patients with severe aortic stenosis: single center experience

    PubMed Central

    Bozkurt, Engin; Keleş, Telat; Durmaz, Tahir; Akçay, Murat; Ayhan, Hüseyin; Bayram, Nihal Akar; Aslan, Abdullah Nabi; Baştuğ, Serdal; Bilen, Emine

    2014-01-01

    Introduction Transcatheter aortic valve implantation is a promising alternative to high risk surgical aortic valve replacement. The procedure is mainly indicated in patients with severe symptomatic aortic stenosis who cannot undergo surgery or who are at very high surgical risk. Aim Description early results of our single-center experience with balloon expandable aortic valve implantation. Material and methods Between July 2011 and August 2012, we screened in total 75 consecutive patients with severe aortic stenosis and high risk for surgery. Twenty-one of them were found ineligible for transcatheter aortic valve implantation (TAVI) because of various reasons, and finally we treated a total of 54 patients with symptomatic severe aortic stenosis (AS) who could not be treated by open heart surgery (inoperable) because of high-risk criteria. The average age of the patients was 77.4 ±7.1; 27.8% were male and 72.2% were female. The number of patients in NYHA class II was 7 while the number of patients in class III and class IV was 47. Results The average mortality score of patients according to the STS scoring system was 8.5%. Pre-implantation mean and maximal aortic valve gradients were measured as 53.2 ±14.1 mm Hg and 85.5 ±18.9 mm Hg, respectively. Post-implantation mean and maximal aortic valve gradients were 9.0 ±3.0 and 18.2 ±5.6, respectively (p < 0.0001). The left ventricular ejection fraction was calculated as 54.7 ±14.4% before the operation and 58.0 ±11.1% after the operation (p < 0.0001). The duration of discharge after the operation was 5.29 days, and a statistically significant correlation between the duration of discharge after the operation and STS was found (r = 0385, p = 0.004). Conclusions We consider that with decreasing cost and increasing treatment experience, TAVI will be used more frequently in broader indications. Our experience with TAVI using the Edwards-Sapien XT (Edwards Lifesciences, Irvine, CA) devices suggests that this is an

  20. Novel self-expandable, stent-based transcatheter pulmonic valve: a preclinical animal study.

    PubMed

    Kim, Gi Beom; Lim, Hong-Gook; Kim, Yong Jin; Choi, Eun Young; Kwon, Bo Sang; Jeong, Saeromi

    2014-04-15

    Because transcatheter implantation of pulmonary valve is indicated for limited-size dysfunctional right ventricular outflow tract only as a balloon-expandable stent, we investigated the feasibility of a large-diameter self-expandable valved stent and the durability of the valve after >6 months. We made a nitinol-wire-based, self-expandable valved stent with leaflets made from porcine pericardium. The porcine pericardium was treated with α-galactosidase, glutaraldehyde, and glycine after decellularization. After cutting the inguinal or cervical area, we implanted a valved stent in 12 sheep through the femoral or jugular vein by using an 18-Fr delivery catheter, controlling the catheter handles and hook block under fluoroscopic and echocardiographic guidance. The mean body weight of sheep was 43.9 kg. We successfully implanted valved stents (diameter: 24 mm in 7 sheep, 26 mm in 5 sheep) in good position in 8 sheep, in the main pulmonary artery (PA) in 2 sheep, and in the right ventricular outlet tract (RVOT) in 2 sheep. We sacrificed 8 sheep (6 sheep in good position, 1 sheep in the main PA, and 1 sheep in the RVOT) after >6 months. Five of the 6 sheep implanted in good position showed well-preserved valve morphology at the time of sacrifice. Histologic findings after routine sacrifice showed well-maintained collagen wave structure and no visible calcification in all explanted valve leaflets. Transcatheter implantation of a nitinol-wire-based, self-expandable valved stent in the pulmonic valve was feasible, and stents implanted in good position showed well-preserved valve leaflets with functional competence in the mid-term results. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  1. "Guidelines Recommendations on the Treatment of Tricuspid Regurgitation. Where Are We and Where Do We Go With Transcatheter Valve Intervention".

    PubMed

    Vahanian, Alec; Brochet, Eric; Juliard, Jean-Michel

    2018-01-01

    Tricuspid regurgitation (TR) is an important clinical problem because it is frequent and carries a poor prognosis when it is left uncorrected. However, there is still a lack of awareness of tricuspid disease in the medical community. The indications for evaluation and surgical interventions in patients with TR were recently updated in the ESC/EACTS guidelines. Transcatheter tricuspid valve intervention (TTVI), almost exclusively valve repair, is at an early stage of development as only a few hundreds of patients have been treated. The first-in-man valve implantation was very recently performed. The recent ESC/EACTS Guidelines state that "The potential role of transcatheter tricuspid valve treatment in high-risk patients needs to be determined". We shall review here which lessons of interest for TTVI can be learned from the Guidelines as regards evaluation and indications for surgery and try to imagine what could be the place of TTVI in the Guidelines in the future.

  2. Estimation of skeletal movement of human locomotion from body surface shapes using dynamic spatial video camera (DSVC) and 4D human model.

    PubMed

    Saito, Toshikuni; Suzuki, Naoki; Hattori, Asaki; Suzuki, Shigeyuki; Hayashibe, Mitsuhiro; Otake, Yoshito

    2006-01-01

    We have been developing a DSVC (Dynamic Spatial Video Camera) system to measure and observe human locomotion quantitatively and freely. A 4D (four-dimensional) human model with detailed skeletal structure, joint, muscle, and motor functionality has been built. The purpose of our research was to estimate skeletal movements from body surface shapes using DSVC and the 4D human model. For this purpose, we constructed a body surface model of a subject and resized the standard 4D human model to match with geometrical features of the subject's body surface model. Software that integrates the DSVC system and the 4D human model, and allows dynamic skeletal state analysis from body surface movement data was also developed. We practically applied the developed system in dynamic skeletal state analysis of a lower limb in motion and were able to visualize the motion using geometrically resized standard 4D human model.

  3. Relationships between digit ratio (2D:4D) and basketball performance in Australian men.

    PubMed

    Frick, Nathan A; Hull, Melissa J; Manning, John T; Tomkinson, Grant R

    2017-05-06

    To investigate relationships between the digit ratio (2D:4D) and competitive basketball performance in Australian men. Using an observational cross-sectional design a total of 221 Australian basketball players who competed in the Olympic Games, International Basketball Federation World Championships/Cup, Australian National Basketball League, Central Australian Basketball League or socially had their 2D:4Ds measured. Analysis of variance was used to assess differences in mean 2D:4Ds between men playing at different competitive standards, with relationships between 2D:4Ds and basketball game-related statistics assessed using Pearson's product moment correlations in men playing at a single competitive standard. There were significant differences between competitive standards for the left 2D:4D following Bonferroni correction, but not for the right 2D:4D, with basketballers who achieved higher competitive standards tending to have lower left 2D:4Ds. No important correlations between 2D:4D and basketball game-related statistics were found, with correlations typically negligible. This study indicated that the 2D:4D can discriminate between basketballers competing at different standards, but not between basketballers within a single competitive standard using objective game-related statistics. © 2016 Wiley Periodicals, Inc.

  4. Low 2D:4D Values Are Associated with Video Game Addiction

    PubMed Central

    Kornhuber, Johannes; Zenses, Eva-Maria; Lenz, Bernd; Stoessel, Christina; Bouna-Pyrrou, Polyxeni; Rehbein, Florian; Kliem, Sören; Mößle, Thomas

    2013-01-01

    Androgen-dependent signaling regulates the growth of the fingers on the human hand during embryogenesis. A higher androgen load results in lower 2D:4D (second digit to fourth digit) ratio values. Prenatal androgen exposure also impacts brain development. 2D:4D values are usually lower in males and are viewed as a proxy of male brain organization. Here, we quantified video gaming behavior in young males. We found lower mean 2D:4D values in subjects who were classified according to the CSAS-II as having at-risk/addicted behavior (n = 27) compared with individuals with unproblematic video gaming behavior (n = 27). Thus, prenatal androgen exposure and a hyper-male brain organization, as represented by low 2D:4D values, are associated with problematic video gaming behavior. These results may be used to improve the diagnosis, prediction, and prevention of video game addiction. PMID:24236143

  5. Investigating fold structures of 2D materials by quantitative transmission electron microscopy.

    PubMed

    Wang, Zhiwei; Zhang, Zengming; Liu, Wei; Wang, Zhong Lin

    2017-04-01

    We report an approach developed for deriving 3D structural information of 2D membrane folds based on the recently-established quantitative transmission electron microscopy (TEM) in combination with density functional theory (DFT) calculations. Systematic multislice simulations reveal that the membrane folding leads to sufficiently strong electron scattering which enables a precise determination of bending radius. The image contrast depends also on the folding angles of 2D materials due to the variation of projection potentials, which however exerts much smaller effect compared with the bending radii. DFT calculations show that folded edges are typically characteristic of (fractional) nanotubes with the same curvature retained after energy optimization. Owing to the exclusion of Stobbs factor issue, numerical simulations were directly used in comparison with the experimental measurements on an absolute contrast scale, which results in a successful determination of bending radius of folded monolayer MoS 2 films. The method should be applicable to characterizing all 2D membranes with 3D folding features. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Direct determination of phosphorylated intracellular anabolites of stavudine (d4T) by liquid chromatography/tandem mass spectrometry.

    PubMed

    Pruvost, A; Becher, F; Bardouille, P; Guerrero, C; Creminon, C; Delfraissy, J F; Goujard, C; Grassi, J; Benech, H

    2001-01-01

    The objective was to develop and validate a routine assay for active intracellular anabolites of stavudine (d4T), a nucleoside reverse transcriptase inhibitor in human PBMC, applicable to pharmacokinetic studies and treatment monitoring. This was achieved using liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS), which theoretically allies optimum sensitivity, specificity and high sample throughput. After cellular lysis in a Tris/methanol buffer, the extract spiked with 2[H(8)]-ATP (internal standard) is directly injected into the LC/MS/MS system. Phosphorylated metabolites of d4T as well as deoxythymidine-triphosphate, the competitor on the reverse transcriptase, are separated from d4T on a reverse-phase microbore column with ion pairing. The detection is performed in the multiple reaction monitoring (MRM) mode after drug ionisation in negative mode electrospray. The limit of quantitation for d4T-TP was 138 fmol per 7 mL blood (9.8 fmol per 10(6) cells) and CV% for repeatability and intermediate precision were lower than 15%. Stability of compounds was checked before and during the process of isolation of PBMC. Cellular samples from several d4T-treated patients were successfully analysed using this method and d4T-triphosphate and deoxythymidine triphosphate were recovered. In conclusion, we have developed and validated a routine LC/MS/MS method that allows the simultaneous determination of mono-, di- and triphosphorylated anabolites of d4T in PBMC as well as the natural corresponding triphosphate in one analysis. For the first time, the chain terminator ratio (d4T-TP/dT-TP) could be directly measured. This method can be used simply and routinely on more than 35 samples per day. Extension to other nucleoside analogues is under development. Copyright 2001 John Wiley & Sons, Ltd.

  7. The association between renal recovery after acute kidney injury and long-term mortality after transcatheter aortic valve replacement.

    PubMed

    Thongprayoon, Charat; Cheungpasitporn, Wisit; Srivali, Narat; Kittanamongkolchai, Wonngarm; Sakhuja, Ankit; Greason, Kevin L; Kashani, Kianoush B

    2017-01-01

    This study aimed to examine the association between renal recovery status at hospital discharge after acute kidney injury (AKI) and long-term mortality following transcatheter aortic valve replacement (TAVR). We screened all adult patients who survived to hospital discharge after TAVR for aortic stenosis at a quaternary referral medical center from January 1, 2008, through June 30, 2014. An AKI was defined as an increase in serum creatinine level of 0.3 mg/dL or a relative increase of 50% from baseline. Renal outcome at the time of discharge was evaluated by comparing the discharge serum creatinine level to the baseline level. Complete renal recovery was defined as no AKI at discharge, whereas partial renal recovery was defined as AKI without a need for renal replacement therapy at discharge. No renal recovery was defined as a need for renal replacement therapy at discharge. The study included 374 patients. Ninty-eight (26%) patients developed AKI during hospitalization: 55 (56%) had complete recovery; 39 (40%), partial recovery; and 4 (4%), no recovery. AKI development was significantly associated with increased risk of 2-year mortality (hazard ratio [HR], 2.20 [95% CI, 1.37-3.49]). For patients with AKI, the 2-year mortality rate for complete recovery was 34%; for partial recovery, 43%; and for no recovery, 75%; compared with 20% for patients without AKI (P < .001). In adjusted analysis, complete recovery (HR, 1.87 [95% CI, 1.03-3.23]); partial recovery (HR, 2.65 [95% CI, 1.40-4.71]) and no recovery (HR, 10.95 [95% CI, 2.59-31.49]) after AKI vs no AKI were significantly associated with increased risk of 2-year mortality. The mortality rate increased for all patients with AKI undergoing TAVR. A reverse correlation existed for progressively higher risk of death and the extent of AKI recovery.

  8. Prospective evaluation of the feasibility, safety, and efficacy of Cocoon Duct Occluder for transcatheter closure of large patent ductus arteriosus: A single-center study with short- and medium-term follow-up results

    PubMed Central

    Sinha, Santosh Kumar; Razi, Mahmadula; Pandey, Rama Niwas; Kumar, Prakash; Krishna, Vinay; Jha, Mukesh Jitendra; Mishra, Vikas; Asif, Mohammad; Abdali, Nasar; Tewari, Pradyot; Thakur, Ramesh; Pandey, Umeshwar; Varma, Chandra Mohan

    2017-01-01

    Objective: To evaluate the feasibility, safety, and efficacy of a novel Cocoon Duct Occluder device for the transcatheter closure (TCC) of large patent ductus arteriosus (PDA). Methods: In this prospective, non-randomized study, consecutive patients with large PDA (narrowest diameter: ≥3.5/4.0 mm in symptomatic/asymptomatic patients, respectively), who underwent TCC with Cocoon Duct Occluder at our institute between November, 2012 and June, 2016 were examined. TCC was performed using the standard technique, and devices were antegradely delivered via 6–10F delivery sheaths. Device embolization, residual shunt, hemolysis, left pulmonary artery (LPA) stenosis, procedural and fluoroscopy time, and mortality were assessed. Patients were followed-up by transthoracic echocardiography with color Doppler imaging at 24 h (D1), 1 month (D30), and 6 months (D180) after implantation. Results: A total of 57 patients (age: 11.7±2.8 years; weight: 22.3±3.5 kg) were enrolled. The mean narrowest diameter was 7.4±0.7 mm. The PDA closure was successfully performed in each patient. Fluoroscopy and procedural time was 6.7±3.2 min and 23.9±2.7 min, respectively. Postprocedural angiography revealed that 49 (85.9%) patients had immediate and complete closure, whereas 8 (14.1%) had residual shunt. Color Doppler imaging at D1 revealed complete closure in 52 (91.3%) patients. At D30, complete closure was reported in all patients and was maintained at D180. Hemolysis, embolization, obstruction of LPA or descending aorta, and death were not reported till D180. Conclusion: TCC using Cocoon Duct Occluder is feasible, safe, and effective in the management of patients with large PDA, with excellent results on short- and medium-term follow-up. PMID:29145233

  9. [Transcatheter aortic valve implantation for aortic stenosis. Initial experience].

    PubMed

    Careaga-Reyna, Guillermo; Lázaro-Castillo, José Luis; Lezama-Urtecho, Carlos Alberto; Macías-Miranda, Enriqueta; Dosta-Herrera, Juan José; Galván Díaz, José

    Aortic stenosis is a frequent disease in the elderly, and is associated with other systemic pathologies that may contraindicate the surgical procedure. Another option for these patients is percutaneous aortic valve implantation, which is less invasive. We present our initial experience with this procedure. Patients with aortic stenosis were included once selection criteria were accomplished. Under general anaesthesia and echocardiographic and fluosocopic control, a transcatheter aortic valve was implanted following s valvuloplasty. Once concluded the procedure, angiographic and pressure control was realized in order to confirm the valve function. Between November 2014 and May 2015, 6 patients were treated (4 males and 2 females), with a mean age of 78.83±5.66 years-old. The preoperative transvalvular gradient was 90.16±28.53mmHg and posterior to valve implant was 3.33±2.92mmHg (P<.05). Two patients had concomitant coronary artery disease which had been treated previously. One patient presented with acute right coronary artery occlusion which was immediately treated. However due to previous renal failure, postoperative sepsis and respiratory failure, the patient died one month later. It was concluded that our preliminary results showed that in selected patients percutaneous aortic valve implantation is a safe procedure with clinical improvement for treated patients. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  10. Transcatheter Embolization of a Renal Artery Aneurysm Using Ethylene Vinyl Alcohol Copolymer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rautio, Riitta, E-mail: riitta.rautio@tyks.fi; Haapanen, Arto

    2007-04-15

    Our aim was to treat a clinically silent renal artery aneurysm. The patient was a 76-year-old man with elevated prostate-specific antigen and prostata biopsies with a gradus II-III adenocarcinoma who was incidentally found to have an aneurysm in his right renal artery. We performed a successful transcatheter embolization of the aneurysm using ethylene vinyl alcohol copolymer (Onyx). To avoid migration of the liquid material into the parent artery, a balloon was inflated in the orifice of the neck of the aneurysm while the liquid was injected. Five-month follow-up computed tomography (CT) imaging confirmed total occlusion of the aneurysm.

  11. D 6ℛ4 amplitudes in various dimensions

    NASA Astrophysics Data System (ADS)

    Pioline, Boris

    2015-04-01

    Four-graviton couplings in the low energy effective action of type II string vacua compactified on tori are strongly constrained by supersymmetry and U-duality. While the ℛ4 and D 44 couplings are known exactly in terms of Langlands-Eisenstein series of the U-duality group, the D 6ℛ4 couplings are not nearly as well understood. Exploiting the coincidence of the U-duality group in D = 6 with the T-duality group in D = 5, we propose an exact formula for the D 6ℛ4 couplings in type II string theory compactified on T 4, in terms of a genus-two modular integral plus a suitable Eisenstein series. The same modular integral computes the two-loop correction to D 6ℛ4 in 5 dimensions, but here provides the non-perturbative completion of the known perturbative terms in D = 6. This proposal hinges on a systematic re-analysis of the weak coupling and large radius of the D 6ℛ4 in all dimensions D ≥ 3, which fills in some gaps and resolves some inconsistencies in earlier studies.

  12. The discovery of novel histone lysine methyltransferase G9a inhibitors (part 1): molecular design based on a series of substituted 2,4-diamino-7- aminoalkoxyquinazoline by molecular-docking-guided 3D quantitative structure-activity relationship studies.

    PubMed

    Feng, Taotao; Wang, Hai; Zhang, Xiaojin; Sun, Haopeng; You, Qidong

    2014-06-01

    Protein lysine methyltransferase G9a, which catalyzes methylation of lysine 9 of histone H3 (H3K9) and lysine 373 (K373) of p53, is overexpressed in human cancers. This suggests that small molecular inhibitors of G9a might be attractive antitumor agents. Herein we report our efforts on the design of novel G9a inhibitor based on the 3D quantitative structure-activity relationship (3D-QSAR) analysis of a series of 2,4-diamino-7-aminoalkoxyquinazolineas G9a inhibitors. The 3D-QSAR model was generated from 47 compounds using docking based molecular alignment. The best predictions were obtained with CoMFA standard model (q2 =0.700, r2 = 0.952) and CoMSIA model combined with steric, electrostatic, hydrophobic, hydrogen bond donor and acceptor fields (q2 = 0.724, r2 =0.960). The structural requirements for substituted 2,4-diamino-7-aminoalkoxyquinazoline for G9a inhibitory activity can be obtained by analysing the COMSIA plots. Based on the information, six novel follow-up analogs were designed.

  13. Physical modeling of 3D and 4D laser imaging

    NASA Astrophysics Data System (ADS)

    Anna, Guillaume; Hamoir, Dominique; Hespel, Laurent; Lafay, Fabien; Rivière, Nicolas; Tanguy, Bernard

    2010-04-01

    Laser imaging offers potential for observation, for 3D terrain-mapping and classification as well as for target identification, including behind vegetation, camouflage or glass windows, at day and night, and under all-weather conditions. First generation systems deliver 3D point clouds. The threshold detection is largely affected by the local opto-geometric characteristics of the objects, leading to inaccuracies in the distances measured, and by partial occultation, leading to multiple echos. Second generation systems circumvent these limitations by recording the temporal waveforms received by the system, so that data processing can improve the telemetry and the point cloud better match the reality. Future algorithms may exploit the full potential of the 4D full-waveform data. Hence, being able to simulate point-cloud (3D) and full-waveform (4D) laser imaging is key. We have developped a numerical model for predicting the output data of 3D or 4D laser imagers. The model does account for the temporal and transverse characteristics of the laser pulse (i.e. of the "laser bullet") emitted by the system, its propagation through turbulent and scattering atmosphere, its interaction with the objects present in the field of view, and the characteristics of the optoelectronic reception path of the system.

  14. Post-stenotic plug-like jet with a vortex ring demonstrated by 4D flow MRI.

    PubMed

    Kim, Guk Bae; Ha, Hojin; Kweon, Jihoon; Lee, Sang Joon; Kim, Young-Hak; Yang, Dong Hyun; Kim, Namkug

    2016-05-01

    To investigate the details of the flow structure of a plug-like jet that had a vortex ring in pulsatile stenotic phantoms using 4D flow MRI. Pulsatile Newtonian flows in two stenotic phantoms with 50% and 75% reductions in area were scanned by 4D flow MRI. Blood analog working fluid was circulated via the stenotic phantom using a pulsatile pump at a constant pulsating frequency of 1Hz. The velocity and vorticity fields of the plug-like jet with a vortex ring were quantitatively analyzed in the spatial and temporal domains. Pulsatile stenotic flow showed a plug-like jet at the specific stenotic degree of 50% in our pulsatile waveform design. This plug-like jet was found at the decelerating period in the post-stenotic region of 26.4mm (1.2 D). It revealed a vortex ring structure with vorticity strength in the range of ±100s(-1). We observed a plug-like jet with a vortex ring in pulsatile stenotic flow by in vitro visualization using 4D flow MRI. In this plug-like jet, the local fastest flow region occurred at the post-systole phase in the post-stenotic region, which was distinguishable from a typical stenotic jet flow at systole phase. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Oscillator strengths and branching fractions of 4d75p-4d75s Rh II transitions

    NASA Astrophysics Data System (ADS)

    Bouazza, Safa

    2017-01-01

    This work reports semi-empirical determination of oscillator strengths, transition probabilities and branching fractions for Rh II 4d75p-4d75s transitions in a wide wavelength range. The angular coefficients of the transition matrix, beforehand obtained in pure SL coupling with help of Racah algebra are transformed into intermediate coupling using eigenvector amplitudes of these two configuration levels determined for this purpose; The transition integral was treated as free parameter in the least squares fit to experimental oscillator strength (gf) values found in literature. The extracted value: <4d75s|r1|4d75p> =2.7426 ± 0.0007 is slightly smaller than that computed by means of ab-initio method. Subsequently to oscillator strength evaluations, transition probabilities and branching fractions were deduced and compared to those obtained experimentally or through another approach like pseudo-relativistic Hartree-Fock model including core-polarization effects.

  16. A capacitive sensor for 2,4-D determination in water based on 2,4-D imprinted polypyrrole coated pencil electrode

    NASA Astrophysics Data System (ADS)

    Prusty, Arun Kumar; Bhand, Sunil

    2017-03-01

    A capacitive sensor for 2,4-dichloro phenoxy acetic acid(2,4-D) determination in drinking water has been developed using molecularly imprinted polypyrrole on pencil graphite electrode (PGE). Molecular imprinted polymer (MIP) coated PGE was prepared by electropolymerization of pyrrole via chronopotentiometry in the presence of 2,4-D as the template molecule. The prepared electrodes were characterized by field emission gun-scanning electron microscopy, cyclic voltammetry, and electrochemical impedance spectroscopy (EIS). The capacitance change of MIP electrode was measured in the presence of 2,4-D using EIS. The developed capacitive sensor exhibited a linear range 0.06-1.25 µg l-1 2,4-D with limit of detection of 0.02 µg l-1 and good selectivity towards 2,4-D in water with recovery from 92 to 110%. The results suggest the viable applicability of the MIP/PGE based sensor for the determination of the 2,4-D in water samples.

  17. Pros and cons of transcatheter aortic valve implantation (TAVI)

    PubMed Central

    Terré, Juan A.; George, Isaac

    2017-01-01

    Transcatheter aortic valve implantation (TAVI) or replacement (TAVR) was recently approved by the FDA for intermediate risk patients with severe aortic stenosis (AS). This technique was already worldwide adopted for inoperable and high-risk patients. Improved device technology, imaging analysis and operator expertise has reduced the initial worrisome higher complications rate associated with TAVR, making it comparable to surgical aortic valve replacement (SAVR). However, many answers need to be addressed before adoption in lower risk patients. This paper highlights the pros and cons of TAVI based mostly on randomized clinical trials involving the two device platforms approved in the United States. We focused our analysis on metrics that will play a key role in expanding TAVR indication in healthier individuals. We review the significance and gave a perspective on paravalvular leak (PVL), valve performance, valve durability, leaflet thrombosis, stroke and pacemaker requirement. PMID:29062739

  18. Transcatheter treatment of life-threatening lower gastrointestinal bleeding due to advanced pelvic malignancy.

    PubMed

    Spinosa, D J; Angle, J F; McGraw, J K; Maurer, E J; Hagspiel, K D; Matsumoto, A H

    1998-01-01

    We present two patients with life-threatening, massive, lower gastrointestinal (GI) bleeding and locally advanced cervical carcinoma. Selective pelvic arteriography demonstrated that the site of bleeding originated from a pseudoaneurysm of the right internal iliac artery with fistulous communication to the sigmoid colon in one patient and from the left internal iliac artery into the rectum in the second patient. Transcatheter embolotherapy was then performed using balloon occlusion in one patient and coil embolization in the second patient. The iliac arteries should also be evaluated in patients with pelvic cancer who present with lower GI bleeding.

  19. SU-E-T-790: Validation of 4D Measurement-Guided Dose Reconstruction (MGDR) with OCTAVIUS 4D System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, V; Leung, R; Wong, M

    2015-06-15

    Purpose: To validate the MGDR of OCTAVIUS 4D system (PTW, Freiburg, Germany) for quality assurance (QA) of volumetric-modulated arc radiotherapy (VMAT). Methods: 4D-MGDR measurements were divided into two parts: 1) square fields from 2×2 to 25×25 cm{sup 2} at 0°, 10° and 45° gantry, and 2) 8 VMAT plans (5 nasopharyngeal and 3 prostate) collapsed to gantry 40° in QA mode in Monaco v5.0 (Elekta, CMS, Maryland Heights, MO) were delivered on the OCTAVIUS 4D phantom with the OCTAVIUS 1500 detector plane perpendicular to either the incident beam to obtain the reconstructed dose (OCTA4D) or the 0° gantry axis tomore » obtain the raw doses (OCTA3D) in Verisoft 6.1 (PTW, Freiburg, Germany). Raw measurements of OCTA3D were limited to < 45° gantry to avoid >0.5% variation of detector angular response with respect to 0° gantry as determined previously. Reconstructed OCTA4D and raw OCTA3D doses for all plans were compared at the same detector plane using γ criteria of 2% (local dose)/2mm and 3%/3mm criteria. Results: At gantry 0° and 10°, the γ results for all OCTA4D on detector plane coinciding with OCTA3D were over 90% at 2%/2mm except for the largest field (25×25 cm{sup 2} ) showing >88%. For square field at 45° gantry, γ passing rate is > 90% for fields smaller than 15x 15cm2 but < 80% for field size of 20 x20 cm{sup 2} upward. For VMAT, γ results showed 94% and 99% passing rate at 2%/2mm and 3%/3mm, respectively. Conclusion: OCTAVIUS 4D system has compromised accuracy in reconstructing dose away from the central beam axis, possibly due to the off-axis softening correction and errors of the percent depth dose data necessary as input for MGDR. Good results in VMAT delivery suggested that the system is relatively reliable for VMAT with small segments.« less

  20. Using 2D: 4D digit ratios to determine motor skills in children.

    PubMed

    Wang, Y; Wang, H-L; Li, Y-H; Zhu, F-L; Li, S-J; Ni, H

    2016-03-01

    In past few decades, there has an outburst of research surrounding second to fourth finger digit ratio (2D:4D) and its relation to prenatal sex steroids including both testosterone and estrogen. In utero, testosterone and estrogen are responsible for the differences in digit ratio between the genders. Recent research has tried to extend past the influence of steroids and look at the potential effect of digit ratios on fine and gross motor skills in children. We compiled the current understanding of the connection between sex hormones and the development of the 2D:4D ratio as well as the effect the ratio has on motor skills. There seems to be a significant positive correlation between 2D:4D digit ratio and precision of fine motor skill. In addition, there is a negative correlation between 2D:4D ratio and speed of fine motor activity. In this review, we will outline the use of 2D:4D ratio as a biomarker for prenatal sex steroids and through that, a proxy marker for fine and gross motor skills.

  1. Statistical modeling of 4D respiratory lung motion using diffeomorphic image registration.

    PubMed

    Ehrhardt, Jan; Werner, René; Schmidt-Richberg, Alexander; Handels, Heinz

    2011-02-01

    Modeling of respiratory motion has become increasingly important in various applications of medical imaging (e.g., radiation therapy of lung cancer). Current modeling approaches are usually confined to intra-patient registration of 3D image data representing the individual patient's anatomy at different breathing phases. We propose an approach to generate a mean motion model of the lung based on thoracic 4D computed tomography (CT) data of different patients to extend the motion modeling capabilities. Our modeling process consists of three steps: an intra-subject registration to generate subject-specific motion models, the generation of an average shape and intensity atlas of the lung as anatomical reference frame, and the registration of the subject-specific motion models to the atlas in order to build a statistical 4D mean motion model (4D-MMM). Furthermore, we present methods to adapt the 4D mean motion model to a patient-specific lung geometry. In all steps, a symmetric diffeomorphic nonlinear intensity-based registration method was employed. The Log-Euclidean framework was used to compute statistics on the diffeomorphic transformations. The presented methods are then used to build a mean motion model of respiratory lung motion using thoracic 4D CT data sets of 17 patients. We evaluate the model by applying it for estimating respiratory motion of ten lung cancer patients. The prediction is evaluated with respect to landmark and tumor motion, and the quantitative analysis results in a mean target registration error (TRE) of 3.3 ±1.6 mm if lung dynamics are not impaired by large lung tumors or other lung disorders (e.g., emphysema). With regard to lung tumor motion, we show that prediction accuracy is independent of tumor size and tumor motion amplitude in the considered data set. However, tumors adhering to non-lung structures degrade local lung dynamics significantly and the model-based prediction accuracy is lower in these cases. The statistical respiratory

  2. Abdominal 4D flow MR imaging in a breath hold: combination of spiral sampling and dynamic compressed sensing for highly accelerated acquisition.

    PubMed

    Dyvorne, Hadrien; Knight-Greenfield, Ashley; Jajamovich, Guido; Besa, Cecilia; Cui, Yong; Stalder, Aurélien; Markl, Michael; Taouli, Bachir

    2015-04-01

    To develop a highly accelerated phase-contrast cardiac-gated volume flow measurement (four-dimensional [4D] flow) magnetic resonance (MR) imaging technique based on spiral sampling and dynamic compressed sensing and to compare this technique with established phase-contrast imaging techniques for the quantification of blood flow in abdominal vessels. This single-center prospective study was compliant with HIPAA and approved by the institutional review board. Ten subjects (nine men, one woman; mean age, 51 years; age range, 30-70 years) were enrolled. Seven patients had liver disease. Written informed consent was obtained from all participants. Two 4D flow acquisitions were performed in each subject, one with use of Cartesian sampling with respiratory tracking and the other with use of spiral sampling and a breath hold. Cartesian two-dimensional (2D) cine phase-contrast images were also acquired in the portal vein. Two observers independently assessed vessel conspicuity on phase-contrast three-dimensional angiograms. Quantitative flow parameters were measured by two independent observers in major abdominal vessels. Intertechnique concordance was quantified by using Bland-Altman and logistic regression analyses. There was moderate to substantial agreement in vessel conspicuity between 4D flow acquisitions in arteries and veins (κ = 0.71 and 0.61, respectively, for observer 1; κ = 0.71 and 0.44 for observer 2), whereas more artifacts were observed with spiral 4D flow (κ = 0.30 and 0.20). Quantitative measurements in abdominal vessels showed good equivalence between spiral and Cartesian 4D flow techniques (lower bound of the 95% confidence interval: 63%, 77%, 60%, and 64% for flow, area, average velocity, and peak velocity, respectively). For portal venous flow, spiral 4D flow was in better agreement with 2D cine phase-contrast flow (95% limits of agreement: -8.8 and 9.3 mL/sec, respectively) than was Cartesian 4D flow (95% limits of agreement: -10.6 and 14.6 m

  3. VIPAR, a quantitative approach to 3D histopathology applied to lymphatic malformations

    PubMed Central

    Hägerling, René; Drees, Dominik; Scherzinger, Aaron; Dierkes, Cathrin; Martin-Almedina, Silvia; Butz, Stefan; Gordon, Kristiana; Schäfers, Michael; Hinrichs, Klaus; Vestweber, Dietmar; Goerge, Tobias; Mansour, Sahar; Mortimer, Peter S.

    2017-01-01

    BACKGROUND. Lack of investigatory and diagnostic tools has been a major contributing factor to the failure to mechanistically understand lymphedema and other lymphatic disorders in order to develop effective drug and surgical therapies. One difficulty has been understanding the true changes in lymph vessel pathology from standard 2D tissue sections. METHODS. VIPAR (volume information-based histopathological analysis by 3D reconstruction and data extraction), a light-sheet microscopy–based approach for the analysis of tissue biopsies, is based on digital reconstruction and visualization of microscopic image stacks. VIPAR allows semiautomated segmentation of the vasculature and subsequent nonbiased extraction of characteristic vessel shape and connectivity parameters. We applied VIPAR to analyze biopsies from healthy lymphedematous and lymphangiomatous skin. RESULTS. Digital 3D reconstruction provided a directly visually interpretable, comprehensive representation of the lymphatic and blood vessels in the analyzed tissue volumes. The most conspicuous features were disrupted lymphatic vessels in lymphedematous skin and a hyperplasia (4.36-fold lymphatic vessel volume increase) in the lymphangiomatous skin. Both abnormalities were detected by the connectivity analysis based on extracted vessel shape and structure data. The quantitative evaluation of extracted data revealed a significant reduction of lymphatic segment length (51.3% and 54.2%) and straightness (89.2% and 83.7%) for lymphedematous and lymphangiomatous skin, respectively. Blood vessel length was significantly increased in the lymphangiomatous sample (239.3%). CONCLUSION. VIPAR is a volume-based tissue reconstruction data extraction and analysis approach that successfully distinguished healthy from lymphedematous and lymphangiomatous skin. Its application is not limited to the vascular systems or skin. FUNDING. Max Planck Society, DFG (SFB 656), and Cells-in-Motion Cluster of Excellence EXC 1003. PMID

  4. VIPAR, a quantitative approach to 3D histopathology applied to lymphatic malformations.

    PubMed

    Hägerling, René; Drees, Dominik; Scherzinger, Aaron; Dierkes, Cathrin; Martin-Almedina, Silvia; Butz, Stefan; Gordon, Kristiana; Schäfers, Michael; Hinrichs, Klaus; Ostergaard, Pia; Vestweber, Dietmar; Goerge, Tobias; Mansour, Sahar; Jiang, Xiaoyi; Mortimer, Peter S; Kiefer, Friedemann

    2017-08-17

    Lack of investigatory and diagnostic tools has been a major contributing factor to the failure to mechanistically understand lymphedema and other lymphatic disorders in order to develop effective drug and surgical therapies. One difficulty has been understanding the true changes in lymph vessel pathology from standard 2D tissue sections. VIPAR (volume information-based histopathological analysis by 3D reconstruction and data extraction), a light-sheet microscopy-based approach for the analysis of tissue biopsies, is based on digital reconstruction and visualization of microscopic image stacks. VIPAR allows semiautomated segmentation of the vasculature and subsequent nonbiased extraction of characteristic vessel shape and connectivity parameters. We applied VIPAR to analyze biopsies from healthy lymphedematous and lymphangiomatous skin. Digital 3D reconstruction provided a directly visually interpretable, comprehensive representation of the lymphatic and blood vessels in the analyzed tissue volumes. The most conspicuous features were disrupted lymphatic vessels in lymphedematous skin and a hyperplasia (4.36-fold lymphatic vessel volume increase) in the lymphangiomatous skin. Both abnormalities were detected by the connectivity analysis based on extracted vessel shape and structure data. The quantitative evaluation of extracted data revealed a significant reduction of lymphatic segment length (51.3% and 54.2%) and straightness (89.2% and 83.7%) for lymphedematous and lymphangiomatous skin, respectively. Blood vessel length was significantly increased in the lymphangiomatous sample (239.3%). VIPAR is a volume-based tissue reconstruction data extraction and analysis approach that successfully distinguished healthy from lymphedematous and lymphangiomatous skin. Its application is not limited to the vascular systems or skin. Max Planck Society, DFG (SFB 656), and Cells-in-Motion Cluster of Excellence EXC 1003.

  5. On the relation between 2D:4D and sex-dimorphic personality traits.

    PubMed

    Hampson, Elizabeth; Ellis, Connie L; Tenk, Christine M

    2008-02-01

    Several personality traits, including aggressiveness and sensation seeking, have been hypothesized to be influenced by prenatal androgen exposure, though evidence for this proposition is limited. We investigated whether individual differences in aggressiveness, sensation seeking, and several prosocial personality traits can be predicted from differences in the 2D:4D digit ratio, a putative marker of prenatal androgen activity. A total of 164 undergraduates (87 men, 77 women) completed self-report measures of physical and verbal aggression, as well as a standardized measure of sensation seeking, and five scales to assess empathy, nurturance, expressivity/femininity, instrumentality/masculinity, and assertiveness. Two sex-dimorphic tests of spatial ability also were included. Men had a lower 2D:4D ratio than women, confirming the typical sex difference in digit proportions. Significant sex differences were observed on 10 of the 11 personality scales purported to show sex differences and on both tests of spatial ability. The 2D:4D ratio was a significant predictor of scores on three of the four aggression subscales, total aggression, thrill and adventure seeking, and total sensation-seeking, in the sample as a whole and in women. In men, correlations with 2D:4D were significant only for total sensation-seeking and verbal aggression. In both sexes, lower 2D:4D ratios were associated with increased aggressiveness and sensation seeking. For the spatial tests, there was no evidence of any association with 2D:4D in either men or women. The 2D:4D digit ratio may be a valid, though weak, predictor of selective sex-dependent traits that are sensitive to testosterone.

  6. Leukotriene B4 catabolism: quantitation of leukotriene B4 and its omega-oxidation products by reversed-phase high-performance liquid chromatography.

    PubMed

    Shak, S

    1987-01-01

    LTB4 and its omega-oxidation products may be rapidly, sensitively, and specifically quantitated by the methods of solid-phase extraction and reversed-phase high-performance liquid chromatography (HPLC), which are described in this chapter. Although other techniques, such as radioimmunoassay or gas chromatography-mass spectrometry, may be utilized for quantitative analysis of the lipoxygenase products of arachidonic acid, only the technique of reversed-phase HPLC can quantitate as many as 10 metabolites in a single analysis, without prior derivatization. In this chapter, we also reviewed the chromatographic theory which we utilized in order to optimize reversed-phase HPLC analysis of LTB4 and its omega-oxidation products. With this information and a gradient HPLC system, it is possible for any investigator to develop a powerful assay for the potent inflammatory mediator, LTB4, or for any other lipoxygenase product of arachidonic acid.

  7. Direct 4D reconstruction of parametric images incorporating anato-functional joint entropy.

    PubMed

    Tang, Jing; Kuwabara, Hiroto; Wong, Dean F; Rahmim, Arman

    2010-08-07

    We developed an anatomy-guided 4D closed-form algorithm to directly reconstruct parametric images from projection data for (nearly) irreversible tracers. Conventional methods consist of individually reconstructing 2D/3D PET data, followed by graphical analysis on the sequence of reconstructed image frames. The proposed direct reconstruction approach maintains the simplicity and accuracy of the expectation-maximization (EM) algorithm by extending the system matrix to include the relation between the parametric images and the measured data. A closed-form solution was achieved using a different hidden complete-data formulation within the EM framework. Furthermore, the proposed method was extended to maximum a posterior reconstruction via incorporation of MR image information, taking the joint entropy between MR and parametric PET features as the prior. Using realistic simulated noisy [(11)C]-naltrindole PET and MR brain images/data, the quantitative performance of the proposed methods was investigated. Significant improvements in terms of noise versus bias performance were demonstrated when performing direct parametric reconstruction, and additionally upon extending the algorithm to its Bayesian counterpart using the MR-PET joint entropy measure.

  8. Transcatheter arterial embolization for endoscopically unmanageable non-variceal upper gastrointestinal bleeding.

    PubMed

    Lee, Han Hee; Park, Jae Myung; Chun, Ho Jong; Oh, Jung Suk; Ahn, Hyo Jun; Choi, Myung-Gyu

    2015-07-01

    Transcatheter arterial embolization (TAE) is a therapeutic option for endoscopically unmanageable upper gastrointestinal (GI) bleeding. We aimed to assess the efficacy and clinical outcomes of TAE for acute non-variceal upper GI bleeding and to identify predictors of recurrent bleeding within 30 days. Visceral angiography was performed in 66 patients (42 men, 24 women; mean age, 60.3 ± 12.7 years) who experienced acute non-variceal upper GI bleeding that failed to be controlled by endoscopy during a 7-year period. Clinical information was reviewed retrospectively. Outcomes included technical success rates, complications, and 30-day rebleeding and mortality rates. TAE was feasible in 59 patients. The technical success rate was 98%. Rebleeding within 30 days was observed in 47% after an initial TAE and was managed with re-embolization in 8, by endoscopic intervention in 5, by surgery in 2, and by conservative care in 12 patients. The 30-day overall mortality rate was 42.4%. In the case of initial endoscopic hemostasis failure (n = 34), 31 patients underwent angiographic embolization, which was successful in 30 patients (96.8%). Rebleeding occurred in 15 patients (50%), mainly because of malignancy. Two factors were independent predictors of rebleeding within 30 days by multivariate analysis: coagulopathy (odds ratio [OR] = 4.37; 95% confidence interval [CI]: 1.25-15.29; p = 0.021) and embolization in ≥2 territories (OR = 4.93; 95% CI: 1.43-17.04; p = 0.012). Catheterization-related complications included hepatic artery dissection and splenic embolization. TAE controlled acute non-variceal upper GI bleeding effectively. TAE may be considered when endoscopic therapy is unavailable or unsuccessful. Correction of coagulopathy before TAE is recommended.

  9. A JOINT FRAMEWORK FOR 4D SEGMENTATION AND ESTIMATION OF SMOOTH TEMPORAL APPEARANCE CHANGES.

    PubMed

    Gao, Yang; Prastawa, Marcel; Styner, Martin; Piven, Joseph; Gerig, Guido

    2014-04-01

    Medical imaging studies increasingly use longitudinal images of individual subjects in order to follow-up changes due to development, degeneration, disease progression or efficacy of therapeutic intervention. Repeated image data of individuals are highly correlated, and the strong causality of information over time lead to the development of procedures for joint segmentation of the series of scans, called 4D segmentation. A main aim was improved consistency of quantitative analysis, most often solved via patient-specific atlases. Challenging open problems are contrast changes and occurance of subclasses within tissue as observed in multimodal MRI of infant development, neurodegeneration and disease. This paper proposes a new 4D segmentation framework that enforces continuous dynamic changes of tissue contrast patterns over time as observed in such data. Moreover, our model includes the capability to segment different contrast patterns within a specific tissue class, for example as seen in myelinated and unmyelinated white matter regions in early brain development. Proof of concept is shown with validation on synthetic image data and with 4D segmentation of longitudinal, multimodal pediatric MRI taken at 6, 12 and 24 months of age, but the methodology is generic w.r.t. different application domains using serial imaging.

  10. Quantitative Validation of the Presto Blue Metabolic Assay for Online Monitoring of Cell Proliferation in a 3D Perfusion Bioreactor System.

    PubMed

    Sonnaert, Maarten; Papantoniou, Ioannis; Luyten, Frank P; Schrooten, Jan Ir

    2015-06-01

    As the fields of tissue engineering and regenerative medicine mature toward clinical applications, the need for online monitoring both for quantitative and qualitative use becomes essential. Resazurin-based metabolic assays are frequently applied for determining cytotoxicity and have shown great potential for monitoring 3D bioreactor-facilitated cell culture. However, no quantitative correlation between the metabolic conversion rate of resazurin and cell number has been defined yet. In this work, we determined conversion rates of Presto Blue, a resazurin-based metabolic assay, for human periosteal cells during 2D and 3D static and 3D perfusion cultures. Our results showed that for the evaluated culture systems there is a quantitative correlation between the Presto Blue conversion rate and the cell number during the expansion phase with no influence of the perfusion-related parameters, that is, flow rate and shear stress. The correlation between the cell number and Presto Blue conversion subsequently enabled the definition of operating windows for optimal signal readouts. In conclusion, our data showed that the conversion of the resazurin-based Presto Blue metabolic assay can be used as a quantitative readout for online monitoring of cell proliferation in a 3D perfusion bioreactor system, although a system-specific validation is required.

  11. Quantitative Validation of the Presto Blue™ Metabolic Assay for Online Monitoring of Cell Proliferation in a 3D Perfusion Bioreactor System

    PubMed Central

    Sonnaert, Maarten; Papantoniou, Ioannis; Luyten, Frank P.

    2015-01-01

    As the fields of tissue engineering and regenerative medicine mature toward clinical applications, the need for online monitoring both for quantitative and qualitative use becomes essential. Resazurin-based metabolic assays are frequently applied for determining cytotoxicity and have shown great potential for monitoring 3D bioreactor-facilitated cell culture. However, no quantitative correlation between the metabolic conversion rate of resazurin and cell number has been defined yet. In this work, we determined conversion rates of Presto Blue™, a resazurin-based metabolic assay, for human periosteal cells during 2D and 3D static and 3D perfusion cultures. Our results showed that for the evaluated culture systems there is a quantitative correlation between the Presto Blue conversion rate and the cell number during the expansion phase with no influence of the perfusion-related parameters, that is, flow rate and shear stress. The correlation between the cell number and Presto Blue conversion subsequently enabled the definition of operating windows for optimal signal readouts. In conclusion, our data showed that the conversion of the resazurin-based Presto Blue metabolic assay can be used as a quantitative readout for online monitoring of cell proliferation in a 3D perfusion bioreactor system, although a system-specific validation is required. PMID:25336207

  12. Digit ratio (2D:4D) and hand preference for writing in the BBC Internet Study.

    PubMed

    Manning, J T; Peters, M

    2009-09-01

    The ratio of the length of the second to the fourth digit (2D:4D) may be negatively correlated with prenatal testosterone. Hand preference has been linked with prenatal testosterone and 2D:4D. Here we show that 2D:4D is associated with hand preference for writing in a large internet sample (n>170,000) in which participants self-reported their finger lengths. We replicated a significant association between right 2D:4D and writing hand preference (low right 2D:4D associated with left hand preference) as well as a significant correlation between writing hand preference and the difference between left and right 2D:4D or Dr-l (low Dr-l associated with left hand preference). A new significant correlation between left 2D:4D and writing hand preference was also shown (high left 2D:4D associated with left hand preference). There was a clear interaction between writing hand preference and 2D:4D: The left 2D:4D was significantly larger than the right 2D:4D in male and female left-handed writers, and the right hand 2D:4D was significantly larger than the left hand 2D:4D in male and female right-handed writers.

  13. Transcatheter valve implantation can alter fluid flow fields in aortic sinuses and ascending aorta

    NASA Astrophysics Data System (ADS)

    Saikrishnan, Neelakantan; Yoganathan, Ajit

    2012-11-01

    Transcatheter aortic valves (TAVs) are valve replacements used to treat aortic stenosis. Currently, these have been used in elderly patients at high-risk for open-heart procedures. Since these devices are implanted under fluoroscopic guidance, the implantation position of the valve can vary with respect to the native aortic valve annulus. The current study characterizes the altered hemodynamics in the aortic sinus and ascending aorta under different implantation (high and low) and cardiac output (2.5 and 5.0 L/min) conditions. Two commonly used TAV designs are studied using 2-D Particle Image Velocimetry (PIV). 200 phase locked images are obtained at every 25ms in the cardiac cycle, and the resulting vector fields are ensemble averaged. High implantation of the TAV with respect to the annulus causes weaker sinus washout and weaker sinus vortex formation. Additionally, the longer TAV leaflets can also result in a weaker sinus vortex. The level of turbulent fluctuations in the ascending aorta did not appear to be affected by axial positioning of the valve, but varied with cardiac output. The results of this study indicates that TAV positioning is important to be considered clinically, since this can affect coronary perfusion and potential flow stagnation near the valve.

  14. Quantitative analysis and feature recognition in 3-D microstructural data sets

    NASA Astrophysics Data System (ADS)

    Lewis, A. C.; Suh, C.; Stukowski, M.; Geltmacher, A. B.; Spanos, G.; Rajan, K.

    2006-12-01

    A three-dimensional (3-D) reconstruction of an austenitic stainless-steel microstructure was used as input for an image-based finite-element model to simulate the anisotropic elastic mechanical response of the microstructure. The quantitative data-mining and data-warehousing techniques used to correlate regions of high stress with critical microstructural features are discussed. Initial analysis of elastic stresses near grain boundaries due to mechanical loading revealed low overall correlation with their location in the microstructure. However, the use of data-mining and feature-tracking techniques to identify high-stress outliers revealed that many of these high-stress points are generated near grain boundaries and grain edges (triple junctions). These techniques also allowed for the differentiation between high stresses due to boundary conditions of the finite volume reconstructed, and those due to 3-D microstructural features.

  15. The d4 gene family in the human genome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chestkov, A.V.; Baka, I.D.; Kost, M.V.

    1996-08-15

    The d4 domain, a novel zinc finger-like structural motif, was first revealed in the rat neuro-d4 protein. Here we demonstrate that the d4 domain is conserved in evolution and that three related genes form a d4 family in the human genome. The human neuro-d4 is very similar to rat neuro-d4 at both the amino acid and the nucleotide levels. Moreover, the same splice variants have been detected among rat and human neuro-d4 transcripts. This gene has been localized on chromosome 19, and two other genes, members of the d4 family isolated by screening of the human genomic library at lowmore » stringency, have been mapped to chromosomes 11 and 14. The gene on chromosome 11 is the homolog of the ubiquitously expressed mouse gene ubi-d4/requiem, which is required for cell death after deprivation of trophic factors. A gene with a conserved d4 domain has been found in the genome of the nematode Caenorhabditis elegans. The conservation of d4 proteins from nematodes to vertebrates suggests that they have a general importance, but a diversity of d4 proteins expressed in vertebrate nervous systems suggests that some family members have special functions. 11 refs., 2 figs.« less

  16. Optimization of homonuclear 2D NMR for fast quantitative analysis: application to tropine-nortropine mixtures.

    PubMed

    Giraudeau, Patrick; Guignard, Nadia; Hillion, Emilie; Baguet, Evelyne; Akoka, Serge

    2007-03-12

    Quantitative analysis by (1)H NMR is often hampered by heavily overlapping signals that may occur for complex mixtures, especially those containing similar compounds. Bidimensional homonuclear NMR spectroscopy can overcome this difficulty. A thorough review of acquisition and post-processing parameters was carried out to obtain accurate and precise, quantitative 2D J-resolved and DQF-COSY spectra in a much reduced time, thus limiting the spectrometer instabilities in the course of time. The number of t(1) increments was reduced as much as possible, and standard deviation was improved by optimization of spectral width, number of transients, phase cycling and apodization function. Localized polynomial baseline corrections were applied to the relevant chemical shift areas. Our method was applied to tropine-nortropine mixtures. Quantitative J-resolved spectra were obtained in less than 3 min and quantitative DQF-COSY spectra in 12 min, with an accuracy of 3% for J-spectroscopy and 2% for DQF-COSY, and a standard deviation smaller than 1%.

  17. Motion-aware stroke volume quantification in 4D PC-MRI data of the human aorta.

    PubMed

    Köhler, Benjamin; Preim, Uta; Grothoff, Matthias; Gutberlet, Matthias; Fischbach, Katharina; Preim, Bernhard

    2016-02-01

    4D PC-MRI enables the noninvasive measurement of time-resolved, three-dimensional blood flow data that allow quantification of the hemodynamics. Stroke volumes are essential to assess the cardiac function and evolution of different cardiovascular diseases. The calculation depends on the wall position and vessel orientation, which both change during the cardiac cycle due to the heart muscle contraction and the pumped blood. However, current systems for the quantitative 4D PC-MRI data analysis neglect the dynamic character and instead employ a static 3D vessel approximation. We quantify differences between stroke volumes in the aorta obtained with and without consideration of its dynamics. We describe a method that uses the approximating 3D segmentation to automatically initialize segmentation algorithms that require regions inside and outside the vessel for each temporal position. This enables the use of graph cuts to obtain 4D segmentations, extract vessel surfaces including centerlines for each temporal position and derive motion information. The stroke volume quantification is compared using measuring planes in static (3D) vessels, planes with fixed angulation inside dynamic vessels (this corresponds to the common 2D PC-MRI) and moving planes inside dynamic vessels. Seven datasets with different pathologies such as aneurysms and coarctations were evaluated in close collaboration with radiologists. Compared to the experts' manual stroke volume estimations, motion-aware quantification performs, on average, 1.57% better than calculations without motion consideration. The mean difference between stroke volumes obtained with the different methods is 7.82%. Automatically obtained 4D segmentations overlap by 85.75% with manually generated ones. Incorporating motion information in the stroke volume quantification yields slight but not statistically significant improvements. The presented method is feasible for the clinical routine, since computation times are low and

  18. Impact of wait times on the effectiveness of transcatheter aortic valve replacement in severe aortic valve disease: a discrete event simulation model.

    PubMed

    Wijeysundera, Harindra C; Wong, William W L; Bennell, Maria C; Fremes, Stephen E; Radhakrishnan, Sam; Peterson, Mark; Ko, Dennis T

    2014-10-01

    There is increasing demand for transcatheter aortic valve replacement (TAVR) as the primary treatment option for patients with severe aortic stenosis who are high-risk surgical candidates or inoperable. We used mathematical simulation models to estimate the hypothetical effectiveness of TAVR with increasing wait times. We applied discrete event modelling, using data from the Placement of Aortic Transcatheter Valves (PARTNER) trials. We compared TAVR with medical therapy in the inoperable cohort, and compared TAVR to conventional aortic valve surgery in the high-risk cohort. One-year mortality and wait-time deaths were calculated in different scenarios by varying TAVR wait times from 10 days to 180 days, while maintaining a constant wait time for surgery at a mean of 15.6 days. In the inoperable cohort, the 1-year mortality for medical therapy was 50%. When the TAVR wait time was 10 days, the TAVR wait-time mortality was 1.9% with a 1-year mortality of 31.5%. TAVR wait-time deaths increased to 28.9% with a 180-day wait, with a 1-year mortality of 41.4%. In the high-risk cohort, the wait-time deaths and 1-year mortality for the surgical patients were 2.5% and 27%, respectively. The TAVR wait-time deaths increased from 2.2% with a 10-day wait to 22.4% with a 180-day wait, and a corresponding increase in 1-year mortality from 24.5% to 32.6%. Mortality with TAVR exceeded surgery when TAVR wait times exceeded 60 days. Modest increases in TAVR wait times have a substantial effect on the effectiveness of TAVR in inoperable patients and high-risk surgical candidates. Copyright © 2014 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  19. Transcatheter aortic valve replacement in patients with severe mitral or tricuspid regurgitation at extreme risk for surgery.

    PubMed

    Little, Stephen H; Popma, Jeffrey J; Kleiman, Neal S; Deeb, G Michael; Gleason, Thomas G; Yakubov, Steven J; Checuti, Stan; O'Hair, Daniel; Bajwa, Tanvir; Mumtaz, Mubashir; Maini, Brijeshwar; Hartman, Alan; Katz, Stanley; Robinson, Newell; Petrossian, George; Heiser, John; Merhi, William; Moore, B Jane; Li, Shuzhen; Adams, David H; Reardon, Michael J

    2018-05-01

    Patients with symptomatic severe aortic stenosis and severe mitral regurgitation or severe tricuspid regurgitation were excluded from the major transcatheter aortic valve replacement trials. We studied these 2 subgroups in patients at extreme risk for surgery in the prospective, nonrandomized, single-arm CoreValve US Expanded Use Study. The primary end point was all-cause mortality or major stroke at 1 year. A favorable medical benefit was defined as a Kansas City Cardiomyopathy Questionnaire overall summary score greater than 45 at 6 months and greater than 60 at 1 year and with a less than 10-point decrease from baseline. There were 53 patients in each group. Baseline characteristics for the severe mitral regurgitation and severe tricuspid regurgitation cohorts were age 84.2 ± 6.4 years and 84.9 ± 6.5 years; male, 29 (54.7%) and 22 (41.5%), and mean Society of Thoracic Surgeons score 9.9% ± 5.0% and 9.2% ± 4.0%, respectively. Improvement in valve regurgitation from baseline to 1 year occurred in 72.7% of the patients with severe mitral regurgitation and in 61.8% of patients with severe tricuspid regurgitation. A favorable medical benefit occurred in 31 of 47 patients (66.0%) with severe mitral regurgitation and 33 of 47 patients (70.2%) with severe tricuspid regurgitation at 6 months, and in 25 of 44 patients (56.8%) with severe mitral regurgitation and 24 of 45 patients (53.3%) with severe tricuspid regurgitation at 1 year. All-cause mortality or major stroke for the severe mitral regurgitation and severe tricuspid regurgitation cohorts were 11.3% and 3.8% at 30 days and 21.0% and 19.2% at 1 year, respectively. There were no major strokes in either group at 1 year. Transcatheter aortic valve replacement in patients with severe mitral regurgitation or severe tricuspid regurgitation is reasonable and safe and leads to improvement in atrioventricular valve regurgitation. Copyright © 2018 The American Association for Thoracic Surgery

  20. Simultaneous occurrence of a severe Morel-Lavallée lesion and gluteal muscle necrosis as a sequela of transcatheter angiographic embolization following pelvic fracture: a case report.

    PubMed

    Shimizu, Takayoshi; Matsuda, Shuichi; Sakuragi, Atsushi; Tsukie, Tomio; Kawanabe, Keiichi

    2015-03-26

    Morel-Lavallée lesions are posttraumatic hemolymphatic collections caused by disruption of the interfascial planes between the subcutaneous soft tissue and muscle. Severe peripelvic Morel-Lavallée lesions have rarely been reported in the literature. By contrast, a number of cases of gluteal muscle necrosis following transcatheter angiographic embolization for pelvic fracture have been reported. Each entity can result in severe infection and sepsis, and the mortality rate in such cases is quite high. However, to date, no previous reports have described a case in which these life-threatening entities occurred simultaneously. A 32-year-old Asian man simultaneously developed severe peripelvic Morel-Lavallée lesions and gluteal muscle necrosis with sepsis following transcatheter angiographic embolization after an unstable pelvic fracture. Extremely large skin and soft tissue defects, which were untreatable with any commonly used flaps, were generated after repeated debridement. In addition, a deep-bone infection was suspected in his left fractured iliac bone, while motor function was almost completely lost in his left leg, possibly as a sequela of transcatheter angiographic embolization. As a result of his condition, a left hemipelvectomy was unavoidable. A pedicled fillet flap from his sacrificed left limb was used for the treatment of the defects and to provide a durable base for a prosthesis. Our patient survived and returned to his previous job 24 months after the surgery wearing a prosthetic left leg. As illustrated by the present case, severe peripelvic Morel-Lavallée lesions and gluteal muscle necrosis following transcatheter angiographic embolization can occur simultaneously after unstable pelvic fractures. Physicians should recognize that these entities can result in life-threatening sepsis and, therefore, should attempt to detect them as early as possible. When hemipelvectomy is unavoidable, a pedicled upper and lower leg in-continuity fillet flap may