Sample records for quantitative analytical method

  1. The current preference for the immuno-analytical ELISA method for quantitation of steroid hormones (endocrine disruptor compounds) in wastewater in South Africa.

    PubMed

    Manickum, Thavrin; John, Wilson

    2015-07-01

    The availability of national test centers to offer a routine service for analysis and quantitation of some selected steroid hormones [natural estrogens (17-β-estradiol, E2; estrone, E1; estriol, E3), synthetic estrogen (17-α-ethinylestradiol, EE2), androgen (testosterone), and progestogen (progesterone)] in wastewater matrix was investigated; corresponding internationally used chemical- and immuno-analytical test methods were reviewed. The enzyme-linked immunosorbent assay (ELISA) (immuno-analytical technique) was also assessed for its suitability as a routine test method to quantitate the levels of these hormones at a sewage/wastewater treatment plant (WTP) (Darvill, Pietermaritzburg, South Africa), over a 2-year period. The method performance and other relevant characteristics of the immuno-analytical ELISA method were compared to the conventional chemical-analytical methodology, like gas/liquid chromatography-mass spectrometry (GC/LC-MS), and GC-LC/tandem mass spectrometry (MSMS), for quantitation of the steroid hormones in wastewater and environmental waters. The national immuno-analytical ELISA technique was found to be sensitive (LOQ 5 ng/L, LOD 0.2-5 ng/L), accurate (mean recovery 96%), precise (RSD 7-10%), and cost-effective for screening and quantitation of these steroid hormones in wastewater and environmental water matrix. A survey of the most current international literature indicates a fairly equal use of the LC-MS/MS, GC-MS/MS (chemical-analytical), and ELISA (immuno-analytical) test methods for screening and quantitation of the target steroid hormones in both water and wastewater matrix. Internationally, the observed sensitivity, based on LOQ (ng/L), for the steroid estrogens E1, E2, EE2, is, in decreasing order: LC-MSMS (0.08-9.54) > GC-MS (1) > ELISA (5) (chemical-analytical > immuno-analytical). At the national level, the routine, unoptimized chemical-analytical LC-MSMS method was found to lack the required sensitivity for meeting environmental requirements for steroid hormone quantitation. Further optimization of the sensitivity of the chemical-analytical LC-tandem mass spectrometry methods, especially for wastewater screening, in South Africa is required. Risk assessment studies showed that it was not practical to propose standards or allowable limits for the steroid estrogens E1, E2, EE2, and E3; the use of predicted-no-effect concentration values of the steroid estrogens appears to be appropriate for use in their risk assessment in relation to aquatic organisms. For raw water sources, drinking water, raw and treated wastewater, the use of bioassays, with trigger values, is a useful screening tool option to decide whether further examination of specific endocrine activity may be warranted, or whether concentrations of such activity are of low priority, with respect to health concerns in the human population. The achievement of improved quantitation limits for immuno-analytical methods, like ELISA, used for compound quantitation, and standardization of the method for measuring E2 equivalents (EEQs) used for biological activity (endocrine: e.g., estrogenic) are some areas for future EDC research.

  2. 10 CFR Appendix A to Subpart C of... - Procedures, Interpretations and Policies for Consideration of New or Revised Energy Conservation...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... robust analytical methods. The Department seeks to use qualitative and quantitative analytical methods... uncertainties will be carried forward in subsequent analyses. The use of quantitative models will be... manufacturers and other interested parties. The use of quantitative models will be supplemented by qualitative...

  3. 10 CFR Appendix A to Subpart C of... - Procedures, Interpretations and Policies for Consideration of New or Revised Energy Conservation...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... robust analytical methods. The Department seeks to use qualitative and quantitative analytical methods... uncertainties will be carried forward in subsequent analyses. The use of quantitative models will be... manufacturers and other interested parties. The use of quantitative models will be supplemented by qualitative...

  4. 10 CFR Appendix A to Subpart C of... - Procedures, Interpretations and Policies for Consideration of New or Revised Energy Conservation...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... robust analytical methods. The Department seeks to use qualitative and quantitative analytical methods... uncertainties will be carried forward in subsequent analyses. The use of quantitative models will be... manufacturers and other interested parties. The use of quantitative models will be supplemented by qualitative...

  5. Major advances in testing of dairy products: milk component and dairy product attribute testing.

    PubMed

    Barbano, D M; Lynch, J M

    2006-04-01

    Milk component analysis is relatively unusual in the field of quantitative analytical chemistry because an analytical test result determines the allocation of very large amounts of money between buyers and sellers of milk. Therefore, there is high incentive to develop and refine these methods to achieve a level of analytical performance rarely demanded of most methods or laboratory staff working in analytical chemistry. In the last 25 yr, well-defined statistical methods to characterize and validate analytical method performance combined with significant improvements in both the chemical and instrumental methods have allowed achievement of improved analytical performance for payment testing. A shift from marketing commodity dairy products to the development, manufacture, and marketing of value added dairy foods for specific market segments has created a need for instrumental and sensory approaches and quantitative data to support product development and marketing. Bringing together sensory data from quantitative descriptive analysis and analytical data from gas chromatography olfactometry for identification of odor-active compounds in complex natural dairy foods has enabled the sensory scientist and analytical chemist to work together to improve the consistency and quality of dairy food flavors.

  6. Surrogate matrix and surrogate analyte approaches for definitive quantitation of endogenous biomolecules.

    PubMed

    Jones, Barry R; Schultz, Gary A; Eckstein, James A; Ackermann, Bradley L

    2012-10-01

    Quantitation of biomarkers by LC-MS/MS is complicated by the presence of endogenous analytes. This challenge is most commonly overcome by calibration using an authentic standard spiked into a surrogate matrix devoid of the target analyte. A second approach involves use of a stable-isotope-labeled standard as a surrogate analyte to allow calibration in the actual biological matrix. For both methods, parallelism between calibration standards and the target analyte in biological matrix must be demonstrated in order to ensure accurate quantitation. In this communication, the surrogate matrix and surrogate analyte approaches are compared for the analysis of five amino acids in human plasma: alanine, valine, methionine, leucine and isoleucine. In addition, methodology based on standard addition is introduced, which enables a robust examination of parallelism in both surrogate analyte and surrogate matrix methods prior to formal validation. Results from additional assays are presented to introduce the standard-addition methodology and to highlight the strengths and weaknesses of each approach. For the analysis of amino acids in human plasma, comparable precision and accuracy were obtained by the surrogate matrix and surrogate analyte methods. Both assays were well within tolerances prescribed by regulatory guidance for validation of xenobiotic assays. When stable-isotope-labeled standards are readily available, the surrogate analyte approach allows for facile method development. By comparison, the surrogate matrix method requires greater up-front method development; however, this deficit is offset by the long-term advantage of simplified sample analysis.

  7. Analytical method for the accurate determination of tricothecenes in grains using LC-MS/MS: a comparison between MRM transition and MS3 quantitation.

    PubMed

    Lim, Chee Wei; Tai, Siew Hoon; Lee, Lin Min; Chan, Sheot Harn

    2012-07-01

    The current food crisis demands unambiguous determination of mycotoxin contamination in staple foods to achieve safer food for consumption. This paper describes the first accurate LC-MS/MS method developed to analyze tricothecenes in grains by applying multiple reaction monitoring (MRM) transition and MS(3) quantitation strategies in tandem. The tricothecenes are nivalenol, deoxynivalenol, deoxynivalenol-3-glucoside, fusarenon X, 3-acetyl-deoxynivalenol, 15-acetyldeoxynivalenol, diacetoxyscirpenol, and HT-2 and T-2 toxins. Acetic acid and ammonium acetate were used to convert the analytes into their respective acetate adducts and ammonium adducts under negative and positive MS polarity conditions, respectively. The mycotoxins were separated by reversed-phase LC in a 13.5-min run, ionized using electrospray ionization, and detected by tandem mass spectrometry. Analyte-specific mass-to-charge (m/z) ratios were used to perform quantitation under MRM transition and MS(3) (linear ion trap) modes. Three experiments were made for each quantitation mode and matrix in batches over 6 days for recovery studies. The matrix effect was investigated at concentration levels of 20, 40, 80, 120, 160, and 200 μg kg(-1) (n = 3) in 5 g corn flour and rice flour. Extraction with acetonitrile provided a good overall recovery range of 90-108% (n = 3) at three levels of spiking concentration of 40, 80, and 120 μg kg(-1). A quantitation limit of 2-6 μg kg(-1) was achieved by applying an MRM transition quantitation strategy. Under MS(3) mode, a quantitation limit of 4-10 μg kg(-1) was achieved. Relative standard deviations of 2-10% and 2-11% were reported for MRM transition and MS(3) quantitation, respectively. The successful utilization of MS(3) enabled accurate analyte fragmentation pattern matching and its quantitation, leading to the development of analytical methods in fields that demand both analyte specificity and fragmentation fingerprint-matching capabilities that are unavailable under MRM transition.

  8. Simplex and duplex event-specific analytical methods for functional biotech maize.

    PubMed

    Lee, Seong-Hun; Kim, Su-Jeong; Yi, Bu-Young

    2009-08-26

    Analytical methods are very important in the control of genetically modified organism (GMO) labeling systems or living modified organism (LMO) management for biotech crops. Event-specific primers and probes were developed for qualitative and quantitative analysis for biotech maize event 3272 and LY 038 on the basis of the 3' flanking regions, respectively. The qualitative primers confirmed the specificity by a single PCR product and sensitivity to 0.05% as a limit of detection (LOD). Simplex and duplex quantitative methods were also developed using TaqMan real-time PCR. One synthetic plasmid was constructed from two taxon-specific DNA sequences of maize and two event-specific 3' flanking DNA sequences of event 3272 and LY 038 as reference molecules. In-house validation of the quantitative methods was performed using six levels of mixing samples, from 0.1 to 10.0%. As a result, the biases from the true value and the relative deviations were all within the range of +/-30%. Limits of quantitation (LOQs) of the quantitative methods were all 0.1% for simplex real-time PCRs of event 3272 and LY 038 and 0.5% for duplex real-time PCR of LY 038. This study reports that event-specific analytical methods were applicable for qualitative and quantitative analysis for biotech maize event 3272 and LY 038.

  9. Quantification of HCV RNA in Liver Tissue by bDNA Assay.

    PubMed

    Dailey, P J; Collins, M L; Urdea, M S; Wilber, J C

    1999-01-01

    With this statement, Sherlock and Dooley have described two of the three major challenges involved in quantitatively measuring any analyte in tissue samples: the distribution of the analyte in the tissue; and the standard of reference, or denominator, with which to make comparisons between tissue samples. The third challenge for quantitative measurement of an analyte in tissue is to ensure reproducible and quantitative recovery of the analyte on extraction from tissue samples. This chapter describes a method that can be used to measure HCV RNA quantitatively in liver biopsy and tissue samples using the bDNA assay. All three of these challenges-distribution, denominator, and recovery-apply to the measurement of HCV RNA in liver biopsies.

  10. Analytical methods for quantitation of prenylated flavonoids from hops.

    PubMed

    Nikolić, Dejan; van Breemen, Richard B

    2013-01-01

    The female flowers of hops ( Humulus lupulus L.) are used as a flavoring agent in the brewing industry. There is growing interest in possible health benefits of hops, particularly as estrogenic and chemopreventive agents. Among the possible active constituents, most of the attention has focused on prenylated flavonoids, which can chemically be classified as prenylated chalcones and prenylated flavanones. Among chalcones, xanthohumol (XN) and desmethylxanthohumol (DMX) have been the most studied, while among flavanones, 8-prenylnaringenin (8-PN) and 6-prenylnaringenin (6-PN) have received the most attention. Because of the interest in medicinal properties of prenylated flavonoids, there is demand for accurate, reproducible and sensitive analytical methods to quantify these compounds in various matrices. Such methods are needed, for example, for quality control and standardization of hop extracts, measurement of the content of prenylated flavonoids in beer, and to determine pharmacokinetic properties of prenylated flavonoids in animals and humans. This review summarizes currently available analytical methods for quantitative analysis of the major prenylated flavonoids, with an emphasis on the LC-MS and LC-MS-MS methods and their recent applications to biomedical research on hops. This review covers all methods in which prenylated flavonoids have been measured, either as the primary analytes or as a part of a larger group of analytes. The review also discusses methodological issues relating to the quantitative analysis of these compounds regardless of the chosen analytical approach.

  11. ELEGANT ENVIRONMENTAL IMMUNOASSAYS

    EPA Science Inventory

    Immunochemical methods are based on selective antibodies directed to a particular target analyte. The specific binding between antibody and analyte can be used for detection and quantitation. Methods such as the enzyme-linked immunosorbent assay (ELISA) can provide a sensitiv...

  12. Analytical analysis and implementation of a low-speed high-torque permanent magnet vernier in-wheel motor for electric vehicle

    NASA Astrophysics Data System (ADS)

    Li, Jiangui; Wang, Junhua; Zhigang, Zhao; Yan, Weili

    2012-04-01

    In this paper, analytical analysis of the permanent magnet vernier (PMV) is presented. The key is to analytically solve the governing Laplacian/quasi-Poissonian field equations in the motor regions. By using the time-stepping finite element method, the analytical method is verified. Hence, the performances of the PMV machine are quantitatively compared with that of the analytical results. The analytical results agree well with the finite element method results. Finally, the experimental results are given to further show the validity of the analysis.

  13. Application of the correlation constrained multivariate curve resolution alternating least-squares method for analyte quantitation in the presence of unexpected interferences using first-order instrumental data.

    PubMed

    Goicoechea, Héctor C; Olivieri, Alejandro C; Tauler, Romà

    2010-03-01

    Correlation constrained multivariate curve resolution-alternating least-squares is shown to be a feasible method for processing first-order instrumental data and achieve analyte quantitation in the presence of unexpected interferences. Both for simulated and experimental data sets, the proposed method could correctly retrieve the analyte and interference spectral profiles and perform accurate estimations of analyte concentrations in test samples. Since no information concerning the interferences was present in calibration samples, the proposed multivariate calibration approach including the correlation constraint facilitates the achievement of the so-called second-order advantage for the analyte of interest, which is known to be present for more complex higher-order richer instrumental data. The proposed method is tested using a simulated data set and two experimental data systems, one for the determination of ascorbic acid in powder juices using UV-visible absorption spectral data, and another for the determination of tetracycline in serum samples using fluorescence emission spectroscopy.

  14. Identification and confirmation of chemical residues by chromatography-mass spectrometry and other techniques

    USDA-ARS?s Scientific Manuscript database

    A quantitative answer cannot exist in an analysis without a qualitative component to give enough confidence that the result meets the analytical needs for the analysis (i.e. the result relates to the analyte and not something else). Just as a quantitative method must typically undergo an empirical ...

  15. A Model of Risk Analysis in Analytical Methodology for Biopharmaceutical Quality Control.

    PubMed

    Andrade, Cleyton Lage; Herrera, Miguel Angel De La O; Lemes, Elezer Monte Blanco

    2018-01-01

    One key quality control parameter for biopharmaceutical products is the analysis of residual cellular DNA. To determine small amounts of DNA (around 100 pg) that may be in a biologically derived drug substance, an analytical method should be sensitive, robust, reliable, and accurate. In principle, three techniques have the ability to measure residual cellular DNA: radioactive dot-blot, a type of hybridization; threshold analysis; and quantitative polymerase chain reaction. Quality risk management is a systematic process for evaluating, controlling, and reporting of risks that may affects method capabilities and supports a scientific and practical approach to decision making. This paper evaluates, by quality risk management, an alternative approach to assessing the performance risks associated with quality control methods used with biopharmaceuticals, using the tool hazard analysis and critical control points. This tool provides the possibility to find the steps in an analytical procedure with higher impact on method performance. By applying these principles to DNA analysis methods, we conclude that the radioactive dot-blot assay has the largest number of critical control points, followed by quantitative polymerase chain reaction, and threshold analysis. From the analysis of hazards (i.e., points of method failure) and the associated method procedure critical control points, we conclude that the analytical methodology with the lowest risk for performance failure for residual cellular DNA testing is quantitative polymerase chain reaction. LAY ABSTRACT: In order to mitigate the risk of adverse events by residual cellular DNA that is not completely cleared from downstream production processes, regulatory agencies have required the industry to guarantee a very low level of DNA in biologically derived pharmaceutical products. The technique historically used was radioactive blot hybridization. However, the technique is a challenging method to implement in a quality control laboratory: It is laborious, time consuming, semi-quantitative, and requires a radioisotope. Along with dot-blot hybridization, two alternatives techniques were evaluated: threshold analysis and quantitative polymerase chain reaction. Quality risk management tools were applied to compare the techniques, taking into account the uncertainties, the possibility of circumstances or future events, and their effects upon method performance. By illustrating the application of these tools with DNA methods, we provide an example of how they can be used to support a scientific and practical approach to decision making and can assess and manage method performance risk using such tools. This paper discusses, considering the principles of quality risk management, an additional approach to the development and selection of analytical quality control methods using the risk analysis tool hazard analysis and critical control points. This tool provides the possibility to find the method procedural steps with higher impact on method reliability (called critical control points). Our model concluded that the radioactive dot-blot assay has the larger number of critical control points, followed by quantitative polymerase chain reaction and threshold analysis. Quantitative polymerase chain reaction is shown to be the better alternative analytical methodology in residual cellular DNA analysis. © PDA, Inc. 2018.

  16. Vitamin K

    USDA-ARS?s Scientific Manuscript database

    A wide range of analytical techniques are available for the detection, quantitation, and evaluation of vitamin K in foods. The methods vary from simple to complex depending on extraction, separation, identification and detection of the analyte. Among the extraction methods applied for vitamin K anal...

  17. Ratio of sequential chromatograms for quantitative analysis and peak deconvolution: Application to standard addition method and process monitoring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Synovec, R.E.; Johnson, E.L.; Bahowick, T.J.

    1990-08-01

    This paper describes a new technique for data analysis in chromatography, based on taking the point-by-point ratio of sequential chromatograms that have been base line corrected. This ratio chromatogram provides a robust means for the identification and the quantitation of analytes. In addition, the appearance of an interferent is made highly visible, even when it coelutes with desired analytes. For quantitative analysis, the region of the ratio chromatogram corresponding to the pure elution of an analyte is identified and is used to calculate a ratio value equal to the ratio of concentrations of the analyte in sequential injections. For themore » ratio value calculation, a variance-weighted average is used, which compensates for the varying signal-to-noise ratio. This ratio value, or equivalently the percent change in concentration, is the basis of a chromatographic standard addition method and an algorithm to monitor analyte concentration in a process stream. In the case of overlapped peaks, a spiking procedure is used to calculate both the original concentration of an analyte and its signal contribution to the original chromatogram. Thus, quantitation and curve resolution may be performed simultaneously, without peak modeling or curve fitting. These concepts are demonstrated by using data from ion chromatography, but the technique should be applicable to all chromatographic techniques.« less

  18. Simultaneous quantitative analysis of main components in linderae reflexae radix with one single marker.

    PubMed

    Wang, Li-Li; Zhang, Yun-Bin; Sun, Xiao-Ya; Chen, Sui-Qing

    2016-05-08

    Establish a quantitative analysis of multi-components by the single marker (QAMS) method for quality evaluation and validate its feasibilities by the simultaneous quantitative assay of four main components in Linderae Reflexae Radix. Four main components of pinostrobin, pinosylvin, pinocembrin, and 3,5-dihydroxy-2-(1- p -mentheneyl)- trans -stilbene were selected as analytes to evaluate the quality by RP-HPLC coupled with a UV-detector. The method was evaluated by a comparison of the quantitative results between the external standard method and QAMS with a different HPLC system. The results showed that no significant differences were found in the quantitative results of the four contents of Linderae Reflexae Radix determined by the external standard method and QAMS (RSD <3%). The contents of four analytes (pinosylvin, pinocembrin, pinostrobin, and Reflexanbene I) in Linderae Reflexae Radix were determined by the single marker of pinosylvin. This fingerprint was the spectra determined by Shimadzu LC-20AT and Waters e2695 HPLC that were equipped with three different columns.

  19. Analytical capabilities and services of Lawrence Livermore Laboratory's General Chemistry Division. [Methods available at Lawrence Livermore

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gutmacher, R.; Crawford, R.

    This comprehensive guide to the analytical capabilities of Lawrence Livermore Laboratory's General Chemistry Division describes each analytical method in terms of its principle, field of application, and qualitative and quantitative uses. Also described are the state and quantity of sample required for analysis, processing time, available instrumentation, and responsible personnel.

  20. Analytical aspects of hydrogen exchange mass spectrometry

    PubMed Central

    Engen, John R.; Wales, Thomas E.

    2016-01-01

    The analytical aspects of measuring hydrogen exchange by mass spectrometry are reviewed. The nature of analytical selectivity in hydrogen exchange is described followed by review of the analytical tools required to accomplish fragmentation, separation, and the mass spectrometry measurements under restrictive exchange quench conditions. In contrast to analytical quantitation that relies on measurements of peak intensity or area, quantitation in hydrogen exchange mass spectrometry depends on measuring a mass change with respect to an undeuterated or deuterated control, resulting in a value between zero and the maximum amount of deuterium that could be incorporated. Reliable quantitation is a function of experimental fidelity and to achieve high measurement reproducibility, a large number of experimental variables must be controlled during sample preparation and analysis. The method also reports on important qualitative aspects of the sample, including conformational heterogeneity and population dynamics. PMID:26048552

  1. Quantitative phase imaging method based on an analytical nonparaxial partially coherent phase optical transfer function.

    PubMed

    Bao, Yijun; Gaylord, Thomas K

    2016-11-01

    Multifilter phase imaging with partially coherent light (MFPI-PC) is a promising new quantitative phase imaging method. However, the existing MFPI-PC method is based on the paraxial approximation. In the present work, an analytical nonparaxial partially coherent phase optical transfer function is derived. This enables the MFPI-PC to be extended to the realistic nonparaxial case. Simulations over a wide range of test phase objects as well as experimental measurements on a microlens array verify higher levels of imaging accuracy compared to the paraxial method. Unlike the paraxial version, the nonparaxial MFPI-PC with obliquity factor correction exhibits no systematic error. In addition, due to its analytical expression, the increase in computation time compared to the paraxial version is negligible.

  2. Simultaneous quantitation of hydroxychloroquine and its metabolites in mouse blood and tissues using LC-ESI-MS/MS: An application for pharmacokinetic studies.

    PubMed

    Chhonker, Yashpal S; Sleightholm, Richard L; Li, Jing; Oupický, David; Murry, Daryl J

    2018-01-01

    Hydroxychloroquine (HCQ) has been shown to disrupt autophagy and sensitize cancer cells to radiation and chemotherapeutic agents. However, the optimal delivery method, dose, and tumor concentrations required for these effects are not known. This is in part due to a lack of sensitive and reproducible analytical methods for HCQ quantitation in small animals. As such, we developed and validated a selective and sensitive liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) method for simultaneous quantitation of hydroxychloroquine and its metabolites in mouse blood and tissues. The chromatographic separation and detection of analytes were achieved on a reversed phase Thermo Aquasil C 18 (50×4.6mm, 3μ) column, with gradient elution using 0.2% formic acid and 0.1% formic acid in methanol as mobile phase at a flow rate of 0.5mL/min. Simple protein precipitation was utilized for extraction of analytes from the desired matrix. Analytes were separated and quantitated using MS/MS with an electrospray ionization source in positive multiple reaction monitoring (MRM) mode. The MS/MS response was linear over the concentration range from 1 to 2000ng/mL for all analytes with a correlation coefficient (R 2 ) of 0.998 or better. The within- and between-day precision (relative standard deviation, % RSD) and accuracy were within the acceptable limits per FDA guidelines. The validated method was successfully applied to a preclinical pharmacokinetic mouse study involving low volume blood and tissue samples for hydroxychloroquine and metabolites. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Quantitative evaluation of analyte transport on microfluidic paper-based analytical devices (μPADs).

    PubMed

    Ota, Riki; Yamada, Kentaro; Suzuki, Koji; Citterio, Daniel

    2018-02-07

    The transport efficiency during capillary flow-driven sample transport on microfluidic paper-based analytical devices (μPADs) made from filter paper has been investigated for a selection of model analytes (Ni 2+ , Zn 2+ , Cu 2+ , PO 4 3- , bovine serum albumin, sulforhodamine B, amaranth) representing metal cations, complex anions, proteins and anionic molecules. For the first time, the transport of the analytical target compounds rather than the sample liquid, has been quantitatively evaluated by means of colorimetry and absorption spectrometry-based methods. The experiments have revealed that small paperfluidic channel dimensions, additional user operation steps (e.g. control of sample volume, sample dilution, washing step) as well as the introduction of sample liquid wicking areas allow to increase analyte transport efficiency. It is also shown that the interaction of analytes with the negatively charged cellulosic paper substrate surface is strongly influenced by the physico-chemical properties of the model analyte and can in some cases (Cu 2+ ) result in nearly complete analyte depletion during sample transport. The quantitative information gained through these experiments is expected to contribute to the development of more sensitive μPADs.

  4. Quantitative SIMS Imaging of Agar-Based Microbial Communities.

    PubMed

    Dunham, Sage J B; Ellis, Joseph F; Baig, Nameera F; Morales-Soto, Nydia; Cao, Tianyuan; Shrout, Joshua D; Bohn, Paul W; Sweedler, Jonathan V

    2018-05-01

    After several decades of widespread use for mapping elemental ions and small molecular fragments in surface science, secondary ion mass spectrometry (SIMS) has emerged as a powerful analytical tool for molecular imaging in biology. Biomolecular SIMS imaging has primarily been used as a qualitative technique; although the distribution of a single analyte can be accurately determined, it is difficult to map the absolute quantity of a compound or even to compare the relative abundance of one molecular species to that of another. We describe a method for quantitative SIMS imaging of small molecules in agar-based microbial communities. The microbes are cultivated on a thin film of agar, dried under nitrogen, and imaged directly with SIMS. By use of optical microscopy, we show that the area of the agar is reduced by 26 ± 2% (standard deviation) during dehydration, but the overall biofilm morphology and analyte distribution are largely retained. We detail a quantitative imaging methodology, in which the ion intensity of each analyte is (1) normalized to an external quadratic regression curve, (2) corrected for isomeric interference, and (3) filtered for sample-specific noise and lower and upper limits of quantitation. The end result is a two-dimensional surface density image for each analyte. The sample preparation and quantitation methods are validated by quantitatively imaging four alkyl-quinolone and alkyl-quinoline N-oxide signaling molecules (including Pseudomonas quinolone signal) in Pseudomonas aeruginosa colony biofilms. We show that the relative surface densities of the target biomolecules are substantially different from values inferred through direct intensity comparison and that the developed methodologies can be used to quantitatively compare as many ions as there are available standards.

  5. [The development and validation of the methods for the quantitative determination of sibutramine derivatives in dietary supplements].

    PubMed

    Stern, K I; Malkova, T L

    The objective of the present study was the development and validation of sibutramine demethylated derivatives, desmethyl sibutramine and didesmethyl sibutramine. Gas-liquid chromatography with the flame ionization detector was used for the quantitative determination of the above substances in dietary supplements. The conditions for the chromatographic determination of the analytes in the presence of the reference standard, methyl stearate, were proposed allowing to achieve the efficient separation. The method has the necessary sensitivity, specificity, linearity, accuracy, and precision (on the intra-day and inter-day basis) which suggests its good validation characteristics. The proposed method can be employed in the analytical laboratories for the quantitative determination of sibutramine derivatives in biologically active dietary supplements.

  6. Differential homogeneous immunosensor device

    DOEpatents

    Malmros, Mark K.; Gulbinski, III, Julian

    1990-04-10

    There is provided a novel method of testing for the presence of an analyte in a fluid suspected of containing the same. In this method, in the presence of the analyte, a substance capable of modifying certain characteristics of the substrate is bound to the substrate and the change in these qualities is measured. While the method may be modified for carrying out quantitative differential analyses, it eliminates the need for washing analyte from the substrate which is characteristic of prior art methods.

  7. HPLC method development for evolving applications in the pharmaceutical industry and nanoscale chemistry

    NASA Astrophysics Data System (ADS)

    Castiglione, Steven Louis

    As scientific research trends towards trace levels and smaller architectures, the analytical chemist is often faced with the challenge of quantitating said species in a variety of matricies. The challenge is heightened when the analytes prove to be potentially toxic or possess physical or chemical properties that make traditional analytical methods problematic. In such cases, the successful development of an acceptable quantitative method plays a critical role in the ability to further develop the species under study. This is particularly true for pharmaceutical impurities and nanoparticles (NP). The first portion of the research focuses on the development of a part-per-billion level HPLC method for a substituted phenazine-class pharmaceutical impurity. The development of this method was required due to the need for a rapid methodology to quantitatively determine levels of a potentially toxic phenazine moiety in order to ensure patient safety. As the synthetic pathway for the active ingredient was continuously refined to produce progressively lower amounts of the phenazine impurity, the approach for increasingly sensitive quantitative methods was required. The approaches evolved across four discrete methods, each employing a unique scheme for analyte detection. All developed methods were evaluated with regards to accuracy, precision and linear adherence as well as ancillary benefits and detriments -- e.g., one method in this evolution demonstrated the ability to resolve and detect other species from the phenazine class. The second portion of the research focuses on the development of an HPLC method for the quantitative determination of NP size distributions. The current methodology for the determination of NP sizes employs tunneling electron microscopy (TEM), which requires sample drying without particle size alteration and which, in many cases, may prove infeasible due to cost or availability. The feasibility of an HPLC method for NP size characterizations evolved across three methods, each employing a different approach for size resolution. These methods were evaluated primarily for sensitivity, which proved to be a substantial hurdle to further development, but does not appear to deter future research efforts.

  8. Examining a Paradigm Shift in Organic Depot-Level Software Maintenance for Army Communications and Electronics Equipment

    DTIC Science & Technology

    2015-05-30

    study used quantitative and qualitative analytical methods in the examination of software versus hardware maintenance trends and forecasts, human and...financial resources at TYAD and SEC, and overall compliance with Title 10 mandates (e.g., 10 USC 2466). Quantitative methods were executed by...Systems (PEO EIS). These methods will provide quantitative-based analysis on which to base and justify trends and gaps, as well as qualitative methods

  9. Sample normalization methods in quantitative metabolomics.

    PubMed

    Wu, Yiman; Li, Liang

    2016-01-22

    To reveal metabolomic changes caused by a biological event in quantitative metabolomics, it is critical to use an analytical tool that can perform accurate and precise quantification to examine the true concentration differences of individual metabolites found in different samples. A number of steps are involved in metabolomic analysis including pre-analytical work (e.g., sample collection and storage), analytical work (e.g., sample analysis) and data analysis (e.g., feature extraction and quantification). Each one of them can influence the quantitative results significantly and thus should be performed with great care. Among them, the total sample amount or concentration of metabolites can be significantly different from one sample to another. Thus, it is critical to reduce or eliminate the effect of total sample amount variation on quantification of individual metabolites. In this review, we describe the importance of sample normalization in the analytical workflow with a focus on mass spectrometry (MS)-based platforms, discuss a number of methods recently reported in the literature and comment on their applicability in real world metabolomics applications. Sample normalization has been sometimes ignored in metabolomics, partially due to the lack of a convenient means of performing sample normalization. We show that several methods are now available and sample normalization should be performed in quantitative metabolomics where the analyzed samples have significant variations in total sample amounts. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Differential homogeneous immunosensor device

    DOEpatents

    Malmros, M.K.; Gulbinski, J. III.

    1990-04-10

    There is provided a novel method of testing for the presence of an analyte in a fluid suspected of containing the same. In this method, in the presence of the analyte, a substance capable of modifying certain characteristics of the substrate is bound to the substrate and the change in these qualities is measured. While the method may be modified for carrying out quantitative differential analyses, it eliminates the need for washing the analyte from the substrate which is characteristic of prior art methods. 12 figs.

  11. Current issues involving screening and identification of chemical contaminants in foods by mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    Although quantitative analytical methods must be empirically validated prior to their actual use in a variety of applications, including regulatory monitoring of chemical adulterants in foods, validation of qualitative method performance for the analytes and matrices of interest is frequently ignore...

  12. [Rapid determination of 40 pesticide residues in fruits using gas chromatography-mass spectrometry coupled with analyte protectants to compensate for matrix effects].

    PubMed

    Xu, Xiuli; Zhao, Haixiang; Li, Li; Liu, Hanxia; Ren, Heling; Zhong, Weike

    2012-03-01

    A gas chromatography-mass spectrometry (GC-MS) method was developed for the determination of 40 pesticides in fruits. The effects of adding analyte protectants were evaluated for compensating matrix effects and the impacts on the quantitative results. A new combination of analyte protectants - Polyethylene Glycol 400 (PEG 400) and olive oil combination, which can be dissolved in acetone, was used for the quantitative analysis. The pesticides were extracted from fruit samples with acetonitrile and the extracts were cleaned up using micro-solid phase extraction. A GC-MS method in selective ion monitoring (SIM) mode coupled with large volume injection was finally developed. Using the newly developed analyte protectant combination of PEG 400 and olive oil, a good linearity was obtained in the range of 1 - 200 microg/L with coefficients better than 0.99, and the detection limits were between 0.1 - 3.0 microg/L. The mean recoveries of the pesticides were 75% - 119% with the relative standard deviation values less than 16.6% except for dimethoate. The performance of the analyte protectants was compared with matrix-matched standards calibration curves in terms of quantitative accuracy. The results showed that the method of adding analyte protectants can replace the matrix-matched standard calibration, and can also reduce the sample pretreatment. When the devel- oped method was used for the analysis of apple, peache, orange, banana, grape and other fruit samples, a good matrix compensation effect was achieved, and thus effectively reduced the bad effects of the water-soluble agents to the gas chromatographic column.

  13. Multicomponent quantitative spectroscopic analysis without reference substances based on ICA modelling.

    PubMed

    Monakhova, Yulia B; Mushtakova, Svetlana P

    2017-05-01

    A fast and reliable spectroscopic method for multicomponent quantitative analysis of targeted compounds with overlapping signals in complex mixtures has been established. The innovative analytical approach is based on the preliminary chemometric extraction of qualitative and quantitative information from UV-vis and IR spectral profiles of a calibration system using independent component analysis (ICA). Using this quantitative model and ICA resolution results of spectral profiling of "unknown" model mixtures, the absolute analyte concentrations in multicomponent mixtures and authentic samples were then calculated without reference solutions. Good recoveries generally between 95% and 105% were obtained. The method can be applied to any spectroscopic data that obey the Beer-Lambert-Bouguer law. The proposed method was tested on analysis of vitamins and caffeine in energy drinks and aromatic hydrocarbons in motor fuel with 10% error. The results demonstrated that the proposed method is a promising tool for rapid simultaneous multicomponent analysis in the case of spectral overlap and the absence/inaccessibility of reference materials.

  14. Improving the efficiency of quantitative (1)H NMR: an innovative external standard-internal reference approach.

    PubMed

    Huang, Yande; Su, Bao-Ning; Ye, Qingmei; Palaniswamy, Venkatapuram A; Bolgar, Mark S; Raglione, Thomas V

    2014-01-01

    The classical internal standard quantitative NMR (qNMR) method determines the purity of an analyte by the determination of a solution containing the analyte and a standard. Therefore, the standard must meet the requirements of chemical compatibility and lack of resonance interference with the analyte as well as a known purity. The identification of such a standard can be time consuming and must be repeated for each analyte. In contrast, the external standard qNMR method utilizes a standard with a known purity to calibrate the NMR instrument. The external standard and the analyte are measured separately, thereby eliminating the matter of chemical compatibility and resonance interference between the standard and the analyte. However, the instrumental factors, including the quality of NMR tubes, must be kept the same. Any deviations will compromise the accuracy of the results. An innovative qNMR method reported herein utilizes an internal reference substance along with an external standard to assume the role of the standard used in the traditional internal standard qNMR method. In this new method, the internal reference substance must only be chemically compatible and be free of resonance-interference with the analyte or external standard whereas the external standard must only be of a known purity. The exact purity or concentration of the internal reference substance is not required as long as the same quantity is added to the external standard and the analyte. The new method reduces the burden of searching for an appropriate standard for each analyte significantly. Therefore the efficiency of the qNMR purity assay increases while the precision of the internal standard method is retained. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Advantages of using tetrahydrofuran-water as mobile phases in the quantitation of cyclosporin A in monkey and rat plasma by liquid chromatography-tandem mass spectrometry.

    PubMed

    Li, Austin C; Li, Yinghe; Guirguis, Micheal S; Caldwell, Robert G; Shou, Wilson Z

    2007-01-04

    A new analytical method is described here for the quantitation of anti-inflammatory drug cyclosporin A (CyA) in monkey and rat plasma. The method used tetrahydrofuran (THF)-water mobile phases to elute the analyte and internal standard, cyclosporin C (CyC). The gradient mobile phase program successfully eluted CyA into a sharp peak and therefore improved resolution between the analyte and possible interfering materials compared with previously reported analytical approaches, where CyA was eluted as a broad peak due to the rapid conversion between different conformers. The sharp peak resulted from this method facilitated the quantitative calculation as multiple smoothing and large number of bunching factors were not necessary. The chromatography in the new method was performed at 30 degrees C instead of 65-70 degrees C as reported previously. Other advantages of the method included simple and fast sample extraction-protein precipitation, direct injection of the extraction supernatant to column for analysis, and elimination of evaporation and reconstitution steps, which were needed in solid phase extraction or liquid-liquid extraction reported before. This method is amenable to high-throughput analysis with a total chromatographic run time of 3 min. This approach has been verified as sensitive, linear (0.977-4000 ng/mL), accurate and precise for the quantitation of CyA in monkey and rat plasma. However, compared with the usage of conventional mobile phases, the only drawback of this approach was the reduced detection response from the mass spectrometer that was possibly caused by poor desolvation in the ionization source. This is the first report to demonstrate the advantages of using THF-water mobile phases to elute CyA in liquid chromatography.

  16. Quantitative Comparison of Three Standardization Methods Using a One-Way ANOVA for Multiple Mean Comparisons

    ERIC Educational Resources Information Center

    Barrows, Russell D.

    2007-01-01

    A one-way ANOVA experiment is performed to determine whether or not the three standardization methods are statistically different in determining the concentration of the three paraffin analytes. The laboratory exercise asks students to combine the three methods in a single analytical procedure of their own design to determine the concentration of…

  17. High Performance Liquid Chromatography of Vitamin A: A Quantitative Determination.

    ERIC Educational Resources Information Center

    Bohman, Ove; And Others

    1982-01-01

    Experimental procedures are provided for the quantitative determination of Vitamin A (retinol) in food products by analytical liquid chromatography. Standard addition and calibration curve extraction methods are outlined. (SK)

  18. Tannin structural elucidation and quantitative ³¹P NMR analysis. 2. Hydrolyzable tannins and proanthocyanidins.

    PubMed

    Melone, Federica; Saladino, Raffaele; Lange, Heiko; Crestini, Claudia

    2013-10-02

    An unprecedented analytical method that allows simultaneous structural and quantitative characterization of all functional groups present in tannins is reported. In situ labeling of all labile H groups (aliphatic and phenolic hydroxyls and carboxylic acids) with a phosphorus-containing reagent (Cl-TMDP) followed by quantitative ³¹P NMR acquisition constitutes a novel fast and reliable analytical tool for the analysis of tannins and proanthocyanidins with significant implications for the fields of food and feed analyses, tannery, and the development of natural polyphenolics containing products.

  19. A Methodology for Conducting Integrative Mixed Methods Research and Data Analyses

    PubMed Central

    Castro, Felipe González; Kellison, Joshua G.; Boyd, Stephen J.; Kopak, Albert

    2011-01-01

    Mixed methods research has gained visibility within the last few years, although limitations persist regarding the scientific caliber of certain mixed methods research designs and methods. The need exists for rigorous mixed methods designs that integrate various data analytic procedures for a seamless transfer of evidence across qualitative and quantitative modalities. Such designs can offer the strength of confirmatory results drawn from quantitative multivariate analyses, along with “deep structure” explanatory descriptions as drawn from qualitative analyses. This article presents evidence generated from over a decade of pilot research in developing an integrative mixed methods methodology. It presents a conceptual framework and methodological and data analytic procedures for conducting mixed methods research studies, and it also presents illustrative examples from the authors' ongoing integrative mixed methods research studies. PMID:22167325

  20. Problem-based learning on quantitative analytical chemistry course

    NASA Astrophysics Data System (ADS)

    Fitri, Noor

    2017-12-01

    This research applies problem-based learning method on chemical quantitative analytical chemistry, so called as "Analytical Chemistry II" course, especially related to essential oil analysis. The learning outcomes of this course include aspects of understanding of lectures, the skills of applying course materials, and the ability to identify, formulate and solve chemical analysis problems. The role of study groups is quite important in improving students' learning ability and in completing independent tasks and group tasks. Thus, students are not only aware of the basic concepts of Analytical Chemistry II, but also able to understand and apply analytical concepts that have been studied to solve given analytical chemistry problems, and have the attitude and ability to work together to solve the problems. Based on the learning outcome, it can be concluded that the problem-based learning method in Analytical Chemistry II course has been proven to improve students' knowledge, skill, ability and attitude. Students are not only skilled at solving problems in analytical chemistry especially in essential oil analysis in accordance with local genius of Chemistry Department, Universitas Islam Indonesia, but also have skilled work with computer program and able to understand material and problem in English.

  1. Quantitative 1H NMR: Development and Potential of an Analytical Method – an Update

    PubMed Central

    Pauli, Guido F.; Gödecke, Tanja; Jaki, Birgit U.; Lankin, David C.

    2012-01-01

    Covering the literature from mid-2004 until the end of 2011, this review continues a previous literature overview on quantitative 1H NMR (qHNMR) methodology and its applications in the analysis of natural products (NPs). Among the foremost advantages of qHNMR is its accurate function with external calibration, the lack of any requirement for identical reference materials, a high precision and accuracy when properly validated, and an ability to quantitate multiple analytes simultaneously. As a result of the inclusion of over 170 new references, this updated review summarizes a wealth of detailed experiential evidence and newly developed methodology that supports qHNMR as a valuable and unbiased analytical tool for natural product and other areas of research. PMID:22482996

  2. Analytical insight into "breathing" crack-induced acoustic nonlinearity with an application to quantitative evaluation of contact cracks.

    PubMed

    Wang, Kai; Liu, Menglong; Su, Zhongqing; Yuan, Shenfang; Fan, Zheng

    2018-08-01

    To characterize fatigue cracks, in the undersized stage in particular, preferably in a quantitative and precise manner, a two-dimensional (2D) analytical model is developed for interpreting the modulation mechanism of a "breathing" crack on guided ultrasonic waves (GUWs). In conjunction with a modal decomposition method and a variational principle-based algorithm, the model is capable of analytically depicting the propagating and evanescent waves induced owing to the interaction of probing GUWs with a "breathing" crack, and further extracting linear and nonlinear wave features (e.g., reflection, transmission, mode conversion and contact acoustic nonlinearity (CAN)). With the model, a quantitative correlation between CAN embodied in acquired GUWs and crack parameters (e.g., location and severity) is obtained, whereby a set of damage indices is proposed via which the severity of the crack can be evaluated quantitatively. The evaluation, in principle, does not entail a benchmarking process against baseline signals. As validation, the results obtained from the analytical model are compared with those from finite element simulation, showing good consistency. This has demonstrated accuracy of the developed analytical model in interpreting contact crack-induced CAN, and spotlighted its application to quantitative evaluation of fatigue damage. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Quantitative Determination of Fluorinated Alkyl Substances by Large-Volume-Injection LC/MS/MS—Characterization of Municipal Wastewaters

    PubMed Central

    Schultz, Melissa M.; Barofsky, Douglas F.; Field, Jennifer A.

    2008-01-01

    A quantitative method was developed for the determination of fluorinated alkyl substances in municipal wastewater influents and effluents. The method consisted of centrifugation followed by large-volume injection (500 μL) of the supernatant onto a liquid chromatograph with a reverse-phase column and detection by electrospray ionization, and tandem mass spectrometry (LC/MS/MS). The fluorinated analytes studied include perfluoroalkyl sulfonates, fluorotelomer sulfonates, perfluorocarboxylates, and select fluorinated alkyl sulfonamides. Recoveries of the fluorinated analytes from wastewater treatment plant (WWTP) raw influents and final effluent ranged from 77% – 96% and 80% – 99%, respectively. The lower limit of quantitation ranged from 0.5 to 3.0 ng/L depending on the analyte. The method was applied to flow-proportional composites of raw influent and final effluent collected over a 24 hr period from ten WWTPs nationwide. Fluorinated alkyl substances were observed in wastewater at all treatment plants and each plant exhibited unique distributions of fluorinated alkyl substances despite similarities in treatment processes. In nine out of the ten plants sampled, at least one class of fluorinated alkyl substances exhibited increased concentrations in the effluent as compared to the influent concentrations. In some instances, decreases in certain fluorinated analyte concentrations were observed and attributed to sorption to sludge. PMID:16433363

  4. Orthogonal analytical methods for botanical standardization: Determination of green tea catechins by qNMR and LC-MS/MS

    PubMed Central

    Napolitano, José G.; Gödecke, Tanja; Lankin, David C.; Jaki, Birgit U.; McAlpine, James B.; Chen, Shao-Nong; Pauli, Guido F.

    2013-01-01

    The development of analytical methods for parallel characterization of multiple phytoconstituents is essential to advance the quality control of herbal products. While chemical standardization is commonly carried out by targeted analysis using gas or liquid chromatography-based methods, more universal approaches based on quantitative 1H NMR (qHNMR) measurements are being used increasingly in the multi-targeted assessment of these complex mixtures. The present study describes the development of a 1D qHNMR-based method for simultaneous identification and quantification of green tea constituents. This approach utilizes computer-assisted 1H iterative Full Spin Analysis (HiFSA) and enables rapid profiling of seven catechins in commercial green tea extracts. The qHNMR results were cross-validated against quantitative profiles obtained with an orthogonal LC-MS/MS method. The relative strengths and weaknesses of both approaches are discussed, with special emphasis on the role of identical reference standards in qualitative and quantitative analyses. PMID:23870106

  5. A quantitative method for residues of macrolide antibiotics in porcine kidney by liquid chromatography/tandem mass spectrometry.

    PubMed

    Dickson, Leslie C; O'Byrne, Collin; Chan, Wayne

    2012-01-01

    An LC/MS/MS-based multiresidue quantitative method was developed for the macrolides erythromycin A, neospiramycin I, oleandomycin, spiramycin I, tilmicosin, and tylosin A in porcine kidney tissues. The Canadian Food Inspection Agency (CFIA) had as part of its analytical scope an LC/UV method for quantification of residues of two macrolide antibiotics, tilmicosin and tylosin A, in the kidney, liver, and muscle of cattle, swine, and poultry. The method could not reliably detect concentrations below 10 microg/kg. To increase the scope of the CFIA's analytical capabilities, a sensitive multiresidue quantitative method for macrolide residues in food animal tissues was required. Porcine kidney samples were extracted with acetonitrile and alkaline buffer and cleaned-up using silica-based C18 SPE cartridges. Sample extracts were analyzed using LC/MS/MS with positive electrospray ionization. Fitness for purpose was verified in a single-laboratory validation study using a second analyst. The working analytical range was 5 to 50 microg/kg. LOD and LOQ were 0.5 to 0.6 microg/kg and 1.5 to 3.0 microg/kg, respectively. Limits of identification were 0.5 to 2.0 microg/kg. Relative intermediate precisions were 8 to 17%. Average absolute recoveries were 68 to 76%.

  6. Knowledge, Skills, and Abilities for Entry-Level Business Analytics Positions: A Multi-Method Study

    ERIC Educational Resources Information Center

    Cegielski, Casey G.; Jones-Farmer, L. Allison

    2016-01-01

    It is impossible to deny the significant impact from the emergence of big data and business analytics on the fields of Information Technology, Quantitative Methods, and the Decision Sciences. Both industry and academia seek to hire talent in these areas with the hope of developing organizational competencies. This article describes a multi-method…

  7. A Meta-Analytic Review of Studies of the Effectiveness of Small-Group Learning Methods on Statistics Achievement

    ERIC Educational Resources Information Center

    Kalaian, Sema A.; Kasim, Rafa M.

    2014-01-01

    This meta-analytic study focused on the quantitative integration and synthesis of the accumulated pedagogical research in undergraduate statistics education literature. These accumulated research studies compared the academic achievement of students who had been instructed using one of the various forms of small-group learning methods to those who…

  8. Evaluation of a hydrophilic interaction liquid chromatography design space for sugars and sugar alcohols.

    PubMed

    Hetrick, Evan M; Kramer, Timothy T; Risley, Donald S

    2017-03-17

    Based on a column-screening exercise, a column ranking system was developed for sample mixtures containing any combination of 26 sugar and sugar alcohol analytes using 16 polar stationary phases in the HILIC mode with acetonitrile/water or acetone/water mobile phases. Each analyte was evaluated on the HILIC columns with gradient elution and the subsequent chromatography data was compiled into a statistical software package where any subset of the analytes can be selected and the columns are then ranked by the greatest separation. Since these analytes lack chromophores, aerosol-based detectors, including an evaporative light scattering detector (ELSD) and a charged aerosol detector (CAD) were employed for qualitative and quantitative detection. Example qualitative applications are provided to illustrate the practicality and efficiency of this HILIC column ranking. Furthermore, the design-space approach was used as a starting point for a quantitative method for the trace analysis of glucose in trehalose samples in a complex matrix. Knowledge gained from evaluating the design-space led to rapid development of a capable method as demonstrated through validation of the following parameters: specificity, accuracy, precision, linearity, limit of quantitation, limit of detection, and range. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Multi-allergen Quantitation and the Impact of Thermal Treatment in Industry-Processed Baked Goods by ELISA and Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Parker, Christine H; Khuda, Sefat E; Pereira, Marion; Ross, Mark M; Fu, Tong-Jen; Fan, Xuebin; Wu, Yan; Williams, Kristina M; DeVries, Jonathan; Pulvermacher, Brian; Bedford, Binaifer; Zhang, Xi; Jackson, Lauren S

    2015-12-16

    Undeclared food allergens account for 30-40% of food recalls in the United States. Compliance with ingredient labeling regulations and the implementation of effective manufacturing allergen control plans require the use of reliable methods for allergen detection and quantitation in complex food products. The objectives of this work were to (1) produce industry-processed model foods incurred with egg, milk, and peanut allergens, (2) compare analytical method performance for allergen quantitation in thermally processed bakery products, and (3) determine the effects of thermal treatment on allergen detection. Control and allergen-incurred cereal bars and muffins were formulated in a pilot-scale industry processing facility. Quantitation of egg, milk, and peanut in incurred baked goods was compared at various processing stages using commercial enzyme-linked immunosorbent assay (ELISA) kits and a novel multi-allergen liquid chromatography (LC)-tandem mass spectrometry (MS/MS) multiple-reaction monitoring (MRM) method. Thermal processing was determined to negatively affect the recovery and quantitation of egg, milk, and peanut to different extents depending on the allergen, matrix, and analytical test method. The Morinaga ELISA and LC-MS/MS quantitative methods reported the highest recovery across all monitored allergens, whereas the ELISA Systems, Neogen BioKits, Neogen Veratox, and R-Biopharm ELISA Kits underperformed in the determination of allergen content of industry-processed bakery products.

  10. Accurate quantification of PGE2 in the polyposis in rat colon (Pirc) model by surrogate analyte-based UPLC-MS/MS.

    PubMed

    Yun, Changhong; Dashwood, Wan-Mohaiza; Kwong, Lawrence N; Gao, Song; Yin, Taijun; Ling, Qinglan; Singh, Rashim; Dashwood, Roderick H; Hu, Ming

    2018-01-30

    An accurate and reliable UPLC-MS/MS method is reported for the quantification of endogenous Prostaglandin E2 (PGE 2 ) in rat colonic mucosa and polyps. This method adopted the "surrogate analyte plus authentic bio-matrix" approach, using two different stable isotopic labeled analogs - PGE 2 -d9 as the surrogate analyte and PGE 2 -d4 as the internal standard. A quantitative standard curve was constructed with the surrogate analyte in colonic mucosa homogenate, and the method was successfully validated with the authentic bio-matrix. Concentrations of endogenous PGE 2 in both normal and inflammatory tissue homogenates were back-calculated based on the regression equation. Because of no endogenous interference on the surrogate analyte determination, the specificity was particularly good. By using authentic bio-matrix for validation, the matrix effect and exaction recovery are identically same for the quantitative standard curve and actual samples - this notably increased the assay accuracy. The method is easy, fast, robust and reliable for colon PGE 2 determination. This "surrogate analyte" approach was applied to measure the Pirc (an Apc-mutant rat kindred that models human FAP) mucosa and polyps PGE 2 , one of the strong biomarkers of colorectal cancer. A similar concept could be applied to endogenous biomarkers in other tissues. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. A rapid quantitative analysis of bile acids, lysophosphatidylcholines and polyunsaturated fatty acids in biofluids based on ultraperformance liquid chromatography coupled with triple quadrupole tandem massspectrometry.

    PubMed

    Peng, Zhangxiao; Zhang, Qian; Mao, Ziming; Wang, Jie; Liu, Chunying; Lin, Xuejing; Li, Xin; Ji, Weidan; Fan, Jianhui; Wang, Maorong; Su, Changqing

    2017-11-15

    Much evidence suggested that quantitative analysis of bile acids (BAs), lysophosphatidylcholines (LPCs), and polyunsaturated fatty acids (PUFAs) in biofluids may be very useful for diagnosis and prevention of hepatobiliary disease with a non-invasive manner. However, simultaneously fast analysis of these metabolites has been challenging for their huge differences of physicochemical properties and concentration levels in biofluids. In this study, we present a liquid chromatography-mass spectrometry method with a high throughput analytical cycle (10min) to fast and accurately quantify fifteen potential biomarkers (eight BAs, four LPCs and three PUFAs) of hepatobiliary disease. The accuracy for the fifteen analytes in plasma and urine matrices was 80.45%-118.99% and 84.55%-112.66%, respectively. The intra- and inter- precisions for the fifteen analytes in plasma and urine matrices were all less than 20% and the lower limit of quantification (LLOQ) of analytes is up to 0.0283-8.2172nmol/L. Therefore, this method is fast, sensitive and accurate for the quantitative analysis of BAs, LPCs and PUFAs in biofluids. Moreover, the stability and concentration differences of the analytes in plasma and serum were evaluated, and the results demonstrated that LPCs is stable, but PUFAs is very unstable in freeze and thaw cycles, and the concentrations of the analytes in serum were slightly higher than those in plasma. We suggested plasma may be a kind of better bio-sample than serum using for quantitative analysis of metabolites in blood, due to the characteristics of plasma are more close to blood than those of serum. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Dextroamphetamine: a pharmacologic countermeasure for space motion sickness and orthostatic dysfunction

    NASA Technical Reports Server (NTRS)

    Snow, L. Dale

    1996-01-01

    Dextroamphetamine has potential as a pharmacologic agent for the alleviation of two common health effects associated with microgravity. As an adjuvant to Space Motion Sickness (SMS) medication, dextroamphetamine can enhance treatment efficacy by reducing undesirable Central Nervous System (CNS) side effects of SMS medications. Secondly, dextroamphetamine may be useful for the prevention of symptoms of post-mission orthostatic intolerance caused by cardiovascular deconditioning during spaceflight. There is interest in developing an intranasal delivery form of dextroamphetanmine for use as a countermeasure in microgravity conditions. Development of this dosage form will require an analytical detection method with sensitivity in the low ng range (1 to 100 ng/mL). During the 1995 Summer Faculty Fellowship Program, two analytical methods were developed and evaluated for their suitability as quantitative procedures for dextroamphetamine in studies of product stability, bioavailability assessment, and pharmacokinetic evaluation. In developing some of the analytical methods, beta-phenylethylamine, a primary amine structurally similar to dextroamphetamine, was used. The first analytical procedure to be evaluated involved hexane extraction and subsequent fluorescamine labeling of beta-phenylethylamine. The second analytical procedure to be evaluated involved quantitation of dextroamphetamine by an Enzyme-Linked ImmunoSorbent Assay (ELISA).

  13. Targeted methods for quantitative analysis of protein glycosylation

    PubMed Central

    Goldman, Radoslav; Sanda, Miloslav

    2018-01-01

    Quantification of proteins by LC-MS/MS-MRM has become a standard method with broad projected clinical applicability. MRM quantification of protein modifications is, however, far less utilized, especially in the case of glycoproteins. This review summarizes current methods for quantitative analysis of protein glycosylation with a focus on MRM methods. We describe advantages of this quantitative approach, analytical parameters that need to be optimized to achieve reliable measurements, and point out the limitations. Differences between major classes of N- and O-glycopeptides are described and class-specific glycopeptide assays are demonstrated. PMID:25522218

  14. Quantitative Evaluation of the Use of Actigraphy for Neurological and Psychiatric Disorders

    PubMed Central

    Song, Yu; Kwak, Shin; Yoshida, Sohei; Yamamoto, Yoshiharu

    2014-01-01

    Quantitative and objective evaluation of disease severity and/or drug effect is necessary in clinical practice. Wearable accelerometers such as an actigraph enable long-term recording of a patient's movement during activities and they can be used for quantitative assessment of symptoms due to various diseases. We reviewed some applications of actigraphy with analytical methods that are sufficiently sensitive and reliable to determine the severity of diseases and disorders such as motor and nonmotor disorders like Parkinson's disease, sleep disorders, depression, behavioral and psychological symptoms of dementia (BPSD) for vascular dementia (VD), seasonal affective disorder (SAD), and stroke, as well as the effects of drugs used to treat them. We believe it is possible to develop analytical methods to assess more neurological or psychopathic disorders using actigraphy records. PMID:25214709

  15. Quantitative interference by cysteine and N-acetylcysteine metabolites during the LC-MS/MS bioanalysis of a small molecule.

    PubMed

    Barricklow, Jason; Ryder, Tim F; Furlong, Michael T

    2009-08-01

    During LC-MS/MS quantification of a small molecule in human urine samples from a clinical study, an unexpected peak was observed to nearly co-elute with the analyte of interest in many study samples. Improved chromatographic resolution revealed the presence of at least 3 non-analyte peaks, which were identified as cysteine metabolites and N-acetyl (mercapturic acid) derivatives thereof. These metabolites produced artifact responses in the parent compound MRM channel due to decomposition in the ionization source of the mass spectrometer. Quantitative comparison of the analyte concentrations in study samples using the original chromatographic method and the improved chromatographic separation method demonstrated that the original method substantially over-estimated the analyte concentration in many cases. The substitution of electrospray ionization (ESI) for atmospheric pressure chemical ionization (APCI) nearly eliminated the source instability of these metabolites, which would have mitigated their interference in the quantification of the analyte, even without chromatographic separation. These results 1) demonstrate the potential for thiol metabolite interferences during the quantification of small molecules in pharmacokinetic samples, and 2) underscore the need to carefully evaluate LC-MS/MS methods for molecules that can undergo metabolism to thiol adducts to ensure that they are not susceptible to such interferences during quantification.

  16. Quantitative PCR for Genetic Markers of Human Fecal Pollution

    EPA Science Inventory

    Assessment of health risk and fecal bacteria loads associated with human fecal pollution requires reliable host-specific analytical methods and a rapid quantificationapproach. We report the development of quantitative PCR assays for quantification of two recently described human-...

  17. Quantitative methods for analysing cumulative effects on fish migration success: a review.

    PubMed

    Johnson, J E; Patterson, D A; Martins, E G; Cooke, S J; Hinch, S G

    2012-07-01

    It is often recognized, but seldom addressed, that a quantitative assessment of the cumulative effects, both additive and non-additive, of multiple stressors on fish survival would provide a more realistic representation of the factors that influence fish migration. This review presents a compilation of analytical methods applied to a well-studied fish migration, a more general review of quantitative multivariable methods, and a synthesis on how to apply new analytical techniques in fish migration studies. A compilation of adult migration papers from Fraser River sockeye salmon Oncorhynchus nerka revealed a limited number of multivariable methods being applied and the sub-optimal reliance on univariable methods for multivariable problems. The literature review of fisheries science, general biology and medicine identified a large number of alternative methods for dealing with cumulative effects, with a limited number of techniques being used in fish migration studies. An evaluation of the different methods revealed that certain classes of multivariable analyses will probably prove useful in future assessments of cumulative effects on fish migration. This overview and evaluation of quantitative methods gathered from the disparate fields should serve as a primer for anyone seeking to quantify cumulative effects on fish migration survival. © 2012 The Authors. Journal of Fish Biology © 2012 The Fisheries Society of the British Isles.

  18. Multiple animal studies for medical chemical defense program in soldier/patient decontamination and drug development on task 85-17: Validation of an analytical method for the detection of soman (GD), mustard (HD), tabun (GA), and VX in wastewater samples. Final report, 13 October 1985-1 January 1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joiner, R.L.; Hayes, L.; Rust, W.

    1989-05-01

    The following report summarizes the development and validation of an analytical method for the analyses of soman (GD), mustard (HD), VX, and tabun (GA) in wastewater. The need for an analytical method that can detect GD, HD, VX, and GA with the necessary sensitivity (< 20 parts per billion (PPB))and selectivity is essential to Medical Research and Evaluation Facility (MREF) operations. The analytical data were generated using liquid-liquid extraction of the wastewater, with the extract being concentrated and analyzed by gas chromatography (GC) methods. The sample preparation and analyses methods were developed in support of ongoing activities within the MREF.more » We have documented the precision and accuracy of the analytical method through an expected working calibration range (3.0 to 60 ppb). The analytical method was statistically evaluated over a range of concentrations to establish a detection limit and quantitation limit for the method. Whenever the true concentration is 8.5 ppb or above, the probability is at least 99.9 percent that the measured concentration will be ppb or above. Thus, 6 ppb could be used as a lower reliability limit for detecting concentrations in excess of 8.5 ppb. In summary, the proposed sample extraction and analyses methods are suitable for quantitative analyses to determine the presence of GD, HD, VX, and GA in wastewater samples. Our findings indicate that we can detect any of these chemical surety materiel (CSM) in water at or below the established U.S. Army Surgeon General's safety levels in drinking water.« less

  19. Selection of Wavelengths for Optimum Precision in Simultaneous Spectrophotometric Determinations.

    ERIC Educational Resources Information Center

    DiTusa, Michael R.; Schilt, Alfred A.

    1985-01-01

    Although many textbooks include a description of simultaneous determinations employing absorption spectrophotometry and treat the mathematics necessary for analytical quantitations, treatment of analytical wavelength selection has been mostly qualitative. Therefore, a general method for selecting wavelengths for optimum precision in simultaneous…

  20. Quantitative PCR for genetic markers of human fecal pollution

    EPA Science Inventory

    Assessment of health risk and fecal bacteria loads associated with human fecal pollution requires reliable host-specific analytical methods and a rapid quantification approach. We report the development of quantitative PCR assays for enumeration of two recently described hum...

  1. Quantitative Determination of α-Arbutin, β-Arbutin, Kojic Acid, Nicotinamide, Hydroquinone, Resorcinol, 4-Methoxyphenol, 4-Ethoxyphenol, and Ascorbic Acid from Skin Whitening Products by HPLC-UV.

    PubMed

    Wang, Yan-Hong; Avonto, Cristina; Avula, Bharathi; Wang, Mei; Rua, Diego; Khan, Ikhlas A

    2015-01-01

    An HPLC-UV method was developed for the quantitative analysis of nine skin whitening agents in a single injection. These compounds are α-arbutin, β-arbutin, kojic acid, nicotinamide, resorcinol, ascorbic acid, hydroquinone, 4-methoxyphenol, and 4-ethoxyphenol. The separation was achieved on a reversed-phase C18 column within 30 min. The mobile phase was composed of water and methanol, both containing 0.1% acetic acid (v/v). The stability of the analytes was evaluated at different pH values between 2.3 and 7.6, and the extraction procedure was validated for different types of skin whitening product matrixes, which included two creams, a soap bar, and a capsule. The best solvent system for sample preparation was 20 mM NaH2PO4 containing 10% methanol at pH 2.3. The analytical method was validated for accuracy, precision, LOD, and LOQ. The developed HPLC-UV method was applied for the quantitation of the nine analytes in 59 skin whitening products including creams, lotions, sera, foams, gels, mask sheets, soap bars, tablets, and capsules.

  2. Multiple internal standard normalization for improving HS-SPME-GC-MS quantitation in virgin olive oil volatile organic compounds (VOO-VOCs) profile.

    PubMed

    Fortini, Martina; Migliorini, Marzia; Cherubini, Chiara; Cecchi, Lorenzo; Calamai, Luca

    2017-04-01

    The commercial value of virgin olive oils (VOOs) strongly depends on their classification, also based on the aroma of the oils, usually evaluated by a panel test. Nowadays, a reliable analytical method is still needed to evaluate the volatile organic compounds (VOCs) and support the standard panel test method. To date, the use of HS-SPME sampling coupled to GC-MS is generally accepted for the analysis of VOCs in VOOs. However, VOO is a challenging matrix due to the simultaneous presence of: i) compounds at ppm and ppb concentrations; ii) molecules belonging to different chemical classes and iii) analytes with a wide range of molecular mass. Therefore, HS-SPME-GC-MS quantitation based upon the use of external standard method or of only a single internal standard (ISTD) for data normalization in an internal standard method, may be troublesome. In this work a multiple internal standard normalization is proposed to overcome these problems and improving quantitation of VOO-VOCs. As many as 11 ISTDs were used for quantitation of 71 VOCs. For each of them the most suitable ISTD was selected and a good linearity in a wide range of calibration was obtained. Except for E-2-hexenal, without ISTD or with an unsuitable ISTD, the linear range of calibration was narrower with respect to that obtained by a suitable ISTD, confirming the usefulness of multiple internal standard normalization for the correct quantitation of VOCs profile in VOOs. The method was validated for 71 VOCs, and then applied to a series of lampante virgin olive oils and extra virgin olive oils. In light of our results, we propose the application of this analytical approach for routine quantitative analyses and to support sensorial analysis for the evaluation of positive and negative VOOs attributes. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Spectroscopic characterization and quantitative determination of atorvastatin calcium impurities by novel HPLC method

    NASA Astrophysics Data System (ADS)

    Gupta, Lokesh Kumar

    2012-11-01

    Seven process related impurities were identified by LC-MS in the atorvastatin calcium drug substance. These impurities were identified by LC-MS. The structure of impurities was confirmed by modern spectroscopic techniques like 1H NMR and IR and physicochemical studies conducted by using synthesized authentic reference compounds. The synthesized reference samples of the impurity compounds were used for the quantitative HPLC determination. These impurities were detected by newly developed gradient, reverse phase high performance liquid chromatographic (HPLC) method. The system suitability of HPLC analysis established the validity of the separation. The analytical method was validated according to International Conference of Harmonization (ICH) with respect to specificity, precision, accuracy, linearity, robustness and stability of analytical solutions to demonstrate the power of newly developed HPLC method.

  4. Conflagration Analysis System II: Bibliography.

    DTIC Science & Technology

    1985-04-01

    Therefore, it is Lmportant to examine both the reinforcement and the supplemental considerations Eor the quantitative methods for conflagration...and the meaningful quantitative factors for conflagration analysis are determined, the relevatn literature will be brought into the nainstream of the... quantitative :hods. Fire Development in Multiple Structures From a purely analytical view, the research identified in the literature fire development in

  5. Comparing Online with Brick and Mortar Course Learning Outcomes: An Analysis of Quantitative Methods Curriculum in Public Administration

    ERIC Educational Resources Information Center

    Harris, Ronald A.; Nikitenko, Gleb O.

    2014-01-01

    Teaching graduate students in an intensive adult-learning format presents a special challenge for quantitative analytical competencies. Students often lack necessary background, skills and motivation to deal with quantitative-skill-based course work. This study compares learning outcomes for graduate students enrolled in three course sections…

  6. Analytical methods for toxic gases from thermal degradation of polymers

    NASA Technical Reports Server (NTRS)

    Hsu, M.-T. S.

    1977-01-01

    Toxic gases evolved from the thermal oxidative degradation of synthetic or natural polymers in small laboratory chambers or in large scale fire tests are measured by several different analytical methods. Gas detector tubes are used for fast on-site detection of suspect toxic gases. The infrared spectroscopic method is an excellent qualitative and quantitative analysis for some toxic gases. Permanent gases such as carbon monoxide, carbon dioxide, methane and ethylene, can be quantitatively determined by gas chromatography. Highly toxic and corrosive gases such as nitrogen oxides, hydrogen cyanide, hydrogen fluoride, hydrogen chloride and sulfur dioxide should be passed into a scrubbing solution for subsequent analysis by either specific ion electrodes or spectrophotometric methods. Low-concentration toxic organic vapors can be concentrated in a cold trap and then analyzed by gas chromatography and mass spectrometry. The limitations of different methods are discussed.

  7. [The water content reference material of water saturated octanol].

    PubMed

    Wang, Haifeng; Ma, Kang; Zhang, Wei; Li, Zhanyuan

    2011-03-01

    The national standards of biofuels specify the technique specification and analytical methods. A water content certified reference material based on the water saturated octanol was developed in order to satisfy the needs of the instrument calibration and the methods validation, assure the accuracy and consistency of results in water content measurements of biofuels. Three analytical methods based on different theories were employed to certify the water content of the reference material, including Karl Fischer coulometric titration, Karl Fischer volumetric titration and quantitative nuclear magnetic resonance. The consistency of coulometric and volumetric titration was achieved through the improvement of methods. The accuracy of the certified result was improved by the introduction of the new method of quantitative nuclear magnetic resonance. Finally, the certified value of reference material is 4.76% with an expanded uncertainty of 0.09%.

  8. Directivity analysis of meander-line-coil EMATs with a wholly analytical method.

    PubMed

    Xie, Yuedong; Liu, Zenghua; Yin, Liyuan; Wu, Jiande; Deng, Peng; Yin, Wuliang

    2017-01-01

    This paper presents the simulation and experimental study of the radiation pattern of a meander-line-coil EMAT. A wholly analytical method, which involves the coupling of two models: an analytical EM model and an analytical UT model, has been developed to build EMAT models and analyse the Rayleigh waves' beam directivity. For a specific sensor configuration, Lorentz forces are calculated using the EM analytical method, which is adapted from the classic Deeds and Dodd solution. The calculated Lorentz force density are imported to an analytical ultrasonic model as driven point sources, which produce the Rayleigh waves within a layered medium. The effect of the length of the meander-line-coil on the Rayleigh waves' beam directivity is analysed quantitatively and verified experimentally. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Method Development in Forensic Toxicology.

    PubMed

    Peters, Frank T; Wissenbach, Dirk K; Busardo, Francesco Paolo; Marchei, Emilia; Pichini, Simona

    2017-01-01

    In the field of forensic toxicology, the quality of analytical methods is of great importance to ensure the reliability of results and to avoid unjustified legal consequences. A key to high quality analytical methods is a thorough method development. The presented article will provide an overview on the process of developing methods for forensic applications. This includes the definition of the method's purpose (e.g. qualitative vs quantitative) and the analytes to be included, choosing an appropriate sample matrix, setting up separation and detection systems as well as establishing a versatile sample preparation. Method development is concluded by an optimization process after which the new method is subject to method validation. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  10. Quantitative determination of a-Arbutin, ß-Arbutin, Kojic acid, nicotinamide, hydroquinone, resorcinol, 4-methoxyphenol, 4-ethoxyphenol and ascorbic acid from skin whitening Products by HPLC-UV

    USDA-ARS?s Scientific Manuscript database

    Development of an analytical method for the simultaneous determination of multifarious skin whitening agents will provide an efficient tool to analyze skin whitening cosmetics. An HPLC-UV method was developed for quantitative analysis of six commonly used whitening agents, a-arbutin, ß-arbutin, koji...

  11. Fourier Transform Infrared Absorption Spectroscopy for Quantitative Analysis of Gas Mixtures at Low Temperatures for Homeland Security Applications.

    PubMed

    Meier, D C; Benkstein, K D; Hurst, W S; Chu, P M

    2017-05-01

    Performance standard specifications for point chemical vapor detectors are established in ASTM E 2885-13 and ASTM E 2933-13. The performance evaluation of the detectors requires the accurate delivery of known concentrations of the chemical target to the system under test. Referee methods enable the analyte test concentration and associated uncertainties in the analyte test concentration to be validated by independent analysis, which is especially important for reactive analytes. This work extends the capability of a previously demonstrated method for using Fourier transform infrared (FT-IR) absorption spectroscopy for quantitatively evaluating the composition of vapor streams containing hazardous materials at Acute Exposure Guideline Levels (AEGL) to include test conditions colder than laboratory ambient temperatures. The described method covers the use of primary reference spectra to establish analyte concentrations, the generation of secondary reference spectra suitable for measuring analyte concentrations under specified testing environments, and the use of additional reference spectra and spectral profile strategies to mitigate the uncertainties due to impurities and water condensation within the low-temperature (7 °C, -5 °C) test cell. Important benefits of this approach include verification of the test analyte concentration with characterized uncertainties by in situ measurements co-located with the detector under test, near-real-time feedback, and broad applicability to toxic industrial chemicals.

  12. Fourier Transform Infrared Absorption Spectroscopy for Quantitative Analysis of Gas Mixtures at Low Temperatures for Homeland Security Applications

    PubMed Central

    Meier, D.C.; Benkstein, K.D.; Hurst, W.S.; Chu, P.M.

    2016-01-01

    Performance standard specifications for point chemical vapor detectors are established in ASTM E 2885-13 and ASTM E 2933-13. The performance evaluation of the detectors requires the accurate delivery of known concentrations of the chemical target to the system under test. Referee methods enable the analyte test concentration and associated uncertainties in the analyte test concentration to be validated by independent analysis, which is especially important for reactive analytes. This work extends the capability of a previously demonstrated method for using Fourier transform infrared (FT-IR) absorption spectroscopy for quantitatively evaluating the composition of vapor streams containing hazardous materials at Acute Exposure Guideline Levels (AEGL) to include test conditions colder than laboratory ambient temperatures. The described method covers the use of primary reference spectra to establish analyte concentrations, the generation of secondary reference spectra suitable for measuring analyte concentrations under specified testing environments, and the use of additional reference spectra and spectral profile strategies to mitigate the uncertainties due to impurities and water condensation within the low-temperature (7 °C, −5 °C) test cell. Important benefits of this approach include verification of the test analyte concentration with characterized uncertainties by in situ measurements co-located with the detector under test, near-real-time feedback, and broad applicability to toxic industrial chemicals. PMID:28090126

  13. Evaluation and performance of desorption electrospray ionization using a triple quadrupole mass spectrometer for quantitation of pharmaceuticals in plasma.

    PubMed

    Kennedy, Joseph H; Wiseman, Justin M

    2010-02-01

    The present work describes the methodology and investigates the performance of desorption electrospray ionization (DESI) combined with a triple quadrupole mass spectrometer for the quantitation of small drug molecules in human plasma. Amoxepine, atenolol, carbamazepine, clozapine, prazosin, propranolol and verapamil were selected as target analytes while terfenadine was selected as the internal standard common to each of the analytes. Protein precipitation of human plasma using acetonitrile was utilized for all samples. Limits of detection were determined for all analytes in plasma and shown to be in the range 0.2-40 ng/mL. Quantitative analysis of amoxepine, prazosin and verapamil was performed over the range 20-7400 ng/mL and shown to be linear in all cases with R(2) >0.99. In most cases, the precision (relative standard deviation) and accuracy (relative error) of each method were less than or equal to 20%, respectively. The performance of the combined techniques made it possible to analyze each sample in 15 s illustrating DESI tandem mass spectrometry (MS/MS) as powerful tool for the quantitation of analytes in deproteinized human plasma. Copyright 2010 John Wiley & Sons, Ltd.

  14. Simultaneous quantitative analysis of olmesartan, amlodipine and hydrochlorothiazide in their combined dosage form utilizing classical and alternating least squares based chemometric methods.

    PubMed

    Darwish, Hany W; Bakheit, Ahmed H; Abdelhameed, Ali S

    2016-03-01

    Simultaneous spectrophotometric analysis of a multi-component dosage form of olmesartan, amlodipine and hydrochlorothiazide used for the treatment of hypertension has been carried out using various chemometric methods. Multivariate calibration methods include classical least squares (CLS) executed by net analyte processing (NAP-CLS), orthogonal signal correction (OSC-CLS) and direct orthogonal signal correction (DOSC-CLS) in addition to multivariate curve resolution-alternating least squares (MCR-ALS). Results demonstrated the efficiency of the proposed methods as quantitative tools of analysis as well as their qualitative capability. The three analytes were determined precisely using the aforementioned methods in an external data set and in a dosage form after optimization of experimental conditions. Finally, the efficiency of the models was validated via comparison with the partial least squares (PLS) method in terms of accuracy and precision.

  15. [Adequate application of quantitative and qualitative statistic analytic methods in acupuncture clinical trials].

    PubMed

    Tan, Ming T; Liu, Jian-ping; Lao, Lixing

    2012-08-01

    Recently, proper use of the statistical methods in traditional Chinese medicine (TCM) randomized controlled trials (RCTs) has received increased attention. Statistical inference based on hypothesis testing is the foundation of clinical trials and evidence-based medicine. In this article, the authors described the methodological differences between literature published in Chinese and Western journals in the design and analysis of acupuncture RCTs and the application of basic statistical principles. In China, qualitative analysis method has been widely used in acupuncture and TCM clinical trials, while the between-group quantitative analysis methods on clinical symptom scores are commonly used in the West. The evidence for and against these analytical differences were discussed based on the data of RCTs assessing acupuncture for pain relief. The authors concluded that although both methods have their unique advantages, quantitative analysis should be used as the primary analysis while qualitative analysis can be a secondary criterion for analysis. The purpose of this paper is to inspire further discussion of such special issues in clinical research design and thus contribute to the increased scientific rigor of TCM research.

  16. Development of a pressurized liquid extraction-solid-phase extraction followed by liquid chromatography-electrospray ionization tandem mass spectrometry method for the quantitative determination of benzoxazolinones and their degradation products in agricultural soil.

    PubMed

    Villagrasa, M; Guillamón, M; Navarro, A; Eljarrat, E; Barceló, D

    2008-02-01

    A new analytical method for the quantitative determination of benzoxazolinones and their degradation products in agricultural soils based on the use of pressurized liquid extraction (PLE) followed by solid-phase extraction (SPE) and then instrumental determination using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS-MS) is described. Using this method, the characterization, separation and quantitative detection of a mixture of two benzoxazolinones, benzoxazolin-2-one (BOA) and 6-methoxybenzoxazolin-2-one (MBOA) and their degradation products, 2-aminophenol (APH), N-(2-hydroxyphenyl)malonamic acid (HMPMA), 2-amino-3-H-phenoxazin-3-one (APO), 9-methoxy-2-amino-3-H-phenoxazin-3-one (AMPO), 2-acetylamino-3-H-phenoxazin-3-one (AAPO) and 2-acetylamino-9-methoxy-2-amino-3-H-phenoxazin-3-one (AAMPO) was achieved. The complete LC-ESI-MS-MS precursor-product ion fragmentation pathways for the degradation products of benzoxazolinones are described for the first time. Quantitative analysis was done in the multiple reaction mode using two specific combinations of precursor-product ion transitions for each compound. The optimized method was quality assessed by the measure of parameter as recovery, linearity, sensitivity, repeatability and reproducibility. Recoveries of the analytes ranged from 53 to 123%. The developed method offered improvements to the sensitivity as compared with our previously LC-MS method, with detection limits down to 2.4-21 ng/g of dry weight. This achievement allows us to identify and quantify for the first time degradation products of benzoxazolinones in real agricultural soil samples. Analytes were found in the range of 20.6-149 ng/g dry weight.

  17. Combined use of optical and electron microscopic techniques for the measurement of hygroscopic property, chemical composition, and morphology of individual aerosol particles.

    PubMed

    Ahn, Kang-Ho; Kim, Sun-Man; Jung, Hae-Jin; Lee, Mi-Jung; Eom, Hyo-Jin; Maskey, Shila; Ro, Chul-Un

    2010-10-01

    In this work, an analytical method for the characterization of the hygroscopic property, chemical composition, and morphology of individual aerosol particles is introduced. The method, which is based on the combined use of optical and electron microscopic techniques, is simple and easy to apply. An optical microscopic technique was used to perform the visual observation of the phase transformation and hygroscopic growth of aerosol particles on a single particle level. A quantitative energy-dispersive electron probe X-ray microanalysis, named low-Z particle EPMA, was used to perform a quantitative chemical speciation of the same individual particles after the measurement of the hygroscopic property. To validate the analytical methodology, the hygroscopic properties of artificially generated NaCl, KCl, (NH(4))(2)SO(4), and Na(2)SO(4) aerosol particles of micrometer size were investigated. The practical applicability of the analytical method for studying the hygroscopic property, chemical composition, and morphology of ambient aerosol particles is demonstrated.

  18. A method for direct, semi-quantitative analysis of gas phase samples using gas chromatography-inductively coupled plasma-mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carter, Kimberly E; Gerdes, Kirk

    2013-07-01

    A new and complete GC–ICP-MS method is described for direct analysis of trace metals in a gas phase process stream. The proposed method is derived from standard analytical procedures developed for ICP-MS, which are regularly exercised in standard ICP-MS laboratories. In order to implement the method, a series of empirical factors were generated to calibrate detector response with respect to a known concentration of an internal standard analyte. Calibrated responses are ultimately used to determine the concentration of metal analytes in a gas stream using a semi-quantitative algorithm. The method was verified using a traditional gas injection from a GCmore » sampling valve and a standard gas mixture containing either a 1 ppm Xe + Kr mix with helium balance or 100 ppm Xe with helium balance. Data collected for Xe and Kr gas analytes revealed that agreement of 6–20% with the actual concentration can be expected for various experimental conditions. To demonstrate the method using a relevant “unknown” gas mixture, experiments were performed for continuous 4 and 7 hour periods using a Hg-containing sample gas that was co-introduced into the GC sample loop with the xenon gas standard. System performance and detector response to the dilute concentration of the internal standard were pre-determined, which allowed semi-quantitative evaluation of the analyte. The calculated analyte concentrations varied during the course of the 4 hour experiment, particularly during the first hour of the analysis where the actual Hg concentration was under predicted by up to 72%. Calculated concentration improved to within 30–60% for data collected after the first hour of the experiment. Similar results were seen during the 7 hour test with the deviation from the actual concentration being 11–81% during the first hour and then decreasing for the remaining period. The method detection limit (MDL) was determined for the mercury by injecting the sample gas into the system following a period of equilibration. The MDL for Hg was calculated as 6.8 μg · m -3. This work describes the first complete GC–ICP-MS method to directly analyze gas phase samples, and detailed sample calculations and comparisons to conventional ICP-MS methods are provided.« less

  19. Quantitative Determination of Perfluorochemicals and Fluorotelomer Alcohols in Plants from Biosolid-Amended Fields using LC/MS/MS and GC/MS

    EPA Science Inventory

    Analytical methods for determining perfluorochemicals (PFCs) and fluorotelomer alcohols (FTOHs) in plants using liquid chromatography/tandem mass spectrometry (LC/MS/MS) and gas chromatography/mass spectrometry (GC/MS) were developed, and applied to quantify a suite of analytes i...

  20. Infrared Spectroscopy as a Versatile Analytical Tool for the Quantitative Determination of Antioxidants in Agricultural Products, Foods and Plants

    PubMed Central

    Cozzolino, Daniel

    2015-01-01

    Spectroscopic methods provide with very useful qualitative and quantitative information about the biochemistry and chemistry of antioxidants. Near infrared (NIR) and mid infrared (MIR) spectroscopy are considered as powerful, fast, accurate and non-destructive analytical tools that can be considered as a replacement of traditional chemical analysis. In recent years, several reports can be found in the literature demonstrating the usefulness of these methods in the analysis of antioxidants in different organic matrices. This article reviews recent applications of infrared (NIR and MIR) spectroscopy in the analysis of antioxidant compounds in a wide range of samples such as agricultural products, foods and plants. PMID:26783838

  1. Priority survey between indicators and analytic hierarchy process analysis for green chemistry technology assessment

    PubMed Central

    Kim, Sungjune; Hong, Seokpyo; Ahn, Kilsoo; Gong, Sungyong

    2015-01-01

    Objectives This study presents the indicators and proxy variables for the quantitative assessment of green chemistry technologies and evaluates the relative importance of each assessment element by consulting experts from the fields of ecology, chemistry, safety, and public health. Methods The results collected were subjected to an analytic hierarchy process to obtain the weights of the indicators and the proxy variables. Results These weights may prove useful in avoiding having to resort to qualitative means in absence of weights between indicators when integrating the results of quantitative assessment by indicator. Conclusions This study points to the limitations of current quantitative assessment techniques for green chemistry technologies and seeks to present the future direction for quantitative assessment of green chemistry technologies. PMID:26206364

  2. Quantitative correlations between collision induced dissociation mass spectrometry coupled with electrospray ionization or atmospheric pressure chemical ionization mass spectrometry - Experiment and theory

    NASA Astrophysics Data System (ADS)

    Ivanova, Bojidarka; Spiteller, Michael

    2018-04-01

    The problematic that we consider in this paper treats the quantitative correlation model equations between experimental kinetic and thermodynamic parameters of coupled electrospray ionization (ESI) mass spectrometry (MS) or atmospheric pressure chemical ionization (APCI) mass spectrometry with collision induced dissociation mass spectrometry, accounting for the fact that the physical phenomena and mechanisms of ESI- and APCI-ion formation are completely different. There are described forty two fragment reactions of three analytes under independent ESI- and APCI-measurements. The developed new quantitative models allow us to study correlatively the reaction kinetics and thermodynamics using the methods of mass spectrometry, which complementary application with the methods of the quantum chemistry provide 3D structural information of the analytes. Both static and dynamic quantum chemical computations are carried out. The object of analyses are [2,3-dimethyl-4-(4-methyl-benzoyl)-2,3-di-p-tolyl-cyclobutyl]-p-tolyl-methanone (1) and the polycyclic aromatic hydrocarbons derivatives of dibenzoperylen (2) and tetrabenzo [a,c,fg,op]naphthacene (3), respectively. As far as (1) is known to be a product of [2π+2π] cycloaddition reactions of chalcone (1,3-di-p-tolyl-propenone), however producing cyclic derivatives with different stereo selectivity, so that the study provide crucial data about the capability of mass spectrometry to provide determine the stereo selectivity of the analytes. This work also first provides quantitative treatment of the relations '3D molecular/electronic structures'-'quantum chemical diffusion coefficient'-'mass spectrometric diffusion coefficient', thus extending the capability of the mass spectrometry for determination of the exact 3D structure of the analytes using independent measurements and computations of the diffusion coefficients. The determination of the experimental diffusion parameters is carried out within the 'current monitoring method' evaluating the translation diffusion of charged analytes, while the theoretical modelling of MS ions and computations of theoretical diffusion coefficients are based on the Arrhenius type behavior of the charged species under ESI- and APCI-conditions. Although the study provide certain sound considerations for the quantitative relations between the reaction kinetic-thermodynamics and 3D structure of the analytes together with correlations between 3D molecular/electronic structures-quantum chemical diffusion coefficient-mass spectrometric diffusion coefficient, which contribute significantly to the structural analytical chemistry, the results have importance to other areas such as organic synthesis and catalysis as well.

  3. An augmented classical least squares method for quantitative Raman spectral analysis against component information loss.

    PubMed

    Zhou, Yan; Cao, Hui

    2013-01-01

    We propose an augmented classical least squares (ACLS) calibration method for quantitative Raman spectral analysis against component information loss. The Raman spectral signals with low analyte concentration correlations were selected and used as the substitutes for unknown quantitative component information during the CLS calibration procedure. The number of selected signals was determined by using the leave-one-out root-mean-square error of cross-validation (RMSECV) curve. An ACLS model was built based on the augmented concentration matrix and the reference spectral signal matrix. The proposed method was compared with partial least squares (PLS) and principal component regression (PCR) using one example: a data set recorded from an experiment of analyte concentration determination using Raman spectroscopy. A 2-fold cross-validation with Venetian blinds strategy was exploited to evaluate the predictive power of the proposed method. The one-way variance analysis (ANOVA) was used to access the predictive power difference between the proposed method and existing methods. Results indicated that the proposed method is effective at increasing the robust predictive power of traditional CLS model against component information loss and its predictive power is comparable to that of PLS or PCR.

  4. Detection of biological molecules using chemical amplification and optical sensors

    DOEpatents

    Van Antwerp, William Peter; Mastrototaro, John Joseph

    2001-01-01

    Methods are provided for the determination of the concentration of biological levels of polyhydroxylated compounds, particularly glucose. The methods utilize an amplification system that is an analyte transducer immobilized in a polymeric matrix, where the system is implantable and biocompatible. Upon interrogation by an optical system, the amplification system produces a signal capable of detection external to the skin of the patient. Quantitation of the analyte of interest is achieved by measurement of the emitted signal. Specifically, the analyte transducer immobilized in a polymeric matrix can be a boronic acid moiety.

  5. A study of the temporal robustness of the growing global container-shipping network

    PubMed Central

    Wang, Nuo; Wu, Nuan; Dong, Ling-ling; Yan, Hua-kun; Wu, Di

    2016-01-01

    Whether they thrive as they grow must be determined for all constantly expanding networks. However, few studies have focused on this important network feature or the development of quantitative analytical methods. Given the formation and growth of the global container-shipping network, we proposed the concept of network temporal robustness and quantitative method. As an example, we collected container liner companies’ data at two time points (2004 and 2014) and built a shipping network with ports as nodes and routes as links. We thus obtained a quantitative value of the temporal robustness. The temporal robustness is a significant network property because, for the first time, we can clearly recognize that the shipping network has become more vulnerable to damage over the last decade: When the node failure scale reached 50% of the entire network, the temporal robustness was approximately −0.51% for random errors and −12.63% for intentional attacks. The proposed concept and analytical method described in this paper are significant for other network studies. PMID:27713549

  6. Separation and quantitation of three acidic herbicide residues in tobacco and soil by dispersive solid-phase extraction and UPLC-MS/MS.

    PubMed

    Xiong, Wei; Tao, Xiaoqiu; Pang, Su; Yang, Xue; Tang, GangLing; Bian, Zhaoyang

    2014-01-01

    A method for the determination of three acidic herbicides, dicamba, 2,4-dichlorophenoxyacetic acid (2,4-D) and 2,4,5-trichlorophenoxyacetic acid (2,4,5-T) in tobacco and soil has been developed based on the use of liquid-liquid extraction and dispersive solid-phase extraction (dispersive-SPE) followed by UPLC-MS/MS. Two percentage of (v/v) formic acid in acetonitrile as the extraction helped partitioning of analytes into the acetonitrile phase. The extract was then cleaned up by dispersive-SPE using primary secondary amine as selective sorbents. Quantitative analysis was done in the multiple-reaction monitoring mode using stable isotope-labeled internal standards for each compound. A separate internal standard for each analyte is required to minimize sample matrix effects on each analyte, which can lead to poor analyte recoveries and decreases in method accuracy and precision. The total analysis time was <4 min. The linear range of the method was from 1 to 100 ng mL(-1) with a limit of detection of each herbicide varied from 0.012 to 0.126 ng g(-1). The proposed method is faster, more sensitive and selective than the traditional methods and more accurate and robust than the published LC-MS/MS methods. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Mass spectrometry as a quantitative tool in plant metabolomics

    PubMed Central

    Jorge, Tiago F.; Mata, Ana T.

    2016-01-01

    Metabolomics is a research field used to acquire comprehensive information on the composition of a metabolite pool to provide a functional screen of the cellular state. Studies of the plant metabolome include the analysis of a wide range of chemical species with very diverse physico-chemical properties, and therefore powerful analytical tools are required for the separation, characterization and quantification of this vast compound diversity present in plant matrices. In this review, challenges in the use of mass spectrometry (MS) as a quantitative tool in plant metabolomics experiments are discussed, and important criteria for the development and validation of MS-based analytical methods provided. This article is part of the themed issue ‘Quantitative mass spectrometry’. PMID:27644967

  8. Apparatus for rapid measurement of aerosol bulk chemical composition

    DOEpatents

    Lee, Yin-Nan E.; Weber, Rodney J.

    2003-01-01

    An apparatus and method for continuous on-line measurement of chemical composition of aerosol particles with a fast time resolution are provided. The apparatus includes a modified particle size magnifier for producing activated aerosol particles and a collection device which collects the activated aerosol particles into a liquid stream for quantitative analysis by analytical methods. The method provided for on-line measurement of chemical composition of aerosol particles includes exposing aerosol carrying sample air to hot saturated steam thereby forming activated aerosol particles; collecting the activated aerosol particles by a collection device for delivery as a jet stream onto an impaction surface; flushing off the activated aerosol particles from the impaction surface into a liquid stream for delivery of the collected liquid stream to an analytical instrument for quantitative measurement.

  9. Low level vapor verification of monomethyl hydrazine

    NASA Technical Reports Server (NTRS)

    Mehta, Narinder

    1990-01-01

    The vapor scrubbing system and the coulometric test procedure for the low level vapor verification of monomethyl hydrazine (MMH) are evaluated. Experimental data on precision, efficiency of the scrubbing liquid, instrument response, detection and reliable quantitation limits, stability of the vapor scrubbed solution, and interference were obtained to assess the applicability of the method for the low ppb level detection of the analyte vapor in air. The results indicated that the analyte vapor scrubbing system and the coulometric test procedure can be utilized for the quantitative detection of low ppb level vapor of MMH in air.

  10. Comparative spectral analysis of veterinary powder product by continuous wavelet and derivative transforms

    NASA Astrophysics Data System (ADS)

    Dinç, Erdal; Kanbur, Murat; Baleanu, Dumitru

    2007-10-01

    Comparative simultaneous determination of chlortetracycline and benzocaine in the commercial veterinary powder product was carried out by continuous wavelet transform (CWT) and classical derivative transform (or classical derivative spectrophotometry). In this quantitative spectral analysis, two proposed analytical methods do not require any chemical separation process. In the first step, several wavelet families were tested to find an optimal CWT for the overlapping signal processing of the analyzed compounds. Subsequently, we observed that the coiflets (COIF-CWT) method with dilation parameter, a = 400, gives suitable results for this analytical application. For a comparison, the classical derivative spectrophotometry (CDS) approach was also applied to the simultaneous quantitative resolution of the same analytical problem. Calibration functions were obtained by measuring the transform amplitudes corresponding to zero-crossing points for both CWT and CDS methods. The utility of these two analytical approaches were verified by analyzing various synthetic mixtures consisting of chlortetracycline and benzocaine and they were applied to the real samples consisting of veterinary powder formulation. The experimental results obtained from the COIF-CWT approach were statistically compared with those obtained by classical derivative spectrophotometry and successful results were reported.

  11. A novel second-order standard addition analytical method based on data processing with multidimensional partial least-squares and residual bilinearization.

    PubMed

    Lozano, Valeria A; Ibañez, Gabriela A; Olivieri, Alejandro C

    2009-10-05

    In the presence of analyte-background interactions and a significant background signal, both second-order multivariate calibration and standard addition are required for successful analyte quantitation achieving the second-order advantage. This report discusses a modified second-order standard addition method, in which the test data matrix is subtracted from the standard addition matrices, and quantitation proceeds via the classical external calibration procedure. It is shown that this novel data processing method allows one to apply not only parallel factor analysis (PARAFAC) and multivariate curve resolution-alternating least-squares (MCR-ALS), but also the recently introduced and more flexible partial least-squares (PLS) models coupled to residual bilinearization (RBL). In particular, the multidimensional variant N-PLS/RBL is shown to produce the best analytical results. The comparison is carried out with the aid of a set of simulated data, as well as two experimental data sets: one aimed at the determination of salicylate in human serum in the presence of naproxen as an additional interferent, and the second one devoted to the analysis of danofloxacin in human serum in the presence of salicylate.

  12. CPTAC Accelerates Precision Proteomics Biomedical Research | Office of Cancer Clinical Proteomics Research

    Cancer.gov

    The accurate quantitation of proteins or peptides using Mass Spectrometry (MS) is gaining prominence in the biomedical research community as an alternative method for analyte measurement. The Clinical Proteomic Tumor Analysis Consortium (CPTAC) investigators have been at the forefront in the promotion of reproducible MS techniques, through the development and application of standardized proteomic methods for protein quantitation on biologically relevant samples.

  13. Quantitative Method of Measuring Metastatic Activity

    NASA Technical Reports Server (NTRS)

    Morrison, Dennis R. (Inventor)

    1999-01-01

    The metastatic potential of tumors can be evaluated by the quantitative detection of urokinase and DNA. The cell sample selected for examination is analyzed for the presence of high levels of urokinase and abnormal DNA using analytical flow cytometry and digital image analysis. Other factors such as membrane associated uroldnase, increased DNA synthesis rates and certain receptors can be used in the method for detection of potentially invasive tumors.

  14. Distance-based microfluidic quantitative detection methods for point-of-care testing.

    PubMed

    Tian, Tian; Li, Jiuxing; Song, Yanling; Zhou, Leiji; Zhu, Zhi; Yang, Chaoyong James

    2016-04-07

    Equipment-free devices with quantitative readout are of great significance to point-of-care testing (POCT), which provides real-time readout to users and is especially important in low-resource settings. Among various equipment-free approaches, distance-based visual quantitative detection methods rely on reading the visual signal length for corresponding target concentrations, thus eliminating the need for sophisticated instruments. The distance-based methods are low-cost, user-friendly and can be integrated into portable analytical devices. Moreover, such methods enable quantitative detection of various targets by the naked eye. In this review, we first introduce the concept and history of distance-based visual quantitative detection methods. Then, we summarize the main methods for translation of molecular signals to distance-based readout and discuss different microfluidic platforms (glass, PDMS, paper and thread) in terms of applications in biomedical diagnostics, food safety monitoring, and environmental analysis. Finally, the potential and future perspectives are discussed.

  15. [Simultaneous quantitative analysis of five alkaloids in Sophora flavescens by multi-components assay by single marker].

    PubMed

    Chen, Jing; Wang, Shu-Mei; Meng, Jiang; Sun, Fei; Liang, Sheng-Wang

    2013-05-01

    To establish a new method for quality evaluation and validate its feasibilities by simultaneous quantitative assay of five alkaloids in Sophora flavescens. The new quality evaluation method, quantitative analysis of multi-components by single marker (QAMS), was established and validated with S. flavescens. Five main alkaloids, oxymatrine, sophocarpine, matrine, oxysophocarpine and sophoridine, were selected as analytes to evaluate the quality of rhizome of S. flavescens, and the relative correction factor has good repeatibility. Their contents in 21 batches of samples, collected from different areas, were determined by both external standard method and QAMS. The method was evaluated by comparison of the quantitative results between external standard method and QAMS. No significant differences were found in the quantitative results of five alkaloids in 21 batches of S. flavescens determined by external standard method and QAMS. It is feasible and suitable to evaluate the quality of rhizome of S. flavescens by QAMS.

  16. Chemical Sensor Array Response Modeling Using Quantitative Structure-Activity Relationships Technique

    NASA Astrophysics Data System (ADS)

    Shevade, Abhijit V.; Ryan, Margaret A.; Homer, Margie L.; Zhou, Hanying; Manfreda, Allison M.; Lara, Liana M.; Yen, Shiao-Pin S.; Jewell, April D.; Manatt, Kenneth S.; Kisor, Adam K.

    We have developed a Quantitative Structure-Activity Relationships (QSAR) based approach to correlate the response of chemical sensors in an array with molecular descriptors. A novel molecular descriptor set has been developed; this set combines descriptors of sensing film-analyte interactions, representing sensor response, with a basic analyte descriptor set commonly used in QSAR studies. The descriptors are obtained using a combination of molecular modeling tools and empirical and semi-empirical Quantitative Structure-Property Relationships (QSPR) methods. The sensors under investigation are polymer-carbon sensing films which have been exposed to analyte vapors at parts-per-million (ppm) concentrations; response is measured as change in film resistance. Statistically validated QSAR models have been developed using Genetic Function Approximations (GFA) for a sensor array for a given training data set. The applicability of the sensor response models has been tested by using it to predict the sensor activities for test analytes not considered in the training set for the model development. The validated QSAR sensor response models show good predictive ability. The QSAR approach is a promising computational tool for sensing materials evaluation and selection. It can also be used to predict response of an existing sensing film to new target analytes.

  17. N-nitrosamines as "special case" leachables in a metered dose inhaler drug product.

    PubMed

    Norwood, Daniel L; Mullis, James O; Feinberg, Thomas N; Davis, Letha K

    2009-01-01

    N-nitrosamines are chemical entities, some of which are considered to be possible human carcinogens, which can be found at trace levels in some types of foods, tobacco smoke, certain cosmetics, and certain types of rubber. N-nitrosamines are of regulatory concern as leachables in inhalation drug products, particularly metered dose inhalers, which incorporate rubber seals into their container closure systems. The United States Food and Drug Administration considers N-nitrosamines (along with polycyclic aromatic hydrocarbons and 2-mercaptobenzothiazole) to be "special case" leachables in inhalation drug products, meaning that there are no recognized safety or analytical thresholds and these compounds must therefore be identified and quantitated at the lowest practical level. This report presents the development of a quantitative analytical method for target volatile N-nitrosamines in a metered dose inhaler drug product, Atrovent HFA. The method incorporates a target analyte recovery procedure from the drug product matrix with analysis by gas chromatography/thermal energy analysis detection. The capability of the method was investigated with respect to specificity, linearity/range, accuracy (linearity of recovery), precision (repeatability, intermediate precision), limits of quantitation, standard/sample stability, and system suitability. Sample analyses showed that Atrovent HFA contains no target N-nitrosamines at the trace level of 1 ng/canister.

  18. Quantitation of promethazine and metabolites in urine samples using on-line solid-phase extraction and column-switching

    NASA Technical Reports Server (NTRS)

    Song, Q.; Putcha, L.; Harm, D. L. (Principal Investigator)

    2001-01-01

    A chromatographic method for the quantitation of promethazine (PMZ) and its three metabolites in urine employing on-line solid-phase extraction and column-switching has been developed. The column-switching system described here uses an extraction column for the purification of PMZ and its metabolites from a urine matrix. The extraneous matrix interference was removed by flushing the extraction column with a gradient elution. The analytes of interest were then eluted onto an analytical column for further chromatographic separation using a mobile phase of greater solvent strength. This method is specific and sensitive with a range of 3.75-1400 ng/ml for PMZ and 2.5-1400 ng/ml for the metabolites promethazine sulfoxide, monodesmethyl promethazine sulfoxide and monodesmethyl promethazine. The lower limits of quantitation (LLOQ) were 3.75 ng/ml with less than 6.2% C.V. for PMZ and 2.50 ng/ml with less than 11.5% C.V. for metabolites based on a signal-to-noise ratio of 10:1 or greater. The accuracy and precision were within +/- 11.8% in bias and not greater than 5.5% C.V. in intra- and inter-assay precision for PMZ and metabolites. Method robustness was investigated using a Plackett-Burman experimental design. The applicability of the analytical method for pharmacokinetic studies in humans is illustrated.

  19. Performance evaluation soil samples utilizing encapsulation technology

    DOEpatents

    Dahlgran, J.R.

    1999-08-17

    Performance evaluation soil samples and method of their preparation uses encapsulation technology to encapsulate analytes which are introduced into a soil matrix for analysis and evaluation by analytical laboratories. Target analytes are mixed in an appropriate solvent at predetermined concentrations. The mixture is emulsified in a solution of polymeric film forming material. The emulsified solution is polymerized to form microcapsules. The microcapsules are recovered, quantitated and introduced into a soil matrix in a predetermined ratio to form soil samples with the desired analyte concentration. 1 fig.

  20. Performance evaluation soil samples utilizing encapsulation technology

    DOEpatents

    Dahlgran, James R.

    1999-01-01

    Performance evaluation soil samples and method of their preparation using encapsulation technology to encapsulate analytes which are introduced into a soil matrix for analysis and evaluation by analytical laboratories. Target analytes are mixed in an appropriate solvent at predetermined concentrations. The mixture is emulsified in a solution of polymeric film forming material. The emulsified solution is polymerized to form microcapsules. The microcapsules are recovered, quantitated and introduced into a soil matrix in a predetermined ratio to form soil samples with the desired analyte concentration.

  1. Multi-Intelligence Analytics for Next Generation Analysts (MIAGA)

    NASA Astrophysics Data System (ADS)

    Blasch, Erik; Waltz, Ed

    2016-05-01

    Current analysts are inundated with large volumes of data from which extraction, exploitation, and indexing are required. A future need for next-generation analysts is an appropriate balance between machine analytics from raw data and the ability of the user to interact with information through automation. Many quantitative intelligence tools and techniques have been developed which are examined towards matching analyst opportunities with recent technical trends such as big data, access to information, and visualization. The concepts and techniques summarized are derived from discussions with real analysts, documented trends of technical developments, and methods to engage future analysts with multiintelligence services. For example, qualitative techniques should be matched against physical, cognitive, and contextual quantitative analytics for intelligence reporting. Future trends include enabling knowledge search, collaborative situational sharing, and agile support for empirical decision-making and analytical reasoning.

  2. Hierarchical Analytical Approaches for Unraveling the Composition of Proprietary Mixtures

    EPA Pesticide Factsheets

    The composition of commercial mixtures including pesticide inert ingredients, aircraft deicers, and aqueous film-forming foam (AFFF) formulations, and by analogy, fracking fluids, are proprietary. Quantitative analytical methodologies can only be developed for mixture components once their identities are known. Because proprietary mixtures may contain volatile and non-volatile components, a hierarchy of analytical methods is often required for the full identification of all proprietary mixture components.

  3. Evaluation methodology for comparing memory and communication of analytic processes in visual analytics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ragan, Eric D; Goodall, John R

    2014-01-01

    Provenance tools can help capture and represent the history of analytic processes. In addition to supporting analytic performance, provenance tools can be used to support memory of the process and communication of the steps to others. Objective evaluation methods are needed to evaluate how well provenance tools support analyst s memory and communication of analytic processes. In this paper, we present several methods for the evaluation of process memory, and we discuss the advantages and limitations of each. We discuss methods for determining a baseline process for comparison, and we describe various methods that can be used to elicit processmore » recall, step ordering, and time estimations. Additionally, we discuss methods for conducting quantitative and qualitative analyses of process memory. By organizing possible memory evaluation methods and providing a meta-analysis of the potential benefits and drawbacks of different approaches, this paper can inform study design and encourage objective evaluation of process memory and communication.« less

  4. Development and Validation of a Multiplexed Protein Quantitation Assay for the Determination of Three Recombinant Proteins in Soybean Tissues by Liquid Chromatography with Tandem Mass Spectrometry.

    PubMed

    Hill, Ryan C; Oman, Trent J; Shan, Guomin; Schafer, Barry; Eble, Julie; Chen, Cynthia

    2015-08-26

    Currently, traditional immunochemistry technologies such as enzyme-linked immunosorbent assays (ELISA) are the predominant analytical tool used to measure levels of recombinant proteins expressed in genetically engineered (GE) plants. Recent advances in agricultural biotechnology have created a need to develop methods capable of selectively detecting and quantifying multiple proteins in complex matrices because of increasing numbers of transgenic proteins being coexpressed or "stacked" to achieve tolerance to multiple herbicides or to provide multiple modes of action for insect control. A multiplexing analytical method utilizing liquid chromatography with tandem mass spectrometry (LC-MS/MS) has been developed and validated to quantify three herbicide-tolerant proteins in soybean tissues: aryloxyalkanoate dioxygenase (AAD-12), 5-enol-pyruvylshikimate-3-phosphate synthase (2mEPSPS), and phosphinothricin acetyltransferase (PAT). Results from the validation showed high recovery and precision over multiple analysts and laboratories. Results from this method were comparable to those obtained with ELISA with respect to protein quantitation, and the described method was demonstrated to be suitable for multiplex quantitation of transgenic proteins in GE crops.

  5. Method 1200: Analytical Protocol for Non-Typhoidal Salmonella in Drinking Water and Surface Water

    EPA Pesticide Factsheets

    Method 1200 is used for identification, confirmation and quantitation of non-typhoidal Salmonella in water samples, using selective and non-selective media followed by biochemical and serological confirmation.

  6. Sieve-based device for MALDI sample preparation. III. Its power for quantitative measurements.

    PubMed

    Molin, Laura; Cristoni, Simone; Seraglia, Roberta; Traldi, Pietro

    2011-02-01

    The solid sample inhomogeneity is a weak point of traditional MALDI deposition techniques that reflects negatively on quantitative analysis. The recently developed sieve-based device (SBD) sample deposition method, based on the electrospraying of matrix/analyte solutions through a grounded sieve, allows the homogeneous deposition of microcrystals with dimensions smaller than that of the laser spot. In each microcrystal the matrix/analyte molar ratio can be considered constant. Then, by irradiating different portions of the microcrystal distribution an identical response is obtained. This result suggests the employment of SBD in the development of quantitative procedures. For this aim, mixtures of different proteins of known molarity were analyzed, showing a good relationship between molarity and intensity ratios. This behaviour was also observed in the case of proteins with quite different ionic yields. The power of the developed method for quantitative evaluation was also tested by the measurement of the abundance of IGPP[Oxi]GPP[Oxi]GLMGPP (m/z 1219) present in the collagen-α-5(IV) chain precursor, differently expressed in urines from healthy subjects and diabetic-nephropathic patients, confirming its overexpression in the presence of nephropathy. The data obtained indicate that SBD is a particularly effective method for quantitative analysis also in biological fluids of interest. Copyright © 2011 John Wiley & Sons, Ltd.

  7. Quantitative Literacy for Undergraduate Business Students in the 21st Century

    ERIC Educational Resources Information Center

    McClure, Richard; Sircar, Sumit

    2008-01-01

    The current business environment is awash in vast amounts of data that ongoing transactions continually generate. Leading-edge corporations are using business analytics to achieve competitive advantage. However, educators are not adequately preparing business school students in quantitative methods to meet this challenge. For more than half a…

  8. 21 CFR 570.35 - Affirmation of generally recognized as safe (GRAS) status.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... to the NAS-NRC GRAS list survey (36 FR 20546), shall submit a petition for GRAS affirmation pursuant... included where applicable.) (g) Quantitative compositions. (h) Manufacturing process (excluding any trade... quantitative methods for determining the substance(s) in food, including the type of analytical procedures used...

  9. 21 CFR 570.35 - Affirmation of generally recognized as safe (GRAS) status.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... to the NAS-NRC GRAS list survey (36 FR 20546), shall submit a petition for GRAS affirmation pursuant... included where applicable.) (g) Quantitative compositions. (h) Manufacturing process (excluding any trade... quantitative methods for determining the substance(s) in food, including the type of analytical procedures used...

  10. 21 CFR 570.35 - Affirmation of generally recognized as safe (GRAS) status.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... to the NAS-NRC GRAS list survey (36 FR 20546), shall submit a petition for GRAS affirmation pursuant... included where applicable.) (g) Quantitative compositions. (h) Manufacturing process (excluding any trade... quantitative methods for determining the substance(s) in food, including the type of analytical procedures used...

  11. 21 CFR 570.35 - Affirmation of generally recognized as safe (GRAS) status.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... to the NAS-NRC GRAS list survey (36 FR 20546), shall submit a petition for GRAS affirmation pursuant... included where applicable.) (g) Quantitative compositions. (h) Manufacturing process (excluding any trade... quantitative methods for determining the substance(s) in food, including the type of analytical procedures used...

  12. 21 CFR 570.35 - Affirmation of generally recognized as safe (GRAS) status.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... to the NAS-NRC GRAS list survey (36 FR 20546), shall submit a petition for GRAS affirmation pursuant... included where applicable.) (g) Quantitative compositions. (h) Manufacturing process (excluding any trade... quantitative methods for determining the substance(s) in food, including the type of analytical procedures used...

  13. Liquid chromatographic determination of benzocaine and N-acetylbenzocaine in the edible fillet tissue from rainbow trout

    USGS Publications Warehouse

    Meinertz, J.R.; Stehly, G.R.; Hubert, T.D.; Bernardy, J.A.

    1999-01-01

    A method was developed for determining benzocaine and N-acetylbenzocaine concentrations in fillet tissue of rainbow trout. The method involves extracting the analytes with acetonitrile, removing lipids or hydrophobic compounds from the extract with hexane, and providing additional clean-up with solid-phase extraction techniques. Analyte concentrations are determined using reversed-phase high-performance liquid chromatographic techniques with an isocratic mobile phase and UV detection. The accuracy (range, 92 to 121%), precision (R.S.D., <14%), and sensitivity (method quantitation limit, <24 ng/g) for each analyte indicate the usefulness of this method for studies characterizing the depletion of benzocaine residues from fish exposed to benzocaine. Copyright (C) 1999.

  14. Fast analytical spectral filtering methods for magnetic resonance perfusion quantification.

    PubMed

    Reddy, Kasireddy V; Mitra, Abhishek; Yalavarthy, Phaneendra K

    2016-08-01

    The deconvolution in the perfusion weighted imaging (PWI) plays an important role in quantifying the MR perfusion parameters. The PWI application to stroke and brain tumor studies has become a standard clinical practice. The standard approach for this deconvolution is oscillatory-limited singular value decomposition (oSVD) and frequency domain deconvolution (FDD). The FDD is widely recognized as the fastest approach currently available for deconvolution of MR perfusion data. In this work, two fast deconvolution methods (namely analytical fourier filtering and analytical showalter spectral filtering) are proposed. Through systematic evaluation, the proposed methods are shown to be computationally efficient and quantitatively accurate compared to FDD and oSVD.

  15. Development of a GC/MS method for the qualitative and quantitative analysis of mixtures of free fatty acids and metal soaps in paint samples.

    PubMed

    La Nasa, Jacopo; Modugno, Francesca; Aloisi, Matteo; Lluveras-Tenorio, Anna; Bonaduce, Ilaria

    2018-02-25

    In this paper we present a new analytical GC/MS method for the analysis of mixtures of free fatty acids and metal soaps in paint samples. This approach is based on the use of two different silylating agents: N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) and 1,1,1,3,3,3-hexamethyldisilazane (HMDS). Our experimentation demonstrated that HMDS does not silylate fatty acid carboxylates, so it can be used for the selective derivatization and GC/MS quantitative analysis of free fatty acids. On the other hand BSTFA is able to silylate both free fatty acids and fatty acids carboxylates. The reaction conditions for the derivatization of carboxylates with BSTFA were thus optimized with a full factorial 3 2 experimental design using lead stearate and lead palmitate as model systems. The analytical method was validated following the ICH guidelines. The method allows the qualitative and quantitative analysis of fatty acid carboxylates of sodium, calcium, magnesium, aluminium, manganese, cobalt, copper, zinc, cadmium, and lead and of lead azelate. In order to exploit the performances of the new analytical method, samples collected from two reference paint layers, from a gilded 16th century marble sculpture, and from a paint tube belonging to the atelier of Edvard Munch, used in the last period of his life (1916-1944), were characterized. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Quantitative evaluation of the matrix effect in bioanalytical methods based on LC-MS: A comparison of two approaches.

    PubMed

    Rudzki, Piotr J; Gniazdowska, Elżbieta; Buś-Kwaśnik, Katarzyna

    2018-06-05

    Liquid chromatography coupled to mass spectrometry (LC-MS) is a powerful tool for studying pharmacokinetics and toxicokinetics. Reliable bioanalysis requires the characterization of the matrix effect, i.e. influence of the endogenous or exogenous compounds on the analyte signal intensity. We have compared two methods for the quantitation of matrix effect. The CVs(%) of internal standard normalized matrix factors recommended by the European Medicines Agency were evaluated against internal standard normalized relative matrix effects derived from Matuszewski et al. (2003). Both methods use post-extraction spiked samples, but matrix factors require also neat solutions. We have tested both approaches using analytes of diverse chemical structures. The study did not reveal relevant differences in the results obtained with both calculation methods. After normalization with the internal standard, the CV(%) of the matrix factor was on average 0.5% higher than the corresponding relative matrix effect. The method adopted by the European Medicines Agency seems to be slightly more conservative in the analyzed datasets. Nine analytes of different structures enabled a general overview of the problem, still, further studies are encouraged to confirm our observations. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Quantitative analysis of sitagliptin using the (19)F-NMR method: a universal technique for fluorinated compound detection.

    PubMed

    Zhang, Fen-Fen; Jiang, Meng-Hong; Sun, Lin-Lin; Zheng, Feng; Dong, Lei; Shah, Vishva; Shen, Wen-Bin; Ding, Ya

    2015-01-07

    To expand the application scope of nuclear magnetic resonance (NMR) technology in quantitative analysis of pharmaceutical ingredients, (19)F nuclear magnetic resonance ((19)F-NMR) spectroscopy has been employed as a simple, rapid, and reproducible approach for the detection of a fluorine-containing model drug, sitagliptin phosphate monohydrate (STG). ciprofloxacin (Cipro) has been used as the internal standard (IS). Influential factors, including the relaxation delay time (d1) and pulse angle, impacting the accuracy and precision of spectral data are systematically optimized. Method validation has been carried out in terms of precision and intermediate precision, linearity, limit of detection (LOD) and limit of quantification (LOQ), robustness, and stability. To validate the reliability and feasibility of the (19)F-NMR technology in quantitative analysis of pharmaceutical analytes, the assay result has been compared with that of (1)H-NMR. The statistical F-test and student t-test at 95% confidence level indicate that there is no significant difference between these two methods. Due to the advantages of (19)F-NMR, such as higher resolution and suitability for biological samples, it can be used as a universal technology for the quantitative analysis of other fluorine-containing pharmaceuticals and analytes.

  18. Chemoenzymatic method for glycomics: isolation, identification, and quantitation

    PubMed Central

    Yang, Shuang; Rubin, Abigail; Eshghi, Shadi Toghi; Zhang, Hui

    2015-01-01

    Over the past decade, considerable progress has been made with respect to the analytical methods for analysis of glycans from biological sources. Regardless of the specific methods that are used, glycan analysis includes isolation, identification, and quantitation. Derivatization is indispensable to increase their identification. Derivatization of glycans can be performed by permethylation or carbodiimide coupling / esterification. By introducing a fluorophore or chromophore at their reducing end, glycans can be separated by electrophoresis or chromatography. The fluorogenically labeled glycans can be quantitated using fluorescent detection. The recently developed approaches using solid-phase such as glycoprotein immobilization for glycan extraction and on-tissue glycan mass spectrometry imaging demonstrate advantages over methods performed in solution. Derivatization of sialic acids is favorably implemented on the solid support using carbodiimide coupling, and the released glycans can be further modified at the reducing end or permethylated for quantitative analysis. In this review, methods for glycan isolation, identification, and quantitation are discussed. PMID:26390280

  19. Quantitative method of measuring cancer cell urokinase and metastatic potential

    NASA Technical Reports Server (NTRS)

    Morrison, Dennis R. (Inventor)

    1993-01-01

    The metastatic potential of tumors can be evaluated by the quantitative detection of urokinase and DNA. The cell sample selected for examination is analyzed for the presence of high levels of urokinase and abnormal DNA using analytical flow cytometry and digital image analysis. Other factors such as membrane associated urokinase, increased DNA synthesis rates and certain receptors can be used in the method for detection of potentially invasive tumors.

  20. Development of an Analytical Method for the Determination of Amoxicillin in Commercial Drugs and Wastewater Samples, and Assessing its Stability in Simulated Gastric Digestion.

    PubMed

    Unutkan, Tugçe; Bakirdere, Sezgin; Keyf, Seyfullah

    2018-01-01

    A highly sensitive analytical HPLC-UV method was developed for the determination of amoxicillin in drugs and wastewater samples at a single wavelength (230 nm). In order to substantially predict the in vivo behavior of amoxicillin, drug samples were subjected to simulated gastric conditions. The calibration plot of the method was linear from 0.050 to 500 mg L-1 with a correlation coefficient of 0.9999. The limit of detection and limit of quantitation were found to be 16 and 54 μg L-1, respectively. The percentage recovery of amoxicillin in wastewater was found to be 97.0 ± 1.6%. The method was successfully applied for the qualitative and quantitative determination of amoxicillin in drug samples including tablets and suspensions. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Supersymmetric quantum mechanics method for the Fokker-Planck equation with applications to protein folding dynamics

    NASA Astrophysics Data System (ADS)

    Polotto, Franciele; Drigo Filho, Elso; Chahine, Jorge; Oliveira, Ronaldo Junio de

    2018-03-01

    This work developed analytical methods to explore the kinetics of the time-dependent probability distributions over thermodynamic free energy profiles of protein folding and compared the results with simulation. The Fokker-Planck equation is mapped onto a Schrödinger-type equation due to the well-known solutions of the latter. Through a semi-analytical description, the supersymmetric quantum mechanics formalism is invoked and the time-dependent probability distributions are obtained with numerical calculations by using the variational method. A coarse-grained structure-based model of the two-state protein Tm CSP was simulated at a Cα level of resolution and the thermodynamics and kinetics were fully characterized. Analytical solutions from non-equilibrium conditions were obtained with the simulated double-well free energy potential and kinetic folding times were calculated. It was found that analytical folding time as a function of temperature agrees, quantitatively, with simulations and experiments from the literature of Tm CSP having the well-known 'U' shape of the Chevron Plots. The simple analytical model developed in this study has a potential to be used by theoreticians and experimentalists willing to explore, quantitatively, rates and the kinetic behavior of their system by informing the thermally activated barrier. The theory developed describes a stochastic process and, therefore, can be applied to a variety of biological as well as condensed-phase two-state systems.

  2. Comparative Evaluation of Four Real-Time PCR Methods for the Quantitative Detection of Epstein-Barr Virus from Whole Blood Specimens.

    PubMed

    Buelow, Daelynn; Sun, Yilun; Tang, Li; Gu, Zhengming; Pounds, Stanley; Hayden, Randall

    2016-07-01

    Monitoring of Epstein-Barr virus (EBV) load in immunocompromised patients has become integral to their care. An increasing number of reagents are available for quantitative detection of EBV; however, there are little published comparative data. Four real-time PCR systems (one using laboratory-developed reagents and three using analyte-specific reagents) were compared with one another for detection of EBV from whole blood. Whole blood specimens seeded with EBV were used to determine quantitative linearity, analytical measurement range, lower limit of detection, and CV for each assay. Retrospective testing of 198 clinical samples was performed in parallel with all methods; results were compared to determine relative quantitative and qualitative performance. All assays showed similar performance. No significant difference was found in limit of detection (3.12-3.49 log10 copies/mL; P = 0.37). A strong qualitative correlation was seen with all assays that used clinical samples (positive detection rates of 89.5%-95.8%). Quantitative correlation of clinical samples across assays was also seen in pairwise regression analysis, with R(2) ranging from 0.83 to 0.95. Normalizing clinical sample results to IU/mL did not alter the quantitative correlation between assays. Quantitative EBV detection by real-time PCR can be performed over a wide linear dynamic range, using three different commercially available reagents and laboratory-developed methods. EBV was detected with comparable sensitivity and quantitative correlation for all assays. Copyright © 2016 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  3. A technique for setting analytical thresholds in massively parallel sequencing-based forensic DNA analysis

    PubMed Central

    2017-01-01

    Amplicon (targeted) sequencing by massively parallel sequencing (PCR-MPS) is a potential method for use in forensic DNA analyses. In this application, PCR-MPS may supplement or replace other instrumental analysis methods such as capillary electrophoresis and Sanger sequencing for STR and mitochondrial DNA typing, respectively. PCR-MPS also may enable the expansion of forensic DNA analysis methods to include new marker systems such as single nucleotide polymorphisms (SNPs) and insertion/deletions (indels) that currently are assayable using various instrumental analysis methods including microarray and quantitative PCR. Acceptance of PCR-MPS as a forensic method will depend in part upon developing protocols and criteria that define the limitations of a method, including a defensible analytical threshold or method detection limit. This paper describes an approach to establish objective analytical thresholds suitable for multiplexed PCR-MPS methods. A definition is proposed for PCR-MPS method background noise, and an analytical threshold based on background noise is described. PMID:28542338

  4. A technique for setting analytical thresholds in massively parallel sequencing-based forensic DNA analysis.

    PubMed

    Young, Brian; King, Jonathan L; Budowle, Bruce; Armogida, Luigi

    2017-01-01

    Amplicon (targeted) sequencing by massively parallel sequencing (PCR-MPS) is a potential method for use in forensic DNA analyses. In this application, PCR-MPS may supplement or replace other instrumental analysis methods such as capillary electrophoresis and Sanger sequencing for STR and mitochondrial DNA typing, respectively. PCR-MPS also may enable the expansion of forensic DNA analysis methods to include new marker systems such as single nucleotide polymorphisms (SNPs) and insertion/deletions (indels) that currently are assayable using various instrumental analysis methods including microarray and quantitative PCR. Acceptance of PCR-MPS as a forensic method will depend in part upon developing protocols and criteria that define the limitations of a method, including a defensible analytical threshold or method detection limit. This paper describes an approach to establish objective analytical thresholds suitable for multiplexed PCR-MPS methods. A definition is proposed for PCR-MPS method background noise, and an analytical threshold based on background noise is described.

  5. Creating analytically divergence-free velocity fields from grid-based data

    NASA Astrophysics Data System (ADS)

    Ravu, Bharath; Rudman, Murray; Metcalfe, Guy; Lester, Daniel R.; Khakhar, Devang V.

    2016-10-01

    We present a method, based on B-splines, to calculate a C2 continuous analytic vector potential from discrete 3D velocity data on a regular grid. A continuous analytically divergence-free velocity field can then be obtained from the curl of the potential. This field can be used to robustly and accurately integrate particle trajectories in incompressible flow fields. Based on the method of Finn and Chacon (2005) [10] this new method ensures that the analytic velocity field matches the grid values almost everywhere, with errors that are two to four orders of magnitude lower than those of existing methods. We demonstrate its application to three different problems (each in a different coordinate system) and provide details of the specifics required in each case. We show how the additional accuracy of the method results in qualitatively and quantitatively superior trajectories that results in more accurate identification of Lagrangian coherent structures.

  6. A rapid quantitative determination of phenolic acids in Brassica oleracea by capillary zone electrophoresis.

    PubMed

    Lee, Iris S L; Boyce, Mary C; Breadmore, Michael C

    2011-07-15

    A simple and rapid capillary zone electrophoresis method to quantitatively determine the phenolic acid contents in brassica vegetables is described. Phenolic compounds were extracted from broccoli, broccolini, Brussels sprouts, cabbage and cauliflower and the main hydroxycinnamic acids (sinapic, ferulic, p-coumaric and caffeic acids) were isolated by solid phase extraction with C18 cartridges. Using an optimised method, the four analytes were separated in less than 7min in a 50μm×60cm capillary with a 15mM borate buffer (pH=9.13) and a separation voltage of 30kV at 30°C. A linear relationship was observed for the method (r=0.9997-0.9999) with detection limits ranging from 1.1 to 2.3mg/kg of vegetables for the analytes. This method demonstrated good reproducibility with coefficients of variation of less than 5% for peak area and less than 1% for migration time (n=7). The method was successfully applied to quantitatively determine the phenolic acid contents in a range of brassica vegetables and the results were in good agreement when compared to those from high performance liquid chromatography analysis. Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.

  7. Quantitative Determination of Caffeine in Beverages Using a Combined SPME-GC/MS Method

    NASA Astrophysics Data System (ADS)

    Pawliszyn, Janusz; Yang, Min J.; Orton, Maureen L.

    1997-09-01

    Solid-phase microextraction (SPME) combined with gas chromatography/mass spectrometry (GC/MS) has been applied to the analysis of various caffeinated beverages. Unlike the current methods, this technique is solvent free and requires no pH adjustments. The simplicity of the SPME-GC/MS method lends itself to a good undergraduate laboratory practice. This publication describes the analytical conditions and presents the data for determination of caffeine in coffee, tea, and coke. Quantitation by isotopic dilution is also illustrated.

  8. Pushing quantitation limits in micro UHPLC-MS/MS analysis of steroid hormones by sample dilution using high volume injection.

    PubMed

    Márta, Zoltán; Bobály, Balázs; Fekete, Jenő; Magda, Balázs; Imre, Tímea; Mészáros, Katalin Viola; Szabó, Pál Tamás

    2016-09-10

    Ultratrace analysis of sample components requires excellent analytical performance in terms of limits of quantitation (LoQ). Micro UHPLC coupling with sensitive tandem mass spectrometry provides state of the art solutions for such analytical problems. Decreased column volume in micro LC limits the injectable sample volume. However, if analyte concentration is extremely low, it might be necessary to inject high sample volumes. This is particularly critical for strong sample solvents and weakly retained analytes, which are often the case when preparing biological samples (protein precipitation, sample extraction, etc.). In that case, high injection volumes may cause band broadening, peak distortion or even elution in dead volume. In this study, we evaluated possibilities of high volume injection onto microbore RP-LC columns, when sample solvent is diluted. The presented micro RP-LC-MS/MS method was optimized for the analysis of steroid hormones from human plasma after protein precipitation with organic solvents. A proper sample dilution procedure helps to increase the injection volume without compromising peak shapes. Finally, due to increased injection volume, the limit of quantitation can be decreased by a factor of 2-5, depending on the analytes and the experimental conditions. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Trace analysis of trimethoprim and sulfonamide, macrolide, quinolone, and tetracycline antibiotics in chlorinated drinking water using liquid chromatography electrospray tandem mass spectrometry

    USGS Publications Warehouse

    Ye, Z.; Weinberg, H.S.; Meyer, M.T.

    2007-01-01

    A multirun analytical method has been developed and validated for trace determination of 24 antibiotics including 7 sulfonamides, 3 macrolides, 7 quinolones, 6 tetracyclines, and trimethoprim in chlorine-disinfected drinking water using a single solid-phase extraction method coupled to liquid chromatography with positive electrospray tandem mass spectrometry detection. The analytes were extracted by a hydrophilic-lipophilic balanced resin and eluted with acidified methanol (0.1% formic acid), resulting in analyte recoveries generally above 90%. The limits of quantitation were mostly below 10 ng/L in drinking water. Since the concentrated sample matrix typically caused ion suppression during electrospray ionization, the method of standard addition was used for quantitation. Chlorine residuals in drinking water can react with some antibiotics, but ascorbic acid was found to be an effective chlorine quenching agent without affecting the analysis and stability of the antibiotics in water. A preliminary occurrence study using this method revealed the presence of some antibiotics in drinking waters, including sulfamethoxazole (3.0-3.4 ng/L), macrolides (1.4-4.9 ng/L), and quinolones (1.2-4.0 ng/L). ?? 2007 American Chemical Society.

  10. Detection of biological molecules using chemical amplification and optical sensors

    DOEpatents

    Van Antwerp, William Peter; Mastrototaro, John Joseph

    2000-01-01

    Methods are provided for the determination of the concentration of biological levels of polyhydroxylated compounds, particularly glucose. The methods utilize an amplification system that is an analyte transducer immobilized in a polymeric matrix, where the system is implantable and biocompatible. Upon interrogation by an optical system, the amplification system produces a signal capable of detection external to the skin of the patient. Quantitation of the analyte of interest is achieved by measurement of the emitted signal.

  11. Detection of biological molecules using chemical amplification and optical sensors

    DOEpatents

    Van Antwerp, William Peter; Mastrototaro, John Joseph

    2004-10-12

    Methods are provided for the determination of the concentration of biological levels of polyhydroxylated compounds, particularly glucose. The methods utilize an amplification system that is an analyte transducer immobilized in a polymeric matrix, where the system is implantable and biocompatible. Upon interrogation by an optical system, the amplification system produces a signal capable of detection external to the skin of the patient. Quantitation of the analyte of interest is achieved by measurement of the emitted signal.

  12. Simultaneous determination of niacin and pyridoxine at trace levels by using diode array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry.

    PubMed

    Sel, Sabriye; Öztürk Er, Elif; Bakırdere, Sezgin

    2017-12-01

    A highly sensitive and simple diode-array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry method was developed for the simultaneous determination of niacin and pyridoxine in pharmaceutical drugs, tap water, and wastewater samples. To determine the in vivo behavior of niacin and pyridoxine, analytes were subjected to simulated gastric conditions. The calibration plots of the diode-array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry method showed good linearity over a wide concentration range with close to 1.0 correlation coefficients for both analytes. The limit of detection/limit of quantitation values for liquid chromatography quadrupole time-of-flight tandem mass spectrometry analysis were 1.98/6.59 and 1.3/4.4 μg/L for niacin and pyridoxine, respectively, while limit of detection/limit of quantitation values for niacin and pyridoxine in high-performance liquid chromatography analysis were 3.7/12.3 and 5.7/18.9 μg/L, respectively. Recovery studies were also performed to show the applicability of the developed methods, and percentage recovery values were found to be 90-105% in tap water and 94-97% in wastewater for both analytes. The method was also successfully applied for the qualitative and quantitative determination of niacin and pyridoxine in drug samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Quantitative determination of metformin, glyburide and its metabolites in plasma and urine of pregnant patients by LC-MS/MS.

    PubMed

    Zhang, Xing; Wang, Xiaoming; Vernikovskaya, Daria I; Fokina, Valentina M; Nanovskaya, Tatiana N; Hankins, Gary D V; Ahmed, Mahmoud S

    2015-04-01

    This report describes the development and validation of an LC-MS/MS method for the quantitative determination of glyburide (GLB), its five metabolites (M1, M2a, M2b, M3 and M4) and metformin (MET) in plasma and urine of pregnant patients under treatment with a combination of the two medications. The extraction recovery of the analytes from plasma samples was 87-99%, and that from urine samples was 85-95%. The differences in retention times among the analytes and the wide range of the concentrations of the medications and their metabolites in plasma and urine patient samples required the development of three LC methods. The lower limit of quantitation (LLOQ) of the analytes in plasma samples was as follows: GLB, 1.02 ng/mL; its five metabolites, 0.100-0.113 ng/mL; and MET, 4.95 ng/mL. The LLOQ in urine samples was 0.0594 ng/mL for GLB, 0.984-1.02 ng/mL for its five metabolites and 30.0 µg/mL for MET. The relative deviation of this method was <14% for intra-day and inter-day assays in plasma and urine samples, and the accuracy was 86-114% in plasma, and 94-105% in urine. The method described in this report was successfully utilized for determining the concentrations of the two medications in patient plasma and urine. Copyright © 2014 John Wiley & Sons, Ltd.

  14. Quantitative determination of metformin, glyburide and its metabolites in plasma and urine of pregnant patients by LC-MS/MS

    PubMed Central

    Zhang, Xing; Wang, Xiaoming; Vernikovskaya, Daria I.; Fokina, Valentina M.; Nanovskaya, Tatiana N.; Hankins, Gary D.V.; Ahmed, Mahmoud S.

    2014-01-01

    This report describes the development and validation of an LC-MS/MS method for the quantitative determination of glyburide (GLB), its five metabolites (M1, M2a, M2b, M3, and M4) and metformin (MET) in plasma and urine of pregnant patients under treatment with a combination of the two medications. The extraction recovery of the analytes from plasma samples ranged between 87% and 99%, and 85%–95% for urine samples. The differences in retention times among the analytes, and the wide range of the concentrations of the medications and their metabolites in plasma and urine patient samples required the development of three LC methods. The lower limit of quantitation (LLOQ) of the analytes in plasma samples was as follows: GLB, 1.02 ng/mL; its five metabolites, 0.100–0.113 ng/mL and 4.95 ng/mL for MET. LLOQ in urine samples was 0.0594 ng/mL for GLB, 0.984–1.02 ng/mL for its five metabolites and 30.0 μg/mL for MET. The relative deviation of this method was < 14% for intra-day and inter-day assays in plasma and urine samples, and the accuracy ranged between 86% and 114% in plasma, and 94% to 105% in urine. The method described in this report was successfully utilized for determining the concentrations of the two medications in patient plasma and urine. PMID:25164921

  15. Development of a comprehensive analytical platform for the detection and quantitation of food fraud using a biomarker approach. The oregano adulteration case study.

    PubMed

    Wielogorska, Ewa; Chevallier, Olivier; Black, Connor; Galvin-King, Pamela; Delêtre, Marc; Kelleher, Colin T; Haughey, Simon A; Elliott, Christopher T

    2018-01-15

    Due to increasing number of food fraud incidents, there is an inherent need for the development and implementation of analytical platforms enabling detection and quantitation of adulteration. In this study a set of unique biomarkers of commonly found oregano adulterants became the targets in the development of a LC-MS/MS method which underwent a rigorous in-house validation. The method presented very high selectivity and specificity, excellent linearity (R 2 >0.988) low decision limits and detection capabilities (<2%), acceptable accuracy (intra-assay 92-113%, inter-assay 69-138%) and precision (CV<20%). The method was compared with an established FTIR screening assay and revealed a good correlation of quali- and quantitative results (R 2 >0.81). An assessment of 54 suspected adulterated oregano samples revealed that almost 90% of them contained at least one bulking agent, with a median level of adulteration of 50%. Such innovative methodologies need to be established as routine testing procedures to detect and ultimately deter food fraud. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. A novel approach for quantitation of nonderivatized sialic acid in protein therapeutics using hydrophilic interaction chromatographic separation and nano quantity analyte detection.

    PubMed

    Chemmalil, Letha; Suravajjala, Sreekanth; See, Kate; Jordan, Eric; Furtado, Marsha; Sun, Chong; Hosselet, Stephen

    2015-01-01

    This paper describes a novel approach for the quantitation of nonderivatized sialic acid in glycoproteins, separated by hydrophilic interaction chromatography, and detection by Nano Quantity Analyte Detector (NQAD). The detection technique of NQAD is based on measuring change in the size of dry aerosol and converting the particle count rate into chromatographic output signal. NQAD detector is suitable for the detection of sialic acid, which lacks sufficiently active chromophore or fluorophore. The water condensation particle counting technology allows the analyte to be enlarged using water vapor to provide highest sensitivity. Derivatization-free analysis of glycoproteins using HPLC/NQAD method with PolyGLYCOPLEX™ amide column is well correlated with HPLC method with precolumn derivatization using 1, 2-diamino-4, 5-methylenedioxybenzene (DMB) as well as the Dionex-based high-pH anion-exchange chromatography (or ion chromatography) with pulsed amperometric detection (HPAEC-PAD). With the elimination of derivatization step, HPLC/NQAD method is more efficient than HPLC/DMB method. HPLC/NQAD method is more reproducible than HPAEC-PAD method as HPAEC-PAD method suffers high variability because of electrode fouling during analysis. Overall, HPLC/NQAD method offers broad linear dynamic range as well as excellent precision, accuracy, repeatability, reliability, and ease of use, with acceptable comparability to the commonly used HPAEC-PAD and HPLC/DMB methods. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.

  17. The Water-Energy-Food Nexus: Advancing Innovative, Policy-Relevant Methods

    NASA Astrophysics Data System (ADS)

    Crootof, A.; Albrecht, T.; Scott, C. A.

    2017-12-01

    The water-energy-food (WEF) nexus is rapidly expanding in scholarly literature and policy settings as a novel way to address complex Anthropocene challenges. The nexus approach aims to identify tradeoffs and synergies of water, energy, and food systems, internalize social and environmental impacts, and guide development of cross-sectoral policies. However, a primary limitation of the nexus approach is the absence - or gaps and inconsistent use - of adequate methods to advance an innovative and policy-relevant nexus approach. This paper presents an analytical framework to identify robust nexus methods that align with nexus thinking and highlights innovative nexus methods at the frontier. The current state of nexus methods was assessed with a systematic review of 245 journal articles and book chapters. This review revealed (a) use of specific and reproducible methods for nexus assessment is uncommon - less than one-third of the reviewed studies present explicit methods; (b) nexus methods frequently fall short of capturing interactions among water, energy, and food - the very concept they purport to address; (c) assessments strongly favor quantitative approaches - 70% use primarily quantitative tools; (d) use of social science methods is limited (26%); and (e) many nexus methods are confined to disciplinary silos - only about one-quarter combine methods from diverse disciplines and less than one-fifth utilize both quantitative and qualitative approaches. Despite some pitfalls of current nexus methods, there are a host of studies that offer innovative approaches to help quantify nexus linkages and interactions among sectors, conceptualize dynamic feedbacks, and support mixed method approaches to better understand WEF systems. Applying our analytical framework to all 245 studies, we identify, and analyze herein, seventeen studies that implement innovative multi-method and cross-scalar tools to demonstrate promising advances toward improved nexus assessment. This paper finds that, to make the WEF nexus effective as a policy-relevant analytical tool, methods are needed that incorporate social and political dimensions of water, energy, and food; utilize multiple and interdisciplinary approaches; and engage stakeholders and policy-makers.

  18. The NIST Quantitative Infrared Database

    PubMed Central

    Chu, P. M.; Guenther, F. R.; Rhoderick, G. C.; Lafferty, W. J.

    1999-01-01

    With the recent developments in Fourier transform infrared (FTIR) spectrometers it is becoming more feasible to place these instruments in field environments. As a result, there has been enormous increase in the use of FTIR techniques for a variety of qualitative and quantitative chemical measurements. These methods offer the possibility of fully automated real-time quantitation of many analytes; therefore FTIR has great potential as an analytical tool. Recently, the U.S. Environmental Protection Agency (U.S.EPA) has developed protocol methods for emissions monitoring using both extractive and open-path FTIR measurements. Depending upon the analyte, the experimental conditions and the analyte matrix, approximately 100 of the hazardous air pollutants (HAPs) listed in the 1990 U.S.EPA Clean Air Act amendment (CAAA) can be measured. The National Institute of Standards and Technology (NIST) has initiated a program to provide quality-assured infrared absorption coefficient data based on NIST prepared primary gas standards. Currently, absorption coefficient data has been acquired for approximately 20 of the HAPs. For each compound, the absorption coefficient spectrum was calculated using nine transmittance spectra at 0.12 cm−1 resolution and the Beer’s law relationship. The uncertainties in the absorption coefficient data were estimated from the linear regressions of the transmittance data and considerations of other error sources such as the nonlinear detector response. For absorption coefficient values greater than 1 × 10−4 μmol/mol)−1 m−1 the average relative expanded uncertainty is 2.2 %. This quantitative infrared database is currently an ongoing project at NIST. Additional spectra will be added to the database as they are acquired. Our current plans include continued data acquisition of the compounds listed in the CAAA, as well as the compounds that contribute to global warming and ozone depletion.

  19. Quantitation by Portable Gas Chromatography: Mass Spectrometry of VOCs Associated with Vapor Intrusion

    PubMed Central

    Fair, Justin D.; Bailey, William F.; Felty, Robert A.; Gifford, Amy E.; Shultes, Benjamin; Volles, Leslie H.

    2010-01-01

    Development of a robust reliable technique that permits for the rapid quantitation of volatile organic chemicals is an important first step to remediation associated with vapor intrusion. This paper describes the development of an analytical method that allows for the rapid and precise identification and quantitation of halogenated and nonhalogenated contaminants commonly found within the ppbv level at sites where vapor intrusion is a concern. PMID:20885969

  20. Ultrafast quantitation of six quinolones in water samples by second-order capillary electrophoresis data modeling with multivariate curve resolution-alternating least squares.

    PubMed

    Alcaráz, Mirta R; Vera-Candioti, Luciana; Culzoni, María J; Goicoechea, Héctor C

    2014-04-01

    This paper presents the development of a capillary electrophoresis method with diode array detector coupled to multivariate curve resolution-alternating least squares (MCR-ALS) to conduct the resolution and quantitation of a mixture of six quinolones in the presence of several unexpected components. Overlapping of time profiles between analytes and water matrix interferences were mathematically solved by data modeling with the well-known MCR-ALS algorithm. With the aim of overcoming the drawback originated by two compounds with similar spectra, a special strategy was implemented to model the complete electropherogram instead of dividing the data in the region as usually performed in previous works. The method was first applied to quantitate analytes in standard mixtures which were randomly prepared in ultrapure water. Then, tap water samples spiked with several interferences were analyzed. Recoveries between 76.7 and 125 % and limits of detection between 5 and 18 μg L(-1) were achieved.

  1. Apparatus for rapid measurement of aerosol bulk chemical composition

    DOEpatents

    Lee, Yin-Nan E.; Weber, Rodney J.; Orsini, Douglas

    2006-04-18

    An apparatus for continuous on-line measurement of chemical composition of aerosol particles with a fast time resolution is provided. The apparatus includes an enhanced particle size magnifier for producing activated aerosol particles and an enhanced collection device which collects the activated aerosol particles into a liquid stream for quantitative analysis by analytical means. Methods for on-line measurement of chemical composition of aerosol particles are also provided, the method including exposing aerosol carrying sample air to hot saturated steam thereby forming activated aerosol particles; collecting the activated aerosol particles by a collection device for delivery as a jet stream onto an impaction surface; and flushing off the activated aerosol particles from the impaction surface into a liquid stream for delivery of the collected liquid stream to an analytical instrument for quantitative measurement.

  2. The Effect of Brain Based Learning on Academic Achievement: A Meta-Analytical Study

    ERIC Educational Resources Information Center

    Gozuyesil, Eda; Dikici, Ayhan

    2014-01-01

    This study's aim is to measure the effect sizes of the quantitative studies that examined the effectiveness of brain-based learning on students' academic achievement and to examine with the meta-analytical method if there is a significant difference in effect in terms of the factors of education level, subject matter, sampling size, and the…

  3. Analytical methods in sphingolipidomics: Quantitative and profiling approaches in food analysis.

    PubMed

    Canela, Núria; Herrero, Pol; Mariné, Sílvia; Nadal, Pedro; Ras, Maria Rosa; Rodríguez, Miguel Ángel; Arola, Lluís

    2016-01-08

    In recent years, sphingolipidomics has emerged as an interesting omic science that encompasses the study of the full sphingolipidome characterization, content, structure and activity in cells, tissues or organisms. Like other omics, it has the potential to impact biomarker discovery, drug development and systems biology knowledge. Concretely, dietary food sphingolipids have gained considerable importance due to their extensively reported bioactivity. Because of the complexity of this lipid family and their diversity among foods, powerful analytical methodologies are needed for their study. The analytical tools developed in the past have been improved with the enormous advances made in recent years in mass spectrometry (MS) and chromatography, which allow the convenient and sensitive identification and quantitation of sphingolipid classes and form the basis of current sphingolipidomics methodologies. In addition, novel hyphenated nuclear magnetic resonance (NMR) strategies, new ionization strategies, and MS imaging are outlined as promising technologies to shape the future of sphingolipid analyses. This review traces the analytical methods of sphingolipidomics in food analysis concerning sample extraction, chromatographic separation, the identification and quantification of sphingolipids by MS and their structural elucidation by NMR. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Development of Mass Spectrometric Ionization Methods for Fullerenes and Fullerene Derivatives

    EPA Science Inventory

    Currently investigations into the environmental behavior of fullerenes and fullerene derivatives is hampered by the lack of well characterized standards and by the lack of readily available quantitative analytical methods. Reported herein are investigations into the utility of ma...

  5. Quantitative analysis of periodontal pathogens by ELISA and real-time polymerase chain reaction.

    PubMed

    Hamlet, Stephen M

    2010-01-01

    The development of analytical methods enabling the accurate identification and enumeration of bacterial species colonizing the oral cavity has led to the identification of a small number of bacterial pathogens that are major factors in the etiology of periodontal disease. Further, these methods also underpin more recent epidemiological analyses of the impact of periodontal disease on general health. Given the complex milieu of over 700 species of microorganisms known to exist within the complex biofilms found in the oral cavity, the identification and enumeration of oral periodontopathogens has not been an easy task. In recent years however, some of the intrinsic limitations of the more traditional microbiological analyses previously used have been overcome with the advent of immunological and molecular analytical methods. Of the plethora of methodologies reported in the literature, the enzyme-linked immunosorbent assay (ELISA), which combines the specificity of antibody with the sensitivity of simple enzyme assays and the polymerase chain reaction (PCR), has been widely utilized in both laboratory and clinical applications. Although conventional PCR does not allow quantitation of the target organism, real-time PCR (rtPCR) has the ability to detect amplicons as they accumulate in "real time" allowing subsequent quantitation. These methods enable the accurate quantitation of as few as 10(2) (using rtPCR) to 10(4) (using ELISA) periodontopathogens in dental plaque samples.

  6. Detection of biological molecules using boronate-based chemical amplification and optical sensors

    DOEpatents

    Van Antwerp, William Peter; Mastrototaro, John Joseph; Lane, Stephen M.; Satcher, Jr., Joe H.; Darrow, Christopher B.; Peyser, Thomas A.; Harder, Jennifer

    1999-01-01

    Methods are provided for the determination of the concentration of biological levels of polyhydroxylated compounds, particularly glucose. The methods utilize an amplification system that is an analyte transducer immobilized in a polymeric matrix, where the system is implantable and biocompatible. Upon interrogation by an optical system, the amplification system produces a signal capable of detection external to the skin of the patient. Quantitation of the analyte of interest is achieved by measurement of the emitted signal.

  7. Detection of biological molecules using boronate-based chemical amplification and optical sensors

    DOEpatents

    Van Antwerp, William Peter; Mastrototaro, John Joseph; Lane, Stephen M.; Satcher, Jr., Joe H.; Darrow, Christopher B.; Peyser, Thomas A.; Harder, Jennifer

    2004-06-15

    Methods are provided for the determination of the concentration of biological levels of polyhydroxylated compounds, particularly glucose. The methods utilize an amplification system that is an analyte transducer immobilized in a polymeric matrix, where the system is implantable and biocompatible. Upon interrogation by an optical system, the amplification system produces a signal capable of detection external to the skin of the patient. Quantitation of the analyte of interest is achieved by measurement of the emitted signal.

  8. Development and validation of an RP-HPLC method for quantitative determination of vanillin and related phenolic compounds in Vanilla planifolia.

    PubMed

    Sinha, Arun Kumar; Verma, Subash Chandra; Sharma, Upendra Kumar

    2007-01-01

    A simple and fast method was developed using RP-HPLC for separation and quantitative determination of vanillin and related phenolic compounds in ethanolic extract of pods of Vanilla planifolia. Ten phenolic compounds, namely 4-hydroxybenzyl alcohol, vanillyl alcohol, 3,4-dihydroxybenzaldehyde, 4-hydroxybenzoic acid, vanillic acid, 4-hydroxybenzaldehyde, vanillin, p-coumaric acid, ferulic acid, and piperonal were quantitatively determined using ACN, methanol, and 0.2% acetic acid in water as a mobile phase with a gradient elution mode. The method showed good linearity, high precision, and good recovery of compounds of interest. The present method would be useful for analytical research and for routine analysis of vanilla extracts for their quality control.

  9. OXYGEN-18 STUDY OF SO2 OXIDATION IN RAINWATER BY PEROXIDES

    EPA Science Inventory

    A new analytical method was developed for the determination of oxygen isotope ratios in peroxides in rainwater. In the method, rainwater samples were quantitatively degassed of dissolved air by a combined treatment of evacuation, ultrasonic agitation, and helium sparging (VUS), f...

  10. An HPLC method for determination of azadirachtin residues in bovine muscle.

    PubMed

    Gai, María Nella; Álvarez, Christian; Venegas, Raúl; Morales, Javier

    2011-04-01

    A high-performance liquid chromatography (HPLC) method for the determination of azadirachtin (A and B) residues in bovine muscle has been developed. Azadirachtin is a neutral triterpene and chemotherapeutic agent effective in controlling some pest flies in horses, stables, horns and fruit. The actual HPLC method uses an isocratic elution and UV detection. Liquid-liquid extraction and solid-phase purification was used for the clean-up of the biological matrix. The chromatographic determination of these components is achieved using a C18 analytical column with water-acetonitrile mixture (27.5:72.5, v/v) as mobile phase, 1 mL/min as flow rate, 45 °C column temperature and UV detector at 215 nm. The azadirachtin peaks are well resolved and free of interference from matrix components. The extraction and analytical method developed in this work allows the quantitation of azadirachtin with precision and accuracy, establishing a lower limit of quantitation of azadirachtin, extracted from the biological matrix.

  11. Targeted Quantitation of Proteins by Mass Spectrometry

    PubMed Central

    2013-01-01

    Quantitative measurement of proteins is one of the most fundamental analytical tasks in a biochemistry laboratory, but widely used immunochemical methods often have limited specificity and high measurement variation. In this review, we discuss applications of multiple-reaction monitoring (MRM) mass spectrometry, which allows sensitive, precise quantitative analyses of peptides and the proteins from which they are derived. Systematic development of MRM assays is permitted by databases of peptide mass spectra and sequences, software tools for analysis design and data analysis, and rapid evolution of tandem mass spectrometer technology. Key advantages of MRM assays are the ability to target specific peptide sequences, including variants and modified forms, and the capacity for multiplexing that allows analysis of dozens to hundreds of peptides. Different quantitative standardization methods provide options that balance precision, sensitivity, and assay cost. Targeted protein quantitation by MRM and related mass spectrometry methods can advance biochemistry by transforming approaches to protein measurement. PMID:23517332

  12. Targeted quantitation of proteins by mass spectrometry.

    PubMed

    Liebler, Daniel C; Zimmerman, Lisa J

    2013-06-04

    Quantitative measurement of proteins is one of the most fundamental analytical tasks in a biochemistry laboratory, but widely used immunochemical methods often have limited specificity and high measurement variation. In this review, we discuss applications of multiple-reaction monitoring (MRM) mass spectrometry, which allows sensitive, precise quantitative analyses of peptides and the proteins from which they are derived. Systematic development of MRM assays is permitted by databases of peptide mass spectra and sequences, software tools for analysis design and data analysis, and rapid evolution of tandem mass spectrometer technology. Key advantages of MRM assays are the ability to target specific peptide sequences, including variants and modified forms, and the capacity for multiplexing that allows analysis of dozens to hundreds of peptides. Different quantitative standardization methods provide options that balance precision, sensitivity, and assay cost. Targeted protein quantitation by MRM and related mass spectrometry methods can advance biochemistry by transforming approaches to protein measurement.

  13. Rapid Quantitation of Furanocoumarins and Flavonoids in Grapefruit Juice using Ultra Performance Liquid Chromatography

    PubMed Central

    VanderMolen, Karen M.; Cech, Nadja B.; Paine, Mary F.

    2013-01-01

    Introduction Grapefruit juice can increase or decrease the systemic exposure of myriad oral medications, leading to untoward effects or reduced efficacy. Furanocoumarins in grapefruit juice have been established as inhibitors of cytochrome P450 3A (CYP3A)-mediated metabolism and P-glycoprotein (P-gp)-mediated efflux, while flavonoids have been implicated as inhibitors of organic anion transporting polypeptide (OATP)-mediated absorptive uptake in the intestine. The potential for drug interactions with a food product necessitates an understanding of the expected concentrations of a suite of structurally diverse and potentially bioactive compounds. Objective Develop methods for the rapid quantitation of two furanocoumarins (bergamottin and 6′,7′-dihydroxybergamottin) and four flavonoids (naringin, naringenin, narirutin, and hesperidin) in five grapefruit juice products using ultra performance liquid chromatography (UPLC). Methodology Grapefruit juice products were extracted with ethyl acetate; the concentrated extract was analyzed by UPLC using acetonitrile:water gradients and a C18 column. Analytes were detected using a photodiode array detector, set at 250 nm (furanocoumarins) and 310 nm (flavonoids). Intraday and interday precision and accuracy and limits of detection and quantitation were determined. Results Rapid (<5.0 min) UPLC methods were developed to measure the aforementioned furanocoumarins and flavonoids. R2 values for the calibration curves of all analytes were >0.999. Considerable between-juice variation in the concentrations of these compounds was observed, and the quantities measured were in agreement with the concentrations published in HPLC studies. Conclusion These analytical methods provide an expedient means to quantitate key furanocoumarins and flavonoids in grapefruit juice and other foods used in dietary substance-drug interaction studies. PMID:23780830

  14. Rapid Quantitation of Furanocoumarins and Flavonoids in Grapefruit Juice using Ultra-Performance Liquid Chromatography.

    PubMed

    Vandermolen, Karen M; Cech, Nadja B; Paine, Mary F; Oberlies, Nicholas H

    2013-01-01

    Grapefruit juice can increase or decrease the systemic exposure of myriad oral medications, leading to untoward effects or reduced efficacy. Furanocoumarins in grapefruit juice have been established as inhibitors of cytochrome P450 3A (CYP3A)-mediated metabolism and P-glycoprotein (P-gp)-mediated efflux, while flavonoids have been implicated as inhibitors of organic anion transporting polypeptide (OATP)-mediated absorptive uptake in the intestine. The potential for drug interactions with a food product necessitates an understanding of the expected concentrations of a suite of structurally diverse and potentially bioactive compounds. Develop methods for the rapid quantitation of two furanocoumarins (bergamottin and 6',7'-dihydroxybergamottin) and four flavonoids (naringin, naringenin, narirutin and hesperidin) in five grapefruit juice products using ultra-performance liquid chromatography (UPLC). Grapefruit juice products were extracted with ethyl acetate; the concentrated extract was analysed by UPLC using acetonitrile:water gradients and a C18 -column. Analytes were detected using a photodiode array detector, set at 250 nm (furanocoumarins) and 310 nm (flavonoids). Intraday and interday precision and accuracy and limits of detection and quantitation were determined. Rapid (< 5.0 min) UPLC methods were developed to measure the aforementioned furanocoumarins and flavonoids. R(2) values for the calibration curves of all analytes were >0.999. Considerable between-juice variation in the concentrations of these compounds was observed, and the quantities measured were in agreement with the concentrations published in HPLC studies. These analytical methods provide an expedient means to quantitate key furanocoumarins and flavonoids in grapefruit juice and other foods used in dietary substance-drug interaction studies. Copyright © 2013 John Wiley & Sons, Ltd.

  15. Metrological approach to quantitative analysis of clinical samples by LA-ICP-MS: A critical review of recent studies.

    PubMed

    Sajnóg, Adam; Hanć, Anetta; Barałkiewicz, Danuta

    2018-05-15

    Analysis of clinical specimens by imaging techniques allows to determine the content and distribution of trace elements on the surface of the examined sample. In order to obtain reliable results, the developed procedure should be based not only on the properly prepared sample and performed calibration. It is also necessary to carry out all phases of the procedure in accordance with the principles of chemical metrology whose main pillars are the use of validated analytical methods, establishing the traceability of the measurement results and the estimation of the uncertainty. This review paper discusses aspects related to sampling, preparation and analysis of clinical samples by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) with emphasis on metrological aspects, i.e. selected validation parameters of the analytical method, the traceability of the measurement result and the uncertainty of the result. This work promotes the introduction of metrology principles for chemical measurement with emphasis to the LA-ICP-MS which is the comparative method that requires studious approach to the development of the analytical procedure in order to acquire reliable quantitative results. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Quantitative Determination of NTA and Other Chelating Agents in Detergents by Potentiometric Titration with Copper Ion Selective Electrode.

    PubMed

    Ito, Sana; Morita, Masaki

    2016-01-01

    Quantitative analysis of nitrilotriacetate (NTA) in detergents by titration with Cu 2+ solution using a copper ion selective electrode was achieved. This method tolerates a wide range of pH and ingredients in detergents. In addition to NTA, other chelating agents, having relatively lower stability constants toward Cu 2+ , were also qualified with sufficient accuracy by this analytical method for model detergent formulations. The titration process was automated by automatic titrating systems available commercially.

  17. A Digital Mixed Methods Research Design: Integrating Multimodal Analysis with Data Mining and Information Visualization for Big Data Analytics

    ERIC Educational Resources Information Center

    O'Halloran, Kay L.; Tan, Sabine; Pham, Duc-Son; Bateman, John; Vande Moere, Andrew

    2018-01-01

    This article demonstrates how a digital environment offers new opportunities for transforming qualitative data into quantitative data in order to use data mining and information visualization for mixed methods research. The digital approach to mixed methods research is illustrated by a framework which combines qualitative methods of multimodal…

  18. EPA Method 525.3 - Determination of Semivolatile Organic Chemicals in Drinking Water by Solid Phase Extraction and Capillary Column Gas Chromatography/Mass Spectrometry (GC/MS)

    EPA Science Inventory

    Method 525.3 is an analytical method that uses solid phase extraction (SPE) and gas chromatography/mass spectrometry (GC/MS) for the identification and quantitation of 125 selected semi-volatile organic chemicals in drinking water.

  19. Calibrant-Free Analyte Quantitation via a Variable Velocity Flow Cell.

    PubMed

    Beck, Jason G; Skuratovsky, Aleksander; Granger, Michael C; Porter, Marc D

    2017-01-17

    In this paper, we describe a novel method for analyte quantitation that does not rely on calibrants, internal standards, or calibration curves but, rather, leverages the relationship between disparate and predictable surface-directed analyte flux to an array of sensing addresses and a measured resultant signal. To reduce this concept to practice, we fabricated two flow cells such that the mean linear fluid velocity, U, was varied systematically over an array of electrodes positioned along the flow axis. This resulted in a predictable variation of the address-directed flux of a redox analyte, ferrocenedimethanol (FDM). The resultant limiting currents measured at a series of these electrodes, and accurately described by a convective-diffusive transport model, provided a means to calculate an "unknown" concentration without the use of calibrants, internal standards, or a calibration curve. Furthermore, the experiment and concentration calculation only takes minutes to perform. Deviation in calculated FDM concentrations from true values was minimized to less than 0.5% when empirically derived values of U were employed.

  20. Learning Analytics at Low Cost: At-Risk Student Prediction with Clicker Data and Systematic Proactive Interventions

    ERIC Educational Resources Information Center

    Choi, Samuel P. M.; Lam, S. S.; Li, Kam Cheong; Wong, Billy T. M.

    2018-01-01

    While learning analytics (LA) practices have been shown to be practical and effective, most of them require a huge amount of data and effort. This paper reports a case study which demonstrates the feasibility of practising LA at a low cost for instructors to identify at-risk students in an undergraduate business quantitative methods course.…

  1. Development of a fast liquid chromatography-tandem mass spectrometry method for the determination of endocrine-disrupting compounds in waters.

    PubMed

    Di Carro, Marina; Scapolla, Carlo; Liscio, Camilla; Magi, Emanuele

    2010-09-01

    A fast liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS-MS) method was developed to study five endocrine-disrupting compounds (4-n-nonylphenol, bisphenol A, estrone, 17β-estradiol and 17α-ethinylestradiol) in water. Different columns were tested; the chromatographic separation of the analytes was optimized on a Pinnacle DB biphenylic column with a water-acetonitrile gradient elution, which allowed the separation of the selected endocrine-disrupting compounds (EDCs) in less than 6 min. Quantitative analysis was performed in selected reaction monitoring (SRM) mode; two transitions were chosen for each compound, using the most abundant for quantitation. Calibration curves using bisphenol A-d (16) as internal standard were drawn, showing good correlation coefficients (0.9993-0.9998). All figures of merit of the method were satisfactory; limits of detection were in the low pg range for all analytes. The method was then applied to the determination of the analytes in real water samples: to this aim, polar organic chemical integrative samplers (POCIS) were deployed in the influent and in the effluent of a drinking water treatment plant in Liguria (Italy). The EDC level was rather low in the influent and negligible in the outlet, reflecting the expected function of the treatment plant.

  2. Extended internal standard method for quantitative 1H NMR assisted by chromatography (EIC) for analyte overlapping impurity on 1H NMR spectra.

    PubMed

    Saito, Naoki; Kitamaki, Yuko; Otsuka, Satoko; Yamanaka, Noriko; Nishizaki, Yuzo; Sugimoto, Naoki; Imura, Hisanori; Ihara, Toshihide

    2018-07-01

    We devised a novel extended internal standard method of quantitative 1 H NMR (qNMR) assisted by chromatography (EIC) that accurately quantifies 1 H signal areas of analytes, even when the chemical shifts of the impurity and analyte signals overlap completely. When impurity and analyte signals overlap in the 1 H NMR spectrum but can be separated in a chromatogram, the response ratio of the impurity and an internal standard (IS) can be obtained from the chromatogram. If the response ratio can be converted into the 1 H signal area ratio of the impurity and the IS, the 1 H signal area of the analyte can be evaluated accurately by mathematically correcting the contributions of the 1 H signal area of the impurity overlapping the analyte in the 1 H NMR spectrum. In this study, gas chromatography and liquid chromatography were used. We used 2-chlorophenol and 4-chlorophenol containing phenol as an impurity as examples in which impurity and analyte signals overlap to validate and demonstrate the EIC, respectively. Because the 1 H signals of 2-chlorophenol and phenol can be separated in specific alkaline solutions, 2-chlorophenol is suitable to validate the EIC by comparing analytical value obtained by the EIC with that by only qNMR under the alkaline condition. By the EIC, the purity of 2-chlorophenol was obtained with a relative expanded uncertainty (k = 2) of 0.24%. The purity matched that obtained under the alkaline condition. Furthermore, the EIC was also validated by evaluating the phenol content with the absolute calibration curve method by gas chromatography. Finally, we demonstrated that the EIC was possible to evaluate the purity of 4-chlorophenol, with a relative expanded uncertainty (k = 2) of 0.22%, which was not able to be separated from the 1 H signal of phenol under any condition. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Rapid qualitative and quantitative analysis of proanthocyanidin oligomers and polymers by UPLC-MS/MS

    USDA-ARS?s Scientific Manuscript database

    Proanthocyanidins (PAs) are a structurally complex and bioactive group of tannins. Detailed analysis of PA concentration, composition, and structure typically requires the use of one or more time-consuming analytical methods. For example, the commonly employed thiolysis and phloroglucinolysis method...

  4. To Demonstrate the Specificity of an Enzymatic Method for Plasma Paracetamol Estimation.

    ERIC Educational Resources Information Center

    O'Mullane, John A.

    1987-01-01

    Describes an experiment designed to introduce biochemistry students to the specificity of an analytical method which uses an enzyme to quantitate its substrate. Includes the use of toxicity charts together with the concept of the biological half-life of a drug. (TW)

  5. Analytical method for nitroaromatic explosives in radiologically contaminated soil for ISO/IEC 17025 accreditation

    DOE PAGES

    Boggess, Andrew; Crump, Stephen; Gregory, Clint; ...

    2017-12-06

    Here, unique hazards are presented in the analysis of radiologically contaminated samples. Strenuous safety and security precautions must be in place to protect the analyst, laboratory, and instrumentation used to perform analyses. A validated method has been optimized for the analysis of select nitroaromatic explosives and degradative products using gas chromatography/mass spectrometry via sonication extraction of radiologically contaminated soils, for samples requiring ISO/IEC 17025 laboratory conformance. Target analytes included 2-nitrotoluene, 4-nitrotoluene, 2,6-dinitrotoluene, and 2,4,6-trinitrotoluene, as well as the degradative product 4-amino-2,6-dinitrotoluene. Analytes were extracted from soil in methylene chloride by sonication. Administrative and engineering controls, as well as instrument automationmore » and quality control measures, were utilized to minimize potential human exposure to radiation at all times and at all stages of analysis, from receiving through disposition. Though thermal instability increased uncertainties of these selected compounds, a mean lower quantitative limit of 2.37 µg/mL and mean accuracy of 2.3% relative error and 3.1% relative standard deviation were achieved. Quadratic regression was found to be optimal for calibration of all analytes, with compounds of lower hydrophobicity displaying greater parabolic curve. Blind proficiency testing (PT) of spiked soil samples demonstrated a mean relative error of 9.8%. Matrix spiked analyses of PT samples demonstrated that 99% recovery of target analytes was achieved. To the knowledge of the authors, this represents the first safe, accurate, and reproducible quantitative method for nitroaromatic explosives in soil for specific use on radiologically contaminated samples within the constraints of a nuclear analytical lab.« less

  6. Analytical method for nitroaromatic explosives in radiologically contaminated soil for ISO/IEC 17025 accreditation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boggess, Andrew; Crump, Stephen; Gregory, Clint

    Here, unique hazards are presented in the analysis of radiologically contaminated samples. Strenuous safety and security precautions must be in place to protect the analyst, laboratory, and instrumentation used to perform analyses. A validated method has been optimized for the analysis of select nitroaromatic explosives and degradative products using gas chromatography/mass spectrometry via sonication extraction of radiologically contaminated soils, for samples requiring ISO/IEC 17025 laboratory conformance. Target analytes included 2-nitrotoluene, 4-nitrotoluene, 2,6-dinitrotoluene, and 2,4,6-trinitrotoluene, as well as the degradative product 4-amino-2,6-dinitrotoluene. Analytes were extracted from soil in methylene chloride by sonication. Administrative and engineering controls, as well as instrument automationmore » and quality control measures, were utilized to minimize potential human exposure to radiation at all times and at all stages of analysis, from receiving through disposition. Though thermal instability increased uncertainties of these selected compounds, a mean lower quantitative limit of 2.37 µg/mL and mean accuracy of 2.3% relative error and 3.1% relative standard deviation were achieved. Quadratic regression was found to be optimal for calibration of all analytes, with compounds of lower hydrophobicity displaying greater parabolic curve. Blind proficiency testing (PT) of spiked soil samples demonstrated a mean relative error of 9.8%. Matrix spiked analyses of PT samples demonstrated that 99% recovery of target analytes was achieved. To the knowledge of the authors, this represents the first safe, accurate, and reproducible quantitative method for nitroaromatic explosives in soil for specific use on radiologically contaminated samples within the constraints of a nuclear analytical lab.« less

  7. An approach to estimate spatial distribution of analyte within cells using spectrally-resolved fluorescence microscopy.

    PubMed

    Sharma, Dharmendar Kumar; Irfanullah, Mir; Basu, Santanu Kumar; Madhu, Sheri; De, Suman; Jadhav, Sameer; Ravikanth, Mangalampalli; Chowdhury, Arindam

    2017-01-18

    While fluorescence microscopy has become an essential tool amongst chemists and biologists for the detection of various analyte within cellular environments, non-uniform spatial distribution of sensors within cells often restricts extraction of reliable information on relative abundance of analytes in different subcellular regions. As an alternative to existing sensing methodologies such as ratiometric or FRET imaging, where relative proportion of analyte with respect to the sensor can be obtained within cells, we propose a methodology using spectrally-resolved fluorescence microscopy, via which both the relative abundance of sensor as well as their relative proportion with respect to the analyte can be simultaneously extracted for local subcellular regions. This method is exemplified using a BODIPY sensor, capable of detecting mercury ions within cellular environments, characterized by spectral blue-shift and concurrent enhancement of emission intensity. Spectral emission envelopes collected from sub-microscopic regions allowed us to compare the shift in transition energies as well as integrated emission intensities within various intracellular regions. Construction of a 2D scatter plot using spectral shifts and emission intensities, which depend on the relative amount of analyte with respect to sensor and the approximate local amounts of the probe, respectively, enabled qualitative extraction of relative abundance of analyte in various local regions within a single cell as well as amongst different cells. Although the comparisons remain semi-quantitative, this approach involving analysis of multiple spectral parameters opens up an alternative way to extract spatial distribution of analyte in heterogeneous systems. The proposed method would be especially relevant for fluorescent probes that undergo relatively nominal shift in transition energies compared to their emission bandwidths, which often restricts their usage for quantitative ratiometric imaging in cellular media due to strong cross-talk between energetically separated detection channels.

  8. An approach to estimate spatial distribution of analyte within cells using spectrally-resolved fluorescence microscopy

    NASA Astrophysics Data System (ADS)

    Sharma, Dharmendar Kumar; Irfanullah, Mir; Basu, Santanu Kumar; Madhu, Sheri; De, Suman; Jadhav, Sameer; Ravikanth, Mangalampalli; Chowdhury, Arindam

    2017-03-01

    While fluorescence microscopy has become an essential tool amongst chemists and biologists for the detection of various analyte within cellular environments, non-uniform spatial distribution of sensors within cells often restricts extraction of reliable information on relative abundance of analytes in different subcellular regions. As an alternative to existing sensing methodologies such as ratiometric or FRET imaging, where relative proportion of analyte with respect to the sensor can be obtained within cells, we propose a methodology using spectrally-resolved fluorescence microscopy, via which both the relative abundance of sensor as well as their relative proportion with respect to the analyte can be simultaneously extracted for local subcellular regions. This method is exemplified using a BODIPY sensor, capable of detecting mercury ions within cellular environments, characterized by spectral blue-shift and concurrent enhancement of emission intensity. Spectral emission envelopes collected from sub-microscopic regions allowed us to compare the shift in transition energies as well as integrated emission intensities within various intracellular regions. Construction of a 2D scatter plot using spectral shifts and emission intensities, which depend on the relative amount of analyte with respect to sensor and the approximate local amounts of the probe, respectively, enabled qualitative extraction of relative abundance of analyte in various local regions within a single cell as well as amongst different cells. Although the comparisons remain semi-quantitative, this approach involving analysis of multiple spectral parameters opens up an alternative way to extract spatial distribution of analyte in heterogeneous systems. The proposed method would be especially relevant for fluorescent probes that undergo relatively nominal shift in transition energies compared to their emission bandwidths, which often restricts their usage for quantitative ratiometric imaging in cellular media due to strong cross-talk between energetically separated detection channels. Dedicated to Professor Kankan Bhattacharyya.

  9. Quantitative estimation of minimum offset for multichannel surface-wave survey with actively exciting source

    USGS Publications Warehouse

    Xu, Y.; Xia, J.; Miller, R.D.

    2006-01-01

    Multichannel analysis of surface waves is a developing method widely used in shallow subsurface investigations. The field procedures and related parameters are very important for successful applications. Among these parameters, the source-receiver offset range is seldom discussed in theory and normally determined by empirical or semi-quantitative methods in current practice. This paper discusses the problem from a theoretical perspective. A formula for quantitatively evaluating a layered homogenous elastic model was developed. The analytical results based on simple models and experimental data demonstrate that the formula is correct for surface wave surveys for near-surface applications. ?? 2005 Elsevier B.V. All rights reserved.

  10. Do placebo based validation standards mimic real batch products behaviour? Case studies.

    PubMed

    Bouabidi, A; Talbi, M; Bouklouze, A; El Karbane, M; Bourichi, H; El Guezzar, M; Ziemons, E; Hubert, Ph; Rozet, E

    2011-06-01

    Analytical methods validation is a mandatory step to evaluate the ability of developed methods to provide accurate results for their routine application. Validation usually involves validation standards or quality control samples that are prepared in placebo or reconstituted matrix made of a mixture of all the ingredients composing the drug product except the active substance or the analyte under investigation. However, one of the main concerns that can be made with this approach is that it may lack an important source of variability that come from the manufacturing process. The question that remains at the end of the validation step is about the transferability of the quantitative performance from validation standards to real authentic drug product samples. In this work, this topic is investigated through three case studies. Three analytical methods were validated using the commonly spiked placebo validation standards at several concentration levels as well as using samples coming from authentic batch samples (tablets and syrups). The results showed that, depending on the type of response function used as calibration curve, there were various degrees of differences in the results accuracy obtained with the two types of samples. Nonetheless the use of spiked placebo validation standards was showed to mimic relatively well the quantitative behaviour of the analytical methods with authentic batch samples. Adding these authentic batch samples into the validation design may help the analyst to select and confirm the most fit for purpose calibration curve and thus increase the accuracy and reliability of the results generated by the method in routine application. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Analytical capabilities of high performance liquid chromatography - Atmospheric pressure photoionization - Orbitrap mass spectrometry (HPLC-APPI-Orbitrap-MS) for the trace determination of novel and emerging flame retardants in fish.

    PubMed

    Zacs, D; Bartkevics, V

    2015-10-22

    A new analytical method was established and validated for the analysis of 27 brominated flame retardants (BFRs), including so called "emerging" and "novel" BFRs (EBFRs and NBFRs) in fish samples. High performance liquid chromatography (HPLC) coupled to Orbitrap mass spectrometry (Orbitrap-MS) employing atmospheric pressure photoionization (APPI) interface operated in negative mode was used for the identification/quantitation of contaminants. HPLC-Orbitrap-MS analysis provided a fast separation of selected analytes within 14 min, thus demonstrating a high throughput processing of samples. The developed methodology was tested by intralaboratory validation in terms of recovery, repeatability, linear calibration ranges, instrumental and method limits of quantitation (i-LOQ and m-LOQ), and where possible, trueness was verified by analysis of certified reference materials (CRMs). Recoveries of analytes were between 80 and 119%, while the repeatability in terms of relative standard deviations (RSDs) was in the range from 1.2 to 15.5%. The measured values for both analyzed CRMs agreed with the provided consensus values, revealing the recovery of reference concentrations in 72-119% range. The elaborated method met the sensitivity criterion according to Commission Recommendation 2014/118/EU on monitoring of BFRs in food products for majority of the compounds. The concentrations of polybrominated diphenyl ethers (PBDEs) in real samples determined by HPLC-APPI-Orbitrap-MS method and validated gas chromatography-high-resolution mass spectrometry (GC-HRMS) method were found to be in a good agreement. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. [Sample preparation and bioanalysis in mass spectrometry].

    PubMed

    Bourgogne, Emmanuel; Wagner, Michel

    2015-01-01

    The quantitative analysis of compounds of clinical interest of low molecular weight (<1000 Da) in biological fluids is currently in most cases performed by liquid chromatography-mass spectrometry (LC-MS). Analysis of these compounds in biological fluids (plasma, urine, saliva, hair...) is a difficult task requiring a sample preparation. Sample preparation is a crucial part of chemical/biological analysis and in a sense is considered the bottleneck of the whole analytical process. The main objectives of sample preparation are the removal of potential interferences, analyte preconcentration, and converting (if needed) the analyte into a more suitable form for detection or separation. Without chromatographic separation, endogenous compounds, co-eluted products may affect a quantitative method in mass spectrometry performance. This work focuses on three distinct parts. First, quantitative bioanalysis will be defined, different matrices and sample preparation techniques currently used in bioanalysis by mass spectrometry of/for small molecules of clinical interest in biological fluids. In a second step the goals of sample preparation will be described. Finally, in a third step, sample preparation strategies will be made either directly ("dilute and shoot") or after precipitation.

  13. Biological Matrix Effects in Quantitative Tandem Mass Spectrometry-Based Analytical Methods: Advancing Biomonitoring

    PubMed Central

    Panuwet, Parinya; Hunter, Ronald E.; D’Souza, Priya E.; Chen, Xianyu; Radford, Samantha A.; Cohen, Jordan R.; Marder, M. Elizabeth; Kartavenka, Kostya; Ryan, P. Barry; Barr, Dana Boyd

    2015-01-01

    The ability to quantify levels of target analytes in biological samples accurately and precisely, in biomonitoring, involves the use of highly sensitive and selective instrumentation such as tandem mass spectrometers and a thorough understanding of highly variable matrix effects. Typically, matrix effects are caused by co-eluting matrix components that alter the ionization of target analytes as well as the chromatographic response of target analytes, leading to reduced or increased sensitivity of the analysis. Thus, before the desired accuracy and precision standards of laboratory data are achieved, these effects must be characterized and controlled. Here we present our review and observations of matrix effects encountered during the validation and implementation of tandem mass spectrometry-based analytical methods. We also provide systematic, comprehensive laboratory strategies needed to control challenges posed by matrix effects in order to ensure delivery of the most accurate data for biomonitoring studies assessing exposure to environmental toxicants. PMID:25562585

  14. Quantitating Organoleptic Volatile Phenols in Smoke-Exposed Vitis vinifera Berries.

    PubMed

    Noestheden, Matthew; Thiessen, Katelyn; Dennis, Eric G; Tiet, Ben; Zandberg, Wesley F

    2017-09-27

    Accurate methods for quantitating volatile phenols (i.e., guaiacol, syringol, 4-ethylphenol, etc.) in smoke-exposed Vitis vinifera berries prior to fermentation are needed to predict the likelihood of perceptible smoke taint following vinification. Reported here is a complete, cross-validated analytical workflow to accurately quantitate free and glycosidically bound volatile phenols in smoke-exposed berries using liquid-liquid extraction, acid-mediated hydrolysis, and gas chromatography-tandem mass spectrometry. The reported workflow addresses critical gaps in existing methods for volatile phenols that impact quantitative accuracy, most notably the effect of injection port temperature and the variability in acid-mediated hydrolytic procedures currently used. Addressing these deficiencies will help the wine industry make accurate, informed decisions when producing wines from smoke-exposed berries.

  15. The quantitative determination of cilostazol and its four metabolites in human liver microsomal incubation mixtures by high-performance liquid chromatography.

    PubMed

    Tata, P N; Fu, C H; Browder, N J; Chow, P C; Bramer, S L

    1998-11-01

    A high-performance liquid chromatography-ultraviolet (HPLC-UV) method for the quantitation of cilostazol and four of its principal metabolites (i.e. OPC-13015, OPC-13213, OPC-13217 and OPC-13326) in human liver microsomal solutions was developed and validated. Cilostazol, its metabolites, and the internal standard (OPC-3930), were analyzed by protein precipitation followed by reverse-phase HPLC separation on a TSK-Gel ODS-80TM (150 x 4.6 mm, 5 microm) column and a Cosmil C-18 column (150 x 4.6 mm, 5 microm) in tandem and UV detection at 254 nm. An 80 min gradient elution of mobile phase acetonitrile in acetate buffer (pH = 6.50) was used to obtain quality chromatography and peak resolution. All the analytes were separated from each other, with the resolution being 2.43-17.59. The components of liver microsomal incubation mixture and five metabolic inhibitor probes (quinidine sulfate, diethyl dithiocarbamate (DEDTC), omeprazole, ketoconazole and furafylline) did not interfere with this analytical method. The LOQ was 1000 ng ml(-1) for cilostazol and 100 ng ml(-1) for each of the metabolites. This method has been validated for linear ranges of 100-4000 ng ml(-1) for OPC-13213, OPC-13217 and OPC-13326; 100-2000 ng ml(-1) for OPC-13015; and 1000-20000 ng ml(-1) for cilostazol. The percent relative recovery of this method was established to be 81.2-101.0% for analytes, with the precision (% coefficient of variation (CV)) being 2.8-7.7%. The autosampler stability of the analytes was evaluated and it was found that all analytes were stable at room temperature for a period of at least 17 h. This assay has been shown to be precise, accurate and reproducible.

  16. Quantitation of cocaine and cocaethylene in small volumes of rat whole blood using gas chromatography-mass spectrometry.

    PubMed

    Burdick, J D; Boni, R L; Fochtman, F W

    1997-05-01

    A simple solid phase extraction (SPE) technique combined with gas chromatography-mass spectrometry (GC/MS) operated in selected ion monitoring (SIM) mode is described for quantitation of cocaine and cocaethylene in small samples (250 microliters) of rat whole blood. Use of (N-[2H3C])-cocaine and (N-[2H3C])-cocaethylene internal standards resulted in high sensitivity and selectivity for this analytical method. Analysis was performed using a Hewlett-Packard 5890 GC equipped with a 7673A Automatic Liquid Sampler linked to a Hewlett-Packard 5972 Mass Selective Detector. Separation of analytes was accomplished on a cross-linked methyl silicone gum capillary column (Ultra 1: 12m x 0.2mm (i.d.) x 0.33 microns). Linearity was established over a wide range of concentrations (5.0-2000.0 ng ml-1) with good precision. Limits of detection (LOD) were 1.0 and 2.0 ng ml-1 for cocaine and cocaethylene, respectively. This analytical method was designed for use in pharmacokinetic experiments studying the formation of cocaethylene following ethanol pretreatment in rats administered cocaine.

  17. Analytical Chemical Sensing in the Submillimeter/terahertz Spectral Range

    NASA Astrophysics Data System (ADS)

    Moran, Benjamin L.; Fosnight, Alyssa M.; Medvedev, Ivan R.; Neese, Christopher F.

    2012-06-01

    Highly sensitive and selective Terahertz sensor utilized to quantitatively analyze a complex mixture of Volatile Organic Compounds is reported. To best demonstrate analytical capabilities of THz chemical sensors we chose to perform analytical quantitative analysis of a certified gas mixture using a novel prototype chemical sensor that couples a commercial preconcentration system (Entech 7100A) to a high resolution THz spectrometer. We selected Method TO-14A certified mixture of 39 volatile organic compounds (VOCs) diluted to 1 part per million (ppm) in nitrogen. 26 of the 39 chemicals were identified by us as suitable for THz spectroscopic detection. Entech 7100A system is designed and marketed as an inlet system for Gas Chromatography-Mass Spectrometry (GC-MS) instruments with a specific focus on TO-14 and TO-15 EPA sampling methods. Its preconcentration efficiency is high for the 39 chemicals in the mixture used for this study and our preliminary results confirm this. Here we present the results of this study which serves as basis for our ongoing research in environmental sensing and analysis of exhaled human breath.

  18. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of selected carbamate pesticides in water by high-performance liquid chromatography

    USGS Publications Warehouse

    Werner, S.L.; Johnson, S.M.

    1994-01-01

    As part of its primary responsibility concerning water as a national resource, the U.S. Geological Survey collects and analyzes samples of ground water and surface water to determine water quality. This report describes the method used since June 1987 to determine selected total-recoverable carbamate pesticides present in water samples. High- performance liquid chromatography is used to separate N-methyl carbamates, N-methyl carbamoyloximes, and an N-phenyl carbamate which have been extracted from water and concentrated in dichloromethane. Analytes, surrogate compounds, and reference compounds are eluted from the analytical column within 25 minutes. Two modes of analyte detection are used: (1) a photodiode-array detector measures and records ultraviolet-absorbance profiles, and (2) a fluorescence detector measures and records fluorescence from an analyte derivative produced when analyte hydrolysis is combined with chemical derivatization. Analytes are identified and confirmed in a three-stage process by use of chromatographic retention time, ultraviolet (UV) spectral comparison, and derivatization/fluorescence detection. Quantitative results are based on the integration of single-wavelength UV-absorbance chromatograms and on comparison with calibration curves derived from external analyte standards that are run with samples as part of an instrumental analytical sequence. Estimated method detection limits vary for each analyte, depending on the sample matrix conditions, and range from 0.5 microgram per liter to as low as 0.01 microgram per liter. Reporting levels for all analytes have been set at 0.5 microgram per liter for this method. Corrections on the basis of percentage recoveries of analytes spiked into distilled water are not applied to values calculated for analyte concentration in samples. These values for analyte concentrations instead indicate the quantities recovered by the method from a particular sample matrix.

  19. [Local Regression Algorithm Based on Net Analyte Signal and Its Application in Near Infrared Spectral Analysis].

    PubMed

    Zhang, Hong-guang; Lu, Jian-gang

    2016-02-01

    Abstract To overcome the problems of significant difference among samples and nonlinearity between the property and spectra of samples in spectral quantitative analysis, a local regression algorithm is proposed in this paper. In this algorithm, net signal analysis method(NAS) was firstly used to obtain the net analyte signal of the calibration samples and unknown samples, then the Euclidean distance between net analyte signal of the sample and net analyte signal of calibration samples was calculated and utilized as similarity index. According to the defined similarity index, the local calibration sets were individually selected for each unknown sample. Finally, a local PLS regression model was built on each local calibration sets for each unknown sample. The proposed method was applied to a set of near infrared spectra of meat samples. The results demonstrate that the prediction precision and model complexity of the proposed method are superior to global PLS regression method and conventional local regression algorithm based on spectral Euclidean distance.

  20. Rapid, automated, parallel quantitative immunoassays using highly integrated microfluidics and AlphaLISA

    PubMed Central

    Tak For Yu, Zeta; Guan, Huijiao; Ki Cheung, Mei; McHugh, Walker M.; Cornell, Timothy T.; Shanley, Thomas P.; Kurabayashi, Katsuo; Fu, Jianping

    2015-01-01

    Immunoassays represent one of the most popular analytical methods for detection and quantification of biomolecules. However, conventional immunoassays such as ELISA and flow cytometry, even though providing high sensitivity and specificity and multiplexing capability, can be labor-intensive and prone to human error, making them unsuitable for standardized clinical diagnoses. Using a commercialized no-wash, homogeneous immunoassay technology (‘AlphaLISA’) in conjunction with integrated microfluidics, herein we developed a microfluidic immunoassay chip capable of rapid, automated, parallel immunoassays of microliter quantities of samples. Operation of the microfluidic immunoassay chip entailed rapid mixing and conjugation of AlphaLISA components with target analytes before quantitative imaging for analyte detections in up to eight samples simultaneously. Aspects such as fluid handling and operation, surface passivation, imaging uniformity, and detection sensitivity of the microfluidic immunoassay chip using AlphaLISA were investigated. The microfluidic immunoassay chip could detect one target analyte simultaneously for up to eight samples in 45 min with a limit of detection down to 10 pg mL−1. The microfluidic immunoassay chip was further utilized for functional immunophenotyping to examine cytokine secretion from human immune cells stimulated ex vivo. Together, the microfluidic immunoassay chip provides a promising high-throughput, high-content platform for rapid, automated, parallel quantitative immunosensing applications. PMID:26074253

  1. Combining qualitative and quantitative research within mixed method research designs: a methodological review.

    PubMed

    Östlund, Ulrika; Kidd, Lisa; Wengström, Yvonne; Rowa-Dewar, Neneh

    2011-03-01

    It has been argued that mixed methods research can be useful in nursing and health science because of the complexity of the phenomena studied. However, the integration of qualitative and quantitative approaches continues to be one of much debate and there is a need for a rigorous framework for designing and interpreting mixed methods research. This paper explores the analytical approaches (i.e. parallel, concurrent or sequential) used in mixed methods studies within healthcare and exemplifies the use of triangulation as a methodological metaphor for drawing inferences from qualitative and quantitative findings originating from such analyses. This review of the literature used systematic principles in searching CINAHL, Medline and PsycINFO for healthcare research studies which employed a mixed methods approach and were published in the English language between January 1999 and September 2009. In total, 168 studies were included in the results. Most studies originated in the United States of America (USA), the United Kingdom (UK) and Canada. The analytic approach most widely used was parallel data analysis. A number of studies used sequential data analysis; far fewer studies employed concurrent data analysis. Very few of these studies clearly articulated the purpose for using a mixed methods design. The use of the methodological metaphor of triangulation on convergent, complementary, and divergent results from mixed methods studies is exemplified and an example of developing theory from such data is provided. A trend for conducting parallel data analysis on quantitative and qualitative data in mixed methods healthcare research has been identified in the studies included in this review. Using triangulation as a methodological metaphor can facilitate the integration of qualitative and quantitative findings, help researchers to clarify their theoretical propositions and the basis of their results. This can offer a better understanding of the links between theory and empirical findings, challenge theoretical assumptions and develop new theory. Copyright © 2010 Elsevier Ltd. All rights reserved.

  2. An analytical approach based on ESI-MS, LC-MS and PCA for the quali-quantitative analysis of cycloartane derivatives in Astragalus spp.

    PubMed

    Napolitano, Assunta; Akay, Seref; Mari, Angela; Bedir, Erdal; Pizza, Cosimo; Piacente, Sonia

    2013-11-01

    Astragalus species are widely used as health foods and dietary supplements, as well as drugs in traditional medicine. To rapidly evaluate metabolite similarities and differences among the EtOH extracts of the roots of eight commercial Astragalus spp., an approach based on direct analyses by ESI-MS followed by PCA of ESI-MS data, was carried out. Successively, quali-quantitative analyses of cycloartane derivatives in the eight Astragalus spp. by LC-ESI-MS(n) and PCA of LC-ESI-MS data were performed. This approach allowed to promptly highlighting metabolite similarities and differences among the various Astragalus spp. PCA results from LC-ESI-MS data of Astragalus samples were in reasonable agreement with both PCA results of ESI-MS data and quantitative results. This study affords an analytical method for the quali-quantitative determination of cycloartane derivatives in herbal preparations used as health and food supplements. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Applying Mixed Methods Techniques in Strategic Planning

    ERIC Educational Resources Information Center

    Voorhees, Richard A.

    2008-01-01

    In its most basic form, strategic planning is a process of anticipating change, identifying new opportunities, and executing strategy. The use of mixed methods, blending quantitative and qualitative analytical techniques and data, in the process of assembling a strategic plan can help to ensure a successful outcome. In this article, the author…

  4. DETERMINATION OF CHLOROPHEONIS, NITROPHENOIS AND METHYLPHENOIS IN GROUND-WATER SAMPLES USING HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

    EPA Science Inventory

    A high performance liquid chromatography (HPLC) method was developed to quantitatively determine phenolic compounds and their isomers in aqueous samples. The HPLC method can analyze a mixture of 15 contaminants in the same analytical run with an analysis time of 25 minutes. The...

  5. Development of an analytical method to measure insoluble and soluble starch in sugarcane and sweet sorghum products

    USDA-ARS?s Scientific Manuscript database

    A rapid, quantitative research method using microwave-assisted probe ultrasonication was developed to facilitate the determination of total insoluble, and soluble starch in various sugar crop products. Several variables that affect starch solubilization were evaluated, 1) conductive boiling time, 2...

  6. DETERMINATION OF CHLOROPHENOLS, NITROPHENOLS, AND METHYLPHENOLS IN GROUND-WATER SAMPLES USING HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

    EPA Science Inventory

    A high performance liquid chromatography (HPLC) method was developed to quantitatively determine phenolic compounds and their isomers in aqueous samples. The HPLC method can analyze a mixture of 15 contaminants in the same analytical run with an analysis time of 25 minutes. The...

  7. Applicability of bioanalysis of multiple analytes in drug discovery and development: review of select case studies including assay development considerations.

    PubMed

    Srinivas, Nuggehally R

    2006-05-01

    The development of sound bioanalytical method(s) is of paramount importance during the process of drug discovery and development culminating in a marketing approval. Although the bioanalytical procedure(s) originally developed during the discovery stage may not necessarily be fit to support the drug development scenario, they may be suitably modified and validated, as deemed necessary. Several reviews have appeared over the years describing analytical approaches including various techniques, detection systems, automation tools that are available for an effective separation, enhanced selectivity and sensitivity for quantitation of many analytes. The intention of this review is to cover various key areas where analytical method development becomes necessary during different stages of drug discovery research and development process. The key areas covered in this article with relevant case studies include: (a) simultaneous assay for parent compound and metabolites that are purported to display pharmacological activity; (b) bioanalytical procedures for determination of multiple drugs in combating a disease; (c) analytical measurement of chirality aspects in the pharmacokinetics, metabolism and biotransformation investigations; (d) drug monitoring for therapeutic benefits and/or occupational hazard; (e) analysis of drugs from complex and/or less frequently used matrices; (f) analytical determination during in vitro experiments (metabolism and permeability related) and in situ intestinal perfusion experiments; (g) determination of a major metabolite as a surrogate for the parent molecule; (h) analytical approaches for universal determination of CYP450 probe substrates and metabolites; (i) analytical applicability to prodrug evaluations-simultaneous determination of prodrug, parent and metabolites; (j) quantitative determination of parent compound and/or phase II metabolite(s) via direct or indirect approaches; (k) applicability in analysis of multiple compounds in select disease areas and/or in clinically important drug-drug interaction studies. A tabular representation of select examples of analysis is provided covering areas of separation conditions, validation aspects and applicable conclusion. A limited discussion is provided on relevant aspects of the need for developing bioanalytical procedures for speedy drug discovery and development. Additionally, some key elements such as internal standard selection, likely issues of mass detection, matrix effect, chiral aspects etc. are provided for consideration during method development.

  8. Method for the analysis of triadimefon and ethofumesate from dislodgeable foliar residues on turfgrass by solid-phase extraction and in-vial elution.

    PubMed

    Runes, H B; Jenkins, J J; Field, J A

    1999-08-01

    Triadimefon, a fungicide, and ethofumesate, an herbicide, are commonly applied to turfgrass in the Pacific Northwest, resulting in foliar residues. A simple and rapid method was developed to determine triadimefon and ethofumesate concentrations from dislodgeable foliar residues on turfgrass. Turfgrass samples were washed, and wash water containing surfactant (a 0.126% solution) was collected for residue analysis. This analytical method utilizes a 25 mm C(8) Empore disk and in-vial elution to quantitatively determine triadimefon and ethofumesate in 170 mL aqueous samples. The analytes were eluted by placing the disk in a 2 mL autosampler vial with 980 microL of ethyl acetate and 20 microL of 2-chlorolepidine, the internal standard, for analysis by GC/MS. The method quantitation limits are 0.29 microg/L for ethofumesate and 0.59 microg/L for triadimefon. The method detection limits are 0.047 microg/L and 0.29 microg/L for ethofumesate and triadimefon, respectively. Concentrations of triadimefon and ethofumesate from dislodgeable foliar residues from a field study are reported.

  9. Multiplicative effects model with internal standard in mobile phase for quantitative liquid chromatography-mass spectrometry.

    PubMed

    Song, Mi; Chen, Zeng-Ping; Chen, Yao; Jin, Jing-Wen

    2014-07-01

    Liquid chromatography-mass spectrometry assays suffer from signal instability caused by the gradual fouling of the ion source, vacuum instability, aging of the ion multiplier, etc. To address this issue, in this contribution, an internal standard was added into the mobile phase. The internal standard was therefore ionized and detected together with the analytes of interest by the mass spectrometer to ensure that variations in measurement conditions and/or instrument have similar effects on the signal contributions of both the analytes of interest and the internal standard. Subsequently, based on the unique strategy of adding internal standard in mobile phase, a multiplicative effects model was developed for quantitative LC-MS assays and tested on a proof of concept model system: the determination of amino acids in water by LC-MS. The experimental results demonstrated that the proposed method could efficiently mitigate the detrimental effects of continuous signal variation, and achieved quantitative results with average relative predictive error values in the range of 8.0-15.0%, which were much more accurate than the corresponding results of conventional internal standard method based on the peak height ratio and partial least squares method (their average relative predictive error values were as high as 66.3% and 64.8%, respectively). Therefore, it is expected that the proposed method can be developed and extended in quantitative LC-MS analysis of more complex systems. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Quantitative detection of pathogens in centrifugal microfluidic disks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koh, Chung-Yan; Schaff, Ulrich Y.; Sommer, Gregory Jon

    A system and methods for detection of a nucleic acid including forming a plurality of nucleic acid detection complexes are described, each of the complexes including a nucleic acid analyte, a detection agent and a functionalized probe. The method further including binding the nucleic acid detection complexes to a plurality of functionalized particles in a fluid sample and separating the functionalized particles having the nucleic acid detection complexes bound thereto from the fluid sample using a density media. The nucleic acid analyte is detected by detecting the detection agent.

  11. Pressurized hot water extraction followed by miniaturized membrane assisted solvent extraction for the green analysis of alkylphenols in sediments.

    PubMed

    Salgueiro-González, N; Turnes-Carou, I; Muniategui-Lorenzo, S; López-Mahía, P; Prada-Rodríguez, D

    2015-02-27

    A novel and Green analytical methodology for the determination of alkylphenols (4-tert-octylphenol, 4-n-octylphenol, 4-n-nonylphenol, nonylphenol) in sediments was developed and validated. The method was based on pressurized hot water extraction (PHWE) followed by miniaturized membrane assisted solvent extraction (MASE) and liquid chromatography-electrospray ionization tandem mass spectrometry detection (LC-ESI-MS/MS). The extraction conditions were optimized by a Plackett-Burman design in order to minimize the number of assays according to Green principles. Matrix effect was studied and compensated using deuterated labeled standards as surrogate standards for the quantitation of the target compounds. The analytical features of the method were satisfactory: relative recoveries varied between 92 and 103% and repeatability and intermediate precision were <9% for all compounds. Quantitation limits of the method (MQL) ranged from 0.061 (4-n-nonylphenol) to 1.7ngg(-1) dry weight (nonylphenol). Sensitivity, selectivity, automaticity and fastness are the main advantages of the exposed methodology. Reagent consumption, analysis time and waste generation were minimized. The "greenness" of the proposed method was evaluated using an analytical Eco-Scale approach and satisfactory results were obtained. The applicability of the proposed method was demonstrated analysing sediment samples of Galicia coast (NW of Spain) and the ubiquity of alkylphenols in the environment was demonstrated. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Quantitative determination of the enantiomers of methadone in human plasma and saliva by chiral column chromatography coupled with mass spectrometric detection.

    PubMed

    George, Rani; Lobb, Michael; Haywood, Alison; Khan, Sohil; Hardy, Janet; Good, Phillip; Hennig, Stefanie; Norris, Ross

    2016-01-01

    Methadone is a potent lipophilic synthetic opioid that is effective in the treatment of cancer pain and perceived benefit in difficult pain control scenarios (especially in cases of neuropathic pain). The use of methadone in clinical practice is challenging however, due to the narrow therapeutic window and large inter- and intra-individual variability in therapeutic response. Quantitation of the enantiomers d- and l-methadone (d- and l-MTD) in plasma and saliva provides a basis for studying its pharmacokinetics in patients with cancer and for monitoring efficacy, toxicity and side-effects. This assay involves quantitation of the enantiomers of methadone using their respective deuterated internal standards, in plasma and saliva matrices with no impact of ion suppression in either matrix. The analytical recoveries of d- and l-MTD from the saliva collection devices (Salivette®) are optimised in this novel method with an accurate and simple extraction method employing dichloromethane. Optimal enantioselective separations were achieved using an α1-acid glycoprotein chiral stationary phase and triple quadrupole tandem mass spectrometer. Linearity was demonstrated over 0.05-1000µg/L for both enantiomers in plasma and in saliva with correlation coefficients greater than 0.998. The lower limit of quantitation (LLOQ) was determined to be 0.1µg/L in plasma and saliva for d- and l-MTD. Accuracy of the method ranges from 100% to 106% even at the LLOQ and total precision, expressed as the coefficient of variation, was between 0.2% and 4.4% for both analytes in both matrices. A simple one step extraction procedure resulted in recoveries greater than 95% for both analytes, at concentrations as low as 0.5µg/L, from the Salivette®. The validated method was applied successfully in 14 paired plasma and saliva samples obtained from adult patients with cancer pain receiving methadone. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Characterization, thermal stability studies, and analytical method development of Paromomycin for formulation development.

    PubMed

    Khan, Wahid; Kumar, Neeraj

    2011-06-01

    Paromomycin (PM) is an aminoglycoside antibiotic, first isolated in the 1950s, and approved in 2006 for treatment of visceral leishmaniasis. Although isolated six decades back, sufficient information essential for development of pharmaceutical formulation is not available for PM. The purpose of this paper was to determine thermal stability and development of new analytical method for formulation development of PM. PM was characterized by thermoanalytical (DSC, TGA, and HSM) and by spectroscopic (FTIR) techniques and these techniques were used to establish thermal stability of PM after heating PM at 100, 110, 120, and 130 °C for 24 h. Biological activity of these heated samples was also determined by microbiological assay. Subsequently, a simple, rapid and sensitive RP-HPLC method for quantitative determination of PM was developed using pre-column derivatization with 9-fluorenylmethyl chloroformate. The developed method was applied to estimate PM quantitatively in two parenteral dosage forms. PM was successfully characterized by various stated techniques. These techniques indicated stability of PM for heating up to 120 °C for 24 h, but when heated at 130 °C, PM is liable to degradation. This degradation is also observed in microbiological assay where PM lost ∼30% of its biological activity when heated at 130 °C for 24 h. New analytical method was developed for PM in the concentration range of 25-200 ng/ml with intra-day and inter-day variability of < 2%RSD. Characterization techniques were established and stability of PM was determined successfully. Developed analytical method was found sensitive, accurate, and precise for quantification of PM. Copyright © 2010 John Wiley & Sons, Ltd. Copyright © 2010 John Wiley & Sons, Ltd.

  14. Rapid and sensitive analytical method for monitoring of 12 organotin compounds in natural waters.

    PubMed

    Vahčič, Mitja; Milačič, Radmila; Sčančar, Janez

    2011-03-01

    A rapid analytical method for the simultaneous determination of 12 different organotin compounds (OTC): methyl-, butyl-, phenyl- and octyl-tins in natural water samples was developed. It comprises of in situ derivatisation (by using NaBEt4) of OTC in salty or fresh water sample matrix adjusted to pH 6 with Tris-citrate buffer, extraction of ethylated OTC into hexane, separation of OTC in organic phase on 15 m GC column and subsequent quantitative determination of separated OTC by ICP-MS. To optimise the pH of ethylation, phosphate, carbonate and Tris-citrate buffer were investigated alternatively to commonly applied sodium acetate - acetic acid buffer. The ethylation yields in Tris-citrate buffer were found to be better for TBT, MOcT and DOcT in comparison to commonly used acetate buffer. Iso-octane and hexane were examined as organic phase for extraction of ethylated OTC. The advantage of hexane was in its ability for quantitative determination of TMeT. GC column of 15 m in length was used for separation of studied OTC under the optimised separation conditions and its performances compared to 30 m column. The analytical method developed enables sensitive simultaneous determination of 12 different OTC and appreciably shortened analysis time in larger series of water samples. LOD's obtained for the newly developed method ranged from 0.05-0.06 ng Sn L-1 for methyl-, 0.11-0.45 ng Sn L-1 for butyl-, 0.11-0.16 ng Sn L-1 for phenyl-, and 0.07-0.10 ng Sn L-1 for octyl-tins. By applying the developed analytical method, marine water samples from the Northern Adriatic Sea containing mainly butyl- and methyl-tin species were analysed to confirm the proposed method's applicability.

  15. X-ray fluorescence analysis of K, Al and trace elements in chloroaluminate melts

    NASA Astrophysics Data System (ADS)

    Shibitko, A. O.; Abramov, A. V.; Denisov, E. I.; Lisienko, D. G.; Rebrin, O. I.; Bunkov, G. M.; Rychkov, V. N.

    2017-09-01

    Energy dispersive x-ray fluorescence spectrometry was applied to quantitative determination of K, Al, Cr, Fe and Ni in chloroaluminate melts. To implement the external standard calibration method, an unconventional way of samples preparation was suggested. A mixture of metal chlorides was melted in a quartz cell at 350-450 °C under a slightly excessive pressure of purified argon (99.999 %). The composition of the calibration samples (CSs) prepared was controlled by means of the inductively coupled plasma atomic emission spectrometry (ICP-AES). The optimal conditions for analytical lines excitation were determined, the analytes calibration curves were obtained. There was some influence of matrix effects in synthesized samples on the analytical signal of some elements. The CSs are to be stored in inert gas atmosphere. The precision, accuracy, and reproducibility factors of the quantitative chemical analysis were computed.

  16. An isocratic HPLC method for the simultaneous determination of cholesterol, cardiolipin, and DOPC in lyophilized lipids and liposomal formulations.

    PubMed

    Simonzadeh, Ninus

    2009-04-01

    Phospholipids, such as 1,2-dioleoyl-sn-glycero-3-phosphocholine (DOPC), and 1,1',2,2'-tetramyristoyl cardiolipin, along with cholesterol, form liposomes in aqueous media and have been investigated at NeoPharm (Lake Bluff, IL) as drug-delivery systems. To accurately assess the effectiveness of various formulations involving the use of aforementioned phospholipids and cholesterol, their quantitative determination is essential. An isocratic high-performance liquid chromatographic method for the simultaneous determination of cholesterol, cardiolipin, and DOPC in various pharmaceutical formulations containing the active drug substance has consequently been developed and is presented here. The current method utilizes an ASTEC-diol analytical column and is shown to be stability-indicating and free from interference from any of the formulation excipients, such as sucrose, sodium chloride, and sodium lactate. The analytes are detected using an evaporative light scattering detector (Alltech or Polymer Laboratories). The quantitation of each lipid component is performed using non-linear regression analysis. The retention characteristics of the analytes are examined as a function of eluent composition (e.g., pH, salt content, organic to aqueous phase ratio) and column temperature. The method was validated and was found to be sensitive, specific, rugged, and cost-effective. The current method provides enhanced chromatographic separation for lipid components as well as degradation products as compared to similar methods reported in the literature. It is also inherently simpler than other similar methods reported in the literature that typically use complex gradient elution.

  17. Comparison of three-way and four-way calibration for the real-time quantitative analysis of drug hydrolysis in complex dynamic samples by excitation-emission matrix fluorescence.

    PubMed

    Yin, Xiao-Li; Gu, Hui-Wen; Liu, Xiao-Lu; Zhang, Shan-Hui; Wu, Hai-Long

    2018-03-05

    Multiway calibration in combination with spectroscopic technique is an attractive tool for online or real-time monitoring of target analyte(s) in complex samples. However, how to choose a suitable multiway calibration method for the resolution of spectroscopic-kinetic data is a troubling problem in practical application. In this work, for the first time, three-way and four-way fluorescence-kinetic data arrays were generated during the real-time monitoring of the hydrolysis of irinotecan (CPT-11) in human plasma by excitation-emission matrix fluorescence. Alternating normalization-weighted error (ANWE) and alternating penalty trilinear decomposition (APTLD) were used as three-way calibration for the decomposition of the three-way kinetic data array, whereas alternating weighted residual constraint quadrilinear decomposition (AWRCQLD) and alternating penalty quadrilinear decomposition (APQLD) were applied as four-way calibration to the four-way kinetic data array. The quantitative results of the two kinds of calibration models were fully compared from the perspective of predicted real-time concentrations, spiked recoveries of initial concentration, and analytical figures of merit. The comparison study demonstrated that both three-way and four-way calibration models could achieve real-time quantitative analysis of the hydrolysis of CPT-11 in human plasma under certain conditions. However, it was also found that both of them possess some critical advantages and shortcomings during the process of dynamic analysis. The conclusions obtained in this paper can provide some helpful guidance for the reasonable selection of multiway calibration models to achieve the real-time quantitative analysis of target analyte(s) in complex dynamic systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Quantitative methods for compensation of matrix effects and self-absorption in Laser Induced Breakdown Spectroscopy signals of solids

    NASA Astrophysics Data System (ADS)

    Takahashi, Tomoko; Thornton, Blair

    2017-12-01

    This paper reviews methods to compensate for matrix effects and self-absorption during quantitative analysis of compositions of solids measured using Laser Induced Breakdown Spectroscopy (LIBS) and their applications to in-situ analysis. Methods to reduce matrix and self-absorption effects on calibration curves are first introduced. The conditions where calibration curves are applicable to quantification of compositions of solid samples and their limitations are discussed. While calibration-free LIBS (CF-LIBS), which corrects matrix effects theoretically based on the Boltzmann distribution law and Saha equation, has been applied in a number of studies, requirements need to be satisfied for the calculation of chemical compositions to be valid. Also, peaks of all elements contained in the target need to be detected, which is a bottleneck for in-situ analysis of unknown materials. Multivariate analysis techniques are gaining momentum in LIBS analysis. Among the available techniques, principal component regression (PCR) analysis and partial least squares (PLS) regression analysis, which can extract related information to compositions from all spectral data, are widely established methods and have been applied to various fields including in-situ applications in air and for planetary explorations. Artificial neural networks (ANNs), where non-linear effects can be modelled, have also been investigated as a quantitative method and their applications are introduced. The ability to make quantitative estimates based on LIBS signals is seen as a key element for the technique to gain wider acceptance as an analytical method, especially in in-situ applications. In order to accelerate this process, it is recommended that the accuracy should be described using common figures of merit which express the overall normalised accuracy, such as the normalised root mean square errors (NRMSEs), when comparing the accuracy obtained from different setups and analytical methods.

  19. An iterative method for near-field Fresnel region polychromatic phase contrast imaging

    NASA Astrophysics Data System (ADS)

    Carroll, Aidan J.; van Riessen, Grant A.; Balaur, Eugeniu; Dolbnya, Igor P.; Tran, Giang N.; Peele, Andrew G.

    2017-07-01

    We present an iterative method for polychromatic phase contrast imaging that is suitable for broadband illumination and which allows for the quantitative determination of the thickness of an object given the refractive index of the sample material. Experimental and simulation results suggest the iterative method provides comparable image quality and quantitative object thickness determination when compared to the analytical polychromatic transport of intensity and contrast transfer function methods. The ability of the iterative method to work over a wider range of experimental conditions means the iterative method is a suitable candidate for use with polychromatic illumination and may deliver more utility for laboratory-based x-ray sources, which typically have a broad spectrum.

  20. Minimizing thermal degradation in gas chromatographic quantitation of pentaerythritol tetranitrate.

    PubMed

    Lubrano, Adam L; Field, Christopher R; Newsome, G Asher; Rogers, Duane A; Giordano, Braden C; Johnson, Kevin J

    2015-05-15

    An analytical method for establishing calibration curves for the quantitation of pentaerythriol tetranitrate (PETN) from sorbent-filled thermal desorption tubes by gas chromatography with electron capture detection (TDS-GC-ECD) was developed. As PETN has been demonstrated to thermally degrade under typical GC instrument conditions, peaks corresponding to both PETN degradants and molecular PETN are observed. The retention time corresponding to intact PETN was verified by high-resolution mass spectrometry with a flowing atmospheric pressure afterglow (FAPA) ionization source, which enabled soft ionization of intact PETN eluting the GC and subsequent accurate-mass identification. The GC separation parameters were transferred to a conventional GC-ECD instrument where analytical method-induced PETN degradation was further characterized and minimized. A method calibration curve was established by direct liquid deposition of PETN standard solutions onto the glass frit at the head of sorbent-filled thermal desorption tubes. Two local, linear relationships between detector response and PETN concentration were observed, with a total dynamic range of 0.25-25ng. Published by Elsevier B.V.

  1. Picomolar quantitation of free sulfite in foods by means of [57Co]hydroxocobalamin and radiometric chromatography of [57Co]sulfitocobalamin. Method, applications and significance of coexisting sulfides.

    PubMed

    Beck, R A; Anes, J M; Savini, L M; Mateer, R A

    2000-06-09

    The concentration dependent reaction of sulfite with 57Co-labeled hydroxocobalamin (OH57CoCbl) to produce a sulfitocobalamin (SO(3)57CoCbl) adduct served as a quantification strategy for foodborne sulfite residues freely extracted into pH 5.2, 0.05 M acetate buffer. SO(3)57CoCbl was then resolved using SP-Sephadex C-25 gel chromatography and its radiometric detection allowed calculation of a standard logit plot from which unknown sulfite concentrations could be determined. The sulfite detection range was 6.0 nM-0.3 pM with respective relative standard deviations of 4.4-29.4% for 50-microl samples. Individual incidences of foodborne sulfite intolerances provoked by L-cysteine or sulfite additive use in bakery products, which remained undetected using conventional sulfite analytical methods, underscored the quantitative value of the method. The analytical significance and occurrences of detectable sulfides coexisting with foodborne sulfite residues was also addressed.

  2. Determining absolute protein numbers by quantitative fluorescence microscopy.

    PubMed

    Verdaasdonk, Jolien Suzanne; Lawrimore, Josh; Bloom, Kerry

    2014-01-01

    Biological questions are increasingly being addressed using a wide range of quantitative analytical tools to examine protein complex composition. Knowledge of the absolute number of proteins present provides insights into organization, function, and maintenance and is used in mathematical modeling of complex cellular dynamics. In this chapter, we outline and describe three microscopy-based methods for determining absolute protein numbers--fluorescence correlation spectroscopy, stepwise photobleaching, and ratiometric comparison of fluorescence intensity to known standards. In addition, we discuss the various fluorescently labeled proteins that have been used as standards for both stepwise photobleaching and ratiometric comparison analysis. A detailed procedure for determining absolute protein number by ratiometric comparison is outlined in the second half of this chapter. Counting proteins by quantitative microscopy is a relatively simple yet very powerful analytical tool that will increase our understanding of protein complex composition. © 2014 Elsevier Inc. All rights reserved.

  3. Development of an integrated laboratory system for the monitoring of cyanotoxins in surface and drinking waters.

    PubMed

    Triantis, Theodoros; Tsimeli, Katerina; Kaloudis, Triantafyllos; Thanassoulias, Nicholas; Lytras, Efthymios; Hiskia, Anastasia

    2010-05-01

    A system of analytical processes has been developed in order to serve as a cost-effective scheme for the monitoring of cyanobacterial toxins on a quantitative basis, in surface and drinking waters. Five cyclic peptide hepatotoxins, microcystin-LR, -RR, -YR, -LA and nodularin were chosen as the target compounds. Two different enzyme-linked immunosorbent assays (ELISA) were validated in order to serve as primary quantitative screening tools. Validation results showed that the ELISA methods are sufficiently specific and sensitive with limits of detection (LODs) around 0.1 microg/L, however, matrix effects should be considered, especially with surface water samples or bacterial mass methanolic extracts. A colorimetric protein phosphatase inhibition assay (PPIA) utilizing protein phosphatase 2A and p-nitrophenyl phosphate as substrate, was applied in microplate format in order to serve as a quantitative screening method for the detection of the toxic activity associated with cyclic peptide hepatotoxins, at concentration levels >0.2 microg/L of MC-LR equivalents. A fast HPLC/PDA method has been developed for the determination of microcystins, by using a short, 50mm C18 column, with 1.8 microm particle size. Using this method a 10-fold reduction of sample run time was achieved and sufficient separation of microcystins was accomplished in less than 3 min. Finally, the analytical system includes an LC/MS/MS method that was developed for the determination of the 5 target compounds after SPE extraction. The method achieves extremely low limits of detection (<0.02 microg/L), in both surface and drinking waters and it is used for identification and verification purposes as well as for determinations at the ppt level. An analytical protocol that includes the above methods has been designed and validated through the analysis of a number of real samples. Copyright 2009 Elsevier Ltd. All rights reserved.

  4. From observational to analytical morphology of the stratum corneum: progress avoiding hazardous animal and human testings

    PubMed Central

    Piérard, Gérald E; Courtois, Justine; Ritacco, Caroline; Humbert, Philippe; Fanian, Ferial; Piérard-Franchimont, Claudine

    2015-01-01

    Background In cosmetic science, noninvasive sampling of the upper part of the stratum corneum is conveniently performed using strippings with adhesive-coated discs (SACD) and cyanoacrylate skin surface strippings (CSSSs). Methods Under controlled conditions, it is possible to scrutinize SACD and CSSS with objectivity using appropriate methods of analytical morphology. These procedures apply to a series of clinical conditions including xerosis grading, comedometry, corneodynamics, corneomelametry, corneosurfametry, corneoxenometry, and dandruff assessment. Results With any of the analytical evaluations, SACD and CSSS provide specific salient information that is useful in the field of cosmetology. In particular, both methods appear valuable and complementary in assessing the human skin compatibility of personal skincare products. Conclusion A set of quantitative analytical methods applicable to the minimally invasive and low-cost SACD and CSSS procedures allow for a sound assessment of cosmetic effects on the stratum corneum. Under regular conditions, both methods are painless and do not induce adverse events. Globally, CSSS appears more precise and informative than the regular SACD stripping. PMID:25767402

  5. Electrodialytic in-line preconcentration for ionic solute analysis.

    PubMed

    Ohira, Shin-Ichi; Yamasaki, Takayuki; Koda, Takumi; Kodama, Yuko; Toda, Kei

    2018-04-01

    Preconcentration is an effective way to improve analytical sensitivity. Many types of methods are used for enrichment of ionic solute analytes. However, current methods are batchwise and include procedures such as trapping and elution. In this manuscript, we propose in-line electrodialytic enrichment of ionic solutes. The method can enrich ionic solutes within seconds by quantitative transfer of analytes from the sample solution to the acceptor solution under an electric field. Because of quantitative ion transfer, the enrichment factor (the ratio of the concentration in the sample and to that in the obtained acceptor solution) only depends on the flow rate ratio of the sample solution to the acceptor solution. The ratios of the concentrations and flow rates are equal for ratios up to 70, 20, and 70 for the tested ionic solutes of inorganic cations, inorganic anions, and heavy metal ions, respectively. The sensitivity of ionic solute determinations is also improved based on the enrichment factor. The method can also simultaneously achieve matrix isolation and enrichment. The method was successively applied to determine the concentrations of trace amounts of chloroacetic acids in tap water. The regulated concentration levels cannot be determined by conventional high-performance liquid chromatography with ultraviolet detection (HPLC-UV) without enrichment. However, enrichment with the present method is effective for determination of tap water quality by improving the limits of detection of HPLC-UV. The standard addition test with real tap water samples shows good recoveries (94.9-109.6%). Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Quantitation of N,N-dimethyltryptamine and harmala alkaloids in human plasma after oral dosing with ayahuasca.

    PubMed

    Callaway, J C; Raymon, L P; Hearn, W L; McKenna, D J; Grob, C S; Brito, G S; Mash, D C

    1996-10-01

    Harmine, harmaline, tetrahydroharmine (THH), and N,N-dimethyltryptamine (DMT) were quantitated in plasma from 15 healthy male volunteers after the ingestion of ayahuasca, a beverage that has been used for religious purposes in Brazil since pre-Columbian times. A growing awareness of the interest in this ancient shamanistic practice in modern urban cultures and the widespread popular dissemination of the inebriant effects and type and sources of the plant admixtures used to prepare the beverage have provided additional impetus for this study. The three harmala alkaloids were quantitated from protein-precipitated plasma by high-performance liquid chromatography using fluorescence detection. Recovery from blank human plasma was quantitative, and the limit of quantitation (LOQ) was below 2 ng/mL of plasma for each of the harmala alkaloids. Standard concentrations ranged from 10 to 250 ng/mL for harmine and THH and from 1.0 to 25.0 ng/mL for harmaline, respectively. Linearity was observed for harmine, harmaline, and THH within these respective ranges. The highest concentrations of harmala alkaloids in human plasma were found to be 222.3 ng/mL for harmine, 134.5 ng/mL for THH, and 9.4 ng/mL for harmaline. DMT was quantitated by gas chromatography using nitrogen-phosphorus detection after liquid-liquid extraction with diphenhydramine as an internal standard. DMT recovery was quantitative, and the limit of detection and LOQ were 0.5 and 5 ng/mL, respectively. Linearity for DMT was observed from 5 to 1000 ng/mL. The one-step extraction method for DMT and the protein precipitation method for the three harmala alkaloids afford rapid, sensitive, and quantitative analyses of these alkaloids with minimal analyte loss. The analytical methods also may be applicable to other matrices, including whole blood and urine samples and homogenized tissue specimens. These are the first reported observations of DMT and harmala alkaloids in plasma after ritual ingestion of ayahuasca.

  7. Analytical techniques and method validation for the measurement of selected semivolatile and nonvolatile organofluorochemicals in air.

    PubMed

    Reagen, William K; Lindstrom, Kent R; Thompson, Kathy L; Flaherty, John M

    2004-09-01

    The widespread use of semi- and nonvolatile organofluorochemicals in industrial facilities, concern about their persistence, and relatively recent advancements in liquid chromatography/mass spectrometry (LC/MS) technology have led to the development of new analytical methods to assess potential worker exposure to airborne organofluorochemicals. Techniques were evaluated for the determination of 19 organofluorochemicals and for total fluorine in ambient air samples. Due to the potential biphasic nature of most of these fluorochemicals when airborne, Occupational Safety and Health Administration (OSHA) versatile sampler (OVS) tubes were used to simultaneously trap fluorochemical particulates and vapors from workplace air. Analytical methods were developed for OVS air samples to quantitatively analyze for total fluorine using oxygen bomb combustion/ion selective electrode and for 17 organofluorochemicals using LC/MS and gas chromatography/mass spectrometry (GC/MS). The experimental design for this validation was based on the National Institute of Occupational Safety and Health (NIOSH) Guidelines for Air Sampling and Analytical Method Development and Evaluation, with some revisions of the experimental design. The study design incorporated experiments to determine analytical recovery and stability, sampler capacity, the effect of some environmental parameters on recoveries, storage stability, limits of detection, precision, and accuracy. Fluorochemical mixtures were spiked onto each OVS tube over a range of 0.06-6 microg for each of 12 compounds analyzed by LC/MS and 0.3-30 microg for 5 compounds analyzed by GC/MS. These ranges allowed reliable quantitation at 0.001-0.1 mg/m3 in general for LC/MS analytes and 0.005-0.5 mg/m3 for GC/MS analytes when 60 L of air are sampled. The organofluorochemical exposure guideline (EG) is currently 0.1 mg/m3 for many analytes, with one exception being ammonium perfluorooctanoate (EG is 0.01 mg/m3). Total fluorine results may be used to determine if the individual compounds quantified provide a suitable mass balance of total airborne organofluorochemicals based on known fluorine content. Improvements in precision and/or recovery as well as some additional testing would be needed to meet all NIOSH validation criteria. This study provided valuable information about the accuracy of this method for organofluorochemical exposure assessment.

  8. The analytical calibration in (bio)imaging/mapping of the metallic elements in biological samples--definitions, nomenclature and strategies: state of the art.

    PubMed

    Jurowski, Kamil; Buszewski, Bogusław; Piekoszewski, Wojciech

    2015-01-01

    Nowadays, studies related to the distribution of metallic elements in biological samples are one of the most important issues. There are many articles dedicated to specific analytical atomic spectrometry techniques used for mapping/(bio)imaging the metallic elements in various kinds of biological samples. However, in such literature, there is a lack of articles dedicated to reviewing calibration strategies, and their problems, nomenclature, definitions, ways and methods used to obtain quantitative distribution maps. The aim of this article was to characterize the analytical calibration in the (bio)imaging/mapping of the metallic elements in biological samples including (1) nomenclature; (2) definitions, and (3) selected and sophisticated, examples of calibration strategies with analytical calibration procedures applied in the different analytical methods currently used to study an element's distribution in biological samples/materials such as LA ICP-MS, SIMS, EDS, XRF and others. The main emphasis was placed on the procedures and methodology of the analytical calibration strategy. Additionally, the aim of this work is to systematize the nomenclature for the calibration terms: analytical calibration, analytical calibration method, analytical calibration procedure and analytical calibration strategy. The authors also want to popularize the division of calibration methods that are different than those hitherto used. This article is the first work in literature that refers to and emphasizes many different and complex aspects of analytical calibration problems in studies related to (bio)imaging/mapping metallic elements in different kinds of biological samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Using FTIR-ATR Spectroscopy to Teach the Internal Standard Method

    ERIC Educational Resources Information Center

    Bellamy, Michael K.

    2010-01-01

    The internal standard method is widely applied in quantitative analyses. However, most analytical chemistry textbooks either omit this topic or only provide examples of a single-point internal standardization. An experiment designed to teach students how to prepare an internal standard calibration curve is described. The experiment is a modified…

  10. Development, Validation, and Interlaboratory Evaluation of a Quantitative Multiplexing Method To Assess Levels of Ten Endogenous Allergens in Soybean Seed and Its Application to Field Trials Spanning Three Growing Seasons.

    PubMed

    Hill, Ryan C; Oman, Trent J; Wang, Xiujuan; Shan, Guomin; Schafer, Barry; Herman, Rod A; Tobias, Rowel; Shippar, Jeff; Malayappan, Bhaskar; Sheng, Li; Xu, Austin; Bradshaw, Jason

    2017-07-12

    As part of the regulatory approval process in Europe, comparison of endogenous soybean allergen levels between genetically engineered (GE) and non-GE plants has been requested. A quantitative multiplex analytical method using tandem mass spectrometry was developed and validated to measure 10 potential soybean allergens from soybean seed. The analytical method was implemented at six laboratories to demonstrate the robustness of the method and further applied to three soybean field studies across multiple growing seasons (including 21 non-GE soybean varieties) to assess the natural variation of allergen levels. The results show environmental factors contribute more than genetic factors to the large variation in allergen abundance (2- to 50-fold between environmental replicates) as well as a large contribution of Gly m 5 and Gly m 6 to the total allergen profile, calling into question the scientific rational for measurement of endogenous allergen levels between GE and non-GE varieties in the safety assessment.

  11. Cell bioprocessing in space - Applications of analytical cytology

    NASA Technical Reports Server (NTRS)

    Todd, P.; Hymer, W. C.; Goolsby, C. L.; Hatfield, J. M.; Morrison, D. R.

    1988-01-01

    Cell bioprocessing experiments in space are reviewed and the development of on-board cell analytical cytology techniques that can serve such experiments is discussed. Methods and results of experiments involving the cultivation and separation of eukaryotic cells in space are presented. It is suggested that an advanced cytometer should be developed for the quantitative analysis of large numbers of specimens of suspended eukaryotic cells and bioparticles in experiments on the Space Station.

  12. Simultaneous determination of celecoxib, hydroxycelecoxib, and carboxycelecoxib in human plasma using gradient reversed-phase liquid chromatography with ultraviolet absorbance detection.

    PubMed

    Störmer, Elke; Bauer, Steffen; Kirchheiner, Julia; Brockmöller, Jürgen; Roots, Ivar

    2003-01-05

    A new HPLC method for the simultaneous determination of celecoxib, carboxycelecoxib and hydroxycelecoxib in human plasma samples has been developed. Following a solid-phase extraction procedure, the samples were separated by gradient reversed-phase HLPC (C(18)) and quantified using UV detection at 254 nm. The method was linear over the concentration range 10-500 ng/ml. The intra-assay variability for the three analytes ranged from 4.0 to 12.6% and the inter-assay variability from 4.9 to 14.2%. The achieved limits of quantitation (LOQ) of 10 ng/ml for each analyte allowed the determination of the pharmacokinetic parameters of the analytes after administration of 100 mg celecoxib.

  13. Simple and rapid method for isolation and quantitation of polyhydroxyalkanoate by SDS-sonication treatment.

    PubMed

    Arikawa, Hisashi; Sato, Shunsuke; Fujiki, Tetsuya; Matsumoto, Keiji

    2017-08-01

    We developed a new method for isolation and quantitation of polyhydroxyalkanoate (PHA) from culture broth. In this method, the cells were sonicated in sodium dodecyl sulfate (SDS) solution and centrifuged to recover PHA. The recovered PHA was rinsed with deionized water and ethanol, and then weighed after drying. Hazardous chemicals such as chloroform, methanol, and sulfuric acid were not used, and no expensive analytical instruments were needed. We applied this method to Cupriavidus necator culture broths that included various amounts of poly(3-hydroxybutyrate) (PHB) or poly(3-hydroxybutyrate-co-3-hydroxyhexanoate) (PHBHHx) from flasks and jar fermentors. The quantitation by this method was practical for use with a wide range of production amounts and PHA monomer compositions compared to the conventional whole-cell methanolysis method with gas chromatographic analysis, and besides, the recovered PHAs were adequately pure (≥96% purity). Therefore, this new method would be valuable not only for quantitation of PHA but also for preparation of samples to characterize their mechanical properties. Copyright © 2017 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  14. Assessing the impact of natural policy experiments on socioeconomic inequalities in health: how to apply commonly used quantitative analytical methods?

    PubMed

    Hu, Yannan; van Lenthe, Frank J; Hoffmann, Rasmus; van Hedel, Karen; Mackenbach, Johan P

    2017-04-20

    The scientific evidence-base for policies to tackle health inequalities is limited. Natural policy experiments (NPE) have drawn increasing attention as a means to evaluating the effects of policies on health. Several analytical methods can be used to evaluate the outcomes of NPEs in terms of average population health, but it is unclear whether they can also be used to assess the outcomes of NPEs in terms of health inequalities. The aim of this study therefore was to assess whether, and to demonstrate how, a number of commonly used analytical methods for the evaluation of NPEs can be applied to quantify the effect of policies on health inequalities. We identified seven quantitative analytical methods for the evaluation of NPEs: regression adjustment, propensity score matching, difference-in-differences analysis, fixed effects analysis, instrumental variable analysis, regression discontinuity and interrupted time-series. We assessed whether these methods can be used to quantify the effect of policies on the magnitude of health inequalities either by conducting a stratified analysis or by including an interaction term, and illustrated both approaches in a fictitious numerical example. All seven methods can be used to quantify the equity impact of policies on absolute and relative inequalities in health by conducting an analysis stratified by socioeconomic position, and all but one (propensity score matching) can be used to quantify equity impacts by inclusion of an interaction term between socioeconomic position and policy exposure. Methods commonly used in economics and econometrics for the evaluation of NPEs can also be applied to assess the equity impact of policies, and our illustrations provide guidance on how to do this appropriately. The low external validity of results from instrumental variable analysis and regression discontinuity makes these methods less desirable for assessing policy effects on population-level health inequalities. Increased use of the methods in social epidemiology will help to build an evidence base to support policy making in the area of health inequalities.

  15. Quantitative determination of triterpene saponins and alkenated-phenolics from Labisia pumila using LC-UV/ELSD method and confirmation by LC-ESI-TOF

    USDA-ARS?s Scientific Manuscript database

    This study describes the first analytical method for the determination of saponins and alkenated-phenolics from the leaves, leaves/stems and roots of Labisia pumila using a HPLC-UV-ELSD method. The separation was achieved using a reversed phase column, PDA and ELS detection, and a water/acetonitrile...

  16. Quantitative determination of triperpene saponins and alkenated-phenolics from Labisia pumila using LC-UV/ELSD method and confirmation by LC-ESI-TOF

    USDA-ARS?s Scientific Manuscript database

    This study describes the first analytical method for the determination of saponins and alkenated-phenolics from the leaves, leaves/stems and roots of Labisia pumila using a HPLC-UV-ELSD method. The separation was achieved using a reversed phase column, PDA and ELS detection, and a water/acetonitrile...

  17. Determination of Aluminum in Dialysis Concentrates by Atomic Absorption Spectrometry after Coprecipitation with Lanthanum Phosphate.

    PubMed

    Selvi, Emine Kılıçkaya; Şahin, Uğur; Şahan, Serkan

    2017-01-01

    This method was developed for the determination of trace amounts of aluminum(III) in dialysis concentrates using atomic absorption spectrometry after coprecipitation with lanthanum phosphate. The analytical parameters that influenced the quantitative coprecipitation of analyte including amount of lanthanum, amount of phosfate, pH and duration time were optimized. The % recoveries of the analyte ion were in the range of 95-105 % with limit of detection (3s) of 0.5 µg l -1 . Preconcentration factor was found as 1000 and Relative Standard Deviation (RSD) % value obtained from model solutions was 2.5% for 0.02 mg L -1 . The accuracy of the method was evaluated with standard reference material (CWW-TMD Waste Water). The method was also applied to most concentrated acidic and basic dialysis concentrates with satisfactory results.

  18. Quantitation of sugar content in pyrolysis liquids after acid hydrolysis using high-performance liquid chromatography without neutralization.

    PubMed

    Johnston, Patrick A; Brown, Robert C

    2014-08-13

    A rapid method for the quantitation of total sugars in pyrolysis liquids using high-performance liquid chromatography (HPLC) was developed. The method avoids the tedious and time-consuming sample preparation required by current analytical methods. It is possible to directly analyze hydrolyzed pyrolysis liquids, bypassing the neutralization step usually required in determination of total sugars. A comparison with traditional methods was used to determine the validity of the results. The calibration curve coefficient of determination on all standard compounds was >0.999 using a refractive index detector. The relative standard deviation for the new method was 1.13%. The spiked sugar recoveries on the pyrolysis liquid samples were between 104 and 105%. The research demonstrates that it is possible to obtain excellent accuracy and efficiency using HPLC to quantitate glucose after acid hydrolysis of polymeric and oligomeric sugars found in fast pyrolysis bio-oils without neutralization.

  19. High-throughput method for the quantitation of metabolites and co-factors from homocysteine-methionine cycle for nutritional status assessment.

    PubMed

    Da Silva, Laeticia; Collino, Sebastiano; Cominetti, Ornella; Martin, Francois-Pierre; Montoliu, Ivan; Moreno, Sergio Oller; Corthesy, John; Kaput, Jim; Kussmann, Martin; Monteiro, Jacqueline Pontes; Guiraud, Seu Ping

    2016-09-01

    There is increasing interest in the profiling and quantitation of methionine pathway metabolites for health management research. Currently, several analytical approaches are required to cover metabolites and co-factors. We report the development and the validation of a method for the simultaneous detection and quantitation of 13 metabolites in red blood cells. The method, validated in a cohort of healthy human volunteers, shows a high level of accuracy and reproducibility. This high-throughput protocol provides a robust coverage of central metabolites and co-factors in one single analysis and in a high-throughput fashion. In large-scale clinical settings, the use of such an approach will significantly advance the field of nutritional research in health and disease.

  20. A Review of Analytical Methods for p-Coumaric Acid in Plant-Based Products, Beverages, and Biological Matrices.

    PubMed

    Ferreira, Paula Scanavez; Victorelli, Francesca Damiani; Fonseca-Santos, Bruno; Chorilli, Marlus

    2018-05-14

    p-Coumaric acid (p-CA), also known as 4-hydroxycinnamic acid, is a phenolic acid, which has been widely studied due to its beneficial effects against several diseases and its wide distribution in the plant kingdom. This phenolic compound can be found in the free form or conjugated with other molecules; therefore, its bioavailability and the pathways via which it is metabolized change according to its chemical structure. p-CA has potential pharmacological effects because it has high free radical scavenging, anti-inflammatory, antineoplastic, and antimicrobial activities, among other biological properties. It is therefore essential to choose the most appropriate and effective analytical method for qualitative and quantitative determination of p-CA in different matrices, such as plasma, urine, plant extracts, and drug delivery systems. The most-reported analytical method for this purpose is high-performance liquid chromatography, which is mostly coupled with some type of detectors, such as UV/Vis detector. However, other analytical techniques are also used to evaluate this compound. This review presents a summary of p-CA in terms of its chemical and pharmacokinetic properties, pharmacological effects, drug delivery systems, and the analytical methods described in the literature that are suitable for its quantification.

  1. LipidQC: Method Validation Tool for Visual Comparison to SRM 1950 Using NIST Interlaboratory Comparison Exercise Lipid Consensus Mean Estimate Values.

    PubMed

    Ulmer, Candice Z; Ragland, Jared M; Koelmel, Jeremy P; Heckert, Alan; Jones, Christina M; Garrett, Timothy J; Yost, Richard A; Bowden, John A

    2017-12-19

    As advances in analytical separation techniques, mass spectrometry instrumentation, and data processing platforms continue to spur growth in the lipidomics field, more structurally unique lipid species are detected and annotated. The lipidomics community is in need of benchmark reference values to assess the validity of various lipidomics workflows in providing accurate quantitative measurements across the diverse lipidome. LipidQC addresses the harmonization challenge in lipid quantitation by providing a semiautomated process, independent of analytical platform, for visual comparison of experimental results of National Institute of Standards and Technology Standard Reference Material (SRM) 1950, "Metabolites in Frozen Human Plasma", against benchmark consensus mean concentrations derived from the NIST Lipidomics Interlaboratory Comparison Exercise.

  2. Evaluation of the analytical variability of dipstick protein pads in canine urine.

    PubMed

    Giraldi, Marco; Paltrinieri, Saverio; Zatelli, Andrea

    2018-06-01

    The dipstick is a first-line and inexpensive test that can exclude the presence of proteinuria in dogs. However, no information is available about the analytical variability of canine urine dipstick analysis. The aim of this study was to assess the analytical variability in 2 dipsticks and the inter-operator variability in dipstick interpretation. Canine urine supernatants (n = 174) were analyzed with 2 commercially available dipsticks. Two observers evaluated each result blinded to the other observer and to the results of the other dipstick. Intra- and inter-assay variability was assessed in 5 samples (corresponding to the 5 different semi-quantitative results) tested 10 consecutive times over 5 consecutive days. The agreement between observers and between dipsticks was evaluated with Cohen's k test. Intra-assay repeatability was good (≤3/10 errors), whereas inter-assay variability was higher (from 1/5 to 4/5 discordant results). The concordance between the operators (k = 0.68 and 0.79 for the 2 dipsticks) and that of the dipsticks (k = 0.66 and 0.74 for the 2 operators) was good. However, 1 observer and 1 dipstick overestimated the results compared with the second observer or dipstick. In any case, discordant results accounted for a single unit of the semi-quantitative scale. As for any other method, analytic variability may affect the semi-quantitation of urinary proteins when using the dipstick method. Subjective interpretation of the pad and, to a lesser extent, intrinsic staining properties of the pads could affect the results. Further studies are warranted to evaluate the effect of this variability on clinical decisions. © 2018 American Society for Veterinary Clinical Pathology.

  3. Simultaneous determination of seven coumarins by UPLC-MS/MS: Application to a comparative pharmacokinetic study in normal and arthritic rats after oral administration of Huo Luo Xiao Ling Dan or single-herb extract.

    PubMed

    Wu, Yun; Wang, Fenrong; Ai, Yu; Ma, Wen; Bian, Qiaoxia; Lee, David Y-W; Dai, Ronghua

    2015-06-01

    A simple, sensitive and reliable ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method has been developed and validated for simultaneous quantitation of seven coumarins, the bio-active ingredients of Huo Luo Xiao Ling Dan (HLXLD), in rat plasma. The liquid-liquid extraction method with ether-dichloromethane (2:1, v/v) was used to prepare the plasma samples. Analytes and internal standard (IS) of bifendate were separated on a Shim-pack XR-ODS column (75mm×3.0mm, 2.2μm particles) using gradient elution with the mobile phase consisting of methanol and 0.05% formic acid in water at a flow rate of 0.4mL/min. Detection was performed on a triple quadrupole (TQ) tandem mass spectrometry equipped with an electrospray ionization source in the positive ionization and multiple reaction monitoring (MRM) mode. The lower limits of quantitation (LLOQ) were 0.03-0.25ng/mL for all the analytes. Intra- and inter-day precision and accuracy of the seven analytes were well within acceptance criteria (15%). The matrix effect and the mean extraction recoveries of the analytes and IS from rat plasma were all within satisfaction. The validated method has been successfully applied to compare pharmacokinetic profiles of the seven active ingredients in rat plasma between normal and arthritic rats after oral administration of HLXLD, Angelica pubescens extract and Notopterygium incisum extract, respectively. Results showed that there were remarkable differences in pharmacokinetic properties of the analytes among the different groups. Copyright © 2015. Published by Elsevier B.V.

  4. Chemometric resolution of fully overlapped CE peaks: quantitation of carbamazepine in human serum in the presence of several interferences.

    PubMed

    Vera-Candioti, Luciana; Culzoni, María J; Olivieri, Alejandro C; Goicoechea, Héctor C

    2008-11-01

    Drug monitoring in serum samples was performed using second-order data generated by CE-DAD, processed with a suitable chemometric strategy. Carbamazepine could be accurately quantitated in the presence of its main metabolite (carbamazepine epoxide), other therapeutic drugs (lamotrigine, phenobarbital, phenytoin, phenylephrine, ibuprofen, acetaminophen, theophylline, caffeine, acetyl salicylic acid), and additional serum endogenous components. The analytical strategy consisted of the following steps: (i) serum sample clean-up to remove matrix interferences, (ii) data pre-processing, in order to reduce the background and to correct for electrophoretic time shifts, and (iii) resolution of fully overlapped CE peaks (corresponding to carbamazepine, its metabolite, lamotrigine and unexpected serum components) by the well-known multivariate curve resolution-alternating least squares algorithm, which extracts quantitative information that can be uniquely ascribed to the analyte of interest. The analyte concentration in serum samples ranged from 2.00 to 8.00 mg/L. Mean recoveries were 102.6% (s=7.7) for binary samples, and 94.8% (s=13.5) for spiked serum samples, while CV (%)=4.0 was computed for five replicate, indicative of the acceptable accuracy and precision of the proposed method.

  5. Advances in multiplexed MRM-based protein biomarker quantitation toward clinical utility.

    PubMed

    Percy, Andrew J; Chambers, Andrew G; Yang, Juncong; Hardie, Darryl B; Borchers, Christoph H

    2014-05-01

    Accurate and rapid protein quantitation is essential for screening biomarkers for disease stratification and monitoring, and to validate the hundreds of putative markers in human biofluids, including blood plasma. An analytical method that utilizes stable isotope-labeled standard (SIS) peptides and selected/multiple reaction monitoring-mass spectrometry (SRM/MRM-MS) has emerged as a promising technique for determining protein concentrations. This targeted approach has analytical merit, but its true potential (in terms of sensitivity and multiplexing) has yet to be realized. Described herein is a method that extends the multiplexing ability of the MRM method to enable the quantitation 142 high-to-moderate abundance proteins (from 31mg/mL to 44ng/mL) in undepleted and non-enriched human plasma in a single run. The proteins have been reported to be associated to a wide variety of non-communicable diseases (NCDs), from cardiovascular disease (CVD) to diabetes. The concentrations of these proteins in human plasma are inferred from interference-free peptides functioning as molecular surrogates (2 peptides per protein, on average). A revised data analysis strategy, involving the linear regression equation of normal control plasma, has been instituted to enable the facile application to patient samples, as demonstrated in separate nutrigenomics and CVD studies. The exceptional robustness of the LC/MS platform and the quantitative method, as well as its high throughput, makes the assay suitable for application to patient samples for the verification of a condensed or complete protein panel. This article is part of a Special Issue entitled: Biomarkers: A Proteomic Challenge. © 2013.

  6. [Development and validation of event-specific quantitative PCR method for genetically modified maize LY038].

    PubMed

    Mano, Junichi; Masubuchi, Tomoko; Hatano, Shuko; Futo, Satoshi; Koiwa, Tomohiro; Minegishi, Yasutaka; Noguchi, Akio; Kondo, Kazunari; Akiyama, Hiroshi; Teshima, Reiko; Kurashima, Takeyo; Takabatake, Reona; Kitta, Kazumi

    2013-01-01

    In this article, we report a novel real-time PCR-based analytical method for quantitation of the GM maize event LY038. We designed LY038-specific and maize endogenous reference DNA-specific PCR amplifications. After confirming the specificity and linearity of the LY038-specific PCR amplification, we determined the conversion factor required to calculate the weight-based content of GM organism (GMO) in a multilaboratory evaluation. Finally, in order to validate the developed method, an interlaboratory collaborative trial according to the internationally harmonized guidelines was performed with blind DNA samples containing LY038 at the mixing levels of 0, 0.5, 1.0, 5.0 and 10.0%. The precision of the method was evaluated as the RSD of reproducibility (RSDR), and the values obtained were all less than 25%. The limit of quantitation of the method was judged to be 0.5% based on the definition of ISO 24276 guideline. The results from the collaborative trial suggested that the developed quantitative method would be suitable for practical testing of LY038 maize.

  7. Simple and cost-effective liquid chromatography-mass spectrometry method to measure dabrafenib quantitatively and six metabolites semi-quantitatively in human plasma.

    PubMed

    Vikingsson, Svante; Dahlberg, Jan-Olof; Hansson, Johan; Höiom, Veronica; Gréen, Henrik

    2017-06-01

    Dabrafenib is an inhibitor of BRAF V600E used for treating metastatic melanoma but a majority of patients experience adverse effects. Methods to measure the levels of dabrafenib and major metabolites during treatment are needed to allow development of individualized dosing strategies to reduce the burden of such adverse events. In this study, an LC-MS/MS method capable of measuring dabrafenib quantitatively and six metabolites semi-quantitatively is presented. The method is fully validated with regard to dabrafenib in human plasma in the range 5-5000 ng/mL. The analytes were separated on a C18 column after protein precipitation and detected in positive electrospray ionization mode using a Xevo TQ triple quadrupole mass spectrometer. As no commercial reference standards are available, the calibration curve of dabrafenib was used for semi-quantification of dabrafenib metabolites. Compared to earlier methods the presented method represents a simpler and more cost-effective approach suitable for clinical studies. Graphical abstract Combined multi reaction monitoring transitions of dabrafenib and metabolites in a typical case sample.

  8. Analytical Methodologies for the Determination of Endocrine Disrupting Compounds in Biological and Environmental Samples

    PubMed Central

    Sosa-Ferrera, Zoraida; Mahugo-Santana, Cristina; Santana-Rodríguez, José Juan

    2013-01-01

    Endocrine-disruptor compounds (EDCs) can mimic natural hormones and produce adverse effects in the endocrine functions by interacting with estrogen receptors. EDCs include both natural and synthetic chemicals, such as hormones, personal care products, surfactants, and flame retardants, among others. EDCs are characterised by their ubiquitous presence at trace-level concentrations and their wide diversity. Since the discovery of the adverse effects of these pollutants on wildlife and human health, analytical methods have been developed for their qualitative and quantitative determination. In particular, mass-based analytical methods show excellent sensitivity and precision for their quantification. This paper reviews recently published analytical methodologies for the sample preparation and for the determination of these compounds in different environmental and biological matrices by liquid chromatography coupled with mass spectrometry. The various sample preparation techniques are compared and discussed. In addition, recent developments and advances in this field are presented. PMID:23738329

  9. Analytical Validation of Quantitative Real-Time PCR Methods for Quantification of Trypanosoma cruzi DNA in Blood Samples from Chagas Disease Patients

    PubMed Central

    Ramírez, Juan Carlos; Cura, Carolina Inés; Moreira, Otacilio da Cruz; Lages-Silva, Eliane; Juiz, Natalia; Velázquez, Elsa; Ramírez, Juan David; Alberti, Anahí; Pavia, Paula; Flores-Chávez, María Delmans; Muñoz-Calderón, Arturo; Pérez-Morales, Deyanira; Santalla, José; Guedes, Paulo Marcos da Matta; Peneau, Julie; Marcet, Paula; Padilla, Carlos; Cruz-Robles, David; Valencia, Edward; Crisante, Gladys Elena; Greif, Gonzalo; Zulantay, Inés; Costales, Jaime Alfredo; Alvarez-Martínez, Miriam; Martínez, Norma Edith; Villarroel, Rodrigo; Villarroel, Sandro; Sánchez, Zunilda; Bisio, Margarita; Parrado, Rudy; Galvão, Lúcia Maria da Cunha; da Câmara, Antonia Cláudia Jácome; Espinoza, Bertha; de Noya, Belkisyole Alarcón; Puerta, Concepción; Riarte, Adelina; Diosque, Patricio; Sosa-Estani, Sergio; Guhl, Felipe; Ribeiro, Isabela; Aznar, Christine; Britto, Constança; Yadón, Zaida Estela; Schijman, Alejandro G.

    2015-01-01

    An international study was performed by 26 experienced PCR laboratories from 14 countries to assess the performance of duplex quantitative real-time PCR (qPCR) strategies on the basis of TaqMan probes for detection and quantification of parasitic loads in peripheral blood samples from Chagas disease patients. Two methods were studied: Satellite DNA (SatDNA) qPCR and kinetoplastid DNA (kDNA) qPCR. Both methods included an internal amplification control. Reportable range, analytical sensitivity, limits of detection and quantification, and precision were estimated according to international guidelines. In addition, inclusivity and exclusivity were estimated with DNA from stocks representing the different Trypanosoma cruzi discrete typing units and Trypanosoma rangeli and Leishmania spp. Both methods were challenged against 156 blood samples provided by the participant laboratories, including samples from acute and chronic patients with varied clinical findings, infected by oral route or vectorial transmission. kDNA qPCR showed better analytical sensitivity than SatDNA qPCR with limits of detection of 0.23 and 0.70 parasite equivalents/mL, respectively. Analyses of clinical samples revealed a high concordance in terms of sensitivity and parasitic loads determined by both SatDNA and kDNA qPCRs. This effort is a major step toward international validation of qPCR methods for the quantification of T. cruzi DNA in human blood samples, aiming to provide an accurate surrogate biomarker for diagnosis and treatment monitoring for patients with Chagas disease. PMID:26320872

  10. Gold Nanoparticles as a Direct and Rapid Sensor for Sensitive Analytical Detection of Biogenic Amines

    NASA Astrophysics Data System (ADS)

    El-Nour, K. M. A.; Salam, E. T. A.; Soliman, H. M.; Orabi, A. S.

    2017-03-01

    A new optical sensor was developed for rapid screening with high sensitivity for the existence of biogenic amines (BAs) in poultry meat samples. Gold nanoparticles (GNPs) with particle size 11-19 nm function as a fast and sensitive biosensor for detection of histamine resulting from bacterial decarboxylation of histidine as a spoilage marker for stored poultry meat. Upon reaction with histamine, the red color of the GNPs converted into deep blue. The appearance of blue color favorably coincides with the concentration of BAs that can induce symptoms of poisoning. This biosensor enables a semi-quantitative detection of analyte in real samples by eye-vision. Quality evaluation is carried out by measuring histamine and histidine using different analytical techniques such as UV-vis, FTIR, and fluorescence spectroscopy as well as TEM. A rapid quantitative readout of samples by UV-vis and fluorescence methods with standard instrumentation were proposed in a short time unlike chromatographic and electrophoretic methods. Sensitivity and limit of detection (LOD) of 6.59 × 10-4 and 0.6 μM, respectively, are determined for histamine as a spoilage marker with a correlation coefficient ( R 2) of 0.993.

  11. Quantitative and Qualitative Relations between Motivation and Critical-Analytic Thinking

    ERIC Educational Resources Information Center

    Miele, David B.; Wigfield, Allan

    2014-01-01

    The authors examine two kinds of factors that affect students' motivation to engage in critical-analytic thinking. The first, which includes ability beliefs, achievement values, and achievement goal orientations, influences the "quantitative" relation between motivation and critical-analytic thinking; that is, whether students are…

  12. Characteristics of Aspergillus fumigatus in Association with Stenotrophomonas maltophilia in an In Vitro Model of Mixed Biofilm

    PubMed Central

    Melloul, Elise; Luiggi, Stéphanie; Anaïs, Leslie; Arné, Pascal; Costa, Jean-Marc; Fihman, Vincent; Briard, Benoit; Dannaoui, Eric; Guillot, Jacques; Decousser, Jean-Winoc; Beauvais, Anne; Botterel, Françoise

    2016-01-01

    Background Biofilms are communal structures of microorganisms that have long been associated with a variety of persistent infections poorly responding to conventional antibiotic or antifungal therapy. Aspergillus fumigatus fungus and Stenotrophomonas maltophilia bacteria are examples of the microorganisms that can coexist to form a biofilm especially in the respiratory tract of immunocompromised patients or cystic fibrosis patients. The aim of the present study was to develop and assess an in vitro model of a mixed biofilm associating S. maltophilia and A. fumigatus by using analytical and quantitative approaches. Materials and Methods An A. fumigatus strain (ATCC 13073) expressing a Green Fluorescent Protein (GFP) and an S. maltophilia strain (ATCC 13637) were used. Fungal and bacterial inocula (105 conidia/mL and 106 cells/mL, respectively) were simultaneously deposited to initiate the development of an in vitro mixed biofilm on polystyrene supports at 37°C for 24 h. The structure of the biofilm was analysed via qualitative microscopic techniques like scanning electron and transmission electron microscopy, and fluorescence microscopy, and by quantitative techniques including qPCR and crystal violet staining. Results Analytic methods revealed typical structures of biofilm with production of an extracellular matrix (ECM) enclosing fungal hyphae and bacteria. Quantitative methods showed a decrease of A. fumigatus growth and ECM production in the mixed biofilm with antibiosis effect of the bacteria on the fungi seen as abortive hyphae, limited hyphal growth, fewer conidia, and thicker fungal cell walls. Conclusion For the first time, a mixed A. fumigatus—S. maltophilia biofilm was validated by various analytical and quantitative approaches and the bacterial antibiosis effect on the fungus was demonstrated. The mixed biofilm model is an interesting experimentation field to evaluate efficiency of antimicrobial agents and to analyse the interactions between the biofilm and the airways epithelium. PMID:27870863

  13. A simple and sensitive method for the determination of fibric acids in the liver by liquid chromatography.

    PubMed

    Karahashi, Minako; Fukuhara, Hiroto; Hoshina, Miki; Sakamoto, Takeshi; Yamazaki, Tohru; Mitsumoto, Atsushi; Kawashima, Yoichi; Kudo, Naomi

    2014-01-01

    Fibrates are used in biochemical and pharmacological studies as bioactive tools. Nevertheless, most studies have lacked information concerning the concentrations of fibric acids working inside tissues because a simple and sensitive method is not available for their quantitation. This study aimed to develop a simple and sensitive bioanalytical method for the quantitation of clofibric, bezafibric and fenofibric acids in samples of very small portions of tissues. Fibric acids were extracted into n-hexane-ethyl acetate from tissue homogenates (10 mg of liver, kidney or muscle) or serum (100 µL) and were derivatized with 4-bromomethyl-6,7-dimethoxycoumarin, followed by HPLC with fluorescence detection. These compounds were separated isocratically on a reversed phase with acetonitrile-water. Standard analytical curves were linear over the concentration range of 0.2-20 nmol/10 mg of liver. Precision and accuracy were within acceptable limits. Recovery from liver homogenates ranged from 93.03 to 112.29%. This method enabled the quantitation of fibric acids in 10 mg of liver from rats treated with clofibric acid, bezafibric acid or fenofibrate. From these analytical data, it became clear that there was no large difference in ratio of acyl-CoA oxidase 1 (Acox1) mRNA level to fibric acid content in the liver among the three fibric acids, suggesting that these three fibric acids have similar potency to increase expression of the Acox1 gene, which is a target of peroxisome proliferator-activated receptor α. Thus, the proposed method is a simple, sensitive and reliable tool for the quantitation of fibric acids working in vivo inside livers.

  14. Development and validation of a micellar electrokinetic chromatography method for quantitative determination of butenolides in Piper malacophyllum (C. Presl) C. DC.

    PubMed

    de Oliveira, Alberto; Silva, Claudinei A; Silva, Adalberto M; Tavares, Marina F M; Kato, Massuo J

    2010-01-01

    A large number of natural and synthetic compounds having butenolides as a core unit have been described and many of them display a wide range of biological activities. Butenolides from P. malacophyllum have presented potential antifungal activities but no specific, fast, and precise method has been developed for their determination. To develop a methodology based on micellar electrokinetic chromatography to determine butenolides in Piper species. The extracts were analysed in an uncoated fused-silica capillaries and for the micellar system 20 mmol/L SDS, 20% (v/v) acetonitrile (ACN) and 10 mmol/L STB aqueous buffer at pH 9.2 were used. The method was validated for precision, linearity, limit of detection (LOD) and limit of quantitation (LOQ) and the standard deviations were determined from the standard errors estimated by the regression line. A micellar electrokinetic chromatography (MEKC) method for determination of butenolides in extracts gave full resolution for 1 and 2. The analytical curve in the range 10.0-50.0 µg/mL (r(2) = 0.999) provided LOD and LOQ for 1 and 2 of 2.1/6.3 and 1.1/3.5 µg/mL, respectively. The RSD for migration times were 0.12 and 1.0% for peak area ratios with 100.0 ± 1.4% of recovery. A novel high-performance MEKC method developed for the analysis of butenolides 1 and 2 in leaf extracts of P. malacophyllum allowed their quantitative determined within an analysis time shorter than 5 min and the results indicated CE to be a feasible analytical technique for the quantitative determination of butenolides in Piper extracts. Copyright © 2010 John Wiley & Sons, Ltd.

  15. PAUSE: Predictive Analytics Using SPARQL-Endpoints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sukumar, Sreenivas R; Ainsworth, Keela; Bond, Nathaniel

    2014-07-11

    This invention relates to the medical industry and more specifically to methods of predicting risks. With the impetus towards personalized and evidence-based medicine, the need for a framework to analyze/interpret quantitative measurements (blood work, toxicology, etc.) with qualitative descriptions (specialist reports after reading images, bio-medical knowledgebase, etc.) to predict diagnostic risks is fast emerging. We describe a software solution that leverages hardware for scalable in-memory analytics and applies next-generation semantic query tools on medical data.

  16. Homogeneous Immunoassays: Historical Perspective and Future Promise

    NASA Astrophysics Data System (ADS)

    Ullman, Edwin F.

    1999-06-01

    The founding and growth of Syva Company is examined in the context of its leadership role in the development of homogeneous immunoassays. The simple mix and read protocols of these methods offer advantages in routine analytical and clinical applications. Early homogeneous methods were based on insensitive detection of immunoprecipitation during antigen/antibody binding. The advent of reporter groups in biology provided a means of quantitating immunochemical binding by labeling antibody or antigen and physically separating label incorporated into immune complexes from free label. Although high sensitivity was achieved, quantitative separations were experimentally demanding. Only when it became apparent that reporter groups could provide information, not only about the location of a molecule but also about its microscopic environment, was it possible to design practical non-separation methods. The evolution of early homogenous immunoassays was driven largely by the development of improved detection strategies. The first commercial spin immunoassays, developed by Syva for drug abuse testing during the Vietnam war, were followed by increasingly powerful methods such as immunochemical modulation of enzyme activity, fluorescence, and photo-induced chemiluminescence. Homogeneous methods that quantify analytes at femtomolar concentrations within a few minutes now offer important new opportunities in clinical diagnostics, nucleic acid detection and drug discovery.

  17. Faults and foibles of quantitative scanning electron microscopy/energy dispersive x-ray spectrometry (SEM/EDS)

    NASA Astrophysics Data System (ADS)

    Newbury, Dale E.; Ritchie, Nicholas W. M.

    2012-06-01

    Scanning electron microscopy with energy dispersive x-ray spectrometry (SEM/EDS) is a powerful and flexible elemental analysis method that can identify and quantify elements with atomic numbers > 4 (Be) present as major constituents (where the concentration C > 0.1 mass fraction, or 10 weight percent), minor (0.01<= C <= 0.1) and trace (C < 0.01, with a minimum detectable limit of ~+/- 0.0005 - 0.001 under routine measurement conditions, a level which is analyte and matrix dependent ). SEM/EDS can select specimen volumes with linear dimensions from ~ 500 nm to 5 μm depending on composition (masses ranging from ~ 10 pg to 100 pg) and can provide compositional maps that depict lateral elemental distributions. Despite the maturity of SEM/EDS, which has a history of more than 40 years, and the sophistication of modern analytical software, the method is vulnerable to serious shortcomings that can lead to incorrect elemental identifications and quantification errors that significantly exceed reasonable expectations. This paper will describe shortcomings in peak identification procedures, limitations on the accuracy of quantitative analysis due to specimen topography or failures in physical models for matrix corrections, and quantitative artifacts encountered in xray elemental mapping. Effective solutions to these problems are based on understanding the causes and then establishing appropriate measurement science protocols. NIST DTSA II and Lispix are open source analytical software available free at www.nist.gov that can aid the analyst in overcoming significant limitations to SEM/EDS.

  18. Preparing systems engineering and computing science students in disciplined methods, quantitative, and advanced statistical techniques to improve process performance

    NASA Astrophysics Data System (ADS)

    McCray, Wilmon Wil L., Jr.

    The research was prompted by a need to conduct a study that assesses process improvement, quality management and analytical techniques taught to students in U.S. colleges and universities undergraduate and graduate systems engineering and the computing science discipline (e.g., software engineering, computer science, and information technology) degree programs during their academic training that can be applied to quantitatively manage processes for performance. Everyone involved in executing repeatable processes in the software and systems development lifecycle processes needs to become familiar with the concepts of quantitative management, statistical thinking, process improvement methods and how they relate to process-performance. Organizations are starting to embrace the de facto Software Engineering Institute (SEI) Capability Maturity Model Integration (CMMI RTM) Models as process improvement frameworks to improve business processes performance. High maturity process areas in the CMMI model imply the use of analytical, statistical, quantitative management techniques, and process performance modeling to identify and eliminate sources of variation, continually improve process-performance; reduce cost and predict future outcomes. The research study identifies and provides a detail discussion of the gap analysis findings of process improvement and quantitative analysis techniques taught in U.S. universities systems engineering and computing science degree programs, gaps that exist in the literature, and a comparison analysis which identifies the gaps that exist between the SEI's "healthy ingredients " of a process performance model and courses taught in U.S. universities degree program. The research also heightens awareness that academicians have conducted little research on applicable statistics and quantitative techniques that can be used to demonstrate high maturity as implied in the CMMI models. The research also includes a Monte Carlo simulation optimization model and dashboard that demonstrates the use of statistical methods, statistical process control, sensitivity analysis, quantitative and optimization techniques to establish a baseline and predict future customer satisfaction index scores (outcomes). The American Customer Satisfaction Index (ACSI) model and industry benchmarks were used as a framework for the simulation model.

  19. Quantitative fingerprinting by headspace--two-dimensional comprehensive gas chromatography-mass spectrometry of solid matrices: some challenging aspects of the exhaustive assessment of food volatiles.

    PubMed

    Nicolotti, Luca; Cordero, Chiara; Cagliero, Cecilia; Liberto, Erica; Sgorbini, Barbara; Rubiolo, Patrizia; Bicchi, Carlo

    2013-10-10

    The study proposes an investigation strategy that simultaneously provides detailed profiling and quantitative fingerprinting of food volatiles, through a "comprehensive" analytical platform that includes sample preparation by Headspace Solid Phase Microextraction (HS-SPME), separation by two-dimensional comprehensive gas chromatography coupled with mass spectrometry detection (GC×GC-MS) and data processing using advanced fingerprinting approaches. Experiments were carried out on roasted hazelnuts and on Gianduja pastes (sugar, vegetable oil, hazelnuts, cocoa, nonfat dried milk, vanilla flavorings) and demonstrated that the information potential of each analysis can better be exploited if suitable quantitation methods are applied. Quantitation approaches through Multiple Headspace Extraction and Standard Addition were compared in terms of performance parameters (linearity, precision, accuracy, Limit of Detection and Limit of Quantitation) under headspace linearity conditions. The results on 19 key analytes, potent odorants, and technological markers, and more than 300 fingerprint components, were used for further processing to obtain information concerning the effect of the matrix on volatile release, and to produce an informative chemical blueprint for use in sensomics and flavoromics. The importance of quantitation approaches in headspace analysis of solid matrices of complex composition, and the advantages of MHE, are also critically discussed. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Ruggedness testing and validation of a practical analytical method for > 100 veterinary drug residues in bovine muscle by ultrahigh performance liquid chromatography – tandem mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    In this study, optimization, extension, and validation of a streamlined, qualitative and quantitative multiclass, multiresidue method was conducted to monitor great than100 veterinary drug residues in meat using ultrahigh-performance liquid chromatography – tandem mass spectrometry (UHPLC-MS/MS). I...

  1. Examining the Impact of Scoring Methods on the Institutional EFL Writing Assessment: A Turkish Perspective

    ERIC Educational Resources Information Center

    Han, Turgay; Huang, Jinyan

    2017-01-01

    Using generalizability (G-) theory and rater interviews as both quantitative and qualitative approaches, this study examined the impact of scoring methods (i.e., holistic versus analytic scoring) on the scoring variability and reliability of an EFL institutional writing assessment at a Turkish university. Ten raters were invited to rate 36…

  2. Validation of the Mass-Extraction-Window for Quantitative Methods Using Liquid Chromatography High Resolution Mass Spectrometry.

    PubMed

    Glauser, Gaétan; Grund, Baptiste; Gassner, Anne-Laure; Menin, Laure; Henry, Hugues; Bromirski, Maciej; Schütz, Frédéric; McMullen, Justin; Rochat, Bertrand

    2016-03-15

    A paradigm shift is underway in the field of quantitative liquid chromatography-mass spectrometry (LC-MS) analysis thanks to the arrival of recent high-resolution mass spectrometers (HRMS). The capability of HRMS to perform sensitive and reliable quantifications of a large variety of analytes in HR-full scan mode is showing that it is now realistic to perform quantitative and qualitative analysis with the same instrument. Moreover, HR-full scan acquisition offers a global view of sample extracts and allows retrospective investigations as virtually all ionized compounds are detected with a high sensitivity. In time, the versatility of HRMS together with the increasing need for relative quantification of hundreds of endogenous metabolites should promote a shift from triple-quadrupole MS to HRMS. However, a current "pitfall" in quantitative LC-HRMS analysis is the lack of HRMS-specific guidance for validated quantitative analyses. Indeed, false positive and false negative HRMS detections are rare, albeit possible, if inadequate parameters are used. Here, we investigated two key parameters for the validation of LC-HRMS quantitative analyses: the mass accuracy (MA) and the mass-extraction-window (MEW) that is used to construct the extracted-ion-chromatograms. We propose MA-parameters, graphs, and equations to calculate rational MEW width for the validation of quantitative LC-HRMS methods. MA measurements were performed on four different LC-HRMS platforms. Experimentally determined MEW values ranged between 5.6 and 16.5 ppm and depended on the HRMS platform, its working environment, the calibration procedure, and the analyte considered. The proposed procedure provides a fit-for-purpose MEW determination and prevents false detections.

  3. Analytical robustness of quantitative NIR chemical imaging for Islamic paper characterization

    NASA Astrophysics Data System (ADS)

    Mahgoub, Hend; Gilchrist, John R.; Fearn, Thomas; Strlič, Matija

    2017-07-01

    Recently, spectral imaging techniques such as Multispectral (MSI) and Hyperspectral Imaging (HSI) have gained importance in the field of heritage conservation. This paper explores the analytical robustness of quantitative chemical imaging for Islamic paper characterization by focusing on the effect of different measurement and processing parameters, i.e. acquisition conditions and calibration on the accuracy of the collected spectral data. This will provide a better understanding of the technique that can provide a measure of change in collections through imaging. For the quantitative model, special calibration target was devised using 105 samples from a well-characterized reference Islamic paper collection. Two material properties were of interest: starch sizing and cellulose degree of polymerization (DP). Multivariate data analysis methods were used to develop discrimination and regression models which were used as an evaluation methodology for the metrology of quantitative NIR chemical imaging. Spectral data were collected using a pushbroom HSI scanner (Gilden Photonics Ltd) in the 1000-2500 nm range with a spectral resolution of 6.3 nm using a mirror scanning setup and halogen illumination. Data were acquired at different measurement conditions and acquisition parameters. Preliminary results showed the potential of the evaluation methodology to show that measurement parameters such as the use of different lenses and different scanning backgrounds may not have a great influence on the quantitative results. Moreover, the evaluation methodology allowed for the selection of the best pre-treatment method to be applied to the data.

  4. Quantitative Methods in Psychology: Inevitable and Useless

    PubMed Central

    Toomela, Aaro

    2010-01-01

    Science begins with the question, what do I want to know? Science becomes science, however, only when this question is justified and the appropriate methodology is chosen for answering the research question. Research question should precede the other questions; methods should be chosen according to the research question and not vice versa. Modern quantitative psychology has accepted method as primary; research questions are adjusted to the methods. For understanding thinking in modern quantitative psychology, two epistemologies should be distinguished: structural-systemic that is based on Aristotelian thinking, and associative-quantitative that is based on Cartesian–Humean thinking. The first aims at understanding the structure that underlies the studied processes; the second looks for identification of cause–effect relationships between the events with no possible access to the understanding of the structures that underlie the processes. Quantitative methodology in particular as well as mathematical psychology in general, is useless for answering questions about structures and processes that underlie observed behaviors. Nevertheless, quantitative science is almost inevitable in a situation where the systemic-structural basis of behavior is not well understood; all sorts of applied decisions can be made on the basis of quantitative studies. In order to proceed, psychology should study structures; methodologically, constructive experiments should be added to observations and analytic experiments. PMID:21833199

  5. Quantitative methods in psychology: inevitable and useless.

    PubMed

    Toomela, Aaro

    2010-01-01

    Science begins with the question, what do I want to know? Science becomes science, however, only when this question is justified and the appropriate methodology is chosen for answering the research question. Research question should precede the other questions; methods should be chosen according to the research question and not vice versa. Modern quantitative psychology has accepted method as primary; research questions are adjusted to the methods. For understanding thinking in modern quantitative psychology, two epistemologies should be distinguished: structural-systemic that is based on Aristotelian thinking, and associative-quantitative that is based on Cartesian-Humean thinking. The first aims at understanding the structure that underlies the studied processes; the second looks for identification of cause-effect relationships between the events with no possible access to the understanding of the structures that underlie the processes. Quantitative methodology in particular as well as mathematical psychology in general, is useless for answering questions about structures and processes that underlie observed behaviors. Nevertheless, quantitative science is almost inevitable in a situation where the systemic-structural basis of behavior is not well understood; all sorts of applied decisions can be made on the basis of quantitative studies. In order to proceed, psychology should study structures; methodologically, constructive experiments should be added to observations and analytic experiments.

  6. A UPLC-MS/MS method for simultaneous quantitation of three monoterpene glycosides and four alkaloids in rat plasma: application to a comparative pharmacokinetic study of Huo Luo Xiao Ling Dan and single herb extract.

    PubMed

    Ai, Yu; Wu, Yun; Wang, Fenrong; Ma, Wen; Bian, Qiaoxia; Lee, David Y-W; Dai, Ronghua

    2015-03-01

    The objective of this study was to develop a sensitive and reliable ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for simultaneous quantitation of three monoterpene glycosides (paeoniflorin, alibiflorin and oxypaeoniflorin) and four alkaloids (tetrahydropalmatine, corydaline, dehydrocorydaline and berberine), the main active ingredients of Radix Paeoniae Rubra extract (RPE) and Corydalis yanhusuo extract (CYE) in Huo Luo Xiao Ling Dan (HLXLD), and to compare the pharmacokinetics of these active ingredients in normal and arthritic rats orally administrated with HLXLD or RPE/CYE alone. The analytes and internal standard (IS) (geniposide) were separated on a XBridge C18 column (150 × 4.6 mm, 3.5 µm) using gradient elution with the mobile phase consisting of methanol and 0.01% formic acid in water at a flow rate of 0.6 ml/min. The detection of the analytes was performed on Acquity UPLC-MS/MS system with an electrospray ionization and multiple reaction monitoring mode via polarity switching between negative (for monoterpene glycosides) and positive (for alkaloids) ionization mode. The lower limits of quantification were 2.5, 1, 0.5, 0.2, 0.2, 0.02 and 0.01 ng/ml for paeoniflorin, alibiflorin, oxypaeoniflorin, tetrahydropalmatine, corydaline, dehydrocorydaline and berberine, respectively. Intra-day and inter-day precision and accuracy of analytes were well within acceptance criteria (15%). The mean extraction recoveries of analytes and IS from rat plasma were all more than 83.1%. The validated method has been successfully applied to determination of the analytes. Results showed that there were remarkable differences in pharmacokinetic properties of the analytes between herbal formula and single herb group, normal and arthritic group. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Solid-phase microextraction with temperature-programmed desorption for the analysis of iodination disinfection byproducts.

    PubMed

    Frazey, P A; Barkley, R M; Sievers, R E

    1998-02-01

    An analytical approach for the determination of chlorination and iodination disinfection byproducts based on solid-phase microextraction (SPME) was developed. Solid-phase microextraction presents a simple, rapid, sensitive, and solvent-free approach to sample preparation in which analytes in either air or water matrixes are extracted into the polymeric coating of an optical fiber. Analytes are subsequently thermally desorbed in the injection port of a gas chromatograph for separation, detection, and quantitation. Thermal degradation of iodoform was observed during desorption from a polyacrylate fiber in initial GC/MS and GC/ECD experiments. Experiments were designed to determine SPME conditions that would allow quantification without significant degradation of analytes. Isothermal and temperature-programmed thermal desorptions were evaluated for efficacy in transferring analytes with wide-ranging volatilities and thermal stabilities into chromatographic analysis columns. A temperature-programmed desorption (TPD) (120-200 degrees C at 5 degrees C/min with an on-column injection port or 150-200 degrees C at 25 degrees C/min with a split/splitless injection port) was able to efficiently remove analytes with wide-ranging volatilities without causing thermal degradation. The SPME-TPD method was linear over 2-3 orders of magnitude with an electron capture detector and detection limits were in the submicrogram per liter range. Precision and detection limits for selected trihalomethanes were comparable to those of EPA method 551. Extraction efficiencies were not affected by the presence of 10 mg/L soap, 15 mg/L sodium iodide, and 6000 mg/L sodium thiosulfate. The SPME-TPD technique was applied to the determination of iodination disinfection byproducts from individual precursor compounds using GC/MS and to the quantitation of iodoform at trace levels in a water recycle system using GC/ECD.

  8. Validation of HPLC method for the simultaneous and quantitative determination of 12 UV-filters in cosmetics.

    PubMed

    Nyeborg, M; Pissavini, M; Lemasson, Y; Doucet, O

    2010-02-01

    The aim of the study was the validation of a high-performance liquid chromatography (HPLC) method for the simultaneous and quantitative determination of twelve commonly used organic UV-filters (phenylbenzimidazole sulfonic acid, benzophenone-3, isoamyl p-methoxycinnamate, diethylamino hydroxybenzoyl hexyl benzoate, octocrylene, ethylhexyl methoxycinnamate, ethylhexyl salicylate, butyl methoxydibenzoylmethane, diethylhexyl butamido triazone, ethylhexyl triazone, methylene bis-benzotriazolyl tetramethylbutylphenol and bis-ethylhexyloxyphenol methoxyphenyl triazine) contained in suncare products. The separation and quantitative determination was performed in <30 min, using a Symmetry Shield(R) C18 (5 microm) column from Waters and a mobile phase (gradient mode) consisting of ethanol and acidified water. UV measurements were carried out at multi-wavelengths, according to the absorption of the analytes.

  9. Development of analytical methods for multiplex bio-assay with inductively coupled plasma mass spectrometry.

    PubMed

    Ornatsky, Olga I; Kinach, Robert; Bandura, Dmitry R; Lou, Xudong; Tanner, Scott D; Baranov, Vladimir I; Nitz, Mark; Winnik, Mitchell A

    2008-01-01

    Advances in the development of highly multiplexed bio-analytical assays with inductively coupled plasma mass spectrometry (ICP-MS) detection are discussed. Use of novel reagents specifically designed for immunological methods utilizing elemental analysis is presented. The major steps of method development, including selection of elements for tags, validation of tagged reagents, and examples of multiplexed assays, are considered in detail. The paper further describes experimental protocols for elemental tagging of antibodies, immunostaining of live and fixed human leukemia cells, and preparation of samples for ICP-MS analysis. Quantitative analysis of surface antigens on model cell lines using a cocktail of seven lanthanide labeled antibodies demonstrated high specificity and concordance with conventional immunophenotyping.

  10. Standardization of chemical analytical techniques for pyrolysis bio-oil: history, challenges, and current status of methods

    DOE PAGES

    Ferrell, Jack R.; Olarte, Mariefel V.; Christensen, Earl D.; ...

    2016-07-05

    Here, we discuss the standardization of analytical techniques for pyrolysis bio-oils, including the current status of methods, and our opinions on future directions. First, the history of past standardization efforts is summarized, and both successful and unsuccessful validation of analytical techniques highlighted. The majority of analytical standardization studies to-date has tested only physical characterization techniques. In this paper, we present results from an international round robin on the validation of chemical characterization techniques for bio-oils. Techniques tested included acid number, carbonyl titrations using two different methods (one at room temperature and one at 80 °C), 31P NMR for determination ofmore » hydroxyl groups, and a quantitative gas chromatography–mass spectrometry (GC-MS) method. Both carbonyl titration and acid number methods have yielded acceptable inter-laboratory variabilities. 31P NMR produced acceptable results for aliphatic and phenolic hydroxyl groups, but not for carboxylic hydroxyl groups. As shown in previous round robins, GC-MS results were more variable. Reliable chemical characterization of bio-oils will enable upgrading research and allow for detailed comparisons of bio-oils produced at different facilities. Reliable analytics are also needed to enable an emerging bioenergy industry, as processing facilities often have different analytical needs and capabilities than research facilities. We feel that correlations in reliable characterizations of bio-oils will help strike a balance between research and industry, and will ultimately help to -determine metrics for bio-oil quality. Lastly, the standardization of additional analytical methods is needed, particularly for upgraded bio-oils.« less

  11. Standardization of chemical analytical techniques for pyrolysis bio-oil: history, challenges, and current status of methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferrell, Jack R.; Olarte, Mariefel V.; Christensen, Earl D.

    Here, we discuss the standardization of analytical techniques for pyrolysis bio-oils, including the current status of methods, and our opinions on future directions. First, the history of past standardization efforts is summarized, and both successful and unsuccessful validation of analytical techniques highlighted. The majority of analytical standardization studies to-date has tested only physical characterization techniques. In this paper, we present results from an international round robin on the validation of chemical characterization techniques for bio-oils. Techniques tested included acid number, carbonyl titrations using two different methods (one at room temperature and one at 80 °C), 31P NMR for determination ofmore » hydroxyl groups, and a quantitative gas chromatography–mass spectrometry (GC-MS) method. Both carbonyl titration and acid number methods have yielded acceptable inter-laboratory variabilities. 31P NMR produced acceptable results for aliphatic and phenolic hydroxyl groups, but not for carboxylic hydroxyl groups. As shown in previous round robins, GC-MS results were more variable. Reliable chemical characterization of bio-oils will enable upgrading research and allow for detailed comparisons of bio-oils produced at different facilities. Reliable analytics are also needed to enable an emerging bioenergy industry, as processing facilities often have different analytical needs and capabilities than research facilities. We feel that correlations in reliable characterizations of bio-oils will help strike a balance between research and industry, and will ultimately help to -determine metrics for bio-oil quality. Lastly, the standardization of additional analytical methods is needed, particularly for upgraded bio-oils.« less

  12. Fast liquid chromatographic-tandem mass spectrometric method using mixed-mode phase chromatography and solid phase extraction for the determination of 12 mono-hydroxylated brominated diphenyl ethers in human serum.

    PubMed

    Petropoulou, Syrago-Styliani E; Duong, Wendy; Petreas, Myrto; Park, June-Soo

    2014-08-22

    Hydroxylated polybrominated diphenyl ethers (OH-PBDEs) are formed from the oxidative metabolism of polybrominated diphenyl ethers (PBDEs) in humans, rats and mice, but their quantitation in human blood and other matrices with liquid chromatography-mass spectrometric techniques has been a challenge. In this study, a novel analytical method was developed and validated using only 250 μL of human serum for the quantitation of twelve OH-PBDEs, fully chromatographically separated in a 15 min analytical run. This method includes two novel approaches: an enzymatic hydrolysis procedure and a chromatographic separation using a mixed mode chromatography column. The enzymatic hydrolysis (EH) was found critical for 4'-OH-BDE17, which was not detectable without it. For the sample clean up, a solid phase extraction protocol was developed and validated for the extraction of the 12 congeners from human serum. In addition, for the first time baseline resolution of two components was achieved that correspond to a single peak previously identified as 6'-OH-BDE99. The method was validated for linearity, accuracy, precision, matrix effects, limit of quantification, limit of detection, sample stability and overall efficiency. Recoveries (absolute and relative) ranged from 66 to 130% with relative standard deviations <21% for all analytes. Limit of detection and quantitation ranged from 4 to 90 pg mL(-1) and 6-120 pg mL(-1), respectively, with no carry over effects. This method was applied in ten commercially available human serum samples from the general US population. The mean values of the congeners detected in all samples are 4'-OH-BDE17 (34.2 pg mL(-1)), 4-OH-BDE42 (33.9 pg mL(-1)), 5-OH-BDE47 (17.5 pg mL(-1)) and 4'-OH-BDE49 (12.4 pg mL(-1)). Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Multi-class multi-residue analysis of veterinary drugs in meat using enhanced matrix removal lipid cleanup and liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhao, Limian; Lucas, Derick; Long, David; Richter, Bruce; Stevens, Joan

    2018-05-11

    This study presents the development and validation of a quantitation method for the analysis of multi-class, multi-residue veterinary drugs using lipid removal cleanup cartridges, enhanced matrix removal lipid (EMR-Lipid), for different meat matrices by liquid chromatography tandem mass spectrometry detection. Meat samples were extracted using a two-step solid-liquid extraction followed by pass-through sample cleanup. The method was optimized based on the buffer and solvent composition, solvent additive additions, and EMR-Lipid cartridge cleanup. The developed method was then validated in five meat matrices, porcine muscle, bovine muscle, bovine liver, bovine kidney and chicken liver to evaluate the method performance characteristics, such as absolute recoveries and precision at three spiking levels, calibration curve linearity, limit of quantitation (LOQ) and matrix effect. The results showed that >90% of veterinary drug analytes achieved satisfactory recovery results of 60-120%. Over 97% analytes achieved excellent reproducibility results (relative standard deviation (RSD) < 20%), and the LOQs were 1-5 μg/kg in the evaluated meat matrices. The matrix co-extractive removal efficiency by weight provided by EMR-lipid cartridge cleanup was 42-58% in samples. The post column infusion study showed that the matrix ion suppression was reduced for samples with the EMR-Lipid cartridge cleanup. The reduced matrix ion suppression effect was also confirmed with <15% frequency of compounds with significant quantitative ion suppression (>30%) for all tested veterinary drugs in all of meat matrices. The results showed that the two-step solid-liquid extraction provides efficient extraction for the entire spectrum of veterinary drugs, including the difficult classes such as tetracyclines, beta-lactams etc. EMR-Lipid cartridges after extraction provided efficient sample cleanup with easy streamlined protocol and minimal impacts on analytes recovery, improving method reliability and consistency. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Trends of non-destructive analytical methods for identification of biodiesel feedstock in diesel-biodiesel blend according to European Commission Directive 2012/0288/EC and detecting diesel-biodiesel blend adulteration: A brief review.

    PubMed

    Mazivila, Sarmento Júnior

    2018-04-01

    Discrimination of biodiesel feedstock present in diesel-biodiesel blend is challenging due to the great similarity in the spectral profile as well as digital image profile of each type of feedstock employed in biodiesel production. Once the marketed diesel-biodiesel blend is subsidized, in which motivates adulteration in biofuel blend by cheaper supplies with high solubility to obtain profits associated with the subsidies involved in biodiesel production. Non-destructive analytical methods based on qualitative and quantitative analysis for detecting marketed diesel-biodiesel blend adulteration are reviewed. Therefore, at the end is discussed the advantage of the qualitative analysis over quantitative analysis, when the systems require immediate decisions such as to know if the marketed diesel-biodiesel blend is unadulterated or adulterated in order to aid the analyst in selecting the most appropriate green analytical procedure for detecting diesel-biodiesel blend adulteration proceeding in fast way. This critical review provides a brief review on the non-destructive analytical methods reported in scientific literature based on different first-order multivariate calibration models coupled with spectroscopy data and digital image data to identify the type of biodiesel feedstock present in diesel-biodiesel blend in order to meets the strategies adopted by European Commission Directive 2012/0288/EC as well as to monitoring diesel-biodiesel adulteration. According to that Directive, from 2020 biodiesel produced from first-generation feedstock, that is, oils employed in human food such as sunflower, soybean, rapeseed, palm oil, among other oils should not be subsidized. Therefore, those non-destructive analytical methods here reviewed are helpful for discrimination of biodiesel feedstock present in diesel-biodiesel blend according to European Commission Directive 2012/0288/EC as well as for detecting diesel-biodiesel blend adulteration. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Quantitative determination of methamphetamine in oral fluid by liquid-liquid extraction and gas chromatography/mass spectrometry.

    PubMed

    Bahmanabadi, L; Akhgari, M; Jokar, F; Sadeghi, H B

    2017-02-01

    Methamphetamine abuse is one of the most medical and social problems many countries face. In spite of the ban on the use of methamphetamine, it is widely available in Iran's drug black market. There are many analytical methods for the detection of methamphetamine in biological specimen. Oral fluid has become a popular specimen to test for the presence of methamphetamine. The purpose of the present study was to develop a method for the extraction and detection of methamphetamine in oral fluid samples using liquid-liquid extraction (LLE) and gas chromatography/mass spectrometry (GC/MS) methods. An analytical study was designed in that blank and 50 authentic oral fluid samples were collected to be first extracted by LLE and subsequently analysed by GC/MS. The method was fully validated and showed an excellent intra- and inter-assay precision (reflex sympathetic dystrophy ˂ 10%) for external quality control samples. Recovery with LLE methods was 96%. Limit of detection and limit of quantitation were 5 and 15 ng/mL, respectively. The method showed high selectivity, no additional peak due to interfering substances in samples was observed. The introduced method was sensitive, accurate and precise enough for the extraction of methamphetamine from oral fluid samples in forensic toxicology laboratories.

  16. Correction for isotopic interferences between analyte and internal standard in quantitative mass spectrometry by a nonlinear calibration function.

    PubMed

    Rule, Geoffrey S; Clark, Zlatuse D; Yue, Bingfang; Rockwood, Alan L

    2013-04-16

    Stable isotope-labeled internal standards are of great utility in providing accurate quantitation in mass spectrometry (MS). An implicit assumption has been that there is no "cross talk" between signals of the internal standard and the target analyte. In some cases, however, naturally occurring isotopes of the analyte do contribute to the signal of the internal standard. This phenomenon becomes more pronounced for isotopically rich compounds, such as those containing sulfur, chlorine, or bromine, higher molecular weight compounds, and those at high analyte/internal standard concentration ratio. This can create nonlinear calibration behavior that may bias quantitative results. Here, we propose the use of a nonlinear but more accurate fitting of data for these situations that incorporates one or two constants determined experimentally for each analyte/internal standard combination and an adjustable calibration parameter. This fitting provides more accurate quantitation in MS-based assays where contributions from analyte to stable labeled internal standard signal exist. It can also correct for the reverse situation where an analyte is present in the internal standard as an impurity. The practical utility of this approach is described, and by using experimental data, the approach is compared to alternative fits.

  17. Critical factors determining the quantification capability of matrix-assisted laser desorption/ionization– time-of-flight mass spectrometry

    PubMed Central

    Wang, Chia-Chen; Lai, Yin-Hung; Ou, Yu-Meng; Chang, Huan-Tsung; Wang, Yi-Sheng

    2016-01-01

    Quantitative analysis with mass spectrometry (MS) is important but challenging. Matrix-assisted laser desorption/ionization (MALDI) coupled with time-of-flight (TOF) MS offers superior sensitivity, resolution and speed, but such techniques have numerous disadvantages that hinder quantitative analyses. This review summarizes essential obstacles to analyte quantification with MALDI-TOF MS, including the complex ionization mechanism of MALDI, sensitive characteristics of the applied electric fields and the mass-dependent detection efficiency of ion detectors. General quantitative ionization and desorption interpretations of ion production are described. Important instrument parameters and available methods of MALDI-TOF MS used for quantitative analysis are also reviewed. This article is part of the themed issue ‘Quantitative mass spectrometry’. PMID:27644968

  18. Mixed Methods in CAM Research: A Systematic Review of Studies Published in 2012

    PubMed Central

    Bishop, Felicity L.; Holmes, Michelle M.

    2013-01-01

    Background. Mixed methods research uses qualitative and quantitative methods together in a single study or a series of related studies. Objectives. To review the prevalence and quality of mixed methods studies in complementary medicine. Methods. All studies published in the top 10 integrative and complementary medicine journals in 2012 were screened. The quality of mixed methods studies was appraised using a published tool designed for mixed methods studies. Results. 4% of papers (95 out of 2349) reported mixed methods studies, 80 of which met criteria for applying the quality appraisal tool. The most popular formal mixed methods design was triangulation (used by 74% of studies), followed by embedded (14%), sequential explanatory (8%), and finally sequential exploratory (5%). Quantitative components were generally of higher quality than qualitative components; when quantitative components involved RCTs they were of particularly high quality. Common methodological limitations were identified. Most strikingly, none of the 80 mixed methods studies addressed the philosophical tensions inherent in mixing qualitative and quantitative methods. Conclusions and Implications. The quality of mixed methods research in CAM can be enhanced by addressing philosophical tensions and improving reporting of (a) analytic methods and reflexivity (in qualitative components) and (b) sampling and recruitment-related procedures (in all components). PMID:24454489

  19. Extraction, isolation, and purification of analytes from samples of marine origin--a multivariate task.

    PubMed

    Liguori, Lucia; Bjørsvik, Hans-René

    2012-12-01

    The development of a multivariate study for a quantitative analysis of six different polybrominated diphenyl ethers (PBDEs) in tissue of Atlantic Salmo salar L. is reported. An extraction, isolation, and purification process based on an accelerated solvent extraction system was designed, investigated, and optimized by means of statistical experimental design and multivariate data analysis and regression. An accompanying gas chromatography-mass spectrometry analytical method was developed for the identification and quantification of the analytes, BDE 28, BDE 47, BDE 99, BDE 100, BDE 153, and BDE 154. These PBDEs have been used in commercial blends that were used as flame-retardants for a variety of materials, including electronic devices, synthetic polymers and textiles. The present study revealed that an extracting solvent mixture composed of hexane and CH₂Cl₂ (10:90) provided excellent recoveries of all of the six PBDEs studied herein. A somewhat lower polarity in the extracting solvent, hexane and CH₂Cl₂ (40:60) decreased the analyte %-recoveries, which still remain acceptable and satisfactory. The study demonstrates the necessity to perform an intimately investigation of the extraction and purification process in order to achieve quantitative isolation of the analytes from the specific matrix. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Artificial neural networks applied to quantitative elemental analysis of organic material using PIXE

    NASA Astrophysics Data System (ADS)

    Correa, R.; Chesta, M. A.; Morales, J. R.; Dinator, M. I.; Requena, I.; Vila, I.

    2006-08-01

    An artificial neural network (ANN) has been trained with real-sample PIXE (particle X-ray induced emission) spectra of organic substances. Following the training stage ANN was applied to a subset of similar samples thus obtaining the elemental concentrations in muscle, liver and gills of Cyprinus carpio. Concentrations obtained with the ANN method are in full agreement with results from one standard analytical procedure, showing the high potentiality of ANN in PIXE quantitative analyses.

  1. 42 CFR 493.941 - Hematology (including routine hematology and coagulation).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... of a laboratory's responses for qualitative and quantitative hematology tests or analytes, the...) of this section. (2) For quantitative hematology tests or analytes, the program must determine the...

  2. 42 CFR 493.941 - Hematology (including routine hematology and coagulation).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... of a laboratory's responses for qualitative and quantitative hematology tests or analytes, the...) of this section. (2) For quantitative hematology tests or analytes, the program must determine the...

  3. 42 CFR 493.941 - Hematology (including routine hematology and coagulation).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... of a laboratory's responses for qualitative and quantitative hematology tests or analytes, the...) of this section. (2) For quantitative hematology tests or analytes, the program must determine the...

  4. 42 CFR 493.941 - Hematology (including routine hematology and coagulation).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... of a laboratory's responses for qualitative and quantitative hematology tests or analytes, the...) of this section. (2) For quantitative hematology tests or analytes, the program must determine the...

  5. 42 CFR 493.941 - Hematology (including routine hematology and coagulation).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... of a laboratory's responses for qualitative and quantitative hematology tests or analytes, the...) of this section. (2) For quantitative hematology tests or analytes, the program must determine the...

  6. Qualitative and quantitative analyses of flavonoids in Spirodela polyrrhiza by high-performance liquid chromatography coupled with mass spectrometry.

    PubMed

    Qiao, Xue; He, Wen-ni; Xiang, Cheng; Han, Jian; Wu, Li-jun; Guo, De-an; Ye, Min

    2011-01-01

    Spirodela polyrrhiza (L.) Schleid. is a traditional Chinese herbal medicine for the treatment of influenza. Despite its wide use in Chinese medicine, no report on quality control of this herb is available so far. To establish qualitative and quantitative analytical methods by high-performance liquid chromatography (HPLC) coupled with mass spectrometry (MS) for the quality control of S. polyrrhiza. The methanol extract of S. polyrrhiza was analysed by HPLC/ESI-MS(n). Flavonoids were identified by comparing with reference standards or according to their MS(n) (n = 2-4) fragmentation behaviours. Based on LC/MS data, a standardised HPLC fingerprint was established by analysing 15 batches of commercial herbal samples. Furthermore, quantitative analysis was conducted by determining five major flavonoids, namely luteolin 8-C-glucoside, apigenin 8-C-glucoside, luteolin 7-O-glucoside, apigenin 7-O-glucoside and luteolin. A total of 18 flavonoids were identified by LC/MS, and 14 of them were reported from this herb for the first time. The HPLC fingerprints contained 10 common peaks, and could differentiate good quality batches from counterfeits. The total contents of five major flavonoids in S. polyrrhiza varied significantly from 4.28 to 19.87 mg/g. Qualitative LC/MS and quantitative HPLC analytical methods were established for the comprehensive quality control of S. polyrrhiza. Copyright © 2011 John Wiley & Sons, Ltd.

  7. 1H NMR quantitative determination of photosynthetic pigments from green beans (Phaseolus vulgaris L.).

    PubMed

    Valverde, Juan; This, Hervé

    2008-01-23

    Using 1H nuclear magnetic resonance spectroscopy (1D and 2D), the two types of photosynthetic pigments (chlorophylls, their derivatives, and carotenoids) of "green beans" (immature pods of Phaseolus vulgaris L.) were analyzed. Compared to other analytical methods (light spectroscopy or chromatography), 1H NMR spectroscopy is a fast analytical way that provides more information on chlorophyll derivatives (allomers and epimers) than ultraviolet-visible spectroscopy. Moreover, it gives a large amount of data without prior chromatographic separation.

  8. HPLC and chemometrics-assisted UV-spectroscopy methods for the simultaneous determination of ambroxol and doxycycline in capsule

    NASA Astrophysics Data System (ADS)

    Hadad, Ghada M.; El-Gindy, Alaa; Mahmoud, Waleed M. M.

    2008-08-01

    High-performance liquid chromatography (HPLC) and multivariate spectrophotometric methods are described for the simultaneous determination of ambroxol hydrochloride (AM) and doxycycline (DX) in combined pharmaceutical capsules. The chromatographic separation was achieved on reversed-phase C 18 analytical column with a mobile phase consisting of a mixture of 20 mM potassium dihydrogen phosphate, pH 6-acetonitrile in ratio of (1:1, v/v) and UV detection at 245 nm. Also, the resolution has been accomplished by using numerical spectrophotometric methods as classical least squares (CLS), principal component regression (PCR) and partial least squares (PLS-1) applied to the UV spectra of the mixture and graphical spectrophotometric method as first derivative of the ratio spectra ( 1DD) method. Analytical figures of merit (FOM), such as sensitivity, selectivity, analytical sensitivity, limit of quantitation and limit of detection were determined for CLS, PLS-1 and PCR methods. The proposed methods were validated and successfully applied for the analysis of pharmaceutical formulation and laboratory-prepared mixtures containing the two component combination.

  9. HPLC and chemometrics-assisted UV-spectroscopy methods for the simultaneous determination of ambroxol and doxycycline in capsule.

    PubMed

    Hadad, Ghada M; El-Gindy, Alaa; Mahmoud, Waleed M M

    2008-08-01

    High-performance liquid chromatography (HPLC) and multivariate spectrophotometric methods are described for the simultaneous determination of ambroxol hydrochloride (AM) and doxycycline (DX) in combined pharmaceutical capsules. The chromatographic separation was achieved on reversed-phase C(18) analytical column with a mobile phase consisting of a mixture of 20mM potassium dihydrogen phosphate, pH 6-acetonitrile in ratio of (1:1, v/v) and UV detection at 245 nm. Also, the resolution has been accomplished by using numerical spectrophotometric methods as classical least squares (CLS), principal component regression (PCR) and partial least squares (PLS-1) applied to the UV spectra of the mixture and graphical spectrophotometric method as first derivative of the ratio spectra ((1)DD) method. Analytical figures of merit (FOM), such as sensitivity, selectivity, analytical sensitivity, limit of quantitation and limit of detection were determined for CLS, PLS-1 and PCR methods. The proposed methods were validated and successfully applied for the analysis of pharmaceutical formulation and laboratory-prepared mixtures containing the two component combination.

  10. Meta-Analysis: A Systematic Method for Synthesizing Counseling Research

    ERIC Educational Resources Information Center

    Whiston, Susan C.; Li, Peiwei

    2011-01-01

    The authors provide a template for counseling researchers who are interested in quantitatively aggregating research findings. Meta-analytic studies can provide relevant information to the counseling field by systematically synthesizing studies performed by researchers from diverse fields. Methodologically sound meta-analyses require careful…

  11. Agro-ecoregionalization of Iowa using multivariate geographical clustering

    Treesearch

    Carol L. Williams; William W. Hargrove; Matt Leibman; David E. James

    2008-01-01

    Agro-ecoregionalization is categorization of landscapes for use in crop suitability analysis, strategic agroeconomic development, risk analysis, and other purposes. Past agro-ecoregionalizations have been subjective, expert opinion driven, crop specific, and unsuitable for statistical extrapolation. Use of quantitative analytical methods provides an opportunity for...

  12. Quantitative prediction of solute strengthening in aluminium alloys.

    PubMed

    Leyson, Gerard Paul M; Curtin, William A; Hector, Louis G; Woodward, Christopher F

    2010-09-01

    Despite significant advances in computational materials science, a quantitative, parameter-free prediction of the mechanical properties of alloys has been difficult to achieve from first principles. Here, we present a new analytic theory that, with input from first-principles calculations, is able to predict the strengthening of aluminium by substitutional solute atoms. Solute-dislocation interaction energies in and around the dislocation core are first calculated using density functional theory and a flexible-boundary-condition method. An analytic model for the strength, or stress to move a dislocation, owing to the random field of solutes, is then presented. The theory, which has no adjustable parameters and is extendable to other metallic alloys, predicts both the energy barriers to dislocation motion and the zero-temperature flow stress, allowing for predictions of finite-temperature flow stresses. Quantitative comparisons with experimental flow stresses at temperature T=78 K are made for Al-X alloys (X=Mg, Si, Cu, Cr) and good agreement is obtained.

  13. Approaches to acceptable risk

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whipple, C

    Several alternative approaches to address the question {open_quotes}How safe is safe enough?{close_quotes} are reviewed and an attempt is made to apply the reasoning behind these approaches to the issue of acceptability of radiation exposures received in space. The approaches to the issue of the acceptability of technological risk described here are primarily analytical, and are drawn from examples in the management of environmental health risks. These include risk-based approaches, in which specific quantitative risk targets determine the acceptability of an activity, and cost-benefit and decision analysis, which generally focus on the estimation and evaluation of risks, benefits and costs, inmore » a framework that balances these factors against each other. These analytical methods tend by their quantitative nature to emphasize the magnitude of risks, costs and alternatives, and to downplay other factors, especially those that are not easily expressed in quantitative terms, that affect acceptance or rejection of risk. Such other factors include the issues of risk perceptions and how and by whom risk decisions are made.« less

  14. Quantitative Characterization of Tissue Microstructure with Temporal Diffusion Spectroscopy

    PubMed Central

    Xu, Junzhong; Does, Mark D.; Gore, John C.

    2009-01-01

    The signals recorded by diffusion-weighted magnetic resonance imaging (DWI) are dependent on the micro-structural properties of biological tissues, so it is possible to obtain quantitative structural information non-invasively from such measurements. Oscillating gradient spin echo (OGSE) methods have the ability to probe the behavior of water diffusion over different time scales and the potential to detect variations in intracellular structure. To assist in the interpretation of OGSE data, analytical expressions have been derived for diffusion-weighted signals with OGSE methods for restricted diffusion in some typical structures, including parallel planes, cylinders and spheres, using the theory of temporal diffusion spectroscopy. These analytical predictions have been confirmed with computer simulations. These expressions suggest how OGSE signals from biological tissues should be analyzed to characterize tissue microstructure, including how to estimate cell nuclear sizes. This approach provides a model to interpret diffusion data obtained from OGSE measurements that can be used for applications such as monitoring tumor response to treatment in vivo. PMID:19616979

  15. Total arsenic and selenium analysis in Marcellus shale, high-salinity water, and hydrofracture flowback wastewater.

    PubMed

    Balaba, Ronald S; Smart, Ronald B

    2012-11-01

    Trace levels of arsenic and selenium can be toxic to living organisms yet their quantitation in high ionic strength or high salinity aqueous media is difficult due to the matrix interferences which can either suppress or enhance the analyte signal. A modified thiol cotton fiber (TCF) method employing lower flow rates and centrifugation has been used to remove the analyte from complex aqueous media and minimize the matrix interferences. This method has been tested using a USGS (SGR-1b) certified reference shale. It has been used to analyze Marcellus shale samples following microwave digestion as well as spiked samples of high salinity water (HSW) and flow back wastewater (WRF6) obtained from an actual gas well drilling operation. Quantitation of arsenic and selenium is carried out by graphite furnace atomic spectroscopy (GFAAS). Extraction of arsenic and selenium from Marcellus shale exposed to HSW and WRF6 for varying lengths of time is also reported. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Rediscovery and Revival of Analytical Refractometry for Protein Determination: Recombining Simplicity With Accuracy in the Digital Era.

    PubMed

    Anderle, Heinz; Weber, Alfred

    2016-03-01

    Among "vintage" methods of protein determination, quantitative analytical refractometry has received far less attention than well-established pharmacopoeial techniques based on protein nitrogen content, such as Dumas combustion (1831) and Kjeldahl digestion (1883). Protein determination by quantitative refractometry dates back to 1903 and has been extensively investigated and characterized in the following 30 years, but has since vanished into a few niche applications that may not require the degree of accuracy and precision essential for pharmaceutical analysis. However, because high-resolution and precision digital refractometers have replaced manual instruments, reducing time and resource consumption, the method appears particularly attractive from an economic, ergonomic, and environmental viewpoint. The sample solution can be measured without dilution or other preparation procedures than the separation of the protein-free matrix by ultrafiltration, which might even be omitted for a constant matrix and excipient composition. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  17. Analytical Eco-Scale for Assessing the Greenness of a Developed RP-HPLC Method Used for Simultaneous Analysis of Combined Antihypertensive Medications.

    PubMed

    Mohamed, Heba M; Lamie, Nesrine T

    2016-09-01

    In the past few decades the analytical community has been focused on eliminating or reducing the usage of hazardous chemicals and solvents, in different analytical methodologies, that have been ascertained to be extremely dangerous to human health and environment. In this context, environmentally friendly, green, or clean practices have been implemented in different research areas. This study presents a greener alternative of conventional RP-HPLC methods for the simultaneous determination and quantitative analysis of a pharmaceutical ternary mixture composed of telmisartan, hydrochlorothiazide, and amlodipine besylate, using an ecofriendly mobile phase and short run time with the least amount of waste production. This solvent-replacement approach was feasible without compromising method performance criteria, such as separation efficiency, peak symmetry, and chromatographic retention. The greenness profile of the proposed method was assessed and compared with reported conventional methods using the analytical Eco-Scale as an assessment tool. The proposed method was found to be greener in terms of usage of hazardous chemicals and solvents, energy consumption, and production of waste. The proposed method can be safely used for the routine analysis of the studied pharmaceutical ternary mixture with a minimal detrimental impact on human health and the environment.

  18. Analytical Glycobiology at High Sensitivity: Current Approaches and Directions

    PubMed Central

    Novotny, Milos V.; Alley, William R.; Mann, Benjamin F.

    2013-01-01

    This review summarizes the analytical advances made during the last several years in the structural and quantitative determinations of glycoproteins in complex biological mixtures. The main analytical techniques used in the fields of glycomics and glycoproteomics involve different modes of mass spectrometry and their combinations with capillary separation methods such as microcolumn liquid chromatography and capillary electrophoresis. The needs for high-sensitivity measurements have been emphasized in the oligosaccharide profiling used in the field of biomarker discovery through MALDI mass spectrometry. High-sensitivity profiling of both glycans and glycopeptides from biological fluids and tissue extracts has been aided significantly through lectin preconcentration and the uses of affinity chromatography. PMID:22945852

  19. Selection of reference standard during method development using the analytical hierarchy process.

    PubMed

    Sun, Wan-yang; Tong, Ling; Li, Dong-xiang; Huang, Jing-yi; Zhou, Shui-ping; Sun, Henry; Bi, Kai-shun

    2015-03-25

    Reference standard is critical for ensuring reliable and accurate method performance. One important issue is how to select the ideal one from the alternatives. Unlike the optimization of parameters, the criteria of the reference standard are always immeasurable. The aim of this paper is to recommend a quantitative approach for the selection of reference standard during method development based on the analytical hierarchy process (AHP) as a decision-making tool. Six alternative single reference standards were assessed in quantitative analysis of six phenolic acids from Salvia Miltiorrhiza and its preparations by using ultra-performance liquid chromatography. The AHP model simultaneously considered six criteria related to reference standard characteristics and method performance, containing feasibility to obtain, abundance in samples, chemical stability, accuracy, precision and robustness. The priority of each alternative was calculated using standard AHP analysis method. The results showed that protocatechuic aldehyde is the ideal reference standard, and rosmarinic acid is about 79.8% ability as the second choice. The determination results successfully verified the evaluation ability of this model. The AHP allowed us comprehensive considering the benefits and risks of the alternatives. It was an effective and practical tool for optimization of reference standards during method development. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Food adulteration analysis without laboratory prepared or determined reference food adulterant values.

    PubMed

    Kalivas, John H; Georgiou, Constantinos A; Moira, Marianna; Tsafaras, Ilias; Petrakis, Eleftherios A; Mousdis, George A

    2014-04-01

    Quantitative analysis of food adulterants is an important health and economic issue that needs to be fast and simple. Spectroscopy has significantly reduced analysis time. However, still needed are preparations of analyte calibration samples matrix matched to prediction samples which can be laborious and costly. Reported in this paper is the application of a newly developed pure component Tikhonov regularization (PCTR) process that does not require laboratory prepared or reference analysis methods, and hence, is a greener calibration method. The PCTR method requires an analyte pure component spectrum and non-analyte spectra. As a food analysis example, synchronous fluorescence spectra of extra virgin olive oil samples adulterated with sunflower oil is used. Results are shown to be better than those obtained using ridge regression with reference calibration samples. The flexibility of PCTR allows including reference samples and is generic for use with other instrumental methods and food products. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Visualizing dispersive features in 2D image via minimum gradient method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    He, Yu; Wang, Yan; Shen, Zhi -Xun

    Here, we developed a minimum gradient based method to track ridge features in a 2D image plot, which is a typical data representation in many momentum resolved spectroscopy experiments. Through both analytic formulation and numerical simulation, we compare this new method with existing DC (distribution curve) based and higher order derivative based analyses. We find that the new method has good noise resilience and enhanced contrast especially for weak intensity features and meanwhile preserves the quantitative local maxima information from the raw image. An algorithm is proposed to extract 1D ridge dispersion from the 2D image plot, whose quantitative applicationmore » to angle-resolved photoemission spectroscopy measurements on high temperature superconductors is demonstrated.« less

  2. Visualizing dispersive features in 2D image via minimum gradient method

    DOE PAGES

    He, Yu; Wang, Yan; Shen, Zhi -Xun

    2017-07-24

    Here, we developed a minimum gradient based method to track ridge features in a 2D image plot, which is a typical data representation in many momentum resolved spectroscopy experiments. Through both analytic formulation and numerical simulation, we compare this new method with existing DC (distribution curve) based and higher order derivative based analyses. We find that the new method has good noise resilience and enhanced contrast especially for weak intensity features and meanwhile preserves the quantitative local maxima information from the raw image. An algorithm is proposed to extract 1D ridge dispersion from the 2D image plot, whose quantitative applicationmore » to angle-resolved photoemission spectroscopy measurements on high temperature superconductors is demonstrated.« less

  3. Influence of Pre-Analytical Factors on Thymus- and Activation-Regulated Chemokine Quantitation in Plasma

    PubMed Central

    Zhao, Xuemei; Delgado, Liliana; Weiner, Russell; Laterza, Omar F.

    2015-01-01

    Thymus- and activation-regulated chemokine (TARC) in serum/plasma associates with the disease activity of atopic dermatitis (AD), and is a promising tool for assessing the response to the treatment of the disease. TARC also exists within platelets, with elevated levels detectable in AD patients. We examined the effects of pre-analytical factors on the quantitation of TARC in human EDTA plasma. TARC levels in platelet-free plasma were significantly lower than those in platelet-containing plasma. After freeze-thaw, TARC levels increased in platelet-containing plasma, but remained unchanged in platelet-free plasma, suggesting TARC was released from the platelets during the freeze-thaw process. In contrast, TARC levels were stable in serum independent of freeze-thaw. These findings underscore the importance of pre-analytical factors to TARC quantitation. Plasma TARC levels should be measured in platelet-free plasma for accurate quantitation. Pre-analytical factors influence the quantitation, interpretation, and implementation of circulating TARC as a biomarker for the development of AD therapeutics. PMID:28936246

  4. Comparative Application of PLS and PCR Methods to Simultaneous Quantitative Estimation and Simultaneous Dissolution Test of Zidovudine - Lamivudine Tablets.

    PubMed

    Üstündağ, Özgür; Dinç, Erdal; Özdemir, Nurten; Tilkan, M Günseli

    2015-01-01

    In the development strategies of new drug products and generic drug products, the simultaneous in-vitro dissolution behavior of oral dosage formulations is the most important indication for the quantitative estimation of efficiency and biopharmaceutical characteristics of drug substances. This is to force the related field's scientists to improve very powerful analytical methods to get more reliable, precise and accurate results in the quantitative analysis and dissolution testing of drug formulations. In this context, two new chemometric tools, partial least squares (PLS) and principal component regression (PCR) were improved for the simultaneous quantitative estimation and dissolution testing of zidovudine (ZID) and lamivudine (LAM) in a tablet dosage form. The results obtained in this study strongly encourage us to use them for the quality control, the routine analysis and the dissolution test of the marketing tablets containing ZID and LAM drugs.

  5. Enantioselective reductive transformation of climbazole: A concept towards quantitative biodegradation assessment in anaerobic biological treatment processes.

    PubMed

    Brienza, Monica; Chiron, Serge

    2017-06-01

    An efficient chiral method-based using liquid chromatography-high resolution-mass spectrometry analytical method has been validated for the determination of climbazole (CBZ) enantiomers in wastewater and sludge with quantification limits below the 1 ng/L and 2 ng/g range, respectively. On the basis of this newly developed analytical method, the stereochemistry of CBZ was investigated over time in sludge biotic and sterile batch experiments under anoxic dark and light conditions and during wastewater biological treatment by subsurface flow constructed wetlands. CBZ stereoselective degradation was exclusively observed under biotic conditions, confirming the specificity of enantiomeric fraction variations to biodegradation processes. Abiotic CBZ enantiomerization was insignificant at circumneutral pH and CBZ was always biotransformed into CBZ-alcohol due to the specific and enantioselective reduction of the ketone function of CBZ into a secondary alcohol function. This transformation was almost quantitative and biodegradation gave good first order kinetic fit for both enantiomers. The possibility to apply the Rayleigh equation to enantioselective CBZ biodegradation processes was investigated. The results of enantiomeric enrichment allowed for a quantitative assessment of in situ biodegradation processes due to a good fit (R 2  > 0.96) of the anoxic/anaerobic CBZ biodegradation to the Rayleigh dependency in all the biotic microcosms and was also applied in subsurface flow constructed wetlands. This work extended the concept of applying the Rayleigh equation towards quantitative biodegradation assessment of organic contaminants to enantioselective processes operating under anoxic/anaerobic conditions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. The application of multiple reaction monitoring and multi-analyte profiling to HDL proteins

    PubMed Central

    2014-01-01

    Background HDL carries a rich protein cargo and examining HDL protein composition promises to improve our understanding of its functions. Conventional mass spectrometry methods can be lengthy and difficult to extend to large populations. In addition, without prior enrichment of the sample, the ability of these methods to detect low abundance proteins is limited. Our objective was to develop a high-throughput approach to examine HDL protein composition applicable to diabetes and cardiovascular disease (CVD). Methods We optimized two multiplexed assays to examine HDL proteins using a quantitative immunoassay (Multi-Analyte Profiling- MAP) and mass spectrometric-based quantitative proteomics (Multiple Reaction Monitoring-MRM). We screened HDL proteins using human xMAP (90 protein panel) and MRM (56 protein panel). We extended the application of these two methods to HDL isolated from a group of participants with diabetes and prior cardiovascular events and a group of non-diabetic controls. Results We were able to quantitate 69 HDL proteins using MAP and 32 proteins using MRM. For several common proteins, the use of MRM and MAP was highly correlated (p < 0.01). Using MAP, several low abundance proteins implicated in atherosclerosis and inflammation were found on HDL. On the other hand, MRM allowed the examination of several HDL proteins not available by MAP. Conclusions MAP and MRM offer a sensitive and high-throughput approach to examine changes in HDL proteins in diabetes and CVD. This approach can be used to measure the presented HDL proteins in large clinical studies. PMID:24397693

  7. New method for determination of ten pesticides in human blood.

    PubMed

    García-Repetto, R; Giménez, M P; Repetto, M

    2001-01-01

    An analytical method was developed for precise identification and quantitation of 10 pesticides in human blood. The pesticides studied, which have appeared frequently in actual cases, were endosulfan, lindane, parathion, ethyl-azinphos, diazinon, malathion, alachlor, tetradifon, fenthion and dicofol (o-p' and p-p' isomers). The current method replaces an earlier method which involved liquid-liquid extraction with a mixture of n-hexane-benzene (1 + 1). The extraction is performed by solid-phase extraction, with C18 cartridges and 2 internal standards, perthane and triphenylphosphate. Eluates were analyzed by gas chromatography (GC) with nitrogen-phosphorus and electrochemical detectors. Results were confirmed by GC-mass spectrometry in the electron impact mode. Blood blank samples spiked with 2 standard mixtures and an internal standard were used for quantitation. Mean recoveries ranged from 71.83 to 97.10%. Detection and quantitation limits are reported for each pesticide. Examples are provided to show the application of the present method to actual samples.

  8. Comparison of detection limits in environmental analysis--is it possible? An approach on quality assurance in the lower working range by verification.

    PubMed

    Geiss, S; Einax, J W

    2001-07-01

    Detection limit, reporting limit and limit of quantitation are analytical parameters which describe the power of analytical methods. These parameters are used for internal quality assurance and externally for competing, especially in the case of trace analysis in environmental compartments. The wide variety of possibilities for computing or obtaining these measures in literature and in legislative rules makes any comparison difficult. Additionally, a host of terms have been used within the analytical community to describe detection and quantitation capabilities. Without trying to create an order for the variety of terms, this paper is aimed at providing a practical proposal for answering the main questions for the analysts concerning quality measures above. These main questions and related parameters were explained and graphically demonstrated. Estimation and verification of these parameters are the two steps to get real measures. A rule for a practical verification is given in a table, where the analyst can read out what to measure, what to estimate and which criteria have to be fulfilled. In this manner verified parameters detection limit, reporting limit and limit of quantitation now are comparable and the analyst himself is responsible to the unambiguity and reliability of these measures.

  9. Wildland Fire Prevention: Today, Intuition--Tomorrow, Management

    Treesearch

    Albert J. Simard; Linda R. Donoghue

    1987-01-01

    Describes, from a historical perspective, methods used to characterize fire prevention problems and evaluate prevention programs and discusses past research efforts to bolster these analytical and management efforts. Highlights research on the sociological perspectives of the wildfire problem and on quantitative fire occurrence prediction and program evaluation systems...

  10. Utility of mass spectrometry in the diagnosis of prion diseases

    USDA-ARS?s Scientific Manuscript database

    We developed a sensitive mass spectrometry-based method of quantitating the prions present in a variety of mammalian species. Calibration curves relating the area ratios of the selected analyte peptides and their oxidized analogs to their homologous stable isotope labeled internal standards were pre...

  11. Analytical Determination of Fluoride Ion Using Gran's Semi-Antilog Plot.

    ERIC Educational Resources Information Center

    Barnhard, Ralph J.

    1983-01-01

    A quantitative determination for fluoride ion using a commercially available fluoride electrode is described. The procedure referred to as known-addition is employed with the data processed on Gran's Plot Paper. Background information, experimental procedures, and advantages/disadvantages of the method are discussed. (JN)

  12. METHODOLOGICAL APPROACH FOR MEASURING PRIORITY DBPS IN REVERSE OSMOSIS CONCENTRATED DRINKING WATER

    EPA Science Inventory

    Many disinfection by-products (DBPs) are formed when drinking water is chlorinated, but only a few are routinely measured or regulated. Various studies have revealed a plethora of DBPs for which sensitive and quantitative analytical methods have always been a major limiting facto...

  13. [Quantitative method for simultaneous assay of four coumarins with one marker in Fraxini Cortex].

    PubMed

    Feng, Weihong; Wang, Zhimin; Zhang, Qiwei; Liu, Limei; Wang, Jinyu; Yang, Fei

    2011-07-01

    To establish a new quantitative method for simultaneous determination of multi-coumarins in Fraxini Cortex by using one chemical reference substance, and validate its feasibilities. The new quality evaluation method, quantitative analysis of multi-components by singer-marker (QAMS), was established and validated with Fraxini Cortex. Four main coumarins were selected as analytes to evaluate the quality and their relative correlation factors (RCF) were determined by HPLC-DAD. Within the linear range, the values of RCF at 340 nm of aesculin to asculetin, fraxin and fraxetin were 1.771, 0.799, 1.409, respectively. And the contents of aesculin in samples of Fraxini Cortex were authentically determined by the external standard method, and the contents of the three other coumarins were calculated by their RCF. The contents of these four coumarins in all samples were also determined by the external standard method. Within a certain range, the RCF had a good reproducibility (RSD 2.5%-3.9%). Significant differences were not observed between the quantitative results of two methods. It is feasible and suitable to evaluate the quality of Fraxini Cortex and its Yinpian by QAMS.

  14. Surrogate analyte approach for quantitation of endogenous NAD(+) in human acidified blood samples using liquid chromatography coupled with electrospray ionization tandem mass spectrometry.

    PubMed

    Liu, Liling; Cui, Zhiyi; Deng, Yuzhong; Dean, Brian; Hop, Cornelis E C A; Liang, Xiaorong

    2016-02-01

    A high-performance liquid chromatography tandem mass spectrometry (LC-MS/MS) assay for the quantitative determination of NAD(+) in human whole blood using a surrogate analyte approach was developed and validated. Human whole blood was acidified using 0.5N perchloric acid at a ratio of 1:3 (v:v, blood:perchloric acid) during sample collection. 25μL of acidified blood was extracted using a protein precipitation method and the resulting extracts were analyzed using reverse-phase chromatography and positive electrospray ionization mass spectrometry. (13)C5-NAD(+) was used as the surrogate analyte for authentic analyte, NAD(+). The standard curve ranging from 0.250 to 25.0μg/mL in acidified human blood for (13)C5-NAD(+) was fitted to a 1/x(2) weighted linear regression model. The LC-MS/MS response between surrogate analyte and authentic analyte at the same concentration was obtained before and after the batch run. This response factor was not applied when determining the NAD(+) concentration from the (13)C5-NAD(+) standard curve since the percent difference was less than 5%. The precision and accuracy of the LC-MS/MS assay based on the five analytical QC levels were well within the acceptance criteria from both FDA and EMA guidance for bioanalytical method validation. Average extraction recovery of (13)C5-NAD(+) was 94.6% across the curve range. Matrix factor was 0.99 for both high and low QC indicating minimal ion suppression or enhancement. The validated assay was used to measure the baseline level of NAD(+) in 29 male and 21 female human subjects. This assay was also used to study the circadian effect of endogenous level of NAD(+) in 10 human subjects. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. On-line miniaturized asymmetrical flow field-flow fractionation-electrospray ionization-tandem mass spectrometry with selected reaction monitoring for quantitative analysis of phospholipids in plasma lipoproteins.

    PubMed

    Yang, Iseul; Kim, Ki Hun; Lee, Ju Yong; Moon, Myeong Hee

    2014-01-10

    A direct analytical method for high speed quantitative analysis of lipids in human blood plasma using on-line chip-type asymmetrical flow field-flow fractionation-electrospray ionization-tandem mass spectrometry (cAF4-ESI-MS/MS) with selected reaction monitoring (SRM) is described in this study. Utilizing a miniaturized cAF4 channel, high speed size separation of high density lipoproteins (HDL) and low density lipoproteins (LDL) from plasma samples can be accomplished at a microflow rate along with simultaneous desalting of lipoproteins, both of which are conducive to direct ESI of lipids in lipoproteins. This study demonstrates that the SRM method to monitor phospholipids during cAF4-ESI-MS/MS can be successfully applied to the quantitation of lipid molecules in plasma lipoproteins without the need of a separate lipid extraction process. For quantitation of lipids in HDL and LDL during cAF4-ESI-MS/MS runs, a protein standard (carbonic anhydrase, 29 kDa) was added to each plasma sample as an internal standard such that a peak intensity of y67(+5) ions, which are high abundant SRM product ions of CA, could be utilized to calculate the relative intensity of each lipid molecule. The developed method was applied to plasma samples from 10 patients with coronary artery disease (CAD) and 10 healthy control samples, and quantitative analysis of 39 lipid molecules including phosphatidylcholines, phosphatidylethanolamines, sphingomyelins, phosphatidylglycerols, and phosphatidylinositols, resulted in the selection of 13 PL species showing more than 2.5 fold difference in relative abundance (p<0.01) between the groups. The present study demonstrates a high speed analytical method for determining plasma lipid content and distribution without an organic solvent extraction of lipids from plasma. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Multiplexed MRM-based quantitation of candidate cancer biomarker proteins in undepleted and non-enriched human plasma.

    PubMed

    Percy, Andrew J; Chambers, Andrew G; Yang, Juncong; Borchers, Christoph H

    2013-07-01

    An emerging approach for multiplexed targeted proteomics involves bottom-up LC-MRM-MS, with stable isotope-labeled internal standard peptides, to accurately quantitate panels of putative disease biomarkers in biofluids. In this paper, we used this approach to quantitate 27 candidate cancer-biomarker proteins in human plasma that had not been treated by immunoaffinity depletion or enrichment techniques. These proteins have been reported as biomarkers for a variety of human cancers, from laryngeal to ovarian, with breast cancer having the highest correlation. We implemented measures to minimize the analytical variability, improve the quantitative accuracy, and increase the feasibility and applicability of this MRM-based method. We have demonstrated excellent retention time reproducibility (median interday CV: 0.08%) and signal stability (median interday CV: 4.5% for the analytical platform and 6.1% for the bottom-up workflow) for the 27 biomarker proteins (represented by 57 interference-free peptides). The linear dynamic range for the MRM assays spanned four orders-of-magnitude, with 25 assays covering a 10(3) -10(4) range in protein concentration. The lowest abundance quantifiable protein in our biomarker panel was insulin-like growth factor 1 (calculated concentration: 127 ng/mL). Overall, the analytical performance of this assay demonstrates high robustness and sensitivity, and provides the necessary throughput and multiplexing capabilities required to verify and validate cancer-associated protein biomarker panels in human plasma, prior to clinical use. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Kinetics analysis and quantitative calculations for the successive radioactive decay process

    NASA Astrophysics Data System (ADS)

    Zhou, Zhiping; Yan, Deyue; Zhao, Yuliang; Chai, Zhifang

    2015-01-01

    The general radioactive decay kinetics equations with branching were developed and the analytical solutions were derived by Laplace transform method. The time dependence of all the nuclide concentrations can be easily obtained by applying the equations to any known radioactive decay series. Taking the example of thorium radioactive decay series, the concentration evolution over time of various nuclide members in the family has been given by the quantitative numerical calculations with a computer. The method can be applied to the quantitative prediction and analysis for the daughter nuclides in the successive decay with branching of the complicated radioactive processes, such as the natural radioactive decay series, nuclear reactor, nuclear waste disposal, nuclear spallation, synthesis and identification of superheavy nuclides, radioactive ion beam physics and chemistry, etc.

  18. Characterization and measurement of natural gas trace constituents. Volume 1. Arsenic. Final report, June 1989-October 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chao, S.S.; Attari, A.

    1995-01-01

    The discovery of arsenic compounds, as alkylarsines, in natural gas prompted this research program to develop reliable measurement techniques needed to assess the efficiency of removal processes for these environmentally sensitive substances. These techniques include sampling, speciation, quantitation and on-line instrumental methods for monitoring the total arsenic concentration. The current program has yielded many products, including calibration standards, arsenic-specific sorbents, sensitive analytical methods and instrumentation. Four laboratory analytical methods have been developed and successfully employed for arsenic determination in natural gas. These methods use GC-AED and GC-MS instruments to speciate alkylarsines, and peroxydisulfate extraction with FIAS, special carbon sorbent withmore » XRF and an IGT developed sorbent with GFAA for total arsenic measurement.« less

  19. Challenges and perspectives in quantitative NMR.

    PubMed

    Giraudeau, Patrick

    2017-01-01

    This perspective article summarizes, from the author's point of view at the beginning of 2016, the major challenges and perspectives in the field of quantitative NMR. The key concepts in quantitative NMR are first summarized; then, the most recent evolutions in terms of resolution and sensitivity are discussed, as well as some potential future research directions in this field. A particular focus is made on methodologies capable of boosting the resolution and sensitivity of quantitative NMR, which could open application perspectives in fields where the sample complexity and the analyte concentrations are particularly challenging. These include multi-dimensional quantitative NMR and hyperpolarization techniques such as para-hydrogen-induced polarization or dynamic nuclear polarization. Because quantitative NMR cannot be dissociated from the key concepts of analytical chemistry, i.e. trueness and precision, the methodological developments are systematically described together with their level of analytical performance. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  20. ASPECTS: an automation-assisted SPE method development system.

    PubMed

    Li, Ming; Chou, Judy; King, Kristopher W; Yang, Liyu

    2013-07-01

    A typical conventional SPE method development (MD) process usually involves deciding the chemistry of the sorbent and eluent based on information about the analyte; experimentally preparing and trying out various combinations of adsorption chemistry and elution conditions; quantitatively evaluating the various conditions; and comparing quantitative results from all combination of conditions to select the best condition for method qualification. The second and fourth steps have mostly been performed manually until now. We developed an automation-assisted system that expedites the conventional SPE MD process by automating 99% of the second step, and expedites the fourth step by automatically processing the results data and presenting it to the analyst in a user-friendly format. The automation-assisted SPE MD system greatly saves the manual labor in SPE MD work, prevents analyst errors from causing misinterpretation of quantitative results, and shortens data analysis and interpretation time.

  1. Ion mobility analysis of lipoproteins

    DOEpatents

    Benner, W Henry [Danville, CA; Krauss, Ronald M [Berkeley, CA; Blanche, Patricia J [Berkeley, CA

    2007-08-21

    A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.

  2. Aerosol preparation of intact lipoproteins

    DOEpatents

    Benner, W Henry [Danville, CA; Krauss, Ronald M [Berkeley, CA; Blanche, Patricia J [Berkeley, CA

    2012-01-17

    A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.

  3. Development of analytical methods for multiplex bio-assay with inductively coupled plasma mass spectrometry

    PubMed Central

    Ornatsky, Olga I.; Kinach, Robert; Bandura, Dmitry R.; Lou, Xudong; Tanner, Scott D.; Baranov, Vladimir I.; Nitz, Mark; Winnik, Mitchell A.

    2008-01-01

    Advances in the development of highly multiplexed bio-analytical assays with inductively coupled plasma mass spectrometry (ICP-MS) detection are discussed. Use of novel reagents specifically designed for immunological methods utilizing elemental analysis is presented. The major steps of method development, including selection of elements for tags, validation of tagged reagents, and examples of multiplexed assays, are considered in detail. The paper further describes experimental protocols for elemental tagging of antibodies, immunostaining of live and fixed human leukemia cells, and preparation of samples for ICP-MS analysis. Quantitative analysis of surface antigens on model cell lines using a cocktail of seven lanthanide labeled antibodies demonstrated high specificity and concordance with conventional immunophenotyping. PMID:19122859

  4. Development of a multi-variate calibration approach for quantitative analysis of oxidation resistant Mo-Si-B coatings using laser ablation inductively coupled plasma mass spectrometry

    NASA Astrophysics Data System (ADS)

    Cakara, Anja; Bonta, Maximilian; Riedl, Helmut; Mayrhofer, Paul H.; Limbeck, Andreas

    2016-06-01

    Nowadays, for the production of oxidation protection coatings in ultrahigh temperature environments, alloys of Mo-Si-B are employed. The properties of the material, mainly the oxidation resistance, are strongly influenced by the Si to B ratio; thus reliable analytical methods are needed to assure exact determination of the material composition for the respective applications. For analysis of such coatings, laser ablation inductively coupled mass spectrometry (LA-ICP-MS) has been reported as a versatile method with no specific requirements on the nature of the sample. However, matrix effects represent the main limitation of laser-based solid sampling techniques and usually the use of matrix-matched standards for quantitative analysis is required. In this work, LA-ICP-MS analysis of samples with known composition and varying Mo, Si and B content was carried out. Between known analyte concentrations and derived LA-ICP-MS signal intensities no linear correlation could be found. In order to allow quantitative analysis independent of matrix effects, a multiple linear regression model was developed. Besides the three target analytes also the signals of possible argides (40Ar36Ar and 98Mo40Ar) as well as detected impurities of the Mo-Si-B coatings (108Pd) were considered. Applicability of the model to unknown samples was confirmed using external validation. Relative deviations from the values determined using conventional liquid analysis after sample digestion between 5 and 10% for the main components Mo and Si were observed.

  5. Monitoring of Cr, Cu, Pb, V and Zn in polluted soils by laser induced breakdown spectroscopy (LIBS).

    PubMed

    Dell'Aglio, Marcella; Gaudiuso, Rosalba; Senesi, Giorgio S; De Giacomo, Alessandro; Zaccone, Claudio; Miano, Teodoro M; De Pascale, Olga

    2011-05-01

    Laser Induced Breakdown Spectroscopy (LIBS) is a fast and multi-elemental analytical technique particularly suitable for the qualitative and quantitative analysis of heavy metals in solid samples, including environmental ones. Although LIBS is often recognised in the literature as a well-established analytical technique, results about quantitative analysis of elements in chemically complex matrices such as soils are quite contrasting. In this work, soil samples of various origins have been analyzed by LIBS and data compared to those obtained by Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES). The emission intensities of one selected line for each of the five analytes (i.e., Cr, Cu, Pb, V, and Zn) were normalized to the background signal, and plotted as a function of the concentration values previously determined by ICP-OES. Data showed a good linearity for all calibration lines drawn, and the correlation between ICP-OES and LIBS was confirmed by the satisfactory agreement obtained between the corresponding values. Consequently, LIBS method can be used at least for metal monitoring in soils. In this respect, a simple method for the estimation of the soil pollution degree by heavy metals, based on the determination of an anthropogenic index, was proposed and determined for Cr and Zn.

  6. Determination of halonitromethanes and haloacetamides: an evaluation of sample preservation and analyte stability in drinking water.

    PubMed

    Liew, Deborah; Linge, Kathryn L; Joll, Cynthia A; Heitz, Anna; Charrois, Jeffrey W A

    2012-06-08

    Simultaneous quantitation of 6 halonitromethanes (HNMs) and 5 haloacetamides (HAAms) was achieved with a simplified liquid-liquid extraction (LLE) method, followed by gas chromatography-mass spectrometry. Stability tests showed that brominated tri-HNMs immediately degraded in the presence of ascorbic acid, sodium sulphite and sodium borohydride, and also reduced in samples treated with ammonium chloride, or with no preservation. Both ammonium chloride and ascorbic acid were suitable for the preservation of HAAms. Ammonium chloride was most suitable for preserving both HNMs and HAAms, although it is recommended that samples be analysed as soon as possible after collection. While groundwater samples exhibited a greater analytical bias compared to other waters, the good recoveries (>90%) of most analytes in tap water suggest that the method is very appropriate for determining these analytes in treated drinking waters. Application of the method to water from three drinking water treatment plants in Western Australia indicating N-DBP formation did occur, with increased detections after chlorination. The method is recommended for low-cost, rapid screening of both HNMs and HAAms in drinking water. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Differential Mobility Spectrometry for Improved Selectivity in Hydrophilic Interaction Liquid Chromatography-Tandem Mass Spectrometry Analysis of Paralytic Shellfish Toxins

    NASA Astrophysics Data System (ADS)

    Beach, Daniel G.

    2017-08-01

    Paralytic shellfish toxins (PSTs) are neurotoxins produced by dinoflagellates and cyanobacteria that cause paralytic shellfish poisoning in humans. PST quantitation by LC-MS is challenging because of their high polarity, lability as gas-phase ions, and large number of potentially interfering analogues. Differential mobility spectrometry (DMS) has the potential to improve the performance of LC-MS methods for PSTs in terms of selectivity and limits of detection. This work describes a comprehensive investigation of the separation of 16 regulated PSTs by DMS and the development of highly selective LC-DMS-MS methods for PST quantitation. The effects of all DMS parameters on the separation of PSTs from one another were first investigated in detail. The labile nature of 11α-gonyautoxin epimers gave unique insight into fragmentation of labile analytes before, during, and after the DMS analyzer. Two sets of DMS parameters were identified that either optimized the resolution of PSTs from one another or transmitted them at a limited number of compensation voltage (CV) values corresponding to structural subclasses. These were used to develop multidimensional LC-DMS-MS/MS methods using existing HILIC-MS/MS parameters. In both cases, improved selectivity was observed when using DMS, and the quantitative capabilities of a rapid UPLC-DMS-MS/MS method were evaluated. Limits of detection of the developed method were similar to those without DMS, and differences were highly analyte-dependant. Analysis of shellfish matrix reference materials showed good agreement with established methods. The developed methods will be useful in cases where specific matrix interferences are encountered in the LC-MS/MS analysis of PSTs in complex biological samples.

  8. Simple and ultra-fast recognition and quantitation of compounded monoclonal antibodies: Application to flow injection analysis combined to UV spectroscopy and matching method.

    PubMed

    Jaccoulet, E; Schweitzer-Chaput, A; Toussaint, B; Prognon, P; Caudron, E

    2018-09-01

    Compounding of monoclonal antibody (mAbs) constantly increases in hospital. Quality control (QC) of the compounded mAbs based on quantification and identification is required to prevent potential errors and fast method is needed to manage outpatient chemotherapy administration. A simple and ultra-fast (less than 30 s) method using flow injection analysis associated to least square matching method issued from the analyzer software was performed and evaluated for the routine hospital QC of three compounded mAbs: bevacizumab, infliximab and rituximab. The method was evaluated through qualitative and quantitative parameters. Preliminary analysis of the UV absorption and second derivative spectra of the mAbs allowed us to adapt analytical conditions according to the therapeutic range of the mAbs. In terms of quantitative QC, linearity, accuracy and precision were assessed as specified in ICH guidelines. Very satisfactory recovery was achieved and the RSD (%) of the intermediate precision were less than 1.1%. Qualitative analytical parameters were also evaluated in terms of specificity, sensitivity and global precision through a matrix of confusion. Results showed to be concentration and mAbs dependant and excellent (100%) specificity and sensitivity were reached within specific concentration range. Finally, routine application on "real life" samples (n = 209) from different batch of the three mAbs complied with the specifications of the quality control i.e. excellent identification (100%) and ± 15% of targeting concentration belonging to the calibration range. The successful use of the combination of second derivative spectroscopy and partial least square matching method demonstrated the interest of FIA for the ultra-fast QC of mAbs after compounding using matching method. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. DNA DAMAGE QUANTITATION BY ALKALINE GEL ELECTROPHORESIS.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    SUTHERLAND,B.M.; BENNETT,P.V.; SUTHERLAND, J.C.

    2004-03-24

    Physical and chemical agents in the environment, those used in clinical applications, or encountered during recreational exposures to sunlight, induce damages in DNA. Understanding the biological impact of these agents requires quantitation of the levels of such damages in laboratory test systems as well as in field or clinical samples. Alkaline gel electrophoresis provides a sensitive (down to {approx} a few lesions/5Mb), rapid method of direct quantitation of a wide variety of DNA damages in nanogram quantities of non-radioactive DNAs from laboratory, field, or clinical specimens, including higher plants and animals. This method stems from velocity sedimentation studies of DNAmore » populations, and from the simple methods of agarose gel electrophoresis. Our laboratories have developed quantitative agarose gel methods, analytical descriptions of DNA migration during electrophoresis on agarose gels (1-6), and electronic imaging for accurate determinations of DNA mass (7-9). Although all these components improve sensitivity and throughput of large numbers of samples (7,8,10), a simple version using only standard molecular biology equipment allows routine analysis of DNA damages at moderate frequencies. We present here a description of the methods, as well as a brief description of the underlying principles, required for a simplified approach to quantitation of DNA damages by alkaline gel electrophoresis.« less

  10. Separation-oriented derivatization of native fluorescent compounds through fluorous labeling followed by liquid chromatography with fluorous-phase.

    PubMed

    Sakaguchi, Yohei; Yoshida, Hideyuki; Todoroki, Kenichiro; Nohta, Hitoshi; Yamaguchi, Masatoshi

    2009-06-15

    We have developed a new and simple method based on "fluorous derivatization" for LC of native fluorescent compounds. This method involves the use of a column with a fluorous stationary phase. Native fluorescent analytes with target functional groups are precolumn derivatized with a nonfluorescent fluorous tag, and the fluorous-labeled analytes are retained in the column, whereas underivatized substances are not. Only the retained fluorescent analytes are detected fluorometrically at appropriate retention times, and retained substrates without fluorophores are not detected. In this study, biologically important carboxylic acids (homovanillic acid, vanillylmandelic acid, and 5-hydroxyindoleacetic acid) and drugs (naproxen, felbinac, flurbiprofen, and etodolac) were used as model native fluorescent compounds. Experimental results indicate that the fluorous-phase column can selectively retain fluorous compounds including fluorous-labeled analytes on the basis of fluorous separation. We believe that separation-oriented derivatization presented here is the first step toward the introduction of fluorous derivatization in quantitative LC analysis.

  11. Comparison of critical methods developed for fatty acid analysis: A review.

    PubMed

    Wu, Zhuona; Zhang, Qi; Li, Ning; Pu, Yiqiong; Wang, Bing; Zhang, Tong

    2017-01-01

    Fatty acids are important nutritional substances and metabolites in living organisms. These acids are abundant in Chinese herbs, such as Brucea javanica, Notopterygium forbesii, Isatis tinctoria, Astragalus membranaceus, and Aconitum szechenyianum. This review illustrates the types of fatty acids and their significant roles in the human body. Many analytical methods are used for the qualitative and quantitative evaluation of fatty acids. Some of the methods used to analyze fatty acids in more than 30 kinds of plants, drugs, and other samples are presented in this paper. These analytical methods include gas chromatography, liquid chromatography, near-infrared spectroscopy, and NMR spectroscopy. The advantages and disadvantages of these techniques are described and compared. This review provides a valuable reference for establishing methods for fatty acid determination. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Application of High-Performance Liquid Chromatography Coupled with Linear Ion Trap Quadrupole Orbitrap Mass Spectrometry for Qualitative and Quantitative Assessment of Shejin-Liyan Granule Supplements.

    PubMed

    Gu, Jifeng; Wu, Weijun; Huang, Mengwei; Long, Fen; Liu, Xinhua; Zhu, Yizhun

    2018-04-11

    A method for high-performance liquid chromatography coupled with linear ion trap quadrupole Orbitrap high-resolution mass spectrometry (HPLC-LTQ-Orbitrap MS) was developed and validated for the qualitative and quantitative assessment of Shejin-liyan Granule. According to the fragmentation mechanism and high-resolution MS data, 54 compounds, including fourteen isoflavones, eleven ligands, eight flavonoids, six physalins, six organic acids, four triterpenoid saponins, two xanthones, two alkaloids, and one licorice coumarin, were identified or tentatively characterized. In addition, ten of the representative compounds (matrine, galuteolin, tectoridin, iridin, arctiin, tectorigenin, glycyrrhizic acid, irigenin, arctigenin, and irisflorentin) were quantified using the validated HPLC-LTQ-Orbitrap MS method. The method validation showed a good linearity with coefficients of determination (r²) above 0.9914 for all analytes. The accuracy of the intra- and inter-day variation of the investigated compounds was 95.0-105.0%, and the precision values were less than 4.89%. The mean recoveries and reproducibilities of each analyte were 95.1-104.8%, with relative standard deviations below 4.91%. The method successfully quantified the ten compounds in Shejin-liyan Granule, and the results show that the method is accurate, sensitive, and reliable.

  13. Construction of measurement uncertainty profiles for quantitative analysis of genetically modified organisms based on interlaboratory validation data.

    PubMed

    Macarthur, Roy; Feinberg, Max; Bertheau, Yves

    2010-01-01

    A method is presented for estimating the size of uncertainty associated with the measurement of products derived from genetically modified organisms (GMOs). The method is based on the uncertainty profile, which is an extension, for the estimation of uncertainty, of a recent graphical statistical tool called an accuracy profile that was developed for the validation of quantitative analytical methods. The application of uncertainty profiles as an aid to decision making and assessment of fitness for purpose is also presented. Results of the measurement of the quantity of GMOs in flour by PCR-based methods collected through a number of interlaboratory studies followed the log-normal distribution. Uncertainty profiles built using the results generally give an expected range for measurement results of 50-200% of reference concentrations for materials that contain at least 1% GMO. This range is consistent with European Network of GM Laboratories and the European Union (EU) Community Reference Laboratory validation criteria and can be used as a fitness for purpose criterion for measurement methods. The effect on the enforcement of EU labeling regulations is that, in general, an individual analytical result needs to be < 0.45% to demonstrate compliance, and > 1.8% to demonstrate noncompliance with a labeling threshold of 0.9%.

  14. A differential mobility spectrometry/mass spectrometry platform for the rapid detection and quantitation of DNA adduct dG-ABP.

    PubMed

    Kafle, Amol; Klaene, Joshua; Hall, Adam B; Glick, James; Coy, Stephen L; Vouros, Paul

    2013-07-15

    There is continued interest in exploring new analytical technologies for the detection and quantitation of DNA adducts, biomarkers which provide direct evidence of exposure and genetic damage in cells. With the goal of reducing clean-up steps and improving sample throughput, a Differential Mobility Spectrometry/Mass Spectrometry (DMS/MS) platform has been introduced for adduct analysis. A DMS/MS platform has been utilized for the analysis of dG-ABP, the deoxyguanosine adduct of the bladder carcinogen 4-aminobiphenyl (4-ABP). After optimization of the DMS parameters, each sample was analyzed in just 30 s following a simple protein precipitation step of the digested DNA. A detection limit of one modification in 10^6 nucleosides has been achieved using only 2 µg of DNA. A brief comparison (quantitative and qualitative) with liquid chromatography/mass spectrometry is also presented highlighting the advantages of using the DMS/MS method as a high-throughput platform. The data presented demonstrate the successful application of a DMS/MS/MS platform for the rapid quantitation of DNA adducts using, as a model analyte, the deoxyguanosine adduct of the bladder carcinogen 4-aminobiphenyl. Copyright © 2013 John Wiley & Sons, Ltd.

  15. Nuclear magnetic resonance and high-performance liquid chromatography techniques for the characterization of bioactive compounds from Humulus lupulus L. (hop).

    PubMed

    Bertelli, Davide; Brighenti, Virginia; Marchetti, Lucia; Reik, Anna; Pellati, Federica

    2018-06-01

    Humulus lupulus L. (hop) represents one of the most cultivated crops, it being a key ingredient in the brewing process. Many health-related properties have been described for hop extracts, making this plant gain more interest in the field of pharmaceutical and nutraceutical research. Among the analytical tools available for the phytochemical characterization of plant extracts, quantitative nuclear magnetic resonance (qNMR) represents a new and powerful technique. In this ambit, the present study was aimed at the development of a new, simple, and efficient qNMR method for the metabolite fingerprinting of bioactive compounds in hop cones, taking advantage of the novel ERETIC 2 tool. To the best of our knowledge, this is the first attempt to apply this method to complex matrices of natural origin, such as hop extracts. The qNMR method set up in this study was applied to the quantification of both prenylflavonoids and bitter acids in eight hop cultivars. The performance of this analytical method was compared with that of HPLC-UV/DAD, which represents the most frequently used technique in the field of natural product analysis. The quantitative data obtained for hop samples by means of the two aforementioned techniques highlighted that the amount of bioactive compounds was slightly higher when qNMR was applied, although the order of magnitude of the values was the same. The accuracy of qNMR was comparable to that of the chromatographic method, thus proving to be a reliable tool for the analysis of these secondary metabolites in hop extracts. Graphical abstract Graphical abstract related to the extraction and analytical methods applied in this work for the analysis of bioactive compounds in Humulus lupulus L. (hop) cones.

  16. Quantitative DNA fiber mapping

    DOEpatents

    Gray, Joe W.; Weier, Heinz-Ulrich G.

    1998-01-01

    The present invention relates generally to the DNA mapping and sequencing technologies. In particular, the present invention provides enhanced methods and compositions for the physical mapping and positional cloning of genomic DNA. The present invention also provides a useful analytical technique to directly map cloned DNA sequences onto individual stretched DNA molecules.

  17. Quantitative analysis of Sudan dye adulteration in paprika powder using FTIR spectroscopy

    USDA-ARS?s Scientific Manuscript database

    The presence of Sudan dye used illegally for coloring in food stuffs has become a point of food safety concern, especially in paprika- and chili-containing food products. Fourier transform infrared (FTIR) spectroscopy has been extensively used as an analytical method for quality control and safety m...

  18. Evaluation of PLS, LS-SVM, and LWR for quantitative spectroscopic analysis of soils

    USDA-ARS?s Scientific Manuscript database

    Soil testing requires the analysis of large numbers of samples in laboratory that are often time consuming and expensive. Mid-infrared spectroscopy (mid-IR) and near-infrared spectroscopy (NIRS) are fast, non-destructive, and inexpensive analytical methods that have been used for soil analysis, in l...

  19. TRACE-LEVEL MEASUREMENT OF COMPLEX COMBUSTION EFFLUENTS AND RESIDUES USING MULTIDIMENSIONAL GAS CHROMATOGRAPHY-MASS SPECTROMETRY (MDGC-MS). (R828190)

    EPA Science Inventory

    The identification and quantitation of non-method-specific target analytes have greater importance with respect to EPA's current combustion strategy. The risk associated with combustion process emissions must now be characterized. EPA has recently released draft guidance on pr...

  20. DETERMINATION OF SEX HORMONES AND NONYLPHENOL ETHOXYLATES IN THE AQUEOUS MATRIXES OF TWO PILOT-SCALE MUNICIPAL WASTEWATER TREATMENT PLANTS

    EPA Science Inventory

    Two analytical methods were developed and refined for the detection and quantitation of two groups of endocrine-disrupting chemicals (EDCs) in the liquid matrixes of two pilot-scale municipal wastewater treatment plants. The targeted compounds are seven sex hormones (estradiol, ...

  1. Effectiveness of Motivational Interviewing Interventions for Adolescent Substance Use Behavior Change: A Meta-Analytic Review

    ERIC Educational Resources Information Center

    Jensen, Chad D.; Cushing, Christopher C.; Aylward, Brandon S.; Craig, James T.; Sorell, Danielle M.; Steele, Ric G.

    2011-01-01

    Objective: This study was designed to quantitatively evaluate the effectiveness of motivational interviewing (MI) interventions for adolescent substance use behavior change. Method: Literature searches of electronic databases were undertaken in addition to manual reference searches of identified review articles. Databases searched include…

  2. Oxidation of methionine 216 in sheep and elk prion protein is highly dependent upon the amino acid at position 218 but is not important for prion propagation

    USDA-ARS?s Scientific Manuscript database

    We developed a sensitive mass spectrometry-based method of quantitating the prions present in elk and sheep. Calibration curves relating the area ratios of the selected analyte peptides and their homologous stable isotope labeled internal standards were prepared. This method was compared to the ELIS...

  3. Measurement of Henry's Law Constants Using Internal Standards: A Quantitative GC Experiment for the Instrumental Analysis or Environmental Chemistry Laboratory

    ERIC Educational Resources Information Center

    Ji, Chang; Boisvert, Susanne M.; Arida, Ann-Marie C.; Day, Shannon E.

    2008-01-01

    An internal standard method applicable to undergraduate instrumental analysis or environmental chemistry laboratory has been designed and tested to determine the Henry's law constants for a series of alkyl nitriles. In this method, a mixture of the analytes and an internal standard is prepared and used to make a standard solution (organic solvent)…

  4. Introduction to special section of the Journal of Family Psychology, advances in mixed methods in family psychology: integrative and applied solutions for family science.

    PubMed

    Weisner, Thomas S; Fiese, Barbara H

    2011-12-01

    Mixed methods in family psychology refer to the systematic integration of qualitative and quantitative techniques to represent family processes and settings. Over the past decade, significant advances have been made in study design, analytic strategies, and technological support (such as software) that allow for the integration of quantitative and qualitative methods and for making appropriate inferences from mixed methods. This special section of the Journal of Family Psychology illustrates how mixed methods may be used to advance knowledge in family science through identifying important cultural differences in family structure, beliefs, and practices, and revealing patterns of family relationships to generate new measurement paradigms and inform clinical practice. Guidance is offered to advance mixed methods research in family psychology through sound principles of peer review.

  5. An approximate analytical solution for describing surface runoff and sediment transport over hillslope

    NASA Astrophysics Data System (ADS)

    Tao, Wanghai; Wang, Quanjiu; Lin, Henry

    2018-03-01

    Soil and water loss from farmland causes land degradation and water pollution, thus continued efforts are needed to establish mathematical model for quantitative analysis of relevant processes and mechanisms. In this study, an approximate analytical solution has been developed for overland flow model and sediment transport model, offering a simple and effective means to predict overland flow and erosion under natural rainfall conditions. In the overland flow model, the flow regime was considered to be transitional with the value of parameter β (in the kinematic wave model) approximately two. The change rate of unit discharge with distance was assumed to be constant and equal to the runoff rate at the outlet of the plane. The excess rainfall was considered to be constant under uniform rainfall conditions. The overland flow model developed can be further applied to natural rainfall conditions by treating excess rainfall intensity as constant over a small time interval. For the sediment model, the recommended values of the runoff erosion calibration constant (cr) and the splash erosion calibration constant (cf) have been given in this study so that it is easier to use the model. These recommended values are 0.15 and 0.12, respectively. Comparisons with observed results were carried out to validate the proposed analytical solution. The results showed that the approximate analytical solution developed in this paper closely matches the observed data, thus providing an alternative method of predicting runoff generation and sediment yield, and offering a more convenient method of analyzing the quantitative relationships between variables. Furthermore, the model developed in this study can be used as a theoretical basis for developing runoff and erosion control methods.

  6. Quantitative mass spectrometry of unconventional human biological matrices

    NASA Astrophysics Data System (ADS)

    Dutkiewicz, Ewelina P.; Urban, Pawel L.

    2016-10-01

    The development of sensitive and versatile mass spectrometric methodology has fuelled interest in the analysis of metabolites and drugs in unconventional biological specimens. Here, we discuss the analysis of eight human matrices-hair, nail, breath, saliva, tears, meibum, nasal mucus and skin excretions (including sweat)-by mass spectrometry (MS). The use of such specimens brings a number of advantages, the most important being non-invasive sampling, the limited risk of adulteration and the ability to obtain information that complements blood and urine tests. The most often studied matrices are hair, breath and saliva. This review primarily focuses on endogenous (e.g. potential biomarkers, hormones) and exogenous (e.g. drugs, environmental contaminants) small molecules. The majority of analytical methods used chromatographic separation prior to MS; however, such a hyphenated methodology greatly limits analytical throughput. On the other hand, the mass spectrometric methods that exclude chromatographic separation are fast but suffer from matrix interferences. To enable development of quantitative assays for unconventional matrices, it is desirable to standardize the protocols for the analysis of each specimen and create appropriate certified reference materials. Overcoming these challenges will make analysis of unconventional human biological matrices more common in a clinical setting. This article is part of the themed issue 'Quantitative mass spectrometry'.

  7. Simultaneous determination of thirteen different steroid hormones using micro UHPLC-MS/MS with on-line SPE system.

    PubMed

    Márta, Zoltán; Bobály, Balázs; Fekete, Jenő; Magda, Balázs; Imre, Tímea; Mészáros, Katalin Viola; Bálint, Mária; Szabó, Pál Tamás

    2018-02-20

    Ultratrace analysis of sample components requires excellent analytical performance in terms of limits of quantitation (LOQ). Micro UHPLC coupled to sensitive tandem mass spectrometry provides state of the art solution for such analytical problems. Using on-line SPE with column switching on a micro UHPLC-MS/MS system allowed to decrease LOQ without any complex sample preparation protocol. The presented method is capable of reaching satisfactory low LOQ values for analysis of thirteen different steroid molecules from human plasma without the most commonly used off-line SPE or compound derivatization. Steroids were determined by using two simple sample preparation methods, based on lower and higher plasma steroid concentrations. In the first method, higher analyte concentrations were directly determined after protein precipitation with methanol. The organic phase obtained from the precipitation was diluted with water and directly injected into the LC-MS system. In the second method, low steroid levels were determined by concentrating the organic phase after steroid extraction. In this case, analytes were extracted with ethyl acetate and reconstituted in 90/10 water/acetonitrile following evaporation to dryness. This step provided much lower LOQs, outperforming previously published values. The method has been validated and subsequently applied to clinical laboratory measurement. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Stable isotope dilution ultra-high performance liquid chromatography-tandem mass spectrometry quantitative profiling of tryptophan-related neuroactive substances in human serum and cerebrospinal fluid.

    PubMed

    Hényková, Eva; Vránová, Hana Přikrylová; Amakorová, Petra; Pospíšil, Tomáš; Žukauskaitė, Asta; Vlčková, Magdaléna; Urbánek, Lubor; Novák, Ondřej; Mareš, Jan; Kaňovský, Petr; Strnad, Miroslav

    2016-03-11

    Many compounds related to L-tryptophan (L-TRP) have interesting biological or pharmacological activity, and their abnormal neurotransmission seems to be linked to a wide range of neurodegenerative and psychiatric diseases. A high-throughput method based on ultra-high performance liquid chromatography connected to electrospray tandem mass spectrometry (UHPLC-ESI-MS/MS) was developed for the quantitative analysis of L-TRP and 16 of its metabolites in human serum and cerebrospinal fluid (CSF), representing both major and minor routes of L-TRP catabolism. The combination of a fast LC gradient with selective tandem mass spectrometry enabled accurate analysis of almost 100 samples in 24h. The standard isotope dilution method was used for quantitative determination. The method's lower limits of quantification for serum and cerebrospinal fluid ranged from 0.05 to 15nmol/L and 0.3 to 45nmol/L, respectively. Analytical recoveries ranged from 10.4 to 218.1% for serum and 22.1 to 370.0% for CSF. The method's accuracy ranged from 82.4 to 128.5% for serum matrix and 90.7 to 127.7% for CSF matrix. All intra- and inter-day coefficients of variation were below 15%. These results demonstrate that the new method is capable of quantifying endogenous serum and CSF levels of a heterogeneous group of compounds spanning a wide range of concentrations. The method was used to determine the physiological levels of target analytes in serum and CSF samples from 18 individuals, demonstrating its reliability and potential usefulness in large-scale epidemiological studies. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Rapid and sensitive liquid chromatography-tandem mass spectrometric method for the quantitative determination of potentially harmful substance 5,5'-oxydimethylenebis (2-furfural) in traditional Chinese medicine injections.

    PubMed

    Zang, Qingce; Gao, Yang; Huang, Luojiao; He, Jiuming; Lin, Sheng; Jin, Hongtao; Zhang, Ruiping; Abliz, Zeper

    2018-03-01

    With the rapid development and wide application of traditional Chinese medicine injection (TCMI), a number of adverse events of some TCMIs have incessantly been reported and have drawn broad attention in recent years. Establishing effective and practical analytical methods for safety evaluation and quality control of TCMI can help to improve the safety of TCMIs in clinical applications. In this study, a sensitive and rapid high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method has been developed and validated for the quantitative determination of potentially harmful substance 5,5'-oxydimethylenebis (2-furfural, OMBF) in TCMI samples. Chromatographic separation was performed on a C18 reversed-phase column (150 mm × 2.1 mm, 5 µm) by gradient elution, using methanol-water containing 0.1% formic acid as mobile phase at the flow rate of 0.3 mL/min. MS/MS detection was performed on a triple quadrupole mass spectrometer with positive electrospray ionization in the multiple reaction-monitoring mode. The method was sensitive with a limit of quantification of 0.3 ng/mL and linear over the range of 0.3-30 ng/mL ( r =0.9998). Intra- and inter-day precision for analyte was <9.52% RSD with recoveries in the range 88.0-109.67% at three concentration levels. The validated method was successfully applied to quantitatively determine the compound OMBF in TCMIs and glucose injections. Our study indicates that this method is simple, sensitive, practicable and reliable, and could be applied for safety evaluation and quality control of TCMIs and glucose injections.

  10. Isolation and determination of ivermectin in post-mortem and in vivo tissues of dung beetles using a continuous solid phase extraction method followed by LC-ESI+-MS/MS

    PubMed Central

    Ortiz, Antonio J.; Cortez, Vieyle; Azzouz, Abdelmonaim

    2017-01-01

    A new analytical method based on solvent extraction, followed by continuous solid-phase extraction (SPE) clean-up using a polymeric sorbent, was demonstrated to be applicable for the detection of ivermectin in complex biological matrices of dung beetles (hemolymph, excreta or dry tissues) using liquid chromatography combined with positive electrospray ionization tandem mass spectrometry (LC/ESI+–MS/MS). Using a signal-to-noise ratio of 3:1, the limit of detection (LOD) in the insect matrices at trace levels was 0.01 ng g–1 and the limit of quantification (LOQ) was 0.1 ng g–1. The proposed method was successfully used to quantitatively determine the levels of ivermectin in the analysis of small samples in in vivo and post mortem samples, demonstrating the usefulness for quantitative analyses that are focused on future pharmacokinetic and bioavailability studies in insects and the establishment of a new protocol to study the impact of ivermectin on non-target arthropods such as dung beetles and other insects that are related with the “dung community”. Because satisfactory precision and accuracy values were obtained in both in vivo matrices, we suggest that the method can be consistently used for quantitative determinations that are focused on future pharmacokinetic and bioavailability studies in insects. Furthermore, this new analytical method was successfully applied to biological samples of dead dung beetles from the field suggesting that the method can be used to establish a new routine analysis of ivermectin residues in insect carcasses that is applied to complement typical mortality tests. PMID:28207908

  11. Reverse Transcription Quantitative Polymerase Chain Reaction for Detection of and Differentiation Between RNA and DNA of HIV-1-Based Lentiviral Vectors.

    PubMed

    Pavlovic, Melanie; Koehler, Nina; Anton, Martina; Dinkelmeier, Anna; Haase, Maren; Stellberger, Thorsten; Busch, Ulrich; Baiker, Armin E

    2017-08-01

    The purpose of the described method is the detection of and differentiation between RNA and DNA of human immunodeficiency virus (HIV)-derived lentiviral vectors (LV) in cell culture supernatants and swab samples. For the analytical surveillance of genetic engineering, operations methods for the detection of the HIV-1-based LV generations are required. Furthermore, for research issues, it is important to prove the absence of LV particles for downgrading experimental settings in terms of the biosafety level. Here, a quantitative polymerase chain reaction method targeting the long terminal repeat U5 subunit and the start sequence of the packaging signal ψ is described. Numerous controls are included in order to monitor the technical procedure.

  12. Sonic horizon formation for oscillating Bose-Einstein condensates in isotropic harmonic potential

    PubMed Central

    Wang, Ying; Zhou, Yu; Zhou, Shuyu

    2016-01-01

    We study the sonic horizon phenomena of the oscillating Bose-Einstein condensates in isotropic harmonic potential. Based on the Gross-Pitaevskii equation model and variational method, we derive the original analytical formula for the criteria and lifetime of the formation of the sonic horizon, demonstrating pictorially the interaction parameter dependence for the occur- rence of the sonic horizon and damping effect of the system distribution width. Our analytical results corroborate quantitatively the particular features of the sonic horizon reported in previous numerical study. PMID:27922129

  13. What we-authors, reviewers and editors of scientific work-can learn from the analytical history of biological 3-nitrotyrosine.

    PubMed

    Tsikas, Dimitrios

    2017-07-15

    Tyrosine and tyrosine residues in proteins are attacked by the reactive oxygen and nitrogen species peroxynitrite (O=N-OO - ) to generate 3-nitrotyrosine (3-NT) and 3-nitrotyrosine-proteins (3-NTProt), respectively. 3-NT and 3-NTProt are widely accepted as biomarkers of nitr(os)ative stress. Over the years many different analytical methods have been reported for 3-NT and 3-NTProt. Reported concentrations often differ by more than three orders of magnitude, indicative of serious analytical problems. Strategies to overcome pre-analytical and analytical shortcomings and pitfalls have been proposed. The present review investigated whether recently published work on the quantitative measurement of biological 3-nitrotyrosine did adequately consider the analytical past of this biomolecule. 3-Nitrotyrosine was taken as a representative of biomolecules that occur in biological samples in the pM-to-nM concentration range. This examination revealed that in many cases the main protagonists involved in the publication of scientific work, i.e., authors, reviewers and editors, failed to do so. Learning from the analytical history of 3-nitrotyrosine means advancing analytical and biological science and implies the following key issues. (1) Choosing the most reliable analytical approach in terms of sensitivity and accuracy; presently this is best feasible by stable-isotope dilution tandem mass spectrometry coupled with gas chromatography (GC-MS/MS) or liquid chromatography (LC-MS/MS). (2) Minimizing artificial formation of 3-nitrotyrosine during sample work up, a major pitfall in 3-nitrotyrosine analysis. (3) Validating adequately the final method in the intendent biological matrix and the established concentration range. (4) Inviting experts in the field for critical evaluation of the novelty and reliability of the proposed analytical method, placing special emphasis on the compliance of the analytical outcome with 3-nitrotyrosine concentrations obtained by validated GC-MS/MS and LC-MS/MS methods. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Analytical method for thermal stress analysis of plasma facing materials

    NASA Astrophysics Data System (ADS)

    You, J. H.; Bolt, H.

    2001-10-01

    The thermo-mechanical response of plasma facing materials (PFMs) to heat loads from the fusion plasma is one of the crucial issues in fusion technology. In this work, a fully analytical description of the thermal stress distribution in armour tiles of plasma facing components is presented which is expected to occur under typical high heat flux (HHF) loads. The method of stress superposition is applied considering the temperature gradient and thermal expansion mismatch. Several combinations of PFMs and heat sink metals are analysed and compared. In the framework of the present theoretical model, plastic flow and the effect of residual stress can be quantitatively assessed. Possible failure features are discussed.

  15. Separation of negatively charged carbohydrates by capillary electrophoresis.

    PubMed

    Linhardt, R J; Pervin, A

    1996-01-12

    Capillary electrophoresis (CE) has recently emerged as a highly promising technique consuming an extremely small amount of sample and capable of the rapid, high-resolution separation, characterization, and quantitation of analytes. CE has been used for the separation of biopolymers, including acidic carbohydrates. Since CE is basically an analytical method for ions, acidic carbohydrates that give anions in weakly acid, neutral, or alkaline media are often the direct objects of this method. The scope of this review is limited to the use of CE for the analysis of carbohydrates containing carboxylate, sulfate, and phosphate groups as well as neutral carbohydrates that have been derivatized to incorporate strongly acidic functionality, such as sulfonate groups.

  16. HPLC-PFD determination of priority pollutant PAHs in water, sediment, and semipermeable membrane devices

    USGS Publications Warehouse

    Williamson, K.S.; Petty, J.D.; Huckins, J.N.; Lebo, J.A.; Kaiser, E.M.

    2002-01-01

    High performance liquid chromatography coupled with programmable fluorescence detection was employed for the determination of 15 priority pollutant polycyclic aromatic hydrocarbons (PPPAHs) in water, sediment, and semipermeable membrane devices (SPMDs). Chromatographic separation using this analytical method facilitates selectivity, sensitivity (ppt levels), and can serve as a non-destructive technique for subsequent analysis by other chromatographic and spectroscopic techniques. Extraction and sample cleanup procedures were also developed for water, sediment, and SPMDs using various chromatographic and wet chemical methods. The focus of this publication is to examine the enrichment techniques and the analytical methodologies used in the isolation, characterization, and quantitation of 15 PPPAHs in different sample matrices.

  17. Targeted proteomic assays for quantitation of proteins identified by proteogenomic analysis of ovarian cancer

    DOE PAGES

    Song, Ehwang; Gao, Yuqian; Wu, Chaochao; ...

    2017-07-19

    Here, mass spectrometry (MS) based targeted proteomic methods such as selected reaction monitoring (SRM) are becoming the method of choice for preclinical verification of candidate protein biomarkers. The Clinical Proteomic Tumor Analysis Consortium (CPTAC) of the National Cancer Institute has investigated the standardization and analytical validation of the SRM assays and demonstrated robust analytical performance on different instruments across different laboratories. An Assay Portal has also been established by CPTAC to provide the research community a resource consisting of large set of targeted MS-based assays, and a depository to share assays publicly, providing that assays meet the guidelines proposed bymore » CPTAC. Herein, we report 98 SRM assays covering 70 candidate protein biomarkers previously reported as associated with ovarian cancer that have been thoroughly characterized according to the CPTAC Assay Characterization Guidance Document. The experiments, methods and results for characterizing these SRM assays for their MS response, repeatability, selectivity, stability, and reproducible detection of endogenous analytes are described in detail.« less

  18. Locating bomb factories by detecting hydrogen peroxide.

    PubMed

    Romolo, Francesco Saverio; Connell, Samantha; Ferrari, Carlotta; Suarez, Guillaume; Sauvain, Jean-Jacques; Hopf, Nancy B

    2016-11-01

    The analytical capability to detect hydrogen peroxide vapour can play a key role in localizing a site where a H2O2 based Improvised Explosive (IE) is manufactured. In security activities it is very important to obtain information in a short time. For this reason, an analytical method to be used in security activity needs portable devices. The authors have developed the first analytical method based on a portable luminometer, specifically designed and validated to locate IE manufacturing sites using quantitative on-site vapour analysis for H2O2. The method was tested both indoor and outdoor. The results demonstrate that the detection of H2O2 vapours could allow police forces to locate the site, while terrorists are preparing an attack. The collected data are also very important in developing new sensors, able to give an early alarm if located at a proper distance from a site where an H2O2 based IE is prepared. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Quantitative metabolomics by H-NMR and LC-MS/MS confirms altered metabolic pathways in diabetes.

    PubMed

    Lanza, Ian R; Zhang, Shucha; Ward, Lawrence E; Karakelides, Helen; Raftery, Daniel; Nair, K Sreekumaran

    2010-05-10

    Insulin is as a major postprandial hormone with profound effects on carbohydrate, fat, and protein metabolism. In the absence of exogenous insulin, patients with type 1 diabetes exhibit a variety of metabolic abnormalities including hyperglycemia, glycosurea, accelerated ketogenesis, and muscle wasting due to increased proteolysis. We analyzed plasma from type 1 diabetic (T1D) humans during insulin treatment (I+) and acute insulin deprivation (I-) and non-diabetic participants (ND) by (1)H nuclear magnetic resonance spectroscopy and liquid chromatography-tandem mass spectrometry. The aim was to determine if this combination of analytical methods could provide information on metabolic pathways known to be altered by insulin deficiency. Multivariate statistics differentiated proton spectra from I- and I+ based on several derived plasma metabolites that were elevated during insulin deprivation (lactate, acetate, allantoin, ketones). Mass spectrometry revealed significant perturbations in levels of plasma amino acids and amino acid metabolites during insulin deprivation. Further analysis of metabolite levels measured by the two analytical techniques indicates several known metabolic pathways that are perturbed in T1D (I-) (protein synthesis and breakdown, gluconeogenesis, ketogenesis, amino acid oxidation, mitochondrial bioenergetics, and oxidative stress). This work demonstrates the promise of combining multiple analytical methods with advanced statistical methods in quantitative metabolomics research, which we have applied to the clinical situation of acute insulin deprivation in T1D to reflect the numerous metabolic pathways known to be affected by insulin deficiency.

  20. Validation of pharmaceutical potency determinations by quantitative nuclear magnetic resonance spectrometry.

    PubMed

    Webster, Gregory K; Marsden, Ian; Pommerening, Cynthia A; Tyrakowski, Christina M

    2010-05-01

    With the changing development paradigms in the pharmaceutical industry, laboratories are challenged to release materials for clinical studies with rapid turnaround times. To minimize cost demands, many businesses are looking to develop ways of using early Good Manufacturing Practice (GMP) materials of active pharmaceutical ingredients (API) for Good Laboratory Practice (GLP) toxicology studies. To make this happen, the analytical laboratory releases the material by one of three scenarios: (1) holding the GLP release until full GMP testing is ready, (2) issuing a separate lot number for a portion of the GMP material and releasing the material for GLP use, or (3) releasing the lot of material for GLP using alternate (equivalent) method(s) not specified for GMP release testing. Many companies are finding the third scenario to be advantageous in terms of cost and efficiency through the use of quantitative nuclear magnetic resonance (q-NMR). The use of q-NMR has proved to be a single-point replacement for routine early development testing that previously combined elements of identity testing, chromatographic assay, moisture analysis, residual solvent analysis, and elemental analysis. This study highlights that q-NMR can be validated to meet current regulatory analytical method guidelines for routine pharmaceutical analysis.

  1. Fluorescence-based Western blotting for quantitation of protein biomarkers in clinical samples.

    PubMed

    Zellner, Maria; Babeluk, Rita; Diestinger, Michael; Pirchegger, Petra; Skeledzic, Senada; Oehler, Rudolf

    2008-09-01

    Since most high throughput techniques used in biomarker discovery are very time and cost intensive, highly specific and quantitative analytical alternative application methods are needed for the routine analysis. Conventional Western blotting allows detection of specific proteins to the level of single isotypes while its quantitative accuracy is rather limited. We report a novel and improved quantitative Western blotting method. The use of fluorescently labelled secondary antibodies strongly extends the dynamic range of the quantitation and improves the correlation with the protein amount (r=0.997). By an additional fluorescent staining of all proteins immediately after their transfer to the blot membrane, it is possible to visualise simultaneously the antibody binding and the total protein profile. This allows for an accurate correction for protein load. Applying this normalisation it could be demonstrated that fluorescence-based Western blotting is able to reproduce a quantitative analysis of two specific proteins in blood platelet samples from 44 subjects with different diseases as initially conducted by 2D-DIGE. These results show that the proposed fluorescence-based Western blotting is an adequate application technique for biomarker quantitation and suggest possibilities of employment that go far beyond.

  2. Evaluation of analytical performance of a new high-sensitivity immunoassay for cardiac troponin I.

    PubMed

    Masotti, Silvia; Prontera, Concetta; Musetti, Veronica; Storti, Simona; Ndreu, Rudina; Zucchelli, Gian Carlo; Passino, Claudio; Clerico, Aldo

    2018-02-23

    The study aim was to evaluate and compare the analytical performance of the new chemiluminescent immunoassay for cardiac troponin I (cTnI), called Access hs-TnI using DxI platform, with those of Access AccuTnI+3 method, and high-sensitivity (hs) cTnI method for ARCHITECT platform. The limits of blank (LoB), detection (LoD) and quantitation (LoQ) at 10% and 20% CV were evaluated according to international standardized protocols. For the evaluation of analytical performance and comparison of cTnI results, both heparinized plasma samples, collected from healthy subjects and patients with cardiac diseases, and quality control samples distributed in external quality assessment programs were used. LoB, LoD and LoQ at 20% and 10% CV values of the Access hs-cTnI method were 0.6, 1.3, 2.1 and 5.3 ng/L, respectively. Access hs-cTnI method showed analytical performance significantly better than that of Access AccuTnI+3 method and similar results to those of hs ARCHITECT cTnI method. Moreover, the cTnI concentrations measured with Access hs-cTnI method showed close linear regressions with both Access AccuTnI+3 and ARCHITECT hs-cTnI methods, although there were systematic differences between these methods. There was no difference between cTnI values measured by Access hs-cTnI in heparinized plasma and serum samples, whereas there was a significant difference between cTnI values, respectively measured in EDTA and heparin plasma samples. Access hs-cTnI has analytical sensitivity parameters significantly improved compared to Access AccuTnI+3 method and is similar to those of the high-sensitivity method using ARCHITECT platform.

  3. The Water-Energy-Food Nexus: A systematic review of methods for nexus assessment

    NASA Astrophysics Data System (ADS)

    Albrecht, Tamee R.; Crootof, Arica; Scott, Christopher A.

    2018-04-01

    The water-energy-food (WEF) nexus is rapidly expanding in scholarly literature and policy settings as a novel way to address complex resource and development challenges. The nexus approach aims to identify tradeoffs and synergies of water, energy, and food systems, internalize social and environmental impacts, and guide development of cross-sectoral policies. However, while the WEF nexus offers a promising conceptual approach, the use of WEF nexus methods to systematically evaluate water, energy, and food interlinkages or support development of socially and politically-relevant resource policies has been limited. This paper reviews WEF nexus methods to provide a knowledge base of existing approaches and promote further development of analytical methods that align with nexus thinking. The systematic review of 245 journal articles and book chapters reveals that (a) use of specific and reproducible methods for nexus assessment is uncommon (less than one-third); (b) nexus methods frequently fall short of capturing interactions among water, energy, and food—the very linkages they conceptually purport to address; (c) assessments strongly favor quantitative approaches (nearly three-quarters); (d) use of social science methods is limited (approximately one-quarter); and (e) many nexus methods are confined to disciplinary silos—only about one-quarter combine methods from diverse disciplines and less than one-fifth utilize both quantitative and qualitative approaches. To help overcome these limitations, we derive four key features of nexus analytical tools and methods—innovation, context, collaboration, and implementation—from the literature that reflect WEF nexus thinking. By evaluating existing nexus analytical approaches based on these features, we highlight 18 studies that demonstrate promising advances to guide future research. This paper finds that to address complex resource and development challenges, mixed-methods and transdisciplinary approaches are needed that incorporate social and political dimensions of water, energy, and food; utilize multiple and interdisciplinary approaches; and engage stakeholders and decision-makers.

  4. Black phosphorus-assisted laser desorption ionization mass spectrometry for the determination of low-molecular-weight compounds in biofluids.

    PubMed

    He, Xiao-Mei; Ding, Jun; Yu, Lei; Hussain, Dilshad; Feng, Yu-Qi

    2016-09-01

    Quantitative analysis of small molecules by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been a challenging task due to matrix-derived interferences in low m/z region and poor reproducibility of MS signal response. In this study, we developed an approach by applying black phosphorus (BP) as a matrix-assisted laser desorption ionization (MALDI) matrix for the quantitative analysis of small molecules for the first time. Black phosphorus-assisted laser desorption/ionization mass spectrometry (BP/ALDI-MS) showed clear background and exhibited superior detection sensitivity toward quaternary ammonium compounds compared to carbon-based materials. By combining stable isotope labeling (SIL) strategy with BP/ALDI-MS (SIL-BP/ALDI-MS), a variety of analytes labeled with quaternary ammonium group were sensitively detected. Moreover, the isotope-labeled forms of analytes also served as internal standards, which broadened the analyte coverage of BP/ALDI-MS and improved the reproducibility of MS signals. Based on these advantages, a reliable method for quantitative analysis of aldehydes from complex biological samples (saliva, urine, and serum) was successfully established. Good linearities were obtained for five aldehydes in the range of 0.1-20.0 μM with correlation coefficients (R (2)) larger than 0.9928. The LODs were found to be 20 to 100 nM. Reproducibility of the method was obtained with intra-day and inter-day relative standard deviations (RSDs) less than 10.4 %, and the recoveries in saliva samples ranged from 91.4 to 117.1 %. Taken together, the proposed SIL-BP/ALDI-MS strategy has proved to be a reliable tool for quantitative analysis of aldehydes from complex samples. Graphical Abstract An approach for the determination of small molecules was developed by using black phosphorus (BP) as a matrix-assisted laser desorption ionization (MALDI) matrix.

  5. Rational quality assessment procedure for less-investigated herbal medicines: Case of a Congolese antimalarial drug with an analytical report.

    PubMed

    Tshitenge, Dieudonné Tshitenge; Ioset, Karine Ndjoko; Lami, José Nzunzu; Ndelo-di-Phanzu, Josaphat; Mufusama, Jean-Pierre Koy Sita; Bringmann, Gerhard

    2016-04-01

    Herbal medicines are the most globally used type of medical drugs. Their high cultural acceptability is due to the experienced safety and efficiency over centuries of use. Many of them are still phytochemically less-investigated, and are used without standardization or quality control. Choosing SIROP KILMA, an authorized Congolese antimalarial phytomedicine, as a model case, our study describes an interdisciplinary approach for a rational quality assessment of herbal drugs in general. It combines an authentication step of the herbal remedy prior to any fingerprinting, the isolation of the major constituents, the development and validation of an HPLC-DAD analytical method with internal markers, and the application of the method to several batches of the herbal medicine (here KILMA) thus permitting the establishment of a quantitative fingerprint. From the constitutive plants of KILMA, acteoside, isoacteoside, stachannin A, and pectolinarigenin-7-O-glucoside were isolated, and acteoside was used as the prime marker for the validation of an analytical method. This study contributes to the efforts of the WHO for the establishment of standards enabling the analytical evaluation of herbal materials. Moreover, the paper describes the first phytochemical and analytical report on a marketed Congolese phytomedicine. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Comparability analysis of protein therapeutics by bottom-up LC-MS with stable isotope-tagged reference standards

    PubMed Central

    Manuilov, Anton V; Radziejewski, Czeslaw H

    2011-01-01

    Comparability studies lie at the heart of assessments that evaluate differences amongst manufacturing processes and stability studies of protein therapeutics. Low resolution chromatographic and electrophoretic methods facilitate quantitation, but do not always yield detailed insight into the effect of the manufacturing change or environmental stress. Conversely, mass spectrometry (MS) can provide high resolution information on the molecule, but conventional methods are not very quantitative. This gap can be reconciled by use of a stable isotope-tagged reference standard (SITRS), a version of the analyte protein that is uniformly labeled with 13C6-arginine and 13C6-lysine. The SITRS serves as an internal control that is trypsin-digested and analyzed by liquid chromatography (LC)-MS with the analyte sample. The ratio of the ion intensities of each unlabeled and labeled peptide pair is then compared to that of other sample(s). A comparison of these ratios provides a readily accessible way to spot even minute differences among samples. In a study of a monoclonal antibody (mAb) spiked with varying amounts of the same antibody bearing point mutations, peptides containing the mutations were readily identified and quantified at concentrations as low as 2% relative to unmodified peptides. The method was robust, reproducible and produced a linear response for every peptide that was monitored. The method was also successfully used to distinguish between two batches of a mAb that were produced in two different cell lines while two batches produced from the same cell line were found to be highly comparable. Finally, the use of the SITRS method in the comparison of two stressed mAb samples enabled the identification of sites susceptible to deamidation and oxidation, as well as their quantitation. The experimental results indicate that use of a SITRS in a peptide mapping experiment with MS detection enables sensitive and quantitative comparability studies of proteins at high resolution. PMID:21654206

  7. Comparability analysis of protein therapeutics by bottom-up LC-MS with stable isotope-tagged reference standards.

    PubMed

    Manuilov, Anton V; Radziejewski, Czeslaw H; Lee, David H

    2011-01-01

    Comparability studies lie at the heart of assessments that evaluate differences amongst manufacturing processes and stability studies of protein therapeutics. Low resolution chromatographic and electrophoretic methods facilitate quantitation, but do not always yield detailed insight into the effect of the manufacturing change or environmental stress. Conversely, mass spectrometry (MS) can provide high resolution information on the molecule, but conventional methods are not very quantitative. This gap can be reconciled by use of a stable isotope-tagged reference standard (SITRS), a version of the analyte protein that is uniformly labeled (13)C6-arginine and (13)C6-lysine. The SITRS serves as an internal control that is trypsin-digested and analyzed by liquid chromatography (LC)-MS with the analyte sample. The ratio of the ion intensities of each unlabeled and labeled peptide pair is then compared to that of other sample(s). A comparison of these ratios provides a readily accessible way to spot even minute differences among samples. In a study of a monoclonal antibody (mAb) spiked with varying amounts of the same antibody bearing point mutations, peptides containing the mutations were readily identified and quantified at concentrations as low as 2% relative to unmodified peptides. The method is robust, reproducible and produced a linear response for every peptide that was monitored. The method was also successfully used to distinguish between two batches of a mAb that were produced in two different cell lines while two batches produced from the same cell line were found to be highly comparable. Finally, the use of the SITRS method in the comparison of two stressed mAb samples enabled the identification of sites susceptible to deamidation and oxidation, as well as their quantitation. The experimental results indicate that use of a SITRS in a peptide mapping experiment with MS detection enables sensitive and quantitative comparability studies of proteins at high resolution.

  8. Determination of psilocin, bufotenine, LSD and its metabolites in serum, plasma and urine by SPE-LC-MS/MS.

    PubMed

    Martin, Rafaela; Schürenkamp, Jennifer; Gasse, Angela; Pfeiffer, Heidi; Köhler, Helga

    2013-05-01

    A validated method for the simultaneous determination of psilocin, bufotenine, lysergic acid diethylamide and its metabolites in serum, plasma and urine using liquid chromatography-electrospray ionization/tandem mass spectrometry was developed. During the solid-phase extraction procedure with polymeric mixed-mode cation exchange columns, the unstable analytes were protected by ascorbic acid, drying with nitrogen and exclusion of light. The limits of detection and quantitation for all analytes were low. Recovery was ≥86 % for all analytes and no significant matrix effects were observed. Interday and intraday imprecisions at different concentrations ranged from 1.1 to 8.2 % relative standard deviation, bias was within ±5.3 %. Processed samples were stable in the autosampler for at least 2 days. Furthermore, freeze/thaw and long-term stability were investigated. The method was successfully applied to authentic serum and urine samples.

  9. [Determination of five naphthaquinones in Arnebia euchroma by quantitative analysis multi-components with single-marker].

    PubMed

    Zhao, Wen-Wen; Wu, Zhi-Min; Wu, Xia; Zhao, Hai-Yu; Chen, Xiao-Qing

    2016-10-01

    This study is to determine five naphthaquinones (acetylshikonin, β-acetoxyisovalerylalkannin, isobutylshikonin, β,β'-dimethylacrylalkannin,α-methyl-n-butylshikonin) by quantitative analysis of multi-components with a single marker (QAMS). β,β'-Dimethylacrylalkannin was selected as the internal reference substance, and the relative correlation factors (RCFs) of acetylshikonin, β-acetoxyisovalerylalkannin, isobutylshikonin and α-methyl-n-butylshikonin were calculated. Then the ruggedness of relative correction factors was tested on different instruments and columns. Meanwhile, 16 batches of Arnebia euchroma were analyzed by external standard method (ESM) and QAMS, respectively. The peaks were identifited by LC-MS. The ruggedness of relative correction factors was good. And the analytical results calculated by ESM and QAMS showed no difference. The quantitative method established was feasible and suitable for the quality evaluation of A. euchroma. Copyright© by the Chinese Pharmaceutical Association.

  10. Sampling of illicit drugs for quantitative analysis--part II. Study of particle size and its influence on mass reduction.

    PubMed

    Bovens, M; Csesztregi, T; Franc, A; Nagy, J; Dujourdy, L

    2014-01-01

    The basic goal in sampling for the quantitative analysis of illicit drugs is to maintain the average concentration of the drug in the material from its original seized state (the primary sample) all the way through to the analytical sample, where the effect of particle size is most critical. The size of the largest particles of different authentic illicit drug materials, in their original state and after homogenisation, using manual or mechanical procedures, was measured using a microscope with a camera attachment. The comminution methods employed included pestle and mortar (manual) and various ball and knife mills (mechanical). The drugs investigated were amphetamine, heroin, cocaine and herbal cannabis. It was shown that comminution of illicit drug materials using these techniques reduces the nominal particle size from approximately 600 μm down to between 200 and 300 μm. It was demonstrated that the choice of 1 g increments for the primary samples of powdered drugs and cannabis resin, which were used in the heterogeneity part of our study (Part I) was correct for the routine quantitative analysis of illicit seized drugs. For herbal cannabis we found that the appropriate increment size was larger. Based on the results of this study we can generally state that: An analytical sample weight of between 20 and 35 mg of an illicit powdered drug, with an assumed purity of 5% or higher, would be considered appropriate and would generate an RSDsampling in the same region as the RSDanalysis for a typical quantitative method of analysis for the most common, powdered, illicit drugs. For herbal cannabis, with an assumed purity of 1% THC (tetrahydrocannabinol) or higher, an analytical sample weight of approximately 200 mg would be appropriate. In Part III we will pull together our homogeneity studies and particle size investigations and use them to devise sampling plans and sample preparations suitable for the quantitative instrumental analysis of the most common illicit drugs. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  11. Adaptable Detection Strategies in Membrane-Based Immunoassays: Calibration-Free Quantitation with Surface-Enhanced Raman Scattering Readout.

    PubMed

    Skuratovsky, Aleksander; Soto, Robert J; Porter, Marc D

    2018-06-19

    This paper presents a method for immunometric biomarker quantitation that uses standard flow-through assay reagents and obviates the need for constructing a calibration curve. The approach relies on a nitrocellulose immunoassay substrate with multiple physical addresses for analyte capture, each modified with different amounts of an analyte-specific capture antibody. As such, each address generates a distinctly different readout signal that is proportional to the analyte concentration in the sample. To establish the feasibility of this concept, equations derived from antibody-antigen binding equilibrium were first applied in modeling experiments. Next, nitrocellulose membranes with multiple capture antibody addresses were fabricated for detection of a model analyte, human Immunoglobulin G (hIgG), by a heterogeneous sandwich immunoassay using antibody-modified gold nanoparticles (AuNPs) as the immunolabel. Counting the number of colored capture addresses visible to the unassisted eye enabled semiquantitative hIgG determination. We then demonstrated that, by leveraging the localized surface plasmon resonance of the AuNPs, surface-enhanced Raman spectroscopy (SERS) can be used for quantitative readout. By comparing the SERS signal intensities from each capture address with values predicted using immunoassay equilibrium theory, the concentration of hIgG can be determined (∼30% average absolute deviation) without reference to a calibration curve. This work also demonstrates the ability to manipulate the dynamic range of the assay over ∼4 orders of magnitude (from 2 ng mL -1 to 10 μg mL -1 ). The potential prospects in applying this concept to point-of-need diagnostics are also discussed.

  12. Method of assessing a lipid-related health risk based on ion mobility analysis of lipoproteins

    DOEpatents

    Benner, W. Henry; Krauss, Ronald M.; Blanche, Patricia J.

    2010-12-14

    A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.

  13. Development of Validated Bioanalytical HPLC-UV Method for Simultaneous Estimation of Amlodipine and Atorvastatin in Rat Plasma

    PubMed Central

    Talele, G. S.; Porwal, P. K.

    2015-01-01

    A simple, economical and robust analytical high-performance liquid chromatography-ultraviolet method was developed and validated for simultaneous chromatographic elution of two cardiovascular drugs viz. amlodipine and atorvastatin in biological fluid for the first time. Only two liquid chromatography–mass spectrometry/mass spectrometry methods are available in literature for quantitation of selected pair of analytes. The bioanalytical method was developed in rat plasma by using Thermo beta-basic C18 (100×4.6 mm, 5 μm) and mobile phase was composed of dibasic phosphate buffer (pH 3.0):acetonitrile in the ratio of 55:45 at a flow rate of 1 ml/min with ultraviolet detection monitored at 240 nm. The selected chromatographic conditions were found to effectively separate amlodipine (5.1 min) and atorvastatin (12.1 min). The parametric statistics,i.e. correlation coefficient of 0.999, was assessed for both the drugs having linearity over the tested concentration range (0.05 to 10.0 μg/ml) in rat plasma using an unweighted calibration curve. The mean recovery (%) was more than 92.8% for both the drugs using protein precipitation method. The accuracy of samples for six replicate measurements at lower limit of quantitation level was within limit. The method was validated and was successfully applied to the nonclinical pharmacokinetic study of combination tablets containing amlodipine and atorvastatin in six Sprague Dawley rats. PMID:26997703

  14. Determining the risk of cardiovascular disease using ion mobility of lipoproteins

    DOEpatents

    Benner, W. Henry; Krauss, Ronald M.; Blanche, Patricia J.

    2010-05-11

    A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.

  15. An improved method to measure nitrate/nitrite with an NO-selective electrochemical sensor

    PubMed Central

    Boo, Yong Chool; Tressel, Sarah L.; Jo, Hanjoong

    2007-01-01

    Nitric oxide produced from nitric oxide synthase(s) is an important cell signaling molecule in physiology and pathophysiology. In the present study, we describe a very sensitive and convenient analytical method to measure NOx (nitrite plus nitrate) in culture media by employing an ultra-sensitive nitric oxide-selective electrochemical sensor which became commercially available recently. An aliquot of conditioned culture media was first treated with nitrate reductase/NADPH/glucose-6-phosphate dehydrogenase/glucose-6-phosphate to convert nitrate to nitrite quantitatively. The nitrite (that is present originally plus the reduced nitrate) was then reduced to equimolar NO in an acidic iodide bath while NO was being detected by the sensor. This analytical method appears to be very useful to assess basal and stimulated NO release from cultured cells. PMID:17056288

  16. Semi-automated solid phase extraction method for the mass spectrometric quantification of 12 specific metabolites of organophosphorus pesticides, synthetic pyrethroids, and select herbicides in human urine.

    PubMed

    Davis, Mark D; Wade, Erin L; Restrepo, Paula R; Roman-Esteva, William; Bravo, Roberto; Kuklenyik, Peter; Calafat, Antonia M

    2013-06-15

    Organophosphate and pyrethroid insecticides and phenoxyacetic acid herbicides represent important classes of pesticides applied in commercial and residential settings. Interest in assessing the extent of human exposure to these pesticides exists because of their widespread use and their potential adverse health effects. An analytical method for measuring 12 biomarkers of several of these pesticides in urine has been developed. The target analytes were extracted from one milliliter of urine by a semi-automated solid phase extraction technique, separated from each other and from other urinary biomolecules by reversed-phase high performance liquid chromatography, and detected using tandem mass spectrometry with isotope dilution quantitation. This method can be used to measure all the target analytes in one injection with similar repeatability and detection limits of previous methods which required more than one injection. Each step of the procedure was optimized to produce a robust, reproducible, accurate, precise and efficient method. The required selectivity and sensitivity for trace-level analysis (e.g., limits of detection below 0.5ng/mL) was achieved using a narrow diameter analytical column, higher than unit mass resolution for certain analytes, and stable isotope labeled internal standards. The method was applied to the analysis of 55 samples collected from adult anonymous donors with no known exposure to the target pesticides. This efficient and cost-effective method is adequate to handle the large number of samples required for national biomonitoring surveys. Published by Elsevier B.V.

  17. Liquid chromatographic determination of sennosides in Cassia angustifolia leaves.

    PubMed

    Srivastava, Alpuna; Pandey, Richa; Verma, Ram K; Gupta, Madan M

    2006-01-01

    A simple liquid chromatographic method was developed for the determination of sennosides B and A in leaves of Cassia angustifolia. These compounds were extracted from leaves with a mixture of methanol-water (70 + 30, v/v) after defatting with hexane. Analyte separation and quantitation were achieved by gradient reversed-phase liquid chromatography and UV absorbance at 270 nm using a photodiode array detector. The method involves the use of an RP-18 Lichrocart reversed-phase column (5 microm, 125 x 4.0 mm id) and a binary gradient mobile-phase profile. The various other aspects of analysis, namely, peak purity, similarity, recovery, repeatability, and robustness, were validated. Average recoveries of 98.5 and 98.6%, with a coefficient of variation of 0.8 and 0.3%, were obtained by spiking sample solution with 3 different concentration solutions of standards (60, 100, and 200 microg/mL). Detection limits were 10 microg/mL for sennoside B and 35 microg/mL for sennoside A, present in the sample solution. The quantitation limits were 28 and 100 microg/mL. The analytical method was applied to a large number of senna leaf samples. The new method provides a reliable tool for rapid screening of C. angustifolia samples in large numbers, which is needed in breeding/genetic engineering and genetic mapping experiments.

  18. Multivariate calibration in Laser-Induced Breakdown Spectroscopy quantitative analysis: The dangers of a 'black box' approach and how to avoid them

    NASA Astrophysics Data System (ADS)

    Safi, A.; Campanella, B.; Grifoni, E.; Legnaioli, S.; Lorenzetti, G.; Pagnotta, S.; Poggialini, F.; Ripoll-Seguer, L.; Hidalgo, M.; Palleschi, V.

    2018-06-01

    The introduction of multivariate calibration curve approach in Laser-Induced Breakdown Spectroscopy (LIBS) quantitative analysis has led to a general improvement of the LIBS analytical performances, since a multivariate approach allows to exploit the redundancy of elemental information that are typically present in a LIBS spectrum. Software packages implementing multivariate methods are available in the most diffused commercial and open source analytical programs; in most of the cases, the multivariate algorithms are robust against noise and operate in unsupervised mode. The reverse of the coin of the availability and ease of use of such packages is the (perceived) difficulty in assessing the reliability of the results obtained which often leads to the consideration of the multivariate algorithms as 'black boxes' whose inner mechanism is supposed to remain hidden to the user. In this paper, we will discuss the dangers of a 'black box' approach in LIBS multivariate analysis, and will discuss how to overcome them using the chemical-physical knowledge that is at the base of any LIBS quantitative analysis.

  19. In-focal-plane characterization of excitation distribution for quantitative fluorescence microscopy applications

    NASA Astrophysics Data System (ADS)

    Dietrich, Klaus; Brülisauer, Martina; ćaǧin, Emine; Bertsch, Dietmar; Lüthi, Stefan; Heeb, Peter; Stärker, Ulrich; Bernard, André

    2017-06-01

    The applications of fluorescence microscopy span medical diagnostics, bioengineering and biomaterial analytics. Full exploitation of fluorescent microscopy is hampered by imperfections in illumination, detection and filtering. Mainly, errors stem from deviations induced by real-world components inducing spatial or angular variations of propagation properties along the optical path, and they can be addressed through consistent and accurate calibration. For many applications, uniform signal to noise ratio (SNR) over the imaging area is required. Homogeneous SNR can be achieved by quantifying and compensating for the signal bias. We present a method to quantitatively characterize novel reference materials as a calibration reference for biomaterials analytics. The reference materials under investigation comprise thin layers of fluorophores embedded in polymer matrices. These layers are highly homogeneous in their fluorescence response, where cumulative variations do not exceed 1% over the field of view (1.5 x 1.1 mm). An automated and reproducible measurement methodology, enabling sufficient correction for measurement artefacts, is reported. The measurement setup is equipped with an autofocus system, ensuring that the measured film quality is not artificially increased by out-of-focus reduction of the system modulation transfer function. The quantitative characterization method is suitable for analysis of modified bio-materials, especially through patterned protein decoration. The imaging method presented here can be used to statistically analyze protein patterns, thereby increasing both precision and throughput. Further, the method can be developed to include a reference emitter and detector pair on the image surface of the reference object, in order to provide traceable measurements.

  20. Modeling Dynamic Functional Neuroimaging Data Using Structural Equation Modeling

    ERIC Educational Resources Information Center

    Price, Larry R.; Laird, Angela R.; Fox, Peter T.; Ingham, Roger J.

    2009-01-01

    The aims of this study were to present a method for developing a path analytic network model using data acquired from positron emission tomography. Regions of interest within the human brain were identified through quantitative activation likelihood estimation meta-analysis. Using this information, a "true" or population path model was then…

  1. OVERVIEW OF A NEW EPA METHOD: DETERMINATION OF PERCHLORATE IN DRINKING WATER, GROUNDWATER AND HIGH SALINITY WATER BY ION CHROMATOGRAPHY, SUPPRESSED CONDUCTIVITY WITH ELECTROSPRAY IONIZATION MASS SPECTROMETRIC DETECTION

    EPA Science Inventory

    In this presentation the analytical instrumentation and procedures necessary to qualitatively and quantitatively determine low levels of perchlorate (ClO4-) in drinking waters using ion chromatography with electrolytic conductivity suppression, electrospray ionization mass spec...

  2. Making and Using a Sensing Polymeric Material for Cu[superscript 2+

    ERIC Educational Resources Information Center

    Paddock, Jean R.; Maghasi, Anne T.; Heineman, William R.; Seliskar, Carl J.

    2005-01-01

    A simple chemical sensor-related experiment rooted in the synthesis of polymeric materials for use in either an advanced high-school or undergraduate college laboratory is presented. Students are introduced to and combine to the concepts of the chemical sensor, polymer chemistry, spectroscopy, metal chelates, and quantitative analytical methods.

  3. Transitioning from Targeted to Comprehensive Mass Spectrometry Using Genetic Algorithms.

    PubMed

    Jaffe, Jacob D; Feeney, Caitlin M; Patel, Jinal; Lu, Xiaodong; Mani, D R

    2016-11-01

    Targeted proteomic assays are becoming increasingly popular because of their robust quantitative applications enabled by internal standardization, and they can be routinely executed on high performance mass spectrometry instrumentation. However, these assays are typically limited to 100s of analytes per experiment. Considerable time and effort are often expended in obtaining and preparing samples prior to targeted analyses. It would be highly desirable to detect and quantify 1000s of analytes in such samples using comprehensive mass spectrometry techniques (e.g., SWATH and DIA) while retaining a high degree of quantitative rigor for analytes with matched internal standards. Experimentally, it is facile to port a targeted assay to a comprehensive data acquisition technique. However, data analysis challenges arise from this strategy concerning agreement of results from the targeted and comprehensive approaches. Here, we present the use of genetic algorithms to overcome these challenges in order to configure hybrid targeted/comprehensive MS assays. The genetic algorithms are used to select precursor-to-fragment transitions that maximize the agreement in quantification between the targeted and the comprehensive methods. We find that the algorithm we used provided across-the-board improvement in the quantitative agreement between the targeted assay data and the hybrid comprehensive/targeted assay that we developed, as measured by parameters of linear models fitted to the results. We also found that the algorithm could perform at least as well as an independently-trained mass spectrometrist in accomplishing this task. We hope that this approach will be a useful tool in the development of quantitative approaches for comprehensive proteomics techniques. Graphical Abstract ᅟ.

  4. Transitioning from Targeted to Comprehensive Mass Spectrometry Using Genetic Algorithms

    NASA Astrophysics Data System (ADS)

    Jaffe, Jacob D.; Feeney, Caitlin M.; Patel, Jinal; Lu, Xiaodong; Mani, D. R.

    2016-11-01

    Targeted proteomic assays are becoming increasingly popular because of their robust quantitative applications enabled by internal standardization, and they can be routinely executed on high performance mass spectrometry instrumentation. However, these assays are typically limited to 100s of analytes per experiment. Considerable time and effort are often expended in obtaining and preparing samples prior to targeted analyses. It would be highly desirable to detect and quantify 1000s of analytes in such samples using comprehensive mass spectrometry techniques (e.g., SWATH and DIA) while retaining a high degree of quantitative rigor for analytes with matched internal standards. Experimentally, it is facile to port a targeted assay to a comprehensive data acquisition technique. However, data analysis challenges arise from this strategy concerning agreement of results from the targeted and comprehensive approaches. Here, we present the use of genetic algorithms to overcome these challenges in order to configure hybrid targeted/comprehensive MS assays. The genetic algorithms are used to select precursor-to-fragment transitions that maximize the agreement in quantification between the targeted and the comprehensive methods. We find that the algorithm we used provided across-the-board improvement in the quantitative agreement between the targeted assay data and the hybrid comprehensive/targeted assay that we developed, as measured by parameters of linear models fitted to the results. We also found that the algorithm could perform at least as well as an independently-trained mass spectrometrist in accomplishing this task. We hope that this approach will be a useful tool in the development of quantitative approaches for comprehensive proteomics techniques.

  5. A validated UHPLC-tandem mass spectrometry method for quantitative analysis of flavonolignans in milk thistle (Silybum marianum) extracts.

    PubMed

    Graf, Tyler N; Cech, Nadja B; Polyak, Stephen J; Oberlies, Nicholas H

    2016-07-15

    Validated methods are needed for the analysis of natural product secondary metabolites. These methods are particularly important to translate in vitro observations to in vivo studies. Herein, a method is reported for the analysis of the key secondary metabolites, a series of flavonolignans and a flavonoid, from an extract prepared from the seeds of milk thistle [Silybum marianum (L.) Gaertn. (Asteraceae)]. This report represents the first UHPLC MS-MS method validated for quantitative analysis of these compounds. The method takes advantage of the excellent resolution achievable with UHPLC to provide a complete analysis in less than 7min. The method is validated using both UV and MS detectors, making it applicable in laboratories with different types of analytical instrumentation available. Lower limits of quantitation achieved with this method range from 0.0400μM to 0.160μM with UV and from 0.0800μM to 0.160μM with MS. The new method is employed to evaluate variability in constituent composition in various commercial S. marianum extracts, and to show that storage of the milk thistle compounds in DMSO leads to degradation. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Precise determination of N-acetylcysteine in pharmaceuticals by microchip electrophoresis.

    PubMed

    Rudašová, Marína; Masár, Marián

    2016-01-01

    A novel microchip electrophoresis method for the rapid and high-precision determination of N-acetylcysteine, a pharmaceutically active ingredient, in mucolytics has been developed. Isotachophoresis separations were carried out at pH 6.0 on a microchip with conductivity detection. The methods of external calibration and internal standard were used to evaluate the results. The internal standard method effectively eliminated variations in various working parameters, mainly run-to-run fluctuations of an injected volume. The repeatability and accuracy of N-acetylcysteine determination in all mucolytic preparations tested (Solmucol 90 and 200, and ACC Long 600) were more than satisfactory with the relative standard deviation and relative error values <0.7 and <1.9%, respectively. A recovery range of 99-101% of N-acetylcysteine in the analyzed pharmaceuticals predetermines the proposed method for accurate analysis as well. This work, in general, indicates analytical possibilities of microchip isotachophoresis for the quantitative analysis of simplified samples such as pharmaceuticals that contain the analyte(s) at relatively high concentrations. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Nonesterified fatty acid determination for functional lipidomics: comprehensive ultrahigh performance liquid chromatography-tandem mass spectrometry quantitation, qualification, and parameter prediction.

    PubMed

    Hellmuth, Christian; Weber, Martina; Koletzko, Berthold; Peissner, Wolfgang

    2012-02-07

    Despite their central importance for lipid metabolism, straightforward quantitative methods for determination of nonesterified fatty acid (NEFA) species are still missing. The protocol presented here provides unbiased quantitation of plasma NEFA species by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Simple deproteination of plasma in organic solvent solution yields high accuracy, including both the unbound and initially protein-bound fractions, while avoiding interferences from hydrolysis of esterified fatty acids from other lipid classes. Sample preparation is fast and nonexpensive, hence well suited for automation and high-throughput applications. Separation of isotopologic NEFA is achieved using ultrahigh-performance liquid chromatography (UPLC) coupled to triple quadrupole LC-MS/MS detection. In combination with automated liquid handling, total assay time per sample is less than 15 min. The analytical spectrum extends beyond readily available NEFA standard compounds by a regression model predicting all the relevant analytical parameters (retention time, ion path settings, and response factor) of NEFA species based on chain length and number of double bonds. Detection of 50 NEFA species and accurate quantification of 36 NEFA species in human plasma is described, the highest numbers ever reported for a LC-MS application. Accuracy and precision are within widely accepted limits. The use of qualifier ions supports unequivocal analyte verification. © 2012 American Chemical Society

  8. LC-MS/MS method development for quantitative analysis of acetaminophen uptake by the aquatic fungus Mucor hiemalis.

    PubMed

    Esterhuizen-Londt, Maranda; Schwartz, Katrin; Balsano, Evelyn; Kühn, Sandra; Pflugmacher, Stephan

    2016-06-01

    Acetaminophen is a pharmaceutical, frequently found in surface water as a contaminant. Bioremediation, in particular, mycoremediation of acetaminophen is a method to remove this compound from waters. Owing to the lack of quantitative analytical method for acetaminophen in aquatic organisms, the present study aimed to develop a method for the determination of acetaminophen using LC-MS/MS in the aquatic fungus Mucor hiemalis. The method was then applied to evaluate the uptake of acetaminophen by M. hiemalis, cultured in pellet morphology. The method was robust, sensitive and reproducible with a lower limit of quantification of 5 pg acetaminophen on column. It was found that M. hiemalis internalize the pharmaceutical, and bioaccumulate it with time. Therefore, M. hiemalis was deemed a suitable candidate for further studies to elucidate its pharmaceutical tolerance and the longevity in mycoremediation applications. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. A double-taper optical fiber-based radiation wave other than evanescent wave in all-fiber immunofluorescence biosensor for quantitative detection of Escherichia coli O157:H7.

    PubMed

    Zhang, Zhonghuan; Hua, Fei; Liu, Ting; Zhao, Yong; Li, Jun; Yang, Ruifu; Yang, Changxi; Zhou, Lei

    2014-01-01

    Cylindrical or taper-and-cylinder combination optical fiber probe based on evanescent wave has been widely used for immunofluorescence biosensor to detect various analytes. In this study, in contrast to the contradiction between penetration depth and analyte diameter of optical fiber probe-based evanescent wave, we demonstrate that double-taper optical fiber used in a radiation wave-based all-fiber immunofluorescence biosensor (RWAIB) can detect micron-scale analytes using Escherichia coli O157:H7 as representative target. Finite-difference time-domain method was used to compare the properties of evanescent wave and radiation wave (RW). Ray-tracing model was formulated to optimize the taper geometry of the probe. Based on a commercial multi-mode fiber, a double-taper probe was fabricated and connected with biosensor through a "ferrule connector" optical fiber connector. The RWAIB configuration was accomplished using commercial multi-mode fibers and fiber-based devices according to the "all-fiber" method. The standard sample tests revealed that the sensitivity of the proposed technique for E. coli O157:H7 detection was 10(3) cfu · mL(-1). Quantitation could be achieved within the concentration range of 10(3) cfu · mL(-1) to 107 cfu · mL(-1). No non-specific recognition to ten kinds of food-borne pathogens was observed. The results demonstrated that based on the double-taper optical fiber RWAIB can be used for the quantitative detection of micron-scale targets, and RW sensing is an alternative for traditional evanescent wave sensing during the fabrication of fiber-optic biosensors.

  10. Rapid perfusion quantification using Welch-Satterthwaite approximation and analytical spectral filtering

    NASA Astrophysics Data System (ADS)

    Krishnan, Karthik; Reddy, Kasireddy V.; Ajani, Bhavya; Yalavarthy, Phaneendra K.

    2017-02-01

    CT and MR perfusion weighted imaging (PWI) enable quantification of perfusion parameters in stroke studies. These parameters are calculated from the residual impulse response function (IRF) based on a physiological model for tissue perfusion. The standard approach for estimating the IRF is deconvolution using oscillatory-limited singular value decomposition (oSVD) or Frequency Domain Deconvolution (FDD). FDD is widely recognized as the fastest approach currently available for deconvolution of CT Perfusion/MR PWI. In this work, three faster methods are proposed. The first is a direct (model based) crude approximation to the final perfusion quantities (Blood flow, Blood volume, Mean Transit Time and Delay) using the Welch-Satterthwaite approximation for gamma fitted concentration time curves (CTC). The second method is a fast accurate deconvolution method, we call Analytical Fourier Filtering (AFF). The third is another fast accurate deconvolution technique using Showalter's method, we call Analytical Showalter's Spectral Filtering (ASSF). Through systematic evaluation on phantom and clinical data, the proposed methods are shown to be computationally more than twice as fast as FDD. The two deconvolution based methods, AFF and ASSF, are also shown to be quantitatively accurate compared to FDD and oSVD.

  11. Haze Gray Paint and the U.S. Navy: A Procurement Process Review

    DTIC Science & Technology

    2017-12-01

    support of the fleet. The research encompasses both qualitative and quantitative analytical tools utilizing historical demand data for Silicone Alkyd...inventory level of 1K Polysiloxane in support of the fleet. The research encompasses both qualitative and quantitative analytical tools utilizing...Chapter I. C. CONCLUSIONS As discussed in the Summary section, this research used a qualitative and a quantitative approach to analyze the Polysiloxane

  12. Application of adenosine triphosphate affinity probe and scheduled multiple-reaction monitoring analysis for profiling global kinome in human cells in response to arsenite treatment.

    PubMed

    Guo, Lei; Xiao, Yongsheng; Wang, Yinsheng

    2014-11-04

    Phosphorylation of cellular components catalyzed by kinases plays important roles in cell signaling and proliferation. Quantitative assessment of perturbation in global kinome may provide crucial knowledge for elucidating the mechanisms underlying the cytotoxic effects of environmental toxicants. Here, we utilized an adenosine triphosphate (ATP) affinity probe coupled with stable isotope labeling by amino acids in cell culture (SILAC) to assess quantitatively the arsenite-induced alteration of global kinome in human cells. We constructed a SILAC-compatible kinome library for scheduled multiple-reaction monitoring (MRM) analysis and adopted on-the-fly recalibration of retention time shift, which provided better throughput of the analytical method and enabled the simultaneous quantification of the expression of ∼300 kinases in two LC-MRM runs. With this improved analytical method, we conducted an in-depth quantitative analysis of the perturbation of kinome of GM00637 human skin fibroblast cells induced by arsenite exposure. Several kinases involved in cell cycle progression, including cyclin-dependent kinases (CDK1 and CDK4) and Aurora kinases A, B, and C, were found to be hyperactivated, and the altered expression of CDK1 was further validated by Western analysis. In addition, treatment with a CDK inhibitor, flavopiridol, partially restored the arsenite-induced growth inhibition of human skin fibroblast cells. Thus, sodium arsenite may confer its cytotoxic effect partly through the aberrant activation of CDKs and the resultant perturbation of cell cycle progression. Together, we developed a high-throughput, SILAC-compatible, and MRM-based kinome profiling method and demonstrated that the method is powerful in deciphering the molecular modes of action of a widespread environmental toxicant. The method should be generally applicable for uncovering the cellular pathways triggered by other extracellular stimuli.

  13. Application of Adenosine Triphosphate Affinity Probe and Scheduled Multiple-Reaction Monitoring Analysis for Profiling Global Kinome in Human Cells in Response to Arsenite Treatment

    PubMed Central

    2015-01-01

    Phosphorylation of cellular components catalyzed by kinases plays important roles in cell signaling and proliferation. Quantitative assessment of perturbation in global kinome may provide crucial knowledge for elucidating the mechanisms underlying the cytotoxic effects of environmental toxicants. Here, we utilized an adenosine triphosphate (ATP) affinity probe coupled with stable isotope labeling by amino acids in cell culture (SILAC) to assess quantitatively the arsenite-induced alteration of global kinome in human cells. We constructed a SILAC-compatible kinome library for scheduled multiple-reaction monitoring (MRM) analysis and adopted on-the-fly recalibration of retention time shift, which provided better throughput of the analytical method and enabled the simultaneous quantification of the expression of ∼300 kinases in two LC-MRM runs. With this improved analytical method, we conducted an in-depth quantitative analysis of the perturbation of kinome of GM00637 human skin fibroblast cells induced by arsenite exposure. Several kinases involved in cell cycle progression, including cyclin-dependent kinases (CDK1 and CDK4) and Aurora kinases A, B, and C, were found to be hyperactivated, and the altered expression of CDK1 was further validated by Western analysis. In addition, treatment with a CDK inhibitor, flavopiridol, partially restored the arsenite-induced growth inhibition of human skin fibroblast cells. Thus, sodium arsenite may confer its cytotoxic effect partly through the aberrant activation of CDKs and the resultant perturbation of cell cycle progression. Together, we developed a high-throughput, SILAC-compatible, and MRM-based kinome profiling method and demonstrated that the method is powerful in deciphering the molecular modes of action of a widespread environmental toxicant. The method should be generally applicable for uncovering the cellular pathways triggered by other extracellular stimuli. PMID:25301106

  14. Precise quantitation of 136 urinary proteins by LC/MRM-MS using stable isotope labeled peptides as internal standards for biomarker discovery and/or verification studies.

    PubMed

    Percy, Andrew J; Yang, Juncong; Hardie, Darryl B; Chambers, Andrew G; Tamura-Wells, Jessica; Borchers, Christoph H

    2015-06-15

    Spurred on by the growing demand for panels of validated disease biomarkers, increasing efforts have focused on advancing qualitative and quantitative tools for more highly multiplexed and sensitive analyses of a multitude of analytes in various human biofluids. In quantitative proteomics, evolving strategies involve the use of the targeted multiple reaction monitoring (MRM) mode of mass spectrometry (MS) with stable isotope-labeled standards (SIS) used for internal normalization. Using that preferred approach with non-invasive urine samples, we have systematically advanced and rigorously assessed the methodology toward the precise quantitation of the largest, multiplexed panel of candidate protein biomarkers in human urine to date. The concentrations of the 136 proteins span >5 orders of magnitude (from 8.6 μg/mL to 25 pg/mL), with average CVs of 8.6% over process triplicate. Detailed here is our quantitative method, the analysis strategy, a feasibility application to prostate cancer samples, and a discussion of the utility of this method in translational studies. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Combination of nano-material enrichment and dead-end filtration for uniform and rapid sample preparation in matrix-assisted laser desorption/ionization mass spectrometry.

    PubMed

    Wu, Zengnan; Khan, Mashooq; Mao, Sifeng; Lin, Ling; Lin, Jin-Ming

    2018-05-01

    Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is a fast analysis tool for the detection of a wide range of analytes. However, heterogeneous distribution of matrix/analyte cocrystal, variation in signal intensity and poor experimental reproducibility at different locations of the same spot means difficulty in quantitative analysis. In this work, carbon nanotubes (CNTs) were employed as adsorbent for analyte cum matrix on a conductive porous membrane as a novel mass target plate. The sample pretreatment step was achieved by enrichment and dead-end filtration and dried by a solid-liquid separation. This approach enables the homogeneous distribution of analyte in the matrix, good shot-to-shot reproducibility in signals and quantitative detection of peptide and protein at different concentrations with correlation coefficient (R 2 ) of 0.9920 and 0.9909, respectively. The simple preparation of sample in a short time, uniform distribution of analyte, easy quantitative detection, and high reproducibility makes this technique useful and may diversify the application of MALDI-MS for quantitative detection of a variety of proteins. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Development of a method for the determination of 9 currently used cotton pesticides by gas chromatography with electron capture detection.

    PubMed

    Zhang, Baohong; Pan, Xiaoping; Venne, Louise; Dunnum, Suzy; McMurry, Scott T; Cobb, George P; Anderson, Todd A

    2008-05-30

    A reliable, sensitive, and reproducible method was developed for quantitative determination of nine new generation pesticides currently used in cotton agriculture. Injector temperature significantly affected analyte response as indicated by electron capture detector (ECD) chromatograms. A majority of the analytes had an enhanced response at injector temperatures between 240 and 260 degrees C, especially analytes such as acephate that overall had a poor response on the ECD. The method detection limits (MDLs) were 0.13, 0.05, 0.29, 0.35, 0.08, 0.10, 0.32, 0.05, and 0.59 ng/mL for acephate, trifuralin, malathion, thiamethozam, pendimethalin, DEF6, acetamiprid, brifenthrin, and lambda-cyhalothrin. This study provides a precision (0.17-13.1%), accuracy (recoveries=88-107%) and good reproducible method for the analytes of interest. At relatively high concentrations, only lambda-cyhalothrin was unstable at room temperature (20-25 degrees C) and 4 degrees C over 10 days. At relatively low concentrations, acephate and acetamiprid were also unstable regardless of temperature. After 10 days storage at room temperature, 30-40% degradation of lambda-cyhalothrin was observed. It is recommended that acephate, acetamiprid, and lambda-cyhalothrin be stored at -20 degrees C or analyzed immediately after extraction.

  17. A New Green Method for the Quantitative Analysis of Enrofloxacin by Fourier-Transform Infrared Spectroscopy.

    PubMed

    Rebouças, Camila Tavares; Kogawa, Ana Carolina; Salgado, Hérida Regina Nunes

    2018-05-18

    Background: A green analytical chemistry method was developed for quantification of enrofloxacin in tablets. The drug, a second-generation fluoroquinolone, was first introduced in veterinary medicine for the treatment of various bacterial species. Objective: This study proposed to develop, validate, and apply a reliable, low-cost, fast, and simple IR spectroscopy method for quantitative routine determination of enrofloxacin in tablets. Methods: The method was completely validated according to the International Conference on Harmonisation guidelines, showing accuracy, precision, selectivity, robustness, and linearity. Results: It was linear over the concentration range of 1.0-3.0 mg with correlation coefficients >0.9999 and LOD and LOQ of 0.12 and 0.36 mg, respectively. Conclusions: Now that this IR method has met performance qualifications, it can be adopted and applied for the analysis of enrofloxacin tablets for production process control. The validated method can also be utilized to quantify enrofloxacin in tablets and thus is an environmentally friendly alternative for the routine analysis of enrofloxacin in quality control. Highlights: A new green method for the quantitative analysis of enrofloxacin by Fourier-Transform Infrared spectroscopy was validated. It is a fast, clean and low-cost alternative for the evaluation of enrofloxacin tablets.

  18. Reagentless, Structure-Switching, Electrochemical Aptamer-Based Sensors

    NASA Astrophysics Data System (ADS)

    Schoukroun-Barnes, Lauren R.; Macazo, Florika C.; Gutierrez, Brenda; Lottermoser, Justine; Liu, Juan; White, Ryan J.

    2016-06-01

    The development of structure-switching, electrochemical, aptamer-based sensors over the past ˜10 years has led to a variety of reagentless sensors capable of analytical detection in a range of sample matrices. The crux of this methodology is the coupling of target-induced conformation changes of a redox-labeled aptamer with electrochemical detection of the resulting altered charge transfer rate between the redox molecule and electrode surface. Using aptamer recognition expands the highly sensitive detection ability of electrochemistry to a range of previously inaccessible analytes. In this review, we focus on the methods of sensor fabrication and how sensor signaling is affected by fabrication parameters. We then discuss recent studies addressing the fundamentals of sensor signaling as well as quantitative characterization of the analytical performance of electrochemical aptamer-based sensors. Although the limits of detection of reported electrochemical aptamer-based sensors do not often reach that of gold-standard methods such as enzyme-linked immunosorbent assays, the operational convenience of the sensor platform enables exciting analytical applications that we address. Using illustrative examples, we highlight recent advances in the field that impact important areas of analytical chemistry. Finally, we discuss the challenges and prospects for this class of sensors.

  19. Analyzing chromatographic data using multilevel modeling.

    PubMed

    Wiczling, Paweł

    2018-06-01

    It is relatively easy to collect chromatographic measurements for a large number of analytes, especially with gradient chromatographic methods coupled with mass spectrometry detection. Such data often have a hierarchical or clustered structure. For example, analytes with similar hydrophobicity and dissociation constant tend to be more alike in their retention than a randomly chosen set of analytes. Multilevel models recognize the existence of such data structures by assigning a model for each parameter, with its parameters also estimated from data. In this work, a multilevel model is proposed to describe retention time data obtained from a series of wide linear organic modifier gradients of different gradient duration and different mobile phase pH for a large set of acids and bases. The multilevel model consists of (1) the same deterministic equation describing the relationship between retention time and analyte-specific and instrument-specific parameters, (2) covariance relationships relating various physicochemical properties of the analyte to chromatographically specific parameters through quantitative structure-retention relationship based equations, and (3) stochastic components of intra-analyte and interanalyte variability. The model was implemented in Stan, which provides full Bayesian inference for continuous-variable models through Markov chain Monte Carlo methods. Graphical abstract Relationships between log k and MeOH content for acidic, basic, and neutral compounds with different log P. CI credible interval, PSA polar surface area.

  20. Photogrammetry Applied to Wind Tunnel Testing

    NASA Technical Reports Server (NTRS)

    Liu, Tian-Shu; Cattafesta, L. N., III; Radeztsky, R. H.; Burner, A. W.

    2000-01-01

    In image-based measurements, quantitative image data must be mapped to three-dimensional object space. Analytical photogrammetric methods, which may be used to accomplish this task, are discussed from the viewpoint of experimental fluid dynamicists. The Direct Linear Transformation (DLT) for camera calibration, used in pressure sensitive paint, is summarized. An optimization method for camera calibration is developed that can be used to determine the camera calibration parameters, including those describing lens distortion, from a single image. Combined with the DLT method, this method allows a rapid and comprehensive in-situ camera calibration and therefore is particularly useful for quantitative flow visualization and other measurements such as model attitude and deformation in production wind tunnels. The paper also includes a brief description of typical photogrammetric applications to temperature- and pressure-sensitive paint measurements and model deformation measurements in wind tunnels.

  1. An Overview of Conventional and Emerging Analytical Methods for the Determination of Mycotoxins

    PubMed Central

    Cigić, Irena Kralj; Prosen, Helena

    2009-01-01

    Mycotoxins are a group of compounds produced by various fungi and excreted into the matrices on which they grow, often food intended for human consumption or animal feed. The high toxicity and carcinogenicity of these compounds and their ability to cause various pathological conditions has led to widespread screening of foods and feeds potentially polluted with them. Maximum permissible levels in different matrices have also been established for some toxins. As these are quite low, analytical methods for determination of mycotoxins have to be both sensitive and specific. In addition, an appropriate sample preparation and pre-concentration method is needed to isolate analytes from rather complicated samples. In this article, an overview of methods for analysis and sample preparation published in the last ten years is given for the most often encountered mycotoxins in different samples, mainly in food. Special emphasis is on liquid chromatography with fluorescence and mass spectrometric detection, while in the field of sample preparation various solid-phase extraction approaches are discussed. However, an overview of other analytical and sample preparation methods less often used is also given. Finally, different matrices where mycotoxins have to be determined are discussed with the emphasis on their specific characteristics important for the analysis (human food and beverages, animal feed, biological samples, environmental samples). Various issues important for accurate qualitative and quantitative analyses are critically discussed: sampling and choice of representative sample, sample preparation and possible bias associated with it, specificity of the analytical method and critical evaluation of results. PMID:19333436

  2. Sensitive method for the quantitative determination of bromocriptine in human plasma by liquid chromatography-tandem mass spectrometry.

    PubMed

    Salvador, Arnaud; Dubreuil, Didier; Denouel, Jannick; Millerioux, L

    2005-06-25

    A sensitive LC-MS-MS assay for the quantitative determination of bromocriptine has been developed and validated and is described in this work. The assay involved the extraction of the analyte from 1 ml of human plasma using a solid phase extraction on Oasis MCX cartridges. Chromatography was performed on a Symmetry C18 (2.1 mm x 100 mm, 3.5 microm) column using a mobile phase consisting of 25:75:01 acetonitrile-water-formic acid with a flow rate of 250 microl/min. The linearity was within the concentration range of 2-500 pg/ml. The lower limit of quantification was 2 pg/ml. This method has been demonstrated to be an improvement over existing methods due to its greater sensitivity and specificity.

  3. A facile one-step fluorescence method for the quantitation of low-content single base deamination impurity in synthetic oligonucleotides.

    PubMed

    Su, Xiaoye; Liang, Ruiting; Stolee, Jessica A

    2018-06-05

    Oligonucleotides are being researched and developed as potential drug candidates for the treatment of a broad spectrum of diseases. The characterization of antisense oligonucleotide (ASO) impurities caused by base mutations (e.g. deamination) which are closely related to the target ASO is a significant analytical challenge. Herein, we describe a novel one-step method, utilizing a strategy that combines fluorescence-ON detection with competitive hybridization, to achieve single base mutation quantitation in extensively modified synthetic ASOs. Given that this method is highly specific and sensitive (LoQ = 4 nM), we envision that it will find utility for screening other impurities as well as sequencing modified oligonucleotides. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Diffuse Reflectance Infrared Fourier Transform Spectroscopy for the Determination of Asbestos Species in Bulk Building Materials

    PubMed Central

    Accardo, Grazia; Cioffi, Raffaeke; Colangelo, Francesco; d’Angelo, Raffaele; De Stefano, Luca; Paglietti, Fderica

    2014-01-01

    Diffuse reflectance infrared Fourier transform (DRIFT) spectroscopy is a well-known technique for thin film characterization. Since all asbestos species exhibit intense adsorptions peaks in the 4000–400 cm−1 region of the infrared spectrum, a quantitative analysis of asbestos in bulk samples by DRIFT is possible. In this work, different quantitative analytical procedures have been used to quantify chrysotile content in bulk materials produced by building requalification: partial least squares (PLS) chemometrics, the Linear Calibration Curve Method (LCM) and the Method of Additions (MoA). Each method has its own pros and cons, but all give affordable results for material characterization: the amount of asbestos (around 10%, weight by weight) can be determined with precision and accuracy (errors less than 0.1). PMID:28788467

  5. Quantitative Analysis of Nail Polish Remover Using Nuclear Magnetic Resonance Spectroscopy Revisited

    ERIC Educational Resources Information Center

    Hoffmann, Markus M.; Caccamis, Joshua T.; Heitz, Mark P.; Schlecht, Kenneth D.

    2008-01-01

    Substantial modifications are presented for a previously described experiment using nuclear magnetic resonance (NMR) spectroscopy to quantitatively determine analytes in commercial nail polish remover. The revised experiment is intended for a second- or third-year laboratory course in analytical chemistry and can be conducted for larger laboratory…

  6. Quantitative determination of carcinogenic mycotoxins in human and animal biological matrices and animal-derived foods using multi-mycotoxin and analyte-specific high performance liquid chromatography-tandem mass spectrometric methods.

    PubMed

    Cao, Xiaoqin; Li, Xiaofei; Li, Jian; Niu, Yunhui; Shi, Lu; Fang, Zhenfeng; Zhang, Tao; Ding, Hong

    2018-01-15

    A sensitive and reliable multi-mycotoxin-based method was developed to identify and quantify several carcinogenic mycotoxins in human blood and urine, as well as edible animal tissues, including muscle and liver tissue from swine and chickens, using liquid chromatography-tandem mass spectrometry (LC-MS/MS). For the toxicokinetic studies with individual mycotoxins, highly sensitive analyte-specific LC-MS/MS methods were developed for rat plasma and urine. Sample purification consisted of a rapid 'dilute and shoot' approach in urine samples, a simple 'dilute, evaporate and shoot' approach in plasma samples and a 'QuEChERS' procedure in edible animal tissues. The multi-mycotoxin and analyte-specific methods were validated in-house: The limits of detection (LOD) for the multi-mycotoxin and analyte-specific methods ranged from 0.02 to 0.41 μg/kg (μg/L) and 0.01 to 0.19 μg/L, respectively, and limits of quantification (LOQ) between 0.10 to 1.02 μg/kg (μg/L) and 0.09 to 0.47 μg/L, respectively. Apparent recoveries of the samples spiked with 0.25 to 4 μg/kg (μg/L) ranged from 60.1% to 109.8% with relative standard deviations below 15%. The methods were successfully applied to real samples. To the best of our knowledge, this is the first study carried out using a small group of patients from the Chinese population with hepatocellular carcinoma to assess their exposure to carcinogenic mycotoxins using biomarkers. Finally, the multi-mycotoxin method is a useful analytical method for assessing exposure to mycotoxins edible in animal tissues. The analyte-specific methods could be useful during toxicokinetic and toxicological studies. Copyright © 2017. Published by Elsevier B.V.

  7. Quantitation of permethylated N-glycans through multiple-reaction monitoring (MRM) LC-MS/MS.

    PubMed

    Zhou, Shiyue; Hu, Yunli; DeSantos-Garcia, Janie L; Mechref, Yehia

    2015-04-01

    The important biological roles of glycans and their implications in disease development and progression have created a demand for the development of sensitive quantitative glycomics methods. Quantitation of glycans existing at low abundance is still analytically challenging. In this study, an N-linked glycans quantitation method using multiple-reaction monitoring (MRM) on a triple quadrupole instrument was developed. Optimum normalized collision energy (CE) for both sialylated and fucosylated N-glycan was determined to be 30%, whereas it was found to be 35% for either fucosylated or sialylated N-glycans. The optimum CE for mannose and complex type N-glycan was determined to be 35%. Additionally, the use of three transitions was shown to facilitate reliable quantitation. A total of 88 N-glycan compositions in human blood serum were quantified using this MRM approach. Reliable detection and quantitation of these glycans was achieved when the equivalence of 0.005 μL of blood serum was analyzed. Accordingly, N-glycans down to the 100th of a μL level can be reliably quantified in pooled human blood serum, spanning a dynamic concentration range of three orders of magnitude. MRM was also effectively utilized to quantitatively compare the expression of N-glycans derived from brain-targeting breast carcinoma cells (MDA-MB-231BR) and metastatic breast cancer cells (MDA-MB-231). Thus, the described MRM method of permethylated N-glycan enables a rapid and reliable identification and quantitation of glycans derived from glycoproteins purified or present in complex biological samples.

  8. Quantitation of Permethylated N-Glycans through Multiple-Reaction Monitoring (MRM) LC-MS/MS

    NASA Astrophysics Data System (ADS)

    Zhou, Shiyue; Hu, Yunli; DeSantos-Garcia, Janie L.; Mechref, Yehia

    2015-04-01

    The important biological roles of glycans and their implications in disease development and progression have created a demand for the development of sensitive quantitative glycomics methods. Quantitation of glycans existing at low abundance is still analytically challenging. In this study, an N-linked glycans quantitation method using multiple-reaction monitoring (MRM) on a triple quadrupole instrument was developed. Optimum normalized collision energy (CE) for both sialylated and fucosylated N-glycan was determined to be 30%, whereas it was found to be 35% for either fucosylated or sialylated N-glycans. The optimum CE for mannose and complex type N-glycan was determined to be 35%. Additionally, the use of three transitions was shown to facilitate reliable quantitation. A total of 88 N-glycan compositions in human blood serum were quantified using this MRM approach. Reliable detection and quantitation of these glycans was achieved when the equivalence of 0.005 μL of blood serum was analyzed. Accordingly, N-glycans down to the 100th of a μL level can be reliably quantified in pooled human blood serum, spanning a dynamic concentration range of three orders of magnitude. MRM was also effectively utilized to quantitatively compare the expression of N-glycans derived from brain-targeting breast carcinoma cells (MDA-MB-231BR) and metastatic breast cancer cells (MDA-MB-231). Thus, the described MRM method of permethylated N-glycan enables a rapid and reliable identification and quantitation of glycans derived from glycoproteins purified or present in complex biological samples.

  9. GC-FID coupled with chemometrics for quantitative and chemical fingerprinting analysis of Alpinia oxyphylla oil.

    PubMed

    Miao, Qing; Kong, Weijun; Zhao, Xiangsheng; Yang, Shihai; Yang, Meihua

    2015-01-01

    Analytical methods for quantitative analysis and chemical fingerprinting of volatile oils from Alpinia oxyphylla were established. The volatile oils were prepared by hydrodistillation, and the yields were between 0.82% and 1.33%. The developed gas chromatography-flame ionization detection (GC-FID) method showed good specificity, linearity, reproducibility, stability and recovery, and could be used satisfactorily for quantitative analysis. The results showed that the volatile oils contained 2.31-77.30 μL/mL p-cymene and 12.38-99.34 mg/mL nootkatone. A GC-FID fingerprinting method was established, and the profiles were analyzed using chemometrics. GC-MS was used to identify the principal compounds in the GC-FID profiles. The profiles of almost all the samples were consistent and stable. The harvesting time and source were major factors that affected the profile, while the volatile oil yield and the nootkatone content had minor secondary effects. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Quantitative evaluation method of the threshold adjustment and the flat field correction performances of hybrid photon counting pixel detectors

    NASA Astrophysics Data System (ADS)

    Medjoubi, K.; Dawiec, A.

    2017-12-01

    A simple method is proposed in this work for quantitative evaluation of the quality of the threshold adjustment and the flat-field correction of Hybrid Photon Counting pixel (HPC) detectors. This approach is based on the Photon Transfer Curve (PTC) corresponding to the measurement of the standard deviation of the signal in flat field images. Fixed pattern noise (FPN), easily identifiable in the curve, is linked to the residual threshold dispersion, sensor inhomogeneity and the remnant errors in flat fielding techniques. The analytical expression of the signal to noise ratio curve is developed for HPC and successfully used as a fit function applied to experimental data obtained with the XPAD detector. The quantitative evaluation of the FPN, described by the photon response non-uniformity (PRNU), is measured for different configurations (threshold adjustment method and flat fielding technique) and is demonstrated to be used in order to evaluate the best setting for having the best image quality from a commercial or a R&D detector.

  11. Development and Evaluation of Event-Specific Quantitative PCR Method for Genetically Modified Soybean MON87701.

    PubMed

    Tsukahara, Keita; Takabatake, Reona; Masubuchi, Tomoko; Futo, Satoshi; Minegishi, Yasutaka; Noguchi, Akio; Kondo, Kazunari; Nishimaki-Mogami, Tomoko; Kurashima, Takeyo; Mano, Junichi; Kitta, Kazumi

    2016-01-01

    A real-time PCR-based analytical method was developed for the event-specific quantification of a genetically modified (GM) soybean event, MON87701. First, a standard plasmid for MON87701 quantification was constructed. The conversion factor (C f ) required to calculate the amount of genetically modified organism (GMO) was experimentally determined for a real-time PCR instrument. The determined C f for the real-time PCR instrument was 1.24. For the evaluation of the developed method, a blind test was carried out in an inter-laboratory trial. The trueness and precision were evaluated as the bias and reproducibility of relative standard deviation (RSDr), respectively. The determined biases and the RSDr values were less than 30 and 13%, respectively, at all evaluated concentrations. The limit of quantitation of the method was 0.5%, and the developed method would thus be applicable for practical analyses for the detection and quantification of MON87701.

  12. Ultrafast gas chromatography method with direct injection for the quantitative determination of benzene, toluene, ethylbenzene, and xylenes in commercial gasoline.

    PubMed

    Miranda, Nahieh Toscano; Sequinel, Rodrigo; Hatanaka, Rafael Rodrigues; de Oliveira, José Eduardo; Flumignan, Danilo Luiz

    2017-04-01

    Benzene, toluene, ethylbenzene, and xylenes are some of the most hazardous constituents found in commercial gasoline samples; therefore, these components must be monitored to avoid toxicological problems. We propose a new routine method of ultrafast gas chromatography coupled to flame ionization detection for the direct determination of benzene, toluene, ethylbenzene, and xylenes in commercial gasoline. This method is based on external standard calibration to quantify each compound, including the validation step of the study of linearity, detection and quantification limits, precision, and accuracy. The time of analysis was less than 3.2 min, with quantitative statements regarding the separation and quantification of all compounds in commercial gasoline samples. Ultrafast gas chromatography is a promising alternative method to official analytical techniques. Government laboratories could consider using this method for quality control. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Rapid determination of free fatty acid content in waste deodorizer distillates using single bounce-attenuated total reflectance-FTIR spectroscopy.

    PubMed

    Naz, Saba; Sherazi, Sayed Tufail Hussain; Talpur, Farah N; Mahesar, Sarfaraz A; Kara, Huseyin

    2012-01-01

    A simple, rapid, economical, and environmentally friendly analytical method was developed for the quantitative assessment of free fatty acids (FFAs) present in deodorizer distillates and crude oils by single bounce-attenuated total reflectance-FTIR spectroscopy. Partial least squares was applied for the calibration model based on the peak region of the carbonyl group (C=O) from 1726 to 1664 cm(-1) associated with the FFAs. The proposed method totally avoided the use of organic solvents or costly standards and could be applied easily in the oil processing industry. The accuracy of the method was checked by comparison to a conventional standard American Oil Chemists' Society (AOCS) titrimetric procedure, which provided good correlation (R = 0.99980), with an SD of +/- 0.05%. Therefore, the proposed method could be used as an alternate to the AOCS titrimetric method for the quantitative determination of FFAs especially in deodorizer distillates.

  14. Comparison of methods for determination of total oil sands-derived naphthenic acids in water samples.

    PubMed

    Hughes, Sarah A; Huang, Rongfu; Mahaffey, Ashley; Chelme-Ayala, Pamela; Klamerth, Nikolaus; Meshref, Mohamed N A; Ibrahim, Mohamed D; Brown, Christine; Peru, Kerry M; Headley, John V; Gamal El-Din, Mohamed

    2017-11-01

    There are several established methods for the determination of naphthenic acids (NAs) in waters associated with oil sands mining operations. Due to their highly complex nature, measured concentration and composition of NAs vary depending on the method used. This study compared different common sample preparation techniques, analytical instrument methods, and analytical standards to measure NAs in groundwater and process water samples collected from an active oil sands operation. In general, the high- and ultrahigh-resolution methods, namely high performance liquid chromatography time-of-flight mass spectrometry (UPLC-TOF-MS) and Orbitrap mass spectrometry (Orbitrap-MS), were within an order of magnitude of the Fourier transform infrared spectroscopy (FTIR) methods. The gas chromatography mass spectrometry (GC-MS) methods consistently had the highest NA concentrations and greatest standard error. Total NAs concentration was not statistically different between sample preparation of solid phase extraction and liquid-liquid extraction. Calibration standards influenced quantitation results. This work provided a comprehensive understanding of the inherent differences in the various techniques available to measure NAs and hence the potential differences in measured amounts of NAs in samples. Results from this study will contribute to the analytical method standardization for NA analysis in oil sands related water samples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. High-throughput label-free screening of euglena gracilis with optofluidic time-stretch quantitative phase microscopy

    NASA Astrophysics Data System (ADS)

    Guo, Baoshan; Lei, Cheng; Ito, Takuro; Yaxiaer, Yalikun; Kobayashi, Hirofumi; Jiang, Yiyue; Tanaka, Yo; Ozeki, Yasuyuki; Goda, Keisuke

    2017-02-01

    The development of reliable, sustainable, and economical sources of alternative fuels is an important, but challenging goal for the world. As an alternative to liquid fossil fuels, microalgal biofuel is expected to play a key role in reducing the detrimental effects of global warming since microalgae absorb atmospheric CO2 via photosynthesis. Unfortunately, conventional analytical methods only provide population-averaged lipid contents and fail to characterize a diverse population of microalgal cells with single-cell resolution in a noninvasive and interference-free manner. Here we demonstrate high-throughput label-free single-cell screening of lipid-producing microalgal cells with optofluidic time-stretch quantitative phase microscopy. In particular, we use Euglena gracilis - an attractive microalgal species that produces wax esters (suitable for biodiesel and aviation fuel after refinement) within lipid droplets. Our optofluidic time-stretch quantitative phase microscope is based on an integration of a hydrodynamic-focusing microfluidic chip, an optical time-stretch phase-contrast microscope, and a digital image processor equipped with machine learning. As a result, it provides both the opacity and phase contents of every single cell at a high throughput of 10,000 cells/s. We characterize heterogeneous populations of E. gracilis cells under two different culture conditions to evaluate their lipid production efficiency. Our method holds promise as an effective analytical tool for microalgaebased biofuel production.

  16. Quantitative Profiling of Endogenous Fat-Soluble Vitamins and Carotenoids in Human Plasma Using an Improved UHPSFC-ESI-MS Interface.

    PubMed

    Petruzziello, Filomena; Grand-Guillaume Perrenoud, Alexandre; Thorimbert, Anita; Fogwill, Michael; Rezzi, Serge

    2017-07-18

    Analytical solutions enabling the quantification of circulating levels of liposoluble micronutrients such as vitamins and carotenoids are currently limited to either single or a reduced panel of analytes. The requirement to use multiple approaches hampers the investigation of the biological variability on a large number of samples in a time and cost efficient manner. With the goal to develop high-throughput and robust quantitative methods for the profiling of micronutrients in human plasma, we introduce a novel, validated workflow for the determination of 14 fat-soluble vitamins and carotenoids in a single run. Automated supported liquid extraction was optimized and implemented to simultaneously parallelize 48 samples in 1 h, and the analytes were measured using ultrahigh-performance supercritical fluid chromatography coupled to tandem mass spectrometry in less than 8 min. An improved mass spectrometry interface hardware was built up to minimize the post-decompression volume and to allow better control of the chromatographic effluent density on its route toward and into the ion source. In addition, a specific make-up solvent condition was developed to ensure both analytes and matrix constituents solubility after mobile phase decompression. The optimized interface resulted in improved spray plume stability and conserved matrix compounds solubility leading to enhanced hyphenation robustness while ensuring both suitable analytical repeatability and improved the detection sensitivity. The overall developed methodology gives recoveries within 85-115%, as well as within and between-day coefficient of variation of 2 and 14%, respectively.

  17. Optimization and automation of quantitative NMR data extraction.

    PubMed

    Bernstein, Michael A; Sýkora, Stan; Peng, Chen; Barba, Agustín; Cobas, Carlos

    2013-06-18

    NMR is routinely used to quantitate chemical species. The necessary experimental procedures to acquire quantitative data are well-known, but relatively little attention has been applied to data processing and analysis. We describe here a robust expert system that can be used to automatically choose the best signals in a sample for overall concentration determination and determine analyte concentration using all accepted methods. The algorithm is based on the complete deconvolution of the spectrum which makes it tolerant of cases where signals are very close to one another and includes robust methods for the automatic classification of NMR resonances and molecule-to-spectrum multiplets assignments. With the functionality in place and optimized, it is then a relatively simple matter to apply the same workflow to data in a fully automatic way. The procedure is desirable for both its inherent performance and applicability to NMR data acquired for very large sample sets.

  18. Quantitative imaging of aggregated emulsions.

    PubMed

    Penfold, Robert; Watson, Andrew D; Mackie, Alan R; Hibberd, David J

    2006-02-28

    Noise reduction, restoration, and segmentation methods are developed for the quantitative structural analysis in three dimensions of aggregated oil-in-water emulsion systems imaged by fluorescence confocal laser scanning microscopy. Mindful of typical industrial formulations, the methods are demonstrated for concentrated (30% volume fraction) and polydisperse emulsions. Following a regularized deconvolution step using an analytic optical transfer function and appropriate binary thresholding, novel application of the Euclidean distance map provides effective discrimination of closely clustered emulsion droplets with size variation over at least 1 order of magnitude. The a priori assumption of spherical nonintersecting objects provides crucial information to combat the ill-posed inverse problem presented by locating individual particles. Position coordinates and size estimates are recovered with sufficient precision to permit quantitative study of static geometrical features. In particular, aggregate morphology is characterized by a novel void distribution measure based on the generalized Apollonius problem. This is also compared with conventional Voronoi/Delauney analysis.

  19. Proxy-to-proxy calibration: Increasing the temporal resolution of quantitative climate reconstructions

    PubMed Central

    von Gunten, Lucien; D'Andrea, William J.; Bradley, Raymond S.; Huang, Yongsong

    2012-01-01

    High-resolution paleoclimate reconstructions are often restricted by the difficulties of sampling geologic archives in great detail and the analytical costs of processing large numbers of samples. Using sediments from Lake Braya Sø, Greenland, we introduce a new method that provides a quantitative high-resolution paleoclimate record by combining measurements of the alkenone unsaturation index () with non-destructive scanning reflectance spectroscopic measurements in the visible range (VIS-RS). The proxy-to-proxy (PTP) method exploits two distinct calibrations: the in situ calibration of to lake water temperature and the calibration of scanning VIS-RS data to down core data. Using this approach, we produced a quantitative temperature record that is longer and has 5 times higher sampling resolution than the original time series, thereby allowing detection of temperature variability in frequency bands characteristic of the AMO over the past 7,000 years. PMID:22934132

  20. Quantification of N-acetyl- and N-glycolylneuraminic acids by a stable isotope dilution assay using high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Allevi, Pietro; Femia, Eti Alessandra; Costa, Maria Letizia; Cazzola, Roberta; Anastasia, Mario

    2008-11-28

    The present report describes a method for the quantification of N-acetyl- and N-glycolylneuraminic acids without any derivatization, using their (13)C(3)-isotopologues as internal standards and a C(18) reversed-phase column modified by decylboronic acid which allows for the first time a complete chromatographic separation between the two analytes. The method is based on high-performance liquid chromatographic coupled with electrospray ion-trap mass spectrometry. The limit of quantification of the method is 0.1mg/L (2.0ng on column) for both analytes. The calibration curves are linear for both sialic acids over the range of 0.1-80mg/L (2.0-1600ng on column) with a correlation coefficient greater than 0.997. The proposed method was applied to the quantitative determination of sialic acids released from fetuin as a model of glycoproteins.

  1. Method and platform standardization in MRM-based quantitative plasma proteomics.

    PubMed

    Percy, Andrew J; Chambers, Andrew G; Yang, Juncong; Jackson, Angela M; Domanski, Dominik; Burkhart, Julia; Sickmann, Albert; Borchers, Christoph H

    2013-12-16

    There exists a growing demand in the proteomics community to standardize experimental methods and liquid chromatography-mass spectrometry (LC/MS) platforms in order to enable the acquisition of more precise and accurate quantitative data. This necessity is heightened by the evolving trend of verifying and validating candidate disease biomarkers in complex biofluids, such as blood plasma, through targeted multiple reaction monitoring (MRM)-based approaches with stable isotope-labeled standards (SIS). Considering the lack of performance standards for quantitative plasma proteomics, we previously developed two reference kits to evaluate the MRM with SIS peptide approach using undepleted and non-enriched human plasma. The first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). Here, these kits have been refined for practical use and then evaluated through intra- and inter-laboratory testing on 6 common LC/MS platforms. For an identical panel of 22 plasma proteins, similar concentrations were determined, regardless of the kit, instrument platform, and laboratory of analysis. These results demonstrate the value of the kit and reinforce the utility of standardized methods and protocols. The proteomics community needs standardized experimental protocols and quality control methods in order to improve the reproducibility of MS-based quantitative data. This need is heightened by the evolving trend for MRM-based validation of proposed disease biomarkers in complex biofluids such as blood plasma. We have developed two kits to assist in the inter- and intra-laboratory quality control of MRM experiments: the first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). In this paper, we report the use of these kits in intra- and inter-laboratory testing on 6 common LC/MS platforms. This article is part of a Special Issue entitled: Standardization and Quality Control in Proteomics. © 2013.

  2. A fit-for-purpose LC-MS/MS method for the simultaneous quantitation of ATP and 2,3-DPG in human K2EDTA whole blood.

    PubMed

    Kim, Hyeryun; Kosinski, Penelope; Kung, Charles; Dang, Lenny; Chen, Yue; Yang, Hua; Chen, Yuan-Shek; Kramer, Jordyn; Liu, Guowen

    2017-09-01

    Many hemolytic anemias results in major metabolic abnormalities: two common metabolite abnormalities include increased levels of 2,3-diphosphoglycerate (2,3-DPG) and decreased levels of adenosine triphosphate (ATP). To better monitor the concentration changes of these metabolites, the development of a reliable LC-MS/MS method to quantitatively profile the concentrations of 2, 3-DPG and ATP in whole blood is essential to understand the effects of investigational therapeutics. Accurate quantification of both compounds imposes great challenges to bioanalytical scientists due to their polar, ionic and endogenous nature. Here we present an LC-MS/MS method for the reliable quantification of 2,3-DPG and ATP from K 2 EDTA human whole blood (WB) simultaneously. Whole blood samples were spiked with stable isotope labeled internal standards, processed by protein precipitation extraction, and analyzed using zwitterionic ion chromatography-hydrophilic interaction chromatography (ZIC-HILIC) coupled with tandem mass spectrometry. The linear analytical range of the assay was 50-3000μg/mL. The fit-for-purpose method demonstrated excellent accuracy and precision. The overall accuracy was within ±10.5% (%RE) for both analytes and the intra- and inter-assay precision (%CV) were less than 6.7% and 6.2% for both analytes, respectively. ATP and 2,3-DPG were found to be stable in human K 2 EDTA blood for at least 8h at 4°C, 96days when stored at -70°C and after three freeze/thaw cycles. The assay has been successfully applied to K 2 EDTA human whole blood samples to support clinical studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. A Lean Six Sigma approach to the improvement of the selenium analysis method.

    PubMed

    Cloete, Bronwyn C; Bester, André

    2012-11-02

    Reliable results represent the pinnacle assessment of quality of an analytical laboratory, and therefore variability is considered to be a critical quality problem associated with the selenium analysis method executed at Western Cape Provincial Veterinary Laboratory (WCPVL). The elimination and control of variability is undoubtedly of significant importance because of the narrow margin of safety between toxic and deficient doses of the trace element for good animal health. A quality methodology known as Lean Six Sigma was believed to present the most feasible solution for overcoming the adverse effect of variation, through steps towards analytical process improvement. Lean Six Sigma represents a form of scientific method type, which is empirical, inductive and deductive, and systematic, which relies on data, and is fact-based. The Lean Six Sigma methodology comprises five macro-phases, namely Define, Measure, Analyse, Improve and Control (DMAIC). Both qualitative and quantitative laboratory data were collected in terms of these phases. Qualitative data were collected by using quality-tools, namely an Ishikawa diagram, a Pareto chart, Kaizen analysis and a Failure Mode Effect analysis tool. Quantitative laboratory data, based on the analytical chemistry test method, were collected through a controlled experiment. The controlled experiment entailed 13 replicated runs of the selenium test method, whereby 11 samples were repetitively analysed, whilst Certified Reference Material (CRM) was also included in 6 of the runs. Laboratory results obtained from the controlled experiment was analysed by using statistical methods, commonly associated with quality validation of chemistry procedures. Analysis of both sets of data yielded an improved selenium analysis method, believed to provide greater reliability of results, in addition to a greatly reduced cycle time and superior control features. Lean Six Sigma may therefore be regarded as a valuable tool in any laboratory, and represents both a management discipline, and a standardised approach to problem solving and process optimisation.

  4. Semi-quantitative methods yield greater inter- and intraobserver agreement than subjective methods for interpreting 99m technetium-hydroxymethylene-diphosphonate uptake in equine thoracic processi spinosi.

    PubMed

    van Zadelhoff, Claudia; Ehrle, Anna; Merle, Roswitha; Jahn, Werner; Lischer, Christoph

    2018-05-09

    Scintigraphy is a standard diagnostic method for evaluating horses with back pain due to suspected thoracic processus spinosus pathology. Lesion detection is based on subjective or semi-quantitative assessments of increased uptake. This retrospective, analytical study is aimed to compare semi-quantitative and subjective methods in the evaluation of scintigraphic images of the processi spinosi in the equine thoracic spine. Scintigraphic images of 20 Warmblood horses, presented for assessment of orthopedic conditions between 2014 and 2016, were included in the study. Randomized, blinded image evaluation was performed by 11 veterinarians using subjective and semi-quantitative methods. Subjective grading was performed for the analysis of red-green-blue and grayscale scintigraphic images, which were presented in full-size or as masked images. For the semi-quantitative assessment, observers placed regions of interest over each processus spinosus. The uptake ratio of each processus spinosus in comparison to a reference region of interest was determined. Subsequently, a modified semi-quantitative calculation was developed whereby only the highest counts-per-pixel for a specified number of pixels was processed. Inter- and intraobserver agreement was calculated using intraclass correlation coefficients. Inter- and intraobserver intraclass correlation coefficients were 41.65% and 71.39%, respectively, for the subjective image assessment. Additionally, a correlation between intraobserver agreement, experience, and grayscale images was identified. The inter- and intraobserver agreement was significantly increased when using semi-quantitative analysis (97.35% and 98.36%, respectively) or the modified semi-quantitative calculation (98.61% and 98.82%, respectively). The proposed modified semi-quantitative technique showed a higher inter- and intraobserver agreement when compared to other methods, which makes it a useful tool for the analysis of scintigraphic images. The association of the findings from this study with clinical and radiological examinations requires further investigation. © 2018 American College of Veterinary Radiology.

  5. Development and validation of the first liquid chromatography-tandem mass spectrometry assay for simultaneous quantification of multiple antiretrovirals in meconium.

    PubMed

    Himes, Sarah K; Scheidweiler, Karl B; Tassiopoulos, Katherine; Kacanek, Deborah; Hazra, Rohan; Rich, Kenneth; Huestis, Marilyn A

    2013-02-05

    A novel method for the simultaneous quantification of 16 antiretroviral (ARV) drugs and 4 metabolites in meconium was developed and validated. Quantification of 6 nucleoside/nucleotide reverse transcriptase inhibitors, 2 non-nucleoside reverse transcriptase inhibitors, 7 protease inhibitors, and 1 integrase inhibitor was achieved in 0.25 g of meconium. Specimen preparation included methanol homogenization and solid-phase extraction. Separate positive and negative polarity multiple reaction monitoring mode injections were required to achieve sufficient sensitivity. Linearity ranged from 10 to 75 ng/g up to 2500 ng/g for most analytes and 100-500 ng/g up to 25,000 ng/g for some; all correlation coefficients were ≥0.99. Extraction efficiencies from meconium were 32.8-119.5% with analytical recovery of 80.3-108.3% and total imprecision of 2.2-11.0% for all quantitative analytes. Two analytes with analytical recovery (70.0-138.5%) falling outside the 80-120% criteria range were considered semiquantitative. Matrix effects were -98.3-47.0% and -98.0-67.2% for analytes and internal standards, respectively. Analytes were stable (>75%) at room temperature for 24 h, 4 °C for 3 days, -20 °C for 3 freeze-thaw cycles over 3 days, and on the autosampler. Method applicability was demonstrated by analyzing meconium from HIV-uninfected infants born to HIV-positive mothers on ARV therapy. This method can be used as a tool to investigate the potential effects of in utero ARV exposure on childhood health and neurodevelopmental outcomes.

  6. A simultaneous screening and quantitative method for the multiresidue analysis of pesticides in spices using ultra-high performance liquid chromatography-high resolution (Orbitrap) mass spectrometry.

    PubMed

    Goon, Arnab; Khan, Zareen; Oulkar, Dasharath; Shinde, Raviraj; Gaikwad, Suresh; Banerjee, Kaushik

    2018-01-12

    A novel screening and quantitation method is reported for non-target multiresidue analysis of pesticides using ultra-HPLC-quadrupole-Orbitrap mass spectrometry in spice matrices, including black pepper, cardamom, chili, coriander, cumin, and turmeric. The method involved sequential full-scan (resolution = 70,000), and variable data independent acquisition (vDIA) with nine consecutive fragmentation events (resolution = 17,500). Samples were extracted by the QuEChERS method. The introduction of an SPE-based clean-up step through hydrophilic-lipophilic-balance (HLB) cartridges proved advantageous in minimizing the false negatives. For coriander, cumin, chili, and cardamom, the screening detection limit was largely at 2 ng/g, while it was 5 ng/g for black pepper, and turmeric. When the method was quantitatively validated for 199 pesticides, the limit of quantification (LOQ) was mostly at 10 ng/g (excluding black pepper, and turmeric with LOQ = 20 ng/g) with recoveries within 70-120%, and precision-RSDs <20%. Furthermore, the method allowed the identification of suspected non-target analytes through retrospective search of the accurate mass of the compound-specific precursor and product ions. Compared to LC-MS/MS, the quantitative performance of this Orbitrap-MS method had agreements in residue values between 78-100%. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Computer modeling of lung cancer diagnosis-to-treatment process

    PubMed Central

    Ju, Feng; Lee, Hyo Kyung; Osarogiagbon, Raymond U.; Yu, Xinhua; Faris, Nick

    2015-01-01

    We introduce an example of a rigorous, quantitative method for quality improvement in lung cancer care-delivery. Computer process modeling methods are introduced for lung cancer diagnosis, staging and treatment selection process. Two types of process modeling techniques, discrete event simulation (DES) and analytical models, are briefly reviewed. Recent developments in DES are outlined and the necessary data and procedures to develop a DES model for lung cancer diagnosis, leading up to surgical treatment process are summarized. The analytical models include both Markov chain model and closed formulas. The Markov chain models with its application in healthcare are introduced and the approach to derive a lung cancer diagnosis process model is presented. Similarly, the procedure to derive closed formulas evaluating the diagnosis process performance is outlined. Finally, the pros and cons of these methods are discussed. PMID:26380181

  8. Graphite nanocomposites sensor for multiplex detection of antioxidants in food.

    PubMed

    Ng, Khan Loon; Tan, Guan Huat; Khor, Sook Mei

    2017-12-15

    Butylated hydroxyanisole (BHA), butylated hydroxytoluene (BHT), and tert-butylhydroquinone (TBHQ) are synthetic antioxidants used in the food industry. Herein, we describe the development of a novel graphite nanocomposite-based electrochemical sensor for the multiplex detection and measurement of BHA, BHT, and TBHQ levels in complex food samples using a linear sweep voltammetry technique. Moreover, our newly established analytical method exhibited good sensitivity, limit of detection, limit of quantitation, and selectivity. The accuracy and reliability of analytical results were challenged by method validation and comparison with the results of the liquid chromatography method, where a linear correlation of more than 0.99 was achieved. The addition of sodium dodecyl sulfate as supporting additive further enhanced the LSV response (anodic peak current, I pa ) of BHA and BHT by 2- and 20-times, respectively. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Multi-residue analysis of pesticides, plant hormones, veterinary drugs and mycotoxins using HILIC chromatography - MS/MS in various food matrices.

    PubMed

    Danezis, G P; Anagnostopoulos, C J; Liapis, K; Koupparis, M A

    2016-10-26

    One of the recent trends in Analytical Chemistry is the development of economic, quick and easy hyphenated methods to be used in a field that includes analytes of different classes and physicochemical properties. In this work a multi-residue method was developed for the simultaneous determination of 28 xenobiotics (polar and hydrophilic) using hydrophilic interaction liquid chromatography technique (HILIC) coupled with triple quadrupole mass spectrometry (LC-MS/MS) technology. The scope of the method includes plant growth regulators (chlormequat, daminozide, diquat, maleic hydrazide, mepiquat, paraquat), pesticides (cyromazine, the metabolite of the fungicide propineb PTU (propylenethiourea), amitrole), various multiclass antibiotics (tetracyclines, sulfonamides quinolones, kasugamycin and mycotoxins (aflatoxin B1, B2, fumonisin B1 and ochratoxin A). Isolation of the analytes from the matrix was achieved with a fast and effective technique. The validation of the multi-residue method was performed at the levels: 10 μg/kg and 100 μg/kg in the following representative substrates: fruits-vegetables (apples, apricots, lettuce and onions), cereals and pulses (flour and chickpeas), animal products (milk and meat) and cereal based baby foods. The method was validated taking into consideration EU guidelines and showed acceptable linearity (r ≥ 0.99), accuracy with recoveries between 70 and 120% and precision with RSD ≤ 20% for the majority of the analytes studied. For the analytes that presented accuracy and precision values outside the acceptable limits the method still is able to serve as a semi-quantitative method. The matrix effect, the limits of detection and quantification were also estimated and compared with the current EU MRLs (Maximum Residue Levels) and FAO/WHO MLs (Maximum Levels) or CXLs (Codex Maximum Residue Limits). The combined and expanded uncertainty of the method for each analyte per substrate, was also estimated. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. A systematic study on the influencing parameters and improvement of quantitative analysis of multi-component with single marker method using notoginseng as research subject.

    PubMed

    Wang, Chao-Qun; Jia, Xiu-Hong; Zhu, Shu; Komatsu, Katsuko; Wang, Xuan; Cai, Shao-Qing

    2015-03-01

    A new quantitative analysis of multi-component with single marker (QAMS) method for 11 saponins (ginsenosides Rg1, Rb1, Rg2, Rh1, Rf, Re and Rd; notoginsenosides R1, R4, Fa and K) in notoginseng was established, when 6 of these saponins were individually used as internal referring substances to investigate the influences of chemical structure, concentrations of quantitative components, and purities of the standard substances on the accuracy of the QAMS method. The results showed that the concentration of the analyte in sample solution was the major influencing parameter, whereas the other parameters had minimal influence on the accuracy of the QAMS method. A new method for calculating the relative correction factors by linear regression was established (linear regression method), which demonstrated to decrease standard method differences of the QAMS method from 1.20%±0.02% - 23.29%±3.23% to 0.10%±0.09% - 8.84%±2.85% in comparison with the previous method. And the differences between external standard method and the QAMS method using relative correction factors calculated by linear regression method were below 5% in the quantitative determination of Rg1, Re, R1, Rd and Fa in 24 notoginseng samples and Rb1 in 21 notoginseng samples. And the differences were mostly below 10% in the quantitative determination of Rf, Rg2, R4 and N-K (the differences of these 4 constituents bigger because their contents lower) in all the 24 notoginseng samples. The results indicated that the contents assayed by the new QAMS method could be considered as accurate as those assayed by external standard method. In addition, a method for determining applicable concentration ranges of the quantitative components assayed by QAMS method was established for the first time, which could ensure its high accuracy and could be applied to QAMS methods of other TCMs. The present study demonstrated the practicability of the application of the QAMS method for the quantitative analysis of multi-component and the quality control of TCMs and TCM prescriptions. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. A rapid miniaturized residue analytical method for the determination of zoxamide and its two acid metabolites in ginseng roots using UPLC-MS/MS.

    PubMed

    Podhorniak, Lynda V

    2014-04-30

    A miniaturized residue method was developed for the analysis of the fungicide zoxamide and its metabolites in dried ginseng root. The zoxamide metabolites, 3,5-dichloro-1,4-benzenedicarboxylic acid (DCBC) and 3,5-dichloro-4-hydroxymethylbenzoic acid (DCHB), are small acid molecules that have not been previously extracted from the ginseng matrix with common multiresidue methods. The presented extraction method effectively and rapidly recovers both the zoxamide parent compound and its acid metabolites from fortified ginseng root. The metabolites are extracted with an alkaline glycine buffer and the aqueous ginseng mixture is partitioned with ethyl acetate. In addition, this method avoids the use of derivatization of the small acid molecules by using UPLC-MS/MS instrumental analysis. In a quantitative validation of the analytical method at three levels for zoxamide (0.007 (LOD), 0.02 (LOQ), and 0.2 mg/kg) and four levels (0.07 (LOD), 0.2 (LOQ), and 0.6 and 6 mg/kg) for both metabolites, acceptable method performances were achieved with recoveries ranging from 86 to 107% (at levels of LOQ and 3×, 10×, and 30× the LOQ) with <20% RSD for the three analytes in accordance with international guidelines.1.

  12. Development of quantitative screen for 1550 chemicals with GC-MS.

    PubMed

    Bergmann, Alan J; Points, Gary L; Scott, Richard P; Wilson, Glenn; Anderson, Kim A

    2018-05-01

    With hundreds of thousands of chemicals in the environment, effective monitoring requires high-throughput analytical techniques. This paper presents a quantitative screening method for 1550 chemicals based on statistical modeling of responses with identification and integration performed using deconvolution reporting software. The method was evaluated with representative environmental samples. We tested biological extracts, low-density polyethylene, and silicone passive sampling devices spiked with known concentrations of 196 representative chemicals. A multiple linear regression (R 2  = 0.80) was developed with molecular weight, logP, polar surface area, and fractional ion abundance to predict chemical responses within a factor of 2.5. Linearity beyond the calibration had R 2  > 0.97 for three orders of magnitude. Median limits of quantitation were estimated to be 201 pg/μL (1.9× standard deviation). The number of detected chemicals and the accuracy of quantitation were similar for environmental samples and standard solutions. To our knowledge, this is the most precise method for the largest number of semi-volatile organic chemicals lacking authentic standards. Accessible instrumentation and software make this method cost effective in quantifying a large, customizable list of chemicals. When paired with silicone wristband passive samplers, this quantitative screen will be very useful for epidemiology where binning of concentrations is common. Graphical abstract A multiple linear regression of chemical responses measured with GC-MS allowed quantitation of 1550 chemicals in samples such as silicone wristbands.

  13. Effect of different analyte diffusion/adsorption protocols on SERS signals

    NASA Astrophysics Data System (ADS)

    Li, Ruoping; Petschek, Rolfe G.; Han, Junhe; Huang, Mingju

    2018-07-01

    The effect of different analyte diffusion/adsorption protocols was studied which is often overlooked in surface-enhanced Raman scattering (SERS) technique. Three protocols: highly concentrated dilution (HCD) protocol, half-half dilution (HHD) protocol and layered adsorption (LA) protocol were studied and the SERS substrates were monolayer films of 80 nm Ag nanoparticles (NPs) which were modified by polyvinylpyrrolidone. The diffusion/adsorption mechanisms were modelled using the diffusion equation and the electromagnetic field distribution of two adjacent Ag NPs was simulated by the finite-different time-domain method. All experimental data and theoretical analysis suggest that different diffusion/adsorption behaviour of analytes will cause different SERS signal enhancements. HHD protocol could produce the most uniform and reproducible samples, and the corresponding signal intensity of the analyte is the strongest. This study will help to understand and promote the use of SERS technique in quantitative analysis.

  14. Cross-stream diffusion under pressure-driven flow in microchannels with arbitrary aspect ratios: a phase diagram study using a three-dimensional analytical model

    PubMed Central

    Song, Hongjun; Wang, Yi; Pant, Kapil

    2011-01-01

    This article presents a three-dimensional analytical model to investigate cross-stream diffusion transport in rectangular microchannels with arbitrary aspect ratios under pressure-driven flow. The Fourier series solution to the three-dimensional convection–diffusion equation is obtained using a double integral transformation method and associated eigensystem calculation. A phase diagram derived from the dimensional analysis is presented to thoroughly interrogate the characteristics in various transport regimes and examine the validity of the model. The analytical model is verified against both experimental and numerical models in terms of the concentration profile, diffusion scaling law, and mixing efficiency with excellent agreement (with <0.5% relative error). Quantitative comparison against other prior analytical models in extensive parameter space is also performed, which demonstrates that the present model accommodates much broader transport regimes with significantly enhanced applicability. PMID:22247719

  15. Cross-stream diffusion under pressure-driven flow in microchannels with arbitrary aspect ratios: a phase diagram study using a three-dimensional analytical model.

    PubMed

    Song, Hongjun; Wang, Yi; Pant, Kapil

    2012-01-01

    This article presents a three-dimensional analytical model to investigate cross-stream diffusion transport in rectangular microchannels with arbitrary aspect ratios under pressure-driven flow. The Fourier series solution to the three-dimensional convection-diffusion equation is obtained using a double integral transformation method and associated eigensystem calculation. A phase diagram derived from the dimensional analysis is presented to thoroughly interrogate the characteristics in various transport regimes and examine the validity of the model. The analytical model is verified against both experimental and numerical models in terms of the concentration profile, diffusion scaling law, and mixing efficiency with excellent agreement (with <0.5% relative error). Quantitative comparison against other prior analytical models in extensive parameter space is also performed, which demonstrates that the present model accommodates much broader transport regimes with significantly enhanced applicability.

  16. Quantitation of aflatoxins from corn and other food related materials by direct analysis in real time - mass spectrometry (DART-MS)

    USDA-ARS?s Scientific Manuscript database

    Ambient ionization coupled to mass spectrometry continues to be applied to new analytical problems, facilitating the rapid and convenient analysis of a variety of analytes. Recently, demonstrations of ambient ionization mass spectrometry applied to quantitative analysis of mycotoxins have been shown...

  17. Application of enhanced gas chromatography/triple quadrupole mass spectrometry for monitoring petroleum weathering and forensic source fingerprinting in samples impacted by the Deepwater Horizon oil spill.

    PubMed

    Adhikari, Puspa L; Wong, Roberto L; Overton, Edward B

    2017-10-01

    Accurate characterization of petroleum hydrocarbons in complex and weathered oil residues is analytically challenging. This is primarily due to chemical compositional complexity of both the oil residues and environmental matrices, and the lack of instrumental selectivity due to co-elution of interferences with the target analytes. To overcome these analytical selectivity issues, we used an enhanced resolution gas chromatography coupled with triple quadrupole mass spectrometry in Multiple Reaction Monitoring (MRM) mode (GC/MS/MS-MRM) to eliminate interferences within the ion chromatograms of target analytes found in environmental samples. This new GC/MS/MS-MRM method was developed and used for forensic fingerprinting of deep-water and marsh sediment samples containing oily residues from the Deepwater Horizon oil spill. The results showed that the GC/MS/MS-MRM method increases selectivity, eliminates interferences, and provides more accurate quantitation and characterization of trace levels of alkyl-PAHs and biomarker compounds, from weathered oil residues in complex sample matrices. The higher selectivity of the new method, even at low detection limits, provides greater insights on isomer and homolog compositional patterns and the extent of oil weathering under various environmental conditions. The method also provides flat chromatographic baselines for accurate and unambiguous calculation of petroleum forensic biomarker compound ratios. Thus, this GC/MS/MS-MRM method can be a reliable analytical strategy for more accurate and selective trace level analyses in petroleum forensic studies, and for tacking continuous weathering of oil residues. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Development and validation of a highly sensitive gas chromatographic-mass spectrometric screening method for the simultaneous determination of nanogram levels of fentanyl, sufentanil and alfentanil in air and surface contamination wipes.

    PubMed

    Van Nimmen, Nadine F J; Veulemans, Hendrik A F

    2004-05-07

    A highly sensitive gas chromatographic-mass spectrometric (GC-MS) analytical method for the determination of the opioid narcotics fentanyl, alfentanil, and sufentanil in industrial hygiene personal air samples and surface contamination wipes was developed and comprehensively validated. Sample preparation involved a single step extraction of the samples with methanol, fortified with a fixed amount of the penta-deuterated analogues of the opioid narcotics as internal standard. The GC-MS analytical procedure using selected ion monitoring (SIM) was shown to be highly selective. Linearity was shown for levels of extracted wipe and air samples corresponding to at least 0.1-2 times their surface contamination limit (SCL) and accordingly to 0.1-2 times their time weighted average occupational exposure limit (OEL-TWA) based on a full shift 9601 air sample. Extraction recoveries were determined for spiked air samples and surface wipes and were found to be quantitative for both sampling media in the entire range studied. The air sampling method's limit of detection (LOD) was determined to be 0.4 ng per sample for fentanyl and sufentanil and 1.6 ng per sample for alfentanil, corresponding to less than 1% of their individual OEL for a full shift air sample (9601). The limit of quantification (LOQ) was found to be 1.4, 1.2, and 5.0 ng per filter for fentanyl, sufentanil, and alfentanil, respectively. The wipe sampling method had LODs of 4 ng per wipe for fentanyl and sufentanil and 16 ng per wipe for alfentanil and LOQs of respectively, 14, 12, and 50 ng per wipe. The analytical intra-assay precision of the air sampling and wipe sampling method, defined as the coefficient of variation on the analytical result of six replicate spiked media was below 10 and 5%, respectively, for all opioids at all spike levels. Accuracy expressed as relative error was determined to be below 10%, except for alfentanil at the lowest spike level (-13.1%). The stability of the opioids during simulated air sampling was investigated. For fentanyl and sufentanil a quantitative recovery was observed at all spike levels, while for alfentanil recoveries ranged from 60.3 to 85.4%. When spiked air samples were stored at ambient temperature and at -15 degrees C quantitative recovery was found for fentanyl and sufentanil after 7 and 14 days. For alfentanil a slight loss seemed to occur upon storage during 7 days, being more explicit after 14 days. Ambient storage of spiked wipes seemed to lead to significant losses of all opioids studied, yielding recoveries of 37.7-88.3%. Upon storage of similar wipes at -15 degrees C a significantly higher recovery was found ranging from 77.3 to 88.3%. The developed analytical and sampling procedures have been recently applied in an explorative field study of which the results of surface contamination wipe sampling are presented in this paper. To our knowledge, this is the first study addressing the development and validation of analytical procedures for the assessment of external occupational exposure to potent opioid narcotics.

  19. High temperature polymer degradation: Rapid IR flow-through method for volatile quantification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giron, Nicholas H.; Celina, Mathew C.

    Accelerated aging of polymers at elevated temperatures often involves the generation of volatiles. These can be formed as the products of oxidative degradation reactions or intrinsic pyrolytic decomposition as part of polymer scission reactions. A simple analytical method for the quantification of water, CO 2, and CO as fundamental signatures of degradation kinetics is required. Here, we describe an analytical framework and develops a rapid mid-IR based gas analysis methodology to quantify volatiles that are contained in small ampoules after aging exposures. The approach requires identification of unique spectral signatures, systematic calibration with known concentrations of volatiles, and a rapidmore » acquisition FTIR spectrometer for time resolved successive spectra. Furthermore, the volatiles are flushed out from the ampoule with dry N2 carrier gas and are then quantified through spectral and time integration. This method is sufficiently sensitive to determine absolute yields of ~50 μg water or CO 2, which relates to probing mass losses of less than 0.01% for a 1 g sample, i.e. the early stages in the degradation process. Such quantitative gas analysis is not easily achieved with other approaches. Our approach opens up the possibility of quantitative monitoring of volatile evolution as an avenue to explore polymer degradation kinetics and its dependence on time and temperature.« less

  20. High temperature polymer degradation: Rapid IR flow-through method for volatile quantification

    DOE PAGES

    Giron, Nicholas H.; Celina, Mathew C.

    2017-05-19

    Accelerated aging of polymers at elevated temperatures often involves the generation of volatiles. These can be formed as the products of oxidative degradation reactions or intrinsic pyrolytic decomposition as part of polymer scission reactions. A simple analytical method for the quantification of water, CO 2, and CO as fundamental signatures of degradation kinetics is required. Here, we describe an analytical framework and develops a rapid mid-IR based gas analysis methodology to quantify volatiles that are contained in small ampoules after aging exposures. The approach requires identification of unique spectral signatures, systematic calibration with known concentrations of volatiles, and a rapidmore » acquisition FTIR spectrometer for time resolved successive spectra. Furthermore, the volatiles are flushed out from the ampoule with dry N2 carrier gas and are then quantified through spectral and time integration. This method is sufficiently sensitive to determine absolute yields of ~50 μg water or CO 2, which relates to probing mass losses of less than 0.01% for a 1 g sample, i.e. the early stages in the degradation process. Such quantitative gas analysis is not easily achieved with other approaches. Our approach opens up the possibility of quantitative monitoring of volatile evolution as an avenue to explore polymer degradation kinetics and its dependence on time and temperature.« less

  1. Construction Method of Analytical Solutions to the Mathematical Physics Boundary Problems for Non-Canonical Domains

    NASA Astrophysics Data System (ADS)

    Mobarakeh, Pouyan Shakeri; Grinchenko, Victor T.

    2015-06-01

    The majority of practical cases of acoustics problems requires solving the boundary problems in non-canonical domains. Therefore construction of analytical solutions of mathematical physics boundary problems for non-canonical domains is both lucrative from the academic viewpoint, and very instrumental for elaboration of efficient algorithms of quantitative estimation of the field characteristics under study. One of the main solving ideologies for such problems is based on the superposition method that allows one to analyze a wide class of specific problems with domains which can be constructed as the union of canonically-shaped subdomains. It is also assumed that an analytical solution (or quasi-solution) can be constructed for each subdomain in one form or another. However, this case implies some difficulties in the construction of calculation algorithms, insofar as the boundary conditions are incompletely defined in the intervals, where the functions appearing in the general solution are orthogonal to each other. We discuss several typical examples of problems with such difficulties, we study their nature and identify the optimal methods to overcome them.

  2. Quantitative analysis of the pendulum test: application to multiple sclerosis patients treated with botulinum toxin.

    PubMed

    Bianchi, L; Monaldi, F; Paolucci, S; Iani, C; Lacquaniti, F

    1999-01-01

    The aim of this study was to develop quantitative analytical methods in the application of the pendulum test to both normal and spastic subjects. The lower leg was released by a torque motor from different starting positions. The resulting changes in the knee angle were fitted by means of a time-varying model. Stiffness and viscosity coefficients were derived for each half-cycle oscillation in both flexion and extension, and for all knee starting positions. This method was applied to the assessment of the effects of Botulinum toxin A (BTX) in progressive multiple sclerosis patients in a follow-up study. About half of the patients showed a significant decrement in stiffness and viscosity coefficients.

  3. Measurement of sulfur-containing compounds involved in the metabolism and transport of cysteamine and cystamine. Regional differences in cerebral metabolism☆

    PubMed Central

    Pinto, John T.; Khomenko, Tetyana; Szabo, Sandor; McLaren, Gordon D.; Denton, Travis T.; Krasnikov, Boris F.; Jeitner, Thomas M.; Cooper, Arthur J.L.

    2009-01-01

    An HPLC method with coulometric detection is presented for the quantitation of cysteamine, cystamine, thialysine, glutathione, glutathione disulfide and an oxidized metabolite of thialysine [S-(2-aminoethyl)-l-cysteine ketimine decarboxylated dimer (AECK-DD)]. The advantage of coulometric detection is that derivatization is unnecessary if the analyte is redox sensitive. The method was used to quantitate several sulfur-containing compounds in plasma and brain following gavage feeding of cysteamine to rats. Cysteamine, cystamine, thialysine and AECK-DD were detected in the brains of these animals. Interestingly, cysteamine treatment resulted in greatly elevated levels of cerebral methionine, despite the fact that cysteamine is not a precursor of methionine. PMID:19523884

  4. Improved quality control of [18F]fluoromethylcholine.

    PubMed

    Nader, Michael; Reindl, Dietmar; Eichinger, Reinhard; Beheshti, Mohsen; Langsteger, Werner

    2011-11-01

    With respect to the broad application of [(18)F-methyl]fluorocholine (FCH), there is a need for a safe, but also efficient and convenient way for routine quality control of FCH. Therefore, a GC- method should be developed and validated which allows the simultaneous quantitation of all chemical impurities and residual solvents such as acetonitrile, ethanol, dibromomethane and N,N-dimethylaminoethanol. Analytical GC has been performed with a GC-capillary column Optima 1701 (50 m×0.32 mm), and a pre-column deactivated capillary column phenyl-Sil (10 m×0.32) in line with a flame ionization detector (FID) was used. The validation includes the following tests: specificity, range, accuracy, linearity, precision, limit of detection (LOD) and limit of quantitation (LOQ) of all listed substances. The described GC method has been successfully used for the quantitation of the listed chemical impurities. The specificity of the GC separation has been proven by demonstrating that the appearing peaks are completely separated from each other and that a resolution R≥1.5 for the separation of the peaks could be achieved. The specified range confirmed that the analytical procedure provides an acceptable degree of linearity, accuracy and precision. For each substance, a range from 2% to 120% of the specification limit could be demonstrated. The corresponding LOD values were determined and were much lower than the specification limits. An efficient and convenient GC method for the quality control of FCH has been developed and validated which meets all acceptance criteria in terms of linearity, specificity, precision, accuracy, LOD and LOQ. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. Rapid quantitative analysis of methylphenidate and ritalinic acid in oral fluid by liquid chromatography triple quadrupole mass spectrometry (LC-QqQ-MS).

    PubMed

    Mulet, Carmen T; Arroyo-Mora, Luis E; Leon, Lorena A; Gnagy, Elizabeth; DeCaprio, Anthony P

    2018-06-20

    Methylphenidate (MPH), which is metabolized into ritalinic acid (RA), is an amphetamine derivative largely used in the treatment of attention-deficit hyperactivity disorder, a neurological condition commonly diagnosed in early childhood. Ensuring that patients comply with clinical treatment is crucial and compliance is generally monitored in blood or urine specimens which, especially in the case of children, can be challenging to obtain on a repetitive basis. Here we report validation of a specific, non-invasive, and rapid dilute-and-shoot analytical method for the detection and quantitation of MPH and RA in oral fluid (OF). The method is based on liquid chromatography coupled to triple quadrupole MS with electrospray ionization utilizing dynamic MRM mode. Subject OF specimens were collected using a Quantisal™ device, processed, and diluted for analysis with seven-point quadratic calibration curves (weighting of 1/x) using MPH-d 9 and (±)-threo-RA-d 10 as internal standards. QC samples and diluted specimens showed intra- and inter-day bias and imprecision values no greater than ±12%. The LOD and LOQ for MPH were 0.1 and 0.5 ng/mL, respectively, and 0.2 ng/mL and 0.5 ng/mL for RA, respectively, indicating the validity of the method for identification and confirmation at low concentrations. Selectivity was specific for the analytes of interest and matrix effects were minimized through the use of internal standard based quantitation. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Quantitative analysis of drugs in hair by UHPLC high resolution mass spectrometry.

    PubMed

    Kronstrand, Robert; Forsman, Malin; Roman, Markus

    2018-02-01

    Liquid chromatographic methods coupled to high resolution mass spectrometry are increasingly used to identify compounds in various matrices including hair but there are few recommendations regarding the parameters and their criteria to identify a compound. In this study we present a method for the identification and quantification of a range of drugs and discuss the parameters used to identify a compound with high resolution mass spectrometry. Drugs were extracted from hair by incubation in a buffer:solvent mixture at 37°C during 18h. Analysis was performed on a chromatographic system comprised of an Agilent 6550 QTOF coupled to a 1290 Infinity UHPLC system. High resolution accurate mass data were acquired in the All Ions mode and exported into Mass Hunter Quantitative software for quantitation and identification using qualifier fragment ions. Validation included selectivity, matrix effects, calibration range, within day and between day precision and accuracy. The analytes were 7-amino-flunitrazepam, 7-amino-clonazepam, 7-amino-nitrazepam, acetylmorphine, alimemazine, alprazolam, amphetamine, benzoylecgonine, buprenorphine, diazepam, ethylmorphine, fentanyl, hydroxyzine, ketobemidone, codeine, cocaine, MDMA, methadone, methamphetamine, morphine, oxycodone, promethazine, propiomazine, propoxyphene, tramadol, zaleplone, zolpidem, and zopiclone. As proof of concept, hair from 29 authentic post mortem cases were analysed. The calibration range was established between 0.05ng/mg to 5.0ng/mg for all analytes except fentanyl (0.02-2.0), buprenorphine (0.04-2.0), and ketobemidone (0.05-4.0) as well as for alimemazine, amphetamine, cocaine, methadone, and promethazine (0.10-5.0). For all analytes, the accuracy of the fortified pooled hair matrix was 84-108% at the low level and 89-106% at the high level. The within series precisions were between 1.4 and 6.7% and the between series precisions were between 1.4 and 10.1%. From the 29 autopsy cases, 121 positive findings were encountered from 23 of the analytes in concentrations similar to those previously published. We conclude that the developed method proved precise and accurate and that it had sufficient performance for the purpose of detecting regular use of drugs or treatment with prescription drugs. To identify a compound we recommend the use of ion ratios as a complement to instrument software "matching scores". Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Quantitative Analysis of Fullerene Nanomaterials in Environmental Systems: A Critical Review

    PubMed Central

    Isaacson, Carl W.; Kleber, Markus; Field, Jennifer A.

    2009-01-01

    The increasing production and use of fullerene nanomaterials has led to calls for more information regarding the potential impacts that releases of these materials may have on human and environmental health. Fullerene nanomaterials, which are comprised of both fullerenes and surface-functionalized fullerenes, are used in electronic, optic, medical and cosmetic applications. Measuring fullerene nanomaterial concentrations in natural environments is difficult because they exhibit a duality of physical and chemical characteristics as they transition from hydrophobic to polar forms upon exposure to water. In aqueous environments, this is expressed as their tendency to initially (i) self assemble into aggregates of appreciable size and hydrophobicity, and subsequently (ii) interact with the surrounding water molecules and other chemical constituents in natural environments thereby acquiring negative surface charge. Fullerene nanomaterials may therefore deceive the application of any single analytical method that is applied with the assumption that fullerenes have but one defining characteristic (e.g., hydrophobicity). [1] We find that analytical procedures are needed to account for the potentially transitory nature of fullerenes in natural environments through the use of approaches that provide chemically-explicit information including molecular weight and the number and identity of surface functional groups. [2] We suggest that sensitive and mass-selective detection, such as that offered by mass spectrometry when combined with optimized extraction procedures, offers the greatest potential to achieve this goal. [3] With this review, we show that significant improvements in analytical rigor would result from an increased availability of well characterized authentic standards, reference materials, and isotopically-labeled internal standards. Finally, the benefits of quantitative and validated analytical methods for advancing the knowledge on fullerene occurrence, fate, and behavior are indicated. PMID:19764203

  8. Quantitative Electron Probe Microanalysis: State of the Art

    NASA Technical Reports Server (NTRS)

    Carpernter, P. K.

    2005-01-01

    Quantitative electron-probe microanalysis (EPMA) has improved due to better instrument design and X-ray correction methods. Design improvement of the electron column and X-ray spectrometer has resulted in measurement precision that exceeds analytical accuracy. Wavelength-dispersive spectrometer (WDS) have layered-dispersive diffraction crystals with improved light-element sensitivity. Newer energy-dispersive spectrometers (EDS) have Si-drift detector elements, thin window designs, and digital processing electronics with X-ray throughput approaching that of WDS Systems. Using these systems, digital X-ray mapping coupled with spectrum imaging is a powerful compositional mapping tool. Improvements in analytical accuracy are due to better X-ray correction algorithms, mass absorption coefficient data sets,and analysis method for complex geometries. ZAF algorithms have ban superceded by Phi(pz) algorithms that better model the depth distribution of primary X-ray production. Complex thin film and particle geometries are treated using Phi(pz) algorithms, end results agree well with Monte Carlo simulations. For geological materials, X-ray absorption dominates the corretions end depends on the accuracy of mass absorption coefficient (MAC) data sets. However, few MACs have been experimentally measured, and the use of fitted coefficients continues due to general success of the analytical technique. A polynomial formulation of the Bence-Albec alpha-factor technique, calibrated using Phi(pz) algorithms, is used to critically evaluate accuracy issues and can be also be used for high 2% relative and is limited by measurement precision for ideal cases, but for many elements the analytical accuracy is unproven. The EPMA technique has improved to the point where it is frequently used instead of the petrogaphic microscope for reconnaissance work. Examples of stagnant research areas are: WDS detector design characterization of calibration standards, and the need for more complete treatment of the continuum X-ray fluorescence correction.

  9. Comprehensive analytical strategy for biomonitoring of pesticides in urine by liquid chromatography–orbitrap high resolution masss pectrometry.

    PubMed

    Roca, M; Leon, N; Pastor, A; Yusà, V

    2014-12-29

    In this study we propose an analytical strategy that combines a target approach for the quantitative analysis of contemporary pesticide metabolites with a comprehensive post-target screening for the identification of biomarkers of exposure to environmental contaminants in urine using liquid chromatography coupled to high-resolution mass spectrometry (LC–HRMS). The quantitative method for the target analysis of 29 urinary metabolites of organophosphate (OP) insecticides, synthetic pyrethroids, herbicides and fungicides was validated after a previous statistical optimization of the main factors governing the ion source ionization and a fragmentation study using the high energy collision dissociation (HCD) cell. The full scan accurate mass data were acquired with a resolving power of 50,000 FWHM (scan speed, 2 Hz), in both ESI+ and ESI− modes, and with and without HCD-fragmentation. The method – LOQ was lower than 3.2 μg L−1 for the majority of the analytes. For post-target screening a customized theoretical database was built, for the identification of 60 metabolites including pesticides, PAHs, phenols, and other metabolites of environmental pollutants. For identification purposes, accurate exact mass with less than 5 ppm, and diagnostic ions including isotopes and/or fragments were used. The analytical strategy was applied to 20 urine sample collected from children living in Valencia Region. Eleven target metabolites were detected with concentrations ranging from 1.18 to 131 μg L−1. Likewise, several compounds were tentatively identified in the post-target analysis belonging to the families of phthalates, phenols and parabenes. The proposed strategy is suitable for the determination of target pesticide biomarkers in urine in the framework of biomonitoring studies, and appropriate for the identification of other non-target metabolites.

  10. Quantitative LC-MS/MS analysis of seven ginsenosides and three aconitum alkaloids in Shen-Fu decoction

    PubMed Central

    2013-01-01

    Background Shen-Fu decoction is a traditional Chinese medicine prescription with a 3:2 ratio of Radix Ginseng and Fuzi (Radix Aconiti lateralis praeparata). Ginsenosides and alkaloids are considered to be the main active components of Shen-Fu decoction. However, no analytical methods have been used to quantitatively analyse both components in Shen-Fu decoction simultaneously. Results We successfully developed a rapid resolution liquid chromatography coupled with tandem mass spectrometry (RRLC-MS/MS) method for the simultaneous analysis of seven ginsenosides and three aconitum alkaloids in Shen-Fu decoction, the decoction of Radix ginseng and Fuzi (Radix Aconiti lateralis praeparata). Chromatogrpahic separation by RPLC was achieved using a reversed-phase column and a water/acetonitrile mobile phase, containing 0.05% formic acid and using a gradient system. The method was optimized to allow for simultaneous analysis of all analytes in 11minutes without the need for baseline resolution of the components. Furthermore, the separation demonstrated good linearity (r > 0.9882), repeatability (RSD < 7.01%), intra- and inter-day precisions (RSD < 5.06%) and high yields of recovery (91.13-111.97%) for ten major constituents, namely ginsenoside-Re, Rg1, Rb1, Rc, Rb2, Rd, Rf, aconitine, hypacoitine and mesaconitine. Conclusions The developed method could be used as a rapid and reliable approach for assessment of the quantity of the major constituents in Shen-Fu decoction. PMID:24107599

  11. Determination of Sodium, Potassium, Magnesium, and Calcium Minerals Level in Fresh and Boiled Broccoli and Cauliflower by Atomic Absorption Spectrometry

    NASA Astrophysics Data System (ADS)

    Nerdy

    2018-01-01

    Vegetables from the cabbage family vegetables consumed by many people, which is known healthful, by eaten raw, boiled, or cooked (stir fry or soup). Vegetables like broccoli and cauliflower contain vitamins, minerals, and fiber. This study aims to determine the decrease percentage of sodium, potassium, magnesium, and calcium minerals level caused by boiled broccoli and cauliflower by atomic absorption spectrometry. Boiled broccoli and cauliflower prepared by given boiled treatment in boiling water for 3 minutes. Fresh and boiled broccoli and cauliflower carried out dry destruction, followed by quantitative analysis of sodium, potassium, magnesium, and calcium minerals respectively at a wavelength of 589.0 nm; 766.5 nm; 285.2 nm; and 422.7 nm, using atomic absorption spectrometry methods. After the determination of the sodium, potassium, magnesium, and calcium minerals level followed by validation of analytical methods with accuracy, precision, linearity, range, limit of detection (LOD), and limit of quantitation (LOQ) parameters. Research results show a decrease in the sodium, potassium, magnesium, and calcium minerals level in boiled broccoli and cauliflower compared with fresh broccoli and cauliflower. Validation of analytical methods gives results that spectrometry methods used for determining sodium, potassium, magnesium, and calcium minerals level are valid. It concluded that the boiled gives the effect of decreasing the minerals level significantly in broccoli and cauliflower.

  12. Compensation of matrix effects in gas chromatography-mass spectrometry analysis of pesticides using a combination of matrix matching and multiple isotopically labeled internal standards.

    PubMed

    Tsuchiyama, Tomoyuki; Katsuhara, Miki; Nakajima, Masahiro

    2017-11-17

    In the multi-residue analysis of pesticides using GC-MS, the quantitative results are adversely affected by a phenomenon known as the matrix effect. Although the use of matrix-matched standards is considered to be one of the most practical solutions to this problem, complete removal of the matrix effect is difficult in complex food matrices owing to their inconsistency. As a result, residual matrix effects can introduce analytical errors. To compensate for residual matrix effects, we have developed a novel method that employs multiple isotopically labeled internal standards (ILIS). The matrix effects of ILIS and pesticides were evaluated in spiked matrix extracts of various agricultural commodities, and the obtained data were subjected to simple statistical analysis. Based on the similarities between the patterns of variation in the analytical response, a total of 32 isotopically labeled compounds were assigned to 338 pesticides as internal standards. It was found that by utilizing multiple ILIS, residual matrix effects could be effectively compensated. The developed method exhibited superior quantitative performance compared with the common single-internal-standard method. The proposed method is more feasible for regulatory purposes than that using only predetermined correction factors and is considered to be promising for practical applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Quantitative analysis of virgin coconut oil in cream cosmetics preparations using fourier transform infrared (FTIR) spectroscopy.

    PubMed

    Rohman, A; Man, Yb Che; Sismindari

    2009-10-01

    Today, virgin coconut oil (VCO) is becoming valuable oil and is receiving an attractive topic for researchers because of its several biological activities. In cosmetics industry, VCO is excellent material which functions as a skin moisturizer and softener. Therefore, it is important to develop a quantitative analytical method offering a fast and reliable technique. Fourier transform infrared (FTIR) spectroscopy with sample handling technique of attenuated total reflectance (ATR) can be successfully used to analyze VCO quantitatively in cream cosmetic preparations. A multivariate analysis using calibration of partial least square (PLS) model revealed the good relationship between actual value and FTIR-predicted value of VCO with coefficient of determination (R2) of 0.998.

  14. Using Interactive Data Visualizations for Exploratory Analysis in Undergraduate Genomics Coursework: Field Study Findings and Guidelines

    NASA Astrophysics Data System (ADS)

    Mirel, Barbara; Kumar, Anuj; Nong, Paige; Su, Gang; Meng, Fan

    2016-02-01

    Life scientists increasingly use visual analytics to explore large data sets and generate hypotheses. Undergraduate biology majors should be learning these same methods. Yet visual analytics is one of the most underdeveloped areas of undergraduate biology education. This study sought to determine the feasibility of undergraduate biology majors conducting exploratory analysis using the same interactive data visualizations as practicing scientists. We examined 22 upper level undergraduates in a genomics course as they engaged in a case-based inquiry with an interactive heat map. We qualitatively and quantitatively analyzed students' visual analytic behaviors, reasoning and outcomes to identify student performance patterns, commonly shared efficiencies and task completion. We analyzed students' successes and difficulties in applying knowledge and skills relevant to the visual analytics case and related gaps in knowledge and skill to associated tool designs. Findings show that undergraduate engagement in visual analytics is feasible and could be further strengthened through tool usability improvements. We identify these improvements. We speculate, as well, on instructional considerations that our findings suggested may also enhance visual analytics in case-based modules.

  15. Using Interactive Data Visualizations for Exploratory Analysis in Undergraduate Genomics Coursework: Field Study Findings and Guidelines

    PubMed Central

    Kumar, Anuj; Nong, Paige; Su, Gang; Meng, Fan

    2016-01-01

    Life scientists increasingly use visual analytics to explore large data sets and generate hypotheses. Undergraduate biology majors should be learning these same methods. Yet visual analytics is one of the most underdeveloped areas of undergraduate biology education. This study sought to determine the feasibility of undergraduate biology majors conducting exploratory analysis using the same interactive data visualizations as practicing scientists. We examined 22 upper level undergraduates in a genomics course as they engaged in a case-based inquiry with an interactive heat map. We qualitatively and quantitatively analyzed students’ visual analytic behaviors, reasoning and outcomes to identify student performance patterns, commonly shared efficiencies and task completion. We analyzed students’ successes and difficulties in applying knowledge and skills relevant to the visual analytics case and related gaps in knowledge and skill to associated tool designs. Findings show that undergraduate engagement in visual analytics is feasible and could be further strengthened through tool usability improvements. We identify these improvements. We speculate, as well, on instructional considerations that our findings suggested may also enhance visual analytics in case-based modules. PMID:26877625

  16. Determination of iodinated X-ray contrast media in sewage by solid-phase extraction and liquid chromatography tandem mass spectrometry.

    PubMed

    Echeverría, S; Borrull, F; Fontanals, N; Pocurull, E

    2013-11-15

    A method for the quantitative determination of five iodinated X-ray contrast media (ICMs) in sewage was developed by solid-phase extraction and high-performance liquid chromatography-tandem mass spectrometry. A fused-core analytical column was successfully applied for the first time for the separation of ICMs. Oasis HLB was selected from the sorbents tested because of its higher recoveries. The optimized method allowed the determination of the ICMs at low ng/L levels in both influent and effluent sewage, with detection limits of 40 ng/L and 10 ng/L for most compounds in influent and effluent sewage, respectively. The five ICMs studied were determined in all samples analysed, with iopromide being the analyte found at the highest concentration (8.9 µg/L), while iopamidol was the analyte found at lowest concentration (1.3 µg/L) in influent sewage. Effluent sewage did not show a significant decrease in ICM concentrations. © 2013 Elsevier B.V. All rights reserved.

  17. Reverse phase protein microarrays: fluorometric and colorimetric detection.

    PubMed

    Gallagher, Rosa I; Silvestri, Alessandra; Petricoin, Emanuel F; Liotta, Lance A; Espina, Virginia

    2011-01-01

    The Reverse Phase Protein Microarray (RPMA) is an array platform used to quantitate proteins and their posttranslationally modified forms. RPMAs are applicable for profiling key cellular signaling pathways and protein networks, allowing direct comparison of the activation state of proteins from multiple samples within the same array. The RPMA format consists of proteins immobilized directly on a nitrocellulose substratum. The analyte is subsequently probed with a primary antibody and a series of reagents for signal amplification and detection. Due to the diversity, low concentration, and large dynamic range of protein analytes, RPMAs require stringent signal amplification methods, high quality image acquisition, and software capable of precisely analyzing spot intensities on an array. Microarray detection strategies can be either fluorescent or colorimetric. The choice of a detection system depends on (a) the expected analyte concentration, (b) type of microarray imaging system, and (c) type of sample. The focus of this chapter is to describe RPMA detection and imaging using fluorescent and colorimetric (diaminobenzidine (DAB)) methods.

  18. Investigation of the "true" extraction recovery of analytes from multiple types of tissues and its impact on tissue bioanalysis using two model compounds.

    PubMed

    Yuan, Long; Ma, Li; Dillon, Lisa; Fancher, R Marcus; Sun, Huadong; Zhu, Mingshe; Lehman-McKeeman, Lois; Aubry, Anne-Françoise; Ji, Qin C

    2016-11-16

    LC-MS/MS has been widely applied to the quantitative analysis of tissue samples. However, one key remaining issue is that the extraction recovery of analyte from spiked tissue calibration standard and quality control samples (QCs) may not accurately represent the "true" recovery of analyte from incurred tissue samples. This may affect the accuracy of LC-MS/MS tissue bioanalysis. Here, we investigated whether the recovery determined using tissue QCs by LC-MS/MS can accurately represent the "true" recovery from incurred tissue samples using two model compounds: BMS-986104, a S1P 1 receptor modulator drug candidate, and its phosphate metabolite, BMS-986104-P. We first developed a novel acid and surfactant assisted protein precipitation method for the extraction of BMS-986104 and BMS-986104-P from rat tissues, and determined their recoveries using tissue QCs by LC-MS/MS. We then used radioactive incurred samples from rats dosed with 3 H-labeled BMS-986104 to determine the absolute total radioactivity recovery in six different tissues. The recoveries determined using tissue QCs and incurred samples matched with each other very well. The results demonstrated that, in this assay, tissue QCs accurately represented the incurred tissue samples to determine the "true" recovery, and LC-MS/MS assay was accurate for tissue bioanalysis. Another aspect we investigated is how the tissue QCs should be prepared to better represent the incurred tissue samples. We compared two different QC preparation methods (analyte spiked in tissue homogenates or in intact tissues) and demonstrated that the two methods had no significant difference when a good sample preparation was in place. The developed assay showed excellent accuracy and precision, and was successfully applied to the quantitative determination of BMS-986104 and BMS-986104-P in tissues in a rat toxicology study. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Validated UPLC-MS/MS Methods To Quantitate Free and Conjugated Alternaria Toxins in Commercially Available Tomato Products and Fruit and Vegetable Juices in Belgium.

    PubMed

    Walravens, Jeroen; Mikula, Hannes; Rychlik, Michael; Asam, Stefan; Devos, Tom; Njumbe Ediage, Emmanuel; Diana Di Mavungu, José; Jacxsens, Liesbeth; Van Landschoot, Anita; Vanhaecke, Lynn; De Saeger, Sarah

    2016-06-22

    Ultraperformance liquid chromatography tandem mass spectrometry and Quick, Easy, Cheap, Effective, Rugged, and Safe based analytical methodologies to quantitate both free (alternariol (1), alternariol monomethyl ether (2), tenuazonic acid (3), tentoxin (4), altenuene (5), altertoxin-I (6)) and conjugated (sulfates and glucosides of 1 and 2) Alternaria toxins in fruit and vegetable juices and tomato products were developed and validated. Acceptable limits of quantitation (0.7-5.7 μg/kg), repeatability (RSDr < 15.7%), reproducibility (RSDR < 17.9%), and apparent recovery (87.0-110.6%) were obtained for all analytes in all matrices investigated. 129 commercial foodstuffs were analyzed, and 3 was detected in 100% of tomato product samples (

  20. A new method for the determination of short-chain fatty acids from the aliphatic series in wines by headspace solid-phase microextraction-gas chromatography-ion trap mass spectrometry.

    PubMed

    Olivero, Sergio J Pérez; Trujillo, Juan P Pérez

    2011-06-24

    A new analytical method for the determination of nine short-chain fatty acids (acetic, propionic, isobutyric, butyric, isovaleric, 2-methylbutyric, hexanoic, octanoic and decanoic acids) in wines using the automated HS/SPME-GC-ITMS technique was developed and optimised. Five different SPME fibers were tested and the influence of different factors such as temperature and time of extraction, temperature and time of desorption, pH, strength ionic, tannins, anthocyans, SO(2), sugar and ethanol content were studied and optimised using model solutions. Some analytes showed matrix effect so a study of recoveries was performed. The proposed HS/SPME-GC-ITMS method, that covers the concentration range of the different analytes in wines, showed wide linear ranges, values of repeatability and reproducibility lower than 4.0% of RSD and detection limits between 3 and 257 μgL(-1), lower than the olfactory thresholds. The optimised method is a suitable technique for the quantitative analysis of short-chain fatty acids from the aliphatic series in real samples of white, rose and red wines. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Quantitative Evaluation of Aged AISI 316L Stainless Steel Sensitization to Intergranular Corrosion: Comparison Between Microstructural Electrochemical and Analytical Methods

    NASA Astrophysics Data System (ADS)

    Sidhom, H.; Amadou, T.; Sahlaoui, H.; Braham, C.

    2007-06-01

    The evaluation of the degree of sensitization (DOS) to intergranular corrosion (IGC) of a commercial AISI 316L austenitic stainless steel aged at temperatures ranging from 550 °C to 800 °C during 100 to 80,000 hours was carried out using three different assessment methods. (1) The microstructural method coupled with the Strauss standard test (ASTM A262). This method establishes the kinetics of the precipitation phenomenon under different aging conditions, by transmission electronic microscope (TEM) examination of thin foils and electron diffraction. The subsequent chromium-depleted zones are characterized by X-ray microanalysis using scanning transmission electronic microscope (STEM). The superimposition of microstructural time-temperature-precipitation (TTP) and ASTM A262 time-temperature-sensitization (TTS) diagrams provides the relationship between aged microstructure and IGC. Moreover, by considering the chromium-depleted zone characteristics, sensitization and desensitization criteria could be established. (2) The electrochemical method involving the double loop-electrochemical potentiokinetic reactivation (DL-EPR) test. The operating conditions of this test were initially optimized using the experimental design method on the bases of the reliability, the selectivity, and the reproducibility of test responses for both annealed and sensitized steels. The TTS diagram of the AISI 316L stainless steel was established using this method. This diagram offers a quantitative assessment of the DOS and a possibility to appreciate the time-temperature equivalence of the IGC sensitization and desensitization. (3) The analytical method based on the chromium diffusion models. Using the IGC sensitization and desensitization criteria established by the microstructural method, numerical solving of the chromium diffusion equations leads to a calculated AISI 316L TTS diagram. Comparison of these three methods gives a clear advantage to the nondestructive DL-EPR test when it is used with its optimized operating conditions. This quantitative method is simple to perform; it is fast, reliable, economical, and presents the best ability to detect the lowest DOS to IGC. For these reasons, this method can be considered as a serious candidate for IGC checking of stainless steel components of industrial plants.

  2. Topiramate: A Review of Analytical Approaches for the Drug Substance, Its Impurities and Pharmaceutical Formulations.

    PubMed

    Pinto, Eduardo Costa; Dolzan, Maressa Danielli; Cabral, Lucio Mendes; Armstrong, Daniel W; de Sousa, Valéria Pereira

    2016-02-01

    An important step during the development of high-performance liquid chromatography (HPLC) methods for quantitative analysis of drugs is choosing the appropriate detector. High sensitivity, reproducibility, stability, wide linear range, compatibility with gradient elution, non-destructive detection of the analyte and response unaffected by changes in the temperature/flow are some of the ideal characteristics of a universal HPLC detector. Topiramate is an anticonvulsant drug mainly used for the treatment of different types of seizures and prophylactic treatment of migraine. Different analytical approaches to quantify topiramate by HPLC have been described because of the lack of chromophoric moieties on its structure, such as derivatization with fluorescent moieties and UV-absorbing moieties, conductivity detection, evaporative light scattering detection, refractive index detection, chemiluminescent nitrogen detection and MS detection. Some methods for the determination of topiramate by capillary electrophoresis and gas chromatography have also been published. This systematic review provides a description of the main analytical methods presented in the literature to analyze topiramate in the drug substance and in pharmaceutical formulations. Each of these methods is briefly discussed, especially considering the detector used with HPLC. In addition, this article presents a review of the data available regarding topiramate stability, degradation products and impurities. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. [Liquid chromatography-tandem mass spectrometry method for determination of 10 macrolide antibiotics in pork samples using on-line solid phase extraction purification].

    PubMed

    Zhang, Xiaoguang; Liu, Dong; Liu, Hongran; Li, Qiang; Li, Lili; Wang, Lixia; Zhang, Yan

    2017-10-08

    A high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method based on-line solid phase extraction (SPE) purification was established to determine 10 macrolide antibiotics in pork samples. The samples were extracted with acetonitrile, and the extracts were dried with rotary evaporator at 40℃, then the analytes were dissolved with 2 mL phosphate buffer. The solutions were purified and concentrated by on-line SPE with HLB cartridges. The analytes were eluted with methanol, and then transferred to XBridge BEH C18 column, separated with the mobile phases of 10 mmol/L ammonium acetate aqueous solution and acetonitrile. Finally, the target analytes were detected by tandem mass spectrometry. The results showed that good linearity was obtained in the range of 0.1-200 μg/L for the 10 macrolide antibiotics with correlation coefficients better than 0.990. The limits of detection were in range of 0.05-0.30 μg/kg and the limits of quantitation were in range of 0.10-1.00 μg/kg. The recoveries of the method were in range of 69.6%-115.2% at the spiked levels of 0.10-10.0 μg/kg for all analytes, with the relative standard deviations less than 10%. The developed method can be used for the determination of the 10 macrolide antibiotics in pork samples.

  4. Differential reliability : probabilistic engineering applied to wood members in bending-tension

    Treesearch

    Stanley K. Suddarth; Frank E. Woeste; William L. Galligan

    1978-01-01

    Reliability analysis is a mathematical technique for appraising the design and materials of engineered structures to provide a quantitative estimate of probability of failure. Two or more cases which are similar in all respects but one may be analyzed by this method; the contrast between the probabilities of failure for these cases allows strong analytical focus on the...

  5. Content-Related Issues Pertaining to Teaching Statistics: Making Decisions about Educational Objectives in Statistics Courses.

    ERIC Educational Resources Information Center

    Bliss, Leonard B.; Tashakkori, Abbas

    This paper discusses the objectives that would be appropriate for statistics classes for students who are not majoring in statistics, evaluation, or quantitative research design. These "non-majors" should be able to choose appropriate analytical methods for specific sets of data based on the research question and the nature of the data, and they…

  6. Structural Uncertainties in Numerical Induction Models

    DTIC Science & Technology

    2006-07-01

    divide and conquer” modelling approach. Analytical inputs are then assessments, quantitative or qualitative, of the value, performance, or some...said to be naïve because it relies heavily on the inductive method itself. Sophisticated Induction (Logical Positivism ) This form of induction...falters. Popper’s Falsification Karl Popper around 1959 introduced a variant to the above Logical Positivism , known as the inductive-hypothetico

  7. Paper-based microfluidic sensing device for label-free immunoassay demonstrated by biotin-avidin binding interaction.

    PubMed

    Lei, Kin Fong; Yang, Shih-I; Tsai, Shiao-Wen; Hsu, Hsiao-Ting

    2015-03-01

    Efficient diagnosis is very important for the prevention and treatment of diseases. Rapid disease screening in ambulatory environment is one of the most pressing needs for disease control. Despite there are many methods to detect the results of immunoassays, quantitative measurement for rapid disease screening is still a great challenge for point-of-care applications. In this study, a fabrication method for depositing carbon nanotube bundles has been successfully developed for realization of functional paper-based microfluidic sensing device. Quantitative detection of label-free immunoassay, i.e., biotin-avidin binding interaction, was demonstrated by direct measurement of the current change of the biosensor after single application of the target analyte. Sensitivity of 0.33 μA/ng mL(-1) and minimal detectable analyte concentration of 25 ng/mL were achieved. The time necessary for the detection was 500 s which is a large reduction compared with the conventional immunoassay. Such paper-based biosensor has the benefits of portability, fast response, simple operation, and low cost and has the potential for the development of rapid disease screening devices. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Validation of Direct Analysis Real Time source/Time-of-Flight Mass Spectrometry for organophosphate quantitation on wafer surface.

    PubMed

    Hayeck, Nathalie; Ravier, Sylvain; Gemayel, Rachel; Gligorovski, Sasho; Poulet, Irène; Maalouly, Jacqueline; Wortham, Henri

    2015-11-01

    Microelectronic wafers are exposed to airborne molecular contamination (AMC) during the fabrication process of microelectronic components. The organophosphate compounds belonging to the dopant group are one of the most harmful groups. Once adsorbed on the wafer surface these compounds hardly desorb and could diffuse in the bulk of the wafer and invert the wafer from p-type to n-type. The presence of these compounds on wafer surface could have electrical effect on the microelectronic components. For these reasons, it is of importance to control the amount of these compounds on the surface of the wafer. As a result, a fast quantitative and qualitative analytical method, nondestructive for the wafers, is needed to be able to adjust the process and avoid the loss of an important quantity of processed wafers due to the contamination by organophosphate compounds. Here we developed and validated an analytical method for the determination of organic compounds adsorbed on the surface of microelectronic wafers using the Direct Analysis in Real Time-Time of Flight-Mass Spectrometry (DART-ToF-MS) system. Specifically, the developed methodology concerns the organophosphate group. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Mycotoxin Analysis of Human Urine by LC-MS/MS: A Comparative Extraction Study

    PubMed Central

    Escrivá, Laura; Font, Guillermina

    2017-01-01

    The lower mycotoxin levels detected in urine make the development of sensitive and accurate analytical methods essential. Three extraction methods, namely salting-out liquid–liquid extraction (SALLE), miniQuEChERS (quick, easy, cheap, effective, rugged, and safe), and dispersive liquid–liquid microextraction (DLLME), were evaluated and compared based on analytical parameters for the quantitative LC-MS/MS measurement of 11 mycotoxins (AFB1, AFB2, AFG1, AFG2, OTA, ZEA, BEA, EN A, EN B, EN A1 and EN B1) in human urine. DLLME was selected as the most appropriate methodology, as it produced better validation results for recovery (79–113%), reproducibility (RSDs < 12%), and repeatability (RSDs < 15%) than miniQuEChERS (71–109%, RSDs <14% and <24%, respectively) and SALLE (70–108%, RSDs < 14% and < 24%, respectively). Moreover, the lowest detection (LODS) and quantitation limits (LOQS) were achieved with DLLME (LODs: 0.005–2 μg L−1, LOQs: 0.1–4 μg L−1). DLLME methodology was used for the analysis of 10 real urine samples from healthy volunteers showing the presence of ENs B, B1 and A1 at low concentrations. PMID:29048356

  10. Simultaneous separation and determination of four uncaria alkaloids by capillary electrophoresis using dual cyclodextrin system.

    PubMed

    Li, Lou; Xu, Liying; Chen, Meng; Zhang, Guangbin; Zhang, Hongfen; Chen, Anjia

    2017-07-15

    The purpose of this study was to develop a simple, quick and precise capillary zone electrophoresis method (CZE) for the separation and determination of uncaria alkaloids using dual cyclodextrins as additives for the separation. The four analytes were baseline separated within 15min at the applied voltage of 15kV with a running buffer (pH 5.7) consisting of 40.0mM phosphate buffer, 161.7mM 2-hydroxypropyl-β-cyclodextrin (HP-β-CD) and 2.21mM mono-(6-ethylenediamine-6-deoxy)-β-cyclodextrin (ED-β-CD). Under the optimum conditions, a good linearity was achieved with correlation coefficients from 0.9989 to 0.9992. The detection limits and the quantitation limits ranged from 0.63 to 0.98μg/mL and from 2.08 to 3.28μg/mL, respectively. Excellent accuracy and precision were obtained. Recoveries of the analytes varied from 97.1 to 103.2%. This method was suitable for the quantitative determination of these alkaloids in the stem with hook of Uncaria rhynchophylla and the formulations of Uncaria rhynchophylla. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Quantitation of Permethylated N-Glycans through Multiple-Reaction Monitoring (MRM) LC-MS/MS

    PubMed Central

    Zhou, Shiyue; Hu, Yunli; DeSantos-Garcia, Janie L.; Mechref, Yehia

    2015-01-01

    The important biological roles of glycans and their implications in disease development and progression have created a demand for the development of sensitive quantitative glycomics methods. Quantitation of glycans existing at low abundance is still analytically challenging. In this study, an N-linked glycans quantitation method using multiple reaction monitoring (MRM) on a triple quadrupole instrument was developed. Optimum normalized collision energy (CE) for both sialylated and fucosylated N-glycan structures was determined to be 30% while it was found to be 35% for either fucosylated or sialylated structures The optimum CE for mannose and complex type N-glycan structures was determined to be 35%. Additionally, the use of three transitions was shown to facilitate reliable quantitation. A total of 88 N-glycan structures in human blood serum were quantified using this MRM approach. Reliable detection and quantitation of these structures was achieved when the equivalence of 0.005 μL of blood serum was analyzed. Accordingly, N-glycans down to the 100th of a μL level can be reliably quantified in pooled human blood serum, spanning a dynamic concentration range of three orders of magnitudes. MRM was also effectively utilized to quantitatively compare the expression of N-glycans derived from brain-targeting breast carcinoma cells (MDA-MB-231BR) and metastatic breast cancer cells (MDA-MB-231). Thus, the described MRM method of permethylated N-glycan structures enables a rapid and reliable identification and quantitation of glycans derived from glycoproteins purified or present in complex biological samples. PMID:25698222

  12. Laser Induced Breakdown Spectroscopy for Elemental Analysis in Environmental, Cultural Heritage and Space Applications: A Review of Methods and Results

    PubMed Central

    Gaudiuso, Rosalba; Dell’Aglio, Marcella; De Pascale, Olga; Senesi, Giorgio S.; De Giacomo, Alessandro

    2010-01-01

    Analytical applications of Laser Induced Breakdown Spectroscopy (LIBS), namely optical emission spectroscopy of laser-induced plasmas, have been constantly growing thanks to its intrinsic conceptual simplicity and versatility. Qualitative and quantitative analysis can be performed by LIBS both by drawing calibration lines and by using calibration-free methods and some of its features, so as fast multi-elemental response, micro-destructiveness, instrumentation portability, have rendered it particularly suitable for analytical applications in the field of environmental science, space exploration and cultural heritage. This review reports and discusses LIBS achievements in these areas and results obtained for soils and aqueous samples, meteorites and terrestrial samples simulating extraterrestrial planets, and cultural heritage samples, including buildings and objects of various kinds. PMID:22163611

  13. Solid-phase extraction of some heavy metal ions on a double-walled carbon nanotube disk and determination by flame atomic absorption spectrometry.

    PubMed

    Karatepe, Aslihan; Soylak, Mustafa; Elçi, Latif

    2011-01-01

    A new preconcentration method was developed for the determination of trace amounts of Cu(II), Fe(III), Pb(II), Ni(II), and Cd(II) on a double-walled carbon nanotube disk. 4-(2-Thiazolylazo) resorcinol was used as a complexing reagent. The effects of parameters, including pH of the solutions, amounts of complexing reagent, eluent type, sample volume, flow rates of solutions, and matrix ions were examined for quantitative recoveries of the studied analyte ions. The retained metal ions were eluted by 2 M HNO3. The LOD values for the analytes were in the range of 0.7-4.4 microg/mL. Natural water samples and standard reference materials were analyzed by the presented method.

  14. Laser induced breakdown spectroscopy for elemental analysis in environmental, cultural heritage and space applications: a review of methods and results.

    PubMed

    Gaudiuso, Rosalba; Dell'Aglio, Marcella; De Pascale, Olga; Senesi, Giorgio S; De Giacomo, Alessandro

    2010-01-01

    Analytical applications of Laser Induced Breakdown Spectroscopy (LIBS), namely optical emission spectroscopy of laser-induced plasmas, have been constantly growing thanks to its intrinsic conceptual simplicity and versatility. Qualitative and quantitative analysis can be performed by LIBS both by drawing calibration lines and by using calibration-free methods and some of its features, so as fast multi-elemental response, micro-destructiveness, instrumentation portability, have rendered it particularly suitable for analytical applications in the field of environmental science, space exploration and cultural heritage. This review reports and discusses LIBS achievements in these areas and results obtained for soils and aqueous samples, meteorites and terrestrial samples simulating extraterrestrial planets, and cultural heritage samples, including buildings and objects of various kinds.

  15. Science meets regulation.

    PubMed

    Bilia, Anna Rita

    2014-12-02

    The European Pharmacopoeia (Ph. Eur.) is a standard reference for both European and non-European countries and defines requirements for the qualitative and quantitative composition of medicines. Herbal drug (HD) monographs state which aspects have to be considered for quality assurance through the relevant chapters "Definition", "Characters", "Identification", "Tests", and "Assay". Identification of botanical material is achieved by macroscopic and microscopic morphology, generally examined by a trained expert. Content or assay is the most difficult area of quality control to perform, since in most herbal drugs the active constituents are unknown and markers should be used which cannot be really related to the quality. The other critical points are represented by the purity tests, in particular some tests such as heavy metals, aflatoxins and pesticides are laborious and time intensive, requiring a significant investment in equipment, materials, and maintenance. A literature survey concerning alternative and/or complementary tools for quality control of botanicals has been performed by searching the scientific databases Pubmed, SciFinder, Scopus and Web of Science. Diverse analytical methods including DNA fingerprinting, Nuclear Magnetic Resonance (NMR), Near Infra Red (NIR) and (bio)sensors have been reported in the literature to evaluate the quality of botanical products. Identification of plants at the species level can be successfully based on genome-based methods, using DNA barcodes, the nucleotide sequence of a short DNA fragment. NMR can provide direct NMR fingerprint determination (complete assignment of the signals by 1D and 2D experiments), quantitative NMR and chemometric analysis (the metabolite fingerprint is based on the distribution of intensity in the NMR spectrum to provide sample classification). NIR spectroscopy is a fast qualitative and quantitative analytical method, getting knowledge about plant species and/or its geographic origin. Finally, the development of chemical and biological sensors is currently one of the most active areas of analytical research. Immobilization of specific enzymes led to recognize definite class of compounds such as cysteine sulfoxides, glucosinolates, cyanogenic glycosides, and polyphenols. Other recognition elements are nucleic acids to evaluate the ability of different molecules to bind DNA. Sensors have also been developed for the detection of heavy metals in botanicals. Moreover, the analysis of mycotoxins and pesticides, could represent another field of possible application. These alternative/complementary analytical methods represent tools which appear to be an analyst's dream: they are able to give rapid analysis responses; to operate directly on complex matrices, in many cases; to be selective and sensitive enough for the required application; to be portable and sometimes also disposable; and to have fast analysis times. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  16. Metal-amplified Density Assays, (MADAs), including a Density-Linked Immunosorbent Assay (DeLISA).

    PubMed

    Subramaniam, Anand Bala; Gonidec, Mathieu; Shapiro, Nathan D; Kresse, Kayleigh M; Whitesides, George M

    2015-02-21

    This paper reports the development of Metal-amplified Density Assays, or MADAs - a method of conducting quantitative or multiplexed assays, including immunoassays, by using Magnetic Levitation (MagLev) to measure metal-amplified changes in the density of beads labeled with biomolecules. The binding of target analytes (i.e. proteins, antibodies, antigens) to complementary ligands immobilized on the surface of the beads, followed by a chemical amplification of the binding in a form that results in a change in the density of the beads (achieved by using gold nanoparticle-labeled biomolecules, and electroless deposition of gold or silver), translates analyte binding events into changes in density measureable using MagLev. A minimal model based on diffusion-limited growth of hemispherical nuclei on a surface reproduces the dynamics of the assay. A MADA - when performed with antigens and antibodies - is called a Density-Linked Immunosorbent Assay, or DeLISA. Two immunoassays provided a proof of principle: a competitive quantification of the concentration of neomycin in whole milk, and a multiplexed detection of antibodies against Hepatitis C virus NS3 protein and syphilis T. pallidum p47 protein in serum. MADAs, including DeLISAs, require, besides the requisite biomolecules and amplification reagents, minimal specialized equipment (two permanent magnets, a ruler or a capillary with calibrated length markings) and no electrical power to obtain a quantitative readout of analyte concentration. With further development, the method may be useful in resource-limited or point-of-care settings.

  17. Probability of identification: a statistical model for the validation of qualitative botanical identification methods.

    PubMed

    LaBudde, Robert A; Harnly, James M

    2012-01-01

    A qualitative botanical identification method (BIM) is an analytical procedure that returns a binary result (1 = Identified, 0 = Not Identified). A BIM may be used by a buyer, manufacturer, or regulator to determine whether a botanical material being tested is the same as the target (desired) material, or whether it contains excessive nontarget (undesirable) material. The report describes the development and validation of studies for a BIM based on the proportion of replicates identified, or probability of identification (POI), as the basic observed statistic. The statistical procedures proposed for data analysis follow closely those of the probability of detection, and harmonize the statistical concepts and parameters between quantitative and qualitative method validation. Use of POI statistics also harmonizes statistical concepts for botanical, microbiological, toxin, and other analyte identification methods that produce binary results. The POI statistical model provides a tool for graphical representation of response curves for qualitative methods, reporting of descriptive statistics, and application of performance requirements. Single collaborator and multicollaborative study examples are given.

  18. Detection of medically important Candida species by absolute quantitation real-time polymerase chain reaction.

    PubMed

    Than, Leslie Thian Lung; Chong, Pei Pei; Ng, Kee Peng; Seow, Heng Fong

    2015-01-01

    The number of invasive candidiasis cases has risen especially with an increase in the number of immunosuppressed and immunocom promised patients. The early detection of Candida species which is specific and sensitive is important in determining the correct administration of antifungal drugs to patients. This study aims to develop a method for the detection, identification and quantitation of medically important Candida species through quantitative polymerase chain reaction (qPCR). The isocitrate lyase (ICL) gene which is not found in mammals was chosen as the target gene of real-time PCR. Absolute quantitation of the gene copy number was achieved by constructing the plasmid containing the ICL gene which is used to generate standard curve. Twenty fungal species, two bacterial species and human DNA were tested to check the specificity of the detection method. All eight Candida species were successfully detected, identified and quantitated based on the ICL gene. A seven-log range of the gene copy number and a minimum detection limit of 10(3) copies were achieved. A one-tube absolute quantification real-time PCR that differentiates medically important Candida species via individual unique melting temperature was achieved. Analytical sensitivity and specificity were not compromised.

  19. Fast analytical scatter estimation using graphics processing units.

    PubMed

    Ingleby, Harry; Lippuner, Jonas; Rickey, Daniel W; Li, Yue; Elbakri, Idris

    2015-01-01

    To develop a fast patient-specific analytical estimator of first-order Compton and Rayleigh scatter in cone-beam computed tomography, implemented using graphics processing units. The authors developed an analytical estimator for first-order Compton and Rayleigh scatter in a cone-beam computed tomography geometry. The estimator was coded using NVIDIA's CUDA environment for execution on an NVIDIA graphics processing unit. Performance of the analytical estimator was validated by comparison with high-count Monte Carlo simulations for two different numerical phantoms. Monoenergetic analytical simulations were compared with monoenergetic and polyenergetic Monte Carlo simulations. Analytical and Monte Carlo scatter estimates were compared both qualitatively, from visual inspection of images and profiles, and quantitatively, using a scaled root-mean-square difference metric. Reconstruction of simulated cone-beam projection data of an anthropomorphic breast phantom illustrated the potential of this method as a component of a scatter correction algorithm. The monoenergetic analytical and Monte Carlo scatter estimates showed very good agreement. The monoenergetic analytical estimates showed good agreement for Compton single scatter and reasonable agreement for Rayleigh single scatter when compared with polyenergetic Monte Carlo estimates. For a voxelized phantom with dimensions 128 × 128 × 128 voxels and a detector with 256 × 256 pixels, the analytical estimator required 669 seconds for a single projection, using a single NVIDIA 9800 GX2 video card. Accounting for first order scatter in cone-beam image reconstruction improves the contrast to noise ratio of the reconstructed images. The analytical scatter estimator, implemented using graphics processing units, provides rapid and accurate estimates of single scatter and with further acceleration and a method to account for multiple scatter may be useful for practical scatter correction schemes.

  20. Simultaneous quantitation of five Panax notoginseng saponins by multi heart-cutting two-dimensional liquid chromatography: Method development and application to the quality control of eight Notoginseng containing Chinese patent medicines.

    PubMed

    Yao, Chang-liang; Yang, Wen-zhi; Wu, Wan-Yyng; Da, Juan; Hou, Jin-jun; Zhang, Jing-xian; Zhang, Yan-hai; Jin, Yan; Yang, Min; Jiang, Bao-hong; Liu, Xuan; Guo, De-an

    2015-07-10

    Current China Pharmacopoeia (ChP) standards employ diversified and case-dependent assay methods to evaluate the quality of different Chinese patent medicines (CPMs) that contain Panax notoginseng as the monarch drug. These conventional, HPLC-based approaches, utilizing a complex sample preparation procedure, can easily result in low analytical efficiency and possible component loss. Here, a "monomethod-heterotrait matrix" (MHM) strategy is proposed, that is, developing a universal multi heart-cutting two-dimensional liquid chromatography (MHC-2D-LC) approach that facilitates the simultaneous quantitation of five P. notoginseng saponins (noto-R1, Re, Rg1, Rb1, and Rd) in eight different CPMs. The MHC-2D-LC system was constructed on a dual-gradient liquid chromatography instrument equipped with a Poroshell SB C18 column and a Zorbax SB-Aq column for respective (1)D and (2)D separation. Method validation was performed in terms of specificity, linearity (r(2) and F-test), intra-/inter-day precision (0.4-7.9%), stability (1.2-3.9%), and recovery (90.2-108.7%), and the LODs and LOQs (loaded masses) of the five analytes varied between 4.0-11.0ng and 6.0-33.0ng, respectively. The validated MHC-2D-LC approach was subsequently applied to quantify the five saponins in thirty batches of different CPMs. The method demonstrated superiority over the current ChP assay methods in respect of specificity (avoiding co-elution), resolution (Rs>1.5), sample preparation (easy-to-implement ultrasonic extraction without repeated re-extraction), and transfer rate (minimum component loss). This is the first application of an MHC-2D-LC method for the quantitative assessment of the constituents of CPMs. The MHM approach represents a new, strategically significant methodology for the quality control of CPMs that involve complex chemical matrix. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Simultaneous Determination of Oxysterols, Cholesterol and 25-Hydroxy-Vitamin D3 in Human Plasma by LC-UV-MS

    PubMed Central

    Narayanaswamy, Rohini; Iyer, Vignesh; Khare, Prachi; Bodziak, Mary Lou; Badgett, Darlene; Zivadinov, Robert; Weinstock-Guttman, Bianca; Rideout, Todd C.; Ramanathan, Murali; Browne, Richard W.

    2015-01-01

    Background Oxysterols are promising biomarkers of neurodegenerative diseases that are linked with cholesterol and vitamin D metabolism. There is an unmet need for methods capable of sensitive, and simultaneous quantitation of multiple oxysterols, vitamin D and cholesterol pathway biomarkers. Methods A method for simultaneous determination of 5 major oxysterols, 25-hydroxy vitamin D3 and cholesterol in human plasma was developed. Total oxysterols were prepared by room temperature saponification followed by solid phase extraction from plasma spiked with deuterated internal standards. Oxysterols were resolved by reverse phase HPLC using a methanol/water/0.1% formic acid gradient. Oxysterols and 25-hydroxy vitamin D3 were detected with atmospheric pressure chemical ionization mass spectrometry in positive ion mode; in-series photodiode array detection at 204nm was used for cholesterol. Method validation studies were performed. Oxysterol levels in 220 plasma samples from healthy control subjects, multiple sclerosis and other neurological disorders patients were quantitated. Results Our method quantitated 5 oxysterols, cholesterol and 25-hydroxy vitamin D3 from 200 μL plasma in 35 minutes. Recoveries were >85% for all analytes and internal standards. The limits of detection were 3-10 ng/mL for oxysterols and 25-hydroxy vitamin D3 and 1 μg/mL for simultaneous detection of cholesterol. Analytical imprecision was <10 %CV for 24(S)-, 25-, 27-, 7α-hydroxycholesterol (HC) and cholesterol and ≤15 % for 7-keto-cholesterol. Multiple Sclerosis and other neurological disorder patients had lower 27-hydroxycholesterol levels compared to controls whereas 7α-hydroxycholesterol was lower specifically in Multiple Sclerosis. Conclusion The method is suitable for measuring plasma oxysterols levels in human health and disease. Analysis of human plasma indicates that the oxysterol, bile acid precursors 7α-hydroxycholesterol and 27-hydroxycholesterol are lower in Multiple Sclerosis and may serve as potential biomarkers of disease. PMID:25875771

  2. Concentration of organic compounds in natural waters with solid-phase dispersion based on advesicle modified silica prior to liquid chromatography.

    PubMed

    Parisis, Nikolaos A; Giokas, Dimosthenis L; Vlessidis, Athanasios G; Evmiridis, Nicholaos P

    2005-12-02

    The ability of vesicle-coated silica to aid the extraction of organic compounds from water prior to liquid chromatographic analysis is presented for the first time. The method is based on the formation of silica supported cationic multi-lamellar vesicles of gemini surfactants inherently ensuring the presence of hydrophilic and hydrophobic sites for the partitioning of analytes bearing different properties. Method development is illustrated by studying the adsolubilization of UV absorbing chemicals from swimming pool water. Due to the requirement for external energy input (intense shearing) a method based on solid-phase dispersion (SPD) was applied producing better results than off-line solid-phase extraction (SPE). Meticulous investigation of the experimental parameters was conducted in order to elucidate the mechanisms behind the proposed extraction pattern. Analyte recoveries were quantitative under the optimum experimental conditions offering recoveries higher than 96% with RSD values below 5%.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alexeev, A. V.; Maltseva, D. V.; Ivanov, V. A., E-mail: ivanov@polly.phys.msu.ru

    We study force-extension curves of a single semiflexible chain consisting of several rigid rods connected by flexible spacers. The atomic force microscopy and laser optical or magnetic tweezers apparatus stretching these rod-coil macromolecules are discussed. In addition, the stretching by external isotropic force is analyzed. The main attention is focused on computer simulation and analytical results. We demonstrate that the force-extension curves for rod-coil chains composed of two or three rods of equal length differ not only quantitatively but also qualitatively in different probe methods. These curves have an anomalous shape for a chain of two rods. End-to-end distributions ofmore » rod-coil chains are calculated by Monte Carlo method and compared with analytical equations. The influence of the spacer’s length on the force-extension curves in different probe methods is analyzed. The results can be useful for interpreting experiments on the stretching of rod-coil block-copolymers.« less

  4. Isolation of purified oocyst walls and sporocysts from Toxoplasma gondii.

    PubMed

    Everson, William V; Ware, Michael W; Dubey, J P; Lindquist, H D Alan

    2002-01-01

    Toxoplasma gondii oocysts are environmentally resistant and can infect virtually all warm-blooded hosts, including humans and livestock. Little is known about the biochemical basis for this resistance of oocysts, and mechanism for excystation of T. gondii sporozoites. The objective of the present study was to evaluate different methods (mechanical fragmentation, gradients, flow cytometry) to separate and purify T. gondii oocyst walls and sporocysts. Oocyst walls were successfully separated and purified using iodixanol gradients. Sporocysts were successfully separated and purified using iodixanol and Percoll gradients. Purification was also achieved by flow cytometry. Flow cytometry with fluorescence-activated cell sorting (FACS) yielded analytical quantities of oocyst walls and intact sporocysts. Flow cytometry with FACS also proved useful for quantitation of purity obtained following iodixanol gradient fractionation. Methods reported in this paper will be useful for analytical purposes, such as proteomic analysis of components unique to this life cycle stage, development of detection methods, or excystation studies.

  5. Designing Studies That Would Address the Multilayered Nature of Health Care

    PubMed Central

    Pennell, Michael; Rhoda, Dale; Hade, Erinn M.; Paskett, Electra D.

    2010-01-01

    We review design and analytic methods available for multilevel interventions in cancer research with particular attention to study design, sample size requirements, and potential to provide statistical evidence for causal inference. The most appropriate methods will depend on the stage of development of the research and whether randomization is possible. Early on, fractional factorial designs may be used to screen intervention components, particularly when randomization of individuals is possible. Quasi-experimental designs, including time-series and multiple baseline designs, can be useful once the intervention is designed because they require few sites and can provide the preliminary evidence to plan efficacy studies. In efficacy and effectiveness studies, group-randomized trials are preferred when randomization is possible and regression discontinuity designs are preferred otherwise if assignment based on a quantitative score is possible. Quasi-experimental designs may be used, especially when combined with recent developments in analytic methods to reduce bias in effect estimates. PMID:20386057

  6. Research on the analytical method about influence of gas leakage and explosion on subway

    NASA Astrophysics Data System (ADS)

    Ji, Wendong; Yang, Ligong; Chen, Lin

    2018-05-01

    With the construction and development of city subway, the cross impact of underground rail transit and gas pipe network is becoming more and more serious, but there is no analytical method for the impact of gas explosions on the subway. According to this paper, the gas leakage is equivalent to the TNT explosion equivalent, based on which, the calculation of the explosive impact load is carried out. On the basis of the concrete manifestation of gas explosion, it is more convenient to carry out the subsequent calculation by equivalently treating the explosive impact load as a uniform load within a certain range. The overlying soil of the subway station has played a protective role for the subway, making the displacement of the subway structure in the explosion process significantly reduced. The analysis on the actual case shows that this method can be successfully applied to the quantitative analysis of such accidents.

  7. Development of a low-cost method of analysis for the qualitative and quantitative analysis of butyltins in environmental samples.

    PubMed

    Bangkedphol, Sornnarin; Keenan, Helen E; Davidson, Christine; Sakultantimetha, Arthit; Songsasen, Apisit

    2008-12-01

    Most analytical methods for butyltins are based on high resolution techniques with complicated sample preparation. For this study, a simple application of an analytical method was developed using High Performance Liquid Chromatography (HPLC) with UV detection. The developed method was studied to determine tributyltin (TBT), dibutyltin (DBT) and monobutyltin (MBT) in sediment and water samples. The separation was performed in isocratic mode on an ultra cyanopropyl column with a mobile phase of hexane containing 5% THF and 0.03% acetic acid. This method was confirmed using standard GC/MS techniques and verified by statistical paired t-test method. Under the experimental conditions used, the limit of detection (LOD) of TBT and DBT were 0.70 and 0.50 microg/mL, respectively. The optimised extraction method for butyltins in water and sediment samples involved using hexane containing 0.05-0.5% tropolone and 0.2% sodium chloride in water at pH 1.7. The quantitative extraction of butyltin compounds in a certified reference material (BCR-646) and naturally contaminated samples was achieved with recoveries ranging from 95 to 108% and at %RSD 0.02-1.00%. This HPLC method and optimum extraction conditions were used to determine the contamination level of butyltins in environmental samples collected from the Forth and Clyde canal, Scotland, UK. The values obtained severely exceeded the Environmental Quality Standard (EQS) values. Although high resolution methods are utilised extensively for this type of research, the developed method is cheaper in both terms of equipment and running costs, faster in analysis time and has comparable detection limits to the alternative methods. This is advantageous not just as a confirmatory technique but also to enable further research in this field.

  8. Validated reversed phase LC method for quantitative analysis of polymethoxyflavones in citrus peel extracts.

    PubMed

    Wang, Zhenyu; Li, Shiming; Ferguson, Stephen; Goodnow, Robert; Ho, Chi-Tang

    2008-01-01

    Polymethoxyflavones (PMFs), which exist exclusively in the citrus genus, have biological activities including anti-inflammatory, anticarcinogenic, and antiatherogenic properties. A validated RPLC method was developed for quantitative analysis of six major PMFs, namely nobiletin, tangeretin, sinensetin, 5,6,7,4'-tetramethoxyflavone, 3,5,6,7,3',4'-hexamethoxyflavone, and 3,5,6,7,8,3',4'-heptamethoxyflavone. The polar embedded LC stationary phase was able to fully resolve the six analogues. The developed method was fully validated in terms of linearity, accuracy, precision, sensitivity, and system suitability. The LOD of the method was calculated as 0.15 microg/mL and the recovery rate was between 97.0 and 105.1%. This analytical method was successfully applied to quantify the individual PMFs in four commercially available citrus peel extracts (CPEs). Each extract shows significant difference in the PMF composition and concentration. This method may provide a simple, rapid, and reliable tool to help reveal the correlation between the bioactivity of the PMF extracts and the individual PMF content.

  9. Screening of groundwater remedial alternatives for brownfield sites: a comprehensive method integrated MCDA with numerical simulation.

    PubMed

    Li, Wei; Zhang, Min; Wang, Mingyu; Han, Zhantao; Liu, Jiankai; Chen, Zhezhou; Liu, Bo; Yan, Yan; Liu, Zhu

    2018-06-01

    Brownfield sites pollution and remediation is an urgent environmental issue worldwide. The screening and assessment of remedial alternatives is especially complex owing to its multiple criteria that involves technique, economy, and policy. To help the decision-makers selecting the remedial alternatives efficiently, the criteria framework conducted by the U.S. EPA is improved and a comprehensive method that integrates multiple criteria decision analysis (MCDA) with numerical simulation is conducted in this paper. The criteria framework is modified and classified into three categories: qualitative, semi-quantitative, and quantitative criteria, MCDA method, AHP-PROMETHEE (analytical hierarchy process-preference ranking organization method for enrichment evaluation) is used to determine the priority ranking of the remedial alternatives and the solute transport simulation is conducted to assess the remedial efficiency. A case study was present to demonstrate the screening method in a brownfield site in Cangzhou, northern China. The results show that the systematic method provides a reliable way to quantify the priority of the remedial alternatives.

  10. A fluorescence anisotropy method for measuring protein concentration in complex cell culture media.

    PubMed

    Groza, Radu Constantin; Calvet, Amandine; Ryder, Alan G

    2014-04-22

    The rapid, quantitative analysis of the complex cell culture media used in biopharmaceutical manufacturing is of critical importance. Requirements for cell culture media composition profiling, or changes in specific analyte concentrations (e.g. amino acids in the media or product protein in the bioprocess broth) often necessitate the use of complicated analytical methods and extensive sample handling. Rapid spectroscopic methods like multi-dimensional fluorescence (MDF) spectroscopy have been successfully applied for the routine determination of compositional changes in cell culture media and bioprocess broths. Quantifying macromolecules in cell culture media is a specific challenge as there is a need to implement measurements rapidly on the prepared media. However, the use of standard fluorescence spectroscopy is complicated by the emission overlap from many media components. Here, we demonstrate how combining anisotropy measurements with standard total synchronous fluorescence spectroscopy (TSFS) provides a rapid, accurate quantitation method for cell culture media. Anisotropy provides emission resolution between large and small fluorophores while TSFS provides a robust measurement space. Model cell culture media was prepared using yeastolate (2.5 mg mL(-1)) spiked with bovine serum albumin (0 to 5 mg mL(-1)). Using this method, protein emission is clearly discriminated from background yeastolate emission, allowing for accurate bovine serum albumin (BSA) quantification over a 0.1 to 4.0 mg mL(-1) range with a limit of detection (LOD) of 13.8 μg mL(-1). Copyright © 2014. Published by Elsevier B.V.

  11. Fast and selective pressurized liquid extraction with simultaneous in cell clean up for the analysis of alkylphenols and bisphenol A in bivalve molluscs.

    PubMed

    Salgueiro-González, N; Turnes-Carou, I; Muniategui-Lorenzoa, S; López-Mahía, P; Prada-Rodríguez, D

    2012-12-28

    A novel and green analytical methodology for the determination of alkylphenols (4-tert-octylphenol, 4-n-octylphenol, 4-n-nonylphenol, nonylphenol technical mixture) and bisphenol A in bivalve mollusc samples was developed and validated. The method was based on selective pressurized liquid extraction (SPLE) with a simultaneous in cell clean up combined with liquid chromatography–electrospray ionization tandem mass spectrometry in negative mode (LC–ESI-MS/MS). Quantitation was performed by standard addition curves in order to correct matrix effects. The analytical features of the method were satisfactory: relative recoveries varied between 80 and 107% and repeatability and intermediate precision were <20% for all compounds. Uncertainty assessment of measurement was estimated on the basis of an in-house validation according to EURACHEM/CITAC guide. Quantitation limits of the method (MQL) ranged between 0.34 (4-n-octylphenol) and 3.6 ng g(−1) dry weight (nonylphenol). The main advantages of the method are sensitivity, selectivity, automaticity, low volumes of solvents required and low sample analysis time (according with the principles of Green Chemistry). The method was applied to the analysis of mussel samples of Galicia coast (NW of Spain). Nonylphenol and 4-tert-octylphenol were measured in all samples at concentrations between 9.3 and 372 ng g(−1) dw. As an approach, the human daily intake of these compounds was estimated and no risk for human health was found.

  12. Quantitative Determination of Fluorine Content in Blends of Polylactide (PLA)–Talc Using Near Infrared Spectroscopy

    PubMed Central

    Tamburini, Elena; Tagliati, Chiara; Bonato, Tiziano; Costa, Stefania; Scapoli, Chiara; Pedrini, Paola

    2016-01-01

    Near-infrared spectroscopy (NIRS) has been widely used for quantitative and/or qualitative determination of a wide range of matrices. The objective of this study was to develop a NIRS method for the quantitative determination of fluorine content in polylactide (PLA)-talc blends. A blending profile was obtained by mixing different amounts of PLA granules and talc powder. The calibration model was built correlating wet chemical data (alkali digestion method) and NIR spectra. Using FT (Fourier Transform)-NIR technique, a Partial Least Squares (PLS) regression model was set-up, in a concentration interval of 0 ppm of pure PLA to 800 ppm of pure talc. Fluorine content prediction (R2cal = 0.9498; standard error of calibration, SEC = 34.77; standard error of cross-validation, SECV = 46.94) was then externally validated by means of a further 15 independent samples (R2EX.V = 0.8955; root mean standard error of prediction, RMSEP = 61.08). A positive relationship between an inorganic component as fluorine and NIR signal has been evidenced, and used to obtain quantitative analytical information from the spectra. PMID:27490548

  13. Quantitation of repaglinide and metabolites in mouse whole-body thin tissue sections using droplet-based liquid microjunction surface sampling-high-performance liquid chromatography-electrospray ionization tandem mass spectrometry.

    PubMed

    Chen, Weiqi; Wang, Lifei; Van Berkel, Gary J; Kertesz, Vilmos; Gan, Jinping

    2016-03-25

    Herein, quantitation aspects of a fully automated autosampler/HPLC-MS/MS system applied for unattended droplet-based surface sampling of repaglinide dosed thin tissue sections with subsequent HPLC separation and mass spectrometric analysis of parent drug and various drug metabolites were studied. Major organs (brain, lung, liver, kidney and muscle) from whole-body thin tissue sections and corresponding organ homogenates prepared from repaglinide dosed mice were sampled by surface sampling and by bulk extraction, respectively, and analyzed by HPLC-MS/MS. A semi-quantitative agreement between data obtained by surface sampling and that by employing organ homogenate extraction was observed. Drug concentrations obtained by the two methods followed the same patterns for post-dose time points (0.25, 0.5, 1 and 2 h). Drug amounts determined in the specific tissues was typically higher when analyzing extracts from the organ homogenates. In addition, relative comparison of the levels of individual metabolites between the two analytical methods also revealed good semi-quantitative agreement. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Quantitation of repaglinide and metabolites in mouse whole-body thin tissue sections using droplet-based liquid microjunction surface sampling-high-performance liquid chromatography-electrospray ionization tandem mass spectrometry

    DOE PAGES

    Chen, Weiqi; Wang, Lifei; Van Berkel, Gary J.; ...

    2015-11-03

    Herein, quantitation aspects of a fully automated autosampler/HPLC-MS/MS system applied for unattended droplet-based surface sampling of repaglinide dosed thin tissue sections with subsequent HPLC separation and mass spectrometric analysis of parent drug and various drug metabolites was studied. Major organs (brain, lung, liver, kidney, muscle) from whole-body thin tissue sections and corresponding organ homogenates prepared from repaglinide dosed mice were sampled by surface sampling and by bulk extraction, respectively, and analyzed by HPLC-MS/MS. A semi-quantitative agreement between data obtained by surface sampling and that by employing organ homogenate extraction was observed. Drug concentrations obtained by the two methods followed themore » same patterns for post-dose time points (0.25, 0.5, 1 and 2 h). Drug amounts determined in the specific tissues was typically higher when analyzing extracts from the organ homogenates. Furthermore, relative comparison of the levels of individual metabolites between the two analytical methods also revealed good semi-quantitative agreement.« less

  15. Quantitation of repaglinide and metabolites in mouse whole-body thin tissue sections using droplet-based liquid microjunction surface sampling-high-performance liquid chromatography-electrospray ionization tandem mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Weiqi; Wang, Lifei; Van Berkel, Gary J.

    Herein, quantitation aspects of a fully automated autosampler/HPLC-MS/MS system applied for unattended droplet-based surface sampling of repaglinide dosed thin tissue sections with subsequent HPLC separation and mass spectrometric analysis of parent drug and various drug metabolites was studied. Major organs (brain, lung, liver, kidney, muscle) from whole-body thin tissue sections and corresponding organ homogenates prepared from repaglinide dosed mice were sampled by surface sampling and by bulk extraction, respectively, and analyzed by HPLC-MS/MS. A semi-quantitative agreement between data obtained by surface sampling and that by employing organ homogenate extraction was observed. Drug concentrations obtained by the two methods followed themore » same patterns for post-dose time points (0.25, 0.5, 1 and 2 h). Drug amounts determined in the specific tissues was typically higher when analyzing extracts from the organ homogenates. Furthermore, relative comparison of the levels of individual metabolites between the two analytical methods also revealed good semi-quantitative agreement.« less

  16. State of the art in bile analysis in forensic toxicology.

    PubMed

    Bévalot, F; Cartiser, N; Bottinelli, C; Guitton, J; Fanton, L

    2016-02-01

    In forensic toxicology, alternative matrices to blood are useful in case of limited, unavailable or unusable blood sample, suspected postmortem redistribution or long drug intake-to-sampling interval. The present article provides an update on the state of knowledge for the use of bile in forensic toxicology, through a review of the Medline literature from 1970 to May 2015. Bile physiology and technical aspects of analysis (sampling, storage, sample preparation and analytical methods) are reported, to highlight specificities and consequences from an analytical and interpretative point of view. A table summarizes cause of death and quantification in bile and blood of 133 compounds from more than 200 case reports, providing a useful tool for forensic physicians and toxicologists involved in interpreting bile analysis. Qualitative and quantitative interpretation is discussed. As bile/blood concentration ratios are high for numerous molecules or metabolites, bile is a matrix of choice for screening when blood concentrations are low or non-detectable: e.g., cases of weak exposure or long intake-to-death interval. Quantitative applications have been little investigated, but small molecules with low bile/blood concentration ratios seem to be good candidates for quantitative bile-based interpretation. Further experimental data on the mechanism and properties of biliary extraction of xenobiotics of forensic interest are required to improve quantitative interpretation. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  17. Quantitative analysis of glycerophospholipids by LC-MS: acquisition, data handling, and interpretation

    PubMed Central

    Myers, David S.; Ivanova, Pavlina T.; Milne, Stephen B.; Brown, H. Alex

    2012-01-01

    As technology expands what it is possible to accurately measure, so too the challenges faced by modern mass spectrometry applications expand. A high level of accuracy in lipid quantitation across thousands of chemical species simultaneously is demanded. While relative changes in lipid amounts with varying conditions may provide initial insights or point to novel targets, there are many questions that require determination of lipid analyte absolute quantitation. Glycerophospholipids present a significant challenge in this regard, given the headgroup diversity, large number of possible acyl chain combinations, and vast range of ionization efficiency of species. Lipidomic output is being used more often not just for profiling of the masses of species, but also for highly-targeted flux-based measurements which put additional burdens on the quantitation pipeline. These first two challenges bring into sharp focus the need for a robust lipidomics workflow including deisotoping, differentiation from background noise, use of multiple internal standards per lipid class, and the use of a scriptable environment in order to create maximum user flexibility and maintain metadata on the parameters of the data analysis as it occurs. As lipidomics technology develops and delivers more output on a larger number of analytes, so must the sophistication of statistical post-processing also continue to advance. High-dimensional data analysis methods involving clustering, lipid pathway analysis, and false discovery rate limitation are becoming standard practices in a maturing field. PMID:21683157

  18. Simple and Robust N-Glycan Analysis Based on Improved 2-Aminobenzoic Acid Labeling for Recombinant Therapeutic Glycoproteins.

    PubMed

    Jeong, Yeong Ran; Kim, Sun Young; Park, Young Sam; Lee, Gyun Min

    2018-03-21

    N-glycans of therapeutic glycoproteins are critical quality attributes that should be monitored throughout all stages of biopharmaceutical development. To reduce both the time for sample preparation and the variations in analytical results, we have developed an N-glycan analysis method that includes improved 2-aminobenzoic acid (2-AA) labeling to easily remove deglycosylated proteins. Using this analytical method, 15 major 2-AA-labeled N-glycans of Enbrel ® were separated into single peaks in hydrophilic interaction chromatography mode and therefore could be quantitated. 2-AA-labeled N-glycans were also highly compatible with in-line quadrupole time-of-flight mass spectrometry (MS) for structural identification. The structures of 15 major and 18 minor N-glycans were identified from their mass values determined by quadrupole time-of-flight MS. Furthermore, the structures of 14 major N-glycans were confirmed by interpreting the MS/MS data of each N-glycan. This analytical method was also successfully applied to neutral N-glycans of Humira ® and highly sialylated N-glycans of NESP ® . Furthermore, the analysis data of Enbrel ® that were accumulated for 2.5 years demonstrated the high-level consistency of this analytical method. Taken together, the results show that a wide repertoire of N-glycans of therapeutic glycoproteins can be analyzed with high efficiency and consistency using the improved 2-AA labeling-based N-glycan analysis method. Copyright © 2018 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  19. VALIDATION OF ANALYTICAL METHODS AND INSTRUMENTATION FOR BERYLLIUM MEASUREMENT: REVIEW AND SUMMARY OF AVAILABLE GUIDES, PROCEDURES, AND PROTOCOLS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ekechukwu, A

    Method validation is the process of evaluating whether an analytical method is acceptable for its intended purpose. For pharmaceutical methods, guidelines from the United States Pharmacopeia (USP), International Conference on Harmonisation (ICH), and the United States Food and Drug Administration (USFDA) provide a framework for performing such valications. In general, methods for regulatory compliance must include studies on specificity, linearity, accuracy, precision, range, detection limit, quantitation limit, and robustness. Elements of these guidelines are readily adapted to the issue of validation for beryllium sampling and analysis. This document provides a listing of available sources which can be used to validatemore » analytical methods and/or instrumentation for beryllium determination. A literature review was conducted of available standard methods and publications used for method validation and/or quality control. A comprehensive listing of the articles, papers and books reviewed is given in the Appendix. Available validation documents and guides are listed therein; each has a brief description of application and use. In the referenced sources, there are varying approches to validation and varying descriptions of the valication process at different stages in method development. This discussion focuses on valication and verification of fully developed methods and instrumentation that have been offered up for use or approval by other laboratories or official consensus bodies such as ASTM International, the International Standards Organization (ISO) and the Association of Official Analytical Chemists (AOAC). This review was conducted as part of a collaborative effort to investigate and improve the state of validation for measuring beryllium in the workplace and the environment. Documents and publications from the United States and Europe are included. Unless otherwise specified, all referenced documents were published in English.« less

  20. Real-Time Quantitative Analysis of Valproic Acid in Exhaled Breath by Low Temperature Plasma Ionization Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Gong, Xiaoxia; Shi, Songyue; Gamez, Gerardo

    2017-04-01

    Real-time analysis of exhaled human breath is a rapidly growing field in analytical science and has great potential for rapid and noninvasive clinical diagnosis and drug monitoring. In the present study, an LTP-MS method was developed for real-time, in-vivo and quantitative analysis of γ-valprolactone, a metabolite of valproic acid (VPA), in exhaled breath without any sample pretreatment. In particular, the effect of working conditions and geometry of the LTP source on the ions of interest, protonated molecular ion at m/z 143 and ammonium adduct ion at m/z 160, were systematically characterized. Tandem mass spectrometry (MS/MS) with collision-induced dissociation (CID) was carried out in order to identify γ-valprolactone molecular ions ( m/z 143), and the key fragment ion ( m/z 97) was used for quantitation. In addition, the fragmentation of ammonium adduct ions to protonated molecular ions was performed in-source to improve the signal-to-noise ratio. At optimum conditions, signal reproducibility with an RSD of 8% was achieved. The concentration of γ-valprolactone in exhaled breath was determined for the first time to be 4.83 (±0.32) ng/L by using standard addition method. Also, a calibration curve was obtained with a linear range from 0.7 to 22.5 ng/L, and the limit of detection was 0.18 ng/L for γ-valprolactone in standard gas samples. Our results show that LTP-MS is a powerful analytical platform with high sensitivity for quantitative analysis of volatile organic compounds in human breath, and can have potential applications in pharmacokinetics or for patient monitoring and treatment.

  1. High-throughput, label-free, single-cell, microalgal lipid screening by machine-learning-equipped optofluidic time-stretch quantitative phase microscopy.

    PubMed

    Guo, Baoshan; Lei, Cheng; Kobayashi, Hirofumi; Ito, Takuro; Yalikun, Yaxiaer; Jiang, Yiyue; Tanaka, Yo; Ozeki, Yasuyuki; Goda, Keisuke

    2017-05-01

    The development of reliable, sustainable, and economical sources of alternative fuels to petroleum is required to tackle the global energy crisis. One such alternative is microalgal biofuel, which is expected to play a key role in reducing the detrimental effects of global warming as microalgae absorb atmospheric CO 2 via photosynthesis. Unfortunately, conventional analytical methods only provide population-averaged lipid amounts and fail to characterize a diverse population of microalgal cells with single-cell resolution in a non-invasive and interference-free manner. Here high-throughput label-free single-cell screening of lipid-producing microalgal cells with optofluidic time-stretch quantitative phase microscopy was demonstrated. In particular, Euglena gracilis, an attractive microalgal species that produces wax esters (suitable for biodiesel and aviation fuel after refinement), within lipid droplets was investigated. The optofluidic time-stretch quantitative phase microscope is based on an integration of a hydrodynamic-focusing microfluidic chip, an optical time-stretch quantitative phase microscope, and a digital image processor equipped with machine learning. As a result, it provides both the opacity and phase maps of every single cell at a high throughput of 10,000 cells/s, enabling accurate cell classification without the need for fluorescent staining. Specifically, the dataset was used to characterize heterogeneous populations of E. gracilis cells under two different culture conditions (nitrogen-sufficient and nitrogen-deficient) and achieve the cell classification with an error rate of only 2.15%. The method holds promise as an effective analytical tool for microalgae-based biofuel production. © 2017 International Society for Advancement of Cytometry. © 2017 International Society for Advancement of Cytometry.

  2. Spectrochemical analysis of powdered biological samples using transversely excited atmospheric carbon dioxide laser plasma excitation

    NASA Astrophysics Data System (ADS)

    Zivkovic, Sanja; Momcilovic, Milos; Staicu, Angela; Mutic, Jelena; Trtica, Milan; Savovic, Jelena

    2017-02-01

    The aim of this study was to develop a simple laser induced breakdown spectroscopy (LIBS) method for quantitative elemental analysis of powdered biological materials based on laboratory prepared calibration samples. The analysis was done using ungated single pulse LIBS in ambient air at atmospheric pressure. Transversely-Excited Atmospheric pressure (TEA) CO2 laser was used as an energy source for plasma generation on samples. The material used for the analysis was a blue-green alga Spirulina, widely used in food and pharmaceutical industries and also in a few biotechnological applications. To demonstrate the analytical potential of this particular LIBS system the obtained spectra were compared to the spectra obtained using a commercial LIBS system based on pulsed Nd:YAG laser. A single sample of known concentration was used to estimate detection limits for Ba, Ca, Fe, Mg, Mn, Si and Sr and compare detection power of these two LIBS systems. TEA CO2 laser based LIBS was also applied for quantitative analysis of the elements in powder Spirulina samples. Analytical curves for Ba, Fe, Mg, Mn and Sr were constructed using laboratory produced matrix-matched calibration samples. Inductively coupled plasma optical emission spectroscopy (ICP-OES) was used as the reference technique for elemental quantification, and reasonably well agreement between ICP and LIBS data was obtained. Results confirm that, in respect to its sensitivity and precision, TEA CO2 laser based LIBS can be successfully applied for quantitative analysis of macro and micro-elements in algal samples. The fact that nearly all classes of materials can be prepared as powders implies that the proposed method could be easily extended to a quantitative analysis of different kinds of materials, organic, biological or inorganic.

  3. A Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) Quantitative Analysis Method Based on the Auto-Selection of an Internal Reference Line and Optimized Estimation of Plasma Temperature.

    PubMed

    Yang, Jianhong; Li, Xiaomeng; Xu, Jinwu; Ma, Xianghong

    2018-01-01

    The quantitative analysis accuracy of calibration-free laser-induced breakdown spectroscopy (CF-LIBS) is severely affected by the self-absorption effect and estimation of plasma temperature. Herein, a CF-LIBS quantitative analysis method based on the auto-selection of internal reference line and the optimized estimation of plasma temperature is proposed. The internal reference line of each species is automatically selected from analytical lines by a programmable procedure through easily accessible parameters. Furthermore, the self-absorption effect of the internal reference line is considered during the correction procedure. To improve the analysis accuracy of CF-LIBS, the particle swarm optimization (PSO) algorithm is introduced to estimate the plasma temperature based on the calculation results from the Boltzmann plot. Thereafter, the species concentrations of a sample can be calculated according to the classical CF-LIBS method. A total of 15 certified alloy steel standard samples of known compositions and elemental weight percentages were used in the experiment. Using the proposed method, the average relative errors of Cr, Ni, and Fe calculated concentrations were 4.40%, 6.81%, and 2.29%, respectively. The quantitative results demonstrated an improvement compared with the classical CF-LIBS method and the promising potential of in situ and real-time application.

  4. Big data to smart data in Alzheimer's disease: The brain health modeling initiative to foster actionable knowledge.

    PubMed

    Geerts, Hugo; Dacks, Penny A; Devanarayan, Viswanath; Haas, Magali; Khachaturian, Zaven S; Gordon, Mark Forrest; Maudsley, Stuart; Romero, Klaus; Stephenson, Diane

    2016-09-01

    Massive investment and technological advances in the collection of extensive and longitudinal information on thousands of Alzheimer patients results in large amounts of data. These "big-data" databases can potentially advance CNS research and drug development. However, although necessary, they are not sufficient, and we posit that they must be matched with analytical methods that go beyond retrospective data-driven associations with various clinical phenotypes. Although these empirically derived associations can generate novel and useful hypotheses, they need to be organically integrated in a quantitative understanding of the pathology that can be actionable for drug discovery and development. We argue that mechanism-based modeling and simulation approaches, where existing domain knowledge is formally integrated using complexity science and quantitative systems pharmacology can be combined with data-driven analytics to generate predictive actionable knowledge for drug discovery programs, target validation, and optimization of clinical development. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  5. Volatile substance abuse--post-mortem diagnosis.

    PubMed

    Wille, Sarah M R; Lambert, Willy E E

    2004-06-10

    A substantial number of children and adolescents world-wide abuse volatile substances with the intention to experience an euphoric state of consciousness. Although the ratio of deaths to nonfatal inhalation escapades is low, it is an important and preventable cause of death in young people. In the analytical investigation of volatile substances proper sample collection, storage and handling are important in view of the volatile nature of the compounds. Volatile organic compounds in post-mortem matrices such as blood, urine and tissues are generally determined by gas chromatography after extracting the compounds with methods such as static and dynamic headspace or even with pulse-heating and solvent extraction. In post-mortem cases, metabolites in urine seem less relevant, however, trichloroethanol and trichloroacetic acid were determined in several cases. When interpreting qualitative and quantitative results, researchers should be aware of false conclusions. The main reason why scepticism is necessary is the occurrence of losses of analytes during sampling, sample handling and storage, which results in false quantitation.

  6. Mass-transfer limitations for immobilized enzyme-catalyzed kinetic resolution of racemate in a fixed-bed reactor.

    PubMed

    Xiu, G H; Jiang, L; Li, P

    2001-07-05

    A mathematical model has been developed for immobilized enzyme-catalyzed kinetic resolution of racemate in a fixed-bed reactor in which the enzyme-catalyzed reaction (the irreversible uni-uni competitive Michaelis-Menten kinetics is chosen as an example) was coupled with intraparticle diffusion, external mass transfer, and axial dispersion. The effects of mass-transfer limitations, competitive inhibition of substrates, deactivation on the enzyme effective enantioselectivity, and the optical purity and yield of the desired product are examined quantitatively over a wide range of parameters using the orthogonal collocation method. For a first-order reaction, an analytical solution is derived from the mathematical model for slab-, cylindrical-, and spherical-enzyme supports. Based on the analytical solution for the steady-state resolution process, a new concise formulation is presented to predict quantitatively the mass-transfer limitations on enzyme effective enantioselectivity and optical purity and yield of the desired product for a continuous steady-state kinetic resolution process in a fixed-bed reactor. Copyright 2001 John Wiley & Sons, Inc.

  7. Toxicologic evaluation of analytes from Tank 241-C-103

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mahlum, D.D.; Young, J.Y.; Weller, R.E.

    1994-11-01

    Westinghouse Hanford Company requested PNL to assemble a toxicology review panel (TRP) to evaluate analytical data compiled by WHC, and provide advice concerning potential health effects associated with exposure to tank-vapor constituents. The team`s objectives would be to (1) review procedures used for sampling vapors from tanks, (2) identify constituents in tank-vapor samples that could be related to symptoms reported by workers, (3) evaluate the toxicological implications of those constituents by comparison to establish toxicological databases, (4) provide advice for additional analytical efforts, and (5) support other activities as requested by WHC. The TRP represents a wide range of expertise,more » including toxicology, industrial hygiene, and occupational medicine. The TRP prepared a list of target analytes that chemists at the Oregon Graduate Institute/Sandia (OGI), Oak Ridge National Laboratory (ORNL), and PNL used to establish validated methods for quantitative analysis of head-space vapors from Tank 241-C-103. this list was used by the analytical laboratories to develop appropriate analytical methods for samples from Tank 241-C-103. Target compounds on the list included acetone, acetonitrile, ammonia, benzene, 1, 3-butadiene, butanal, n-butanol, hexane, 2-hexanone, methylene chloride, nitric oxide, nitrogen dioxide, nitrous oxide, dodecane, tridecane, propane nitrile, sulfur oxide, tributyl phosphate, and vinylidene chloride. The TRP considered constituent concentrations, current exposure limits, reliability of data relative to toxicity, consistency of the analytical data, and whether the material was carcinogenic or teratogenic. A final consideration in the analyte selection process was to include representative chemicals for each class of compounds found.« less

  8. Molecular counting of membrane receptor subunits with single-molecule localization microscopy

    NASA Astrophysics Data System (ADS)

    Krüger, Carmen; Fricke, Franziska; Karathanasis, Christos; Dietz, Marina S.; Malkusch, Sebastian; Hummer, Gerhard; Heilemann, Mike

    2017-02-01

    We report on quantitative single-molecule localization microscopy, a method that next to super-resolved images of cellular structures provides information on protein copy numbers in protein clusters. This approach is based on the analysis of blinking cycles of single fluorophores, and on a model-free description of the distribution of the number of blinking events. We describe the experimental and analytical procedures, present cellular data of plasma membrane proteins and discuss the applicability of this method.

  9. Hydrolysis Studies and Quantitative Determination of Aluminum Ions Using [superscript 27]Al NMR: An Undergraduate Analytical Chemistry Experiment

    ERIC Educational Resources Information Center

    Curtin, Maria A.; Ingalls, Laura R.; Campbell, Andrew; James-Pederson, Magdalena

    2008-01-01

    This article describes a novel experiment focused on metal ion hydrolysis and the equilibria related to metal ions in aqueous systems. Using [superscript 27]Al NMR, the students become familiar with NMR spectroscopy as a quantitative analytical tool for the determination of aluminum by preparing a standard calibration curve using standard aluminum…

  10. Can NMR solve some significant challenges in metabolomics?

    PubMed Central

    Gowda, G.A. Nagana; Raftery, Daniel

    2015-01-01

    The field of metabolomics continues to witness rapid growth driven by fundamental studies, methods development, and applications in a number of disciplines that include biomedical science, plant and nutrition sciences, drug development, energy and environmental sciences, toxicology, etc. NMR spectroscopy is one of the two most widely used analytical platforms in the metabolomics field, along with mass spectrometry (MS). NMR's excellent reproducibility and quantitative accuracy, its ability to identify structures of unknown metabolites, its capacity to generate metabolite profiles using intact biospecimens with no need for separation, and its capabilities for tracing metabolic pathways using isotope labeled substrates offer unique strengths for metabolomics applications. However, NMR's limited sensitivity and resolution continue to pose a major challenge and have restricted both the number and the quantitative accuracy of metabolites analyzed by NMR. Further, the analysis of highly complex biological samples has increased the demand for new methods with improved detection, better unknown identification, and more accurate quantitation of larger numbers of metabolites. Recent efforts have contributed significant improvements in these areas, and have thereby enhanced the pool of routinely quantifiable metabolites. Additionally, efforts focused on combining NMR and MS promise opportunities to exploit the combined strength of the two analytical platforms for direct comparison of the metabolite data, unknown identification and reliable biomarker discovery that continue to challenge the metabolomics field. This article presents our perspectives on the emerging trends in NMR-based metabolomics and NMR's continuing role in the field with an emphasis on recent and ongoing research from our laboratory. PMID:26476597

  11. Electron-Beam Diagnostic Methods for Hypersonic Flow Diagnostics

    NASA Technical Reports Server (NTRS)

    1994-01-01

    The purpose of this work was the evaluation of the use of electron-bean fluorescence for flow measurements during hypersonic flight. Both analytical and numerical models were developed in this investigation to evaluate quantitatively flow field imaging concepts based upon the electron beam fluorescence technique for use in flight research and wind tunnel applications. Specific models were developed for: (1) fluorescence excitation/emission for nitrogen, (2) rotational fluorescence spectrum for nitrogen, (3) single and multiple scattering of electrons in a variable density medium, (4) spatial and spectral distribution of fluorescence, (5) measurement of rotational temperature and density, (6) optical filter design for fluorescence imaging, and (7) temperature accuracy and signal acquisition time requirements. Application of these models to a typical hypersonic wind tunnel flow is presented. In particular, the capability of simulating the fluorescence resulting from electron impact ionization in a variable density nitrogen or air flow provides the capability to evaluate the design of imaging instruments for flow field mapping. The result of this analysis is a recommendation that quantitative measurements of hypersonic flow fields using electron-bean fluorescence is a tractable method with electron beam energies of 100 keV. With lower electron energies, electron scattering increases with significant beam divergence which makes quantitative imaging difficult. The potential application of the analytical and numerical models developed in this work is in the design of a flow field imaging instrument for use in hypersonic wind tunnels or onboard a flight research vehicle.

  12. Development and validation of a LC-MS/MS assay for quantitation of plasma citrulline for application to animal models of the acute radiation syndrome across multiple species.

    PubMed

    Jones, Jace W; Tudor, Gregory; Bennett, Alexander; Farese, Ann M; Moroni, Maria; Booth, Catherine; MacVittie, Thomas J; Kane, Maureen A

    2014-07-01

    The potential risk of a radiological catastrophe highlights the need for identifying and validating potential biomarkers that accurately predict radiation-induced organ damage. A key target organ that is acutely sensitive to the effects of irradiation is the gastrointestinal (GI) tract, referred to as the GI acute radiation syndrome (GI-ARS). Recently, citrulline has been identified as a potential circulating biomarker for radiation-induced GI damage. Prior to biologically validating citrulline as a biomarker for radiation-induced GI injury, there is the important task of developing and validating a quantitation assay for citrulline detection within the radiation animal models used for biomarker validation. Herein, we describe the analytical development and validation of citrulline detection using a liquid chromatography tandem mass spectrometry assay that incorporates stable-label isotope internal standards. Analytical validation for specificity, linearity, lower limit of quantitation, accuracy, intra- and interday precision, extraction recovery, matrix effects, and stability was performed under sample collection and storage conditions according to the Guidance for Industry, Bioanalytical Methods Validation issued by the US Food and Drug Administration. In addition, the method was biologically validated using plasma from well-characterized mouse, minipig, and nonhuman primate GI-ARS models. The results demonstrated that circulating citrulline can be confidently quantified from plasma. Additionally, circulating citrulline displayed a time-dependent response for radiological doses covering GI-ARS across multiple species.

  13. Detection of nucleophosmin 1 mutations by quantitative real-time polymerase chain reaction versus capillary electrophoresis: a comparative study.

    PubMed

    Barakat, Fareed H; Luthra, Rajyalakshmi; Yin, C Cameron; Barkoh, Bedia A; Hai, Seema; Jamil, Waqar; Bhakta, Yaminiben I; Chen, Su; Medeiros, L Jeffrey; Zuo, Zhuang

    2011-08-01

    Nucleophosmin 1 (NPM1) is the most commonly mutated gene in acute myeloid leukemia. Detection of NPM1 mutations is useful for stratifying patients for therapy, predicting prognosis, and assessing for minimal residual disease. Several methods have been developed to rapidly detect NPM1 mutations in genomic DNA and/or messenger RNA specimens. To directly compare a quantitative real-time polymerase chain reaction (qPCR) assay with a widely used capillary electrophoresis assay for detecting NPM1 mutations. We adopted and modified a qPCR assay designed to detect the 6 most common NPM1 mutations and performed the assay in parallel with capillary electrophoresis assay in 207 bone marrow aspirate or peripheral blood samples from patients with a range of hematolymphoid neoplasms. The qPCR assay demonstrated a higher analytical sensitivity than the capillary electrophoresis 1/1000 versus 1/40, respectively. The capillary electrophoresis assay generated 10 equivocal results that needed to be repeated, whereas the qPCR assay generated only 1 equivocal result. After test conditions were optimized, the qPCR and capillary electrophoresis methods produced 100% concordant results, 85 positive and 122 negative. Given the higher analytical sensitivity and specificity of the qPCR assay, that assay is less likely to generate equivocal results than the capillary electrophoresis assay. Moreover, the qPCR assay is quantitative, faster, cheaper, less prone to contamination, and well suited for monitoring minimal residual disease.

  14. Can NMR solve some significant challenges in metabolomics?

    NASA Astrophysics Data System (ADS)

    Nagana Gowda, G. A.; Raftery, Daniel

    2015-11-01

    The field of metabolomics continues to witness rapid growth driven by fundamental studies, methods development, and applications in a number of disciplines that include biomedical science, plant and nutrition sciences, drug development, energy and environmental sciences, toxicology, etc. NMR spectroscopy is one of the two most widely used analytical platforms in the metabolomics field, along with mass spectrometry (MS). NMR's excellent reproducibility and quantitative accuracy, its ability to identify structures of unknown metabolites, its capacity to generate metabolite profiles using intact bio-specimens with no need for separation, and its capabilities for tracing metabolic pathways using isotope labeled substrates offer unique strengths for metabolomics applications. However, NMR's limited sensitivity and resolution continue to pose a major challenge and have restricted both the number and the quantitative accuracy of metabolites analyzed by NMR. Further, the analysis of highly complex biological samples has increased the demand for new methods with improved detection, better unknown identification, and more accurate quantitation of larger numbers of metabolites. Recent efforts have contributed significant improvements in these areas, and have thereby enhanced the pool of routinely quantifiable metabolites. Additionally, efforts focused on combining NMR and MS promise opportunities to exploit the combined strength of the two analytical platforms for direct comparison of the metabolite data, unknown identification and reliable biomarker discovery that continue to challenge the metabolomics field. This article presents our perspectives on the emerging trends in NMR-based metabolomics and NMR's continuing role in the field with an emphasis on recent and ongoing research from our laboratory.

  15. Determination of non-certified levoglucosan, sugar polyols and ergosterol in NIST Standard Reference Material 1649a

    NASA Astrophysics Data System (ADS)

    Pomata, Donatella; Di Filippo, Patrizia; Riccardi, Carmela; Buiarelli, Francesca; Gallo, Valentina

    2014-02-01

    Organic component of airborne particulate matter originates from both natural and anthropogenic sources whose contributions can be identified through the analysis of chemical markers. The validation of analytical methods for analysis of compounds used as chemical markers is of great importance especially if they must be determined in rather complex matrices. Currently, standard reference materials (SRM) with certified values for all those analytes are not available. In this paper, we report a method for the simultaneous determination of levoglucosan and xylitol as tracers for biomass burning emissions, and arabitol, mannitol and ergosterol as biomarkers for airborne fungi in SRM 1649a, by GC/MS. Their quantitative analysis in SRM 1649a was carried out using both internal standard calibration curves and standard addition method. A matrix effect was observed for all analytes, minor for levoglucosan and major for polyols and ergosterol. The results related to levoglucosan around 160 μg g-1 agreed with those reported by other authors, while no comparison was possible for xylitol (120 μg g-1), arabitol (15 μg g-1), mannitol (18 μg g-1), and ergosterol (0.5 μg g-1). The analytical method used for SRM 1649a was also applied to PM10 samples collected in Rome during four seasonal sampling campaigns. The ratios between annual analyte concentrations in PM10 samples and in SRM 1649a were of the same order of magnitude although particulate matter samples analyzed were collected in two different sites and periods.

  16. Methods for detection of GMOs in food and feed.

    PubMed

    Marmiroli, Nelson; Maestri, Elena; Gullì, Mariolina; Malcevschi, Alessio; Peano, Clelia; Bordoni, Roberta; De Bellis, Gianluca

    2008-10-01

    This paper reviews aspects relevant to detection and quantification of genetically modified (GM) material within the feed/food chain. The GM crop regulatory framework at the international level is evaluated with reference to traceability and labelling. Current analytical methods for the detection, identification, and quantification of transgenic DNA in food and feed are reviewed. These methods include quantitative real-time PCR, multiplex PCR, and multiplex real-time PCR. Particular attention is paid to methods able to identify multiple GM events in a single reaction and to the development of microdevices and microsensors, though they have not been fully validated for application.

  17. [Quantitative surface analysis of Pt-Co, Cu-Au and Cu-Ag alloy films by XPS and AES].

    PubMed

    Li, Lian-Zhong; Zhuo, Shang-Jun; Shen, Ru-Xiang; Qian, Rong; Gao, Jie

    2013-11-01

    In order to improve the quantitative analysis accuracy of AES, We associated XPS with AES and studied the method to reduce the error of AES quantitative analysis, selected Pt-Co, Cu-Au and Cu-Ag binary alloy thin-films as the samples, used XPS to correct AES quantitative analysis results by changing the auger sensitivity factors to make their quantitative analysis results more similar. Then we verified the accuracy of the quantitative analysis of AES when using the revised sensitivity factors by other samples with different composition ratio, and the results showed that the corrected relative sensitivity factors can reduce the error in quantitative analysis of AES to less than 10%. Peak defining is difficult in the form of the integral spectrum of AES analysis since choosing the starting point and ending point when determining the characteristic auger peak intensity area with great uncertainty, and to make analysis easier, we also processed data in the form of the differential spectrum, made quantitative analysis on the basis of peak to peak height instead of peak area, corrected the relative sensitivity factors, and verified the accuracy of quantitative analysis by the other samples with different composition ratio. The result showed that the analytical error in quantitative analysis of AES reduced to less than 9%. It showed that the accuracy of AES quantitative analysis can be highly improved by the way of associating XPS with AES to correct the auger sensitivity factors since the matrix effects are taken into account. Good consistency was presented, proving the feasibility of this method.

  18. Towards a full integration of optimization and validation phases: An analytical-quality-by-design approach.

    PubMed

    Hubert, C; Houari, S; Rozet, E; Lebrun, P; Hubert, Ph

    2015-05-22

    When using an analytical method, defining an analytical target profile (ATP) focused on quantitative performance represents a key input, and this will drive the method development process. In this context, two case studies were selected in order to demonstrate the potential of a quality-by-design (QbD) strategy when applied to two specific phases of the method lifecycle: the pre-validation study and the validation step. The first case study focused on the improvement of a liquid chromatography (LC) coupled to mass spectrometry (MS) stability-indicating method by the means of the QbD concept. The design of experiments (DoE) conducted during the optimization step (i.e. determination of the qualitative design space (DS)) was performed a posteriori. Additional experiments were performed in order to simultaneously conduct the pre-validation study to assist in defining the DoE to be conducted during the formal validation step. This predicted protocol was compared to the one used during the formal validation. A second case study based on the LC/MS-MS determination of glucosamine and galactosamine in human plasma was considered in order to illustrate an innovative strategy allowing the QbD methodology to be incorporated during the validation phase. An operational space, defined by the qualitative DS, was considered during the validation process rather than a specific set of working conditions as conventionally performed. Results of all the validation parameters conventionally studied were compared to those obtained with this innovative approach for glucosamine and galactosamine. Using this strategy, qualitative and quantitative information were obtained. Consequently, an analyst using this approach would be able to select with great confidence several working conditions within the operational space rather than a given condition for the routine use of the method. This innovative strategy combines both a learning process and a thorough assessment of the risk involved. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Analysis of hydroxamate siderophores in soil solution using liquid chromatography with mass spectrometry and tandem mass spectrometry with on-line sample preconcentration.

    PubMed

    Olofsson, Madelen A; Bylund, Dan

    2015-10-01

    A liquid chromatography with electrospray ionization mass spectrometry method was developed to quantitatively and qualitatively analyze 13 hydroxamate siderophores (ferrichrome, ferrirubin, ferrirhodin, ferrichrysin, ferricrocin, ferrioxamine B, D1 , E and G, neocoprogen I and II, coprogen and triacetylfusarinine C). Samples were preconcentrated on-line by a switch-valve setup prior to analyte separation on a Kinetex C18 column. Gradient elution was performed using a mixture of an ammonium formate buffer and acetonitrile. Total analysis time including column conditioning was 20.5 min. Analytes were fragmented by applying collision-induced dissociation, enabling structural identification by tandem mass spectrometry. Limit of detection values for the selected ion monitoring method ranged from 71 pM to 1.5 nM with corresponding values of two to nine times higher for the multiple reaction monitoring method. The liquid chromatography with mass spectrometry method resulted in a robust and sensitive quantification of hydroxamate siderophores as indicated by retention time stability, linearity, sensitivity, precision and recovery. The analytical error of the methods, assessed through random-order, duplicate analysis of soil samples extracted with a mixture of 10 mM phosphate buffer and methanol, appears negligible in relation to between-sample variations. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Analytical validation of quantitative immunohistochemical assays of tumor infiltrating lymphocyte biomarkers.

    PubMed

    Singh, U; Cui, Y; Dimaano, N; Mehta, S; Pruitt, S K; Yearley, J; Laterza, O F; Juco, J W; Dogdas, B

    2018-06-04

    Tumor infiltrating lymphocytes (TIL), especially T-cells, have both prognostic and therapeutic applications. The presence of CD8+ effector T-cells and the ratio of CD8+ cells to FOXP3+ regulatory T-cells have been used as biomarkers of disease prognosis to predict response to various immunotherapies. Blocking the interaction between inhibitory receptors on T-cells and their ligands with therapeutic antibodies including atezolizumab, nivolumab, pembrolizumab and tremelimumab increases the immune response against cancer cells and has shown significant improvement in clinical benefits and survival in several different tumor types. The improved clinical outcome is presumed to be associated with a higher tumor infiltration; therefore, it is thought that more accurate methods for measuring the amount of TIL could assist prognosis and predict treatment response. We have developed and validated quantitative immunohistochemistry (IHC) assays for CD3, CD8 and FOXP3 for immunophenotyping T-lymphocytes in tumor tissue. Various types of formalin fixed, paraffin embedded (FFPE) tumor tissues were immunolabeled with anti-CD3, anti-CD8 and anti-FOXP3 antibodies using an IHC autostainer. The tumor area of stained tissues, including the invasive margin of the tumor, was scored by a pathologist (visual scoring) and by computer-based quantitative image analysis. Two image analysis scores were obtained for the staining of each biomarker: the percent positive cells in the tumor area and positive cells/mm 2 tumor area. Comparison of visual vs. image analysis scoring methods using regression analysis showed high correlation and indicated that quantitative image analysis can be used to score the number of positive cells in IHC stained slides. To demonstrate that the IHC assays produce consistent results in normal daily testing, we evaluated the specificity, sensitivity and reproducibility of the IHC assays using both visual and image analysis scoring methods. We found that CD3, CD8 and FOXP3 IHC assays met the fit-for-purpose analytical acceptance validation criteria and that they can be used to support clinical studies.

Top