Sample records for quantitative autoradiographic measurement

  1. Autoradiographic method for quantitation of deposition and distribution of radiocalcium in bone

    PubMed Central

    Lawrence Riggs, B; Bassingthwaighte, James B.; Jowsey, Jenifer; Peter Pequegnat, E

    2010-01-01

    A method is described for quantitating autoradiographs of bone-seeking isotopes in microscopic sections of bone. Autoradiographs of bone sections containing 45Ca and internal calibration standards are automatically scanned with a microdensitometer. The digitized optical density output is stored on magnetic tape and is converted by computer to equivalent activity of 45Ca per gram of bone. The computer determines the total 45Ca uptake in the bone section and, on the basis of optical density and anatomic position, quantitatively divides the uptake into 4 components, each representing a separate physiologic process (bone formation, secondary mineralization, diffuse long-term exchange, and surface short-term exchange). The method is also applicable for quantitative analysis of microradiographs of bone sections for mineral content and density. PMID:5416906

  2. Data analysis software for the autoradiographic enhancement process. Volumes 1, 2, and 3, and appendix

    NASA Technical Reports Server (NTRS)

    Singh, S. P.

    1979-01-01

    The computer software developed to set up a method for Wiener spectrum analysis of photographic films is presented. This method is used for the quantitative analysis of the autoradiographic enhancement process. The software requirements and design for the autoradiographic enhancement process are given along with the program listings and the users manual. A software description and program listings modification of the data analysis software are included.

  3. An autoradiographic analysis of cholinergic receptors in mouse brain after chronic nicotine treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pauly, J.R.; Marks, M.J.; Gross, S.D.

    1991-09-01

    Quantitative autoradiographic procedures were used to examine the effects of chronic nicotine infusion on the number of central nervous system nicotinic cholinergic receptors. Female DBA mice were implanted with jugular cannulas and infused with saline or various doses of nicotine (0.25, 0.5, 1.0 or 2.0 mg/kg/hr) for 10 days. The animals were then sacrificed and the brains were removed and frozen in isopentane. Cryostat sections were collected and prepared for autoradiographic procedures as previously described. Nicotinic cholinergic receptors were labeled with L-(3H)nicotine or alpha-(125I)bungarotoxin; (3H)quinuclidinyl benzilate was used to measure muscarinic cholinergic receptor binding. Chronic nicotine infusion increased the numbermore » of sites labeled by (3H)nicotine in most brain areas. However, the extent of the increase in binding as well as the dose-response curves for the increase were widely different among brain regions. After the highest treatment dose, binding was increased in 67 of 86 regions measured. Septal and thalamic regions were most resistant to change. Nicotinic binding measured by alpha-(125I)bungarotoxin also increased after chronic treatment, but in a less robust fashion. At the highest treatment dose, only 26 of 80 regions were significantly changes. Muscarinic binding was not altered after chronic nicotine treatment. These data suggest that brain regions are not equivalent in the mechanisms that regulate alterations in nicotinic cholinergic receptor binding after chronic nicotine treatment.« less

  4. Autoradiographic detection of diphtheria toxin resistant mutants in human diploid fibroblasts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gupta, R.S.; Singh, B.

    1985-01-01

    An autoradiographic procedure for the detection of diphtheria toxin (DT) resistant (Dip/sub R/) mutants in human diploid fibroblast (HDF) cells has been developed. The assay is based on the observation that when HDFs from confluent cultures are seeded in medium containing 0.01 flocculating units/ml or higher concentration of DT, protein synthesis in sensitive cells is severely inhibited by 4-6 hr. If at this or later time, a radiolabeled protein precursor (eg, /sup 3/H-leucine) is added to the culture, it is almost exclusively incorporated into the resistant cells, which are then readily identified by autoradiography. These studies provide strong evidence thatmore » the labeled cells identified by autoradiography are bona fide Dip/sub R/ mutants. The detection of Dip/sub R/ cells by autoradiography is apparently not affected by the presence of the sensitive cells in the mixtures. The spontaneous frequency of Dip/sub R/ cells in HDFs has been found to be in the range of 1-5 x 10/sup -6/, and this increases in a dose dependent manner upon treatment with the mutagen ethyl methanesulfonate. These results indicate that the autoradiographic assay could be used for quantitative mutagenesis. Since the autoradiographic assay does not depend on cell division, it may prove useful in estimating the incidence of pre-existing mutations in cell populations that either do not divide or have very limited growth potential (eg, lymphocytes, muscle cells, neurons, senescent fibroblasts, etc.).« less

  5. Automated image analysis of alpha-particle autoradiographs of human bone

    NASA Astrophysics Data System (ADS)

    Hatzialekou, Urania; Henshaw, Denis L.; Fews, A. Peter

    1988-01-01

    Further techniques [4,5] for the analysis of CR-39 α-particle autoradiographs have been developed for application to α-autoradiography of autopsy bone at natural levels for exposure. The most significant new approach is the use of fully automated image analysis using a system developed in this laboratory. A 5 cm × 5 cm autoradiograph of tissue in which the activity is below 1 Bq kg -1 is scanned to both locate and measure the recorded α-particle tracks at a rate of 5 cm 2/h. Improved methods of calibration have also been developed. The techniques are described and in order to illustrate their application, a bone sample contaminated with 239Pu is analysed. Results from natural levels are the subject of a separate publication.

  6. Quantitative autoradiographic analysis of muscarinic receptor subtypes and their role in representational memory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Messer, W.S.

    1986-01-01

    Autoradiographic techniques were used to examine the distribution of muscarinic receptors in rat brain slices. Agonist and selective antagonist binding were examined by measuring the ability for unlabeled ligands to inhibit (/sup 3/H)-1-QNB labeling of muscarinic receptors. The distribution of high affinity pirenzepine binding sites (M/sub 1/ subtype) was distinct from the distribution of high affinity carbamylcholine sites, which corresponded to the M/sub 2/ subtype. In a separate assay, the binding profile for pirenzepine was shown to differ from the profile for scopolamine, a classical muscarinic antagonist. Muscarinic antagonists, when injected into the Hippocampus, impaired performance of a representational memorymore » task. Pirenzepine, the M/sub 1/ selective antagonist, produced representational memory deficits. Scopolamine, a less selective muscarinic antagonist, caused increases in running times in some animals which prevented a definitive interpretation of the nature of the impairment. Pirenzepine displayed a higher affinity for the hippocampus and was more effective in producing a selective impairment of representational memory than scopolamine. The data indicated that cholinergic activity in the hippocampus was necessary for representation memory function.« less

  7. In vitro autoradiographic localization of angiotensin-converting enzyme in sarcoid lymph nodes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allen, R.K.; Chai, S.Y.; Dunbar, M.S.

    1986-09-01

    Angiotensin-converting enzyme (ACE) was localized in sarcoid lymph nodes by an in vitro autoradiographic technique using a synthetic ACE inhibitor of high affinity, /sup 125/I-labelled 351A. The lymph nodes were from seven patients with active sarcoidosis who underwent mediastinoscopy and from six control subjects who had nodes resected at either mediastinoscopy or laparotomy. Angiotensin-converting enzyme was localized in the epithelioid cells of sarcoid granulomata in markedly increased amounts compared with control nodes, where it was restricted to vessels and some histiocytes. In sarcoid lymph nodes, there was little ACE present in lymphocytes or fibrous tissue. Sarcoid nodes with considerable fibrosismore » had much less intense ACE activity than the nonfibrotic nodes. The specific activity of ACE measured by an enzymatic assay in both the control and sarcoid lymph nodes closely reflected the ACE activity demonstrated by autoradiography. Sarcoid lymph nodes with fibrosis had an ACE specific activity of half that of nonfibrotic nodes (p less than 0.05). There was a 15-fold increase in specific ACE activity in sarcoid nodes (p less than 0.05) compared to normal. Serum ACE was significantly higher in those sarcoid patients whose lymph nodes were not fibrosed compared with those with fibrosis (p less than 0.01). This technique offers many advantages over the use of polyclonal antibodies. The 351A is a highly specific ACE inhibitor, chemically defined and in limitless supply. This method enables the quantitation of results, and autoradiographs may be stored indefinitely for later comparison.« less

  8. Experiment K-7-18: Effects of Spaceflight in the Muscle Adductor Longus of Rats Flown in the Soviet Biosatellite Cosmos 2044. Part 2; Quantitative Autoradiographic Analysis of Gaba (Benzodiazepine) and Muscarinic (Cholinergic) Receptors in the Forebrain of Rats Flown on Cosmos 2044

    NASA Technical Reports Server (NTRS)

    Wu, L.; Daunton, N. G.; Krasnov, I. B.; DAmelio, F.; Hyde, T. M.; Sigworth, S. K.

    1994-01-01

    Quantitative autoradiographic analysis of receptors for GABA and acetylcholine in the forebrain of rats flown on COSMOS 2044 was undertaken as part of a joint US-Soviet study to determine the effects of microgravity on the central nervous system, and in particular on the sensory and motor portions of the forebrain. Changes in binding of these receptors in tissue from animals exposed to microgravity would provide evidence for possible changes in neural processing as a result of exposure to microgravity. Tritium-labelled diazepam and Quinuclidinyl-benzilate (QNB) were used to visualize GABA (benzodiazepine) and muscarinic (cholinergic) receptors, respectively. The density of tritium-labelled radioligands bound to various regions in the forebrain of both flight and control animals were measured from autoradiograms. Data from rats flown in space and from ground-based control animals that were not exposed to microgravity were compared.

  9. Autoradiographic demonstration of oxytocin-binding sites in the macula densa

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stoeckel, M.E.; Freund-Mercier, M.J.

    1989-08-01

    Specific oxytocin (OT)-binding sites were localized in the rat kidney with use of a selective {sup 125}I-labeled OT antagonist ({sup 125}I-OTA). High concentrations of OT binding sites were detected on the juxtaglomerular apparatus with use of the conventional film autoradiographic technique. No labeling occurred on other renal structures. The cellular localization of the OT binding sites within the juxtaglomerular apparatus was studied in light microscope autoradiography, on semithin sections from paraformaldehyde-fixed kidney slices incubated in the presence of {sup 125}I-OTA. These preparations revealed selective labeling of the macula densa, mainly concentrated at the basal pole of the cells. Control experimentsmore » showed first that {sup 125}I-OTA binding characteristics were not noticeably altered by prior paraformaldehyde fixation of the kidneys and second that autoradiographic detection of the binding sites was not impaired by histological treatments following binding procedures. In view of the role of the macula densa in the tubuloglomerular feedback, the putative OT receptors of this structure might mediate the stimulatory effect of OT on glomerular filtration.« less

  10. Autoradiographic labeling of the cholinergic habenulo-interpeduncular projection.

    PubMed

    Villani, L; Contestabile, A; Fonnum, F

    1983-12-11

    The transmitter-specific autoradiographic method has been used to retrogradely trace the habenulo-interpeduncular cholinergic projection. [3H]Choline injection in the interpeduncular nucleus resulted in remarkable labeling of the fasciculus retroflexus and in very strong accumulation of silver grains in the medial habenula. Brainstem nuclei sending non-cholinergic projections to the interpeduncular nucleus were not labeled. The present findings strongly support the notion of a cholinergic medial habenula-interpeduncular nucleus projection in agreement with recent immunohistochemical evidence, but in contrast to previous immunocytochemical and pharmacohistochemical results.

  11. QUANTITATIVE PLUTONIUM MICRODISTRIBUTION IN BONE TISSUE OF VERTEBRA FROM A MAYAK WORKER

    PubMed Central

    Lyovkina, Yekaterina V.; Miller, Scott C.; Romanov, Sergey A.; Krahenbuhl, Melinda P.; Belosokhov, Maxim V.

    2010-01-01

    The purpose was to obtain quantitative data on plutonium microdistribution in different structural elements of human bone tissue for local dose assessment and dosimetric models validation. A sample of the thoracic vertebra was obtained from a former Mayak worker with a rather high plutonium burden. Additional information was obtained on occupational and exposure history, medical history, and measured plutonium content in organs. Plutonium was detected in bone sections from its fission tracks in polycarbonate film using neutron-induced autoradiography. Quantitative analysis of randomly selected microscopic fields on one of the autoradiographs was performed. Data included fission fragment tracks in different bone tissue and surface areas. Quantitative information on plutonium microdistribution in human bone tissue was obtained for the first time. From these data, quantitative relationship of plutonium decays in bone volume to decays on bone surface in cortical and trabecular fractions were defined as 2.0 and 0.4, correspondingly. The measured quantitative relationship of decays in bone volume to decays on bone surface does not coincide with recommended models for the cortical bone fraction by the International Commission on Radiological Protection. Biokinetic model parameters of extrapulmonary compartments might need to be adjusted after expansion of the data set on quantitative plutonium microdistribution in other bone types in human as well as other cases with different exposure patterns and types of plutonium. PMID:20838087

  12. Autoradiographic localization of beta-adrenoceptors in asthmatic human lung

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spina, D.; Rigby, P.J.; Paterson, J.W.

    1989-11-01

    The autoradiographic distribution and density of beta-adrenoceptors in human non-diseased and asthmatic bronchi were investigated using (125I)iodocyanopindolol (I-CYP). Analysis of the effects of the beta-adrenoceptor antagonists on I-CYP binding demonstrated that betaxolol (20 nM, beta 1-selective) had no significant effect on specific grain density in either nonasthmatic or asthmatic human bronchus, whereas ICI-118551 (20 nM, beta 2-selective) inhibited I-CYP binding by 85 +/- 9% and 89 +/- 3%, respectively. Thus, homogeneous populations of beta 2-adrenoceptors existed in bronchi from both sources. Large populations of beta-adrenoceptors were localized to the bronchial epithelium, submucosal glands, and airway smooth muscle. Asthmatic bronchial tissuemore » featured epithelial damage with exfoliated cells associated with luminal mucus plugs. A thickened basement membrane and airway smooth muscle hyperplasia were also evident. High levels of specific I-CYP binding were also detected over asthmatic bronchial smooth muscle, as assessed by autoradiography and quantitation of specific grain densities. Isoproterenol and fenoterol were 10- and 13-fold less potent, respectively, in bronchi from asthmatic lung than in those from nonasthmatic lung. However, this attenuated responsiveness to beta-adrenoceptor agonists was not caused by reduced beta-adrenoceptor density in asthmatic airways. A defect may exist in the coupling between beta-adrenoceptors and postreceptor mechanisms in severely asthmatic lung.« less

  13. Interlaboratory comparison of autoradiographic DNA profiling measurements: precision and concordance.

    PubMed

    Duewer, D L; Lalonde, S A; Aubin, R A; Fourney, R M; Reeder, D J

    1998-05-01

    Knowledge of the expected uncertainty in restriction fragment length polymorphism (RFLP) measurements is required for confident exchange of such data among different laboratories. The total measurement uncertainty among all Technical Working Group for DNA Analysis Methods laboratories has previously been characterized and found to be acceptably small. Casework cell line control measurements provided by six Royal Canadian Mounted Police (RCMP) and 30 U.S. commercial, local, state, and Federal forensic laboratories enable quantitative determination of the within-laboratory precision and among-laboratory concordance components of measurement uncertainty typical of both sets of laboratories. Measurement precision is the same in the two countries for DNA fragments of size 1000 base pairs (bp) to 10,000 bp. However, the measurement concordance among the RCMP laboratories is clearly superior to that within the U.S. forensic community. This result is attributable to the use of a single analytical protocol in all RCMP laboratories. Concordance among U.S. laboratories cannot be improved through simple mathematical adjustments. Community-wide efforts focused on improved concordance may be the most efficient mechanism for further reduction of among-laboratory RFLP measurement uncertainty, should the resources required to fully evaluate potential cross-jurisdictional matches become burdensome as the number of RFLP profiles on record increases.

  14. Density and distribution of hippocampal neurotransmitter receptors in autism: an autoradiographic study.

    PubMed

    Blatt, G J; Fitzgerald, C M; Guptill, J T; Booker, A B; Kemper, T L; Bauman, M L

    2001-12-01

    Neuropathological studies in autistic brains have shown small neuronal size and increased cell packing density in a variety of limbic system structures including the hippocampus, a change consistent with curtailment of normal development. Based on these observations in the hippocampus, a series of quantitative receptor autoradiographic studies were undertaken to determine the density and distribution of eight types of neurotransmitter receptors from four neurotransmitter systems (GABAergic, serotoninergic [5-HT], cholinergic, and glutamatergic). Data from these single concentration ligand binding studies indicate that the GABAergic receptor system (3[H]-flunitrazepam labeled benzodiazepine binding sites and 3[H]-muscimol labeled GABA(A) receptors) is significantly reduced in high binding regions, marking for the first time an abnormality in the GABA system in autism. In contrast, the density and distribution of the other six receptors studied (3[H]-80H-DPAT labeled 5-HT1A receptors, 3[H]-ketanserin labeled 5-HT2 receptors, 3[H]-pirenzepine labled M1 receptors, 3[H]-hemicholinium labeled high affinity choline uptake sites, 3[H]-MK801 labeled NMDA receptors, and 3[H]-kainate labeled kainate receptors) in the hippocampus did not demonstrate any statistically significant differences in binding.

  15. Quantitative autoradiographic mapping of herpes simplex virus encephalitis with a radiolabeled antiviral drug

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saito, Y.; Price, R.W.; Rottenberg, D.A.

    1982-09-17

    2'-Fluoro-5-methyl-1-..beta..-D-arabinosyluracil (FMAU) labeled with carbon-14 was used to image herpes simplex virus type 1-infected regions of rat brain by quantitative autoradiography. FMAU is a potent antiviral pyrimidine nucleoside which is selectively phosphorylated by virus-coded thymidine kinase. When the labeled FMAU was administered 6 hours before the rats were killed, the selective uptake and concentration of the drug and its metabolites by infected cells (defined by immunoperoxidase staining of viral antigens) allowed quantitative definition and mapping of HSV-1-infected structures in autoradiograms of brain sections. These results shown that quantitative autoradiography can be used to characterize the local metabolism of antiviral drugsmore » by infected cells in vivo. They also suggest that the selective uptake of drugs that exploit viral thymidine kinase for their antiviral effect can, by appropriate labeling, be used in conjunction with clinical neuroimaging techniques to define infected regions of human brain, thereby providing a new approach to the diagnosis of herpes encephalitis in man.« less

  16. Autoradiographic Distribution and Applied Pharmacological Characteristics of Dextromethorphan and Related Antitissue/Anticonvulsant Drugs and Novel Analogs

    DTIC Science & Technology

    1991-11-01

    CHARACTERISTICS OF DEXTROMETHORPHAN AND RELATED ANTITISSUE/ANTICONVULSANT DRUGS AND NOVEL ANALOGS SUBTITLE: Receptor Binding of Dextromethorphan in Normal and...FUNDING NUMBERS Autoradiographic Distribution and Applied Pharmacologica. Characteristics of Dextromethorphan and Related Antitiss e/ Anticonvulsant...Developnent Command Fort Detrick Frederick, Maryland 21702-5012 11. SUPPLEMENTARY NOTES Subtitle: Receptor Binding of Dextromethorphan in Normal and

  17. Autoradiographic Distribution and Applied Pharmacological Characteristics of Dextromethorphan and Related Antitissue/Anticonvulsant Drugs and Novel Analogs

    DTIC Science & Technology

    1993-10-01

    AD-A273 247 AD____ CONTRACT NO: DAMD17-90-C-0124 TITLE: AUTORADIOGRAPHIC DISTRIBUTION AND APPLIED PHARMACOLOGICAL CHARACTERISTICS OF DEXTROMETHORPHAN ...Anticonvulsants, Antitissue, Dextromethorphan , Autoradiography, Pharmacokinetics 16. PRICE CODE 17. SECURITY CLASSIFICATION 18. SECURITY CLASSIFICATION...middle cerebral artery occlusion model with dextromethorphan , carbetapentane and three of the carbetapentane analogues, 11, B and D, which were

  18. Detection of antisalivary duct antibody from Sjögren's syndrome by an autoradiographic method.

    PubMed

    Cummings, N A; Tarpley, T M

    1978-01-01

    A new technique to detect anti-salivary duct antibody (ASDA) has been developed by using autoradiographic, rather than immunofluorescent methods. The antibody activity detected by autoradiography is probably classic ASDA. Both techniques may be consecutively performed on the same tissue section without attenuation of either. Some of the potential advantages of the radiolabelling of ASDA are pointed out, and a few preliminary experiments using the labelled antibody as a marker are presented.

  19. PERFILS: a program for the quantitative treatment of footprinting data.

    PubMed

    Salas, X; Portugal, J

    1993-10-01

    PERFILS, a computer program written in Borland TurboPascal, performs quantitative analysis of footprinting experiments using any IBM PC or compatible microcomputer. The program uses the height of the bands obtained from densitometric scanning of footprinting autoradiographs to calculate a differential cleavage plot. Such a plot displays, on a logarithmic scale, the difference of susceptibility of a DNA fragment to DNase I, or any other cleaving agent, in the presence of any ligand versus the sequence. PERFILS calculates the fractional cleavage values for control and ligand, giving a table of values for each internucleotidic bond and rendering the differential cleavage plot in only a few seconds.

  20. INTRACELLULAR LOCALIZATION AND QUANTITATION OF TRITIATED ANTIGENS IN RETICULOENDOTHELIAL TISSUES OF MICE DURING SECONDARY AND HYPERIMMUNE RESPONSES

    PubMed Central

    Roberts, Audrey N.; Haurowitz, Felix

    1962-01-01

    Autoradiography and quantitative radiochemical techniques have been used to determine intracellular localization of tritium and the quantity of tissue-bound tritium, respectively, following injections of H3-aniline azo PGG or H3-arsanilazo PGG to yield hyperimmune or secondary response stimulation in mice. Autoradiography revealed intracytoplasmic localization of grains in macrophages of spleen and lung sections, and in Kupffer cells of liver sections following intravenous and subcutaneous injections of H3-aniline azo PGG. Quantitation of tissue section surface radioactivities in the windowless flow counter and scintillation counter, and of dissolved tissue section activities in the scintillation counter, showed that greatest radioactivity was present in lung tissue, with less in spleen, liver, and mesenteric lymph nodes from these hyperimmunized mice. Autoradiographic studies on tissue sections from mice in secondary response stimulation after subcutaneous foot-pad injections of H3-arsanilazo PGG, showed intracellular and extracellular grains over regional popliteal node sections, with intracytoplasmic grain localization over macrophages and pyroninophilic plasmacytes. Scattered macrophages in spleen and lung sections also contained intracytoplasmic radioactivity. Clusters of antibody-synthesizing cells in the regional lymph nodes were demonstrated with fluorescence microscopy, and these cells were compared to similar cells possessing radioactivity as observed in the section autoradiographs. An occasional Russell body plasma cell containing specific antibody was observed in splenic impressions. Windowless flow counting showed that greatest radioactivity was in regional node sections, with less in spleen and lung, and none in contralateral lymph nodes. A quantitative comparison between windowless flow counting and autoradiography revealed that 20 counts were required to yield one silver grain. PMID:13974279

  1. Autoradiographic analysis of binding sites for sup 125 I-Bolton-Hunter-substance P in the human eye

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kieselbach, G.F.; Ragaut, R.; Knaus, H.G.

    1990-07-01

    Substance P is known to exert potent effects in peripheral tissues, and is thought to be important for ocular function. The mechanism of action of substance P in the human eye is not known. As a basis for biochemical characterization specific binding of {sup 125}I-Bolton-Hunter-substance P was demonstrated in the human eye using autoradiographic methods. Biochemical characterization on slide-mounted tissue preparations showed that binding was saturable with a KD of 0.27 +/- 0.1 nmol/l. Specific binding occurred at comparable autoradiographic densities to both human retina and choroid. Substance P and its carboxyterminal fragment, substance P(3-11), were shown to be highlymore » potent in binding competition experiments against {sup 125}I-Bolton-Hunter-substance P. Similar concentrations of substance P(1-9), neurokinin A and neurokinin B failed to significantly alter specific binding of {sup 125}I-Bolton-Hunter-substance P. The results indicate expression of high affinity substance P binding sites in human retina and choroid.« less

  2. Development and Measurement of Preschoolers' Quantitative Knowledge

    ERIC Educational Resources Information Center

    Geary, David C.

    2015-01-01

    The collection of studies in this special issue make an important contribution to our understanding and measurement of the core cognitive and noncognitive factors that influence children's emerging quantitative competencies. The studies also illustrate how the field has matured, from a time when the quantitative competencies of infants and young…

  3. Connecting qualitative observation and quantitative measurement for enhancing quantitative literacy in plant anatomy course

    NASA Astrophysics Data System (ADS)

    Nuraeni, E.; Rahmat, A.

    2018-05-01

    Forming of cognitive schemes of plant anatomy concepts is performed by processing of qualitative and quantitative data obtained from microscopic observations. To enhancing student’s quantitative literacy, strategy of plant anatomy course was modified by adding the task to analyze quantitative data produced by quantitative measurement of plant anatomy guided by material course. Participant in this study was 24 biology students and 35 biology education students. Quantitative Literacy test, complex thinking in plant anatomy test and questioner used to evaluate the course. Quantitative literacy capability data was collected by quantitative literacy test with the rubric from the Association of American Colleges and Universities, Complex thinking in plant anatomy by test according to Marzano and questioner. Quantitative literacy data are categorized according to modified Rhodes and Finley categories. The results showed that quantitative literacy of biology education students is better than biology students.

  4. Site of anticonvulsant action on sodium channels: autoradiographic and electrophysiological studies in rat brain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Worley, P.F.; Baraban, J.M.

    1987-05-01

    The anticonvulsants phenytoin and carbamazepine interact allosterically with the batrachotoxin binding site of sodium channels. In the present study, we demonstrate an autoradiographic technique to localize the batrachotoxin binding site on sodium channels in rat brain using (/sup 3/H)batrachotoxinin-A 20-alpha-benzoate (BTX-B). Binding of (/sup 3/H)BTX-B to brain sections is dependent on potentiating allosteric interactions with scorpion venom and is displaced by BTX-B (Kd approximately 200 nM), aconitine, veratridine, and phenytoin with the same rank order of potencies as described in brain synaptosomes. The maximum number of (/sup 3/H)BTX-B binding sites in forebrain sections also agrees with biochemical determinations. Autoradiographic localizationsmore » indicate that (/sup 3/H)BTX-B binding sites are not restricted to cell bodies and axons but are present in synaptic zones throughout the brain. For example, a particularly dense concentration of these sites in the substantia nigra is associated with afferent terminals of the striatonigral projection. By contrast, myelinated structures possess much lower densities of binding sites. In addition, we present electrophysiological evidence that synaptic transmission, as opposed to axonal conduction, is preferentially sensitive to the action of aconitine and veratridine. Finally, the synaptic block produced by these sodium channel activators is inhibited by phenytoin and carbamazepine at therapeutic anticonvulsant concentrations.« less

  5. Electric Field Quantitative Measurement System and Method

    NASA Technical Reports Server (NTRS)

    Generazio, Edward R. (Inventor)

    2016-01-01

    A method and system are provided for making a quantitative measurement of an electric field. A plurality of antennas separated from one another by known distances are arrayed in a region that extends in at least one dimension. A voltage difference between at least one selected pair of antennas is measured. Each voltage difference is divided by the known distance associated with the selected pair of antennas corresponding thereto to generate a resulting quantity. The plurality of resulting quantities defined over the region quantitatively describe an electric field therein.

  6. Autoradiographic Distribution and Applied Pharmacological Characteristics of Dextromethorphan and Related Antitissue/Anticonvulsant Drugs and Novel Analogs.

    DTIC Science & Technology

    1994-10-01

    Human Brain PRINCIPAL INVESTIGATOR: Professor Norman G. Bowery CONTRACTING ORGANIZATION: University of London Department of Pharmacology The School...Rat and Human Brain 12a. DISTRIBUTION / AVAILABILITY STATEMENT 12b. DISTRIBUTION CODE Approved for public release; distribution unlimited 13. ABSTRACT...DM ’bindinj was clearly not a marker for the degree of neuronal damage. At autoradiographic technique is als( being developed for examining the binding

  7. Densities of Serotonergic Projections as Revealed by In Situ Synthesised Labelled α-Methyl-Serotonin: an Autoradiographic Evaluation

    PubMed Central

    Nishi, Kyoko; Takahashi, Sho

    2013-01-01

    An estimate of serotonergic innervation density and regional serotonin (5-HT) concentration was performed from the distribution of in situ produced labelled α-methyl-serotonin. Rats were injected with (3H) labelled α-methyl-L-tryptophan and the tracer distribution was measured using the autoradiographic method 14 days following the injection. In a separate experiment, the total brain concentration of 5-HT in the rat brain was found to be 2.4 ± 0.2 nmol/g. Based on this, and the assumption that the specific activity of in situ produced α-methyl-serotonin is the same as that of the injected tracer, it was possible to estimate the regional concentrations of 5-HT and the relative concentration of regional serotonergic innervations. It was found, and reported for the first time here, that the highest concentration of serotonergic innervation is present in the solitary nucleus. Regionally measured 5-HT concentrations accord well with previously reported concentrations of 5-HT. PMID:21472458

  8. Quantitative measures for redox signaling.

    PubMed

    Pillay, Ché S; Eagling, Beatrice D; Driscoll, Scott R E; Rohwer, Johann M

    2016-07-01

    Redox signaling is now recognized as an important regulatory mechanism for a number of cellular processes including the antioxidant response, phosphokinase signal transduction and redox metabolism. While there has been considerable progress in identifying the cellular machinery involved in redox signaling, quantitative measures of redox signals have been lacking, limiting efforts aimed at understanding and comparing redox signaling under normoxic and pathogenic conditions. Here we have outlined some of the accepted principles for redox signaling, including the description of hydrogen peroxide as a signaling molecule and the role of kinetics in conferring specificity to these signaling events. Based on these principles, we then develop a working definition for redox signaling and review a number of quantitative methods that have been employed to describe signaling in other systems. Using computational modeling and published data, we show how time- and concentration- dependent analyses, in particular, could be used to quantitatively describe redox signaling and therefore provide important insights into the functional organization of redox networks. Finally, we consider some of the key challenges with implementing these methods. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. The Relationship between Quantitative and Qualitative Measures of Writing Skills.

    ERIC Educational Resources Information Center

    Howerton, Mary Lou P.; And Others

    The relationships of quantitative measures of writing skills to overall writing quality as measured by the E.T.S. Composition Evaluation Scale (CES) were examined. Quantitative measures included indices of language productivity, vocabulary diversity, spelling, and syntactic maturity. Power of specific indices to account for variation in overall…

  10. Separation of input function for rapid measurement of quantitative CMRO2 and CBF in a single PET scan with a dual tracer administration method

    NASA Astrophysics Data System (ADS)

    Kudomi, Nobuyuki; Watabe, Hiroshi; Hayashi, Takuya; Iida, Hidehiro

    2007-04-01

    Cerebral metabolic rate of oxygen (CMRO2), oxygen extraction fraction (OEF) and cerebral blood flow (CBF) images can be quantified using positron emission tomography (PET) by administrating 15O-labelled water (H152O) and oxygen (15O2). Conventionally, those images are measured with separate scans for three tracers C15O for CBV, H152O for CBF and 15O2 for CMRO2, and there are additional waiting times between the scans in order to minimize the influence of the radioactivity from the previous tracers, which results in a relatively long study period. We have proposed a dual tracer autoradiographic (DARG) approach (Kudomi et al 2005), which enabled us to measure CBF, OEF and CMRO2 rapidly by sequentially administrating H152O and 15O2 within a short time. Because quantitative CBF and CMRO2 values are sensitive to arterial input function, it is necessary to obtain accurate input function and a drawback of this approach is to require separation of the measured arterial blood time-activity curve (TAC) into pure water and oxygen input functions under the existence of residual radioactivity from the first injected tracer. For this separation, frequent manual sampling was required. The present paper describes two calculation methods: namely a linear and a model-based method, to separate the measured arterial TAC into its water and oxygen components. In order to validate these methods, we first generated a blood TAC for the DARG approach by combining the water and oxygen input functions obtained in a series of PET studies on normal human subjects. The combined data were then separated into water and oxygen components by the present methods. CBF and CMRO2 were calculated using those separated input functions and tissue TAC. The quantitative accuracy in the CBF and CMRO2 values by the DARG approach did not exceed the acceptable range, i.e., errors in those values were within 5%, when the area under the curve in the input function of the second tracer was larger than half of the

  11. Characterization and autoradiographic localization of neurotensin binding sites in human sigmoid colon.

    PubMed

    Azriel, Y; Burcher, E

    2001-06-01

    Radioiodinated neurotensin ((125)I-NT) was used to characterize and localize NT binding sites in normal human sigmoid colon. Specimens were obtained from patients (30-77 years old) undergoing resection for colon carcinoma. Specific binding of (125)I-NT to sigmoid circular muscle membranes was enhanced by o-phenanthroline (1 mM) but other peptidase inhibitors were ineffective. (125)I-NT bound to a high-affinity site of K(d) = 0.88 +/- 0.09 nM and B(max) = 4.03 +/- 0.66 fmol/mg of wet weight tissue (n = 14), although in the majority of patients another site, of low but variable affinity, could also be detected. Specific binding of 50 pM (125)I-NT was inhibited by NT(8-13) > NT > SR142948A > or = neuromedin N > or = SR48692, consistent with binding to the NT1 receptor. In autoradiographic studies, dense specific binding of (125)I-NT was seen over myenteric and submucosal ganglia, moderate binding over circular muscle, and sparse binding over longitudinal muscle and taenia coli. Levocabastine, which has affinity for the NT2 receptor, did not inhibit specific binding of (125)I-NT in membrane competition or autoradiographic studies. NT contracted sigmoid colon circular muscle strips with a pD(2) value of 6.8 +/- 0.2 nM (n = 25). The contractile responses to NT were significantly potentiated in the presence of tetrodotoxin (1 microM), indicating a neural component. Results from functional studies support actions for NT on both muscle and enteric neurons, consistent with the presence of NT receptors on circular muscle and ganglia of human sigmoid colon. The lack of inhibition by levocabastine suggests that the second binding site detected does not correspond to the NT2 receptor.

  12. Quantitative force measurements using frequency modulation atomic force microscopy—theoretical foundations

    NASA Astrophysics Data System (ADS)

    Sader, John E.; Uchihashi, Takayuki; Higgins, Michael J.; Farrell, Alan; Nakayama, Yoshikazu; Jarvis, Suzanne P.

    2005-03-01

    Use of the atomic force microscope (AFM) in quantitative force measurements inherently requires a theoretical framework enabling conversion of the observed deflection properties of the cantilever to an interaction force. In this paper, the theoretical foundations of using frequency modulation atomic force microscopy (FM-AFM) in quantitative force measurements are examined and rigorously elucidated, with consideration being given to both 'conservative' and 'dissipative' interactions. This includes a detailed discussion of the underlying assumptions involved in such quantitative force measurements, the presentation of globally valid explicit formulae for evaluation of so-called 'conservative' and 'dissipative' forces, discussion of the origin of these forces, and analysis of the applicability of FM-AFM to quantitative force measurements in liquid.

  13. Smile line assessment comparing quantitative measurement and visual estimation.

    PubMed

    Van der Geld, Pieter; Oosterveld, Paul; Schols, Jan; Kuijpers-Jagtman, Anne Marie

    2011-02-01

    Esthetic analysis of dynamic functions such as spontaneous smiling is feasible by using digital videography and computer measurement for lip line height and tooth display. Because quantitative measurements are time-consuming, digital videography and semiquantitative (visual) estimation according to a standard categorization are more practical for regular diagnostics. Our objective in this study was to compare 2 semiquantitative methods with quantitative measurements for reliability and agreement. The faces of 122 male participants were individually registered by using digital videography. Spontaneous and posed smiles were captured. On the records, maxillary lip line heights and tooth display were digitally measured on each tooth and also visually estimated according to 3-grade and 4-grade scales. Two raters were involved. An error analysis was performed. Reliability was established with kappa statistics. Interexaminer and intraexaminer reliability values were high, with median kappa values from 0.79 to 0.88. Agreement of the 3-grade scale estimation with quantitative measurement showed higher median kappa values (0.76) than the 4-grade scale estimation (0.66). Differentiating high and gummy smile lines (4-grade scale) resulted in greater inaccuracies. The estimation of a high, average, or low smile line for each tooth showed high reliability close to quantitative measurements. Smile line analysis can be performed reliably with a 3-grade scale (visual) semiquantitative estimation. For a more comprehensive diagnosis, additional measuring is proposed, especially in patients with disproportional gingival display. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  14. Autoradiographic localization of endothelin-1 binding sites in porcine skin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Y.D.; Springall, D.R.; Wharton, J.

    Autoradiographic techniques and {sup 125}I-labeled endothelin-1 were used to study the distribution of endothelin-1 binding sites in porcine skin. Specific endothelin-1 binding sites were localized to blood vessels (capillaries, deep cutaneous vascular plexus, arteries, and arterioles), the deep dermal and connective tissue sheath of hair follicles, sebaceous and sweat glands, and arrector pili muscle. Specific binding was inhibited by endothelin-2 and endothelin-3 as well as endothelin-1. Non-specific binding was found in the epidermis and the medulla of hair follicles. No binding was found in connective tissue or fat. These vascular binding sites may represent endothelin receptors, in keeping with themore » known cutaneous vasoconstrictor actions of the peptide. If all binding sites are receptors, the results suggest that endothelin could also regulate the function of sweat glands and may have trophic effects in the skin.« less

  15. Evaluation of airway protection: Quantitative timing measures versus penetration/aspiration score.

    PubMed

    Kendall, Katherine A

    2017-10-01

    Quantitative measures of swallowing function may improve the reliability and accuracy of modified barium swallow (MBS) study interpretation. Quantitative study analysis has not been widely instituted, however, secondary to concerns about the time required to make measures and a lack of research demonstrating impact on MBS interpretation. This study compares the accuracy of the penetration/aspiration (PEN/ASP) scale (an observational visual-perceptual assessment tool) to quantitative measures of airway closure timing relative to the arrival of the bolus at the upper esophageal sphincter in identifying a failure of airway protection during deglutition. Retrospective review of clinical swallowing data from a university-based outpatient clinic. Swallowing data from 426 patients were reviewed. Patients with normal PEN/ASP scores were identified, and the results of quantitative airway closure timing measures for three liquid bolus sizes were evaluated. The incidence of significant airway closure delay with and without a normal PEN/ASP score was determined. Inter-rater reliability for the quantitative measures was calculated. In patients with a normal PEN/ASP score, 33% demonstrated a delay in airway closure on at least one swallow during the MBS study. There was no correlation between PEN/ASP score and airway closure delay. Inter-rater reliability for the quantitative measure of airway closure timing was nearly perfect (intraclass correlation coefficient = 0.973). The use of quantitative measures of swallowing function, in conjunction with traditional visual perceptual methods of MBS study interpretation, improves the identification of airway closure delay, and hence, potential aspiration risk, even when no penetration or aspiration is apparent on the MBS study. 4. Laryngoscope, 127:2314-2318, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  16. Quantitative endoscopy: initial accuracy measurements.

    PubMed

    Truitt, T O; Adelman, R A; Kelly, D H; Willging, J P

    2000-02-01

    The geometric optics of an endoscope can be used to determine the absolute size of an object in an endoscopic field without knowing the actual distance from the object. This study explores the accuracy of a technique that estimates absolute object size from endoscopic images. Quantitative endoscopy involves calibrating a rigid endoscope to produce size estimates from 2 images taken with a known traveled distance between the images. The heights of 12 samples, ranging in size from 0.78 to 11.80 mm, were estimated with this calibrated endoscope. Backup distances of 5 mm and 10 mm were used for comparison. The mean percent error for all estimated measurements when compared with the actual object sizes was 1.12%. The mean errors for 5-mm and 10-mm backup distances were 0.76% and 1.65%, respectively. The mean errors for objects <2 mm and > or =2 mm were 0.94% and 1.18%, respectively. Quantitative endoscopy estimates endoscopic image size to within 5% of the actual object size. This method remains promising for quantitatively evaluating object size from endoscopic images. It does not require knowledge of the absolute distance of the endoscope from the object, rather, only the distance traveled by the endoscope between images.

  17. Indium adhesion provides quantitative measure of surface cleanliness

    NASA Technical Reports Server (NTRS)

    Krieger, G. L.; Wilson, G. J.

    1968-01-01

    Indium tipped probe measures hydrophobic and hydrophilic contaminants on rough and smooth surfaces. The force needed to pull the indium tip, which adheres to a clean surface, away from the surface provides a quantitative measure of cleanliness.

  18. Simultaneous Feulgen densitometry and autoradiographic grain counting with the Quantimet 720D image-analysis system. III. Improvements in Feulgen densitometry.

    PubMed

    Sklarew, R J

    1983-10-01

    A method has been developed for densitometric estimation of the Feulgen-stained DNA content of 3H-labeled nuclei in autoradiographs in conjunction with automated grain counting using a Quantimet Imaging System. Refinements in the methodology are reported which include 1) the incorporation of an Image-Editor Module into the Quantimet module configuration; 2) the optimization of incident illumination based upon evaluation of various light sources; 3) changes in the optical configuration which reduce glare and minimize the level of monitor shading correction; 4) the optimization of scanner sensitivity; and 5) the evaluation of cell-flattening and staining with respect to densitometry resolution and sensitivity. These refinements resulted in a CV of less than 6.4% in the G-1 and G-2 DNA peaks of rat kidney cells in autoradiographs compared to the previous CV of 10.5%, and a G-2 to G-1 ratio of 2.025. For a fixed field position the CV was 5.1% and the replication error less than 1.0%.

  19. Three-dimensional autoradiographic localization of quench-corrected glycine receptor specific activity in the mouse brain using sup 3 H-strychnine as the ligand

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, W.F.; O'Gorman, S.; Roe, A.W.

    1990-03-01

    The autoradiographic analysis of neurotransmitter receptor distribution is a powerful technique that provides extensive information on the localization of neurotransmitter systems. Computer methodologies are described for the analysis of autoradiographic material which include quench correction, 3-dimensional display, and quantification based on anatomical boundaries determined from the tissue sections. These methodologies are applied to the problem of the distribution of glycine receptors measured by 3H-strychnine binding in the mouse CNS. The most distinctive feature of this distribution is its marked caudorostral gradient. The highest densities of binding sites within this gradient were seen in somatic motor and sensory areas; high densitiesmore » of binding were seen in branchial efferent and special sensory areas. Moderate levels were seen in nuclei related to visceral function. Densities within the reticular formation paralleled the overall gradient with high to moderate levels of binding. The colliculi had low and the diencephalon had very low levels of binding. No binding was seen in the cerebellum or the telencephalon with the exception of the amygdala, which had very low levels of specific binding. This distribution of glycine receptors correlates well with the known functional distribution of glycine synaptic function. These data are illustrated in 3 dimensions and discussed in terms of the significance of the analysis techniques on this type of data as well as the functional significance of the distribution of glycine receptors.« less

  20. Quantitative tomographic measurements of opaque multiphase flows

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    GEORGE,DARIN L.; TORCZYNSKI,JOHN R.; SHOLLENBERGER,KIM ANN

    2000-03-01

    An electrical-impedance tomography (EIT) system has been developed for quantitative measurements of radial phase distribution profiles in two-phase and three-phase vertical column flows. The EIT system is described along with the computer algorithm used for reconstructing phase volume fraction profiles. EIT measurements were validated by comparison with a gamma-densitometry tomography (GDT) system. The EIT system was used to accurately measure average solid volume fractions up to 0.05 in solid-liquid flows, and radial gas volume fraction profiles in gas-liquid flows with gas volume fractions up to 0.15. In both flows, average phase volume fractions and radial volume fraction profiles from GDTmore » and EIT were in good agreement. A minor modification to the formula used to relate conductivity data to phase volume fractions was found to improve agreement between the methods. GDT and EIT were then applied together to simultaneously measure the solid, liquid, and gas radial distributions within several vertical three-phase flows. For average solid volume fractions up to 0.30, the gas distribution for each gas flow rate was approximately independent of the amount of solids in the column. Measurements made with this EIT system demonstrate that EIT may be used successfully for noninvasive, quantitative measurements of dispersed multiphase flows.« less

  1. Nerves and Tissue Repair.

    DTIC Science & Technology

    1992-05-21

    complete dependence on nerves. Organ culture of sciatic nerves, combined with an assay for axolotl transferrin developed earlier, allows quantitative study...axonal release of various unknown proteins. Combining this approach with the ELISA for quantitative measurement of axolotl transferrin developed with...light microscope autoradiographic analysis following binding of radiolabelled Tf. Studies of Tf synthesis will employ cDNA probes for axolotl Tf mRNA

  2. Quantitative measurement of marginal disintegration of ceramic inlays.

    PubMed

    Hayashi, Mikako; Tsubakimoto, Yuko; Takeshige, Fumio; Ebisu, Shigeyuki

    2004-01-01

    The objectives of this study include establishing a method for quantitative measurement of marginal change in ceramic inlays and clarifying their marginal disintegration in vivo. An accurate CCD optical laser scanner system was used for morphological measurement of the marginal change of ceramic inlays. The accuracy of the CCD measurement was assessed by comparing it with microscopic measurement. Replicas of 15 premolars restored with Class II ceramic inlays at the time of placement and eight years after restoration were used for morphological measurement by means of the CCD laser scanner system. Occlusal surfaces of the restored teeth were scanned and cross-sections of marginal areas were computed with software. Marginal change was defined as the area enclosed by two profiles obtained by superimposing two cross-sections of the same location at two different times and expressing the maximum depth and mean area of the area enclosed. The accuracy of this method of measurement was 4.3 +/- 3.2 microm in distance and 2.0 +/- 0.6% in area. Quantitative marginal changes for the eight-year period were 10 x 10 microm in depth and 50 x 10(3) microm2 in area at the functional cusp area and 7 x 10 microm in depth and 28 x 10(3) microm2 in area at the non-functional cusp area. Marginal disintegration at the functional cusp area was significantly greater than at the non-functional cusp area (Wilcoxon signed-ranks test, p < 0.05). This study constitutes a quantitative measurement of in vivo deterioration in marginal adaptation of ceramic inlays and indicates that occlusal force may accelerate marginal disintegration.

  3. Quantitative force measurements in liquid using frequency modulation atomic force microscopy

    NASA Astrophysics Data System (ADS)

    Uchihashi, Takayuki; Higgins, Michael J.; Yasuda, Satoshi; Jarvis, Suzanne P.; Akita, Seiji; Nakayama, Yoshikazu; Sader, John E.

    2004-10-01

    The measurement of short-range forces with the atomic force microscope (AFM) typically requires implementation of dynamic techniques to maintain sensitivity and stability. While frequency modulation atomic force microscopy (FM-AFM) is used widely for high-resolution imaging and quantitative force measurements in vacuum, quantitative force measurements using FM-AFM in liquids have proven elusive. Here we demonstrate that the formalism derived for operation in vacuum can also be used in liquids, provided certain modifications are implemented. To facilitate comparison with previous measurements taken using surface forces apparatus, we choose a model system (octamethylcyclotetrasiloxane) that is known to exhibit short-ranged structural ordering when confined between two surfaces. Force measurements obtained are found to be in excellent agreement with previously reported results. This study therefore establishes FM-AFM as a powerful tool for the quantitative measurement of forces in liquid.

  4. A general way for quantitative magnetic measurement by transmitted electrons

    NASA Astrophysics Data System (ADS)

    Song, Dongsheng; Li, Gen; Cai, Jianwang; Zhu, Jing

    2016-01-01

    EMCD (electron magnetic circular dichroism) technique opens a new door to explore magnetic properties by transmitted electrons. The recently developed site-specific EMCD technique makes it possible to obtain rich magnetic information from the Fe atoms sited at nonequivalent crystallographic planes in NiFe2O4, however it is based on a critical demand for the crystallographic structure of the testing sample. Here, we have further improved and tested the method for quantitative site-specific magnetic measurement applicable for more complex crystallographic structure by using the effective dynamical diffraction effects (general routine for selecting proper diffraction conditions, making use of the asymmetry of dynamical diffraction for design of experimental geometry and quantitative measurement, etc), and taken yttrium iron garnet (Y3Fe5O12, YIG) with more complex crystallographic structure as an example to demonstrate its applicability. As a result, the intrinsic magnetic circular dichroism signals, spin and orbital magnetic moment of iron with site-specific are quantitatively determined. The method will further promote the development of quantitative magnetic measurement with high spatial resolution by transmitted electrons.

  5. Autoradiographic assay of mutants resistant to diphtheria toxin in mammalian cells in vitro

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ronen, A.; Gingerich, J.D.; Duncan, A.M.V.

    1984-10-01

    Diptheria toxin kills mammalian cells by ribosylating elongation factor 2, a protein factor necessary for protein synthesis. The frequency of cells able to form colonies in the presence of the toxin can be used as an assay for mutation to diphtheria toxin resistance. Resistance to diphtheria toxin can also be detected autoradiographically in cells exposed to (/sup 3/H)leucine after treatment with the toxin. In cultures of Chinese hamster ovary cells, the frequency of such resistant cells is increased by exposure of the cells to ..gamma..-rays, ultraviolet light, ethylnitrosourea, mitomycin c, ethidium bromide, and 5-bromo-2'-deoxyuridine in a dose- and time-dependent manner.more » The resistant cells form discrete microcolonies if they are allowed to divide several times before intoxication which indicates that they are genuine mutants. The assay is potentially adaptable to any cell population that can be intoxicated with diphtheria toxin and labeled with (/sup 3/H)leucine, whether or not the cells can form colonies. It may be useful, therefore, for measuring mutation rates in slowly growing or nondividing cell populations such as breast, brain, and liver, as well as in cells that do divide but cannot be readily cloned, such as the colonic epithelium. 23 references, 6 figures.« less

  6. The calibration of video cameras for quantitative measurements

    NASA Technical Reports Server (NTRS)

    Snow, Walter L.; Childers, Brooks A.; Shortis, Mark R.

    1993-01-01

    Several different recent applications of velocimetry at Langley Research Center are described in order to show the need for video camera calibration for quantitative measurements. Problems peculiar to video sensing are discussed, including synchronization and timing, targeting, and lighting. The extension of the measurements to include radiometric estimates is addressed.

  7. Quantitative angle-insensitive flow measurement using relative standard deviation OCT

    NASA Astrophysics Data System (ADS)

    Zhu, Jiang; Zhang, Buyun; Qi, Li; Wang, Ling; Yang, Qiang; Zhu, Zhuqing; Huo, Tiancheng; Chen, Zhongping

    2017-10-01

    Incorporating different data processing methods, optical coherence tomography (OCT) has the ability for high-resolution angiography and quantitative flow velocity measurements. However, OCT angiography cannot provide quantitative information of flow velocities, and the velocity measurement based on Doppler OCT requires the determination of Doppler angles, which is a challenge in a complex vascular network. In this study, we report on a relative standard deviation OCT (RSD-OCT) method which provides both vascular network mapping and quantitative information for flow velocities within a wide range of Doppler angles. The RSD values are angle-insensitive within a wide range of angles, and a nearly linear relationship was found between the RSD values and the flow velocities. The RSD-OCT measurement in a rat cortex shows that it can quantify the blood flow velocities as well as map the vascular network in vivo.

  8. Quantitative angle-insensitive flow measurement using relative standard deviation OCT.

    PubMed

    Zhu, Jiang; Zhang, Buyun; Qi, Li; Wang, Ling; Yang, Qiang; Zhu, Zhuqing; Huo, Tiancheng; Chen, Zhongping

    2017-10-30

    Incorporating different data processing methods, optical coherence tomography (OCT) has the ability for high-resolution angiography and quantitative flow velocity measurements. However, OCT angiography cannot provide quantitative information of flow velocities, and the velocity measurement based on Doppler OCT requires the determination of Doppler angles, which is a challenge in a complex vascular network. In this study, we report on a relative standard deviation OCT (RSD-OCT) method which provides both vascular network mapping and quantitative information for flow velocities within a wide range of Doppler angles. The RSD values are angle-insensitive within a wide range of angles, and a nearly linear relationship was found between the RSD values and the flow velocities. The RSD-OCT measurement in a rat cortex shows that it can quantify the blood flow velocities as well as map the vascular network in vivo .

  9. Quantitative Species Measurements In Microgravity Combustion Flames

    NASA Technical Reports Server (NTRS)

    Chen, Shin-Juh; Pilgrim, Jeffrey S.; Silver, Joel A.; Piltch, Nancy D.

    2003-01-01

    The capability of models and theories to accurately predict and describe the behavior of low gravity flames can only be verified by quantitative measurements. Although video imaging, simple temperature measurements, and velocimetry methods have provided useful information in many cases, there is still a need for quantitative species measurements. Over the past decade, we have been developing high sensitivity optical absorption techniques to permit in situ, non-intrusive, absolute concentration measurements for both major and minor flames species using diode lasers. This work has helped to establish wavelength modulation spectroscopy (WMS) as an important method for species detection within the restrictions of microgravity-based measurements. More recently, in collaboration with Prof. Dahm at the University of Michigan, a new methodology combining computed flame libraries with a single experimental measurement has allowed us to determine the concentration profiles for all species in a flame. This method, termed ITAC (Iterative Temperature with Assumed Chemistry) was demonstrated for a simple laminar nonpremixed methane-air flame at both 1-g and at 0-g in a vortex ring flame. In this paper, we report additional normal and microgravity experiments which further confirm the usefulness of this approach. We also present the development of a new type of laser. This is an external cavity diode laser (ECDL) which has the unique capability of high frequency modulation as well as a very wide tuning range. This will permit the detection of multiple species with one laser while using WMS detection.

  10. Autoradiographic evidence for two classes of mu opioid binding sites in rat brain using (/sup 125/I)FK33824

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rothman, R.B.; Jacobson, A.E.; Rice, K.C.

    1987-11-01

    Previous studies demonstrated that pretreatment of brain membranes with the irreversible mu antagonist, beta-funaltrexamine (beta-FNA), partially eliminated mu binding sites (25,35), consistent with the existence of two mu binding sites distinguished by beta-FNA. This paper tests the hypothesis that the FNA-sensitive and FNA-insensitive mu binding sites have different anatomical distributions in rat brain. Prior to autoradiographic visualization of mu binding sites, (/sup 3/H)oxymorphone, (/sup 3/H)D-ala2-MePhe4, Gly-ol5-enkephalin (DAGO), and (/sup 125/I)D-ala2-Me-Phe4-met(o)-ol)enkephalin (FK33824) were shown to selectively label mu binding sites using slide mounted sections of molded minced rat brain. As found using membranes, beta-FNA eliminated only a portion of mu bindingmore » sites. Autoradiographic visualization of mu binding sites using the mu-selective ligand (/sup 125/I)FK33824 in control and FNA-treated sections of rat brain demonstrated that the proportion of mu binding sites sensitive to beta-FNA varied across regions of the brain, particularly the dorsal thalamus, ventrobasal complex and the hypothalamus, providing anatomical data supporting the existence of two classes of mu binding sites in rat brain.« less

  11. On Measuring Quantitative Interpretations of Reasonable Doubt

    ERIC Educational Resources Information Center

    Dhami, Mandeep K.

    2008-01-01

    Beyond reasonable doubt represents a probability value that acts as the criterion for conviction in criminal trials. I introduce the membership function (MF) method as a new tool for measuring quantitative interpretations of reasonable doubt. Experiment 1 demonstrated that three different methods (i.e., direct rating, decision theory based, and…

  12. Prediction of Coronal Mass Ejections From Vector Magnetograms: Quantitative Measures as Predictors

    NASA Technical Reports Server (NTRS)

    Falconer, D. A.; Moore, R. L.; Gary, G. A.; Rose, M. Franklin (Technical Monitor)

    2001-01-01

    We derived two quantitative measures of an active region's global nonpotentiality from the region's vector magnetogram, 1) the net current (I(sub N)), and 2) the length of strong-shear, strong-field main neutral line (Lss), and used these two measures in a pilot study of the CME productivity of 4 active regions. We compared the global nonpotentiality measures to the active regions' CME productivity determined from GOES and Yohkoh/SXT observations. We found that two of the active regions were highly globally nonpotential and were CME productive, while the other two active regions had little global nonpotentiality and produced no CMEs. At the Fall 2000 AGU, we reported on an expanded study (12 active regions and 17 magnetograms) in which we evaluated four quantitative global measures of an active region's magnetic field and compared these measures with the CME productivity. The four global measures (all derived from MSFC vector magnetograms) included our two previous measures (I(sub N) and L(sub ss)) as well as two new ones, the total magnetic flux (PHI) (a measure of an active region's size), and the normalized twist (alpha (bar)= muIN/PHI). We found that the three quantitative measures of global nonpotentiality (I(sub N), L(sub ss), alpha (bar)) were all well correlated (greater than 99% confidence level) with an active region's CME productivity within plus or minus 2 days of the day of the magnetogram. We will now report on our findings of how good our quantitative measures are as predictors of active-region CME productivity, using only CMEs that occurred after the magnetogram. We report the preliminary skill test of these quantitative measures as predictors. We compare the CME prediction success of our quantitative measures to the CME prediction success based on an active region's past CME productivity. We examine the cases of the handful of false positive and false negatives to look for improvements to our predictors. This work is funded by NSF through the Space

  13. Quantitative color measurement for black walnut wood.

    Treesearch

    Ali A. Moslemi

    1967-01-01

    Black walnut (Juglans nigra L.) veneer specimens with wide variations in color were evaluated by a quantitative method of color measurement. The internationally adopted CIE system of colorimetry was used to analyze the data. These data were converted to also show them in the Munsell system. Color differences among the walnut veneer specimens were also numerically...

  14. SERS quantitative urine creatinine measurement of human subject

    NASA Astrophysics Data System (ADS)

    Wang, Tsuei Lian; Chiang, Hui-hua K.; Lu, Hui-hsin; Hung, Yung-da

    2005-03-01

    SERS method for biomolecular analysis has several potentials and advantages over traditional biochemical approaches, including less specimen contact, non-destructive to specimen, and multiple components analysis. Urine is an easily available body fluid for monitoring the metabolites and renal function of human body. We developed surface-enhanced Raman scattering (SERS) technique using 50nm size gold colloidal particles for quantitative human urine creatinine measurements. This paper shows that SERS shifts of creatinine (104mg/dl) in artificial urine is from 1400cm-1 to 1500cm-1 which was analyzed for quantitative creatinine measurement. Ten human urine samples were obtained from ten healthy persons and analyzed by the SERS technique. Partial least square cross-validation (PLSCV) method was utilized to obtain the estimated creatinine concentration in clinically relevant (55.9mg/dl to 208mg/dl) concentration range. The root-mean square error of cross validation (RMSECV) is 26.1mg/dl. This research demonstrates the feasibility of using SERS for human subject urine creatinine detection, and establishes the SERS platform technique for bodily fluids measurement.

  15. Quantitative Measurement of Trans-Fats by Infrared Spectroscopy

    ERIC Educational Resources Information Center

    Walker, Edward B.; Davies, Don R.; Campbell, Mike

    2007-01-01

    Trans-fat is a general term, which is mainly used to describe the various trans geometric isomers present in unsaturated fatty acids. Various techniques are now used for a quantitative measurement of the amount of trans-fats present in foods and cooking oil.

  16. Measurement Invariance: A Foundational Principle for Quantitative Theory Building

    ERIC Educational Resources Information Center

    Nimon, Kim; Reio, Thomas G., Jr.

    2011-01-01

    This article describes why measurement invariance is a critical issue to quantitative theory building within the field of human resource development. Readers will learn what measurement invariance is and how to test for its presence using techniques that are accessible to applied researchers. Using data from a LibQUAL+[TM] study of user…

  17. Racial Differences in Quantitative Measures of Area and Volumetric Breast Density

    PubMed Central

    McCarthy, Anne Marie; Keller, Brad M.; Pantalone, Lauren M.; Hsieh, Meng-Kang; Synnestvedt, Marie; Conant, Emily F.; Armstrong, Katrina; Kontos, Despina

    2016-01-01

    Abstract Background: Increased breast density is a strong risk factor for breast cancer and also decreases the sensitivity of mammographic screening. The purpose of our study was to compare breast density for black and white women using quantitative measures. Methods: Breast density was assessed among 5282 black and 4216 white women screened using digital mammography. Breast Imaging-Reporting and Data System (BI-RADS) density was obtained from radiologists’ reports. Quantitative measures for dense area, area percent density (PD), dense volume, and volume percent density were estimated using validated, automated software. Breast density was categorized as dense or nondense based on BI-RADS categories or based on values above and below the median for quantitative measures. Logistic regression was used to estimate the odds of having dense breasts by race, adjusted for age, body mass index (BMI), age at menarche, menopause status, family history of breast or ovarian cancer, parity and age at first birth, and current hormone replacement therapy (HRT) use. All statistical tests were two-sided. Results: There was a statistically significant interaction of race and BMI on breast density. After accounting for age, BMI, and breast cancer risk factors, black women had statistically significantly greater odds of high breast density across all quantitative measures (eg, PD nonobese odds ratio [OR] = 1.18, 95% confidence interval [CI] = 1.02 to 1.37, P = .03, PD obese OR = 1.26, 95% CI = 1.04 to 1.53, P = .02). There was no statistically significant difference in BI-RADS density by race. Conclusions: After accounting for age, BMI, and other risk factors, black women had higher breast density than white women across all quantitative measures previously associated with breast cancer risk. These results may have implications for risk assessment and screening. PMID:27130893

  18. A Framework for Mixing Methods in Quantitative Measurement Development, Validation, and Revision: A Case Study

    ERIC Educational Resources Information Center

    Luyt, Russell

    2012-01-01

    A framework for quantitative measurement development, validation, and revision that incorporates both qualitative and quantitative methods is introduced. It extends and adapts Adcock and Collier's work, and thus, facilitates understanding of quantitative measurement development, validation, and revision as an integrated and cyclical set of…

  19. Prediction of Coronal Mass Ejections from Vector Magnetograms: Quantitative Measures as Predictors

    NASA Astrophysics Data System (ADS)

    Falconer, D. A.; Moore, R. L.; Gary, G. A.

    2001-05-01

    In a pilot study of 4 active regions (Falconer, D.A. 2001, JGR, in press), we derived two quantitative measures of an active region's global nonpotentiality from the region's vector magnetogram, 1) the net current (IN), and 2) the length of the strong-shear, strong-field main neutral line (LSS), and used these two measures of the CME productivity of the active regions. We compared the global nonpotentiality measures to the active regions' CME productivity determined from GOES and Yohkoh/SXT observations. We found that two of the active regions were highly globally nonpotential and were CME productive, while the other two active regions had little global nonpotentiality and produced no CMEs. At the Fall 2000 AGU (Falconer, Moore, & Gary, 2000, EOS 81, 48 F998), we reported on an expanded study (12 active regions and 17 magnetograms) in which we evaluated four quantitative global measures of an active region's magnetic field and compared these measures with the CME productivity. The four global measures (all derived from MSFC vector magnetograms) included our two previous measures (IN and LSS) as well as two new ones, the total magnetic flux (Φ ) (a measure of an active region's size), and the normalized twist (α =μ IN/Φ ). We found that the three measures of global nonpotentiality (IN, LSS, α ) were all well correlated (>99% confidence level) with an active region's CME productivity within (2 days of the day of the magnetogram. We will now report on our findings of how good our quantitative measures are as predictors of active-region CME productivity, using only CMEs that occurred after the magnetogram. We report the preliminary skill test of these quantitative measures as predictors. We compare the CME prediction success of our quantitative measures to the CME prediction success based on an active region's past CME productivity. We examine the cases of the handful of false positive and false negatives to look for improvements to our predictors. This work is

  20. Quantitative measures detect sensory and motor impairments in multiple sclerosis.

    PubMed

    Newsome, Scott D; Wang, Joseph I; Kang, Jonathan Y; Calabresi, Peter A; Zackowski, Kathleen M

    2011-06-15

    Sensory and motor dysfunction in multiple sclerosis (MS) is often assessed with rating scales which rely heavily on clinical judgment. Quantitative devices may be more precise than rating scales. To quantify lower extremity sensorimotor measures in individuals with MS, evaluate the extent to which they can detect functional systems impairments, and determine their relationship to global disability measures. We tested 145 MS subjects and 58 controls. Vibration thresholds were quantified using a Vibratron-II device. Strength was quantified by a hand-held dynamometer. We also recorded Expanded Disability Status Scale (EDSS) and Timed 25-Foot Walk (T25FW). t-tests and Wilcoxon-rank sum were used to compare group data. Spearman correlations were used to assess relationships between each measure. We also used a step-wise linear regression model to determine how much the quantitative measures explain the variance in the respective functional systems scores (FSS). EDSS scores ranged from 0-7.5, mean disease duration was 10.4 ± 9.6 years, and 66% were female. In relapsing-remitting MS, but not progressive MS, poorer vibration sensation correlated with a worse EDSS score, whereas progressive groups' ankle/hip strength changed significantly with EDSS progression. Interestingly, not only did sensorimotor measures significantly correlate with global disability measures (i.e., EDSS), but they had improved sensitivity, as they detected impairments in up to 32% of MS subjects with normal sensory and pyramidal FSS. Sensory and motor deficits in MS can be quantified using clinically accessible tools and distinguish differences among MS subtypes. We show that quantitative sensorimotor measures are more sensitive than FSS from the EDSS. These tools have the potential to be used as clinical outcome measures in practice and for future MS clinical trials of neurorehabilitative and neuroreparative interventions. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Quantitative measures detect sensory and motor impairments in multiple sclerosis

    PubMed Central

    Newsome, Scott D.; Wang, Joseph I.; Kang, Jonathan Y.; Calabresi, Peter A.; Zackowski, Kathleen M.

    2011-01-01

    Background Sensory and motor dysfunction in multiple sclerosis (MS) is often assessed with rating scales which rely heavily on clinical judgment. Quantitative devices may be more precise than rating scales. Objective To quantify lower extremity sensorimotor measures in individuals with MS, evaluate the extent to which they can detect functional systems impairments, and determine their relationship to global disability measures. Methods We tested 145 MS subjects and 58 controls. Vibration thresholds were quantified using a Vibratron-II device. Strength was quantified by a hand-held dynamometer. We also recorded Expanded Disability Status Scale (EDSS) and timed 25-foot walk (T25FW). T-tests and Wilcoxon-rank sum were used to compare group data. Spearman correlations were used to assess relationships between each measure. We also used a step-wise linear regression model to determine how much the quantitative measures explain the variance in the respective functional systems scores (FSS). Results EDSS scores ranged from 0-7.5, mean disease duration was 10.4±9.6 years, and 66% were female. In RRMS, but not progressive MS, poorer vibration sensation correlated with a worse EDSS score, whereas progressive groups’ ankle/hip strength changed significantly with EDSS progression. Interestingly, not only did sensorimotor measures significantly correlate with global disability measures (EDSS), but they had improved sensitivity, as they detected impairments in up to 32% of MS subjects with normal sensory FSS. Conclusions Sensory and motor deficits can be quantified using clinically accessible tools and distinguish differences among MS subtypes. We show that quantitative sensorimotor measures are more sensitive than FSS from the EDSS. These tools have the potential to be used as clinical outcome measures in practice and for future MS clinical trials of neurorehabilitative and neuroreparative interventions. PMID:21458828

  2. Differentiation of the epidermis in turtle: an immunocytochemical, autoradiographic and electrophoretic analysis.

    PubMed

    Alibardi, Lorenzo; Spisni, Enzo; Toni, Mattia

    2004-01-01

    Proteins involved in the process of cornification of turtle epidermis are not well known. The present immunocytochemical, electrophoretic and autoradiographic study reports on the localization patterns and molecular weights of keratins, which are cornification proteins, and of tritiated histidine in turtle epidermis. Alpha-keratins with a molecular weight of 40-62 kDa are present in the epidermis. Beta-keratin is mainly detectable in the stratum corneum of the carapace and plastron, but is rarely present or even absent in the corneous layer of limb, tail and neck epidermis. After electrophoresis and immunoblotting with an antibody against chicken scale beta-keratin, bands at 15-17, 22-24, and 36-38 kDa appeared. This antibody recognized weaker bands at 38-40 and 58-60 kDa in the soft epidermis. After reduction and carboxymethylation of proteins extracted from carapace and plastron, but not of proteins from the soft epidermis, protein bands at 15-17 and 35-37 kDa were found when using the anti-beta 1-keratin antibody. Loricrin-, filaggrin-, sciellin-, and transglutaminase-like immunostaining was detectable only in the transitional and lowermost corneous layers of the soft epidermis. Vesicular bodies in the transitional layer were immunolabeled by the anti-loricrin antibody, and weakly by the anti-filaggrin and anti-transglutaminase antibodies. In immunoblots, the anti-loricrin antibody reacted with a major band at 50-54 kDa in both carapace-plastron and soft epidermis. The anti-sciellin antibody detected major bands at 38-40 and 50 kDa in hard epidermis, and at 50 and 54-56 kDa in soft epidermis. Filaggrin-like immunostained bands were observed at 50-55 and 62-64 kDa. This immunostaining was probably due to a common epitope in filaggrin and some keratins. Histidine was evenly incorporated in the epidermis, and the ultrastructural study showed random labeling, often associated with keratin bundles of alpha and beta-keratinocytes. Histidine-labeled protein bands were

  3. Cleavage Entropy as Quantitative Measure of Protease Specificity

    PubMed Central

    Fuchs, Julian E.; von Grafenstein, Susanne; Huber, Roland G.; Margreiter, Michael A.; Spitzer, Gudrun M.; Wallnoefer, Hannes G.; Liedl, Klaus R.

    2013-01-01

    A purely information theory-guided approach to quantitatively characterize protease specificity is established. We calculate an entropy value for each protease subpocket based on sequences of cleaved substrates extracted from the MEROPS database. We compare our results with known subpocket specificity profiles for individual proteases and protease groups (e.g. serine proteases, metallo proteases) and reflect them quantitatively. Summation of subpocket-wise cleavage entropy contributions yields a measure for overall protease substrate specificity. This total cleavage entropy allows ranking of different proteases with respect to their specificity, separating unspecific digestive enzymes showing high total cleavage entropy from specific proteases involved in signaling cascades. The development of a quantitative cleavage entropy score allows an unbiased comparison of subpocket-wise and overall protease specificity. Thus, it enables assessment of relative importance of physicochemical and structural descriptors in protease recognition. We present an exemplary application of cleavage entropy in tracing substrate specificity in protease evolution. This highlights the wide range of substrate promiscuity within homologue proteases and hence the heavy impact of a limited number of mutations on individual substrate specificity. PMID:23637583

  4. Performing Repeated Quantitative Small-Animal PET with an Arterial Input Function Is Routinely Feasible in Rats.

    PubMed

    Huang, Chi-Cheng; Wu, Chun-Hu; Huang, Ya-Yao; Tzen, Kai-Yuan; Chen, Szu-Fu; Tsai, Miao-Ling; Wu, Hsiao-Ming

    2017-04-01

    Performing quantitative small-animal PET with an arterial input function has been considered technically challenging. Here, we introduce a catheterization procedure that keeps a rat physiologically stable for 1.5 mo. We demonstrated the feasibility of quantitative small-animal 18 F-FDG PET in rats by performing it repeatedly to monitor the time course of variations in the cerebral metabolic rate of glucose (CMR glc ). Methods: Aseptic surgery was performed on 2 rats. Each rat underwent catheterization of the right femoral artery and left femoral vein. The catheters were sealed with microinjection ports and then implanted subcutaneously. Over the next 3 wk, each rat underwent 18 F-FDG quantitative small-animal PET 6 times. The CMR glc of each brain region was calculated using a 3-compartment model and an operational equation that included a k* 4 Results: On 6 mornings, we completed 12 18 F-FDG quantitative small-animal PET studies on 2 rats. The rats grew steadily before and after the 6 quantitative small-animal PET studies. The CMR glc of the conscious brain (e.g., right parietal region, 99.6 ± 10.2 μmol/100 g/min; n = 6) was comparable to that for 14 C-deoxyglucose autoradiographic methods. Conclusion: Maintaining good blood patency in catheterized rats is not difficult. Longitudinal quantitative small-animal PET imaging with an arterial input function can be performed routinely. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  5. Quantitation of absorbed or deposited materials on a substrate that measures energy deposition

    DOEpatents

    Grant, Patrick G.; Bakajin, Olgica; Vogel, John S.; Bench, Graham

    2005-01-18

    This invention provides a system and method for measuring an energy differential that correlates to quantitative measurement of an amount mass of an applied localized material. Such a system and method remains compatible with other methods of analysis, such as, for example, quantitating the elemental or isotopic content, identifying the material, or using the material in biochemical analysis.

  6. Adipose tissue MRI for quantitative measurement of central obesity.

    PubMed

    Poonawalla, Aziz H; Sjoberg, Brett P; Rehm, Jennifer L; Hernando, Diego; Hines, Catherine D; Irarrazaval, Pablo; Reeder, Scott B

    2013-03-01

    To validate adipose tissue magnetic resonance imaging (atMRI) for rapid, quantitative volumetry of visceral adipose tissue (VAT) and total adipose tissue (TAT). Data were acquired on normal adults and clinically overweight girls with Institutional Review Board (IRB) approval/parental consent using sagittal 6-echo 3D-spoiled gradient-echo (SPGR) (26-sec single-breath-hold) at 3T. Fat-fraction images were reconstructed with quantitative corrections, permitting measurement of a physiologically based fat-fraction threshold in normals to identify adipose tissue, for automated measurement of TAT, and semiautomated measurement of VAT. TAT accuracy was validated using oil phantoms and in vivo TAT/VAT measurements validated with manual segmentation. Group comparisons were performed between normals and overweight girls using TAT, VAT, VAT-TAT-ratio (VTR), body-mass-index (BMI), waist circumference, and waist-hip-ratio (WHR). Oil phantom measurements were highly accurate (<3% error). The measured adipose fat-fraction threshold was 96% ± 2%. VAT and TAT correlated strongly with manual segmentation (normals r(2) ≥ 0.96, overweight girls r(2) ≥ 0.99). VAT segmentation required 30 ± 11 minutes/subject (14 ± 5 sec/slice) using atMRI, versus 216 ± 73 minutes/subject (99 ± 31 sec/slice) manually. Group discrimination was significant using WHR (P < 0.001) and VTR (P = 0.004). The atMRI technique permits rapid, accurate measurements of TAT, VAT, and VTR. Copyright © 2012 Wiley Periodicals, Inc.

  7. Advanced quantitative measurement methodology in physics education research

    NASA Astrophysics Data System (ADS)

    Wang, Jing

    parts. The first part involves the comparison between item response theory (IRT) and classical test theory (CTT). The two theories both provide test item statistics for educational inferences and decisions. The two theories are both applied to Force Concept Inventory data obtained from students enrolled in The Ohio State University. Effort was made to examine the similarity and difference between the two theories, and the possible explanation to the difference. The study suggests that item response theory is more sensitive to the context and conceptual features of the test items than classical test theory. The IRT parameters provide a better measure than CTT parameters for the educational audience to investigate item features. The second part of the dissertation is on the measure of association for binary data. In quantitative assessment, binary data is often encountered because of its simplicity. The current popular measures of association fail under some extremely unbalanced conditions. However, the occurrence of these conditions is not rare in educational data. Two popular association measures, the Pearson's correlation and the tetrachoric correlation are examined. A new method, model based association is introduced, and an educational testing constraint is discussed. The existing popular methods are compared with the model based association measure with and without the constraint. Connections between the value of association and the context and conceptual features of questions are discussed in detail. Results show that all the methods have their advantages and disadvantages. Special attention to the test and data conditions is necessary. The last part of the dissertation is focused on exploratory factor analysis (EFA). The theoretical advantages of EFA are discussed. Typical misunderstanding and misusage of EFA are explored. The EFA is performed on Lawson's Classroom Test of Scientific Reasoning (LCTSR), a widely used assessment on scientific reasoning skills. The

  8. Radioligand binding, autoradiographic and functional studies demonstrate tachykinin NK-2 receptors in dog urinary bladder.

    PubMed

    Mussap, C J; Stamatakos, C; Burcher, E

    1996-10-01

    Tachykinin receptors in the dog bladder were characterized using radioligand binding, functional and autoradiographic techniques. In detrusor muscle homogenates, specific binding of [125l]iodohistidyl neurokinin A (INKA) and [125l]Bolton Hunter eledoisin was reversible, saturable and, to a single class of sites of Kd, 3,6 and 27 nM, respectively. No specific binding of [125l]Bolton Hunter[Sar9, Met (O2)11] substance P occurred. INKA binding was reduced by the peptidase inhibitor bacitracin. The rank potency order of agonists competing for binding of both radioligands indicated interaction at NK-2 sites. NK-2-selective antagonists also competed for INKA binding, with SR 48968, GR 94800, MDL 29913 and the selective agonist [Lys5, MeLeu9, Nle10]-NKA(4-10) showing biphasic binding profiles. Autoradiographic studies revealed specific binding of INKA and [125l]Bolton Hunter eledoisin over detrusor muscle and small arteries. [125l]Bolton Hunter [Sar9, Met (O2)11] SP labeled the intima of arteries and arterioles, but not the detrusor muscle. Tachykinins contracted detrusor muscle strips, with potency order at the carbachol EC15 NKA = kassinin > [Lys5, MeLeu9, Nle10]-NKA(4-10) = neuropeptide gamma = neuropeptide K = NKB > > MDL 28564, with [Sar9, Met(O2)11]-SP ineffective. Shallow concentration-response curves, variable efficacies and inhibition by atropine and mepyramine suggest that other mechanisms may influence contractile responses. Responses to [Lys5, MeLeu9, Nle10]-NKA(4-10) were inhibited competitively by MDL 29913 and MEN 10207 (pA2 values: 6.4 and 5.3, respectively). Antagonism by SR 48968 and GR 94800 was noncompetitive (both pK8 values 8.9). In summary, NK-2-preferring ligands showed superior potency as both binding competitors and contractile agonists, demonstrating that NK-2 receptors mediate detrusor muscle contraction, similar to the human detrusor. Tachykinins may play important roles in the micturition reflex and in regulating detrusor muscle blood flow in

  9. Uranium in bone: metabolic and autoradiographic studies in the rat.

    PubMed

    Priest, N D; Howells, G R; Green, D; Haines, J W

    1982-03-01

    The distribution and retention of intravenously injected hexavalent uranium-233 in the skeleton of the female rat has been investigated using a variety of autoradiographic and radiochemical techniques. These showed that approximately one third of the injected uranium is deposited in the skeleton where it is retained with an initial biological half-time of approximately 40 days. The studies also showed that: 1 Uranium is initially deposited onto all types of bone surface, but preferentially onto those that are accreting. 2 Uranium is deposited in the calcifying zones of skeletal cartilage. 3 Bone accretion results in the burial of surface deposits of uranium. 4 Bone resorption causes the removal of uranium from surfaces. 5 Resorbed uranium is not retained by osteoclasts and macrophages in the bone marrow. 6 Uranium removed from bone surfaces enters the bloodstream where most is either redeposited in bone or excreted via the kidneys. 7 The recycling of resorbed uranium within the skeleton tends to produce a uniform level of uranium contamination throughout mineralized bone. These results are taken to indicate that uranium deposition in bone shares characteristics in common with both the 'volume-seeking radionuclides' typified by the alkaline earth elements and with the 'bone surface-seeking radionuclides' typified by plutonium.

  10. Initial Description of a Quantitative, Cross-Species (Chimpanzee-Human) Social Responsiveness Measure

    ERIC Educational Resources Information Center

    Marrus, Natasha; Faughn, Carley; Shuman, Jeremy; Petersen, Steve E.; Constantino, John N.; Povinelli, Daniel J.; Pruett, John R., Jr.

    2011-01-01

    Objective: Comparative studies of social responsiveness, an ability that is impaired in autism spectrum disorders, can inform our understanding of both autism and the cognitive architecture of social behavior. Because there is no existing quantitative measure of social responsiveness in chimpanzees, we generated a quantitative, cross-species…

  11. Exercise training reinstates cortico-cortical sensorimotor functional connectivity following striatal lesioning: Development and application of a subregional-level analytic toolbox for perfusion autoradiographs of the rat brain

    NASA Astrophysics Data System (ADS)

    Peng, Yu-Hao; Heintz, Ryan; Wang, Zhuo; Guo, Yumei; Myers, Kalisa; Scremin, Oscar; Maarek, Jean-Michel; Holschneider, Daniel

    2014-12-01

    Current rodent connectome projects are revealing brain structural connectivity with unprecedented resolution and completeness. How subregional structural connectivity relates to subregional functional interactions is an emerging research topic. We describe a method for standardized, mesoscopic-level data sampling from autoradiographic coronal sections of the rat brain, and for correlation-based analysis and intuitive display of cortico-cortical functional connectivity (FC) on a flattened cortical map. A graphic user interface “Cx-2D” allows for the display of significant correlations of individual regions-of-interest, as well as graph theoretical metrics across the cortex. Cx-2D was tested on an autoradiographic data set of cerebral blood flow (CBF) of rats that had undergone bilateral striatal lesions, followed by 4 weeks of aerobic exercise training or no exercise. Effects of lesioning and exercise on cortico-cortical FC were examined during a locomotor challenge in this rat model of Parkinsonism. Subregional FC analysis revealed a rich functional reorganization of the brain in response to lesioning and exercise that was not apparent in a standard analysis focused on CBF of isolated brain regions. Lesioned rats showed diminished degree centrality of lateral primary motor cortex, as well as neighboring somatosensory cortex--changes that were substantially reversed in lesioned rats following exercise training. Seed analysis revealed that exercise increased positive correlations in motor and somatosensory cortex, with little effect in non-sensorimotor regions such as visual, auditory, and piriform cortex. The current analysis revealed that exercise partially reinstated sensorimotor FC lost following dopaminergic deafferentation. Cx-2D allows for standardized data sampling from images of brain slices, as well as analysis and display of cortico-cortical FC in the rat cerebral cortex with potential applications in a variety of autoradiographic and histologic

  12. Improvement of Quantitative Measurements in Multiplex Proteomics Using High-Field Asymmetric Waveform Spectrometry.

    PubMed

    Pfammatter, Sibylle; Bonneil, Eric; Thibault, Pierre

    2016-12-02

    Quantitative proteomics using isobaric reagent tandem mass tags (TMT) or isobaric tags for relative and absolute quantitation (iTRAQ) provides a convenient approach to compare changes in protein abundance across multiple samples. However, the analysis of complex protein digests by isobaric labeling can be undermined by the relative large proportion of co-selected peptide ions that lead to distorted reporter ion ratios and affect the accuracy and precision of quantitative measurements. Here, we investigated the use of high-field asymmetric waveform ion mobility spectrometry (FAIMS) in proteomic experiments to reduce sample complexity and improve protein quantification using TMT isobaric labeling. LC-FAIMS-MS/MS analyses of human and yeast protein digests led to significant reductions in interfering ions, which increased the number of quantifiable peptides by up to 68% while significantly improving the accuracy of abundance measurements compared to that with conventional LC-MS/MS. The improvement in quantitative measurements using FAIMS is further demonstrated for the temporal profiling of protein abundance of HEK293 cells following heat shock treatment.

  13. Measurements in quantitative research: how to select and report on research instruments.

    PubMed

    Hagan, Teresa L

    2014-07-01

    Measures exist to numerically represent degrees of attributes. Quantitative research is based on measurement and is conducted in a systematic, controlled manner. These measures enable researchers to perform statistical tests, analyze differences between groups, and determine the effectiveness of treatments. If something is not measurable, it cannot be tested.

  14. Quantitative measurement of intervertebral disc signal using MRI.

    PubMed

    Niemeläinen, R; Videman, T; Dhillon, S S; Battié, M C

    2008-03-01

    To investigate the spinal cord as an alternative intra-body reference to cerebrospinal fluid (CSF) in evaluating thoracic disc signal intensity. T2-weighted magnetic resonance imaging (MRI) images of T6-T12 were obtained using 1.5 T machines for a population-based sample of 523 men aged 35-70 years. Quantitative data on the signal intensities were acquired using an image analysis program (SpEx). A random sample of 30 subjects and intraclass correlation coefficients (ICC) were used to examine the repeatability of the spinal cord measurements. The validity of using the spinal cord as a reference was examined by correlating cord and CSF samples. Finally, thoracic disc signal was validated by correlating it with age without adjustment and adjusting for either cord or CSF. Pearson's r was used for correlational analyses. The repeatability of the spinal cord signal measurements was extremely high (>or=0.99). The correlations between the signals of spinal cord and CSF by level were all above 0.9. The spinal cord-adjusted disc signal and age correlated similarly with CSF-adjusted disc signal and age (r=-0.30 to -0.40 versus r=-0.26 to -0.36). Adjacent spinal cord is a good alternative reference to the current reference standard, CSF, for quantitative measurements of disc signal intensity. Clearly fewer levels were excluded when using spinal cord as compared to CSF due to missing reference samples.

  15. Hematocrit Measurement with R2* and Quantitative Susceptibility Mapping in Postmortem Brain.

    PubMed

    Walsh, A J; Sun, H; Emery, D J; Wilman, A H

    2018-05-24

    Noninvasive venous oxygenation quantification with MR imaging will improve the neurophysiologic investigation and the understanding of the pathophysiology in neurologic diseases. Available MR imaging methods are limited by sensitivity to flow and often require assumptions of the hematocrit level. In situ postmortem imaging enables evaluation of methods in a fully deoxygenated environment without flow artifacts, allowing direct calculation of hematocrit. This study compares 2 venous oxygenation quantification methods in in situ postmortem subjects. Transverse relaxation (R2*) mapping and quantitative susceptibility mapping were performed on a whole-body 4.7T MR imaging system. Intravenous measurements in major draining intracranial veins were compared between the 2 methods in 3 postmortem subjects. The quantitative susceptibility mapping technique was also applied in 10 healthy control subjects and compared with reference venous oxygenation values. In 2 early postmortem subjects, R2* mapping and quantitative susceptibility mapping measurements within intracranial veins had a significant and strong correlation ( R 2 = 0.805, P = .004 and R 2 = 0.836, P = .02). Higher R2* and susceptibility values were consistently demonstrated within gravitationally dependent venous segments during the early postmortem period. Hematocrit ranged from 0.102 to 0.580 in postmortem subjects, with R2* and susceptibility as large as 291 seconds -1 and 1.75 ppm, respectively. Measurements of R2* and quantitative susceptibility mapping within large intracranial draining veins have a high correlation in early postmortem subjects. This study supports the use of quantitative susceptibility mapping for evaluation of in vivo venous oxygenation and postmortem hematocrit concentrations. © 2018 by American Journal of Neuroradiology.

  16. A Systematic Review of Quantitative Resilience Measures for Water Infrastructure Systems

    DOE PAGES

    Shin, Sangmin; Lee, Seungyub; Judi, David; ...

    2018-02-07

    Over the past few decades, the concept of resilience has emerged as an important consideration in the planning and management of water infrastructure systems. Accordingly, various resilience measures have been developed for the quantitative evaluation and decision-making of systems. There are, however, numerous considerations and no clear choice of which measure, if any, provides the most appropriate representation of resilience for a given application. This study provides a critical review of quantitative approaches to measure the resilience of water infrastructure systems, with a focus on water resources and distribution systems. A compilation of 11 criteria evaluating 21 selected resilience measuresmore » addressing major features of resilience is developed using the Axiomatic Design process. Existing gaps of resilience measures are identified based on the review criteria. The results show that resilience measures have generally paid less attention to cascading damage to interrelated systems, rapid identification of failure, physical damage of system components, and time variation of resilience. Concluding the paper, improvements to resilience measures are recommended. The findings contribute to our understanding of gaps and provide information to help further improve resilience measures of water infrastructure systems.« less

  17. A Systematic Review of Quantitative Resilience Measures for Water Infrastructure Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shin, Sangmin; Lee, Seungyub; Judi, David

    Over the past few decades, the concept of resilience has emerged as an important consideration in the planning and management of water infrastructure systems. Accordingly, various resilience measures have been developed for the quantitative evaluation and decision-making of systems. There are, however, numerous considerations and no clear choice of which measure, if any, provides the most appropriate representation of resilience for a given application. This study provides a critical review of quantitative approaches to measure the resilience of water infrastructure systems, with a focus on water resources and distribution systems. A compilation of 11 criteria evaluating 21 selected resilience measuresmore » addressing major features of resilience is developed using the Axiomatic Design process. Existing gaps of resilience measures are identified based on the review criteria. The results show that resilience measures have generally paid less attention to cascading damage to interrelated systems, rapid identification of failure, physical damage of system components, and time variation of resilience. Concluding the paper, improvements to resilience measures are recommended. The findings contribute to our understanding of gaps and provide information to help further improve resilience measures of water infrastructure systems.« less

  18. Quantitative phase measurement for wafer-level optics

    NASA Astrophysics Data System (ADS)

    Qu, Weijuan; Wen, Yongfu; Wang, Zhaomin; Yang, Fang; Huang, Lei; Zuo, Chao

    2015-07-01

    Wafer-level-optics now is widely used in smart phone camera, mobile video conferencing or in medical equipment that require tiny cameras. Extracting quantitative phase information has received increased interest in order to quantify the quality of manufactured wafer-level-optics, detect defective devices before packaging, and provide feedback for manufacturing process control, all at the wafer-level for high-throughput microfabrication. We demonstrate two phase imaging methods, digital holographic microscopy (DHM) and Transport-of-Intensity Equation (TIE) to measure the phase of the wafer-level lenses. DHM is a laser-based interferometric method based on interference of two wavefronts. It can perform a phase measurement in a single shot. While a minimum of two measurements of the spatial intensity of the optical wave in closely spaced planes perpendicular to the direction of propagation are needed to do the direct phase retrieval by solving a second-order differential equation, i.e., with a non-iterative deterministic algorithm from intensity measurements using the Transport-of-Intensity Equation (TIE). But TIE is a non-interferometric method, thus can be applied to partial-coherence light. We demonstrated the capability and disability for the two phase measurement methods for wafer-level optics inspection.

  19. The relationship between quantitative measures of disc height and disc signal intensity with Pfirrmann score of disc degeneration.

    PubMed

    Salamat, Sara; Hutchings, John; Kwong, Clemens; Magnussen, John; Hancock, Mark J

    2016-01-01

    To assess the relationship between quantitative measures of disc height and signal intensity with the Pfirrmann disc degeneration scoring system and to test the inter-rater reliability of the quantitative measures. Participants were 76 people who had recently recovered from their last episode of acute low back pain and underwent MRI scan on a single 3T machine. At all 380 lumbar discs, quantitative measures of disc height and signal intensity were made by 2 independent raters and compared to Pfirrmann scores from a single radiologist. For quantitative measures of disc height and signal intensity a "raw" score and 2 adjusted ratios were calculated and the relationship with Pfirrmann scores was assessed. The inter-tester reliability of quantitative measures was also investigated. There was a strong linear relationship between quantitative disc signal intensity and Pfirrmann scores for grades 1-4, but not for grades 4 and 5. For disc height only, Pfirrmann grade 5 had significantly reduced disc height compared to all other grades. Results were similar regardless of whether raw or adjusted scores were used. Inter-rater reliability for the quantitative measures was excellent (ICC > 0.97). Quantitative measures of disc signal intensity were strongly related to Pfirrmann scores from grade 1 to 4; however disc height only differentiated between grade 4 and 5 Pfirrmann scores. Using adjusted ratios for quantitative measures of disc height or signal intensity did not significantly alter the relationship with Pfirrmann scores.

  20. Quantitative Morphology Measures in Galaxies: Ground-Truthing from Simulations

    NASA Astrophysics Data System (ADS)

    Narayanan, Desika T.; Abruzzo, Matthew W.; Dave, Romeel; Thompson, Robert

    2017-01-01

    The process of galaxy assembly is a prevalent question in astronomy; there are a variety of potentially important effects, including baryonic accretion from the intergalactic medium, as well as major galaxy mergers. Recent years have ushered in the development of quantitative measures of morphology such as the Gini coefficient (G), the second-order moment of the brightest quintile of a galaxy’s light (M20), and the concentration (C), asymmetry (A), and clumpiness (S) of galaxies. To investigate the efficacy of these observational methods at identifying major mergers, we have run a series of very high resolution cosmological zoom simulations, and coupled these with 3D Monte Carlo dust radiative transfer. Our methodology is powerful in that it allows us to “observe” the simulation as an observer would, while maintaining detailed knowledge of the true merger history of the galaxy. In this presentation, we will present our main results from our analysis of these quantitative morphology measures, with a particular focus on high-redshift (z>2) systems.

  1. Detecting Genetic Interactions for Quantitative Traits Using m-Spacing Entropy Measure

    PubMed Central

    Yee, Jaeyong; Kwon, Min-Seok; Park, Taesung; Park, Mira

    2015-01-01

    A number of statistical methods for detecting gene-gene interactions have been developed in genetic association studies with binary traits. However, many phenotype measures are intrinsically quantitative and categorizing continuous traits may not always be straightforward and meaningful. Association of gene-gene interactions with an observed distribution of such phenotypes needs to be investigated directly without categorization. Information gain based on entropy measure has previously been successful in identifying genetic associations with binary traits. We extend the usefulness of this information gain by proposing a nonparametric evaluation method of conditional entropy of a quantitative phenotype associated with a given genotype. Hence, the information gain can be obtained for any phenotype distribution. Because any functional form, such as Gaussian, is not assumed for the entire distribution of a trait or a given genotype, this method is expected to be robust enough to be applied to any phenotypic association data. Here, we show its use to successfully identify the main effect, as well as the genetic interactions, associated with a quantitative trait. PMID:26339620

  2. Preparation of (125)I-ricin suitable as a probe for the autoradiographic localization of toxin binding sites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doebler, J.A.; Mayer, T.W.; Traub, R.K.

    1993-05-13

    The long term objectives of this research are to identify cellular binding sites for ricin and examine its organ distribution in mice following aerosol inhalation exposure. Preliminary studies relating to the synthesis and evaluation of (125 I)-ricin as an autoradiographic probe have been conducted. Non-radioactive (I)-ricin prepared using the Iodogen method was found to be non-toxic both in vivo and in vitro. Lactose was then added to the Iodogen reaction medium to block galactose-binding site associated tyrosines in an attempt to retain toxicity. However, this did not prevent iodination-induced loss of biological potency. We then switched to the lactoperoxidase methodmore » of iodination, which yielded an (I)-ricin preparation with toxicity comparable to that of native toxin.« less

  3. Challenge in Enhancing the Teaching and Learning of Variable Measurements in Quantitative Research

    ERIC Educational Resources Information Center

    Kee, Chang Peng; Osman, Kamisah; Ahmad, Fauziah

    2013-01-01

    Statistical analysis is one component that cannot be avoided in a quantitative research. Initial observations noted that students in higher education institution faced difficulty analysing quantitative data which were attributed to the confusions of various variable measurements. This paper aims to compare the outcomes of two approaches applied in…

  4. Quantitative NDA measurements of advanced reprocessing product materials containing uranium, neptunium, plutonium, and americium

    NASA Astrophysics Data System (ADS)

    Goddard, Braden

    The ability of inspection agencies and facility operators to measure powders containing several actinides is increasingly necessary as new reprocessing techniques and fuel forms are being developed. These powders are difficult to measure with nondestructive assay (NDA) techniques because neutrons emitted from induced and spontaneous fission of different nuclides are very similar. A neutron multiplicity technique based on first principle methods was developed to measure these powders by exploiting isotope-specific nuclear properties, such as the energy-dependent fission cross sections and the neutron induced fission neutron multiplicity. This technique was tested through extensive simulations using the Monte Carlo N-Particle eXtended (MCNPX) code and by one measurement campaign using the Active Well Coincidence Counter (AWCC) and two measurement campaigns using the Epithermal Neutron Multiplicity Counter (ENMC) with various (alpha,n) sources and actinide materials. Four potential applications of this first principle technique have been identified: (1) quantitative measurement of uranium, neptunium, plutonium, and americium materials; (2) quantitative measurement of mixed oxide (MOX) materials; (3) quantitative measurement of uranium materials; and (4) weapons verification in arms control agreements. This technique still has several challenges which need to be overcome, the largest of these being the challenge of having high-precision active and passive measurements to produce results with acceptably small uncertainties.

  5. Measuring teamwork in primary care: Triangulation of qualitative and quantitative data.

    PubMed

    Brown, Judith Belle; Ryan, Bridget L; Thorpe, Cathy; Markle, Emma K R; Hutchison, Brian; Glazier, Richard H

    2015-09-01

    This article describes the triangulation of qualitative dimensions, reflecting high functioning teams, with the results of standardized teamwork measures. The study used a mixed methods design using qualitative and quantitative approaches to assess teamwork in 19 Family Health Teams in Ontario, Canada. This article describes dimensions from the qualitative phase using grounded theory to explore the issues and challenges to teamwork. Two quantitative measures were used in the study, the Team Climate Inventory (TCI) and the Providing Effective Resources and Knowledge (PERK) scale. For the triangulation analysis, the mean scores of these measures were compared with the qualitatively derived ratings for the dimensions. The final sample for the qualitative component was 107 participants. The qualitative analysis identified 9 dimensions related to high team functioning such as common philosophy, scope of practice, conflict resolution, change management, leadership, and team evolution. From these dimensions, teams were categorized numerically as high, moderate, or low functioning. Three hundred seventeen team members completed the survey measures. Mean site scores for the TCI and PERK were 3.87 and 3.88, respectively (of 5). The TCI was associated will all dimensions except for team location, space allocation, and executive director leadership. The PERK was associated with all dimensions except team location. Data triangulation provided qualitative and quantitative evidence of what constitutes teamwork. Leadership was pivotal in forging a common philosophy and encouraging team collaboration. Teams used conflict resolution strategies and adapted to the changes they encountered. These dimensions advanced the team's evolution toward a high functioning team. (c) 2015 APA, all rights reserved).

  6. Quantitative measures of walking and strength provide insight into brain corticospinal tract pathology in multiple sclerosis.

    PubMed

    Fritz, Nora E; Keller, Jennifer; Calabresi, Peter A; Zackowski, Kathleen M

    2017-01-01

    At least 85% of individuals with multiple sclerosis report walking dysfunction as their primary complaint. Walking and strength measures are common clinical measures to mark increasing disability or improvement with rehabilitation. Previous studies have shown an association between strength or walking ability and spinal cord MRI measures, and strength measures with brainstem corticospinal tract magnetization transfer ratio. However, the relationship between walking performance and brain corticospinal tract magnetization transfer imaging measures and the contribution of clinical measurements of walking and strength to the underlying integrity of the corticospinal tract has not been explored in multiple sclerosis. The objectives of this study were explore the relationship of quantitative measures of walking and strength to whole-brain corticospinal tract-specific MRI measures and to determine the contribution of quantitative measures of function in addition to basic clinical measures (age, gender, symptom duration and Expanded Disability Status Scale) to structural imaging measures of the corticospinal tract. We hypothesized that quantitative walking and strength measures would be related to brain corticospinal tract-specific measures, and would provide insight into the heterogeneity of brain pathology. Twenty-nine individuals with relapsing-remitting multiple sclerosis (mean(SD) age 48.7 (11.5) years; symptom duration 11.9(8.7); 17 females; median[range] Expanded Disability Status Scale 4.0 [1.0-6.5]) and 29 age and gender-matched healthy controls (age 50.8(11.6) years; 20 females) participated in clinical tests of strength and walking (Timed Up and Go, Timed 25 Foot Walk, Two Minute Walk Test ) as well as 3 T imaging including diffusion tensor imaging and magnetization transfer imaging. Individuals with multiple sclerosis were weaker (p = 0.0024) and walked slower (p = 0.0013) compared to controls. Quantitative measures of walking and strength were

  7. Autoradiographic distribution of 5-HT7 receptors in the human brain using [3H]mesulergine: comparison to other mammalian species

    PubMed Central

    Martín-Cora, Francisco J; Pazos, Angel

    2003-01-01

    The main aim of this investigation was to delineate the distribution of the 5-HT7 receptor in human brain. Autoradiographic studies in guinea-pig and rat brain were also carried out in order to revisit and compare the anatomical distribution of 5-HT7 receptors in different mammalian species.Binding studies were performed in rat frontal cortex membranes using 10 nM [3H]mesulergine in the presence of raclopride (10 μM) and DOI (0.8 μM). Under these conditions, a binding site with pharmacological characteristics consistent with those of the 5-HT7 receptors was identified (rank order of binding affinity values: 5-CT>5-HT>5-MeOT>mesulergine ≈methiothepin>8-OH-DPAT=spiperone ≈(+)-butaclamol≫imipramine ≈(±)-pindolol≫ondansetron ≈clonidine ≈prazosin).The autoradiographic studies revealed that the anatomical distribution of 5-HT7 receptors throughout the human brain was heterogenous. High densities were found over the caudate and putamen nuclei, the pyramidal layer of the CA2 field of the hippocampus, the centromedial thalamic nucleus, and the dorsal raphe nucleus. The inner layer of the frontal cortex, the dentate gyrus of the hippocampus, the subthalamic nucleus and superior colliculus, among others, presented intermediate concentrations of 5-HT7 receptors. A similar brain anatomical distribution of 5-HT7 receptors was observed in all three mammalian species studied.By using [3H]mesulergine, we have mapped for the first time the anatomical distribution of 5-HT7 receptors in the human brain, overcoming the limitations previously found in radiometric studies with other radioligands, and also revisiting the distribution in guinea-pig and rat brain. PMID:14656806

  8. Longitudinal change in quantitative meniscus measurements in knee osteoarthritis--data from the Osteoarthritis Initiative.

    PubMed

    Bloecker, Katja; Wirth, W; Guermazi, A; Hitzl, W; Hunter, D J; Eckstein, F

    2015-10-01

    We aimed to apply 3D MRI-based measurement technology to studying 2-year change in quantitative measurements of meniscus size and position. Forty-seven knees from the Osteoarthritis Initiative with medial radiographic joint space narrowing had baseline and 2-year follow-up MRIs. Quantitative measures were obtained from manual segmentation of the menisci and tibia using coronal DESSwe images. The standardized response mean (SRM = mean/SD change) was used as measure of sensitivity to longitudinal change. Medial tibial plateau coverage decreased from 34.8% to 29.9% (SRM -0.82; p < 0.001). Change in medial meniscus extrusion in a central image (SRM 0.18) and in the central five slices (SRM 0.22) did not reach significance, but change in extrusion across the entire meniscus (SRM 0.32; p = 0.03) and in the relative area of meniscus extrusion (SRM 0.56; p < 0.001) did. There was a reduction in medial meniscus volume (10%; p < 0.001), width (7%; p < 0.001), and height (2%; p = 0.08); meniscus substance loss was strongest in the posterior (SRM -0.51; p = 0.001) and weakest in the anterior horn (SRM -0.15; p = 0.31). This pilot study reports, for the first time, longitudinal change in quantitative 3D meniscus measurements in knee osteoarthritis. It provides evidence of improved sensitivity to change of 3D measurements compared with single slice analysis. • First longitudinal MRI-based measurements of change of meniscus position and size. • Quantitative longitudinal evaluation of meniscus change in knee osteoarthritis. • Improved sensitivity to change of 3D measurements compared with single slice analysis.

  9. Quantitative colorectal cancer perfusion measurement by multidetector-row CT: does greater tumour coverage improve measurement reproducibility?

    PubMed

    Goh, V; Halligan, S; Gartner, L; Bassett, P; Bartram, C I

    2006-07-01

    The purpose of this study was to determine if greater z-axis tumour coverage improves the reproducibility of quantitative colorectal cancer perfusion measurements using CT. A 65 s perfusion study was acquired following intravenous contrast administration in 10 patients with proven colorectal cancer using a four-detector row scanner. This was repeated within 48 h using identical technical parameters to allow reproducibility assessment. Quantitative tumour blood volume, blood flow, mean transit time and permeability measurements were determined using commercially available software (Perfusion 3.0; GE Healthcare, Waukesha, WI) for data obtained from a 5 mm z-axis tumour coverage, and from a 20 mm z-axis tumour coverage. Measurement reproducibility was assessed using Bland-Altman statistics, for a 5 mm z-axis tumour coverage, and 20 mm z-axis tumour coverage, respectively. The mean difference (95% limits of agreement) for blood volume, blood flow, mean transit time and permeability were 0.04 (-2.50 to +2.43) ml/100 g tissue; +8.80 (-50.5 to +68.0) ml/100 g tissue/min; -0.99 (-8.19 to +6.20) seconds; and +1.20 (-5.42 to +7.83) ml/100 g tissue/min, respectively, for a 5 mm coverage, and -0.04 (-2.61 to +2.53) ml/100 g tissue; +7.40 (-50.3 to +65.0) ml/100 g tissue/min; -2.46 (-12.61 to +7.69) seconds; and -0.23 (-8.31 to +7.85) ml/100 g tissue/min, respectively, for a 20 mm coverage, indicating similar levels of agreement. In conclusion, increasing z-axis coverage does not improve reproducibility of quantitative colorectal cancer perfusion measurements.

  10. Quantitative Thermochemical Measurements in High-Pressure Gaseous Combustion

    NASA Technical Reports Server (NTRS)

    Kojima, Jun J.; Fischer, David G.

    2012-01-01

    We present our strategic experiment and thermochemical analyses on combustion flow using a subframe burst gating (SBG) Raman spectroscopy. This unconventional laser diagnostic technique has promising ability to enhance accuracy of the quantitative scalar measurements in a point-wise single-shot fashion. In the presentation, we briefly describe an experimental methodology that generates transferable calibration standard for the routine implementation of the diagnostics in hydrocarbon flames. The diagnostic technology was applied to simultaneous measurements of temperature and chemical species in a swirl-stabilized turbulent flame with gaseous methane fuel at elevated pressure (17 atm). Statistical analyses of the space-/time-resolved thermochemical data provide insights into the nature of the mixing process and it impact on the subsequent combustion process in the model combustor.

  11. Regional cerebral blood flow measurement with intravenous ( sup 15 O)water bolus and ( sup 18 F)fluoromethane inhalation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Herholz, K.; Pietrzyk, U.; Wienhard, K.

    1989-09-01

    In 20 patients with ischemic cerebrovascular disease, classic migraine, or angiomas, we compared paired dynamic positron emission tomographic measurements of regional cerebral blood flow using both ({sup 15}O)water and ({sup 18}F)fluoromethane as tracers. Cerebral blood flow was also determined according to the autoradiographic technique with a bolus injection of ({sup 15}O)water. There were reasonable overall correlations between dynamic ({sup 15}O)water and ({sup 18}F)fluoromethane values for cerebral blood flow (r = 0.82) and between dynamic and autoradiographic ({sup 15}O)water values for cerebral blood flow (r = 0.83). We found a close correspondence between abnormal pathologic findings and visually evaluated cerebral bloodmore » flow tomograms obtained with the two tracers. On average, dynamic ({sup 15}O)water cerebral blood flow was 6% lower than that measured with ({sup 18}F)fluoromethane. There also was a general trend toward a greater underestimation with ({sup 15}O)water in high-flow areas, particularly in hyperemic areas, probably due to incomplete first-pass extraction of ({sup 15}O)water. Underestimation was not detected in low-flow areas or in the cerebellum. Absolute cerebral blood flow values were less closely correlated between tracers and techniques than cerebral blood flow patterns. The variability of the relation between absolute flow values was probably caused by confounding effects of the variation in the circulatory delay time. The autoradiographic technique was most sensitive to this type error.« less

  12. Quadratic elongation: A quantitative measure of distortion in coordination polyhedra

    USGS Publications Warehouse

    Robinson, Kelly F.; Gibbs, G.V.; Ribbe, P.H.

    1971-01-01

    Quadratic elongation and the variance of bond angles are linearly correlated for distorted octahedral and tetrahedral coordination complexes, both of which show variations in bond length and bond angle. The quadratic elonga tion is dimensionless, giving a quantitative measure of polyhedral distortion which is independent of the effective size of the polyhedron.

  13. Quantitative measures of healthy aging and biological age

    PubMed Central

    Kim, Sangkyu; Jazwinski, S. Michal

    2015-01-01

    Numerous genetic and non-genetic factors contribute to aging. To facilitate the study of these factors, various descriptors of biological aging, including ‘successful aging’ and ‘frailty’, have been put forth as integrative functional measures of aging. A separate but related quantitative approach is the ‘frailty index’, which has been operationalized and frequently used. Various frailty indices have been constructed. Although based on different numbers and types of health variables, frailty indices possess several common properties that make them useful across different studies. We have been using a frailty index termed FI34 based on 34 health variables. Like other frailty indices, FI34 increases non-linearly with advancing age and is a better indicator of biological aging than chronological age. FI34 has a substantial genetic basis. Using FI34, we found elevated levels of resting metabolic rate linked to declining health in nonagenarians. Using FI34 as a quantitative phenotype, we have also found a genomic region on chromosome 12 that is associated with healthy aging and longevity. PMID:26005669

  14. Quantitative fiber-optic Raman spectroscopy for tissue Raman measurements

    NASA Astrophysics Data System (ADS)

    Duraipandian, Shiyamala; Bergholt, Mads; Zheng, Wei; Huang, Zhiwei

    2014-03-01

    Molecular profiling of tissue using near-infrared (NIR) Raman spectroscopy has shown great promise for in vivo detection and prognostication of cancer. The Raman spectra measured from the tissue generally contain fundamental information about the absolute biomolecular concentrations in tissue and its changes associated with disease transformation. However, producing analogues tissue Raman spectra present a great technical challenge. In this preliminary study, we propose a method to ensure the reproducible tissue Raman measurements and validated with the in vivo Raman spectra (n=150) of inner lip acquired using different laser powers (i.e., 30 and 60 mW). A rapid Raman spectroscopy system coupled with a ball-lens fiber-optic Raman probe was utilized for tissue Raman measurements. The investigational results showed that the variations between the spectra measured with different laser powers are almost negligible, facilitating the quantitative analysis of tissue Raman measurements in vivo.

  15. Quantitative single-photon emission computed tomography/computed tomography for technetium pertechnetate thyroid uptake measurement

    PubMed Central

    Lee, Hyunjong; Kim, Ji Hyun; Kang, Yeon-koo; Moon, Jae Hoon; So, Young; Lee, Won Woo

    2016-01-01

    Abstract Objectives: Technetium pertechnetate (99mTcO4) is a radioactive tracer used to assess thyroid function by thyroid uptake system (TUS). However, the TUS often fails to deliver accurate measurements of the percent of thyroid uptake (%thyroid uptake) of 99mTcO4. Here, we investigated the usefulness of quantitative single-photon emission computed tomography/computed tomography (SPECT/CT) after injection of 99mTcO4 in detecting thyroid function abnormalities. Materials and methods: We retrospectively reviewed data from 50 patients (male:female = 15:35; age, 46.2 ± 16.3 years; 17 Graves disease, 13 thyroiditis, and 20 euthyroid). All patients underwent 99mTcO4 quantitative SPECT/CT (185 MBq = 5 mCi), which yielded %thyroid uptake and standardized uptake value (SUV). Twenty-one (10 Graves disease and 11 thyroiditis) of the 50 patients also underwent conventional %thyroid uptake measurements using a TUS. Results: Quantitative SPECT/CT parameters (%thyroid uptake, SUVmean, and SUVmax) were the highest in Graves disease, second highest in euthyroid, and lowest in thyroiditis (P < 0.0001, Kruskal–Wallis test). TUS significantly overestimated the %thyroid uptake compared with SPECT/CT (P < 0.0001, paired t test) because other 99mTcO4 sources in addition to thyroid, such as salivary glands and saliva, contributed to the %thyroid uptake result by TUS, whereas %thyroid uptake, SUVmean and SUVmax from the SPECT/CT were associated with the functional status of thyroid. Conclusions: Quantitative SPECT/CT is more accurate than conventional TUS for measuring 99mTcO4 %thyroid uptake. Quantitative measurements using SPECT/CT may facilitate more accurate assessment of thyroid tracer uptake. PMID:27399139

  16. Autoradiographic localization of specific (/sup 3/H)dexamethasone binding in fetal lung

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beer, D.G.; Butley, M.S.; Cunha, G.R.

    1984-10-01

    The cellular and subcellular localization of specific (/sup 3/H)dexamethasone binding was examined in fetal mouse lung at various stages of development and in human fetal lung at 8 weeks of gestation using a rapid in vitro steroid incubation technique followed by thaw-mount autoradiography. Competition studies with unlabeled steroids demonstrate the specificity of (/sup 3/H)dexamethasone labeling, and indicate that fetal lung mesenchyme is a primary glucocorticoid target during lung development. Autoradiographs of (/sup 3/H)dexamethasone binding in lung tissue at early stages of development demonstrate that the mesenchyme directly adjacent to the more proximal portions of the bronchiolar network is heavily labeled.more » In contrast, the epithelium which will later differentiate into bronchi and bronchioles, is relatively unlabeled. Distal portions of the growing epithelium, destined to become alveolar ducts and alveoli, do show nuclear localization of (/sup 3/H)dexamethasone. In addition, by utilizing a technique which allows the simultaneous examination of extracellular matrix components and (/sup 3/H)dexamethasone binding, a relationship is observed between extensive mesenchymal (/sup 3/H)dexamethasone binding and extensive extracellular matrix accumulation. Since glucocorticoids stimulate the synthesis of many extracellular matrix components, these results suggest a role for these hormones in affecting mesenchymal-epithelial interactions during lung morphogenesis.« less

  17. Refractive index variance of cells and tissues measured by quantitative phase imaging.

    PubMed

    Shan, Mingguang; Kandel, Mikhail E; Popescu, Gabriel

    2017-01-23

    The refractive index distribution of cells and tissues governs their interaction with light and can report on morphological modifications associated with disease. Through intensity-based measurements, refractive index information can be extracted only via scattering models that approximate light propagation. As a result, current knowledge of refractive index distributions across various tissues and cell types remains limited. Here we use quantitative phase imaging and the statistical dispersion relation (SDR) to extract information about the refractive index variance in a variety of specimens. Due to the phase-resolved measurement in three-dimensions, our approach yields refractive index results without prior knowledge about the tissue thickness. With the recent progress in quantitative phase imaging systems, we anticipate that using SDR will become routine in assessing tissue optical properties.

  18. Calcium in pollen-pistil interaction in Petunia hybrida Hort. I. Localization of Ca2+ ions in mature pollen grain using pyroantimonate and autoradiographic methods.

    PubMed

    Bednarska, E; Butowt, R

    1994-01-01

    The localization of Ca2+ in the mature pollen grain and the flow of these ions from the somatic tissues of the anther to the pollen grains has been studied using pyroantimonate and autoradiographic methods. In the pollen grain, Ca2+ ions have been localized in the sporoderm and in the cytoplasmic vesicles of probably dictyosomal origin. Calcium ions were transported into the sporoderm together with the compounds of degenerating tapetum. The material of degenerating tapetum forms pollen coat surrounding the mature pollen grain.

  19. Quantitative Measurement of Oxygen in Microgravity Combustion

    NASA Technical Reports Server (NTRS)

    Silver, Joel A.

    1997-01-01

    A low-gravity environment, in space or in ground-based facilities such as drop towers, provides a unique setting for studying combustion mechanisms. Understanding the physical phenomena controlling the ignition and spread of flames in microgravity has importance for space safety as well as for better characterization of dynamical and chemical combustion processes which are normally masked by buoyancy and other gravity-related effects. Due to restrictions associated with performing measurements in reduced gravity, diagnostic methods which have been applied to microgravity combustion studies have generally been limited to capture of flame emissions on film or video, laser Schlieren imaging and (intrusive) temperature measurements using thermocouples. Given the development of detailed theoretical models, more sophisticated diagnostic methods are needed to provide the kind of quantitative data necessary to characterize the properties of microgravity combustion processes as well as provide accurate feedback to improve the predictive capabilities of the models. When the demands of space flight are considered, the need for improved diagnostic systems which are rugged, compact, reliable, and operate at low power becomes apparent. The objective of this research is twofold. First, we want to develop a better understanding of the relative roles of diffusion and reaction of oxygen in microgravity combustion. As the primary oxidizer species, oxygen plays a major role in controlling the observed properties of flames, including flame front speed (in solid or liquid flames), extinguishment characteristics, flame size and flame temperature. The second objective is to develop better diagnostics based on diode laser absorption which can be of real value in both microgravity combustion research and as a sensor on-board Spacelab as either an air quality monitor or as part of a fire detection system. In our prior microgravity work, an eight line-of-sight fiber optic system measured

  20. NASA Intellectual Property Negotiation Practices and their Relationship to Quantitative Measures of Technology Transfer

    NASA Technical Reports Server (NTRS)

    Bush, Lance B.

    1997-01-01

    In the current political climate NASA must be able to show reliable measures demonstrating successful technology transfer. The currently available quantitative data of intellectual property technology transfer efforts portray a less than successful performance. In this paper, the use of only quantitative values for measurement of technology transfer is shown to undervalue the effort. In addition, NASA's current policy in negotiating intellectual property rights results in undervalued royalty rates. NASA has maintained that it's position of providing public good precludes it from negotiating fair market value for its technology and instead has negotiated for reasonable cost in order to recover processing fees. This measurement issue is examined and recommendations made which include a new policy regarding the intellectual property rights negotiation, and two measures to supplement the intellectual property measures.

  1. Development of a novel nanoscratch technique for quantitative measurement of ice adhesion strength

    NASA Astrophysics Data System (ADS)

    Loho, T.; Dickinson, M.

    2018-04-01

    The mechanism for the way that ice adheres to surfaces is still not well understood. Currently there is no standard method to quantitatively measure how ice adheres to surfaces which makes ice surface studies difficult to compare. A novel quantitative lateral force adhesion measurement at the micro-nano scale for ice was created which shears micro-nano sized ice droplets (less than 3 μm in diameter and 100nm in height) using a nanoindenter. By using small ice droplets, the variables associated with bulk ice measurements were minimised which increased data repeatability compared to bulk testing. The technique provided post- testing surface scans to confirm that the ice had been removed and that measurements were of ice adhesion strength. Results show that the ice adhesion strength of a material is greatly affected by the nano-scale surface roughness of the material with rougher surfaces having higher ice adhesion strength.

  2. C14 Assays and Autoradiographic Studies on the Rooster Comb

    PubMed Central

    Balazs, Endre A.; Szirmai, John A.; Bergendahl, Gudrun

    1959-01-01

    The distribution of C14 was studied in various parts of the rooster comb following treatment with testosterone. The value of gas-phase assay of C14 in tissue has been demonstrated and the results compared with those of autoradiographic studies on the same tissue. The results of these experiments showed that androgen treatment significantly increases the rate of incorporation of C14 in various parts of the comb. The specific activity of carbon in the comb, cornea, and liver differed, depending on which precursor, viz. glucose-6-C14, glucose-1-C14, and glucuronolactone-U-C14, was administered. The highest values were obtained after the administration of glucose-6-C14; glucuronolactone-U-C14 gave the lowest specific activity. The specific activity of carbon in different parts of the comb showed considerable variation. Carbon assay of serial sections of the comb cut at various planes showed that the specific activity of carbon was highest in the mucoid layer. Both C14 assays and autoradiograms indicate that C14 is also present in other parts of the comb. As seen in autoradiography, the concentration of C14 was highest in the epithelium, in the blood vessel walls, and in the avascular collagenous tissue. These results, and indications from previous studies, suggest that the high specific activity of carbon in the mucoid layer is due mainly to the presence of C14-labelled hyaluronic acid. Autoradiograms and PAS staining suggest that a significant amount of C14 is also incorporated into the glycoproteins associated with the collagen fibers. PMID:13654453

  3. How quantitative measures unravel design principles in multi-stage phosphorylation cascades.

    PubMed

    Frey, Simone; Millat, Thomas; Hohmann, Stefan; Wolkenhauer, Olaf

    2008-09-07

    We investigate design principles of linear multi-stage phosphorylation cascades by using quantitative measures for signaling time, signal duration and signal amplitude. We compare alternative pathway structures by varying the number of phosphorylations and the length of the cascade. We show that a model for a weakly activated pathway does not reflect the biological context well, unless it is restricted to certain parameter combinations. Focusing therefore on a more general model, we compare alternative structures with respect to a multivariate optimization criterion. We test the hypothesis that the structure of a linear multi-stage phosphorylation cascade is the result of an optimization process aiming for a fast response, defined by the minimum of the product of signaling time and signal duration. It is then shown that certain pathway structures minimize this criterion. Several popular models of MAPK cascades form the basis of our study. These models represent different levels of approximation, which we compare and discuss with respect to the quantitative measures.

  4. Quantitative elasticity measurement of urinary bladder wall using laser-induced surface acoustic waves.

    PubMed

    Li, Chunhui; Guan, Guangying; Zhang, Fan; Song, Shaozhen; Wang, Ruikang K; Huang, Zhihong; Nabi, Ghulam

    2014-12-01

    The maintenance of urinary bladder elasticity is essential to its functions, including the storage and voiding phases of the micturition cycle. The bladder stiffness can be changed by various pathophysiological conditions. Quantitative measurement of bladder elasticity is an essential step toward understanding various urinary bladder disease processes and improving patient care. As a nondestructive, and noncontact method, laser-induced surface acoustic waves (SAWs) can accurately characterize the elastic properties of different layers of organs such as the urinary bladder. This initial investigation evaluates the feasibility of a noncontact, all-optical method of generating and measuring the elasticity of the urinary bladder. Quantitative elasticity measurements of ex vivo porcine urinary bladder were made using the laser-induced SAW technique. A pulsed laser was used to excite SAWs that propagated on the bladder wall surface. A dedicated phase-sensitive optical coherence tomography (PhS-OCT) system remotely recorded the SAWs, from which the elasticity properties of different layers of the bladder were estimated. During the experiments, series of measurements were performed under five precisely controlled bladder volumes using water to estimate changes in the elasticity in relation to various urinary bladder contents. The results, validated by optical coherence elastography, show that the laser-induced SAW technique combined with PhS-OCT can be a feasible method of quantitative estimation of biomechanical properties.

  5. Impact of image quality on OCT angiography based quantitative measurements.

    PubMed

    Al-Sheikh, Mayss; Ghasemi Falavarjani, Khalil; Akil, Handan; Sadda, SriniVas R

    2017-01-01

    To study the impact of image quality on quantitative measurements and the frequency of segmentation error with optical coherence tomography angiography (OCTA). Seventeen eyes of 10 healthy individuals were included in this study. OCTA was performed using a swept-source device (Triton, Topcon). Each subject underwent three scanning sessions 1-2 min apart; the first two scans were obtained under standard conditions and for the third session, the image quality index was reduced using application of a topical ointment. En face OCTA images of the retinal vasculature were generated using the default segmentation for the superficial and deep retinal layer (SRL, DRL). Intraclass correlation coefficient (ICC) was used as a measure for repeatability. The frequency of segmentation error, motion artifact, banding artifact and projection artifact was also compared among the three sessions. The frequency of segmentation error, and motion artifact was statistically similar between high and low image quality sessions (P = 0.707, and P = 1 respectively). However, the frequency of projection and banding artifact was higher with a lower image quality. The vessel density in the SRL was highly repeatable in the high image quality sessions (ICC = 0.8), however, the repeatability was low, comparing the high and low image quality measurements (ICC = 0.3). In the DRL, the repeatability of the vessel density measurements was fair in the high quality sessions (ICC = 0.6 and ICC = 0.5, with and without automatic artifact removal, respectively) and poor comparing high and low image quality sessions (ICC = 0.3 and ICC = 0.06, with and without automatic artifact removal, respectively). The frequency of artifacts is higher and the repeatability of the measurements is lower with lower image quality. The impact of image quality index should be always considered in OCTA based quantitative measurements.

  6. Single-case synthesis tools II: Comparing quantitative outcome measures.

    PubMed

    Zimmerman, Kathleen N; Pustejovsky, James E; Ledford, Jennifer R; Barton, Erin E; Severini, Katherine E; Lloyd, Blair P

    2018-03-07

    Varying methods for evaluating the outcomes of single case research designs (SCD) are currently used in reviews and meta-analyses of interventions. Quantitative effect size measures are often presented alongside visual analysis conclusions. Six measures across two classes-overlap measures (percentage non-overlapping data, improvement rate difference, and Tau) and parametric within-case effect sizes (standardized mean difference and log response ratio [increasing and decreasing])-were compared to determine if choice of synthesis method within and across classes impacts conclusions regarding effectiveness. The effectiveness of sensory-based interventions (SBI), a commonly used class of treatments for young children, was evaluated. Separately from evaluations of rigor and quality, authors evaluated behavior change between baseline and SBI conditions. SBI were unlikely to result in positive behavior change across all measures except IRD. However, subgroup analyses resulted in variable conclusions, indicating that the choice of measures for SCD meta-analyses can impact conclusions. Suggestions for using the log response ratio in SCD meta-analyses and considerations for understanding variability in SCD meta-analysis conclusions are discussed. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Quantitative magnetic resonance (QMR) measurement of changes in body composition of neonatal pigs

    USDA-ARS?s Scientific Manuscript database

    The survival of low birth weight pigs in particular may depend on energy stores in the body. QMR (quantitative magnetic resonance) is a new approach to measuring total body fat, lean and water. These measurements are based on quantifying protons associated with lipid and water molecules in the body...

  8. Issues to Consider When Measuring and Applying Socioeconomic Position Quantitatively in Immigrant Health Research

    PubMed Central

    Nielsen, Signe Smith; Hempler, Nana Folmann; Krasnik, Allan

    2013-01-01

    The relationship between migration and health is complex, yet, immigrant-related inequalities in health are largely influenced by socioeconomic position. Drawing upon previous findings, this paper discusses issues to consider when measuring and applying socioeconomic position in quantitative immigrant health research. When measuring socioeconomic position, it is important to be aware of four aspects: (1) there is a lack of clarity about how socioeconomic position should be measured; (2) different types of socioeconomic position may be relevant to immigrants compared with the native-born population; (3) choices of measures of socioeconomic position in quantitative analyses often rely on data availability; and (4) different measures of socioeconomic position have different effects in population groups. Therefore, caution should be used in the collection, presentation, analyses, and interpretation of data and researchers need to display their proposed conceptual models and data limitations as well as apply different approaches for analyses. PMID:24287857

  9. Effects of methylmercury on muscarinic receptors in the mouse brain: A quantitative autoradiographic study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Haesung; Yee, S.; Geddes, J.

    1991-03-11

    Methylmercury (MeHg) is reported to inhibit several stages of cholinergic neurotransmission in brain tissue in-vitro and in-vivo. To examine whether or not behavioral disturbances and/or selective vulnerability of specific neuronal groups in MeHg poisoning may be related to MeHg effects on cholinergic receptors in specific regions of the brain, the density and distribution of muscarinic receptors in the brains of C57BL/6J mice were determined following repeated injections of 5 mg/kg of methylmercuric chloride (MMC). The receptor densities in six cortical laminae of seven cerebral cortical regions, hippocampus and striatum were quantitated by computer-assisted imaging system following in-vitro labeling with ({supmore » 3}H)-pirenzepine (M1) and ({sup 3}H)N-methyl scopolamine (M2). The results showed heterogeneous distribution of M1 and M2 sites in different regions of the brain, and significant reduction in the density of both receptor subtypes following MeHg poisoning in many cortical and subcortical regions. However, the changes in the density were variable in different laminae even in the same cortical regions. Prominent reductions in M1 densities were noted in the temporal and entorhinal cortices, CA3 and hilar regions of the hippocampus as compared to control, whereas the reduction in M2 receptor density was most prominently noted in the frontal, perirhinal and entorhinal cortices, and CA1 and hilar regions of the hippocampus. Thus, it is apparent that MeHg significantly affects muscarinic receptors in the mouse brain, and that these data when used in conjunction with immunocytochemical and other morphological studies would provide further insights into the mechanisms of neurotoxic effects of MeHg.« less

  10. Quantitative Measurements of Nitric Oxide Concentration in High-Pressure, Swirl-Stabilized Spray Flames

    NASA Technical Reports Server (NTRS)

    Cooper, Clayton S.; Laurendeau, Normand M.; Hicks, Yolanda R. (Technical Monitor)

    2000-01-01

    Lean direct-injection (LDI) spray flames offer the possibility of reducing NO(sub x) emissions from gas turbines by rapid mixing of the liquid fuel and air so as to drive the flame structure toward partially-premixed conditions. We consider the technical approaches required to utilize laser-induced fluorescence methods for quantitatively measuring NO concentrations in high-pressure LDI spray flames. In the progression from atmospheric to high-pressure measurements, the LIF method requires a shift from the saturated to the linear regime of fluorescence measurements. As such, we discuss quantitative, spatially resolved laser-saturated fluorescence (LSF), linear laser-induced fluorescence (LIF), and planar laser-induced fluorescence (PLIF) measurements of NO concentration in LDI spray flames. Spatially-resolved LIF measurements of NO concentration (ppm) are reported for preheated, LDI spray flames at pressures of two to five atmospheres. The spray is produced by a hollow-cone, pressure-atomized nozzle supplied with liquid heptane. NO is excited via the Q(sub 2)(26.5) transition of the gamma(0,0) band. Detection is performed in a two nanometer region centered on the gamma(0,1) band. A complete scheme is developed by which quantitative NO concentrations in high-pressure LDI spray flames can be measured by applying linear LIF. NO is doped into the reactants and convected through the flame with no apparent destruction, thus allowing a NO fluorescence calibration to be taken inside the flame environment. The in-situ calibration scheme is validated by comparisons to a reference flame. Quantitative NO profiles are presented and analyzed so as to better understand the operation of lean-direct injectors for gas turbine combustors. Moreover, parametric studies are provided for variations in pressure, air-preheat temperature, and equivalence ratio. Similar parametric studies are performed for lean, premixed-prevaporized flames to permit comparisons to those for LDI flames

  11. Quantitative stress measurement of elastic deformation using mechanoluminescent sensor: An intensity ratio model

    NASA Astrophysics Data System (ADS)

    Cai, Tao; Guo, Songtao; Li, Yongzeng; Peng, Di; Zhao, Xiaofeng; Liu, Yingzheng

    2018-04-01

    The mechanoluminescent (ML) sensor is a newly developed non-invasive technique for stress/strain measurement. However, its application has been mostly restricted to qualitative measurement due to the lack of a well-defined relationship between ML intensity and stress. To achieve accurate stress measurement, an intensity ratio model was proposed in this study to establish a quantitative relationship between the stress condition and its ML intensity in elastic deformation. To verify the proposed model, experiments were carried out on a ML measurement system using resin samples mixed with the sensor material SrAl2O4:Eu2+, Dy3+. The ML intensity ratio was found to be dependent on the applied stress and strain rate, and the relationship acquired from the experimental results agreed well with the proposed model. The current study provided a physical explanation for the relationship between ML intensity and its stress condition. The proposed model was applicable in various SrAl2O4:Eu2+, Dy3+-based ML measurement in elastic deformation, and could provide a useful reference for quantitative stress measurement using the ML sensor in general.

  12. Qualitative pattern classification of shear wave elastography for breast masses: how it correlates to quantitative measurements.

    PubMed

    Yoon, Jung Hyun; Ko, Kyung Hee; Jung, Hae Kyoung; Lee, Jong Tae

    2013-12-01

    To determine the correlation of qualitative shear wave elastography (SWE) pattern classification to quantitative SWE measurements and whether it is representative of quantitative SWE values with similar performances. From October 2012 to January 2013, 267 breast masses of 236 women (mean age: 45.12 ± 10.54 years, range: 21-88 years) who had undergone ultrasonography (US), SWE, and subsequent biopsy were included. US BI-RADS final assessment and qualitative and quantitative SWE measurements were recorded. Correlation between pattern classification and mean elasticity, maximum elasticity, elasticity ratio and standard deviation were evaluated. Diagnostic performances of grayscale US, SWE parameters, and US combined to SWE values were calculated and compared. Of the 267 breast masses, 208 (77.9%) were benign and 59 (22.1%) were malignant. Pattern classifications significantly correlated with all quantitative SWE measurements, showing highest correlation with maximum elasticity, r = 0.721 (P<0.001). Sensitivity was significantly decreased in US combined to SWE measurements to grayscale US: 69.5-89.8% to 100.0%, while specificity was significantly improved: 62.5-81.7% to 13.9% (P<0.001). Area under the ROC curve (Az) did not show significant differences between grayscale US to US combined to SWE (P>0.05). Pattern classification shows high correlation to maximum stiffness and may be representative of quantitative SWE values. When combined to grayscale US, SWE improves specificity of US. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  13. Tophaceous gout: quantitative evaluation by direct physical measurement.

    PubMed

    Schumacher, H Ralph; Becker, Michael A; Palo, William A; Streit, Janet; MacDonald, Patricia A; Joseph-Ridge, Nancy

    2005-12-01

    The absence of accepted standardized methods for monitoring tophaceous gout limits the ability to track tophus progression or regression. This multicenter study assessed intra- and interrater reproducibility of a simple and direct physical measurement. The quantitative evaluation was the area (mm2) of each measurable tophus and was determined independently by 2 raters on 2 occasions within 10 days. Intra- and interrater reproducibilities were determined by calculating mean differences and average percentage differences (APD) in measurements of areas for the same tophus at each of 2 visits and by each rater, respectively. Fifty-two tophi were measured in 13 subjects: 22 on the hand/wrist, 16 on the elbow, and 14 on the foot/ankle. The mean (+/- SD) difference in tophus areas between visits was -0.2 +/- 835 mm2 (95% CI -162 to 162 mm2) and the mean (+/- SD) APD was 29% +/- 33%. The mean (+/- SD) APD between raters was 32% +/- 27%. The largest variations in measurements were noted for elbow tophi and variations were least for well demarcated tophi on the hands. This simple and reproducible method can be easily utilized in clinical trials and in practice as a measure of efficacy of urate-lowering treatment in tophaceous gout. Among factors contributing to variability in these measurements were the anatomic site of tophi and rater experience with the method. Restriction of measurements to well circumscribed hand or foot tophi could improve reliability, but major changes, as expected with effective therapy, can clearly be documented with this simple technique.

  14. Quantitative measurement of oxygen in microgravity combustion

    NASA Technical Reports Server (NTRS)

    Silver, Joel A.

    1995-01-01

    This research combines two innovations in an experimental system which should result in a new capability for quantitative, nonintrusive measurement of major combustion species. Using a newly available vertical cavity surface-emitting diode laser (VCSEL) and an improved spatial scanning method, we plan to measure the temporal and spatial profiles of the concentrations and temperatures of molecular oxygen in a candle flame and in a solid fuel (cellulose sheet) system. The required sensitivity for detecting oxygen is achieved by the use of high frequency wavelength modulation spectroscopy (WMS). Measurements will be performed in the NASA Lewis 2.2-second Drop Tower Facility. The objective of this research is twofold. First, we want to develop a better understanding of the relative roles of diffusion and reaction of oxygen in microgravity combustion. As the primary oxidizer species, oxygen plays a major role in controlling the observed properties of flames, including flame front speed (in solid or liquid flames), extinguishment characteristics, flame size, and flame temperature. The second objective is to develop better diagnostics based on diode laser absorption which can be of real value in microgravity combustion research. We will also demonstrate diode lasers' potential usefulness for compact, intrinsically-safe monitoring sensors aboard spacecraft. Such sensors could be used to monitor any of the major cabin gases as well as important pollutants.

  15. AUTORADIOGRAPHIC LOCALIZATION OF 13N AFTER FIXATION OF 13N-LABELED NITROGEN GAS BY A HETEROCYST-FORMING BLUE-GREEN ALGA

    PubMed Central

    Wolk, C. Peter; Austin, Sam M.; Bortins, John; Galonsky, Aaron

    1974-01-01

    13N, generated by proton bombardment of 13C powder, is rapidly and easily converted to 13N-N2, 0.01 atm pressure, ca. 10 mCi/ml, by automated Dumas combustion. 13N fixed (as 13N-N2) by algal filaments was localized by an autoradiographic technique which permits track autoradiography with isotopes having short half-lives. Our findings show directly that a minimum of about 25% of the N2 fixation by intact, aerobically grown filaments of Anabaena cylindrica is carried out by the heterocysts. If all of the N2 fixation takes place in the heterocysts, then the movement of nitrogen along the filaments can be characterized by a constant τ < ca. 5 s (cell-2). PMID:4208073

  16. Quantitative CT Measures of Bronchiectasis in Smokers.

    PubMed

    Diaz, Alejandro A; Young, Thomas P; Maselli, Diego J; Martinez, Carlos H; Gill, Ritu; Nardelli, Pietro; Wang, Wei; Kinney, Gregory L; Hokanson, John E; Washko, George R; San Jose Estepar, Raul

    2017-06-01

    Bronchiectasis is frequent in smokers with COPD; however, there are only limited data on objective assessments of this process. The objective was to assess bronchovascular morphology, calculate the ratio of the diameters of bronchial lumen and adjacent artery (BA ratio), and identify those measurements able to discriminate bronchiectasis. We collected quantitative CT (QCT) measures of BA ratios, peak wall attenuation, wall thickness (WT), wall area, and wall area percent (WA%) at matched fourth through sixth airway generations in 21 ever smokers with bronchiectasis (cases) and 21 never-smoking control patients (control airways). In cases, measurements were collected at both bronchiectatic and nonbronchiectatic airways. Logistic analysis and the area under receiver operating characteristic curve (AUC) were used to assess the predictive ability of QCT measurements for bronchiectasis. The whole-lung and fourth through sixth airway generation BA ratio, WT, and WA% were significantly greater in bronchiectasis cases than control patients. The AUCs for the BA ratio to predict bronchiectasis ranged from 0.90 (whole lung) to 0.79 (fourth-generation). AUCs for WT and WA% ranged from 0.72 to 0.75 and from 0.71 to 0.75. The artery diameters but not bronchial diameters were smaller in bronchiectatic than both nonbronchiectatic and control airways (P < .01 for both). Smoking-related increases in the BA ratio appear to be driven by reductions in vascular caliber. QCT measures of BA ratio, WT, and WA% may be useful to objectively identify and quantify bronchiectasis in smokers. ClinicalTrials.gov; No.: NCT00608764; URL: www.clinicaltrials.gov. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  17. Quantitative measurement of regional blood flow with gadolinium diethylenetriaminepentaacetate bolus track NMR imaging in cerebral infarcts in rats: validation with the iodo[14C]antipyrine technique.

    PubMed Central

    Wittlich, F; Kohno, K; Mies, G; Norris, D G; Hoehn-Berlage, M

    1995-01-01

    NMR bolus track measurements were correlated with autoradiographically determined regional cerebral blood flow (rCBF). The NMR method is based on bolus infusion of the contrast agent gadolinium diethylenetriaminepentaacetate and high-speed T*2-sensitive NMR imaging. The first pass of the contrast agent through the image plane causes a transient decrease of the signal intensity. This time course of the signal intensity is transformed into relative concentrations of the contrast agent in each pixel. The mean transit time and relative blood flow and volume are calculated from such indicator dilution curves. We investigated whether this NMR technique correctly expresses the relative rCBF. The relative blood flow data, calculated from NMR bolus track experiments, and the absolute values of iodo[14C]antipyrine autoradiography were compared. A linear relationship was observed, indicating the proportionality of the transient NMR signal change with CBF. Excellent interindividual reproducibility of calibration constants is observed (r = 0.963). For a given NMR protocol, bolus track measurements calibrated with autoradiography after the experiment allow determination of absolute values for rCBF and regional blood volume. Images Fig. 2 Fig. 3 PMID:7892189

  18. Quantitative measures of gingival recession and the influence of gender, race, and attrition.

    PubMed

    Handelman, Chester S; Eltink, Anthony P; BeGole, Ellen

    2018-01-29

    Gingival recession in dentitions with otherwise healthy periodontium is a common occurrence in adults. Recession is clinically measured using a periodontal probe to the nearest millimeter. The aim of this study is to establish quantitative measures of recession, the clinical crown height, and a new measure the gingival margin-papillae measurement. The latter is seen as the shortest apico-coronal distance measured from the depth of the gingival margin to a line connecting the tips of the two adjacent papillae. Measurements on all teeth up to and including the first molar were performed on pretreatment study models of 120 adult Caucasian and African-American subjects divided into four groups of 30 by gender and race. Both the clinical crown height and the gingival margin-papillae measurements gave a true positive result for changes associated with gingival recession. Tooth wear shortens the clinical crown, and therefore, the measure of clinical crown height can give a false negative result when gingival recession is present. However, the gingival margin-papillae measurement was not affected by tooth wear and gave a true positive result for gingival recession. Tooth wear (attrition) was not associated with an increase in gingival recession. These measures are also useful in detecting recession prior to cemental exposure. Measures for recession and tooth wear were different for the four demographic groups studied. These measures can be used as quantitative standards in both clinical dentistry, research, and epidemiological studies.

  19. Quantitative impedance measurements for eddy current model validation

    NASA Astrophysics Data System (ADS)

    Khan, T. A.; Nakagawa, N.

    2000-05-01

    This paper reports on a series of laboratory-based impedance measurement data, collected by the use of a quantitatively accurate, mechanically controlled measurement station. The purpose of the measurement is to validate a BEM-based eddy current model against experiment. We have therefore selected two "validation probes," which are both split-D differential probes. Their internal structures and dimensions are extracted from x-ray CT scan data, and thus known within the measurement tolerance. A series of measurements was carried out, using the validation probes and two Ti-6Al-4V block specimens, one containing two 1-mm long fatigue cracks, and the other containing six EDM notches of a range of sizes. Motor-controlled XY scanner performed raster scans over the cracks, with the probe riding on the surface with a spring-loaded mechanism to maintain the lift off. Both an impedance analyzer and a commercial EC instrument were used in the measurement. The probes were driven in both differential and single-coil modes for the specific purpose of model validation. The differential measurements were done exclusively by the eddyscope, while the single-coil data were taken with both the impedance analyzer and the eddyscope. From the single-coil measurements, we obtained the transfer function to translate the voltage output of the eddyscope into impedance values, and then used it to translate the differential measurement data into impedance results. The presentation will highlight the schematics of the measurement procedure, a representative of raw data, explanation of the post data-processing procedure, and then a series of resulting 2D flaw impedance results. A noise estimation will be given also, in order to quantify the accuracy of these measurements, and to be used in probability-of-detection estimation.—This work was supported by the NSF Industry/University Cooperative Research Program.

  20. Measuring iron in the brain using quantitative susceptibility mapping and X-ray fluorescence imaging

    PubMed Central

    Zheng, Weili; Nichol, Helen; Liu, Saifeng; Cheng, Yu-Chung N.; Haacke, E. Mark

    2013-01-01

    Measuring iron content in the brain has important implications for a number of neurodegenerative diseases. Quantitative susceptibility mapping (QSM), derived from magnetic resonance images, has been used to measure total iron content in vivo and in post mortem brain. In this paper, we show how magnetic susceptibility from QSM correlates with total iron content measured by X-ray fluorescence (XRF) imaging and by inductively coupled plasma mass spectrometry (ICPMS). The relationship between susceptibility and ferritin iron was estimated at 1.10 ± 0.08 ppb susceptibility per μg iron/g wet tissue, similar to that of iron in fixed (frozen/thawed) cadaveric brain and previously published data from unfixed brains. We conclude that magnetic susceptibility can provide a direct and reliable quantitative measurement of iron content and that it can be used clinically at least in regions with high iron content. PMID:23591072

  1. Measuring the Beginning: A Quantitative Study of the Transition to Higher Education

    ERIC Educational Resources Information Center

    Brooman, Simon; Darwent, Sue

    2014-01-01

    This quantitative study measures change in certain factors known to influence success of first-year students during the transition to higher education: self-efficacy, autonomous learning and social integration. A social integration scale was developed with three subscales: "sense of belonging", "relationship with staff" and…

  2. Technical note: quantitative measures of iris color using high resolution photographs.

    PubMed

    Edwards, Melissa; Gozdzik, Agnes; Ross, Kendra; Miles, Jon; Parra, Esteban J

    2012-01-01

    Our understanding of the genetic architecture of iris color is still limited. This is partly related to difficulties associated with obtaining quantitative measurements of eye color. Here we introduce a new automated method for measuring iris color using high resolution photographs. This method extracts color measurements in the CIE 1976 L*a*b* (CIELAB) color space from a 256 by 256 pixel square sampled from the 9:00 meridian of the iris. Color is defined across three dimensions: L* (the lightness coordinate), a* (the red-green coordinate), and b* (the blue-yellow coordinate). We applied this method to a sample of individuals of diverse ancestry (East Asian, European and South Asian) that was genotyped for the HERC2 rs12913832 polymorphism, which is strongly associated with blue eye color. We identified substantial variation in the CIELAB color space, not only in the European sample, but also in the East Asian and South Asian samples. As expected, rs12913832 was significantly associated with quantitative iris color measurements in subjects of European ancestry. However, this SNP was also strongly associated with iris color in the South Asian sample, although there were no participants with blue irides in this sample. The usefulness of this method is not restricted only to the study of iris pigmentation. High-resolution pictures of the iris will also make it possible to study the genetic variation involved in iris textural patterns, which show substantial heritability in human populations. Copyright © 2011 Wiley Periodicals, Inc.

  3. Practicable methods for histological section thickness measurement in quantitative stereological analyses.

    PubMed

    Matenaers, Cyrill; Popper, Bastian; Rieger, Alexandra; Wanke, Rüdiger; Blutke, Andreas

    2018-01-01

    The accuracy of quantitative stereological analysis tools such as the (physical) disector method substantially depends on the precise determination of the thickness of the analyzed histological sections. One conventional method for measurement of histological section thickness is to re-embed the section of interest vertically to its original section plane. The section thickness is then measured in a subsequently prepared histological section of this orthogonally re-embedded sample. However, the orthogonal re-embedding (ORE) technique is quite work- and time-intensive and may produce inaccurate section thickness measurement values due to unintentional slightly oblique (non-orthogonal) positioning of the re-embedded sample-section. Here, an improved ORE method is presented, allowing for determination of the factual section plane angle of the re-embedded section, and correction of measured section thickness values for oblique (non-orthogonal) sectioning. For this, the analyzed section is mounted flat on a foil of known thickness (calibration foil) and both the section and the calibration foil are then vertically (re-)embedded. The section angle of the re-embedded section is then calculated from the deviation of the measured section thickness of the calibration foil and its factual thickness, using basic geometry. To find a practicable, fast, and accurate alternative to ORE, the suitability of spectral reflectance (SR) measurement for determination of plastic section thicknesses was evaluated. Using a commercially available optical reflectometer (F20, Filmetrics®, USA), the thicknesses of 0.5 μm thick semi-thin Epon (glycid ether)-sections and of 1-3 μm thick plastic sections (glycolmethacrylate/ methylmethacrylate, GMA/MMA), as regularly used in physical disector analyses, could precisely be measured within few seconds. Compared to the measured section thicknesses determined by ORE, SR measures displayed less than 1% deviation. Our results prove the applicability

  4. Practicable methods for histological section thickness measurement in quantitative stereological analyses

    PubMed Central

    Matenaers, Cyrill; Popper, Bastian; Rieger, Alexandra; Wanke, Rüdiger

    2018-01-01

    The accuracy of quantitative stereological analysis tools such as the (physical) disector method substantially depends on the precise determination of the thickness of the analyzed histological sections. One conventional method for measurement of histological section thickness is to re-embed the section of interest vertically to its original section plane. The section thickness is then measured in a subsequently prepared histological section of this orthogonally re-embedded sample. However, the orthogonal re-embedding (ORE) technique is quite work- and time-intensive and may produce inaccurate section thickness measurement values due to unintentional slightly oblique (non-orthogonal) positioning of the re-embedded sample-section. Here, an improved ORE method is presented, allowing for determination of the factual section plane angle of the re-embedded section, and correction of measured section thickness values for oblique (non-orthogonal) sectioning. For this, the analyzed section is mounted flat on a foil of known thickness (calibration foil) and both the section and the calibration foil are then vertically (re-)embedded. The section angle of the re-embedded section is then calculated from the deviation of the measured section thickness of the calibration foil and its factual thickness, using basic geometry. To find a practicable, fast, and accurate alternative to ORE, the suitability of spectral reflectance (SR) measurement for determination of plastic section thicknesses was evaluated. Using a commercially available optical reflectometer (F20, Filmetrics®, USA), the thicknesses of 0.5 μm thick semi-thin Epon (glycid ether)-sections and of 1–3 μm thick plastic sections (glycolmethacrylate/ methylmethacrylate, GMA/MMA), as regularly used in physical disector analyses, could precisely be measured within few seconds. Compared to the measured section thicknesses determined by ORE, SR measures displayed less than 1% deviation. Our results prove the applicability

  5. Influence of residual oxygen-15-labeled carbon monoxide radioactivity on cerebral blood flow and oxygen extraction fraction in a dual-tracer autoradiographic method.

    PubMed

    Iwanishi, Katsuhiro; Watabe, Hiroshi; Hayashi, Takuya; Miyake, Yoshinori; Minato, Kotaro; Iida, Hidehiro

    2009-06-01

    Cerebral blood flow (CBF), cerebral metabolic rate of oxygen (CMRO(2)), oxygen extraction fraction (OEF), and cerebral blood volume (CBV) are quantitatively measured with PET with (15)O gases. Kudomi et al. developed a dual tracer autoradiographic (DARG) protocol that enables the duration of a PET study to be shortened by sequentially administrating (15)O(2) and C(15)O(2) gases. In this protocol, before the sequential PET scan with (15)O(2) and C(15)O(2) gases ((15)O(2)-C(15)O(2) PET scan), a PET scan with C(15)O should be preceded to obtain CBV image. C(15)O has a high affinity for red blood cells and a very slow washout rate, and residual radioactivity from C(15)O might exist during a (15)O(2)-C(15)O(2) PET scan. As the current DARG method assumes no residual C(15)O radioactivity before scanning, we performed computer simulations to evaluate the influence of the residual C(15)O radioactivity on the accuracy of measured CBF and OEF values with DARG method and also proposed a subtraction technique to minimize the error due to the residual C(15)O radioactivity. In the simulation, normal and ischemic conditions were considered. The (15)O(2) and C(15)O(2) PET count curves with the residual C(15)O PET counts were generated by the arterial input function with the residual C(15)O radioactivity. The amounts of residual C(15)O radioactivity were varied by changing the interval between the C(15)O PET scan and (15)O(2)-C(15)O(2) PET scan, and the absolute inhaled radioactivity of the C(15)O gas. Using the simulated input functions and the PET counts, the CBF and OEF were computed by the DARG method. Furthermore, we evaluated a subtraction method that subtracts the influence of the C(15)O gas in the input function and PET counts. Our simulations revealed that the CBF and OEF values were underestimated by the residual C(15)O radioactivity. The magnitude of this underestimation depended on the amount of C(15)O radioactivity and the physiological conditions. This underestimation

  6. Measurements of morphology and refractive indexes on human downy hairs using three-dimensional quantitative phase imaging.

    PubMed

    Lee, SangYun; Kim, Kyoohyun; Lee, Yuhyun; Park, Sungjin; Shin, Heejae; Yang, Jongwon; Ko, Kwanhong; Park, HyunJoo; Park, YongKeun

    2015-01-01

    We present optical measurements of morphology and refractive indexes (RIs) of human downy arm hairs using three-dimensional (3-D) quantitative phase imaging techniques. 3-D RI tomograms and high-resolution two-dimensional synthetic aperture images of individual downy arm hairs were measured using a Mach–Zehnder laser interferometric microscopy equipped with a two-axis galvanometer mirror. From the measured quantitative images, the RIs and morphological parameters of downy hairs were noninvasively quantified including the mean RI, volume, cylinder, and effective radius of individual hairs. In addition, the effects of hydrogen peroxide on individual downy hairs were investigated.

  7. Confirmatory Factor Analytic Structure and Measurement Invariance of Quantitative Autistic Traits Measured by the Social Responsiveness Scale-2

    ERIC Educational Resources Information Center

    Frazier, Thomas W.; Ratliff, Kristin R.; Gruber, Chris; Zhang, Yi; Law, Paul A.; Constantino, John N.

    2014-01-01

    Understanding the factor structure of autistic symptomatology is critical to the discovery and interpretation of causal mechanisms in autism spectrum disorder. We applied confirmatory factor analysis and assessment of measurement invariance to a large ("N" = 9635) accumulated collection of reports on quantitative autistic traits using…

  8. Comparing the MRI-based Goutallier Classification to an experimental quantitative MR spectroscopic fat measurement of the supraspinatus muscle.

    PubMed

    Gilbert, Fabian; Böhm, Dirk; Eden, Lars; Schmalzl, Jonas; Meffert, Rainer H; Köstler, Herbert; Weng, Andreas M; Ziegler, Dirk

    2016-08-22

    The Goutallier Classification is a semi quantitative classification system to determine the amount of fatty degeneration in rotator cuff muscles. Although initially proposed for axial computer tomography scans it is currently applied to magnet-resonance-imaging-scans. The role for its clinical use is controversial, as the reliability of the classification has been shown to be inconsistent. The purpose of this study was to compare the semi quantitative MRI-based Goutallier Classification applied by 5 different raters to experimental MR spectroscopic quantitative fat measurement in order to determine the correlation between this classification system and the true extent of fatty degeneration shown by spectroscopy. MRI-scans of 42 patients with rotator cuff tears were examined by 5 shoulder surgeons and were graduated according to the MRI-based Goutallier Classification proposed by Fuchs et al. Additionally the fat/water ratio was measured with MR spectroscopy using the experimental SPLASH technique. The semi quantitative grading according to the Goutallier Classification was statistically correlated with the quantitative measured fat/water ratio using Spearman's rank correlation. Statistical analysis of the data revealed only fair correlation of the Goutallier Classification system and the quantitative fat/water ratio with R = 0.35 (p < 0.05). By dichotomizing the scale the correlation was 0.72. The interobserver and intraobserver reliabilities were substantial with R = 0.62 and R = 0.74 (p < 0.01). The correlation between the semi quantitative MRI based Goutallier Classification system and MR spectroscopic fat measurement is weak. As an adequate estimation of fatty degeneration based on standard MRI may not be possible, quantitative methods need to be considered in order to increase diagnostic safety and thus provide patients with ideal care in regard to the amount of fatty degeneration. Spectroscopic MR measurement may increase the accuracy of

  9. Quantitative nuclear magnetic resonance to measure body composition in infants and children

    USDA-ARS?s Scientific Manuscript database

    Quantitative Nuclear Magnetic Resonance (QMR) is being used in human adults to obtain measures of total body fat (FM) with high precision. The current study assessed a device specially designed to accommodate infants and children between 3 and 50 kg (EchoMRI-AH™). Body composition of 113 infants and...

  10. Quantitative measurements of electromechanical response with a combined optical beam and interferometric atomic force microscope

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Labuda, Aleksander; Proksch, Roger

    An ongoing challenge in atomic force microscope (AFM) experiments is the quantitative measurement of cantilever motion. The vast majority of AFMs use the optical beam deflection (OBD) method to infer the deflection of the cantilever. The OBD method is easy to implement, has impressive noise performance, and tends to be mechanically robust. However, it represents an indirect measurement of the cantilever displacement, since it is fundamentally an angular rather than a displacement measurement. Here, we demonstrate a metrological AFM that combines an OBD sensor with a laser Doppler vibrometer (LDV) to enable accurate measurements of the cantilever velocity and displacement.more » The OBD/LDV AFM allows a host of quantitative measurements to be performed, including in-situ measurements of cantilever oscillation modes in piezoresponse force microscopy. As an example application, we demonstrate how this instrument can be used for accurate quantification of piezoelectric sensitivity—a longstanding goal in the electromechanical community.« less

  11. Autoradiographic identification of acetylcholine in the rabbit retina

    PubMed Central

    1979-01-01

    Rabbit retinas were studied in vitro under conditions known to maintain their physiological function. Retinas incubated in the presence of [3H]choline synthesized substantial amounts of both [3H]phosphorylcholine and [3H]acetylcholine. With time, [3H]phosphorylcholine proceeded into phospholipids, primarily phosphatidylcholine. Retinas pulse-labeled by a 15-min exposure to 0.3 microM [3H]choline were incubated for a subsequent hour under chase conditions designed either to retain newly synthesized acetylcholine within synapses or to promote its release. At the end of this time the two groups of retinas were found to contain equal amounts of radioactivity in the phospholipid pathway, but only the retinas incubated under the acetylcholine-protecting conditions contained [3H]acetylcholine. Freeze-dried, vacuum-embedded tissue from each retina was autoradiographed on dry emulsion. All retinas showed silver grains over the photoreceptor cells and faint labeling of all ganglion cells. In the retinas that contained [3H]acetylcholine, silver grains also accumulated densely over a few cells with the position of amacrine cells, over a subset of the cells of the ganglion cell layer, and in two bands over the inner plexiform layer. Fixation of the retina with aqueous osmium tetroxide retained only the radioactive compounds located in the photoreceptor and ganglion cells. Sections from freeze- dried tissue lost their water-soluble choline metabolites when exposed to water, and autoradiography of such sections again revealed radioactivity primarily in the photoreceptor and ganglion cells. Radioactive compounds extracted from the sections were found to faithfully reflect those present in the tissue before processing; analysis of the compounds eluted from sections microdissected along the outer plexiform layer showed [3H]acetylcholine to have been synthesized only by cells of the inner retina. Taken together, these results indicate that the photoreceptor and ganglion cells are

  12. Quantitative and Isolated Measurement of Far-Field Light Scattering by a Single Nanostructure

    NASA Astrophysics Data System (ADS)

    Kim, Donghyeong; Jeong, Kwang-Yong; Kim, Jinhyung; Ee, Ho-Seok; Kang, Ju-Hyung; Park, Hong-Gyu; Seo, Min-Kyo

    2017-11-01

    Light scattering by nanostructures has facilitated research on various optical phenomena and applications by interfacing the near fields and free-propagating radiation. However, direct quantitative measurement of far-field scattering by a single nanostructure on the wavelength scale or less is highly challenging. Conventional back-focal-plane imaging covers only a limited solid angle determined by the numerical aperture of the objectives and suffers from optical aberration and distortion. Here, we present a quantitative measurement of the differential far-field scattering cross section of a single nanostructure over the full hemisphere. In goniometer-based far-field scanning with a high signal-to-noise ratio of approximately 27.4 dB, weak scattering signals are efficiently isolated and detected under total-internal-reflection illumination. Systematic measurements reveal that the total and differential scattering cross sections of a Au nanorod are determined by the plasmonic Fabry-Perot resonances and the phase-matching conditions to the free-propagating radiation, respectively. We believe that our angle-resolved far-field measurement scheme provides a way to investigate and evaluate the physical properties and performance of nano-optical materials and phenomena.

  13. Quantitative facial asymmetry: using three-dimensional photogrammetry to measure baseline facial surface symmetry.

    PubMed

    Taylor, Helena O; Morrison, Clinton S; Linden, Olivia; Phillips, Benjamin; Chang, Johnny; Byrne, Margaret E; Sullivan, Stephen R; Forrest, Christopher R

    2014-01-01

    Although symmetry is hailed as a fundamental goal of aesthetic and reconstructive surgery, our tools for measuring this outcome have been limited and subjective. With the advent of three-dimensional photogrammetry, surface geometry can be captured, manipulated, and measured quantitatively. Until now, few normative data existed with regard to facial surface symmetry. Here, we present a method for reproducibly calculating overall facial symmetry and present normative data on 100 subjects. We enrolled 100 volunteers who underwent three-dimensional photogrammetry of their faces in repose. We collected demographic data on age, sex, and race and subjectively scored facial symmetry. We calculated the root mean square deviation (RMSD) between the native and reflected faces, reflecting about a plane of maximum symmetry. We analyzed the interobserver reliability of the subjective assessment of facial asymmetry and the quantitative measurements and compared the subjective and objective values. We also classified areas of greatest asymmetry as localized to the upper, middle, or lower facial thirds. This cluster of normative data was compared with a group of patients with subtle but increasing amounts of facial asymmetry. We imaged 100 subjects by three-dimensional photogrammetry. There was a poor interobserver correlation between subjective assessments of asymmetry (r = 0.56). There was a high interobserver reliability for quantitative measurements of facial symmetry RMSD calculations (r = 0.91-0.95). The mean RMSD for this normative population was found to be 0.80 ± 0.24 mm. Areas of greatest asymmetry were distributed as follows: 10% upper facial third, 49% central facial third, and 41% lower facial third. Precise measurement permitted discrimination of subtle facial asymmetry within this normative group and distinguished norms from patients with subtle facial asymmetry, with placement of RMSDs along an asymmetry ruler. Facial surface symmetry, which is poorly assessed

  14. Steps to achieve quantitative measurements of microRNA using two step droplet digital PCR.

    PubMed

    Stein, Erica V; Duewer, David L; Farkas, Natalia; Romsos, Erica L; Wang, Lili; Cole, Kenneth D

    2017-01-01

    Droplet digital PCR (ddPCR) is being advocated as a reference method to measure rare genomic targets. It has consistently been proven to be more sensitive and direct at discerning copy numbers of DNA than other quantitative methods. However, one of the largest obstacles to measuring microRNA (miRNA) using ddPCR is that reverse transcription efficiency depends upon the target, meaning small RNA nucleotide composition directly effects primer specificity in a manner that prevents traditional quantitation optimization strategies. Additionally, the use of reagents that are optimized for miRNA measurements using quantitative real-time PCR (qRT-PCR) appear to either cause false positive or false negative detection of certain targets when used with traditional ddPCR quantification methods. False readings are often related to using inadequate enzymes, primers and probes. Given that two-step miRNA quantification using ddPCR relies solely on reverse transcription and uses proprietary reagents previously optimized only for qRT-PCR, these barriers are substantial. Therefore, here we outline essential controls, optimization techniques, and an efficacy model to improve the quality of ddPCR miRNA measurements. We have applied two-step principles used for miRNA qRT-PCR measurements and leveraged the use of synthetic miRNA targets to evaluate ddPCR following cDNA synthesis with four different commercial kits. We have identified inefficiencies and limitations as well as proposed ways to circumvent identified obstacles. Lastly, we show that we can apply these criteria to a model system to confidently quantify miRNA copy number. Our measurement technique is a novel way to quantify specific miRNA copy number in a single sample, without using standard curves for individual experiments. Our methodology can be used for validation and control measurements, as well as a diagnostic technique that allows scientists, technicians, clinicians, and regulators to base miRNA measures on a single

  15. Steps to achieve quantitative measurements of microRNA using two step droplet digital PCR

    PubMed Central

    Duewer, David L.; Farkas, Natalia; Romsos, Erica L.; Wang, Lili; Cole, Kenneth D.

    2017-01-01

    Droplet digital PCR (ddPCR) is being advocated as a reference method to measure rare genomic targets. It has consistently been proven to be more sensitive and direct at discerning copy numbers of DNA than other quantitative methods. However, one of the largest obstacles to measuring microRNA (miRNA) using ddPCR is that reverse transcription efficiency depends upon the target, meaning small RNA nucleotide composition directly effects primer specificity in a manner that prevents traditional quantitation optimization strategies. Additionally, the use of reagents that are optimized for miRNA measurements using quantitative real-time PCR (qRT-PCR) appear to either cause false positive or false negative detection of certain targets when used with traditional ddPCR quantification methods. False readings are often related to using inadequate enzymes, primers and probes. Given that two-step miRNA quantification using ddPCR relies solely on reverse transcription and uses proprietary reagents previously optimized only for qRT-PCR, these barriers are substantial. Therefore, here we outline essential controls, optimization techniques, and an efficacy model to improve the quality of ddPCR miRNA measurements. We have applied two-step principles used for miRNA qRT-PCR measurements and leveraged the use of synthetic miRNA targets to evaluate ddPCR following cDNA synthesis with four different commercial kits. We have identified inefficiencies and limitations as well as proposed ways to circumvent identified obstacles. Lastly, we show that we can apply these criteria to a model system to confidently quantify miRNA copy number. Our measurement technique is a novel way to quantify specific miRNA copy number in a single sample, without using standard curves for individual experiments. Our methodology can be used for validation and control measurements, as well as a diagnostic technique that allows scientists, technicians, clinicians, and regulators to base miRNA measures on a single

  16. Quantitative dispersion microscopy

    PubMed Central

    Fu, Dan; Choi, Wonshik; Sung, Yongjin; Yaqoob, Zahid; Dasari, Ramachandra R.; Feld, Michael

    2010-01-01

    Refractive index dispersion is an intrinsic optical property and a useful source of contrast in biological imaging studies. In this report, we present the first dispersion phase imaging of living eukaryotic cells. We have developed quantitative dispersion microscopy based on the principle of quantitative phase microscopy. The dual-wavelength quantitative phase microscope makes phase measurements at 310 nm and 400 nm wavelengths to quantify dispersion (refractive index increment ratio) of live cells. The measured dispersion of living HeLa cells is found to be around 1.088, which agrees well with that measured directly for protein solutions using total internal reflection. This technique, together with the dry mass and morphology measurements provided by quantitative phase microscopy, could prove to be a useful tool for distinguishing different types of biomaterials and studying spatial inhomogeneities of biological samples. PMID:21113234

  17. Quantitative measurement of solvation shells using frequency modulated atomic force microscopy

    NASA Astrophysics Data System (ADS)

    Uchihashi, T.; Higgins, M.; Nakayama, Y.; Sader, J. E.; Jarvis, S. P.

    2005-03-01

    The nanoscale specificity of interaction measurements and additional imaging capability of the atomic force microscope make it an ideal technique for measuring solvation shells in a variety of liquids next to a range of materials. Unfortunately, the widespread use of atomic force microscopy for the measurement of solvation shells has been limited by uncertainties over the dimensions, composition and durability of the tip during the measurements, and problems associated with quantitative force calibration of the most sensitive dynamic measurement techniques. We address both these issues by the combined use of carbon nanotube high aspect ratio probes and quantifying the highly sensitive frequency modulation (FM) detection technique using a recently developed analytical method. Due to the excellent reproducibility of the measurement technique, additional information regarding solvation shell size as a function of proximity to the surface has been obtained for two very different liquids. Further, it has been possible to identify differences between chemical and geometrical effects in the chosen systems.

  18. Sensitive and quantitative measurement of gene expression directly from a small amount of whole blood.

    PubMed

    Zheng, Zhi; Luo, Yuling; McMaster, Gary K

    2006-07-01

    Accurate and precise quantification of mRNA in whole blood is made difficult by gene expression changes during blood processing, and by variations and biases introduced by sample preparations. We sought to develop a quantitative whole-blood mRNA assay that eliminates blood purification, RNA isolation, reverse transcription, and target amplification while providing high-quality data in an easy assay format. We performed single- and multiplex gene expression analysis with multiple hybridization probes to capture mRNA directly from blood lysate and used branched DNA to amplify the signal. The 96-well plate singleplex assay uses chemiluminescence detection, and the multiplex assay combines Luminex-encoded beads with fluorescent detection. The single- and multiplex assays could quantitatively measure as few as 6000 and 24,000 mRNA target molecules (0.01 and 0.04 amoles), respectively, in up to 25 microL of whole blood. Both formats had CVs < 10% and dynamic ranges of 3-4 logs. Assay sensitivities allowed quantitative measurement of gene expression in the minority of cells in whole blood. The signals from whole-blood lysate correlated well with signals from purified RNA of the same sample, and absolute mRNA quantification results from the assay were similar to those obtained by quantitative reverse transcription-PCR. Both single- and multiplex assay formats were compatible with common anticoagulants and PAXgene-treated samples; however, PAXgene preparations induced expression of known antiapoptotic genes in whole blood. Both the singleplex and the multiplex branched DNA assays can quantitatively measure mRNA expression directly from small volumes of whole blood. The assay offers an alternative to current technologies that depend on RNA isolation and is amenable to high-throughput gene expression analysis of whole blood.

  19. Feasibility of Quantitative Ultrasound Measurement of the Heel Bone in People with Intellectual Disabilities

    ERIC Educational Resources Information Center

    Mergler, S.; Lobker, B.; Evenhuis, H. M.; Penning, C.

    2010-01-01

    Low bone mineral density (BMD) and fractures are common in people with intellectual disabilities (ID). Reduced mobility in case of motor impairment and the use of anti-epileptic drugs contribute to the development of low BMD. Quantitative ultrasound (QUS) measurement of the heel bone is a non-invasive and radiation-free method for measuring bone…

  20. Accurate quantitation standards of glutathione via traceable sulfur measurement by inductively coupled plasma optical emission spectrometry and ion chromatography

    PubMed Central

    Rastogi, L.; Dash, K.; Arunachalam, J.

    2013-01-01

    The quantitative analysis of glutathione (GSH) is important in different fields like medicine, biology, and biotechnology. Accurate quantitative measurements of this analyte have been hampered by the lack of well characterized reference standards. The proposed procedure is intended to provide an accurate and definitive method for the quantitation of GSH for reference measurements. Measurement of the stoichiometrically existing sulfur content in purified GSH offers an approach for its quantitation and calibration through an appropriate characterized reference material (CRM) for sulfur would provide a methodology for the certification of GSH quantity, that is traceable to SI (International system of units). The inductively coupled plasma optical emission spectrometry (ICP-OES) approach negates the need for any sample digestion. The sulfur content of the purified GSH is quantitatively converted into sulfate ions by microwave-assisted UV digestion in the presence of hydrogen peroxide prior to ion chromatography (IC) measurements. The measurement of sulfur by ICP-OES and IC (as sulfate) using the “high performance” methodology could be useful for characterizing primary calibration standards and certified reference materials with low uncertainties. The relative expanded uncertainties (% U) expressed at 95% confidence interval for ICP-OES analyses varied from 0.1% to 0.3%, while in the case of IC, they were between 0.2% and 1.2%. The described methods are more suitable for characterizing primary calibration standards and certifying reference materials of GSH, than for routine measurements. PMID:29403814

  1. Accurate Construction of Photoactivated Localization Microscopy (PALM) Images for Quantitative Measurements

    PubMed Central

    Coltharp, Carla; Kessler, Rene P.; Xiao, Jie

    2012-01-01

    Localization-based superresolution microscopy techniques such as Photoactivated Localization Microscopy (PALM) and Stochastic Optical Reconstruction Microscopy (STORM) have allowed investigations of cellular structures with unprecedented optical resolutions. One major obstacle to interpreting superresolution images, however, is the overcounting of molecule numbers caused by fluorophore photoblinking. Using both experimental and simulated images, we determined the effects of photoblinking on the accurate reconstruction of superresolution images and on quantitative measurements of structural dimension and molecule density made from those images. We found that structural dimension and relative density measurements can be made reliably from images that contain photoblinking-related overcounting, but accurate absolute density measurements, and consequently faithful representations of molecule counts and positions in cellular structures, require the application of a clustering algorithm to group localizations that originate from the same molecule. We analyzed how applying a simple algorithm with different clustering thresholds (tThresh and dThresh) affects the accuracy of reconstructed images, and developed an easy method to select optimal thresholds. We also identified an empirical criterion to evaluate whether an imaging condition is appropriate for accurate superresolution image reconstruction with the clustering algorithm. Both the threshold selection method and imaging condition criterion are easy to implement within existing PALM clustering algorithms and experimental conditions. The main advantage of our method is that it generates a superresolution image and molecule position list that faithfully represents molecule counts and positions within a cellular structure, rather than only summarizing structural properties into ensemble parameters. This feature makes it particularly useful for cellular structures of heterogeneous densities and irregular geometries, and

  2. Quantitative measurement of feline colonic transit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krevsky, B.; Somers, M.B.; Maurer, A.H.

    1988-10-01

    Colonic transit scintigraphy, a method for quantitatively evaluating the movement of the fecal stream in vivo, was employed to evaluate colonic transit in the cat. Scintigraphy was performed in duplicate in five cats and repeated four times in one cat. After instillation of an 111In marker into the cecum through a surgically implanted silicone cecostomy tube, colonic movement of the instillate was quantitated for 24 h using gamma scintigraphy. Antegrade and retrograde motion of radionuclide was observed. The cecum and ascending colon emptied rapidly, with a half-emptying time of 1.68 +/- 0.56 h (mean +/- SE). After 24 h, 25.1more » +/- 5.2% of the activity remained in the transverse colon. The progression of the geometric center was initially rapid, followed later by a delayed phase. Geometric center reproducibility was found to be high when analyzed using simple linear regression (slope = 0.92; r = 0.73; P less than 0.01). Atropine (0.1 mg/kg im) was found to delay cecum and ascending colon emptying and delay progression of the geometric center. These results demonstrate both 1) the ability of colonic transit scintigraphy to detect changes in transit induced by pharmacological manipulation and 2) the fact that muscarinic blockade inhibits antegrade transit of the fecal stream. We conclude that feline colonic transit may be studied in a quantitative and reproducible manner with colonic transit scintigraphy.« less

  3. Development of an exposure measurement database on five lung carcinogens (ExpoSYN) for quantitative retrospective occupational exposure assessment.

    PubMed

    Peters, Susan; Vermeulen, Roel; Olsson, Ann; Van Gelder, Rainer; Kendzia, Benjamin; Vincent, Raymond; Savary, Barbara; Williams, Nick; Woldbæk, Torill; Lavoué, Jérôme; Cavallo, Domenico; Cattaneo, Andrea; Mirabelli, Dario; Plato, Nils; Dahmann, Dirk; Fevotte, Joelle; Pesch, Beate; Brüning, Thomas; Straif, Kurt; Kromhout, Hans

    2012-01-01

    SYNERGY is a large pooled analysis of case-control studies on the joint effects of occupational carcinogens and smoking in the development of lung cancer. A quantitative job-exposure matrix (JEM) will be developed to assign exposures to five major lung carcinogens [asbestos, chromium, nickel, polycyclic aromatic hydrocarbons (PAH), and respirable crystalline silica (RCS)]. We assembled an exposure database, called ExpoSYN, to enable such a quantitative exposure assessment. Existing exposure databases were identified and European and Canadian research institutes were approached to identify pertinent exposure measurement data. Results of individual air measurements were entered anonymized according to a standardized protocol. The ExpoSYN database currently includes 356 551 measurements from 19 countries. In total, 140 666 personal and 215 885 stationary data points were available. Measurements were distributed over the five agents as follows: RCS (42%), asbestos (20%), chromium (16%), nickel (15%), and PAH (7%). The measurement data cover the time period from 1951 to present. However, only a small portion of measurements (1.4%) were performed prior to 1975. The major contributing countries for personal measurements were Germany (32%), UK (22%), France (14%), and Norway and Canada (both 11%). ExpoSYN is a unique occupational exposure database with measurements from 18 European countries and Canada covering a time period of >50 years. This database will be used to develop a country-, job-, and time period-specific quantitative JEM. This JEM will enable data-driven quantitative exposure assessment in a multinational pooled analysis of community-based lung cancer case-control studies.

  4. Quantitative fundus autofluorescence in mice: correlation with HPLC quantitation of RPE lipofuscin and measurement of retina outer nuclear layer thickness.

    PubMed

    Sparrow, Janet R; Blonska, Anna; Flynn, Erin; Duncker, Tobias; Greenberg, Jonathan P; Secondi, Roberta; Ueda, Keiko; Delori, François C

    2013-04-17

    Our study was conducted to establish procedures and protocols for quantitative autofluorescence (qAF) measurements in mice, and to report changes in qAF, A2E bisretinoid concentration, and outer nuclear layer (ONL) thickness in mice of different genotypes and age. Fundus autofluorescence (AF) images (55° lens, 488 nm excitation) were acquired in albino Abca4(-/-), Abca4(+/-), and Abca4(+/+) mice (ages 2-12 months) with a confocal scanning laser ophthalmoscope (cSLO). Gray levels (GLs) in each image were calibrated to an internal fluorescence reference. The bisretinoid A2E was measured by quantitative high performance liquid chromatography (HPLC). Histometric analysis of ONL thicknesses was performed. The Bland-Altman coefficient of repeatability (95% confidence interval) was ±18% for between-session qAF measurements. Mean qAF values increased with age (2-12 months) in all groups of mice. qAF was approximately 2-fold higher in Abca4(-/-) mice than in Abca4(+/+) mice and approximately 20% higher in heterozygous mice. HPLC measurements of the lipofuscin fluorophore A2E also revealed age-associated increases, and the fold difference between Abca4(-/-) and wild-type mice was more pronounced (approximately 3-4-fold) than measurable by qAF. Moreover, A2E levels declined after 8 months of age, a change not observed with qAF. The decline in A2E levels in the Abca4(-/-) mice corresponded to reduced photoreceptor cell viability as reflected in ONL thinning beginning at 8 months of age. The qAF method enables measurement of in vivo lipofuscin and the detection of genotype and age-associated differences. The use of this approach has the potential to aid in understanding retinal disease processes and will facilitate preclinical studies.

  5. Comprehensive Comparison of Self-Administered Questionnaires for Measuring Quantitative Autistic Traits in Adults

    ERIC Educational Resources Information Center

    Nishiyama, Takeshi; Suzuki, Masako; Adachi, Katsunori; Sumi, Satoshi; Okada, Kensuke; Kishino, Hirohisa; Sakai, Saeko; Kamio, Yoko; Kojima, Masayo; Suzuki, Sadao; Kanne, Stephen M.

    2014-01-01

    We comprehensively compared all available questionnaires for measuring quantitative autistic traits (QATs) in terms of reliability and construct validity in 3,147 non-clinical and 60 clinical subjects with normal intelligence. We examined four full-length forms, the Subthreshold Autism Trait Questionnaire (SATQ), the Broader Autism Phenotype…

  6. Simple and cost-effective liquid chromatography-mass spectrometry method to measure dabrafenib quantitatively and six metabolites semi-quantitatively in human plasma.

    PubMed

    Vikingsson, Svante; Dahlberg, Jan-Olof; Hansson, Johan; Höiom, Veronica; Gréen, Henrik

    2017-06-01

    Dabrafenib is an inhibitor of BRAF V600E used for treating metastatic melanoma but a majority of patients experience adverse effects. Methods to measure the levels of dabrafenib and major metabolites during treatment are needed to allow development of individualized dosing strategies to reduce the burden of such adverse events. In this study, an LC-MS/MS method capable of measuring dabrafenib quantitatively and six metabolites semi-quantitatively is presented. The method is fully validated with regard to dabrafenib in human plasma in the range 5-5000 ng/mL. The analytes were separated on a C18 column after protein precipitation and detected in positive electrospray ionization mode using a Xevo TQ triple quadrupole mass spectrometer. As no commercial reference standards are available, the calibration curve of dabrafenib was used for semi-quantification of dabrafenib metabolites. Compared to earlier methods the presented method represents a simpler and more cost-effective approach suitable for clinical studies. Graphical abstract Combined multi reaction monitoring transitions of dabrafenib and metabolites in a typical case sample.

  7. Investigation of PACE™ software and VeriFax's Impairoscope device for quantitatively measuring the effects of stress

    NASA Astrophysics Data System (ADS)

    Morgenthaler, George W.; Nuñez, German R.; Botello, Aaron M.; Soto, Jose; Shrairman, Ruth; Landau, Alexander

    1998-01-01

    Many reaction time experiments have been conducted over the years to observe human responses. However, most of the experiments that were performed did not have quantitatively accurate instruments for measuring change in reaction time under stress. There is a great need for quantitative instruments to measure neuromuscular reaction responses under stressful conditions such as distraction, disorientation, disease, alcohol, drugs, etc. The two instruments used in the experiments reported in this paper are such devices. Their accuracy, portability, ease of use, and biometric character are what makes them very special. PACE™ is a software model used to measure reaction time. VeriFax's Impairoscope measures the deterioration of neuromuscular responses. During the 1997 Summer Semester, various reaction time experiments were conducted on University of Colorado faculty, staff, and students using the PACE™ system. The tests included both two-eye and one-eye unstressed trials and trials with various stresses such as fatigue, distractions in which subjects were asked to perform simple arithmetic during the PACE™ tests, and stress due to rotating-chair dizziness. Various VeriFax Impairoscope tests, both stressed and unstressed, were conducted to determine the Impairoscope's ability to quantitatively measure this impairment. In the 1997 Fall Semester, a Phase II effort was undertaken to increase test sample sizes in order to provide statistical precision and stability. More sophisticated statistical methods remain to be applied to better interpret the data.

  8. A novel semi-quantitative method for measuring tissue bleeding.

    PubMed

    Vukcevic, G; Volarevic, V; Raicevic, S; Tanaskovic, I; Milicic, B; Vulovic, T; Arsenijevic, S

    2014-03-01

    In this study, we describe a new semi-quantitative method for measuring the extent of bleeding in pathohistological tissue samples. To test our novel method, we recruited 120 female patients in their first trimester of pregnancy and divided them into three groups of 40. Group I was the control group, in which no dilation was applied. Group II was an experimental group, in which dilation was performed using classical mechanical dilators. Group III was also an experimental group, in which dilation was performed using a hydraulic dilator. Tissue samples were taken from the patients' cervical canals using a Novak's probe via energetic single-step curettage prior to any dilation in Group I and after dilation in Groups II and III. After the tissue samples were prepared, light microscopy was used to obtain microphotographs at 100x magnification. The surfaces affected by bleeding were measured in the microphotographs using the Autodesk AutoCAD 2009 program and its "polylines" function. The lines were used to mark the area around the entire sample (marked A) and to create "polyline" areas around each bleeding area on the sample (marked B). The percentage of the total area affected by bleeding was calculated using the formula: N = Bt x 100 / At where N is the percentage (%) of the tissue sample surface affected by bleeding, At (A total) is the sum of the surfaces of all of the tissue samples and Bt (B total) is the sum of all the surfaces affected by bleeding in all of the tissue samples. This novel semi-quantitative method utilizes the Autodesk AutoCAD 2009 program, which is simple to use and widely available, thereby offering a new, objective and precise approach to estimate the extent of bleeding in tissue samples.

  9. Comparison of MPEG-1 digital videotape with digitized sVHS videotape for quantitative echocardiographic measurements

    NASA Technical Reports Server (NTRS)

    Garcia, M. J.; Thomas, J. D.; Greenberg, N.; Sandelski, J.; Herrera, C.; Mudd, C.; Wicks, J.; Spencer, K.; Neumann, A.; Sankpal, B.; hide

    2001-01-01

    Digital format is rapidly emerging as a preferred method for displaying and retrieving echocardiographic studies. The qualitative diagnostic accuracy of Moving Pictures Experts Group (MPEG-1) compressed digital echocardiographic studies has been previously reported. The goals of the present study were to compare quantitative measurements derived from MPEG-1 recordings with the super-VHS (sVHS) videotape clinical standard. Six reviewers performed blinded measurements from still-frame images selected from 20 echocardiographic studies that were simultaneously acquired in sVHS and MPEG-1 formats. Measurements were obtainable in 1401 (95%) of 1486 MPEG-1 variables compared with 1356 (91%) of 1486 sVHS variables (P <.001). Excellent agreement existed between MPEG-1 and sVHS 2-dimensional linear measurements (r = 0.97; MPEG-1 = 0.95[sVHS] + 1.1 mm; P <.001; Delta = 9% +/- 10%), 2-dimensional area measurements (r = 0.89), color jet areas (r = 0.87, p <.001), and Doppler velocities (r = 0.92, p <.001). Interobserver variability was similar for both sVHS and MPEG-1 readings. Our results indicate that quantitative off-line measurements from MPEG-1 digitized echocardiographic studies are feasible and comparable to those obtained from sVHS.

  10. Epithelium percentage estimation facilitates epithelial quantitative protein measurement in tissue specimens.

    PubMed

    Chen, Jing; Toghi Eshghi, Shadi; Bova, George Steven; Li, Qing Kay; Li, Xingde; Zhang, Hui

    2013-12-01

    The rapid advancement of high-throughput tools for quantitative measurement of proteins has demonstrated the potential for the identification of proteins associated with cancer. However, the quantitative results on cancer tissue specimens are usually confounded by tissue heterogeneity, e.g. regions with cancer usually have significantly higher epithelium content yet lower stromal content. It is therefore necessary to develop a tool to facilitate the interpretation of the results of protein measurements in tissue specimens. Epithelial cell adhesion molecule (EpCAM) and cathepsin L (CTSL) are two epithelial proteins whose expressions in normal and tumorous prostate tissues were confirmed by measuring staining intensity with immunohistochemical staining (IHC). The expressions of these proteins were measured by ELISA in protein extracts from OCT embedded frozen prostate tissues. To eliminate the influence of tissue heterogeneity on epithelial protein quantification measured by ELISA, a color-based segmentation method was developed in-house for estimation of epithelium content using H&E histology slides from the same prostate tissues and the estimated epithelium percentage was used to normalize the ELISA results. The epithelium contents of the same slides were also estimated by a pathologist and used to normalize the ELISA results. The computer based results were compared with the pathologist's reading. We found that both EpCAM and CTSL levels, measured by ELISA assays itself, were greatly affected by epithelium content in the tissue specimens. Without adjusting for epithelium percentage, both EpCAM and CTSL levels appeared significantly higher in tumor tissues than normal tissues with a p value less than 0.001. However, after normalization by the epithelium percentage, ELISA measurements of both EpCAM and CTSL were in agreement with IHC staining results, showing a significant increase only in EpCAM with no difference in CTSL expression in cancer tissues. These results

  11. Sieve-based device for MALDI sample preparation. III. Its power for quantitative measurements.

    PubMed

    Molin, Laura; Cristoni, Simone; Seraglia, Roberta; Traldi, Pietro

    2011-02-01

    The solid sample inhomogeneity is a weak point of traditional MALDI deposition techniques that reflects negatively on quantitative analysis. The recently developed sieve-based device (SBD) sample deposition method, based on the electrospraying of matrix/analyte solutions through a grounded sieve, allows the homogeneous deposition of microcrystals with dimensions smaller than that of the laser spot. In each microcrystal the matrix/analyte molar ratio can be considered constant. Then, by irradiating different portions of the microcrystal distribution an identical response is obtained. This result suggests the employment of SBD in the development of quantitative procedures. For this aim, mixtures of different proteins of known molarity were analyzed, showing a good relationship between molarity and intensity ratios. This behaviour was also observed in the case of proteins with quite different ionic yields. The power of the developed method for quantitative evaluation was also tested by the measurement of the abundance of IGPP[Oxi]GPP[Oxi]GLMGPP (m/z 1219) present in the collagen-α-5(IV) chain precursor, differently expressed in urines from healthy subjects and diabetic-nephropathic patients, confirming its overexpression in the presence of nephropathy. The data obtained indicate that SBD is a particularly effective method for quantitative analysis also in biological fluids of interest. Copyright © 2011 John Wiley & Sons, Ltd.

  12. Serial semi-quantitative measurement of fecal calprotectin in patients with ulcerative colitis in remission.

    PubMed

    Garcia-Planella, Esther; Mañosa, Míriam; Chaparro, María; Beltrán, Belén; Barreiro-de-Acosta, Manuel; Gordillo, Jordi; Ricart, Elena; Bermejo, Fernando; García-Sánchez, Valle; Piqueras, Marta; Llaó, Jordina; Gisbert, Javier P; Cabré, Eduard; Domènech, Eugeni

    2018-02-01

    Fecal calprotectin (FC) correlates with clinical and endoscopic activity in ulcerative colitis (UC), and it is a good predictor of relapse. However, its use in clinical practice is constrained by the need for the patient to deliver stool samples, and for their handling and processing in the laboratory. The availability of hand held devices might spread the use of FC in clinical practice. To evaluate the usefulness of a rapid semi-quantitative test of FC in predicting relapse in patients with UC in remission. Prospective, multicenter study that included UC patients in clinical remission for ≥6 months on maintenance treatment with mesalamine. Patients were evaluated clinically and semi-quantitative FC was measured using a monoclonal immunochromatography rapid test at baseline and every three months until relapse or 12 months of follow-up. One hundred and ninety-one patients had at least one determination of FC. At the end of follow-up, 33 patients (17%) experienced clinical relapse. Endoscopic activity at baseline (p = .043) and having had at least one FC > 60 μg/g during the study period (p = .03) were associated with a higher risk of relapse during follow-up. We obtained a total of 636 semi-quantitative FC determinations matched with a three-month follow-up clinical assessment. Having undetectable FC was inversely associated with early relapse (within three months), with a negative predictive value of 98.6% and a sensitivity of 93.9%. Serial, rapid semi-quantitative measurement of FC may be a useful, easy and cheap monitoring tool for patients with UC in remission.

  13. The importance of quantitative measurement methods for uveitis: laser flare photometry endorsed in Europe while neglected in Japan where the technology measuring quantitatively intraocular inflammation was developed.

    PubMed

    Herbort, Carl P; Tugal-Tutkun, Ilknur

    2017-06-01

    Laser flare photometry (LFP) is an objective and quantitative method to measure intraocular inflammation. The LFP technology was developed in Japan and has been commercially available since 1990. The aim of this work was to review the application of LFP in uveitis practice in Europe compared to Japan where the technology was born. We reviewed PubMed articles published on LFP and uveitis. Although LFP has been largely integrated in routine uveitis practice in Europe, it has been comparatively neglected in Japan and still has not received FDA approval in the USA. As LFP is the only method that provides a precise measure of intraocular inflammation, it should be used as a gold standard in uveitis centres worldwide.

  14. An Improved Method for Measuring Quantitative Resistance to the Wheat Pathogen Zymoseptoria tritici Using High-Throughput Automated Image Analysis.

    PubMed

    Stewart, Ethan L; Hagerty, Christina H; Mikaberidze, Alexey; Mundt, Christopher C; Zhong, Ziming; McDonald, Bruce A

    2016-07-01

    Zymoseptoria tritici causes Septoria tritici blotch (STB) on wheat. An improved method of quantifying STB symptoms was developed based on automated analysis of diseased leaf images made using a flatbed scanner. Naturally infected leaves (n = 949) sampled from fungicide-treated field plots comprising 39 wheat cultivars grown in Switzerland and 9 recombinant inbred lines (RIL) grown in Oregon were included in these analyses. Measures of quantitative resistance were percent leaf area covered by lesions, pycnidia size and gray value, and pycnidia density per leaf and lesion. These measures were obtained automatically with a batch-processing macro utilizing the image-processing software ImageJ. All phenotypes in both locations showed a continuous distribution, as expected for a quantitative trait. The trait distributions at both sites were largely overlapping even though the field and host environments were quite different. Cultivars and RILs could be assigned to two or more statistically different groups for each measured phenotype. Traditional visual assessments of field resistance were highly correlated with quantitative resistance measures based on image analysis for the Oregon RILs. These results show that automated image analysis provides a promising tool for assessing quantitative resistance to Z. tritici under field conditions.

  15. Nigrothalamic projections in the monkey demonstrated by autoradiographic technics.

    PubMed

    Carpenter, M B; Nakano, K; Kim, R

    1976-02-15

    In spite of repeated demonstrations by degeneration technics, nigrothalamic fibers have been regarded with some skepticism. Attempts were made to trace nigral efferent projections in the monkey by autoradiographic technics. Tritiated amino acids (L-leucine, L-lysine and L-proline), injected into portions of the substantia nigra (SN), labeled cells in four regions, designated as, (1) rostrolateral, (2) caudolateral, (3) rostromedial and (4) central. Rostrolateral nigral neurons transported radioactive label preferentially and abundantly to thalamic nuclei; localized isotope was found in parts of three thalamic nuclei, the medial part of the ventral lateral nucleus (VLm), the magnocellular part of the ventral anterior nucleus (VAmc), and the paralaminar part of the dorsomedial nucleus (DMpl)9 Lateral neurons in the caudal half of the SN transmitted radioactive label to the same thalamic nuclei as rostrolateral nigral neuron. Isotope transported to portions of the striatum was modest and localized. Radioactive label taken up by large cells in the caudal third of the SN was transported to portions of the striatum, but not to thalamic nuclei. Labeled nigral neurons in the medial two-thirds of the rostral half of the SN, and in the middle third of the central part of the SN, transported the label mainly to parts of the caudate nucleus and putamen. In these animals modest radioactive label was seen in VLm and VAmc, but not in other thalamic nuclei. There was no evidence that nigral neurons project to the subthalamic nucleus. No radioactive transport from nigral neurons was detected in the superior colliculus, the midbrain tegmentum, or the red nucleus, and none was transported to more caudal brain stem nuclei. Nigrothalamic fibers arise particularly from cells in rostral and lateral parts of the substantia nigra. While some cells in other parts of the nigra project to thalamic nuclei, these appear scattered and less numerous. Large cells in caudal parts of the SN do not

  16. Quantitative surface temperature measurement using two-color thermographic phosphors and video equipment

    NASA Technical Reports Server (NTRS)

    Buck, Gregory M. (Inventor)

    1989-01-01

    A thermal imaging system provides quantitative temperature information and is particularly useful in hypersonic wind tunnel applications. An object to be measured is prepared by coating with a two-color, ultraviolet-activated, thermographic phosphor. The colors emitted by the phosphor are detected by a conventional color video camera. A phosphor emitting blue and green light with a ratio that varies depending on temperature is used so that the intensity of light in the blue and green wavelengths detected by the blue and green tubes in the video camera can be compared. Signals representing the intensity of blue and green light at points on the surface of a model in a hypersonic wind tunnel are used to calculate a ratio of blue to green light intensity which provides quantitative temperature information for the surface of the model.

  17. Novel method for quantitative ANA measurement using near-infrared imaging.

    PubMed

    Peterson, Lisa K; Wells, Daniel; Shaw, Laura; Velez, Maria-Gabriela; Harbeck, Ronald; Dragone, Leonard L

    2009-09-30

    Antinuclear antibodies (ANA) have been detected in patients with systemic rheumatic diseases and are used in the screening and/or diagnosis of autoimmunity in patients as well as mouse models of systemic autoimmunity. Indirect immunofluorescence (IIF) on HEp-2 cells is the gold standard for ANA screening. However, its usefulness is limited in diagnosis, prognosis and monitoring of disease activity due to the lack of standardization in performing the technique, subjectivity in interpreting the results and the fact that it is only semi-quantitative. Various immunological techniques have been developed in an attempt to improve upon the method to quantify ANA, including enzyme-linked immunosorbent assays (ELISAs), line immunoassays (LIAs), multiplexed bead immunoassays and IIF on substrates other than HEp-2 cells. Yet IIF on HEp-2 cells remains the most common screening method for ANA. In this study, we describe a simple quantitative method to detect ANA which combines IIF on HEp-2 coated slides with analysis using a near-infrared imaging (NII) system. Using NII to determine ANA titer, 86.5% (32 of 37) of the titers for human patient samples were within 2 dilutions of those determined by IIF, which is the acceptable range for proficiency testing. Combining an initial screening for nuclear staining using microscopy with titration by NII resulted in 97.3% (36 of 37) of the titers detected to be within two dilutions of those determined by IIF. The NII method for quantitative ANA measurements using serum from both patients and mice with autoimmunity provides a fast, relatively simple, objective, sensitive and reproducible assay, which could easily be standardized for comparison between laboratories.

  18. Quantitative Measurement of Local Infrared Absorption and Dielectric Function with Tip-Enhanced Near-Field Microscopy.

    PubMed

    Govyadinov, Alexander A; Amenabar, Iban; Huth, Florian; Carney, P Scott; Hillenbrand, Rainer

    2013-05-02

    Scattering-type scanning near-field optical microscopy (s-SNOM) and Fourier transform infrared nanospectroscopy (nano-FTIR) are emerging tools for nanoscale chemical material identification. Here, we push s-SNOM and nano-FTIR one important step further by enabling them to quantitatively measure local dielectric constants and infrared absorption. Our technique is based on an analytical model, which allows for a simple inversion of the near-field scattering problem. It yields the dielectric permittivity and absorption of samples with 2 orders of magnitude improved spatial resolution compared to far-field measurements and is applicable to a large class of samples including polymers and biological matter. We verify the capabilities by determining the local dielectric permittivity of a PMMA film from nano-FTIR measurements, which is in excellent agreement with far-field ellipsometric data. We further obtain local infrared absorption spectra with unprecedented accuracy in peak position and shape, which is the key to quantitative chemometrics on the nanometer scale.

  19. Measuring the Nonuniform Evaporation Dynamics of Sprayed Sessile Microdroplets with Quantitative Phase Imaging.

    PubMed

    Edwards, Chris; Arbabi, Amir; Bhaduri, Basanta; Wang, Xiaozhen; Ganti, Raman; Yunker, Peter J; Yodh, Arjun G; Popescu, Gabriel; Goddard, Lynford L

    2015-10-13

    We demonstrate real-time quantitative phase imaging as a new optical approach for measuring the evaporation dynamics of sessile microdroplets. Quantitative phase images of various droplets were captured during evaporation. The images enabled us to generate time-resolved three-dimensional topographic profiles of droplet shape with nanometer accuracy and, without any assumptions about droplet geometry, to directly measure important physical parameters that characterize surface wetting processes. Specifically, the time-dependent variation of the droplet height, volume, contact radius, contact angle distribution along the droplet's perimeter, and mass flux density for two different surface preparations are reported. The studies clearly demonstrate three phases of evaporation reported previously: pinned, depinned, and drying modes; the studies also reveal instances of partial pinning. Finally, the apparatus is employed to investigate the cooperative evaporation of the sprayed droplets. We observe and explain the neighbor-induced reduction in evaporation rate, that is, as compared to predictions for isolated droplets. In the future, the new experimental methods should stimulate the exploration of colloidal particle dynamics on the gas-liquid-solid interface.

  20. Quantitative evaluation of statistical errors in small-angle X-ray scattering measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sedlak, Steffen M.; Bruetzel, Linda K.; Lipfert, Jan

    A new model is proposed for the measurement errors incurred in typical small-angle X-ray scattering (SAXS) experiments, which takes into account the setup geometry and physics of the measurement process. The model accurately captures the experimentally determined errors from a large range of synchrotron and in-house anode-based measurements. Its most general formulation gives for the variance of the buffer-subtracted SAXS intensity σ 2(q) = [I(q) + const.]/(kq), whereI(q) is the scattering intensity as a function of the momentum transferq;kand const. are fitting parameters that are characteristic of the experimental setup. The model gives a concrete procedure for calculating realistic measurementmore » errors for simulated SAXS profiles. In addition, the results provide guidelines for optimizing SAXS measurements, which are in line with established procedures for SAXS experiments, and enable a quantitative evaluation of measurement errors.« less

  1. Electrons, Photons, and Force: Quantitative Single-Molecule Measurements from Physics to Biology

    PubMed Central

    2011-01-01

    Single-molecule measurement techniques have illuminated unprecedented details of chemical behavior, including observations of the motion of a single molecule on a surface, and even the vibration of a single bond within a molecule. Such measurements are critical to our understanding of entities ranging from single atoms to the most complex protein assemblies. We provide an overview of the strikingly diverse classes of measurements that can be used to quantify single-molecule properties, including those of single macromolecules and single molecular assemblies, and discuss the quantitative insights they provide. Examples are drawn from across the single-molecule literature, ranging from ultrahigh vacuum scanning tunneling microscopy studies of adsorbate diffusion on surfaces to fluorescence studies of protein conformational changes in solution. PMID:21338175

  2. Airborne radar and radiometer experiment for quantitative remote measurements of rain

    NASA Technical Reports Server (NTRS)

    Kozu, Toshiaki; Meneghini, Robert; Boncyk, Wayne; Wilheit, Thomas T.; Nakamura, Kenji

    1989-01-01

    An aircraft experiment has been conducted with a dual-frequency (10 GHz and 35 GHz) radar/radiometer system and an 18-GHz radiometer to test various rain-rate retrieval algorithms from space. In the experiment, which took place in the fall of 1988 at the NASA Wallops Flight Facility, VA, both stratiform and convective storms were observed. A ground-based radar and rain gauges were also used to obtain truth data. An external radar calibration is made with rain gauge data, thereby enabling quantitative reflectivity measurements. Comparisons between path attenuations derived from the surface return and from the radar reflectivity profile are made to test the feasibility of a technique to estimate the raindrop size distribution from simultaneous radar and path-attenuation measurements.

  3. High throughput and quantitative approaches for measuring circadian rhythms in cyanobacteria using bioluminescence

    PubMed Central

    Shultzaberger, Ryan K.; Paddock, Mark L.; Katsuki, Takeo; Greenspan, Ralph J.; Golden, Susan S.

    2016-01-01

    The temporal measurement of a bioluminescent reporter has proven to be one of the most powerful tools for characterizing circadian rhythms in the cyanobacterium Synechococcus elongatus. Primarily, two approaches have been used to automate this process: (1) detection of cell culture bioluminescence in 96-well plates by a photomultiplier tube-based plate-cycling luminometer (TopCount Microplate Scintillation and Luminescence Counter, Perkin Elmer) and (2) detection of individual colony bioluminescence by iteratively rotating a Petri dish under a cooled CCD camera using a computer-controlled turntable. Each approach has distinct advantages. The TopCount provides a more quantitative measurement of bioluminescence, enabling the direct comparison of clock output levels among strains. The computer-controlled turntable approach has a shorter set-up time and greater throughput, making it a more powerful phenotypic screening tool. While the latter approach is extremely useful, only a few labs have been able to build such an apparatus because of technical hurdles involved in coordinating and controlling both the camera and the turntable, and in processing the resulting images. This protocol provides instructions on how to construct, use, and process data from a computer-controlled turntable to measure the temporal changes in bioluminescence of individual cyanobacterial colonies. Furthermore, we describe how to prepare samples for use with the TopCount to minimize experimental noise, and generate meaningful quantitative measurements of clock output levels for advanced analysis. PMID:25662451

  4. Formation resistivity measurements from within a cased well used to quantitatively determine the amount of oil and gas present

    DOEpatents

    Vail, III, William B.

    1997-01-01

    Methods to quantitatively determine the separate amounts of oil and gas in a geological formation adjacent to a cased well using measurements of formation resistivity are disclosed. The steps include obtaining resistivity measurements from within a cased well of a given formation, obtaining the porosity, obtaining the resistivity of formation water present, computing the combined amounts of oil and gas present using Archie's Equations, determining the relative amounts of oil and gas present from measurements within a cased well, and then quantitatively determining the separate amounts of oil and gas present in the formation.

  5. Reineke’s stand density index: a quantitative and non-unitless measure of stand density

    Treesearch

    Curtis L. VanderSchaaf

    2013-01-01

    When used as a measure of relative density, Reineke’s stand density index (SDI) can be made unitless by relating the current SDI to a standard density but when used as a quantitative measure of stand density SDI is not unitless. Reineke’s SDI relates the current stand density to an equivalent number of trees per unit area in a stand with a quadratic mean diameter (Dq)...

  6. Quantitative measurements of nanoscale permittivity and conductivity using tuning-fork-based microwave impedance microscopy

    NASA Astrophysics Data System (ADS)

    Wu, Xiaoyu; Hao, Zhenqi; Wu, Di; Zheng, Lu; Jiang, Zhanzhi; Ganesan, Vishal; Wang, Yayu; Lai, Keji

    2018-04-01

    We report quantitative measurements of nanoscale permittivity and conductivity using tuning-fork (TF) based microwave impedance microscopy (MIM). The system is operated under the driving amplitude modulation mode, which ensures satisfactory feedback stability on samples with rough surfaces. The demodulated MIM signals on a series of bulk dielectrics are in good agreement with results simulated by finite-element analysis. Using the TF-MIM, we have visualized the evolution of nanoscale conductance on back-gated MoS2 field effect transistors, and the results are consistent with the transport data. Our work suggests that quantitative analysis of mesoscopic electrical properties can be achieved by near-field microwave imaging with small distance modulation.

  7. Evaluation of quantitative PCR measurement of bacterial colonization of epithelial cells.

    PubMed

    Schmidt, Marcin T; Olejnik-Schmidt, Agnieszka K; Myszka, Kamila; Borkowska, Monika; Grajek, Włodzimierz

    2010-01-01

    Microbial colonization is an important step in establishing pathogenic or probiotic relations to host cells and in biofilm formation on industrial or medical devices. The aim of this work was to verify the applicability of quantitative PCR (Real-Time PCR) to measure bacterial colonization of epithelial cells. Salmonella enterica and Caco-2 intestinal epithelial cell line was used as a model. To verify sensitivity of the assay a competition of the pathogen cells to probiotic microorganism was tested. The qPCR method was compared to plate count and radiolabel approach, which are well established techniques in this area of research. The three methods returned similar results. The best quantification accuracy had radiolabel method, followed by qPCR. The plate count results showed coefficient of variation two-times higher than this of qPCR. The quantitative PCR proved to be a reliable method for enumeration of microbes in colonization assay. It has several advantages that make it very useful in case of analyzing mixed populations, where several different species or even strains can be monitored at the same time.

  8. Timed function tests, motor function measure, and quantitative thigh muscle MRI in ambulant children with Duchenne muscular dystrophy: A cross-sectional analysis.

    PubMed

    Schmidt, Simone; Hafner, Patricia; Klein, Andrea; Rubino-Nacht, Daniela; Gocheva, Vanya; Schroeder, Jonas; Naduvilekoot Devasia, Arjith; Zuesli, Stephanie; Bernert, Guenther; Laugel, Vincent; Bloetzer, Clemens; Steinlin, Maja; Capone, Andrea; Gloor, Monika; Tobler, Patrick; Haas, Tanja; Bieri, Oliver; Zumbrunn, Thomas; Fischer, Dirk; Bonati, Ulrike

    2018-01-01

    The development of new therapeutic agents for the treatment of Duchenne muscular dystrophy has put a focus on defining outcome measures most sensitive to capture treatment effects. This cross-sectional analysis investigates the relation between validated clinical assessments such as the 6-minute walk test, motor function measure and quantitative muscle MRI of thigh muscles in ambulant Duchenne muscular dystrophy patients, aged 6.5 to 10.8 years (mean 8.2, SD 1.1). Quantitative muscle MRI included the mean fat fraction using a 2-point Dixon technique, and transverse relaxation time (T2) measurements. All clinical assessments were highly significantly inter-correlated with p < 0.001. The strongest correlation with the motor function measure and its D1-subscore was shown by the 6-minute walk test. Clinical assessments showed no correlation with age. Importantly, quantitative muscle MRI values significantly correlated with all clinical assessments with the extensors showing the strongest correlation. In contrast to the clinical assessments, quantitative muscle MRI values were highly significantly correlated with age. In conclusion, the motor function measure and timed function tests measure disease severity in a highly comparable fashion and all tests correlated with quantitative muscle MRI values quantifying fatty muscle degeneration. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Retrieving the Quantitative Chemical Information at Nanoscale from Scanning Electron Microscope Energy Dispersive X-ray Measurements by Machine Learning

    NASA Astrophysics Data System (ADS)

    Jany, B. R.; Janas, A.; Krok, F.

    2017-11-01

    The quantitative composition of metal alloy nanowires on InSb(001) semiconductor surface and gold nanostructures on germanium surface is determined by blind source separation (BSS) machine learning (ML) method using non negative matrix factorization (NMF) from energy dispersive X-ray spectroscopy (EDX) spectrum image maps measured in a scanning electron microscope (SEM). The BSS method blindly decomposes the collected EDX spectrum image into three source components, which correspond directly to the X-ray signals coming from the supported metal nanostructures, bulk semiconductor signal and carbon background. The recovered quantitative composition is validated by detailed Monte Carlo simulations and is confirmed by separate cross-sectional TEM EDX measurements of the nanostructures. This shows that SEM EDX measurements together with machine learning blind source separation processing could be successfully used for the nanostructures quantitative chemical composition determination.

  10. Quantitative echocardiographic measures in the assessment of single ventricle function post-Fontan: Incorporation into routine clinical practice.

    PubMed

    Rios, Rodrigo; Ginde, Salil; Saudek, David; Loomba, Rohit S; Stelter, Jessica; Frommelt, Peter

    2017-01-01

    Quantitative echocardiographic measurements of single ventricular (SV) function have not been incorporated into routine clinical practice. A clinical protocol, which included quantitative measurements of SV deformation (global circumferential and longitudinal strain and strain rate), standard deviation of time to peak systolic strain, myocardial performance index (MPI), dP/dT from an atrioventricular valve regurgitant jet, and superior mesenteric artery resistance index, was instituted for all patients with a history of Fontan procedure undergoing echocardiography. All measures were performed real time during clinically indicated studies and were included in clinical reports. A total of 100 consecutive patients (mean age = 11.95±6.8 years, range 17 months-31.3 years) completed the protocol between September 1, 2014 to April 29, 2015. Deformation measures were completed in 100% of the studies, MPI in 93%, dP/dT in 55%, and superior mesenteric artery Doppler in 82%. The studies were reviewed to assess for efficiency in completing the protocol. The average time for image acquisition was 27.4±8.8 (range 10-62 minutes). The average time to perform deformation measures was 10.8±5.5 minutes (range 5-35 minutes) and time from beginning of imaging to report completion was 53.4±13.7 minutes (range 27-107 minutes). There was excellent inter-observer reliability when deformation indices were blindly repeated. Patients with a single left ventricle had significantly higher circumferential strain and strain rate, longitudinal strain and strain rate, and dP/dT compared to a single right ventricle. There were no differences in quantitative indices of ventricular function between patients <10 vs. >10 years post-Fontan. Advanced quantitative assessment of SV function post-Fontan can be consistently and efficiently performed real time during clinically indicated echocardiograms with excellent reliability. © 2016, Wiley Periodicals, Inc.

  11. Quantitative measurements of intercellular adhesion between a macrophage and cancer cells using a cup-attached AFM chip.

    PubMed

    Kim, Hyonchol; Yamagishi, Ayana; Imaizumi, Miku; Onomura, Yui; Nagasaki, Akira; Miyagi, Yohei; Okada, Tomoko; Nakamura, Chikashi

    2017-07-01

    Intercellular adhesion between a macrophage and cancer cells was quantitatively measured using atomic force microscopy (AFM). Cup-shaped metal hemispheres were fabricated using polystyrene particles as a template, and a cup was attached to the apex of the AFM cantilever. The cup-attached AFM chip (cup-chip) approached a murine macrophage cell (J774.2), the cell was captured on the inner concave of the cup, and picked up by withdrawing the cup-chip from the substrate. The cell-attached chip was advanced towards a murine breast cancer cell (FP10SC2), and intercellular adhesion between the two cells was quantitatively measured. To compare cell adhesion strength, the work required to separate two adhered cells (separation work) was used as a parameter. Separation work was almost 2-fold larger between a J774.2 cell and FP10SC2 cell than between J774.2 cell and three additional different cancer cells (4T1E, MAT-LyLu, and U-2OS), two FP10SC2 cells, or two J774.2 cells. FP10SC2 was established from 4T1E as a highly metastatic cell line, indicates separation work increased as the malignancy of cancer cells became higher. One possible explanation of the strong adhesion of macrophages to cancer cells observed in this study is that the measurement condition mimicked the microenvironment of tumor-associated macrophages (TAMs) in vivo, and J774.2 cells strongly expressed CD204, which is a marker of TAMs. The results of the present study, which were obtained by measuring cell adhesion strength quantitatively, indicate that the fabricated cup-chip is a useful tool for measuring intercellular adhesion easily and quantitatively. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Quantitative Measures of Swallowing Deficits in Patients With Parkinson's Disease.

    PubMed

    Ellerston, Julia K; Heller, Amanda C; Houtz, Daniel R; Kendall, Katherine A

    2016-05-01

    Dysphagia and associated aspiration pneumonia are commonly reported sequelae of Parkinson's disease (PD). Previous studies of swallowing in patients with PD have described prolonged pharyngeal transit time, delayed onset of pharyngeal transit, cricopharyngeal (CP) achalasia, reduced pharyngeal constriction, and slowed hyolaryngeal elevation. These studies were completed using inconsistent evaluation methodology, reliance on qualitative analysis, and a lack of a large control group, resulting in concerns regarding diagnostic precision. The purpose of this study was to investigate swallowing function in patients with PD using a norm-referenced, quantitative approach. This retrospective study includes 34 patients with a diagnosis of PD referred to a multidisciplinary voice and swallowing clinic. Modified barium swallow studies were performed using quantitative measures of pharyngeal transit time, hyoid displacement, CP sphincter opening, area of the pharynx at maximal constriction, and timing of laryngeal vestibule closure relative to bolus arrival at the CP sphincter. Reduced pharyngeal constriction was found in 30.4%, and a delay in airway closure relative to arrival of the bolus at the CP sphincter was the most common abnormality, present in 62% of patients. Previously reported findings of prolonged pharyngeal transit, poor hyoid elevation, and CP achalasia were not identified as prominent features. © The Author(s) 2015.

  13. Measuring changes in transmission of neglected tropical diseases, malaria, and enteric pathogens from quantitative antibody levels.

    PubMed

    Arnold, Benjamin F; van der Laan, Mark J; Hubbard, Alan E; Steel, Cathy; Kubofcik, Joseph; Hamlin, Katy L; Moss, Delynn M; Nutman, Thomas B; Priest, Jeffrey W; Lammie, Patrick J

    2017-05-01

    Serological antibody levels are a sensitive marker of pathogen exposure, and advances in multiplex assays have created enormous potential for large-scale, integrated infectious disease surveillance. Most methods to analyze antibody measurements reduce quantitative antibody levels to seropositive and seronegative groups, but this can be difficult for many pathogens and may provide lower resolution information than quantitative levels. Analysis methods have predominantly maintained a single disease focus, yet integrated surveillance platforms would benefit from methodologies that work across diverse pathogens included in multiplex assays. We developed an approach to measure changes in transmission from quantitative antibody levels that can be applied to diverse pathogens of global importance. We compared age-dependent immunoglobulin G curves in repeated cross-sectional surveys between populations with differences in transmission for multiple pathogens, including: lymphatic filariasis (Wuchereria bancrofti) measured before and after mass drug administration on Mauke, Cook Islands, malaria (Plasmodium falciparum) before and after a combined insecticide and mass drug administration intervention in the Garki project, Nigeria, and enteric protozoans (Cryptosporidium parvum, Giardia intestinalis, Entamoeba histolytica), bacteria (enterotoxigenic Escherichia coli, Salmonella spp.), and viruses (norovirus groups I and II) in children living in Haiti and the USA. Age-dependent antibody curves fit with ensemble machine learning followed a characteristic shape across pathogens that aligned with predictions from basic mechanisms of humoral immunity. Differences in pathogen transmission led to shifts in fitted antibody curves that were remarkably consistent across pathogens, assays, and populations. Mean antibody levels correlated strongly with traditional measures of transmission intensity, such as the entomological inoculation rate for P. falciparum (Spearman's rho = 0.75). In

  14. A quantitative ELISA procedure for the measurement of membrane-bound platelet-associated IgG (PAIgG).

    PubMed

    Lynch, D M; Lynch, J M; Howe, S E

    1985-03-01

    A quantitative ELISA assay for the measurement of in vivo bound platelet-associated IgG (PAIgG) using intact patient platelets is presented. The assay requires quantitation and standardization of the number of platelets bound to microtiter plate wells and an absorbance curve using quantitated IgG standards. Platelet-bound IgG was measured using an F(ab')2 peroxidase labeled anti-human IgG and o-phenylenediamine dihydrochloride (OPD) as the substrate. Using this assay, PAIgG for normal individuals was 2.8 +/- 1.6 fg/platelet (mean +/- 1 SD; n = 30). Increased levels were found in 28 of 30 patients with clinical autoimmune thrombocytopenia (ATP) with a range of 7.0-80 fg/platelet. Normal PAIgG levels were found in 26 of 30 patients with nonimmune thrombocytopenia. In the sample population studied, the PAIgG assay showed a sensitivity of 93%, specificity of 90%, a positive predictive value of 0.90, and a negative predictive value of 0.93. The procedure is highly reproducible (CV = 6.8%) and useful in evaluating patients with suspected immune mediated thrombocytopenia.

  15. Quantitative and simultaneous non-invasive measurement of skin hydration and sebum levels

    PubMed Central

    Ezerskaia, Anna; Pereira, S. F.; Urbach, H. Paul; Verhagen, Rieko; Varghese, Babu

    2016-01-01

    We report a method on quantitative and simultaneous non-contact in-vivo hydration and sebum measurements of the skin using an infrared optical spectroscopic set-up. The method utilizes differential detection with three wavelengths 1720, 1750, and 1770 nm, corresponding to the lipid vibrational bands that lay “in between” the prominent water absorption bands. We have used an emulsifier containing hydro- and lipophilic components to mix water and sebum in various volume fractions which was applied to the skin to mimic different oily-dry skin conditions. We also measured the skin sebum and hydration values on the forehead under natural conditions and its variations to external stimuli. Good agreement was found between our experimental results and reference values measured using conventional biophysical methods such as Corneometer and Sebumeter. PMID:27375946

  16. Piezoelectric tuning fork biosensors for the quantitative measurement of biomolecular interactions

    NASA Astrophysics Data System (ADS)

    Gonzalez, Laura; Rodrigues, Mafalda; Benito, Angel Maria; Pérez-García, Lluïsa; Puig-Vidal, Manel; Otero, Jorge

    2015-12-01

    The quantitative measurement of biomolecular interactions is of great interest in molecular biology. Atomic force microscopy (AFM) has proved its capacity to act as a biosensor and determine the affinity between biomolecules of interest. Nevertheless, the detection scheme presents certain limitations when it comes to developing a compact biosensor. Recently, piezoelectric quartz tuning forks (QTFs) have been used as laser-free detection sensors for AFM. However, only a few studies along these lines have considered soft biological samples, and even fewer constitute quantified molecular recognition experiments. Here, we demonstrate the capacity of QTF probes to perform specific interaction measurements between biotin-streptavidin complexes in buffer solution. We propose in this paper a variant of dynamic force spectroscopy based on representing adhesion energies E (aJ) against pulling rates v (nm s-1). Our results are compared with conventional AFM measurements and show the great potential of these sensors in molecular interaction studies.

  17. Evaluation of patients with painful total hip arthroplasty using combined single photon emission tomography and conventional computerized tomography (SPECT/CT) - a comparison of semi-quantitative versus 3D volumetric quantitative measurements.

    PubMed

    Barthassat, Emilienne; Afifi, Faik; Konala, Praveen; Rasch, Helmut; Hirschmann, Michael T

    2017-05-08

    It was the primary purpose of our study to evaluate the inter- and intra-observer reliability of a standardized SPECT/CT algorithm for evaluating patients with painful primary total hip arthroplasty (THA). The secondary purpose was a comparison of semi-quantitative and 3D volumetric quantification method for assessment of bone tracer uptake (BTU) in those patients. A novel SPECT/CT localization scheme consisting of 14 femoral and 4 acetabular regions on standardized axial and coronal slices was introduced and evaluated in terms of inter- and intra-observer reliability in 37 consecutive patients with hip pain after THA. BTU for each anatomical region was assessed semi-quantitatively using a color-coded Likert type scale (0-10) and volumetrically quantified using a validated software. Two observers interpreted the SPECT/CT findings in all patients two times with six weeks interval between interpretations in random order. Semi-quantitative and quantitative measurements were compared in terms of reliability. In addition, the values were correlated using Pearson`s correlation. A factorial cluster analysis of BTU was performed to identify clinically relevant regions, which should be grouped and analysed together. The localization scheme showed high inter- and intra-observer reliabilities for all femoral and acetabular regions independent of the measurement method used (semiquantitative versus 3D volumetric quantitative measurements). A high to moderate correlation between both measurement methods was shown for the distal femur, the proximal femur and the acetabular cup. The factorial cluster analysis showed that the anatomical regions might be summarized into three distinct anatomical regions. These were the proximal femur, the distal femur and the acetabular cup region. The SPECT/CT algorithm for assessment of patients with pain after THA is highly reliable independent from the measurement method used. Three clinically relevant anatomical regions (proximal femoral

  18. Gold Nanoparticle Labeling Based ICP-MS Detection/Measurement of Bacteria, and Their Quantitative Photothermal Destruction

    PubMed Central

    Lin, Yunfeng

    2015-01-01

    Bacteria such as Salmonella and E. coli present a great challenge in public health care in today’s society. Protection of public safety against bacterial contamination and rapid diagnosis of infection require simple and fast assays for the detection and elimination of bacterial pathogens. After utilizing Salmonella DT104 as an example bacterial strain for our investigation, we report a rapid and sensitive assay for the qualitative and quantitative detection of bacteria by using antibody affinity binding, popcorn shaped gold nanoparticle (GNPOPs) labeling, surfance enchanced Raman spectroscopy (SERS), and inductively coupled plasma mass spectrometry (ICP-MS) detection. For qualitative analysis, our assay can detect Salmonella within 10 min by Raman spectroscopy; for quantitative analysis, our assay has the ability to measure as few as 100 Salmonella DT104 in a 1 mL sample (100 CFU/mL) within 40 min. Based on the quantitative detection, we investigated the quantitative destruction of Salmonella DT104, and the assay’s photothermal efficiency in order to reduce the amount of GNPOPs in the assay to ultimately to eliminate any potential side effects/toxicity to the surrounding cells in vivo. Results suggest that our assay may serve as a promising candidate for qualitative and quantitative detection and elimination of a variety of bacterial pathogens. PMID:26417447

  19. Correlation of visual in vitro cytotoxicity ratings of biomaterials with quantitative in vitro cell viability measurements.

    PubMed

    Bhatia, Sujata K; Yetter, Ann B

    2008-08-01

    Medical devices and implanted biomaterials are often assessed for biological reactivity using visual scores of cell-material interactions. In such testing, biomaterials are assigned cytotoxicity ratings based on visual evidence of morphological cellular changes, including cell lysis, rounding, spreading, and proliferation. For example, ISO 10993 cytotoxicity testing of medical devices allows the use of a visual grading scale. The present study compared visual in vitro cytotoxicity ratings to quantitative in vitro cytotoxicity measurements for biomaterials to determine the level of correlation between visual scoring and a quantitative cell viability assay. Biomaterials representing a spectrum of biological reactivity levels were evaluated, including organo-tin polyvinylchloride (PVC; a known cytotoxic material), ultra-high molecular weight polyethylene (a known non-cytotoxic material), and implantable tissue adhesives. Each material was incubated in direct contact with mouse 3T3 fibroblast cell cultures for 24 h. Visual scores were assigned to the materials using a 5-point rating scale; the scorer was blinded to the material identities. Quantitative measurements of cell viability were performed using a 3-(4,5-dimethylthiozol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) colorimetric assay; again, the assay operator was blinded to material identities. The investigation revealed a high degree of correlation between visual cytotoxicity ratings and quantitative cell viability measurements; a Pearson's correlation gave a correlation coefficient of 0.90 between the visual cytotoxicity score and the percent viable cells. An equation relating the visual cytotoxicity score and the percent viable cells was derived. The results of this study are significant for the design and interpretation of in vitro cytotoxicity studies of novel biomaterials.

  20. Assessment of Renal Hemodynamics and Oxygenation by Simultaneous Magnetic Resonance Imaging (MRI) and Quantitative Invasive Physiological Measurements.

    PubMed

    Cantow, Kathleen; Arakelyan, Karen; Seeliger, Erdmann; Niendorf, Thoralf; Pohlmann, Andreas

    2016-01-01

    In vivo assessment of renal perfusion and oxygenation under (patho)physiological conditions by means of noninvasive diagnostic imaging is conceptually appealing. Blood oxygen level-dependent (BOLD) magnetic resonance imaging (MRI) and quantitative parametric mapping of the magnetic resonance (MR) relaxation times T 2* and T 2 are thought to provide surrogates of renal tissue oxygenation. The validity and efficacy of this technique for quantitative characterization of local tissue oxygenation and its changes under different functional conditions have not been systematically examined yet and remain to be established. For this purpose, the development of an integrative multimodality approaches is essential. Here we describe an integrated hybrid approach (MR-PHYSIOL) that combines established quantitative physiological measurements with T 2* (T 2) mapping and MR-based kidney size measurements. Standardized reversible (patho)physiologically relevant interventions, such as brief periods of aortic occlusion, hypoxia, and hyperoxia, are used for detailing the relation between the MR-PHYSIOL parameters, in particular between renal T 2* and tissue oxygenation.

  1. The Reliability and Validity of Discrete and Continuous Measures of Psychopathology: A Quantitative Review

    ERIC Educational Resources Information Center

    Markon, Kristian E.; Chmielewski, Michael; Miller, Christopher J.

    2011-01-01

    In 2 meta-analyses involving 58 studies and 59,575 participants, we quantitatively summarized the relative reliability and validity of continuous (i.e., dimensional) and discrete (i.e., categorical) measures of psychopathology. Overall, results suggest an expected 15% increase in reliability and 37% increase in validity through adoption of a…

  2. Formation resistivity measurements from within a cased well used to quantitatively determine the amount of oil and gas present

    DOEpatents

    Vail, W.B. III

    1997-05-27

    Methods to quantitatively determine the separate amounts of oil and gas in a geological formation adjacent to a cased well using measurements of formation resistivity are disclosed. The steps include obtaining resistivity measurements from within a cased well of a given formation, obtaining the porosity, obtaining the resistivity of formation water present, computing the combined amounts of oil and gas present using Archie`s Equations, determining the relative amounts of oil and gas present from measurements within a cased well, and then quantitatively determining the separate amounts of oil and gas present in the formation. 7 figs.

  3. Measurement of lung expansion with computed tomography and comparison with quantitative histology.

    PubMed

    Coxson, H O; Mayo, J R; Behzad, H; Moore, B J; Verburgt, L M; Staples, C A; Paré, P D; Hogg, J C

    1995-11-01

    The total and regional lung volumes were estimated from computed tomography (CT), and the pleural pressure gradient was determined by using the milliliters of gas per gram of tissue estimated from the X-ray attenuation values and the pressure-volume curve of the lung. The data show that CT accurately estimated the volume of the resected lobe but overestimated its weight by 24 +/- 19%. The volume of gas per gram of tissue was less in the gravity-dependent regions due to a pleural pressure gradient of 0.24 +/- 0.08 cmH2O/cm of descent in the thorax. The proportion of tissue to air obtained with CT was similar to that obtained by quantitative histology. We conclude that the CT scan can be used to estimate total and regional lung volumes and that measurements of the proportions of tissue and air within the thorax by CT can be used in conjunction with quantitative histology to evaluate lung structure.

  4. Quantitative measurements of nanoscale permittivity and conductivity using tuning-fork-based microwave impedance microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Xiaoyu; Hao, Zhenqi; Wu, Di

    Here, we report quantitative measurements of nanoscale permittivity and conductivity using tuning-fork (TF) based microwave impedance microscopy (MIM). The system is operated under the driving amplitude modulation mode, which ensures satisfactory feedback stability on samples with rough surfaces. The demodulated MIM signals on a series of bulk dielectrics are in good agreement with results simulated by finite-element analysis. Using the TF-MIM, we have visualized the evolution of nanoscale conductance on back-gated MoS 2 field effect transistors, and the results are consistent with the transport data. Our work suggests that quantitative analysis of mesoscopic electrical properties can be achieved by near-fieldmore » microwave imaging with small distance modulation.« less

  5. Quantitative measurements of nanoscale permittivity and conductivity using tuning-fork-based microwave impedance microscopy

    DOE PAGES

    Wu, Xiaoyu; Hao, Zhenqi; Wu, Di; ...

    2018-04-01

    Here, we report quantitative measurements of nanoscale permittivity and conductivity using tuning-fork (TF) based microwave impedance microscopy (MIM). The system is operated under the driving amplitude modulation mode, which ensures satisfactory feedback stability on samples with rough surfaces. The demodulated MIM signals on a series of bulk dielectrics are in good agreement with results simulated by finite-element analysis. Using the TF-MIM, we have visualized the evolution of nanoscale conductance on back-gated MoS 2 field effect transistors, and the results are consistent with the transport data. Our work suggests that quantitative analysis of mesoscopic electrical properties can be achieved by near-fieldmore » microwave imaging with small distance modulation.« less

  6. Quantitative MRI and strength measurements in the assessment of muscle quality in Duchenne muscular dystrophy.

    PubMed

    Wokke, B H; van den Bergen, J C; Versluis, M J; Niks, E H; Milles, J; Webb, A G; van Zwet, E W; Aartsma-Rus, A; Verschuuren, J J; Kan, H E

    2014-05-01

    The purpose of this study was to assess leg muscle quality and give a detailed description of leg muscle involvement in a series of Duchenne muscular dystrophy patients using quantitative MRI and strength measurements. Fatty infiltration, as well as total and contractile (not fatty infiltrated) cross sectional areas of various leg muscles were determined in 16 Duchenne patients and 11 controls (aged 8-15). To determine specific muscle strength, four leg muscle groups (quadriceps femoris, hamstrings, anterior tibialis and triceps surae) were measured and related to the amount of contractile tissue. In patients, the quadriceps femoris showed decreased total and contractile cross sectional area, attributable to muscle atrophy. The total, but not the contractile, cross sectional area of the triceps surae was increased in patients, corresponding to hypertrophy. Specific strength decreased in all four muscle groups of Duchenne patients, indicating reduced muscle quality. This suggests that muscle hypertrophy and fatty infiltration are two distinct pathological processes, differing between muscle groups. Additionally, the quality of remaining muscle fibers is severely reduced in the legs of Duchenne patients. The combination of quantitative MRI and quantitative muscle testing could be a valuable outcome parameter in longitudinal studies and in the follow-up of therapeutic effects. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Quantitative Method of Measuring Metastatic Activity

    NASA Technical Reports Server (NTRS)

    Morrison, Dennis R. (Inventor)

    1999-01-01

    The metastatic potential of tumors can be evaluated by the quantitative detection of urokinase and DNA. The cell sample selected for examination is analyzed for the presence of high levels of urokinase and abnormal DNA using analytical flow cytometry and digital image analysis. Other factors such as membrane associated uroldnase, increased DNA synthesis rates and certain receptors can be used in the method for detection of potentially invasive tumors.

  8. The predictive value of quantitative fibronectin testing in combination with cervical length measurement in symptomatic women.

    PubMed

    Bruijn, Merel M C; Kamphuis, Esme I; Hoesli, Irene M; Martinez de Tejada, Begoña; Loccufier, Anne R; Kühnert, Maritta; Helmer, Hanns; Franz, Marie; Porath, Martina M; Oudijk, Martijn A; Jacquemyn, Yves; Schulzke, Sven M; Vetter, Grit; Hoste, Griet; Vis, Jolande Y; Kok, Marjolein; Mol, Ben W J; van Baaren, Gert-Jan

    2016-12-01

    The combination of the qualitative fetal fibronectin test and cervical length measurement has a high negative predictive value for preterm birth within 7 days; however, positive prediction is poor. A new bedside quantitative fetal fibronectin test showed potential additional value over the conventional qualitative test, but there is limited evidence on the combination with cervical length measurement. The purpose of this study was to compare quantitative fetal fibronectin and qualitative fetal fibronectin testing in the prediction of spontaneous preterm birth within 7 days in symptomatic women who undergo cervical length measurement. We performed a European multicenter cohort study in 10 perinatal centers in 5 countries. Women between 24 and 34 weeks of gestation with signs of active labor and intact membranes underwent quantitative fibronectin testing and cervical length measurement. We assessed the risk of preterm birth within 7 days in predefined strata based on fibronectin concentration and cervical length. Of 455 women who were included in the study, 48 women (11%) delivered within 7 days. A combination of cervical length and qualitative fibronectin resulted in the identification of 246 women who were at low risk: 164 women with a cervix between 15 and 30 mm and a negative fibronectin test (<50 ng/mL; preterm birth rate, 2%) and 82 women with a cervix at >30 mm (preterm birth rate, 2%). Use of quantitative fibronectin alone resulted in a predicted risk of preterm birth within 7 days that ranged from 2% in the group with the lowest fibronectin level (<10 ng/mL) to 38% in the group with the highest fibronectin level (>500 ng/mL), with similar accuracy as that of the combination of cervical length and qualitative fibronectin. Combining cervical length and quantitative fibronectin resulted in the identification of an additional 19 women at low risk (preterm birth rate, 5%), using a threshold of 10 ng/mL in women with a cervix at <15 mm, and 6 women at high risk

  9. Validation of a Spectral Method for Quantitative Measurement of Color in Protein Drug Solutions.

    PubMed

    Yin, Jian; Swartz, Trevor E; Zhang, Jian; Patapoff, Thomas W; Chen, Bartolo; Marhoul, Joseph; Shih, Norman; Kabakoff, Bruce; Rahimi, Kimia

    2016-01-01

    A quantitative spectral method has been developed to precisely measure the color of protein solutions. In this method, a spectrophotometer is utilized for capturing the visible absorption spectrum of a protein solution, which can then be converted to color values (L*a*b*) that represent human perception of color in a quantitative three-dimensional space. These quantitative values (L*a*b*) allow for calculating the best match of a sample's color to a European Pharmacopoeia reference color solution. In order to qualify this instrument and assay for use in clinical quality control, a technical assessment was conducted to evaluate the assay suitability and precision. Setting acceptance criteria for this study required development and implementation of a unique statistical method for assessing precision in 3-dimensional space. Different instruments, cuvettes, protein solutions, and analysts were compared in this study. The instrument accuracy, repeatability, and assay precision were determined. The instrument and assay are found suitable for use in assessing color of drug substances and drug products and is comparable to the current European Pharmacopoeia visual assessment method. In the biotechnology industry, a visual assessment is the most commonly used method for color characterization, batch release, and stability testing of liquid protein drug solutions. Using this method, an analyst visually determines the color of the sample by choosing the closest match to a standard color series. This visual method can be subjective because it requires an analyst to make a judgment of the best match of color of the sample to the standard color series, and it does not capture data on hue and chroma that would allow for improved product characterization and the ability to detect subtle differences between samples. To overcome these challenges, we developed a quantitative spectral method for color determination that greatly reduces the variability in measuring color and allows

  10. Measuring changes in transmission of neglected tropical diseases, malaria, and enteric pathogens from quantitative antibody levels

    PubMed Central

    van der Laan, Mark J.; Hubbard, Alan E.; Steel, Cathy; Kubofcik, Joseph; Hamlin, Katy L.; Moss, Delynn M.; Nutman, Thomas B.; Priest, Jeffrey W.; Lammie, Patrick J.

    2017-01-01

    Background Serological antibody levels are a sensitive marker of pathogen exposure, and advances in multiplex assays have created enormous potential for large-scale, integrated infectious disease surveillance. Most methods to analyze antibody measurements reduce quantitative antibody levels to seropositive and seronegative groups, but this can be difficult for many pathogens and may provide lower resolution information than quantitative levels. Analysis methods have predominantly maintained a single disease focus, yet integrated surveillance platforms would benefit from methodologies that work across diverse pathogens included in multiplex assays. Methods/Principal findings We developed an approach to measure changes in transmission from quantitative antibody levels that can be applied to diverse pathogens of global importance. We compared age-dependent immunoglobulin G curves in repeated cross-sectional surveys between populations with differences in transmission for multiple pathogens, including: lymphatic filariasis (Wuchereria bancrofti) measured before and after mass drug administration on Mauke, Cook Islands, malaria (Plasmodium falciparum) before and after a combined insecticide and mass drug administration intervention in the Garki project, Nigeria, and enteric protozoans (Cryptosporidium parvum, Giardia intestinalis, Entamoeba histolytica), bacteria (enterotoxigenic Escherichia coli, Salmonella spp.), and viruses (norovirus groups I and II) in children living in Haiti and the USA. Age-dependent antibody curves fit with ensemble machine learning followed a characteristic shape across pathogens that aligned with predictions from basic mechanisms of humoral immunity. Differences in pathogen transmission led to shifts in fitted antibody curves that were remarkably consistent across pathogens, assays, and populations. Mean antibody levels correlated strongly with traditional measures of transmission intensity, such as the entomological inoculation rate for P

  11. Quantitative method for measuring heat flux emitted from a cryogenic object

    DOEpatents

    Duncan, Robert V.

    1993-01-01

    The present invention is a quantitative method for measuring the total heat flux, and of deriving the total power dissipation, of a heat-fluxing object which includes the steps of placing an electrical noise-emitting heat-fluxing object in a liquid helium bath and measuring the superfluid transition temperature of the bath. The temperature of the liquid helium bath is thereafter reduced until some measurable parameter, such as the electrical noise, exhibited by the heat-fluxing object or a temperature-dependent resistive thin film in intimate contact with the heat-fluxing object, becomes greatly reduced. The temperature of the liquid helum bath is measured at this point. The difference between the superfluid transition temperature of the liquid helium bath surrounding the heat-fluxing object, and the temperature of the liquid helium bath when the electrical noise emitted by the heat-fluxing object becomes greatly reduced, is determined. The total heat flux from the heat-fluxing object is determined as a function of this difference between these temperatures. In certain applications, the technique can be used to optimize thermal design parameters of cryogenic electronics, for example, Josephson junction and infra-red sensing devices.

  12. Quantitative method for measuring heat flux emitted from a cryogenic object

    DOEpatents

    Duncan, R.V.

    1993-03-16

    The present invention is a quantitative method for measuring the total heat flux, and of deriving the total power dissipation, of a heat-fluxing object which includes the steps of placing an electrical noise-emitting heat-fluxing object in a liquid helium bath and measuring the superfluid transition temperature of the bath. The temperature of the liquid helium bath is thereafter reduced until some measurable parameter, such as the electrical noise, exhibited by the heat-fluxing object or a temperature-dependent resistive thin film in intimate contact with the heat-fluxing object, becomes greatly reduced. The temperature of the liquid helum bath is measured at this point. The difference between the superfluid transition temperature of the liquid helium bath surrounding the heat-fluxing object, and the temperature of the liquid helium bath when the electrical noise emitted by the heat-fluxing object becomes greatly reduced, is determined. The total heat flux from the heat-fluxing object is determined as a function of this difference between these temperatures. In certain applications, the technique can be used to optimize thermal design parameters of cryogenic electronics, for example, Josephson junction and infrared sensing devices.

  13. Quantitative measurement of piezoelectric coefficient of thin film using a scanning evanescent microwave microscope.

    PubMed

    Zhao, Zhenli; Luo, Zhenlin; Liu, Chihui; Wu, Wenbin; Gao, Chen; Lu, Yalin

    2008-06-01

    This article describes a new approach to quantitatively measure the piezoelectric coefficients of thin films at the microscopic level using a scanning evanescent microwave microscope. This technique can resolve 10 pm deformation caused by the piezoelectric effect and has the advantages of high scanning speed, large scanning area, submicron spatial resolution, and a simultaneous accessibility to many other related properties. Results from the test measurements on the longitudinal piezoelectric coefficient of PZT thin film agree well with those from other techniques listed in literatures.

  14. A specialized plug-in software module for computer-aided quantitative measurement of medical images.

    PubMed

    Wang, Q; Zeng, Y J; Huo, P; Hu, J L; Zhang, J H

    2003-12-01

    This paper presents a specialized system for quantitative measurement of medical images. Using Visual C++, we developed a computer-aided software based on Image-Pro Plus (IPP), a software development platform. When transferred to the hard disk of a computer by an MVPCI-V3A frame grabber, medical images can be automatically processed by our own IPP plug-in for immunohistochemical analysis, cytomorphological measurement and blood vessel segmentation. In 34 clinical studies, the system has shown its high stability, reliability and ease of utility.

  15. Measuring Filament Orientation: A New Quantitative, Local Approach

    NASA Astrophysics Data System (ADS)

    Green, C.-E.; Dawson, J. R.; Cunningham, M. R.; Jones, P. A.; Novak, G.; Fissel, L. M.

    2017-09-01

    The relative orientation between filamentary structures in molecular clouds and the ambient magnetic field provides insight into filament formation and stability. To calculate the relative orientation, a measurement of filament orientation is first required. We propose a new method to calculate the orientation of the one-pixel-wide filament skeleton that is output by filament identification algorithms such as filfinder. We derive the local filament orientation from the direction of the intensity gradient in the skeleton image using the Sobel filter and a few simple post-processing steps. We call this the “Sobel-gradient method.” The resulting filament orientation map can be compared quantitatively on a local scale with the magnetic field orientation map to then find the relative orientation of the filament with respect to the magnetic field at each point along the filament. It can also be used for constructing radial profiles for filament width fitting. The proposed method facilitates automation in analyses of filament skeletons, which is imperative in this era of “big data.”

  16. Standardized Approach to Quantitatively Measure Residual Limb Skin Health in Individuals with Lower Limb Amputation.

    PubMed

    Rink, Cameron L; Wernke, Matthew M; Powell, Heather M; Tornero, Mark; Gnyawali, Surya C; Schroeder, Ryan M; Kim, Jayne Y; Denune, Jeffrey A; Albury, Alexander W; Gordillo, Gayle M; Colvin, James M; Sen, Chandan K

    2017-07-01

    Objective: (1) Develop a standardized approach to quantitatively measure residual limb skin health. (2) Report reference residual limb skin health values in people with transtibial and transfemoral amputation. Approach: Residual limb health outcomes in individuals with transtibial ( n  = 5) and transfemoral ( n  = 5) amputation were compared to able-limb controls ( n  = 4) using noninvasive imaging (hyperspectral imaging and laser speckle flowmetry) and probe-based approaches (laser doppler flowmetry, transcutaneous oxygen, transepidermal water loss, surface electrical capacitance). Results: A standardized methodology that employs noninvasive imaging and probe-based approaches to measure residual limb skin health are described. Compared to able-limb controls, individuals with transtibial and transfemoral amputation have significantly lower transcutaneous oxygen tension, higher transepidermal water loss, and higher surface electrical capacitance in the residual limb. Innovation: Residual limb health as a critical component of prosthesis rehabilitation for individuals with lower limb amputation is understudied in part due to a lack of clinical measures. Here, we present a standardized approach to measure residual limb health in people with transtibial and transfemoral amputation. Conclusion: Technology advances in noninvasive imaging and probe-based measures are leveraged to develop a standardized approach to quantitatively measure residual limb health in individuals with lower limb loss. Compared to able-limb controls, resting residual limb physiology in people that have had transfemoral or transtibial amputation is characterized by lower transcutaneous oxygen tension and poorer skin barrier function.

  17. The measurement of liver fat from single-energy quantitative computed tomography scans

    PubMed Central

    Cheng, Xiaoguang; Brown, J. Keenan; Guo, Zhe; Zhou, Jun; Wang, Fengzhe; Yang, Liqiang; Wang, Xiaohong; Xu, Li

    2017-01-01

    Background Studies of soft tissue composition using computed tomography (CT) scans are often semi-quantitative and based on Hounsfield units (HU) measurements that have not been calibrated with a quantitative CT (QCT) phantom. We describe a study to establish the water (H2O) and dipotassium hydrogen phosphate (K2HPO4) basis set equivalent densities of fat and fat-free liver tissue. With this information liver fat can be accurately measured from any abdominal CT scan calibrated with a suitable phantom. Methods Liver fat content was measured by comparing single-energy QCT (SEQCT) HU measurements of the liver with predicted HU values for fat and fat-free liver tissue calculated from their H2O and K2HPO4 equivalent densities and calibration data from a QCT phantom. The equivalent densities of fat were derived from a listing of its constituent fatty acids, and those of fat-free liver tissue from a dual-energy QCT (DEQCT) study performed in 14 healthy Chinese subjects. This information was used to calculate liver fat from abdominal SEQCT scans performed in a further 541 healthy Chinese subjects (mean age 62 years; range, 31–95 years) enrolled in the Prospective Urban Rural Epidemiology (PURE) Study. Results The equivalent densities of fat were 941.75 mg/cm3 H2O and –43.72 mg/cm3 K2HPO4, and for fat-free liver tissue 1,040.13 mg/cm3 H2O and 21.34 mg/cm3 K2HPO4. Liver fat in the 14 subjects in the DEQCT study varied from 0–17.9% [median: 4.5%; interquartile range (IQR): 3.0–7.9%]. Liver fat in the 541 PURE study subjects varied from –0.3–29.9% (median: 4.9%; IQR: 3.4–6.9%). Conclusions We have established H2O and K2HPO4 equivalent densities for fat and fat-free liver tissue that allow a measurement of liver fat to be obtained from any abdominal CT scan acquired with a QCT phantom. Although radiation dose considerations preclude the routine use of QCT to measure liver fat, the method described here facilitates its measurement in patients having CT scans

  18. Mid-infrared laser absorption tomography for quantitative 2D thermochemistry measurements in premixed jet flames

    NASA Astrophysics Data System (ADS)

    Wei, Chuyu; Pineda, Daniel I.; Paxton, Laurel; Egolfopoulos, Fokion N.; Spearrin, R. Mitchell

    2018-06-01

    A tomographic laser absorption spectroscopy technique, utilizing mid-infrared light sources, is presented as a quantitative method to spatially resolve species and temperature profiles in small-diameter reacting flows relevant to combustion systems. Here, tunable quantum and interband cascade lasers are used to spectrally resolve select rovibrational transitions near 4.98 and 4.19 μm to measure CO and {CO2}, respectively, as well as their vibrational temperatures, in piloted premixed jet flames. Signal processing methods are detailed for the reconstruction of axial and radial profiles of thermochemical structure in a canonical ethylene-air jet flame. The method is further demonstrated to quantitatively distinguish between different turbulent flow conditions.

  19. Numerical analysis of quantitative measurement of hydroxyl radical concentration using laser-induced fluorescence in flame

    NASA Astrophysics Data System (ADS)

    Shuang, Chen; Tie, Su; Yao-Bang, Zheng; Li, Chen; Ting-Xu, Liu; Ren-Bing, Li; Fu-Rong, Yang

    2016-06-01

    The aim of the present work is to quantitatively measure the hydroxyl radical concentration by using LIF (laser-induced fluorescence) in flame. The detailed physical models of spectral absorption lineshape broadening, collisional transition and quenching at elevated pressure are built. The fine energy level structure of the OH molecule is illustrated to understand the process with laser-induced fluorescence emission and others in the case without radiation, which include collisional quenching, rotational energy transfer (RET), and vibrational energy transfer (VET). Based on these, some numerical results are achieved by simulations in order to evaluate the fluorescence yield at elevated pressure. These results are useful for understanding the real physical processes in OH-LIF technique and finding a way to calibrate the signal for quantitative measurement of OH concentration in a practical combustor. Project supported by the National Natural Science Foundation of China (Grant No. 11272338) and the Fund from the Science and Technology on Scramjet Key Laboratory, China (Grant No. STSKFKT2013004).

  20. Quantitative flow and velocity measurements of pulsatile blood flow with 4D-DSA

    NASA Astrophysics Data System (ADS)

    Shaughnessy, Gabe; Hoffman, Carson; Schafer, Sebastian; Mistretta, Charles A.; Strother, Charles M.

    2017-03-01

    Time resolved 3D angiographic data from 4D DSA provides a unique environment to explore physical properties of blood flow. Utilizing the pulsatility of the contrast waveform, the Fourier components can be used to track the waveform motion through vessels. Areas of strong pulsatility are determined through the FFT power spectrum. Using this method, we find an accuracy from 4D-DSA flow measurements within 7.6% and 6.8% RMSE of ICA PCVIPR and phantom flow probe validation measurements, respectively. The availability of velocity and flow information with fast acquisition could provide a more quantitative approach to treatment planning and evaluation in interventional radiology.

  1. A quantitative evaluation of spurious results in the infrared spectroscopic measurement of CO2 isotope ratios

    NASA Astrophysics Data System (ADS)

    Mansfield, C. D.; Rutt, H. N.

    2002-02-01

    The possible generation of spurious results, arising from the application of infrared spectroscopic techniques to the measurement of carbon isotope ratios in breath, due to coincident absorption bands has been re-examined. An earlier investigation, which approached the problem qualitatively, fulfilled its aspirations in providing an unambiguous assurance that 13C16O2/12C16O2 ratios can be confidently measured for isotopic breath tests using instruments based on infrared absorption. Although this conclusion still stands, subsequent quantitative investigation has revealed an important exception that necessitates a strict adherence to sample collection protocol. The results show that concentrations and decay rates of the coincident breath trace compounds acetonitrile and carbon monoxide, found in the breath sample of a heavy smoker, can produce spurious results. Hence, findings from this investigation justify the concern that breath trace compounds present a risk to the accurate measurement of carbon isotope ratios in breath when using broadband, non-dispersive, ground state absorption infrared spectroscopy. It provides recommendations on the length of smoking abstention required to avoid generation of spurious results and also reaffirms, through quantitative argument, the validity of using infrared absorption spectroscopy to measure CO2 isotope ratios in breath.

  2. Nanoscale Structure of Type I Collagen Fibrils: Quantitative Measurement of D-spacing

    PubMed Central

    Erickson, Blake; Fang, Ming; Wallace, Joseph M.; Orr, Bradford G.; Les, Clifford M.; Holl, Mark M. Banaszak

    2012-01-01

    This paper details a quantitative method to measure the D-periodic spacing of Type I collagen fibrils using Atomic Force Microscopy coupled with analysis using a 2D Fast Fourier Transform approach. Instrument calibration, data sampling and data analysis are all discussed and comparisons of the data to the complementary methods of electron microscopy and X-ray scattering are made. Examples of the application of this new approach to the analysis of Type I collagen morphology in disease models of estrogen depletion and Osteogenesis Imperfecta are provided. We demonstrate that it is the D-spacing distribution, not the D-spacing mean, that showed statistically significant differences in estrogen depletion associated with early stage Osteoporosis and Osteogenesis Imperfecta. The ability to quantitatively characterize nanoscale morphological features of Type I collagen fibrils will provide important structural information regarding Type I collagen in many research areas, including tissue aging and disease, tissue engineering, and gene knock out studies. Furthermore, we also envision potential clinical applications including evaluation of tissue collagen integrity under the impact of diseases or drug treatments. PMID:23027700

  3. Initial description of a quantitative, cross-species (chimpanzee-human) social responsiveness measure

    PubMed Central

    Marrus, Natasha; Faughn, Carley; Shuman, Jeremy; Petersen, Steve; Constantino, John; Povinelli, Daniel; Pruett, John R.

    2011-01-01

    Objective Comparative studies of social responsiveness, an ability that is impaired in autistic spectrum disorders, can inform our understanding of both autism and the cognitive architecture of social behavior. Because there is no existing quantitative measure of social responsiveness in chimpanzees, we generated a quantitative, cross-species (human-chimpanzee) social responsiveness measure. Method We translated the Social Responsiveness Scale (SRS), an instrument that quantifies human social responsiveness, into an analogous instrument for chimpanzees. We then retranslated this "Chimp SRS" into a human "Cross-Species SRS" (XSRS). We evaluated three groups of chimpanzees (n=29) with the Chimp SRS and typical and autistic spectrum disorder (ASD) human children (n=20) with the XSRS. Results The Chimp SRS demonstrated strong inter-rater reliability at the three sites (ranges for individual ICCs: .534–.866 and mean ICCs: .851–.970). As has been observed in humans, exploratory principal components analysis of Chimp SRS scores supports a single factor underlying chimpanzee social responsiveness. Human subjects' XSRS scores were fully concordant with their SRS scores (r=.976, p=.001) and distinguished appropriately between typical and ASD subjects. One chimpanzee known for inappropriate social behavior displayed a significantly higher score than all other chimpanzees at its site, demonstrating the scale's ability to detect impaired social responsiveness in chimpanzees. Conclusion Our initial cross-species social responsiveness scale proved reliable and discriminated differences in social responsiveness across (in a relative sense) and within (in a more objectively quantifiable manner) humans and chimpanzees. PMID:21515200

  4. Resected Brain Tissue, Seizure Onset Zone and Quantitative EEG Measures: Towards Prediction of Post-Surgical Seizure Control

    PubMed Central

    Andrzejak, Ralph G.; Hauf, Martinus; Pollo, Claudio; Müller, Markus; Weisstanner, Christian; Wiest, Roland; Schindler, Kaspar

    2015-01-01

    Background Epilepsy surgery is a potentially curative treatment option for pharmacoresistent patients. If non-invasive methods alone do not allow to delineate the epileptogenic brain areas the surgical candidates undergo long-term monitoring with intracranial EEG. Visual EEG analysis is then used to identify the seizure onset zone for targeted resection as a standard procedure. Methods Despite of its great potential to assess the epileptogenicty of brain tissue, quantitative EEG analysis has not yet found its way into routine clinical practice. To demonstrate that quantitative EEG may yield clinically highly relevant information we retrospectively investigated how post-operative seizure control is associated with four selected EEG measures evaluated in the resected brain tissue and the seizure onset zone. Importantly, the exact spatial location of the intracranial electrodes was determined by coregistration of pre-operative MRI and post-implantation CT and coregistration with post-resection MRI was used to delineate the extent of tissue resection. Using data-driven thresholding, quantitative EEG results were separated into normally contributing and salient channels. Results In patients with favorable post-surgical seizure control a significantly larger fraction of salient channels in three of the four quantitative EEG measures was resected than in patients with unfavorable outcome in terms of seizure control (median over the whole peri-ictal recordings). The same statistics revealed no association with post-operative seizure control when EEG channels contributing to the seizure onset zone were studied. Conclusions We conclude that quantitative EEG measures provide clinically relevant and objective markers of target tissue, which may be used to optimize epilepsy surgery. The finding that differentiation between favorable and unfavorable outcome was better for the fraction of salient values in the resected brain tissue than in the seizure onset zone is consistent

  5. Introduction of an automated user-independent quantitative volumetric magnetic resonance imaging breast density measurement system using the Dixon sequence: comparison with mammographic breast density assessment.

    PubMed

    Wengert, Georg Johannes; Helbich, Thomas H; Vogl, Wolf-Dieter; Baltzer, Pascal; Langs, Georg; Weber, Michael; Bogner, Wolfgang; Gruber, Stephan; Trattnig, Siegfried; Pinker, Katja

    2015-02-01

    The purposes of this study were to introduce and assess an automated user-independent quantitative volumetric (AUQV) breast density (BD) measurement system on the basis of magnetic resonance imaging (MRI) using the Dixon technique as well as to compare it with qualitative and quantitative mammographic (MG) BD measurements. Forty-three women with normal mammogram results (Breast Imaging Reporting and Data System 1) were included in this institutional review board-approved prospective study. All participants were subjected to BD assessment with MRI using the following sequence with the Dixon technique (echo time/echo time, 6 milliseconds/2.45 milliseconds/2.67 milliseconds; 1-mm isotropic; 3 minutes 38 seconds). To test the reproducibility, a second MRI after patient repositioning was performed. The AUQV magnetic resonance (MR) BD measurement system automatically calculated percentage (%) BD. The qualitative BD assessment was performed using the American College of Radiology Breast Imaging Reporting and Data System BD categories. Quantitative BD was estimated semiautomatically using the thresholding technique Cumulus4. Appropriate statistical tests were used to assess the agreement between the AUQV MR measurements and to compare them with qualitative and quantitative MG BD estimations. The AUQV MR BD measurements were successfully performed in all 43 women. There was a nearly perfect agreement of AUQV MR BD measurements between the 2 MR examinations for % BD (P < 0.001; intraclass correlation coefficient, 0.998) with no significant differences (P = 0.384). The AUQV MR BD measurements were significantly lower than quantitative and qualitative MG BD assessment (P < 0.001). The AUQV MR BD measurement system allows a fully automated, user-independent, robust, reproducible, as well as radiation- and compression-free volumetric quantitative BD assessment through different levels of BD. The AUQV MR BD measurements were significantly lower than the currently used qualitative

  6. Formation resistivity measurements from within a cased well used to quantitatively determine the amount of oil and gas present

    DOEpatents

    Vail, III, William Banning

    2000-01-01

    Methods to quantitatively determine the separate amounts of oil and gas in a geological formation adjacent to a cased well using measurements of formation resistivity. The steps include obtaining resistivity measurements from within a cased well of a given formation, obtaining the porosity, obtaining the resistivity of formation water present, computing the combined amounts of oil and gas present using Archie's Equations, determining the relative amounts of oil and gas present from measurements within a cased well, and then quantitatively determining the separate amounts of oil and gas present in the formation. Resistivity measurements are obtained from within the cased well by conducting A.C. current from within the cased well to a remote electrode at a frequency that is within the frequency range of 0.1 Hz to 20 Hz.

  7. OPPORTUNISTIC ASPERGILLUS PATHOGENS MEASURED IN HOME AND HOSPITAL TAP WATER BY MOLD SPECIFIC QUANTITATIVE PCR (MSQPCR)

    EPA Science Inventory

    Opportunistic fungal pathogens are a concern because of the increasing number of immunocompromised patients. The goal of this research was to test a simple extraction method and rapid quantitative PCR (QPCR) measurement of the occurrence of potential pathogens, Aspergillus fumiga...

  8. Advances in Surface Plasmon Resonance Imaging allowing for quantitative measurement of laterally heterogeneous samples

    NASA Astrophysics Data System (ADS)

    Raegen, Adam; Reiter, Kyle; Clarke, Anthony; Lipkowski, Jacek; Dutcher, John

    2012-02-01

    The Surface Plasmon Resonance (SPR) phenomenon is routinely exploited to qualitatively probe changes to materials on metallic surfaces for use in probes and sensors. Unfortunately, extracting truly quantitative information is usually limited to a select few cases -- uniform absorption/desorption of small biomolecules and films, in which a continuous ``slab'' model is a good approximation. We present advancements in the SPR technique that expand the number of cases for which the technique can provide meaningful results. Use of a custom, angle-scanning SPR imaging system, together with a refined data analysis method, allow for quantitative kinetic measurements of laterally heterogeneous systems. The degradation of cellulose microfibrils and bundles of microfibrils due to the action of cellulolytic enzymes will be presented as an excellent example of the capabilities of the SPR imaging system.

  9. Quantitative Measures of Immersion in Cloud and the Biogeography of Cloud Forests

    NASA Technical Reports Server (NTRS)

    Lawton, R. O.; Nair, U. S.; Ray, D.; Regmi, A.; Pounds, J. A.; Welch, R. M.

    2010-01-01

    Sites described as tropical montane cloud forests differ greatly, in part because observers tend to differ in their opinion as to what constitutes frequent and prolonged immersion in cloud. This definitional difficulty interferes with hydrologic analyses, assessments of environmental impacts on ecosystems, and biogeographical analyses of cloud forest communities and species. Quantitative measurements of cloud immersion can be obtained on site, but the observations are necessarily spatially limited, although well-placed observers can examine 10 50 km of a mountain range under rainless conditions. Regional analyses, however, require observations at a broader scale. This chapter discusses remote sensing and modeling approaches that can provide quantitative measures of the spatiotemporal patterns of cloud cover and cloud immersion in tropical mountain ranges. These approaches integrate remote sensing tools of various spatial resolutions and frequencies of observation, digital elevation models, regional atmospheric models, and ground-based observations to provide measures of cloud cover, cloud base height, and the intersection of cloud and terrain. This combined approach was applied to the Monteverde region of northern Costa Rica to illustrate how the proportion of time the forest is immersed in cloud may vary spatially and temporally. The observed spatial variation was largely due to patterns of airflow over the mountains. The temporal variation reflected the diurnal rise and fall of the orographic cloud base, which was influenced in turn by synoptic weather conditions, the seasonal movement of the Intertropical Convergence Zone and the north-easterly trade winds. Knowledge of the proportion of the time that sites are immersed in clouds should facilitate ecological comparisons and biogeographical analyses, as well as land use planning and hydrologic assessments in areas where intensive on-site work is not feasible.

  10. Correlation of 125I-LSD autoradiographic labeling with serotonin voltage clamp responses in Aplysia neurons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evans, M.L.; Kadan, M.J.; Hartig, P.R.

    Autoradiographic receptor binding studies using 125I-LSD (2-(125I)lysergic acid diethyamide) revealed intense labelling on the soma of a symmetrically located pair of cells in the abdominal ganglion of Aplysia californica. This binding was blocked by micromolar concentrations of serotonin and lower concentrations of the serotonergic antagonists, cyproheptadine and mianserin. Electrophysiological investigation of responses to serotonin of neurons in the left upper quadrant, where one of the labeled neurons is located, revealed a range of serotonin responses. Cells L3 and L6 have a K+ conductance increase in response to serotonin that is not blocked by cyproheptadine or mianserin. Cells L2 and L4more » have a biphasic response to serotonin: a Na+ conductance increase, which can be blocked by cyproheptadine and mianserin, followed by a voltage dependent Ca2+ conductance which is blocked by Co2+ but not the serotonergic antagonists. Cell L1, and its symmetrical pair, R1, have in addition to the Na+ and Ca2+ responses observed in L2 and L4, a Cl- conductance increase blocked by LSD, cyproheptadine and mianserin. LSD had little effect on the other responses. The authors conclude that the symmetrically located cells L1 and R1 have a Cl- channel linked to a cyproheptadine- and mianserin-sensitive serotonin receptor that is selectively labelled by 125I-LSD. This receptor has many properties in common with the mammalian serotonin 1C receptor.« less

  11. A device for rapid and quantitative measurement of cardiac myocyte contractility

    NASA Astrophysics Data System (ADS)

    Gaitas, Angelo; Malhotra, Ricky; Li, Tao; Herron, Todd; Jalife, José

    2015-03-01

    Cardiac contractility is the hallmark of cardiac function and is a predictor of healthy or diseased cardiac muscle. Despite advancements over the last two decades, the techniques and tools available to cardiovascular scientists are limited in their utility to accurately and reliably measure the amplitude and frequency of cardiomyocyte contractions. Isometric force measurements in the past have entailed cumbersome attachment of isolated and permeabilized cardiomyocytes to a force transducer followed by measurements of sarcomere lengths under conditions of submaximal and maximal Ca2+ activation. These techniques have the inherent disadvantages of being labor intensive and costly. We have engineered a micro-machined cantilever sensor with an embedded deflection-sensing element that, in preliminary experiments, has demonstrated to reliably measure cardiac cell contractions in real-time. Here, we describe this new bioengineering tool with applicability in the cardiovascular research field to effectively and reliably measure cardiac cell contractility in a quantitative manner. We measured contractility in both primary neonatal rat heart cardiomyocyte monolayers that demonstrated a beat frequency of 3 Hz as well as human embryonic stem cell-derived cardiomyocytes with a contractile frequency of about 1 Hz. We also employed the β-adrenergic agonist isoproterenol (100 nmol l-1) and observed that our cantilever demonstrated high sensitivity in detecting subtle changes in both chronotropic and inotropic responses of monolayers. This report describes the utility of our micro-device in both basic cardiovascular research as well as in small molecule drug discovery to monitor cardiac cell contractions.

  12. Development and psychometric evaluation of a quantitative measure of "fat talk".

    PubMed

    MacDonald Clarke, Paige; Murnen, Sarah K; Smolak, Linda

    2010-01-01

    Based on her anthropological research, Nichter (2000) concluded that it is normative for many American girls to engage in body self-disparagement in the form of "fat talk." The purpose of the present two studies was to develop a quantitative measure of fat talk. A series of 17 scenarios were created in which "Naomi" is talking with a female friend(s) and there is an expression of fat talk. College women respondents rated the frequency with which they would behave in a similar way as the women in each scenario. A nine-item one-factor scale was determined through principal components analysis and its scores yielded evidence of internal consistency reliability, test-retest reliability over a five-week time period, construct validity, discriminant validity, and incremental validity in that it predicted unique variance in body shame and eating disorder symptoms above and beyond other measures of self-objectification. Copyright 2009 Elsevier Ltd. All rights reserved.

  13. Selecting quantitative water management measures at the river basin scale in a global change context

    NASA Astrophysics Data System (ADS)

    Girard, Corentin; Rinaudo, Jean-Daniel; Caballero, Yvan; Pulido-Velazquez, Manuel

    2013-04-01

    One of the main challenges in the implementation of the Water Framework Directive (WFD) in the European Union is the definition of programme of measures to reach the good status of the European water bodies. In areas where water scarcity is an issue, one of these challenges is the selection of water conservation and capacity expansion measures to ensure minimum environmental in-stream flow requirements. At the same time, the WFD calls for the use of economic analysis to identify the most cost-effective combination of measures at the river basin scale to achieve its objective. With this respect, hydro-economic river basin models, by integrating economics, environmental and hydrological aspects at the river basin scale in a consistent framework, represent a promising approach. This article presents a least-cost river basin optimization model (LCRBOM) that selects the combination of quantitative water management measures to meet environmental flows for future scenarios of agricultural and urban demand taken into account the impact of the climate change. The model has been implemented in a case study on a Mediterranean basin in the south of France, the Orb River basin. The water basin has been identified as in need for quantitative water management measures in order to reach the good status of its water bodies. The LCRBOM has been developed using GAMS, applying Mixed Integer Linear Programming. It is run to select the set of measures that minimizes the total annualized cost of the applied measures, while meeting the demands and minimum in-stream flow constraints. For the economic analysis, the programme of measures is composed of water conservation measures on agricultural and urban water demands. It compares them with measures mobilizing new water resources coming from groundwater, inter-basin transfers and improvement in reservoir operating rules. The total annual cost of each measure is calculated for each demand unit considering operation, maintenance and

  14. Autoradiographic analysis of the in vivo distribution of 3H-imipramine and 3H-desipramine in brain: Comparison to in vitro binding patterns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duncan, G.E.; Paul, I.A.; Fassberg, J.B.

    1991-03-01

    Using high resolution autoradiographic techniques, the distribution of radioactivity in forebrain and brainstem was assessed after 4 injection of 3H-impramine or 3H-desipramine. Results were compared with regional binding of the drugs to brain sections in vitro. Similar topographic binding of 3H-imipramine and 3H-desipramine was observed in vitro among brain regions, except in the paraventricular nucleus of the hypothalamus and locus coeruleus, where binding was greater for 3H-desipramine. For both 3H-desipramine and 3H-imipramine, some brain regions that exhibited high binding in vitro also showed high accumulation after in vivo injection. However, certain regions that contained high densities of binding sites formore » the antidepressant drugs as measured by in vitro binding showed very low accumulation of radioactivity after in vivo treatment. Such regions included the dentate gyrus of the hippocampus, layer 1 of piriform cortex, caudate-putamen, pontine and midbrain central gray, and cerebellar granular layer. Compared to in vitro binding of the drugs, the distribution of imipramine and desipramine in vivo appears more anatomically selective. For imipramine, primary sites of action in vivo, as indicated by the topographic distribution in brain, appear to be the locus coeruleus, hippocampus, lateral septal nucleus, and amygdala. For desipramine, the greatest accumulation in vivo was found in the locus coeruleus, paraventricular nucleus of the hypothalamus, and anterior thalamic nuclei.« less

  15. Multisite concordance of apparent diffusion coefficient measurements across the NCI Quantitative Imaging Network.

    PubMed

    Newitt, David C; Malyarenko, Dariya; Chenevert, Thomas L; Quarles, C Chad; Bell, Laura; Fedorov, Andriy; Fennessy, Fiona; Jacobs, Michael A; Solaiyappan, Meiyappan; Hectors, Stefanie; Taouli, Bachir; Muzi, Mark; Kinahan, Paul E; Schmainda, Kathleen M; Prah, Melissa A; Taber, Erin N; Kroenke, Christopher; Huang, Wei; Arlinghaus, Lori R; Yankeelov, Thomas E; Cao, Yue; Aryal, Madhava; Yen, Yi-Fen; Kalpathy-Cramer, Jayashree; Shukla-Dave, Amita; Fung, Maggie; Liang, Jiachao; Boss, Michael; Hylton, Nola

    2018-01-01

    Diffusion weighted MRI has become ubiquitous in many areas of medicine, including cancer diagnosis and treatment response monitoring. Reproducibility of diffusion metrics is essential for their acceptance as quantitative biomarkers in these areas. We examined the variability in the apparent diffusion coefficient (ADC) obtained from both postprocessing software implementations utilized by the NCI Quantitative Imaging Network and online scan time-generated ADC maps. Phantom and in vivo breast studies were evaluated for two ([Formula: see text]) and four ([Formula: see text]) [Formula: see text]-value diffusion metrics. Concordance of the majority of implementations was excellent for both phantom ADC measures and in vivo [Formula: see text], with relative biases [Formula: see text] ([Formula: see text]) and [Formula: see text] (phantom [Formula: see text]) but with higher deviations in ADC at the lowest phantom ADC values. In vivo [Formula: see text] concordance was good, with typical biases of [Formula: see text] to 3% but higher for online maps. Multiple b -value ADC implementations were separated into two groups determined by the fitting algorithm. Intergroup mean ADC differences ranged from negligible for phantom data to 2.8% for [Formula: see text] in vivo data. Some higher deviations were found for individual implementations and online parametric maps. Despite generally good concordance, implementation biases in ADC measures are sometimes significant and may be large enough to be of concern in multisite studies.

  16. Quantitative measurement of adhesion of ink on plastic films with a Nano Indenter and a Scanning Probe Microscope

    NASA Astrophysics Data System (ADS)

    Shen, Weidian

    2005-03-01

    Plastic film packaging is widely used these days, especially in the convenience food industry due to its flexibility, boilability, and microwavability. Almost every package is printed with ink. The adhesion of ink on plastic films merits increasing attention to ensure quality packaging. However, inks and plastic films are polymeric materials with complicated molecular structures. The thickness of the jelly-like ink is only 500nm or less, and the thickness of the soft and flexible film is no more than 50μm, which make the quantitative measurement of their adhesion very challenging. Up to now, no scientific quantitative measurement method for the adhesion of ink on plastic films has been documented. We have tried a technique, in which a Nano-Indenter and a Scanning Probe Microscope were used to evaluate the adhesion strength of ink deposited on plastic films, quantitatively, as well as examine the configurations of adhesion failure. It was helpful in better understanding the adhesion mechanism, thus giving direction as to how to improve the adhesion.

  17. A novel method for morphological pleomorphism and heterogeneity quantitative measurement: Named cell feature level co-occurrence matrix.

    PubMed

    Saito, Akira; Numata, Yasushi; Hamada, Takuya; Horisawa, Tomoyoshi; Cosatto, Eric; Graf, Hans-Peter; Kuroda, Masahiko; Yamamoto, Yoichiro

    2016-01-01

    Recent developments in molecular pathology and genetic/epigenetic analysis of cancer tissue have resulted in a marked increase in objective and measurable data. In comparison, the traditional morphological analysis approach to pathology diagnosis, which can connect these molecular data and clinical diagnosis, is still mostly subjective. Even though the advent and popularization of digital pathology has provided a boost to computer-aided diagnosis, some important pathological concepts still remain largely non-quantitative and their associated data measurements depend on the pathologist's sense and experience. Such features include pleomorphism and heterogeneity. In this paper, we propose a method for the objective measurement of pleomorphism and heterogeneity, using the cell-level co-occurrence matrix. Our method is based on the widely used Gray-level co-occurrence matrix (GLCM), where relations between neighboring pixel intensity levels are captured into a co-occurrence matrix, followed by the application of analysis functions such as Haralick features. In the pathological tissue image, through image processing techniques, each nucleus can be measured and each nucleus has its own measureable features like nucleus size, roundness, contour length, intra-nucleus texture data (GLCM is one of the methods). In GLCM each nucleus in the tissue image corresponds to one pixel. In this approach the most important point is how to define the neighborhood of each nucleus. We define three types of neighborhoods of a nucleus, then create the co-occurrence matrix and apply Haralick feature functions. In each image pleomorphism and heterogeneity are then determined quantitatively. For our method, one pixel corresponds to one nucleus feature, and we therefore named our method Cell Feature Level Co-occurrence Matrix (CFLCM). We tested this method for several nucleus features. CFLCM is showed as a useful quantitative method for pleomorphism and heterogeneity on histopathological image

  18. Quantitative autistic trait measurements index background genetic risk for ASD in Hispanic families.

    PubMed

    Page, Joshua; Constantino, John Nicholas; Zambrana, Katherine; Martin, Eden; Tunc, Ilker; Zhang, Yi; Abbacchi, Anna; Messinger, Daniel

    2016-01-01

    Recent studies have indicated that quantitative autistic traits (QATs) of parents reflect inherited liabilities that may index background genetic risk for clinical autism spectrum disorder (ASD) in their offspring. Moreover, preferential mating for QATs has been observed as a potential factor in concentrating autistic liabilities in some families across generations. Heretofore, intergenerational studies of QATs have focused almost exclusively on Caucasian populations-the present study explored these phenomena in a well-characterized Hispanic population. The present study examined QAT scores in siblings and parents of 83 Hispanic probands meeting research diagnostic criteria for ASD, and 64 non-ASD controls, using the Social Responsiveness Scale-2 (SRS-2). Ancestry of the probands was characterized by genotype, using information from 541,929 single nucleotide polymorphic markers. In families of Hispanic children with an ASD diagnosis, the pattern of quantitative trait correlations observed between ASD-affected children and their first-degree relatives (ICCs on the order of 0.20), between unaffected first-degree relatives in ASD-affected families (sibling/mother ICC = 0.36; sibling/father ICC = 0.53), and between spouses (mother/father ICC = 0.48) were in keeping with the influence of transmitted background genetic risk and strong preferential mating for variation in quantitative autistic trait burden. Results from analysis of ancestry-informative genetic markers among probands in this sample were consistent with that from other Hispanic populations. Quantitative autistic traits represent measurable indices of inherited liability to ASD in Hispanic families. The accumulation of autistic traits occurs within generations, between spouses, and across generations, among Hispanic families affected by ASD. The occurrence of preferential mating for QATs-the magnitude of which may vary across cultures-constitutes a mechanism by which background genetic liability

  19. Affinity for Quantitative Tools: Undergraduate Marketing Students Moving beyond Quantitative Anxiety

    ERIC Educational Resources Information Center

    Tarasi, Crina O.; Wilson, J. Holton; Puri, Cheenu; Divine, Richard L.

    2013-01-01

    Marketing students are known as less likely to have an affinity for the quantitative aspects of the marketing discipline. In this article, we study the reasons why this might be true and develop a parsimonious 20-item scale for measuring quantitative affinity in undergraduate marketing students. The scale was administered to a sample of business…

  20. Failure to Integrate Quantitative Measurement Methods of Ocular Inflammation Hampers Clinical Practice and Trials on New Therapies for Posterior Uveitis.

    PubMed

    Herbort, Carl P; Tugal-Tutkun, Ilknur; Neri, Piergiorgio; Pavésio, Carlos; Onal, Sumru; LeHoang, Phuc

    2017-05-01

    Uveitis is one of the fields in ophthalmology where a tremendous evolution took place in the past 25 years. Not only did we gain access to more efficient, more targeted, and better tolerated therapies, but also in parallel precise and quantitative measurement methods developed allowing the clinician to evaluate these therapies and adjust therapeutic intervention with a high degree of precision. Objective and quantitative measurement of the global level of intraocular inflammation became possible for most inflammatory diseases with direct or spill-over anterior chamber inflammation, thanks to laser flare photometry. The amount of retinal inflammation could be quantified by using fluorescein angiography to score retinal angiographic signs. Indocyanine green angiography gave imaging insight into the hitherto inaccessible choroidal compartment, rendering possible the quantification of choroiditis by scoring indocyanine green angiographic signs. Optical coherence tomography has enabled measurement and objective monitoring of retinal and choroidal thickness. This multimodal quantitative appraisal of intraocular inflammation represents an exquisite security in monitoring uveitis. What is enigmatic, however, is the slow pace with which these improvements are integrated in some areas. What is even more difficult to understand is the fact that clinical trials to assess new therapeutic agents still mostly rely on subjective parameters such as clinical evaluation of vitreous haze as a main endpoint; whereas a whole array of precise, quantitative, and objective modalities are available for the design of clinical studies. The scope of this work was to review the quantitative investigations that improved the management of uveitis in the past 2-3 decades.

  1. Quantitative research.

    PubMed

    Watson, Roger

    2015-04-01

    This article describes the basic tenets of quantitative research. The concepts of dependent and independent variables are addressed and the concept of measurement and its associated issues, such as error, reliability and validity, are explored. Experiments and surveys – the principal research designs in quantitative research – are described and key features explained. The importance of the double-blind randomised controlled trial is emphasised, alongside the importance of longitudinal surveys, as opposed to cross-sectional surveys. Essential features of data storage are covered, with an emphasis on safe, anonymous storage. Finally, the article explores the analysis of quantitative data, considering what may be analysed and the main uses of statistics in analysis.

  2. Quantitative Ultrasound for Measuring Obstructive Severity in Children with Hydronephrosis.

    PubMed

    Cerrolaza, Juan J; Peters, Craig A; Martin, Aaron D; Myers, Emmarie; Safdar, Nabile; Linguraru, Marius George

    2016-04-01

    We define sonographic biomarkers for hydronephrotic renal units that can predict the necessity of diuretic nuclear renography. We selected a cohort of 50 consecutive patients with hydronephrosis of varying severity in whom 2-dimensional sonography and diuretic mercaptoacetyltriglycine renography had been performed. A total of 131 morphological parameters were computed using quantitative image analysis algorithms. Machine learning techniques were then applied to identify ultrasound based safety thresholds that agreed with the t½ for washout. A best fit model was then derived for each threshold level of t½ that would be clinically relevant at 20, 30 and 40 minutes. Receiver operating characteristic curve analysis was performed. Sensitivity, specificity and area under the receiver operating characteristic curve were determined. Improvement obtained by the quantitative imaging method compared to the Society for Fetal Urology grading system and the hydronephrosis index was statistically verified. For the 3 thresholds considered and at 100% sensitivity the specificities of the quantitative imaging method were 94%, 70% and 74%, respectively. Corresponding area under the receiver operating characteristic curve values were 0.98, 0.94 and 0.94, respectively. Improvement obtained by the quantitative imaging method over the Society for Fetal Urology grade and hydronephrosis index was statistically significant (p <0.05 in all cases). Quantitative imaging analysis of renal sonograms in children with hydronephrosis can identify thresholds of clinically significant washout times with 100% sensitivity to decrease the number of diuretic renograms in up to 62% of children. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  3. Autoradiographic localization of /sup 3/H-paroxetine-labeled serotonin uptake sites in rat brain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    De Souza, E.B.; Kuyatt, B.L.

    1987-01-01

    Paroxetine is a potent and selective inhibitor of serotonin uptake into neurons. Serotonin uptake sites have been identified, localized, and quantified in rat brain by autoradiography with 3H-paroxetine; 3H-paroxetine binding in slide-mounted sections of rat forebrain was of high affinity (KD = 10 pM) and the inhibition affinity constant (Ki) values of various drugs in competing 3H-paroxetine binding significantly correlated with their reported potencies in inhibiting synaptosomal serotonin uptake. Serotonin uptake sites labeled by 3H-paroxetine were highly concentrated in the dorsal and median raphe nuclei, central gray, superficial layer of the superior colliculus, lateral septal nucleus, paraventricular nucleus of themore » thalamus, and the islands of Calleja. High concentrations of 3H-paroxetine binding sites were found in brainstem areas containing dopamine (substantia nigra and ventral tegmental area) and norepinephrine (locus coeruleus) cell bodies. Moderate concentrations of 3H-paroxetine binding sites were present in laminae I and IV of the frontal parietal cortex, primary olfactory cortex, olfactory tubercle, regions of the basal ganglia, septum, amygdala, thalamus, hypothalamus, hippocampus, and some brainstem areas including the interpeduncular, trigeminal, and parabrachial nuclei. Lower densities of 3H-paroxetine binding sites were found in other regions of the neocortex and very low to nonsignificant levels of binding were present in white matter tracts and in the cerebellum. Lesioning of serotonin neurons with 3,4-methylenedioxyamphetamine caused large decreases in 3H-paroxetine binding. The autoradiographic distribution of 3H-paroxetine binding sites in rat brain corresponds extremely well to the distribution of serotonin terminals and cell bodies as well as with the pharmacological sites of action of serotonin.« less

  4. An autoradiographic analysis of the cortical connections of the pallidal and cerebellar zones within the feline motor thalamus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wensel, J.P.

    1989-01-01

    The feline motor thalamus relays both basal ganglia and cerebellar inputs to the motor cortex. This complex is classically subdivided into three nuclei: the ventroanterior nucleus (VA), the ventrolateral nucleus (VL), and the ventromedial nucleus (VM). Poor correlation between recognized patterns of cortical and subcortical connectivity and traditional boundaries used to distinguish these nuclei complicate the elucidation of the role they play in the elaboration of motor behavior. The recent demonstration of complementarity for the pallidothalamic and dentatothalamic projections to the motor thalamus of the cat provided the foundation for a revision of these nuclear borders to reflect differences inmore » subcortical connectivity. Using a revised topography, this study analyzed the afferent and efferent connections of the feline VA and VL through the application of both anterograde and retrograde tracing techniques. The extent of the cerebellothalamic projection, as revealed by the bidirectional transport of WGA-HRP, was used to demarcate the boundary between VA and VL. Injections of tritiated amino acids into VA and VL allowed for the autoradiographic tracing of their cortical projections. Autoradiography was also used to demonstrate the distributions of corticothalamic projections from selected pericruciate and posterior parietal subfields to the motor thalamus.« less

  5. Basic quantitative polymerase chain reaction using real-time fluorescence measurements.

    PubMed

    Ares, Manuel

    2014-10-01

    This protocol uses quantitative polymerase chain reaction (qPCR) to measure the number of DNA molecules containing a specific contiguous sequence in a sample of interest (e.g., genomic DNA or cDNA generated by reverse transcription). The sample is subjected to fluorescence-based PCR amplification and, theoretically, during each cycle, two new duplex DNA molecules are produced for each duplex DNA molecule present in the sample. The progress of the reaction during PCR is evaluated by measuring the fluorescence of dsDNA-dye complexes in real time. In the early cycles, DNA duplication is not detected because inadequate amounts of DNA are made. At a certain threshold cycle, DNA-dye complexes double each cycle for 8-10 cycles, until the DNA concentration becomes so high and the primer concentration so low that the reassociation of the product strands blocks efficient synthesis of new DNA and the reaction plateaus. There are two types of measurements: (1) the relative change of the target sequence compared to a reference sequence and (2) the determination of molecule number in the starting sample. The first requires a reference sequence, and the second requires a sample of the target sequence with known numbers of the molecules of sequence to generate a standard curve. By identifying the threshold cycle at which a sample first begins to accumulate DNA-dye complexes exponentially, an estimation of the numbers of starting molecules in the sample can be extrapolated. © 2014 Cold Spring Harbor Laboratory Press.

  6. Quantitative Laughter Detection, Measurement, and Classification-A Critical Survey.

    PubMed

    Cosentino, Sarah; Sessa, Salvatore; Takanishi, Atsuo

    2016-01-01

    The study of human nonverbal social behaviors has taken a more quantitative and computational approach in recent years due to the development of smart interfaces and virtual agents or robots able to interact socially. One of the most interesting nonverbal social behaviors, producing a characteristic vocal signal, is laughing. Laughter is produced in several different situations: in response to external physical, cognitive, or emotional stimuli; to negotiate social interactions; and also, pathologically, as a consequence of neural damage. For this reason, laughter has attracted researchers from many disciplines. A consequence of this multidisciplinarity is the absence of a holistic vision of this complex behavior: the methods of analysis and classification of laughter, as well as the terminology used, are heterogeneous; the findings sometimes contradictory and poorly documented. This survey aims at collecting and presenting objective measurement methods and results from a variety of different studies in different fields, to contribute to build a unified model and taxonomy of laughter. This could be successfully used for advances in several fields, from artificial intelligence and human-robot interaction to medicine and psychiatry.

  7. A literature review of quantitative indicators to measure the quality of labor and delivery care.

    PubMed

    Tripathi, Vandana

    2016-02-01

    Strengthening measurement of the quality of labor and delivery (L&D) care in low-resource countries requires an understanding of existing approaches. To identify quantitative indicators of L&D care quality and assess gaps in indicators. PubMed, CINAHL Plus, and Embase databases were searched for research published in English between January 1, 1990, and October 31, 2013, using structured terms. Studies describing indicators for L&D care quality assessment were included. Those whose abstracts contained inclusion criteria underwent full-text review. Study characteristics, including indicator selection and data sources, were extracted via a standard spreadsheet. The structured search identified 1224 studies. After abstract and full-text review, 477 were included in the analysis. Most studies selected indicators by using literature review, clinical guidelines, or expert panels. Few indicators were empirically validated; most studies relied on medical record review to measure indicators. Many quantitative indicators have been used to measure L&D care quality, but few have been validated beyond expert opinion. There has been limited use of clinical observation in quality assessment of care processes. The findings suggest the need for validated, efficient consensus indicators of the quality of L&D care processes, particularly in low-resource countries. Copyright © 2015 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  8. Initial description of a quantitative, cross-species (chimpanzee-human) social responsiveness measure.

    PubMed

    Marrus, Natasha; Faughn, Carley; Shuman, Jeremy; Petersen, Steve E; Constantino, John N; Povinelli, Daniel J; Pruett, John R

    2011-05-01

    Comparative studies of social responsiveness, an ability that is impaired in autism spectrum disorders, can inform our understanding of both autism and the cognitive architecture of social behavior. Because there is no existing quantitative measure of social responsiveness in chimpanzees, we generated a quantitative, cross-species (human-chimpanzee) social responsiveness measure. We translated the Social Responsiveness Scale (SRS), an instrument that quantifies human social responsiveness, into an analogous instrument for chimpanzees. We then retranslated this "Chimpanzee SRS" into a human "Cross-Species SRS" (XSRS). We evaluated three groups of chimpanzees (n = 29) with the Chimpanzee SRS and typical and human children with autism spectrum disorder (ASD; n = 20) with the XSRS. The Chimpanzee SRS demonstrated strong interrater reliability at the three sites (ranges for individual ICCs: 0.534 to 0.866; mean ICCs: 0.851 to 0.970). As has been observed in human beings, exploratory principal components analysis of Chimpanzee SRS scores supports a single factor underlying chimpanzee social responsiveness. Human subjects' XSRS scores were fully concordant with their SRS scores (r = 0.976, p = .001) and distinguished appropriately between typical and ASD subjects. One chimpanzee known for inappropriate social behavior displayed a significantly higher score than all other chimpanzees at its site, demonstrating the scale's ability to detect impaired social responsiveness in chimpanzees. Our initial cross-species social responsiveness scale proved reliable and discriminated differences in social responsiveness across (in a relative sense) and within (in a more objectively quantifiable manner) human beings and chimpanzees. Copyright © 2011 American Academy of Child and Adolescent Psychiatry. Published by Elsevier Inc. All rights reserved.

  9. Autoradiographic disposition of (1-methyl-/sup 14/C)- and (2-/sup 14/C)caffeine in mice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lachance, M.P.; Marlowe, C.; Waddell, W.J.

    1983-11-01

    Male, C57B1/6J mice received either (1-methyl-14C)caffeine or (2-14C)caffeine via the tail vein at a dose of 0.7 or 11 mg/kg, respectively. At 0.1, 0.33, 1, 3, 9, and 24 hr after treatment, the mice were anesthetized with ether and frozen by immersion in dry ice/hexane. The mice were processed for whole-body autoradiography by the Ullberg technique; this procedure does not allow thawing or contact with solvents. All autoradiographs revealed some retention of radioactivity at early time intervals in the lacrimal glands, seminal vesicle fluid, nasal and olfactory epithelium, and retinal melanocytes. The remaining portion of the animal was densitometrically uniformmore » except for the lower levels noted in the CNS and adipose tissues. Excretion of radioactivity by the liver and kidneys seems to be the major routes of elimination. Localization in the liver at late time intervals was confined principally to the centrilobular region. Late sites of retention, observed only after (1-methyl-14C)caffeine administration, included the pancreas, minor and major salivary glands, splenic red pulp, thymal cortex, bone marrow, and gastrointestinal epithelium. Sites of localization present in both studies included the olfactory epithelium, lacrimal glands, hair follicles, and retinal melanocytes. Further studies are needed to determine whether the localization at these various sites is due to metabolic degradation, active transport, or possibly a specific receptor interaction.« less

  10. Quantitative approach for optimizing e-beam condition of photoresist inspection and measurement

    NASA Astrophysics Data System (ADS)

    Lin, Chia-Jen; Teng, Chia-Hao; Cheng, Po-Chung; Sato, Yoshishige; Huang, Shang-Chieh; Chen, Chu-En; Maruyama, Kotaro; Yamazaki, Yuichiro

    2018-03-01

    Severe process margin in advanced technology node of semiconductor device is controlled by e-beam metrology system and e-beam inspection system with scanning electron microscopy (SEM) image. By using SEM, larger area image with higher image quality is required to collect massive amount of data for metrology and to detect defect in a large area for inspection. Although photoresist is the one of the critical process in semiconductor device manufacturing, observing photoresist pattern by SEM image is crucial and troublesome especially in the case of large image. The charging effect by e-beam irradiation on photoresist pattern causes deterioration of image quality, and it affect CD variation on metrology system and causes difficulties to continue defect inspection in a long time for a large area. In this study, we established a quantitative approach for optimizing e-beam condition with "Die to Database" algorithm of NGR3500 on photoresist pattern to minimize charging effect. And we enhanced the performance of measurement and inspection on photoresist pattern by using optimized e-beam condition. NGR3500 is the geometry verification system based on "Die to Database" algorithm which compares SEM image with design data [1]. By comparing SEM image and design data, key performance indicator (KPI) of SEM image such as "Sharpness", "S/N", "Gray level variation in FOV", "Image shift" can be retrieved. These KPIs were analyzed with different e-beam conditions which consist of "Landing Energy", "Probe Current", "Scanning Speed" and "Scanning Method", and the best e-beam condition could be achieved with maximum image quality, maximum scanning speed and minimum image shift. On this quantitative approach of optimizing e-beam condition, we could observe dependency of SEM condition on photoresist charging. By using optimized e-beam condition, measurement could be continued on photoresist pattern over 24 hours stably. KPIs of SEM image proved image quality during measurement and

  11. MR-ARFI-based method for the quantitative measurement of tissue elasticity: application for monitoring HIFU therapy

    NASA Astrophysics Data System (ADS)

    Vappou, Jonathan; Bour, Pierre; Marquet, Fabrice; Ozenne, Valery; Quesson, Bruno

    2018-05-01

    Monitoring thermal therapies through medical imaging is essential in order to ensure that they are safe, efficient and reliable. In this paper, we propose a new approach, halfway between MR acoustic radiation force imaging (MR-ARFI) and MR elastography (MRE), allowing for the quantitative measurement of the elastic modulus of tissue in a highly localized manner. It relies on the simulation of the MR-ARFI profile, which depends on tissue biomechanical properties, and on the identification of tissue elasticity through the fitting of experimental displacement images measured using rapid MR-ARFI. This method was specifically developed to monitor MR-guided high intensity focused ultrasound (MRgHIFU) therapy. Elasticity changes were followed during HIFU ablations (N  =  6) performed ex vivo in porcine muscle samples, and were compared to temperature changes measured by MR-thermometry. Shear modulus was found to increase consistently and steadily a few seconds after the heating started, and such changes were found to be irreversible. The shear modulus was found to increase from 1.49  ±  0.48 kPa (before ablation) to 3.69  ±  0.93 kPa (after ablation and cooling). Thanks to its ability to perform quantitative elasticity measurements in a highly localized manner around the focal spot, this method proved to be particularly attractive for monitoring HIFU ablations.

  12. Quantitative performance measurements of bent crystal Laue analyzers for X-ray fluorescence spectroscopy.

    PubMed

    Karanfil, C; Bunker, G; Newville, M; Segre, C U; Chapman, D

    2012-05-01

    Third-generation synchrotron radiation sources pose difficult challenges for energy-dispersive detectors for XAFS because of their count rate limitations. One solution to this problem is the bent crystal Laue analyzer (BCLA), which removes most of the undesired scatter and fluorescence before it reaches the detector, effectively eliminating detector saturation due to background. In this paper experimental measurements of BCLA performance in conjunction with a 13-element germanium detector, and a quantitative analysis of the signal-to-noise improvement of BCLAs are presented. The performance of BCLAs are compared with filters and slits.

  13. Navigational Traffic Conflict Technique: A Proactive Approach to Quantitative Measurement of Collision Risks in Port Waters

    NASA Astrophysics Data System (ADS)

    Debnath, Ashim Kumar; Chin, Hoong Chor

    Navigational safety analysis relying on collision statistics is often hampered because of the low number of observations. A promising alternative approach that overcomes this problem is proposed in this paper. By analyzing critical vessel interactions this approach proactively measures collision risk in port waters. The proposed method is illustrated for quantitative measurement of collision risks in Singapore port fairways, and validated by examining correlations between the measured risks with those perceived by pilots. This method is an ethically appealing alternative to the collision-based analysis for fast, reliable and effective safety assessment, thus possessing great potential for managing collision risks in port waters.

  14. Laser flare photometry: a noninvasive, objective, and quantitative method to measure intraocular inflammation.

    PubMed

    Tugal-Tutkun, Ilknur; Herbort, Carl P

    2010-10-01

    Aqueous flare and cells are the two inflammatory parameters of anterior chamber inflammation resulting from disruption of the blood-ocular barriers. When examined with the slit lamp, measurement of intraocular inflammation remains subjective with considerable intra- and interobserver variations. Laser flare cell photometry is an objective quantitative method that enables accurate measurement of these parameters with very high reproducibility. Laser flare photometry allows detection of subclinical alterations in the blood-ocular barriers, identifying subtle pathological changes that could not have been recorded otherwise. With the use of this method, it has been possible to compare the effect of different surgical techniques, surgical adjuncts, and anti-inflammatory medications on intraocular inflammation. Clinical studies of uveitis patients have shown that flare measurements by laser flare photometry allowed precise monitoring of well-defined uveitic entities and prediction of disease relapse. Relationships of laser flare photometry values with complications of uveitis and visual loss further indicate that flare measurement by laser flare photometry should be included in the routine follow-up of patients with uveitis.

  15. Quantitative measurement of stream respiration using the resazurin-resorufin system

    NASA Astrophysics Data System (ADS)

    Gonzalez Pinzon, R. A.; Acker, S.; Haggerty, R.; Myrold, D.

    2011-12-01

    After three decades of active research in hydrology and stream ecology, the relationship between stream solute transport, metabolism and nutrient dynamics is still unresolved. These knowledge gaps obscure the function of stream ecosystems and how they interact with other landscape processes. To date, measuring rates of stream metabolism is accomplished with techniques that have vast uncertainties and are not spatially representative. These limitations mask the role of metabolism in nutrient processing. Clearly, more robust techniques are needed to develop mechanistic relationships that will ultimately improve our fundamental understanding of in-stream processes and how streams interact with other ecosystems. We investigated the "metabolic window of detection" of the Resazurin (Raz)-Resorufin (Rru) system (Haggerty et al., 2008, 2009). Although previous results have shown that the transformation of Raz to Rru is strongly correlated with respiration, a quantitative relationship between them is needed. We investigated this relationship using batch experiments with pure cultures (aerobic and anaerobic) and flow-through columns with incubated sediments from four different streams. The results suggest that the Raz-Rru system is a suitable approach that will enable hydrologists and stream ecologists to measure in situ and in vivo respiration at different scales, thus opening a reliable alternative to investigate how solute transport and stream metabolism control nutrient processing.

  16. Sooting turbulent jet flame: characterization and quantitative soot measurements

    NASA Astrophysics Data System (ADS)

    Köhler, M.; Geigle, K. P.; Meier, W.; Crosland, B. M.; Thomson, K. A.; Smallwood, G. J.

    2011-08-01

    Computational fluid dynamics (CFD) modelers require high-quality experimental data sets for validation of their numerical tools. Preferred features for numerical simulations of a sooting, turbulent test case flame are simplicity (no pilot flame), well-defined boundary conditions, and sufficient soot production. This paper proposes a non-premixed C2H4/air turbulent jet flame to fill this role and presents an extensive database for soot model validation. The sooting turbulent jet flame has a total visible flame length of approximately 400 mm and a fuel-jet Reynolds number of 10,000. The flame has a measured lift-off height of 26 mm which acts as a sensitive marker for CFD model validation, while this novel compiled experimental database of soot properties, temperature and velocity maps are useful for the validation of kinetic soot models and numerical flame simulations. Due to the relatively simple burner design which produces a flame with sufficient soot concentration while meeting modelers' needs with respect to boundary conditions and flame specifications as well as the present lack of a sooting "standard flame", this flame is suggested as a new reference turbulent sooting flame. The flame characterization presented here involved a variety of optical diagnostics including quantitative 2D laser-induced incandescence (2D-LII), shifted-vibrational coherent anti-Stokes Raman spectroscopy (SV-CARS), and particle image velocimetry (PIV). Producing an accurate and comprehensive characterization of a transient sooting flame was challenging and required optimization of these diagnostics. In this respect, we present the first simultaneous, instantaneous PIV, and LII measurements in a heavily sooting flame environment. Simultaneous soot and flow field measurements can provide new insights into the interaction between a turbulent vortex and flame chemistry, especially since soot structures in turbulent flames are known to be small and often treated in a statistical manner.

  17. Boron concentration measurements by alpha spectrometry and quantitative neutron autoradiography in cells and tissues treated with different boronated formulations and administration protocols.

    PubMed

    Bortolussi, Silva; Ciani, Laura; Postuma, Ian; Protti, Nicoletta; Luca Reversi; Bruschi, Piero; Ferrari, Cinzia; Cansolino, Laura; Panza, Luigi; Ristori, Sandra; Altieri, Saverio

    2014-06-01

    The possibility to measure boron concentration with high precision in tissues that will be irradiated represents a fundamental step for a safe and effective BNCT treatment. In Pavia, two techniques have been used for this purpose, a quantitative method based on charged particles spectrometry and a boron biodistribution imaging based on neutron autoradiography. A quantitative method to determine boron concentration by neutron autoradiography has been recently set-up and calibrated for the measurement of biological samples, both solid and liquid, in the frame of the feasibility study of BNCT. This technique was calibrated and the obtained results were cross checked with those of α spectrometry, in order to validate them. The comparisons were performed using tissues taken form animals treated with different boron administration protocols. Subsequently the quantitative neutron autoradiography was employed to measure osteosarcoma cell samples treated with BPA and with new boronated formulations. © 2013 Published by Elsevier Ltd.

  18. Quantitative Measures for Evaluation of Ultrasound Therapies of the Prostate

    NASA Astrophysics Data System (ADS)

    Kobelevskiy, Ilya; Burtnyk, Mathieu; Bronskill, Michael; Chopra, Rajiv

    2010-03-01

    Development of non-invasive techniques for prostate cancer treatment requires implementation of quantitative measures for evaluation of the treatment results. In this paper. we introduce measures that estimate spatial targeting accuracy and potential thermal damage to the structures surrounding the prostate. The measures were developed for the technique of treating prostate cancer with a transurethral ultrasound heating applicators guided by active MR temperature feedback. Variations of ultrasound element length and related MR imaging parameters such as MR slice thickness and update time were investigated by performing numerical simulations of the treatment on a database of ten patient prostate geometries segmented from clinical MR images. Susceptibility of each parameter configuration to uncertainty in MR temperature measurements was studied by adding noise to the temperature measurements. Gaussian noise with zero mean and standard deviation of 0, 1, 3 and 5° C was used to model different levels of uncertainty in MR temperature measurements. Results of simulations for each parameter configuration were averaged over the database of the ten prostate patient geometries studied. Results have shown that for update time of 5 seconds both 3- and 5-mm elements achieve appropriate performance for temperature uncertainty up to 3° C, while temperature uncertainty of 5° C leads to noticeable reduction in spatial accuracy and increased risk of damaging rectal wall. Ten-mm elements lacked spatial accuracy and had higher risk of damaging rectal wall compared to 3- and 5-mm elements, but were less sensitive to the level of temperature uncertainty. The effect of changing update time was studied for 5-mm elements. Simulations showed that update time had minor effects on all aspects of treatment for temperature uncertainty of 0° C and 1° C, while temperature uncertainties of 3° C and 5° C led to reduced spatial accuracy, increased potential damage to the rectal wall, and

  19. Association between quantitative measures obtained using fluorescence-based methods and activity status of occlusal caries lesions in primary molars.

    PubMed

    Novaes, Tatiane Fernandes; Reyes, Alessandra; Matos, Ronilza; Antunes-Pontes, Laura Regina; Marques, Renata Pereira de Samuel; Braga, Mariana Minatel; Diniz, Michele Baffi; Mendes, Fausto Medeiros

    2017-05-01

    Fluorescence-based methods (FBM) can add objectiveness to diagnosis strategy for caries. Few studies, however, have focused on the evaluation of caries activity. To evaluate the association between quantitative measures obtained with FBM, clinical parameters acquired from the patients, caries detection, and assessment of activity status in occlusal surfaces of primary molars. Six hundred and six teeth from 113 children (4-14 years) were evaluated. The presence of a biofilm, caries experience, and the number of active lesions were recorded. The teeth were assessed using FBM: DIAGNOdent pen (Lfpen) and Quantitative light-induced fluorescence (QLF). As reference standard, all teeth were evaluated using the ICDAS (International Caries Detection and Assessment System) associated with clinical activity assessments. Multilevel regressions compared the FBM values and evaluated the association between the FBM measures and clinical variables related to the caries activity. The measures from the FBM were higher in cavitated lesions. Only, ∆F values distinguished active and inactive lesions. The LFpen measures were higher in active lesions, at the cavitated threshold (56.95 ± 29.60). Following regression analyses, only the presence of visible biofilm on occlusal surfaces (adjusted prevalence ratio = 1.43) and ∆R values of the teeth (adjusted prevalence ratio = 1.02) were associated with caries activity. Some quantitative measures from FBM parameters are associated with caries activity evaluation, which is similar to the clinical evaluation of the presence of visible biofilm. © 2016 BSPD, IAPD and John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Beyond Math Skills: Measuring Quantitative Reasoning in Context

    ERIC Educational Resources Information Center

    Grawe, Nathan D.

    2011-01-01

    It might be argued that quantitative and qualitative analyses are merely two alternative reflections of an overarching critical thinking. For instance, just as instructors of numeracy warn their charges to consider the construction of variables, teachers of qualitative approaches caution students to define terms. Similarly, an advocate of…

  1. Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation: Qualitative Classification and Quantitative Measurement.

    PubMed

    Tan, Xuhua; Lin, Haotian; Lin, Zhuoling; Chen, Jingjing; Tang, Xiangchen; Luo, Lixia; Chen, Weirong; Liu, Yizhi

    2016-03-01

    The objective of this study was to investigate capsular outcomes 12 months after pediatric cataract surgery without intraocular lens implantation via qualitative classification and quantitative measurement.This study is a cross-sectional study that was approved by the institutional review board of Zhongshan Ophthalmic Center of Sun Yat-sen University in Guangzhou, China.Digital coaxial retro-illumination photographs of 329 aphakic pediatric eyes were obtained 12 months after pediatric cataract surgery without intraocular lens implantation. Capsule digital coaxial retro-illumination photographs were divided as follows: anterior capsule opening area (ACOA), posterior capsule opening area (PCOA), and posterior capsule opening opacity (PCOO). Capsular outcomes were qualitatively classified into 3 types based on the PCOO: Type I-capsule with mild opacification but no invasion into the capsule opening; Type II-capsule with moderate opacification accompanied by contraction of the ACOA and invasion to the occluding part of the PCOA; and Type III-capsule with severe opacification accompanied by total occlusion of the PCOA. Software was developed to quantitatively measure the ACOA, PCOA, and PCOO using standardized DCRPs. The relationships between the accurate intraoperative anterior and posterior capsulorhexis sizes and the qualitative capsular types were statistically analyzed.The DCRPs of 315 aphakic eyes (95.8%) of 191 children were included. Capsular outcomes were classified into 3 types: Type I-120 eyes (38.1%); Type II-157 eyes (49.8%); Type III-38 eyes (12.1%). The scores of the capsular outcomes were negatively correlated with intraoperative anterior capsulorhexis size (R = -0.572, P < 0.001), but no significant correlation with intraoperative posterior capsulorhexis size (R = -0.16, P = 0.122) was observed. The ACOA significantly decreased from Type I to Type II to Type III, the PCOA increased in size from Type I to Type II, and the PCOO increased

  2. Quantitative computed tomography measurements of emphysema for diagnosing asthma-chronic obstructive pulmonary disease overlap syndrome

    PubMed Central

    Xie, Mengshuang; Wang, Wei; Dou, Shuang; Cui, Liwei; Xiao, Wei

    2016-01-01

    Background The diagnostic criteria of asthma–COPD overlap syndrome (ACOS) are controversial. Emphysema is characteristic of COPD and usually does not exist in typical asthma patients. Emphysema in patients with asthma suggests the coexistence of COPD. Quantitative computed tomography (CT) allows repeated evaluation of emphysema noninvasively. We investigated the value of quantitative CT measurements of emphysema in the diagnosis of ACOS. Methods This study included 404 participants; 151 asthma patients, 125 COPD patients, and 128 normal control subjects. All the participants underwent pulmonary function tests and a high-resolution CT scan. Emphysema measurements were taken with an Airway Inspector software. The asthma patients were divided into high and low emphysema index (EI) groups based on the percentage of low attenuation areas less than −950 Hounsfield units. The characteristics of asthma patients with high EI were compared with those having low EI or COPD. Results The normal value of percentage of low attenuation areas less than −950 Hounsfield units in Chinese aged >40 years was 2.79%±2.37%. COPD patients indicated more severe emphysema and more upper-zone-predominant distribution of emphysema than asthma patients or controls. Thirty-two (21.2%) of the 151 asthma patients had high EI. Compared with asthma patients with low EI, those with high EI were significantly older, more likely to be male, had more pack-years of smoking, had more upper-zone-predominant distribution of emphysema, and had greater airflow limitation. There were no significant differences in sex ratios, pack-years of smoking, airflow limitation, or emphysema distribution between asthma patients with high EI and COPD patients. A greater number of acute exacerbations were seen in asthma patients with high EI compared with those with low EI or COPD. Conclusion Asthma patients with high EI fulfill the features of ACOS, as described in the Global Initiative for Asthma and Global

  3. Imaging and quantitative measurement of corrosion in painted automotive and aircraft structures

    NASA Astrophysics Data System (ADS)

    Sun, G.; Wang, Xun; Feng, Z. J.; Jin, Huijia; Sui, Hua; Ouyang, Zhong; Han, Xiaoyan; Favro, L. D.; Thomas, R. L.; Bomback, J. L.

    2000-05-01

    Some of the authors have shown that it is possible to image and make rapid, quantitative measurements of metal thickness loss due to corrosion on the rear surface of a single layer structure, with an accuracy better than one percent. These measurements are complicated by the presence of thick and/or uneven layers of paint on either the front surface, the back surface, or both. We will discuss progress in overcoming these complications. Examples from both automotive and aircraft structures will be presented.—This material is based in part upon work performed at the FAA Center for Aviation Systems Reliability operated at Iowa State University and supported by the Federal Aviation Administration Technical Center, Atlantic City, New Jersey, under Grant number 95-G-025, and is also supported in part by the Institute for Manufacturing Research, Wayne State University, and by Ford Motor Company. Supported by a Grant from Ford Motor Company.

  4. The development of NEdSERV: quantitative instrumentation to measure service quality in nurse education.

    PubMed

    Roberts, P

    1999-07-01

    The political climate of health care provision and education for health care in the latter years of the 20th century is evolving from the uncertainty of newly created markets to a more clearly focused culture of collaboration, dissemination of good practice, with an increased emphasis on quality provision and its measurement. The need for provider units to prove and improve efficiency and effectiveness through evidence-based quality strategies in order to stay firmly in the market place has never been more necessary. The measurement of customer expectations and perceptions of delivered service quality is widely utilized as a basis for customer retention and business growth in both commercial and non-profit organizations. This paper describes the methodological development of NEdSERV--quantitative instrumentation designed to measure and respond to ongoing stakeholder expectations and perceptions of delivered service quality within nurse education.

  5. Quantitative measurements of in-cylinder gas composition in a controlled auto-ignition combustion engine

    NASA Astrophysics Data System (ADS)

    Zhao, H.; Zhang, S.

    2008-01-01

    One of the most effective means to achieve controlled auto-ignition (CAI) combustion in a gasoline engine is by the residual gas trapping method. The amount of residual gas and mixture composition have significant effects on the subsequent combustion process and engine emissions. In order to obtain quantitative measurements of in-cylinder residual gas concentration and air/fuel ratio, a spontaneous Raman scattering (SRS) system has been developed recently. The optimized optical SRS setups are presented and discussed. The temperature effect on the SRS measurement is considered and a method has been developed to correct for the overestimated values due to the temperature effect. Simultaneous measurements of O2, H2O, CO2 and fuel were obtained throughout the intake, compression, combustion and expansion strokes. It shows that the SRS can provide valuable data on this process in a CAI combustion engine.

  6. Proficiency testing as a basis for estimating uncertainty of measurement: application to forensic alcohol and toxicology quantitations.

    PubMed

    Wallace, Jack

    2010-05-01

    While forensic laboratories will soon be required to estimate uncertainties of measurement for those quantitations reported to the end users of the information, the procedures for estimating this have been little discussed in the forensic literature. This article illustrates how proficiency test results provide the basis for estimating uncertainties in three instances: (i) For breath alcohol analyzers the interlaboratory precision is taken as a direct measure of uncertainty. This approach applies when the number of proficiency tests is small. (ii) For blood alcohol, the uncertainty is calculated from the differences between the laboratory's proficiency testing results and the mean quantitations determined by the participants; this approach applies when the laboratory has participated in a large number of tests. (iii) For toxicology, either of these approaches is useful for estimating comparability between laboratories, but not for estimating absolute accuracy. It is seen that data from proficiency tests enable estimates of uncertainty that are empirical, simple, thorough, and applicable to a wide range of concentrations.

  7. Point-of-Care Quantitative Measure of Glucose-6-Phosphate Dehydrogenase Enzyme Deficiency.

    PubMed

    Bhutani, Vinod K; Kaplan, Michael; Glader, Bertil; Cotten, Michael; Kleinert, Jairus; Pamula, Vamsee

    2015-11-01

    Widespread newborn screening on a point-of-care basis could prevent bilirubin neurotoxicity in newborns with glucose-6-phosphate dehydrogenase (G6PD) deficiency. We evaluated a quantitative G6PD assay on a digital microfluidic platform by comparing its performance with standard clinical methods. G6PD activity was measured quantitatively by using digital microfluidic fluorescence and the gold standard fluorescence biochemical test on a convenience sample of 98 discarded blood samples. Twenty-four samples were designated as G6PD deficient. Mean ± SD G6PD activity for normal samples using the digital microfluidic method and the standard method, respectively, was 9.7 ± 2.8 and 11.1 ± 3.0 U/g hemoglobin (Hb), respectively; for G6PD-deficient samples, it was 0.8 ± 0.7 and 1.4 ± 0.9 U/g Hb. Bland-Altman analysis determined a mean difference of -0.96 ± 1.8 U/g Hb between the digital microfluidic fluorescence results and the standard biochemical test results. The lower and upper limits for the digital microfluidic platform were 4.5 to 19.5 U/g Hb for normal samples and 0.2 to 3.7 U/g Hb for G6PD-deficient samples. The lower and upper limits for the Stanford method were 5.5 to 20.7 U/g Hb for normal samples and 0.1 to 2.8 U/g Hb for G6PD-deficient samples. The measured activity discriminated between G6PD-deficient samples and normal samples with no overlap. Pending further validation, a digital microfluidics platform could be an accurate point-of-care screening tool for rapid newborn G6PD screening. Copyright © 2015 by the American Academy of Pediatrics.

  8. A rapid and quantitative assay for measuring antibody-mediated neutralization of West Nile virus infection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pierson, Theodore C.; Sanchez, Melissa D.; Puffer, Bridget A.

    2006-03-01

    West Nile virus (WNV) is a neurotropic flavivirus within the Japanese encephalitis antigenic complex that is responsible for causing West Nile encephalitis in humans. The surface of WNV virions is covered by a highly ordered icosahedral array of envelope proteins that is responsible for mediating attachment and fusion with target cells. These envelope proteins are also primary targets for the generation of neutralizing antibodies in vivo. In this study, we describe a novel approach for measuring antibody-mediated neutralization of WNV infection using virus-like particles that measure infection as a function of reporter gene expression. These reporter virus particles (RVPs) aremore » produced by complementation of a sub-genomic replicon with WNV structural proteins provided in trans using conventional DNA expression vectors. The precision and accuracy of this approach stem from an ability to measure the outcome of the interaction between antibody and viral antigens under conditions that satisfy the assumptions of the law of mass action as applied to virus neutralization. In addition to its quantitative strengths, this approach allows the production of WNV RVPs bearing the prM-E proteins of different WNV strains and mutants, offering considerable flexibility for the study of the humoral immune response to WNV in vitro. WNV RVPs are capable of only a single round of infection, can be used under BSL-2 conditions, and offer a rapid and quantitative approach for detecting virus entry and its inhibition by neutralizing antibody.« less

  9. Measuring the Unmeasurable: Upholding Rigor in Quantitative Studies of Personal and Social Development in Outdoor Adventure Education

    ERIC Educational Resources Information Center

    Scrutton, Roger; Beames, Simon

    2015-01-01

    Outdoor adventure education (OAE) has a long history of being credited with the personal and social development (PSD) of its participants. PSD is notoriously difficult to measure quantitatively, yet stakeholders demand statistical evidence that given approaches to eliciting PSD are effective in their methods. Rightly or wrongly, many stakeholders…

  10. Quantitative reactive modeling and verification.

    PubMed

    Henzinger, Thomas A

    Formal verification aims to improve the quality of software by detecting errors before they do harm. At the basis of formal verification is the logical notion of correctness , which purports to capture whether or not a program behaves as desired. We suggest that the boolean partition of software into correct and incorrect programs falls short of the practical need to assess the behavior of software in a more nuanced fashion against multiple criteria. We therefore propose to introduce quantitative fitness measures for programs, specifically for measuring the function, performance, and robustness of reactive programs such as concurrent processes. This article describes the goals of the ERC Advanced Investigator Project QUAREM. The project aims to build and evaluate a theory of quantitative fitness measures for reactive models. Such a theory must strive to obtain quantitative generalizations of the paradigms that have been success stories in qualitative reactive modeling, such as compositionality, property-preserving abstraction and abstraction refinement, model checking, and synthesis. The theory will be evaluated not only in the context of software and hardware engineering, but also in the context of systems biology. In particular, we will use the quantitative reactive models and fitness measures developed in this project for testing hypotheses about the mechanisms behind data from biological experiments.

  11. Semi-quantitative estimation of cellular SiO2 nanoparticles using flow cytometry combined with X-ray fluorescence measurements.

    PubMed

    Choi, Seo Yeon; Yang, Nuri; Jeon, Soo Kyung; Yoon, Tae Hyun

    2014-09-01

    In this study, we have demonstrated feasibility of a semi-quantitative approach for the estimation of cellular SiO2 nanoparticles (NPs), which is based on the flow cytometry measurements of their normalized side scattering intensity. In order to improve our understanding on the quantitative aspects of cell-nanoparticle interactions, flow cytometry, transmission electron microscopy, and X-ray fluorescence experiments were carefully performed for the HeLa cells exposed to SiO2 NPs with different core diameters, hydrodynamic sizes, and surface charges. Based on the observed relationships among the experimental data, a semi-quantitative cellular SiO2 NPs estimation method from their normalized side scattering and core diameters was proposed, which can be applied for the determination of cellular SiO2 NPs within their size-dependent linear ranges. © 2014 International Society for Advancement of Cytometry.

  12. Measuring the Internal Structure and Physical Conditions in Star and Planet Forming Clouds Cores: Towards a Quantitative Description of Cloud Evolution

    NASA Technical Reports Server (NTRS)

    Lada, Charles J.

    2004-01-01

    This grant funds a research program to use infrared extinction measurements to probe the detailed structure of dark molecular cloud cores and investigate the physical conditions which give rise to star and planet formation. The goals of this program are to acquire, reduce and analyze deep infrared and molecular-line observations of a carefully selected sample of nearby dark clouds in order to determine the detailed initial conditions for star formation from quantitative measurements of the internal structure of starless cloud cores and to quantitatively investigate the evolution of such structure through the star and planet formation process.

  13. Single-cell quantitative HER2 measurement identifies heterogeneity and distinct subgroups within traditionally defined HER2-positive patients.

    PubMed

    Onsum, Matthew D; Geretti, Elena; Paragas, Violette; Kudla, Arthur J; Moulis, Sharon P; Luus, Lia; Wickham, Thomas J; McDonagh, Charlotte F; MacBeath, Gavin; Hendriks, Bart S

    2013-11-01

    Human epidermal growth factor receptor 2 (HER2) is an important biomarker for breast and gastric cancer prognosis and patient treatment decisions. HER2 positivity, as defined by IHC or fluorescent in situ hybridization testing, remains an imprecise predictor of patient response to HER2-targeted therapies. Challenges to correct HER2 assessment and patient stratification include intratumoral heterogeneity, lack of quantitative and/or objective assays, and differences between measuring HER2 amplification at the protein versus gene level. We developed a novel immunofluorescence method for quantitation of HER2 protein expression at the single-cell level on FFPE patient samples. Our assay uses automated image analysis to identify and classify tumor versus non-tumor cells, as well as quantitate the HER2 staining for each tumor cell. The HER2 staining level is converted to HER2 protein expression using a standard cell pellet array stained in parallel with the tissue sample. This approach allows assessment of HER2 expression and heterogeneity within a tissue section at the single-cell level. By using this assay, we identified distinct subgroups of HER2 heterogeneity within traditional definitions of HER2 positivity in both breast and gastric cancers. Quantitative assessment of intratumoral HER2 heterogeneity may offer an opportunity to improve the identification of patients likely to respond to HER2-targeted therapies. The broad applicability of the assay was demonstrated by measuring HER2 expression profiles on multiple tumor types, and on normal and diseased heart tissues. Copyright © 2013 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  14. Phosphorescent nanoparticles for quantitative measurements of oxygen profiles in vitro and in vivo

    PubMed Central

    Choi, Nak Won; Verbridge, Scott S.; Williams, Rebecca M.; Chen, Jin; Kim, Ju-Young; Schmehl, Russel; Farnum, Cornelia E.; Zipfel, Warren R.; Fischbach, Claudia; Stroock, Abraham D.

    2012-01-01

    We present the development and characterization of nanoparticles loaded with a custom phosphor; we exploit these nanoparticles to perform quantitative measurements of the concentration of oxygen within three-dimensional (3-D) tissue cultures in vitro and blood vessels in vivo. We synthesized a customized ruthenium (Ru)-phosphor and incorporated it into polymeric nanoparticles via self-assembly. We demonstrate that the encapsulated phosphor is non-toxic with and without illumination. We evaluated two distinct modes of employing the phosphorescent nanoparticles for the measurement of concentrations of oxygen: 1) in vitro, in a 3-D microfluidic tumor model via ratiometric measurements of intensity with an oxygen-insensitive fluorophore as a reference, and 2) in vivo, in mouse vasculature using measurements of phosphorescence lifetime. With both methods, we demonstrated micrometer-scale resolution and absolute calibration to the dissolved oxygen concentration. Based on the ease and customizability of the synthesis of the nanoparticles and the flexibility of their application, these oxygen-sensing polymeric nanoparticles will find a natural home in a range of biological applications, benefiting studies of physiological as well as pathological processes in which oxygen availability and concentration play a critical role. PMID:22240511

  15. QUANTITATIVE MORPHOLOGY

    EPA Science Inventory

    Abstract: In toxicology, the role of quantitative assessment of brain morphology can be understood in the context of two types of treatment-related alterations. One type of alteration is specifically associated with treatment and is not observed in control animals. Measurement ...

  16. Quantitative measurements of magnetic vortices using position resolved diffraction in Lorentz STEM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zaluzec, N. J.

    2002-03-05

    A number of electron column techniques have been developed over the last forty years to permit visualization of magnetic fields in specimens. These include: Fresnel imaging, Differential Phase Contrast, Electron Holography and Lorentz STEM. In this work we have extended the LSTEM methodology using Position Resolved Diffraction (PRD) to quantitatively measure the in-plane electromagnetic fields of thin film materials. The experimental work reported herein has been carried out using the ANL AAEM HB603Z 300 kV FEG instrument 5. In this instrument, the electron optical column was operated in a zero field mode, at the specimen, where the objective lens ismore » turned off and the probe forming lens functions were reallocated to the C1, C2, and C3 lenses. Post specimen lenses (P1, P2, P3, P4) were used to magnify the transmitted electrons to a YAG screen, which was then optically transferred to a Hamamatsu ORCA ER CCD array. This CCD was interfaced to an EmiSpec Data Acquisition System and the data was subsequently transferred to an external computer system for detailed quantitative analysis. In Position Resolved Diffraction mode, we digitally step a focused electron probe across the region of interest of the specimen while at the same time recording the complete diffraction pattern at each point in the scan.« less

  17. Quantitative Glycomics Strategies*

    PubMed Central

    Mechref, Yehia; Hu, Yunli; Desantos-Garcia, Janie L.; Hussein, Ahmed; Tang, Haixu

    2013-01-01

    The correlations between protein glycosylation and many biological processes and diseases are increasing the demand for quantitative glycomics strategies enabling sensitive monitoring of changes in the abundance and structure of glycans. This is currently attained through multiple strategies employing several analytical techniques such as capillary electrophoresis, liquid chromatography, and mass spectrometry. The detection and quantification of glycans often involve labeling with ionic and/or hydrophobic reagents. This step is needed in order to enhance detection in spectroscopic and mass spectrometric measurements. Recently, labeling with stable isotopic reagents has also been presented as a very viable strategy enabling relative quantitation. The different strategies available for reliable and sensitive quantitative glycomics are herein described and discussed. PMID:23325767

  18. Reproducibility of Quantitative Structural and Physiological MRI Measurements

    DTIC Science & Technology

    2017-08-09

    per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and...Journal Article 3. DATES COVERED (From – To) January 2015 – July 2017 4. TITLE AND SUBTITLE Reproducibility of Quantitative Structural and...NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) USAF School of Aerospace Medicine Aeromedical Research Dept/FHOH 2510 Fifth St., Bldg

  19. Evolution of Quantitative Measures in NMR: Quantum Mechanical qHNMR Advances Chemical Standardization of a Red Clover (Trifolium pratense) Extract

    PubMed Central

    2017-01-01

    Chemical standardization, along with morphological and DNA analysis ensures the authenticity and advances the integrity evaluation of botanical preparations. Achievement of a more comprehensive, metabolomic standardization requires simultaneous quantitation of multiple marker compounds. Employing quantitative 1H NMR (qHNMR), this study determined the total isoflavone content (TIfCo; 34.5–36.5% w/w) via multimarker standardization and assessed the stability of a 10-year-old isoflavone-enriched red clover extract (RCE). Eleven markers (nine isoflavones, two flavonols) were targeted simultaneously, and outcomes were compared with LC-based standardization. Two advanced quantitative measures in qHNMR were applied to derive quantities from complex and/or overlapping resonances: a quantum mechanical (QM) method (QM-qHNMR) that employs 1H iterative full spin analysis, and a non-QM method that uses linear peak fitting algorithms (PF-qHNMR). A 10 min UHPLC-UV method provided auxiliary orthogonal quantitation. This is the first systematic evaluation of QM and non-QM deconvolution as qHNMR quantitation measures. It demonstrates that QM-qHNMR can account successfully for the complexity of 1H NMR spectra of individual analytes and how QM-qHNMR can be built for mixtures such as botanical extracts. The contents of the main bioactive markers were in good agreement with earlier HPLC-UV results, demonstrating the chemical stability of the RCE. QM-qHNMR advances chemical standardization by its inherent QM accuracy and the use of universal calibrants, avoiding the impractical need for identical reference materials. PMID:28067513

  20. Characterization and autoradiographic localization of beta-adrenoceptor subtypes in human cardiac tissues.

    PubMed Central

    Buxton, B. F.; Jones, C. R.; Molenaar, P.; Summers, R. J.

    1987-01-01

    1 Receptor autoradiography using (-)-[125I]-cyanopindolol (CYP) was used to study the distribution of beta-adrenoceptor subtypes in human right atrial appendage, left atrial free wall, left ventricular papillary muscle and pericardium. 2 The binding of (-)-[125I]-CYP to slide-mounted tissue sections of human right atrial appendage was time-dependent (K1 = 4.11 +/- 1.01 X 10(8) M-1 min-1, K-1 = 1.47 +/- 0.25 X 10(-3) min-1, n = 3), saturable (42.02 +/- 2.96 pM, n = 4) and stereoselective with respect to the optical isomers of propranolol (pKD (-):8.97 +/- 0.02, (+):6.88 +/- 0.06, n = 3). 3 The proportions of beta-adrenoceptor subtypes were determined in slide-mounted tissue sections using the antagonists CGP 20712A (beta 1-selective) and ICI 118,551 (beta 2-selective). In right atrial appendage and left ventricular papillary muscle 40% (34-45%) of the beta-adrenoceptors were of the beta 2-subtype. 4 Images from X-ray film and nuclear emulsion coated coverslips exposed to (-)-[125I]-CYP-labelled sections showed an even distribution of beta-adrenoceptor subtypes over the myocardium of the right atrial appendage, left ventricular papillary muscle and left atrial free wall. Sections of pericardium exhibited predominantly beta 2-adrenoceptors. beta 2-Adrenoceptors were localized to the intimal surface of coronary arteries. 5 The selective beta 1-adrenoceptor agonist RO363 and beta 2-selective agonist procaterol produced concentration-dependent inotropic responses in right atrial appendage strips. Responses to RO363 were antagonized by CGP 20712A (pKB = 9.29) suggesting an interaction with beta 1-adrenoceptors. Responses to procaterol were antagonized by ICI 118,551 (pKB = 9.06) suggesting an interaction at beta 2-adrenoceptors. 6 The finding that a significant proportion of human myocardial adrenoceptors are of the beta 2-subtype has important clinical implications for the involvement of these receptors in the control of heart rate and force, and the autoradiographic

  1. Quantitative measurement of pass-by noise radiated by vehicles running at high speeds

    NASA Astrophysics Data System (ADS)

    Yang, Diange; Wang, Ziteng; Li, Bing; Luo, Yugong; Lian, Xiaomin

    2011-03-01

    It has been a challenge in the past to accurately locate and quantify the pass-by noise source radiated by the running vehicles. A system composed of a microphone array is developed in our current work to do this work. An acoustic-holography method for moving sound sources is designed to handle the Doppler effect effectively in the time domain. The effective sound pressure distribution is reconstructed on the surface of a running vehicle. The method has achieved a high calculation efficiency and is able to quantitatively measure the sound pressure at the sound source and identify the location of the main sound source. The method is also validated by the simulation experiments and the measurement tests with known moving speakers. Finally, the engine noise, tire noise, exhaust noise and wind noise of the vehicle running at different speeds are successfully identified by this method.

  2. Basal levels of metabolic activity are elevated in Genetic Absence Epilepsy Rats from Strasbourg (GAERS): measurement of regional activity of cytochrome oxidase and lactate dehydrogenase by histochemistry.

    PubMed

    Dufour, Franck; Koning, Estelle; Nehlig, Astrid

    2003-08-01

    The Genetic Absence Epilepsy Rats from Strasbourg (GAERS) are considered an isomorphic, predictive, and homologous model of human generalized absence epilepsy. It is characterized by the expression of spike-and-wave discharges in the thalamus and cortex. In this strain, basal regional rates of cerebral glucose utilization measured by the quantitative autoradiographic [(14)C]2-deoxyglucose technique display a widespread consistent increase compared to a selected strain of genetically nonepileptic rats (NE). In order to verify whether these high rates of glucose metabolism are paralleled by elevated activities of the enzymes of the glycolytic and tricarboxylic acid cycle pathways, we measured by histochemistry the regional activity of the two key enzymes of glucose metabolism, lactate dehydrogenase (LDH) for the anaerobic pathway and cytochrome oxidase (CO) for the aerobic pathway coupled to oxidative phosphorylation. CO and LDH activities were significantly higher in GAERS than in NE rats in 24 and 28 of the 30 brain regions studied, respectively. The differences in CO and LDH activity between both strains were widespread, affected all brain systems studied, and ranged from 12 to 63%. The data of the present study confirm the generalized increase in cerebral glucose metabolism in GAERS, occurring both at the glycolytic and at the oxidative step. However, they still do not allow us to understand why the ubiquitous mutation(s) generates spike-and-wave discharges only in the thalamocortical circuit.

  3. Unmixing of fluorescence spectra to resolve quantitative time-series measurements of gene expression in plate readers.

    PubMed

    Lichten, Catherine A; White, Rachel; Clark, Ivan B N; Swain, Peter S

    2014-02-03

    To connect gene expression with cellular physiology, we need to follow levels of proteins over time. Experiments typically use variants of Green Fluorescent Protein (GFP), and time-series measurements require specialist expertise if single cells are to be followed. Fluorescence plate readers, however, a standard in many laboratories, can in principle provide similar data, albeit at a mean, population level. Nevertheless, extracting the average fluorescence per cell is challenging because autofluorescence can be substantial. Here we propose a general method for correcting plate reader measurements of fluorescent proteins that uses spectral unmixing and determines both the fluorescence per cell and the errors on that fluorescence. Combined with strain collections, such as the GFP fusion collection for budding yeast, our methodology allows quantitative measurements of protein levels of up to hundreds of genes and therefore provides complementary data to high throughput studies of transcription. We illustrate the method by following the induction of the GAL genes in Saccharomyces cerevisiae for over 20 hours in different sugars and argue that the order of appearance of the Leloir enzymes may be to reduce build-up of the toxic intermediate galactose-1-phosphate. Further, we quantify protein levels of over 40 genes, again over 20 hours, after cells experience a change in carbon source (from glycerol to glucose). Our methodology is sensitive, scalable, and should be applicable to other organisms. By allowing quantitative measurements on a per cell basis over tens of hours and over hundreds of genes, it should increase our understanding of the dynamic changes that drive cellular behaviour.

  4. Unmixing of fluorescence spectra to resolve quantitative time-series measurements of gene expression in plate readers

    PubMed Central

    2014-01-01

    Background To connect gene expression with cellular physiology, we need to follow levels of proteins over time. Experiments typically use variants of Green Fluorescent Protein (GFP), and time-series measurements require specialist expertise if single cells are to be followed. Fluorescence plate readers, however, a standard in many laboratories, can in principle provide similar data, albeit at a mean, population level. Nevertheless, extracting the average fluorescence per cell is challenging because autofluorescence can be substantial. Results Here we propose a general method for correcting plate reader measurements of fluorescent proteins that uses spectral unmixing and determines both the fluorescence per cell and the errors on that fluorescence. Combined with strain collections, such as the GFP fusion collection for budding yeast, our methodology allows quantitative measurements of protein levels of up to hundreds of genes and therefore provides complementary data to high throughput studies of transcription. We illustrate the method by following the induction of the GAL genes in Saccharomyces cerevisiae for over 20 hours in different sugars and argue that the order of appearance of the Leloir enzymes may be to reduce build-up of the toxic intermediate galactose-1-phosphate. Further, we quantify protein levels of over 40 genes, again over 20 hours, after cells experience a change in carbon source (from glycerol to glucose). Conclusions Our methodology is sensitive, scalable, and should be applicable to other organisms. By allowing quantitative measurements on a per cell basis over tens of hours and over hundreds of genes, it should increase our understanding of the dynamic changes that drive cellular behaviour. PMID:24495318

  5. Quantitative measurement of mitochondrial membrane potential in cultured cells: calcium-induced de- and hyperpolarization of neuronal mitochondria

    PubMed Central

    Gerencser, Akos A; Chinopoulos, Christos; Birket, Matthew J; Jastroch, Martin; Vitelli, Cathy; Nicholls, David G; Brand, Martin D

    2012-01-01

    Mitochondrial membrane potential (ΔΨM) is a central intermediate in oxidative energy metabolism. Although ΔΨM is routinely measured qualitatively or semi-quantitatively using fluorescent probes, its quantitative assay in intact cells has been limited mostly to slow, bulk-scale radioisotope distribution methods. Here we derive and verify a biophysical model of fluorescent potentiometric probe compartmentation and dynamics using a bis-oxonol-type indicator of plasma membrane potential (ΔΨP) and the ΔΨM probe tetramethylrhodamine methyl ester (TMRM) using fluorescence imaging and voltage clamp. Using this model we introduce a purely fluorescence-based quantitative assay to measure absolute values of ΔΨM in millivolts as they vary in time in individual cells in monolayer culture. The ΔΨP-dependent distribution of the probes is modelled by Eyring rate theory. Solutions of the model are used to deconvolute ΔΨP and ΔΨM in time from the probe fluorescence intensities, taking into account their slow, ΔΨP-dependent redistribution and Nernstian behaviour. The calibration accounts for matrix:cell volume ratio, high- and low-affinity binding, activity coefficients, background fluorescence and optical dilution, allowing comparisons of potentials in cells or cell types differing in these properties. In cultured rat cortical neurons, ΔΨM is −139 mV at rest, and is regulated between −108 mV and −158 mV by concerted increases in ATP demand and Ca2+-dependent metabolic activation. Sensitivity analysis showed that the standard error of the mean in the absolute calibrated values of resting ΔΨM including all biological and systematic measurement errors introduced by the calibration parameters is less than 11 mV. Between samples treated in different ways, the typical equivalent error is ∼5 mV. PMID:22495585

  6. Genome-Wide Association Studies of Quantitatively Measured Skin, Hair, and Eye Pigmentation in Four European Populations

    PubMed Central

    Candille, Sophie I.; Absher, Devin M.; Beleza, Sandra; Bauchet, Marc; McEvoy, Brian; Garrison, Nanibaa’ A.; Li, Jun Z.; Myers, Richard M.; Barsh, Gregory S.; Tang, Hua; Shriver, Mark D.

    2012-01-01

    Pigmentation of the skin, hair, and eyes varies both within and between human populations. Identifying the genes and alleles underlying this variation has been the goal of many candidate gene and several genome-wide association studies (GWAS). Most GWAS for pigmentary traits to date have been based on subjective phenotypes using categorical scales. But skin, hair, and eye pigmentation vary continuously. Here, we seek to characterize quantitative variation in these traits objectively and accurately and to determine their genetic basis. Objective and quantitative measures of skin, hair, and eye color were made using reflectance or digital spectroscopy in Europeans from Ireland, Poland, Italy, and Portugal. A GWAS was conducted for the three quantitative pigmentation phenotypes in 176 women across 313,763 SNP loci, and replication of the most significant associations was attempted in a sample of 294 European men and women from the same countries. We find that the pigmentation phenotypes are highly stratified along axes of European genetic differentiation. The country of sampling explains approximately 35% of the variation in skin pigmentation, 31% of the variation in hair pigmentation, and 40% of the variation in eye pigmentation. All three quantitative phenotypes are correlated with each other. In our two-stage association study, we reproduce the association of rs1667394 at the OCA2/HERC2 locus with eye color but we do not identify new genetic determinants of skin and hair pigmentation supporting the lack of major genes affecting skin and hair color variation within Europe and suggesting that not only careful phenotyping but also larger cohorts are required to understand the genetic architecture of these complex quantitative traits. Interestingly, we also see that in each of these four populations, men are more lightly pigmented in the unexposed skin of the inner arm than women, a fact that is underappreciated and may vary across the world. PMID:23118974

  7. Non-invasive tissue temperature measurements based on quantitative diffuse optical spectroscopy (DOS) of water.

    PubMed

    Chung, S H; Cerussi, A E; Merritt, S I; Ruth, J; Tromberg, B J

    2010-07-07

    We describe the development of a non-invasive method for quantitative tissue temperature measurements using Broadband diffuse optical spectroscopy (DOS). Our approach is based on well-characterized opposing shifts in near-infrared (NIR) water absorption spectra that appear with temperature and macromolecular binding state. Unlike conventional reflectance methods, DOS is used to generate scattering-corrected tissue water absorption spectra. This allows us to separate the macromolecular bound water contribution from the thermally induced spectral shift using the temperature isosbestic point at 996 nm. The method was validated in intralipid tissue phantoms by correlating DOS with thermistor measurements (R=0.96) with a difference of 1.1+/-0.91 degrees C over a range of 28-48 degrees C. Once validated, thermal and hemodynamic (i.e. oxy- and deoxy-hemoglobin concentration) changes were measured simultaneously and continuously in human subjects (forearm) during mild cold stress. DOS-measured arm temperatures were consistent with previously reported invasive deep tissue temperature studies. These results suggest that DOS can be used for non-invasive, co-registered measurements of absolute temperature and hemoglobin parameters in thick tissues, a potentially important approach for optimizing thermal diagnostics and therapeutics.

  8. Quantitative mass spectrometry: an overview

    NASA Astrophysics Data System (ADS)

    Urban, Pawel L.

    2016-10-01

    Mass spectrometry (MS) is a mainstream chemical analysis technique in the twenty-first century. It has contributed to numerous discoveries in chemistry, physics and biochemistry. Hundreds of research laboratories scattered all over the world use MS every day to investigate fundamental phenomena on the molecular level. MS is also widely used by industry-especially in drug discovery, quality control and food safety protocols. In some cases, mass spectrometers are indispensable and irreplaceable by any other metrological tools. The uniqueness of MS is due to the fact that it enables direct identification of molecules based on the mass-to-charge ratios as well as fragmentation patterns. Thus, for several decades now, MS has been used in qualitative chemical analysis. To address the pressing need for quantitative molecular measurements, a number of laboratories focused on technological and methodological improvements that could render MS a fully quantitative metrological platform. In this theme issue, the experts working for some of those laboratories share their knowledge and enthusiasm about quantitative MS. I hope this theme issue will benefit readers, and foster fundamental and applied research based on quantitative MS measurements. This article is part of the themed issue 'Quantitative mass spectrometry'.

  9. Quantitative Assessment of Parkinsonian Tremor Based on an Inertial Measurement Unit

    PubMed Central

    Dai, Houde; Zhang, Pengyue; Lueth, Tim C.

    2015-01-01

    Quantitative assessment of parkinsonian tremor based on inertial sensors can provide reliable feedback on the effect of medication. In this regard, the features of parkinsonian tremor and its unique properties such as motor fluctuations and dyskinesia are taken into account. Least-square-estimation models are used to assess the severities of rest, postural, and action tremors. In addition, a time-frequency signal analysis algorithm for tremor state detection was also included in the tremor assessment method. This inertial sensor-based method was verified through comparison with an electromagnetic motion tracking system. Seven Parkinson’s disease (PD) patients were tested using this tremor assessment system. The measured tremor amplitudes correlated well with the judgments of a neurologist (r = 0.98). The systematic analysis of sensor-based tremor quantification and the corresponding experiments could be of great help in monitoring the severity of parkinsonian tremor. PMID:26426020

  10. Overview of Classical Test Theory and Item Response Theory for Quantitative Assessment of Items in Developing Patient-Reported Outcome Measures

    PubMed Central

    Cappelleri, Joseph C.; Lundy, J. Jason; Hays, Ron D.

    2014-01-01

    Introduction The U.S. Food and Drug Administration’s patient-reported outcome (PRO) guidance document defines content validity as “the extent to which the instrument measures the concept of interest” (FDA, 2009, p. 12). “Construct validity is now generally viewed as a unifying form of validity for psychological measurements, subsuming both content and criterion validity” (Strauss & Smith, 2009, p. 7). Hence both qualitative and quantitative information are essential in evaluating the validity of measures. Methods We review classical test theory and item response theory approaches to evaluating PRO measures including frequency of responses to each category of the items in a multi-item scale, the distribution of scale scores, floor and ceiling effects, the relationship between item response options and the total score, and the extent to which hypothesized “difficulty” (severity) order of items is represented by observed responses. Conclusion Classical test theory and item response theory can be useful in providing a quantitative assessment of items and scales during the content validity phase of patient-reported outcome measures. Depending on the particular type of measure and the specific circumstances, either one or both approaches should be considered to help maximize the content validity of PRO measures. PMID:24811753

  11. Real-time quantitative fluorescence measurement of microscale cell culture analog systems

    NASA Astrophysics Data System (ADS)

    Oh, Taek-il; Kim, Donghyun; Tatosian, Daniel; Sung, Jong Hwan; Shuler, Michael

    2007-02-01

    A microscale cell culture analog (μCCA) is a cell-based lab-on-a-chip assay that, as an animal surrogate, is applied to pharmacological studies for toxicology tests. A μCCA typically comprises multiple chambers and microfluidics that connect the chambers, which represent animal organs and blood flow to mimic animal metabolism more realistically. A μCCA is expected to provide a tool for high-throughput drug discovery. Previously, a portable fluorescence detection system was investigated for a single μCCA device in real-time. In this study, we present a fluorescence-based imaging system that provides quantitative real-time data of the metabolic interactions in μCCAs with an emphasis on measuring multiple μCCA samples simultaneously for high-throughput screening. The detection system is based on discrete optics components, with a high-power LED and a charge-coupled device (CCD) camera as a light source and a detector, for monitoring cellular status on the chambers of each μCCA sample. Multiple samples are characterized mechanically on a motorized linear stage, which is fully-automated. Each μCCA sample has four chambers, where cell lines MES-SA/DX- 5, and MES-SA (tumor cells of human uterus) have been cultured. All cell-lines have been transfected to express the fusion protein H2B-GFP, which is a human histone protein fused at the amino terminus to EGFP. As a model cytotoxic drug, 10 μM doxorubicin (DOX) was used. Real-time quantitative data of the intensity loss of enhanced green fluorescent protein (EGFP) during cell death of target cells have been collected over several minutes to 40 hours. Design issues and improvements are also discussed.

  12. Validation of a quantitative magnetic resonance method for measuring human body composition.

    PubMed

    Napolitano, Antonella; Miller, Sam R; Murgatroyd, Peter R; Coward, W Andrew; Wright, Antony; Finer, Nick; De Bruin, Tjerk W; Bullmore, Edward T; Nunez, Derek J

    2008-01-01

    To evaluate a novel quantitative magnetic resonance (QMR) methodology (EchoMRI-AH, Echo Medical Systems) for measurement of whole-body fat and lean mass in humans. We have studied (i) the in vitro accuracy and precision by measuring 18 kg Canola oil with and without 9 kg water (ii) the accuracy and precision of measures of simulated fat mass changes in human subjects (n = 10) and (iii) QMR fat and lean mass measurements compared to those obtained using the established 4-compartment (4-C) model method (n = 30). (i) QMR represented 18 kg of oil at 40 degrees C as 17.1 kg fat and 1 kg lean while at 30 degrees C 15.8 kg fat and 4.7 kg lean were reported. The s.d. of repeated estimates was 0.13 kg for fat and 0.23 kg for lean mass. Adding 9 kg of water reduced the fat estimates, increased misrepresentation of fat as lean, and degraded the precision. (ii) the simulated change in the fat mass of human volunteers was accurately represented, independently of added water. (iii) compared to the 4-C model, QMR underestimated fat and over-estimated lean mass. The extent of difference increased with body mass. The s.d. of repeated measurements increased with adiposity, from 0.25 kg (fat) and 0.51 kg (lean) with BMI <25 kg/m(2) to 0.43 kg and 0.81 kg respectively with BMI >30 kg/m(2). EchoMRI-AH prototype showed shortcomings in absolute accuracy and specificity of fat mass measures, but detected simulated body composition change accurately and with precision roughly three times better than current best measures. This methodology should reduce the study duration and cohort number needed to evaluate anti-obesity interventions.

  13. Porous Silicon Antibody Microarrays for Quantitative Analysis: Measurement of Free and Total PSA in Clinical Plasma Samples

    PubMed Central

    Tojo, Axel; Malm, Johan; Marko-Varga, György; Lilja, Hans; Laurell, Thomas

    2014-01-01

    The antibody microarrays have become widespread, but their use for quantitative analyses in clinical samples has not yet been established. We investigated an immunoassay based on nanoporous silicon antibody microarrays for quantification of total prostate-specific-antigen (PSA) in 80 clinical plasma samples, and provide quantitative data from a duplex microarray assay that simultaneously quantifies free and total PSA in plasma. To further develop the assay the porous silicon chips was placed into a standard 96-well microtiter plate for higher throughput analysis. The samples analyzed by this quantitative microarray were 80 plasma samples obtained from men undergoing clinical PSA testing (dynamic range: 0.14-44ng/ml, LOD: 0.14ng/ml). The second dataset, measuring free PSA (dynamic range: 0.40-74.9ng/ml, LOD: 0.47ng/ml) and total PSA (dynamic range: 0.87-295ng/ml, LOD: 0.76ng/ml), was also obtained from the clinical routine. The reference for the quantification was a commercially available assay, the ProStatus PSA Free/Total DELFIA. In an analysis of 80 plasma samples the microarray platform performs well across the range of total PSA levels. This assay might have the potential to substitute for the large-scale microtiter plate format in diagnostic applications. The duplex assay paves the way for a future quantitative multiplex assay, which analyses several prostate cancer biomarkers simultaneously. PMID:22921878

  14. Quantitative multi-color FRET measurements by Fourier lifetime excitation-emission matrix spectroscopy.

    PubMed

    Zhao, Ming; Huang, Run; Peng, Leilei

    2012-11-19

    Förster resonant energy transfer (FRET) is extensively used to probe macromolecular interactions and conformation changes. The established FRET lifetime analysis method measures the FRET process through its effect on the donor lifetime. In this paper we present a method that directly probes the time-resolved FRET signal with frequency domain Fourier lifetime excitation-emission matrix (FLEEM) measurements. FLEEM separates fluorescent signals by their different phonon energy pathways from excitation to emission. The FRET process generates a unique signal channel that is initiated by donor excitation but ends with acceptor emission. Time-resolved analysis of the FRET EEM channel allows direct measurements on the FRET process, unaffected by free fluorophores that might be present in the sample. Together with time-resolved analysis on non-FRET channels, i.e. donor and acceptor EEM channels, time resolved EEM analysis allows precise quantification of FRET in the presence of free fluorophores. The method is extended to three-color FRET processes, where quantification with traditional methods remains challenging because of the significantly increased complexity in the three-way FRET interactions. We demonstrate the time-resolved EEM analysis method with quantification of three-color FRET in incompletely hybridized triple-labeled DNA oligonucleotides. Quantitative measurements of the three-color FRET process in triple-labeled dsDNA are obtained in the presence of free single-labeled ssDNA and double-labeled dsDNA. The results establish a quantification method for studying multi-color FRET between multiple macromolecules in biochemical equilibrium.

  15. Quantitative multi-color FRET measurements by Fourier lifetime excitation-emission matrix spectroscopy

    PubMed Central

    Zhao, Ming; Huang, Run; Peng, Leilei

    2012-01-01

    Förster resonant energy transfer (FRET) is extensively used to probe macromolecular interactions and conformation changes. The established FRET lifetime analysis method measures the FRET process through its effect on the donor lifetime. In this paper we present a method that directly probes the time-resolved FRET signal with frequency domain Fourier lifetime excitation-emission matrix (FLEEM) measurements. FLEEM separates fluorescent signals by their different phonon energy pathways from excitation to emission. The FRET process generates a unique signal channel that is initiated by donor excitation but ends with acceptor emission. Time-resolved analysis of the FRET EEM channel allows direct measurements on the FRET process, unaffected by free fluorophores that might be present in the sample. Together with time-resolved analysis on non-FRET channels, i.e. donor and acceptor EEM channels, time resolved EEM analysis allows precise quantification of FRET in the presence of free fluorophores. The method is extended to three-color FRET processes, where quantification with traditional methods remains challenging because of the significantly increased complexity in the three-way FRET interactions. We demonstrate the time-resolved EEM analysis method with quantification of three-color FRET in incompletely hybridized triple-labeled DNA oligonucleotides. Quantitative measurements of the three-color FRET process in triple-labeled dsDNA are obtained in the presence of free single-labeled ssDNA and double-labeled dsDNA. The results establish a quantification method for studying multi-color FRET between multiple macromolecules in biochemical equilibrium. PMID:23187535

  16. Assessment and Mission Planning Capability For Quantitative Aerothermodynamic Flight Measurements Using Remote Imaging

    NASA Technical Reports Server (NTRS)

    Horvath, Thomas; Splinter, Scott; Daryabeigi, Kamran; Wood, William; Schwartz, Richard; Ross, Martin

    2008-01-01

    High resolution calibrated infrared imagery of vehicles during hypervelocity atmospheric entry or sustained hypersonic cruise has the potential to provide flight data on the distribution of surface temperature and the state of the airflow over the vehicle. In the early 1980 s NASA sought to obtain high spatial resolution infrared imagery of the Shuttle during entry. Despite mission execution with a technically rigorous pre-planning capability, the single airborne optical system for this attempt was considered developmental and the scientific return was marginal. In 2005 the Space Shuttle Program again sponsored an effort to obtain imagery of the Orbiter. Imaging requirements were targeted towards Shuttle ascent; companion requirements for entry did not exist. The engineering community was allowed to define observation goals and incrementally demonstrate key elements of a quantitative spatially resolved measurement capability over a series of flights. These imaging opportunities were extremely beneficial and clearly demonstrated capability to capture infrared imagery with mature and operational assets of the US Navy and the Missile Defense Agency. While successful, the usefulness of the imagery was, from an engineering perspective, limited. These limitations were mainly associated with uncertainties regarding operational aspects of data acquisition. These uncertainties, in turn, came about because of limited pre-flight mission planning capability, a poor understanding of several factors including the infrared signature of the Shuttle, optical hardware limitations, atmospheric effects and detector response characteristics. Operational details of sensor configuration such as detector integration time and tracking system algorithms were carried out ad hoc (best practices) which led to low probability of target acquisition and detector saturation. Leveraging from the qualified success during Return-to-Flight, the NASA Engineering and Safety Center sponsored an

  17. Quantitative measurement of electron number in nanosecond and picosecond laser-induced air breakdown

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Yue; Sawyer, Jordan C.; Su, Liu

    2016-05-07

    Here we present quantitative measurements of total electron numbers in laser-induced air breakdown at pressures ranging from atmospheric to 40 bar{sub g} by 10 ns and 100 ps laser pulses. A quantifiable definition for the laser-induced breakdown threshold is identified by a sharp increase in the measurable total electron numbers via dielectric-calibrated coherent microwave scattering. For the 10 ns laser pulse, the threshold of laser-induced breakdown in atmospheric air is defined as the total electron number of ∼10{sup 6}. This breakdown threshold decreases with an increase of pressure and laser photon energy (shorter wavelength), which is consistent with the theory of initialmore » multiphoton ionization and subsequent avalanche processes. For the 100 ps laser pulse cases, a clear threshold is not present and only marginal pressure effects can be observed, which is due to the short pulse duration leading to stronger multiphoton ionization and minimal collisional avalanche ionization.« less

  18. Quantitative measurement of carbon nanotubes released from their composites by thermal carbon analysis

    NASA Astrophysics Data System (ADS)

    Ogura, I.; Kotake, M.; Ata, S.; Honda, K.

    2017-06-01

    The release of free carbon nanotubes (CNTs) and CNTs partly embedded in matrix debris into the air may occur during mechanical and abrasion processes involving CNT composites. Since the harmful effects of CNT-matrix mixtures have not yet been fully evaluated, it is considered that any exposure to CNTs, including CNT-matrix mixtures, should be measured and controlled. Thermal carbon analysis, such as Method 5040 of the National Institute for Occupational Safety and Health, is one of the most reliable quantitative methods for measuring CNTs in the air. However, when CNTs are released together with polymer matrices, this technique may be inapplicable. In this study, we evaluated the potential for using thermal carbon analysis to determine CNTs in the presence of polymer matrices. Our results showed that thermal carbon analysis was potentially capable of determining CNTs in distinction from polyamide 12, polybutylene terephthalate, polypropylene, and polyoxymethylene. However, it was difficult to determine CNTs in the presence of polyethylene terephthalate, polycarbonate, polyetheretherketone, or polyamide 6.

  19. Friedreich and dominant ataxias: quantitative differences in cerebellar dysfunction measurements.

    PubMed

    Tanguy Melac, Audrey; Mariotti, Caterina; Filipovic Pierucci, Antoine; Giunti, Paola; Arpa, Javier; Boesch, Sylvia; Klopstock, Thomas; Müller Vom Hagen, Jennifer; Klockgether, Thomas; Bürk, Katrin; Schulz, Jörg B; Reetz, Kathrin; Pandolfo, Massimo; Durr, Alexandra; Tezenas du Montcel, Sophie

    2018-06-01

    Sensitive outcome measures for clinical trials on cerebellar ataxias are lacking. Most cerebellar ataxias progress very slowly and quantitative measurements are required to evaluate cerebellar dysfunction. We evaluated two scales for rating cerebellar ataxias: the Composite Cerebellar Functional Severity (CCFS) Scale and Scale for the Assessment and Rating of Ataxia (SARA), in patients with spinocerebellar ataxia (SCA) and controls. We evaluated these scales for different diseases and investigated the factors governing the scores obtained. All patients were recruited prospectively. There were 383 patients with Friedreich's ataxia (FRDA), 205 patients with SCA and 168 controls. In FRDA, 31% of the variance of cerebellar signs with the CCFS and 41% of that with SARA were explained by disease duration, age at onset and the shorter abnormal repeat in the FXN gene. Increases in CCFS and SARA scores per year were lower for FRDA than for SCA (CCFS index: 0.123±0.123 per year vs 0.163±0.179, P<0.001; SARA index: 1.5±1.2 vs 1.7±1.7, P<0.001), indicating slower cerebellar dysfunction indexes for FRDA than for SCA. Patients with SCA2 had higher CCFS scores than patients with SCA1 and SCA3, but similar SARA scores. Cerebellar dysfunction, as measured with the CCFS and SARA scales, was more severe in FRDA than in patients with SCA, but with lower progression indexes, within the limits of these types of indexes. Ceiling effects may occur at late stages, for both scales. The CCFS scale is rater-independent and could be used in a multicentre context, as it is simple, rapid and fully automated. ClinicalTrials.gov: NCT02069509. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. AUTORADIOGRAPHIC ANALYSIS ON AGAR PLATES OF ANTIGENS FROM SUB CELLULAR FRACTIONS OF RAT LIVER SLICES

    PubMed Central

    Morgan, W. S.; Perlmann, P.; Hultin, T.

    1961-01-01

    Slices of rat livers were incubated with 14C amino acids, homogenized, and subjected to differential centrifugation. The microsomes were further extracted with the non-ionic detergent Lubrol W and with EDTA. These extracts and the microsome free "cell sap," freed from the pH 5 precipitable fraction, were subsequently reacted with antisera using agar diffusion techniques. The antisera employed were obtained from rabbits injected with different subcellular fractions of rat liver or with rat serum proteins. When the agar diffusion plates were autoradiographed it was found that some of the precipitates were radioactive while others were not. Control experiments indicated that this labeling was due to the specific incorporation of 14C amino acids into various rat liver antigens during incubation of the slices rather than to a non-specific adsorption of radioactive material to the immunological precipitates. When the slices were incubated with the isotope for up to 30 minutes, the serum proteins which could be extracted from the microsomes with the detergent were strongly labeled, as were a number of additional microsomal antigens of unknown significance. In contrast, the serum proteins present in the cell sap were only weakly labeled. Most of the typical cell sap proteins, both those precipitable and those soluble at pH 5, seemed to remain unlabeled. No consistently reproducible results were obtained with the EDTA extracts of the ribosomal residues remaining after extraction of the microsomes with the detergent. Incubation of the liver slices for longer periods (up to 120 minutes) led to a strong labeling of the serum proteins in the cell sap as well as to the appearance of labeling in additional cell sap proteins. The results are discussed with regard to the subcellular site of synthesis and the metabolism of the different antigens. PMID:13772607

  1. Universality and predictability in molecular quantitative genetics.

    PubMed

    Nourmohammad, Armita; Held, Torsten; Lässig, Michael

    2013-12-01

    Molecular traits, such as gene expression levels or protein binding affinities, are increasingly accessible to quantitative measurement by modern high-throughput techniques. Such traits measure molecular functions and, from an evolutionary point of view, are important as targets of natural selection. We review recent developments in evolutionary theory and experiments that are expected to become building blocks of a quantitative genetics of molecular traits. We focus on universal evolutionary characteristics: these are largely independent of a trait's genetic basis, which is often at least partially unknown. We show that universal measurements can be used to infer selection on a quantitative trait, which determines its evolutionary mode of conservation or adaptation. Furthermore, universality is closely linked to predictability of trait evolution across lineages. We argue that universal trait statistics extends over a range of cellular scales and opens new avenues of quantitative evolutionary systems biology. Copyright © 2013. Published by Elsevier Ltd.

  2. Quantitative Targeted Proteomics and Electrochromic Shift for Measuring Photosystem Content of Marine Phytoplankton

    NASA Astrophysics Data System (ADS)

    Brown, C. M.; Bailleul, B.; Melanson, J. R.; Campbell, D. A.; Cockshutt, A. M.; Cardol, P.

    2016-02-01

    Abundance and stoichiometry data for the photosystems, the intersystem electron transport complexes and the Calvin cycle enzymes are rich in information about light and nutrient acclimation. Quantifying these complexes is essential for understanding limitations on and capacities for photosynthesis. Targeted quantitative immunodetections of conserved subunits (eg. PsbA for PSII; PsaC for PSI) are becoming an established method for absolute measurement of these complexes. An advantage of protein measurements is that they can be done with non-living flash-frozen samples and processed post-field. A pitfall of physical versus functional measures is that in some scenarios, such as during photoinhibition of photosystem II (PSII), physical and functional measures give different values, but such disparities are often meaningful, informing targeted studies of regulation, repair and enzyme kinetics. Electrochromic Shift (ECS) is an alternative, fast and noninvasive method which can be exploited to determine functional PSI:PSII ratios in living cells. The basis for ECS is that pigments in the photosynthetic membrane exhibit a shift in their absorption spectra when the electric component of the proton motive force is generated across the membrane in the light. Cross-validation of methods by independent measures builds confidence in results from both approaches and can be useful for ground truthing of underway or high-throughput optical measurements or functional measurements from bioassays. We present comparative data from immunoquantitation and ECS for an array of diatom taxa. The physical data fall within established ranges. The basis for similarities and disparities in the photosystem stoichiometries between the methods are discussed.

  3. Breach Risk Magnitude: A Quantitative Measure of Database Security.

    PubMed

    Yasnoff, William A

    2016-01-01

    A quantitative methodology is described that provides objective evaluation of the potential for health record system breaches. It assumes that breach risk increases with the number of potential records that could be exposed, while it decreases when more authentication steps are required for access. The breach risk magnitude (BRM) is the maximum value for any system user of the common logarithm of the number of accessible database records divided by the number of authentication steps needed to achieve such access. For a one million record relational database, the BRM varies from 5.52 to 6 depending on authentication protocols. For an alternative data architecture designed specifically to increase security by separately storing and encrypting each patient record, the BRM ranges from 1.3 to 2.6. While the BRM only provides a limited quantitative assessment of breach risk, it may be useful to objectively evaluate the security implications of alternative database organization approaches.

  4. High Throughput Measurement of Extracellular DNA Release and Quantitative NET Formation in Human Neutrophils In Vitro.

    PubMed

    Sil, Payel; Yoo, Dae-Goon; Floyd, Madison; Gingerich, Aaron; Rada, Balazs

    2016-06-18

    Neutrophil granulocytes are the most abundant leukocytes in the human blood. Neutrophils are the first to arrive at the site of infection. Neutrophils developed several antimicrobial mechanisms including phagocytosis, degranulation and formation of neutrophil extracellular traps (NETs). NETs consist of a DNA scaffold decorated with histones and several granule markers including myeloperoxidase (MPO) and human neutrophil elastase (HNE). NET release is an active process involving characteristic morphological changes of neutrophils leading to expulsion of their DNA into the extracellular space. NETs are essential to fight microbes, but uncontrolled release of NETs has been associated with several disorders. To learn more about the clinical relevance and the mechanism of NET formation, there is a need to have reliable tools capable of NET quantitation. Here three methods are presented that can assess NET release from human neutrophils in vitro. The first one is a high throughput assay to measure extracellular DNA release from human neutrophils using a membrane impermeable DNA-binding dye. In addition, two other methods are described capable of quantitating NET formation by measuring levels of NET-specific MPO-DNA and HNE-DNA complexes. These microplate-based methods in combination provide great tools to efficiently study the mechanism and regulation of NET formation of human neutrophils.

  5. Distance measures and optimization spaces in quantitative fatty acid signature analysis

    USGS Publications Warehouse

    Bromaghin, Jeffrey F.; Rode, Karyn D.; Budge, Suzanne M.; Thiemann, Gregory W.

    2015-01-01

    Quantitative fatty acid signature analysis has become an important method of diet estimation in ecology, especially marine ecology. Controlled feeding trials to validate the method and estimate the calibration coefficients necessary to account for differential metabolism of individual fatty acids have been conducted with several species from diverse taxa. However, research into potential refinements of the estimation method has been limited. We compared the performance of the original method of estimating diet composition with that of five variants based on different combinations of distance measures and calibration-coefficient transformations between prey and predator fatty acid signature spaces. Fatty acid signatures of pseudopredators were constructed using known diet mixtures of two prey data sets previously used to estimate the diets of polar bears Ursus maritimus and gray seals Halichoerus grypus, and their diets were then estimated using all six variants. In addition, previously published diets of Chukchi Sea polar bears were re-estimated using all six methods. Our findings reveal that the selection of an estimation method can meaningfully influence estimates of diet composition. Among the pseudopredator results, which allowed evaluation of bias and precision, differences in estimator performance were rarely large, and no one estimator was universally preferred, although estimators based on the Aitchison distance measure tended to have modestly superior properties compared to estimators based on the Kullback-Leibler distance measure. However, greater differences were observed among estimated polar bear diets, most likely due to differential estimator sensitivity to assumption violations. Our results, particularly the polar bear example, suggest that additional research into estimator performance and model diagnostics is warranted.

  6. Autoradiographic distribution of /sup 14/C-labeled 3H-imidazo(4,5-f)quinoline-2-amines in mice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bergman, K.

    1985-03-01

    The highly mutagenic heterocyclic amines, 2-amino-3-methylimidazo(4,5-f)quinoline (IQ) and 2-amino-3,4-dimethylimidazo(4,5-f)quinoline (MeIQ), are formed during heating of protein-rich foods. In order to gain information about the distribution and fate of IQ and MeIQ in vivo, a whole-body autoradiographic study of i.v.-injected /sup 14/C-labeled IQ and MeIQ has been performed in male NMRI, pregnant NMRI, and female C3H mice. IQ and MeIQ showed similar distribution patterns. At short survival times, the autoradiograms were characterized by an accumulation of radioactivity in metabolic and excretory organs (liver, kidney, bile, urine, gastric and intestinal contents, salivary glands, nasal mucosa, and Harder's gland), as well as inmore » lymphomyeloid tissues (bone marrow, thymus, spleen and lymph nodes) and in endocrine and reproductive tissues (adrenal medulla, pancreatic islets, thyroid, hypophysis, testis, epididymis, seminal vesicles, ampulla, and prostate). The liver and kidney cortex were identified as sites of retention of nonextractable radioactivity. IQ and MeIQ showed a strong affinity for melanin. IQ and MeIQ passed the placenta, but no radioactivity was retained in fetal tissues. The results pinpoint the liver as a site of IQ- and MeIQ-mediated toxicity. Future studies of IQ and MeIQ may be guided by and clarify the role of other tissue localizations in the toxicity of IQ and MeIQ.« less

  7. Surface temperature/heat transfer measurement using a quantitative phosphor thermography system

    NASA Technical Reports Server (NTRS)

    Buck, G. M.

    1991-01-01

    A relative-intensity phosphor thermography technique developed for surface heating studies in hypersonic wind tunnels is described. A direct relationship between relative emission intensity and phosphor temperature is used for quantitative surface temperature measurements in time. The technique provides global surface temperature-time histories using a 3-CCD (Charge Coupled Device) video camera and digital recording system. A current history of technique development at Langley is discussed. Latest developments include a phosphor mixture for a greater range of temperature sensitivity and use of castable ceramics for inexpensive test models. A method of calculating surface heat-transfer from thermal image data in blowdown wind tunnels is included in an appendix, with an analysis of material thermal heat-transfer properties. Results from tests in the Langley 31-Inch Mach 10 Tunnel are presented for a ceramic orbiter configuration and a four-inch diameter hemisphere model. Data include windward heating for bow-shock/wing-shock interactions on the orbiter wing surface, and a comparison with prediction for hemisphere heating distribution.

  8. Comparison of microfluidic digital PCR and conventional quantitative PCR for measuring copy number variation.

    PubMed

    Whale, Alexandra S; Huggett, Jim F; Cowen, Simon; Speirs, Valerie; Shaw, Jacqui; Ellison, Stephen; Foy, Carole A; Scott, Daniel J

    2012-06-01

    One of the benefits of Digital PCR (dPCR) is the potential for unparalleled precision enabling smaller fold change measurements. An example of an assessment that could benefit from such improved precision is the measurement of tumour-associated copy number variation (CNV) in the cell free DNA (cfDNA) fraction of patient blood plasma. To investigate the potential precision of dPCR and compare it with the established technique of quantitative PCR (qPCR), we used breast cancer cell lines to investigate HER2 gene amplification and modelled a range of different CNVs. We showed that, with equal experimental replication, dPCR could measure a smaller CNV than qPCR. As dPCR precision is directly dependent upon both the number of replicate measurements and the template concentration, we also developed a method to assist the design of dPCR experiments for measuring CNV. Using an existing model (based on Poisson and binomial distributions) to derive an expression for the variance inherent in dPCR, we produced a power calculation to define the experimental size required to reliably detect a given fold change at a given template concentration. This work will facilitate any future translation of dPCR to key diagnostic applications, such as cancer diagnostics and analysis of cfDNA.

  9. Peripheral Quantitative Computed Tomography: Measurement Sensitivity in Persons With and Without Spinal Cord Injury

    PubMed Central

    Shields, Richard K.; Dudley-Javoroski, Shauna; Boaldin, Kathryn M.; Corey, Trent A.; Fog, Daniel B.; Ruen, Jacquelyn M.

    2012-01-01

    Objectives To determine (1) the error attributable to external tibia-length measurements by using peripheral quantitative computed tomography (pQCT) and (2) the effect these errors have on scan location and tibia trabecular bone mineral density (BMD) after spinal cord injury (SCI). Design Blinded comparison and criterion standard in matched cohorts. Setting Primary care university hospital. Participants Eight able-bodied subjects underwent tibia length measurement. A separate cohort of 7 men with SCI and 7 able-bodied age-matched male controls underwent pQCT analysis. Interventions Not applicable. Main Outcome Measures The projected worst-case tibia-length–measurement error translated into a pQCT slice placement error of ±3mm. We collected pQCT slices at the distal 4% tibia site, 3mm proximal and 3mm distal to that site, and then quantified BMD error attributable to slice placement. Results Absolute BMD error was greater for able-bodied than for SCI subjects (5.87mg/cm3 vs 4.5mg/cm3). However, the percentage error in BMD was larger for SCI than able-bodied subjects (4.56% vs 2.23%). Conclusions During cross-sectional studies of various populations, BMD differences up to 5% may be attributable to variation in limb-length–measurement error. PMID:17023249

  10. Targeted Quantitation of Proteins by Mass Spectrometry

    PubMed Central

    2013-01-01

    Quantitative measurement of proteins is one of the most fundamental analytical tasks in a biochemistry laboratory, but widely used immunochemical methods often have limited specificity and high measurement variation. In this review, we discuss applications of multiple-reaction monitoring (MRM) mass spectrometry, which allows sensitive, precise quantitative analyses of peptides and the proteins from which they are derived. Systematic development of MRM assays is permitted by databases of peptide mass spectra and sequences, software tools for analysis design and data analysis, and rapid evolution of tandem mass spectrometer technology. Key advantages of MRM assays are the ability to target specific peptide sequences, including variants and modified forms, and the capacity for multiplexing that allows analysis of dozens to hundreds of peptides. Different quantitative standardization methods provide options that balance precision, sensitivity, and assay cost. Targeted protein quantitation by MRM and related mass spectrometry methods can advance biochemistry by transforming approaches to protein measurement. PMID:23517332

  11. Targeted quantitation of proteins by mass spectrometry.

    PubMed

    Liebler, Daniel C; Zimmerman, Lisa J

    2013-06-04

    Quantitative measurement of proteins is one of the most fundamental analytical tasks in a biochemistry laboratory, but widely used immunochemical methods often have limited specificity and high measurement variation. In this review, we discuss applications of multiple-reaction monitoring (MRM) mass spectrometry, which allows sensitive, precise quantitative analyses of peptides and the proteins from which they are derived. Systematic development of MRM assays is permitted by databases of peptide mass spectra and sequences, software tools for analysis design and data analysis, and rapid evolution of tandem mass spectrometer technology. Key advantages of MRM assays are the ability to target specific peptide sequences, including variants and modified forms, and the capacity for multiplexing that allows analysis of dozens to hundreds of peptides. Different quantitative standardization methods provide options that balance precision, sensitivity, and assay cost. Targeted protein quantitation by MRM and related mass spectrometry methods can advance biochemistry by transforming approaches to protein measurement.

  12. Medical student attitudes towards older people: a critical review of quantitative measures.

    PubMed

    Wilson, Mark A G; Kurrle, Susan; Wilson, Ian

    2018-01-24

    Further research into medical student attitudes towards older people is important, and requires accurate and detailed evaluative methodology. The two objectives for this paper are: (1) From the literature, to critically review instruments of measure for medical student attitudes towards older people, and (2) To recommend the most appropriate quantitative instrument for future research into medical student attitudes towards older people. A SCOPUS and Ovid cross search was performed using the keywords Attitude and medical student and aged or older or elderly. This search was supplemented by manual searching, guided by citations in articles identified by the initial literature search, using the SCOPUS and PubMed databases. International studies quantifying medical student attitudes have demonstrated neutral to positive attitudes towards older people, using various instruments. The most commonly used instruments are the Ageing Semantic Differential (ASD) and the University of California Los Angeles Geriatric Attitudes Scale, with several other measures occasionally used. All instruments used to date have inherent weaknesses. A reliable and valid instrument with which to quantify modern medical student attitudes towards older people has not yet been developed. Adaptation of the ASD for contemporary usage is recommended.

  13. A novel Raman spectrophotometric method for quantitative measurement of nucleoside triphosphate hydrolysis.

    PubMed

    Jenkins, R H; Tuma, R; Juuti, J T; Bamford, D H; Thomas, G J

    1999-01-01

    A novel spectrophotometric method, based upon Raman spectroscopy, has been developed for accurate quantitative determination of nucleoside triphosphate phosphohydrolase (NTPase) activity. The method relies upon simultaneous measurement in real time of the intensities of Raman marker bands diagnostic of the triphosphate (1115 cm(-1)) and diphosphate (1085 cm(-1)) moieties of the NTPase substrate and product, respectively. The reliability of the method is demonstrated for the NTPase-active RNA-packaging enzyme (protein P4) of bacteriophage phi6, for which comparative NTPase activities have been estimated independently by radiolabeling assays. The Raman-determined rate for adenosine triphosphate substrate (8.6 +/- 1.3 micromol x mg(-1) x min(-1) at 40 degrees C) is in good agreement with previous estimates. The versatility of the Raman method is demonstrated by its applicability to a variety of nucleotide substrates of P4, including the natural ribonucleoside triphosphates (ATP, GTP) and dideoxynucleoside triphosphates (ddATP, ddGTP). Advantages of the present protocol include conservative sample requirements (approximately 10(-6) g enzyme/protocol) and relative ease of data collection and analysis. The latter conveniences are particularly advantageous for the measurement of activation energies of phosphohydrolase activity.

  14. MK-801-induced locomotor activity in long-sleep x short-sleep recombinant inbred mouse strains: correlational analysis with low-dose ethanol and provisional quantitative trait loci.

    PubMed

    Zahniser, N R; Negri, C A; Hanania, T; Gehle, V M

    1999-11-01

    Low doses of the N-methyl-D-aspartate receptor (NMDAR) antagonist MK-801 (dizocilpine) or ethanol increase locomotor activity to a lesser extent in long-sleep (LS), than in short-sleep (SS), mice. LS mice also have fewer brain [3H]MK-801 binding sites than SS mice. In this study, LSXSS recombinant inbred (RI) mice were used to investigate whether different NMDAR densities contribute to differential MK-801 activation and whether common genes are involved in initial sensitivity to MK-801-and ethanol-induced activation. Locomotor activity was measured for 90 min after saline or MK-801 injection. Quantitative autoradiographic analysis of [3H]MK-801 binding was used to measure densities of NMDARs in seven brain regions. The ethanol (1-2 g/kg) activation scores from Erwin and colleagues (1997) were used for correlational analysis, as was their method for quantitative trait loci (QTL) analysis. Both saline and MK-801 (0.3 mg/kg, given intraperitoneally) induced a continuum of locomotor responses across the LSXSS RI strains. There was a 4-fold range of MK-801 difference scores (MK-801 score-saline baseline), with the RI 9 and RI 4 strains representing low and high responders, respectively. Dose-response experiments with these two strains confirmed that 0.3 mg/kg MK-801 produced significant activation, similar to previous results with LS and SS mice. However, unlike previous LS/SS results, lower densities of NMDARs were not observed in the RI 9 than in the RI 4 mouse brains. No significant genetic correlations were observed between MK-801-induced and ethanol-induced responses in the LSXSS RI mice. Two provisional MK-801 activation QTLs were identified (p < 0.01) on chromosomes 11 and 19, neither in common with those mapped for ethanol activation. Different densities of brain NMDARs are unlikely to account for the differential activation of LSXSS RI mice by MK-801. Additionally, in the RI mice either separate sets of genes regulate low dose MK-801- and ethanol

  15. Acute effects of moclobemide and deprenyl on 5-HT synthesis rates in the rat brain: An autoradiographic study.

    PubMed

    Nishi, Kyoko; Mück-Seler, Dorotea; Hasegawa, Shu; Watanabe, Arata; Diksic, Mirko

    2006-10-16

    Serotonin (5-HT), norepinephrine (NE) and dopamine (DA) released from nerve terminals in the brain are primarily removed from the synaptic cleft by a reuptake mechanism. In part, the homeostasis is maintained by monoamine oxidase (MAO) deamination achieved primarily intracellularly. The present study's aim was to examine the effect of the acute administration of the MAO inhibitors, moclobemide (a MAO-A inhibitor) and deprenyl (a MAO-B inhibitor), on 5-HT synthesis rates, measured in discrete regions of the rat brain by an autoradiographic method, using alpha-[14C]methyl-l-tryptophan as a tracer. MAO inhibitors have different effects on 5-HT synthesis rates in the cell bodies and areas of the nerve terminals. Moclobemide (10 mg/kg, i.p. 30 min before the tracer injection) and deprenyl (3 mg/kg, i.p. 2 h before the tracer injection) decreased the 5-HT synthesis rates in the dorsal (-18% and -22%) and median (-22% and -33%) raphe, respectively. Moclobemide also significantly decreased 5-HT synthesis in the entire nerve terminal areas investigated. The reductions were between 23% (cingulate cortex) and 50% (locus coeruleus). Deprenyl did not significantly affect 5-HT synthesis in the nerve terminals. The present results suggest that MAO-A, and to a lesser extent, MAO-B, are involved in the regulation of 5-HT synthesis in the rat brain. The mechanism(s) of MAO inhibitors' action on 5-HT synthesis in the raphe nuclei are probably related to an increase in the extraneuronal 5-HT concentration and also to the interaction between the serotonergic and catecholaminergic neurons. The reduction of 5-HT synthesis in the raphe nuclei likely occurs by an action of extracellular 5-HT via the dendritic autoreceptors with a possible contribution from the action of extracellular DA and NE. In the terminal regions, the most likely mechanism is via the presynaptic autoreceptors through which elevated extraneuronal 5-HT acts on synthesis control. However, there is also a possibility that

  16. Scanning transmission ion microscopy mass measurements for quantitative trace element analysis within biological samples and validation using atomic force microscopy thickness measurements

    NASA Astrophysics Data System (ADS)

    Devès, Guillaume; Cohen-Bouhacina, Touria; Ortega, Richard

    2004-10-01

    We used the nuclear microprobe techniques, micro-PIXE (particle-induced X-ray emission), micro-RBS (Rutherford backscattering spectrometry) and scanning transmission ion microscopy (STIM) in order to perform the characterization of trace element content and spatial distribution within biological samples (dehydrated cultured cells, tissues). The normalization of PIXE results was usually expressed in terms of sample dry mass as determined by micro-RBS recorded simultaneously to micro-PIXE. However, the main limit of RBS mass measurement is the sample mass loss occurring during irradiation and which could be up to 30% of the initial sample mass. We present here a new methodology for PIXE normalization and quantitative analysis of trace element within biological samples based on dry mass measurement performed by mean of STIM. The validation of STIM cell mass measurements was obtained in comparison with AFM sample thickness measurements. Results indicated the reliability of STIM mass measurement performed on biological samples and suggested that STIM should be performed for PIXE normalization. Further information deriving from direct confrontation of AFM and STIM analysis could as well be obtained, like in situ measurements of cell specific gravity within cells compartment (nucleolus and cytoplasm).

  17. Applying Quantitative Genetic Methods to Primate Social Behavior

    PubMed Central

    Brent, Lauren J. N.

    2013-01-01

    Increasingly, behavioral ecologists have applied quantitative genetic methods to investigate the evolution of behaviors in wild animal populations. The promise of quantitative genetics in unmanaged populations opens the door for simultaneous analysis of inheritance, phenotypic plasticity, and patterns of selection on behavioral phenotypes all within the same study. In this article, we describe how quantitative genetic techniques provide studies of the evolution of behavior with information that is unique and valuable. We outline technical obstacles for applying quantitative genetic techniques that are of particular relevance to studies of behavior in primates, especially those living in noncaptive populations, e.g., the need for pedigree information, non-Gaussian phenotypes, and demonstrate how many of these barriers are now surmountable. We illustrate this by applying recent quantitative genetic methods to spatial proximity data, a simple and widely collected primate social behavior, from adult rhesus macaques on Cayo Santiago. Our analysis shows that proximity measures are consistent across repeated measurements on individuals (repeatable) and that kin have similar mean measurements (heritable). Quantitative genetics may hold lessons of considerable importance for studies of primate behavior, even those without a specific genetic focus. PMID:24659839

  18. Electron Paramagnetic Resonance Oximetry as a Quantitative Method to Measure Cellular Respiration: A Consideration of Oxygen Diffusion Interference

    PubMed Central

    Presley, Tennille; Kuppusamy, Periannan; Zweier, Jay L.; Ilangovan, Govindasamy

    2006-01-01

    Electron paramagnetic resonance (EPR) oximetry is being widely used to measure the oxygen consumption of cells, mitochondria, and submitochondrial particles. However, further improvement of this technique, in terms of data analysis, is required to use it as a quantitative tool. Here, we present a new approach for quantitative analysis of cellular respiration using EPR oximetry. The course of oxygen consumption by cells in suspension has been observed to have three distinct zones: pO2-independent respiration at higher pO2 ranges, pO2-dependent respiration at low pO2 ranges, and a static equilibrium with no change in pO2 at very low pO2 values. The approach here enables one to comprehensively analyze all of the three zones together—where the progression of O2 diffusion zones around each cell, their overlap within time, and their potential impact on the measured pO2 data are considered. The obtained results agree with previously established methods such as high-resolution respirometry measurements. Additionally, it is also demonstrated how the diffusion limitations can depend on cell density and consumption rate. In conclusion, the new approach establishes a more accurate and meaningful model to evaluate the EPR oximetry data on cellular respiration to quantify related parameters using EPR oximetry. PMID:17012319

  19. Electron paramagnetic resonance oximetry as a quantitative method to measure cellular respiration: a consideration of oxygen diffusion interference.

    PubMed

    Presley, Tennille; Kuppusamy, Periannan; Zweier, Jay L; Ilangovan, Govindasamy

    2006-12-15

    Electron paramagnetic resonance (EPR) oximetry is being widely used to measure the oxygen consumption of cells, mitochondria, and submitochondrial particles. However, further improvement of this technique, in terms of data analysis, is required to use it as a quantitative tool. Here, we present a new approach for quantitative analysis of cellular respiration using EPR oximetry. The course of oxygen consumption by cells in suspension has been observed to have three distinct zones: pO(2)-independent respiration at higher pO(2) ranges, pO(2)-dependent respiration at low pO(2) ranges, and a static equilibrium with no change in pO(2) at very low pO(2) values. The approach here enables one to comprehensively analyze all of the three zones together-where the progression of O(2) diffusion zones around each cell, their overlap within time, and their potential impact on the measured pO(2) data are considered. The obtained results agree with previously established methods such as high-resolution respirometry measurements. Additionally, it is also demonstrated how the diffusion limitations can depend on cell density and consumption rate. In conclusion, the new approach establishes a more accurate and meaningful model to evaluate the EPR oximetry data on cellular respiration to quantify related parameters using EPR oximetry.

  20. Listening to light scattering in turbid media: quantitative optical scattering imaging using photoacoustic measurements with one-wavelength illumination

    NASA Astrophysics Data System (ADS)

    Yuan, Zhen; Li, Xiaoqi; Xi, Lei

    2014-06-01

    Biomedical photoacoustic tomography (PAT), as a potential imaging modality, can visualize tissue structure and function with high spatial resolution and excellent optical contrast. It is widely recognized that the ability of quantitatively imaging optical absorption and scattering coefficients from photoacoustic measurements is essential before PAT can become a powerful imaging modality. Existing quantitative PAT (qPAT), while successful, has been focused on recovering absorption coefficient only by assuming scattering coefficient a constant. An effective method for photoacoustically recovering optical scattering coefficient is presently not available. Here we propose and experimentally validate such a method for quantitative scattering coefficient imaging using photoacoustic data from one-wavelength illumination. The reconstruction method developed combines conventional PAT with the photon diffusion equation in a novel way to realize the recovery of scattering coefficient. We demonstrate the method using various objects having scattering contrast only or both absorption and scattering contrasts embedded in turbid media. The listening-to-light-scattering method described will be able to provide high resolution scattering imaging for various biomedical applications ranging from breast to brain imaging.

  1. Sensitivity, stability, and precision of quantitative Ns-LIBS-based fuel-air-ratio measurements for methane-air flames at 1-11 bar.

    PubMed

    Hsu, Paul S; Gragston, Mark; Wu, Yue; Zhang, Zhili; Patnaik, Anil K; Kiefer, Johannes; Roy, Sukesh; Gord, James R

    2016-10-01

    Nanosecond laser-induced breakdown spectroscopy (ns-LIBS) is employed for quantitative local fuel-air (F/A) ratio (i.e., ratio of actual fuel-to-oxidizer mass over ratio of fuel-to-oxidizer mass at stoichiometry, measurements in well-characterized methane-air flames at pressures of 1-11 bar). We selected nitrogen and hydrogen atomic-emission lines at 568 nm and 656 nm, respectively, to establish a correlation between the line intensities and the F/A ratio. We have investigated the effects of laser-pulse energy, camera gate delay, and pressure on the sensitivity, stability, and precision of the quantitative ns-LIBS F/A ratio measurements. We determined the optimal laser energy and camera gate delay for each pressure condition and found that measurement stability and precision are degraded with an increase in pressure. We have identified primary limitations of the F/A ratio measurement employing ns-LIBS at elevated pressures as instabilities caused by the higher density laser-induced plasma and the presence of the higher level of soot. Potential improvements are suggested.

  2. Modern quantitative schlieren techniques

    NASA Astrophysics Data System (ADS)

    Hargather, Michael; Settles, Gary

    2010-11-01

    Schlieren optical techniques have traditionally been used to qualitatively visualize refractive flowfields in transparent media. Modern schlieren optics, however, are increasingly focused on obtaining quantitative information such as temperature and density fields in a flow -- once the sole purview of interferometry -- without the need for coherent illumination. Quantitative data are obtained from schlieren images by integrating the measured refractive index gradient to obtain the refractive index field in an image. Ultimately this is converted to a density or temperature field using the Gladstone-Dale relationship, an equation of state, and geometry assumptions for the flowfield of interest. Several quantitative schlieren methods are reviewed here, including background-oriented schlieren (BOS), schlieren using a weak lens as a "standard," and "rainbow schlieren." Results are presented for the application of these techniques to measure density and temperature fields across a supersonic turbulent boundary layer and a low-speed free-convection boundary layer in air. Modern equipment, including digital cameras, LED light sources, and computer software that make this possible are also discussed.

  3. Validating Quantitative Measurement Using Qualitative Data: Combining Rasch Scaling and Latent Semantic Analysis in Psychiatry

    NASA Astrophysics Data System (ADS)

    Lange, Rense

    2015-02-01

    An extension of concurrent validity is proposed that uses qualitative data for the purpose of validating quantitative measures. The approach relies on Latent Semantic Analysis (LSA) which places verbal (written) statements in a high dimensional semantic space. Using data from a medical / psychiatric domain as a case study - Near Death Experiences, or NDE - we established concurrent validity by connecting NDErs qualitative (written) experiential accounts with their locations on a Rasch scalable measure of NDE intensity. Concurrent validity received strong empirical support since the variance in the Rasch measures could be predicted reliably from the coordinates of their accounts in the LSA derived semantic space (R2 = 0.33). These coordinates also predicted NDErs age with considerable precision (R2 = 0.25). Both estimates are probably artificially low due to the small available data samples (n = 588). It appears that Rasch scalability of NDE intensity is a prerequisite for these findings, as each intensity level is associated (at least probabilistically) with a well- defined pattern of item endorsements.

  4. Quantitative Velocity Field Measurements in Reduced-Gravity Combustion Science and Fluid Physics Experiments

    NASA Technical Reports Server (NTRS)

    Greenberg, Paul S.; Wernet, Mark P.

    1999-01-01

    Systems have been developed and demonstrated for performing quantitative velocity measurements in reduced gravity combustion science and fluid physics investigations. The unique constraints and operational environments inherent to reduced-gravity experimental facilities pose special challenges to the development of hardware and software systems. Both point and planar velocimetric capabilities are described, with particular attention being given to the development of systems to support the International Space Station laboratory. Emphasis has been placed on optical methods, primarily arising from the sensitivity of the phenomena of interest to intrusive probes. Limitations on available power, volume, data storage, and attendant expertise have motivated the use of solid-state sources and detectors, as well as efficient analysis capabilities emphasizing interactive data display and parameter control.

  5. Feasibility of quantitative diffuse reflectance spectroscopy for targeted measurement of renal ischemia during laparoscopic partial nephrectomy.

    PubMed

    Goel, Utsav O; Maddox, Michael M; Elfer, Katherine N; Dorsey, Philip J; Wang, Mei; McCaslin, Ian Ross; Brown, J Quincy; Lee, Benjamin R

    2014-01-01

    Reduction of warm ischemia time during partial nephrectomy (PN) is critical to minimizing ischemic damage and improving postoperative kidney function, while maintaining tumor resection efficacy. Recently, methods for localizing the effects of warm ischemia to the region of the tumor via selective clamping of higher-order segmental artery branches have been shown to have superior outcomes compared with clamping the main renal artery. However, artery identification can prolong operative time and increase the blood loss and reduce the positive effects of selective ischemia. Quantitative diffuse reflectance spectroscopy (DRS) can provide a convenient, real-time means to aid in artery identification during laparoscopic PN. The feasibility of quantitative DRS for real-time longitudinal measurement of tissue perfusion and vascular oxygenation in laparoscopic nephrectomy was investigated in vivo in six Yorkshire swine kidneys (n=three animals ). DRS allowed for rapid identification of ischemic areas after selective vessel occlusion. In addition, the rates of ischemia induction and recovery were compared for main renal artery versus tertiary segmental artery occlusion, and it was found that the tertiary segmental artery occlusion trends toward faster recovery after ischemia, which suggests a potential benefit of selective ischemia. Quantitative DRS could provide a convenient and fast tool for artery identification and evaluation of the depth, spatial extent, and duration of selective tissue ischemia in laparoscopic PN.

  6. Feasibility of quantitative diffuse reflectance spectroscopy for targeted measurement of renal ischemia during laparoscopic partial nephrectomy

    NASA Astrophysics Data System (ADS)

    Goel, Utsav O.; Maddox, Michael M.; Elfer, Katherine N.; Dorsey, Philip J.; Wang, Mei; McCaslin, Ian Ross; Brown, J. Quincy; Lee, Benjamin R.

    2014-10-01

    Reduction of warm ischemia time during partial nephrectomy (PN) is critical to minimizing ischemic damage and improving postoperative kidney function, while maintaining tumor resection efficacy. Recently, methods for localizing the effects of warm ischemia to the region of the tumor via selective clamping of higher-order segmental artery branches have been shown to have superior outcomes compared with clamping the main renal artery. However, artery identification can prolong operative time and increase the blood loss and reduce the positive effects of selective ischemia. Quantitative diffuse reflectance spectroscopy (DRS) can provide a convenient, real-time means to aid in artery identification during laparoscopic PN. The feasibility of quantitative DRS for real-time longitudinal measurement of tissue perfusion and vascular oxygenation in laparoscopic nephrectomy was investigated in vivo in six Yorkshire swine kidneys (n=three animals). DRS allowed for rapid identification of ischemic areas after selective vessel occlusion. In addition, the rates of ischemia induction and recovery were compared for main renal artery versus tertiary segmental artery occlusion, and it was found that the tertiary segmental artery occlusion trends toward faster recovery after ischemia, which suggests a potential benefit of selective ischemia. Quantitative DRS could provide a convenient and fast tool for artery identification and evaluation of the depth, spatial extent, and duration of selective tissue ischemia in laparoscopic PN.

  7. Quantitative Measurement of Protease-Activity with Correction of Probe Delivery and Tissue Absorption Effects

    PubMed Central

    Salthouse, Christopher D.; Reynolds, Fred; Tam, Jenny M.; Josephson, Lee; Mahmood, Umar

    2009-01-01

    Proteases play important roles in a variety of pathologies from heart disease to cancer. Quantitative measurement of protease activity is possible using a novel spectrally matched dual fluorophore probe and a small animal lifetime imager. The recorded fluorescence from an activatable fluorophore, one that changes its fluorescent amplitude after biological target interaction, is also influenced by other factors including imaging probe delivery and optical tissue absorption of excitation and emission light. Fluorescence from a second spectrally matched constant (non-activatable) fluorophore on each nanoparticle platform can be used to correct for both probe delivery and tissue absorption. The fluorescence from each fluorophore is separated using fluorescence lifetime methods. PMID:20161242

  8. Speech graphs provide a quantitative measure of thought disorder in psychosis.

    PubMed

    Mota, Natalia B; Vasconcelos, Nivaldo A P; Lemos, Nathalia; Pieretti, Ana C; Kinouchi, Osame; Cecchi, Guillermo A; Copelli, Mauro; Ribeiro, Sidarta

    2012-01-01

    Psychosis has various causes, including mania and schizophrenia. Since the differential diagnosis of psychosis is exclusively based on subjective assessments of oral interviews with patients, an objective quantification of the speech disturbances that characterize mania and schizophrenia is in order. In principle, such quantification could be achieved by the analysis of speech graphs. A graph represents a network with nodes connected by edges; in speech graphs, nodes correspond to words and edges correspond to semantic and grammatical relationships. To quantify speech differences related to psychosis, interviews with schizophrenics, manics and normal subjects were recorded and represented as graphs. Manics scored significantly higher than schizophrenics in ten graph measures. Psychopathological symptoms such as logorrhea, poor speech, and flight of thoughts were grasped by the analysis even when verbosity differences were discounted. Binary classifiers based on speech graph measures sorted schizophrenics from manics with up to 93.8% of sensitivity and 93.7% of specificity. In contrast, sorting based on the scores of two standard psychiatric scales (BPRS and PANSS) reached only 62.5% of sensitivity and specificity. The results demonstrate that alterations of the thought process manifested in the speech of psychotic patients can be objectively measured using graph-theoretical tools, developed to capture specific features of the normal and dysfunctional flow of thought, such as divergence and recurrence. The quantitative analysis of speech graphs is not redundant with standard psychometric scales but rather complementary, as it yields a very accurate sorting of schizophrenics and manics. Overall, the results point to automated psychiatric diagnosis based not on what is said, but on how it is said.

  9. Methods for quantitative infrared directional-hemispherical and diffuse reflectance measurements using an FTIR and a commercial integrating sphere

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blake, Thomas A.; Johnson, Timothy J.; Tonkyn, Russell G.

    Infrared integrating sphere measurements of solid samples are important in providing reference data for contact, standoff and remote sensing applications. At the Pacific Northwest National Laboratory (PNNL) we have developed protocols to measure both the directional-hemispherical ( and diffuse (d) reflectances of powders, liquids, and disks of powders and solid materials using a commercially available, matte gold-coated integrating sphere and Fourier transform infrared spectrometer. Detailed descriptions of the sphere alignment and its use for making these reflectance measurements are given. Diffuse reflectance values were found to be dependent on the bidirectional reflection distribution function (BRDF) of the sample and themore » solid angle intercepted by the sphere’s specular exclusion port. To determine how well the sphere and protocols produce quantitative reflectance data, measurements were made of three diffuse and two specular standards prepared by the National institute of Standards and Technology (NIST, USA), LabSphere Infragold and Spectralon standards, hand-loaded sulfur and talc powder samples, and water. The five NIST standards behaved as expected: the three diffuse standards had a high degree of “diffuseness,” d/ = D > 0.9, whereas the two specular standards had D ≤ 0.03. The average absolute differences between the NIST and PNNL measurements of the NIST standards for both directional-hemispherical and diffuse reflectances are on the order of 0.01 reflectance units. Other quantitative differences between the PNNL-measured and calibration (where available) or literature reflectance values for these standards and materials are given and the possible origins of discrepancies are discussed. Random uncertainties and estimates of systematic uncertainties are presented. Corrections necessary to provide better agreement between the PNNL reflectance values as measured for the NIST standards and the NIST reflectance values for these same standards

  10. Large-Scale Interlaboratory Study to Develop, Analytically Validate and Apply Highly Multiplexed, Quantitative Peptide Assays to Measure Cancer-Relevant Proteins in Plasma*

    PubMed Central

    Abbatiello, Susan E.; Schilling, Birgit; Mani, D. R.; Zimmerman, Lisa J.; Hall, Steven C.; MacLean, Brendan; Albertolle, Matthew; Allen, Simon; Burgess, Michael; Cusack, Michael P.; Gosh, Mousumi; Hedrick, Victoria; Held, Jason M.; Inerowicz, H. Dorota; Jackson, Angela; Keshishian, Hasmik; Kinsinger, Christopher R.; Lyssand, John; Makowski, Lee; Mesri, Mehdi; Rodriguez, Henry; Rudnick, Paul; Sadowski, Pawel; Sedransk, Nell; Shaddox, Kent; Skates, Stephen J.; Kuhn, Eric; Smith, Derek; Whiteaker, Jeffery R.; Whitwell, Corbin; Zhang, Shucha; Borchers, Christoph H.; Fisher, Susan J.; Gibson, Bradford W.; Liebler, Daniel C.; MacCoss, Michael J.; Neubert, Thomas A.; Paulovich, Amanda G.; Regnier, Fred E.; Tempst, Paul; Carr, Steven A.

    2015-01-01

    There is an increasing need in biology and clinical medicine to robustly and reliably measure tens to hundreds of peptides and proteins in clinical and biological samples with high sensitivity, specificity, reproducibility, and repeatability. Previously, we demonstrated that LC-MRM-MS with isotope dilution has suitable performance for quantitative measurements of small numbers of relatively abundant proteins in human plasma and that the resulting assays can be transferred across laboratories while maintaining high reproducibility and quantitative precision. Here, we significantly extend that earlier work, demonstrating that 11 laboratories using 14 LC-MS systems can develop, determine analytical figures of merit, and apply highly multiplexed MRM-MS assays targeting 125 peptides derived from 27 cancer-relevant proteins and seven control proteins to precisely and reproducibly measure the analytes in human plasma. To ensure consistent generation of high quality data, we incorporated a system suitability protocol (SSP) into our experimental design. The SSP enabled real-time monitoring of LC-MRM-MS performance during assay development and implementation, facilitating early detection and correction of chromatographic and instrumental problems. Low to subnanogram/ml sensitivity for proteins in plasma was achieved by one-step immunoaffinity depletion of 14 abundant plasma proteins prior to analysis. Median intra- and interlaboratory reproducibility was <20%, sufficient for most biological studies and candidate protein biomarker verification. Digestion recovery of peptides was assessed and quantitative accuracy improved using heavy-isotope-labeled versions of the proteins as internal standards. Using the highly multiplexed assay, participating laboratories were able to precisely and reproducibly determine the levels of a series of analytes in blinded samples used to simulate an interlaboratory clinical study of patient samples. Our study further establishes that LC

  11. Determining Metacarpophalangeal Flexion Angle Tolerance for Reliable Volumetric Joint Space Measurements by High-resolution Peripheral Quantitative Computed Tomography.

    PubMed

    Tom, Stephanie; Frayne, Mark; Manske, Sarah L; Burghardt, Andrew J; Stok, Kathryn S; Boyd, Steven K; Barnabe, Cheryl

    2016-10-01

    The position-dependence of a method to measure the joint space of metacarpophalangeal (MCP) joints using high-resolution peripheral quantitative computed tomography (HR-pQCT) was studied. Cadaveric MCP were imaged at 7 flexion angles between 0 and 30 degrees. The variability in reproducibility for mean, minimum, and maximum joint space widths and volume measurements was calculated for increasing degrees of flexion. Root mean square coefficient of variance values were < 5% under 20 degrees of flexion for mean, maximum, and volumetric joint spaces. Values for minimum joint space width were optimized under 10 degrees of flexion. MCP joint space measurements should be acquired at < 10 degrees of flexion in longitudinal studies.

  12. A quantitative reconstruction software suite for SPECT imaging

    NASA Astrophysics Data System (ADS)

    Namías, Mauro; Jeraj, Robert

    2017-11-01

    Quantitative Single Photon Emission Tomography (SPECT) imaging allows for measurement of activity concentrations of a given radiotracer in vivo. Although SPECT has usually been perceived as non-quantitative by the medical community, the introduction of accurate CT based attenuation correction and scatter correction from hybrid SPECT/CT scanners has enabled SPECT systems to be as quantitative as Positron Emission Tomography (PET) systems. We implemented a software suite to reconstruct quantitative SPECT images from hybrid or dedicated SPECT systems with a separate CT scanner. Attenuation, scatter and collimator response corrections were included in an Ordered Subset Expectation Maximization (OSEM) algorithm. A novel scatter fraction estimation technique was introduced. The SPECT/CT system was calibrated with a cylindrical phantom and quantitative accuracy was assessed with an anthropomorphic phantom and a NEMA/IEC image quality phantom. Accurate activity measurements were achieved at an organ level. This software suite helps increasing quantitative accuracy of SPECT scanners.

  13. High temporal resolution dynamic contrast-enhanced MRI using compressed sensing-combined sequence in quantitative renal perfusion measurement.

    PubMed

    Chen, Bin; Zhao, Kai; Li, Bo; Cai, Wenchao; Wang, Xiaoying; Zhang, Jue; Fang, Jing

    2015-10-01

    To demonstrate the feasibility of the improved temporal resolution by using compressed sensing (CS) combined imaging sequence in dynamic contrast-enhanced MRI (DCE-MRI) of kidney, and investigate its quantitative effects on renal perfusion measurements. Ten rabbits were included in the accelerated scans with a CS-combined 3D pulse sequence. To evaluate the image quality, the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were compared between the proposed CS strategy and the conventional full sampling method. Moreover, renal perfusion was estimated by using the separable compartmental model in both CS simulation and realistic CS acquisitions. The CS method showed DCE-MRI images with improved temporal resolution and acceptable image contrast, while presenting significantly higher SNR than the fully sampled images (p<.01) at 2-, 3- and 4-X acceleration. In quantitative measurements, renal perfusion results were in good agreement with the fully sampled one (concordance correlation coefficient=0.95, 0.91, 0.88) at 2-, 3- and 4-X acceleration in CS simulation. Moreover, in realistic acquisitions, the estimated perfusion by the separable compartmental model exhibited no significant differences (p>.05) between each CS-accelerated acquisition and the full sampling method. The CS-combined 3D sequence could improve the temporal resolution for DCE-MRI in kidney while yielding diagnostically acceptable image quality, and it could provide effective measurements of renal perfusion. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Quantitative Surface Emissivity and Temperature Measurements of a Burning Solid Fuel Accompanied by Soot Formation

    NASA Technical Reports Server (NTRS)

    Piltch, Nancy D.; Pettegrew, Richard D.; Ferkul, Paul; Sacksteder, K. (Technical Monitor)

    2001-01-01

    Surface radiometry is an established technique for noncontact temperature measurement of solids. We adapt this technique to the study of solid surface combustion where the solid fuel undergoes physical and chemical changes as pyrolysis proceeds, and additionally may produce soot. The physical and chemical changes alter the fuel surface emissivity, and soot contributes to the infrared signature in the same spectral band as the signal of interest. We have developed a measurement that isolates the fuel's surface emissions in the presence of soot, and determine the surface emissivity as a function of temperature. A commercially available infrared camera images the two-dimensional surface of ashless filter paper burning in concurrent flow. The camera is sensitive in the 2 to 5 gm band, but spectrally filtered to reduce the interference from hot gas phase combustion products. Results show a strong functional dependence of emissivity on temperature, attributed to the combined effects of thermal and oxidative processes. Using the measured emissivity, radiance measurements from several burning samples were corrected for the presence of soot and for changes in emissivity, to yield quantitative surface temperature measurements. Ultimately the results will be used to develop a full-field, non-contact temperature measurement that will be used in spacebased combustion investigations.

  15. Quantitative wound healing measurement and monitoring system based on an innovative 3D imaging system

    NASA Astrophysics Data System (ADS)

    Yi, Steven; Yang, Arthur; Yin, Gongjie; Wen, James

    2011-03-01

    In this paper, we report a novel three-dimensional (3D) wound imaging system (hardware and software) under development at Technest Inc. System design is aimed to perform accurate 3D measurement and modeling of a wound and track its healing status over time. Accurate measurement and tracking of wound healing enables physicians to assess, document, improve, and individualize the treatment plan given to each wound patient. In current wound care practices, physicians often visually inspect or roughly measure the wound to evaluate the healing status. This is not an optimal practice since human vision lacks precision and consistency. In addition, quantifying slow or subtle changes through perception is very difficult. As a result, an instrument that quantifies both skin color and geometric shape variations would be particularly useful in helping clinicians to assess healing status and judge the effect of hyperemia, hematoma, local inflammation, secondary infection, and tissue necrosis. Once fully developed, our 3D imaging system will have several unique advantages over traditional methods for monitoring wound care: (a) Non-contact measurement; (b) Fast and easy to use; (c) up to 50 micron measurement accuracy; (d) 2D/3D Quantitative measurements;(e) A handheld device; and (f) Reasonable cost (< $1,000).

  16. Quantitative Aging Pattern in Mouse Urine Vapor as Measured by Gas-Liquid Chromatography

    NASA Technical Reports Server (NTRS)

    Robinson, Arthur B.; Dirren, Henri; Sheets, Alan; Miquel, Jaime; Lundgren, Paul R.

    1975-01-01

    We have discovered a quantitative aging pattern in mouse urine vapor. The diagnostic power of the pattern has been found to be high. We hope that this pattern will eventually allow quantitative estimates of physiological age and some insight into the biochemistry of aging.

  17. Measurement issues associated with quantitative molecular biology analysis of complex food matrices for the detection of food fraud.

    PubMed

    Burns, Malcolm; Wiseman, Gordon; Knight, Angus; Bramley, Peter; Foster, Lucy; Rollinson, Sophie; Damant, Andrew; Primrose, Sandy

    2016-01-07

    Following a report on a significant amount of horse DNA being detected in a beef burger product on sale to the public at a UK supermarket in early 2013, the Elliott report was published in 2014 and contained a list of recommendations for helping ensure food integrity. One of the recommendations included improving laboratory testing capacity and capability to ensure a harmonised approach for testing for food authenticity. Molecular biologists have developed exquisitely sensitive methods based on the polymerase chain reaction (PCR) or mass spectrometry for detecting the presence of particular nucleic acid or peptide/protein sequences. These methods have been shown to be specific and sensitive in terms of lower limits of applicability, but they are largely qualitative in nature. Historically, the conversion of these qualitative techniques into reliable quantitative methods has been beset with problems even when used on relatively simple sample matrices. When the methods are applied to complex sample matrices, as found in many foods, the problems are magnified resulting in a high measurement uncertainty associated with the result which may mean that the assay is not fit for purpose. However, recent advances in the technology and the understanding of molecular biology approaches have further given rise to the re-assessment of these methods for their quantitative potential. This review focuses on important issues for consideration when validating a molecular biology assay and the various factors that can impact on the measurement uncertainty of a result associated with molecular biology approaches used in detection of food fraud, with a particular focus on quantitative PCR-based and proteomics assays.

  18. Autoradiographic evidence for methamphetamine-induced striatal dopaminergic loss in mouse brain: attenuation in CuZn-superoxide dismutase transgenic mice.

    PubMed

    Hirata, H; Ladenheim, B; Carlson, E; Epstein, C; Cadet, J L

    1996-04-01

    Methamphetamine (METH) has long-lasting neurotoxic effects on the nigrostriatal dopamine (DA) system of rodents. METH-induced neurotoxicity is thought to involve release of DA in presynaptic DA terminals, which is associated with increased formation of oxygen-based free radicals. We have recently shown that METH-induced striatal DA depletion is attenuated in transgenic (Tg) mice that express the human CuZn-superoxide dismutase (SOD) enzyme. That study did not specifically address the issue of loss of DA terminals. In the present study, we have used receptor autoradiographic studies of [(125)I]RTI-121-labeled DA uptake sites to evaluate the effects of several doses of METH on striatal DA terminals of Non-Tg as well as of heterozygous and homozygous SOD-Tg mice. In Non-Tg mice, METH caused decreases in striatal DA uptake sites in a dose-dependent fashion. The loss of DA terminals was more prominent in the lateral region than in the medial subdivisions of the striatum. In SOD-Tg mice, the loss of DA terminals caused by METH was attenuated in a gene dosage-dependent fashion, with the homozygous mice showing the greatest protection. Female mice were somewhat more resistant than male mice against these deleterious effects of METH. These results provide further evidence for a role of superoxide radicals in the long-term effects of METH. They also suggest the notion of a gender-specific handling of oxidative stress.

  19. A quantitative framework for assessing ecological resilience

    EPA Science Inventory

    Quantitative approaches to measure and assess resilience are needed to bridge gaps between science, policy, and management. In this paper, we suggest a quantitative framework for assessing ecological resilience. Ecological resilience as an emergent ecosystem phenomenon can be de...

  20. Do Quantitative Measures of Research Productivity Correlate with Academic Rank in Oral and Maxillofacial Surgery?

    PubMed

    Susarla, Srinivas M; Dodson, Thomas B; Lopez, Joseph; Swanson, Edward W; Calotta, Nicholas; Peacock, Zachary S

    2015-08-01

    Academic promotion is linked to research productivity. The purpose of this study was to assess the correlation between quantitative measures of academic productivity and academic rank among academic oral and maxillofacial surgeons. This was a cross-sectional study of full-time academic oral and maxillofacial surgeons in the United States. The predictor variables were categorized as demographic (gender, medical degree, research doctorate, other advanced degree) and quantitative measures of academic productivity (total number of publications, total number of citations, maximum number of citations for a single article, I-10 index [number of publications with ≥ 10 citations], and h-index [number of publications h with ≥ h citations each]). The outcome variable was current academic rank (instructor, assistant professor, associate professor, professor, or endowed professor). Descriptive, bivariate, and multiple regression statistics were computed to evaluate associations between the predictors and academic rank. Receiver-operator characteristic curves were computed to identify thresholds for academic promotion. The sample consisted of 324 academic oral and maxillofacial surgeons, of whom 11.7% were female, 40% had medical degrees, and 8% had research doctorates. The h-index was the most strongly correlated with academic rank (ρ = 0.62, p < 0.001). H-indexes of ≥ 4, ≥ 8, and ≥ 13 were identified as thresholds for promotion to associate professor, professor, and endowed professor, respectively (p < 0.001). This study found that the h-index was strongly correlated with academic rank among oral and maxillofacial surgery faculty members and thus suggests that promotions committees should consider using the h-index as an additional method to assess research activity.

  1. Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin Mingde; Marshall, Craig T.; Qi, Yi

    Purpose: The use of preclinical rodent models of disease continues to grow because these models help elucidate pathogenic mechanisms and provide robust test beds for drug development. Among the major anatomic and physiologic indicators of disease progression and genetic or drug modification of responses are measurements of blood vessel caliber and flow. Moreover, cardiopulmonary blood flow is a critical indicator of gas exchange. Current methods of measuring cardiopulmonary blood flow suffer from some or all of the following limitations--they produce relative values, are limited to global measurements, do not provide vasculature visualization, are not able to measure acute changes, aremore » invasive, or require euthanasia. Methods: In this study, high-spatial and high-temporal resolution x-ray digital subtraction angiography (DSA) was used to obtain vasculature visualization, quantitative blood flow in absolute metrics (ml/min instead of arbitrary units or velocity), and relative blood volume dynamics from discrete regions of interest on a pixel-by-pixel basis (100x100 {mu}m{sup 2}). Results: A series of calibrations linked the DSA flow measurements to standard physiological measurement using thermodilution and Fick's method for cardiac output (CO), which in eight anesthetized Fischer-344 rats was found to be 37.0{+-}5.1 ml/min. Phantom experiments were conducted to calibrate the radiographic density to vessel thickness, allowing a link of DSA cardiac output measurements to cardiopulmonary blood flow measurements in discrete regions of interest. The scaling factor linking relative DSA cardiac output measurements to the Fick's absolute measurements was found to be 18.90xCO{sub DSA}=CO{sub Fick}. Conclusions: This calibrated DSA approach allows repeated simultaneous visualization of vasculature and measurement of blood flow dynamics on a regional level in the living rat.« less

  2. Quantitative Species Measurements in Microgravity Combustion Flames using Near-Infrared Diode Lasers

    NASA Technical Reports Server (NTRS)

    Silver, Joel A.

    1999-01-01

    Understanding the physical phenomena controlling the ignition and spread of flames in microgravity has importance for space safety as well as for characterizing dynamical and chemical combustion processes which are normally masked by buoyancy and other gravity-related effects. Unfortunately, combustion is highly complicated by fluid mechanical and chemical kinetic processes, requiring the use of numerical modeling to compare with carefully designed experiments. More sophisticated diagnostic methods are needed to provide the kind of quantitative data necessary to characterize the properties of microgravity combustion as well as provide accurate feedback to improve the predictive capabilities of the models. Diode lasers are a natural choice for use under the severe conditions of low gravity experiments. Reliable, simple solid state operation at low power satisfies the operational restrictions imposed by drop towers, aircraft and space-based studies. Modulation wavelength absorption spectroscopy (WMS) provides a means to make highly sensitive and quantitative measurements of local gas concentration and, in certain cases, temperature. With near-infrared diode lasers, detection of virtually all major combustion species with extremely rapid response time is possible in an inexpensive package. Advancements in near-infrared diode laser fabrication technology and concurrent development of optical fibers for these lasers led to their use in drop towers. Since near-infrared absorption line strengths for overtone and combination vibrational transitions are weaker than the mid-infrared fundamental bands, WMS techniques are applied to increase detection sensitivity and allow measurement of the major combustion gases. In the first microgravity species measurement, Silver et al. mounted a fiber-coupled laser at the top of the NASA 2.2-sec drop tower and piped the light through a single-mode fiber to the drop rig. A fiber splitter divided the light into eight channels that directed

  3. Proof of the quantitative potential of immunofluorescence by mass spectrometry.

    PubMed

    Toki, Maria I; Cecchi, Fabiola; Hembrough, Todd; Syrigos, Konstantinos N; Rimm, David L

    2017-03-01

    Protein expression in formalin-fixed, paraffin-embedded patient tissue is routinely measured by Immunohistochemistry (IHC). However, IHC has been shown to be subject to variability in sensitivity, specificity and reproducibility, and is generally, at best, considered semi-quantitative. Mass spectrometry (MS) is considered by many to be the criterion standard for protein measurement, offering high sensitivity, specificity, and objective molecular quantification. Here, we seek to show that quantitative immunofluorescence (QIF) with standardization can achieve quantitative results comparable to MS. Epidermal growth factor receptor (EGFR) was measured by quantitative immunofluorescence in 15 cell lines with a wide range of EGFR expression, using different primary antibody concentrations, including the optimal signal-to-noise concentration after quantitative titration. QIF target measurement was then compared to the absolute EGFR concentration measured by Liquid Tissue-selected reaction monitoring mass spectrometry. The best agreement between the two assays was found when the EGFR primary antibody was used at the optimal signal-to-noise concentration, revealing a strong linear regression (R 2 =0.88). This demonstrates that quantitative optimization of titration by calculation of signal-to-noise ratio allows QIF to be standardized to MS and can therefore be used to assess absolute protein concentration in a linear and reproducible manner.

  4. A quantitative measure of the electrical activity of human rod photoreceptors using electroretinography.

    PubMed

    Hood, D C; Birch, D G

    1990-10-01

    An electrical potential recorded from the cornea, the a-wave of the ERG, is evaluated as a measure of human photoreceptor activity by comparing its behavior to a model derived from in vitro recordings from rod photoreceptors. The leading edge of the ERG exhibits both the linear and nonlinear behavior predicted by this model. The capability for recording the electrical activity of human photoreceptors in vivo opens new avenues for assessing normal and abnormal receptor activity in humans. Furthermore, the quantitative model of the receptor response can be used to isolate the inner retinal contribution, Granit's PII, to the gross ERG. Based on this analysis, the practice of using the trough-to-peak amplitude of the b-wave as a proxy for the amplitude of the inner nuclear layer activity is evaluated.

  5. Comprehensive comparison of self-administered questionnaires for measuring quantitative autistic traits in adults.

    PubMed

    Nishiyama, Takeshi; Suzuki, Masako; Adachi, Katsunori; Sumi, Satoshi; Okada, Kensuke; Kishino, Hirohisa; Sakai, Saeko; Kamio, Yoko; Kojima, Masayo; Suzuki, Sadao; Kanne, Stephen M

    2014-05-01

    We comprehensively compared all available questionnaires for measuring quantitative autistic traits (QATs) in terms of reliability and construct validity in 3,147 non-clinical and 60 clinical subjects with normal intelligence. We examined four full-length forms, the Subthreshold Autism Trait Questionnaire (SATQ), the Broader Autism Phenotype Questionnaire, the Social Responsiveness Scale2-Adult Self report (SRS2-AS), and the Autism-Spectrum Quotient (AQ). The SRS2-AS and the AQ each had several short forms that we also examined, bringing the total to 11 forms. Though all QAT questionnaires showed acceptable levels of test-retest reliability, the AQ and SRS2-AS, including their short forms, exhibited poor internal consistency and discriminant validity, respectively. The SATQ excelled in terms of classical test theory and due to its short length.

  6. Quantitative secondary electron detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agrawal, Jyoti; Joy, David C.; Nayak, Subuhadarshi

    Quantitative Secondary Electron Detection (QSED) using the array of solid state devices (SSD) based electron-counters enable critical dimension metrology measurements in materials such as semiconductors, nanomaterials, and biological samples (FIG. 3). Methods and devices effect a quantitative detection of secondary electrons with the array of solid state detectors comprising a number of solid state detectors. An array senses the number of secondary electrons with a plurality of solid state detectors, counting the number of secondary electrons with a time to digital converter circuit in counter mode.

  7. Diagnostic accuracy of stress perfusion CMR in comparison with quantitative coronary angiography: fully quantitative, semiquantitative, and qualitative assessment.

    PubMed

    Mordini, Federico E; Haddad, Tariq; Hsu, Li-Yueh; Kellman, Peter; Lowrey, Tracy B; Aletras, Anthony H; Bandettini, W Patricia; Arai, Andrew E

    2014-01-01

    This study's primary objective was to determine the sensitivity, specificity, and accuracy of fully quantitative stress perfusion cardiac magnetic resonance (CMR) versus a reference standard of quantitative coronary angiography. We hypothesized that fully quantitative analysis of stress perfusion CMR would have high diagnostic accuracy for identifying significant coronary artery stenosis and exceed the accuracy of semiquantitative measures of perfusion and qualitative interpretation. Relatively few studies apply fully quantitative CMR perfusion measures to patients with coronary disease and comparisons to semiquantitative and qualitative methods are limited. Dual bolus dipyridamole stress perfusion CMR exams were performed in 67 patients with clinical indications for assessment of myocardial ischemia. Stress perfusion images alone were analyzed with a fully quantitative perfusion (QP) method and 3 semiquantitative methods including contrast enhancement ratio, upslope index, and upslope integral. Comprehensive exams (cine imaging, stress/rest perfusion, late gadolinium enhancement) were analyzed qualitatively with 2 methods including the Duke algorithm and standard clinical interpretation. A 70% or greater stenosis by quantitative coronary angiography was considered abnormal. The optimum diagnostic threshold for QP determined by receiver-operating characteristic curve occurred when endocardial flow decreased to <50% of mean epicardial flow, which yielded a sensitivity of 87% and specificity of 93%. The area under the curve for QP was 92%, which was superior to semiquantitative methods: contrast enhancement ratio: 78%; upslope index: 82%; and upslope integral: 75% (p = 0.011, p = 0.019, p = 0.004 vs. QP, respectively). Area under the curve for QP was also superior to qualitative methods: Duke algorithm: 70%; and clinical interpretation: 78% (p < 0.001 and p < 0.001 vs. QP, respectively). Fully quantitative stress perfusion CMR has high diagnostic accuracy for

  8. Advances in Surface Plasmon Resonance Imaging enable quantitative measurement of laterally heterogeneous coatings of nanoscale thickness

    NASA Astrophysics Data System (ADS)

    Raegen, Adam; Reiter, Kyle; Clarke, Anthony; Lipkowski, Jacek; Dutcher, John

    2013-03-01

    The Surface Plasmon Resonance (SPR) phenomenon is routinely exploited to qualitatively probe changes to the optical properties of nanoscale coatings on thin metallic surfaces, for use in probes and sensors. Unfortunately, extracting truly quantitative information is usually limited to a select few cases - uniform absorption/desorption of small biomolecules and films, in which a continuous ``slab'' model is a good approximation. We present advancements in the SPR technique that expand the number of cases for which the technique can provide meaningful results. Use of a custom, angle-scanning SPR imaging system, together with a refined data analysis method, allow for quantitative kinetic measurements of laterally heterogeneous systems. We first demonstrate the directionally heterogeneous nature of the SPR phenomenon using a directionally ordered sample, then show how this allows for the calculation of the average coverage of a heterogeneous sample. Finally, the degradation of cellulose microfibrils and bundles of microfibrils due to the action of cellulolytic enzymes will be presented as an excellent example of the capabilities of the SPR imaging system.

  9. Quantitative head ultrasound measurements to determine thresholds for preterm neonates requiring interventional therapies following intraventricular hemorrhage

    NASA Astrophysics Data System (ADS)

    Kishimoto, Jessica; Fenster, Aaron; Salehi, Fateme; Romano, Walter; Lee, David S. C.; de Ribaupierre, Sandrine

    2016-04-01

    Dilation of the cerebral ventricles is a common condition in preterm neonates with intraventricular hemorrhage (IVH). This post hemorrhagic ventricle dilation (PHVD) can lead to lifelong neurological impairment through ischemic injury due to increased intracranial pressure and without treatment, can lead to death. Clinically, 2D ultrasound (US) through the fontanelles ('soft spots') of the patients are serially acquired to monitor the progression of the ventricle dilation. These images are used to determine when interventional therapies such as needle aspiration of the built up cerebrospinal fluid (CSF) ('ventricle tap', VT) might be indicated for a patient; however, quantitative measurements of the growth of the ventricles are often not performed. There is no consensus on when a neonate with PHVD should have an intervention and often interventions are performed after the potential for brain damage is quite high. Previously we have developed and validated a 3D US system to monitor the progression of ventricle volumes (VV) in IVH patients. We will describe the potential utility of quantitative 2D and 3D US to monitor and manage PHVD in neonates. Specifically, we will look to determine image-based measurement thresholds for patients who will require VT in comparison to patients with PHVD who resolve without intervention. Additionally, since many patients who have an initial VT will require subsequent interventions, we look at the potential for US to determine which PHVD patients will require additional VT after the initial one has been performed.

  10. Quantitative thickness measurement of polarity-inverted piezoelectric thin-film layer by scanning nonlinear dielectric microscopy

    NASA Astrophysics Data System (ADS)

    Odagawa, Hiroyuki; Terada, Koshiro; Tanaka, Yohei; Nishikawa, Hiroaki; Yanagitani, Takahiko; Cho, Yasuo

    2017-10-01

    A quantitative measurement method for a polarity-inverted layer in ferroelectric or piezoelectric thin film is proposed. It is performed nondestructively by scanning nonlinear dielectric microscopy (SNDM). In SNDM, linear and nonlinear dielectric constants are measured using a probe that converts the variation of capacitance related to these constants into the variation of electrical oscillation frequency. In this paper, we describe a principle for determining the layer thickness and some calculation results of the output signal, which are related to the radius of the probe tip and the thickness of the inverted layer. Moreover, we derive an equation that represents the relationship between the output signal and the oscillation frequency of the probe and explain how to determine the thickness from the measured frequency. Experimental results in Sc-doped AlN piezoelectric thin films that have a polarity-inverted layer with a thickness of 1.5 µm fabricated by radio frequency magnetron sputtering showed a fairly good value of 1.38 µm for the thickness of the polarity-inverted layer.

  11. Correlation between quantitative PCR and Culture-Based methods for measuring Enterococcus spp. over various temporal scales at three California marine beaches

    EPA Science Inventory

    Several studies have examined how fecal indicator bacteria (FIB) measurements compare between quantitative polymerase chain reaction (QPCR) and the culture methods it is intended to replace. Here we extend those studies by examining the stability of that relationship within a be...

  12. Association between right ventricular dysfunction and restrictive lung disease in childhood cancer survivors as measured by quantitative echocardiography.

    PubMed

    Patel, Amee; Weismann, Constance; Weiss, Pnina; Russell, Kerry; Bazzy-Asaad, Alia; Kadan-Lottick, Nina S

    2014-11-01

    Restrictive lung disease is a complication in childhood cancer survivors who received lung-toxic chemotherapy and/or thoracic radiation. Left ventricular dysfunction is documented in these survivors, but less is known about right ventricular (RV) function. Quantitative echocardiography may help detect subclinical RV dysfunction. The aim of this study was to assess RV function quantitatively in childhood cancer survivors after lung-toxic therapy. We identified records of 33 childhood cancer survivors who (1) were treated with lung-toxic therapy and/or radiation, (2) were cancer-free for ≥ one year after therapy, and (3) had pulmonary function tests and echocardiograms from their most recent follow-up visit. Participants' mean age was 11.6 ± 4.5 years at cancer diagnosis and 23 ± 8.6 years at evaluation. The most common diagnosis was lymphoma/leukemia (n = 27). Twenty-nine subjects had anthracycline exposure. Eleven of the 33 subjects demonstrated restrictive pulmonary impairment (total lung capacity 3.69 ± 1.5 L [69.3 ± 22.4% predicted]). Among quantitative measures of RV function, isovolumetric acceleration (IVA), a measure of contractility, was significantly lower in the group with restrictive lung disease (2.42 ± 0.56 vs. 1.83 ± 0.78 m/sec(2); P < 0.05). There was a trend towards lower tissue Doppler derived S' and tricuspid annular plane systolic excursion in the group with restrictive lung disease. Subjects with restrictive lung disease were found to have ≥ 2 abnormal parameters (P < 0.01). IVA may detect early RV dysfunction in childhood cancer survivors with restrictive lung disease. Our findings require confirmation in a larger study population and validation by cardiac MRI. © 2014 Wiley Periodicals, Inc.

  13. Quantitation of Fine Displacement in Echography

    NASA Astrophysics Data System (ADS)

    Masuda, Kohji; Ishihara, Ken; Yoshii, Ken; Furukawa, Toshiyuki; Kumagai, Sadatoshi; Maeda, Hajime; Kodama, Shinzo

    1993-05-01

    A High-speed Digital Subtraction Echography was developed to visualize the fine displacement of human internal organs. This method indicates differences in position through time series images of high-frame-rate echography. Fine displacement less than ultrasonic wavelength can be observed. This method, however, lacks the ability to quantitatively measure displacement length. The subtraction between two successive images was affected by displacement direction in spite of the displacement length being the same. To solve this problem, convolution of an echogram with Gaussian distribution was used. To express displacement length as brightness quantitatively, normalization using a brightness gradient was applied. The quantitation algorithm was applied to successive B-mode images. Compared to the simply subtracted images, quantitated images express more precisely the motion of organs. Expansion of the carotid artery and fine motion of ventricular walls can be visualized more easily. Displacement length can be quantitated with wavelength. Under more static conditions, this system quantitates displacement length that is much less than wavelength.

  14. 5-Aminolevulinic acid-induced protoporphyrin IX fluorescence in meningioma: qualitative and quantitative measurements in vivo.

    PubMed

    Valdes, Pablo A; Bekelis, Kimon; Harris, Brent T; Wilson, Brian C; Leblond, Frederic; Kim, Anthony; Simmons, Nathan E; Erkmen, Kadir; Paulsen, Keith D; Roberts, David W

    2014-03-01

    The use of 5-aminolevulinic acid (ALA)-induced protoporphyrin IX (PpIX) fluorescence has shown promise as a surgical adjunct for maximizing the extent of surgical resection in gliomas. To date, the clinical utility of 5-ALA in meningiomas is not fully understood, with most descriptive studies using qualitative approaches to 5-ALA-PpIX. To assess the diagnostic performance of 5-ALA-PpIX fluorescence during surgical resection of meningioma. ALA was administered to 15 patients with meningioma undergoing PpIX fluorescence-guided surgery at our institution. At various points during the procedure, the surgeon performed qualitative, visual assessments of fluorescence by using the surgical microscope, followed by a quantitative fluorescence measurement by using an intraoperative probe. Specimens were collected at each point for subsequent neuropathological analysis. Clustered data analysis of variance was used to ascertain a difference between groups, and receiver operating characteristic analyses were performed to assess diagnostic capabilities. Red-pink fluorescence was observed in 80% (12/15) of patients, with visible fluorescence generally demonstrating a strong, homogenous character. Quantitative fluorescence measured diagnostically significant PpIX concentrations (cPpIx) in both visibly and nonvisibly fluorescent tissues, with significantly higher cPpIx in both visibly fluorescent (P < .001) and tumor tissue (P = .002). Receiver operating characteristic analyses also showed diagnostic accuracies up to 90% for differentiating tumor from normal dura. ALA-induced PpIX fluorescence guidance is a potential and promising adjunct in accurately detecting neoplastic tissue during meningioma resective surgery. These results suggest a broader reach for PpIX as a biomarker for meningiomas than was previously noted in the literature.

  15. 5-Aminolevulinic Acid-Induced Protoporphyrin IX Fluorescence in Meningioma: Qualitative and Quantitative Measurements In Vivo

    PubMed Central

    Valdes, Pablo A.; Bekelis, Kimon; Harris, Brent T.; Wilson, Brian C.; Leblond, Frederic; Kim, Anthony; Simmons, Nathan E.; Erkmen, Kadir; Paulsen, Keith D.; Roberts, David W.

    2014-01-01

    BACKGROUND The use of 5-aminolevulinic acid (ALA)-induced protoporphyrin IX (PpIX) fluorescence has shown promise as a surgical adjunct for maximizing the extent of surgical resection in gliomas. To date, the clinical utility of 5-ALA in meningiomas is not fully understood, with most descriptive studies using qualitative approaches to 5-ALA-PpIX. OBJECTIVE To assess the diagnostic performance of 5-ALA-PpIX fluorescence during surgical resection of meningioma. METHODS ALA was administered to 15 patients with meningioma undergoing PpIX fluorescence-guided surgery at our institution. At various points during the procedure, the surgeon performed qualitative, visual assessments of fluorescence by using the surgical microscope, followed by a quantitative fluorescence measurement by using an intra-operative probe. Specimens were collected at each point for subsequent neuropathological analysis. Clustered data analysis of variance was used to ascertain a difference between groups, and receiver operating characteristic analyses were performed to assess diagnostic capabilities. RESULTS Red-pink fluorescence was observed in 80% (12/15) of patients, with visible fluorescence generally demonstrating a strong, homogenous character. Quantitative fluorescence measured diagnostically significant PpIX concentrations (CPpIx) in both visibly and nonvisibly fluorescent tissues, with significantly higher CPpIx in both visibly fluorescent (P < .001) and tumor tissue (P = .002). Receiver operating characteristic analyses also showed diagnostic accuracies up to 90% for differentiating tumor from normal dura. CONCLUSION ALA-induced PpIX fluorescence guidance is a potential and promising adjunct in accurately detecting neoplastic tissue during meningioma resective surgery. These results suggest a broader reach for PpIX as a biomarker for meningiomas than was previously noted in the literature. PMID:23887194

  16. Quantitative measurement of the near-field enhancement of nanostructures by two-photon polymerization.

    PubMed

    Geldhauser, Tobias; Kolloch, Andreas; Murazawa, Naoki; Ueno, Kosei; Boneberg, Johannes; Leiderer, Paul; Scheer, Elke; Misawa, Hiroaki

    2012-06-19

    The quantitative determination of the strength of the near-field enhancement in and around nanostructures is essential for optimizing and using these structures for applications. We combine the gaussian intensity distribution of a laser profile and two-photon-polymerization of SU-8 to a suitable tool for the quantitative experimental measurement of the near-field enhancement of a nanostructure. Our results give a feedback to the results obtained by finite-difference time-domain (FDTD) simulations. The structures under investigation are gold nanotriangles on a glass substrate with 85 nm side length and a thickness of 40 nm. We compare the threshold fluence for polymerization for areas of the gaussian intensity profile with and without the near-field enhancement of the nanostructures. The experimentally obtained value of the near-field intensity enhancement is 600 ± 140, independent of the laser power, irradiation time, and spot size. The FDTD simulation shows a pointlike maximum of 2600 at the tip. In a more extended area with an approximate size close to the smallest polymerized structure of 25 nm in diameter, we find a value between 800 and 600. Using our novel approach, we determine the threshold fluence for polymerization of the commercially available photopolymerizable resin SU-8 by a femtosecond laser working at a wavelength of 795 nm and a repetition rate of 82 MHz to be 0.25 J/cm(2) almost independent of the irradiation time and the laser power used. This finding is important for future applications of the method because it enables one to use varying laser systems.

  17. Second harmonic generation quantitative measurements on collagen fibrils through correlation to electron microscopy

    NASA Astrophysics Data System (ADS)

    Bancelin, S.; Aimé, C.; Gusachenko, I.; Kowalczuk, L.; Latour, G.; Coradin, T.; Schanne-Klein, M.-C.

    2015-03-01

    Type I collagen is a major structural protein in mammals that shows highly structured macromolecular organizations specific to each tissue. This biopolymer is synthesized as triple helices, which self-assemble into fibrils (Ø =10-300 nm) and further form various 3D organization. In recent years, Second Harmonic Generation (SHG) microscopy has emerged as a powerful technique to probe in situ the fibrillar collagenous network within tissues. However, this optical technique cannot resolve most of the fibrils and is a coherent process, which has impeded quantitative measurements of the fibril diameter so far. In this study, we correlated SHG microscopy with Transmission Electron Microscopy to determine the sensitivity of SHG microscopy and to calibrate SHG signals as a function of the fibril diameter in reconstructed collagen gels. To that end, we synthetized isolated fibrils with various diameters and successfully imaged the very same fibrils with both techniques, down to 30 nm diameter. We observed that SHG signals scaled as the fourth power of the fibril diameter, as expected from analytical and numerical calculations. This calibration was then applied to diabetic rat cornea in which we successfully recovered the diameter of hyperglycemia-induced fibrils in the Descemet's membrane without having to resolve them. Finally we derived the first hyperpolarizability from a single collagen triple helix which validates the bottom-up approach used to calculate the non-linear response at the fibrillar scale and denotes a parallel alignment of triple helices within the fibrils. These results represent a major step towards quantitative SHG imaging of nm-sized collagen fibrils.

  18. Qualitative and quantitative changes in exoskeletal proteins synthesized throughout the molt cycle of the Bermuda land crab

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stringfellow, L.A.; Skinner, D.M.

    1987-05-01

    During the premolt period in Crustacea, a single layer of epidermal cells that underlies the exoskeleton is thought to be responsible for the degradation of the old exoskeleton and synthesis of a new one. In order to identify molt-specific proteins and their temporal appearance, they cultured epidermis and associated integumentary tissue from the gill chambers of crab in vitro in the presence of one of three radiolabeled amino acids. Autoradiographs of (/sup 35/S)Met-labeled tissues indicate a low level of synthesis in epidermal cells of intermolt animals; synthesis increases during premolt and stage B of postmolt. Label is also found inmore » the innermost layer of the old exoskeleton while it is being degraded and in new exoskeletal layers during their synthesis. Fluorographs of gels of integumentary proteins show marked quantitative changes in 44 and 56 kD proteins late in premolt. Qualitative changes include synthesis of 46 and 48 kD proteins during late premolt and three proteins (all of approx. 170 kD) detectable only in postmolt. Solubilized gel slices of (/sup 3/H)Leu-labeled proteins indicate maximum synthesis at an earlier premolt stage than seen in Met-labeled proteins. Other proteins of 20, 24, 29, 32, and 96 kD are synthesized in a stage-dependent manner while (/sup 3/H)Tyr labels small proteins that appear only in late premolt.« less

  19. Laser-induced breakdown spectroscopy (LIBS) to measure quantitatively soil carbon with emphasis on soil organic carbon. A review.

    PubMed

    Senesi, Giorgio S; Senesi, Nicola

    2016-09-28

    Soil organic carbon (OC) measurement is a crucial factor for quantifying soil C pools and inventories and monitoring the inherent temporal and spatial heterogeneity and changes of soil OC content. These are relevant issues in addressing sustainable management of terrestrial OC aiming to enhance C sequestration in soil, thus mitigating the impact of increasing CO2 concentration in the atmosphere and related effects on global climate change. Nowadays, dry combustion by an elemental analyzer or wet combustion by dichromate oxidation of the soil sample are the most recommended and commonly used methods for quantitative soil OC determination. However, the unanimously recognized uncertainties and limitations of these classical laboursome methods have prompted research efforts focusing on the development and application of more advanced and appealing techniques and methods for the measurement of soil OC in the laboratory and possibly in situ in the field. Among these laser-induced breakdown spectroscopy (LIBS) has raised the highest interest for its unique advantages. After an introduction and a highlight of the LIBS basic principles, instrumentation, methodologies and supporting chemometric methods, the main body of this review provides an historical and critical overview of the developments and results obtained up-to-now by the application of LIBS to the quantitative measurement of soil C and especially OC content. A brief critical summary of LIBS advantages and limitations/drawbacks including some final remarks and future perspectives concludes this review. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Quantitative measurement of MLC leaf displacements using an electronic portal image device

    NASA Astrophysics Data System (ADS)

    Yang, Yong; Xing, Lei

    2004-04-01

    The success of an IMRT treatment relies on the positioning accuracy of the MLC (multileaf collimator) leaves for both step-and-shoot and dynamic deliveries. In practice, however, there exists no effective and quantitative means for routine MLC QA and this has become one of the bottleneck problems in IMRT implementation. In this work we present an electronic portal image device (EPID) based method for fast and accurate measurement of MLC leaf positions at arbitrary locations within the 40 cm × 40 cm radiation field. The new technique utilizes the fact that the integral signal in a small region of interest (ROI) is a sensitive and reliable indicator of the leaf displacement. In this approach, the integral signal at a ROI was expressed as a weighted sum of the contributions from the displacements of the leaf above the point and the adjacent leaves. The weighting factors or linear coefficients of the system equations were determined by fitting the integral signal data for a group of pre-designed MLC leaf sequences to the known leaf displacements that were intentionally introduced during the creation of the leaf sequences. Once the calibration is done, the system can be used for routine MLC leaf positioning QA to detect possible leaf errors. A series of tests was carried out to examine the functionality and accuracy of the technique. Our results show that the proposed technique is potentially superior to the conventional edge-detecting approach in two aspects: (i) it deals with the problem in a systematic approach and allows us to take into account the influence of the adjacent MLC leaves effectively; and (ii) it may improve the signal-to-noise ratio and is thus capable of quantitatively measuring extremely small leaf positional displacements. Our results indicate that the technique can detect a leaf positional error as small as 0.1 mm at an arbitrary point within the field in the absence of EPID set-up error and 0.3 mm when the uncertainty is considered. Given its

  1. Measurements of the quantitative lateral analytical resolution at evaporated aluminium and silver layers with the JEOL JXA-8530F FEG-EPMA

    NASA Astrophysics Data System (ADS)

    Berger, D.; Nissen, J.

    2018-01-01

    The studies in this paper are part of systematic investigations of the lateral analytical resolution of the field emission electron microprobe JEOL JXA-8530F. Hereby, the quantitative lateral resolution, which is achieved in practise, is in the focus of interest. The approach is to determine the minimum thickness of a metallic layer for which an accurate quantitative element analysis in cross-section is still possible. Previous measurements were accomplished at sputtered gold (Z = 79) layers, where a lateral resolution in the range of 140 to 170 nm was achieved at suitable parameters of the microprobe. To study the Z-dependence of the lateral resolution, now aluminium (Z = 13) resp. silver (Z = 47) layers with different thicknesses were generated by evaporation and prepared in cross-section subsequently by use of a focussed Ga-ion beam (FIB). Each layer was analysed quantitatively with different electron energies. The thinnest layer which can be resolved specifies the best lateral resolution. These measured values were compared on the one hand with Monte Carlo simulations and on the other hand with predictions from formulas from the literature. The measurements fit well to the simulated and calculated values, except the ones at the lowest primary electron energies with an overvoltage below ˜ 2. The reason for this discrepancy is not clear yet and has to be clarified by further investigations. The results apply for any microanalyser - even with energy-dispersive X-ray spectrometry (EDS) detection - if the probe diameters, which might deviate from those of the JEOL JXA-8530F, at suitable analysing parameters are considered.

  2. Quantitative measurement of natural radioactivity in some roofing tile materials used in upper Egypt.

    PubMed

    Uosif, M A M

    2013-09-01

    The quantitative measurement of radionuclides ((226)Ra, (232)Th and (40)K) in some roofing tile materials (granite, alabaster, marble, traditional and advanced ceramic) used in Upper Egypt is presented in this paper. Measurements were done by using gamma spectrometry (NaI (Tl) 3" × 3"). The values of concentration of natural radionuclides were in the following ranges: 12-78.9 Bq kg(-1) for (226)Ra, 8.4-113.1 Bq kg(-1) for (232)Th and 94.9-509 Bq kg(-1)for (40)K. The activity concentration index (I), the specific dose rates indoors ( ) and the annual effective dose (DE) due to gamma radiation were calculated for each investigated sample. The lowest value of I is 0.19 for alabaster, while the highest one is 0.88 for traditional and advanced ceramic. The ranges of DE are between 0.03 and 0.13 mSv, it is below the maximal permitted values, so that the examined materials could be used as roofing tiles in the construction of new buildings.

  3. Development of Naphthalene PLIF for Making Quantitative Measurements of Ablation Products Transport in Supersonic Flows

    NASA Astrophysics Data System (ADS)

    Combs, Christopher; Clemens, Noel

    2014-11-01

    Ablation is a multi-physics process involving heat and mass transfer and codes aiming to predict ablation are in need of experimental data pertaining to the turbulent transport of ablation products for validation. Low-temperature sublimating ablators such as naphthalene can be used to create a limited physics problem and simulate ablation at relatively low temperature conditions. At The University of Texas at Austin, a technique is being developed that uses planar laser-induced fluorescence (PLIF) of naphthalene to visualize the transport of ablation products in a supersonic flow. In the current work, naphthalene PLIF will be used to make quantitative measurements of the concentration of ablation products in a Mach 5 turbulent boundary layer. For this technique to be used for quantitative research in supersonic wind tunnel facilities, the fluorescence properties of naphthalene must first be investigated over a wide range of state conditions and excitation wavelengths. The resulting calibration of naphthalene fluorescence will be applied to the PLIF images of ablation from a boundary layer plug, yielding 2-D fields of naphthalene mole fraction. These images may help provide data necessary to validate computational models of ablative thermal protection systems for reentry vehicles. Work supported by NASA Space Technology Research Fellowship Program under grant NNX11AN55H.

  4. Quantitative Measurement of Integrated Band Intensities of Isoprene and Formaldehyde

    NASA Astrophysics Data System (ADS)

    Brauer, Carolyn S.; Johnson, Timothy J.; Blake, Thomas A.; Sams, Robert L.

    2013-06-01

    The OH-initiated oxidation of isoprene, which is one of the primary volatile organic compounds produced by vegetation, is a major source of atmospheric formaldehyde and other oxygenated organics. Both molecules are also known products of biomass burning. Absorption coefficients and integrated band intensities for isoprene and formaldehyde are reported in the 600 - 6500 cm^{-1} region. The pressure broadened (1 atmosphere N_2) spectra were recorded at 278, 298 and 323 K in a 19.96 cm path length cell at 0.112 cm^{-1} resolution, using a Bruker 66V FTIR. Composite spectra are composed of a minimum of seven pressures at each temperature for both molecules. These data are part of the PNNL Spectral Database, which contains quantitative spectra of over 600 molecules. These quantitative spectra facilitate atmospheric monitoring for both remote and in situ sensing and such applications will be discussed. Timothy J. Johnson, Luisa T. M. Profeta, Robert L. Sams, David W. T. Griffith, Robert L. Yokelson Vibrational Spectroscopy {53}(1);97-102 (2010).

  5. Towards quantitative assessment of calciphylaxis

    NASA Astrophysics Data System (ADS)

    Deserno, Thomas M.; Sárándi, István.; Jose, Abin; Haak, Daniel; Jonas, Stephan; Specht, Paula; Brandenburg, Vincent

    2014-03-01

    Calciphylaxis is a rare disease that has devastating conditions associated with high morbidity and mortality. Calciphylaxis is characterized by systemic medial calcification of the arteries yielding necrotic skin ulcerations. In this paper, we aim at supporting the installation of multi-center registries for calciphylaxis, which includes a photographic documentation of skin necrosis. However, photographs acquired in different centers under different conditions using different equipment and photographers cannot be compared quantitatively. For normalization, we use a simple color pad that is placed into the field of view, segmented from the image, and its color fields are analyzed. In total, 24 colors are printed on that scale. A least-squares approach is used to determine the affine color transform. Furthermore, the card allows scale normalization. We provide a case study for qualitative assessment. In addition, the method is evaluated quantitatively using 10 images of two sets of different captures of the same necrosis. The variability of quantitative measurements based on free hand photography is assessed regarding geometric and color distortions before and after our simple calibration procedure. Using automated image processing, the standard deviation of measurements is significantly reduced. The coefficients of variations yield 5-20% and 2-10% for geometry and color, respectively. Hence, quantitative assessment of calciphylaxis becomes practicable and will impact a better understanding of this rare but fatal disease.

  6. Measuring dynamic membrane fluctuations in cell membrane using quantitative phase imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Lee, SangYun; Kim, Kyoohyun; Park, YongKeun

    2017-02-01

    There is a strong correlation between the dynamic membrane fluctuations and the biomechanical properties of living cells. The dynamic membrane fluctuation consists of submicron displacements, and can be altered by changing the cells' pathophysiological conditions. These results have significant relevance to the understanding of RBC biophysics and pathology, as follows. RBCs must withstand large mechanical deformations during repeated passages through the microvasculature and the fenestrated walls of the splenic sinusoids. This essential ability is diminished with senescence, resulting in physiological destruction of the aging RBCs. Pathological destruction of the red cells, however, occurs in cells affected by a host of diseases such as spherocytosis, malaria, and Sickle cell disease, as RBCs depart from their normal discoid shape and lose their deformability. Therefore, quantifying the RBC deformability insight into a variety of problems regarding the interplay of cell structure, dynamics, and function. Furthermore, the ability to monitor mechanical properties of RBCs is of vital interest in monitoring disease progression or response to treatment as molecular and pharmaceutical approaches for treatment of chronic diseases. Here, we present the measurements of dynamic membrane fluctuations in live cells using quantitative phase imaging techniques. Measuring both the 3-D refractive index maps and the dynamic phase images of live cells are simultaneously measured, from which dynamic membrane fluctuation and deformability of cells are precisely calculated. We also present its applications to various diseases ranging from sickle cell diseases, babesiosis, and to diabetes.

  7. Quantitative Measurement of Text Difficulty: What's the Use?

    ERIC Educational Resources Information Center

    Cunningham, James W.; Mesmer, Heidi Anne

    2014-01-01

    Common Core Reading Standard 10 not only prescribes the difficulty of texts students should become able to read, but also the difficulty diet of texts schools should ask their students to read across the school year. The use of quantitative text-assessment tools in the implementation of this standard warrants an examination into the validity of…

  8. Quantitative Measures of Mineral Supply Risk

    NASA Astrophysics Data System (ADS)

    Long, K. R.

    2009-12-01

    Almost all metals and many non-metallic minerals are traded internationally. An advantage of global mineral markets is that minerals can be obtained from the globally lowest-cost source. For example, one rare-earth element (REE) mine in China, Bayan Obo, is able to supply most of world demand for rare earth elements at a cost significantly less than its main competitors. Concentration of global supplies at a single mine raises significant political risks, illustrated by China’s recent decision to prohibit the export of some REEs and severely limit the export of others. The expected loss of REE supplies will have a significant impact on the cost and production of important national defense technologies and on alternative energy programs. Hybrid vehicles and wind-turbine generators, for example, require REEs for magnets and batteries. Compact fluorescent light bulbs use REE-based phosphors. These recent events raise the general issue of how to measure the degree of supply risk for internationally sourced minerals. Two factors, concentration of supply and political risk, must first be addressed. Concentration of supply can be measured with standard economic tools for measuring industry concentration, using countries rather than firms as the unit of analysis. There are many measures of political risk available. That of the OECD is a measure of a country’s commitment to rule-of-law and enforcement of contracts, as well as political stability. Combining these measures provides a comparative view of mineral supply risk across commodities and identifies several minerals other than REEs that could suddenly become less available. Combined with an assessment of the impact of a reduction in supply, decision makers can use these measures to prioritize risk reduction efforts.

  9. Calculator Use on the "GRE"® Revised General Test Quantitative Reasoning Measure. ETS GRE® Board Research Report. ETS GRE®-14-02. ETS Research Report. RR-14-25

    ERIC Educational Resources Information Center

    Attali, Yigal

    2014-01-01

    Previous research on calculator use in standardized assessments of quantitative ability focused on the effect of calculator availability on item difficulty and on whether test developers can predict these effects. With the introduction of an on-screen calculator on the Quantitative Reasoning measure of the "GRE"® revised General Test, it…

  10. Susceptibility Testing by Polymerase Chain Reaction DNA Quantitation: A Method to Measure Drug Resistance of Human Immunodeficiency Virus Type 1 Isolates

    NASA Astrophysics Data System (ADS)

    Eron, Joseph J.; Gorczyca, Paul; Kaplan, Joan C.; D'Aquila, Richard T.

    1992-04-01

    Polymerase chain reaction (PCR) DNA quantitation (PDQ) susceptibility testing rapidly and directly measures nucleoside sensitivity of human immunodeficiency virus type 1 (HIV-1) isolates. PCR is used to quantitate the amount of HIV-1 DNA synthesized after in vitro infection of peripheral blood mononuclear cells. The relative amounts of HIV-1 DNA in cell lysates from cultures maintained at different drug concentrations reflect drug inhibition of virus replication. The results of PDQ susceptibility testing of 2- or 3-day cultures are supported by assays measuring HIV-1 p24 antigen production in supernatants of 7- or 10-day cultures. DNA sequence analyses to identify mutations in the reverse transcriptase gene that cause resistance to 3'-azido-3'-deoxythymidine also support the PDQ results. With the PDQ method, both infectivity titration and susceptibility testing can be performed on supernatants from primary cultures of peripheral blood mononuclear cells. PDQ susceptibility testing should facilitate epidemiologic studies of the clinical significance of drug-resistant HIV-1 isolates.

  11. Fundamental limits of measurement in telecommunications: Experimental and modeling studies in a test optical network on proposal for the reform of telecommunication quantitations

    NASA Astrophysics Data System (ADS)

    Egan, James; McMillan, Normal; Denieffe, David

    2011-08-01

    Proposals for a review of the limits of measurement for telecommunications are made. The measures are based on adapting work from the area of chemical metrology for the field of telecommunications. Currie has introduced recommendations for defining the limits of measurement in chemical metrology and has identified three key fundamental limits of measurement. These are the critical level, the detection limit and the determination limit. Measurements on an optical system are used to illustrate the utility of these measures and discussion is given into the advantages of using these fundamental quantitations over existing methods.

  12. Experimental study of flash boiling spray vaporization through quantitative vapor concentration and liquid temperature measurements

    NASA Astrophysics Data System (ADS)

    Zhang, Gaoming; Hung, David L. S.; Xu, Min

    2014-08-01

    Flash boiling sprays of liquid injection under superheated conditions provide the novel solutions of fast vaporization and better air-fuel mixture formation for internal combustion engines. However, the physical mechanisms of flash boiling spray vaporization are more complicated than the droplet surface vaporization due to the unique bubble generation and boiling process inside a superheated bulk liquid, which are not well understood. In this study, the vaporization of flash boiling sprays was investigated experimentally through the quantitative measurements of vapor concentration and liquid temperature. Specifically, the laser-induced exciplex fluorescence technique was applied to distinguish the liquid and vapor distributions. Quantitative vapor concentration was obtained by correlating the intensity of vapor-phase fluorescence with vapor concentration through systematic corrections and calibrations. The intensities of two wavelengths were captured simultaneously from the liquid-phase fluorescence spectra, and their intensity ratios were correlated with liquid temperature. The results show that both liquid and vapor phase of multi-hole sprays collapse toward the centerline of the spray with different mass distributions under the flash boiling conditions. Large amount of vapor aggregates along the centerline of the spray to form a "gas jet" structure, whereas the liquid distributes more uniformly with large vortexes formed in the vicinity of the spray tip. The vaporization process under the flash boiling condition is greatly enhanced due to the intense bubble generation and burst. The liquid temperature measurements show strong temperature variations inside the flash boiling sprays with hot zones present in the "gas jet" structure and vortex region. In addition, high vapor concentration and closed vortex motion seem to have inhibited the heat and mass transfer in these regions. In summary, the vapor concentration and liquid temperature provide detailed information

  13. The quantitative evaluation of intracranial pressure by optic nerve sheath diameter/eye diameter CT measurement.

    PubMed

    Bekerman, Inessa; Sigal, Tal; Kimiagar, Itzhak; Ben Ely, Anna; Vaiman, Michael

    2016-12-01

    The changes of the optic nerve sheath diameter (ONSD) have been used to assess changes of the intracranial pressure for 20 years. The aim of this research was to further quantify the technique of measuring the ONSD for this purpose. Retrospective study of computed tomographic (CT) data of 1766 adult patients with intracranial hypotension (n=134) or hypertension (n=1632) were analyzed. The eyeball transverse diameter (ETD) and ONSD were obtained bilaterally, and the ONSD/ETD ratio was calculated. The ratio was used to calculate the normal ONSD for patients and to estimate the intracranial pressure of the patients before and after the onset of the pathology. Correlation analysis was performed with invasively measured intracranial pressure, the presence or absence of papilledema, sex, and age. In hypotension cases, the ONSD by CT was 3.4±0.7 mm (P=.03 against normative 4.4±0.8 mm). In cases with hypertension, the diameter was 6.9±1.3 (P=.02, with a cutoff value ˃5.5 mm). The ONSD/ETD ratio was 0.29±0.04 against 0.19±0.02 in healthy adults (P=.01). The ONSD and the ONSD/ETD ratio can indicate low intracranial pressure, but quantification is impossible at intracranial pressure less than 13 mm Hg. In elevated intracranial pressure, the ONSD and the ratio provide readings that correspond to readings in millimeters of mercury. The ONSD method, reinforced with additional calculations, may help to indicate a raised intracranial pressure, evaluate its severity quantitatively, and establish quantitative goals for treatment of intracranial hypertension, but the limitations of the method are to be taken into account. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Bone measurements of infants with hyperbilirubinemia by quantitative ultrasound: the influence of phototherapy.

    PubMed

    Arıkan, Fatma İnci; Kara, Semra; Bilgin, Hüseyin; Özkan, Fatma; Bilge, Yıldız Dallar

    2017-07-01

    The purpose of the current study was to investigate the possible effects of phototherapy on bone status of term infants evaluated by measurement of tibial bone speed of sound (SOS). The phototherapy group (n = 30) consisted of children who had undergone phototherapy for at least 24 h and the control group (n = 30) comprised children who had not received phototherapy. Blood samples were obtained from all infants for serum calcium, phosphorus, magnesium, alkaline phosphatase, parathyroid hormone and vitamin D concentrations. The left tibial quantitative ultrasound (QUS) measurements were performed using a commercial device. There was no statistically significant difference between phototherapy-exposed and nonexposed infants in terms of Ca, P, ALP, PTH and vitamin D levels. Comparison of bone SOS between the phototherapy-exposed and control group revealed no statistically difference. Also, no significant difference in Z-score for SOS was observed between those with or without exposure. The data of our study indicate that phototherapy treatment has no impact on bone status in the hyperbilirubinemic infants. Although there is no statistically significant evidence of an excess risk of bone damage following phototherapy, studies with larger sample sizes and longer duration of follow-up are needed to gain a better understanding of its effects.

  15. Optical properties of acute kidney injury measured by quantitative phase imaging

    PubMed Central

    Ban, Sungbea; Min, Eunjung; Baek, Songyee; Kwon, Hyug Moo; Popescu, Gabriel

    2018-01-01

    The diagnosis of acute kidney disease (AKI) has been examined mainly by histology, immunohistochemistry and western blot. Though these approaches are widely accepted in the field, it has an inherent limitation due to the lack of high-throughput and quantitative information. For a better understanding of prognosis in AKI, we present a new approach using quantitative phase imaging combined with a wide-field scanning platform. Through the phase-delay information from the tissue, we were able to predict a stage of AKI based on various optical properties such as light scattering coefficient and anisotropy. These optical parameters quantify the deterioration process of the AKI model of tissue. Our device would be a very useful tool when it is required to deliver fast feedback of tissue pathology or when diseases are related to mechanical properties such as fibrosis. PMID:29541494

  16. Proposal for a quantitative index of flood disasters.

    PubMed

    Feng, Lihua; Luo, Gaoyuan

    2010-07-01

    Drawing on calculations of wind scale and earthquake magnitude, this paper develops a new quantitative method for measuring flood magnitude and disaster intensity. Flood magnitude is the quantitative index that describes the scale of a flood; the flood's disaster intensity is the quantitative index describing the losses caused. Both indices have numerous theoretical and practical advantages with definable concepts and simple applications, which lend them key practical significance.

  17. Quantitatively accurate activity measurements with a dedicated cardiac SPECT camera: Physical phantom experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pourmoghaddas, Amir, E-mail: apour@ottawaheart.ca; Wells, R. Glenn

    Purpose: Recently, there has been increased interest in dedicated cardiac single photon emission computed tomography (SPECT) scanners with pinhole collimation and improved detector technology due to their improved count sensitivity and resolution over traditional parallel-hole cameras. With traditional cameras, energy-based approaches are often used in the clinic for scatter compensation because they are fast and easily implemented. Some of the cardiac cameras use cadmium-zinc-telluride (CZT) detectors which can complicate the use of energy-based scatter correction (SC) due to the low-energy tail—an increased number of unscattered photons detected with reduced energy. Modified energy-based scatter correction methods can be implemented, but theirmore » level of accuracy is unclear. In this study, the authors validated by physical phantom experiments the quantitative accuracy and reproducibility of easily implemented correction techniques applied to {sup 99m}Tc myocardial imaging with a CZT-detector-based gamma camera with multiple heads, each with a single-pinhole collimator. Methods: Activity in the cardiac compartment of an Anthropomorphic Torso phantom (Data Spectrum Corporation) was measured through 15 {sup 99m}Tc-SPECT acquisitions. The ratio of activity concentrations in organ compartments resembled a clinical {sup 99m}Tc-sestamibi scan and was kept consistent across all experiments (1.2:1 heart to liver and 1.5:1 heart to lung). Two background activity levels were considered: no activity (cold) and an activity concentration 1/10th of the heart (hot). A plastic “lesion” was placed inside of the septal wall of the myocardial insert to simulate the presence of a region without tracer uptake and contrast in this lesion was calculated for all images. The true net activity in each compartment was measured with a dose calibrator (CRC-25R, Capintec, Inc.). A 10 min SPECT image was acquired using a dedicated cardiac camera with CZT detectors (Discovery NM530c

  18. Automatic and quantitative measurement of collagen gel contraction using model-guided segmentation

    NASA Astrophysics Data System (ADS)

    Chen, Hsin-Chen; Yang, Tai-Hua; Thoreson, Andrew R.; Zhao, Chunfeng; Amadio, Peter C.; Sun, Yung-Nien; Su, Fong-Chin; An, Kai-Nan

    2013-08-01

    Quantitative measurement of collagen gel contraction plays a critical role in the field of tissue engineering because it provides spatial-temporal assessment (e.g., changes of gel area and diameter during the contraction process) reflecting the cell behavior and tissue material properties. So far the assessment of collagen gels relies on manual segmentation, which is time-consuming and suffers from serious intra- and inter-observer variability. In this study, we propose an automatic method combining various image processing techniques to resolve these problems. The proposed method first detects the maximal feasible contraction range of circular references (e.g., culture dish) and avoids the interference of irrelevant objects in the given image. Then, a three-step color conversion strategy is applied to normalize and enhance the contrast between the gel and background. We subsequently introduce a deformable circular model which utilizes regional intensity contrast and circular shape constraint to locate the gel boundary. An adaptive weighting scheme was employed to coordinate the model behavior, so that the proposed system can overcome variations of gel boundary appearances at different contraction stages. Two measurements of collagen gels (i.e., area and diameter) can readily be obtained based on the segmentation results. Experimental results, including 120 gel images for accuracy validation, showed high agreement between the proposed method and manual segmentation with an average dice similarity coefficient larger than 0.95. The results also demonstrated obvious improvement in gel contours obtained by the proposed method over two popular, generic segmentation methods.

  19. Quantitative measurement of indomethacin crystallinity in indomethacin-silica gel binary system using differential scanning calorimetry and X-ray powder diffractometry.

    PubMed

    Pan, Xiaohong; Julian, Thomas; Augsburger, Larry

    2006-02-10

    Differential scanning calorimetry (DSC) and X-ray powder diffractometry (XRPD) methods were developed for the quantitative analysis of the crystallinity of indomethacin (IMC) in IMC and silica gel (SG) binary system. The DSC calibration curve exhibited better linearity than that of XRPD. No phase transformation occurred in the IMC-SG mixtures during DSC measurement. The major sources of error in DSC measurements were inhomogeneous mixing and sampling. Analyzing the amount of IMC in the mixtures using high-performance liquid chromatography (HPLC) could reduce the sampling error. DSC demonstrated greater sensitivity and had less variation in measurement than XRPD in quantifying crystalline IMC in the IMC-SG binary system.

  20. Quantitative single-particle digital autoradiography with α-particle emitters for targeted radionuclide therapy using the iQID camera.

    PubMed

    Miller, Brian W; Frost, Sofia H L; Frayo, Shani L; Kenoyer, Aimee L; Santos, Erlinda; Jones, Jon C; Green, Damian J; Hamlin, Donald K; Wilbur, D Scott; Fisher, Darrell R; Orozco, Johnnie J; Press, Oliver W; Pagel, John M; Sandmaier, Brenda M

    2015-07-01

    Alpha-emitting radionuclides exhibit a potential advantage for cancer treatments because they release large amounts of ionizing energy over a few cell diameters (50-80 μm), causing localized, irreparable double-strand DNA breaks that lead to cell death. Radioimmunotherapy (RIT) approaches using monoclonal antibodies labeled with α emitters may thus inactivate targeted cells with minimal radiation damage to surrounding tissues. Tools are needed to visualize and quantify the radioactivity distribution and absorbed doses to targeted and nontargeted cells for accurate dosimetry of all treatment regimens utilizing α particles, including RIT and others (e.g., Ra-223), especially for organs and tumors with heterogeneous radionuclide distributions. The aim of this study was to evaluate and characterize a novel single-particle digital autoradiography imager, the ionizing-radiation quantum imaging detector (iQID) camera, for use in α-RIT experiments. The iQID camera is a scintillator-based radiation detection system that images and identifies charged-particle and gamma-ray/x-ray emissions spatially and temporally on an event-by-event basis. It employs CCD-CMOS cameras and high-performance computing hardware for real-time imaging and activity quantification of tissue sections, approaching cellular resolutions. In this work, the authors evaluated its characteristics for α-particle imaging, including measurements of intrinsic detector spatial resolutions and background count rates at various detector configurations and quantification of activity distributions. The technique was assessed for quantitative imaging of astatine-211 ((211)At) activity distributions in cryosections of murine and canine tissue samples. The highest spatial resolution was measured at ∼20 μm full width at half maximum and the α-particle background was measured at a rate as low as (2.6 ± 0.5) × 10(-4) cpm/cm(2) (40 mm diameter detector area). Simultaneous imaging of multiple tissue sections was

  1. MRI and quantitative autoradiographic studies following bolus injections of unlabeled and 14C-labeled gadolinium-diethylenetriamine-pentaacetic acid in a rat model of stroke yield similar distribution volumes and blood-to-brain influx rate constants

    PubMed Central

    Nagaraja, Tavarekere N.; Ewing, James R.; Karki, Kishor; Jacobs, Paul E.; Divine, George W.; Fenstermacher, Joseph D.; Patlak, Clifford S.; Knight, Robert A.

    2012-01-01

    In previous studies on a rat model of transient cerebral ischemia, the blood and brain concentrations of gadolinium-diethylenetriaminepentaacetic acid (Gd-DTPA) following intravenous bolus injection were repeatedly assessed by dynamic contrast-enhanced (DCE)-MRI, and blood-to-brain influx rate constants (Ki) were calculated from Patlak plots of the data in areas with blood–brain barrier (BBB) opening. For concurrent validation of these findings, after completing the DCE-MRI study, radiolabeled sucrose or α-aminoisobutyric acid was injected intravenously, and the brain disposition and Ki values were calculated by quantitative autoradiography (QAR) assay employing the single-time equation. To overcome two of the shortcomings of this comparison, the present experiments were carried out with a radiotracer virtually identical to Gd-DTPA, Gd-[14C]DTPA, and Ki was calculated from both sets of data by the single-time equation. The protocol included 3 h of middle cerebral artery occlusion and 2.5 h of reperfusion in male Wistar rats (n = 15) preceding the DCE-MRI Gd-DTPA and QAR Gd-[14C]DTPA measurements. In addition to Ki, the tissue-to-blood concentration ratios, or volumes of distribution (VR), were calculated. The regions of BBB opening were similar on the MRI maps and autoradiograms. Within them, VR was nearly identical for Gd-DTPA and Gd-[14C]DTPA, and Ki was slightly, but not significantly, higher for Gd-DTPA than for Gd-[14C]DTPA. The Ki values were well correlated (r = 0.67; p = 0.001). When the arterial concentration–time curve of Gd-DTPA was adjusted to match that of Gd-[14C]DTPA, the two sets of Ki values were equal and statistically comparable with those obtained previously by Patlak plots (the preferred, less model-dependent, approach) of the same data (p = 0.2–0.5). These findings demonstrate that this DCE-MRI technique accurately measures the Gd-DTPA concentration in blood and brain, and that Ki estimates based on such data are good quantitative

  2. A quantitative risk assessment model to evaluate effective border control measures for rabies prevention.

    PubMed

    Weng, Hsin-Yi; Wu, Pei-I; Yang, Ping-Cheng; Tsai, Yi-Lun; Chang, Chao-Chin

    2010-01-01

    Border control is the primary method to prevent rabies emergence. This study developed a quantitative risk model incorporating stochastic processes to evaluate whether border control measures could efficiently prevent rabies introduction through importation of cats and dogs using Taiwan as an example. Both legal importation and illegal smuggling were investigated. The impacts of reduced quarantine and/or waiting period on the risk of rabies introduction were also evaluated. The results showed that Taiwan's current animal importation policy could effectively prevent rabies introduction through legal importation of cats and dogs. The median risk of a rabid animal to penetrate current border control measures and enter Taiwan was 5.33 x 10(-8) (95th percentile: 3.20 x 10(-7)). However, illegal smuggling may pose Taiwan to the great risk of rabies emergence. Reduction of quarantine and/or waiting period would affect the risk differently, depending on the applied assumptions, such as increased vaccination coverage, enforced custom checking, and/or change in number of legal importations. Although the changes in the estimated risk under the assumed alternatives were not substantial except for completely abolishing quarantine, the consequences of rabies introduction may yet be considered to be significant in a rabies-free area. Therefore, a comprehensive benefit-cost analysis needs to be conducted before recommending these alternative measures.

  3. A quantitative risk assessment model to evaluate effective border control measures for rabies prevention

    PubMed Central

    Weng, Hsin-Yi; Wu, Pei-I; Yang, Ping-Cheng; Tsai, Yi-Lun; Chang, Chao-Chin

    2009-01-01

    Border control is the primary method to prevent rabies emergence. This study developed a quantitative risk model incorporating stochastic processes to evaluate whether border control measures could efficiently prevent rabies introduction through importation of cats and dogs using Taiwan as an example. Both legal importation and illegal smuggling were investigated. The impacts of reduced quarantine and/or waiting period on the risk of rabies introduction were also evaluated. The results showed that Taiwan’s current animal importation policy could effectively prevent rabies introduction through legal importation of cats and dogs. The median risk of a rabid animal to penetrate current border control measures and enter Taiwan was 5.33 × 10−8 (95th percentile: 3.20 × 10−7). However, illegal smuggling may pose Taiwan to the great risk of rabies emergence. Reduction of quarantine and/or waiting period would affect the risk differently, depending on the applied assumptions, such as increased vaccination coverage, enforced custom checking, and/or change in number of legal importations. Although the changes in the estimated risk under the assumed alternatives were not substantial except for completely abolishing quarantine, the consequences of rabies introduction may yet be considered to be significant in a rabies-free area. Therefore, a comprehensive benefit-cost analysis needs to be conducted before recommending these alternative measures. PMID:19822125

  4. Quantitative MRI of kidneys in renal disease.

    PubMed

    Kline, Timothy L; Edwards, Marie E; Garg, Ishan; Irazabal, Maria V; Korfiatis, Panagiotis; Harris, Peter C; King, Bernard F; Torres, Vicente E; Venkatesh, Sudhakar K; Erickson, Bradley J

    2018-03-01

    To evaluate the reproducibility and utility of quantitative magnetic resonance imaging (MRI) sequences for the assessment of kidneys in young adults with normal renal function (eGFR ranged from 90 to 130 mL/min/1.73 m 2 ) and patients with early renal disease (autosomal dominant polycystic kidney disease). This prospective case-control study was performed on ten normal young adults (18-30 years old) and ten age- and sex-matched patients with early renal parenchymal disease (autosomal dominant polycystic kidney disease). All subjects underwent a comprehensive kidney MRI protocol, including qualitative imaging: T1w, T2w, FIESTA, and quantitative imaging: 2D cine phase contrast of the renal arteries, and parenchymal diffusion weighted imaging (DWI), magnetization transfer imaging (MTI), blood oxygen level dependent (BOLD) imaging, and magnetic resonance elastography (MRE). The normal controls were imaged on two separate occasions ≥24 h apart (range 24-210 h) to assess reproducibility of the measurements. Quantitative MR imaging sequences were found to be reproducible. The mean ± SD absolute percent difference between quantitative parameters measured ≥24 h apart were: MTI-derived ratio = 4.5 ± 3.6%, DWI-derived apparent diffusion coefficient (ADC) = 6.5 ± 3.4%, BOLD-derived R2* = 7.4 ± 5.9%, and MRE-derived tissue stiffness = 7.6 ± 3.3%. Compared with controls, the ADPKD patient's non-cystic renal parenchyma (NCRP) had statistically significant differences with regard to quantitative parenchymal measures: lower MTI percent ratios (16.3 ± 4.4 vs. 23.8 ± 1.2, p < 0.05), higher ADCs (2.46 ± 0.20 vs. 2.18 ± 0.10 × 10 -3  mm 2 /s, p < 0.05), lower R2*s (14.9 ± 1.7 vs. 18.1 ± 1.6 s -1 , p < 0.05), and lower tissue stiffness (3.2 ± 0.3 vs. 3.8 ± 0.5 kPa, p < 0.05). Excellent reproducibility of the quantitative measurements was obtained in all cases. Significantly different quantitative MR parenchymal

  5. Quantitative Hydrocarbon Surface Analysis

    NASA Technical Reports Server (NTRS)

    Douglas, Vonnie M.

    2000-01-01

    The elimination of ozone depleting substances, such as carbon tetrachloride, has resulted in the use of new analytical techniques for cleanliness verification and contamination sampling. The last remaining application at Rocketdyne which required a replacement technique was the quantitative analysis of hydrocarbons by infrared spectrometry. This application, which previously utilized carbon tetrachloride, was successfully modified using the SOC-400, a compact portable FTIR manufactured by Surface Optics Corporation. This instrument can quantitatively measure and identify hydrocarbons from solvent flush of hardware as well as directly analyze the surface of metallic components without the use of ozone depleting chemicals. Several sampling accessories are utilized to perform analysis for various applications.

  6. Vessel wall characterization using quantitative MRI: what's in a number?

    PubMed

    Coolen, Bram F; Calcagno, Claudia; van Ooij, Pim; Fayad, Zahi A; Strijkers, Gustav J; Nederveen, Aart J

    2018-02-01

    The past decade has witnessed the rapid development of new MRI technology for vessel wall imaging. Today, with advances in MRI hardware and pulse sequences, quantitative MRI of the vessel wall represents a real alternative to conventional qualitative imaging, which is hindered by significant intra- and inter-observer variability. Quantitative MRI can measure several important morphological and functional characteristics of the vessel wall. This review provides a detailed introduction to novel quantitative MRI methods for measuring vessel wall dimensions, plaque composition and permeability, endothelial shear stress and wall stiffness. Together, these methods show the versatility of non-invasive quantitative MRI for probing vascular disease at several stages. These quantitative MRI biomarkers can play an important role in the context of both treatment response monitoring and risk prediction. Given the rapid developments in scan acceleration techniques and novel image reconstruction, we foresee the possibility of integrating the acquisition of multiple quantitative vessel wall parameters within a single scan session.

  7. Quantitative diffusion and swelling kinetic measurements using large-angle interferometric refractometry.

    PubMed

    Saunders, John E; Chen, Hao; Brauer, Chris; Clayton, McGregor; Chen, Weijian; Barnes, Jack A; Loock, Hans-Peter

    2015-12-07

    The uptake and release of sorbates into films and coatings is typically accompanied by changes of the films' refractive index and thickness. We provide a comprehensive model to calculate the concentration of the sorbate from the average refractive index and the film thickness, and validate the model experimentally. The mass fraction of the analyte partitioned into a film is described quantitatively by the Lorentz-Lorenz equation and the Clausius-Mosotti equation. To validate the model, the uptake kinetics of water and other solvents into SU-8 films (d = 40-45 μm) were explored. Large-angle interferometric refractometry measurements can be used to characterize films that are between 15 μm to 150 μm thick and, Fourier analysis, is used to determine independently the thickness, the average refractive index and the refractive index at the film-substrate interface at one-second time intervals. From these values the mass fraction of water in SU-8 was calculated. The kinetics were best described by two independent uptake processes having different rates. Each process followed one-dimensional Fickian diffusion kinetics with diffusion coefficients for water into SU-8 photoresist film of 5.67 × 10(-9) cm(2) s(-1) and 61.2 × 10(-9) cm(2) s(-1).

  8. Simultaneous measurement and quantitation of 4-hydroxyphenylacetic acid and dopamine with fast-scan cyclic voltammetry.

    PubMed

    Shin, Mimi; Kaplan, Sam V; Raider, Kayla D; Johnson, Michael A

    2015-05-07

    Caged compounds have been used extensively to investigate neuronal function in a variety of preparations, including cell culture, ex vivo tissue samples, and in vivo. As a first step toward electrochemically measuring the extent of caged compound photoactivation while also measuring the release of the catecholamine neurotransmitter, dopamine, fast-scan cyclic voltammetry at carbon-fiber microelectrodes (FSCV) was used to electrochemically characterize 4-hydroxyphenylacetic acid (4HPAA) in the absence and presence of dopamine. 4HPAA is a by-product formed during the process of photoactivation of p-hydroxyphenacyl-based caged compounds, such as p-hydroxyphenylglutamate (pHP-Glu). Our data suggest that the oxidation of 4HPAA occurs through the formation of a conjugated species. Moreover, we found that a triangular waveform of -0.4 V to +1.3 V to -0.4 V at 600 V s(-1), repeated every 100 ms, provided an oxidation current of 4HPAA that was enhanced with a limit of detection of 100 nM, while also allowing the detection and quantitation of dopamine within the same scan. Along with quantifying 4HPAA in biological preparations, the results from this work will allow the electrochemical measurement of photoactivation reactions that generate 4HPAA as a by-product as well as provide a framework for measuring the photorelease of electroactive by-products from caged compounds that incorporate other chromophores.

  9. Simultaneous Measurement and Quantitation of 4-Hydroxyphenylacetic acid and Dopamine with Fast-Scan Cyclic Voltammetry

    PubMed Central

    Shin, Mimi; Kaplan, Sam V.; Raider, Kayla D.; Johnson, Michael A.

    2015-01-01

    Caged compounds have been used extensively to investigate neuronal function in a variety of preparations, including cell culture, ex vivo tissue samples, and in vivo. As a first step toward electrochemically measuring the extent of caged compound photoactivation while also measuring the release of the catecholamine neurotransmitter, dopamine, fast-scan cyclic voltammetry at carbon-fiber microelectrodes (FSCV) was used to electrochemically characterize 4-hydroxyphenylacetic acid (4HPAA) in the absence and presence of dopamine. 4HPAA is a by-product formed during the process of photoactivation of p-hydroxyphenylacyl-based caged compounds, such as p-hydroxyphenylglutamate (pHP-Glu). Our data suggest that the oxidation of 4HPAA occurs through the formation of a conjugated species. Moreover, we found that a triangular waveform of −0.4 V to +1.3 V to −0.4 V at 600 V/s, repeated every 100 ms, provided an oxidation current of 4HPAA that was enhanced with a limit of detection of 100 nM, while also allowing the detection and quantitation of dopamine within the same scan. Along with quantifying 4HPAA in biological preparations, the results from this work will allow the electrochemical measurement of photoactivation reactions that generate 4HPAA as a by-product as well as provide a framework for measuring the photorelease of electroactive by-products from caged compounds that incorporate other chromophores. PMID:25785694

  10. Go Figure! Using Quantitative Measures to Enhance Program and Student Success

    ERIC Educational Resources Information Center

    Frost, Leanne H.; Braun, Gwendolyn K.

    2006-01-01

    Using quantitative assessment, Montana State University-Billings substantially improved and expanded its developmental education program and learning center during the past five years. Student-centered questions drove the research efforts. By gathering, analyzing and sharing hard data, the department identified unmet student needs, discovered…

  11. Are Quantitative Measures of Academic Productivity Correlated with Academic Rank in Plastic Surgery? A National Study.

    PubMed

    Susarla, Srinivas M; Lopez, Joseph; Swanson, Edward W; Miller, Devin; O'Brien-Coon, Devin; Zins, James E; Serletti, Joseph M; Yaremchuk, Michael J; Manson, Paul N; Gordon, Chad R

    2015-09-01

    The purpose of this study was to investigate the correlation between quantitative measures of academic productivity and academic rank among full-time academic plastic surgeons. Bibliometric indices were computed for all full-time academic plastic surgeons in the United States. The primary study variable was academic rank. Bibliometric predictors included the Hirsch index, I-10 index, number of publications, number of citations, and highest number of citations for a single publication. Descriptive, bivariate, and correlation analyses were computed. Multiple comparisons testing was used to calculate adjusted associations for subgroups. For all analyses, a value of p < 0.05 was considered significant. The cohort consisted of 607 plastic surgeons across 91 Accreditation Council for Graduate Medical Education-approved programs. Of them, 4.1 percent were instructors/lecturers, 43.7 percent were assistant professors, 22.1 percent were associate professors, 25.7 percent were professors, and 4.4 percent were endowed professors. Mean values were as follows: Hirsch index, 10.2 ± 9.0; I-10 index, 17.2 ± 10.2; total number of publications, 45.5 ± 69.4; total number of citations, 725.0 ± 1448.8; and highest number of citations for a single work, 117.8 ± 262.4. Correlation analyses revealed strong associations of the Hirsch index, I-10 index, number of publications, and number of citations with academic rank (rs = 0.62 to 0.64; p < 0.001). Academic rank in plastic surgery is strongly correlated with several quantitative metrics of research productivity. Although academic promotion is the result of success in multiple different areas, bibliometric measures may be useful adjuncts for assessment of research productivity.

  12. Leadership and Culture-Building in Schools: Quantitative and Qualitative Understandings.

    ERIC Educational Resources Information Center

    Sashkin, Marshall; Sashkin, Molly G.

    Understanding effective school leadership as a function of culture building through quantitative and qualitative analyses is the purpose of this paper. The two-part quantitative phase of the research focused on statistical measures of culture and leadership behavior directed toward culture building in the school. The first quantitative part…

  13. Quantitative Evaluation of MODIS Fire Radiative Power Measurement for Global Smoke Emissions Assessment

    NASA Technical Reports Server (NTRS)

    Ichoku, Charles; Ellison, Luke

    2011-01-01

    Satellite remote sensing is providing us tremendous opportunities to measure the fire radiative energy (FRE) release rate or power (FRP) from open biomass burning, which affects many vegetated regions of the world on a seasonal basis. Knowledge of the biomass burning characteristics and emission source strengths of different (particulate and gaseous) smoke constituents is one of the principal ingredients upon which the assessment, modeling, and forecasting of their distribution and impacts depend. This knowledge can be gained through accurate measurement of FRP, which has been shown to have a direct relationship with the rates of biomass consumption and emissions of major smoke constituents. Over the last decade or so, FRP has been routinely measured from space by both the MODIS sensors aboard the polar orbiting Terra and Aqua satellites, and the SEVIRI sensor aboard the Meteosat Second Generation (MSG) geostationary satellite. During the last few years, FRP has steadily gained increasing recognition as an important parameter for facilitating the development of various scientific studies and applications relating to the quantitative characterization of biomass burning and their emissions. To establish the scientific integrity of the FRP as a stable quantity that can be measured consistently across a variety of sensors and platforms, with the potential of being utilized to develop a unified long-term climate data record of fire activity and impacts, it needs to be thoroughly evaluated, calibrated, and validated. Therefore, we are conducting a detailed analysis of the FRP products from MODIS to evaluate the uncertainties associated with them, such as those due to the effects of satellite variable observation geometry and other factors, in order to establish their error budget for use in diverse scientific research and applications. In this presentation, we will show recent results of the MODIS FRP uncertainty analysis and error mitigation solutions, and demonstrate

  14. Facial Phenotyping by Quantitative Photography Reflects Craniofacial Morphology Measured on Magnetic Resonance Imaging in Icelandic Sleep Apnea Patients

    PubMed Central

    Sutherland, Kate; Schwab, Richard J.; Maislin, Greg; Lee, Richard W.W.; Benedikstdsottir, Bryndis; Pack, Allan I.; Gislason, Thorarinn; Juliusson, Sigurdur; Cistulli, Peter A.

    2014-01-01

    Study Objectives: (1) To determine whether facial phenotype, measured by quantitative photography, relates to underlying craniofacial obstructive sleep apnea (OSA) risk factors, measured with magnetic resonance imaging (MRI); (2) To assess whether these associations are independent of body size and obesity. Design: Cross-sectional cohort. Setting: Landspitali, The National University Hospital, Iceland. Participants: One hundred forty patients (87.1% male) from the Icelandic Sleep Apnea Cohort who had both calibrated frontal and profile craniofacial photographs and upper airway MRI. Mean ± standard deviation age 56.1 ± 10.4 y, body mass index 33.5 ± 5.05 kg/m2, with on-average severe OSA (apnea-hypopnea index 45.4 ± 19.7 h-1). Interventions: N/A. Measurements and Results: Relationships between surface facial dimensions (photos) and facial bony dimensions and upper airway soft-tissue volumes (MRI) was assessed using canonical correlation analysis. Photo and MRI craniofacial datasets related in four significant canonical correlations, primarily driven by measurements of (1) maxillary-mandibular relationship (r = 0.8, P < 0.0001), (2) lower face height (r = 0.76, P < 0.0001), (3) mandibular length (r = 0.67, P < 0.0001), and (4) tongue volume (r = 0.52, P = 0.01). Correlations 1, 2, and 3 were unchanged when controlled for weight and neck and waist circumference. However, tongue volume was no longer significant, suggesting facial dimensions relate to tongue volume as a result of obesity. Conclusions: Significant associations were found between craniofacial variable sets from facial photography and MRI. This study confirms that facial photographic phenotype reflects underlying aspects of craniofacial skeletal abnormalities associated with OSA. Therefore, facial photographic phenotyping may be a useful tool to assess intermediate phenotypes for OSA, particularly in large-scale studies. Citation: Sutherland K, Schwab RJ, Maislin G, Lee RW, Benedikstdsottir B, Pack AI

  15. Refining the quantitative pathway of the Pathways to Mathematics model.

    PubMed

    Sowinski, Carla; LeFevre, Jo-Anne; Skwarchuk, Sheri-Lynn; Kamawar, Deepthi; Bisanz, Jeffrey; Smith-Chant, Brenda

    2015-03-01

    In the current study, we adopted the Pathways to Mathematics model of LeFevre et al. (2010). In this model, there are three cognitive domains--labeled as the quantitative, linguistic, and working memory pathways--that make unique contributions to children's mathematical development. We attempted to refine the quantitative pathway by combining children's (N=141 in Grades 2 and 3) subitizing, counting, and symbolic magnitude comparison skills using principal components analysis. The quantitative pathway was examined in relation to dependent numerical measures (backward counting, arithmetic fluency, calculation, and number system knowledge) and a dependent reading measure, while simultaneously accounting for linguistic and working memory skills. Analyses controlled for processing speed, parental education, and gender. We hypothesized that the quantitative, linguistic, and working memory pathways would account for unique variance in the numerical outcomes; this was the case for backward counting and arithmetic fluency. However, only the quantitative and linguistic pathways (not working memory) accounted for unique variance in calculation and number system knowledge. Not surprisingly, only the linguistic pathway accounted for unique variance in the reading measure. These findings suggest that the relative contributions of quantitative, linguistic, and working memory skills vary depending on the specific cognitive task. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Confirmatory factor analytic structure and measurement invariance of quantitative autistic traits measured by the social responsiveness scale-2.

    PubMed

    Frazier, Thomas W; Ratliff, Kristin R; Gruber, Chris; Zhang, Yi; Law, Paul A; Constantino, John N

    2014-01-01

    Understanding the factor structure of autistic symptomatology is critical to the discovery and interpretation of causal mechanisms in autism spectrum disorder. We applied confirmatory factor analysis and assessment of measurement invariance to a large (N = 9635) accumulated collection of reports on quantitative autistic traits using the Social Responsiveness Scale, representing a broad diversity of age, severity, and reporter type. A two-factor structure (corresponding to social communication impairment and restricted, repetitive behavior) as elaborated in the updated Diagnostic and Statistical Manual of Mental Disorders (5th ed.; DSM-5) criteria for autism spectrum disorder exhibited acceptable model fit in confirmatory factor analysis. Measurement invariance was appreciable across age, sex, and reporter (self vs other), but somewhat less apparent between clinical and nonclinical populations in this sample comprised of both familial and sporadic autism spectrum disorders. The statistical power afforded by this large sample allowed relative differentiation of three factors among items encompassing social communication impairment (emotion recognition, social avoidance, and interpersonal relatedness) and two factors among items encompassing restricted, repetitive behavior (insistence on sameness and repetitive mannerisms). Cross-trait correlations remained extremely high, that is, on the order of 0.66-0.92. These data clarify domains of statistically significant factoral separation that may relate to partially-but not completely-overlapping biological mechanisms, contributing to variation in human social competency. Given such robust intercorrelations among symptom domains, understanding their co-emergence remains a high priority in conceptualizing common neural mechanisms underlying autistic syndromes.

  17. Overview of classical test theory and item response theory for the quantitative assessment of items in developing patient-reported outcomes measures.

    PubMed

    Cappelleri, Joseph C; Jason Lundy, J; Hays, Ron D

    2014-05-01

    The US Food and Drug Administration's guidance for industry document on patient-reported outcomes (PRO) defines content validity as "the extent to which the instrument measures the concept of interest" (FDA, 2009, p. 12). According to Strauss and Smith (2009), construct validity "is now generally viewed as a unifying form of validity for psychological measurements, subsuming both content and criterion validity" (p. 7). Hence, both qualitative and quantitative information are essential in evaluating the validity of measures. We review classical test theory and item response theory (IRT) approaches to evaluating PRO measures, including frequency of responses to each category of the items in a multi-item scale, the distribution of scale scores, floor and ceiling effects, the relationship between item response options and the total score, and the extent to which hypothesized "difficulty" (severity) order of items is represented by observed responses. If a researcher has few qualitative data and wants to get preliminary information about the content validity of the instrument, then descriptive assessments using classical test theory should be the first step. As the sample size grows during subsequent stages of instrument development, confidence in the numerical estimates from Rasch and other IRT models (as well as those of classical test theory) would also grow. Classical test theory and IRT can be useful in providing a quantitative assessment of items and scales during the content-validity phase of PRO-measure development. Depending on the particular type of measure and the specific circumstances, the classical test theory and/or the IRT should be considered to help maximize the content validity of PRO measures. Copyright © 2014 Elsevier HS Journals, Inc. All rights reserved.

  18. Biomarkers and Surrogate Endpoints in Uveitis: The Impact of Quantitative Imaging.

    PubMed

    Denniston, Alastair K; Keane, Pearse A; Srivastava, Sunil K

    2017-05-01

    Uveitis is a major cause of sight loss across the world. The reliable assessment of intraocular inflammation in uveitis ('disease activity') is essential in order to score disease severity and response to treatment. In this review, we describe how 'quantitative imaging', the approach of using automated analysis and measurement algorithms across both standard and emerging imaging modalities, can develop objective instrument-based measures of disease activity. This is a narrative review based on searches of the current world literature using terms related to quantitative imaging techniques in uveitis, supplemented by clinical trial registry data, and expert knowledge of surrogate endpoints and outcome measures in ophthalmology. Current measures of disease activity are largely based on subjective clinical estimation, and are relatively insensitive, with poor discrimination and reliability. The development of quantitative imaging in uveitis is most established in the use of optical coherence tomographic (OCT) measurement of central macular thickness (CMT) to measure severity of macular edema (ME). The transformative effect of CMT in clinical assessment of patients with ME provides a paradigm for the development and impact of other forms of quantitative imaging. Quantitative imaging approaches are now being developed and validated for other key inflammatory parameters such as anterior chamber cells, vitreous haze, retinovascular leakage, and chorioretinal infiltrates. As new forms of quantitative imaging in uveitis are proposed, the uveitis community will need to evaluate these tools against the current subjective clinical estimates and reach a new consensus for how disease activity in uveitis should be measured. The development, validation, and adoption of sensitive and discriminatory measures of disease activity is an unmet need that has the potential to transform both drug development and routine clinical care for the patient with uveitis.

  19. Direct quantitative measurement of the C═O⋅⋅⋅H–C bond by atomic force microscopy

    PubMed Central

    Kawai, Shigeki; Nishiuchi, Tomohiko; Kodama, Takuya; Spijker, Peter; Pawlak, Rémy; Meier, Tobias; Tracey, John; Kubo, Takashi; Meyer, Ernst; Foster, Adam S.

    2017-01-01

    The hydrogen atom—the smallest and most abundant atom—is of utmost importance in physics and chemistry. Although many analysis methods have been applied to its study, direct observation of hydrogen atoms in a single molecule remains largely unexplored. We use atomic force microscopy (AFM) to resolve the outermost hydrogen atoms of propellane molecules via very weak C═O⋅⋅⋅H–C hydrogen bonding just before the onset of Pauli repulsion. The direct measurement of the interaction with a hydrogen atom paves the way for the identification of three-dimensional molecules such as DNAs and polymers, building the capabilities of AFM toward quantitative probing of local chemical reactivity. PMID:28508080

  20. Quantitative Phase Determination by Using a Michelson Interferometer

    ERIC Educational Resources Information Center

    Pomarico, Juan A.; Molina, Pablo F.; D'Angelo, Cristian

    2007-01-01

    The Michelson interferometer is one of the best established tools for quantitative interferometric measurements. It has been, and is still successfully used, not only for scientific purposes, but it is also introduced in undergraduate courses for qualitative demonstrations as well as for quantitative determination of several properties such as…

  1. Quantitative method of measuring cancer cell urokinase and metastatic potential

    NASA Technical Reports Server (NTRS)

    Morrison, Dennis R. (Inventor)

    1993-01-01

    The metastatic potential of tumors can be evaluated by the quantitative detection of urokinase and DNA. The cell sample selected for examination is analyzed for the presence of high levels of urokinase and abnormal DNA using analytical flow cytometry and digital image analysis. Other factors such as membrane associated urokinase, increased DNA synthesis rates and certain receptors can be used in the method for detection of potentially invasive tumors.

  2. Validity of a quantitative clinical measurement tool of trunk posture in idiopathic scoliosis.

    PubMed

    Fortin, Carole; Feldman, Debbie E; Cheriet, Farida; Labelle, Hubert

    2010-09-01

    Concurrent validity between postural indices obtained from digital photographs (two-dimensional [2D]), surface topography imaging (three-dimensional [3D]), and radiographs. To assess the validity of a quantitative clinical postural assessment tool of the trunk based on photographs (2D) as compared to a surface topography system (3D) as well as indices calculated from radiographs. To monitor progression of scoliosis or change in posture over time in young persons with idiopathic scoliosis (IS), noninvasive and nonionizing methods are recommended. In a clinical setting, posture can be quite easily assessed by calculating key postural indices from photographs. Quantitative postural indices of 70 subjects aged 10 to 20 years old with IS (Cobb angle, 15 degrees -60 degrees) were measured from photographs and from 3D trunk surface images taken in the standing position. Shoulder, scapula, trunk list, pelvis, scoliosis, and waist angles indices were calculated with specially designed software. Frontal and sagittal Cobb angles and trunk list were also calculated on radiographs. The Pearson correlation coefficients (r) was used to estimate concurrent validity of the 2D clinical postural tool of the trunk with indices extracted from the 3D system and with those obtained from radiographs. The correlation between 2D and 3D indices was good to excellent for shoulder, pelvis, trunk list, and thoracic scoliosis (0.81>r<0.97; P<0.01) but fair to moderate for thoracic kyphosis, lumbar lordosis, and thoracolumbar or lumbar scoliosis (0.30>r<0.56; P<0.05). The correlation between 2D and radiograph spinal indices was fair to good (-0.33 to -0.80 with Cobb angles and 0.76 for trunk list; P<0.05). This tool will facilitate clinical practice by monitoring trunk posture among persons with IS. Further, it may contribute to a reduction in the use of radiographs to monitor scoliosis progression.

  3. Evaluation of the default-mode network by quantitative 15O-PET: comparative study between cerebral blood flow and oxygen consumption.

    PubMed

    Aoe, Jo; Watabe, Tadashi; Shimosegawa, Eku; Kato, Hiroki; Kanai, Yasukazu; Naka, Sadahiro; Matsunaga, Keiko; Isohashi, Kayako; Tatsumi, Mitsuaki; Hatazawa, Jun

    2018-06-22

    Resting-state functional MRI (rs-fMRI) has revealed the existence of a default-mode network (DMN) based on spontaneous oscillations of the blood oxygenation level-dependent (BOLD) signal. The BOLD signal reflects the deoxyhemoglobin concentration, which depends on the relationship between the regional cerebral blood flow (CBF) and the cerebral metabolic rate of oxygen (CMRO 2 ). However, these two factors cannot be separated in BOLD rs-fMRI. In this study, we attempted to estimate the functional correlations in the DMN by means of quantitative 15 O-labeled gases and water PET, and to compare the contribution of the CBF and CMRO 2 to the DMN. Nine healthy volunteers (5 men and 4 women; mean age, 47.0 ± 1.2 years) were studied by means of 15 O-O 2 , 15 O-CO gases and 15 O-water PET. Quantitative CBF and CMRO 2 images were generated by an autoradiographic method and transformed into MNI standardized brain template. Regions of interest were placed on normalized PET images according to the previous rs-fMRI study. For the functional correlation analysis, the intersubject Pearson's correlation coefficients (r) were calculated for all pairs in the brain regions and correlation matrices were obtained for CBF and CMRO 2 , respectively. We defined r > 0.7 as a significant positive correlation and compared the correlation matrices of CBF and CMRO 2 . Significant positive correlations (r > 0.7) were observed in 24 pairs of brain regions for the CBF and 22 pairs of brain regions for the CMRO 2 . Among them, 12 overlapping networks were observed between CBF and CMRO 2 . Correlation analysis of CBF led to the detection of more brain networks as compared to that of CMRO 2 , indicating that the CBF can capture the state of the spontaneous activity with a higher sensitivity. We estimated the functional correlations in the DMN by means of quantitative PET using 15 O-labeled gases and water. The correlation matrix derived from the CBF revealed a larger number of brain

  4. Distinguishing nanomaterial particles from background airborne particulate matter for quantitative exposure assessment

    NASA Astrophysics Data System (ADS)

    Ono-Ogasawara, Mariko; Serita, Fumio; Takaya, Mitsutoshi

    2009-10-01

    As the production of engineered nanomaterials quantitatively expands, the chance that workers involved in the manufacturing process will be exposed to nanoparticles also increases. A risk management system is needed for workplaces in the nanomaterial industry based on the precautionary principle. One of the problems in the risk management system is difficulty of exposure assessment. In this article, examples of exposure assessment in nanomaterial industries are reviewed with a focus on distinguishing engineered nanomaterial particles from background nanoparticles in workplace atmosphere. An approach by JNIOSH (Japan National Institute of Occupational Safety and Health) to quantitatively measure exposure to carbonaceous nanomaterials is also introduced. In addition to real-time measurements and qualitative analysis by electron microscopy, quantitative chemical analysis is necessary for quantitatively assessing exposure to nanomaterials. Chemical analysis is suitable for quantitative exposure measurement especially at facilities with high levels of background NPs.

  5. Quantitative measurement of transverse injector and free stream interaction in a nonreacting SCRAMJET combustor using laser-induced iodine fluorescence

    NASA Technical Reports Server (NTRS)

    Fletcher, D. G.; Mcdaniel, J. C.

    1987-01-01

    A preliminary quantitative study of the compressible flowfield in a steady, nonreacting model SCRAMJET combustor using laser-induced iodine fluorescence (LIIF) is reported. Measurements of density, temperature, and velocity were conducted with the calibrated, nonintrusive, optical technique for two different combustor operating conditions. First, measurements were made in the supersonic flow over a rearward-facing step without transverse injection for comparison with calculated pressure profiles. The second configuration was staged injection behind the rearward-facing step at an injection dynamic pressure ratio of 1.06. These experimental results will be used to validate computational fluid dynamic (CFD) codes being developed to model supersonic combustor flowfields.

  6. Phase calibration target for quantitative phase imaging with ptychography.

    PubMed

    Godden, T M; Muñiz-Piniella, A; Claverley, J D; Yacoot, A; Humphry, M J

    2016-04-04

    Quantitative phase imaging (QPI) utilizes refractive index and thickness variations that lead to optical phase shifts. This gives contrast to images of transparent objects. In quantitative biology, phase images are used to accurately segment cells and calculate properties such as dry mass, volume and proliferation rate. The fidelity of the measured phase shifts is of critical importance in this field. However to date, there has been no standardized method for characterizing the performance of phase imaging systems. Consequently, there is an increasing need for protocols to test the performance of phase imaging systems using well-defined phase calibration and resolution targets. In this work, we present a candidate for a standardized phase resolution target, and measurement protocol for the determination of the transfer of spatial frequencies, and sensitivity of a phase imaging system. The target has been carefully designed to contain well-defined depth variations over a broadband range of spatial frequencies. In order to demonstrate the utility of the target, we measure quantitative phase images on a ptychographic microscope, and compare the measured optical phase shifts with Atomic Force Microscopy (AFM) topography maps and surface profile measurements from coherence scanning interferometry. The results show that ptychography has fully quantitative nanometer sensitivity in optical path differences over a broadband range of spatial frequencies for feature sizes ranging from micrometers to hundreds of micrometers.

  7. Quantitative fetal fibronectin testing in combination with cervical length measurement in the prediction of spontaneous preterm delivery in symptomatic women.

    PubMed

    Bruijn, Mmc; Vis, J Y; Wilms, F F; Oudijk, M A; Kwee, A; Porath, M M; Oei, G; Scheepers, Hcj; Spaanderman, Mea; Bloemenkamp, Kwm; Haak, M C; Bolte, A C; Vandenbussche, Fpha; Woiski, M D; Bax, C J; Cornette, Jmj; Duvekot, J J; Nij Bijvanck, Bwa; van Eyck, J; Franssen, Mtm; Sollie, K M; van der Post, Jam; Bossuyt, Pmm; Opmeer, B C; Kok, M; Mol, Bwj; van Baaren, G-J

    2016-11-01

    To evaluate whether in symptomatic women, the combination of quantitative fetal fibronectin (fFN) testing and cervical length (CL) improves the prediction of preterm delivery (PTD) within 7 days compared with qualitative fFN and CL. Post hoc analysis of frozen fFN samples of a nationwide cohort study. Ten perinatal centres in the Netherlands. Symptomatic women between 24 and 34 weeks of gestation. The risk of PTD <7 days was estimated in predefined CL and fFN strata. We used logistic regression to develop a model including quantitative fFN and CL, and one including qualitative fFN (threshold 50 ng/ml) and CL. We compared the models' capacity to identify women at low risk (<5%) for delivery within 7 days using a reclassification table. Spontaneous delivery within 7 days after study entry. We studied 350 women, of whom 69 (20%) delivered within 7 days. The risk of PTD in <7 days ranged from 2% in the lowest fFN group (<10 ng/ml) to 71% in the highest group (>500 ng/ml). Multivariable logistic regression showed an increasing risk of PTD in <7 days with rising fFN concentration [10-49 ng/ml: odds ratio (OR) 1.3, 95% confidence interval (95% CI) 0.23-7.0; 50-199 ng/ml: OR 3.2, 95% CI 0.79-13; 200-499 ng/ml: OR 9.0, 95% CI 2.3-35; >500 ng/ml: OR 39, 95% CI 9.4-164] and shortening of the CL (OR 0.86 per mm, 95% CI 0.82-0.90). Use of quantitative fFN instead of qualitative fFN resulted in reclassification of 18 (5%) women from high to low risk, of whom one (6%) woman delivered within 7 days. In symptomatic women, quantitative fFN testing does not improve the prediction of PTD within 7 days compared with qualitative fFN testing in combination with CL measurement in terms of reclassification from high to low (<5%) risk, but it adds value across the risk range. Quantitative fFN testing adds value to qualitative fFN testing with CL measurement in the prediction of PTD. © 2015 Royal College of Obstetricians and Gynaecologists.

  8. Prototype ultrasonic instrument for quantitative testing

    NASA Technical Reports Server (NTRS)

    Lynnworth, L. C.; Dubois, J. L.; Kranz, P. R.

    1972-01-01

    A prototype ultrasonic instrument has been designed and developed for quantitative testing. The complete delivered instrument consists of a pulser/receiver which plugs into a standard oscilloscope, an rf power amplifier, a standard decade oscillator, and a set of broadband transducers for typical use at 1, 2, 5 and 10 MHz. The system provides for its own calibration, and on the oscilloscope, presents a quantitative (digital) indication of time base and sensitivity scale factors and some measurement data.

  9. Quantitative measurement of zinc secretion from pancreatic islets with high temporal resolution using droplet-based microfluidics.

    PubMed

    Easley, Christopher J; Rocheleau, Jonathan V; Head, W Steven; Piston, David W

    2009-11-01

    We assayed glucose-stimulated insulin secretion (GSIS) from live, murine islets of Langerhans in microfluidic devices by the downstream formation of aqueous droplets. Zinc ions, which are cosecreted with insulin from beta-cells, were quantitatively measured from single islets with high temporal resolution using a fluorescent indicator, FluoZin-3. Real-time storage of secretions into droplets (volume of 0.470 +/- 0.009 nL) effectively preserves the temporal chemical information, allowing reconstruction of the secretory time record. The use of passive flow control within the device removes the need for syringe pumps, requiring only a single hand-held syringe. Under stimulatory glucose levels (11 mM), bursts of zinc as high as approximately 800 fg islet(-1) min(-1) were measured. Treatment with diazoxide effectively blocked zinc secretion, as expected. High temporal resolution reveals two major classes of oscillations in secreted zinc, with predominate periods at approximately 20-40 s and approximately 5-10 min. The more rapid oscillation periods match closely with those of intraislet calcium oscillations, while the slower oscillations are consistent with insulin pulses typically measured in bulk islet experiments or in the bloodstream. This droplet sampling technique should be widely applicable to time-resolved cellular secretion measurements, either in real-time or for postprocessing.

  10. Quantitative measurement of zinc secretion from pancreatic islets with high temporal resolution using droplet-based microfluidics

    PubMed Central

    Easley, Christopher J.; Rocheleau, Jonathan V.; Head, W. Steven; Piston, David W.

    2009-01-01

    We assayed glucose-stimulated insulin secretion (GSIS) from live, murine islets of Langerhans in microfluidic devices by the downstream formation of aqueous droplets. Zinc ions, which are co-secreted with insulin from β-cells, were quantitatively measured from single islets with high temporal resolution using a fluorescent indicator, FluoZin-3. Real-time storage of secretions into droplets (volume of 0.470 ± 0.009 nL) effectively preserves the temporal chemical information, allowing reconstruction of the secretory time record. The use of passive flow control within the device removes the need for syringe pumps, requiring only a single handheld syringe. Under stimulatory glucose levels (11 mM), bursts of zinc as high as ~800 fg islet−1 min−1 were measured. Treatment with diazoxide effectively blocked zinc secretion, as expected. High temporal resolution reveals two major classes of oscillations in secreted zinc, with predominate periods at ~20-40 s and ~ 5-10 min. The more rapid oscillation periods match closely with those of intraislet calcium oscillations, while the slower oscillations are consistent with insulin pulses typically measured in bulk islet experiments or in the bloodstream. This droplet sampling technique should be widely applicable to time-resolved cellular secretion measurements, either in real-time or for post-processing. PMID:19874061

  11. Quantitative measurements of regional glucose utilization and rate of valine incorporation into proteins by double-tracer autoradiography in the rat brain tumor model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kirikae, M.; Diksic, M.; Yamamoto, Y.L.

    1989-02-01

    We examined the rate of glucose utilization and the rate of valine incorporation into proteins using 2-(/sup 18/F)fluoro-2-deoxyglucose and L-(1-14C)-valine in a rat brain tumor model by quantitative double-tracer autoradiography. We found that in the implanted tumor the rate of valine incorporation into proteins was about 22 times and the rate of glucose utilization was about 1.5 times that in the contralateral cortex. (In the ipsilateral cortex, the tumor had a profound effect on glucose utilization but no effect on the rate of valine incorporation into proteins.) Our findings suggest that it is more useful to measure protein synthesis thanmore » glucose utilization to assess the effectiveness of antitumor agents and their toxicity to normal brain tissue. We compared two methods to estimate the rate of valine incorporation: kinetic (quantitation done using an operational equation and the average brain rate coefficients) and washed slices (unbound labeled valine removed by washing brain slices in 10% trichloroacetic acid). The results were the same using either method. It would seem that the kinetic method can thus be used for quantitative measurement of protein synthesis in brain tumors and normal brain tissue using (/sup 11/C)-valine with positron emission tomography.« less

  12. Validation of a new UNIX-based quantitative coronary angiographic system for the measurement of coronary artery lesions.

    PubMed

    Bell, M R; Britson, P J; Chu, A; Holmes, D R; Bresnahan, J F; Schwartz, R S

    1997-01-01

    We describe a method of validation of computerized quantitative coronary arteriography and report the results of a new UNIX-based quantitative coronary arteriography software program developed for rapid on-line (digital) and off-line (digital or cinefilm) analysis. The UNIX operating system is widely available in computer systems using very fast processors and has excellent graphics capabilities. The system is potentially compatible with any cardiac digital x-ray system for on-line analysis and has been designed to incorporate an integrated database, have on-line and immediate recall capabilities, and provide digital access to all data. The accuracy (mean signed differences of the observed minus the true dimensions) and precision (pooled standard deviations of the measurements) of the program were determined x-ray vessel phantoms. Intra- and interobserver variabilities were assessed from in vivo studies during routine clinical coronary arteriography. Precision from the x-ray phantom studies (6-In. field of view) for digital images was 0.066 mm and for digitized cine images was 0.060 mm. Accuracy was 0.076 mm (overestimation) for digital images compared to 0.008 mm for digitized cine images. Diagnostic coronary catheters were also used for calibration; accuracy.varied according to size of catheter and whether or not they were filled with iodinated contrast. Intra- and interobserver variabilities were excellent and indicated that coronary lesion measurements were relatively user-independent. Thus, this easy to use and very fast UNIX based program appears to be robust with optimal accuracy and precision for clinical and research applications.

  13. A Quantitative Approach to Assessing System Evolvability

    NASA Technical Reports Server (NTRS)

    Christian, John A., III

    2004-01-01

    When selecting a system from multiple candidates, the customer seeks the one that best meets his or her needs. Recently the desire for evolvable systems has become more important and engineers are striving to develop systems that accommodate this need. In response to this search for evolvability, we present a historical perspective on evolvability, propose a refined definition of evolvability, and develop a quantitative method for measuring this property. We address this quantitative methodology from both a theoretical and practical perspective. This quantitative model is then applied to the problem of evolving a lunar mission to a Mars mission as a case study.

  14. Quantitative Measurements of X-ray Intensity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haugh, M. J., Schneider, M.

    This chapter describes the characterization of several X-ray sources and their use in calibrating different types of X-ray cameras at National Security Technologies, LLC (NSTec). The cameras are employed in experimental plasma studies at Lawrence Livermore National Laboratory (LLNL), including the National Ignition Facility (NIF). The sources provide X-rays in the energy range from several hundred eV to 110 keV. The key to this effort is measuring the X-ray beam intensity accurately and traceable to international standards. This is accomplished using photodiodes of several types that are calibrated using radioactive sources and a synchrotron source using methods and materials thatmore » are traceable to the U.S. National Institute of Standards and Technology (NIST). The accreditation procedures are described. The chapter begins with an introduction to the fundamental concepts of X-ray physics. The types of X-ray sources that are used for device calibration are described. The next section describes the photodiode types that are used for measuring X-ray intensity: power measuring photodiodes, energy dispersive photodiodes, and cameras comprising photodiodes as pixel elements. Following their description, the methods used to calibrate the primary detectors, the power measuring photodiodes and the energy dispersive photodiodes, as well as the method used to get traceability to international standards are described. The X-ray source beams can then be measured using the primary detectors. The final section then describes the use of the calibrated X-ray beams to calibrate X-ray cameras. Many of the references are web sites that provide databases, explanations of the data and how it was generated, and data calculations for specific cases. Several general reference books related to the major topics are included. Papers expanding some subjects are cited.« less

  15. Measurement of bone marrow lesions by MR imaging in knee osteoarthritis using quantitative segmentation methods--a reliability and sensitivity to change analysis.

    PubMed

    Nielsen, Flemming K; Egund, Niels; Peters, David; Jurik, Anne Grethe

    2014-12-20

    Longitudinal assessment of bone marrow lesions (BMLs) in knee osteoarthritis (KOA) by MRI is usually performed using semi-quantitative grading methods. Quantitative segmentation methods may be more sensitive to detect change over time. The purpose of this study was to evaluate and compare the validity and sensitivity to detect changes of two quantitative MR segmentation methods for measuring BMLs in KOA, one computer assisted (CAS) and one manual (MS) method. Twenty-two patients with KOA confined to the medial femoro-tibial compartment obtained MRI at baseline and follow-up (median 334 days in between). STIR, T1 and fat saturated T1 post-contrast sequences were obtained using a 1.5 T system. The 44 sagittal STIR sequences were assessed independently by two readers for quantification of BML. The signal intensities (SIs) of the normal bone marrow in the lateral femoral condyles and tibial plateaus were used as threshold values. The volume of bone marrow with SIs exceeding the threshold values (BML) was measured in the medial femoral condyle and tibial plateau and related to the total volume of the condyles/plateaus.The 95% limits of agreement at baseline were used to determine the sensitivity to change. The mean threshold values of CAS and MS were almost identical but the absolute and relative BML volumes differed being 1319 mm3/10% and 1828 mm3/15% in the femur and 941 mm3/7% and 2097 mm3/18% in the tibia using CAS and MS, respectively. The BML volumes obtained by CAS and MS were significantly correlated but the tissue changes measured were different. The volume of voxels exceeding the threshold values was measured by CAS whereas MS included intervening voxels with normal SI.The 95% limits of agreement were narrower by CAS than by MS; a significant change of relative BML by CAS was outside the limits of -2.0%-4.7% whereas the limits by MS were -6.9%-8.2%. The BML changed significantly in 13 knees using CAS and in 10 knees by MS. CAS was a reliable method for

  16. Quantitative outcome measures for systemic sclerosis-related Microangiopathy - Reliability of image acquisition in Nailfold Capillaroscopy.

    PubMed

    Dinsdale, Graham; Moore, Tonia; O'Leary, Neil; Berks, Michael; Roberts, Christopher; Manning, Joanne; Allen, John; Anderson, Marina; Cutolo, Maurizio; Hesselstrand, Roger; Howell, Kevin; Pizzorni, Carmen; Smith, Vanessa; Sulli, Alberto; Wildt, Marie; Taylor, Christopher; Murray, Andrea; Herrick, Ariane L

    2017-09-01

    Nailfold capillaroscopic parameters hold increasing promise as outcome measures for clinical trials in systemic sclerosis (SSc). Their inclusion as outcomes would often naturally require capillaroscopy images to be captured at several time points during any one study. Our objective was to assess repeatability of image acquisition (which has been little studied), as well as of measurement. 41 patients (26 with SSc, 15 with primary Raynaud's phenomenon) and 10 healthy controls returned for repeat high-magnification (300×) videocapillaroscopy mosaic imaging of 10 digits one week after initial imaging (as part of a larger study of reliability). Images were assessed in a random order by an expert blinded observer and 4 outcome measures extracted: (1) overall image grade and then (where possible) distal vessel locations were marked, allowing (2) vessel density (across the whole nailfold) to be calculated (3) apex width measurement and (4) giant vessel count. Intra-rater, intra-visit and intra-rater inter-visit (baseline vs. 1week) reliability were examined in 475 and 392 images respectively. A linear, mixed-effects model was used to estimate variance components, from which intra-class correlation coefficients (ICCs) were determined. Intra-visit and inter-visit reliability estimates (ICCs) were (respectively): overall image grade, 0.97 and 0.90; vessel density, 0.92 and 0.65; mean vessel width, 0.91 and 0.79; presence of giant capillary, 0.68 and 0.56. These estimates were conditional on each parameter being measurable. Within-operator image analysis and acquisition are reproducible. Quantitative nailfold capillaroscopy, at least with a single observer, provides reliable outcome measures for clinical studies including randomised controlled trials. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Flow cytometric determination of quantitative immunophenotypes

    NASA Astrophysics Data System (ADS)

    Redelman, Douglas; Ensign, Wayne; Roberts, Don

    2001-05-01

    Immunofluorescent flow cytometric analysis of peripheral blood leucocytes is most commonly used to identify and enumerate cells defined by one or more clusters of differentiation (CD) antigens. Although less widely employed, quantitative tests that measure the amounts of CD antigens expressed per cell are used in some situations such as the characterization of lymphomas and leukocytes or the measurement of CD38 on CD3plu8pluT cells in HIV infected individuals. The CD antigens used to identify leukocyte populations are functionally important molecules and it is known that under- or over-expression of some CD antigens can affect cellular responses. For example, high or low expression of CD19 on B cells is associated with autoimmune conditions or depressed antibody responses, respectively. In the current studies, the quantitative expression of CD antigens on T cells, B cells and monocytes was determined in a group of age and sex-matched Marines at several times before and after training exercises. There was substantial variation among these individuals in the quantitative expression of CD antigens and in the number of cells in various populations. However, there was relatively little variation within individuals during the two months they were examined. Thus, the number of cells in leukocyte sub-populations and the amount of CD antigens expressed per cell appear to comprise a characteristic quantitative immunophenotype.

  18. Integration of Quantitative Positron Emission Tomography Absolute Myocardial Blood Flow Measurements in the Clinical Management of Coronary Artery Disease.

    PubMed

    Gewirtz, Henry; Dilsizian, Vasken

    2016-05-31

    In the >40 years since planar myocardial imaging with(43)K-potassium was introduced into clinical research and management of patients with coronary artery disease (CAD), diagnosis and treatment have undergone profound scientific and technological changes. One such innovation is the current state-of-the-art hardware and software for positron emission tomography myocardial perfusion imaging, which has advanced it from a strictly research-oriented modality to a clinically valuable tool. This review traces the evolving role of quantitative positron emission tomography measurements of myocardial blood flow in the evaluation and management of patients with CAD. It presents methodology, currently or soon to be available, that offers a paradigm shift in CAD management. Heretofore, radionuclide myocardial perfusion imaging has been primarily qualitative or at best semiquantitative in nature, assessing regional perfusion in relative terms. Thus, unlike so many facets of modern cardiovascular practice and CAD management, which depend, for example, on absolute values of key parameters such as arterial and left ventricular pressures, serum lipoprotein, and other biomarker levels, the absolute levels of rest and maximal myocardial blood flow have yet to be incorporated into routine clinical practice even in most positron emission tomography centers where the potential to do so exists. Accordingly, this review focuses on potential value added for improving clinical CAD practice by measuring the absolute level of rest and maximal myocardial blood flow. Physiological principles and imaging fundamentals necessary to understand how positron emission tomography makes robust, quantitative measurements of myocardial blood flow possible are highlighted. © 2016 American Heart Association, Inc.

  19. Quantitative color measurement of pH indicator paper using trichromatic LEDs and TCS230 color sensor

    NASA Astrophysics Data System (ADS)

    Ghorude, T. N.; Chaudhari, A. L.; Shaligram, A. D.

    2008-11-01

    Quantitative analysis of pH indicator paper color is needed in the various fields. An indigenously developed Tristimulus colorimeter is used in this work for pH Indicator paper color measurement. The colorimeter uses Trichromatic RGB LEDs and a programmable color light to frequency converter (TCS230), combining configurable silicon photodiodes and a current to frequency converter on a single monolithic CMOS integrated circuit. The output is a square wave (50% duty cycle) with frequency directly proportional to light intensity. Digital input and digital output allow directly to a microcontroller. The light to frequency converter reads an 8*8 array of photodiodes. Sixteen photodiodes have red filters, 16 photodiodes have green filters, 16 photodiodes have blue filters, and 16 photodiodes are clear with no filters. All 16 photodiodes of the same colors are connected in parallel and type of photodiode the device uses during operation is pin selectable. Solutions having different standard pH were prepared and indicator paper was dipped in solution, it shows change in color. Using the developed RGB colorimeter chromaticity coordinates were measured and compared with the chromaticity coordinates measured using Ocean Optics HR-4000 high resolution spectrophotometer.

  20. Methods for quantitative measurement of tooth wear using the area and volume of virtual model cusps.

    PubMed

    Kim, Soo-Hyun; Park, Young-Seok; Kim, Min-Kyoung; Kim, Sulhee; Lee, Seung-Pyo

    2018-04-01

    Clinicians must examine tooth wear to make a proper diagnosis. However, qualitative methods of measuring tooth wear have many disadvantages. Therefore, this study aimed to develop and evaluate quantitative parameters using the cusp area and volume of virtual dental models. The subjects of this study were the same virtual models that were used in our former study. The same age group classification and new tooth wear index (NTWI) scoring system were also reused. A virtual occlusal plane was generated with the highest cusp points and lowered vertically from 0.2 to 0.8 mm to create offset planes. The area and volume of each cusp was then measured and added together. In addition to the former analysis, the differential features of each cusp were analyzed. The scores of the new parameters differentiated the age and NTWI groups better than those analyzed in the former study. The Spearman ρ coefficients between the total area and the area of each cusp also showed higher scores at the levels of 0.6 mm (0.6A) and 0.8A. The mesiolingual cusp (MLC) showed a statistically significant difference ( P <0.01) from the other cusps in the paired t -test. Additionally, the MLC exhibited the highest percentage of change at 0.6A in some age and NTWI groups. Regarding the age groups, the MLC showed the highest score in groups 1 and 2. For the NTWI groups, the MLC was not significantly different in groups 3 and 4. These results support the proposal that the lingual cusp exhibits rapid wear because it serves as a functional cusp. Although this study has limitations due to its cross-sectional nature, it suggests better quantitative parameters and analytical tools for the characteristics of cusp wear.

  1. Methods for quantitative measurement of tooth wear using the area and volume of virtual model cusps

    PubMed Central

    2018-01-01

    Purpose Clinicians must examine tooth wear to make a proper diagnosis. However, qualitative methods of measuring tooth wear have many disadvantages. Therefore, this study aimed to develop and evaluate quantitative parameters using the cusp area and volume of virtual dental models. Methods The subjects of this study were the same virtual models that were used in our former study. The same age group classification and new tooth wear index (NTWI) scoring system were also reused. A virtual occlusal plane was generated with the highest cusp points and lowered vertically from 0.2 to 0.8 mm to create offset planes. The area and volume of each cusp was then measured and added together. In addition to the former analysis, the differential features of each cusp were analyzed. Results The scores of the new parameters differentiated the age and NTWI groups better than those analyzed in the former study. The Spearman ρ coefficients between the total area and the area of each cusp also showed higher scores at the levels of 0.6 mm (0.6A) and 0.8A. The mesiolingual cusp (MLC) showed a statistically significant difference (P<0.01) from the other cusps in the paired t-test. Additionally, the MLC exhibited the highest percentage of change at 0.6A in some age and NTWI groups. Regarding the age groups, the MLC showed the highest score in groups 1 and 2. For the NTWI groups, the MLC was not significantly different in groups 3 and 4. These results support the proposal that the lingual cusp exhibits rapid wear because it serves as a functional cusp. Conclusions Although this study has limitations due to its cross-sectional nature, it suggests better quantitative parameters and analytical tools for the characteristics of cusp wear. PMID:29770241

  2. Extracting quantitative measures from EAP: a small clinical study using BFOR.

    PubMed

    Hosseinbor, A Pasha; Chung, Moo K; Wu, Yu-Chien; Fleming, John O; Field, Aaron S; Alexander, Andrew L

    2012-01-01

    The ensemble average propagator (EAP) describes the 3D average diffusion process of water molecules, capturing both its radial and angular contents, and hence providing rich information about complex tissue microstructure properties. Bessel Fourier orientation reconstruction (BFOR) is one of several analytical, non-Cartesian EAP reconstruction schemes employing multiple shell acquisitions that have recently been proposed. Such modeling bases have not yet been fully exploited in the extraction of rotationally invariant q-space indices that describe the degree of diffusion anisotropy/restrictivity. Such quantitative measures include the zero-displacement probability (P(o)), mean squared displacement (MSD), q-space inverse variance (QIV), and generalized fractional anisotropy (GFA), and all are simply scalar features of the EAP. In this study, a general relationship between MSD and q-space diffusion signal is derived and an EAP-based definition of GFA is introduced. A significant part of the paper is dedicated to utilizing BFOR in a clinical dataset, comprised of 5 multiple sclerosis (MS) patients and 4 healthy controls, to estimate P(o), MSD, QIV, and GFA of corpus callosum, and specifically, to see if such indices can detect changes between normal appearing white matter (NAWM) and healthy white matter (WM). Although the sample size is small, this study is a proof of concept that can be extended to larger sample sizes in the future.

  3. Light scattering application for quantitative estimation of apoptosis

    NASA Astrophysics Data System (ADS)

    Bilyy, Rostyslav O.; Stoika, Rostyslav S.; Getman, Vasyl B.; Bilyi, Olexander I.

    2004-05-01

    Estimation of cell proliferation and apoptosis are in focus of instrumental methods used in modern biomedical sciences. Present study concerns monitoring of functional state of cells, specifically the development of their programmed death or apoptosis. The available methods for such purpose are either very expensive, or require time-consuming operations. Their specificity and sensitivity are frequently not sufficient for making conclusions which could be used in diagnostics or treatment monitoring. We propose a novel method for apoptosis measurement based on quantitative determination of cellular functional state taking into account their physical characteristics. This method uses the patented device -- laser microparticle analyser PRM-6 -- for analyzing light scattering by the microparticles, including cells. The method gives an opportunity for quick, quantitative, simple (without complicated preliminary cell processing) and relatively cheap measurement of apoptosis in cellular population. The elaborated method was used for studying apoptosis expression in murine leukemia cells of L1210 line and human lymphoblastic leukemia cells of K562 line. The results obtained by the proposed method permitted measuring cell number in tested sample, detecting and quantitative characterization of functional state of cells, particularly measuring the ratio of the apoptotic cells in suspension.

  4. DGT Passive Sampling for Quantitative in Situ Measurements of Compounds from Household and Personal Care Products in Waters.

    PubMed

    Chen, Wei; Li, Yanying; Chen, Chang-Er; Sweetman, Andrew J; Zhang, Hao; Jones, Kevin C

    2017-11-21

    Widespread use of organic chemicals in household and personal care products (HPCPs) and their discharge into aquatic systems means reliable, robust techniques to monitor environmental concentrations are needed. The passive sampling approach of diffusive gradients in thin-films (DGT) is developed here and demonstrated to provide in situ quantitative and time-weighted average (TWA) measurement of these chemicals in waters. The novel technique is developed for HPCPs, including preservatives, antioxidants and disinfectants, by evaluating the performance of different binding agents. Ultrasonic extraction of binding gels in acetonitrile gave good and consistent recoveries for all test chemicals. Uptake by DGT with HLB (hydrophilic-lipophilic-balanced) as the binding agent was relatively independent of pH (3.5-9.5), ionic strength (0.001-0.1 M) and dissolved organic matter (0-20 mg L -1 ), making it suitable for applications across a wide range of environments. Deployment time and diffusion layer thickness dependence experiments confirmed DGT accumulated chemicals masses are consistent with theoretical predictions. The technique was further tested and applied in the influent and effluent of a wastewater treatment plant. Results were compared with conventional grab-sampling and 24-h-composited samples from autosamplers. DGT provided TWA concentrations over up to 18 days deployment, with minimal effects from biofouling or the diffusive boundary layer. The field application demonstrated advantages of the DGT technique: it gives in situ analyte preconcentration in a simple matrix, with more quantitative measurement of the HPCP analytes.

  5. Accuracy of quantitative visual soil assessment

    NASA Astrophysics Data System (ADS)

    van Leeuwen, Maricke; Heuvelink, Gerard; Stoorvogel, Jetse; Wallinga, Jakob; de Boer, Imke; van Dam, Jos; van Essen, Everhard; Moolenaar, Simon; Verhoeven, Frank; Stoof, Cathelijne

    2016-04-01

    Visual soil assessment (VSA) is a method to assess soil quality visually, when standing in the field. VSA is increasingly used by farmers, farm organisations and companies, because it is rapid and cost-effective, and because looking at soil provides understanding about soil functioning. Often VSA is regarded as subjective, so there is a need to verify VSA. Also, many VSAs have not been fine-tuned for contrasting soil types. This could lead to wrong interpretation of soil quality and soil functioning when contrasting sites are compared to each other. We wanted to assess accuracy of VSA, while taking into account soil type. The first objective was to test whether quantitative visual field observations, which form the basis in many VSAs, could be validated with standardized field or laboratory measurements. The second objective was to assess whether quantitative visual field observations are reproducible, when used by observers with contrasting backgrounds. For the validation study, we made quantitative visual observations at 26 cattle farms. Farms were located at sand, clay and peat soils in the North Friesian Woodlands, the Netherlands. Quantitative visual observations evaluated were grass cover, number of biopores, number of roots, soil colour, soil structure, number of earthworms, number of gley mottles and soil compaction. Linear regression analysis showed that four out of eight quantitative visual observations could be well validated with standardized field or laboratory measurements. The following quantitative visual observations correlated well with standardized field or laboratory measurements: grass cover with classified images of surface cover; number of roots with root dry weight; amount of large structure elements with mean weight diameter; and soil colour with soil organic matter content. Correlation coefficients were greater than 0.3, from which half of the correlations were significant. For the reproducibility study, a group of 9 soil scientists and 7

  6. A simple method for the evaluation of microfluidic architecture using flow quantitation via a multiplexed fluidic resistance measurement.

    PubMed

    Leslie, Daniel C; Melnikoff, Brett A; Marchiarullo, Daniel J; Cash, Devin R; Ferrance, Jerome P; Landers, James P

    2010-08-07

    Quality control of microdevices adds significant costs, in time and money, to any fabrication process. A simple, rapid quantitative method for the post-fabrication characterization of microchannel architecture using the measurement of flow with volumes relevant to microfluidics is presented. By measuring the mass of a dye solution passed through the device, it circumvents traditional gravimetric and interface-tracking methods that suffer from variable evaporation rates and the increased error associated with smaller volumes. The multiplexed fluidic resistance (MFR) measurement method measures flow via stable visible-wavelength dyes, a standard spectrophotometer and common laboratory glassware. Individual dyes are used as molecular markers of flow for individual channels, and in channel architectures where multiple channels terminate at a common reservoir, spectral deconvolution reveals the individual flow contributions. On-chip, this method was found to maintain accurate flow measurement at lower flow rates than the gravimetric approach. Multiple dyes are shown to allow for independent measurement of multiple flows on the same device simultaneously. We demonstrate that this technique is applicable for measuring the fluidic resistance, which is dependent on channel dimensions, in four fluidically connected channels simultaneously, ultimately determining that one chip was partially collapsed and, therefore, unusable for its intended purpose. This method is thus shown to be widely useful in troubleshooting microfluidic flow characteristics.

  7. FAIR exempting separate T (1) measurement (FAIREST): a novel technique for online quantitative perfusion imaging and multi-contrast fMRI.

    PubMed

    Lai, S; Wang, J; Jahng, G H

    2001-01-01

    A new pulse sequence, dubbed FAIR exempting separate T(1) measurement (FAIREST) in which a slice-selective saturation recovery acquisition is added in addition to the standard FAIR (flow-sensitive alternating inversion recovery) scheme, was developed for quantitative perfusion imaging and multi-contrast fMRI. The technique allows for clean separation between and thus simultaneous assessment of BOLD and perfusion effects, whereas quantitative cerebral blood flow (CBF) and tissue T(1) values are monitored online. Online CBF maps were obtained using the FAIREST technique and the measured CBF values were consistent with the off-line CBF maps obtained from using the FAIR technique in combination with a separate sequence for T(1) measurement. Finger tapping activation studies were carried out to demonstrate the applicability of the FAIREST technique in a typical fMRI setting for multi-contrast fMRI. The relative CBF and BOLD changes induced by finger-tapping were 75.1 +/- 18.3 and 1.8 +/- 0.4%, respectively, and the relative oxygen consumption rate change was 2.5 +/- 7.7%. The results from correlation of the T(1) maps with the activation images on a pixel-by-pixel basis show that the mean T(1) value of the CBF activation pixels is close to the T(1) of gray matter while the mean T(1) value of the BOLD activation pixels is close to the T(1) range of blood and cerebrospinal fluid. Copyright 2001 John Wiley & Sons, Ltd.

  8. Quantitative measurement of salivary testosterone in Korean adults by stable isotope-dilution liquid chromatographyelectrospray-tandem mass spectrometry.

    PubMed

    Lee, Sanghoo; Kwon, Soonho; Shin, Hye-Jin; Park, Jimyeong; Lim, Hwan-Sub; Lee, Kyoung-Ryul; Kim, Young-Jin

    2010-11-01

    Salivary testosterone levels in Korean adults were quantitatively measured for the first time by liquid chromatography-electrospray-tandem mass spectrometry (LC ESI MS/MS). Salivary testosterone was separated on a multiple reaction monitoring (MRM) chromatogram within 7 min. The LC ESI MS/MS assay was validated over the linearity range of 0.01-2.00 ng/ml (r=0.99987) using testosterone-d(3) as an internal standard. The lower limit of quantification (LOQ) was 0.01 ng/ml. The intra- and inter-assay precisions were 1.54% to 4.09% and 0.96% to 4.29%, respectively. The mean recovery was 93.32% (range 88.43-98.05%). The validated assay was then applied to measure the salivary testosterone levels of Korean adults. In men, the salivary testosterone level collected between 9:00-11:00 am was approximately 2.8 times higher than that in women (P < 0.0001). Salivary testosterone levels in both sexes negatively correlated with age. The present assay would also be useful in measuring salivary testosterone levels in clinical laboratories.

  9. Quantitative measurement of cerebral blood flow in a juvenile porcine model by depth-resolved near-infrared spectroscopy

    NASA Astrophysics Data System (ADS)

    Elliott, Jonathan T.; Diop, Mamadou; Tichauer, Kenneth M.; Lee, Ting-Yim; Lawrence, Keith St.

    2010-05-01

    Nearly half a million children and young adults are affected by traumatic brain injury each year in the United States. Although adequate cerebral blood flow (CBF) is essential to recovery, complications that disrupt blood flow to the brain and exacerbate neurological injury often go undetected because no adequate bedside measure of CBF exists. In this study we validate a depth-resolved, near-infrared spectroscopy (NIRS) technique that provides quantitative CBF measurement despite significant signal contamination from skull and scalp tissue. The respiration rates of eight anesthetized pigs (weight: 16.2+/-0.5 kg, age: 1 to 2 months old) are modulated to achieve a range of CBF levels. Concomitant CBF measurements are performed with NIRS and CT perfusion. A significant correlation between CBF measurements from the two techniques is demonstrated (r2=0.714, slope=0.92, p<0.001), and the bias between the two techniques is -2.83 mL.min-1.100 g-1 (CI0.95: -19.63 mL.min-1.100 g-1-13.9 mL.min-1.100 g-1). This study demonstrates that accurate measurements of CBF can be achieved with depth-resolved NIRS despite significant signal contamination from scalp and skull. The ability to measure CBF at the bedside provides a means of detecting, and thereby preventing, secondary ischemia during neurointensive care.

  10. Development of a Biological Science Quantitative Reasoning Exam (BioSQuaRE)

    ERIC Educational Resources Information Center

    Stanhope, Liz; Ziegler, Laura; Haque, Tabassum; Le, Laura; Vinces, Marcelo; Davis, Gregory K.; Zieffler, Andrew; Brodfuehrer, Peter; Preest, Marion; Belitsky, Jason M.; Umbanhowar, Charles, Jr.; Overvoorde, Paul J.

    2017-01-01

    Multiple reports highlight the increasingly quantitative nature of biological research and the need to innovate means to ensure that students acquire quantitative skills. We present a tool to support such innovation. The Biological Science Quantitative Reasoning Exam (BioSQuaRE) is an assessment instrument designed to measure the quantitative…

  11. On-Chip Quantitative Measurement of Mechanical Stresses During Cell Migration with Emulsion Droplets

    NASA Astrophysics Data System (ADS)

    Molino, D.; Quignard, S.; Gruget, C.; Pincet, F.; Chen, Y.; Piel, M.; Fattaccioli, J.

    2016-07-01

    The ability of immune cells to migrate within narrow and crowded spaces is a critical feature involved in various physiological processes from immune response to metastasis. Several in-vitro techniques have been developed so far to study the behaviour of migrating cells, the most recent being based on the fabrication of microchannels within which cells move. To address the question of the mechanical stress a cell is able to produce during the encounter of an obstacle while migrating, we developed a hybrid microchip made of parallel PDMS channels in which oil droplets are sparsely distributed and serve as deformable obstacles. We thus show that cells strongly deform droplets while passing them. Then, we show that the microdevice can be used to study the influence of drugs on migration at the population level. Finally, we describe a quantitative analysis method of the droplet deformation that allows measuring in real-time the mechanical stress exerted by a single cell. The method presented herein thus constitutes a powerful analytical tool for cell migration studies under confinement.

  12. Polarbrdf: A General Purpose Python Package for Visualization Quantitative Analysis of Multi-Angular Remote Sensing Measurements

    NASA Technical Reports Server (NTRS)

    Singh, Manoj K.; Gautam, Ritesh; Gatebe, Charles K.; Poudyal, Rajesh

    2016-01-01

    The Bidirectional Reflectance Distribution Function (BRDF) is a fundamental concept for characterizing the reflectance property of a surface, and helps in the analysis of remote sensing data from satellite, airborne and surface platforms. Multi-angular remote sensing measurements are required for the development and evaluation of BRDF models for improved characterization of surface properties. However, multi-angular data and the associated BRDF models are typically multidimensional involving multi-angular and multi-wavelength information. Effective visualization of such complex multidimensional measurements for different wavelength combinations is presently somewhat lacking in the literature, and could serve as a potentially useful research and teaching tool in aiding both interpretation and analysis of BRDF measurements. This article describes a newly developed software package in Python (PolarBRDF) to help visualize and analyze multi-angular data in polar and False Color Composite (FCC) forms. PolarBRDF also includes functionalities for computing important multi-angular reflectance/albedo parameters including spectral albedo, principal plane reflectance and spectral reflectance slope. Application of PolarBRDF is demonstrated using various case studies obtained from airborne multi-angular remote sensing measurements using NASA's Cloud Absorption Radiometer (CAR). Our visualization program also provides functionalities for untangling complex surface/atmosphere features embedded in pixel-based remote sensing measurements, such as the FCC imagery generation of BRDF measurements of grasslands in the presence of wild fire smoke and clouds. Furthermore, PolarBRDF also provides quantitative information of the angular distribution of scattered surface/atmosphere radiation, in the form of relevant BRDF variables such as sunglint, hotspot and scattering statistics.

  13. Influence of region-of-interest designs on quantitative measurement of multimodal imaging of MR non-enhancing gliomas.

    PubMed

    Takano, Koji; Kinoshita, Manabu; Arita, Hideyuki; Okita, Yoshiko; Chiba, Yasuyoshi; Kagawa, Naoki; Watanabe, Yoshiyuki; Shimosegawa, Eku; Hatazawa, Jun; Hashimoto, Naoya; Fujimoto, Yasunori; Kishima, Haruhiko

    2018-05-01

    A number of studies have revealed the usefulness of multimodal imaging in gliomas. Although the results have been heavily affected by the method used for region of interest (ROI) design, the most discriminatory method for setting the ROI remains unclear. The aim of the present study was to determine the most suitable ROI design for 18 F-fluorodeoxyglucose (FDG) and 11 C-methionine (MET) positron emission tomography (PET), apparent diffusion coefficient (ADC), and fractional anisotropy (FA) obtained by diffusion tensor imaging (DTI) from the viewpoint of grades of non-enhancing gliomas. A total of 31 consecutive patients with newly diagnosed, histologically confirmed magnetic resonance (MR) non-enhancing gliomas who underwent FDG-PET, MET-PET and DTI were retrospectively investigated. Quantitative measurements were performed using four different ROIs; hotspot/tumor center and whole tumor, constructed in either two-dimensional (2D) or three-dimensional (3D). Histopathological grading of the tumor was considered as empirical truth and the quantitative measurements obtained from each ROI was correlated with the grade of the tumor. The most discriminating ROI for non-enhancing glioma grading was different according to the different imaging modalities. 2D-hotspot/center ROI was most discriminating for FDG-PET (P=0.087), ADC map (P=0.0083), and FA map (P=0.25), whereas 3D-whole tumor ROI was best for MET-PET (P=0.0050). In the majority of scenarios, 2D-ROIs performed better than 3D-ROIs. Results from the image analysis using FDG-PET, MET-PET, ADC and FA may be affected by ROI design and the most discriminating ROI for non-enhancing glioma grading was different according to the imaging modality.

  14. Quantitative Characterization of Nanostructured Materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dr. Frank

    The two-and-a-half day symposium on the "Quantitative Characterization of Nanostructured Materials" will be the first comprehensive meeting on this topic held under the auspices of a major U.S. professional society. Spring MRS Meetings provide a natural venue for this symposium as they attract a broad audience of researchers that represents a cross-section of the state-of-the-art regarding synthesis, structure-property relations, and applications of nanostructured materials. Close interactions among the experts in local structure measurements and materials researchers will help both to identify measurement needs pertinent to real-world materials problems and to familiarize the materials research community with the state-of-the-art local structuremore » measurement techniques. We have chosen invited speakers that reflect the multidisciplinary and international nature of this topic and the need to continually nurture productive interfaces among university, government and industrial laboratories. The intent of the symposium is to provide an interdisciplinary forum for discussion and exchange of ideas on the recent progress in quantitative characterization of structural order in nanomaterials using different experimental techniques and theory. The symposium is expected to facilitate discussions on optimal approaches for determining atomic structure at the nanoscale using combined inputs from multiple measurement techniques.« less

  15. Towards a Quantitative Performance Measurement Framework to Assess the Impact of Geographic Information Standards

    NASA Astrophysics Data System (ADS)

    Vandenbroucke, D.; Van Orshoven, J.; Vancauwenberghe, G.

    2012-12-01

    Over the last decennia, the use of Geographic Information (GI) has gained importance, in public as well as in private sector. But even if many spatial data and related information exist, data sets are scattered over many organizations and departments. In practice it remains difficult to find the spatial data sets needed, and to access, obtain and prepare them for using in applications. Therefore Spatial Data Infrastructures (SDI) haven been developed to enhance the access, the use and sharing of GI. SDIs consist of a set of technological and non-technological components to reach this goal. Since the nineties many SDI initiatives saw light. Ultimately, all these initiatives aim to enhance the flow of spatial data between organizations (users as well as producers) involved in intra- and inter-organizational and even cross-country business processes. However, the flow of information and its re-use in different business processes requires technical and semantic interoperability: the first should guarantee that system components can interoperate and use the data, while the second should guarantee that data content is understood by all users in the same way. GI-standards within the SDI are necessary to make this happen. However, it is not known if this is realized in practice. Therefore the objective of the research is to develop a quantitative framework to assess the impact of GI-standards on the performance of business processes. For that purpose, indicators are defined and tested in several cases throughout Europe. The proposed research will build upon previous work carried out in the SPATIALIST project. It analyzed the impact of different technological and non-technological factors on the SDI-performance of business processes (Dessers et al., 2011). The current research aims to apply quantitative performance measurement techniques - which are frequently used to measure performance of production processes (Anupindi et al., 2005). Key to reach the research objectives

  16. Quantitative Articles: Developing Studies for Publication in Counseling Journals

    ERIC Educational Resources Information Center

    Trusty, Jerry

    2011-01-01

    This article is presented as a guide for developing quantitative studies and preparing quantitative manuscripts for publication in counseling journals. It is intended as an aid for aspiring authors in conceptualizing studies and formulating valid research designs. Material is presented on choosing variables and measures and on selecting…

  17. The Vermicelli Handling Test: A Simple Quantitative Measure of Dexterous Forepaw Function in Rats

    PubMed Central

    Allred, Rachel P.; Adkins, DeAnna L.; Woodlee, Martin T.; Husbands, Lincoln C.; Maldonado, Mónica A.; Kane, Jacqueline R.; Schallert, Timothy; Jones, Theresa A.

    2008-01-01

    Loss of function in the hands occurs with many brain disorders, but there are few measures of skillful forepaw use in rats available to model these impairments that are both sensitive and simple to administer. Whishaw and Coles (1996) previously described the dexterous manner in which rats manipulate food items with their paws, including thin pieces of pasta. We set out to develop a measure of this food handling behavior that would be quantitative, easy to administer, sensitive to the effects of damage to sensory and motor systems of the CNS and useful for identifying the side of lateralized impairments. When rats handle 7 cm lengths of vermicelli, they manipulate the pasta by repeatedly adjusting the forepaw hold on the pasta piece. As operationally defined, these adjustments can be easily identified and counted by an experimenter without specialized equipment. After unilateral sensorimotor cortex (SMC) lesions, transient middle cerebral artery occlusion (MCAO) and striatal dopamine depleting (6-hydroxydopamine, 6-OHDA) lesions in adult rats, there were enduring reductions in adjustments made with the contralateral forepaw. Additional pasta handling characteristics distinguished between the lesion types. MCAO and 6-OHDA lesions increased the frequency of several identified atypical handling patterns. Severe dopamine depletion increased eating time and adjustments made with the ipsilateral forepaw. However, contralateral forepaw adjustment number most sensitively detected enduring impairments across lesion types. Because of its ease of administration and sensitivity to lateralized impairments in skilled forepaw use, this measure may be useful in rat models of upper extremity impairment. PMID:18325597

  18. Quantitative measurement of binary liquid distributions using multiple-tracer x-ray fluorescence and radiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Halls, Benjamin R.; Meyer, Terrence R.; Kastengren, Alan L.

    2015-01-01

    The complex geometry and large index-of-refraction gradients that occur near the point of impingement of binary liquid jets present a challenging environment for optical interrogation. A simultaneous quadruple-tracer x-ray fluorescence and line-of-sight radiography technique is proposed as a means of distinguishing and quantifying individual liquid component distributions prior to, during, and after jet impact. Two different pairs of fluorescence tracers are seeded into each liquid stream to maximize their attenuation ratio for reabsorption correction and differentiation of the two fluids during mixing. This approach for instantaneous correction of x-ray fluorescence reabsorption is compared with a more time-intensive approach of usingmore » stereographic reconstruction of x-ray attenuation along multiple lines of sight. The proposed methodology addresses the need for a quantitative measurement technique capable of interrogating optically complex, near-field liquid distributions in many mixing systems of practical interest involving two or more liquid streams.« less

  19. Quantitative fluorescence measurements performed on typical matrix molecules in matrix-assisted laser desorption/ionisation

    NASA Astrophysics Data System (ADS)

    Allwood, D. A.; Dyer, P. E.

    2000-11-01

    Fundamental photophysical parameters have been determined for several molecules that are commonly used as matrices, e.g. ferulic acid, within matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. Fluorescence quantum efficiencies ( φqe), singlet decay rates ( kl), vibrationless ground-singlet transition energies and average fluorescence wavelengths have been obtained from solid and solution samples by quantitative optical measurements. This new data will assist in modelling calculations of MALDI processes and in highlighting desirable characteristics of MALDI matrices. φqe may be as high as 0.59 whilst the radiative decay rate ( kf) appears to be within the (0.8-4)×10 8 s -1 range. Interestingly, α-cyano-4-hydroxycinnamic acid (α-CHC) has a very low φqe and fast non-radiative decay rate which would imply a rapid and efficient thermalisation of electronic excitation. This is in keeping with observations that α-CHC exhibits low threshold fluences for ion detection and the low fluences at which α-CHC tends to fragment.

  20. Quantitative measurement of binary liquid distributions using multiple-tracer x-ray fluorescence and radiography

    DOE PAGES

    Halls, Benjamin R.; Meyer, Terrence R.; Kastengren, Alan L.

    2015-01-23

    The complex geometry and large index-of-refraction gradients that occur near the point of impingement of binary liquid jets present a challenging environment for optical interrogation. A simultaneous quadruple-tracer x-ray fluorescence and line-of-sight radiography technique is proposed as a means of distinguishing and quantifying individual liquid component distributions prior to, during, and after jet impact. Two different pairs of fluorescence tracers are seeded into each liquid stream to maximize their attenuation ratio for reabsorption correction and differentiation of the two fluids during mixing. This approach for instantaneous correction of x-ray fluorescence reabsorption is compared with a more time-intensive approach of usingmore » stereographic reconstruction of x-ray attenuation along multiple lines of sight. The proposed methodology addresses the need for a quantitative measurement technique capable of interrogating optically complex, near-field liquid distributions in many mixing systems of practical interest involving two or more liquid streams.« less

  1. Studying learning in the healthcare setting: the potential of quantitative diary methods.

    PubMed

    Ciere, Yvette; Jaarsma, Debbie; Visser, Annemieke; Sanderman, Robbert; Snippe, Evelien; Fleer, Joke

    2015-08-01

    Quantitative diary methods are longitudinal approaches that involve the repeated measurement of aspects of peoples' experience of daily life. In this article, we outline the main characteristics and applications of quantitative diary methods and discuss how their use may further research in the field of medical education. Quantitative diary methods offer several methodological advantages, such as measuring aspects of learning with great detail, accuracy and authenticity. Moreover, they enable researchers to study how and under which conditions learning in the health care setting occurs and in which way learning can be promoted. Hence, quantitative diary methods may contribute to theory development and the optimization of teaching methods in medical education.

  2. A comparison of manual and quantitative elbow strength testing.

    PubMed

    Shahgholi, Leili; Bengtson, Keith A; Bishop, Allen T; Shin, Alexander Y; Spinner, Robert J; Basford, Jeffrey R; Kaufman, Kenton R

    2012-10-01

    The aim of this study was to compare the clinical ratings of elbow strength obtained by skilled clinicians with objective strength measurement obtained through quantitative testing. A retrospective comparison of subject clinical records with quantitative strength testing results in a motion analysis laboratory was conducted. A total of 110 individuals between the ages of 8 and 65 yrs with traumatic brachial plexus injuries were identified. Patients underwent manual muscle strength testing as assessed on the 5-point British Medical Research Council Scale (5/5, normal; 0/5, absent) and quantitative elbow flexion and extension strength measurements. A total of 92 subjects had elbow flexion testing. Half of the subjects clinically assessed as having normal (5/5) elbow flexion strength on manual muscle testing exhibited less than 42% of their age-expected strength on quantitative testing. Eighty-four subjects had elbow extension strength testing. Similarly, half of those displaying normal elbow extension strength on manual muscle testing were found to have less than 62% of their age-expected values on quantitative testing. Significant differences between manual muscle testing and quantitative findings were not detected for the lesser (0-4) strength grades. Manual muscle testing, even when performed by experienced clinicians, may be more misleading than expected for subjects graded as having normal (5/5) strength. Manual muscle testing estimates for the lesser strength grades (1-4/5) seem reasonably accurate.

  3. Quantitative measurement of the chemical composition of geological standards with a miniature laser ablation/ionization mass spectrometer designed for in situ application in space research

    NASA Astrophysics Data System (ADS)

    Neuland, M. B.; Grimaudo, V.; Mezger, K.; Moreno-García, P.; Riedo, A.; Tulej, M.; Wurz, P.

    2016-03-01

    A key interest of planetary space missions is the quantitative determination of the chemical composition of the planetary surface material. The chemical composition of surface material (minerals, rocks, soils) yields fundamental information that can be used to answer key scientific questions about the formation and evolution of the planetary body in particular and the Solar System in general. We present a miniature time-of-flight type laser ablation/ionization mass spectrometer (LMS) and demonstrate its capability in measuring the elemental and mineralogical composition of planetary surface samples quantitatively by using a femtosecond laser for ablation/ionization. The small size and weight of the LMS make it a remarkable tool for in situ chemical composition measurements in space research, convenient for operation on a lander or rover exploring a planetary surface. In the laboratory, we measured the chemical composition of four geological standard reference samples USGS AGV-2 Andesite, USGS SCo-l Cody Shale, NIST 97b Flint Clay and USGS QLO-1 Quartz Latite with LMS. These standard samples are used to determine the sensitivity factors of the instrument. One important result is that all sensitivity factors are close to 1. Additionally, it is observed that the sensitivity factor of an element depends on its electron configuration, hence on the electron work function and the elemental group in agreement with existing theory. Furthermore, the conformity of the sensitivity factors is supported by mineralogical analyses of the USGS SCo-l and the NIST 97b samples. With the four different reference samples, the consistency of the calibration factors can be demonstrated, which constitutes the fundamental basis for a standard-less measurement-technique for in situ quantitative chemical composition measurements on planetary surface.

  4. Semi-automated quantitative Drosophila wings measurements.

    PubMed

    Loh, Sheng Yang Michael; Ogawa, Yoshitaka; Kawana, Sara; Tamura, Koichiro; Lee, Hwee Kuan

    2017-06-28

    Drosophila melanogaster is an important organism used in many fields of biological research such as genetics and developmental biology. Drosophila wings have been widely used to study the genetics of development, morphometrics and evolution. Therefore there is much interest in quantifying wing structures of Drosophila. Advancement in technology has increased the ease in which images of Drosophila can be acquired. However such studies have been limited by the slow and tedious process of acquiring phenotypic data. We have developed a system that automatically detects and measures key points and vein segments on a Drosophila wing. Key points are detected by performing image transformations and template matching on Drosophila wing images while vein segments are detected using an Active Contour algorithm. The accuracy of our key point detection was compared against key point annotations of users. We also performed key point detection using different training data sets of Drosophila wing images. We compared our software with an existing automated image analysis system for Drosophila wings and showed that our system performs better than the state of the art. Vein segments were manually measured and compared against the measurements obtained from our system. Our system was able to detect specific key points and vein segments from Drosophila wing images with high accuracy.

  5. A theoretical/experimental program to develop active optical pollution sensors: Quantitative remote Raman lidar measurements of pollutants from stationary sources

    NASA Technical Reports Server (NTRS)

    Poultney, S. K.; Brumfield, M. L.; Siviter, J. S.

    1975-01-01

    Typical pollutant gas concentrations at the stack exits of stationary sources can be estimated to be about 500 ppm under the present emission standards. Raman lidar has a number of advantages which makes it a valuable tool for remote measurements of these stack emissions. Tests of the Langley Research Center Raman lidar at a calibration tank indicate that night measurements of SO2 concentrations and stack opacity are possible. Accuracies of 10 percent are shown to be achievable from a distance of 300 m within 30 min integration times for 500 ppm SO2 at the stack exits. All possible interferences were examined quantitatively (except for the fluorescence of aerosols in actual stack emissions) and found to have negligible effect on the measurements. An early test at an instrumented stack is strongly recommended.

  6. Quantitative measurement of airborne cockroach allergen in New York City apartments

    PubMed Central

    Esposito, W. A.; Chew, G. L.; Correa, J. C.; Chillrud, S. N.; Miller, R. L.; Kinney, P. L.

    2013-01-01

    We designed and tested a sampling and analysis system for quantitative measurement of airborne cockroach allergen with sufficient sensitivity for residential exposure assessment. Integrated 1-week airborne particle samples were collected at 10–15 LPM in 19 New York City apartments in which an asthmatic child who was allergic to cockroach allergen resided. Four simultaneous air samples were collected in each home: at heights of 0.3 and 1 m in the child's bedroom and in the kitchen. Extracts of air samples were analyzed by ELISA for the cockroach allergen Bla g2, modified by amplifying the colorimetric signal generated via use of AMPLI-Q detection system (DAKO Corporation, Carpinteria, CA, USA). Settled dust samples were quantified by conventional ELISA. Of the homes where cockroach allergen was detected in settled dust, Bla g2 also was detected in 87% and 93% of air samples in the bedroom and kitchen, respectively. Airborne Bla g2 levels were highly correlated within and between the bedroom and kitchen locations (P < 0.001). Expressed as picogram per cubic meter, the room average geometric mean for Bla g2 concentrations was 1.9 pg/m3 (95% CI 0.63, 4.57) and 3.8 pg/m3 (95% CI 1.35, 9.25) in bedrooms and kitchens, respectively. This method offers an attractive supplement to settled dust sampling for cockroach allergen exposure health studies. PMID:21658130

  7. In situ hybridization of oxytocin messenger RNA: macroscopic distribution and quantitation in rat hypothalamic cell groups

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burbach, J.P.; Voorhuis, T.A.; van Tol, H.H.

    1987-05-29

    Oxytocin mRNA was detected in the rat hypothalamus by in situ hybridization to a single stranded /sup 35/S-labelled DNA probe and the distribution of oxytocin mRNA-containing cell groups was studied at the macroscopic level. Specificity of hybridization was confirmed by comparison to vasopressin mRNA hybridization in parallel tissue sections. Cell groups containing oxytocin mRNA were confined to a set of hypothalamic cell groups, i.c. the supraoptic, paraventricular, anterior commissural nuclei, nucleus circularis and scattered hypothalamic islets. These cell groups displayed similar densities of autoradiographic signals indicating that the oxytocin gene is expressed at approximately the same average level at thesemore » various sites.« less

  8. Guidelines for improving the reproducibility of quantitative multiparameter immunofluorescence measurements by laser scanning cytometry on fixed cell suspensions from human solid tumors.

    PubMed

    Shackney, Stanley; Emlet, David R; Pollice, Agnese; Smith, Charles; Brown, Kathryn; Kociban, Deborah

    2006-01-01

    Laser scanning Cytometry (LSC) is a versatile technology that makes it possible to perform multiple measurements on individual cells and correlate them cell by cell with other cellular features. It would be highly desirable to be able to perform reproducible, quantitative, correlated cell-based immunofluorescence studies on individual cells from human solid tumors. However, such studies can be challenging because of the presence of large numbers of cell aggregates and other confounding factors. Techniques have been developed to deal with cell aggregates in data sets collected by LSC. Experience has also been gained in addressing other key technical and methodological issues that can affect the reproducibility of such cell-based immunofluorescence measurements. We describe practical aspects of cell sample collection, cell fixation and staining, protocols for performing multiparameter immunofluorescence measurements by LSC, use of controls and reference samples, and approaches to data analysis that we have found useful in improving the accuracy and reproducibility of LSC data obtained in human tumor samples. We provide examples of the potential advantages of LSC in examining quantitative aspects of cell-based analysis. Improvements in the quality of cell-based multiparameter immunofluorescence measurements make it possible to extract useful information from relatively small numbers of cells. This, in turn, permits the performance of multiple multicolor panels on each tumor sample. With links among the different panels that are provided by overlapping measurements, it is possible to develop increasingly more extensive profiles of intracellular expression of multiple proteins in clinical samples of human solid tumors. Examples of such linked panels of measurements are provided. Advances in methodology can improve cell-based multiparameter immunofluorescence measurements on cell suspensions from human solid tumors by LSC for use in prognostic and predictive clinical

  9. Construction of measurement uncertainty profiles for quantitative analysis of genetically modified organisms based on interlaboratory validation data.

    PubMed

    Macarthur, Roy; Feinberg, Max; Bertheau, Yves

    2010-01-01

    A method is presented for estimating the size of uncertainty associated with the measurement of products derived from genetically modified organisms (GMOs). The method is based on the uncertainty profile, which is an extension, for the estimation of uncertainty, of a recent graphical statistical tool called an accuracy profile that was developed for the validation of quantitative analytical methods. The application of uncertainty profiles as an aid to decision making and assessment of fitness for purpose is also presented. Results of the measurement of the quantity of GMOs in flour by PCR-based methods collected through a number of interlaboratory studies followed the log-normal distribution. Uncertainty profiles built using the results generally give an expected range for measurement results of 50-200% of reference concentrations for materials that contain at least 1% GMO. This range is consistent with European Network of GM Laboratories and the European Union (EU) Community Reference Laboratory validation criteria and can be used as a fitness for purpose criterion for measurement methods. The effect on the enforcement of EU labeling regulations is that, in general, an individual analytical result needs to be < 0.45% to demonstrate compliance, and > 1.8% to demonstrate noncompliance with a labeling threshold of 0.9%.

  10. Quantitative Muscle Ultrasonography in Carpal Tunnel Syndrome.

    PubMed

    Lee, Hyewon; Jee, Sungju; Park, Soo Ho; Ahn, Seung-Chan; Im, Juneho; Sohn, Min Kyun

    2016-12-01

    To assess the reliability of quantitative muscle ultrasonography (US) in healthy subjects and to evaluate the correlation between quantitative muscle US findings and electrodiagnostic study results in patients with carpal tunnel syndrome (CTS). The clinical significance of quantitative muscle US in CTS was also assessed. Twenty patients with CTS and 20 age-matched healthy volunteers were recruited. All control and CTS subjects underwent a bilateral median and ulnar nerve conduction study (NCS) and quantitative muscle US. Transverse US images of the abductor pollicis brevis (APB) and abductor digiti minimi (ADM) were obtained to measure muscle cross-sectional area (CSA), thickness, and echo intensity (EI). EI was determined using computer-assisted, grayscale analysis. Inter-rater and intra-rater reliability for quantitative muscle US in control subjects, and differences in muscle thickness, CSA, and EI between the CTS patient and control groups were analyzed. Relationships between quantitative US parameters and electrodiagnostic study results were evaluated. Quantitative muscle US had high inter-rater and intra-rater reliability in the control group. Muscle thickness and CSA were significantly decreased, and EI was significantly increased in the APB of the CTS group (all p<0.05). EI demonstrated a significant positive correlation with latency of the median motor and sensory NCS in CTS patients (p<0.05). These findings suggest that quantitative muscle US parameters may be useful for detecting muscle changes in CTS. Further study involving patients with other neuromuscular diseases is needed to evaluate peripheral muscle change using quantitative muscle US.

  11. Quantitative magnetic resonance imaging phantoms: A review and the need for a system phantom.

    PubMed

    Keenan, Kathryn E; Ainslie, Maureen; Barker, Alex J; Boss, Michael A; Cecil, Kim M; Charles, Cecil; Chenevert, Thomas L; Clarke, Larry; Evelhoch, Jeffrey L; Finn, Paul; Gembris, Daniel; Gunter, Jeffrey L; Hill, Derek L G; Jack, Clifford R; Jackson, Edward F; Liu, Guoying; Russek, Stephen E; Sharma, Samir D; Steckner, Michael; Stupic, Karl F; Trzasko, Joshua D; Yuan, Chun; Zheng, Jie

    2018-01-01

    The MRI community is using quantitative mapping techniques to complement qualitative imaging. For quantitative imaging to reach its full potential, it is necessary to analyze measurements across systems and longitudinally. Clinical use of quantitative imaging can be facilitated through adoption and use of a standard system phantom, a calibration/standard reference object, to assess the performance of an MRI machine. The International Society of Magnetic Resonance in Medicine AdHoc Committee on Standards for Quantitative Magnetic Resonance was established in February 2007 to facilitate the expansion of MRI as a mainstream modality for multi-institutional measurements, including, among other things, multicenter trials. The goal of the Standards for Quantitative Magnetic Resonance committee was to provide a framework to ensure that quantitative measures derived from MR data are comparable over time, between subjects, between sites, and between vendors. This paper, written by members of the Standards for Quantitative Magnetic Resonance committee, reviews standardization attempts and then details the need, requirements, and implementation plan for a standard system phantom for quantitative MRI. In addition, application-specific phantoms and implementation of quantitative MRI are reviewed. Magn Reson Med 79:48-61, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  12. Quantitative genetics

    USDA-ARS?s Scientific Manuscript database

    The majority of economically important traits targeted for cotton improvement are quantitatively inherited. In this chapter, the current state of cotton quantitative genetics is described and separated into four components. These components include: 1) traditional quantitative inheritance analysis, ...

  13. Quantitative Digital Autoradiography for Environmental Swipe Sample Prioritization: System design, Characterization, and Initial Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McDonald, Benjamin S.; Zalavadia, Mital A.; Miller, Brian W.

    Environmental sampling and sample analyses by the International Atomic Energy Agency’s (IAEA) Network of Analytical Laboratories (NWAL) is a critical technical tool used to detect facility misuse under a Comprehensive Safeguards Agreement and to verify the absence of undeclared nuclear material activities under an Additional Protocol. Currently all environmental swipe samples (ESS) are screened using gamma spectrometry and x-ray fluorescence to estimate the amount of U and/or Pu in the ESS, to guide further analysis, and to assist in the shipment of ESS to the NWAL. Quantitative Digital Autoradiography for Environmental Samples (QDARES) is being developed to complement existing techniquesmore » through the use of a portable, real-time, high-spatial-resolution camera called the Ionizing-radiation Quantum Imaging Detector (iQID). The iQID constructs a spatial map of radionuclides within a sample or surface in real-time as charged particles (betas) and photons (gamma/x-rays) are detected and localized on an event-by-event basis. Knowledge of the location and nature of radioactive hot spots on the ESS could provide information for subsequent laboratory analysis. As a nondestructive technique, QDARES does not compromise the ESS chain of custody or subsequent laboratory analysis. In this paper we will present the system design and construction, characterization measurements with calibration sources, and initial measurements of ESS.« less

  14. Kinetics of Poliovirus Shedding following Oral Vaccination as Measured by Quantitative Reverse Transcription-PCR versus Culture

    PubMed Central

    Begum, Sharmin; Uddin, Md Jashim; Platts-Mills, James A.; Liu, Jie; Kirkpatrick, Beth D.; Chowdhury, Anwarul H.; Jamil, Khondoker M.; Haque, Rashidul; Petri, William A.; Houpt, Eric R.

    2014-01-01

    Amid polio eradication efforts, detection of oral polio vaccine (OPV) virus in stool samples can provide information about rates of mucosal immunity and allow estimation of the poliovirus reservoir. We developed a multiplex one-step quantitative reverse transcription-PCR (qRT-PCR) assay for detection of OPV Sabin strains 1, 2, and 3 directly in stool samples with an external control to normalize samples for viral quantity and compared its performance with that of viral culture. We applied the assay to samples from infants in Dhaka, Bangladesh, after the administration of trivalent OPV (tOPV) at weeks 14 and 52 of life (on days 0 [pre-OPV], +4, +11, +18, and +25 relative to vaccination). When 1,350 stool samples were tested, the sensitivity and specificity of the quantitative PCR (qPCR) assay were 89 and 91% compared with culture. A quantitative relationship between culture+/qPCR+ and culture−/qPCR+ stool samples was observed. The kinetics of shedding revealed by qPCR and culture were similar. qPCR quantitative cutoffs based on the day +11 or +18 stool samples could be used to identify the culture-positive shedders, as well as the long-duration or high-frequency shedders. Interestingly, qPCR revealed that a small minority (7%) of infants contributed the vast majority (93 to 100%) of the total estimated viral excretion across all subtypes at each time point. This qPCR assay for OPV can simply and quantitatively detect all three Sabin strains directly in stool samples to approximate shedding both qualitatively and quantitatively. PMID:25378579

  15. Quantitative transmission Raman spectroscopy of pharmaceutical tablets and capsules.

    PubMed

    Johansson, Jonas; Sparén, Anders; Svensson, Olof; Folestad, Staffan; Claybourn, Mike

    2007-11-01

    Quantitative analysis of pharmaceutical formulations using the new approach of transmission Raman spectroscopy has been investigated. For comparison, measurements were also made in conventional backscatter mode. The experimental setup consisted of a Raman probe-based spectrometer with 785 nm excitation for measurements in backscatter mode. In transmission mode the same system was used to detect the Raman scattered light, while an external diode laser of the same type was used as excitation source. Quantitative partial least squares models were developed for both measurement modes. The results for tablets show that the prediction error for an independent test set was lower for the transmission measurements with a relative root mean square error of about 2.2% as compared with 2.9% for the backscatter mode. Furthermore, the models were simpler in the transmission case, for which only a single partial least squares (PLS) component was required to explain the variation. The main reason for the improvement using the transmission mode is a more representative sampling of the tablets compared with the backscatter mode. Capsules containing mixtures of pharmaceutical powders were also assessed by transmission only. The quantitative results for the capsules' contents were good, with a prediction error of 3.6% w/w for an independent test set. The advantage of transmission Raman over backscatter Raman spectroscopy has been demonstrated for quantitative analysis of pharmaceutical formulations, and the prospects for reliable, lean calibrations for pharmaceutical analysis is discussed.

  16. Quantitative autoradiographic mapping of focal herpes simplex virus encephalitis using a radiolabeled antiviral drug

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Price, R.

    1984-12-18

    A method of mapping herpes simplex viral infection comprising administering a radiolabeled antiviral active 5-substituted 1-(2'-deoxy-2'-substituted-D-arabinofuranosyl) pyrimidine nucleoside to the infected subject, and scanning the area in which the infection is to be mapped for the radiolabel.

  17. Reproducibility of Direct Quantitative Measures of Cortical Bone Micro-architecture of the Distal Radius and Tibia by HR-pQCT

    PubMed Central

    Burghardt, Andrew J.; Buie, Helen R.; Laib, Andres; Majumdar, Sharmila; Boyd, Steven K.

    2010-01-01

    Quantitative cortical micro-architectural endpoints are important for understanding structure-function relations in the context of fracture risk and therapeutic efficacy. This technique study details new image-processing methods to automatically segment and directly quantify cortical density, geometry, and micro-architecture from HR-pQCT images of the distal radius and tibia. An automated segmentation technique was developed to identify the periosteal and endosteal margins of the distal radius and tibia, and detect intra-cortical pore space morphologically consistent with Haversian canals. The reproducibility of direct quantitative cortical bone indices based on this method was assessed in a pooled dataset of 56 subjects with two repeat acquisitions for each site. The in vivo precision error was characterized using root mean square coefficient of variation (RMSCV%) from which, the least significant change (LSC) was calculated. Bland-Altman plots were used to characterize bias in the precision estimates. The reproducibility of cortical density and cross-sectional area measures was high (RMSCV <1% and <1.5%, respectively) with good agreement between young and elder medians. The LSC for cortical porosity (Ct.Po) was somewhat smaller in the radius (0.58%) compared with the distal tibia (0.84%) and significantly different between young and elder medians in the distal tibia (LSC: 0.75% vs. 0.92%; p<0.001). The LSC for pore diameter and distribution (Po.Dm and Po.Dm.SD) ranged between 15 and 23μm. Bland-Altman analysis revealed moderate bias for integral measures of area and volume, but not density nor microarchitecture. This study indicates HR-pQCT measures of cortical bone density and architecture can be measured in vivo with high reproducibility and limited bias across a biologically relevant range of values. The results of this study provide informative data for the design of future clinical studies of bone quality. PMID:20561906

  18. Lateral Asymmetry and Spatial Difference of Iron Deposition in the Substantia Nigra of Patients with Parkinson Disease Measured with Quantitative Susceptibility Mapping.

    PubMed

    Azuma, M; Hirai, T; Yamada, K; Yamashita, S; Ando, Y; Tateishi, M; Iryo, Y; Yoneda, T; Kitajima, M; Wang, Y; Yamashita, Y

    2016-05-01

    Quantitative susceptibility mapping is useful for assessing iron deposition in the substantia nigra of patients with Parkinson disease. We aimed to determine whether quantitative susceptibility mapping is useful for assessing the lateral asymmetry and spatial difference in iron deposits in the substantia nigra of patients with Parkinson disease. Our study population comprised 24 patients with Parkinson disease and 24 age- and sex-matched healthy controls. They underwent 3T MR imaging by using a 3D multiecho gradient-echo sequence. On reconstructed quantitative susceptibility mapping, we measured the susceptibility values in the anterior, middle, and posterior parts of the substantia nigra, the whole substantia nigra, and other deep gray matter structures in both hemibrains. To identify the more and less affected hemibrains in patients with Parkinson disease, we assessed the severity of movement symptoms for each hemibrain by using the Unified Parkinson's Disease Rating Scale. In the posterior substantia nigra of patients with Parkinson disease, the mean susceptibility value was significantly higher in the more than the less affected hemibrain substantia nigra (P < .05). This value was significantly higher in both the more and less affected hemibrains of patients with Parkinson disease than in controls (P < .05). Asymmetry of the mean susceptibility values was significantly greater for patients than controls (P < .05). Receiver operating characteristic analysis showed that quantitative susceptibility mapping of the posterior substantia nigra in the more affected hemibrain provided the highest power for discriminating patients with Parkinson disease from the controls. Quantitative susceptibility mapping is useful for assessing the lateral asymmetry and spatial difference of iron deposition in the substantia nigra of patients with Parkinson disease. © 2016 by American Journal of Neuroradiology.

  19. Quantitative FE-EPMA measurement of formation and inhibition of carbon contamination on Fe for trace carbon analysis.

    PubMed

    Tanaka, Yuji; Yamashita, Takako; Nagoshi, Masayasu

    2017-04-01

    Hydrocarbon contamination introduced during point, line and map analyses in a field emission electron probe microanalysis (FE-EPMA) was investigated to enable reliable quantitative analysis of trace amounts of carbon in steels. The increment of contamination on pure iron in point analysis is proportional to the number of iterations of beam irradiation, but not to the accumulated irradiation time. A combination of a longer dwell time and single measurement with a liquid nitrogen (LN2) trap as an anti-contamination device (ACD) is sufficient for a quantitative point analysis. However, in line and map analyses, contamination increases with irradiation time in addition to the number of iterations, even though the LN2 trap and a plasma cleaner are used as ACDs. Thus, a shorter dwell time and single measurement are preferred for line and map analyses, although it is difficult to eliminate the influence of contamination. While ring-like contamination around the irradiation point grows during electron-beam irradiation, contamination at the irradiation point increases during blanking time after irradiation. This can explain the increment of contamination in iterative point analysis as well as in line and map analyses. Among the ACDs, which are tested in this study, specimen heating at 373 K has a significant contamination inhibition effect. This technique makes it possible to obtain line and map analysis data with minimum influence of contamination. The above-mentioned FE-EPMA data are presented and discussed in terms of the contamination-formation mechanisms and the preferable experimental conditions for the quantification of trace carbon in steels. © The Author 2016. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  20. A tunable ratiometric pH sensor based on carbon nanodots for the quantitative measurement of the intracellular pH of whole cells.

    PubMed

    Shi, Wen; Li, Xiaohua; Ma, Huimin

    2012-06-25

    The whole picture: Carbon nanodots labeled with two fluorescent dyes have been developed as a tunable ratiometric pH sensor to measure intracellular pH. The nanosensor shows good biocompatibility and cellular dispersibility. Quantitative determinations on intact HeLa cells and pH fluctuations associated with oxidative stress were performed. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Reliability of quantitative EEG (qEEG) measures and LORETA current source density at 30 days.

    PubMed

    Cannon, Rex L; Baldwin, Debora R; Shaw, Tiffany L; Diloreto, Dominic J; Phillips, Sherman M; Scruggs, Annie M; Riehl, Timothy C

    2012-06-14

    There is a growing interest for using quantitative EEG and LORETA current source density in clinical and research settings. Importantly, if these indices are to be employed in clinical settings then the reliability of these measures is of great concern. Neuroguide (Applied Neurosciences) is sophisticated software developed for the analyses of power, and connectivity measures of the EEG as well as LORETA current source density. To date there are relatively few data evaluating topographical EEG reliability contrasts for all 19 channels and no studies have evaluated reliability for LORETA calculations. We obtained 4 min eyes-closed and eyes-opened EEG recordings at 30-day intervals. The EEG was analyzed in Neuroguide and FFT power, coherence and phase was computed for traditional frequency bands (delta, theta, alpha and beta) and LORETA current source density was calculated in 1 Hz increments and summed for total power in eight regions of interest (ROI). In order to obtain a robust measure of reliability we utilized a random effects model with an absolute agreement definition. The results show very good reproducibility for total absolute power and coherence. Phase shows lower reliability coefficients. LORETA current source density shows very good reliability with an average 0.81 for ECB and 0.82 for EOB. Similarly, the eight regions of interest show good to very good agreement across time. Implications for future directions and use of qEEG and LORETA in clinical populations are discussed. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  2. Quantitative imaging biomarkers: a review of statistical methods for technical performance assessment.

    PubMed

    Raunig, David L; McShane, Lisa M; Pennello, Gene; Gatsonis, Constantine; Carson, Paul L; Voyvodic, James T; Wahl, Richard L; Kurland, Brenda F; Schwarz, Adam J; Gönen, Mithat; Zahlmann, Gudrun; Kondratovich, Marina V; O'Donnell, Kevin; Petrick, Nicholas; Cole, Patricia E; Garra, Brian; Sullivan, Daniel C

    2015-02-01

    Technological developments and greater rigor in the quantitative measurement of biological features in medical images have given rise to an increased interest in using quantitative imaging biomarkers to measure changes in these features. Critical to the performance of a quantitative imaging biomarker in preclinical or clinical settings are three primary metrology areas of interest: measurement linearity and bias, repeatability, and the ability to consistently reproduce equivalent results when conditions change, as would be expected in any clinical trial. Unfortunately, performance studies to date differ greatly in designs, analysis method, and metrics used to assess a quantitative imaging biomarker for clinical use. It is therefore difficult or not possible to integrate results from different studies or to use reported results to design studies. The Radiological Society of North America and the Quantitative Imaging Biomarker Alliance with technical, radiological, and statistical experts developed a set of technical performance analysis methods, metrics, and study designs that provide terminology, metrics, and methods consistent with widely accepted metrological standards. This document provides a consistent framework for the conduct and evaluation of quantitative imaging biomarker performance studies so that results from multiple studies can be compared, contrasted, or combined. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  3. Reliability and group differences in quantitative cervicothoracic measures among individuals with and without chronic neck pain

    PubMed Central

    2012-01-01

    Background Clinicians frequently rely on subjective categorization of impairments in mobility, strength, and endurance for clinical decision-making; however, these assessments are often unreliable and lack sensitivity to change. The objective of this study was to determine the inter-rater reliability, minimum detectable change (MDC), and group differences in quantitative cervicothoracic measures for individuals with and without chronic neck pain (NP). Methods Nineteen individuals with NP and 20 healthy controls participated in this case control study. Two physical therapists performed a 30-minute examination on separate days. A handheld dynamometer, gravity inclinometer, ruler, and stopwatch were used to quantify cervical range of motion (ROM), cervical muscle strength and endurance, and scapulothoracic muscle length and strength, respectively. Results Intraclass correlation coefficients for inter-rater reliability were significantly greater than zero for most impairment measures, with point estimates ranging from 0.45 to 0.93. The NP group exhibited reduced cervical ROM (P ≤ 0.012) and muscle strength (P ≤ 0.038) in most movement directions, reduced cervical extensor endurance (P = 0.029), and reduced rhomboid and middle trapezius muscle strength (P ≤ 0.049). Conclusions Results demonstrate the feasibility of obtaining objective cervicothoracic impairment measures with acceptable inter-rater agreement across time. The clinical utility of these measures is supported by evidence of impaired mobility, strength, and endurance among patients with NP, with corresponding MDC values that can help establish benchmarks for clinically significant change. PMID:23114092

  4. Quantitative fluorescence angiography for neurosurgical interventions.

    PubMed

    Weichelt, Claudia; Duscha, Philipp; Steinmeier, Ralf; Meyer, Tobias; Kuß, Julia; Cimalla, Peter; Kirsch, Matthias; Sobottka, Stephan B; Koch, Edmund; Schackert, Gabriele; Morgenstern, Ute

    2013-06-01

    Present methods for quantitative measurement of cerebral perfusion during neurosurgical operations require additional technology for measurement, data acquisition, and processing. This study used conventional fluorescence video angiography--as an established method to visualize blood flow in brain vessels--enhanced by a quantifying perfusion software tool. For these purposes, the fluorescence dye indocyanine green is given intravenously, and after activation by a near-infrared light source the fluorescence signal is recorded. Video data are analyzed by software algorithms to allow quantification of the blood flow. Additionally, perfusion is measured intraoperatively by a reference system. Furthermore, comparing reference measurements using a flow phantom were performed to verify the quantitative blood flow results of the software and to validate the software algorithm. Analysis of intraoperative video data provides characteristic biological parameters. These parameters were implemented in the special flow phantom for experimental validation of the developed software algorithms. Furthermore, various factors that influence the determination of perfusion parameters were analyzed by means of mathematical simulation. Comparing patient measurement, phantom experiment, and computer simulation under certain conditions (variable frame rate, vessel diameter, etc.), the results of the software algorithms are within the range of parameter accuracy of the reference methods. Therefore, the software algorithm for calculating cortical perfusion parameters from video data presents a helpful intraoperative tool without complex additional measurement technology.

  5. Spotsizer: High-throughput quantitative analysis of microbial growth.

    PubMed

    Bischof, Leanne; Převorovský, Martin; Rallis, Charalampos; Jeffares, Daniel C; Arzhaeva, Yulia; Bähler, Jürg

    2016-10-01

    Microbial colony growth can serve as a useful readout in assays for studying complex genetic interactions or the effects of chemical compounds. Although computational tools for acquiring quantitative measurements of microbial colonies have been developed, their utility can be compromised by inflexible input image requirements, non-trivial installation procedures, or complicated operation. Here, we present the Spotsizer software tool for automated colony size measurements in images of robotically arrayed microbial colonies. Spotsizer features a convenient graphical user interface (GUI), has both single-image and batch-processing capabilities, and works with multiple input image formats and different colony grid types. We demonstrate how Spotsizer can be used for high-throughput quantitative analysis of fission yeast growth. The user-friendly Spotsizer tool provides rapid, accurate, and robust quantitative analyses of microbial growth in a high-throughput format. Spotsizer is freely available at https://data.csiro.au/dap/landingpage?pid=csiro:15330 under a proprietary CSIRO license.

  6. A quantitative assay measuring the function of lipase maturation factor 1

    PubMed Central

    Yin, Fen; Doolittle, Mark H.; Péterfy, Miklós

    2009-01-01

    Newly synthesized lipoprotein lipase (LPL) and related members of the lipase gene family require an endoplasmic reticulum maturation factor for attainment of enzyme activity. This factor has been identified as lipase maturation factor 1 (Lmf1), and mutations affecting its function and/or expression result in combined lipase deficiency (cld) and hypertriglyceridemia. To assess the functional impact of Lmf1 sequence variations, both naturally occurring and induced, we report the development of a cell-based assay using LPL activity as a quantitative reporter of Lmf1 function. The assay uses a cell line homozygous for the cld mutation, which renders endogenous Lmf1 nonfunctional. LPL transfected into the mutant cld cell line fails to attain activity; however, cotransfection of LPL with wild-type Lmf1 restores its ability to support normal lipase maturation. In this report, we describe optimized conditions that ensure the detection of a complete range of Lmf1 function (full, partial, or complete loss of function) using LPL activity as the quantitative reporter. To illustrate the dynamic range of the assay, we tested several novel mutations in mouse Lmf1. Our results demonstrate the ability of the assay to detect and analyze Lmf1 mutations having a wide range of effects on Lmf1 function and protein expression. PMID:19471043

  7. [Imaging and quantitative measurement of brain extracellular space using MRI Gd-DTPA tracer method].

    PubMed

    He, Qing-yuan; Han, Hong-bin; Xu, Fang-jing-wei; Yan, Jun-hao; Zeng, Jin-jin; Li, Xiao-gang; Fu, Yu; Peng, Yun; Chen, He; Hou, Chao; Xu, Xiao-juan

    2010-04-18

    To observe the diffusion of Gd-DTPA in brain extracellular space (ECS) by magnetic resonance imaging(MRI) and investigate the feasibility of ECS measurement by using MRI tracer method in vivo. 2 microL Gd-DTPA was introduced into ECS by caudate nucleus according to stereotaxic atlas in 8 Sprague Dawley(SD) rats (male, 280-320 g). The MRI scans were performed at 1 h, 3 h, 6 h, 9 h and 12 h respectively after administration. MRI appearances of Gd-DTPA diffusion and distribution was observed and compared. The MRI signal enhancement was measured at each time point. The neuroethology assessment was performed after MRI scanning at 12 h. The injection was accurate at the center of the caudate nucleus in 6 rats, while, at the capsula externa in other 2 rats. Gd-DTPA diffused isotropically after it was introduced into caudate nucleus, which spread into lateral cortex at 3 h. The MRI signal enhancement distributed mainly in the middle cerebral artery territory. A significant difference was found between the signal enhancement ratio at 1 h and that at 3 h in the original point of caudate nucleus (t=95.63, P<0.01), and the signal enhancement attenuated following the exponential power function y=1.7886x(-0.1776) (R2=0.94). In 2 rats with the injection point at capsula externa, Gd-DTPA diffused anisotropically along the fiber track of white matter during 1 h to 3 h, and spread into the lateral cortex at 6 h. The diffusion and clearance of Gd-DTPA in brain ECS could be monitored and measured quantitatively in vivo by MRI tracer method.

  8. A Quantitative Comparative Study Measuring Consumer Satisfaction Based on Health Record Format

    ERIC Educational Resources Information Center

    Moore, Vivianne E.

    2013-01-01

    This research study used a quantitative comparative method to investigate the relationship between consumer satisfaction and communication based on the format of health record. The central problem investigated in this research study related to the format of health record used and consumer satisfaction with care provided and effect on communication…

  9. An overview of quantitative approaches in Gestalt perception.

    PubMed

    Jäkel, Frank; Singh, Manish; Wichmann, Felix A; Herzog, Michael H

    2016-09-01

    Gestalt psychology is often criticized as lacking quantitative measurements and precise mathematical models. While this is true of the early Gestalt school, today there are many quantitative approaches in Gestalt perception and the special issue of Vision Research "Quantitative Approaches in Gestalt Perception" showcases the current state-of-the-art. In this article we give an overview of these current approaches. For example, ideal observer models are one of the standard quantitative tools in vision research and there is a clear trend to try and apply this tool to Gestalt perception and thereby integrate Gestalt perception into mainstream vision research. More generally, Bayesian models, long popular in other areas of vision research, are increasingly being employed to model perceptual grouping as well. Thus, although experimental and theoretical approaches to Gestalt perception remain quite diverse, we are hopeful that these quantitative trends will pave the way for a unified theory. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Quantitative single-particle digital autoradiography with α-particle emitters for targeted radionuclide therapy using the iQID camera

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Brian W., E-mail: brian.miller@pnnl.gov; Frost, Sofia H. L.; Frayo, Shani L.

    2015-07-15

    Purpose: Alpha-emitting radionuclides exhibit a potential advantage for cancer treatments because they release large amounts of ionizing energy over a few cell diameters (50–80 μm), causing localized, irreparable double-strand DNA breaks that lead to cell death. Radioimmunotherapy (RIT) approaches using monoclonal antibodies labeled with α emitters may thus inactivate targeted cells with minimal radiation damage to surrounding tissues. Tools are needed to visualize and quantify the radioactivity distribution and absorbed doses to targeted and nontargeted cells for accurate dosimetry of all treatment regimens utilizing α particles, including RIT and others (e.g., Ra-223), especially for organs and tumors with heterogeneous radionuclidemore » distributions. The aim of this study was to evaluate and characterize a novel single-particle digital autoradiography imager, the ionizing-radiation quantum imaging detector (iQID) camera, for use in α-RIT experiments. Methods: The iQID camera is a scintillator-based radiation detection system that images and identifies charged-particle and gamma-ray/x-ray emissions spatially and temporally on an event-by-event basis. It employs CCD-CMOS cameras and high-performance computing hardware for real-time imaging and activity quantification of tissue sections, approaching cellular resolutions. In this work, the authors evaluated its characteristics for α-particle imaging, including measurements of intrinsic detector spatial resolutions and background count rates at various detector configurations and quantification of activity distributions. The technique was assessed for quantitative imaging of astatine-211 ({sup 211}At) activity distributions in cryosections of murine and canine tissue samples. Results: The highest spatial resolution was measured at ∼20 μm full width at half maximum and the α-particle background was measured at a rate as low as (2.6 ± 0.5) × 10{sup −4} cpm/cm{sup 2} (40 mm diameter detector area

  11. Optical tweezers based force measurement system for quantitating binding interactions: system design and application for the study of bacterial adhesion.

    PubMed

    Fällman, Erik; Schedin, Staffan; Jass, Jana; Andersson, Magnus; Uhlin, Bernt Eric; Axner, Ove

    2004-06-15

    An optical force measurement system for quantitating forces in the pN range between micrometer-sized objects has been developed. The system was based upon optical tweezers in combination with a sensitive position detection system and constructed around an inverted microscope. A trapped particle in the focus of the high numerical aperture microscope-objective behaves like an omnidirectional mechanical spring in response to an external force. The particle's displacement from the equilibrium position is therefore a direct measure of the exerted force. A weak probe laser beam, focused directly below the trapping focus, was used for position detection of the trapped particle (a polystyrene bead). The bead and the condenser focus the light to a distinct spot in the far field, monitored by a position sensitive detector. Various calibration procedures were implemented in order to provide absolute force measurements. The system has been used to measure the binding forces between Escherichia coli bacterial adhesins and galabiose-functionalized beads.

  12. Quantitative Primary Tumor Indocyanine Green Measurements Predict Osteosarcoma Metastatic Lung Burden in a Mouse Model.

    PubMed

    Fourman, Mitchell S; Mahjoub, Adel; Mandell, Jon B; Yu, Shibing; Tebbets, Jessica C; Crasto, Jared A; Alexander, Peter E; Weiss, Kurt R

    2018-03-01

    Current preclinical osteosarcoma (OS) models largely focus on quantifying primary tumor burden. However, most fatalities from OS are caused by metastatic disease. The quantification of metastatic OS currently relies on CT, which is limited by motion artifact, requires intravenous contrast, and can be technically demanding in the preclinical setting. We describe the ability for indocyanine green (ICG) fluorescence angiography to quantify primary and metastatic OS in a previously validated orthotopic, immunocompetent mouse model. (1) Can near-infrared ICG fluorescence be used to attach a comparable, quantitative value to the primary OS tumor in our experimental mouse model? (2) Will primary tumor fluorescence differ in mice that go on to develop metastatic lung disease? (3) Does primary tumor fluorescence correlate with tumor volume measured with CT? Six groups of 4- to 6-week-old immunocompetent Balb/c mice (n = 6 per group) received paraphyseal injections into their left hindlimb proximal tibia consisting of variable numbers of K7M2 mouse OS cells. A hindlimb transfemoral amputation was performed 4 weeks after injection with euthanasia and lung extraction performed 10 weeks after injection. Histologic examination of lung and primary tumor specimens confirmed ICG localization only within the tumor bed. Mice with visible or palpable tumor growth had greater hindlimb fluorescence (3.5 ± 2.3 arbitrary perfusion units [APU], defined as the fluorescence pixel return normalized by the detector) compared with those with a negative examination (0.71 ± 0.38 APU, -2.7 ± 0.5 mean difference, 95% confidence interval -3.7 to -1.8, p < 0.001). A strong linear trend (r = 0.81, p < 0.01) was observed between primary tumor and lung fluorescence, suggesting that quantitative ICG tumor fluorescence is directly related to eventual metastatic burden. We did not find a correlation (r = 0.04, p = 0.45) between normalized primary tumor fluorescence and CT volumetric measurements. We

  13. A bottom-up approach in estimating the measurement uncertainty and other important considerations for quantitative analyses in drug testing for horses.

    PubMed

    Leung, Gary N W; Ho, Emmie N M; Kwok, W Him; Leung, David K K; Tang, Francis P W; Wan, Terence S M; Wong, April S Y; Wong, Colton H F; Wong, Jenny K Y; Yu, Nola H

    2007-09-07

    Quantitative determination, particularly for threshold substances in biological samples, is much more demanding than qualitative identification. A proper assessment of any quantitative determination is the measurement uncertainty (MU) associated with the determined value. The International Standard ISO/IEC 17025, "General requirements for the competence of testing and calibration laboratories", has more prescriptive requirements on the MU than its superseded document, ISO/IEC Guide 25. Under the 2005 or 1999 versions of the new standard, an estimation of the MU is mandatory for all quantitative determinations. To comply with the new requirement, a protocol was established in the authors' laboratory in 2001. The protocol has since evolved based on our practical experience, and a refined version was adopted in 2004. This paper describes our approach in establishing the MU, as well as some other important considerations, for the quantification of threshold substances in biological samples as applied in the area of doping control for horses. The testing of threshold substances can be viewed as a compliance test (or testing to a specified limit). As such, it should only be necessary to establish the MU at the threshold level. The steps in a "Bottom-Up" approach adopted by us are similar to those described in the EURACHEM/CITAC guide, "Quantifying Uncertainty in Analytical Measurement". They involve first specifying the measurand, including the relationship between the measurand and the input quantities upon which it depends. This is followed by identifying all applicable uncertainty contributions using a "cause and effect" diagram. The magnitude of each uncertainty component is then calculated and converted to a standard uncertainty. A recovery study is also conducted to determine if the method bias is significant and whether a recovery (or correction) factor needs to be applied. All standard uncertainties with values greater than 30% of the largest one are then used to

  14. Living cell dry mass measurement using quantitative phase imaging with quadriwave lateral shearing interferometry: an accuracy and sensitivity discussion.

    PubMed

    Aknoun, Sherazade; Savatier, Julien; Bon, Pierre; Galland, Frédéric; Abdeladim, Lamiae; Wattellier, Benoit; Monneret, Serge

    2015-01-01

    Single-cell dry mass measurement is used in biology to follow cell cycle, to address effects of drugs, or to investigate cell metabolism. Quantitative phase imaging technique with quadriwave lateral shearing interferometry (QWLSI) allows measuring cell dry mass. The technique is very simple to set up, as it is integrated in a camera-like instrument. It simply plugs onto a standard microscope and uses a white light illumination source. Its working principle is first explained, from image acquisition to automated segmentation algorithm and dry mass quantification. Metrology of the whole process, including its sensitivity, repeatability, reliability, sources of error, over different kinds of samples and under different experimental conditions, is developed. We show that there is no influence of magnification or spatial light coherence on dry mass measurement; effect of defocus is more critical but can be calibrated. As a consequence, QWLSI is a well-suited technique for fast, simple, and reliable cell dry mass study, especially for live cells.

  15. Identification of common coexpression modules based on quantitative network comparison.

    PubMed

    Jo, Yousang; Kim, Sanghyeon; Lee, Doheon

    2018-06-13

    Finding common molecular interactions from different samples is essential work to understanding diseases and other biological processes. Coexpression networks and their modules directly reflect sample-specific interactions among genes. Therefore, identification of common coexpression network or modules may reveal the molecular mechanism of complex disease or the relationship between biological processes. However, there has been no quantitative network comparison method for coexpression networks and we examined previous methods for other networks that cannot be applied to coexpression network. Therefore, we aimed to propose quantitative comparison methods for coexpression networks and to find common biological mechanisms between Huntington's disease and brain aging by the new method. We proposed two similarity measures for quantitative comparison of coexpression networks. Then, we performed experiments using known coexpression networks. We showed the validity of two measures and evaluated threshold values for similar coexpression network pairs from experiments. Using these similarity measures and thresholds, we quantitatively measured the similarity between disease-specific and aging-related coexpression modules and found similar Huntington's disease-aging coexpression module pairs. We identified similar Huntington's disease-aging coexpression module pairs and found that these modules are related to brain development, cell death, and immune response. It suggests that up-regulated cell signalling related cell death and immune/ inflammation response may be the common molecular mechanisms in the pathophysiology of HD and normal brain aging in the frontal cortex.

  16. Quantitative and qualitative measure of intralaboratory two-dimensional protein gel reproducibility and the effects of sample preparation, sample load, and image analysis.

    PubMed

    Choe, Leila H; Lee, Kelvin H

    2003-10-01

    We investigate one approach to assess the quantitative variability in two-dimensional gel electrophoresis (2-DE) separations based on gel-to-gel variability, sample preparation variability, sample load differences, and the effect of automation on image analysis. We observe that 95% of spots present in three out of four replicate gels exhibit less than a 0.52 coefficient of variation (CV) in fluorescent stain intensity (% volume) for a single sample run on multiple gels. When four parallel sample preparations are performed, this value increases to 0.57. We do not observe any significant change in quantitative value for an increase or decrease in sample load of 30% when using appropriate image analysis variables. Increasing use of automation, while necessary in modern 2-DE experiments, does change the observed level of quantitative and qualitative variability among replicate gels. The number of spots that change qualitatively for a single sample run in parallel varies from a CV = 0.03 for fully manual analysis to CV = 0.20 for a fully automated analysis. We present a systematic method by which a single laboratory can measure gel-to-gel variability using only three gel runs.

  17. Quantitative measurement of human thyroglobulin-specific antibodies by use of a sensitive enzyme-linked immunoassay.

    PubMed

    Kuppers, R C; Outschoorn, I M; Hamilton, R G; Burek, C L; Rose, N R

    1993-04-01

    A quantitative enzyme-linked immunoassay that measures in absolute terms the subclass concentration of human thyroglobulin (huTg)-specific IgG autoantibody was developed. Unique to this study was the use of an affinity-purified anti-huTg standard with a known concentration of the four IgG subclasses. The sensitivity of the ELISA assay was 1-5 ng/ml depending on the IgG subclass being measured. We examined 22 sera of patients with autoimmune thyroid disease. The total huTg-specific antibody concentrations in serum ranged from 0 to nearly 3000 micrograms/ml of IgG. The IgG subclass distribution in individuals with low huTg-specific IgG (< 10 micrograms/ml) was primarily IgG1 and IgG3 Ab. Patients with intermediate levels of huTg IgG (10-600 micrograms/ml) expressed all four subclasses; however, no particular subclass was dominant. Individuals with > 1000 micrograms/ml also showed huTg-Ab in all four subclasses, however, IgG1 and IgG2 were dominant. All four IgG subclasses were used in the response to huTg, although the pattern of usage varied between individuals. There was no dominant subclass usage seen in this patient population.

  18. Quantitative measurement and analysis for detection and treatment planning of developmental dysplasia of the hip

    NASA Astrophysics Data System (ADS)

    Liu, Xin; Lu, Hongbing; Chen, Hanyong; Zhao, Li; Shi, Zhengxing; Liang, Zhengrong

    2009-02-01

    Developmental dysplasia of the hip is a congenital hip joint malformation affecting the proximal femurs and acetabulum that are subluxatable, dislocatable, and dislocated. Conventionally, physicians made diagnoses and treatments only based on findings from two-dimensional (2D) images by manually calculating clinic parameters. However, anatomical complexity of the disease and the limitation of current standard procedures make accurate diagnosis quite difficultly. In this study, we developed a system that provides quantitative measurement of 3D clinical indexes based on computed tomography (CT) images. To extract bone structure from surrounding tissues more accurately, the system firstly segments the bone using a knowledge-based fuzzy clustering method, which is formulated by modifying the objective function of the standard fuzzy c-means algorithm with additive adaptation penalty. The second part of the system calculates automatically the clinical indexes, which are extended from 2D to 3D for accurate description of spatial relationship between femurs and acetabulum. To evaluate the system performance, experimental study based on 22 patients with unilateral or bilateral affected hip was performed. The results of 3D acetabulum index (AI) automatically provided by the system were validated by comparison with 2D results measured by surgeons manually. The correlation between the two results was found to be 0.622 (p<0.01).

  19. Validation of Greyscale-Based Quantitative Ultrasound in Manual Wheelchair Users

    PubMed Central

    Collinger, Jennifer L.; Fullerton, Bradley; Impink, Bradley G.; Koontz, Alicia M.; Boninger, Michael L.

    2010-01-01

    Objective The primary aim of this study is to establish the validity of greyscale-based quantitative ultrasound (QUS) measures of the biceps and supraspinatus tendons. Design Nine QUS measures of the biceps and supraspinatus tendons were computed from ultrasound images collected from sixty-seven manual wheelchair users. Shoulder pathology was measured using questionnaires, physical examination maneuvers, and a clinical ultrasound grading scale. Results Increased age, duration of wheelchair use, and body mass correlated with a darker, more homogenous tendon appearance. Subjects with pain during physical examination tests for biceps tenderness and acromioclavicular joint tenderness exhibited significantly different supraspinatus QUS values. Even when controlling for tendon depth, QUS measures of the biceps tendon differed significantly between subjects with healthy tendons, mild tendinosis, and severe tendinosis. Clinical grading of supraspinatus tendon health was correlated with QUS measures of the supraspinatus tendon. Conclusions Quantitative ultrasound is valid method to quantify tendinopathy and may allow for early detection of tendinosis. Manual wheelchair users are at a high risk for developing shoulder tendon pathology and may benefit from quantitative ultrasound-based research that focuses on identifying interventions designed to reduce this risk. PMID:20407304

  20. Quantitative Susceptibility Mapping after Sports-Related Concussion.

    PubMed

    Koch, K M; Meier, T B; Karr, R; Nencka, A S; Muftuler, L T; McCrea, M

    2018-06-07

    Quantitative susceptibility mapping using MR imaging can assess changes in brain tissue structure and composition. This report presents preliminary results demonstrating changes in tissue magnetic susceptibility after sports-related concussion. Longitudinal quantitative susceptibility mapping metrics were produced from imaging data acquired from cohorts of concussed and control football athletes. One hundred thirty-six quantitative susceptibility mapping datasets were analyzed across 3 separate visits (24 hours after injury, 8 days postinjury, and 6 months postinjury). Longitudinal quantitative susceptibility mapping group analyses were performed on stability-thresholded brain tissue compartments and selected subregions. Clinical concussion metrics were also measured longitudinally in both cohorts and compared with the measured quantitative susceptibility mapping. Statistically significant increases in white matter susceptibility were identified in the concussed athlete group during the acute (24 hour) and subacute (day 8) period. These effects were most prominent at the 8-day visit but recovered and showed no significant difference from controls at the 6-month visit. The subcortical gray matter showed no statistically significant group differences. Observed susceptibility changes after concussion appeared to outlast self-reported clinical recovery metrics at a group level. At an individual subject level, susceptibility increases within the white matter showed statistically significant correlations with return-to-play durations. The results of this preliminary investigation suggest that sports-related concussion can induce physiologic changes to brain tissue that can be detected using MR imaging-based magnetic susceptibility estimates. In group analyses, the observed tissue changes appear to persist beyond those detected on clinical outcome assessments and were associated with return-to-play duration after sports-related concussion. © 2018 by American Journal of

  1. Quantitative multiplex detection of pathogen biomarkers

    DOEpatents

    Mukundan, Harshini; Xie, Hongzhi; Swanson, Basil I.; Martinez, Jennifer; Grace, Wynne K.

    2016-02-09

    The present invention addresses the simultaneous detection and quantitative measurement of multiple biomolecules, e.g., pathogen biomarkers through either a sandwich assay approach or a lipid insertion approach. The invention can further employ a multichannel, structure with multi-sensor elements per channel.

  2. Quantitative multiplex detection of pathogen biomarkers

    DOEpatents

    Mukundan, Harshini; Xie, Hongzhi; Swanson, Basil I; Martinez, Jennifer; Grace, Wynne K

    2014-10-14

    The present invention addresses the simultaneous detection and quantitative measurement of multiple biomolecules, e.g., pathogen biomarkers through either a sandwich assay approach or a lipid insertion approach. The invention can further employ a multichannel, structure with multi-sensor elements per channel.

  3. Quantitative characterization of nanoscale polycrystalline magnets with electron magnetic circular dichroism.

    PubMed

    Muto, Shunsuke; Rusz, Ján; Tatsumi, Kazuyoshi; Adam, Roman; Arai, Shigeo; Kocevski, Vancho; Oppeneer, Peter M; Bürgler, Daniel E; Schneider, Claus M

    2014-01-01

    Electron magnetic circular dichroism (EMCD) allows the quantitative, element-selective determination of spin and orbital magnetic moments, similar to its well-established X-ray counterpart, X-ray magnetic circular dichroism (XMCD). As an advantage over XMCD, EMCD measurements are made using transmission electron microscopes, which are routinely operated at sub-nanometre resolution, thereby potentially allowing nanometre magnetic characterization. However, because of the low intensity of the EMCD signal, it has not yet been possible to obtain quantitative information from EMCD signals at the nanoscale. Here we demonstrate a new approach to EMCD measurements that considerably enhances the outreach of the technique. The statistical analysis introduced here yields robust quantitative EMCD signals. Moreover, we demonstrate that quantitative magnetic information can be routinely obtained using electron beams of only a few nanometres in diameter without imposing any restriction regarding the crystalline order of the specimen.

  4. SYN-JEM: A Quantitative Job-Exposure Matrix for Five Lung Carcinogens.

    PubMed

    Peters, Susan; Vermeulen, Roel; Portengen, Lützen; Olsson, Ann; Kendzia, Benjamin; Vincent, Raymond; Savary, Barbara; Lavoué, Jérôme; Cavallo, Domenico; Cattaneo, Andrea; Mirabelli, Dario; Plato, Nils; Fevotte, Joelle; Pesch, Beate; Brüning, Thomas; Straif, Kurt; Kromhout, Hans

    2016-08-01

    The use of measurement data in occupational exposure assessment allows more quantitative analyses of possible exposure-response relations. We describe a quantitative exposure assessment approach for five lung carcinogens (i.e. asbestos, chromium-VI, nickel, polycyclic aromatic hydrocarbons (by its proxy benzo(a)pyrene (BaP)) and respirable crystalline silica). A quantitative job-exposure matrix (JEM) was developed based on statistical modeling of large quantities of personal measurements. Empirical linear models were developed using personal occupational exposure measurements (n = 102306) from Europe and Canada, as well as auxiliary information like job (industry), year of sampling, region, an a priori exposure rating of each job (none, low, and high exposed), sampling and analytical methods, and sampling duration. The model outcomes were used to create a JEM with a quantitative estimate of the level of exposure by job, year, and region. Decreasing time trends were observed for all agents between the 1970s and 2009, ranging from -1.2% per year for personal BaP and nickel exposures to -10.7% for asbestos (in the time period before an asbestos ban was implemented). Regional differences in exposure concentrations (adjusted for measured jobs, years of measurement, and sampling method and duration) varied by agent, ranging from a factor 3.3 for chromium-VI up to a factor 10.5 for asbestos. We estimated time-, job-, and region-specific exposure levels for four (asbestos, chromium-VI, nickel, and RCS) out of five considered lung carcinogens. Through statistical modeling of large amounts of personal occupational exposure measurement data we were able to derive a quantitative JEM to be used in community-based studies. © The Author 2016. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  5. The NIST Quantitative Infrared Database

    PubMed Central

    Chu, P. M.; Guenther, F. R.; Rhoderick, G. C.; Lafferty, W. J.

    1999-01-01

    With the recent developments in Fourier transform infrared (FTIR) spectrometers it is becoming more feasible to place these instruments in field environments. As a result, there has been enormous increase in the use of FTIR techniques for a variety of qualitative and quantitative chemical measurements. These methods offer the possibility of fully automated real-time quantitation of many analytes; therefore FTIR has great potential as an analytical tool. Recently, the U.S. Environmental Protection Agency (U.S.EPA) has developed protocol methods for emissions monitoring using both extractive and open-path FTIR measurements. Depending upon the analyte, the experimental conditions and the analyte matrix, approximately 100 of the hazardous air pollutants (HAPs) listed in the 1990 U.S.EPA Clean Air Act amendment (CAAA) can be measured. The National Institute of Standards and Technology (NIST) has initiated a program to provide quality-assured infrared absorption coefficient data based on NIST prepared primary gas standards. Currently, absorption coefficient data has been acquired for approximately 20 of the HAPs. For each compound, the absorption coefficient spectrum was calculated using nine transmittance spectra at 0.12 cm−1 resolution and the Beer’s law relationship. The uncertainties in the absorption coefficient data were estimated from the linear regressions of the transmittance data and considerations of other error sources such as the nonlinear detector response. For absorption coefficient values greater than 1 × 10−4 μmol/mol)−1 m−1 the average relative expanded uncertainty is 2.2 %. This quantitative infrared database is currently an ongoing project at NIST. Additional spectra will be added to the database as they are acquired. Our current plans include continued data acquisition of the compounds listed in the CAAA, as well as the compounds that contribute to global warming and ozone depletion.

  6. How to Measure the Intervention Process? An Assessment of Qualitative and Quantitative Approaches to Data Collection in the Process Evaluation of Organizational Interventions

    PubMed Central

    Abildgaard, Johan S.; Saksvik, Per Ø.; Nielsen, Karina

    2016-01-01

    Organizational interventions aiming at improving employee health and wellbeing have proven to be challenging to evaluate. To analyze intervention processes two methodological approaches have widely been used: quantitative (often questionnaire data), or qualitative (often interviews). Both methods are established tools, but their distinct epistemological properties enable them to illuminate different aspects of organizational interventions. In this paper, we use the quantitative and qualitative process data from an organizational intervention conducted in a national postal service, where the Intervention Process Measure questionnaire (N = 285) as well as an extensive interview study (N = 50) were used. We analyze what type of knowledge about intervention processes these two methodologies provide and discuss strengths and weaknesses as well as potentials for mixed methods evaluation methodologies. PMID:27713707

  7. How to Measure the Intervention Process? An Assessment of Qualitative and Quantitative Approaches to Data Collection in the Process Evaluation of Organizational Interventions.

    PubMed

    Abildgaard, Johan S; Saksvik, Per Ø; Nielsen, Karina

    2016-01-01

    Organizational interventions aiming at improving employee health and wellbeing have proven to be challenging to evaluate. To analyze intervention processes two methodological approaches have widely been used: quantitative (often questionnaire data), or qualitative (often interviews). Both methods are established tools, but their distinct epistemological properties enable them to illuminate different aspects of organizational interventions. In this paper, we use the quantitative and qualitative process data from an organizational intervention conducted in a national postal service, where the Intervention Process Measure questionnaire ( N = 285) as well as an extensive interview study ( N = 50) were used. We analyze what type of knowledge about intervention processes these two methodologies provide and discuss strengths and weaknesses as well as potentials for mixed methods evaluation methodologies.

  8. Quantitative comparison of the pivot shift test results before and after anterior cruciate ligament reconstruction by using the three-dimensional electromagnetic measurement system.

    PubMed

    Nagai, Kanto; Hoshino, Yuichi; Nishizawa, Yuichiro; Araki, Daisuke; Matsushita, Takehiko; Matsumoto, Tomoyuki; Takayama, Koji; Nagamune, Kouki; Kurosaka, Masahiro; Kuroda, Ryosuke

    2015-10-01

    Tibial acceleration during the pivot shift test is a potential quantitative parameter to evaluate rotational laxity of anterior cruciate ligament (ACL) insufficiency. However, clinical application of this measurement has not been fully examined. This study aimed to measure and compare tibial acceleration before and after ACL reconstruction (ACLR) in ACL-injured patients. We hypothesized tibial acceleration would be reduced by ACLR and tibial acceleration would be consistent in the same knee at different time points. Seventy ACL-injured patients who underwent ACLR were enrolled. Tibial acceleration during the pivot shift test was measured using an electromagnetic measurement system before ALCR and at the second-look arthroscopy 1 year post-operatively. Tibial acceleration was compared to clinical grading and between ACL-injured/ACL-reconstructed and contralateral knees. Pre-operative tibial acceleration was increased stepwise with the increase in clinical grading (P < 0.01). Tibial acceleration in ACL-injured knee (1.9 ± 1.2 m/s(2)) was larger than that in the contralateral knee (0.8 ± 0.3 m/s(2), P < 0.01), and reduced to 0.9 ± 0.3 m/s(2) post-operatively (P < 0.01). There was no difference between ACL-reconstructed and contralateral knee (n.s.). Tibial acceleration in contralateral knees was consistent pre- and post-operatively (n.s.). Tibial acceleration measurement demonstrated increased rotational laxity in ACL-injured knees and its reduction by ALCR. Additionally, consistent measurements were obtained in ACL-intact knees at different time points. Therefore, tibial acceleration during the pivot shift test could provide quantitative evaluation of rotational stability before and after ACL reconstruction. III.

  9. Quantitative cell biology: the essential role of theory.

    PubMed

    Howard, Jonathon

    2014-11-05

    Quantitative biology is a hot area, as evidenced by the recent establishment of institutes, graduate programs, and conferences with that name. But what is quantitative biology? What should it be? And how can it contribute to solving the big questions in biology? The past decade has seen very rapid development of quantitative experimental techniques, especially at the single-molecule and single-cell levels. In this essay, I argue that quantitative biology is much more than just the quantitation of these experimental results. Instead, it should be the application of the scientific method by which measurement is directed toward testing theories. In this view, quantitative biology is the recognition that theory and models play critical roles in biology, as they do in physics and engineering. By tying together experiment and theory, quantitative biology promises a deeper understanding of underlying mechanisms, when the theory works, or to new discoveries, when it does not. © 2014 Howard. This article is distributed by The American Society for Cell Biology under license from the author(s). Two months after publication it is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).

  10. Log Normal Distribution of Cellular Uptake of Radioactivity: Statistical Analysis of Alpha Particle Track Autoradiography

    PubMed Central

    Neti, Prasad V.S.V.; Howell, Roger W.

    2008-01-01

    Recently, the distribution of radioactivity among a population of cells labeled with 210Po was shown to be well described by a log normal distribution function (J Nucl Med 47, 6 (2006) 1049-1058) with the aid of an autoradiographic approach. To ascertain the influence of Poisson statistics on the interpretation of the autoradiographic data, the present work reports on a detailed statistical analyses of these data. Methods The measured distributions of alpha particle tracks per cell were subjected to statistical tests with Poisson (P), log normal (LN), and Poisson – log normal (P – LN) models. Results The LN distribution function best describes the distribution of radioactivity among cell populations exposed to 0.52 and 3.8 kBq/mL 210Po-citrate. When cells were exposed to 67 kBq/mL, the P – LN distribution function gave a better fit, however, the underlying activity distribution remained log normal. Conclusions The present analysis generally provides further support for the use of LN distributions to describe the cellular uptake of radioactivity. Care should be exercised when analyzing autoradiographic data on activity distributions to ensure that Poisson processes do not distort the underlying LN distribution. PMID:16741316

  11. Methods for Quantitative Creatinine Determination.

    PubMed

    Moore, John F; Sharer, J Daniel

    2017-04-06

    Reliable measurement of creatinine is necessary to assess kidney function, and also to quantitate drug levels and diagnostic compounds in urine samples. The most commonly used methods are based on the Jaffe principal of alkaline creatinine-picric acid complex color formation. However, other compounds commonly found in serum and urine may interfere with Jaffe creatinine measurements. Therefore, many laboratories have made modifications to the basic method to remove or account for these interfering substances. This appendix will summarize the basic Jaffe method, as well as a modified, automated version. Also described is a high performance liquid chromatography (HPLC) method that separates creatinine from contaminants prior to direct quantification by UV absorption. Lastly, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method is described that uses stable isotope dilution to reliably quantify creatinine in any sample. This last approach has been recommended by experts in the field as a means to standardize all quantitative creatinine methods against an accepted reference. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  12. Measuring the remineralization potential of different agents with quantitative light-induced fluorescence digital Biluminator.

    PubMed

    Kucukyilmaz, Ebru; Savas, Selcuk

    2017-01-26

    The aim of this study was to investigate the effectiveness of different remineralization agents by quantitative light-induced fluorescence digital BiluminatorTM (QLF-D). Artificial caries lesions were created, and the teeth were divided according to the tested materials: (i) distilled water, (ii) acidulated phosphate fluoride (APF), (iii) Curodont Repair (CR), (iv) ammonium hexafluorosilicate (SiF) and (v) ammonium hexafluorosilicate plus cetylpyridinium chloride (SiF + CPC). After treatment procedures, each of the samples was placed in artificial saliva. After demineralization and 1 and 4 weeks of remineralization procedures, fluorescence loss and lesion areas were measured with QLF-D. Data were statistically analyzed (α = 0.05). The fluorescence values of the demineralized enamel specimens treated with the various agents differed significantly compared with pretreatment values for both 1 and 4 weeks (p<0.05). At 4 weeks, the highest fluorescence gain was calculated in the CR, APF and SiF groups compared with the control (p<0.05). APF, SiF and CR groups yielded greater remineralization ability than SiF + CPC and control groups.

  13. Correlated ion and neutral time of flight technique combined with velocity map imaging: Quantitative measurements for dissociation processes in excited molecular nano-systems

    NASA Astrophysics Data System (ADS)

    Berthias, F.; Feketeová, L.; Della Negra, R.; Dupasquier, T.; Fillol, R.; Abdoul-Carime, H.; Farizon, B.; Farizon, M.; Märk, T. D.

    2018-01-01

    The combination of the Dispositif d'Irradiation d'Agrégats Moléculaire with the correlated ion and neutral time of flight-velocity map imaging technique provides a new way to explore processes occurring subsequent to the excitation of charged nano-systems. The present contribution describes in detail the methods developed for the quantitative measurement of branching ratios and cross sections for collision-induced dissociation processes of water cluster nano-systems. These methods are based on measurements of the detection efficiency of neutral fragments produced in these dissociation reactions. Moreover, measured detection efficiencies are used here to extract the number of neutral fragments produced for a given charged fragment.

  14. UK audit of quantitative thyroid uptake imaging.

    PubMed

    Taylor, Jonathan C; Murray, Anthony W; Hall, David O; Barnfield, Mark C; O'Shaugnessy, Emma R; Carson, Kathryn J; Cullis, James; Towey, David J; Kenny, Bob

    2017-07-01

    A national audit of quantitative thyroid uptake imaging was conducted by the Nuclear Medicine Software Quality Group of the Institute of Physics and Engineering in Medicine in 2014/2015. The aims of the audit were to measure and assess the variability in thyroid uptake results across the UK and to compare local protocols with British Nuclear Medicine Society (BNMS) guidelines. Participants were invited through a combination of emails on a public mailbase and targeted invitations from regional co-ordinators. All participants were given a set of images from which to calculate quantitative measures and a spreadsheet for capturing results. The image data consisted of two sets of 10 anterior thyroid images, half of which were acquired after administration of Tc-pertechnetate and the other half after administration of I-iodide. Images of the administration syringes or thyroid phantoms were also included. In total, 54 participants responded to the audit. The median number of scans conducted per year was 50. A majority of centres had at least one noncompliance in comparison with BNMS guidelines. Of most concern was the widespread lack of injection-site imaging. Quantitative results showed that both intersite and intrasite variability were low for the Tc dataset. The coefficient of quartile deviation was between 0.03 and 0.13 for measurements of overall percentage uptake. Although the number of returns for the I dataset was smaller, the level of variability between participants was greater (the coefficient of quartile deviation was between 0.17 and 0.25). A UK-wide audit showed that thyroid uptake imaging is still a common test in the UK. It was found that most centres do not adhere to all aspects of the BNMS practice guidelines but that quantitative results are reasonably consistent for Tc-based scans.

  15. Quantitation of Met tyrosine phosphorylation using MRM-MS.

    PubMed

    Meng, Zhaojing; Srivastava, Apurva K; Zhou, Ming; Veenstra, Timothy

    2013-01-01

    Phosphorylation has long been accepted as a key cellular regulator of cell signaling pathways. The recent development of multiple-reaction monitoring mass spectrometry (MRM-MS) provides a useful tool for measuring the absolute quantity of phosphorylation occupancy at pivotal sites within signaling proteins, even when the phosphorylation sites are in close proximity. Here, we described a targeted quantitation approach to measure the absolute phosphorylation occupancy at Y1234 and Y1235 of Met. The approach is utilized to obtain absolute occupancy of the two phosphorylation sites in the full-length recombinant Met. It is further applied to quantitate the phosphorylation state of these two sites in SNU-5 cells treated with a Met inhibitor.

  16. Quantitating Human Optic Disc Topography

    NASA Astrophysics Data System (ADS)

    Graebel, William P.; Cohan, Bruce E.; Pearch, Andrew C.

    1980-07-01

    A method is presented for quantitatively expressing the topography of the human optic disc, applicable in a clinical setting to the diagnosis and management of glaucoma. Pho-tographs of the disc illuminated by a pattern of fine, high contrast parallel lines are digitized. From the measured deviation of the lines as they traverse the disc surface, disc topography is calculated, using the principles of optical sectioning. The quantitators applied to express this topography have the the following advantages : sensitivity to disc shape; objectivity; going beyond the limits of cup-disc ratio estimates and volume calculations; perfect generality in a mathematical sense; an inherent scheme for determining a non-subjective reference frame to compare different discs or the same disc over time.

  17. Diagnostic performance of semi-quantitative and quantitative stress CMR perfusion analysis: a meta-analysis.

    PubMed

    van Dijk, R; van Assen, M; Vliegenthart, R; de Bock, G H; van der Harst, P; Oudkerk, M

    2017-11-27

    Stress cardiovascular magnetic resonance (CMR) perfusion imaging is a promising modality for the evaluation of coronary artery disease (CAD) due to high spatial resolution and absence of radiation. Semi-quantitative and quantitative analysis of CMR perfusion are based on signal-intensity curves produced during the first-pass of gadolinium contrast. Multiple semi-quantitative and quantitative parameters have been introduced. Diagnostic performance of these parameters varies extensively among studies and standardized protocols are lacking. This study aims to determine the diagnostic accuracy of semi- quantitative and quantitative CMR perfusion parameters, compared to multiple reference standards. Pubmed, WebOfScience, and Embase were systematically searched using predefined criteria (3272 articles). A check for duplicates was performed (1967 articles). Eligibility and relevance of the articles was determined by two reviewers using pre-defined criteria. The primary data extraction was performed independently by two researchers with the use of a predefined template. Differences in extracted data were resolved by discussion between the two researchers. The quality of the included studies was assessed using the 'Quality Assessment of Diagnostic Accuracy Studies Tool' (QUADAS-2). True positives, false positives, true negatives, and false negatives were subtracted/calculated from the articles. The principal summary measures used to assess diagnostic accuracy were sensitivity, specificity, andarea under the receiver operating curve (AUC). Data was pooled according to analysis territory, reference standard and perfusion parameter. Twenty-two articles were eligible based on the predefined study eligibility criteria. The pooled diagnostic accuracy for segment-, territory- and patient-based analyses showed good diagnostic performance with sensitivity of 0.88, 0.82, and 0.83, specificity of 0.72, 0.83, and 0.76 and AUC of 0.90, 0.84, and 0.87, respectively. In per territory

  18. Quantitative assessment based on kinematic measures of functional impairments during upper extremity movements: A review.

    PubMed

    de los Reyes-Guzmán, Ana; Dimbwadyo-Terrer, Iris; Trincado-Alonso, Fernando; Monasterio-Huelin, Félix; Torricelli, Diego; Gil-Agudo, Angel

    2014-08-01

    Quantitative measures of human movement quality are important for discriminating healthy and pathological conditions and for expressing the outcomes and clinically important changes in subjects' functional state. However the most frequently used instruments for the upper extremity functional assessment are clinical scales, that previously have been standardized and validated, but have a high subjective component depending on the observer who scores the test. But they are not enough to assess motor strategies used during movements, and their use in combination with other more objective measures is necessary. The objective of the present review is to provide an overview on objective metrics found in literature with the aim of quantifying the upper extremity performance during functional tasks, regardless of the equipment or system used for registering kinematic data. A search in Medline, Google Scholar and IEEE Xplore databases was performed following a combination of a series of keywords. The full scientific papers that fulfilled the inclusion criteria were included in the review. A set of kinematic metrics was found in literature in relation to joint displacements, analysis of hand trajectories and velocity profiles. These metrics were classified into different categories according to the movement characteristic that was being measured. These kinematic metrics provide the starting point for a proposed objective metrics for the functional assessment of the upper extremity in people with movement disorders as a consequence of neurological injuries. Potential areas of future and further research are presented in the Discussion section. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Simultaneous measurement of cerebral blood flow and mRNA signals: pixel-based inter-modality correlational analysis.

    PubMed

    Zhao, W; Busto, R; Truettner, J; Ginsberg, M D

    2001-07-30

    The analysis of pixel-based relationships between local cerebral blood flow (LCBF) and mRNA expression can reveal important insights into brain function. Traditionally, LCBF and in situ hybridization studies for genes of interest have been analyzed in separate series. To overcome this limitation and to increase the power of statistical analysis, this study focused on developing a double-label method to measure local cerebral blood flow (LCBF) and gene expressions simultaneously by means of a dual-autoradiography procedure. A 14C-iodoantipyrine autoradiographic LCBF study was first performed. Serial brain sections (12 in this study) were obtained at multiple coronal levels and were processed in the conventional manner to yield quantitative LCBF images. Two replicate sections at each bregma level were then used for in situ hybridization. To eliminate the 14C-iodoantipyrine from these sections, a chloroform-washout procedure was first performed. The sections were then processed for in situ hybridization autoradiography for the probes of interest. This method was tested in Wistar rats subjected to 12 min of global forebrain ischemia by two-vessel occlusion plus hypotension, followed by 2 or 6 h of reperfusion (n=4-6 per group). LCBF and in situ hybridization images for heat shock protein 70 (HSP70) were generated for each rat, aligned by disparity analysis, and analyzed on a pixel-by-pixel basis. This method yielded detailed inter-modality correlation between LCBF and HSP70 mRNA expressions. The advantages of this method include reducing the number of experimental animals by one-half; and providing accurate pixel-based correlations between different modalities in the same animals, thus enabling paired statistical analyses. This method can be extended to permit correlation of LCBF with the expression of multiple genes of interest.

  20. Quantitative measurement of carbon isotopic composition in CO2 gas reservoir by Micro-Laser Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Li, Jiajia; Li, Rongxi; Zhao, Bangsheng; Guo, Hui; Zhang, Shuan; Cheng, Jinghua; Wu, Xiaoli

    2018-04-01

    The use of Micro-Laser Raman spectroscopy technology for quantitatively determining gas carbon isotope composition is presented. In this study, 12CO2 and 13CO2 were mixed with N2 at various molar fraction ratios to obtain Raman quantification factors (F12CO2 and F13CO2), which provide a theoretical basis for calculating the δ13C value. And the corresponding values were 0.523 (0 < C12CO2/CN2 < 2) and 1.11998 (0 < C13CO2/CN2 < 1.5) respectively. It has shown that the representative Raman peak area can be used for the determination of δ13C values within the relative errors range of 0.076% to 1.154% in 13CO2/12CO2 binary mixtures when F12CO2/F13CO2 is 0.466972625. In addition, measurement of δ13C values by Micro-Laser Raman analysis were carried out on natural CO2 gas from Shengli Oil-field at room temperature under different pressures. The δ13C values obtained by Micro-Laser Raman spectroscopy technology and Isotope Ratio Mass Spectrometry (IRMS) technology are in good agreement with each other, and the relative errors range of δ13C values is 1.232%-6.964%. This research provides a fundamental analysis tool for determining gas carbon isotope composition (δ13C values) quantitatively by using Micro-Laser Raman spectroscopy. Experiment of results demonstrates that this method has the potential for obtaining δ13C values in natural CO2 gas reservoirs.

  1. Effects of geomagnetic activity and atmospheric power variations on quantitative measures of brain activity: Replication of the Azerbaijani studies

    NASA Astrophysics Data System (ADS)

    Mulligan, Bryce P.; Hunter, Mathew D.; Persinger, Michael A.

    2010-04-01

    This study replicates and extends the observations by Babayev and Allahveriyeva that changes in right hemispheric electroencephalographic activity are correlated with increases in geomagnetic activity. During the geomagnetically quiet interface between solar cycle 23 and 24 quantitative electroencephalographic (QEEG) measurements were completed for normal young adults in three separate experiments involving about 120 samples over 1.5 years. The most consistent, moderate strength correlations occurred for the changes in power within the gamma and theta ranges over the right frontal lobe. Real-time measures of atmospheric power obtained from polar orbiting satellites showed similar effects. The preferential involvement of the right frontal lobe and the regions subject to its inhibition with environmental energetic changes are consistent with the behavioural correlations historically associated with these conditions. They include increased incidence of emotional lability, erroneous reconstruction of experiences, social confrontations, and unusual perceptions.

  2. Prediagnostic Smoking Is Associated with Binary and Quantitative Measures of ER Protein and ESR1 mRNA Expression in Breast Tumors.

    PubMed

    Butler, Eboneé N; Bensen, Jeannette T; Chen, Mengjie; Conway, Kathleen; Richardson, David B; Sun, Xuezheng; Geradts, Joseph; Olshan, Andrew F; Troester, Melissa A

    2018-01-01

    Background: Smoking is a possible risk factor for breast cancer and has been linked to increased risk of estrogen receptor-positive (ER + ) disease in some epidemiologic studies. It is unknown whether smoking has quantitative effects on ER expression. Methods: We examined relationships between smoking and ER expression from tumors of 1,888 women diagnosed with invasive breast cancer from a population-based study in North Carolina. ER expression was characterized using binary (±) and continuous measures for ER protein, ESR1 mRNA, and a multigene luminal score (LS) that serves as a measure of estrogen signaling in breast tumors. We used logistic and linear regression models to estimate temporal and dose-dependent associations between smoking and ER measures. Results: The odds of ER + , ESR1 + , and LS + tumors among current smokers (at the time of diagnosis), those who smoked 20 or more years, and those who smoked within 5 years of diagnosis were nearly double those of nonsmokers. Quantitative levels of ESR1 were highest among current smokers compared with never smokers overall [mean (log 2 ) = 9.2 vs. 8.7, P < 0.05] and among ER + cases; however, we did not observe associations between smoking measures and continuous ER protein expression. Conclusions: In relationship to breast cancer diagnosis, recent smoking was associated with higher odds of the ER + , ESR1 + , and LS + subtype. Current smoking was associated with elevated ESR1 mRNA levels and an elevated LS, but not with altered ER protein. Impact: A multigene LS and single-gene ESR1 mRNA may capture tumor changes associated with smoking. Cancer Epidemiol Biomarkers Prev; 27(1); 67-74. ©2017 AACR . ©2017 American Association for Cancer Research.

  3. The 6-minute walk test, motor function measure and quantitative thigh muscle MRI in Becker muscular dystrophy: A cross-sectional study.

    PubMed

    Fischer, Dirk; Hafner, Patricia; Rubino, Daniela; Schmid, Maurice; Neuhaus, Cornelia; Jung, Hans; Bieri, Oliver; Haas, Tanja; Gloor, Monika; Fischmann, Arne; Bonati, Ulrike

    2016-07-01

    Becker muscular dystrophy (BMD) has an incidence of 1 in 16 000 male births. This cross-sectional study investigated the relation between validated functional scores and quantitative MRI (qMRI) of thigh muscles in 20 ambulatory BMD patients, aged 18.3-60 years (mean 31.2; SD 11.1). Clinical assessments included the motor function measure (MFM) and its subscales, as well as timed function tests such as the 6-minute walk test (6MWT) and the timed 10-m run/walk test. Quantitative MRI of the thigh muscles included the mean fat fraction (MFF) using a 2-point Dixon (2-PD) technique, and transverse relaxation time (T2) measurements. The mean MFM value was 80.4%, SD 9.44 and the D1 subscore 54.5%, SD 19.9. The median 6MWT was 195m, IQR 160-330.2. The median 10-m run/walk test was 7.4 seconds, IQR 6.1-9.3. The mean fat fraction of the thigh muscles was 55.6%, SD 17.4%, mean T2 relaxation times of all muscles: 69.9 ms, SD 14.4. The flexors had the highest MFF and T2 relaxation times, followed by the extensors and the adductors. MFF and global T2 relaxation times were highly negatively correlated with the MFM total, D1-subscore and 6MWT, and positively correlated with the 10 m run/walk test time (p < 0.01). Age was not correlated with MFF, global T2 relaxation time or clinical assessments. Both MFF and T2 measures in the thigh muscle were well correlated with clinical function in BMD and may serve as a surrogate outcome measure in clinical trials. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Development of a Multi-Point Quantitation Method to Simultaneously Measure Enzymatic and Structural Components of the Clostridium thermocellum Cellulosome Protein Complex

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dykstra, Andrew B; St. Brice, Lois; Rodriguez, Jr., Miguel

    2014-01-01

    Clostridium thermocellum has emerged as a leading bioenergy-relevant microbe due to its ability to solubilize cellulose into carbohydrates, mediated by multi-component membrane-attached complexes termed cellulosomes. To probe microbial cellulose utilization rates, it is desirable to be able to measure the concentrations of saccharolytic enzymes and estimate the total amount of cellulosome present on a mass basis. Current cellulase determination methodologies involve labor-intensive purification procedures and only allow for indirect determination of abundance. We have developed a method using multiple reaction monitoring (MRM-MS) to simultaneously quantitate both enzymatic and structural components of the cellulosome protein complex in samples ranging in complexitymore » from purified cellulosomes to whole cell lysates, as an alternative to a previously-developed enzyme-linked immunosorbent assay (ELISA) method of cellulosome quantitation. The precision of the cellulosome mass concentration in technical replicates is better than 5% relative standard deviation for all samples, indicating high precision for determination of the mass concentration of cellulosome components.« less

  5. Portable smartphone based quantitative phase microscope

    NASA Astrophysics Data System (ADS)

    Meng, Xin; Tian, Xiaolin; Yu, Wei; Kong, Yan; Jiang, Zhilong; Liu, Fei; Xue, Liang; Liu, Cheng; Wang, Shouyu

    2018-01-01

    To realize portable device with high contrast imaging capability, we designed a quantitative phase microscope using transport of intensity equation method based on a smartphone. The whole system employs an objective and an eyepiece as imaging system and a cost-effective LED as illumination source. A 3-D printed cradle is used to align these components. Images of different focal planes are captured by manual focusing, followed by calculation of sample phase via a self-developed Android application. To validate its accuracy, we first tested the device by measuring a random phase plate with known phases, and then red blood cell smear, Pap smear, broad bean epidermis sections and monocot root were also measured to show its performance. Owing to its advantages as accuracy, high-contrast, cost-effective and portability, the portable smartphone based quantitative phase microscope is a promising tool which can be future adopted in remote healthcare and medical diagnosis.

  6. An evidence base for International Health Regulations: quantitative measurement of the impacts of epidemic disease on international trade.

    PubMed

    Kimball, A M; Wong, K Y; Taneda, K

    2005-12-01

    When cholera broke out in Mozambique, Kenya, Tanzania and Uganda in 1997, an urgent measure was filed with the Sanitary and Phytosanitary Committee of the World Trade Organization, by the European Union, citing the protection of human health, to limit imports of fish products. The authors analysed import data on specified products over time to quantify the trade impact of this measure. Using previous specific trade trends, the authors modelled expected trade flows and compared observed imports with expected imports to calculate the potential cost of lost trade. The conclusion of this analysis was that the impact of European restrictions on fish exports from Mozambique, Kenya, Tanzania and Uganda on the economies of these African countries was at least US dollar 332,217,415 for the years 1998 to 2002. Insights from such quantitative studies will be important in making policy choices under the revised International Health Regulations of the World Health Organization and should inform the discussion about the adoption of these regulations.

  7. Repeatability Assessment by ISO 11843-7 in Quantitative HPLC for Herbal Medicines.

    PubMed

    Chen, Liangmian; Kotani, Akira; Hakamata, Hideki; Tsutsumi, Risa; Hayashi, Yuzuru; Wang, Zhimin; Kusu, Fumiyo

    2015-01-01

    We have proposed an assessment methods to estimate the measurement relative standard deviation (RSD) of chromatographic peaks in quantitative HPLC for herbal medicines by the methodology of ISO 11843 Part 7 (ISO 11843-7:2012), which provides detection limits stochastically. In quantitative HPLC with UV detection (HPLC-UV) of Scutellaria Radix for the determination of baicalin, the measurement RSD of baicalin by ISO 11843-7:2012 stochastically was within a 95% confidence interval of the statistically obtained RSD by repetitive measurements (n = 6). Thus, our findings show that it is applicable for estimating of the repeatability of HPLC-UV for determining baicalin without repeated measurements. In addition, the allowable limit of the "System repeatability" in "Liquid Chromatography" regulated in a pharmacopoeia can be obtained by the present assessment method. Moreover, the present assessment method was also successfully applied to estimate the measurement RSDs of quantitative three-channel liquid chromatography with electrochemical detection (LC-3ECD) of Chrysanthemi Flos for determining caffeoylquinic acids and flavonoids. By the present repeatability assessment method, reliable measurement RSD was obtained stochastically, and the experimental time was remarkably reduced.

  8. Quantitative aspects of inductively coupled plasma mass spectrometry

    NASA Astrophysics Data System (ADS)

    Bulska, Ewa; Wagner, Barbara

    2016-10-01

    Accurate determination of elements in various kinds of samples is essential for many areas, including environmental science, medicine, as well as industry. Inductively coupled plasma mass spectrometry (ICP-MS) is a powerful tool enabling multi-elemental analysis of numerous matrices with high sensitivity and good precision. Various calibration approaches can be used to perform accurate quantitative measurements by ICP-MS. They include the use of pure standards, matrix-matched standards, or relevant certified reference materials, assuring traceability of the reported results. This review critically evaluates the advantages and limitations of different calibration approaches, which are used in quantitative analyses by ICP-MS. Examples of such analyses are provided. This article is part of the themed issue 'Quantitative mass spectrometry'.

  9. Quantitative measures of meniscus extrusion predict incident radiographic knee osteoarthritis--data from the Osteoarthritis Initiative.

    PubMed

    Emmanuel, K; Quinn, E; Niu, J; Guermazi, A; Roemer, F; Wirth, W; Eckstein, F; Felson, D

    2016-02-01

    To test the hypothesis that quantitative measures of meniscus extrusion predict incident radiographic knee osteoarthritis (KOA), prior to the advent of radiographic disease. 206 knees with incident radiographic KOA (Kellgren Lawrence Grade (KLG) 0 or 1 at baseline, developing KLG 2 or greater with a definite osteophyte and joint space narrowing (JSN) grade ≥1 by year 4) were matched to 232 control knees not developing incident KOA. Manual segmentation of the central five slices of the medial and lateral meniscus was performed on coronal 3T DESS MRI and quantitative meniscus position was determined. Cases and controls were compared using conditional logistic regression adjusting for age, sex, BMI, race and clinical site. Sensitivity analyses of early (year [Y] 1/2) and late (Y3/4) incidence was performed. Mean medial extrusion distance was significantly greater for incident compared to non-incident knees (1.56 mean ± 1.12 mm SD vs 1.29 ± 0.99 mm; +21%, P < 0.01), so was the percent extrusion area of the medial meniscus (25.8 ± 15.8% vs 22.0 ± 13.5%; +17%, P < 0.05). This finding was consistent for knees restricted to medial incidence. No significant differences were observed for the lateral meniscus in incident medial KOA, or for the tibial plateau coverage between incident and non-incident knees. Restricting the analysis to medial incident KOA at Y1/2 differences were attenuated, but reached significance for extrusion distance, whereas no significant differences were observed at incident KOA in Y3/4. Greater medial meniscus extrusion predicts incident radiographic KOA. Early onset KOA showed greater differences for meniscus position between incident and non-incident knees than late onset KOA. Copyright © 2015 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  10. Questionnaire-based person trip visualization and its integration to quantitative measurements in Myanmar

    NASA Astrophysics Data System (ADS)

    Kimijiama, S.; Nagai, M.

    2016-06-01

    With telecommunication development in Myanmar, person trip survey is supposed to shift from conversational questionnaire to GPS survey. Integration of both historical questionnaire data to GPS survey and visualizing them are very important to evaluate chronological trip changes with socio-economic and environmental events. The objectives of this paper are to: (a) visualize questionnaire-based person trip data, (b) compare the errors between questionnaire and GPS data sets with respect to sex and age and (c) assess the trip behaviour in time-series. Totally, 345 individual respondents were selected through random stratification to assess person trip using a questionnaire and GPS survey for each. Conversion of trip information such as a destination from the questionnaires was conducted by using GIS. The results show that errors between the two data sets in the number of trips, total trip distance and total trip duration are 25.5%, 33.2% and 37.2%, respectively. The smaller errors are found among working-age females mainly employed with the project-related activities generated by foreign investment. The trip distant was yearly increased. The study concluded that visualization of questionnaire-based person trip data and integrating them to current quantitative measurements are very useful to explore historical trip changes and understand impacts from socio-economic events.

  11. A new quantitative approach to measure perceived work-related stress in Italian employees.

    PubMed

    Cevenini, Gabriele; Fratini, Ilaria; Gambassi, Roberto

    2012-09-01

    We propose a method for a reliable quantitative measure of subjectively perceived occupational stress applicable in any company to enhance occupational safety and psychosocial health, to enable precise prevention policies and intervention and to improve work quality and efficiency. A suitable questionnaire was telephonically administered to a stratified sample of the whole Italian population of employees. Combined multivariate statistical methods, including principal component, cluster and discriminant analyses, were used to identify risk factors and to design a causal model for understanding work-related stress. The model explained the causal links of stress through employee perception of imbalance between job demands and resources for responding appropriately, by supplying a reliable U-shaped nonlinear stress index, expressed in terms of values of human systolic arterial pressure. Low, intermediate and high values indicated demotivation (or inefficiency), well-being and distress, respectively. Costs for stress-dependent productivity shortcomings were estimated to about 3.7% of national income from employment. The method identified useful structured information able to supply a simple and precise interpretation of employees' well-being and stress risk. Results could be compared with estimated national benchmarks to enable targeted intervention strategies to protect the health and safety of workers, and to reduce unproductive costs for firms.

  12. Weak-beam scanning transmission electron microscopy for quantitative dislocation density measurement in steels.

    PubMed

    Yoshida, Kenta; Shimodaira, Masaki; Toyama, Takeshi; Shimizu, Yasuo; Inoue, Koji; Yoshiie, Toshimasa; Milan, Konstantinovic J; Gerard, Robert; Nagai, Yasuyoshi

    2017-04-01

    To evaluate dislocations induced by neutron irradiation, we developed a weak-beam scanning transmission electron microscopy (WB-STEM) system by installing a novel beam selector, an annular detector, a high-speed CCD camera and an imaging filter in the camera chamber of a spherical aberration-corrected transmission electron microscope. The capabilities of the WB-STEM with respect to wide-view imaging, real-time diffraction monitoring and multi-contrast imaging are demonstrated using typical reactor pressure vessel steel that had been used in an European nuclear reactor for 30 years as a surveillance test piece with a fluence of 1.09 × 1020 neutrons cm-2. The quantitatively measured size distribution (average loop size = 3.6 ± 2.1 nm), number density of the dislocation loops (3.6 × 1022 m-3) and dislocation density (7.8 × 1013 m m-3) were carefully compared with the values obtained via conventional weak-beam transmission electron microscopy studies. In addition, cluster analysis using atom probe tomography (APT) further demonstrated the potential of the WB-STEM for correlative electron tomography/APT experiments. © The Author 2017. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  13. Quantitative measurements of localized density variations in cylindrical tablets using X-ray microtomography.

    PubMed

    Busignies, Virginie; Leclerc, Bernard; Porion, Patrice; Evesque, Pierre; Couarraze, Guy; Tchoreloff, Pierre

    2006-08-01

    Direct compaction is a complex process that results in a density distribution inside the tablets which is often heterogeneous. Therefore, the density variations may affect the compact properties. A quantitative analysis of this phenomenon is still lacking. Recently, X-ray microtomography has been successfully used in pharmaceutical development to study qualitatively the impact of tablet shape and break-line in the density of pharmaceutical tablets. In this study, we evaluate the density profile in microcrystalline cellulose (Vivapur 12) compacts obtained at different mean porosity (ranging from 7.7% to 33.5%) using X-ray tomography technique. First, the validity of the Beer-Lambert law is studied. Then, density calibration is performed and density maps of cylindrical tablets are obtained and visualized using a process with colour-scale calibration plot which is explained. As expected, important heterogeneity in density is observed and quantified. The higher densities in peripheral region were particularly investigated and appraised in regard to the lower densities observed in the middle of the tablet. The results also underlined that in the case of pharmaceutical tablets, it is important to differentiate the mechanical properties representative of the total volume tablet and the mechanical properties that only characterize the tablet surface like the Brinell hardness measurements.

  14. Measuring the Refractive Index of Bovine Corneal Stromal Cells Using Quantitative Phase Imaging

    PubMed Central

    Gardner, Steven J.; White, Nick; Albon, Julie; Knupp, Carlo; Kamma-Lorger, Christina S.; Meek, Keith M.

    2015-01-01

    The cornea is the primary refractive lens in the eye and transmits >90% of incident visible light. It has been suggested that the development of postoperative corneal haze could be due to an increase in light scattering from activated corneal stromal cells. Quiescent keratocytes are thought to produce crystallins that match the refractive index of their cytoplasm to the surrounding extracellular material, reducing the amount of light scattering. To test this, we measured the refractive index (RI) of bovine corneal stromal cells, using quantitative phase imaging of live cells in vitro, together with confocal microscopy. The RI of quiescent keratocytes (RI = 1.381 ± 0.004) matched the surrounding matrix, thus supporting the hypothesis that keratocyte cytoplasm does not scatter light in the normal cornea. We also observed that the RI drops after keratocyte activation (RI = 1.365 ± 0.003), leading to a mismatch with the surrounding intercellular matrix. Theoretical scattering models showed that this mismatch would reduce light transmission in the cornea. We conclude that corneal transparency depends on the matching of refractive indices between quiescent keratocytes and the surrounding tissue, and that after surgery or wounding, the resulting RI mismatch between the activated cells and their surrounds significantly contributes to light scattering. PMID:26488650

  15. Quantitative Laser-Saturated Fluorescence Measurements of Nitric Oxide in a Heptane Spray Flame

    NASA Technical Reports Server (NTRS)

    Cooper, Clayton S.; Laurendeau, Normand M.; Lee, Chi (Technical Monitor)

    1997-01-01

    We report spatially resolved laser-saturated fluorescence measurements of NO concentration in a pre-heated, lean-direct injection (LDI) spray flame at atmospheric pressure. The spray is produced by a hollow-cone, pressure-atomized nozzle supplied with liquid heptane. NO is excited via the Q2(26.5) transition of the gamma(0,0) band. Detection is performed in a 2-nm region centered on the gamma(0,1) band. Because of the relatively close spectral spacing between the excitation (226 nm) and detection wavelengths (236 nm), the gamma(0,1) band of NO cannot be isolated from the spectral wings of the Mie scattering signal produced by the spray. To account for the resulting superposition of the fluorescence and scattering signals, a background subtraction method has been developed that utilizes a nearby non-resonant wavelength. Excitation scans have been performed to locate the optimum off-line wavelength. Detection scans have been performed at problematic locations in the flame to determine possible fluorescence interferences from UHCs and PAHs at both the on-line and off-line excitation wavelengths. Quantitative radial NO profiles are presented and analyzed so as to better understand the operation of lean-direct injectors for gas turbine combustors.

  16. 3D OCT imaging in clinical settings: toward quantitative measurements of retinal structures

    NASA Astrophysics Data System (ADS)

    Zawadzki, Robert J.; Fuller, Alfred R.; Zhao, Mingtao; Wiley, David F.; Choi, Stacey S.; Bower, Bradley A.; Hamann, Bernd; Izatt, Joseph A.; Werner, John S.

    2006-02-01

    The acquisition speed of current FD-OCT (Fourier Domain - Optical Coherence Tomography) instruments allows rapid screening of three-dimensional (3D) volumes of human retinas in clinical settings. To take advantage of this ability requires software used by physicians to be capable of displaying and accessing volumetric data as well as supporting post processing in order to access important quantitative information such as thickness maps and segmented volumes. We describe our clinical FD-OCT system used to acquire 3D data from the human retina over the macula and optic nerve head. B-scans are registered to remove motion artifacts and post-processed with customized 3D visualization and analysis software. Our analysis software includes standard 3D visualization techniques along with a machine learning support vector machine (SVM) algorithm that allows a user to semi-automatically segment different retinal structures and layers. Our program makes possible measurements of the retinal layer thickness as well as volumes of structures of interest, despite the presence of noise and structural deformations associated with retinal pathology. Our software has been tested successfully in clinical settings for its efficacy in assessing 3D retinal structures in healthy as well as diseased cases. Our tool facilitates diagnosis and treatment monitoring of retinal diseases.

  17. Quantitative Susceptibility Mapping and R2* Measured Changes during White Matter Lesion Development in Multiple Sclerosis: Myelin Breakdown, Myelin Debris Degradation and Removal, and Iron Accumulation.

    PubMed

    Zhang, Y; Gauthier, S A; Gupta, A; Chen, W; Comunale, J; Chiang, G C-Y; Zhou, D; Askin, G; Zhu, W; Pitt, D; Wang, Y

    2016-09-01

    Quantitative susceptibility mapping and R2* are sensitive to myelin and iron changes in multiple sclerosis lesions. This study was designed to characterize lesion changes on quantitative susceptibility mapping and R2* at various gadolinium-enhancement stages. This study included 64 patients with MS with different enhancing patterns in white matter lesions: nodular, shell-like, nonenhancing < 1 year old, and nonenhancing 1-3 years old. These represent acute, late acute, early chronic, and late chronic lesions, respectively. Susceptibility values measured on quantitative susceptibility mapping and R2* values were compared among the 4 lesion types. Their differences were assessed with a generalized estimating equation, controlling for Expanded Disability Status Scale score, age, and disease duration. We analyzed 203 lesions: 80 were nodular-enhancing, of which 77 (96.2%) were isointense on quantitative susceptibility mapping; 33 were shell-enhancing, of which 30 (90.9%) were hyperintense on quantitative susceptibility mapping; and 49 were nonenhancing lesions < 1 year old and 41 were nonenhancing lesions 1-3 years old, all of which were hyperintense on quantitative susceptibility mapping. Their relative susceptibility/R2* values were 0.5 ± 4.4 parts per billion/-5.6 ± 2.9 Hz, 10.2 ± 5.4 parts per billion/-8.0 ± 2.6 Hz, 20.2 ± 7.8 parts per billion/-3.1 ± 2.3 Hz, and 33.2 ± 8.2 parts per billion/-2.0 ± 2.6 Hz, respectively, and were significantly different (P < .005). Early active MS lesions with nodular enhancement show R2* decrease but no quantitative susceptibility mapping change, reflecting myelin breakdown; late active lesions with peripheral enhancement show R2* decrease and quantitative susceptibility mapping increase in the lesion center, reflecting further degradation and removal of myelin debris; and early or late chronic nonenhancing lesions show both quantitative susceptibility mapping and R2* increase, reflecting iron accumulation. © 2016 by

  18. Quantitative infrared absorption cross sections of isoprene for atmospheric measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brauer, Carolyn S.; Blake, Thomas A.; Guenther, Alex B.

    2014-11-19

    The OH- and O 3- initiated oxidations of isoprene, which is one of the primary volatile organic compounds produced by vegetation, are a major source of atmospheric formaldehyde and other oxygenated organics, yet little quantitative IR data exists for isoprene. We thus report absorption coefficients and integrated band intensities for isoprene in the 600 - 6500 cm -1 region. The pressure-broadened (1 atmosphere N 2) spectra were recorded at 278, 298 and 323 K in a 19.96 cm path length cell at 0.112 cm -1 resolution, using a Bruker 66V FTIR. Composite spectra are derived from a minimum of sevenmore » pressures at each temperature.« less

  19. Quantitative Evaluation of Musical Scale Tunings

    ERIC Educational Resources Information Center

    Hall, Donald E.

    1974-01-01

    The acoustical and mathematical basis of the problem of tuning the twelve-tone chromatic scale is reviewed. A quantitative measurement showing how well any tuning succeeds in providing just intonation for any specific piece of music is explained and applied to musical examples using a simple computer program. (DT)

  20. Quantitative Species Measurements in Microgravity Combustion Flames

    NASA Technical Reports Server (NTRS)

    Silver, Joel A.; Wood, William R.; Chen, Shin-Juh; Dahm, Werner J. A.; Piltch, Nancy D.

    2001-01-01

    Flame-vortex interactions are canonical configurations that can be used to study the underlying processes occurring in complicated turbulent reacting flows. The elegant simplicity of the flame-vortex interaction permits the study of these complex interactions under relatively controllable experimental configurations, in contrast to direct measurements in turbulent flames. The ability to measure and model the fundamental phenomena that occur in a turbulent flame, but with time and spatial scales which are amenable to our diagnostics, permits significant improvements in the understanding of turbulent combustion under both normal and reduced gravity conditions. In this paper, we report absolute mole fraction measurements of methane in a reacting vortex ring. These microgravity experiments are performed in the 2.2-sec drop tower at NASA Glenn Research Center. In collaboration with Drs. Chen and Dahm at the University of Michigan, measured methane absorbances are incorporated into a new model from which the temperature and concentrations of all major gases in the flame can be determined at all positions and times in the development of the vortex ring. This is the first demonstration of the ITAC (Iterative Temperature with Assumed Chemistry) approach, and the results of these computations and analyses are presented in a companion paper by Dahm and Chen at this Workshop. We believe that the ITAC approach will become a powerful tool in understanding a wide variety of combustion flames under both equilibrium and non-equilibrium conditions.