Sample records for quantitative blood cultures

  1. Quantitative interpretations of Visible-NIR reflectance spectra of blood.

    PubMed

    Serebrennikova, Yulia M; Smith, Jennifer M; Huffman, Debra E; Leparc, German F; García-Rubio, Luis H

    2008-10-27

    This paper illustrates the implementation of a new theoretical model for rapid quantitative analysis of the Vis-NIR diffuse reflectance spectra of blood cultures. This new model is based on the photon diffusion theory and Mie scattering theory that have been formulated to account for multiple scattering populations and absorptive components. This study stresses the significance of the thorough solution of the scattering and absorption problem in order to accurately resolve for optically relevant parameters of blood culture components. With advantages of being calibration-free and computationally fast, the new model has two basic requirements. First, wavelength-dependent refractive indices of the basic chemical constituents of blood culture components are needed. Second, multi-wavelength measurements or at least the measurements of characteristic wavelengths equal to the degrees of freedom, i.e. number of optically relevant parameters, of blood culture system are required. The blood culture analysis model was tested with a large number of diffuse reflectance spectra of blood culture samples characterized by an extensive range of the relevant parameters.

  2. Diagnostic accuracy of semi-quantitative and quantitative culture techniques for the diagnosis of catheter-related infections in newborns and molecular typing of isolated microorganisms.

    PubMed

    Riboli, Danilo Flávio Moraes; Lyra, João César; Silva, Eliane Pessoa; Valadão, Luisa Leite; Bentlin, Maria Regina; Corrente, José Eduardo; Rugolo, Ligia Maria Suppo de Souza; da Cunha, Maria de Lourdes Ribeiro de Souza

    2014-05-22

    Catheter-related bloodstream infections (CR-BSIs) have become the most common cause of healthcare-associated bloodstream infections in neonatal intensive care units (ICUs). Microbiological evidence implicating catheters as the source of bloodstream infection is necessary to establish the diagnosis of CR-BSIs. Semi-quantitative culture is used to determine the presence of microorganisms on the external catheter surface, whereas quantitative culture also isolates microorganisms present inside the catheter. The main objective of this study was to determine the sensitivity and specificity of these two techniques for the diagnosis of CR-BSIs in newborns from a neonatal ICU. In addition, PFGE was used for similarity analysis of the microorganisms isolated from catheters and blood cultures. Semi-quantitative and quantitative methods were used for the culture of catheter tips obtained from newborns. Strains isolated from catheter tips and blood cultures which exhibited the same antimicrobial susceptibility profile were included in the study as positive cases of CR-BSI. PFGE of the microorganisms isolated from catheters and blood cultures was performed for similarity analysis and detection of clones in the ICU. A total of 584 catheter tips from 399 patients seen between November 2005 and June 2012 were analyzed. Twenty-nine cases of CR-BSI were confirmed. Coagulase-negative staphylococci (CoNS) were the most frequently isolated microorganisms, including S. epidermidis as the most prevalent species (65.5%), followed by S. haemolyticus (10.3%), yeasts (10.3%), K. pneumoniae (6.9%), S. aureus (3.4%), and E. coli (3.4%). The sensitivity of the semi-quantitative and quantitative techniques was 72.7% and 59.3%, respectively, and specificity was 95.7% and 94.4%. The diagnosis of CR-BSIs based on PFGE analysis of similarity between strains isolated from catheter tips and blood cultures showed 82.6% sensitivity and 100% specificity. The semi-quantitative culture method showed higher

  3. [Blood stream infection and blood culture--"progress" and "blind" in blood culture testing].

    PubMed

    Kobayashi, Intetsu

    2005-04-01

    We have investigated various types of blood culture bottles which are mainly used at present and posed problems present in the blood culture bottles. First, there are differences between resin and ecosorb in the ability to adsorb and inactivate antibiotics in the blood. Second, the delay in placing the bottle (into which blood was inoculated) to the automatic instrument (delay in the start of incubation) greatly affects the automatic detection by BACTEC system and shows false negatives. Third, when the same blood is incubated in plural bottles (aerobic and anaerobic bottles), the differences among the detected organisms in the number are comparatively high, i.e., about 40%. In addition, there are differences among the organisms in the number of days required for the detection of the organisms. In this case, the detected organisms are clearly different in many cases. The technology of blood culture has been progressed remarkably. However, the efficiency of utilization of automatic instruments for diagnosis of infection depends greatly on the ability of laboratory technicians.

  4. Evaluation of Verigene Blood Culture Test Systems for Rapid Identification of Positive Blood Cultures.

    PubMed

    Kim, Jae-Seok; Kang, Go-Eun; Kim, Han-Sung; Kim, Hyun Soo; Song, Wonkeun; Lee, Kyu Man

    2016-01-01

    The performance of molecular tests using the Verigene Gram-Positive and Gram-Negative Blood Culture nucleic acid tests (BC-GP and BC-GN, resp.; Naosphere, Northbrook, IL, USA) was evaluated for the identification of microorganisms detected from blood cultures. Ninety-nine blood cultures containing Gram-positive bacteria and 150 containing Gram-negative bacteria were analyzed using the BC-GP and BC-GN assays, respectively. Blood cultures were performed using the Bactec blood culture system (BD Diagnostic Systems, Franklin Lakes, NJ, USA) and conventional identification and antibiotic-susceptibility tests were performed using a MicroScan system (Siemens, West Sacramento, CA, USA). When a single strain of bacteria was isolated from the blood culture, Verigene assays correctly identified 97.9% (94/96) of Gram-positive bacteria and 93.8% (137/146) of Gram-negative bacteria. Resistance genes mecA and vanA were correctly detected by the BC-GP assay, while the extended-spectrum β-lactamase CTX-M and the carbapenemase OXA resistance gene were detected from 30 cases cultures by the BC-GN assay. The BC-GP and BC-GN assays showed high agreement with conventional identification and susceptibility tests. These tests are useful for rapid identification of microorganisms and the detection of clinically important resistance genes from positive Bactec blood cultures.

  5. Evaluation of the usefulness of a quantitative blood culture in the diagnosis of catheter-related bloodstream infection: Comparative analysis of two periods (2002 and 2012).

    PubMed

    Planes, Anna Maria; Calleja, Raquel; Bernet, Albert; Campins-Martí, Magda; Almirante, Benito; Pumarola, Tomàs; Fernández-Hidalgo, Núria

    2016-10-01

    A retrospective study was conducted to investigate the usefulness of systematic quantitative blood culture (QBC) in the diagnosis of catheter-related bloodstream infection (CRBSI) during two 1-year periods (2002 and 2012). The study included all QBC requests sent to the microbiology laboratory for suspected CRBSI in adults (≥18 years) with any type of intravascular catheter (IVC). Based on a ratio of ≥4:1CFU/mL of the same microorganism between IVC blood culture from any lumen and peripheral blood culture, 5 diagnostic groups were defined: confirmed or probable CRBSI, primary BSI, other focus of infection, and colonization. In total, 4521 QBCs were evaluated; 24% positive in 2002 and 16% in 2012 (P<0.0001). There were 243 episodes of suspected CRBSI (101 in 2002 and 142 in 2012). Confirmed CRBSI episodes were higher in 2002 than 2012 (56% vs 34%) (P<0.0001), whereas colonization episodes were lower (18% vs 38%) (P=0.0006). Gram-positive cocci decrease in 2012 relative to 2002 (56% vs 79.7%) (P=0.022). Almost one-third (32%) of confirmed CRBSI would have been missed if blood from all catheter lumens had not been cultured. QBC is a useful method for diagnosing CRBSI. Blood samples from all catheter lumens must be cultured to avoid missing around one-third of CRBSI diagnoses. Copyright © 2015 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  6. Blood culture bottles are superior to conventional media for vitreous culture.

    PubMed

    Thariya, Patsuda; Yospaiboon, Yosanan; Sinawat, Suthasinee; Sanguansak, Thuss; Bhoomibunchoo, Chavakij; Laovirojjanakul, Wipada

    2016-08-01

    To compare blood culture bottles and conventional media for the vitreous culture in patients with clinically suspected infectious endophthalmitis. Retrospective comparative study at KKU Eye Center, Khon Kaen University. There were 342 patients with clinically suspected infectious endophthalmitis participated in the study. The vitreous specimens were inoculated in both blood culture bottles and on conventional culture media (blood agar, MacConkey agar, chocolate agar, Sabouraud dextrose agar and thioglycolate broth). The number of positive culture yields in both blood culture bottles and conventional media. Positive culture yields in both methods were found in 151 eyes (49.5%). There were 136 of 151 eyes (90.1%) with positive culture in blood culture bottles, whereas 99 of 151 eyes (65.6%) yielded positive cultures in conventional media. These findings were different with a statistical significance (P < 0.00001) and an odds ratio of 3.47 (95% confidence interval 1.92, 6.63). A combination of blood culture bottles and conventional media improved the yield. Blood culture bottles are superior to conventional media for vitreous culture in clinically suspected infectious endophthalmitis. Vitreous culture using blood culture bottles should be recommended as the primary method for microbiological diagnosis. A combination of both methods further improves the positive culture yield. © 2016 Royal Australian and New Zealand College of Ophthalmologists.

  7. Comparison of EBV DNA viral load in whole blood, plasma, B-cells and B-cell culture supernatant.

    PubMed

    Ouedraogo, David Eric; Bollore, Karine; Viljoen, Johannes; Foulongne, Vincent; Reynes, Jacques; Cartron, Guillaume; Vendrell, Jean-Pierre; Van de Perre, Philippe; Tuaillon, Edouard

    2014-05-01

    Epstein-Barr virus (EBV) genome quantitation in whole blood is used widely for therapeutic monitoring of EBV-associated disorders in immunosuppressed individuals and in patients with EBV-associated lymphoma. However, the most appropriate biological material to be used for EBV DNA quantitation remains a subject of debate. This study compare the detection rate and levels of EBV DNA from whole blood, plasma, enriched B-cells, and B-cell short-term culture supernatant using quantitative real-time PCR. Samples were collected from 33 subjects with either HIV infection or B-cell lymphoma. Overall, EBV DNA was detected in 100% of enriched B-cell samples, in 82% of B-cell culture supernatants, in 57% of plasma, and 42% of whole blood samples. A significant correlation for EBV viral load was found between enriched B-cell and B-cell culture supernatant material (ρ = 0.92; P < 0.0001), but no significant correlation existed between EBV DNA levels in whole blood and enriched B-cells (ρ = -0.02; P = 0.89), whole blood and plasma (ρ = 0.24; P = 0.24), or enriched B-cells and plasma (ρ = 0.08; P = 0.77). Testing of enriched B-cells appeared to be the most sensitive method for detection of EBV DNA as well as for exploration of the cellular reservoir. Quantitation of EBV DNA in plasma and B-cell culture supernatant may be of interest to assess EBV reactivation dynamics and response to treatment as well as to decipher EBV host-pathogen interactions in various clinical scenarios. © 2013 Wiley Periodicals, Inc.

  8. Performance of Gram staining on blood cultures flagged negative by an automated blood culture system.

    PubMed

    Peretz, A; Isakovich, N; Pastukh, N; Koifman, A; Glyatman, T; Brodsky, D

    2015-08-01

    Blood is one of the most important specimens sent to a microbiology laboratory for culture. Most blood cultures are incubated for 5-7 days, except in cases where there is a suspicion of infection caused by microorganisms that proliferate slowly, or infections expressed by a small number of bacteria in the bloodstream. Therefore, at the end of incubation, misidentification of positive cultures and false-negative results are a real possibility. The aim of this work was to perform a confirmation by Gram staining of the lack of any microorganisms in blood cultures that were identified as negative by the BACTEC™ FX system at the end of incubation. All bottles defined as negative by the BACTEC FX system were Gram-stained using an automatic device and inoculated on solid growth media. In our work, 15 cultures that were defined as negative by the BACTEC FX system at the end of the incubation were found to contain microorganisms when Gram-stained. The main characteristic of most bacteria and fungi growing in the culture bottles that were defined as negative was slow growth. This finding raises a problematic issue concerning the need to perform Gram staining of all blood cultures, which could overload the routine laboratory work, especially laboratories serving large medical centers and receiving a large number of blood cultures.

  9. Blood culture

    MedlinePlus

    ... into (contaminating) the blood sample and causing a false-positive result (see below). The sample is sent to a laboratory. There, it is placed in a special dish (culture). It is then watched to see if bacteria ...

  10. Laboratory Workflow Analysis of Culture of Periprosthetic Tissues in Blood Culture Bottles.

    PubMed

    Peel, Trisha N; Sedarski, John A; Dylla, Brenda L; Shannon, Samantha K; Amirahmadi, Fazlollaah; Hughes, John G; Cheng, Allen C; Patel, Robin

    2017-09-01

    Culture of periprosthetic tissue specimens in blood culture bottles is more sensitive than conventional techniques, but the impact on laboratory workflow has yet to be addressed. Herein, we examined the impact of culture of periprosthetic tissues in blood culture bottles on laboratory workflow and cost. The workflow was process mapped, decision tree models were constructed using probabilities of positive and negative cultures drawn from our published study (T. N. Peel, B. L. Dylla, J. G. Hughes, D. T. Lynch, K. E. Greenwood-Quaintance, A. C. Cheng, J. N. Mandrekar, and R. Patel, mBio 7:e01776-15, 2016, https://doi.org/10.1128/mBio.01776-15), and the processing times and resource costs from the laboratory staff time viewpoint were used to compare periprosthetic tissues culture processes using conventional techniques with culture in blood culture bottles. Sensitivity analysis was performed using various rates of positive cultures. Annualized labor savings were estimated based on salary costs from the U.S. Labor Bureau for Laboratory staff. The model demonstrated a 60.1% reduction in mean total staff time with the adoption of tissue inoculation into blood culture bottles compared to conventional techniques (mean ± standard deviation, 30.7 ± 27.6 versus 77.0 ± 35.3 h per month, respectively; P < 0.001). The estimated annualized labor cost savings of culture using blood culture bottles was $10,876.83 (±$337.16). Sensitivity analysis was performed using various rates of culture positivity (5 to 50%). Culture in blood culture bottles was cost-effective, based on the estimated labor cost savings of $2,132.71 for each percent increase in test accuracy. In conclusion, culture of periprosthetic tissue in blood culture bottles is not only more accurate than but is also cost-saving compared to conventional culture methods. Copyright © 2017 American Society for Microbiology.

  11. Using Popular Culture to Teach Quantitative Reasoning

    ERIC Educational Resources Information Center

    Hillyard, Cinnamon

    2007-01-01

    Popular culture provides many opportunities to develop quantitative reasoning. This article describes a junior-level, interdisciplinary, quantitative reasoning course that uses examples from movies, cartoons, television, magazine advertisements, and children's literature. Some benefits from and cautions to using popular culture to teach…

  12. Quantitative photoacoustic characterization of blood clot in blood: A mechanobiological assessment through spectral information

    NASA Astrophysics Data System (ADS)

    Biswas, Deblina; Vasudevan, Srivathsan; Chen, George C. K.; Sharma, Norman

    2017-02-01

    Formation of blood clots, called thrombus, can happen due to hyper-coagulation of blood. Thrombi, while moving through blood vessels can impede blood flow, an important criterion for many critical diseases like deep vein thrombosis and heart attacks. Understanding mechanical properties of clot formation is vital for assessment of severity of thrombosis and proper treatment. However, biomechanics of thrombus is less known to clinicians and not very well investigated. Photoacoustic (PA) spectral response, a non-invasive technique, is proposed to investigate the mechanism of formation of blood clots through elasticity and also differentiate clots from blood. Distinct shift (increase in frequency) of the PA response dominant frequency during clot formation is reported. In addition, quantitative differentiation of blood clots from blood has been achieved through parameters like dominant frequency and spectral energy of PA spectral response. Nearly twofold increases in dominant frequency in blood clots compared to blood were found in the PA spectral response. Significant changes in energy also help in quantitatively differentiating clots from blood, in the blood. Our results reveal that increase in density during clot formation is reflected in the PA spectral response, a significant step towards understanding the mechanobiology of thrombus formation. Hence, the proposed tool, in addition to detecting thrombus formation, could reveal mechanical properties of the sample through quantitative photoacoustic spectral parameters.

  13. Quantitative influence of risk factors on blood glucose level.

    PubMed

    Chen, Songjing; Luo, Senlin; Pan, Limin; Zhang, Tiemei; Han, Longfei; Zhao, Haixiu

    2014-01-01

    The aim of this study is to quantitatively analyze the influence of risk factors on the blood glucose level, and to provide theory basis for understanding the characteristics of blood glucose change and confirming the intervention index for type 2 diabetes. The quantitative method is proposed to analyze the influence of risk factors on blood glucose using back propagation (BP) neural network. Ten risk factors are screened first. Then the cohort is divided into nine groups by gender and age. According to the minimum error principle, nine BP models are trained respectively. The quantitative values of the influence of different risk factors on the blood glucose change can be obtained by sensitivity calculation. The experiment results indicate that weight is the leading cause of blood glucose change (0.2449). The second factors are cholesterol, age and triglyceride. The total ratio of these four factors reaches to 77% of the nine screened risk factors. And the sensitivity sequences can provide judgment method for individual intervention. This method can be applied to risk factors quantitative analysis of other diseases and potentially used for clinical practitioners to identify high risk populations for type 2 diabetes as well as other disease.

  14. Quantitative blood group typing using surface plasmon resonance.

    PubMed

    Then, Whui Lyn; Aguilar, Marie-Isabel; Garnier, Gil

    2015-11-15

    The accurate and reliable typing of blood groups is essential prior to blood transfusion. While current blood typing methods are well established, results are subjective and heavily reliant on analysis by trained personnel. Techniques for quantifying blood group antibody-antigen interactions are also very limited. Many biosensing systems rely on surface plasmon resonance (SPR) detection to quantify biomolecular interactions. While SPR has been widely used for characterizing antibody-antigen interactions, measuring antibody interactions with whole cells is significantly less common. Previous studies utilized SPR for blood group antigen detection, however, showed poor regeneration causing loss of functionality after a single use. In this study, a fully regenerable, multi-functional platform for quantitative blood group typing via SPR detection is achieved by immobilizing anti-human IgG antibody to the sensor surface, which binds to the Fc region of human IgG antibodies. The surface becomes an interchangeable platform capable of quantifying the blood group interactions between red blood cells (RBCs) and IgG antibodies. As with indirect antiglobulin tests (IAT), which use IgG antibodies for detection, IgG antibodies are initially incubated with RBCs. This facilitates binding to the immobilized monolayer and allows for quantitative blood group detection. Using the D-antigen as an example, a clear distinction between positive (>500 RU) and negative (<100 RU) RBCs is achieved using anti-D IgG. Complete regeneration of the anti-human IgG surface is also successful, showing negligible degradation of the surface after more than 100 regenerations. This novel approach is validated with human-sourced whole blood samples to demonstrate an interesting alternative for quantitative blood grouping using SPR analysis. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  15. Leadership and Culture-Building in Schools: Quantitative and Qualitative Understandings.

    ERIC Educational Resources Information Center

    Sashkin, Marshall; Sashkin, Molly G.

    Understanding effective school leadership as a function of culture building through quantitative and qualitative analyses is the purpose of this paper. The two-part quantitative phase of the research focused on statistical measures of culture and leadership behavior directed toward culture building in the school. The first quantitative part…

  16. False no-growth blood cultures in pneumococcal pneumonia.

    PubMed Central

    Adeniyi-Jones, C C; Stevens, D L; Rasquinha, E S

    1980-01-01

    The growth of Streptococcus pneumoniae in commercial media containing 14C-labeled substrates was studied experimentally; the results of blood cultures that were positive for S. pneumoniae over a 14-month period were analyzed to explain no-growth but radiometrically positive blood cultures from four patients with clinically diagnosed pneumococcal pneumonia. The growth of S. pneumonoiae in aerobic blood culture vials resulted in a chocolate color in the medium. S. pneumoniae grew rapidly in both aerobic and anaerobic media, but 14CO2 evolved from the metabolism of the labeled substrates was detected only in the aerobic culture vials. Radiometric detection lagged behind growth of the organisms and was accompanied by visual changes in the media. By 24 h, the viability of the culture was on the decline; radiometric readings remained positive even when the culture had died. PMID:7419708

  17. Neonatal blood cultures: effect of delayed entry into the blood culture machine and bacterial concentration on the time to positive growth in a simulated model.

    PubMed

    Jardine, Luke Anthony; Sturgess, Barbara Ruth; Inglis, Garry Donald Trevor; Davies, Mark William

    2009-04-01

    To determine if: time from blood culture inoculation to positive growth (total time to positive) and time from blood culture machine entry to positive growth (machine time to positive) is altered by delayed entry into the automated blood culture machine, and if the total time to positive differs by the concentration of organisms inoculated into blood culture bottles. Staphylococcus epidermidis, Escherichia coli and group B beta-haemolytic streptococci were chosen as clinically significant representative organisms. Two concentrations (> or =10 colony-forming units per millilitre and <1 colony-forming units per millilitre) were inoculated into PEDS BacT/Alert blood culture bottles and randomly allocated to one of three delayed automated blood culture machine entry times (30 min/8.5 h/15.5 h). For all organisms at all concentrations, except the Staphylococcus epidermidis, the machine time to positive was significantly decreased by delayed entry. For all organisms at all concentrations, the mean total time to positive significantly increased with increasing delayed entry into the blood culture machine. Higher concentrations of group B beta-haemolytic streptococci and Escherichia coli grew significantly faster than lower concentrations. Bacterial growth in inoculated bottles, stored at room temperature, continues although at a slower rate than in those blood culture bottles immediately entered into the machine. If a blood culture specimen has been stored at room temperature for greater than 15.5 h, the currently allowed safety margin of 36 h (before declaring a result negative) may be insufficient.

  18. Blood culture results from healthy captive and free-ranging elasmobranchs.

    PubMed

    Mylniczenko, Natalie D; Harris, Brigita; Wilborn, Rachel E; Young, Forrest A

    2007-09-01

    Blood culture is a diagnostic tool used in confirming bacterial disease in teleostean and elasmobranch fishes. Unlike teleosts, elasmobranchs have a normal microflora in multiple organs, but their blood has generally been considered to be sterile. In regular exams of elasmobranchs conducted at a public aquarium, occasional blood samples have tested positive on culture. This finding prompted a blood culture survey of healthy captive and wild elasmobranchs (sharks and stingrays), which showed that 26.7% of all animals were positive. Stingrays alone showed a 50% occurrence of positive blood cultures, although the total number of animals was low and freshwater species were included in this number. When elasmobranchs other than stingrays were evaluated according to metabolic category, pelagic animals had a higher percentage of positive cultures than nonpelagic animals (38.7% versus 13.9%). These results indicate that a single positive blood culture without other corroborating diagnostics is not sufficient to confirm septicemia in elasmobranchs.

  19. [Quantitative determination of blood regurgitation via the mitral valve].

    PubMed

    Sandrikov, V A

    1981-11-01

    A method of quantitative determination of blood regurgitation through the mitral valve is considered. Verification experiment on 5 animals with the determination of correlation coefficient of true and predicted regurgitation has shown it to be 0.855 on the average. Besides, observations were undertaken on 621 patient with varying pathology of the heart. A quantitative characteristics of blood regurgitation in patients with mitral defects is given. The method can be used not only under operation conditions, but also in catheterization of the cardiac cavities without administering of an opaque substance.

  20. Quantitative and qualitative research across cultures and languages: cultural metrics and their application.

    PubMed

    Wagner, Wolfgang; Hansen, Karolina; Kronberger, Nicole

    2014-12-01

    Growing globalisation of the world draws attention to cultural differences between people from different countries or from different cultures within the countries. Notwithstanding the diversity of people's worldviews, current cross-cultural research still faces the challenge of how to avoid ethnocentrism; comparing Western-driven phenomena with like variables across countries without checking their conceptual equivalence clearly is highly problematic. In the present article we argue that simple comparison of measurements (in the quantitative domain) or of semantic interpretations (in the qualitative domain) across cultures easily leads to inadequate results. Questionnaire items or text produced in interviews or via open-ended questions have culturally laden meanings and cannot be mapped onto the same semantic metric. We call the culture-specific space and relationship between variables or meanings a 'cultural metric', that is a set of notions that are inter-related and that mutually specify each other's meaning. We illustrate the problems and their possible solutions with examples from quantitative and qualitative research. The suggested methods allow to respect the semantic space of notions in cultures and language groups and the resulting similarities or differences between cultures can be better understood and interpreted.

  1. Doing it right the first time: quality improvement and the contaminant blood culture.

    PubMed

    Weinbaum, F I; Lavie, S; Danek, M; Sixsmith, D; Heinrich, G F; Mills, S S

    1997-03-01

    The aim of the project was to determine whether the rate of contaminant blood cultures could be reduced by using a team of dedicated phlebotomists. Comparisons were made between adult patients requiring blood cultures for suspected bacteremia on medical and surgical units before and after the introduction and withdrawal of a dedicated blood culture team. The results showed that a significant reduction in the contaminant blood culture rate was achieved by the blood culture team (P < 0.001; chi(2) test). Therefore, in our experience, the rate of contaminant blood cultures can be reduced in a teaching hospital by using a team of dedicated phlebotomists. Calculations made with our data and those published by others suggest that cost savings from reducing false-positive blood cultures are greater than the cost of the blood culture team.

  2. Blood cultures in emergency medical admissions: a key patient cohort.

    PubMed

    Chotirmall, Sanjay H; Callaly, Elizabeth; Lyons, Judith; O'Connell, Brian; Kelleher, Mary; Byrne, Declan; O'Riordan, Deirdre; Silke, Bernard

    2016-02-01

    Blood cultures are performed in the emergency room when sepsis is suspected, and a cohort of patients is thereby identified. The present study investigated the outcomes (mortality and length of hospital stay) in this group following an emergency medical admission. Prospective assessment of all emergency medical admissions presenting to the emergency department at St James's Hospital, Dublin, over an 11-year period (2002-2012) was carried out. Outcomes including 30-day in-hospital mortality and length of stay were explored in the context of an admission blood culture. Generalized estimating equations, logistic or zero-truncated Poisson multivariate models were used, with adjustment for confounding variables including illness severity, comorbidity, and chronic disabling disease, to assess the effect of an urgent blood culture on mortality and length of stay. A total of 60 864 episodes were recorded in 35 168 patients admitted over the time period assessed. Patients more likely to undergo blood cultures in the emergency department were male, younger, and had more comorbidity. Univariate and multivariate analyses showed that those who had a blood culture, irrespective of result, had increased mortality and a longer in-hospital stay. This was highest for those with a positive culture, irrespective of the organism isolated. A clinical decision to request a blood culture identified a subset of emergency admissions with markedly worse outcomes. This patient cohort warrants close monitoring in the emergency setting.

  3. Potential Impact of Rapid Blood Culture Testing for Gram-Positive Bacteremia in Japan with the Verigene Gram-Positive Blood Culture Test

    PubMed Central

    Matsuda, Mari; Iguchi, Shigekazu; Mizutani, Tomonori; Hiramatsu, Keiichi; Tega-Ishii, Michiru; Sansaka, Kaori; Negishi, Kenta; Shimada, Kimie; Umemura, Jun; Notake, Shigeyuki; Yanagisawa, Hideji; Yabusaki, Reiko; Araoka, Hideki; Yoneyama, Akiko

    2017-01-01

    Background. Early detection of Gram-positive bacteremia and timely appropriate antimicrobial therapy are required for decreasing patient mortality. The purpose of our study was to evaluate the performance of the Verigene Gram-positive blood culture assay (BC-GP) in two special healthcare settings and determine the potential impact of rapid blood culture testing for Gram-positive bacteremia within the Japanese healthcare delivery system. Furthermore, the study included simulated blood cultures, which included a library of well-characterized methicillin-resistant Staphylococcus aureus (MRSA) and vancomycin-resistant enterococci (VRE) isolates reflecting different geographical regions in Japan. Methods. A total 347 BC-GP assays were performed on clinical and simulated blood cultures. BC-GP results were compared to results obtained by reference methods for genus/species identification and detection of resistance genes using molecular and MALDI-TOF MS methodologies. Results. For identification and detection of resistance genes at two clinical sites and simulated blood cultures, overall concordance of BC-GP with reference methods was 327/347 (94%). The time for identification and antimicrobial resistance detection by BC-GP was significantly shorter compared to routine testing especially at the cardiology hospital, which does not offer clinical microbiology services on weekends and holidays. Conclusion. BC-GP generated accurate identification and detection of resistance markers compared with routine laboratory methods for Gram-positive organisms in specialized clinical settings providing more rapid results than current routine testing. PMID:28316631

  4. Effect of postmortem sampling technique on the clinical significance of autopsy blood cultures.

    PubMed

    Hove, M; Pencil, S D

    1998-02-01

    Our objective was to investigate the value of postmortem autopsy blood cultures performed with an iodine-subclavian technique relative to the classical method of atrial heat searing and antemortem blood cultures. The study consisted of a prospective autopsy series with each case serving as its own control relative to subsequent testing, and a retrospective survey of patients coming to autopsy who had both autopsy blood cultures and premortem blood cultures. A busy academic autopsy service (600 cases per year) at University of Texas Medical Branch Hospitals, Galveston, Texas, served as the setting for this work. The incidence of non-clinically relevant (false-positive) culture results were compared using different methods for collecting blood samples in a prospective series of 38 adult autopsy specimens. One hundred eleven adult autopsy specimens in which both postmortem and antemortem blood cultures were obtained were studied retrospectively. For both studies, positive culture results were scored as either clinically relevant or false positives based on analysis of the autopsy findings and the clinical summary. The rate of false-positive culture results obtained by an iodine-subclavian technique from blood drawn soon after death were statistically significantly lower (13%) than using the classical method of obtaining blood through the atrium after heat searing at the time of the autopsy (34%) in the same set of autopsy subjects. When autopsy results were compared with subjects' antemortem blood culture results, there was no significant difference in the rate of non-clinically relevant culture results in a paired retrospective series of antemortem blood cultures and postmortem blood cultures using the iodine-subclavian postmortem method (11.7% v 13.5%). The results indicate that autopsy blood cultures obtained using the iodine-subclavian technique have reliability equivalent to that of antemortem blood cultures.

  5. Highly Sensitive Bacteriophage-Based Detection of Brucella abortus in Mixed Culture and Spiked Blood

    PubMed Central

    Sergueev, Kirill V.; Filippov, Andrey A.; Nikolich, Mikeljon P.

    2017-01-01

    For decades, bacteriophages (phages) have been used for Brucella species identification in the diagnosis and epidemiology of brucellosis. Traditional Brucella phage typing is a multi-day procedure including the isolation of a pure culture, a step that can take up to three weeks. In this study, we focused on the use of brucellaphages for sensitive detection of the pathogen in clinical and other complex samples, and developed an indirect method of Brucella detection using real-time quantitative PCR monitoring of brucellaphage DNA amplification via replication on live Brucella cells. This assay allowed the detection of single bacteria (down to 1 colony-forming unit per milliliter) within 72 h without DNA extraction and purification steps. The technique was equally efficient with Brucella abortus pure culture and with mixed cultures of B. abortus and α-proteobacterial near neighbors that can be misidentified as Brucella spp., Ochrobactrum anthropi and Afipia felis. The addition of a simple short sample preparation step enabled the indirect phage-based detection of B. abortus in spiked blood, with the same high sensitivity. This indirect phage-based detection assay enables the rapid and sensitive detection of live B. abortus in mixed cultures and in blood samples, and can potentially be applied for detection in other clinical samples and other complex sample types. PMID:28604602

  6. Deficits in knowledge, attitude, and practice towards blood culture sampling: results of a nationwide mixed-methods study among inpatient care physicians in Germany.

    PubMed

    Raupach-Rosin, Heike; Duddeck, Arne; Gehrlich, Maike; Helmke, Charlotte; Huebner, Johannes; Pletz, Mathias W; Mikolajczyk, Rafael; Karch, André

    2017-08-01

    Blood culture (BC) sampling rates in Germany are considerably lower than recommended. Aim of our study was to assess knowledge, attitudes, and practice of physicians in Germany regarding BC diagnostics. We conducted a cross-sectional mixed-methods study among physicians working in inpatient care in Germany. Based on the results of qualitative focus groups, a questionnaire-based quantitative study was conducted in 2015-2016. In total, 706 medical doctors and final-year medical students from 11 out of 16 federal states in Germany participated. BC sampling was considered an important diagnostic tool by 95% of the participants. However, only 23% of them would collect BCs in three scenarios for which BC ordering is recommended by present guidelines in Germany; almost one out of ten physicians would not have taken blood cultures in any of the three scenarios. The majority of participants (74%) reported not to adhere to the guideline recommendation that blood culture sampling should include at least two blood culture sets from two different injection sites. High routine in blood culture sampling, perceived importance of blood culture diagnostics, the availability of an in-house microbiological lab, and the department the physician worked in were identified as predictors for good blood culture practice. Our study suggests that there are substantial deficits in BC ordering and the application of guidelines for good BC practice in Germany. Based on these findings, multimodal interventions appear necessary for improving BC diagnostics.

  7. Comparison between MALDI-TOF MS and FilmArray Blood Culture Identification panel for rapid identification of yeast from positive blood culture.

    PubMed

    Paolucci, M; Foschi, C; Tamburini, M V; Ambretti, S; Lazzarotto, T; Landini, M P

    2014-09-01

    In this study we evaluated MALDI-TOF MS and FilmArray methods for the rapid identification of yeast from positive blood cultures. FilmArray correctly identified 20/22 of yeast species, while MALDI-TOF MS identified 9/22. FilmArray is a reliable and rapid identification system for the direct identification of yeasts from positive blood cultures. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Blood culture-negative endocarditis

    PubMed Central

    Fournier, Pierre-Edouard; Gouriet, Frédérique; Casalta, Jean-Paul; Lepidi, Hubert; Chaudet, Hervé; Thuny, Franck; Collart, Frédéric; Habib, Gilbert; Raoult, Didier

    2017-01-01

    Abstract Blood culture-negative endocarditis (BCNE) may represent up to 70% of all endocarditis cases, depending on series. From 2001 to 2009, we implemented in our laboratory a multimodal diagnostic strategy for BCNE that included systematized testing of blood, and when available, valvular biopsy specimens using serological, broad range molecular, and histopathological assays. A causative microorganism was identified in 62.7% of patients. In this study from January 2010 to December 2015, in an effort to increase the number of identified causative microorganisms, we prospectively added to our diagnostic protocol specific real-time (RT) polymerase chain reaction (PCR) assays targeting various endocarditis agents, and applied them to all patients with BCNE admitted to the 4 public hospitals in Marseille, France. A total of 283 patients with BCNE were included in the study. Of these, 177 were classified as having definite endocarditis. Using our new multimodal diagnostic strategy, we identified an etiology in 138 patients (78.0% of cases). Of these, 3 were not infective (2.2%) and 1 was diagnosed as having Mycobacterium bovis BCG endocarditis. By adding specific PCR assays from blood and valvular biopsies, which exhibited a significantly greater sensitivity (P < 10−2) than other methods, causative agents, mostly enterococci, streptococci, and zoonotic microorganisms, were identified in an additional 27 patients (14 from valves only, 11 from blood only, and 2 from both). Finally, in another 107 patients, a pathogen was detected using serology in 37, valve culture in 8, broad spectrum PCR from valvular biopsies and blood in 19 and 2, respectively, immunohistochemistry from valves in 3, and a combination of several assays in 38. By adding specific RT-PCR assays to our systematic PCR testing of patients with BCNE, we increased the diagnostic efficiency by 24.3%, mostly by detecting enterococci and streptococci that had not been detected by other diagnostic methods

  9. Diagnostic performance of blood culture bottles for vitreous culture compared to conventional microbiological cultures in patients with suspected endophthalmitis.

    PubMed

    Kehrmann, Jan; Chapot, Valerie; Buer, Jan; Rating, Philipp; Bornfeld, Norbert; Steinmann, Joerg

    2018-05-01

    The purpose of this investigation was to evaluate the performance of blood culture bottles in comparison to conventional microbiological culture techniques in detecting causative microorganisms of endophthalmitis and to determine their anti-infective susceptibility profiles. All consecutive cases with clinically suspected endophthalmitis in a university-based ophthalmology department between January 2009 and December 2016 were analysed in this retrospective comparative case series. Samples from 247 patients with suspected endophthalmitis underwent microbiological diagnostic work-up. All three culture methods were performed from 140 vitreous specimens. Vitreous fluid specimens were inoculated in blood culture bottles, aerobic and anaerobic broth solutions, and on solid media. Anti-infective susceptibility profiles were evaluated by semi-automated methods and/or gradient diffusion methods. Microorganisms were grown in 82 of 140 specimens for which all methods were performed (59%). Microorganisms were more frequently grown from blood culture bottles (55%) compared to broth solution (45%, p = 0.007) and solid media (33%, p < 0.0001). Considerable differences in the performance among culture media were detected for fungal pathogens. All grown fungi were detected by blood culture bottles (11 of 11, 100%). Broth solution recovered 64% and solid media 46% of grown fungi. No Gram-positive bacterium was resistant to vancomycin and all Gram-negative pathogens except for one isolate were susceptible to third-generation cephalosporins. In suspected endophthalmitis patients, blood culture bottles have a higher overall pathogen detection rate from vitreous fluid compared to conventional microbiological media, especially for fungi. The initial intravitreal antibiotic therapy with vancomycin plus third-generation cephalosporins appears to be an appropriate treatment approach for bacterial endophthalmitis.

  10. Reduction in Blood Culture Contamination Through Use of Initial Specimen Diversion Device.

    PubMed

    Rupp, Mark E; Cavalieri, R Jennifer; Marolf, Cole; Lyden, Elizabeth

    2017-07-15

    Blood culture contamination is a clinically significant problem that results in patient harm and excess cost. In a prospective, controlled trial at an academic center Emergency Department, a device that diverts and sequesters the initial 1.5-2 mL portion of blood (which presumably carries contaminating skin cells and microbes) was tested against standard phlebotomy procedures in patients requiring blood cultures due to clinical suspicion of serious infection. In sum, 971 subjects granted informed consent and were enrolled resulting in 904 nonduplicative subjects with 1808 blood cultures. Blood culture contamination was significantly reduced through use of the initial specimen diversion device™ (ISDD) compared to standard procedure: (2/904 [0.22%] ISDD vs 16/904 [1.78%] standard practice, P = .001). Sensitivity was not compromised: true bacteremia was noted in 65/904 (7.2%) ISDD vs 69/904 (7.6%) standard procedure, P = .41. No needlestick injuries or potential bloodborne pathogen exposures were reported. The monthly rate of blood culture contamination for all nurse-drawn and phlebotomist-drawn blood cultures was modeled using Poisson regression to compare the 12-month intervention period to the 6 month before and after periods. Phlebotomists (used the ISDD) experienced a significant decrease in blood culture contamination while the nurses (did not use the ISDD) did not. In sum, 73% of phlebotomists completed a post-study anonymous survey and widespread user satisfaction was noted. Use of the ISDD was associated with a significant decrease in blood culture contamination in patients undergoing blood cultures in an Emergency Department setting. NCT02102087. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.

  11. Reduction in Blood Culture Contamination Through Use of Initial Specimen Diversion Device

    PubMed Central

    Cavalieri, R. Jennifer; Marolf, Cole; Lyden, Elizabeth

    2017-01-01

    Abstract Background. Blood culture contamination is a clinically significant problem that results in patient harm and excess cost. Methods. In a prospective, controlled trial at an academic center Emergency Department, a device that diverts and sequesters the initial 1.5–2 mL portion of blood (which presumably carries contaminating skin cells and microbes) was tested against standard phlebotomy procedures in patients requiring blood cultures due to clinical suspicion of serious infection. Results. In sum, 971 subjects granted informed consent and were enrolled resulting in 904 nonduplicative subjects with 1808 blood cultures. Blood culture contamination was significantly reduced through use of the initial specimen diversion device™ (ISDD) compared to standard procedure: (2/904 [0.22%] ISDD vs 16/904 [1.78%] standard practice, P = .001). Sensitivity was not compromised: true bacteremia was noted in 65/904 (7.2%) ISDD vs 69/904 (7.6%) standard procedure, P = .41. No needlestick injuries or potential bloodborne pathogen exposures were reported. The monthly rate of blood culture contamination for all nurse-drawn and phlebotomist-drawn blood cultures was modeled using Poisson regression to compare the 12-month intervention period to the 6 month before and after periods. Phlebotomists (used the ISDD) experienced a significant decrease in blood culture contamination while the nurses (did not use the ISDD) did not. In sum, 73% of phlebotomists completed a post-study anonymous survey and widespread user satisfaction was noted. Conclusions. Use of the ISDD was associated with a significant decrease in blood culture contamination in patients undergoing blood cultures in an Emergency Department setting. Clinical Trials Registration. NCT02102087. PMID:28379370

  12. An affordable method to obtain cultured endothelial cells from peripheral blood

    PubMed Central

    Bueno-Betí, Carlos; Novella, Susana; Lázaro-Franco, Macarena; Pérez-Cremades, Daniel; Heras, Magda; Sanchís, Juan; Hermenegildo, Carlos

    2013-01-01

    The culture of endothelial progenitor cells (EPC) provides an excellent tool to research on EPC biology and vascular regeneration and vasculogenesis. The use of different protocols to obtain EPC cultures makes it difficult to obtain comparable results in different groups. This work offers a systematic comparison of the main variables of most commonly used protocols for EPC isolation, culture and functional evaluation. Peripheral blood samples from healthy individuals were recovered and mononuclear cells were cultured. Different recovery and culture conditions were tested: blood volume, blood anticoagulant, coating matrix and percentage of foetal bovine serum (FBS) in culture media. The success of culture procedure, first colonies of endothelial cells appearance time, correlation with number of circulating EPC (cEPC) and functional comparison with human umbilical vein endothelial cells (HUVEC) were studied. The use of heparin, a minimum blood volume of 30 ml, fibronectin as a coating matrix and endothelial growing media-2 supplemented with 20% FBS increased the success of obtaining EPC cultures up to 80% of the processed samples while reducing EPC colony appearance mean time to a minimum of 13 days. Blood samples exhibiting higher cEPC numbers resulted in reduced EPC colony appearance mean time. Cells isolated by using this combination were endothelial cell-like EPCs morphological and phenotypically. Functionally, cultured EPC showed decreased growing and vasculogenic capacity when compared to HUVEC. Thus, above-mentioned conditions allow the isolation and culture of EPC with smaller blood volumes and shorter times than currently used protocols. PMID:24118735

  13. Assessment of anaerobic blood cultures in pediatric oncology patients.

    PubMed

    Monsonís Cabedo, Manuel; Rives Solá, Susana; Noguera-Julian, Antoni; Urrea Ayala, Mireia; Cruz Martinez, Ofelia; Gené Giralt, Amadeu

    2017-01-01

    The routine use of a single aerobic bottle for blood culture in pediatric patients has become commonplace, as anaerobic bacteria are not frequently involved in clinically significant infections. The aim of this study was to assess the usefulness of routinely performing anaerobic blood cultures in pediatric oncology patients. Prospective study was conducted on pediatric (<18 years) patients affected with febrile syndrome after receiving chemotherapy for hematological or solid malignancies. Samples were inoculated into pediatric aerobic and standard anaerobic bottles (BacT/Alert automatic system). Strains were considered clinically significant, or deemed as contaminants, depending on isolation circumstances and clinical criteria. A total of 876 blood cultures from 228 patients were processed during the 21-month study period (January 2014 to September 2015). Baseline diagnosis included 143 solid tumors and 67/18 cases of leukemia/lymphoma. Bacterial growth was detected in 90 (10.2%) blood cultures for 95 different isolates, of which 62 (7.1%)/63 isolates were considered clinically significant. Among the latter, 38 (60.3%) microorganisms grew in both aerobic and anaerobic bottles, 18 (28.6%) only in aerobic bottles, and 7 (11.1%) only in anaerobic bottles. Gram-negative bacilli (33; 52.4%), mainly from the Enterobacteriaceae family, were the most frequently isolated microorganisms. Overall, only 3 out of 90 isolates (3.3%) were strict anaerobes (Propionibacterium acnes), and all of them were deemed contaminants. Strict anaerobes did not cause significant infections in febrile pediatric oncology patients, and anaerobic blood culture bottles offered no additional advantages over aerobic media. Our results suggest that routine blood cultures should be solely processed in aerobic media in this group of patients. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  14. Does this adult patient with suspected bacteremia require blood cultures?

    PubMed

    Coburn, Bryan; Morris, Andrew M; Tomlinson, George; Detsky, Allan S

    2012-08-01

    Clinicians order blood cultures liberally among patients in whom bacteremia is suspected, though a small proportion of blood cultures yield true-positive results. Ordering blood cultures inappropriately may be both wasteful and harmful. To review the accuracy of easily obtained clinical and laboratory findings to inform the decision to obtain blood cultures in suspected bacteremia. A MEDLINE and EMBASE search (inception to April 2012) yielded 35 studies that met inclusion criteria for evaluating the accuracy of clinical variables for bacteremia in adult immunocompetent patients, representing 4566 bacteremia and 25,946 negative blood culture episodes. Data were extracted to determine the prevalence and likelihood ratios (LRs) of findings for bacteremia. The pretest probability of bacteremia varies depending on the clinical context, from low (eg, cellulitis: 2%) to high (eg, septic shock: 69%). Elevated temperatures alone do not accurately predict bacteremia (for ≥38°C [>100.3°F], LR, 1.9 [95% CI, 1.4-2.4]; for ≥38.5°C [>101.2°F], LR, 1.4 [95% CI, 1.1-2.0]), nor does isolated leukocytosis (LR, <1.7). The severity of chills graded on an ordinal scale (shaking chills, LR, 4.7; 95% CI, 3.0-7.2) may be more useful. Both the systemic inflammatory response syndrome (SIRS) and a multivariable decision rule with major and minor criteria are sensitive (but not specific) predictors of bacteremia (SIRS, negative LR, 0.09 [95% CI, 0.03-0.26]; decision rule, negative LR, 0.08 [95% CI, 0.04-0.17]). Blood cultures should not be ordered for adult patients with isolated fever or leukocytosis without considering the pretest probability. SIRS and the decision rule may be helpful in identifying patients who do not need blood cultures. These conclusions do not apply to immunocompromised patients or when endocarditis is suspected.

  15. Quantitative and multiplexed detection for blood typing based on quantum dot-magnetic bead assay.

    PubMed

    Xu, Ting; Zhang, Qiang; Fan, Ya-Han; Li, Ru-Qing; Lu, Hua; Zhao, Shu-Ming; Jiang, Tian-Lun

    2017-01-01

    Accurate and reliable blood grouping is essential for safe blood transfusion. However, conventional methods are qualitative and use only single-antigen detection. We overcame these limitations by developing a simple, quantitative, and multiplexed detection method for blood grouping using quantum dots (QDs) and magnetic beads. In the QD fluorescence assay (QFA), blood group A and B antigens were quantified using QD labeling and magnetic beads, and the blood groups were identified according to the R value (the value was calculated with the fluorescence intensity from dual QD labeling) of A and B antigens. The optimized performance of QFA was established by blood typing 791 clinical samples. Quantitative and multiplexed detection for blood group antigens can be completed within 35 min with more than 10 5 red blood cells. When conditions are optimized, the assay performance is satisfactory for weak samples. The coefficients of variation between and within days were less than 10% and the reproducibility was good. The ABO blood groups of 791 clinical samples were identified by QFA, and the accuracy obtained was 100% compared with the tube test. Receiver-operating characteristic curves revealed that the QFA has high sensitivity and specificity toward clinical samples, and the cutoff points of the R value of A and B antigens were 1.483 and 1.576, respectively. In this study, we reported a novel quantitative and multiplexed method for the identification of ABO blood groups and presented an effective alternative for quantitative blood typing. This method can be used as an effective tool to improve blood typing and further guarantee clinical transfusion safety.

  16. Dynamic and quantitative assessment of blood coagulation using optical coherence elastography

    PubMed Central

    Xu, Xiangqun; Zhu, Jiang; Chen, Zhongping

    2016-01-01

    Reliable clot diagnostic systems are needed for directing treatment in a broad spectrum of cardiovascular diseases and coagulopathy. Here, we report on non-contact measurement of elastic modulus for dynamic and quantitative assessment of whole blood coagulation using acoustic radiation force orthogonal excitation optical coherence elastography (ARFOE-OCE). In this system, acoustic radiation force (ARF) is produced by a remote ultrasonic transducer, and a shear wave induced by ARF excitation is detected by the optical coherence tomography (OCT) system. During porcine whole blood coagulation, changes in the elastic property of the clots increase the shear modulus of the sample, altering the propagating velocity of the shear wave. Consequently, dynamic blood coagulation status can be measured quantitatively by relating the velocity of the shear wave with clinically relevant coagulation metrics, including reaction time, clot formation kinetics and maximum shear modulus. The results show that the ARFOE-OCE is sensitive to the clot formation kinetics and can differentiate the elastic properties of the recalcified porcine whole blood, blood added with kaolin as an activator, and blood spiked with fibrinogen. PMID:27090437

  17. Dynamic and quantitative assessment of blood coagulation using optical coherence elastography

    NASA Astrophysics Data System (ADS)

    Xu, Xiangqun; Zhu, Jiang; Chen, Zhongping

    2016-04-01

    Reliable clot diagnostic systems are needed for directing treatment in a broad spectrum of cardiovascular diseases and coagulopathy. Here, we report on non-contact measurement of elastic modulus for dynamic and quantitative assessment of whole blood coagulation using acoustic radiation force orthogonal excitation optical coherence elastography (ARFOE-OCE). In this system, acoustic radiation force (ARF) is produced by a remote ultrasonic transducer, and a shear wave induced by ARF excitation is detected by the optical coherence tomography (OCT) system. During porcine whole blood coagulation, changes in the elastic property of the clots increase the shear modulus of the sample, altering the propagating velocity of the shear wave. Consequently, dynamic blood coagulation status can be measured quantitatively by relating the velocity of the shear wave with clinically relevant coagulation metrics, including reaction time, clot formation kinetics and maximum shear modulus. The results show that the ARFOE-OCE is sensitive to the clot formation kinetics and can differentiate the elastic properties of the recalcified porcine whole blood, blood added with kaolin as an activator, and blood spiked with fibrinogen.

  18. Utility of blood cultures in children admitted to hospital with community-acquired pneumonia.

    PubMed

    Davis, Tessa R; Evans, Hannah R; Murtas, Jennifer; Weisman, Aimee; Francis, J Lynn; Khan, Ahmed

    2017-03-01

    The aim of the study was to assess the utility of blood cultures in children admitted to hospital with community-acquired pneumonia. The primary outcome was the number of positive blood culture results, and secondary outcomes included the effect of positive blood culture results on management, and the identification of other clinical/biochemical variables that could predict blood culture results or the course of illness. A retrospective data analysis was carried out on all children admitted to Gosford Hospital during the 2-year period from July 2013 to June 2015. Included were patients under 16 years old who had a diagnosis-related group code of pneumonia. A review of blood culture results, chest X-ray, serology, C-reactive protein and white cell count and clinical outcomes were analysed. There were 215 paediatric admissions with a diagnosis of pneumonia during the 2-year study period. A blood culture was collected in 82.3% (177/215). Although seven had a positive blood culture, only two of these were finally reported as true positives and both were Streptococcus pneumoniae. Both patients were treated with a cephalosporin and demonstrated clinical improvement. No changes were made to their treatment based on the blood culture results. Blood cultures have a low yield and do not appear to be helpful when collected in all patients admitted to hospital with community-acquired pneumonia. © 2016 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  19. What are the critical steps in processing blood cultures? A prospective audit evaluating current practice of reporting blood cultures in a centralised laboratory serving secondary care hospitals.

    PubMed

    Meda, Manjula; Clayton, James; Varghese, Reela; Rangaiah, Jayakeerthi; Grundy, Clive; Dashti, Farnaz; Garner, David; Groves, Katherine; Fitzmaurice, Karen; Hutley, E

    2017-04-01

    To assess current procedures of processing positive blood cultures against national standards with an aim to evaluate its clinical impact and to determine the utility of currently available rapid identification and susceptibility tests in processing of blood cultures. Blood cultures from three secondary care hospitals, processed at a centralised laboratory, were prospectively audited. Data regarding processing times, communication with prescribers, changes to patient management and mortality within 30 days of a significant blood culture were collected in a preplanned pro forma for a 4-week period. Of 2206 blood cultures, 211 positive blood cultures flagged positive. Sixty-nine (3.1%) of all cultures were considered to be contaminated. Fifty per cent of blood cultures that flagged positive had a Gram stain reported within 2 hours. Two (0.99%) patients with a significant bacteraemia had escalation of antimicrobial treatment at the point of reporting the Gram stain that was subsequently deemed necessary once sensitivity results were known. Most common intervention was de-escalation of therapy for Gram-positive organisms at the point of availability of pathogen identification (25.6% in Gram positive vs 10% in Gram negative; p=0.012). For Gram-negative organisms, the most common intervention was de-escalation of therapy at the point of availability of sensitivity results (43% in Gram negatives vs 17.9% in Gram positive; p=0.0097). Overall mortality within 30 days of a positive blood culture was 10.9% (23/211). Antibiotic resistance may have contributed to mortality in four of these patients (three Gram negative and one Gram positive). Gram stain result had the least impact on antibiotic treatment interventions (escalation or de-escalation). Tests that improve identification time for Gram-positive pathogens and sensitivity time for Gram-negative pathogens had the greatest impact in making significant changes to antimicrobial treatment. Published by the BMJ

  20. Routine blood cultures in the management of pyelonephritis in pregnancy for improving outcomes.

    PubMed

    Gomi, Harumi; Goto, Yoshihito; Laopaiboon, Malinee; Usui, Rie; Mori, Rintaro

    2015-02-13

    Pyelonephritis is a type of urinary tract infection (UTI) that affects the upper urinary tract and kidneys, and is one of the most common conditions for hospitalisation among pregnant women, aside from delivery. Samples of urine and blood are obtained and used for cultures as part of the diagnosis and management of the condition. Acute pyelonephritis requires hospitalisation with intravenous administration of antimicrobial agents. Several studies have questioned the necessity of obtaining blood cultures in addition to urine cultures, citing cost and questioning whether blood testing is superfluous. Pregnant women with bacteraemia require a change in the initial empirical treatment based on the blood culture. However, these cases are not common, and represent approximately 15% to 20% of cases. It is unclear whether blood cultures are essential for the effective management of the condition. To assess the effectiveness of routine blood cultures to improve health outcomes in the management of pyelonephritis in pregnant women. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register without language or date restrictions (31 December 2014). Randomised controlled trials and quasi-randomised trials comparing outcomes among pregnant women with pyelonephritis who received initial management with or without blood cultures. Cluster-randomised trials were eligible for inclusion in this review but none were identified. Clinical trials using a cross-over design were not eligible for inclusion. Two review authors independently assessed one trial report for inclusion. We identified one trial report but this was excluded. No clinical trials met the inclusion criteria for this review. There are no large-scale randomised controlled trials to assess outcomes in the management of pyelonephritis in pregnancy with or without blood cultures. Randomised controlled trials are needed to evaluate the effectiveness of managing pyelonephritis in pregnant women with or without

  1. Cultured blood versus donated blood: long-run perspectives of the economy of blood.

    PubMed

    Mercier Ythier, Jean

    2015-01-01

    Recent advances of fundamental research on the in vitro generation of red blood cells (RBCs) from hematopoietic stem cells in the laboratory open new possibilities of the utilization of cultured RBCs in transfusion medicine. We study the economic challenge of the setup and development of the mass industrial production of RBCs in mature transfusion organizations. We argue that: (i) RBC manufacturing could be set up and developed in the short-medium run for the treatment of the small proportion of transfused patients who have a rare blood type or are alloimmunized against blood antigens; (ii) manufactured RBCs could substitute for donated RBCs in the long run if the physical productivity of RBC engineering technology approaches that of bone marrow.

  2. Factors affecting Brucella spp. blood cultures positivity in children.

    PubMed

    Apa, Hurşit; Devrim, Ilker; Memur, Seyma; Günay, Ilker; Gülfidan, Gamze; Celegen, Mehmet; Bayram, Nuri; Karaarslan, Utku; Bağ, Ozlem; Işgüder, Rana; Oztürk, Aysel; Inan, Seyhan; Unal, Nurrettin

    2013-03-01

    Brucella infections have a wide spectrum of symptoms especially in children, making the diagnosis a complicated process. The gold standard for the final diagnosis for brucellosis is to identify the Brucella spp. isolated from blood or bone marrow cultures. The main purpose of this work was to evaluate the factors affecting the isolation of Brucella spp. from blood cultures. In our study, the ratio of fever, presence of hepatomegaly, and splenomegaly were found to be higher in the bacteremic group. In addition, C-reactive protein levels and liver function enzymes were found to be higher in the bacteremic group. In our opinion, while evaluating the febrile child with suspected Brucella infection, we highly recommend sampling blood cultures regardless of the history of previous antimicrobial therapy and duration of the symptoms.

  3. Sensitive and quantitative measurement of gene expression directly from a small amount of whole blood.

    PubMed

    Zheng, Zhi; Luo, Yuling; McMaster, Gary K

    2006-07-01

    Accurate and precise quantification of mRNA in whole blood is made difficult by gene expression changes during blood processing, and by variations and biases introduced by sample preparations. We sought to develop a quantitative whole-blood mRNA assay that eliminates blood purification, RNA isolation, reverse transcription, and target amplification while providing high-quality data in an easy assay format. We performed single- and multiplex gene expression analysis with multiple hybridization probes to capture mRNA directly from blood lysate and used branched DNA to amplify the signal. The 96-well plate singleplex assay uses chemiluminescence detection, and the multiplex assay combines Luminex-encoded beads with fluorescent detection. The single- and multiplex assays could quantitatively measure as few as 6000 and 24,000 mRNA target molecules (0.01 and 0.04 amoles), respectively, in up to 25 microL of whole blood. Both formats had CVs < 10% and dynamic ranges of 3-4 logs. Assay sensitivities allowed quantitative measurement of gene expression in the minority of cells in whole blood. The signals from whole-blood lysate correlated well with signals from purified RNA of the same sample, and absolute mRNA quantification results from the assay were similar to those obtained by quantitative reverse transcription-PCR. Both single- and multiplex assay formats were compatible with common anticoagulants and PAXgene-treated samples; however, PAXgene preparations induced expression of known antiapoptotic genes in whole blood. Both the singleplex and the multiplex branched DNA assays can quantitatively measure mRNA expression directly from small volumes of whole blood. The assay offers an alternative to current technologies that depend on RNA isolation and is amenable to high-throughput gene expression analysis of whole blood.

  4. Comparative evaluation of paired blood culture (aerobic/aerobic) and single blood culture, along with clinical importance in catheter versus peripheral line at a tertiary care hospital.

    PubMed

    Tarai, B; Das, P; Kumar, D; Budhiraja, S

    2012-01-01

    Paired blood culture (PBC) is uncommon practice in hospitals in India, leading to delayed and inadequate diagnosis. Also contamination remains a critical determinant in hampering the definitive diagnosis. To establish the need of PBC over single blood culture (SBC) along with the degree of contamination, this comparative retrospective study was initiated. We processed 2553 PBC and 4350 SBC in BacT/ALERT 3D (bioMerieux) between October 2010 and June 2011. The positive cultures were identified in VITEK 2 Compact (bioMerieux). True positivity and contaminants were also analyzed in 486 samples received from catheter and peripheral line. Out of 2553 PBC samples, positivity was seen in 350 (13.70%). In 4350 SBC samples, positivity was seen in 200 samples (4.59%). In PBC true pathogens were 267 (10.45%) and contaminants were 83 (3.25%), whereas in SBC 153 (3.51%) were true positives and contaminants were 47 (1.08%). Most of the blood cultures (99.27 %) grew within 72 h and 95.8% were isolated within 48 h. In 486 PBCs received from catheter/periphery (one each), catheter positivity was found in 85 (true positives were 48, false positives 37). In peripheral samples true positives were 50 and false positives were 8. Significantly higher positive rates were seen in PBCs compared with SBCs. Automated blood culture and identification methods significantly reduced the time required for processing of samples and also facilitated yield of diverse/rare organisms. Blood culture from catheter line had higher false positives than peripheral blood culture. Thus every positive result from a catheter must be correlated with clinical findings and requires further confirmation.

  5. Quantitative cultures of endotracheal aspirates for the diagnosis of ventilator-associated pneumonia.

    PubMed

    el-Ebiary, M; Torres, A; González, J; de la Bellacasa, J P; García, C; Jiménez de Anta, M T; Ferrer, M; Rodriguez-Roisin, R

    1993-12-01

    Bronchoalveolar lavage (BAL) and protected specimen brushing (PSB) are the most commonly used methods for diagnosing ventilator-associated (VA) pneumonia although they require bronchoscopy. Endotracheal aspiration (EA) is a simple and less costly technique than PSB or BAL. The purpose of our study was to investigate the diagnostic value of EA quantitative cultures and to compare the results obtained using EA with those obtained using PSB and BAL in mechanically ventilated patients with or without pneumonia. We prospectively studied 102 intubated patients divided into three diagnostic categories: Group I (definite pneumonia, n = 26), Group II (uncertain status, n = 48), and Group III (control group, n = 28). All patients received prior antibiotic treatment. EA, PSB, and BAL were obtained sequentially in all patients. When comparing Group I with Group III and using 10(5) cfu/ml as a threshold, we found that EA quantitative cultures represented a relatively sensitive (70%) and relatively specific (72%) method to diagnose VA pneumonia. The specificity of BAL and PSB (87% and 93%, respectively) was better than that of EA. The negative predictive value of EA cultures was higher (72%) when compared with that obtained using PSB (34%) (p < 0.05). EA quantitative cultures correlated with PSB and BAL quantitative cultures in patients with definite pneumonia. Although EA quantitative cultures are less specific than PSB and BAL for diagnosing VA pneumonia, our results suggest that the former approach may be used to treat these patients when bronchoscopic procedures are not available.

  6. Proposing an Empirically Justified Reference Threshold for Blood Culture Sampling Rates in Intensive Care Units

    PubMed Central

    Castell, Stefanie; Schwab, Frank; Geffers, Christine; Bongartz, Hannah; Brunkhorst, Frank M.; Gastmeier, Petra; Mikolajczyk, Rafael T.

    2014-01-01

    Early and appropriate blood culture sampling is recommended as a standard of care for patients with suspected bloodstream infections (BSI) but is rarely taken into account when quality indicators for BSI are evaluated. To date, sampling of about 100 to 200 blood culture sets per 1,000 patient-days is recommended as the target range for blood culture rates. However, the empirical basis of this recommendation is not clear. The aim of the current study was to analyze the association between blood culture rates and observed BSI rates and to derive a reference threshold for blood culture rates in intensive care units (ICUs). This study is based on data from 223 ICUs taking part in the German hospital infection surveillance system. We applied locally weighted regression and segmented Poisson regression to assess the association between blood culture rates and BSI rates. Below 80 to 90 blood culture sets per 1,000 patient-days, observed BSI rates increased with increasing blood culture rates, while there was no further increase above this threshold. Segmented Poisson regression located the threshold at 87 (95% confidence interval, 54 to 120) blood culture sets per 1,000 patient-days. Only one-third of the investigated ICUs displayed blood culture rates above this threshold. We provided empirical justification for a blood culture target threshold in ICUs. In the majority of the studied ICUs, blood culture sampling rates were below this threshold. This suggests that a substantial fraction of BSI cases might remain undetected; reporting observed BSI rates as a quality indicator without sufficiently high blood culture rates might be misleading. PMID:25520442

  7. Effectiveness of introducing blood culture collection packs to reduce contamination rates.

    PubMed

    Bamber, A I; Cunniffe, J G; Nayar, D; Ganguly, R; Falconer, E

    2009-01-01

    Contaminated blood cultures result in a significant waste of healthcare resources and can lead to inappropriate antibiotic therapy. Practitioners have taken measures to reduce contamination rates. These include thorough skin disinfection, effective hand decontamination, introduction of a standardised approach to collection, and the introduction of blood culture collection packs (BCCP). This study aims to assess the impact of introducing BCCP and staff training on the rate of contamination. The study demonstrated that contamination rates are greatest in high patient throughput units where practitioners are under most pressure. The introduction of blood culture packs and staff training has reduced contamination rate significantly from 43% to 25% of the total number of positives, equating to an overall reduction of 42%. Thus, there is a demonstrable benefit in the purchase of commercially produced blood culture packs and the investment in staff training.

  8. Comparison of the clinical and microbiological characteristics of Campylobacter and Helicobacter bacteremia: the importance of time to blood culture positivity using the BACTEC blood culture systems.

    PubMed

    Yamamoto, Kei; Hayakawa, Kayoko; Nagashima, Maki; Shimada, Kayo; Kutsuna, Satoshi; Takeshita, Nozomi; Kato, Yasuyuki; Kanagawa, Shuzo; Yamada, Koji; Mezaki, Kazuhisa; Kirikae, Teruo; Ohmagari, Norio

    2017-11-28

    Campylobacter spp. and Helicobacter spp. are rare but important causes of bacteremia in humans. Distinguishing these bacteria is complicated because of their similar phenotypic profiles. We conducted clinical and microbiological investigations of Campylobacter spp. or Helicobacter spp. bacteremia. Patients diagnosed with bacteremia from 2008 to 2014 were included. The clinical and microbiological characteristics of Campylobacter spp. and Helicobacter spp. bacteremia were compared. The BACTEC system was used in blood cultures. A receiver operating characteristic curve was plotted based on the time to blood culture positivity. Sixteen cases of Helicobacter spp. bacteremia (patient age: 61 ± 18 years) and 14 cases of Campylobacter spp. bacteremia (patient age: 49 ± 21 years) were identified. Median time to blood culture positivity was longer for the Helicobacter spp. cases than the Campylobacter spp. cases (91.4 h vs 55.3 h, p < 0.01). A time to blood culture positivity > 75 h predicted Helicobacter spp. bacteremia with a sensitivity of 0.88 and a specificity of 0.93 (area under the receiver operating characteristic curve of 0.90). In conclusion, a time to blood culture positivity was useful in distinguishing Helicobacter spp. bacteremia from Campylobacter spp. bacteremia.

  9. Quantitative analysis of culture using millions of digitized books

    PubMed Central

    Michel, Jean-Baptiste; Shen, Yuan Kui; Aiden, Aviva P.; Veres, Adrian; Gray, Matthew K.; Pickett, Joseph P.; Hoiberg, Dale; Clancy, Dan; Norvig, Peter; Orwant, Jon; Pinker, Steven; Nowak, Martin A.; Aiden, Erez Lieberman

    2011-01-01

    We constructed a corpus of digitized texts containing about 4% of all books ever printed. Analysis of this corpus enables us to investigate cultural trends quantitatively. We survey the vast terrain of ‘culturomics’, focusing on linguistic and cultural phenomena that were reflected in the English language between 1800 and 2000. We show how this approach can provide insights about fields as diverse as lexicography, the evolution of grammar, collective memory, the adoption of technology, the pursuit of fame, censorship, and historical epidemiology. ‘Culturomics’ extends the boundaries of rigorous quantitative inquiry to a wide array of new phenomena spanning the social sciences and the humanities. PMID:21163965

  10. Quantitative analysis of culture using millions of digitized books.

    PubMed

    Michel, Jean-Baptiste; Shen, Yuan Kui; Aiden, Aviva Presser; Veres, Adrian; Gray, Matthew K; Pickett, Joseph P; Hoiberg, Dale; Clancy, Dan; Norvig, Peter; Orwant, Jon; Pinker, Steven; Nowak, Martin A; Aiden, Erez Lieberman

    2011-01-14

    We constructed a corpus of digitized texts containing about 4% of all books ever printed. Analysis of this corpus enables us to investigate cultural trends quantitatively. We survey the vast terrain of 'culturomics,' focusing on linguistic and cultural phenomena that were reflected in the English language between 1800 and 2000. We show how this approach can provide insights about fields as diverse as lexicography, the evolution of grammar, collective memory, the adoption of technology, the pursuit of fame, censorship, and historical epidemiology. Culturomics extends the boundaries of rigorous quantitative inquiry to a wide array of new phenomena spanning the social sciences and the humanities.

  11. What proportion of Salmonella Typhi cases are detected by blood culture? A systematic literature review.

    PubMed

    Mogasale, Vittal; Ramani, Enusa; Mogasale, Vijayalaxmi V; Park, JuYeon

    2016-05-17

    Blood culture is often used in definitive diagnosis of typhoid fever while, bone marrow culture has a greater sensitivity and considered reference standard. The sensitivity of blood culture measured against bone marrow culture results in measurement bias because both tests are not fully sensitive. Here we propose a combination of the two cultures as a reference to define true positive S. Typhi cases. Based on a systematic literature review, we identified ten papers that had performed blood and bone marrow culture for S. Typhi in same subjects. We estimated the weighted mean of proportion of cases detected by culture measured against true S. Typhi positive cases using a random effects model. Of 529 true positive S. Typhi cases, 61 % (95 % CI 52-70 %) and 96 % (95 % CI 93-99 %) were detected by blood and bone marrow cultures respectively. Blood culture sensitivity was 66 % (95 % CI 56-75 %) when compared with bone marrow culture results. The use of blood culture sensitivity as a proxy measure to estimate the proportion of typhoid fever cases detected by blood culture is likely to be an underestimate. As blood culture sensitivity is used as a correction factor in estimating typhoid disease burden, epidemiologists and policy makers should account for the underestimation.

  12. Blood cultures for women hospitalized with acute pelvic inflammatory disease. Are they necessary?

    PubMed

    Apuzzio, J J; Hessami, S; Rodriguez, P

    2001-09-01

    To determine the incidence of positive blood cultures and if the results affect the clinical management or the duration of hospital stay in patients with acute pelvic inflammatory disease (PID). Retrospective study of all patients hospitalized with a diagnosis of acute PID from January 1, 1996, to December 31, 1997. Of 93 patients in the study, 3 had significant bacterial growth from blood culture specimens. The results of blood culture specimens did not affect clinical management. Routine specimens for blood culture may not be needed from patients hospitalized with acute PID.

  13. Quantitative targeted proteomics for understanding the blood-brain barrier: towards pharmacoproteomics.

    PubMed

    Ohtsuki, Sumio; Hirayama, Mio; Ito, Shingo; Uchida, Yasuo; Tachikawa, Masanori; Terasaki, Tetsuya

    2014-06-01

    The blood-brain barrier (BBB) is formed by brain capillary endothelial cells linked together via complex tight junctions, and serves to prevent entry of drugs into the brain. Multiple transporters are expressed at the BBB, where they control exchange of materials between the circulating blood and brain interstitial fluid, thereby supporting and protecting the CNS. An understanding of the BBB is necessary for efficient development of CNS-acting drugs and to identify potential drug targets for treatment of CNS diseases. Quantitative targeted proteomics can provide detailed information on protein expression levels at the BBB. The present review highlights the latest applications of quantitative targeted proteomics in BBB research, specifically to evaluate species and in vivo-in vitro differences, and to reconstruct in vivo transport activity. Such a BBB quantitative proteomics approach can be considered as pharmacoproteomics.

  14. Simple method for culture of peripheral blood lymphocytes of Testudinidae.

    PubMed

    Silva, T L; Silva, M I A; Venancio, L P R; Zago, C E S; Moscheta, V A G; Lima, A V B; Vizotto, L D; Santos, J R; Bonini-Domingos, C R; Azeredo-Oliveira, M T V

    2011-12-06

    We developed and optimized a simple, efficient and inexpensive method for in vitro culture of peripheral blood lymphocytes from the Brazilian tortoise Chelonoidis carbonaria (Testudinidae), testing various parameters, including culture medium, mitogen concentration, mitotic index, culture volume, incubation time, and mitotic arrest. Peripheral blood samples were obtained from the costal vein of four couples. The conditions that gave a good mitotic index were lymphocytes cultured at 37°C in minimum essential medium (7.5 mL), with phytohemagglutinin as a mitogen (0.375 mL), plus streptomycin/penicillin (0.1 mL), and an incubation period of 72 h. Mitotic arrest was induced by 2-h exposure to colchicine (0.1 mL), 70 h after establishing the culture. After mitotic arrest, the cells were hypotonized with 0.075 M KCl for 2 h and fixed with methanol/acetic acid (3:1). The non-banded mitotic chromosomes were visualized by Giemsa staining. The diploid chromosome number of C. carbonaria was found to be 52 in females and males, and sex chromosomes were not observed. We were able to culture peripheral blood lymphocytes of a Brazilian tortoise in vitro, for the preparation of mitotic chromosomes.

  15. A rapid, highly sensitive and culture-free detection of pathogens from blood by positive enrichment.

    PubMed

    Vutukuru, Manjula Ramya; Sharma, Divya Khandige; Ragavendar, M S; Schmolke, Susanne; Huang, Yiwei; Gumbrecht, Walter; Mitra, Nivedita

    2016-12-01

    Molecular diagnostics is a promising alternative to culture based methods for the detection of bloodstream infections, notably due to its overall lower turnaround time when starting directly from patient samples. Whole blood is usually the starting diagnostic sample in suspected bloodstream infections. The detection of low concentrations of pathogens in blood using a molecular assay necessitates a fairly high starting volume of blood sample in the range of 5-10mL. This large volume of blood sample has a substantial accompanying human genomic content that interferes with pathogen detection. In this study, we have established a workflow using magnetic beads coated with Apolipoprotein H that makes it possible to concentrate pathogens from a 5.0mL whole blood sample, thereby enriching pathogens from whole blood background and also reducing the sample volume to ~200μL or less. We have also demonstrated that this method of enrichment allows detection of 1CFU/mL of Escherichia coli, Enterococcus gallinarum and Candida tropicalis from 5mL blood using quantitative PCR; a detection limit that is not possible in unenriched samples. The enrichment method demonstrated here took 30min to complete and can be easily integrated with various downstream molecular and microbiological techniques. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Culturally Sensitive Parent Education: A Critical Review of Quantitative Research.

    ERIC Educational Resources Information Center

    Gorman, Jean Cheng; Balter, Lawrence

    1997-01-01

    Critically reviews the quantitative literature on culturally sensitive parent education programs, discussing issues of research methodology and program efficacy in producing change among ethnic minority parents and their children. Culturally sensitive programs for African American and Hispanic families are described in detail. Methodological flaws…

  17. Clinical impact of reducing routine blood culture incubation time from 7 to 5 days.

    PubMed

    Marginson, Michael J; Daveson, Kathryn L; Kennedy, Karina J

    2014-12-01

    The aim of this study was to determine the clinical impact of reducing the blood culture incubation protocol from 7 to 5 days.A laboratory data extraction identified positive blood cultures occurring after 5 or more days of incubation at Canberra Hospital, Australia between 1 January 2001 and 31 August 2011. Isolates were identified as clinically significant using a pre-existing prospective bacteraemia database. Medical records review determined whether the positive result affected clinical management.Positive blood cultures after 5 or more days of incubation accounted for 2.65% (423/15979) of all positive blood cultures, although the majority were false positives or contaminants. Eighty-five were significant/indeterminate, representing an average of eight cases per year or 0.47% (85/15979) of all positive blood cultures sets. Forty-three were isolated for the first time, representing 1.1% of all significant/indeterminate blood culture episodes. Fungi and anaerobic bacteria compromised over 50% of isolates. In 26 cases (2.4 cases per year), the culture result led to a change in patient management.A 7 day incubation protocol is preferable due to late isolation of organisms; however, if space is required to accommodate increasing blood culture numbers, reducing to a 5 or 6 day protocol would miss only a small percentage of clinically significant isolates.

  18. Blood culture contamination in hospitalized pediatric patients: a single institution experience

    PubMed Central

    Min, Hyewon; Park, Cheong Soo; Kim, Dong Soo

    2014-01-01

    Purpose Blood culture is the most important tool for detecting bacteremia in children with fever. However, blood culture contamination rates range from 0.6% to 6.0% in adults; rates for young children have been considered higher than these, although data are limited, especially in Korea. This study determined the contamination rate and risk factors in pediatric patients visiting the emergency room (ER) or being admitted to the ward. Methods We conducted a retrospective chart review of blood cultures obtained from children who visited Yonsei Severance Hospital, Korea between 2006 and 2010. Positive blood cultures were labeled as true bacteremia or contamination according to Centers for Disease Control and Prevention/National Healthcare Safety Network definitions for laboratory-confirmed bloodstream infection, after exclusion of cultures drawn from preexisting central lines only. Results Among 40,542 blood cultures, 610 were positive, of which 479 were contaminations and 131 were true bacteremia (overall contamination rate, 1.18%). The contamination rate in the ER was significantly higher than in the ward (1.32% vs. 0.66%, P<0.001). The rate was higher in younger children (2.07%, 0.94%, and 0.61% in children aged <1 year, 1-6 years, and >6 years, respectively). Conclusion Overall, contamination rates were higher in younger children than in older children, given the difficulty of performing blood sampling in younger children. The contamination rates from the ER were higher than those from the ward, not accounted for only by overcrowding and lack of experience among personnel collecting samples. Further study to investigate other factors affecting contamination should be required. PMID:24868215

  19. Real-time quantitative fluorescence measurement of microscale cell culture analog systems

    NASA Astrophysics Data System (ADS)

    Oh, Taek-il; Kim, Donghyun; Tatosian, Daniel; Sung, Jong Hwan; Shuler, Michael

    2007-02-01

    A microscale cell culture analog (μCCA) is a cell-based lab-on-a-chip assay that, as an animal surrogate, is applied to pharmacological studies for toxicology tests. A μCCA typically comprises multiple chambers and microfluidics that connect the chambers, which represent animal organs and blood flow to mimic animal metabolism more realistically. A μCCA is expected to provide a tool for high-throughput drug discovery. Previously, a portable fluorescence detection system was investigated for a single μCCA device in real-time. In this study, we present a fluorescence-based imaging system that provides quantitative real-time data of the metabolic interactions in μCCAs with an emphasis on measuring multiple μCCA samples simultaneously for high-throughput screening. The detection system is based on discrete optics components, with a high-power LED and a charge-coupled device (CCD) camera as a light source and a detector, for monitoring cellular status on the chambers of each μCCA sample. Multiple samples are characterized mechanically on a motorized linear stage, which is fully-automated. Each μCCA sample has four chambers, where cell lines MES-SA/DX- 5, and MES-SA (tumor cells of human uterus) have been cultured. All cell-lines have been transfected to express the fusion protein H2B-GFP, which is a human histone protein fused at the amino terminus to EGFP. As a model cytotoxic drug, 10 μM doxorubicin (DOX) was used. Real-time quantitative data of the intensity loss of enhanced green fluorescent protein (EGFP) during cell death of target cells have been collected over several minutes to 40 hours. Design issues and improvements are also discussed.

  20. [EXPRESS IDENTIFICATION OF POSITIVE BLOOD CULTURES USING DIRECT MALDI-TOF MASS SPECTROMETRY].

    PubMed

    Popov, D A; Ovseenko, S T; Vostrikova, T Yu

    2015-01-01

    To evaluate the effectiveness of direct identification of pathogens of bacteremia by direct matrix assisted laser desorption ionization time-flight mass spectrometry (mALDI-TOF) compared to routine method. A prospective study included 211 positive blood cultures obtained from 116 patients (106 adults and 10 children, aged from 2 weeks to 77 years old in the ICU after open heart surgery. Incubation was carried out under aerobic vials with a sorbent for antibiotics Analyzer BacT/ALERT 3D 120 (bioMerieux, France) in parallel with the primary sieving blood cultures on solid nutrient media with subsequent identification of pure cultures using MALDI-TOF mass spectrometry analyzer Vitek MS, bioMerieux, France routine method), after appropriate sample preparation we carried out a direct (without screening) MALDI-TOF mass spectrometric study of monocomponental blood cultures (n = 201). using a routine method in 211 positive blood cultures we identified 23 types of microorganisms (Staphylococcus (n = 87), Enterobacteria- ceae (n = 71), Enterococci (n = 20), non-fermentative Gram-negative bacteria (n = 18), others (n = 5). The average time of incubation of samples to obtain a signal of a blood culture growth was 16.2 ± 7.4 h (from 3.75 to 51 hours.) During the first 12 hours of incubation, growth was obtained in 32.4% of the samples, and on the first day in 92.2%. In the direct mass spectrometric analysis mnonocomponental blood cultures (n = 201) is well defined up to 153 species of the sample (76.1%), while the share of successful identification of Gram-negative bacteria was higher than that of Gram-positive (85.4 and 69, 1%, respectively p = 0.01). The high degree of consistency in the results of standard and direct method of identifying blood cultures using MALDI-TOF mass spectrometry (κ = 0.96, p < 0.001; the samples included in the calculation for which both option given result). Duration of the direct mass spectrometric analysis, including sample preparation, was no

  1. Role of quantitative CSF microscopy to predict culture status and outcome in HIV-associated cryptococcal meningitis in a Brazilian cohort.

    PubMed

    Vidal, José E; Gerhardt, Juliana; Peixoto de Miranda, Erique J; Dauar, Rafi F; Oliveira Filho, Gilberto S; Penalva de Oliveira, Augusto C; Boulware, David R

    2012-05-01

    This retrospective study aimed to evaluate the clinical, laboratory, and quantitative cerebrospinal fluid (CSF) cryptococcal cell counts for associations with in-hospital outcomes of HIV-infected patients with cryptococcal meningitis. Ninety-eight HIV-infected adult patients with CSF culture-proven cryptococcal meningitis were admitted between January 2006 and June 2008 at a referral center in Sao Paulo, Brazil. Cryptococcal meningitis was the first AIDS-defining illness in 69%, of whom 97% (95/98) had known prior HIV infection. The median CD4+ T-cell count was 39 cells/μL (interquartile range 17-87 cells/μL). Prior antiretroviral therapy was reported in 50%. Failure to sterilize the CSF by 7-14 days was associated with baseline fungal burden of ≥ 10 yeasts/μL by quantitative CSF microscopy (odds ratio [OR] = 15.3, 95% confidence interval [CI] 4.1-56.7; P < 0.001) and positive blood cultures (OR = 11.5, 95% CI 1.2-109; P = 0.034). At 7-14 days, ≥ 10 yeasts/μL CSF was associated with positive CSF cultures in 98% versus 36% with <10 yeasts/μL CSF (P < 0.001). In-hospital mortality was 30% and was associated with symptoms duration for >14 days, altered mental status (P < 0.001), CSF white blood cell counts <5 cells/μL (P = 0.027), intracranial hypertension (P = 0.011), viral loads >50,000 copies/mL (P = 0.036), ≥ 10 yeasts/μL CSF at 7-14 days (P = 0.038), and intracranial pressure >50 cmH(2)0 at 7-14 days (P = 0.007). In conclusion, most patients were aware of their HIV status. Fungal burden of ≥ 10 yeasts/μL by quantitative CSF microscopy predicted current CSF culture status and may be useful to customize the induction therapy. High uncontrolled intracranial pressure was associated with mortality. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Improved Diagnosis of Prosthetic Joint Infection by Culturing Periprosthetic Tissue Specimens in Blood Culture Bottles.

    PubMed

    Peel, Trisha N; Dylla, Brenda L; Hughes, John G; Lynch, David T; Greenwood-Quaintance, Kerryl E; Cheng, Allen C; Mandrekar, Jayawant N; Patel, Robin

    2016-01-05

    Despite known low sensitivity, culture of periprosthetic tissue specimens on agars and in broths is routine. Culture of periprosthetic tissue samples in blood culture bottles (BCBs) is potentially more convenient, but it has been evaluated in a limited way and has not been widely adopted. The aim of this study was to compare the sensitivity and specificity of inoculation of periprosthetic tissue specimens into blood culture bottles with standard agar and thioglycolate broth culture, applying Bayesian latent class modeling (LCM) in addition to applying the Infectious Diseases Society of America (IDSA) criteria for prosthetic joint infection. This prospective cohort study was conducted over a 9-month period (August 2013 to April 2014) at the Mayo Clinic, Rochester, MN, and included all consecutive patients undergoing revision arthroplasty. Overall, 369 subjects were studied; 117 (32%) met IDSA criteria for prosthetic joint infection, and 82% had late chronic infection. Applying LCM, inoculation of tissues into BCBs was associated with a 47% improvement in sensitivity compared to the sensitivity of conventional agar and broth cultures (92.1 versus 62.6%, respectively); this magnitude of change was similar when IDSA criteria were applied (60.7 versus 44.4%, respectively; P = 0.003). The time to microorganism detection was shorter with BCBs than with standard media (P < 0.0001), with aerobic and anaerobic BCBs yielding positive results within a median of 21 and 23 h, respectively. Results of our study demonstrate that the semiautomated method of periprosthetic tissue culture in blood culture bottles is more sensitive than and as specific as agar and thioglycolate broth cultures and yields results faster. Prosthetic joint infections are a devastating complication of arthroplasty surgery. Despite this, current microbiological techniques to detect and diagnose infections are imperfect. This study examined a new approach to diagnosing infections, through the inoculation of

  3. Improved Diagnosis of Prosthetic Joint Infection by Culturing Periprosthetic Tissue Specimens in Blood Culture Bottles

    PubMed Central

    Peel, Trisha N.; Dylla, Brenda L.; Hughes, John G.; Lynch, David T.; Greenwood-Quaintance, Kerryl E.; Cheng, Allen C.; Mandrekar, Jayawant N.

    2016-01-01

    ABSTRACT Despite known low sensitivity, culture of periprosthetic tissue specimens on agars and in broths is routine. Culture of periprosthetic tissue samples in blood culture bottles (BCBs) is potentially more convenient, but it has been evaluated in a limited way and has not been widely adopted. The aim of this study was to compare the sensitivity and specificity of inoculation of periprosthetic tissue specimens into blood culture bottles with standard agar and thioglycolate broth culture, applying Bayesian latent class modeling (LCM) in addition to applying the Infectious Diseases Society of America (IDSA) criteria for prosthetic joint infection. This prospective cohort study was conducted over a 9-month period (August 2013 to April 2014) at the Mayo Clinic, Rochester, MN, and included all consecutive patients undergoing revision arthroplasty. Overall, 369 subjects were studied; 117 (32%) met IDSA criteria for prosthetic joint infection, and 82% had late chronic infection. Applying LCM, inoculation of tissues into BCBs was associated with a 47% improvement in sensitivity compared to the sensitivity of conventional agar and broth cultures (92.1 versus 62.6%, respectively); this magnitude of change was similar when IDSA criteria were applied (60.7 versus 44.4%, respectively; P = 0.003). The time to microorganism detection was shorter with BCBs than with standard media (P < 0.0001), with aerobic and anaerobic BCBs yielding positive results within a median of 21 and 23 h, respectively. Results of our study demonstrate that the semiautomated method of periprosthetic tissue culture in blood culture bottles is more sensitive than and as specific as agar and thioglycolate broth cultures and yields results faster. PMID:26733067

  4. Effect of a training programme on blood culture contamination rate in critical care.

    PubMed

    Sánchez-Sánchez, M M; Arias-Rivera, S; Fraile-Gamo, P; Jareño-Collado, R; López-Román, S; Vadillo-Obesso, P; García-González, S; Pulido-Martos, M T; Sánchez-Muñoz, E I; Cacho-Calvo, J; Martín-Pellicer, A; Panadero-Del Olmo, L; Frutos-Vivar, F

    2018-03-30

    Blood culture contamination can occur from extraction to processing; its rate should not exceed 3%. To evaluate the impact of a training programme on the rate of contaminated blood cultures after the implementation of sample extraction recommendations based on the best evidence. Prospective before-after study in a polyvalent intensive care unit with 18 beds. Two phases were established (January-June 2012, October 2012-October 2015) with a training period between them. Main recommendations: sterile technique, surgical mask, double skin disinfection (70° alcohol and 2% alcoholic chlorhexidine), 70° alcohol disinfection of culture flasks and injection of samples without changing needles. Including all blood cultures of patients with extraction request. demographic, severity, pathology, reason for admission, stay and results of blood cultures (negative, positive and contaminated). Basic descriptive statistics: mean (standard deviation), median (interquartile range) and percentage (95% confidence interval). Calculated contamination rates per 100 blood cultures extracted. Bivariate analysis between periods. Four hundred and eight patients were included. Eight hundred and forty-one blood cultures were taken, 33 of which were contaminated. In the demographic variables, severity, diagnosis and stay of patients with contaminated samples, no differences were observed from those with uncontaminated samples. Pre-training vs post-training contamination rates: 14 vs 5.6 per 100 blood cultures extracted (P=.00003). An evidence-based training programme reduced the contamination of samples. It is necessary to continue working on the planning of activities and care to improve the detection of pollutants and prevent contamination of samples. Copyright © 2018 Sociedad Española de Enfermería Intensiva y Unidades Coronarias (SEEIUC). Publicado por Elsevier España, S.L.U. All rights reserved.

  5. Rapid Identification of Pathogens from Positive Blood Cultures by Multiplex PCR using the FilmArray System

    PubMed Central

    Blaschke, Anne J.; Heyrend, Caroline; Byington, Carrie L.; Fisher, Mark A.; Barker, Elizabeth; Garrone, Nicholas F.; Thatcher, Stephanie A.; Pavia, Andrew T.; Barney, Trenda; Alger, Garrison D.; Daly, Judy A.; Ririe, Kirk M.; Ota, Irene; Poritz, Mark A.

    2012-01-01

    Sepsis is a leading cause of death. Rapid and accurate identification of pathogens and antimicrobial resistance directly from blood culture could improve patient outcomes. The FilmArray® (FA; Idaho Technology, Inc., Salt Lake City, UT) Blood Culture (BC) panel can identify > 25 pathogens and 4 antibiotic resistance genes from positive blood cultures in 1 hour. We compared a development version of the panel to conventional culture and susceptibility testing on 102 archived blood cultures from adults and children with bacteremia. Of 109 pathogens identified by culture, 95% were identified by FA. Among 111 prospectively collected blood cultures, the FA identified 84 of 92 pathogens (91%) covered by the panel. Among 25 Staphylococcus aureus and 21 Enterococcus species detected, FA identified all culture-proven MRSA and VRE. The FA BC panel is an accurate method for the rapid identification of pathogens and resistance genes from blood culture. PMID:22999332

  6. Evaluating the use of blood cultures in the management of children hospitalized for community-acquired pneumonia.

    PubMed

    McCulloh, Russell J; Koster, Michael P; Yin, Dwight E; Milner, Tiffany L; Ralston, Shawn L; Hill, Vanessa L; Alverson, Brian K; Biondi, Eric A

    2015-01-01

    Blood cultures are often recommended for the evaluation of community-acquired pneumonia (CAP). However, institutions vary in their use of blood cultures, and blood cultures have unclear utility in CAP management in hospitalized children. To identify clinical factors associated with obtaining blood cultures in children hospitalized with CAP, and to estimate the association between blood culture obtainment and hospital length of stay (LOS). We performed a multicenter retrospective cohort study of children admitted with a diagnosis of CAP to any of four pediatric hospitals in the United States from January 1, 2011-December 31, 2012. Demographics, medical history, diagnostic testing, and clinical outcomes were abstracted via manual chart review. Multivariable logistic regression evaluated patient and clinical factors for associations with obtaining blood cultures. Propensity score-matched Kaplan-Meier analysis compared patients with and without blood cultures for hospital LOS. Six hundred fourteen charts met inclusion criteria; 390 children had blood cultures obtained. Of children with blood cultures, six (1.5%) were positive for a pathogen and nine (2.3%) grew a contaminant. Factors associated with blood culture obtainment included presenting with symptoms of systemic inflammatory response syndrome (OR 1.78, 95% CI 1.10-2.89), receiving intravenous hydration (OR 3.94, 95% CI 3.22-4.83), receiving antibiotics before admission (OR 1.49, 95% CI 1.17-1.89), hospital admission from the ED (OR 1.65, 95% CI 1.05-2.60), and having health insurance (OR 0.42, 95% CI 0.30-0.60). In propensity score-matched analysis, patients with blood cultures had median 0.8 days longer LOS (2.0 vs 1.2 days, P < .0001) without increased odds of readmission (OR 0.94, 95% CI 0.45-1.97) or death (P = .25). Obtaining blood cultures in children hospitalized with CAP rarely identifies a causative pathogen and is associated with increased LOS. Our results highlight the need to refine the role of

  7. Diagnosis of blood culture-negative endocarditis and clinical comparison between blood culture-negative and blood culture-positive cases.

    PubMed

    Lamas, Cristiane C; Fournier, Pierre-Edouard; Zappa, Monica; Brandão, Tatiana J D; Januário-da-Silva, Carolina A; Correia, Marcelo G; Barbosa, Giovanna Ianini F; Golebiovski, Wilma F; Weksler, Clara; Lepidi, Hubert; Raoult, Didier

    2016-08-01

    To analyze the clinical characteristics of blood culture-negative endocarditis (BCNE) and how it compares to those of blood culture-positive endocarditis (BCPE) cases and show how molecular tools helped establish the etiology in BCNE. Adult patients with definite infective endocarditis (IE) and having valve surgery were included. Valves were studied by polymerase chain reaction (PCR). Statistical analysis compared BCNE and BCPE. One hundred and thirty-one patients were included; 53 (40 %) had BCNE. The mean age was 45 ± 16 years; 33 (62 %) were male. BCNE was community-acquired in 41 (79 %). Most patients were referred from other hospitals (38, 73 %). Presentation was subacute in 34 (65 %), with fever in 47/53 (90 %) and a new regurgitant murmur in 34/42 (81 %). Native valves were affected in 74 %, mostly left-sided. All echocardiograms showed major criteria for IE. Antibiotics were used prior to BC collection in 31/42 (74 %). Definite histological diagnosis was established for 35/50 (70 %) valves. PCR showed oralis group streptococci in 21 (54 %), S. aureus in 3 (7.7 %), gallolyticus group streptococci in 2 (5.1 %), Coxiella burnetii in 1 (2.5 %) and Rhizobium sp. in 1 (2.5 %). In-hospital mortality was 9/53 (17 %). Fever (p = 0.06, OR 4.7, CI 0.91-24.38) and embolic complications (p = 0.003, OR 3.3, CI 1.55-6.82) were more frequent in BCPE cases, while new acute regurgitation (p = 0.05, OR 0.3, CI 0.098-0.996) and heart failure (p = 0.02, OR 0.3, CI 0.13-0.79) were less so. BCNE resulted mostly from prior antibiotics and was associated with severe hemodynamic compromise. Valve histopathology and PCR were useful in confirming the diagnosis and pointing to the etiology of BCNE.

  8. Trypanosoma cruzi. Surface antigens of blood and culture forms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nogueira, N.; Chaplan, S.; Tydings, J.D.

    1981-03-01

    The surface polypeptides of both cultured and blood forms of Trypanosoma cruzi were iodinated by the glucose oxidase-lactoperoxidase technique. Blood-form trypomastigotes (BFT) isolated form infected mice displayed a major 90,000-Mr component. In contrast, both epimastigotes and trypomastigotes obtained form acellular cultures expressed a smaller 75,000-Mr peptide. Both major surface components were presumably glycoproteins in terms of their binding to concanavalin A-Sepharose 4B. Within a 3-h period, both blood and culture forms synthesized their respective surface glycoproteins (90,000 Mr and 75,000 Mr, respectively in vitro. (/sub 35/S)methionine-labeled surface peptides were immunoprecipitated with immune sera of both human and murine origin. Amore » panel of sera form patients with chronic Chagas' disease and hyperimmunized mice recognized similar surface peptides. These immunogens were the same components as the major iodinated species. The major BFT surface peptide was readily removed by trypsin treatment of the parasites, although the procedure did not affect the 75,000-Mr peptide from the culture forms. Two-dimensional polyacrylamide gel electrophoresis revealed that the 90,000-Mr peptide found on BFT was an acidic protein of isoelectric point (pI) 5.0, whereas, the 75,000-Mr peptide form culture-form trypomastigotes has a pI of 7.2. The 90,000-Mr component is thought to be responsible for the anti-phagocytic properties of the BFT (1).« less

  9. Reproducibility of CSF quantitative culture methods for estimating rate of clearance in cryptococcal meningitis.

    PubMed

    Dyal, Jonathan; Akampurira, Andrew; Rhein, Joshua; Morawski, Bozena M; Kiggundu, Reuben; Nabeta, Henry W; Musubire, Abdu K; Bahr, Nathan C; Williams, Darlisha A; Bicanic, Tihana; Larsen, Robert A; Meya, David B; Boulware, David R

    2016-05-01

    Quantitative cerebrospinal fluid (CSF) cultures provide a measure of disease severity in cryptococcal meningitis. The fungal clearance rate by quantitative cultures has become a primary endpoint for phase II clinical trials. This study determined the inter-assay accuracy of three different quantitative culture methodologies. Among 91 participants with meningitis symptoms in Kampala, Uganda, during August-November 2013, 305 CSF samples were prospectively collected from patients at multiple time points during treatment. Samples were simultaneously cultured by three methods: (1) St. George's 100 mcl input volume of CSF with five 1:10 serial dilutions, (2) AIDS Clinical Trials Group (ACTG) method using 1000, 100, 10 mcl input volumes, and two 1:100 dilutions with 100 and 10 mcl input volume per dilution on seven agar plates; and (3) 10 mcl calibrated loop of undiluted and 1:100 diluted CSF (loop). Quantitative culture values did not statistically differ between St. George-ACTG methods (P= .09) but did for St. George-10 mcl loop (P< .001). Repeated measures pairwise correlation between any of the methods was high (r≥0.88). For detecting sterility, the ACTG-method had the highest negative predictive value of 97% (91% St. George, 60% loop), but the ACTG-method had occasional (∼10%) difficulties in quantification due to colony clumping. For CSF clearance rate, St. George-ACTG methods did not differ overall (mean -0.05 ± 0.07 log10CFU/ml/day;P= .14) on a group level; however, individual-level clearance varied. The St. George and ACTG quantitative CSF culture methods produced comparable but not identical results. Quantitative cultures can inform treatment management strategies. © The Author 2016. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. Real time blood testing using quantitative phase imaging.

    PubMed

    Pham, Hoa V; Bhaduri, Basanta; Tangella, Krishnarao; Best-Popescu, Catherine; Popescu, Gabriel

    2013-01-01

    We demonstrate a real-time blood testing system that can provide remote diagnosis with minimal human intervention in economically challenged areas. Our instrument combines novel advances in label-free optical imaging with parallel computing. Specifically, we use quantitative phase imaging for extracting red blood cell morphology with nanoscale sensitivity and NVIDIA's CUDA programming language to perform real time cellular-level analysis. While the blood smear is translated through focus, our system is able to segment and analyze all the cells in the one megapixel field of view, at a rate of 40 frames/s. The variety of diagnostic parameters measured from each cell (e.g., surface area, sphericity, and minimum cylindrical diameter) are currently not available with current state of the art clinical instruments. In addition, we show that our instrument correctly recovers the red blood cell volume distribution, as evidenced by the excellent agreement with the cell counter results obtained on normal patients and those with microcytic and macrocytic anemia. The final data outputted by our instrument represent arrays of numbers associated with these morphological parameters and not images. Thus, the memory necessary to store these data is of the order of kilobytes, which allows for their remote transmission via, for example, the cellular network. We envision that such a system will dramatically increase access for blood testing and furthermore, may pave the way to digital hematology.

  11. Tumor necrosis factor-alpha (TNF-alpha) concentrations from whole blood cultures correlate with isolated peripheral blood mononuclear cell cultures

    USDA-ARS?s Scientific Manuscript database

    Many cellular immune assays are impractical because they require labor-intensive isolation of cells from their natural environment. The objectives of this study were to determine the relationship between cell culture supernatant TNF-alpha from isolated peripheral blood mononuclear cells (PBMC) and w...

  12. Minimizing the Workup of Blood Culture Contaminants: Implementation and Evaluation of a Laboratory-Based Algorithm

    PubMed Central

    Richter, S. S.; Beekmann, S. E.; Croco, J. L.; Diekema, D. J.; Koontz, F. P.; Pfaller, M. A.; Doern, G. V.

    2002-01-01

    An algorithm was implemented in the clinical microbiology laboratory to assess the clinical significance of organisms that are often considered contaminants (coagulase-negative staphylococci, aerobic and anaerobic diphtheroids, Micrococcus spp., Bacillus spp., and viridans group streptococci) when isolated from blood cultures. From 25 August 1999 through 30 April 2000, 12,374 blood cultures were submitted to the University of Iowa Clinical Microbiology Laboratory. Potential contaminants were recovered from 495 of 1,040 positive blood cultures. If one or more additional blood cultures were obtained within ±48 h and all were negative, the isolate was considered a contaminant. Antimicrobial susceptibility testing (AST) of these probable contaminants was not performed unless requested. If no additional blood cultures were submitted or there were additional positive blood cultures (within ±48 h), a pathology resident gathered patient clinical information and made a judgment regarding the isolate's significance. To evaluate the accuracy of these algorithm-based assignments, a nurse epidemiologist in approximately 60% of the cases performed a retrospective chart review. Agreement between the findings of the retrospective chart review and the automatic classification of the isolates with additional negative blood cultures as probable contaminants occurred among 85.8% of 225 isolates. In response to physician requests, AST had been performed on 15 of the 32 isolates with additional negative cultures considered significant by retrospective chart review. Agreement of pathology resident assignment with the retrospective chart review occurred among 74.6% of 71 isolates. The laboratory-based algorithm provided an acceptably accurate means for assessing the clinical significance of potential contaminants recovered from blood cultures. PMID:12089259

  13. All in the Blood: A Review of Aboriginal Australians' Cultural Beliefs About Blood and Implications for Biospecimen Research.

    PubMed

    Kowal, Emma; Greenwood, Ashley; McWhirter, Rebekah E

    2015-10-01

    Public participation in medical research and biobanking is considered key to advances in scientific discovery and translation to improved health care. Cultural concerns relating to blood have been found to affect the participation of indigenous peoples and minorities in research, but such concerns are rarely specified in the literature. This article presents a review of the role of blood in Australian Aboriginal cultures. We discuss the range of meanings and uses of blood in traditional culture, including their use in ceremonies, healing, and sorcery. We draw on more recent literature on Aboriginal Australians and biomedicine to consider how traditional beliefs may be changing over time. These findings provide an empirical basis for researchers and bioethicists to develop culturally grounded strategies to boost the participation of Aboriginal Australians in biomedical research. They also serve as a model for integrating anthropological literature with bioethical concerns that could be applied to other indigenous and minority groups. © The Author(s) 2015.

  14. Patient-specific coronary blood supply territories for quantitative perfusion analysis

    PubMed Central

    Zakkaroff, Constantine; Biglands, John D.; Greenwood, John P.; Plein, Sven; Boyle, Roger D.; Radjenovic, Aleksandra; Magee, Derek R.

    2018-01-01

    Abstract Myocardial perfusion imaging, coupled with quantitative perfusion analysis, provides an important diagnostic tool for the identification of ischaemic heart disease caused by coronary stenoses. The accurate mapping between coronary anatomy and under-perfused areas of the myocardium is important for diagnosis and treatment. However, in the absence of the actual coronary anatomy during the reporting of perfusion images, areas of ischaemia are allocated to a coronary territory based on a population-derived 17-segment (American Heart Association) AHA model of coronary blood supply. This work presents a solution for the fusion of 2D Magnetic Resonance (MR) myocardial perfusion images and 3D MR angiography data with the aim to improve the detection of ischaemic heart disease. The key contribution of this work is a novel method for the mediated spatiotemporal registration of perfusion and angiography data and a novel method for the calculation of patient-specific coronary supply territories. The registration method uses 4D cardiac MR cine series spanning the complete cardiac cycle in order to overcome the under-constrained nature of non-rigid slice-to-volume perfusion-to-angiography registration. This is achieved by separating out the deformable registration problem and solving it through phase-to-phase registration of the cine series. The use of patient-specific blood supply territories in quantitative perfusion analysis (instead of the population-based model of coronary blood supply) has the potential of increasing the accuracy of perfusion analysis. Quantitative perfusion analysis diagnostic accuracy evaluation with patient-specific territories against the AHA model demonstrates the value of the mediated spatiotemporal registration in the context of ischaemic heart disease diagnosis. PMID:29392098

  15. Contamination of blood cultures during venepuncture: fact or myth?

    PubMed Central

    Shahar, E.; Wohl-Gottesman, B. S.; Shenkman, L.

    1990-01-01

    Contamination of blood cultures is believed to occur mainly during the venepuncture procedure. Consequently, meticulous preparation of the venepuncture site is widely recommended. To determine whether the contamination rate is indeed affected by the quality of the antiseptic procedure at the venepuncture site, 181 paired cultures were collected from 176 patients during a 6-month period after either strict antiseptic cleansing of skin with alcohol followed by povidone-iodine, or after brief disinfection with alcohol alone. The contamination rate was not influenced by the antiseptic procedure, and corresponded to the accepted percentage reported in most other studies. Eight false positive cultures (4.4%) were obtained after strict antisepsis of the skin and 6 (3.3%) after short simple cleansing with alcohol (P = 0.39). Our results suggest that contamination of blood cultures may not be related to the venepuncture procedure--regardless of the antiseptic technique used--but may be due to later stages of laboratory handling and processing of the specimens. Review of the literature has provided further indirect evidence to support this conclusion. PMID:2084653

  16. Accuracy of blood culture for early diagnosis of mediastinitis in febrile patients after cardiac surgery.

    PubMed

    San Juan, R; Aguado, J M; López, M J; Lumbreras, C; Enriquez, F; Sanz, F; Chaves, F; López-Medrano, F; Lizasoain, M; Rufilanchas, J J

    2005-03-01

    Postsurgical mediastinitis (PSM) remains a major cause of morbidity and mortality in patients undergoing cardiac surgery procedures. Although prompt diagnosis is crucial in these patients, neither clinical data nor imaging techniques have shown enough sensitivity or specificity for early diagnosis of PSM. The aim of the present study was to assess the validity of blood cultures as a diagnostic test for the early detection of PSM in patients who become febrile after cardiac surgery procedures. During a 4-year period (1999-2002), patients who developed fever (>37.8 degrees C) in the first 60 days after a cardiac surgery procedure were evaluated. Blood cultures were drawn from these patients. PSM was defined as deep infection involving retrosternal tissue and/or the sternal bone directly observed by the surgeon and confirmed microbiologically. Three criteria for positivity of blood cultures were applied: bacteremia, staphylococcal bacteremia, or Staphylococcus aureus bacteremia. For purposes of the analysis, a positive blood culture in patients with PSM was considered a true-positive test and a negative blood culture a false-negative test. Otherwise, in febrile patients without PSM in the postsurgery period, a positive blood culture was considered a false-positive test and a negative blood culture a true-negative test. Blood cultures were drawn from 266 febrile patients in the postsurgery period. PSM occurred in 38 patients (26 cases due to S. aureus, 8 to Staphylococcus epidermidis, 3 to gram-negative enteric bacteria, and one to Pseudomonas aeruginosa). Within the 60-day postsurgical period, blood culture as a diagnostic test was most accurate in patients with S. aureus bacteremia, providing 68% sensitivity, 98% specificity, a positive predictive value of 87%, and a negative predictive value of 95%. If the analysis was limited to the period during which patients are at maximum risk for PSM (day 7-20), the values in patients with S. aureus bacteremia were as follows

  17. Trends in blood culture contamination: a College of American Pathologists Q-Tracks study of 356 institutions.

    PubMed

    Bekeris, Leonas G; Tworek, Joseph A; Walsh, Molly K; Valenstein, Paul N

    2005-10-01

    Blood culture contamination extends hospital stays and increases the cost of care. To measure blood culture contamination rates in a large number of institutions over time and to elucidate practice patterns and demographic factors associated with sustained reduction in contamination rates. Longitudinal cohort study of 356 clinical laboratories that provided quarterly data about blood culture results, using a uniform definition of contamination. Mixed linear model analysis of the 1999 through 2003 data set. Blood culture contamination was significantly higher in institutions that used nonlaboratory personnel to collect blood (P = .03) and significantly lower in facilities that used a dedicated phlebotomy team (P < .001). Higher volume of blood collection was significantly associated with lower contamination rates (P < .001). Continued participation in the Q-Tracks monitoring program was associated with significant and progressive reduction in contamination rates. By the fifth year of participation, the median institution had reduced its blood culture contamination rate by 0.67% (P < .001). Institutions that use decentralized patient-centered personnel rather than dedicated phlebotomy teams to collect blood cultures experience significantly higher contamination rates. Long-term monitoring of contamination is associated with sustained improvement in performance.

  18. A CZT-based blood counter for quantitative molecular imaging.

    PubMed

    Espagnet, Romain; Frezza, Andrea; Martin, Jean-Pierre; Hamel, Louis-André; Lechippey, Laëtitia; Beauregard, Jean-Mathieu; Després, Philippe

    2017-12-01

    Robust quantitative analysis in positron emission tomography (PET) and in single-photon emission computed tomography (SPECT) typically requires the time-activity curve as an input function for the pharmacokinetic modeling of tracer uptake. For this purpose, a new automated tool for the determination of blood activity as a function of time is presented. The device, compact enough to be used on the patient bed, relies on a peristaltic pump for continuous blood withdrawal at user-defined rates. Gamma detection is based on a 20 × 20 × 15 mm 3 cadmium zinc telluride (CZT) detector, read by custom-made electronics and a field-programmable gate array-based signal processing unit. A graphical user interface (GUI) allows users to select parameters and easily perform acquisitions. This paper presents the overall design of the device as well as the results related to the detector performance in terms of stability, sensitivity and energy resolution. Results from a patient study are also reported. The device achieved a sensitivity of 7.1 cps/(kBq/mL) and a minimum detectable activity of 2.5 kBq/ml for 18 F. The gamma counter also demonstrated an excellent stability with a deviation in count rates inferior to 0.05% over 6 h. An energy resolution of 8% was achieved at 662 keV. The patient study was conclusive and demonstrated that the compact gamma blood counter developed has the sensitivity and the stability required to conduct quantitative molecular imaging studies in PET and SPECT.

  19. Blood culture accuracy: discards from central venous catheters in pediatric oncology patients in the emergency department.

    PubMed

    Winokur, Elizabeth J; Pai, Debra; Rutledge, Dana N; Vogel, Kate; Al-Majid, Sadeeka; Marshall, Christine; Sheikewitz, Paul

    2014-07-01

    Lack of specific guidelines regarding collection of blood for culture from central venous catheters (CVCs) has led to inconsistencies in policies among hospitals. Currently, no specific professional or regulatory recommendations exist in relation to using, reinfusing, or discarding blood drawn from CVCs before drawing blood for a culture. Repeated wasting of blood may harm immunocompromised pediatric oncology patients. The purpose of this comparative study was to determine whether differences exist between blood cultures obtained from the first 5 mL of blood drawn from a CVC line when compared with the second 5 mL drawn. During 2009-2011, 62 pediatric oncology patients with CVCs and orders for blood cultures to determine potential sepsis were enrolled during ED visits. Trained study nurses aseptically drew blood and injected the normally discarded first 5 mL and the second specimen (usual care) into separate culture bottles. Specimens were processed in the microbiology laboratory per hospital policy. Positive cultures were evaluated to assess agreement between specimen results and to determine that the identified pathogen was not a contaminant. Out of 186 blood culture pairs, 4.8% demonstrated positive results. In all positive-positive matches, the normal discard specimen contained the same organism as the usual care specimen. In 4 matches, the normally discarded specimen demonstrated notably earlier time to positivity (4 to 31 hours) compared with the usual care specimen, which resulted in earlier initiation of definitive antibiotics. These findings support the accuracy of the specimen that is normally discarded and suggest the need to reconsider its use for blood culture testing. Copyright © 2014 Emergency Nurses Association. Published by Mosby, Inc. All rights reserved.

  20. Hub qualitative blood culture is useful for diagnosis of catheter-related infections in critically ill patients.

    PubMed

    Tanguy, Michèle; Seguin, Philippe; Laviolle, Bruno; Desbordes, Laurent; Mallédant, Yannick

    2005-05-01

    To assess clinical safety and accuracy of qualitative blood culture drawn through the hub for ruling out catheter-related infection (CRI). Prospective observational study in a surgical intensive care unit. All patients with sepsis of unknown origin and possibly due to a CRI. Blood culture drawn through a central venous catheter (CVC) just before the catheter was cultured. In 126 patients we investigated 135 cases of sepsis of unknown origin. Using a clinical and bacteriological approach as the reference, the performance of the CVC blood culture was evaluated by the calculation of sensitivity, specificity, and positive and negative predictive values. When CVC blood culture was positive, the time to positivity was considered. Using standard definitions, seven CRIs were diagnosed. CVC blood culture identified five CRIs including the three episodes of catheter-related bacteremia. The method missed two coagulase-negative staphylococcus CRIs without bacteremia. Thirteen false-positive results occurred, including seven bacteremias from a distant source. The CVC blood culture had a sensitivity of 71% (CI 30-95%), specificity of 90% (CI 83-94%), negative predictive value of 98% (CI 93-100%), and positive predictive value of 28% (CI 11-54%). In cases of catheter-related bacteremia the time to positivity of CVC blood culture was 24 h or less. Negative CVC blood culture at 24 h seems useful for management of CVC in selected critically ill surgical patients developing a clinical sepsis. The subsequent risk of catheter-related bacteremia cannot be excluded advocating for an uninterrupted clinical and bacteriological survey.

  1. Conceptual Diversity, Moderators, and Theoretical Issues in Quantitative Studies of Cultural Capital Theory

    ERIC Educational Resources Information Center

    Tan, Cheng Yong

    2017-01-01

    The present study reviewed quantitative empirical studies examining the relationship between cultural capital and student achievement. Results showed that researchers had conceptualized and measured cultural capital in different ways. It is argued that the more holistic understanding of the construct beyond highbrow cultural consumption must be…

  2. Quantitative volumetric Raman imaging of three dimensional cell cultures

    NASA Astrophysics Data System (ADS)

    Kallepitis, Charalambos; Bergholt, Mads S.; Mazo, Manuel M.; Leonardo, Vincent; Skaalure, Stacey C.; Maynard, Stephanie A.; Stevens, Molly M.

    2017-03-01

    The ability to simultaneously image multiple biomolecules in biologically relevant three-dimensional (3D) cell culture environments would contribute greatly to the understanding of complex cellular mechanisms and cell-material interactions. Here, we present a computational framework for label-free quantitative volumetric Raman imaging (qVRI). We apply qVRI to a selection of biological systems: human pluripotent stem cells with their cardiac derivatives, monocytes and monocyte-derived macrophages in conventional cell culture systems and mesenchymal stem cells inside biomimetic hydrogels that supplied a 3D cell culture environment. We demonstrate visualization and quantification of fine details in cell shape, cytoplasm, nucleus, lipid bodies and cytoskeletal structures in 3D with unprecedented biomolecular specificity for vibrational microspectroscopy.

  3. Direct Isolation of Candida spp. from Blood Cultures on the Chromogenic Medium CHROMagar Candida

    PubMed Central

    Horvath, Lynn L.; Hospenthal, Duane R.; Murray, Clinton K.; Dooley, David P.

    2003-01-01

    CHROMagar Candida is a selective and differential chromogenic medium that has been shown to be useful for identification of Candida albicans, Candida krusei, Candida tropicalis, and perhaps Candida glabrata. Colony morphology and color have been well defined when CHROMagar Candida has been used to isolate yeast directly from clinical specimens, including stool, urine, respiratory, vaginal, oropharyngeal, and esophageal sources. Direct isolation of yeast on CHROMagar Candida from blood cultures has not been evaluated. We evaluated whether the color and colony characteristics produced by Candida spp. on CHROMagar Candida were altered when yeasts were isolated directly from blood cultures. Fifty clinical isolates of Candida were inoculated into aerobic and anaerobic blood culture bottles and incubated at 35°C in an automated blood culture system. When growth was detected, an aliquot was removed and plated onto CHROMagar Candida. As a control, CHROMagar Candida plates were inoculated with the same isolate of yeast grown on Sabouraud dextrose agar simultaneously. No significant difference was detected in color or colony morphology between the blood and control isolates in any of the tested organisms. All C. albicans (n = 12), C. tropicalis (n = 12), C. glabrata (n = 9), and C. krusei (n = 5) isolates exhibited the expected species-specific colony characteristics and color, whether isolated directly from blood or from control cultures. CHROMagar Candida can be reliably used for direct isolation of yeast from blood cultures. Direct isolation could allow mycology laboratories to more rapidly identify Candida spp., enable clinicians to more quickly make antifungal agent selections, and potentially decrease patient morbidity and mortality. PMID:12791890

  4. Study of Umbilical Cord Blood Culture in Diagnosis of Early-onset Sepsis Among Newborns with High-risk Factors.

    PubMed

    Kalathia, Mitul Babubhai; Shingala, Prakash Ashokbhai; Parmar, Parin Niranjanbhai; Parikh, Yogesh Narenedrabhai; Kalathia, Ila Mitulkumar

    2013-10-01

    Blood culture is gold standard for diagnosis of neonatal sepsis. Low sensitivity of blood culture is usually due to small volume of blood sample, intrapartum antibiotics, and antibiotics given to newborn before sampling. We evaluated use of Umbilical cord blood culture (UCBC) in diagnosis of neonatal sepsis as compared to peripheral venous blood culture. This study was done in tertiary care teaching hospital during May-June 2012. A total of 45 newborns with presence of two or more risk factors of sepsis were included. Blood sample from placental end of umbilical cord was collected and cultured. Primary outcome was diagnosis of neonatal sepsis by use of umbilical cord blood sample as compared with venous blood sample. Secondary outcome was to compare organisms identified by UCBC and venous blood culture. Sensitivity, specificity, positive and negative predictive values of UCBC were calculated. A total of 24.44% (11 out of 45) high-risk newborns had positive UCBC. A total of 17.8% (8 out of 45) newborns had positive blood culture report. Organisms grown in UCBC were Pseudomonas (45%, 5 out of 11), Acinetobacter (27.27%, 3 out of 11), Escherichia coli (18.18%, 2 out of 11), and Klebsiella (9%, 1 out of 11). UCBC is a good method for diagnosis of neonatal sepsis among high-risk newborns as compared to venous blood culture with a sensitivity of 80% and specificity of 91.43%. Organisms grown are comparable to blood culture samples.

  5. Quantitative Analysis of the KSHV Transcriptome Following Primary Infection of Blood and Lymphatic Endothelial Cells

    PubMed Central

    Bruce, A. Gregory; Barcy, Serge; DiMaio, Terri; Gan, Emilia; Garrigues, H. Jacques; Lagunoff, Michael; Rose, Timothy M.

    2017-01-01

    The transcriptome of the Kaposi’s sarcoma-associated herpesvirus (KSHV/HHV8) after primary latent infection of human blood (BEC), lymphatic (LEC) and immortalized (TIME) endothelial cells was analyzed using RNAseq, and compared to long-term latency in BCBL-1 lymphoma cells. Naturally expressed transcripts were obtained without artificial induction, and a comprehensive annotation of the KSHV genome was determined. A set of unique coding sequence (UCDS) features and a process to resolve overlapping transcripts were developed to accurately quantitate transcript levels from specific promoters. Similar patterns of KSHV expression were detected in BCBL-1 cells undergoing long-term latent infections and in primary latent infections of both BEC and LEC cultures. High expression levels of poly-adenylated nuclear (PAN) RNA and spliced and unspliced transcripts encoding the K12 Kaposin B/C complex and associated microRNA region were detected, with an elevated expression of a large set of lytic genes in all latently infected cultures. Quantitation of non-overlapping regions of transcripts across the complete KSHV genome enabled for the first time accurate evaluation of the KSHV transcriptome associated with viral latency in different cell types. Hierarchical clustering applied to a gene correlation matrix identified modules of co-regulated genes with similar correlation profiles, which corresponded with biological and functional similarities of the encoded gene products. Gene modules were differentially upregulated during latency in specific cell types indicating a role for cellular factors associated with differentiated and/or proliferative states of the host cell to influence viral gene expression. PMID:28335496

  6. Screening hypochromism (sieve effect) in red blood cells: a quantitative analysis

    PubMed Central

    Razi Naqvi, K.

    2014-01-01

    Multiwavelength UV-visible spectroscopy, Kramers-Kronig analysis, and several other experimental and theoretical tools have been applied over the last several decades to fathom absorption and scattering of light by suspensions of micron-sized pigmented particles, including red blood cells, but a satisfactory quantitative analysis of the difference between the absorption spectra of suspension of intact and lysed red blood cells is still lacking. It is stressed that such a comparison is meaningful only if the pertinent spectra are free from, or have been corrected for, scattering losses, and it is shown that Duysens’ theory can, whereas that of Vekshin cannot, account satisfactorily for the observed hypochromism of suspensions of red blood cells. PMID:24761307

  7. Screening hypochromism (sieve effect) in red blood cells: a quantitative analysis.

    PubMed

    Razi Naqvi, K

    2014-04-01

    Multiwavelength UV-visible spectroscopy, Kramers-Kronig analysis, and several other experimental and theoretical tools have been applied over the last several decades to fathom absorption and scattering of light by suspensions of micron-sized pigmented particles, including red blood cells, but a satisfactory quantitative analysis of the difference between the absorption spectra of suspension of intact and lysed red blood cells is still lacking. It is stressed that such a comparison is meaningful only if the pertinent spectra are free from, or have been corrected for, scattering losses, and it is shown that Duysens' theory can, whereas that of Vekshin cannot, account satisfactorily for the observed hypochromism of suspensions of red blood cells.

  8. Blood culture contamination in Tanzania, Malawi, and the United States: a microbiological tale of three cities.

    PubMed

    Archibald, Lennox K; Pallangyo, Kisali; Kazembe, Peter; Reller, L Barth

    2006-12-01

    We conducted retrospective, comparative analyses of contamination rates for cultures of blood obtained in the emergency rooms of Muhimbili National Hospital (MNH) in Dar es Salaam, Tanzania; Lilongwe Central Hospital (LCH) in central Malawi; and the Duke University Medical Center (DUMC) in the United States. None of the emergency room patients had indwelling intravascular devices at the time that the blood samples for cultures were obtained. In addition, we reviewed the contamination rates for a cohort of patients already hospitalized in the DUMC inpatient medical service, most of whom had indwelling intravascular devices. The bloodstream infection rates among the patients at MNH (n=513) and LCH (n=486) were similar (approximately 28%); the contamination rates at the two hospitals were 1.3% (7/513) and 0.8% (4/486), respectively. Of 54 microorganisms isolated from cultures of blood collected in the DUMC emergency room, 26 (48%) were identified as skin contaminants. Cultures of blood collected in the DUMC emergency room were significantly more likely to yield growth of contaminants than the cultures of blood collected in the emergency rooms at MNH and LCH combined (26/332 versus 11/1,003; P<0.0001) or collected in the DUMC inpatient medical service (26/332 versus 7/283; P<0.01). For the MNH and LCH blood cultures, lower contamination rates were observed when skin was disinfected with isopropyl alcohol plus tincture of iodine rather than isopropyl alcohol plus povidone-iodine. In conclusion, blood culture contamination was minimized in sub-Saharan African hospitals with substantially limited resources through scrupulous attention to aseptic skin cleansing and improved venipuncture techniques. Application of these principles when blood samples for culture are obtained in U.S. hospital emergency rooms should help mitigate blood culture contamination rates and the unnecessary microbiology workup of skin contaminants.

  9. [Prospective evaluation of blood cultures in Medical Faculty Hospital of Blacksea Technical University].

    PubMed

    Sucu, Nurgün; Caylan, Rahmet; Aydin, Kemalettin; Yilmaz, Gürdal; Aktoz Boz, Gönülden; Köksal, Iftihar

    2005-10-01

    In this study, the rate of blood culture contamination, bacterial pathogens and their antimicrobial susceptibilities causing nosocomial and community acquired bloodstream infections were investigated prospectively during the period February 2003 to February 2004. In the study period, among the 5994 blood culture samples obtained from 3114 patients, 1091 (18%) yielded positive results. Seventy-four of them (1.2%) were evaluated as false positive, 514 (9%) were pseudobacteremia or contamination. According to patients' clinical features, 503 (8%) blood culture samples were associated with blood stream infections, and 358 of them (71%) were primary episodes. Twohundred and ninetyfour of primary episodes (82%) were hospital acquired and 64 were community acquired bloodstream infections. Staphylococcus aureus was the most frequently isolated agent in the hospital and community acquired bloodstream infections at the rates of 16% and 20%, respectively. In hospital acquired blood stream infections, Escherichia coil (9%) and Pseudomonas aeruginosa (8%); in community acquired bloodstream infections Streptococcus spp (17%) and E. coli (15%) were the other most frequently isolated bacterial agents. Methicillin resistance of S. aureus isolates was determined as 54% in hospital acquired blood stream infections and 25% in community acquired blood stream infections.

  10. [Blood culture negative endocarditis: a diagnostic challenge].

    PubMed

    Wälli, F; Chuard, C; Regamey, C

    2005-10-12

    Blood culture negative endocarditis (BCNE) account for about 5% of all cases of endocarditis. Diagnosis and initiation of antimicrobial therapy may be delayed, with a negative impact on clinical outcome. The most common cause of BCNE is antimicrobial drug therapy before blood sampling. Other common causes include slow growing and non cultivable organisms. Identification of the etiologic agent is critical in the management of BCNE and molecular tools such as broad range 16SrRNA PCR technique followed by direct automated sequencing and microorganism-specific PCR are promising. Some authors have proposed to include these techniques among major Duke's criteria for the diagnosis of BCNE.

  11. Reducing Blood Culture Contamination in the Emergency Department: An Interrupted Time Series Quality Improvement Study

    PubMed Central

    Self, Wesley H.; Speroff, Theodore; Grijalva, Carlos G.; McNaughton, Candace D.; Ashburn, Jacki; Liu, Dandan; Arbogast, Patrick G.; Russ, Stephan; Storrow, Alan B.; Talbot, Thomas R.

    2012-01-01

    Objectives Blood culture contamination is a common problem in the emergency department (ED) that leads to unnecessary patient morbidity and health care costs. The study objective was to develop and evaluate the effectiveness of a quality improvement (QI) intervention for reducing blood culture contamination in an ED. Methods The authors developed a QI intervention to reduce blood culture contamination in the ED and then evaluated its effectiveness in a prospective interrupted times series study. The QI intervention involved changing the technique of blood culture specimen collection from the traditional clean procedure, to a new sterile procedure, with standardized use of sterile gloves and a new materials kit containing a 2% chlorhexidine skin antisepsis device, a sterile fenestrated drape, a sterile needle, and a procedural checklist. The intervention was implemented in a university-affiliated ED and its effect on blood culture contamination evaluated by comparing the biweekly percentages of blood cultures contaminated during a 48-week baseline period (clean technique), and 48-week intervention period (sterile technique), using segmented regression analysis with adjustment for secular trends and first-order autocorrelation. The goal was to achieve and maintain a contamination rate below 3%. Results During the baseline period, 321 out of 7,389 (4.3%) cultures were contaminated, compared to 111 of 6,590 (1.7%) during the intervention period (p < 0.001). In the segmented regression model, the intervention was associated with an immediate 2.9% (95% CI = 2.2% to 3.2%) absolute reduction in contamination. The contamination rate was maintained below 3% during each biweekly interval throughout the intervention period. Conclusions A QI assessment of ED blood culture contamination led to development of a targeted intervention to convert the process of blood culture collection from a clean to a fully sterile procedure. Implementation of this intervention led to an immediate

  12. Significance of coagulase negative Staphylococcus from blood cultures: persisting problems and partial progress in resource constrained settings.

    PubMed

    Sidhu, Shailpreet K; Malhotra, Sita; Devi, Pushpa; Tuli, Arpandeep K

    2016-12-01

    Coagulase negative Staphylococcus (CoNS) is frequently isolated from blood cultures but their significance is difficult to interpret. CoNS bacteria which are often previously dismissed as culture contaminants are attracting greater importance as true pathogens in the past decades. Clinical evaluation of these isolates suggests that although there is a relative increase of CoNS associated bloodstream infections in recent years, the microorganisms still remain the most common contaminants in blood cultures. The objective of this study was to determine the significance of CoNS isolated from blood cultures. A retrospective study was conducted to evaluate the rate of contamination in blood cultures in a tertiary care hospital. The paired specimens of blood were cultured using conventional culture methods and the isolates of coagulase negative staphylococci were identified by standard methodology. Clinical data, laboratory indices, microbiological parameters and patient characteristics were analyzed. Of 3503 blood samples, CoNS were isolated from blood culture of 307 patients (8.76%). The isolates were reported as true pathogens of bloodstream infections in only 74 out of 307 cases (24.1%). In the vast majority, 212 of 307 (69.0%), they were mere blood culture contaminants and reported as insignificant/contaminant. Determining whether a growth in the blood culture is a pathogen or a contaminant is a critical issue and multiple parameters have to be considered before arriving at a conclusion. Ideally, the molecular approach is for the most part a consistent method in determining the significant isolates of CoNS. However, in countries with inadequate resources, species identification and antibiogram tests are recommended when determining significance of these isolates.

  13. Blood Culture Testing via a Mobile App That Uses a Mobile Phone Camera: A Feasibility Study

    PubMed Central

    Chong, Yong Pil; Jang, Seongsoo; Kim, Mi Na; Kim, Jeong Hoon; Kim, Woo Sung

    2016-01-01

    Background To evaluate patients with fever of unknown origin or those with suspected bacteremia, the precision of blood culture tests is critical. An inappropriate step in the test process or error in a parameter could lead to a false-positive result, which could then affect the direction of treatment in critical conditions. Mobile health apps can be used to resolve problems with blood culture tests, and such apps can hence ensure that point-of-care guidelines are followed and processes are monitored for blood culture tests. Objective In this pilot project, we aimed to investigate the feasibility of using a mobile blood culture app to manage blood culture test quality. We implemented the app at a university hospital in South Korea to assess the potential for its utilization in a clinical environment by reviewing the usage data among a small group of users and by assessing their feedback and the data related to blood culture sampling. Methods We used an iOS-based blood culture app that uses an embedded camera to scan the patient identification and sample number bar codes. A total of 4 medical interns working at 2 medical intensive care units (MICUs) participated in this project, which spanned 3 weeks. App usage and blood culture sampling parameters (including sampler, sampling site, sampling time, and sample volume) were analyzed. The compliance of sampling parameter entry was also measured. In addition, the participants’ opinions regarding patient safety, timeliness, efficiency, and usability were recorded. Results In total, 356/644 (55.3%) of all blood culture samples obtained at the MICUs were examined using the app, including 254/356 (71.3%) with blood collection volumes of 5-7 mL and 256/356 (71.9%) with blood collection from the peripheral veins. The sampling volume differed among the participants. Sampling parameters were completely entered in 354/356 cases (99.4%). All the participants agreed that the app ensured good patient safety, disagreed on its

  14. Blood Culture Testing via a Mobile App That Uses a Mobile Phone Camera: A Feasibility Study.

    PubMed

    Lee, Guna; Lee, Yura; Chong, Yong Pil; Jang, Seongsoo; Kim, Mi Na; Kim, Jeong Hoon; Kim, Woo Sung; Lee, Jae-Ho

    2016-10-26

    To evaluate patients with fever of unknown origin or those with suspected bacteremia, the precision of blood culture tests is critical. An inappropriate step in the test process or error in a parameter could lead to a false-positive result, which could then affect the direction of treatment in critical conditions. Mobile health apps can be used to resolve problems with blood culture tests, and such apps can hence ensure that point-of-care guidelines are followed and processes are monitored for blood culture tests. In this pilot project, we aimed to investigate the feasibility of using a mobile blood culture app to manage blood culture test quality. We implemented the app at a university hospital in South Korea to assess the potential for its utilization in a clinical environment by reviewing the usage data among a small group of users and by assessing their feedback and the data related to blood culture sampling. We used an iOS-based blood culture app that uses an embedded camera to scan the patient identification and sample number bar codes. A total of 4 medical interns working at 2 medical intensive care units (MICUs) participated in this project, which spanned 3 weeks. App usage and blood culture sampling parameters (including sampler, sampling site, sampling time, and sample volume) were analyzed. The compliance of sampling parameter entry was also measured. In addition, the participants' opinions regarding patient safety, timeliness, efficiency, and usability were recorded. In total, 356/644 (55.3%) of all blood culture samples obtained at the MICUs were examined using the app, including 254/356 (71.3%) with blood collection volumes of 5-7 mL and 256/356 (71.9%) with blood collection from the peripheral veins. The sampling volume differed among the participants. Sampling parameters were completely entered in 354/356 cases (99.4%). All the participants agreed that the app ensured good patient safety, disagreed on its timeliness, and did not believe that it was

  15. Comparison of four methods for rapid identification of Staphylococcus aureus directly from BACTEC 9240 blood culture system.

    PubMed

    Ozen, N S; Ogunc, D; Mutlu, D; Ongut, G; Baysan, B O; Gunseren, F

    2011-01-01

    Differentiation of Staphylococcus aureus (S. aureus) from coagulase-negative staphylococci is very important in blood stream infections. Identification of S. aureus and coagulase-negative staphylococci (CoNS) from blood cultures takes generally 18-24 h after positive signaling on continuously monitored automated blood culture system. In this study, we evaluated the performance of tube coagulase test (TCT), slide agglutination test (Dry Spot Staphytect Plus), conventional polymerase chain reaction (PCR) and LightCycler Staphylococcus MGrade kit directly from blood culture bottles to achieve rapid identification of S. aureus by using the BACTEC 9240 blood culture system. A total of 129 BACTEC 9240 bottles growing gram-positive cocci suggesting Staphylococci were tested directly from blood culture broths (BCBs) with TCT, Dry Spot Staphytect Plus, conventional PCR and LightCycler Staphylococcus MGrade kit for rapid identification of S. aureus. The sensitivities of the tests were 99, 68, 99 and 100%, respectively. Our results suggested that 2 h TCT was found to be simple and inexpensive method for the rapid identification of S. aureus directly from positive blood cultures.

  16. The preanalytical optimization of blood cultures: a review and the clinical importance of benchmarking in 5 Belgian hospitals.

    PubMed

    Willems, Elise; Smismans, Annick; Cartuyvels, Reinoud; Coppens, Guy; Van Vaerenbergh, Kristien; Van den Abeele, Anne-Marie; Frans, Johan

    2012-05-01

    Bloodstream infections remain a major challenge in medicine. Optimal detection of pathogens is only possible if the quality of preanalytical factors is thoroughly controlled. Since the laboratory is responsible for this preanalytical phase, the quality control of critical factors should be integrated in its quality control program. The numerous recommendations regarding blood culture collection contain controversies. Only an unambiguous guideline permits standardization and interlaboratory quality control. We present an evidence-based concise guideline of critical preanalytical determinants for blood culture collection and summarize key performance indicators with their concomitant target values. In an attempt to benchmark, we compared the true-positive rate, contamination rate, and collected blood volume of blood culture bottles in 5 Belgian hospital laboratories. The true-positive blood culture rate fell within previously defined acceptation criteria by Baron et al. (2005) in all 5 hospitals, whereas the contamination rate exceeded the target value in 4 locations. Most unexpected, in each of the 5 laboratories, more than one third of the blood culture bottles were incorrectly filled, irrespective of the manufacturer of the blood culture vials. As a consequence of this shortcoming, one manufacturer recently developed an automatic blood volume monitoring system. In conclusion, clear recommendations for standardized blood culture collection combined with quality control of critical factors of the preanalytical phase are essential for diagnostic blood culture improvement. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. Large-scale clinical comparison of the lysis-centrifugation and radiometric systems for blood culture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brannon, P.; Kiehn, T.E.

    1985-12-01

    The Isolator 10 lysis-centrifugation blood culture system (E. I. du Pont de Nemours and Co., Inc., Wilmington, Del.) was compared with the BACTEC radiometric method (Johnston Laboratories, Inc., Towson, Md.) with 6B and 7D broth media for the recovery of bacteria and yeasts. From 11,000 blood cultures, 1,174 clinically significant organisms were isolated. The Isolator system recovered significantly more total organisms, members of the family Enterobacteriaceae, Staphylococcus spp., and yeasts. The BACTEC system recovered significantly more Pseudomonas spp., Streptococcus spp., and anaerobes. Of the Isolator colony counts, 87% measured less than 11 CFU/ml of blood. Organisms, on an average, weremore » detected the same day from each of the two culture systems. Only 13 of the 975 BACTEC isolates (0.01%) were recovered by subculture of growth-index-negative bottles, and 12 of the 13 were detected in another broth blood culture taken within 24 h. Contaminants were recovered from 4.8% of the Isolator 10 and 2.3% of the BACTEC cultures.« less

  18. Decreased mortality associated with prompt Gram staining of blood cultures.

    PubMed

    Barenfanger, Joan; Graham, Donald R; Kolluri, Lavanya; Sangwan, Gaurav; Lawhorn, Jerry; Drake, Cheryl A; Verhulst, Steven J; Peterson, Ryan; Moja, Lauren B; Ertmoed, Matthew M; Moja, Ashley B; Shevlin, Douglas W; Vautrain, Robert; Callahan, Charles D

    2008-12-01

    Gram stains of positive blood cultures are the most important factor influencing appropriate therapy. The sooner appropriate therapy is initiated, the better. Therefore, it is reasonable to expect that the sooner Gram stains are performed, the better. To determine the value of timely Gram stains and whether improvement in Gram stain turnaround time (TAT) is feasible, we compared data for matched pairs of patients with cultures processed promptly (<1 hour TAT) with data for patients with cultures not processed promptly (> or =1 hour TAT) and then monitored TAT by control charting.In 99 matched pairs, average difference in time to detection of positive blood cultures within a pair of patients was less than 0.1 hour. For the less than 1 hour TAT group, the average TAT and crude mortality were 0.1 hour and 10.1%, respectively; for the 1 hour or longer TAT group, they were 3.3 hours and 19.2%, respectively (P < .0001 and P = .0389, respectively). After multifaceted efforts, we achieved significant improvement in the TAT for Gram stains.

  19. Comparison of methods for identifying causative bacterial microorganisms in presumed acute endophthalmitis: conventional culture, blood culture, and PCR.

    PubMed

    Pongsachareonnont, Pear; Honglertnapakul, Worawalun; Chatsuwan, Tanittha

    2017-02-21

    Identification of bacterial pathogens in endophthalmitis is important to inform antibiotic selection and treatment decisions. Hemoculture bottles and polymerase chain reaction (PCR) analysis have been proposed to offer good detection sensitivity. This study compared the sensitivity and accuracy of a blood culture system, a PCR approach, and conventional culture methods for identification of causative bacteria in cases of acute endophthalmitis. Twenty-nine patients with a diagnosis of presumed acute bacterial endophthalmitis who underwent vitreous specimen collection at King Chulalongkorn Memorial Hospital were enrolled in this study. Forty-one specimens were collected. Each specimen was divided into three parts, and each part was analyzed using one of three microbial identification techniques: conventional plate culture, blood culture, and polymerase chain reaction and sequencing. The results of the three methods were then compared. Bacteria were identified in 15 of the 41 specimens (36.5%). Five (12.2%) specimens were positive by conventional culture methods, 11 (26.8%) were positive by hemoculture, and 11 (26.8%) were positive by PCR. Cohen's kappa analysis revealed p-values for conventional methods vs. hemoculture, conventional methods vs. PCR, and hemoculture vs. PCR of 0.057, 0.33, and 0.009, respectively. Higher detection rates of Enterococcus faecalis were observed for hemoculture and PCR than for conventional methods. Blood culture bottles and PCR detection may facilitate bacterial identification in cases of presumed acute endophthalmitis. These techniques should be used in addition to conventional plate culture methods because they provide a greater degree of sensitivity than conventional plate culture alone for the detection of specific microorganisms such as E. faecalis. Thai Clinical Trial Register No. TCTR20110000024 .

  20. Clinical significance of repeat blood cultures during febrile neutropenia in adult acute myeloid leukaemia patients undergoing intensive chemotherapy.

    PubMed

    Kimura, Shun-Ichi; Gomyo, Ayumi; Hayakawa, Jin; Tamaki, Masaharu; Akahoshi, Yu; Harada, Naonori; Ugai, Tomotaka; Kusuda, Machiko; Kameda, Kazuaki; Wada, Hidenori; Ishihara, Yuko; Kawamura, Koji; Sakamoto, Kana; Sato, Miki; Terasako-Saito, Kiriko; Kikuchi, Misato; Nakasone, Hideki; Kako, Shinichi; Tanihara, Aki; Kanda, Yoshinobu

    2017-10-01

    We evaluated the clinical significance of repeat blood cultures in persistent and recurrent fever during neutropenia in adult acute myeloid leukaemia (AML) and myelodysplastic syndrome (MDS) patients undergoing intensive chemotherapy. We retrospectively reviewed the chemotherapy cycles at our centre between January 2007 and December 2015. Blood cultures obtained within three days after initial febrile neutropenia (FN) were defined as initial blood cultures and those obtained on or after day 4 were defined as repeat blood cultures. Overall, 321 chemotherapy cycles in 89 patients were subjected to review. FN was identified in 276 (86.0%) chemotherapy cycles. In persistent FN (134 episodes), the causative pathogens were detected by repeat blood cultures in seven episodes (5.2%), including only three episodes (2.2%) of new infection. Shaking chills and high body temperature were identified as significant predictors for bloodstream infection (BSI). In recurrent FN (85 episodes), the causative pathogens were detected in seven episodes (8.2%), and all of these were new organisms. The frequency of detecting new pathogens by repeat blood cultures in recurrent FN (7/85) was higher than that in persistent FN (3/134) (p = .0491). A history of recent BSI was identified as a significant predictor for BSI in recurrent FN. The diagnostic yield of repeat blood cultures for persistent FN was low in intensive chemotherapy for AML and MDS. The frequency of repeat blood cultures for persistent FN could be reduced based on predictors. On the other hand, blood cultures were considered to be essential in cases with recurrent FN.

  1. Blood Cultures Drawn From Arterial Catheters Are Reliable for the Detection of Bloodstream Infection in Critically Ill Children.

    PubMed

    Berger, Itay; Gil Margolis, Merav; Nahum, Elhanan; Dagan, Ovdi; Levy, Itzhak; Kaplan, Eytan; Shostak, Eran; Shmuelov, Esther; Schiller, Ofer; Kadmon, Gili

    2018-05-01

    Arterial catheters may serve as an additional source for blood cultures in children when peripheral venipuncture is challenging. The aim of the study was to evaluate the accuracy of cultures obtained through indwelling arterial catheters for the diagnosis of bloodstream infections in critically ill pediatric patients. Observational and comparative. General and cardiac ICUs of a tertiary, university-affiliated pediatric medical center. The study group consisted of 138 patients admitted to the general or cardiac PICU in 2014-2015 who met the following criteria: presence of an indwelling arterial catheter and indication for blood culture. Blood was drawn by peripheral venipuncture and through the arterial catheter for each patient and sent for culture (total 276 culture pairs). Two specialists blinded to the blood source evaluated each positive culture to determine if the result represented true bloodstream infection or contamination. The sensitivity, specificity, and positive and negative predictive values of the arterial catheter and peripheral cultures for the diagnosis of bloodstream infection were calculated. Of the 56 positive cultures, 41 (15% of total samples) were considered diagnostic of true bloodstream infection. In the other 15 (5%), the results were attributed to contamination. The rate of false-positive results was higher for arterial catheter than for peripheral venipuncture cultures (4% vs 1.5%) but did not lead to prolonged unnecessary antibiotic treatment. On statistical analysis, arterial catheter blood cultures had high sensitivity (85%) and specificity (95%) for the diagnosis of true bloodstream infection, with comparable performance to peripheral blood cultures. Cultures of arterial catheter-drawn blood are reliable for the detection of bloodstream infection in PICUs.

  2. Kinetics of Poliovirus Shedding following Oral Vaccination as Measured by Quantitative Reverse Transcription-PCR versus Culture

    PubMed Central

    Begum, Sharmin; Uddin, Md Jashim; Platts-Mills, James A.; Liu, Jie; Kirkpatrick, Beth D.; Chowdhury, Anwarul H.; Jamil, Khondoker M.; Haque, Rashidul; Petri, William A.; Houpt, Eric R.

    2014-01-01

    Amid polio eradication efforts, detection of oral polio vaccine (OPV) virus in stool samples can provide information about rates of mucosal immunity and allow estimation of the poliovirus reservoir. We developed a multiplex one-step quantitative reverse transcription-PCR (qRT-PCR) assay for detection of OPV Sabin strains 1, 2, and 3 directly in stool samples with an external control to normalize samples for viral quantity and compared its performance with that of viral culture. We applied the assay to samples from infants in Dhaka, Bangladesh, after the administration of trivalent OPV (tOPV) at weeks 14 and 52 of life (on days 0 [pre-OPV], +4, +11, +18, and +25 relative to vaccination). When 1,350 stool samples were tested, the sensitivity and specificity of the quantitative PCR (qPCR) assay were 89 and 91% compared with culture. A quantitative relationship between culture+/qPCR+ and culture−/qPCR+ stool samples was observed. The kinetics of shedding revealed by qPCR and culture were similar. qPCR quantitative cutoffs based on the day +11 or +18 stool samples could be used to identify the culture-positive shedders, as well as the long-duration or high-frequency shedders. Interestingly, qPCR revealed that a small minority (7%) of infants contributed the vast majority (93 to 100%) of the total estimated viral excretion across all subtypes at each time point. This qPCR assay for OPV can simply and quantitatively detect all three Sabin strains directly in stool samples to approximate shedding both qualitatively and quantitatively. PMID:25378579

  3. Evaluation of negative results of BacT/Alert 3D automated blood culture system.

    PubMed

    Kocoglu, M Esra; Bayram, Aysen; Balci, Iclal

    2005-06-01

    Although automated continuous-monitoring blood culture systems are both rapid and sensitive, false-positive and false-negative results still occur. The objective of this study, then, was to evaluate negative results occurring with BacT/Alert 3D blood culture systems. A total of 1032 samples were cultured with the BacT/Alert 3D automated blood culture system, using both aerobic (FA) and anaerobic (FN) [corrected] media, and 128 of these samples yielded positive results. A total of 904 negative blood samples were then subcultured in 5% sheep blood agar, eosin methylene blue, chocolate agar, and sabouraud-dextrose agar. Organisms growing on these subcultures were subsequently identified using both Vitek32 (bioMerieux, Durham, NC) and conventional methods. Twenty four (2.6%) of the 904 subcultures grew on the subculture media. The majority (83.3%) of these were determined to be gram-positive microorganisms. Fourteen (58.3%) were coagulase-negative staphylococci, two (8.3%) were Bacillus spp., one (4.2%) was Staphylococcus aureus, and one (4.2%) was identified as Enterococcus faecium. Streptococcus pneumoniae and Neisseria spp. were isolated together in two (8.3%) vials. Gram-negative microorganisms comprised 12.5% of the subcultures, of which two (8.3%) were found to be Pseudomonas aeruginosa, and one (4.2%) was Pseudomonas fluorescens. The other isolate (4.2%) was identified as Candida albicans. We conclude that the subculture of negative results is valuable in the BacT/Alert 3D system, especially in situations in which only one set of blood cultures is taken.

  4. Performance Evaluation of the Verigene Gram-Positive and Gram-Negative Blood Culture Test for Direct Identification of Bacteria and Their Resistance Determinants from Positive Blood Cultures in Hong Kong

    PubMed Central

    Siu, Gilman K. H.; Chen, Jonathan H. K.; Ng, T. K.; Lee, Rodney A.; Fung, Kitty S. C.; To, Sabrina W. C.; Wong, Barry K. C.; Cheung, Sherman; Wong, Ivan W. F.; Tam, Marble M. P.; Lee, Swing S. W.; Yam, W. C.

    2015-01-01

    Background A multicenter study was conducted to evaluate the diagnostic performance and the time to identifcation of the Verigene Blood Culture Test, the BC-GP and BC-GN assays, to identify both Gram-positive and Gram-negative bacteria and their drug resistance determinants directly from positive blood cultures collected in Hong Kong. Methods and Results A total of 364 blood cultures were prospectively collected from four public hospitals, in which 114 and 250 cultures yielded Gram-positive and Gram-negative bacteria, and were tested with the BC-GP and BC-GN assay respectively. The overall identification agreement for Gram-positive and Gram-negative bacteria were 89.6% and 90.5% in monomicrobial cultures and 62.5% and 53.6% in polymicrobial cultures, respectively. The sensitivities for most genus/species achieved at least 80% except Enterococcus spp. (60%), K.oxytoca (0%), K.pneumoniae (69.2%), whereas the specificities for all targets ranged from 98.9% to 100%. Of note, 50% (7/14) cultures containing K.pneumoniae that were missed by the BC-GN assay were subsequently identified as K.variicola. Approximately 5.5% (20/364) cultures contained non-target organisms, of which Aeromonas spp. accounted for 25% and are of particular concern. For drug resistance determination, the Verigene test showed 100% sensitivity for identification of MRSA, VRE and carbapenem resistant Acinetobacter, and 84.4% for ESBL-producing Enterobacteriaceae based on the positive detection of mecA, vanA, bla OXA and bla CTXM respectively. Conclusion Overall, the Verigene test provided acceptable accuracy for identification of bacteria and resistance markers with a range of turnaround time 40.5 to 99.2 h faster than conventional methods in our region. PMID:26431434

  5. A Retrospective Evaluation of Critical Care Blood Culture Yield - Do Support Services Contribute to the "Weekend Effect"?

    PubMed

    Morton, Ben; Nagaraja, Shankara; Collins, Andrea; Pennington, Shaun H; Blakey, John D

    2015-01-01

    The "weekend effect" describes an increase in adverse outcomes for patients admitted at the weekend. Critical care units have moved to higher intensity working patterns to address this with some improved outcomes. However, support services have persisted with traditional working patterns. Blood cultures are an essential diagnostic tool for patients with sepsis but yield is dependent on sampling technique and processing. We therefore used blood culture yield as a surrogate for the quality of support service provision. We hypothesized that blood culture yields would be lower over the weekend as a consequence of reduced support services. We performed a retrospective observational study examining 1575 blood culture samples in a university hospital critical care unit over a one-year period. Patients with positive cultures had, on average, higher APACHE II scores (p = 0.015), longer durations of stay (p = 0.03), required more renal replacement therapy (p<0.001) and had higher mortality (p = 0.024). Blood culture yield decreased with repeated sampling with an increased proportion of contaminants. Blood cultures were 26.7% less likely to be positive if taken at the weekend (p = 0.0402). This effect size is the equivalent to the impact of sampling before and after antibiotic administration. Our study demonstrates that blood culture yield is lower at the weekend. This is likely caused by delays or errors in incubation and processing, reflecting the reduced provision of support services at the weekend. Reorganization of services to address the "weekend effect" should acknowledge the interdependent nature of healthcare service delivery.

  6. Blood color is influenced by inflammation and independently predicts survival in hemodialysis patients: quantitative evaluation of blood color.

    PubMed

    Shibata, Masanori; Nagai, Kojiro; Doi, Toshio; Tawada, Hideo; Taniguchi, Shinkichi

    2012-11-01

    Blood color of dialysis patients can be seen routinely. Darkened blood color is often observed in critically ill patients generally because of decreased oxygen saturation, but little is known about the other factors responsible for the color intensity. In addition, quantitative blood color examination has not been performed yet. Therefore, no one has evaluated the predictive power of blood color. The aim of this study was to evaluate if blood color darkness reflects some medical problems and is associated with survival disadvantage. Study design is a prospective cohort study. One hundred sixty-seven patients were enrolled in this study. Quantification of blood color was done using a reflected light colorimeter. Demographic and clinical data were collected to find out the factors that can be related to blood color. Follow-ups were performed for 2 years to analyze the risk factors for their survival. Regression analysis showed that C-reactive protein and white blood cell count were negatively correlated with blood color. In addition, blood color was positively correlated with mean corpuscular hemoglobin concentration and serum sodium concentration as well as blood oxygen saturation. During a follow-up, 34 (20.4%) patients died. Cox regression analysis revealed that darkened blood color was an independent significant risk factor of mortality in hemodialysis patients as well as low albumin and low Kt/V. These results suggest that inflammation independently affects blood color and quantification of blood color is useful to estimate prognosis in patients undergoing hemodialysis. It is possible that early detection of blood color worsening can improve patients' survival. © 2012, Copyright the Authors. Artificial Organs © 2012, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  7. Diet and Blood Pressure Control in Chinese Canadians: Cultural Considerations.

    PubMed

    Zou, Ping

    2017-04-01

    Hypertension is highly prevalent in Chinese Canadians and diet has been identified as an important modifiable risk factor for hypertension. The current anti-hypertensive dietary recommendations in hypertension care guidelines lack examination of cultural factors, are not culturally sensitive to ethnic populations, and cannot be translated to Chinese Canadian populations without cultural considerations. Guided by Leininger's Sunrise Model of culture care theory, this paper investigates how cultural factors impact Chinese Canadians' dietary practice. It is proposed that English language proficiency, health literacy, traditional Chinese diet, migration and acculturation, and Traditional Chinese Medicine influence Chinese Canadians' dietary practices. A culturally congruent nursing intervention should be established and tailored according to related cultural factors to facilitate Chinese Canadians' blood pressure control. In addition, further study is needed to test the model adapted from Sunrise Model and understand its mechanism.

  8. Impact of antibiotic administration on blood culture positivity at the beginning of sepsis: a prospective clinical cohort study.

    PubMed

    Scheer, Christian S; Fuchs, Christian; Gründling, Matthias; Vollmer, Marcus; Bast, Juliane; Bohnert, Jürgen A; Zimmermann, Kathrin; Hahnenkamp, Klaus; Rehberg, Sebastian; Kuhn, Sven-Olaf

    2018-06-04

    Sepsis guidelines recommend obtaining blood cultures before starting anti-infective therapy in patients with sepsis. However, little is known how antibiotic treatment prior to sampling affects bacterial growth. The aim of this study was to compare the results of blood cultures drawn prior to and under antibiotic therapy. Prospective clinical cohort study of septic patients. Adult ICU patients with 2 or 3 blood culture (BC) sets at the beginning of sepsis between 2010 and 2017 were included. Patients with blood culture samplings obtained prior to antibiotic therapy were compared to patients with samplings under antibiotic therapy. Blood culture positivity, defined as microbiological pathogen finding, was compared between the groups. Logistic regression was performed to adjust the impact of different factors with respect to blood culture positivity. In total, 559 patients with 1364 blood culture sets at the beginning of sepsis were analyzed. BC positivity was 50.6% (78/154) among septic patients who did not receive antibiotics and only 27.7% (112/405) in those who were already under antibiotics (P<0.001). Logistic regression revealed antibiotic therapy as an independent factor for less pathogen identification (Odds ratio 0.4; 95%CI 0.3-0.6). Gram-positive pathogens (28.3%(111/392) vs. 11.9%(116/972);P<0.001) and also gram-negative pathogens (16.3%(64/392) vs. 9.3%(90/972);P<0.001) were more frequent in BC sets drawn prior to antibiotic therapy compared to sets under antibiotics. Obtaining blood cultures under antibiotic therapy is associated with a significant loss of pathogen detection. This strongly emphasizes the current recommendation to obtain blood cultures prior to antibiotic administration in patients with sepsis. Copyright © 2018. Published by Elsevier Ltd.

  9. Prospective identification of erythroid elements in cultured peripheral blood.

    PubMed

    Miller, J L; Njoroge, J M; Gubin, A N; Rodgers, G P

    1999-04-01

    We have developed a prospective approach to identify the generation of erythroid cells derived from cultured peripheral blood mononuclear cells (PBMC) by monitoring the expression of the cell surface protein CD48. Unpurified populations of PBMC obtained from the buffy coats of normal volunteers were grown in suspension culture in the absence or presence of erythropoietin. A profile of surface CD48 expression permitted a flow cytometric identification of erythropoietin responsive populations at various stages of their maturation. In the absence of erythropoietin (EPO) supplemented media, the CD48- cells represented <5% of the total population of PBMC remaining in culture. In cultures supplemented with 1 U/mL EPO, the mean percentage of CD48- cells increased to 34.7 + 14.9% (p < 0.01) after 14 days in culture. Coordinated CD34 and CD71 (transferrin receptor) expression, morphology, gamma-globin transcription, and colony formation in methylcellulose were observed during the 14-day culture period. Flow cytometric monitoring of bulk cultured PBMC provides a simple and reliable means for the prospective or real-time study of human erythropoiesis.

  10. Microbiology of liver abscesses and the predictive value of abscess gram stain and associated blood cultures.

    PubMed

    Chemaly, Roy F; Hall, Gerri S; Keys, Thomas F; Procop, Gary W

    2003-08-01

    Although rare, pyogenic liver abscesses are potentially fatal. We evaluated the predictive value of Gram stain of liver abscess aspirates and temporally associated blood cultures. Gram stains detected bacteria in 79% of the liver abscesses tested. The sensitivity and specificity of Gram stain of the liver abscesses were 90% and 100% for Gram-positive cocci (GPC) and 52% and 94% for Gram-negative bacilli (GNB). The sensitivities of the blood cultures for any GPC and GNB present in the liver abscess were 30% and 39%, respectively. Although, Gram stains and blood cultures offer incomplete detection of the microbial contents of pyogenic liver abscesses, both tests should always accompany liver abscess cultures.

  11. Educational intervention as an effective step for reducing blood culture contamination: a prospective cohort study.

    PubMed

    Park, W B; Myung, S J; Oh, M-d; Lee, J; Kim, N-J; Kim, E-C; Park, J S

    2015-10-01

    Contaminated blood cultures lead to diagnostic challenges and place a burden on healthcare services. To determine the impact of introducing a clinical skills test (CST) as part of the medical licensing examination and an institutional education programme on the contamination rates of blood cultures. A prospective cohort study was conducted from 2009 through 2013 in all wards of a tertiary-care teaching hospital. We evaluated the effects of the CST, which was added to the National Medical Licensing Examination in Korea (KMLE) in 2010 and our institutional education programme, which began in 2013. The medical interns in charge of collection of blood for culture were divided in three groups with presence or absence of CST and the institutional education programme. The primary outcome was the percentage of blood cultures contaminated in each group, which were compared using the Poisson regression model. Participants' self-rated scores for the blood draw procedure were also analysed. Although introduction of the CST in the KMLE failed to reduce blood culture contamination rate (1.36% vs 1.35%; P = 0.734), the institutional education programme significantly reduced the contamination rate (1.35% vs 1.00%; P < 0.0001). Most participants answered that they always followed each step correctly except for waiting the recommended contact time after applying the antiseptic. The educational intervention, not the introduction of CST in the KMLE, was effective in reducing overall contamination rates. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  12. Quantitative phase imaging characterization of tumor-associated blood vessel formation on a chip

    NASA Astrophysics Data System (ADS)

    Guo, Peng; Huang, Jing; Moses, Marsha A.

    2018-02-01

    Angiogenesis, the formation of new blood vessels from existing ones, is a biological process that has an essential role in solid tumor growth, development, and progression. Recent advances in Lab-on-a-Chip technology has created an opportunity for scientists to observe endothelial cell (EC) behaviors during the dynamic process of angiogenesis using a simple and economical in vitro platform that recapitulates in vivo blood vessel formation. Here, we use quantitative phase imaging (QPI) microscopy to continuously and non-invasively characterize the dynamic process of tumor cell-induced angiogenic sprout formation on a microfluidic chip. The live tumor cell-induced angiogenic sprouts are generated by multicellular endothelial sprouting into 3 dimensional (3D) Matrigel using human umbilical vein endothelial cells (HUVECs). By using QPI, we quantitatively measure a panel of cellular morphological and behavioral parameters of each individual EC participating in this sprouting. In this proof-of-principle study, we demonstrate that QPI is a powerful tool that can provide real-time quantitative analysis of biological processes in in vitro 3D biomimetic devices, which, in turn, can improve our understanding of the biology underlying functional tissue engineering.

  13. Towards cultural materialism in the medical humanities: the case of blood rejuvenation

    PubMed Central

    2018-01-01

    This paper argues for an approach within the medical humanities that draws on the theoretical legacy of cultural materialism as a framework for reading cultural practices and their relationship to the social and economic order. It revisits the origins and development of cultural materialism in cultural studies and literary studies between the 1970s and 1990s and considers how, with adaptation, this methodology might facilitate ideological criticism focused on material formations of health, disease and the human body. I outline three key characteristics of a medicocultural materialist approach along these lines: (a) interdisciplinary work on a broad range of medical and cultural sources, including those drawn from ‘popular’ forms of culture; (b) the combination of historicist analysis with scrutiny of present-day contexts; (c) analyses that engage with political economy perspectives and/or the work of medical sociology in this area. The subsequent sections of the paper employ a medicocultural materialist approach to examine conjectural understandings of, and empirical investigations into, the capacity of transfused human blood to rejuvenate the ageing body. I trace textual faultlines that expose the structures of power which inform the movement of blood between bodies in ‘medical gothic’ fictions from the 19th-century fin de siècle, including Mary Elizabeth Braddon's ‘Good Lady Ducayne’ (1896) and Bram Stoker's Dracula (1897). I conclude with a critique of biomedical innovations in blood rejuvenation in the era of medical neoliberalism, before considering the potential applications of medicocultural materialism to other topics within the field of the medical humanities. PMID:28495908

  14. A randomized trial of povidone-iodine compared with iodine tincture for venipuncture site disinfection: effects on rates of blood culture contamination.

    PubMed

    Little, J R; Murray, P R; Traynor, P S; Spitznagel, E

    1999-08-01

    Contamination of blood cultures creates problems in their interpretation and unneeded resource utilization. Because skin flora comprise the major group of contaminant species, more effective skin disinfection at the venipuncture site could reduce contamination. We performed a randomized trial in adult inpatients at a tertiary care teaching hospital. Antecubital venipuncture sites were randomly disinfected with povidone-iodine or iodine tincture, and blood cultures (two bottles, 10 mL of blood) were drawn by professional phlebotomists. Scoring of contaminant species was restricted to skin flora. Hospital resource utilization was compared among patients with contaminated blood cultures and those with sterile blood cultures. Of the 3,851 blood cultures collected during the study, 120 (3.1%) were contaminated with skin flora. The contamination rate for blood cultures collected after povidone-iodine was 3.8% (74 of 1,947), compared with a rate of 2.4% (46 of 1,904, P = 0.01) after iodine tincture. The difference in mean total hospital costs for patients with contaminated blood cultures and those with sterile blood cultures was $4,100 (95% confidence interval: $740 to $7,400, P = 0.02). Iodine tincture is superior to povidone-iodine for venipuncture site antisepsis before blood culture sampling. Because of the high costs associated with contaminated blood cultures, hospitals should consider switching from povidone-iodine to iodine tincture. Reduction of the contamination rate may improve the quality of patient care and reduce hospital costs.

  15. The Clinical Impact of Rapid, Direct MALDI-ToF Identification of Bacteria from Positive Blood Cultures.

    PubMed

    French, Kathryn; Evans, Jason; Tanner, Hannah; Gossain, Savita; Hussain, Abid

    2016-01-01

    Faster identification of bacterial isolates from blood cultures can enable earlier clinical intervention for patients with sepsis. We evaluated the clinical impact of direct identification of micro-organisms from positive blood cultures using MALDI-ToF. Positive blood cultures with organisms seen on Gram stain were included over a four week period. For each patient case, comparison was made between the clinical advice given on day one with only a Gram stain result, and the follow up advice given on day two with the benefit of organism identification. Culture results were then compared with direct MALDI-ToF identification. For 73 of 115 cases (63.5%), direct organism identification was obtained by MALDI-ToF. Of those 73, 70 (95.5%) had a result concordant with that of the plate culture. In 28 of the 115 cases (24.3%) direct MALDI-ToF identification on day one would have had a clear clinical benefit. In 11 cases it would have helped to identify the potential source of bacteraemia. In 11 cases it would have indicated a different antibiotic regimen on day one, with five patients receiving appropriate antibiotics 24 hours earlier. For 14 cases the blood culture isolate could have been designated as unlikely to be clinically significant. We have demonstrated that organism identification on day one of blood culture positivity can have a direct clinical impact. Faster identification using MALDI-ToF assists the clinician in assessing the significance of a blood culture isolate on day one. It can allow earlier appropriate choice of antimicrobial agent, even in the absence of susceptibility testing, and help narrow down the potential source of infection providing a focus for further investigation in a more timely way than conventional techniques alone.

  16. Use of BBL CHROMagar MRSA Medium for Identification of Methicillin-Resistant Staphylococcus aureus Directly from Blood Cultures

    PubMed Central

    Pape, John; Wadlin, Jill; Nachamkin, Irving

    2006-01-01

    We evaluated the ability of BBL CHROMagar MRSA medium (Becton Dickinson, Sparks, MD) to identify methicillin-resistant Staphylococcus aureus (MRSA) directly upon subculture from positive blood culture bottles. There were 124 MRSA isolates recovered from blood cultures in the study. BBL CHROMagar MRSA medium was highly sensitive (97.6% [121/124] at 18 to 24 h of incubation and 100% [124/124] at 48 h) and 99.9% specific for identifying MRSA from positive blood cultures. PMID:16825383

  17. QUANTITATION OF MENSTRUAL BLOOD LOSS: A RADIOACTIVE METHOD UTILIZING A COUNTING DOME

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tauxe, W.N.

    A description has been given of a simple, accurate tech nique for the quantitation of menstrual blood loss, involving the determination of a three- dimensional isosensitivity curve and the fashioning of a lucite dome with cover to fit these specifications. Ten normal subjects lost no more than 50 ml each per menstrual period. (auth)

  18. Reducing time to identification of positive blood cultures with MALDI-TOF MS analysis after a 5-h subculture.

    PubMed

    Verroken, A; Defourny, L; Lechgar, L; Magnette, A; Delmée, M; Glupczynski, Y

    2015-02-01

    Speeding up the turn-around time of positive blood culture identifications is essential in order to optimize the treatment of septic patients. Several sample preparation techniques have been developed allowing direct matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) identification of positive blood cultures. Yet, the hands-on time restrains their routine workflow. In this study, we evaluated an approach whereby MALDI-TOF MS identification without any additional steps was carried out on short subcultured colonies from positive blood bottles with the objective of allowing results reporting on the day of positivity detection. Over a 7-month period in 2012, positive blood cultures detected by 9 am with an automated system were inoculated onto a Columbia blood agar and processed after a 5-h incubation on a MALDI-TOF MicroFlex platform (Bruker Daltonik GmbH). Single-spotted colonies were covered with 1 μl formic acid and 1 μl matrix solution. The results were compared to the validated identification techniques. A total of 925 positive blood culture bottles (representing 470 bacteremic episodes) were included. Concordant identification was obtained in 727 (81.1 %) of the 896 monomicrobial blood cultures, with failure being mostly observed with anaerobes and yeasts. In 17 episodes of polymicrobic bacteremia, the identification of one of the two isolates was achieved in 24/29 (82.7 %) positive cultures. Routine implementation of MALDI-TOF MS identification on young positive blood subcultures provides correct results to the clinician in more than 80 % of the bacteremic episodes and allows access to identification results on the day of blood culture positivity detection, potentially accelerating the implementation of targeted clinical treatments.

  19. Direct and quantitative analysis of underivatized acylcarnitines in serum and whole blood using paper spray mass spectrometry

    PubMed Central

    Yang, Qian; Manicke, Nicholas E.; Wang, He; Petucci, Christopher; Cooks, R. Graham

    2013-01-01

    A simple protocol for rapid quantitation of acylcarnitines in serum and whole blood has been developed using paper spray mass spectrometry. Dried serum and whole blood containing a mixture of ten acylcarnitines at various concentrations were analyzed as spots from paper directly without any sample pretreatment, separation, or derivatization. The composition of the spray solvent was found to be a critical factor: for serum samples, spray solvent of methanol/water/formic acid (80:20:0.1) gave the best signal intensity while for blood samples which contain more matrix components, acetonitrile/water (90:10) was a much more suitable spray solvent. For the paper type and size used, 0.5 μL of sample provided an optimal signal for both serum and whole blood samples. For quantitative profiling, the limits of quantitation obtained from both serum and blood were much lower than the clinically validated cutoff values for diagnosis of fatty acid oxidation disorders in newborn screening. Linearity (R2>0.95) and reproducibility (RSD ~10 %) were achieved in the concentration ranges from 100 nM to 5 μM for the C2 acylcarnitine, and for other acylcarnitines, these values were from 10 to 500 nM. Acylcarnitine profiles offer an effective demonstration of the fact that paper spray mass spectrometry is an appropriate, simple, rapid method with high sensitivity and high reproducibility applicable to newborn screening tests. PMID:22760507

  20. Blood culture-PCR to optimise typhoid fever diagnosis after controlled human infection identifies frequent asymptomatic cases and evidence of primary bacteraemia.

    PubMed

    Darton, Thomas C; Zhou, Liqing; Blohmke, Christoph J; Jones, Claire; Waddington, Claire S; Baker, Stephen; Pollard, Andrew J

    2017-04-01

    Improved diagnostics for typhoid are needed; a typhoid controlled human infection model may accelerate their development and translation. Here, we evaluated a blood culture-PCR assay for detecting infection after controlled human infection with S. Typhi and compared test performance with optimally performed blood cultures. Culture-PCR amplification of blood samples was performed alongside daily blood culture in 41 participants undergoing typhoid challenge. Study endpoints for typhoid diagnosis (TD) were fever and/or bacteraemia. Overall, 24/41 (59%) participants reached TD, of whom 21/24 (86%) had ≥1 positive blood culture (53/674, 7.9% of all cultures) or 18/24 (75%) had ≥1 positive culture-PCR assay result (57/684, 8.3%). A further five non-bacteraemic participants produced culture-PCR amplicons indicating infection; overall sensitivity/specificity of the assay compared to the study endpoints were 70%/65%. We found no significant difference between blood culture and culture-PCR methods in ability to identify cases (12 mismatching pairs, p = 0.77, binomial test). Clinical and stool culture metadata demonstrated that additional culture-PCR amplification positive individuals likely represented true cases missed by blood culture, suggesting the overall attack rate may be 30/41 (73%) rather than 24/41 (59%). Several participants had positive culture-PCR results soon after ingesting challenge providing new evidence for occurrence of an early primary bacteraemia. Overall the culture-PCR assay performed well, identifying extra typhoid cases compared with routine blood culture alone. Despite limitations to widespread field-use, the benefits of increased diagnostic yield, reduced blood volume and faster turn-around-time, suggest that this assay could enhance laboratory typhoid diagnostics in research applications and high-incidence settings. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  1. Quantitative versus qualitative cultures of respiratory secretions for clinical outcomes in patients with ventilator-associated pneumonia.

    PubMed

    Berton, Danilo Cortozi; Kalil, Andre C; Cavalcanti, Manuela; Teixeira, Paulo José Zimermann

    2008-10-08

    Ventilator-associated pneumonia (VAP) is a common infectious disease in intensive care units (ICUs). The best diagnostic approach to resolve this condition remains uncertain. To evaluate whether quantitative cultures of respiratory secretions are effective in reducing mortality in immunocompetent patients with VAP, compared with qualitative cultures. We also considered changes in antibiotic use, length of ICU stay and mechanical ventilation. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2007, issue 4), which contains the Acute Respiratory Infections Group's Specialized Register; MEDLINE (1966 to December 2007); EMBASE (1974 to December 2007); and LILACS (1982 to December 2007). Randomized controlled trials (RCTs) comparing respiratory samples processed quantitatively or qualitatively, obtained by invasive or non-invasive methods from immunocompetent patients with VAP, and which analyzed the impact of these methods on antibiotic use and mortality rates. Two review authors independently reviewed and selected trials from the search results, and assessed studies for suitability, methodology and quality. We analyzed data using Review Manager software. We pooled the included studies to yield the risk ratio (RR) for mortality and antibiotic change with 95% confidence intervals (CI). Of the 3931 references identified from the electronic databases, five RCTs (1367 patients) met the inclusion criteria. Three studies compared invasive methods using quantitative cultures versus non-invasive methods using qualitative cultures, and were used to answer the main objective of this review. The other two studies compared invasive versus non-invasive methods, both using quantitative cultures. All five studies were combined to compare invasive versus non-invasive interventions for diagnosing VAP. The studies that compared quantitative and qualitative cultures (1240 patients) showed no statistically significant differences in mortality

  2. Identification of blood culture isolates directly from positive blood cultures by use of matrix-assisted laser desorption ionization-time of flight mass spectrometry and a commercial extraction system: analysis of performance, cost, and turnaround time.

    PubMed

    Lagacé-Wiens, Philippe R S; Adam, Heather J; Karlowsky, James A; Nichol, Kimberly A; Pang, Paulette F; Guenther, Jodi; Webb, Amanda A; Miller, Crystal; Alfa, Michelle J

    2012-10-01

    Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry represents a revolution in the rapid identification of bacterial and fungal pathogens in the clinical microbiology laboratory. Recently, MALDI-TOF has been applied directly to positive blood culture bottles for the rapid identification of pathogens, leading to reductions in turnaround time and potentially beneficial patient impacts. The development of a commercially available extraction kit (Bruker Sepsityper) for use with the Bruker MALDI BioTyper has facilitated the processing required for identification of pathogens directly from positive from blood cultures. We report the results of an evaluation of the accuracy, cost, and turnaround time of this method for 61 positive monomicrobial and 2 polymicrobial cultures representing 26 species. The Bruker MALDI BioTyper with the Sepsityper gave a valid (score, >1.7) identification for 85.2% of positive blood cultures with no misidentifications. The mean reduction in turnaround time to identification was 34.3 h (P < 0.0001) in the ideal situation where MALDI-TOF was used for all blood cultures and 26.5 h in a more practical setting where conventional identification or identification from subcultures was required for isolates that could not be directly identified by MALDI-TOF. Implementation of a MALDI-TOF-based identification system for direct identification of pathogens from blood cultures is expected to be associated with a marginal increase in operating costs for most laboratories. However, the use of MALDI-TOF for direct identification is accurate and should result in reduced turnaround time to identification.

  3. Comparative usefulness of inflammatory markers to indicate bacterial infection-analyzed according to blood culture results and related clinical factors.

    PubMed

    Nishikawa, Hirokazu; Shirano, Michinori; Kasamatsu, Yu; Morimura, Ayumi; Iida, Ko; Kishi, Tomomi; Goto, Tetsushi; Okamoto, Saki; Ehara, Eiji

    2016-01-01

    To assess relationships of inflammatory markers and 2 related clinical factors with blood culture results, we retrospectively investigated inpatients' blood culture and blood chemistry findings that were recorded from January to December 2014 using electronic medical records and analyzed the data of 852 subjects (426 culture-positive and 426 culture-negative). Results suggested that the risk of positive blood culture statistically increased as inflammatory marker levels and the number of related factors increased. Concerning the effectiveness of inflammatory markers, when the outcome definition was also changed for C-reactive protein (CRP), the odds ratio had a similar value, whereas when the outcome definition of blood culture positivity was used for procalcitonin (PCT), the greatest effectiveness of that was detected. Therefore, the current results suggest that PCT is more useful than CRP as an auxiliary indication of bacterial infection. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Using electronic data to predict the probability of true bacteremia from positive blood cultures.

    PubMed

    Wang, S J; Kuperman, G J; Ohno-Machado, L; Onderdonk, A; Sandige, H; Bates, D W

    2000-01-01

    As part of a project to help physicians make more appropriate treatment decisions, we implemented a clinical prediction rule that computes the probability of true bacteremia for positive blood cultures and displays this information when culture results are viewed online. Prior to implementing the rule, we performed a revalidation study to verify the accuracy of the previously published logistic regression model. We randomly selected 114 cases of positive blood cultures from a recent one-year period and performed a paper chart review with the help of infectious disease experts to determine whether the cultures were true positives or contaminants. Based on the results of this revalidation study, we updated the probabilities reported by the model and made additional enhancements to improve the accuracy of the rule. Next, we implemented the rule into our hospital's laboratory computer system so that the probability information was displayed with all positive blood culture results. We displayed the prediction rule information on approximately half of the 2184 positive blood cultures at our hospital that were randomly selected during a 6-month period. During the study, we surveyed 54 housestaff to obtain their opinions about the usefulness of this intervention. Fifty percent (27/54) indicated that the information had influenced their belief of the probability of bacteremia in their patients, and in 28% (15/54) of cases it changed their treatment decision. Almost all (98% (53/54)) indicated that they wanted to continue receiving this information. We conclude that the probability information provided by this clinical prediction rule is considered useful to physicians when making treatment decisions.

  5. Comparative evaluation of two rapid Salmonella-IgM tests and blood culture in the diagnosis of enteric fever.

    PubMed

    Prasad, K J; Oberoi, J K; Goel, N; Wattal, C

    2015-01-01

    Enteric fever is a major public health problem in developing countries like India. An early and accurate diagnosis is necessary for a prompt and effective treatment. We have evaluated the diagnostic accuracy of two Rapid Salmonella-IgM tests (Typhidot-IgM and Enteroscreen-IgM) as compared to blood culture in rapid and early diagnosis of enteric fever. A total of 2,699 patients' serum samples were tested by Rapid Salmonella-IgM tests and blood culture. Patients were divided into two groups. Test group - patients with enteric fever and blood culture positives for Salmonella Typhi; and three types of Controls, i.e. patients with non-enteric fever illnesses, normal healthy controls and patients positive for S. Paratyphi- A. In addition to this we have also evaluated the significance of positive Salmonella-IgM tests among blood culture-negative cases. The overall sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the Typhidot-IgM test and Enteroscreen-IgM test considering blood culture as gold standard were 97.29% and 88.13%, 97.40% and 87.83%, 98.18% and 92.03%, 96.15% and 82.27%, respectively. Typhidot-IgM test was found to be significantly more sensitive and specific as compared to Enteroscreen-IgM. Among blood culture-negative patients, Rapid Salmonella-IgM tests detected 72.25% additional cases of enteric fever. Although the Rapid Salmonella-IgM tests are meant to diagnose S. Typhi only, but these tests detect S. Paratyphi- A also. Thirty-eight patients who were blood culture-positive for S. Paratyphi- A were also positive by Rapid Salmonella-IgM tests. Rapid Salmonella-IgM tests offer an advantage of increased sensitivity, rapidity, early diagnosis and simplicity over blood culture.

  6. Measurement of Blood Coagulation Factor Synthesis in Cultures of Human Hepatocytes.

    PubMed

    Heinz, Stefan; Braspenning, Joris

    2015-01-01

    An important function of the liver is the synthesis and secretion of blood coagulation factors. Within the liver, hepatocytes are involved in the synthesis of most blood coagulation factors, such as fibrinogen, prothrombin, factor V, VII, IX, X, XI, XII, as well as protein C and S, and antithrombin, whereas liver sinusoidal endothelial cells produce factor VIII and von Willebrand factor. Here, we describe methods for the detection and quantification of most blood coagulation factors in hepatocytes in vitro. Hepatocyte cultures indeed provide a valuable tool to study blood coagulation factors. In addition, the generation and expansion of hepatocytes or hepatocyte-like cells may be used in future for cell-based therapies of liver diseases, including blood coagulation factor deficiencies.

  7. Predicting bacteremia based on nurse-assessed food consumption at the time of blood culture.

    PubMed

    Komatsu, Takayuki; Onda, Toshihito; Murayama, Go; Yamanouchi, Masashi; Inukai, Minori; Sakai, Ai; Kikuta, Masumi; Branch, Joel; Aoki, Makoto; Tierney, Lawrence M; Inoue, Kenji

    2012-01-01

    Bacteremia and its complications are important causes of morbidity and mortality in hospitalized patients. However, the yield of blood cultures is relatively low, with many false-positive results from bacterial contamination. We investigated the relationship between patient food consumption and the presence of bacteremia. This was an observational analysis of a cohort of 1179 patients who underwent blood culture analysis between January 2005 and December 2009. Patients with anorexia-inducing conditions, such as gastrointestinal illness and malignant disease treated with chemotherapy, were excluded. Food consumption was rated by nurses as the percentage of food consumed during the meal preceding the blood culture. Groupings were as follows: low consumption (<50%), moderate (>50% to <80%), and high (>80%). Low consumption was observed in 39.8% of patients, moderate in 17.8%, and high in 41.6%. The average body temperature was 38.1 ± 1.1°C. Bacteremia was present in 18.5%, 3.9%, and 1.4% of patients in the low, moderate, and high food consumption groups, respectively. The negative predictive value was 98.3%, suggesting that bacteremia is very unlikely in the setting of good food intake. Bacteremia is an unlikely occurrence in hospitalized patients who maintain adequate food consumption at the time of blood culture. Copyright © 2012 Society of Hospital Medicine.

  8. Intestinal blood loss during cow milk feeding in older infants: quantitative measurements.

    PubMed

    Jiang, T; Jeter, J M; Nelson, S E; Ziegler, E E

    2000-07-01

    To determine the response, in terms of fecal hemoglobin excretion and clinical symptoms, of normal 9 1/2-month-old infants to being fed cow milk. Longitudinal (before-after) trial in which each infant was fed formula for 1 month (baseline) followed by 3 months during which cow milk was fed. Healthy infants living in Iowa City, Iowa, a town with a population of about 60,000. Hemoglobin concentration in spot stools, 96-hour quantitative fecal hemoglobin excretion, stool characteristics, feeding-related behaviors, and iron nutritional status. Fecal hemoglobin concentration during formula feeding (baseline) was higher than previously observed in younger infants. Nine of 31 infants responded to cow milk feeding with increased fecal hemoglobin concentration. Fecal hemoglobin concentration (mean +/- SD) of the 9 responders rose from 1,395 +/- 856 microg/g of dry stool (baseline) to 2,711 +/- 1,732 microg/g of dry stool (P=.01). The response rate (29%) was similar to that in younger infants, but the intensity of the response was much less. Quantitative hemoglobin excretion was in general agreement with estimates based on spot stool hemoglobin concentrations. Cow milk feeding was not associated with recognizable changes in stool characteristics, nor were there clinical signs related to fecal blood loss. Iron status was similar, except that after 3 months of cow milk feeding responders showed lower (P= .047) ferritin concentrations than nonresponders. Cow milk-induced blood loss is present in 9 1/2-month-old infants but is of such low intensity that its clinical significance seems questionable. Nevertheless, infants without cow milk-induced blood loss were in better iron nutritional status than infants who showed blood loss.

  9. PCR identification of bacteria in blood culture does not fit the daily workflow of a routine microbiology laboratory.

    PubMed

    Karumaa, Santra; Kärpänoja, Pauliina; Sarkkinen, Hannu

    2012-03-01

    We have evaluated the GenoType blood culture assay (Hain Lifescience, Nehren, Germany) for the identification of bacteria in 233 positive blood cultures and assessed its suitability in the workflow of a routine microbiology laboratory. In 68/233 (29.2%) samples, the culture result could not be confirmed by the GenoType assay due to a lack of primers in the test, multiple organisms in the sample, or inconsistency with respect to the identification by culture. Although the GenoType blood culture assay gives satisfactory results for bacteria for which primers are available, there are difficulties in applying the test in the routine microbiology laboratory.

  10. Quantitative Urine Culture Method Using a Plastic „Paddle” Containing Dual Media

    PubMed Central

    Craig, William A.; Kunin, Calvin M.

    1972-01-01

    A new dip-inoculum method for quantitative urine culture is described which utilizes a dual-chambered plastic „paddle” housing both a general purpose and differential medium. Comparative bacterial counts of 1,000 clinical specimens using the pour plate and this device were identical in 82.9% and within a factor of five in 95.6%. The „paddle” detected all but 19 of 258 specimens (92.6%) with 100,000 or greater colonies per ml. This simple, convenient method should allow more extensive use of quantitative urine culture in the diagnosis and follow-up of patients with urinary tract infections in office practice. It should not be considered as a substitute for the more definitive pour plate method or for standard methods for characterization of bacteriological species when more exact information is required. PMID:4555636

  11. Clinical and Laboratory Potential Predictors of Blood Culture Positivity in Under Five Children with Clinically Severe Pneumonia - Khartoum -Sudan.

    PubMed

    Salih, Karimeldin Mohamed Ali; El-Samani, El-Fatih; Bilal, Jalal Ali; Eldouch, Widad; Ibrahim, Salah Ahmed

    2015-08-01

    Blood culture is necessary for appropriate management of clinically severe pneumonia in children under five years of age. However, in limited resource countries it might be unduly costly and waste of valuable time because of the high negative culture rate. This study aims to identify clinical and laboratory parameters that potentially predict a positive blood culture in cases of severe pneumonia. A hospital based study, enrolled 189 cases satisfying the WHO definition of severe pneumonia. Age, gender, clinical history, physical examination, temperature, complete blood count, C-reactive protein, blood culture and Chest X Ray for all the patients were recorded. Forty one patients had positive blood culture giving a prevalence of 21.7%. All variables were used in a dichotomous manner. White Blood Count (WBC) more than 20 000, very high C-reactive protein (C-RP ≥8mg/L) and Temperature more than 40(o)C, had a positive predictive value of 46.1%, 44.3% and 40.0% respectively for a positive culture as well as a Negative Predictive Value of 91.1%, 91.6% and 91.7% respectively. The WBC more than 20 000 and temperature above 40(o)C had a significant association with a positive blood culture. Their adjusted Odds Ratios were 3.9 (95% CI: 1.4-10.90) and 3.1 (95% CI: 1.2-8.4) respectively. This was not the case for C-RP (Odds Ratio=2.2, 95% CI: 0.7-2.2) or positive Chest X Ray (Odds Ratio=1.5, 95% CI: 0.6-3.6). Temperature of more than 40(o)C, Very high C-RP and WBC of more than 20 000 are good indicators of a potential positive blood culture. It is therefore recommended that further research be undertaken to refine these predictors as screening tools before resorting to blood culture. It is also recommended that antibiotic treatment may be initiated on the basis of the high temperature and WBC, while waiting for the culture results.

  12. Using qualitative research methods in biomedical innovation: the case of cultured red blood cells for transfusion.

    PubMed

    Lyall, Catherine; King, Emma

    2016-05-11

    Qualitative research has a key role to play in biomedical innovation projects. This article focuses on the appropriate use of robust social science methodologies (primarily focus group studies) for identifying the public's willingness and preference for emerging medical technologies. Our study was part of the BloodPharma project (now known as the Novosang project) to deliver industrially generated red blood cells for transfusion. Previous work on blood substitutes shows that the public prefers donated human blood. However, no research has been conducted concerning attitudes to stem cell derived red blood cells. Qualitative research methods including interviews and focus groups provide the methodological context for this paper. Focus groups were used to elicit views from sub-sections of the UK population about the potential use of such cultured red blood cells. We reflect on the appropriateness of that methodology in the context of the BloodPharma project. Findings are in the form of lessons transferable to other interdisciplinary, science-led teams about what a social science dimension can bring; why qualitative research should be included; and how it can be used effectively. Qualitative data collection offers the strength of exploring ambivalence and investigating the reasons for views, but not necessarily their prevalence in wider society. The inherent value of a qualitative method, such as focus groups, therefore lies in its ability to uncover new information. This contrasts with a quantitative approach to simply 'measuring' public opinion on a topic about which participants may have little prior knowledge. We discuss a number of challenges including: appropriate roles for embedded social scientists and the intricacies of doing upstream engagement as well as some of the design issues and limitations associated with the focus group method.

  13. Identification of bacteria in blood culture broths using matrix-assisted laser desorption-ionization Sepsityper™ and time of flight mass spectrometry.

    PubMed

    Kok, Jen; Thomas, Lee C; Olma, Thomas; Chen, Sharon C A; Iredell, Jonathan R

    2011-01-01

    Matrix-assisted laser desorption ionization time of flight mass spectrometry (MALDI-TOF MS) is a novel method for the direct identification of bacteria from blood culture broths. We evaluate for the first time, the performance of the MALDI Sepsityper™ Kit and MS for the identification of bacteria compared to standard phenotypic methods using the manufacturer's specified bacterial identification criteria (spectral scores ≥1.700-1.999 and ≥2.000 indicated identification to genus and species level, respectively). Five hundred and seven positive blood culture broths were prospectively examined, of which 379 (74.8%; 358 monomicrobial, 21 polymicrobial) were identified by MALDI-TOF MS; 195 (100%) and 132 (67.7%) of 195 gram-positive; and 163 (100%) and 149 (91.4%) of 163 gram-negative organisms from monomicrobial blood cultures were correctly identified to genus and species level, respectively. Spectral scores <1.700 (no identification) were obtained in 128/507 (25.2%) positive blood culture broths, including 31.6% and 32.3% of gram-positive and polymicrobial blood cultures, respectively. Significantly more gram-negative organisms were identified compared to gram-positive organisms at species level (p<0.0001). Five blood cultures were misidentified, but at species level only; including four monomicrobial blood cultures with Streptococcus oralis/mitis that were misidentified as Streptococcus pneumoniae. Positive predictive values for the direct identification of both gram-positive and gram-negative bacteria from monomicrobial blood culture broths to genus level were 100%. A diagnostic algorithm for positive blood culture broths that incorporates gram staining and MALDI-TOF MS should identify the majority of pathogens, particularly to genus level.

  14. Time to Detection with BacT/Alert FA Plus Compared to BacT/Alert FA Blood Culture Media.

    PubMed

    Nutman, A; Fisher Even-Tsur, S; Shapiro, G; Braun, T; Schwartz, D; Carmeli, Y

    2016-09-01

    Rapid identification of the causative pathogen in patients with bacteremia allows adjustment of antibiotic therapy and improves patient outcomes. We compared in vitro and real-life time to detection (TTD) of two blood culture media, BacT/Alert FA (FA) and BacT/Alert FA Plus (FA Plus), for the nine most common species of bacterial pathogens recovered from blood samples. Experimental data from simulated cultures was compared with microbiology records of TTD for both culture media with growth of the species of interest in clinical blood cultures. In the experimental conditions, median TTD was 3.8 hours (23.9 %) shorter using FA Plus media. The magnitude of reduction differed between species. Similarly, in real life data, FA Plus had shorter TTD than FA media; however, the difference between culture media was smaller, and median TTD was only 1 hour (8.5 %) less. We found shorter TTD with BacT/Alert FA Plus culture media, both experimentally and in real-life conditions and unrelated to antibiotic neutralization, highlighting the importance of appropriate blood culture media selection.

  15. Comparison of the lysis centrifugation method with the conventional blood culture method in cases of sepsis in a tertiary care hospital.

    PubMed

    Parikh, Harshal R; De, Anuradha S; Baveja, Sujata M

    2012-07-01

    Physicians and microbiologists have long recognized that the presence of living microorganisms in the blood of a patient carries with it considerable morbidity and mortality. Hence, blood cultures have become critically important and frequently performed test in clinical microbiology laboratories for diagnosis of sepsis. To compare the conventional blood culture method with the lysis centrifugation method in cases of sepsis. Two hundred nonduplicate blood cultures from cases of sepsis were analyzed using two blood culture methods concurrently for recovery of bacteria from patients diagnosed clinically with sepsis - the conventional blood culture method using trypticase soy broth and the lysis centrifugation method using saponin by centrifuging at 3000 g for 30 minutes. Overall bacteria recovered from 200 blood cultures were 17.5%. The conventional blood culture method had a higher yield of organisms, especially Gram positive cocci. The lysis centrifugation method was comparable with the former method with respect to Gram negative bacilli. The sensitivity of lysis centrifugation method in comparison to conventional blood culture method was 49.75% in this study, specificity was 98.21% and diagnostic accuracy was 89.5%. In almost every instance, the time required for detection of the growth was earlier by lysis centrifugation method, which was statistically significant. Contamination by lysis centrifugation was minimal, while that by conventional method was high. Time to growth by the lysis centrifugation method was highly significant (P value 0.000) as compared to time to growth by the conventional blood culture method. For the diagnosis of sepsis, combination of the lysis centrifugation method and the conventional blood culture method with trypticase soy broth or biphasic media is advocable, in order to achieve faster recovery and a better yield of microorganisms.

  16. Towards cultural materialism in the medical humanities: the case of blood rejuvenation.

    PubMed

    Oakley, Catherine

    2018-03-01

    This paper argues for an approach within the medical humanities that draws on the theoretical legacy of cultural materialism as a framework for reading cultural practices and their relationship to the social and economic order. It revisits the origins and development of cultural materialism in cultural studies and literary studies between the 1970s and 1990s and considers how, with adaptation, this methodology might facilitate ideological criticism focused on material formations of health, disease and the human body. I outline three key characteristics of a medicocultural materialist approach along these lines: (a) interdisciplinary work on a broad range of medical and cultural sources, including those drawn from 'popular' forms of culture; (b) the combination of historicist analysis with scrutiny of present-day contexts; (c) analyses that engage with political economy perspectives and/or the work of medical sociology in this area. The subsequent sections of the paper employ a medicocultural materialist approach to examine conjectural understandings of, and empirical investigations into, the capacity of transfused human blood to rejuvenate the ageing body. I trace textual faultlines that expose the structures of power which inform the movement of blood between bodies in 'medical gothic' fictions from the 19th-century fin de siècle, including Mary Elizabeth Braddon's 'Good Lady Ducayne' (1896) and Bram Stoker's Dracula (1897). I conclude with a critique of biomedical innovations in blood rejuvenation in the era of medical neoliberalism, before considering the potential applications of medicocultural materialism to other topics within the field of the medical humanities. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  17. Polymerase chain reaction detection of Bartonella spp. in dogs from Spain with blood culture-negative infectious endocarditis.

    PubMed

    Roura, X; Santamarina, G; Tabar, M-D; Francino, O; Altet, L

    2018-05-25

    The presence of Bartonella spp. was detected by polymerase chain reaction (PCR) in dogs from Spain with blood culture-negative endocarditis. The aim of this study is to add information about canine infectious endocarditis in Europe. Thirty dogs with naturally occurring blood culture-negative endocarditis were examined from 2010 to 2017 at three veterinary referral hospitals, located in northwest, northeast, and southeast of Spain. It is a retrospective study. Medical records were reviewed to extract relevant data. Frozen or paraffin-embedded cardiac valve tissue and/or ethylenediamine tetraacetic acid blood samples were evaluated by PCR for the presence of Bartonella DNA. Positive results were sequenced to confirm the species. Polymerase chain reaction was positive for eight out of 30 dogs included (26.6%). Bartonella rochalimae, Bartonella vinsonii subsp. berkhoffii, and Bartonella koehlerae were detected in valve tissue or blood. Bartonella could be an important cause of blood culture-negative infectious endocarditis in dogs from Spain. The outcome for those dogs affected with Bartonella spp. was grave. Prompt empirical treatment with amoxicillin-clavulanate plus fluoroquinolones could be of value in cases of blood culture-negative endocarditis. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Influence of postmortem time on the outcome of blood cultures among cadaveric tissue donors.

    PubMed

    Saegeman, V; Verhaegen, J; Lismont, D; Verduyckt, B; De Rijdt, T; Ectors, N

    2009-02-01

    Tissue banks provide tissues of human cadaver donors for transplantation. The maximal time limit for tissue retrieval has been set at 24 h postmortem. This study aimed at evaluating the evidence for this limit from a microbiological point of view. The delay of growth in postmortem blood cultures, the identification of the species isolated and clinical/environmental factors were investigated among 100 potential tissue donors. No significant difference was found in the rate of donors with grown blood cultures within (25/65=38%) compared with after (24/65=37%) 24 h of death. Coagulase-negative staphylococci and gastro-intestinal microorganisms were isolated within and after 24 h of death. Two factors--antimicrobial therapy and "delay before body cooling"--were significantly inversely related with donors' blood culture results. From a microbiological point of view, there is no evidence for avoiding tissue retrieval among donors after 24 h of death.

  19. Diagnosis of brucellosis by using blood cultures.

    PubMed Central

    Ruiz, J; Lorente, I; Pérez, J; Simarro, E; Martínez-Campos, L

    1997-01-01

    The performances of three blood culture systems, Hemoline performance diphasic medium (bioMérieux, Marcy l'Etoile, France), Bactec Plus Aerobic/F* (Becton Dickinson, Paramus, N.J.), and Vital Aer (bioMérieux), were compared for the diagnosis of 17 cases of brucellosis. By using a 5-day incubation protocol, positive results were 52.9, 82.4, and 11.8%, respectively. When the protocol was extended to 7 days, the results were 76.5, 94.1, and 47.1%, respectively. Bactec was the fastest system (P < 0.05). PMID:9276429

  20. Studies that report unexpected positive blood cultures for Lyme borrelia - are they valid?

    PubMed

    Wormser, Gary P; Shapiro, Eugene D; Strle, Franc

    2017-11-01

    Positive blood cultures for Lyme borrelia have been well documented in untreated patients with early Lyme disease. In this report we review the validity of three studies that reported the recovery of Borrelia burgdorferi sensu lato from the blood of a high proportion of patients for whom no evidence was presented, and no claim was made, that the patients had untreated early Lyme disease. In two of the studies the patients had been treated extensively with antibiotics for Lyme disease before the cultures were obtained. Critical evaluation of the three reports suggests that they are invalid. Indeed, two subsequently published studies could not reproduce the results of one of the reports. In a published analysis of another of the reports, investigators from the Centers for Disease Control and Prevention concluded that the cultures were likely to have been contaminated. When the biologic plausibility of recovering borrelia from blood is extremely low, the level of scientific rigor required of a study that claims a positive result should be particularly high. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Use of Blood Smears and Dried Blood Spots for Polymerase Chain Reaction–Based Detection and Quantification of Bacterial Infection and Plasmodium falciparum in Severely Ill Febrile African Children

    PubMed Central

    Wihokhoen, Benchawan; Dondorp, Arjen M.; Turner, Paul; Woodrow, Charles J.; Imwong, Mallika

    2016-01-01

    Molecular approaches offer a means of testing archived samples stored as dried blood spots in settings where standard blood cultures are not possible. Peripheral blood films are one suggested source of material, although the sensitivity of this approach has not been well defined. Thin blood smears and dried blood spots from a severe pediatric malaria study were assessed using specific polymerase chain reaction (PCR) primers to detect non-typhoidal Salmonella (NTS; MisL gene), Streptococcus pneumoniae (lytA), and Plasmodium falciparum (18S rRNA). Of 16 cases of NTS and S. pneumoniae confirmed on blood culture, none were positive by PCR using DNA extracts from blood films or dried blood spots. In contrast, four of 36 dried blood spots and two of 178 plasma samples were PCR positive for S. pneumoniae, despite negative bacterial blood cultures, suggesting false positives. Quantitative assessment revealed that the effective concentration of P. falciparum DNA in blood films was three log orders of magnitude lower than for dried blood spots. The P. falciparum kelch13 gene could not be amplified from blood films. These findings question the value of blood PCR-based approaches for detection of NTS and S. pneumoniae, and show that stored blood films are an inefficient method of studying P. falciparum. PMID:26711525

  2. Quantitative cultures of bronchoscopically obtained specimens should be performed for optimal management of ventilator-associated pneumonia.

    PubMed

    Baselski, Vickie; Klutts, J Stacey; Baselski, Vickie; Klutts, J Stacey

    2013-03-01

    Ventilator-associated pneumonia (VAP) is a leading cause of health care-associated infection. It has a high rate of attributed mortality, and this mortality is increased in patients who do not receive appropriate empirical antimicrobial therapy. As a result of the overuse of broad-spectrum antimicrobials such as the carbapenems, strains of Acinetobacter, Enterobacteriaceae, and Pseudomonas aeruginosa susceptible only to polymyxins and tigecycline have emerged as important causes of VAP. The need to accurately diagnose VAP so that appropriate discontinuation or de-escalation of antimicrobial therapy can be initiated to reduce this antimicrobial pressure is essential. Practice guidelines for the diagnosis of VAP advocate the use of bronchoalveolar lavage (BAL) fluid obtained either bronchoscopically or by the use of a catheter passed through the endotracheal tube. The CDC recommends that quantitative cultures be performed on these specimens, using ≥ 10(4) CFU/ml to designate a positive culture (http://www.cdc.gov/nhsn/TOC_PSCManual.html, accessed 30 October 2012). However, there is no consensus in the clinical microbiology community as to whether these specimens should be cultured quantitatively, using the aforementioned designated bacterial cell count to designate infection, or by a semiquantitative approach. We have asked Vickie Baselski, University of Tennessee Health Science Center, who was the lead author on one of the seminal papers on quantitative BAL fluid culture, to explain why she believes that quantitative BAL fluid cultures are the optimal strategy for VAP diagnosis. We have Stacey Klutts, University of Iowa, to advocate the semiquantitative approach.

  3. Understanding Bacterial Isolates in Blood Culture and Approaches Used to Define Bacteria as Contaminants: A Literature Review.

    PubMed

    Hossain, Belal; Islam, Mohammad Shahidul; Rahman, Atiqur; Marzan, Mahfuza; Rafiqullah, Iftekhar; Connor, Nicholas E; Hasanuzzaman, Mohammad; Islam, Maksuda; Hamer, Davidson H; Hibberd, Patricia L; Saha, Samir K

    2016-05-01

    Interpretation of blood culture isolates is challenging due to a lack of standard methodologies for identifying contaminants. This problem becomes more complex when the specimens are from sick young infants, as a wide range of bacteria can cause illness among this group. We used 43 key words to find articles published between 1970 and 2011 on blood culture isolates and possible contaminants in the PubMed database. Experts were also consulted to obtain other relevant articles. Selection of articles followed systematic methods considering opinions from more than 1 reviewer. After reviewing the titles of 3869 articles extracted from the database, we found 307 relevant to our objective. Based on the abstracts, 42 articles were selected for the literature review. In addition, we included 7 more articles based on cross-references and expert advice. The most common methods for differentiating blood culture isolates were multiple blood cultures from the same subject, antibiograms and molecular testing. Streptococcus pneumoniae, Hemophilus influenzae, Neisseria meningitidis and group A and B streptococcus were always considered as pathogens, whereas Bacillus sp., Diphtheroids, Propionibacterium and Micrococcus were commonly regarded as contaminants. Coagulase-negative staphylococci were the most frequent isolates and usually reported as contaminants unless the patient had a specific condition, such as long-term hospitalization or use of invasive devices (catheters). Inaccurate interpretation of blood culture may falsely guide treatment and also has long-term policy implications. The combination of clinical and microbiological knowledge, patient's clinical history and laboratory findings are essential for appropriate interpretation of blood culture.

  4. Quantitative determination of opioids in whole blood using fully automated dried blood spot desorption coupled to on-line SPE-LC-MS/MS.

    PubMed

    Verplaetse, Ruth; Henion, Jack

    2016-01-01

    Opioids are well known, widely used painkillers. Increased stability of opioids in the dried blood spot (DBS) matrix compared to blood/plasma has been described. Other benefits provided by DBS techniques include point-of-care collection, less invasive micro sampling, more economical shipment, and convenient storage. Current methodology for analysis of micro whole blood samples for opioids is limited to the classical DBS workflow, including tedious manual punching of the DBS cards followed by extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS) bioanalysis. The goal of this study was to develop and validate a fully automated on-line sample preparation procedure for the analysis of DBS micro samples relevant to the detection of opioids in finger prick blood. To this end, automated flow-through elution of DBS cards was followed by on-line solid-phase extraction (SPE) and analysis by LC-MS/MS. Selective, sensitive, accurate, and reproducible quantitation of five representative opioids in human blood at sub-therapeutic, therapeutic, and toxic levels was achieved. The range of reliable response (R(2)  ≥0.997) was 1 to 500 ng/mL whole blood for morphine, codeine, oxycodone, hydrocodone; and 0.1 to 50 ng/mL for fentanyl. Inter-day, intra-day, and matrix inter-lot accuracy and precision was less than 15% (even at lower limits of quantitation (LLOQ) level). The method was successfully used to measure hydrocodone and its major metabolite norhydrocodone in incurred human samples. Our data support the enormous potential of DBS sampling and automated analysis for monitoring opioids as well as other pharmaceuticals in both anti-doping and pain management regimens. Copyright © 2015 John Wiley & Sons, Ltd.

  5. [Rapid identification of microorganisms by mass spectrometry in a blood culture system. Comparison of two procedures].

    PubMed

    Cattani, María E; Posse, Tamara; Hermes, Ricardo L; Kaufman, Sara C

    2015-01-01

    Rapid identification of microorganisms is critical in hospitalized infected patients. Blood culture is currently the gold standard for detecting and identifying microorganisms causing bacteremia or sepsis. The introduction of mass spectrometry by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF MS) in microbiology laboratories, especially in microorganisms growing in blood culture bottles, provides rapid identification. This study evaluates the performance of the Maldi Sepsityper Biotyper procedure (hereinafter, MS) compared to that of an in-home method (hereinafter, HF). Eight hundred and forty (840) positive blood culture bottles were processed using the HF procedure, 542 of which were also processed using MS. The organisms were identified in 670 (79.76%) and 391 (72.14%) bottles respectively (p = 0,0013). This study demonstrates the effectiveness of both procedures for identifying microorganisms directly from positive blood culture bottles. However, the HF procedure proved to be more effective than MS, especially in the presence of Gram positive organisms. Copyright © 2015 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. Efficacy of the FilmArray blood culture identification panel for direct molecular diagnosis of infectious diseases from samples other than blood.

    PubMed

    Micó, Miquel; Navarro, Ferran; de Miniac, Daniela; González, Yésica; Brell, Albert; López, Cristina; Sánchez-Reus, Ferran; Mirelis, Beatriz; Coll, Pere

    2015-12-01

    Molecular-based techniques reduce the delay in diagnosing infectious diseases and therefore contribute to better patient outcomes. We assessed the FilmArray blood culture identification (BCID) panel (Biofire Diagnostics/bioMérieux) directly on clinical specimens other than blood: cerebrospinal, joint, pleural and ascitic fluids, bronchoscopy samples and abscesses. We compared the results from 88 samples obtained by culture-based techniques. The percentage of agreement between the two methods was 75 % with a Cohen κ value of 0.51. Global sensitivity and specificity using the FilmArray BCID panel were 71 and 97 %, respectively. Sensitivity was poorer in samples with a low bacterial load, such as ascitic and pleural fluids (25 %), whereas the sensitivity for abscess samples was high (89 %). These findings suggest that the FilmArray BCID panel could be useful to perform microbiological diagnosis directly from samples other than positive blood cultures, as it offers acceptable sensitivity and moderate agreement with conventional microbiological methods. Nevertheless, cost-benefit studies should be performed before introducing this method into algorithms for microbiological diagnostics.

  7. [Stimulation of cell cultures recovery after cryopreservation by the cattle cord blood FRACTION (below 5 kDa) or Actovegin].

    PubMed

    Gulevskiĭ, A K; Trifonova, A V; Lavrik, A A

    2013-01-01

    The capacities of the cattle cord blood low-molecular fraction (below 5 kDa) and Actovegin (the vealer blood fraction (below 5 kDa)) for recovering functions of cell cultures after cryopreservation compared. Their influence proliferation of the flozen-thawed cell cultures, certain stages of their growth, cell attachment, rate of cell spreading, and mitotic regiment has been studied. Both the cord blood low-molecular fraction and Actovegin were shown to stimulate growth of the cell cultures after cryopreservation more efficiently at the concentration of 224 μg/ml. However, despite the stimulating effect discovered, their application did not bring proliferative indices on the 1st passage after cryopreservation to the values of the native culture. The effects of the cord blood low-molecular fraction and Actovegin on the human fibroblast culture were identical by the following parameters: cell attachment, rates of cell spreading and proliferation. In culture BHK-21 clone 13/04 the efficiency of Actovegin was low, while the cord blood low-molecular fraction has a conspicuous stimulating effect on its adhesion and proliferation. The investigations carried out can serve as a basis for the development of regenerative media containing the cattle cord blood low-molecular fraction (below 5 kDa) or Actovegin as active components at the concentration of 224 μg/ml with the purpose of fast recovery of culture prolifetative properties after cryopreservation.

  8. Quantitative relationship between the octanol/water partition coefficient and the diffusion limitation of the exchange between adipose and blood.

    PubMed

    Levitt, David G

    2010-01-07

    The goal of physiologically based pharmacokinetics (PBPK) is to predict drug kinetics from an understanding of the organ/blood exchange. The standard approach is to assume that the organ is "flow limited" which means that the venous blood leaving the organ equilibrates with the well-stirred tissue compartment. Although this assumption is valid for most solutes, it has been shown to be incorrect for several very highly fat soluble compounds which appear to be "diffusion limited". This paper describes the physical basis of this adipose diffusion limitation and its quantitative dependence on the blood/water (Kbld-wat) and octanol/water (Kow) partition coefficient. Experimental measurements of the time dependent rat blood and adipose concentration following either intravenous or oral input were used to estimate the "apparent" adipose perfusion rate (FA) assuming that the tissue is flow limited. It is shown that the ratio of FA to the anatomic perfusion rate (F) provides a measure of the diffusion limitation. A quantitative relationship between this diffusion limitation and Kbld-wat and Kow is derived. This analysis was applied to previously published data, including the Oberg et. al. measurements of the rat plasma and adipose tissue concentration following an oral dose of a mixture of 13 different polychlorinated biphenyls. Solutes become diffusion limited at values of log Kow greater than about 5.6, with the adipose-blood exchange rate reduced by a factor of about 30 for a solute with a log Kow of 7.36. Quantitatively, a plot of FA/F versus Kow is well described assuming an adipose permeability-surface area product (PS) of 750/min. This PS corresponds to a 0.14 micron aqueous layer separating the well-stirred blood from the adipose lipid. This is approximately equal to the thickness of the rat adipose capillary endothelium. These results can be used to quantitate the adipose-blood diffusion limitation as a function of Kow. This is especially important for the highly

  9. Identification of malaria infected red blood samples by digital holographic quantitative phase microscope

    NASA Astrophysics Data System (ADS)

    Patel, Nimit R.; Chhaniwal, Vani K.; Javidi, Bahram; Anand, Arun

    2015-07-01

    Development of devices for automatic identification of diseases is desired especially in developing countries. In the case of malaria, even today the gold standard is the inspection of chemically treated blood smears through a microscope. This requires a trained technician/microscopist to identify the cells in the field of view, with which the labeling chemicals gets attached. Bright field microscopes provide only low contrast 2D images of red blood cells and cell thickness distribution cannot be obtained. Quantitative phase contrast microscopes can provide both intensity and phase profiles of the cells under study. The phase information can be used to determine thickness profile of the cell. Since cell morphology is available, many parameters pertaining to the 3D shape of the cell can be computed. These parameters in turn could be used to decide about the state of health of the cell leading to disease diagnosis. Here the investigations done on digital holographic microscope, which provides quantitative phase images, for comparison of parameters obtained from the 3D shape profile of objects leading to identification of diseased samples is described.

  10. Magnetic fingerprints of rolling cells for quantitative flow cytometry in whole blood

    NASA Astrophysics Data System (ADS)

    Reisbeck, Mathias; Helou, Michael Johannes; Richter, Lukas; Kappes, Barbara; Friedrich, Oliver; Hayden, Oliver

    2016-09-01

    Over the past 50 years, flow cytometry has had a profound impact on preclinical and clinical applications requiring single cell function information for counting, sub-typing and quantification of epitope expression. At the same time, the workflow complexity and high costs of such optical systems still limit flow cytometry applications to specialized laboratories. Here, we present a quantitative magnetic flow cytometer that incorporates in situ magnetophoretic cell focusing for highly accurate and reproducible rolling of the cellular targets over giant magnetoresistance sensing elements. Time-of-flight analysis is used to unveil quantitative single cell information contained in its magnetic fingerprint. Furthermore, we used erythrocytes as a biological model to validate our methodology with respect to precise analysis of the hydrodynamic cell diameter, quantification of binding capacity of immunomagnetic labels, and discrimination of cell morphology. The extracted time-of-flight information should enable point-of-care quantitative flow cytometry in whole blood for clinical applications, such as immunology and primary hemostasis.

  11. Evaluation of the FilmArray Blood Culture Identification Panel: Results of a Multicenter Controlled Trial

    PubMed Central

    Salimnia, Hossein; Lephart, Paul R.; Schreckenberger, Paul; DesJarlais, Sharon M.; Johnson, J. Kristie; Robinson, Gwen; Carroll, Karen C.; Greer, Amy; Morgan, Margie; Chan, Raymond; Loeffelholz, Michael; Valencia-Shelton, Frances; Jenkins, Stephen; Schuetz, Audrey N.; Daly, Judy A.; Barney, Trenda; Hemmert, Andrew; Kanack, Kristen J.

    2016-01-01

    Sepsis is a major cause of morbidity, mortality, and increased medical expense. Rapid diagnosis improves outcomes and reduces costs. The FilmArray blood culture identification panel (BioFire Diagnostics LLC, Salt Lake City, UT), a highly multiplexed PCR assay, can identify 24 etiologic agents of sepsis (8 Gram-positive, 11 Gram-negative, and 5 yeast species) and three antimicrobial resistance genes (mecA, vanA/B, and blaKPC) from positive blood culture bottles. It provides results in about 1 h with 2 min for assay setup. We present the results of an eight-center trial comparing the sensitivity and specificity of the panel with those of the laboratories' standard phenotypic identification techniques, as well as with molecular methods used to distinguish Acinetobacter baumannii from other members of the A. calcoaceticus-A. baumannii complex and to detect antimicrobial resistance genes. Testing included 2,207 positive aerobic blood culture samples, 1,568 clinical and 639 seeded. Samples were tested fresh or were frozen for later testing within 8 h after the bottles were flagged as positive by an automated blood culture system. At least one organism was detected by the panel in 1,382 (88.1%) of the positive clinical specimens. The others contained primarily off-panel organisms. The panel reported multiple organisms in 81 (5.86%) positive clinical specimens. The unresolved blood culture identification sensitivity for all target detections exceeded 96%, except for Klebsiella oxytoca (92.2%), which achieved 98.3% sensitivity after resolution of an unavoidable phenotypic error. The sensitivity and specificity for vanA/B and blaKPC were 100%; those for mecA were 98.4 and 98.3%, respectively. PMID:26739158

  12. Multicenter evaluation of the Sepsityper™ extraction kit and MALDI-TOF MS for direct identification of positive blood culture isolates using the BD BACTEC™ FX and VersaTREK(®) diagnostic blood culture systems.

    PubMed

    Schieffer, K M; Tan, K E; Stamper, P D; Somogyi, A; Andrea, S B; Wakefield, T; Romagnoli, M; Chapin, K C; Wolk, D M; Carroll, K C

    2014-04-01

    (i) Evaluation of delayed time to blood culture extraction by the Sepsityper kit and impact of shipping pellets off-site for MALDI-TOF MS analysis. (ii) Comparison of Sepsityper and laboratory-developed extraction methods from a literature review. Using two blood culture systems (BD BACTEC and VersaTREK), we extracted 411 positive blood cultures using the Sepsityper kit to mimic a potential protocol for institutions without a MALDI-TOF MS. Extracted pellets were shipped and analysed on the Bruker UltraflexIII. Successful extraction of 358 (87·1%) samples was determined by the presence of detectable proteins. MALDI-TOF MS correctly identified 332 (80·8%) samples. Delayed time to extraction did not affect Sepsityper extraction or MALDI-TOF MS accuracy. The extracted pellets remain stable and provide accurate results by MALDI-TOF MS when shipped at room temperature to off-site reference laboratories. This is the first study to show that institutions without a MALDI-TOF MS can take advantage of this innovative technology by shipping a volume of blood to an off-site laboratory for extraction and MALDI-TOF MS analysis. We also performed a literature review to compare various extraction methods. © 2014 The Society for Applied Microbiology.

  13. Optimal turnaround time for direct identification of microorganisms by mass spectrometry in blood culture.

    PubMed

    Randazzo, Adrien; Simon, Marc; Goffinet, Pierre; Classen, Jean-François; Hougardy, Nicolas; Pierre, Pascal; Kinzinger, Philippe; Mauel, Etienne; Goffinet, Jean-Sébastien

    2016-11-01

    During the past few years, several studies describing direct identification of bacteria from blood culture using mass spectrometry have been published. These methods cannot, however, be easily integrated into a common laboratory workflow because of the high hands-on time they require. In this paper, we propose a new method of identification with a short hands-on time and a turnaround time shorter than 15min. Positive blood bottles were homogenised and 600μL of blood were transferred to an Eppendorf tube where 600μL of lysis buffer were added. After homogenisation, a centrifugation step of 4min at 10,500g was performed and the supernatant was discarded. The pellet was then washed and loaded in quadruplicate into wells of a Vitek® MS-DS plate. Each well was covered with a saturated matrix solution and a MALDI-TOF mass spectrometry analysis was performed. Species were identified using the software Myla 3.2.0-2. We analysed 266 positive blood culture bottles. A microorganism grew in 261 cultures, while five bottles remained sterile after 48h of incubation in subculture. Our method reaches a probability of detection at the species level of 77.8% (203/261) with a positive predictive value of 99.5% (202/203). We developed a new method for the identification of microorganisms using mass spectrometry, directly performed from a positive blood culture. This method has short hands-on time and turnaround time and can easily take place in the workflow of a laboratory, with comparable results in performance with other methods reported in the literature. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Usefulness of gram staining of blood collected from total parenteral nutrition catheter for rapid diagnosis of catheter-related sepsis.

    PubMed Central

    Moonens, F; el Alami, S; Van Gossum, A; Struelens, M J; Serruys, E

    1994-01-01

    The accuracy of Gram staining of blood drawn from catheters used to administer total parenteral nutrition was compared with paired quantitative blood cultures for the diagnosis of catheter-related sepsis. Gram staining was positive in 11 of 18 episodes of catheter-related sepsis documented by quantitative culture (sensitivity, 61%) but in none of the 5 episodes of fever unrelated to catheter infection. Thus, this procedure enabled the rapid presumptive diagnosis and guidance of antimicrobial therapy for total parenteral nutrition catheter sepsis, with a positive predictive value of 100% and a negative predictive value of 42%. PMID:7521359

  15. Flow cytometric quantitation of phagocytosis in heparinized complete blood with latex particles and Candida albicans.

    PubMed

    Egido, J M; Viñuelas, J

    1997-01-01

    We report a rapid method for the flow cytometric quantitation of phagocytosis in heparinized complete peripheral blood (HCPB), using commercially available phycoerythrin-conjugated latex particles of 1 micron diameter. The method is faster and shows greater reproducibility than Bjerknes' (1984) standard technique using propidium iodide-stained Candida albicans, conventionally applied to the leukocytic layer of peripheral blood but here modified for HCPB. We also report a modification of Bjerknes' Intracellular Killing Test to allow its application to HCPB.

  16. Gram-negative and -positive bacteria differentiation in blood culture samples by headspace volatile compound analysis.

    PubMed

    Dolch, Michael E; Janitza, Silke; Boulesteix, Anne-Laure; Graßmann-Lichtenauer, Carola; Praun, Siegfried; Denzer, Wolfgang; Schelling, Gustav; Schubert, Sören

    2016-12-01

    Identification of microorganisms in positive blood cultures still relies on standard techniques such as Gram staining followed by culturing with definite microorganism identification. Alternatively, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry or the analysis of headspace volatile compound (VC) composition produced by cultures can help to differentiate between microorganisms under experimental conditions. This study assessed the efficacy of volatile compound based microorganism differentiation into Gram-negatives and -positives in unselected positive blood culture samples from patients. Headspace gas samples of positive blood culture samples were transferred to sterilized, sealed, and evacuated 20 ml glass vials and stored at -30 °C until batch analysis. Headspace gas VC content analysis was carried out via an auto sampler connected to an ion-molecule reaction mass spectrometer (IMR-MS). Measurements covered a mass range from 16 to 135 u including CO2, H2, N2, and O2. Prediction rules for microorganism identification based on VC composition were derived using a training data set and evaluated using a validation data set within a random split validation procedure. One-hundred-fifty-two aerobic samples growing 27 Gram-negatives, 106 Gram-positives, and 19 fungi and 130 anaerobic samples growing 37 Gram-negatives, 91 Gram-positives, and two fungi were analysed. In anaerobic samples, ten discriminators were identified by the random forest method allowing for bacteria differentiation into Gram-negative and -positive (error rate: 16.7 % in validation data set). For aerobic samples the error rate was not better than random. In anaerobic blood culture samples of patients IMR-MS based headspace VC composition analysis facilitates bacteria differentiation into Gram-negative and -positive.

  17. Rapid identification of bacteria in positive blood culture by matrix-assisted laser desorption ionization time-of-flight mass spectrometry.

    PubMed

    Schmidt, V; Jarosch, A; März, P; Sander, C; Vacata, V; Kalka-Moll, W

    2012-03-01

    Blood culture is probably the most significant specimen used for the diagnosis of bacterial infections, especially for bloodstream infections. In the present study, we compared the resin-containing BD BACTEC™ Plus-Aerobic (Becton Dickinson), non-charcoal-containing BacT/Alert(®) SA (bioMérieux), and charcoal-containing BacT/Alert(®) FA (bioMérieux) blood culture bottles with direct identification by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS). A total of 103 bacterial isolates, from clinical blood cultures, representing the most frequent 13 genera and 24 species were examined. Bacteria were extracted from positive blood culture broth by density centrifugation and then subjected to identification by MALDI-TOF MS using two different volumes and chemical treatments. Overall, correct identification by MALDI-TOF MS was obtained for the BD BACTEC™ Plus-Aerobic, BacT/Alert(®) SA, and BacT/Alert(®) FA blood culture bottles in 72%, 45.6%, and 23%, respectively, for gram-negative bacteria in 86.6%, 69.2%, and 47.1%, respectively, and for gram-positive bacteria in 60.0%, 28.8%, and 5.4%, respectively. The lack of identification was observed mainly with viridans streptococci. Depending on the blood culture bottles used in routine diagnostic procedures and the protocol for bacterial preparation, the applied MALDI-TOF MS represents an efficient and rapid method for direct bacterial identification.

  18. Does maternal intrapartum antibiotic treatment prolong the incubation time required for blood cultures to become positive for infants with early-onset sepsis?

    PubMed

    Sarkar, Siddhartha Sean; Bhagat, Indira; Bhatt-Mehta, Varsha; Sarkar, Subrata

    2015-03-01

    We hypothesized that maternal intrapartum antibiotic treatment delays the growth of the organism in the blood culture obtained during the work-up for infants with suspected early-onset sepsis (EOS). Single center, retrospective review of infants with blood culture-proven EOS over 13.5 years period. EOS was defined by isolation of a pathogen from blood culture obtained within 72 hours of birth and antibiotic treatment for  ≥ 5 days. Among 81 infants with positive blood cultures, 38 were deemed to have EOS and 43 were deemed contaminants. The organisms grown were as follows: Escherichia coli in 17 infants, Group B streptococcus in 10 infants, and others in 11 infants. Overall, 17 infants with EOS did not receive intrapartum antibiotics and had blood cultures drawn for being symptomatic after birth. The other 21 infants who received intrapartum antibiotics had blood culture drawn primarily for maternal chorioamnionitis. The median (interquartile range [IQR]) incubation time to blood culture positivity was not different in infants who received intrapartum antibiotics compared with infants who did not (19.6 hours, IQR 16-28 hours vs. 19.5 hours, IQR 17.2-21.6 hours, p = 0.7489). Maternal intrapartum antibiotic treatment did not delay the time to blood culture positivity in infants with EOS. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  19. Use of Blood Smears and Dried Blood Spots for Polymerase Chain Reaction-Based Detection and Quantification of Bacterial Infection and Plasmodium falciparum in Severely Ill Febrile African Children.

    PubMed

    Wihokhoen, Benchawan; Dondorp, Arjen M; Turner, Paul; Woodrow, Charles J; Imwong, Mallika

    2016-02-01

    Molecular approaches offer a means of testing archived samples stored as dried blood spots in settings where standard blood cultures are not possible. Peripheral blood films are one suggested source of material, although the sensitivity of this approach has not been well defined. Thin blood smears and dried blood spots from a severe pediatric malaria study were assessed using specific polymerase chain reaction (PCR) primers to detect non-typhoidal Salmonella (NTS; MisL gene), Streptococcus pneumoniae (lytA), and Plasmodium falciparum (18S rRNA). Of 16 cases of NTS and S. pneumoniae confirmed on blood culture, none were positive by PCR using DNA extracts from blood films or dried blood spots. In contrast, four of 36 dried blood spots and two of 178 plasma samples were PCR positive for S. pneumoniae, despite negative bacterial blood cultures, suggesting false positives. Quantitative assessment revealed that the effective concentration of P. falciparum DNA in blood films was three log orders of magnitude lower than for dried blood spots. The P. falciparum kelch13 gene could not be amplified from blood films. These findings question the value of blood PCR-based approaches for detection of NTS and S. pneumoniae, and show that stored blood films are an inefficient method of studying P. falciparum. © The American Society of Tropical Medicine and Hygiene.

  20. Blood cultures taken from patients attending emergency departments in South Africa are an important antibiotic stewardship tool, which directly influences patient management.

    PubMed

    Boyles, Tom H; Davis, Kelly; Crede, Thomas; Malan, Jacques; Mendelson, Marc; Lesosky, Maia

    2015-10-06

    Febrile illness with suspected blood stream infection (BSI) is a common reason for admission to hospital in Africa and blood cultures are therefore an important investigation. Data on the prevalence and causes of community acquired BSI in Africa are scarce and there are no studies from South Africa. There are no validated clinical prediction rules for use of blood cultures in Africa. A prospective observational cohort study of patients attending 2 urban emergency departments in Cape Town, South Africa. The decision to take a blood culture was made by the attending clinician and information available at the time of blood draw was collected. Bottles were weighed to measure volume of blood inoculated. 500 blood culture sets were obtained from 489 patients. 39 (7.8 %) were positive for pathogens and 13 (2.6 %) for contaminants. Significant independent predictors of positive cultures were diastolic blood pressure <60 mmHg, pulse >120 bpm, diabetes and a suspected biliary source of infection, but not HIV infection. Positive results influenced patient management in 36 of 38 (95 %) cases with the organism being resistant to the chosen empiric antibiotic in 9 of 38 (24 %). Taking <8 ml of blood was predictive of a negative culture. The best clinical prediction rule had a negative predictive value (NPV) of 92 % which is unlikely to be high enough to be clinically useful. Blood cultures taken from patients attending emergency departments in a high HIV prevalent city in South Africa are frequently positive and almost always influence patient management. At least 8 ml of blood should be inoculated into each bottle. Blood cultures should be taken from all patients attending EDs in South Africa suspected of having BSI particularly if diabetic, with hypotension, tachycardia or if biliary sepsis is suspected.

  1. Quantitative agreement between [(15)O]H2O PET and model free QUASAR MRI-derived cerebral blood flow and arterial blood volume.

    PubMed

    Heijtel, D F R; Petersen, E T; Mutsaerts, H J M M; Bakker, E; Schober, P; Stevens, M F; van Berckel, B N M; Majoie, C B L M; Booij, J; van Osch, M J P; van Bavel, E T; Boellaard, R; Lammertsma, A A; Nederveen, A J

    2016-04-01

    The purpose of this study was to assess whether there was an agreement between quantitative cerebral blood flow (CBF) and arterial cerebral blood volume (CBVA) measurements by [(15)O]H2O positron emission tomography (PET) and model-free QUASAR MRI. Twelve healthy subjects were scanned within a week in separate MRI and PET imaging sessions, after which quantitative and qualitative agreement between both modalities was assessed for gray matter, white matter and whole brain region of interests (ROI). The correlation between CBF measurements obtained with both modalities was moderate to high (r(2): 0.28-0.60, P < 0.05), although QUASAR significantly underestimated CBF by 30% (P < 0.001). CBVA was moderately correlated (r(2): 0.28-0.43, P < 0.05), with QUASAR yielding values that were only 27% of the [(15)O]H2O-derived values (P < 0.001). Group-wise voxel statistics identified minor areas with significant contrast differences between [(15)O]H2O PET and QUASAR MRI, indicating similar qualitative CBVA and CBF information by both modalities. In conclusion, the results of this study demonstrate that QUASAR MRI and [(15)O]H2O PET provide similar CBF and CBVA information, but with systematic quantitative discrepancies. Copyright © 2016 John Wiley & Sons, Ltd.

  2. Cerebral Blood Volume ASPECTS Is the Best Predictor of Clinical Outcome in Acute Ischemic Stroke: A Retrospective, Combined Semi-Quantitative and Quantitative Assessment.

    PubMed

    Padroni, Marina; Bernardoni, Andrea; Tamborino, Carmine; Roversi, Gloria; Borrelli, Massimo; Saletti, Andrea; De Vito, Alessandro; Azzini, Cristiano; Borgatti, Luca; Marcello, Onofrio; d'Esterre, Christopher; Ceruti, Stefano; Casetta, Ilaria; Lee, Ting-Yim; Fainardi, Enrico

    2016-01-01

    The capability of CT perfusion (CTP) Alberta Stroke Program Early CT Score (ASPECTS) to predict outcome and identify ischemia severity in acute ischemic stroke (AIS) patients is still questioned. 62 patients with AIS were imaged within 8 hours of symptom onset by non-contrast CT, CT angiography and CTP scans at admission and 24 hours. CTP ASPECTS was calculated on the affected hemisphere using cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) maps by subtracting 1 point for any abnormalities visually detected or measured within multiple cortical circular regions of interest according to previously established thresholds. MTT-CBV ASPECTS was considered as CTP ASPECTS mismatch. Hemorrhagic transformation (HT), recanalization status and reperfusion grade at 24 hours, final infarct volume at 7 days and modified Rankin scale (mRS) at 3 months after onset were recorded. Semi-quantitative and quantitative CTP ASPECTS were highly correlated (p<0.00001). CBF, CBV and MTT ASPECTS were higher in patients with no HT and mRS ≤ 2 and inversely associated with final infarct volume and mRS (p values: from p<0.05 to p<0.00001). CTP ASPECTS mismatch was slightly associated with radiological and clinical outcomes (p values: from p<0.05 to p<0.02) only if evaluated quantitatively. A CBV ASPECTS of 9 was the optimal semi-quantitative value for predicting outcome. Our findings suggest that visual inspection of CTP ASPECTS recognizes infarct and ischemic absolute values. Semi-quantitative CBV ASPECTS, but not CTP ASPECTS mismatch, represents a strong prognostic indicator, implying that core extent is the main determinant of outcome, irrespective of penumbra size.

  3. Cerebral Blood Volume ASPECTS Is the Best Predictor of Clinical Outcome in Acute Ischemic Stroke: A Retrospective, Combined Semi-Quantitative and Quantitative Assessment

    PubMed Central

    Padroni, Marina; Bernardoni, Andrea; Tamborino, Carmine; Roversi, Gloria; Borrelli, Massimo; Saletti, Andrea; De Vito, Alessandro; Azzini, Cristiano; Borgatti, Luca; Marcello, Onofrio; d’Esterre, Christopher; Ceruti, Stefano; Casetta, Ilaria; Lee, Ting-Yim; Fainardi, Enrico

    2016-01-01

    Introduction The capability of CT perfusion (CTP) Alberta Stroke Program Early CT Score (ASPECTS) to predict outcome and identify ischemia severity in acute ischemic stroke (AIS) patients is still questioned. Methods 62 patients with AIS were imaged within 8 hours of symptom onset by non-contrast CT, CT angiography and CTP scans at admission and 24 hours. CTP ASPECTS was calculated on the affected hemisphere using cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) maps by subtracting 1 point for any abnormalities visually detected or measured within multiple cortical circular regions of interest according to previously established thresholds. MTT-CBV ASPECTS was considered as CTP ASPECTS mismatch. Hemorrhagic transformation (HT), recanalization status and reperfusion grade at 24 hours, final infarct volume at 7 days and modified Rankin scale (mRS) at 3 months after onset were recorded. Results Semi-quantitative and quantitative CTP ASPECTS were highly correlated (p<0.00001). CBF, CBV and MTT ASPECTS were higher in patients with no HT and mRS≤2 and inversely associated with final infarct volume and mRS (p values: from p<0.05 to p<0.00001). CTP ASPECTS mismatch was slightly associated with radiological and clinical outcomes (p values: from p<0.05 to p<0.02) only if evaluated quantitatively. A CBV ASPECTS of 9 was the optimal semi-quantitative value for predicting outcome. Conclusions Our findings suggest that visual inspection of CTP ASPECTS recognizes infarct and ischemic absolute values. Semi-quantitative CBV ASPECTS, but not CTP ASPECTS mismatch, represents a strong prognostic indicator, implying that core extent is the main determinant of outcome, irrespective of penumbra size. PMID:26824672

  4. Direct Antimicrobial Susceptibility Testing of Gram-Negative Bacilli in Blood Cultures by an Electrochemical Method

    PubMed Central

    Huang, Ay Huey; Wu, Jiunn Jong; Weng, Yu Mei; Ding, Hwia Cheng; Chang, Tsung Chain

    1998-01-01

    Nonfastidious aerobic gram-negative bacilli (GNB) are commonly isolated from blood cultures. The feasibility of using an electrochemical method for direct antimicrobial susceptibility testing of GNB in positive blood cultures was evaluated. An aliquot (10 μl) of 1:10-diluted positive blood cultures containing GNB was inoculated into the Bactometer module well (bioMérieux Vitek, Hazelwood, Mo.) containing 1 ml of Mueller-Hinton broth supplemented with an antibiotic. Susceptibility tests were performed in a breakpoint broth dilution format, with the results being categorized as resistant, intermediate, or susceptible. Seven antibiotics (ampicillin, cephalothin, gentamicin, amikacin, cefamandole, cefotaxime, and ciprofloxacin) were used in this study, with each agent being tested at the two interpretive breakpoint concentrations. The inoculated modules were incubated at 35°C, and the change in impedance in each well was continuously monitored for 24 h by the Bactometer. The MICs of the seven antibiotics for each blood isolate were also determined by the standardized broth microdilution method. Of 146 positive blood cultures (1,022 microorganism-antibiotic combinations) containing GNB tested by the direct method, the rates of very major, major, and minor errors were 0, 1.1, and 2.5%, respectively. The impedance method was simple; no centrifugation, preincubation, or standardization of the inocula was required, and the susceptibility results were normally available within 3 to 6 h after inoculation. The rapid method may allow proper antimicrobial treatment almost 30 to 40 h before the results of the standard methods are available. PMID:9738038

  5. A model of psychosocial and cultural antecedents of blood pressure control.

    PubMed Central

    Bosworth, Hayden B.; Oddone, Eugene Z.

    2002-01-01

    Hypertension is a major modifiable risk factor for stroke, congestive heart failure, and end-stage renal disease. Hypertension is particularly prevalent and deadly among African Americans. Effective treatment for hypertension has been available for decades, yet only one fourth of all individuals have their blood pressure under control. Despite the potential impact of hypertension, interventions to improve control have had limited success. We present a model of how to understand antecedents of blood pressure control according to three interrelated categories: patient characteristics, social and cultural environment, and medical environment. This theoretical paper was conducted using a literature review and a model to explain psychosocial antecedents of blood pressure control is presented. We conclude that improved understanding of important antecedents of blood pressure control coupled with technological advances, such as tailored interventions, provide clinicians with a tool that may lead to improved blood pressure control. These interventions will require the involvement of clinicians and consideration of sociocultural factors to be successful. PMID:11991336

  6. Successful downstream application of the Paxgene Blood RNA system from small blood samples in paediatric patients for quantitative PCR analysis

    PubMed Central

    Carrol, Enitan D; Salway, Fiona; Pepper, Stuart D; Saunders, Emma; Mankhambo, Limangeni A; Ollier, William E; Hart, C Anthony; Day, Phillip

    2007-01-01

    Background The challenge of gene expression studies is to reliably quantify levels of transcripts, but this is hindered by a number of factors including sample availability, handling and storage. The PAXgene™ Blood RNA System includes a stabilizing additive in a plastic evacuated tube, but requires 2.5 mL blood, which makes routine implementation impractical for paediatric use. The aim of this study was to modify the PAXgene™ Blood RNA System kit protocol for application to small, sick chidren, without compromising RNA integrity, and subsequently to perform quantitative analysis of ICAM and interleukin-6 gene expression. Aliquots of 0.86 mL PAXgene™ reagent were put into microtubes and 0.3 mL whole blood added to maintain the same recommended proportions as in the PAXgene™ evacuated tube system. RNA quality was assessed using the Agilent BioAnalyser 2100 and an in-house TaqMan™ assay which measures GAPDH transcript integrity by determining 3' to 5' ratios. qPCR analysis was performed on an additional panel of 7 housekeeping genes. Three reference genes (HPRT1, YWHAZ and GAPDH) were identified using the GeNORM algorithm, which were subsequently used to normalising target gene expression levels. ICAM-1 and IL-6 gene expression were measured in 87 Malawian children with invasive pneumococcal disease. Results Total RNA yield was between 1,114 and 2,950 ng and the BioAnalyser 2100 demonstrated discernible 18s and 28s bands. The cycle threshold values obtained for the seven housekeeping genes were between 15 and 30 and showed good consistency. Median relative ICAM and IL-6 gene expression were significantly reduced in non-survivors compared to survivors (ICAM: 3.56 vs 4.41, p = 0.04, and IL-6: 2.16 vs 6.73, p = 0.02). Conclusion We have successfully modified the PAXgene™ blood collection system for use in small children and demonstrated preservation of RNA integrity and successful quantitative real-time PCR analysis. PMID:17850649

  7. Mycobacterial blood culture as the only means of diagnosis of disseminated tuberculosis in advanced HIV infection.

    PubMed

    Mathuram, Alice Joan; Michael, Joy Sarojini; Turaka, Vijay Prakash; Jasmine, Sudha; Carey, Ronald; Ramya, I

    2018-04-01

    The diagnosis of disseminated tuberculosis (TB) in advanced HIV infection is often delayed because of difficulty in obtaining suitable specimens for culture. A total of 32 such patients from South India with positive mycobacterial blood cultures were studied over ten years. Almost all (90%) had a febrile illness and the majority (68.7%) had clinical lung involvement, but only 27.3% had positive sputum smears. Liver biopsy yielded a positive diagnosis in only 1/7. Cytopenia was almost universal (96.9%). Bone marrow cultures were, however, positive in 54.8%, of whom one-quarter grew atypical mycobacteria. Mycobacterial blood culture is therefore a useful adjunct test to diagnose TB in advanced HIV.

  8. Quantitative relationship between the octanol/water partition coefficient and the diffusion limitation of the exchange between adipose and blood

    PubMed Central

    2010-01-01

    Background The goal of physiologically based pharmacokinetics (PBPK) is to predict drug kinetics from an understanding of the organ/blood exchange. The standard approach is to assume that the organ is "flow limited" which means that the venous blood leaving the organ equilibrates with the well-stirred tissue compartment. Although this assumption is valid for most solutes, it has been shown to be incorrect for several very highly fat soluble compounds which appear to be "diffusion limited". This paper describes the physical basis of this adipose diffusion limitation and its quantitative dependence on the blood/water (Kbld-wat) and octanol/water (Kow) partition coefficient. Methods Experimental measurements of the time dependent rat blood and adipose concentration following either intravenous or oral input were used to estimate the "apparent" adipose perfusion rate (FA) assuming that the tissue is flow limited. It is shown that the ratio of FA to the anatomic perfusion rate (F) provides a measure of the diffusion limitation. A quantitative relationship between this diffusion limitation and Kbld-wat and Kow is derived. This analysis was applied to previously published data, including the Oberg et. al. measurements of the rat plasma and adipose tissue concentration following an oral dose of a mixture of 13 different polychlorinated biphenyls. Results Solutes become diffusion limited at values of log Kow greater than about 5.6, with the adipose-blood exchange rate reduced by a factor of about 30 for a solute with a log Kow of 7.36. Quantitatively, a plot of FA/F versus Kow is well described assuming an adipose permeability-surface area product (PS) of 750/min. This PS corresponds to a 0.14 micron aqueous layer separating the well-stirred blood from the adipose lipid. This is approximately equal to the thickness of the rat adipose capillary endothelium. Conclusions These results can be used to quantitate the adipose-blood diffusion limitation as a function of Kow. This

  9. Quantitative Analysis of Therapeutic Drugs in Dried Blood Spot Samples by Paper Spray Mass Spectrometry: An Avenue to Therapeutic Drug Monitoring

    NASA Astrophysics Data System (ADS)

    Manicke, Nicholas Edward; Abu-Rabie, Paul; Spooner, Neil; Ouyang, Zheng; Cooks, R. Graham

    2011-09-01

    A method is presented for the direct quantitative analysis of therapeutic drugs from dried blood spot samples by mass spectrometry. The method, paper spray mass spectrometry, generates gas phase ions directly from the blood card paper used to store dried blood samples without the need for complex sample preparation and separation; the entire time for preparation and analysis of blood samples is around 30 s. Limits of detection were investigated for a chemically diverse set of some 15 therapeutic drugs; hydrophobic and weakly basic drugs, such as sunitinib, citalopram, and verapamil, were found to be routinely detectable at approximately 1 ng/mL. Samples were prepared by addition of the drug to whole blood. Drug concentrations were measured quantitatively over several orders of magnitude, with accuracies within 10% of the expected value and relative standard deviation (RSD) of around 10% by prespotting an internal standard solution onto the paper prior to application of the blood sample. We have demonstrated that paper spray mass spectrometry can be used to quantitatively measure drug concentrations over the entire therapeutic range for a wide variety of drugs. The high quality analytical data obtained indicate that the technique may be a viable option for therapeutic drug monitoring.

  10. Quantitative versus semiquantitative MR imaging of cartilage in blood-induced arthritic ankles: preliminary findings.

    PubMed

    Doria, Andrea S; Zhang, Ningning; Lundin, Bjorn; Hilliard, Pamela; Man, Carina; Weiss, Ruth; Detzler, Gary; Blanchette, Victor; Moineddin, Rahim; Eckstein, Felix; Sussman, Marshall S

    2014-05-01

    Recent advances in hemophilia prophylaxis have raised the need for accurate noninvasive methods for assessment of early cartilage damage in maturing joints to guide initiation of prophylaxis. Such methods can either be semiquantitative or quantitative. Whereas semiquantitative scores are less time-consuming to be performed than quantitative methods, they are prone to subjective interpretation. To test the feasibility of a manual segmentation and a quantitative methodology for cross-sectional evaluation of articular cartilage status in growing ankles of children with blood-induced arthritis, as compared with a semiquantitative scoring system and clinical-radiographic constructs. Twelve boys, 11 with hemophilia (A, n = 9; B, n = 2) and 1 with von Willebrand disease (median age: 13; range: 6-17), underwent physical examination and MRI at 1.5 T. Two radiologists semiquantitatively scored the MRIs for cartilage pathology (surface erosions, cartilage loss) with blinding to clinical information. An experienced operator applied a validated quantitative 3-D MRI method to determine the percentage area of denuded bone (dAB) and the cartilage thickness (ThCtAB) in the joints' MRIs. Quantitative and semiquantitative MRI methods and clinical-radiographic constructs (Hemophilia Joint Health Score [HJHS], Pettersson radiograph scores) were compared. Moderate correlations were noted between erosions and dAB (r = 0.62, P = 0.03) in the talus but not in the distal tibia (P > 0.05). Whereas substantial to high correlations (r range: 0.70-0.94, P < 0.05) were observed between erosions, cartilage loss, HJHS and Pettersson scores both at the distal tibia and talus levels, moderate/borderline substantial (r range: 0.55-0.61, P < 0.05) correlations were noted between dAB/ThCtAB and clinical-radiographic constructs. Whereas the semiquantitative method of assessing cartilage status is closely associated with clinical-radiographic scores in cross-sectional studies

  11. Quantitative genetic analysis of the body composition and blood pressure association in two ethnically diverse populations.

    PubMed

    Ghosh, Sudipta; Dosaev, Tasbulat; Prakash, Jai; Livshits, Gregory

    2017-04-01

    The major aim of this study was to conduct comparative quantitative-genetic analysis of the body composition (BCP) and somatotype (STP) variation, as well as their correlations with blood pressure (BP) in two ethnically, culturally and geographically different populations: Santhal, indigenous ethnic group from India and Chuvash, indigenous population from Russia. Correspondently two pedigree-based samples were collected from 1,262 Santhal and1,558 Chuvash individuals, respectively. At the first stage of the study, descriptive statistics and a series of univariate regression analyses were calculated. Finally, multiple and multivariate regression (MMR) analyses, with BP measurements as dependent variables and age, sex, BCP and STP as independent variables were carried out in each sample separately. The significant and independent covariates of BP were identified and used for re-examination in pedigree-based variance decomposition analysis. Despite clear and significant differences between the populations in BCP/STP, both Santhal and Chuvash were found to be predominantly mesomorphic irrespective of their sex. According to MMR analyses variation of BP significantly depended on age and mesomorphic component in both samples, and in addition on sex, ectomorphy and fat mass index in Santhal and on fat free mass index in Chuvash samples, respectively. Additive genetic component contributes to a substantial proportion of blood pressure and body composition variance. Variance component analysis in addition to above mentioned results suggests that additive genetic factors influence BP and BCP/STP associations significantly. © 2017 Wiley Periodicals, Inc.

  12. Quantitative values of blood flow through the human forearm, hand, and finger as functions of temperature

    NASA Technical Reports Server (NTRS)

    Montgomery, L. D.

    1974-01-01

    A literature search was made to obtain values of human forearm, hand and finger blood flow as functions of environmental temperature. The sources used include both government and laboratory reports and the research presented in the open literature. An attempt was made to review many of the more quantitative noninvasive determinations and to collate the results in such a way as to yield blood flow values for each body segment as continuous functions of temperature. A brief review of the various ways used to measure blood flow is included along with an abstract of each work from which data was taken.

  13. Quantitation of dissolved gas content in emulsions and in blood using mass spectrometric detection

    PubMed Central

    Grimley, Everett; Turner, Nicole; Newell, Clayton; Simpkins, Cuthbert; Rodriguez, Juan

    2011-01-01

    Quantitation of dissolved gases in blood or in other biological media is essential for understanding the dynamics of metabolic processes. Current detection techniques, while enabling rapid and convenient assessment of dissolved gases, provide only direct information on the partial pressure of gases dissolved in the aqueous fraction of the fluid. The more relevant quantity known as gas content, which refers to the total amount of the gas in all fractions of the sample, can be inferred from those partial pressures, but only indirectly through mathematical modeling. Here we describe a simple mass spectrometric technique for rapid and direct quantitation of gas content for a wide range of gases. The technique is based on a mass spectrometer detector that continuously monitors gases that are rapidly extracted from samples injected into a purge vessel. The accuracy and sample processing speed of the system is demonstrated with experiments that reproduce within minutes literature values for the solubility of various gases in water. The capability of the technique is further demonstrated through accurate determination of O2 content in a lipid emulsion and in whole blood, using as little as 20 μL of sample. The approach to gas content quantitation described here should greatly expand the range of animals and conditions that may be used in studies of metabolic gas exchange, and facilitate the development of artificial oxygen carriers and resuscitation fluids. PMID:21497566

  14. Blood cell oxidative stress precedes hemolysis in whole blood-liver slice co-cultures of rat, dog, and human tissues

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vickers, Alison E.M., E-mail: vickers_alison@allergan.co; Sinclair, John R.; Fisher, Robyn L.

    A novel in vitro model to investigate time-dependent and concentration-dependent responses in blood cells and hemolytic events is studied for rat, dog, and human tissues. Whole blood is co-cultured with a precision-cut liver slice. Methimazole (MMI) was selected as a reference compound, since metabolism of its imidazole thione moiety is linked with hematologic disorders and hepatotoxicity. An oxidative stress response occurred in all three species, marked by a decline in blood GSH levels by 24 h that progressed, and preceded hemolysis, which occurred at high MMI concentrations in the presence of a liver slice with rat (>= 1000 muM atmore » 48 h) and human tissues (>= 1000 muM at 48 h, >= 750 muM at 72 h) but not dog. Human blood-only cultures exhibited a decline of GSH levels but minimal to no hemolysis. The up-regulation of liver genes for heme degradation (Hmox1 and Prdx1), iron cellular transport (Slc40a1), and GSH synthesis and utilization (mGST1 and Gclc) were early markers of the oxidative stress response. The up-regulation of the Kupffer cell lectin Lgals3 gene expression indicated a response to damaged red blood cells, and Hp (haptoglobin) up-regulation is indicative of increased hemoglobin uptake. Up-regulation of liver IL-6 and IL-8 gene expression suggested an activation of an inflammatory response by liver endothelial cells. In summary, MMI exposure led to an oxidative stress response in blood cells, and an up-regulation of liver genes involved with oxidative stress and heme homeostasis, which was clearly separate and preceded frank hemolysis.« less

  15. Comparison of culture-based, vital stain and PMA-qPCR methods for the quantitative detection of viable hookworm ova.

    PubMed

    Gyawali, P; Sidhu, J P S; Ahmed, W; Jagals, P; Toze, S

    2017-06-01

    Accurate quantitative measurement of viable hookworm ova from environmental samples is the key to controlling hookworm re-infections in the endemic regions. In this study, the accuracy of three quantitative detection methods [culture-based, vital stain and propidium monoazide-quantitative polymerase chain reaction (PMA-qPCR)] was evaluated by enumerating 1,000 ± 50 Ancylostoma caninum ova in the laboratory. The culture-based method was able to quantify an average of 397 ± 59 viable hookworm ova. Similarly, vital stain and PMA-qPCR methods quantified 644 ± 87 and 587 ± 91 viable ova, respectively. The numbers of viable ova estimated by the culture-based method were significantly (P < 0.05) lower than vital stain and PMA-qPCR methods. Therefore, both PMA-qPCR and vital stain methods appear to be suitable for the quantitative detection of viable hookworm ova. However, PMA-qPCR would be preferable over the vital stain method in scenarios where ova speciation is needed.

  16. Evaluation of the Verigene Gram-Positive Blood Culture Nucleic Acid Test for Rapid Detection of Bacteria and Resistance Determinants

    PubMed Central

    Wojewoda, Christina M.; Sercia, Linda; Navas, Maria; Tuohy, Marion; Wilson, Deborah; Hall, Geraldine S.; Procop, Gary W.

    2013-01-01

    Rapid identification of pathogens from blood cultures can decrease lengths of stay and improve patient outcomes. We evaluated the accuracy of the Verigene Gram-positive blood culture (BC-GP) nucleic acid test for investigational use only (Nanosphere, Inc., Northbrook, IL) for the identification of Gram-positive bacteria from blood cultures. The detection of resistance genes (mecA in Staphylococcus aureus and Staphylococcus epidermidis and vanA or vanB in Enterococcus faecium and Enterococcus faecalis) by the BC-GP assay also was assessed. A total of 186 positive blood cultures (in BacT/Alert FA bottles) with Gram-positive cocci observed with Gram staining were analyzed using the BC-GP assay. The BC-GP results were compared with the identification and susceptibility profiles obtained with routine methods in the clinical laboratory. Discordant results were arbitrated with additional biochemical, cefoxitin disk, and repeat BC-GP testing. The initial BC-GP organism identification was concordant with routine method results for 94.6% of the blood cultures. Only 40% of the Streptococcus pneumoniae identifications were correct. The detection of the mecA gene for 69 blood cultures with only S. aureus or S. epidermidis was concordant with susceptibility testing results. For 3 of 6 cultures with multiple Staphylococcus spp., mecA detection was reported but was correlated with oxacillin resistance in a species other than S. aureus or S. epidermidis. The detection of vanA agreed with susceptibility testing results for 45 of 46 cultures with E. faecalis or E. faecium. Comparison of the mean times to results for each organism group showed that BC-GP results were available 31 to 42 h earlier than phenotypic identifications and 41 to 50 h earlier than susceptibility results. PMID:23596240

  17. Evaluation of the Verigene Gram-positive blood culture nucleic acid test for rapid detection of bacteria and resistance determinants.

    PubMed

    Wojewoda, Christina M; Sercia, Linda; Navas, Maria; Tuohy, Marion; Wilson, Deborah; Hall, Geraldine S; Procop, Gary W; Richter, Sandra S

    2013-07-01

    Rapid identification of pathogens from blood cultures can decrease lengths of stay and improve patient outcomes. We evaluated the accuracy of the Verigene Gram-positive blood culture (BC-GP) nucleic acid test for investigational use only (Nanosphere, Inc., Northbrook, IL) for the identification of Gram-positive bacteria from blood cultures. The detection of resistance genes (mecA in Staphylococcus aureus and Staphylococcus epidermidis and vanA or vanB in Enterococcus faecium and Enterococcus faecalis) by the BC-GP assay also was assessed. A total of 186 positive blood cultures (in BacT/Alert FA bottles) with Gram-positive cocci observed with Gram staining were analyzed using the BC-GP assay. The BC-GP results were compared with the identification and susceptibility profiles obtained with routine methods in the clinical laboratory. Discordant results were arbitrated with additional biochemical, cefoxitin disk, and repeat BC-GP testing. The initial BC-GP organism identification was concordant with routine method results for 94.6% of the blood cultures. Only 40% of the Streptococcus pneumoniae identifications were correct. The detection of the mecA gene for 69 blood cultures with only S. aureus or S. epidermidis was concordant with susceptibility testing results. For 3 of 6 cultures with multiple Staphylococcus spp., mecA detection was reported but was correlated with oxacillin resistance in a species other than S. aureus or S. epidermidis. The detection of vanA agreed with susceptibility testing results for 45 of 46 cultures with E. faecalis or E. faecium. Comparison of the mean times to results for each organism group showed that BC-GP results were available 31 to 42 h earlier than phenotypic identifications and 41 to 50 h earlier than susceptibility results.

  18. Blood culture positive Nocardia asteroides infection: a case report.

    PubMed

    Höpler, Wolfgang; Laferl, Hermann; Szell, Marton; Pongratz, Peter; Brandl, Irmgard; Tucek, Gerhard; Wenisch, Christoph

    2013-01-01

    We report a case of nocardiosis in a patient with several risk factors for this rare infection. Radiologically, the patient's multiple lung abscesses were misinterpreted as pulmonary metastases. Diagnosis was finally reached by the growth of Nocardia asteroides in two different blood culture sets. Nocardia bacteraemia is a rare clinical event. Despite initiation of an effective antibiotic therapy, the patient died. Autopsy revealed disseminated nocardial abscesses in the lungs, the kidneys and the brain.

  19. Time-to-detection of bacteria and yeast with the BACTEC FX versus BacT/Alert Virtuo blood culture systems.

    PubMed

    Somily, Ali Mohammed; Habib, Hanan Ahmed; Torchyan, Armen Albert; Sayyed, Samina B; Absar, Muhammed; Al-Aqeel, Rima; Binkhamis, A Khalifa

    2018-01-01

    Bloodstream infections are associated with high rates of morbidity and mortality. Rapid detection of bloodstream infections is important in achieving better patient outcomes. Compare the time-to-detection (TTD) of the new BacT/Alert Virtuo and the BACTEC FX automated blood culture systems. Prospective simulated comparison of two instruments using seeded samples. Medical microbiology laboratory. Blood culture bottles were seeded in triplicate with each of the standard ATCC strains of aerobes, anaerobes and yeast. TTD was calculated as the length of time from the beginning of culture incubation to the detection of bacterial growth. TTD for the various tested organisms on the two microbial detection systems. The 99 bottles of seeded blood cultures incubated in each of the blood culture systems included 21 anaerobic, 39 aerobic and 39 pediatric bottles. The BacT/Alert Virtuo system exhibited significantly shorter TTD for 72.7 % of the tested organisms compared to BACTEC FX system with a median difference in mean TTD of 2.1 hours (interquartile range: 1.5-3.5 hours). The BACTEC FX system was faster in 15.2% (5/33) of microorganisms, with a median difference in mean TTD of 25.9 hours (IQR: 9.1-29.2 hours). TTD was significantly shorter for most of the microorganisms tested on the new BacT/Alert Virtuo system compared to the BACTEC FX system. Use of simulated cultures to assess TTD may not precisely represent clinical blood cultures. None.

  20. CULTURES FROM THE BLOOD In SEPTICÆMIA, PNEUMONIA, MENINGITIS AND CHRONIC DISEASES

    PubMed Central

    White, Franklin Warren

    1899-01-01

    Our conclusions from the literature and our own experiments may be summarized as follows: I. Blood for bacteriological examination during life should be taken directly from the veins and in considerable quantity. II. Resorption of toxines is the most important feature in cases of sepsis; pyogenie bacteria invade the general circulation in a rather small proportion even of severe eases, and, as a rule, late in the course of the disease. III. A general infection by the pnenmococcus can be demonstrated occasionally in the late stages of acute lobar pneumonia. IV. The value of blood cultures as a means of diagnosis in obscure cases of sepsis is limited by the fact that invasion of the blood by the specific organism cannot be demonstrated during life in the majority of cases. Positive cultures are very valuable; negative cultures do not exclude local septic infections. V. The detection of specific bacteria in the blood of cases of sepsis and of pneumonia gives a very unfavorable prognosis in most cases. VI. General terminal infections with pyogenic cocci occasionally occur as an immediate cause of death in chronic disease. Local infections processes play this part more frequently. VII. As far as our experiments have shown, invasion of the blood by bacteria during the death agony, with subsequent distribution of the genus to the organs by the circulation, is a rather uncommon occurrence. VIII. Owing to the relative infrequency of agonal invasion, we believe that in the majority of cases where the autopsy is performed promptly after death, the bacteria which are found in the organs succeeded in reaching these organs previously to the death agony, and are associated with the course of the disease. IX. The presence of bacteria in the organs of late autopsies is due in many cases to post-mortem extension from one organ to another, and in some cases to the post-mortem growth of small numbers of genus which were distributed to the organs by means of the circulation. PMID

  1. Comparison between culture and a multiplex quantitative real-time polymerase chain reaction assay detecting Ureaplasma urealyticum and U. parvum.

    PubMed

    Frølund, Maria; Björnelius, Eva; Lidbrink, Peter; Ahrens, Peter; Jensen, Jørgen Skov

    2014-01-01

    A novel multiplex quantitative real-time polymerase chain reaction (qPCR) for simultaneous detection of U. urealyticum and U. parvum was developed and compared with quantitative culture in Shepard's 10 C medium for ureaplasmas in urethral swabs from 129 men and 66 women, and cervical swabs from 61 women. Using culture as the gold standard, the sensitivity of the qPCR was 96% and 95% for female urethral and cervical swabs, respectively. In male urethral swabs the sensitivity was 89%. The corresponding specificities were 100%, 87% and 99%. The qPCR showed a linear increasing DNA copy number with increasing colour-changing units. Although slightly less sensitive than culture, this multiplex qPCR assay detecting U. urealyticum and U. parvum constitutes a simple and fast alternative to the traditional methods for identification of ureaplasmas and allows simultaneous species differentiation and quantitation in clinical samples. Furthermore, specimens overgrown by other bacteria using the culture method can be evaluated in the qPCR.

  2. Quantitative Analysis of Rat Dorsal Root Ganglion Neurons Cultured on Microelectrode Arrays Based on Fluorescence Microscopy Image Processing.

    PubMed

    Mari, João Fernando; Saito, José Hiroki; Neves, Amanda Ferreira; Lotufo, Celina Monteiro da Cruz; Destro-Filho, João-Batista; Nicoletti, Maria do Carmo

    2015-12-01

    Microelectrode Arrays (MEA) are devices for long term electrophysiological recording of extracellular spontaneous or evocated activities on in vitro neuron culture. This work proposes and develops a framework for quantitative and morphological analysis of neuron cultures on MEAs, by processing their corresponding images, acquired by fluorescence microscopy. The neurons are segmented from the fluorescence channel images using a combination of segmentation by thresholding, watershed transform, and object classification. The positioning of microelectrodes is obtained from the transmitted light channel images using the circular Hough transform. The proposed method was applied to images of dissociated culture of rat dorsal root ganglion (DRG) neuronal cells. The morphological and topological quantitative analysis carried out produced information regarding the state of culture, such as population count, neuron-to-neuron and neuron-to-microelectrode distances, soma morphologies, neuron sizes, neuron and microelectrode spatial distributions. Most of the analysis of microscopy images taken from neuronal cultures on MEA only consider simple qualitative analysis. Also, the proposed framework aims to standardize the image processing and to compute quantitative useful measures for integrated image-signal studies and further computational simulations. As results show, the implemented microelectrode identification method is robust and so are the implemented neuron segmentation and classification one (with a correct segmentation rate up to 84%). The quantitative information retrieved by the method is highly relevant to assist the integrated signal-image study of recorded electrophysiological signals as well as the physical aspects of the neuron culture on MEA. Although the experiments deal with DRG cell images, cortical and hippocampal cell images could also be processed with small adjustments in the image processing parameter estimation.

  3. Cultural differences in human brain activity: a quantitative meta-analysis.

    PubMed

    Han, Shihui; Ma, Yina

    2014-10-01

    Psychologists have been trying to understand differences in cognition and behavior between East Asian and Western cultures within a single cognitive framework such as holistic versus analytic or interdependent versus independent processes. However, it remains unclear whether cultural differences in multiple psychological processes correspond to the same or different neural networks. We conducted a quantitative meta-analysis of 35 functional MRI studies to examine cultural differences in brain activity engaged in social and non-social processes. We showed that social cognitive processes are characterized by stronger activity in the dorsal medial prefrontal cortex, lateral frontal cortex and temporoparietal junction in East Asians but stronger activity in the anterior cingulate, ventral medial prefrontal cortex and bilateral insula in Westerners. Social affective processes are associated with stronger activity in the right dorsal lateral frontal cortex in East Asians but greater activity in the left insula and right temporal pole in Westerners. Non-social processes induce stronger activity in the left inferior parietal cortex, left middle occipital and left superior parietal cortex in East Asians but greater activations in the right lingual gyrus, right inferior parietal cortex and precuneus in Westerners. The results suggest that cultural differences in social and non-social processes are mediated by distinct neural networks. Moreover, East Asian cultures are associated with increased neural activity in the brain regions related to inference of others' mind and emotion regulation whereas Western cultures are associated with enhanced neural activity in the brain areas related to self-relevance encoding and emotional responses during social cognitive/affective processes. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. The efficacy of 2% chlorhexidine gluconate in 70% alcohol compared with 10% povidone iodine in reducing blood culture contamination in pediatric patients.

    PubMed

    Tangsathapompong, Auchara; Banjongmanee, Pornumpa; Unrit, Kengkaj; Sritipsukho, Paskorn; Mungkornkaew, Narisara; Sajak, Sirinporn

    2014-08-01

    Blood culture is the gold standard for diagnosis of septicemia. However; false-positive blood cultures are associated with increased health care costs due to unnecessary treatment. To evaluate the efficacy of 2% chlorhexidine gluconate in 70% alcohol compared with 10% povidone iodine in reducing blood culture contamination inpediatricpatients. This is a prospective study of pediatric patients who were admitted at a tertiary-care hospital. Pediatric patients who neededpercutaneous blood cultures were recruitedfrom two general pediatric wards and the pediatric intensive care unit. The authors used 10% povidone iodine as an antiseptic in odd months and 2% chlorhexidine gluconate in 70% alcohol as an antiseptic in even months in obtaining the blood culture samples. There were 1,269 blood culture specimens taken from 821 patients. 654 specimens used 10%povidone iodine as an antiseptic and 619 specimens used 2% chlorhexidine gluconate in 70% alcohol as an antiseptic. The 10% povidone iodine group and the 2% chlorhexidine gluconate in 70% alcohol group had the risk of blood culture contamination of 3.21% (95%CI: 2.00%-4.87%) and 2.28% (95% CI: 1.25%-3.79%) respectively. The risk difference ofblood culture contamination was 0.93% (95% confidence interval: 0. 86-2.72%) with p = 0.31. The most common contamination organism was Coagulase negative staphylococci (68.57%). No adverse skin reactions were observed in both antiseptic solutions groups. Use of2% chlorhexidine gluconate in 70% alcohol as an antiseptic seems to reduce the risk of blood culture contamination compared to use of 10% povidone iodine. In addition, neither of the antiseptic solutions resulted in adverse skin reactions.

  5. Simple Sample Preparation Method for Direct Microbial Identification and Susceptibility Testing From Positive Blood Cultures.

    PubMed

    Pan, Hong-Wei; Li, Wei; Li, Rong-Guo; Li, Yong; Zhang, Yi; Sun, En-Hua

    2018-01-01

    Rapid identification and determination of the antibiotic susceptibility profiles of the infectious agents in patients with bloodstream infections are critical steps in choosing an effective targeted antibiotic for treatment. However, there has been minimal effort focused on developing combined methods for the simultaneous direct identification and antibiotic susceptibility determination of bacteria in positive blood cultures. In this study, we constructed a lysis-centrifugation-wash procedure to prepare a bacterial pellet from positive blood cultures, which can be used directly for identification by matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOF MS) and antibiotic susceptibility testing by the Vitek 2 system. The method was evaluated using a total of 129 clinical bacteria-positive blood cultures. The whole sample preparation process could be completed in <15 min. The correct rate of direct MALDI-TOF MS identification was 96.49% for gram-negative bacteria and 97.22% for gram-positive bacteria. Vitek 2 antimicrobial susceptibility testing of gram-negative bacteria showed an agreement rate of antimicrobial categories of 96.89% with a minor error, major error, and very major error rate of 2.63, 0.24, and 0.24%, respectively. Category agreement of antimicrobials against gram-positive bacteria was 92.81%, with a minor error, major error, and very major error rate of 4.51, 1.22, and 1.46%, respectively. These results indicated that our direct antibiotic susceptibility analysis method worked well compared to the conventional culture-dependent laboratory method. Overall, this fast, easy, and accurate method can facilitate the direct identification and antibiotic susceptibility testing of bacteria in positive blood cultures.

  6. Evaluation of the Nanosphere Verigene Gram-Positive Blood Culture Assay with the VersaTREK Blood Culture System and Assessment of Possible Impact on Selected Patients

    PubMed Central

    Beal, Stacy G.; Ciurca, Jane; Smith, Geremy; John, Jeffrey; Lee, Francesca; Doern, Christopher D.

    2013-01-01

    The Verigene Gram-positive blood culture (BC-GP) assay (Nanosphere, Northbrook, IL) is a molecular method for the rapid identification of Gram-positive organisms and resistance markers directly from blood culture bottles. A total of 148 VersaTREK REDOX 1 40-ml aerobic bottles demonstrating Gram-positive bacteria were tested. Results were compared with those from conventional biochemical and matrix-assisted laser desorption ionization–time of flight (MALDI-TOF) identifications. We obtained isolates of methicillin-resistant Staphylococcus aureus (MRSA) (24), methicillin-susceptible Staphylococcus aureus (MSSA) (14), methicillin-resistant Staphylococcus epidermidis (MRSE) (17), methicillin-susceptible Staphylococcus epidermidis (MSSE) (9), other coagulase-negative staphylococci (19), Streptococcus salivarius (5), Streptococcus parasanguinis (2), Streptococcus sanguinis (1), Streptococcus cristatus (1), the Streptococcus bovis group (5), Streptococcus agalactiae (9), the Streptococcus anginosus group (1), Streptococcus pneumoniae (6), vancomycin-resistant Enterococcus faecium (VRE FCM) (16), vancomycin-susceptible Enterococcus faecalis (3), Aerococcus viridans (2), Bacillus (6), Corynebacterium (8), Lactobacillus (2), Micrococcus (2), Neisseria mucosa (1), Escherichia coli (3), Candida tropicalis (1), Propionibacterium (1), and Rothia (1). Overall agreement with the culture results was 95%. A total of 137 of 138 (99%) monomicrobial cultures were concordant. We tested 9 polymicrobial samples and found 33% agreement. A chart review of 31 patients with MRSA, MSSA, or VRE demonstrated that the Nanosphere BC-GP assay might have led to more appropriate antibiotic selection for these patients an average of 42 h earlier. Additionally, contact isolation could have been initiated an average of 37 h earlier for patients with MRSA or VRE. The BC-GP assay may have a positive impact on patient care, health care costs, and antibiotic stewardship. PMID:24048531

  7. Is the Presence of Actinomyces spp. in Blood Culture Always Significant?

    PubMed Central

    Nic-Fhogartaigh, Caoimhe; Millar, Michael

    2016-01-01

    The isolation of Actinomyces spp. from sterile clinical samples is traditionally regarded as significant. We reviewed the demographic characteristics, clinical risk factors, and outcomes of patients with Actinomyces spp. isolated from blood cultures in our NHS Trust and found that this is not necessarily the case. PMID:26818678

  8. Western Culture in Japanese Film: Kurosawa's "Throne of Blood" and "Ran."

    ERIC Educational Resources Information Center

    Kane, Peter E.

    Akira Kurosawa, the most popular Asian film maker with audiences in the United States, has found in William Shakespeare's plays themes and plots that resonate within Japanese culture. While the translations of "Macbeth" into "Throne of Blood" and "King Lear" into "Ran" are quite direct and literal with only…

  9. Prevalence of ESBL-producing Enterobacteriaceae isolated from blood cultures in Mali.

    PubMed

    Sangare, Samba Adama; Maiga, Almoustapha Issiaka; Guindo, Ibrehima; Maiga, Aminata; Camara, Namory; Dicko, Oumar Agaly; Diallo, Souleymane; Bougoudogo, Flabou; Armand-Lefevre, Laurence; Andremont, Antoine; Maiga, Ibrahim Izetiegouma

    2016-10-31

    The increasing frequency of extended-spectrum beta-lactamase (ESBL)-producing Enterobacteriaceae is becoming a serious public health concern. This study sought to determine ESBL frequency in Enterobacteriaceae isolated from patients' blood cultures in two university teaching hospitals of Bamako, Mali. During a three-month period, the presence of Enterobacteriaceae from blood cultures of patients admitted to the university teaching hospitals of Bamako was evaluated. The microbial identifications were initially performed with an API 20E gallery and VITEK2 locally in Mali, and then confirmation in France was performed with a mass spectrometry MALDI-TOF in the bacteriology laboratory of the university teaching hospital of Bichat. Antibiotic susceptibility profiles were determined by the diffusion method as recommended by the European Committee on Antimicrobial Susceptibility Testing (EUCAST). The isolated species were K. pneumoniae (14/40; 35.0%), E. coli (11/40; 27.5%), and E. cloacae (9/40; 22.5%). Of the strains isolated, 21/34 (61.8%) had an ESBL phenotype, including 10/14 (71.4%) K. pneumoniae, 8/11 (72.7%) E. coli, and 3/9 (33.3%) E. cloacae. Resistances associated with ESBL strains of K. pneumoniae, E. coli, and E. cloacae were as follows: gentamicin (10/10, 100%; 6/8, 75%; 2/3, 67%, respectively), amikacin (2/10, 20%; 0/8, 0%; 0/3, 0%, respectively), ofloxacin (8/10, 80%; 7/8, 87%; 3/3, 100%, respectively), and cotrimoxazole (10/10, 100%; 6/8, 75%; 3/3, 100%, respectively). Almost two-thirds (61.8%) of Enterobacteriaceae isolated from our blood cultures were ESBL producers. Only susceptibilities to carbapenems and to amikacin were fully conserved within the strains.

  10. Acceleration of Antimicrobial Susceptibility Testing of Positive Blood Cultures by Inoculation of Vitek 2 Cards with Briefly Incubated Solid Medium Cultures

    PubMed Central

    Idelevich, Evgeny A.; Schüle, Isabel; Grünastel, Barbara; Wüllenweber, Jörg; Peters, Georg

    2014-01-01

    Briefly incubated agar cultures from positive blood cultures were used for antimicrobial susceptibility testing (AST) by Vitek 2. The cultivation time until inoculation was 3.8 h for Gram-positive cocci and 2.4 h for Gram-negative rods. The error rates were low, providing early and reliable AST without additional time or cost expenditure. PMID:25165084

  11. Knowledge of Good Blood Culture Sampling Practice among Healthcare Staffs in An Emergency Department - Are We Getting It Right?

    PubMed

    Chew, K S; Mohd Hashairi, F; Jusoh, A F; Aziz, A A; Nik Hisamuddin, N A R; Siti Asma, H

    2013-08-01

    Although a vital test, blood culture is often plagued with the problem of contamination and false results, especially in a chaotic emergency department setting. The objectives of this pilot study is to find out the level of understanding among healthcare staffs in emergency department, Hospital Universiti Sains Malaysia (HUSM) regarding good blood culture sampling practice. All healthcare staffs in emergency department, HUSM who consented to this study were given a set of selfadministered anonymous questionnaire to fill. More than half (53.1%) of the 64 participants are emergency medicine residents. Majority of them (75%) have been working in the emergency medicine, HUSM for more than 2 years. More than half of them were able to answer correctly the amount of blood volume needed for culture in adult and pediatric patients. When asked what are the factors required to improve the true yield as well as to reduce the risk of culture contamination, the four commonest answers given were observing proper aseptic technique during blood sampling, donning sterile glove, proper hand scrubbing as well as ensuring the sterility of the equipments. This study suggests that there is a lack of proper knowledge of good blood culture sampling practice among our healthcare staffs in emergency department.

  12. Molecular Detection of Streptococcus pneumoniae on Dried Blood Spots from Febrile Nigerian Children Compared to Culture

    PubMed Central

    Iroh Tam, Pui-Ying; Hernandez-Alvarado, Nelmary; Schleiss, Mark R.; Hassan-Hanga, Fatimah; Onuchukwu, Chuma; Umoru, Dominic; Obaro, Stephen K.

    2016-01-01

    Background Nigeria has one of the highest burdens of pneumococcal disease in the world, but accurate surveillance is lacking. Molecular detection of infectious pathogens in dried blood spots (DBS) is an ideal method for surveillance of infections in resource-limited settings because of its low cost, minimal blood volumes involved, and ease of storage at ambient temperature. Our study aim was to evaluate a Streptococcus pneumoniae real-time polymerase chain reaction (rt-PCR) assay on DBS from febrile Nigerian children on Whatman 903 and FTA filter papers, compared to the gold standard of culture. Methods Between September 2011 to May 2015, blood was collected from children 5 years of age or under who presented to six hospital study sites throughout northern and central Nigeria with febrile illness, and inoculated into blood culture bottles or spotted onto Whatman 903 or FTA filter paper. Culture and rt-PCR were performed on all samples. Results A total of 537 DBS specimens from 535 children were included in the study, of which 15 were culture-positive for S. pneumoniae. The rt-PCR assay detected S. pneumoniae in 12 DBS specimens (2.2%). One positive rt-PCR result was identified in a culture-negative specimen from a high-risk subject, and two positive rt-PCR results were negative on repeat testing. Six culture-confirmed cases of S. pneumoniae bacteremia were missed. Compared to culture, the overall sensitivities of Whatman 903 and FTA DBS for detection of S. pneumoniae were 57.1% (95% CI 18.4–90.1%) and 62.5% (95% CI 24.5–91.5%), respectively. Nonspecific amplification was noted in an additional 22 DBS (4.1%). Among these, six were positive for a non-S. pneumoniae pathogen on culture. Conclusions Rt-PCR was able to detect S. pneumoniae from clinical DBS specimens, including from a culture-negative specimen. Our findings show promise of this approach as a surveillance diagnostic, but also raise important cautionary questions. Several DBS specimens were detected as

  13. Molecular Detection of Streptococcus pneumoniae on Dried Blood Spots from Febrile Nigerian Children Compared to Culture.

    PubMed

    Iroh Tam, Pui-Ying; Hernandez-Alvarado, Nelmary; Schleiss, Mark R; Hassan-Hanga, Fatimah; Onuchukwu, Chuma; Umoru, Dominic; Obaro, Stephen K

    2016-01-01

    Nigeria has one of the highest burdens of pneumococcal disease in the world, but accurate surveillance is lacking. Molecular detection of infectious pathogens in dried blood spots (DBS) is an ideal method for surveillance of infections in resource-limited settings because of its low cost, minimal blood volumes involved, and ease of storage at ambient temperature. Our study aim was to evaluate a Streptococcus pneumoniae real-time polymerase chain reaction (rt-PCR) assay on DBS from febrile Nigerian children on Whatman 903 and FTA filter papers, compared to the gold standard of culture. Between September 2011 to May 2015, blood was collected from children 5 years of age or under who presented to six hospital study sites throughout northern and central Nigeria with febrile illness, and inoculated into blood culture bottles or spotted onto Whatman 903 or FTA filter paper. Culture and rt-PCR were performed on all samples. A total of 537 DBS specimens from 535 children were included in the study, of which 15 were culture-positive for S. pneumoniae. The rt-PCR assay detected S. pneumoniae in 12 DBS specimens (2.2%). One positive rt-PCR result was identified in a culture-negative specimen from a high-risk subject, and two positive rt-PCR results were negative on repeat testing. Six culture-confirmed cases of S. pneumoniae bacteremia were missed. Compared to culture, the overall sensitivities of Whatman 903 and FTA DBS for detection of S. pneumoniae were 57.1% (95% CI 18.4-90.1%) and 62.5% (95% CI 24.5-91.5%), respectively. Nonspecific amplification was noted in an additional 22 DBS (4.1%). Among these, six were positive for a non-S. pneumoniae pathogen on culture. Rt-PCR was able to detect S. pneumoniae from clinical DBS specimens, including from a culture-negative specimen. Our findings show promise of this approach as a surveillance diagnostic, but also raise important cautionary questions. Several DBS specimens were detected as S. pneumoniae by rt-PCR despite growth of

  14. Quantitative photothermal phase imaging of red blood cells using digital holographic photothermal microscope.

    PubMed

    Vasudevan, Srivathsan; Chen, George C K; Lin, Zhiping; Ng, Beng Koon

    2015-05-10

    Photothermal microscopy (PTM), a noninvasive pump-probe high-resolution microscopy, has been applied as a bioimaging tool in many biomedical studies. PTM utilizes a conventional phase contrast microscope to obtain highly resolved photothermal images. However, phase information cannot be extracted from these photothermal images, as they are not quantitative. Moreover, the problem of halos inherent in conventional phase contrast microscopy needs to be tackled. Hence, a digital holographic photothermal microscopy technique is proposed as a solution to obtain quantitative phase images. The proposed technique is demonstrated by extracting phase values of red blood cells from their photothermal images. These phase values can potentially be used to determine the temperature distribution of the photothermal images, which is an important study in live cell monitoring applications.

  15. Cost analysis of strategies to reduce blood culture contamination in the emergency department: sterile collection kits and phlebotomy teams.

    PubMed

    Self, Wesley H; Talbot, Thomas R; Paul, Barbara R; Collins, Sean P; Ward, Michael J

    2014-08-01

    Blood culture collection practices that reduce contamination, such as sterile blood culture collection kits and phlebotomy teams, increase up-front costs for collecting cultures but may lead to net savings by eliminating downstream costs associated with contamination. The study objective was to compare overall hospital costs associated with 3 collection strategies: usual care, sterile kits, and phlebotomy teams. Cost analysis. This analysis was conducted from the perspective of a hospital leadership team selecting a blood culture collection strategy for an adult emergency department (ED) with 8,000 cultures drawn annually. Total hospital costs associated with 3 strategies were compared: (1) usual care, with nurses collecting cultures without a standardized protocol; (2) sterile kits, with nurses using a dedicated sterile collection kit; and (3) phlebotomy teams, with cultures collected by laboratory-based phlebotomists. In the base case, contamination rates associated with usual care, sterile kits, and phlebotomy teams were assumed to be 4.34%, 1.68%, and 1.10%, respectively. Total hospital costs included costs of collecting cultures and hospitalization costs according to culture results (negative, true positive, and contaminated). Compared with usual care, annual net savings using the sterile kit and phlebotomy team strategies were $483,219 and $288,980, respectively. Both strategies remained less costly than usual care across a broad range of sensitivity analyses. EDs with high blood culture contamination rates should strongly consider evidence-based strategies to reduce contamination. In addition to improving quality, implementing a sterile collection kit or phlebotomy team strategy is likely to result in net cost savings.

  16. Susceptibility Testing by Polymerase Chain Reaction DNA Quantitation: A Method to Measure Drug Resistance of Human Immunodeficiency Virus Type 1 Isolates

    NASA Astrophysics Data System (ADS)

    Eron, Joseph J.; Gorczyca, Paul; Kaplan, Joan C.; D'Aquila, Richard T.

    1992-04-01

    Polymerase chain reaction (PCR) DNA quantitation (PDQ) susceptibility testing rapidly and directly measures nucleoside sensitivity of human immunodeficiency virus type 1 (HIV-1) isolates. PCR is used to quantitate the amount of HIV-1 DNA synthesized after in vitro infection of peripheral blood mononuclear cells. The relative amounts of HIV-1 DNA in cell lysates from cultures maintained at different drug concentrations reflect drug inhibition of virus replication. The results of PDQ susceptibility testing of 2- or 3-day cultures are supported by assays measuring HIV-1 p24 antigen production in supernatants of 7- or 10-day cultures. DNA sequence analyses to identify mutations in the reverse transcriptase gene that cause resistance to 3'-azido-3'-deoxythymidine also support the PDQ results. With the PDQ method, both infectivity titration and susceptibility testing can be performed on supernatants from primary cultures of peripheral blood mononuclear cells. PDQ susceptibility testing should facilitate epidemiologic studies of the clinical significance of drug-resistant HIV-1 isolates.

  17. Direct identification of bacteria in positive blood culture bottles by matrix-assisted laser desorption ionisation time-of-flight mass spectrometry.

    PubMed

    La Scola, Bernard; Raoult, Didier

    2009-11-25

    With long delays observed between sampling and availability of results, the usefulness of blood cultures in the context of emergency infectious diseases has recently been questioned. Among methods that allow quicker bacterial identification from growing colonies, matrix-assisted laser desorption ionisation time-of-flight (MALDI-TOF) mass spectrometry was demonstrated to accurately identify bacteria routinely isolated in a clinical biology laboratory. In order to speed up the identification process, in the present work we attempted bacterial identification directly from blood culture bottles detected positive by the automate. We prospectively analysed routine MALDI-TOF identification of bacteria detected in blood culture by two different protocols involving successive centrifugations and then lysis by trifluoroacetic acid or formic acid. Of the 562 blood culture broths detected as positive by the automate and containing one bacterial species, 370 (66%) were correctly identified. Changing the protocol from trifluoroacetic acid to formic acid improved identification of Staphylococci, and overall correct identification increased from 59% to 76%. Lack of identification was observed mostly with viridans streptococci, and only one false positive was observed. In the 22 positive blood culture broths that contained two or more different species, only one of the species was identified in 18 samples, no species were identified in two samples and false species identifications were obtained in two cases. The positive predictive value of bacterial identification using this procedure was 99.2%. MALDI-TOF MS is an efficient method for direct routine identification of bacterial isolates in blood culture, with the exception of polymicrobial samples and viridans streptococci. It may replace routine identification performed on colonies, provided improvement for the specificity of blood culture broths growing viridans streptococci is obtained in the near future.

  18. Unique blood culture for diagnosis of bloodstream infections in emergency departments: a prospective multicentre study.

    PubMed

    Dargère, S; Parienti, J-J; Roupie, E; Gancel, P-E; Wiel, E; Smaiti, N; Loiez, C; Joly, L-M; Lemée, L; Pestel-Caron, M; du Cheyron, D; Verdon, R; Leclercq, R; Cattoir, V

    2014-11-01

    Detection of microorganisms by blood cultures (BCs) is essential in managing patients with bacteraemia. Rather than the number of punctures, the volume of blood drawn is considered paramount in efficient and reliable detection of microorganisms. We performed a 1-year prospective multicentre study in adult emergency departments of three French university hospitals comparing two methods for BCs: a unique blood culture (UBC) collecting a large volume of blood (40 mL) and the standard method of multiple blood cultures (MBC). The performances of both methods for bacterial contamination and efficient microbial detection were compared, each patient serving as his own control. Amongst the 2314 patients included, three hundred were positive for pathogens (n=245) or contaminants (n=55). Out of the 245 patients, 11 were positive for pathogens by UBC but negative by MBC and seven negative by UBC but positive by MBC (p 0.480). In the subgroup of 137 patients with only two BCs, UBC was superior to MBC (p 0.044). Seven and 17 patients had contaminated BCs by UBC and MBC only, respectively (p 0.062). Considering the sums of pathogens missed and contaminants, UBC significantly outperformed MBC (p 0.045). Considering the complete picture of cost savings, efficient detection of microorganisms and decrease in contaminations, UBC offers an interesting alternative to MBC. © 2014 The Authors Clinical Microbiology and Infection © 2014 European Society of Clinical Microbiology and Infectious Diseases.

  19. Quantitation of dissolved gas content in emulsions and in blood using mass spectrometric detection.

    PubMed

    Grimley, Everett; Turner, Nicole; Newell, Clayton; Simpkins, Cuthbert; Rodriguez, Juan

    2011-06-01

    Quantitation of dissolved gases in blood or in other biological media is essential for understanding the dynamics of metabolic processes. Current detection techniques, while enabling rapid and convenient assessment of dissolved gases, provide only direct information on the partial pressure of gases dissolved in the aqueous fraction of the fluid. The more relevant quantity known as gas content, which refers to the total amount of the gas in all fractions of the sample, can be inferred from those partial pressures, but only indirectly through mathematical modeling. Here we describe a simple mass spectrometric technique for rapid and direct quantitation of gas content for a wide range of gases. The technique is based on a mass spectrometer detector that continuously monitors gases that are rapidly extracted from samples injected into a purge vessel. The accuracy and sample processing speed of the system is demonstrated with experiments that reproduce within minutes literature values for the solubility of various gases in water. The capability of the technique is further demonstrated through accurate determination of O(2) content in a lipid emulsion and in whole blood, using as little as 20 μL of sample. The approach to gas content quantitation described here should greatly expand the range of animals and conditions that may be used in studies of metabolic gas exchange, and facilitate the development of artificial oxygen carriers and resuscitation fluids. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. An appropriately performed conventional blood culture can facilitate choice of therapy in resource-constrained settings-comparison with BACTEC 9050.

    PubMed

    Surase, P V; Nataraj, G; Pattamadai, K; Mehta, P R; Pazare, A R; Agarwal, M C; Nanavati, R N

    2016-01-01

    Comparison of conventional blood culture with BACTEC 9050 for rate and time to detection of microorganisms. A prospective study was carried out in a multispecialty tertiary care teaching hospital. A total of 835 paired specimens (797 blood and 38 nonblood specimens) were collected and processed according to standard microbiological procedures by both conventional method as well as by BACTEC 9050 automated culture system. Clinical details of patients were recorded. Data were analyzed for time to detection and isolation rate by the two systems and compared. Overall culture positivity for BACTEC 9050 and the conventional system was 32% and 19.88%, respectively. Eighty-five demonstrated concordant growth, 136 specimens were culture positive by BACTEC only, and 38 specimens were culture positive by conventional only. Twelve contaminants in BACTEC and nine contaminants in conventional system were detected. Using BACTEC 9050, higher isolation was observed for Acinetobacter spp., coagulase negative Staphylococcus spp., Streptococcus spp., and Candida spp. A total of 410 patients were on antimicrobial treatment and culture positivity was significantly higher with BACTEC 9050 (P < 0.0001). There was a significant difference in the mean time to detection with BACTEC 9050 recovering 86.8% of isolates within 48 h (P < 0.0001). Although BACTEC 9050 demonstrated a significantly higher recovery of microorganisms from blood, an appropriately performed conventional blood culture can facilitate the choice of therapy.

  1. Is the Presence of Actinomyces spp. in Blood Culture Always Significant?

    PubMed

    Jeffery-Smith, Anna; Nic-Fhogartaigh, Caoimhe; Millar, Michael

    2016-04-01

    The isolation ofActinomycesspp. from sterile clinical samples is traditionally regarded as significant. We reviewed the demographic characteristics, clinical risk factors, and outcomes of patients withActinomycesspp. isolated from blood cultures in our NHS Trust and found that this is not necessarily the case. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  2. Activity of Nitazoxanide and Tizoxanide against Mycobacterium tuberculosis in vitro and in whole blood culture

    PubMed Central

    Harausz, Elizabeth P.; Chervenak, Keith A.; Good, Caryn E.; Jacobs, Michael R.; Wallis, Robert S.; Sanchez-Felix, Manuel; Boom, W. Henry

    2016-01-01

    Nitazoxanide (NTZ) and its metabolite tizoxanide (TIZ) were studied as antimycobacterial agents in vitro (in mycobacterial growth indicator tube [MGIT] cultures) and in a whole blood bactericidal assay. Both NTZ and TIZ show high protein binding. In MGIT cultures (albumin concentration=78 µM), inhibition of Mycobacterium tuberculosis growth occurred at total drug concentrations of ≥16 µg/ml, whereas in whole blood cultures (albumin concentration=350 µM), ≥128 µg/ml was required. Free drug fractions at these two conditions were estimated to be 69% and 2%, respectively. Co-incubation of NTZ and TIZ in human plasma for 72 hours nearly completely eliminated their ability to inhibit mycobacterial growth in MGIT. Interactions with plasma proteins may limit the potential of NTZ and TIZ as drugs for human tuberculosis. PMID:27156623

  3. Dietary lipids and blood cholesterol: quantitative meta-analysis of metabolic ward studies.

    PubMed Central

    Clarke, R.; Frost, C.; Collins, R.; Appleby, P.; Peto, R.

    1997-01-01

    OBJECTIVE: To determine the quantitative importance of dietary fatty acids and dietary cholesterol to blood concentrations of total, low density lipoprotein, and high density lipoprotein cholesterol. DESIGN: Meta-analysis of metabolic ward studies of solid food diets in healthy volunteers. SUBJECTS: 395 dietary experiments (median duration 1 month) among 129 groups of individuals. RESULTS: Isocaloric replacement of saturated fats by complex carbohydrates for 10% of dietary calories resulted in blood total cholesterol falling by 0.52 (SE 0.03) mmol/l and low density lipoprotein cholesterol falling by 0.36 (0.05) mmol/l. Isocaloric replacement of complex carbohydrates by polyunsaturated fats for 5% of dietary calories resulted in total cholesterol falling by a further 0.13 (0.02) mmol/l and low density lipoprotein cholesterol falling by 0.11 (0.02) mmol/l. Similar replacement of carbohydrates by monounsaturated fats produced no significant effect on total or low density lipoprotein cholesterol. Avoiding 200 mg/day dietary cholesterol further decreased blood total cholesterol by 0.13 (0.02) mmol/l and low density lipoprotein cholesterol by 0.10 (0.02) mmol/l. CONCLUSIONS: In typical British diets replacing 60% of saturated fats by other fats and avoiding 60% of dietary cholesterol would reduce blood total cholesterol by about 0.8 mmol/l (that is, by 10-15%), with four fifths of this reduction being in low density lipoprotein cholesterol. PMID:9006469

  4. One mouse, one pharmacokinetic profile: quantitative whole blood serial sampling for biotherapeutics.

    PubMed

    Joyce, Alison P; Wang, Mengmeng; Lawrence-Henderson, Rosemary; Filliettaz, Cynthia; Leung, Sheldon S; Xu, Xin; O'Hara, Denise M

    2014-07-01

    The purpose of this study was to validate the approach of serial sampling from one mouse through ligand binding assay (LBA) quantification of dosed biotherapeutic in diluted whole blood to derive a pharmacokinetic (PK) profile. This investigation compared PK parameters obtained using serial and composite sampling methods following administration of human IgG monoclonal antibody. The serial sampling technique was established by collecting 10 μL of blood via tail vein at each time point following drug administration. Blood was immediately diluted into buffer followed by analyte quantitation using Gyrolab to derive plasma concentrations. Additional studies were conducted to understand matrix and sampling site effects on drug concentrations. The drug concentration profiles, irrespective of biological matrix, and PK parameters using both sampling methods were not significantly different. There were no sampling site effects on drug concentration measurements except that concentrations were slightly lower in sodium citrated plasma than other matrices. We recommend the application of mouse serial sampling, particularly with limiting drug supply or specialized animal models. Overall the efficiencies gained by serial sampling were 40-80% savings in study cost, animal usage, study length and drug conservation while inter-subject variability across PK parameters was less than 30%.

  5. MALDI-TOF mass spectrometry for early identification of bacteria grown in blood culture bottles.

    PubMed

    Zabbe, Jean-Benoît; Zanardo, Laura; Mégraud, Francis; Bessède, Emilie

    2015-08-01

    This note reports an interesting way to rapidly identify bacteria grown from blood culture bottles. Chocolate agar plates were inoculated with 1 drop of the positive blood bottle medium. After a 3-hour incubation, the growth veil was submitted to MALDI-TOF mass spectrometry: 77% of the bacteria present have been correctly identified. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Investigation of Legionella Contamination in Bath Water Samples by Culture, Amoebic Co-Culture, and Real-Time Quantitative PCR Methods.

    PubMed

    Edagawa, Akiko; Kimura, Akio; Kawabuchi-Kurata, Takako; Adachi, Shinichi; Furuhata, Katsunori; Miyamoto, Hiroshi

    2015-10-19

    We investigated Legionella contamination in bath water samples, collected from 68 bathing facilities in Japan, by culture, culture with amoebic co-culture, real-time quantitative PCR (qPCR), and real-time qPCR with amoebic co-culture. Using the conventional culture method, Legionella pneumophila was detected in 11 samples (11/68, 16.2%). Contrary to our expectation, the culture method with the amoebic co-culture technique did not increase the detection rate of Legionella (4/68, 5.9%). In contrast, a combination of the amoebic co-culture technique followed by qPCR successfully increased the detection rate (57/68, 83.8%) compared with real-time qPCR alone (46/68, 67.6%). Using real-time qPCR after culture with amoebic co-culture, more than 10-fold higher bacterial numbers were observed in 30 samples (30/68, 44.1%) compared with the same samples without co-culture. On the other hand, higher bacterial numbers were not observed after propagation by amoebae in 32 samples (32/68, 47.1%). Legionella was not detected in the remaining six samples (6/68, 8.8%), irrespective of the method. These results suggest that application of the amoebic co-culture technique prior to real-time qPCR may be useful for the sensitive detection of Legionella from bath water samples. Furthermore, a combination of amoebic co-culture and real-time qPCR might be useful to detect viable and virulent Legionella because their ability to invade and multiply within free-living amoebae is considered to correlate with their pathogenicity for humans. This is the first report evaluating the efficacy of the amoebic co-culture technique for detecting Legionella in bath water samples.

  7. Investigation of Legionella Contamination in Bath Water Samples by Culture, Amoebic Co-Culture, and Real-Time Quantitative PCR Methods

    PubMed Central

    Edagawa, Akiko; Kimura, Akio; Kawabuchi-Kurata, Takako; Adachi, Shinichi; Furuhata, Katsunori; Miyamoto, Hiroshi

    2015-01-01

    We investigated Legionella contamination in bath water samples, collected from 68 bathing facilities in Japan, by culture, culture with amoebic co-culture, real-time quantitative PCR (qPCR), and real-time qPCR with amoebic co-culture. Using the conventional culture method, Legionella pneumophila was detected in 11 samples (11/68, 16.2%). Contrary to our expectation, the culture method with the amoebic co-culture technique did not increase the detection rate of Legionella (4/68, 5.9%). In contrast, a combination of the amoebic co-culture technique followed by qPCR successfully increased the detection rate (57/68, 83.8%) compared with real-time qPCR alone (46/68, 67.6%). Using real-time qPCR after culture with amoebic co-culture, more than 10-fold higher bacterial numbers were observed in 30 samples (30/68, 44.1%) compared with the same samples without co-culture. On the other hand, higher bacterial numbers were not observed after propagation by amoebae in 32 samples (32/68, 47.1%). Legionella was not detected in the remaining six samples (6/68, 8.8%), irrespective of the method. These results suggest that application of the amoebic co-culture technique prior to real-time qPCR may be useful for the sensitive detection of Legionella from bath water samples. Furthermore, a combination of amoebic co-culture and real-time qPCR might be useful to detect viable and virulent Legionella because their ability to invade and multiply within free-living amoebae is considered to correlate with their pathogenicity for humans. This is the first report evaluating the efficacy of the amoebic co-culture technique for detecting Legionella in bath water samples. PMID:26492259

  8. Multiplexed Quantitation of Endogenous Proteins in Dried Blood Spots by Multiple Reaction Monitoring - Mass Spectrometry

    PubMed Central

    Chambers, Andrew G.; Percy, Andrew J.; Yang, Juncong; Camenzind, Alexander G.; Borchers, Christoph H.

    2013-01-01

    Dried blood spot (DBS) sampling, coupled with multiple reaction monitoring mass spectrometry (MRM-MS), is a well-established approach for quantifying a wide range of small molecule biomarkers and drugs. This sampling procedure is simpler and less-invasive than those required for traditional plasma or serum samples enabling collection by minimally trained personnel. Many analytes are stable in the DBS format without refrigeration, which reduces the cost and logistical challenges of sample collection in remote locations. These advantages make DBS sample collection desirable for advancing personalized medicine through population-wide biomarker screening. Here we expand this technology by demonstrating the first multiplexed method for the quantitation of endogenous proteins in DBS samples. A panel of 60 abundant proteins in human blood was targeted by monitoring proteotypic tryptic peptides and their stable isotope-labeled analogs by MRM. Linear calibration curves were obtained for 40 of the 65 peptide targets demonstrating multiple proteins can be quantitatively extracted from DBS collection cards. The method was also highly reproducible with a coefficient of variation of <15% for all 40 peptides. Overall, this assay quantified 37 proteins spanning a range of more than four orders of magnitude in concentration within a single 25 min LC/MRM-MS analysis. The protein abundances of the 33 proteins quantified in matching DBS and whole blood samples showed an excellent correlation, with a slope of 0.96 and an R2 value of 0.97. Furthermore, the measured concentrations for 80% of the proteins were stable for at least 10 days when stored at −20 °C, 4 °C and 37 °C. This work represents an important first step in evaluating the integration of DBS sampling with highly-multiplexed MRM for quantitation of endogenous proteins. PMID:23221968

  9. Design and optimization of reverse-transcription quantitative PCR experiments.

    PubMed

    Tichopad, Ales; Kitchen, Rob; Riedmaier, Irmgard; Becker, Christiane; Ståhlberg, Anders; Kubista, Mikael

    2009-10-01

    Quantitative PCR (qPCR) is a valuable technique for accurately and reliably profiling and quantifying gene expression. Typically, samples obtained from the organism of study have to be processed via several preparative steps before qPCR. We estimated the errors of sample withdrawal and extraction, reverse transcription (RT), and qPCR that are introduced into measurements of mRNA concentrations. We performed hierarchically arranged experiments with 3 animals, 3 samples, 3 RT reactions, and 3 qPCRs and quantified the expression of several genes in solid tissue, blood, cell culture, and single cells. A nested ANOVA design was used to model the experiments, and relative and absolute errors were calculated with this model for each processing level in the hierarchical design. We found that intersubject differences became easily confounded by sample heterogeneity for single cells and solid tissue. In cell cultures and blood, the noise from the RT and qPCR steps contributed substantially to the overall error because the sampling noise was less pronounced. We recommend the use of sample replicates preferentially to any other replicates when working with solid tissue, cell cultures, and single cells, and we recommend the use of RT replicates when working with blood. We show how an optimal sampling plan can be calculated for a limited budget. .

  10. Potential substitution of cord blood for infant blood in the neonatal sepsis evaluation.

    PubMed

    Hansen, Anne; Forbes, Peter; Buck, Rosanne

    2005-01-01

    Evaluation of sepsis accounts for one third of all nursery triage admissions. If umbilical cord blood could be accurately substituted for infant blood, it would spare infants the discomfort of an invasive procedure and save both time and resources. While awaiting 48-hour blood culture results, we decide on clinical management based on whether the white blood cell (WBC) immature to total (I:T) granulocyte ratio is >or=0.2. Our goal was to assess the correlation of complete blood count (CBC), I:T ratio and blood culture results between umbilical cord and infant blood. We conducted a prospective cohort study comparing CBC/differential and blood culture results of paired samples of umbilical cord and infant blood from term newborns. We sent 113 paired samples of cord and infant venous blood for CBC/differential and blood culture. All 113 umbilical cord and infant blood cultures were negative, yielding a false-positive blood culture rate of zero. For 92% of babies, both the cord and infant blood I:T ratio were <0.2 or both were >or=0.2. Cord and infant WBC, hematocrit and platelet counts were moderately to highly correlated. We conclude that cord blood can be safely substituted for infant blood in routine sepsis evaluations of asymptomatic, term infants based on both the low false-positive cord blood culture rate and the significant association between high I:T ratios in cord and infant blood. Copyright (c) 2005 S. Karger AG, Basel.

  11. Quantitation of circulating tumor cells in blood samples from ovarian and prostate cancer patients using tumor-specific fluorescent ligands.

    PubMed

    He, Wei; Kularatne, Sumith A; Kalli, Kimberly R; Prendergast, Franklyn G; Amato, Robert J; Klee, George G; Hartmann, Lynn C; Low, Philip S

    2008-10-15

    Quantitation of circulating tumor cells (CTCs) can provide information on the stage of a malignancy, onset of disease progression and response to therapy. In an effort to more accurately quantitate CTCs, we have synthesized fluorescent conjugates of 2 high-affinity tumor-specific ligands (folate-AlexaFluor 488 and DUPA-FITC) that bind tumor cells >20-fold more efficiently than fluorescent antibodies. Here we determine whether these tumor-specific dyes can be exploited for quantitation of CTCs in peripheral blood samples from cancer patients. A CTC-enriched fraction was isolated from the peripheral blood of ovarian and prostate cancer patients by an optimized density gradient centrifugation protocol and labeled with the aforementioned fluorescent ligands. CTCs were then quantitated by flow cytometry. CTCs were detected in 18 of 20 ovarian cancer patients (mean 222 CTCs/ml; median 15 CTCs/ml; maximum 3,118 CTCs/ml), whereas CTC numbers in 16 gender-matched normal volunteers were negligible (mean 0.4 CTCs/ml; median 0.3 CTCs/ml; maximum 1.5 CTCs/ml; p < 0.001, chi(2)). CTCs were also detected in 10 of 13 prostate cancer patients (mean 26 CTCs/ml, median 14 CTCs/ml, maximum 94 CTCs/ml) but not in 18 gender-matched healthy donors (mean 0.8 CTCs/ml, median 1, maximum 3 CTC/ml; p < 0.0026, chi(2)). Tumor-specific fluorescent antibodies were much less efficient in quantitating CTCs because of their lower CTC labeling efficiency. Use of tumor-specific fluorescent ligands to label CTCs in peripheral blood can provide a simple, accurate and sensitive method for determining the number of cancer cells circulating in the bloodstream.

  12. Misinterpretation of Gram Stain from the Stationary Growth Phase of Positive Blood Cultures for Brucella and Acinetobacter Species.

    PubMed

    Bazzi, Ali M; Al-Tawfiq, Jaffar A; Rabaan, Ali A

    2017-01-01

    Acinetobacter baumannii and Brucella species are Gram-negative organisms that are vulnerable to misinterpretation as Gram-positive or Gram-variable in blood cultures. We assess the random errors in gram stain interpretation to reduce the likelihood of such errors and therefore patient harm. Aerobic and anaerobic blood cultures from two patients in an acute care facility in Saudi Arabia were subjected to preliminary Gram-staining. In case 1, VITEK-2 Anaerobe Identification, repeat Gram staining from a blood agar plate, Remel BactiDrop™ Oxidase test, Urea Agar urease test and real-time PCR were used to confirm presence of Brucella and absence of Coryneform species. In case 2, repeat Gram- staining from the plate and the vials, VITEK-2 Gram-Negative Identification, real-time PCR and subculture on to Columbia agar, blood agar, and MacConkey agar were carried out to identify A. baumannii . In case 1, initially pleomorphic Gram-positive bacteria were identified. Coryneform species were suspected. Tiny growth was observed after 24 h on blood agar plates, and good growth by 48 h. Presence of Brucella species was ultimately confirmed. In case 2, preliminary Gram-stain results suggested giant Gram-positive oval cocci. Further testing over 18-24 h identified A. baumannii . Oxidase test from the plate and urease test from the culture vial is recommended after apparent identification of pleomorphic Gram-positive bacilli from blood culture, once tiny growth is observed, to distinguish Brucella from Corynebacterium species. If giant Gram-positive oval cocci are indicated by preliminary Gram-staining, it is recommended that the Gram stain be repeated from the plate after 4-6 h, or culture should be tested in Triple Sugar Iron (TSI) medium and the Gram stain repeated after 2-4 h incubation.

  13. High positive predictive value of Gram stain on catheter-drawn blood samples for the diagnosis of catheter-related bloodstream infection in intensive care neonates.

    PubMed

    Deleers, M; Dodémont, M; Van Overmeire, B; Hennequin, Y; Vermeylen, D; Roisin, S; Denis, O

    2016-04-01

    Catheter-related bloodstream infections (CRBSIs) remain a leading cause of healthcare-associated infections in preterm infants. Rapid and accurate methods for the diagnosis of CRBSIs are needed in order to implement timely and appropriate treatment. A retrospective study was conducted during a 7-year period (2005-2012) in the neonatal intensive care unit of the University Hospital Erasme to assess the value of Gram stain on catheter-drawn blood samples (CDBS) to predict CRBSIs. Both peripheral samples and CDBS were obtained from neonates with clinically suspected CRBSI. Gram stain, automated culture and quantitative cultures on blood agar plates were performed for each sample. The paired quantitative blood culture was used as the standard to define CRBSI. Out of 397 episodes of suspected CRBSIs, 35 were confirmed by a positive ratio of quantitative culture (>5) or a colony count of CDBS culture >100 colony-forming units (CFU)/mL. All but two of the 30 patients who had a CDBS with a positive Gram stain were confirmed as having a CRBSI. Seven patients who had a CDBS with a negative Gram stain were diagnosed as CRBSI. The sensitivity, specificity, positive predictive value and negative predictive value of Gram stain on CDBS were 80, 99.4, 93.3 and 98.1 %, respectively. Gram staining on CDBS is a viable method for rapidly (<1 h) detecting CRBSI without catheter withdrawal.

  14. An Automated Sample Preparation Instrument to Accelerate Positive Blood Cultures Microbial Identification by MALDI-TOF Mass Spectrometry (Vitek®MS).

    PubMed

    Broyer, Patrick; Perrot, Nadine; Rostaing, Hervé; Blaze, Jérome; Pinston, Frederic; Gervasi, Gaspard; Charles, Marie-Hélène; Dachaud, Fabien; Dachaud, Jacques; Moulin, Frederic; Cordier, Sylvain; Dauwalder, Olivier; Meugnier, Hélène; Vandenesch, Francois

    2018-01-01

    Sepsis is the leading cause of death among patients in intensive care units (ICUs) requiring an early diagnosis to introduce efficient therapeutic intervention. Rapid identification (ID) of a causative pathogen is key to guide directed antimicrobial selection and was recently shown to reduce hospitalization length in ICUs. Direct processing of positive blood cultures by MALDI-TOF MS technology is one of the several currently available tools used to generate rapid microbial ID. However, all recently published protocols are still manual and time consuming, requiring dedicated technician availability and specific strategies for batch processing. We present here a new prototype instrument for automated preparation of Vitek ® MS slides directly from positive blood culture broth based on an "all-in-one" extraction strip. This bench top instrument was evaluated on 111 and 22 organisms processed using artificially inoculated blood culture bottles in the BacT/ALERT ® 3D (SA/SN blood culture bottles) or the BacT/ALERT Virtuo TM system (FA/FN Plus bottles), respectively. Overall, this new preparation station provided reliable and accurate Vitek MS species-level identification of 87% (Gram-negative bacteria = 85%, Gram-positive bacteria = 88%, and yeast = 100%) when used with BacT/ALERT ® 3D and of 84% (Gram-negative bacteria = 86%, Gram-positive bacteria = 86%, and yeast = 75%) with Virtuo ® instruments, respectively. The prototype was then evaluated in a clinical microbiology laboratory on 102 clinical blood culture bottles and compared to routine laboratory ID procedures. Overall, the correlation of ID on monomicrobial bottles was 83% (Gram-negative bacteria = 89%, Gram-positive bacteria = 79%, and yeast = 78%), demonstrating roughly equivalent performance between manual and automatized extraction methods. This prototype instrument exhibited a high level of performance regardless of bottle type or BacT/ALERT system. Furthermore, blood culture workflow could potentially

  15. Prospective comparison of eubacterial PCR and measurement of procalcitonin levels with blood culture for diagnosing septicemia in intensive care unit patients.

    PubMed

    Rowther, Farjana B; Rodrigues, Camilla S; Deshmukh, Minal S; Kapadia, Farhad N; Hegde, Ashit; Mehta, Ajita P; Joshi, Vinay R

    2009-09-01

    Rapid identification of infection has a major impact on the clinical course, management, and outcome of critically ill intensive care unit (ICU) patients. We compared the results of PCR and procalcitonin with blood culture for ICU patients suspected of having septicemia. Ninety patients (60 patients meeting the criteria for sepsis and 30 patients not meeting the criteria for sepsis) were evaluated. Compared with blood culture as the gold standard, the sensitivity, specificity, and positive and negative predictive values for PCR were 100%, 43.33%, 46.87%, and 100%, respectively, and for procalcitonin were 100%, 61.66%, 56.6%, and 100%, respectively. The average times required to produce a final result were as follows: PCR, 10 h; blood culture, 33 h; procalcitonin, 45 min. Both PCR and procalcitonin may be useful as rapid tests for detecting septicemia but compared with blood cultures lacked specificity.

  16. Utility of Acridine Orange staining for detection of bacteria from positive blood cultures.

    PubMed

    Neeraja, M; Lakshmi, V; Padmasri, C; Padmaja, K

    2017-08-01

    The diagnostic performance of AO stain was evaluated for the detection of bacteria and or fungi from positive blood cultures. The sensitivity of Gram stain (GS) was 98.26% while Acridine Orange (AO) stain proved to be more sensitive (100%) with a Positive and Negative Predictive Value of 100% each. The specificity of both the stains was 100%. Overall agreement between the two stains was 98.23% (688/700). The organisms that were missed by GS and positive by AO were Candida species (Sutton, 2006) and Gram negative bacilli (GNB) (Sutton, 2006). Sensitivity of GS was 82.35% and AO was 100% among mixed cultures. Immediate reporting of the results of AO stain would have a significant impact on clinical management of patients with serious blood stream infections. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Modeling the Blood-Brain Barrier in a 3D triple co-culture microfluidic system.

    PubMed

    Adriani, G; Ma, D; Pavesi, A; Goh, E L K; Kamm, R D

    2015-01-01

    The need for a blood-brain barrier (BBB) model that accurately mimics the physiological characteristics of the in-vivo situation is well-recognized by researchers in academia and industry. However, there is currently no in-vitro model allowing studies of neuronal growth and/or function influenced by factors from the blood that cross through the BBB. Therefore, we established a 3D triple co-culture microfluidic system using human umbilical vein endothelial cells (HUVEC) together with primary rat astrocytes and neurons. Immunostaining confirmed the successful triple co-culture system consisting of an intact BBB with tight intercellular junctions in the endothelial monolayer. The BBB selective permeability was determined by a fluorescent-based assay using dextrans of different molecular weights. Finally, neuron functionality was demonstrated by calcium imaging.

  18. [Pooled Umbilical Cord Blood Plasma for Culturing UCMSC and Ex Vivo Expanding Umbilical Cord Blood CD34⁺ Cells].

    PubMed

    Wu, Jie-Ying; Lu, Yan; Chen, Jin-Song; Wu, Shao-Qing; Tang, Xue-Wei; Li, Yan

    2015-08-01

    To investigate the feasibility of umbilical cord blood plasma (UCP) as a replacement for fetal bovine serum (FBS) for culturing mesenchymal stem cells (MSC) derived from umbilical cord, and to observe the supporting effects of these cells (served as a feeder layer) on ex vivo expanding of human umbilical cord blood CD34(+) cells. Umbilical cord blood (UCB) units were suitable if the Guangzhou cord blood bank donor selection criteria strictly were fulfilled. UCP were ready to use after the collection from the plasma depletion/reduction during the processing and pooling of suitable UCB units (at least 30 units were screened for pathogens and microorganisms, and qualified). Umbilical cord mesenchymal stem cells (UCMSC) were harvested from the umbilical cord tissue of health full-term newborns after delivery by enzyme digestion and divided into 3 groups: group 1 and 2 were cultured in the presence of DMEM/F12 containing either FBS or UCP; and group 3 was cultured in serum-free medium (StemPro® MSC SFM CTS™). Morphology, proliferation and surface marker expression were examined by flow cytometry, and the differentiation toward adipogenic and osteogenic lineages was used for investigating the effect of media on UCMSC after 3-5 passages. Next, the cells cultured in the three different media were cryopreserved and thawed, then prepared as feeder layers with the name of UCMSC(FBS), UCMSC(UCP), and UCMSC(SFM), respectively. The CD34⁺ cells were separated from UCB by magnetic activated cell sorting (MACS) and divided into 4 groups cultured in StemPro(-34) SFM medium added with hematopoietic cytokine combination (StemSpan® CC100). The control group included only CD34⁺ cells as group A (blank control) and experimental groups included UCMSC(FBS) + CD34⁺ cells as group B, UCMSC(UCP) + CD34⁺ cells as group C, UCMSC(SFM) + CD34⁺ cells as group D, and cells in all groups were cultured ex vivo for 7 days. The nucleated cell (NC) number was counted by cell counter, CD34

  19. Quantitative assessment of anthrax vaccine immunogenicity using the dried blood spot matrix.

    PubMed

    Schiffer, Jarad M; Maniatis, Panagiotis; Garza, Ilana; Steward-Clark, Evelene; Korman, Lawrence T; Pittman, Phillip R; Mei, Joanne V; Quinn, Conrad P

    2013-03-01

    The collection, processing and transportation to a testing laboratory of large numbers of clinical samples during an emergency response situation present significant cost and logistical issues. Blood and serum are common clinical samples for diagnosis of disease. Serum preparation requires significant on-site equipment and facilities for immediate processing and cold storage, and significant costs for cold-chain transport to testing facilities. The dried blood spot (DBS) matrix offers an alternative to serum for rapid and efficient sample collection with fewer on-site equipment requirements and considerably lower storage and transport costs. We have developed and validated assay methods for using DBS in the quantitative anti-protective antigen IgG enzyme-linked immunosorbent assay (ELISA), one of the primary assays for assessing immunogenicity of anthrax vaccine and for confirmatory diagnosis of Bacillus anthracis infection in humans. We have also developed and validated high-throughput data analysis software to facilitate data handling for large clinical trials and emergency response. Published by Elsevier Ltd.

  20. Lack of Utility of the Lysis-Centrifugation Blood Culture Method for Detection of Fungemia in Immunocompromised Cancer Patients

    PubMed Central

    Creger, Richard J.; Weeman, Kisa E.; Jacobs, Michael R.; Morrissey, Anne; Parker, Pamela; Fox, Robert M.; Lazarus, Hillard M.

    1998-01-01

    We retrospectively compared the utility of a fungal isolation device (Isolator) versus conventional techniques for recovering fungal organisms from blood cultures obtained from neutropenic cancer patients. Positive cultures were deemed true pathogens, possible pathogens, or contaminants according to laboratory and clinical criteria. Fifty-three patients had 66 positive blood cultures for fungi, nine on multiple occasions. In 20 episodes true pathogens were recovered, 6 from broth medium alone, 4 from the Isolator system alone, and 10 from both systems. False-negative cultures were noted in 4 of 20 (20%) cases in which broth medium was used and in 6 of 20 (30%) cases in which the Isolator system was used. Possible pathogens were detected in 4 of 66 blood culture-positive cases. Forty-two positive cultures were considered contaminants, 1 collected from standard medium and 41 of 42 (98%) which grew only in Isolators. Eleven of 18 patients with true fungal infections expired as a result of infection, while 4 of 33 patients with a contaminant expired, none from a fungal cause. We do not advocate the routine use of Isolator tubes in the evaluation of the febrile, neutropenic patient due to the high rates of false positives and of contamination. PMID:9431970

  1. Induction of vascular endothelial phenotype and cellular proliferation from human cord blood stem cells cultured in simulated microgravity

    NASA Astrophysics Data System (ADS)

    Chiu, Brian; Z-M Wan, Jim; Abley, Doris; Akabutu, John

    2005-05-01

    Recent studies have demonstrated that stem cells derived from adult hematopoietic tissues are capable of trans-differentiation into non-hematopoietic cells, and that the culture in microgravity ( μg) may modulate the proliferation and differentiation. We investigated the application of μg to human umbilical cord blood stem cells (CBSC) in the induction of vascular endothelial phenotype expression and cellular proliferation. CD34+ mononuclear cells were isolated from waste human umbilical cord blood samples and cultured in simulated μg for 14 days. The cells were seeded in rotary wall vessels (RWV) with or without microcarrier beads (MCB) and vascular endothelial growth factor was added during culture. Controls consisted of culture in 1 G. The cell cultures in RWV were examined by inverted microscopy. Cell counts, endothelial cell and leukocyte markers performed by flow-cytometry and FACS scan were assayed at days 1, 4, 7 and at the termination of the experiments. Culture in RWV revealed significantly increased cellular proliferation with three-dimensional (3D) tissue-like aggregates. At day 4, CD34+ cells cultured in RWV bioreactor without MCB developed vascular tubular assemblies and exhibited endothelial phenotypic markers. These data suggest that CD34+ human umbilical cord blood progenitors are capable of trans-differentiation into vascular endothelial cell phenotype and assemble into 3D tissue structures. Culture of CBSC in simulated μg may be potentially beneficial in the fields of stem cell biology and somatic cell therapy.

  2. Assessment of clinical significance of positive blood cultures of relatively low-virulence isolates.

    PubMed

    Hirakata, Y; Furuya, N; Iwata, M; Kashitani, F; Ishikawa, M; Yumoto, S; Yasui, K; Endoh, H; Marui, A; Kaku, M; Tateda, K; Yamaguchi, K

    1996-03-01

    In Omori Hospital, Toho University School of Medicine, relatively low-virulence blood isolates, including coagulase-negative staphylococci (CNS), enterococci and nonfermentative gram-negative rods other than Pseudomonas aeruginosa comprised c. 60% of total blood isolates. A retrospective study was conducted to assess their clinical significance by reviewing a total of 91 hospital charts. The physicians' assessments of these positive blood cultures as recorded in the charts were classified into four categories--sepsis, possible sepsis, contamination and no comment. The episodes classified as sepsis accounted for 5.0-19.6%. These episodes were also evaluated by a graded clinical significance score based on multiple factors, including number of positive cultures and clinical signs. The scores for the 91 episodes covered a wide range from 1 to 9, indicating that both contaminants and causative organisms may have been involved. The episodes judged as sepsis or possible sepsis tended to have higher scores. The scores for the episodes associated with enterococci were also higher than those involving CNS or non-fermentative gram-negative rods. The scores for episodes associated with intravenous hyperalimentation catheters were higher than those not associated with the catheters.

  3. [Diagnostic value of quantitative cultures of endotracheal aspirate in ventilator-associated pneumonia: a multicenter study].

    PubMed

    Valencia Arango, M; Torres Martí, A; Insausti Ordeñana, J; Alvarez Lerma, F; Carrasco Joaquinet, N; Herranz Casado, M; Tirapu León, J P

    2003-09-01

    To study the validity of quantitative cultures of tracheal aspirate (TA) in comparison with the plugged telescoping catheter (PTC) for the diagnosis of mechanical ventilator-associated pneumonia. Prospective multicenter study enrolling patients undergoing mechanical ventilation for longer than 72 hours. TA samples were collected from patients with suspected ventilator-associated pneumonia, followed by PTC sampling. Quantitative cultures were performed on all samples. Patients were classified according to the presence or not of pneumonia, based on clinical and radiologic criteria, clinical course and autopsy findings. The cutoff points were > or = 103 colony-forming units (cfu)/mL for PTC cultures; the TA cutoffs analyzed were > or = 105 and > or = 106 cfu/mL. Of the 120 patients studied, 84 had diagnoses of pneumonia and 36 did not (controls). The sensitivity values for TA > or = 106, TA > or = 105, and PTC, respectively, were 54% (95% confidence interval [CI], 42%-64%), 71% (95% CI, 60%-81%), and 68% (95% CI, 57%-78%). The specificity values were 75% (95% CI, 58%-88%), 58% (95% CI, 41%-74%), and 75% (95% CI, 58%-88%), respectively. Staphylococcus aureus was the microorganism most frequently isolated in both TA and PTC samples, followed in frequency by Pseudomomonas aeruginosa in TA samples and Haemophilus influenzae in PTC samples. No significant differences were found between the sensitivity of TA > or = 105 and that of PTC, nor between the specificities of TA > or = 106 and PTC. No differences in the specificities of PTC and TA were found when a TA cutoff of > or = 106 cfu/ml was used. Moreover, at a cutoff of > or = 105 the sensitivity of TA was not statistically different from that of PTC. Quantitative cultures of TA can be considered acceptable for the diagnosis of ventilator-associated pneumonia.

  4. Multiplex Identification of Gram-Positive Bacteria and Resistance Determinants Directly from Positive Blood Culture Broths: Evaluation of an Automated Microarray-Based Nucleic Acid Test

    PubMed Central

    Buchan, Blake W.; Ginocchio, Christine C.; Manii, Ryhana; Cavagnolo, Robert; Pancholi, Preeti; Swyers, Lettie; Thomson, Richard B.; Anderson, Christopher; Kaul, Karen; Ledeboer, Nathan A.

    2013-01-01

    Background A multicenter study was conducted to evaluate the diagnostic accuracy (sensitivity and specificity) of the Verigene Gram-Positive Blood Culture Test (BC-GP) test to identify 12 Gram-positive bacterial gene targets and three genetic resistance determinants directly from positive blood culture broths containing Gram-positive bacteria. Methods and Findings 1,252 blood cultures containing Gram-positive bacteria were prospectively collected and tested at five clinical centers between April, 2011 and January, 2012. An additional 387 contrived blood cultures containing uncommon targets (e.g., Listeria spp., S. lugdunensis, vanB-positive Enterococci) were included to fully evaluate the performance of the BC-GP test. Sensitivity and specificity for the 12 specific genus or species targets identified by the BC-GP test ranged from 92.6%–100% and 95.4%–100%, respectively. Identification of the mecA gene in 599 cultures containing S. aureus or S. epidermidis was 98.6% sensitive and 94.3% specific compared to cefoxitin disk method. Identification of the vanA gene in 81 cultures containing Enterococcus faecium or E. faecalis was 100% sensitive and specific. Approximately 7.5% (87/1,157) of single-organism cultures contained Gram-positive bacteria not present on the BC-GP test panel. In 95 cultures containing multiple organisms the BC-GP test was in 71.6% (68/95) agreement with culture results. Retrospective analysis of 107 separate blood cultures demonstrated that identification of methicillin resistant S. aureus and vancomycin resistant Enterococcus spp. was completed an average of 41.8 to 42.4 h earlier using the BC-GP test compared to routine culture methods. The BC-GP test was unable to assign mecA to a specific organism in cultures containing more than one Staphylococcus isolate and does not identify common blood culture contaminants such as Micrococcus, Corynebacterium, and Bacillus. Conclusions The BC-GP test is a multiplex test capable of detecting most

  5. Revisiting the Diego Blood Group System in Amerindians: Evidence for Gene-Culture Comigration.

    PubMed

    Bégat, Christophe; Bailly, Pascal; Chiaroni, Jacques; Mazières, Stéphane

    2015-01-01

    Six decades ago the DI*A allele of the Diego blood group system was instrumental in proving Native American populations originated from Siberia. Since then, it has received scant attention. The present study was undertaken to reappraise distribution of the DI*A allele in 144 Native American populations based on current knowledge. Using analysis of variance tests, frequency distribution was studied according to geographical, environmental, and cultural parameters. Frequencies were highest in Amazonian populations. In contrast, DI*A was undetectable in subarctic, Fuegian, Panamanian, Chaco and Yanomama populations. Closer study revealed a correlation that this unequal distribution was correlated with language, suggesting that linguistic divergence was a driving force in the expansion of DI*A among Native Americans. The absence of DI*A in circumpolar Eskimo-Aleut and Na-Dene speakers was consistent with a late migratory event confined to North America. Distribution of DI*A in subtropical areas indicated that gene and culture exchanges were more intense within than between ecozones. Bolstering the utility of classical genetic markers in biological anthropology, the present study of the expansion of Diego blood group genetic polymorphism in Native Americans shows strong evidence of gene-culture comigration.

  6. [Infective endocarditis in intensive cardiac care unit - clinical and biochemical differences of blood-culture negative infective endocarditis].

    PubMed

    Kaziród-Wolski, Karol; Sielski, Janusz; Ciuraszkiewicz, Katarzyna

    2017-01-23

    Diagnosis and treatment of infective endocarditis (IE) is still a challenge for physicians. Group of patients with the worst prognosis is treated in Intensive Cardiac Care Unit (ICCU). Etiologic agent can not be identified in a substantial number of patients. The aim of study is to find differences between patients with blood culture negative infective endocarditis (BCNIE) and blood culture positive infective endocarditis (BCPIE) treated in ICCU by comparing their clinical course and laboratory parameters. Retrospective analysis of 30 patients with IE hospitalized in ICCU Swietokrzyskie Cardiac Centre between 2010 and 2016. This group consist of 26 men (86,67%) and 4 women (13,3%). Mean age was 58 years ±13. Most of the cases were new disease, recurrence of the disease was observed in 2 cases (6,7%). 8 patients (26,7%) required artificial ventilation, 11 (36,7%) received inotropes and 6 (20%) vasopresors. In 14 (46,7%) cases blood cultures was negative (BCNIE), the rest of patients (16, 53,3%) was blood cultures - positive infective endocarditis (BCIE). Both of the groups were clinically similar. There were no statistically significant differences in incidence of cardiac implants, localization of bacterial vegetations, administered catecholamines, antibiotic therapy, artificial ventilation, surgical treatment, complication and in-hospital mortality. Incidence of cardiac complications in all of BCNIE cases and in 81,3% cases of BCPIE draws attention, but it is not statistically significant difference (p=0,08). There was statistically significant difference in mean BNP blood concentration (3005,17 ng/ml ±2045,2 vs 1013,42 ng/ml ±1087,6; p=0,01), but there were no statistically significant differences in rest of laboratory parameters. BCNIE group has got higher mean BNP blood concentration than BCPIE group. There were no statistically significant differences between these groups in others laboratory parameters, clinical course and administered antibiotic therapy

  7. A hanging drop culture method to study terminal erythroid differentiation.

    PubMed

    Gutiérrez, Laura; Lindeboom, Fokke; Ferreira, Rita; Drissen, Roy; Grosveld, Frank; Whyatt, David; Philipsen, Sjaak

    2005-10-01

    To design a culture method allowing the quantitative and qualitative analysis of terminal erythroid differentiation. Primary erythroid progenitors derived either from mouse tissues or from human umbilical cord blood were differentiated using hanging drop cultures and compared to methylcellulose cultures. Cultured cells were analyzed by FACS to assess differentiation. We describe a practical culture method by adapting the previously described hanging drop culture system to conditions allowing terminal differentiation of primary erythroid progenitors. Using minimal volumes of media and small numbers of cells, we obtained quantitative terminal erythroid differentiation within two days of culture in the case of murine cells and 4 days in the case of human cells. The established methods for ex vivo culture of primary erythroid progenitors, such as methylcellulose-based burst-forming unit-erythroid (BFU-E) and colony-forming unit-erythroid (CFU-E) assays, allow the detection of committed erythroid progenitors but are of limited value to study terminal erythroid differentiation. We show that the application of hanging drop cultures is a practical alternative that, in combination with clonogenic assays, enables a comprehensive assessment of the behavior of primary erythroid cells ex vivo in the context of genetic and drug-induced perturbations.

  8. Blood in ancient Jewish culture.

    PubMed

    Kottek, Samuel S

    2005-01-01

    The article analyzes the Jewish attitude towards blood, conceived both as the vehicle of life, and as a polluting product of feminine bodies. The author analyzes numerous Biblical sources concerning the 'unapproachable' blood of menstruation, the role of blood in the generation of the fetus, the blood as source of illness, the practice of bloodletting, and finally the idea that male menstruation exists as a peculiarity of the Jews.

  9. Skin antiseptics in venous puncture site disinfection for preventing blood culture contamination: A Bayesian network meta-analysis of randomized controlled trials.

    PubMed

    Liu, Wenjie; Duan, Yuchen; Cui, Wenyao; Li, Li; Wang, Xia; Dai, Heling; You, Chao; Chen, Maojun

    2016-07-01

    To compare the efficacy of several antiseptics in decreasing the blood culture contamination rate. Network meta-analysis. Electronic searches of PubMed and Embase were conducted up to November 2015. Only randomized controlled trials or quasi-randomized controlled trials were eligible. We applied no language restriction. A comprehensive review of articles in the reference lists was also accomplished for possible relevant studies. Relevant studies evaluating efficacy of different antiseptics in venous puncture site for decreasing the blood culture contamination rate were included. The data were extracted from the included randomized controlled trials by two authors independently. The risk of bias was evaluated using Detsky scale by two authors independently. We used WinBUGS1.43 software and statistic model described by Chaimani to perform this network meta-analysis. Then graphs of statistical results of WinBUGS1.43 software were generated using 'networkplot', 'ifplot', 'netfunnel' and 'sucra' procedure by STATA13.0. Odds ratio and 95% confidence intervals were assessed for dichotomous data. A probability of p less than 0.05 was considered to be statistically significant. Compared with ordinary meta-analyses, this network meta-analysis offered hierarchies for the efficacy of different antiseptics in decreasing the blood culture contamination rate. Seven randomized controlled trials involving 34,408 blood samples were eligible for the meta-analysis. No significant difference was found in blood culture contamination rate among different antiseptics. No significant difference was found between non-alcoholic antiseptics and alcoholic antiseptics, alcoholic chlorhexidine and povidone iodine, chlorhexidine and iodine compounds, povidone iodine and iodine tincture in this aspect, respectively. Different antiseptics may not affect the blood culture contamination rate. Different intervals between the skin disinfection and the venous puncture, the different settings (emergency

  10. Integration of DPC and clinical microbiological data in Japan reveals importance of confirming a negative follow-up blood culture in patients with MRSA bacteremia.

    PubMed

    Miyamoto, Naoki; Yahara, Koji; Horita, Rie; Yano, Tomomi; Tashiro, Naotaka; Morii, Daiichi; Tsutsui, Atsuko; Yaita, Kenichiro; Shibayama, Keigo; Watanabe, Hiroshi

    2017-10-01

    Methicillin-resistant Staphylococcus aureus (MRSA) bacteremia is one of the commonest and most life-threatening of all infectious diseases. The morbidity and mortality rates associated with MRSA bacteremia are higher than those associated with bacteremia caused by other pathogens. A common guideline in MRSA bacteremia treatment is to confirm bacteremia clearance through additional blood cultures 2-4 days after initial positive cultures and as needed thereafter. However, no study has presented statistical evidence of how and to what extent confirming a negative follow-up blood culture impacts clinical outcome. We present this evidence for the first time, by combining clinical microbiological data of blood cultures and the DPC administrative claims database; both had been systematically accumulated through routine medical care in hospitals. We used electronic medical records to investigate the clinical background and infection source in detail. By analyzing data from a university hospital, we revealed how survival curves change when a negative follow-up blood culture is confirmed. We also demonstrated confirmation of a negative culture is significantly associated with clinical outcomes: there was a more than three-fold increase in mortality risk (after adjusting for clinical background) if a negative blood culture was not confirmed within 14 days of the initial positive blood culture. Although we used data from only one university hospital, our novel approach and results will be a basis for future studies in several hospitals in Japan to provide statistical evidence of the clinical importance of confirming a negative follow-up blood culture in bacteremia patients, including those with MRSA infections. Copyright © 2017 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  11. Time-to-positivity, type of culture media and oxidase test performed on positive blood culture vials to predict Pseudomonas aeruginosa in patients with Gram-negative bacilli bacteraemia.

    PubMed

    Cobos-Triguero, N; Zboromyrska, Y; Morata, L; Alejo, I; De La Calle, C; Vergara, A; Cardozo, C; Arcas, M P; Soriano, A; Marco, F; Mensa, J; Almela, M; Martínez, J A

    2017-02-01

    The aim of this study was to determine the usefulness of oxidase test and time-to-positivity (TTP) in aerobic and anaerobic blood culture vials to detect the presence of Pseudomonas aeruginosa in patients with Gram-negative bacilli (GNB) bacteraemia. TTP was recorded for each aerobic and anaerobic blood culture vial of monomicrobial bacteraemia due to GNB. Oxidase test was performed in a pellet of the centrifuged content of the positive blood culture. An algorithm was developed in order to perform the oxidase test efficiently taking into account TTP and type of vial. A total of 341 episodes of GNB bacteraemia were analysed. Sensitivity, specificity, positive predictive value and negative predictive value of the oxidase test performed on positive vials with GNB to predict P. aeruginosa were 95%, 99%, 91%, and 99%, respectively. When growth was first or exclusively detected in anaerobic vials, P. aeruginosa was never identified hence the performance of the oxidase test could be avoided. When growth was only or first detected in aerobic vials, a TTP≥8h predicted P. aeruginosa in 37% or cases (63 of 169), therefore oxidase test is highly recommended. Oxidase test performed onto positive blood culture vials previously selected by TTP and type of vials is an easy and inexpensive way to predict P. aeruginosa. In most cases, this can lead to optimization of treatment in less than 24 hours.

  12. Sample preparation method influences direct identification of anaerobic bacteria from positive blood culture bottles using MALDI-TOF MS.

    PubMed

    Jeverica, Samo; Nagy, Elisabeth; Mueller-Premru, Manica; Papst, Lea

    2018-05-15

    Rapid detection and identification of anaerobic bacteria from blood is important to adjust antimicrobial therapy by including antibiotics with activity against anaerobic bacteria. Limited data is available about direct identification of anaerobes from positive blood culture bottles using MALDI-TOF mass spectrometry (MS). In this study, we evaluated the performance of two sample preparation protocols for direct identification of anaerobes from positive blood culture bottles, the MALDI Sepsityper kit (Sepsityper) and the in-house saponin (saponin) method. Additionally, we compared two blood culture bottle types designed to support the growth of anaerobic bacteria, the BacT/ALERT-FN Plus (FN Plus) and the BACTEC-Lytic (Lytic), and their influence on direct identification. A selection of 30 anaerobe strains belonging to 22 different anaerobic species (11 reference strains and 19 clinical isolates) were inoculated to 2 blood culture bottle types in duplicate. In total, 120 bottles were inoculated and 99.2% (n = 119) signalled growth within 5 days of incubation. The Sepsityper method correctly identified 56.3% (n = 67) of anaerobes, while the saponin method correctly identified 84.9% (n = 101) of anaerobes with at least log(score) ≥1.6 (low confidence correct identification), (p < 0.001). Gram negative anaerobes were better identified with the saponin method (100% vs. 46.5%; p < 0.001), while Gram positive anaerobes were better identified with the Sepsityper method (70.8% vs. 62.5%; p = 0.454). Average log(score) values among only those isolates that were correctly identified simultaneously by both sample preparation methods were 2.119 and 2.029 in favour of the Sepsityper method, (p = 0.019). The inoculated bottle type didn't influence the performance of the two sample preparation methods. We confirmed that direct identification from positive blood culture bottles with MALDI-TOF MS is reliable for anaerobic bacteria. However, the results

  13. Rapid identification of bacteria from bioMérieux BacT/ALERT blood culture bottles by MALDI-TOF MS.

    PubMed

    Haigh, J D; Green, I M; Ball, D; Eydmann, M; Millar, M; Wilks, M

    2013-01-01

    Several studies have reported poor results when trying to identify microorganisms directly from the bioMérieux BacT/ALERT blood culture system using matrix-assisted laser desorption/ionisation-time of flight (MALDI-TOF) mass spectrometry. The aim of this study is to evaluate two new methods, Sepsityper and an enrichment method for direct identification of microorganisms from this system. For both methods the samples were processed using the Bruker Microflex LT mass spectrometer (Biotyper) using the Microflex Control software to obtain spectra. The results from direct analysis were compared with those obtained by subculture and subsequent identification. A total of 350 positive blood cultures were processed simultaneously by the two methods. Fifty-three cultures were polymocrobial or failed to grow any organism on subculture, and these results were not included as there was either no subculture result, or for polymicrobial cultures it was known that the Biotyper would not be able to distinguish the constituent organisms correctly. Overall, the results showed that, contrary to previous reports, it is possible to identify bacteria directly from bioMérieux blood culture bottles, as 219/297 (74%) correct identifications were obtained using the Bruker Sepsityper method and 228/297 (77%) were obtained for the enrichment method when there is only one organism was present. Although the enrichment method was simpler, the reagent costs for the Sepsityper method were approximately pound 4.00 per sample compared to pound 0.50. An even simpler and cheaper method, which was less labour-intensive and did not require further reagents, was investigated. Seventy-seven specimens from positive signalled blood cultures were analysed by inoculating prewarmed blood agar plates and analysing any growth after 1-, 2- and 4-h periods of incubation at 37 degrees C, by either direct transfer or alcohol extraction. This method gave the highest number of correct identifications, 66/77 (86

  14. Revisiting the IFN-γ release assay: Whole blood or PBMC cultures? - And other factors of influence.

    PubMed

    Hartmann, Sofie Bruun; Emnéus, Jenny; Wolff, Anders; Jungersen, Gregers

    2016-07-01

    The interferon-γ release assay (IGRA) is a widely used test for the presence of a cell-mediated immune (CMI) response in vitro. This measure is used to test for infection with intracellular pathogens or for validating vaccine efficacy, and it is a widely used test for both human as well as cattle. However, there is no consensus whether to use whole blood cultures or purified PBMCs for the assay, and both cell populations are being used and results compared. Therefore the aim of this study was to compare different culture settings using immune cells from previously vaccinated calves, and to shed light on external factors that could influence the read out in terms of IFN-γ levels. It was found that optimal culture conditions varied between individual animals; when polyclonal activated, cells from whole blood cultures were most responsive, but when activated specifically, the optimal cell concentration/population varied with whole blood, 10×10(6)cells/ml PBMC and 5×10(6)cells/ml PBMC being the highest performing conditions. A further investigation of the distribution of cell populations in PBMCs compared to whole blood was conducted, and a significant (p<0.001) decrease in the percentage of CD3(+) T lymphocytes within the PBMCs was found. More specifically, this reduction was due to a significant (p<0.01) decrease in the percentage of γδ(+) T lymphocytes. Thus measuring immune responses on purified PBMCs might not give a physiologically relevant output. Additionally, it was tested if the choice of incubation plate would interfere with the level of secreted IFN-γ in whole blood cultures from five calves. Six plates (a-f) were tested and no significant difference in absolute levels of IFN-γ was detected in the six plates when cells were polyclonal and specifically activated. However, we observed a significant (p<0.05) higher background level in a flat-bottom plate from Corning® (cat# 3595) (plate d) compared to two different flat-bottom plates from Corning

  15. Quantitative Assessment of a Field-Based Course on Integrative Geology, Ecology and Cultural History

    ERIC Educational Resources Information Center

    Sheppard, Paul R.; Donaldson, Brad A.; Huckleberry, Gary

    2010-01-01

    A field-based course at the University of Arizona called Sense of Place (SOP) covers the geology, ecology and cultural history of the Tucson area. SOP was quantitatively assessed for pedagogical effectiveness. Students of the Spring 2008 course were given pre- and post-course word association surveys in order to assess awareness and comprehension…

  16. Fluorescence In Situ Hybridization with Peptide Nucleic Acid Probes for Rapid Identification of Candida albicans Directly from Blood Culture Bottles

    PubMed Central

    Rigby, Susan; Procop, Gary W.; Haase, Gerhard; Wilson, Deborah; Hall, Geraldine; Kurtzman, Cletus; Oliveira, Kenneth; Von Oy, Sabina; Hyldig-Nielsen, Jens J.; Coull, James; Stender, Henrik

    2002-01-01

    A new fluorescence in situ hybridization (FISH) method that uses peptide nucleic acid (PNA) probes for identification of Candida albicans directly from positive-blood-culture bottles in which yeast was observed by Gram staining (herein referred to as yeast-positive blood culture bottles) is described. The test (the C. albicans PNA FISH method) is based on a fluorescein-labeled PNA probe that targets C. albicans 26S rRNA. The PNA probe is added to smears made directly from the contents of the blood culture bottle and hybridized for 90 min at 55°C. Unhybridized PNA probe is removed by washing of the mixture (30 min), and the smears are examined by fluorescence microscopy. The specificity of the method was confirmed with 23 reference strains representing phylogenetically related yeast species and 148 clinical isolates covering the clinically most significant yeast species, including C. albicans (n = 72), C. dubliniensis (n = 58), C. glabrata (n = 5), C. krusei (n = 2), C. parapsilosis (n = 4), and C. tropicalis (n = 3). The performance of the C. albicans PNA FISH method as a diagnostic test was evaluated with 33 routine and 25 simulated yeast-positive blood culture bottles and showed 100% sensitivity and 100% specificity. It is concluded that this 2.5-h method for the definitive identification of C. albicans directly from yeast-positive blood culture bottles provides important information for optimal antifungal therapy and patient management. PMID:12037084

  17. Reducing time to identification of aerobic bacteria and fastidious micro-organisms in positive blood cultures.

    PubMed

    Intra, J; Sala, M R; Falbo, R; Cappellini, F; Brambilla, P

    2016-12-01

    Rapid and early identification of micro-organisms in blood has a key role in the diagnosis of a febrile patient, in particular, in guiding the clinician to define the correct antibiotic therapy. This study presents a simple and very fast method with high performances for identifying bacteria by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) after only 4 h of incubation. We used early bacterial growth on PolyViteX chocolate agar plates inoculated with five drops of blood-broth medium deposited in the same point and spread with a sterile loop, followed by a direct transfer procedure on MALDI-TOF MS target slides without additional modification. Ninety-nine percentage of aerobic bacteria were correctly identified from 600 monomicrobial-positive blood cultures. This procedure allowed obtaining the correct identification of fastidious pathogens, such as Streptococcus pneumoniae, Neisseria meningitidis and Haemophilus influenzae that need complex nutritional and environmental requirements in order to grow. Compared to the traditional pathogen identification from blood cultures that takes over 24 h, the reliability of results, rapid performance and suitability of this protocol allowed a more rapid administration of optimal antimicrobial treatment in the patients. Bloodstream infections are serious conditions with a high mortality and morbidity rate. Rapid identification of pathogens and appropriate antimicrobial therapy have a key role for successful patient outcome. In this work, we developed a rapid, simplified, accurate, and efficient method, reaching 99 % identification of aerobic bacteria from monomicrobial-positive blood cultures by using early growth on enriched medium, direct transfer to target plate without additional procedures, matrix-assisted laser desorption ionization-time of flight mass spectrometry and SARAMIS database. The application of this protocol allows to anticipate appropriate antibiotic therapy.

  18. IDENTIFICATION OF BACTERIA IN BLOOD CULTURES FROM CLINICALLY ILL CAPTIVE ANTILLEAN MANATEES (TRICHECHUS MANATUS MANATUS).

    PubMed

    Silva, Mariana C O; Attademo, Fernanda F L; Freire, Augusto C B; Sousa, Glaucia P; Luna, Fábia O; Lima, Débora C V; Mota, Rinaldo A; Mendes, Emiko S; Silva, Jean C R

    2017-03-01

    Between September 2001 and March 2013, 62 bacterial cultures (37 aerobic and 25 anaerobic) were performed on 37 blood samples from 23 Antillean manatees ( Trichechus manatus manatus) that were kept in captivity at the Brazilian National Center for Research and Conservation of Aquatic Mammals (CMA) in Pernambuco (CMA-PE) and Alagoas (CMA-AL), Brazil. All of the animals sampled exhibited clinical signs at the time of sampling including abscesses (n = 8), debilitation and anorexia (n = 22), and profound lethargy-moribundity (n = 7). The 4 animals with profound lethargy-moribundity died shortly after sampling of unknown causes. Bacteria were isolated from 15/37 (40.5%) and aerobic blood cultures from 13/23 animals (56.5%). None of the anaerobic cultures were positive. Aeromonas caviae , Aeromonas hydrophila , Aeromonas sp., Escherichia coli , Leclercia adecarboxylata , Pantoea agglomerans , Pseudomonas aeruginosa , Pseudomonas stutzeri , Pseudomonas sp., Sphingomonas paucimobilis , coagulase-negative Staphylococcus, and Staphylococcus epidermidis were each found in only one animal; Staphylococcus spp. was found in two; and Vibrio fluvialis in four. Thirteen samples had only one bacteria isolated, one sample had two bacteria, and one sample had three bacteria isolated. Regarding sex, age group, and origin among the manatees examined, 54.5% (6/11) of the females, 58.3% (7/12) of the males, 40% (2/5) of the calves, 66.7% (8/12) of the juveniles, 50% (3/6) of the adults, 55.5% (10/18) at CMA-PE, and 60% (3/5) at CMA-AL were found to be positive for bacterial growth during at least one sampling time. All Antillean manatees were clinically ill. Regarding clinical signs, bacteria were found in 50% (11/22) of blood samples of the animals showing debilitation and anorexia, 1 of 8 (12.5%) of blood samples of the animals showing abscesses, and 3 of 7 (42.9%) of blood samples of the animals showing profound lethargy-moribundity.

  19. The combined rapid detection and species-level identification of yeasts in simulated blood culture using a colorimetric sensor array.

    PubMed

    Shrestha, Nabin K; Lim, Sung H; Wilson, Deborah A; SalasVargas, Ana Victoria; Churi, Yair S; Rhodes, Paul A; Mazzone, Peter J; Procop, Gary W

    2017-01-01

    A colorimetric sensor array (CSA) has been demonstrated to rapidly detect and identify bacteria growing in blood cultures by obtaining a species-specific "fingerprint" of the volatile organic compounds (VOCs) produced during growth. This capability has been demonstrated in prokaryotes, but has not been reported for eukaryotic cells growing in culture. The purpose of this study was to explore if a disposable CSA could differentially identify 7 species of pathogenic yeasts growing in blood culture. Culture trials of whole blood inoculated with a panel of clinically important pathogenic yeasts at four different microorganism loads were performed. Cultures were done in both standard BacT/Alert and CSA-embedded bottles, after adding 10 mL of spiked blood to each bottle. Color changes in the CSA were captured as images by an optical scanner at defined time intervals. The captured images were analyzed to identify the yeast species. Time to detection by the CSA was compared to that in the BacT/Alert system. One hundred sixty-two yeast culture trials were performed, including strains of several species of Candida (Ca. albicans, Ca. glabrata, Ca. parapsilosis, and Ca. tropicalis), Clavispora (synonym Candida) lusitaniae, Pichia kudriavzevii (synonym Candida krusei) and Cryptococcus neoformans, at loads of 8.2 × 105, 8.3 × 103, 8.5 × 101, and 1.7 CFU/mL. In addition, 8 negative trials (no yeast) were conducted. All negative trials were correctly identified as negative, and all positive trials were detected. Colorimetric responses were species-specific and did not vary by inoculum load over the 500000-fold range of loads tested, allowing for accurate species-level identification. The mean sensitivity for species-level identification by CSA was 74% at detection, and increased with time, reaching almost 95% at 4 hours after detection. At an inoculum load of 1.7 CFU/mL, mean time to detection with the CSA was 6.8 hours (17%) less than with the BacT/Alert platform. The CSA

  20. Value of blood culture time to positivity in identifying complicated nontyphoidal Salmonella bacteremia.

    PubMed

    Chen, Shang-Yu; Weng, Tzu-Hua; Tseng, Wen-Pin; Fu, Chia-Ming; Lin, Hui-Wen; Liao, Chun-Hsing; Lee, Tai-Fen; Hsueh, Po-Ren; Fang, Cheng-Chung; Chen, Shey-Ying

    2018-02-13

    Few studies analyzed the association between blood culture time to positivity (TTP) and risk of complicated nontyphoidal Salmonella (NTS) bacteremia. We conducted a retrospective study of 206 patients (aged 60.4 ± 17.4 years) with NTS bacteremia during a 30-month period. Complicated NTS bacteremia was defined as the presence of 30-day mortality, complicated infection requiring surgery or abscess drainage, or requirement of intensive care unit admission. Serogroup D (75.7%) was the predominant isolates. Malignancy (44.7%) was the most prevalent comorbidity. Patients with rapid TTP (<10 h) were more likely to have thrombocytopenia, septic shock, persistent bacteremia, complicated infection, and a higher intensive care unit admission rate. In multivariate logistic regression model, a TTP <10 h was an independent predictor for complicated NTS bacteremia (adjusted odd ratio, 5.683, 95% confidence interval, 2.396-13.482). Our study showed that blood culture TTP provides important diagnostic and prognostic information in the treatment of NTS bacteremia patients. Copyright © 2018. Published by Elsevier Inc.

  1. Quantitative Clinical Diagnostic Analysis of Acetone in Human Blood by HPLC: A Metabolomic Search for Acetone as Indicator

    PubMed Central

    Akgul Kalkan, Esin; Sahiner, Mehtap; Ulker Cakir, Dilek; Alpaslan, Duygu; Yilmaz, Selehattin

    2016-01-01

    Using high-performance liquid chromatography (HPLC) and 2,4-dinitrophenylhydrazine (2,4-DNPH) as a derivatizing reagent, an analytical method was developed for the quantitative determination of acetone in human blood. The determination was carried out at 365 nm using an ultraviolet-visible (UV-Vis) diode array detector (DAD). For acetone as its 2,4-dinitrophenylhydrazone derivative, a good separation was achieved with a ThermoAcclaim C18 column (15 cm × 4.6 mm × 3 μm) at retention time (t R) 12.10 min and flowrate of 1 mL min−1 using a (methanol/acetonitrile) water elution gradient. The methodology is simple, rapid, sensitive, and of low cost, exhibits good reproducibility, and allows the analysis of acetone in biological fluids. A calibration curve was obtained for acetone using its standard solutions in acetonitrile. Quantitative analysis of acetone in human blood was successfully carried out using this calibration graph. The applied method was validated in parameters of linearity, limit of detection and quantification, accuracy, and precision. We also present acetone as a useful tool for the HPLC-based metabolomic investigation of endogenous metabolism and quantitative clinical diagnostic analysis. PMID:27298750

  2. Microbial identification and automated antibiotic susceptibility testing directly from positive blood cultures using MALDI-TOF MS and VITEK 2.

    PubMed

    Wattal, C; Oberoi, J K

    2016-01-01

    The study addresses the utility of Matrix Assisted Laser Desorption/Ionisation Time-Of-Flight mass spectrometry (MALDI-TOF MS) using VITEK MS and the VITEK 2 antimicrobial susceptibility testing (AST) system for direct identification (ID) and timely AST from positive blood culture bottles using a lysis-filtration method (LFM). Between July and December 2014, a total of 140 non-duplicate mono-microbial blood cultures were processed. An aliquot of positive blood culture broth was incubated with lysis buffer before the bacteria were filtered and washed. Micro-organisms recovered from the filter were first identified using VITEK MS and its suspension was used for direct AST by VITEK 2 once the ID was known. Direct ID and AST results were compared with classical methods using solid growth. Out of the 140 bottles tested, VITEK MS resulted in 70.7 % correct identification to the genus and/ or species level. For the 103 bottles where identification was possible, there was agreement in 97 samples (94.17 %) with classical culture. Compared to the routine method, the direct AST resulted in category agreement in 860 (96.5 %) of 891 bacteria-antimicrobial agent combinations tested. The results of direct ID and AST were available 16.1 hours before those of the standard approach on average. The combined use of VITEK MS and VITEK 2 directly on samples from positive blood culture bottles using a LFM technique can result in rapid and reliable ID and AST results in blood stream infections to result in early institution of targeted treatment. The combination of LFM and AST using VITEK 2 was found to expedite AST more reliably.

  3. Comparative Evaluation of Four Real-Time PCR Methods for the Quantitative Detection of Epstein-Barr Virus from Whole Blood Specimens.

    PubMed

    Buelow, Daelynn; Sun, Yilun; Tang, Li; Gu, Zhengming; Pounds, Stanley; Hayden, Randall

    2016-07-01

    Monitoring of Epstein-Barr virus (EBV) load in immunocompromised patients has become integral to their care. An increasing number of reagents are available for quantitative detection of EBV; however, there are little published comparative data. Four real-time PCR systems (one using laboratory-developed reagents and three using analyte-specific reagents) were compared with one another for detection of EBV from whole blood. Whole blood specimens seeded with EBV were used to determine quantitative linearity, analytical measurement range, lower limit of detection, and CV for each assay. Retrospective testing of 198 clinical samples was performed in parallel with all methods; results were compared to determine relative quantitative and qualitative performance. All assays showed similar performance. No significant difference was found in limit of detection (3.12-3.49 log10 copies/mL; P = 0.37). A strong qualitative correlation was seen with all assays that used clinical samples (positive detection rates of 89.5%-95.8%). Quantitative correlation of clinical samples across assays was also seen in pairwise regression analysis, with R(2) ranging from 0.83 to 0.95. Normalizing clinical sample results to IU/mL did not alter the quantitative correlation between assays. Quantitative EBV detection by real-time PCR can be performed over a wide linear dynamic range, using three different commercially available reagents and laboratory-developed methods. EBV was detected with comparable sensitivity and quantitative correlation for all assays. Copyright © 2016 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  4. Blood culture-negative endocarditis: Improving the diagnostic yield using new diagnostic tools.

    PubMed

    Fournier, Pierre-Edouard; Gouriet, Frédérique; Casalta, Jean-Paul; Lepidi, Hubert; Chaudet, Hervé; Thuny, Franck; Collart, Frédéric; Habib, Gilbert; Raoult, Didier

    2017-11-01

    Blood culture-negative endocarditis (BCNE) may represent up to 70% of all endocarditis cases, depending on series. From 2001 to 2009, we implemented in our laboratory a multimodal diagnostic strategy for BCNE that included systematized testing of blood, and when available, valvular biopsy specimens using serological, broad range molecular, and histopathological assays. A causative microorganism was identified in 62.7% of patients.In this study from January 2010 to December 2015, in an effort to increase the number of identified causative microorganisms, we prospectively added to our diagnostic protocol specific real-time (RT) polymerase chain reaction (PCR) assays targeting various endocarditis agents, and applied them to all patients with BCNE admitted to the 4 public hospitals in Marseille, France.A total of 283 patients with BCNE were included in the study. Of these, 177 were classified as having definite endocarditis. Using our new multimodal diagnostic strategy, we identified an etiology in 138 patients (78.0% of cases). Of these, 3 were not infective (2.2%) and 1 was diagnosed as having Mycobacterium bovis BCG endocarditis. By adding specific PCR assays from blood and valvular biopsies, which exhibited a significantly greater sensitivity (P < 10) than other methods, causative agents, mostly enterococci, streptococci, and zoonotic microorganisms, were identified in an additional 27 patients (14 from valves only, 11 from blood only, and 2 from both). Finally, in another 107 patients, a pathogen was detected using serology in 37, valve culture in 8, broad spectrum PCR from valvular biopsies and blood in 19 and 2, respectively, immunohistochemistry from valves in 3, and a combination of several assays in 38.By adding specific RT-PCR assays to our systematic PCR testing of patients with BCNE, we increased the diagnostic efficiency by 24.3%, mostly by detecting enterococci and streptococci that had not been detected by other diagnostic methods, but also agents

  5. Quantitation of blood lymphocytes secreting antibodies to pneumococcal polysaccharides after in vivo antigenic stimulation.

    PubMed

    Heilmann, C; Pedersen, F K

    1986-02-01

    An indirect plaque-forming cell assay detecting B cells secreting IgM, IgG and IgA antibodies against pneumococcal polysaccharides (PPS) is described. The numbers of anti-PPS-secreting cells (SC) and Ig-SC in the blood of normal persons immunized with a polyvalent PPS vaccine were quantitated. Anti-PPS-SC were recorded from the fourth to the twelfth post-vaccination day, and the maximum number was found between days 6 and 9. Quantitatively IgA anti-PPS-SC outnumbered the IgM and IgG anti-PPS-SC. Concomitant with the increase in the numbers of antibody-SC an increase in polyclonally activated IgM-, IgG- and IgA-SC was recorded. The specific anti-PPS-antibody-SC constituted 20-80% of the total numbers of Ig-SC from the sixth to the ninth post-vaccination day.

  6. Prevalence of multi-drug resistant organisms in stool of paediatric patients with acute leukaemia and correlation with blood culture positivity: A single institution experience.

    PubMed

    Shankar, Krupa; Radhakrishnan, Venkatraman; Vijayakumar, Varalakskmi; Ramamoorthy, Jaikumar; Ganesan, Prasanth; Dhanushkodi, Manikandan; Ganesan, T S; Sagar, T G

    2018-01-01

    Multi-drug resistant (MDR) bacteria are associated with increased morbidity and mortality in children with acute leukaemia. The present study was conducted to assess the prevalence of MDR bacteria in stool cultures of patients with acute leukaemia at presentation to the hospital. The results were then correlated with blood cultures when patients developed septicaemia. The study involved analysis of case records of patients with newly diagnosed acute leukaemia less than 18 years of age treated at our centre from January 2015 to December 2015. Stool cultures were sent within 72 hr of hospital admission and blood cultures were sent when clinically indicated. MDR was defined as resistance to at least one antibiotic in three or more following antimicrobial groups: cephalosporins, β-lactam/β-lactamase inhibitor, carbapenems, fluoroquinolones and aminoglycosides. The analysis included 85 patients with acute leukaemia, among whom 48 of 85 (56%) patients had positive stool cultures and 42 of 85 (50%) patients were positive for MDR bacteria. Blood cultures were positive in 13 of 48 patients (27%, seven MDR and six non-MDR) with positive stool cultures and three of 37 patients (8%, one MDR and two non-MDR) with negative stool cultures (P = 0.01). The concordance between stool and blood culture for similar organism was 61%. There were seven deaths in 48 stool culture positive patients and two deaths in 37 stool culture negative patients. This study shows the high prevalence of MDR bacteria in newly diagnosed children with acute leukaemia. Colonisation with MDR bacteria in stools is associated with increased positivity of blood cultures and mortality. © 2017 Wiley Periodicals, Inc.

  7. Preparation of positive blood cultures for direct MALDI-ToF MS identification.

    PubMed

    Robinson, Andrew M; Ussher, James E

    2016-08-01

    MALDI-ToF MS can be used to identify microorganisms directly from blood cultures. This study compared two methods of sample preparation. Similar levels of genus- (91% vs 90%) and species-level identifications (79% vs 74%) were obtained with differential centrifugation and SDS methods. The SDS method is faster and requires minimal handling. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Rapid Identification of Staphylococcus aureus Directly from Blood Cultures by Fluorescence In Situ Hybridization with Peptide Nucleic Acid Probes

    PubMed Central

    Oliveira, Kenneth; Procop, Gary W.; Wilson, Deborah; Coull, James; Stender, Henrik

    2002-01-01

    A new fluorescence in situ hybridization (FISH) method with peptide nucleic acid (PNA) probes for identification of Staphylococcus aureus directly from positive blood culture bottles that contain gram-positive cocci in clusters (GPCC) is described. The test (the S. aureus PNA FISH assay) is based on a fluorescein-labeled PNA probe that targets a species-specific sequence of the 16S rRNA of S. aureus. Evaluations with 17 reference strains and 48 clinical isolates, including methicillin-resistant and methicillin-susceptible S. aureus species, coagulase-negative Staphylococcus species, and other clinically relevant and phylogenetically related bacteria and yeast species, showed that the assay had 100% sensitivity and 96% specificity. Clinical trials with 87 blood cultures positive for GPCC correctly identified 36 of 37 (97%) of the S. aureus-positive cultures identified by standard microbiological methods. The positive and negative predictive values were 100 and 98%, respectively. It is concluded that this rapid method (2.5 h) for identification of S. aureus directly from blood culture bottles that contain GPCC offers important information for optimal antibiotic therapy. PMID:11773123

  9. Multiplex Real-Time PCR Assay for Rapid Detection of Methicillin-Resistant Staphylococci Directly from Positive Blood Cultures

    PubMed Central

    Wang, Hye-young; Kim, Sunghyun; Kim, Jungho; Park, Soon-Deok

    2014-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is the most prevalent cause of bloodstream infections (BSIs) and is recognized as a major nosocomial pathogen. This study aimed to evaluate a newly designed multiplex real-time PCR assay capable of the simultaneous detection of mecA, S. aureus, and coagulase-negative staphylococci (CoNS) in blood culture specimens. The Real-MRSA and Real-MRCoNS multiplex real-time PCR assays (M&D, Republic of Korea) use the TaqMan probes 16S rRNA for Staphylococcus spp., the nuc gene for S. aureus, and the mecA gene for methicillin resistance. The detection limit of the multiplex real-time PCR assay was 103 CFU/ml per PCR for each gene target. The multiplex real-time PCR assay was evaluated using 118 clinical isolates from various specimen types and a total of 350 positive blood cultures from a continuous monitoring blood culture system. The results obtained with the multiplex real-time PCR assay for the three targets were in agreement with those of conventional identification and susceptibility testing methods except for one organism. Of 350 positive bottle cultures, the sensitivities of the multiplex real-time PCR kit were 100% (166/166 cultures), 97.2% (35/36 cultures), and 99.2% (117/118 cultures) for the 16S rRNA, nuc, and mecA genes, respectively, and the specificities for all three targets were 100%. The Real-MRSA and Real-MRCoNS multiplex real-time PCR assays are very useful for the rapid accurate diagnosis of staphylococcal BSIs. In addition, the Real-MRSA and Real-MRCoNS multiplex real-time PCR assays could have an important impact on the choice of appropriate antimicrobial therapy, based on detection of the mecA gene. PMID:24648566

  10. Quantitative visualization of synchronized insulin secretion from 3D-cultured cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suzuki, Takahiro; Kanamori, Takao; Inouye, Satoshi

    Quantitative visualization of synchronized insulin secretion was performed in an isolated rat pancreatic islet and a spheroid of rat pancreatic beta cell line using a method of video-rate bioluminescence imaging. Video-rate images of insulin secretion from 3D-cultured cells were obtained by expressing the fusion protein of insulin and Gaussia luciferase (Insulin-GLase). A subclonal rat INS-1E cell line stably expressing Insulin-GLase, named iGL, was established and a cluster of iGL cells showed oscillatory insulin secretion that was completely synchronized in response to high glucose. Furthermore, we demonstrated the effect of an antidiabetic drug, glibenclamide, on synchronized insulin secretion from 2D- andmore » 3D-cultured iGL cells. The amount of secreted Insulin-GLase from iGL cells was also determined by a luminometer. Thus, our bioluminescence imaging method could generally be used for investigating protein secretion from living 3D-cultured cells. In addition, iGL cell line would be valuable for evaluating antidiabetic drugs. - Highlights: • An imaging method for protein secretion from 3D-cultured cells was established. • The fused protein of insulin to GLase, Insulin-GLase, was used as a reporter. • Synchronous insulin secretion was visualized in rat islets and spheroidal beta cells. • A rat beta cell line stably expressing Insulin-GLase, named iGL, was established. • Effect of an antidiabetic drug on insulin secretion was visualized in iGL cells.« less

  11. [Quantitative analysis of blood loss in liposuction].

    PubMed

    Schor, N; Zatz, R M; Mendonça, A R; Takatu, P M; Patto, G S

    1989-01-01

    This study was performed in 15 female patients submitted to suction lipectomy as an isolated procedure, to establish blood loss in the procedure. A wide variation of blood-to-fat ratios was observed (17 to 59%) with a mean blood loss in lipoaspirates of 34 +/- 3%. Internal blood losses occurring in the first 72 post-operative hours were as important as or more important than external losses, and responsible for a mean 7% fall in the level of hemoglobin. Internal blood losses occurred between 72 hours and the 7th to the 10th post-operative days and were responsible for a mean 3% fall in the level of hemoglobin. Blood losses occurring in this study were demonstrated to be greater than usually assumed. Some prophylactic measures are recommended to provide for a safer treatment of these patients: an iron supplementation during the pre-operative period; careful clinical and laboratorial screening for bleeding disorders and for the intake of drugs that can interfere with coagulation; use of smaller-diameter cannulas for aspiration, auto-transfusion when aspirating in excess of 1,000 ml, and limiting the aspiration to 1,500 ml.

  12. A new rapid method for direct antimicrobial susceptibility testing of bacteria from positive blood cultures.

    PubMed

    Barnini, Simona; Brucculeri, Veronica; Morici, Paola; Ghelardi, Emilia; Florio, Walter; Lupetti, Antonella

    2016-08-12

    Rapid identification and antimicrobial susceptibility testing (AST) of the causative agent(s) of bloodstream infections can lead to prompt appropriate antimicrobial therapy. To shorten species identification, in this study bacteria were recovered from monomicrobial blood cultures by serum separator tubes and spotted onto the target plate for direct MALDI-TOF MS identification. Proper antibiotics were selected for direct AST based on species identification. In order to obtain rapid AST results, bacteria were recovered from positive blood cultures by two different protocols: by serum separator tubes (further referred to as PR1), or after a short-term subculture in liquid medium (further referred to as PR2). The results were compared with those obtained by the method currently used in our laboratory consisting in identification by MALDI-TOF and AST by Vitek 2 or Sensititre on isolated colonies. The direct MALDI-TOF method concordantly identified with the current method 97.5 % of the Gram-negative bacteria and 96.1 % of the Gram-positive cocci contained in monomicrobial blood cultures. The direct AST by PR1 and PR2 for all isolate/antimicrobial agent combinations was concordant/correct with the current method for 87.8 and 90.5 % of Gram-negative bacteria and for 93.1 and 93.8 % of Gram-positive cocci, respectively. In particular, 100 % categorical agreement was found with levofloxacin for Enterobacteriaceae by both PR1 and PR2, and 99.0 and 100 % categorical agreement was observed with linezolid for Gram-positive cocci by PR1 and PR2, respectively. There was no significant difference in accuracy between PR1 and PR2 for Gram-negative bacteria and Gram-positive cocci. This newly described method seems promising for providing accurate AST results. Most importantly, these results would be available in a few hours from blood culture positivity, which would help clinicians to promptly confirm or streamline an effective antibiotic therapy in patients with bloodstream

  13. Estimation of polydispersity in aggregating red blood cells by quantitative ultrasound backscatter analysis.

    PubMed

    de Monchy, Romain; Rouyer, Julien; Destrempes, François; Chayer, Boris; Cloutier, Guy; Franceschini, Emilie

    2018-04-01

    Quantitative ultrasound techniques based on the backscatter coefficient (BSC) have been commonly used to characterize red blood cell (RBC) aggregation. Specifically, a scattering model is fitted to measured BSC and estimated parameters can provide a meaningful description of the RBC aggregates' structure (i.e., aggregate size and compactness). In most cases, scattering models assumed monodisperse RBC aggregates. This study proposes the Effective Medium Theory combined with the polydisperse Structure Factor Model (EMTSFM) to incorporate the polydispersity of aggregate size. From the measured BSC, this model allows estimating three structural parameters: the mean radius of the aggregate size distribution, the width of the distribution, and the compactness of the aggregates. Two successive experiments were conducted: a first experiment on blood sheared in a Couette flow device coupled with an ultrasonic probe, and a second experiment, on the same blood sample, sheared in a plane-plane rheometer coupled to a light microscope. Results demonstrated that the polydisperse EMTSFM provided the best fit to the BSC data when compared to the classical monodisperse models for the higher levels of aggregation at hematocrits between 10% and 40%. Fitting the polydisperse model yielded aggregate size distributions that were consistent with direct light microscope observations at low hematocrits.

  14. Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin Mingde; Marshall, Craig T.; Qi, Yi

    Purpose: The use of preclinical rodent models of disease continues to grow because these models help elucidate pathogenic mechanisms and provide robust test beds for drug development. Among the major anatomic and physiologic indicators of disease progression and genetic or drug modification of responses are measurements of blood vessel caliber and flow. Moreover, cardiopulmonary blood flow is a critical indicator of gas exchange. Current methods of measuring cardiopulmonary blood flow suffer from some or all of the following limitations--they produce relative values, are limited to global measurements, do not provide vasculature visualization, are not able to measure acute changes, aremore » invasive, or require euthanasia. Methods: In this study, high-spatial and high-temporal resolution x-ray digital subtraction angiography (DSA) was used to obtain vasculature visualization, quantitative blood flow in absolute metrics (ml/min instead of arbitrary units or velocity), and relative blood volume dynamics from discrete regions of interest on a pixel-by-pixel basis (100x100 {mu}m{sup 2}). Results: A series of calibrations linked the DSA flow measurements to standard physiological measurement using thermodilution and Fick's method for cardiac output (CO), which in eight anesthetized Fischer-344 rats was found to be 37.0{+-}5.1 ml/min. Phantom experiments were conducted to calibrate the radiographic density to vessel thickness, allowing a link of DSA cardiac output measurements to cardiopulmonary blood flow measurements in discrete regions of interest. The scaling factor linking relative DSA cardiac output measurements to the Fick's absolute measurements was found to be 18.90xCO{sub DSA}=CO{sub Fick}. Conclusions: This calibrated DSA approach allows repeated simultaneous visualization of vasculature and measurement of blood flow dynamics on a regional level in the living rat.« less

  15. Cellular chromosome DNA interferes with fluorescence quantitative real-time PCR detection of HBV DNA in culture medium.

    PubMed

    Pan, Xiao-Ben; Wei, Lai; Han, Jin-Chao; Gao, Yan

    2008-01-01

    Fluorescence quantitative real-time PCR (FQ-PCR) is a recently developed technique increasingly used for clinical diagnosis by detection of hepatitis B virus (HBV) DNA in serum. FQ-PCR is also used in scientific research for detection of HBV DNA in cell culture. Understanding potential FQ-PCR interference factors can improve the accuracy of HBV DNA quantification in cell culture medium. HBV positive serum was diluted with culture medium to produce three test groups with HBV DNA levels of 5 x 10(7) copies/ml (high), 5 x 10(5) copies/ml (medium), and 5 x 10(3) copies/ml (low). Chromosome DNA was extracted from HepG2 cells and then added to high, medium, and low group samples at final concentrations of 0, 12.5, 25, 50, and 100 microg/ml. The samples were quantified by FQ-PCR and data were evaluated using statistical software. No marked changes were seen in the quantitative curves for high level HBV DNA samples when the samples were supplemented with 0-100 microg/ml of chromosome DNA. Interference was observed in medium level samples when 50 and 100 microg/ml of chromosome DNA was added. Interference was also observed in low level HBV DNA samples when the concentration of added chromosome DNA was greater than 25 microg/ml. The interference was eliminated when samples were digested by DNase I prior to PCR detection. In Conclusions, the presence of cellular chromosome DNA can interfere with the detection of HBV DNA by FQ-PCR. Removal of cellular chromosome DNA from culture media prior to FQ-PCR is necessary for reliable HBV DNA quantitative detection. (c) 2007 Wiley-Liss, Inc.

  16. IDAWG: Metabolic incorporation of stable isotope labels for quantitative glycomics of cultured cells

    PubMed Central

    Orlando, Ron; Lim, Jae-Min; Atwood, James A.; Angel, Peggi M.; Fang, Meng; Aoki, Kazuhiro; Alvarez-Manilla, Gerardo; Moremen, Kelley W.; York, William S.; Tiemeyer, Michael; Pierce, Michael; Dalton, Stephen; Wells, Lance

    2012-01-01

    Robust quantification is an essential component of comparative –omic strategies. In this regard, glycomics lags behind proteomics. Although various isotope-tagging and direct quantification methods have recently enhanced comparative glycan analysis, a cell culture labeling strategy, that could provide for glycomics the advantages that SILAC provides for proteomics, has not been described. Here we report the development of IDAWG, Isotopic Detection of Aminosugars With Glutamine, for the incorporation of differential mass tags into the glycans of cultured cells. In this method, culture media containing amide-15N-Gln is used to metabolically label cellular aminosugars with heavy nitrogen. Because the amide side chain of Gln is the sole source of nitrogen for the biosynthesis of GlcNAc, GalNAc, and sialic acid, we demonstrate that culturing mouse embryonic stems cells for 72 hours in the presence of amide-15N-Gln media results in nearly complete incorporation of 15N into N-linked and O-linked glycans. The isotopically heavy monosaccharide residues provide additional information for interpreting glycan fragmentation and also allow quantification in both full MS and MS/MS modes. Thus, IDAWG is a simple to implement, yet powerful quantitative tool for the glycomics toolbox. PMID:19449840

  17. Evaluation of a direct blood culture disk diffusion antimicrobial susceptibility test.

    PubMed Central

    Doern, G V; Scott, D R; Rashad, A L; Kim, K S

    1981-01-01

    A total of 556 unique blood culture isolates of nonfastidious aerobic and facultatively anaerobic bacteria were examined by direct and standardized disk susceptibility test methods (4,234 antibiotic-organism comparisons). When discrepancies which could be accounted for by the variability inherent in disk diffusion susceptibility tests were excluded, the direct method demonstrated 96.8% overall agreement with the standardized method. A total of 1.6% minor, 1.5% major, and 0.1% very major discrepancies were noted. PMID:7325634

  18. The combined rapid detection and species-level identification of yeasts in simulated blood culture using a colorimetric sensor array

    PubMed Central

    Lim, Sung H.; Wilson, Deborah A.; SalasVargas, Ana Victoria; Churi, Yair S.; Rhodes, Paul A.; Mazzone, Peter J.; Procop, Gary W.

    2017-01-01

    Background A colorimetric sensor array (CSA) has been demonstrated to rapidly detect and identify bacteria growing in blood cultures by obtaining a species-specific “fingerprint” of the volatile organic compounds (VOCs) produced during growth. This capability has been demonstrated in prokaryotes, but has not been reported for eukaryotic cells growing in culture. The purpose of this study was to explore if a disposable CSA could differentially identify 7 species of pathogenic yeasts growing in blood culture. Methods Culture trials of whole blood inoculated with a panel of clinically important pathogenic yeasts at four different microorganism loads were performed. Cultures were done in both standard BacT/Alert and CSA-embedded bottles, after adding 10 mL of spiked blood to each bottle. Color changes in the CSA were captured as images by an optical scanner at defined time intervals. The captured images were analyzed to identify the yeast species. Time to detection by the CSA was compared to that in the BacT/Alert system. Results One hundred sixty-two yeast culture trials were performed, including strains of several species of Candida (Ca. albicans, Ca. glabrata, Ca. parapsilosis, and Ca. tropicalis), Clavispora (synonym Candida) lusitaniae, Pichia kudriavzevii (synonym Candida krusei) and Cryptococcus neoformans, at loads of 8.2 × 105, 8.3 × 103, 8.5 × 101, and 1.7 CFU/mL. In addition, 8 negative trials (no yeast) were conducted. All negative trials were correctly identified as negative, and all positive trials were detected. Colorimetric responses were species-specific and did not vary by inoculum load over the 500000-fold range of loads tested, allowing for accurate species-level identification. The mean sensitivity for species-level identification by CSA was 74% at detection, and increased with time, reaching almost 95% at 4 hours after detection. At an inoculum load of 1.7 CFU/mL, mean time to detection with the CSA was 6.8 hours (17%) less than with the

  19. Adherence of coagulase-negative staphylococci to plastic tissue culture plates: a quantitative model for the adherence of staphylococci to medical devices.

    PubMed Central

    Christensen, G D; Simpson, W A; Younger, J J; Baddour, L M; Barrett, F F; Melton, D M; Beachey, E H

    1985-01-01

    The adherence of coagulase-negative staphylococci to smooth surfaces was assayed by measuring the optical densities of stained bacterial films adherent to the floors of plastic tissue culture plates. The optical densities correlated with the weight of the adherent bacterial film (r = 0.906; P less than 0.01). The measurements also agreed with visual assessments of bacterial adherence to culture tubes, microtiter plates, and tissue culture plates. Selected clinical strains were passed through a mouse model for foreign body infections and a rat model for catheter-induced endocarditis. The adherence measurements of animal passed strains remained the same as those of the laboratory-maintained parent strain. Spectrophotometric classification of coagulase-negative staphylococci into nonadherent and adherent categories according to these measurements had a sensitivity, specificity, and accuracy of 90.6, 80.8, and 88.4%, respectively. We examined a previously described collection of 127 strains of coagulase-negative staphylococci isolated from an outbreak of intravascular catheter-associated sepsis; strains associated with sepsis were more adherent than blood culture contaminants and cutaneous strains (P less than 0.001). We also examined a collection of 84 strains isolated from pediatric patients with cerebrospinal fluid (CSF) shunts; once again, pathogenic strains were more adherent than were CSF contaminants (P less than 0.01). Finally, we measured the adherence of seven endocarditis strains. As opposed to strains associated with intravascular catheters and CSF shunts, endocarditis strains were less adherent than were saprophytic strains of coagulase-negative staphylococci. The optical densities of bacterial films adherent to plastic tissue culture plates serve as a quantitative model for the study of the adherence of coagulase-negative staphylococci to medical devices, a process which may be important in the pathogenesis of foreign body infections. Images PMID:3905855

  20. Application of solid-phase microextraction to the quantitative analysis of 1,8-cineole in blood and expired air in a Eucalyptus herbivore, the brushtail possum (Trichosurus vulpecula).

    PubMed

    Boyle, Rebecca R; McLean, Stuart; Brandon, Sue; Pass, Georgia J; Davies, Noel W

    2002-11-25

    We have developed two solid-phase microextraction (SPME) methods, coupled with gas chromatography, for quantitatively analysing the major Eucalyptus leaf terpene, 1,8-cineole, in both expired air and blood from the common brushtail possum (Trichosurus vulpecula). In-line SPME sampling (5 min at 20 degrees C room temperature) of excurrent air from an expiratory chamber containing a possum dosed orally with 1,8-cineole (50 mg/kg) allowed real-time semi-quantitative measurements reflecting 1,8-cineole blood concentrations. Headspace SPME using 50 microl whole blood collected from possums dosed orally with 1,8-cineole (30 mg/kg) resulted in excellent sensitivity (quantitation limit 1 ng/ml) and reproducibility. Blood concentrations ranged between 1 and 1380 ng/ml. Calibration curves were prepared for two concentration ranges (0.05-10 and 10-400 ng/50 microl) for the analysis of blood concentrations. Both calibration curves were linear (r(2)=0.999 and 0.994, respectively) and the equations for the two concentration ranges were consistent. Copyright 2002 Elsevier Science B.V.

  1. Rapid Identification of Bacteria in Positive Blood Culture Broths by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry▿

    PubMed Central

    Stevenson, Lindsay G.; Drake, Steven K.; Murray, Patrick R.

    2010-01-01

    Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry is a rapid, accurate method for identifying bacteria and fungi recovered on agar culture media. We report herein a method for the direct identification of bacteria in positive blood culture broths by MALDI-TOF mass spectrometry. A total of 212 positive cultures were examined, representing 32 genera and 60 species or groups. The identification of bacterial isolates by MALDI-TOF mass spectrometry was compared with biochemical testing, and discrepancies were resolved by gene sequencing. No identification (spectral score of <1.7) was obtained for 42 (19.8%) of the isolates, due most commonly to insufficient numbers of bacteria in the blood culture broth. Of the bacteria with a spectral score of ≥1.7, 162 (95.3%) of 170 isolates were correctly identified. All 8 isolates of Streptococcus mitis were misidentified as being Streptococcus pneumoniae isolates. This method provides a rapid, accurate, definitive identification of bacteria within 1 h of detection in positive blood cultures with the caveat that the identification of S. pneumoniae would have to be confirmed by an alternative test. PMID:19955282

  2. Rapid identification of bacteria in positive blood culture broths by matrix-assisted laser desorption ionization-time of flight mass spectrometry.

    PubMed

    Stevenson, Lindsay G; Drake, Steven K; Murray, Patrick R

    2010-02-01

    Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry is a rapid, accurate method for identifying bacteria and fungi recovered on agar culture media. We report herein a method for the direct identification of bacteria in positive blood culture broths by MALDI-TOF mass spectrometry. A total of 212 positive cultures were examined, representing 32 genera and 60 species or groups. The identification of bacterial isolates by MALDI-TOF mass spectrometry was compared with biochemical testing, and discrepancies were resolved by gene sequencing. No identification (spectral score of < 1.7) was obtained for 42 (19.8%) of the isolates, due most commonly to insufficient numbers of bacteria in the blood culture broth. Of the bacteria with a spectral score of > or = 1.7, 162 (95.3%) of 170 isolates were correctly identified. All 8 isolates of Streptococcus mitis were misidentified as being Streptococcus pneumoniae isolates. This method provides a rapid, accurate, definitive identification of bacteria within 1 h of detection in positive blood cultures with the caveat that the identification of S. pneumoniae would have to be confirmed by an alternative test.

  3. Evaluation of the BD Max StaphSR Assay for Rapid Identification of Staphylococcus aureus and Methicillin-Resistant S. aureus in Positive Blood Culture Broths

    PubMed Central

    Hofko, Marjeta; Hamilton, Fiona; Mackenzie, Laura; Zimmermann, Stefan; Templeton, Kate

    2015-01-01

    We evaluated the performance of the BD Max StaphSR assay for the direct detection of Staphylococcus aureus from blood culture medium. In a two-center trial, 155 blood cultures from the BD Bactec FX system and 212 from the bioMérieux BacT/Alert system were tested; 170 bottles yielded S. aureus, and all were identified correctly by the BD Max StaphSR assay. The assay required approximately 2.5 h, thus allowing rapid identification of blood cultures flagged positive. PMID:26292311

  4. Use of an automated blood culture system (BD BACTEC™) for diagnosis of prosthetic joint infections: easy and fast.

    PubMed

    Minassian, Angela M; Newnham, Robert; Kalimeris, Elizabeth; Bejon, Philip; Atkins, Bridget L; Bowler, Ian C J W

    2014-05-04

    For the diagnosis of prosthetic joint infection (PJI) automated BACTEC™ blood culture bottle methods have comparable sensitivity, specificity and a shorter time to positivity than traditional cooked meat enrichment broth methods. We evaluate the culture incubation period required to maximise sensitivity and specificity of microbiological diagnosis, and the ability of BACTEC™ to detect slow growing Propionibacteria spp. Multiple periprosthetic tissue samples taken by a standardised method from 332 patients undergoing prosthetic joint revision arthroplasty were cultured for 14 days, using a BD BACTEC™ instrumented blood culture system, in a prospective study from 1st January to 31st August 2012. The "gold standard" definition for PJI was the presence of at least one histological criterion, the presence of a sinus tract or purulence around the device. Cases where > =2 samples yielded indistinguishable isolates were considered culture-positive. 1000 BACTEC™ bottle cultures which were negative after 14 days incubation were sub-cultured for Propionibacteria spp. 79 patients fulfilled the definition for PJI, and 66 of these were culture-positive. All but 1 of these 66 culture-positive cases of PJI were detected within 3 days of incubation. Only one additional (clinically-insignificant) Propionibacterium spp. was identified on terminal subculture of 1000 bottles. Prolonged microbiological culture for 2 weeks is unnecessary when using BACTEC™ culture methods. The majority of clinically significant organisms grow within 3 days, and Propionibacteria spp. are identified without the need for terminal subculture. These findings should facilitate earlier decisions on final antimicrobial prescribing.

  5. Bactec™ blood culture bottles allied to MALDI-TOF mass spectrometry: rapid etiologic diagnosis of bacterial endophthalmitis.

    PubMed

    Tanaka, Tatiana; Oliveira, Luiza Manhezi de Freitas; Ferreira, Bruno Fortaleza de Aquino; Kato, Juliana Mika; Rossi, Flavia; Correa, Karoline de Lemes Giuntini; Pimentel, Sergio Luis Gianotti; Yamamoto, Joyce Hisae; Almeida Junior, João Nóbrega

    2017-07-01

    Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry (MS) has been used for direct identification of pathogens from blood-inoculated blood culture bottles (BCBs). We showed that MALDI-TOF MS is an useful technique for rapid identification of the causative agents of endophthalmitis from vitreous humor-inoculated BCBs with a simple protocol. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Statistical parametric mapping of stimuli-evoked changes in quantitative blood flow using extended-focus optical coherence microscopy (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Marchand, Paul J.; Bouwens, Arno; Shamaei, Vincent; Nguyen, David; Extermann, Jerome; Bolmont, Tristan; Lasser, Theo

    2016-03-01

    Magnetic Resonance Imaging has revolutionised our understanding of brain function through its ability to image human cerebral structures non-invasively over the entire brain. By exploiting the different magnetic properties of oxygenated and deoxygenated blood, functional MRI can indirectly map areas undergoing neural activation. Alongside the development of fMRI, powerful statistical tools have been developed in an effort to shed light on the neural pathways involved in processing of sensory and cognitive information. In spite of the major improvements made in fMRI technology, the obtained spatial resolution of hundreds of microns prevents MRI in resolving and monitoring processes occurring at the cellular level. In this regard, Optical Coherence Microscopy is an ideal instrumentation as it can image at high spatio-temporal resolution. Moreover, by measuring the mean and the width of the Doppler spectra of light scattered by moving particles, OCM allows extracting the axial and lateral velocity components of red blood cells. The ability to assess quantitatively total blood velocity, as opposed to classical axial velocity Doppler OCM, is of paramount importance in brain imaging as a large proportion of cortical vascular is oriented perpendicularly to the optical axis. We combine here quantitative blood flow imaging with extended-focus Optical Coherence Microscopy and Statistical Parametric Mapping tools to generate maps of stimuli-evoked cortical hemodynamics at the capillary level.

  7. Evaluation of BACTEC 9240 blood culture system by using high-volume aerobic resin media.

    PubMed Central

    Schwabe, L D; Thomson, R B; Flint, K K; Koontz, F P

    1995-01-01

    The BACTEC 9240 blood culture system (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) is one of three automated, continuous-monitoring systems that is widely used in clinical laboratories. The BACTEC 9240 was compared with the BACTEC NR 660 for the detection of organisms and bacteremic episodes; time to detection of positive cultures; number of false-positive and false-negative cultures; and time needed to load, process, and perform quality control functions by using high-volume aerobic media. Blood specimens (5,282) were inoculated in equal volumes (5 to 10 ml per bottle) into BACTEC Plus Aerobic/F (9240 system) and BACTEC Plus NR26 (660 system) bottles. Clinically significant isolates were detected in 6.6% of cultures, representing 348 microorganisms and 216 bacteremic episodes. Two hundred forty-eight microorganisms were detected by both systems, 48 by the 9240 only and 52 by the 660 only (P = not significant). Of the bacteremic episodes, 158 were detected by both systems, 27 by the 9240 only and 31 by the 660 only (P = not significant). Analysis of data by month revealed equivalent recovery rates for both systems, with the exception of a 30-day period at one study site during which the 660 system detected significantly more microorganisms. Following a proprietary hardware design retrofit of the 9240 instrument, detection rates were again equivalent for the remaining three months at this study site. Positive cultures detected by both systems were detected an average of 4.3 h faster by the 9240 system (21 versus 25.3 h). The numbers of false-positive cultures for the 9240 and 660 systems were 40 (1.0%) and 9 ( < 1.0%), respectively.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:7494044

  8. Mortality following blood culture in premature infants: increased with Gram-negative bacteremia and candidemia, but not Gram-positive bacteremia.

    PubMed

    Benjamin, Daniel K; DeLong, Elizabeth; Cotten, Charles M; Garges, Harmony P; Steinbach, William J; Clark, Reese H

    2004-03-01

    To describe survival following nosocomial bloodstream infections and quantify excess mortality associated with positive blood culture. Multicenter cohort study of premature infants. First blood culture was negative for 4648/5497 (78%) of the neonates--390/4648 (8%) died prior to discharge. Mortality prior to discharge was 19% in the 161 infants with Gram-negative rod (GNR) bacteremia, 8% in the 854 neonates with coagulase negative staphylococcus (CONS), 6% in the 169 infants infected with other Gram-positive bacteria (GP-o), and 26% in the 115 neonates with candidemia. The excess 7-day mortality was 0% for Gram-positive organisms and 83% for GNR bacteremia and candidemia. Using negative blood culture as referent, GNR [hazard ratio (HR)=2.61] and candidemia (HR=2.27) were associated with increased mortality; CONS (HR=1.08) and GP-o (HR=0.97) were not. Nosocomial GNR bacteremia and candidemia were associated with increased mortality but Gram-positive bacteremia was not.

  9. Multicenter Clinical Evaluation of BacT/Alert Virtuo Blood Culture System.

    PubMed

    Jacobs, Michael R; Mazzulli, Tony; Hazen, Kevin C; Good, Caryn E; Abdelhamed, Ayman M; Lo, Pauline; Shum, Bianche; Roman, Katharine P; Robinson, Danielle C

    2017-08-01

    BacT/Alert Virtuo is an advanced, automated blood culture system incorporating improved automation and an enhanced detection algorithm to shorten time to detection. A multicenter study of the investigational Virtuo system (bioMérieux, Inc., Durham, NC) compared to BacT/Alert 3D (BTA3D) for detection of bacteremia/fungemia in four bottle types, SA and FA Plus (aerobic) and SN and FN Plus (anaerobic), was performed in a clinical setting with patient samples in a matched system design clinical trial. Blood was added to paired aerobic or anaerobic bottles, with the volume in each bottle in each pair required to be ≤10 ml and with the volumes required to be within 30% of each other. Of 5,709 bottle sets (52.5% aerobic pairs and 47.5% anaerobic pairs), 430 (7.5%) were positive for bacterial or fungal growth, with 342 (6.0%) clinically significant and 83 (1.5%) contaminated. A total of 3,539 sets (62.0%) were volume compliant, with 203 sets (5.7%) clinically significant. The positivity rates for volume-compliant bottle pairs determined by the two systems were comparable, with 68.7% of clinically significant isolates detected by both instruments, 15.7% by Virtuo only, and 15.7% by BTA3D only. Virtuo detected microbial growth nearly 2 h sooner overall than BTA3D (mean, 15.9 h versus 17.7 h). Shorter time to detection by Virtuo was related to organism group, with the time to detection being significantly shorter for enteric Gram-negative bacilli and enterococci (means, 3.6 h and 2.3 h shorter, respectively). This large clinical study demonstrated that the Virtuo blood culture system produced results comparable to those seen with the long-established BTA3D system, with significantly shorter time to detection. Copyright © 2017 Jacobs et al.

  10. Sequential production of leukaemia inhibitory factor by blood cell culture in patients with ARDS.

    PubMed

    Gruson, D; Hilbert, G; Juzan, M; Taupin, J L; Coulon, V; Moreau, J F; Gualde, N; Gbikpi-Benissan, G

    1998-04-01

    Leukaemia inhibitory factor (LIF) is a polyfunctional cytokine integrated in cytokine networks and its concentration has been shown to be elevated in bronchoalveolar lavage fluid of patients with the acute respiratory distress syndrome (ARDS). The aim of our study was to evaluate the production of LIF by culturing blood cells from patients with ARDS. 8 patients with ARDS, 8 patients with pneumonia and 5 healthy subjects. The blood samples were taken on day 1 after onset of ARDS. LIF was measured, in the cell-free supernatant, with an enzyme-linked immunosorbent assay after 24 h, 48 h and 72 h of blood cell culture. LIF was detectable in some patients in the ARDS group: at i) at 24 h and 48 h: in 2 patients ii) at 72 h in 4/5 patients (140 +/- 231 pg/ml). Only in the 4 patients in whom LIF was measured at 72 h was ARDS associated with the multiple organ dysfunction syndrome. Furthermore, among the 5 patients with ARDS who subsequently died, 4 had a detectable LIF. We have observed that LIF was produced only in ARDS, but not in all patients. The production of LIF seems to be a good indicator of the severity of ARDS. These preliminary results must be confirmed by a larger study.

  11. Loss of the ability to generate large burst-forming unit-like megakaryocytic colonies from thawed cord blood in semisolid cultures after short term suspension culture.

    PubMed

    Eskola, M; Bäckman, S; Möttönen, S; Kekomäki, R

    2015-04-01

    Total colony-forming cells from thawed cord blood units (CBUs) include megakaryocytic colony-forming units (CFU-Mks), which survive the freezing process. The aim of this study was to evaluate whether different megakaryocytic progenitors from unseparated CBUs survive the freezing process and a short-term liquid culture. Thawed samples of CBUs were cultured in liquid medium. During the cultures, serial samples were drawn to assess the growth of different megakaryocytic progenitors in a semisolid collagen medium with identical cytokines as in the liquid medium. Megakaryocytic cells were detected using immunohistochemistry and flow cytometry. In suspension culture, the megakaryocytic progenitors almost completely lost the ability to generate large (burst-forming unit-like, BFU-like) megakaryocytic colonies in semisolid cultures (large colonies, median count per chamber d0: 7.25 vs. d7: 1.5; P < 0.0001), whereas the number of small colonies (median count per chamber d0: 7.25 vs. d7: 16.0; P = 0.0505) peaked at day seven. Further 7-day culture in suspension resulted in the decline of small colonies as well (d7: 16.0 vs. d14: 5.75; P = 0.0088). Total CFU-Mk count declined from 23.3 (range 12.5-34.0) at d0 to 7.25 (range 1.0-13.5) at d14 (P < 0.0001). Immediately post-thaw, CBUs possess an ability to generate large BFU-like megakaryocytic colonies, whereas the colonies were not detectable in most CBUs in semisolid culture after a short suspension culture. Small CFU-Mks were observed throughout the cultures. It may be that the BFU-Mk colonies matured and acquired CFU-Mk behaviour. © 2014 International Society of Blood Transfusion.

  12. Seroprevalence, molecular epidemiology and quantitation of parvovirus B19 DNA levels in Iranian blood donors.

    PubMed

    Zadsar, Maryam; Aghakhani, Arezoo; Banifazl, Mohammad; Kazemimanesh, Monireh; Tabatabaei Yazdi, Seyed Morteza; Mamishi, Setareh; Bavand, Anahita; Sadat Larijani, Mona; Ramezani, Amitis

    2018-04-16

    Human parvovirus B19 (B19) infection is common among blood donors, and healthy blood donors can transmit virus via transfusion. Due to resistance of B19 to viral inactivation methods, there is a potential concern regarding transfusion safety in blood products. We aimed to determine the seroprevalence, molecular epidemiology, and quantitation of B19 DNA levels in blood donors in Tehran, Iran. A total of 500 blood donors from Blood Transfusion Research Center were studied. ELISA was used for detection of B19 IgG and IgM and nested PCR was carried out for detection of B19 DNA. PCR products were subjected to direct sequencing. B19 viral load was determined by real time PCR. B19 IgG, IgM, and DNA were detected in 27.6, 2.6, and 1.2% of donors respectively. Ten samples (2%) were positive for both antibodies while in four cases (0.8%), B19 IgG and DNA detected simultaneously. One case had B19 IgM, IgG, and viremia concurrently. The titers of B19 DNA in four of six donors were more than 10 6  IU/mL (high level viremia) and all four cases had IgG simultaneously. All B19 isolates categorized in genotype 1A. Our findings indicated that prevalence of B19 DNA in Iranian blood donors was comparable with previous studies throughout the world. High level B19 viremia found in 0.8% of our donors and all viremic donors revealed neutralizing B19 antibody. Therefore implementation of a B19 screening test for each volunteer blood donor does not appear to be necessary but B19 testing for plasma-derived products seems important in Iranian donors. © 2018 Wiley Periodicals, Inc.

  13. A self-powered, one-step chip for rapid, quantitative and multiplexed detection of proteins from pinpricks of whole blood.

    PubMed

    Wang, Jun; Ahmad, Habib; Ma, Chao; Shi, Qihui; Vermesh, Ophir; Vermesh, Udi; Heath, James

    2010-11-21

    We describe an automated, self-powered chip based on lateral flow immunoassay for rapid, quantitative, and multiplex protein detection from pinpricks of whole blood. The device incorporates on-chip purification of blood plasma by employing inertial forces to focus blood cells away from the assay surface, where plasma proteins are captured and detected on antibody "barcode" arrays. Power is supplied from the capillary action of a piece of adsorbent paper, and sequentially drives, over a 40 minute period, the four steps required to capture serum proteins and then develop a multiplex immunoassay. An 11 protein panel is assayed from whole blood, with high sensitivity and high reproducibility. This inexpensive, self-contained, and easy to operate chip provides a useful platform for point-of-care diagnoses, particularly in resource-limited settings.

  14. In vitro evaluation of BacT/Alert FA blood culture bottles and T2Candida assay for the detection of Candida in the presence of antifungals.

    PubMed

    Beyda, Nicholas D; Amadio, Jonathan; Rodriguez, Jose R; Malinowski, Karen; Garey, Kevin W; Wanger, Audrey; Ostrosky-Zeichner, Luis

    2018-06-13

    The T2Candida assay is a novel, non-culture based assay for the diagnosis of candidemia directly from whole blood. The impact of antifungals on the performance of the T2Candida assay and blood culture bottles have not been well described. In this study, the performance of the T2Candida assay was compared to that of blood culture in detecting Candida spp. in spiked blood cultures with or without the presence of antifungals. Clinical bloodstream isolates of Candida spp. were inoculated into human whole blood at low (1 - 5 cells/mL) and high (10-50 cells/mL) concentrations with or without presence of caspofungin and fluconazole. Time to detection (TTD) was assessed for prepared samples using BacTAlert FA aerobic blood culture bottles or the T2Candida assay. In the absence of antifungals, T2Candida assay sensitivity was comparable to that of blood culture at both the low and high inoculum (95% vs. 97.5% and 100% vs. 100%, respectively) and had an average TTD that was significantly faster (5.1 hrs vs 27.2 - 30 hrs, respectively). Neither caspofungin nor fluconazole was observed to impact the sensitivity or TTD of the T2Candida assay, while fluconazole reduced overall blood culture sensitivity by 7.5% - 12.5% (at low and high inoculum, respectively) and significantly prolonged the TTD of C. albicans, C. tropicalis , and C. parapsilosis by 14.8 - 67 hrs. Neither caspofungin nor fluconazole impacted the performance of the T2Candida assay in-vitro and may be useful for the diagnosis of candidemia in patients receiving antifungal therapy. Copyright © 2018 American Society for Microbiology.

  15. Detection and quantification of Plasmodium falciparum in blood samples using quantitative nucleic acid sequence-based amplification.

    PubMed

    Schoone, G J; Oskam, L; Kroon, N C; Schallig, H D; Omar, S A

    2000-11-01

    A quantitative nucleic acid sequence-based amplification (QT-NASBA) assay for the detection of Plasmodium parasites has been developed. Primers and probes were selected on the basis of the sequence of the small-subunit rRNA gene. Quantification was achieved by coamplification of the RNA in the sample with one modified in vitro RNA as a competitor in a single-tube NASBA reaction. Parasite densities ranging from 10 to 10(8) Plasmodium falciparum parasites per ml could be demonstrated and quantified in whole blood. This is approximately 1,000 times more sensitive than conventional microscopy analysis of thick blood smears. Comparison of the parasite densities obtained by microscopy and QT-NASBA with 120 blood samples from Kenyan patients with clinical malaria revealed that for 112 of 120 (93%) of the samples results were within a 1-log difference. QT-NASBA may be especially useful for the detection of low parasite levels in patients with early-stage malaria and for the monitoring of the efficacy of drug treatment.

  16. Bacteremia after supragingival scaling and dental extraction: Culture and molecular analyses.

    PubMed

    Reis, L C; Rôças, I N; Siqueira, J F; de Uzeda, M; Lacerda, V S; Domingues, Rmcp; Miranda, K R; Saraiva, R M

    2018-05-01

    To study the incidence and magnitude of bacteremia after dental extraction and supragingival scaling. Blood samples were taken before and 5 and 30 min after dental extraction and supragingival scaling from individuals at high (n = 44) or negligible risk (n = 51) for infective endocarditis. The former received prophylactic antibiotic therapy. Samples were subjected to aerobic and anaerobic culture and quantitative real-time polymerase chain reaction to determine the incidence of bacteremia and total bacterial levels. Patients who did not receive prophylactic antibiotic therapy had a higher incidence of positive blood cultures (30% 5 min after extraction) than patients who received prophylactic antibiotic therapy (0% 5 min after extraction; p < .01). Molecular analysis did not reveal significant differences in the incidence or magnitude of bacteremia between the two patient groups either 5 or 30 min after each of the procedures evaluated. Extraction was associated with higher incidence of bacteremia than supragingival scaling by blood culture (p = .03) and molecular analysis (p = .05). Molecular methods revealed that dental extraction and supragingival scaling were associated with similar incidence of bacteremia in groups receiving or not prophylactic antibiotic therapy. However, blood culture revealed that antibiotic therapy reduced viable cultivable bacteria in the bloodstream in the extraction group. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Quantitative monitoring of lipid accumulation over time in cultured adipocytes as function of culture conditions: toward controlled adipose tissue engineering.

    PubMed

    Or-Tzadikario, Shira; Sopher, Ran; Gefen, Amit

    2010-10-01

    Adipose tissue engineering is investigated for native fat substitutes and wound healing model systems. Research and clinical applications of bioartificial fat require a quantitative and objective method to continuously measure adipogenesis in living cultures as opposed to currently used culture-destructive techniques that stain lipid droplet (LD) accumulation. To allow standardization, automatic quantification of LD size is further needed, but currently LD size is measured mostly manually. We developed an image processing-based method that does not require staining to monitor adipose cell maturation in vitro nondestructively using optical micrographs taken consecutively during culturing. We employed our method to monitor LD accumulation in 3T3-L1 and mesenchymal stem cells over 37 days. For each cell type, percentage of lipid area, number of droplets per cell, and droplet diameter were obtained every 2-3 days. In 3T3-L1 cultures, high insulin concentration (10 microg/mL) yielded a significantly different (p < 0.01) time course of all three outcome measures. In mesenchymal stem cell cultures, high fetal bovine serum concentration (12.5%) produced significantly more lipid area (p < 0.01). Our method was able to successfully characterize time courses and extents of adipogenesis and is useful for a wide range of applications testing the effects of biochemical, mechanical, and thermal stimulations in tissue engineering of bioartificial fat constructs.

  18. [Assessment of two DNA extraction methods to amplify the pneumolysin gene (PLY) from blood culture samples of Streptococcus pneumoniae].

    PubMed

    Hernández, Carolina; Durán, Claudia; Ulloa, María Teresa; Prado, Valeria

    2004-05-01

    Streptococcus pneumoniae is a common etiologic agent of invasive respiratory infections among children under 5 years of age and older adults. Isolation rates of S. pneumoniae by traditional culture techniques are low. To study the sensitivity and specificity of two different DNA extraction methods to amplify the ply gene, applied to three different types of blood culture broths, experimentally inoculated with S. pneumoniae. DNA was extracted from the cultures using an organic method or a technique that consists in dilution, washing with NaOH and concentration of the sample. This was followed by PCR amplification of a 355 pb fragment of the pneumolysin gene (ply). The organic DNA extraction method inhibited the PCR reaction at all concentrations studied (0.6 to 10(6) colony forming units/mL). Using the NaOH extraction, ply gene amplification was positive in all three blood culture broths, but only at concentrations of 10(3) colony forming units/mL, or higher. Using the same DNA extraction method, PCR was negative when the broths were inoculated with seven other related bacterial species, which results in a 100% specificity. Detection of S. pneumoniae by amplification of ply gene from blood cultures using the protocol of NaOH for DNA extraction is specific and provides results in a short lapse. However, the diagnostic sensitivity is not optimal, which limits its clinical use.

  19. Comparison of conventional PCR, quantitative PCR, bacteriological culture and the Warthin Starry technique to detect Leptospira spp. in kidney and liver samples from naturally infected sheep from Brazil.

    PubMed

    Fornazari, Felipe; da Silva, Rodrigo Costa; Richini-Pereira, Virginia Bodelão; Beserra, Hugo Enrique Orsini; Luvizotto, Maria Cecília Rui; Langoni, Helio

    2012-09-01

    Leptospirosis is an infectious disease of worldwide importance. The development of diagnostic techniques allows sick animals to be identified, reservoirs to be eliminated and the disease prevented and controlled. The present study aimed to compare different techniques for diagnosing leptospirosis in sheep. Samples of kidney, liver and blood were collected from 465 animals that originated from a slaughterhouse. The sera were analyzed by the Microscopic Agglutination Test (MAT), and kidney and liver samples of seropositive animals were analyzed using four techniques: bacteriological culture, the Warthin Starry (WS) technique, conventional PCR (cPCR), and quantitative PCR (qPCR). With the MAT, 21 animals were positive (4.5%) to serovars Hardjo (n=12), Hebdomadis (n=5), Sentot (n=2), Wolfii (n=1) and Shermani (n=1). Titers were 100 (n=10), 200 (n=2), 400 (n=6) and 1600 (n=3). No animal was positive by bacteriological culture; four animals were positive by the WS technique in kidney samples; six animals were positive by cPCR in kidney samples; and 11 animals were positive by qPCR, eight of which in kidney samples and three in liver. The bacterial quantification revealed a median of 4.3 bacteria/μL in liver samples and 36.6 bacteria/μL in kidney samples. qPCR presented the highest sensitivity among the techniques, followed by cPCR, the WS technique and bacteriological culture. These results indicate that sheep can carry leptospires of the Sejroe serogroup, and demonstrate the efficiency of quantitative PCR to detect Leptospira spp. in tissue samples. Published by Elsevier B.V.

  20. Quantitative flow and velocity measurements of pulsatile blood flow with 4D-DSA

    NASA Astrophysics Data System (ADS)

    Shaughnessy, Gabe; Hoffman, Carson; Schafer, Sebastian; Mistretta, Charles A.; Strother, Charles M.

    2017-03-01

    Time resolved 3D angiographic data from 4D DSA provides a unique environment to explore physical properties of blood flow. Utilizing the pulsatility of the contrast waveform, the Fourier components can be used to track the waveform motion through vessels. Areas of strong pulsatility are determined through the FFT power spectrum. Using this method, we find an accuracy from 4D-DSA flow measurements within 7.6% and 6.8% RMSE of ICA PCVIPR and phantom flow probe validation measurements, respectively. The availability of velocity and flow information with fast acquisition could provide a more quantitative approach to treatment planning and evaluation in interventional radiology.

  1. Biomarkers are used to predict quantitative metabolite concentration profiles in human red blood cells

    DOE PAGES

    Yurkovich, James T.; Yang, Laurence; Palsson, Bernhard O.; ...

    2017-03-06

    Deep-coverage metabolomic profiling has revealed a well-defined development of metabolic decay in human red blood cells (RBCs) under cold storage conditions. A set of extracellular biomarkers has been recently identified that reliably defines the qualitative state of the metabolic network throughout this metabolic decay process. Here, we extend the utility of these biomarkers by using them to quantitatively predict the concentrations of other metabolites in the red blood cell. We are able to accurately predict the concentration profile of 84 of the 91 (92%) measured metabolites ( p < 0.05) in RBC metabolism using only measurements of these five biomarkers.more » The median of prediction errors (symmetric mean absolute percent error) across all metabolites was 13%. Furthermore, the ability to predict numerous metabolite concentrations from a simple set of biomarkers offers the potential for the development of a powerful workflow that could be used to evaluate the metabolic state of a biological system using a minimal set of measurements.« less

  2. Biomarkers are used to predict quantitative metabolite concentration profiles in human red blood cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yurkovich, James T.; Yang, Laurence; Palsson, Bernhard O.

    Deep-coverage metabolomic profiling has revealed a well-defined development of metabolic decay in human red blood cells (RBCs) under cold storage conditions. A set of extracellular biomarkers has been recently identified that reliably defines the qualitative state of the metabolic network throughout this metabolic decay process. Here, we extend the utility of these biomarkers by using them to quantitatively predict the concentrations of other metabolites in the red blood cell. We are able to accurately predict the concentration profile of 84 of the 91 (92%) measured metabolites ( p < 0.05) in RBC metabolism using only measurements of these five biomarkers.more » The median of prediction errors (symmetric mean absolute percent error) across all metabolites was 13%. Furthermore, the ability to predict numerous metabolite concentrations from a simple set of biomarkers offers the potential for the development of a powerful workflow that could be used to evaluate the metabolic state of a biological system using a minimal set of measurements.« less

  3. Blood culture gram stain, acridine orange stain and direct sensitivity-based antimicrobial therapy of bloodstream infection in patients with trauma.

    PubMed

    Behera, B; Mathur, P; Gupta, B

    2010-01-01

    The purpose of this study was to ascertain if the simple practice of Gram stain, acridine orange stain and direct sensitivity determination of positive blood culture bottles could be used to guide early and appropriate treatment in trauma patients with clinical suspicion of sepsis. The study also aimed to evaluate the error in interpreting antimicrobial sensitivity by direct method when compared to standard method and find out if specific antibiotic-organism combination had more discrepancies. Findings from consecutive episodes of blood stream infection at an Apex Trauma centre over a 12-month period are summarized. A total of 509 consecutive positive blood cultures were subjected to Gram staining. AO staining was done in BacT/ALERT-positive Gram-stain negative blood cultures. Direct sensitivity was performed from 369 blood culture broths, showing single type of growth in Gram and acridine orange staining. Results of direct sensitivity were compared to conventional sensitivity for errors. No 'very major' discrepancy was found in this study. About 5.2 and 1.8% minor error rates were noted in gram-positive and gram-negative bacteria, respectively, while comparing the two methods. Most of the discrepancies in gram-negative bacteria were noted in beta lactam - beta lactamase inhibitor combinations. Direct sensitivity testing was not reliable for reporting of methicillin and vancomycin resistance in Staphylococci. Gram stain result together with direct sensitivity testing is required for optimizing initial antimicrobial therapy in trauma patients with clinical suspicion of sepsis. Gram staining and AO staining proved particularly helpful in the early detection of candidaemia.

  4. Evaluation of three sample preparation methods for the direct identification of bacteria in positive blood cultures by MALDI-TOF.

    PubMed

    Tanner, Hannah; Evans, Jason T; Gossain, Savita; Hussain, Abid

    2017-01-18

    Patient mortality is significantly reduced by rapid identification of bacteria from sterile sites. MALDI-TOF can identify bacteria directly from positive blood cultures and multiple sample preparation methods are available. We evaluated three sample preparation methods and two MALDI-TOF score cut-off values. Positive blood culture bottles with organisms present in Gram stains were prospectively analysed by MALDI-TOF. Three lysis reagents (Saponin, SDS, and SepsiTyper lysis bufer) were applied to each positive culture followed by centrifugation, washing and protein extraction steps. Methods were compared using the McNemar test and 16S rDNA sequencing was used to assess discordant results. In 144 monomicrobial cultures, using ≥2.000 as the cut-off value, species level identifications were obtained from 69/144 (48%) samples using Saponin, 86/144 (60%) using SDS, and 91/144 (63%) using SepsiTyper. The difference between SDS and SepsiTyper was not statistically significant (P = 0.228). Differences between Saponin and the other two reagents were significant (P < 0.01). Using ≥1.700 plus top three results matching as the cut-off value, species level identifications were obtained from 100/144 (69%) samples using Saponin, 103/144 (72%) using SDS, and 106/144 (74%) using SepsiTyper and there was no statistical difference between the methods. No true discordances between culture and direct MALDI-TOF identification were observed in monomicrobial cultures. In 32 polymicrobial cultures, MALDI-TOF identified one organism in 34-75% of samples depending on the method. This study demonstrates two inexpensive in-house detergent lysis methods are non-inferior to a commercial kit for analysis of positive blood cultures by direct MALDI-TOF in a clinical diagnostic microbiology laboratory.

  5. Direct identification of microorganisms from positive blood cultures by MALDI-TOF MS using an in-house saponin method.

    PubMed

    Yonetani, Shota; Ohnishi, Hiroaki; Ohkusu, Kiyofumi; Matsumoto, Tetsuya; Watanabe, Takashi

    2016-11-01

    Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is a fast and reliable method for the identification of bacteria. A MALDI Sepsityper kit is generally used to prepare samples obtained directly from culture bottles. However, the relatively high cost of this kit is a major obstacle to introducing this method into routine clinical use. In this study, the accuracies of three different preparation methods for rapid direct identification of bacteria from positive blood culture bottles by MALDI-TOF MS analysis were compared. In total, 195 positive bottles were included in this study. Overall, 78.5%, 68.7%, and 76.4% of bacteria were correctly identified to the genus level (score ≥1.7) directly from positive blood cultures using the Sepsityper, centrifugation, and saponin methods, respectively. The identification rates using the Sepsityper and saponin methods were significantly higher than that using the centrifugation method (Sepsityper vs. centrifugation, p<0.001; saponin vs. centrifugation, p=0.003). These results suggest that the saponin method is superior to the centrifugation method and comparable to the Sepsityper method in the accuracy of rapid bacterial identification directly from blood culture bottles, and could be a less expensive alternative to the Sepsityper method. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  6. Development of a Multiplexed Microsphere PCR for Culture-Free Detection and Gram-Typing of Bacteria in Human Blood Samples.

    PubMed

    Liang, Fang; Browne, Daniel J; Gray, Megan J; Gartlan, Kate H; Smith, David D; Barnard, Ross T; Hill, Geoffrey R; Corrie, Simon R; Markey, Kate A

    2018-05-11

    Bloodstream infection is a significant clinical problem, particularly in vulnerable patient groups such as those undergoing chemotherapy and bone marrow transplantation. Clinical diagnostics for suspected bloodstream infection remain centered around blood culture (highly variable timing, in the order of hours to days to become positive), and empiric use of broad-spectrum antibiotics is therefore employed for patients presenting with febrile neutropenia. Gram-typing provides the first opportunity to target therapy (e.g., combinations containing vancomycin or teicoplanin for Gram-positives; piperacillin-tazobactam or a carbapenem for Gram-negatives); however, current approaches require blood culture. In this study, we describe a multiplexed microsphere-PCR assay with flow cytometry readout, which can distinguish Gram-positive from Gram-negative bacterial DNA in a 3.5 h time period. The combination of a simple assay design (amplicon-dependent release of Gram-type specific Cy3-labeled oligonucleotides) and the Luminex-based readout (for quantifying each specific Cy3-labeled sequence) opens opportunities for further multiplexing. We demonstrate the feasibility of detecting common Gram-positive and Gram-negative organisms after spiking whole bacteria into healthy human blood prior to DNA extraction. Further development of DNA extraction methods is required to reach detection limits comparable to blood culture.

  7. Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Use with Positive Blood Cultures: Methodology, Performance, and Optimization.

    PubMed

    Faron, Matthew L; Buchan, Blake W; Ledeboer, Nathan A

    2017-12-01

    Early initiation of effective antibiotics for septic patients is essential for patient survival. Matrix-assisted desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has revolutionized clinical microbiology for isolate identification and has the possibility to impact how blood culture testing is performed. This review discusses the various uses of MALDI-TOF MS for the identification and susceptibility testing of positive blood cultures, the performance of these methods, and the outcomes involved with its implementation. Copyright © 2017 American Society for Microbiology.

  8. In vitro studies of the blood-brain barrier using isolated brain capillaries and cultured endothelial cells.

    PubMed

    Goldstein, G W; Betz, A L; Bowman, P D; Dorovini-Zis, K

    1986-01-01

    The endothelial cells in brain capillaries are the anatomic site of the blood-brain barrier. To learn more about the biology of these specialized cells, we developed methods to prepare suspensions of purified brain microvessels as well as primary cultures of endothelial cells in monolayer. These two preparations allow for direct investigation of the metabolism, transport properties, and receptor content of the brain capillary. We used isolated brain microvessels to study distribution of membrane carriers between the luminal and the abluminal plasma membrane of endothelial cells. We found that Na+K+-ATPase and the A-system amino-acid transport system are located predominantly on the abluminal surface of brain capillary endothelial cells. This distribution of transport carriers is consistent with the low permeability of potassium and small neutral amino acids in the blood-to-brain direction. It suggests, however, that both solutes can be actively transported across brain capillaries from the brain interstitial fluid to the blood. In tissue culture, the endothelial cells form continuous tight junctions with their neighbors. This results in a cellular layer impermeable to protein tracers. When exposed to hyperosmolar solutions, in an attempt to mimic the conditions that open the blood-brain barrier in vivo, we found a reversible separation of the tight junctions between contiguous endothelial cells. No indication of activation of pinocytosis was observed. In vitro systems provide a novel approach for studying the function of the blood-brain barrier and allow for observations not possible with intact animals.

  9. Work System Assessment to Facilitate the Dissemination of a Quality Improvement Program for Optimizing Blood Culture Use: A Case Study Using a Human Factors Engineering Approach.

    PubMed

    Xie, Anping; Woods-Hill, Charlotte Z; King, Anne F; Enos-Graves, Heather; Ascenzi, Judy; Gurses, Ayse P; Klaus, Sybil A; Fackler, James C; Milstone, Aaron M

    2017-11-20

    Work system assessments can facilitate successful implementation of quality improvement programs. Using a human factors engineering approach, we conducted a work system assessment to facilitate the dissemination of a quality improvement program for optimizing blood culture use in pediatric intensive care units at 2 hospitals. Semistructured face-to-face interviews were conducted with clinicians from Johns Hopkins All Children's Hospital and University of Virginia Medical Center. Interview data were analyzed using qualitative content analysis. Blood culture-ordering practices are influenced by various work system factors, including people, tasks, tools and technologies, the physical environment, organizational conditions, and the external environment. A clinical decision-support tool could facilitate implementation by (1) standardizing blood culture-ordering practices, (2) ensuring that prescribing clinicians review the patient's condition before ordering a blood culture, (3) facilitating critical thinking, and (4) empowering nurses to communicate with physicians and advocate for adherence to blood culture-ordering guidelines. The success of interventions for optimizing blood culture use relies heavily on the local context. A work system analysis using a human factors engineering approach can identify key areas to be addressed for the successful dissemination of quality improvement interventions. © The Author 2017. Published by Oxford University Press on behalf of The Journal of the Pediatric Infectious Diseases Society. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. Comparison of 'time to detection' values between BacT/ALERT VIRTUO and BacT/ALERT 3D instruments for clinical blood culture samples.

    PubMed

    Congestrì, Francesco; Pedna, Maria Federica; Fantini, Michela; Samuelli, Michela; Schiavone, Pasqua; Torri, Arianna; Bertini, Stefania; Sambri, Vittorio

    2017-09-01

    The early detection of bacteraemia and fungemia is of paramount importance to guide antimicrobial therapy in septic patients. In this study the 'time to detection' (TTD) value for the new blood culture system BacT/ALERT VIRTUO (VIRTUO) was evaluated in 1462 positive clinical bottles and compared with the TTD for 1601 positive clinical bottles incubated in the BacT/ALERT 3D system (BTA-3D). The most representative microorganisms isolated from bottles incubated in both blood culture systems were divided into eight categories (in order of frequency): coagulase-negative staphylococci (CoNS), Escherichia coli, Enterobacteriaceae (other than E. coli), Staphylococcus aureus, Enterococcus spp, viridans group streptococci, Pseudomonas aeruginosa, and Candida spp. The comparison of TTD values for the two blood culture systems strongly indicated that growth of the first five groups listed above was detected earlier with VIRTUO than with BTA-3D (p < 0.05). The new VIRTUO blood culture system can reduce the TTD for more than 75% of isolated microorganisms. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. Staphylococcus aureus, Staphylococcus epidermidis and Staphylococcus haemolyticus: methicillin-resistant isolates are detected directly in blood cultures by multiplex PCR.

    PubMed

    Pereira, Eliezer M; Schuenck, Ricardo P; Malvar, Karoline L; Iorio, Natalia L P; Matos, Pricilla D M; Olendzki, André N; Oelemann, Walter M R; dos Santos, Kátia R N

    2010-03-31

    In this study, we standardized and evaluated a multiplex-PCR methodology using specific primers to identify Staphylococcus aureus, Staphylococcus epidermidis and Staphylococcus haemolyticus and their methicillin-resistance directly from blood cultures. Staphylococci clinical isolates (149) and control strains (16) previously identified by conventional methods were used to establish the multiplex PCR protocol. Subsequently, this methodology was evaluated using a fast and cheap DNA extraction protocol from 25 staphylococci positive blood cultures. A wash step of the pellet with 0.1% bovine serum albumin (BSA) solution was performed to reduce PCR inhibitors. Amplicons of 154bp (mecA gene), 271bp (S. haemolyticus mvaA gene) and 108 and 124bp (S. aureus and S. epidermidis species-specific fragments, respectively) were observed. Reliable results were obtained for 100% of the evaluated strains, suggesting that this new multiplex-PCR combined with an appropriate DNA-extraction method could be useful in the laboratory for fast and accurate identification of three staphylococci species and simultaneously their methicillin resistance directly in blood cultures.

  12. Quantitative investigation of red blood cell three-dimensional geometric and chemical changes in the storage lesion using digital holographic microscopy.

    PubMed

    Jaferzadeh, Keyvan; Moon, Inkyu

    2015-11-01

    Quantitative phase information obtained by digital holographic microscopy (DHM) can provide new insight into the functions and morphology of single red blood cells (RBCs). Since the functionality of a RBC is related to its three-dimensional (3-D) shape, quantitative 3-D geometric changes induced by storage time can help hematologists realize its optimal functionality period. We quantitatively investigate RBC 3-D geometric changes in the storage lesion using DHM. Our experimental results show that the substantial geometric transformation of the biconcave-shaped RBCs to the spherocyte occurs due to RBC storage lesion. This transformation leads to progressive loss of cell surface area, surface-to-volume ratio, and functionality of RBCs. Furthermore, our quantitative analysis shows that there are significant correlations between chemical and morphological properties of RBCs.

  13. 3D cultured immortalized human hepatocytes useful to develop drugs for blood-borne HCV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aly, Hussein Hassan; Shimotohno, Kunitada; Hijikata, Makoto

    2009-02-06

    Due to the high polymorphism of natural hepatitis C virus (HCV) variants, existing recombinant HCV replication models have failed to be effective in developing effective anti-HCV agents. In the current study, we describe an in vitro system that supports the infection and replication of natural HCV from patient blood using an immortalized primary human hepatocyte cell line cultured in a three-dimensional (3D) culture system. Comparison of the gene expression profile of cells cultured in the 3D system to those cultured in the existing 2D system demonstrated an up-regulation of several genes activated by peroxisome proliferator-activated receptor alpha (PPAR{alpha}) signaling. Furthermore,more » using PPAR{alpha} agonists and antagonists, we also analyzed the effect of PPAR{alpha} signaling on the modulation of HCV replication using this system. The 3D in vitro system described in this study provides significant insight into the search for novel anti-HCV strategies that are specific to various strains of HCV.« less

  14. Procalcitonin levels in patients with positive blood culture, positive body fluid culture, sepsis, and severe sepsis: a cross-sectional study.

    PubMed

    Yu, Ying; Li, Xia-Xi; Jiang, Ling-Xiao; Du, Meng; Liu, Zhan-Guo; Cen, Zhong-Ran; Wang, Hua; Guo, Zhen-Hui; Chang, Ping

    2016-01-01

    Numerous investigations on procalcitonin (PCT) have been carried out, although few with large sample size. To deal with the complexity of sepsis, an understanding of PCT in heterogeneous clinical conditions is required. Hospitalized patients aged 10-79 years were included in this retrospective and cross-sectional study. PCT tests were assayed within 2 days of blood culture. A total of 2952 cases (from 2538 patients) were enrolled in this study, including 440 cases in the 'positive BC' group, 123 cases in the 'positive body fluid culture' group, and 2389 cases in the 'negative all culture' group. Median PCT values were 4.53 ng/ml, 2.95 ng/ml, and 0.49 ng/ml, respectively. Median PCT values in the gram-negative BC group and gram-positive BC group, respectively, were 6.99 ng/ml and 2.96 ng/ml. Median PCT values in the 'positive hydrothorax culture' group, 'positive ascites culture' group, 'positive bile culture' group, and 'positive cerebrospinal fluid culture' group, respectively, were 1.39 ng/ml, 8.32 ng/ml, 5.98 ng/ml, and 0.46 ng/ml. In all, 357 cases were classified into the 'sepsis' group, 150 of them were classified into the 'severe sepsis' group. Median PCT values were 5.63 ng/ml and 11.06 ng/ml, respectively. PCT could be used in clinical algorithms to diagnose positive infections and sepsis. Different PCT levels could be related to different kinds of microbemia, different infection sites, and differing severity of sepsis.

  15. Comparison of methods for the identification of microorganisms isolated from blood cultures.

    PubMed

    Monteiro, Aydir Cecília Marinho; Fortaleza, Carlos Magno Castelo Branco; Ferreira, Adriano Martison; Cavalcante, Ricardo de Souza; Mondelli, Alessandro Lia; Bagagli, Eduardo; da Cunha, Maria de Lourdes Ribeiro de Souza

    2016-08-05

    Bloodstream infections are responsible for thousands of deaths each year. The rapid identification of the microorganisms causing these infections permits correct therapeutic management that will improve the prognosis of the patient. In an attempt to reduce the time spent on this step, microorganism identification devices have been developed, including the VITEK(®) 2 system, which is currently used in routine clinical microbiology laboratories. This study evaluated the accuracy of the VITEK(®) 2 system in the identification of 400 microorganisms isolated from blood cultures and compared the results to those obtained with conventional phenotypic and genotypic methods. In parallel to the phenotypic identification methods, the DNA of these microorganisms was extracted directly from the blood culture bottles for genotypic identification by the polymerase chain reaction (PCR) and DNA sequencing. The automated VITEK(®) 2 system correctly identified 94.7 % (379/400) of the isolates. The YST and GN cards resulted in 100 % correct identifications of yeasts (15/15) and Gram-negative bacilli (165/165), respectively. The GP card correctly identified 92.6 % (199/215) of Gram-positive cocci, while the ANC card was unable to correctly identify any Gram-positive bacilli (0/5). The performance of the VITEK(®) 2 system was considered acceptable and statistical analysis showed that the system is a suitable option for routine clinical microbiology laboratories to identify different microorganisms.

  16. A Novel Stopped-Flow Assay for Quantitating Carbonic-Anhydrase Activity and Assessing Red-Blood-Cell Hemolysis.

    PubMed

    Zhao, Pan; Geyer, R Ryan; Boron, Walter F

    2017-01-01

    We report a novel carbonic-anhydrase (CA) assay and its use for quantitating red-blood-cell (RBC) lysis during stopped-flow (SF) experiments. We combine two saline solutions, one containing HEPES/pH 7.03 and the other, ~1% CO 2 /44 mM [Formula: see text]/pH 8.41, to generate an out-of-equilibrium CO 2 /[Formula: see text] solution containing ~0.5% CO 2 /22 [Formula: see text]/pH ~7.25 (10°C) in the SF reaction cell. CA catalyzes relaxation of extracellular pH to ~7.50: [Formula: see text] + H + → CO 2 + H 2 O. Proof-of-concept studies (no intact RBCs) show that the pH-relaxation rate constant ( k ΔpH )-measured via pyranine fluorescence-rises linearly with increases in [bovine CAII] or [murine-RBC lysate]. The y-intercept (no CA) was k ΔpH = 0.0183 s -1 . Combining increasing amounts of murine-RBC lysate with ostensibly intact RBCs (pre-SF hemolysis ≅0.4%)-fixing total [hemoglobin] at 2.5 μM in the reaction cell to simulate hemolysis from ostensibly 0 to 100%-causes k ΔpH to increase linearly. This y-intercept (0% lysate/100% ostensibly intact RBCs) was k ΔpH = 0.0820 s -1 , and the maximal k ΔpH (100% lysate/0% intact RBCs) was 1.304 s -1 . Thus, mean percent hemolysis in the reaction cell was ~4.9%. Phenol-red absorbance assays yield indistinguishable results. The increase from 0.4 to 4.9% presumably reflects mechanical RBC disruption during rapid mixing. In all fluorescence studies, the CA blocker acetazolamide reduces k ΔpH to near-uncatalyzed values, implying that all CA activity is extracellular. Our lysis assay is simple, sensitive, and precise, and will be valuable for correcting for effects of lysis in physiological SF experiments. The underlying CA assay, applied to blood plasma, tissue-culture media, and organ perfusates could assess lysis in a variety of applications.

  17. A Novel Stopped-Flow Assay for Quantitating Carbonic-Anhydrase Activity and Assessing Red-Blood-Cell Hemolysis

    PubMed Central

    Zhao, Pan; Geyer, R. Ryan; Boron, Walter F.

    2017-01-01

    We report a novel carbonic-anhydrase (CA) assay and its use for quantitating red-blood-cell (RBC) lysis during stopped-flow (SF) experiments. We combine two saline solutions, one containing HEPES/pH 7.03 and the other, ~1% CO2/44 mM HCO3-/pH 8.41, to generate an out-of-equilibrium CO2/HCO3- solution containing ~0.5% CO2/22 HCO3-/pH ~7.25 (10°C) in the SF reaction cell. CA catalyzes relaxation of extracellular pH to ~7.50: HCO3- + H+ → CO2 + H2O. Proof-of-concept studies (no intact RBCs) show that the pH-relaxation rate constant (kΔpH)—measured via pyranine fluorescence—rises linearly with increases in [bovine CAII] or [murine-RBC lysate]. The y-intercept (no CA) was kΔpH = 0.0183 s−1. Combining increasing amounts of murine-RBC lysate with ostensibly intact RBCs (pre-SF hemolysis ≅0.4%)—fixing total [hemoglobin] at 2.5 μM in the reaction cell to simulate hemolysis from ostensibly 0 to 100%—causes kΔpH to increase linearly. This y-intercept (0% lysate/100% ostensibly intact RBCs) was kΔpH = 0.0820 s−1, and the maximal kΔpH (100% lysate/0% intact RBCs) was 1.304 s−1. Thus, mean percent hemolysis in the reaction cell was ~4.9%. Phenol-red absorbance assays yield indistinguishable results. The increase from 0.4 to 4.9% presumably reflects mechanical RBC disruption during rapid mixing. In all fluorescence studies, the CA blocker acetazolamide reduces kΔpH to near-uncatalyzed values, implying that all CA activity is extracellular. Our lysis assay is simple, sensitive, and precise, and will be valuable for correcting for effects of lysis in physiological SF experiments. The underlying CA assay, applied to blood plasma, tissue-culture media, and organ perfusates could assess lysis in a variety of applications. PMID:28400735

  18. Integration of Quantitative Positron Emission Tomography Absolute Myocardial Blood Flow Measurements in the Clinical Management of Coronary Artery Disease.

    PubMed

    Gewirtz, Henry; Dilsizian, Vasken

    2016-05-31

    In the >40 years since planar myocardial imaging with(43)K-potassium was introduced into clinical research and management of patients with coronary artery disease (CAD), diagnosis and treatment have undergone profound scientific and technological changes. One such innovation is the current state-of-the-art hardware and software for positron emission tomography myocardial perfusion imaging, which has advanced it from a strictly research-oriented modality to a clinically valuable tool. This review traces the evolving role of quantitative positron emission tomography measurements of myocardial blood flow in the evaluation and management of patients with CAD. It presents methodology, currently or soon to be available, that offers a paradigm shift in CAD management. Heretofore, radionuclide myocardial perfusion imaging has been primarily qualitative or at best semiquantitative in nature, assessing regional perfusion in relative terms. Thus, unlike so many facets of modern cardiovascular practice and CAD management, which depend, for example, on absolute values of key parameters such as arterial and left ventricular pressures, serum lipoprotein, and other biomarker levels, the absolute levels of rest and maximal myocardial blood flow have yet to be incorporated into routine clinical practice even in most positron emission tomography centers where the potential to do so exists. Accordingly, this review focuses on potential value added for improving clinical CAD practice by measuring the absolute level of rest and maximal myocardial blood flow. Physiological principles and imaging fundamentals necessary to understand how positron emission tomography makes robust, quantitative measurements of myocardial blood flow possible are highlighted. © 2016 American Heart Association, Inc.

  19. Re-using blood products as an alternative supplement in the optimisation of clinical-grade adipose-derived mesenchymal stem cell culture

    PubMed Central

    Phetfong, J.; Tawonsawatruk, T.; Seenprachawong, K.; Srisarin, A.; Isarankura-Na-Ayudhya, C.

    2017-01-01

    Objectives Adipose-derived mesenchymal stem cells (ADMSCs) are a promising strategy for orthopaedic applications, particularly in bone repair. Ex vivo expansion of ADMSCs is required to obtain sufficient cell numbers. Xenogenic supplements should be avoided in order to minimise the risk of infections and immunological reactions. Human platelet lysate and human plasma may be an excellent material source for ADMSC expansion. In the present study, use of blood products after their recommended transfusion date to prepare human platelet lysate (HPL) and human plasma (Hplasma) was evaluated for in vitro culture expansion and osteogenesis of ADMSCs. Methods Human ADMSCs were cultured in medium supplemented with HPL, Hplasma and a combination of HPL and Hplasma (HPL+Hplasma). Characteristics of these ADMSCs, including osteogenesis, were evaluated in comparison with those cultured in fetal bovine serum (FBS). Results HPL and HPL+Hplasma had a significantly greater growth-promoting effect than FBS, while Hplasma exhibited a similar growth-promoting effect to that of FBS. ADMSCs cultured in HPL and/or Hplasma generated more colony-forming unit fibroblasts (CFU-F) than those cultured in FBS. After long-term culture, ADMSCs cultured in HPL and/or Hplasma showed reduced cellular senescence, retained typical cell phenotypes, and retained differentiation capacities into osteogenic and adipogenic lineages. Conclusion HPL and Hplasma prepared from blood products after their recommended transfusion date can be used as an alternative and effective source for large-scale ex vivo expansion of ADMSCs. Cite this article: J. Phetfong, T. Tawonsawatruk, K. Seenprachawong, A. Srisarin, C. Isarankura-Na-Ayudhya, A. Supokawej. Re-using blood products as an alternative supplement in the optimisation of clinical-grade adipose-derived mesenchymal stem cell culture. Bone Joint Res 2017;6:414–422. DOI: 10.1302/2046-3758.67.BJR-2016-0342.R1. PMID:28720606

  20. Isolation of Francisella tularensis and Yersinia pestis from Blood Cultures by Plasma Purification and Immunomagnetic Separation Accelerates Antibiotic Susceptibility Determination

    PubMed Central

    Aloni-Grinstein, Ronit; Schuster, Ofir; Yitzhaki, Shmuel; Aftalion, Moshe; Maoz, Sharon; Steinberger-Levy, Ida; Ber, Raphael

    2017-01-01

    The early symptoms of tularemia and plague, which are caused by Francisella tularensis and Yersinia pestis infection, respectively, are common to other illnesses, resulting in a low index of suspicion among clinicians. Moreover, because these diseases can be treated only with antibiotics, rapid isolation of the bacteria and antibiotic susceptibility testing (AST) are preferable. Blood cultures of patients may serve as a source for bacteria isolation. However, due to the slow growth rates of F. tularensis and Y. pestis on solid media, isolation by plating blood culture samples on proper agar plates may require several days. Thus, improving the isolation procedure prior to antibiotic susceptibility determination is a major clinically relevant need. In this study, we developed a rapid, selective procedure for the isolation of F. tularensis and Y. pestis from blood cultures. We examined drop-plating and plasma purification followed by immunomagnetic separation (IMS) as alternative isolation methods. We determined that replacing the classical isolation method with drop-plating is advantageous with respect to time at the expense of specificity. Hence, we also examined isolation by IMS. Sub-localization of F. tularensis within blood cultures of infected mice has revealed that the majority of the bacteria are located within the extracellular fraction, in the plasma. Y. pestis also resides within the plasma. Therefore, the plasma fraction was isolated from blood cultures and subjected to an IMS procedure using polyclonal anti-F. tularensis live vaccine strain (LVS) or anti-Y. pestis antibodies conjugated to 50-nm nano-beads. The time required to reach an inoculum of sufficient bacteria for AST was shortest when using the plasma and IMSs for both bacteria, saving up to 2 days of incubation for F. tularensis and 1 day for Y. pestis. Our isolation procedure provides a proof of concept for the clinical relevance of rapid isolation for AST from F. tularensis- and Y. pestis

  1. Rapid identification of pathogens directly from blood culture bottles by Bruker matrix-assisted laser desorption laser ionization-time of flight mass spectrometry versus routine methods.

    PubMed

    Jamal, Wafaa; Saleem, Rola; Rotimi, Vincent O

    2013-08-01

    The use of matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) for identification of microorganisms directly from blood culture is an exciting dimension to the microbiologists. We evaluated the performance of Bruker SepsiTyper kit™ (STK) for direct identification of bacteria from positive blood culture. This was done in parallel with conventional methods. Nonrepetitive positive blood cultures from 160 consecutive patients were prospectively evaluated by both methods. Of 160 positive blood cultures, the STK identified 114 (75.6%) isolates and routine conventional method 150 (93%). Thirty-six isolates were misidentified or not identified by the kit. Of these, 5 had score of >2.000 and 31 had an unreliable low score of <1.7. Four of 8 yeasts were identified correctly. The average turnaround time using the STK was 35 min, including extraction steps and 30:12 to 36:12 h with routine method. The STK holds promise for timely management of bacteremic patients. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. TOWARD QUANTITATIVE OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY: Visualizing Blood Flow Speeds in Ocular Pathology Using Variable Interscan Time Analysis.

    PubMed

    Ploner, Stefan B; Moult, Eric M; Choi, WooJhon; Waheed, Nadia K; Lee, ByungKun; Novais, Eduardo A; Cole, Emily D; Potsaid, Benjamin; Husvogt, Lennart; Schottenhamml, Julia; Maier, Andreas; Rosenfeld, Philip J; Duker, Jay S; Hornegger, Joachim; Fujimoto, James G

    2016-12-01

    Currently available optical coherence tomography angiography systems provide information about blood flux but only limited information about blood flow speed. The authors develop a method for mapping the previously proposed variable interscan time analysis (VISTA) algorithm into a color display that encodes relative blood flow speed. Optical coherence tomography angiography was performed with a 1,050 nm, 400 kHz A-scan rate, swept source optical coherence tomography system using a 5 repeated B-scan protocol. Variable interscan time analysis was used to compute the optical coherence tomography angiography signal from B-scan pairs having 1.5 millisecond and 3.0 milliseconds interscan times. The resulting VISTA data were then mapped to a color space for display. The authors evaluated the VISTA visualization algorithm in normal eyes (n = 2), nonproliferative diabetic retinopathy eyes (n = 6), proliferative diabetic retinopathy eyes (n = 3), geographic atrophy eyes (n = 4), and exudative age-related macular degeneration eyes (n = 2). All eyes showed blood flow speed variations, and all eyes with pathology showed abnormal blood flow speeds compared with controls. The authors developed a novel method for mapping VISTA into a color display, allowing visualization of relative blood flow speeds. The method was found useful, in a small case series, for visualizing blood flow speeds in a variety of ocular diseases and serves as a step toward quantitative optical coherence tomography angiography.

  3. Comparison of blood flow models and acquisitions for quantitative myocardial perfusion estimation from dynamic CT

    NASA Astrophysics Data System (ADS)

    Bindschadler, Michael; Modgil, Dimple; Branch, Kelley R.; La Riviere, Patrick J.; Alessio, Adam M.

    2014-04-01

    Myocardial blood flow (MBF) can be estimated from dynamic contrast enhanced (DCE) cardiac CT acquisitions, leading to quantitative assessment of regional perfusion. The need for low radiation dose and the lack of consensus on MBF estimation methods motivates this study to refine the selection of acquisition protocols and models for CT-derived MBF. DCE cardiac CT acquisitions were simulated for a range of flow states (MBF = 0.5, 1, 2, 3 ml (min g)-1, cardiac output = 3, 5, 8 L min-1). Patient kinetics were generated by a mathematical model of iodine exchange incorporating numerous physiological features including heterogenenous microvascular flow, permeability and capillary contrast gradients. CT acquisitions were simulated for multiple realizations of realistic x-ray flux levels. CT acquisitions that reduce radiation exposure were implemented by varying both temporal sampling (1, 2, and 3 s sampling intervals) and tube currents (140, 70, and 25 mAs). For all acquisitions, we compared three quantitative MBF estimation methods (two-compartment model, an axially-distributed model, and the adiabatic approximation to the tissue homogeneous model) and a qualitative slope-based method. In total, over 11 000 time attenuation curves were used to evaluate MBF estimation in multiple patient and imaging scenarios. After iodine-based beam hardening correction, the slope method consistently underestimated flow by on average 47.5% and the quantitative models provided estimates with less than 6.5% average bias and increasing variance with increasing dose reductions. The three quantitative models performed equally well, offering estimates with essentially identical root mean squared error (RMSE) for matched acquisitions. MBF estimates using the qualitative slope method were inferior in terms of bias and RMSE compared to the quantitative methods. MBF estimate error was equal at matched dose reductions for all quantitative methods and range of techniques evaluated. This suggests that

  4. Whole Blood Activation Results in Enhanced Detection of T Cell and Monocyte Cytokine Production by Flow Cytometry

    NASA Technical Reports Server (NTRS)

    Sams, Clarence F.; Crucian, Brian E.

    2001-01-01

    An excellent monitor of the immune balance of peripheral circulating cells is to determine their cytokine production patterns in response to stimuli. Using flow cytometry a positive identification of cytokine producing cells in a mixed culture may be achieved. Recently, the ability to assess cytokine production following a wholeblood activation culture has been described. We compared whole blood culture to standard PBMC culture and determined the individual cytokine secretion patterns for both T cells and monocytes via flow cytometry. For T cells cytokine assessment following PMA +ionomycin activation: (1) a significantly greater percentages of T cells producing IFNgamma and IL-2 were observed following whole-blood culture; (2) altered T cell cytokine production kinetics were observed by varying whole blood culture times. In addition, a four-color cytometric analysis was used to allow accurate phenotyping and quantitation of cytokine producing lymphocyte populations. Using this technique we found IFNgamma production to be significantly elevated in the CD3+/CD8+ T cell population as compared to the CD3+/CD8- population following five hours of whole blood activation. Conversely, IL-2 and IL-10 production were significantly elevated in the CD3+/CD8- T cell population as compared to the CD3+/CD8+ population. Monocyte cytokine production was assessed in both culture systems following LPS activation for 24 hours. A three-color flow cytometric was used to assess two cytokines in conjunction with CD 14. The cytokine pairs used for analysis were IL-1a/IL-12, and IL-10ITNFa. Nearly all monocytes were stimulated to produce IL-1a, IL-12 and TNFalpha equally well in both culture systems. Monocyte production of IL-10 was significantly elevated following whole blood culture as compared to PBMC culture. IL-12 producing monocytes appeared to be a distinct subpopulation of the IL-1a producing set, whereas IL-10 and TNFa producing monocytes were largely mutually exclusive. IL-10 and

  5. Identification and susceptibility testing of microorganism by direct inoculation from positive blood culture bottles by combining MALDI-TOF and Vitek-2 Compact is rapid and effective.

    PubMed

    Romero-Gómez, María-Pilar; Gómez-Gil, Rosa; Paño-Pardo, Jose Ramón; Mingorance, Jesús

    2012-12-01

    The objective of this study was to evaluate the reliability and accuracy of the combined use of MALDI-TOF MS bacterial identification and the Vitek-2 Compact antimicrobial susceptibility testing (AST) directly from positive blood cultures. Direct identification by MALDI-TOF MS and AST were performed in parallel to the standard methods in all positively flagged blood cultures bottles during the study period. Three hundred and twenty four monomicrobial positive blood cultures were included in the present study, with 257 Gram-negative and 67 Gram-positive isolates. MALDI-TOF MS identification directly from blood bottles reported the correct identification for Enterobacteriaceae in 97.7%, non-fermentative Gram-negative bacilli 75.0%, Staphylococcus aureus 75.8%, coagulase negative staphylococci 63.3% and enterococci 63.3%. A total 6156 isolate/antimicrobial agent combinations were tested. Enterobacteriaceae group and non-fermentative Gram-negative Bacilli showed an agreement of 96.67% and 92.30%, respectively, for the Gram-positive cocci the overall agreement found was 97.84%. We conclude that direct identification by MALDI-TOF and inoculation of Vitek-2 Compact AST with positive blood culture bottles yielded very good results and decreased time between initial inoculation of blood culture media and determination of the antibiotic susceptibility for Gram-negative rods and Gram-positive cocci causing bacteremia. Copyright © 2012 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  6. An eight-year review of blood culture and susceptibility among sepsis cases in an emergency department in Northeastern Malaysia.

    PubMed

    Hashairi, F; Hasan, H; Azlan, K; Deris, Z Z

    2011-12-01

    An understanding of common pathogens and their antibiotic sensitivity patterns is critical for proper management of sepsis in Emergency Department (ED). The goal of the study was to identify common organisms isolated from blood cultures of patients attended to ED and their antimicrobial susceptibility. Beginning from 2002, all cases of positive blood culture collected by the ED, Hospital Universiti Sains Malaysia (HUSM) were recorded and analysed. Over the period of eight years, we documented 995 cases of positive blood cultures. Of these samples, 549 (55.2%) were Gram-negative bacteria; 419 (42.1%) were Gram-positive bacteria; 10 (1.0%) were anaerobic organisms; 10 (1.0%) were fungus; and 7 (0.7%) cases were mixed organisms. Gram-negative bacteria were observed to develop more resistance to antimicrobial agents, especially those commonly used in an outpatient setting with less than 80% sensitivity to ampicillin, cotrimoxazole and ciprofloxacin. By contrast, there has been no marked change in the sensitivity trends of Gram-positive bacteria over the same period. In conclusion, ED physicians are more equipped to initiate empirical antimicrobial therapy especially when dealing with possibility of Gram-negative sepsis.

  7. Rapid Identification of Microorganisms from Positive Blood Culture by MALDI-TOF MS After Short-Term Incubation on Solid Medium.

    PubMed

    Curtoni, Antonio; Cipriani, Raffaella; Marra, Elisa Simona; Barbui, Anna Maria; Cavallo, Rossana; Costa, Cristina

    2017-01-01

    Matrix-assisted laser-desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) is a useful tool for rapid identification of microorganisms. Unfortunately, its direct application to positive blood culture is still lacking standardized procedures. In this study, we evaluated an easy- and rapid-to-perform protocol for MALDI-TOF MS direct identification of microorganisms from positive blood culture after a short-term incubation on solid medium. This protocol was used to evaluate direct identification of microorganisms from 162 positive monomicrobial blood cultures; at different incubation times (3, 5, 24 h), MALDI-TOF MS assay was performed from the growing microorganism patina. Overall, MALDI-TOF MS concordance with conventional methods at species level was 60.5, 80.2, and 93.8% at 3, 5, and 24 h, respectively. Considering only bacteria, the identification performances at species level were 64.1, 85.0, and 94.1% at 3, 5, and 24 h, respectively. This protocol applied to a commercially available MS typing system may represent, a fast and powerful diagnostic tool for pathogen direct identification and for a promptly and pathogen-driven antimicrobial therapy in selected cases.

  8. Why the dish makes a difference: quantitative comparison of polystyrene culture surfaces.

    PubMed

    Zeiger, Adam S; Hinton, Benjamin; Van Vliet, Krystyn J

    2013-07-01

    There is wide anecdotal recognition that biological cell viability and behavior can vary significantly as a function of the source of commercial tissue culture polystyrene (TCPS) culture vessels to which those cells adhere. However, this marked material dependency is typically resolved by selecting and then consistently using the same manufacturer's product - following protocol - rather than by investigating the material properties that may be responsible for such experimental variation. Here, we quantified several physical properties of TCPS surfaces obtained from a wide range of commercial sources and processing steps, through the use of atomic force microscopy (AFM)-based imaging and analysis, goniometry and protein adsorption quantification. We identify qualitative differences in surface features, as well as quantitative differences in surface roughness and wettability that cannot be attributed solely to differences in surface chemistry. We also find significant differences in cell morphology and proliferation among cells cultured on different TCPS surfaces, and resolve a correlation between nanoscale surface roughness and cell proliferation rate for both cell types considered. Interestingly, AFM images of living adherent cells on these nanotextured surfaces demonstrate direct interactions between cellular protrusions and topographically distinct features. These results illustrate and quantify the significant differences in material surface properties among these ubiquitous materials, allowing us to better understand why the dish can make a difference in biological experiments. Copyright © 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  9. Isolation of Corynebacterium tuscaniae sp. nov. from Blood Cultures of a Patient with Endocarditis

    PubMed Central

    Riegel, Philippe; Creti, Roberta; Mattei, Romano; Nieri, Alfredo; von Hunolstein, Christina

    2006-01-01

    A strain of an unknown coryneform bacterium was repeatedly isolated in pure culture from the blood of a patient affected by endocarditis. Comparative 16S rRNA gene sequence analysis revealed that this isolate represented a new subline within the genus Corynebacterium. This new taxon can be identified by the presence of corynomycolic acids and its enzymatic activities and fermentation of sugars. Acid production from glucose and maltose, pyrazinamidase and alkaline phoshatase activities, and hippurate hydrolysis were the most characteristic phenotypic features of the bacterium. On the basis of both phenotypic and phylogenetic evidence, it is proposed that this isolate be classified as a novel species, Corynebacterium tuscaniae sp. nov. The type strain, ISS-5309, has been deposited in the American Type Culture Collection (ATCC BAA-1141) and in the Culture Collection of the University of Göteborg (CCUG 51321). PMID:16455875

  10. The quantitative measurement of organizational culture in health care: a review of the available instruments.

    PubMed

    Scott, Tim; Mannion, Russell; Davies, Huw; Marshall, Martin

    2003-06-01

    To review the quantitative instruments available to health service researchers who want to measure culture and cultural change. A literature search was conducted using Medline, Cinahl, Helmis, Psychlit, Dhdata, and the database of the King's Fund in London for articles published up to June 2001, using the phrase "organizational culture." In addition, all citations and the gray literature were reviewed and advice was sought from experts in the field to identify instruments not found on the electronic databases. The search focused on instruments used to quantify culture with a track record, or potential for use, in health care settings. For each instrument we examined the cultural dimensions addressed, the number of items for each questionnaire, the measurement scale adopted, examples of studies that had used the tool, the scientific properties of the instrument, and its strengths and limitations. Thirteen instruments were found that satisfied our inclusion criteria, of which nine have a track record in studies involving health care organizations. The instruments varied considerably in terms of their grounding in theory, format, length, scope, and scientific properties. A range of instruments with differing characteristics are available to researchers interested in organizational culture, all of which have limitations in terms of their scope, ease of use, or scientific properties. The choice of instrument should be determined by how organizational culture is conceptualized by the research team, the purpose of the investigation, intended use of the results, and availability of resources.

  11. Rapid Detection of Staphylococcus aureus and Methicillin-Resistant S. aureus (MRSA) in Wound Specimens and Blood Cultures: Multicenter Preclinical Evaluation of the Cepheid Xpert MRSA/SA Skin and Soft Tissue and Blood Culture Assays▿

    PubMed Central

    Wolk, D. M.; Struelens, M. J.; Pancholi, P.; Davis, T.; Della-Latta, P.; Fuller, D.; Picton, E.; Dickenson, R.; Denis, O.; Johnson, D.; Chapin, K.

    2009-01-01

    A multicenter preclinical evaluation was conducted to evaluate the performance of two Cepheid Xpert assays for detection of methicillin-resistant Staphylococcus aureus (MRSA) and S. aureus. Sensitivity was 97.1% and 98.3% for MRSA in wound and blood culture specimens, respectively. Sensitivity was 100% for S. aureus from both specimen types. PMID:19144803

  12. [Gas chromatography in quantitative analysis of hydrocyanic acid and its salts in cadaveric blood].

    PubMed

    Iablochkin, V D

    2003-01-01

    A direct gas chromatography method was designed for the quantitative determination of cyanides (prussic acid) in cadaveric blood. Its sensitivity is 0.05 mg/ml. The routine volatile products, including substances, which emerge due to putrefaction of organic matters, do not affect the accuracy and reproducibility of the method; the exception is H-propanol that was used as the internal standard. The method was used in legal chemical expertise related with acute cyanide poisoning (suicide) as well as with poisoning of products of combustion of nonmetals (foam-rubber). The absolute error does not exceed 10% with a mean quadratic deviation of 0.0029-0.0033 mg.

  13. Nanomechanical sensor applied to blood culture pellets: a fast approach to determine the antibiotic susceptibility against agents of bloodstream infections.

    PubMed

    Stupar, P; Opota, O; Longo, G; Prod'hom, G; Dietler, G; Greub, G; Kasas, S

    2017-06-01

    The management of bloodstream infection, a life-threatening disease, largely relies on early detection of infecting microorganisms and accurate determination of their antibiotic susceptibility to reduce both mortality and morbidity. Recently we developed a new technique based on atomic force microscopy capable of detecting movements of biologic samples at the nanoscale. Such sensor is able to monitor the response of bacteria to antibiotic's pressure, allowing a fast and versatile susceptibility test. Furthermore, rapid preparation of a bacterial pellet from a positive blood culture can improve downstream characterization of the recovered pathogen as a result of the increased bacterial concentration obtained. Using artificially inoculated blood cultures, we combined these two innovative procedures and validated them in double-blind experiments to determine the susceptibility and resistance of Escherichia coli strains (ATCC 25933 as susceptible and a characterized clinical isolate as resistant strain) towards a selection of antibiotics commonly used in clinical settings. On the basis of the variance of the sensor movements, we were able to positively discriminate the resistant from the susceptible E. coli strains in 16 of 17 blindly investigated cases. Furthermore, we defined a variance change threshold of 60% that discriminates susceptible from resistant strains. By combining the nanomotion sensor with the rapid preparation method of blood culture pellets, we obtained an innovative, rapid and relatively accurate method for antibiotic susceptibility test directly from positive blood culture bottles, without the need for bacterial subculture. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  14. Dynamic quantitative photothermal monitoring of cell death of individual human red blood cells upon glucose depletion

    NASA Astrophysics Data System (ADS)

    Vasudevan, Srivathsan; Chen, George Chung Kit; Andika, Marta; Agarwal, Shuchi; Chen, Peng; Olivo, Malini

    2010-09-01

    Red blood cells (RBCs) have been found to undergo ``programmed cell death,'' or eryptosis, and understanding this process can provide more information about apoptosis of nucleated cells. Photothermal (PT) response, a label-free photothermal noninvasive technique, is proposed as a tool to monitor the cell death process of living human RBCs upon glucose depletion. Since the physiological status of the dying cells is highly sensitive to photothermal parameters (e.g., thermal diffusivity, absorption, etc.), we applied linear PT response to continuously monitor the death mechanism of RBC when depleted of glucose. The kinetics of the assay where the cell's PT response transforms from linear to nonlinear regime is reported. In addition, quantitative monitoring was performed by extracting the relevant photothermal parameters from the PT response. Twofold increases in thermal diffusivity and size reduction were found in the linear PT response during cell death. Our results reveal that photothermal parameters change earlier than phosphatidylserine externalization (used for fluorescent studies), allowing us to detect the initial stage of eryptosis in a quantitative manner. Hence, the proposed tool, in addition to detection of eryptosis earlier than fluorescence, could also reveal physiological status of the cells through quantitative photothermal parameter extraction.

  15. Photodynamic inactivation of contaminated blood with Staphylococcus aureus

    NASA Astrophysics Data System (ADS)

    Corrêa, Thaila Q.; Inada, Natalia M.; Pratavieira, Sebastião.; Blanco, Kate C.; Kurachi, Cristina; Bagnato, Vanderlei S.

    2016-03-01

    The presence of bacteria in the bloodstream can trigger a serious systemic inflammation and lead to sepsis that cause septic shock and death. Studies have shown an increase in the incidence of sepsis over the years and it is mainly due to the increased resistance of microorganisms to antibiotics, since these drugs are still sold and used improperly. The bacterial contamination of blood is also a risk to blood transfusions. Thus, bacteria inactivation in blood is being studied in order to increase the security of the blood supply. The purpose of this study was to decontaminate the blood using the photodynamic inactivation (PDI). Human blood samples in the presence of Photogem® were illuminated at an intensity of 30 mW/cm2, and light doses of 10 and 15 J/cm2. Blood counts were carried out for the quantitative evaluation and blood smears were prepared for qualitative and morphological evaluation by microscopy. The results showed normal viability values for the blood cells analyzed. The light doses showed minimal morphological changes in the membrane of red blood cells, but the irradiation in the presence of the photosensitizer caused hemolysis in red blood cells at the higher concentrations of the photosensitizer. Experiments with Staphylococcus aureus, one of the responsible of sepsis, showed 7 logs10 of photodynamic inactivation with 50 μg/mL and 15 J/cm2 and 1 log10 of this microorganism in a co-culture with blood.

  16. Nanobacteria from blood: the smallest culturable autonomously replicating agent on Earth

    NASA Astrophysics Data System (ADS)

    Kajander, E. Olavi; Kuronen, Ilpo; Akerman, Kari K.; Pelttari, Alpo; Ciftcioglu, Neva

    1997-07-01

    Nanobacteria are the first mineral forming bacteria isolated from blood and blood products. They are coccoid cell-walled organisms with a size of 0.08 - 0.5 micrometers in EM, occure in clusters, produce a biofilm containing carbonate or hydroxyl apatite, and are highly resistant to heat, gamma-irradiation and antibiotics. Their growth rate is about one hundredth that of ordinary bacteria and they divide via several mechanisms. Taq polymerase was able to use their nontraditional nucleic acid as a template. 16S rRNA gene sequence results positioned them into the alpha-2 subgroup of Proteobacteria. Nanobacteria are smallest cell-walled bacteria since they can pass through 0.07 micrometers pores. In low-serum cultures, they form even smaller elementary particles or tubular units. How can blood be infected with such slow growing, heat and radio-resistant bacteria? The answer may lie in their phylogeny: alpha-2 subgroup has organisms from soil exposed to radiation and heat, that can penetrate into eukaryotic cells. Nanobacteria grow so slowly that they require a niche `cleaned' with heat, radiation or immunodefence. For survival they cloak themselves in apatite, a normal constituent of mammalian body. This may link nanobacteria to nannobacteria discovered from sedimentary rocks by Dr. Folk. Both have similar size, size variation, clustering and mineral deposits. They may resemble the probable ancient bacterial fossils in the Martian meteorite ALH84001.

  17. Automated high resolution full-field spatial coherence tomography for quantitative phase imaging of human red blood cells

    NASA Astrophysics Data System (ADS)

    Singla, Neeru; Dubey, Kavita; Srivastava, Vishal; Ahmad, Azeem; Mehta, D. S.

    2018-02-01

    We developed an automated high-resolution full-field spatial coherence tomography (FF-SCT) microscope for quantitative phase imaging that is based on the spatial, rather than the temporal, coherence gating. The Red and Green color laser light was used for finding the quantitative phase images of unstained human red blood cells (RBCs). This study uses morphological parameters of unstained RBCs phase images to distinguish between normal and infected cells. We recorded the single interferogram by a FF-SCT microscope for red and green color wavelength and average the two phase images to further reduced the noise artifacts. In order to characterize anemia infected from normal cells different morphological features were extracted and these features were used to train machine learning ensemble model to classify RBCs with high accuracy.

  18. An in-house assay is superior to Sepsityper for direct matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry identification of yeast species in blood cultures.

    PubMed

    Bidart, Marie; Bonnet, Isabelle; Hennebique, Aurélie; Kherraf, Zine Eddine; Pelloux, Hervé; Berger, François; Cornet, Muriel; Bailly, Sébastien; Maubon, Danièle

    2015-05-01

    We developed an in-house assay for the direct identification, by matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry, of yeasts in blood culture. Sixty-one representative strains from 12 species were analyzed in spiked blood cultures. Our assay accurately identified 95 of 107 (88.8%) positive blood cultures and outperformed the commercial Sepsityper kit (81.7% identification). Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  19. SPECT Myocardial Blood Flow Quantitation Concludes Equivocal Myocardial Perfusion SPECT Studies to Increase Diagnostic Benefits.

    PubMed

    Chen, Lung-Ching; Lin, Chih-Yuan; Chen, Ing-Jou; Ku, Chi-Tai; Chen, Yen-Kung; Hsu, Bailing

    2016-01-01

    Recently, myocardial blood flow quantitation with dynamic SPECT/CT has been reported to enhance the detection of coronary artery disease in human. This advance has created important clinical applications to coronary artery disease diagnosis and management for areas where myocardial perfusion PET tracers are not available. We present 2 clinical cases that undergone a combined test of 1-day rest/dipyridamole-stress dynamic SPECT and ECG-gated myocardial perfusion SPECT scans using an integrated imaging protocol and demonstrate that flow parameters are capable to conclude equivocal myocardial perfusion SPECT studies, therefore increasing diagnostic benefits to add value in making clinical decisions.

  20. Shortened Time to Identify Staphylococcus Species from Blood Cultures and Methicillin Resistance Testing Using CHROMAgar

    PubMed Central

    Chihara, Shingo; Hayden, Mary K.; Minogue-Corbett, Eileen; Singh, Kamaljit

    2009-01-01

    The ability to rapidly differentiate coagulase-negative staphylococcus (CoNS) from Staphylococcus aureus and to determine methicillin resistance is important as it affects the decision to treat empiric antibiotic selection. The objective of this study was to evaluate CHROMagar S. aureus and CHROMagar MRSA (Becton Dickinson) for rapid identification of Staphylococcus spp. directly from blood cultures. Consecutive blood culture bottles (BacT Alert 3D SA and SN, bioMérieux) growing gram-positive cocci in clusters were evaluated. An aliquot was plated onto CHROMagar MRSA (C-MRSA) and CHROMagar S. aureus (C-SA) plates, which were read at 12 to 16 hours. C-SA correctly identified 147/147 S. aureus (100% sensitivity); 2 CoNS were misidentified as S. aureus (98% specificity). C-MRSA correctly identified 74/77 MRSA (96% sensitivity). None of the MSSA isolates grew on C-MRSA (100% specificity). In conclusion, CHROMagar is a rapid and sensitive method to distinguish MRSA, MSSA, and coagulase-negative Staphylococcus and may decrease time of reporting positive results. PMID:20016679

  1. Detection of Legionella pneumophila serogroup 1 in blood cultures from a patient treated with tumor necrosis factor-alpha inhibitor.

    PubMed

    Kaku, Norihito; Yanagihara, Katsunori; Morinaga, Yoshitomo; Sato, Tsuyoshi; Nakashima, Munetoshi; Sakai, Takahiro; Tominaga, Hiroo; Wakigawa, Fumiko; Nagashima, Seiji; Fukuda, Minoru; Hashiguchi, Kohji; Kohno, Shigeru

    2013-02-01

    A 65-year-old man was admitted to our hospital with a temperature of 39.3 °C, cough, sputum, and pharyngeal discomfort that had persisted for 3 days. He had been treated with methotrexate and adalimumab (a tumor necrosis factor-alpha [TNF-α] inhibitor) for rheumatoid arthritis for 2 years, and he had also been treated with S-1 (tegafur, gimeracil, and oteracil potassium) for pancreatic metastasis of gastric cancer for 2 months. Regardless of the underlying pathologies, his general condition was good and he had worked as an electrician until 2 days before admission. However, his appetite had suddenly decreased from the day before admission, and high fever and hypoxia were also evident upon admission. A chest X-ray and computed tomography scan revealed left pleural effusion and consolidation in both lungs. The pneumonia severity index score was 165 and the risk class was V. Accordingly, we started to treat the pneumonia with a combination of levofloxacin and meropenem. Thereafter, we received positive urinary antigen test findings for Legionella pneumophila. After hospitalization, hypoxia was progressed and hypotension was emerged. Despite the application of appropriate antibiotics, vasopressors, and oxygenation, the patient died 8 h after admission. Even after his death, blood cultures were continued to consider the possibility of bacterial co-infection. Although no bacteria were detected from blood cultures, Gimenez staining revealed pink bacteria in blood culture fluids. Subsequent blood fluid culture in selective medium revealed L. pneumophila serogroup 1. Recently, TNF-α inhibitors have been described as a risk factor for Legionnaires' disease. In consideration of the increased frequency of TNF-α inhibitors, we may need to recognize anew that L. pneumophila might be a pathogen of severe community-acquired pneumonia.

  2. Impact of reporting gram stain results from blood culture bottles on the selection of antimicrobial agents.

    PubMed

    Uehara, Yuki; Yagoshi, Michiko; Tanimichi, Yumiko; Yamada, Hiroko; Shimoguchi, Kazuo; Yamamoto, Sachiyo; Yanai, Mitsuru; Kumasaka, Kazunari

    2009-07-01

    We assessed the usefulness of reporting direct blood Gram stain results compared with the results of positive blood cultures in 482 episodes and monitored impact on selection of antimicrobial treatment. We found that the reporting groups "Staphylococcus spp," "Pseudomonas spp and related organisms," and "yeasts" identified in this way matched perfectly with later culture identification. When the report indicated Staphylococcus spp or Pseudomonas spp and related organisms, physicians started or changed antimicrobials suitable for these bacteria more frequently than when "other streptococci" and "family Enterobacteriaceae" were reported (P < .05). Incorrect recognition of Acinetobacter spp as Enterobacteriaceae family is still the most challenging problem in this context. Gram stain results that definitively identify Staphylococcus spp, Pseudomonas spp and related organisms, and yeasts reliably can be rapidly provided by clinical laboratories; this information has a significant impact on early selection of effective antimicrobials. Further investigation is needed to assess the clinical impact of reporting Gram stain results in bacteremia.

  3. Applications of copolymer for rapid identification of bacteria in blood culture broths using matrix-assisted laser desorption ionization time-of-flight mass spectrometry.

    PubMed

    Ashizawa, Kazuho; Murata, Syota; Terada, Takashi; Ito, Daisuke; Bunya, Masaru; Watanabe, Koji; Teruuchi, Yoko; Tsuchida, Sachio; Satoh, Mamoru; Nishimura, Motoi; Matsushita, Kazuyuki; Sugama, Yuji; Nomura, Fumio

    2017-08-01

    Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) can be used to identify pathogens in blood culture samples. However, sample pretreatment is needed for direct identification of microbes in blood culture bottles. Conventional protocols are complex and time-consuming. Therefore, in this study, we developed a method for collecting bacteria using polyallylamine-polystyrene copolymer for application in wastewater treatment technology. Using representative bacterial species Escherichia coli and Staphylococcus capitis, we found that polyallylamine-polystyrene can form visible aggregates with bacteria, which can be identified using MALDI-TOF MS. The processing time of our protocol was as short as 15min. Hemoglobin interference in MALDI spectra analysis was significantly decreased in our method compared with the conventional method. In a preliminary experiment, we evaluated the use of our protocol to identify clinical isolates from blood culture bottles. MALDI-TOF MS-based identification of 17 strains from five bacterial species (E. coli, Klebsiella pneumoniae, Enterococcus faecalis, S. aureus, and S. capitis) collected by our protocol was satisfactory. Prospective large-scale studies are needed to further evaluate the clinical application of this novel and simple method of collecting bacteria in blood culture bottles. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Quantitative differentiation of multiple virus in blood using nanoporous silicon oxide immunosensor and artificial neural network.

    PubMed

    Chakraborty, W; Ray, R; Samanta, N; RoyChaudhuri, C

    2017-12-15

    In spite of the rapid developments in various nanosensor technologies, it still remains challenging to realize a reliable ultrasensitive electrical biosensing platform which will be able to detect multiple viruses in blood simultaneously with a fairly high reproducibility without using secondary labels. In this paper, we have reported quantitative differentiation of Hep-B and Hep-C viruses in blood using nanoporous silicon oxide immunosensor array and artificial neural network (ANN). The peak frequency output (f p ) from the steady state sensitivity characteristics and the first cut off frequency (f c ) from the transient characteristics have been considered as inputs to the multilayer ANN. Implementation of several classifier blocks in the ANN architecture and coupling them with both the sensor chips, functionalized with Hep-B and Hep-C antibodies have enabled the quantification of the viruses with an accuracy of around 95% in the range of 0.04fM-1pM and with an accuracy of around 90% beyond 1pM and within 25nM in blood serum. This is the most sensitive report on multiple virus quantification using label free method. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Integration of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry in blood culture diagnostics: a fast and effective approach.

    PubMed

    Klein, Sabrina; Zimmermann, Stefan; Köhler, Christine; Mischnik, Alexander; Alle, Werner; Bode, Konrad A

    2012-03-01

    Sepsis is a major cause of mortality in hospitalized patients worldwide, with lethality rates ranging from 30 to 70 %. Sepsis is caused by a variety of different pathogens, and rapid diagnosis is of outstanding importance, as early and adequate antimicrobial therapy correlates with positive clinical outcome. In recent years, matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) fingerprinting has become a powerful tool in microbiological diagnostics. The direct identification of micro-organisms in a positive blood culture by MALDI-TOF MS can shorten the diagnostic procedure significantly. Therefore, the aim of the present study was to evaluate whether identification rates could be improved by using the new Sepsityper kit from Bruker Daltonics for direct isolation and identification of bacteria from positive blood cultures by MALDI-TOF MS compared with the use of conventional separator gel columns, and to integrate the MALDI-TOF MS-based identification method into the routine course of blood culture diagnostics in the setting of a microbiological laboratory at a university hospital in Germany. The identification of Gram-negative bacteria by MALDI-TOF MS was significantly better using the Sepsityper kit compared with a separator gel tube-based method (99 and 68 % correct identification, respectively). For Gram-positive bacteria, only 73 % were correctly identified by MALDI-TOF with the Sepsityper kit and 59 % with the separator gel tube assay. A major problem of both methods was the poor identification of Gram-positive grape-like clustered cocci. As differentiation of Staphylococcus aureus from coagulase-negative staphylococci is of clinical importance, a PCR was additionally established that was capable of identifying S. aureus directly from positive blood cultures, thus closing this diagnostic gap. Another benefit of the PCR approach is the possibility of directly detecting the genes responsible for meticillin

  6. Differential fluorescent staining method for detection of bacteria in blood cultures, cerebrospinal fluid and other clinical specimens.

    PubMed

    Fazii, P; Ciancaglini, E; Riario Sforza, G

    2002-05-01

    The aim of this study was to evaluate a differential staining method to distinguish gram-positive from gram-negative bacteria in fluorescence. The method is based on two fluorochromes, one acting in the wavelength of red, i.e. the acridine orange, and another acting in the wavelength of green, i.e. the fluorescein. With this method, gram-positive bacteria appear yellow and gram-negative bacteria appear green. In view of the importance of a rapid aetiological diagnosis in cases of septicaemia, the differential staining method in fluorescence was compared with Gram stain for the detection of bacteria in blood. Of 5,820 blood cultures entered into the study and identified by the Bactec 9120 fluorescent series instrument (Becton Dickinson Europe, France), 774 were positive. Of the 774 positive cultures, 689 yielded only a single organism. The differential staining method in fluorescence detected 626 of the 689 cultures, while Gram stain detected 468. On the basis of these results, the sensitivity of the differential staining method in fluorescence was 90.9%, while that of Gram stain was 67.9%. The difference between the two methods was statistically significant ( P<0.001). The differential fluorescent staining method was more sensitive than Gram stain in the detection of bacteria in blood cultures during the incubation period. This technique provides a rapid, simple and highly sensitive staining method that can be used in conjunction with subculture methods. Whereas subculture requires an incubation period of 18-24 h, the fluorescent staining technique can detect bacteria on the same day that smears are prepared and examined. The differential fluorescent staining method was also evaluated for its ability to detect microorganisms in cerebrospinal fluid and other clinical specimens. The microorganisms were easily detected, even when bacterial counts in the specimens were low.

  7. Oxalic Acid from Lentinula edodes Culture Filtrate: Antimicrobial Activity on Phytopathogenic Bacteria and Qualitative and Quantitative Analyses

    PubMed Central

    Kwak, A-Min; Lee, In-Kyoung; Lee, Sang-Yeop

    2016-01-01

    The culture filtrate of Lentinula edodes shows potent antimicrobial activity against the plant pathogenic bacteria Ralstonia solanacearum. Bioassay-guided fractionation was conducted using Diaion HP-20 column chromatography, and the insoluble active compound was not adsorbed on the resin. Further fractionation by high-performance liquid chromatography (HPLC) suggested that the active compounds were organic acids. Nine organic acids were detected in the culture filtrate of L. edodes; oxalic acid was the major component and exhibited antibacterial activity against nine different phytopathogenic bacteria. Quantitative analysis by HPLC revealed that the content of oxalic acid was higher in the water extract from spent mushroom substrate than in liquid culture. This suggests that the water extract of spent L. edodes substrate is an eco-friendly control agent for plant diseases. PMID:28154495

  8. An evaluation of three processing methods and the effect of reduced culture times for faster direct identification of pathogens from BacT/ALERT blood cultures by MALDI-TOF MS.

    PubMed

    Loonen, A J M; Jansz, A R; Stalpers, J; Wolffs, P F G; van den Brule, A J C

    2012-07-01

    Matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF MS) is a fast and reliable method for the identification of bacteria from agar media. Direct identification from positive blood cultures should decrease the time to obtaining the result. In this study, three different processing methods for the rapid direct identification of bacteria from positive blood culture bottles were compared. In total, 101 positive aerobe BacT/ALERT bottles were included in this study. Aliquots from all bottles were used for three bacterial processing methods, i.e. the commercially available Bruker's MALDI Sepsityper kit, the commercially available Molzym's MolYsis Basic5 kit and a centrifugation/washing method. In addition, the best method was used to evaluate the possibility of MALDI application after a reduced incubation time of 7 h of Staphylococcus aureus- and Escherichia coli-spiked (1,000, 100 and 10 colony-forming units [CFU]) aerobe BacT/ALERT blood cultures. Sixty-six (65%), 51 (50.5%) and 79 (78%) bottles were identified correctly at the species level when the centrifugation/washing method, MolYsis Basic 5 and Sepsityper were used, respectively. Incorrect identification was obtained in 35 (35%), 50 (49.5%) and 22 (22%) bottles, respectively. Gram-positive cocci were correctly identified in 33/52 (64%) of the cases. However, Gram-negative rods showed a correct identification in 45/47 (96%) of all bottles when the Sepsityper kit was used. Seven hours of pre-incubation of S. aureus- and E. coli-spiked aerobe BacT/ALERT blood cultures never resulted in reliable identification with MALDI-TOF MS. Sepsityper is superior for the direct identification of microorganisms from aerobe BacT/ALERT bottles. Gram-negative pathogens show better results compared to Gram-positive bacteria. Reduced incubation followed by MALDI-TOF MS did not result in faster reliable identification.

  9. The Quantitative Measurement of Organizational Culture in Health Care: A Review of the Available Instruments

    PubMed Central

    Scott, Tim; Mannion, Russell; Davies, Huw; Marshall, Martin

    2003-01-01

    Objective To review the quantitative instruments available to health service researchers who want to measure culture and cultural change. Data Sources A literature search was conducted using Medline, Cinahl, Helmis, Psychlit, Dhdata, and the database of the King's Fund in London for articles published up to June 2001, using the phrase “organizational culture.” In addition, all citations and the gray literature were reviewed and advice was sought from experts in the field to identify instruments not found on the electronic databases. The search focused on instruments used to quantify culture with a track record, or potential for use, in health care settings. Data Extraction For each instrument we examined the cultural dimensions addressed, the number of items for each questionnaire, the measurement scale adopted, examples of studies that had used the tool, the scientific properties of the instrument, and its strengths and limitations. Principal Findings Thirteen instruments were found that satisfied our inclusion criteria, of which nine have a track record in studies involving health care organizations. The instruments varied considerably in terms of their grounding in theory, format, length, scope, and scientific properties. Conclusions A range of instruments with differing characteristics are available to researchers interested in organizational culture, all of which have limitations in terms of their scope, ease of use, or scientific properties. The choice of instrument should be determined by how organizational culture is conceptualized by the research team, the purpose of the investigation, intended use of the results, and availability of resources. PMID:12822919

  10. Quantitative Assessment of Foot Blood Flow by Using Dynamic Volume Perfusion CT Technique: A Feasibility Study.

    PubMed

    Hur, Saebeom; Jae, Hwan Jun; Jang, Yeonggul; Min, Seung-Kee; Min, Sang-Il; Lee, Dong Yeon; Seo, Sang Gyo; Kim, Hyo-Cheol; Chung, Jin Wook; Kim, Kwang Gi; Park, Eun-Ah; Lee, Whal

    2016-04-01

    To demonstrate the feasibility of foot blood flow measurement by using dynamic volume perfusion computed tomographic (CT) technique with the upslope method in an animal experiment and a human study. The human study was approved by the institutional review board, and written informed consent was obtained from all patients. The animal study was approved by the research animal care and use committee. A perfusion CT experiment was first performed by using rabbits. A color-coded perfusion map was reconstructed by using in-house perfusion analysis software based on the upslope method, and the measured blood flow on the map was compared with the reference standard microsphere method by using correlation analysis. A total of 17 perfusion CT sessions were then performed (a) once in five human patients and (b) twice (before and after endovascular revascularization) in six human patients. Perfusion maps of blood flow were reconstructed and analyzed. The Wilcoxon signed rank test was used to prove significant differences in blood flow before and after treatment. The animal experiment demonstrated a strong correlation (R(2) = 0.965) in blood flow between perfusion CT and the microsphere method. Perfusion maps were obtained successfully in 16 human clinical sessions (94%) with the use of 32 mL of contrast medium and an effective radiation dose of 0.31 mSv (k factor for the ankle, 0.0002). The plantar dermis showed the highest blood flow among all anatomic structures of the foot, including muscle, subcutaneous tissue, tendon, and bone. After a successful revascularization procedure, the blood flow of the plantar dermis increased by 153% (P = .031). The interpretations of the color-coded perfusion map correlated well with the clinical and angiographic findings. Perfusion CT could be used to measure foot blood flow in both animals and humans. It can be a useful modality for the diagnosis of peripheral arterial disease by providing quantitative information on foot perfusion status.

  11. Cord blood testing

    MedlinePlus

    ... Blood culture (if an infection is suspected) Blood gases (including oxygen, carbon dioxide, and pH levels) Blood ... 2018, A.D.A.M., Inc. Duplication for commercial use must be authorized in writing by ADAM ...

  12. A selective and sensitive method for quantitation of lysergic acid diethylamide (LSD) in whole blood by gas chromatography-ion trap tandem mass spectrometry.

    PubMed

    Libong, Danielle; Bouchonnet, Stéphane; Ricordel, Ivan

    2003-01-01

    A gas chromatography-ion trap tandem mass spectrometry (GC-ion trap MS-MS) method for detection and quantitation of LSD in whole blood is presented. The sample preparation process, including a solid-phase extraction step with Bond Elut cartridges, was performed with 2 mL of whole blood. Eight microliters of the purified extract was injected with a cold on-column injection method. Positive chemical ionization was performed using acetonitrile as reagent gas; LSD was detected in the MS-MS mode. The chromatograms obtained from blood extracts showed the great selectivity of the method. GC-MS quantitation was performed using lysergic acid methylpropylamide as the internal standard. The response of the MS was linear for concentrations ranging from 0.02 ng/mL (detection threshold) to 10.0 ng/mL. Several parameters such as the choice of the capillary column, the choice of the internal standard and that of the ionization mode (positive CI vs. EI) were rationalized. Decomposition pathways under both ionization modes were studied. Within-day and between-day stability were evaluated.

  13. In the era of the 24 h laboratory, does communicating Gram stain results from blood cultures flagging positive outside of conventional working hours alter patient management?

    PubMed

    Moore, Jonathan S; Koerner, Roland J

    2015-11-01

    As laboratories move towards 24 h a day working patterns, we aim to evaluate if expediting the availability of provisional blood culture results outside of normal working hours would derive clinical benefit. 116 blood cultures flagging positive outside of conventional working hours (20:00-09:00) were studied. In each case, medical records were reviewed and cases discussed with clinicians to determine if earlier communication of results would have altered management and affected the outcome. Organisms were seen in 102/116 blood cultures. In total, 76/82 (92.7%) patients with cultures deemed to be significant were on an antibiotic. The isolate was sensitive to the prescribed antibiotic in 56/74 (76%) cases. Input from a microbiologist is likely to have altered management in 14 (13.7%) cases, but unlikely to have affected any outcomes. We found no compelling evidence that expediting the availability of Gram stain results from positive blood cultures alone improves patient outcome. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  14. Use of Positive Blood Cultures for Direct Identification and Susceptibility Testing with the Vitek 2 System

    PubMed Central

    de Cueto, Marina; Ceballos, Esther; Martinez-Martinez, Luis; Perea, Evelio J.; Pascual, Alvaro

    2004-01-01

    In order to further decrease the time lapse between initial inoculation of blood culture media and the reporting of results of identification and antimicrobial susceptibility tests for microorganisms causing bacteremia, we performed a prospective study in which specially processed fluid from positive blood culture bottles from Bactec 9240 (Becton Dickinson, Cockeysville, Md.) containing aerobic media were directly inoculated into Vitek 2 system cards (bio-Mérieux, France). Organism identification and susceptibility results were compared with those obtained from cards inoculated with a standardized bacterial suspension obtained following subculture to agar; 100 consecutive positive monomicrobic blood cultures, consisting of 50 gram-negative rods and 50 gram-positive cocci, were included in the study. For gram-negative organisms, 31 of the 50 (62%) showed complete agreement with the standard method for species identification, while none of the 50 gram-positive cocci were correctly identified by the direct method. For gram-negative rods, there were 50% categorical agreements between the direct and standard methods for all drugs tested. The very major error rate was 2.4%, and the major error rate was 0.6%. The overall error rate for gram-negatives was 6.6%. Complete agreement in clinical categories of all antimicrobial agents evaluated was obtained for 19 of 50 (38%) gram-positive cocci evaluated; the overall error rate was 8.4%, with 2.8% minor errors, 2.4% major errors, and 3.2% very major errors. These findings suggest that the Vitek 2 cards inoculated directly from positive Bactec 9240 bottles do not provide acceptable bacterial identification or susceptibility testing in comparison with corresponding cards tested by a standard method. PMID:15297523

  15. Integrated quantitative phase and birefringence microscopy for imaging malaria-infected red blood cells.

    PubMed

    Li, Chengshuai; Chen, Shichao; Klemba, Michael; Zhu, Yizheng

    2016-09-01

    A dual-modality birefringence/phase imaging system is presented. The system features a crystal retarder that provides polarization mixing and generates two interferometric carrier waves in a single signal spectrum. The retardation and orientation of sample birefringence can then be measured simultaneously based on spectral multiplexing interferometry. Further, with the addition of a Nomarski prism, the same setup can be used for quantitative differential interference contrast (DIC) imaging. Sample phase can then be obtained with two-dimensional integration. In addition, birefringence-induced phase error can be corrected using the birefringence data. This dual-modality approach is analyzed theoretically with Jones calculus and validated experimentally with malaria-infected red blood cells. The system generates not only corrected DIC and phase images, but a birefringence map that highlights the distribution of hemozoin crystals.

  16. Integrated quantitative phase and birefringence microscopy for imaging malaria-infected red blood cells

    NASA Astrophysics Data System (ADS)

    Li, Chengshuai; Chen, Shichao; Klemba, Michael; Zhu, Yizheng

    2016-09-01

    A dual-modality birefringence/phase imaging system is presented. The system features a crystal retarder that provides polarization mixing and generates two interferometric carrier waves in a single signal spectrum. The retardation and orientation of sample birefringence can then be measured simultaneously based on spectral multiplexing interferometry. Further, with the addition of a Nomarski prism, the same setup can be used for quantitative differential interference contrast (DIC) imaging. Sample phase can then be obtained with two-dimensional integration. In addition, birefringence-induced phase error can be corrected using the birefringence data. This dual-modality approach is analyzed theoretically with Jones calculus and validated experimentally with malaria-infected red blood cells. The system generates not only corrected DIC and phase images, but a birefringence map that highlights the distribution of hemozoin crystals.

  17. Impact of invasive and noninvasive quantitative culture sampling on outcome of ventilator-associated pneumonia: a pilot study.

    PubMed

    Sanchez-Nieto, J M; Torres, A; Garcia-Cordoba, F; El-Ebiary, M; Carrillo, A; Ruiz, J; Nuñez, M L; Niederman, M

    1998-02-01

    We performed an open, prospective, randomized clinical trial in 51 patients receiving mechanical ventilation for more than 72 h, in order to evaluate the impact of using either invasive (protected specimen brush [PSB] and bronchoalveolar lavage [BAL] via fiberoptic bronchoscopy) or noninvasive (quantitative endotracheal aspirates [QEA]) diagnostic methods on the morbidity and mortality of ventilator-associated pneumonia (VAP). Patients were randomly assigned to two groups: Group A patients (n = 24) underwent QEA, PSB, and BAL; Group B patients (n = 27) underwent only QEA cultures. Empiric antibiotic treatment was given according to the attending physician and was modified according to the results of cultures and sensitivity in Group A using PSB and BAL results and in Group B based upon QEA cultures. Bacteriologic cultures were done quantitatively for EA, PSB, and BAL. Thresholds of > or = 10(5), > or = 10(3), and > or = 10(4) CFU/ml were used for QEA, PSB, and BAL, respectively. Microbial cultures from Group A patients were positive in 16 (67%) BAL samples, 14 (58%) PSB samples, and 16 (67%) QEA samples. In Group B patients, QEA microbial cultures yielded positive results in 20 of 27 (74%) samples. In Group A, there was total agreement between culture results of the three techniques on 17 (71%) occasions. In five (21%) cases, QEA coincided with either BAL or PBS. In only two (8%) cases, QEA cultures did not coincide with either PSB or BAL. No cases of positive BAL or PSB cultures had negative QEA cultures. Initial antibiotic treatment was modified in 10 (42%) patients from Group A and in four (16%) patients from Group B (p < 0.05). The observed crude mortality rate was 11 of 24 (46%) in Group A, and 7 of 27 (26%) in Group B, whereas the adjusted mortality rates (observed crude minus predicted at admission) for Groups A and B were 29 and 10%, respectively. There were no statistically significant differences when comparing crude and adjusted mortality rates of Groups

  18. Quantitative determination of steroids in the fruiting bodies and submerged-cultured mycelia of Inonotus obliquus.

    PubMed

    Gao, Yuan; Xu, Hongyu; Lu, Zhenming; Xu, Zhenghong

    2009-11-01

    This study describes the method of quantitative determination of betulin, ergosterol, cholesterol, lanosterol, stigmasterol and sitosterol in the fruiting bodies and submerged-cultured mycelia of Inonotus obliquus. A high performance liquid chromatographic (HPLC) method was applied to separate these steroids. The procedure was carried out on a reversed-phase C, column, using a stepwise gradient of water-methanol as mobile phase with the following profile: 0-10 min, 10% water, 90% methanol; 10-40 min, 3% water, 97% methanol. The flow rate was 1.4 mL/min and the detection wavelength was 202 nm. The analysis was completed within 40 min. The results showed that this method has good reproducibility and satisfactory recoveries for the determination of steroids. The relative standard deviations of the peak areas were less than 2.94% (n = 5) for intraday assays. A good linear correlation was obtained in a range of 0.4-4.8 microg. The recoveries of betulin, ergosterol, cholesterol, lanosterol, stigmasterol, and sitosterol were 100.05%-100.72%, 99.31%-101.04%, 97.52%-101.63%, 96.61%-100.08%, 96.21%-100.76% and 100.04%-100.51%, respectively. This method can be applied to evaluate real samples, and it is rapid, accurate and suitable for the quantitative determination of steroids in the fruiting bodies and submerged-cultured mycelia of Inonotus obliquus.

  19. Cytokine Production in Mixed Cultures of Mesenchymal Stromal Cells from Wharton's Jelly and Peripheral Blood Lymphocytes.

    PubMed

    Poltavtsev, A M; Poltavtseva, R A; Yushina, M N; Volgina, N E; Svirshchevskaya, E V

    2017-05-01

    We compared the production of 19 humoral factors in mixed cultures of mesenchymal stromal cells from Wharton's jelly and allogenic peripheral blood lymphocytes. For evaluation of the specificity of immunosuppressive activity of mesenchymal stromal cells, comparative analysis of the production of these humoral factors in mixed cultures of lymphocytes and epithelial BxPC-3 cells was conducted. The production of soluble factors in both mono- and mixed cultures significantly correlated (p<0.05). The maximum production was found for proinflammatory chemokine IP-10 and IFN-γ and anti-inflammatory cytokine IL-10. The major difference of mesenchymal stromal cells from epithelial BxPC-3 cells was 7-fold higher production of IL-10, which can explain the immunosuppressive effect of mesenchymal stromal cells.

  20. Volume dependency for culture of fungi from respiratory secretions and increased sensitivity of Aspergillus quantitative PCR.

    PubMed

    Fraczek, Marcin G; Kirwan, Marie B; Moore, Caroline B; Morris, Julie; Denning, David W; Richardson, Malcolm D

    2014-02-01

    Diagnosis of aspergillosis is often difficult. We compared fungal yields from respiratory specimens using the Health Protection Agency standard culture method (BSOP57), a higher volume undiluted culture method Mycology Reference Centre Manchester (MRCM) and Aspergillus quantitative real time polymerase chain reaction (qPCR). Sputum, bronchial aspirate and bronchoalveolar lavage (BAL) samples (total 23) were collected from aspergillosis patients. One fraction of all samples was cultured using the MRCM method, one BSOP57 and one was used for qPCR. The recovery rate for fungi was significantly higher by MRCM (87%) than by BSOP57 (8.7%) from all 23 specimens. Sputum samples were 44% positive by MRCM compared to no fungi isolated (0%) by BSOP57. Bronchial aspirates were 75% positive by MRCM and 0% by BSOP57. BAL samples were positive in 20% by MRCM and 10% by BSOP57. qPCR was always more sensitive than culture (95.6%) from all samples. In general, over 100 mould colonies (81 Aspergillus fumigatus) were grown using the MRCM method compared with only one colony from BSOP57. This study provides a reference point for standardisation of respiratory sample processing in diagnostic laboratories. Culture from higher volume undiluted respiratory specimens has a much higher yield for Aspergillus than BSOP57. qPCR is much more sensitive than culture and the current UK method requires revision. © 2013 Blackwell Verlag GmbH.

  1. Cerebral Metabolic Rate of Oxygen (CMRO2 ) Mapping by Combining Quantitative Susceptibility Mapping (QSM) and Quantitative Blood Oxygenation Level-Dependent Imaging (qBOLD).

    PubMed

    Cho, Junghun; Kee, Youngwook; Spincemaille, Pascal; Nguyen, Thanh D; Zhang, Jingwei; Gupta, Ajay; Zhang, Shun; Wang, Yi

    2018-03-07

    To map the cerebral metabolic rate of oxygen (CMRO 2 ) by estimating the oxygen extraction fraction (OEF) from gradient echo imaging (GRE) using phase and magnitude of the GRE data. 3D multi-echo gradient echo imaging and perfusion imaging with arterial spin labeling were performed in 11 healthy subjects. CMRO 2 and OEF maps were reconstructed by joint quantitative susceptibility mapping (QSM) to process GRE phases and quantitative blood oxygen level-dependent (qBOLD) modeling to process GRE magnitudes. Comparisons with QSM and qBOLD alone were performed using ROI analysis, paired t-tests, and Bland-Altman plot. The average CMRO 2 value in cortical gray matter across subjects were 140.4 ± 14.9, 134.1 ± 12.5, and 184.6 ± 17.9 μmol/100 g/min, with corresponding OEFs of 30.9 ± 3.4%, 30.0 ± 1.8%, and 40.9 ± 2.4% for methods based on QSM, qBOLD, and QSM+qBOLD, respectively. QSM+qBOLD provided the highest CMRO 2 contrast between gray and white matter, more uniform OEF than QSM, and less noisy OEF than qBOLD. Quantitative CMRO 2 mapping that fits the entire complex GRE data is feasible by combining QSM analysis of phase and qBOLD analysis of magnitude. © 2018 International Society for Magnetic Resonance in Medicine.

  2. Using digital inline holographic microscopy and quantitative phase contrast imaging to assess viability of cultured mammalian cells

    NASA Astrophysics Data System (ADS)

    Missan, Sergey; Hrytsenko, Olga

    2015-03-01

    Digital inline holographic microscopy was used to record holograms of mammalian cells (HEK293, B16, and E0771) in culture. The holograms have been reconstructed using Octopus software (4Deep inwater imaging) and phase shift maps were unwrapped using the FFT-based phase unwrapping algorithm. The unwrapped phase shifts were used to determine the maximum phase shifts in individual cells. Addition of 0.5 mM H2O2 to cell media produced rapid rounding of cultured cells, followed by cell membrane rupture. The cell morphology changes and cell membrane ruptures were detected in real time and were apparent in the unwrapped phase shift images. The results indicate that quantitative phase contrast imaging produced by the digital inline holographic microscope can be used for the label-free real time automated determination of cell viability and confluence in mammalian cell cultures.

  3. Evaluation of a Semiquantitative Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Method for Rapid Antimicrobial Susceptibility Testing of Positive Blood Cultures.

    PubMed

    Jung, Jette S; Hamacher, Christina; Gross, Birgit; Sparbier, Katrin; Lange, Christoph; Kostrzewa, Markus; Schubert, Sören

    2016-11-01

    With the increasing prevalence of multidrug-resistant Gram-negative bacteria, rapid identification of the pathogen and its individual antibiotic resistance is crucial to ensure adequate antiinfective treatment at the earliest time point. Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry for the identification of bacteria directly from the blood culture bottle has been widely established; however, there is still an urgent need for new methods that permit rapid resistance testing. Recently, a semiquantitative MALDI-TOF mass spectrometry-based method for the prediction of antibiotic resistance was described. We evaluated this method for detecting nonsusceptibility against two β-lactam and two non-β-lactam antibiotics. A collection of 30 spiked blood cultures was tested for nonsusceptibility against gentamicin and ciprofloxacin. Furthermore, 99 patient-derived blood cultures were tested for nonsusceptibility against cefotaxime, piperacillin-tazobactam, and ciprofloxacin in parallel with MALDI-TOF mass spectrometry identification from the blood culture fluid. The assay correctly classified all isolates tested for nonsusceptibility against gentamicin and cefotaxime. One misclassification for ciprofloxacin nonsusceptibility and five misclassifications for piperacillin-tazobactam nonsusceptibility occurred. Identification of the bacterium and prediction of nonsusceptibility was possible within approximately 4 h. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  4. Flow microfluorometric analysis of phagocyte degranulation in bacteria-infected whole human blood cell cultures

    NASA Astrophysics Data System (ADS)

    Kravtsov, Alexander L.; Bobyleva, Elena V.; Grebenyukova, Tatyana P.; Kuznetsov, Oleg S.; Kulyash, Youri V.

    2002-07-01

    A quantitative flow microfluorometric method was used to study the intensity of human blood phagocyte degranulation in response to viable staphylococcus aureus or Yersinia pestis cells. Microorganisms were added directly to defibrinated whole blood. Uninfected and infected blood samples were incubated at 37 degrees C to 8 h. The results were recorded in dynamics after the staining of whole blood with acridine orange solution. Lymphocytes with a low azurophilic granule per cell content were discriminated from phagocytes by the measurement of single cell red cytoplasmic granule fluorescence. 30,000 cells in each sample were examined. S. aureus cells caused a dose-dependent decrease in the number of phagocytes having a high red cytoplasmic fluorescence intensity and a corresponding increase in the weakly fluorescence cell population. In the presence of an initial S. aureus-to-phagocyte ratio more than 1:1, degranulation was measured after 3 h of incubation and to 8 h the percentage of degranulated phagocytes was at least 100 percent Y. pestis cells grown for 48 h at 28 degrees C caused at same condition as the degranulation only about 50 percent of cells. Y.pestis EV cells preincubated in broth for 12 h at 37 degrees C did no stimulate the phahocyte degranulation. The results of these studies suggest that analysis of cell populations via flow microfluorimeter technology may be a powerful tool in analysis bacterial infection.

  5. Rapid identification of pneumococci, enterococci, beta-haemolytic streptococci and S. aureus from positive blood cultures enabling early reports.

    PubMed

    Larsson, Marie C; Karlsson, Ewa; Woksepp, Hanna; Frölander, Kerstin; Mårtensson, Agneta; Rashed, Foad; Annika, Wistedt; Schön, Thomas; Serrander, Lena

    2014-03-19

    The aim of this study was to evaluate diagnostic tests in order to introduce a diagnostic strategy to identify the most common gram-positive bacteria (pneumococci, enterococci, β-haemolytic streptococci and S. aureus) found in blood cultures within 6 hours after signalling growth. The tube coagulase test was optimized and several latex agglutination tests were compared and evaluated before a validation period of 11 months was performed on consecutive positive blood culture patient samples from Kalmar County Hospital, Sweden. During the validation period 150 (91%) of a total of 166 gram-positive cocci (119 in clusters, 45 in chains or pairs and 2 undefined morphology) were correctly identified as S. aureus, CoNS, Pneumococci, Enterococci or group A streptococci (GAS), group B streptococci (GBS), group G streptococci (GGS) within 6 hours with a minimal increase in work-load and costs. The remaining samples (9%) were correctly identified during the next day. No samples were incorrectly grouped with this diagnostic strategy and no patient came to risk by early reporting. A simple strategy gives reliable and cost-effective reporting of >90% of the most common gram-positive cocci within 6 hours after a blood cultures become positive. The high specificity of the tests used makes preliminary reports reliable. The reports can be used to indicate the focus of infection and not the least, support faster administration of proper antimicrobial treatment for patients with serious bacterial infections.

  6. Syndrome Evaluation System (SES) versus Blood Culture (BACTEC) in the Diagnosis and Management of Neonatal Sepsis--A Randomized Controlled Trial.

    PubMed

    Bhat, B Vishnu; Prasad, P; Ravi Kumar, Venkata Banda; Harish, B N; Krishnakumari, K; Rekha, Anand; Manjunath, G; Adhisivam, B; Shruthi, B

    2016-05-01

    To compare the clinical outcome of a multiplex polymerase chain reaction (PCR) based molecular diagnostic method -- Syndrome Evaluation System (SES) directed treatment strategy vs. standard of care (blood culture) directed treatment strategy for neonatal sepsis. This randomized controlled trial (RCT) included 385 neonates with sepsis who were randomized into two groups -- SES and control (BACTEC). Both tests were performed for all the neonates. However, in the SES group, the results of SES test were revealed to the treating clinicians, while in the control group, SES results were withheld. Two ml of blood was drawn from each baby. One aliquot was sent for blood culture, whereas the remaining aliquot was sent for SES. Babies were then administered empirical IV antibiotics and given supportive care. Further antibiotic changes, if required were done in SES and control groups based on their respective reports. The microbiological profile, immediate outcome, duration of hospital stay, number of antibiotics used and readmission within a month in both groups were compared. SES was better than BACTEC in identifying the causative organism in both the groups (68 % vs. 18 % in SES group and 72 % vs. 18 % in control group). SES had 100 % concordance with blood culture by BACTEC. Detection of bacteria and fungi were four and ten-fold higher respectively with SES when compared to BACTEC culture. Microbiological diagnosis was rapid with SES compared to BACTEC (7 h vs. 72 h). Treatment based on SES resulted in significantly less mortality (3 % vs. 18 %). Readmission rate, duration of hospital stay and change in antibiotics were also significantly less in SES group. This new molecular based diagnostic system (SES) helps in rapid and accurate diagnosis of neonatal sepsis and reduces mortality and morbidity in affected neonates.

  7. Mesenchymal stem cells from the Wharton's jelly of umbilical cord segments provide stromal support for the maintenance of cord blood hematopoietic stem cells during long-term ex vivo culture.

    PubMed

    Bakhshi, Tiki; Zabriskie, Ryan C; Bodie, Shamanique; Kidd, Shannon; Ramin, Susan; Paganessi, Laura A; Gregory, Stephanie A; Fung, Henry C; Christopherson, Kent W

    2008-12-01

    Hematopoietic stem cells (HSCs) are routinely obtained from marrow, mobilized peripheral blood, and umbilical cord blood. Mesenchymal stem cells (MSCs) are traditionally isolated from marrow. Bone marrow-derived MSCs (BM-MSCs) have previously demonstrated their ability to act as a feeder layer in support of ex vivo cord blood expansion. However, the use of BM-MSCs to support the growth, differentiation, and engraftment of cord blood may not be ideal for transplant purposes. Therefore, the potential of MSCs from a novel source, the Wharton's jelly of umbilical cords, to act as stromal support for the long-term culture of cord blood HSC was evaluated. Umbilical cord-derived MSCs (UC-MSCs) were cultured from the Wharton's jelly of umbilical cord segments. The UC-MSCs were then profiled for expression of 12 cell surface receptors and tested for their ability to support cord blood HSCs in a long-term culture-initiating cell (LTC-IC) assay. Upon culture, UC-MSCs express a defined set of cell surface markers (CD29, CD44, CD73, CD90, CD105, CD166, and HLA-A) and lack other markers (CD45, CD34, CD38, CD117, and HLA-DR) similar to BM-MSCs. Like BM-MSCs, UC-MSCs effectively support the growth of CD34+ cord blood cells in LTC-IC assays. These data suggest the potential therapeutic application of Wharton's jelly-derived UC-MSCs to provide stromal support structure for the long-term culture of cord blood HSCs as well as the possibility of cotransplantation of genetically identical, HLA-matched, or unmatched cord blood HSCs and UC-MSCs in the setting of HSC transplantation.

  8. Semi-quantitative MALDI-TOF for antimicrobial susceptibility testing in Staphylococcus aureus.

    PubMed

    Maxson, Tucker; Taylor-Howell, Cheryl L; Minogue, Timothy D

    2017-01-01

    Antibiotic resistant bacterial infections are a significant problem in the healthcare setting, in many cases requiring the rapid administration of appropriate and effective antibiotic therapy. Diagnostic assays capable of quickly and accurately determining the pathogen resistance profile are therefore crucial to initiate or modify care. Matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) is a standard method for species identification in many clinical microbiology laboratories and is well positioned to be applied towards antimicrobial susceptibility testing. One recently reported approach utilizes semi-quantitative MALDI-TOF MS for growth rate analysis to provide a resistance profile independent of resistance mechanism. This method was previously successfully applied to Gram-negative pathogens and mycobacteria; here, we evaluated this method with the Gram-positive pathogen Staphylococcus aureus. Specifically, we used 35 strains of S. aureus and four antibiotics to optimize and test the assay, resulting in an overall accuracy rate of 95%. Application of the optimized assay also successfully determined susceptibility from mock blood cultures, allowing both species identification and resistance determination for all four antibiotics within 3 hours of blood culture positivity.

  9. In vitro cartilage construct generation from silk fibroin- chitosan porous scaffold and umbilical cord blood derived human mesenchymal stem cells in dynamic culture condition.

    PubMed

    Agrawal, Parinita; Pramanik, Krishna; Biswas, Amit; Ku Patra, Ranjan

    2018-02-01

    Cartilage construct generation includes a scaffold with appropriate composition to mimic matrix of the damaged tissue on which the stem cells grow and differentiate. In this study, umbilical cord blood (UCB) derived human mesenchymal stem cells (hMSCs) were seeded on freeze dried porous silk-fibroin (SF)/chitosan (CS) scaffolds. Influence of static and dynamic (spinner flask bioreactor) culture conditions on the developing cartilage construct were studied by in-vitro characterization for viability, proliferation, distribution, and chondrogenic differentiation of hMSCs over the scaffold. Constructs developed in spinner flask consisted of 62% live cells, and exhibited 543% more cell density at the core than constructs cultured in static system. Quantification of DNA and glycosaminoglycans accumulation after 21 days showed the progression of chondrogenic differentiation of hMSCs was higher in dynamic culture compared to static one. In constructs generated under dynamic condition, histology staining for proteoglycan matrix, and fluorescence staining for collagen-II and aggrecan showed positive correlation between early and late stage chondrogenic markers, which was further confirmed by quantitative PCR analysis, showing low collagen-I expression and highly expressed Sox9, collagen-II and aggrecan. The present study demonstrated that construct generated by combining 3D SF/CS scaffold with UCB-hMSCs under dynamic condition using spinner flask bioreactor can be used for cartilage tissue regeneration for future medical treatments. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 397-407, 2018. © 2017 Wiley Periodicals, Inc.

  10. The Bactec FX Blood Culture System Detects Brucella melitensis Bacteremia in Adult Patients within the Routine 1-Week Incubation Period.

    PubMed

    Sagi, Moshe; Nesher, Lior; Yagupsky, Pablo

    2017-03-01

    The performance of the Bactec FX blood culture system for detecting Brucella bacteremia within the routine 1-week incubation period was assessed in a prospective study conducted in an area in southern Israel in which Brucella melitensis is endemic. Aerobic vials (BD Bactec Plus Aerobic/F medium) inoculated with blood specimens obtained from adult patients with positive Rose-Bengal screening test results were monitored for 4 consecutive weeks, and blind subcultures of negative vials were performed on solid media on days 7 and 28. During a 16-month period, a total of 31 (35.2%) of 88 cultures, obtained from 19 (38.0%) of 50 patients, were positive for Brucella melitensis The blood culture instrument identified 30 (96.8%) of 31 positive vials within 7 days of incubation; the single positive vial that was missed by the automated readings was detected only by the blind subculture performed on day 28. It is concluded that the Bactec FX system is able to detect the vast majority of episodes of Brucella bacteremia within the 1-week incubation protocol instituted in most clinical microbiology laboratories and without the need to perform blind subcultures of negative vials, enabling early diagnosis and saving labor and incubation time and space. Copyright © 2017 American Society for Microbiology.

  11. The Influence of Acute Handling Stress on Some Blood Parameters in Cultured Sea Bream (Sparus Aurata Linnaeus, 1758)

    PubMed Central

    Fazio, Francesco; Ferrantelli, Vincenzo; Fortino, Gianluca; Giangrosso, Giuseppe; Faggio, Caterina

    2015-01-01

    The effect of acute handling stress on haematological profile, blood glucose and lactate (secondary stress markers) in cultured sea bream Sparus aurata was evaluated. Sixty six Sparus aurata were used and equally divided into two groups (A and B). Group A was not subjected to stress, Group B was subjected to acute handling stress. From each fish, biometric data and blood samples were collected to evaluate haematological profile, blood glucose and lactate. Unpaired t-test Student was applied to evaluate possible differences in parameters between the two groups. Red blood cells, haematocrit, haemoglobin, white blood cells (WBC), glucose and lactate showed an increase (P<0.05) in Group B compared with Group A, while mean corpuscular volume decreased (P<0.05) in Group B. The results highlight the role of studied parameters in monitoring the stressful conditions of aquaculture production which affect animal welfare and fish products quality. PMID:27800375

  12. Identification and Susceptibility Testing of Enterobacteriaceae and Pseudomonas aeruginosa by Direct Inoculation from Positive BACTEC Blood Culture Bottles into Vitek 2

    PubMed Central

    Bruins, Marjan J.; Bloembergen, Peter; Ruijs, Gijs J. H. M.; Wolfhagen, Maurice J. H. M.

    2004-01-01

    Inoculation of an automated system for rapid identification (ID) and antimicrobial susceptibility testing (AST) directly from positive blood culture bottles will reduce the turnaround time of laboratory diagnosis of septicemic patients, which benefits clinical outcome and decreases patient costs. Direct test results, however, must always be confirmed by testing a pure overnight culture, which is the “gold standard.” We studied the accuracy of direct testing versus repeat testing in order to investigate the possibility of refraining from repeat testing. We also assessed the clinical risk of reporting results based on direct testing only. We inoculated Vitek 2 (bioMérieux) directly from 410 positive BACTEC 9240 (BD) blood culture bottles containing gram-negative rods and studied the ID and AST results. In a comparison of direct inoculation with the standard method, a total of 344 isolates of Enterobacteriaceae and Pseudomonas aeruginosa were tested, and 93.0% were correctly identified. Of the 39 (10.2%) samples that contained bacilli not identifiable by Vitek 2, only 1 gave a conclusive, correct result. The overall MIC agreement among 312 isolates was 99.2%, with 0.8% very major and 0.02% major error rates. Of only three (polymicrobial) samples, the direct susceptibility pattern would be reported to the clinician as too sensitive. Vitek 2 results obtained from direct inoculation of blood culture bottles containing gram-negative bacilli are safe enough for immediate reporting, provided that ID and AST are consistent. Repeat testing is not necessary, unless Gram stain or overnight subculture results raise doubt about the purity of the culture. PMID:14715724

  13. Antifungal Activity of Propolis Against Yeasts Isolated From Blood Culture: In Vitro Evaluation.

    PubMed

    Mutlu Sariguzel, Fatma; Berk, Elife; Koc, Ayes Nedret; Sav, Hafize; Demir, Gonca

    2016-09-01

    Due to the failure of available antifungal agents in the treatment of candidemia and the toxic activities of these drugs, a lot of researches are being conducted to develop new nontoxic and effective antifungal agents for optimal control of fungal pathogens. The aim of this study is to evaluate the in vitro antifungal activity of propolis against yeasts isolated from the blood cultures of intensive care unit patients. Seventy-six strains were included in this study. The in vitro antifungal activity of propolis, fluconazole (FLU), and itraconazole (ITR) was investigated by the microdilution broth methods (CLSI guidelines M27-A3 for yeast). The propolis sample was collected from Kayseri, Turkey. Of the 76 isolates, 33 were identified as Candida albicans while 37 were C. parapsilosis, three were C. tropicalis, and three were identified as C. glabrata. The geometric mean range for MIC (μg/ml) with regard to all isolates was 0.077 to 3 μg/ml for FLU and ITR, and 0.375 to 0.70 μg/ml for propolis. It was shown that propolis had significant antifungal activity against all Candida strains and the MIC range of propolis was determined as 0185 to 3 μg/ml. This study demonstrated that propolis had significant antifungal activity against yeasts isolated from blood culture compared with FLU and ITR. The propolis MIC in azole-resistant strains such as C. glabrata was found lower than the FLU MIC. © 2015 Wiley Periodicals, Inc.

  14. A Study of Mercury Methylation Genetics: Qualitative and Quantitative Analysis of hgcAB in Pure Culture

    NASA Astrophysics Data System (ADS)

    Christensen, G. A.; Wymore, A. M.; King, A. J.; Podar, M.; Hurt, R. A., Jr.; Santillan, E. F. U.; Gilmour, C. C.; Brandt, C. C.; Brown, S. D.; Palumbo, A. V.; Elias, D. A.

    2015-12-01

    Two proteins (HgcA and HgcB) have been determined to be essential for mercury (Hg)-methylation and either one alone is not sufficient for this process. Detection and quantification of these genes to determine at risk environments is critical. Universal degenerate polymerase chain reaction (PCR) primers spanning hgcAB were developed to ascertain organismal diversity and validate that both genes were present as an established prerequisite for Hg-methylation. To confirm this approach, an extensive set of pure cultures with published genomes (including methylators and non-methylators: 13 Deltaproteobacteria, 9 Firmicutes, and 10 methanogenic Archaea) were assayed with the newly designed universal hgcAB primer set. A single band within an agarose gel was observed for the majority of the cultures with known hgcAB and confirmed via Sanger sequencing. For environmental applications, once the potential for Hg-methylation is established from PCR amplification with the universal hgcAB primer set, quantification of clade-specific hgcAB gene abundance is desirable. We developed quantitative polymerase chain reaction (qPCR) degenerate primers targeting hgcA from each of the three dominate clades (Deltaproteobacteria, Firmicutes and methanogenic Archaea) known to be associated with anaerobic Hg-methylation. The qPCR primers amplify virtually all hgcA positive cultures overall and are specific for their designed clade. Finally, to ensure the procedure is robust and sensitive in complex environmental matrices, cells from all clades were mixed in different combinations and ratios to assess qPCR primer specificity. The development and validation of these high fidelity quantitative molecular tools now allows for rapid and accurate risk management assessment in any environment.

  15. NanoFlares for the detection, isolation, and culture of live tumor cells from human blood.

    PubMed

    Halo, Tiffany L; McMahon, Kaylin M; Angeloni, Nicholas L; Xu, Yilin; Wang, Wei; Chinen, Alyssa B; Malin, Dmitry; Strekalova, Elena; Cryns, Vincent L; Cheng, Chonghui; Mirkin, Chad A; Thaxton, C Shad

    2014-12-02

    Metastasis portends a poor prognosis for cancer patients. Primary tumor cells disseminate through the bloodstream before the appearance of detectable metastatic lesions. The analysis of cancer cells in blood—so-called circulating tumor cells (CTCs)—may provide unprecedented opportunities for metastatic risk assessment and investigation. NanoFlares are nanoconstructs that enable live-cell detection of intracellular mRNA. NanoFlares, when coupled with flow cytometry, can be used to fluorescently detect genetic markers of CTCs in the context of whole blood. They allow one to detect as few as 100 live cancer cells per mL of blood and subsequently culture those cells. This technique can also be used to detect CTCs in a murine model of metastatic breast cancer. As such, NanoFlares provide, to our knowledge, the first genetic-based approach for detecting, isolating, and characterizing live cancer cells from blood and may provide new opportunities for cancer diagnosis, prognosis, and personalized therapy.

  16. NanoFlares for the detection, isolation, and culture of live tumor cells from human blood

    PubMed Central

    Halo, Tiffany L.; McMahon, Kaylin M.; Angeloni, Nicholas L.; Xu, Yilin; Wang, Wei; Chinen, Alyssa B.; Malin, Dmitry; Strekalova, Elena; Cryns, Vincent L.; Cheng, Chonghui; Mirkin, Chad A.; Thaxton, C. Shad

    2014-01-01

    Metastasis portends a poor prognosis for cancer patients. Primary tumor cells disseminate through the bloodstream before the appearance of detectable metastatic lesions. The analysis of cancer cells in blood—so-called circulating tumor cells (CTCs)—may provide unprecedented opportunities for metastatic risk assessment and investigation. NanoFlares are nanoconstructs that enable live-cell detection of intracellular mRNA. NanoFlares, when coupled with flow cytometry, can be used to fluorescently detect genetic markers of CTCs in the context of whole blood. They allow one to detect as few as 100 live cancer cells per mL of blood and subsequently culture those cells. This technique can also be used to detect CTCs in a murine model of metastatic breast cancer. As such, NanoFlares provide, to our knowledge, the first genetic-based approach for detecting, isolating, and characterizing live cancer cells from blood and may provide new opportunities for cancer diagnosis, prognosis, and personalized therapy. PMID:25404304

  17. Development and Validation of a Mediterranean Oriented Culture-Specific Semi-Quantitative Food Frequency Questionnaire

    PubMed Central

    Athanasiadou, Elpiniki; Kyrkou, Charikleia; Fotiou, Maria; Tsakoumaki, Foteini; Dimitropoulou, Aristea; Polychroniadou, Eleni; Menexes, Georgios; Athanasiadis, Apostolos P.; Biliaderis, Costas G.; Michaelidou, Alexandra-Maria

    2016-01-01

    The objectives were to develop a Mediterranean oriented semi-quantitative food frequency questionnaire (FFQ) and evaluate its validity in measuring energy and nutrient intakes. For FFQ development, the main challenge was to merge food items and practices reflecting cultural Mediterranean preferences with other food choices ensuing from diet transition to more westernized dietary patterns. FFQ validity was evaluated by comparing nutrient intakes against the average of two 24-h dietary recalls for 179 pregnant women. Although the mean intake values for most nutrients and energy tended to be higher when determined by the FFQ, the Cohen’s d was below 0.3. Bland-Altman plots confirmed the agreement between the two methods. Positive significant correlations ranged from 0.35 to 0.77. The proportion of women classified correctly was between 73.2% and 92.2%, whereas gross misclassification was low. Weighted kappa values were between 0.31 and 0.78, while intraclass correlation coefficients were between 0.49 and 0.89. Our methodological approach for the development and validation of this FFQ provides reliable measurements of energy, macro- and micronutrient intakes. Overall, our culture-specific FFQ could serve as a useful assessment tool in studies aiming at monitoring dietary intakes, especially in the Mediterranean region, where countries share common cultural dietary habits. PMID:27571097

  18. Rapid identification of bacteria from positive blood culture bottles by use of matrix-assisted laser desorption-ionization time of flight mass spectrometry fingerprinting.

    PubMed

    Christner, Martin; Rohde, Holger; Wolters, Manuel; Sobottka, Ingo; Wegscheider, Karl; Aepfelbacher, Martin

    2010-05-01

    Early and adequate antimicrobial therapy has been shown to improve the clinical outcome in bloodstream infections (BSI). To provide rapid pathogen identification for targeted treatment, we applied matrix-assisted laser desorption-ionization time of flight (MALDI-TOF) mass spectrometry fingerprinting to bacteria directly recovered from blood culture bottles. A total of 304 aerobic and anaerobic blood cultures, reported positive by a Bactec 9240 system, were subjected in parallel to differential centrifugation with subsequent mass spectrometry fingerprinting and reference identification using established microbiological methods. A representative spectrum of bloodstream pathogens was recovered from 277 samples that grew a single bacterial isolate. Species identification by direct mass spectrometry fingerprinting matched reference identification in 95% of these samples and worked equally well for aerobic and anaerobic culture bottles. Application of commonly used score cutoffs to classify the fingerprinting results led to an identification rate of 87%. Mismatching mostly resulted from insufficient bacterial numbers and preferentially occurred with Gram-positive samples. The respective spectra showed low concordance to database references and were effectively rejected by score thresholds. Spiking experiments and examination of the respective study samples even suggested applicability of the method to mixed cultures. With turnaround times around 100 min, the approach allowed for reliable pathogen identification at the day of blood culture positivity, providing treatment-relevant information within the critical phase of septic illness.

  19. Improved Clinical Outcomes in Patients with Positive Blood Culture by Proactive Intervention of Antimicrobial Use-Impact of Antimicrobial Stewardship Program Implementation on Clinical Practice.

    PubMed

    Yamada, Takehiro; Kagami, Keisuke; Imai, Shungo; Akizawa, Koji; Iwasaki, Sumio; Fukumoto, Tatsuya; Ishiguro, Nobuhisa; Iseki, Ken

    2017-01-01

    Bacteremia is one of the most serious infectious illness resulting from nosocomial infection. Therefore, appropriate antimicrobial chemotherapy should be provided as soon as possible to patients exhibiting symptoms of infectious disease and having positive blood culture results. Antimicrobial stewardship (AS) guidelines were recently released by the Infectious Diseases Society of America. The guidelines recommend "proactive intervention and feedback" as one of the core strategies for implementing optimal antimicrobial drug use to improve patient outcomes in clinical settings. We began using the AS program for optimizing antimicrobial chemotherapy in patients with positive blood culture results. The results of blood cultures and antimicrobial prescriptions for the corresponding patients were daily reviewed by a pharmacist and a physician, members of the infection control team (ICT). If the antimicrobial agents selected were inappropriate, ICT made a recommendation to the attending physicians who prescribed the antibiotics. To evaluate the outcomes of this program, we conducted a single-center, retrospective investigation for near a hundred of patients who underwent intervention by infection-control physician and pharmacist. Resolution of bacteremia (determined by blood culture results) was 96.3% in the group that accepted intervention, whereas only 16.7% of the cases resolved in the group that did not accept intervention. These results strongly suggest the importance of the infection disease-specialist team intervention. This program could become an important method for improving clinical outcomes in patients with bacteremia.

  20. The Relevance of a Novel Quantitative Assay to Detect up to 40 Major Streptococcus pneumoniae Serotypes Directly in Clinical Nasopharyngeal and Blood Specimens

    PubMed Central

    Albrich, Werner C.; van der Linden, Mark P. G.; Bénet, Thomas; Chou, Monidarin; Sylla, Mariam; Barreto Costa, Patricia; Richard, Nathalie; Klugman, Keith P.; Endtz, Hubert P.; Paranhos-Baccalà, Gláucia; Telles, Jean-Noël

    2016-01-01

    For epidemiological and surveillance purposes, it is relevant to monitor the distribution and dynamics of Streptococcus pneumoniae serotypes. Conventional serotyping methods do not provide rapid or quantitative information on serotype loads. Quantitative serotyping may enable prediction of the invasiveness of a specific serotype compared to other serotypes carried. Here, we describe a novel, rapid multiplex real-time PCR assay for identification and quantification of the 40 most prevalent pneumococcal serotypes and the assay impacts in pneumonia specimens from emerging and developing countries. Eleven multiplex PCR to detect 40 serotypes or serogroups were optimized. Quantification was enabled by reference to standard dilutions of known bacterial load. Performance of the assay was evaluated to specifically type and quantify S. pneumoniae in nasopharyngeal and blood samples from adult and pediatric patients hospitalized with pneumonia (n = 664) from five different countries. Serogroup 6 was widely represented in nasopharyngeal specimens from all five cohorts. The most frequent serotypes in the French, South African, and Brazilian cohorts were 1 and 7A/F, 3 and 19F, and 14, respectively. When both samples were available, the serotype in blood was always present as carriage with other serotypes in the nasopharynx. Moreover, the ability of a serotype to invade the bloodstream may be linked to its nasopharyngeal load. The mean nasopharyngeal concentration of the serotypes that moved to the blood was 3 log-fold higher than the ones only found in the nasopharynx. This novel, rapid, quantitative assay may potentially predict some of the S. pneumoniae serotypes invasiveness and assessment of pneumococcal serotype distribution. PMID:26986831

  1. Sensitive Detection of Francisella tularensis Directly from Whole Blood by Use of the GeneXpert System.

    PubMed

    Banada, Padmapriya P; Deshpande, Srinidhi; Chakravorty, Soumitesh; Russo, Riccardo; Occi, James; Meister, Gabriel; Jones, Kelly J; Gelhaus, Carl H; Valderas, Michelle W; Jones, Martin; Connell, Nancy; Alland, David

    2017-01-01

    Francisella tularensis is a potential bioterrorism agent that is highly infectious at very low doses. Diagnosis of tularemia by blood culture and nucleic acid-based diagnostic tests is insufficiently sensitive. Here, we demonstrate a highly sensitive F. tularensis assay that incorporates sample processing and detection into a single cartridge suitable for point-of-care detection. The assay limit of detection (LOD) and dynamic range were determined in a filter-based cartridge run on the GeneXpert system. F. tularensis DNA in buffer or CFU of F. tularensis was spiked into human or macaque blood. To simulate detection in human disease, the assay was tested on blood drawn from macaques infected with F. tularensis Schu S4 at daily intervals. Assay detection was compared to that with a conventional quantitative PCR (qPCR) assay and blood culture. The assay LOD was 0.1 genome equivalents (GE) per reaction and 10 CFU/ml F. tularensis in both human and macaque blood. In infected macaques, the assay detected F. tularensis on days 1 to 4 postinfection in 21%, 17%, 60%, and 83% of macaques, respectively, compared to conventional qPCR positivity rates of 0%, 0%, 30%, and 100% and CFU detection of blood culture at 0%, 0%, 0%, and 10% positive, respectively. Assay specificity was 100%. The new cartridge-based assay can rapidly detect F. tularensis in bloodstream infections directly in whole blood at the early stages of infection with a sensitivity that is superior to that of other methods. The simplicity of the automated testing procedures may make this test suitable for rapid point-of-care detection. Copyright © 2016 American Society for Microbiology.

  2. Direct identification by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) from positive blood culture bottles: An opportunity to customize growth conditions for fastidious organisms causing bloodstream infections.

    PubMed

    Sharma, Megha; Gautam, Vikas; Mahajan, Monika; Rana, Sudesh; Majumdar, Manasi; Ray, Pallab

    2017-10-01

    Culture-negative bacteraemia has been an enigmatic entity with respect to its aetiological agents. In an attempt to actively identify those positive blood cultures that escape isolation and detection on routine workflow, an additional step of MALDI-TOF MS (matrix-assisted laser desorption ionization-time of flight mass spectrometry) based detection was carried out directly from the flagged blood culture bottles. Blood samples from 200 blood culture bottles that beeped positive with automated (BACTEC) system and showed no growth of organism on routine culture media, were subjected to analysis by MALDI-TOF MS. Forty seven of the 200 (23.5%) bacterial aetiology could be established by bottle-based method. Based on these results, growth on culture medium could be achieved for the isolates by providing special growth conditions to the fastidious organisms. Direct identification by MALDI-TOF MS from BACTEC-positive bottles provided an opportunity to isolate those fastidious organisms that failed to grow on routine culture medium by providing them with necessary alterations in growth environment.

  3. Evaluation of Antigen-Specific IgM and IgG Production during an In Vitro Peripheral Blood Mononuclear Cell Culture Assay.

    PubMed

    Matsuda, Yoshiko; Imamura, Ryoichi; Takahara, Shiro

    2017-01-01

    The recent attention given to diseases associated with memory B-cell (mBC)-produced antibodies (Abs) suggests the need for a similar in vitro assay to evaluate the functions of mBCs. Here, we cultured peripheral blood mononuclear cells (PBMCs) with the intent to collect mBC-derived Abs in vitro and maintain their cell-cell contact-dependent interactions with helper T-cells. PBMCs were cultured with interleukin (IL)-21, CpG-oligodeoxynucleotides (ODN), phorbol myristate acetate (PMA), and phytohemagglutinin/leucoagglutinin (PHA-L) in 24-well flat-bottom plates (5 × 10 5  cells/well). A culture supernatant analysis of PBMCs from healthy donors ( n  = 10) indicated that antigen-specific IgM Ab levels in a PBMC culture supernatant might be better able to demonstrate the antigen sensitization status in a smaller peripheral blood sample, compared to IgG because Epstein-Barr virus-specific IgM mBCs circulate peripherally at a significantly higher frequency once antiviral humoral immunity has stabilized. Thus, our in vitro assay demonstrated the potential significance of antigen-specific IgM Ab production in the culture supernatants. Furthermore, an analysis of cultured PBMCs from allograft kidney recipients ( n  = 16) sensitized with de novo donor-specific human leukocyte antigen (HLA)-specific Abs (DSAs) showed that IgM-type HLA-specific Abs were detected mainly from the culture supernatants from PBMCs of patients with stable graft function, whereas IgG isotype HLA Abs were detectable only from patients with biopsy-proven antibody-mediated rejection. In other words, these IgG isotype Abs also represented an activated humoral immune response in vivo . Additionally, IgM- and IgG-expressing mBCs from healthy donors ( n  = 5) were cultured with IL-21, CpG-ODN, and a supernatant produced by stimulating CD19 + B-cell-depleted PBMCs with PHA-L and PMA in 24-well flat-bottom plates (1 × 10 5  cells/well), and the resulting in vitro analysis provided

  4. Rapid method for direct identification of bacteria in urine and blood culture samples by matrix-assisted laser desorption ionization time-of-flight mass spectrometry: intact cell vs. extraction method.

    PubMed

    Ferreira, L; Sánchez-Juanes, F; Muñoz-Bellido, J L; González-Buitrago, J M

    2011-07-01

    Matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) is a fast and reliable technology for the identification of microorganisms with proteomics approaches. Here, we compare an intact cell method and a protein extraction method before application on the MALDI plate for the direct identification of microorganisms in both urine and blood culture samples from clinical microbiology laboratories. The results show that the intact cell method provides excellent results for urine and is a good initial method for blood cultures. The extraction method complements the intact cell method, improving microorganism identification from blood culture. Thus, we consider that MALDI-TOF MS performed directly on urine and blood culture samples, with the protocols that we propose, is a suitable technique for microorganism identification, as compared with the routine methods used in the clinical microbiology laboratory. © 2010 The Authors. Clinical Microbiology and Infection © 2010 European Society of Clinical Microbiology and Infectious Diseases.

  5. Avoiding full corrections in dynamic SPECT images impacts the performance of SPECT myocardial blood flow quantitation.

    PubMed

    Wang, Lei; Wu, Dayong; Yang, Yong; Chen, Ing-Jou; Lin, Chih-Yuan; Hsu, Bailing; Fang, Wei; Tang, Yi-Da

    2017-08-01

    This study investigated the performance of SPECT myocardial blood flow (MBF) quantitation lacking full physical corrections (All Corr) in dynamic SPECT (DySPECT) images. Eleven healthy normal volunteers (HVT) and twenty-four patients with angiography-documented CAD were assessed. All Corr in 99m Tc-sestamibi DySPECT encompassed noise reduction (NR), resolution recovery (RR), and corrections for scatter (SC) and attenuation (AC), otherwise no correction (NC) or only partial corrections. The performance was evaluated by quality index (R 2 ) and blood-pool spillover index (FBV) in kinetic modeling, and by rest flow (RMBF) and stress flow (SMBF) compared with those of All Corr. In HVT group, NC diminished 2-fold flow uniformity with the most degraded quality (15%-18% reduced R 2 ) and elevated spillover effect (45%-50% increased FBV). Consistently higher RMBF and SMBF were discovered in both groups (HVT 1.54/2.31 higher; CAD 1.60/1.72; all P < .0001). Bland-Altman analysis revealed positive flow bias (HVT 0.9-2.6 mL/min/g; CAD 0.7-1.3) with wide ranges of 95% CI of agreement (HVT NC -1.9-7.1; NR -0.4-4.4; NR + SC -1.1-4.3; NR + SC + RR -0.7-2.5) (CAD NC -1.2-3.8; NR -1.0-2.8; NR + SC -1.0-2.5; NR + SC + RR -1.1-2.6). Uncorrected physical interference in DySPECT images can extensively impact the performance of MBF quantitation. Full physical corrections should be considered to warrant this tool for clinical utilization.

  6. Correlation between quantitative PCR and Culture-Based methods for measuring Enterococcus spp. over various temporal scales at three California marine beaches

    EPA Science Inventory

    Several studies have examined how fecal indicator bacteria (FIB) measurements compare between quantitative polymerase chain reaction (QPCR) and the culture methods it is intended to replace. Here we extend those studies by examining the stability of that relationship within a be...

  7. Early identification of microorganisms in blood culture prior to the detection of a positive signal in the BACTEC FX system using matrix-assisted laser desorption/ionization-time of flight mass spectrometry.

    PubMed

    Wang, Ming-Cheng; Lin, Wei-Hung; Yan, Jing-Jou; Fang, Hsin-Yi; Kuo, Te-Hui; Tseng, Chin-Chung; Wu, Jiunn-Jong

    2015-08-01

    Matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) is a valuable method for rapid identification of blood stream infection (BSI) pathogens. Integration of MALDI-TOF MS and blood culture system can speed the identification of causative BSI microorganisms. We investigated the minimal microorganism concentrations of common BSI pathogens required for positive blood culture using BACTEC FX and for positive identification using MALDI-TOF MS. The time to detection with positive BACTEC FX and minimal incubation time with positive MALDI-TOF MS identification were determined for earlier identification of common BSI pathogens. The minimal microorganism concentrations required for positive blood culture using BACTEC FX were >10(7)-10(8) colony forming units/mL for most of the BSI pathogens. The minimal microorganism concentrations required for identification using MALDI-TOF MS were > 10(7) colony forming units/mL. Using simulated BSI models, one can obtain enough bacterial concentration from blood culture bottles for successful identification of five common Gram-positive and Gram-negative bacteria using MALDI-TOF MS 1.7-2.3 hours earlier than the usual time to detection in blood culture systems. This study provides an approach to earlier identification of BSI pathogens prior to the detection of a positive signal in the blood culture system using MALDI-TOF MS, compared to current methods. It can speed the time for identification of BSI pathogens and may have benefits of earlier therapy choice and on patient outcome. Copyright © 2013. Published by Elsevier B.V.

  8. Design of a Tablet Computer App for Facilitation of a Molecular Blood Culture Test in Clinical Microbiology and Preliminary Usability Evaluation.

    PubMed

    Samson, Lasse L; Pape-Haugaard, Louise; Meltzer, Michelle C; Fuchs, Martin; Schønheyder, Henrik C; Hejlesen, Ole

    2016-03-18

    User mobility is an important aspect of the development of clinical information systems for health care professionals. Mobile phones and tablet computers have obtained widespread use by health care professionals, offering an opportunity for supporting the access to patient information through specialized applications (apps) while supporting the mobility of the users. The use of apps for mobile phones and tablet computers may support workflow of complex tasks, for example, molecular-based diagnostic tests in clinical microbiology. Multiplex Blood Culture Test (MuxBCT) is a molecular-based diagnostic test used for rapid identification of pathogens in positive blood cultures. To facilitate the workflow of the MuxBCT, a specialized tablet computer app was developed as an accessory to the diagnostic test. The app aims to reduce the complexity of the test by step-by-step guidance of microscopy and to assist users in reaching an exact bacterial or fungal diagnosis based on blood specimen observations and controls. Additionally, the app allows for entry of test results, and communication thereof to the laboratory information system (LIS). The objective of the study was to describe the design considerations of the MuxBCT app and the results of a preliminary usability evaluation. The MuxBCT tablet app was developed and set up for use in a clinical microbiology laboratory. A near-live simulation study was conducted in the clinical microbiology laboratory to evaluate the usability of the MuxBCT app. The study was designed to achieve a high degree of realism as participants carried out a scenario representing the context of use for the MuxBCT app. As the MuxBCT was under development, the scenario involved the use of molecular blood culture tests similar to the MuxBCT for identification of microorganisms from positive blood culture samples. The study participants were observed, and their interactions with the app were recorded. After the study, the participants were debriefed to

  9. Design of a Tablet Computer App for Facilitation of a Molecular Blood Culture Test in Clinical Microbiology and Preliminary Usability Evaluation

    PubMed Central

    Pape-Haugaard, Louise; Meltzer, Michelle C; Fuchs, Martin; Schønheyder, Henrik C; Hejlesen, Ole

    2016-01-01

    Background User mobility is an important aspect of the development of clinical information systems for health care professionals. Mobile phones and tablet computers have obtained widespread use by health care professionals, offering an opportunity for supporting the access to patient information through specialized applications (apps) while supporting the mobility of the users. The use of apps for mobile phones and tablet computers may support workflow of complex tasks, for example, molecular-based diagnostic tests in clinical microbiology. Multiplex Blood Culture Test (MuxBCT) is a molecular-based diagnostic test used for rapid identification of pathogens in positive blood cultures. To facilitate the workflow of the MuxBCT, a specialized tablet computer app was developed as an accessory to the diagnostic test. The app aims to reduce the complexity of the test by step-by-step guidance of microscopy and to assist users in reaching an exact bacterial or fungal diagnosis based on blood specimen observations and controls. Additionally, the app allows for entry of test results, and communication thereof to the laboratory information system (LIS). Objective The objective of the study was to describe the design considerations of the MuxBCT app and the results of a preliminary usability evaluation. Methods The MuxBCT tablet app was developed and set up for use in a clinical microbiology laboratory. A near-live simulation study was conducted in the clinical microbiology laboratory to evaluate the usability of the MuxBCT app. The study was designed to achieve a high degree of realism as participants carried out a scenario representing the context of use for the MuxBCT app. As the MuxBCT was under development, the scenario involved the use of molecular blood culture tests similar to the MuxBCT for identification of microorganisms from positive blood culture samples. The study participants were observed, and their interactions with the app were recorded. After the study, the

  10. Dual-wavelength excitation to reduce background fluorescence for fluorescence spectroscopic quantitation of erythrocyte zinc protoporphyrin-IX and protoporphyrin-IX from whole blood and oral mucosa

    NASA Astrophysics Data System (ADS)

    Hennig, Georg; Vogeser, Michael; Holdt, Lesca M.; Homann, Christian; Großmann, Michael; Stepp, Herbert; Gruber, Christian; Erdogan, Ilknur; Hasmüller, Stephan; Hasbargen, Uwe; Brittenham, Gary M.

    2014-02-01

    Erythrocyte zinc protoporphyrin-IX (ZnPP) and protoporphyrin-IX (PPIX) accumulate in a variety of disorders that restrict or disrupt the biosynthesis of heme, including iron deficiency and various porphyrias. We describe a reagent-free spectroscopic method based on dual-wavelength excitation that can measure simultaneously both ZnPP and PPIX fluorescence from unwashed whole blood while virtually eliminating background fluorescence. We further aim to quantify ZnPP and PPIX non-invasively from the intact oral mucosa using dual-wavelength excitation to reduce the strong tissue background fluorescence while retaining the faint porphyrin fluorescence signal originating from erythrocytes. Fluorescence spectroscopic measurements were made on 35 diluted EDTA blood samples using a custom front-face fluorometer. The difference spectrum between fluorescence at 425 nm and 407 nm excitation effectively eliminated background autofluorescence while retaining the characteristic porphyrin peaks. These peaks were evaluated quantitatively and the results compared to a reference HPLC-kit method. A modified instrument using a single 1000 μm fiber for light delivery and detection was used to record fluorescence spectra from oral mucosa. For blood measurements, the ZnPP and PPIX fluorescence intensities from the difference spectra correlated well with the reference method (ZnPP: Spearman's rho rs = 0.943, p < 0.0001; PPIX: rs = 0.959, p < 0.0001). In difference spectra from oral mucosa, background fluorescence was reduced significantly, while porphyrin signals remained observable. The dual-wavelength excitation method evaluates quantitatively the ZnPP/heme and PPIX/heme ratios from unwashed whole blood, simplifying clinical laboratory measurements. The difference technique reduces the background fluorescence from measurements on oral mucosa, allowing for future non-invasive quantitation of erythrocyte ZnPP and PPIX.

  11. Applicability of integrated cell culture reverse transcriptase quantitative PCR (ICC-RTqPCR) for the simultaneous detection of the four human enteric enterovirus species in disinfection studies

    EPA Science Inventory

    A newly developed integrated cell culture reverse transcriptase quantitative PCR (ICC-RTqPCR) method and its applicability in UV disinfection studies is described. This method utilizes a singular cell culture system coupled with four RTqPCR assays to detect infectious serotypes t...

  12. Quantitation of the enantiomers of tramadol and its three main metabolites in human whole blood using LC-MS/MS.

    PubMed

    Haage, Pernilla; Kronstrand, Robert; Carlsson, Björn; Kugelberg, Fredrik C; Josefsson, Martin

    2016-02-05

    The analgesic drug tramadol and its metabolites are chiral compounds, with the (+)- and (-)-enantiomers showing different pharmacological and toxicological effects. This novel enantioselective method, based on LC-MS/MS in reversed phase mode, enabled measurement of the parent compound and its three main metabolites O-desmethyltramadol, N-desmethyltramadol and N,O-didesmethyltramadol simultaneously. Whole blood samples of 0.5g were fortified with internal standards (tramadol-(13)C-D3 and O-desmethyl-cis-tramadol-D6) and extracted under basic conditions (pH 11) by liquid-liquid extraction. Chromatography was performed on a chiral alpha-1-acid glycoprotein (AGP) column preceded by an AGP guard column. The mobile phase consisted of 0.8% acetonitrile and 99.2% ammonium acetate (20mM, pH 7.2). A post-column infusion with 0.05% formic acid in acetonitrile was used to enhance sensitivity. Quantitation as well as enantiomeric ratio measurements were covered by quality controls. Validation parameters for all eight enantiomers included selectivity (high), matrix effects (no ion suppression/enhancement), calibration model (linear, weight 1/X(2), in the range of 0.25-250ng/g), limit of quantitation (0.125-0.50ng/g), repeatability (2-6%) and intermediate precision (2-7%), accuracy (83-114%), dilution integrity (98-115%), carry over (not exceeding 0.07%) and stability (stable in blood and extract). The method was applied to blood samples from a healthy volunteer administrated a single 100mg dose and to a case sample concerning an impaired driver, which confirmed its applicability in human pharmacokinetic studies as well as in toxicological and forensic investigations. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Quantitative model for the blood pressure-lowering interaction of valsartan and amlodipine.

    PubMed

    Heo, Young-A; Holford, Nick; Kim, Yukyung; Son, Mijeong; Park, Kyungsoo

    2016-12-01

    The objective of this study was to develop a population pharmacokinetic (PK) and pharmacodynamic (PD) model to quantitatively describe the antihypertensive effect of combined therapy with amlodipine and valsartan. PK modelling was used with data collected from 48 healthy volunteers receiving a single dose of combined formulation of 10 mg amlodipine and 160 mg valsartan. Systolic (SBP) and diastolic blood pressure (DBP) were recorded during combined administration. SBP and DBP data for each drug alone were gathered from the literature. PKPD models of each drug and for combined administration were built with NONMEM 7.3. A two-compartment model with zero order absorption best described the PK data of both drugs. Amlodipine and valsartan monotherapy effects on SBP and DBP were best described by an I max model with an effect compartment delay. Combined therapy was described using a proportional interaction term as follows: (D 1  + D 2 ) +ALPHA×(D 1 × D 2 ). D 1 and D 2 are the predicted drug effects of amlodipine and valsartan monotherapy respectively. ALPHA is the interaction term for combined therapy. Quantitative estimates of ALPHA were -0.171 (95% CI: -0.218, -0.143) for SBP and -0.0312 (95% CI: -0.07739, -0.00283) for DBP. These infra-additive interaction terms for both SBP and DBP were consistent with literature results for combined administration of drugs in these classes. PKPD models for SBP and DBP successfully described the time course of the antihypertensive effects of amlodipine and valsartan. An infra-additive interaction between amlodipine and valsartan when used in combined administration was confirmed and quantified. © 2016 The British Pharmacological Society.

  14. Quantitative model for the blood pressure‐lowering interaction of valsartan and amlodipine

    PubMed Central

    Heo, Young‐A; Holford, Nick; Kim, Yukyung; Son, Mijeong

    2016-01-01

    Aims The objective of this study was to develop a population pharmacokinetic (PK) and pharmacodynamic (PD) model to quantitatively describe the antihypertensive effect of combined therapy with amlodipine and valsartan. Methods PK modelling was used with data collected from 48 healthy volunteers receiving a single dose of combined formulation of 10 mg amlodipine and 160 mg valsartan. Systolic (SBP) and diastolic blood pressure (DBP) were recorded during combined administration. SBP and DBP data for each drug alone were gathered from the literature. PKPD models of each drug and for combined administration were built with NONMEM 7.3. Results A two‐compartment model with zero order absorption best described the PK data of both drugs. Amlodipine and valsartan monotherapy effects on SBP and DBP were best described by an I max model with an effect compartment delay. Combined therapy was described using a proportional interaction term as follows: (D1 + D2) +ALPHA×(D1 × D2). D1 and D2 are the predicted drug effects of amlodipine and valsartan monotherapy respectively. ALPHA is the interaction term for combined therapy. Quantitative estimates of ALPHA were −0.171 (95% CI: −0.218, −0.143) for SBP and −0.0312 (95% CI: −0.07739, −0.00283) for DBP. These infra‐additive interaction terms for both SBP and DBP were consistent with literature results for combined administration of drugs in these classes. Conclusion PKPD models for SBP and DBP successfully described the time course of the antihypertensive effects of amlodipine and valsartan. An infra‐additive interaction between amlodipine and valsartan when used in combined administration was confirmed and quantified. PMID:27504853

  15. Preliminary Discussion On The Three Dimensional Space Quantitative Analysis Of Erythrocytes By SEMP And Some Applications On The Clinic And Research Of Blood Disease.

    NASA Astrophysics Data System (ADS)

    Lian-Huang, Lu; Wen-Meng, Tong; Zhi-Jun, Zhang; Gui-Huan, He; Su-Hui, Huan

    1989-04-01

    The abnormity of the quality and quantity for erythrocytes is one of the important changes of blood disease. It shows the abnormal blood-making function of human body. Therefore, the study of the change of shape of erythrocytes is the indispensible and important basis of reference in the clinic, diagnose and research of blood disease. In this paper, a preliminary discussion is made on the acquisition of scanning stereographs for erythrocytes, the application of the theory of photographic measurement on the three dimensional space quantitative analysis of erythrocytes, drawings of isoline map and section map of various erythrocytes for normal persons, paroxysmal nocturanal hemoglobinuria (PNH) patients and aplastic anemia patients, study of the shape characteristics of normal erythrocytes and various abnormal erytnrocytes and the applications in clinic, diagnose and research. This research is a combination of microphotogrammetry and erythrocyte morphology. It is polssible to push fotward the study of erythrocyte morphology from LM, SEM to a higher stage of scanning electron micrographic photogrammetry(SEMP) for stereograpic observationand three diamensional quantitative analysis to explore a new path for the further study of the shape of erthrocytes.

  16. Rapid identification of moulds and arthroconidial yeasts from positive blood cultures by MALDI-TOF mass spectrometry.

    PubMed

    de Almeida, João N; Sztajnbok, Jaques; da Silva, Afonso Rafael; Vieira, Vinicius Adriano; Galastri, Anne Layze; Bissoli, Leandro; Litvinov, Nadia; Del Negro, Gilda Maria Barbaro; Motta, Adriana Lopes; Rossi, Flávia; Benard, Gil

    2016-11-01

    Moulds and arthroconidial yeasts are potential life-threatening agents of fungemia in immunocompromised patients. Fast and accurate identification (ID) of these pathogens hastens initiation of targeted antifungal therapy, thereby improving the patients' prognosis. We describe a new strategy that enabled the identification of moulds and arthroconidial yeasts directly from positive blood cultures by MALDI-TOF mass spectrometry (MS). Positive blood cultures (BCs) with Gram staining showing hyphae and/or arthroconidia were prospectively selected and submitted to an in-house protein extraction protocol. Mass spectra were obtained by Vitek MS™ system, and identifications were carried out with in the research use only (RUO) mode with an extended database (SARAMIS™ [v.4.12] plus in-house database). Fusarium solani, Fusarium verticillioides, Exophiala dermatitidis, Saprochaete clavata, and Trichosporon asahii had correct species ID by MALDI-TOF MS analysis of positive BCs. All cases were related to critically ill patients with high mortality fungemia and direct ID from positive BCs was helpful for rapid administration of targeted antifungal therapy. © The Author 2016. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  17. Long-term culture of chicken primordial germ cells isolated from embryonic blood and production of germline chimaeric chickens.

    PubMed

    Naito, Mitsuru; Harumi, Takashi; Kuwana, Takashi

    2015-02-01

    Production of germline chimaeric chickens by the transfer of cultured primordial germ cells (PGC) is a useful system for germline manipulation. A novel culture system was developed for chicken PGC isolated from embryonic blood. The isolated PGC were cultured on feeder cells derived from chicken embryonic fibroblast. The cultured PGC formed colonies and they proliferated about 300-times during the first 30 days. The cultured PGC retained the ability to migrate to recipient gonads and were also chicken VASA homologue (CVH)-positive. Female PGC were present in the mixed-sex PGC populations cultured for more than 90 days and gave rise to viable offspring efficiently via germline chimaeric chickens. Male cultured PGC were transferred to recipient embryos and produced putative chimaeric chickens. The DNA derived from the cultured PGC was detected in the sperm samples of male putative chimaeric chickens, but no donor derived offspring were obtained. Donor-derived offspring were also obtained from germline chimaeric chickens by the transfer of frozen-thawed cultured PGC. The culture method for PGC developed in the present study is useful for manipulation of the germline in chickens, such as preservation of genetic resources and gene transfer. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Mesenchymal stem cells from the Wharton’s jelly of umbilical cord segments provide stromal support for the maintenance of cord blood hematopoietic stem cells during long-term ex vivo culture

    PubMed Central

    Bakhshi, Tiki; Zabriskie, Ryan C.; Bodie, Shamanique; Kidd, Shannon; Ramin, Susan; Paganessi, Laura A.; Gregory, Stephanie A.; Fung, Henry C.; Christopherson, Kent W.

    2012-01-01

    BACKGROUND Hematopoietic stem cells (HSCs) are routinely obtained from marrow, mobilized peripheral blood, and umbilical cord blood. Mesenchymal stem cells (MSCs) are traditionally isolated from marrow. Bone marrow–derived MSCs (BM-MSCs) have previously demonstrated their ability to act as a feeder layer in support of ex vivo cord blood expansion. However, the use of BM-MSCs to support the growth, differentiation, and engraftment of cord blood may not be ideal for transplant purposes. Therefore, the potential of MSCs from a novel source, the Wharton’s jelly of umbilical cords, to act as stromal support for the long-term culture of cord blood HSC was evaluated. STUDY DESIGN AND METHODS Umbilical cord–derived MSCs (UC-MSCs) were cultured from the Wharton’s jelly of umbilical cord segments. The UC-MSCs were then profiled for expression of 12 cell surface receptors and tested for their ability to support cord blood HSCs in a long-term culture-initiating cell (LTC-IC) assay. RESULTS Upon culture, UC-MSCs express a defined set of cell surface markers (CD29, CD44, CD73, CD90, CD105, CD166, and HLA-A) and lack other markers (CD45, CD34, CD38, CD117, and HLA-DR) similar to BM-MSCs. Like BM-MSCs, UC-MSCs effectively support the growth of CD34+ cord blood cells in LTC-IC assays. CONCLUSION These data suggest the potential therapeutic application of Wharton’s jelly–derived UC-MSCs to provide stromal support structure for the long-term culture of cord blood HSCs as well as the possibility of cotransplantation of genetically identical, HLA-matched, or unmatched cord blood HSCs and UC-MSCs in the setting of HSC transplantation. PMID:18798803

  19. LC–MS/MS Quantitation of Esophagus Disease Blood Serum Glycoproteins by Enrichment with Hydrazide Chemistry and Lectin Affinity Chromatography

    PubMed Central

    2015-01-01

    Changes in glycosylation have been shown to have a profound correlation with development/malignancy in many cancer types. Currently, two major enrichment techniques have been widely applied in glycoproteomics, namely, lectin affinity chromatography (LAC)-based and hydrazide chemistry (HC)-based enrichments. Here we report the LC–MS/MS quantitative analyses of human blood serum glycoproteins and glycopeptides associated with esophageal diseases by LAC- and HC-based enrichment. The separate and complementary qualitative and quantitative data analyses of protein glycosylation were performed using both enrichment techniques. Chemometric and statistical evaluations, PCA plots, or ANOVA test, respectively, were employed to determine and confirm candidate cancer-associated glycoprotein/glycopeptide biomarkers. Out of 139, 59 common glycoproteins (42% overlap) were observed in both enrichment techniques. This overlap is very similar to previously published studies. The quantitation and evaluation of significantly changed glycoproteins/glycopeptides are complementary between LAC and HC enrichments. LC–ESI–MS/MS analyses indicated that 7 glycoproteins enriched by LAC and 11 glycoproteins enriched by HC showed significantly different abundances between disease-free and disease cohorts. Multiple reaction monitoring quantitation resulted in 13 glycopeptides by LAC enrichment and 10 glycosylation sites by HC enrichment to be statistically different among disease cohorts. PMID:25134008

  20. Comparative evaluation of Oxoid Signal and BACTEC radiometric blood culture systems for the detection of bacteremia and fungemia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weinstein, M.P.; Mirrett, S.; Reller, L.B.

    1988-05-01

    The Oxoid Signal blood culture system is a newly described, innovative method for visually detecting growth of microorganisms. We did 5,999 paired comparisons of equal volumes (10 ml) of blood in the Oxoid Signal and BACTEC radiometric blood culture systems at two university hospitals that use identical methods of obtaining and processing specimens. Overall, more microorganisms were detected in the BACTEC system (P less than 0.001), in particular, streptococci (P less than 0.01), fungi (P less than 0.001), and nonfermentative gram-negative rods, especially Acinetobacter species (P less than 0.001). Trends favoring the BACTEC system for detection of Pseudomonas aeruginosa, Haemophilusmore » species, and Neisseria species were noted. There were no differences in the yield of staphylococci, members of the family Enterobacteriaceae, and anaerobic bacteria. When both systems detected sepsis, the BACTEC did so earlier (P less than 0.001). This advantage was most notable at 24 h (70% of BACTEC positives detected versus 48% of Oxoid positives). The proportion of positives detected after 48 h, however, was similar (BACTEC, 84%; Oxoid, 78%). Revisions in the Oxoid Signal system itself or in the processing of Oxoid bottles appear to be necessary to improve its performance in detecting certain microorganism groups, especially fungi.« less

  1. Culture-free, highly sensitive, quantitative detection of bacteria from minimally processed samples using fluorescence imaging by smartphone.

    PubMed

    Shrivastava, Sajal; Lee, Won-Il; Lee, Nae-Eung

    2018-06-30

    A critical unmet need in the diagnosis of bacterial infections, which remain a major cause of human morbidity and mortality, is the detection of scarce bacterial pathogens in a variety of samples in a rapid and quantitative manner. Herein, we demonstrate smartphone-based detection of Staphylococcus aureus in a culture-free, rapid, quantitative manner from minimally processed liquid samples using aptamer-functionalized fluorescent magnetic nanoparticles. The tagged S. aureus cells were magnetically captured in a detection cassette, and then fluorescence was imaged using a smartphone camera with a light-emitting diode as the excitation source. Our results showed quantitative detection capability with a minimum detectable concentration as low as 10 cfu/ml by counting individual bacteria cells, efficiently capturing S. aureus cells directly from a peanut milk sample within 10 min. When the selectivity of detection was investigated using samples spiked with other pathogenic bacteria, no significant non-specific detection occurred. Furthermore, strains of S. aureus from various origins showed comparable results, ensuring that the approach can be widely adopted. Therefore, the quantitative fluorescence imaging platform on a smartphone could allow on-site detection of bacteria, providing great potential assistance during major infectious disease outbreaks in remote and resource-limited settings. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Acceptability and feasibility of a culturally tailored Internet-delivered intervention to promote blood donation in Blacks.

    PubMed

    Robbins, Mark L; Paiva, Andrea L; Amoyal, Nicole R; Brick, Leslie; Kessler, Debra A; Burditt, Caitlin; Caltabiano, Melinda; Shaz, Beth H

    2015-03-01

    A pilot test of a computer-tailored intervention designed to promote blood donation among Blacks was conducted. Intervention content, based on the transtheoretical model, offered participants individually and culturally tailored information on blood donation with emphasis on need specific to race (e.g., sickle-cell disease). Black adults (N = 150) with a diversity of blood donation experience were recruited from a blood center and a survey recruitment website. Posttest assessment included a 14-item evaluation and transtheoretical model questions. Participants rated the program positively (81.3% to 98.7% of participants agreeing or strongly agreeing with evaluation items). For example, 98.7% of respondents reported that the program gave sound advice and that personal feedback was easily understood, and 87.3% felt the program was designed for people like themselves. Ninety-five percent of participants reported that they would recommend the program to others. There were no significant differences in ratings based on demographics. Qualitative responses support program acceptability. Furthermore, pre- and postprogram assessments indicated an increase in intention to donate, t(149) = 3.56, p = .001, d = .29. With acceptability and feasibility confirmed, the next steps are to test efficacy and cost-effectiveness for use to increase blood donation, particularly in priority populations. © 2014 Society for Public Health Education.

  3. Quantitative myocardial blood flow imaging with integrated time-of-flight PET-MR.

    PubMed

    Kero, Tanja; Nordström, Jonny; Harms, Hendrik J; Sörensen, Jens; Ahlström, Håkan; Lubberink, Mark

    2017-12-01

    The use of integrated PET-MR offers new opportunities for comprehensive assessment of cardiac morphology and function. However, little is known on the quantitative accuracy of cardiac PET imaging with integrated time-of-flight PET-MR. The aim of the present work was to validate the GE Signa PET-MR scanner for quantitative cardiac PET perfusion imaging. Eleven patients (nine male; mean age 59 years; range 46-74 years) with known or suspected coronary artery disease underwent 15 O-water PET scans at rest and during adenosine-induced hyperaemia on a GE Discovery ST PET-CT and a GE Signa PET-MR scanner. PET-MR images were reconstructed using settings recommended by the manufacturer, including time-of-flight (TOF). Data were analysed semi-automatically using Cardiac VUer software, resulting in both parametric myocardial blood flow (MBF) images and segment-based MBF values. Correlation and agreement between PET-CT-based and PET-MR-based MBF values for all three coronary artery territories were assessed using regression analysis and intra-class correlation coefficients (ICC). In addition to the cardiac PET-MR reconstruction protocol as recommended by the manufacturer, comparisons were made using a PET-CT resolution-matched reconstruction protocol both without and with TOF to assess the effect of time-of-flight and reconstruction parameters on quantitative MBF values. Stress MBF data from one patient was excluded due to movement during the PET-CT scanning. Mean MBF values at rest and stress were (0.92 ± 0.12) and (2.74 ± 1.37) mL/g/min for PET-CT and (0.90 ± 0.23) and (2.65 ± 1.15) mL/g/min for PET-MR (p = 0.33 and p = 0.74). ICC between PET-CT-based and PET-MR-based regional MBF was 0.98. Image quality was improved with PET-MR as compared to PET-CT. ICC between PET-MR-based regional MBF with and without TOF and using different filter and reconstruction settings was 1.00. PET-MR-based MBF values correlated well with PET-CT-based MBF values and

  4. Comparison of the detection of periodontal pathogens in bacteraemia after tooth brushing by culture and molecular techniques.

    PubMed

    Marín, M-J; Figuero, E; González, I; O'Connor, A; Diz, P; Álvarez, M; Herrera, D; Sanz, M

    2016-05-01

    The prevalence and amounts of periodontal pathogens detected in bacteraemia samples after tooth brushing-induced by means of four diagnostic technique, three based on culture and one in a molecular-based technique, have been compared in this study. Blood samples were collected from thirty-six subjects with different periodontal status (17 were healthy, 10 with gingivitis and 9 with periodontitis) at baseline and 2 minutes after tooth brushing. Each sample was analyzed by three culture-based methods [direct anaerobic culturing (DAC), hemo-culture (BACTEC), and lysis-centrifugation (LC)] and one molecular-based technique [quantitative polymerase chain reaction (qPCR)]. With culture any bacterial isolate was detected and quantified, while with qPCR only Porphyromonas gingivalis and Aggregatibacter actinomycetemcomitans were detected and quantified. Descriptive analyses, ANOVA and Chi-squared tests, were performed. Neither BACTEC nor qPCR detected any type of bacteria in the blood samples. Only LC (2.7%) and DAC (8.3%) detected bacteraemia, although not in the same patients. Fusobacterium nucleatum was the most frequently detected bacterial species. The disparity in the results when the same samples were analyzed with four different microbiological detection methods highlights the need for a proper validation of the methodology to detect periodontal pathogens in bacteraemia samples, mainly when the presence of periodontal pathogens in blood samples after tooth brushing was very seldom.

  5. Comparative analysis of Gram's stain, PNA-FISH and Sepsityper with MALDI-TOF MS for the identification of yeast direct from positive blood cultures.

    PubMed

    Gorton, Rebecca L; Ramnarain, P; Barker, K; Stone, N; Rattenbury, S; McHugh, T D; Kibbler, C C

    2014-10-01

    Fungaemia diagnosis could be improved by reducing the time to identification of yeast from blood cultures. This study aimed to evaluate three rapid methods for the identification of yeast direct from blood cultures; Gram's stain analysis, the AdvanDX Peptide Nucleic Acid in Situ Hybridisation Yeast Traffic Light system (PNA-FISH YTL) and Bruker Sepsityper alongside matrix-assisted laser desorption ionisation time of flight mass spectrometry (MALDI-TOF MS). Fifty blood cultures spiked with a known single yeast strain were analysed by blinded operators experienced in each method. Identifications were compared with MALDI-TOF MS CHROMagar Candida culture and ITS rRNA sequence-based identifications. On first attempt, success rates of 96% (48/50) and 76% (36/50) were achieved using PNA-FISH YTL and Gram's stain respectively. MALDI-TOF MS demonstrated a success rate of 56% (28/50) when applying manufacturer's species log score thresholds and 76% (38/50) using in-house parameters, including lowering the species log score threshold to >1.5. In conclusion, PNA-FISH YTL demonstrated a high success rate successfully identifying yeast commonly encountered in fungaemia. Sepsityper(™) with MALDI-TOF MS was accurate but increased sensitivity is required. Due to the misidentification of commonly encountered yeast Gram's stain analysis demonstrated limited utility in this setting. © 2014 Blackwell Verlag GmbH.

  6. Direct identification of microorganisms from positive blood cultures using the lysis-filtration technique and matrix assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS): a multicentre study.

    PubMed

    Farina, Claudio; Arena, Fabio; Casprini, Patrizia; Cichero, Paola; Clementi, Massimo; Cosentino, Marina; Degl'Innocenti, Roberto; Giani, Tommaso; Luzzaro, Francesco; Mattei, Romano; Mauri, Carola; Nardone, Maria; Rossolini, Gian Maria; Serna Ortega, Paula Andrea; Vailati, Francesca

    2015-04-01

    Microbial identification from blood cultures is essential to institute optimal antibiotic therapy and improve survival possibilities. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been successfully applied to identify bacteria and yeasts from positive blood cultures broths. The aim of this multicentre study was to evaluate the reliability of the lysis-filtration technique associated with MALDI-TOF MS to directly identify microorganisms from 765 positive blood cultures collected in six Italian hospitals. Overall, 675/765 (78.1%) blood isolates were correctly identified at the species level, with significant differences between Gram-negative and Gram-positive bacteria (92.6%, and 69.8%, respectively). Some difficulties arise in identifying Streptococcus pneumoniae, Staphylococcus aureus, yeasts and anaerobes. The lysis-filtration protocol is a suitable procedure in terms of performance in identifying microorganisms, but it is quite expensive and technically time-consuming since the time of filtration is not regular for all the samples. The application of the MALDI-TOF MS technique to the direct microbial identification from positive blood cultures is a very promising approach, even if more experience must be gained to minimize errors and costs.

  7. Predicting human blood viscosity in silico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fedosov, Dmitry A.; Pan, Wenxiao; Caswell, Bruce

    2011-07-05

    Cellular suspensions such as blood are a part of living organisms and their rheological and flow characteristics determine and affect majority of vital functions. The rheological and flow properties of cell suspensions are determined by collective dynamics of cells, their structure or arrangement, cell properties and interactions. We study these relations for blood in silico using a mesoscopic particle-based method and two different models (multi-scale/low-dimensional) of red blood cells. The models yield accurate quantitative predictions of the dependence of blood viscosity on shear rate and hematocrit. We explicitly model cell aggregation interactions and demonstrate the formation of reversible rouleaux structuresmore » resulting in a tremendous increase of blood viscosity at low shear rates and yield stress, in agreement with experiments. The non-Newtonian behavior of such cell suspensions (e.g., shear thinning, yield stress) is analyzed and related to the suspension’s microstructure, deformation and dynamics of single cells. We provide the flrst quantitative estimates of normal stress differences and magnitude of aggregation forces in blood. Finally, the flexibility of the cell models allows them to be employed for quantitative analysis of a much wider class of complex fluids including cell, capsule, and vesicle suspensions.« less

  8. Quantitative measurement of mitochondrial membrane potential in cultured cells: calcium-induced de- and hyperpolarization of neuronal mitochondria

    PubMed Central

    Gerencser, Akos A; Chinopoulos, Christos; Birket, Matthew J; Jastroch, Martin; Vitelli, Cathy; Nicholls, David G; Brand, Martin D

    2012-01-01

    Mitochondrial membrane potential (ΔΨM) is a central intermediate in oxidative energy metabolism. Although ΔΨM is routinely measured qualitatively or semi-quantitatively using fluorescent probes, its quantitative assay in intact cells has been limited mostly to slow, bulk-scale radioisotope distribution methods. Here we derive and verify a biophysical model of fluorescent potentiometric probe compartmentation and dynamics using a bis-oxonol-type indicator of plasma membrane potential (ΔΨP) and the ΔΨM probe tetramethylrhodamine methyl ester (TMRM) using fluorescence imaging and voltage clamp. Using this model we introduce a purely fluorescence-based quantitative assay to measure absolute values of ΔΨM in millivolts as they vary in time in individual cells in monolayer culture. The ΔΨP-dependent distribution of the probes is modelled by Eyring rate theory. Solutions of the model are used to deconvolute ΔΨP and ΔΨM in time from the probe fluorescence intensities, taking into account their slow, ΔΨP-dependent redistribution and Nernstian behaviour. The calibration accounts for matrix:cell volume ratio, high- and low-affinity binding, activity coefficients, background fluorescence and optical dilution, allowing comparisons of potentials in cells or cell types differing in these properties. In cultured rat cortical neurons, ΔΨM is −139 mV at rest, and is regulated between −108 mV and −158 mV by concerted increases in ATP demand and Ca2+-dependent metabolic activation. Sensitivity analysis showed that the standard error of the mean in the absolute calibrated values of resting ΔΨM including all biological and systematic measurement errors introduced by the calibration parameters is less than 11 mV. Between samples treated in different ways, the typical equivalent error is ∼5 mV. PMID:22495585

  9. Beyond Blood Culture and Gram Stain Analysis: A Review of Molecular Techniques for the Early Detection of Bacteremia in Surgical Patients.

    PubMed

    Scerbo, Michelle H; Kaplan, Heidi B; Dua, Anahita; Litwin, Douglas B; Ambrose, Catherine G; Moore, Laura J; Murray, Col Clinton K; Wade, Charles E; Holcomb, John B

    2016-06-01

    Sepsis from bacteremia occurs in 250,000 cases annually in the United States, has a mortality rate as high as 60%, and is associated with a poorer prognosis than localized infection. Because of these high figures, empiric antibiotic administration for patients with systemic inflammatory response syndrome (SIRS) and suspected infection is the second most common indication for antibiotic administration in intensive care units (ICU)s. However, overuse of empiric antibiotics contributes to the development of opportunistic infections, antibiotic resistance, and the increase in multi-drug-resistant bacterial strains. The current method of diagnosing and ruling out bacteremia is via blood culture (BC) and Gram stain (GS) analysis. Conventional and molecular methods for diagnosing bacteremia were reviewed and compared. The clinical implications, use, and current clinical trials of polymerase chain reaction (PCR)-based methods to detect bacterial pathogens in the blood stream were detailed. BC/GS has several disadvantages. These include: some bacteria do not grow in culture media; others do not GS appropriately; and cultures can require up to 5 d to guide or discontinue antibiotic treatment. PCR-based methods can be potentially applied to detect rapidly, accurately, and directly microbes in human blood samples. Compared with the conventional BC/GS, particular advantages to molecular methods (specifically, PCR-based methods) include faster results, leading to possible improved antibiotic stewardship when bacteremia is not present.

  10. Synthesis strategy: building a culturally sensitive mid-range theory of risk perception using literary, quantitative, and qualitative methods.

    PubMed

    Siaki, Leilani A; Loescher, Lois J; Trego, Lori L

    2013-03-01

    This article presents a discussion of development of a mid-range theory of risk perception. Unhealthy behaviours contribute to the development of health inequalities worldwide. The link between perceived risk and successful health behaviour change is inconclusive, particularly in vulnerable populations. This may be attributed to inattention to culture. The synthesis strategy of theory building guided the process using three methods: (1) a systematic review of literature published between 2000-2011 targeting perceived risk in vulnerable populations; (2) qualitative and (3) quantitative data from a study of Samoan Pacific Islanders at high risk of cardiovascular disease and diabetes. Main concepts of this theory include risk attention, appraisal processes, cognition, and affect. Overarching these concepts is health-world view: cultural ways of knowing, beliefs, values, images, and ideas. This theory proposes the following: (1) risk attention varies based on knowledge of the health risk in the context of health-world views; (2) risk appraisals are influenced by affect, health-world views, cultural customs, and protocols that intersect with the health risk; (3) strength of cultural beliefs, values, and images (cultural identity) mediate risk attention and risk appraisal influencing the likelihood that persons will engage in health-promoting behaviours that may contradict cultural customs/protocols. Interventions guided by a culturally sensitive mid-range theory may improve behaviour-related health inequalities in vulnerable populations. The synthesis strategy is an intensive process for developing a culturally sensitive mid-range theory. Testing of the theory will ascertain its usefulness for reducing health inequalities in vulnerable groups. © 2012 Blackwell Publishing Ltd.

  11. Microscope-integrated quantitative analysis of intraoperative indocyanine green fluorescence angiography for blood flow assessment: first experience in 30 patients.

    PubMed

    Kamp, Marcel A; Slotty, Philipp; Turowski, Bernd; Etminan, Nima; Steiger, Hans-Jakob; Hänggi, Daniel; Stummer, Walter

    2012-03-01

    Intraoperative measurements of cerebral blood flow are of interest during vascular neurosurgery. Near-infrared indocyanine green (ICG) fluorescence angiography was introduced for visualizing vessel patency intraoperatively. However, quantitative information has not been available. To report our experience with a microscope with an integrated dynamic ICG fluorescence analysis system supplying semiquantitative information on blood flow. We recorded ICG fluorescence curves of cortex and cerebral vessels using software integrated into the surgical microscope (Flow 800 software; Zeiss Pentero) in 30 patients undergoing surgery for different pathologies. The following hemodynamic parameters were assessed: maximum intensity, rise time, time to peak, time to half-maximal fluorescence, cerebral blood flow index, and transit times from arteries to cortex. For patients without obvious perfusion deficit, maximum fluorescence intensity was 177.7 arbitrary intensity units (AIs; 5-mg ICG bolus), mean rise time was 5.2 seconds (range, 2.9-8.2 seconds; SD, 1.3 seconds), mean time to peak was 9.4 seconds (range, 4.9-15.2 seconds; SD, 2.5 seconds), mean cerebral blood flow index was 38.6 AI/s (range, 13.5-180.6 AI/s; SD, 36.9 seconds), and mean transit time was 1.5 seconds (range, 360 milliseconds-3 seconds; SD, 0.73 seconds). For 3 patients with impaired cerebral perfusion, time to peak, rise time, and transit time between arteries and cortex were markedly prolonged (>20, >9 , and >5 seconds). In single patients, the degree of perfusion impairment could be quantified by the cerebral blood flow index ratios between normal and ischemic tissue. Transit times also reflected blood flow perturbations in arteriovenous fistulas. Quantification of ICG-based fluorescence angiography appears to be useful for intraoperative monitoring of arterial patency and regional cerebral blood flow.

  12. Dynamic quantitative analysis of adherent cell cultures by means of lens-free video microscopy

    NASA Astrophysics Data System (ADS)

    Allier, C.; Vincent, R.; Navarro, F.; Menneteau, M.; Ghenim, L.; Gidrol, X.; Bordy, T.; Hervé, L.; Cioni, O.; Bardin, S.; Bornens, M.; Usson, Y.; Morales, S.

    2018-02-01

    We present our implementation of lens-free video microscopy setup for the monitoring of adherent cell cultures. We use a multi-wavelength LED illumination together with a dedicated holographic reconstruction algorithm that allows for an efficient removal of twin images from the reconstructed phase image for densities up to those of confluent cell cultures (>500 cells/mm2). We thereby demonstrate that lens-free video microscopy, with a large field of view ( 30 mm2) can enable us to capture the images of thousands of cells simultaneously and directly inside the incubator. It is then possible to trace and quantify single cells along several cell cycles. We thus prove that lens-free microscopy is a quantitative phase imaging technique enabling estimation of several metrics at the single cell level as a function of time, for example the area, dry mass, maximum thickness, major axis length and aspect ratio of each cell. Combined with cell tracking, it is then possible to extract important parameters such as the initial cell dry mass (just after cell division), the final cell dry mass (just before cell division), the average cell growth rate, and the cell cycle duration. As an example, we discuss the monitoring of a HeLa cell cultures which provided us with a data-set featuring more than 10 000 cell cycle tracks and more than 2x106 cell morphological measurements in a single time-lapse.

  13. Novel, high-yield red blood cell production methods from CD34-positive cells derived from human embryonic stem, yolk sac, fetal liver, cord blood, and peripheral blood.

    PubMed

    Olivier, Emmanuel; Qiu, Caihong; Bouhassira, Eric E

    2012-08-01

    The current supply of red blood cells expressing rare blood groups is not sufficient to cover all the existing transfusion needs for chronically transfused patients, such as sickle cell disease homozygous carriers, because of alloimmunization. In vitro production of cultured red blood cells is slowly emerging as a possible complement to the existing collection-based red blood cell procurement system. The yield of cultured red blood cells can theoretically be maximized by amplifying the stem, progenitor, or precursor compartment. Here, we combined methods designed to expand these three compartments to optimize the yield of cultured red blood cells and found that exposing CD34(+) cells to a short pulse of cytokines favorable for erythroid differentiation prior to stem cell expansion followed by progenitor expansion produced the highest yield of erythroid cells. This novel serum-free red blood cell production protocol was efficient on CD34(+) cells derived from human embryonic stem cells, 6-8-week yolk sacs, 16-18-week fetal livers, cord blood, and peripheral blood. The yields of cells obtained with these new protocols were larger by an order of magnitude than the yields observed previously. Globin expression analysis by high-performance liquid chromatography revealed that these expansion protocols generally yielded red blood cells that expressed a globin profile similar to that expected for the developmental age of the CD34(+) cells.

  14. 3-D Ultrafast Doppler Imaging Applied to the Noninvasive and Quantitative Imaging of Blood Vessels in Vivo

    PubMed Central

    Provost, J.; Papadacci, C.; Demene, C.; Gennisson, J-L.; Tanter, M.; Pernot, M.

    2016-01-01

    Ultrafast Doppler Imaging was introduced as a technique to quantify blood flow in an entire 2-D field of view, expanding the field of application of ultrasound imaging to the highly sensitive anatomical and functional mapping of blood vessels. We have recently developed 3-D Ultrafast Ultrasound Imaging, a technique that can produce thousands of ultrasound volumes per second, based on three-dimensional plane and diverging wave emissions, and demonstrated its clinical feasibility in human subjects in vivo. In this study, we show that non-invasive 3-D Ultrafast Power Doppler, Pulsed Doppler, and Color Doppler Imaging can be used to perform quantitative imaging of blood vessels in humans when using coherent compounding of three-dimensional tilted plane waves. A customized, programmable, 1024-channel ultrasound system was designed to perform 3-D Ultrafast Imaging. Using a 32X32, 3-MHz matrix phased array (Vermon, France), volumes were beamformed by coherently compounding successive tilted plane wave emissions. Doppler processing was then applied in a voxel-wise fashion. 3-D Ultrafast Power Doppler Imaging was first validated by imaging Tygon tubes of varying diameter and its in vivo feasibility was demonstrated by imaging small vessels in the human thyroid. Simultaneous 3-D Color and Pulsed Doppler Imaging using compounded emissions were also applied in the carotid artery and the jugular vein in one healthy volunteer. PMID:26276956

  15. Evaluation of the default-mode network by quantitative 15O-PET: comparative study between cerebral blood flow and oxygen consumption.

    PubMed

    Aoe, Jo; Watabe, Tadashi; Shimosegawa, Eku; Kato, Hiroki; Kanai, Yasukazu; Naka, Sadahiro; Matsunaga, Keiko; Isohashi, Kayako; Tatsumi, Mitsuaki; Hatazawa, Jun

    2018-06-22

    Resting-state functional MRI (rs-fMRI) has revealed the existence of a default-mode network (DMN) based on spontaneous oscillations of the blood oxygenation level-dependent (BOLD) signal. The BOLD signal reflects the deoxyhemoglobin concentration, which depends on the relationship between the regional cerebral blood flow (CBF) and the cerebral metabolic rate of oxygen (CMRO 2 ). However, these two factors cannot be separated in BOLD rs-fMRI. In this study, we attempted to estimate the functional correlations in the DMN by means of quantitative 15 O-labeled gases and water PET, and to compare the contribution of the CBF and CMRO 2 to the DMN. Nine healthy volunteers (5 men and 4 women; mean age, 47.0 ± 1.2 years) were studied by means of 15 O-O 2 , 15 O-CO gases and 15 O-water PET. Quantitative CBF and CMRO 2 images were generated by an autoradiographic method and transformed into MNI standardized brain template. Regions of interest were placed on normalized PET images according to the previous rs-fMRI study. For the functional correlation analysis, the intersubject Pearson's correlation coefficients (r) were calculated for all pairs in the brain regions and correlation matrices were obtained for CBF and CMRO 2 , respectively. We defined r > 0.7 as a significant positive correlation and compared the correlation matrices of CBF and CMRO 2 . Significant positive correlations (r > 0.7) were observed in 24 pairs of brain regions for the CBF and 22 pairs of brain regions for the CMRO 2 . Among them, 12 overlapping networks were observed between CBF and CMRO 2 . Correlation analysis of CBF led to the detection of more brain networks as compared to that of CMRO 2 , indicating that the CBF can capture the state of the spontaneous activity with a higher sensitivity. We estimated the functional correlations in the DMN by means of quantitative PET using 15 O-labeled gases and water. The correlation matrix derived from the CBF revealed a larger number of brain

  16. Effectiveness of practices to reduce blood culture contamination: A Laboratory Medicine Best Practices systematic review and meta-analysis☆

    PubMed Central

    Snyder, Susan R.; Favoretto, Alessandra M.; Baetz, Rich Ann; Derzon, James H.; Madison, Bereneice M.; Mass, Diana; Shaw, Colleen S.; Layfield, Christopher D.; Christenson, Robert H.; Liebow, Edward B.

    2015-01-01

    Objectives This article is a systematic review of the effectiveness of three practices for reducing blood culture contamination rates: venipuncture, phlebotomy teams, and prepackaged preparation/collection (prep) kits. Design and methods The CDC-funded Laboratory Medicine Best Practices Initiative systematic review methods for quality improvement practices were used. Results Studies included as evidence were: 9 venipuncture (vs. versus intravenous catheter), 5 phlebotomy team; and 7 prep kit. All studies for venipuncture and phlebotomy teams favored these practices, with meta-analysis mean odds ratios for venipuncture of 2.69 and phlebotomy teams of 2.58. For prep kits 6 studies’ effect sizes were not statistically significantly different from no effect (meta-analysis mean odds ratio 1.12). Conclusions Venipuncture and the use of phlebotomy teams are effective practices for reducing blood culture contamination rates in diverse hospital settings and are recommended as evidence-based “best practices” with high overall strength of evidence and substantial effect size ratings. No recommendation is made for or against prep kits based on uncertain improvement. PMID:22709932

  17. Effectiveness of practices to reduce blood culture contamination: a Laboratory Medicine Best Practices systematic review and meta-analysis.

    PubMed

    Snyder, Susan R; Favoretto, Alessandra M; Baetz, Rich Ann; Derzon, James H; Madison, Bereneice M; Mass, Diana; Shaw, Colleen S; Layfield, Christopher D; Christenson, Robert H; Liebow, Edward B

    2012-09-01

    This article is a systematic review of the effectiveness of three practices for reducing blood culture contamination rates: venipuncture, phlebotomy teams, and prepackaged preparation/collection (prep) kits. The CDC-funded Laboratory Medicine Best Practices Initiative systematic review methods for quality improvement practices were used. Studies included as evidence were: 9 venipuncture (vs. versus intravenous catheter), 5 phlebotomy team; and 7 prep kit. All studies for venipuncture and phlebotomy teams favored these practices, with meta-analysis mean odds ratios for venipuncture of 2.69 and phlebotomy teams of 2.58. For prep kits 6 studies' effect sizes were not statistically significantly different from no effect (meta-analysis mean odds ratio 1.12). Venipuncture and the use of phlebotomy teams are effective practices for reducing blood culture contamination rates in diverse hospital settings and are recommended as evidence-based "best practices" with high overall strength of evidence and substantial effect size ratings. No recommendation is made for or against prep kits based on uncertain improvement. Copyright © 2012 The Canadian Society of Clinical Chemists. All rights reserved.

  18. The sensitivity of direct identification from positive BacT/ALERT™ (bioMérieux) blood culture bottles by matrix-assisted laser desorption ionization time-of-flight mass spectrometry is low.

    PubMed

    Szabados, F; Michels, M; Kaase, M; Gatermann, S

    2011-02-01

    Recently, matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been presented as a novel method for the direct identification of bacteria from positive blood culture bottles. The rate of the MALDI TOF MS-based identification in the present study from positive BacT/ALERT (bioMérieux, Marcy l'Etoile, France) blood culture bottles was 30%, which is far below the previously reported sensitivities using the BACTEC (Becton Dickinson, Franklin Lakes, NJ, USA) system. We also found evidence that the Biotyper algorithm did not identify a second pathogen in cases of positive BacT/ALERT blood culture bottles containing two different species. © 2010 The Authors. Journal Compilation © 2010 European Society of Clinical Microbiology and Infectious Diseases.

  19. Blood culture contamination with Enterococci and skin organisms: implications for surveillance definitions of primary bloodstream infections.

    PubMed

    Freeman, Joshua T; Chen, Luke Francis; Sexton, Daniel J; Anderson, Deverick J

    2011-06-01

    Enterococci are a common cause of bacteremia but are also common contaminants. In our institution, approximately 17% of positive blood cultures with enterococci are mixed with skin organisms. Such isolates are probable contaminants. The specificity of the current definition of primary bloodstream infection could be increased by excluding enterococci mixed with skin organisms. Copyright © 2011 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  20. [EFFECT OF RECOMBINANT ADENOVIRUS-BONE MORPHOGENETIC PROTEIN 12 TRANSFECTION ON DIFFERENTIATION OF PERIPHERAL BLOOD MESENCHYMAL STEM CELLS INTO TENDON/LIGAMENT CELLS].

    PubMed

    Fu, Weili; Chen, Gang; Tang, Xin; Li, Qi; Ll, Jian

    2015-04-01

    To research the effect of recombinant adenovirus-bone morphogenetic protein 12 (Ad-BMP-12) transfection on the differentiation of peripheral blood mesenchymal stem cells (MSCs) into tendon/ligament cells. Peripheral blood MSCs were isolated from New Zealand rabbits (3-4 months old) and cultured in vitro until passage 3. The recombinant adenoviral vector system was prepared using AdEasy system, then transfected into MSCs at passage 3 (transfected group); untransfected MSCs served as control (untransfected group). The morphological characteristics and growth of transfected cells were observed under inverted phase contrast microscope. The transfection efficiency and green fluorescent protein (GFP) expression were detected by flow cytometry (FCM) and fluorescence microscopy. After cultured for 14 days in vitro, the expressions of tendon/ligament-specific markers were determined by immunohistochemistry and real-time fluorescent quantitative PCR. GFP expression could be observed in peripheral blood MSCs at 8 hours after transfection. At 24 hours after transfection, the cells had clear morphology and grew slowly under inverted phase contrast microscope and almost all expressed GFP at the same field under fluorescence microscopy. FCM analysis showed that the transfection efficiency of the transfected group was 99.57%, while it was 2.46% in the untransfected group. The immunohistochemistry showed that the expression of collagen type I gradually increased with culture time in vitro. Real-time fluorescent quantitative PCR results showed that the mRNA expressions of the tendon/ligament-specific genes (Tenomodulin, Tenascin-C, and Decorin) in the transfected group were significantly higher than those in untransfected group (0.061+/- 0.013 vs. 0.004 +/- 0.002, t = -7.700, P=0.031; 0.029 +/- 0.008 vs. 0.003 +/- 0.001, t = -5.741, P=0.020; 0.679 +/- 0.067 vs. 0.142 +/- 0.024, t = -12.998, P=0.000). Ad-BMP-12 can significantly promote differentiation of peripheral blood MSCs into

  1. Tooth Tissue Engineering: The Importance of Blood Products as a Supplement in Tissue Culture Medium for Human Pulp Dental Stem Cells.

    PubMed

    Pisciolaro, Ricardo Luiz; Duailibi, Monica Talarico; Novo, Neil Ferreira; Juliano, Yara; Pallos, Debora; Yelick, Pamela Crotty; Vacanti, Joseph Phillip; Ferreira, Lydia Masako; Duailibi, Silvio Eduardo

    2015-11-01

    One of the goals in using cells for tissue engineering (TE) and cell therapy consists of optimizing the medium for cell culture. The present study compares three different blood product supplements for improved cell proliferation and protection against DNA damage in cultured human dental pulp stem cells for tooth TE applications. Human cells from dental pulp were first characterized as adult stem cells (ectomesenchymal mixed origin) by flow cytometry. Next, four different cell culture conditions were tested: I, supplement-free; II, supplemented with fetal bovine serum; III, allogeneic human serum; and IV, autologous human serum. Cultured cells were then characterized for cell proliferation, mineralized nodule formation, and colony-forming units (CFU) capability. After 28 days in culture, the comet assay was performed to assess possible damage in cellular DNA. Our results revealed that Protocol IV achieved higher cell proliferation than Protocol I (p = 0.0112). Protocols II and III resulted in higher cell proliferation than Protocol I, but no statistical differences were found relative to Protocol IV. The comet assay revealed less cell damage in cells cultured using Protocol IV as compared to Protocols II and III. The damage percentage observed on Protocol II was significantly higher than all other protocols. CFUs capability was highest using Protocol IV (p = 0.0018) and III, respectively, and the highest degree of mineralization was observed using Protocol IV as compared to Protocols II and III. Protocol IV resulted in significantly improved cell proliferation, and no cell damage was observed. These results demonstrate that human blood product supplements can be used as feasible supplements for culturing adult human dental stem cells.

  2. Organizational safety culture/climate and worker compliance with hazardous drug guidelines: lessons from the blood-borne pathogen experience.

    PubMed

    McDiarmid, Melissa A; Condon, Marian

    2005-07-01

    The health risks posed to health care workers (HCW) handling antineoplastic and other hazardous drugs (HDs) are well established. However, despite nearly 20 years of professional practice standards, compliance with safe handling procedures is poor. We present documentation of undercompliance with recommended safety procedures for HDs. Then, we examine a similar problem, HCW compliance with blood-borne pathogen universal precautions (UP) and its partial solution tied to the strength of a facility's safety culture. Lessons learned here may be applicable to the HD issue. It is proposed that analyzing a facility's safety culture may enlarge our understanding of the barriers contributing to HD under-compliance and suggest strategies to improve it. The Safety Culture paradigm offers many targets for intervention to enhance and promote worker compliance with safe HD handling practices thus mitigating internal exposure.

  3. Mouse preantral follicle growth in 3D co-culture system using human menstrual blood mesenchymal stem cell.

    PubMed

    Rajabi, Zahra; Yazdekhasti, Hossein; Noori Mugahi, Seyed Mohammad Hossein; Abbasi, Mehdi; Kazemnejad, Somaieh; Shirazi, Abolfazl; Majidi, Masoumeh; Zarnani, Amir-Hassan

    2018-03-01

    Follicle culture provides a condition which can help investigators to evaluate various aspects of ovarian follicle growth and development and impact of different components and supplementations as well as presumably application of follicle culture approach in fertility preservation procedures. Mesenchymal Stem Cells (MSCs), particularly those isolated from menstrual blood has the potential to be used as a tool for improvement of fertility. In the current study, a 3D co-culture system with mice preantral follicles and human Menstrual Blood Mesenchymal Stem Cells (MenSCs) using either collagen or alginate beads was designed to investigate whether this system allows better preantral follicles growth and development. Results showed that MenSCs increase the indices of follicular growth including survival rate, diameter, and antrum formation as well as the rate of in vitro maturation (IVM) in both collagen and alginates beads. Although statistically not significant, alginate was found to be superior in terms of supporting survival rate and antrum formation. Hormone assay demonstrated that the amount of secreted 17 β-estradiol and progesterone in both 3D systems increased dramatically after 12 days, with the highest levels in system employing MenSCs. Data also demonstrated that relative expression of studied genes increased for Bmp15 and Gdf9 and decreased for Mater when follicles were cultured in the presence of MenSCs. Collectively, results of the present study showed that MenSCs could improve indices of follicular growth and maturation in vitro. Further studies are needed before a clinical application of MenSCs-induced IVM is considered. Copyright © 2018 Society for Biology of Reproduction & the Institute of Animal Reproduction and Food Research of Polish Academy of Sciences in Olsztyn. All rights reserved.

  4. Superior survival of ex vivo cultured human reticulocytes following transfusion into mice.

    PubMed

    Kupzig, Sabine; Parsons, Stephen F; Curnow, Elinor; Anstee, David J; Blair, Allison

    2017-03-01

    The generation of cultured red blood cells from stem cell sources may fill an unmet clinical need for transfusion-dependent patients, particularly in countries that lack a sufficient and safe blood supply. Cultured red blood cells were generated from human CD34 + cells from adult peripheral blood or cord blood by ex vivo expansion, and a comprehensive in vivo survival comparison with standard red cell concentrates was undertaken. Significant amplification (>10 5 -fold) was achieved using CD34 + cells from both cord blood and peripheral blood, generating high yields of enucleated cultured red blood cells. Following transfusion, higher levels of cultured red cells could be detected in the murine circulation compared to standard adult red cells. The proportions of cultured blood cells from cord or peripheral blood sources remained high 24 hours post-transfusion (82±5% and 78±9%, respectively), while standard adult blood cells declined rapidly to only 49±9% by this time. In addition, the survival time of cultured blood cells in mice was longer than that of standard adult red cells. A paired comparison of cultured blood cells and standard adult red blood cells from the same donor confirmed the enhanced in vivo survival capacity of the cultured cells. The study herein represents the first demonstration that ex vivo generated cultured red blood cells survive longer than donor red cells using an in vivo model that more closely mimics clinical transfusion. Cultured red blood cells may offer advantages for transfusion-dependent patients by reducing the number of transfusions required. Copyright© Ferrata Storti Foundation.

  5. Porphyrins blood test

    MedlinePlus

    Chernecky CC, Berger BJ. Porphyrins, quantitative - blood. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . 6th ed. Philadelphia, PA: Elsevier Saunders; 2013:891-892. ...

  6. Prevalence of extended-spectrum beta-lactamase-producing Enterobacteriaceae isolated from blood cultures in Africa.

    PubMed

    Sangare, S A; Maiga, A I; Guindo, I; Maiga, A; Camara, N; Savadogo, S; Diallo, S; Bougoudogo, F; Armand-Lefevre, L; Andremont, A; Maiga, I I

    2015-09-01

    Extended-spectrum beta-lactamase (ESBL)-producing Enterobacteriaceae have been isolated from many regions of the world. Epidemiological studies are being conducted in Europe, North America, and Asia. No study has however been conducted in Africa to determine the prevalence and distribution of ESBLs on the continent. This literature review aimed at describing the prevalence of ESBL-producing Enterobacteriaceae isolated from blood cultures, as well as the ESBL genes involved at the international level. Our focus was mainly on Africa. We conducted a literature review on PubMed. Articles related to our study field and published between 1996 and 2014 were reviewed and entirely read for most of them, while we only focused on the abstracts of some other articles. Relevant articles to our study were then carefully reviewed and included in the review. The prevalence of ESBL-producing Enterobacteriaceae differs from one country to another. The results of our literature review however indicate that class A ESBLs prevail over the other types. We took into consideration articles focusing on various types of samples to assess the prevalence of ESBL-producing Enterobacteriaceae, but information on isolates from blood cultures is limited. The worldwide prevalence of ESBL-producing Enterobacteriaceae has increased over time. Evidence of ESBL-producing Enterobacteriaceae can be found in all regions of the world. Studies conducted in Africa mainly focused on the Northern and Eastern parts of the continent, while only rare studies were carried out in the rest of the continent. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  7. Evaluation of fluorescence in situ hybridisation (FISH) for the detection of fungi directly from blood cultures and cerebrospinal fluid from patients with suspected invasive mycoses.

    PubMed

    Da Silva, Roberto Moreira; Da Silva Neto, João Ricardo; Santos, Carla Silvana; Frickmann, Hagen; Poppert, Sven; Cruz, Kátia Santana; Koshikene, Daniela; De Souza, João Vicente Braga

    2015-01-31

    The aim of this study was to evaluate the diagnostic performance of in-house FISH (fluorescence in situ hybridisation) procedures for the direct identification of invasive fungal infections in blood cultures and cerebrospinal fluid (CSF) samples and to compare these FISH results with those obtained using traditional microbiological techniques and PCR targeting of the ITS1 region of the rRNA gene. In total, 112 CSF samples and 30 positive blood cultures were investigated by microscopic examination, culture, PCR-RFLP and FISH. The sensitivity of FISH for fungal infections in CSF proved to be slightly better than that of conventional microscopy (India ink) under the experimental conditions, detecting 48 (instead of 46) infections in 112 samples. The discriminatory powers of traditional microbiology, PCR-RFLP and FISH for fungal bloodstream infections were equivalent, with the detection of 14 fungal infections in 30 samples. However, the mean times to diagnosis after the detection of microbial growth by automated blood culture systems were 5 hours, 20 hours and 6 days for FISH, PCR-RFLP and traditional microbiology, respectively. The results demonstrate that FISH is a valuable tool for the identification of invasive mycoses that can be implemented in the diagnostic routine of hospital laboratories.

  8. Diagnostic accuracy of the InBiOS AMD rapid diagnostic test for the detection of Burkholderia pseudomallei antigen in grown blood culture broth.

    PubMed

    Peeters, Marjan; Chung, Panha; Lin, Hua; Mortelmans, Kristien; Phe, Chhundy; San, Chentha; Kuijpers, Laura Maria Francisca; Teav, Syna; Phe, Thong; Jacobs, Jan

    2018-06-01

    To assess the diagnostic and operational performance of the InBiOS AMD rapid diagnostic test (RDT) (Seattle, USA) for the detection of B. pseudomallei in grown blood culture broth. The InBiOS RDT is a lateral flow immunoassay in a strip format detecting B. pseudomallei capsular polysaccharide in culture fluids, marketed for research only. Broth of blood culture bottles (BacT/Alert, bioMérieux, Marcy L'Etoile, France) sampled in adult patients at the Sihanouk Hospital Center of HOPE, Phnom Penh, Cambodia, during 2010-2017 and stored at - 80 °C was tested. They included samples grown with B. pseudomallei (n = 114), samples with no growth (n = 12), and samples with growth of other pathogens (n = 139, among which Burkholderia cepacia (n = 5)). Diagnostic sensitivity and specificity were 96.5% [95% confidence interval (CI): 91.3-98.6%] and 100% [CI: 97.5-100%] respectively. Background clearance and line intensities were good and very good. The RDT's test strip, not housed in a cassette, caused difficulties in manipulation and biosafety. The centrifugation step prescribed by the procedure challenged biosafety, but processing of 19 B. pseudomallei samples without centrifugation showed similar results for line intensity and background clearance, compared to centrifugation. The InBiOS RDT showed excellent accuracy for detection of B. pseudomallei in grown blood culture broth. Provided operational adaptations such as cassette housing, it has the potential to reduce time to diagnosis of melioidosis.

  9. Typhidot M and Diazo test vis-à-vis blood culture and Widal test in the early diagnosis of typhoid fever in children in a resource poor setting.

    PubMed

    Beig, Farzana K; Ahmad, Faraz; Ekram, Mohd; Shukla, Indu

    2010-01-01

    Typhoid fever is a major public health problem. A test which is simple, reliable and can be carried out in small laboratories is the need of the hour. We prospectively evaluated typhidot M and Diazo tests vis-à-vis blood culture and Widal test in children. Patients aged 6 months to 12 years, having fever of more than four days duration with clinical suspicion of typhoid fever were enrolled. Patients in whom other diagnosis was made served as control. The tests under scrutiny were validated against blood culture and then all the four tests were evaluated among patients who presented in the first week of illness. Blood culture was positive in only 27.3% of the cases. Among these culture positive cases, typhidot M test had the highest sensitivity, specificity, PPV and NPV of 90% (95% CI = 74.4-96.5), 100% (95% CI = 90.1-100), 100% (95% CI = 87.5-100), and 92.1% (95% CI = 79.2-97.3) respectively. Diazo test ranked next with sensitivity, specificity, PPV and NPV of 86.7% (95% CI = 70.3-94.7), 85.7% (95% CI = 70.6-93.7), 83.9% (95% CI = 67.4-92.9), 88.2% (95% CI = 73.4-95.3) respectively. Among clinically suspected typhoid cases, the overall sensitivity, of blood culture, Widal, typhidot M, Diazo was 27.3% (95% CI = 19.8- 36.3), 64.6% (95% CI = 55.3-72.9), 89.1% (95% CI = 81.9-93.7), 80.9% (95% CI = 72.6-87.2) respectively. In the first week of illness, typhidot M showed the best sensitivity [86.2% (95% CI = 69.4-94.5)] followed by Diazo [79% (95% CI = 61.6-90.2)], Widal [41.4% (95% CI = 25.5-59.3)] and blood culture [31% (95% CI = 17.3-49.2)]. Both Typhidot M and Diazo are good screening tests for the diagnosis of typhoid fever. Typhidot M is superior to Diazo but the latter is more suitable to resource poor settings being economic and easy to perform.

  10. Latent cytomegalovirus infection in blood donors

    PubMed Central

    Diosi, Peter; Moldovan, Eva; Tomescu, Nicholas

    1969-01-01

    Twenty-one out of 32 apparently healthy blood donors aged 21 to 65 years yielded positive complement fixation tests with a cytomegalovirus antigen, at titres ranging from 1:8 to 1:64. Virus was present in leucocyte cultures of fresh peripheral blood of two seropositive subjects from a total of 35 donors examined. Plasma and 48-hour stored blood specimens failed to disclose virus in culture. Viruria could not be demonstrated, and there was no evidence of recent illness in the study group. These findings suggest that subclinical viraemia is not uncommon in blood donors. PMID:4311727

  11. Quantitative analysis of dengue-2 virus RNA during the extrinsic incubation period in individual Aedes aegypti.

    PubMed

    Richardson, Jason; Molina-Cruz, Alvaro; Salazar, Ma Isabel; Black, William

    2006-01-01

    Dengue virus-2 (DENV-2) RNA was quantified from the midgut and legs of individual Aedes aegypti at each of 14 days postinfectious blood meal (dpi) in a DENV-2 susceptible strain from Chetumal, Mexico. A SYBR Green I based strand-specific, quantitative real-time reverse transcription-polymerase chain reaction (RT-PCR) assay was developed. The lower detection and quantitation limits were 20 and 200 copies per reaction, respectively. Amounts of positive and negative strand viral RNA strands were correlated. Numbers of plaque-forming units (PFU) were correlated with DENV-2 RNA copy number in both C6/36 cell cultures and mosquitoes. PFU were consistently lower than RNA copy number by 2-3 log(10). Midgut levels of DENV-2 RNA peaked 8 dpi and fluctuated erratically between 6 and 9 dpi. Copies of DENV-2 RNA varied significantly among infected mosquitoes at each time point. Quantitative real-time RT-PCR is a convenient and reliable method that provides new insights into virus-vector interactions.

  12. The use of Gram stain and matrix-assisted laser desorption ionization time-of-flight mass spectrometry on positive blood culture: synergy between new and old technology.

    PubMed

    Fuglsang-Damgaard, David; Nielsen, Camilla Houlberg; Mandrup, Elisabeth; Fuursted, Kurt

    2011-10-01

    Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) is promising as an alternative to more costly and cumbersome methods for direct identifications in blood cultures. We wanted to evaluate a simplified pre-treatment method for using MALDI-TOF-MS directly on positive blood cultures using BacT/Alert blood culture system, and to test an algorithm combining the result of the initial microscopy with the result suggested by MALDI-TOF-MS. Using the recommended cut-off score of 1.7 the best results were obtained among Gram-negative rods with correct identifications in 91% of Enterobacteriaceae, 83% in aerobic/non-fermentative Gram-negative rods, whereas results were more modest among Gram-positive cocci with correct identifications in 52% of Staphylococci, 54% in Enterococci and only 20% in Streptococci. Combining the results of Gram stain with the top reports by MALDI-TOF-MS, increased the sensitivity from 91% to 93% in the score range from 1.5 to 1.7 and from 48% to 85% in the score range from 1.3 to 1.5. Thus, using this strategy and accepting a cut-off at 1.3 instead of the suggested 1.7, overall sensitivity could be increased from 88.1% to 96.3%. MALDI-TOF-MS is an efficient method for direct routine identification of bacterial isolates in blood culture, especially when combined with the result of the Gram stain. © 2011 The Authors. APMIS © 2011 APMIS.

  13. Beyond Blood Culture and Gram Stain Analysis: A Review of Molecular Techniques for the Early Detection of Bacteremia in Surgical Patients

    PubMed Central

    Kaplan, Heidi B.; Dua, Anahita; Litwin, Douglas B.; Ambrose, Catherine G.; Moore, Laura J.; Murray, COL Clinton K.; Wade, Charles E.; Holcomb, John B.

    2016-01-01

    Abstract Background: Sepsis from bacteremia occurs in 250,000 cases annually in the United States, has a mortality rate as high as 60%, and is associated with a poorer prognosis than localized infection. Because of these high figures, empiric antibiotic administration for patients with systemic inflammatory response syndrome (SIRS) and suspected infection is the second most common indication for antibiotic administration in intensive care units (ICU)s. However, overuse of empiric antibiotics contributes to the development of opportunistic infections, antibiotic resistance, and the increase in multi-drug-resistant bacterial strains. The current method of diagnosing and ruling out bacteremia is via blood culture (BC) and Gram stain (GS) analysis. Methods: Conventional and molecular methods for diagnosing bacteremia were reviewed and compared. The clinical implications, use, and current clinical trials of polymerase chain reaction (PCR)-based methods to detect bacterial pathogens in the blood stream were detailed. Results: BC/GS has several disadvantages. These include: some bacteria do not grow in culture media; others do not GS appropriately; and cultures can require up to 5 d to guide or discontinue antibiotic treatment. PCR-based methods can be potentially applied to detect rapidly, accurately, and directly microbes in human blood samples. Conclusions: Compared with the conventional BC/GS, particular advantages to molecular methods (specifically, PCR-based methods) include faster results, leading to possible improved antibiotic stewardship when bacteremia is not present. PMID:26918696

  14. Direct identification of bacteria from charcoal-containing blood culture bottles using matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry.

    PubMed

    Wüppenhorst, N; Consoir, C; Lörch, D; Schneider, C

    2012-10-01

    Several protocols for direct matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF MS) from positive blood cultures are currently used to speed up the diagnostic process of bacteraemia. Identification rates are high and results are accurate for the BACTEC™ system and for charcoal-free bottles. Only a few studies have evaluated protocols for charcoal-containing BacT/ALERT bottles reaching substantially lower identification rates. We established a new protocol for sample preparation from aerobic and anaerobic positive charcoal-containing BacT/ALERT blood culture bottles and measured the protein profiles (n = 167). Then, we integrated this protocol in the routine workflow of our laboratory (n = 212). During the establishment of our protocol, 74.3 % of bacteria were correctly identified to the species level, in 23.4 %, no result and in 2.4 %, a false identification were obtained. Reliable criteria for correct species identification were a score value ≥1.400 and a best match on rank 1-3 of the same species. Identification rates during routine workflow were 77.8 % for correct identification, 20.8 % for not identified samples and 1.4 % for discordant identification. In conclusion, our results indicate that MALDI-TOF MS is possible, even from charcoal-containing blood cultures. Reliable criteria for correct species identification are a score value ≥1.400 and a best match on rank 1-3 of a single species.

  15. Evaluation of Legionella pneumophila contamination in Italian hotel water systems by quantitative real-time PCR and culture methods.

    PubMed

    Bonetta, Sa; Bonetta, Si; Ferretti, E; Balocco, F; Carraro, E

    2010-05-01

    This study was designed to define the extent of water contamination by Legionella pneumophila of certain Italian hotels and to compare quantitative real-time PCR with the conventional culture method. Nineteen Italian hotels of different sizes were investigated. In each hotel three hot water samples (boiler, room showers, recycling) and one cold water sample (inlet) were collected. Physico-chemical parameters were also analysed. Legionella pneumophila was detected in 42% and 74% of the hotels investigated by the culture method and by real-time PCR, respectively. In 21% of samples analysed by the culture method, a concentration of >10(4) CFU l(-1) was found, and Leg. pneumophila serogroup 1 was isolated from 10.5% of the hotels. The presence of Leg. pneumophila was significantly influenced by water sample temperature, while no association with water hardness or residual-free chlorine was found. This study showed a high percentage of buildings colonized by Leg. pneumophila. Moreover, real-time PCR proved to be sensitive enough to detect lower levels of contamination than the culture method. This study indicates that the Italian hotels represent a possible source of risk for Legionnaires' disease and confirms the sensitivity of the molecular method. To our knowledge, this is the first report to demonstrate Legionella contamination in Italian hotels using real-time PCR and culture methods.

  16. Quantitative microscopy and nanoscopy of sickle red blood cells performed by wide field digital interferometry

    NASA Astrophysics Data System (ADS)

    Shaked, Natan T.; Satterwhite, Lisa L.; Telen, Marilyn J.; Truskey, George A.; Wax, Adam

    2011-03-01

    We have applied wide-field digital interferometry (WFDI) to examine the morphology and dynamics of live red blood cells (RBCs) from individuals who suffer from sickle cell anemia (SCA), a genetic disorder that affects the structure and mechanical properties of RBCs. WFDI is a noncontact, label-free optical microscopy approach that can yield quantitative thickness profiles of RBCs and measurements of their membrane fluctuations at the nanometer scale reflecting their stiffness. We find that RBCs from individuals with SCA are significantly stiffer than those from a healthy control. Moreover, we show that the technique is sensitive enough to distinguish classes of RBCs in SCA, including sickle RBCs with apparently normal morphology, compared to the stiffer crescent-shaped sickle RBCs. We expect that this approach will be useful for diagnosis of SCA and for determining efficacy of therapeutic agents.

  17. Effect of agitation and terminal subcultures on yield and speed of detection of the Oxoid Signal blood culture system versus the BACTEC radiometric system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weinstein, M.P.; Mirrett, S.; Reimer, L.G.

    1989-03-01

    In an initial evaluation, we found the Oxoid Signal blood culture system inferior to the BACTEC radiometric system for detection of some microorganisms causing septicemia. To determine whether modified processing of the Oxoid Signal blood culture system could improve its yield and speed of detecting positive cultures relative to the BACTEC radiometric system, we agitated all Oxoid bottles during the first 24 to 48 h of incubation and performed aerobic and anaerobic subcultures of all Oxoid bottles negative after 7 days of incubation. These modifications improved the overall performance of the Oxoid system, particularly with regard to the yield ofmore » streptococci, members of the family Enterobacteriaceae, and Haemophilus, Neisseria, and Acinetobacter spp. The speed of detecting positive cultures also was improved, especially within the first 24 h of incubation. However, the BACTEC system still detected more positive cultures (P less than 0.005), especially of obligate aerobes such as Pseudomonas aeruginosa (P less than 0.05) and yeasts (P less than 0.005). The BACTEC system also detected positive cultures earlier than the Oxoid system (e.g., at 24 h of incubation, 70.5% of BACTEC positive cultures detected versus 62.1% of Oxoid positive cultures detected). Further modifications of the Oxoid system which might include a revised medium, additional processing modifications, altered headspace atmosphere, or a complementary second broth medium should be considered, since the system is attractive in concept and is easy to use in the clinical laboratory.« less

  18. Simultaneous quantitation of hydroxychloroquine and its metabolites in mouse blood and tissues using LC-ESI-MS/MS: An application for pharmacokinetic studies.

    PubMed

    Chhonker, Yashpal S; Sleightholm, Richard L; Li, Jing; Oupický, David; Murry, Daryl J

    2018-01-01

    Hydroxychloroquine (HCQ) has been shown to disrupt autophagy and sensitize cancer cells to radiation and chemotherapeutic agents. However, the optimal delivery method, dose, and tumor concentrations required for these effects are not known. This is in part due to a lack of sensitive and reproducible analytical methods for HCQ quantitation in small animals. As such, we developed and validated a selective and sensitive liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) method for simultaneous quantitation of hydroxychloroquine and its metabolites in mouse blood and tissues. The chromatographic separation and detection of analytes were achieved on a reversed phase Thermo Aquasil C 18 (50×4.6mm, 3μ) column, with gradient elution using 0.2% formic acid and 0.1% formic acid in methanol as mobile phase at a flow rate of 0.5mL/min. Simple protein precipitation was utilized for extraction of analytes from the desired matrix. Analytes were separated and quantitated using MS/MS with an electrospray ionization source in positive multiple reaction monitoring (MRM) mode. The MS/MS response was linear over the concentration range from 1 to 2000ng/mL for all analytes with a correlation coefficient (R 2 ) of 0.998 or better. The within- and between-day precision (relative standard deviation, % RSD) and accuracy were within the acceptable limits per FDA guidelines. The validated method was successfully applied to a preclinical pharmacokinetic mouse study involving low volume blood and tissue samples for hydroxychloroquine and metabolites. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Development of a real-time and quantitative thrombus sensor for an extracorporeal centrifugal blood pump by near-infrared light

    PubMed Central

    Sakota, Daisuke; Fujiwara, Tatsuki; Ohuchi, Katsuhiro; Kuwana, Katsuyuki; Yamazaki, Hiroyuki; Kosaka, Ryo; Nishida, Masahiro; Mizuno, Tomohiro; Arai, Hirokuni; Maruyama, Osamu

    2017-01-01

    We developed an optical thrombus sensor for a monopivot extracorporeal centrifugal blood pump. In this study, we investigated its quantitative performance for thrombus detection in acute animal experiments of left ventricular assist using the pump on pathogen-free pigs. Optical fibers were set in the driver unit of the pump. The incident light at the near-infrared wavelength of 810 nm was aimed at the pivot bearing, and the resulting scattered light was guided to the optical fibers. The detected signal was analyzed to obtain the thrombus formation level. As a result, real-time and quantitative monitoring of the thrombus surface area on the pivot bearing was achieved with an accuracy of 3.6 ± 2.3 mm2. In addition, the sensing method using the near-infrared light was not influenced by changes in the oxygen saturation and the hematocrit. It is expected that the developed sensor will be useful for optimal anticoagulation management for long-term extracorporeal circulation therapies. PMID:29359096

  20. Development of a real-time and quantitative thrombus sensor for an extracorporeal centrifugal blood pump by near-infrared light.

    PubMed

    Sakota, Daisuke; Fujiwara, Tatsuki; Ohuchi, Katsuhiro; Kuwana, Katsuyuki; Yamazaki, Hiroyuki; Kosaka, Ryo; Nishida, Masahiro; Mizuno, Tomohiro; Arai, Hirokuni; Maruyama, Osamu

    2018-01-01

    We developed an optical thrombus sensor for a monopivot extracorporeal centrifugal blood pump. In this study, we investigated its quantitative performance for thrombus detection in acute animal experiments of left ventricular assist using the pump on pathogen-free pigs. Optical fibers were set in the driver unit of the pump. The incident light at the near-infrared wavelength of 810 nm was aimed at the pivot bearing, and the resulting scattered light was guided to the optical fibers. The detected signal was analyzed to obtain the thrombus formation level. As a result, real-time and quantitative monitoring of the thrombus surface area on the pivot bearing was achieved with an accuracy of 3.6 ± 2.3 mm 2 . In addition, the sensing method using the near-infrared light was not influenced by changes in the oxygen saturation and the hematocrit. It is expected that the developed sensor will be useful for optimal anticoagulation management for long-term extracorporeal circulation therapies.

  1. Isolation of naturally infecting Leishmania infantum from canine samples in Novy-MacNeal-Nicolle medium prepared with defibrinated blood from different animal species.

    PubMed

    Santos, Roseclea Chagas Dos; Pinho, Flaviane Alves de; Passos, Gabriela Porfírio; Larangeira, Daniela Farias; Barrouin-Melo, Stella Maria

    2018-06-15

    The most commonly used culture medium for the in vitro isolation of Leishmania spp. from canine biological samples is biphasic Novy-MacNeal-Nicolle (NNN) medium, whose solid phase is prepared using rabbit blood. Leishmania infantum parasites from natural infections are highly sensitive and demanding for growth in axenic conditions when firstly obtained from the dog's body. The objective of this study was to evaluate whether NNN medium (NNN-test) prepared with chicken blood (NNN-C), ox blood (NNN-O), horse blood (NNN-H) or sheep blood (NNN-S) was viable for the isolation of parasites from naturally infected dogs, in an endemic area for visceral leishmaniasis caused by L. infantum. Spleen aspirates from six dogs previously diagnosed as infected by parasitological methods were simultaneously inoculated in each NNN-test medium, including the conventional medium prepared with rabbit blood (NNN-R), and the cultures were examined for three weeks under optic microscopy. Spleen samples were also analyzed for parasite loads by quantitative PCR (qPCR). Cultures from three of the six dogs (50%) were positive in at least one of the NNN-test media: one sample presented the highest spleen parasite load by qPCR (1.19 × 10 4 parasites/mL) and was positive in all test media; the second sample presented parasitic isolation in the first week of culture in all inoculated media, of which the NNN-C medium had the highest mean parasite count (NNN-C = 23.5 × 10 4 /mL vs. NNN-R = 3.25 × 10 4 /mL); the third sample was positive only in the NNN-S medium besides the conventional control NNN-R. Cultures from the three remaining dogs were negative in all NNN media, including the control and test media; of those three dogs, two presented the lowest spleen parasitic loads according to qPCR. Blood from chicken, ox, horse and sheep shown to be viable for the preparation of NNN culture medium for the primary isolation of L. infantum from samples of naturally infected dogs and

  2. Imaging of blood antigen distribution on blood cells by thermal lens microscopy

    NASA Astrophysics Data System (ADS)

    Kimura, Hiroko; Sekiguchi, Kazuya; Nagao, Fumiko; Mukaida, Masahiro; Kitamori, Takehiko; Sawada, Tsuguo

    2000-05-01

    Blood group antigens on a cell were measured by a new microscopic method, i.e. thermal lens microscopy which involves spectrometry using a laser-induced thermal-lens effect. The blood group antigen was immunologically stained using antibody labeled with colloidal gold. Human leukocyte antigens (HLA) on lymphocytes and mononuclear leukocytes were observed by the thermal lens microscope, and Lewis blood group antigens on erythrocytes and polymorphonuclear leukocytes were also observed. The antigen distribution on each cell-surface was imaged using this technique. In spite of convex surface of living cells, colloidal gold was correctly quantified by adjusting the deviation of the focal point of the probe laser by the phase of the signal. In the measurement of leukocyte antigens, antigens of HLA-A, -B, -C loci on the lymphocytes were identified and quantitated by using a single cell. The image of HLA-A, -B, -C antigen distribution on a mononuclear leukocyte was obtained. In the measurement of erythrocyte antigens, a small quantity of Lewis antigens was detected on the cord erythrocytes. Localized small quantities of membrane antigens are better quantitated without extraction or cytolysis. Our thermal lens microscope is a powerful and highly sensitive analytical tool for detecting and quantitating localized antigens in single cells and/or cell-surface-associated molecules.

  3. Validated semiquantitative/quantitative screening of 51 drugs in whole blood as silylated derivatives by gas chromatography-selected ion monitoring mass spectrometry and gas chromatography electron capture detection.

    PubMed

    Gunnar, Teemu; Mykkänen, Sirpa; Ariniemi, Kari; Lillsunde, Pirjo

    2004-07-05

    A comprehensively validated procedure is presented for simultaneous semiquantitative/quantitative screening of 51 drugs of abuse or drugs potentially hazardous for traffic safety in serum, plasma or whole blood. Benzodiazepines (12), cannabinoids (3), opioids (8), cocaine, antidepressants (13), antipsychotics (5) and antiepileptics (2) as well as zolpidem, zaleplon, zopiclone, meprobamate, carisoprodol, tizanidine and orphenadrine and internal standard flurazepam, were isolated by high-yield liquid-liquid extraction (LLE). The dried extracts were derivatized by two-step silylation and analyzed by the combination of two different gas chromatographic (GC) separations with both electron capture detection (ECD) and mass spectrometry (MS) operating in a selected ion-monitoring (SIM) mode. Quantitative or semiquantitative results were obtained for each substance based on four-point calibration. In the validation tests, accuracy, reproducibility, linearity, limit of detection (LOD) and limit of quantitation (LOQ), selectivity, as well as extraction efficiency and stability of standard stock solutions were tested, and derivatization was optimized in detail. Intra- and inter-day precisions were within 2.5-21.8 and 6.0-22.5%, and square of correlation coefficients of linearity ranged from 0.9896 to 0.9999. The limit of quantitation (LOQ) varied from 2 to 2000 ng/ml due to a variety of the relevant concentrations of the analyzed substances in blood. The method is feasible for highly sensitive, reliable and possibly routinely performed clinical and forensic toxicological analyses.

  4. An in vivo quantitative Raman-pH sensor of arterial blood based on laser trapping of erythrocytes.

    PubMed

    Lin, Manman; Xu, Bin; Yao, Huilu; Shen, Aiguo; Hu, Jiming

    2016-05-10

    We report on a continuous and non-invasive approach in vivo to monitor arterial blood pH based on the laser trapping and Raman detection of single live erythrocytes. A home-built confocal laser tweezers Raman system (LTRS) is applied to trace the live erythrocytes at different pH values of the extracellular environment to record their corresponding Raman changes in vitro and in vivo. The analysis results in vitro show that when the extracellular environment pH changes from 6.5 to 9.0, the Raman intensity ratio (R1603, 1616 = I1603/I1616) of single erythrocytes decrease regularly; what is more, there is a good linear relationship between these two variables, and the linearity is 0.985, which is also verified successfully via in vivo Raman measurements. These results demonstrate that the Raman signal of single live erythrocytes is possible as a marker of the extracellular pH value. This in vivo and quantitative Raman-pH sensor of arterial blood will be an important candidate for monitoring the acid-base status during the treatment of ill patients and in some major surgeries because of its continuous and non-invasive characters.

  5. [A case of sphenoid sinusitis which could be diagnosed by orbital computed tomography after detected Strepotococcus pneumoniae from blood culture].

    PubMed

    Kimura, Takuma; Aoki, Makoto; Aoki, Yasuko; Tonhyo, Chong

    2005-03-01

    We report a case of sphenoid sinusitis which could be diagnosed by orbital CT after detecting Strepotococcus pneumoniae from blood culture. A previously healthy 47 year-old Japanese male was admitted to our hospital with severe left-sided headache of 2 days duration. From 9 days before hospitalization (1st day), the patient complained of cough and sputum. On physical examination, his neck was supple and his temperature was 38.3 degrees C. The rest of the examination was normal. A chest radiograph, sinus radiograph, and head computed tomographic (CT) scan without contrast material disclosed no abnormalities. Lumbar puncture was done and cerebrospinal fluid was clear and cell counts and the levels of glucose and protein were normal. The peripheral white blood cell count was 14,400/fl, and the C-reactive protein level was 9.6 mg/dl. After blood, urine, pharyngeal mucus and cerebrospinal fluid cultures were obtained, empirical antibiotic therapy with 2 gms of piperacillin twice daily was begun. He complained sever left-sided retro-orbital headahe on the next day too. The lumbar puncture and head CT scan with contrast material was done again but gave no diagnostic clues. The examinations by the otolaryngologist, ophthalmologist and dentist found no abnormal findings. On the 3rd hospitalized day, Strepotococcus pneumoniae was detected from the blood culture taken on the 1st hospitalized day. A CT scan focused on orbita was done and revealed a low density area of the left sphenoid sinus. The dose of piperacillin was increased to 4 gms twice daily and continued for 24 days. The patient's headache improved and piperacillin was changed to oral levofloxacin 100 mg, three times daily on the 26th day. The medication was stopped on the 73th day. Isolated sphenoid sinusitis is rare, but crtitical complications such as cranial nerve involvement, brain abscess, and bacterial meningitis may happen. It is necessary to also think of sphenoid sinusitis in practices of patients with

  6. Pleural fluid culture

    MedlinePlus

    ... Risks of thoracentesis are: Collapsed lung ( pneumothorax ) Excessive loss of blood Fluid reaccumulation Infection Pulmonary edema Respiratory distress Serious complications are uncommon Alternative Names Culture - pleural fluid Images Pleural culture References Chernecky CC, ...

  7. [Evaluation of PNA-FISH method for direct identification of Candida species in blood culture samples and its potential impact on guidance of antifungal therapy].

    PubMed

    Doğan, Özlem; İnkaya, Ahmet Çağkan; Gülmez, Dolunay; Uzun, Ömrüm; Akova, Murat; Arıkan Akdağlı, Sevtap

    2016-10-01

    Early antifungal therapy has a major influence on survival in candidemia. Rapid identification of the species has importance for the treatment, prediction of the species-specific primary resistance and variable antifungal susceptibility. Recently, molecular-based methods attempt to reduce the time between the positive signal of a blood culture and identification of the fungus. PNA-FISH (Peptide nucleic acid fluorescence in situ hybridization) assay distinguishes a number of frequently isolated Candida species in groups following the growth in blood culture. The aim of this study was to investigate the correlation of the species identified by PNA-FISH with conventional identification methods in yeast positive blood cultures and its influence on the selection of antifungal therapy. Specimens of adult patients diagnosed as yeast with Gram stain in signal-positive blood cultures between August to December 2013, were included in the study. The strains were concomitantly cultivated by subculturing from the blood culture bottles onto solid media and identified by conventional methods (germ tube test, ID32C and morphology on cornmeal Tween 80 agar). Rapid species identification was performed by Yeast Traffic Light PNA-FISH, which generates green flourescence for Candida albicans and Candida parapsilosis, yellow for Candida tropicalis, and red for Candida krusei and Candida glabrata. C.tropicalis was identified as a single species whereas the others were identified in pairs. The time points when the yeast positive blood culture bottle was received by the mycology laboratory and reporting of the species identification results by PNA-FISH and the conventional methods were recorded. Seven C.albicans, six C.glabrata, three C.parapsilosis, one C.tropicalis, one C.krusei, one Cryptococcus neoformans, one Saprochaete capitata (Blastoschizomyces capitatus), one C.albicans and Candida dubliniensis, one C.krusei and C.dubliniensis, and one C.glabrata and C.parapsilosis were

  8. Glycosyltransferases as marker genes for the quantitative polymerase chain reaction-based detection of circulating tumour cells from blood samples of patients with breast cancer undergoing adjuvant therapy.

    PubMed

    Kölbl, Alexandra C; Hiller, Roman A; Ilmer, Mathias; Liesche, Friederike; Heublein, Sabine; Schröder, Lennard; Hutter, Stefan; Friese, Klaus; Jeschke, Udo; Andergassen, Ulrich

    2015-08-01

    Altered glycosylation is a predominant feature of tumour cells; it serves for cell adhesion and detachment, respectively, and facilitates the immune escape of these cells. Therefore changes in the expression of glycosyltransferase genes could help to identify circulating tumour cells (CTCs) in the blood samples of cancer patients using a quantitative polymerase chain reaction (PCR) approach. Blood samples of healthy donors were inoculated with certain numbers of established breast cancer cell line cells, thus creating a model system. These samples were analysed by quantitative PCR for the expression of six different glycosyltransferase genes. The three genes with the best results in the model system were consecutively applied to samples from adjuvant breast cancer patients and of healthy donors. FUT3 and GALNT6 showed the highest increase in relative expression, while GALNT6 and ST3GAL3 were the first to reach statistically significant different ∆CT-values comparing the sample with and without addition of tumour cells. These three genes were applied to patient samples, but did not show any significant results that may suggest the presence of CTCs in the blood. Although the relative expression of some of the glycosyltransferase genes exhibited reasonable results in the model system, their application to breast cancer patient samples will have to be further improved, e.g. by co-analysis of patient blood samples by gold-standard methods.

  9. CHROMagar Orientation Medium Reduces Urine Culture Workload

    PubMed Central

    Manickam, Kanchana; Karlowsky, James A.; Adam, Heather; Lagacé-Wiens, Philippe R. S.; Rendina, Assunta; Pang, Paulette; Murray, Brenda-Lee

    2013-01-01

    Microbiology laboratories continually strive to streamline and improve their urine culture algorithms because of the high volumes of urine specimens they receive and the modest numbers of those specimens that are ultimately considered clinically significant. In the current study, we quantitatively measured the impact of the introduction of CHROMagar Orientation (CO) medium into routine use in two hospital laboratories and compared it to conventional culture on blood and MacConkey agars. Based on data extracted from our Laboratory Information System from 2006 to 2011, the use of CO medium resulted in a 28% reduction in workload for additional procedures such as Gram stains, subcultures, identification panels, agglutination tests, and biochemical tests. The average number of workload units (one workload unit equals 1 min of hands-on labor) per urine specimen was significantly reduced (P < 0.0001; 95% confidence interval [CI], 0.5326 to 1.047) from 2.67 in 2006 (preimplementation of CO medium) to 1.88 in 2011 (postimplementation of CO medium). We conclude that the use of CO medium streamlined the urine culture process and increased bench throughput by reducing both workload and turnaround time in our laboratories. PMID:23363839

  10. MALDI-TOF mass spectrometry following short incubation on a solid medium is a valuable tool for rapid pathogen identification from positive blood cultures.

    PubMed

    Kohlmann, Rebekka; Hoffmann, Alexander; Geis, Gabriele; Gatermann, Sören

    2015-01-01

    Rapid identification of the causative microorganism is a key element in appropriate antimicrobial therapy of bloodstream infections. Whereas traditional analysis of positive blood cultures requires subculture over at least 16-24h prior to pathogen identification by, e.g. matrix-assisted laser-desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS), sample preparation procedures enabling direct MALDI-TOF MS, i.e. without preceding subculture, are associated with additional effort and costs. Hence, we integrated an alternative MALDI-TOF MS approach in diagnostic routine using a short incubation on a solid medium. Positive blood cultures were routinely plated on chocolate agar plates and incubated for 4h (37 °C, 5% CO2). Subsequently, MALDI-TOF MS using a Microflex LT instrument (Bruker Daltonics) and direct smear method was performed once per sample. For successful identification of bacteria at species level, score cut-off values were used as proposed by the manufacturer (≥ 2.0) and in a modified form (≥ 1.5 for MALDI-TOF MS results referring to Gram-positive cocci and ≥ 1.7 for MALDI-TOF MS results referring to bacteria other than Gram-positive cocci). Further data analysis also included an assessment of the clinical impact of the MALDI-TOF MS result. Applying the modified score cut-off values, our approach led to an overall correct species identification in 69.5% with misidentification in 3.4% (original cut-offs: 49.2% and 1.8%, respectively); for Gram-positive cocci, correct identification in 68.4% (100% for Staphylococcus aureus and enterococci, 80% for beta-hemolytic streptococci), for Gram-negative bacteria, correct identification in 97.6%. In polymicrobial blood cultures, in 72.7% one of the pathogens was correctly identified. Results were not reliable for Gram-positive rods and yeasts. The approach was easy to implement in diagnostic routine. In cases with available clinical data and successful pathogen identification, in 51.1% our

  11. Proliferation of Peripheral Blood Lymphocytes and Mesenchymal Stromal Cells Derived from Wharton's Jelly in Mixed and Membrane-Separated Cultures.

    PubMed

    Poltavtsev, A M; Poltavtseva, R A; Yushina, M N; Pavlovich, S V; Svirshchevskaya, E V

    2017-08-01

    We studied the effect of mesenchymal stromal cells on proliferation of CFSE-stained T cells in mixed and membrane-separated (Transwell) cultures and in 3D culture of mesenchymal stromal cells from Wharton's jelly. The interaction of mesenchymal stromal cells with mitogen-activated peripheral blood lymphocytes from an allogeneic donor was followed by suppression of T-cell proliferation in a wide range of cell proportions. Culturing in the Transwell system showed the absence of suppression assessed by the fraction of proliferating cells and by the cell cycle analysis. In 3D cultures, contact interaction of mesenchymal stromal cells and lymphocytes was demonstrated that led to accumulation of G2/M phase lymphocytes and G0/G1 phase mesenchymal stromal cells. The suppressive effect of mesenchymal stromal cells from Wharton's jelly is mediated by two mechanisms. The effects are realized within 6 days, which suggests that the therapeutic effects of mesenchymal stromal cells persist until their complete elimination from the body.

  12. Evaluation of the LightCycler Staphylococcus MGRADE Kits on Positive Blood Cultures That Contained Gram-Positive Cocci in Clusters

    PubMed Central

    Shrestha, Nabin K.; Tuohy, Marion J.; Padmanabhan, Ravindran A.; Hall, Gerri S.; Procop, Gary W.

    2005-01-01

    We evaluated the Roche LightCycler Staphylococcus MGRADE kits to differentiate between Staphylococcus aureus and coagulase-negative staphylococci in blood cultures growing clusters of gram-positive cocci. Testing 100 bottles (36 containing S. aureus), the assay was 100% sensitive and 98.44% specific for S. aureus and 100% sensitive and specific for coagulase-negative staphylococci. PMID:16333115

  13. A model of blood-ammonia homeostasis based on a quantitative analysis of nitrogen metabolism in the multiple organs involved in the production, catabolism, and excretion of ammonia in humans.

    PubMed

    Levitt, David G; Levitt, Michael D

    2018-01-01

    Increased blood ammonia (NH 3 ) is an important causative factor in hepatic encephalopathy, and clinical treatment of hepatic encephalopathy is focused on lowering NH 3 . Ammonia is a central element in intraorgan nitrogen (N) transport, and modeling the factors that determine blood-NH 3 concentration is complicated by the need to account for a variety of reactions carried out in multiple organs. This review presents a detailed quantitative analysis of the major factors determining blood-NH 3 homeostasis - the N metabolism of urea, NH 3 , and amino acids by the liver, gastrointestinal system, muscle, kidney, and brain - with the ultimate goal of creating a model that allows for prediction of blood-NH 3 concentration. Although enormous amounts of NH 3 are produced during normal liver amino-acid metabolism, this NH 3 is completely captured by the urea cycle and does not contribute to blood NH 3 . While some systemic NH 3 derives from renal and muscle metabolism, the primary site of blood-NH 3 production is the gastrointestinal tract, as evidenced by portal vein-NH 3 concentrations that are about three times that of systemic blood. Three mechanisms, in order of quantitative importance, release NH 3 in the gut: 1) hydrolysis of urea by bacterial urease, 2) bacterial protein deamination, and 3) intestinal mucosal glutamine metabolism. Although the colon is conventionally assumed to be the major site of gut-NH 3 production, evidence is reviewed that indicates that the stomach (via Helicobacter pylori metabolism) and small intestine and may be of greater importance. In healthy subjects, most of this gut NH 3 is removed by the liver before reaching the systemic circulation. Using a quantitative model, loss of this "first-pass metabolism" due to portal collateral circulation can account for the hyperammonemia observed in chronic liver disease, and there is usually no need to implicate hepatocyte malfunction. In contrast, in acute hepatic necrosis, hyperammonemia results

  14. Contribution of sonicate-fluid cultures and broad-range PCR to microbiological diagnosis in vascular graft infections.

    PubMed

    Kokosar Ulcar, Barbara; Lakic, Nikola; Jeverica, Samo; Pecavar, Blaz; Logar, Mateja; Cerar, Tjasa Kisek; Lejko-Zupanc, Tatjana

    2018-06-01

    Vascular graft infections (VGI) are associated with considerable morbidity and mortality, and antimicrobial treatment is an important adjunct to surgical treatment. While microbial aetiology of VGI is often difficult to determine, other techniques such as sonication of implanted material may be used to enhance the recovery of biofilm-associated organisms. We performed a retrospective analysis of 22 consecutive patients treated for VGI at University Medical Centre Ljubljana from May 2011 through January 2015. Explanted vascular grafts were flooded with sterile Ringer solution, sonicated for 1 min at a frequency of 40 kHz and inoculated on solid and liquid culture media. Aerobic and anaerobic cultures were performed, incubated for 14 days and any significant bacterial growth was quantitatively evaluated. Additionally, broad-range PCR from sonicate fluid was performed. Microbiological results were compared with the results of preoperatively taken blood cultures and the results of intraoperative tissue cultures (material from peri-graft collection). Identification of the causative organism (irrespective of the method) was achieved in 95.8%. Preoperative blood cultures were positive in 35.3%, intraoperative tissue cultures in 31.8%, sonicate fluid culture in 79.2%, while broad-range PCR from sonicate fluid was positive in 66.7%. In 37.5% the pathogen detected in sonicate fluid culture or broad-range PCR was the only positive microbiological result. Sonicate fluid culture and broad-range PCR from explanted vascular grafts may contribute to optimization of antimicrobial treatment. Optimal timing of antibiotic therapy before explantation should be further assessed to improve diagnostic yield.

  15. Modelling the endothelial blood-CNS barriers: a method for the production of robust in vitro models of the rat blood-brain barrier and blood-spinal cord barrier

    PubMed Central

    2013-01-01

    Background Modelling the blood-CNS barriers of the brain and spinal cord in vitro continues to provide a considerable challenge for research studying the passage of large and small molecules in and out of the central nervous system, both within the context of basic biology and for pharmaceutical drug discovery. Although there has been considerable success over the previous two decades in establishing useful in vitro primary endothelial cell cultures from the blood-CNS barriers, no model fully mimics the high electrical resistance, low paracellular permeability and selective influx/efflux characteristics of the in vivo situation. Furthermore, such primary-derived cultures are typically labour-intensive and generate low yields of cells, limiting scope for experimental work. We thus aimed to establish protocols for the high yield isolation and culture of endothelial cells from both rat brain and spinal cord. Our aim was to optimise in vitro conditions for inducing phenotypic characteristics in these cells that were reminiscent of the in vivo situation, such that they developed into tight endothelial barriers suitable for performing investigative biology and permeability studies. Methods Brain and spinal cord tissue was taken from the same rats and used to specifically isolate endothelial cells to reconstitute as in vitro blood-CNS barrier models. Isolated endothelial cells were cultured to expand the cellular yield and then passaged onto cell culture inserts for further investigation. Cell culture conditions were optimised using commercially available reagents and the resulting barrier-forming endothelial monolayers were characterised by functional permeability experiments and in vitro phenotyping by immunocytochemistry and western blotting. Results Using a combination of modified handling techniques and cell culture conditions, we have established and optimised a protocol for the in vitro culture of brain and, for the first time in rat, spinal cord endothelial cells

  16. Modelling the endothelial blood-CNS barriers: a method for the production of robust in vitro models of the rat blood-brain barrier and blood-spinal cord barrier.

    PubMed

    Watson, P Marc D; Paterson, Judy C; Thom, George; Ginman, Ulrika; Lundquist, Stefan; Webster, Carl I

    2013-06-18

    Modelling the blood-CNS barriers of the brain and spinal cord in vitro continues to provide a considerable challenge for research studying the passage of large and small molecules in and out of the central nervous system, both within the context of basic biology and for pharmaceutical drug discovery. Although there has been considerable success over the previous two decades in establishing useful in vitro primary endothelial cell cultures from the blood-CNS barriers, no model fully mimics the high electrical resistance, low paracellular permeability and selective influx/efflux characteristics of the in vivo situation. Furthermore, such primary-derived cultures are typically labour-intensive and generate low yields of cells, limiting scope for experimental work. We thus aimed to establish protocols for the high yield isolation and culture of endothelial cells from both rat brain and spinal cord. Our aim was to optimise in vitro conditions for inducing phenotypic characteristics in these cells that were reminiscent of the in vivo situation, such that they developed into tight endothelial barriers suitable for performing investigative biology and permeability studies. Brain and spinal cord tissue was taken from the same rats and used to specifically isolate endothelial cells to reconstitute as in vitro blood-CNS barrier models. Isolated endothelial cells were cultured to expand the cellular yield and then passaged onto cell culture inserts for further investigation. Cell culture conditions were optimised using commercially available reagents and the resulting barrier-forming endothelial monolayers were characterised by functional permeability experiments and in vitro phenotyping by immunocytochemistry and western blotting. Using a combination of modified handling techniques and cell culture conditions, we have established and optimised a protocol for the in vitro culture of brain and, for the first time in rat, spinal cord endothelial cells. High yields of both CNS

  17. Reproducibility and Accuracy of Quantitative Myocardial Blood Flow Using 82Rb-PET: Comparison with 13N-Ammonia

    PubMed Central

    Fakhri, Georges El

    2011-01-01

    82Rb cardiac PET allows the assessment of myocardial perfusion using a column generator in clinics that lack a cyclotron. We and others have previously shown that quantitation of myocardial blood flow (MBF) and coronary flow reserve (CFR) is feasible using dynamic 82Rb PET and factor and compartment analyses. The aim of the present work was to determine the intra- and inter-observer variability of MBF estimation using 82Rb PET as well as the reproducibility of our generalized factor + compartment analyses methodology to estimate MBF and assess its accuracy by comparing, in the same subjects, 82Rb estimates of MBF to those obtained using 13N-ammonia. Methods Twenty-two subjects were included in the reproducibility and twenty subjects in the validation study. Patients were injected with 60±5mCi of 82Rb and imaged dynamically for 6 minutes at rest and during dipyridamole stress Left and right ventricular (LV+RV) time-activity curves were estimated by GFADS and used as input to a 2-compartment kinetic analysis that estimates parametric maps of myocardial tissue extraction (K1) and egress (k2), as well as LV+RV contributions (fv,rv). Results Our results show excellent reproducibility of the quantitative dynamic approach itself with coefficients of repeatability of 1.7% for estimation of MBF at rest, 1.4% for MBF at peak stress and 2.8% for CFR estimation. The inter-observer reproducibility between the four observers that participated in this study was also very good with correlation coefficients greater than 0.87 between any two given observers when estimating coronary flow reserve. The reproducibility of MBF in repeated 82Rb studies was good at rest and excellent at peak stress (r2=0.835). Furthermore, the slope of the correlation line was very close to 1 when estimating stress MBF and CFR in repeated 82Rb studies. The correlation between myocardial flow estimates obtained at rest and during peak stress in 82Rb and 13N-ammonia studies was very good at rest (r2

  18. Multimarker Quantitative Real-Time PCR Detection of Circulating Melanoma Cells in Peripheral Blood: Relation to Disease Stage in Melanoma Patients

    PubMed Central

    Koyanagi, Kazuo; Kuo, Christine; Nakagawa, Taku; Mori, Takuji; Ueno, Hideaki; Lorico, Arnulfo R.; Wang, He-Jing; Hseuh, Eddie; O’Day, Steven J.; Hoon, Dave S.B.

    2010-01-01

    Background Detection of melanoma cells in circulation may be important in assessing tumor progression. The objective of this study was to develop a specific, reliable, multimarker quantitative real-time reverse transcription-PCR (qRT) assay for detecting melanoma cells in patients’ blood. Methods We developed qRT assays for the mRNA of four melanoma-associated markers: MART-1, GalNAc-T, PAX-3, and MAGE-A3. In optimization studies, we tested 17 melanoma cell lines and 49 peripheral blood leukocyte (PBL) samples from volunteers. We performed RNA and melanoma cell dilution studies to assess the detection limits and imprecision of the assays. We measured the mRNAs in blood specimens from 94 melanoma patients [American Joint Committee on Cancer (AJCC) stage I, n = 20; II, n = 20; III, n = 32; IV, n = 22]. Results All markers were frequently detected in melanoma cell lines, whereas none of the markers was detected in PBLs from volunteers. The qRT assay could detect 1 melanoma cell in 107 PBLs in the melanoma cell-dilution studies. Markers were detected in 15%, 30%, 75%, and 86% of melanoma patients with AJCC stage I, II, III, and IV disease, respectively. The number of positive markers and AJCC stage were significantly correlated (Spearman correlation coefficient = 0.58; P <0.0001). Conclusions Multimarker qRT can detect circulating melanoma cells in blood. Measurement of the studied molecular markers in blood may be useful in detection of metastasis and monitoring treatment response of melanoma patients. PMID:15817820

  19. Application of Real-Time Fluorescent PCR for Quantitative Assessment of Neospora caninum Infections in Organotypic Slice Cultures of Rat Central Nervous System Tissue

    PubMed Central

    Müller, Norbert; Vonlaufen, Nathalie; Gianinazzi, Christian; Leib, Stephen L.; Hemphill, Andrew

    2002-01-01

    The previously described Nc5-specific PCR test for the diagnosis of Neospora caninum infections was used to develop a quantitative PCR assay which allows the determination of infection intensities within different experimental and diagnostic sample groups. The quantitative PCR was performed by using a dual fluorescent hybridization probe system and the LightCycler Instrument for online detection of amplified DNA. This assay was successfully applied for demonstrating the parasite proliferation kinetics in organotypic slice cultures of rat brain which were infected in vitro with N. caninum tachyzoites. This PCR-based method of parasite quantitation with organotypic brain tissue samples can be regarded as a novel ex vivo approach for exploring different aspects of cerebral N. caninum infection. PMID:11773124

  20. The Clinical Urine Culture: Enhanced Techniques Improve Detection of Clinically Relevant Microorganisms

    PubMed Central

    Price, Travis K.; Dune, Tanaka; Hilt, Evann E.; Thomas-White, Krystal J.; Kliethermes, Stephanie; Brincat, Cynthia; Brubaker, Linda; Wolfe, Alan J.

    2016-01-01

    Enhanced quantitative urine culture (EQUC) detects live microorganisms in the vast majority of urine specimens reported as “no growth” by the standard urine culture protocol. Here, we evaluated an expanded set of EQUC conditions (expanded-spectrum EQUC) to identify an optimal version that provides a more complete description of uropathogens in women experiencing urinary tract infection (UTI)-like symptoms. One hundred fifty adult urogynecology patient-participants were characterized using a self-completed validated UTI symptom assessment (UTISA) questionnaire and asked “Do you feel you have a UTI?” Women responding negatively were recruited into the no-UTI cohort, while women responding affirmatively were recruited into the UTI cohort; the latter cohort was reassessed with the UTISA questionnaire 3 to 7 days later. Baseline catheterized urine samples were plated using both standard urine culture and expanded-spectrum EQUC protocols: standard urine culture inoculated at 1 μl onto 2 agars incubated aerobically; expanded-spectrum EQUC inoculated at three different volumes of urine onto 7 combinations of agars and environments. Compared to expanded-spectrum EQUC, standard urine culture missed 67% of uropathogens overall and 50% in participants with severe urinary symptoms. Thirty-six percent of participants with missed uropathogens reported no symptom resolution after treatment by standard urine culture results. Optimal detection of uropathogens could be achieved using the following: 100 μl of urine plated onto blood (blood agar plate [BAP]), colistin-nalidixic acid (CNA), and MacConkey agars in 5% CO2 for 48 h. This streamlined EQUC protocol achieved 84% uropathogen detection relative to 33% detection by standard urine culture. The streamlined EQUC protocol improves detection of uropathogens that are likely relevant for symptomatic women, giving clinicians the opportunity to receive additional information not currently reported using standard urine culture

  1. Evaluation of the Accelerate Pheno System for Fast Identification and Antimicrobial Susceptibility Testing from Positive Blood Cultures in Bloodstream Infections Caused by Gram-Negative Pathogens.

    PubMed

    Marschal, Matthias; Bachmaier, Johanna; Autenrieth, Ingo; Oberhettinger, Philipp; Willmann, Matthias; Peter, Silke

    2017-07-01

    Bloodstream infections (BSI) are an important cause of morbidity and mortality. Increasing rates of antimicrobial-resistant pathogens limit treatment options, prompting an empirical use of broad-range antibiotics. Fast and reliable diagnostic tools are needed to provide adequate therapy in a timely manner and to enable a de-escalation of treatment. The Accelerate Pheno system (Accelerate Diagnostics, USA) is a fully automated test system that performs both identification and antimicrobial susceptibility testing (AST) directly from positive blood cultures within approximately 7 h. In total, 115 episodes of BSI with Gram-negative bacteria were included in our study and compared to conventional culture-based methods. The Accelerate Pheno system correctly identified 88.7% (102 of 115) of all BSI episodes and 97.1% (102 of 105) of isolates that are covered by the system's identification panel. The Accelerate Pheno system generated an AST result for 91.3% (95 of 104) samples in which the Accelerate Pheno system identified a Gram-negative pathogen. The overall category agreement between the Accelerate Pheno system and culture-based AST was 96.4%, the rates for minor discrepancies 1.4%, major discrepancies 2.3%, and very major discrepancies 1.0%. Of note, ceftriaxone, piperacillin-tazobactam, and carbapenem resistance was correctly detected in blood culture specimens with extended-spectrum beta-lactamase-producing Escherichia coli ( n = 7) and multidrug-resistant Pseudomonas aeruginosa ( n = 3) strains. The utilization of the Accelerate Pheno system reduced the time to result for identification by 27.49 h ( P < 0.0001) and for AST by 40.39 h ( P < 0.0001) compared to culture-based methods in our laboratory setting. In conclusion, the Accelerate Pheno system provided fast, reliable results while significantly improving turnaround time in blood culture diagnostics of Gram-negative BSI. Copyright © 2017 American Society for Microbiology.

  2. Visualisation and quantitative analysis of the rodent malaria liver stage by real time imaging.

    PubMed

    Ploemen, Ivo H J; Prudêncio, Miguel; Douradinha, Bruno G; Ramesar, Jai; Fonager, Jannik; van Gemert, Geert-Jan; Luty, Adrian J F; Hermsen, Cornelus C; Sauerwein, Robert W; Baptista, Fernanda G; Mota, Maria M; Waters, Andrew P; Que, Ivo; Lowik, Clemens W G M; Khan, Shahid M; Janse, Chris J; Franke-Fayard, Blandine M D

    2009-11-18

    The quantitative analysis of Plasmodium development in the liver in laboratory animals in cultured cells is hampered by low parasite infection rates and the complicated methods required to monitor intracellular development. As a consequence, this important phase of the parasite's life cycle has been poorly studied compared to blood stages, for example in screening anti-malarial drugs. Here we report the use of a transgenic P. berghei parasite, PbGFP-Luc(con), expressing the bioluminescent reporter protein luciferase to visualize and quantify parasite development in liver cells both in culture and in live mice using real-time luminescence imaging. The reporter-parasite based quantification in cultured hepatocytes by real-time imaging or using a microplate reader correlates very well with established quantitative RT-PCR methods. For the first time the liver stage of Plasmodium is visualized in whole bodies of live mice and we were able to discriminate as few as 1-5 infected hepatocytes per liver in mice using 2D-imaging and to identify individual infected hepatocytes by 3D-imaging. The analysis of liver infections by whole body imaging shows a good correlation with quantitative RT-PCR analysis of extracted livers. The luminescence-based analysis of the effects of various drugs on in vitro hepatocyte infection shows that this method can effectively be used for in vitro screening of compounds targeting Plasmodium liver stages. Furthermore, by analysing the effect of primaquine and tafenoquine in vivo we demonstrate the applicability of real time imaging to assess parasite drug sensitivity in the liver. The simplicity and speed of quantitative analysis of liver-stage development by real-time imaging compared to the PCR methodologies, as well as the possibility to analyse liver development in live mice without surgery, opens up new possibilities for research on Plasmodium liver infections and for validating the effect of drugs and vaccines on the liver stage of

  3. Visualisation and Quantitative Analysis of the Rodent Malaria Liver Stage by Real Time Imaging

    PubMed Central

    Douradinha, Bruno G.; Ramesar, Jai; Fonager, Jannik; van Gemert, Geert-Jan; Luty, Adrian J. F.; Hermsen, Cornelus C.; Sauerwein, Robert W.; Baptista, Fernanda G.; Mota, Maria M.; Waters, Andrew P.; Que, Ivo; Lowik, Clemens W. G. M.; Khan, Shahid M.; Janse, Chris J.; Franke-Fayard, Blandine M. D.

    2009-01-01

    The quantitative analysis of Plasmodium development in the liver in laboratory animals in cultured cells is hampered by low parasite infection rates and the complicated methods required to monitor intracellular development. As a consequence, this important phase of the parasite's life cycle has been poorly studied compared to blood stages, for example in screening anti-malarial drugs. Here we report the use of a transgenic P. berghei parasite, PbGFP-Luccon, expressing the bioluminescent reporter protein luciferase to visualize and quantify parasite development in liver cells both in culture and in live mice using real-time luminescence imaging. The reporter-parasite based quantification in cultured hepatocytes by real-time imaging or using a microplate reader correlates very well with established quantitative RT-PCR methods. For the first time the liver stage of Plasmodium is visualized in whole bodies of live mice and we were able to discriminate as few as 1–5 infected hepatocytes per liver in mice using 2D-imaging and to identify individual infected hepatocytes by 3D-imaging. The analysis of liver infections by whole body imaging shows a good correlation with quantitative RT-PCR analysis of extracted livers. The luminescence-based analysis of the effects of various drugs on in vitro hepatocyte infection shows that this method can effectively be used for in vitro screening of compounds targeting Plasmodium liver stages. Furthermore, by analysing the effect of primaquine and tafenoquine in vivo we demonstrate the applicability of real time imaging to assess parasite drug sensitivity in the liver. The simplicity and speed of quantitative analysis of liver-stage development by real-time imaging compared to the PCR methodologies, as well as the possibility to analyse liver development in live mice without surgery, opens up new possibilities for research on Plasmodium liver infections and for validating the effect of drugs and vaccines on the liver stage of

  4. Viral drug sensitivity testing using quantitative PCR: effect of tyrosine kinase inhibitors on polyomavirus BK replication.

    PubMed

    Randhawa, Parmjeet S; Farasati, Noush A; Huang, Yuchen; Mapara, Markus Y; Shapiro, Ron

    2010-12-01

    Our objective was to determine whether quantitative polymerase chain reaction (PCR) can be used to measure the effect of tyrosine kinase (TK) inhibition on polyomavirus BK (BKV) replication. The BKV was grown in a cell culture system. The rate of viral replication in the presence or absence of the drug being tested was assessed by amplifying the viral genome using primers directed against the viral capsid 1 protein. Dasatinib, erlotinib, gefitinib, imatinib, sunitinib, and sorafenib all showed antiviral activity at micromolar concentrations. The 50% effective concentration for erlotinib and sorafenib was within blood concentrations readily achieved in human subjects. Quantitative PCR is a convenient method for viral drug sensitivity testing for slow-growing viruses that do not readily produce cytopathic effect. TK inhibitors deserve further consideration as a potential therapeutic option for BKV-associated nephropathy and hemorrhagic cystitis.

  5. Characterization of an Enterococcus faecium small-colony variant isolated from blood culture.

    PubMed

    Gröbner, Sabine; Beck, Julia; Schaller, Martin; Autenrieth, Ingo B; Schulte, Berit

    2012-01-01

    Small-colony variants (SCVs) of bacteria are slow-growing subpopulations which can cause latent or recurrent infections due to better intracellular survival compared to their wild-type counterparts. Atypical colony morphology and altered biochemical profile may lead to failure in identification of SCV strains. We here report for the first time the isolation of an Enterococcus faecium SCV phenotype. The case of a 65-year-old woman with acute myeloid leukaemia who developed symptoms of sepsis during induction chemotherapy is presented. E. faecium with normal and SCV phenotype was isolated from blood cultures. At the same time urine culture was positive with E. faecium suggesting that bacteraemia originated from the urinary tract. The SCV phenotype was characterized by atypical growth behaviour. Electron microscopic analyses revealed perturbation of the separation of daughter cells and the accumulation of cell wall material. Accordingly, the SCV variant showed a dysfunction or lack of spontaneous autolysis whereas the normal phenotype did not. In contrast to conventional identification systems based on biochemical characteristics, the E. faecium SCV was precisely identified by MALDI-TOF MS analysis implemented in our laboratory. Hence, the increasing use of MALDI-TOF MS analysis for the identification of bacteria might be an appropriate tool for the detection of SCV variants, the diagnosis of which is of importance for the clinical outcome and the antibiotic treatment. Copyright © 2011. Published by Elsevier GmbH.

  6. Classification-based quantitative analysis of stable isotope labeling by amino acids in cell culture (SILAC) data.

    PubMed

    Kim, Seongho; Carruthers, Nicholas; Lee, Joohyoung; Chinni, Sreenivasa; Stemmer, Paul

    2016-12-01

    Stable isotope labeling by amino acids in cell culture (SILAC) is a practical and powerful approach for quantitative proteomic analysis. A key advantage of SILAC is the ability to simultaneously detect the isotopically labeled peptides in a single instrument run and so guarantee relative quantitation for a large number of peptides without introducing any variation caused by separate experiment. However, there are a few approaches available to assessing protein ratios and none of the existing algorithms pays considerable attention to the proteins having only one peptide hit. We introduce new quantitative approaches to dealing with SILAC protein-level summary using classification-based methodologies, such as Gaussian mixture models with EM algorithms and its Bayesian approach as well as K-means clustering. In addition, a new approach is developed using Gaussian mixture model and a stochastic, metaheuristic global optimization algorithm, particle swarm optimization (PSO), to avoid either a premature convergence or being stuck in a local optimum. Our simulation studies show that the newly developed PSO-based method performs the best among others in terms of F1 score and the proposed methods further demonstrate the ability of detecting potential markers through real SILAC experimental data. No matter how many peptide hits the protein has, the developed approach can be applicable, rescuing many proteins doomed to removal. Furthermore, no additional correction for multiple comparisons is necessary for the developed methods, enabling direct interpretation of the analysis outcomes. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. A simple, specific high-throughput enzyme-linked immunosorbent assay (ELISA) for quantitative determination of melatonin in cell culture medium.

    PubMed

    Li, Ye; Cassone, Vincent M

    2015-09-01

    A simple, specific, high-throughput enzyme-linked immunosorbent assay (ELISA) for quantitative determination of melatonin was developed for directly measuring melatonin in cell culture medium with 10% FBS. This assay adopts a commercial monoclonal melatonin antibody and melatonin-HRP conjugate, so it can be applied in multiple labs rapidly with low cost compared with commercial RIA and ELISA kits. In addition, the procedure is much simpler with only four steps: 1) sample/conjugate incubation, 2) plate washing, 3) TMB color reaction and 4) reading of results. The standards of the assay cover a wide working range from 100 pg/mL to 10 ng/mL. The sensitivity was 68 pg/mL in cell culture medium with 10% FBS and 26 pg/mL in PBS with as little as 25 μL sample volume. The recovery of melatonin from cell culture medium was 101.0%. The principal cross-reacting compound was 5-methoxytryptophol (0.1%). The variation coefficients of the assay, within and between runs, ranged between 6.68% and 15.76% in cell culture medium. The mean linearity of a series diluted cell culture medium sample was 105% (CV=5%), ranging between 98% and 111%, y=5.5263x+0.0646, R(2)=0.99. The assay enables small research and teaching labs to reliably measure this important neurohormone. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. A Comparative Study on Quantitative Assessment of Blood Flow and Vascularization in Polycystic Ovary Syndrome Patients and Normal Women Using Three-Dimensional Power Doppler Ultrasonography.

    PubMed

    Garg, Nitasha; Khaira, Harkiran Kaur; Kaur, Manjot; Sinha, Smita

    2018-04-01

    To compare the quantitative assessment of blood flow and vascularization of ovaries in polycystic ovary syndrome patients and normal women using three-dimensional power Doppler ultrasonography. This cross-sectional quantitative study was conducted on women of reproductive age group (15-45 years) attending Gynaecology OPD AIMSR, Bathinda, Punjab. Thirty women were enrolled in polycystic ovarian syndrome (PCOS) group and 30 healthy women in control group. Women were categorized as polycystic ovary syndrome according to Rotterdam's criteria. The women with PCOS underwent transvaginal USG Doppler on day 6 of the cycle using 3D power Doppler USG equipment (GE Voluson E8), and vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were measured. The mean values of VI, FI and VFI measured by power Doppler ultrasonography were significantly increased ( P value = 0.000) in women with PCOS when compared with healthy women. This study suggests that blood flow and vascularization measured by 3D power Doppler ultrasonography in ovaries of polycystic ovary syndrome patients were significantly more than the ovaries of normal women.

  9. Instant screening and verification of carbapenemase activity in Bacteroides fragilis in positive blood culture, using matrix-assisted laser desorption ionization--time of flight mass spectrometry.

    PubMed

    Johansson, Åsa; Nagy, Elisabeth; Sóki, József

    2014-08-01

    Rapid identification of isolates in positive blood cultures are of great importance to secure correct treatment of septicaemic patients. As antimicrobial resistance is increasing, rapid detection of resistance is crucial. Carbapenem resistance in Bacteroides fragilis associated with cfiA-encoded class B metallo-beta-lactamase is emerging. In our study we spiked blood culture bottles with 26 B. fragilis strains with various cfiA-status and ertapenem MICs. By using main spectra specific for cfiA-positive and cfiA-negative B. fragilis strains, isolates could be screened for resistance. To verify strains that were positive in the screening, a carbapenemase assay was performed where the specific peaks of intact and hydrolysed ertapenem were analysed with matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS). We show here that it is possible to correctly identify B. fragilis and to screen for enzymic carbapenem resistance directly from the pellet of positive blood cultures. The carbapenemase assay to verify the presence of the enzyme was successfully performed on the pellet from the direct identification despite the presence of blood components. The result of the procedure was achieved in 3 h. Also the Bruker mass spectrometric β-lactamase assay (MSBL assay) prototype software was proven not only to be based on an algorithm that correlated with the manual inspection of the spectra, but also to improve the interpretation by showing the variation in the dataset. © 2014 The Authors.

  10. Direct identification of bacteria from BacT/ALERT anaerobic positive blood cultures by MALDI-TOF MS: MALDI Sepsityper kit versus an in-house saponin method for bacterial extraction.

    PubMed

    Meex, Cécile; Neuville, Florence; Descy, Julie; Huynen, Pascale; Hayette, Marie-Pierre; De Mol, Patrick; Melin, Pierrette

    2012-11-01

    In cases of bacteraemia, a rapid species identification of the causal agent directly from positive blood culture broths could assist clinicians in the timely targeting of empirical antimicrobial therapy. For this purpose, we evaluated the direct identification of micro-organisms from BacT/ALERT (bioMérieux) anaerobic positive blood cultures without charcoal using the Microflex matrix-assisted laser desorption/ionization (MALDI) time of flight MS (Bruker), after bacterial extraction by using two different methods: the MALDI Sepsityper kit (Bruker) and an in-house saponin lysis method. Bruker's recommended criteria for identification were expanded in this study, with acceptance of the species identification when the first three results with the best matches with the MALDI Biotyper database were identical, whatever the scores were. In total, 107 monobacterial cultures and six polymicrobial cultures from 77 different patients were included in this study. Among monomicrobial cultures, we identified up to the species level 67 and 66 % of bacteria with the MALDI Sepsityper kit and the saponin method, respectively. There was no significant difference between the two extraction methods. The direct species identification was particularly inconclusive for Gram-positive bacteria, as only 58 and 52 % of them were identified to the species level with the MALDI Sepsityper kit and the saponin method, respectively. Results for Gram-negative bacilli were better, with 82.5 and 90 % of correct identification to the species level with the MALDI Sepsityper kit and the saponin method, respectively. No misidentifications were given by the direct procedures when compared with identifications provided by the conventional method. Concerning the six polymicrobial blood cultures, whatever the extraction method used, a correct direct identification was only provided for one of the isolated bacteria on solid medium in all cases. The analysis of the time-to-result demonstrated a reduction

  11. Comparison of Diagnostic Accuracy of Periprosthetic Tissue Culture in Blood Culture Bottles to That of Prosthesis Sonication Fluid Culture for Diagnosis of Prosthetic Joint Infection (PJI) by Use of Bayesian Latent Class Modeling and IDSA PJI Criteria for Classification.

    PubMed

    Yan, Qun; Karau, Melissa J; Greenwood-Quaintance, Kerryl E; Mandrekar, Jayawant N; Osmon, Douglas R; Abdel, Matthew P; Patel, Robin

    2018-06-01

    We have previously demonstrated that culturing periprosthetic tissue in blood culture bottles (BCBs) improves sensitivity compared to conventional agar and broth culture methods for diagnosis of prosthetic joint infection (PJI). We have also shown that prosthesis sonication culture improves sensitivity compared to periprosthetic tissue culture using conventional agar and broth methods. The purpose of this study was to compare the diagnostic accuracy of tissue culture in BCBs (subsequently referred to as tissue culture) to prosthesis sonication culture (subsequently referred to as sonicate fluid culture). We studied 229 subjects who underwent arthroplasty revision or resection surgery between March 2016 and October 2017 at Mayo Clinic in Rochester, Minnesota. Using the Infectious Diseases Society of America (IDSA) PJI diagnostic criteria (omitting culture criteria) as the gold standard, the sensitivity of tissue culture was similar to that of the sonicate fluid culture (66.4% versus 73.1%, P = 0.07) but was significantly lower than that of the two tests combined (66.4% versus 76.9%, P < 0.001). Using Bayesian latent class modeling, which assumes no gold standard for PJI diagnosis, the sensitivity of tissue culture was slightly lower than that of sonicate fluid culture (86.3% versus 88.7%) and much lower than that of the two tests combined (86.3% versus 99.1%). In conclusion, tissue culture in BCBs reached sensitivity similar to that of prosthesis sonicate fluid culture for diagnosis of PJI, but the two tests combined had the highest sensitivity without compromising specificity. The combination of tissue culture in BCBs and sonicate fluid culture is recommended to achieve the highest level of microbiological diagnosis of PJI. Copyright © 2018 American Society for Microbiology.

  12. Comparative analysis of Micrococcus luteus isolates from blood cultures of patients with pulmonary hypertension receiving epoprostenol continuous infusion.

    PubMed

    Hirata, Yoshinori; Sata, Makoto; Makiuchi, Yuko; Morikane, Keita; Wada, Akihito; Okabe, Nobuhiko; Tomoike, Hitonobu

    2009-12-01

    During the period 2002-2008, at the National Cardiovascular Center, Osaka, 28 Micrococcus luteus isolates and one Kocuria spp. isolate were obtained from blood cultures of pulmonary hypertension (PH) patients who were receiving continuous infusion therapy with epoprostenol. Pulsed-field gel electrophoresis patterns of the isolates were unrelated, suggesting that the infections had multiple origins. The preparation of epoprostenol solution by patients themselves was thought to be a risk factor.

  13. Is quantitative PCR for the pneumolysin (ply) gene useful for detection of pneumococcal lower respiratory tract infection?

    PubMed

    Abdeldaim, G; Herrmann, B; Korsgaard, J; Olcén, P; Blomberg, J; Strålin, K

    2009-06-01

    The pneumolysin (ply) gene is widely used as a target in PCR assays for Streptococcus pneumoniae in respiratory secretions. However, false-positive results with conventional ply-based PCR have been reported. The aim here was to study the performance of a quantitative ply-based PCR for the identification of pneumococcal lower respiratory tract infection (LRTI). In a prospective study, fibreoptic bronchoscopy was performed in 156 hospitalized adult patients with LRTI and 31 controls who underwent bronchoscopy because of suspicion of malignancy. Among the LRTI patients and controls, the quantitative ply-based PCR applied to bronchoalveolar lavage (BAL) fluid was positive at >or=10(3) genome copies/mL in 61% and 71% of the subjects, at >or=10(5) genome copies/mL in 40% and 58% of the subjects, and at >or=10(7) genome copies/mL in 15% and 3.2% of the subjects, respectively. Using BAL fluid culture, blood culture, and/or a urinary antigen test, S. pneumoniae was identified in 19 LRTI patients. As compared with these diagnostic methods used in combination, quantitative ply-based PCR showed sensitivities and specificities of 89% and 43% at a cut-off of 10(3) genome copies/mL, of 84% and 66% at a cut-off of 10(5) genome copies/mL, and of 53% and 90% at a cut-off of 10(7) genome copies/mL, respectively. In conclusion, a high cut-off with the quantitative ply-based PCR was required to reach acceptable specificity. However, as a high cut-off resulted in low sensitivity, quantitative ply-based PCR does not appear to be clinically useful. Quantitative PCR methods for S. pneumoniae using alternative gene targets should be evaluated.

  14. Coagulation monitoring based on blood elastic measurement using optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Xu, Xiangqun; Zhu, Jiang; Chen, Zhongping

    2017-02-01

    Blood coagulation monitoring is important to diagnose hematological diseases and cardiovascular diseases and to predict the risk of bleeding and excessive clotting. In this study, we developed a system to dynamically monitor blood coagulation and quantitatively determine the coagulation function by blood elastic measurement. When blood forms a clot from a liquid, ultrasonic force induces a shear wave, which is detected by optical coherence tomography (OCT). The coagulation of porcine whole blood recalcified by calcium chloride is assessed using the metrics of reaction time, clot formation kinetics and maximum shear modulus. The OCE system can noninvasively monitor the blood coagulation and quantitatively determine the coagulation function.

  15. Development of cultured Plasmodium falciparum blood-stage malaria cell banks for early phase in vivo clinical trial assessment of anti-malaria drugs and vaccines.

    PubMed

    Stanisic, Danielle I; Liu, Xue Q; De, Sai Lata; Batzloff, Michael R; Forbes, Tanya; Davis, Christopher B; Sekuloski, Silvana; Chavchich, Marina; Chung, Wendy; Trenholme, Katharine; McCarthy, James S; Li, Tao; Sim, B Kim Lee; Hoffman, Stephen L; Good, Michael F

    2015-04-07

    The ability to undertake controlled human malaria infection (CHMI) studies for preliminary evaluation of malaria vaccine candidates and anti-malaria drug efficacy has been limited by the need for access to sporozoite infected mosquitoes, aseptic, purified, cryopreserved sporozoites or blood-stage malaria parasites derived ex vivo from malaria infected individuals. Three different strategies are described for the manufacture of clinical grade cultured malaria cell banks suitable for use in CHMI studies. Good Manufacturing Practices (GMP)-grade Plasmodium falciparum NF54, clinically isolated 3D7, and research-grade P. falciparum 7G8 blood-stage malaria parasites were cultured separately in GMP-compliant facilities using screened blood components and then cryopreserved to produce three P. falciparum blood-stage malaria cell banks. These cell banks were evaluated according to specific criteria (parasitaemia, identity, viability, sterility, presence of endotoxin, presence of mycoplasma or other viral agents and in vitro anti-malarial drug sensitivity of the cell bank malaria parasites) to ensure they met the criteria to permit product release according to GMP requirements. The P. falciparum NF54, 3D7 and 7G8 cell banks consisted of >78% ring stage parasites with a ring stage parasitaemia of >1.4%. Parasites were viable in vitro following thawing. The cell banks were free from contamination with bacteria, mycoplasma and a broad panel of viruses. The P. falciparum NF54, 3D7 and 7G8 parasites exhibited differential anti-malarial drug susceptibilities. The P. falciparum NF54 and 3D7 parasites were susceptible to all anti-malaria compounds tested, whereas the P. falciparum 7G8 parasites were resistant/had decreased susceptibility to four compounds. Following testing, all defined release criteria were met and the P. falciparum cell banks were deemed suitable for release. Ethical approval has been obtained for administration to human volunteers. The production of cultured P

  16. Low Mass Blood Peptides Discriminative of Inflammatory Bowel Disease (IBD) Severity: A Quantitative Proteomic Perspective*

    PubMed Central

    Yau, Yunki; Duo, Xizi; Zeng, Ming; Campbell, Beth; Shin, Sean; Luber, Raphael; Redmond, Diane; Leong, Rupert W. L.

    2016-01-01

    Breakdown of the protective gut barrier releases effector molecules and degradation products into the blood stream making serum and plasma ideal as a diagnostic medium. The enriched low mass proteome is unexplored as a source of differentiators for diagnosing and monitoring inflammatory bowel disease (IBD) activity, that is less invasive than colonoscopy. Differences in the enriched low mass plasma proteome (<25 kDa) were assessed by label-free quantitative mass-spectrometry. A panel of marker candidates were progressed to validation phase and “Tier-2” FDA-level validated quantitative assay. Proteins important in maintaining gut barrier function and homeostasis at the epithelial interface have been quantitated by multiple reaction monitoring in plasma and serum including both inflammatory; rheumatoid arthritis controls, and non-inflammatory healthy controls; ulcerative colitis (UC), and Crohn's disease (CD) patients. Detection by immunoblot confirmed presence at the protein level in plasma. Correlation analysis and receiver operator characteristics were used to report the sensitivity and specificity. Peptides differentiating controls from IBD originate from secreted phosphoprotein 24 (SPP24, p = 0.000086, 0.009); whereas those in remission and healthy can be differentiated in UC by SPP24 (p = 0.00023, 0.001), α-1-microglobulin (AMBP, p = 0.006) and CD by SPP24 (p = 0.019, 0.05). UC and CD can be differentiated by Guanylin (GUC2A, p = 0.001), and Secretogranin-1 (CHGB p = 0.035). Active and quiescent disease can also be differentiated in UC and CD by CHGB (p ≤ 0.023) SPP24 (p ≤ 0.023) and AMBP (UC p = 0.046). Five peptides discriminating IBD activity and severity had very little-to-no correlation to erythrocyte sedimentation rate, C-reactive protein, white cell or platelet counts. Three of these peptides were found to be binding partners to SPP24 protein alongside other known matrix proteins. These proteins have the potential to improve diagnosis and

  17. Blood-brain barrier permeability and monocyte infiltration in experimental allergic encephalomyelitis: a quantitative MRI study.

    PubMed

    Floris, S; Blezer, E L A; Schreibelt, G; Döpp, E; van der Pol, S M A; Schadee-Eestermans, I L; Nicolay, K; Dijkstra, C D; de Vries, H E

    2004-03-01

    Enhanced cerebrovascular permeability and cellular infiltration mark the onset of early multiple sclerosis lesions. So far, the precise sequence of these events and their role in lesion formation and disease progression remain unknown. Here we provide quantitative evidence that blood-brain barrier leakage is an early event and precedes massive cellular infiltration in the development of acute experimental allergic encephalomyelitis (EAE), the animal correlate of multiple sclerosis. Cerebrovascular leakage and monocytes infiltrates were separately monitored by quantitative in vivo MRI during the course of the disease. Magnetic resonance enhancement of the contrast agent gadolinium diethylenetriaminepentaacetate (Gd-DTPA), reflecting vascular leakage, occurred concomitantly with the onset of neurological signs and was already at a maximal level at this stage of the disease. Immunohistochemical analysis also confirmed the presence of the serum-derived proteins such as fibrinogen around the brain vessels early in the disease, whereas no cellular infiltrates could be detected. MRI further demonstrated that Gd-DTPA leakage clearly preceded monocyte infiltration as imaged by the contrast agent based on ultra small particles of iron oxide (USPIO), which was maximal only during full-blown EAE. Ultrastructural and immunohistochemical investigation revealed that USPIOs were present in newly infiltrated macrophages within the inflammatory lesions. To validate the use of USPIOs as a non-invasive tool to evaluate therapeutic strategies, EAE animals were treated with the immunomodulator 3-hydroxy-3-methylglutaryl Coenzyme A reductase inhibitor, lovastatin, which ameliorated clinical scores. MRI showed that the USPIO load in the brain was significantly diminished in lovastatin-treated animals. Data indicate that cerebrovascular leakage and monocytic trafficking into the brain are two distinct processes in the development of inflammatory lesions during multiple sclerosis, which can

  18. Bartonella Species, an Emerging Cause of Blood-Culture-Negative Endocarditis.

    PubMed

    Okaro, Udoka; Addisu, Anteneh; Casanas, Beata; Anderson, Burt

    2017-07-01

    Since the reclassification of the genus Bartonella in 1993, the number of species has grown from 1 to 45 currently designated members. Likewise, the association of different Bartonella species with human disease continues to grow, as does the range of clinical presentations associated with these bacteria. Among these, blood-culture-negative endocarditis stands out as a common, often undiagnosed, clinical presentation of infection with several different Bartonella species. The limitations of laboratory tests resulting in this underdiagnosis of Bartonella endocarditis are discussed. The varied clinical picture of Bartonella infection and a review of clinical aspects of endocarditis caused by Bartonella are presented. We also summarize the current knowledge of the molecular basis of Bartonella pathogenesis, focusing on surface adhesins in the two Bartonella species that most commonly cause endocarditis, B. henselae and B. quintana . We discuss evidence that surface adhesins are important factors for autoaggregation and biofilm formation by Bartonella species. Finally, we propose that biofilm formation is a critical step in the formation of vegetative masses during Bartonella -mediated endocarditis and represents a potential reservoir for persistence by these bacteria. Copyright © 2017 American Society for Microbiology.

  19. The effects of a culturally-tailored campaign to increase blood donation knowledge, attitudes and intentions among African migrants in two Australian States: Victoria and South Australia

    PubMed Central

    Polonsky, Michael J.; Jones, Sandra C.; Renzaho, Andre M. N.

    2017-01-01

    Research suggests that African migrants are often positively predisposed towards blood donation, but are under-represented in participation. A culturally-tailored intervention targeting the African migrant community in Australia was developed and implemented, to enhance knowledge about blood donation, improve attitudes towards donating, increase intentions to donate blood, and increase the number of new African donors in Australia. Four weeks after a targeted campaign, a survey evaluation process commenced, administered face-to-face by bilingual interviewers from the African community in Melbourne and Adelaide, Australia (community survey). The questionnaires covered demographics, campaign awareness, blood donation knowledge and intentions, medical mistrust and perceived discrimination, and were analysed to evaluate changes in knowledge and intention. Sixty-two percent of survey participants (n = 454) reported being aware of the campaign. With increasing campaign awareness, there was a 0.28 increase in knowledge score (p = .005); previous blood donation was also associated with an increased blood donation knowledge score. Blood donation intention scores were not associated with campaign awareness (p = 0.272), but were associated with previous blood donation behaviour and a positive blood donation attitude score. More positive scores on the blood donation attitude measure were associated with increasing blood donation intentions, self-efficacy and campaign awareness (score increases of 0.27, 0.30 and 0.04, respectively, all p<0.05). Data were collected on the ethnicity of new blood donors in six blood collection centres before and after the intervention, and independent of the intervention evaluation survey. These data were also used to assess behavioural changes and the proportions of donors from different countries before and after the survey. There was no difference in the number of new African migrant donors, before and after the intervention. The culturally

  20. The effects of a culturally-tailored campaign to increase blood donation knowledge, attitudes and intentions among African migrants in two Australian States: Victoria and South Australia.

    PubMed

    Francis, Kate L; Polonsky, Michael J; Jones, Sandra C; Renzaho, Andre M N

    2017-01-01

    Research suggests that African migrants are often positively predisposed towards blood donation, but are under-represented in participation. A culturally-tailored intervention targeting the African migrant community in Australia was developed and implemented, to enhance knowledge about blood donation, improve attitudes towards donating, increase intentions to donate blood, and increase the number of new African donors in Australia. Four weeks after a targeted campaign, a survey evaluation process commenced, administered face-to-face by bilingual interviewers from the African community in Melbourne and Adelaide, Australia (community survey). The questionnaires covered demographics, campaign awareness, blood donation knowledge and intentions, medical mistrust and perceived discrimination, and were analysed to evaluate changes in knowledge and intention. Sixty-two percent of survey participants (n = 454) reported being aware of the campaign. With increasing campaign awareness, there was a 0.28 increase in knowledge score (p = .005); previous blood donation was also associated with an increased blood donation knowledge score. Blood donation intention scores were not associated with campaign awareness (p = 0.272), but were associated with previous blood donation behaviour and a positive blood donation attitude score. More positive scores on the blood donation attitude measure were associated with increasing blood donation intentions, self-efficacy and campaign awareness (score increases of 0.27, 0.30 and 0.04, respectively, all p<0.05). Data were collected on the ethnicity of new blood donors in six blood collection centres before and after the intervention, and independent of the intervention evaluation survey. These data were also used to assess behavioural changes and the proportions of donors from different countries before and after the survey. There was no difference in the number of new African migrant donors, before and after the intervention. The culturally

  1. A Triple Culture Model of the Blood-Brain Barrier Using Porcine Brain Endothelial cells, Astrocytes and Pericytes.

    PubMed

    Thomsen, Louiza Bohn; Burkhart, Annette; Moos, Torben

    2015-01-01

    In vitro blood-brain barrier (BBB) models based on primary brain endothelial cells (BECs) cultured as monoculture or in co-culture with primary astrocytes and pericytes are useful for studying many properties of the BBB. The BECs retain their expression of tight junction proteins and efflux transporters leading to high trans-endothelial electric resistance (TEER) and low passive paracellular permeability. The BECs, astrocytes and pericytes are often isolated from small rodents. Larger species as cows and pigs however, reveal a higher yield, are readily available and have a closer resemblance to humans, which make them favorable high-throughput sources for cellular isolation. The aim of the present study has been to determine if the preferable combination of purely porcine cells isolated from the 6 months old domestic pigs, i.e. porcine brain endothelial cells (PBECs) in co-culture with porcine astrocytes and pericytes, would compare with PBECs co-cultured with astrocytes and pericytes isolated from newborn rats with respect to TEER value and low passive permeability. The astrocytes and pericytes were grown both as contact and non-contact co-cultures as well as in triple culture to examine their effects on the PBECs for barrier formation as revealed by TEER, passive permeability, and expression patterns of tight junction proteins, efflux transporters and the transferrin receptor. This syngenic porcine in vitro BBB model is comparable to triple cultures using PBECs, rat astrocytes and rat pericytes with respect to TEER formation, low passive permeability, and expression of hallmark proteins signifying the brain endothelium (tight junction proteins claudin 5 and occludin, the efflux transporters P-glycoprotein (PgP) and breast cancer related protein (BCRP), and the transferrin receptor).

  2. Impact of definition and procedures used for absent blood culture data on the rate of intravascular catheter infection during parenteral nutrition.

    PubMed

    Austin, P D; Hand, K S; Elia, M

    2016-06-01

    Diagnosis of intravascular catheter infection may be affected by the definition and procedures applied in the absence of blood culture data. To examine the extent to which different definitions of catheter infection and procedures for handling absent blood culture data can affect reported catheter infection rates. Catheter infection rates were established in a cohort of hospitalized patients administered parenteral nutrition according to three clinical and four published definitions. Paired and unpaired comparisons were made using available case analyses, sensitivity analyses and intention-to-categorize analyses. Complete data were available for each clinical definition (N = 193), and there were missing data (4.1-26.9%) for the published definitions. In an available case analysis, the catheter infection rate was 13.0-36.8% for the clinical definitions and 2.1-12.4% for the published definitions. For the published definitions, the rate was 1.6-32.1% in a sensitivity analysis and 11.4-16.9% in an intention-to-categorize analysis, with suggestion of bias towards a higher catheter infection rate in those with missing data, in keeping with the analyses of the clinical definitions. For paired comparisons, the strength of agreement between definitions varied from 'poor' (Cohen's kappa <0.21) to 'very good' (Cohen's kappa ≥0.81). The use of different definitions of catheter infection and procedures applied in the absence of blood culture data produced widely different catheter infection rates, which could compromise measurements or comparisons of service quality or study outcome. As such, there is a need to establish and use a valid, consistent and practical definition. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  3. Quantitation of 25-hydroxyvitamin D in dried blood spots by 2D LC-MS/MS without derivatization and correlation with serum in adult and pediatric studies.

    PubMed

    Jensen, Berit P; Saraf, Rajneeta; Ma, Jing; Berry, Sarah; Grant, Cameron C; Camargo, Carlos A; Sies, Christiaan W

    2018-06-01

    Demand for measurement of 25-hydroxyvitamin D (25OHD) is growing and dried blood spot (DBS) sampling is attractive as samples are easier to collect, transport and store. A 2D LC-MS/MS assay without derivatization was developed. DBS punches (3.2 mm) were ultrasonicated with d 6 -25OHD 3 in 70% methanol followed by hexane extraction, dry-down and reconstitution. The assay was validated and applied to two studies comparing whole blood adult DBS with serum samples (n = 40) and neonatal whole blood DBS with cord serum samples (n = 80). The assay was validated in whole blood DBS over the range 13-106 nmol/L 25OHD 3 and 11-91 nmol/L 25OHD 2 with a limit of detection of 3 nmol/L. Intra- and inter-day imprecision was <13% CV and bias <12%. The assay had high recovery and minimal matrix effects. Triplicate DBS study samples had a mean CV of ≤13% for 25OHD 3. No 25OHD 2 was detected. DBS calculated serum 25OHD 3 concentrations correlated strongly with serum concentrations in the adult DBS/serum study (r = 0.94) and moderately in the neonatal DBS/cord serum study (r = 0.69). Direct quantitation of 25OHD in DBS by 2D LC-MS/MS without derivatization was found to be an alternative to serum quantitation applicable to clinical research studies on adult DBS samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. [Fever during blood transfusion. A case of coincidence instead of causality].

    PubMed

    Strobel, E; Bender, H-U

    2013-10-01

    A boy aged 2 years and 5 months showed agitation, shivering and fever with a temperature of 38.9 °C during a red blood cell transfusion. Examination of the assumed adverse transfusion reaction gave no indications of erythrocyte incompatibility, hemolysis or IgA incompatibility. No antibodies against HLA class I antigens or HPA antigens were found in the recipient's blood. Sterility testing of the blood product showed no growth, but in the blood cultures taken from the patient immediately after the blood transfusion, Enterobacter cloacae was detected which also could be found in blood cultures and nose and throat swabs taken 3 days before. Therefore, the fever during blood transfusion was not a case of causality but of coincidence. This case underlines the recommendation to examine blood cultures from the recipient in all suspected cases of adverse transfusion reaction.

  5. Evaluation of the LightCycler Staphylococcus M GRADE kits on positive blood cultures that contained gram-positive cocci in clusters.

    PubMed

    Shrestha, Nabin K; Tuohy, Marion J; Padmanabhan, Ravindran A; Hall, Gerri S; Procop, Gary W

    2005-12-01

    We evaluated the Roche LightCycler Staphylococcus M(GRADE) kits to differentiate between Staphylococcus aureus and coagulase-negative staphylococci in blood cultures growing clusters of gram-positive cocci. Testing 100 bottles (36 containing S. aureus), the assay was 100% sensitive and 98.44% specific for S. aureus and 100% sensitive and specific for coagulase-negative staphylococci.

  6. Quantitative phase imaging of human red blood cells using phase-shifting white light interference microscopy with colour fringe analysis

    NASA Astrophysics Data System (ADS)

    Singh Mehta, Dalip; Srivastava, Vishal

    2012-11-01

    We report quantitative phase imaging of human red blood cells (RBCs) using phase-shifting interference microscopy. Five phase-shifted white light interferograms are recorded using colour charge coupled device camera. White light interferograms were decomposed into red, green, and blue colour components. The phase-shifted interferograms of each colour were then processed by phase-shifting analysis and phase maps for red, green, and blue colours were reconstructed. Wavelength dependent refractive index profiles of RBCs were computed from the single set of white light interferogram. The present technique has great potential for non-invasive determination of refractive index variation and morphological features of cells and tissues.

  7. Development of a solvent-free analytical method for paracetamol quantitative determination in Blood Brain Barrier in vitro model.

    PubMed

    Langlois, Marie-Hélène; Vekris, Antonios; Bousses, Christine; Mordelet, Elodie; Buhannic, Nathalie; Séguard, Céline; Couraud, Pierre-Olivier; Weksler, Babette B; Petry, Klaus G; Gaudin, Karen

    2015-04-15

    A Reversed Phase-High Performance Liquid Chromatography/Diode Array Detection method was developed and validated for paracetamol quantification in cell culture fluid from an in vitro Blood Brain Barrier model. The chromatographic method and sample preparation were developed using only aqueous solvents. The column was a XTerra RP18 150 × 4.6mm, 3.5 μm with a guard column XTerra RP18 20 × 4.6 mm, 3.5 μm at 35 °C and the mobile phase was composed by 100% formate buffer 20 mM at pH 4 and flow rate was set at 1 mL/min. The detection was at 242 nm. The sample was injected at 10 μL. Validation was performed using the accuracy profile approach. The analytical procedure was validated with the acceptance limits at ± 10% over a range of concentration from 1 to 58 mg L(-1). The procedure was then used in routine to determine paracetamol concentration in a brain blood barrier in vitro model. Application of the Unither paracetamol formulation in Blood Brain Barrier model allowed the determination and comparison of the transcellular passage of paracetamol at 37 °C and 4 °C, that excludes paracellular or non specific leakage. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Blood analysis by Raman spectroscopy.

    PubMed

    Enejder, Annika M K; Koo, Tae-Woong; Oh, Jeankun; Hunter, Martin; Sasic, Slobodan; Feld, Michael S; Horowitz, Gary L

    2002-11-15

    Concentrations of multiple analytes were simultaneously measured in whole blood with clinical accuracy, without sample processing, using near-infrared Raman spectroscopy. Spectra were acquired with an instrument employing nonimaging optics, designed using Monte Carlo simulations of the influence of light-scattering-absorbing blood cells on the excitation and emission of Raman light in turbid medium. Raman spectra were collected from whole blood drawn from 31 individuals. Quantitative predictions of glucose, urea, total protein, albumin, triglycerides, hematocrit, and hemoglobin were made by means of partial least-squares (PLS) analysis with clinically relevant precision (r(2) values >0.93). The similarity of the features of the PLS calibration spectra to those of the respective analyte spectra illustrates that the predictions are based on molecular information carried by the Raman light. This demonstrates the feasibility of using Raman spectroscopy for quantitative measurements of biomolecular contents in highly light-scattering and absorbing media.

  9. Matrix-assisted laser desorption ionization-time of flight mass spectrometry for direct bacterial identification from positive blood culture pellets.

    PubMed

    Prod'hom, Guy; Bizzini, Alain; Durussel, Christian; Bille, Jacques; Greub, Gilbert

    2010-04-01

    An ammonium chloride erythrocyte-lysing procedure was used to prepare a bacterial pellet from positive blood cultures for direct matrix-assisted laser desorption-ionization time of flight (MALDI-TOF) mass spectrometry analysis. Identification was obtained for 78.7% of the pellets tested. Moreover, 99% of the MALDI-TOF identifications were congruent at the species level when considering valid scores. This fast and accurate method is promising.

  10. Time to positivity of blood cultures in patients with bloodstream infections: A useful prognostic tool.

    PubMed

    Martín-Gutiérrez, Guillermo; Martín-Pérez, Carlos; Gutiérrez-Pizarraya, Antonio; Lepe, José A; Cisneros, José M; Aznar, Javier

    2017-12-01

    The time to positivity (TTP) of blood cultures in patients with bloodstream infections (BSIs) has been considered to be a possible prognostic tool for some bacterial species. However, notable differences have been found between sampling designs and statistical methods in published studies to date, which makes it difficult to compare results or to derive reliable conclusions. Our objective was to evaluate the clinical and microbiological implications of TTP among patients with BSI caused by the most common pathogens. A total of 361 episodes of BSI were reported for 332 patients. The survival of the entire cohort was measured from the time of blood culture sampling. In order to compare our results with those of previous studies, TTP was divided in three different groups based on log rank (short TTP <12h; medium TTP ≥12h to ≤27h, and long TTP >27h). Cox proportional hazard models were used to calculate crude and adjusted hazard ratios (HR). The Cox proportional hazard model revealed that TTP is an independent predictor of mortality (HR=1.00, p=0.031) in patients with BSIs. A higher mortality was found in the group of patients with the shortest TTP (<12h) (HR=2.100, p=0.047), as well as those with longest TTP (>27h) (HR=3.277, p=0.031). It seems that TTP may provide a useful prognostic tool associated with a higher risk of mortality, not only in patients with shorter TTP, but also in those with longer TTP. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  11. Biocompatible and label-free separation of cancer cells from cell culture lines from white blood cells in ferrofluids.

    PubMed

    Zhao, Wujun; Cheng, Rui; Lim, So Hyun; Miller, Joshua R; Zhang, Weizhong; Tang, Wei; Xie, Jin; Mao, Leidong

    2017-06-27

    This paper reports a biocompatible and label-free cell separation method using ferrofluids that can separate a variety of low-concentration cancer cells from cell culture lines (∼100 cancer cells per mL) from undiluted white blood cells, with a throughput of 1.2 mL h -1 and an average separation efficiency of 82.2%. The separation is based on the size difference of the cancer cells and white blood cells, and is conducted in a custom-made biocompatible ferrofluid that retains not only excellent short-term viabilities but also normal proliferations of 7 commonly used cancer cell lines. A microfluidic device is designed and optimized specifically to shorten the time of live cells' exposure to ferrofluids from hours to seconds, by eliminating time-consuming off-chip sample preparation and extraction steps and integrating them on-chip to achieve a one-step process. As a proof-of-concept demonstration, a ferrofluid with 0.26% volume fraction was used in this microfluidic device to separate spiked cancer cells from cell lines at a concentration of ∼100 cells per mL from white blood cells with a throughput of 1.2 mL h -1 . The separation efficiencies were 80 ± 3%, 81 ± 5%, 82 ± 5%, 82 ± 4%, and 86 ± 6% for A549 lung cancer, H1299 lung cancer, MCF-7 breast cancer, MDA-MB-231 breast cancer, and PC-3 prostate cancer cell lines, respectively. The separated cancer cells' purity was between 25.3% and 28.8%. In addition, the separated cancer cells from this strategy showed an average short-term viability of 94.4 ± 1.3%, and these separated cells were cultured and demonstrated normal proliferation to confluence even after the separation process. Owing to its excellent biocompatibility and label-free operation and its ability to recover low concentrations of cancer cells from white blood cells, this method could lead to a promising tool for rare cell separation.

  12. Membrane culture and reduced oxygen tension enhances cartilage matrix formation from equine cord blood mesenchymal stromal cells in vitro.

    PubMed

    Co, C; Vickaryous, M K; Koch, T G

    2014-03-01

    Ongoing research is aimed at increasing cartilage tissue yield and quality from multipotent mesenchymal stromal cells (MSC) for the purpose of treating cartilage damage in horses. Low oxygen culture has been shown to enhance chondrogenesis, and novel membrane culture has been proposed to increase tissue yield and homogeneity. The objective of this study was to evaluate and compare the effect of reduced oxygen and membrane culture during in vitro chondrogenesis of equine cord blood (CB) MSC. CB-MSC (n = 5 foals) were expanded at 21% oxygen prior to 3-week differentiation in membrane or pellet culture at 5% and 21% oxygen. Assessment included histological examination (H&E, toluidine Blue, immunohistochemistry (IHC) for collagen type I and II), protein quantification by hydroxyproline assay and dimethylmethylene assay, and mRNA analysis for collagen IA1, collagen IIA1, collagen XA1, HIF1α and Sox9. Among treatment groups, 5% membrane culture produced neocartilage most closely resembling hyaline cartilage. Membrane culture resulted in increased wet mass, homogenous matrix morphology and an increase in total collagen content, while 5% oxygen culture resulted in higher GAG and type II collagen content. No significant differences were observed for mRNA analysis. Membrane culture at 5% oxygen produces a comparatively larger amount of higher quality neocartilage. Matrix homogeneity is attributed to a uniform diffusion gradient and reduced surface tension. Membrane culture holds promise for scale-up for therapeutic purposes, for cellular preconditioning prior to cytotherapeutic applications, and for modeling system for gas-dependent chondrogenic differentiation studies. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  13. Epidemic microclusters of blood-culture proven sepsis in very-low-birth weight infants: experience of the German Neonatal Network.

    PubMed

    Härtel, Christoph; Faust, Kirstin; Avenarius, Stefan; Bohnhorst, Bettina; Emeis, Michael; Gebauer, Corinna; Groneck, Peter; Heitmann, Friedhelm; Hoehn, Thomas; Hubert, Mechthild; Kribs, Angela; Küster, Helmut; Laux, Reinhard; Mögel, Michael; Müller, Dirk; Olbertz, Dirk; Roll, Claudia; Siegel, Jens; Stein, Anja; Vochem, Matthias; Weller, Ursula; von der Wense, Axel; Wieg, Christian; Wintgens, Jürgen; Hemmelmann, Claudia; Simon, Arne; Herting, Egbert; Göpel, Wolfgang

    2012-01-01

    We evaluated blood culture-proven sepsis episodes occurring in microclusters in very-low-birth-weight infants born in the German Neonatal Network (GNN) during 2009-2010. Thirty-seven centers participated in GNN; 23 centers enrolled ≥50 VLBW infants in the study period. Data quality was approved by on-site monitoring. Microclusters of sepsis were defined as occurrence of at least two blood-culture proven sepsis events in different patients of one center within 3 months with the same bacterial species. For microcluster analysis, we selected sepsis episodes with typically cross-transmitted bacteria of high clinical significance including gram-negative rods and Enterococcus spp. In our cohort, 12/2110 (0.6%) infants were documented with an early-onset sepsis and 235 late-onset sepsis episodes (≥72 h of age) occurred in 203/2110 (9.6%) VLBW infants. In 182/235 (77.4%) late-onset sepsis episodes gram-positive bacteria were documented, while coagulase negative staphylococci were found to be the most predominant pathogens (48.5%, 95%CI: 42.01-55.01). Candida spp. and gram-negative bacilli caused 10/235 (4.3%, 95%CI: 1.68% -6.83%) and 43/235 (18.5%) late-onset sepsis episodes, respectively. Eleven microclusters of blood-culture proven sepsis were detected in 7 hospitals involving a total 26 infants. 16/26 cluster patients suffered from Klebsiella spp. sepsis. The median time interval between the first patient's Klebsiella spp. sepsis and cluster cases was 14.1 days (interquartile range: 1-27 days). First patients in the cluster, their linked cases and sporadic sepsis events did not show significant differences in short term outcome parameters. Microclusters of infection are an important phenomenon for late-onset sepsis. Most gram-negative cluster infections occur within 30 days after the first patient was diagnosed and Klebsiella spp. play a major role. It is essential to monitor epidemic microclusters of sepsis in surveillance networks to adapt clinical practice

  14. [Fluorescence quantitative PCR detection of WT1 gene expression in peripheral blood of patients with acute leukemias and its clinical implications].

    PubMed

    Bai, Bo; Wang, Hong-Wei; Xu, Yong-Qun; Yang, Hei-Nu; Qiao, Zhen-Hua

    2005-08-01

    To elucidate the expression of WT1 in all types of leukemias and its implications for monitoring minimal residual disease in patients with acute leukemia, the peripheral blood from 55 leukemia patients and 10 normal voluteer was detected by using FQ-RT-PCR. Follow-up monitoring of WT1 expression of peripheral blood was performed for 20 patients with acute leukemia. The results showed that the expression of WT1 gene in all types of leukemias was significantly higher than that in normal control (P < 0.001). For ANLL and ALL patients, the survival time in the group of WT1 6.8 x 10(-3), (P = 0.027). Follow-up detection of the expression of WT1 in peripheral blood samples from 20 acute leukemia patients, 7 cases relapsed after complete remission has been done. In 5 of 7 relapsed patients, the expression of WT1 had obviously increased about 2 - 3 months before clinical relapse became apparent. It is concluded that the established FQ-RT-PCR method is accurate and specific. The expression of WT1 gene is relatively high in all types of leukemias compared with normal peripheral blood cells, the higher WT1 expression may associate with poor prognosis in acute leukemia, and the dynamics of WT1 level correlate with the disease status. The quantitative assessment of WT1 expression in peripheral blood samples by FQ-RT-PCR may be a useful tool for monitoring minimal residual disease.

  15. Transfection of brain capillary endothelial cells in primary culture with defined blood-brain barrier properties.

    PubMed

    Burkhart, Annette; Thomsen, Louiza Bohn; Thomsen, Maj Schneider; Lichota, Jacek; Fazakas, Csilla; Krizbai, István; Moos, Torben

    2015-08-07

    Primary brain capillary endothelial cells (BCECs) are a promising tool to study the blood-brain barrier (BBB) in vitro, as they maintain many important characteristics of the BBB in vivo, especially when co-cultured with pericytes and/or astrocytes. A novel strategy for drug delivery to the brain is to transform BCECs into protein factories by genetic modifications leading to secretion of otherwise BBB impermeable proteins into the central nervous system. However, a huge challenge underlying this strategy is to enable transfection of non-mitotic BCECs, taking a non-viral approach. We therefore aimed to study transfection in primary, non-mitotic BCECs cultured with defined BBB properties without disrupting the cells' integrity. Primary cultures of BCECs, pericytes and astrocytes were generated from rat brains and used in three different in vitro BBB experimental arrangements, which were characterised based on a their expression of tight junction proteins and other BBB specific proteins, high trans-endothelial electrical resistance (TEER), and low passive permeability to radiolabeled mannitol. Recombinant gene expression and protein synthesis were examined in primary BCECs. The BCECs were transfected using a commercially available transfection agent Turbofect™ to express the red fluorescent protein HcRed1-C1. The BCECs were transfected at different time points to monitor transfection in relation to mitotic or non-mitotic cells, as indicated by fluorescence-activated cell sorting analysis after 5-and 6-carboxylfluorescein diacetate succinidyl ester incorporation. The cell cultures exhibited important BBB characteristics judged from their expression of BBB specific proteins, high TEER values, and low passive permeability. Among the three in vitro BBB models, co-culturing with BCECs and astrocytes was well suited for the transfection studies. Transfection was independent of cell division and with equal efficacy between the mitotic and non-mitotic BCECs. Importantly

  16. Gold nanoparticle-based RT-PCR and real-time quantitative RT-PCR assays for detection of Japanese encephalitis virus

    NASA Astrophysics Data System (ADS)

    Huang, Su-Hua; Yang, Tsuey-Ching; Tsai, Ming-Hong; Tsai, I.-Shou; Lu, Huang-Chih; Chuang, Pei-Hsin; Wan, Lei; Lin, Ying-Ju; Lai, Chih-Ho; Lin, Cheng-Wen

    2008-10-01

    Virus isolation and antibody detection are routinely used for diagnosis of Japanese encephalitis virus (JEV) infection, but the low level of transient viremia in some JE patients makes JEV isolation from clinical and surveillance samples very difficult. We describe the use of gold nanoparticle-based RT-PCR and real-time quantitative RT-PCR assays for detection of JEV from its RNA genome. We tested the effect of gold nanoparticles on four different PCR systems, including conventional PCR, reverse-transcription PCR (RT-PCR), and SYBR green real-time PCR and RT-PCR assays for diagnosis in the acute phase of JEV infection. Gold nanoparticles increased the amplification yield of the PCR product and shortened the PCR time compared to the conventional reaction. In addition, nanogold-based real-time RT-PCR showed a linear relationship between Ct and template amount using ten-fold dilutions of JEV. The nanogold-based RT-PCR and real-time quantitative RT-PCR assays were able to detect low levels (1-10 000 copies) of the JEV RNA genomes extracted from culture medium or whole blood, providing early diagnostic tools for the detection of low-level viremia in the acute-phase infection. The assays described here were simple, sensitive, and rapid approaches for detection and quantitation of JEV in tissue cultured samples as well as clinical samples.

  17. Micropallet arrays for the capture, isolation and culture of circulating tumor cells from whole blood of mice engrafted with primary human pancreatic adenocarcinoma.

    PubMed

    Gach, Philip C; Attayek, Peter J; Whittlesey, Rebecca L; Yeh, Jen Jen; Allbritton, Nancy L

    2014-04-15

    Circulating tumor cells (CTCs) are important biomarkers of cancer progression and metastatic potential. The rarity of CTCs in peripheral blood has driven the development of technologies to isolate these tumor cells with high specificity; however, there are limited techniques available for isolating target CTCs following enumeration. A strategy is described to capture and isolate viable tumor cells from whole blood using an array of releasable microstructures termed micropallets. Specific capture of nucleated cells or cells expressing epithelial cell adhesion molecules (EpCAM) was achieved by functionalizing micropallet surfaces with either fibronectin, Matrigel or anti-EpCAM antibody. Surface grafting of poly(acrylic acid) followed by covalent binding of protein A/G enabled efficient capture of EpCAM antibody on the micropallet surface. MCF-7 cells, a human breast adenocarcinoma, were retained on the array surface with 90±8% efficiency when using an anti-EpCAM-coated array. To demonstrate the efficiency of tumor cell retention on micropallet arrays in the presence of blood, MCF-7 cells were mixed into whole blood and added to small arrays (71 mm(2)) coated with fibronectin, Matrigel or anti-EpCAM. These approaches achieved MCF-7 cell capture from ≤10 µL of whole blood with efficiencies greater than 85%. Furthermore, MCF-7 cells intermixed with 1 mL blood and loaded onto large arrays (7171 mm(2)) were captured with high efficiencies (≥97%), could be isolated from the array by a laser-based approach and were demonstrated to yield a high rate of colony formation (≥85%) after removal from the array. Clinical utility of this technology was shown through the capture, isolation and successful culture of CTCs from the blood of mice engrafted with primary human pancreatic tumors. Direct capture and isolation of living tumor cells from blood followed by analysis or culture will be a valuable tool for cancer cell characterization. © 2013 Elsevier B.V. All rights

  18. Blood banking in China.

    PubMed

    Shan, Hua; Wang, Jing-Xing; Ren, Fu-Rong; Zhang, Yuan-Zhi; Zhao, Hai-Yan; Gao, Guo-Jing; Ji, Yang; Ness, Paul M

    2002-11-30

    While transfusion-transmissible diseases, including AIDS and viral hepatitis, continue to spread especially in developing countries, the issue of safeguarding the world's blood supply is of paramount importance. China houses more than 20% of the earth's population, and thus its blood supply has the potential to affect the global community. In recent years, Chinese blood centres have tried to improve the nation's blood safety. Although substantial progress has already been made, many daunting difficulties remain. Traditional cultural barriers need to be overcome to successfully mobilise volunteer blood donors. Gaps in information and technology still need to be closed. Insufficiency of economic resources also restrict the blood bank industry. Other developing countries face many of the same challenges as China.

  19. Relationship between conventional culture and flow cytometry for the diagnosis of urinary tract infection.

    PubMed

    García-Coca, Marta; Gadea, Ignacio; Esteban, Jaime

    2017-06-01

    Urine culture is the gold standard for the diagnosis of urinary tract infections (UTI). The use of flow cytometry analyzers (FCA) prior to culture allows for the quantification and recognition of cell components in urine to be automated and makes it possible to relate these data to the urine pathogens subsequently identified in cultures. Urine samples were assessed with the Sysmex UF-1000i analyzer. Those that met the criteria for culture (> 25 leukocytes/μL or > 385 bacteria/μL) were subjected to quantitative urine culture on chromogenic agar. Counts of red blood cells (RBC), white blood cells (WBC), epithelial cells (EC), and the kind of microorganisms identified in cultures were evaluated. A total of 17,483 samples were processed by FCA. Of these, 9057 met the criteria for culture. Urine cultures were reduced by 48.2%. The most common urine pathogen was Escherichia coli (60.3%). Negative urine cultures were significantly (p < 0.001) associated with a lower WBC count than urine with E. coli, Klebsiella spp. and Proteus spp., but urine with Enterococcus spp. had a lower WBC than negative urine. Contaminated urine had a significantly (p < 0.001) lower WBC than urine with E. coli, Klebsiella spp. and Proteus spp., but no differences were found for Enterococcus spp. (p = 0.729). Negative urine cultures had significantly (p < 0.05) higher EC than all positive urine samples. Contaminated urine was associated (p < 0.001) with higher EC than cultures with E. coli and Klebsiella spp., in comparison with cultures with Enterococcus spp. (p = 0.091) and Proteus spp. (p = 0.251). The use of the Sysmex UF-1000i flow cytometer for screening urine samples allows for a reduction in the number of urine cultures. WBC values correlate well with the main urine pathogens related to UTI. The results observed for Enterococcus spp. suggest a low impact of these pathogens as a cause of UTI.

  20. Michigan's Quantitative School Culture Inventories and Student Achievement

    ERIC Educational Resources Information Center

    McNeece, Alexander A.

    2017-01-01

    Schools must help all students achieve. Leaders who understand the elements of culture and their impact on an organization can be very effective. In 2015, as part of a strategy to cultivate healthy school cultures, the State of Michigan deployed a new self-reporting school culture inventory as part of each school's annual reporting. In this…

  1. Direct identification of bacteria in blood culture by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry: a new methodological approach.

    PubMed

    Kroumova, Vesselina; Gobbato, Elisa; Basso, Elisa; Mucedola, Luca; Giani, Tommaso; Fortina, Giacomo

    2011-08-15

    Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has recently been demonstrated to be a powerful tool for the rapid identification of bacteria from growing colonies. In order to speed up the identification of bacteria, several authors have evaluated the usefulness of this MALDI-TOF MS technology for the direct and quick identification bacteria from positive blood cultures. The results obtained so far have been encouraging but have also shown some limitations, mainly related to the bacterial growth and to the presence of interference substances belonging to the blood cultures. In this paper, we present a new methodological approach that we have developed to overcome these limitations, based mainly on an enrichment of the sample into a growing medium before the extraction process, prior to mass spectrometric analysis. The proposed method shows important advantages for the identification of bacterial strains, yielding an increased identification score, which gives higher confidence in the results. Copyright © 2011 John Wiley & Sons, Ltd.

  2. Image-derived and arterial blood sampled input functions for quantitative PET imaging of the angiotensin II subtype 1 receptor in the kidney

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feng, Tao; Tsui, Benjamin M. W.; Li, Xin

    Purpose: The radioligand {sup 11}C-KR31173 has been introduced for positron emission tomography (PET) imaging of the angiotensin II subtype 1 receptor in the kidney in vivo. To study the biokinetics of {sup 11}C-KR31173 with a compartmental model, the input function is needed. Collection and analysis of arterial blood samples are the established approach to obtain the input function but they are not feasible in patients with renal diseases. The goal of this study was to develop a quantitative technique that can provide an accurate image-derived input function (ID-IF) to replace the conventional invasive arterial sampling and test the method inmore » pigs with the goal of translation into human studies. Methods: The experimental animals were injected with [{sup 11}C]KR31173 and scanned up to 90 min with dynamic PET. Arterial blood samples were collected for the artery derived input function (AD-IF) and used as a gold standard for ID-IF. Before PET, magnetic resonance angiography of the kidneys was obtained to provide the anatomical information required for derivation of the recovery coefficients in the abdominal aorta, a requirement for partial volume correction of the ID-IF. Different image reconstruction methods, filtered back projection (FBP) and ordered subset expectation maximization (OS-EM), were investigated for the best trade-off between bias and variance of the ID-IF. The effects of kidney uptakes on the quantitative accuracy of ID-IF were also studied. Biological variables such as red blood cell binding and radioligand metabolism were also taken into consideration. A single blood sample was used for calibration in the later phase of the input function. Results: In the first 2 min after injection, the OS-EM based ID-IF was found to be biased, and the bias was found to be induced by the kidney uptake. No such bias was found with the FBP based image reconstruction method. However, the OS-EM based image reconstruction was found to reduce variance in the

  3. Kinetic quantitation of cerebral PET-FDG studies without concurrent blood sampling: statistical recovery of the arterial input function.

    PubMed

    O'Sullivan, F; Kirrane, J; Muzi, M; O'Sullivan, J N; Spence, A M; Mankoff, D A; Krohn, K A

    2010-03-01

    Kinetic quantitation of dynamic positron emission tomography (PET) studies via compartmental modeling usually requires the time-course of the radio-tracer concentration in the arterial blood as an arterial input function (AIF). For human and animal imaging applications, significant practical difficulties are associated with direct arterial sampling and as a result there is substantial interest in alternative methods that require no blood sampling at the time of the study. A fixed population template input function derived from prior experience with directly sampled arterial curves is one possibility. Image-based extraction, including requisite adjustment for spillover and recovery, is another approach. The present work considers a hybrid statistical approach based on a penalty formulation in which the information derived from a priori studies is combined in a Bayesian manner with information contained in the sampled image data in order to obtain an input function estimate. The absolute scaling of the input is achieved by an empirical calibration equation involving the injected dose together with the subject's weight, height and gender. The technique is illustrated in the context of (18)F -Fluorodeoxyglucose (FDG) PET studies in humans. A collection of 79 arterially sampled FDG blood curves are used as a basis for a priori characterization of input function variability, including scaling characteristics. Data from a series of 12 dynamic cerebral FDG PET studies in normal subjects are used to evaluate the performance of the penalty-based AIF estimation technique. The focus of evaluations is on quantitation of FDG kinetics over a set of 10 regional brain structures. As well as the new method, a fixed population template AIF and a direct AIF estimate based on segmentation are also considered. Kinetics analyses resulting from these three AIFs are compared with those resulting from radially sampled AIFs. The proposed penalty-based AIF extraction method is found to

  4. A simple and quantitative liquid culture system to measure megakaryocyte growth using highly purified CFU-MK.

    PubMed

    Miyazaki, H; Horie, K; Shimada, Y; Kokubo, A; Maeda, E; Inoue, H; Kato, T

    1995-10-01

    A new and quantitative liquid culture system has been developed to measure the production of megakaryocytes from megakaryocyte progenitor cells (colony-forming units-megakaryocyte [CFU-MK]). The system uses as a target population a glycoprotein (Gp) IIb/IIIa+ subpopulation of rat bone marrow cells previously demonstrated to be highly enriched for CFU-MK. GpIIb/IIIa+ cells were cultured at 5 x 10(4) cells/mL (10(4) cells/well) with test samples in 96-well tissue culture plates for 4 days at 37 degrees C. During the final 3 hours of incubation, the cells were pulsed with [14C]5-hydroxytryptamine creatinine sulfate (14C-serotonin). After incubation, the plates were washed and the cell pellets were lysed with Triton-X 100. The cell lysate was infiltrated into a commercially available solid scintillator and dried, and radioactivity was measured. In this assay system, rat interleukin-3 (IL-3) was found to be the most potent among known cytokines tested. Murine granulocyte-macrophage colony-stimulating factor (GM-CSF), human erythropoietin (Epo), human IL-6, and murine stem cell factor (SCF) each alone stimulated megakaryocyte growth but were much less active than rat IL-3. Plasma of rats rendered thrombocytopenic by injection of monoclonal antirat platelet GpIIb/IIIa antibody exhibited significant activity, and the active protein fractions partially purified from the plasma showed much higher activity, but normal rat plasma had no effect. This liquid culture system allows the measurement of a large number of test samples--including a wide variety of cytokines and unknown growth factors, alone or in combinations--and provides a simple method for evaluating the early proliferative events involving CFU-MK in the megakaryocyte differentiation pathway.

  5. Methodology for determining major constituents of ayahuasca and their metabolites in blood.

    PubMed

    McIlhenny, Ethan H; Riba, Jordi; Barbanoj, Manel J; Strassman, Rick; Barker, Steven A

    2012-03-01

    There is an increasing interest in potential medical applications of ayahuasca, a South American psychotropic plant tea with a long cultural history of indigenous medical and religious use. Clinical research into ayahuasca will require specific, sensitive and comprehensive methods for the characterization and quantitation of these compounds and their metabolites in blood. A combination of two analytical techniques (high-performance liquid chromatography with ultraviolet and/or fluorescence detection and gas chromatography with nitrogen-phosphorus detection) has been used for the analysis of some of the constituents of ayahuasca in blood following its oral consumption. We report here a single methodology for the direct analysis of 14 of the major alkaloid components of ayahuasca, including several known and potential metabolites of N,N-dimethyltryptamine and the harmala alkaloids in blood. The method uses 96-well plate/protein precipitation/filtration for plasma samples, and analysis by HPLC-ion trap-ion trap-mass spectrometry using heated electrospray ionization to reduce matrix effects. The method expands the list of compounds capable of being monitored in blood following ayahuasca administration while providing a simplified approach to their analysis. The method has adequate sensitivity, specificity and reproducibility to make it useful for clinical research with ayahuasca. Copyright © 2011 John Wiley & Sons, Ltd.

  6. Direct identification from positive blood broth culture by matrix-assisted laser desorption-ionization time-of-flight mass spectrometry (MALDI-TOF MS).

    PubMed

    Barberino, Maria Goreth; Silva, Marcio de Oliveira; Arraes, Ana Carolina Palmeiras; Correia, Luís Cláudio; Mendes, Ana Verena

    Bloodstream infections (BSIs) are among the most concerning bacterial infections. They are one of the leading causes of morbidity and mortality, and occur in 30-70% of critical care patients. The prompt identification of the causative microorganism can help choosing the appropriate antimicrobial therapy that will lead to better clinical outcomes. Blood culture is one of the most relevant tests for microbiological diagnosis of bacterial infections. The introduction of the MALDI-TOF microbiological diagnosis significantly decreased the time of identifying microorganisms. However, it depends on the growth on solid culture medium. In this study, 538 bottles of positive blood cultures were evaluated to test the accuracy of an in house modified protocol. The study sample consisted of 198 Gram-negative and 350 Gram-positive bacteria. In all, 460 (83.94%) species were identified based on the direct plate findings. The protocol allowed the identification of 185/198 (93.43%) of the Gram-negative bacteria, including aerobes, anaerobes, and non-fermenters, and 275/350 (78.85%) of the Gram-positive bacteria. The proposed method has the potential to provide accurate results in comparison to the traditional method with the potential to reduce the turnaround time for the results and optimize antimicrobial therapy in BSI. Copyright © 2017 Sociedade Brasileira de Infectologia. Published by Elsevier Editora Ltda. All rights reserved.

  7. Cardiac and peripheral blood similarities in the comparison of nordiazepam and bromazepam blood concentrations.

    PubMed

    Pos Pok, P-Rop; Haddouche, Djamel; Mauras, Michel; Kuhlmann, Erika; Burle, Joëlle; Salmon, Thierry; Berland, Emilie; Coiffait, P-Emmanuel; Viala, Alain

    2008-01-01

    Concomitant heart and peripheral blood determinations were performed on 40 fatal cases involving nordiazepam (20 cases) and bromazepam (20 cases). The heart blood concentration for the two drugs (588 ng/mL for nordiazepam and 802 ng/mL for bromazepam) does not differ from the corresponding peripheral blood concentration (587 ng/mL for nordiazepam and 883 ng/mL for bromazepam). The mean ratios for the heart and peripheral blood concentrations were 0.95 for nordiazepam and 0.86 for bromazepam. No postmortem redistribution was observed for these two benzodiazepines. The authors thus suggest that corresponding heart blood can be proposed in the quantitative analysis of these drugs when peripheral blood is unavailable. The present study also shows the stability of the two drugs after a year of storage.

  8. Quantitative lung perfusion evaluation using Fourier decomposition perfusion MRI.

    PubMed

    Kjørstad, Åsmund; Corteville, Dominique M R; Fischer, Andre; Henzler, Thomas; Schmid-Bindert, Gerald; Zöllner, Frank G; Schad, Lothar R

    2014-08-01

    To quantitatively evaluate lung perfusion using Fourier decomposition perfusion MRI. The Fourier decomposition (FD) method is a noninvasive method for assessing ventilation- and perfusion-related information in the lungs, where the perfusion maps in particular have shown promise for clinical use. However, the perfusion maps are nonquantitative and dimensionless, making follow-ups and direct comparisons between patients difficult. We present an approach to obtain physically meaningful and quantifiable perfusion maps using the FD method. The standard FD perfusion images are quantified by comparing the partially blood-filled pixels in the lung parenchyma with the fully blood-filled pixels in the aorta. The percentage of blood in a pixel is then combined with the temporal information, yielding quantitative blood flow values. The values of 10 healthy volunteers are compared with SEEPAGE measurements which have shown high consistency with dynamic contrast enhanced-MRI. All pulmonary blood flow (PBF) values are within the expected range. The two methods are in good agreement (mean difference = 0.2 mL/min/100 mL, mean absolute difference = 11 mL/min/100 mL, mean PBF-FD = 150 mL/min/100 mL, mean PBF-SEEPAGE = 151 mL/min/100 mL). The Bland-Altman plot shows a good spread of values, indicating no systematic bias between the methods. Quantitative lung perfusion can be obtained using the Fourier Decomposition method combined with a small amount of postprocessing. Copyright © 2013 Wiley Periodicals, Inc.

  9. [Improved method of studying the blood for sterility].

    PubMed

    Talapa, A I

    1983-05-01

    The technique used for the inoculation and subculturing of blood samples in testing them for sterility is described. This technique eliminates the possibility of contaminating the culture medium and the blood sample under test with extraneous bacterial flora. Blood samples were inoculated without opening the containers with the culture medium. Inoculation was made with the syringe and the needle used for taking the blood sample through the punctured rubber stopper closing the container. Subculturing on solid culture media was also carried out without opening the containers: the rubber stopper was punctured and the contents of the container withdrawn with a pipette needle. The use of this new technique made it possible to detect bacteremia in 12.8% of cases, only in persons with purulent and septic diseases, whereas by using the existing technique bacteremia was detected both in sick and healthy persons, in 38.6% and 26.6% of cases, respectively.

  10. Histamine Induces Alzheimer's Disease-Like Blood Brain Barrier Breach and Local Cellular Responses in Mouse Brain Organotypic Cultures

    PubMed Central

    Sedeyn, Jonathan C.; Wu, Hao; Hobbs, Reilly D.; Levin, Eli C.; Nagele, Robert G.; Venkataraman, Venkat

    2015-01-01

    Among the top ten causes of death in the United States, Alzheimer's disease (AD) is the only one that cannot be cured, prevented, or even slowed down at present. Significant efforts have been exerted in generating model systems to delineate the mechanism as well as establishing platforms for drug screening. In this study, a promising candidate model utilizing primary mouse brain organotypic (MBO) cultures is reported. For the first time, we have demonstrated that the MBO cultures exhibit increased blood brain barrier (BBB) permeability as shown by IgG leakage into the brain parenchyma, astrocyte activation as evidenced by increased expression of glial fibrillary acidic protein (GFAP), and neuronal damage-response as suggested by increased vimentin-positive neurons occur upon histamine treatment. Identical responses—a breakdown of the BBB, astrocyte activation, and neuronal expression of vimentin—were then demonstrated in brains from AD patients compared to age-matched controls, consistent with other reports. Thus, the histamine-treated MBO culture system may provide a valuable tool in combating AD. PMID:26697497

  11. Superiority of SDS lysis over saponin lysis for direct bacterial identification from positive blood culture bottle by MALDI-TOF MS.

    PubMed

    Caspar, Yvan; Garnaud, Cécile; Raykova, Mariya; Bailly, Sébastien; Bidart, Marie; Maubon, Danièle

    2017-05-01

    Fast species diagnosis has an important health care impact, as rapid and specific antibacterial therapy is of clear benefit for patient's outcome. Here, a new protocol for species identification directly from positive blood cultures is proposed. Four in-house protocols for bacterial identification by MS directly from clinical positive blood cultures evaluating two lytic agents, SDS and saponin, and two protein extraction schemes, fast (FP) and long (LP) are compared. One hundred and sixty-eight identification tests are carried out on 42 strains. Overall, there are correct identifications to the species level in 90% samples for the SDS-LP, 60% for the SDS-FP, 48% for the saponin LP, and 43% for the saponin FP. Adapted scores allowed 92, 86, 72, and 53% identification for SDS-LP, SDS-FP, saponin LP, and saponin FP, respectively. Saponin lysis is associated with a significantly lower score compared to SDS (0.87 [0.83-0.92], p-value < 0.001). This study supports the use of SDS lysis instead of saponin lysis and the application of this rapid and cost-effective protocol in daily routine for microbiological agents implicated in septicemia. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Red Blood Cell Agglutination for Blood Typing Within Passive Microfluidic Biochips.

    PubMed

    Huet, Maxime; Cubizolles, Myriam; Buhot, Arnaud

    2018-04-19

    Pre-transfusion bedside compatibility test is mandatory to check that the donor and the recipient present compatible groups before any transfusion is performed. Although blood typing devices are present on the market, they still suffer from various drawbacks, like results that are based on naked-eye observation or difficulties in blood handling and process automation. In this study, we addressed the development of a red blood cells (RBC) agglutination assay for point-of-care blood typing. An injection molded microfluidic chip that is designed to enhance capillary flow contained anti-A or anti-B dried reagents inside its microchannel. The only blood handling step in the assay protocol consisted in the deposit of a blood drop at the tip of the biochip, and imaging was then achieved. The embedded reagents were able to trigger RBC agglutination in situ, allowing for us to monitor in real time the whole process. An image processing algorithm was developed on diluted bloods to compute real-time agglutination indicator and was further validated on undiluted blood. Through this proof of concept, we achieved efficient, automated, real time, and quantitative measurement of agglutination inside a passive biochip for blood typing which could be further generalized to blood biomarker detection and quantification.

  13. Inner Blood-Retinal Barrier Dominantly Expresses Breast Cancer Resistance Protein: Comparative Quantitative Targeted Absolute Proteomics Study of CNS Barriers in Pig.

    PubMed

    Zhang, Zhengyu; Uchida, Yasuo; Hirano, Satoshi; Ando, Daisuke; Kubo, Yoshiyuki; Auriola, Seppo; Akanuma, Shin-Ichi; Hosoya, Ken-Ichi; Urtti, Arto; Terasaki, Tetsuya; Tachikawa, Masanori

    2017-11-06

    The purpose of this study was to determine absolute protein expression levels of transporters at the porcine inner blood-retinal barrier (BRB) and to compare the transporter protein expression quantitatively among the inner BRB, outer BRB, blood-brain barrier (BBB), and blood-cerebrospinal fluid barrier (BCSFB). Crude membrane fractions of isolated retinal capillaries (inner BRB) and isolated retinal pigment epithelium (RPE, outer BRB) were prepared from porcine eyeballs, while plasma membrane fractions were prepared from isolated porcine brain capillaries (BBB) and isolated choroid plexus (BCSFB). Protein expression levels of 32 molecules, including 16 ATP-binding-cassette (ABC) transporters and 13 solute-carrier (SLC) transporters, were measured using a quantitative targeted absolute proteomic technique. At the inner BRB, five molecules were detected: breast cancer resistance protein (BCRP, ABCG2; 22.8 fmol/μg protein), multidrug resistance protein 1 (MDR1, ABCB1; 8.70 fmol/μg protein), monocarboxylate transporter 1 (MCT1, SLC16A1; 4.83 fmol/μg protein), glucose transporter 1 (GLUT1, SLC2A1; 168 fmol/μg protein), and sodium-potassium adenosine triphosphatase (Na + /K + -ATPase; 53.7 fmol/μg protein). Other proteins were under the limits of quantification. Expression of MCT1 was at least 17.6-, 11.0-, and 19.2-fold greater than those of MCT2, 3, and 4, respectively. The transporter protein expression at the inner BRB was most highly correlated with that at the BBB (R 2 = 0.8906), followed by outer BRB (R 2 = 0.7988) and BCSFB (R 2 = 0.4730). Sodium-dependent multivitamin transporter (SMVT, SLC5A6) and multidrug resistance-associated protein 1 (MRP1, ABCC1) were expressed at the outer BRB (0.378 and 1.03 fmol/μg protein, respectively) but were under the limit of quantification at the inner BRB. These findings may be helpful for understanding differential barrier function.

  14. Automated Interpretation of Blood Culture Gram Stains by Use of a Deep Convolutional Neural Network.

    PubMed

    Smith, Kenneth P; Kang, Anthony D; Kirby, James E

    2018-03-01

    Microscopic interpretation of stained smears is one of the most operator-dependent and time-intensive activities in the clinical microbiology laboratory. Here, we investigated application of an automated image acquisition and convolutional neural network (CNN)-based approach for automated Gram stain classification. Using an automated microscopy platform, uncoverslipped slides were scanned with a 40× dry objective, generating images of sufficient resolution for interpretation. We collected 25,488 images from positive blood culture Gram stains prepared during routine clinical workup. These images were used to generate 100,213 crops containing Gram-positive cocci in clusters, Gram-positive cocci in chains/pairs, Gram-negative rods, or background (no cells). These categories were targeted for proof-of-concept development as they are associated with the majority of bloodstream infections. Our CNN model achieved a classification accuracy of 94.9% on a test set of image crops. Receiver operating characteristic (ROC) curve analysis indicated a robust ability to differentiate between categories with an area under the curve of >0.98 for each. After training and validation, we applied the classification algorithm to new images collected from 189 whole slides without human intervention. Sensitivity and specificity were 98.4% and 75.0% for Gram-positive cocci in chains and pairs, 93.2% and 97.2% for Gram-positive cocci in clusters, and 96.3% and 98.1% for Gram-negative rods. Taken together, our data support a proof of concept for a fully automated classification methodology for blood-culture Gram stains. Importantly, the algorithm was highly adept at identifying image crops with organisms and could be used to present prescreened, classified crops to technologists to accelerate smear review. This concept could potentially be extended to all Gram stain interpretive activities in the clinical laboratory. Copyright © 2018 American Society for Microbiology.

  15. A comparative study of Widal test with blood culture in the diagnosis of typhoid fever in febrile patients.

    PubMed

    Andualem, Gizachew; Abebe, Tamrat; Kebede, Nigatu; Gebre-Selassie, Solomon; Mihret, Adane; Alemayehu, Haile

    2014-09-17

    Typhoid fever is a major health problem in developing countries and its diagnosis on clinical ground is difficult. Diagnosis in developing countries including Ethiopia is mostly done by Widal test. However, the value of the test has been debated. Hence, evaluating the result of this test is necessary for correct interpretation of the result. The main aim of this study was to compare the result of Widal test and blood culture in the diagnosis of typhoid fever in febrile patients. Blood samples were collected from 270 febrile patients with symptoms clinically similar to typhoid fever and visiting St. Paul's General Specialized Hospitals from mid December 2010 to March 2011. Blood culture was used to isolate S.typhi and S.paratyphi. Slide agglutination test and tube agglutination tests were used for the determination of antibody titer. An antibody titer of ≥1:80 for anti TO and ≥1:160 for anti TH were taken as a cut of value to indicate recent infection of typhoid fever. One hundred and eighty six (68.9%) participants were females and eighty four (31.1%) were males. 7 (2.6%) cases of S. typhi and 4 (1.5%) cases of S. paratyphi were identified with the total prevalence of typhoid fever 4.1%. The total number of patients who have indicative of recent infection by either of O and H antigens Widal test is 88 (32.6%). The sensitivity, specificity, Positive predictive Value and Negative predictive Value of Widal test were 71.4%, 68.44%, 5.7% and 98.9% respectively. Widal test has a low sensitivity, specificity and PPV, but it has good NPV which indicates that negative Widal test result have a good indication for the absence of the disease.

  16. Quantitative measurement of cerebral blood flow in a juvenile porcine model by depth-resolved near-infrared spectroscopy

    NASA Astrophysics Data System (ADS)

    Elliott, Jonathan T.; Diop, Mamadou; Tichauer, Kenneth M.; Lee, Ting-Yim; Lawrence, Keith St.

    2010-05-01

    Nearly half a million children and young adults are affected by traumatic brain injury each year in the United States. Although adequate cerebral blood flow (CBF) is essential to recovery, complications that disrupt blood flow to the brain and exacerbate neurological injury often go undetected because no adequate bedside measure of CBF exists. In this study we validate a depth-resolved, near-infrared spectroscopy (NIRS) technique that provides quantitative CBF measurement despite significant signal contamination from skull and scalp tissue. The respiration rates of eight anesthetized pigs (weight: 16.2+/-0.5 kg, age: 1 to 2 months old) are modulated to achieve a range of CBF levels. Concomitant CBF measurements are performed with NIRS and CT perfusion. A significant correlation between CBF measurements from the two techniques is demonstrated (r2=0.714, slope=0.92, p<0.001), and the bias between the two techniques is -2.83 mL.min-1.100 g-1 (CI0.95: -19.63 mL.min-1.100 g-1-13.9 mL.min-1.100 g-1). This study demonstrates that accurate measurements of CBF can be achieved with depth-resolved NIRS despite significant signal contamination from scalp and skull. The ability to measure CBF at the bedside provides a means of detecting, and thereby preventing, secondary ischemia during neurointensive care.

  17. Cross-cultural differences in parental beliefs about infant motor development: A quantitative and qualitative report of middle-class Israeli and Dutch parents.

    PubMed

    van Schaik, Saskia D M; Oudgenoeg-Paz, Ora; Atun-Einy, Osnat

    2018-06-01

    The present study explored cultural differences in parental beliefs about motor development across 2 Western cultures: Israel and the Netherlands. Can 2 cultural models be distinguished regarding infant motor development in Israel and the Netherlands or are parental beliefs about motor development similar across these cultures? Using a questionnaire containing closed and open questions, beliefs of 206 Israeli and 198 Dutch parents of first-born children between 2 and 7 months old were analyzed. Based on both quantitative and qualitative analyses, distinct cultural models were found showing that the Dutch attributed a bigger role to maturation and children's own pace than to stimulation. The Israeli parents found stimulation of motor development important and discussed active stimulation more elaborately. When discussing supportive activities, the Israeli parents mentioned specific activities, whereas the Dutch parents used more general, vague expressions about support. Moreover, the Israeli parents discussed the need for expert advice and advice from relatives and other parents more than the Dutch parents, who rely on their own observations, books, or websites more often. The cultural background was the strongest predictor of parental beliefs about motor development. Parental education, age, children's birth weight, gender, and having seen a physical therapist showed weaker relations with parental beliefs. Altogether, 2 distinguishing cultural models can be found, raising the question whether infant motor development can be approached similarly across Western cultures. Besides this implication for science, practitioners should also be aware of differences between cultures and between parents. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  18. Contaminants in blood cultures: importance, implications, interpretation and prevention.

    PubMed

    Dargère, S; Cormier, H; Verdon, R

    2018-04-03

    Despite the development of new microbiologic technologies, blood cultures (BCs) remain the first-line tool for the diagnosis of bloodstream infections. Their diagnostic value may be affected when a microorganism of questionable evidence is isolated-for example, coagulase-negative staphylococci, Bacillus spp., viridans group streptococci, Corynebacterium spp., Propionibacterium spp. and Micrococcus spp. Finally, making a correct diagnosis of pathogenicity (vs. contamination) is challenging. To review the current ways of dealing with the problem of BC contaminants (BCCs) and to provide practical suggestions to decrease BCC rates. PubMed electronic databases and existing reviews were searched up to December 2017 to retrieve relevant publications related to the topic. This review describes the burden of BCC and analyses the main current issues and controversies in interpreting the occurrence of potential BC contaminants. It focuses on the best-described approaches to decide whether BCC is present and discusses the different strategies of prevention in adults. Each institution should have an efficient policy to prevent BCC, emphasizing the importance of following guidelines for prescribing and collecting BCs. Training healthcare workers should focus on detrimental influence on patient care and highlight the work and costs due to contaminants. The accurate differentiation of a contaminant from a true pathogen relies on a multidisciplinary approach and the clinical judgement of experienced practitioners. Copyright © 2018 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  19. Nonsteroidal anti-inflammatory drugs increase TNF production in rheumatoid synovial membrane cultures and whole blood.

    PubMed

    Page, Theresa H; Turner, Jeremy J O; Brown, Anthony C; Timms, Emma M; Inglis, Julia J; Brennan, Fionula M; Foxwell, Brian M J; Ray, Keith P; Feldmann, Marc

    2010-09-15

    Nonsteroidal anti-inflammatory drugs (NSAIDs) inhibit cyclooxygenase activity and hence PG production. However, the ability of NSAIDs to ameliorate pain and tenderness does not prevent disease progression in rheumatoid arthritis, a disease whose pathogenesis is linked to the presence of proinflammatory cytokines, such as TNF-alpha. To understand this observation, we have examined the effect of NSAIDs on the production of clinically validated proinflammatory cytokines. We show that a variety of NSAIDs superinduce production of TNF from human peripheral blood monocytes and rheumatoid synovial membrane cultures. A randomized, double-blinded, crossover, placebo-controlled trial in healthy human volunteers also revealed that the NSAID drug celecoxib increased LPS-induced TNF production in whole blood. NSAID-mediated increases in TNF are reversed by either the addition of exogenous PGE(2) or by a PGE(2) EP2 receptor agonist, revealing that PGE(2) signaling via its EP2 receptor provides a valuable mechanism for controlling excess TNF production. Thus, by reducing the level of PGE(2), NSAIDs can increase TNF production and may exacerbate the proinflammatory environment both within the rheumatoid arthritis joint and the systemic environment.

  20. Evaluation of BD MAX Staph SR Assay for Differentiating Between Staphylococcus aureus and Coagulase-Negative Staphylococci and Determining Methicillin Resistance Directly From Positive Blood Cultures.

    PubMed

    Lee, Jaewoong; Park, Yeon Joon; Park, Dong Jin; Park, Kang Gyun; Lee, Hae Kyung

    2017-01-01

    We evaluated the performance of the BD MAX StaphSR Assay (SR assay; BD, USA) for direct detection of Staphylococcus aureus and methicillin resistance not only in S. aureus but also in coagulase-negative Staphylococci (CNS) from positive blood cultures. From 228 blood culture bottles, 103 S. aureus [45 methicillin-resistant S. aureus (MRSA), 55 methicillin-susceptible S. aureus (MSSA), 3 mixed infections (1 MRSA+Enterococcus faecalis, 1 MSSA+MRCNS, 1 MSSA+MSCNS)], and 125 CNS (102 MRCNS, 23 MSCNS) were identified by Vitek 2. For further analysis, we obtained the cycle threshold (Ct) values from the BD MAX system software to determine an appropriate cutoff value. For discrepancy analysis, conventional mecA/mecC PCR and oxacillin minimum inhibitory concentrations (MICs) were determined. Compared to Vitek 2, the SR assay identified all 103 S. aureus isolates correctly but failed to detect methicillin resistance in three MRSA isolates. All 55 MSSA isolates were correctly identified by the SR assay. In the concordant cases, the highest Ct values for nuc, mecA, and mec right-extremity junction (MREJ) were 25.6, 22, and 22.2, respectively. Therefore, we selected Ct values from 0-27 as a range of positivity, and applying this cutoff, the sensitivity/specificity of the SR assay were 100%/100% for detecting S. aureus, and 97.9%/98.1% and 99.0%/95.8% for detecting methicillin resistance in S. aureus and CNS, respectively. We propose a Ct cutoff value for nuc/mec assay without considering MREJ because mixed cultures of MSSA and MRCNS were very rare (0.4%) in the positive blood cultures.