Sample records for quantitative coronary angiographic

  1. Advanced 2-dimensional quantitative coronary angiographic analysis for prediction of fractional flow reserve in intermediate coronary stenoses.

    PubMed

    Opolski, Maksymilian P; Pregowski, Jerzy; Kruk, Mariusz; Kepka, Cezary; Staruch, Adam D; Witkowski, Adam

    2014-07-01

    The widespread clinical application of coronary computed tomography angiography (CCTA) has resulted in increased referral patterns of patients with intermediate coronary stenoses to invasive coronary angiography. We evaluated the application of advanced quantitative coronary angiography (A-QCA) for predicting fractional flow reserve (FFR) in intermediate coronary lesions detected on CCTA. Fifty-six patients with 66 single intermediate coronary lesions (≥ 50% to 80% stenosis) on CCTA prospectively underwent coronary angiography and FFR. A-QCA including calculation of the Poiseuille-based index defined as the ratio of lesion length to the fourth power of the minimal lumen diameter (MLD) was performed. Significant stenosis was defined as FFR ≤ 0.80. The mean FFR was 0.86 ± 0.09, and 18 lesions (27%) were functionally significant. FFR correlated with lesion length (R=-0.303, P=0.013), MLD (R=0.527, P<0.001), diameter stenosis (R=-0.404, P=0.001), minimum lumen area (MLA) (R=0.530, P<0.001), lumen stenosis (R=-0.400, P=0.001), and Poiseuille-based index (R=-0.602, P<0.001). The optimal cutoff values for MLD, MLA, diameter stenosis, and lumen stenosis were ≤ 1.3 mm, ≤ 1.5 mm, >44%, and >69%, respectively (maximum negative predictive value of 94% for MLA, maximum positive predictive value of 58% for diameter stenosis). The Poiseuille-based index was the most accurate (C statistic 0.86, sensitivity 100%, specificity 71%, positive predictive value 56%, and negative predictive value 100%) predictor of FFR ≤ 0.80, but showed the lowest interobserver agreement (intraclass correlation coefficient 0.37). A-QCA might be used to rule out significant ischemia in intermediate stenoses detected by CCTA. The diagnostic application of the Poiseuille-based angiographic index is precluded by its high interobserver variability.

  2. Angiographic prevalence and pattern of coronary artery disease in women.

    PubMed

    Ezhumalai, Babu; Jayaraman, Balachander

    2014-01-01

    There are not many studies describing the prevalence and pattern of "coronary artery disease" (CAD) in women undergoing "coronary angiography" (CAG). Hence, uncertainty thrives with regard to the angiographic prevalence and pattern of CAD in women. Our objective was to study the prevalence and pattern of CAD among women undergoing CAG. Data of 500 women who underwent CAG for suspected CAD over 3 years were retrospectively analyzed. They were classified into young group (age < 55 years) and elderly group (age ≥ 55 years). Angiographic profile of "left main disease" (LMD) was also studied. There was greater prevalence of obstructive CAD especially double vessel disease and triple vessel disease in elderly group while normal coronaries were more prevalent in young group. There was equal distribution of non-significant lesions and intermediate lesions between the two groups. The prevalence of LMD is 3.4%, obstructive CAD is 45.4%, and multivessel disease is 28%. The prevalence of LMD and multivessel disease is 31.4%. The pattern of involvement of coronary arteries was same between the two groups; left anterior descending artery is the most commonly affected vessel. Chronic total occlusion mostly involved right coronary artery. Bifurcation lesion involving distal left main coronary artery is the most prevalent pattern of LMD. There has been a change with regard to clinical presentation and onset of risk factors for CAD at young age, but the load of atherosclerotic burden and pattern of involvement of coronary arteries have not changed in women. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  3. Family history does not predict angiographic localization or severity of coronary artery disease.

    PubMed

    Banerjee, Amitava; Lim, Chris C S; Silver, Louise E; Heneghan, Carl; Welch, Sarah J V; Mehta, Ziyah; Banning, Adrian P; Rothwell, Peter M

    2012-04-01

    Family history of MI is an established risk factor for coronary artery disease and subclinical atherosclerosis. Maternal MI and maternal stroke are more common in females than males presenting with acute coronary syndromes (ACS), suggesting sex-specific heritability, but the effects of family history on location and extent of coronary artery disease are unknown. In a prospective, population-based study (Oxford Vascular Study) of all patients with ACS, family history data for stroke and MI were analysed by sex of proband and affected first degree relatives (FDRs), and coronary angiograms were reviewed, where available. Of 835 probands with one or more ACS, 623 (420 males) had incident events and complete family history data. 351 patients with incident events (56.3%; 266 males) underwent coronary angiography. Neither angiographic disease localization nor severity were associated with sex-of-parent/sex-of-offspring in men or women. Sex-specific family history data do not predict angiographic localization of coronary disease in patients presenting with ACS. Maternal stroke and maternal MI probably affect ACS in females by a mechanism unrelated to atherosclerosis or coronary anatomy. However, family history data may still be useful in risk prediction and prognosis of ACS. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  4. An angiographic technique for coronary fractional flow reserve measurement: in vivo validation.

    PubMed

    Takarada, Shigeho; Zhang, Zhang; Molloi, Sabee

    2013-03-01

    Fractional flow reserve (FFR) is an important prognostic determinant in a clinical setting. However, its measurement currently requires the use of invasive pressure wire, while an angiographic technique based on first-pass distribution analysis and scaling laws can be used to measure FFR using only image data. Eight anesthetized swine were instrumented with flow probe on the proximal segment of the left anterior descending (LAD) coronary arteries. Volumetric blood flow from the flow probe (Qp), coronary pressure (Pa) and right atrium pressure (Pv) were continuously recorded. Flow probe-based FFR (FFRq) was measured from the ratio of flow with and without stenosis. To determine the angiography-based FFR (FFRa), the ratio of blood flow in the presence of a stenosis (QS) to theoretically normal blood flow (QN) was calculated. A region of interest in the LAD arterial bed was drawn to generate time-density curves using angiographic images. QS was measured using a time-density curve and the assumption that blood was momentarily replaced with contrast agent during the injection. QN was estimated from the total coronary arterial volume using scaling laws. Pressure-wire measurements of FFR (FFRp), which was calculated from the ratio of distal coronary pressure (Pd) divided by proximal pressure (Pa), were continuously obtained during the study. A total of 54 measurements of FFRa, FFRp, and FFRq were taken. FFRa showed a good correlation with FFRq (FFRa = 0.97 FFRq +0.06, r(2) = 0.80, p < 0.001), although FFRp overestimated the FFRq (FFRp = 0.657 FFRq + 0.313, r(2) = 0.710, p < 0.0001). Additionally, the Bland-Altman analysis showed a close agreement between FFRa and FFRq. This angiographic technique to measure FFR can potentially be used to evaluate both anatomical and physiological assessments of a coronary stenosis during routine diagnostic cardiac catheterization that requires no pressure wires.

  5. Validation of a new UNIX-based quantitative coronary angiographic system for the measurement of coronary artery lesions.

    PubMed

    Bell, M R; Britson, P J; Chu, A; Holmes, D R; Bresnahan, J F; Schwartz, R S

    1997-01-01

    We describe a method of validation of computerized quantitative coronary arteriography and report the results of a new UNIX-based quantitative coronary arteriography software program developed for rapid on-line (digital) and off-line (digital or cinefilm) analysis. The UNIX operating system is widely available in computer systems using very fast processors and has excellent graphics capabilities. The system is potentially compatible with any cardiac digital x-ray system for on-line analysis and has been designed to incorporate an integrated database, have on-line and immediate recall capabilities, and provide digital access to all data. The accuracy (mean signed differences of the observed minus the true dimensions) and precision (pooled standard deviations of the measurements) of the program were determined x-ray vessel phantoms. Intra- and interobserver variabilities were assessed from in vivo studies during routine clinical coronary arteriography. Precision from the x-ray phantom studies (6-In. field of view) for digital images was 0.066 mm and for digitized cine images was 0.060 mm. Accuracy was 0.076 mm (overestimation) for digital images compared to 0.008 mm for digitized cine images. Diagnostic coronary catheters were also used for calibration; accuracy.varied according to size of catheter and whether or not they were filled with iodinated contrast. Intra- and interobserver variabilities were excellent and indicated that coronary lesion measurements were relatively user-independent. Thus, this easy to use and very fast UNIX based program appears to be robust with optimal accuracy and precision for clinical and research applications.

  6. Angiographic predictors of 3-year patency of bypass grafts implanted on the right coronary artery system: a prospective randomized comparison of gastroepiploic artery, saphenous vein, and right internal thoracic artery grafts.

    PubMed

    Glineur, David; D'hoore, William; de Kerchove, Laurent; Noirhomme, Philippe; Price, Joel; Hanet, Claude; El Khoury, Gebrine

    2011-11-01

    Saphenous vein, in situ right gastroepiploic artery, and right internal thoracic artery grafts are routinely used to revascularize the right coronary artery. Little is known about the predictive value of objective preoperative angiographic parameters on midterm graft patency. We prospectively enrolled 210 consecutive patients undergoing coronary revascularization. Revascularization of the right coronary artery was randomly performed with the saphenous vein grafts in 81 patients and the right gastroepiploic artery in 92 patients. During the same study period, 37 patients received right coronary artery revascularization with the right internal thoracic artery used in a Y-composite fashion. All patients underwent a protocol-driven coronary angiogram 3 years after surgery. Preoperative angiographic parameters included minimum lumen diameter percent stenosis measured by quantitative angiography. A graft was considered "not functional" with patency scores of 0 to 2 and "functional" with patency scores of 3 or 4. Angiographic follow-up was 100% complete. A significant difference in the distribution of flow patterns was observed in the 3 groups. In multivariate analysis, the use of a saphenous vein graft was associated with superior graft functionality compared with the other conduits (odds ratio, 6.1; 95% confidence interval, 2.4-15). Graft function was negatively influenced by the minimum lumen diameter (odds ratio, 0.11; confidence interval, 0.05-0.25). In the right gastroepiploic artery and right internal thoracic artery groups, the proportion of functional grafts was higher when the minimum lumen diameter was below a threshold value in the third minimum lumen diameter quartile (0.64-1.30 mm). Preoperative angiography predicts graft patency in the right gastroepiploic artery and right internal thoracic artery, whereas the flow pattern in saphenous vein grafts is significantly less influenced by quantitative angiographic parameters. Copyright © 2011 The American

  7. Coronary risk factors of angiographically assessed patients from Syria.

    PubMed

    al-Kateb, H; Zarzzour, W; Shameah, M; Juoma, M

    1998-02-01

    Predictors of coronary artery disease in an Arab population had not been defined well. We studied 192 male patients with suspected coronary artery disease, who underwent catheterization. We defined definite coronary artery disease as > 50% stenosis in any of three vessels. The effects of age, obesity, smoking, hypertension, diabetes, and lipid fractions were assessed by means of univariate and multivariate regression analysis. Coronary artery disease was present in 153 men (80%) and absent from 39 men. Patients without coronary artery disease were slightly younger, thinner, smoked less, and had lower cholesterol, low-density lipoprotein cholesterol, and apolipoprotein B levels than did those who had coronary artery disease. By stepwise regression analysis, the best discriminators were body mass index (P = 0.0004), age (P = 0.0005), smoking (P = 0.014) and the apolipoprotein B:A-I ratio (P = 0.041). The strongest Pearson correlation coefficients for coronary artery disease were the ratio of total: high-density lipoprotein cholesterol levels (r = 0.26), the apolipoprotein B:A-I ratio (r = 0.26), and age (r = 0.25), all P < 0.0005. In this angiographically evaluated Syrian population, previously recognized, well-known risk factors appeared. Obesity, smoking, hypertension, diabetes, and elevated lipid levels are all amenable to correction. Syria should adopt the same secondary prevention strategies as those currently being practiced by non-Arab countries.

  8. Correlation of C-Reactive Protein and Cardiac Enzymes with Angiographic Severity of Coronary Artery Disease in Pakistani Patients with Acute Coronary Syndrome.

    PubMed

    Saleem, Ayesha; Ali, Azmat

    2017-02-01

    To determine the correlation of C-reactive protein (CRP) levels with the severity of coronary stenosis on angiography and the association of cardiac enzymes with the degree of stenosis in acute coronary syndrome (ACS) patients. Secondly, to compare association of angiographic severity of vascular stenosis with CRP in patients with ST segment elevation myocardial infarction (STEMI) and non-STEMI / Unstable angina (UA). Prospective, descriptive study. Khan Research Laboratories (KRL) Hospital, from October 2014 to March 2015. CRP was measured on diagnosis of ACS in 70 patients. Cardiac enzymes were measured 6 hours after the onset of chest pain. Angiographic scoring for degree of stenosis and number of culprit vessels was done. Two groups consisting of patients with STEMI (group 1) and with NSTEMI/UA (group 2) were made. No correlation was found between CRP levels and angiographic stenosis in patients with ACS (r=0.162, p>0.05). No association was found between eosinophil count and severity of stenosis (p=0.88). Rise of cardiac enzymes and degree of coronary stenosis showed a positive correlation (p <0.001). There was significant difference in the means of coronary artery stenosis scores between the two groups (Gensini score of groups 1 and 2: 35.9 ±4 and 14 ±8, respectively) p<0.001, but there was no significant difference in CRP levels. CRP is a marker of inflammation in ACS rather than a risk factor for determining the severity of vascular stenosis. Rise in cardiac enzymes still grade high in predicting severity of vascular stenosis than eosinophil count or CRP levels.

  9. Comparison of intravascular ultrasound to contrast-enhanced 64-slice computed tomography to assess the significance of angiographically ambiguous coronary narrowings.

    PubMed

    Okabe, Teruo; Weigold, Wm Guy; Mintz, Gary S; Roswell, Robert; Joshi, Subodh; Lee, Sung Yun; Lee, Bongryeol; Steinberg, Daniel H; Roy, Probal; Slottow, Tina L Pinto; Smith, Kimberly; Torguson, Rebecca; Xue, Zhenyi; Satler, Lowell F; Kent, Kenneth M; Pichard, Augusto D; Weissman, Neil J; Lindsay, Joseph; Waksman, Ron

    2008-10-15

    The efficacy of contrast-enhanced multislice computed tomography (MSCT) for assessment of ambiguous lesions is unknown. We compared both quantitative coronary angiography (QCA) and MSCT to the gold standard for a significant stenosis-minimum luminal area (MLA) by intravascular ultrasound (IVUS)-in 51 patients (64 +/- 10 years old, 19 men) with 69 angiographically ambiguous, nonleft main lesions. The MSCT was performed 17 +/- 18 days before IVUS analysis. Overall diameter stenosis by QCAwas 51.0 +/- 9.8%; 39 of 51 patients (76%) eventually underwent revascularization (38 by percutaneous coronary intervention and 1 by coronary artery bypass graft). By univariate analysis, minimum luminal diameter, MLA, lumen visibility by MSCT, and minimum luminal diameter by QCA were significant predictors of MLA by IVUS angiographically ambiguous lesions in which QCA does not distinguish significantly from nonsignificant stenosis, MSCT-measured MLA can predict significant stenosis with MLA

  10. Comparison of computer- and human-derived coronary angiographic end-point measures for controlled therapy trials

    NASA Technical Reports Server (NTRS)

    Mack, W. J.; Selzer, R. H.; Pogoda, J. M.; Lee, P. L.; Shircore, A. M.; Azen, S. P.; Blankenhorn, D. H.

    1992-01-01

    The Cholesterol Lowering Atherosclerosis Study, a randomized angiographic clinical trial, demonstrated the beneficial effect of niacin/colestipol plus diet therapy on coronary atherosclerosis. Outcome was determined by panel-based estimates (viewed in both still and cine modes) of percent stenosis severity and change in native artery and bypass graft lesions. Computer-based quantitative coronary angiography (QCA) was also used to measure lesion and bypass graft stenosis severity and change in individual frames closely matched in orientation, opacification, and cardiac phase. Both methods jointly evaluated 350 nonoccluded lesions. The correlation between QCA and panel estimates of lesion size was 0.70 (p less than 0.0001) and for change in lesion size was 0.28 (p = 0.002). Agreement between the two methods in classifying lesion changes (i.e., regression, unchanged, or progression) occurred for 60% (210 of 350) of the lesions kappa +/- SEM = 0.20 +/- 0.05, p less than 0.001). The panel identified 442 nonoccluded lesions for which QCA stenosis measurements could not be obtained. Lesions not measurable by QCA included those with stenosis greater than 85% that could not be reliably edge tracked, segments with diffuse or ecstatic disease that had no reliable reference diameter, and segments for which matched frames could not be located. Seventy-nine lesions, the majority between 21% and 40% stenosis, were identified and measured by QCA but were not identified by the panel. This comparison study demonstrates the need to consider available angiographic measurement methods in relation to the goals of their use.

  11. Registration of angiographic image on real-time fluoroscopic image for image-guided percutaneous coronary intervention.

    PubMed

    Kim, Dongkue; Park, Sangsoo; Jeong, Myung Ho; Ryu, Jeha

    2018-02-01

    In percutaneous coronary intervention (PCI), cardiologists must study two different X-ray image sources: a fluoroscopic image and an angiogram. Manipulating a guidewire while alternately monitoring the two separate images on separate screens requires a deep understanding of the anatomy of coronary vessels and substantial training. We propose 2D/2D spatiotemporal image registration of the two images in a single image in order to provide cardiologists with enhanced visual guidance in PCI. The proposed 2D/2D spatiotemporal registration method uses a cross-correlation of two ECG series in each image to temporally synchronize two separate images and register an angiographic image onto the fluoroscopic image. A guidewire centerline is then extracted from the fluoroscopic image in real time, and the alignment of the centerline with vessel outlines of the chosen angiographic image is optimized using the iterative closest point algorithm for spatial registration. A proof-of-concept evaluation with a phantom coronary vessel model with engineering students showed an error reduction rate greater than 74% on wrong insertion to nontarget branches compared to the non-registration method and more than 47% reduction in the task completion time in performing guidewire manipulation for very difficult tasks. Evaluation with a small number of experienced doctors shows a potentially significant reduction in both task completion time and error rate for difficult tasks. The total registration time with real procedure X-ray (angiographic and fluoroscopic) images takes [Formula: see text] 60 ms, which is within the fluoroscopic image acquisition rate of 15 Hz. By providing cardiologists with better visual guidance in PCI, the proposed spatiotemporal image registration method is shown to be useful in advancing the guidewire to the coronary vessel branches, especially those difficult to insert into.

  12. Small artery elasticity predicts future cardiovascular events in chinese patients with angiographic coronary artery disease.

    PubMed

    Wan, Zhaofei; Liu, Xiaojun; Wang, Xinhong; Liu, Fuqiang; Liu, Weimin; Wu, Yue; Pei, Leilei; Yuan, Zuyi

    2014-04-01

    Arterial elasticity has been shown to predict cardiovascular disease (CVD) in apparently healthy populations. The present study aimed to explore whether arterial elasticity could predict CVD events in Chinese patients with angiographic coronary artery disease (CAD). Arterial elasticity of 365 patients with angiographic CAD was measured. During follow-up (48 months; range 6-65), 140 CVD events occurred (including 34 deaths). Univariate Cox analysis demonstrated that both large arterial elasticity and small arterial elasticity were significant predictors of CVD events. Multivariate Cox analysis indicated that small arterial elasticity remained significant. Kaplan-Meier analysis showed that the probability of having a CVD event/CVD death increased with a decrease of small arterial elasticity (P < .001, respectively). Decreased small arterial elasticity independently predicts the risk of CVD events in Chinese patients with angiographic CAD.

  13. Influence of angiographic collateral circulation on myocardial perfusion in patients with chronic total occlusion of a single coronary artery and no prior myocardial infarction.

    PubMed

    Aboul-Enein, Fatma; Kar, Saibal; Hayes, Sean W; Sciammarella, Maria; Abidov, Aiden; Makkar, Raj; Friedman, John D; Eigler, Neal; Berman, Daniel S

    2004-06-01

    The functional role of various angiographic grades for coronary collaterals remains controversial. The aim of this study was to assess the influence of the Rentrop angiographic grading of coronary collaterals on myocardial perfusion in patients with single-vessel chronic total occlusion (CTO) and no prior myocardial infarction (MI). The study included 56 patients with single-vessel CTO and no prior MI who underwent rest-stress myocardial perfusion SPECT and coronary angiography within 6 mo. All patients had angiographic evidence of coronary collaterals. Patients were divided according to the Rentrop classification: Group I had grade 1 or 2 (n = 25) and group II had grade 3 collaterals (n = 31). Group I had a higher frequency of resting regional wall motion abnormalities on left ventriculography (52.6% vs. 19.2% [P = 0.019]). The mean perfusion scores of the overall population showed severe and extensive stress perfusion defects (summed stress score of 14.1 +/- 7.1 and summed difference score of 12.9 +/- 6.9) but minimal resting perfusion defects (summed rest score of 1.0 +/- 2.7). No perfusion scores differed between the 2 groups. The perfusion findings suggested that chronic stunning rather than hibernation is the principal cause of regional wall motion abnormalities in these patients. In the setting of single-vessel CTO and no prior MI, coronary collaterals appear to protect against resting perfusion defects. Excellent angiographic collaterals may prevent resting regional wall motion abnormalities but do not appear to protect against stress-induced perfusion defects.

  14. Evaluation of Coronary Artery Stenosis by Quantitative Flow Ratio During Invasive Coronary Angiography: The WIFI II Study (Wire-Free Functional Imaging II).

    PubMed

    Westra, Jelmer; Tu, Shengxian; Winther, Simon; Nissen, Louise; Vestergaard, Mai-Britt; Andersen, Birgitte Krogsgaard; Holck, Emil Nielsen; Fox Maule, Camilla; Johansen, Jane Kirk; Andreasen, Lene Nyhus; Simonsen, Jo Krogsgaard; Zhang, Yimin; Kristensen, Steen Dalby; Maeng, Michael; Kaltoft, Anne; Terkelsen, Christian Juhl; Krusell, Lars Romer; Jakobsen, Lars; Reiber, Johan H C; Lassen, Jens Flensted; Bøttcher, Morten; Bøtker, Hans Erik; Christiansen, Evald Høj; Holm, Niels Ramsing

    2018-03-01

    Quantitative flow ratio (QFR) is a novel diagnostic modality for functional testing of coronary artery stenosis without the use of pressure wires and induction of hyperemia. QFR is based on computation of standard invasive coronary angiographic imaging. The purpose of WIFI II (Wire-Free Functional Imaging II) was to evaluate the feasibility and diagnostic performance of QFR in unselected consecutive patients. WIFI II was a predefined substudy to the Dan-NICAD study (Danish Study of Non-Invasive Diagnostic Testing in Coronary Artery Disease), referring 362 consecutive patients with suspected coronary artery disease on coronary computed tomographic angiography for diagnostic invasive coronary angiography. Fractional flow reserve (FFR) was measured in all segments with 30% to 90% diameter stenosis. Blinded observers calculated QFR (Medis Medical Imaging bv, The Netherlands) for comparison with FFR. FFR was measured in 292 lesions from 191 patients. Ten (5%) and 9 patients (5%) were excluded because of FFR and angiographic core laboratory criteria, respectively. QFR was successfully computed in 240 out of 255 lesions (94%) with a mean diameter stenosis of 50±12%. Mean difference between FFR and QFR was 0.01±0.08. QFR correctly classified 83% of the lesions using FFR with cutoff at 0.80 as reference standard. The area under the receiver operating characteristic curve was 0.86 (95% confidence interval, 0.81-0.91) with a sensitivity, specificity, negative predictive value, and positive predictive value of 77%, 86%, 75%, and 87%, respectively. A QFR-FFR hybrid approach based on the present results enables wire-free and adenosine-free procedures in 68% of cases. Functional lesion evaluation by QFR assessment showed good agreement and diagnostic accuracy compared with FFR. Studies comparing clinical outcome after QFR- and FFR-based diagnostic strategies are required. URL: https://www.clinicaltrials.gov. Unique identifier: NCT02264717. © 2018 The Authors.

  15. Visual and Quantitative Assessment of Coronary Stenoses at Angiography Versus Fractional Flow Reserve: The Impact of Risk Factors.

    PubMed

    Adjedj, Julien; Xaplanteris, Panagiotis; Toth, Gabor; Ferrara, Angela; Pellicano, Mariano; Ciccarelli, Giovanni; Floré, Vincent; Barbato, Emanuele; De Bruyne, Bernard

    2017-07-01

    The correlation between angiographic assessment of coronary stenoses and fractional flow reserve (FFR) is weak. Whether and how risk factors impact the diagnostic accuracy of angiography is unknown. We sought to evaluate the diagnostic accuracy of angiography by visual estimate and by quantitative coronary angiography when compared with FFR and evaluate the influence of risk factors (RF) on this accuracy. In 1382 coronary stenoses (1104 patients), percent diameter stenosis by visual estimation (DS VE ) and by quantitative coronary angiography (DS QCA ) was compared with FFR. Patients were divided into 4 subgroups, according to the presence of RFs, and the relationship between DS VE , DS QCA , and FFR was analyzed. Overall, DS VE was significantly higher than DS QCA ( P <0.0001); nonetheless, when examined by strata of DS, DS VE was significantly smaller than DS QCA in mild stenoses, although the reverse held true for severe stenoses. Compared with FFR, a large scatter was observed for both DS VE and DS QCA . When using a dichotomous FFR value of 0.80, C statistic was significantly higher for DS VE than for DS QCA (0.712 versus 0.640, respectively; P <0.001). C statistics for DS VE decreased progressively as RFs accumulated (0.776 for ≤1 RF, 0.750 for 2 RFs, 0.713 for 3 RFs and 0.627 for ≥4 RFs; P =0.0053). In addition, in diabetics, the relationship between FFR and angiographic indices was particularly weak (C statistics: 0.524 for DS VE and 0.511 for DS QCA ). Overall, DS VE has a better diagnostic accuracy than DS QCA to predict the functional significance of coronary stenosis. The predictive accuracy of angiography is moderate in patients with ≤1 RFs, but weakens as RFs accumulate, especially in diabetics. © 2017 American Heart Association, Inc.

  16. Impact of lesion morphology and associated procedures for left main coronary stenting on angiographic outcome after intervention: sub-analysis of Heart Research Group of Kanazawa, HERZ, Study.

    PubMed

    Kawashiri, Masa-aki; Sakata, Kenji; Uchiyama, Katsuharru; Konno, Tetsuo; Namura, Masanobu; Mizuno, Sumio; Tatami, Ryozo; Kanaya, Honin; Nitta, Yutaka; Michishita, Ichiro; Hirase, Hiroaki; Ueda, Kosei; Aoyama, Takashi; Okeie, Kazuyasu; Haraki, Tatsuo; Mori, Kiyoo; Araki, Tsutomu; Minamoto, Masaharu; Oiwake, Hisanori; Ino, Hidekazu; Hayashi, Kenshi; Yamagishi, Masakazu

    2014-04-01

    Whether the lesion morphology and associated interventional procedures for the left main coronary artery disease (LMCA) could affect clinical outcome is still controversial. Therefore, we examined the impact of lesion morphology and associated procedures on clinical and angiographic outcomes of stenting for the LMCA. Among 7,660 patients with coronary intervention registered, we analyzed early angiographic results of 228 patients (179 men, mean age 69.4 years) concerned with LMCA lesions. In 121 out of 228 patients having long-term angiographic results, we examined the occurrence of major adverse coronary events (MACE) particularly in terms of the presence of acute coronary syndrome (ACS), the kind of stents, bear metal or drug eluting, the lesion morphology and associated procedures. Early angiographic success rate of LMCA stenting was 100 %, and clinical success rate was 94.3 %. During follow-up period for 3 years, MACE was observed in 17 patients. Under these conditions, multiple stenting (p < 0.01) and complicated procedures such as such as Y-stent, T-stent and crush stent (p < 0.01) were listed as risks for MACE, although there was no statistical difference in kinds of stent. Multivariate analysis demonstrated the significant disadvantage of complicated procedures using the bear metal stent on the occurrence of MACE (p < 0.01). These results demonstrate that the complicated procedures have great impact on clinical and angiographic outcomes after stenting for LMCA lesions, and suggest the simple procedure with a single stent for LMCA lesions in the present cohort. Whether the presence of ACS can affect the prognosis should further be sought.

  17. Chest pain in patients with arterial hypertension, angiographically normal coronary arteries and stiff aorta: the aortic pain syndrome.

    PubMed

    Stakos, Dimitrios A; Tziakas, Dimitrios N; Chalikias, George; Mitrousi, Konstantina; Tsigalou, Christina; Boudoulas, Harisios

    2013-01-01

    Arterial hypertension is often associated with a stiff aorta as a result of collagen accumulation in the aortic wall and may produce chest pain. In the present study, possible interrelationships between aortic function, collagen turnover and exercise-induced chest pain in patients with arterial hypertension and angiographically normal coronary arteries were investigated. Ninety-seven patients with arterial hypertension, angiographically normal coronary arteries and no evidence of myocardial ischemia on nuclear cardiac imaging during exercise test were studied. Of these, 43 developed chest pain during exercise (chest pain group) while 54 did not (no chest pain group). Carotid femoral pulse-wave velocity (PWVc-f) was used to assess the elastic properties of the aorta. Amino-terminal pro-peptides of pro-collagen type I, (PINP, reflecting collagen synthesis), serum telopeptides of collagen type I (CITP, reflecting collagen degradation), pro-metalloproteinase 1 (ProMMP-1), and tissue inhibitor of metalloproteinase 1 (TIMP-1, related to collagen turnover) were measured in plasma by immunoassay. The chest pain group had higher PWVc-f, higher and /CITP ratio, and lower proMMP-1/ TIMP-1 ratio compared to the no chest pain group. PWVc-f (t=2.53, p=0.02) and PINP (t=2.42, p=0.02) were independently associated with the presence of chest pain in multiple regression analysis. Patients with arterial hypertension, exercise-induced chest pain and angiographically normal coronary arteries, without evidence of exercise-induced myocardial ischemia, had a stiffer aorta compared to those without chest pain. Alterations in collagen type I turnover that favor collagen accumulation in the aortic wall may contribute to aortic stiffening and chest pain in these patients.

  18. ANGIOCARE: an automated system for fast three-dimensional coronary reconstruction by integrating angiographic and intracoronary ultrasound data.

    PubMed

    Bourantas, Christos V; Kalatzis, Fanis G; Papafaklis, Michail I; Fotiadis, Dimitrios I; Tweddel, Ann C; Kourtis, Iraklis C; Katsouras, Christos S; Michalis, Lampros K

    2008-08-01

    The development of an automated, user-friendly system (ANGIOCARE), for rapid three-dimensional (3D) coronary reconstruction, integrating angiographic and, intracoronary ultrasound (ICUS) data. Biplane angiographic and ICUS sequence images are imported into the system where a prevalidated method is used for coronary reconstruction. This incorporates extraction of the catheter path from two end-diastolic X-ray images and detection of regions of interest (lumen, outer vessel wall) in the ICUS sequence by an automated border detection algorithm. The detected borders are placed perpendicular to the catheter path and established algorithms used to estimate their absolute orientation. The resulting 3D object is imported into an advanced visualization module with which the operator can interact, examine plaque distribution (depicted as a color coded map) and assess plaque burden by virtual endoscopy. Data from 19 patients (27 vessels) undergoing biplane angiography and ICUS were examined. The reconstructed vessels were 21.3-80.2 mm long. The mean difference was 0.9 +/- 2.9% between the plaque volumes measured using linear 3D ICUS analysis and the volumes, estimated by taking into account the curvature of the vessel. The time required to reconstruct a luminal narrowing of 25 mm was approximately 10 min. The ANGIOCARE system provides rapid coronary reconstruction allowing the operator accurately to estimate the length of the lesion and determine plaque distribution and volume. (c) 2008 Wiley-Liss, Inc.

  19. Quantification of coronary microvascular resistance using angiographic images for volumetric blood flow measurement: in vivo validation

    PubMed Central

    Zhang, Zhang; Takarada, Shigeho

    2011-01-01

    Structural coronary microcirculation abnormalities are important prognostic determinants in clinical settings. However, an assessment of microvascular resistance (MR) requires a velocity wire. A first-pass distribution analysis technique to measure volumetric blood flow has been previously validated. The aim of this study was the in vivo validation of the MR measurement technique using first-pass distribution analysis. Twelve anesthetized swine were instrumented with a transit-time ultrasound flow probe on the proximal segment of the left anterior descending coronary artery (LAD). Microspheres were injected into the LAD to create a model of microvascular dysfunction. Adenosine (400 μg·kg−1·min−1) was used to produce maximum hyperemia. A region of interest in the LAD arterial bed was drawn to generate time-density curves using angiographic images. Volumetric blood flow measurements (Qa) were made using a time-density curve and the assumption that blood was momentarily replaced with contrast agent during the injection. Blood flow from the flow probe (Qp), coronary pressure (Pa), and right atrium pressure (Pv) were continuously recorded. Flow probe-based normalized MR (NMRp) and angiography-based normalized MR (NMRa) were calculated using Qp and Qa, respectively. In 258 measurements, Qa showed a strong correlation with the gold standard Qp (Qa = 0.90 Qp + 6.6 ml/min, r2 = 0.91, P < 0.0001). NMRa correlated linearly with NMRp (NMRa = 0.90 NMRp + 0.02 mmHg·ml−1·min−1, r2 = 0.91, P < 0.0001). Additionally, the Bland-Altman analysis showed a close agreement between NMRa and NMRp. In conclusion, a technique based on angiographic image data for quantifying NMR was validated using a swine model. This study provides a method to measure NMR without using a velocity wire, which can potentially be used to evaluate microvascular conditions during coronary arteriography. PMID:21398596

  20. AGE-Related Differences of Novel Atherosclerotic Risk Factors and Angiographic Profile Among Gujarati Acute Coronary Syndrome Patients

    PubMed Central

    Joshi, Hasit; Sahoo, Sibasis; Virpariya, Kapil; Parmar, Meena; Shah, Komal

    2015-01-01

    Context Although numerous risk factors have been established to predict the development of acute coronary syndrome (ACS), the risk factor profile may be different between the younger and older individuals. Aim To analyse the frequency and pattern of atherogenic risk factors and angiographic profiles in age-stratified Gujarati patients with ACS. Materials and Methods ACS patients undergoing coronary angiography at U.N. Mehta Institute of Cardiology and Research, Gujarat, India between January 2008 and December 2012 were classified in to two age groups with 40y as cut-off. Patients were assessed for conventional risk factors (diabetes mellitus, dyslipidaemia, hypertension, smoking, obesity), novel risk factors (high sensitivity C-reactive protein, lipoprotein (a), homocysteine), and angiographic profiles.The statistical difference between two age groups was determined by Student’s t-test for continuous variables and Chi-square or Fisher’s exact test for categorical variables. Results A total of 200 patients, 100 patients ≤40 y of age and 100 patients >40 y of age, were evaluated. Older patients had higher frequency of hypertension (32 vs. 16%, p=0.008), while family history of coronary artery disease was more common among younger patients (19 vs. 9%, p=0.041). The incidence of diabetes, dyslipidaemia, smoking and tobacco chewing did not vary significantly between the two groups. Total cholesterol and low-density lipoprotein cholesterol levels were significantly higher in the younger group (p<0.05). Lipoprotein (a), homocysteine and high-sensitivity C reactive protein levels were comparable between two age groups. Multi-vessel coronary artery disease was more common among older group. The most commonly affected coronary artery was the left anterior descending artery among younger patients (44%) and the left circumflex artery among older patients (38.1%). Conclusion Young patients with ACS had different atherosclerotic risk profile and less extensive coronary

  1. Relationship of myocardial hibernation, scar, and angiographic collateral flow in ischemic cardiomyopathy with coronary chronic total occlusion.

    PubMed

    Wang, Li; Lu, Min-Jie; Feng, Lei; Wang, Juan; Fang, Wei; He, Zuo-Xiang; Dou, Ke-Fei; Zhao, Shi-Hua; Yang, Min-Fu

    2018-03-07

    The relationship between myocardial viability and angiographic collateral flow is not fully elucidated in ischemic cardiomyopathy (ICM) with coronary artery chronic total occlusion (CTO). We aimed to clarify the relationship between myocardial hibernation, myocardial scar, and angiographic collateral flow in these patients. Seventy-one consecutive ICM patients with 122 CTOs and 652 dysfunctional segments within CTO territories were retrospectively analyzed. Myocardial hibernation (perfusion-metabolism mismatch) and the extent of 18 F-fluorodeoxyglucose (FDG) abnormalities were assessed using 99m Tc-sestamibi and 18 F-FDG imaging. Myocardial scar was evaluated by late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) imaging. Collateral flow observed on coronary angiography was assessed using Rentrop classification. In these patients, neither the extent nor frequency of myocardial hibernation or scar was related to the status of collateral flow. Moreover, the matching rate in determining myocardial viability was poor between any 2 imaging indices. The extent of 18 F-FDG abnormalities was linearly related to the extent of LGE rather than myocardial hibernation. Of note, nearly one-third (30.4%) of segments with transmural scar still had hibernating tissue. Hibernation and non-transmural scar had higher sensitivity (63.0% and 66.7%) than collateral flow (37.0%) in predicting global functional improvement. Angiographic collateral cannot accurately predict myocardial viability, and has lower sensitivity in prediction of functional improvement in CTO territories in ICM patients. Hence, assessment of myocardial viability with non-invasive imaging modalities is of importance. Moreover, due to the lack of correlation between myocardial hibernation and scar, these two indices are complementary but not interchangeable.

  2. The Five-Year Clinical and Angiographic Follow-Up Outcomes of Intracoronary Transfusion of Circulation-Derived CD34+ Cells for Patients With End-Stage Diffuse Coronary Artery Disease Unsuitable for Coronary Intervention-Phase I Clinical Trial.

    PubMed

    Sung, Pei-Hsun; Lee, Fan-Yen; Tong, Meng-Shen; Chiang, John Y; Pei, Sung-Nan; Ma, Ming-Chun; Li, Yi-Chen; Chen, Yung-Lung; Wu, Chiung-Jen; Sheu, Jiunn-Jye; Lee, Mel S; Yip, Hon-Kan

    2018-05-01

    This study investigated the clinical and angiographic long-term outcomes of intracoronary transfusion of circulation-derived CD34+ cells for patients with end-stage diffuse coronary artery disease unsuitable for coronary intervention. A single-center prospective randomized double-blinded phase I clinical trial. Thirty-eight patients undergoing CD34+ cell therapy were allocated into groups 1 (1.0 × 10 cells/each vessel; n = 18) and 2 (3.0 × 10 cells/each vessel; n = 20). Those with end-stage diffuse coronary artery disease were unsuitable for percutaneous and surgical coronary revascularization. Intracoronary delivery of circulation-derived CD34+ cells. We prospectively evaluated long-term clinical and echocardiographic/angiographic outcomes between survivors and nonsurvivors. By the end of 5-year follow-up, the survival rate and major adverse cardio/cerebrovascular event were 78.9% (30/38) and 36.8% (14/38), respectively. During follow-up period, 31.6% patients (12/38) received coronary stenting for reason of sufficient target vessel size grown-up after the treatment. Endothelial function was significantly reduced in the nonsurvivors than the survivors (p = 0.039). Wimasis image analysis of angiographic findings showed that the angiogenesis was significantly and progressively increased from baseline to 1 and 5 years (all p < 0.001). The 3D echocardiography showed left ventricular ejection fraction increased from baseline to 1 year and then remained stable up to 5 years, whereas left ventricular chamber diameter exhibited an opposite pattern to left ventricular ejection fraction among the survivors. The clinical scores for angina and heart failure were significantly progressively reduced from baseline to 1 and 5 years (all p < 0.001). CD34+ cell therapy for end-stage diffuse coronary artery disease patients might contribute to persistently long-term effects on improvement of left ventricular function, angina/heart failure, and amelioration of left

  3. A quantitative evaluation of the three dimensional reconstruction of patients' coronary arteries.

    PubMed

    Klein, J L; Hoff, J G; Peifer, J W; Folks, R; Cooke, C D; King, S B; Garcia, E V

    1998-04-01

    Through extensive training and experience angiographers learn to mentally reconstruct the three dimensional (3D) relationships of the coronary arterial branches. Graphic computer technology can assist angiographers to more quickly visualize the coronary 3D structure from limited initial views and then help to determine additional helpful views by predicting subsequent angiograms before they are obtained. A new computer method for facilitating 3D reconstruction and visualization of human coronary arteries was evaluated by reconstructing biplane left coronary angiograms from 30 patients. The accuracy of the reconstruction was assessed in two ways: 1) by comparing the vessel's centerlines of the actual angiograms with the centerlines of a 2D projection of the 3D model projected into the exact angle of the actual angiogram; and 2) by comparing two 3D models generated by different simultaneous pairs on angiograms. The inter- and intraobserver variability of reconstruction were evaluated by mathematically comparing the 3D model centerlines of repeated reconstructions. The average absolute corrected displacement of 14,662 vessel centerline points in 2D from 30 patients was 1.64 +/- 2.26 mm. The average corrected absolute displacement of 3D models generated from different biplane pairs was 7.08 +/- 3.21 mm. The intraobserver variability of absolute 3D corrected displacement was 5.22 +/- 3.39 mm. The interobserver variability was 6.6 +/- 3.1 mm. The centerline analyses show that the reconstruction algorithm is mathematically accurate and reproducible. The figures presented in this report put these measurement errors into clinical perspective showing that they yield an accurate representation of the clinically relevant information seen on the actual angiograms. These data show that this technique can be clinically useful by accurately displaying in three dimensions the complex relationships of the branches of the coronary arterial tree.

  4. Immediate and late clinical and angiographic outcomes after GFX coronary stenting: is high-pressure balloon dilatation necessary?

    PubMed

    Park, S W; Hong, M K; Lee, C W; Kim, J J; Park, H K; Cho, G Y; Kang, D H; Song, J K; Park, S J

    2000-08-01

    The GFX stent is a balloon-expandable stent made of sinusoidal element of stainless steel. The adjunct high-pressure balloon dilatations were usually recommended in routine stenting procedure. The aim of this study was to evaluate the immediate and long-term clinical and angiographic outcomes and to investigate the necessity of high-pressure balloon dilatation during GFX stenting. In all, 172 consecutive patients underwent single 12 or 18 mm GFX stent implantation in 188 native coronary lesions. Two types of stenting technique were used: (1) stent size of a final stent-to-artery ratio of 1:1 (inflation pressure > 10 atm, high-pressure group), and (2) stent size of 0.5 mm bigger than reference vessel (inflation pressure < or = 10 atm, low-pressure group). The adjunct high-pressure balloon dilatations were performed only in cases of suboptimal results. The adjunct high-pressure balloon dilatation was required in 11 of 83 lesions (13%) in the high-pressure group and in 7 of 105 lesions (7%) in the low-pressure group (p = 0.203). Procedural success rate was 100%. There were no significant differences of in-hospital and long-term clinical events between the two groups. The overall angiographic restenosis rate was 17.7%; 18.4% in the high-pressure group and 17.1% in the low-pressure group (p = 0.991). The GFX stent is a safe and effective device with a high procedural success rate and favorable late clinical outcome for treatment of native coronary artery disease. Further randomized trials may be needed to compare stenting techniques in GFX stent implantation.

  5. Experimental Evaluation of a New Single Wire Stainless Steel Fishscale Coronary Stent (Freedomª).

    PubMed

    Wang; Verbeken; Mukherjee; Zhou; De Scheerder IK

    1996-10-01

    Recent randomized clinical trials revealed a significant reduction in angiographic restenosis rates when adjunctive stenting was performed after conventional coronary balloon angioplasty. Current approved coronary stents are however hampered by their rigidity, limiting their trackability in tortuous vessels and furthermore, needing high pressure deployment for optimal vessel apposition. New coronary stents are currently under development, using more biocompatible metal alloys and/or designs which better align to the vessel wall at moderate deployment pressures. We evaluated the safety, efficacy, angiographic and histological effect of a new stainless steel fishscale designed stent (Freedomª, Global Therapeutics, Co., USA) in a porcine coronary and peripheral artery model. Implantation in the right coronary artery was successful in all 20 pigs. Control angiograms at 6 weeks follow-up demonstrated patent vessels and morphologic evaluation showed only a mild fibromuscular neointimal response resulting in an area stenosis of 28.7 +/- 0.18% and a mean neointimal hyperplasia of 0.18 +/- 0.25 mm. Comparison with the Palmaz-Schatzª coronary stent in a porcine peripheral artery model demonstrated similar quantitative angiographic and morphologic vessel analysis results. Also the morphometric data were comparable. Area stenosis: Palmaz-Schatz: 37 +/- 0.24%, Freedom: 21 +/- 0.14%, p = 0.07. Mean neointimal hyperplasia: Palmaz-Schatz: 0.33 +/- 0.24 mm, Freedom: 0.18 +/- 0.08 mm, p = 0.08. CONCLUSION: Freedom coronary stent implantation in a porcine model resulted in a high procedural success without subacute thrombotic occlusions, despite no further anticoagulation nor antiplatelet therapy. Six weeks histopathological and morphometric evaluation demonstrated only a mild fibromuscular neointimal hyperplasia.

  6. Automated myocardial perfusion from coronary x-ray angiography

    NASA Astrophysics Data System (ADS)

    Storm, Corstiaan J.; Slump, Cornelis H.

    2010-03-01

    The purpose of our study is the evaluation of an algorithm to determine the physiological relevance of a coronary lesion as seen in a coronary angiogram. The aim is to extract as much as possible information from a standard coronary angiogram to decide if an abnormality, percentage of stenosis, as seen in the angiogram, results in physiological impairment of the blood supply of the region nourished by the coronary artery. Coronary angiography, still the golden standard, is used to determine the cause of angina pectoris based on the demonstration of an important stenose in a coronary artery. Dimensions of a lesion such as length and percentage of narrowing can at present easily be calculated by using an automatic computer algorithm such as Quantitative Coronary Angiography (QCA) techniques resulting in just anatomical information ignoring the physiological relevance of the lesion. In our study we analyze myocardial perfusion images in standard coronary angiograms in rest and in artificial hyperemic phases, using a drug e.g. papaverine intracoronary. Setting a Region of Interest (ROI) in the angiogram without overlying major vessels makes it possible to calculate contrast differences as a function of time, so called time-density curves, in the basal and hyperemic phases. In minimizing motion artifacts, end diastolic images are selected ECG based in basal and hyperemic phase in an identical ROI in the same angiographic projection. The development of new algorithms for calculating differences in blood supply in the region as set are presented together with the results of a small clinical case study using the standard angiographic procedure.

  7. Quantitative 4D Transcatheter Intraarterial Perfusion MR Imaging as a Method to Standardize Angiographic Chemoembolization Endpoints

    PubMed Central

    Jin, Brian; Wang, Dingxin; Lewandowski, Robert J.; Ryu, Robert K.; Sato, Kent T.; Larson, Andrew C.; Salem, Riad; Omary, Reed A.

    2011-01-01

    PURPOSE We aimed to test the hypothesis that subjective angiographic endpoints during transarterial chemoembolization (TACE) of hepatocellular carcinoma (HCC) exhibit consistency and correlate with objective intraprocedural reductions in tumor perfusion as determined by quantitative four dimensional (4D) transcatheter intraarterial perfusion (TRIP) magnetic resonance (MR) imaging. MATERIALS AND METHODS This prospective study was approved by the institutional review board. Eighteen consecutive patients underwent TACE in a combined MR/interventional radiology (MR-IR) suite. Three board-certified interventional radiologists independently graded the angiographic endpoint of each procedure based on a previously described subjective angiographic chemoembolization endpoint (SACE) scale. A consensus SACE rating was established for each patient. Patients underwent quantitative 4D TRIP-MR imaging immediately before and after TACE, from which mean whole tumor perfusion (Fρ) was calculated. Consistency of SACE ratings between observers was evaluated using the intraclass correlation coefficient (ICC). The relationship between SACE ratings and intraprocedural TRIP-MR imaging perfusion changes was evaluated using Spearman’s rank correlation coefficient. RESULTS The SACE rating scale demonstrated very good consistency among all observers (ICC = 0.80). The consensus SACE rating was significantly correlated with both absolute (r = 0.54, P = 0.022) and percent (r = 0.85, P < 0.001) intraprocedural perfusion reduction. CONCLUSION The SACE rating scale demonstrates very good consistency between raters, and significantly correlates with objectively measured intraprocedural perfusion reductions during TACE. These results support the use of the SACE scale as a standardized alternative method to quantitative 4D TRIP-MR imaging to classify patients based on embolic endpoints of TACE. PMID:22021520

  8. Vitamin D deficiency, coronary artery disease, and endothelial dysfunction: observations from a coronary angiographic study in Indian patients.

    PubMed

    Syal, Sanjeev Kumar; Kapoor, Aditya; Bhatia, Eesh; Sinha, Archana; Kumar, Sudeep; Tewari, Satyendra; Garg, Naveen; Goel, Pravin K

    2012-08-01

    Vitamin D deficiency has been linked to an increased risk of coronary artery disease (CAD) and cardiovascular (CV) death. Endothelial dysfunction plays an important role in pathogenesis of CAD and vitamin D deficiency is postulated to promote endothelial dysfunction. Despite rising trends of CAD in Asians, only limited data are available on the relationship between vitamin D, CAD, and endothelial dysfunction. In a study of 100 patients undergoing coronary angiography, mean 25(OH)D level was 14.8 ± 9.1 ng/mL; vitamin D deficiency was present in 80% and only 7% had optimal 25(OH)D levels. Nearly one-third (36%) were severely deficient, with 25(OH)D levels <10 ng/mL. Those with vitamin D deficiency had significantly higher prevalence of double- or triple-vessel CAD (53% vs 38%), diffuse CAD (56% vs 34%), and higher number of coronary vessels involved as compared to those with higher 25(OH)D levels. Those with lower 25(OH)D levels had significantly lower brachial artery flow-mediated dilation (FMD; 4.57% vs 10.68%: P<.001) and significantly higher prevalence of impaired FMD (values <4.5%; 50.6% vs 7%; P<.002). A graded relationship between 25(OH)D levels and FMD was observed; impaired FMD was noted in 62.2%, 38.6%, and 13.3% in those with 25(OH)D levels <10 ng/mL, 10-20 ng/mL, and >20 ng/mL, respectively. Indian patients with angiographically documented CAD frequently have vitamin D deficiency. Patients with lower 25(OH)D levels had higher prevalence of double- or triple-vessel CAD and diffuse CAD. Endothelial dysfunction as assessed by brachial artery FMD was also more frequently observed in those with low 25(OH)D levels.

  9. The impact of acquisition angle differences on three-dimensional quantitative coronary angiography.

    PubMed

    Tu, Shengxian; Holm, Niels R; Koning, Gerhard; Maeng, Michael; Reiber, Johan H C

    2011-08-01

    Three-dimensional (3D) quantitative coronary angiography (QCA) requires two angiographic views to restore vessel dimensions. This study investigated the impact of acquisition angle differences (AADs) of the two angiographic views on the assessed dimensions by 3D QCA. X-ray angiograms of an assembled brass phantom with different types of straight lesions were recorded at multiple angiographic projections. The projections were randomly matched as pairs and 3D QCA was performed in those pairs with AAD larger than 25°. The lesion length and diameter stenosis in three different lesions, a circular concentric severe lesion (A), a circular concentric moderate lesion (B), and a circular eccentric moderate lesion (C), were measured by 3D QCA. The acquisition protocol was repeated for a silicone bifurcation phantom, and the bifurcation angles and bifurcation core volume were measured by 3D QCA. The measurements were compared with the true dimensions if applicable and their correlation with AAD was studied. 50 matched pairs of angiographic views were analyzed for the brass phantom. The average value of AAD was 48.0 ± 14.1°. The percent diameter stenosis was slightly overestimated by 3D QCA for all lesions: A (error 1.2 ± 0.9%, P < 0.001); B (error 0.6 ± 0.5%, P < 0.001); C (error 1.1 ± 0.6%, P < 0.001). The correlation of the measurements with AAD was only significant for lesion A (R(2) = 0.151, P = 0.005). The lesion length was slightly overestimated by 3D QCA for lesion A (error 0.06 ± 0.18 mm, P = 0.026), but well assessed for lesion B (error -0.00 ± 0.16 mm, P = 0.950) and lesion C (error -0.01 ± 0.18 mm, P = 0.585). The correlation of the measurements with AAD was not significant for any lesion. Forty matched pairs of angiographic views were analyzed for the bifurcation phantom. The average value of AAD was 49.1 ± 15.4°. 3D QCA slightly overestimated the proximal angle (error 0.4 ± 1.1°, P = 0.046) and the distal angle (error 1.5 ± 1.3°, P < 0.001). The

  10. Coronary Angiography Findings and Its Determinants in Patients Presenting With Acute Coronary Syndrome: A Descriptive Analysis from Asian Population.

    PubMed

    Chourasiya, M; Satheesh, S; Selvaraj, R; Jayaraman, B; Pillai, A A

    2017-10-01

    The aim was to study the angiographic profile in patients presented as acute coronary syndrome and its relation with risk factors and comparison between genders. This prospective observational study was performed on total 352 patients of acute coronary syndrome were analyzed for various risk factors, angiographic pattern in Jawaharlal Institute of Postgraduate Medical Education and Research (JIPMER), Puducherry, South India from January 2015 to July 2016. Mean age of presentation was 52.62±11.63 years. Male were 271(77.0%) and female were 81(23.0%). Majority of patients were STEMI (67.6%) followed by UA (24.4%) and NSTEMI (8%). Smoker was 117(33.3%) patients. Hypertensive were 124(35.2%) of patients and 149(42.3%) were diabetics. Family history of CAD was positive in 45(12.8%). On angiographic evaluation left main reference diameter was lower in females (4.02±0.72) than males (4.07±0.82). LAD was most commonly involved followed by RCA and LCX among all three group of acute coronary syndrome. Left main was least involved (8.3%). In STEMI SVD (40.3%) was most common presentation, after that DVD was seen in 22.3%, TVD in 10.5%, non-obstructive coronary was seen in 16% of patients and normal coronary was seen in 11% of patients. In UA 28%, 22.8%, 13.2%, 15.8%, 20.2% was seen in SVD, DVD, TVD, non-obstructive and normal coronary respectively. Long length coronary lesions (>20mm) were seen in majority in all type of acute coronary syndrome. Coronary lesion length was not associated with presentation acute coronary syndrome and genders. Male were most commonly presented as acute coronary syndrome. STEMI was most common presentation. Diabetic was most prevalent risk factor. SVD was most common angiographic pattern and LAD was most common involved arteries.

  11. Early and late effects of coumarin therapy started before percutaneous coronary intervention: Clinical, angiographic and cost-effective outcome of the Balloon Angioplasty and Anticoagulation Study (BAAS).

    PubMed

    Ten Berg, J M; Kelder, J C; Suttorp, M J; Mast, E G; Bal, E T; Ernst, J M P G; Plokker, H W M

    2002-05-01

    Coronary angioplasty frequently creates a thrombogenic surface with subsequent mural thrombosis that may lead to acute complications and possibly stimulates the development of restenosis. Whether coumarins can prevent these complications is unclear. In the Balloon Angioplasty and Anticoagulation Study (BAAS), the effect of coumarins started before the procedure on early and late outcome was studied. Patients were randomised to aspirin only or to aspirin plus coumarins. Half of the patients were randomised to undergo six-month angiographic follow-up. Study medication was started one week before coronary angioplasty and the target international normalised ratio (INR) was 2.1-4.8 during angioplasty and six-month follow-up. 'Optimal' anticoagulation was defined as an INR in the target range for at least 70% of the follow-up time. In addition, cost-effectiveness of coumarin treatment was measured. At one year death, myocardial infarction, target-lesion revascularisation and stroke were observed in 14.3% of the 530 patients randomised to aspirin plus coumarin versus in 20.3% of the 528 patients randomised to aspirin alone (relative risk 0.71; 95% CI 0.54-0.93). The incidence of major bleedings and false aneurysms during hospitalisation was 3.2% and 1.0%, respectively, (relative risk 3.39; 95% CI 1.26-9.11). Optimal anticoagulation was an independent predictor of late thrombotic events (relative risk, 0.33; 95% CI, 0.19-0.57). Quantitative coronary analysis was performed of 301 lesions in the ASA group and of 297 lesions in the coumarin group. At six months, the minimal luminal diameter was similar in the ASA and coumarin group. However, optimal anticoagulation was an independent predictor of angiographic outcome at six months. Optimal anticoagulation led to a 0.21 mm (95% CI: 0.05-0.37) larger MLD as compared with suboptimal anticoagulation whereas aspirin use led to a 0.12 mm (95% CI -0.28-0.04) smaller MLD. When including all costs, the savings associated with coumarin

  12. Serum creatinine is independently associated with angiographic extent of coronary artery disease in patients with stable angina pectoris.

    PubMed

    Korkmaz, Şule; Demirkan, Burcu; Altay, Hakan; Refiker Ege, Meltem; Çaldır, Vedat; Yılmaz, Mehmet Birhan; Güray, Yeşim; Güray, Ümit; Şaşmaz, Hatice

    2011-08-01

    Renal dysfunction has been shown to be linked to high risk for cardiovascular events. Even milder forms of creatinine elevation are associated with poor cardiovascular outcomes. We designed a retrospective study and searched the association of angiographic extent of coronary artery disease and creatinine levels in patients without overt renal dysfunction. We retrospectively reviewed 892 consecutive patients with typical stable angina pectoris (311 female with mean age of 62 ± 10 years, 581 male with mean age of 56 ± 11 years) at Türkiye Yüksek İhtisas Hospital and creatinine level ≤ 3 mg/dl without history of hemodialysis. Patients without overt renal disease were divided into 3 groups according to level of creatinine (Group A: Cr level <1.2 mg/dl, Group B: Cr level ≥ 1.2 and <1.5 mg/dl and Group C: Cr level ≥ 1.5 -≤ 3 mg/dl). Additionally after evaluation of coronary angiograms, patients were also classified according to those with high stenosis (stenosis score ≥ 16) and high extension scores (extension score >50%) versus low stenosis and low extension scores. Logistic regression analysis was performed to establish the clinical predictors of high total stenosis and high extension scores. Each group of patients according to level of creatinine showed marked difference in terms of angiographic extent of coronary artery disease (p<0.001). Those in the highest creatinine group (≥ 1.5 mg/dl, but not above 3 mg/dl) had the highest total stenosis (17 ± 6, p<0.001) and extension (78 ± 25, p<0.001) scores irrespective of age and gender. Creatinine was shown to be significantly correlated with both stenosis and extension scores. Age (OR:1.035, 95% CI:1.016-1.054, p<0.0001), being male (OR:1.746, 95% CI: 1.135-2.685, p=0.011), presence of hypertension (OR:1.507, 95%CI: 1.005-2.25 p=0.047), presence of diabetes mellitus (OR: 1.865, 95%: 1.250-2.783, p=0.002), previous history of myocardial infarction (OR: 1.624, 95%CI: 1.094-2.413, p=0.016), wall motion

  13. Magnetic navigation system assisted stenting of coronary bifurcation lesions.

    PubMed

    Simsek, Cihan; Magro, Michael; Patterson, Mark S; Onuma, Yoshinobu; Ciampichetti, Isabella; van Weenen, Sander; van Domburg, Ron T; Serruys, Patrick W; Boersma, Eric; van Geuns, Robert-Jan

    2011-03-01

    Magnetic guidewire assisted percutaneous coronary interventions (MPCI) could have certain advantages in coronary bifurcation lesions. We aimed to report the angiographic characteristics of the bifurcation lesions, as well as the procedural and clinical outcomes of the MPCI patients. The lesion characteristics and the treatment effect were assessed by performing diagnostic and quantitative coronary angiography with dedicated bifurcation software. A total of 76 patients (age 65 years, 78% male) were assigned to undergo MPCI, in which two-thirds of the lesions were located in LAD/D1. Fifty-seven out of 78 lesions (73%) had a diseased side branch and complex stenting techniques were used in the majority of the lesions (64%). All 59/78 (76%) fenestration attempts were successfully performed and only 13 dedicated bifurcation stents were implanted. The average acute gain in minimal luminal diameter was 1.08±0.81 mm, 0.80±0.70 mm and 0.59±0.56 mm for the proximal, distal and side branch, respectively. The procedural success was 69% with a procedure time of 107±43 minutes, fluoroscopy time of 34±24 minutes and contrast use of 338±136 ml. At a mean of 1.8-years follow-up, 15 patients (20%) had a cardiac event. MPCI is associated with good angiographic, fenestration and procedural success rates in the treatment of coronary bifurcation lesions.

  14. Identification of ADAMTS7 as a novel locus for coronary atherosclerosis and association of ABO with myocardial infarction in the presence of coronary atherosclerosis: two genome-wide association studies.

    PubMed

    Reilly, Muredach P; Li, Mingyao; He, Jing; Ferguson, Jane F; Stylianou, Ioannis M; Mehta, Nehal N; Burnett, Mary Susan; Devaney, Joseph M; Knouff, Christopher W; Thompson, John R; Horne, Benjamin D; Stewart, Alexandre F R; Assimes, Themistocles L; Wild, Philipp S; Allayee, Hooman; Nitschke, Patrick Linsel; Patel, Riyaz S; Martinelli, Nicola; Girelli, Domenico; Quyyumi, Arshed A; Anderson, Jeffrey L; Erdmann, Jeanette; Hall, Alistair S; Schunkert, Heribert; Quertermous, Thomas; Blankenberg, Stefan; Hazen, Stanley L; Roberts, Robert; Kathiresan, Sekar; Samani, Nilesh J; Epstein, Stephen E; Rader, Daniel J

    2011-01-29

    We tested whether genetic factors distinctly contribute to either development of coronary atherosclerosis or, specifically, to myocardial infarction in existing coronary atherosclerosis. We did two genome-wide association studies (GWAS) with coronary angiographic phenotyping in participants of European ancestry. To identify loci that predispose to angiographic coronary artery disease (CAD), we compared individuals who had this disorder (n=12,393) with those who did not (controls, n=7383). To identify loci that predispose to myocardial infarction, we compared patients who had angiographic CAD and myocardial infarction (n=5783) with those who had angiographic CAD but no myocardial infarction (n=3644). In the comparison of patients with angiographic CAD versus controls, we identified a novel locus, ADAMTS7 (p=4·98×10(-13)). In the comparison of patients with angiographic CAD who had myocardial infarction versus those with angiographic CAD but no myocardial infarction, we identified a novel association at the ABO locus (p=7·62×10(-9)). The ABO association was attributable to the glycotransferase-deficient enzyme that encodes the ABO blood group O phenotype previously proposed to protect against myocardial infarction. Our findings indicate that specific genetic predispositions promote the development of coronary atherosclerosis whereas others lead to myocardial infarction in the presence of coronary atherosclerosis. The relation to specific CAD phenotypes might modify how novel loci are applied in personalised risk assessment and used in the development of novel therapies for CAD. The PennCath and MedStar studies were supported by the Cardiovascular Institute of the University of Pennsylvania, by the MedStar Health Research Institute at Washington Hospital Center and by a research grant from GlaxoSmithKline. The funding and support for the other cohorts contributing to the paper are described in the webappendix. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Intravascular Ultrasound Classification of Plaque in Angiographic True Bifurcation Lesions of the Left Main Coronary Artery.

    PubMed

    Li, Li; Dash, Debabrata; Gai, Lu-Yue; Cao, Yun-Shan; Zhao, Qiang; Wang, Ya-Rong; Zhang, Yao-Jun; Zhang, Jun-Xia

    2016-07-05

    Accurately, characterizing plaques is critical for selecting the optimal intervention strategy for the left main coronary artery (LMCA) bifurcation. Coronary angiography cannot precisely assess the location or nature of plaques in bifurcation lesions. Few intravascular ultrasound (IVUS) classification scheme has been reported for angiographic imaging of true bifurcation lesions of the unprotected LMCA thus far. In addition, the plaque composition at the bifurcation has not been elucidated. This study aimed to detect plaque composition at LMCA bifurcation lesions by IVUS. Fifty-eight patients were recruited. The location, concentricity or eccentricity, site of maximum thickness, and composition of plaques of the distal LMCA, ostial left anterior descending (LAD) coronary artery and, left circumflex (LCX) coronary artery were assessed using IVUS and described using illustrative diagrams. True bifurcation lesions of the unprotected LMCA were classified into four types: Type A, with continuous involvement from the distal LMCA to the ostial LAD and the ostial LCX with eccentric plaques; Type B, with concentric plaques at the distal LMCA, eccentric plaques at the ostial LAD, and no plaques at the LCX; Type C, with continuous involvement from the distal LMCA to the ostial LCX, with eccentric plaques, and to the ostial LAD, with eccentric plaques; and Type D, with continuous involvement from the distal LMCA to the ostial LAD, with eccentric plaques, and to the ostial LCX, with concentric plaques. The carina was involved in only 3.5% of the plaques. A total of 51.7% of the plaques at the ostium of the LAD were soft, while 44.8% and 44.6% were fibrous in the distal LMCA and in the ostial LCX, respectively. We classified LMCA true bifurcation lesions into four types. The carina was always free from disease. Plaques at the ostial LAD tended to be soft, whereas those at the ostial LCX and the distal LMCA tended to be fibrous.

  16. Dietary intake of patients with angiographically defined coronary artery disease and that of healthy controls in Iran.

    PubMed

    Nazeminezhad, R; Tajfard, M; Latiff, L A; Mouhebati, M; Esmaeily, H; Ferns, G A A; Ghayour-Mobarhan, M; Rahimi, H R

    2014-01-01

    The aim of this study was to investigate the relationship between dietary intake and biomarkers of cardiovascular risk in individuals with and without angiographically defined coronary artery disease. Coronary angiography was undertaken in 445 individuals who were divided into those with significant disease (>50% occlusion) (Angio+ (n=273)) and those with <50% coronary artery occlusion (Angio- (n=172)). Apparently healthy, non-symptomatic individuals (n=443) were considered as the control group. Dietary intake was assessed using a 24-h dietary recall method and dietary analysis was performed using Diet Plan 6 software. Concentrations of starch, saturated fatty acids, polyunsaturated fatty acids, magnesium, iron and copper in the control group were less than those in the other groups (P<0.05), but after adjusting for total energy intake these differences were no longer apparent. The mean intake of protein, cholesterol, phosphorus, zinc, zinc/copper ratio, selenium, iodine, carotene, vitamin E, niacin, pantothene and pyridoxine was less in the control group compared with the other two groups (P<0.05), and the mean of sugar, fiber, transfatty acids, manganese, folate and vitamin C was higher in the control group than in other groups (P<0.05). Lipid profile values between the three groups did not differ significantly. These results indicate that the amount of intake of various nutrients can be considered as an independent risk factor for CAD. Further research on the relationship between CAD and nutrient intake, especially intake of essential micronutrients, is needed.

  17. Quantitative coronary plaque analysis predicts high-risk plaque morphology on coronary computed tomography angiography: results from the ROMICAT II trial.

    PubMed

    Liu, Ting; Maurovich-Horvat, Pál; Mayrhofer, Thomas; Puchner, Stefan B; Lu, Michael T; Ghemigian, Khristine; Kitslaar, Pieter H; Broersen, Alexander; Pursnani, Amit; Hoffmann, Udo; Ferencik, Maros

    2018-02-01

    Semi-automated software can provide quantitative assessment of atherosclerotic plaques on coronary CT angiography (CTA). The relationship between established qualitative high-risk plaque features and quantitative plaque measurements has not been studied. We analyzed the association between quantitative plaque measurements and qualitative high-risk plaque features on coronary CTA. We included 260 patients with plaque who underwent coronary CTA in the Rule Out Myocardial Infarction/Ischemia Using Computer Assisted Tomography (ROMICAT) II trial. Quantitative plaque assessment and qualitative plaque characterization were performed on a per coronary segment basis. Quantitative coronary plaque measurements included plaque volume, plaque burden, remodeling index, and diameter stenosis. In qualitative analysis, high-risk plaque was present if positive remodeling, low CT attenuation plaque, napkin-ring sign or spotty calcium were detected. Univariable and multivariable logistic regression analyses were performed to assess the association between quantitative and qualitative high-risk plaque assessment. Among 888 segments with coronary plaque, high-risk plaque was present in 391 (44.0%) segments by qualitative analysis. In quantitative analysis, segments with high-risk plaque had higher total plaque volume, low CT attenuation plaque volume, plaque burden and remodeling index. Quantitatively assessed low CT attenuation plaque volume (odds ratio 1.12 per 1 mm 3 , 95% CI 1.04-1.21), positive remodeling (odds ratio 1.25 per 0.1, 95% CI 1.10-1.41) and plaque burden (odds ratio 1.53 per 0.1, 95% CI 1.08-2.16) were associated with high-risk plaque. Quantitative coronary plaque characteristics (low CT attenuation plaque volume, positive remodeling and plaque burden) measured by semi-automated software correlated with qualitative assessment of high-risk plaque features.

  18. Prevalence and risk factors of premature coronary artery disease in patients undergoing coronary angiography in Kurdistan, Iraq.

    PubMed

    Mohammad, Ameen Mosa; Jehangeer, Hekmat Izzat; Shaikhow, Sabri Khalif

    2015-11-18

    Premature coronary artery disease (PCAD) seems to increase, particularly in developing countries. Given the lack of such studies in the country, this study examines the prevalence, associated cardiovascular risk factors, and coronary angiographic profile of the disease in Iraq. Data was collected from a total of 445 adult patients undergoing coronary angiography at Duhok Heart Center, Kurdistan in a period between March and September 2014. Patients were divided into PCAD (male <45 years and female < 55 years) and mature coronary artery disease (MCAD). The prevalence of the angiographically documented PCAD was 31 %. The PCAD had higher rates of hyperlipidemia (p = 0.04), positive family history of coronary artery disease (p = 0.002), type A lesions (p = 0.02), single vessel disease (p = 0.01) and medical treatment (p = 0.01) than the MCAD. Logistic regression model indicated that male sex (OR 3.38, C.I 1.96-7.22), smoking (OR 2.08, C.I 1.05-4.12), hypertension (OR 1.58, C.I 1.25-2.03), hyperlipidemia (OR 1.89, C.I 1.17-2.42) and positive family history of coronary artery disease (OR 2.62, C.I 1.38-9.54) were associated with the PCAD. Sensitivity analysis showed highest specificity (94.2 %) and positive predictive value (96.5 %) in patients with coronary stenosis >70 % compared to lesser obstruction. Premature coronary artery disease is alarming  in the country. Cardiovascular risk factors are clustered among them. But the angiographic profile and therapeutic options of PCAD are close to those reported from previous studies.

  19. Five-year clinical and angiographic follow-up after intracoronary iridium-192 radiation therapy.

    PubMed

    Condado, Jose A; Waksman, Ron; Saucedo, Jorge F; Bhargava, Balram; Lansky, Alexandra J; Calderas, Carlos; Gurdiel, Orlando; Gonzalez, Juan; Fadoul, Merche; Parra, Bogart; Iturria, Isabel; Amezaga, Bingen

    2002-01-01

    Ionizing gamma radiation has been shown to reduce neointimal formation and the incidence of restenosis after balloon angioplasty and stenting in clinical trials. However, the long-term effects of this therapy are unknown. The first cohort of patients to receive intracoronary gamma radiation after balloon angioplasty for the prevention of restenosis have completed a 5-year angiographic and clinical follow-up. The outcome of these patients is presented and discussed. Twenty-one patients with unstable angina (22 arteries) underwent standard balloon angioplasty. Intracoronary radiation therapy was performed immediately after the intervention using an Iridium-192 source wire hand-delivered to the angioplasty site. All patients were followed clinically and Quantitative Coronary Analysis (QCA) was performed at 6, 24, 36 and 60 months. Target lesion revascularization occurred in six lesions, three of which were total occlusions (two early within 30 days and one occurred at 2 years), and one patient had a myocardial infarction attributable to a nontarget vessel. Serial QCA detected a binary restenosis rate of 28.6% (n=6) at 6 months. The late loss (0.29 mm) and loss index (0.25) remained low at 2, 3 and 5 years. Angiographic complications included four aneurysms (two procedure related and two occurring within 3 months). At 2 years, only one aneurysm increased in size (46 vs. 27 mm(2)); and at 3 and 5 years, all aneurysms remained unchanged. No other angiographic complications were observed. The early clinical and angiographic effects of intracoronary gamma radiation were maintained at 5 years without further increase in the aneurysm formation or apparent new adverse effects related to the radiation therapy between 2 and 5 years.

  20. Clinical and angiographic characteristics of patients likely to have vulnerable plaques: analysis from the PROSPECT study.

    PubMed

    Bourantas, Christos V; Garcia-Garcia, Hector M; Farooq, Vasim; Maehara, Akiko; Xu, Ke; Généreux, Philippe; Diletti, Roberto; Muramatsu, Takashi; Fahy, Martin; Weisz, Giora; Stone, Gregg W; Serruys, Patrick W

    2013-12-01

    This study sought to determine the clinical and angiographic variables that would identify patients with high-risk "vulnerable" coronary plaques. In the PROSPECT (Providing Regional Observations to Study Predictors of Events in the Coronary Tree) study, in patients successfully treated for acute coronary syndrome (ACS), plaque composition, plaque burden, and minimal luminal area as detected by 3-vessel radiofrequency intravascular ultrasound (IVUS) imaging were associated with an increased risk of developing future events from untreated atherosclerotic lesions (vulnerable plaques). Whether baseline demographic and angiographic findings can be used to identify patients most likely to have vulnerable coronary plaques has not been examined. On the basis of 3-vessel radiofrequency IVUS imaging, patents in the PROSPECT trial were classified in 2 groups according to whether or not one or more untreated high-risk plaques were present, defined as having ≥2 high-risk features (a thin-cap fibroatheroma, plaque burden ≥70%, and/or minimal luminal area ≤4 mm(2)). The high-risk group (those with one or more high-risk lesions) had higher Framingham risk score (7.5 ± 3.4 vs. 6.9 ± 3.3; p = 0.04), more extensive coronary artery disease, and more nonculprit lesion-related cardiovascular events during the 3-year follow-up (hazard ratio: 2.63; 95% confidence interval: 1.62 to 3.66; p < 0.0001). However, demographic factors had poor discrimination in detecting high-risk patients (area under the curve 0.55), and discrimination was only slightly improved when angiographic variables were entered into the model (area under the curve 0.64). Clinical and angiographic characteristics had poor predictive accuracy in identifying patients with untreated high-risk plaques related to future adverse events. This finding highlights the potential value of comprehensive 3-vessel imaging assessment (either invasive or noninvasive) to evaluate plaque phenotype for more accurate risk

  1. Thrombolysis in myocardial infarction frame count in coronary arteries without visible atherosclerosis in coronary angiography of patients with stable coronary artery disease.

    PubMed

    Tacoy, Gulten A; Yazici, Guliz E; Kocaman, Sinan A; Ozdemir, Murat H

    2009-06-01

    To investigate the thrombolysis in myocardial infarction (TIMI) frame count (TFC) in the coronary arteries without visible atherosclerosis in coronary angiography of patients with stable coronary artery disease (CAD). Eighty-three patients (mean age 58+/-10, 31 [37%] males), who underwent coronary angiographic evaluation for stable angina in Gazi University, Ankara, Turkey, Cardiology clinic between 2006-2007 were enrolled. Forty patients with normal coronary arteries were defined as group I. Group II consisted of 43 patients, who have one normal coronary artery in the setting of stable CAD defined as stenoses 50% or greater in at least one major coronary artery. Coronary blood flow and microvascular perfusion was evaluated by TFC. In group II, the TFC of left anterior descending artery (LAD) in 15 patients, TFC of circumflex artery (CX) in 18 patient, and TFC of right coronary artery (RCA) in 10 patients were evaluated. In group II, the TFC of LAD (37+/-12 versus 29+/-12, p=0.015) and CX (22+/-8 versus 18+/-9, p=0.035) were significantly higher than those in group I. The TFC of RCA was similar between groups (17+/-9 versus 17+/-8, p=0.990). After the adjustment of the risk factors by multivariate regression analyses, the association between TFC and clinical characteristic was statistically non-significant. The TFC decreased in angiographically normal LAD and CX arteries in the setting of stable angina pectoris. The important predictor was CAD alone, irrespective of the clinical parameters.

  2. Multicenter AIDS Cohort Study Quantitative Coronary Plaque Progression Study: rationale and design.

    PubMed

    Nakanishi, Rine; Post, Wendy S; Osawa, Kazuhiro; Jayawardena, Eranthi; Kim, Michael; Sheidaee, Nasim; Nezarat, Negin; Rahmani, Sina; Kim, Nicholas; Hathiramani, Nicolai; Susarla, Shriraj; Palella, Frank; Witt, Mallory; Blaha, Michael J; Brown, Todd T; Kingsley, Lawrence; Haberlen, Sabina A; Dailing, Christopher; Budoff, Matthew J

    2018-01-01

    The association of HIV with coronary atherosclerosis has been established; however, the progression of coronary atherosclerosis over time among participants with HIV is not well known. The Multicenter AIDS Cohort Study Quantitative Coronary Plaque Progression Study is a large prospective multicenter study quantifying progression of coronary plaque assessed by serial coronary computed tomography angiography (CTA). HIV-infected and uninfected men who were enrolled in the Multicenter AIDS Cohort Study Cardiovascular Substudy were eligible to complete a follow-up contrast coronary CTA 3-6 years after baseline. We measured coronary plaque volume and characteristics (calcified and noncalcified plaque including fibrous, fibrous-fatty, and low attenuation) and vulnerable plaque among HIV-infected and uninfected men using semiautomated plaque software to investigate the progression of coronary atherosclerosis over time. We describe a novel, large prospective multicenter study investigating incidence, transition of characteristics, and progression in coronary atherosclerosis quantitatively assessed by serial coronary CTAs among HIV-infected and uninfected men.

  3. Patient-specific coronary blood supply territories for quantitative perfusion analysis

    PubMed Central

    Zakkaroff, Constantine; Biglands, John D.; Greenwood, John P.; Plein, Sven; Boyle, Roger D.; Radjenovic, Aleksandra; Magee, Derek R.

    2018-01-01

    Abstract Myocardial perfusion imaging, coupled with quantitative perfusion analysis, provides an important diagnostic tool for the identification of ischaemic heart disease caused by coronary stenoses. The accurate mapping between coronary anatomy and under-perfused areas of the myocardium is important for diagnosis and treatment. However, in the absence of the actual coronary anatomy during the reporting of perfusion images, areas of ischaemia are allocated to a coronary territory based on a population-derived 17-segment (American Heart Association) AHA model of coronary blood supply. This work presents a solution for the fusion of 2D Magnetic Resonance (MR) myocardial perfusion images and 3D MR angiography data with the aim to improve the detection of ischaemic heart disease. The key contribution of this work is a novel method for the mediated spatiotemporal registration of perfusion and angiography data and a novel method for the calculation of patient-specific coronary supply territories. The registration method uses 4D cardiac MR cine series spanning the complete cardiac cycle in order to overcome the under-constrained nature of non-rigid slice-to-volume perfusion-to-angiography registration. This is achieved by separating out the deformable registration problem and solving it through phase-to-phase registration of the cine series. The use of patient-specific blood supply territories in quantitative perfusion analysis (instead of the population-based model of coronary blood supply) has the potential of increasing the accuracy of perfusion analysis. Quantitative perfusion analysis diagnostic accuracy evaluation with patient-specific territories against the AHA model demonstrates the value of the mediated spatiotemporal registration in the context of ischaemic heart disease diagnosis. PMID:29392098

  4. Correlation of Admission Heart Rate With Angiographic and Clinical Outcomes in Patients With Right Coronary Artery ST-Segment Elevation Myocardial Infarction Undergoing Primary Percutaneous Coronary Intervention: HORIZONS-AMI (The Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction) Trial.

    PubMed

    Kosmidou, Ioanna; McAndrew, Thomas; Redfors, Björn; Embacher, Monica; Dizon, José M; Mehran, Roxana; Ben-Yehuda, Ori; Mintz, Gary S; Stone, Gregg W

    2017-07-19

    Bradycardia on presentation is frequently observed in patients with right coronary artery ST-segment elevation myocardial infarction, but it is largely unknown whether it predicts poor angiographic or clinical outcomes in that patient population. We sought to determine the prognostic implications of admission heart rate (AHR) in patients with ST-segment elevation myocardial infarction and a right coronary artery culprit lesion. We analyzed 1460 patients with ST-segment elevation myocardial infarction and a right coronary artery culprit lesion enrolled in the randomized HORIZONS-AMI (Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction) trial who underwent primary percutaneous coronary intervention. Patients presenting with high-grade atrioventricular block were excluded. Outcomes were examined according to AHR range (AHR <60, 61-79, 80-99, and ≥100 beats per minute). Baseline and procedural characteristics did not vary significantly with AHR except for a more frequent history of diabetes mellitus, longer symptom-to-balloon time, more frequent cardiogenic shock, and less frequent restoration of thrombolysis in myocardial infarction 3 flow in patients with admission tachycardia (AHR >100 beats per minute). Angiographic analysis showed no significant association between AHR and lesion location or complexity. On multivariate analysis, admission bradycardia (AHR <60 beats per minute) was not associated with increased 1-year mortality (hazard ratio 1.33; 95% CI 0.41-4.34, P =0.64) or major adverse cardiac events (hazard ratio 1.08; 95% CI 0.62-1.88, P =0.78), whereas admission tachycardia was a strong independent predictor of mortality (hazard ratio 5.02; 95% CI 1.95-12.88, P =0.0008) and major adverse cardiac events (hazard ratio 2.20; 95% CI 1.29-3.75, P =0.0004). In patients with ST-segment elevation myocardial infarction and a right coronary artery culprit lesion undergoing primary percutaneous coronary intervention, admission

  5. Fast virtual functional assessment of intermediate coronary lesions using routine angiographic data and blood flow simulation in humans: comparison with pressure wire - fractional flow reserve.

    PubMed

    Papafaklis, Michail I; Muramatsu, Takashi; Ishibashi, Yuki; Lakkas, Lampros S; Nakatani, Shimpei; Bourantas, Christos V; Ligthart, Jurgen; Onuma, Yoshinobu; Echavarria-Pinto, Mauro; Tsirka, Georgia; Kotsia, Anna; Nikas, Dimitrios N; Mogabgab, Owen; van Geuns, Robert-Jan; Naka, Katerina K; Fotiadis, Dimitrios I; Brilakis, Emmanouil S; Garcia-Garcia, Héctor M; Escaned, Javier; Zijlstra, Felix; Michalis, Lampros K; Serruys, Patrick W

    2014-09-01

    To develop a simplified approach of virtual functional assessment of coronary stenosis from routine angiographic data and test it against fractional flow reserve using a pressure wire (wire-FFR). Three-dimensional quantitative coronary angiography (3D-QCA) was performed in 139 vessels (120 patients) with intermediate lesions assessed by wire-FFR (reference standard: ≤0.80). The 3D-QCA models were processed with computational fluid dynamics (CFD) to calculate the lesion-specific pressure gradient (ΔP) and construct the ΔP-flow curve, from which the virtual functional assessment index (vFAI) was derived. The discriminatory power of vFAI for ischaemia- producing lesions was high (area under the receiver operator characteristic curve [AUC]: 92% [95% CI: 86-96%]). Diagnostic accuracy, sensitivity and specificity for the optimal vFAI cut-point (≤0.82) were 88%, 90% and 86%, respectively. Virtual-FAI demonstrated superior discrimination against 3D-QCA-derived % area stenosis (AUC: 78% [95% CI: 70- 84%]; p<0.0001 compared to vFAI). There was a close correlation (r=0.78, p<0.0001) and agreement of vFAI compared to wire-FFR (mean difference: -0.0039±0.085, p=0.59). We developed a fast and simple CFD-powered virtual haemodynamic assessment model using only routine angiography and without requiring any invasive physiology measurements/hyperaemia induction. Virtual-FAI showed a high diagnostic performance and incremental value to QCA for predicting wire-FFR; this "less invasive" approach could have important implications for patient management and cost.

  6. Comparison of plasma adiponectin & certain inflammatory markers in angiographically proven coronary artery disease patients with & without diabetes – A study from India

    PubMed Central

    Kumpatla, Satyavani; Karuppiah, Kirubakaran; Immaneni, Sathyamurthy; Muthukumaran, Parthiban; Krishnan, Jayanthi; Narayanamoorthy, Srinivasan Kanthallu; Viswanathan, Vijay

    2014-01-01

    Background & objectives: The association between adiponectin and risk of cardiovascular disease is well known. The aim of the present study was to evaluate adiponectin and certain inflammatory markers and to determine the correlations between them in angiographically proven coronary artery disease (CAD) in subjects with and without diabetes. Methods: A total of 180 subjects who underwent coronary angiography for symptoms suggestive of CAD were categorised into groups based on their diabetes and/or CAD status: group1 (non-diabetic non-CAD); group2 (non-diabetic CAD); group3 (diabetic non-CAD) and group4 (diabetic CAD). Adiponectin, tumour necrosis factor α (TNF-α) and soluble form of E-selectin (sE-selectin) were estimated using quantitative sandwich enzyme immunoassay and high sensitive C-reactive protein (hsCRP) by particle enhanced immunoturbidimetric method. Results: Adiponectin levels were significantly lower in subjects with either diabetes or CAD and were much lower in subjects who had both. hsCRP was elevated in CAD and diabetes but did not differ significantly between groups. sE-selectin and TNF-α levels were elevated in CAD. Adiponectin negatively correlated with age, glucose, sE-selectin, total and LDL cholesterol. hsCRP correlated with BMI, sE-selectin and urea. sE-selectin correlated with BMI, triglycerides and VLDL cholesterol, whereas TNF-α correlated with fasting plasma glucose. In the logistic regression analysis, adiponectin had a significant inverse association with CAD. sE-selectin and TNF-α also showed significant independent association with CAD. Interpretation & conclusions: Adiponectin and other inflammatory markers such as sE-selectin and TNF-α showed a significant association with CAD. Hence, early assessment of such markers can help to identify high risk patients, and to reduce the inflammatory component of diabetes and CAD. PMID:25109718

  7. Increased sensitivity of prolonged P-wave during exercise stress test in detection of angiographically documented coronary artery disease.

    PubMed

    Wsol, Agnieszka; Wydra, Wioletta; Chmielewski, Marek; Swiatowiec, Andrzej; Kuch, Marek

    2017-01-01

    A retrospective study was designed to investigate P-wave duration changes in exercise stress test (EST) for the prediction of angiographically documented substantial coronary artery disease (CAD). We analyzed 265 cases of patients, who underwent EST and subsequently coronary angiography. Analysis of P-wave duration was performed in leads II, V5 at rest, and in the recovery period. The sensitivity and specificity for the isolated ST-segment depression were only 31% and 76%, respectively. The combination of ST-depression with other exercise-induced clinical and electrocardio-graphic abnormalities (chest pain, ventricular arrhythmia, hypotension, left bundle branch block) was characterized by 41% sensitivity and 69% specificity. The combination of abnormal recovery P-wave duration (≥ 120 ms) with ST-depression and other exercise-induced abnormalities had 83% sensitivity but only 20% specificity. Combined analysis of increased delta P-wave duration, ST-depression and other exercise-induced abnormalities had 69% sensitivity and 42% specificity. Sensitivity and specificity of the increase in delta P-wave duration for left CAD was 69% and 47%, respectively, and for 3-vessel CAD 70% and 50%, respectively. The presence of arterial hypertension negatively influenced the prog-nostic value of P-wave changes in the stress test. The results of the study show that an addition of P-wave duration changes assessment to ST-depression analysis and other exercise-induced abnormalities increase sensitivity of EST, especially for left CAD and 3-vessel coronary disease. We have also provided evidence for the negative influence of the presence of arterial hypertension on the predictive value of P-wave changes in the stress test. (Cardiol J 2017; 24, 2: 159-166).

  8. Dual-source CT imaging to plan transcatheter aortic valve replacement: accuracy for diagnosis of obstructive coronary artery disease.

    PubMed

    Harris, Brett S; De Cecco, Carlo N; Schoepf, U Joseph; Steinberg, Daniel H; Bayer, Richard R; Krazinski, Aleksander W; Dyer, Kevin T; Sandhu, Monique K; Zile, Michael R; Meinel, Felix G

    2015-04-01

    To assess the accuracy of computed tomographic (CT) examinations performed for the purpose of transcatheter aortic valve replacement (TAVR) planning to diagnose obstructive coronary artery disease (CAD). With institutional review board approval, waivers of informed consent, and in compliance with HIPAA, 100 consecutive TAVR candidates (61 men, mean age 79.6 years ± 9.9) who underwent both TAVR planning CT (with a dual-source CT system) and coronary catheter (CC) angiographic imaging were retrospectively analyzed. At both modalities, the presence of stenosis in the native coronary arteries was assessed. Additionally, all coronary bypass grafts were rated as patent or occluded. With CC angiographic imaging as the reference standard, the accuracy of CT for lesion detection on a per-vessel and per-patient basis was calculated. The accuracy of CT for the assessment of graft patency was also analyzed. For per-vessel and per-patient analysis for the detection of stenosis that was 50% or more in the native coronary arteries, CT imaging had, respectively, 94.4% and 98.6% sensitivity, 68.4% and 55.6% specificity, 94.7% and 93.8% negative predictive value (NPV), and 67.0% and 85.7% positive predictive value. Per-patient sensitivity of stenosis 50% or greater with CT for greater than 70% stenosis at CC angiographic imaging was 100%. All 12 vessels in which percutaneous coronary intervention was performed were correctly identified as demonstrating stenosis 50% or greater with CT. There was agreement between CT and CC angiographic imaging regarding graft patency in 114 of 115 grafts identified with CC angiographic imaging. TAVR planning CT has high sensitivity and NPV in excluding obstructive CAD. An additional preprocedural CC angiographic examination may not be required in TAVR candidates with a CT examination that does not show obstructive CAD. © RSNA, 2014 Online supplemental material is available for this article.

  9. Angiographic validation of the American College of Cardiology Foundation-the Society of Thoracic Surgeons Collaboration on the Comparative Effectiveness of Revascularization Strategies study.

    PubMed

    Chakrabarti, Anjan K; Grau-Sepulveda, Maria V; O'Brien, Sean; Abueg, Cassandra; Ponirakis, Angelo; Delong, Elizabeth; Peterson, Eric; Klein, Lloyd W; Garratt, Kirk N; Weintraub, William S; Gibson, C Michael

    2014-02-01

    The goal of this study was to compare angiographic interpretation of coronary arteriograms by sites in community practice versus those made by a centralized angiographic core laboratory. The study population consisted of 2013 American College of Cardiology-National Cardiovascular Data Registry (ACC-NCDR) records with 2- and 3- vessel coronary disease from 54 sites in 2004 to 2007. The primary analysis compared Registry (NCDR)-defined 2- and 3-vessel disease versus those from an angiographic core laboratory analysis. Vessel-level kappa coefficients suggested moderate agreement between NCDR and core laboratory analysis, ranging from kappa=0.39 (95% confidence intervals, 0.32-0.45) for the left anterior descending artery to kappa=0.59 (95% confidence intervals, 0.55-0.64) for the right coronary artery. Overall, 6.3% (n=127 out of 2013) of those patients identified with multivessel disease at NCDR sites had had 0- or 1-vessel disease by core laboratory reading. There was no directional bias with regard to overcall, that is, 12.3% of cases read as 3-vessel disease by the sites were read as <3-vessel disease by the core laboratory, and 13.9% of core laboratory 3-vessel cases were read as <3-vessel by the sites. For a subset of patients with left main coronary disease, registry overcall was not linked to increased rates of mortality or myocardial infarction. There was only modest agreement between angiographic readings in clinical practice and those from an independent core laboratory. Further study will be needed because the implications for patient management are uncertain.

  10. Diagnostic accuracy of stress perfusion CMR in comparison with quantitative coronary angiography: fully quantitative, semiquantitative, and qualitative assessment.

    PubMed

    Mordini, Federico E; Haddad, Tariq; Hsu, Li-Yueh; Kellman, Peter; Lowrey, Tracy B; Aletras, Anthony H; Bandettini, W Patricia; Arai, Andrew E

    2014-01-01

    This study's primary objective was to determine the sensitivity, specificity, and accuracy of fully quantitative stress perfusion cardiac magnetic resonance (CMR) versus a reference standard of quantitative coronary angiography. We hypothesized that fully quantitative analysis of stress perfusion CMR would have high diagnostic accuracy for identifying significant coronary artery stenosis and exceed the accuracy of semiquantitative measures of perfusion and qualitative interpretation. Relatively few studies apply fully quantitative CMR perfusion measures to patients with coronary disease and comparisons to semiquantitative and qualitative methods are limited. Dual bolus dipyridamole stress perfusion CMR exams were performed in 67 patients with clinical indications for assessment of myocardial ischemia. Stress perfusion images alone were analyzed with a fully quantitative perfusion (QP) method and 3 semiquantitative methods including contrast enhancement ratio, upslope index, and upslope integral. Comprehensive exams (cine imaging, stress/rest perfusion, late gadolinium enhancement) were analyzed qualitatively with 2 methods including the Duke algorithm and standard clinical interpretation. A 70% or greater stenosis by quantitative coronary angiography was considered abnormal. The optimum diagnostic threshold for QP determined by receiver-operating characteristic curve occurred when endocardial flow decreased to <50% of mean epicardial flow, which yielded a sensitivity of 87% and specificity of 93%. The area under the curve for QP was 92%, which was superior to semiquantitative methods: contrast enhancement ratio: 78%; upslope index: 82%; and upslope integral: 75% (p = 0.011, p = 0.019, p = 0.004 vs. QP, respectively). Area under the curve for QP was also superior to qualitative methods: Duke algorithm: 70%; and clinical interpretation: 78% (p < 0.001 and p < 0.001 vs. QP, respectively). Fully quantitative stress perfusion CMR has high diagnostic accuracy for

  11. Intravascular Ultrasound to Guide Percutaneous Coronary Interventions

    PubMed Central

    2006-01-01

    coronary angiography (the imaging tool used to guide stent placement) has been shown to be inaccurate in assessing optimal stent placement, and IVUS can provide better views of the vessel lumen, the clinical utility of IVUS as an imaging tool adjunctive to coronary angiography in coronary intervention procedures has been explored in clinical studies. Method A systematic review was conducted to answer the following questions: What are the procedure-related complications associated with IVUS? Does IVUS used in conjunction with angiography to guide percutaneous interventions improve patient outcomes compared to angiographic guidance without IVUS? Who would benefit most in terms of clinical outcomes from the use of IVUS adjunctive to coronary angiography in guiding PCIs? What is the effectiveness of IVUS guidance in the context of drug-eluting stents? What is the cost-effectiveness ratio and budget impact of adjunctive IVUS in PCIs in Ontario? A systematic search of databases OVID MEDLINE, EMBASE, MEDLINE In-Process & Other Non-Indexed Citations, The Cochrane Library, and the International Agency for Health Technology Assessment (INAHTA) database for the period beginning in May 2001 until the day of the search, November 4, 2005 yielded 2 systematic reviews, 1 meta-analysis, 6 randomized controlled trials, and 2 non-randomized studies on left main coronary arteries. The quality of the studies ranged from moderate to high. These reports were combined with reports from a previous systematic review for analysis. In addition to qualitative synthesis, pooled analyses of data from randomized controlled studies using a random effect model in the Cochrane Review Manager 4.2 software were conducted when possible. Findings of Literature Review & Analysis Safety Intravascular ultrasound appears to be a safe tool when used in coronary interventions. Periprocedural complications associated with the use of IVUS in coronary interventions ranged from 0.5% in the largest study to 4%. Coronary

  12. Automatic vasculature identification in coronary angiograms by adaptive geometrical tracking.

    PubMed

    Xiao, Ruoxiu; Yang, Jian; Goyal, Mahima; Liu, Yue; Wang, Yongtian

    2013-01-01

    As the uneven distribution of contrast agents and the perspective projection principle of X-ray, the vasculatures in angiographic image are with low contrast and are generally superposed with other organic tissues; therefore, it is very difficult to identify the vasculature and quantitatively estimate the blood flow directly from angiographic images. In this paper, we propose a fully automatic algorithm named adaptive geometrical vessel tracking (AGVT) for coronary artery identification in X-ray angiograms. Initially, the ridge enhancement (RE) image is obtained utilizing multiscale Hessian information. Then, automatic initialization procedures including seed points detection, and initial directions determination are performed on the RE image. The extracted ridge points can be adjusted to the geometrical centerline points adaptively through diameter estimation. Bifurcations are identified by discriminating connecting relationship of the tracked ridge points. Finally, all the tracked centerlines are merged and smoothed by classifying the connecting components on the vascular structures. Synthetic angiographic images and clinical angiograms are used to evaluate the performance of the proposed algorithm. The proposed algorithm is compared with other two vascular tracking techniques in terms of the efficiency and accuracy, which demonstrate successful applications of the proposed segmentation and extraction scheme in vasculature identification.

  13. History of vasomotor symptoms, extent of coronary artery disease, and clinical outcomes after acute coronary syndrome in postmenopausal women.

    PubMed

    Ferri, Luca A; Morici, Nuccia; Bassanelli, Giorgio; Franco, Nicoletta; Misuraca, Leonardo; Lenatti, Laura; Jacono, Emilia Lo; Leuzzi, Chiara; Corrada, Elena; Aranzulla, Tiziana C; Colombo, Delia; Cagnacci, Angelo; Prati, Francesco; Savonitto, Stefano

    2018-06-01

    Vasomotor symptoms (VMS) during menopausal transition have been linked to a higher burden of cardiovascular risk factors, subclinical vascular disease, and subsequent vascular events. We aim to investigate the association of VMS with the extent of coronary disease and their prognostic role after an acute coronary syndrome. The Ladies Acute Coronary Syndrome study enrolled consecutive women with an acute coronary syndrome undergoing coronary angiography. A menopause questionnaire was administered during admission. Angiographic data underwent corelab analysis. Six out of 10 enrolling centers participated in 1-year follow-up. Outcome data included the composite endpoint of all-cause mortality, recurrent myocardial infarction, stroke, and rehospitalization for cardiovascular causes within 1 year. Of the 415 women with available angiographic corelab analysis, 373 (90%) had complete 1-year follow-up. Among them, 202 women had had VMS during menopausal transition. These women had the same mean age at menopause as those without VMS (50 years in both groups), but were younger at presentation (median age 71 vs 76 years; P < 0.001), despite a more favorable cardiovascular risk profile (chronic kidney dysfunction 4.5% vs 15.9%; P = 0.001; prior cerebrovascular disease 4.5 vs 12.2%; P = 0.018). Extent of coronary disease at angiography was similar between groups (mean Gensini score 49 vs 51; P = 0.6; mean SYNTAX score 14 vs 16; P = 0.3). Overall cardiovascular events at 1 year did not differ between groups (19% vs 22%; P = 0.5). In postmenopausal women with an acute coronary syndrome, a history of VMS was associated with younger age at presentation, despite a lower vascular disease burden and similar angiographically defined coronary disease as compared with women without VMS. No difference could be found in terms of overall clinical outcomes. These results should be interpreted cautiously as all analyses were unadjusted and did not account for risk

  14. Timing of Hormone Therapy, Type of Menopause, and Coronary Disease in Women: Data from the NHLBI-sponsored Women’s Ischemia Syndrome Evaluation (WISE)

    PubMed Central

    Shufelt, Chrisandra; Johnson, B. Delia; Berga, Sarah L.; Braunstein, Glenn D.; Reis, Steven E.; Bittner, Vera; Yang, YuChing; Pepine, Carl J.; Sharaf, Barry L.; Sopko, George; Kelsey, Sheryl F.; Merz, C. Noel Bairey

    2011-01-01

    Objective To assess the relationship of timing of hormone therapy (HT) use with angiographic coronary artery disease (CAD) and cardiovascular disease (CVD) events in women with natural versus surgical menopause. Methods We studied 654 postmenopausal women undergoing coronary angiography for evaluation of suspected ischemia. Timing and type of menopause, HT use, and quantitative angiographic evaluations were obtained at baseline, and the women were followed for a median of 6 years for CVD events. Results Ever users of HT had a significantly lower prevalence of obstructive CAD compared to never users (age-adjusted OR=0.41 [0.28, 0.60]). Naturally menopausal women initiating HT at age <55 years had lower CAD severity compared to never users (age-adjusted beta [SE] = −6.23 [1.50], p<0.0001) while those initiating HT age ≥55 years did not differ statistically from never users (−3.34 [2.13], p=0.12). HT use remained a significant predictor of obstructive CAD when adjusting for a “healthy user” model OR 0.44 [0.30, 0.73] (p=0.002). An association between HT and fewer CVD events was observed only in the natural menopause group (HR [95%CI] = 0.60[0.41, 0.88], p=0.009) but became non-significant when adjusting for presence or severity of obstructive CAD. Conclusions Using quantitative measurements of timing and type of menopause and HT use, earlier initiation of HT was associated with less angiographic CAD in women with natural but not surgical menopause. Our data suggest that the effect of HT use on reduced cardiovascular event rates is mediated by the presence or absence of angiographic obstructive atherosclerosis. PMID:21532511

  15. Burden of hospital admission and repeat angiography in angina pectoris patients with and without coronary artery disease: a registry-based cohort study.

    PubMed

    Jespersen, Lasse; Abildstrom, Steen Z; Hvelplund, Anders; Madsen, Jan K; Galatius, Soren; Pedersen, Frants; Hojberg, Soren; Prescott, Eva

    2014-01-01

    To evaluate risk of hospitalization due to cardiovascular disease (CVD) and repeat coronary angiography (CAG) in stable angina pectoris (SAP) with no obstructive coronary artery disease (CAD) versus obstructive CAD, and asymptomatic reference individuals. We followed 11,223 patients with no prior CVD having a first-time CAG in 1998-2009 due to SAP symptoms and 5,695 asymptomatic reference individuals from the Copenhagen City Heart Study through registry linkage for 7.8 years (median). In recurrent event survival analysis, patients with SAP had 3-4-fold higher risk of hospitalization for CVD irrespective of CAG findings and cardiovascular comorbidity. Multivariable adjusted hazard ratios(95%CI) for patients with angiographically normal coronary arteries was 3.0(2.5-3.5), for angiographically diffuse non-obstructive CAD 3.9(3.3-4.6) and for 1-3-vessel disease 3.6-4.1(range)(all P<0.001). Mean accumulated hospitalization time was 3.5(3.0-4.0)(days/10 years follow-up) in reference individuals and 4.5(3.8-5.2)/7.0(5.4-8.6)/6.7(5.2-8.1)/6.1(5.2-7.4)/8.6(6.6-10.7) in patients with angiographically normal coronary arteries/angiographically diffuse non-obstructive CAD/1-, 2-, and 3-vessel disease, respectively (all P<0.05, age-adjusted). SAP symptoms predicted repeat CAG with multivariable adjusted hazard ratios for patients with angiographically normal coronary arteries being 2.3(1.9-2.9), for angiographically diffuse non-obstructive CAD 5.5(4.4-6.8) and for obstructive CAD 6.6-9.4(range)(all P<0.001). Patients with SAP symptoms and angiographically normal coronary arteries or angiographically diffuse non-obstructive CAD suffer from considerably greater CVD burdens in terms of hospitalization for CVD and repeat CAG compared with asymptomatic reference individuals even after adjustment for cardiac risk factors and exclusion of cardiovascular comorbidity as cause. Contrary to common perception, excluding obstructive CAD by CAG in such patients does not ensure a benign

  16. Angiographic Validation of the American College of Cardiology Foundation–The Society of Thoracic Surgeons Collaboration on the Comparative Effectiveness of Revascularization Strategies Study

    PubMed Central

    Chakrabarti, Anjan K.; Grau-Sepulveda, Maria V.; O’Brien, Sean; Abueg, Cassandra; Ponirakis, Angelo; Delong, Elizabeth; Peterson, Eric; Klein, Lloyd W.; Garratt, Kirk N.; Weintraub, William S.; Gibson, C. Michael

    2017-01-01

    Background The goal of this study was to compare angiographic interpretation of coronary arteriograms by sites in community practice versus those made by a centralized angiographic core laboratory. Methods and Results The study population consisted of 2013 American College of Cardiology–National Cardiovascular Data Registry (ACC–NCDR) records with 2- and 3- vessel coronary disease from 54 sites in 2004 to 2007. The primary analysis compared Registry (NCDR)-defined 2- and 3-vessel disease versus those from an angiographic core laboratory analysis. Vessel-level kappa coefficients suggested moderate agreement between NCDR and core laboratory analysis, ranging from kappa=0.39 (95% confidence intervals, 0.32–0.45) for the left anterior descending artery to kappa=0.59 (95% confidence intervals, 0.55–0.64) for the right coronary artery. Overall, 6.3% (n=127 out of 2013) of those patients identified with multivessel disease at NCDR sites had had 0- or 1-vessel disease by core laboratory reading. There was no directional bias with regard to overcall, that is, 12.3% of cases read as 3-vessel disease by the sites were read as <3-vessel disease by the core laboratory, and 13.9% of core laboratory 3-vessel cases were read as <3-vessel by the sites. For a subset of patients with left main coronary disease, registry overcall was not linked to increased rates of mortality or myocardial infarction. Conclusions There was only modest agreement between angiographic readings in clinical practice and those from an independent core laboratory. Further study will be needed because the implications for patient management are uncertain. PMID:24496239

  17. Baseline Characteristics and Prescription Patterns of Standard Drugs in Patients with Angiographically Determined Coronary Artery Disease and Renal Failure (CAD-REF Registry)

    PubMed Central

    Reinecke, Holger; Breithardt, Günter; Engelbertz, Christiane; Schmieder, Roland E.; Fobker, Manfred; Pinnschmidt, Hans O.; Schmitz, Boris; Bruland, Philipp; Wegscheider, Karl; Pavenstädt, Hermann; Brand, Eva

    2016-01-01

    Background Chronic kidney disease (CKD) is strongly associated with coronary artery disease (CAD). We established a prospective observational nationwide multicenter registry to evaluate current treatment and outcomes in patients with both CKD and angiographically documented CAD. Methods In 32 cardiological centers 3,352 CAD patients with ≥50% stenosis in at least one coronary artery were enrolled and classified according to their estimated glomerular filtration rate and proteinuria into one of five stages of CKD or as a control group. Results 2,723 (81.2%) consecutively enrolled patients suffered from CKD. Compared to controls, CKD patients had a higher prevalence of diabetes, hypertension, peripheral artery diseases, heart failure, and valvular heart disease (each p<0.001). Myocardial infarctions (p = 0.02), coronary bypass grafting, valve replacements and pacemaker implantations had been recorded more frequently (each p<0.001). With advanced CKD, the number of diseased coronary vessels and the proportion of patients with reduced left ventricular ejection fraction (LVEF) increased significantly (both p<0.001). Percutaneous coronary interventions were performed less frequently (p<0.001) while coronary bypass grafting was recommended more often (p = 0.04) with advanced CKD. With regard to standard drugs in CAD treatment, prescriptions were higher in our registry than in previous reports, but beta-blockers (p = 0.008), and angiotensin-converting-enzyme inhibitors and/or angiotensin-receptor blockers (p<0.001) were given less often in higher CKD stages. In contrast, in the subgroup of patients with moderately to severely reduced LVEF the prescription rates did not differ between CKD stages. In-hospital mortality increased stepwise with each CKD stage (p = 0.02). Conclusions In line with other studies comprising CKD cohorts, patients’ morbidity and in-hospital mortality increased with the degree of renal impairment. Although cardiologists’ drug prescription rates

  18. Topographic association of angioscopic yellow plaques with coronary atherosclerotic plaque: assessment with quantitative colorimetry in human coronary artery autopsy specimens.

    PubMed

    Ishibashi, Fumiyuki; Lisauskas, Jennifer B; Kawamura, Akio; Waxman, Sergio

    2008-01-01

    Yellow plaques seen during coronary angioscopy are thought to be the surrogates for superficial intimal lipids in coronary plaque. Given diffuse and heterogeneous nature of atherosclerosis, yellow plaques in coronaries may be seen as several yellow spots on diffuse coronary plaque. We examined the topographic association of yellow plaques with coronary plaque. In 40 non-severely stenotic ex-vivo coronary segments (average length: 52.2 +/- 3.1 mm), yellow plaques were examined by angioscopy with quantitative colorimetry. The segments were cut perpendicular to the long axis of the vessel at 2 mm intervals, and 1045 slides with 5 microm thick tissue for whole segments were prepared. To construct the plaque surface, each tissue slice was considered to be representative of the adjacent 2 mm. The circumference of the lumen and the lumen border of plaque were measured in each slide, and the plaque surface region was constructed. Coronary plaque was in 37 (93%) of 40 segments, and consisted of a single mass [39.9 +/- 3.9 (0-100) mm, 311.3 +/- 47.4 (0.0-1336.2) mm2]. In 30 (75%) segments, multiple (2-9) yellow plaques were detected on a mass of coronary plaque. The number of yellow plaques correlated positively with coronary plaque surface area (r = 0.77, P < 0.0001). Yellow plaques in coronaries detected by angioscopy with quantitative colorimetry, some of them are associated with lipid cores underneath thin fibrous caps, may be used to assess the extent of coronary plaque. Further research using angioscopy could be of value to study the association of high-risk coronaries with acute coronary syndromes.

  19. Agreement between clinical estimation and a new quantitative analysis by Photoshop software in fundus and angiographic image variables.

    PubMed

    Ramezani, Alireza; Ahmadieh, Hamid; Azarmina, Mohsen; Soheilian, Masoud; Dehghan, Mohammad H; Mohebbi, Mohammad R

    2009-12-01

    To evaluate the validity of a new method for the quantitative analysis of fundus or angiographic images using Photoshop 7.0 (Adobe, USA) software by comparing with clinical evaluation. Four hundred and eighteen fundus and angiographic images of diabetic patients were evaluated by three retina specialists and then by computing using Photoshop 7.0 software. Four variables were selected for comparison: amount of hard exudates (HE) on color pictures, amount of HE on red-free pictures, severity of leakage, and the size of the foveal avascular zone (FAZ). The coefficient of agreement (Kappa) between the two methods in the amount of HE on color and red-free photographs were 85% (0.69) and 79% (0.59), respectively. The agreement for severity of leakage was 72% (0.46). In the two methods for the evaluation of the FAZ size using the magic and lasso software tools, the agreement was 54% (0.09) and 89% (0.77), respectively. Agreement in the estimation of the FAZ size by the lasso magnetic tool was excellent and was almost as good in the quantification of HE on color and on red-free images. Considering the agreement of this new technique for the measurement of variables in fundus images using Photoshop software with the clinical evaluation, this method seems to have sufficient validity to be used for the quantitative analysis of HE, leakage, and FAZ size on the angiograms of diabetic patients.

  20. Assessment of coronary artery stenosis pressure gradient by quantitative coronary arteriography in patients with coronary artery disease.

    PubMed

    Atar, D; Ramanujam, P S; Saunamäki, K; Haunsø, S

    1994-01-01

    The aim of the study described here was to correlate coronary artery (CA) stenosis pressure gradients calculated by quantitative coronary arteriography (QCA) to invasively measured transstenotic pressure drops in patients with anginal symptoms and with known or suspected coronary artery disease. Furthermore, the known mathematical models are improved by introducing (1) pressure catheter-corrected minimal stenosis area, (2) modification of flow assumptions, and (3) stenosis exit angle. Included in the study were 45 patients with 61 stenoses. The visually estimated CA lesion severity in these non-complex stenoses was in the equivocal range of 40-70%. All measurements were performed after intracoronary administration of nifedipine and nitroglycerin. Stenosis dimensions were assessed from magnified cinefilms, using hand-held calipers. Highly significant overall correlation was found between measured and calculated pressure gradients with correction for the impact of the intracoronary catheter (P < 0.00001, r = 0.84). In particular, a substantial number of stenoses with haemodynamically-insignificant pressure gradients were identified by hydrodynamic calculations. In conclusion, the great majority of the coronary artery stenoses could be classified reliably by QCA as being haemodynamically insignificant or significant, respectively.

  1. Quantitative evaluation improves specificity of myocardial perfusion SPECT in the assessment of functionally significant intermediate coronary artery stenoses: a comparative study with fractional flow reserve measurements.

    PubMed

    Sahiner, Ilgin; Akdemir, Umit O; Kocaman, Sinan A; Sahinarslan, Asife; Timurkaynak, Timur; Unlu, Mustafa

    2013-02-01

    Myocardial perfusion SPECT (MPS) is a noninvasive method commonly used for assessment of the hemodynamic significance of intermediate coronary stenoses. Fractional flow reserve (FFR) measurement is a well-validated invasive method used for the evaluation of intermediate stenoses. We aimed to determine the association between MPS and FFR findings in intermediate degree stenoses and evaluate the added value of quantification in MPS. Fifty-eight patients who underwent intracoronary pressure measurement in the catheterization laboratory to assess the physiological significance of intermediate (40-70%) left anterior descending (LAD) artery lesions, and who also underwent stress myocardial perfusion SPECT either for the assessment of an intermediate stenosis or for suspected coronary artery disease were analyzed retrospectively in the study. Quantitative analysis was performed using the 4DMSPECT program, with visual assessment performed by two experienced nuclear medicine physicians blinded to the angiographic findings. Summed stress scores (SSS) and summed difference scores (SDS) in the LAD artery territory according to the 20 segment model were calculated. A summed stress score of ≥ 3 and an SDS of ≥ 2 were assumed as pathologic, indicating significance of the lesion; a cutoff value of 0.75 was used to define abnormal FFR. Both visual and quantitative assessment results were compared with FFR using Chi-square (χ²) test. The mean time interval between two studies was 13 ± 11 days. FFR was normal in 45 and abnormal in 13 patients. Considering the FFR results as the gold standard method for assessing the significance of the lesion, the sensitivity and specificity of quantitative analysis determining the abnormal flow reserve were 85 and 84%, respectively, while visual analysis had a sensitivity of 77% and a specificity of 51%. There was a good agreement between the observers (κ = 0.856). Summed stress and difference scores demonstrated moderate inverse

  2. Impact of perioperative myocardial infarction on angiographic and clinical outcomes following coronary artery bypass grafting (from PRoject of Ex-vivo Vein graft ENgineering via Transfection [PREVENT] IV).

    PubMed

    Yau, James M; Alexander, John H; Hafley, Gail; Mahaffey, Kenneth W; Mack, Michael J; Kouchoukos, Nicholas; Goyal, Abhinav; Peterson, Eric D; Gibson, C Michael; Califf, Robert M; Harrington, Robert A; Ferguson, T Bruce

    2008-09-01

    Myocardial infarction (MI) after coronary artery bypass grafting (CABG) is associated with significant morbidity and mortality. Frequency, management, mechanisms, and angiographic and clinical outcomes associated with perioperative MI remain poorly understood. PREVENT IV was a multicenter, randomized, placebo-controlled trial of edifoligide in 3,014 patients undergoing CABG. Angiographic and 2-year clinical follow-up were complete for 1,920 and 2,956 patients, respectively. Perioperative MI was defined as creatinine kinase-MB increase >or=10 times the upper limit of normal or >or=5 times the upper limit of normal with new 30-ms Q waves within 24 hours of surgery. Baseline characteristics, in-hospital management, and angiographic and clinical outcomes of patients with and without perioperative MI were compared. Perioperative MI occurred in 294 patients (9.8%). Patients with perioperative MI had longer surgery (250 vs 230 minutes; p <0.001), more on-pump surgery (83% vs 78%; p = 0.048), and worse target-artery quality (p <0.001). Patients with perioperative MI more frequently underwent angiography within 30 days of enrollment (1.7% vs 0.6%; p = 0.021). One-year angiographic vein graft failure occurred in 62.4% of patients with and 43.8% of patients without perioperative MI (p <0.001). Two-year composite clinical outcome (death, MI, or revascularization) was worse in patients with perioperative MI before (19.4% vs 15.2%; p = 0.039) and after (hazard ratio 1.33, 95% confidence interval 1.00 to 1.76, p = 0.046) adjusting for differences in significant predictors. In conclusion, perioperative MI was relatively common, was associated with worse outcomes, and mechanisms other than vein graft failure accounted for a substantial proportion of these MIs. Further research is needed into the prevention and treatment of perioperative MI in patients undergoing CABG.

  3. Induced coronary spasm without electrocardiographic signs or symptoms of myocardial ischemia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cipriano, P.R.

    1983-03-01

    Angiographic studies have shown that coronary artery spasm can be induced with ergonovine maleate. Coronary artery spasm induced by ergonovine maleate in these studies was nearly always accompanied by chest pain and electrocardiographic changes of myocardial ischemia. This report demonstrates that coronary artery spasm induced by ergonovine maleate may be diagnosed by angiography in the absence of these signs or symptoms.

  4. Combining clinical and angiographic variables for estimating risk of target lesion revascularization after drug eluting stent placement.

    PubMed

    Stolker, Joshua M; Cohen, David J; Kennedy, Kevin F; Pencina, Michael J; Arnold, Suzanne V; Kleiman, Neal S; Spertus, John A

    Drug-eluting stents (DES) reduce restenosis but require prolonged antiplatelet therapy, when compared with bare metal stents. Ideally, the patient should be involved in this risk:benefit assessment prior to selecting DES, to maximize the benefits and cost-effectiveness of care, and to improve medication adherence. However, accurate estimation of restenosis risk may require angiographic factors identified at cardiac catheterization. In a large PCI registry, we used logistic regression to identify clinical and angiographic predictors of clinically-driven target lesion revascularization (TLR) over the first year after stent placement. Discrimination c-statistic and integrated discrimination improvement (IDI) were used to calculate the incremental utility of angiographic variables when added to clinical predictors. Of 8501 PCI patients, TLR occurred in 4.5%. After adjusting for DES use, clinical TLR predictors were younger age, female sex, diabetes, prior PCI, and prior bypass surgery (model c-statistic 0.630). Angiographic predictors were vein graft PCI, in-stent restenosis lesion, longer stent length, and smaller stent diameter (c-statistic 0.650). After adding angiographic factors to the clinical model, c-statistic improved to 0.680 and the average separation in TLR risk among patients with and without TLR improved by 1% (IDI=0.010, 95% CI 0.009-0.014), primarily driven by those experiencing TLR (from 5.9% to 6.9% absolute risk). Among unselected PCI patients, the incidence of clinically-indicated TLR is <5% at 1-year, and standard clinical variables only moderately discriminate who will and will not experience TLR. Angiographic variables significantly improve TLR risk assessment, suggesting that stent selection may be best performed after coronary anatomy has been delineated. Although several recent studies have challenged traditional expectations regarding the duration of dual antiplatelet therapy, current guidelines recommend at least 6 to 12months of treatment

  5. Timing of hormone therapy, type of menopause, and coronary disease in women: data from the National Heart, Lung, and Blood Institute-sponsored Women's Ischemia Syndrome Evaluation.

    PubMed

    Shufelt, Chrisandra L; Johnson, B Delia; Berga, Sarah L; Braunstein, Glenn D; Reis, Steven E; Bittner, Vera; Yang, YuChing; Pepine, Carl J; Sharaf, Barry L; Sopko, George; Kelsey, Sheryl F; Merz, C Noel Bairey

    2011-09-01

    The aim of this study was to assess the relationship of the timing of hormone therapy (HT) use with angiographic coronary artery disease (CAD) and cardiovascular disease (CVD) events in women with natural versus surgical menopause. We studied 654 postmenopausal women undergoing coronary angiography for the evaluation of suspected ischemia. Timing and type of menopause, HT use, and quantitative angiographic evaluations were obtained at baseline, and the women were followed for a median of 6 years for CVD events. Ever users of HT had a significantly lower prevalence of obstructive CAD compared with never users (age-adjusted odds ratio, 0.41 [0.28-0.60]). Women with natural menopause initiating HT before age 55 years had lower CAD severity compared with never users (age-adjusted β [SE] = -6.23 [1.50], P < 0.0001), whereas those initiating HT at age 55 years or more did not differ statistically from never users (-3.34 [2.13], P = 0.12). HT use remained a significant predictor of obstructive CAD when adjusted for a "healthy user" model (odds ratio, 0.44 [0.30-0.73]; P = 0.002). An association between HT and fewer CVD events was observed only in the natural menopause group (hazard ratio [95% CI], 0.60 [0.41-0.88]; P = 0.009) but became nonsignificant when adjusted for the presence or severity of obstructive CAD. Using the quantitative measurements of the timing and type of menopause and HT use, earlier initiation of HT was associated with less angiographic CAD in women with natural but not surgical menopause. Our data suggest that the effect of HT use on reduced cardiovascular event rates is mediated by the presence or absence of angiographic obstructive atherosclerosis.

  6. Unanswered questions for management of acute coronary syndrome: risk stratification of patients with minimal disease or normal findings on coronary angiography.

    PubMed

    Bugiardini, Raffaele; Manfrini, Olivia; De Ferrari, Gaetano M

    2006-07-10

    The prognostic implication of chest pain associated with normal or near-normal findings on angiography is still unknown. We explored outcomes and methods of risk stratification in patients with nonobstructive coronary artery disease in the setting of non-ST-segment elevation acute coronary syndromes. Data were pooled from 3 Thrombolysis in Myocardial Infarction (TIMI) trials (TIMI 11B, TIMI 16, and TIMI 22). Angiographic data were available on 7656 patients with non-ST-segment elevation acute coronary syndromes. The primary end point of this analysis was the composite of the rates of death, myocardial infarction, unstable angina requiring rehospitalization, revascularization, and stroke at 1-year follow-up. Outcomes were evaluated by mean of the TIMI risk score for developing at least 1 component of the primary end point. Angiographic findings showed that 710 (9.1%) of 7656 patients had nonobstructive coronary artery disease; 48.7% of these had normal coronary arteries (0% stenosis), and 51.3% had mild coronary artery disease (>0% to <50% stenosis). A primary end-point event occurred in 101 patients (12.1%). It is noteworthy that a 2% event rate of deaths and myocardial infarctions had occurred in these patients at the 1-year follow-up. Event rates of death and myocardial infarction increased significantly as the TIMI risk score increased from 0.6% for a score of 1 to 4.0% for a score greater than 4. Patients with non-ST-segment elevation acute coronary syndromes with nonobstructive coronary artery disease detected by angiography have a substantial risk of subsequent coronary events within 1 year. The risk is not univariately high, and the TIMI risk score helps to reveal patients at high risk.

  7. The association of ABO blood groups with extent of coronary atherosclerosis in Croatian patients suffering from chronic coronary artery disease.

    PubMed

    Karabuva, Svjetlana; Carević, Vedran; Radić, Mislav; Fabijanić, Damir

    2013-01-01

    The aim of study was to: 1) examine the relationship between ABO blood groups and extent of coronary atherosclerosis in patients with chronic coronary artery disease (CAD), 2) compare ABO blood groups distribution in CAD patients and general population, 3) examine possible differences in traditional risk factors frequency in CAD patients with different ABO blood groups. In the 646 chronic CAD patients (72.4% males) coronary angiograms were scored by quantitative assessment using multiple angiographic scoring system, Traditional risk factors were self reported or measured by standard methods. ABO blood distribution of patients was compared with group of 651 healthy blood donors (74.6% males). Among all ABO blood group patients there was no significant difference between the extent of coronary atherosclerosis with regard to all the three scoring systems: number of affected coronary arteries (P = 0.857), Gensini score (P = 0.818), and number of segments narrowed > 50% (P = 0.781). There was no significant difference in ABO blood group distribution between CAD patients and healthy blood donors. Among CAD patients, men with blood group AB were significantly younger than their pairs with non-AB blood groups (P = 0.008). Among CAD patients with AB blood group, males < 50 yrs were significantly overrepresented when compared with the non-AB groups (P = 0.003). No association between ABO blood groups and the extent of coronary atherosclerosis in Croatian CAD patients is observed. Observation that AB blood group might possibly identify Croatian males at risk to develop the premature CAD has to be tested in larger cohort of patients.

  8. Coronary artery stenosis detection with holographic display of 3D angiograms

    NASA Astrophysics Data System (ADS)

    Ritman, Erik L.; Schwanke, Todd D.; Simari, Robert D.; Schwartz, Robert S.; Thomas, Paul J.

    1995-05-01

    The objective of this study was to establish the accuracy of an holographic display approach for detection of stenoses in coronary arteries. The rationale for using an holographic display approach is that multiple angles of view of the coronary arteriogram are provided by a single 'x-ray'-like film, backlit by a special light box. This should be more convenient in that the viewer does not have to page back and forth through a cine angiogram to obtain the multiple angles of view. The method used to test this technique involved viewing 100 3D coronary angiograms. These images were generated from the 3D angiographic images of nine normal coronary arterial trees generated with the Dynamic Spatial Reconstructor (DSR) fast CT scanner. Using our image processing programs, the image of the coronary artery lumen was locally 'narrowed' by an amount and length and at a location determined by a random look-up table. Two independent, blinded, experienced angiographers viewed the holographic displays of these angiograms and recorded their confidence about the presence, location, and severity of the stenoses. This procedure evaluates the sensitivity and specificity of the detection of coronary artery stenoses as a function of the severity, size, and location along the arteries.

  9. Heart imaging: the accuracy of the 64-MSCT in the detection of coronary artery disease.

    PubMed

    Alessandri, N; Di Matteo, A; Rondoni, G; Petrassi, M; Tufani, F; Ferrari, R; Laghi, A

    2009-01-01

    At present, coronary angiography represents the gold standard technique for the diagnosis of coronary artery disease. Our aim is to compare the conventional coronary angiography to the coronary 64-multislice spiral computed tomography (64-MSCT), a new and non-invasive cardiac imaging technique. The last generation of MSCT scanners show a better imaging quality, due to a greater spatial and temporal resolution. Four expert observers (two cardiologists and two radiologists) have compared the angiographic data with the accuracy of the 64-MSCT in the detection and evaluation of coronary vessels stenoses. From the data obtained, the sensibility, the specificity and the accuracy of the coronary 64-MSCT have been defined. We have enrolled 75 patients (57 male, 18 female, mean age 61.83 +/- 10.38; range 30-80 years) with known or suspected coronary artery disease. The above population has been divided into 3 groups: Group A (Gr. A) with 40 patients (mean age 60.7 +/- 12.5) affected by both non-significant and significant coronary artery disease; Group B (Gr. B) with 25 patients (mean age 60.3 +/- 14.6) who underwent to percutaneous coronary intervention (PCI); Group C (Gr. C) with 10 patients (mean age 54.20 +/- 13.7) without any coronary angiographic stenoses. All the patients underwent non-invasive exams, conventional coronary angiography and coronary 64-MSCT. The comparison of the data obtained has been carried out according to a per group analysis, per patient analysis and per segment analysis. Moreover, the accuracy of the 64-MSCT has been defined for the detection of >75%, 50-75% and <50% coronary stenoses. Coronary angiography has identified significant coronary artery disease in 75% of the patients in the Gr. A and in 73% of the patients in the Gr. B. No coronary stenoses have been detected in Gr. C. According to a per segment analysis, in Gr. A, 36% of the segments analysed have shown a coronary stenosis (37% stenoses >75%, 32% stenoses 50-75% and 31% stenoses <50

  10. Cyanotic congenital heart disease and coronary artery atherogenesis.

    PubMed

    Fyfe, Alistair; Perloff, Joseph K; Niwa, Koichiro; Child, John S; Miner, Pamela D

    2005-07-15

    Hypoxemic erythrocytotic residents of high altitudes lack coronary atherosclerosis and have low cholesterol levels. It was postulated that hypoxemic erythrocytotic adults with cyanotic congenital heart disease (CCHD) might be analogous. The incidence of coronary atherosclerosis in this patient population has not been established, and hypocholesterolemia has not previously been recognized. Accordingly, 279 patients were divided into 4 groups: group A: 143 cyanotic patients not operated on (54 men and 89 women, aged 18 to 69 years); group B: 47 cyanotic patients (28 men and 19 women rendered acyanotic by operation at age 22 to 69 years); group C: 41 acyanotic patients not operated on (22 men and 19 women, aged 22 to 75 years); and group D: 48 patients acyanotic before and after operation (24 men and 24 women, aged 21 to 70 years). Coronary arteries were studied angiographically in 59 patients and at necropsy in 5 subjects aged 37 to 56 years. Total cholesterol was <160 mg/dl in 58% of group A, 52% of group B, 10% of group C, and 12% of group D (p <0.000001, chi-square analysis). Angiograms disclosed dilated coronary arteries without obstruction. Necropsy disclosed ectatic coronary arteries with structural abnormalities of the media. In conclusion, this study provides the first quantitative and qualitative data on antiatherogenic changes in lipoproteins in adults with CCHD. The coronary arteries are atheroma free because hypocholesterolemia acts in concert with the antiatherogenic properties of upregulated nitric oxide, hyperbilirubinemia, hypoxemia, and low platelet counts. The persistence of hypocholesterolemia after the surgical elimination of cyanosis suggests a genetic determinant.

  11. Distal embolization during native vessel and vein graft coronary intervention with a vascular protection device: predictors of high-risk lesions.

    PubMed

    El-Jack, Seif S; Suwatchai, Pornratanarangsi; Stewart, James T; Ruygrok, Peter N; Ormiston, John A; West, Teena; Webster, Mark W I

    2007-12-01

    We sought to define clinical and angiographic variables that may predict patients and lesions at increased risk for distal embolism during percutaneous intervention (PCI), as assessed by debris retrieval from a distal-protection filter device. Distal thrombo- and atheroembolism may contribute to periprocedural myocardial necrosis during PCI, which may in turn affect long-term outcomes. Distal protection devices have been used to reduce this occurrence with variable outcomes depending on lesion and patient subsets. 194 consecutive patients in whom the FilterWire(R) device (FW) [Boston Scientific Corp., Natick, MA] was used for native coronary vessel (n =129) or vein graft (n = 65) PCI were studied. FW debris was visually analyzed using a semi-quantitative grading score. Patients with "significant" debris (particles > or = 1 mm diameter) were compared with those with "nonsignificant" debris (no debris or particles <1 mm) with respect to clinical (age, gender, coronary disease risk factors, clinical presentation, periprocedural medications), and angiographic (vessel treated, vessel size, lesion length, lesion characteristics, angiographic thrombus and TIMI flow before and after PCI) variables. Significant debris was retrieved in 55% of patients, more frequently from vein graft (69%) than native vessel lesions (48%, p = 0.006). No clinical characteristics predicted significant debris retrieval. Angiographic predictors of significant debris by multivariate analysis were longer stent length and final TIMI flow <3 (p = 0.009 and 0.007, respectively). Longer stent length, likely reflecting increased lesion length and plaque burden, predicted significant distal embolism during PCI in native vessel and vein graft lesions, as assessed by debris collected in a distal vascular protection device. This suggests that use of vascular protection devices should be considered during PCI of long lesions.

  12. Comparing Coronary Atheroma Progression Rates and Coronary Events in the United States, Canada, Latin America, and Europe.

    PubMed

    Puri, Rishi; Nicholls, Stephen J; St John, Julie; Tuzcu, E Murat; Kapadia, Samir R; Uno, Kiyoko; Kataoka, Yu; Wolski, Kathy; Nissen, Steven E

    2016-12-01

    We explored for geographic variations in coronary atheroma progression rates in the United States compared to other world regions (Canada, Latin America, Western Europe, and Central-Eastern Europe) and sought to ascertain if this associated with regional differences in major adverse cardiovascular events (MACE; cardiovascular death, nonfatal myocardial infarction, coronary revascularization). Across 7 randomized trials with a global recruitment pattern, 5,451 participants with angiographic coronary disease underwent serial coronary intravascular ultrasonography during 18 or 24 months, with adjudicated MACE. Change in coronary percent atheroma volume (ΔPAV) and MACE in the United States versus other world regions were assessed. Despite similar baseline angiographic and plaque characteristics across participants and regions, following propensity-weighted and multivariate analysis, US (n = 3,706) versus non-US (n = 1,745) participants demonstrated marginal but significantly greater annualized ΔPAV (least-square means ± SE: 0.27 ± 0.14% vs 0.062 ± 0.14%, p = 0.005). However, MACE rates were disproportionately higher in US compared to non-US participants (23.5% vs 10.9%, p <0.001), driven by a doubling in crude rates of coronary revascularization procedures (16.1% vs 7.8%, p <0.001). The US participants hospitalized with unstable angina demonstrated more significant disease progression than their non-US counterparts (ΔPAV: 0.57 ± 0.19% vs -0.30 ± 0.36%, p = 0.033) and greater MACE (9.1% vs 4.8%, p <0.001). A US geographic disposition independently associated with MACE (hazard ratio 1.53, 95% confidence interval 1.22 to 1.92, p <0.001). In conclusion, in participants with stable coronary disease, coronary atheroma progression rates are modestly higher in US-based compared to non-US-based participants. Elective coronary revascularization rates however are disproportionately greater in US-based participants. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Spontaneous coronary artery dissection—A review

    PubMed Central

    Yip, Amelia

    2015-01-01

    Spontaneous coronary artery dissection (SCAD) is an infrequent and often missed diagnosis among patients presenting with acute coronary syndrome (ACS). Unfortunately, SCAD can result in significant morbidities such as myocardial ischemia and infarction, ventricular arrhythmias and sudden cardiac death. Lack of angiographic recognition from clinicians is a major factor of under-diagnosis. With the advent of new imaging modalities, particularly with intracoronary imaging, there has been improved diagnosis of SCAD. The aim of this paper is to review the epidemiology, etiology, presentation, diagnosis and management of SCAD. PMID:25774346

  14. Minimally invasive direct coronary artery bypass grafting: a meta-analysis.

    PubMed

    Kettering, K

    2008-12-01

    Recently minimally invasive direct coronary artery bypass (MIDCAB) grafting has become an interesting alternative to conventional coronary artery bypass grafting, especially in patients with a high-grade left anterior descending coronary artery (LAD) stenosis unsuitable for balloon angioplasty. Although MIDCAB offers several advantages such as the avoidance of sternotomy and cardiopulmonary bypass, concerns have been raised about the technical accuracy of the anastomoses that can be performed on a beating heart. Therefore, clinical and angiographic outcomes after MIDCAB are the subject of current controversy. A literature search for all published outcome studies of MIDCAB grafting was performed for the period from January 1995 through October 2007. Seventeen articles were enrolled in this meta-analysis. The data presented in the studies was analyzed with regard to clinical and angiographic results. Early and late (>30 days after MIDCAB) death rates were 1.3% (51/4081 patients) and 3.2% (130/4081 patients), respectively. The infarct rate was 0.8% (32/4081 patients; non-fatal myocardial infarction). Other minor or major complications (e.g. reoperation for management of bleeding, chest wound problems, arrhythmias, cerebrovascular accident, pericardial effusion, pulmonary complications) were reported in 781 cases. The conversion rate to sternotomy/cardiopulmonary bypass was 1.8% (74/4081 patients). A re-intervention due to graft failure was necessary in 134/4081 patients (3.3%). A total of 2556 grafts were studied angiographically immediately after surgery. One hundred and six grafts (4.2%) were occluded and 169 grafts (6.6 %) had a significant stenosis (50-99%). At 6-month follow-up, 445 grafts were studied angiographically. Sixteen grafts (3.6%) were occluded and 32 grafts (7.2%) had a significant stenosis. Clinical outcomes and immediate graft patency after MIDCAB are acceptable. However, long-term follow-up results and further randomized prospective clinical trials

  15. [Immediate and Long-term Results of the First in Russia of IntrocoronaryMetal Stent in the Coronary Artery].

    PubMed

    Babunashvili, A M; Navtsishvili, Z G; Konstantinov, B A

    2016-02-01

    The authors present immediate and long term results of the first in Russia implantation in coronary artery of Palmaz-Shatz metal stent. Indications for stenting were urgent after complicated dissection as a result of balloon dilation of discrete bifurcational stenosis of anterior interventricular artery (IVA). Immediate angiographic and clinical result was good. At control angiography after 13 years their was no restenosis in stented IVA. However novel narrowing was found in left main coronary artery (LMCA) in which drug eluting stent was implanted. Coronary angiography carried out after 7.5 years after stenting of LMCA and in 20 years after stent implantation in IVA revealed good patency of both stented segments without signs of restenosis. This case report demonstrates possibility of long term preservation of angiographic and clinical effect of staged endovascular treatment of coronary atherosclerosis.

  16. [Implantation of the paclitaxel-eluting stent Apollo in patients with stable angina pectoris: long-term angiographic and clinical results].

    PubMed

    Batyraliev, T A; Fettser, D V; Samko, A N; Sidorenko, B A

    2010-01-01

    to assess the long-term angiographic and clinical results of percutaneous coronary interventions (PCI) with implantation of the drug-eluting stent (DES) Apollo in patients with stable angina pectoris. The study enrolled 48 patients with stable angina who had been implanted with 59 stents. A follow-up of the patients lasted 12 months. The intervention was successful in 100% patients. Following 12 months, 81.3% of the patients underwent angiography that demonstrated that the vascular diameter decreased by 0.32 +/- 0.45 mm and the rate of restenosis was reduced by only 5.3%. The frequency of evident cardiac complications over 12 months was as high as 11.6%. The DES Apollo provides a way of safely performing PCI, by achieving a high of angiographic success rate. The application of this stent yields long-term good angiographic and clinical results in patients with stable angina pectoris.

  17. Culprit Vessel-Only vs. Staged Multivessel Percutaneous Coronary Intervention Strategies in Patients With Multivessel Coronary Artery Disease Undergoing Primary Percutaneous Coronary Intervention for ST-Segment Elevation Myocardial Infarction.

    PubMed

    Toyota, Toshiaki; Shiomi, Hiroki; Taniguchi, Tomohiko; Morimoto, Takeshi; Furukawa, Yutaka; Nakagawa, Yoshihisa; Horie, Minoru; Kimura, Takeshi

    2016-01-01

    We assessed the current status of treatment strategy in ST-segment elevation myocardial infarction (STEMI) with multivessel disease (MVD) in real world practice, focusing on the benefit of staged percutaneous coronary intervention (PCI). From the CREDO-Kyoto AMI Registry, 2,010 STEMI patients with MVD undergoing primary PCI were analyzed. Only 96 patients (4.8%) received acute multivessel PCI, and the majority of patients (n=1,914, 95.2%) had culprit-only PCI acutely. After excluding 699 patients (acute multivessel PCI, Killip class ≥3, age ≥90 years, coronary artery bypass grafting within 90 days, or clinical events within 90 days), 681 MVD patients underwent staged PCI for angiographically significant non-culprit lesions within 90 days (staged PCI group), while 630 MVD patients received primary PCI only (culprit-only PCI group). The cumulative 5-year incidence of and adjusted risk for all-cause death were significantly lower in the staged PCI group compared with the culprit-only PCI group (9.5% vs. 16.0%, P<0.001; HR, 0.69; 95% CI: 0.50-0.96, P=0.03). The risks for MI and any coronary revascularization favored the staged PCI strategy. The staged PCI strategy for angiographically significant non-culprit lesions was associated with lower 5-year mortality compared with the culprit-only PCI strategy in STEMI patients with MVD who underwent primary PCI.

  18. Stenting and surgery for coronary vasospasm : the wrong solution fails to solve the problem.

    PubMed

    Nedeljkovic, Milan A; Ostojic, Miodrag; Lalic, Nebojsa; Beleslin, Branko; Nedeljkovic, Ivana; Lalic, Katarina; Ristic, Miljko; Giga, Vojislav; Angelkov, Lazar; Tomasevic, Miloje; Kanjuh, Vladimir

    2009-11-01

    A 55-year-old man, with a history of medically uncontrolled coronary vasospasm, presented for evaluation of chest pain 6 months after implantation of left internal mammary artery. Due to recurrent episodes of vasospastic angina and serious complications of coronary spasm (ventricular fibrillation, myocardial infarction), a stent had previously been implanted in the proximal part of left anterior descending artery at the site of angiographically and ergonovine-proven coronary spasm, with subsequent in-stent restenosis.

  19. The Effect of Cilostazol on the Angiographic Outcome of Drug-Eluting Coronary Stents Angiographic Analysis of the CILON-T (Influence of CILostazol-Based Triple Antiplatelet Therapy ON Ischemi Complication after Drug-Eluting StenT Implantation) Trial.

    PubMed

    Suh, Jung-Won; Lee, Seung-Pyo; Park, KyungWoo; Kang, Hyun-Jae; Koo, Bon-Kwon; Cho, Young-Seok; Youn, Tae-Jin; Chae, In-Ho; Choi, Dong-Ju; Rha, Seung-Woon; Bae, Jang-Ho; Kwon, Taek-Geun; Bae, Jang-Whan; Cho, Myeong-Chan; Kim, Hyo-Soo

    2017-12-12

    It is not clear if anti-restonotic effect of cilostazol is consistent for different types of drug-eluting stents (DES).The purpose of this study was to compare the anti-proliferative effect of cilostazol between DAT and TAT with consideration of confounding influences of DES type.Nine hundred and fifteen patients were randomized to either dual antiplatelet therapy (DAT; aspirin and clopidogrel) or triple antiplatelet therapy (TAT; aspirin, clopidogrel, and cilostazol) in the previous CILON-T trial. After excluding 70 patients who received both or neither stents, we analyzed 845 patients who received exclusively PES or ZES, and compared in-stent late loss at 6 months between both antiplatelet regimens (DAT versus TAT).Baseline angiographic and clinical characteristics were similar between the DAT (656 lesions in 425 patients) and the TAT group (600 lesions in 420 patients). The 6-month follow-up angiography was completed in 745 patients (88.2%). Quantitative coronary angiography showed that TAT significantly reduced in-stent late loss (DAT 0.62 ± 0.62 mm versus TAT 0.54 ± 0.49 mm, P = 0.015). Stent type, diabetes or lesion length did not interact with difference of late loss. However, reduction of late loss by cilostazol did not lead to a significant reduction in the rate of target lesion revascularization (TLR) (DAT 7.8% versus TAT 6.9%, P = 0.69) due to a nonlinear relationship found between late loss and TLR.The TAT group showed less in-stent late loss as compared to the DAT group. This was consistently observed regardless of DES type, lesion length, or diabetic status. However, reduction of late loss by cilostazol did not lead to a significant reduction in TLR.

  20. Experimental Evaluation of a New Tubular Coronary Stent (V-Flexª).

    PubMed

    Shun; Wang; Zhou; Verbeken; Ping; Szilard; Yanming; Jianhua; De Scheerder IK

    1998-11-01

    The safety, efficacy, angiographic and histological effects of a new 316 L, SS seamless stainless steel tubular stent (V-Flexª, Global Therapeutics, Broomfield, Colorado) was evaluated in a porcine coronary and peripheral artery model. Implantation in the right coronary artery was successful in all 16 pigs. Eight pigs were angiographically controlled after 6 weeks and then sacrificed for morphometric analysis. All stented coronary vessels were widely patent at this moment and morphometric analysis showed only a mild fibromuscular neointimal hyperplasia resulting in a neointimal hyperplasia of 1.15 +/- 0.38 mm2. The remaining 8 pigs were controlled and sacrificed at 12 weeks. At that time, all stented vessels were patent and neointimal hyperplasia was 1.22 +/- 0.34 mm2. Comparison with the Palmaz-Schatzª coronary stent (Cordis, Miami, Florida) in a porcine peripheral artery model demonstrated significantly less neointimal hyperplasia at 6 weeks (1.11 +/- 0.73 vs. 2.40 +/- 0.36, p = 0.001) and at 12 weeks (1.53 +/- 0.42 vs. 2.47 +/- 0.63, p = 0.003) for the V-Flex stent. In conclusion, V-Flex coronary stent implantation in a porcine coronary and peripheral arteries results in a high procedural success rate without subacute thrombotic occlusions, despite no further anticoagulation nor antiplatelet therapy. Six and 12 week histopathological and morphometric evaluation demonstrated only a mild fibromuscular neointimal hyperplasia. Comparison with the Palmaz-Schatz coronary stent in a peripheral artery model showed significantly less neointimal hyperplasia in the V-Flex stent.

  1. A new methodology for accurate 3-dimensional coronary artery reconstruction using routine intravascular ultrasound and angiographic data: implications for widespread assessment of endothelial shear stress in humans.

    PubMed

    Bourantas, Christos V; Papafaklis, Michail I; Athanasiou, Lambros; Kalatzis, Fanis G; Naka, Katerina K; Siogkas, Panagiotis K; Takahashi, Saeko; Saito, Shigeru; Fotiadis, Dimitrios I; Feldman, Charles L; Stone, Peter H; Michalis, Lampros K

    2013-09-01

    To develop and validate a new methodology that allows accurate 3-dimensional (3-D) coronary artery reconstruction using standard, simple angiographic and intravascular ultrasound (IVUS) data acquired during routine catheterisation enabling reliable assessment of the endothelial shear stress (ESS) distribution. Twenty-two patients (22 arteries: 7 LAD; 7 LCx; 8 RCA) who underwent angiography and IVUS examination were included. The acquired data were used for 3-D reconstruction using a conventional method and a new methodology that utilised the luminal 3-D centreline to place the detected IVUS borders and anatomical landmarks to estimate their orientation. The local ESS distribution was assessed by computational fluid dynamics. In corresponding consecutive 3 mm segments, lumen, plaque and ESS measurements in the 3-D models derived by the centreline approach were highly correlated to those derived from the conventional method (r>0.98 for all). The centreline methodology had a 99.5% diagnostic accuracy for identifying segments exposed to low ESS and provided similar estimations to the conventional method for the association between the change in plaque burden and ESS (centreline method: slope= -1.65%/Pa, p=0.078; conventional method: slope= -1.64%/Pa, p=0.084; p =0.69 for difference between the two methodologies). The centreline methodology provides geometrically correct models and permits reliable ESS computation. The ability to utilise data acquired during routine coronary angiography and IVUS examination will facilitate clinical investigation of the role of local ESS patterns in the natural history of coronary atherosclerosis.

  2. Virtual Resting Pd/Pa From Coronary Angiography and Blood Flow Modelling: Diagnostic Performance Against Fractional Flow Reserve.

    PubMed

    Papafaklis, Michail I; Muramatsu, Takashi; Ishibashi, Yuki; Bourantas, Christos V; Fotiadis, Dimitrios I; Brilakis, Emmanouil S; Garcia-Garcia, Héctor M; Escaned, Javier; Serruys, Patrick W; Michalis, Lampros K

    2018-03-01

    Fractional flow reserve (FFR) has been established as a useful diagnostic tool. The distal coronary pressure to aortic pressure (Pd/Pa) ratio at rest is a simpler physiologic index but also requires the use of the pressure wire, whereas recently proposed virtual functional indices derived from coronary imaging require complex blood flow modelling and/or are time-consuming. Our aim was to test the diagnostic performance of virtual resting Pd/Pa using routine angiographic images and a simple flow model. Three-dimensional quantitative coronary angiography (3D-QCA) was performed in 139 vessels (120 patients) with intermediate lesions assessed by FFR. The resting Pd/Pa for each lesion was assessed by computational fluid dynamics. The discriminatory power of virtual resting Pd/Pa against FFR (reference: ≤0.80) was high (area under the receiver operator characteristic curve [AUC]: 90.5% [95% CI: 85.4-95.6%]). Diagnostic accuracy, sensitivity and specificity for the optimal virtual resting Pd/Pa cut-off (≤0.94) were 84.9%, 90.4% and 81.6%, respectively. Virtual resting Pd/Pa demonstrated superior performance (p<0.001) versus 3D-QCA %area stenosis (AUC: 77.5% [95% CI: 69.8-85.3%]). There was a good correlation between virtual resting Pd/Pa and FFR (r=0.69, p<0.001). Virtual resting Pd/Pa using routine angiographic data and a simple flow model provides fast functional assessment of coronary lesions without requiring the pressure-wire and hyperaemia induction. The high diagnostic performance of virtual resting Pd/Pa for predicting FFR shows promise for using this simple/fast virtual index in clinical practice. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  3. Quantification of myocardium at risk in ST- elevation myocardial infarction: a comparison of contrast-enhanced steady-state free precession cine cardiovascular magnetic resonance with coronary angiographic jeopardy scores.

    PubMed

    De Palma, Rodney; Sörensson, Peder; Verouhis, Dinos; Pernow, John; Saleh, Nawzad

    2017-07-27

    Clinical outcome following acute myocardial infarction is predicted by final infarct size evaluated in relation to left ventricular myocardium at risk (MaR). Contrast-enhanced steady-state free precession (CE-SSFP) cardiovascular magnetic resonance imaging (CMR) is not widely used for assessing MaR. Evidence of its utility compared to traditional assessment methods and as a surrogate for clinical outcome is needed. Retrospective analysis within a study evaluating post-conditioning during ST elevation myocardial infarction (STEMI) treated with coronary intervention (n = 78). CE-SSFP post-infarction was compared with angiographic jeopardy methods. Differences and variability between CMR and angiographic methods using Bland-Altman analyses were evaluated. Clinical outcomes were compared to MaR and extent of infarction. MaR showed correlation between CE-SSFP, and both BARI and APPROACH scores of 0.83 (p < 0.0001) and 0.84 (p < 0.0001) respectively. Bias between CE-SSFP and BARI was 1.1% (agreement limits -11.4 to +9.1). Bias between CE-SSFP and APPROACH was 1.2% (agreement limits -13 to +10.5). Inter-observer variability for the BARI score was 0.56 ± 2.9; 0.42 ± 2.1 for the APPROACH score; -1.4 ± 3.1% for CE-SSFP. Intra-observer variability was 0.15 ± 1.85 for the BARI score; for the APPROACH score 0.19 ± 1.6; and for CE-SSFP -0.58 ± 2.9%. Quantification of MaR with CE-SSFP imaging following STEMI shows high correlation and low bias compared with angiographic scoring and supports its use as a reliable and practical method to determine myocardial salvage in this patient population. Clinical trial registration information for the parent clinical trial: Karolinska Clinical Trial Registration (2008) Unique identifier: CT20080014. Registered 04 th January 2008.

  4. High plasma omentin predicts cardiovascular events independently from the presence and extent of angiographically determined atherosclerosis.

    PubMed

    Saely, Christoph H; Leiherer, Andreas; Muendlein, Axel; Vonbank, Alexander; Rein, Philipp; Geiger, Kathrin; Malin, Cornelia; Drexel, Heinz

    2016-01-01

    No prospective data on the power of the adipocytokine omentin to predict cardiovascular events are available. We aimed at investigating i) the association of plasma omentin with cardiometabolic risk markers, ii) its association with angiographically determined coronary atherosclerosis, and iii) its power to predict cardiovascular events. We measured plasma omentin in 295 patients undergoing coronary angiography for the evaluation of established or suspected stable coronary artery disease (CAD), of whom 161 had significant CAD with coronary artery stenoses ≥50% and 134 did not have significant CAD. Over 3.5 years, 17.6% of our patients suffered cardiovascular events, corresponding to an annual event rate of 5.0%. At baseline, plasma omentin was not significantly associated with metabolic syndrome stigmata and did not differ significantly between patients with and subjects without significant CAD (17.2 ± 13.6 ng/ml vs. 17.5 ± 15.1 ng/ml; p = 0.783). Prospectively, however, cardiovascular event risk significantly increased over tertiles of omentin (12.1%, 13.8%, and 29.5%, for tertiles 1 through 3; ptrend = 0.003), and omentin as a continuous variable significantly predicted cardiovascular events after adjustment for age, gender, BMI, diabetes, hypertension, LDL cholesterol, HDL cholesterol, and smoking (standardized adjusted hazard ratio (HR) 1.41 [95% CI 1.16-1.72]; p < 0.001), as well as after additional adjustment for the presence and extent of significant CAD at baseline (HR 1.59 [95% CI 1.29-1.97, p < 0.001). From this first prospective evaluation of the cardiovascular risk associated with omentin we conclude that elevated plasma omentin significantly predicts cardiovascular events independently from the presence and extent of angiographically determined baseline CAD. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  5. Late Diagnosed Left Coronary to the Pulmonary Artery Large Fistulae: An Interesting and Incidental Cath Lab Finding

    PubMed Central

    de Melo, Pedro H. M. Craveiro; Abreu-Silva, Érlon O.; Coura, Fernando Barbiero; Rios, Gleyson Moraes; Potério, Daniel Izzet

    2016-01-01

    Coronary artery anomalies are congenital changes in their origin, course, and/or structure. Most of them are discovered as incidental findings during coronary angiographic studies or at autopsies. A coronary artery fistulae involve a communication between a coronary artery and a chamber of the heart or any segment of the systemic or pulmonary circulation. We present herein the case of a 67-year-old man with a recent history of exertional angina and dyspnea to usual daily activities whose coronary angiogram revealed an interesting and incidental coronary-pulmonary artery large fistulae. PMID:28053791

  6. Late Diagnosed Left Coronary to the Pulmonary Artery Large Fistulae: An Interesting and Incidental Cath Lab Finding.

    PubMed

    Oliveira, Marcos Danillo P; de Melo, Pedro H M Craveiro; Abreu-Silva, Érlon O; Coura, Fernando Barbiero; Rios, Gleyson Moraes; Potério, Daniel Izzet

    2016-01-01

    Coronary artery anomalies are congenital changes in their origin, course, and/or structure. Most of them are discovered as incidental findings during coronary angiographic studies or at autopsies. A coronary artery fistulae involve a communication between a coronary artery and a chamber of the heart or any segment of the systemic or pulmonary circulation. We present herein the case of a 67-year-old man with a recent history of exertional angina and dyspnea to usual daily activities whose coronary angiogram revealed an interesting and incidental coronary-pulmonary artery large fistulae.

  7. Does grafting coronary arteries with only moderate stenosis affect long-term mortality?

    PubMed Central

    Sabik, Joseph F.; Olivares, Gabriel; Raza, Sajjad; Lytle, Bruce W.; Houghtaling, Penny L.; Blackstone, Eugene H.

    2016-01-01

    Objective Stenting coronary arteries with non–ischemia-producing moderate stenosis leads to worse outcomes than leaving them unstented. We sought to determine whether grafting coronary arteries with angiographically moderate stenosis is associated with worse long-term survival than leaving them ungrafted. Methods From 1972 to 2011, 55,567 patients underwent primary isolated coronary artery bypass grafting (CABG); 8531 had a single coronary artery with moderate (50%-69%) stenosis, bypassed in 6598 (77%) and not bypassed in 1933 (23%). These arteries were grafted with internal thoracic arteries (ITAs) in 1806 patients (27%) and with saphenous veins (SVs) in 4625 (70%). Mean follow-up for all-cause mortality was 13.0 ± 9.7 years. Results Survival was similar for patients with and without a graft to the moderately stenosed coronary artery (P = .3): 97%, 76%, 43%, and 18% at 1, 10, 20, and 30 years among patients receiving no graft; 97%, 74%, 41%, and 18% among those receiving an SV graft; and 98%, 82%, 51%, and 23% among those receiving an ITA graft. After adjusting for patient characteristics, SV grafting versus nongrafting of moderately stenosed coronary arteries was associated with similar long-term mortality (P = .2), whereas ITA grafting was associated with 22% lower long-term mortality (hazard ratio 0.78; 68% confidence interval 0.75–0.82; P<.0001). Conclusions Grafting coronary arteries with angiographically moderate stenosis is not harmful. Instead, ITA grafting of such coronary arteries is associated with lower long-term mortality. Thus, after placing the first ITA to the left anterior descending, the second ITA should be placed to the second most important coronary artery, even if it is moderately stenosed. PMID:26611750

  8. Does grafting coronary arteries with only moderate stenosis affect long-term mortality?

    PubMed

    Sabik, Joseph F; Olivares, Gabriel; Raza, Sajjad; Lytle, Bruce W; Houghtaling, Penny L; Blackstone, Eugene H

    2016-03-01

    Stenting coronary arteries with non-ischemia-producing moderate stenosis leads to worse outcomes than leaving them unstented. We sought to determine whether grafting coronary arteries with angiographically moderate stenosis is associated with worse long-term survival than leaving them ungrafted. From 1972 to 2011, 55,567 patients underwent primary isolated coronary artery bypass grafting (CABG); 8531 had a single coronary artery with moderate (50%-69%) stenosis, bypassed in 6598 (77%) and not bypassed in 1933 (23%). These arteries were grafted with internal thoracic arteries (ITAs) in 1806 patients (27%) and with saphenous veins (SVs) in 4625 (70%). Mean follow-up for all-cause mortality was 13.0 ± 9.7 years. Survival was similar for patients with and without a graft to the moderately stenosed coronary artery (P = .3): 97%, 76%, 43%, and 18% at 1, 10, 20, and 30 years among patients receiving no graft; 97%, 74%, 41%, and 18% among those receiving an SV graft; and 98%, 82%, 51%, and 23% among those receiving an ITA graft. After adjusting for patient characteristics, SV grafting versus nongrafting of moderately stenosed coronary arteries was associated with similar long-term mortality (P = .2), whereas ITA grafting was associated with 22% lower long-term mortality (hazard ratio 0.78; 68% confidence interval 0.75-0.82; P < .0001). Grafting coronary arteries with angiographically moderate stenosis is not harmful. Instead, ITA grafting of such coronary arteries is associated with lower long-term mortality. Thus, after placing the first ITA to the left anterior descending, the second ITA should be placed to the second most important coronary artery, even if it is moderately stenosed. Copyright © 2016. Published by Elsevier Inc.

  9. Asymptomatic subjects with zero coronary calcium score: coronary CT angiographic features of plaques in event-prone patients.

    PubMed

    Lee, Min Su; Chun, Eun Ju; Kim, Kil Joong; Kim, Jeong A; Yoo, Jin Young; Choi, Sang Il

    2013-06-01

    The aims of this study were: (a) to assess clinical predictors and coronary computed tomography angiography (CCTA) characteristics of noncalcified coronary plaques (NCP) in subjects who had cardiac events despite a zero coronary artery calcium score (CACS), and (b) to describe computed tomography (CT) plaque characteristics in subjects with cardiac events. A total of 7,961 subjects with zero CACS were evaluated; 6,531 subjects underwent CCTA as part of a health check-up. Those who had zero CACS were included in our mid-term follow-up study. Cardiac events included cardiac death, acute coronary syndrome or revascularization with stable angina. More than one NCP was identified in 441 subjects with zero CACS, including 48 subjects with obstructive coronary artery disease (CAD) caused by NCPs. Age, male gender, hypertension, diabetes and low density lipoprotein were independent predictors of obstructive CAD. Among subjects with obstructive CAD, young adults were classified into low (79.2 %) or moderate (72.9 %) risk groups by the National Centers for Environmental Prediction III guidelines. Approximately 0.2 % of subjects had cardiac events during our follow-up period. All patients with cardiac events had NCPs with significantly lower mean CT numbers, higher remodeling indexes and worse degree of stenosis. In asymptomatic subjects with zero CACS, NCP was associated with cardiac events. CCTA might be useful for risk stratification among select populations with CAD and zero CACS who have certain plaque characteristics associated with cardiac events.

  10. Influence of Microcirculatory Dysfunction on Angiography-Based Functional Assessment of Coronary Stenoses.

    PubMed

    Mejía-Rentería, Hernán; Lee, Joo Myung; Lauri, Francesco; van der Hoeven, Nina W; de Waard, Guus A; Macaya, Fernando; Pérez-Vizcayno, María José; Gonzalo, Nieves; Jiménez-Quevedo, Pilar; Nombela-Franco, Luis; Salinas, Pablo; Núñez-Gil, Iván; Del Trigo, María; Goto, Sonoka; Lee, Hyun Jong; Liontou, Catherine; Fernández-Ortiz, Antonio; Macaya, Carlos; van Royen, Niels; Koo, Bon-Kwon; Escaned, Javier

    2018-04-23

    The authors sought to evaluate the influence of coronary microcirculatory dysfunction (CMD) on the diagnostic performance of the quantitative flow ratio (QFR). Functional angiographic assessment of coronary stenoses based on fluid dynamics, such as QFR, constitutes an attractive alternative to fractional flow reserve (FFR). However, it is unknown whether CMD affects the reliability of angiography-based functional indices. FFR and the index of microcirculatory resistance (IMR) were measured in 300 vessels (248 patients) as part of a multicenter international registry. QFR was calculated at a blinded core laboratory. Vessels were classified into 2 groups according to microcirculatory status: low IMR (<23 U), and high IMR (≥23 U, CMD). The impact of CMD on the diagnostic performance of QFR, as well as on incremental value of QFR over quantitative angiography, was assessed using FFR as reference. Percent diameter stenosis (%DS) and FFR were similar in low- and high-IMR groups (%DS 51 ± 12% vs. 53 ± 11%; p = 0.16; FFR 0.80 ± 0.11 vs. 0.81 ± 0.11; p = 0.23, respectively). In the overall cohort, classification agreement (CA) between QFR and FFR and diagnostic efficiency of QFR (area under the receiver-operating characteristics curve [AUC]) were high (CA: 88%; AUC: 0.93 [95% confidence interval (CI): 0.90 to 0.96]). However, when assessed according to microcirculatory status, a significantly lower CA and AUC of QFR were found in the high-IMR group as compared with the low-IMR group (CA: 76% vs. 92%; p < 0.001; AUC: 0.88 [95% CI: 0.79 to 0.94] vs. 0.96 [95% CI: 0.92 to 0.98]; p < 0.05). Compared with angiographic assessment, QFR increased by 0.20 (p < 0.001) and by 0.16 (p < 0.001) the AUC of %DS in low- and high-IMR groups, respectively. Independent predictors of misclassification between QFR and FFR were high IMR and acute coronary syndrome. CMD decreases the diagnostic performance of QFR. However, even in the presence of CMD, QFR remains superior to

  11. Severe coronary artery disease after radiation therapy of the chest and mediastinum: clinical presentation and treatment.

    PubMed Central

    Orzan, F; Brusca, A; Conte, M R; Presbitero, P; Figliomeni, M C

    1993-01-01

    OBJECTIVE--To define the clinical and angiographic features and the therapeutic problems in patients with coronary artery disease after therapeutic irradiation of the chest. DESIGN--An observational retrospective study. SETTING--The cardiac catheterisation laboratory, university medical school. PATIENTS--15 subjects (8 men and 7 women, aged 25-56 years, mean 44) examined in the cardiac catheterisation laboratory, who had significant coronary artery disease years after having radiation treatment to the chest and anterior mediastinum. In the early stages of the study angiography was performed because of typical symptoms of ischaemic heart disease. Later on it was performed because of a high index of suspicion in people with signs of extensive radiation heart damage. MAIN OUTCOME MEASURES--Clinical and electrocardiographic evidence of ischaemic heart disease; echocardiographic signs of pericardial, myocardial or valvar involvement; angiographic evidence of coronary arterial stenosis, with special attention to the ostia; haemodynamic and angiographic signs of pericardial, myocardial, and valvar disease. Survival and symptomatic and functional status were ascertained after medical or surgical treatment. RESULTS--The patients were relatively young and had no risk factors. Seven patients had no signs or symptoms of ischaemic heart disease. Ten patients had ostial stenosis, which was associated with extensive involvement of other cardiac structures in nine of them. Seven required surgical treatment for coronary artery disease. Two died, one at surgery and the other one six months later. Five patients had complications associated with irradiation. CONCLUSIONS--Coronary arterial disease can be reasonably ascribed to the effects of chest irradiation when the patients are young and free from risk factors, especially if the obstructions are ostial and there is important damage to other cardiac structures. In patients with damage to other cardiac structures angina and infarction

  12. A prospective randomised trial comparing the novel ridaforolimus-eluting BioNIR stent to the zotarolimus-eluting Resolute stent: six-month angiographic and one-year clinical results of the NIREUS trial.

    PubMed

    Paradies, Valeria; Ben-Yehuda, Ori; Jonas, Michael; Banai, Shmuel; Iñiguez, Andres; Perlman, Gidon Y; Kandzari, David E; Stone, Gregg W; Smits, Pieter C

    2018-05-20

    The aim of this study was to evaluate the efficacy and safety of the BioNIR stent compared with the Resolute Integrity stent for the treatment of coronary artery disease. This first-in-human, multicentre, single-blind randomised non-inferiority trial was performed in Europe and Israel. Patients with stable coronary artery disease or acute coronary syndromes were randomly assigned to treatment with BioNIR or Resolute Integrity stents in a 2:1 fashion. The primary endpoint was angiographic in-stent late lumen loss (LLL) at six months. Three hundred and two patients were randomised, of whom 261 (86.0%) underwent six-month angiographic follow-up. The BioNIR stent was non-inferior to the Resolute Integrity stent for the primary endpoint of in-stent LLL at six months (0.04±0.30 mm vs. 0.03±0.31 mm, respectively, pnoninferiority<0.0001). At 12-month follow-up, target lesion failure occurred in 3.4% in the BioNIR group and 5.9% in the Resolute Integrity group (p=0.22). Rates of MACE were similar between the BioNIR and Resolute Integrity groups (4.3% vs. 5.9%, respectively, p=0.45). The BioNIR stent was non-inferior to the Resolute Integrity stent for the primary endpoint of angiographic in-stent LLL at six months. Clinical outcomes at one year were comparable between the two groups.

  13. Restenosis of the coronary stenotic lesions treated by holmium:YAG laser coronary angioplasty

    NASA Astrophysics Data System (ADS)

    Miyazaki, Shunichi; Nonogi, Hiroshi; Goto, Yoichi; Itoh, Akira; Ozono, Keizaburo; Daikoku, Satoshi; Haze, Kazuo

    1994-07-01

    Clinical efficacy of newly developed Holmium YAG laser coronary angioplasty (HLCA) was assessed for 30 patients with angina. There were 12 near left main trunk (LMT) lesions and 4 aorto- ostial lesions. Adjunctive balloon angioplasty was performed for 25 of 30 lesions. Delivered energy ranged from 1.5 to 2.5 watts/pulse and the total exposure time ranged from 6 to 55 seconds. External diameter of laser catheter was 1.5 mm for 13 lesions, 1.4 mm for 17 lesions, and 1.7 mm for 5 lesions. Laser success, defined as 20% reduction of stenotic ratio, was obtained in 21 of 30 (70%) and overall procedural success rate was 93%. There were 3 cases with acute coronary occlusions relieved by adjunctive balloon angioplasty and one coronary perforation without manifestation of cardiac tamponade. There were no large coronary dissection which involved more than 5 mm of the coronary artery. Follow up coronary angiography after 3 months showed restenosis in 14 of 27 patients (52%). Percent stenosis after lasering (56%) was similar to that at 3 months after (62%). HLCA is acutely effective treatment for lesions near LMT, because of low incidence of large coronary dissection. However, angiographical restenosis rate is high at 3 months after HLCA. This may be attributed to the relatively large residual stenosis after the procedure and vessel injury caused by shock wave.

  14. Sex Differences in Mortality Following Acute Coronary Syndromes

    PubMed Central

    Berger, Jeffrey S.; Elliott, Laine; Gallup, Dianne; Roe, Matthew; Granger, Christopher B.; Armstrong, Paul W.; Simes, R. John; White, Harvey D.; Van de Werf, Frans; Topol, Eric J.; Hochman, Judith S.; Newby, L. Kristin; Harrington, Robert A.; Califf, Robert M; Becker, Richard C.; Douglas, Pamela S.

    2009-01-01

    Context There is conflicting information about whether sex-differences modulate short-term mortality following acute coronary syndromes (ACS). Objective To investigate the relationship between sex and 30-day mortality in ACS, and determine whether this relationship is modified by clinical syndrome or coronary anatomy using a large database across the spectrum of ACS and adjusting for potentially confounding clinical covariates. Design Setting and Participants Data from 11 ACS trials from 1993 to 2006 were pooled. Of 136,247 patients, 38,048 (28%) were women; 102,004 (26% women) STEMI, 14,466 (29% women) NSTEMI and 19,777 (40% women) unstable angina (UA). Main Outcome Measure Thirty-day mortality following ACS. Results Mortality at 30 days was 9.6% in women and 5.3% in men (odds ratio [OR] 1.91, 95% confidence interval [CI] 1.83–2.00). After multivariable adjustment, mortality was not significantly different between women and men (adjusted OR 1.06, 95% CI 0.99–1.15). Importantly, a significant sex by type of ACS interaction was demonstrated (P<0.001). In STEMI, 30-day mortality was higher among women (adjusted OR 1.15, 95% CI 1.06–1.24), whereas NSTEMI (adjusted OR 0.77, 95% CI 0.63–0.95), and UA mortality was lower among women (adjusted OR 0.55, 95% CI 0.43–0.70). In a cohort of 35,128 patients with angiographic data, women more often had non-obstructive (15% vs. 8%,) and less often had 2-vessel (25% vs. 28%) and 3-vessel (23% vs. 26%) coronary disease regardless of ACS type. After additional adjustment for angiographic disease severity, 30-day mortality among women was not significantly different than men, regardless of ACS type. The relationship between sex and 30-day mortality was similar across the levels of angiographic disease severity (p-value for interaction =0.70), Conclusions Sex-based differences exist in 30-day mortality among ACS patients and vary depending on clinical presentation. However, these differences are markedly attenuated following

  15. Sex differences in mortality following acute coronary syndromes.

    PubMed

    Berger, Jeffrey S; Elliott, Laine; Gallup, Dianne; Roe, Matthew; Granger, Christopher B; Armstrong, Paul W; Simes, R John; White, Harvey D; Van de Werf, Frans; Topol, Eric J; Hochman, Judith S; Newby, L Kristin; Harrington, Robert A; Califf, Robert M; Becker, Richard C; Douglas, Pamela S

    2009-08-26

    Conflicting information exists about whether sex differences modulate short-term mortality following acute coronary syndromes (ACS). To investigate the relationship between sex and 30-day mortality in ACS, and to determine whether this relationship was modified by clinical syndrome or coronary anatomy using a large database across the spectrum of ACS and adjusting for potentially confounding clinical covariates. A convenience sample of patients pooled from 11 independent, international, randomized ACS clinical trials between 1993 and 2006 whose databases are maintained at the Duke Clinical Research Institute, Durham, North Carolina. Of 136 247 patients, 38 048 (28%) were women; 102 004 (26% women) with ST-segment elevation myocardial infarction (STEMI), 14 466 (29% women) with non-STEMI (NSTEMI), and 19 777 (40% women) with unstable angina. Thirty-day mortality following ACS. Thirty-day mortality was 9.6% in women and 5.3% in men (odds ratio [OR], 1.91; 95% confidence interval [CI], 1.83-2.00). After multivariable adjustment, mortality was not significantly different between women and men (adjusted OR, 1.06; 95% CI, 0.99-1.15). A significant sex by type of ACS interaction was demonstrated (P < .001). In STEMI, 30-day mortality was higher among women (adjusted OR, 1.15; 95% CI, 1.06-1.24), whereas in NSTEMI (adjusted OR, 0.77; 95% CI, 0.63-0.95) and unstable angina, mortality was lower among women (adjusted OR, 0.55; 95% CI, 0.43-0.70). In a cohort of 35 128 patients with angiographic data, women more often had nonobstructive (15% vs 8%) and less often had 2-vessel (25% vs 28%) and 3-vessel (23% vs 26%) coronary disease, regardless of ACS type. After additional adjustment for angiographic disease severity, 30-day mortality among women was not significantly different than men, regardless of ACS type. The relationship between sex and 30-day mortality was similar across the levels of angiographic disease severity (P for interaction = .70). Sex-based differences existed

  16. Coronary heart disease in the diabetic African: frequency clinical and angiographic features.

    PubMed

    Touze, J E; Ekra, A; Darracq, R; Mardelle, T; Adoh, A; Ake, E; Chauvet, J; Bertrand, E

    1987-01-01

    The frequency and clinical and coronarographic features of coronary heart disease (CHD) in black African diabetic patients were assessed in a two-part study. The aim of part I was to determine the frequency of CHD in 50 diabetic patients selected by the following criteria: male, age between 40 and 60 years, diabetes history less than 20 years, no history of CHD and normal E.K.G. All 50 of these patients underwent a stress test and those who failed or for whom results were inconclusive were submitted to coronary arteriography. Part II was a retrospective study of 104 patients with CHD. Its aim was to compare the clinical and coronarographic features of CHD patients with (27 cases) and without (77 cases) diabetes mellitus. The frequency of CHD in the 50 diabetics selected for this study was 10% (31 negative exercise tests, 19 inconclusive exercise tests, 5 coronary arteriographies with significant narrowing). Of these 5 diabetics with CHD, 3 had single vessel involvement (left descending artery: 2 cases, circumflex artery: 1 case), 1 patient had double vessel involvement (right coronary circumflex artery) and 1 had triple vessel involvement (left descending, circumflex, and right coronary artery). In the retrospective study the clinical profile of the diabetic and non-diabetic CHD patients was the same with respect to sex, age, angina, myocardial infarction, and death rate. As regard the risk factors, blood cholesterol level was higher in diabetics while cigarette smoking was higher in non-diabetics. The frequency of hypertension was the same in both groups.(ABSTRACT TRUNCATED AT 250 WORDS)

  17. Atherosclerosis and Liver Function Tests in Coronary Angiography Patients.

    PubMed

    Doganer, Y C; Rohrer, J E; Aydogan, U; Agerter, D C; Cayci, T; Barcin, C

    2015-09-01

    Elevated aminotransferase levels indicating liver function, even in the normal range, have attracted great concern as potential novel markers of cardiovascular risk assessment. We hypothesized the possibility that liver function test variations in the normal range might be meaningfully associated to coronary artery disease (CAD). Eighty-eight patients were randomly selected from those who underwent coronary angiography from June 2010 to June 2011 after applying to the outpatient cardiology clinic in Gulhane Military Medical Academy. According to the results of angiographies, patients were classified into three groups as normal, non-critical (< 50% involvement in coronaries), and critical (≥ 50% involvement in coronaries). In addition to angiographic intervention, measurements of serum aspartate aminotransferase (AST) and alanine aminotransferase (ALT) concentrations, albumin and the other serum parameters were performed in all patients. The patient groups of CAD were balanced (28 critical cases, 30 non-critical cases and 30 normal cases). Mean age was 51.93 ± 9.3 (range 32-65) years and 19.3 per cent (n = 17) were females. Multiple linear regression analysis of all three liver function tests explained a significant portion of the variance, but adjusted r-squares were small (AST = 0.174, ALT = 0.242, albumin = 0.124). Albumin was significantly higher for patients with critical CAD than for patients with no CAD (beta = 3.205, p = 0.002). Non-critical CAD was not significantly different from no CAD for any of the dependent variables. Mean AST was significantly higher for patients taking aspirin (beta = 0.218, p = 0.049), as was mean ALT (beta = 0.264, p = 0.015). Alanine aminotransferase and AST may not be associated with angiographically determined coronary atherosclerosis. Albumin may be more sensitive to demonstrate the burden of atherosclerosis. These results indicate that the association between the liver function tests and coronary atherosclerosis may be more

  18. Spontaneous coronary artery dissection: association with predisposing arteriopathies and precipitating stressors and cardiovascular outcomes.

    PubMed

    Saw, Jacqueline; Aymong, Eve; Sedlak, Tara; Buller, Christopher E; Starovoytov, Andrew; Ricci, Donald; Robinson, Simon; Vuurmans, Tycho; Gao, Min; Humphries, Karin; Mancini, G B John

    2014-10-01

    Nonatherosclerotic spontaneous coronary artery dissection (NA-SCAD) is underdiagnosed and an important cause of myocardial infarction in young women. The frequency of predisposing and precipitating conditions and cardiovascular outcomes remains poorly described. Patients with NA-SCAD prospectively evaluated (retrospectively or prospectively identified) at Vancouver General Hospital were included. Angiographic SCAD diagnosis was confirmed by 2 experienced interventional cardiologists and categorized as type 1 (multiple lumen), 2 (diffuse stenosis), or 3 (mimic atherosclerosis). Fibromuscular dysplasia screening of renal, iliac, and cerebrovascular arteries were performed with angiography or computed tomographic angiography/MR angiography. Baseline, predisposing and precipitating conditions, angiographic, revascularization, in-hospital, and long-term events were recorded. We prospectively evaluated 168 patients with NA-SCAD. Average age was 52.1±9.2 years, 92.3% were women (62.3% postmenopausal). All presented with myocardial infarction. ECG showed ST-segment elevation in 26.1%, and 3.6% had ventricular tachycardia/ventricular fibrillation arrest. Fibromuscular dysplasia was diagnosed in 72.0%. Precipitating emotional or physical stress was reported in 56.5%. Majority had type 2 angiographic SCAD (67.0%), only 29.1% had type 1, and 3.9% had type 3. The majority (134/168) were initially treated conservatively. Overall, 6 of 168 patients had coronary artery bypass surgery and 33 of 168 had percutaneous coronary intervention in-hospital. Of those treated conservatively (n=134), 3 required revascularization for SCAD extension, and all 79 who had repeat angiogram ≥26 days later had spontaneous healing. Two-year major adverse cardiac events were 16.9% (retrospectively identified group) and 10.4% (prospectively identified group). Recurrent SCAD occurred in 13.1%. Majority of patients with NA-SCAD had fibromuscular dysplasia and type 2 angiographic SCAD. Conservative

  19. Randomized Comparison of Ridaforolimus- and Zotarolimus-Eluting Coronary Stents in Patients With Coronary Artery Disease: Primary Results From the BIONICS Trial (BioNIR Ridaforolimus-Eluting Coronary Stent System in Coronary Stenosis).

    PubMed

    Kandzari, David E; Smits, Pieter C; Love, Michael P; Ben-Yehuda, Ori; Banai, Shmuel; Robinson, Simon D; Jonas, Michael; Kornowski, Ran; Bagur, Rodrigo; Iniguez, Andres; Danenberg, Haim; Feldman, Robert; Jauhar, Rajiv; Chandna, Harish; Parikh, Manish; Perlman, Gidon Y; Balcells, Mercedes; Markham, Peter; Ozan, Melek Ozgu; Genereux, Philippe; Edelman, Elazer R; Leon, Martin B; Stone, Gregg W

    2017-10-03

    The safety and efficacy of a novel cobalt alloy-based coronary stent with a durable elastomeric polymer eluting the antiproliferative agent ridaforolimus for treatment of patients with coronary artery disease is undetermined. A prospective, international 1:1 randomized trial was conducted to evaluate in a noninferiority design the relative safety and efficacy of ridaforolimus-eluting stents (RESs) and slow-release zotarolimus-eluting stents among 1919 patients undergoing percutaneous coronary intervention at 76 centers. Inclusion criteria allowed enrollment of patients with recent myocardial infarction, total occlusions, bifurcations lesions, and other complex conditions. Baseline clinical and angiographic characteristics were similar between the groups. Overall, mean age was 63.4 years, 32.5% had diabetes mellitus, and 39.7% presented with acute coronary syndromes. At 12 months, the primary end point of target lesion failure (composite of cardiac death, target vessel-related myocardial infarction, and target lesion revascularization) was 5.4% for both devices (upper bound of 1-sided 95% confidence interval 1.8%, P noninferiority =0.001). Definite/probable stent thrombosis rates were low in both groups (0.4% RES versus 0.6% zotarolimus-eluting stent, P =0.75); 13-month angiographic in-stent late lumen loss was 0.22±0.41 mm and 0.23±0.39 mm ( P noninferiority =0.004) for the RES and zotarolimus-eluting stent groups, respectively, and intravascular ultrasound percent neointimal hyperplasia was 8.10±5.81 and 8.85±7.77, respectively ( P noninferiority =0.01). In the present trial, which allowed broad inclusion criteria, the novel RESs met the prespecified criteria for noninferiority compared with zotarolimus-eluting stents for the primary end point of target lesion failure at 12 months and had similar measures of late lumen loss. These findings support the safety and efficacy of RESs in patients who are representative of clinical practice. URL: http

  20. Effectiveness of atrial fibrillation as an independent predictor of death and coronary events in patients having coronary angiography.

    PubMed

    Marte, Thomas; Saely, Christoph H; Schmid, Fabian; Koch, Lorena; Drexel, Heinz

    2009-01-01

    The impact of atrial fibrillation (AF) on future coronary events is uncertain. In particular, the prognostic impact of AF in the clinically important population of coronary patients who undergo angiography is unknown. The aim of this study was to investigate (1) the prevalence of AF, (2) its association with coronary atherosclerosis, and (3) its impact on future coronary events in patients who undergo angiography. Electrocardiograms were evaluated in a consecutive series of 613 patients who underwent coronary angiography. Prospectively, death and cardiovascular events were recorded over 4.0 +/- 0.6 years. Among these patients, 37 (6%) at baseline had AF, and 576 (94%) were in sinus rhythm. The presence of AF was associated with a lower prevalence of coronary artery disease and of coronary diameter narrowing >or=50% on baseline angiography. However, prospectively, patients with AF were at a strongly increased risk for all-cause mortality (adjusted hazard ratio 5.15, 95% confidence interval 2.36 to 11.26, p <0.001), coronary death (hazard ratio 8.16, 95% confidence interval 2.89 to 23.09, p <0.001), and major coronary events (hazard ratio 3.80, 95% confidence interval 1.45 to 9.94, p = 0.007). In conclusion, although inversely associated with the presence of angiographically determined coronary atherosclerosis, AF is a strong predictor of death and future coronary events in patients with coronary artery disease who undergo coronary angiography.

  1. Relationship between platelet-to-lymphocyte ratio and coronary slow flow.

    PubMed

    Oylumlu, Muhammed; Doğan, Adnan; Oylumlu, Mustafa; Yıldız, Abdülkadir; Yüksel, Murat; Kayan, Fethullah; Kilit, Celal; Amasyalı, Basri

    2015-05-01

    The coronary slow flow phenomenon (CSFP), which is characterized by delayed distal vessel opacification in the absence of significant epicardial coronary disease, is an angiographic finding. The aim of this study is to investigate the association between platelet-to-lymphocyte ratio (PLR) and coronary blood flow rate. This is a retrospective observational study. It was based on two medical centers. A total of 197 patients undergoing coronary angiography were included in the study, 95 of whom were patients with coronary slow flow without stenosis in coronary angiography and 102 of whom had normal coronary arteries and normal flow. The PLR was higher in the coronary slow flow group compared with the control groups (p=0.001). In the correlation analysis, PLR showed a significant correlation with left anterior descending (LAD) artery thrombolysis in myocardial infarction (TIMI) frame count. After multiple logistic regression, high levels of PLR were independently associated with coronary slow flow, together with hemoglobin. PLR was higher in patients with CSFP, and we also showed that PLR was significantly and independently associated with CSFP.

  2. Very high-pressure dilatation for undilatable coronary lesions: indications and results with a new dedicated balloon.

    PubMed

    Secco, Gioel Gabrio; Ghione, Matteo; Mattesini, Alessio; Dall'Ara, Gianni; Ghilencea, Liviu; Kilickesmez, Kadriye; De Luca, Giuseppe; Fattori, Rossella; Parisi, Rosario; Marino, Paolo Nicola; Lupi, Alessandro; Foin, Nicolas; Di Mario, Carlo

    2016-06-20

    Calcific coronary lesions impose a rigid obstacle to optimal balloon and stent expansion and the 20 to 30 atm limit that non-compliant (NC) balloons reach can be insufficient. The aim of our study was to evaluate the safety and efficacy of a new dedicated super high-pressure NC balloon (OPN NC®; SIS Medical AG, Winterthur, Switzerland). We retrospectively evaluated a consecutive series of 91 lesions in which conventional NC balloons at maximal pressure failed to achieve an adequate post-dilatation luminal gain and were therefore treated with an OPN NC balloon up to 40 atm. Angiographic success was defined as residual angiographic diameter stenosis <30%. MLD and %DS were measured at baseline, after NC balloon, OPN NC balloon and stent implantation. Angiographic success was achieved in 84 lesions (92.3%). All of the remaining lesions received rotational atherectomy with the exception of two cases in which rotational atherectomy was not attempted because of small vessel size and excessive tortuosity. MLD and acute gain were significantly greater and %DS was significantly lower post OPN NC balloon compared with conventional NC balloon inflation (p<0.001). No coronary perforations occurred. No acute or 30-day follow-up MACE was reported. When conventional NC balloons fail, the new OPN NC dedicated high-pressure balloon provides an effective and safe alternative strategy for the dilatation of resistant coronary lesions.

  3. Evaluation of coronary stenosis with the aid of quantitative image analysis in histological cross sections.

    PubMed

    Dulohery, Kate; Papavdi, Asteria; Michalodimitrakis, Manolis; Kranioti, Elena F

    2012-11-01

    Coronary artery atherosclerosis is a hugely prevalent condition in the Western World and is often encountered during autopsy. Atherosclerotic plaques can cause luminal stenosis: which, if over a significant level (75%), is said to contribute to cause of death. Estimation of stenosis can be macroscopically performed by the forensic pathologists at the time of autopsy or by microscopic examination. This study compares macroscopic estimation with quantitative microscopic image analysis with a particular focus on the assessment of significant stenosis (>75%). A total of 131 individuals were analysed. The sample consists of an atherosclerotic group (n=122) and a control group (n=9). The results of the two methods were significantly different from each other (p=0.001) and the macroscopic method gave a greater percentage stenosis by an average of 3.5%. Also, histological examination of coronary artery stenosis yielded a difference in significant stenosis in 11.5% of cases. The differences were attributed to either histological quantitative image analysis underestimation; gross examination overestimation; or, a combination of both. The underestimation may have come from tissue shrinkage during tissue processing for histological specimen. The overestimation from the macroscopic assessment can be attributed to the lumen shape, to the examiner observer error or to a possible bias to diagnose coronary disease when no other cause of death is apparent. The results indicate that the macroscopic estimation is open to more biases and that histological quantitative image analysis only gives a precise assessment of stenosis ex vivo. Once tissue shrinkage, if any, is accounted for then histological quantitative image analysis will yield a more accurate assessment of in vivo stenosis. It may then be considered a complementary tool for the examination of coronary stenosis. Copyright © 2012 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  4. Effectiveness of Myocardial Contrast Echocardiography Quantitative Analysis during Adenosine Stress versus Visual Analysis before Percutaneous Therapy in Acute Coronary Pain: A Coronary Artery TIMI Grading Comparing Study

    PubMed Central

    Yang, Lixia; Mu, Yuming; Quaglia, Luiz Augusto; Tang, Qi; Guan, Lina; Wang, Chunmei; Shih, Ming Chi

    2012-01-01

    The study aim was to compare two different stress echocardiography interpretation techniques based on the correlation with thrombosis in myocardial infarction (TIMI ) flow grading from acute coronary syndrome (ACS) patients. Forty-one patients with suspected ACS were studied before diagnostic coronary angiography with myocardial contrast echocardiography (MCE) at rest and at stress. The correlation of visual interpretation of MCE and TIMI flow grade was significant. The quantitative analysis (myocardial perfusion parameters: A, β, and A × β) and TIMI flow grade were significant. MCE visual interpretation and TIMI flow grade had a high degree of agreement, on diagnosing myocardial perfusion abnormality. If one considers TIMI flow grade <3 as abnormal, MCE visual interpretation at rest had 73.1% accuracy with 58.2% sensitivity and 84.2% specificity and at stress had 80.4% accuracy with 76.6% sensitivity and 83.3% specificity. The MCE quantitative analysis has better accuracy with 100% of agreement with different level of TIMI flow grading. MCE quantitative analysis at stress has showed a direct correlation with TIMI flow grade, more significant than the visual interpretation technique. Further studies could measure the clinical relevance of this more objective approach to managing acute coronary syndrome patient before percutaneous coronary intervention (PCI). PMID:22778555

  5. Prognostic and Practical Validation of Current Definitions of Myocardial Infarction Associated With Percutaneous Coronary Intervention.

    PubMed

    Tricoci, Pierluigi; Newby, L Kristin; Clare, Robert M; Leonardi, Sergio; Gibson, C Michael; Giugliano, Robert P; Armstrong, Paul W; Van de Werf, Frans; Montalescot, Gilles; Moliterno, David J; Held, Claes; Aylward, Philip E; Wallentin, Lars; Harrington, Robert A; Braunwald, Eugene; Mahaffey, Kenneth W; White, Harvey D

    2018-05-14

    In 13,038 patients with non-ST-segment elevation acute coronary syndrome undergoing index percutaneous coronary intervention (PCI) in the EARLY ACS (Early Glycoprotein IIb/IIIa Inhibition in Non-ST-Segment Elevation Acute Coronary Syndrome) and TRACER (Thrombin Receptor Antagonist for Clinical Event Reduction in Acute Coronary Syndrome) trials, the relationship between PCI-related myocardial infarction (MI) and 1-year mortality was assessed. The definition of PCI-related MI is controversial. The third universal definition of PCI-related MI requires cardiac troponin >5 times the 99th percentile of the normal reference limit from a stable or falling baseline and PCI-related clinical or angiographic complications. The definition from the Society for Cardiovascular Angiography and Interventions (SCAI) requires creatine kinase-MB elevation >10 times the upper limit of normal (or 5 times if new electrocardiographic Q waves are present). Implications of these definitions on prognosis, prevalence, and implementation are not established. In our cohort of patients undergoing PCI, PCI-related MIs were classified using the third universal type 4a MI definition and SCAI criteria. In the subgroup of patients included in the angiographic core laboratory (ACL) substudy of EARLY ACS (n = 1,401) local investigator- versus ACL-reported angiographic complications were compared. Altogether, 2.0% of patients met third universal definition of PCI-related MI criteria, and 1.2% met SCAI criteria. One-year mortality was 3.3% with the third universal definition (hazard ratio: 1.96; 95% confidence interval: 1.24 to 3.10) and 5.3% with SCAI criteria (hazard ratio: 2.79; 95% confidence interval: 1.69 to 4.58; p < 0.001). Agreement between ACL and local investigators in detecting angiographic complications during PCI was overall moderate (κ = 0.53). The third universal definition of MI and the SCAI definition were both associated with significant risk for mortality at 1 year. Suboptimal

  6. Quantitative assessment on coronary computed tomography angiography (CCTA) image quality: comparisons between genders and different tube voltage settings.

    PubMed

    Chian, Teo Chee; Nassir, Norziana Mat; Ibrahim, Mohd Izuan; Yusof, Ahmad Khairuddin Md; Sabarudin, Akmal

    2017-02-01

    This study was carried out to quantify and compare the quantitative image quality of coronary computed tomography angiography (CCTA) between genders as well as between different tube voltages scan protocols. Fifty-five cases of CCTA were collected retrospectively and all images including reformatted axial images at systolic and diastolic phases as well as images with curved multi planar reformation (cMPR) were obtained. Quantitative image quality including signal intensity, image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of right coronary artery (RCA), left anterior descending artery (LAD), left circumflex artery (LCx) and left main artery (LM) were quantified using Analyze 12.0 software. Six hundred and fifty-seven coronary arteries were evaluated. There were no significant differences in any quantitative image quality parameters between genders. 100 kilovoltage peak (kVp) scanning protocol produced images with significantly higher signal intensity compared to 120 kVp scanning protocol (P<0.001) in all coronary arteries in all types of images. Higher SNR was also observed in 100 kVp scan protocol in all coronary arteries except in LCx where 120 kVp showed better SNR than 100 kVp. There were no significant differences in image quality of CCTA between genders and different tube voltages. Lower tube voltage (100 kVp) scanning protocol is recommended in clinical practice to reduce the radiation dose to patient.

  7. Quantitative micro-CT based coronary artery profiling using interactive local thresholding and cylindrical coordinates.

    PubMed

    Panetta, Daniele; Pelosi, Gualtiero; Viglione, Federica; Kusmic, Claudia; Terreni, Marianna; Belcari, Nicola; Guerra, Alberto Del; Athanasiou, Lambros; Exarchos, Themistoklis; Fotiadis, Dimitrios I; Filipovic, Nenad; Trivella, Maria Giovanna; Salvadori, Piero A; Parodi, Oberdan

    2015-01-01

    Micro-CT is an established imaging technique for high-resolution non-destructive assessment of vascular samples, which is gaining growing interest for investigations of atherosclerotic arteries both in humans and in animal models. However, there is still a lack in the definition of micro-CT image metrics suitable for comprehensive evaluation and quantification of features of interest in the field of experimental atherosclerosis (ATS). A novel approach to micro-CT image processing for profiling of coronary ATS is described, providing comprehensive visualization and quantification of contrast agent-free 3D high-resolution reconstruction of full-length artery walls. Accelerated coronary ATS has been induced by high fat cholesterol-enriched diet in swine and left coronary artery (LCA) harvested en bloc for micro-CT scanning and histologic processing. A cylindrical coordinate system has been defined on the image space after curved multiplanar reformation of the coronary vessel for the comprehensive visualization of the main vessel features such as wall thickening and calcium content. A novel semi-automatic segmentation procedure based on 2D histograms has been implemented and the quantitative results validated by histology. The potentiality of attenuation-based micro-CT at low kV to reliably separate arterial wall layers from adjacent tissue as well as identify wall and plaque contours and major tissue components has been validated by histology. Morphometric indexes from histological data corresponding to several micro-CT slices have been derived (double observer evaluation at different coronary ATS stages) and highly significant correlations (R2 > 0.90) evidenced. Semi-automatic morphometry has been validated by double observer manual morphometry of micro-CT slices and highly significant correlations were found (R2 > 0.92). The micro-CT methodology described represents a handy and reliable tool for quantitative high resolution and contrast agent free full length

  8. Randomized Comparison of Ridaforolimusand Zotarolimus-Eluting Coronary Stents in Patients With Coronary Artery Disease

    PubMed Central

    Kandzari, David E.; Smits, Pieter C.; Love, Michael P.; Ben-Yehuda, Ori; Banai, Shmuel; Rob-inson, Simon D.; Jonas, Michael; Kornowski, Ran; Bagur, Rodrigo; Iniguez, Andres; Danenberg, Haim; Feldman, Robert; Jauhar, Rajiv; Chandna, Harish; Parikh, Manish; Perlman, Gidon Y.; Balcells, Mer-cedes; Markham, Peter; Ozan, Melek Ozgu; Genereux, Philippe; Edelman, Elazer R.; Leon, Martin B.; Stone, Gregg W.

    2018-01-01

    BACKGROUND The safety and efficacy of a novel cobalt alloy-based coronary stent with a durable elastomeric polymer eluting the antiproliferative agent ridaforolimus for treatment of patients with coronary artery disease is undetermined. METHODS A prospective, international 1:1 randomized trial was conducted to evaluate in a noninferiority design the relative safety and efficacy of ridaforolimus-eluting stents (RESs) and slow-release zotarolimus-eluting stents among 1919 patients undergoing percutaneous coronary intervention at 76 centers. Inclusion criteria allowed enrollment of patients with recent myocardial infarction, total occlusions, bifurcations lesions, and other complex conditions. RESULTS Baseline clinical and angiographic characteristics were similar between the groups. Overall, mean age was 63.4 years, 32.5% had diabetes mellitus, and 39.7% presented with acute coronary syndromes. At 12 months, the primary end point of target lesion failure (composite of cardiac death, target vessel-related myocardial infarction, and target lesion revascularization) was 5.4% for both devices (upper bound of 1-sided 95% confidence interval 1.8%, Pnoninferiority=0.001). Definite/probable stent thrombosis rates were low in both groups (0.4% RES versus 0.6% zotarolimus-eluting stent, P=0.75); 13-month angiographic in-stent late lumen loss was 0.22±0.41 mm and 0.23±0.39 mm (Pnoninferiority=0.004) for the RES and zotarolimus-eluting stent groups, respectively, and intravascular ultrasound percent neointimal hyperplasia was 8.10±5.81 and 8.85±7.77, respectively (Pnoninferiority=0.01). CONCLUSIONS In the present trial, which allowed broad inclusion criteria, the novel RESs met the prespecified criteria for noninferiority compared with zotarolimus-eluting stents for the primary end point of target lesion failure at 12 months and had similar measures of late lumen loss. These findings support the safety and efficacy of RESs in patients who are representative of clinical

  9. A new method for real-time co-registration of 3D coronary angiography and intravascular ultrasound or optical coherence tomography.

    PubMed

    Carlier, Stéphane; Didday, Rich; Slots, Tristan; Kayaert, Peter; Sonck, Jeroen; El-Mourad, Mike; Preumont, Nicolas; Schoors, Dany; Van Camp, Guy

    2014-06-01

    We present a new clinically practical method for online co-registration of 3D quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS) or optical coherence tomography (OCT). The workflow is based on two modified commercially available software packages. Reconstruction steps are explained and compared to previously available methods. The feasibility for different clinical scenarios is illustrated. The co-registration appears accurate, robust and induced a minimal delay on the normal cath lab activities. This new method is based on the 3D angiographic reconstruction of the catheter path and does not require operator's identification of landmarks to establish the image synchronization. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Quantitative analysis of regional myocardial performance in coronary artery disease

    NASA Technical Reports Server (NTRS)

    Stewart, D. K.; Dodge, H. T.; Frimer, M.

    1975-01-01

    Findings from a group of subjects with significant coronary artery stenosis are given. A group of controls determined by use of a quantitative method for the study of regional myocardial performance based on the frame-by-frame analysis of biplane left ventricular angiograms are presented. Particular emphasis was placed upon the analysis of wall motion in terms of normalized segment dimensions, timing and velocity of contraction. The results were compared with the method of subjective assessment used clinically.

  11. High-speed coronary rotational angioplasty with the rotablator

    NASA Astrophysics Data System (ADS)

    Zacca, Nadim M.; Kleiman, Neal S.; Asimacopoulos, P. J.

    1992-08-01

    Percutaneous mechanical rotational ablation with the rotablator can be used effectively as a stand alone treatment for coronary arterial lesions, including those with angiographic morphology considered unfavorable for balloon angioplasty (eccentric, at bends, bifurcating, calcified, ulcerated, completely occluded_, as well as for balloon angioplasty procedure failures. The use of single rather than multiple burrs without balloon assistance, the use of fewer passes and of the nitroglycerine infusion through the rotablator catheter have considerably shortened the time necessary to complete a rotational atherectomy. Further, the apparently infrequent occurrence of post procedure abrupt closure makes this technique attractive in the clinical management of patients with complex coronary artery lesions.

  12. Quantitative assessment on coronary computed tomography angiography (CCTA) image quality: comparisons between genders and different tube voltage settings

    PubMed Central

    Chian, Teo Chee; Nassir, Norziana Mat; Ibrahim, Mohd Izuan; Yusof, Ahmad Khairuddin Md

    2017-01-01

    Background This study was carried out to quantify and compare the quantitative image quality of coronary computed tomography angiography (CCTA) between genders as well as between different tube voltages scan protocols. Methods Fifty-five cases of CCTA were collected retrospectively and all images including reformatted axial images at systolic and diastolic phases as well as images with curved multi planar reformation (cMPR) were obtained. Quantitative image quality including signal intensity, image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of right coronary artery (RCA), left anterior descending artery (LAD), left circumflex artery (LCx) and left main artery (LM) were quantified using Analyze 12.0 software. Results Six hundred and fifty-seven coronary arteries were evaluated. There were no significant differences in any quantitative image quality parameters between genders. 100 kilovoltage peak (kVp) scanning protocol produced images with significantly higher signal intensity compared to 120 kVp scanning protocol (P<0.001) in all coronary arteries in all types of images. Higher SNR was also observed in 100 kVp scan protocol in all coronary arteries except in LCx where 120 kVp showed better SNR than 100 kVp. Conclusions There were no significant differences in image quality of CCTA between genders and different tube voltages. Lower tube voltage (100 kVp) scanning protocol is recommended in clinical practice to reduce the radiation dose to patient. PMID:28275559

  13. Routine Angiographic Follow-Up versus Clinical Follow-Up after Percutaneous Coronary Intervention in Acute Myocardial Infarction

    PubMed Central

    Kim, Yong Hoon; Her, Ae-Young; Choi, Byoung Geol; Shim, Minsuk; Choi, Se Yeon; Byun, Jae Kyeong; Li, Hu; Kim, Woohyeun; Kang, Jun Hyuk; Choi, Jah Yeon; Park, Eun Jin; Park, Sung Hun; Lee, Sunki; Na, Jin Oh; Choi, Cheol Ung; Lim, Hong Euy; Kim, Eung Ju; Park, Chang Gyu; Seo, Hong Seog; Oh, Dong Joo

    2017-01-01

    Purpose Differences in the utility of routine angiographic follow-up (RAF) and clinical follow-up (CF) after percutaneous coronary intervention (PCI) in acute myocardial infarction (AMI) are not well understood. The present study aimed to compare the 3-year clinical outcomes of RAF and CF in AMI patients who underwent PCI with drug-eluting stents (DES). Materials and Methods A total of 774 consecutive AMI patients who underwent PCI with DES were enrolled. RAF was performed at 6 to 9 months after index PCI (n=425). The remaining patients were medically managed and clinically followed (n=349); symptom-driven events were captured. To adjust for any potential confounders, a propensity score matched analysis was performed using a logistic regression model, and two propensity-matched groups (248 pairs, n=496, C-statistic=0.739) were generated. Cumulative clinical outcomes up to 3 years were compared between RAF and CF groups. Results During the 3-year follow-up period, the cumulative incidences of revascularization [target lesion revascularization: hazard ratio (HR), 2.40; 95% confidence interval (CI), 1.18–4.85; p=0.015, target vessel revascularization (TVR): HR, 3.33; 95% CI, 1.69–6.58; p=0.001, non-TVR: HR, 5.64; 95% CI, 1.90–16.6; p=0.002] and major adverse cardiac events (MACE; HR, 3.32; 95% CI, 1.92–5.73; p<0.001) were significantly higher in the RAF group than the CF group. However, the 3-year incidences of death and myocardial infarction were not different between the two groups. Conclusion RAF following index PCI with DES in AMI patients was associated with increased incidences of revascularization and MACE. Therefore, CF seems warranted for asymptomatic patients after PCI for AMI. PMID:28540983

  14. Long-term clinical and angiographic results of Sirolimus-Eluting Stent in Complex Coronary Chronic Total Occlusion Revascularization: the SECTOR registry.

    PubMed

    Galassi, Alfredo R; Tomasello, Salvatore D; Costanzo, Luca; Campisano, Maria B; Barrano, Giombattista; Tamburino, Corrado

    2011-10-01

    Drug-eluting stents showed a better angiographic and clinical outcome in comparison with bare metal stent in chronic total occlusions (CTOs) percutaneous revascularization, however, great concerns still remain regarding the rate of restenosis and reocclusion in comparison with nonocclusive lesions. To evaluate angiographic and clinical outcomes after sirolimus-eluting stent (SES) implantation in the setting of a "real world" series of complex CTOs. From January 2006 to December 2008, 172 consecutive patients with 179 CTO lesions were enrolled into registry. Among these, successful recanalization was obtained in 144 lesions (80.4%) with exclusive SES implantation in 104 lesions. The 9-12 months angiographic follow-up was executed in 85.5% of lesions with evidence of angiographic binary restenosis in 16.8% of lesions. Total stent length and number of stent implanted were recognized as independent predictors of restenosis (odds ratio [OR] 4.7, 95% confidence interval [CI] 1.28-107.09, P = 0.02) and (OR 5.8, 95% CI 1.39-23.55, P = 0.01), respectively.The 2-year clinical follow-up showed rates of target lesion revascularization, non-Q wave myocardial infarction, and total major adverse cardiovascular events (MACEs) of 11.1%, 2%, and 13.1%, respectively. Cox proportional-hazard analysis showed diabetes as independent predictor of MACEs (hazard ratio [HR] 4.832; 95% CI, 0.730-0.861; P = 0.028). Data from this registry demonstrate the long-term efficacy and safety of SES implantation after complex CTOs recanalization. ©2011, Wiley Periodicals, Inc.

  15. Excess Cardiovascular Risk in Women Relative to Men Referred for Coronary Angiography Is Associated With Severely Impaired Coronary Flow Reserve, Not Obstructive Disease.

    PubMed

    Taqueti, Viviany R; Shaw, Leslee J; Cook, Nancy R; Murthy, Venkatesh L; Shah, Nishant R; Foster, Courtney R; Hainer, Jon; Blankstein, Ron; Dorbala, Sharmila; Di Carli, Marcelo F

    2017-02-07

    Cardiovascular disease (CVD) fatality rates are higher for women than for men, yet obstructive coronary artery disease (CAD) is less prevalent in women. Coronary flow reserve (CFR), an integrated measure of large- and small-vessel CAD and myocardial ischemia, identifies patients at risk for CVD death, but is not routinely measured in clinical practice. We sought to investigate the impact of sex, CFR, and angiographic CAD severity on adverse cardiovascular events. Consecutive patients (n=329, 43% women) referred for invasive coronary angiography after stress testing with myocardial perfusion positron emission tomography and with left ventricular ejection fraction >40% were followed (median, 3.0 years) for a composite end point of major adverse cardiovascular events, including cardiovascular death and hospitalization for nonfatal myocardial infarction or heart failure. The extent and severity of angiographic CAD were estimated by using the CAD prognostic index, and CFR was quantified by using positron emission tomography. Although women in comparison with men had lower pretest clinical scores, rates of prior myocardial infarction, and burden of angiographic CAD (P<0.001), they demonstrated greater risk of CVD events, even after adjustment for traditional risk factors, imaging findings, and early revascularization (adjusted hazard ratio, 2.05; 95% confidence interval, 1.05-4.02; P=0.03). Impaired CFR was similarly present among women and men, but in patients with low CFR (<1.6, n=163), women showed a higher frequency of nonobstructive CAD, whereas men showed a higher frequency of severely obstructive CAD (P=0.002). After also adjusting for CFR, the effect of sex on outcomes was no longer significant. When stratified by sex and CFR, only women with severely impaired CFR demonstrated significantly increased adjusted risk of CVD events (P<0.0001, P for interaction=0.04). Women referred for coronary angiography had a significantly lower burden of obstructive CAD in

  16. Routine Clinical Quantitative Rest Stress Myocardial Perfusion for Managing Coronary Artery Disease: Clinical Relevance of Test-Retest Variability.

    PubMed

    Kitkungvan, Danai; Johnson, Nils P; Roby, Amanda E; Patel, Monika B; Kirkeeide, Richard; Gould, K Lance

    2017-05-01

    Positron emission tomography (PET) quantifies stress myocardial perfusion (in cc/min/g) and coronary flow reserve to guide noninvasively the management of coronary artery disease. This study determined their test-retest precision within minutes and daily biological variability essential for bounding clinical decision-making or risk stratification based on low flow ischemic thresholds or follow-up changes. Randomized trials of fractional flow reserve-guided percutaneous coronary interventions established an objective, quantitative, outcomes-driven standard of physiological stenosis severity. However, pressure-derived fractional flow reserve requires invasive coronary angiogram and was originally validated by comparison to noninvasive PET. The time course and test-retest precision of serial quantitative rest-rest and stress-stress global myocardial perfusion by PET within minutes and days apart in the same patient were compared in 120 volunteers undergoing serial 708 quantitative PET perfusion scans using rubidium 82 (Rb-82) and dipyridamole stress with a 2-dimensional PET-computed tomography scanner (GE DST 16) and University of Texas HeartSee software with our validated perfusion model. Test-retest methodological precision (coefficient of variance) for serial quantitative global myocardial perfusion minutes apart is ±10% (mean ΔSD at rest ±0.09, at stress ±0.23 cc/min/g) and for days apart is ±21% (mean ΔSD at rest ±0.2, at stress ±0.46 cc/min/g) reflecting added biological variability. Global myocardial perfusion at 8 min after 4-min dipyridamole infusion is 10% higher than at standard 4 min after dipyridamole. Test-retest methodological precision of global PET myocardial perfusion by serial rest or stress PET minutes apart is ±10%. Day-to-different-day biological plus methodological variability is ±21%, thereby establishing boundaries of variability on physiological severity to guide or follow coronary artery disease management. Maximum stress

  17. ABSORB II randomized controlled trial: a clinical evaluation to compare the safety, efficacy, and performance of the Absorb everolimus-eluting bioresorbable vascular scaffold system against the XIENCE everolimus-eluting coronary stent system in the treatment of subjects with ischemic heart disease caused by de novo native coronary artery lesions: rationale and study design.

    PubMed

    Diletti, Roberto; Serruys, Patrick W; Farooq, Vasim; Sudhir, Krishnankutty; Dorange, Cecile; Miquel-Hebert, Karine; Veldhof, Susan; Rapoza, Richard; Onuma, Yoshinobu; Garcia-Garcia, Hector M; Chevalier, Bernard

    2012-11-01

    Currently, no data are available on the direct comparison between the Absorb everolimus-eluting bioresorbable vascular scaffold (Absorb BVS) and conventional metallic drug-eluting stents. The ABSORB II study is a randomized, active-controlled, single-blinded, multicenter clinical trial aiming to compare the second-generation Absorb BVS with the XIENCE everolimus-eluting metallic stent. Approximately 501 subjects will be enrolled on a 2:1 randomization basis (Absorb BVS/XIENCE stent) in approximately 40 investigational sites across Europe and New Zealand. Treated lesions will be up to 2 de novo native coronary artery lesions, each located in different major epicardial vessels, all with an angiographic maximal luminal diameter between 2.25 and 3.8 mm as estimated by online quantitative coronary angiography (QCA) and a lesion length of ≤48 mm. Clinical follow-up is planned at 30 and 180 days and at 1, 2, and 3 years. All subjects will undergo coronary angiography, intravascular ultrasound (IVUS) and IVUS-virtual histology at baseline (pre-device and post-device implantation) and at 2-year angiographic follow-up. The primary end point is superiority of the Absorb BVS vs XIENCE stent in terms of vasomotor reactivity of the treated segment at 2 years, defined as the QCA quantified change in the mean lumen diameter prenitrate and postnitrate administration. The coprimary end point is the noninferiority (reflex to superiority) of the QCA-derived minimum lumen diameter at 2 years postnitrate minus minimum lumen diameter postprocedure postnitrate by QCA. In addition, all subjects allocated to the Absorb BVS group will undergo multislice computed tomography imaging at 3 years. The ABSORB II randomized controlled trial (ClinicalTrials.gov NCT01425281) is designed to compare the safety, efficacy, and performance of Absorb BVS against the XIENCE everolimus-eluting stent in the treatment of de novo native coronary artery lesions. Copyright © 2012 Mosby, Inc. All rights

  18. Meta-analysis of randomized trials of percutaneous transluminal coronary angioplasty versus atherectomy, cutting balloon atherotomy, or laser angioplasty.

    PubMed

    Bittl, John A; Chew, Derek P; Topol, Eric J; Kong, David F; Califf, Robert M

    2004-03-17

    We conducted a systematic overview (meta-analysis) of randomized trials of balloon angioplasty versus coronary atherectomy, laser angioplasty, or cutting balloon atherotomy to evaluate the effects of plaque modification during percutaneous coronary intervention. Several mechanical approaches have been developed that ablate or section atheromatous plaque during percutaneous coronary interventions to optimize acute results, minimize intimal injury, and reduce complications and restenosis. Sixteen trials (9,222 patients) constitute the randomized controlled experience with atherectomy, laser, or atherotomy versus balloon angioplasty with or without coronary stenting. Each trial tested the hypothesis that ablative therapy would result in better clinical or angiographic results than balloon dilation alone. Short-term death rates (<31 days) were not improved by the use of ablative procedures (0.3% vs. 0.4%, odds ratio [OR] 0.94 [95% confidence interval 0.46 to 1.92]), but periprocedural myocardial infarctions (4.4% vs. 2.5%, OR 1.83 [95% CI 1.43 to 2.34]) and major adverse cardiac events (5.1% vs. 3.3%, OR 1.54 [95% CI 1.25 to 1.89]) were increased. Angiographic restenosis rates (6,958 patients) were not improved with the ablative devices (38.9% vs. 37.4%, OR 1.06 [95% CI 0.97 to 1.17]). No reduction in revascularization rates (25.2% vs. 24.5%, OR 1.04 [95% CI 0.94 to 1.14]) or cumulative adverse cardiac events rates up to one year after treatment were seen with ablative devices (27.8% vs. 26.1%, OR 1.09 [95% CI 0.99 to 1.20]). The combined experience from randomized trials suggests that ablative devices failed to achieve predefined clinical and angiographic outcomes. This meta-analysis does not support the hypothesis that routine ablation or sectioning of atheromatous tissue is beneficial during percutaneous coronary interventions.

  19. Pravastatin and endothelium dependent vasomotion after coronary angioplasty: the PREFACE trial.

    PubMed

    Mulder, H J; Schalij, M J; Kauer, B; Visser, R F; van Dijkman, P R; Jukema, J W; Zwinderman, A H; Bruschke, A V

    2001-11-01

    To test the hypothesis that the 3-hydroxy-3-methylglutaryl coenzyme-A reductase inhibitor pravastatin ameliorates endothelium mediated responses of dilated coronary segments: the PREFACE (pravastatin related effects following angioplasty on coronary endothelium) trial. A double blind, randomised, placebo controlled, multicentre study. Four hospitals in the Netherlands. 63 non-smoking, non-hypercholesterolaemic patients scheduled for elective balloon angioplasty (pravastatin 34, placebo 29). The effects of three months of pravastatin treatment (40 mg daily) on endothelium dependent vasomotor function were studied. Balloon angioplasty was undertaken one month after randomisation, and coronary vasomotor function tests using acetylcholine were performed two months after balloon angioplasty. The angiograms were analysed quantitatively. The efficacy measure was the acetylcholine induced change in mean arterial diameter, determined in the dilated segment and in an angiographically normal segment of an adjacent non-manipulated coronary artery. Increasing acetylcholine doses produced vasoconstriction in the dilated segments (p = 0.004) but not in the normal segments. Pravastatin did not affect the vascular response to acetylcholine in either the dilated segments (p = 0.09) or the non-dilated sites. Endothelium dependent vasomotion in normal segments was correlated with that in dilated segments (r = 0.47, p < 0.001). There were fewer procedure related events in the pravastatin group than in the placebo group (p < 0.05). Endothelium dependent vasomotion in normal segments is correlated with that in dilated segments. A significant beneficial effect of pravastatin on endothelial function could not be shown, but in the dilated segments there was a trend towards a beneficial treatment effect in the pravastatin group.

  20. Severity of coronary artery disease in obese patients undergoing coronary angiography: "obesity paradox" revisited.

    PubMed

    Niraj, Ashutosh; Pradhan, Jyotiranjan; Pradahan, Jyotiranjan; Fakhry, Hesham; Veeranna, Vikas; Afonso, Luis

    2007-08-01

    Recent studies have highlighted the existence of an 'obesity paradox' in patients undergoing coronary angiography, i.e., a high body mass Index (BMI) is associated with less severe coronary lesions. We sought to confirm the existence of this phenomenon in the US patient population. Study subjects included 770 consecutive patients (470 men, 428 African-Americans, 212 Caucasians) referred for coronary angiography to a tertiary care center. Duke myocardial jeopardy score, a prognostication tool predictive of 1-year mortality in coronary artery disease (CAD) patients, was assigned to angiographic data. Patients were classified according to their BMI (kg/m2) as normal (21-24), overweight (25-29), obesity class I (30-34), class II (35-39) and class III (40 or above). Patients in the increasing obesity class had a higher prevalence of diabetes, hypertension and dyslipidemia and were more likely to be women. A negative correlation was observed between BMI and age (R = - 0.15 p < 0.001) as well as between BMI and Duke Jeopardy score (r = - 0.07, p < 0.05) indicating that patients with higher BMI were referred for coronary angiography at a younger age, and had a lower coronary artery disease (CAD) burden. BMI was not an independent predictor of coronary lesion severity on multivariate stepwise linear regression analysis. Obese patients are referred for coronary angiography at an earlier age and have a lower CAD burden lending further credence to the existence of an apparent "obesity paradox". However, obesity per se, after adjustment for comorbidities, is not an independent predictor of severity of coronary artery disease. (c) 2007 Wiley Periodicals, Inc.

  1. Computerized classification of proximal occlusion in the left anterior descending coronary artery.

    PubMed

    Gregg, Richard E; Nikus, Kjell C; Zhou, Sophia H; Startt Selvester, Ronald H; Barbara, Victoria

    2010-01-01

    Proximal occlusion within the left anterior descending (LAD) coronary artery in patients with acute myocardial infarction leads to higher mortality than does nonproximal occlusion. We evaluated an automated program to detect proximal LAD occlusion. All patients with suspected acute coronary syndrome (n = 7,710) presenting consecutively to the emergency department of a local hospital with a coronary angiogram–confirmed flow-limiting lesion and notation of occlusion site were included in the study (n = 711). Electrocardiograms (ECGs) that met ST-segment elevation myocardial infarction (STEMI) criteria were included in the training set (n = 183). Paired angiographic location of proximal LAD and ECGs with ST elevation in the anterolateral region were used for the computer program development (n = 36). The test set was based on ECG criteria for anterolateral STEMI only without angiographic reports (n = 162). Tested against 2 expert cardiologists' agreed reading of proximal LAD occlusion, the algorithm has a sensitivity of 95% and a specificity of 82%. The algorithm is designed to have high sensitivity rather than high specificity for the purpose of not missing any proximal LAD in the STEMI population. Our preliminary evaluation suggests that the algorithm can detect proximal LAD occlusion as an additional interpretation to STEMI detection with similar accuracy as cardiologist readers.

  2. Shock Index Correlates with Extravasation on Angiographs of Gastrointestinal Hemorrhage: A Logistics Regression Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nakasone, Yutaka, E-mail: n-yutaka@cd5.so-net.ne.jp; Ikeda, Osamu; Yamashita, Yasuyuki

    We applied multivariate analysis to the clinical findings in patients with acute gastrointestinal (GI) hemorrhage and compared the relationship between these findings and angiographic evidence of extravasation. Our study population consisted of 46 patients with acute GI bleeding. They were divided into two groups. In group 1 we retrospectively analyzed 41 angiograms obtained in 29 patients (age range, 25-91 years; average, 71 years). Their clinical findings including the shock index (SI), diastolic blood pressure, hemoglobin, platelet counts, and age, which were quantitatively analyzed. In group 2, consisting of 17 patients (age range, 21-78 years; average, 60 years), we prospectively appliedmore » statistical analysis by a logistics regression model to their clinical findings and then assessed 21 angiograms obtained in these patients to determine whether our model was useful for predicting the presence of angiographic evidence of extravasation. On 18 of 41 (43.9%) angiograms in group 1 there was evidence of extravasation; in 3 patients it was demonstrated only by selective angiography. Factors significantly associated with angiographic visualization of extravasation were the SI and patient age. For differentiation between cases with and cases without angiographic evidence of extravasation, the maximum cutoff point was between 0.51 and 0.0.53. Of the 21 angiograms obtained in group 2, 13 (61.9%) showed evidence of extravasation; in 1 patient it was demonstrated only on selective angiograms. We found that in 90% of the cases, the prospective application of our model correctly predicted the angiographically confirmed presence or absence of extravasation. We conclude that in patients with GI hemorrhage, angiographic visualization of extravasation is associated with the pre-embolization SI. Patients with a high SI value should undergo study to facilitate optimal treatment planning.« less

  3. Relationship Between Coronary Contrast-Flow Quantitative Flow Ratio and Myocardial Ischemia Assessed by SPECT MPI.

    PubMed

    Smit, Jeff M; Koning, Gerhard; van Rosendael, Alexander R; Dibbets-Schneider, Petra; Mertens, Bart J; Jukema, J Wouter; Delgado, Victoria; Reiber, Johan H C; Bax, Jeroen J; Scholte, Arthur J

    2017-10-01

    A new method has been developed to calculate fractional flow reserve (FFR) from invasive coronary angiography, the so-called "contrast-flow quantitative flow ratio (cQFR)". Recently, cQFR was compared to invasive FFR in intermediate coronary lesions showing an overall diagnostic accuracy of 85%. The purpose of this study was to investigate the relationship between cQFR and myocardial ischemia assessed by single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI). Patients who underwent SPECT MPI and coronary angiography within 3 months were included. The cQFR computation was performed offline, using dedicated software. The cQFR computation was based on 3-dimensional quantitative coronary angiography (QCA) and computational fluid dynamics. The standard 17-segment model was used to determine the vascular territories. Myocardial ischemia was defined as a summed difference score ≥2 in a vascular territory. A cQFR of ≤0.80 was considered abnormal. Two hundred and twenty-four coronary arteries were analysed in 85 patients. Overall accuracy of cQFR to detect ischemia on SPECT MPI was 90%. In multivariable analysis, cQFR was independently associated with ischemia on SPECT MPI (OR per 0.01 decrease of cQFR: 1.10; 95% CI 1.04-1.18, p = 0.002), whereas clinical and QCA parameters were not. Furthermore, cQFR showed incremental value for the detection of ischemia compared to clinical and QCA parameters (global chi square 48.7 to 62.6; p <0.001). A good relationship between cQFR and SPECT MPI was found. cQFR was independently associated with ischemia on SPECT MPI and showed incremental value to detect ischemia compared to clinical and QCA parameters.

  4. Dynamic three-dimensional model of the coronary circulation

    NASA Astrophysics Data System (ADS)

    Lehmann, Glen; Gobbi, David G.; Dick, Alexander J.; Starreveld, Yves P.; Quantz, M.; Holdsworth, David W.; Drangova, Maria

    2001-05-01

    A realistic numerical three-dimensional (3D) model of the dynamics of human coronary arteries has been developed. High- resolution 3D images of the coronary arteries of an excised human heart were obtained using a C-arm based computed tomography (CT) system. Cine bi-plane coronary angiograms were then acquired from a patient with similar coronary anatomy. These angiograms were used to determine the vessel motion, which was applied to the static 3D coronary tree. Corresponding arterial bifurcations were identified in the 3D CT image and in the 2D angiograms. The 3D positions of the angiographic landmarks, which were known throughout the cardiac cycle, were used to warp the 3D image via a non-linear thin-plate spline algorithm. The result was a set or 30 dynamic volumetric images sampling a complete cardiac cycle. To the best of our knowledge, the model presented here is the first dynamic 3D model that provides a true representation of both the geometry and motion of a human coronary artery tree. In the future, similar models can be generated to represent different coronary anatomy and motion. Such models are expected to become an invaluable tool during the development of dynamic imaging techniques such as MRI, multi-slice CT and 3D angiography.

  5. The utility of postmortem computed tomography selective coronary angiography in parallel with autopsy.

    PubMed

    Inokuchi, Go; Yajima, Daisuke; Hayakawa, Mutsumi; Motomura, Ayumi; Chiba, Fumiko; Torimitsu, Suguru; Makino, Yohsuke; Iwase, Hirotaro

    2013-12-01

    Historically, coronary angiography of the isolated heart has played an important role in the detection of stenotic or occlusive lesions that are difficult to identify by autopsy alone. Meanwhile, although the application of multidetector computed tomography (MDCT) to forensic fields has accelerated recently, isolated single organ angiography with MDCT is rarely performed. In this article, we present an evaluation of postmortem selective coronary CT angiography of the isolated heart with MDCT and discuss its utility for autopsy. First, in a preliminary experiment using pig coronary artery, we examined the behavior of water soluble contrast material on postmortem computed tomography angiography (PMCTA) and found that better angiographic images were acquired when the viscosity of the contrast material was increased and CT was performed under conditions of sustained perfusion. Based on these results, we devised a selective coronary angiography procedure using a pressurized bag for drip infusion that can be performed easily, quickly, and at low cost. The angiographic images obtained provided useful supportive evidence of autopsy findings suggestive of ischemic heart disease. With active discussions underway in forensic fields on the proper use of postmortem computed tomography, PMCTA has also naturally attracted attention as it compensates for some of the shortcomings of CT alone. Although PMCTA typically involves whole-body angiography, if we view PMCTA as one of the many useful and supplementary tools available for autopsy, then isolated heart angiography continues to have utility in autopsy today.

  6. Recurrent syncope attributed to left main coronary artery severe stenosis.

    PubMed

    Li, Min; Zheng, Xinyi; Liu, Hua; Liu, Yujie

    2015-01-01

    Patients with acute coronary syndrome (ACS) rarely manifest as recurrent syncope due to malignant ventricular arrhythmia. We report a case of a 56-year-old Chinese male with complaints of paroxysmal chest burning sensation and distress for 2 weeks as well as loss of consciousness for 3 days. The electrocardiogram (ECG) revealed paroxysmal multimorphologic ventricular tachycardia during attack and normal heart rhythm during intervals. Coronary angiograph showed 90% stenosis in left main coronary artery and 80% stenosis in anterior descending artery. Two stents sized 4.0∗18 mm and 2.75∗18 mm were placed at left main coronary artery and anterior descending artery, respectively, during percutaneous coronary intervention (PCI). The patient was discharged and never had ventricular arrhythmia again during a 3-month follow-up since the PCI. This indicated that ventricular tachycardia was correlated with persistent severe myocardial ischemia. Coronary vasospasm was highly suspected to be the reason of the sudden attack and acute exacerbation. PCI is recommended in patients with both severe coronary artery stenosis and ventricular arrhythmia. Removing myocardial ischemia may stop or relieve ventricular arrhythmia and prevent cardiac arrest.

  7. Uric acid levels are associated with endothelial dysfunction and severity of coronary atherosclerosis during a first episode of acute coronary syndrome.

    PubMed

    Gaubert, Mélanie; Marlinge, Marion; Alessandrini, Marine; Laine, Marc; Bonello, Laurent; Fromonot, Julien; Cautela, Jennifer; Thuny, Franck; Barraud, Jeremie; Mottola, Giovanna; Rossi, Pascal; Fenouillet, Emmanuel; Ruf, Jean; Guieu, Régis; Paganelli, Franck

    2018-06-01

    The role of serum uric acid in coronary artery disease has been extensively investigated. It was suggested that serum uric acid level (SUA) is an independent predictor of endothelial dysfunction and related to coronary artery lesions. However, the relationship between SUA and severity of coronary atherosclerosis evaluated via endothelial dysfunction using peripheral arterial tone (PAT) and the reactive hyperhemia index (RHI) has not been investigated during a first episode of acute coronary syndrome (ACS). The aim of our study was to address this point. We prospectively enrolled 80 patients with a first episode of ACS in a single-center observational study. All patients underwent coronary angiography, evaluation of endothelial function via the RHI, and SUA measurement. The severity of the coronary artery lesion was assessed angiographically, and patients were classified in three groups based on the extent of disease and Gensini and SYNTAX scores. Endothelial function was considered abnormal if RHI < 1.67. We identified a linear correlation between SUA and RHI (R 2  = 0.66 P < 0.001). In multivariable analyses, SUA remained associated with RHI, even after adjustment for traditional cardiovascular risk factors and renal function. SUA was associated with severity of coronary artery disease. SUA is associated with severity of coronary atherosclerosis in patients with asymptomatic hyperuricemia. This inexpensive, readily measured biological parameter may be useful to monitor ACS patients.

  8. Coronary pressure notch: an early non-hyperemic visual indicator of the physiologic significance of a coronary artery stenosis.

    PubMed

    Holmes, David; Velappan, Priya; Kern, Morton J

    2004-11-01

    The disappearance of a dichrotic notch on the peripheral arterial pulse wave has been associated with significant peripheral vascular disease. A similar observation has not been reported in the distal coronary pressure waveform. The purpose of this study was to investigate the significance of a coronary pressure notch distal to a coronary stenosis and its relationship to fractional flow reserve. Ninety-seven patients with 131 angiographically indeterminate lesions (40-80% diameter narrowing) underwent FFR measurements for physiological significance. Hemodynamic tracings were recorded prior to the administration of adenosine and visually analyzed for the presence or absence of a dicrotic notch in the distal coronary artery pressure tracing. The stenoses were then divided into two groups based on the presence or absence of a notch. Of the 54 lesions without a distal coronary pressure notch, 31 had a FFR greater than or equal to 0.75 and of the 77 lesions with a notch, 75 had a FFR greater than or equal to 0.76. The sensitivity and specificity of a pressure notch was 94% and 74%, respectively, with positive and negative predictive values of 57% and 97%, respectively. The presence of a distal coronary pressure notch was predictive of a FFR greater than or equal to 0.76. The distal dicrotic pressure notch may be used as an additional parameter without requiring hyperemia for FFR measurements of uncertain clinical significance.

  9. Effect of Prior Aspirin Treatment on Patients With Acute Coronary Syndromes: Insights From the PROSPECT Study.

    PubMed

    Brener, Sorin J; Maehara, Akiko; Mintz, Gary S; Weisz, Giora; de Bruyne, Bernard; Serruys, Patrick W; Stone, Gregg W

    2015-12-01

    Prior aspirin treatment is considered a risk factor for adverse outcomes in acute coronary syndrome (ACS) patients. The relationships between aspirin pretreatment and findings on quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS), as well as clinical outcomes, are not well understood. In the PROSPECT trial, QCA and triple-vessel IVUS imaging were performed after successful percutaneous coronary intervention (PCI) of the culprit lesion(s) in ACS patients. We compared patients receiving aspirin within 7 days of enrollment to those naive to aspirin. Propensity score matching was performed to adjust for differences in baseline characteristics. Aspirin-pretreated patients (n = 236; 35%) were older and more likely to have known coronary disease than those without pretreatment (P≤.01 for all). Pretreated patients had more untreated non-culprit lesions with angiographic and IVUS characteristics predictive of future events (53.1% vs 38.6%; P<.001). There were no significant differences in overall major adverse cardiac event (MACE) rates at 3 years between the aspirin and no-aspirin groups (23.6% vs 18.8%, respectively; P=.17) in unadjusted or propensity-adjusted analyses. Prior aspirin use was not an independent predictor of MACE at 3 years (hazard ratio, 1.21; 95% confidence interval, 0.73-2.01; P=.45). In the PROSPECT trial, aspirin pretreatment identifies an older population with more advanced coronary disease. Aspirin pretreatment was not an independent predictor of MACE in ACS patients treated with an early invasive strategy. The extent to which aspirin pretreatment is a risk factor for adverse events after PCI in ACS should be revisited.

  10. Acute total left main stem occlusion treated with emergency percutaneous coronary intervention

    PubMed Central

    Mozid, A M; Sritharan, K; Clesham, G J

    2010-01-01

    Acute total occlusion of the left main stem (LMS) is a rare cause of myocardial infarction but carries a high risk of morbidity and mortality including presentation as sudden death. We describe the case of a 68-year-old woman who presented acutely with chest pain and ST segment elevation in lead aVR on her ECG suggestive of possible LMS occlusion. Emergency coronary angiography confirmed acute total LMS occlusion as well as an anomalous dominant right coronary artery. The patient underwent emergency percutaneous coronary intervention of the LMS with a good angiographic result and resolution of her symptoms. The patient was treated for acute left ventricular failure but made a gradual recovery and was discharged home 7 days after admission.

  11. Quantitative evaluation of collateral circulation in patients with previous myocardial infarction: relation to myocardial ischemia, angiographic appearance and functional improvement of myocardium.

    PubMed

    Vukcevic, Vladan; Beleslin, Branko; Ostojic, Miodrag; Stojkovic, Sinisa; Stankovic, Goran; Nedeljkovic, Milan; Orlic, Dejan; Djordjevic-Dikic, Ana; Stepanovic, Jelena; Giga, Vojislav; Arandjelovic, Aleksandra; Dikic, Miodrag; Kostic, Jelena; Nedeljkovic, Ivana; Nedeljkovic-Beleslin, Biljana; Saponjski, Jovica

    2009-04-01

    Evaluation of coronary pressures during angioplasty may functionally quantify collateral circulation. The aim of the study was to evaluate the relation between the amount of collateral circulation and development of myocardial ischemia during balloon occlusion, anatomic degree of collaterals, and functional improvement of myocardium. Study population consisted of 31 pts (mean age 53 +/- 7 years; 25 male) with previous myocardial infarction and significant one-vessel stenosis undergoing angioplasty. Collateral circulation was calculated as the ratio between distal coronary pressure during balloon occlusion (P(w)) and aortic pressure (P(a)). Angiographic appearance of collaterals was evaluated by Rentrop classification. Patients were evaluated by echo for functional improvement of myocardium in the follow-up period. Mean P(w)/P(a) was 0.24 +/- 0.10 (range of 0.07-0.51). Rentrop grade 0 of collaterals was present in 16 patients (52%), grade 1 in11 patients (35%), and grade 2 in 4 patients (13%). A mild correlation between angio and hemodynamic evaluation of collaterals was observed (r = 0.38, P = 0.035). In patients without ECG changes during angioplasty (21 pts, 68%), P(w)/P(a) was significantly higher in comparison to patients with ECG changes (0.28 +/- 0.09 vs. 0.15 +/- 0.06, P < 0.001; area under the curve 0.93). In patients with myocardial functional improvement during follow-up (21 pts, 68%), P(w)/P(a) was significantly higher than in the patients without echo improvement (0.26 +/- 0.10 vs. 0.18 +/- 0.08, P = 0.035). The amount of recruitable collaterals is not negligible even in the patients with no angio visible collaterals. Low values of P(w)/P(a) are associated with ECG changes during balloon occlusion. Higher P(w)/P(a) was associated with better functional improvement of myocardium.

  12. Reduced coronary flow and resistance reserve in primary scleroderma myocardial disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nitenberg, A.; Foult, J.M.; Kahan, A.

    1986-08-01

    The maximum coronary vasodilator capacity after intravenous dipyridamole (0.14 mg X kg-1 X min-1 X 4 minutes) was studied in seven patients with primary scleroderma myocardial disease and compared to that of seven control subjects. Hemodynamic data and left ventricular angiographic data were not different in the two groups. The coronary flow reserve was evaluated by the dipyridamole/basal coronary sinus blood flow ratio (D/B CSBF) and the coronary resistance reserve by the dipyridamole/basal coronary resistance ratio (D/B CR). Coronary reserve was greatly impaired in the group with primary scleroderma myocardial disease: D/B CSBF was lower than in the control groupmore » (2.54 +/- 1.37 vs 4.01 +/- 0.56, respectively; p less than 0.05) and D/B CR was higher than in the control group (0.47 +/- 0.25 vs 0.23 +/- 0.04, respectively; p less than 0.05). Such a decreased coronary flow and resistance reserve in patients with primary scleroderma myocardial disease was not explained by an alteration of left ventricular function. It may be an important contributing factor in the pathogenesis of primary scleroderma myocardial disease.« less

  13. Monocyte Chemoattractant Protein-1 as a Predictor of Coronary Atherosclerosis in Patients Receiving Coronary Angiography.

    PubMed

    Mahler, Simon A; Register, Thomas C; Riley, Robert F; D'Agostino, Ralph B; Stopyra, Jason P; Miller, Chadwick D

    2018-06-01

    Animal studies suggest that monocyte chemoattractant protein-1 (MCP-1) is a promising biomarker for coronary artery atherosclerosis (CAA), but human studies have been inconclusive. To determine potential relationships between plasma MCP-1 and CAA in patients with acute chest pain. A secondary analysis of 150 patients enrolled in emergency department chest pain risk stratification clinical investigations was conducted. Participants with stored blood and known coronary phenotypes (determined by coronary angiography) were selected using stratified randomization such that 50 patients were included into 3 groups: (1) no angiographic evidence of CAA, (2) nonobstructive CAA, and (3) obstructive CAA (stenosis ≥ 70%). Plasma MCP-1 levels were determined by enzyme-linked immunosorbent assay. The association between MCP-1 and obstructive CAA or any CAA was modeled using logistic regression. Variables in the unreduced model included age, sex, race, prior diagnosis of CAA or acute coronary syndrome, hyperlipidemia, hypertension, diabetes, smoking, and cardiac troponin I measurement. Among the 150 participants, 65.3% (98/150) had invasive coronary angiography and 34.7% (52/150) had coronary computed tomographic angiography. Myocardial infarction occurred in 27.3% (41/150) and coronary revascularization occurred in 26% (39/150) of the participants. Each 10 pg/mL increase in MCP-1 measurement was associated with an odds ratio of 1.12 (95% confidence interval, 1.06-1.19) for obstructive CAA. MCP-1 remained a significant predictor of obstructive CAA and any CAA after adjustment for age, sex, race, traditional cardiac risk factors, and cardiac troponin I. MCP-1 is independently associated with CAA among emergency department patients with chest pain.

  14. Short term results of percutaneous transluminal coronary angioplasty with the monorail technique: experience in the first 1000 patients.

    PubMed

    de Feyter, P J; Serruys, P W; van den Brand, M; Suryapranata, H; Beatt, K

    1990-04-01

    The monorail technique allows monitoring of all steps of the coronary angioplasty procedure by high quality coronary angiography; easy, rapid, and safe recrossing and redilatation of the lesion if necessary; and stepwise dilatation of a stenosis with sequential increase of size of balloons. Transstenotic pressure differences cannot, however, be measured through the narrow shaft of the standard monorail balloon catheter. The monorail technique was used in 1014 patients (820 men, 194 women; mean age 57.8 years (range 24 to 84]. The indication for coronary angioplasty was stable angina in 52%, unstable angina in 40%, and acute myocardial infarction in 8%. Single vessel coronary angioplasty was attempted in 78%, multilesion coronary angioplasty in 11%, and multivessel coronary angioplasty in 11%. Angiographic success (reduction of stenosis to less than 50% of the luminal diameter) of all attempted lesions was achieved in 93%. The technique was clinically successful--that is, angiographic success of all attempted lesions, no occurrence of a major complication (death, myocardial infarction, acute bypass surgery), and improvement of symptoms--in 92% and partially successful in 1.3%. The clinical success rates were similar for stable angina (91%) and unstable angina (94%), but were somewhat lower for acute myocardial infarction (88%). Failure without major complication occurred in 3.4% of the patients. Failure with a major complication occurred in 3.3% (death 0.3%, myocardial infarction 2.4%, and acute bypass surgery 2.3%). The total major complication rate was higher in unstable angina (4.2%) than in stable angina (3.0%). These results indicate that the monorail technique can be applied safely and effectively for coronary angioplasty of patients with stable angina, unstable angina, and acute myocardial infarction.

  15. Early clinical and angiographic outcome of the pedicled right internal thoracic artery graft to the left anterior descending artery.

    PubMed

    Al-Ruzzeh, Sharif; George, Shane; Bustami, Mahmoud; Nakamura, Koki; Ilsley, Charles; Amrani, Mohamed

    2002-05-01

    The left internal thoracic artery (LITA) graft to the left anterior descending (LAD) artery became the gold standard graft in coronary surgery. Subsequently, the right internal thoracic artery (RITA) graft was increasingly used. However, there is still some debate about the optimal way of using this conduit. The aim of the present study was to assess our experience in grafting the pedicled RITA graft to LAD in 212 consecutive patients. The records of 212 consecutive patients who underwent isolated coronary artery bypass grafting with the pedicled RITA graft to the LAD artery at Harefield Hospital between January 1998 and May 2001 were retrospectively reviewed. We approached the last 35 consecutive patients to obtain an angiographic control group. All 35 patients (16.5%) consented and, before discharge, underwent angiography to look at the quality of anastomoses and the patency of grafts. Successful catheterization and engagement of the RITA grafts was performed in 32 patients. Angiography showed that 32/32 (100%) of the RITA grafts were widely patent with excellent flow. The distal anastomoses of these RITA grafts were also satisfactory. There were no deaths among the study patients. Our results show that the use of the pedicled RITA graft to the LAD artery provides a good early clinical and angiographic outcome, and suggests that the pedicled RITA graft to the LAD artery is a good alternative to the pedicled LITA graft to the LAD artery.

  16. Relation between coronary arterial dominance and left ventricular ejection fraction after ST-segment elevation acute myocardial infarction in patients having percutaneous coronary intervention.

    PubMed

    Veltman, Caroline E; Hoogslag, Georgette E; Kharbanda, Rohit K; de Graaf, Michiel A; van Zwet, Erik W; van der Hoeven, Bas L; Delgado, Victoria; Bax, Jeroen J; Scholte, Arthur J H A

    2014-12-01

    The presence of a left dominant coronary artery system is associated with worse outcome after ST-segment elevation myocardial infarction (STEMI) compared with right dominance or a balanced coronary artery system. However, the association between coronary arterial dominance and left ventricular (LV) function at follow-up after STEMI is unclear. The present study aimed at evaluating the relation between coronary arterial dominance and LV ejection fraction (LVEF) shortly after STEMI and at 12-month follow-up. A total of 741 patients with STEMI (mean age 60 ± 11 years and 77% men) were evaluated with 2-dimentional echocardiography within 48 hours of admission (baseline) and at 12-month follow-up after STEMI. Coronary arterial dominance was assessed on the angiographic images obtained during primary percutaneous coronary intervention. A right, left, and balanced dominant coronary artery system was noted in 640 (86%), 58 (8%), and 43 (6%) patients, respectively. At baseline, significant difference in LV function was observed, with slightly lower LVEF in patients with a left dominant coronary artery system (LVEF 45 ± 8% vs 48 ± 9% and 50 ± 9%, for left dominant, right dominant, and balanced coronary artery system respectively, p = 0.03). However, at 12-month follow-up no differences in LV function or volumes were observed among the different coronary arterial dominance groups. In conclusion, patients with a left dominant coronary artery system had lower LVEF early after STEMI. At 12-month follow-up, differences in LVEF were no longer present among the different coronary arterial dominance groups. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Correlation of heart rate/ST slope and coronary angiographic findings.

    PubMed Central

    Balcon, R; Brooks, N; Layton, C

    1984-01-01

    The heart rate/ST slope was evaluated in 49 patients undergoing routine investigation for possible coronary artery disease. The slope correctly predicted the absence of any 75% stenoses in the seven patients to whom this applied; it was, however, correct for only four of 30 with one stenosis, one of 10 with two, and neither of the patients with three. Distinct slope ranges were not found, and the previously published ranges said to be specific for no significant stenosis and one, two, and three vessel disease were not. PMID:6466516

  18. Increased plasma soluble adhesion molecules; ICAM-1, VCAM-1, and E-selectin levels in patients with slow coronary flow.

    PubMed

    Turhan, Hasan; Saydam, Gul Sevim; Erbay, Ali Riza; Ayaz, Selime; Yasar, Ayse Saatci; Aksoy, Yuksel; Basar, Nurcan; Yetkin, Ertan

    2006-04-04

    Inflammation has been reported to be a major contributing factor to many cardiovascular events. In the present study, we aimed to evaluate plasma soluble adhesion molecules; intercellular adhesion molecule-1 (ICAM-1), vascular cell adhesion molecule-1 (VCAM-1) and E-selectin as possible indicators of endothelial activation or inflammation in patients with slow coronary flow. Study population included 17 patients with angiographically proven normal coronary arteries and slow coronary flow in all three coronary vessels (group I, 11 male, 6 female, mean age=48+/-9 years), and 20 subjects with angiographically proven normal coronary arteries without associated slow coronary flow (group II, 11 male, 9 female, mean age=50+/-8 years). Coronary flow rates of all patients and control subjects were documented by Thrombolysis In Myocardial Infarction frame count (TIMI frame count). All patients in group I had TIMI frame counts greater than two standard deviation above those of control subjects (group II) and, therefore, were accepted as exhibiting slow coronary flow. Serum levels of ICAM-1, VCAM-1, and E-selectin were measured in all patients and control subjects using commercially available ELISA kits. Serum ICAM-1, VCAM-1, and E-selectin levels of patients with slow coronary flow were found to be significantly higher than those of control subjects with normal coronary flow (ICAM-1: 545+/-198 ng/ml vs. 242+/-113 ng/ml respectively, p<0.001, VCAM-1: 2040+/-634 ng/ml vs. 918+/-336 ng/ml respectively, p<0.001, E-selectin: 67+/-9 ng/ml vs. 52+/-8 ng/ml respectively, p<0.001). Average TIMI frame count was detected to be significantly correlated with plasma soluble ICAM-1 (r=0.550, p<0.001), VCAM-1 (r=0.569, p<0.001) and E-selectin (r=0.443, p=0.006). Increased levels of soluble adhesion molecules in patients with slow coronary flow may be an indicator of endothelial activation and inflammation and are likely to be in the causal pathway leading to slow coronary flow.

  19. Endovascular image-guided treatment of in-vivo model aneurysms with asymmetric vascular stents (AVS): evaluation with time-density curve angiographic analysis and histology.

    PubMed

    Dohatcu, A; Ionita, C N; Paciorek, A; Bednarek, D R; Hoffmann, K R; Rudin, S

    2008-01-01

    In this study, we compare the results obtained from Time-Density Curve (TDC) analysis of angiographic imaging sequences with histological evaluation for a rabbit aneurysm model treated with standard stents and new asymmetric vascular stents (AVS) placed by image-guided endovascular deployment. AVSs are stents having a low-porosity patch region designed to cover the aneurysm neck and occlude blood flow inside. To evaluate the AVSs, rabbits with elastase-induced aneurysm models (n=20) were divided into three groups: the first (n=10) was treated with an AVS, the second (n=5) with a non-patch standard coronary stent, and third was untreated as a control (n=5). We used TDC analysis to measure how much contrast media entered the aneurysm before and after treatment. TDCs track contrast-media-density changes as a function of time over the region of interest in x-ray DSA cine-sequences. After 28 days, the animals were sacrificed and the explanted specimens were histologically evaluated. The first group showed an average reduction of contrast flow into the aneurysm of 95% after treatment with an AVS with fully developed thrombus at 28 days follow-up. The rabbits treated with standard stents showed an increase in TDC residency time after treatment and partial-thrombogenesis. The untreated control aneurysms displayed no reduction in flow and were still patent at follow-up. The quantitative TDC analysis findings were confirmed by histological evaluation suggesting that the new AVS has great potential as a definitive treatment for cerebro-vascular aneurysms and that angiographic TDC analysis can provide in-vivo verification.

  20. Endovascular image-guided treatment of in-vivo model aneurysms with asymmetric vascular stents (AVS): evaluation with time-density curve angiographic analysis and histology

    PubMed Central

    Dohatcu, A.; Ionita, C. N.; Paciorek, A.; Bednarek, D. R.; Hoffmann, K. R.; Rudin, S.

    2008-01-01

    In this study, we compare the results obtained from Time-Density Curve (TDC) analysis of angiographic imaging sequences with histological evaluation for a rabbit aneurysm model treated with standard stents and new asymmetric vascular stents (AVS) placed by image-guided endovascular deployment. AVSs are stents having a low-porosity patch region designed to cover the aneurysm neck and occlude blood flow inside. To evaluate the AVSs, rabbits with elastase-induced aneurysm models (n=20) were divided into three groups: the first (n=10) was treated with an AVS, the second (n=5) with a non-patch standard coronary stent, and third was untreated as a control (n=5). We used TDC analysis to measure how much contrast media entered the aneurysm before and after treatment. TDCs track contrast-media-density changes as a function of time over the region of interest in x-ray DSA cine-sequences. After 28 days, the animals were sacrificed and the explanted specimens were histologically evaluated. The first group showed an average reduction of contrast flow into the aneurysm of 95% after treatment with an AVS with fully developed thrombus at 28 days follow-up. The rabbits treated with standard stents showed an increase in TDC residency time after treatment and partial-thrombogenesis. The untreated control aneurysms displayed no reduction in flow and were still patent at follow-up. The quantitative TDC analysis findings were confirmed by histological evaluation suggesting that the new AVS has great potential as a definitive treatment for cerebro-vascular aneurysms and that angiographic TDC analysis can provide in-vivo verification. PMID:18958295

  1. Clinical characteristics and long-term progression of young patients with acute coronary syndrome in Brazil

    PubMed Central

    Soeiro, Alexandre de Matos; Fernandes, Felipe Lourenço; Soeiro, Maria Carolina Feres de Almeida; Serrano, Carlos Vicente; de Oliveira, Múcio Tavares

    2015-01-01

    Objective In Brazil, there are few descriptions in the literature on the angiographic pattern and clinical characteristics of young patients with acute coronary syndrome, despite the evident number of cases in the population. The objective of this study was to evaluate which clinical characteristics are most closely related to the acute coronary syndrome in young patients, and what long-term outcomes are in this population. Methods This is a prospective observational study with 268 patients aged under 55 years with acute coronary syndrome, carried out between May 2010 and May 2013. Data were obtained on demographics, laboratory test and angiography results, and the coronary treatment adopted. Statistical analysis was presented as percentages and absolute values. Results Approximately 57% were men and the median age was 50 years (30 to 55). The main risk factors were arterial hypertension (68%), smoking (67%), and dyslipidemia (43%). Typical pain was present in 90% of patients. In young individuals, 25.7% showed ST segment elevation. Approximately 56.5% of patients presented with a single-vessel angiographic pattern. About 7.1% were submitted to coronary bypass surgery, and 42.1% to percutaneous coronary angioplasty. Intrahospital mortality was 1.5%, and the combined event rate (cerebrovascular accident/stroke, cardiogenic shock, reinfarction, and arrhythmias) was 13.8%. After a mean follow-up of 10 months, mortality was 9.8%, while 25.4% of the patients had new ischemic events, and 37.3% required readmission to hospital. Conclusion In the short-term, young patients presented with mortality rates below what was expected when compared to the rates noted in other studies. However, there was a significant increase in the number of events in the 10-month follow-up. PMID:26466059

  2. Robert H. Goetz: the surgeon who performed the first successful clinical coronary artery bypass operation.

    PubMed

    Konstantinov, I E

    2000-06-01

    Robert H. Goetz performed the first successful clinical coronary artery bypass operation on May 2, 1960. He used a nonsuture technique to connect the right internal thoracic artery to the coronary artery by means of a modified Payr's cannula made of tantalum. The patency of the anastomosis was demonstrated angiographically and the patient remained free of angina pectoris for 1 year. It was an important and brave step forward, a step that was far ahead of its time. Unfortunately, his pioneering work was not appreciated and fell into oblivion.

  3. Three-dimensional reconstruction of coronary stents in vivo based on motion compensated X-ray angiography

    NASA Astrophysics Data System (ADS)

    Schäfer, Dirk; Movassaghi, Babak; Grass, Michael; Schoonenberg, Gert; Florent, Raoul; Wink, Onno; Klein, Andrew J. P.; Chen, James Y.; Garcia, Joel; Messenger, John C.; Carroll, John D.

    2007-03-01

    The complete expansion of the stent during a percutaneous transluminal coronary angioplasty (PTCA) procedure is essential for treatment of a stenotic segment of a coronary artery. Inadequate expansion of the stent is a major predisposing factor to in-stent restenosis and acute thrombosis. Stents are positioned and deployed by fluoroscopic guidance. Although the current generation of stents are made of materials with some degree of radio-opacity to detect their location after deployment, proper stent expansion is hard to asses. In this work, we introduce a new method for the three-dimensional (3D) reconstruction of the coronary stents in-vivo utilizing two-dimensional projection images acquired during rotational angiography (RA). The acquisition protocol consist of a propeller rotation of the X-ray C-arm system of 180°, which ensures sufficient angular coverage for volume reconstruction. The angiographic projections were acquired at 30 frames per second resulting in 180 projections during a 7 second rotational run. The motion of the stent is estimated from the automatically tracked 2D coordinates of the markers on the balloon catheter. This information is used within a motion-compensated reconstruction algorithm. Therefore, projections from different cardiac phases and motion states can be used, resulting in improved signal-to-noise ratio of the stent. Results of 3D reconstructed coronary stents in vivo, with high spatial resolution are presented. The proposed method allows for a comprehensive and unique quantitative 3D assessment of stent expansion that rivals current X-ray and intravascular ultrasound techniques.

  4. Pravastatin and endothelium dependent vasomotion after coronary angioplasty: the PREFACE trial

    PubMed Central

    Mulder, H; Schalij, M; Kauer, B; Visser, R; van Dijkman, P R M; Jukema, J; Zwinderman, A; Bruschke, A

    2001-01-01

    OBJECTIVE—To test the hypothesis that the 3-hydroxy-3-methylglutaryl coenzyme-A reductase inhibitor pravastatin ameliorates endothelium mediated responses of dilated coronary segments: the PREFACE (pravastatin related effects following angioplasty on coronary endothelium) trial.
DESIGN—A double blind, randomised, placebo controlled, multicentre study.
SETTING—Four hospitals in the Netherlands.
PATIENTS—63 non-smoking, non-hypercholesterolaemic patients scheduled for elective balloon angioplasty (pravastatin 34, placebo 29).
INTERVENTIONS—The effects of three months of pravastatin treatment (40 mg daily) on endothelium dependent vasomotor function were studied. Balloon angioplasty was undertaken one month after randomisation, and coronary vasomotor function tests using acetylcholine were performed two months after balloon angioplasty. The angiograms were analysed quantitatively.
MAIN OUTCOME MEASURES—The efficacy measure was the acetylcholine induced change in mean arterial diameter, determined in the dilated segment and in an angiographically normal segment of an adjacent non-manipulated coronary artery.
RESULTS—Increasing acetylcholine doses produced vasoconstriction in the dilated segments (p = 0.004) but not in the normal segments. Pravastatin did not affect the vascular response to acetylcholine in either the dilated segments (p = 0.09) or the non-dilated sites. Endothelium dependent vasomotion in normal segments was correlated with that in dilated segments (r = 0.47, p < 0.001). There were fewer procedure related events in the pravastatin group than in the placebo group (p < 0.05).
CONCLUSIONS—Endothelium dependent vasomotion in normal segments is correlated with that in dilated segments. A significant beneficial effect of pravastatin on endothelial function could not be shown, but in the dilated segments there was a trend towards a beneficial treatment effect in the pravastatin group.


Keywords: angioplasty

  5. Impact of very high pressure stent deployment on angiographic and long-term clinical outcomes in true coronary bifurcation lesions treated by the mini-crush stent technique: A single center experience.

    PubMed

    Gerbay, Antoine; Terreaux, Jeremy; Cerisier, Alexis; Vola, Marco; Isaaz, Karl

    Percutaneous coronary intervention (PCI) for bifurcation lesions (BL) using 2 stents technique is known to be associated with high rates of procedural failure especially on the side branch (SB) mainly due to stent incomplete apposition. Stent deployment at very high pressure (SDHP) may lead to better stent expansion and apposition. However, SDHP may also be at the origin of deeper wall injury resulting into major cardiac adverse events. No data are available on evaluation of SDHP in BL treated by a mini-crush stent technique. One hundred and thirteen consecutive patients underwent PCI for BL (Medina 1, 1, 1) using a mini-crush stent technique with SDHP defined as ≥20atm. An angiographic follow-up was performed at 6 month and clinical follow-up was obtained at a median of 3 years. Stent deployment mean pressures were 20±1.4atm (range 20-25) in the main vessel (MV) and 20±1.5atm (range 20-25) in SB. Simultaneous final kissing balloon was used in 92% of cases. PCI was successful in 100%. Angiographic follow-up was obtained in 83% of patients. Restenosis rate was 13% (12% restenosis in the SB) with only one case (0.8%) of SB probable thrombosis. Another case of late stent thrombosis occurred at a 3 years clinical follow-up. Compared with previously published studies in which stents were deployed at lower pressure, SDHP does not increase the restenosis rate in BL using mini-crush stent technique but seems to reduce the rate of stent thrombosis. Copyright © 2016 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  6. Contrasting patterns of coronary atherosclerosis in normocholesterolaemic smokers and patients with familial hypercholesterolaemia.

    PubMed Central

    Sugrue, D D; Thompson, G R; Oakley, C M; Trayner, I M; Steiner, R E

    1981-01-01

    An angiographic comparison was made of the extent and severity of coronary artery disease in 25 patients with heterozygous familial hypercholesterolaemia and 25 normocholesterolaemic patients with coronary artery disease in whom heavy cigarette consumption was the chief risk factor. The patients with familial hypercholesterolaemia were younger and included a much higher proportion of women than the smokers. Significantly more patients with familial hypercholesterolaemia had disease of the main stem of the left coronary artery (eight v none, p less than 0.05) and triple-vessel disease (18 v four, p less than 0.05). Disease affecting only distal vessels occurred in five smokers, whereas all the patients with familial hypercholesterolaemia showed a combination of proximal and distal lesions. These findings suggest that cigarette smoking and familial hypercholesterolaemia predispose to different patterns of coronary atheroma. Early coronary angiography with a view to coronary artery bypass surgery seems desirable in symptomatic patients with familial hypercholesterolaemia because of the common association of this disorder with life-threatening left main-stem disease. PMID:6797539

  7. “Spiral stenting”—creating a subintimal neo-luminal helix around a massively calcified ostial chronic total occlusion of the right coronary artery in a patient with recurrent ventricular tachycardia

    PubMed Central

    Valuckiene, Zivile; Neuser, Hans; Walter, Marlon; Gappmaier, Wolfgang; Kaiser, Thomas; Neumann, Franz-Josef; Akin, Ibrahim; Behnes, Michael

    2016-01-01

    This case report describes a successful percutaneous coronary intervention (PCI) of a severely calcified aorto-ostial chronic total occlusion (CTO) of the right coronary artery (RCA). The lesion was treated by a retrograde approach implementing long spiral subintimal wire tracking and final coronary stenting creating a subintimal neo-luminal helix around the natively occluded RCA. After 6 months of follow-up valuable angiographic results were proven. PMID:28066662

  8. 21 CFR 870.1650 - Angiographic injector and syringe.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Angiographic injector and syringe. 870.1650 Section 870.1650 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1650 Angiographic...

  9. 21 CFR 870.1650 - Angiographic injector and syringe.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Angiographic injector and syringe. 870.1650 Section 870.1650 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1650 Angiographic...

  10. Short term results of percutaneous transluminal coronary angioplasty with the monorail technique: experience in the first 1000 patients.

    PubMed Central

    de Feyter, P J; Serruys, P W; van den Brand, M; Suryapranata, H; Beatt, K

    1990-01-01

    The monorail technique allows monitoring of all steps of the coronary angioplasty procedure by high quality coronary angiography; easy, rapid, and safe recrossing and redilatation of the lesion if necessary; and stepwise dilatation of a stenosis with sequential increase of size of balloons. Transstenotic pressure differences cannot, however, be measured through the narrow shaft of the standard monorail balloon catheter. The monorail technique was used in 1014 patients (820 men, 194 women; mean age 57.8 years (range 24 to 84]. The indication for coronary angioplasty was stable angina in 52%, unstable angina in 40%, and acute myocardial infarction in 8%. Single vessel coronary angioplasty was attempted in 78%, multilesion coronary angioplasty in 11%, and multivessel coronary angioplasty in 11%. Angiographic success (reduction of stenosis to less than 50% of the luminal diameter) of all attempted lesions was achieved in 93%. The technique was clinically successful--that is, angiographic success of all attempted lesions, no occurrence of a major complication (death, myocardial infarction, acute bypass surgery), and improvement of symptoms--in 92% and partially successful in 1.3%. The clinical success rates were similar for stable angina (91%) and unstable angina (94%), but were somewhat lower for acute myocardial infarction (88%). Failure without major complication occurred in 3.4% of the patients. Failure with a major complication occurred in 3.3% (death 0.3%, myocardial infarction 2.4%, and acute bypass surgery 2.3%). The total major complication rate was higher in unstable angina (4.2%) than in stable angina (3.0%). These results indicate that the monorail technique can be applied safely and effectively for coronary angioplasty of patients with stable angina, unstable angina, and acute myocardial infarction. Images PMID:2337500

  11. Quantitative assessment of angiographic perfusion reduction using color-coded digital subtraction angiography during transarterial chemoembolization.

    PubMed

    Wang, Ji; Cheng, Jie-Jun; Huang, Kai-Yi; Zhuang, Zhi-Guo; Zhang, Xue-Bin; Chi, Jia-Chang; Hua, Xiao-Lan; Xu, Jian-Rong

    2016-03-01

    The aim of this study was to develop a quantitative measurement of perfusion reduction using color-coded digital subtraction angiography (ccDSA) to monitor intra-procedural arterial stasis during TACE. A total number of 35 patients with hepatocellular carcinoma who had undergone TACE were enrolled into the study. Pre- and post-two-dimensional digital subtraction angiography scans were conducted with same protocol and post-processed with ccDSA prototype software. Time-contrast-intensity (CI[t]) curve was obtained by region-of-interest (ROI) measurement on the generated ccDSA image. Quantitative 2D perfusion parameters time to peak, area under the curve (AUC), maximum upslope, and contrast intensity peak (CI-Peak) derived from the ROI-based CI[t] curve for pre- and post-TACE were evaluated to assess the reduction of antegrade blood flow and tumor blush. Relationships between 2D perfusion parameters, subjective angiographic chemoembolization endpoint (SACE) scale, and clinical outcomes were analyzed. Area normalized AUC and CI-Peak revealed significant reduction after the TACE (P < 0.0001). AUCnorm decreased from pre-procedure of 0.867 ± 0.242 to 0.421 ± 0.171 (P < 0.001) after completion of TACE. CI-Peaknorm was 0.739 ± 0.221 before TACE and 0.421 ± 0.174 (P < 0.001) after TACE. Tumor blood supply time slowed down obviously after embolization. A perfusion reduction either from AUCnorm or CI-Peaknorm ranging from 30% to 40% was associated with SACE level III and a reduction ranging from 60% to 70% was equivalent to SACE level IV. For intermediate reduction (SACE level III), better tumor response was found after TACE rather than a higher reduction (SACE level IV). ccDSA application provides an objective approach to quantify the perfusion reduction and subjectively evaluate the arterial stasis of antegrade blood flow and tumor blush caused by TACE.

  12. Noninvasive detection of coronary artery bypass graft patency by intravenous electron beam computed tomographic angiography.

    PubMed

    Yamakami, Shoji; Toyama, Junji; Okamoto, Mitsuhiro; Matsushita, Toyoaki; Murakami, Yoshimasa; Ogata, Masaki; Ito, Shigenori; Fukutomi, Tatsuya; Okayama, Naotsuka; Itoh, Makoto

    2003-11-01

    This study evaluates the usefullness of intravenous electron beam computed tomographic angiography (EBA) for the detection of coronary artery bypass graft patency in 43 patients (33 men and 10 women, mean age, 65 years) who had coronary artery bypass graft surgery. EBA was performed a few days before selective bypass graft angiography (SGA). Forty axial cross-sections of angiographic images of the heart were acquired consecutively by an electrocardiographic trigger signal at 40% of the RR interval, which corresponds to the end-systolic phase. EBA data were reconstructed as a three-dimensional shaded surface display of the heart and bypass grafts. Detectability of the patency of bypass gratis was evaluated, taking selective angiographic images of the bypass grafts as a gold standard. One hundred and nine grafts (96%) out of 114 grafts were subjected to evaluation: 37 grafts were left internal mammary artery grafts (LIMA), 7 were right internal mammary artery grafts (RIMA), 6 were gastroepiploic artery grafts (GEA), 7 were free gastroepiploic artery grafts with venous drainage (free-GEA), 7 were radial artery grafts (RAG), and 45 were saphenous vein gratis (SVG). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of EBA were 98%, 100%, 100%, 91%, and 98%, respectively. EBA sampled at the end-systolic period was determined to be useful for the detection of coronary artery bypass graft patency and occlusion.

  13. Percutaneous coronary intervention in Thammasat University Hospital: the first three-year experience.

    PubMed

    Piyayotai, Dilok; Hutayanon, Pisit

    2010-12-01

    To study the results of percutaneous coronary intervention (PCI) and in-hospital outcomes in cardiac catheterization laboratory, Thammasat University Hospital since May, 2006 until April, 2009. This is the prospective, single-center study. The consecutive patients who underwent PCI in Thammasat University Hospital since May 2006 to April 2009 were recruited in the study. Clinical data, angiographic data, and in-hospital outcomes were analyzed and demonstrated. Six hundred and seventeen patients undergoing 755 PCI procedures were enrolled in the study. 62.70% were male and 37.30% were female. Mean age was 65.45 +/- 11.21 years (range 33-97 years) and 20.10% were more than 75 years old. The indications for PCI were non-ST segment-elevation acute coronary syndrome (NSTEACS) (41.72%), chronic stable angina (25.32%), acute ST segment elevation myocardial infarction (STEMI) (8.87%), staged PCI (15.76%). The other indications were heart failure, cardiomyopathy, post-cardiac arrest and etc. The procedure was single vessel PCI in 73.25% and multivessel PCI in 26.75% (double vessels PCI 24.64% and triple vessels PCI 2.11%). According to lesion locations, 45.21% were left anterior descending (LAD) artery lesions, 30.09% were right coronary artery (RCA) lesions, 23.28% were left circumflex (LCX) artery lesions, 1.19% were left main (LM) lesions and 0.24% were graft lesions. The overall angiographic success rate was 95.57%. During hospital stay the major adverse events developed as death in 0.93%, periprocedural myocardial infarction in 3.17%, emergency coronary artery bypass graft in 0.53%, and stroke in 0.26%. During the first three years of PCI experience in Thammasat University Hospital, the overall success rate was high with low in-hospital adverse outcomes.

  14. Computer aided exercise electrocardiographic testing and coronary arteriography in patients with angina pectoris and with myocardial infarction.

    PubMed Central

    Angelhed, J E; Bjurö, T I; Ejdebäck, J; Selin, K; Schlossman, D; Griffith, L S; Bergstrand, R; Vedin, A; Wilhelmsson, C

    1984-01-01

    A set of electrocardiographic criteria for the diagnosis of coronary artery disease was evaluated in two different groups of patients examined by computer aided 12 lead exercise electrocardiographic stress testing and coronary arteriography. One group consisted of patients with severe angina pectoris and the other of patients who had suffered a myocardial infarction three years before the study. Angiographically determined categories of patients could be identified with satisfactory precision by the electrocardiographic criteria under test in the patients with angina pectoris but not in those with infarction. A new method of classifying patients on the basis of data from coronary arteriography improved the correlation with ST segment analysis compared with conventional classification. PMID:6743432

  15. Accuracy of computed tomographic angiography for stenosis quantification using quantitative coronary angiography or intravascular ultrasound as the gold standard.

    PubMed

    Joshi, Subodh B; Okabe, Teruo; Roswell, Robert O; Weissman, Gaby; Lopez, Cristian F; Lindsay, Joseph; Pichard, Augusto D; Weissman, Neil J; Waksman, Ron; Weigold, Wm Guy

    2009-10-15

    Computed tomographic angiography (CTA) is considered to have limited accuracy for quantifying exact percent diameter stenosis in coronary arteries. However, most studies evaluating CTA use quantitative coronary angiography (QCA) as the gold standard, a technique with its own limitations. We sought to determine whether CTA measurements of stenosis severity correlate better with intravascular ultrasound (IVUS) than with QCA. Luminal dimensions of 67 de novo coronary lesions were measured by CTA, IVUS, and QCA. IVUS was performed when lesion severity by angiography was equivocal. Mean percent diameter stenosis by QCA was 51 +/- 9.8% and mean IVUS minimal luminal area was 3.8 +/- 1.8 mm(2). There was a moderate correlation between CTA minimal luminal area and IVUS minimal luminal area (r(2) = 0.41, p <0.001), but no relation between CTA and QCA measurements of minimal luminal diameter (r(2) = 0.01, p = 0.57) or diameter stenosis (r(2) = 0.02, p = 0.31). There was also no relation between IVUS minimal luminal area and QCA diameter stenosis (r(2) = 0.01, p = 0.50). When lesions with moderate or severe calcification were excluded, the correlation between CTA minimal luminal area and IVUS minimal luminal area was good (r(2) = 0.68, p <0.001). In conclusion, in this cohort of patients with intermediate-grade lesions on cardiac catheterization, absolute measurements of stenosis severity on CTA correlated with IVUS but not with QCA. Our findings suggest that limitations of quantitative coronary angiography as a gold standard need to be considered in studies evaluating the accuracy of coronary CTA.

  16. Acute effects of intracoronary nitroglycerin and diltiazem in coronary slow flow phenomenon.

    PubMed

    Ozdogru, Ibrahim; Zencir, Cemil; Dogan, Ali; Orscelik, Ozcan; Inanc, Mehmet Tugrul; Celik, Ahmet; Gur, Mustafa; Elbasan, Zafer; Kalay, Nihat; Oguzhan, Abdurrahman

    2013-01-01

    The coronary slow flow phenomenon (CSFP) is a coronary microvascular disorder angiographically defined by delayed opacification of the distal vasculature in the absence of obstructive coronary artery disease. We aimed to investigate and compare the effects of intracoronary nitrate and diltiazem on thrombolysis in myocardial infarction frame count (TFC) in patients with CSFP during coronary angiography. Sixty patients with CSFP were randomly divided into 2 groups. The first group is nitroglycerin group with 30 patients (22 men; mean [SD] age, 50 [12] years), and the second is diltiazem group with 30 patients (27 men; mean age, 54 ± 11 years); intracoronary 5-mg diltiazem or 250-μg nitroglycerin was administered. Heart rate, systolic and diastolic blood pressures, and TFCs in all 3 coronaries were recorded before and after administering these medications. After nitroglycerin administration, systolic and diastolic blood pressures decreased, heart rates significantly increased, and TFCs decreased in all coronaries (P < 0.001 for 3 coronaries). After the application of intracoronary 5-mg diltiazem, heart rate, systolic and diastolic blood pressures, and TFCs were found significantly lower than predrug values (P < 0.001 for all values). When the percent TFC reductions, after the application of intracoronary diltiazem or nitroglycerin, in left anterior descending coronary artery, circumflex coronary artery, and right coronary artery were evaluated, diltiazem significantly reduced the TFCs of the left anterior descending coronary artery and circumflex coronary artery compared with nitroglycerin (P < 0.01 for both coronaries). Both intracoronary diltiazem and nitroglycerin improve the TFCs in CSFP, and intracoronary diltiazem is superior to nitroglycerin in reducing TFCs in CSFP.

  17. Paraoxonase 1 (Q192R) gene polymorphism, coronary heart disease and the risk of a new acute coronary event.

    PubMed

    Martínez-Quintana, Efrén; Rodríguez-González, Fayna; Medina-Gil, José María; Garay-Sánchez, Paloma; Tugores, Antonio

    Paraoxonase 1 (PON1) plays a major role in the oxidation of low density lipoprotein and in the prevention of coronary atherogenesis. In this context, coding region polymorphisms of PON1 gene, responsible for the enzyme activity, has become of interest as a marker for atherogenesis. A study and follow-up was conducted on 529 patients with an acute coronary event in order to assess the association between the PON1 Q192R (rs662;A/G) polymorphism, the type of acute coronary syndrome, cardiovascular risk factors (arterial hypertension, diabetes mellitus, dyslipidaemia, and smoking), the extent and severity of coronary atherosclerosis, and the medium-term clinical follow-up. The QQ genotype was found in 245 (46.3%) patients, with 218 (41.2%) patients showing the QR genotype, and 66 (14.5%) patients had the RR genotype. No significant differences were found between the QQ and QR/RR genotypes as regards the clinical characteristics, the analytical data, and the angiographic variables. Similarly, Kaplan-Meier survival analysis showed no significant differences in presenting with a new acute coronary event (p=0.598), cardiac mortality (p=0.701), stent thrombosis (p=0.508), or stent re-stenosis (p=0.598) between QQ and QR/RR genotypes during the follow-up period (3.3±2.2 years). In patients with an acute coronary syndrome, the PON1 Q192R genotypes did not influence the risk of suffering a new acute coronary event during the medium-term follow-up. Copyright © 2016 Sociedad Española de Arteriosclerosis. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. Coronary Revascularization in Children at a Mexican Cardiac Center: Thirteen-Year Outcomes.

    PubMed

    Ramírez-Marroquín, Samuel E; Iturriaga-Hernández, Alejandra; Calderón-Colmenero, Juan; Benita-Bordes, Antonio; Cervantes-Salazar, Jorge L

    2017-09-01

    The indications for pediatric coronary revascularization are diverse. There are a large proportion of patients with sequelae of severe inflammatory diseases such as Kawasaki disease, and other less common causes. Retrospective review of ten pediatric patients undergoing coronary artery bypass surgery from January 2004 to December 2016. Ten children and adolescents ranging in age from 2 to 17 (median, 6) years at operation were followed up for as long as 13 years with a median follow-up of 2 years. The surgical indications include ischemia symptoms and/or coronary stenosis angiographically documented. Diagnoses include Kawasaki disease, anomalous origin of the left coronary artery from the pulmonary artery, and iatrogenic lesion of the right coronary artery. All the surgical procedures were performed with cardiopulmonary bypass with crystalloid cardioplegic arrest. The number of distal anastomoses was 1.6 per patient, and the left internal thoracic artery was used in one patient, the right internal thoracic artery in four patients, bilateral internal thoracic artery in four patients, and bilateral internal thoracic artery plus left radial artery in one patient, most frequently for right coronary artery revascularization. The patients underwent noninvasive diagnostic study during follow-up to evaluate their coronary status. The ten patients had no symptoms, and there was no mortality. Although survival was excellent after pediatric coronary bypass in our center, we need to continue the follow-up. Coronary revascularization by means of arterial grafting is a safe and reliable surgical modality for coronary disease in children.

  19. Coronary flow reserve/diastolic function relationship in angina-suffering patients with normal coronary angiography.

    PubMed

    Anchisi, Chiara; Marti, Giuliano; Bellacosa, Ilaria; Mary, David; Vacca, Giovanni; Marino, Paolo; Grossini, Elena

    2017-05-01

    Coronary blood flow and diastolic function are well known to interfere with each other through mechanical and metabolic mechanisms. We aimed to assess the relationship between coronary flow reserve (CFR) and diastolic dysfunction in patients suffering from angina but with normal coronary angiography. In 16 patients with chest pain and angiographically normal coronary arteries, CFR was measured using transthoracic echo-Doppler by inducing hyperemia through dipyridamole infusion. Diastolic function (E/A, deceleration time, isovolumetric relaxation time [IVRT], propagation velocity [Vp]) and left ventricular mass were evaluated by means of two-dimensional transthoracic echocardiography. The patients were initially divided into two groups on the grounds of CFR only (ACFR: altered CFR, n = 9; NACFR: unaltered CFR, n = 7). Thereafter they were divided into four groups on the grounds of CFR and diastolic function (NN: normal; AA: altered CFR/diastole; AN: altered CFR/normal diastole; NA: normal CFR/altered diastole). Most of the subjects were scheduled in AA (n = 8) or NA (n = 5) groups, which were taken into consideration for further analysis. Patients were not different regarding various risk factors. ACFR and AA patients were older with normal body weight in comparison with NACFR and NA patients (P < 0.05). In the AA group, CFR and diastolic variables were found to be related to each other. Diastolic dysfunction and reduced CFR were correlated in patients with concomitant alterations of those variables only. Because most risk factors were shared with patients with altered diastolic properties only, our findings could represent a direct relationship between altered CFR and diastole.

  20. Association of NT-proBNP and Multiple Biomarkers with Severity of Angiographic Coronary Artery Disease in Diabetic and Pre-Diabetic Chinese Patients

    PubMed Central

    Fang, Zhou; Bao, Yuanyuan; Ding, Wei; Luo, Xinping; Hu, Renming

    2011-01-01

    Background Little is known about the plasma levels of N-terminal pro-brain natriuretic peptide (NT-proBNP), and the relationship between the severity of coronary heart disease (CHD) with NT-proBNP and multiple biomarkers in diabetic and pre-diabetic patients, compared to individuals with normal glucose levels. Methods Four hundred and fifteen consecutive Chinese patients of both sexes were assigned to three groups on the basis of the new hemoglobin (Hb) A1c (HbA1c) cut-off points for diagnosis of diabetes and pre-diabetes. The three groups were divided into tertiles according to NT-proBNP, hs-CRP, cystatin C, and troponin T levels. Gensini scores were compared among the three groups and biomarker tertiles. Receiver operating characteristic (ROC) curves were used to obtain the angiographic CHD cut-off points for each biomarker. Stepwise multivariate linear correlation analysis was applied to examine the association between the severity of CHD and biomarker levels. Results Gensini scores increased with increasing biomarker tertile levels and HbA1c. Gensini scores were significantly different in the middle and upper NT-proBNP tertiles of the diabetic, pre-diabetic and control groups. NT-proBNP had the highest positive and negative predictive values and area under the curve for CHD. Only NT-proBNP was identified as an independent variable for Gensini score. Conclusions Plasma NT-proBNP may be an important biomarker to evaluate the severity of CHD and screen for CHD in diabetic or pre-diabetic patients. PMID:21857933

  1. Holmium:YAG laser coronary angioplasty in patients with lesions not ideal for balloon angioplasty

    NASA Astrophysics Data System (ADS)

    Miyazaki, Shunichi; Nonogi, Hiroshi; Goto, Yoichi; Itoh, Akira; Ozono, Keizaburo; Daikoku, Satoshi; Haze, Kazuo

    1993-06-01

    Conventional balloon coronary angioplasty has limitations for application on particular lesions, such as lesions near the left main trunk (LMT), ostial location, and highly eccentric lesions. Hence, efficacy of newly developed Holmium YAG laser coronary angioplasty (HLCA) was assessed for 24 patients with angina. Adjunctive balloon angioplasty was performed for 21 of 24 lesions. Delivered energy ranged from 1.5 to 2.5 watts/pulse and the total exposure time ranged from 6 to 32 seconds. Laser success, defined as 20% reduction of stenotic ratio, was obtained in 16 of 24 (67%) and overall procedural success rate was 92%. Follow up coronary angiography after 3 months showed restenosis in 9 of 19 patients (47%). HLCA is an acutely effective treatment for lesions identified as not ideal for balloon angioplasty. However, angiographical restenosis rate is similar to the conventional balloon angioplasty and a highly calcified complex lesion may not be a candidate for the treatment of HLCA, because of a potential risk of coronary perforation.

  2. Reality of obesity paradox: Results of percutaneous coronary intervention in Middle Eastern patients.

    PubMed

    Jarrah, Mohamad; Hammoudeh, Ayman J; Khader, Yousef; Tabbalat, Ramzi; Al-Mousa, Eyas; Okkeh, Osama; Alhaddad, Imad A; Tawalbeh, Loai Issa; Hweidi, Issa M

    2018-04-01

    Objective The aim of this study was to assess the baseline clinical characteristics, coronary angiographic features, and adverse cardiovascular events during hospitalization and at 1 year of follow-up in obese patients compared with overweight and normal/underweight patients. Methods A prospective, multicenter study of consecutive patients undergoing percutaneous coronary intervention was performed. Results Of 2425 enrolled patients, 699 (28.8%) were obese, 1178 (48.6%) were overweight, and 548 (22.6%) were normal/underweight. Obese patients were more likely to be female and to have a higher prevalence of diabetes, hypertension, hypercholesterolemia, or previous percutaneous coronary intervention. Acute coronary syndrome was the indication for percutaneous coronary intervention in 77.0% of obese, 76.4% of overweight, and 77.4% of normal/underweight patients. No significant differences in the prevalence of multi-vessel coronary artery disease or multi-vessel percutaneous coronary intervention were found among the three groups. Additionally, no significant differences were found in stent thrombosis, readmission bleeding rates, or cardiac mortality among the three groups during hospitalization, at 1 month, and at 1 year. Conclusion The major adverse cardiovascular event rate was the same among the three groups throughout the study period. Accordingly, body mass index is considered a weak risk factor for cardiovascular comorbidities in Arab Jordanian patients.

  3. Brachial artery vasoreactivity is associated with cross-sectional and longitudinal anatomical measures of atherosclerosis in postmenopausal women with coronary artery disease

    PubMed Central

    Gatto, Nicole M.; Hodis, Howard N.; Liu, Chao-Ran; Liu, Chi-Hua; Mack, Wendy J.

    2009-01-01

    Background The diagnostic and prognostic importance of brachial artery flow-mediated dilation (BFMD) for cardiovascular disease (CVD) is not certain and associations between BFMD and recognized measures of atherosclerosis have not been well established. Methods We investigated cross-sectional and longitudinal correlations between repeated measures of BFMD and quantitative coronary artery angiographic (QCA) measurements of average percent diameter stenosis, number of lesions and minimum luminal diameter (MLD), and ultrasonographic measurement of carotid artery intima-media thickness (CIMT) in an ethnically diverse cohort of postmenopausal women (n = 132) with coronary artery disease (CAD). Subjects were participants in a 3-year randomized, placebo-controlled clinical trial, testing the efficacy of hormone therapy on atherosclerosis progression. Associations between BFMD and QCA measures, and between BFMD and CIMT were examined using measurements from the same study visit. Results BFMD was significantly inversely correlated with coronary artery stenosis at baseline (β = −1.21% [S.E.(β) = 0.38], p = 0.002). BFMD levels significantly predicted rate of change in CIMT over the trial period (β = −0.76 μm/year [S.E.(β) = 0.29], p = 0.008). Conclusions Physiological and anatomical measures of atherosclerosis are correlated among postmenopausal women with CAD, which provides some validation of BFMD as a measure of atherosclerosis in high-risk populations. PMID:17803999

  4. Coronary angioplasty with second generation Monorail catheters.

    PubMed

    Pande, A K; Meier, B; Urban, P; Villavicencio, R; de la Serna, F; Moles, V

    1991-07-01

    The Monorail system (Schneider) consists of a balloon catheter in which the guidewire passes through the balloon itself, exits the catheter proximal to the balloon, and runs alongside its small shaft (3 French) through the length of the guiding catheter. It offers distinct advantages over conventional systems of coronary angioplasty. It facilitates contrast injections and permits rapid balloon exchanges. This system was used for coronary angioplasty in 273 unselected consecutive patients (age 59 +/- 10, mean 35 to 73 years). There were 216 patients (84%) undergoing single-vessel and 57 patients (16%) with multi-vessel coronary angioplasty. A total of 335 coronary stenoses were dilated, which included 35 total occlusions. The size of balloon used ranged from 2.0 to 4.25 mm (3.0 +/- 0.5 mm) and the severity of stenosis was 85 +/- 11%. Technical success was defined as a residual stenosis of less than 50% as determined angiographically. Clinical success was defined as technical success, and absence of a major inhospital complication defined as absence of myocardial infarction, lack of need for coronary arterial bypass surgery, and survival. The Monorail system was technically successful in 294/300 stenotic lesions (98%). It was clinically successful for 281 lesions (94%). Of the 35 total occlusions, technical success was obtained in 25 (71%). The residual stenosis of successful cases was 26 +/- 21%. The Monorail system was also successful in 5 patients with stenosis of more than 90% in whom conventional systems failed. The complications included acute occlusion causing acute myocardial infarction in 13 cases (5%), emergency coronary arterial bypass surgery in 1 patient (0.4%), and death in 4 patients (1.5%).(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Angle-independent measure of motion for image-based gating in 3D coronary angiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lehmann, Glen C.; Holdsworth, David W.; Drangova, Maria

    2006-05-15

    The role of three-dimensional (3D) image guidance for interventional procedures and minimally invasive surgeries is increasing for the treatment of vascular disease. Currently, most interventional procedures are guided by two-dimensional x-ray angiography, but computed rotational angiography has the potential to provide 3D geometric information about the coronary arteries. The creation of 3D angiographic images of the coronary arteries requires synchronization of data acquisition with respect to the cardiac cycle, in order to minimize motion artifacts. This can be achieved by inferring the extent of motion from a patient's electrocardiogram (ECG) signal. However, a direct measurement of motion (from the 2Dmore » angiograms) has the potential to improve the 3D angiographic images by ensuring that only projections acquired during periods of minimal motion are included in the reconstruction. This paper presents an image-based metric for measuring the extent of motion in 2D x-ray angiographic images. Adaptive histogram equalization was applied to projection images to increase the sharpness of coronary arteries and the superior-inferior component of the weighted centroid (SIC) was measured. The SIC constitutes an image-based metric that can be used to track vessel motion, independent of apparent motion induced by the rotational acquisition. To evaluate the technique, six consecutive patients scheduled for routine coronary angiography procedures were studied. We compared the end of the SIC rest period ({rho}) to R-waves (R) detected in the patient's ECG and found a mean difference of 14{+-}80 ms. Two simultaneous angular positions were acquired and {rho} was detected for each position. There was no statistically significant difference (P=0.79) between {rho} in the two simultaneously acquired angular positions. Thus we have shown the SIC to be independent of view angle, which is critical for rotational angiography. A preliminary image-based gating strategy that employed

  6. Increased Arterial Stiffness after Coronary Artery Revascularization Correlates with Serious Coronary Artery Lesions and Poor Clinical Outcomes in Patients with Chronic Kidney Disease

    PubMed Central

    Zhu, Zhengbin; Yan, Zijun; Zhang, Lin; Du, Run; Zhu, Jinzhou; Zuo, Junli; Chu, Shaoli; Shen, Weifeng; Zhang, Ruiyan

    2014-01-01

    Objectives This study aimed to clarify the relationship between arterial stiffness and coronary artery lesions as well as their influence on long-term outcomes after coronary artery revascularization in patients with chronic kidney disease (CKD). Methods A total of 205 patients who had a coronary angiography and received coronary artery revascularization on demand were enrolled and followed up for 5 years. Demographic and clinical indicators, arterial stiffness indexes, angiographic characteristics and the Gensini score (GS) were recorded at baseline. Major adverse cardiac events (MACE), including cardiac death and repeat coronary artery revascularization, that occurred during the 5 years of follow-up were also recorded. Results All indexes reflecting the degree of arterial stiffness, including PWV, C1, C2, CSBP, CDBP, AP and Aix, were significantly higher in CKD than in non-CKD patients (all p < 0.05). Patients with CKD also had a higher rate of coronary artery disease and a higher GS (p < 0.05 and p < 0.01, respectively). Logistic regression analysis revealed CKD to be an independent risk factor for increased arterial stiffness (OR = 2.508, 95% CI 1.308-4.808, p = 0.006). During follow-up, CKD patients with PWV >13 m/s or Aix@75 >30 had a significantly higher MACE occurrence rate after coronary artery revascularization (both p < 0.05). Conclusion These results highlight that CKD and arterial stiffness correlate with the severity of coronary artery lesions. CKD patients with impaired arterial stiffness have poor clinical outcomes, suggesting a further clinical use of the arterial stiffness index as a surrogate of worse cardiovascular prognosis in CKD than in non-CKD patients. PMID:25737692

  7. The unique value of cardiovascular magnetic resonance in patients with suspected acute coronary syndrome and culprit-free coronary angiograms.

    PubMed

    Panovský, Roman; Borová, Júlia; Pleva, Martin; Feitová, Věra; Novotný, Petr; Kincl, Vladimír; Holeček, Tomáš; Meluzín, Jaroslav; Sochor, Ondřej; Štěpánová, Radka

    2017-06-28

    Patients with chest pain, elevated troponin, and unobstructed coronary disease present a clinical dilemma. The purpose of this study was to investigate the incremental diagnostic value of cardiovascular magnetic resonance (CMR) in a cohort of patients with suspected acute coronary syndrome (ACS) and unobstructed coronary arteries. Data files of patients meeting the inclusion criteria in two cardiology centres were searched and analysed. The inclusion criteria included: 1) thoracic pain suspected with ACS; 2) a significant increase in the high-sensitive Troponin T value; 3) ECG changes; 4) coronary arteries without any significant stenosis; 5) a CMR examination included in the diagnostic process; 6) an uncertain diagnosis before the CMR exam; and 7) the absence of known CMR and contrast media contraindications. Special attention was paid to the benefits of CMR in determining the final diagnosis. In total, 136 patients who underwent coronary angiography for chest pain were analysed. The most frequent underlying causes were myocarditis (38%) and perimyocarditis (18%), followed by angiographically unrecognised acute myocardial infarction (18%) and Takotsubo cardiomyopathy (15%). The final diagnosis remained unclear in 6% of the patients. The contribution of CMR in determining the final diagnosis determination was crucial in 57% of the patients. In another 35% of the patients, CMR confirmed the suspicion and, only 8% of the CMR examinations did not help at all and had no influence on diagnosis or treatment. CMR provided a powerful incremental diagnostic value in the cohort of patients with suspected ACS and unobstructed coronary arteries. CMR is highly recommended to be incorporated as an inalienable part of the diagnostic algorithms in these patients.

  8. Preintervention lesion remodelling affects operative mechanisms of balloon optimised directional coronary atherectomy procedures: a volumetric study with three dimensional intravascular ultrasound

    PubMed Central

    von Birgelen, C; Mintz, G; de Vrey, E A; Serruys, P; Kimura, T; Nobuyoshi, M; Popma, J; Leon, M; Erbel, R; de Feyter, P J

    2000-01-01

    AIMS—To classify atherosclerotic coronary lesions on the basis of adequate or inadequate compensatory vascular enlargement, and to examine changes in lumen, plaque, and vessel volumes during balloon optimised directional coronary atherectomy procedures in relation to the state of adaptive remodelling before the intervention.
DESIGN—29 lesion segments in 29 patients were examined with intravascular ultrasound before and after successful balloon optimised directional coronary atherectomy procedures, and a validated volumetric intravascular ultrasound analysis was performed off-line to assess the atherosclerotic lesion remodelling and changes in plaque and vessel volumes that occurred during the intervention. Based on the intravascular ultrasound data, lesions were classified according to whether there was inadequate (group I) or adequate (group II) compensatory enlargement.
RESULTS—There was no significant difference in patient and lesion characteristics between groups I and II (n = 10 and 19), including lesion length and details of the intervention. Quantitative coronary angiographic data were similar for both groups. However, plaque and vessel volumes were significantly smaller in group I than in II. In group I, 9 (4)% (mean (SD)) of the plaque volume was ablated, while in group II 16 (11)% was ablated (p = 0.01). This difference was reflected in a lower lumen volume gain in group I than in group II (46 (18) mm3 v 80 (49) mm3 (p < 0.02)).
CONCLUSIONS—Preintervention lesion remodelling has an impact on the operative mechanisms of balloon optimised directional coronary atherectomy procedures. Plaque ablation was found to be particularly low in lesions with inadequate compensatory vascular enlargement.


Keywords: intravascular ultrasound; ultrasonics; remodelling; coronary artery disease; atherectomy PMID:10648496

  9. Does lung ischemia and reperfusion have an impact on coronary flow? A quantitative coronary blood-flow analysis with inflammatory cytokine profile†

    PubMed Central

    Karapanos, Nikolaos Tsirikos; Wettstein, Peter J.; Li, Zhuo; Huebner, Marianne; Park, Soon J.; Deschamps, Claude; Cassivi, Stephen D.

    2012-01-01

    OBJECTIVE Ischemia-reperfusion (IR) injury remains a major cause of early morbidity and mortality after lung transplantation with poorly documented extrapulmonary repercussions. To determine the hemodynamic effect due to lung IR injury, we performed a quantitative coronary blood-flow analysis in a swine model of in situ lung ischemia and reperfusion. METHODS In 14 healthy pigs, blood flow was measured in the ascending aorta, left anterior descending (LAD), circumflex (Cx), right coronary artery (RCA), right common carotid artery (RCCA), and left internal mammary artery (LIMA), along with left-and right-ventricular pressures (LVP and RVP), aortic pressure (AoP), and pulmonary artery pressure (PAP). Cardiac Troponin (cTn), interleukin 6 and 10 (IL-6 and IL-10), and tumor necrosis factor A (TNF-A) were measured in coronary sinus blood samples. The experimental (IR) group (n = 10) underwent 60 min of lung ischemia followed by 60 min of reperfusion by clamping and releasing the left pulmonary hilum. Simultaneous measurements of all parameters were made at baseline and during IR. The control group (n = 4) had similar measurements without lung IR. RESULTS In the IR group, total coronary flow (TCF = LAD + Cx + RCA blood-flow) decreased precipitously and significantly from baseline (113 ± 41 ml min”1) during IR (p < 0.05), with the lowest value observed at 60 min of reperfusion (-37.1%, p < 0.003). Baseline cTn (0.08 ± 0.02 ng ml−1) increased during IR and peaked at 45 min of reperfusion (+138%, p < 0.001). Baseline IL-6 (9.2 ± 2.17 pg ml−1) increased during IR and peaked at 60 min of reperfusion (+228%, p < 0.0001). Significant LVP drop at 5 min of ischemia ( p < 0.05) was followed by a slow return to baseline at 45 min of ischemia. A second LVP drop occurred at reperfusion ( p < 0.05) and persisted. Conversely, RVP increased throughout ischemia (p < 0.05) and returned toward baseline during reperfusion. Coronary blood flow and hemodynamic

  10. The mixability of angiographic contrast with arterial blood

    PubMed Central

    Lieber, Baruch B.; Sadasivan, Chander; Hao, Qing; Seong, Jaehoon; Cesar, Liliana

    2009-01-01

    Purpose: Angiographic contrast that is routinely injected into arteries is used not only to evaluate arterial geometry but also in many cases to assess perfusion. The authors conducted two experiments to examine the dispersion of angiographic contrast injected antegradely into an artery under conditions similar to those found in selective (carotid artery) or superselective (circle of Willis) angiography in order to determine the distance from the catheter tip at which the contrast can be considered fully mixed with the blood. A third experiment investigated whether the contrast once mixed with blood will separate from the mixture under the gravitational field due to a density mismatch. Methods: Experiment I—Under high-speed angiographic acquisition, a bolus of contrast was injected through a catheter along the flow direction of a blood analog fluid flowing through a straight, long, cylindrical tube. The variation in grayscale intensity along the length of the tube was acquired and modeled as the step response to a second-order system. The distance from the catheter tip at which the contrast mixes with the working fluid, the mixing length, was determined as the length along the tube after which the step response settles to within 3% of the steady state value. Experiment II—A bolus of angiographic contrast was injected at rates varying from 0.1 to 1 cc∕s through three different catheter sizes in the left common carotid artery of three rabbits. The average cross-sectional grayscale intensity over one cardiac cycle was calculated at four locations along the artery: Immediately distal to the catheter tip, at location of maximum grayscale intensity, and at 10 and 20 arterial diameters from the catheter tip. The status of mixing within 10 arterial diameters was assessed by differences between the grayscale value at this location and that at the maximum and 20 arterial diameter location. Experiment III—Angiographic contrast was premixed by agitation in three

  11. AN ANALYSIS OF OPERATING PHYSICIAN AND PATIENT RADIATION EXPOSURE DURING RADIAL CORONARY ANGIOPLASTIES.

    PubMed

    Tarighatnia, Ali; Mesbahi, Asghar; Alian, Amir Hossein Mohammad; Koleini, Evin; Nader, Nader

    2018-03-23

    The objective of this study was to evaluate radiation exposure levels in conjunction with operator dose implemented, patient vascular characteristics, and other technical angiographic parameters. In total, 756 radial coronary angioplasties were evaluated in a major metropolitan general hospital in Tabriz, Iran. The classification of coronary lesions was based on the ACC/AHA system. One interventional cardiologist performed all of the procedures using a single angiography unit. The mean kerma-area product and mean cumulative dose for all cases was 5081 μGy m2 and 814.44 mGy, respectively. Average times of 26.16 and 9.1 min were recorded for the overall procedure and fluoroscopy, respectively. A strong correlation was demonstrated between types of lesions, number of stents and vessels treated in relation to physician radiation exposure. It was determined that operator radiation exposure levels for percutaneous coronary interventions lesions (complex) were higher than that of simple and moderate lesions. In addition, operator radiation exposure levels increased with the treatment of more coronary vessels and implementation of additional stents.

  12. The side-to-side fashion for individual distal coronary anastomosis using venous conduit.

    PubMed

    Kato, Takayoshi; Tsunekawa, Tomohiro; Motoji, Yusuke; Hirakawa, Akihiro; Okawa, Yasuhide; Tomita, Shinji

    2017-04-01

    Regarding to coronary artery bypass grafting (CABG), the end-to-side anastomosis (ESA) has been performed as a gold standard. Recently, the effectiveness of the distal side-to-side anastomosis (SSA) in CABG using internal mammary artery has been reported. The benefit of SSA comparing to ESA also has been disclosed by computing simulation. However, use of SSA by venous conduit for individual CABG has not been reported. In this study, we investigated feasibility of SSA. From January 2013 to October 2014, we conducted 114 CABGs. There were 92 venous distal anastomoses without sequential anastomotic site (61 SSA and 31 ESA). The anastomosis was evaluated before discharge and at 1 year after the procedure by angiography or multi-detector row computed tomographic coronary angiography. The median values for time to anastomosis were 13 min in the two group (p = 0.89). There was no revision of anastomosis in both groups. Additional stitches for hemostasis were required significantly less in SSA than ESA (18.0 vs 45.2 %, respectively, p < 0.05). Early angiographic patency; 96.6 % for SSA vs 93.5 % for ESA (p = 0.50), and percentage of good anastomotic figure; 91.2 % for SSA vs 87.1 % for ESA (p = 0.54) were similar in both groups. The angiographic patency at 1 year were 92.9 % for SSA and 81.0 % for ESA (p = 0.16). There was no predictive factor for early and late graft failure. Our study showed feasibility of SSA using venous conduit in individual CABG based on early and mid-term angiographic results. This anastomotic fashion is easy to perform and maybe beneficial in blood flow pattern.

  13. The Incidence and the Risk Factors of Silent Embolic Cerebral Infarction After Coronary Angiography and Percutaneous Coronary Interventions.

    PubMed

    Deveci, Onur Sinan; Celik, Aziz Inan; Ikikardes, Firat; Ozmen, Caglar; Caglıyan, Caglar Emre; Deniz, Ali; Bicakci, Kenan; Bicakci, Sebnem; Evlice, Ahmet; Demir, Turgay; Kanadasi, Mehmet; Demir, Mesut; Demirtas, Mustafa

    2016-05-01

    Silent embolic cerebral infarction (SECI) is a major complication of coronary angiography (CAG) and percutaneous coronary intervention (PCI). Patients with stable coronary artery disease (CAD) who underwent CAG with or without PCI were recruited. Cerebral diffusion-weighted magnetic resonance imaging was performed for SECI within 24 hours. Clinical and angiographic characteristics were compared between patients with and without SECI. Silent embolic cerebral infarction occurred in 12 (12%) of the 101 patients. Age, total cholesterol, SYNTAX score (SS), and coronary artery bypass history were greater in the SECI(+) group (65 ± 10 vs 58 ± 11 years,P= .037; 223 ± 85 vs 173 ± 80 mg/dL,P= .048; 30.1 ± 2 vs 15 ± 3,P< .001; 4 [33.3%] vs 3 [3.3%],P= .005). The SECI was more common in the PCI group (8/24 vs 4/77,P= .01). On subanalysis, the SS was significantly higher in the SECI(+) patients in both the CAG and the PCI groups (29.3 ± 1.9 vs 15 ± 3,P< .01; 30.5 ± 1.9 vs 15.1 ± 3.2,P< .001, respectively). The risk of SECI after CAG and PCI increases with the complexity of CAD (represented by the SS). The SS is a predictor of the risk of SECI, a complication that should be considered more often after CAG. © The Author(s) 2015.

  14. Coronary angiography in Qatar: the first ten years.

    PubMed

    Chaikhouni, A; Gehani, A A; Horak, J; Hajar, H A

    1998-08-01

    Cardiac catheterization in Qatar was initiated in July 1982. In ten years, a total of 3900 procedures were performed at Hamad General Hospital. Computerized data registry has been maintained since 1982. Isolated coronary angiography was done in 2911 patients; of these, 2635 (90.5%) were men, and 276 (9.5%) were women, the average age of the patients was 47+/-9.2 years (range, twenty-five to eighty-eight). Patients' nationality was Qatari in 492 (17%), and other Arabs in 610 (21%), and 1512 (52%) were from the Asian subcontinent. Myocardial infarction was the most common indication (43%). Single-vessel disease was found in 638 (22%), two-vessel disease in 630 (22%), three-vessel disease in 950 (33%), and nonsignificant coronary artery disease in 693 (24%) patients. Morbidity related to the coronary angiography was reported in 147 (5%) patients, but there was no mortality related to the procedure. In 822 (28%) patients, the age was forty years or younger. The angiographic findings of these younger patients were compared with those of the older ones. Younger patients were usually men of Asian subcontinental origin with a recent myocardial infarction (MI). Often, they had normal coronary arteries or single-vessel disease. Patients of Asian subcontinent origin were usually young male patients with a recent MI, who receive streptokinase, and have single-vessel disease.

  15. E-selectin S128R polymorphism and severe coronary artery disease in Arabs

    PubMed Central

    Abu-Amero, Khaled K; Al-Boudari, Olayan M; Mohamed, Gamal H; Dzimiri, Nduna

    2006-01-01

    Background The E-selectin p. S128R (g. A561C) polymorphism has been associated with the presence of angiographic coronary artery disease (CAD) in some populations, but no data is currently available on its association with CAD in Arabs. Methods In the present study, we determined the potential relevance of the E-selectin S128R polymorphism for severe CAD and its associated risk factors among Arabs. We genotyped Saudi Arabs for this polymorphism by PCR, followed by restriction enzyme digestion. Results The polymorphism was determined in 556 angiographically confirmed severe CAD patients and 237 control subjects with no CAD as established angiographically (CON). Frequencies of the S/S, S/R and R/R genotypes were found as 81.1%, 16.6% and 2.3% in CAD patients and 87.8%, 11.8%, and 0.4% in CON subjects, respectively. The frequency of the mutant 128R allele was higher among CAD patients compared to CON group (11% vs. 6%; odds ratio = 1.76; 95% CI 1.14 – 2.72; p = .007), thus indicating a significant association of the 128R allele with CAD among our population. However, the stepwise logistic regression for the 128R allele and different CAD risk factors showed no significant association. Conclusion Among the Saudi population, The E-selectin p. S128R (g. A561C) polymorphism was associated with angiographic CAD in Univariate analysis, but lost its association in multivariate analysis. PMID:16756647

  16. Diagnostic value of CRP and Lp(a) in coronary heart disease.

    PubMed

    Erbağci, Ayşe Binnur; Tarakçioğlu, Mehmet; Aksoy, Mehmet; Kocabaş, Ramazan; Nacak, Muradiye; Aynacioğlu, A Sükrü; Sivrikoz, Cumhur

    2002-06-01

    Increased lipoprotein (a) [Lp(a)] concentration was reported to be an independent risk factor for coronary heart disease (CHD). Recent epidemiological studies affirmed the value of C-reactive protein (CRP) as the strongest, univariate predictor of the cardiovascular events. We decided to establish cut-off levels providing maximum diagnostic efficiency for CHD. In this study we measured CRP and Lp(a) concentrations in patients with angiographically demonstrated CHD (group A, n: 120), patients without any angiographically demonstrable lesion (group B, n: 62) and a group of healthy subjects (group C, n: 41). Data were evaluated correcting for lipid and lipoprotein concentrations, diabetes mellitus, hypertension, smoking, age, and body mass index in men and women. ROC curve based cut-off values (comparing group A versus groups B and C) and associated diagnostic performances of the assays were evaluated. Significant increases were noted in serum CRP concentrations in men and women, in groups A vs. B,A vs. C, B vs. C. Lp(a) concentrations were not different among groups in men but were higher in group A vs. B and C in women. Optimal cut-off levels for CRP in women and men were found as 2.1 and 3.0 mg/l with the diagnostic values of 0.792 and 0.770, respectively. For Lp(a) optimal cut-off levels were found as 22.6 and 9.8 mg/dl with the diagnostic values of 0.612 and 0.596 in women and men, respectively. The CRP level is quite efficient for separation of patients from controls. Therefore keeping in mind the lack of specificity, the CRP level may be a useful tool in the diagnosis of coronary heart disease. However, the Lp(a) level is not efficient enough to support the use of Lp(a) measurement for management of coronary heart disease.

  17. Urinary Bisphenol A Concentration and Angiography-Defined Coronary Artery Stenosis

    PubMed Central

    Melzer, David; Gates, Phil; Osborn, Nicholas J.; Henley, William E.; Cipelli, Ricardo; Young, Anita; Money, Cathryn; McCormack, Paul; Schofield, Peter; Mosedale, David; Grainger, David; Galloway, Tamara S.

    2012-01-01

    Background Bisphenol A is widely used in food and drinks packaging. There is evidence of associations between raised urinary bisphenol A (uBPA) and increased incidence of reported cardiovascular diagnoses. Methodology/Principal Findings To estimate associations between BPA exposure and angiographically graded coronary atherosclerosis. 591 patients participating in The Metabonomics and Genomics in Coronary Artery Disease (MaGiCAD) study in Cambridgeshire UK, comparing urinary BPA (uBPA) with grades of severity of coronary artery disease (CAD) on angiography. Linear models were adjusted for BMI, occupational social class and diabetes status. Severe (one to three vessel) CAD was present in 385 patients, 86 had intermediate disease (n = 86) and 120 had normal coronary arteries. The (unadjusted) median uBPA concentration was 1.28 ng/mL with normal coronary arteries, and 1.53 ng/mL with severe CAD. Compared to those with normal coronary arteries, uBPA concentration was significantly higher in those with severe CAD (OR per uBPA SD = 5.96 ng/ml OR = 1.43, CI 1.03 to 1.98, p = 0.033), and near significant for intermediate disease (OR = 1.69, CI 0.98 to 2.94, p = 0.061). There was no significant uBPA difference between patients with severe CAD (needing surgery) and the remaining groups combined. Conclusions/Significance BPA exposure was higher in those with severe coronary artery stenoses compared to those with no vessel disease. Larger studies are needed to estimate true dose response relationships. The mechanisms underlying the association remain to be established. PMID:22916252

  18. Bioabsorbable coronary stents--are these the next big thing in coronary angioplasty?

    PubMed

    Balla, Sudarshan; Aggarwal, Kul; Nistala, Ravi

    2010-06-01

    The role of percutaneous coronary intervention (PCI) in the treatment of coronary artery disease has grown at an astronomical pace. Drug eluting stents (DES) offer advantages over bare metal stents (BMS) such as reduction in early in-stent restenosis rates. However, they have disadvantages like from increased late stent thrombosis when compared with BMS. Furthermore, recent data suggest endothelial dysfunction in the DES stented segments of the arteries. Currently, bioabsorbable stents are under development to avert the complications of DES such as stent thrombosis via degradation of the stent over time. The hypothetical advantage of leaving behind a natural vessel and restoring vasoreactivity may be the almost normal physiology which can be achieved after an intervention with a stent. The ABSORB and the PROGRESS AMS are two of the recent clinical trials that have looked at the outcomes of using bioabsorbable stents. So far, data from these and other studies has yielded mixed results in terms of angiographic and clinical outcomes. Newer stents such as REVA and WHISPER are presently being tested in preclinical and clinical trials. The landscape for bioabsorbable stents is constantly evolving through continued improvisation on existing technology and emergence of new technology. Large scale randomized trials are still needed with adequate long term follow-up for safety and benefits to have mainstream application in coronary artery disease, bioabsorbable stents are a promising innovation in the field of PCI. We review some of the patents and the data that is emerging on bioabsorbable stents in addition to currently ongoing clinical trials.

  19. Successful percutaneous coronary intervention significantly improves coronary sinus blood flow as assessed by transthoracic echocardiography.

    PubMed

    Lyubarova, Radmila; Boden, William E; Fein, Steven A; Schulman-Marcus, Joshua; Torosoff, Mikhail

    2018-06-01

    Transthoracic echocardiography (TTE) has been used to assess coronary sinus blood flow (CSBF), which reflects total coronary arterial blood flow. Successful angioplasty is expected to improve coronary arterial blood flow. Changes in CSBF after percutaneous coronary intervention (PCI), as assessed by TTE, have not been systematically evaluated. TTE can be utilized to reflect increased CSBF after a successful, clinically indicated PCI. The study cohort included 31 patients (18 females, 62 ± 11 years old) referred for diagnostic cardiac catheterization for suspected coronary artery disease and possible PCI, when clinically indicated. All performed PCIs were successful, with good angiographic outcome. CSBF per cardiac cycle (mL/beat) was measured using transthoracic two-dimensional and Doppler flow imaging as the product of coronary sinus (CS) area and CS flow time-velocity integral. CSBF per minute (mL/min) was calculated as the product of heart rate and CSBF per cardiac cycle. In each patient, CSBF was assessed prospectively, before and after cardiac catheterization with and without clinically indicated PCI. Within- and between-group differences in CSBF before and after PCI were assessed using repeated measures analysis of variance. Technically adequate CSBF measurements were obtained in 24 patients (77%). In patients who did not undergo PCI, there was no significant change in CSBF (278.1 ± 344.1 versus 342.7 ± 248.5, p = 0.36). By contrast, among patients who underwent PCI, CSBF increased significantly (254.3 ± 194.7 versus 618.3 ± 358.5 mL/min, p < 0.01, p-interaction = 0.03). Other hemodynamic and echocardiographic parameters did not change significantly before and after cardiac catheterization in either treatment group. Transthoracic echocardiographic assessment can be employed to document CSBF changes after angioplasty. Future studies are needed to explore the clinical utility of this noninvasive metric.

  20. The clinical evaluation of the CADence device in the acoustic detection of coronary artery disease.

    PubMed

    Thomas, Joseph L; Ridner, Michael; Cole, Jason H; Chambers, Jeffrey W; Bokhari, Sabahat; Yannopoulos, Demetris; Kern, Morton; Wilson, Robert F; Budoff, Matthew J

    2018-06-23

    The noninvasive detection of turbulent coronary flow may enable diagnosis of significant coronary artery disease (CAD) using novel sensor and analytic technology. Eligible patients (n = 1013) with chest pain and CAD risk factors undergoing nuclear stress testing were studied using the CADence (AUM Cardiovascular Inc., Northfield MN) acoustic detection (AD) system. The trial was designed to demonstrate non-inferiority of AD for diagnostic accuracy in detecting significant CAD as compared to an objective performance criteria (sensitivity 83% and specificity 80%, with 15% non-inferiority margins) for nuclear stress testing. AD analysis was blinded to clinical, core lab-adjudicated angiographic, and nuclear data. The presence of significant CAD was determined by computed tomographic (CCTA) or invasive angiography. A total of 1013 subjects without prior coronary revascularization or Q-wave myocardial infarction were enrolled. Primary analysis was performed on subjects with complete angiographic and AD data (n = 763) including 111 subjects (15%) with severe CAD based on CCTA (n = 34) and invasive angiography (n = 77). The sensitivity and specificity of AD were 78% (p = 0.012 for non-inferiority) and 35% (p < 0.001 for failure to demonstrate non-inferiority), respectively. AD results had a high 91% negative predictive value for the presence of significant CAD. AD testing failed to demonstrate non-inferior diagnostic accuracy as compared to the historical performance of a nuclear stress OPC due to low specificity. AD sensitivity was non-inferior in detecting significant CAD with a high negative predictive value supporting a potential value in excluding CAD.

  1. Excimer laser coronary angioplasty: relative risk analysis of clinical results

    NASA Astrophysics Data System (ADS)

    Bittl, John A.

    1992-08-01

    Reports of successful use of excimer laser coronary angioplasty for complex coronary artery disease abound, yet firm indications for its use have not been defined. We attempted to treat 858 coronary stenoses in 764 consecutive patients (mean age 61 years; range 32 - 91 years; 75% men; 76% with Class III or IV angina) with excimer laser angioplasty at 308 nm. Successful treatment was achieved in 86% of patients, as indicated by angiographic features, such as lesions at a vessel bifurcation (odds ratio, OR equals 0.46; 95% confidence interval 0.23, 0.88; P equals 0.017;) or in a tortuous segment (OR equals 0.54; 95% CI equals 0.34, 0.88; P equals 0.041), have decreased likelihood of clinical success. On the other hand, ostial stenoses (OR equals 1.06; 95% CI equals 0.44, 2.56, P equals 0.903) and saphenous vein graft lesions (OR equals 2.17; 95% CI equals 0.98, 4.82; P equals 0.051) have acceptable success rates. Diffuse disease (> 20 mm), total occlusions and calcified lesions were treated as successfully as all other lesion types. Successful treatment with excimer laser coronary angioplasty was also achieved in almost all patients (15/16) who had a prior unsuccessful attempt at balloon angioplasty in the lesion was crossed with a guidewire yet resists either balloon catheter passage or full dilatation. Follow-up angiography was obtained in 70% of eligible patients. Angiographic restenosis, defined by > 50% stenosis, was seen in 60% of patients. Relative risk analysis showed an increased risk of restenosis when adjunctive balloon angioplasty was not used (OR equals 1.68; 95% CI equals 1.02, 2.28; P equals 0.039). Other variables known to affect the outcome of balloon angioplasty, such as lesion length or stenosis in degenerated saphenous vein bypass graft, did not influence the

  2. Gender-Based Differences in Outcomes After Orbital Atherectomy for the Treatment of De Novo Severely Calcified Coronary Lesions.

    PubMed

    Lee, Michael S; Shlofmitz, Evan; Mansourian, Pejman; Sethi, Sanjum; Shlofmitz, Richard A

    2016-11-01

    We evaluated the relationship between gender and angiographic and clinical outcomes in patients with severely calcified lesions who underwent orbital atherectomy. Female gender is associated with increased risk of adverse clinical events after percutaneous coronary intervention (PCI). Severe coronary artery calcification increases the complexity of PCI and increases the risk of adverse cardiac events. Orbital atherectomy is effective in plaque modification, which facilitates stent delivery and expansion. Whether gender differences exist after orbital atherectomy is unclear. Our analysis retrospectively analyzed 458 consecutive real-world patients (314 males and 144 females) from three centers who underwent orbital atherectomy. The primary endpoint was the major adverse cardiac and cerebrovascular event (MACCE) rate, defined as the composite of death, myocardial infarction (MI), target-vessel revascularization (TVR), and stroke, at 30 days. The primary endpoint of MACCE was low and similar in females and males (0.7% vs 2.9%; P=.14). The individual endpoints of death (0.7% vs 1.6%; P=.43), MI (0.7% vs 1.3%; P=.58), TVR (0% vs 0%; P>.99), and stroke (0% vs 0.3%; P=.50) were low in both groups and did not differ. Angiographic complications were low: perforation (0.8% vs 0.7%; P>.90), dissection (0.8% vs 1.1%; P=.80), and no-reflow (0.8% vs 0.7%; P>.90). Plaque modification with orbital atherectomy was safe and provided similar angiographic and clinical outcomes between females and males. Randomized trials with longer-term follow-up are needed to support our results.

  3. Quantification of myocardial area at risk in the absence of collateral flow: the validation of angiographic scores by myocardial perfusion single-photon emission computed tomography.

    PubMed

    Rodríguez-Palomares, José F; Alonso, Albert; Martí, Gerard; Aguadé-Bruix, Santiago; González-Alujas, M T; Romero-Farina, Guillermo; Candell-Riera, Jaume; García del Blanco, Bruno; Evangelista, Artur; García-Dorado, David

    2013-02-01

    Our study aimed to compare the area at risk (AAR) determined by single-photon emission computed tomography (SPECT) with the Bypass Angioplasty Revascularization Investigation (BARI) and modified Alberta Provincial Project for Outcome Assessment in Coronary Heart Disease (APPROACH) angiographic scores in the setting of patients undergoing coronary angioplasty for either unstable angina or an STEMI. Radionuclide myocardial perfusion imaging prior to reperfusion has classically been the most widely practised technique for assessing the AAR and has been successfully used to compare the efficacy of various reperfusion strategies in patients with an ST-segment elevation myocardial infarction (STEMI). The BARI and modified APPROACH scores are angiographic methods widely used to provide a rapid estimation of the AAR; however, they have not been directly validated with myocardial perfusion single-photon emission computed tomography (SPECT). Fifty-five patients with no previous myocardial infarction who underwent coronary angioplasty for single-vessel disease (unstable angina: n = 25 or an STEMI: n = 30) with no evidence of collaterals (Rentrop Collateral Score <2) were included in a prospective study. In STEMI patients, the (99m)Tc-tetrofosmin was injected prior to opening of the occluded vessel and, in patients with unstable angina after 10-15 seconds of balloon inflation. Acquisition was performed with a dual-head gammacamera with a low-energy and high-resolution collimator. A total of 60 projections were acquired using a non-circular orbit. No attenuation or scatter correction was used. Maximal contours of hypoperfusion regions corresponding to each coronary artery occlusion were delineated over a polar map of 17 segments and compared with the estimated AAR determined by two experienced interventional cardiologists using both angiographic scores. Mean AAR percentage in SPECT was 35.0 (10.0%-56.0%). A high correlation was found between BARI and APPROACH scores (r = 0.9, P

  4. A comparison of chemoembolization endpoints using angiographic versus transcatheter intraarterial perfusion/MR imaging monitoring.

    PubMed

    Lewandowski, Robert J; Wang, Dingxin; Gehl, James; Atassi, Bassel; Ryu, Robert K; Sato, Kent; Nemcek, Albert A; Miller, Frank H; Mulcahy, Mary F; Kulik, Laura; Larson, Andrew C; Salem, Riad; Omary, Reed A

    2007-10-01

    Transcatheter arterial chemoembolization (TACE) is an established treatment for unresectable liver cancer. This study was conducted to test the hypothesis that angiographic endpoints during TACE are measurable and reproducible by comparing subjective angiographic versus objective magnetic resonance (MR) endpoints of TACE. The study included 12 consecutive patients who presented for TACE for surgically unresectable HCC or progressive hepatic metastases despite chemotherapy. All procedures were performed with a dedicated imaging system. Angiographic series before and after TACE were reviewed independently by three board-certified interventional radiologists. A subjective angiographic chemoembolization endpoint (SACE) classification scheme, modified from an established angiographic grading system in the cardiology literature, was designed to assist in reproducibly classifying angiographic endpoints. Reproducibility in SACE classification level was compared among operators, and MR imaging perfusion reduction was compared with SACE levels for each observer. Twelve patients successfully underwent 15 separate TACE sessions. SACE levels ranged from I through IV. There was moderate agreement in SACE classification (kappa = 0.46 +/- 0.12). There was no correlation between SACE level and MR perfusion reduction (r = 0.16 for one operator and 0.02 for the other two). Angiographic endpoints during TACE vary widely, have moderate reproducibility among operators, and do not correlate with functional MR imaging perfusion endpoints. Future research should aim to determine ideal angiographic and functional MR imaging endpoints for TACE according to outcome measures such as imaging response, pathologic response, and survival.

  5. Routine intraoperative completion angiography after coronary artery bypass grafting and 1-stop hybrid revascularization results from a fully integrated hybrid catheterization laboratory/operating room.

    PubMed

    Zhao, David X; Leacche, Marzia; Balaguer, Jorge M; Boudoulas, Konstantinos D; Damp, Julie A; Greelish, James P; Byrne, John G; Ahmad, Rashid M; Ball, Stephen K; Cleator, John H; Deegan, Robert J; Eagle, Susan S; Fong, Pete P; Fredi, Joseph L; Hoff, Steven J; Jennings, Henry S; McPherson, John A; Piana, Robert N; Pretorius, Mias; Robbins, Mark A; Slosky, David A; Thompson, Annemarie

    2009-01-20

    This study sought to report our experience with a routine completion angiogram after coronary artery bypass surgery (CABG) and simultaneous (1-stop) percutaneous coronary intervention (PCI) at the time of CABG performed in the hybrid catheterization laboratory/operating room. The value of a routine completion angiogram after CABG and 1-stop hybrid CABG/PCI remains unresolved. Between April 2005 and July 2007, 366 consecutive patients underwent CABG surgery, with (n = 112) or without (n = 254) concomitant 1-stop PCI (hybrid), all with completion angiography before chest closure. Among the 112 1-stop hybrid CABG/PCI patients, 67 (60%) underwent a planned hybrid procedure based on pre-operative assessment, whereas 45 (40%) underwent open-chest PCI (unplanned hybrid) based on intraoperative findings. Among the 796 CABG grafts (345 left internal mammary artery, 12 right internal mammary artery/radial, and 439 veins), 97 (12%) angiographic defects were identified. Defects were repaired with either a minor adjustment of the graft (n = 22, 2.8%), with intraoperative open-chest PCI (unplanned hybrid, n = 48, 6%) or with traditional surgical revision (n = 27, 3.4%). Hybrid patients had clinical outcomes similar to standard CABG patients. Routine completion angiography detected 12% of grafts with important angiographic defects. One-stop hybrid coronary revascularization is reasonable, safe, and feasible. Combining the tools of the catheterization laboratory and operating room greatly enhances the options available to the surgeon and cardiologist for patients with complex coronary artery disease.

  6. Orbital atherectomy for the treatment of severely calcified coronary lesions: evidence, technique, and best practices.

    PubMed

    Shlofmitz, Evan; Martinsen, Brad J; Lee, Michael; Rao, Sunil V; Généreux, Philippe; Higgins, Joe; Chambers, Jeffrey W; Kirtane, Ajay J; Brilakis, Emmanouil S; Kandzari, David E; Sharma, Samin K; Shlofmitz, Richard

    2017-11-01

    The presence of severe coronary artery calcification is associated with higher rates of angiographic complications during percutaneous coronary intervention (PCI), as well as higher major adverse cardiac events compared with non-calcified lesions. Incorporating orbital atherectomy (OAS) for effective preparation of severely calcified lesions can help maximize the benefits of PCI by attaining maximal luminal gain (or stent expansion) and improve long-term outcomes (by reducing need for revascularization). Areas covered: In this manuscript, the prevalence, risk factors, and impact of coronary artery calcification on PCI are reviewed. Based on current data and experience, the authors review orbital atherectomy technique and best practices to optimize lesion preparation. Expert Commentary: The coronary OAS is the only device approved for use in the U.S. as a treatment for de novo, severely calcified coronary lesions to facilitate stent delivery. Advantages of the device include its ease of use and a mechanism of action that treats bi-directionally, allowing for continuous blood flow during treatment, minimizing heat damage, slow flow, and subsequent need for revascularization. The OAS technique tips reviewed in this article will help inform interventional cardiologists treating patients with severely calcified lesions.

  7. Characterizing the microcirculation of atopic dermatitis using angiographic optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Byers, R. A.; Maiti, R.; Danby, S. G.; Pang, E. J.; Mitchell, B.; Carré, M. J.; Lewis, R.; Cork, M. J.; Matcher, S. J.

    2017-02-01

    Background and Aim: With inflammatory skin conditions such as atopic dermatitis (AD), epidermal thickness is mediated by both pathological hyperplasia and atrophy such as that resulting from corticosteroid treatment. Such changes are likely to influence the depth and shape of the underlying microcirculation. Optical coherence tomography (OCT) provides a non-invasive view into the tissue, however structural measures of epidermal thickness are made challenging due to the lack of a delineated dermal-epidermal junction in AD patients. Instead, angiographic extensions to OCT may allow for direct measurement of vascular depth, potentially presenting a more robust method of estimating the degree of epidermal thickening. Methods and results: To investigate microcirculatory changes within AD patients, volumes of angiographic OCT data were collected from 5 healthy volunteers and compared to that of 5 AD patients. Test sites included the cubital and popliteal fossa, which are commonly affected by AD. Measurements of the capillary loop and superficial arteriolar plexus (SAP) depth were acquired and used to estimate the lower and upper bounds of the undulating basement membrane of the dermal-epidermal junction. Furthermore, quantitative parameters such as vessel density and diameter were derived from each dataset and compared between groups. Capillary loop depth increased slightly for AD patients at the poplitial fossa and SAP was found to be measurably deeper in AD patients at both sites, likely due to localized epidermal hyperplasia.

  8. Association between circulating microRNA-208a and severity of coronary heart disease.

    PubMed

    Zhang, Yao; Li, Hai-Hong; Yang, Rui; Yang, Bai-Jing; Gao, Zhao-Yu

    2017-09-01

    Circulating microRNA (miR)-208a is specifically expressed in the heart muscle, which is involved in the regulation of myosin during cardiac development. Previous studies reported that cardiac-specific miR-208a level is significantly higher in plasma of coronary heart disease (CHD) patients. However, whether it correlates with severity of CHD, has never been elucidated before. The aim of this study was to explore the association between miR-208a and the presence and severity of CHD. Samples were collected from 290 CHD patients and 110 subjects with angiographic exclusion of CHD. Circulating miRNA-208a expression was detected using quantitative real-time PCR. The Gensini score was used to evaluate the severity of coronary stenotic lesions. Expression of miRNA-208a was identified on the basis of the quartiles of the Gensini score, and association between the miRNA-208a levels and CHD was analyzed. Diagnostic potential of miR-208a of CHD was performed by ROC analysis. CHD patients had higher miRNA-208a expression (1.61, 0.45-3.86 vs. 0.66, 0.11-1.42, p < .001), and the biomarker level significantly increased following an increasing the Gensini score (p < .001). Gensini score was significantly associated with miRNA-208a expression (r = 0.8525, p < .001). The optimal cut-off value of the relative level of miR-208a was with a specificity of 93.6% and a sensitivity of 75.5%. The AUC of miR-208a was 0.919 (95% CI, 0.893-0.945; p < .001). These preliminary results suggest that the expression of miR-208a may be associated with atherogenesis. The level of circulating miR-208a in predicting the severity of coronary atherosclerosis may have a relatively certain value.

  9. Re-examining minimal luminal diameter relocation and quantitative coronary angiography--intravascular ultrasound correlations in stented saphenous vein grafts: methodological insights from the randomised RRISC trial.

    PubMed

    Semeraro, Oscar; Agostoni, Pierfrancesco; Verheye, Stefan; Van Langenhove, Glenn; Van den Heuvel, Paul; Convens, Carl; Van den Branden, Frank; Bruining, Nico; Vermeersch, Paul

    2009-03-01

    Angiographic parameters (such as late luminal loss) are common endpoints in drug-eluting stent trials, but their correlation with the neointimal process and their reliability in predicting restenosis are debated. Using quantitative coronary angiography (QCA) data (49 bare metal stent and 44 sirolimus-eluting stent lesions) and intravascular ultrasound (IVUS) data (39 bare metal stent and 34 sirolimus-eluting stent lesions) from the randomised Reduction of Restenosis In Saphenous vein grafts with Cypher stent (RRISC) trial, we analysed the "relocation phenomenon" of QCA-based in-stent minimal luminal diameter (MLD) between post-procedure and follow-up and we correlated QCA-based and IVUS-based restenotic parameters in stented saphenous vein grafts. We expected the presence of MLD relocation for low late loss values, as MLD can "migrate" along the stent if minimal re-narrowing occurs, while we anticipated follow-up MLD to be located close to post-procedural MLD position for higher late loss. QCA-based MLD relocation occurred frequently: the site of MLD shifted from post-procedure to follow-up an "absolute" distance of 5.8 mm [2.5-10.2] and a "relative" value of 29% [10-46]. MLD relocation failed to correlate with in-stent late loss (rho = 0.14 for "absolute" MLD relocation [p = 0.17], and rho=0.03 for "relative" relocation [p = 0.811). Follow-up QCA-based and IVUS-based MLD values well correlated in the overall population (rho = 0.76, p < 0.001), but QCA underestimated MLD on average 0.55 +/- 0.49 mm, and this was mainly evident for lower MLD values. Conversely, the location of QCA-based MLD failed to correlate with the location of IVUS-based MLD (rho = 0.01 for "absolute" values--in mm [p = 0.911, rho = 0.19 for "relative" values--in % [p = 0.111). Overall, the ability of late loss to "predict" IVUS parameters of restenosis (maximum neointimal hyperplasia diameter, neointimal hyperplasia index and maximum neointimal hyperplasia area) was moderate (rho between 0

  10. The role of urotensin II and atherosclerotic risk factors in patients with slow coronary flow

    PubMed Central

    Şatıroğlu, Ömer; Emre Durakoğlugil, Murtaza; Çetin, Mustafa; Çiçek, Yüksel; Erdoğan, Turan; Duman, Hakan

    2016-01-01

    Background Slow coronary flow (SCF) is an angiographic finding characterized with delayed opacification of epicardial coronary arteries without obstructive coronary disease. Urotensin II (UII) is an important vascular peptide, which has an important role in hypertension, coronary artery disease, and vascular remodeling in addition to potent vasoconstrictor effect. Objectives We investigated UII levels, hypertension, and other atherosclerotic risk factors in patients with SCF, a variety of coronary artery disease. Methods We enrolled 14 patients with SCF and 29 subjects with normal coronary arteries without SCF. We compared the UII levels and the atherosclerotic risk factors between patients with SCF and control subjects with normal coronary flow. Results UII concentrations were significantly higher in patients with SCF compared to controls (711.0 ± 19.4 vs. 701.5 ± 27.2 ng/mL, p = 0.006). We detected a positive correlation between SCF and age (r = 0.476, p = 0.001), BMI (r = 0.404, p = .002), UII concentrations (r = 0.422, p = 0.006), and hypertension (r = 0.594, p = 0.001). Conclusion We identified increased UII levels in patients with SCF. We think that UII concentrations may be informative on SCF pathogenesis due to relationship with inflammation, atherosclerosis, and vascular remodeling. PMID:28180005

  11. Serum neutrophil gelatinase-associated lipocalin levels are correlated with the complexity and the severity of atherosclerosis in acute coronary syndrome

    PubMed Central

    Soylu, Korhan; Aksan, Gökhan; Nar, Gökay; Özdemir, Metin; Gülel, Okan; İnci, Sinan; Aksakal, Aytekin; İdil Soylu, Ayşegül; Yılmaz, Özcan

    2015-01-01

    Objective: Neutrophil gelatinase-associated lipocalin (NGAL) is a novel inflammatory marker that is released from neutrophils. In this study, we evaluated the correlation between serum NGAL level and clinical and angiographic risk scores in patients diagnosed with non-ST elevation acute coronary syndrome (NSTE-ACS). Methods: Forty-seven random NSTE-ACS patients and 45 patients with normal coronary arteries (NCA) who underwent coronary angiography were enrolled in the study. GRACE risk score and SYNTAX and Gensini risk scores were used, respectively, for the purpose of clinical risk assessment and angiographic risk scoring. Serum NGAL level was measured via ELISA in peripheral blood samples obtained from the patients at the time of admission. Results: Serum NGAL level was significantly higher in the NSTE-ACS group compared to the control group (112.3±49.6 ng/mL vs. 58.1±24.3 ng/mL, p<0.001). There was a significant positive correlation between serum NGAL levels and the GRACE (r=0.533 and p<0.001), SYNTAX (r=0.395 and p=0.006), and Gensini risk scores (r=0.575 and p<0.001). The intermediate-high SYNTAX (>22) group had statistically significantly higher serum NGAL levels compared to the low SYNTAX (≤22) group (143±29.5 ng/mL vs. 98.7±43.2 ng/mL, p=0.001). Conclusion: NGAL level was positively correlated with lesion complexity and severity of coronary artery disease in patients with NSTE-ACS. Serum NGAL levels on admission are associated with increased burden of atherosclerosis in patients with NSTE-ACS. PMID:25430410

  12. Coronary artery screening by electron beam computed tomography. Facts, controversy, and future.

    PubMed

    Wong, N D; Detrano, R C; Abrahamson, D; Tobis, J M; Gardin, J M

    1995-08-01

    Coronary calcium as detected by electron beam computed tomography always signifies at least some atherosclerosis, appears to be correlated with coronary risk factors, cardiac history, and overall angiographic severity of disease, but is inconsistently related to degree of atherosclerotic lesion stenosis in a given artery. Increasing evidence, however, suggests an association between coronary artery calcium, atherosclerosis, and coronary risk. But atherosclerosis is a very common condition, its prevalence increasing with age. No fully validated method for determining the quantity of coronary calcium is available, and we do not know whether the amount of calcium is a consistently accurate reflection of the amount of atherosclerosis or whether the amount of atherosclerosis reflects the degree of risk. Furthermore, the prognostic significance of coronary calcium in any given atherosclerotic lesion is not yet established. What is clear from cohort studies, however, is that at least three quarters of asymptomatic individuals, at least half of whom would have "positive" coronary calcium electron beam computed tomographic scans, will live for at least 10 years without cardiac problems of any kind. Investigation is needed to determine whether medical intervention may impact the clinical outcome of the rest of those identified with a positive scan but destined to suffer future clinical events. Despite lack of validation, this test has widespread appeal, both to the public as a means of being able to find out the condition of their coronary arteries "without injections or dye" and to hospitals and private medical groups who view this both as an innovation in cardiovascular diagnosis and as a potentially profitable diagnostic procedure.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Coronary intervention in anomalous origin of the right coronary artery (ARCA) from the left sinus of valsalva (LSOV): a single center experience.

    PubMed

    Uthayakumaran, Kalaichelvan; Subban, Vijayakumar; Lakshmanan, Anitha; Pakshirajan, Balaji; Solirajaram, Ramkumar; Krishnamoorthy, Jaishankar; Janakiraman, Ezhilan; Pandurangi, Ulhas M; Kalidoss, Latchumanadhas; Sankaradas, Mullasari Ajit

    2014-01-01

    To assess the technical challenges in percutaneous coronary intervention of Anomalous right coronary artery arising from the left sinus of valsalva. Between year 2008 and 2012, a total of 17 patients underwent PCI for an angiographically significant lesion in the right coronary artery of an anomalous origin in the LSOV. Their procedure details such as usage of catheters, radiation time, amount of contrast used were assessed. A total of 17 patients with anomalous right coronary artery underwent PCI during the above mentioned period. 8 patients had type A origin, 3 had type B origin and the remaining 6 had type C origin. Type A origin RCA were successfully cannulated in 6 patients with Judkins left 5.0 and in 2 patients using Judkins left 4.0. Extra back up (EBU) 3.5 were doing well in 2 patients of Type B origin and the remaining one patient was successfully cannulated using Judkins left 4.0. In type C origin 4 patients had successful cannulation with Amplatz Left 1.0, 1 patient with Amplatz Left 2.0 and 1 patient with Judkins left 4.0. The mean fluoroscopic time was 20.7 min and amount of contrast used was 210 ml. PCI of anomalous RCA origin from LSOV requires appropriate guide catheter selection according to the anatomy of origin for successful cannulation and to reduce the contrast usage and radiation exposure. Copyright © 2014. Published by Elsevier B.V.

  14. The management of hypercholesterolemia in patients with coronary artery disease: guidelines for primary care.

    PubMed

    Vogel, R A

    1998-01-01

    More than 10 million individuals in the United States currently have symptomatic coronary artery disease (CAD). Asymptomatic CAD is even more prevalent. CAD in the United States is responsible for approximately 1.5 million myocardial infarctions, 500,000 deaths, and a total economic burden in excess of $120 billion annually. Fortunately, CAD is preventable in many individuals. Our understanding of CAD has steadily progressed throughout the 20th century, and now several lines of evidence support the importance of cholesterol in both the genesis and management of coronary atherosclerosis. Following identification of the presence of cholesterol in atheromas, Anitschkov early this century demonstrated that atherosclerotic lesions can be induced in susceptible animals by high-saturated-fat and cholesterol diets. These lesions regressed when low-fat and cholesterol diets were resumed. In the 1970s and 1980s, findings from the landmark Framingham Heart, Seven Countries, and Multiple Risk Factor Intervention Trial studies firmly established that hypercholesterolemia was a major risk factor for cardiovascular morbidity and mortality. During the 1980s and 1990s, 21 of 22 angiographic trials demonstrated reduced progression of coronary and/or carotid artery disease using lifestyle, drug, and surgical means for reducing cholesterol. The later trials commonly employed hydroxymethylglutaryl coenzyme A reductase inhibitors (statins), reflecting increasing clinical use of these drugs. In 1988, the Adult Treatment Panel of the National Cholesterol Education Program (NCEP) published guidelines on testing and treating hypercholesterolemic patients, which outlined a more aggressive approach to cholesterol lowering than was currently in practice. Since 1994, five large cardiovascular event trials and a large angiographic trial have shown that aggressive cholesterol lowering reduces both cardiac morbidity and mortality, largely substantiating the NCEP guidelines. Although important

  15. Opium addiction as an independent risk factor for coronary microvascular dysfunction: A case-control study of 250 consecutive patients with slow-flow angina.

    PubMed

    Esmaeili Nadimi, Ali; Pour Amiri, Farah; Sheikh Fathollahi, Mahmood; Hassanshahi, Gholamhossien; Ahmadi, Zahra; Sayadi, Ahmad Reza

    2016-09-15

    Approximately 20% to 30% of patients who undergo coronary angiography for assessment of typical cardiac chest pain display microvascular coronary dysfunction (MCD). This study aimed to determine potential relationships between baseline clinical characteristics and likelihood of MCD diagnosis in a large group of patients with stable angina symptoms, positive exercise test and angiographic ally normal epicardial coronary arteries. This cross-sectional study included 250 Iranian with documented evidence of cardiac ischemia on exercise testing, class I or II indication for coronary angiography, and either: (1) angiographically normal coronary arteries and diagnosis of MCD with slow-flow phenomenon, or (2) normal angiogram and no evidence of MCD. All patients completed a questionnaire designed to capture key data including clinical demographics, past medical history, and social factors. Data was evaluated using single and multivariable logistic regression models to identify potential individual patient factors that might help to predict a diagnosis of MCD. 125 (11.2% of total) patients were subsequently diagnosed with MCD. 125 consecutive control subjects were selected for comparison. The mean age was similar among the two groups (52.38 vs. 53.26%, p=ns), but there was a higher proportion of men in the study group compared to control (42.4 vs. 27.2%, p=0.012). No significant relationships were observed between traditional cardiovascular risk factors (diabetes, hypertension, and dyslipidemia) or body mass index (BMI), and likelihood of MCD diagnosis. However, opium addiction was found to be an independent predictor of MCD on single and multivariable logistic regression model (OR=3.575, 95%CI: 1.418-9.016; p=0.0069). We observed a significant relationship between opium addiction and microvascular angina. This novel finding provides a potential mechanistic insight into the pathogenesis of MCD with slow-flow phenomenon. Copyright © 2016 Elsevier Ireland Ltd. All rights

  16. Diastolic coronary artery pressure-flow velocity relationships in conscious man.

    PubMed

    Dole, W P; Richards, K L; Hartley, C J; Alexander, G M; Campbell, A B; Bishop, V S

    1984-09-01

    We characterised the diastolic pressure-flow velocity relationship in the normal left coronary artery of conscious man before and after vasodilatation with angiographic contrast medium. Phasic coronary artery pressure and flow velocity were measured in ten patients during individual diastoles (0.5 to 1.0 s) using a 20 MHz catheter-tipped, pulsed Doppler transducer. All pressure-flow velocity curves were linear over the diastolic pressure range of 110 +/- 15 (SD) mmHg to 71 +/- 7 mmHg (r = 0.97 +/- 0.01). In the basal state, values for slope and extrapolated zero flow pressure intercept averaged 0.35 +/- 0.12 cm X s-1 X mmHg-1 and 51.7 +/- 8.6 mmHg, respectively. Vasodilatation resulted in a 2.5 +/- 0.5 fold increase in mean flow velocity. The diastolic pressure-flow velocity relationship obtained during peak vasodilatation compared to that during basal conditions was characterised by a steeper slope (0.80 +/- 0.48 cm X s-1 X mmHg-1, p less than 0.001) and lower extrapolated zero flow pressure intercept (37.9 +/- 9.8 mmHg, p less than 0.05). Mean right atrial pressure for the group averaged 4.4 +/- 1.7 mmHg, while left ventricular end-diastolic pressure averaged 8.7 +/- 2.8 mmHg. These observations in man are similar to data reported in the canine coronary circulation which are consistent with a vascular waterfall model of diastolic flow regulation. In this model, coronary blood flow may be regulated by changes in diastolic zero flow pressure as well as in coronary resistance.

  17. Relationship between quantitative measurement of Porphyromonas gingivalis on dental plaque with periodontal status of patients with coronary heart disease

    NASA Astrophysics Data System (ADS)

    Dwiyanti, Stephani; Soeroso, Yuniarti; Sunarto, Hari; Radi, Basuni

    2017-02-01

    Coronary heart disease is a narrowing of coronary artery due to plaque build-up. [1] Chronic periodontitis increases risk of cardiovascular disease. P.gingivalis is linked to both diseases. Objective: to analyse quantitative difference of P.gingivalis on dental plaque and its relationship with periodontal status of CHD patient and control. Methods: Periodontal status of 66 CHD patient and 40 control was checked. Subgingival plaque was isolated and P.gingivalis was measured using real-time PCR. Result: P.gingivalis of CHD patient differs from control. P.gingivalis is linked to pocket depth of CHD patient. Conclusion: P.gingivalis count of CHD patient is higher than control. P.gingivalis count is not linked to any periodontal status, except for pocket depth of CHD patient.

  18. Patient-specific 3D printing simulation to guide complex coronary intervention.

    PubMed

    Oliveira-Santos, Manuel; Oliveira Santos, Eduardo; Marinho, Ana Vera; Leite, Luís; Guardado, Jorge; Matos, Vítor; Pego, Guilherme Mariano; Marques, João Silva

    2018-05-07

    The field of three-dimensional printing applied to patient-specific simulation is evolving as a tool to enhance intervention results. We report the first case of a fully simulated percutaneous coronary intervention in a three-dimensional patient-specific model to guide treatment. An 85-year-old female presented with symptomatic in-stent restenosis in the ostial circumflex and was scheduled for percutaneous coronary intervention. Considering the complexity of the anatomy, patient setting and intervention technique, we elected to replicate the coronary anatomy using a three-dimensional model. In this way, we simulated the intervention procedure beforehand in the catheterization laboratory using standard materials. The procedure was guided by optical coherence tomography, with pre-dilatation of the lesion, implantation of a single drug-eluting stent in the ostial circumflex and kissing balloon inflation to the left anterior descending artery and circumflex. Procedural steps were replicated in the real patient's treatment, with remarkable parallelism in angiographic outcome and luminal gain at intracoronary imaging. In this proof-of-concept report, we show that patient-specific simulation is feasible to guide the treatment strategy of complex coronary artery disease. It enables the surgical team to plan and practice the procedure beforehand, and possibly predict complications and gain confidence. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. The Investigation of Serum Vaspin Level in Atherosclerotic Coronary Artery Disease

    PubMed Central

    Kobat, Mehmet Ali; Celik, Ahmet; Balin, Mehmet; Altas, Yakup; Baydas, Adil; Bulut, Musa; Aydin, Suleyman; Dagli, Necati; Yavuzkir, Mustafa Ferzeyn; Ilhan, Selcuk

    2012-01-01

    Background It was speculated that fatty tissue originated adipocytokines may play role in pathogenesis of atherosclerosis. These adipocytokines may alter vascular homeostasis by effecting endothelial cells, arterial smooth muscle cells and macrophages. Vaspin is a newly described member of adipocytokines family. We aimed to investigate whether plasma vaspin level has any predictive value in coronary artery disease (CAD). Methods Forty patients who have at least single vessel ≥ 70 % stenosis demostrated angiographically and 40 subjects with normal coronary anatomy were included to the study. The vaspin levels were measured from serum that is obtained by centrifigation of blood and stored at -20 oC by ELISA method. The length, weight and body mass index of patients were measured. Biochemical parameters including total cholesterol, low density lipoprotein, high density lipoprotein, creatinine, sodium, potassium, hemoglobine, uric acid and fasting glucose were also measured. Results Biochemical markers levels were similar in both groups. Serum vaspin levels were significantly lower in CAD patients than control group (respectively; 256 ± 219 pg/ml vs. 472 ( 564 pg/ml, P < 0.02). Beside this serum vaspin level was lower in control group with high systolic blood pressure. Conclusion Serum vaspin levels were found significantly lower in patients with CAD than age-matched subjects with normal coronary anatomy. Vaspin may be used as a predictor of CAD. Keywords Coronary artery disease; Vaspin; Adipokine PMID:22505983

  20. The investigation of serum vaspin level in atherosclerotic coronary artery disease.

    PubMed

    Kobat, Mehmet Ali; Celik, Ahmet; Balin, Mehmet; Altas, Yakup; Baydas, Adil; Bulut, Musa; Aydin, Suleyman; Dagli, Necati; Yavuzkir, Mustafa Ferzeyn; Ilhan, Selcuk

    2012-04-01

    It was speculated that fatty tissue originated adipocytokines may play role in pathogenesis of atherosclerosis. These adipocytokines may alter vascular homeostasis by effecting endothelial cells, arterial smooth muscle cells and macrophages. Vaspin is a newly described member of adipocytokines family. We aimed to investigate whether plasma vaspin level has any predictive value in coronary artery disease (CAD). Forty patients who have at least single vessel ≥ 70 % stenosis demostrated angiographically and 40 subjects with normal coronary anatomy were included to the study. The vaspin levels were measured from serum that is obtained by centrifigation of blood and stored at -20 (o)C by ELISA method. The length, weight and body mass index of patients were measured. Biochemical parameters including total cholesterol, low density lipoprotein, high density lipoprotein, creatinine, sodium, potassium, hemoglobine, uric acid and fasting glucose were also measured. Biochemical markers levels were similar in both groups. Serum vaspin levels were significantly lower in CAD patients than control group (respectively; 256 ± 219 pg/ml vs. 472 ( 564 pg/ml, P < 0.02). Beside this serum vaspin level was lower in control group with high systolic blood pressure. Serum vaspin levels were found significantly lower in patients with CAD than age-matched subjects with normal coronary anatomy. Vaspin may be used as a predictor of CAD. Coronary artery disease; Vaspin; Adipokine.

  1. Multi-functional angiographic OFDI using frequency-multiplexed dual-beam illumination

    PubMed Central

    Kim, SunHee; Park, Taejin; Jang, Sun-Joo; Nam, Ahhyun S.; Vakoc, Benjamin J.; Oh, Wang-Yuhl

    2015-01-01

    Detection of blood flow inside the tissue sample can be achieved by measuring the local change of complex signal over time in angiographic optical coherence tomography (OCT). In conventional angiographic OCT, the transverse displacement of the imaging beam during the time interval between a pair of OCT signal measurements must be significantly reduced to minimize the noise due to the beam scanning-induced phase decorrelation at the expense of the imaging speed. Recent introduction of dual-beam scan method either using polarization encoding or two identical imaging systems in spectral-domain (SD) OCT scheme shows potential for high-sensitivity vasculature imaging without suffering from spurious phase noise caused by the beam scanning-induced spatial decorrelation. In this paper, we present multi-functional angiographic optical frequency domain imaging (OFDI) using frequency-multiplexed dual-beam illumination. This frequency multiplexing scheme, utilizing unique features of OFDI, provides spatially separated dual imaging beams occupying distinct electrical frequency bands that can be demultiplexed in the frequency domain processing. We demonstrate the 3D multi-functional imaging of the normal mouse skin in the dorsal skin fold chamber visualizing distinct layer structures from the intensity imaging, information about mechanical integrity from the polarization-sensitive imaging, and depth-resolved microvasculature from the angiographic imaging that are simultaneously acquired and automatically co-registered. PMID:25968731

  2. Same-day discharge after coronary stenting and femoral artery device closure: A randomized study in stable and low-risk acute coronary syndrome patients.

    PubMed

    Clavijo, Leonardo C; Cortes, Guillermo A; Jolly, Aaron; Tun, Han; Mehra, Anilkumar; Gaglia, Michael A; Shavelle, David; Matthews, Ray V

    2016-01-01

    To compare same-day (SD) vs. delayed hospital discharge (DD) after single and multivessel coronary stenting facilitated by femoral closure device in patients with stable angina and low-risk acute coronary syndrome (ACS). University of Southern California patients were screened and coronary stenting was performed in 2480 patients. Four hundred ninety-three patients met screening criteria and consented. Four hours after percutaneous coronary intervention, 100 were randomized to SD (n=50) or DD (n=50). Patients were followed for one year; outcomes-, patient satisfaction-, and cost analyses were performed. Groups were well distributed, with similar baseline demographic and angiographic characteristics. Mean age was 58.1±8.8years and 86% were male. Non-ST-elevation myocardial infarction and unstable angina were the clinical presentations in 30% and 44% of the SD and DD groups, respectively (p=0.2). Multivessel stenting was performed in 36% and 30% of SD and DD groups, respectively (p=0.14). At one year, two patients from each group (4%) required unplanned revascularization and one patient in the SD group had a gastrointestinal bleed that required a blood transfusion. Six SD and four DD patients required repeat hospitalization (p=0.74). There were no femoral artery vascular complications in either group. Patient satisfaction scores were equivalent. SD discharge was associated with $1200 savings per patient. SD discharge after uncomplicated single and multivessel coronary stenting of patients with stable, low-risk ACS, via the femoral approach facilitated by a closure device, is associated with similar clinical outcomes, patient satisfaction, and cost savings compared to overnight (DD) hospital stay. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Pooled diagnostic accuracy of resting distal to aortic coronary pressure referenced to fractional flow reserve: The importance of resting coronary physiology.

    PubMed

    Maini, Rohit; Moscona, John; Sidhu, Gursukhman; Katigbak, Paul; Fernandez, Camilo; Irimpen, Anand; Mogabgab, Owen; Ward, Charisse; Samson, Rohan; LeJemtel, Thierry

    2018-04-29

    Both resting and hyperemic physiologic methods to guide coronary revascularization improve cardiovascular outcomes compared with angiographic guidance alone. Fractional flow reserve (FFR) remains underutilized due to concerns regarding hyperemia, prompting study of resting distal to aortic coronary pressure (Pd/Pa). Pd/Pa is a vasodilator-free resting index unlike FFR. While Pd/Pa is similar to another resting index, instantaneous wave-free ratio (iFR), it is a whole-cycle measurement not limited to the wave-free diastolic period. Pd/Pa is not validated clinically although multiple accuracy studies have been performed. Our meta-analysis examines the overall diagnostic accuracy of Pd/Pa referenced to FFR, the accepted invasive standard of ischemia. We searched PubMed, EMBASE, Central, ProQuest, and Web of Science databases for full text articles published through August 9, 2017 addressing the diagnostic accuracy of Pd/Pa referenced to FFR < 0.80. The following keywords were used: "distal coronary artery pressure" OR "Pd/Pa" AND "fractional flow reserve" OR "FFR." In total, 14 studies comprising 7004 lesions were identified. Pooled diagnostic accuracy estimates of Pd/Pa versus FFR < 0.80 were: sensitivity, 0.77 (95% CI, 0.75-0.78); specificity, 0.82 (0.81-0.83); positive likelihood ratio, 4.7 (3.3-6.6); negative likelihood ratio, 0.29 (0.24-0.34); diagnostic odds ratio, 18.1 (14.4-22.6); area under the summary receiver-operating characteristic curve of 0.88; and diagnostic accuracy of 0.80 (0.76-0.83). Pd/Pa shows adequate agreement with FFR as a resting index of coronary stenosis severity without the undesired effects and cost of hyperemic agents. Pd/Pa has the potential to guide coronary revascularization with easier application and availability compared with iFR and FFR. © 2018, Wiley Periodicals, Inc.

  4. Circulating microRNAs correlated with the level of coronary artery calcification in symptomatic patients

    PubMed Central

    Liu, Wei; Ling, Shukuan; Sun, Weijia; Liu, Tong; Li, Yuheng; Zhong, Guohui; Zhao, Dingsheng; Zhang, Pengfei; Song, Jinping; Jin, Xiaoyan; Xu, Zi; Song, Hailin; Li, Qi; Liu, Shujuan; Chai, Meng; Dai, Qinyi; He, Yi; Fan, Zhanming; Zhou, Yu Jie; Li, Yingxian

    2015-01-01

    The purpose of this study was to find the circulating microRNAs (miRNAs) co-related with the severity of coronary artery calcification (CAC), and testify whether the selected miRNAs could reflect the obstructive coronary artery disease in symptomatic patients. Patients with chest pain and moderated risk for coronary artery disease (CAD) were characterized with coronary artery calcium score (CACS) from cardiac computed tomography (CT). We analyzed plasma miRNA levels of clinical matched 11 CAC (CACS > 100) and 6 non-CAC (CACS = 0) subjects by microarray profile. Microarray analysis identified 34 differentially expressed miRNAs between CAC and non CAC groups. Eight miRNAs (miR-223, miR-3135b, miR-133a-3p, miR-2861, miR-134, miR-191-3p, miR-3679-5p, miR-1229 in CAC patients) were significantly increased in CAC plasma in an independent clinical matched cohort. Four miRNAs (miR-2861, 134, 1229 and 3135b) were correlated with the degree of CAC. Validation test in angiographic cohort showed that miR-134, miR-3135b and miR-2861 were significantly changed in patients with obstructive CAD . We identified three significantly upregulated circulating miRNAs (miR-134, miR-3135b and 2861) correlated with CAC while detected obstructive coronary disease in symptomatic patients. PMID:26537670

  5. Impact of Proximal Cap Ambiguity on Outcomes of Chronic Total Occlusion Percutaneous Coronary Intervention: Insights From a Multicenter US Registry.

    PubMed

    Karatasakis, Aris; Danek, Barbara A; Karmpaliotis, Dimitri; Alaswad, Khaldoon; Jaffer, Farouc A; Yeh, Robert W; Patel, Mitul P; Bahadorani, John N; Wyman, R Michael; Lombardi, William L; Grantham, J Aaron; Kandzari, David E; Lembo, Nicholas J; Doing, Anthony H; Moses, Jeffrey W; Kirtane, Ajay J; Garcia, Santiago; Parikh, Manish A; Ali, Ziad A; Karacsonyi, Judit; Kalra, Sanjog; Rangan, Bavana V; Kalsaria, Pratik; Thompson, Craig A; Banerjee, Subhash; Brilakis, Emmanouil S

    2016-10-01

    We sought to determine the impact of proximal cap ambiguity on procedural techniques and outcomes for coronary chronic total occlusion (CTO) percutaneous coronary intervention (PCI). We examined the clinical and angiographic characteristics and outcomes of 1021 CTO-PCIs performed between 2012 and 2015 at 11 United States centers. Proximal cap ambiguity was present in 31% of target lesions and was associated with increased clinical and angiographic complexity (prior coronary artery bypass graft surgery: 43% vs 33%; P=.01; moderate/severe calcification 66% vs 51%; P<.001) and lower technical success (85% vs 93%; P<.001) and procedural success (84% vs 91%; P=.01), but similar incidence of major adverse cardiac events (3.2% vs 2.9%; P=.77). A retrograde approach was more commonly utilized among cases with proximal cap ambiguity (68% vs 33%; P<.001), and was more likely to be the initial (39% vs 13%; P<.001) and successful approach (42% vs 20%; P<.001). Proximal cap ambiguity was associated with increased use of intravascular ultrasound (49% vs 36%; P=.01) and contrast (281 mL vs 250 mL; P<.001), higher air kerma radiation dose (4.0 Gy vs 3.0 Gy; P<.001), and longer procedure time (161 min vs 119 min; P<.001). Proximal cap ambiguity is present in one-third of CTO-PCI target lesions and is associated with lower success rates, higher utilization of the retrograde approach, and lower procedural efficiency, but no significant difference in the incidence of major adverse cardiac events.

  6. Percutaneous Coronary Intervention versus Coronary Artery Bypass Grafting in Patients with Diabetic Nephropathy and Left Main Coronary Artery Disease.

    PubMed

    Li, Hsin-Ru; Hsu, Chiao-Po; Sung, Shih-Hsien; Shih, Chun-Che; Lin, Shing-Jong; Chan, Wan-Leong; Wu, Cheng-Hsueh; Lu, Tse-Min

    2017-03-01

    Patients with diabetic nephropathy and unprotected left main (LM) coronary artery disease suffer from high cardiovascular morbidity and mortality. Although surgical revascularization is currently recommended in this special patient population, the optimal revascularization method for this distinct patient group has remained unclear. We collected 99 consecutive patients with unprotected LM disease and diabetic nephropathy, including 46 patients who had undergone percutaneous coronary intervention (PCI), and 53 who had coronary artery bypass grafting (CABG), with a mean age of 72 ± 10; with 80.8% male. Diabetic nephropathy was defined as overt proteinuria (proteinuria > 500 mg/day) and estimated glomerular filtration rate (eGFR) by the modified Modification of Diet in Renal Disease (MDRD) equation of less than 60 mL/min/1.73 m 2 . The baseline characteristics, angiographic results and long-term clinical outcomes were retrospectively analyzed. The baseline characteristic of all patients were similar except for smokers, low density lipoprotein (LDL) level and extension of coronary artery disease involvement. The median follow-up period was 3.8 years. There were 73 patients (74%) considered as high risk with additive European System for Cardiac Operative Risk Evaluation (EuroSCORE) ≥ 6. During follow-up period, the long term rate of all-cause death (PCI vs. CABG: 45.7% vs. 58.5%, p = 0.20) and all-cause death/myocardial infarction (MI)/stroke (PCI vs. CABG: 52.2% vs. 60.4%, p = 0.41) were comparable between the PCI and CABG group, whereas the repeat revascularization rate was significantly higher in the PCI group (PCI vs. CABG: 32.6% vs. 9.4%, p < 0.01). eGFR remained an independent predictor for all-cause death [hazard ratio: 0.97, 95% confidence interval: 0.96 to 0.99; p = 0.002] in multivariate logistic regression. In the real-world practice of high-risk patients with unprotected LM disease and diabetic nephropathy, we found that PCI was a comparable alternative

  7. Frequency, origins and courses of anomalous coronary arteries in 607 Turkish children with tetralogy of Fallot.

    PubMed

    Kervancioglu, Mehmet; Tokel, Kursad; Varan, Birgul; Yildirim, Selman Vefa

    2011-01-01

    The aim of this study was to investigate the incidence, origins and courses of coronary artery anomalies using a combination of angiographic and surgical methods in Turkish children with tetralogy of Fallot (ToF). Seventy-seven patients in whom coronary artery anomalies had been identified by angiography and/or at operation out of 549 ToF and 58 Fallot-type double outlet right ventricle (total 607) patients, were enrolled in the study. Coronary artery anomalies were identified in 12.7% of the patients. The incidence was 12.2% (67/549) in patients with aortic overriding 50%, and 17.2% (10/58) with aortic overriding 〉 50% (p 〉 0.05). The incidence of anomalous coronary arteries crossing the right ventricular outflow tract (RVOT) was 7.91%. The commonest anomaly was the left anterior descending artery (LAD) or accessory LAD arising from the right coronary artery (RCA; n = 25). Other frequent anomalies were single coronary ostium (n = 21) and enlarged conal branch of RCA (n = 18). In 62.3% (48/77) of the patients with a coronary anomaly, the anomalous vessels were crossing the RVOT. The ratio of crossing the RVOT was 92.0% for LAD arising from the RCA, 66.7% for conal branch, and 42.9% for single coronary ostium. Two thirds of the anomalous coronary arteries were crossing the RVOT, and had surgical importance. The most frequent coronary artery anomaly that crossed the RVOT was the LAD or the accessory LAD arising from the RCA. Also, an enlarged conus artery should be considered as an anomaly because of its surgical importance, given its high rate of crossing the RVOT.

  8. The Association between Triglyceride/High-Density Lipoprotein Cholesterol Ratio and All-Cause Mortality in Acute Coronary Syndrome after Coronary Revascularization

    PubMed Central

    Wan, Ke; Zhao, Jianxun; Huang, Hao; Zhang, Qing; Chen, Xi; Zeng, Zhi; Zhang, Li; Chen, Yucheng

    2015-01-01

    Aims High triglycerides (TG) and low high-density lipoprotein cholesterol (HDL-C) are cardiovascular risk factors. A positive correlation between elevated TG/HDL-C ratio and all-cause mortality and cardiovascular events exists in women. However, utility of TG to HDL-C ratio for prediction is unknown among acute coronary syndrome (ACS). Methods Fasting lipid profiles, detailed demographic data, and clinical data were obtained at baseline from 416 patients with ACS after coronary revascularization. Subjects were stratified into three levels of TG/HDL-C. We constructed multivariate Cox-proportional hazard models for all-cause mortality over a median follow-up of 3 years using log TG to HDL-C ratio as a predictor variable and analyzing traditional cardiovascular risk factors. We constructed a logistic regression model for major adverse cardiovascular events (MACEs) to prove that the TG/HDL-C ratio is a risk factor. Results The subject’s mean age was 64 ± 11 years; 54.5% were hypertensive, 21.8% diabetic, and 61.0% current or prior smokers. TG/HDL-C ratio ranged from 0.27 to 14.33. During the follow-up period, there were 43 deaths. In multivariate Cox models after adjusting for age, smoking, hypertension, diabetes, and severity of angiographic coronary disease, patients in the highest tertile of ACS had a 5.32-fold increased risk of mortality compared with the lowest tertile. After adjusting for conventional coronary heart disease risk factors by the logistic regression model, the TG/HDL-C ratio was associated with MACEs. Conclusion The TG to HDL-C ratio is a powerful independent predictor of all-cause mortality and is a risk factor of cardiovascular events. PMID:25880982

  9. Decreased coronary vasodilatory capacity in hypertrophic cardiomyopathy determined by split-dose thallium-dipyridamole myocardial scintigraphy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koga, Y.; Yamaguchi, R.; Ogata, M.

    1990-05-01

    Split-dose thallium-dipyridamole myocardial scintigraphy was performed in patients with nonobstructive hypertrophic cardiomyopathy (HC) who had angiographically normal coronary arteries. The dipyridamole-induced increases in thallium-201 uptake, calculated to evaluate coronary vasodilatory capacity, were significantly lower in 30 patients with HC than in 13 control subjects (177 +/- 58 vs 281 +/- 46%) and the reductions were observed in both the septal and lateral segments. The reductions of the septal segment in HC patients were significantly greater than those in 10 hypertensive patients with comparable degrees of septal hypertrophy. Of patients with HC, 16 had increases in thallium uptake well below themore » normal range. Compared with those having normal increases, these patients had significantly lower exercise duration (11 vs 15 minutes), with 33% having ST depression develop at a workload less than or equal to 80 watts. These data indicate that approximately one-half of patients with HC have impaired coronary vasodilatory capacity that could be an important pathophysiologic abnormality of HC resulting in the development of myocardial ischemia and the impairment of cardiac performance during exercise.« less

  10. Coronary intervention in thrombus-rich lesions: beyond stents and glycoprotein IIb/IIIa inhibitors.

    PubMed

    Halkin, Amir; Keren, Gad; Stone, Gregg W; Holmes, David R; Rosenschein, Uri

    2003-11-01

    Despite widespread use of stents and GP IIb/IIIa antagonists, complications following percutaneous treatment of thrombus-rich lesions continue to plague patients with ACS. In these patients the angiographically evident coronary thrombosis may represent a high degree of thrombus burden, which leads to a higher level of microembolization and its clinical sequelae. New catheter-based thrombus burden reduction systems and distal protection devices show promise for improving the prognosis of these high risk patients by decreasing distal microembolization, and thereby preventing myonecrosis. Careful procedural timing and patient selection are also likely to improve outcomes and resource utilization in the management of ACS patients.

  11. Precise correlation of histopathological and fluorescein angiographic morphology using retinal vascular casting.

    PubMed

    Bek, T; Prause, J U

    1996-12-01

    The histopathology of three eyes obtained post mortem from 2 patients with age-related macular degeneration was correlated with the pre mortem fluorescein angiographic morphology. A precise point-by-point correlation between histopathology and the corresponding angiographic appearance was ensured by using the cast retinal vascular system as a pattern of reference. The study showed that both the photoreceptors, the pigment epithelium, and substances accumulated between the retinal and the choroidal vascular systems, may have a blocking effect on choroidal background fluorescence as seen on fluorescein angiograms. Furthermore, it is confirmed that fluorescein angiographic hyperfluorescence may be due to a lack of blocking of the choroidal fluorescence because of a window defect in the retinal photoreceptor layer and/or the pigment epithelium.

  12. Cardiovascular outcomes of a positive nuclear stress test but negative coronary angiography in a multiethnic male predominant cohort.

    PubMed

    Addison, Daniel; Singh, Vinita; Okyere-Asante, K; Okafor, Henry

    2014-01-01

    Patients presenting with chest pain and evidence of functional ischemia by myocardial perfusion imaging (MPI), but lacking commensurate angiographic disease pose a diagnostic and therapeutic dilemma. They are often dismissed as having 'false-positive MPI'. Moreover, a majority of the available long-term outcome data for it has been derived from homogenous female populations. In this study, we sought to evaluate the long-term outcomes of this presentation in a multiethnic male-predominant cohort. We retrospectively identified 47 patients who presented to our institution between 2002 and 2005 with chest pain and evidence of ischemia on MPI, but with no significant angiographic disease on subsequent cardiac catheterization (cases). The occurrence of adverse cardiovascular outcomes (chest pain, congestive heart failure, acute myocardial infarction and stroke) post-index coronary angiogram was tracked. Similar data was collected for 37 patients who also presented with chest pain, but normal MPI over the same period (controls). Overall average follow-up was over 22 months. Fifty-three percent (26/47) of the cases had one or more of the adverse outcomes as compared with 22% (8/37) of controls (P < 0.01). Of these, 13 (50.0%) and 3 (37.5%) were males, respectively. Ischemia on MPI is predictive of long-term adverse cardiovascular outcomes despite normal ('false-negative') coronary angiography. This appears to be gender-neutral.

  13. Cardiovascular outcomes of a positive nuclear stress test but negative coronary angiography in a multiethnic male predominant cohort

    PubMed Central

    Addison, Daniel; Singh, Vinita; Okyere-Asante, K; Okafor, Henry

    2014-01-01

    Background: Patients presenting with chest pain and evidence of functional ischemia by myocardial perfusion imaging (MPI), but lacking commensurate angiographic disease pose a diagnostic and therapeutic dilemma. They are often dismissed as having ‘false-positive MPI’. Moreover, a majority of the available long-term outcome data for it has been derived from homogenous female populations. In this study, we sought to evaluate the long-term outcomes of this presentation in a multiethnic male-predominant cohort. Materials and Methods: We retrospectively identified 47 patients who presented to our institution between 2002 and 2005 with chest pain and evidence of ischemia on MPI, but with no significant angiographic disease on subsequent cardiac catheterization (cases). The occurrence of adverse cardiovascular outcomes (chest pain, congestive heart failure, acute myocardial infarction and stroke) post-index coronary angiogram was tracked. Similar data was collected for 37 patients who also presented with chest pain, but normal MPI over the same period (controls). Overall average follow-up was over 22 months. Results: Fifty-three percent (26/47) of the cases had one or more of the adverse outcomes as compared with 22% (8/37) of controls (P < 0.01). Of these, 13 (50.0%) and 3 (37.5%) were males, respectively. Conclusions: Ischemia on MPI is predictive of long-term adverse cardiovascular outcomes despite normal (‘false-negative’) coronary angiography. This appears to be gender-neutral. PMID:24970963

  14. Emory Angioplasty Versus Surgery Trial (EAST): design, recruitment, and baseline description of patients.

    PubMed

    King, S B; Lembo, N J; Weintraub, W S; Kosinski, A S; Barnhart, H X; Kutner, M H

    1995-03-23

    In patients with multivessel coronary artery disease who require revascularization there is uncertainty as to the selection of the appropriate patients for percutaneous transluminal coronary angioplasty (PTCA) as opposed to coronary artery bypass grafting (CABG). To define the relative roles of PTCA and CABG for multivessel disease, 392 patients were randomly assigned to revascularization by PTCA or CABG and followed for 3 years. This is a single-center randomized study in which individual group assignment was known but grouped data remained blinded until a full 3 years of follow-up was complete on all patients. The patients were randomized in 4 strata: (1) 2-vessel disease with 1 lesion per vessel; (2) 2-vessel disease with multiple lesions in at least 1 vessel; (3) 3-vessel disease with 1 lesion per vessel; and (4) 3-vessel disease with multiple lesions in at least 1 vessel. All data were collected on study-specific forms and sent to an independent biostatistical coordinating center for entry into a computerized database. All data will be analyzed by intention-to-treat. The primary endpoint of the trial is the composite of death of any cause, Q-wave myocardial infarction within 3 years, or a large reversible thallium defect at 3 years. Multiple secondary endpoints will include each of the components of the primary endpoint, the need for additional procedures, angiographic status at 1 and 3 years measured by an independent quantitative coronary arteriography laboratory, and measures of quality of life. A total of 5,118 patients were screened, of whom 3,371 were excluded for angiographic reasons, 191 because the angioplasty operators or surgeons believed that the patients were anatomically unsuitable, and 714 for clinical exclusions, leaving 842 eligible patients, of whom 392 were randomized. Of these, 40% had triple-vessel disease and 60% had double-vessel disease. There was no baseline difference between the 2 treatment arms for any clinical or major angiographic

  15. True coronary bifurcation lesions: meta-analysis and review of literature.

    PubMed

    Athappan, Ganesh; Ponniah, Thirumalaikolundiusubramanian; Jeyaseelan, Lakshmanan

    2010-02-01

    Percutaneous intervention of true coronary bifurcation lesions is challenging. Based on the results of randomized trials and registry data, the approach of stenting of main vessel only with balloon dilatation of the side branch has become the default approach for false bifurcation lesions except when a complication occurs or in cases of suboptimal result. However, the optimal stenting strategy for true coronary bifurcation lesions - to stent or not to stent the side branch - is still a matter of debate. The purpose of this study was, therefore, to compare the clinical and angiographic outcomes of the double stent technique (stenting of the main branch and side branch) over the single stent technique (stenting of main vessel only with balloon dilatation of the side branch) for treatment of true coronary bifurcation lesions, with drug-eluting stents (DES). Comparative studies published between January 2000 and February 2009 of the double stent technique vs. single stent technique with DES for true coronary bifurcations were identified using an electronic search and reviewed using a random effects model. The primary endpoints of our study were side-branch and main-branch restenoses, all-cause mortality, myocardial infarction (MI) and target lesion revascularization (TLR) at longest available follow-up. The secondary endpoints of our analysis were postprocedural minimal luminal diameter (MLD) of the side branch and main branch, follow-up MLD of side branch and main branch and stent thrombosis. Heterogeneity was assessed and sensitivity analysis was performed to test the robustness of the overall summary odds ratios (ORs). Five studies comprising 1145 patients (616 single stent and 529 double stent) were included in the analysis. Three studies were randomized comparisons between the two techniques for true coronary bifurcation lesions. Incomplete reporting of data in the primary studies was common. The lengths of clinical and angiographic follow-up ranged between 6 and

  16. Three Variations in Rabbit Angiographic Stroke Models

    PubMed Central

    Culp, William C.; Woods, Sean D.; Brown, Aliza T.; Lowery, John D.; Hennings, Leah J.; Skinner, Robert D.; Borrelli, Michael J.; Roberson, Paula K.

    2012-01-01

    Purpose To develop angiographic models of embolic stroke in the rabbit using pre-formed clot or microspheres to model clinical situations ranging from transient ischemic events to severe ischemic stroke. Materials and Methods New Zealand White rabbits (N=151) received angiographic access to the internal carotid artery (ICA) from a femoral approach. Variations of emboli type and quantity of emboli were tested by injection into the ICA. These included fresh clots (1.0-mm length, 3–6 h), larger aged clots (4.0-mm length, 3 days), and 2 or 3 insoluble microspheres (700–900 μm). Neurological assessment scores (NAS) were based on motor, sensory, balance, and reflex measures. Rabbits were euthanized at 4, 7, or 24 hours after embolization, and infarct volume was measured as a percent of total brain volume using 2,3,5-triphenyltetrazolium chloride (TTC). Results Infarct volume percent at 24 hours after stroke was lower for rabbits embolized with fresh clot (0.45% ± 0.14%), compared with aged clot (3.52% ± 1.31%) and insoluble microspheres (3.39% ± 1.04%). Overall NAS (including posterior vessel occlusions) were positively correlated to infarct volume percent measurements in the fresh clot (r=0.50), aged clot (r=0.65) and microsphere (r=0.62) models (p<0.001). Conclusion The three basic angiographic stroke models may be similar to human transient ischemic attacks (TIA) (fresh clot), major strokes that can be thrombolysed (aged clot), or major strokes with insoluble emboli such as atheromata (microspheres). Model selection can be tailored to specific research needs. PMID:23142182

  17. Relation of ABO blood groups to the severity of coronary atherosclerosis: an Gensini score assessment.

    PubMed

    Gong, Ping; Luo, Song-Hui; Li, Xiao-Lin; Guo, Yuan-Lin; Zhu, Cheng-Gang; Xu, Rui-Xia; Li, Sha; Dong, Qian; Liu, Geng; Chen, Juan; Zeng, Rui-Xiang; Li, Jian-Jun

    2014-12-01

    Although the study on the relationship between ABO blood groups and coronary atherosclerosis has a long history, few data is available regarding ABO to severity of coronary atherosclerosis in a large cohort study. Therefore, the present study aimed to investigate the relation of the ABO blood groups to the severity of coronary atherosclerosis assessed by Gensini score (GS) in a large Chinese cohort undergoing coronary angiography. A total of 2919 consecutive patients undergoing coronary angiography were enrolled, and their baseline characteristics and ABO blood groups were collected. The GS was calculated as 1st tertile (0-10), 2nd tertile (11-36), 3rd tertile (>36) according to angiographic results. The relation of the ABO blood groups to GS was investigated. The frequency of blood group A was significantly higher in the upper GS tertiles (24.4% vs. 28.2% vs. 29.5%, p = 0.032). Multivariable linear regression analysis revealed that blood group A was independently associated with GS (β = 0.043, p = 0.017). Likewise, multivariable logistic regression analysis showed that group A remained significantly associated with mid-high GS (OR = 1.44, 95% CI 1.16-1.80, p = 0.001), and the group O was showed as a protective factor (OR = 0.77, 95% CI = 0.65-0.92, p = 0.004). In this large Chinese cohort study, the data indicated that there was an association between ABO blood groups and the severity of coronary atherosclerosis. Moreover, the blood group A was an independent risk factor for serious coronary atherosclerosis. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  18. Morphology-based three-dimensional segmentation of coronary artery tree from CTA scans

    NASA Astrophysics Data System (ADS)

    Banh, Diem Phuc T.; Kyprianou, Iacovos S.; Paquerault, Sophie; Myers, Kyle J.

    2007-03-01

    We developed an algorithm based on a rule-based threshold framework to segment the coronary arteries from angiographic computed tomography (CTA) data. Computerized segmentation of the coronary arteries is a challenging procedure due to the presence of diverse anatomical structures surrounding the heart on cardiac CTA data. The proposed algorithm incorporates various levels of image processing and organ information including region, connectivity and morphology operations. It consists of three successive stages. The first stage involves the extraction of the three-dimensional scaffold of the heart envelope. This stage is semiautomatic requiring a reader to review the CTA scans and manually select points along the heart envelope in slices. These points are further processed using a surface spline-fitting technique to automatically generate the heart envelope. The second stage consists of segmenting the left heart chambers and coronary arteries using grayscale threshold, size and connectivity criteria. This is followed by applying morphology operations to further detach the left and right coronary arteries from the aorta. In the final stage, the 3D vessel tree is reconstructed and labeled using an Isolated Connected Threshold technique. The algorithm was developed and tested on a patient coronary artery CTA that was graciously shared by the Department of Radiology of the Massachusetts General Hospital. The test showed that our method constantly segmented the vessels above 79% of the maximum gray-level and automatically extracted 55 of the 58 coronary segments that can be seen on the CTA scan by a reader. These results are an encouraging step toward our objective of generating high resolution models of the male and female heart that will be subsequently used as phantoms for medical imaging system optimization studies.

  19. Evidence for association of a common variant of the endothelial nitric oxide synthase gene (Glu298→Asp polymorphism) to the presence, extent, and severity of coronary artery disease

    PubMed Central

    Colombo, M G; Andreassi, M G; Paradossi, U; Botto, N; Manfredi, S; Masetti, S; Rossi, G; Clerico, A; Biagini, A

    2002-01-01

    Background: Genetic variants of endothelial nitric oxide synthase (eNOS) could influence individual susceptibility to coronary artery disease. Objective: To assess whether Glu298→Asp polymorphism of the eNOS gene is associated with the occurrence and severity of angiographically defined coronary artery disease in the Italian population. Methods: Polymerase chain reaction/restriction fragment length polymorphism analysis was done to detect the Glu298→Asp variant of the eNOS gene in 201 patients with coronary artery disease and 114 controls. The severity of coronary artery disease was expressed by the number of affected vessels and by the Duke scoring system. Results: The frequencies of the eNOS Glu/Glu, Glu/Asp, and Asp/Asp genotypes in the coronary artery disease group were significantly different from those of controls (45.3%, 38.8%, and 15.9% v 42.1%, 51.8%, and 6.1%, respectively; χ2 = 8.589, p = 0.0136). In comparison with subjects who had a Glu298 allele in the eNOS gene, the risk of coronary artery disease was increased among Asp/Asp carriers (odds ratio 2.9, 95% confidence interval 1.2 to 6.8, p = 0.01) and was independent of the other common risk factors (p = 0.04). There was a significant association between the eNOS Glu298→Asp variant and both the number of stenosed vessels (mean (SEM), 2.3 (0.1) for Asp/Asp v 1.9 (0.1) and 1.8 (0.1) for Glu/Glu and Glu/Asp, respectively; p = 0.01) and the Duke score (56.1 (3.1) for Asp/Asp v 46.7 (2.0) and 46.1 (1.9) for Glu/Glu and Glu/Asp, respectively; p = 0.02). Conclusions: Glu298→Asp polymorphism of the eNOS gene appears to be associated with the presence, extent, and severity of angiographically assessed coronary artery disease. PMID:12010932

  20. Computer quantitation of coronary angiograms

    NASA Technical Reports Server (NTRS)

    Ledbetter, D. C.; Selzer, R. H.; Gordon, R. M.; Blankenhorn, D. H.; Sanmarco, M. E.

    1978-01-01

    A computer technique is being developed at the Jet Propulsion Laboratory to automate the measurement of coronary stenosis. A Vanguard 35mm film transport is optically coupled to a Spatial Data System vidicon/digitizer which in turn is controlled by a DEC PDP 11/55 computer. Programs have been developed to track the edges of the arterial shadow, to locate normal and atherosclerotic vessel sections and to measure percent stenosis. Multiple frame analysis techniques are being investigated that involve on the one hand, averaging stenosis measurements from adjacent frames, and on the other hand, averaging adjacent frame images directly and then measuring stenosis from the averaged image. For the latter case, geometric transformations are used to force registration of vessel images whose spatial orientation changes.

  1. Aqueous Angiography–Mediated Guidance of Trabecular Bypass Improves Angiographic Outflow in Human Enucleated Eyes

    PubMed Central

    Huang, Alex S.; Saraswathy, Sindhu; Dastiridou, Anna; Begian, Alan; Mohindroo, Chirayu; Tan, James C. H.; Francis, Brian A.; Hinton, David R.; Weinreb, Robert N.

    2016-01-01

    Purpose To assess the ability of trabecular micro-bypass stents to improve aqueous humor outflow (AHO) in regions initially devoid of AHO as assessed by aqueous angiography. Methods Enucleated human eyes (14 total from 7 males and 3 females [ages 52–84]) were obtained from an eye bank within 48 hours of death. Eyes were oriented by inferior oblique insertion, and aqueous angiography was performed with indocyanine green (ICG; 0.4%) or fluorescein (2.5%) at 10 mm Hg. With an angiographer, infrared and fluorescent images were acquired. Concurrent anterior segment optical coherence tomography (OCT) was performed, and fixable fluorescent dextrans were introduced into the eye for histologic analysis of angiographically positive and negative areas. Experimentally, some eyes (n = 11) first received ICG aqueous angiography to determine angiographic patterns. These eyes then underwent trabecular micro-bypass sham or stent placement in regions initially devoid of angiographic signal. This was followed by fluorescein aqueous angiography to query the effects. Results Aqueous angiography in human eyes yielded high-quality images with segmental patterns. Distally, angiographically positive but not negative areas demonstrated intrascleral lumens on OCT images. Aqueous angiography with fluorescent dextrans led to their trapping in AHO pathways. Trabecular bypass but not sham in regions initially devoid of ICG aqueous angiography led to increased aqueous angiography as assessed by fluorescein (P = 0.043). Conclusions Using sequential aqueous angiography in an enucleated human eye model system, regions initially without angiographic flow or signal could be recruited for AHO using a trabecular bypass stent. PMID:27588614

  2. Angiographic Method Using Green Porphyrinew In Primmate Eyes

    DOEpatents

    Miller, Joan W.; Young, Lucy H.Y.; Gragoudas, Evangelos S.

    1998-01-13

    An angiographic method to observe the condition of blood vessels, including neovasculature in the eyes of living primates using green porphyrins and light at a wavelength of 550-700 nm to effect fluorescence is disclosed.

  3. Prognostic significance of normal quantitative Tl-201 stress scintigraphy in relation to pretest likelihood of coronary artery disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Russo, D.J.; Russo, D.; Clements, J.

    A previous study reported an excellent prognosis and low cardiac event rate in patients(pts) with chest pain and normal quantitative T1-201 scintigraphy(SC). Such result would not be unexpected if the population under study had a predominance of pts with low pre-T1-201 likelihood(L) of significant coronary artery disease (CAD). Hence, the authors undertook telephone follow-up in pts with chest pain syndrome and normal quantitative T1-201 exercise SC, and related outcome to pretest L of CAD. Pretest L was determined by serial L analysis on the basis of: symptoms, age, sex, and exercise ECG. All pts had T1-201 SC immediately post exercisemore » and 2 hrs later. After interpolative background correction, circumferential count and washout profiles were generated. All pts had unequivocally normal studies. Of a total of 96 pts studied in 1981-82, 20 pts were lost to follow-up. Of the remaining 76 pts, 45 were males and 31 females. The pretest L of CAD had an inverted Gaussian distribution: thirty-four pts(47%) had <33% L of CAD, 3 pts (5%) had 33-66% L of CAD, and 35 pts(48%) had >66% L of CAD. Mean follow-up was 22+- 3 months. No deaths occurred. Two pts(3%) (with pretest L of 54% and 94%) had myocardial infarctions, 8 and 22 months respectively after T1-201 stress SC. One pt underwent percutaneous transluminal coronary angioplasty (PTCA) 16 months after T1-201 stress SC. These findings confirm excellent prognostic significance of normal quantitative T1-201 stress scintigraphy.« less

  4. Off-pump coronary artery bypass grafting. The 1st Medical Faculty of Charles University study.

    PubMed

    Semrád, M; Bodlák, P; Stríteský, M; Kristof, J; Lindner, J; Urban, T; Vondrácek, V; Vanĕk, I

    2002-01-01

    To explore the surgical technique, anaesthesiological management, immediate and mid-term results, graft patency and effectiveness of less invasive coronary artery bypass grafting through a median sternotomy. From January 1998 through December 1999, 144 patients had coronary artery bypass grafting (CABG) without cardiopulmonary bypass (CPB) done by one surgeon through a median sternotomy. The cohort of 107 men and 37 women averaged 60.8 years, mean ejection fraction (EF) was 51.8%. An average of 2.7 (range 1 to 5) grafts/patients was achieved. Results are compared with a CPB subgroup of patients operated on through a median sternotomy in the same time (N = 234). In a random subgroup of 100 patients (50 per group) an angiographic control of graft patency was done. A non-CPB group showed less postoperative acute myocardial infarction (0.7% vs. 3.8%, p < 0.05) and atrial fibrillation (14.6% vs. 26%, p < 0.05), lower incidence of renal (2.8% vs. 5.1%, p < 0.05) and respiratory complications (2.0% vs. 3.8%, NS). We observed lower operative mortality (0.7% vs. 3.4%, p < 0.05), as well as the occurrence of low cardiac output syndrome (0.7% vs. 5.6%, p < 0.05) in the off-pump group. The follow-up is 36 +/- 12 months and the number of patients with recurrent angina, late AMI and late death is acceptable. We did not find an inordinate number of vein grafts occlusions (0.7% vs. 1.8%, NS) and stenoses (6.6% vs. 6.7%, NS) at anastomotic sites. None of the arterial grafts in both groups were occluded. There was little known about the efficacy of the less invasive coronary artery bypass grafting at the beginning of our study. Starting with pioneering the operative technique, we have discovered and proposed three types of a heart verticalization and a reusable stabilizing device. We detected lower incidence of postoperative complications and decreased operative mortality in a non-CPB group. Angiographic assessment displayed an excellent run-off in both groups of patients. Off

  5. The relation between intensity and complexity of coronary artery lesion and oxidative stress in patients with acute coronary syndrome.

    PubMed

    Turan, Turhan; Menteşe, Ümit; Ağaç, Mustafa Tarık; Akyüz, Ali Rıza; Kul, Selim; Aykan, Ahmet Çağrı; Bektaş, Hüseyin; Korkmaz, Levent; Öztaş Menteşe, Seda; Dursun, İhsan; Çelik, Şükrü

    2015-10-01

    Oxidative stress plays a major role in the development of atherosclerosis. However, the relationship between oxidative stress and complexity and intensity of coronary artery disease is less clear. The aim of this study is to assess the relationship between oxidative stress markers and the complexity and intensity of coronary artery disease in patients with acute coronary syndrome (ACS). Sixty-seven consecutive patients with an early phase of ACS (<3 h) were included in this single-centre, cross-sectional, prospective study. Syntax and Gensini scores were calculated based on angiographic findings. Patients were divided into two CAD complexity groups according to their Syntax scores: low SYNTAX score (<22) and moderate to high SYNTAX score (>=22). Likewise patients were divided into two CAD severity groups according to the median Gensini score of 64: less intensive CAD with Gensini score (<64) and intensive CAD with Gensini score >=64. Blood samples were taken in 1 hour within administration in order to measure total oxidative status (TOS) and total antioxidant capacity (TAC) levels determined by Erel method. Oxidative stress index (OSI) was calculated by TOS /TAC. There was no significant difference between the two SYNTAX groups for oxidative stress markers. Median TOS and OSI values were significantly high in the intensive CAD group (p=0.005, p=0.04, respectively). The Gensini score was positively correlated with TOS and OSI (p=0.003, p=0.02, respectively). Oxidative stress markers may be considered supportive laboratory parameters related to CAD intensity but not complexity in ACS patients.

  6. Predicting coronary artery disease using different artificial neural network models.

    PubMed

    Colak, M Cengiz; Colak, Cemil; Kocatürk, Hasan; Sağiroğlu, Seref; Barutçu, Irfan

    2008-08-01

    Eight different learning algorithms used for creating artificial neural network (ANN) models and the different ANN models in the prediction of coronary artery disease (CAD) are introduced. This work was carried out as a retrospective case-control study. Overall, 124 consecutive patients who had been diagnosed with CAD by coronary angiography (at least 1 coronary stenosis > 50% in major epicardial arteries) were enrolled in the work. Angiographically, the 113 people (group 2) with normal coronary arteries were taken as control subjects. Multi-layered perceptrons ANN architecture were applied. The ANN models trained with different learning algorithms were performed in 237 records, divided into training (n=171) and testing (n=66) data sets. The performance of prediction was evaluated by sensitivity, specificity and accuracy values based on standard definitions. The results have demonstrated that ANN models trained with eight different learning algorithms are promising because of high (greater than 71%) sensitivity, specificity and accuracy values in the prediction of CAD. Accuracy, sensitivity and specificity values varied between 83.63%-100%, 86.46%-100% and 74.67%-100% for training, respectively. For testing, the values were more than 71% for sensitivity, 76% for specificity and 81% for accuracy. It may be proposed that the use of different learning algorithms other than backpropagation and larger sample sizes can improve the performance of prediction. The proposed ANN models trained with these learning algorithms could be used a promising approach for predicting CAD without the need for invasive diagnostic methods and could help in the prognostic clinical decision.

  7. Flat panel digital detector cinefluoroscopy late following SES or BMS implantation for detection of coronary stent fracture in asymptomatic patients.

    PubMed

    Davlouros, Periklis A; Chefneux, Corina; Xanthopoulou, Ioanna; Papathanasiou, Maria; Zaharioglou, Evaggelia; Tsigkas, Grigorios; Alexopoulos, Dimitrios

    2012-05-03

    Coronary stent fracture (SF), is rare and confined mainly in patients treated with sirolimus eluting stents (SES). The role of flat panel digital detector (FPDD) fluoroscopy in detecting SF has not been investigated. Assessment with FPDD fluoroscopy of asymptomatic patients, with 200 SES (Cypher, Cordis, J&J, Miami, Florida, US), and 200 bare metal stents (BMS), at 45.5 ± 15.7 and 38.4 ± 3.9 months post-stenting respectively. SF was defined as discontinuity of stent struts on fluoroscopy. Coronary angiography was reserved for patients with documented SF. Effective radiation dose was 0.26 ± 0.14 mSv. SF was depicted in 6 (3%) SES, and 1 BMS (0.5%). Stent length was an independent predictor of SF (OR 1.19, 95% CI 1.03-1.4, p=0.024). RCA location and vessel angulation were marginally significant (OR 7.7, 95% CI 0.8-74.2, p=0.077 and OR 5.1, 95% CI 0.8-34, p=0.089). Significant angiographic restenosis was detected in 4 SES (66.6%), and 1 BMS (0.5%). Re-intervention was needed in 3 (42.8%) cases, (2 SES and 1 BMS). Detection of SF with FPDD cinefluoroscopy late following coronary stenting is feasible, involves low radiation and is confined mainly to SES compared to BMS. Application of cinefluoroscopy as part of a routine stent surveillance programme in asymptomatic patients may be more appropriate in "high risk" settings (SES, long stents and adverse angiographic characteristics). The role of invasive imaging and subsequent management of such patients need further studying. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  8. Aspirin plus clopidogrel for optimal platelet inhibition following off-pump coronary artery bypass surgery: results from the CRYSSA (prevention of Coronary arteRY bypaSS occlusion After off-pump procedures) randomised study.

    PubMed

    Mannacio, Vito Antonio; Di Tommaso, Luigi; Antignan, Anita; De Amicis, Vincenzo; Vosa, Carlo

    2012-12-01

    To determine the individual variability in the response to aspirin and/or clopidogrel and its impact on graft patency after off-pump coronary artery bypass grafting. A single-centre prospective randomised controlled study designed according to the Consolidated Standards of Reporting Trials statement. Randomisation was obtained by a computer-generated algorithm. University medical school in Italy. 300 patients who underwent off-pump coronary artery bypass grafting were randomised to receive aspirin (n=150) or aspirin plus clopidogrel (n=150). Aspirin 100 mg or aspirin 100 mg plus clopidogrel 75 mg daily was initiated when postoperative chest tube drainage was ≤ 50 ml/h for 2 h and patients were followed up for 12 months. Qualitative and quantitative assessment of platelet function, angiographic evaluation of coronary revascularisation by 64-slice CT and clinical outcome. In the aspirin group, 49 patients (32.6%) were aspirin resistant and, in the aspirin-clopidogrel group, 19 patients (12.6%) were aspirin and clopidogrel resistant. The platelet response to aspirin was similar in all aspirin responders despite the study arm (Aspirin Reaction Units 313.2 ± 44.8 vs 323.6 ± 53.6; p=0.07). The platelet response to clopidogrel was enhanced by aspirin in patients responsive to both aspirin and clopidogrel (synergistic effect) compared with responders to clopidogrel only (P2Y12 Reaction Units 139.9 ± 15.5 vs 179.4 ± 18.5; p<0.001). Combined therapy was associated with a reduced vein graft occlusion rate (7.4% vs 13.1%; p=0.04). Antiplatelet resistance was a predictor of graft occlusion (RR 3.6, 95% CI 2.5 to 6.9; p<0.001). Synergistic aspirin and clopidogrel activity was a strong predictor of vein graft patency (RR 5.1, 95% CI 1.4 to 16.3; p<0.01). Combined clopidogrel and aspirin overcome single drug resistances, are safe for bleeding and improve venous graft patency.

  9. Coronary Artery Disease: Analysis of Diagnostic Performance of CT Perfusion and MR Perfusion Imaging in Comparison with Quantitative Coronary Angiography and SPECT-Multicenter Prospective Trial.

    PubMed

    Rief, Matthias; Chen, Marcus Y; Vavere, Andrea L; Kendziora, Benjamin; Miller, Julie M; Bandettini, W Patricia; Cox, Christopher; George, Richard T; Lima, João; Di Carli, Marcelo; Plotkin, Michail; Zimmermann, Elke; Laule, Michael; Schlattmann, Peter; Arai, Andrew E; Dewey, Marc

    2018-02-01

    Purpose To compare the diagnostic performance of stress myocardial computed tomography (CT) perfusion with that of stress myocardial magnetic resonance (MR) perfusion imaging in the detection of coronary artery disease (CAD). Materials and Methods All patients gave written informed consent prior to inclusion in this institutional review board-approved study. This two-center substudy of the prospective Combined Noninvasive Coronary Angiography and Myocardial Perfusion Imaging Using 320-Detector Row Computed Tomography (CORE320) multicenter trial included 92 patients (mean age, 63.1 years ± 8.1 [standard deviation]; 73% male). All patients underwent perfusion CT and perfusion MR imaging with either adenosine or regadenoson stress. The predefined reference standards were combined quantitative coronary angiography (QCA) and single-photon emission CT (SPECT) or QCA alone. Results from coronary CT angiography were not included, and diagnostic performance was evaluated with the Mantel-Haenszel test stratified by disease status. Results The prevalence of CAD was 39% (36 of 92) according to QCA and SPECT and 64% (59 of 92) according to QCA alone. When compared with QCA and SPECT, per-patient diagnostic accuracy of perfusion CT and perfusion MR imaging was 63% (58 of 92) and 75% (69 of 92), respectively (P = .11); sensitivity was 92% (33 of 36) and 83% (30 of 36), respectively (P = .45); and specificity was 45% (25 of 56) and 70% (39 of 56), respectively (P < .01). When compared with QCA alone, diagnostic accuracy of CT perfusion and MR perfusion imaging was 82% (75 of 92) and 74% (68 of 92), respectively (P = .27); sensitivity was 90% (53 of 59) and 69% (41 of 59), respectively (P < .01); and specificity was 67% (22 of 33) and 82% (27 of 33), respectively (P = .27). Conclusion This multicenter study shows that the diagnostic performance of perfusion CT is similar to that of perfusion MR imaging in the detection of CAD. © RSNA, 2017 Online supplemental material is

  10. Quantitative coronary angiography using image recovery techniques for background estimation in unsubtracted images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wong, Jerry T.; Kamyar, Farzad; Molloi, Sabee

    2007-10-15

    Densitometry measurements have been performed previously using subtracted images. However, digital subtraction angiography (DSA) in coronary angiography is highly susceptible to misregistration artifacts due to the temporal separation of background and target images. Misregistration artifacts due to respiration and patient motion occur frequently, and organ motion is unavoidable. Quantitative densitometric techniques would be more clinically feasible if they could be implemented using unsubtracted images. The goal of this study is to evaluate image recovery techniques for densitometry measurements using unsubtracted images. A humanoid phantom and eight swine (25-35 kg) were used to evaluate the accuracy and precision of the followingmore » image recovery techniques: Local averaging (LA), morphological filtering (MF), linear interpolation (LI), and curvature-driven diffusion image inpainting (CDD). Images of iodinated vessel phantoms placed over the heart of the humanoid phantom or swine were acquired. In addition, coronary angiograms were obtained after power injections of a nonionic iodinated contrast solution in an in vivo swine study. Background signals were estimated and removed with LA, MF, LI, and CDD. Iodine masses in the vessel phantoms were quantified and compared to known amounts. Moreover, the total iodine in left anterior descending arteries was measured and compared with DSA measurements. In the humanoid phantom study, the average root mean square errors associated with quantifying iodine mass using LA and MF were approximately 6% and 9%, respectively. The corresponding average root mean square errors associated with quantifying iodine mass using LI and CDD were both approximately 3%. In the in vivo swine study, the root mean square errors associated with quantifying iodine in the vessel phantoms with LA and MF were approximately 5% and 12%, respectively. The corresponding average root mean square errors using LI and CDD were both 3%. The standard

  11. [Coronary disease with normal coronarography in the black Africans: epidemiological and clinical data in 31 cases. Role of abnormal hemoglobins].

    PubMed

    Bertrand, E; Renambot, J; Chauvet, J; Seka, R; Ticolat, R; Odi Assamoi, M; Ndori, R; Ekra, A

    1993-04-01

    The authors studied 31 cases of coronary artery disease with normal or minimally diseases coronary arteries in black Africans, 29.8% of 104 coronary patients undergoing coronary angiography in this series. These 31 cases comprised 16 cases of infarction, 10 cases of angina, 3 ventricular aneurysms and 2 cases of silent ischemia in diabetic patients. Twenty-five patients were men (80.6%). There were 6 women (19.3%) two of whom presented in the post-partum period. The average age of these patients was 45 years (males: 47.7 years; females: 41.8 years). The following risk factors were noted: smoking (60%), hypertension (25.8%), obesity (29%), diabetes (12.9%), serum cholesterol (average 2.15 g/l), serum triglycerides (average 1.25 g/l). The risk index per patient was 1.29. In comparison with coronary patients with angiographic coronary lesions (n = 73), the patients with normal angiography were significantly younger, comprised more females and had fewer risk factors (especially hypertension and diabetes), though this was not statistically significant. The prevalence of inaugural infarction was 81.2% in the cases of infarction with normal coronary arteries. These infarcts may be complicated by ventricular aneurysm formation. Spontaneous spasm was observed in 3 out of 31 patients (9.6%) at coronary angiography. A provocative test was performed in only 2 cases and 1 was positive. This deserves further study and may have therapeutic implications. The authors emphasise the high incidence of hemoglobin S or C traits (57.1%). These heterozygotic hemoglobinopathies could be a risk factor in these coronary patients with normal coronary angiography.

  12. Transcatheter vessel occlusion: angiographic results versus clinical success

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feldman, L.; Greenfield, A.J.; Waltman, A.C.

    1983-04-01

    A review was made of 219 transcatheter vessel occlusion procedures performed over a ten-year period for control of hemorrhage, tumor palliation, or blood supply redistribution prior to intra-arterial chemotherapy. Complete angiographic success was obtained in 85% of the procedures, with partial success in 8%; complete clinical success was achieved in 53% of patients, with partial success in 23%. the most satisfactory clinical results were obtained with hemorrhagic gastritis and pelvic trauma. Embolizations for duodenal ulcer hemorrhage and transhepatic variceal occlusion were the least clinically successful, although isobutyl-cyanoacrylate appeared to be a significant improvement in angiographic therapy for duodenal ulcer. Themore » overall complication rate was 13%, with one third of the complications clinically silent. These results indicate that transcatheter vessel occlusion is a relatively safe and effective method for control of hemorrhage or tumor infarction.« less

  13. Comparison of long-term mortality of acute ST-segment elevation myocardial infarction and non-ST-segment elevation acute coronary syndrome patients after percutaneous coronary intervention

    PubMed Central

    Ren, Lihui; Ye, Huiming; Wang, Ping; Cui, Yuxia; Cao, Shichang; Lv, Shuzheng

    2014-01-01

    Background and aims: This study is to compare the short-term and long-term mortality in patients with ST-segment elevation myocardial infarction (STEMI) and non-ST-segment elevation acute coronary syndrome (NSTE-ACS) after percutaneous coronary intervention (PCI). Methods and results: A total of 266 STEMI patients and 140 NSTE-ACS patients received PCI. Patients were followed up by telephone or at medical record or case statistics center and were followed up for 4 years. Descriptive statistics and multivariate survival analyses were employed to compare the mortality in STEMI and NSTE-ACS. All statistical analyses were performed by SPSS19.0 software package. NSTE-ACS patients had significantly higher clinical and angiographic risk profiles at baseline. During the 4-year follow-up, all-cause mortality in STEMI was significantly higher than that in NSTE-ACS after coronary stent placement (HR 1.496, 95% CI 1.019-2.197). In a landmark analysis no difference was seen in all-cause mortality for both STEMI and NSTE-ACS between 6 month and 4 years of follow-up (HR 1.173, 95% CI 0.758-1.813). Conclusions: Patients with STEMI have a worse long-term prognosis compared to patients with NSTE-ACS after PCI, due to higher short-term mortality. However, NSTE-ACS patients have a worse long-term survival after 6 months. PMID:25664077

  14. Primary percutaneous coronary intervention by magnetic navigation compared with conventional wire technique.

    PubMed

    Patterson, Mark S; Dirksen, Maurits T; Ijsselmuiden, Alexander J; Amoroso, Giovanni; Slagboom, Ton; Laarman, Gerrit-Jan; Schultz, Carl; van Domburg, Ron T; Serruys, Patrick W; Kiemeneij, Ferdinand

    2011-06-01

    Aims Comparison of magnetic guidewire navigation in percutaneous coronary intervention (MPCI) vs. conventional percutaneous coronary intervention (CPCI) for the treatment of acute myocardial infarction. Methods and results We compared 65 sequential patients (mean age 61 ± 15 years) undergoing primary MPCI with those of 405 patients undergoing CPCI (mean age 61 ± 13 years). The major endpoint was contrast media use. Technical success and procedural outcomes were evaluated. Clinical demographics and angiographic characteristics of the two groups were similar, except for fewer patients with previous coronary artery bypass grafting (CABG) and hypertension in the CPCI group and fewer patients with diabetes in the MPCI group. The technical success rate was high in both the MPCI and CPCI groups (95.4 vs. 98%). There was significantly less contrast media usage in the MPCI compared with the CPCI group, median reduction of contrast media of 30 mL with an OR = 0.41 (0.21-0.81). Fluoroscopy times were significantly reduced for MPCI compared with CPCI, median reduction of 7.2 min with an OR = 0.42 (0.20-0.79). Conclusion This comparison indicates the feasibility and non-inferiority of magnetic navigation in performing primary PCI and suggests the possibility of reductions in contrast media use and fluoroscopy time compared with CPCI.

  15. Triggering of acute coronary occlusion by episodes of anger.

    PubMed

    Buckley, Thomas; Hoo, Soon Y Soo; Fethney, Judith; Shaw, Elizabeth; Hanson, Peter S; Tofler, Geoffrey H

    2015-12-01

    The aim of this study was to report the association between episodes of anger and acute myocardial infarction (MI) in patients with angiographically confirmed coronary occlusion. 313 participants with acute coronary occlusion (Thrombolysis In Myocardial Infarction 0 or 1 at emergency angiography) reported frequency of anger episodes in the 48 h prior to MI. In primary analysis, anger exposures within 2 h and 2-4 h prior to symptom onset were compared with subjects' own usual yearly exposure to anger using case-crossover methodology. Anger level ≥5 (on an anger scale of 1-7) was reported by seven (2.2%) participants within 2 h of MI. Compared with usual frequency, the relative risk of onset of MI symptoms occurring within 2 h of anger level ≥5 (defined as very angry) was 8.5 (95% confidence interval 4.1-17.6). Anger level <5 was not associated with onset of MI symptoms. Compared with 24-26 h pre MI, anxiety scores >75th percentile on State-Trait Personality Inventory were associated with a relative risk of 2.0 (95% confidence interval 1.1-3.8) and in those above the 90th percentile, the relative risk of MI symptom onset was 9.5 (95% confidence interval 2.2-40.8). Findings confirm that episodes of intense anger, defined as being 'very angry, body tense, clenching fists or teeth' (within 2 h) are associated with increased relative risk for acute coronary occlusion. Additionally, increased anxiety was associated with coronary occlusion. Further study, including the role of potential modifiers, may provide insight into prevention of MI during acute emotional episodes. © The European Society of Cardiology 2015.

  16. Follow-up status of patients with angiographically normal coronary arteries and panic disorder

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beitman, B.D.; Kushner, M.G.; Basha, I.

    1991-03-27

    Cardiology patients with normal coronary angiography demonstrate continuing and substantial social, health, and work disability. The authors hypothesized that the diagnosis of panic disorder would mark those for whom continuing disability is most likely. They interviewed 72 such patients at the time of their normal angiogram, and then again an average of 38 months later. Those with panic disorder (n=36) demonstrated significantly more disability at follow-up than did the other study patients. They conclude that those patients with normal angiograms who have panic disorder are more disabled than those who do not have panic disorder. Panic disorder in psychiatric samplesmore » has been shown to be highly treatable. Therefore, early identification and treatment of panic disorder in this group is likely to minimize the suffering associated with this condition.« less

  17. Everolimus-eluting bioresorbable vascular scaffolds implanted in coronary bifurcation lesions: Impact of polymeric wide struts on side-branch impairment.

    PubMed

    De Paolis, Marcella; Felix, Cordula; van Ditzhuijzen, Nienke; Fam, Jiang Ming; Karanasos, Antonis; de Boer, Sanneke; van Mieghem, Nicolas M; Daemen, Joost; Costa, Francesco; Bergoli, Luis Carlos; Ligthart, Jurgen M R; Regar, Evelyn; de Jaegere, Peter P; Zijlstra, Felix; van Geuns, Robert Jan; Diletti, Roberto

    2016-10-15

    Limited data are available on bioresorbable vascular scaffolds (BVS) performance in bifurcations lesions and on the impact of BVS wider struts on side-branch impairment. Patients with at least one coronary bifurcation lesion involving a side-branch ≥2mm in diameter and treated with at least one BVS were examined. Procedural and angiographic data were collected and a dedicated methodology for off-line quantitative coronary angiography (QCA) in bifurcation was applied (eleven-segment model), to assess side-branch impairment occurring any time during the procedure. Two- and three-dimensional QCA were used. Optical coherence tomography (OCT) analysis was performed in a subgroup of patients and long-term clinical outcomes reported. A total of 102 patients with 107 lesions, were evaluated. Device- and procedural-successes were 99.1% and 94.3%, respectively. Side-branch impairment occurring any time during the procedure was reported in 13 bifurcations (12.1%) and at the end of the procedure in 6.5%. Side-branch minimal lumen diameter (Pre: 1.45±0.41mm vs Final: 1.48±0.42mm, p=0.587) %diameter-stenosis (Pre: 26.93±16.89% vs Final: 27.80±15.57%, p=0.904) and minimal lumen area (Pre: 1.97±0.89mm(2) vs Final: 2.17±1.09mm(2), p=0.334), were not significantly affected by BVS implantation. Mean malapposed struts at the bifurcation polygon-of-confluence were 0.63±1.11. The results of the present investigation suggest feasibility and relative safety of BVS implantation in coronary bifurcations. BVS wide struts have a low impact on side-branch impairment when considering bifurcations with side-branch diameter≥2mm. Copyright © 2016. Published by Elsevier Ireland Ltd.

  18. Usefulness and Safety of a Guide Catheter Extension System for the Percutaneous Treatment of Complex Coronary Lesions by a Transradial Approach

    PubMed Central

    García-Blas, Sergio; Núñez, Julio; Mainar, Luis; Miñana, Gema; Bonanad, Clara; Racugno, Paolo; Rodríguez, Juan Carlos; Moyano, Patricia; Sanchis, Juan

    2015-01-01

    Objective The aim of this study was to describe our initial experience with the GuideLiner® catheter (Vascular Solutions Inc.) in the transradial treatment of complex lesions. Materials and Methods The clinical, angiographic and procedural data of percutaneous coronary interventions where GuideLiner was used during 2013 were collected. The transradial approach was used in all cases. The indication for its use, efficacy and periprocedural complications were determined. Sixteen consecutive procedures (in 15 patients; 12 males and 3 females) were evaluated. The indication for the use of GuideLiner was a difficulty to advance and properly position a stent through a tortuous and/or calcified artery despite using high-support guide catheters or other useful techniques. Results Of the 16 angiographic procedures, 14 (87.5s%) were successful (stent deployment in 13 cases and a drug-eluting balloon in 1 case). Unsuccessful cases were a chronic total occlusion and a diffusely diseased left anterior descendant artery. A type B dissection of a proximal left circumflex artery was the only periprocedural complication. Conclusion Use of the GuideLiner was an effective and safe technique for the percutaneous treatment of complex coronary lesions in which the adequate progress of angioplasty devices had failed. GuideLiner was particularly helpful when using the transradial approach. Only one minor complication was recorded. PMID:25531292

  19. Usefulness and safety of a guide catheter extension system for the percutaneous treatment of complex coronary lesions by a transradial approach.

    PubMed

    García-Blas, Sergio; Núñez, Julio; Mainar, Luis; Miñana, Gema; Bonanad, Clara; Racugno, Paolo; Rodríguez, Juan Carlos; Moyano, Patricia; Sanchis, Juan

    2015-01-01

    The aim of this study was to describe our initial experience with the GuideLiner® catheter (Vascular Solutions Inc.) in the transradial treatment of complex lesions. The clinical, angiographic and procedural data of percutaneous coronary interventions where GuideLiner was used during 2013 were collected. The transradial approach was used in all cases. The indication for its use, efficacy and periprocedural complications were determined. Sixteen consecutive procedures (in 15 patients; 12 males and 3 females) were evaluated. The indication for the use of GuideLiner was a difficulty to advance and properly position a stent through a tortuous and/or calcified artery despite using high-support guide catheters or other useful techniques. Of the 16 angiographic procedures, 14 (87.5%) were successful (stent deployment in 13 cases and a drug-eluting balloon in 1 case). Unsuccessful cases were a chronic total occlusion and a diffusely diseased left anterior descendant artery. A type B dissection of a proximal left circumflex artery was the only periprocedural complication. Use of the GuideLiner was an effective and safe technique for the percutaneous treatment of complex coronary lesions in which the adequate progress of angioplasty devices had failed. GuideLiner was particularly helpful when using the transradial approach. Only one minor complication was recorded. © 2014 S. Karger AG, Basel.

  20. The Effect of PAI-1 4G/5G Polymorphism and Clinical Factors on Coronary Artery Occlusion in Myocardial Infarction.

    PubMed

    Parpugga, Tajinder Kumar; Tatarunas, Vacis; Skipskis, Vilius; Kupstyte, Nora; Zaliaduonyte-Peksiene, Diana; Lesauskaite, Vaiva

    2015-01-01

    Data on the impact of PAI-1-675 4G/5G genotype for fibrinolysis during myocardial infarction are inconsistent. The aim of our study was to evaluate the association of clinical and genetic (PAI-1-675 4G/5G polymorphism) factors with coronary artery occlusion in patients with myocardial infarction. PAI-1-675 4G/5G detection was achieved by using Sanger sequencing in a sample of patients hospitalized for stent implantation due to myocardial infarction. We categorized the patients into two groups: patients with coronary artery occlusion and patients without coronary artery occlusion according to angiographic evaluation. We identified n = 122 (32.4%) 4G/4G, n = 186 (49.5%) 4G/5G, and n = 68 (18.1%) 5G/5G PAI-1 genotype carriers. Univariate and multivariate analysis showed that only the 4G/5G genotype was associated with coronary artery occlusion (OR: 1.656 and 95% CI: 1.009-2.718, p = 0.046). Our results showed that carriers of PAI-1 4G/5G genotype with myocardial infarction have increased odds of coronary artery occlusion more than 1.6 times in comparison to the carriers of homozygous genotypes.

  1. The Effect of PAI-1 4G/5G Polymorphism and Clinical Factors on Coronary Artery Occlusion in Myocardial Infarction

    PubMed Central

    Parpugga, Tajinder Kumar; Tatarunas, Vacis; Skipskis, Vilius; Kupstyte, Nora; Zaliaduonyte-Peksiene, Diana; Lesauskaite, Vaiva

    2015-01-01

    Objective. Data on the impact of PAI-1-675 4G/5G genotype for fibrinolysis during myocardial infarction are inconsistent. The aim of our study was to evaluate the association of clinical and genetic (PAI-1-675 4G/5G polymorphism) factors with coronary artery occlusion in patients with myocardial infarction. Materials and Methods. PAI-1-675 4G/5G detection was achieved by using Sanger sequencing in a sample of patients hospitalized for stent implantation due to myocardial infarction. We categorized the patients into two groups: patients with coronary artery occlusion and patients without coronary artery occlusion according to angiographic evaluation. Results. We identified n = 122 (32.4%) 4G/4G, n = 186 (49.5%) 4G/5G, and n = 68 (18.1%) 5G/5G PAI-1 genotype carriers. Univariate and multivariate analysis showed that only the 4G/5G genotype was associated with coronary artery occlusion (OR: 1.656 and 95% CI: 1.009–2.718, p = 0.046). Conclusions. Our results showed that carriers of PAI-1 4G/5G genotype with myocardial infarction have increased odds of coronary artery occlusion more than 1.6 times in comparison to the carriers of homozygous genotypes. PMID:26273123

  2. Comparison of Physician Visual Assessment With Quantitative Coronary Angiography in Assessment of Stenosis Severity in China.

    PubMed

    Zhang, Haibo; Mu, Lin; Hu, Shuang; Nallamothu, Brahmajee K; Lansky, Alexandra J; Xu, Bo; Bouras, Georgios; Cohen, David J; Spertus, John A; Masoudi, Frederick A; Curtis, Jeptha P; Gao, Runlin; Ge, Junbo; Yang, Yuejin; Li, Jing; Li, Xi; Zheng, Xin; Li, Yetong; Krumholz, Harlan M; Jiang, Lixin

    2018-02-01

    Although physician visual assessment (PVA) of stenosis severity is a standard clinical practice to support decisions for coronary revascularization, there are concerns about its accuracy. To compare PVA with quantitative coronary angiography (QCA) as a means of assessing stenosis severity among patients undergoing percutaneous coronary intervention (PCI) in China. A cross-sectional study (2012-2013) of a random subset of 1295 patients from the China Patient-centered Evaluative Assessment of Cardiac Events (PEACE) Prospective PCI Study was carried out. The PEACE Prospective PCI study recruited a consecutive sample of patients undergoing PCI at 35 hospitals in 18 provinces of China. The coronary angiograms of this subset of participants were reviewed using QCA by 2 independent core laboratories blinded to PVA readings. Differences between PVA and QCA assessments of stenosis severity for lesions for which PCI was performed and variation of these differences among hospitals and physicians, stratified by the diagnosis of acute myocardial infarction (AMI). In patients without AMI, the mean (SD) age was 62 (10) years, and 217 (31.5%) were women; in patients with AMI, the mean (SD) age was 60 (11) years, and 153 (25.2%) were women. The mean (SD) percent diameter stenosis by PVA was 16.0% (11.5%) greater than that by QCA in patients without AMI and 10.2% (12.3%) in those with AMI (P < .001 for both comparisons). In patients without AMI, of 837 lesions with 70% or more stenosis by PVA, 427 (50.6%) were less than 70% by QCA; in patients with AMI, similar patterns were observed to a lesser extent. Among patients without AMI, only 4 (0.47%) lesions were additionally assessed with fractional flow reserve. Among 30 hospitals, the difference between PVA and QCA readings of stenosis severity varied from 7.6% (95% CI, 0.4%-14.7%) to 21.3% (95% CI, 17.1%-24.9%) among non-AMI patients. Across 57 physicians, this difference varied from 6.9% (95% CI, -1.4%-15.3%) to 26.4% (95% CI

  3. Coronary artery dimensions in normal Indians.

    PubMed

    Raut, Barendra Kumar; Patil, Vijaysinh Namdeo; Cherian, George

    Diameter of coronary artery is an important predictor of outcome after percutaneous coronary interventions and coronary artery bypass graft surgery. There is very limited data available about coronary artery dimensions in an Indian population. To study the normal dimensions of the coronary artery segments in Indians without coronary artery disease by using quantitative coronary angiography and also to compare the dimensions in Indians with Western. 229 patients who have undergone coronary angiography with entirely normal coronary angiogram were included in our study. This study showed the diameter of vessels in males and females when taken together the left main was larger in size followed by proximal LAD, proximal RCA & proximal LCX respectively (4.08±0.44mm, 3.27±0.23mm, 3.20±0.37mm, 2.97±0.37mm).When the vessel diameter was indexed to body surface area there was no statistical difference between male and female (p value>0.05). The computed value of proximal coronary artery diameter unadjusted for individual body surface area, when compared to Caucasians showed that Caucasians have larger coronary artery dimensions than Indians. But when the proximal vessel diameter was indexed to body surface area there was no statistical significant difference between Indians and Caucasians (p value>0.05). We found that coronary artery size when indexed to body surface area is not statistically different in Indian males and females and compared to Caucasians. However with a smaller body habitus Indians have smaller coronary arteries. Copyright © 2017. Published by Elsevier B.V.

  4. Coronary artery disease in Bangladesh: A review

    PubMed Central

    Islam, A.K.M. Monwarul; Majumder, A.A.S.

    2013-01-01

    Coronary artery disease (CAD) is an increasingly important medical and public health problem, and is the leading cause of mortality in Bangladesh. Like other South Asians, Bangladeshis are unduly prone to develop CAD, which is often premature in onset, follows a rapidly progressive course and angiographically more severe. The underlying pathophysiology is poorly understood. Genetic predisposition, high prevalence of metabolic syndrome and conventional risk factors play important role. Lifestyle related factors, including poor dietary habits, excess saturated and trans fat, high salt intake, and low-level physical activity may be important as well. Some novel risk factors, including hypovitaminosis D, arsenic contamination in water and food-stuff, particulate matter air pollution may play unique role. At the advent of the new millennium, we know little about our real situation. Largescale epidemiological, genetic and clinical researches are needed to explore the different aspects of CAD in Bangladesh. PMID:23993003

  5. Periodontitis in coronary heart disease patients: strong association between bleeding on probing and systemic biomarkers.

    PubMed

    Bokhari, Syed Akhtar H; Khan, Ayyaz A; Butt, Arshad K; Hanif, Mohammad; Izhar, Mateen; Tatakis, Dimitris N; Ashfaq, Mohammad

    2014-11-01

    Few studies have examined the relationship of individual periodontal parameters with individual systemic biomarkers. This study assessed the possible association between specific clinical parameters of periodontitis and systemic biomarkers of coronary heart disease risk in coronary heart disease patients with periodontitis. Angiographically proven coronary heart disease patients with periodontitis (n = 317), aged >30 years and without other systemic illness were examined. Periodontal clinical parameters of bleeding on probing (BOP), probing depth (PD), and clinical attachment level (CAL) and systemic levels of high-sensitivity C-reactive protein (CRP), fibrinogen (FIB) and white blood cells (WBC) were noted and analyzed to identify associations through linear and stepwise multiple regression analyses. Unadjusted linear regression showed significant associations between periodontal and systemic parameters; the strongest association (r = 0.629; p < 0.001) was found between BOP and CRP levels, the periodontal and systemic inflammation marker, respectively. Stepwise regression analysis models revealed that BOP was a predictor of systemic CRP levels (p < 0.0001). BOP was the only periodontal parameter significantly associated with each systemic parameter (CRP, FIB, and WBC). In coronary heart disease patients with periodontitis, BOP is strongly associated with systemic CRP levels; this association possibly reflects the potential significance of the local periodontal inflammatory burden for systemic inflammation. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. [Clinical implications and angiographic and electrocardiographic correlation of ST segment elevation in leads V7-V9 in patients with ST elevation myocardial infarction].

    PubMed

    Adawi, Khaled; Atar, Shaul

    2008-07-01

    The clinical significance and clinical characteristics of patients with myocardial infarction involving the posterior wall of the left ventricle is not well-defined. The angiographic findings and their correlation with the eletrocardiographic (ECG) findings may be of high therapeutic importance. We retrospectively studied consecutive patients with ST elevation myocardial infarction on the admission ECG to the intensive cardiac care. We studied the clinical and demographic characteristics, the clinical course in-hospital and the clinical outcome (including infarct size, congestive heart failure and significant mitral insufficiency). All patients underwent coronary angiography during the index admission. We correlated the ECG findings on admission to the angiographic findings. We studied 198 patients with mean age of 57 +/- 12 years (range 30-88 years), 158 men (79.8%) and 40 women (20.2%). Myocardial infarction involving the inferior wall was noted in 119 patients, of whom 68 had inferior wall myocardial infarction only, and 51 had inferior and lateral wall involvement (leads I, AVL and/or V5-V6). Only 4 patients (2%) had ST elevation in leads V7-V9 only. The left ventricular ejection fraction was lowest in patients with anterior wall myocardial infarction (41% +/- 6) compared to myocardial infarction with the posterior wall involved (44% +/- 8) or myocardial infarction with the inferior wall only (54% +/- 6) (p = 0.023). The largest infarct size by peak creatine phosphokinase was found in the inferoposterior myocardial infarction group, significantly larger from inferior infarction only, and similar to that of anterior myocardial infarction. The incidence of congestive heart failure was slightly more in anterior myocardial infarction; however, significant mitral valve insufficiency was higher in patients with posterior wall involvement, yet with no statistical significance. The infarct related artery causing posterior myocardial infarction was significantly more

  7. The role of percutaneous transluminal coronary angioplasty in heart transplant recipients.

    PubMed

    Schnetzler, B; Drobinski, G; Dorent, R; Camproux, A C; Ghossoub, J; Thomas, D; Gandjbakhch, I

    2000-06-01

    Review the acute and late results of percutaneous transluminal coronary angioplasty (PTCA) in heart transplant recipients and examine the factors predictive of restenosis. Coronary graft disease (CGD) is the main factor responsible for late graft loss. Medical treatment, surgical revascularization, or retransplantation gives only suboptimal results in this regard. Therefore, PTCA has been attempted in this situation. More than 332 heart transplantations in our institution have been performed since 1992, the date of the first PTCA in our patients. We are currently in charge of 450 patients. All the characteristics, procedure-related information, and clinical outcome of patients needing PTCA were assessed by review of each patient's clinical records. All coronary angiograms were reviewed by an independent cardiologist. Since 1992, 53 coronary sites have been dilated in the course of 39 procedures in 29 patients. Indication for PTCA was asymptomatic angiographic coronary graft disease in 35 sites (64.8%), angina in 9 (16.6%), silent ischemia in 2 (3.7%), acute myocardial infarction in 1 (1.8%), and CHF in 7 (12.9%). Primary success (< 50% residual stenosis) was obtained in 50 (94.3%) of 53 lesions. No periprocedural death occurred. Procedural complications were 1 transient acute renal failure and 1 persistent bleeding at the puncture site. Six months restenosis rate (defined as percent stenosis > 50%) was 32.5% (14/43). Mean follow-up was 1.27 year +/- 1.2 (SD). Five deaths (17. 2%) occurred in follow-up and were all in relation to coronary graft disease. Mean time separating PTCA from death was 0.9 year +/- 1.3 (SD). We also sought to look at factors predictive of restenosis. By multivariate analysis, a positive recipient's serology for cytomegalovirus (CMV) before the graft was the only factor found protective against restenosis (odds ratio 22.4; confidence interval 1.1 to 443.4). PTCA in heart transplant recipients allows a high level of primary success with a low

  8. Inverse relationship between body mass index and coronary artery calcification in patients with clinically significant coronary lesions.

    PubMed

    Kovacic, Jason C; Lee, Paul; Baber, Usman; Karajgikar, Rucha; Evrard, Solene M; Moreno, Pedro; Mehran, Roxana; Fuster, Valentin; Dangas, George; Sharma, Samin K; Kini, Annapoorna S

    2012-03-01

    Mounting data support a 'calcification paradox', whereby reduced bone mineral density is associated with increased vascular calcification. Furthermore, reduced bone mineral density is prevalent in older persons with lower body mass index (BMI). Therefore, although BMI and coronary artery calcification (CAC) exhibit a positive relationship in younger persons, it is predicted that in older persons and/or those at risk for osteoporosis, an inverse relationship between BMI and CAC may apply. We sought to explore this hypothesis in a large group of patients with coronary artery disease undergoing percutaneous coronary intervention (PCI). We accessed our single-center registry for 07/01/1999 to 06/30/2009, extracting data on all patients that underwent PCI. To minimize bias we excluded those at the extremes of age or BMI and non-Black/Hispanic/Caucasians, leaving 9993 study subjects (age 66.6±9.9 years). Index lesion calcification (ILC) was analyzed with respect to BMI. Comparing index lesions with no angiographic calcification to those with the most severe, mean BMI decreased by 1.11 kgm(-2); a reduction of 3.9% (P<0.0001). By multivariable modeling, BMI was an independent inverse predictor of moderate-severe ILC (m-sILC; odds ratio [OR] 0.967, 95% CI 0.953-0.980, P<0.0001). Additional fully adjusted models identified that, compared to those with normal BMI, obese patients had an OR of 0.702 for m-sILC (95% CI 0.596-0.827, P<0.0001). In a large group of PCI patients, we identified an inverse correlation between BMI and index lesion calcification. These associations are consistent with established paradigms and suggest a complex interrelationship between BMI, body size and vascular calcification. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  9. 21 CFR 892.1600 - Angiographic x-ray system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Angiographic x-ray system. 892.1600 Section 892.1600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... device may include signal analysis and display equipment, patient and equipment supports, component parts...

  10. 21 CFR 892.1600 - Angiographic x-ray system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Angiographic x-ray system. 892.1600 Section 892.1600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... device may include signal analysis and display equipment, patient and equipment supports, component parts...

  11. 21 CFR 892.1600 - Angiographic x-ray system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Angiographic x-ray system. 892.1600 Section 892.1600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... device may include signal analysis and display equipment, patient and equipment supports, component parts...

  12. 21 CFR 892.1600 - Angiographic x-ray system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Angiographic x-ray system. 892.1600 Section 892.1600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... device may include signal analysis and display equipment, patient and equipment supports, component parts...

  13. 21 CFR 892.1600 - Angiographic x-ray system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Angiographic x-ray system. 892.1600 Section 892.1600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... device may include signal analysis and display equipment, patient and equipment supports, component parts...

  14. Quantitative evaluation of capillaroscopic microvascular changes in patients with established coronary heart disease.

    PubMed

    Sanchez-Garcia, M Esther; Ramirez-Lara, Irene; Gomez-Delgado, Francisco; Yubero-Serrano, Elena M; Leon-Acuña, Ana; Marin, Carmen; Alcala-Diaz, Juan F; Camargo, Antonio; Lopez-Moreno, Javier; Perez-Martinez, Pablo; Tinahones, Francisco José; Ordovas, Jose M; Caballero, Javier; Blanco-Molina, Angeles; Lopez-Miranda, Jose; Delgado-Lista, Javier

    2018-02-23

    Microcirculation disturbances have been associated to most of the cardiovascular risk factors as well as to multiple inflammatory diseases. However, whether these abnormalities are specifically augmented in patients with coronary heart disease is still unknown. We aimed to evaluate if there is a relationship between the presence of coronary heart disease and the existence of functional and structural capillary abnormalities evaluated in the cutaneous microcirculation by videocapillaroscopy. Two matched samples of 30 participants with and without coronary heart disease but with similar clinical and anthropometric characteristics were evaluated by videocapillaroscopy at the dorsal skin of the third finger of the non-dominant hand. We calculated basal capillary density as well as capillary density after a period of arterial and venous occlusion in order to evaluate functionality and maximum capillary density. We also measured capillary recruitment. Microvascular capillary density at rest was significantly lower in patients suffering from coronary heart disease than in controls. This fact was also found after dynamic tests (arterial and venous occlusion), suggesting functional impairments. Capillary recruitment of the samples was not different in our sample. In our study, patients with coronary heart disease exhibit functional and structural microvascular disturbances. Although this is a very preliminary study, these findings open the door for further studying the microvascular functionality in coronary patients and how it relates to the response to treatment and/or the prognosis of the disease. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  15. HOMA-IR is associated with significant angiographic coronary artery disease in non-diabetic, non-obese individuals: a cross-sectional study.

    PubMed

    Mossmann, Márcio; Wainstein, Marco V; Gonçalves, Sandro C; Wainstein, Rodrigo V; Gravina, Gabriela L; Sangalli, Marlei; Veadrigo, Francine; Matte, Roselene; Reich, Rejane; Costa, Fernanda G; Bertoluci, Marcello C

    2015-01-01

    Insulin resistance is a major component of metabolic syndrome, type 2 Diabetes Mellitus (T2DM) and coronary artery disease (CAD). Although important in T2DM, its role as a predictor of CAD in non-diabetic patients is less studied. In the present study, we aimed to evaluate the association of HOMA-IR with significant CAD, determined by coronary angiography in non-obese, non-T2DM patients. We also evaluate the association between 3 oral glucose tolerance test (OGTT) based insulin sensitivity indexes (Matsuda, STUMVOLL-ISI and OGIS) and CAD. We conducted a cross-sectional study with 54 non-obese, non-diabetic individuals referred for coronary angiography due to suspected CAD. CAD was classified as the "anatomic burden score" corresponding to any stenosis equal or larger than 50 % in diameter on the coronary distribution. Patients without lesions were included in No-CAD group. Patients with at least 1 lesion were included in the CAD group. A 75 g oral glucose tolerance test (OGTT) with measurements of plasma glucose and serum insulin at 0, 30, 60, 90 and 120 min was obtained to calculate insulin sensitivity parameters. HOMA-IR results were ranked and patients were also categorized into insulin resistant (IR) or non-insulin resistant (NIR) if they were respectively above or below the 75th percentile (HOMA-IR > 4.21). The insulin sensitivity tests results were also divided into IR and NIR, respectively below and above each 25th percentile. Chi square was used to study association. Poisson Regression Model was used to compare prevalence ratios between categorized CAD and IR groups. Fifty-four patients were included in the study. There were 26 patients (48 %) with significant CAD. The presence of clinically significant CAD was significant associated with HOMA-IR above p75 (Chi square 4.103, p = 0.0428) and 71 % of patients with HOMA-IR above p75 had significant CAD. Subjects with CAD had increased prevalence ratio of HOMA-IR above p75 compared to subjects without

  16. Comparison of left anterior descending coronary artery hemodynamics before and after angioplasty.

    PubMed

    Ramaswamy, S D; Vigmostad, S C; Wahle, A; Lai, Y G; Olszewski, M E; Braddy, K C; Brennan, T M H; Rossen, J D; Sonka, M; Chandran, K B

    2006-02-01

    Coronary artery disease (CAD) is characterized by the progression of atherosclerosis, a complex pathological process involving the initiation, deposition, development, and breakdown of the plaque. The blood flow mechanics in arteries play a critical role in the targeted locations and progression of atherosclerotic plaque. In coronary arteries with motion during the cardiac contraction and relaxation, the hemodynamic flow field is substantially different from the other arterial sites with predilection of atherosclerosis. In this study, our efforts focused on the effects of arterial motion and local geometry on the hemodynamics of a left anterior descending (LAD) coronary artery before and after clinical intervention to treat the disease. Three-dimensional (3D) arterial segments were reconstructed at 10 phases of the cardiac cycle for both pre- and postintervention based on the fusion of intravascular ultrasound (IVUS) and biplane angiographic images. An arbitrary Lagrangian-Eulerian formulation was used for the computational fluid dynamic analysis. The measured arterial translation was observed to be larger during systole after intervention and more out-of-plane motion was observed before intervention, indicating substantial alterations in the cardiac contraction after angioplasty. The time averaged axial wall shear stress ranged from -0.2 to 9.5 Pa before intervention compared to -0.02 to 3.53 Pa after intervention. Substantial oscillatory shear stress was present in the preintervention flow dynamics compared to that in the postintervention case.

  17. Development of a model of the coronary arterial tree for the 4D XCAT phantom

    NASA Astrophysics Data System (ADS)

    Fung, George S. K.; Segars, W. Paul; Gullberg, Grant T.; Tsui, Benjamin M. W.

    2011-09-01

    A detailed three-dimensional (3D) model of the coronary artery tree with cardiac motion has great potential for applications in a wide variety of medical imaging research areas. In this work, we first developed a computer-generated 3D model of the coronary arterial tree for the heart in the extended cardiac-torso (XCAT) phantom, thereby creating a realistic computer model of the human anatomy. The coronary arterial tree model was based on two datasets: (1) a gated cardiac dual-source computed tomography (CT) angiographic dataset obtained from a normal human subject and (2) statistical morphometric data of porcine hearts. The initial proximal segments of the vasculature and the anatomical details of the boundaries of the ventricles were defined by segmenting the CT data. An iterative rule-based generation method was developed and applied to extend the coronary arterial tree beyond the initial proximal segments. The algorithm was governed by three factors: (1) statistical morphometric measurements of the connectivity, lengths and diameters of the arterial segments; (2) avoidance forces from other vessel segments and the boundaries of the myocardium, and (3) optimality principles which minimize the drag force at the bifurcations of the generated tree. Using this algorithm, the 3D computational model of the largest six orders of the coronary arterial tree was generated, which spread across the myocardium of the left and right ventricles. The 3D coronary arterial tree model was then extended to 4D to simulate different cardiac phases by deforming the original 3D model according to the motion vector map of the 4D cardiac model of the XCAT phantom at the corresponding phases. As a result, a detailed and realistic 4D model of the coronary arterial tree was developed for the XCAT phantom by imposing constraints of anatomical and physiological characteristics of the coronary vasculature. This new 4D coronary artery tree model provides a unique simulation tool that can be

  18. Renal artery origins: best angiographic projection angles.

    PubMed

    Verschuyl, E J; Kaatee, R; Beek, F J; Patel, N H; Fontaine, A B; Daly, C P; Coldwell, D M; Bush, W H; Mali, W P

    1997-10-01

    To determine the best projection angles for imaging the renal artery origins in profile. A mathematical model of the anatomy at the renal artery origins in the transverse plane was used to analyze the amount of aortic lumen that projects over the renal artery origins at various projection angles. Computed tomographic (CT) angiographic data about the location of 400 renal artery origins in 200 patients were statistically analyzed. In patients with an abdominal aortic diameter no larger than 3.0 cm, approximately 0.5 mm of the proximal part of the renal artery and origin may be hidden from view if there is a projection error of +/-10 degrees from the ideal image. A combination of anteroposterior and 20 degrees and 40 degrees left anterior oblique projections resulted in a 92% yield of images that adequately profiled the renal artery origins. Right anterior oblique projections resulted in the least useful images. An error in projection angle of +/-10 degrees is acceptable for angiographic imaging of the renal artery origins. Patients sex, site of interest (left or right artery), and local diameter of the abdominal aorta are important factors to consider.

  19. Circulating endothelial progenitor cells are inversely correlated with in-stent restenosis in patients with non-ST-segment elevation acute coronary syndromes treated with EPC-capture stents (JACK-EPC trial).

    PubMed

    Wojakowski, W; Pyrlik, A; Król, M; Buszman, P; Ochała, A; Milewski, K; Smolka, G; Kawecki, D; Rudnik, A; Pawłowski, T; Jadczyk, T; Wyderka, R; Cybulski, W; Dworowy, S; Tendera, M

    2013-06-01

    Aim of the study was to evaluate the association between circulating endothelial progenitor cells (EPCs) and angiographic outcomes after implantation of GenousTM stent in patients with non-ST-segment elevation acute coronary syndromes (ACS) (NSTE-ACS) undergoing urgent percutaneous coronary intervention (PCI). Sixty patients treated with EPC-capture stent (N.=30) or bare metal stents (BMS) (N.=30) receiving 80 mg atorvastatin and dual antiplatelet therapy (DAT) for 12 months. Restenosis was assessed after 6 months by quantitative coronary angiography (QCA) and major acute coronary events (MACE) evaluated after 6 and 12 months. de novo lesion >70% in native vessel, diameter 2.5-4 mm, lesion length <30 mm. diabetes, previous revascularization, significant left main stenosis, chronic total occlusions (CTO) and multivessel disease. Majority of patients in EPC-capture stent and BMS groups presented with NSTEMI (73.3% and 70%, respectively). Mean stent length was 20.1±8 and 19.9±10 mm, diameter 3±0.97 and 3.1±0.88 mm in respective groups. The binary restenosis was significantly lower in GenousTM (13 vs. 26.6%, P=0.04). Risk of MACE after 6 and 12 months were comparable in both groups. There was no stent thrombosis. Numbers of circulating EPCs were significantly approximately 2-fold higher during the ACS than after 6 months. Mobilization of EPCs during acute ischemia was significantly lower in patients who developed restenosis after 6 months (3 vs. 4.5 cells/μL, P=0.002) and it was negatively correlated with late-loss after 6 months (R=-0.42; P<0.03). Use of GenousTM stents in NSTE-ACS is associated with lower restenosis rate than BMS at 6 months. There was no ST through 1 year. The number of circulating EPCs is inversely correlated with in-stent late loss (LL).

  20. Myocardial Ischemia During Mental Stress: Role of Coronary Artery Disease Burden and Vasomotion

    PubMed Central

    Ramadan, Ronnie; Sheps, David; Esteves, Fabio; Maziar Zafari, A.; Douglas Bremner, J.; Vaccarino, Viola; Quyyumi, Arshed A.

    2013-01-01

    Background Mental stress–induced myocardial ischemia (MSIMI) is associated with adverse prognosis in patients with coronary artery disease (CAD), yet the mechanisms underlying this phenomenon remain unclear. We hypothesized that compared with exercise/pharmacological stress–induced myocardial ischemia (PSIMI) that is secondary to the atherosclerotic burden of CAD, MSIMI is primarily due to vasomotor changes. Methods and Results Patients with angiographically documented CAD underwent 99mTc‐sestamibi myocardial perfusion imaging at rest and following both mental and physical stress testing, performed on separate days. The severity and extent of CAD were quantified using the Gensini and Sullivan scores. Peripheral arterial tonometry (Itamar Inc) was used to assess the digital microvascular tone during mental stress as a ratio of pulse wave amplitude during speech compared with baseline. Measurements were made in a discovery sample (n=225) and verified in a replication sample (n=159). In the pooled (n=384) sample, CAD severity and extent scores were not significantly different between those with and without MSIMI, whereas they were greater in those with compared with those without PSIMI (P<0.04 for all). The peripheral arterial tonometry ratio was lower in those with compared with those without MSIMI (0.55±0.36 versus 0.76±0.52, P=0.009). In a multivariable analysis, the peripheral arterial tonometry ratio was the only independent predictor of MSIMI (P=0.009), whereas angiographic severity and extent of CAD independently predicted PSIMI. Conclusions The degree of digital microvascular constriction, and not the angiographic burden of CAD, is associated with MSIMI. Varying causes of MSIMI compared with PSIMI may require different therapeutic interventions that require further study. PMID:24145741

  1. Genetic variants on apolipoprotein gene cluster influence triglycerides with a risk of coronary artery disease among Indians.

    PubMed

    AshokKumar, Manickaraj; Subhashini, Navaneethan Gnana Veera; SaiBabu, Ramineni; Ramesh, Arabandi; Cherian, Kotturathu Mammen; Emmanuel, Cyril

    2010-01-01

    Apolipoprotein C3 and apolipoprotien A5 are proteins coded from the APOA1/C3/A4/A5 gene cluster. Sst I polymorphism on apolipoprotein C3 and -1131C polymorphism of apolipoprotien A5 are key variants involved in triglyceride metabolism and cause a significant cardio-metabolic risk. Here, we have evaluated these two variants for their roles in coronary artery disease in patients of the Indian population. The apolipoprotein gene cluster variants were analysed in 416 angiographically determined coronary artery disease patients and matched 416 controls using polymerase chain reaction-restriction fragment length polymorphism. The characteristics of the study subjects were analyzed statistically for their association with the polymorphisms. The alleles were combined as haplotypes and their combined risks were evaluated. The minor allele genotypes of both apolipoprotein C3 (S2) and apolipoprotien A5 (C) had a significant risk for coronary artery disease. The S2 allele genotyped patients had a significantly increased triglyceride level (P < 0.001) and increased triglycerides were observed among both patient and control CC genotype carriers. We identified the haplotype S2/C with a significant increased risk (P < 0.001) to coronary artery disease with increased levels of circulating triglycerides compared to other haplotypes in patients. We conclude that the variants on apolipoprotein C3 and apolipoprotien A5 modulate serum triglyceride levels and increase the risk of coronary artery disease.

  2. Haemodynamic dose-response effects of intravenous nisoldipine in coronary artery disease.

    PubMed Central

    Silke, B; Frais, M A; Muller, P; Verma, S P; Reynolds, G; Taylor, S H

    1985-01-01

    The circulatory consequences of slow-calcium channel blockade with a new dihydropyridine nisoldipine were evaluated at rest and during exercise-induced angina in 16 patients with angiographically proven coronary artery disease. In 10 patients resting cardiac stroke output (thermodilution) and pulmonary artery occluded pressure were determined following four intravenous nisoldipine injections (cumulative dosage of 1, 2, 4 and 8 micrograms kg-1). The exercise effects of nisoldipine were evaluated by comparing the effects of the 8 micrograms kg-1 cumulative dosage with a control exercise period at the same workload. At rest nisoldipine reduced systemic vascular resistance and mean arterial pressure, and increased heart rate, cardiac and stroke volume indices. During 4 min supine-bicycle exercise nisoldipine reduced systemic mean arterial pressure and vascular resistance; this resulted in augmented cardiac and stroke volume indices at an unchanged pulmonary artery occluded pressure. In six additional patients rest and exercise ejection fractions were measured using a nonimaging nuclear probe. Nisoldipine (4 micrograms kg-1) resulted in a small trend to increase left ventricular rest and exercise ejection fraction. These data demonstrated improved rest and exercise cardiac performance following nisoldipine in patients with severe coronary artery disease. PMID:4091998

  3. Unique Angiographic Appearances of Moyamoya Disease Detected with 3-Dimensional Rotational Digital Subtraction Angiography Imaging Showing the Hemodynamic Status.

    PubMed

    Karakama, Jun; Nariai, Tadashi; Hara, Shoko; Hayashi, Shihori; Sumita, Kazutaka; Inaji, Motoki; Tanaka, Yoji; Wagatsuma, Kei; Ishii, Kenji; Nemoto, Shigeru; Maehara, Taketoshi

    2018-04-10

    The aim of this study was to identify the unique morphological arterial features in patients with moyamoya disease on 3-dimensional rotational digital subtraction angiography. One hundred seven hemispheres of 58 consecutive patients with moyamoya disease that were analyzed with fused 3-dimensional images of internal carotid angiograms and vertebral angiograms that were marked with different colors were reviewed. Angiographic findings in the posterior watershed area were classified, and the utility of the classification was analyzed by comparing it with clinical presentations and quantitative hemodynamic parameters obtained with positron emission tomography. Two unique angiographic appearances were identified. A vacant vessel appearance (no arterial inflow despite absence of cortical infarction) was observed mostly in transient ischemic attack hemispheres. In hemispheres with a vacant vessel appearance, cerebral blood flow was decreased, cerebral blood volume was increased, and mean transit time was prolonged significantly (P = .00017, P = .0061, and P = .00026, respectively). A cocktail vessel appearance (mixture of carotid and vertebral arterial flow) was most commonly observed in asymptomatic cases, as well as in ischemic hemispheres. Cerebral blood volume increased and mean transit time was prolonged significantly (P = .036 and P = .014, respectively) in hemispheres with a cocktail vessel appearance. The trend of progression in hemodynamic severity in the order of normal appearance, cocktail vessel appearance, and vacant vessel appearance in the watershed area was statistically significant. Fused 3-dimensional digital subtraction angiography demonstrated unique angiographic features in the watershed area, and this represented the degree of cerebral hemodynamic impairment in moyamoya disease. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  4. The ethnicity-specific association of biomarkers with the angiographic severity of coronary artery disease.

    PubMed

    Gijsberts, C M; Seneviratna, A; Bank, I E M; den Ruijter, H M; Asselbergs, F W; Agostoni, P; Remijn, J A; Pasterkamp, G; Kiat, H C; Roest, M; Richards, A M; Chan, M Y; de Kleijn, D P V; Hoefer, I E

    2016-03-01

    Risk factor burden and clinical characteristics of patients with coronary artery disease (CAD) differ among ethnic groups. We related biomarkers to CAD severity in Caucasians, Chinese, Indians and Malays. In the Dutch-Singaporean UNICORN coronary angiography cohort (n = 2033) we compared levels of five cardiovascular biomarkers: N-terminal pro-brain natriuretic peptide (NTproBNP), high-sensitivity C-reactive protein (hsCRP), cystatin C (CysC), myeloperoxidase (MPO) and high-sensitivity troponin I (hsTnI). We assessed ethnicity-specific associations of biomarkers with CAD severity, quantified by the SYNTAX score. Adjusted for baseline differences, NTproBNP levels were significantly higher in Malays than in Chinese and Caucasians (72.1 vs. 34.4 and 41.1 pmol/l, p < 0.001 and p = 0.005, respectively). MPO levels were higher in Caucasians than in Indians (32.8 vs. 27.2 ng/ml, p = 0.026), hsTnI levels were higher in Malays than in Caucasians and Indians (33.3 vs. 16.4 and 17.8 ng/l, p < 0.001 and p = 0.029) and hsTnI levels were higher in Chinese than in Caucasians (23.3 vs. 16.4, p = 0.031). We found modifying effects of ethnicity on the association of biomarkers with SYNTAX score. NTproBNP associated more strongly with the SYNTAX score in Malays than Caucasians (β 0.132 vs. β 0.020 per 100 pmol/l increase in NTproBNP, p = 0.032). For MPO levels the association was stronger in Malays than Caucasians (β 1.146 vs. β 0.016 per 10 ng/ml increase, p = 0.017). Differing biomarker cut-off levels were found for the ethnic groups. When corrected for possible confounders we observe ethnicity-specific differences in biomarker levels. Moreover, biomarkers associated differently with CAD severity, suggesting that ethnicity-specific cut-off values should be considered.

  5. Impact of initial platelet count on baseline angiographic finding and end-points in ST-elevation myocardial infarction referred for primary percutaneous coronary intervention.

    PubMed

    Kaplan, Sahin; Kaplan, Safiye Tuba; Kiris, Abdulkadir; Gedikli, Omer

    2014-01-01

    The baseline platelet count (BPC) in patients with acute ST elevation myocardial infarction (STEMI) may reflect the baseline anjiografic finding and may also predic long-term outcomes after primary percutaneous coronary intervention (PPCI). Available data for the value of BPC in patients with STEMI treated with PPCI are still questionable. Therefore, we sought to determine the prognostic value of BPC for baseline angiographic finding and the impact of BPC on clinical outcomes of patients treating with PPCI. Blood sample for BPC was obtained on admission in 140 consecutive patients undergoing PPCI. Patients were divided 2 groups that group-1 (104 patients): TIMI flow-grade 0 and group-2 (36 patients): TIMI flow-grade 1-3. Follow-up was performed at 1-9 months. Baseline demographics were comparable, but, BPC was significantly higher in group-1 comparing 2 (293.7±59.8x10(9)/L vs. 237.7±50.9x10(9)/L, p<0.0001), pre-procedural lesion length longer in group-1 comparing 2 (13.6±3.6 mm vs. 11.4±3.9 mm, p:0.003). Distal embolization (19.0% vs. 0.0%, p:0.001), slow-flow (15.2% vs. 2.9%, p:0.033) were more common in group-1 and mean maximum troponin-I level (9.1±4.2 μg/L vs. 5.1±3.9 μg/L, p<0.0001) and mean maximum creatinin kinase (2077.6±1378.4 U/L vs. 1163.4±869.7 U/L, p:<0.0001) were higher in group-1. In-hospital and 30-days major cardiac adverse events (MACEs) (16.5% vs. 5.7%), p:0.14) were similarly in both groups, but, at 6-months target vessel revascularization (13.9% vs. 0.0%, p:0.017) and MACEs significantly higher in the group-1 (24.1% vs. 2.9%, p:0.013). A higher BPC without any antithrombotic agent is a strongly predictor of total occlusion of IRA in STEMI treated with PPCI. And a higher BPC associated with poor clinical outcomes at 9-months. Apart from prognostic value, measuring of a BPC on admission may also provide further practical and therapeutic profits.

  6. Impact of initial platelet count on baseline angiographic finding and end-points in ST-elevation myocardial infarction referred for primary percutaneous coronary intervention

    PubMed Central

    Kaplan, Sahin; Kaplan, Safiye Tuba; Kiris, Abdulkadir; Gedikli, Omer

    2014-01-01

    The baseline platelet count (BPC) in patients with acute ST elevation myocardial infarction (STEMI) may reflect the baseline anjiografic finding and may also predic long-term outcomes after primary percutaneous coronary intervention (PPCI). Available data for the value of BPC in patients with STEMI treated with PPCI are still questionable. Therefore, we sought to determine the prognostic value of BPC for baseline angiographic finding and the impact of BPC on clinical outcomes of patients treating with PPCI. Blood sample for BPC was obtained on admission in 140 consecutive patients undergoing PPCI. Patients were divided 2 groups that group-1 (104 patients): TIMI flow-grade 0 and group-2 (36 patients): TIMI flow-grade 1-3. Follow-up was performed at 1-9 months. Baseline demographics were comparable, but, BPC was significantly higher in group-1 comparing 2 (293.7±59.8x109/L vs. 237.7±50.9x109/L, p<0.0001), pre-procedural lesion length longer in group-1 comparing 2 (13.6±3.6 mm vs. 11.4±3.9 mm, p:0.003). Distal embolization (19.0% vs. 0.0%, p:0.001), slow-flow (15.2% vs. 2.9%, p:0.033) were more common in group-1 and mean maximum troponin-I level (9.1±4.2 μg/L vs. 5.1±3.9 μg/L, p<0.0001) and mean maximum creatinin kinase (2077.6±1378.4 U/L vs. 1163.4±869.7 U/L, p:<0.0001) were higher in group-1. In-hospital and 30-days major cardiac adverse events (MACEs) (16.5% vs. 5.7%), p:0.14) were similarly in both groups, but, at 6-months target vessel revascularization (13.9% vs. 0.0%, p:0.017) and MACEs significantly higher in the group-1 (24.1% vs. 2.9%, p:0.013). Conclusion: A higher BPC without any antithrombotic agent is a strongly predictor of total occlusion of IRA in STEMI treated with PPCI. And a higher BPC associated with poor clinical outcomes at 9-months. Apart from prognostic value, measuring of a BPC on admission may also provide further practical and therapeutic profits. PMID:24955183

  7. Ergonovine-induced changes of coronary artery diameter in patients with nonsignificant coronary artery stenosis : relation with lipid profile.

    PubMed

    Nedeljkovic, Milan A; Ostojic, Miodrag C; Beleslin, Branko D; Nedeljkovic, Ivana; Milic, Natasa; Vukcevic, Vladan; Stojkovic, Sinisa; Saponjski, Jovica; Orlic, Dejan; Djordjevic-Dikic, Ana; Stepanovic, Jelena; Giga, Vojislav; Petrasinovic, Zorica; Arandjelovic, Aleksandra; Beleslin, Biljana; Kanjuh, Vladimir

    2007-06-01

    Serum cholesterol is positively associated with the risk of developing coronary heart disease. The aim of this study was to determine the relation between response of coronary arteries to ergonovine provocation and lipid profile in patients with nonsignificant coronary artery disease. 105 patients (46 male, 59 female, mean age 52 +/- 8 years) with chest pain syndrome and nonsignificant coronary artery stenosis (< 50% diameter stenosis) were analyzed. Ergonovine test was performed at the end of diagnostic catheterization. Coronary spasm was defined as total or near total obstruction of the coronary artery. By quantitative coronary arteriography, changes of minimal luminal diameter (MLD) during ergonovine provocation were evaluated. Total cholesterol, LDL and HDL cholesterol, and triglycerides were measured. There was a significant negative correlation between resting MLD and LDL cholesterol (r = -0.215; p = 0.034), and a significant positive correlation between MLD decrease provoked by ergonovine and total cholesterol (r = 0.275; p = 0.006), as well as LDL cholesterol (r = 0.284; p = 0.004), but not for HDL cholesterol and triglycerides (p = NS [not significant]). In patients with nonsignificant coronary artery stenosis evaluated by ergonovine provocation, there was not only a significant negative correlation between MLD and LDL cholesterol, but also a positive correlation between coronary vasoconstriction induced by ergonovine provocation and both total and LDL cholesterol.

  8. Rotational atherectomy before paclitaxel-eluting stent implantation in complex calcified coronary lesions: Two-year clinical outcome of the randomized ROTAXUS trial.

    PubMed

    de Waha, Suzanne; Allali, Abdelhakim; Büttner, Heinz-Joachim; Toelg, Ralph; Geist, Volker; Neumann, Franz-Josef; Khattab, Ahmed A; Richardt, Gert; Abdel-Wahab, Mohamed

    2016-03-01

    In the randomized ROTAXUS trial, routine lesion preparation of complex calcified coronary lesions using rotational atherectomy (RA) prior to paclitaxel-eluting stent implantation did not reduce the primary endpoint of angiographic late lumen loss at 9 months compared to stenting without RA. So far, no long-term data of prospective head-to-head comparisons between both treatment strategies have been reported. ROTAXUS randomly assigned patients with complex calcified coronary lesions to RA followed by stenting (n = 120) or stenting without RA (n = 120). The primary endpoint of the current analysis was the occurrence of major adverse cardiac events (MACE) at 2-year follow-up defined as the composite of death, myocardial infarction, and target vessel revascularization (TVR). At 2 years, MACE occurred in 32 patients in the RA group and 37 patients in the standard therapy group (29.4% vs. 34.3%, P = 0.47). The rates of death (8.3% vs. 7.4%, P = 1.00), myocardial infarction (8.3% vs. 6.5%, P = 0.80), target lesion revascularization (TLR, 13.8% vs. 16.7%, P = 0.58), and TVR (19.3% vs. 22.2%, P = 0.62) were similar in both groups. Despite high rates of initial angiographic success, nearly one third of patients enrolled in ROTAXUS experienced MACE within 2-year follow-up, with no differences between patients treated with or without RA. © 2015 Wiley Periodicals, Inc.

  9. Follow-up of heart transplant recipients with serial echocardiographic coronary flow reserve and dobutamine stress echocardiography to detect cardiac allograft vasculopathy.

    PubMed

    Sade, Leyla Elif; Eroğlu, Serpil; Yüce, Deniz; Bircan, Aslı; Pirat, Bahar; Sezgin, Atilla; Aydınalp, Alp; Müderrisoğlu, Haldun

    2014-05-01

    Implementation of reliable noninvasive testing for screening cardiac allograft vasculopathy (CAV) is of critical importance. The most widely used modality, dobutamine stress echocardiography (DSE), has moderate sensitivity and specificity. The aim of this study was to assess the potential role of serial coronary flow reserve (CFR) assessment together with DSE for predicting CAV. A total of 90 studies were performed prospectively over 5 years in 23 consecutive heart transplant recipients who survived >1 year after transplantation. Assessment of CFR with transthoracic Doppler echocardiography, DSE, coronary angiography, and endomyocardial biopsy was performed annually. Results of CFR assessment and DSE were compared with angiographic findings of CAV. Acute cellular rejections were excluded by endomyocardial biopsies. CAV was detected in 17 of 90 angiograms. Mean CFR was similarly lower in both mild (CAV grade 1) and more severe (CAV grades 2 and 3) vasculopathy, but wall motion score index became higher in parallel with increasing grades of vasculopathy. Any CAV by angiography was detected either simultaneously with or later than CFR impairment, yielding 100% sensitivity for CFR. The combination of CFR and DSE increased the specificity of the latter from 64.3% to 87.2% without compromising sensitivity (77.8%). CFR is very sensitive for detecting CAV and increases the diagnostic accuracy of DSE, raising the potential for patient management tailored to risk modification and to avoid unnecessary angiographic procedures. Copyright © 2014 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

  10. Endometriosis and Risk of Coronary Heart Disease

    PubMed Central

    Mu, Fan; Rich-Edwards, Janet; Rimm, Eric B.; Spiegelman, Donna; Missmer, Stacey A.

    2016-01-01

    Background Endometriosis is a prevalent gynecologic disease associated with systemic chronic inflammation, heightened oxidative stress and atherogenic lipid profile that may increase women's risk for Coronary heart disease (CHD). Methods and Results We examined the prospective association between laparoscopically-confirmed endometriosis and subsequent CHD among 116,430 women in the Nurses’ Health Study II (1989-2009). Participants with a history of heart disease and stroke were excluded. Compared to women without endometriosis, women with laparoscopically-confirmed endometriosis had a higher risk of myocardial infarction (relative risk, 1.52; 95% confidence interval, 1.17-1.98), angiographically-confirmed angina (1.91; 1.59-2.29), coronary artery bypass graft surgery/coronary angioplasty procedure/stent (1.35; 1.08-1.69), or any of these CHD endpoints combined (1.62; 1.39-1.89), independent of potential demographic, anthropometric, family history, reproductive, and lifestyle confounders. Relative risk for the combined CHD endpoint was highest among women age ≤40 (3.08; 2.02-4.70), and decreased as age increased (4055, 0.98, 0.56-1.72; p-value, test for heterogeneity=0.001). Having had a hysterectomy/oophorectomy was associated with higher risk of combined CHD compared to not having had a hysterectomy/oophorectomy (1.51, 1.34-1.71). 42% of the association between endometriosis and CHD could be explained by greater frequency of hysterectomy/oophorectomy and earlier age at surgery following endometriosis diagnosis. Conclusions In this large, prospective cohort, laparoscopically-confirmed endometriosis was associated with increased risk of CHD. The association was strongest among young women. Hysterectomy/oophorectomy was associated with higher risk of CHD and could partially explain the association between endometriosis and CHD. PMID:27025928

  11. Impact of functional focal versus diffuse coronary artery disease on bypass graft patency.

    PubMed

    Shiono, Yasutsugu; Kubo, Takashi; Honda, Kentaro; Katayama, Yosuke; Aoki, Hiroshi; Satogami, Keisuke; Kashiyama, Kuninobu; Taruya, Akira; Nishiguchi, Tsuyoshi; Kuroi, Akio; Orii, Makoto; Kameyama, Takeyoshi; Yamano, Takashi; Yamaguchi, Tomoyuki; Matsuo, Yoshiki; Ino, Yasushi; Tanaka, Atsushi; Hozumi, Takeshi; Nishimura, Yoshiharu; Okamura, Yoshitaka; Akasaka, Takashi

    2016-11-01

    Pressure guidewire pullback recording can differentiate between functional focal and diffuse disease types in coronary artery disease. The aim of this study was to compare the outcome of coronary artery bypass graft (CABG) patency between patients with functional focal versus diffuse disease types in recipient coronary arteries. We investigated 89 patients who underwent pressure guidewire pullback in the left anterior descending (LAD) artery before CABG using internal mammary artery (IMA). Based on the pressure guidewire pullback data, the LAD lesions were classified into functional focal disease (abrupt pressure step-up; n=58) or functional diffuse disease (gradual pressure increase; n=31). Follow-up computed tomography (CT) angiography was conducted within 1year after CABG to assess the bypass graft patency. Pre CABG, LAD angiographic percent diameter stenosis (57±10% vs. 54±12%, p=0.228) and fractional flow reserve (FFR) (0.68±0.07 vs. 0.69±0.07, p=0.244) were not different between the functional focal and diffuse disease groups. The CABG procedure characteristics were similarly comparable between the two groups. In the follow-up CT angiography after CABG, occlusion or string sign of the IMA graft to LAD was more frequently observed in the functional diffuse disease group than in the functional focal disease group (26% vs. 7%, p=0.021). In CABG, functional diffuse disease in the recipient coronary artery was associated with an increased risk of the graft failure in comparison with functional focal disease. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. CFD-based Thrombotic Risk Assessment in Kawasaki Disease Patients with Coronary Artery Aneurysms

    NASA Astrophysics Data System (ADS)

    Sengupta, Dibyendu; Kung, Ethan; Kahn, Andrew; Burns, Jane; Marsden, Alison

    2012-11-01

    Coronary aneurysms occur in 25% of untreated Kawasaki Disease (KD) patients and put patients at increased risk for myocardial infarction and sudden death. Clinical guidelines recommend using aneurysm diameter >8 mm as the arbitrary criterion for treating with anti-coagulation therapy. This study uses patient-specific modeling to non-invasively determine hemodynamic parameters and quantify thrombotic risk. Anatomic models were constructed from CT angiographic image data from 5 KD aneurysm patients and one normal control. CFD simulations were performed to obtain hemodynamic data including WSS and particle residence times (PRT). Thrombosis was clinically observed in 4/9 aneurysmal coronaries. Thrombosed vessels required twice as many cardiac cycles (mean 8.2 vs. 4.2) for particles to exit, and had lower mean WSS (1.3 compared to 2.8 dynes/cm2) compared to vessels with non-thrombosed aneurysms of similar max diameter. 1 KD patient in the cohort with acute thrombosis had diameter < 8 mm. Regions of low WSS and high PRT predicted by simulations correlated with regions of subsequent thrombus formation. Thrombotic risk stratification for KD aneurysms may be improved by incorporating both hemodynamic and geometric quantities. Current clinical guidelines to assess patient risk based only on aneurysm diameter may be misleading. Further prospective study is warranted to evaluate the utility of patient-specific modeling in risk stratifying KD patients with coronary aneurysms. NIH R21.

  13. Multislice spiral computed tomography for the evaluation of stent patency after left main coronary artery stenting: a comparison with conventional coronary angiography and intravascular ultrasound.

    PubMed

    Van Mieghem, Carlos A G; Cademartiri, Filippo; Mollet, Nico R; Malagutti, Patrizia; Valgimigli, Marco; Meijboom, Willem B; Pugliese, Francesca; McFadden, Eugene P; Ligthart, Jurgen; Runza, Giuseppe; Bruining, Nico; Smits, Pieter C; Regar, Evelyn; van der Giessen, Willem J; Sianos, Georgios; van Domburg, Ron; de Jaegere, Peter; Krestin, Gabriel P; Serruys, Patrick W; de Feyter, Pim J

    2006-08-15

    Surveillance conventional coronary angiography (CCA) is recommended 2 to 6 months after stent-supported left main coronary artery (LMCA) percutaneous coronary intervention due to the unpredictable occurrence of in-stent restenosis (ISR), with its attendant risks. Multislice computed tomography (MSCT) is a promising technique for noninvasive coronary evaluation. We evaluated the diagnostic performance of high-resolution MSCT to detect ISR after stenting of the LMCA. Seventy-four patients were prospectively identified from a consecutive patient population scheduled for follow-up CCA after LMCA stenting and underwent MSCT before CCA. Until August 2004, a 16-slice scanner was used (n = 27), but we switched to the 64-slice scanner after that period (n = 43). Patients with initial heart rates > 65 bpm received beta-blockers, which resulted in a mean periscan heart rate of 57 +/- 7 bpm. Among patients with technically adequate scans (n = 70), MSCT correctly identified all patients with ISR (10 of 70) but misclassified 5 patients without ISR (false-positives). Overall, the accuracy of MSCT for detection of angiographic ISR was 93%. The sensitivity, specificity, and positive and negative predictive values were 100%, 91%, 67%, and 100%, respectively. When analysis was restricted to patients with stenting of the LMCA with or without extension into a single major side branch, accuracy was 98%. When both branches of the LMCA bifurcation were stented, accuracy was 83%. For the assessment of stent diameter and area, MSCT showed good correlation with intravascular ultrasound (r = 0.78 and 0.73, respectively). An intravascular ultrasound threshold value > or = 1 mm was identified to reliably detect in-stent neointima hyperplasia with MSCT. Current MSCT technology, in combination with optimal heart rate control, allows reliable noninvasive evaluation of selected patients after LMCA stenting. MSCT is safe to exclude left main ISR and may therefore be an acceptable first

  14. Quantitative angiographic anatomy of the renal arteries and adjacent aorta in the swine for preclinical studies of intravascular catheterization devices.

    PubMed

    Sakaoka, Atsushi; Koshimizu, Masafumi; Nakamura, Shintaro; Matsumura, Kiyoshi

    2018-05-10

    Swine are the most common animal model in preclinical studies of cardiovascular devices. Because of the recent trend for development of new devices for percutaneous catheterization, especially for the renal arteries (RAs), we examined the quantitative anatomical dimensions of the RAs and adjacent aorta in swine. Angiographic images were analyzed in 66 female Yorkshire/Landrace crossbred swine. The diameter of both the right and left main RA was 5.4 ± 0.6 mm. The length of the right main RA was significantly longer than that of the left (29.8 ± 7.5 mm vs. 20.6 ± 5.4 mm, respectively; P<0.001). The diameter of both the right and left branch RA with diameters ≥3 mm (the target vessel diameter of recently developed devices) was 3.8 ± 0.5 mm. The right branch RA was significantly longer than that of the left (18.9 ± 7.8 mm vs. 16.4 ± 7.4 mm, respectively; P<0.05). The branching angle of the right RA from the aorta was significantly smaller than that of the left (91 ± 12° vs. 103 ± 15°, respectively; P<0.001). The diameters of the suprarenal and infrarenal aorta were 10.6 ± 1.1 mm and 9.7 ± 0.9 mm, respectively. In conclusion, because of their similar dimensions to human, swine are an appropriate animal model for assessing the safety of, and determining optimal design of, catheter devices for RAs in simulated clinical use. However, there were species differences in the branching angle and adjacent aorta diameter, suggesting that swine models alone are inadequate to assess the delivery performance of catheter devices for RAs.

  15. Quantitative angiographic anatomy of the renal arteries and adjacent aorta in the swine for preclinical studies of intravascular catheterization devices

    PubMed Central

    Sakaoka, Atsushi; Koshimizu, Masafumi; Nakamura, Shintaro; Matsumura, Kiyoshi

    2018-01-01

    Swine are the most common animal model in preclinical studies of cardiovascular devices. Because of the recent trend for development of new devices for percutaneous catheterization, especially for the renal arteries (RAs), we examined the quantitative anatomical dimensions of the RAs and adjacent aorta in swine. Angiographic images were analyzed in 66 female Yorkshire/Landrace crossbred swine. The diameter of both the right and left main RA was 5.4 ± 0.6 mm. The length of the right main RA was significantly longer than that of the left (29.8 ± 7.5 mm vs. 20.6 ± 5.4 mm, respectively; P<0.001). The diameter of both the right and left branch RA with diameters ≥3 mm (the target vessel diameter of recently developed devices) was 3.8 ± 0.5 mm. The right branch RA was significantly longer than that of the left (18.9 ± 7.8 mm vs. 16.4 ± 7.4 mm, respectively; P<0.05). The branching angle of the right RA from the aorta was significantly smaller than that of the left (91 ± 12° vs. 103 ± 15°, respectively; P<0.001). The diameters of the suprarenal and infrarenal aorta were 10.6 ± 1.1 mm and 9.7 ± 0.9 mm, respectively. In conclusion, because of their similar dimensions to human, swine are an appropriate animal model for assessing the safety of, and determining optimal design of, catheter devices for RAs in simulated clinical use. However, there were species differences in the branching angle and adjacent aorta diameter, suggesting that swine models alone are inadequate to assess the delivery performance of catheter devices for RAs. PMID:29353822

  16. A clinical evaluation of the ProNOVA XR polymer-free sirolimus eluting coronary stent system in the treatment of patients with de novo coronary artery lesions (EURONOVA XR I study)☆

    PubMed Central

    Legutko, Jacek; Zasada, Wojciech; Kałuża, Grzegorz L.; Heba, Grzegorz; Rzeszutko, Lukasz; Jakala, Jacek; Dragan, Jacek; Klecha, Artur; Giszterowicz, Dawid; Dobrowolski, Wojciech; Partyka, Łukasz; Jayaraman, Swaminathan; Dudek, Dariusz

    2013-01-01

    Aims Evaluation of safety and efficacy of ProNOVA XR, a new generation of polymer-free sirolimus eluting stents (SES), utilizing a pharmaceutical excipient for timed release of sirolimus from the XR platform. Methods and results Safety and efficacy of ProNOVA XR coronary stent system was examined in EURONOVA prospective, single arm, multi-center registry of 50 patients with de novo native coronary lesions up to 28 mm in length in arteries between 2.25 and 4 mm. At 6-month, in-stent late lumen loss by QCA was 0.45 ± 0.41 mm and in-stent neointimal volume obstruction in the IVUS sub-study was 14 ± 11%. One-year clinical follow-up revealed a favorable safety profile, with 2% of in-hospital MACE and 6.4% of MACE from hospital discharge up to 12 months (including 1 cardiac death >30 days after stent implantation and 2 TLRs). According to the ARC definition, there was no definite or probable stent thrombosis and 1 possible stent thrombosis (2%) up to 12 months of clinical follow-up. Conclusions In this preliminary evaluation, ProNOVA XR polymer-free sirolimus eluting stent system appeared safe with an early promise of adequate effectiveness in the treatment of de novo coronary lesions in up to 12 months of clinical, angiographic and IVUS follow-up. PMID:23992999

  17. An everolimus-eluting stent versus a paclitaxel-eluting stent in small vessel coronary artery disease: a pooled analysis from the SPIRIT II and SPIRIT III trials.

    PubMed

    Bartorelli, Antonio L; Serruys, Patrick W; Miquel-Hébert, Karine; Yu, Shui; Pierson, Wes; Stone, Gregg W

    2010-07-01

    To evaluate the safety and efficacy of the XIENCE V everolimus-eluting stent compared to the TAXUS paclitaxel-eluting stent in small vessels. The XIENCE V everolimus-eluting stent (EES) has been shown to improve angiographic and clinical outcomes after percutaneous myocardial revascularization, but its performance in small coronary arteries has not been investigated. In this pooled analysis, we studied a cohort of 541 patients with small coronary vessels (reference diameter <2.765 mm) by using patient and lesion level data from the SPIRIT II and SPIRIT III studies. TAXUS Express (73% of lesions) and TAXUS Liberté (27% of lesions) paclitaxel-eluting stents (PES) were used as controls in SPIRIT II. In SPIRIT III, Taxus Express(2) PES was the control. Mean angiographic in-stent and in-segment late loss was significantly less in the EES group compared with the PES group, (0.15 +/- 0.37 mm vs. 0.30 +/- 0.44 mm; P = 0.011 for in-stent; 0.10 +/- 0.38 mm vs. 0.21 +/- 0.34 mm; P = 0.034 for in-segment). EES also resulted in a significant reduction in composite major adverse cardiac events at 1 year (19/366 [5.2%] vs. 17/159 [10.7%]; P = 0.037), due to fewer non-Q-wave myocardial infarctions and target lesion revascularizations. At 1 year, the rate of non-Q-wave myocardial infarction was significantly lower in the EES group compared with that of the PES group (6/366 [1.6%] vs. 8/159 [5.0%]; P = 0.037). In patients with small vessel coronary arteries, the XIENCE V EES was superior to the TAXUS PES. (c) 2010 Wiley-Liss, Inc.

  18. Revascularization with percutaneous coronary intervention does not affect androgen status in males with chronic stable angina pectoris.

    PubMed

    Gosai, J N; Charalampidis, P; Nikolaidou, T; Parviz, Y; Morris, P D; Channer, K S; Jones, T H; Grech, E D

    2016-05-01

    There is a clear association between low serum testosterone and coronary artery disease (CAD) in men. Hypotestosteronaemia is associated with accelerated atherosclerosis and a quarter of men with CAD are biochemically hypogonadal. Amongst those with CAD, hypotestosteronaemia is associated with increased mortality. Testosterone vasodilates coronary arteries, and exogenous testosterone reduces ischaemia. Whether hypotestosteronaemia is a cause or a consequence of CAD remains unanswered. The aim of this prospective observational study was to investigate whether coronary revascularization affected androgen status in men with stable angina pectoris. Twenty five men (mean age 62.7, SD 9.18) with angiographically significant CAD and symptomatic angina underwent full coronary revascularization by percutaneous coronary intervention. Androgen status and symptoms of angina, stress, depression and sexual function were assessed before, and at one and 6 months after the coronary revascularization. All patients underwent complete revascularization which was associated with a significant reduction in angina symptoms and ischaemia. No significant difference was seen in total testosterone (11.33 nmol/L baseline; 12.56, 1 month post; 13.04 at 6 months; p = 0.08). A significant and sustained rise in sex hormone-binding globulin was seen (33.99 nm/L baseline; 36.11 nm/L 1 month post PCI; 37.94 nm/L at 6 months; p = 0.03) Overall, there was no significant alteration in any other marker of androgen status including free testosterone or bioavailable testosterone. There was no change in symptoms of anxiety, depression or sexual function. Coronary revascularization has no sustained effect on androgen status. This supports the hypothesis that hypotestosteronaemia is not a consequence of angina pectoris or myocardial ischaemia. © 2016 American Society of Andrology and European Academy of Andrology.

  19. PLA2G7 genotype, Lp-PLA2 activity and coronary heart disease risk in 10,494 cases and 15,624 controls of European ancestry

    PubMed Central

    Casas, Juan P.; Ninio, Ewa; Panayiotou, Andrie; Palmen, Jutta; Cooper, Jackie A; Ricketts, Sally L; Sofat, Reecha; Nicolaides, Andrew N; Corsetti, James P; Fowkes, F Gerry R; Tzoulaki, Ioanna; Kumari, Meena; Brunner, Eric J; Kivimaki, Mika; Marmot, Michael G; Hoffmann, Michael M; Winkler, Karl; März, Winfred; Ye, Shu; Stirnadel, Heide A; MBBChir, Kay-Tee Khaw; Humphries, Steve E; Sandhu, Manjinder S; Hingorani, Aroon D; Talmud, Philippa J

    2012-01-01

    Background Higher Lp-PLA2 activity is associated with increased risk of coronary heart disease (CHD), making Lp-PLA2 a potential therapeutic target. PLA2G7 variants associated with Lp-PLA2 activity could evaluate whether this relationship is causal. Methods and Results A meta-analysis including a total of 12 studies (5 prospective, 4 case-control, 1 case-only and 2 cross-sectional, n=26,118) was undertaken to examine the association of: (i) LpPLA2 activity vs. cardiovascular biomarkers and risk factors and CHD events (two prospective studies; n=4884); ii) PLA2G7 SNPs and Lp-PLA2 activity (3 prospective, 2 case-control, 2 cross-sectional studies; up to n=6094); and iii) PLA2G7 SNPs and angiographic coronary artery disease (2 case-control, 1 case-only study; n=4971 cases) and CHD events (5 prospective, 2 case-control studies; n=5523). Lp-PLA2 activity correlated with several CHD risk markers. Hazard ratio for CHD events top vs. bottom quartile of Lp-PLA2 activity was 1.61 (95%CI: 1.31, 1.99) and 1.17 (95%CI: 0.91, 1.51) after adjustment for baseline traits. Of seven SNPs, rs1051931 (A379V) showed the strongest association with Lp-PLA2 activity, VV subjects having 7.2% higher activity than AAs. Genotype was not associated with risk markers, angiographic coronary disease (OR 1.03 (95%CI 0.80, 1.32), or CHD events (OR 0.98 (95%CI 0.82, 1.17). Conclusions Unlike Lp-PLA2 activity, PLA2G7 variants associated with modest effects on Lp-PLA2 activity were not associated with cardiovascular risk markers, coronary atheroma or CHD. Larger association studies, identification of SNPs with larger effects, or randomised trials of specific Lp-PLA2 inhibitors are needed to confirm/refute a contributory role for Lp-PLA2 in CHD. PMID:20479152

  20. Absence of gender disparity in short-term clinical outcomes in patients with acute ST-segment elevation myocardial infarction undergoing sirolimus-eluting stent based primary coronary intervention: a report from Shanghai Acute Coronary Event (SACE) Registry.

    PubMed

    Zhang, Qi; Qiu, Jian-Ping; Zhang, Rui-Yan; Li, Yi-Gang; He, Ben; Jin, Hui-Gen; Zhang, Jun-Feng; Wang, Xiao-Long; Jiang, Li; Liao, Min-Lei; Hu, Jian; Shen, Wei-Feng

    2010-04-05

    Randomized, controlled trials have demonstrated the superiority of sirolimus-eluting stent (SES) implantation during primary percutaneous coronary intervention (PCI), as opposed to bare-metal stents, in patients with ST-elevation myocardial infarction (STEMI). This study aimed to test the hypothesis that clinical benefits of SES treatment were independent of gender in this setting. A total of 2042 patients with STEMI undergoing SES-based primary PCI were prospectively enrolled into Shanghai Acute Coronary Event (SACE) registry (1574 men and 468 women). Baseline demographics, angiographic and PCI features, and in-hospital and 30-day major adverse cardiac events (MACE) were analyzed as a function of gender. Compared with men, women were older and more frequently had hypertension, diabetes, and hypercholesterolemia. Use of platelet glycoprotein IIb/IIIa receptor inhibitor (GPI, 65.5% vs. 62.2%, P = 0.10) and procedural success rate (95.0% vs. 94.2%, P = 0.52) were similar in both genders. In-hospital death and MACE occurred in 3.8% and 7.6%, and 4.5% and 8.1% in the male and female patients, respectively (all P > 0.05). At 30-day follow-up, survival (94.3% vs. 93.8%, P = 0.66) and MACE-free survival (90.2% vs. 89.3%, P = 0.52) did not significantly differ between men and women. After adjustment for differences in patient demographics, angiographic and procedural features, there were no significant difference in either in-hospital (OR = 0.77, 95%CI of 0.48 to 1.22, P = 0.30) or 30-day mortality (OR = 1.28, 95%CI of 0.73 to 2.23, P = 0.38) between women and men. Despite more advanced age and clustering of risk factors in women, female patients with STEMI treated by SES-based primary PCI had similar in-hospital and short-term clinical outcomes as their male counterparts.

  1. Tyrosine phosphorylation of platelet derived growth factor β receptors in coronary artery lesions: implications for vascular remodelling after directional coronary atherectomy and unstable angina pectoris

    PubMed Central

    Abe, J; Deguchi, J; Takuwa, Y; Hara, K; Ikari, Y; Tamura, T; Ohno, M; Kurokawa, K

    1998-01-01

    Background—Growth factors such as platelet derived growth factor (PDGF) have been postulated to be important mediators of neointimal proliferation observed in atherosclerotic plaques and restenotic lesions following coronary interventions. Binding of PDGF to its receptor results in intrinsic receptor tyrosine kinase activation and subsequent cellular migration, proliferation, and vascular contraction.
Aims—To investigate whether the concentration of PDGF β receptor tyrosine phosphorylation obtained from directional coronary atherectomy (DCA) samples correlate with atherosclerotic plaque burden, the ability of diseased vessels to remodel, coronary risk factors, and clinical events.
Methods—DCA samples from 59 patients and 15 non-atherosclerotic left internal thoracic arteries (LITA) were analysed for PDGF β receptor tyrosine phosphorylation content by receptor immunoprecipitation and antiphosphotyrosine western blot. The amount of PDGF β receptor phosphorylation was analysed in relation to angiographic follow up data and clinical variables.
Results—PDGF β receptor tyrosine phosphorylation in the 59 DCA samples was greater than in the 15 non-atherosclerotic LITA (mean (SD) 0.84 (0.67) v 0.17 (0.08) over a control standard, p < 0.0001). As evaluated by stepwise regression analysis, incorporation of both PDGF β receptor tyrosine phosphorylation and immediate gain correlated strongly (adjusted r2 = 0.579) with late loss, although PDGF β receptor tyramine phosphorylation alone correlated poorly with late loss. Multivariate regression analysis of coronary risk factors and clinical events revealed unstable angina as the most significant correlate of PDGF β receptor tyrosine phosphorylation (F value 20.009, p < 0.0001).
Conclusions—PDGF β receptor tyrosine phosphorylation in atherosclerotic lesions is increased compared with non-atherosclerotic arterial tissues. The association of PDGF β receptor tyrosine phosphorylation with

  2. Impairment of left ventricular function during coronary angioplastic occlusion evaluated with a nonimaging scintillation probe.

    PubMed

    Hartmann, A; Maul, F D; Zimny, M; Klepzig, H; Vallbracht, C; Kneissl, H G; Schräder, R; Hör, G; Kaltenbach, M

    1991-09-01

    Impairment of left ventricular function during controlled myocardial ischemia induced by coronary angioplasty has been reported from angiographic and echocardiographic studies. Ejection fraction, peak ejection, peak filling rates, and end-systolic and end-diastolic volumes were investigated before, during and after coronary occlusion on-line with a nonimaging scintillation probe. The study consisted of 18 patients (mean age 59 +/- 10 years) with coronary artery stenosis of greater than 70%. During balloon inflation of 60 seconds' duration, coronary occlusion pressure was 31.6 +/- 12 mm Hg. There was no significant change in heart rate. Delay between first and second dilatation was 109 +/- 63 seconds. Ejection fraction decreased from 53 +/- 16 to 40 +/- 12% (first dilatation, p less than 0.01) and to 39 +/- 14% (second dilatation, p less than 0.01) and recovered to 51 +/- 16% 5 minutes after the second dilatation. Peak ejection rate was significantly reduced during the first and second balloon inflations. Peak filling rate decreased from 2.5 +/- 0.8 to 2.0 +/- 0.7 end-diastolic volume.s-1 (first dilatation, p less than 0.01) and to 1.8 +/- 0.7 end-diastolic volume.s-1 (second dilatation, p less than 0.01) and remained reduced at 2.2 +/- 0.7 end-diastolic volume.s-1 (p = not significant) at 5 minutes after the second dilatation. End-systolic and end-diastolic volumes increased significantly during the first and second dilatations and returned to normal after dilatation. It is concluded that short, controlled myocardial ischemia during coronary angioplasty leads to a decrease in systolic and diastolic left ventricular function. Sequential dilatations do not further decrease function if a sufficient interval is kept.

  3. A comparison of the clinical, haemodynamic and angiographic features in right ventricular endomyocardial fibrosis and Ebstein's anomaly of the tricuspid valve.

    PubMed

    Balakrishnan, K G; Sapru, R P; Sasidharan, K; Venkitachalam, C G

    1982-01-01

    The clinical, haemodynamic and angiographic features of 18 patients with right ventricular endomyocardial fibrosis (RVEMF) and 8 patients with Ebstein's anomaly of the tricuspid valve (EATV) have been compared. Diagnosis was confirmed by selective angiography. The position of the tricuspid annulus was identified from selective right ventricular angiograms and confirmed by selective right coronary angiography. In 83% of RVEMF patients the tricuspid annulus was displaced to the left of the spine. A false impression of displacement of the tricuspid leaflet can thus be created. However, a tricuspid leaflet displaced away from the tricuspid annulus was found only in patients with EATV. A considerable overlap exists between the wide spectrum of clinical presentations of the two conditions. Helpful distinguishing features that favour EATV were, the presence of a scratchy diastolic murmur and polyphasic QRS complexes in the ECG. Atrial fibrillation in the ECG, and myocardial calcification or pericardial effusion, whenever present, favour RVEMF.

  4. Prevalence and pattern of abnormal myocardial perfusion in patients with isolated coronary artery ectasia: study by 99mTc-sestamibi radionuclide scintigraphy.

    PubMed

    Ismail, Ahmed M; Rayan, Mona; Adel, Amr; Demerdash, Salah; Atef, Mohamed; Abdallah, Mohamed; Nammas, Wail

    2014-02-01

    We explored the prevalence and pattern of abnormal myocardial perfusion in patients with isolated coronary artery ectasia (CAE), as demonstrated by (99m)Tc-sestamibi scintigraphy. Prospectively, we enrolled 35 patients with angiographically documented CAE and no significant coronary obstruction, who underwent elective coronary angiography. Patients underwent Stress-rest (99m)Tc-sestamibi scintigraphy within 4 days of coronary angiography. They were divided into 2 groups: group I: with normal perfusion scan; and group II: with reversible perfusion defects. The mean age was 49.6 ± 6.9 years; 34 (97.1 %) were males. Seventy-nine (75.2 %) arteries were affected by CAE. Among 79 arteries affected by CAE, affection was diffuse in 37 (46.8 %). Thirteen (37.1 %) patients had normal perfusion scan (group I), whereas 22 (62.9 %) had reversible perfusion defects (group II). Among 22 patients with reversible perfusion defects, 20 (90.9 %) had mild and 2 (9.1 %) had moderate ischemia. Among 49 myocardial segments with reversible perfusion defects, 22 (44.9 %) were basal, 18 (36.7 %) mid-, and 9 (18.4 %) apical segments. Diffuse CAE was significantly more prevalent in group II versus group I, in all 3 major coronary arteries (p < 0.05 for all). In patients with isolated CAE who underwent elective coronary angiography, reversible perfusion defects demonstrated by (99m)Tc-sestamibi scintigraphy were rather prevalent, mostly mild, more likely to affect the basal and mid-segments of the myocardium, and more frequently associated with diffuse ectasia.

  5. Fully quantitative pixel-wise analysis of cardiovascular magnetic resonance perfusion improves discrimination of dark rim artifact from perfusion defects associated with epicardial coronary stenosis.

    PubMed

    Ta, Allison D; Hsu, Li-Yueh; Conn, Hannah M; Winkler, Susanne; Greve, Anders M; Shanbhag, Sujata M; Chen, Marcus Y; Patricia Bandettini, W; Arai, Andrew E

    2018-03-08

    Dark rim artifacts in first-pass cardiovascular magnetic resonance (CMR) perfusion images can mimic perfusion defects and affect diagnostic accuracy for coronary artery disease (CAD). We evaluated whether quantitative myocardial blood flow (MBF) can differentiate dark rim artifacts from true perfusion defects in CMR perfusion. Regadenoson perfusion CMR was performed at 1.5 T in 76 patients. Significant CAD was defined by quantitative invasive coronary angiography (QCA) ≥ 50% diameter stenosis. Non-significant CAD (NonCAD) was defined as stenosis by QCA < 50% diameter stenosis or computed tomographic coronary angiography (CTA) < 30% in all major epicardial arteries. Dark rim artifacts had study specific and guideline-based definitions for comparison purposes. MBF was quantified at the pixel-level and sector-level. In a NonCAD subgroup with dark rim artifacts, stress MBF was lower in the subendocardial than midmyocardial and epicardial layers (2.17 ± 0.61 vs. 3.06 ± 0.75 vs. 3.24 ± 0.80 mL/min/g, both p < 0.001) and was also 30% lower than in remote regions (2.17 ± 0.61 vs. 2.83 ± 0.67 mL/min/g, p < 0.001). However, subendocardial stress MBF in dark rim artifacts was 37-56% higher than in true perfusion defects (2.17 ± 0.61 vs. 0.95 ± 0.43 mL/min/g, p < 0.001). Absolute stress MBF differentiated CAD from NonCAD with an accuracy ranging from 86 to 89% (all p < 0.001) using pixel-level analyses. Similar results were seen at a sector level. Quantitative stress MBF is lower in dark rim artifacts than remote myocardium but significantly higher than in true perfusion defects. If confirmed in larger series, this approach may aid the interpretation of clinical stress perfusion exams. ClinicalTrials.gov Identifier: NCT00027170 ; first posted 11/28/2001; updated 11/27/2017.

  6. New stent design for use in small coronary arteries during percutaneous coronary intervention

    PubMed Central

    Granada, Juan F; Huibregtse, Barbara A; Dawkins, Keith D

    2010-01-01

    Patients with diabetes mellitus, of female gender, increased age, and/or with peripheral vascular disease often develop coronary stenoses in small caliber vessels. This review describes treatment of these lesions with the paclitaxel-eluting 2.25 mm TAXUS® Liberté® Atom™ stent. Given the same stent composition, polymer, antirestenotic drug (paclitaxel), and release kinetics as the first-generation 2.25 mm TAXUS® Express® Atom™ stent, the second-generation TAXUS Liberté Atom stent incorporates improved stent design characteristics, including thinner struts (0.0038 versus 0.0052 inches), intended to increase conformability and deliverability. In a porcine noninjured coronary artery model, TAXUS Liberté Atom stent implantation in small vessels demonstrated complete strut tissue coverage compared with the bare metal stent control, suggesting a similar degree of tissue healing between the groups at 30, 90, and 180 days. The prospective, single-armed TAXUS ATLAS Small Vessel trial demonstrated improved instent late loss (0.28 ± 0.45 versus 0.84 ± 0.57 mm, P < 0.001), instent binary restenosis (13.0% versus 38.1%, P < 0.001), and target lesion revascularization (5.8% versus 17.6%, P < 0.001) at nine months with the TAXUS Liberté Atom stent as compared with the bare metal Express stent control, with similar safety measures between the two groups. The TAXUS Liberté Atom also significantly reduced nine-month angiographic rates of both instent late loss (0.28 ± 0.45 versus 0.44 ± 0.61 mm, P = 0.03) and instent binary restenosis (13.0% versus 25.9%, P = 0.02) when compared with the 2.25 mm TAXUS Express Atom control. The observed reduction in target lesion revascularization with the TAXUS Liberté Atom compared with the TAXUS Express Atom at nine months (5.8% versus 13.7%, P = 0.02) was sustained through three years (10.0% versus 22.1%, P = 0.008) with similar, stable safety outcomes between the groups. In conclusion, these data confirm the safety and favorable

  7. Real‐World Multicenter Registry of Patients with Severe Coronary Artery Calcification Undergoing Orbital Atherectomy

    PubMed Central

    Shlofmitz, Evan; Kaplan, Barry; Alexandru, Dragos; Meraj, Perwaiz; Shlofmitz, Richard

    2016-01-01

    Objectives We evaluated the safety and efficacy of orbital atherectomy in real‐world patients with severe coronary artery calcification (CAC). Background The presence of severe CAC increases the complexity of percutaneous coronary intervention as it may impede stent delivery and optimal stent expansion. Atherectomy may be an indispensable tool for uncrossable or undilatable lesions by modifying severe CAC. Although the ORBIT I and II trials report that orbital atherectomy was safe and effective for the treatment of severe CAC, patients with kidney disease, recent myocardial infarction, long diffuse disease, severe left ventricular dysfunction, and unprotected left main disease were excluded. Methods This retrospective study included 458 consecutive patients with severe CAC who underwent orbital atherectomy followed by stenting from October 2013 to December 2015 at 3 centers. Results The primary endpoint of major adverse cardiac and cerebrovascular events at 30 days was 1.7%. Low rates of 30‐day all‐cause mortality (1.3%), myocardial infarction (1.1%), target vessel revascularization (0%), stroke (0.2%), and stent thrombosis (0.9%) were observed. Angiographic complications were low: perforation was 0.7%, dissection 0.9%, and no‐reflow 0.7%. Emergency coronary artery bypass graft surgery was performed in 0.2% of patients. Conclusion In the largest real‐world study of patients who underwent orbital atherectomy, including high‐risk patients who were not surgical candidates as well as those with very complex coronary anatomy, acute and short‐term adverse clinical event rates were low. A randomized clinical trial is needed to identify the ideal treatment strategy for patients with severe CAC. PMID:27358246

  8. Invasive cardiac procedure use and mortality among South Asian and Chinese Canadians with coronary artery disease.

    PubMed

    Quan, Hude; Khan, Nadia; Li, Bing; Humphries, Karin H; Faris, Peter; Galbraith, P Diane; Graham, Michelle; Knudtson, Merril L; Ghali, William A

    2010-01-01

    Previous studies evaluated cardiac procedure use and outcome over the short term, with relatively few Asian patients included. To determine the likelihood of undergoing percutaneous coronary intervention and coronary artery bypass grafting, and survival during 10.5 years of follow-up after coronary angiography among South Asian, Chinese and other Canadian patients. Using prospective cohort study data from two large Canadian provinces, 3061 South Asian, 1473 Chinese and 77,314 other Canadian patients with angiographically proven coronary artery disease from 1995 to 2004 were assessed, and their revascularization and mortality rates during 10.5 years of follow-up were determined. Compared with other Canadian patients, South Asian and Chinese patients were slightly less likely to undergo revascularization (riskadjusted HR 0.94, 95% CI 0.90 to 0.98 for South Asian patients; and HR 0.94, 95% CI 0.88 to 1.00 for Chinese patients). However, South Asian patients underwent coronary artery bypass grafting (HR 1.00, 95% CI 0.94 to 1.07) and Chinese patients underwent percutaneous coronary intervention (HR 0.96, 95% CI 0.89 to 1.04) as frequently as other Canadian patients. Although the 30-day mortality rate was similar across the three ethnic groups, the mortality rate in the follow-up period was significantly lower for South Asian patients (HR 0.76, 95% CI 0.61 to 0.95) and marginally lower for Chinese patients (HR 0.80, 95% CI 0.60 to 1.07) compared with other Canadian patients. South Asian and Chinese patients used revascularization slightly less but had better survival outcomes than other Canadian patients. The factors underlying the better outcomes for South Asian and Chinese patients warrant further study.

  9. Comparing Angiographic Devascularization with Histologic Penetration after Preoperative Tumor Embolization with Onyx: What Indicates an Effective Procedure?

    PubMed

    Grandhi, Ramesh; Hunnicutt, Christopher T; Harrison, Gillian; Zwagerman, Nathan T; Snyderman, Carl H; Gardner, Paul A; Hartman, Douglas J; Horowitz, Michael

    2015-07-01

    To assess Onyx (Covidien, Irvine, California, United States) efficacy as a preoperative embolic agent for neoplasms of the head, neck, and spine, and to compare angiographic and histologic evidence of tumor penetration as predictors of intraoperative blood loss. Retrospective analysis of preoperative Onyx embolization procedures for treatment of head, neck, and spine tumors from 2009 to 2011. Patient demographics and information relating to the embolization procedure and operation were recorded. Measures of Onyx efficacy included intraoperative blood loss and length of surgery. Angiographic and histologic penetration, in addition to percentage of tumor devascularization, were assessed as predictors of efficacy. A total of 22 patients with 17 head or neck and 5 spinal lesions underwent trans-arterial preoperative Onyx embolization. Good angiographic penetration was reported in 41% of tumors and central histologic penetration in 59%, with mean tumor devascularization of 85.3% (standard deviation [SD]: 12.6%). There was no relationship between angiographic and histologic Onyx penetrance. Mean surgical blood loss was 1342 mL (SD: 1327 mL), and length of surgery was 289 minutes (SD: 162 minutes). Neither angiographic, nor histologic Onyx penetration predicted intraoperative blood loss (p = 0.38 and p = 0.32, respectively) or surgical length (p = 0.62 and 0.90, respectively). Devascularization was not associated with blood loss (p = 0.62), but it was a negative predictor of surgical length (p = 0.013). Preoperative Onyx embolization of head, neck, and spine tumors is capable of deep histologic tumor penetration, even when not visualized on angiography. The lack of association between measures of procedural adequacy suggests that using angiographic devascularization as a measure of procedural efficacy may be of limited utility. Georg Thieme Verlag KG Stuttgart · New York.

  10. Effect of PlA1/A2 glycoprotein IIIa gene polymorphism on the long-term outcome after successful coronary stenting

    PubMed Central

    Le Hello, Claire; Morello, Rémy; Lequerrec, Agnès; Duarte, Christine; Riddell, John; Hamon, Martial

    2007-01-01

    Aim To prospectively determine the role of platelet glycoprotein IIIa (GP IIIa) gene PlA1/PlA2 polymorphism on the long-term clinical outcome in patients with coronary artery disease undergoing coronary stenting. Design and setting Prospective observational study in the University Hospital of Caen (France). Patients and methods 1 111 symptomatic consecutive Caucasian patients treated with percutaneous coronary intervention including stent implantation underwent genotyping for GP IIIa PlA1/A2. Main outcome measures Long-term clinical outcome in terms of the rate of major adverse cardiac events (MACE, ie death from any cause, non-fatal Q wave or non Q wave myocardial infarction, and need for coronary revascularisation) was obtained and subsequently stratified according to the GP IIIa PlA1/A2 polymorphism. Results Three groups of patients were determined according to the GP IIIa PlA1/A2 polymorphism (71.6% had the A1/A1, 25.8% had the A1/A2 and 2.6% had the A2/A2 genotype). These three groups were comparable for all clinical characteristics including sex ratio, mean age, vascular risk factors, previous coronary events, baseline angiographic exam, indication for the percutaneous coronary intervention and drug therapy). The incidence of MACE was similar in these 3 groups of patients during a mean follow-up period of 654+/-152 days. Independent risk factors for MACE were a left ventricular ejection fraction < 40%, absence of treatment with a beta-blocker and absence of treatment with an angiotensin converting enzyme inhibitor during follow-up. Conclusion The GP IIIa PlA1/A2 polymorphism does not influence the clinical long-term outcome in patients with symptomatic coronary disease undergoing percutaneous coronary intervention with stent implantation. PMID:18021403

  11. The Impact of Prediabetes on Two-Year Clinical Outcomes in Patients Undergoing Elective Percutaneous Coronary Intervention.

    PubMed

    Choi, Woong Gil; Rha, Seung Woon; Choi, Byoung Geol; Choi, Se Yeon; Byun, Jae Kyeong; Mashaly, Ahmed; Park, Yoonjee; Jang, Won Young; Kim, Woohyeun; Choi, Jah Yeon; Park, Eun Jin; Na, Jin Oh; Choi, Cheol Ung; Kim, Eung Ju; Park, Chang Gyu; Seo, Hong Seog

    2018-06-01

    Prediabetes is an independent risk factor for cardiovascular disease. However, data on the long term adverse clinical outcomes of prediabetic patients undergoing percutaneous coronary intervention (PCI) with drug-eluting stents (DESs) are scarce. The study population comprised 674 consecutive non-diabetic patients who underwent elective PCI between April 2007 and November 2010. Prediabetes was defined as hemoglobin A1c (HbA1c) of 5.7% to 6.4%. Two-year cumulative clinical outcomes of prediabetic patients (HbA1c of 5.7% to 6.4%, n=242) were compared with those of a normoglycemic group (<5.7%, n=432). Baseline clinical and angiographic characteristics were similar between the two groups, except for higher glucose levels (104.8±51.27 mg/dL vs. 131.0±47.22 mg/dL, p<0.001) on admission in the prediabetes group. There was no significant difference between the two groups in coronary angiographic parameters, except for a higher incidence of diffuse long lesion in the prediabetes group. For prediabetic patients, trends toward higher incidences of binary restenosis (15.6% vs. 9.8 %, p=0.066) and late loss (0.71±0.70 mm vs. 0.59±0.62 mm, p=0.076) were noted. During the 24 months of follow up, the incidence of mortality in prediabetic patients was higher than that in normoglycemic patients (5.5% vs. 1.5%, p=0.007). In our study, a higher death rate and a trend toward a higher incidence of restenosis in patients with prediabetes up to 2 years, compared to those in normoglycemic patients, undergoing elective PCI with contemporary DESs. © Copyright: Yonsei University College of Medicine 2018.

  12. Hemoglobin A1c Level Is Not Related to the Severity of Atherosclerosis in Patients with Acute Coronary Syndrome.

    PubMed

    Wang, Xinhong; Han, Zhenhua; Hao, Guanghua; Li, Yongqin; Dong, Xin; Wang, Congxia

    2015-01-01

    The relationship between hemoglobin A1c (HbA1c) levels and the extent of coronary artery stenosis in patients with acute coronary syndrome (ACS) remains uncertain. The present study aimed to assess the correlation of HbA1c level with angiographic coronary atherosclerosis. 292 consecutive ACS patients were enrolled and stratified into three groups according to HbA1c levels (group 1: < 6.0%, n = 137; group 2: 6.0-6.4%, n = 67; group 3: ≥ 6.5%, n = 88). The severity of coronary arteriosclerosis was assessed by Gensini score. The relationship between HbA1c and Gensini score was analyzed by multiple variables analysis. HbA1c level was not associated with the severity of CAD assessed by Gensini score in patients with ACS, even after the adjustment for other risk factors. However, NT-proBNP, ApoA1 and LVEF levels were independent predictors for CAD severity. Moreover, HbA1c level was not associated with the risk of high Gensini score (> 40) by logistic regression analysis. Diabetes mellitus (DM) and LVEF levels were two independent risk factors for high Gensini score. HbA1c level is not a significant and independent marker for the severity of angiography in ACS patients, even in high-risk patients.

  13. Wound Blush Obtainment Is the Most Important Angiographic Endpoint for Wound Healing.

    PubMed

    Utsunomiya, Makoto; Takahara, Mitsuyoshi; Iida, Osamu; Yamauchi, Yasutaka; Kawasaki, Daizo; Yokoi, Yoshiaki; Soga, Yoshimistu; Ohura, Norihiko; Nakamura, Masato

    2017-01-23

    This study aimed to assess the optimal angiographic endpoint of endovascular therapy (EVT) for wound healing. Several reports have demonstrated acceptable patency and limb salvage rates following infrapopliteal interventions for the treatment of critical limb ischemia (CLI). However, the optimal angiographic endpoint of EVT remains unclear. We conducted a subanalysis of the prospective multicenter OLIVE (Endovascular Treatment for Infrainguinal Vessels in Patients with Critical Limb Ischemia) registry investigation assessing patients who received infrainguinal EVT for CLI. We analyzed data from 185 limbs with ischemic ulcerations classified as Rutherford class 5 or 6, managed with EVT alone (i.e., not undergoing bypass surgery). The wound healing rate after EVT was estimated by the Kaplan-Meier method. The association between final angiographic data and wound healing was assessed employing a Cox proportional hazards model. The overall wound healing rate was 73.5%. The probabilities of wound healing in patients with wound blush obtainment was significantly higher than that of those without wound blush (79.6% vs. 46.5%; p = 0.01). In the multivariate analysis, wound blush obtainment was an independent predictor of wound healing. The presence of wound blush after EVT is significantly associated with wound healing. Wound blush as an angiographic endpoint for EVT may serve as a novel predictor of wound healing in patients with CLI. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. Evaluation of Left and Right Atrial Function in Patients with Coronary Slow-Flow Phenomenon Using Two-Dimensional Speckle Tracking Echocardiography.

    PubMed

    Wang, Yonghuai; Zhang, Yan; Ma, Chunyan; Guan, Zhengyu; Liu, Shuang; Zhang, Weixin; Li, Yuling; Yang, Jun

    2016-06-01

    Coronary slow-flow phenomenon (CSFP) is an angiographic diagnosis characterized by delayed coronary opacification in the absence of obstructive coronary artery disease. Currently, several investigators are focusing on ventricular function assessment in patients with CSFP; however, there is a paucity of data on their atrial function. This study was performed to evaluate left atrial (LA) and right atrial (RA) function in patients with CSFP. Eighty-two patients with CSFP and 55 controls without CSFP were enrolled in the study. Diagnosis of CSFP was made by thrombolysis in myocardial infarction frame count (TFC). The LA and RA global longitudinal strain and strain rate during systole (Ss, SRs), during early diastole (Se, SRe), and during late diastole (Sa, SRa) were measured using two-dimensional speckle tracking echocardiography. In the CSFP group, LA Se and SRe decreased, while LA Sa and SRa increased, compared with the control group. RA Se and SRe were lower in patients with CSFP than in the controls. LA conduit function decreased in patients with CSFP, while contractile function increased. RA conduit function also decreased in patients with CSFP. © 2016, Wiley Periodicals, Inc.

  15. Serum cytokine tumor necrosis factor-alpha and interleukin-6 associated with the severity of coronary artery disease: indicators of an active inflammatory burden?

    PubMed

    Gotsman, Israel; Stabholz, Ayala; Planer, David; Pugatsch, Thea; Lapidus, Ludmila; Novikov, Yelena; Masrawa, Siham; Soskolne, Aubrey; Lotan, Chaim

    2008-07-01

    Atherosclerosis is a chronic inflammatory process resulting in coronary artery disease. To determine the relationship between inflammatory markers and the angiographic severity of CAD. We measured inflammatory markers in consecutive patients undergoing coronary angiography. This included C-reactive protein, fibrinogen, serum cytokines (interleukin-1 beta, IL-1 receptor antagonist, IL-6, IL-8, IL-10) and tumor necrosis factor-alpha), all measured by high sensitivity enzyme-linked immunoabsorbent assay. There was a significant correlation between TNFalpha and the severity of CAD as assessed by the number of obstructed coronary vessels and the Gensini severity score, which is based on the proximity and severity of the lesions. Patients had more coronary vessel disease (> 70% stenosis) with increasing tertiles of serum TNFalpha; the mean number of vessels affected was 1.15, 1.33, and 2.00 respectively (P< 0.001). IL-6 correlated with the Gensini severity score and coronary vessel disease (> 70% stenosis). A weaker correlation was present with IL-1 receptor antagonist. A significant correlation was not found with the other inflammatory markers. After adjustment for major risk factors, multivariate analyses showed that significant independent predictors of CAD vessel disease were TNFalpha (P< 0.05) and combined levels of TNFalpha and IL-6 (P< 0.05). IL-6 levels were independently predictive of Gensini coronary score (P< 0.05). TNFalpha and IL-6 are significant predictors of the severity of coronary artery disease. This association is likely an indicator of the chronic inflammatory burden and an important marker of increased atherosclerosis risk.

  16. Coronary artery aneurysm after stent implantation: acute and long-term results after percutaneous treatment with a stent graft.

    PubMed

    Rubartelli, Paolo; Terzi, Giacomo; Borgo, Lorenzo; Giachero, Corinna

    2002-03-01

    A patient with unstable angina was treated with elective Palmaz-Schatz stent implantation on a focal stenosis of the left circumflex artery. One year later, a large (13 mm in diameter) coronary artery aneurysm was diagnosed at angiography in the stented site. Intravascular ultrasound examination confirmed the presence of a true aneurysm located at the proximal end of the stent. The aneurysm was successfully treated with a Jostent Graft (Jomed Implantate) consisting of two slotted tube stainless steel stents supporting a polytetrafluoroethylene tube. The stent graft was implanted under intravascular ultrasound guidance. The 18-month angiographic follow-up showed good patency of the stent graft and complete exclusion of the aneurysm.

  17. Angiographic and Clinical Impact of Successful Manual Thrombus Aspiration in Diabetic Patients Undergoing Primary PCI

    PubMed Central

    2014-01-01

    Background. Diabetes mellitus is associated with worse angiographic and clinical outcomes after percutaneous coronary intervention (PCI). Aim. To investigate the impact of manual thrombus aspiration on in-stent restenosis (ISR) and clinical outcome in patients treated by bare-metal stent (BMS) implantation for ST-segment elevation myocardial infarction (STEMI). Methods. 100 diabetic patients were prospectively enrolled. They were randomly assigned to undergo either standard primary PCI (group A, 50 patients) or PCI with thrombus aspiration using Export catheter (group B, 50 patients). The primary endpoint was the rate of eight-month ISR. The secondary endpoint included follow-up for major adverse cardiac events (MACE). Results. Mean age of the study cohort was 59.86 ± 8.3 years, with 64 (64%) being males. Baseline characteristics did not differ between both groups. Eight-month angiogram showed that group B patients had significantly less late lumen loss (0.17 ± 0.35 versus 0.60 ± 0.42 mm, P < 0.001), with lower incidence of ISR (4% versus 16.6%, P < 0.001). There was a trend towards lower rate of MACE in the same group of patients. Conclusion. In diabetic patients undergoing primary PCI, manual thrombus aspiration (compared with standard PCI) was associated with better ISR rate after BMS implantation. PMID:24804102

  18. Regional myocardial shape and dimensions of the working isolated canine left ventricle

    NASA Technical Reports Server (NTRS)

    Ritman, E.; Tsuiki, K.; Donald, D.; Wood, E. H.

    1975-01-01

    Angiographic experiments were performed on isolated canine left ventricle preparations using donor dog to supply blood to the coronary circulation via a rotary pump to control coronary flow. The angiographic record was transferred from video tape to video disk for detailed uninterrupted sequential analysis at a frequency of 60 fields/sec. It is shown that the use of a biplane X-ray technique and a metabolically supported isolated canine left ventricle preparation provides an angiographically ideal means of measuring the mechanical dynamics of the myocardium while the intact left ventricular myocardial structure and electrical activation pattern retain most of the in situ ventricular characteristics. In particular, biplane X-ray angiography of the left ventricle can provide estimates of total ventricular function such as ejection fraction, stroke volume, and myocardial mass correct to within 15% under the angiographically ideal conditions of the preparation.

  19. Tong-xin-luo capsule for patients with coronary heart disease after percutaneous coronary intervention.

    PubMed

    Mao, Chen; Fu, Xiao-Hong; Yuan, Jin-Qiu; Yang, Zu-Yao; Chung, Vincent C H; Qin, Ying; Huang, Yafang; Tam, Wilson Wai San; Kwong, Joey S W; Xie, Wei; Tang, Jin-Ling

    2015-05-21

    Percutaneous coronary intervention (PCI) is a standard treatment for coronary heart disease (CHD). Restenosis, defined as a 50% reduction in luminal diameter at six months after PCI, indicates a need for revascularisation. Restenosis has proven to be a major drawback to PCI. Tong-xin-luo is one of the prophylactic strategies for cardiovascular events in patients after PCI that is widely used in China, but its efficacy and safety have not been systematically evaluated. To systematically assess the efficacy and safety of Tong-xin-luo capsules in preventing cardiovascular events after PCI in patients with CHD. We searched the Cochrane Central Register of Controlled Trials in The Cochrane Library, MEDLINE (OVID), EMBASE (OVID), WanFang, Chinese Biomedical Database, Chinese Medical Current Contents, and China National Knowledge Infrastructure from their inception to June 2014. We also searched other resources, including ongoing trials and research registries. We applied no language restrictions. Randomised controlled trials of participants with CHD after PCI were included. Participants in the intervention group received Tong-xin-luo capsules for at least three months. Two review authors independently extracted data and assessed the risk of bias. Any disagreements were resolved by discussion with a third review author. The primary outcomes included occurrence of angiographic restenosis and adverse events; the secondary outcomes included myocardial infarction, heart failure, angina, all cause mortality, mortality due to any cardiovascular event, use of revascularisation, patient acceptability, quality of life and cost-effectiveness. Dichotomous data were measured with risk ratios (RRs) with 95% confidence intervals (CIs). Sixteen studies involving 1063 participants were identified. The risk of bias for fifteen studies was high and along with imprecision and possible publication bias, this lowered our confidence in the results. There was low quality evidence that Tong

  20. Usefulness of coronary calcium scoring to myocardial perfusion SPECT in the diagnosis of coronary artery disease in a predominantly high risk population.

    PubMed

    Schaap, Jeroen; Kauling, Robert M; Boekholdt, S Matthijs; Post, Martijn C; Van der Heyden, Jan A; de Kroon, Thom L; van Es, H Wouter; Rensing, Benno J W M; Verzijlbergen, J Fred

    2013-03-01

    Coronary calcium scoring (CCS) adds to the diagnostic performance of myocardial perfusion single-photon emission computed tomography (SPECT) to assess the presence of significant coronary artery disease (CAD). Patients with a high pre-test likelihood are expected to have a high CCS which potentially could enhance the diagnostic performance of myocardial perfusion SPECT in this specific patient group. We evaluated the added value of CCS to SPECT in the diagnosis of significant CAD in patients with an intermediate to high pre-test likelihood. In total, 129 patients (mean age 62.7 ± 9.7 years, 65 % male) with stable anginal complaints and intermediate to high pre-test likelihood of CAD (median 87 %, range 22-95) were prospectively included in this study. All patients received SPECT and CCS imaging preceding invasive coronary angiography (CA). Fractional flow reserve (FFR) measurements were acquired from patients with angiographically estimated 50-95 % obstructive CAD. For SPECT a SSS > 3 was defined significant CAD. For CCS the optimal cut-off value for significant CAD was determined by ROC curve analysis. The reference standard for significant CAD was a FFR of <0.80 acquired by CA. Significant CAD was demonstrated in 64 patients (49.6 %). Optimal CCS cut-off value for significant CAD was >182.5. ROC curve analysis for prediction of the presence of significant CAD for SPECT, CCS and the combination of CCS and SPECT resulted in an area under the curve (AUC) of 0.88 (95 % CI 81-94), 0.75 (95 % CI 66-83 %) and 0.92 (95 % CI 87-97 %) respectively. The difference of the AUC between SPECT and the combination of CCS and SPECT was 0.05 (P = 0.12). The addition of CCS did not significantly improve the diagnostic performance of SPECT in the evaluation of patients with a predominantly high pre-test likelihood of CAD.

  1. Association of Interleukin-1 Gene cluster polymorphisms with coronary slow flow phenomenon

    PubMed Central

    Mutluer, Ferit Onur; Ural, Dilek; Güngör, Barış; Bolca, Osman; Aksu, Tolga

    2018-01-01

    Objective: Coronary slow flow phenomenon (CSFP) is characterized by the decreased rate of contrast progression in epicardial coronary arte-ries in the absence of significant coronary stenosis. Mounting evidence has showed a significant association between inflammation and CSFP severity. This study aimed to evaluate possible associations between interleukin-1 receptor antagonist (IL-1ra) gene variable number tandem repeat (VNTR), IL-1β -511 single nucleotide (SNP), and IL-1β+3954 SNP mutations with CSFP. Methods: Forty-eight patients with CSFP and 62 controls with angiographically normal coronary arteries were prospectively enrolled in the study. Genotypes were assessed using the polymerase chain reaction (PCR)-based restriction fragment length polymorphism (PCR-RFLP) technique. Results: Homozygote genotype for allele 2 of+3954 C>T 2/2 genotype was significantly more frequent in patients with CSFP than in the control group, whereas 1/2 genotype was more frequent in the control group (35.4% versus 14.5% for 2/2 genotype and 25% versus 35.5% for 1/2 genotype in CSFP and control groups, respectively, X2=6.6; p=0.04). The allelic frequency of allele 2 of this polymorphism was significantly higher in the CSFP group than in the control group (47.9% versus 28.6% in the control group, X2=5.6; p=0.02). However, there was no significant difference with regard to genotype or allelic frequencies of IL-1ra VNTR or IL-1β -511 SNP polymorphisms between patients with CSFP and controls. Conclusion: IL-1β+3954 SNP mutations are significantly more common in patients with CSFP. It may suggest that the tendency for inflammation may contribute to the presence of this phenomenon. PMID:29339698

  2. Usefulness of high-speed rotational coronary venous angiography during cardiac resynchronization therapy.

    PubMed

    Blendea, Dan; Mansour, Moussa; Shah, Ravi V; Chung, Jeffrey; Nandigam, Veena; Heist, E Kevin; Mela, Theofanie; Reddy, Vivek Y; Manzke, Robert; McPherson, Craig A; Ruskin, Jeremy N; Singh, Jagmeet P

    2007-11-15

    Standard coronary venous angiography (SCVA) provides a static, fixed projection of the coronary venous (CV) tree. High-speed rotational coronary venous angiography (RCVA) is a novel method of mapping CV anatomy using dynamic, multiangle visualization. The purpose of this study was to assess the value of RCVA during cardiac resynchronization therapy. Digitally acquired rotational CV angiograms from 49 patients (mean age 69 +/- 11 years) who underwent left ventricular lead implantation were analyzed. RCVA, which uses rapid isocentric rotation over a 110 degrees arc, acquiring 120 frames/angiogram, was compared with SCVA, defined as 2 static orthogonal views: right anterior oblique 45 degrees and left anterior oblique 45 degrees . RCVA demonstrated that the posterior vein-to-coronary sinus (CS) angle and the left marginal vein-to-CS angle were misclassified in 5 and 11 patients, respectively, using SCVA. RCVA identified a greater number of second-order tributaries with diameters >1.5 mm than SCVA. The CV branch selected for lead placement was initially identified in 100% of patients using RCVA but in only 74% of patients using SCVA. RCVA showed that the best angiographic view for visualizing the CS and its tributaries differed significantly among different areas of the CV tree and among patients. The area of the CV tree that showed less variability was the CS ostium, which had a fairly constant relation with the spine in shallow right anterior oblique and left anterior oblique projections. In conclusion, RCVA provided a more precise map of CV anatomy and the spatial relation of venous branches. It allowed the identification of fluoroscopic views that could facilitate cannulation of the CS. The final x-ray view displaying the appropriate CV branch for left ventricular lead implantation was often different from the conventional left anterior oblique and right anterior oblique views. RCVA identified the target branch for lead implantation more often than SCVA.

  3. Natural History of Moderate Coronary Artery Stenosis After Surgical Revascularization.

    PubMed

    Raza, Sajjad; Blackstone, Eugene H; Houghtaling, Penny L; Olivares, Gabriel; Ravichandren, Kirthi; Koprivanac, Marijan; Bakaeen, Faisal G; Sabik, Joseph F

    2018-03-01

    It remains controversial whether grafting moderately stenosed coronary arteries (MSCAs) influences native-vessel disease progression and whether grafting may protect against late myocardial ischemia. From 1972 to 2011, 55,567 patients underwent primary isolated coronary artery bypass grafting (CABG); 1,902 had a single coronary artery with angiographically moderate (50% to 69%) stenosis and ≥1 postoperative angiogram. Disease progression was studied in 489 nongrafted, 371 internal thoracic artery (ITA)-grafted, and 957 saphenous vein (SV)-grafted MSCAs, as well as patency of 376 ITA and 1,016 SV grafts to these MSCAs. At 1, 5, 10, and 15 years, native-vessel disease progressed from moderate to severe stenosis/occlusion in 32%, 52%, 66%, and 72% of nongrafted MSCAs; 55%, 73%, 84%, and 87% of ITA-grafted MSCAs; and 67%, 82%, 90%, and 92% of SV-grafted MSCAs. After adjusting for patient characteristics, MSCA disease progressed 3.6 times faster with ITA and 10 times faster with SV grafting compared with nongrafting. At these same time points, occlusion of ITA grafts to MSCAs was 8%, 9%, 11%, and 15% and for SV grafts, 13%, 32%, 46%, and 56%; protection from myocardial ischemia by ITA-grafted versus nongrafted MSCAs was 29%, 47%, 59%, and 61%. Most MSCAs progress to severe stenosis or occlusion in the long term. Progression is faster in grafted than nongrafted MSCAs, more so with SV than ITA grafts. However, ITA grafts to such arteries have excellent patency, providing long-term protection from myocardial ischemia. Therefore, ITA grafting of MSCAs should be considered. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  4. The Combined Effect of Ear Lobe Crease and Conventional Risk Factor in the Diagnosis of Angiographically Diagnosed Coronary Artery Disease and the Short-Term Prognosis in Patients Who Underwent Coronary Stents

    PubMed Central

    Hou, Xuwei; Jiang, Yu; Wang, Ningfu; Shen, Yun; Wang, Xiaoyan; Zhong, Yigang; Xu, Peng; Zhou, Liang

    2015-01-01

    Abstract The role of diagonal ear lobe crease (DELC) in coronary artery disease (CAD) diagnosis and prognosis remains controversial. In this study, we aimed to assess the combined effect of DELC with other conventional risk factors in the diagnosis and prognosis of CAD in Chinese patients who underwent angiography and coronary stent implantation. The study consisted of 956 consecutive patients who underwent angiography. The DELC was identified as no DELC, unilateral, and bilateral DELC. The conventional risk factors for CAD were recorded. Our dada showed that the overall presence of DELC is associated with CAD risk. Stratification analyses revealed that the diagnostic value of DELC was mostly significant in those with >4 risk factors. Also in patients with >4 risk factors, the presence of bilateral DELC remains to be associated with higher hs-CRP level, higher severity of CAD, and higher possibility of developing major adverse cardiac events after successful percutaneous coronary intervention (PCI). Our study confirmed the relation of DELC with CAD in Chinese patients; more importantly, our data suggest the combination of DELC and CAD risk factors will help to predict the incidence of CAD and may predict the prognosis after successfully PCI. PMID:26131833

  5. A randomized comparison of the Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft (SAVE RITA) trial: One-year angiographic results and mid-term clinical outcomes.

    PubMed

    Kim, Ki-Bong; Hwang, Ho Young; Hahn, Seokyung; Kim, Jun Sung; Oh, Se Jin

    2014-09-01

    The Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft (SAVE RITA) trial was designed to evaluate the noninferiority of the saphenous vein (SV) compared with the right internal thoracic artery ([R]ITA) used as a Y-composite graft. A total of 224 patients who had undergone off-pump revascularization for multivessel coronary artery disease using the SV or RITA as a Y-composite graft based on the in situ left ITA were assigned randomly to the SV Y-composite graft (SV group, n = 112) or free RITA Y-composite graft (RITA group, n = 112). The primary endpoint was the 1-year angiographic patency rate of the second limb conduits (SV or RITA). Postoperative 1-year coronary angiograms were performed in 215 patients (SV group, 108; RITA group, 107). The overall graft patency rate was 97.4% (745 of 765) at 1 year (97.9% in the SV group vs 96.9% in the RITA group, P = .362). The primary endpoint of the study, the 1-year patency rate of the SV composite grafts, was 97.1% (238 of 245) and was noninferior to that of the RITA composite grafts (97.1% [198 of 204]) with a 95% lower confidence limit of -2.6% (P < .001 for noninferiority). The graft qualities, evaluated using the FitzGibbon patency grades, were also similar between the 2 groups (P = .948). No statistically significant differences were found in the overall survival rates between the 2 groups at 1 and 4 years (P = .998). Also, no statistically significant differences were found between the 2 groups in the freedom from major adverse cardiac and cerebrovascular event rates at 1 and 4 years (P = .597). The SV composite grafts were noninferior to the RITA composite grafts in terms of the 1-year angiographic patency rates. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  6. [Expression of PTEN in Myocardial Tissue in Coronary Heart Disease].

    PubMed

    Li, Xue-rong; He, Yong; Lei, Yu-jia; Qin, Xe-he; Wei, Qing-tao; Pan, Xin-min; Li, Li-juan; Zhang, Lin

    2016-04-01

    To observe the expression of phosphatase and tensin homology deleted on chromosome ten (PTEN) in myocardial tissue in patients with coronary heart disease, and explore the relevance between the expression of PTEN and the occurrence and development of coronary heart disease. A total of 16 death cases with pathological diagnosis of coronary heart disease were collected as experimental group, and 19 cases without myocardial lesions were selected as control group. The expression of PTEN protein and its mRNA were detected by immunohistochemistry and real-time fluorescence quantitative PCR respectively. The correlation between the expression of PTEN and the pathogenesis of coronary heart disease was analyzed. The expression of PTEN protein in myocardium in cases with coronary heart disease was significantly lower compared with the control group (P < 0.05). There was no statistical difference of the expression of PTEN mRNA between experimental and control group (P > 0.05). PTEN may be involved in the occurrence and development of coronary heart disease.

  7. Comparative cath-lab assessment of coronary stenosis by radiology technician, junior and senior interventional cardiologist in patients treated with coronary angioplasty

    PubMed Central

    Delli Carri, Felice; Ruggiero, Maria Assunta; Cuculo, Andrea; Ruggiero, Antonio; Ziccardi, Luigi; De Gennaro, Luisa; Di Biase, Matteo

    2014-01-01

    Background Exact quantification of plaque extension during coronary angioplasty (PCI) usually falls on interventional cardiologist (IC). Quantitative coronary stenosis assessment (QCA) may be possibly committed to the radiology technician (RT), who usually supports cath-lab nurse and IC during PCI. We therefore sought to investigate the reliability of QCA performed by RT in comparison with IC. Methods Forty-four consecutive patients with acute coronary syndrome underwent PCI; target coronary vessel size beneath target coronary lesion (S) and target coronary lesion length (L) were assessed by the RT, junior IC (JIC), and senior IC (SIC) and then compared. SIC evaluation, which determined the final stent selection for coronary stenting, was considered as a reference benchmark. Results RT performance with QCA support in assessing target vessel size and target lesion length was not significantly different from SIC (r = 0.46, p < 0.01; r = 0.64, p < 0.001, respectively) as well as JIC (r = 0.79, r = 0.75, p < 0.001, respectively). JIC performance was significantly better than RT in assessing target vessel size (p < 0.05), while not significant when assessing target lesion length. Conclusions RT may reliably assess target lesion by using adequate QCA software in the cath-lab in case of PCI; RT performance does not differ from SIC. PMID:24672672

  8. Comparative cath-lab assessment of coronary stenosis by radiology technician, junior and senior interventional cardiologist in patients treated with coronary angioplasty.

    PubMed

    Brunetti, Natale Daniele; Delli Carri, Felice; Ruggiero, Maria Assunta; Cuculo, Andrea; Ruggiero, Antonio; Ziccardi, Luigi; De Gennaro, Luisa; Di Biase, Matteo

    2014-03-01

    Exact quantification of plaque extension during coronary angioplasty (PCI) usually falls on interventional cardiologist (IC). Quantitative coronary stenosis assessment (QCA) may be possibly committed to the radiology technician (RT), who usually supports cath-lab nurse and IC during PCI. We therefore sought to investigate the reliability of QCA performed by RT in comparison with IC. Forty-four consecutive patients with acute coronary syndrome underwent PCI; target coronary vessel size beneath target coronary lesion (S) and target coronary lesion length (L) were assessed by the RT, junior IC (JIC), and senior IC (SIC) and then compared. SIC evaluation, which determined the final stent selection for coronary stenting, was considered as a reference benchmark. RT performance with QCA support in assessing target vessel size and target lesion length was not significantly different from SIC (r = 0.46, p < 0.01; r = 0.64, p < 0.001, respectively) as well as JIC (r = 0.79, r = 0.75, p < 0.001, respectively). JIC performance was significantly better than RT in assessing target vessel size (p < 0.05), while not significant when assessing target lesion length. RT may reliably assess target lesion by using adequate QCA software in the cath-lab in case of PCI; RT performance does not differ from SIC.

  9. Diagnostic Accuracy of CT Coronary Angiography According to Pretest Probability of Coronary Artery Disease and Severity of Coronary Arterial Calcification: The CorE-64 International, Multicenter Study

    PubMed Central

    Arbab-Zadeh, Armin; Miller, Julie M; Rochitte, Carlos E; Dewey, Marc; Niinuma, Hiroyuki; Gottlieb, Ilan; Paul, Narinder; Clouse, Melvin E.; Shapiro, Edward P.; Hoe, John; Lardo, Albert C.; Bush, David E.; de Roos, Albert; Cox, Christopher; Brinker, Jeffrey; Lima, Joăo A. C.

    2012-01-01

    Objectives Assess the impact of patient population characteristics on accuracy by CT angiography (CTA) to detect obstructive coronary artery disease (CAD). Background The ability of CTA to exclude obstructive CAD in patients of different pretest probabilities and in presence of coronary calcification remains uncertain. Methods For the CorE-64 study 371 patients underwent CTA and cardiac catheterization for the detection of obstructive CAD defined as 50% or greater luminal stenosis by quantitative coronary angiography (QCA). This analysis includes 80 initially excluded patients with a calcium score ≥ 600. Area under the receiver-operating-characteristics curve (AUC) was used to evaluate CTA diagnostic accuracy compared to QCA in patients according to calcium score and pretest probability of CAD. Results Analysis of patient-based quantitative CTA accuracy revealed an AUC of 0.93 (95% confidence interval [CI] 0.90-0.95). AUC remained 0.93 (0.90-0.96) after excluding patients with known CAD but decreased to 0.81 (0.71-0.89) in patients with calcium score ≥ 600 (p=0.077). While AUC were similar (0.93, 0.92, and 0.93, respectively) for patients with intermediate, high pretest probability for CAD, and known CAD, negative predictive values were different: 0.90, 0.83, and 0.50, respectively. Negative predictive values decreased from 0.93 to 0.75 for patients with calcium score < or ≥ 100, respectively (p= 0.053). Conclusions Both pretest probability for CAD and coronary calcium scoring should be considered before using CTA for excluding obstructive CAD. CTA is less effective for this purpose in patients with calcium score ≥ 600 and in patients with a high pretest probability for obstructive CAD. PMID:22261160

  10. First experiences with model based iterative reconstructions influence on quantitative plaque volume and intensity measurements in coronary computed tomography angiography.

    PubMed

    Precht, H; Kitslaar, P H; Broersen, A; Gerke, O; Dijkstra, J; Thygesen, J; Egstrup, K; Lambrechtsen, J

    2017-02-01

    Investigate the influence of adaptive statistical iterative reconstruction (ASIR) and the model-based IR (Veo) reconstruction algorithm in coronary computed tomography angiography (CCTA) images on quantitative measurements in coronary arteries for plaque volumes and intensities. Three patients had three independent dose reduced CCTA performed and reconstructed with 30% ASIR (CTDI vol at 6.7 mGy), 60% ASIR (CTDI vol 4.3 mGy) and Veo (CTDI vol at 1.9 mGy). Coronary plaque analysis was performed for each measured CCTA volumes, plaque burden and intensities. Plaque volume and plaque burden show a decreasing tendency from ASIR to Veo as median volume for ASIR is 314 mm 3 and 337 mm 3 -252 mm 3 for Veo and plaque burden is 42% and 44% for ASIR to 39% for Veo. The lumen and vessel volume decrease slightly from 30% ASIR to 60% ASIR with 498 mm 3 -391 mm 3 for lumen volume and vessel volume from 939 mm 3 to 830 mm 3 . The intensities did not change overall between the different reconstructions for either lumen or plaque. We found a tendency of decreasing plaque volumes and plaque burden but no change in intensities with the use of low dose Veo CCTA (1.9 mGy) compared to dose reduced ASIR CCTA (6.7 mGy & 4.3 mGy), although more studies are warranted. Copyright © 2016 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  11. Safety of low dose heparin in elective coronary angioplasty.

    PubMed Central

    Koch, K. T.; Piek, J. J.; de Winter, R. J.; David, G. K.; Mulder, K.; Tijssen, J. G.; Lie, K. I.

    1997-01-01

    OBJECTIVES: To evaluate the safety of a low dose of heparin in consecutive stable patients undergoing elective percutaneous transluminal coronary angioplasty (PTCA). DESIGN: Open prospective study in a single centre. PATIENTS: 1375 consecutive patients had elective PTCA (1952 lesions: type A 11%, B1 34%, B2 36%, and C 19%). There were no angiographic exclusion criteria. INTERVENTIONS: A bolus of 5000 IU heparin was used as the standard anticoagulation regimen during PTCA. The sheaths were removed immediately after successful completion of the procedure. Prolongation of heparin treatment was left to the operator's discretion. MAIN OUTCOME MEASURES: Procedural success was defined as < 50% residual stenosis without death from any cause, acute myocardial infarction, urgent coronary bypass surgery, or repeat angioplasty within 48 hours for acute recurrent ischaemia; the need for prolonged heparinisation; and the occurrence of puncture site complications. RESULTS: Procedural success without clinical events was achieved in 90% of patients. Mortality was 0.3%; coronary bypass surgery was performed in 1.7% of the procedures. The rate of myocardial infarction was 3.3%; repeat angioplasty within 48 hours was carried out in 0.7% of patients. A total of 89.1% of the patients were treated according to the protocol. Prolonged treatment with heparin was considered necessary in 123 patients (8.9%). Repeat angioplasty for abrupt closure was performed in two patients shortly after sheath removal and in two during prolonged heparinisation. Puncture site complications occurred in 2.1% of patients (low dose heparin 1.9% and prolonged heparinisation 4.9%). CONCLUSION: Elective PTCA can be safely performed using a low dose of heparin, with a negligible risk for subacute closure. Low dose heparin may reduce the incidence of puncture site complications, shorten hospitalisation, and enable out-patient angioplasty. PMID:9227294

  12. Real-World Multicenter Registry of Patients with Severe Coronary Artery Calcification Undergoing Orbital Atherectomy.

    PubMed

    Lee, Michael S; Shlofmitz, Evan; Kaplan, Barry; Alexandru, Dragos; Meraj, Perwaiz; Shlofmitz, Richard

    2016-08-01

    We evaluated the safety and efficacy of orbital atherectomy in real-world patients with severe coronary artery calcification (CAC). The presence of severe CAC increases the complexity of percutaneous coronary intervention as it may impede stent delivery and optimal stent expansion. Atherectomy may be an indispensable tool for uncrossable or undilatable lesions by modifying severe CAC. Although the ORBIT I and II trials report that orbital atherectomy was safe and effective for the treatment of severe CAC, patients with kidney disease, recent myocardial infarction, long diffuse disease, severe left ventricular dysfunction, and unprotected left main disease were excluded. This retrospective study included 458 consecutive patients with severe CAC who underwent orbital atherectomy followed by stenting from October 2013 to December 2015 at 3 centers. The primary endpoint of major adverse cardiac and cerebrovascular events at 30 days was 1.7%. Low rates of 30-day all-cause mortality (1.3%), myocardial infarction (1.1%), target vessel revascularization (0%), stroke (0.2%), and stent thrombosis (0.9%) were observed. Angiographic complications were low: perforation was 0.7%, dissection 0.9%, and no-reflow 0.7%. Emergency coronary artery bypass graft surgery was performed in 0.2% of patients. In the largest real-world study of patients who underwent orbital atherectomy, including high-risk patients who were not surgical candidates as well as those with very complex coronary anatomy, acute and short-term adverse clinical event rates were low. A randomized clinical trial is needed to identify the ideal treatment strategy for patients with severe CAC. © 2016 The Authors. Journal of Interventional Cardiology Published by Wiley Periodicals, Inc.

  13. Absence of accelerated atherosclerotic disease progression after intracoronary infusion of bone marrow derived mononuclear cells in patients with acute myocardial infarction--angiographic and intravascular ultrasound--results from the TErapia Celular Aplicada al Miocardio Pilot study.

    PubMed

    Arnold, Roman; Villa, Adolfo; Gutiérrez, Hipólito; Sánchez, Pedro L; Gimeno, Federico; Fernández, Maria E; Gutiérrez, Oliver; Mota, Pedro; Sánchez, Ana; García-Frade, Javier; Fernández-Avilés, Francisco; San Román, Jose A

    2010-06-01

    We tried to evaluate a putative negative effect on coronary atherosclerosis in patients receiving intracoronary infusion of unfractionated bone marrow mononuclear cells (BMMC) following an acute ST-elevation myocardial infarction. Peripheral blood mononuclear cells or enriched CD133(+) BMMC have been associated with accelerated atherosclerosis of the distal segment of the infarct related artery (IRA). Thirty-seven patients with ST-elevation myocardial infarction from the TECAM pilot study underwent intracoronary infusion of autologous BMMC 9 +/- 3.1 days after onset of symptoms. We compared angiographic changes from baseline to 9 months of follow-up in the distal non-stented segment of the IRA, as well as in the contralateral coronary artery, with a matched control group. A subgroup of 15 treated patients underwent additional IVUS within the distal segment of the IRA. No difference between stem cell and control group were found regarding changes in minimum lumen diameter (0.006 +/- 0.42 vs 0.06 +/- 0.41 mm, P = ns) and the percentage of stenosis (-2.68 +/- 12.33% vs -1.78 +/- 8.75%, P = ns) at follow-up. Likewise, no differences were seen regarding changes in the contralateral artery (minimum lumen diameter -0.004 +/- 0.54 mm vs -0.06 +/- 0.35 mm, P = ns). In the intravascular ultrasound substudy, no changes were demonstrated comparing baseline versus follow-up in maximum area stenosis and plaque volume. In this pilot study, analysis of a subgroup of patients found that intracoronary injection of unfractionated BMMC in patients with acute ST-elevation myocardial infarction was not associated with accelerated atherosclerosis progression at mid term. Prospective, randomised studies in large cohorts with long-term angiographic and intravascular ultrasound follow-up are necessary to determine the safety of this therapy. Copyright 2010 Mosby, Inc. All rights reserved.

  14. Alternative diagnostic strategies for coronary artery disease in women: demonstration of the usefulness and efficiency of probability analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Melin, J.A.; Wijns, W.; Vanbutsele, R.J.

    Alternative strategies using conditional probability analysis for the diagnosis of coronary artery disease (CAD) were examined in 93 infarct-free women presenting with chest pain. Another group of 42 consecutive female patients was prospectively analyzed. For this latter group, the physician had access to the pretest and posttest probability of CAD before coronary angiography. These 135 women all underwent stress electrocardiographic, thallium scintigraphic, and coronary angiographic examination. The pretest and posttest probabilities of coronary disease were derived from a computerized Bayesian algorithm. Probability estimates were calculated by the four following hypothetical strategies: SO, in which history, including risk factors, was considered;more » S1, in which history and stress electrocardiographic results were considered; S2, in which history and stress electrocardiographic and stress thallium scintigraphic results were considered; and S3, in which history and stress electrocardiographic results were used, but in which stress scintigraphic results were considered only if the poststress probability of CAD was between 10% and 90%, i.e., if a sufficient level of diagnostic certainty could not be obtained with the electrocardiographic results alone. The strategies were compared with respect to accuracy with the coronary angiogram as the standard. For both groups of women, S2 and S3 were found to be the most accurate in predicting the presence or absence of coronary disease (p less than .05). However, it was found with use of S3 that more than one-third of the thallium scintigrams could have been avoided without loss of accuracy. It was also found that diagnostic catheterization performed to exclude CAD as a diagnosis could have been avoided in half of the patients without loss of accuracy.(ABSTRACT TRUNCATED AT 250 WORDS)« less

  15. Endovascular Management of the Arteria Profunda Femoralis: Long-Term Angiographic and Clinical Outcomes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karnabatidis, Dimitrios, E-mail: karnaby@med.upatras.gr; Spiliopoulos, Stavros; Pastromas, Georgios

    2012-10-15

    Purpose: This study was designed to investigate the long-term angiographic and clinical outcomes of percutaneous transluminal angioplasty (PTA) of the arteria profunda femoralis (PFA), in a series of patients suffering from critical limb ischemia (CLI) or severe intermittent claudication (IC). Methods: Our department's database was searched to identify patients who underwent PTA or bail-out stenting of the PFA. Among the study's inclusion criteria were Rutherford categories 3-6 and {>=}70% stenosis of the PFA. Only de novo stenotic lesions were assessed. Primary endpoints were technical success, angiographic lesion primary patency, angiographic binary in-lesion restenosis, and target lesion recanalization (TLR) rates. Secondarymore » endpoints included patient survival, limb salvage, and complication rates. Patient's baseline demographics, lesion, and procedural details were analyzed. Results: Between 2001 and 2011, 20 consecutive patients (17 males) with a mean age of 73 {+-} 9 (range 53-87) years underwent PTA or bail-out stenting in 23 PFA lesions. Critical limb ischemia was the indication in eight of 20 patients (40%). The mean lesion length was 31 {+-} 9.5 mm. The procedural technical success was 100% (23/23), whereas mean time angiographic and clinical follow-up was 26.8 {+-} 24.6 months. According to the Kaplan-Meier analysis, primary patency and binary restenosis rate were 95 and 86.1% respectively up to 8 years follow-up. No TLR procedures were performed. The 8-year patient survival and limb salvage rates were 87.5 and 84.7% respectively. Conclusions: PTA or stenting of focal, stenotic, PFA lesions, in patients suffering from CLI or IC, exhibit high long-term primary patency rates, as well as low binary restenosis and TLR rates. Large, multicenter studies are required to validate these results.« less

  16. A vessel segmentation method for multi-modality angiographic images based on multi-scale filtering and statistical models.

    PubMed

    Lu, Pei; Xia, Jun; Li, Zhicheng; Xiong, Jing; Yang, Jian; Zhou, Shoujun; Wang, Lei; Chen, Mingyang; Wang, Cheng

    2016-11-08

    Accurate segmentation of blood vessels plays an important role in the computer-aided diagnosis and interventional treatment of vascular diseases. The statistical method is an important component of effective vessel segmentation; however, several limitations discourage the segmentation effect, i.e., dependence of the image modality, uneven contrast media, bias field, and overlapping intensity distribution of the object and background. In addition, the mixture models of the statistical methods are constructed relaying on the characteristics of the image histograms. Thus, it is a challenging issue for the traditional methods to be available in vessel segmentation from multi-modality angiographic images. To overcome these limitations, a flexible segmentation method with a fixed mixture model has been proposed for various angiography modalities. Our method mainly consists of three parts. Firstly, multi-scale filtering algorithm was used on the original images to enhance vessels and suppress noises. As a result, the filtered data achieved a new statistical characteristic. Secondly, a mixture model formed by three probabilistic distributions (two Exponential distributions and one Gaussian distribution) was built to fit the histogram curve of the filtered data, where the expectation maximization (EM) algorithm was used for parameters estimation. Finally, three-dimensional (3D) Markov random field (MRF) were employed to improve the accuracy of pixel-wise classification and posterior probability estimation. To quantitatively evaluate the performance of the proposed method, two phantoms simulating blood vessels with different tubular structures and noises have been devised. Meanwhile, four clinical angiographic data sets from different human organs have been used to qualitatively validate the method. To further test the performance, comparison tests between the proposed method and the traditional ones have been conducted on two different brain magnetic resonance angiography

  17. Relationship between Angiographic Results and Morphology in Sidewall Intracranial Aneurysms after Stent-Assisted Coil Embolization.

    PubMed

    Nii, Kouhei; Aikawa, Hiroshi; Tsutsumi, Masanori; Eto, Ayumu; Iko, Minoru; Sakamoto, Kimiya; Inoue, Ritsuro; Mitsutake, Takafumi; Hanada, Hayatsura; Kazekawa, Kiyoshi

    2016-03-01

    Stent-assisted coil embolization (SACE) is used to address wide-necked or complex aneurysms. However, as they may recanalize after SACE, predictors of recanalization are needed. We investigated the relationship between follow-up angiographic results and the morphology of sidewall (SW) aneurysms in patients treated by SACE. Between September 2010 and September 2014, we performed 80 SACE procedures for SW intracranial aneurysms. Angiographic findings, obtained immediately after the procedure, 3-6 months thereafter, and when aneurysmal recanalization was suspected on MR angiogram scan, were recorded. Morphologically, the SW aneurysms were classified as "outside" (OS) and "partially inside" (PI) based on the curve of the axes of the proximal or distal parent artery with respect to the aneurysmal neck. Follow-up angiographic studies on OS- and PI SW aneurysms were compared. On the initial angiograms, we classified 42 aneurysms as OS and 38 as PI. Immediately after SACE, there was no significant difference in the angiographic findings on OS and PI aneurysms. However, on follow-up angiograms, there was a significant difference in the rate of spontaneous improvement (4 of 42 [OS] versus 21 of 38 [PI], P = .001). We performed additional coil embolization to treat 3 recanalized OS aneurysms. SW aneurysms classified morphologically as PI tended to occlude progressively even after incomplete occlusion by SACE. In contrast, aneurysms classified as OS must be observed carefully after SACE. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  18. Clinical application of a light-pen computer system for quantitative angiography

    NASA Technical Reports Server (NTRS)

    Alderman, E. L.

    1975-01-01

    The paper describes an angiographic analysis system which uses a video disk for recording and playback, a light-pen for data input, minicomputer processing, and an electrostatic printer/plotter for hardcopy output. The method is applied to quantitative analysis of ventricular volumes, sequential ventriculography for assessment of physiologic and pharmacologic interventions, analysis of instantaneous time sequence of ventricular systolic and diastolic events, and quantitation of segmental abnormalities. The system is shown to provide the capability for computation of ventricular volumes and other measurements from operator-defined margins by greatly reducing the tedium and errors associated with manual planimetry.

  19. Predictors of Excess Patient Radiation Exposure During Chronic Total Occlusion Coronary Intervention: Insights from a Contemporary Multicenter Registry

    PubMed Central

    Christakopoulos, Georgios E.; Christopoulos, Georgios; Karmpaliotis, Dimitri; Alaswad, Khaldoon; Yeh, Robert W.; Jaffer, Farouc A.; Wyman, Michael R.; Lombardi, William L.; Tarar, Muhammad Nauman J.; Grantham, J. Aaron; Kandzari, David; Lembo, Nicholas; Moses, Jeffrey W.; Kirtane, Ajay; Parikh, Manish; Green, Philip; Finn, Matthew; Garcia, Santiago; Doing, Anthony; Hatem, Raja; Thompson, Craig A.; Banerjee, Subhash; Brilakis, Emmanouil S.

    2016-01-01

    Background High patient radiation dose during chronic total occlusion (CTO) percutaneous coronary intervention (PCI) may lead to procedural failure and radiation skin injury. Methods We examined the association between several clinical and angiographic variables on patient air kerma (AK) radiation dose among 748 consecutive CTO PCIs performed at 9 experienced US centers between May 2012 and May 2015. Results Mean age was 65±10 years, 87% of patients were men, and 35% had prior coronary artery bypass graft surgery (CABG). Technical and procedural success was 92% and 90%, respectively. The median patient AK dose was 3.40 (2.00, 5.40) Gray and 34% of the patients received >4.8 Gray (high radiation exposure). On univariable analysis male gender (p=0.016), high body mass index (p<0.001), history of hyperlipidemia (p=0.023), prior CABG (p<0.001), moderate or severe calcification (p<0.001), tortuosity (p<0.001), proximal cap ambiguity (p=0.001), distal cap at a bifurcation (p=0.006), longer CTO occlusion length (p<0.001), blunt/no blunt stump (p<0.001), and center (<0.001) were associated with higher patient AK dose. On multivariable analysis high body mass index (p<0.001), prior CABG (p=0.005), moderate or severe calcification (p=0.005), longer CTO occlusion length (p<0.001), and center (p<0.001) were independently associated with higher patient AK dose. Conclusions Approximately 1 in 3 patients undergoing CTO PCI receives high AK radiation dose (>4.8 Gray). Several baseline clinical and angiographic characteristics can help predict the likelihood of high radiation dose and assist with intensifying efforts to reduce radiation exposure for the patient and the operator. PMID:28169091

  20. Coronary artery dimensions: Iranian population versus Indo-Asians and Caucasians.

    PubMed

    Ghaffari, Samad; Mehdizadeh-Lame, Mohammad-Bagher; Sepehrvand, Nariman; Aslanabadi, Naser; Sohrabi, Bahram; Separham, Ahmad; Jamshidi, Peiman

    2015-10-01

    The dimensions of the coronary arteries have been shown to vary among ethnic groups. There are no data available regarding the normal size of coronary arteries in Iranians. This study aimed to investigate normal coronary artery dimensions in a Northwestern Iranian population and to compare it with pooled data of Indo-Asians and Caucasians in previous studies. The study included 200 adults with suspected coronary disease who were referred for elective coronary angiography between June 2012 and March 2013 and were found to have normal epicardial flow in the coronary arteries. Quantitative coronary angiography was carried out on the longest atheroma-free part of the proximal segment of each coronary artery in all patients. Two Indo-Asian and Caucasian groups were selected and pooled for comparison with the available reports on individuals without coronary artery disease. The mean diameters of the left main coronary artery, proximal left anterior descending artery, proximal left circumflex, and proximal right coronary artery were 4.58 ± 0.80, 3.69 ± 0.64, 3.37 ± 0.73, and 3.47 ± 0.68 mm, respectively. The dimensions of the proximal part of the left main coronary artery and right coronary artery were significantly greater in the Northwestern Iranian population compared to the pooled Caucasian group. This difference was maintained even after correction for body surface area. Our data indicate larger coronary diameters in the Iranian population compared to Caucasians or South-Asians. Hence the high prevalence of coronary artery disease in Iran cannot be explained by coronary dimensions. © The Author(s) 2015.

  1. Stereotactic radiosurgery of angiographically occult vascular malformations: Indications and preliminary experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kondziolka, D.; Lunsford, L.D.; Coffey, R.J.

    1990-12-01

    Stereotactic radiosurgery has been shown to treat successfully angiographically demonstrated arteriovenous malformations of the brain. Angiographic obliteration has represented cure and eliminated the risk of future hemorrhage. The role of radiosurgery in the treatment of angiographically occult vascular malformations (AOVMs) has been less well defined. In the initial 32 months of operation of the 201-source cobalt-60 gamma knife at the University of Pittsburgh, 24 patients meeting strict criteria for high-risk AOVMs were treated. Radiosurgery was used conservatively; each patient had sustained two or more hemorrhages and had a magnetic resonance imaging-defined AOVM located in a region of the brain wheremore » microsurgical removal was judged to pose an excessive risk. Venous angiomas were excluded by performance of high-resolution subtraction angiography in each patient. Fifteen malformations were in the medulla, pons, and/or mesencephalon, and 5 were located in the thalamus or basal ganglia. Follow-up ranged from 4 to 24 months. Nineteen patients either improved or remained clinically stable and did not hemorrhage again during the follow-up interval. One patient suffered another hemorrhage 7 months after radiosurgery. Five patients experienced temporary worsening of pre-existing neurological deficits that suggested delayed radiation injury. Magnetic resonance imaging demonstrated signal changes and edema surrounding the radiosurgical target. Dose-volume guidelines for avoiding complications were constructed. Our initial experience indicates that stereotactic radiosurgery can be performed safely in patients with small, well-circumscribed AOVMs located in deep, critical, or relatively inaccessible cerebral locations.« less

  2. Magnetic navigation facilitates percutaneous coronary intervention for complex lesions.

    PubMed

    Sandhu, Gurpreet S; Sanon, Saurabh; Holmes, David R; Gulati, Rajiv; Brilakis, Emmanouil S; Lennon, Ryan J; Rihal, Charanjit S

    2014-10-01

    We sought to determine the utility of a magnetic navigation system (MNS) in treating a variety of coronary artery lesions including those that could not be revascularized with standard percutaneous coronary intervention (PCI). MNS may add value in the treatment of tortuous arteries and bifurcation lesions; however its widespread adoption has lagged because of cost and a lack of clear advantage over conventional PCI. We performed a retrospective analysis to determine whether MNS improved procedural success for highly complex lesions. One hundred and forty-eight patients underwent treatment with MNS at Mayo Clinic, Rochester. Clinical data, angiographic and procedural characteristics, lesion crossing success and outcomes were reviewed. Overall 133 patients underwent successful revascularization with 87% (143) of 164 lesions crossed using MNS alone. Another six lesions required a combination of MNS and conventional devices resulting in overall success of 91% (149/164). Eighteen complex lesions had previously failed PCI and 12 (67%) were successfully treated with MNS. Success after failed PCI was higher (88%) when a frequent user operated MNS, but occasional users also noted incremental success (30%). Twenty-five chronic total occlusions were included amongst these 164 lesions, with observed antegrade MNS lesion crossing rates of 78% for regular and 14% for occasional users. MNS is a useful adjunct to performance of PCI. This specialized technology has a clear learning curve and can facilitate treatment of highly complex lesions. © 2013 Wiley Periodicals, Inc.

  3. Economic evaluation of drug-eluting stents in coronary angioplasty.

    PubMed

    Santos, Ricardo; Pereira, Hélder

    2005-11-01

    Coronary angioplasty has revolutionized the treatment of coronary artery disease, from the first balloon angioplasty to the current era of drug-eluting stents (DES), which were developed to eliminate the bare metal stent's (BMS) Achilles' heel, restenosis. DES have an extremely low restenosis rate but are significantly more expensive and need more prolonged dual antiplatelet therapy. Restenosis has a generally benign prognosis and is not associated with higher mortality or major adverse cardiovascular events, which has limited the penetration of DES, whose only advantage is the reduction of restenosis. Economic evaluation of DES is therefore of paramount importance for assessing their appropriate use. In randomized trials in which they are compared with BMS, economic evaluation is advantageous for DES, with good cost-effectiveness ratios for both cost per quality-adjusted life year (QALY) and cost per revascularization avoided. However, these trials have two major limitations--the angiographic follow-up protocol and selection of patients with lower risk--and so their results do not accurately reflect reality. Other studies with unselected populations and cost-effectiveness models show that there is an economic advantage in the use of DES in groups with higher risk of restenosis, but not for the whole population undergoing angioplasty. Use of DES will be more appropriate if we can identify populations with a higher likelihood of restenosis, because these are the patients that will benefit most from their use and in whom they will be economically advantageous.

  4. Standardized End Point Definitions for Coronary Intervention Trials: The Academic Research Consortium-2 Consensus Document.

    PubMed

    Garcia-Garcia, Hector M; McFadden, Eugène P; Farb, Andrew; Mehran, Roxana; Stone, Gregg W; Spertus, John; Onuma, Yoshinobu; Morel, Marie-Angèle; van Es, Gerrit-Anne; Zuckerman, Bram; Fearon, William F; Taggart, David; Kappetein, Arie-Pieter; Krucoff, Mitchell W; Vranckx, Pascal; Windecker, Stephan; Cutlip, Donald; Serruys, Patrick W

    2018-06-14

    The Academic Research Consortium (ARC)-2 initiative revisited the clinical and angiographic end point definitions in coronary device trials, proposed in 2007, to make them more suitable for use in clinical trials that include increasingly complex lesion and patient populations and incorporate novel devices such as bioresorbable vascular scaffolds. In addition, recommendations for the incorporation of patient-related outcomes in clinical trials are proposed. Academic Research Consortium-2 is a collaborative effort between academic research organizations in the United States and Europe, device manufacturers, and European, US, and Asian regulatory bodies. Several in-person meetings were held to discuss the changes that have occurred in the device landscape and in clinical trials and regulatory pathways in the last decade. The consensus-based end point definitions in this document are endorsed by the stakeholders of this document and strongly advocated for clinical trial purposes. This Academic Research Consortium-2 document provides further standardization of end point definitions for coronary device trials, incorporating advances in technology and knowledge. Their use will aid interpretation of trial outcomes and comparison among studies, thus facilitating the evaluation of the safety and effectiveness of these devices.

  5. Influence of collaterals on the left ventricular end-diastolic pressure and serum NT-proBNP levels in patients with coronary chronic total occlusion.

    PubMed

    Samadov, Fuad; Yesildag, Osman; Sari, Ibrahim; Atas, Halil; Akhundova, Aysel; Basaran, Yelda

    2017-06-01

    Although numerous studies have shown the protective effects of the well-developed coronary collaterals on left ventricular functions, the relationship between collateral grade and left ventricular end diastolic pressure has not been studied in chronic total occlusion patients. Also, there are conflicting data on the effect of collaterals on NT-proBNP levels. The aim of our study was to evaluate the relationship between coronary collateral circulation and left ventricular end diastolic pressure and NT-proBNP levels in chronic total occlusion patients. Study group was retrospectively selected from the patients who had undergone coronary angiography at our hospital between June 2011 and March 2013. Clinical, biochemical, angiographic and hemodynamic data of 199 consecutive patients having at least one totally occluded major epicardial coronary artery were evaluated. Coronary collateral circulation was graded according to Rentrop classification. While Rentrop grade 3 was defined as well-developed, all the remaining collateral grades were regarded as poor collaterals. Overall 87 patients were found to have good collaterals and 112 patients had poor collaterals. There was no significant difference between the patients with well- or poorly developed coronary collaterals with regard to left ventricular end diastolic pressure (16.84 ± 5.40 mmHg vs 16.10 ± 6.09, respectively, p  = 0,632) and log NT-proBNP (2.46 ± 0.58 vs 2.59 ± 0.76, respectively, p  = 0,335). In patients with coronary chronic total occlusion even well-developed coronary collaterals are not capable of protecting the rise of left ventricular end diastolic pressure and NT-proBNP levels which are reliable markers of the left ventricular dysfunction.

  6. The presence of African American race predicts improvement in coronary endothelial function after supplementary L-arginine.

    PubMed

    Houghton, Jan L; Philbin, Edward F; Strogatz, David S; Torosoff, Mikhail T; Fein, Steven A; Kuhner, Patricia A; Smith, Vivienne E; Carr, Albert A

    2002-04-17

    The purpose of our study was to determine if the presence of African American ethnicity modulates improvement in coronary vascular endothelial function after supplementary L-arginine. Endothelial dysfunction is an early stage in the development of coronary atherosclerosis and has been implicated in the pathogenesis of hypertension and cardiomyopathy. Amelioration of endothelial dysfunction has been demonstrated in patients with established coronary atherosclerosis or with risk factors in response to infusion of L-arginine, the precursor of nitric oxide. Racial and gender patterns in L-arginine responsiveness have not, heretofore, been studied. Invasive testing of coronary artery and microvascular reactivity in response to graded intracoronary infusions of acetylcholine (ACh) +/- L-arginine was carried out in 33 matched pairs of African American and white subjects with no angiographic coronary artery disease. Pairs were matched for age, gender, indexed left ventricular mass, body mass index and low-density lipoprotein cholesterol. In addition to the matching parameters, there were no significant differences in peak coronary blood flow (CBF) response to intracoronary adenosine or in the peak CBF response to ACh before L-arginine infusion. However, absolute percentile improvement in CBF response to ACh infusion after L-arginine, as compared with before, was significantly greater among African Americans as a group (45 +/- 10% vs. 4 +/- 6%, p = 0.0016) and after partitioning by gender. The mechanism of this increase was mediated through further reduction in coronary microvascular resistance. L-arginine infusion also resulted in greater epicardial dilator response after ACh among African Americans. We conclude that intracoronary infusion of L-arginine provides significantly greater augmentation of endothelium-dependent vascular relaxation in those of African American ethnicity when compared with matched white subjects drawn from a cohort electively referred for coronary

  7. Lack of association between the Glu298Asp polymorphism of endothelial nitric oxide synthase and slow coronary flow in the Turkish population

    PubMed Central

    Caglayan, Ahmet Okay; Kalay, Nihat; Saatci, Cetin; Yalcın, Arif; Akalın, Hilal; Dundar, Munis

    2009-01-01

    BACKGROUND: Coronary endothelial dysfunction plays an important pathogenetic role in patients with slow coronary flow (SCF). No data exist regarding the possible contribution of the Glu298Asp polymorphism genotype of the endothelial nitric oxide synthase (eNOS) gene to human SCF in the literature. OBJECTIVE: To investigate the association between SCF and the Glu298Asp polymorphism of the eNOS gene. METHODS: The study population consisted of 85 consecutive patients. The patient group included 66 patients with angiographically proven normal coronary arteries with SCF, and 19 subjects with normal coronary arteries with no SCF. The thrombolysis in myocardial infarction frame count was used for the diagnosis of SCF. The Glu298Asp polymorphism was determined by polymerase chain reaction and restriction fragment length polymorphism. RESULTS: The baseline characteristics were similar between the two groups, except for high-density lipoprotein cholesterol, which was higher in the SCF group than in the controls. The genotype distribution of Glu298Asp was as follows: GG 26%, GT 56% and TT 12%, where G is guanine and T is thymine. There was no difference in the frequency of the various genotypes or the alleles in patients with SCF versus normal controls. CONCLUSIONS: The Glu298Asp polymorphism genotype of the eNOS gene is not a risk factor for SCF in the present study population. PMID:19279989

  8. Titanium-nitride-oxide-coated coronary stents: insights from the available evidence.

    PubMed

    Karjalainen, Pasi P; Nammas, Wail

    2017-06-01

    Coating of stent surface with a biocompatible material is suggested to improve stent safety profile. A proprietary process was developed to coat titanium-nitride-oxide on the stent surface, based on plasma technology that uses the nano-synthesis of gas and metal. Preclinical in vitro and in vivo investigation confirmed blood compatibility of titanium (nitride-) oxide films. Titanium-nitride-oxide-coated stents demonstrated a better angiographic outcome, compared with bare-metal stents at mid-term follow-up; however, they failed to achieve non-inferiority for angiographic outcome versus second-generation drug-eluting stents. Observational studies showed adequate clinical outcome at mid-term follow-up. Non-randomized studies showed an outcome of titanium-nitride-oxide-coated stents comparable to - or better than - first-generation drug-eluting stents at long-term follow-up. Two randomized controlled trials demonstrated comparable efficacy outcome, and a better safety outcome of titanium-nitride-oxide-coated stents versus drug-eluting stents at long-term follow-up. Evaluation by optical coherence tomography at mid-term follow-up revealed better neointimal strut coverage associated with titanium-nitride-oxide-coated stents versus drug-eluting stents; yet, neointimal hyperplasia thickness was greater. Key messages Stents coated with titanium-nitride-oxide demonstrated biocompatibility in preclinical studies: they inhibit platelet and fibrin deposition, and reduce neointimal growth. In observational and non-randomized studies, titanium-nitride-oxide-coated stents were associated with adequate safety and efficacy outcome. In randomized trials of patients with acute coronary syndrome, titanium-nitride-oxide-coated stents were associated with a better safety outcome, compared with drug-eluting stents; efficacy outcome was comparable.

  9. Biomechanical Impact of Wrong Positioning of a Dedicated Stent for Coronary Bifurcations: A Virtual Bench Testing Study.

    PubMed

    Chiastra, Claudio; Grundeken, Maik J; Collet, Carlos; Wu, Wei; Wykrzykowska, Joanna J; Pennati, Giancarlo; Dubini, Gabriele; Migliavacca, Francesco

    2018-05-17

    The treatment of coronary bifurcations is challenging for interventional cardiologists. The Tryton stent (Tryton Medical, Inc., USA) is one of the few devices specifically designed for coronary bifurcations that underwent large clinical trials. Although the manufacturer provides specific recommendations to position the stent in the bifurcation side branch (SB) according to four radio-opaque markers under angiographic guidance, wrong device positioning may accidentally occur. In this study, the virtual bench testing approach was used to investigate the impact of wrong positioning of the Tryton stent in coronary bifurcations in terms of geometrical and biomechanical criteria. A finite element model of the left anterior descending/first diagonal coronary bifurcation was created with a 45° distal angle and realistic lumen diameters. A validated model of the Tryton stent mounted on stepped delivery balloon was used. All steps of the Tryton deployment sequence were simulated. Three Tryton positions, namely 'proximal', 'recommended', and 'distal' positions, obtained by progressively implanting the stent more distally in the SB, were compared. The 'recommended' case exhibited the lowest ostial area stenosis (44.8 vs. 74.3% ('proximal') and 51.5% ('distal')), the highest diameter at the SB ostium (2.81 vs. 2.70 mm ('proximal') and 2.54 mm ('distal')), low stent malapposition (9.9 vs. 16.3% ('proximal') and 8.5% ('distal')), and the lowest peak wall stress (0.37 vs. 2.20 MPa ('proximal') and 0.71 MPa ('distal')). In conclusion, the study shows that a 'recommended' Tryton stent positioning may be required for optimal clinical results.

  10. Correlation study on waist circumference-triglyceride (WT) index and coronary artery scores in patients with coronary heart disease.

    PubMed

    Yang, R-F; Liu, X-Y; Lin, Z; Zhang, G

    2015-01-01

    Coronary disease is analyzed through common lipid profiles, but these analyses fail to account for residual risk due to abdominal weight and elevated TG levels. We aimed to investigate the relationship between the waist circumference × triglyceride index (WT index) and the Coronary Artery Score (CAS) in patients with coronary heart disease. 346 patients in our Cardiology Department were recruited from September 2007 to August 2011 and divided into two groups according to whether the patients presented with metabolic syndrome. We performed coronary angiography using the standard Judkins method. The severity of coronary artery stenosis and the CAS were calculated and analyzed with a computerized quantitative analysis system. The signs index, which includes the body mass index (BMI), waist circumference, hip circumference, waist-hip-ratio, and waist-height-ratio, the blood glucose and blood lipid index of all the patients were collected and used to calculate the WT index (waist circumference x triglyceride index. We performed a correlative analysis with age, gender, body mass index, blood glucose and blood lipid, blood pressure and other risk indicators of all patients as the dependent variables and the CAS as the independent variable. We show that the CAS is positively correlated to the WT index. Several lipid profiles and waist circumference were significantly associated with the CAS. The WT index is correlated to the CAS and is a good predictor for the development of coronary artery disease; it can be applied in the clinic for early intervention in populations at risk for coronary heart disease.

  11. Comparative utility of gated myocardial perfusion imaging and transthoracic coronary flow reserve for the assessment of coronary artery disease in patients with left bundle branch block.

    PubMed

    Pavlovic, Smiljana; Sobic-Saranovic, Dragana; Djordjevic-Dikic, Ana; Beleslin, Branko; Stepanovic, Jelena; Artiko, Vera; Giga, Vojislav; Petrasinovic, Zorica; Ostojic, Miodrag; Vujisic-Tesic, Bosiljka; Obradovic, Vladimir

    2010-04-01

    To compare the diagnostic utility of gated single-photon emission computed tomography (SPECT) methoxy isobutyl isonitrile (MIBI) myocardial perfusion imaging and transthoracic Doppler echocardiography (TTDE) coronary flow reserve (CFR) to coronary angiography for detecting coronary artery disease (CAD) in patients with left bundle branch block (LBBB). Forty-three patients with complete LBBB and an intermediate pretest probability for CAD underwent dipyridamole stress TTDE and gated SPECT MIBI during the same session and coronary angiography within a month. The parameters of myocardial perfusion (summed stress score, summed difference scores) regional wall function (wall motion score, wall thickening score) and ejection fraction were derived using the 17-segment model and 4D-MSPECT software. TTDE variables included peak flow velocity at rest and during hyperemia in left anterior descending artery (LAD), based on which CFR was calculated (normal>2). Perfusion ischemic scores were significantly higher in group 1 with angiographic evidence of greater than 50% LAD stenosis compared with group 2 with less than 50% LAD stenosis (summed stress score 12.4+/-5.5 vs. 8.3+/-3.5, P<0.05, summed difference score 3.7+/-1.2 vs. 1.1+/-0.3, P<0.01, respectively). Left ventricular regional wall function and ejection fraction were not different between the two groups. CFR was significantly lower in group 1 than in group 2 (1.65+/-0.21 vs. 2.31+/-0.28, P<0.001). Gated SPECT MIBI and CFR had similar sensitivity (88 vs. 88%), specificity (80 vs. 84%), and accuracy (84 vs. 86%) for detecting CAD in patients with LBBB. The agreement between the two methods was 85%. Our results show comparable diagnostic utility and high agreement between gated SPECT MIBI perfusion imaging and TTDE CFR assessment for detecting CAD in patients with LBBB. The advantage of gated SPECT MIBI over TTDE CFR measurements is the ability to assess the perfusion abnormalities in multiple vascular territories during

  12. The Relationship Between Genetic Variations of the Cholesteryl Ester Transfer Protein Gene and Coronary Artery Disease in Turkish Subjects

    PubMed Central

    Gundogdu, Fuat; Gurlertop, Yekta; Pirim, Ibrahim; Sevimli, Serdar; Dogan, Hasan; Arslan, Sakir; Aksoy, Hulya; Karakelloglu, Sule; Senocak, Huseyin

    2009-01-01

    Objective Although the relationship between cholesteryl ester transfer protein (CETP) and cholesterol metabolism has been characterized in recent years, the effect of CETP genetic variants associated with coronary artery disease (CAD) is still unclear. Therefore, we investigated the association between CETP gene polymorphism and levels of lipid in patients with CAD. Materials and Methods We conducted a case-control study that included 194 unrelated subjects who underwent coronary angiography for suspected ischemic heart disease. This group was divided into 96 patients with angiographically documented CAD and 98 subjects (individuals matched for age and gender) without angiographically documented CAD (CAD-free subjects), all of whom were studied to examine the genotypic distribution of the CETP gene polymorphism in CAD. Genotyping was performed via polymerase chain reaction. Results Of the 96 patients with CAD, 38 (40%) were B1B1, 42 (44%) B1B2 and 16 (16%) B2B2, compared with the control subjects, of which 35 (36%) were B1B1, 44 (45%) B1B2 and 19 (19%) B2B2. There were no significant differences between patients with CAD and control subjects in the distribution of the CETP gene polymorphism. Patients with the B1B1 genotype had lower high-density lipoprotein-cholesterol (HDL-C) and higher triglyceride (TG) levels than patients with the B2B2 genotype (p<0.05). In addition, among control subjects HDL-C levels were significantly higher in subjects with the B2B2 genotype than in subjects with the B1B1 genotype (p<0.01). Conclusion Our results suggest that genetic variations of the CTEP gene may be responsible for low HDL-C levels but may not be considered as a risk factor for CAD in the Turkish population. PMID:25610061

  13. Gender differences in risk profile and outcome of Middle Eastern patients undergoing percutaneous coronary intervention.

    PubMed

    Jarrah, Mohamad I; Hammoudeh, Ayman J; Al-Natour, Dalal B; Khader, Yousef S; Tabbalat, Ramzi A; Alhaddad, Imad A; Kullab, Susan M

    2017-02-01

    To determine the gender differences in cardiovascular risk profile and outcomes among patients undergoing percutaneous coronary intervention (PCI). Methods: In a prospective multicenter study of consecutive Middle Eastern patients managed with PCI from January 2013 to February 2014 in 12 tertiary care centers in Amman and Irbid, Jordan. Clinical and coronary angiographic features, and major cardiovascular events were assessed for both genders from hospital stay to 1 year. Results: Women comprised 20.6% of 2426 enrolled patients, were older (mean age 62.9 years versus 57.2 years), had higher prevalence of hypertension (81% versus 57%), diabetes (66% versus 44%), dyslipidemia (58% versus 46%), and obesity (44% versus 25%) compared with men, p less than 0.001. The PCI for ST-segment elevation myocardial infarction was indicated for fewer women than men (23% versus 33%; p=0.001). Prevalence of single or multi-vessel coronary artery disease was similar in women and men. More women than men had major bleeding during hospitalization (2.2% versus 0.6%; p=0.003) and at one year (2.5% versus 0.9%; p=0.007). There were no significant differences between women and men in mortality (3.1% versus 1.7%) or stent thrombosis (2.1% versus 1.8%) at 1 year. Conclusion: Middle Eastern women undergoing PCI had worse baseline risk profile compared with men.Except for major bleeding, no gender differences in the incidence of major adverse cardiovascular events were demonstrated.

  14. Is high high-density lipoprotein cholesterol beneficial for premature coronary heart disease? A meta-analysis.

    PubMed

    Shahid, Murtuza; Sun, Run L; Liu, Yu; Bao, Jin L; Huang, Can X; Liao, Yu; Zhou, Shu X; Wang, Jing F; Zhang, Yu L

    2016-05-01

    To clarify the association between premature coronary heart disease of patients ≤55 years and high-density lipoprotein cholesterol (HDL-C) plasma levels. Searches were performed between 2002 and 2013 using PubMed, Web of Science, Science Direct, and Google Scholar. The original articles selected published premature coronary heart disease diagnosed by World Health Organization criteria or via angiograph both in males and females ≤55 years and with plasma HDL-C levels in both the case and control groups. The 'related articles' function and manual searches of the related references was used to broaden the search. The Newcastle-Ottawa Quality Assessment Scale was used to assess the quality of papers. Standard mean difference with 95% confidence interval was used as a measure of the association between HDL and premature coronary heart disease, after pooling data across trials in a random effect model. Sensitivity and subgroup analyses were used to explore sources of heterogeneity and the effect of potential confounders. The influences of publication year, sample size and district were assessed by meta-regression. STATA (version 11.0) was used to conduct all statistical analyses. Only 13 case-control studies met the criteria, which included 1775 patients and 1989 controls. The Newcastle-Ottawa Quality Assessment Scale score was about 5-7. A strong association was identified between HDL-C and premature coronary heart disease. The premature coronary heart disease patients had lower levels of HDL-C compared with the controls: standard mean difference = -0.48, 95% confidence interval = -0.71 to -0.26, p < 0.001, pheterogeneity < 0.001. By meta-regression and subgroup analysis, we found publication year might be the source of heterogeneity, but not the main reason for heterogeneity. After removing the heterogeneity of outlier studies, the significant association between low HDL-C levels and premature coronary heart disease was still retained. Low plasma

  15. Quantitative Cardiac Positron Emission Tomography: The Time Is Coming!

    PubMed Central

    Sciagrà, Roberto

    2012-01-01

    In the last 20 years, the use of positron emission tomography (PET) has grown dramatically because of its oncological applications, and PET facilities are now easily accessible. At the same time, various groups have explored the specific advantages of PET in heart disease and demonstrated the major diagnostic and prognostic role of quantitation in cardiac PET. Nowadays, different approaches for the measurement of myocardial blood flow (MBF) have been developed and implemented in user-friendly programs. There is large evidence that MBF at rest and under stress together with the calculation of coronary flow reserve are able to improve the detection and prognostication of coronary artery disease. Moreover, quantitative PET makes possible to assess the presence of microvascular dysfunction, which is involved in various cardiac diseases, including the early stages of coronary atherosclerosis, hypertrophic and dilated cardiomyopathy, and hypertensive heart disease. Therefore, it is probably time to consider the routine use of quantitative cardiac PET and to work for defining its place in the clinical scenario of modern cardiology. PMID:24278760

  16. Acute myocardial infarction in very young adults: A clinical presentation, risk factors, hospital outcome index, and their angiographic characteristics in North India-AMIYA Study.

    PubMed

    Sinha, Santosh Kumar; Krishna, Vinay; Thakur, Ramesh; Kumar, Ashutosh; Mishra, Vikas; Jha, Mukesh Jitendra; Singh, Karandeep; Sachan, Mohit; Sinha, Rupesh; Asif, Mohammad; Afdaali, Nasar; Mohan Varma, Chandra

    2017-03-01

    India is currently in the fourth stage of epidemiological transitions where cardiovascular disease is the leading cause of mortality and morbidity. Purpose of the present study was to assess the risk factors, clinical presentation, angiographic profile including severity, and in-hospital outcome of very young adults (aged ≤ 30 years) with first acute myocardial infarction (AMI). Total of 1,116 consecutive patients with ST-segment elevation acute myocardial infarction (STEMI) were studied between March 2013 and February 2015 at LPS Institute of Cardiology, Kanpur, Uttar Pradesh, India. Mean age of the patients was 26.3 years. Risk factors were smoking (78.5%), family history of premature coronary artery disease (CAD) (46.8%), obesity (39.1%), physical inactivity (38.7%) and stressful life events (29.6%). The most common symptom and presentation was chest pain and anterior wall myocardial infarction (AWMI) in 94.8% and 58.8%, respectively. About 80.6% of patients had obstructive CAD with single vessel disease (57.6%), double-vessel disease (12.9%) and left main involvement (3.2%). Left anterior descending (LAD) was commonest culprit artery (58.1%) followed by right coronary artery in 28.2%. In-hospital mortality was 2.8%. Percutaneous coronary intervention was performed in 71.6% of patients. Median number and length of stent were 1.18 and 28 ± 16 mm, respectively. AMI in very young adult occurred most commonly in male. Smoking was the most common risk factor. AWMI owing to LAD artery involvement was the most common presentation. Mean time of presentation after symptom onset was 16.9 hours. In contrast to western population, it is characterised by earlier onset, delayed presentation, more severity, diffuse disease, and more morbidity but with favourable in-hospital mortality.

  17. Expression of tumour necrosis factor alpha and accumulation of fibronectin in coronary artery restenotic lesions retrieved by atherectomy.

    PubMed Central

    Clausell, N.; de Lima, V. C.; Molossi, S.; Liu, P.; Turley, E.; Gotlieb, A. I.; Adelman, A. G.; Rabinovitch, M.

    1995-01-01

    BACKGROUND--The formation of coronary artery neointima experimentally induced in piglets after cardiac transplantation is related to an immune-inflammatory reaction associated with increased expression of T cells and inflammatory mediators (tumour necrosis factor alpha and interleukin 1 beta) and upregulation of fibronectin. In vivo blockade of tumour necrosis factor alpha in rabbits after cardiac transplantation results in reduced neointimal formation. The objective of this study was to investigate the hypothesis that coronary restenosis after atherectomy or percutaneous balloon angioplasty is associated with a similar inflammatory cascade initiated by mechanical injury. METHODS--Specimens taken at coronary atherectomy were analysed from 16 patients. Nine had had the procedure performed twice, firstly, to remove a primary lesion, and secondly, to remove a restenotic lesion. Seven had percutaneous balloon angioplasty after removal of restenotic tissue. Coronary atherectomy specimens were analysed by immunohistochemistry for the presence of T cells, macrophages, major histocompatibility complex II, interleukin 1 beta, tumour necrosis factor alpha, fibronectin, and the receptor for hyaluronan mediated motility. RESULTS--The groups were clinically and angiographically similar with equivalent lumens before and after atherectomy. Restenotic lesions had increased expression of tumour necrosis factor alpha and fibronectin compared with the primary lesions (P < 0.05 for both). There was also a trend towards a greater number of T cells and increased expression of interleukin 1 beta. CONCLUSIONS--Restenosis is associated with increased expression of tumour necrosis factor alpha and fibronectin, suggesting that an immune-inflammatory reaction probably contributes to neointimal formation and may represent a form of wound healing and repair secondary to mechanical injury. Images PMID:7626352

  18. First-in-man study evaluating the safety and efficacy of a second generation biodegradable polymer sirolimus-eluting stent in the treatment of patients with de novo coronary lesions: clinical, Angiographic, and OCT outcomes of CREDIT-1.

    PubMed

    Wang, Geng; Sun, Zhongwei; Jin, Quanmin; Xu, Kai; Li, Yi; Wang, Xiaozeng; Ma, Yingyan; Liu, Haiwei; Zhao, Xin; Wang, Bin; Deng, Jie; Guan, Shaoyi; Ge, Meiling; Wang, Xiaoyan; Xu, Bo; Han, Yaling

    2015-03-01

    To evaluate the preliminary safety and efficacy of the EXCEL II stent system. Although the first biodegradable polymer drug-eluting stent (BP-DES), EXCEL, was launched nearly a decade ago, in-stent restenosis and stent thrombosis remain pertinent clinical problems in practice. A new cobalt-chromium BP-DES EXCEL II has been developed with the aim of improving stent safety and efficacy. Forty-five patients with single de novo native coronary lesions were enrolled and randomized to two groups in a 2:1 ratio, the 4-month follow-up group (n = 30) and the 12-month follow-up group (n = 15). All patients underwent percutaneous coronary intervention (PCI) with the EXCEL II stent system. Quantitative coronary angiography (QCA) and optical coherence tomography (OCT) were used to assess coronary vasculature at the designated 4- or 12-month follow-up. The primary outcome was major adverse cardiac events (MACE) at 30 days post-PCI. No MACE, thrombotic events, or target lesion failure was found in the 45 patients during the 12-month follow-up. There was no significant difference (P > 0.05) between the two groups in terms of in-stent and in-segment late lumen loss (LLL). No in-stent and in-segment restenosis was found in either group. At follow-up, the ratio of >10% uncovered struts per lesion was 26.67% in the 4-month group and 0% in the 12-month group (P < 0.05). Neointimal coverage in the 12-month group was significantly better than in the 4-month group (98.58% vs. 93.51%, P < 0.01). This first-in-man study demonstrates promising feasibility, safety, and efficacy of EXCEL II stents. These stents were found to have rapid endothelialization and low LLL rates at 4 and 12 months after implantation. © 2015 Wiley Periodicals, Inc.

  19. Impact of vasomotion type on prognosis of coronary artery spasm induced by acetylcholine provocation test of left coronary artery.

    PubMed

    Lee, Eun Mi; Choi, Man Ho; Seo, Hong Seog; Kim, Hyun Ki; Kim, Nam-Ho; Choi, Cheol Ung; Kim, Jin Won; Lim, Hong Euy; Kim, Eung Ju; Rha, Seung-Woon; Park, Chang Gyu; Oh, Dong Joo

    2017-02-01

    The impact of vasomotion types on long-term clinical outcomes in patients with coronary artery spasm (CAS) induced by the acetylcholine provocation test (ACH-test) remains unclear. We evaluated 4644 consecutive patients with typical resting chest pain (CP), but no angiographically significant coronary artery lesion (<50% stenosis), who underwent an ACH-test. According to their vasomotor response, patients were categorized into four types: normal vasomotion (no CP, no ischemic electrocardiographic changes, and no vasoconstriction), microvascular spasm (CP with <75% vasoconstriction but with CP relief after nitroglycerin infusion), epicardial spasm (CP with ≥75% vasoconstriction), and ACH-test inconclusive (vasoconstriction and/or electrocardiographic changes, but no CP). We investigated CP recurrence requiring follow-up angiography and major adverse cardiovascular events (MACEs) during 5 years. CP recurred in 7.9% of patients and was more frequent in abnormal vasomotion types (normal vasomotion, microvascular spasm, epicardial spasm, and inconclusive type: 5.4%, 9.8%, 10.9%, and 8.2%, respectively, log-rank p = 0.009). In multivariate analysis adjusted for medication use after the ACH-test, vasomotion subtype was not an independent predictor, whereas male sex, fixed lesion on baseline angiography, and medications including calcium channel blockers (CCBs), nitrates, and statins were independent positive predictors for recurrent CP. Alcohol consumption at the initial interview was a negative predictor. MACEs were observed in 1.6%, and the incidence was similar among subtypes (p = 0.421). Recurrent CP and long-term outcomes are independent of vasomotion subtypes, but long-term use of CCBs, nitrates, and statins is a significant predictor for recurrent CP. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Everolimus-Eluting Stents or Bypass Surgery for Left Main Coronary Artery Disease.

    PubMed

    Stone, Gregg W; Sabik, Joseph F; Serruys, Patrick W; Simonton, Charles A; Généreux, Philippe; Puskas, John; Kandzari, David E; Morice, Marie-Claude; Lembo, Nicholas; Brown, W Morris; Taggart, David P; Banning, Adrian; Merkely, Béla; Horkay, Ferenc; Boonstra, Piet W; van Boven, Ad J; Ungi, Imre; Bogáts, Gabor; Mansour, Samer; Noiseux, Nicolas; Sabaté, Manel; Pomar, José; Hickey, Mark; Gershlick, Anthony; Buszman, Pawel; Bochenek, Andrzej; Schampaert, Erick; Pagé, Pierre; Dressler, Ovidiu; Kosmidou, Ioanna; Mehran, Roxana; Pocock, Stuart J; Kappetein, A Pieter

    2016-12-08

    Patients with obstructive left main coronary artery disease are usually treated with coronary-artery bypass grafting (CABG). Randomized trials have suggested that drug-eluting stents may be an acceptable alternative to CABG in selected patients with left main coronary disease. We randomly assigned 1905 eligible patients with left main coronary artery disease of low or intermediate anatomical complexity to undergo either percutaneous coronary intervention (PCI) with fluoropolymer-based cobalt-chromium everolimus-eluting stents (PCI group, 948 patients) or CABG (CABG group, 957 patients). Anatomic complexity was assessed at the sites and defined by a Synergy between Percutaneous Coronary Intervention with Taxus and Cardiac Surgery (SYNTAX) score of 32 or lower (the SYNTAX score reflects a comprehensive angiographic assessment of the coronary vasculature, with 0 as the lowest score and higher scores [no upper limit] indicating more complex coronary anatomy). The primary end point was the rate of a composite of death from any cause, stroke, or myocardial infarction at 3 years, and the trial was powered for noninferiority testing of the primary end point (noninferiority margin, 4.2 percentage points). Major secondary end points included the rate of a composite of death from any cause, stroke, or myocardial infarction at 30 days and the rate of a composite of death, stroke, myocardial infarction, or ischemia-driven revascularization at 3 years. Event rates were based on Kaplan-Meier estimates in time-to-first-event analyses. At 3 years, a primary end-point event had occurred in 15.4% of the patients in the PCI group and in 14.7% of the patients in the CABG group (difference, 0.7 percentage points; upper 97.5% confidence limit, 4.0 percentage points; P=0.02 for noninferiority; hazard ratio, 1.00; 95% confidence interval, 0.79 to 1.26; P=0.98 for superiority). The secondary end-point event of death, stroke, or myocardial infarction at 30 days occurred in 4.9% of the

  1. Soluble urokinase plasminogen activator receptor level is an independent predictor of the presence and severity of coronary artery disease and of future adverse events.

    PubMed

    Eapen, Danny J; Manocha, Pankaj; Ghasemzadeh, Nima; Ghasemzedah, Nima; Patel, Riyaz S; Al Kassem, Hatem; Hammadah, Muhammad; Veledar, Emir; Le, Ngoc-Anh; Pielak, Tomasz; Thorball, Christian W; Velegraki, Aristea; Kremastinos, Dimitrios T; Lerakis, Stamatios; Sperling, Laurence; Quyyumi, Arshed A

    2014-10-23

    Soluble urokinase plasminogen activator receptor (suPAR) is an emerging inflammatory and immune biomarker. Whether suPAR level predicts the presence and the severity of coronary artery disease (CAD), and of incident death and myocardial infarction (MI) in subjects with suspected CAD, is unknown. We measured plasma suPAR levels in 3367 subjects (67% with CAD) recruited in the Emory Cardiovascular Biobank and followed them for adverse cardiovascular (CV) outcomes of death and MI over a mean 2.1±1.1 years. Presence of angiographic CAD (≥50% stenosis in ≥1 coronary artery) and its severity were quantitated using the Gensini score. Cox's proportional hazard survival and discrimination analyses were performed with models adjusted for established CV risk factors and C-reactive protein levels. Elevated suPAR levels were independently associated with the presence of CAD (P<0.0001) and its severity (P<0.0001). A plasma suPAR level ≥3.5 ng/mL (cutoff by Youden's index) predicted future risk of MI (hazard ratio [HR]=3.2; P<0.0001), cardiac death (HR=2.62; P<0.0001), and the combined endpoint of death and MI (HR=1.9; P<0.0001), even after adjustment of covariates. The C-statistic for a model based on traditional risk factors was improved from 0.72 to 0.74 (P=0.008) with the addition of suPAR. Elevated levels of plasma suPAR are associated with the presence and severity of CAD and are independent predictors of death and MI in patients with suspected or known CAD. © 2014 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  2. Soluble Urokinase Plasminogen Activator Receptor Level Is an Independent Predictor of the Presence and Severity of Coronary Artery Disease and of Future Adverse Events

    PubMed Central

    Eapen, Danny J.; Manocha, Pankaj; Ghasemzedah, Nima; Patel, Riyaz S.; Al Kassem, Hatem; Hammadah, Muhammad; Veledar, Emir; Le, Ngoc‐Anh; Pielak, Tomasz; Thorball, Christian W.; Velegraki, Aristea; Kremastinos, Dimitrios T.; Lerakis, Stamatios; Sperling, Laurence; Quyyumi, Arshed A.

    2014-01-01

    Introduction Soluble urokinase plasminogen activator receptor (suPAR) is an emerging inflammatory and immune biomarker. Whether suPAR level predicts the presence and the severity of coronary artery disease (CAD), and of incident death and myocardial infarction (MI) in subjects with suspected CAD, is unknown. Methods and Results We measured plasma suPAR levels in 3367 subjects (67% with CAD) recruited in the Emory Cardiovascular Biobank and followed them for adverse cardiovascular (CV) outcomes of death and MI over a mean 2.1±1.1 years. Presence of angiographic CAD (≥50% stenosis in ≥1 coronary artery) and its severity were quantitated using the Gensini score. Cox's proportional hazard survival and discrimination analyses were performed with models adjusted for established CV risk factors and C‐reactive protein levels. Elevated suPAR levels were independently associated with the presence of CAD (P<0.0001) and its severity (P<0.0001). A plasma suPAR level ≥3.5 ng/mL (cutoff by Youden's index) predicted future risk of MI (hazard ratio [HR]=3.2; P<0.0001), cardiac death (HR=2.62; P<0.0001), and the combined endpoint of death and MI (HR=1.9; P<0.0001), even after adjustment of covariates. The C‐statistic for a model based on traditional risk factors was improved from 0.72 to 0.74 (P=0.008) with the addition of suPAR. Conclusion Elevated levels of plasma suPAR are associated with the presence and severity of CAD and are independent predictors of death and MI in patients with suspected or known CAD. PMID:25341887

  3. Angiographic and Interventional Management for a Esophagopericardial Fistula

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Keng, E-mail: zjwukeng@hotmail.com; You, Qiong, E-mail: qiong_you@yahoo.cn; He, Song-Jian

    2013-06-19

    We reported a case of a 78-year-old patient with esophagopericardial fistula who was referred for angiographic and interventional management. Emergent implantation of the esophageal stent could not lengthen or even save the patient’s life. One week later, the patient died of multiple organ failure, which was probably from formation of granulation tissue and stent migration. Therefore, if the inflammatory to the esophagopericardial fistula had been better controlled initially, and the implantation of the esophageal stent delayed, our patient would have survived.

  4. A multicenter post-marketing evaluation of the Elixir DESolve® Novolimus-eluting bioresorbable coronary scaffold system: First results from the DESolve PMCF study.

    PubMed

    Nef, Holger; Wiebe, Jens; Boeder, Niklas; Dörr, Oliver; Bauer, Timm; Hauptmann, Karl-Eugen; Latib, Azeem; Colombo, Antonio; Fischer, Dieter; Rudolph, Tanja; Foin, Nicolas; Richardt, Gert; Hamm, Christian

    2018-03-06

    To date, experience with bioresorbable scaffolds (BRS) that elute agents other than everolimus is limited. Thus, a post-marketing clinical follow-up study was conducted to evaluate the continued safety and effectiveness of the DESolve® NOVOLIMUS™ Eluting BRS as treatment for patients with stable coronary artery disease. The DESolve BRS combines a poly-l-lactide-based backbone with a biodegradable polylactide-based polymer and Novolimus, a macrocyclic lactone mTOR inhibitor. One hundred and two patients (mean age 62 years, 77.5% male) were enrolled at 10 European sites. Comparison of baseline and post-procedural angiographic assessment was performed, and a device-oriented composite endpoint (comprising cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularization) and rate of scaffold thrombosis at 12 months were examined. The device was successfully delivered and deployed in 98.2% (107/109) of the lesions, with two failures to cross the lesion. A total of 100 patients (109 lesions) were treated with a DESolve BRS. Post-procedural angiographic assessment indicated an in-scaffold acute gain of 1.54 ± 0.44 mm, with a reduction in % diameter stenosis from 61.00 ± 11.29 to 12.69 ± 0.44. At 12 months, the device-oriented composite endpoint had occurred in 3.0% (3/100) of patients, with 1.0% (1/100) experiencing scaffold thrombosis and myocardial infarction and 3.0% (3/100) undergoing target lesion revascularization. There were no cardiac deaths. Results through 12 months indicate that the DESolve BRS is a safe and effective treatment for coronary lesions, though larger, long-term prospective studies are needed. © 2018 Wiley Periodicals, Inc.

  5. Combined use of high-sensitivity C-reactive protein and apolipoprotein B/apolipoprotein A-1 ratio prior to elective coronary angiography and oral glucose tolerance tests.

    PubMed

    Wen, Zhu-zhi; Geng, Deng-feng; Luo, Jin-gang; Wang, Jing-feng

    2011-11-01

    The study aimed to investigate the predictive value of the combination of high-sensitivity C-reactive protein (hs-CRP) and apolipoprotein B (apoB)/apoA-1 ratio for the outcomes of coronary angiography (CAG), echocardiography and oral glucose tolerance tests (OGTTs). Hs-CRP, apoB, apoA-1, and the profiles of CAG, echocardiography and OGTTs as well as traditional risk factors were measured in 1757 cardiology patients. Hs-CRP or apoB/apoA-1 ratio was significantly correlated with the presence and severity of angiographic profiles, the levels of left ventricular (LV) ejection fraction, LV mass and LV mass index, and the presence of abnormal glucose metabolism. The combination of hs-CRP and apoB/apoA-1 ratio had greater correlation with abnormal glucose metabolism than its individual components in patients with normal fasting glucose, and was an independent predictor for coronary artery disease. The combination of hs-CRP and apoB/apoA-1 ratio may be a strong predictor for coronary artery disease and abnormal glucose metabolism. Copyright © 2011 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  6. The Practice Pattern of Percutaneous Coronary Intervention in Korea: Based on Year 2014 Cohort of Korean Percutaneous Coronary Intervention (K-PCI) Registry.

    PubMed

    Gwon, Hyeon-Cheol; Jeon, Dong Woon; Kang, Hyun-Jae; Jang, Jae-Sik; Park, Duk-Woo; Shin, Dong-Ho; Moon, Keon-Woong; Kim, Jung-Sun; Kim, Juhan; Bae, Jang-Whan; Hur, Seung-Ho; Kim, Byung Ok; Choi, Donghoon; Han, Kyoo-Rok; Kim, Hyo-Soo

    2017-05-01

    Appropriate use criteria (AUC) was developed to improve the quality of percutaneous coronary intervention (PCI). However, these criteria should consider the current practice pattern in the country where they are being applied. The algorithm for the Korean PCI practice pattern (KP3) was developed by modifying the United States-derived AUC in expert consensus meetings. KP3 class A was defined as any strategy with evidence from randomized trials that was more conservative for PCI than medical therapy or coronary artery bypass graft (CABG). Class C was defined as any strategy with less evidence from randomized trials and more aggressive for PCI than medical therapy or CABG. Class B was defined as a strategy that was partly class A and partly class C. We applied the KP3 classification system to the Korean PCI registry. The KP3 class A was noted in 67.7% of patients, class B in 28.8%, and class C in 3.5%. The median proportion of class C cases per center was 2.0%. The distribution of KP3 classes varied significantly depending on clinical and angiographic characteristics. The proportion of KP3 class C cases per center was not significantly dependent on PCI volume, but rather on the percentage of ACS cases in each center. We report the current PCI practice pattern by applying the new KP3 classification in a nationwide PCI registry. The results should be interpreted carefully with due regard for the complex relationships between the determining variables and the healthcare system in Korea.

  7. Analysis of simulated angiographic procedures. Part 2: extracting efficiency data from audio and video recordings.

    PubMed

    Duncan, James R; Kline, Benjamin; Glaiberman, Craig B

    2007-04-01

    To create and test methods of extracting efficiency data from recordings of simulated renal stent procedures. Task analysis was performed and used to design a standardized testing protocol. Five experienced angiographers then performed 16 renal stent simulations using the Simbionix AngioMentor angiographic simulator. Audio and video recordings of these simulations were captured from multiple vantage points. The recordings were synchronized and compiled. A series of efficiency metrics (procedure time, contrast volume, and tool use) were then extracted from the recordings. The intraobserver and interobserver variability of these individual metrics was also assessed. The metrics were converted to costs and aggregated to determine the fixed and variable costs of a procedure segment or the entire procedure. Task analysis and pilot testing led to a standardized testing protocol suitable for performance assessment. Task analysis also identified seven checkpoints that divided the renal stent simulations into six segments. Efficiency metrics for these different segments were extracted from the recordings and showed excellent intra- and interobserver correlations. Analysis of the individual and aggregated efficiency metrics demonstrated large differences between segments as well as between different angiographers. These differences persisted when efficiency was expressed as either total or variable costs. Task analysis facilitated both protocol development and data analysis. Efficiency metrics were readily extracted from recordings of simulated procedures. Aggregating the metrics and dividing the procedure into segments revealed potential insights that could be easily overlooked because the simulator currently does not attempt to aggregate the metrics and only provides data derived from the entire procedure. The data indicate that analysis of simulated angiographic procedures will be a powerful method of assessing performance in interventional radiology.

  8. Myocardial Infarction as a Complication of Bronchial Artery Embolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Labbé, Hugo, E-mail: hugo.labbe.1@ulaval.ca; Bordeleau, Simon; Drouin, Christine

    Bronchial artery embolization is now a common treatment for massive pulmonary hemoptysis if flexible bronchoscopy at the bedside failed to control the bleeding. Complications of this technique range from benign chest pain to devastating neurological impairments. We report the case of a 41-year-old man who developed an ST elevation myocardial infarction during bronchial artery embolization, presumably because of coronary embolism by injected particles. In this patient who had no previously known coronary artery disease, we retrospectively found a communication between the left bronchial artery and the circumflex coronary artery. This fistula was not visible on the initial angiographic view andmore » likely opened because of the hemodynamic changes resulting from the embolization. This case advocates for careful search for bronchial-to-coronary arterial fistulas and the need for repeated angiographic views during embolization procedures.« less

  9. Additive prognostic value of the SYNTAX score over GRACE, TIMI, ZWOLLE, CADILLAC and PAMI risk scores in patients with acute ST-segment elevation myocardial infarction treated by primary percutaneous coronary intervention.

    PubMed

    Brkovic, Voin; Dobric, Milan; Beleslin, Branko; Giga, Vojislav; Vukcevic, Vladan; Stojkovic, Sinisa; Stankovic, Goran; Nedeljkovic, Milan A; Orlic, Dejan; Tomasevic, Miloje; Stepanovic, Jelena; Ostojic, Miodrag

    2013-08-01

    This study evaluated additive prognostic value of the SYNTAX score over GRACE, TIMI, ZWOLLE, CADILLAC and PAMI risk scores in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (pPCI). All six scores were calculated in 209 consecutive STEMI patients undergoing pPCI. Primary end-point was the major adverse cardiovascular event (MACE--composite of cardiovascular mortality, non-fatal myocardial infarction and stroke); secondary end point was cardiovascular mortality. Patients were stratified according to the SYNTAX score tertiles (≤12; between 12 and 19.5; >19.5). The median follow-up was 20 months. Rates of MACE and cardiovascular mortality were highest in the upper tertile of the SYNTAX score (p < 0.001 and p = 0.003, respectively). SYNTAX score was independent multivariable predictor of MACE and cardiovascular mortality when added to GRACE, TIMI, ZWOLLE, and PAMI risk scores. However, the SYNTAX score did not improve the Cox regression models of MACE and cardiovascular mortality when added to the CADILLAC score. The SYNTAX score has predictive value for MACE and cardiovascular mortality in patients with STEMI undergoing primary PCI. Furthermore, SYNTAX score improves prognostic performance of well-established GRACE, TIMI, ZWOLLE and PAMI clinical scores, but not the CADILLAC risk score. Therefore, long-term survival in patients after STEMI depends less on detailed angiographical characterization of coronary lesions, but more on clinical characteristics, myocardial function and basic angiographic findings as provided by the CADILLAC score.

  10. Mono-Energy Coronary Angiography with a Compact Synchrotron Source

    NASA Astrophysics Data System (ADS)

    Eggl, Elena; Mechlem, Korbinian; Braig, Eva; Kulpe, Stephanie; Dierolf, Martin; Günther, Benedikt; Achterhold, Klaus; Herzen, Julia; Gleich, Bernhard; Rummeny, Ernst; Noёl, Peter B.; Pfeiffer, Franz; Muenzel, Daniela

    2017-02-01

    X-ray coronary angiography is an invaluable tool for the diagnosis of coronary artery disease. However, the use of iodine-based contrast media can be contraindicated for patients who present with chronic renal insufficiency or with severe iodine allergy. These patients could benefit from a reduced contrast agent concentration, possibly achieved through application of a mono-energetic x-ray beam. While large-scale synchrotrons are impractical for daily clinical use, the technology of compact synchrotron sources strongly advanced during the last decade. Here we present a quantitative analysis of the benefits a compact synchrotron source can offer in coronary angiography. Simulated projection data from quasi-mono-energetic and conventional x-ray tube spectra is used for a CNR comparison. Results show that compact synchrotron spectra would allow for a significant reduction of contrast media. Experimentally, we demonstrate the feasibility of coronary angiography at the Munich Compact Light Source, the first commercial installation of a compact synchrotron source.

  11. Stress-only myocardial perfusion scintigraphy: a prospective study on the accuracy and observer agreement with quantitative coronary angiography as the gold standard.

    PubMed

    Ejlersen, June A; May, Ole; Mortensen, Jesper; Nielsen, Gitte L; Lauridsen, Jeppe F; Allan, Johansen

    2017-11-01

    Patients with normal stress perfusion have an excellent prognosis. Prospective studies on the diagnostic accuracy of stress-only scans with contemporary, independent examinations as gold standards are lacking. A total of 109 patients with typical angina and no previous coronary artery disease underwent a 2-day stress (exercise)/rest, gated, and attenuation-corrected (AC), 99m-technetium-sestamibi perfusion study, followed by invasive coronary angiography. The stress datasets were evaluated twice by four physicians with two different training levels (expert and novice): familiar and unfamiliar with AC. The two experts also made a consensus reading of the integrated stress-rest datasets. The consensus reading and quantitative data from the invasive coronary angiography were applied as reference methods. The sensitivity/specificity were 0.92-1.00/0.73-0.90 (reference: expert consensus reading), 0.93-0.96/0.63-0.82 (reference: ≥1 stenosis>70%), and 0.75-0.88/0.70-0.88 (reference: ≥1 stenosis>50%). The four readers showed a high and fairly equal sensitivity independent of their familiarity with AC. The expert familiar with AC had the highest specificity independent of the reference method. The intraobserver and interobserver agreements on the stress-only readings were good (readers without AC experience) to excellent (readers with AC experience). AC stress-only images yielded a high sensitivity independent of the training level and experience with AC of the nuclear physician, whereas the specificity correlated positively with both. Interobserver and intraobserver agreements tended to be the best for physicians with AC experience.

  12. Quantitative Myocardial Perfusion Imaging Versus Visual Analysis in Diagnosing Myocardial Ischemia: A CE-MARC Substudy.

    PubMed

    Biglands, John D; Ibraheem, Montasir; Magee, Derek R; Radjenovic, Aleksandra; Plein, Sven; Greenwood, John P

    2018-05-01

    This study sought to compare the diagnostic accuracy of visual and quantitative analyses of myocardial perfusion cardiovascular magnetic resonance against a reference standard of quantitative coronary angiography. Visual analysis of perfusion cardiovascular magnetic resonance studies for assessing myocardial perfusion has been shown to have high diagnostic accuracy for coronary artery disease. However, only a few small studies have assessed the diagnostic accuracy of quantitative myocardial perfusion. This retrospective study included 128 patients randomly selected from the CE-MARC (Clinical Evaluation of Magnetic Resonance Imaging in Coronary Heart Disease) study population such that the distribution of risk factors and disease status was proportionate to the full population. Visual analysis results of cardiovascular magnetic resonance perfusion images, by consensus of 2 expert readers, were taken from the original study reports. Quantitative myocardial blood flow estimates were obtained using Fermi-constrained deconvolution. The reference standard for myocardial ischemia was a quantitative coronary x-ray angiogram stenosis severity of ≥70% diameter in any coronary artery of >2 mm diameter, or ≥50% in the left main stem. Diagnostic performance was calculated using receiver-operating characteristic curve analysis. The area under the curve for visual analysis was 0.88 (95% confidence interval: 0.81 to 0.95) with a sensitivity of 81.0% (95% confidence interval: 69.1% to 92.8%) and specificity of 86.0% (95% confidence interval: 78.7% to 93.4%). For quantitative stress myocardial blood flow the area under the curve was 0.89 (95% confidence interval: 0.83 to 0.96) with a sensitivity of 87.5% (95% confidence interval: 77.3% to 97.7%) and specificity of 84.5% (95% confidence interval: 76.8% to 92.3%). There was no statistically significant difference between the diagnostic performance of quantitative and visual analyses (p = 0.72). Incorporating rest myocardial

  13. Association of High Density Lipoprotein with Platelet to Lymphocyte and Neutrophil to Lymphocyte Ratios in Coronary Artery Disease Patients

    PubMed Central

    Prajapati, Jayesh H.; Sahoo, Sibasis; Nikam, Tushar; Shah, Komal H.; Maheriya, Bhumika; Parmar, Meena

    2014-01-01

    Background. We aimed to evaluate a relationship between platelet-lymphocyte ratio (PLR) and neutrophil-lymphocyte ratio (NLR) with high density lipoprotein (HDL) cholesterol levels in coronary artery disease (CAD) patients. Methods. A total of 354 patients with angiographically confirmed coronary blockages were enrolled in the study. Hematological indices and lipid profiling data of all the patients were collected. Results. We have observed significant association between HDL and PLR (P = 0.008) and NLR (P = 0.009); however no significant relationship was obtained with HDL and isolated platelet (P = 0.488), neutrophil (P = 0.407), and lymphocyte (P = 0.952) counts in CAD patients. The association was subjected to gender specific variation as in males PLR (P = 0.024) and NLR (P = 0.03) were highly elevated in low HDL patients, whereas in females the elevation could not reach the statistically significant level. The PLR (217.47 versus 190.3; P = 0.01) and NLR (6.33 versus 5.10; P = 0.01) were significantly higher among the patients with acute coronary syndrome. In young patients the PLR (P = 0.007) and NLR (P = 0.001) were inversely associated with HDL, whereas in older population only NLR (P = 0.05) had showed a significant association. Conclusion. We conclude that PLR and NLR are significantly elevated in CAD patients having low HDL levels. PMID:25478231

  14. Association of high density lipoprotein with platelet to lymphocyte and neutrophil to lymphocyte ratios in coronary artery disease patients.

    PubMed

    Prajapati, Jayesh H; Sahoo, Sibasis; Nikam, Tushar; Shah, Komal H; Maheriya, Bhumika; Parmar, Meena

    2014-01-01

    Background. We aimed to evaluate a relationship between platelet-lymphocyte ratio (PLR) and neutrophil-lymphocyte ratio (NLR) with high density lipoprotein (HDL) cholesterol levels in coronary artery disease (CAD) patients. Methods. A total of 354 patients with angiographically confirmed coronary blockages were enrolled in the study. Hematological indices and lipid profiling data of all the patients were collected. Results. We have observed significant association between HDL and PLR (P = 0.008) and NLR (P = 0.009); however no significant relationship was obtained with HDL and isolated platelet (P = 0.488), neutrophil (P = 0.407), and lymphocyte (P = 0.952) counts in CAD patients. The association was subjected to gender specific variation as in males PLR (P = 0.024) and NLR (P = 0.03) were highly elevated in low HDL patients, whereas in females the elevation could not reach the statistically significant level. The PLR (217.47 versus 190.3; P = 0.01) and NLR (6.33 versus 5.10; P = 0.01) were significantly higher among the patients with acute coronary syndrome. In young patients the PLR (P = 0.007) and NLR (P = 0.001) were inversely associated with HDL, whereas in older population only NLR (P = 0.05) had showed a significant association. Conclusion. We conclude that PLR and NLR are significantly elevated in CAD patients having low HDL levels.

  15. Accuracy of MSCT Coronary Angiography with 64 Row CT Scanner—Facing the Facts

    PubMed Central

    Wehrschuetz, M.; Wehrschuetz, E.; Schuchlenz, H.; Schaffler, G.

    2010-01-01

    Improvements in multislice computed tomography (MSCT) angiography of the coronary vessels have enabled the minimally invasive detection of coronary artery stenoses, while quantitative coronary angiography (QCA) is the accepted reference standard for evaluation thereof. Sixteen-slice MSCT showed promising diagnostic accuracy in detecting coronary artery stenoses haemodynamically and the subsequent introduction of 64-slice scanners promised excellent and fast results for coronary artery studies. This prompted us to evaluate the diagnostic accuracy, sensitivity, specificity, and the negative und positive predictive value of 64-slice MSCT in the detection of haemodynamically significant coronary artery stenoses. Thirty-seven consecutive subjects with suspected coronary artery disease were evaluated with MSCT angiography and the results compared with QCA. All vessels were considered for the assessment of significant coronary artery stenosis (diameter reduction ≥ 50%). Thirteen patients (35%) were identified as having significant coronary artery stenoses on QCA with 6.3% (35/555) affected segments. None of the coronary segments were excluded from analysis. Overall sensitivity for classifying stenoses of 64-slice MSCT was 69%, specificity was 92%, positive predictive value was 38% and negative predictive value was 98%. The interobserver variability for detection of significant lesions had a k-value of 0.43. Sixty-four-slice MSCT offers the diagnostic potential to detect coronary artery disease, to quantify haemodynamically significant coronary artery stenoses and to avoid unnecessary invasive coronary artery examinations. PMID:20567636

  16. Incidence and predictors of silent embolic cerebral infarction following diagnostic coronary angiography.

    PubMed

    Kim, In-Cheol; Hur, Seung-Ho; Park, Nam-Hee; Jun, Dong-Hwan; Cho, Yun-Kyeong; Nam, Chang-Wook; Kim, Hyungseop; Han, Seong-Wook; Choi, Sae-Young; Kim, Yoon-Nyun; Kim, Kwon-Bae

    2011-04-14

    Coronary angiography (CAG) is an invasive diagnostic procedure, which could lead to procedure related complications. One of the well known post-procedural complications is cerebral embolic infarction with or without symptoms. Silent embolic cerebral infarction (SECI) has clinical significance because it can progress to a decline in cognitive function and increase the risk of dementia in the long term. The aim of this study was to detect the incidence and predictors of SECI after diagnostic CAG using diffusion-weighted magnetic resonance imaging (DW-MRI). A total of 197 patients with coronary artery disease who underwent DW-MRI for evaluation of intracranial vasculopathy before coronary artery bypass graft surgery were retrospectively enrolled in the present study. DW-MRI was performed within 48 h after diagnostic CAG. SECI was diagnosed as presence of focal bright high signal intensity in DW-MRI. Patients were divided into groups according to presence/absence of SECI (+ SECI vs. - SECI, respectively). The clinical and angiographic characteristics were analyzed and independent predictors were evaluated. Of the 197 patients, SECI occurred in 20 patients (10.2%) after diagnostic CAG. Age, female gender, frequency of underlying atrial fibrillation, extent of coronary disease, and fluoroscopic time during diagnostic CAG were not different between the + SECI and - SECI groups. Left ventricular ejection fraction was significantly lower in the + SECI group than in the - SECI group (45.9 ± 8.5% vs. 51.4 ± 13.1%, p=0.014) and performance rate of internal mammary artery (IMA) angiography was significantly higher in the + SECI group compared with the - SECI group (85% vs. 37.2%, p<0.001). By multivariate analysis, performing IMA angiography was the only predictor of SECI (OR=14.642; 95% CI=3.201 to 66.980, p=0.001). The incidence of SECI after diagnostic CAG was not infrequent. Diagnostic CAG with IMA angiography may increase the risk of SECI. Copyright © 2009 Elsevier

  17. Symptom-limited exercise testing causes sustained diastolic dysfunction in patients with coronary disease and low effort tolerance.

    PubMed

    Fragasso, G; Benti, R; Sciammarella, M; Rossetti, E; Savi, A; Gerundini, P; Chierchia, S L

    1991-05-01

    Exercise stress testing is routinely used for the noninvasive assessment of coronary artery disease and is considered a safe procedure. However, the provocation of severe ischemia might potentially cause delayed recovery of myocardial function. To investigate the possibility that maximal exercise testing could induce prolonged impairment of left ventricular function, 15 patients with angiographically proved coronary disease and 9 age-matched control subjects with atypical chest pain and normal coronary arteries were studied. Radionuclide ventriculography was performed at rest, at peak exercise, during recovery and 2 and 7 days after exercise. Ejection fraction, peak filling and peak emptying rates and left ventricular wall motion were analyzed. All control subjects had a normal exercise test at maximal work loads and improved left ventricular function on exercise. Patients developed 1 mm ST depression at 217 +/- 161 s at a work load of 70 +/- 30 W and a rate-pressure product of 18,530 +/- 4,465 mm Hg x beats/min. Although exercise was discontinued when angina or equivalent symptoms occurred, in all patients diagnostic ST depression (greater than or equal to 1 mm) developed much earlier than symptoms. Predictably, at peak exercise patients showed a decrease in ejection fraction and peak emptying and filling rates. Ejection fraction and peak emptying rate normalized within the recovery period, whereas peak filling rate remained depressed throughout recovery (p less than 0.002) and was still reduced 2 days after exercise (p less than 0.02). In conclusion, in patients with severe impairement of coronary flow reserve, maximal exercise may cause sustained impairement of diastolic function.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. PAI-1 4G/5G polymorphism and plasma levels association in patients with coronary artery disease.

    PubMed

    Lima, Luciana Moreira; Carvalho, Maria das Graças; Fonseca Neto, Cirilo Pereira; Garcia, José Carlos Faria; Sousa, Marinez Oliveira

    2011-12-01

    Type-1 plasminogen activator inhibitor (PAI-1) 4G/5G polymorphism may influence the PAI-1 expression. High plasma levels of PAI-1 are associated with coronary artery disease (CAD). This study investigated the influence of PAI-1 4G/5G polymorphism on plasma PAI-1 levels and its association with CAD assessed by coronary angiography. Blood sample of 35 individuals with angiographically normal coronary arteries, 31 individuals presenting mild/moderate atheromatosis, 57 individuals presenting severe atheromatosis and 38 healthy individuals (controls) were evaluated. In patients and controls, the PAI-1 4G/5G polymorphism was determined by PCR amplification using allele-specific primers. Plasma PAI-1 levels were quantified by ELISA assay (American Diagnostica). No difference was found between groups regarding age, gender and body mass index. Plasma PAI-1 levels and 4G/4G genotype frequency were significantly higher in the severe atheromatosis group compared to the other groups (p<0.001). Furthermore, patients with 4G/4G genotype (r=0.28, p<0.001) had significantly higher plasma PAI-1 levels than those with 5G/5G genotype (r=0.02, p=0.4511). In addition, in a multiple logistic regression model, adjusted for all the other variables, PAI-1 was observed to be independently associated with CAD > 70% (p<0.001). The most important finding of this study was the association between 4G/4G genotype, high plasma PAI-1 levels and coronary stenosis higher than 70% in Brazilian individuals. Whether high plasma PAI-1 levels are a decisive factor for atherosclerosis worsening or it is a consequence remains to be established.

  19. Angiographic outcomes following stenting or coronary artery bypass surgery of the left main coronary artery: fifteen-month outcomes from the synergy between PCI with TAXUS express and cardiac surgery left main angiographic substudy (SYNTAX-LE MANS).

    PubMed

    Morice, Marie-Claude; Feldman, Ted E E; Mack, Michael J; Ståhle, Elisabeth; Holmes, David R; Colombo, Antonio; Morel, Marie-Angèle; van den Brand, Marcel; Serruys, Patrick W; Mohr, Friedrich; Carrié, Didier; Fournial, Gérard; James, Stefan; Leadley, Katrin; Dawkins, Keith D; Kappetein, A Pieter

    2011-10-30

    The SYNTAX-LE MANS substudy prospectively evaluated 15-month angiographic and clinical outcomes in patients with treated left main (LM) disease. In the SYNTAX trial, 1,800 patients with three-vessel and/or LM disease were randomised to either CABG or PCI; of these, 271 LM patients were prospectively assigned to receive a 15-month angiogram. The primary endpoint for the CABG arm was the ratio of ≥50% to <100% obstructed/occluded grafts bypassing LM lesions to the number placed. The primary endpoint for the PCI arm was the proportion of patients with ≤50% diameter stenosis ('patent' stents) of treated LM lesions. Per protocol, no formal comparison between CABG and PCI arms was intended based on the differing primary endpoints. Available 15-month angiograms were analysed for 114 CABG and 149 PCI patients. At 15 months, 9.9% (26/263) of CABG grafts were 100% occluded and an additional 5.7% (15/263) were ≥50% to <100% occluded. Overall, 27.2% (31/114) of patients had ≥1 obstructed/occluded graft. The 15-month CABG MACCE rate was 8.8% (10/114) and MACCE at 15 months was not significantly associated with graft obstruction/occlusion (p=0.85). In the PCI arm, 92.4% (134/145) of patients had ≤50% diameter LM stenosis at 15 months (89.7% [87/97] distal LM lesions and 97.9% [47/48] non-distal LM lesions). The 15-month PCI MACCE rate was 12.8% (20/156) and this was significantly associated with lack of stent patency at 15 months (p<0.001), mainly due to repeat revascularisation. At 15 months, 15.6% (41/263) of grafts were at least 50% obstructed but this was not significantly associated with MACCE; 92.4% (134/145) of patients had stents that remained patent at 15 months, and stent restenosis was significantly associated with MACCE, predominantly due to revascularisation.

  20. Influence of Adaptive Statistical Iterative Reconstruction on coronary plaque analysis in coronary computed tomography angiography.

    PubMed

    Precht, Helle; Kitslaar, Pieter H; Broersen, Alexander; Dijkstra, Jouke; Gerke, Oke; Thygesen, Jesper; Egstrup, Kenneth; Lambrechtsen, Jess

    The purpose of this study was to study the effect of iterative reconstruction (IR) software on quantitative plaque measurements in coronary computed tomography angiography (CCTA). Thirty patients with a three clinical risk factors for coronary artery disease (CAD) had one CCTA performed. Images were reconstructed using FBP, 30% and 60% adaptive statistical IR (ASIR). Coronary plaque analysis was performed as per patient and per vessel (LM, LAD, CX and RCA) measurements. Lumen and vessel volumes and plaque burden measurements were based on automatic detected contours in each reconstruction. Lumen and plaque intensity measurements and HU based plaque characterization were based on corrected contours copied to each reconstruction. No significant changes between FBP and 30% ASIR were found except for lumen- (-2.53 HU) and plaque intensities (-1.28 HU). Between FBP and 60% ASIR the change in total volume showed an increase of 0.94%, 4.36% and 2.01% for lumen, plaque and vessel, respectively. The change in total plaque burden between FBP and 60% ASIR was 0.76%. Lumen and plaque intensities decreased between FBP and 60% ASIR with -9.90 HU and -1.97 HU, respectively. The total plaque component volume changes were all small with a maximum change of -1.13% of necrotic core between FBP and 60% ASIR. Quantitative plaque measurements only showed modest differences between FBP and the 60% ASIR level. Differences were increased lumen-, vessel- and plaque volumes, decreased lumen- and plaque intensities and a small percentage change in the individual plaque component volumes. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  1. Standardized End Point Definitions for Coronary Intervention Trials: The Academic Research Consortium-2 Consensus Document.

    PubMed

    Garcia-Garcia, Hector M; McFadden, Eugène P; Farb, Andrew; Mehran, Roxana; Stone, Gregg W; Spertus, John; Onuma, Yoshinobu; Morel, Marie-Angèle; van Es, Gerrit-Anne; Zuckerman, Bram; Fearon, William F; Taggart, David; Kappetein, Arie-Pieter; Krucoff, Mitchell W; Vranckx, Pascal; Windecker, Stephan; Cutlip, Donald; Serruys, Patrick W

    2018-06-12

    The Academic Research Consortium (ARC)-2 initiative revisited the clinical and angiographic end point definitions in coronary device trials, proposed in 2007, to make them more suitable for use in clinical trials that include increasingly complex lesion and patient populations and incorporate novel devices such as bioresorbable vascular scaffolds. In addition, recommendations for the incorporation of patient-related outcomes in clinical trials are proposed. Academic Research Consortium-2 is a collaborative effort between academic research organizations in the United States and Europe, device manufacturers, and European, US, and Asian regulatory bodies. Several in-person meetings were held to discuss the changes that have occurred in the device landscape and in clinical trials and regulatory pathways in the last decade. The consensus-based end point definitions in this document are endorsed by the stakeholders of this document and strongly advocated for clinical trial purposes. This Academic Research Consortium-2 document provides further standardization of end point definitions for coronary device trials, incorporating advances in technology and knowledge. Their use will aid interpretation of trial outcomes and comparison among studies, thus facilitating the evaluation of the safety and effectiveness of these devices. © 2018 American Heart Association, Inc., and European Society of Cardiology.

  2. Incidence, Clinical Presentation, and Predictors of Clinical Restenosis in Coronary Bioresorbable Scaffolds.

    PubMed

    Polimeni, Alberto; Weissner, Melissa; Schochlow, Katharina; Ullrich, Helen; Indolfi, Ciro; Dijkstra, Jouke; Anadol, Remzi; Münzel, Thomas; Gori, Tommaso

    2017-09-25

    The aim of this study was to describe the incidence and clinical characteristics, including intracoronary imaging features, of clinical restenosis in bioresorbable coronary scaffolds (BRS). Further, the authors searched for clinical and procedural predictors of scaffold restenosis (ScR) and report on the clinical outcomes after treatment of ScR in a cohort of consecutive all-comer patients. Data from randomized controlled trials demonstrate a higher rate of target lesion failure in patients treated with BRS as compared with those treated with metal drug-eluting stents. Although in-scaffold thrombosis has been thoroughly investigated, there are little data available on the incidence and characteristics of ScR. A total of 657 consecutive patients (age 63 ± 12 years, 79% men, 21% diabetics, 67% acute coronary syndrome) who received a total of 883 BRS for the treatment of coronary artery stenoses between May 2012 and January 2015 were enrolled in a retrospective registry. During the median follow-up of 1,076 days (interquartile range: 762 to 1,206 days), a total of 49 cases of ScR were found in 41 patients (Kaplan-Meier incidence: 2.4%, 6.0%, and 9.0% at 12-, 24-, and 36-month follow-up, respectively). ScR presented as stable angina or as incidental finding in 73% of the cases. The angiographic pattern was complex (type II to IV) in 55% of the ScR lesions. The neointima was homogeneous with high signal intensity in all but 3 cases at optical coherence tomography. Prior revascularization (hazard ratio [HR]: 2.7; 95% confidence interval [CI]: 1.5 to 5.1; p = 0.002), diabetes (HR: 2.9; 95%CI: 1.5 to 5.4; p = 0.001), lesion types B2 or C (HR: 2.8; 95% CI: 1.5 to 5.4; p = 0.002), and implantation technique (HR: 0.3; 95% CI: 0.1 to 0.6; p = 0.001) emerged as independent predictors of ScR. Oversizing (HR: 6.29; 95% CI: 2.4 to 16.4), undersizing (HR: 5.15; 95% CI: 1.99 to 13.30), and a residual stenosis >27% (HR: 8.9; 95% CI: 3.6 to 21.8) were associated with an

  3. A comparison of clinical features of coronary artery spasm with and without thyrotoxicosis.

    PubMed

    Lee, Soo Youn; Yu, Cheol Woong; Choi, Young Jin; Choi, Rak Kyeong; Park, Jin Sik; Lee, Hyun Jong; Kim, Je Sang; Jang, Ho Jun; Jang, Duck Hyun; Chae, Myung Joon; Shim, Won Heum; Ro, Young Moo

    2014-03-01

    Several reports have suggested that thyrotoxicosis may induce severe coronary artery spasm (CAS). However, there are few data regarding the differences in clinical characteristics of CAS with and without thyrotoxicosis. The aim of our study is to compare the clinical features of CAS with and without thyrotoxicosis. We evaluated 430 consecutive patients with CAS [patients with thyrotoxicosis (N=32, group I) and those without (N=398, group II)] at a single institute between January 2001 and June 2011. We compared clinical presentations, angiographic findings, and adverse outcomes (a composite outcome of cardiac death, myocardial infarction, or rehospitalization due to cardiac cause) of both groups. There was higher incidence of acute myocardial infarction at initial presentation in group I (15.6 vs. 5.8%, P=0.04). CAS with thyrotoxicosis was more diffuse (59.4 vs. 39.3%, P=0.03), more medically intractable (9.4 vs. 0%, P=0.001), and more frequently involved the left main vessel (25.0 vs.0.8%, P=0.001) than CAS without thyrotoxicosis. During the follow-up period (median 43 months), there were no significant differences between the two groups in terms of the risk of adverse outcomes (hazard ratio for CAS with thyrotoxicosis, 1.029; 95% confidence interval, 0.347-3.054). Clinical and angiographic presentations of CAS with thyrotoxicosis were more severe than CAS without thyrotoxicosis, but clinical outcomes were similar in both groups. Optimal vasodilator therapy is essential for the management of CAS with thyrotoxicosis. Thyroid function test should be mandatory for all patients with CAS.

  4. Effect of sex difference in clinical presentation (stable coronary artery disease vs unstable angina pectoris or non-ST-elevation myocardial infarction vs ST-elevation myocardial infarction) on 2-year outcomes in patients undergoing percutaneous coronary intervention.

    PubMed

    Tang, Xiao-Fang; Song, Ying; Xu, Jing-Jing; Ma, Yuan-Liang; Zhang, Jia-Hui; Yao, Yi; He, Chen; Wang, Huan-Huan; Jiang, Ping; Jiang, Lin; Liu, Ru; Gao, Zhan; Zhao, Xue-Yan; Qiao, Shu-Bin; Xu, Bo; Yang, Yue-Jin; Gao, Run-Lin; Yuan, Jin-Qing

    2018-02-01

    To determine whether there is a difference in 2-year prognosis among patients across the spectrum of coronary artery disease undergoing percutaneous coronary intervention (PCI). We analyzed all consecutive patients undergoing PCI at a single center from 1/1-12/31/2013. Clinical presentations were compared between sexes according to baseline clinical, angiographic, and procedural characteristics and 2-year (mean 730 ± 30-day) outcomes. We grouped 10 724 consecutive patients based on sex and clinical presentation. Among patients with ST-elevation myocardial infarction (STEMI), rates of all-cause death (6.7% vs 1.4%) and cardiac death (3.8% vs 1.1%) were significantly higher in women than in men (P < 0.05), but these rates did not differ between men and women with stable coronary artery disease (SCAD) and non-ST-elevation acute coronary syndrome ((NSTE-ACS). Incidence of major bleeding was greater than in men only in those women presenting with ACS. After multivariable adjustment, female sex was not an independent predictor of outcomes in STEMI (hazard ratio [HR] for all-cause death: 1.33, 95% confidence interval [CI]:0.52-3.38; P = 0.55; HR for cardiac death: 0.69, 95%CI: 0.23-2.09, P = 0.51], but was still an independent predictor of bleeding in STEMI (HR: 3.53, 95%CI: 1.26-9.91, P = 0.017). Among STEMI patients, women had worse 2-year mortality after PCI therapy, but female sex was not an independent predictor of mortality after adjustment for baseline characteristics. In STEMI patients, women were at higher bleeding risk than men after PCI, even after multivariable adjustment. © 2017, Wiley Periodicals, Inc.

  5. Prognostic significance of normal quantitative planar thallium-201 stress scintigraphy in patients with chest pain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wackers, F.J.; Russo, D.J.; Russo, D.

    The prognostic significance of normal quantitative planar thallium-201 stress scintigraphy was evaluated in patients with a chest pain syndrome. The prevalence of cardiac events during follow-up was related to the pretest (that is, before stress scintigraphy) likelihood of coronary artery disease determined on the basis of symptoms, age, sex and stress electrocardiography. In a consecutive series of 344 patients who had adequate thallium-201 stress scintigrams, 95 had unequivocally normal studies by quantitative analysis. The pretest likelihood of coronary artery disease in the 95 patients had a bimodal distribution. During a mean follow-up period of 22 +/- 3 months, no patientmore » died. Three patients (3%) had a cardiac event: two of these patients (pretest likelihood of coronary artery disease 54 and 94%) had a nonfatal myocardial infarction 8 and 22 months, respectively, after stress scintigraphy, and one patient (pretest likelihood 98%) underwent percutaneous transluminal coronary angioplasty 16 months after stress scintigraphy for persisting anginal complaints. Three patients were lost to follow-up; all three had a low pretest likelihood of coronary artery disease. It is concluded that patients with chest pain and normal findings on quantitative thallium-201 scintigraphy have an excellent prognosis. Cardiac events are rare (infarction rate 1% per year) and occur in patients with a moderate to high pretest likelihood of coronary artery disease.« less

  6. Dark chocolate improves coronary vasomotion and reduces platelet reactivity.

    PubMed

    Flammer, Andreas J; Hermann, Frank; Sudano, Isabella; Spieker, Lukas; Hermann, Matthias; Cooper, Karen A; Serafini, Mauro; Lüscher, Thomas F; Ruschitzka, Frank; Noll, Georg; Corti, Roberto

    2007-11-20

    Dark chocolate has potent antioxidant properties. Coronary atherosclerosis is promoted by impaired endothelial function and increased platelet activation. Traditional risk factors, high oxidative stress, and reduced antioxidant defenses play a crucial role in the pathogenesis of atherosclerosis, particularly in transplanted hearts. Thus, flavonoid-rich dark chocolate holds the potential to have a beneficial impact on graft atherosclerosis. We assessed the effect of flavonoid-rich dark chocolate compared with cocoa-free control chocolate on coronary vascular and platelet function in 22 heart transplant recipients in a double-blind, randomized study. Coronary vasomotion was assessed with quantitative coronary angiography and cold pressor testing before and 2 hours after ingestion of 40 g of dark (70% cocoa) chocolate or control chocolate, respectively. Two hours after ingestion of flavonoid-rich dark chocolate, coronary artery diameter was increased significantly (from 2.36+/-0.51 to 2.51+/-0.59 mm, P<0.01), whereas it remained unchanged after control chocolate. Endothelium-dependent coronary vasomotion improved significantly after dark chocolate (4.5+/-11.4% versus -4.3+/-11.7% in the placebo group, P=0.01). Platelet adhesion decreased from 4.9+/-1.1% to 3.8+/-0.8% (P=0.04) in the dark chocolate group but remained unchanged in the control group. Dark chocolate induces coronary vasodilation, improves coronary vascular function, and decreases platelet adhesion 2 hours after consumption. These immediate beneficial effects were paralleled by a significant reduction of serum oxidative stress and were positively correlated with changes in serum epicatechin concentration.

  7. Monorail Piccolino catheter: a new rapid exchange/ultralow profile coronary angioplasty system.

    PubMed

    Mooney, M R; Douglas, J S; Mooney, J F; Madison, J D; Brandenburg, R O; Fernald, R; Van Tassel, R A

    1990-06-01

    The Monorail Piccolino coronary angioplasty balloon catheter (MBC) was evaluated on 118 patients at two centers. Technical success was achieved in 110 patients (93%). Time for catheter exchange and total fluoroscopy time were significantly lower for the Monorail catheter than with standard equipment (exchange time 97 vs. 170 seconds P less than .05 and fluoroscopy time 17 vs. 88 seconds P less than .001). The advantages of rapid exchange and the ability of utilize 2 Monorail balloon catheters through one 9F guiding catheter for simultaneous inflations allowed for maximal flexibility in treating patients with bifurcation lesions. The double wire approach utilizing one Monorail balloon catheter with a 7F guiding catheter was also technically successful. The Monorail Piccolino balloon catheter has unique features that allow for greater ease of operator use, rapid catheter exchange, and optimal angiographic visualization. It is felt that this catheter design provides distinct advantages over standard angioplasty equipment.

  8. Beat-to-beat respiratory motion correction with near 100% efficiency: a quantitative assessment using high-resolution coronary artery imaging.

    PubMed

    Scott, Andrew D; Keegan, Jennifer; Firmin, David N

    2011-05-01

    This study quantitatively assesses the effectiveness of retrospective beat-to-beat respiratory motion correction (B2B-RMC) at near 100% efficiency using high-resolution coronary artery imaging. Three-dimensional (3D) spiral images were obtained in a coronary respiratory motion phantom with B2B-RMC and navigator gating. In vivo, targeted 3D coronary imaging was performed in 10 healthy subjects using B2B-RMC spiral and navigator gated balanced steady-state free-precession (nav-bSSFP) techniques. Vessel diameter and sharpness in proximal and mid arteries were used as a measure of respiratory motion compensation effectiveness and compared between techniques. Phantom acquisitions with B2B-RMC were sharper than those acquired with navigator gating (B2B-RMC vs. navigator gating: 1.01±0.02 mm(-1) vs. 0.86±0.08 mm(-1), P<.05). In vivo B2B-RMC respiratory efficiency was significantly and substantially higher (99.7%±0.5%) than nav-bSSFP (44.0%±8.9%, P<.0001). Proximal and mid vessel sharpnesses were similar (B2B-RMC vs. nav-bSSFP, proximal: 1.00±0.14 mm(-1) vs. 1.08±0.11 mm(-1), mid: 1.01±0.11 mm(-1) vs. 1.05±0.12 mm(-1); both P=not significant [ns]). Mid vessel diameters were not significantly different (2.85±0.39 mm vs. 2.80±0.35 mm, P=ns), but proximal B2B-RMC diameters were slightly higher (2.85±0.38 mm vs. 2.70±0.34 mm, P<.05), possibly due to contrast differences. The respiratory efficiency of B2B-RMC is less variable and significantly higher than navigator gating. Phantom and in vivo vessel sharpness and diameter values suggest that respiratory motion compensation is equally effective. Copyright © 2011 Elsevier Inc. All rights reserved.

  9. Beat-to-beat respiratory motion correction with near 100% efficiency: a quantitative assessment using high-resolution coronary artery imaging☆

    PubMed Central

    Scott, Andrew D.; Keegan, Jennifer; Firmin, David N.

    2011-01-01

    This study quantitatively assesses the effectiveness of retrospective beat-to-beat respiratory motion correction (B2B-RMC) at near 100% efficiency using high-resolution coronary artery imaging. Three-dimensional (3D) spiral images were obtained in a coronary respiratory motion phantom with B2B-RMC and navigator gating. In vivo, targeted 3D coronary imaging was performed in 10 healthy subjects using B2B-RMC spiral and navigator gated balanced steady-state free-precession (nav-bSSFP) techniques. Vessel diameter and sharpness in proximal and mid arteries were used as a measure of respiratory motion compensation effectiveness and compared between techniques. Phantom acquisitions with B2B-RMC were sharper than those acquired with navigator gating (B2B-RMC vs. navigator gating: 1.01±0.02 mm−1 vs. 0.86±0.08 mm−1, P<.05). In vivo B2B-RMC respiratory efficiency was significantly and substantially higher (99.7%±0.5%) than nav-bSSFP (44.0%±8.9%, P<.0001). Proximal and mid vessel sharpnesses were similar (B2B-RMC vs. nav-bSSFP, proximal: 1.00±0.14 mm−1 vs. 1.08±0.11 mm−1, mid: 1.01±0.11 mm−1 vs. 1.05±0.12 mm−1; both P=not significant [ns]). Mid vessel diameters were not significantly different (2.85±0.39 mm vs. 2.80±0.35 mm, P=ns), but proximal B2B-RMC diameters were slightly higher (2.85±0.38 mm vs. 2.70±0.34 mm, P<.05), possibly due to contrast differences. The respiratory efficiency of B2B-RMC is less variable and significantly higher than navigator gating. Phantom and in vivo vessel sharpness and diameter values suggest that respiratory motion compensation is equally effective. PMID:21292418

  10. Cryoplasty for femoropopliteal arterial disease: late angiographic results of initial human experience.

    PubMed

    Fava, Mario; Loyola, Soledad; Polydorou, Antonios; Papapavlou, Prodromos; Polydorou, Adamandia; Mendiz, Oscar; Joye, James D

    2004-11-01

    A new form of angioplasty, called cryoplasty, was developed to improve the late results typically associated with percutaneous transluminal angioplasty. Cryoplasty combines the dilation force of percutaneous transluminal angioplasty with the delivery of cold thermal energy to the vessel wall. This study reports the authors' early clinical experience with cryoplasty in patients with femoropopliteal disease. Fifteen patients with femoropopliteal arterial lesions were treated with cryoplasty (CryoVascular Systems, Los Gatos, CA). Cryoplasty was performed at 6 atm of pressure and delivered at -10 degrees C for 60 seconds. The ankle-brachial index (ABI) was measured at baseline, 24 hours after cryoplasty, and at 1 and 3 months during follow-up. Repeated angiography was performed at 6 and 18 months to determine short-term and late primary patency. Cryoplasty was technically successful in 93% of patients (< 30% residual stenosis and less then grade C dissection). ABIs at baseline were 0.64 +/- 0.08 and improved the day after cryoplasty to 0.95 +/- 0.09 (P < .05). ABIs were well maintained at 1 and 3 months with measurements of 0.94 +/- 0.09 and 0.92 +/- 0.10, respectively (P < .05 vs baseline). Baseline angiographic diameter stenosis improved significantly immediately following cryoplasty (86% +/- 12% to 16% +/- 3%; P < .05). Angiography at 6 months revealed 0% binary restenosis and insignificant change in residual stenosis from the acute cryoplasty results (16 +/- 3% vs 21 +/- 5%; P = NS). Late angiographic follow-up at 14 months +/- 4 demonstrated primary patency of 83.3%. Cryoplasty was able to achieve substantial dilation of femoropopliteal lesions with well-preserved late angiographic patency. Cryoplasty represents a potential advance in the field of endovascular medicine.

  11. Comparison of fluoro and cine coronary angiography: balancing acceptable outcomes with a reduction in radiation dose.

    PubMed

    Olcay, Ayhan; Guler, Ekrem; Karaca, Ibrahim Oguz; Omaygenc, Mehmet Onur; Kizilirmak, Filiz; Olgun, Erkam; Yenipinar, Esra; Cakmak, Huseyin Altug; Duman, Dursun

    2015-04-01

    Use of last fluoro hold (LFH) mode in fluoroscopy, which enables the last live image to be saved and displayed, could reduce radiation during percutaneous coronary intervention when compared with cine mode. No previous study compared coronary angiography radiation doses and image quality between LFH and conventional cine mode techniques. We compared cumulative dose-area product (DAP), cumulative air kerma, fluoroscopy time, contrast use, interobserver variability of visual assessment between LFH angiography, and conventional cine angiography techniques. Forty-six patients were prospectively enrolled into the LFH group and 82 patients into the cine angiography group according to operator decision. Mean cumulative DAP was higher in the cine group vs the LFH group (50058.98 ± 53542.71 mGy•cm² vs 11349.2 ± 8796.46 mGy•cm²; P<.001). Mean fluoroscopy times were higher in the cine group vs the LFH group (3.87 ± 5.08 minutes vs 1.66 ± 1.51 minutes; P<.01). Mean contrast use was higher in the cine group vs the LFH group (112.07 ± 43.79 cc vs 88.15 ± 23.84 cc; P<.001). Mean value of Crombach's alpha was not statistically different between visual estimates of three operators between cine and LFH angiography groups (0.66680 ± 0.19309 vs 0.54193 ± 0.31046; P=.20). Radiation doses, contrast use, and fluoroscopy times are lower in fluoroscopic LFH angiography vs cine angiography. Interclass variability of visual stenosis estimation between three operators was not different between cine and LFH groups. Fluoroscopic LFH images conventionally have inferior diagnostic quality when compared with cine coronary angiography, but with new angiographic systems with improved LFH image quality, these images may be adequate for diagnostic coronary angiography.

  12. Quantitative Assessment of Neovascularization after Indirect Bypass Surgery: Color-Coded Digital Subtraction Angiography in Pediatric Moyamoya Disease.

    PubMed

    Cho, H-H; Cheon, J-E; Kim, S-K; Choi, Y H; Kim, I-O; Kim, W S; Lee, S-M; You, S K; Shin, S-M

    2016-05-01

    For the postoperative follow-up in pediatric patients with Moyamoya disease, it is essential to evaluate the degree of neovascularization status. Our aim was to quantitatively assess the neovascularization status after bypass surgery in pediatric Moyamoya disease by using color-coded digital subtraction angiography. Time-attenuation intensity curves were generated at ROIs corresponding to surgical flap sites from color-coded DSA images of the common carotid artery, internal carotid artery, and external carotid artery angiograms obtained pre- and postoperatively in 32 children with Moyamoya disease. Time-to-peak and area under the curve values were obtained. Postoperative changes in adjusted time-to-peak (ΔTTP) and ratios of adjusted area under the curve changes (ΔAUC ratio) of common carotid artery, ICA, and external carotid artery angiograms were compared across clinical and angiographic outcome groups. To analyze diagnostic performance, we categorized clinical outcomes into favorable and unfavorable groups. The ΔTTP at the common carotid artery increased among clinical and angiographic outcomes, in that order, with significant differences (P = .003 and .005, respectively). The ΔAUC ratio at the common carotid artery and external carotid artery also increased, in that order, among clinical and angiographic outcomes with a significant difference (all, P = .000). The ΔAUC ratio of ICA showed no significant difference among clinical and angiographic outcomes (P = .418 and .424, respectively). The ΔTTP for the common carotid artery of >1.27 seconds and the ΔAUC ratio of >33.5% for the common carotid artery and 504% for the external carotid artery are revealed as optimal cutoff values between favorable and unfavorable groups. Postoperative changes in quantitative values obtained with color-coded DSA software showed a significant correlation with outcome scores and can be used as objective parameters for predicting the outcome in pediatric Moyamoya disease, with

  13. Clinical results of stereotactic heavy-charged-particle radiosurgery for intracranial angiographically occult vascular malformations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Levy, R.P.; Fabrikant, J.I.; Phillips, M.H.

    1989-12-01

    Angiographically occult vascular malformations (AOVMs) of the brain have been recognized for many years to cause neurologic morbidity and mortality. They generally become symptomatic due to intracranial hemorrhage, focal mass effect, seizures or headaches. The true incidence of AOVMs is unknown, but autopsy studies suggest that they are more common than high-flow angiographically demonstrable arteriovenous malformations (AVMs). We have developed stereotactic heavy-charged-particle Bragg peak radiosurgery for the treatment of inoperable intracranial vascular malformations, using the helium ion beams at the Lawrence Berkeley Laboratory 184-inch Synchrocyclotron and Bevatron. This report describes the protocol for patient selection, radiosurgical treatment planning method, clinicalmore » and neuroradiologic results and complications encountered, and discusses the strengths and limitations of the method. 10 refs., 1 fig.« less

  14. Use of antegrade dissection re-entry in coronary chronic total occlusion percutaneous coronary intervention in a contemporary multicenter registry.

    PubMed

    Danek, Barbara Anna; Karatasakis, Aris; Karmpaliotis, Dimitri; Alaswad, Khaldoon; Yeh, Robert W; Jaffer, Farouc A; Patel, Mitul; Bahadorani, John; Lombardi, William L; Wyman, Michael R; Grantham, J Aaron; Doing, Anthony; Moses, Jeffrey W; Kirtane, Ajay; Parikh, Manish; Ali, Ziad A; Kalra, Sanjog; Kandzari, David E; Lembo, Nicholas; Garcia, Santiago; Rangan, Bavana V; Thompson, Craig A; Banerjee, Subhash; Brilakis, Emmanouil S

    2016-07-01

    We assessed efficacy and safety of chronic total occlusion (CTO) percutaneous coronary intervention (PCI) using antegrade dissection re-entry (ADR). We examined outcomes of ADR among 1313 CTO PCIs performed at 11 US centers between 2012-2015. 84.1% of patients were men. Prevalence of prior coronary artery bypass graft surgery was 34.3%. Overall technical and procedural success were 90.1% and 88.7%, respectively. In-hospital major adverse cardiovascular events (MACE) occurred in 31 patients (2.4%). ADR was used in 458 cases (34.9%), and was the first strategy in 169 cases (12.9%). ADR cases were angiographically more complex than non-ADR cases (mean J-CTO score: 2.8±1.2 vs. 2.4±1.2, p<0.001). ADR was performed using the CrossBoss catheter in 246 of 458 (53.7%) and the Stingray system in 251 ADR cases (54.8%). Compared with non-ADR cases, ADR cases had lower technical (86.9% vs. 91.8%, p=0.005) and procedural success (85.0% vs. 90.7%, p=0.002), but similar risk for MACE (2.9% vs. 2.2%, p=0.42). ADR was associated with longer procedure and fluoroscopy time, and higher patient air kerma dose and contrast volume (all p<0.001). After excluding retrograde cases, ADR and antegrade wire escalation (AWE) had similar technical success (92.7% vs. 94.2%, p=0.43), procedural success (91.8% vs. 94.1%, p=0.23), and MACE (2.1% vs. 0.6%, p=0.12). ADR is used relatively frequently in contemporary CTO PCI, especially for challenging lesions and after failure of other strategies. ADR is associated with similar success rates and risk for complications as compared with AWE, and is important for achieving high procedural success. Published by Elsevier Ireland Ltd.

  15. Use of Antegrade Dissection Re-entry in Coronary Chronic Total Occlusion Percutaneous Coronary Intervention in a Contemporary Multicenter Registry

    PubMed Central

    Danek, Barbara Anna; Karatasakis, Aris; Karmpaliotis, Dimitri; Alaswad, Khaldoon; Yeh, Robert W.; Jaffer, Farouc A.; Patel, Mitul; Bahadorani, John; Lombardi, William L.; Wyman, Michael R.; Grantham, J. Aaron; Doing, Anthony; Moses, Jeffrey W.; Kirtane, Ajay; Parikh, Manish; Ali, Ziad; Kalra, Sanjog; Kandzari, David E.; Lembo, Nicholas; Garcia, Santiago; Rangan, Bavana V.; Thompson, Craig A.; Banerjee, Subhash; Brilakis, Emmanouil S.

    2016-01-01

    Background We assessed efficacy and safety of chronic total occlusion (CTO) percutaneous coronary intervention (PCI) using antegrade dissection re-entry (ADR). Methods We examined outcomes of ADR among 1,313 CTO PCIs performed at 11 US centers between 2012-2015. Results 84.1% of patients were men. Prevalence of prior coronary artery bypass graft surgery was 34.3%. Overall technical and procedural success were 90.1% and 88.7%, respectively. In-hospital major adverse cardiovascular events (MACE) occurred in 31 patients (2.4%). ADR was used in 458 cases (34.9%), and was the first strategy in 169 cases (12.9 %). ADR cases were angiographically more complex than non-ADR cases (mean J-CTO score: 2.8±1.2 vs. 2.4±1.2, p<0.001). ADR was performed using the CrossBoss catheter in 246 of 458 (53.7%) and the Stingray system in 251 ADR cases (54.8%). Compared with non-ADR cases, ADR cases had lower technical (86.9% vs. 91.8%, p=0.005) and procedural success (85.0% vs. 90.7%, p=0.002), but similar risk for MACE (2.9% vs. 2.2%, p=0.42). ADR was associated with longer procedure and fluoroscopy time, and higher patient air kerma dose and contrast volume (all p<0.001). After excluding retrograde cases, ADR and antegrade wire escalation (AWE) had similar technical success (92.7% vs. 94.2%, p=0.43) procedural success (91.8% vs. 94.1%, p=0.23), and MACE (2.1% vs. 0.6%, p=0.12). Conclusions ADR is used relatively frequently in contemporary CTO PCI, especially for challenging lesions and after failure of other strategies. ADR is associated with similar success rates and risk for complications as compared with AWE, and is important for achieving high procedural success. PMID:27088405

  16. Coronary Arteries

    MedlinePlus

    ... its own vascular system, called coronary circulation. The aorta (the main blood supplier to the body) branches ... blood to the rest of the body. Tags: aorta , arteries , blood , coronary arteries , coronary artery , coronary artery ...

  17. Periprocedural use of tirofiban in elective percutaneous coronary intervention for long coronary lesions in stable patients with overlapping drug-eluting stents--the PETITION study: a prospective, randomized, multicenter study.

    PubMed

    Zhang, Qi; Wang, Xiao Long; Liao, Min Lei; Hu, Jian; Yang, Zhen Kun; Ding, Feng Hua; Zhang, Jian Sheng; Du, Run; Zhu, Tian Qi; Shen, Wei Feng; Zhang, Rui Yan

    2015-03-01

    Patients are at risk of developing periprocedural myonecrosis after percutaneous coronary intervention (PCI). We investigated whether the use of the platelet glycoprotein (GP) IIb/IIIa receptor inhibitor tirofiban could reduce periprocedural myocardial infarction (PMI) in patients with stable coronary artery disease undergoing elective PCI with overlapping stent implantation for long lesions. A total of 748 stable angina patients with long lesions (≥ 40 mm in length) treated with overlapping stent implantation were randomly assigned to receive tirofiban (tirofiban group; n = 373) or conventional therapy (control group; n = 375). Intravenous tirofiban was initiated before PCI and maintained for 12 hr after the procedure. The primary endpoint was PMI, defined as an elevation in CK-MB > 3 times the upper limit of normal 12 hr after the index procedure. The secondary endpoint was major adverse cardiac events (MACE), including cardiac death, target vessel revascularization, and recurrent MI (re-MI), at one-year of clinical follow-up. The safety end-points included Thrombolysis in Myocardial Infarction (TIMI) major bleeding and stent thrombosis. Despite comparable angiographic and procedural characteristics, in the intention-to-treatment analysis, the primary endpoint was significantly reduced in the tirofiban group (4.0% vs. 11.5%, P < 0.001). Multivariate analysis revealed that the adjunctive use of tirofiban was the only negative predictor of PMI (OR 0.41, 95% CI 0.28-0.81, P < 0.01). At one-year of clinical follow-up, the overall occurrence of MACE was significantly lower in the tirofiban group (13.4% vs. 22.7%, P = 0.001). The rate of TIMI major bleeding and stent thrombosis did not differ significantly between the two groups. Our results show that the adjunctive use of tirofiban reduces the occurrence of PMI and MACE at one year in stable coronary artery disease patients undergoing elective PCI for long lesions with overlapping stent implantation. © 2015 Wiley

  18. Assessment of acute myocarditis by cardiac magnetic resonance imaging: Comparison of qualitative and quantitative analysis methods.

    PubMed

    Imbriaco, Massimo; Nappi, Carmela; Puglia, Marta; De Giorgi, Marco; Dell'Aversana, Serena; Cuocolo, Renato; Ponsiglione, Andrea; De Giorgi, Igino; Polito, Maria Vincenza; Klain, Michele; Piscione, Federico; Pace, Leonardo; Cuocolo, Alberto

    2017-10-26

    To compare cardiac magnetic resonance (CMR) qualitative and quantitative analysis methods for the noninvasive assessment of myocardial inflammation in patients with suspected acute myocarditis (AM). A total of 61 patients with suspected AM underwent coronary angiography and CMR. Qualitative analysis was performed applying Lake-Louise Criteria (LLC), followed by quantitative analysis based on the evaluation of edema ratio (ER) and global relative enhancement (RE). Diagnostic performance was assessed for each method by measuring the area under the curves (AUC) of the receiver operating characteristic analyses. The final diagnosis of AM was based on symptoms and signs suggestive of cardiac disease, evidence of myocardial injury as defined by electrocardiogram changes, elevated troponin I, exclusion of coronary artery disease by coronary angiography, and clinical and echocardiographic follow-up at 3 months after admission to the chest pain unit. In all patients, coronary angiography did not show significant coronary artery stenosis. Troponin I levels and creatine kinase were higher in patients with AM compared to those without (both P < .001). There were no significant differences among LLC, T2-weighted short inversion time inversion recovery (STIR) sequences, early (EGE), and late (LGE) gadolinium-enhancement sequences for diagnosis of AM. The AUC for qualitative (T2-weighted STIR 0.92, EGE 0.87 and LGE 0.88) and quantitative (ER 0.89 and global RE 0.80) analyses were also similar. Qualitative and quantitative CMR analysis methods show similar diagnostic accuracy for the diagnosis of AM. These findings suggest that a simplified approach using a shortened CMR protocol including only T2-weighted STIR sequences might be useful to rule out AM in patients with acute coronary syndrome and normal coronary angiography.

  19. Edge-to-Edge Technique to Minimize Ovelapping of Multiple Bioresorbable Scaffolds Plus Drug Eluting Stents in Revascularization of Long Diffuse Left Anterior Descending Coronary Artery Disease.

    PubMed

    Rigatelli, Gianluca; Avvocata, Fabio Dell'; Ronco, Federico; Giordan, Massimo; Roncon, Loris; Caprioglio, Francesco; Grassi, Giuseppe; Faggian, Giuseppe; Cardaioli, Paolo

    2016-06-01

    Implantation of Drug Eluting Stents (DES) plus bioresorbable scaffolds (BVS) in very long diffuse left anterior descending coronary artery (LAD) disease may be problematic because of multiple devices overlapping. We sought to assess the short and mid-tern outcomes of combined implantation of DES and BVS using a novel "edge-to-edge" technique in patients with diffuse LAD disease. Patients with long diffuse LAD disease were enrolled in a prospective registry from 1st August 2014 to 1st August 2015 and treated with IVUS-aided percutaneous coronary intervention using a DES plus a single or multiple BVS using a novel "edge-to-edge" technique. Clinical follow up and invasive follow up driven by clinical justification was performed. Twenty-three patients (5 females, mean age 59.1± 9.1 years) were enrolled. Mean length of LAD disease was 73.1 ± 20.6 mm. Mean number of DES and BVS implanted was 1.2 ± 0.4 and 1.7 ± 1.3, respectively. At a mean follow-up of 11.3 ± 3.8 months, no stent thrombosis or MACE were observed. Angiographic and IVUS follow-up at a mean of 6.6 ± 0.7 months showed no significant angiographic restenosis and no appreciable stent gaps. In revascularization of long diffuse disease of the LAD, the edge-to-edge implantation technique appears to be feasible resulting in no restenosis or thrombosis on the short-term follow-up. (J Interven Cardiol 2016;29:275-284). © 2016, Wiley Periodicals, Inc.

  20. Mini-STAR as bail-out strategy for percutaneous coronary intervention of chronic total occlusion.

    PubMed

    Galassi, Alfredo Ruggero; Tomasello, Salvatore Davide; Costanzo, Luca; Campisano, Maria Barbara; Barrano, Giombattista; Ueno, Masafumi; Tello-Montoliu, Antonio; Tamburino, Corrado

    2012-01-01

    Although the advancement of the equipment and the presence of innovative techniques, percutaneous coronary intervention (PCI) for chronic total occlusion (CTO) continues to be affected by lower procedural success in comparison with non occluded vessel PCI. We describe a new technique for the treatment of coronary CTO which utilizes a new generation of polymeric wires. From March 2009 to June 2010 different strategies were adopted as "bail out" after an initial attempt failed in 117 consecutive CTO lesions. Among these, conventional strategies (CS) such as parallel wire, sub-intimal tracking and re-entry (STAR), microchannel technique, intracoronary ultrasound guided revascularization and anchor balloon, were used in 75 cases (64.1%), while in the remaining a new technique, the "mini-STAR," was used (39.9%). Although no substantial differences were observed regarding the distribution of clinical features and angiographic lesions characteristics between the populations, mini-STAR was able to achieve a higher rate of procedural success in comparison with other CS (97.6% vs. 52%, P < 0.001) with lower contrast agent use (442 ± 259 cm(3) vs. 561 ± 243 cm(3), P = 0.01) and shorter procedural and fluoroscopy times (122 ± 61 vs. 157 ± 74 min, P = 0.009 and 60 ± 31 min vs. 75 ± 38 min, P = 0.03, respectively). No differences were observed in term of peri-procedural complications such as procedural myocardial infarction, coronary perforations, and contrast-induced nephropathy between mini-STAR and CS. The mini-STAR technique is a promising strategy for the treatment of CTO lesions, achieving a high procedural success rate and low occurrence of procedural adverse events. Copyright © 2011 Wiley Periodicals, Inc.

  1. Quantitative relationship between coronary artery calcium and myocardial blood flow by hybrid rubidium-82 PET/CT imaging in patients with suspected coronary artery disease.

    PubMed

    Assante, Roberta; Zampella, Emilia; Arumugam, Parthiban; Acampa, Wanda; Imbriaco, Massimo; Tout, Deborah; Petretta, Mario; Tonge, Christine; Cuocolo, Alberto

    2017-04-01

    We assessed the relationship between coronary artery calcium (CAC) score, myocardial blood flow (MBF) and coronary flow reserve (CFR) in patients undergoing hybrid 82 Rb positron emission tomography (PET)/computed tomography (CT) imaging for suspected CAD. We also evaluated if CAC score is able to predict a reduced CFR independently from conventional coronary risk factors. A total of 637 (mean age 58 ± 13 years) consecutive patients were studied. CAC score was measured according to the Agatston method and patients were categorized into 4 groups (0, 0.01-99.9, 100-399.9, and ≥400). Baseline and hyperemic MBF were automatically quantified. CFR was calculated as the ratio of hyperemic to baseline MBF and it was considered reduced when <2. Global CAC score showed a significant inverse correlation with hyperemic MBF and CFR (both P < .001), while no correlation between CAC score and baseline MBF was found. At multivariable logistic regression analysis age, diabetes and CAC score were independently associated with reduced CFR (all P < .001). The addition of CAC score to clinical data increased the global chi-square value for predicting reduced CFR from 81.01 to 91.13 (P < .01). Continuous net reclassification improvement, obtained by adding CAC score to clinical data, was 0.36. CAC score provides incremental information about coronary vascular function over established CAD risk factors in patients with suspected CAD and it might be helpful for identifying those with a reduced CFR.

  2. Angiographic Anatomy of External Iliac Arteries in the Sheep.

    PubMed

    Joscht, M; Martin, M; Henin, M; Nisolle, J F; Kirschvink, N; Dugdale, A; Godart, B; Coulon, H; Simon, V; Hontoir, F; Graffin, R; De Raeve, Y; Vandeweerd, J M

    2016-12-01

    External iliac artery atherosclerotic disease and aneurism occur in man. For treatment, imaging is required to facilitate minimally invasive introduction and advancement of stents within the intended vessels. Sheep are commonly used to test and improve stents. However, little information is published regarding the angiographic anatomy of the iliac arteries in the ovine species. The objective of this study was to describe the angiographic anatomy of the iliac arteries in the sheep. Computed tomography (CT) angiography and gross anatomical dissection were performed in, respectively, 10 and 43 adult ewes. Diameters and lengths of the arteries were measured. In comparison with man, salient anatomical differences were identified in the sheep: (1) the absence of common iliac arteries, (2) the common trunk at the origin of internal iliac arteries and (3) the location of the bifurcation of the external iliac arteries into femoral arteries in the pelvis (not in the limb). External iliac arteries in this series of sheep were 86 mm long in average and had a mean diameter of 7.5 mm. Lengths of arteries are only slightly different between man and sheep, while diameters are rather similar. Therefore, the sheep model appears to be sufficiently similar to man to test stent properties. This study provides useful reference images and measures of lengths and diameters of relevant arteries that could be applied to research with ovine models. © 2015 Blackwell Verlag GmbH.

  3. Direct stenting with a combined intravascular ultrasound-coronary stent delivery platform: a feasibility trial.

    PubMed

    Eeckhout, Eric; Berger, Alexandre; Roguelov, Christan; Lyon, Xavier; Imsand, Christophe; Fivaz-Arbane, Malika; Girod, Grégoire; De Benedetti, Edoardo

    2003-08-01

    IVUS is considered as the most accurate tool for the assessment of optimal stent deployment. Direct stenting has shown to be a safe, efficient, and resource-saving procedure in selected patients. In a prospective 1-month feasibility trial, a new combined IVUS-coronary stent delivery platform (Josonics Flex, Jomed, Helsingborn, Sweden) was evaluated during direct stenting in consecutive patients considered eligible for direct stenting. The feasibility endpoint was successful stent deployment without any clinical adverse event, while the efficacy endpoint was strategic adaptation according to standard IVUS criteria for optimal stent deployment at the intermediate phase (after a result considered angiographically optimal) and at the end of the intervention (after optimization according to IVUS standards). A total of 16 patients were successfully treated with this device without any major clinical complication. At the intermediate phase, optimal stent deployment was achieved in four patients only, while at the end only one patient had nonoptimal IVUS stent deployment. In particular, the minimal in-stent cross-section area increased from 6.3 +/- 1.2 to 8.3 +/- 2.5 mm(2). These preliminary data demonstrate the feasibility of direct stenting with a combined IVUS-stent catheter in selected patients and confirm the results from larger randomized trials on the impact of IVUS on strategic adaptations during coronary stent placement. Copyright 2003 Wiley-Liss, Inc.

  4. Anxiety, Depression, and General Psychological Distress in Patients with Coronary Slow Flow

    PubMed Central

    Karataş, Mehmet Baran; Şahan, Ebru; Özcan, Kazım Serhan; Çanga, Yiğit; Güngör, Barış; Onuk, Tolga; İpek, Göktürk; Çakıllı, Yasin; Arugaslan, Emre; Bolca, Osman

    2015-01-01

    Background The relationship between psychiatric illness and heart disease has been frequently discussed in the literature. The aim of the present study was to investigate the relationship between anxiety, depression and overall psychological distress, and coronary slow flow (CSF). Methods In total, 44 patients with CSF and a control group of 50 patients with normal coronary arteries (NCA) were prospectively recruited. Clinical data, admission laboratory parameters, and echocardiographic and angiographic characteristics were recorded. Symptom Checklist 90 Revised (SCL-90-R), Beck Depression Inventory (BDI), and Beck Anxiety Inventory (BAI) scales were administered to each patient. Results The groups were comparable with respect to age, sex, and atherosclerotic risk factors. In the CSF group, BAI score, BDI score, and general symptom index were significantly higher than controls (13 [18.7] vs. 7.5 [7], p = 0.01; 11 [14.7] vs. 6.5 [7], p = 0.01; 1.76 [0.81] vs. 1.1[0.24], p = 0.01; respectively). Patients with CSF in more than one vessel had the highest test scores. In univariate correlation analysis, mean thrombolysis in myocardial infarction (TIMI) frame counts were positively correlated with BAI (r = 0.56, p = 0.01), BDI (r = 0.47, p = 0.01), and general symptom index (r = 0.65, p = 0.01). The psychiatric tests were not correlated with risk factors for atherosclerosis. Conclusion Our study revealed higher rates of depression, anxiety, and overall psychological distress in patients with CSF. This conclusion warrants further studies. PMID:26559983

  5. Rate of change of left ventricular ejection fraction during exercise is superior to the peak ejection fraction for predicting functionally significant coronary artery disease.

    PubMed Central

    Sridhara, B S; Bhattacharya, S; Liu, X J; Broadhurst, P; Lahiri, A

    1993-01-01

    OBJECTIVE--To detect and characterise rapid temporal changes in the left ventricular response to exercise in patients with ischaemic heart disease and to relate these changes to the functional severity of coronary artery disease. BACKGROUND--The gamma camera does not allow the detection of rapid changes in cardiac function during exercise radionuclide ventriculography, the monitoring of which may improve the assessment of patients with ischaemic heart disease. METHODS--A miniature nuclear probe (Cardioscint) was used to monitor continuously left ventricular function during exercise in 31 patients who had coronary angiography for suspected coronary artery disease. A coronary angiographic jeopardy score was calculated for each patient. RESULTS--The coronary jeopardy score ranged from 0 to 12 (median 4). Ejection fraction fell significantly during exercise from 46% to 34%. Patients were divided into two groups based on the response of their ejection fraction to exercise. In 14 patients (group I), the peak change in ejection fraction coincided with the end of exercise, whereas in the other 17 patients (group II) the peak change in ejection fraction occurred before the end of exercise, resulting in a brief plateau. The peak change in ejection fraction and the time to its occurrence were independent predictors of coronary jeopardy (r = -0.59, p < 0.001 for peak change and r = -0.69, p < 0.001 for time to that change). The rate of change in ejection fraction was the strongest predictor of coronary jeopardy (r = -0.81, p < 0.001). In group I the peak change in ejection fraction was a poor predictor severity of coronary disease (r = -0.28, NS), whereas the time to peak and the rate of change in ejection fraction were good predictors (r = -0.65 and r = -0.73, p < 0.01). In group II the peak, the time to the peak, and the rate of change in ejection fraction were good predictors of coronary jeopardy (r = -0.75, r = -0.61, and r = -0.83, p < 0.01). CONCLUSION--The rate of

  6. Impact of an endothelial progenitor cell capturing stent on coronary microvascular function: comparison with drug-eluting stents.

    PubMed

    Choi, Woong Gil; Kim, Soo Hyun; Yoon, Hyung Seok; Lee, Eun Joo; Kim, Dong Woon

    2015-01-01

    Although drug-eluting stents (DESs) effectively reduce restenosis following percutaneous coronary intervention (PCI), they also delay re-endothelialization and impair microvascular function, resulting in adverse clinical outcomes. Endothelial progenitor cell (EPC) capturing stents, by providing a functional endothelial layer on the stent, have beneficial effects on microvascular function. However, data on coronary microvascular function in patients with EPC stents versus DESs are lacking. Seventy-four patients who previously underwent PCI were enrolled in this study. Microvascular function was evaluated 6 months after PCI based on the index of microvascular resistance (IMR) and the coronary flow reserve (CFR). IMR was calculated as the ratio of the mean distal coronary pressure at maximal hyperemia to the inverse of the hyperemic mean transit time (hTmn). The CFR was calculated by dividing the hTmn by the baseline mean transit time. Twenty-one patients (age, 67.2 ± 9.6 years; male:female, 15:6) with an EPC stent and 53 patients (age, 61.5 ± 14.7 years; male:female, 40:13) with second-generation DESs were included in the study. There were no significant differences in the baseline clinical and angiographic characteristics of the two groups. Angiography performed 6 months postoperatively did not show significant differences in their CFR values. However, patients with the EPC stent had a significantly lower IMR than patients with second-generation DESs (median, 25.5 [interquartile range, 12.85 to 28.18] vs. 29.0 [interquartile range, 15.42 to 39.23]; p = 0.043). Microvascular dysfunction was significantly improved after 6 months in patients with EPC stents compared to those with DESs. The complete re-endothelialization achieved with the EPC stent may provide clinical benefits over DESs, especially in patients with microvascular dysfunction.

  7. Comparison of in-hospital and follow-up results of directional atherectomy and stenting for ostial lesions of the left anterior descending coronary artery.

    PubMed

    Gambhir, D S; Batra, R; Singh, S; Sudha, R; Trehen, V; Arora, R

    1998-01-01

    Lesions at the ostium of the left anterior descending coronary artery constitute a distinct group because of suboptimal results and higher restenosis rate after balloon angioplasty. Several non-balloon devices have been used to improve the outcome of dilatation of such lesions. We retrospectively compared the in-hospital and follow-up results of directional coronary artherectomy and stents for the treatment of ostial lesions of the left anterior descending artery. Out of 37 patients, 12 underwent directional coronary atherectomy and 25, stent implantation. The two strategies were deployed at different periods over the past five years. The baseline clinical and angiographic characteristics were comparable in the two groups. Directional coronary atherectomy was done using 7Fr atherocath with adjunctive balloon angioplasty in all. All the stents were deployed using moderate to high pressure balloon inflation after adequate predilatation. While the pre-procedure luminal diameter stenosis was similar in the two groups (87.3 +/- 8.8% vs 89.3 +/- 7.2%; p = NS), the residual stenosis was significantly lower in the stent group (5 +/- 2.8%) compared to directional coronary atherectomy (18.7 +/- 9.8; p = 0.02). There was no significant difference in the primary success rate between the two devices (91.6% directional coronary atherectomy vs 100% stent; p = NS). One patient in the directional coronary atherectomy group developed acute closure followed by emergency coronary artery bypass graft surgery and death. No major complication was observed in the stent group. Over a mean follow-up of 9.9 +/- 11.6 months following directional coronary atherectomy and 8.6 +/- 4.4 months after stenting, significantly higher number of patients (60%) developed recurrence of angina or any event following directional coronary atherectomy compared to stent (15.8%; p < 0.02). There was no myocardial infarction, coronary artery bypass graft surgery or death in either group on follow-up. The need

  8. Diet and the role of lipoproteins, lipases, and thyroid hormones in coronary lesion growth

    NASA Technical Reports Server (NTRS)

    Barth, Jacques D.; Jansen, Hans; Reiber, Johan H. C.; Birkenhager, Jan C.; Kromhout, Daan

    1987-01-01

    The relationships between the coronary lesion growth and the blood contents of lipoprotein fractions, thyroic hormones, and the lipoprotein lipase activity were investigated in male patients with severe coronary atherosclerosis, who participated in a lipid-lowering dietary intervention program. A quantitative computer-assisted image-processing technique was used to assess the severity of coronary obstructions at the beginning of the program and at its termination two years later. Based on absolute coronary scores, patients were divided into a no-lesion growth group (14 patients) and a progression group (21 paients). At the end of the trial, the very-low-density lipoprotein cholesterol and triglycerides were found to be significantly higher, while the high-density lipoprotein cholesterol and hepatic lipase (HL) were lower in the progression group. Multivariate regression analysis showed HL to be the most important determinant of changes in coronary atherosclerotic lesions.

  9. Coronary artery size and disease in UK South Asian and Caucasian men.

    PubMed

    Zindrou, Dlear; Taylor, Kenneth M; Bagger, Jens Peder

    2006-04-01

    South Asian patients in the UK have a higher mortality rate after coronary artery bypass grafting (CABG) than Caucasian patients. As coronary artery size has been shown to correlate to outcome from bypass grafting, it has been suggested that smaller coronary arteries in South Asians as compared to Caucasians could contribute to a poorer outcome in the Asian population. We aimed to measure coronary artery size and disease in matched South Asian and Caucasian men undergoing first time coronary artery bypass grafting. Coronary arteriograms from 53 matched first generation South Asian and Caucasian men were examined. The patients had no history of myocardial infarction, coronary revascularisation, familial dyslipidaemia, diabetes or renal disease. They were individually matched for age, height, weight, body mass index and body surface area. Thereafter, coronary artery diameters and significant (> or =50%) diameter stenoses were measured in a blinded fashion using quantitative coronary angiography (QCA). In South Asian men, diameters of the left main stem (LMS) and the proximal left anterior descending, the circumflex and the right coronary arteries were 4.6+/-0.9 mm, 3.5+/-0.8 mm, 3.4+/-0.8 mm and 3.5+/-0.8 mm, respectively. The corresponding arterial diameters among Caucasian men (4.5+/-0.9 mm, 3.5+/-0.7 mm, 3.5+/-0.8 mm and 3.8+/-0.8 mm) did not differ from those in South Asians. There was no difference in the number of significant coronary artery stenoses between the two groups and no difference in bypass and cross-clamp times or in adverse outcome (one from each group died after coronary artery bypass grafting). Proximal coronary artery size and number of significant coronary stenoses did not differ between matched pairs of South Asian and Caucasian men using strict inclusion/exclusion criteria.

  10. Coronary microvascular dysfunction equivalent to left main coronary artery disease.

    PubMed

    Panç, Cafer; Kocaağa, Mehmet; Erdoğan, Onur; Sarıkaya, Remzi; Umman, Sabahattin

    2017-04-01

    Coronary microvascular dysfunction, also known as cardiac syndrome X, is a clinical syndrome presenting with typical angina and evidence of myocardial ischemia in the absence of flow-limiting stenosis on coronary angiography. Of patients undergoing coronary angiography due to suspected myocardial ischemia, 50% are found to have normal or near-normal coronary arteries. Described in this case report is a patient who developed hypotension and ST segment depressions during treadmill exercise test. Left main coronary artery or multivessel disease was suspected. Coronary angiography was normal, but coronary flow reserve measurement revealed severe microvascular dysfunction.

  11. Quantitative Measurement of Dissection Resistance in Intimal and Medial Layers of Human Coronary Arteries

    PubMed Central

    Wang, Ying; Johnson, John A.; Spinale, Francis G.; Sutton, Michael A.; Lessner, Susan M.

    2014-01-01

    The left anterior descending (LAD) coronary artery is the most frequently involved vessel in coronary artery dissection, a cause of acute coronary syndrome or sudden cardiac death. The biomechanical mechanisms underlying arterial dissection are not well understood. This study investigated the dissection properties of LAD specimens harvested from explanted hearts at the time of cardiac transplantation, from patients with primary dilated cardiomyopathy (n=12). Using a previously validated approach uniquely modified for these human LAD specimens, we quantified the local energy release rate, G, within different arterial layers during experimental dissection events (tissue tearing). Results show that the mean values of G during arterial dissection within the intima and within the media in human LADs are 20.7±16.5 J/m2 and 10.3±5.0 J/m2, respectively. The difference in dissection resistance between tearing events occurring within the intima and within the media is statistically significant. Our data fall in the same order of magnitude as most previous measurements of adhesive strength in other human arteries, with the differences in measured values of G within the layers most likely due to histologically observed differences in the structure and composition of arterial layers. PMID:24729631

  12. Long-term angiographic outcome of stent-assisted coiling compared to non-assisted coiling of intracranial saccular aneurysms

    PubMed Central

    Ozretić, David; Radoš, Marko; Pavliša, Goran; Poljaković, Zdravka

    2015-01-01

    Aim To compare angiographic result at long-term follow-up, and rates of progressive occlusion, recurrence, and retreatment of stent-assisted coiled (SAC) and non-assisted coiled (NAC) intracranial saccular aneurysms. Methods Retrospective evaluation of department records identified 260 patients with 283 saccular intracranial aneurysms who had long-term angiographic follow-up (more than 12 months) and were successfully treated with SAC (89 aneurysms) or NAC (194 aneurysms) at the University Hospital Center Zagreb from June 2005 to July 2012. Initial and control angiographic results in both groups were graded using Roy/Raymond scale, converted to descriptive terms, and the differences between them were evaluated for statistical significance. A multivariate analysis was performed to identify factors related to progression of aneurysm occlusion and recurrence at follow-up, and those related to aneurysm retreatment. Results There were more progressively occluded aneurysms in SAC group (38 of 89 aneurysms, 42.7%) than in NAC group (46 of 194, 23.7%) (P = 0.002), but there were no significant differences in the rates of recanalization, regrowth, and stable result. Multivariate logistic regression identified the use of stent as the most important factor associated with progressive occlusion (P = 0.015, odds ratio 2.22, 95% confidence interval 1.17-4.21), and large aneurysm size and posterior circulation location as most predictive of aneurysm recurrence and retreatment. Conclusion The use of stent is associated with delayed occlusion of initially incompletely coiled aneurysms during follow-up, but does not reduce the rate of recurrence and retreatment compared to coiling alone. Long-term angiographic follow-up is needed for both SAC and NAC aneurysms. PMID:25727039

  13. Angiographic evaluation of the effect of intra-arterial milrinone therapy in patients with vasospasm from aneurysmal subarachnoid hemorrhage.

    PubMed

    Shankar, Jai Jai Shiva; dos Santos, Marlise P; Deus-Silva, Leonardo; Lum, Cheemun

    2011-02-01

    Several methods have been used to treat cerebral vasospasm, which is a major cause of morbidity and mortality in patients with aneurysmal subarachnoid hemorrhage (SAH). Here, we examined the effectiveness and safety of intra-arterial injection of milrinone for the treatment of vasospasm. Consecutive patients with angiographically confirmed vasospasm received intra-arterial milrinone between January 2006 and December 2007. The improvement in diameter of vessel (in millimeters) following treatment was assessed by paired t test for statistical significance. The angiographic improvement of supraclinoid internal carotid artery, M1 segment of middle cerebral artery, and A1 and A2 segment of anterior cerebral artery was compared with the modified Rankin score of the patients at discharge. A total of 15 milrinone treatments were performed in 14 patients (11 females and 3 males) with mean age of 52.7 years (31-68 years). There was significant angiographic improvement after milrinone therapy (p < 0.0001). Intra-arterial milrinone was a safe and effective treatment of cerebral vasospasm following aneurysmal SAH.

  14. A prospective, multicenter, post marketing surveillance study to evaluate the safety and effectiveness of the Superia-Sirolimus Eluting Coronary Stent System (SSECSS) implanted during routine clinical practice in India.

    PubMed

    Chandra, Praveen; Kumar, Tarun

    2014-01-01

    A prospective, multicenter, post marketing surveillance study to evaluate the safety and effectiveness of the Superia-Sirolimus Eluting Coronary Stent System (SSECSS) implanted during routine clinical practice in India. 1. To study the MACE and in stent and In-segment Loss at Six Months (in a pre selected group of 50 patients). 1. Clinical and procedural success. This is a prospective, open label, single-arm, multicenter (16 sites), post marketing observational study enrolling patients implanted with Superia-Sirolimus Eluting Coronary Stent (SSECS) in routine clinical practice in India. A total of 200 Patients of coronary Artery Disease (CAD) implanted with Superia-Sirolimus Eluting Coronary Stent (SSECS) were enrolled. Clinical assessments were done at 30 days, 180 days and at 1, 2 years either telephonically or office visit. A cohort of 50 pre-selected patients were followed up for angiographic evaluation at 180 days. MACE at 12 month of follow up was 1.71%.Late lumen loss, in segment was 0.14 and in stent was 0.10 mm at 6 month of follow-up. TLR was required only in 2 patients. Superia stent is as safe as other biodegradable polymer stent in the market and time has come for biodegradable polymer stent with thin struts. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  15. Peripheral blood gene expression profile of atherosclerotic coronary artery disease in patients of different ethnicity in Malaysia.

    PubMed

    Abdullah, Mohd Hafiz Ngoo; Othman, Zulhabri; Noor, Hamdan Mohd; Arshad, Siti Suri; Yusof, Ahmad Khairuddin Mohd; Jamal, Rahman; Rahman, Abdul Rashid Abdul

    2012-09-01

    The molecular basis of coronary artery disease (CAD) has been widely studied in the western world but there is no published work on the Malaysian population. This study looked at the global gene expression profiling of the peripheral blood of patients with CAD from the 3 main ethnic groups in Malaysia. Male subjects selected were based on angiographically confirmed CAD (≥50% stenosis) and normal control subjects (0% stenosis) with age range of 55.6±5.3 and 51.0±5.5 years, respectively. The global gene expression of 12 angiographically documented CAD patients and 11 matched control subjects were performed. The combined group samples identified 6 up regulated differential expression (DE) genes (GHRL, LTA, CBS, HP, ITGA2B, and OLR1) and 12 down regulated DE genes (IL18R1, ITGA2B, IL18RAP, HP, OLR1, SOD2 ITGB3, IL1B, MMP9, PLA2G7, UTS2, and CBS) to be involved in CAD at the fold change of 1.3 with fault discovery rate (FDR) of 1%. Three genes, MMP9, IL1B, and SOD2 were down regulated in all the 3 ethnic groups making them potential biomarker candidates for CAD across all three ethnicities. Further verification in a cohort study is needed. Copyright © 2012 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  16. Characteristics and outcomes in patients undergoing percutaneous coronary intervention following cardiac arrest (from the NCDR).

    PubMed

    Gupta, Navdeep; Kontos, Michael C; Gupta, Aditi; Dai, David; Vetrovec, George W; Roe, Matthew T; Messenger, John

    2014-04-01

    Outcomes in patients with out-of-hospital cardiac arrest (CA) who undergo percutaneous coronary intervention (PCI) have been limited to small, mostly single-center studies. We compared patients who underwent PCI after CA included in the CathPCI Registry with those without CA. Patients with ST elevation were classified as ST-elevation myocardial infarction (STEMI); all other patients having PCI were classified as without STEMI. Patients with CA in each group were compared with the corresponding non-CA groups for baseline characteristics, angiographic findings, and outcomes. A total of 594,734 patients underwent PCI, of whom 114,768 had STEMI, including 9,375 (8.2%) had CA, and 479,966 had without STEMI, including 2,775 (0.6%) had CA. Patients with CA were similar in age to patients with non-CA, with a lower frequency of coronary disease risk factors and known coronary disease. On angiography, patients with CA were significantly more likely to have more complex lesions with worse baseline thrombolysis in myocardial infarction flow. Patients with CA were significantly more likely to have cardiogenic shock, both for patients with STEMI (51% vs 7.2%, respectively) and for patients without STEMI (38% vs 0.8%, respectively, both p<0.001). In-hospital mortality was substantially worse in patients with CA, for both patients with STEMI (24.9% vs 3.1%, respectively) and patients without STEMI (18.7% vs 0.4%, respectively). In conclusion, patients who underwent PCI after CA had more complex anatomy, more shock, and higher mortality. The substantially increased mortality in patients with CA has important implications for the development and regionalization of centers for CA. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. SPECT myocardial perfusion imaging as an adjunct to coronary calcium score for the detection of hemodynamically significant coronary artery stenosis

    PubMed Central

    2012-01-01

    Background Coronary artery calcifications (CAC) are markers of coronary atherosclerosis, but do not correlate well with stenosis severity. This study intended to evaluate clinical situations where a combined approach of coronary calcium scoring (CS) and nuclear stress test (SPECT-MPI) is useful for the detection of relevant CAD. Methods Patients with clinical indication for invasive coronary angiography (ICA) were included into our study during 08/2005-09/2008. At first all patients underwent CS procedure as part of the study protocol performed by either using a multidetector computed tomography (CT) scanner or a dual-source CT imager. CAC were automatically defined by dedicated software and the Agatston score was semi-automatically calculated. A stress-rest SPECT-MPI study was performed afterwards and scintigraphic images were evaluated quantitatively. Then all patients underwent ICA. Thereby significant CAD was defined as luminal stenosis ≥75% in quantitative coronary analysis (QCA) in ≥1 epicardial vessel. To compare data lacking Gaussian distribution an unpaired Wilcoxon-Test (Mann–Whitney) was used. Otherwise a Students t-test for unpaired samples was applied. Calculations were considered to be significant at a p-value of <0.05. Results We consecutively included 351 symptomatic patients (mean age: 61.2±12.3 years; range: 18–94 years; male: n=240) with a mean Agatston score of 258.5±512.2 (range: 0–4214). ICA verified exclusion of significant CAD in 66/67 (98.5%) patients without CAC. CAC was detected in remaining 284 patients. In 132/284 patients (46.5%) with CS>0 significant CAD was confirmed by ICA, and excluded in 152/284 (53.5%) patients. Sensitivity for CAD detection by CS alone was calculated as 99.2%, specificity was 30.3%, and negative predictive value was 98.5%. An additional SPECT in patients with CS>0 increased specificity to 80.9% while reducing sensitivity to 87.9%. Diagnostic accuracy was 84.2%. Conclusions In patients without CS=0

  18. Standardized evaluation framework for evaluating coronary artery stenosis detection, stenosis quantification and lumen segmentation algorithms in computed tomography angiography.

    PubMed

    Kirişli, H A; Schaap, M; Metz, C T; Dharampal, A S; Meijboom, W B; Papadopoulou, S L; Dedic, A; Nieman, K; de Graaf, M A; Meijs, M F L; Cramer, M J; Broersen, A; Cetin, S; Eslami, A; Flórez-Valencia, L; Lor, K L; Matuszewski, B; Melki, I; Mohr, B; Oksüz, I; Shahzad, R; Wang, C; Kitslaar, P H; Unal, G; Katouzian, A; Örkisz, M; Chen, C M; Precioso, F; Najman, L; Masood, S; Ünay, D; van Vliet, L; Moreno, R; Goldenberg, R; Vuçini, E; Krestin, G P; Niessen, W J; van Walsum, T

    2013-12-01

    Though conventional coronary angiography (CCA) has been the standard of reference for diagnosing coronary artery disease in the past decades, computed tomography angiography (CTA) has rapidly emerged, and is nowadays widely used in clinical practice. Here, we introduce a standardized evaluation framework to reliably evaluate and compare the performance of the algorithms devised to detect and quantify the coronary artery stenoses, and to segment the coronary artery lumen in CTA data. The objective of this evaluation framework is to demonstrate the feasibility of dedicated algorithms to: (1) (semi-)automatically detect and quantify stenosis on CTA, in comparison with quantitative coronary angiography (QCA) and CTA consensus reading, and (2) (semi-)automatically segment the coronary lumen on CTA, in comparison with expert's manual annotation. A database consisting of 48 multicenter multivendor cardiac CTA datasets with corresponding reference standards are described and made available. The algorithms from 11 research groups were quantitatively evaluated and compared. The results show that (1) some of the current stenosis detection/quantification algorithms may be used for triage or as a second-reader in clinical practice, and that (2) automatic lumen segmentation is possible with a precision similar to that obtained by experts. The framework is open for new submissions through the website, at http://coronary.bigr.nl/stenoses/. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. The carina angle-new geometrical parameter associated with periprocedural side branch compromise and the long-term results in coronary bifurcation lesions with main vessel stenting only.

    PubMed

    Gil, Robert J; Vassilev, Dobrin; Formuszewicz, Radoslaw; Rusicka-Piekarz, Teresa; Doganov, Alexander

    2009-12-01

    The two main problems unresolved in coronary bifurcation stenting are periprocedural side branch compromise and higher restenosis at long term. The purpose of this study is to reveal the link between periprocedural side branch compromise and long-term results after main vessel stenting only in coronary bifurcations. Eighty-four patients formed the study population. The inclusion criteria were good-quality angiograms, with maximal between-branch angle opening, no overlap, permitting accurate angiographic analysis. Carina angle (alpha)-the distal angle between main vessel (MV) before bifurcation and side branch (SB)-was measured pre- and poststenting. Clinical follow-up 9-12 months was obtained with coronary angiography if needed. The patient population was high-risk with 33% diabetics and 84% two- and three-vessel disease. Ninety-five stents were implanted in 92 lesions, with three T-stenting cases. Drug-eluting stents were implanted in 54%. Kissing-balloon (KBI) or sequential inflation was performed in 35%. SB functional closure occurred in 17.4%, with independent predictors alpha < 40 degrees and diameter ratio MB/SB >1.22. After 12+/-4 months there were five myocardial infarctions (6%) and 13 (15%) target lesion revascularization procedures. Independent predictors of major cardiovascular events were carina angle <40 degrees , MB lesion length >8 mm, negative change of between-branch angle, DES usage, and KBI. Smaller carina angle with straightening of MV-main branch from stent implantation in coronary bifurcations predicted higher SB compromise, restenosis, and MACE rates during follow-up of 1 year.

  20. Quantitative troponin and death, cardiogenic shock, cardiac arrest and new heart failure in patients with non-ST-segment elevation acute coronary syndromes (NSTE ACS): insights from the Global Registry of Acute Coronary Events.

    PubMed

    Jolly, Sanjit S; Shenkman, Heather; Brieger, David; Fox, Keith A; Yan, Andrew T; Eagle, Kim A; Steg, P Gabriel; Lim, Ki-Dong; Quill, Ann; Goodman, Shaun G

    2011-02-01

    The objective of this study was to determine if the extent of quantitative troponin elevation predicted mortality as well as in-hospital complications of cardiac arrest, new heart failure and cardiogenic shock. 16,318 patients with non-ST-segment elevation acute coronary syndromes (NSTE ACS) from the Global Registry of Acute Coronary Events (GRACE) were included. The maximum 24 h troponin value as a multiple of the local laboratory upper limit of normal was used. The population was divided into five groups based on the degree of troponin elevation, and outcomes were compared. An adjusted analysis was performed using quantitative troponin as a continuous variable with adjustment for known prognostic variables. For each approximate 10-fold increase in the troponin ratio, there was an associated increase in cardiac arrest, sustained ventricular tachycardia (VT) or ventricular fibrillation (VF) (1.0, 2.4, 3.4, 5.9 and 13.4%; p<0.001 for linear trend), cardiogenic shock (0.5, 1.4, 2.0, 4.4 and 12.7%; p<0.001), new heart failure (2.5, 5.1, 7.4, 11.6 and 15.8%; p<0.001) and mortality (0.8, 2.2, 3.0, 5.3 and 14.0%; p<0.001). These findings were replicated using the troponin ratio as a continuous variable and adjusting for covariates (cardiac arrest, sustained VT or VF, OR 1.56, 95% CI 1.39 to 1.74; cardiogenic shock, OR 1.87, 95% CI 1.61 to 2.18; and new heart failure, OR 1.57, 95% CI 1.45 to 1.71). The degree of troponin elevation was predictive of early mortality (HR 1.61, 95% CI 1.44 to 1.81; p<0.001 for days 0-14) and longer term mortality (HR 1.18, 95% CI 1.07 to 1.30, p=0.001 for days 15-180). The extent of troponin elevation is an independent predictor of morbidity and mortality.

  1. Coronary angiography

    MedlinePlus

    ... Angiogram - coronary; Coronary artery disease - angiography; CAD - angiography; Angina - angiography; Heart disease - angiography ... Coronary angiography may be done if: You have angina for the first time. Your angina that is ...

  2. Evaluation of Tp-Te Interval and Tp-Te/QT Ratio in Patients with Coronary Slow Flow Tp-Te/QT Ratio and Coronary Slow Flow.

    PubMed

    Tenekecioglu, Erhan; Karaagac, Kemal; Yontar, Osman Can; Agca, Fahriye Vatansever; Ozluk, Ozlem Arican; Tutuncu, Ahmet; Arslan, Burhan; Yilmaz, Mustafa

    2015-06-01

    Coronary slow flow (CSF) phenomenon is described by angiographically normal coronary arteries with delayed opacification of the distal vasculature. Several studies have suggested that the interval from the peak to the end of the electrocardiographic T wave (Tp-Te) may correspond to the transmural dispersion of the repolarization and that increased Tp-Te interval and Tp-Te/QT ratio are associated with malignant ventricular arrhythmias. The aim of this study was to evaluate the ventricular repolarization by using Tp-Te interval and Tp-Te/QT ratio in patients with CSF. This study included 50 CSF patients (40 male, mean age 48.6±12.5 years) and 40 control individuals (23 male, mean age 47.8±12.5 years). Tp-Te interval and Tp-Te/QT ratio were measured from the 12-lead electrocardiogram. These parameters were compared in groups. Baseline characteristics of the study groups were comparable. In electrocardiographic parameters analysis, QT and corrected QT were similar in CSF patients compared to the controls (357±35.2 vs 362±38.0 milliseconds and 419±25.8 vs 430±44.2 milliseconds, all p value >0.05). Tp-Te interval, Tp-Te/QT and Tp-Te/QTc ratio were significantly higher in CSF patients (85±13.7 vs 74±9.9 milliseconds and 0.24±0.03 vs 0.20±0.02 and 0.20±0.03 vs 0.17±0.02 all p value <0.001). Our study revealed that QTd, Tp-Te interval and Tp-Te/QT ratio are prolonged in patients with CSF.

  3. Early outcomes of on-pump versus off-pump coronary artery bypass grafting.

    PubMed

    Hussain, Ghulam; Azam, Hammad; Baig, Mirza Ahmad Raza; Ahmad, Naseem

    2016-01-01

    To see the early post-operative outcomes of off-pump versus on-pump coronary artery bypass graft surgery. This retrospective analytical study was conducted at Ch. Pervaiz Elahi Institute of Cardiology Multan, Pakistan. Our Primary outcome variables were; necessity of inotropic support, nonfatal myocardial infarction, ICU stay, nonfatal stroke, new renal failure requiring dialysis and death within 30 days after operation. There were two groups of patients; Group-I (On-pump group) and Group-II (Off-pump Group). SPSS V17 was used for data analysis. Independent sample t-test and Mann Whitney U test were used to compare quantitative Variables. Chi-square test and Fisher's exact test were used to analyze qualitative variables. P-value ≤ 0.05 was considered significant. Three hundred patients were included in this study. There were no significant difference regarding risk factors except hyper-cholestrolemia which was high in off pump group (p-value 0.05). Angiographic and Echocardiographic characteristics e.g. preoperative ejection fraction, LV function grade and severity of CAD was same between the groups. Mortality risk scores and Priority status for surgery were also same. Regarding post-operative outcomes; Post-op CKMB Levels, need and duration of inotropic support, mechanical ventilation time and ICU stay was significantly less in Off-Pump group (p-value 0.001, <0.0001, 0.006, 0.025 and 0.001 resp.). Peri-operative chest drainage was significantly high in On-pump CABG group (p-value 0.027). Incidence of post-op complications was not statistically different between the groups. At 30 days follow-up, Incidence of myocardial infarction, necessity and duration of inotropic support, ICU stay period and peri-operative bleeding were significantly less in off-pump group. The incidence of neurologic, pulmonary and renal complications was same between the off-pump and on-pump groups.

  4. Early outcomes of on-pump versus off-pump coronary artery bypass grafting

    PubMed Central

    Hussain, Ghulam; Azam, Hammad; Baig, Mirza Ahmad Raza; Ahmad, Naseem

    2016-01-01

    Objectives: To see the early post-operative outcomes of off-pump versus on-pump coronary artery bypass graft surgery. Methods: This retrospective analytical study was conducted at Ch. Pervaiz Elahi Institute of Cardiology Multan, Pakistan. Our Primary outcome variables were; necessity of inotropic support, nonfatal myocardial infarction, ICU stay, nonfatal stroke, new renal failure requiring dialysis and death within 30 days after operation. There were two groups of patients; Group-I (On-pump group) and Group-II (Off-pump Group). SPSS V17 was used for data analysis. Independent sample t-test and Mann Whitney U test were used to compare quantitative Variables. Chi-square test and Fisher’s exact test were used to analyze qualitative variables. P-value ≤ 0.05 was considered significant. Results: Three hundred patients were included in this study. There were no significant difference regarding risk factors except hyper-cholestrolemia which was high in off pump group (p-value 0.05). Angiographic and Echocardiographic characteristics e.g. preoperative ejection fraction, LV function grade and severity of CAD was same between the groups. Mortality risk scores and Priority status for surgery were also same. Regarding post-operative outcomes; Post-op CKMB Levels, need and duration of inotropic support, mechanical ventilation time and ICU stay was significantly less in Off-Pump group (p-value 0.001, <0.0001, 0.006, 0.025 and 0.001 resp.). Peri-operative chest drainage was significantly high in On-pump CABG group (p-value 0.027). Incidence of post-op complications was not statistically different between the groups. Conclusions: At 30 days follow-up, Incidence of myocardial infarction, necessity and duration of inotropic support, ICU stay period and peri-operative bleeding were significantly less in off-pump group. The incidence of neurologic, pulmonary and renal complications was same between the off-pump and on-pump groups. PMID:27648039

  5. Quantitative analysis of arterial flow properties for detection of non-calcified plaques in ECG-gated coronary CT angiography

    NASA Astrophysics Data System (ADS)

    Wei, Jun; Zhou, Chuan; Chan, Heang-Ping; Chughtai, Aamer; Agarwal, Prachi; Kuriakose, Jean; Hadjiiski, Lubomir; Patel, Smita; Kazerooni, Ella

    2015-03-01

    We are developing a computer-aided detection system to assist radiologists in detection of non-calcified plaques (NCPs) in coronary CT angiograms (cCTA). In this study, we performed quantitative analysis of arterial flow properties in each vessel branch and extracted flow information to differentiate the presence and absence of stenosis in a vessel segment. Under rest conditions, blood flow in a single vessel branch was assumed to follow Poiseuille's law. For a uniform pressure distribution, two quantitative flow features, the normalized arterial compliance per unit length (Cu) and the normalized volumetric flow (Q) along the vessel centerline, were calculated based on the parabolic Poiseuille solution. The flow features were evaluated for a two-class classification task to differentiate NCP candidates obtained by prescreening as true NCPs and false positives (FPs) in cCTA. For evaluation, a data set of 83 cCTA scans was retrospectively collected from 83 patient files with IRB approval. A total of 118 NCPs were identified by experienced cardiothoracic radiologists. The correlation between the two flow features was 0.32. The discriminatory ability of the flow features evaluated as the area under the ROC curve (AUC) was 0.65 for Cu and 0.63 for Q in comparison with AUCs of 0.56-0.69 from our previous luminal features. With stepwise LDA feature selection, volumetric flow (Q) was selected in addition to three other luminal features. With FROC analysis, the test results indicated a reduction of the FP rates to 3.14, 1.98, and 1.32 FPs/scan at sensitivities of 90%, 80%, and 70%, respectively. The study indicated that quantitative blood flow analysis has the potential to provide useful features for the detection of NCPs in cCTA.

  6. Diagnostic value of plasma morphology in patients with coronary heart disease

    NASA Astrophysics Data System (ADS)

    Malinova, Lidia I.; Sergeeva, Yuliya V.; Simonenko, Georgy V.; Tuchin, Valery V.; Denisova, Tatiana P.

    2006-08-01

    Blood plasma can be considered as a special water system with self-organization possibilities. Plasma slides as the results of wedge dehydration reflect its stereochemical interaction and their study can be used in diagnostic processes. 46 patients with coronary heart disease were studied. The main group was formed of men in age ranged from 54 to 72 years old with stable angina pectoris of II and III functional class (by Canadian classification) (n=25). The group of compare was of those who was hospitalized with diagnosis of acute coronary syndrome, men in age range 40-82. Clinical examination, basic biochemical tests and functional plasma morphology characteristics were studied. A number of qualitative and quantitative differences of blood plasma morphology of patients with chronic and acute coronary disease forms was revealed.

  7. When is rotational angiography superior to conventional single-plane angiography for planning coronary angioplasty?

    PubMed

    Morris, Paul D; Taylor, Jane; Boutong, Sara; Brett, Sarah; Louis, Amal; Heppenstall, James; Morton, Allison C; Gunn, Julian P

    2016-03-01

    To investigate the value of rotational coronary angiography (RoCA) in the context of percutaneous coronary intervention (PCI) planning. As a diagnostic tool, RoCA is associated with decreased patient irradiation and contrast use compared with conventional coronary angiography (CA) and provides superior appreciation of three-dimensional anatomy. However, its value in PCI remains unknown. We studied stable coronary artery disease assessment and PCI planning by interventional cardiologists. Patients underwent either RoCA or conventional CA pre-PCI for planning. These were compared with the referral CA (all conventional) in terms of quantitative lesion assessment and operator confidence. An independent panel reanalyzed all parameters. Six operators performed 127 procedures (60 RoCA, 60 conventional CA, and 7 crossed-over) and assessed 212 lesions. RoCA was associated with a reduction in the number of lesions judged to involve a bifurcation (23 vs. 30 lesions, P < 0.05) and a reduction in the assessment of vessel caliber (2.8 vs. 3.0 mm, P < 0.05). RoCA improved confidence assessing lesion length (P = 0.01), percentage stenosis (P = 0.02), tortuosity (P < 0.04), and proximity to a bifurcation (P = 0.03), particularly in left coronary artery cases. X-ray dose, contrast agent volume, and procedure duration were not significantly different. Compared with conventional CA, RoCA augments quantitative lesion assessment, enhances confidence in the assessment of coronary artery disease and the precise details of the proposed procedure, but does not affect X-ray dose, contrast agent volume, or procedure duration. © 2015 The Authors. Catheterization and Cardiovascular Interventions. Published by Wiley Periodicals, Inc.

  8. Failure to Integrate Quantitative Measurement Methods of Ocular Inflammation Hampers Clinical Practice and Trials on New Therapies for Posterior Uveitis.

    PubMed

    Herbort, Carl P; Tugal-Tutkun, Ilknur; Neri, Piergiorgio; Pavésio, Carlos; Onal, Sumru; LeHoang, Phuc

    2017-05-01

    Uveitis is one of the fields in ophthalmology where a tremendous evolution took place in the past 25 years. Not only did we gain access to more efficient, more targeted, and better tolerated therapies, but also in parallel precise and quantitative measurement methods developed allowing the clinician to evaluate these therapies and adjust therapeutic intervention with a high degree of precision. Objective and quantitative measurement of the global level of intraocular inflammation became possible for most inflammatory diseases with direct or spill-over anterior chamber inflammation, thanks to laser flare photometry. The amount of retinal inflammation could be quantified by using fluorescein angiography to score retinal angiographic signs. Indocyanine green angiography gave imaging insight into the hitherto inaccessible choroidal compartment, rendering possible the quantification of choroiditis by scoring indocyanine green angiographic signs. Optical coherence tomography has enabled measurement and objective monitoring of retinal and choroidal thickness. This multimodal quantitative appraisal of intraocular inflammation represents an exquisite security in monitoring uveitis. What is enigmatic, however, is the slow pace with which these improvements are integrated in some areas. What is even more difficult to understand is the fact that clinical trials to assess new therapeutic agents still mostly rely on subjective parameters such as clinical evaluation of vitreous haze as a main endpoint; whereas a whole array of precise, quantitative, and objective modalities are available for the design of clinical studies. The scope of this work was to review the quantitative investigations that improved the management of uveitis in the past 2-3 decades.

  9. Percutaneous transaortic occlusion of patent ductus arteriosus using a new versatile angiographic and delivery catheter.

    PubMed

    Lorber, A; Gazit, A Z; Khoury, A; Schwartz, Y; Freudental, F

    2003-01-01

    We evaluated the usefulness of patent ductus arteriosus (PDA) occlusion using a new catheter that combines good angiographic properties, easy manipulation across the duct, documentation of aortic and pulmonary artery pressure, and coil delivery for percutaneous transaortic ductal occlusion. Thirty patients (13 females and 17 males) who met the clinical and echocardiographic criteria for the percutaneous closure of PDA were catheterized. The patients selected for this study had a small to moderate PDA with a conal or tubular shape, adequate aortic ampula, and normal or mildly elevated pulmonary artery pressure. The median age was 4.8 years (range, 10 months-20 years). Patients were catheterized by the transaortic approach using the new angiographic and coil delivery catheter specially designed for this procedure. A PDA was closed in every case. A single DuctOcclud pfm coil was delivered in 28 patients, and 2 patients had NitOcclud pfm coils for ductal occlusion. The screening time was measured and found to be 50% less than the measured screening time using other catheters in our laboratory. Only one catheter and one guidewire were used per procedure, with no need for exchange wires or the establishment of an arteriovenous loop. The procedure time was also reduced by 50%. A minimal residual shunt, demonstrated by color-flow Doppler mapping, was present in 2 patients. The new combined angiographic and coil delivery catheter is most suitable for transaortic PDA coil occlusion, significantly decreasing the procedure and screening time.

  10. High-Sensitivity Troponin I Levels and Coronary Artery Disease Severity, Progression, and Long-Term Outcomes.

    PubMed

    Samman Tahhan, Ayman; Sandesara, Pratik; Hayek, Salim S; Hammadah, Muhammad; Alkhoder, Ayman; Kelli, Heval M; Topel, Matthew; O'Neal, Wesley T; Ghasemzadeh, Nima; Ko, Yi-An; Gafeer, Mohamad Mazen; Abdelhadi, Naser; Choudhary, Fahad; Patel, Keyur; Beshiri, Agim; Murtagh, Gillian; Kim, Jonathan; Wilson, Peter; Shaw, Leslee; Vaccarino, Viola; Epstein, Stephen E; Sperling, Laurence; Quyyumi, Arshed A

    2018-02-21

    The associations between high-sensitivity troponin I (hsTnI) levels and coronary artery disease (CAD) severity and progression remain unclear. We investigated whether there is an association between hsTnI and angiographic severity and progression of CAD and whether the predictive value of hsTnI level for incident cardiovascular outcomes is independent of CAD severity. In 3087 patients (aged 63±12 years, 64% men) undergoing cardiac catheterization without evidence of acute myocardial infarction, the severity of CAD was calculated by the number of major coronary arteries with ≥50% stenosis and the Gensini score. CAD progression was assessed in a subset of 717 patients who had undergone ≥2 coronary angiograms >3 months before enrollment. Patients were followed up for incident all-cause mortality and incident cardiovascular events. Of the total population, 11% had normal angiograms, 23% had nonobstructive CAD, 20% had 1-vessel CAD, 20% had 2-vessel CAD, and 26% had 3-vessel CAD. After adjusting for age, sex, race, body mass index, smoking, hypertension, diabetes mellitus history, and renal function, hsTnI levels were independently associated with the severity of CAD measured by the Gensini score (log 2 ß=0.31; 95% confidence interval, 0.18-0.44; P <0.001) and with CAD progression (log 2 ß=0.36; 95% confidence interval, 0.14-0.58; P =0.001). hsTnI level was also a significant predictor of incident death, cardiovascular death, myocardial infarction, revascularization, and cardiac hospitalizations, independent of the aforementioned covariates and CAD severity. Higher hsTnI levels are associated with the underlying burden of coronary atherosclerosis, more rapid progression of CAD, and higher risk of all-cause mortality and incident cardiovascular events. Whether more aggressive treatment aimed at reducing hsTnI levels can modulate disease progression requires further investigation. © 2018 The Authors. Published on behalf of the American Heart Association, Inc

  11. Chaotic behavior of the coronary circulation.

    PubMed

    Trzeciakowski, Jerome; Chilian, William M

    2008-05-01

    The regulation of the coronary circulation is a complex paradigm in which many inputs that influence vasomotor tone have to be integrated to provide the coronary vasomotor adjustments to cardiac metabolism and to perfusion pressure. We hypothesized that the integration of many disparate signals that influence membrane potential of smooth muscle cells, calcium sensitivity of contractile filaments, receptor trafficking result in complex non-linear characteristics of coronary vasomotion. To test this hypothesis, we measured an index of vasomotion, flowmotion, the periodic fluctuations of flow that reflect dynamic changes in resistances in the microcirculation. Flowmotion was continuously measured in periods ranging from 15 to 40 min under baseline conditions, during antagonism of NO synthesis, and during combined purinergic and NOS antagonism in the beating heart of anesthetized open-chest dogs. Flowmotion was measured in arterioles ranging from 80 to 135 microm in diameter. The signals from the flowmotion measurements were used to derive quantitative indices of non-linear behavior: power spectra, chaotic attractors, correlation dimensions, and the sum of the Lyapunov exponents (Kolmogorov-Sinai entropy), which reflects the total chaos and unpredictability of flowmotion. Under basal conditions, the coronary circulation demonstrated chaotic non-linear behavior with a power spectra showing three principal frequencies in flowmotion. Blockade of nitric oxide synthase or antagonism of purinergic receptors did not affect the correlation dimensions, but significantly increased the Kolmogorov-Sinai entropy, altered the power spectra of flowmotion, and changed the nature of the chaotic attractor. These changes are consistent with the view that certain endogenous controls, nitric oxide and various purines (AMP, ADP, ATP, adenosine) make the coronary circulation more predictable, and that blockade of these controls makes the control of flow less predictable and more chaotic.

  12. Angiographic assessment of initial balloon angioplasty results.

    PubMed

    Gardiner, Geoffrey A; Sullivan, Kevin L; Halpern, Ethan J; Parker, Laurence; Beck, Margaret; Bonn, Joseph; Levin, David C

    2004-10-01

    To determine the influence of three factors involved in the angiographic assessment of balloon angioplasty-interobserver variability, operator bias, and the definition used to determine success-on the primary (technical) results of angioplasty in the peripheral arteries. Percent stenosis in 107 lesions in lower-extremity arteries was graded by three independent, experienced vascular radiologists ("observers") before and after balloon angioplasty and their estimates were compared with the initial interpretations reported by the physician performing the procedure ("operator") and an automated quantitative computer analysis. Observer variability was measured with use of intraclass correlation coefficients and SD. Differences among the operator, observers, and the computer were analyzed with use of the Wilcoxon signed-rank test and analysis of variance. For each evaluator, the results in this series of lesions were interpreted with three different definitions of success. Estimation of residual stenosis varied by an average range of 22.76% with an average SD of 8.99. The intraclass correlation coefficients averaged 0.59 for residual stenosis after angioplasty for the three observers but decreased to 0.36 when the operator was included as the fourth evaluator. There was good to very good agreement among the three independent observers and the computer, but poor correlation with the operator (P

  13. Serial Multimodality Imaging and 2-Year Clinical Outcomes of the Novel DESolve Novolimus-Eluting Bioresorbable Coronary Scaffold System for the Treatment of Single De Novo Coronary Lesions.

    PubMed

    Abizaid, Alexandre; Costa, Ricardo A; Schofer, Joachim; Ormiston, John; Maeng, Michael; Witzenbichler, Bernhard; Botelho, Roberto V; Costa, J Ribamar; Chamié, Daniel; Abizaid, Andrea S; Castro, Juliana P; Morrison, Lynn; Toyloy, Sara; Bhat, Vinayak; Yan, John; Verheye, Stefan

    2016-03-28

    This study sought to report the late multimodality imaging and clinical outcomes of the novel poly-l-lactic-acid-based DESolve novolimus-eluting bioresorbable coronary scaffold for the treatment of de novo coronary lesions. Bioresorbable scaffolds are an alternative to drug-eluting metallic stents and provide temporary vascular scaffolding, which potentially may allow vessel restoration and reduce the risk of future adverse events. Overall, 126 patients were enrolled at 13 international sites between November 2011 and June 2012. The primary endpoint was in-scaffold late lumen loss at 6 months. Major adverse cardiac events, the main safety endpoint, were defined as the composite of cardiac death, target vessel myocardial infarction, or clinically indicated target lesion revascularization. All patients underwent angiography at 6 months. Serial intravascular ultrasound and optical coherence tomography were performed in a subset of patients. The scaffold device success rate was 97% (n = 122 of 126), and procedural success was 100% (n = 122 of 122). The major adverse cardiac event rate was 3.3% (n = 4 of 122) at 6 months and 7.4% (n = 9 of 122) at 24 months, including 1 probable stent thrombosis within the first month. At 6-month angiographic follow-up, in-scaffold late lumen loss was 0.20 ± 0.32 mm. Paired intravascular ultrasound analysis demonstrated a significant increase in vessel, lumen and scaffold dimensions between post-procedure and 6-month follow-up, and strut-level optical coherence tomography analysis showed full strut coverage in 99 ± 1.7%. Our results showed favorable performance of the DESolve scaffold, effective inhibition of neointimal hyperplasia, and for the first time, early luminal and scaffold growth at 6 months with sustained efficacy and safety through 2 years. (Elixir Medical Clinical Evaluation of the DESolve Novolimus Eluting Bioresorbable Coronary Scaffold System-The DESolve Nx Trial; NCT02086045). Copyright © 2016 American College of

  14. Beneficial effects of intracoronary nicorandil on microvascular dysfunction after primary percutaneous coronary intervention: demonstration of its superiority to nitroglycerin in a cross-over study.

    PubMed

    Ito, Noritoshi; Nanto, Shinsuke; Doi, Yasuji; Kurozumi, Yuma; Natsukawa, Tomoaki; Shibata, Hiroyuki; Morita, Masaya; Kawata, Atsushi; Tsuruoka, Ayumu; Sawano, Hirotaka; Okada, Ken-ichiro; Sakata, Yasuhiko; Kai, Tatsuro; Hayashi, Toru

    2013-08-01

    In patients undergoing primary percutaneous coronary intervention (PCI) for the treatment of ST-segment elevation myocardial infarction (STEMI), coronary microvascular dysfunction is associated with poor prognosis. Coronary microvascular resistance is predominantly regulated by ATP-sensitive potassium (KATP) channels. The aim of this study was to clarify whether nicorandil, a hybrid KATP channel opener and nitric oxide donor, may be a good candidate for improving microvascular dysfunction even when administered after primary PCI. We compared the beneficial effects of nicorandil and nitroglycerin on microvascular function in 60 consecutive patients with STEMI. After primary PCI, all patients received single intracoronary administrations of nitroglycerin (250 μg) and nicorandil (2 mg) in a randomized order; 30 received nicorandil first, while the other 30 received nitroglycerin first. Microvascular dysfunction was evaluated with the index of microcirculatory resistance (IMR), defined as the distal coronary pressure multiplied by the hyperemic mean transit time. As a first administration, nicorandil decreased IMR significantly more than did nitroglycerin (median [interquartile ranges]: 10.8[5.2-20.7] U vs. 2.1[1.0-6.0] U, p=0.0002).As a second administration, nicorandil further decreased IMR, while nitroglycerin did not (median [interquartile ranges]: 6.0[1.3-12.7] U vs. -1.4[-2.6 to 1.3] U, p<0.0001). The IMR after the second administration was significantly associated with myocardial blush grade, angiographic TIMI frame count after the procedure, and peak creatine kinase level. Intracoronary nicorandil reduced microvascular dysfunction after primary PCI more effectively than did nitroglycerin in patients with STEMI, probably via its KATP channel-opening effect.

  15. Manual Thrombus Aspiration and the Improved Survival of Patients With Unstable Angina Pectoris Treated With Percutaneous Coronary Intervention (30 Months Follow-Up).

    PubMed

    Yildiz, Bekir S; Bilgin, Murat; Zungur, Mustafa; Alihanoglu, Yusuf I; Kilic, Ismail D; Buber, Ipek; Ergin, Ahmet; Kaftan, Havane A; Evrengul, Harun

    2016-02-01

    The clinical effect of intracoronary thrombus aspiration during percutaneous coronary intervention in patients with unstable angina pectoris is unknown. In this study, we aimed to assess how thrombus aspiration during percutaneous coronary intervention affects in-hospital and 30-month mortality and complications in patients with unstable angina pectoris.We undertook an observational cohort study of 645 consecutive unstable angina pectoris patients who had performed percutaneous coronary intervention from February 2011 to March 2013. Before intervention, 159 patients who had culprit lesion with thrombus were randomly assigned to group 1 (thrombus aspiration group) and group 2 (stand-alone percutaneous coronary intervention group). All patients were followed-up 30 months until August 2015.Thrombus aspiration was performed in 64 patients (46%) whose cardiac markers (ie, creatinine kinase [CK-MB] mass and troponin T) were significantly lower after percutaneous coronary intervention than in those of group 2 (CK-MB mass: 3.80 ± 1.11 vs 4.23 ± 0.89, P = 0.012; troponin T: 0.012 ± 0.014 vs 0.018 ± 0.008, P = 0.002). Left ventricular ejection fraction at 6, 12, and 24 months postintervention was significantly higher in the group 1. During a mean follow-up period of 28.87 ± 6.28 months, mortality rates were 6.3% in the group 1 versus 12.9% in the group 2. Thrombus aspiration was also associated with significantly less long-term mortality in unstable angina pectoris patients (adjusted HR: 4.61, 95% CI: 1.16-18.21, P = 0.029).Thrombus aspiration in the context of unstable angina pectoris is associated with a limited elevation in cardiac enzymes during intervention that minimises microembolization and significantly improves both of epicardial flow and myocardial perfusion, as shown by angiographic TIMI flow grade and frame count. Thrombus aspiration during percutaneous coronary intervention in unstable angina pectoris patients has better

  16. Usefulness of Circulating Decoy Receptor 3 in Predicting Coronary Artery Disease Severity and Future Major Adverse Cardiovascular Events in Patients With Multivessel Coronary Artery Disease.

    PubMed

    Chang, Ting-Yung; Hsu, Chien-Yi; Huang, Po-Hsun; Chiang, Chia-Hung; Leu, Hsin-Bang; Huang, Chin-Chou; Chen, Jaw-Wen; Lin, Shing-Jong

    2015-10-01

    Decoy receptor 3 (DcR3), a member of the tumor necrosis factor receptor superfamily, is an antiapoptotic soluble receptor considered to play an important role in immune modulation and has pro-inflammatory functions. This study was designed to test whether circulating DcR3 levels are associated with coronary artery disease (CAD) severity and predict future major adverse cardiovascular events (MACEs) in patients with CAD. Circulating DcR3 levels and the Syntax score (SXscore) were determined in patients with multivessel CAD. The primary end point was the MACE within 12 months. In total, 152 consecutive patients with angiographically confirmed multivessel CAD who had received percutaneous coronary intervention were enrolled and were divided into 3 groups according to CAD lesion severity. Group 1 was defined as low SXscore (≤13), group 2 as intermediate SXscore (>13 and ≤22), and group 3 as high SXscore (>22). DcR3 levels were significantly higher in the high SXscore group than the other 2 groups (13,602 ± 7,256 vs 8,025 ± 7,789 vs 4,637 ± 4,403 pg/ml, p <0.001). By multivariate analysis, circulating DcR3 levels were identified as an independent predictor for high SXscore (adjusted odds ratio 1.15, 95% confidence interval 1.09 to 1.21; p <0.001). The Kaplan-Meier analysis showed that increased circulating DcR3 levels are associated with enhanced 1-year MACE in patients with multivessel CAD (log-rank p <0.001). In conclusion, increased circulating DcR3 levels are associated with CAD severity and predict future MACE in patients with multivessel CAD. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. A comparison of hybrid coronary revascularization and off-pump coronary revascularization.

    PubMed

    Umakanthan, Ramanan; Leacche, Marzia; Gallion, Anna H; Byrne, John G

    2013-04-01

    Minimally invasive approaches to treat vascular disease have been accruing significant popularity over the last several decades. Due to progressive advances in technology, a variety of techniques are being now utilized in the field of cardiovascular surgery. The objectives of minimally invasive techniques are to curtail operative trauma and minimize perioperative morbidity without decreasing the quality of the treatment. The standard surgical approach for the treatment of coronary artery disease has traditionally been coronary artery bypass grafting surgery via median sternotomy. Off-pump coronary artery bypass grafting surgery offers a less invasive alternative and enables coronary revascularization to be performed without cardiopulmonary bypass. Hybrid coronary revascularization offers an even less invasive option in which minimally invasive direct coronary artery bypass can be combined with percutaneous coronary intervention. In this article, the authors review a recent publication comparing hybrid coronary revascularization and off-pump coronary artery bypass grafting surgery.

  18. [Relationship between coronary tortuosity and coronary microvascular disease].

    PubMed

    Wang, Z Y; Wang, Y B; Hao, G Z; Jiang, Y F; Gu, X S; Fan, W Z; Gong, Q; Wang, Q; Fu, X H

    2018-05-24

    Objective: To explore the relationship between coronary tortuosity and coronary microvascular disease (CMVD). Methods: Patients with typical angina symptoms and without serious coronary artery stenosis by coronary angiography were enrolled from June 2014 to December 2016, and CMVD was diagnosed by single photon emission tomography (SPECT). According to the SPECT results, patients were divided to the CMVD group and non-CMVD group. The baseline clinical characteristics, results of coronary angiography were compared between the two groups. The logistic analysis was used to analyze the relationship between coronary tortuosity and CMVD. Result: A total of 117 cases were enrolled, with 69 cases in the CMVD group and 48 cases in the non-CMVD group. No differences were found in gender distribution, age, hypertension, lipid abnormality, hyperuricemia and uses of statins between the two groups (all P >0.05). Incidence of diabetes (78.26%(54/69) vs. 35.42% (17/48) , P <0.05), hs-CRP ((4.29±2.15)mmol/L vs. (2.63±1.20)mmol/L, P <0.001), LDL-C ((2.98±0.96)mmol/L vs. (2.52±0.83)mmol/L, P= 0.008) and homocysteine ((13.7±5.61)mmol/L vs. (11.5±4.38)mmol/L, P= 0.025) levels were higher in the CMVD group than in the non-CMVD group. The data derived from echocardiographic examination were similar between the two groups. The Corrected TIMI frame counts were higher in the CMVD group than in non-CMVD group (LAD: 31.56±4.92 vs. 27.31±3.75, LCX: 29.47±4.18 vs. 26.62±3.19, RCA: 29.09±5.05 vs. 26.24±3.28, all P <0.001). The incidences of coronary atherosclerosis (76.81% (53/69) vs. 27.08% (13/48) , P <0.001) and coronary tortuosity ( (60.87% (42/69) vs. 33.33% (16/48) , P= 0.035) were also higher in the CMVD group than in non-CMVD group. Logistic analysis found that coronary tortuosity ( OR= 6.111, 95% CI 2.707-13.794, P <0.001), diabetes ( OR= 6.565, 95% CI 2.883-14.948, P <0.001) and coronary atherosclerosis ( OR= 8.918, 95% CI 3.822-20.808, P <0.001) were independent risk

  19. The incidence of coronary anomalies on routine coronary computed tomography scans

    PubMed Central

    Karabay, Kanber Ocal; Yildiz, Abdulmelik; Bagirtan, Bayram; Geceer, Gurkan; Uysal, Ender

    2013-01-01

    Summary Objective This study aimed to assess the incidence of coronary anomalies using 64-multi-slice coronary computed tomography (MSCT). Methods The diagnostic MSCT scans of 745 consecutive patients were reviewed. Results The incidence of coronary anomalies was 4.96%. The detected coronary anomalies included the conus artery originating separately from the right coronary sinus (RCS) (n = 8, 1.07%), absence of the left main artery (n = 7, 0.93%), a superior right coronary artery (RCA) (n = 7, 0.93%), the circumflex artery (CFX) arising from the RCS (n = 4, 0.53%), the CFX originating from the RCA (n = 2, 0.26%), a posterior RCA (n = 1, 0.13%), a coronary fistula from the left anterior descending artery and RCA to the pulmonary artery (n = 1, 0.13%), and a coronary aneurysm (n = 1, 0.13%). Conclusions This study indicated that MSCT can be used to detect common coronary anomalies, and shows it has the potential to aid cardiologists and cardiac surgeons by revealing the origin and course of the coronary vessels. PMID:24042853

  20. Translation, adaptation and validation of the Coronary Revascularization Outcome Questionnaire into Greek.

    PubMed

    Takousi, Maria G; Schmeer, Stefanie; Manaras, Irene; Olympios, Christoforos D; Fakiolas, Constantine N; Makos, Georgios; Troop, Nick A

    2016-04-01

    Evaluating the impact of coronary revascularization on patients' health related quality of life with a patient-based and disease-specific tool is important for drawing conclusions about treatment and outcomes. This study reports on the translation, adaptation and psychometric evaluation of a Greek version of the Coronary Revascularization Outcome Questionnaire (CROQ-Gr). A total of 609 (81.7% male) patients who had undergone coronary revascularization (percutaneous coronary intervention or coronary artery bypass grafting) were recruited from four hospitals in Athens. After translating the CROQ into Greek, a preliminary qualitative study and a pilot quantitative study were conducted. A full psychometric evaluation was carried out on the main study's data. The psychometric evaluation demonstrated that the CROQ-Gr is acceptable to patients (high response rate, low missing data) and has a good level of reliability (internal consistency >0.70, test-retest reliability >0.90) and validity (both content and construct validity). The results of this study show the CROQ-Gr to be a psychometrically rigorous patient-based measure of outcomes of coronary revascularization. It would be appropriate for use in evaluative research as well as a routine clinical tool to aid cardiologists in monitoring the outcomes of care. © The European Society of Cardiology 2015.

  1. The Impact of Financial Crisis in Coronary Artery Disease Burden in Greece.

    PubMed

    Sanidas, Elias A; Papaioannou, Theodoros G; Papadopoulos, Dimitrios P; Tatsi, Konstantina; Velliou, Maria; Dalianis, Nikolaos; Paizis, Ioannis; Anastasiadis, George; Kelepesis, Glaukos; Bonou, Maria; Tsioufis, Kontantinos; Barbetseas, John

    2018-03-27

    Economic crisis poses an immense threat to public health worldwide and has been linked to cardiovascular morbidity and mortality. Greece is facing a distinctive recession over the recent years. However, the exact impact on coronary artery disease (CAD) burden has not been adequately addressed. Demographic, clinical and angiographic data of 3895 hospitalized patients were retrospectively studied. Patients were classified in those before crisis (2006-2007, n=1228) and those during crisis (2011-2015, n=2667). All data before and during crisis were compared. During crisis, patients presented with less acute coronary syndromes (ACS - 45.5% vs 39.9%, p<0.001). Subsequently, there were more patients without CAD (23.7% vs 35.1%, p<0.001) or one vessel disease (20.5% vs 23%, p<0.001). The prevalence of traditional risk factors decreased significantly or remained stable except obesity (26.3% vs 31.4%, p=0.002). A significant increase of the examined females (23.6% vs 26.7%, p=0.04) was also observed. The extend of CAD during financial crisis was partially affected. Even though the incidence of ACS was decreased, more women and more patients with no or single vessel disease were led for cardiac catheterization. In addition, the prevalence of traditional risk factors for CAD did not increase except obesity confirming the "obesity paradox". It seems that the impact of traditional risk factors for CAD is not an immediate process and is somewhat related to living conditions or other exogenous and social factors. Copyright © 2018 Hellenic Society of Cardiology. Published by Elsevier B.V. All rights reserved.

  2. Serum levels of vaspin and visfatin in patients with coronary artery disease-Kozani study.

    PubMed

    Kadoglou, Nikolaos P E; Gkontopoulos, Argirios; Kapelouzou, Alkistis; Fotiadis, Grigorios; Theofilogiannakos, Efstratios K; Kottas, George; Lampropoulos, Stilianos

    2011-01-14

    The association of novel adipokines, vaspin and visfatin, with atherosclerosis is still obscure. The present study aimed to investigate the relationship of those adipokines with the existence as well as the extent of coronary artery disease (CAD), suggesting a link between adiposity and atherosclerosis. We enrolled a total of 108 patients with angiographically proven stable, asymptomatic CAD and 65 healthy controls (HC) without cardiovascular diseases. The severity of CAD was assessed using coronary angiography by the Gensini score. Clinical parameters, glycemic and lipid profile, high-sensitivity CRP (hsCRP), vaspin and visfatin levels were assayed. Serum levels of vaspin were significantly lower in subjects with CAD [0.91 (0.44-1.29) ng/ml] than healthy controls [1.42 (0.96-2.42) ng/ml] (p = 0.009). Inversely, visfatin (p = 0.016) and hsCRP (p < 0.001) levels were considerably up-regulated in CAD vs HC group. Multivariate analysis demonstrated decreased vaspin and increased visfatin levels to correlate with CAD presence, independent of other cardiovascular risk factors (p < 0.05). Standard multiple regression revealed HDL, LDL-C and vaspin to be independent determinants of Gensini score (R² = 0.189, p = 0.019). Notably, statin-free patients had even lower vaspin levels compared to statin users (p = 0.018). Decreased vaspin and increased visfatin serum levels were observed in asymptomatic patients with CAD. Low vaspin concentrations seemed to correlate with CAD severity. Copyright © 2010 Elsevier B.V. All rights reserved.

  3. Fractional flow reserve and coronary bifurcation anatomy: a novel quantitative model to assess and report the stenosis severity of bifurcation lesions.

    PubMed

    Tu, Shengxian; Echavarria-Pinto, Mauro; von Birgelen, Clemens; Holm, Niels R; Pyxaras, Stylianos A; Kumsars, Indulis; Lam, Ming Kai; Valkenburg, Ilona; Toth, Gabor G; Li, Yingguang; Escaned, Javier; Wijns, William; Reiber, Johan H C

    2015-04-20

    The aim of this study was to develop a new model for assessment of stenosis severity in a bifurcation lesion including its core. The diagnostic performance of this model, powered by 3-dimensional quantitative coronary angiography to predict the functional significance of obstructive bifurcation stenoses, was evaluated using fractional flow reserve (FFR) as the reference standard. Development of advanced quantitative models might help to establish a relationship between bifurcation anatomy and FFR. Patients who had undergone coronary angiography and interventions in 5 European cardiology centers were randomly selected and analyzed. Different bifurcation fractal laws, including Murray, Finet, and HK laws, were implemented in the bifurcation model, resulting in different degrees of stenosis severity. A total of 78 bifurcation lesions in 73 patients were analyzed. In 51 (65%) bifurcations, FFR was measured in the main vessel. A total of 34 (43.6%) interrogated vessels had an FFR≤0.80. Correlation between FFR and diameter stenosis was poor by conventional straight analysis (ρ=-0.23, p<0.001) but significantly improved by bifurcation analyses: the highest by the HK law (ρ=-0.50, p<0.001), followed by the Finet law (ρ=-0.49, p<0.001), and the Murray law (ρ=-0.41, p<0.001). The area under the receiver-operating characteristics curve for predicting FFR≤0.80 was significantly higher by bifurcation analysis compared with straight analysis: 0.72 (95% confidence interval: 0.61 to 0.82) versus 0.60 (95% confidence interval: 0.49 to 0.71; p=0.001). Applying a threshold of ≥50% diameter stenosis, as assessed by the bifurcation model, to predict FFR≤0.80 resulted in 23 true positives, 27 true negatives, 17 false positives, and 11 false negatives. The new bifurcation model provides a comprehensive assessment of bifurcation anatomy. Compared with straight analysis, identification of lesions with preserved FFR values in obstructive bifurcation stenoses was improved

  4. Evaluation of interpolation methods for surface-based motion compensated tomographic reconstruction for cardiac angiographic C-arm data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mueller, Kerstin; Schwemmer, Chris; Hornegger, Joachim

    2013-03-15

    Purpose: For interventional cardiac procedures, anatomical and functional information about the cardiac chambers is of major interest. With the technology of angiographic C-arm systems it is possible to reconstruct intraprocedural three-dimensional (3D) images from 2D rotational angiographic projection data (C-arm CT). However, 3D reconstruction of a dynamic object is a fundamental problem in C-arm CT reconstruction. The 2D projections are acquired over a scan time of several seconds, thus the projection data show different states of the heart. A standard FDK reconstruction algorithm would use all acquired data for a filtered backprojection and result in a motion-blurred image. In thismore » approach, a motion compensated reconstruction algorithm requiring knowledge of the 3D heart motion is used. The motion is estimated from a previously presented 3D dynamic surface model. This dynamic surface model results in a sparse motion vector field (MVF) defined at control points. In order to perform a motion compensated reconstruction, a dense motion vector field is required. The dense MVF is generated by interpolation of the sparse MVF. Therefore, the influence of different motion interpolation methods on the reconstructed image quality is evaluated. Methods: Four different interpolation methods, thin-plate splines (TPS), Shepard's method, a smoothed weighting function, and a simple averaging, were evaluated. The reconstruction quality was measured on phantom data, a porcine model as well as on in vivo clinical data sets. As a quality index, the 2D overlap of the forward projected motion compensated reconstructed ventricle and the segmented 2D ventricle blood pool was quantitatively measured with the Dice similarity coefficient and the mean deviation between extracted ventricle contours. For the phantom data set, the normalized root mean square error (nRMSE) and the universal quality index (UQI) were also evaluated in 3D image space. Results: The quantitative evaluation

  5. Connecting the coronaries: How the coronary plexus develops and is functionalized

    PubMed Central

    Dyer, Laura; Pi, Xinchun; Patterson, Cam

    2015-01-01

    The establishment of the coronary circulation is one of the final critical steps during heart development. Despite decades of research, our understanding of how the coronary vasculature develops and connects to the aorta remains limited. This review serves two specific purposes: it addresses recent advances in understanding the origin of the coronary endothelium, and it then focuses on the last crucial step of coronary vasculature development, the connection of the coronary plexus to the aorta. The chick and quail animal models have yielded most of the information for how these connections form, starting with a fine network of vessels that penetrate the aorta and coalesce to form two distinct ostia. Studies in mouse and rat confirm that at least some of these steps are conserved in mammals, but gaps still exist in our understanding of mammalian coronary ostia formation. The signaling cues necessary to guide the coronary plexus to the aorta are also incompletely understood. Hypoxia-inducible transcription factor-1 and its downstream targets are among the few identified genes that promote the formation of the coronary stems. Together, this review summarizes our current knowledge of coronary vascular formation and highlights the significant gaps that remain. In addition, it highlights some of the coronary artery anomalies known to affect human health, demonstrating that even seemingly subtle defects arising from incorrect coronary plexus formation can result in significant health crises. PMID:25173872

  6. Geographic and demographic variabilities of quantitative parameters in stress myocardial computed tomography perfusion.

    PubMed

    Park, Jinoh; Kim, Hyun-Sook; Hwang, Hye Jeon; Yang, Dong Hyun; Koo, Hyun Jung; Kang, Joon-Won; Kim, Young-Hak

    2017-09-01

    To evaluate the geographic and demographic variabilities of the quantitative parameters of computed tomography perfusion (CTP) of the left ventricular (LV) myocardium in patients with normal coronary artery on computed tomography angiography (CTA). From a multicenter CTP registry of stress and static computed tomography, we retrospectively recruited 113 patients (mean age, 60 years; 57 men) without perfusion defect on visual assessment and minimal (< 20% of diameter stenosis) or no coronary artery disease on CTA. Using semiautomatic analysis software, quantitative parameters of the LV myocardium, including the myocardial attenuation in stress and rest phases, transmural perfusion ratio (TPR), and myocardial perfusion reserve index (MPRI), were evaluated in 16 myocardial segments. In the lateral wall of the LV myocardium, all quantitative parameters except for MPRI were significantly higher compared with those in the other walls. The MPRI showed consistent values in all myocardial walls (anterior to lateral wall: range, 25% to 27%; p = 0.401). At the basal level of the myocardium, all quantitative parameters were significantly lower than those at the mid- and apical levels. Compared with men, women had significantly higher values of myocardial attenuation and TPR. Age, body mass index, and Framingham risk score were significantly associated with the difference in myocardial attenuation. Geographic and demographic variabilities of quantitative parameters in stress myocardial CTP exist in healthy subjects without significant coronary artery disease. This information may be helpful when assessing myocardial perfusion defects in CTP.

  7. Sirolimus‐eluting stent treatment for unprotected versus protected left main coronary artery disease in widespread clinical routine: 6‐month and 3‐year clinical follow‐up results from the prospective multicentre German Cypher Registry

    PubMed Central

    Khattab, Ahmed A; Hamm, Christian W; Senges, Jochen; Toelg, Ralph; Geist, Volker; Bonzel, Tassilo; Kelm, Malte; Levenson, Benny; Neumann, Franz‐Josef; Nienaber, Christoph A; Pfannebecker, Thomas; Sabin, Georg; Schneider, Steffen; Tebbe, Ulrich; Richardt, Gert

    2007-01-01

    Background Percutaneous coronary intervention (PCI) of left main coronary artery (LMCA) disease in the bare stent era was limited by high restenosis rates which eventually resulted in sudden death in unprotected cases. Clinical and angiographic restenosis has been substantially reduced by drug‐eluting stents, reviving therefore this indication for PCI despite the absence of direct comparative studies with coronary artery bypass graft surgery. Objective To assess the acute, mid‐ and long‐term outcomes of patients treated with sirolimus‐eluting stents for unprotected LMCA stenoses and to compare them with those treated for protected LMCA disease in the same time period from the German Cypher Registry. Setting and patients The German Cypher Registry included 6755 patients. Eighty‐two patients treated for unprotected LMCA disease were compared with 118 patients treated for protected LMCA stenoses. All patients were treated by sirolimus‐eluting stents. The primary end point was death, myocardial infarction (MI) and target vessel revascularisation at 6 months' follow‐up. Survival free of MI at the long term was considered as the safety end point. Results One‐third of the patients in both groups were treated for the distal left main bifurcation. Angiographic success was 98.5% for both groups. The cumulative combined incidence of all‐cause death, non‐fatal MI and target vessel revascularisation at 6 months was 14.1% in the unprotected LMCA group and 13.1% in the protected group (hazard ratio = 0.81 (95% CI 0.37 to 1.74), p = 0.8). At long‐term, death/MI were reported among 20.2% (95% CI 13.5% to 29.6%) of the protected group versus 11.8% (95% CI 6.3% to 21.4%) of the unprotected group (p = 0.2). Conclusion Sirolimus‐eluting stent treatment of unprotected and protected LMCA stenoses is technically feasible in widespread routine clinical use. Acceptable long‐term clinical results can be achieved, with no particular safety concerns

  8. Anomalous origin of right coronary artery from left coronary sinus.

    PubMed

    Hamzeh, Gadah; Crespo, Alex; Estarán, Rafael; Rodríguez, Miguel A; Voces, Roberto; Aramendi, José I

    2008-08-01

    Anomalous aortic origin of the coronary arteries is uncommon but clinically significant. Manifestations vary from asymptomatic patients to those who present with angina pectoris, myocardial infarction, heart failure, syncope, arrhythmias, and sudden death. We describe 4 patients, aged 34 to 59 years, who were diagnosed with right coronary artery arising from the left sinus of Valsalva, confirmed by coronary angiography, which was surgically repaired. Three patients presented dyspnea and angina, and one with acute myocardial infarction. At operation, the right coronary artery was dissected at the take-off from the intramural course, and reimplanted into the right sinus of Valsalva. There was no mortality. One patient had associated coronary artery disease that required stent placement postoperatively. This reimplantation technique provides a good physiological and anatomical repair, eliminates a slit-like ostium, avoids compression of the coronary artery between the aorta and the pulmonary artery, and gives superior results to coronary artery bypass grafting or the unroofing technique.

  9. Noninvasive coronary artery angiography using electron beam computed tomography

    NASA Astrophysics Data System (ADS)

    Rumberger, John A.; Rensing, Benno J.; Reed, Judd E.; Ritman, Erik L.; Sheedy, Patrick F., II

    1996-04-01

    Electron beam computed tomography (EBCT), also known as ultrafast-CT or cine-CT, uses a unique scanning architecture which allows for multiple high spatial resolution electrocardiographic triggered images of the beating heart. A recent study has demonstrated the feasibility of qualitative comparisons between EBCT derived 3D coronary angiograms and invasive angiography. Stenoses of the proximal portions of the left anterior descending and right coronary arteries were readily identified, but description of atherosclerotic narrowing in the left circumflex artery (and distal epicardial disease) was not possible with any degree of confidence. Although these preliminary studies support the notion that this approach has potential, the images overall were suboptimal for clinical application as an adjunct to invasive angiography. Furthermore, these studies did not examine different methods of EBCT scan acquisition, tomographic slice thicknesses, extent of scan overlap, or other segmentation, thresholding, and interpolation algorithms. Our laboratory has initiated investigation of these aspects and limitations of EBCT coronary angiography. Specific areas of research include defining effects of cardiac orientation; defining the effects of tomographic slice thickness and intensity (gradient) versus positional (shaped based) interpolation; and defining applicability of imaging each of the major epicardial coronary arteries for quantitative definition of vessel size, cross-sectional area, taper, and discrete vessel narrowing.

  10. Effects of a 3D segmental prosthetic system for tricuspid valve annulus remodelling on the right coronary artery: a human cadaveric coronary angiography study.

    PubMed

    Riki-Marishani, Mohsen; Gholoobi, Arash; Sazegar, Ghasem; Aazami, Mathias H; Hedjazi, Aria; Sajjadian, Maryam; Ebrahimi, Mahmoud; Aghaii-Zade Torabi, Ahmad

    2017-09-01

    A prosthetic system to repair secondary tricuspid valve regurgitation was developed. The conceptual engineering of the current device is based on 3D segmental remodelling of the tricuspid valve annulus in lieu of reductive annuloplasty. This study was designed to investigate the operational safety of the current prosthetic system with regard to the anatomical integrity of the right coronary artery (RCA) in fresh cadaveric human hearts. During the study period, from January to April 2016, the current prosthetic system was implanted on the tricuspid valve annulus in fresh cadaveric human hearts that met the study's inclusion criteria. The prepared specimens were investigated via selective coronary angiography of the RCA in the catheterization laboratory. The RCA angiographic anatomies were categorized as normal, distorted, kinked or occluded. Sixteen specimens underwent implantation of the current prosthetic system. The mean age of the cadaveric human hearts was 43.24 ± 15.79 years, with vehicle accident being the primary cause of death (59%). A dominant RCA was noticed in 62.5% of the specimens. None of the specimens displayed any injury, distortion, kinking or occlusion in the RCA due to the implantation of the prostheses. In light of the results of the present study, undertaken on fresh cadaveric human heart specimens, the current segmental prosthetic system for 3D remodelling of the tricuspid valve annulus seems to be safe vis-à-vis the anatomical integrity of the RCA. Further in vivo studies are needed to investigate the functional features of the current prosthetic system with a view to addressing the complex pathophysiology of secondary tricuspid valve regurgitation. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  11. Sub-clinical assessment of atopic dermatitis severity using angiographic optical coherence tomography

    PubMed Central

    Byers, Robert A.; Maiti, Raman; Danby, Simon G.; Pang, Elaine J.; Mitchell, Bethany; Carré, Matt J.; Lewis, Roger; Cork, Michael J.; Matcher, Stephen J.

    2018-01-01

    Measurement of sub-clinical atopic dermatitis (AD) is important for determining how long therapies should be continued after clinical clearance of visible AD lesions. An important biomarker of sub-clinical AD is epidermal hypertrophy, the structural measures of which often make optical coherence tomography (OCT) challenging due to the lack of a clearly delineated dermal-epidermal junction in AD patients. Alternatively, angiographic OCT measurements of vascular depth and morphology may represent a robust biomarker for quantifying the severity of clinical and sub-clinical AD. To investigate this, angiographic data sets were acquired from 32 patients with a range of AD severities. Deeper vascular layers within skin were found to correlate with increasing clinical severity. Furthermore, for AD patients exhibiting no clinical symptoms, the superficial plexus depth was found to be significantly deeper than healthy patients at both the elbow (p = 0.04) and knee (p<0.001), suggesting that sub-clinical changes in severity can be detected. Furthermore, the morphology of vessels appeared altered in patients with severe AD, with significantly different vessel diameter, length, density and fractal dimension. These metrics provide valuable insight into the sub-clinical severity of the condition, allowing the effects of treatments to be monitored past the point of clinical remission. PMID:29675335

  12. Total Thrombus-formation Analysis System Predicts Periprocedural Bleeding Events in Patients With Coronary Artery Disease Undergoing Percutaneous Coronary Intervention.

    PubMed

    Oimatsu, Yu; Kaikita, Koichi; Ishii, Masanobu; Mitsuse, Tatsuro; Ito, Miwa; Arima, Yuichiro; Sueta, Daisuke; Takahashi, Aya; Iwashita, Satomi; Yamamoto, Eiichiro; Kojima, Sunao; Hokimoto, Seiji; Tsujita, Kenichi

    2017-04-24

    Periprocedural bleeding events are common after percutaneous coronary intervention. We evaluated the association of periprocedural bleeding events with thrombogenicity, which was measured quantitatively by the Total Thrombus-formation Analysis System equipped with microchips and thrombogenic surfaces (collagen, platelet chip [PL]; collagen plus tissue factor, atheroma chip [AR]). Between August 2013 and March 2016, 313 consecutive patients with coronary artery disease undergoing elective percutaneous coronary intervention were enrolled. They were divided into those with or without periprocedural bleeding events. We determined the bleeding events as composites of major bleeding events defined by the International Society on Thrombosis and Hemostasis and minor bleeding events (eg, minor hematoma, arteriovenous shunt and pseudoaneurysm). Blood samples obtained at percutaneous coronary intervention were analyzed for thrombus formation area under the curve (PL 24 -AUC 10 for PL chip; AR 10 -AUC 30 for AR chip) by the Total Thrombus-formation Analysis System and P2Y12 reaction unit by the VerifyNow system. Periprocedural bleeding events occurred in 37 patients. PL 24 -AUC 10 levels were significantly lower in patients with such events than those without ( P =0.002). Multiple logistic regression analyses showed association between low PL 24 -AUC 10 levels and periprocedural bleeding events (odds ratio, 2.71 [1.22-5.99]; P =0.01) and association between PL 24 -AUC 10 and periprocedural bleeding events in 176 patients of the femoral approach group (odds ratio, 2.88 [1.11-7.49]; P =0.03). However, PL 24 -AUC 10 levels in 127 patients of the radial approach group were not significantly different in patients with or without periprocedural bleeding events. PL 24 -AUC 10 measured by the Total Thrombus-formation Analysis System is a potentially useful predictor of periprocedural bleeding events in coronary artery disease patients undergoing elective percutaneous coronary

  13. New congenital coronary artery anomaly - double supply of single left anterior descending coronary artery from the left and right coronary sinuses: a case report.

    PubMed

    Daralammouri, Yunis; Ghannam, Malik; Lauer, Bernward

    2016-08-02

    A normal anatomy of coronary arteries is important to have adequate cardiac muscle blood supply especially during extraneous physical activities. This case report describes a rare coronary anomaly in which the accessory coronary artery arose from the right coronary artery, reentered the left anterior descending coronary artery, and then ran as a single vessel. We present a case of a coronary anomaly in a 47-year-old white man who presented with atypical angina. Computed tomographic angiography and coronary angiography showed a variant of dual left anterior descending coronary artery not previously described. Our patient's accessory coronary artery arose from his right coronary artery. It took an intramuscular course beneath the right ventricular outflow tract in the interventricular septal area to the anterior interventricular sulcus, giving off septal perforators that reentered his medial left anterior descending coronary artery. Both vessels ran after the anastomosis in the anterior interventricular sulcus as a single vessel. We propose that this anomaly represents a new variant of coronary artery anomaly. This coronary artery anomaly does not cause ischemia. Recognition of this coronary anomaly is important in patients undergoing percutaneous coronary intervention or coronary artery bypass graft operations.

  14. One-year clinical outcomes of ultra long apollo polymer-based Paclitaxel-eluting stents in patients with complex, long coronary artery lesions.

    PubMed

    Salarifar, Mojtaba; Kassaian, Seyed Ebrahim; Alidoosti, Mohammad; Haji-Zeinali, Ali Mohammad; Poorhoseini, Hamid Reza; Nematipour, Ebrahim; Amirzadegan, Alireza; Saroukhani, Sepideh

    2011-01-01

    For all the wealth of research comparing the efficacy of the different types of the drug-eluting stent (DES) such as sirolimus-, paclitaxel-, and zotarolimus-eluting stents, there is still a dearth of data on the different brands of each DES type. We aimed to investigate the one-year clinical outcomes, including major adverse cardiac events (MACE), of the use of the ultra long Apollo paclitaxel-eluting stent in patients with long atherosclerotic coronary artery lesions. According to a retrospective review of the Tehran Heart Center Registry of Interventional Cardiology, a single-center nonrandomized computerized data registry in which all adult patients who undergo single or multi-vessel percutaneous coronary intervention (PCI) are enrolled without any specific exclusion criteria, the mixed use of long Apollo paclitaxel-eluting stents and other types of the DES as well as myocardial infarction within forty-eight hours prior to the procedure was excluded. In total, 122 patients were enrolled in the study, and their baseline clinical, angiographic, and procedural characteristics were obtained. In addition, the patients' follow-up data and, most importantly, MACE during a one-year period after intervention were recorded. The mean follow-up duration was 14.1 ± 3.8 months. The one-year clinical follow-up data were obtained in 95.9 % of all the patients. The incidence of MACE was 5.7% during the entire study period. There was 1 death, which occurred during the initial days after PCI. The incidence of non-fatal myocardial infarction was 2.5% (3 cases), including one patient who underwent target vessel revascularization seven months later. Also, 3 patients with single-vessel disease and in-stent restenosis underwent coronary artery bypass grafting between five to ten months later. Our results showed that the Apollo paclitaxel-eluting stent might be regarded as a safe and effective treatment for long coronary lesions.

  15. Features of electrocardiogram in patients with stenosis of the proximal right coronary artery

    PubMed Central

    Koh, Moo Seong; Lee, Jae Hoon; Jeong, Jin Woo; Chung, Jun Young

    2017-01-01

    Background/Aims Prediction of lesions of the proximal right coronary artery (pRCA) through electrocardiogram (ECG) is very important because pRCA occlusion has many complications and a high mortality rate, which has frequently been related with right ventricular infarction. The purpose of this study was to devise a screening tool that takes into account multiple leads from a 12-lead ECG to predict the pRCA lesion. Methods A hundred and fifty-eight patients who were diagnosed as acute coronary syndrome and had a pure lesion of RCA or left circumf lex artery (LCX) by ECGs and angiographic findings were enrolled retrospectively. Forty-eight patients with a pure pRCA occlusion were compared to a control group of 110 patients who were diagnosed as having either a pure mid to distal RCA lesion (57 patients) or a pure LCX lesion (53 patients). Results ECGs of patients in the pRCA group showed more prominent ST depression in lead I (p = 0.001) and ST elevation in V1 (p = 0.002) than in the control group. The combination of ST depression (≤ 0 mm) in I and ST elevation (> 0.5 mm) in V1 was the best diagnostic tool (area under the curve, 0.84). Conclusions ST changes in leads V1 and I allow more accurate prediction of pRCA occlusion than other criteria, such as the difference between ST elevation of leads II and III or vector direction and amplitude. These variables could help to screen for right ventricular infarction before performing reverse ECG and predicting prognosis. PMID:28190326

  16. Features of electrocardiogram in patients with stenosis of the proximal right coronary artery.

    PubMed

    Koh, Moo Seong; Lee, Jae Hoon; Jeong, Jin Woo; Chung, Jun Young

    2017-03-01

    Prediction of lesions of the proximal right coronary artery (pRCA) through electrocardiogram (ECG) is very important because pRCA occlusion has many complications and a high mortality rate, which has frequently been related with right ventricular infarction. The purpose of this study was to devise a screening tool that takes into account multiple leads from a 12-lead ECG to predict the pRCA lesion. A hundred and fifty-eight patients who were diagnosed as acute coronary syndrome and had a pure lesion of RCA or left circumf lex artery (LCX) by ECGs and angiographic findings were enrolled retrospectively. Forty-eight patients with a pure pRCA occlusion were compared to a control group of 110 patients who were diagnosed as having either a pure mid to distal RCA lesion (57 patients) or a pure LCX lesion (53 patients). ECGs of patients in the pRCA group showed more prominent ST depression in lead I ( p = 0.001) and ST elevation in V1 ( p = 0.002) than in the control group. The combination of ST depression (≤ 0 mm) in I and ST elevation (> 0.5 mm) in V1 was the best diagnostic tool (area under the curve, 0.84). ST changes in leads V1 and I allow more accurate prediction of pRCA occlusion than other criteria, such as the difference between ST elevation of leads II and III or vector direction and amplitude. These variables could help to screen for right ventricular infarction before performing reverse ECG and predicting prognosis.

  17. Arterial Switch Operation With and Without Coronary Relocation for Intramural Coronary Arteries.

    PubMed

    Koshiyama, Hiroshi; Nagashima, Mitsugi; Matsumura, Goki; Hiramatsu, Takeshi; Nakanishi, Toshio; Yamazaki, Kenji

    2016-10-01

    The arterial switch operation (ASO) for the transposition of the great arteries (TGA) with intramural coronary arteries has been performed using several techniques to avoid coronary events. We mainly performed ASO without coronary relocation by creating an aortopulmonary fenestration (Imai technique). Coronary circulation was rerouted by covering the aortopulmonary window and coronary orifices with a nonfacing sinus flap. Long-term results have not been reported. We describe our early and late results. Among 551 patients who underwent an ASO between 1985 and 2014, intramural coronary arteries were detected in 15 of them. Coronary arteries were managed using 2 techniques: the double-button method in 5 patients (with unroofing and trapdoor incision in 1 patient) and the Imai technique in 10 patients. There were 3 hospital deaths and 3 deaths after discharge, 5 of which showed coronary complications. Actual survival and freedom from coronary complications at 15 years were 70% and 67%, respectively, with the Imai technique and 40% and 20%, respectively, with the double-button method. Late coronary intervention was performed for a long intramural coronary artery stenosis in 1 patient who underwent the Imai technique. In the others, late aortography showed good patency of the aortopulmonary window and growth of the coronary pouch after the Imai technique. The Imai technique can be an option for coronary management in the presence of high-risk coronary anatomy, particularly distal intramural coronary artery stenosis and inseparable coronary arteries with an almost single orifice. Adequate neopulmonary artery augmentation must be performed to prevent right ventricular outflow stenosis. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Congenital Anomaly of Single Dominant Right Coronary Artery with Hypoplastic Left Coronary Artery.

    PubMed

    Chuang, Cheng-Yen; Chen, Yen-Chou; Cheng, Ho-Shun; Hsieh, Ming-Hsiung

    2015-11-01

    With the popularization of new imaging technology, more people are deciding to undergo non-invasive studies such as multidetector computerized tomography (MDCT) before receiving coronary angiography. For this reason, coronary anomalies of coronary artery are being encountered more frequently. We here report a 68-year-old male presenting with typical angina. The MDCT images suggested chronic total occlusion of the left anterior descending (LAD) artery with collateral circulation from the right coronary artery (RCA). The patient's coronary angiography showed a congenital coronary anomaly with a single dominant RCA supplying the entire coronary circulation of the heart with both LAD and left circumflex artery hypoplasia. Angiography; Anomaly; Computerized tomography; Coronary artery.

  19. Characterisation of clot microstructure properties in stable coronary artery disease.

    PubMed

    Sabra, Ahmed; Lawrence, Matthew James; Aubrey, Robert; Obaid, Daniel; Chase, Alexander; Smith, Dave; Thomas, Phillip; Storton, Sharon; Davies, Gareth R; Hawkins, Karl; Williams, Phylip Rhodri; Morris, Keith; Evans, Phillip Adrian

    2017-01-01

    Coronary artery disease (CAD) is associated with an increased prothrombotic tendency and is also linked to unfavourably altered clot microstructure. We have previously described a biomarker of clot microstructure (d f ) that is unfavourably altered in acute myocardial infarction. The d f biomarker assesses whether the blood will form denser or looser microstructures when it clots. In this study we assessed in patients with stable chest pain whether d f can differentiate between obstructed and unobstructed CAD. A blood sample prior to angiography was obtained from 251 consecutive patients undergoing diagnostic coronary angiography. Patients were categorised based on angiographic findings as presence or absence of obstructive CAD (stenosis ≥50%). The blood sample was assessed using the d f biomarker, standard laboratory markers and platelet aggregometry (Multiplate). A significant difference (p=0.028) in d f was observed between obstructive CAD (1.748±0.057, n=83) and unobstructive CAD (1.732±0.052, n=168), where patients with significant CAD produce denser, more tightly packed clots. d f was also raised in men with obstructive CAD compared with women (1.745±0.055 vs 1.723±0.052, p=0.007). Additionally d f significantly correlated with the platelets response to arachidonic acid as measured by the ASPItest area under the curve readings from platelet aggregometry (correlation coefficient=0.166, p=0.008), a low value of the ASPItest indicating effective aspirin use was associated with looser, less dense clots. For the first time, we characterise clot microstructure, as measured by d f , in patients with stable CAD. d f can potentially be used to risk-stratify patients with stable CAD and assess the efficacy of therapeutic interventions by measuring changes in clot microstructure.

  20. Angiographic Findings and Embolotherapy in Renal Arterial Trauma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sofocleous, Constantinos T., E-mail: constant@pol.net; Hinrichs, Clay; Hubbi, Basil

    Purpose To evaluate the angiographic findings and embolotherapy in the management of traumatic renal arterial injury Methods This is a retrospective review of 22 patients with renal trauma who underwent arteriography and percutaneous embolization from December 1995 to January 2002. Medical records, imaging studies and procedural reports were reviewed to assess the type of injury, arteriographic findings and immediate embolization results. Long-term clinical outcome was obtained by communication with the trauma physicians and by clinical chart review.Results Arteriography was performed in 125 patients admitted to a State Trauma Center with suspected internal bleeding. Renal arterial injury was documented in 22more » and was the result of a motor-vehicle accident (10), auto-pedestrian accident (1), gunshot (4) or stab wounds (6) and a fall (1). Percutaneous renal arterial embolization was undertaken in 22 of 125 (18%) patients to treat extravasation (11), arterial pedicle rupture (5), abnormal arteriovenous (3) or arteriocalyceal (2) communication and pseudoaneurysm (3). One of the pseudoaneurysms and one of the arteriovenous fistulae were found in addition to extravasation. All 22 patients (16 men, 6 women) were hemodynamically stable, or controlled during arteriography and embolotherapy. Selective and/or superselective embolization of the abnormal vessels was performed using coils in 9 patients, microcoils in 9 patients and Gelfoam pledgets in 3 patients. In one patient Gelfoam pledgets mixed with polyvinyl alcohol (PVA) particles were used for embolization. Immediate angiographic evidence of hemostasis was demonstrated in all cases. Two initial technical failures were treated with repeat arteriography and embolization. There was no procedure-related death. There was no non-target embolization. One episode of renal abscess after embolization was treated by nephrectomy and 3 patients underwent elective post-embolization nephrectomy to prevent infection. Follow

  1. Endothelium dependent and independent responses in coronary artery disease measured at angioplasty.

    PubMed Central

    Holdright, D R; Clarke, D; Poole-Wilson, P A; Fox, K; Collins, P

    1993-01-01

    OBJECTIVE--To investigate the effects of substance P and papaverine, two drugs that increase coronary blood flow by different mechanisms, on vasomotion in stenotic coronary arteries at percutaneous transluminal coronary angioplasty (PTCA). DESIGN--Coronary blood flow responses to substance P and papaverine were measured in stenotic coronary arteries at the time of PTCA with quantitative angiography and a Doppler flow probe. SETTING--A cardiothoracic referral centre. PATIENTS--15 patients undergoing elective PTCA of a discrete epicardial coronary artery stenosis. INTERVENTIONS--Pharmacological coronary flow reserve was determined with papaverine 5-10 minutes before and after successful PTCA. Endothelium dependent responses to 2 minute infusions of substance P (10-15 pmol.min-1) were assessed immediately before PTCA. MAIN OUTCOME MEASURES--Coronary blood flow responses and changes in epicardial coronary artery area at stenotic, proximal, and distal sites with papaverine and substance P. RESULTS--Stenotic sites dilated with papaverine before PTCA (17.7%(6.9%) (mean (SEM)) area increase, p < 0.05 v baseline). Substance P dilated stenotic sites (16.8%(5.7%) area increase, p < 0.05) and proximal (14.3%(5.4%), p < 0.05) and distal sites (41.7%(9.3%), p < 0.005). Coronary flow reserve increased but did not reach normal values after PTCA (2.3(0.4) before PTCA v 3.0(0.4) after PTCA, p < 0.05) and was associated with an increase in peak flow with papaverine. Angioplasty did not alter baseline flow. After PTCA papaverine caused significant vasoconstriction at the stenotic site (-13.6%(4.3%) area decrease, p < 0.05). There was a negative correlation (r = -0.68, p < 0.05) between the dilator response with papaverine before PTCA and the constrictor response after PTCA. CONCLUSIONS--Substance P causes endothelium dependent dilatation in atheromatous coronary arteries, even at sites of overt atheroma. The cause of the paradoxical constrictor response to papaverine after PTCA is

  2. Coronary Heart Disease Knowledge and Risk Factors among Tri-Ethnic College Students

    ERIC Educational Resources Information Center

    Koutoubi, Samer; Huffman, Fatma G.; Ciccazzo, Michele W.; Himburg, Susan P.; Johnson, Paulette

    2005-01-01

    Objectives: Coronary heart disease (CHD) is the leading cause of death in the United States and Europe. This study identified and compared nutritional knowledge associated with CHD risk factors among tri-ethnic college students. Design: A quantitative, cross-sectional, observational study using questionnaires. Setting: University laboratory.…

  3. Refractory Coronary Artery Spasm after Minimally Invasive Direct Coronary Artery Bypass Grafting

    PubMed Central

    Ju, Min Ho; Kim, Joon-Bum; Kim, Hee Jung

    2011-01-01

    Postoperative coronary arterial spasm is a rare but potentially fatal complication. A 51-year-old male patient with a history of a reactive ergonovine stress test coronary angiogram developed refractory coronary artery spasm after undergoing minimally invasive direct coronary artery bypass grafting of the left anterior descending coronary artery. The patient was successfully managed with rapid implementation of intra-aortic balloon-pump counter pulsation and extracorporeal membrane oxygenation. PMID:22263171

  4. Optimal Adenosine Stress for Maximum Stress Perfusion, Coronary Flow Reserve, and Pixel Distribution of Coronary Flow Capacity by Kolmogorov-Smirnov Analysis.

    PubMed

    Kitkungvan, Danai; Lai, Dejian; Zhu, Hongjian; Roby, Amanda E; Johnson, Nils P; Steptoe, Derek D; Patel, Monica B; Kirkeeide, Richard; Gould, K Lance

    2017-02-01

    Different adenosine stress imaging protocols have not been systemically validated for absolute myocardial perfusion and coronary flow reserve (CFR) by positron emission tomography, where submaximal stress precludes assessing physiological severity of coronary artery disease. In 127 volunteers, serial rest-stress positron emission tomography scans using rubidium-82 with various adenosine infusion protocols identified (1) the protocol with maximum stress perfusion and CFR, (2) test-retest precision in same subject, (3) stress perfusion and CFR after adenosine compared with dipyridamole, (4) heterogeneity of coronary flow capacity combining stress perfusion and CFR, and (5) potential relevance for patients with risk factors or coronary artery disease. The adenosine 6-minute infusion with rubidium-82 injection at 3 minutes caused CFR that was significantly 15.7% higher than the 4-minute adenosine infusion with rubidium-82 injection at 2 minutes and significantly more homogeneous by Kolmogorov-Smirnov analysis for histograms of 1344 pixel range of perfusion in paired positron emission tomographies. In a coronary artery disease cohort separate from volunteers of this study, compared with the 3/6-minute protocol, the 2/4-minute adenosine protocol would potentially have changed 332 of 1732 (19%) positron emission tomographies at low-risk physiological severity CFR ≥2.3 to CFR <2.0, thereby implying high-risk quantitative severity potentially appropriate for interventions but because of suboptimal stress of the 2/4 protocol in some patients. The 6-minute adenosine infusion with rubidium-82 activation at 3 minutes produced CFR that averaged 15.7% higher than that in the 2/4-minute protocol, thereby potentially providing essential information for personalized management in some patients. © 2017 American Heart Association, Inc.

  5. Medical therapy, percutaneous coronary intervention and prognosis in patients with chronic total occlusions.

    PubMed

    Ladwiniec, Andrew; Allgar, Victoria; Thackray, Simon; Alamgir, Farquad; Hoye, Angela

    2015-12-01

    There is little published data reporting outcomes for those found to have a chronic total coronary occlusion (CTO) that is electively treated medically versus those treated by percutaneous coronary intervention (PCI). We sought to compare long-term clinical outcomes between patients treated by PCI and elective medical therapy in a consecutive cohort of patients with an identified CTO. Patients found to have a CTO on angiography between January 2002 and December 2007 in a single tertiary centre were identified using a dedicated database. Those undergoing CTO PCI and elective medical therapy to the CTO were propensity matched to adjust for baseline clinical and angiographic differences. In total, 1957 patients were identified, a CTO was treated by PCI in 405 (20.7%) and medical therapy in 667 (34.1%), 885 (45.2%) patients underwent coronary artery bypass graft surgery. Of those treated by PCI or medical therapy, propensity score matching identified 294 pairs of patients, PCI was successful in 177 patients (60.2%). All-cause mortality at 5 years was 11.6% for CTO PCI and 16.7% for medical therapy HR 0.63 (0.40 to 1.00, p=0.052). The composite of 5-year death or myocardial infarction occurred in 13.9% of the CTO PCI group and 19.6% in the medical therapy group, HR 0.64 (0.42 to 0.99, p=0.043). Among the CTO PCI group, if the CTO was revascularised by any means during the study period, 5-year mortality was 10.6% compared with 18.3% in those not revascularised in the medical therapy group, HR 0.50 (0.28-0.88, p=0.016). Revascularisation, but not necessarily PCI of a CTO, is associated with improved long-term survival relative to medical therapy alone. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  6. Application of a snare technique in retrograde chronic total occlusion percutaneous coronary intervention – a step by step practical approach and an observational study

    PubMed Central

    Fang, Hsiu-Yu; Lee, Wei-Chieh; Fang, Chih-Yuan; Wu, Chiung-Jen

    2016-01-01

    Abstract Percutaneous coronary intervention (PCI) for chronic total occlusion (CTO) has recently become popular among interventional cardiologists. CTO originating from the ostium has been one of the most difficult CTO lesions to treat with PCI for a number of reasons. Our aim was to illustrate a specific technique during retrograde CTO PCI referred to as the “snare technique.” We retrospectively examined the use of “snare technique” among 371 consecutive retrograde CTO PCIs performed at our institution between 2006 and 2015. “Snare technique” was used in 10 patients among the 371 retrograde CTO PCIs. The baseline clinical and angiographic characteristics of patients with or without “snare technique” were similar. The “snare technique” group had significantly fewer side branches at occlusion (30.0% vs 71.2%, P = 0.01) and a higher incidence of externalization (90% vs 25.5%, P < 0.001). The contrast volume was significantly lower in the “snare technique” group (285.0 ± 68.5 vs 379.2 ± 144.0, P = 0.04). The incidence of major complications, retrograde success, or final success did not differ between the groups. The “snare technique” is safe and feasible in retrograde CTO PCI, especially in cases of difficult coronary engagement in cases such as ostial occlusion, challenging coronary anatomy, or retrograde guidewire cannot get in antegrade guiding catheter. PMID:27741138

  7. Coronary artery disease

    MedlinePlus Videos and Cool Tools

    The coronary arteries supply blood to the heart muscle itself. Damage to or blockage of a coronary artery can result in injury to the heart. Normally, blood flows through a coronary artery unimpeded. However, a ...

  8. Angiographic and epidemiological characteristics associated with aneurysm remnants after microsurgical clipping

    PubMed Central

    Dellaretti, Marcos; da Silva Martins, Warley Carvalho; Dourado, Jules Carlos; Faglioni, Wilson; Quadros, Ricardo Souza; de Souza Moraes, Vítor Vieira; de Souza Filho, Carlos Batista Alves

    2017-01-01

    Background: Despite new techniques for the treatment of cerebral aneurysms, the percentage of aneurysm remnants after surgical intervention seems to be relatively constant. The objective of this study was to assess angiographic and epidemiological features associated with aneurysm remnants after microsurgical clipping. Methods: This study was conducted from February 2009 to August 2012 on a series of 90 patients with 105 aneurysms referred to the Santa Casa of Belo Horizonte who were surgically treated and angiographically controlled. Results: Surgical clipping was considered incomplete in 13.3% of the aneurysms. The mean age of cases with an aneurysm remnant was 57.5 years, whereas the mean age without aneurysm remnant was 49.7 years (P = 0.02). Aneurysm remnants were detected more frequently on the internal carotid artery, nevertheless, no statistically significant differences were verified when comparing the locations. Aneurysm size in the preoperative angiography verified that the mean size of aneurysms operated was 6.56 mm, such that in cases showing a postoperative remnant, the mean size was 9.7 mm and in cases with complete clipping it was 6.08 mm (P = 0.02). Postoperative angiography showed that, in cases with residual aneurysm, the number of clips used was higher – a mean of 1.8 for complete clipping and 3.1 for incomplete clipping (P < 0.001). Conclusions: Aneurysm size and patient age showed significant correlations with residual intracranial aneurysm. The mean number of clips used was higher in cases with incomplete occlusion. PMID:28904825

  9. Novel monorail infusion catheter for volumetric coronary blood flow measurement in humans: in vitro validation.

    PubMed

    van 't Veer, Marcel; Adjedj, Julien; Wijnbergen, Inge; Tóth, Gabor G; Rutten, Marcel C M; Barbato, Emanuele; van Nunen, Lokien X; Pijls, Nico H J; De Bruyne, Bernard

    2016-08-20

    The aim of this study is to validate a novel monorail infusion catheter for thermodilution-based quantitative coronary flow measurements. Based on the principles of thermodilution, volumetric coronary flow can be determined from the flow rate of a continuous saline infusion, the temperature of saline when it enters the coronary artery, and the temperature of the blood mixed with the saline in the distal part of the coronary artery. In an in vitro set-up of the systemic and coronary circulation at body temperature, coronary flow values were varied from 50-300 ml/min in steps of 50 ml/min. At each coronary flow value, thermodilution-based measurements were performed at infusion rates of 15, 20, and 30 ml/min. Temperatures and pressures were simultaneously measured with a pressure/temperature sensor-tipped guidewire. Agreement of the calculated flow and the measured flow as well as repeatability were assessed. A total of five catheters were tested, with a total of 180 measurements. A strong correlation (ρ=0.976, p<0.0001) and a difference of -6.5±15.5 ml/min were found between measured and calculated flow. The difference between two repeated measures was 0.2%±8.0%. This novel infusion catheter used in combination with a pressure/temperature sensor-tipped guidewire allows accurate and repeatable absolute coronary flow measurements. This opens a window to a better understanding of the coronary microcirculation.

  10. Deep learning analysis of the myocardium in coronary CT angiography for identification of patients with functionally significant coronary artery stenosis.

    PubMed

    Zreik, Majd; Lessmann, Nikolas; van Hamersvelt, Robbert W; Wolterink, Jelmer M; Voskuil, Michiel; Viergever, Max A; Leiner, Tim; Išgum, Ivana

    2018-02-01

    In patients with coronary artery stenoses of intermediate severity, the functional significance needs to be determined. Fractional flow reserve (FFR) measurement, performed during invasive coronary angiography (ICA), is most often used in clinical practice. To reduce the number of ICA procedures, we present a method for automatic identification of patients with functionally significant coronary artery stenoses, employing deep learning analysis of the left ventricle (LV) myocardium in rest coronary CT angiography (CCTA). The study includes consecutively acquired CCTA scans of 166 patients who underwent invasive FFR measurements. To identify patients with a functionally significant coronary artery stenosis, analysis is performed in several stages. First, the LV myocardium is segmented using a multiscale convolutional neural network (CNN). To characterize the segmented LV myocardium, it is subsequently encoded using unsupervised convolutional autoencoder (CAE). As ischemic changes are expected to appear locally, the LV myocardium is divided into a number of spatially connected clusters, and statistics of the encodings are computed as features. Thereafter, patients are classified according to the presence of functionally significant stenosis using an SVM classifier based on the extracted features. Quantitative evaluation of LV myocardium segmentation in 20 images resulted in an average Dice coefficient of 0.91 and an average mean absolute distance between the segmented and reference LV boundaries of 0.7 mm. Twenty CCTA images were used to train the LV myocardium encoder. Classification of patients was evaluated in the remaining 126 CCTA scans in 50 10-fold cross-validation experiments and resulted in an area under the receiver operating characteristic curve of 0.74 ± 0.02. At sensitivity levels 0.60, 0.70 and 0.80, the corresponding specificity was 0.77, 0.71 and 0.59, respectively. The results demonstrate that automatic analysis of the LV myocardium in a single

  11. Three-dimensional entertainment as a novel cause of takotsubo cardiomyopathy.

    PubMed

    Taylor, Montoya; Amin, Anish; Bush, Charles

    2011-11-01

    Takotsubo cardiomyopathy (TC) is an uncommon entity. It is known to occur in the setting of extreme catecholamine release and results in left ventricular dysfunction without evidence of angiographically definable coronary artery disease. There have been no published reports of TC occurring with visual stimuli, specifically 3-dimensional (3D) entertainment. We present a 55-year-old woman who presented to her primary care physician's office with extreme palpitations, nausea, vomiting, and malaise <48 hours after watching a 3D action movie at her local theater. Her electrocardiogram demonstrated ST elevations in aVL and V1, prolonged QTc interval, and T-wave inversions in leads I, II, aVL, and V2-V6. Coronary angiography revealed angiographically normal vessels, elevated left ventricular filling pressures, and decreased ejection fraction with a pattern of apical ballooning. The presumed final diagnosis was TC, likely due to visual-auditory-triggered catecholamine release causing impaired coronary microcirculation. © 2011 Wiley Periodicals, Inc.

  12. A spontaneous pre-anastomotic occlusion does not necessarily impair forearm native dialysis fistulas: echo-Doppler, 3D MR angiographic and digital subtraction angiographic imaging.

    PubMed

    Verbeeck, N; Pillet, J C; Prospert, E; McLntyre, D; Lamy, S

    2013-01-01

    Renal transplantation is the choice treatment of end-stage renal disease. When it is not indicated or not immediately feasible, hemodialysis must be performed, preferably via a native arteriovenous fistula in the forearm. A pre-anastomotic occlusion of this type of fistula is often accompanied by a thrombosis of its draining vein. In some instances, the venous segment may remain permeable thanks to the development of arterial collateral pathways and may even allow efficient dialysis without any clinical syndrome of distal steal. We present the echo-Doppler, magnetic and angiographic characteristics of three of these collateralized shunts that have remained functional, in one of the cases following a percutaneous dilation.

  13. Coronary Artery Anomalies in Animals

    PubMed Central

    Scansen, Brian A.

    2017-01-01

    Coronary artery anomalies represent a disease spectrum from incidental to life-threatening. Anomalies of coronary artery origin and course are well-recognized in human medicine, but have received limited attention in veterinary medicine. Coronary artery anomalies are best described in the dog, hamster, and cow though reports also exist in the horse and pig. The most well-known anomaly in veterinary medicine is anomalous coronary artery origin with a prepulmonary course in dogs, which limits treatment of pulmonary valve stenosis. A categorization scheme for coronary artery anomalies in animals is suggested, dividing these anomalies into those of major or minor clinical significance. A review of coronary artery development, anatomy, and reported anomalies in domesticated species is provided and four novel canine examples of anomalous coronary artery origin are described: an English bulldog with single left coronary ostium and a retroaortic right coronary artery; an English bulldog with single right coronary ostium and transseptal left coronary artery; an English bulldog with single right coronary ostium and absent left coronary artery with a prepulmonary paraconal interventricular branch and an interarterial circumflex branch; and a mixed-breed dog with tetralogy of Fallot and anomalous origin of all coronary branches from the brachiocephalic trunk. Coronary arterial fistulae are also described including a coronary cameral fistula in a llama cria and an English bulldog with coronary artery aneurysm and anomalous shunting vessels from the right coronary artery to the pulmonary trunk. These examples are provided with the intent to raise awareness and improve understanding of such defects. PMID:29056679

  14. Outcomes in Elderly Patients With Severely Calcified Coronary Lesions Undergoing Orbital Atherectomy.

    PubMed

    Lee, Michael S; Shlofmitz, Evan; Lluri, Gentian; Shlofmitz, Richard A

    2017-04-01

    We evaluated the clinical outcomes of elderly patients who underwent orbital atherectomy for the treatment of severe coronary artery calcification (CAC) prior to stenting. Percutaneous coronary intervention (PCI) of severe CAC is associated with worse clinical outcomes including death, myocardial infarction (MI), and target vessel revascularization (TVR). The elderly represents a high-risk group of patients, often have more comorbid conditions, and have worse outcomes after PCI compared to younger patients. Clinical trials and a large multicenter registry have demonstrated the safety and efficacy of orbital atherectomy for the treatment of severe CAC. Clinical outcomes of elderly patients who undergo orbital atherectomy are unknown. Of the 458 patients, 229 were ≥75 years old (elderly) and 229 were <75 years old (younger). The primary endpoint was rate of 30-day major adverse cardiac and cerebrovascular events (MACCE), comprised of cardiac death, MI, TVR, and stroke. The primary endpoint was similar in the elderly and younger groups (2.2% vs. 2.2%, P = 1), as were the individual endpoints of death (2.2% vs. 0.4%, P = 0.1), MI (0.9% vs. 1.3%, P = 0.65), TVR (0% vs. 0%, P = 1), and stroke (0% vs. 0.4%, P = 0.32). The rates of angiographic complications and stent thrombosis were similarly low in both groups. The elderly represented a sizeable number of patients who underwent orbital atherectomy. It is a safe and effective treatment strategy for elderly patients with severe CAC as the clinical outcomes were similar to their younger counterparts. A randomized trial should further clarify the role of orbital atherectomy in these patients. © 2017, Wiley Periodicals, Inc.

  15. A comparison of clinical and angiographic outcomes after Excel bioabsorbable polymer versus Firebird durable polymer rapamycin-eluting stent for the treatment of coronary artery disease in a "real world" setting: six-month follow-up results.

    PubMed

    Liu, Hai-bo; Xu, Bo; Qiao, Shu-bin; Yang, Yue-jin; Ma, Wei-hua; Qin, Xue-wen; Yao, Min; Wu, Yong-jian; Yuan, Jin-qing; Chen, Jue; You, Shi-jie; Dai, Jun; Xia, Ran; Li, Jian-jun; Chen, Ji-lin; Gao, Run-lin

    2007-04-05

    Several clinical trials have shown that rapamycin-eluting stents significantly reduce the risk of restenosis after percutaneous coronary intervention (PCI). The Firebird stent and the Excel stent (coated with bioabsorbable polymer) are two different types of rapamycin-eluting stents made in China, both have been recently approved for clinical use in China by State Food and Drug Administration. However, it is unclear whether there are differences in safety and efficacy between the two types of stents in daily practice. In the month of June 2006, a total of 190 consecutive patients were treated exclusively with Firebird stents (n = 93, Firebird group) or Excel stents (n = 97, Excel group) in our center and were included in this study. The frequency of major adverse cardiac events (MACE, a composite of death, myocardial infarction or target lesion revascularization), binary restenosis, and late lumen loss and stent thrombosis during a six-month follow-up period were compared between the two groups. Patient and lesion characteristics were comparable between the groups. Major adverse cardiac event rates were low in hospital and at 6 months (2.1% in the Excel group and 0% in the Firebird group, P > 0.05). The 6-month angiographic in-stent restenosis rate was 0% in both groups, with an associated late loss of (0.15 +/- 0.21) mm versus (0.14 +/- 0.20) mm (P = 0.858) and the in-segment restenosis rate was also 0% for the Excel group and the Firebird group. There was no definite stent thrombosis identified in either group during the six-month follow-up period and only one patient in the Excel group had probable stent thrombosis in hospital. Results from this mid-term, single-center study showed that both of the Firebird and the Excel rapamycin eluting stent had similar effects on reducing the incidence of MACE and the risk of restenosis (both in-stent and in-segment binary restenosis) after PCI in daily practice.

  16. Coronary atherosclerosis evaluation among Iranian patients with zero coronary calcium score in computed tomography coronary angiography.

    PubMed

    Moradi, Maryam; Varasteh, Elham

    2016-01-01

    Coronary artery calcification (CAC) is a specific indicator of and a sensitive marker for the atherosclerotic disease process. However, calcium scoring may miss noncalcified plaques with clinical importance. The present study aimed to identify the presence and extent of coronary plaques in computed tomography coronary angiography (CTCA) in patients with a zero CAC score and the secondary endpoint was to evaluate the association between coronary risk factors and the presence of noncalcified plaques. In a retrospective descriptive-analytic study, a total of 2000 consecutive patients who undergone CTCA between September 2012 and September 2014 at Alzahra Hospital in Isfahan, Iran were analyzed. Three hundred and eighty-five patients with a zero calcium score were included in the study. The demographic information and coronary artery disease (CAD), risk factors including diabetes mellitus (DM), hypertension, hyperlipidemia, smoking, and family history of CAD, were obtained from the questionnaire. Furthermore, the presence of plaques and extent of stenosis were evaluated in patients with zero CAC score. Of the 385 patients with a zero calcium score, 16 (4.2%) had atherosclerotic plaques. Among them, 6 (1.6%) had significant (>50%) coronary stenosis, and 10 (2.6%) had no significant (<50%) coronary stenosis. Hyperlipidemia, DM, and smoking were significantly associated with obstructive CAD. Furthermore, in patients with zero calcium score, DM, hyperlipidemia, and smoking had odds ratios of 5.9, 14, and 32.5 for the development of coronary artery plaques, respectively. Although, CAC scoring is a noninvasive and valuable method to evaluate CAD; but zero CAC score does not absolutely exclude the CAD, especially in the presence of risk factors such as diabetes, hyperlipidemia, and smoking.

  17. Use of Mixed Methods Research in Research on Coronary Artery Disease, Diabetes Mellitus, and Hypertension: A Scoping Review.

    PubMed

    Campbell, David J T; Tam-Tham, Helen; Dhaliwal, Kirnvir K; Manns, Braden J; Hemmelgarn, Brenda R; Sanmartin, Claudia; King-Shier, Kathryn

    2017-01-01

    Mixed methods research, the use of both qualitative and quantitative methods within 1 program of study, is becoming increasingly popular to allow investigators to explore patient experiences (qualitative) and also measure outcomes (quantitative). Coronary artery disease and its risk factors are some of the most studied conditions; however, the extent to which mixed methods studies are being conducted in these content areas is unknown. We sought to comprehensively describe the characteristics of published mixed methods studies on coronary artery disease and major risk factors (diabetes mellitus and hypertension). We conducted a scoping review of the literature indexed in PubMed, Medline, EMBASE, and CINAHL. We identified 811 abstracts for screening, of which 254 articles underwent full-text review and 97 reports of 81 studies met criteria for inclusion. The majority of studies in this area were conducted in the past 10 years by nurse researchers from the United States and United Kingdom. Diabetes mellitus was the most common content area for mixed methods investigation (compared with coronary artery disease and hypertension). Most authors described their rationale for using mixed methods as complementarity and did not describe study priority or how they reconciled differences in methodological paradigms. Some mixed methods study designs were more commonly used than others, including concurrent timing and integration at the interpretation stage. Qualitative strands were most commonly descriptive studies using interviews for data collection. Quantitative strands were most commonly cross-sectional observational studies, which relied heavily on self-report data such as surveys and scales. Although mixed methods research is becoming increasingly popular in the area of coronary artery disease and its risk factors, many of the more advanced mixed methods, qualitative, and quantitative techniques have not been commonly used in these areas. © 2016 American Heart Association

  18. Comparison of no-reflow phenomenon after percutaneous coronary intervention for acute myocardial infarction between smokers and nonsmokers.

    PubMed

    Shemirani, Hassan; Tafti, Faezeh Dehghani; Amirpour, Afshin

    2014-11-01

    No-reflow phenomenon after percutaneous coronary intervention (PCI) in patients with acute ST-segment-elevation myocardial infarction (STEMI) is relatively common and has therapeutic and prognostic implications. Cigarette smoking is known as deleterious in patients with coronary artery disease (CAD), but the effect of smoking on no-reflow phenomenon is less investigated. The aim of this study was to compare no-reflow phenomenon after percutneous coronary intervention for acute myocardial infarction, between smokers and non smokers. A total of 141 patients who were admitted to Chamran Hospital (Isfahan, Iran) between March and September, 2012 with a diagnosis of STEMI, enrolled into our Cohort study. Patients were divided into current smoker and nonsmoker groups (based on patient's information). All patients underwent primary PCI or rescue PCI within the first 12-h of chest pain. No-reflow phenomenon, thrombolysis in myocardial infarction (MI) flow, and 24-h complications were assessed in both groups. A total of 47 current smoker cases (32.9%) and 94 (65.7%) nonsmoker cases were evaluated. Smokers in comparison to nonsmokers were younger (53.47 ± 10.59 vs. 61.46 ± 10.55, P < 0.001) and they were less likely to be hypertensive (15.2% vs. 44.7%, P < 0.001), diabetic (17% vs. 36.2%, P < 0.05), and female gender (4.3% vs. 25.5%, P < 0.01). Angiographic and procedural characteristics of both groups were similar. 9 patients died during the first 24-h after PCI (4.3% of smokers and 6.4% of nonsmokers, P: 0.72). No-reflow phenomenon was observed in 29.8% of current smokers and 31.5% of nonsmokers (P = 0.77). No-reflow phenomenon or short-term complications were not significantly different between current smokers and non smokers.

  19. Integration of Quantitative Positron Emission Tomography Absolute Myocardial Blood Flow Measurements in the Clinical Management of Coronary Artery Disease.

    PubMed

    Gewirtz, Henry; Dilsizian, Vasken

    2016-05-31

    In the >40 years since planar myocardial imaging with(43)K-potassium was introduced into clinical research and management of patients with coronary artery disease (CAD), diagnosis and treatment have undergone profound scientific and technological changes. One such innovation is the current state-of-the-art hardware and software for positron emission tomography myocardial perfusion imaging, which has advanced it from a strictly research-oriented modality to a clinically valuable tool. This review traces the evolving role of quantitative positron emission tomography measurements of myocardial blood flow in the evaluation and management of patients with CAD. It presents methodology, currently or soon to be available, that offers a paradigm shift in CAD management. Heretofore, radionuclide myocardial perfusion imaging has been primarily qualitative or at best semiquantitative in nature, assessing regional perfusion in relative terms. Thus, unlike so many facets of modern cardiovascular practice and CAD management, which depend, for example, on absolute values of key parameters such as arterial and left ventricular pressures, serum lipoprotein, and other biomarker levels, the absolute levels of rest and maximal myocardial blood flow have yet to be incorporated into routine clinical practice even in most positron emission tomography centers where the potential to do so exists. Accordingly, this review focuses on potential value added for improving clinical CAD practice by measuring the absolute level of rest and maximal myocardial blood flow. Physiological principles and imaging fundamentals necessary to understand how positron emission tomography makes robust, quantitative measurements of myocardial blood flow possible are highlighted. © 2016 American Heart Association, Inc.

  20. Apolipoprotein E genotype in matched men and women with coronary heart disease.

    PubMed

    Kolovou, Genovefa D; Anagnostopoulou, Katherine K; Salpea, Klelia D; Panagiotakos, Demosthenes B; Hoursalas, Ioannis S; Cariolou, Marios A; Koniavitou, Katerina; Cokkinos, Dennis V

    2005-01-01

    Apolipoprotein E (apo E) plays an important role in lipid metabolism and its polymorphism may be a risk determinant of coronary heart disease (CHD). Since evidence suggested a gender-specific effect of apo E polymorphism, we studied the influence of gender-specific interaction of the polymorphism on CHD. From a total of 463 Greek Caucasians (314 men and 149 postmenopausal women) with angiographically documented CHD, we selected 79 women (68+/- 9 yr old) and 79 men (66+/- 9 yr old) who were matched for clinical characteristics. Apo E genotyping was performed by PCR and RFLP analysis. Biochemical parameters were also measured. The results were as follows: the E3/3 genotype occurred in 78.5% of the patients, followed by E3/4, E2/3, E2/4, and E4/4 genotypes, which occurred in 9.5%, 9.5%, 1.9%, and 0.6% of the patients, respectively. No significant differences were observed in the apo E allele or apo E genotype distributions between the matched Greek men and women with CHD. The E3/3 men patients were more frequently part of a family with a history of CHD, compared to women (p=0.035).

  1. Coronary Artery Disease | Coronary Artery Disease | NIH MedlinePlus the Magazine

    MedlinePlus

    ... of this page please turn Javascript on. Feature: Coronary Artery Disease Coronary Artery Disease Past Issues / Fall 2010 Table of Contents David ... up inside your arteries. One atherosclerosis-related disease, coronary artery disease (CAD) is the most common heart disease and ...

  2. Clinical experience with the Monorail balloon catheter for coronary angioplasty.

    PubMed

    Finci, L; Meier, B; Roy, P; Steffenino, G; Rutishauser, W

    1988-01-01

    The Monorail balloon catheter is distinctly different from other current balloon catheters: the guidewire passes through the balloon itself, exits the catheter proximal to the balloon, and runs alongside its small shaft (3 French) through the guiding catheter. Monorail coronary angioplasty was attempted in 61 patients on 73 lesions with balloons from 2.0 to 3.7 mm. Angiographic success was obtained in 66 lesions (90%). For 15 lesions, balloon exchanges were needed. In three lesions, the Monorail balloon failed to cross the lesion, while a standard balloon succeeded; two lesions could not be crossed with any balloon. Vessel occlusion occurred in four patients: two had emergency surgery without infarct (one died suddenly 4 days later and one had a stroke 1 day later), one was recanalized with a standard balloon, and one had a myocardial infarct. Continuous infusion of urokinase was used until patient 3 in whom problems with the delivery system led to cardiocerebral air embolization (with complete recovery). No thrombotic complications were observed in the subsequent 58 patients with only a bolus of 10,000 U of heparin. The Monorail balloon facilitates contrast injections and balloon exchanges but appears more difficult to pass through tight lesions. Omission of the previously recommended infusion with a thrombolytic agent proved safe.

  3. Regulation of coronary blood flow. Effect of coronary artery stenosis.

    PubMed

    Duncker, D J; Merkus, D

    2004-12-01

    The consistently high level of myocardial oxygen extraction requires tight control of coronary blood flow, because an increase in myocardial oxygen demand, as occurs during exercise, cannot be obtained by a further increase in oxygen extraction. Consequently, adequate control of coronary vascular resistance is critical. Coronary resistance vessel tone is the result of a myriad of vasodilator and vasoconstrictor influences, which are exerted by the myocardium, endothelium and neurohumoral status. Unraveling of the integrative mechanisms controlling metabolic vasodilation has been difficult, more than likely due to the redundancy design of vasomotor control. In contrast to the traditional view that myocardial ischemia produced by a coronary artery stenosis causes maximal microvascular dilation, more recent studies have shown that the coronary microvessels retain some degree of vasodilator reserve during ischemia and remain responsive to vasoconstrictor stimuli. These observations raise the question of whether pharmacologic vasodilators acting at the microvascular level might be therapeutically useful. The critical property of effective vasodilator therapy requires selective dilation of small arteries, while avoiding coronary steal by not interfering with metabolic vasoregulation at the level of the arterioles.

  4. Coronary surgery and coronary angioplasty in patients with two-vessel coronary artery disease.

    PubMed

    Weintraub, W S; King, S B; Jones, E L; Douglas, J S; Craver, J M; Liberman, H A; Morris, D C; Guyton, R A

    1993-03-01

    There is uncertainty regarding the selection between coronary artery surgery and angioplasty in many patients with coronary artery disease, especially in those with 2-vessel disease. Whereas randomized trials will provide the best possible and most detailed data comparing therapy in these patients, clinical data bases may be used to provide a current perspective. The purpose of this study was to compare the long-term outcome of patients with 2-vessel coronary artery disease undergoing coronary surgery or angioplasty at Emory University hospitals in the years 1984 and 1985. Data on all patients with 2-vessel disease diagnosed at Emory University who underwent elective angioplasty or coronary surgery in the years 1984 and 1985 were compared. Categoric variables were analyzed by chi-square and continuous variables by unpaired t test. Survival was determined by the Kaplan-Meier method and differences in survival by the Mantel-Cox method. Determinants of survival were determined by Cox model analysis. There were 415 angioplasty patients and 454 surgical patients. Surgical patients were older and had more frequent systemic hypertension, diabetes mellitus, prior myocardial infarction, severe angina and congestive failure, and more significant narrowing in the left anterior descending coronary artery, totally occluded vessels and left ventricular dysfunction than did angioplasty patients. Complete revascularization was achieved more often in surgical patients. There was no difference in Q-wave myocardial infarction in the hospital. No angioplasty patient died compared with 1.1% of surgical patients (p = 0.03). Whereas 5-year survival was 93% in angioplasty patients and 89% in surgical patients (p = 0.11), there was no difference in risk-adjusted survival.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Financial impact of coronary stenting in emergency for acute coronary syndromes.

    PubMed

    Nidegger, Delphine; Metz, Damien; Vacter, Christophe; Tassan-Mangina, Sophie; Deschildre, Alain; Gawron, Michel; Bourgeois, Jacqueline

    2009-05-01

    Since the prospective payment system, health institutions have only specific payments for the emergency care in the emergency room. The direct urgent admissions in coronary care units for acute coronary syndrome (ACS) do not collect this complementary refund. For the patient's stay, hospital is remunerated with fixed national prices which are similar even in case of emergent or planed coronary revascularization when realized. To analyze and compare the financial impact between emergent and planed coronary stenting in the setting of ACS. This retrospective study was based on patients suffering from ACS who experienced emergent coronary stenting during the year 2005. On 154 patients, 127 were age-, sex- and diagnosis-related group (called "groupe homogène de malades" in the French Health Care system)-matched with 127 suffering from same ACS but with planed "ad hoc" coronary stenting. The overall charges (medical and paramedical team, pharmacy, biology, implantable coronary devices, radiology) were compared between the two groups. Mean stay duration was 6.7 days and did not differ between the two groups. Mean financial retributions were significantly higher in the emergent group (7338 euro [6831-7846] IC95 vs 6509 euro [5994-7023]; p=0,02) but with a much more raised consumption (6810 euro [6283-7336] vs 5223 euro [4632-5814]; p=0,001). This overcost was due especially to drugs and biological expenses. The hospitalization payments did not cover the overall expenses for 25% of the patients' stays (N=64) among whom 39 have had emergent coronary stenting (30.7%, p=0.04). Among the different GHM, the most important difference was observed in non-STEMI without complication with a negative receipts/costs ratio for 37.8% of the stay with coronary stenting in emergency. The application of the recent guidelines for coronary revascularization in the management of ACS represents a financial venture for hospital institutions. The engaged charges for emergent coronary stenting

  6. OCT Angiographic Findings in Glucose-6-Phosphate Dehydrogenase Deficiency.

    PubMed

    Jiang, Shangjun; Choudhry, Netan

    2017-08-01

    Fovea plana (FP) describes the abnormal absence of the foveal pit in the retina. It is a sign that is associated with prematurity, albinism, and other ophthalmic disorders. The authors present the optical coherence tomography angiographic findings in a case of a 19-year-old male with FP and glucose-6-phosphate dehydrogenase (G6PD) deficiency. G6PD deficiency is a very common condition that typically presents with hemolytic anemia and jaundice. G6PD deficiency is also known to affect vision, but these pathologies have been less well-characterized. To the authors' knowledge, this is the first report of G6PD deficiency in FP. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:664-667.]. Copyright 2017, SLACK Incorporated.

  7. Impact of maternal dexamethasone on coronary PGE2 production and prostaglandin-dependent coronary reactivity

    PubMed Central

    Volk, Kenneth A.; Lamb, Fred S.; Segar, Jeffrey L.

    2012-01-01

    Intrauterine growth restriction is associated with increased fetal glucocorticoid exposure and an increased risk of adult coronary artery disease. Coronary arteries from sheep exposed to early gestation dexamethasone (Dex) have increased constriction to angiotensin II (ANG II). Prostaglandin E2 (PGE2) helps maintain coronary dilation, but PGE2 production is acutely decreased by Dex administration. We hypothesized early gestation Dex exposure impairs adult coronary PGE2 production with subsequent increases in coronary reactivity. Dex was administered to ewes at 27–28 days gestation (term 145 days). Coronary reactivity was assessed by wire myography in offspring at 4 mo of age (N = 5 to 7). Coronary smooth muscle cells were cultured and prostaglandin production was measured after 90 min incubation with radiolabeled arachidonate. Coronary myocytes from Dex-exposed lambs had a significant decrease in PGE2 production that was reversed with ANG II incubation. Dex-exposed coronary arteries had increased constriction to ANG II and attenuated dilatation to arachidonic acid, with the greatest difference seen after the endothelium was inactivated by rubbing. Preincubation with the cyclooxygenase (COX) inhibitor indomethacin altered control responses and recapitulated the heightened coronary tone seen following Dex exposure. We conclude that impaired coronary smooth muscle COX-mediated PGE2 production contributes to the coronary dysfunction elicited by early gestation Dex. Programmed inhibition of vasodilatory prostanoid production may link an adverse intrauterine environment with adult coronary artery disease. PMID:22832534

  8. Intravascular ultrasound comparison of left main coronary artery disease between white and Asian patients.

    PubMed

    Rusinova, Reni P; Mintz, Gary S; Choi, So-Yeon; Araki, Hiroshi; Hakim, Diaa; Sanidas, Elias; Yakushiji, Tadayuki; Weisz, Giora; Mehran, Roxana; Franklin-Bond, Theresa; Fahy, Martin; Leon, Martin B; Stone, Gregg W; Moses, Jeffery W; Tahk, Seung-Jea; Ochiai, Masahiko; Maehara, Akiko

    2013-04-01

    We assessed the ethnic differences in coronary atherosclerosis lesion morphology between white and Asian patients. Our hypothesis was that left main coronary artery (LMCA) disease was more focal and less complex in Asian than in Western white patients. We studied 99 Asian patients (Japan and South Korea) and 99 matched control United States white patients with a stable clinical presentation and >30% LMCA angiographic diameter stenosis by visual estimation. The matching parameters included age, gender, and diabetes mellitus. The vessel and lumen areas and calcium arc were analyzed every 0.5 mm and normalized for analysis length. Overall, 75.1% of the patients were men and 34.1% had diabetes. The patient age was 68.0 ± 10 years, with no differences between the Asian and white patients. The Asian patients had a lower prevalence of hyperlipidemia than the white patients (41.4% vs 81.8%; p <0.0001) and were smaller in size, and the white patients were more obese (body mass index 23.7 ± 2.6 vs 27.6 ± 4.1 kg/m(2), p <0.0001). The Asian patients had a smaller lumen area (5.2 ± 1.8 vs 6.2 ± 14 mm(2); p <0.0001), larger vessel area (20.0 ± 4.9 vs 18.4 ± 4.4 mm(2); p <0.0001), and larger plaque burden (72 ± 10 vs 64 ± 12%: p <0.0001) at the minimum lumen site and over the entire LMCA length. The white patients had more calcification, whether assessed by the maximum arc (82° ± 74° vs 49° ± 45°; p <0.0001) or total length (3.6 ± 3.2 vs 2.1 ± 2.1 mm; p <0.0001). In conclusion, after matching well-known risk factors, there appeared to be ethnic differences in coronary atherosclerosis morphology between Asian and white patients, at least as it affected LMCA morphology. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Cardiac Medication Use in Patients with Acute Myocardial Infarction and Nonobstructive Coronary Artery Disease.

    PubMed

    Adatia, Falisha; Galway, Shannon; Grubisic, Maja; Lee, May; Daniele, Patrick; Humphries, Karin H; Sedlak, Tara L

    2017-11-01

    Patients with acute myocardial infarction (MI) and nonobstructive coronary artery disease (CAD) have an elevated cardiac event rate, suggesting that these patients may benefit from cardiac medication. We evaluated the rates of cardiac medication use 3 months before angiography and 3 months following clinically indicated angiography for MI in patients with no CAD, nonobstructive CAD, and obstructive CAD. We also examined the sex differences in cardiac medication use 3 months following angiography in patients by extent of angiographic CAD. We studied patients ≥20 years old with MI undergoing coronary angiography in British Columbia, Canada, from January 1, 2008, to March 31, 2010 (n = 3,841). No CAD, nonobstructive CAD, and obstructive CAD were defined as 0%, 1% to 49%, and ≥50% luminal narrowing in any epicardial coronary artery, respectively. Medication use, 3 months before and 3 months following angiography, was obtained through British Columbia PharmaNet for angiotensin-converting enzyme inhibitors (ACE-Is), angiotensin receptor blockers (ARBs), calcium channel blockers (CCBs), beta-blockers, statins, and antiplatelet agents. Optimal medical therapy (OMT) was defined as filled prescriptions for all three: ACE-Is/ARBs, beta-blockers, and statins. Following angiography, in all medication categories except CCBs, patients with no CAD and nonobstructive CAD had significantly lower rates of prescriptions filled than patients with obstructive CAD (all p < 0.001). After adjusting for age and prior medication use, patients with nonobstructive CAD were still less likely to receive these medications than patients with obstructive CAD, including OMT with an odds ratio = 0.25 (95% confidence interval: 0.18-0.36). There were no significant sex differences in medication use 3 months postangiography. In post-MI patients, medication use following angiography is significantly lower in nonobstructive CAD than obstructive CAD at 3 months. While sex was not an

  10. Distribution of angiographic measures of restenosis after drug-eluting stent implantation.

    PubMed

    Byrne, R A; Eberle, S; Kastrati, A; Dibra, A; Ndrepepa, G; Iijima, R; Mehilli, J; Schömig, A

    2009-10-01

    A bimodal distribution of measures of restenosis has been demonstrated at 6-8 months after bare metal stent implantation. Drug-eluting stent (DES) treatment has attenuated the impact of certain factors (eg, diabetes) on restenosis but its effect on the distribution of indices of restenosis is not known. To perform a detailed analysis of the metrics of restenosis indices after DES implantation. Design, settings, Prospective observational study of patients undergoing DES implantation (Cypher, sirolimus-eluting stent; or Taxus, paclitaxel-eluting stent) at two German centres, with repeat angiography scheduled at 6-8 months after coronary stenting. In-stent late luminal loss (LLL) and in-segment percentage diameter stenosis (%DS) as determined by quantitative coronary angiography at recatheterisation. Paired cineangiograms were available for 2057 patients. Overall mean (SD) LLL was 0.31 (0.50) mm; mean (SD) %DS was 30.3 (15.7)%. Distribution of both LLL and %DS differed significantly from normal (Kolmogorov-Smirnov test; p<0.001 for each). For both parameters a mixed distribution model better described the data (likelihood ratio test with 3df; p<0.001 for each). This consisted of two normally distributed subpopulations with means (SD) of 0.10 (0.25) mm and 0.69 (0.60) mm for LLL, and means (SD) of 22.2 (8.6)% and 40.1 (16.6)% for %DS. The results were consistent across subgroups of DES type, "on-label" versus "off-label" indication, and presence or absence of diabetes. LLL and %DS at follow-up angiography after DES implantation have a complex mixed distribution that may be accurately represented by a bimodal distribution model. The introduction of DES treatment has not resulted in elimination of a variable propensity to restenosis among subpopulations of patients with stented lesions.

  11. [Comparison of 64 MDCT coronary CTA and coronary angiography in the detection of coronary artery stenosis in low risk patients with stable angina and acute coronary syndrome].

    PubMed

    Cazalas, G; Sarran, A; Amabile, N; Chaumoitre, K; Marciano-Chagnaud, S; Jacquier, A; Paganelli, F; Panuel, M

    2009-09-01

    To determine the accuracy of 64 MDCT coronary CTA (CCTA) compared to coronary angiography in low risk patients with stable angina and acute coronary syndrome and determine the number of significant coronary artery stenoses ( 50%) in these patients. Materials and methods. Fifty-five patients underwent CCTA using a 32 MDCT unit with z flying focus allowing the acquisition of 64 slices of 0.6 mm thickness as well as coronary angiography (gold standard). Nine patients were excluded due to prior coronary artery bypass surgery (n=4), insufficient breath hold (n=3), calcium scoring>1000 (n=1) and delay between both examinations over 4 months (n=1). Forty-six patients: 27 males and 19 females were included. CCTA results were compared to coronary angiography per segment and artery with threshold detection of stenoses 50%. The degree of correlation between both examinations was performed using a regression analysis with a Pearson correlation coefficient<0.05 considered significant. The overall accuracy of CCTA was 90%; limitations related to the presence of calcifications, motion artifacts or insufficient vessel opacification. The correlation for all analyzed segments was 96.4%. Thirty-eight of 50 significant stenoses seen on coronary angiography were correctly detected on CCTA. Sensitivity, specificity, PPVC and NPV for detection of stenoses 50% were 76%, 98.3%, 80.3% and 97.7% respectively. Evaluation per segment had a NPV of 96.8% (interventricular and diagonal segments) to 100% (main trunk). Our results for specificity and NPV are similar to reports from the literature. This suggests that CCTA in this clinical setting may replace coronary angiography.

  12. Effect of ascorbic acid on endothelial dysfunction of epicardial coronary arteries in chronic smokers assessed by cold pressor testing.

    PubMed

    Schindler, T H; Magosaki, N; Jeserich, M; Olschewski, M; Nitzsche, E; Holubarsch, C; Solzbach, U; Just, H

    2000-01-01

    In chronic smokers there is evidence for increased formation of oxygen-derived free radicals within the vessel wall impairing endothelial function. It has been suggested that the inactivation of endothelium-derived nitric oxide by oxygen free radicals contributes to endothelial dysfunction. Hence, we tested the hypothesis that in chronic smokers the antioxidant ascorbic acid could improve abnormal endothelial function of epicardial coronary arteries. Thirty-one patients (mean age 57 +/- 9 years) referred for routine diagnostic catheterization for evaluation of chest pain and without angiographically significant coronary artery stenoses were randomly assigned to one of the study groups to assess vasomotor response of epicardial coronary arteries due to cold pressor testing (CPT) before and after intravenous infusion of 3 g of ascorbic acid or 100 ml x 0.9% saline infusion. In 6 controls (mean age 55 +/- 3 years) CPT led to a similar increase in luminal area before and after ascorbic acid administration (26.5 +/- 15.0 vs. 28.4 +/- 17.7%, p = NS). In 15 chronic smokers (mean age 55 +/- 9 years), CPT induced a decrease in the luminal area of -18.5 +/- 6.3%. This flow-dependent vasoconstriction was significantly reversed to 7.7 +/- 6.2% (p < or = 0.03) vasodilation after intravenous ascorbic acid administration. In 10 chronic smokers (mean age 57 +/- 11 years) saline infusion (placebo) did not have a significant effect on CPT-induced vasoconstriction (-12.7 +/- 5.1 vs. -13.1 +/- 5.1%, p = NS). The CPT-induced increase in luminal area in chronic smokers after ascorbic acid infusion was significant compared to controls and placebo (each p < or = 0.05). Our assessment of endothelium-independent responses to nitroglycerin revealed no significant differences between the single study groups (p = NS). In chronic smokers acute intravenous administration of ascorbic acid significantly improves CPT-induced coronary endothelium-dependent dysfunction. According to the current

  13. Relationship between inter-arm blood pressure difference and severity of coronary atherosclerosis.

    PubMed

    Park, Se-Jun; Son, Jung-Woo; Park, Sang-Min; Choi, Hyun-Hee; Hong, Kyung-Soon

    2017-08-01

    A greater inter-arm blood pressure difference (IABPD) is associated with atherosclerosis, but its association with coronary artery disease is unknown. We investigated the relationship between IABPD and coronary atherosclerosis. We retrospectively reviewed blood pressure (BP) data that was measured simultaneously in both arms of patients who underwent initial coronary angiography. Coronary atherosclerosis was assessed using the Gensini score, based on quantitative coronary angiography findings. To adjust for the effect of baseline BP, the percentages of systolic IABPD to higher mean BP (cIABPD sys ), diastolic IABPD to higher mean BP (cIABPD dia ), and mean IABPD to higher mean BP (cIABPD mean ) were calculated as BP-adjusted IABPDs. We examined the records of 816 patients (516 males, mean age: 65.5 ± 11.8 years). The mean Gensini score was 33.4 ± 30.4, and the median was 25. All cIAPBDs had positive correlations with the Gensini score (cIABPD sys : r = 0.208, p < 0.001; cIABPD dia : r = 0.123, p < 0.001; cIABPD mean : r = 0.120, p = 0.001). Multiple regression analysis indicated that cIABPD sys was associated with the Gensini score, independently of age, gender, smoking, diabetes, hypertension and dyslipidemia (B = 0.031, p < 0.001). The BP-adjusted IABPD parameters are related to the severity of coronary artery disease. Further studies should investigate the use of the IABPD to improve management of coronary atherosclerosis. Copyright © 2017. Published by Elsevier B.V.

  14. Delayed Contrast-Enhanced MRI of the Coronary Artery Wall in Takayasu Arteritis

    PubMed Central

    Schneeweis, Christopher; Schnackenburg, Bernhard; Stuber, Matthias; Berger, Alexander; Schneider, Udo; Yu, Jing; Gebker, Rolf; Weiss, Robert G.; Fleck, Eckart; Kelle, Sebastian

    2012-01-01

    Background Takayasu arteritis (TA) is a rare form of chronic inflammatory granulomatous arteritis of the aorta and its major branches. Late gadolinium enhancement (LGE) with magnetic resonance imaging (MRI) has demonstrated its value for the detection of vessel wall alterations in TA. The aim of this study was to assess LGE of the coronary artery wall in patients with TA compared to patients with stable CAD. Methods We enrolled 9 patients (8 female, average age 46±13 years) with proven TA. In the CAD group 9 patients participated (8 male, average age 65±10 years). Studies were performed on a commercial 3T whole-body MR imaging system (Achieva; Philips, Best, The Netherlands) using a 3D inversion prepared navigator gated spoiled gradient-echo sequence, which was repeated 34–45 minutes after low-dose gadolinium administration. Results No coronary vessel wall enhancement was observed prior to contrast in either group. Post contrast, coronary LGE on IR scans was detected in 28 of 50 segments (56%) seen on T2-Prep scans in TA and in 25 of 57 segments (44%) in CAD patients. LGE quantitative assessment of coronary artery vessel wall CNR post contrast revealed no significant differences between the two groups (CNR in TA: 6.0±2.4 and 7.3±2.5 in CAD; p = 0.474). Conclusion Our findings suggest that LGE of the coronary artery wall seems to be common in patients with TA and similarly pronounced as in CAD patients. The observed coronary LGE seems to be rather unspecific, and differentiation between coronary vessel wall fibrosis and inflammation still remains unclear. PMID:23236382

  15. Delayed contrast-enhanced MRI of the coronary artery wall in takayasu arteritis.

    PubMed

    Schneeweis, Christopher; Schnackenburg, Bernhard; Stuber, Matthias; Berger, Alexander; Schneider, Udo; Yu, Jing; Gebker, Rolf; Weiss, Robert G; Fleck, Eckart; Kelle, Sebastian

    2012-01-01

    Takayasu arteritis (TA) is a rare form of chronic inflammatory granulomatous arteritis of the aorta and its major branches. Late gadolinium enhancement (LGE) with magnetic resonance imaging (MRI) has demonstrated its value for the detection of vessel wall alterations in TA. The aim of this study was to assess LGE of the coronary artery wall in patients with TA compared to patients with stable CAD. We enrolled 9 patients (8 female, average age 46±13 years) with proven TA. In the CAD group 9 patients participated (8 male, average age 65±10 years). Studies were performed on a commercial 3T whole-body MR imaging system (Achieva; Philips, Best, The Netherlands) using a 3D inversion prepared navigator gated spoiled gradient-echo sequence, which was repeated 34-45 minutes after low-dose gadolinium administration. No coronary vessel wall enhancement was observed prior to contrast in either group. Post contrast, coronary LGE on IR scans was detected in 28 of 50 segments (56%) seen on T2-Prep scans in TA and in 25 of 57 segments (44%) in CAD patients. LGE quantitative assessment of coronary artery vessel wall CNR post contrast revealed no significant differences between the two groups (CNR in TA: 6.0±2.4 and 7.3±2.5 in CAD; p = 0.474). Our findings suggest that LGE of the coronary artery wall seems to be common in patients with TA and similarly pronounced as in CAD patients. The observed coronary LGE seems to be rather unspecific, and differentiation between coronary vessel wall fibrosis and inflammation still remains unclear.

  16. Use of the Impella 2.5 for prophylactic circulatory support during elective high-risk percutaneous coronary intervention.

    PubMed

    Alasnag, Mirvat A; Gardi, Delair O; Elder, Mahir; Kannam, Hari; Ali, Farhan; Petrina, Mircea; Kheterpal, Vipin; Hout, Mariah S; Schreiber, Theodore L

    2011-01-01

    Patients undergoing percutaneous coronary intervention (PCI) who are at high risk for cardiovascular collapse during the procedure may benefit from prophylactic circulatory support. The objective was to evaluate the safety and feasibility of prophylactic use of the Impella 2.5 during high-risk PCI. We used the Impella 2.5 for partial circulatory support during 60 consecutive elective high-risk PCI cases over 20 months. All patients either were deemed inoperable by the cardiac surgeons or were offered bypass surgery but declined. The patients had multiple risk factors including hypertension (95%), diabetes (52%), chronic pulmonary disease (23%), prior myocardial infarction (62%) and prior bypass surgery (18%). Forty-five percent presented with acute coronary syndrome. The mean left ventricular ejection fraction was 23%±15%. Nearly all patients had multivessel disease (93%), and 60% had left main disease. The average SYNTAX score was 30±9. Despite lesion complexity and high-risk factors, we achieved an angiographic success rate of 96%. Left main lesions were treated in 55% of the patients, and 83% of patients had multiple lesions treated. There was one procedural death. At 30 days postintervention, mortality was 5%, and rates of myocardial infarction, stroke, target vessel revascularization and urgent bypass surgery were 0%. The single-center experience reported here demonstrates that use of the Impella 2.5 during high-risk PCI in the "real world" - outside the controlled environment of a clinical trial - is safe and feasible. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Plaque disruption by coronary computed tomographic angiography in stable patients vs. acute coronary syndrome: a feasibility study.

    PubMed

    Bilolikar, Abhay N; Goldstein, James A; Madder, Ryan D; Chinnaiyan, Kavitha M

    2016-03-01

    This study was designed to determine whether coronary CT angiography (CTA) can detect features of plaque disruption in clinically stable patients and to compare lesion prevalence and features between stable patients and those with acute coronary syndrome (ACS). We retrospectively identified patients undergoing CTA, followed by invasive coronary angiography (ICA) within 60 days. Quantitative 3-vessel CTA lesion analysis was performed on all plaques ≥25% stenosis to assess total plaque volume, low attenuation plaque (LAP, <50 HU) volume, and remodelling index. Plaques were qualitatively assessed for CTA features of disruption, including ulceration and intra-plaque dye penetration (IDP). ICA was employed as a reference standard for disruption. A total of 145 (94 ACS and 51 stable) patients were identified. By CTA, plaque disruption was evident in 77.7% of ACS cases. Although more common among those with ACS, CTA also detected plaque disruption in 37.3% of clinically stable patients (P < 0.0001). Clinically stable patients commonly manifest plaques with features of disruption as determined by CTA. Though the prevalence of plaque disruption is less than patients with ACS, these findings support the concept that some clinically stable patients may harbour 'silent' disrupted plaques. These findings may have implications for detection of 'at risk' plaques and patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  18. Effect of Permanent Right Internal Mammary Artery Closure on Coronary Collateral Function and Myocardial Ischemia.

    PubMed

    Stoller, Michael; Seiler, Christian

    2017-06-01

    The objective of this study is to test the effect of permanent right internal mammary artery device closure on coronary collateral function and myocardial ischemia. This was a prospective, open-label clinical trial in 50 patients with coronary artery disease. The primary study end point was coronary collateral flow index as obtained during a 1-minute proximal right coronary artery (RCA) and left coronary artery balloon occlusion at baseline before and at follow-up examination 6 weeks after distal right internal mammary artery device closure. Collateral flow index is the ratio between simultaneously recorded mean coronary occlusive pressure divided by mean aortic pressure, both subtracted by central venous pressure. Secondary study end points were fractional flow reserve during vessel patency, the quantitative intracoronary ECG ST-segment elevation, and angina pectoris during the same 1-minute coronary occlusion. Collateral flow index in the untreated RCA and left coronary artery changed from 0.071±0.082 at baseline to 0.132±0.117 ( P <0.0001) at follow-up examination and from 0.106±0.092 to 0.081±0.079 ( P =0.29), respectively. RCA fractional flow reserve increased significantly ( P =0.0029) from baseline to follow-up examination, despite deferral of coronary intervention in all patients. There was a decrease in intracoronary ECG ST-elevation during RCA occlusion from baseline to follow-up examination ( P =0.0015); it did not change in the left coronary artery. Angina pectoris during RCA occlusion tended to occur in fewer patients at follow-up versus baseline examination ( P =0.06). Permanent right internal mammary artery device closure seems to augment extracardiac ipsilateral coronary supply to the effect of reducing ischemia in the dependent myocardial region. URL: http://www.clinicaltrials.gov. Unique identifier: NCT02475408. © 2017 The Authors.

  19. Intravascular laser speckle imaging for the mechanical analysis of coronary plaques (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Hosoda, Masaki; Wang, Jing; Tsikudi, Diane; Nadkarni, Seemantini

    2016-02-01

    Acute myocardial infarction is frequently caused by the rupture of coronary plaques with severely compromised viscoelastic properties. We have developed a new optical technology termed intravascular laser speckle imaging (ILSI) that evaluates plaque viscoelastic properties, by measuring the time scale (time constant, τ) of temporally evolving laser speckle fluctuations. To enable coronary evaluation in vivo, an optical ILSI catheter has been developed that accomplishes omni-directional illumination and viewing of the entire coronary circumference without the need for mechanical rotation. Here, we describe the capability of ILSI for evaluating human coronary atherosclerosis in cadaveric hearts. ILSI was conducted in conjunction with optical coherence tomography (OCT) imaging in five human cadaveric hearts. The left coronary artery (LCA), left anterior descending (LAD), left circumflex artery (LCx), and right coronary artery (RCA) segments were resected and secured on custom-developed coronary holders to enable accurate co-registration between ILSI, OCT, and histopathology. Speckle time constants, τ, calculated from each ILSI section were compared with lipid and collagen content measured from quantitative Histopathological analysis of the corresponding Oil Red O and Picrosirius Red stained sections. Because the presence of low viscosity lipid elicits rapid speckle fluctuations, we observed an inverse correlation between τ measured by ILSI and lipid content (R= -0.64, p< 0.05). In contrast, the higher viscoelastic modulus of fibrous regions resulted in a positive correlation between τ and collagen content (R= 0.54, p< 0.05). These results demonstrate the feasibility of conducting ILSI evaluation of arterial mechanical properties using a miniaturized omni-directional catheter.

  20. Direct implantation of rapamycin-eluting stents with bioresorbable drug carrier technology utilising the Svelte coronary stent-on-a-wire: the DIRECT II study.

    PubMed

    Verheye, Stefan; Khattab, Ahmed A; Carrie, Didier; Stella, Pieter; Slagboom, Ton; Bartunek, Jozef; Onuma, Yoshinobu; Serruys, Patrick W

    2016-08-05

    Our aim was to demonstrate the safety and efficacy of the Svelte sirolimus-eluting coronary stent-on-a-wire Integrated Delivery System (IDS) with bioresorbable drug coating compared to the Resolute Integrity zotarolimus-eluting stent with durable polymer in patients with de novo coronary artery lesions. Direct stenting, particularly in conjunction with transradial intervention (TRI), has been associated with reduced bleeding complications, procedure time, radiation exposure and contrast administration compared to conventional stenting with wiring and predilatation. The low-profile Svelte IDS is designed to facilitate TRI and direct stenting, reducing the number of procedural steps, time and cost associated with coronary stenting. DIRECT II was a prospective, multicentre trial which enrolled 159 patients to establish non-inferiority of the Svelte IDS versus Resolute Integrity using a 2:1 randomisation. The primary endpoint was angiographic in-stent late lumen loss (LLL) at six months. Target vessel failure (TVF), as well as secondary clinical endpoints, will be assessed annually up to five years. At six months, in-stent LLL was 0.09±0.31 mm in the Svelte IDS group compared to 0.13±0.27 mm in the Resolute Integrity group (p<0.001 for non-inferiority). TVF at one year was similar across the Svelte IDS and Resolute Integrity groups (6.5% vs. 9.8%, respectively). DIRECT II demonstrated the non-inferiority of the Svelte IDS to Resolute Integrity with respect to in-stent LLL at six months. Clinical outcomes at one year were comparable between the two groups.

  1. Coronary responses to endothelin-1 and acetylcholine during partial coronary ischaemia and reperfusion in anaesthetized goats.

    PubMed

    Martínez, Maria Angeles; Fernández, Nuria; Monge, Luis; García-Villalón, Angel Luis; Sanz, Elena; Diéguez, Godofredo

    2002-08-01

    To examine coronary reactivity to acetylcholine and endothelin-1 (ET-1) during partial ischaemia and reperfusion, flow in the left circumflex coronary artery was measured electromagnetically, and coronary partial ischaemia was induced by stenosis of this artery in anaesthetized goats. In eight animals not treated with N(G)-nitro-l-arginine methyl ester (l-NAME), coronary stenosis reduced coronary flow by 45%, mean arterial pressure by 16% and coronary vascular conductance by 34%. During this ischaemia, coronary vasodilatation to acetylcholine (0.003-0.1 microg) and sodium nitroprusside (SNP; 1-10 microg) was markedly reduced, and coronary vasoconstriction to ET-1 (0.01-0.3 nmol) was attenuated. After 30 min of reperfusion, coronary flow, mean arterial pressure and coronary vascular conductance remained decreased, and the effects of acetylcholine, SNP and ET-1 were as in control animals. In six goats treated with N(G)-nitro-l-arginine methyl ester, coronary stenosis reduced coronary flow by 26% and coronary vascular conductance by 24%, but did not affect mean arterial pressure. During this ischaemia, coronary vasodilatation to acetylcholine and SNP was also markedly reduced, but vasoconstriction to ET-1 was unaffected. After 30 min of reperfusion, coronary flow and coronary vascular conductance remained decreased and mean arterial pressure was normal; in addition, the effects of acetylcholine were lower, those of SNP were similar and those of ET-1 were higher than in control animals. Therefore partial ischaemia reduces the coronary vasodilator reserve and blunts coronary vasoconstriction to ET-1, and reperfusion does not alter the endothelium-dependent and -independent coronary vasodilatation or vasoconstriction to ET-1.

  2. Impaired digital reactive hyperemia and the risk of restenosis after primary coronary intervention in patients with acute coronary syndrome.

    PubMed

    Yamamoto, Masaya; Hara, Hisao; Moroi, Masao; Ito, Shingo; Nakamura, Masato; Sugi, Kaoru

    2014-01-01

    Reactive hyperemia peripheral arterial tonometry (RH-PAT) can be used to noninvasively assess the vascular function with respect to the digital microcirculation. Abnormalities are associated with coronary endothelial dysfunction. We therefore investigated whether impaired digital reactive hyperemia is associated with restenosis after percutaneous coronary intervention (PCI) in patients with acute coronary syndrome (ACS). This study included 86 patients with ACS who underwent successful primary PCI of native vessels for de novo lesions. The reactive hyperemia index (RHI) was calculated using RH-PAT at three weeks and eight months after ACS. The RHI was defined as the ratio of the digital pulse volume during reactive hyperemia to that observed at baseline. Restenosis was defined as diameter stenosis of ≥ 50% in the in-segment area based on the findings of quantitative coronary angiography performed at eight months. Restenosis was detected in 17 patients (20%). There were no differences in the RHI at three weeks between the patients with and without restenosis (1.70 vs. 1.87; p=0.13); however, the RHI values at eight months were significantly attenuated in the patients with restenosis versus those without (1.75 vs. 2.12; p=0.03). A univariate logistic regression analysis showed that the eight-month RHI (<2, obtained from a receiver operating characteristic analysis) was a significant risk factor for restenosis (odds ratio: 4.23, 95% confidence interval: 1.25 to 14.28, p=0.02). Impairment of the digital hyperemic response at eight months is associated with restenosis after primary intervention in patients with ACS, suggesting the potential of RH-PAT as a noninvasive test for identifying patients with a high risk of restenosis.

  3. Systemic effects of intracoronary nitroglycerin during coronary angiography in children after heart transplantation.

    PubMed

    Lara, Diego A; Olive, Mary K; George, James F; Brown, Robert N; Carlo, Waldemar F; Colvin, Edward V; Steenwyck, Brad L; Pearce, F Bennett

    2014-02-01

    Coronary spasm during coronary angiography for vasculopathy in children can be prevented by the intracoronary administration of nitroglycerin. We reviewed the anesthesia and catheterization reports and charts for pediatric transplant recipients who underwent angiography from 2005 through 2010. Correlation analysis was used to study the relation of post-injection systolic blood pressure (SBP) to nitroglycerin dose. Forty-one angiographic evaluations were performed on 25 patients (13 male and 12 female). Mean age was 9.9 ± 3.2 years (range, 3.3-16.1 yr). The mean total dose of nitroglycerin was 2.93 ± 1.60 µg/kg (range, 1-8 µg/kg). There was a significant drop between the baseline SBP (mean, 106 ± 21.6 mmHg) and the lowest mean SBP before nitroglycerin administration (78 ± 13.2, P <0.0001, paired t test). There was no significant additional change in SBP (mean after nitroglycerin administration, 80.7 ± 13.1 mmHg; P = 0.2). There was a significant drop in lowest heart rate between baseline (109 ± 16.5 beats/min) and before nitroglycerin administration (89 ± 14.3 beats/min; P <0.0001, paired t test). There was no significant additional change in heart rate (mean heart rate after nitroglycerin, 84 ± 17.7 beats/min; P = 0.09). There were 2 interventions for SBP before nitroglycerin and 2 after nitroglycerin. One child experienced a transient ST-T-segment change during angiography after nitroglycerin. In the highest dose range, the additional decrease in SBP was 7.2 mmHg (P=0.03). Routine intracoronary nitroglycerin administration in this dose range produced no significant changes in SBP or heart rate in children.

  4. [A gender perspective analysis of perception and practices in coronary disease in women from northern México].

    PubMed

    Juárez-Herrera Y Cairo, Lucero Aída; Castro-Vásquez, María Del Carmen; Ruiz-Cantero, María Teresa

    2016-08-01

    To analyze the perception of coronary risk and health care practices in a group of Mexican women, from a gendered perspective. Mixed methods: survey of 140 women; nine in-depth interviews to women with coronary disease; eight semi-structured interviews to physicians. proportions contrast for quantitative data; and procedures of grounded theory for qualitative information. More than 50% of women don't know their coronary risk and how to reduce it. Despite having information about heart disease, vulnerable women with chest pain sought medical attendance less than non-vulnerable women (p=0.0l); and are blamed by physicians. Women consider they lack sufficient information about how to reduce the risk of coronary disease, and blame themselves when ill. There are vulnerability conditions in women that modulate a low perception of their being at risk, and the scarcity of health care practices.

  5. Redo coronary bypass grafting for congenital left main coronary atresia: a case report.

    PubMed

    Yajima, Shin; Toda, Koichi; Nishi, Hiroyuki; Yoshioka, Daisuke; Nakamura, Teruya; Miyagawa, Shigeru; Yoshikawa, Yasushi; Fukushima, Satsuki; Sawa, Yoshiki

    2017-05-15

    Congenital left main coronary atresia is an extremely rare coronary anomaly. Long-term surgical outcomes and the optimal management strategies for recurrence of ischemia remain uncertain. Herein, we present a case involving successful redo coronary artery bypass grafting for unstable angina 27 years after the initial coronary artery bypass grafting for congenital left main coronary atresia. A 33-year-old woman was referred to our department with unstable angina. At the age of 6, she had undergone coronary artery bypass grafting of the second diagonal branch using the left internal thoracic artery and the obtuse marginal branch using saphenous vein grafting for left main coronary atresia. Although a coronary angiogram showed a patent left internal thoracic artery graft to the second diagonal branch and a patent saphenous vein graft to the obtuse marginal branch, the left anterior descending artery was not being perfused by the grafts because of a disruption of blood flow to the left anterior descending artery from the left internal thoracic artery. Therefore, we performed a redo coronary artery bypass grafting using the in situ right internal thoracic artery to the first diagonal branch, which was to be connected to the left anterior descending artery, resulting in amelioration of the ischemia of the left anterior wall. The patient was discharged 10 days after the operation and has been in good health for over 3 years without recurrence of chest symptoms. Coronary revascularization using a saphenous vein and left internal thoracic artery grafts is effective in achieving an adequate blood supply to the distal coronary arteries, and this effect can last for decades. However, careful follow-up is necessary because recurrent myocardial ischemia due to the development of a coronary artery occlusion may occur in adulthood.

  6. The additional value of patient‐reported health status in predicting 1‐year mortality after invasive coronary procedures: a report from the Euro Heart Survey on Coronary Revascularisation

    PubMed Central

    Lenzen, Mattie J; Reimer, Wilma J M Scholte op; Pedersen, Susanne S; Boersma, Eric; Maier, Willibald; Widimsky, Petr; Simoons, Maarten L; Mercado, Nestor F; Wijns, William

    2007-01-01

    Objective Self‐perceived health status may be helpful in identifying patients at high risk for adverse outcomes. The Euro Heart Survey on Coronary Revascularization (EHS‐CR) provided an opportunity to explore whether impaired health status was a predictor of 1‐year mortality in patients with coronary artery disease (CAD) undergoing angiographic procedures. Methods Data from the EHS‐CR that included 5619 patients from 31 member countries of the European Society of Cardiology were used. Inclusion criteria for the current study were completion of a self‐report measure of health status, the EuroQol Questionnaire (EQ‐5D) at discharge and information on 1‐year follow‐up, resulting in a study population of 3786 patients. Results The 1‐year mortality was 3.2% (n = 120). Survivors reported fewer problems on the five dimensions of the EQ‐5D as compared with non‐survivors. A broad range of potential confounders were adjusted for, which reached a p<0.10 in the unadjusted analyses. In the adjusted analyses, problems with self‐care (OR 3.45; 95% CI 2.14 to 5.59) and a low rating (⩽60) on health status (OR 2.41; 95% CI 1.47 to 3.94) were the most powerful independent predictors of mortality, among the 22 clinical variables included in the analysis. Furthermore, patients who reported no problems on all five dimensions had significantly lower 1‐year mortality rates (OR 0.47; 95% CI 0.28 to 0.81). Conclusions This analysis shows that impaired health status is associated with a 2–3‐fold increased risk of all‐cause mortality in patients with CAD, independent of other conventional risk factors. These results highlight the importance of including patients' subjective experience of their own health status in the evaluation strategy to optimise risk stratification and management in clinical practice. PMID:16980515

  7. The SABRE Trial (Sirolimus Angioplasty Balloon for Coronary In-Stent Restenosis): Angiographic Results and 1-Year Clinical Outcomes.

    PubMed

    Verheye, Stefan; Vrolix, Mathias; Kumsars, Indulis; Erglis, Andrejs; Sondore, Dace; Agostoni, Pierfrancesco; Cornelis, Kristoff; Janssens, Luc; Maeng, Michael; Slagboom, Ton; Amoroso, Giovanni; Jensen, Lisette Okkels; Granada, Juan F; Stella, Pieter

    2017-10-23

    The aim of this first-in-human study was to assess the safety and effectiveness of the Virtue sirolimus-eluting balloon in a cohort of patients with in-stent restenosis (ISR). Angioplasty balloons coated with the cytotoxic drug paclitaxel have been widely used for ISR treatment. The Virtue angioplasty balloon (Caliber Therapeutics, New Hope, Pennsylvania) delivers sirolimus in a nanoencapsulated liquid formulation. This clinical trial is the first to examine a sirolimus-eluting balloon for ISR. In this prospective, single-arm feasibility study at 9 European centers, 50 ISR patients were treated with the Virtue balloon. Angiographic measurements at 6 months are reported, along with 12-month clinical follow-up. Procedural success in the intention-to-treat population was 100%. The primary safety endpoint was target lesion failure (TLF) (cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularization) assessed at 30 days (0%, n = 50). The primary performance endpoint was in-segment late lumen loss (LLL) at 6 months (0.31 ± 0.52 mm; n = 47). Secondary 6-month endpoints include binary restenosis (19.1%), diameter stenosis (30.3 ± 19.9%), and major adverse cardiac events (MACE) (10.2%, n = 49). In the 36-patient per-protocol population (excluding major protocol violations and previously stented ISR), LLL was 0.12 ± 0.33 mm at 6 months. Clinical outcomes at 1 year for the intention-to-treat group were 12.2% TLF and 14.3% MACE and for the per-protocol population were 2.8% TLF and 2.8% MACE. This first-in-human study showed excellent procedural success for the Virtue sirolimus-eluting angioplasty balloon, 6-month LLL rates in line with current stent-free ISR treatment options, and clinical outcomes that warrant further evaluation in dedicated randomized studies. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  8. Myocardial blood flow: Roentgen videodensitometry techniques

    NASA Technical Reports Server (NTRS)

    Smith, H. C.; Robb, R. A.; Wood, E. H.

    1975-01-01

    The current status of roentgen videodensitometric techniques that provide an objective assessment of blood flow at selected sites within the coronary circulation were described. Roentgen videodensitometry employs conventional radiopaque indicators, radiological equipment and coronary angiographic techniques. Roentgen videodensitometry techniques developed in the laboratory during the past nine years, and for the past three years were applied to analysis of angiograms in the clinical cardiac catheterization laboratory.

  9. Immunoglobulins against Tyrosine Nitrated Epitopes in Coronary Artery Disease

    PubMed Central

    Thomson, Leonor; Tenopoulou, Margarita; Lightfoot, Richard; Tsika, Epida; Parastatidis, Ioannis; Martinez, Marissa; Greco, Todd M.; Doulias, Paschalis-Thomas; Wu, Yuping; Tang, W. H. Wilson; Hazen, Stanley L.; Ischiropoulos, Harry

    2012-01-01

    Background Several lines of evidence support a pathophysiological role of immunity in atherosclerosis. Tyrosine nitrated proteins, a footprint of oxygen and nitrogen derived oxidants generated by cells of the immune system, are enriched in atheromatous lesions and in circulation of coronary artery disease (CAD) subjects. However, the consequences of possible immune reactions triggered by the presence of nitrated proteins in subjects with clinically documented atherosclerosis have not been explored. Methods and Results Specific immunoglobulins that recognize 3-nitrotyrosine epitopes were identified in human lesions, as well as in circulation of CAD subjects. The levels of circulating immunoglobulins against 3-nitrotyrosine epitopes were quantified in CAD patients (n=374) and subjects without CAD (non CAD controls, n=313). A ten-fold increase in the mean level of circulating immunoglobulins against protein-bound 3-nitrotyrosine was documented in the CAD subjects (3.75 ± 1.8 μg antibody Eq/mL plasma vs. 0.36 ± 0.8 μg antibody Eq/mL plasma), and was strongly associated with angiographic evidence of significant CAD. Conclusions The results of this cross sectional study suggest that post-translational modification of proteins via nitration within atherosclerotic plaque-laden arteries and in circulation serve as neoepitopes for elaboration of immunoglobulins, thereby providing an association between oxidant production and the activation of the immune system in CAD. PMID:23081989

  10. Pattern not volume of bleeding predicts angiographic vasospasm in nonaneurysmal subarachnoid hemorrhage.

    PubMed

    Raya, Amanda; Zipfel, Gregory J; Diringer, Michael N; Dacey, Ralph G; Derdeyn, Colin P; Rich, Keith M; Chicoine, Michael R; Dhar, Rajat

    2014-01-01

    Spontaneous idiopathic subarachnoid hemorrhage (SAH) with a perimesencephalic bleeding pattern is usually associated with a benign course, whereas a diffuse bleeding pattern has been associated with a higher risk of vasospasm and disability. We evaluated whether volume of bleeding explains this disparity. Pattern and amount of bleeding (by Hijdra and intraventricular hemorrhage scores) were assessed in 89 patients with nonaneurysmal SAH. Outcomes included angiographic vasospasm, delayed cerebral ischemia, and functional outcome at 1 year. Diffuse bleeding was associated with significantly higher Hijdra and intraventricular hemorrhage scores than perimesencephalic SAH, P≤0.003. Angiographic vasospasm was more likely in diffuse versus perimesencephalic SAH (45% versus 27%; odds ratio, 2.9; P=0.08), but adjustment for greater blood burden only partially attenuated this trend (adjusted odds ratio, 2.2; 95% confidence interval, 0.69-7.2; P=0.18); delayed cerebral ischemia was only seen in those with diffuse bleeding. Patients with diffuse bleeding were less likely to be discharged home (68% versus 90%; P=0.01) and tended to have more residual disability (modified Rankin scale, 3-6; 20% versus 6%; P=0.18). Nonaneurysmal SAH can still result in vasospasm and residual disability, especially in those with diffuse bleeding. This disparity is only partially accounted for by greater cisternal or intraventricular blood, suggesting that the mechanism and distribution of bleeding may be as important as the amount of hemorrhage in patients with idiopathic SAH.

  11. Body mass index and myocardium at risk in patients with acute coronary syndrome.

    PubMed

    Arrebola-Moreno, A L; Marfil-Alvarez, R; Catena, A; García-Retamero, R; Arrebola, J P; Melgares-Moreno, R; Ramirez-Hernández, J A; Kaski, J C

    2014-04-01

    Whilst traditional studies have shown that obese individuals are at a higher risk of cardiovascular events compared to lean subjects, recent studies in patients with acute myocardial infarction (AMI) have suggested that obesity may exert protective effects (the "obesity paradox"). We sought to assess the relationship between body mass index (BMI) and the BARI score (BARIsc), a validated tool used to assess myocardium at risk, in patients with acute coronary syndrome. Participants were 116 consecutive patients (mean age, 60.6 years; 97 men) with AMI (68 ST elevated myocardial infarction, STEMI; 48 non-ST elevated myocardial infarction, NSTEMI). Demographics, BMI, risk factors, biochemistry data, left ventricular function, angiographic data and the BARIsc were assessed in every patient. Multiple linear regression analyses showed that BMI significantly correlated with BARIsc; β=.23, p<0.02. This was found only in the overweight/obese patients, β=.27, p<0.01, but not in patients with normal BMIs, β=0.08, p=0.71. An increased body weight is associated with an increased area of myocardium at risk in patients with ACS. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  12. [Experimental evaluation of the role of the coronary sinus pressure in the regulation of coronary return volume via the coronary sinus. Surgical considerations in atrio-pulmonary diversion procedures].

    PubMed

    Fantidis, P; Fernández Ruiz, M A; Madero Jarabo, R; Moreno Granados, F; Cordovilla Zurdo, G; Sanz Galeote, E

    1990-11-01

    In order to find out the validity of the vascular waterfall mechanism in coronary venous circulation, the role of coronary sinus pressure in the regulation of coronary return volume via the coronary sinus is studied in healthy animals. An experimental model of pressure regulation in the coronary sinus was prepared, and aortic pressure, EKG and the cardiac output (measured by thermodilution) were recorded. The return volume via the coronary sinus was measured at coronary sinus pressure of 10 or less, 15, 20, and 25 mmHg or more, for a total of 36 determinations. Increased coronary sinus pressure did not produce significant changes in aortic pressure, heart rate, cardiac index or coronary return volume via coronary sinus. When coronary sinus pressure was 25 mmHg or more, there was a significant decline in the average of coronary return volume via coronary sinus. Nevertheless, stepwise variant regression showed that the coronary sinus pressure per se does not condition the volume of coronary return via the coronary sinus. Our results suggest that in the healthy animals, the vascular waterfall mechanism in coronary venous circulation is not valid. Our results suggest that in the correction of congenital cardiac malformations using atriopulmonary anastomosis procedures, employing techniques that ensure coronary sinus drainage into the left atrium, in order to avoid the hemodynamic repercussions attributable to the vascular waterfall mechanism, is not justified.

  13. Comparison between MDCT and Grayscale IVUS in a Quantitative Analysis of Coronary Lumen in Segments with or without Atherosclerotic Plaques

    PubMed Central

    Falcão, João L. A. A.; Falcão, Breno A. A.; Gurudevan, Swaminatha V.; Campos, Carlos M.; Silva, Expedito R.; Kalil-Filho, Roberto; Rochitte, Carlos E.; Shiozaki, Afonso A.; Coelho-Filho, Otavio R.; Lemos, Pedro A.

    2015-01-01

    Background The diagnostic accuracy of 64-slice MDCT in comparison with IVUS has been poorly described and is mainly restricted to reports analyzing segments with documented atherosclerotic plaques. Objectives We compared 64-slice multidetector computed tomography (MDCT) with gray scale intravascular ultrasound (IVUS) for the evaluation of coronary lumen dimensions in the context of a comprehensive analysis, including segments with absent or mild disease. Methods The 64-slice MDCT was performed within 72 h before the IVUS imaging, which was obtained for at least one coronary, regardless of the presence of luminal stenosis at angiography. A total of 21 patients were included, with 70 imaged vessels (total length 114.6 ± 38.3 mm per patient). A coronary plaque was diagnosed in segments with plaque burden > 40%. Results At patient, vessel, and segment levels, average lumen area, minimal lumen area, and minimal lumen diameter were highly correlated between IVUS and 64-slice MDCT (p < 0.01). However, 64-slice MDCT tended to underestimate the lumen size with a relatively wide dispersion of the differences. The comparison between 64-slice MDCT and IVUS lumen measurements was not substantially affected by the presence or absence of an underlying plaque. In addition, 64-slice MDCT showed good global accuracy for the detection of IVUS parameters associated with flow-limiting lesions. Conclusions In a comprehensive, multi-territory, and whole-artery analysis, the assessment of coronary lumen by 64-slice MDCT compared with coronary IVUS showed a good overall diagnostic ability, regardless of the presence or absence of underlying atherosclerotic plaques. PMID:25993595

  14. Prevalence, Predictors, and Clinical Presentation of a Calcified Nodule as Assessed by Optical Coherence Tomography.

    PubMed

    Lee, Tetsumin; Mintz, Gary S; Matsumura, Mitsuaki; Zhang, Wenbin; Cao, Yang; Usui, Eisuke; Kanaji, Yoshihisa; Murai, Tadashi; Yonetsu, Taishi; Kakuta, Tsunekazu; Maehara, Akiko

    2017-08-01

    This study sought to determine the anatomic characteristics and clinical presentation associated with a calcified nodule (CN) as assessed by optical coherence tomography. CN is an unusual but demonstrable cause of acute coronary syndromes (ACS). We studied 889 de novo culprit lesions in 889 patients (48% ACS) who underwent optical coherence tomography before intervention. CN was defined as an eruptive accumulation of nodular calcification (small fractured calcifications). Using quantitative coronary angiography, the change in the angle of the lesion between diastole and systole was measured (angiographic Δ angle). CN was seen in 4.2% of all lesions and was located more frequently in the ostial or mid right coronary artery. Hemodialysis (odds ratio: 4.0; 95% confidence interval: 1.1 to 13.4; p = 0.04), in-lesion angiographic Δ angle (odds ratio: 1.09; 95% confidence interval: 1.05 to 1.14; p < 0.001), and maximum calcium arc by optical coherence tomography (odds ratio: 1.02; 95% confidence interval: 1.01 to 1.02; p < 0.001) were significantly associated with the presence of a CN in the multivariable model. When we compared CNs in patients with ACS versus stable angina presentation, there was a smaller minimum lumen area (1.04 mm 2 [first quartile, third quartile: 0.69, 1.26] vs. 1.61 [first quartile, third quartile: 1.03, 2.06] mm 2 ; p = 0.02) accompanied by more thrombus (82.4% vs. 20.0%; p < 0.001) in CN lesions with ACS presentation. In lesions with severe calcification (maximum calcium arc >180°), 30% of ACS culprit lesions contained a CN, and the presence of a CN was associated with ACS presentation independent of other vulnerable plaque morphologies. The presence of a CN was associated with severe calcification and larger hinge movement of the coronary artery (especially ostial and mid right coronary artery). One-third of the underlying plaque morphology of severely calcified culprit lesions in patients with ACS was caused by a CN. Copyright

  15. The human coronary vasodilatory response to acute mental stress is mediated by neuronal nitric oxide synthase.

    PubMed

    Khan, Sitara G; Melikian, Narbeh; Shabeeh, Husain; Cabaco, Ana R; Martin, Katherine; Khan, Faisal; O'Gallagher, Kevin; Chowienczyk, Philip J; Shah, Ajay M

    2017-09-01

    Mental stress-induced ischemia approximately doubles the risk of cardiac events in patients with coronary artery disease, yet the mechanisms underlying changes in coronary blood flow in response to mental stress are poorly characterized. Neuronal nitric oxide synthase (nNOS) regulates basal coronary blood flow in healthy humans and mediates mental stress-induced vasodilation in the forearm. However, its possible role in mental stress-induced increases in coronary blood flow is unknown. We studied 11 patients (6 men and 5 women, mean age: 58 ± 14 yr) undergoing elective diagnostic cardiac catheterization and assessed the vasodilator response to mental stress elicited by the Stroop color-word test. Intracoronary substance P (20 pmol/min) and isosorbide dinitrate (1 mg) were used to assess endothelium-dependent and -independent vasodilation, respectively. Coronary blood flow was estimated using intracoronary Doppler recordings and quantitative coronary angiography to measure coronary artery diameter. Mental stress increased coronary flow by 34 ± 7.0% over the preceding baseline during saline infusion ( P < 0.01), and this was reduced to 26 ± 7.0% in the presence of the selective nNOS inhibitor S -methyl-l-thiocitrulline (0.625 µmol/min, P < 0.001). Mental stress increased coronary artery diameter by 6.9 ± 3.7% ( P = 0.02) and 0.5 ± 2.8% ( P = 0.51) in the presence of S -methyl-l-thiocitrulline. The response to substance P did not predict the response to mental stress ( r 2 = -0.22, P = 0.83). nNOS mediates the human coronary vasodilator response to mental stress, predominantly through actions at the level of coronary resistance vessels. NEW & NOTEWORTHY Acute mental stress induces vasodilation of the coronary microvasculature. Here, we show that this response involves neuronal nitric oxide synthase in the human coronary circulation.Listen to this article's corresponding podcast at http://ajpheart.podbean.com/e/nnos-and-coronary

  16. The human coronary vasodilatory response to acute mental stress is mediated by neuronal nitric oxide synthase

    PubMed Central

    Khan, Sitara G.; Melikian, Narbeh; Shabeeh, Husain; Cabaco, Ana R.; Martin, Katherine; Khan, Faisal; O’Gallagher, Kevin; Chowienczyk, Philip J.

    2017-01-01

    Mental stress-induced ischemia approximately doubles the risk of cardiac events in patients with coronary artery disease, yet the mechanisms underlying changes in coronary blood flow in response to mental stress are poorly characterized. Neuronal nitric oxide synthase (nNOS) regulates basal coronary blood flow in healthy humans and mediates mental stress-induced vasodilation in the forearm. However, its possible role in mental stress-induced increases in coronary blood flow is unknown. We studied 11 patients (6 men and 5 women, mean age: 58 ± 14 yr) undergoing elective diagnostic cardiac catheterization and assessed the vasodilator response to mental stress elicited by the Stroop color-word test. Intracoronary substance P (20 pmol/min) and isosorbide dinitrate (1 mg) were used to assess endothelium-dependent and -independent vasodilation, respectively. Coronary blood flow was estimated using intracoronary Doppler recordings and quantitative coronary angiography to measure coronary artery diameter. Mental stress increased coronary flow by 34 ± 7.0% over the preceding baseline during saline infusion (P < 0.01), and this was reduced to 26 ± 7.0% in the presence of the selective nNOS inhibitor S-methyl-l-thiocitrulline (0.625 µmol/min, P < 0.001). Mental stress increased coronary artery diameter by 6.9 ± 3.7% (P = 0.02) and 0.5 ± 2.8% (P = 0.51) in the presence of S-methyl-l-thiocitrulline. The response to substance P did not predict the response to mental stress (r2 = −0.22, P = 0.83). nNOS mediates the human coronary vasodilator response to mental stress, predominantly through actions at the level of coronary resistance vessels. NEW & NOTEWORTHY Acute mental stress induces vasodilation of the coronary microvasculature. Here, we show that this response involves neuronal nitric oxide synthase in the human coronary circulation. Listen to this article’s corresponding podcast at http://ajpheart.podbean.com/e/nnos-and-coronary-flow-during-mental-stress/. PMID

  17. The surgical significance of the atrial branches of the coronary arteries.

    PubMed

    Busquet, J; Fontan, F; Anderson, R H; Ho, S Y; Davies, M J

    1984-08-01

    The great number of open heart operations now performed via the right atrium, makes knowledge of the arrangement of the atrial arteries, particularly the sinus node artery, every important for the surgeon. Although studied by anatomists, little attention has been paid to the surgical significance of these arteries. We have therefore examined the distribution of the right atrial arteries and the course of the sinus node artery in 50 normal adult hearts by classic dissection following, in 30 cases, postmortem angiographic studies. Two major arteries of the right atrium were found to be nearly constant. The anterior artery was present in 96% of the cases and supplied the sinus node artery in 32 cases. Of most surgical significance was the lateral artery found in 90% of the cases. This lateral artery was the principal artery to the free atrial wall and in one case gave rise to the sinus node artery. The well-established preponderance of origin of the sinus node artery from the right coronary system (66%) as opposed to the left (30%) was confirmed. Infrequently, a double supply (4%) was seen. Variability was found in the course of the nodal artery relative to the cavoatrial junction - precaval (58%), retrocaval (36%) or encircling (6%).

  18. First-in-man study of simvastatin-eluting stent in de novo coronary lesions: the SIMVASTENT study.

    PubMed

    Zago, Alexandre C; Matte, Bruno S; Reginato, Luciana; Iturry-Yamamoto, Germán; Krepsky, Ana; Bergoli, Luiz Carlos C; Balvedi, Julise; Raudales, José C; Saadi, Eduardo K; Zago, Alcides J

    2012-01-01

    Statins have anti-inflammatory and antiproliferative properties irrespective of their cholesterol-lowering effects. The aim of the present study was to evaluate a simvastatin-eluting stent (SimvES) in the treatment of de novo coronary lesions. Forty-two patients with de novo coronary artery lesions were assigned to SimvES, bare-metal stent (BMS) or everolimus-eluting stent (EES) implantation followed by intravascular ultrasound (IVUS) for neointimal quantitative analysis. Six months later, quantitative coronary angiography (QCA) and IVUS were repeated. QCA showed no binary restenosis, a mean in-stent late loss of 1.05 ± 0.25 mm (BMS, 1.12 ± 0.48 mm; EES, 0.20 ± 0.16 mm) and a diameter stenosis of 33.5 ± 7.1% (BMS, 35.5 ± 15.30%; EES, 7.2 ± 3.12%). Control IVUS showed a mean in-stent obstruction of 18.3 ± 9.4% (BMS, 32.8 ± 19.1%; EES, 9.8 ± 2.4%) and a neointimal volume index of 1.58 ± 0.75 mm(3)/mm (BMS, 2.93 ± 1.76 mm(3)/mm; EES, 0.80 ± 0.16 mm(3)/mm). Thrombus, late incomplete apposition and major adverse cardiac events were not observed. In this sample of patients with de novo coronary lesions, the use of a SimvES was not related to major adverse cardiac events, but it was associated with a higher level of neointimal proliferation than expected.

  19. Intensive lifestyle changes for reversal of coronary heart disease.

    PubMed

    Ornish, D; Scherwitz, L W; Billings, J H; Brown, S E; Gould, K L; Merritt, T A; Sparler, S; Armstrong, W T; Ports, T A; Kirkeeide, R L; Hogeboom, C; Brand, R J

    1998-12-16

    The Lifestyle Heart Trial demonstrated that intensive lifestyle changes may lead to regression of coronary atherosclerosis after 1 year. To determine the feasibility of patients to sustain intensive lifestyle changes for a total of 5 years and the effects of these lifestyle changes (without lipid-lowering drugs) on coronary heart disease. Randomized controlled trial conducted from 1986 to 1992 using a randomized invitational design. Forty-eight patients with moderate to severe coronary heart disease were randomized to an intensive lifestyle change group or to a usual-care control group, and 35 completed the 5-year follow-up quantitative coronary arteriography. Two tertiary care university medical centers. Intensive lifestyle changes (10% fat whole foods vegetarian diet, aerobic exercise, stress management training, smoking cessation, group psychosocial support) for 5 years. Adherence to intensive lifestyle changes, changes in coronary artery percent diameter stenosis, and cardiac events. Experimental group patients (20 [71%] of 28 patients completed 5-year follow-up) made and maintained comprehensive lifestyle changes for 5 years, whereas control group patients (15 [75%] of 20 patients completed 5-year follow-up) made more moderate changes. In the experimental group, the average percent diameter stenosis at baseline decreased 1.75 absolute percentage points after 1 year (a 4.5% relative improvement) and by 3.1 absolute percentage points after 5 years (a 7.9% relative improvement). In contrast, the average percent diameter stenosis in the control group increased by 2.3 percentage points after 1 year (a 5.4% relative worsening) and by 11.8 percentage points after 5 years (a 27.7% relative worsening) (P=.001 between groups. Twenty-five cardiac events occurred in 28 experimental group patients vs 45 events in 20 control group patients during the 5-year follow-up (risk ratio for any event for the control group, 2.47 [95% confidence interval, 1.48-4.20]). More regression

  20. Antithrombotic therapy for atrial fibrillation and coronary artery disease in older patients

    PubMed Central

    Hess, Connie N.; Broderick, Samuel; Piccini, Jonathan P.; Alexander, Karen P.; Newby, L. Kristin; Shaw, Linda K.; Mahaffey, Kenneth W.; Alexander, John H.; Peterson, Eric D.; Granger, Christopher B.; Lopes, Renato D.

    2013-01-01

    Background Older patients with atrial fibrillation (AF) and coronary artery disease (CAD) face high risk of stroke and bleeding with antithrombotic therapy. Balancing safe and effective use of aspirin, clopidogrel, and warfarin in this population is important. Methods From the Duke Databank for Cardiovascular Disease, we identified patients with AF ≥65 years old with angiographically confirmed CAD from 2000 to 2010. Antithrombotic use was described across age and Congestive heart failure, Hypertension, Age >75 years, Diabetes, prior Stroke/transient ischemic attack (CHADS2) stroke risk and Anticoagulation and Risk Factors in Atrial Fibrillation (ATRIA) bleeding scores. Death and the composite of death, myocardial infarction, and stroke by antithrombotic strategy were reported. Results Of 2,122 patients ≥65 years old with AF and CAD, 477 (22.5%) were ≥80 years old; 1,133 (53.4%) had acute coronary syndromes. Overall rates of aspirin, clopidogrel, and warfarin use were 83.4%, 34.6%, and 38.9%, respectively. Compared with patients 65 to 79 years old, more patients ≥80 years old were at high stroke risk (CHADS2 ≥2, 84.7% vs 57.8%) and high bleeding risk (ATRIA 5-10, 55.8% vs 23.3%). Warfarin use in both age groups increased with higher CHADS2 scores and decreased with higher ATRIA scores. Of patients ≥80 years old with CHADS2 ≥2, 150 (38.2%) received warfarin. Antithrombotic strategy was not associated with improved 1-year adjusted outcomes. Conclusions Among older patients with AF and CAD, overall warfarin use was low. Patients ≥80 years old at highest stroke risk received warfarin in similar proportions to the overall cohort. Further investigation into optimizing antithrombotic strategies in this population is warranted. PMID:23067921