Sample records for quantitative fit-testing protocols

  1. Comparison of two quantitative fit-test methods using N95 filtering facepiece respirators.

    PubMed

    Sietsema, Margaret; Brosseau, Lisa M

    2016-08-01

    Current regulations require annual fit testing before an employee can wear a respirator during work activities. The goal of this research is to determine whether respirator fit measured with two TSI Portacount instruments simultaneously sampling ambient particle concentrations inside and outside of the respirator facepiece is similar to fit measured during an ambient aerosol condensation nuclei counter quantitative fit test. Sixteen subjects (ten female; six male) were recruited for a range of facial sizes. Each subject donned an N95 filtering facepiece respirator, completed two fit tests in random order (ambient aerosol condensation nuclei counter quantitative fit test and two-instrument real-time fit test) without removing or adjusting the respirator between tests. Fit tests were compared using Spearman's rank correlation coefficients. The real-time two-instrument method fit factors were similar to those measured with the single-instrument quantitative fit test. The first four exercises were highly correlated (r > 0.7) between the two protocols. Respirator fit was altered during the talking or grimace exercise, both of which involve facial movements that could dislodge the facepiece. Our analyses suggest that the new real-time two-instrument methodology can be used in future studies to evaluate fit before and during work activities.

  2. Effect of test exercises and mask donning on measured respirator fit.

    PubMed

    Crutchfield, C D; Fairbank, E O; Greenstein, S L

    1999-12-01

    Quantitative respirator fit test protocols are typically defined by a series of fit test exercises. A rationale for the protocols that have been developed is generally not available. There also is little information available that describes the effect or effectiveness of the fit test exercises currently specified in respiratory protection standards. This study was designed to assess the relative impact of fit test exercises and mask donning on respirator fit as measured by a controlled negative pressure and an ambient aerosol fit test system. Multiple donnings of two different sizes of identical respirator models by each of 14 test subjects showed that donning affects respirator fit to a greater degree than fit test exercises. Currently specified fit test protocols emphasize test exercises, and the determination of fit is based on a single mask donning. A rationale for a modified fit test protocol based on fewer, more targeted test exercises and multiple mask donnings is presented. The modified protocol identified inadequately fitting respirators as effectively as the currently specified Occupational Safety and Health Administration (OSHA) quantitative fit test protocol. The controlled negative pressure system measured significantly (p < 0.0001) more respirator leakage than the ambient aerosol fit test system. The bend over fit test exercise was found to be predictive of poor respirator fit by both fit test systems. For the better fitting respirators, only the talking exercise generated aerosol fit factors that were significantly lower (p < 0.0001) than corresponding donning fit factors.

  3. The usefulness and reliability of fitness testing protocols for ice hockey players: a literature review.

    PubMed

    Nightingale, Steven C; Miller, Stuart; Turner, Anthony

    2013-06-01

    Ice hockey, like most sports, uses fitness testing to assess athletes. This study reviews the current commonly used fitness testing protocols for ice hockey players, discussing their predictive values and reliability. It also discusses a range of less commonly used measures and limitations in current testing protocols. The article concludes with a proposed testing program suitable for ice hockey players.

  4. Evaluation of a large-scale quantitative respirator-fit testing program for healthcare workers: survey results.

    PubMed

    Wilkinson, Irene J; Pisaniello, Dino; Ahmad, Junaid; Edwards, Suzanne

    2010-09-01

    To present the evaluation of a large-scale quantitative respirator-fit testing program. Concurrent questionnaire survey of fit testers and test subjects. Ambulatory care, home nursing care, and acute care hospitals across South Australia. Quantitative facial-fit testing was performed with TSI PortaCount instruments for healthcare workers (HCWs) who wore 5 different models of a disposable P2 (N95-equivalent) respirator. The questionnaire included questions about the HCW's age, sex, race, occupational category, main area of work, smoking status, facial characteristics, prior training and experience in use of respiratory masks, and number of attempts to obtain a respirator fit. A total of 6,160 HCWs were successfully fitted during the period from January through July 2007. Of the 4,472 HCWs who responded to the questionnaire and were successfully fitted, 3,707 (82.9%) were successfully fitted with the first tested respirator, 551 (12.3%) required testing with a second model, and 214 (4.8%) required 3 or more tests. We noted an increased pass rate on the first attempt over time. Asians (excluding those from South and Central Asia) had the highest failure rate (16.3% [45 of 276 Asian HCWs were unsuccessfully fitted]), and whites had the lowest (9.8% [426 of 4,338 white HCWs]). Race was highly correlated with facial shape. Among occupational groups, doctors had the highest failure rate (13.4% [81 of 604 doctors]), but they also had the highest proportion of Asians. Prior education and/or training in respirator use were not associated with a higher pass rate. Certain facial characteristics were associated with higher or lower pass rates with regard to fit testing, and fit testers were able to select a suitable respirator on the basis of a visual assessment in the majority of cases. For the fit tester, training and experience were important factors; however, for the HCW being fitted, prior experience in respirator use was not an important factor.

  5. Respiratory protection against Mycobacterium tuberculosis: quantitative fit test outcomes for five type N95 filtering-facepiece respirators.

    PubMed

    Lee, Kiyoung; Slavcev, Andrea; Nicas, Mark

    2004-01-01

    In preparing to fit test a large workforce, a respirator program manager needs to initially choose respirators that will fit the greatest proportion of employees and achieve the best fits. This article discusses our strategy in selecting respirators from an initial array of seven NIOSH-certified Type N95 filtering-facepiece devices for a respiratory protection program against Mycobacterium tuberculosis (M. tb) aerosol. The seven respirators were screened based on manufacturer-provided fit test data, comfort, and cost. From these 7 devices, 5 were chosen for quantitative fit testing on 40 subjects who were a convenience sample from a cohort of approximately 30,000 workers scheduled to undergo fit testing. Across the five brands, medium/regular-size respirators fit from 8% to 95% of the subjects; providing another size of the same brand improved the pass rates slightly. Gender was not found to significantly affect fit test pass rates for any respirator brand. Among test panel members, an Aearo Corporation respirator (TC 84A-2630) and a 3M Company respirator (TC 84A-0006) provided the highest overall pass rates of 98% and 90%, respectively. We selected these two brands for fit testing in the larger worker cohort. To date, these two respirators have provided overall pass rates of 98% (1793/1830) and 88% (50/57), respectively, which are similar to the test panel results. Among 1850 individuals who have been fit tested, 1843 (99.6%) have been successfully fitted with one or the other brand. In a separate analysis, we used the test panel pass rates to estimate the reduction in M. tb infection risk afforded by the medium/regular-size of five filtering-facepiece respirators. We posed a low-exposure versus a high-exposure scenario for health care workers and assumed that respirators could be assigned without conducting fit testing, as proposed by many hospital infection control practitioners. Among those who would pass versus fail the fit test, we assumed an average

  6. 75 FR 4323 - Additional Quantitative Fit-testing Protocols for the Respiratory Protection Standard

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-27

    ... respirators (500 and 1000 for protocols 1 and 2, respectively). However, OSHA could not evaluate the results... the values of these descriptive statistics for revised PortaCount[supreg] QNFT protocols 1 (at RFFs of 100 and 500) and 2 (at RFFs of 200 and 1000). Table 2--Descriptive Statistics for RFFs of 100 and 200...

  7. Automated Chemical Warfare Respirator Quantitative Fit Test Instrument

    DTIC Science & Technology

    1985-04-01

    i requisite to assessment of the level of protection provided by the respirator. Quantitative measurement of the variability of fit of the face- plec ...ACQUISITION SYSTEM CORN OIL FILlE RESERVOIR -~ HEATER CONCENTRATIOA ZAONVU~C RB EAHG1FECO PHOTOMETER- STA RT CIL RESERVOIR BOTTGM TEMPERATURE SWITCH...30 .........-.-.-... % L4* . 3.3.4 HP 3497A Control and Data Acquisition Unit lI, "%a.infraoc" i.; a box with five slots for plug-in modules pll u; a

  8. Comparison of three commercially available fit-test methods.

    PubMed

    Janssen, Larry L; Luinenburg, D Michael; Mullins, Haskell E; Nelson, Thomas J

    2002-01-01

    American National Standards Institute (ANSI) standard Z88.10, Respirator Fit Testing Methods, includes criteria to evaluate new fit-tests. The standard allows generated aerosol, particle counting, or controlled negative pressure quantitative fit-tests to be used as the reference method to determine acceptability of a new test. This study examined (1) comparability of three Occupational Safety and Health Administration-accepted fit-test methods, all of which were validated using generated aerosol as the reference method; and (2) the effect of the reference method on the apparent performance of a fit-test method under evaluation. Sequential fit-tests were performed using the controlled negative pressure and particle counting quantitative fit-tests and the bitter aerosol qualitative fit-test. Of 75 fit-tests conducted with each method, the controlled negative pressure method identified 24 failures; bitter aerosol identified 22 failures; and the particle counting method identified 15 failures. The sensitivity of each method, that is, agreement with the reference method in identifying unacceptable fits, was calculated using each of the other two methods as the reference. None of the test methods met the ANSI sensitivity criterion of 0.95 or greater when compared with either of the other two methods. These results demonstrate that (1) the apparent performance of any fit-test depends on the reference method used, and (2) the fit-tests evaluated use different criteria to identify inadequately fitting respirators. Although "acceptable fit" cannot be defined in absolute terms at this time, the ability of existing fit-test methods to reject poor fits can be inferred from workplace protection factor studies.

  9. The Viability of Hearing Protection Device Fit-Testing at Navy and Marine Corps Accession Points

    PubMed Central

    Federman, Jeremy; Duhon, Christon

    2016-01-01

    Introduction: The viability of hearing protection device (HPD) verification (i.e., fit-testing) on a large scale was investigated to address this gap in a military accession environment. Materials and Methods: Personal Attenuation Ratings (PARs) following self-fitted (SELF-Fit) HPDs were acquired from 320 US Marine Corps training recruits (87.5% male, 12.5% female) across four test protocols (1-, 3-, 5-, and 7- frequency). SELF-Fit failures received follow-up to assess potential causes. Follow-up PARs were acquired (Experimenter fit [EXP-Fit], followed by Subject re-fit [SUB Re-Fit]). EXP-Fit was intended to provide a perception (dubbed “ear canal muscle memory”) of what a correctly fitted HPD should feel like. SUB Re-Fit was completed following EXP-Fit to determine whether a training recruit could duplicate EXP-Fit on her/his own without assistance. Results: A one-way analysis of variance (ANOVA) (N=320) showed that SELF-Fit means differed significantly between protocols (P < 0.001). Post-hoc analyses showed that the 1-freq SELF-Fit mean was significantly lower than all other protocols (P < 0.03) by 5.6 dB or more. No difference was found between the multi-frequency protocols. For recruits who were followed up with EXP-Fit (n=79), across all protocols, a significant (P < 0.001) mean improvement of 25.68 dB (10.99) was found, but PARs did not differ (P = 0.99) between EXP-Fit protocols. For recruits in the 3-freq and 5-freq protocol groups who experienced all three PAR test methods (n=33), PAR methods differed (P < 0.001) but no method by protocol interaction was found (P = 0.46). Post hoc tests showed that both EXP-Fit and SUB Re-Fit had significantly better attenuation than SELF-Fit (P < 0.001), but no difference was found between EXPFit and SUB Re-Fit (P = 0.59). For SELF-Fit, the 1-freq protocol resulted in a 35% pass rate, whereas the 3-, 5-, and 7-freq protocols resulted in >60% pass rates. Results showed that once recruits experienced how HPDs should

  10. Development of a dynamic quality assurance testing protocol for multisite clinical trial DCE-CT accreditation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Driscoll, B.; Keller, H.; Jaffray, D.

    2013-08-15

    Purpose: Credentialing can have an impact on whether or not a clinical trial produces useful quality data that is comparable between various institutions and scanners. With the recent increase of dynamic contrast enhanced-computed tomography (DCE-CT) usage as a companion biomarker in clinical trials, effective quality assurance, and control methods are required to ensure there is minimal deviation in the results between different scanners and protocols at various institutions. This paper attempts to address this problem by utilizing a dynamic flow imaging phantom to develop and evaluate a DCE-CT quality assurance (QA) protocol.Methods: A previously designed flow phantom, capable of producingmore » predictable and reproducible time concentration curves from contrast injection was fully validated and then utilized to design a DCE-CT QA protocol. The QA protocol involved a set of quantitative metrics including injected and total mass error, as well as goodness of fit comparison to the known truth concentration curves. An additional region of interest (ROI) sensitivity analysis was also developed to provide additional details on intrascanner variability and determine appropriate ROI sizes for quantitative analysis. Both the QA protocol and ROI sensitivity analysis were utilized to test variations in DCE-CT results using different imaging parameters (tube voltage and current) as well as alternate reconstruction methods and imaging techniques. The developed QA protocol and ROI sensitivity analysis was then applied at three institutions that were part of clinical trial involving DCE-CT and results were compared.Results: The inherent specificity of robustness of the phantom was determined through calculation of the total intraday variability and determined to be less than 2.2 ± 1.1% (total calculated output contrast mass error) with a goodness of fit (R{sup 2}) of greater than 0.99 ± 0.0035 (n= 10). The DCE-CT QA protocol was capable of detecting significant deviations

  11. Effect of Pregnancy Upon Facial Anthropometrics and Respirator Fit Testing.

    PubMed

    Roberge, Raymond J; Kim, Jung-Hyun; Palmiero, Andrew; Powell, Jeffrey B

    2015-01-01

    Workers required to wear respirators must undergo additional respirator fit testing if a significant change in body weight occurs. Approximately 10% of working women of reproductive age will be pregnant and experience a significant change in weight, yet the effect of pregnancy-associated weight gain on respirator fit is unknown. Cephalo-facial anthropometric measurements and quantitative fit testing of N95 filtering facepiece respirators (N95 FFR) of 15 pregnant women and 15 matched, non-pregnant women were undertaken for comparisons between the groups. There were no significant differences between pregnant and non-pregnant women with respect to cephalo-facial anthropometric measurements or N95 FFR quantitative fit tests. Healthy pregnant workers, who adhere to the recommended weight gain limits of pregnancy, are unlikely to experience an increase in cephalo-facial dimensions that would mandate additional N95 FFR fit testing above that which is normally required on an annual basis.

  12. Recommended test methods and pass/fail criteria for a respirator fit capability test of half-mask air-purifying respirators

    PubMed Central

    Zhuang, Ziqing; Bergman, Michael; Lei, Zhipeng; Niezgoda, George; Shaffer, Ronald

    2017-01-01

    This study assessed key test parameters and pass/fail criteria options for developing a respirator fit capability (RFC) test for half-mask air-purifying particulate respirators. Using a 25-subject test panel, benchmark RFC data were collected for 101 National Institute for Occupational Safety and Health-certified respirator models. These models were further grouped into 61 one-, two-, or three-size families. Fit testing was done using a PortaCount® Plus with N95-Companion accessory and an Occupational Safety and Health Administration-accepted quantitative fit test protocol. Three repeated tests (donnings) per subject/respirator model combination were performed. The panel passing rate (PPR) (number or percentage of the 25-subject panel achieving acceptable fit) was determined for each model using five different alternative criteria for determining acceptable fit. When the 101 models are evaluated individually (i.e., not grouped by families), the percentages of models capable of fitting >75% (19/25 subjects) of the panel were 29% and 32% for subjects achieving a fit factor ≥100 for at least one of the first two donnings and at least one of three donnings, respectively. When the models are evaluated grouped into families and using >75% of panel subjects achieving a fit factor ≥100 for at least one of two donnings as the PPR pass/fail criterion, 48% of all models can pass. When >50% (13/25 subjects) of panel subjects was the PPR criterion, the percentage of passing models increased to 70%. Testing respirators grouped into families and evaluating the first two donnings for each of two respirator sizes provided the best balance between meeting end user expectations and creating a performance bar for manufacturers. Specifying the test criterion for a subject obtaining acceptable fit as achieving a fit factor ≥100 on at least one out of the two donnings is reasonable because a majority of existing respirator families can achieve an PPR of >50% using this criterion

  13. Recommended test methods and pass/fail criteria for a respirator fit capability test of half-mask air-purifying respirators.

    PubMed

    Zhuang, Ziqing; Bergman, Michael; Lei, Zhipeng; Niezgoda, George; Shaffer, Ronald

    2017-06-01

    This study assessed key test parameters and pass/fail criteria options for developing a respirator fit capability (RFC) test for half-mask air-purifying particulate respirators. Using a 25-subject test panel, benchmark RFC data were collected for 101 National Institute for Occupational Safety and Health-certified respirator models. These models were further grouped into 61 one-, two-, or three-size families. Fit testing was done using a PortaCount® Plus with N95-Companion accessory and an Occupational Safety and Health Administration-accepted quantitative fit test protocol. Three repeated tests (donnings) per subject/respirator model combination were performed. The panel passing rate (PPR) (number or percentage of the 25-subject panel achieving acceptable fit) was determined for each model using five different alternative criteria for determining acceptable fit. When the 101 models are evaluated individually (i.e., not grouped by families), the percentages of models capable of fitting >75% (19/25 subjects) of the panel were 29% and 32% for subjects achieving a fit factor ≥100 for at least one of the first two donnings and at least one of three donnings, respectively. When the models are evaluated grouped into families and using >75% of panel subjects achieving a fit factor ≥100 for at least one of two donnings as the PPR pass/fail criterion, 48% of all models can pass. When >50% (13/25 subjects) of panel subjects was the PPR criterion, the percentage of passing models increased to 70%. Testing respirators grouped into families and evaluating the first two donnings for each of two respirator sizes provided the best balance between meeting end user expectations and creating a performance bar for manufacturers. Specifying the test criterion for a subject obtaining acceptable fit as achieving a fit factor ≥100 on at least one out of the two donnings is reasonable because a majority of existing respirator families can achieve an PPR of >50% using this criterion

  14. Modified Test Protocol Improves Sensitivity of the Stereo Fly Test.

    PubMed

    De La Cruz, Angie; Morale, Sarah E; Jost, Reed M; Kelly, Krista R; Birch, Eileen E

    2016-01-01

    Stereoacuity measurement is a common element of pediatric ophthalmic examinations. Although the Stereo Fly Test is routinely used to establish the presence of coarse stereopsis (3000 arcsecs), it often yields a false negative "pass" due to learned responses and non-stereoscopic cues. We developed and evaluated a modified Stereo Fly Test protocol aimed at increasing sensitivity, thus reducing false negatives. The Stereo Fly Test was administered according to manufacturer instructions to 321 children aged 3-12 years. Children with a "pass" outcome (n = 147) were re-tested wearing glasses fitted with polarizers of matching orientation for both eyes to verify that they were responding to stereoscopic cues (modified protocol). The response to the standard Stereo Fly Test was considered a false negative (pass) if the child still pinched above the plate after disparity cues were eliminated. Randot ® Preschool Stereoacuity and Butterfly Tests were used as gold standards. Sensitivity was 81% (95% CI: 0.75 - 0.86) for standard administration of the Stereo Fly Test (19% false negative "pass"). The modified protocol increased sensitivity to 90% (95% CI: 0.85 - 0.94). The modified two-step protocol is a simple and convenient way to administer the Stereo Fly Test with increased sensitivity in a clinical setting. © 2016 Board of regents of the University of Wisconsin System, American Orthoptic Journal, Volume 66, 2016, ISSN 0065-955X, E-ISSN 1553-4448.

  15. Pilot Testing a Cognitive-Behavioral Protocol on Psychosocial Predictors of Exercise, Nutrition, Weight, and Body Satisfaction Changes in a College-Level Health-Related Fitness Course

    ERIC Educational Resources Information Center

    Annesi, James J.; Howton, Amy; Johnson, Ping H.; Porter, Kandice J.

    2015-01-01

    Objective: Small-scale pilot testing of supplementing a required college health-related fitness course with a cognitive-behavioral exercise-support protocol (The Coach Approach). Participants: Three classes were randomly assigned to Usual processes (n = 32), Coach Approach-supplemented: Mid-size Groups (n = 32), and Coach Approach-supplemented:…

  16. Development of an Advanced Respirator Fit-Test Headform

    PubMed Central

    Bergman, Michael S.; Zhuang, Ziqing; Hanson, David; Heimbuch, Brian K.; McDonald, Michael J.; Palmiero, Andrew J.; Shaffer, Ronald E.; Harnish, Delbert; Husband, Michael; Wander, Joseph D.

    2015-01-01

    Improved respirator test headforms are needed to measure the fit of N95 filtering facepiece respirators (FFRs) for protection studies against viable airborne particles. A Static (i.e., non-moving, non-speaking) Advanced Headform (StAH) was developed for evaluating the fit of N95 FFRs. The StAH was developed based on the anthropometric dimensions of a digital headform reported by the National Institute for Occupational Safety and Health (NIOSH) and has a silicone polymer skin with defined local tissue thicknesses. Quantitative fit factor evaluations were performed on seven N95 FFR models of various sizes and designs. Donnings were performed with and without a pre-test leak checking method. For each method, four replicate FFR samples of each of the seven models were tested with two donnings per replicate, resulting in a total of 56 tests per donning method. Each fit factor evaluation was comprised of three 86-sec exercises: “Normal Breathing” (NB, 11.2 liters per min (lpm)), “Deep Breathing” (DB, 20.4 lpm), then NB again. A fit factor for each exercise and an overall test fit factor were obtained. Analysis of variance methods were used to identify statistical differences among fit factors (analyzed as logarithms) for different FFR models, exercises, and testing methods. For each FFR model and for each testing method, the NB and DB fit factor data were not significantly different (P > 0.05). Significant differences were seen in the overall exercise fit factor data for the two donning methods among all FFR models (pooled data) and in the overall exercise fit factor data for the two testing methods within certain models. Utilization of the leak checking method improved the rate of obtaining overall exercise fit factors ≥100. The FFR models, which are expected to achieve overall fit factors ≥ 100 on human subjects, achieved overall exercise fit factors ≥ 100 on the StAH. Further research is needed to evaluate the correlation of FFRs fitted on the StAH to

  17. "Finding the Right FIT": Rural Patient Preferences for Fecal Immunochemical Test (FIT) Characteristics.

    PubMed

    Pham, Robyn; Cross, Suzanne; Fernandez, Bianca; Corson, Kathryn; Dillon, Kristen; Yackley, Coco; Davis, Melinda M

    2017-01-01

    Colorectal cancer (CRC) is the third leading cause of cancer death in the United States, yet 1 in 3 Americans have never been screened for CRC. Annual screening using fecal immunochemical tests (FITs) is often a preferred modality in populations experiencing CRC screening disparities. Although multiple studies evaluate the clinical effectiveness of FITs, few studies assess patient preferences toward kit characteristics. We conducted this community-led study to assess patient preferences for FIT characteristics and to use study findings in concert with clinical effectiveness data to inform regional FIT selection. We collaborated with local health system leaders to identify FITs and recruit age eligible (50 to 75 years), English or Spanish speaking community members. Participants completed up to 6 FITs and associated questionnaires and were invited to participate in a follow-up focus group. We used a sequential explanatory mixed-methods design to assess participant preferences and rank FIT kits. First, we used quantitative data from user testing to measure acceptability, ease of completion, and specimen adequacy through a descriptive analysis of 1) fixed response questionnaire items on participant attitudes toward and experiences with FIT kits, and 2) a clinical assessment of adherence to directions regarding collection, packaging, and return of specimens. Second, we analyzed qualitative data from focus groups to refine FIT rankings and gain deeper insight into the pros and cons associated with each tested kit. Seventy-six FITs were completed by 18 participants (Range, 3 to 6 kits per participant). Over half (56%, n = 10) of the participants were Hispanic and 50% were female (n = 9). Thirteen participants attended 1 of 3 focus groups. Participants preferred FITs that were single sample, used a probe and vial for sample collection, and had simple, large-font instructions with colorful pictures. Participants reported challenges using paper to catch samples, had

  18. Leak test fitting

    DOEpatents

    Pickett, P.T.

    A hollow fitting for use in gas spectrometry leak testing of conduit joints is divided into two generally symmetrical halves along the axis of the conduit. A clip may quickly and easily fasten and unfasten the halves around the conduit joint under test. Each end of the fitting is sealable with a yieldable material, such as a piece of foam rubber. An orifice is provided in a wall of the fitting for the insertion or detection of helium during testing. One half of the fitting also may be employed to test joints mounted against a surface.

  19. Leak test fitting

    DOEpatents

    Pickett, Patrick T.

    1981-01-01

    A hollow fitting for use in gas spectrometry leak testing of conduit joints is divided into two generally symmetrical halves along the axis of the conduit. A clip may quickly and easily fasten and unfasten the halves around the conduit joint under test. Each end of the fitting is sealable with a yieldable material, such as a piece of foam rubber. An orifice is provided in a wall of the fitting for the insertion or detection of helium during testing. One half of the fitting also may be employed to test joints mounted against a surface.

  20. Qualified Fitness and Exercise as Professionals and Exercise Prescription: Evolution of the PAR-Q and Canadian Aerobic Fitness Test.

    PubMed

    Shephard, Roy J

    2015-04-01

    Traditional approaches to exercise prescription have included a preliminary medical screening followed by exercise tests of varying sophistication. To maximize population involvement, qualified fitness and exercise professionals (QFEPs) have used a self-administered screening questionnaire (the Physical Activity Readiness Questionnaire, PAR-Q) and a simple measure of aerobic performance (the Canadian Aerobic Fitness Test, CAFT). However, problems have arisen in applying the original protocol to those with chronic disease. Recent developments have addressed these issues. Evolution of the PAR-Q and CAFT protocol is reviewed from their origins in 1974 to the current electronic decision tree model of exercise screening and prescription. About a fifth of apparently healthy adults responded positively to the original PAR-Q instrument, thus requiring an often unwarranted referral to a physician. Minor changes of wording did not overcome this problem. However, a consensus process has now developed an electronic decision tree for stratification of exercise risk not only for healthy individuals, but also for those with various types of chronic disease. The new approach to clearance greatly reduces physician referrals and extends the role of QFEPs. The availability of effective screening and simple fitness testing should contribute to the goal of maximizing physical activity in the entire population.

  1. Optimized protocol for quantitative multiple reaction monitoring-based proteomic analysis of formalin-fixed, paraffin embedded tissues

    PubMed Central

    Kennedy, Jacob J.; Whiteaker, Jeffrey R.; Schoenherr, Regine M.; Yan, Ping; Allison, Kimberly; Shipley, Melissa; Lerch, Melissa; Hoofnagle, Andrew N.; Baird, Geoffrey Stuart; Paulovich, Amanda G.

    2016-01-01

    Despite a clinical, economic, and regulatory imperative to develop companion diagnostics, precious few new biomarkers have been successfully translated into clinical use, due in part to inadequate protein assay technologies to support large-scale testing of hundreds of candidate biomarkers in formalin-fixed paraffin embedded (FFPE) tissues. While the feasibility of using targeted, multiple reaction monitoring-mass spectrometry (MRM-MS) for quantitative analyses of FFPE tissues has been demonstrated, protocols have not been systematically optimized for robust quantification across a large number of analytes, nor has the performance of peptide immuno-MRM been evaluated. To address this gap, we used a test battery approach coupled to MRM-MS with the addition of stable isotope labeled standard peptides (targeting 512 analytes) to quantitatively evaluate the performance of three extraction protocols in combination with three trypsin digestion protocols (i.e. 9 processes). A process based on RapiGest buffer extraction and urea-based digestion was identified to enable similar quantitation results from FFPE and frozen tissues. Using the optimized protocols for MRM-based analysis of FFPE tissues, median precision was 11.4% (across 249 analytes). There was excellent correlation between measurements made on matched FFPE and frozen tissues, both for direct MRM analysis (R2 = 0.94) and immuno-MRM (R2 = 0.89). The optimized process enables highly reproducible, multiplex, standardizable, quantitative MRM in archival tissue specimens. PMID:27462933

  2. Performance of a quantitative fecal immunochemical test for detecting advanced colorectal neoplasia: a prospective cohort study.

    PubMed

    Liles, Elizabeth G; Perrin, Nancy; Rosales, Ana G; Smith, David H; Feldstein, Adrianne C; Mosen, David M; Levin, Theodore R

    2018-05-02

    The fecal immunochemical test (FIT) is easier to use and more sensitive than the guaiac fecal occult blood test, but it is unclear how to optimize FIT performance. We compared the sensitivity and specificity for detecting advanced colorectal neoplasia between single-sample (1-FIT) and two-sample (2-FIT) FIT protocols at a range of hemoglobin concentration cutoffs for a positive test. We recruited 2,761 average-risk men and women ages 49-75 referred for colonoscopy within a large nonprofit, group-model health maintenance organization (HMO), and asked them to complete two separate single-sample FITs. We generated receiver-operating characteristic (ROC) curves to compare sensitivity and specificity estimates for 1-FIT and 2-FIT protocols among those who completed both FIT kits and colonoscopy. We similarly compared sensitivity and specificity between hemoglobin concentration cutoffs for a single-sample FIT. Differences in sensitivity and specificity between the 1-FIT and 2-FIT protocols were not statistically significant at any of the pre-specified hemoglobin concentration cutoffs (10, 15, 20, 25, and 30 μg/g). There was a significant difference in test performance of the one-sample FIT between 50 ng/ml (10 μg/g) and each of the higher pre-specified cutoffs. Disease prevalence was low. A two-sample FIT is not superior to a one-sample FIT in detection of advanced adenomas; the one-sample FIT at a hemoglobin concentration cutoff of 50 ng/ml (10 μg/g) is significantly more sensitive for advanced adenomas than at higher cutoffs. These findings apply to a population of younger, average-risk patients in a U.S. integrated care system with high rates of prior screening.

  3. [ALPHA-fitness test battery: health-related field-based fitness tests assessment in children and adolescents].

    PubMed

    Ruiz, J R; España Romero, V; Castro Piñero, J; Artero, E G; Ortega, F B; Cuenca García, M; Jiménez Pavón, D; Chillón, P; Girela Rejón, Ma J; Mora, J; Gutiérrez, A; Suni, J; Sjöstrom, M; Castillo, M J

    2011-01-01

    Hereby we summarize the work developed by the ALPHA (Assessing Levels of Physical Activity) Study and describe the tests included in the ALPHA health-related fitness test battery for children and adolescents. The evidence-based ALPHA-Fitness test battery include the following tests: 1) the 20 m shuttle run test to assess cardiorespiratory fitness; 2) the handgrip strength and 3) standing broad jump to assess musculoskeletal fitness, and 4) body mass index, 5) waist circumference; and 6) skinfold thickness (triceps and subscapular) to assess body composition. Furthermore, we include two versions: 1) the high priority ALPHA health-related fitness test battery, which comprises all the evidence-based fitness tests except the measurement of the skinfold thickness; and 2) the extended ALPHA health-related fitness tests battery for children and adolescents, which includes all the evidence-based fitness tests plus the 4 x 10 m shuttle run test to assess motor fitness.

  4. CAPTIONALS: A computer aided testing environment for the verification and validation of communication protocols

    NASA Technical Reports Server (NTRS)

    Feng, C.; Sun, X.; Shen, Y. N.; Lombardi, Fabrizio

    1992-01-01

    This paper covers the verification and protocol validation for distributed computer and communication systems using a computer aided testing approach. Validation and verification make up the so-called process of conformance testing. Protocol applications which pass conformance testing are then checked to see whether they can operate together. This is referred to as interoperability testing. A new comprehensive approach to protocol testing is presented which address: (1) modeling for inter-layer representation for compatibility between conformance and interoperability testing; (2) computational improvement to current testing methods by using the proposed model inclusive of formulation of new qualitative and quantitative measures and time-dependent behavior; (3) analysis and evaluation of protocol behavior for interactive testing without extensive simulation.

  5. Well-being, health and fitness of children who use wheelchairs: feasibility study protocol to develop child-centred 'keep-fit' exercise interventions.

    PubMed

    O'Brien, Thomas D; Noyes, Jane; Spencer, Llinos Haf; Kubis, Hans-Peter; Edwards, Rhiannon T; Bray, Nathan; Whitaker, Rhiannon

    2015-02-01

    To undertake the pre-clinical and modelling phases of the Medical Research Council complex intervention framework to underpin development of child-centred 'keep-fit', exercise and physical activity interventions for children and young people who use wheelchairs. Children who use wheelchairs face many barriers to participation in physical activity, which compromises fitness, obesity, well-being and health. 'Keep-fit' programmes that are child-centred and engaging are urgently required to enhance participation of disabled children and their families as part of a healthy lifestyle. Nurses will likely be important in promoting and monitoring 'keep-fit' intervention(s) when implemented in the community. Mixed-method (including economic analysis) feasibility study to capture child and family preferences and keep-fit needs and to determine outcome measures for a 'keep-fit' intervention. The study comprises three stages. Stage 1 includes a mixed-method systematic review of effectiveness, cost effectiveness and key stakeholder views and experiences of keep-fit interventions, followed by qualitative interviews with children, young people and their parents to explore preferences and motivations for physical activity. Stage 2 will identify standardized outcome measures and test their application with children who use wheelchairs to obtain baseline fitness data. Options for an exercise-based keep-fit intervention will then be designed based on Stage 1 and 2 findings. In stage 3, we will present intervention options for feedback and further refinement to children and parents/carers in focus groups. (Project funded October 2012). At completion, this study will lead to the design of the intervention and a protocol to test its efficacy. © 2014 John Wiley & Sons Ltd.

  6. Fitness Testing Athletes

    PubMed Central

    Cumming, Gordon R.

    1970-01-01

    Fitness testing of athletes can be subdivided into tests of body build, strength, aerobic power, and tests specific to the athletic event. World class athletes seem to fall into specific body types for the individual events. The top athlete usually has very little of the endomorphic characteristics and should be lean. Strength testing should be used more frequently as weight and isometric training techniques are used by many athletes and coaches without specific goals. The aerobic power of many national class athletes may be only 10-30 percent above that of the general population, and high values were found only in cyclists and distance runners. It is emphasized that the scores of fitness tests are specific for each test and do not necessarily correlate at all with athletic performance which is also specific. Despite this limitation, fitness tests do have a place in athletics and should be utilized more fully and with more understanding by coaches and athletes. Imagesp48-a PMID:20468546

  7. Materials testing protocol for small joint prostheses.

    PubMed

    Savory, K M; Hutchinson, D T; Bloebaum, R

    1994-10-01

    In this article, a protocol for the evaluation of new materials for small joint prostheses is introduced. The testing methods employed in the protocol were developed by reviewing reported clinical failure modes and conditions found in vivo. The methods developed quantitatively evaluates the fatigue, fatigue crack propagation, and wear resistance properties of materials. For this study, a silicone elastomer similar to Dow Corning Silastic HP100, a radiation stable polypropylene, and a copolymer of polypropylene and ethylene propylene-diene monomer (EPDM) are evaluated. None of the materials tested demonstrated the ideal properties that are sought in a self-hinging joint prostheses. The silicone elastomer had excellent wear properties; however, cracks quickly propagated, causing catastrophic failure when fatigued. Conversely, the copolymer showed excellent fatigue crack propagation resistance and less than favorable wear properties. The polypropylene did not perform well in any evaluation.

  8. Anaerobic fitness tests: what are we measuring?

    PubMed

    Van Praagh, Emmanuel

    2007-01-01

    Anaerobic fitness, during growth and development, has not received the same attention from researchers as aerobic fitness. This is surprising given the level of anaerobic energy used daily during childhood and adolescence. During physical activity and sport, the child is spontaneously more attracted to short-burst movements than to long-term activities. It is, however, well known that in anaerobic activities such as sprint cycling, sprint running or sprint swimming, the child's performance is distinctly poorer than that of the adult. This partly reflects the child's lesser ability to generate mechanical energy from chemical energy sources during short-term high-intensity work or exercise. Direct measurements of the rate or capacity of anaerobic pathways for energy turnover presents several ethical and methodological difficulties. Therefore, rather than measure energy supply, pediatric exercise scientists have concentrated on measuring short-term power output by means of standardized protocol tests such as short-term cycling power tests, running tests or vertical jump tests. There is, however, no perfect test and, therefore, it is important to acknowledge the benefits and limitations of each testing method. Mass-related short-term power output was shown to increase dramatically during growth and development, whereas the corresponding increase in peak blood lactate was considerably lower. This suggests that the observed difference between children and adolescents during short-term power output testing may be related to neuromuscular factors, hormonal factors and improved motor coordination.

  9. Quantitative Sensory Testing in Adults with Autism Spectrum Disorders

    ERIC Educational Resources Information Center

    Fründt, Odette; Grashorn, Wiebke; Schöttle, Daniel; Peiker, Ina; David, Nicole; Engel, Andreas K.; Forkmann, Katarina; Wrobel, Nathalie; Münchau, Alexander; Bingel, Ulrike

    2017-01-01

    Altered sensory perception has been found in patients with autism spectrum disorders (ASD) and might be related to aberrant sensory perception thresholds. We used the well-established, standardized Quantitative sensory testing (QST) protocol of the German Research Network on Neuropathic Pain to investigate 13 somatosensory parameters including…

  10. The Functional Fitness MOT Test Battery for Older Adults: Protocol for a Mixed-Method Feasibility Study.

    PubMed

    de Jong, Lex D; Peters, Andy; Hooper, Julie; Chalmers, Nina; Henderson, Claire; Laventure, Robert Me; Skelton, Dawn A

    2016-06-20

    Increasing physical activity (PA) brings many health benefits, but engaging people in higher levels of PA after their 60s is not straightforward. The Functional Fitness MOT (FFMOT) is a new approach which aims to raise awareness about the importance of components of fitness (strength, balance, flexibility), highlight benefits of PA, engages older people in health behavior change discussions, and directs them to local activity resources. This battery of tests combined with a brief motivational interview has not been tested in terms of feasibility or effectiveness. To assess whether the FFMOT, provided in a health care setting, is appealing to older patients of a community physiotherapy service and to understand the views and perceptions of the older people undergoing the FFMOT regarding the intervention, as well as the views of the physiotherapy staff delivering the intervention. Secondary aims are to assess the feasibility of carrying out a phase 2 pilot randomized controlled trial of the FFMOT, in the context of a community physiotherapy service, by establishing whether enough patients can be recruited and retained in the study, and enough outcome data can be generated. A mixed-methods feasibility study will be conducted in two physiotherapy outpatient clinics in the United Kingdom. A total of 30 physically inactive, medically stable older adults over the age of 60 will be provided with an individual FFMOT, comprising a set of six standardized, validated, age-appropriate tests aimed at raising awareness of the different components of fitness. The results of these tests will be used to provide the participants with feedback on performance in comparison to sex and age-referenced norms. This will be followed by tailored advice on how to become more active and improve fitness, including advice on local opportunities to be more active. Subsequently, participants will be invited to attend a focus group to discuss barriers and motivators to being more active, health

  11. Respirator Qualitative/Quantitative Fit Test Method Analysis

    DTIC Science & Technology

    1980-08-01

    carefully fitted to sample the atmosphere in the oral/ nasal or visual cavity. Leakage is expressed as a ratio of the ambient challenge atmosphere...8, 10, 40, 205, 274). While cer- Lain counercial polymer films have reportedly caused fibrosarcomas and other tumors in rats, this has been attributed... nasal passages (Portland cement dust), or cause injury to the skin or mucous membranes by chemical or mechanical action per se or by the rigorous skin

  12. Development of a calibration protocol for quantitative imaging for molecular radiotherapy dosimetry

    NASA Astrophysics Data System (ADS)

    Wevrett, J.; Fenwick, A.; Scuffham, J.; Nisbet, A.

    2017-11-01

    Within the field of molecular radiotherapy, there is a significant need for standardisation in dosimetry, in both quantitative imaging and dosimetry calculations. Currently, there are a wide range of techniques used by different clinical centres and as a result there is no means to compare patient doses between centres. To help address this need, a 3 year project was funded by the European Metrology Research Programme, and a number of clinical centres were involved in the project. One of the required outcomes of the project was to develop a calibration protocol for three dimensional quantitative imaging of volumes of interest. Two radionuclides were selected as being of particular interest: iodine-131 (131I, used to treat thyroid disorders) and lutetium-177 (177Lu, used to treat neuroendocrine tumours). A small volume of activity within a scatter medium (water), representing a lesion within a patient body, was chosen as the calibration method. To ensure ease of use in clinical centres, an "off-the-shelf" solution was proposed - to avoid the need for in-house manufacturing. The BIODEX elliptical Jaszczak phantom and 16 ml fillable sphere were selected. The protocol was developed for use on SPECT/CT gamma cameras only, where the CT dataset would be used to correct the imaging data for attenuation of the emitted photons within the phantom. The protocol corrects for scatter of emitted photons using the triple energy window correction technique utilised by most clinical systems. A number of clinical systems were tested in the development of this protocol, covering the major manufacturers of gamma camera generally used in Europe. Initial imaging was performed with 131I and 177Lu at a number of clinical centres, but due to time constraints in the project, some acquisitions were performed with 177Lu only. The protocol is relatively simplistic, and does not account for the effects of dead-time in high activity patients, the presence of background activity surrounding

  13. A protocol for the health and fitness assessment of NBA players.

    PubMed

    Scheller, A; Rask, B

    1993-04-01

    The assessment of the health and fitness of elite basketball players should be a multidisciplinary process. We have described an organized, efficient, and comprehensive protocol for preseason physical evaluations that could be used at the university as well as professional level.

  14. Crash Testing of Helicopter Airframe Fittings

    NASA Technical Reports Server (NTRS)

    Clarke, Charles W.; Townsend, William; Boitnott, Richard

    2004-01-01

    As part of the Rotary Wing Structures Technology Demonstration (RWSTD) program, a surrogate RAH-66 seat attachment fitting was dynamically tested to assess its response to transient, crash impact loads. The dynamic response of this composite material fitting was compared to the performance of an identical fitting subjected to quasi-static loads of similar magnitude. Static and dynamic tests were conducted of both smaller bench level and larger full-scale test articles. At the bench level, the seat fitting was supported in a steel fixture, and in the full-scale tests, the fitting was integrated into a surrogate RAH-66 forward fuselage. Based upon the lessons learned, an improved method to design, analyze, and test similar composite material fittings is proposed.

  15. Understanding protocol performance: impact of test performance.

    PubMed

    Turner, Robert G

    2013-01-01

    This is the second of two articles that examine the factors that determine protocol performance. The objective of these articles is to provide a general understanding of protocol performance that can be used to estimate performance, establish limits on performance, decide if a protocol is justified, and ultimately select a protocol. The first article was concerned with protocol criterion and test correlation. It demonstrated the advantages and disadvantages of different criterion when all tests had the same performance. It also examined the impact of increasing test correlation on protocol performance and the characteristics of the different criteria. To examine the impact on protocol performance when individual tests in a protocol have different performance. This is evaluated for different criteria and test correlations. The results of the two articles are combined and summarized. A mathematical model is used to calculate protocol performance for different protocol criteria and test correlations when there are small to large variations in the performance of individual tests in the protocol. The performance of the individual tests that make up a protocol has a significant impact on the performance of the protocol. As expected, the better the performance of the individual tests, the better the performance of the protocol. Many of the characteristics of the different criteria are relatively independent of the variation in the performance of the individual tests. However, increasing test variation degrades some criteria advantages and causes a new disadvantage to appear. This negative impact increases as test variation increases and as more tests are added to the protocol. Best protocol performance is obtained when individual tests are uncorrelated and have the same performance. In general, the greater the variation in the performance of tests in the protocol, the more detrimental this variation is to protocol performance. Since this negative impact is increased as

  16. Protocol for quantitative tracing of surface water with synthetic DNA

    NASA Astrophysics Data System (ADS)

    Foppen, J. W.; Bogaard, T. A.

    2012-04-01

    , the field tests were performed with salt and deuterium as tracer. To study possible decay by sunlight and/or microbial activity for synthetic DNA, immediately in the field and for the duration of the entire experiment, we carried out batch experiments. All samples were stored in a 1.5 ml Eppendorf vial in a cool-box in dry ice (-80°C). Quantitative PCR on a Mini Opticon (Bio Rad, Hercules, CA, USA) was carried out to determine DNA concentrations in the samples. Results showed the importance of a strict protocol for working with ssDNA as a tracer for quantitative tracing, since ssDNA interacts with surface areas of glass and plastic, depending on water quality and ionic strength. Interaction with the sediment and decay due to sunlight and/or microbial activity was negligible in most cases. The ssDNA protocol was then tested in natural streams. Promising results were obtained using ssDNA as quantitative tracer. The breakthrough curves using ssDNA were similar to the ones of salt or deuterium. We will present the revised protocol to use ssDNA for multi-tracing experiments in natural streams and discuss the opportunities and limitations.

  17. Relationships Among Two Repeated Activity Tests and Aerobic Fitness of Volleyball Players.

    PubMed

    Meckel, Yoav; May-Rom, Moran; Ekshtien, Aya; Eisenstein, Tamir; Nemet, Dan; Eliakim, Alon

    2015-08-01

    The purpose of the study was to determine performance indices of a repeated sprint test (RST) and to examine their relationships with performance indices of a repeated jump test (RJT) and with aerobic fitness among trained volleyball players. Sixteen male volleyball players performed RST (6 × 30 m sprints), RJT (6 sets of 6 consecutive jumps), and an aerobic power test (20-m Shuttle Run Test). Performance indices for the RST and the RJT were (a) the ideal 30-m run time (IS), the total run time (TS) of the 6 sprints, and the performance decrement (PD) during the test and (b) the ideal jump height (IJ), the total jump height (TJ) of all the jumps, and the PD during the test, respectively. No significant correlations were found between performance indices of the RST and RJT. Significant correlations were found between PD, IS, and TS in the RST protocol and predicted peak V[Combining Dot Above]O2 (r = -0.60, -0.75, -0.77, respectively). No significant correlations were found between performance indices of the RJT (IJ, TJ, and PD) and peak V[Combining Dot Above]O2. The findings suggest that a selection of repeated activity test protocols should acknowledge the specific technique used in the sport, and that a distinct RJT, rather than the classic RST, is more appropriate for assessing the anaerobic capabilities of volleyball players. The findings also suggest that aerobic fitness plays only a minor role in performance maintenance throughout characteristic repeated jumping activity of a volleyball game.

  18. "Not just another Wii training": a graded Wii protocol to increase physical fitness in adolescent girls with probable developmental coordination disorder-a pilot study.

    PubMed

    Bonney, Emmanuel; Rameckers, Eugene; Ferguson, Gillian; Smits-Engelsman, Bouwien

    2018-02-22

    Adolescents with low motor competence participate less in physical activity and tend to exhibit decreased physical fitness compared to their peers with high motor competence. It is therefore essential to identify new methods of enhancing physical fitness in this population. Active video games (AVG) have been shown to improve motor performance, yet investigations of its impact on physical fitness are limited. The objective of this study was to examine the impact of the graded Wii protocol in adolescent girls with probable Developmental Coordination Disorder (p-DCD). A single-group pre-post design was conducted to assess the impact of a newly developed Wii protocol in adolescent girls attending school in a low income community of Cape Town, South Africa. Sixteen participants (aged 13-16 years) with p-DCD (≤16th percentile on the MABC-2 test) were recruited. Participants received 45 min Wii training for 14 weeks. Outcome measures included the six-minute walk distance and repeated sprint ability. Information on heart rate, enjoyment and perceived exertion ratings were also collected. Significant improvements in aerobic and anaerobic fitness were observed. The participants reported high enjoyment scores and low perceived exertion ratings. The graded Wii protocol was easily adaptable and required little resources (space, equipment and expertise) to administer. The findings provide preliminary evidence to support the use of the graded Wii protocol for promoting physical fitness in adolescent girls with p-DCD. Further studies are needed to confirm these results and to validate the clinical efficacy of the protocol in a larger sample with a more robust design.

  19. Indirect scaling methods for testing quantitative emotion theories.

    PubMed

    Junge, Martin; Reisenzein, Rainer

    2013-01-01

    Two studies investigated the utility of indirect scaling methods, based on graded pair comparisons, for the testing of quantitative emotion theories. In Study 1, we measured the intensity of relief and disappointment caused by lottery outcomes, and in Study 2, the intensity of disgust evoked by pictures, using both direct intensity ratings and graded pair comparisons. The stimuli were systematically constructed to reflect variables expected to influence the intensity of the emotions according to theoretical models of relief/disappointment and disgust, respectively. Two probabilistic scaling methods were used to estimate scale values from the pair comparison judgements: Additive functional measurement (AFM) and maximum likelihood difference scaling (MLDS). The emotion models were fitted to the direct and indirect intensity measurements using nonlinear regression (Study 1) and analysis of variance (Study 2). Both studies found substantially improved fits of the emotion models for the indirectly determined emotion intensities, with their advantage being evident particularly at the level of individual participants. The results suggest that indirect scaling methods yield more precise measurements of emotion intensity than rating scales and thereby provide stronger tests of emotion theories in general and quantitative emotion theories in particular.

  20. Reliability and Accuracy of a Standardized Shallow Water Running Test to Determine Cardiorespiratory Fitness.

    PubMed

    Nagle, Elizabeth F; Sanders, Mary E; Gibbs, Bethany B; Franklin, Barry A; Nagle, Jacquelyn A; Prins, Philip J; Johnson, Caleb D; Robertson, Robert J

    2017-06-01

    A standardized fitness assessment is critical for the development of an individualized exercise prescription. Although the benefits of aquatic exercise have been well established, there remains the need for a standardized nonswimming protocol to accurately assess cardiorespiratory fitness (CRF) in shallow water. The present investigation was designed to assess (a) the reliability of a standardized shallow water run (SWR) test of CRF and (b) the accuracy of a standardized SWR compared with a land-based treadmill (LTM) test. Twenty-three healthy women (20 ± 3 years), with body mass index (23.5 ± 3 kg·m), performed 2 shallow water peak oxygen consumption (V[Combining Dot Above]O2peak) running tests (SWRa and SWRb), and 1 V[Combining Dot Above]O2max LTM. Intraclass correlation coefficients indicated moderately strong reliability for V[Combining Dot Above]O2peak (ml·kg·min) (r = 0.73, p < 0.01), HRpeak (b·min) (r = 0.82; p < 0.01), and O2pulse (V[Combining Dot Above]O2 [ml·kg·min]·HR [b·min]) (r = 0.77, p < 0.01). Using paired t-tests and Pearson's correlations, SWR V[Combining Dot Above]O2peak and HRpeak were significantly lower than during LTM (p ≤ 0.05) and showed moderate correlations of 0.60 and 0.58 (p < 0.001) to LTM. O2pulse was similar (p > 0.05) for the SWR and LTM tests with a moderate correlation of 0.63. A standardized SWR test as a measure of CRF is a reliable, and to some degree, valid alternative to conventional protocols and may be used by strength and conditioning professionals to measure program outcomes and monitor training progress. Furthermore, this protocol provides a water-based option for CRF assessment among healthy women and offers insight toward the development of an effective protocol that can accommodate individuals with limited mobility, or those seeking less musculoskeletal impact from traditional land-based types of training.

  1. Respiratory fit testing for farmworkers in the Black Dirt region of Hudson Valley, New York.

    PubMed

    Earle-Richardson, Giulia; Fiske, Todd; Wyckoff, Sherry; Shuford, James; May, John

    2014-01-01

    Respiratory protection in agriculture has lagged behind other industries. Migrant farmworkers often work in dusty environments yet do not receive appropriate, fitted respiratory protection. During May and June of 2013, researchers pilot-tested a respiratory protection program adapted to fit the unique needs of migrant and seasonal farmworkers. It was implemented in Spanish, with literacy support, at convenient times and locations. Additionally, staff was known to workers, and a farmworker medical center provided medical follow-up. Fifty-six farmworkers participated (68%; 82 invited). Of the participants, 88% were male; 20% reported using respiratory protection. One worker had been fit tested previously; 57% reported being exposed to pesticides. All but six farmworkers passed the medical clearance (91%). The mask most commonly fit to the American-born population was a good fit for only 41% of Latino farmworkers. The fact that two thirds of invited farmworkers participated in the clearance and over half completed mask fitting indicates that the modified protocol meets farmworker needs. A wide range of mask types should be made available for Latino farmworkers.

  2. [Professional divers: analysis of critical issues and proposal of a health protocol for work fitness].

    PubMed

    Pedata, Paola; Corvino, Anna Rita; Napolitano, Raffaele Carmine; Garzillo, Elpidio Maria; Furfaro, Ciro; Lamberti, Monica

    2016-01-20

    From many years now, thanks to the development of modern diving techniques, there has been a rapid spread of diving activities everywhere. In fact, divers are ever more numerous both among the Armed Forces and civilians who dive for work, like fishing, biological research and archeology. The aim of the study was to propose a health protocol for work fitness of professional divers keeping in mind the peculiar work activity, existing Italian legislation that is almost out of date and the technical and scientific evolution in this occupational field. We performed an analysis of the most frequently occurring diseases among professional divers and of the clinical investigation and imaging techniques used for work fitness assessment of professional divers. From analysis of the health protocol recommended by D.M. 13 January 1979 (Ministerial Decree), that is most used by occupational health physician, several critical issues emerged. Very often the clinical investigation and imaging techniques still used are almost obsolete, ignoring the execution of simple and inexpensive investigations that are more useful for work fitness assessment. Considering the out-dated legislation concerning diving disciplines, it is necessary to draw up a common health protocol that takes into account clinical and scientific knowledge and skills acquired in this area. This protocol's aim is to propose a useful tool for occupational health physicians who work in this sector.

  3. Circumferential fit assessment of CAD/CAM single crowns--a pilot investigation on a new virtual analytical protocol.

    PubMed

    Matta, Ragai E; Schmitt, Johannes; Wichmann, Manfred; Holst, Stefan

    2012-10-01

    Techniques currently applied to determine the marginal accuracy of dental crown restorations yield inadequate information. This investigation aimed to test a new virtual approach for determining the precision of fit of single-crown copings. Zirconia single crown copings were manufactured on 10 gypsum, single-tooth master casts with two different established computer-aided design/computer-assisted manufacture (CAD/CAM) systems (groups A and B). After cementation, the circumferential fit was assessed with an industrial noncontact scanner and virtual 3D analysis, following a triple-scan protocol. Marginal fit was determined by virtual sectioning; each abutment-coping complex was digitally sliced in 360 vertical sections (1 degree per section). Standardized measurement distances for analyzing the marginal fit (z, xy, xyz) were selected, and a crosshair alignment was utilized to determine whether crowns were horizontally and/or vertically too large or small. The Mann-Whitney test was applied to test for differences between groups. Significant differences in the xy direction (P = .008) were measured between groups. Group A showed a greater number of horizontally overextended margins and a higher frequency of xy distances greater than 150 Μm, in addition to a tendency for excessive z distances (P = .095). The mean marginal gap values were clinically acceptable in the present investigation; however, a full circumferential analysis revealed significant differences in marginal coping quality.

  4. Acclimatization in first-time hearing aid users using three different fitting protocols.

    PubMed

    Reber, Monika Bertges; Kompis, Martin

    2005-12-01

    To study auditory acclimatization and outcome in first time hearing aid users fitted with state of the art hearing aids as a function of different hearing aid fitting protocols. Twenty-eight adult subjects participated in the study. Each subject was assigned to one of three study groups (named audiologist driven, AD; patient driven, PD; set-to-target, STT according to the fitting protocol used) and fitted with digital hearing aids (Bernafon Symbio). Speech recognition scores were measured in aided and unaided conditions over a 6-month period. Five subjects (three from the PD-group, two from the STT group) decided to withdraw from the study during the 6-month-study period, leaving a total of 23 complete data sets for analysis. Aided speech understanding increased significantly over this time period in all three groups. However, average hearing aid insertion gain changes were small over the same period. There were no statistically significant differences in aided or unaided speech recognition scores between the three groups after 2 weeks or after 6 months. On average, twice as many fine tunings of the hearing aids were requested by the patients in the AD and the STT group than in the PD group and subjects in the AD and STT group used their hearing aids approximately twice as much as subjects in the PD group. The substantial increase in speech intelligibility without significant changes of the insertion gain of the hearing aids over a 6-month period in all three groups suggests a significant acclimatization effect. Although the speech recognition with hearing aids did not differ significantly among the three study groups after 6 months, the lower average wearing time and the higher number of withdrawals from the study in the PD group suggest that the patients' needs are not adequately met. In terms of aided speech recognition scores and hearing aid wearing time the STT group and the AD group were very similar. However, comments of the patients and the higher rate of

  5. Comparison of low- and ultralow-dose computed tomography protocols for quantitative lung and airway assessment.

    PubMed

    Hammond, Emily; Sloan, Chelsea; Newell, John D; Sieren, Jered P; Saylor, Melissa; Vidal, Craig; Hogue, Shayna; De Stefano, Frank; Sieren, Alexa; Hoffman, Eric A; Sieren, Jessica C

    2017-09-01

    Quantitative computed tomography (CT) measures are increasingly being developed and used to characterize lung disease. With recent advances in CT technologies, we sought to evaluate the quantitative accuracy of lung imaging at low- and ultralow-radiation doses with the use of iterative reconstruction (IR), tube current modulation (TCM), and spectral shaping. We investigated the effect of five independent CT protocols reconstructed with IR on quantitative airway measures and global lung measures using an in vivo large animal model as a human subject surrogate. A control protocol was chosen (NIH-SPIROMICS + TCM) and five independent protocols investigating TCM, low- and ultralow-radiation dose, and spectral shaping. For all scans, quantitative global parenchymal measurements (mean, median and standard deviation of the parenchymal HU, along with measures of emphysema) and global airway measurements (number of segmented airways and pi10) were generated. In addition, selected individual airway measurements (minor and major inner diameter, wall thickness, inner and outer area, inner and outer perimeter, wall area fraction, and inner equivalent circle diameter) were evaluated. Comparisons were made between control and target protocols using difference and repeatability measures. Estimated CT volume dose index (CTDIvol) across all protocols ranged from 7.32 mGy to 0.32 mGy. Low- and ultralow-dose protocols required more manual editing and resolved fewer airway branches; yet, comparable pi10 whole lung measures were observed across all protocols. Similar trends in acquired parenchymal and airway measurements were observed across all protocols, with increased measurement differences using the ultralow-dose protocols. However, for small airways (1.9 ± 0.2 mm) and medium airways (5.7 ± 0.4 mm), the measurement differences across all protocols were comparable to the control protocol repeatability across breath holds. Diameters, wall thickness, wall area fraction

  6. Pleasure and Pain: Experiences of Fitness Testing

    ERIC Educational Resources Information Center

    Wrench, Alison; Garrett, Robyne

    2008-01-01

    The obesity crisis is a hegemonic discourse that has established common-sense understandings that young people are less active and fit than previous generations. Unquestioning acceptance of links between fitness and obesity in turn leads to unproblematic fitness testing of young people. Argument is made that fitness tests motivate and encourage…

  7. AAHPER Youth Fitness Test Manual. Revised Edition.

    ERIC Educational Resources Information Center

    American Alliance for Health, Physical Education, and Recreation, Washington, DC.

    The Revised AAHPER Youth Fitness Test is a battery of six test items designed to give a measure of physical fitness for boys and girls in grades 5-12. The tests were selected to evaluate specific aspects of physical status which, taken together, give an overall picture of fitness. Tests can be given in the gymnasium or outdoors. They are as…

  8. Comparison of test protocols for standard room/corner tests

    Treesearch

    R. H. White; M. A. Dietenberger; H. Tran; O. Grexa; L. Richardson; K. Sumathipala; M. Janssens

    1998-01-01

    As part of international efforts to evaluate alternative reaction-to-fire tests, several series of room/comer tests have been conducted. This paper reviews the overall results of related projects in which different test protocols for standard room/corner tests were used. Differences in the test protocols involved two options for the ignition burner scenario and whether...

  9. Quantitative Assessment of In-solution Digestion Efficiency Identifies Optimal Protocols for Unbiased Protein Analysis*

    PubMed Central

    León, Ileana R.; Schwämmle, Veit; Jensen, Ole N.; Sprenger, Richard R.

    2013-01-01

    The majority of mass spectrometry-based protein quantification studies uses peptide-centric analytical methods and thus strongly relies on efficient and unbiased protein digestion protocols for sample preparation. We present a novel objective approach to assess protein digestion efficiency using a combination of qualitative and quantitative liquid chromatography-tandem MS methods and statistical data analysis. In contrast to previous studies we employed both standard qualitative as well as data-independent quantitative workflows to systematically assess trypsin digestion efficiency and bias using mitochondrial protein fractions. We evaluated nine trypsin-based digestion protocols, based on standard in-solution or on spin filter-aided digestion, including new optimized protocols. We investigated various reagents for protein solubilization and denaturation (dodecyl sulfate, deoxycholate, urea), several trypsin digestion conditions (buffer, RapiGest, deoxycholate, urea), and two methods for removal of detergents before analysis of peptides (acid precipitation or phase separation with ethyl acetate). Our data-independent quantitative liquid chromatography-tandem MS workflow quantified over 3700 distinct peptides with 96% completeness between all protocols and replicates, with an average 40% protein sequence coverage and an average of 11 peptides identified per protein. Systematic quantitative and statistical analysis of physicochemical parameters demonstrated that deoxycholate-assisted in-solution digestion combined with phase transfer allows for efficient, unbiased generation and recovery of peptides from all protein classes, including membrane proteins. This deoxycholate-assisted protocol was also optimal for spin filter-aided digestions as compared with existing methods. PMID:23792921

  10. Verification of a Proposed Clinical Electroacoustic Test Protocol for Personal Digital Modulation Receivers Coupled to Cochlear Implant Sound Processors.

    PubMed

    Nair, Erika L; Sousa, Rhonda; Wannagot, Shannon

    Guidelines established by the AAA currently recommend behavioral testing when fitting frequency modulated (FM) systems to individuals with cochlear implants (CIs). A protocol for completing electroacoustic measures has not yet been validated for personal FM systems or digital modulation (DM) systems coupled to CI sound processors. In response, some professionals have used or altered the AAA electroacoustic verification steps for fitting FM systems to hearing aids when fitting FM systems to CI sound processors. More recently steps were outlined in a proposed protocol. The purpose of this research is to review and compare the electroacoustic test measures outlined in a 2013 article by Schafer and colleagues in the Journal of the American Academy of Audiology titled "A Proposed Electroacoustic Test Protocol for Personal FM Receivers Coupled to Cochlear Implant Sound Processors" to the AAA electroacoustic verification steps for fitting FM systems to hearing aids when fitting DM systems to CI users. Electroacoustic measures were conducted on 71 CI sound processors and Phonak Roger DM systems using a proposed protocol and an adapted AAA protocol. Phonak's recommended default receiver gain setting was used for each CI sound processor manufacturer and adjusted if necessary to achieve transparency. Electroacoustic measures were conducted on Cochlear and Advanced Bionics (AB) sound processors. In this study, 28 Cochlear Nucleus 5/CP810 sound processors, 26 Cochlear Nucleus 6/CP910 sound processors, and 17 AB Naida CI Q70 sound processors were coupled in various combinations to Phonak Roger DM dedicated receivers (25 Phonak Roger 14 receivers-Cochlear dedicated receiver-and 9 Phonak Roger 17 receivers-AB dedicated receiver) and 20 Phonak Roger Inspiro transmitters. Employing both the AAA and the Schafer et al protocols, electroacoustic measurements were conducted with the Audioscan Verifit in a clinical setting on 71 CI sound processors and Phonak Roger DM systems to

  11. 16 CFR 1212.4 - Test protocol.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Test protocol. 1212.4 Section 1212.4... STANDARD FOR MULTI-PURPOSE LIGHTERS Requirements for Child-Resistance § 1212.4 Test protocol. (a) Child test panel. (1) The test to determine if a multi-purpose lighter is resistant to successful operation...

  12. 16 CFR 1210.4 - Test protocol.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Test protocol. 1210.4 Section 1210.4... STANDARD FOR CIGARETTE LIGHTERS Requirements for Child Resistance § 1210.4 Test protocol. (a) Child test panel. (1) The test to determine if a lighter is resistant to successful operation by children uses a...

  13. Manitoba Schools Fitness 1989.

    ERIC Educational Resources Information Center

    Manitoba Dept. of Education, Winnipeg.

    This manual outlines physical fitness tests that may be used in the schools. The tests are based on criterion standards which indicate the levels of achievement at which health risk factors may be reduced. Test theory, protocols, and criterion charts are presented for: (1) muscle strength and endurance, (2) body composition, (3) flexibility, and…

  14. A Battery Test to Evaluate Life-Time Physical Fitness With Same Test Items.

    ERIC Educational Resources Information Center

    Meshizuka, Tetsuo

    A combination of physical fitness tests designed to be administered to a wide spectrum of the population, male and female, children and adults, is described. Three tests are included in this battery--motor fitness, physical fitness, and sports fitness. The philosophy behind this test structure is that motor fitness tests only measure and indicate…

  15. Effects of Various Warm Up Protocol on Special Judo Fitness Test Performance.

    PubMed

    Lum, Danny

    2017-02-13

    The purposed of this study was to compare the effects of postactivation potentiation (PAP) on Special Judo Fitness Test (SJFT) performance using explosive exercises that activates upper and lower limbs muscles. Eleven male judo athletes (mean ± SD, age, 16 - 29 years; height, 170 ± 7 cm; body mass, 73 ± 16 kg) attended four separate sessions. The first session was used to familiarise the subjects to the experimental procedure, the SJFT, the high pull test (HPT) and the two explosive exercises including resistance band pull and standing broad jump. Subsequently, subjects were randomly assigned in a counterbalanced manner to either perform the upper and lower body PAP (ULB), lower body PAP (LB) or usual competition (CON) warm up routine prior to performing the HPT and SJFT. The following variables were quantified: throws performed during series A, B, and C; total number of throws; heart rate immediately and 1 minute after the test; test index; peak power; and RPE after warm up. During series 1, number of throws performed in LB and ULB were significantly greater than CON (p < 0.05). Only ULB resulted in significantly greater number of total throws (p < 0.01) and higher peak power (p < 0.01) than CON. The RPE for both LB and ULB were significantly lower than CON (p < 0.01). Peak power was moderately correlated to total number of throws performed (r=0.4, p < 0.05). This study suggest that performing ULB before SJFT can result in improved performance and peak power.

  16. 32 CFR 901.6 - Candidate fitness test requirement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 6 2011-07-01 2011-07-01 false Candidate fitness test requirement. 901.6... Requirements § 901.6 Candidate fitness test requirement. Before being offered an appointment, candidates must take a Candidate Fitness Test (CFT) which consists of exercises designed to measure muscular strength...

  17. 32 CFR 901.6 - Candidate fitness test requirement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 6 2010-07-01 2010-07-01 false Candidate fitness test requirement. 901.6... Requirements § 901.6 Candidate fitness test requirement. Before being offered an appointment, candidates must take a Candidate Fitness Test (CFT) which consists of exercises designed to measure muscular strength...

  18. 32 CFR 901.6 - Candidate fitness test requirement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 6 2013-07-01 2013-07-01 false Candidate fitness test requirement. 901.6... Requirements § 901.6 Candidate fitness test requirement. Before being offered an appointment, candidates must take a Candidate Fitness Test (CFT) which consists of exercises designed to measure muscular strength...

  19. 32 CFR 901.6 - Candidate fitness test requirement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 6 2014-07-01 2014-07-01 false Candidate fitness test requirement. 901.6... Requirements § 901.6 Candidate fitness test requirement. Before being offered an appointment, candidates must take a Candidate Fitness Test (CFT) which consists of exercises designed to measure muscular strength...

  20. 32 CFR 901.6 - Candidate fitness test requirement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 6 2012-07-01 2012-07-01 false Candidate fitness test requirement. 901.6... Requirements § 901.6 Candidate fitness test requirement. Before being offered an appointment, candidates must take a Candidate Fitness Test (CFT) which consists of exercises designed to measure muscular strength...

  1. Cardio-pulmonary fitness test by ultra-short heart rate variability.

    PubMed

    Aslani, Arsalan; Aslani, Amir; Kheirkhah, Jalal; Sobhani, Vahid

    2011-10-01

    It is known that exercise induces cardio-respiratory autonomic modulation. The aim of this study was to assess the cardio-pulmonary fitness by ultra-short heart rate variability. Study population was divided into 3 groups: Group-1 (n = 40) consisted of military sports man. Group-2 (n = 40) were healthy age-matched sedentary male subjects with normal body mass index [BMI = 19 - 25 kg/m(2)). Group-3 (n = 40) were healthy age-matched obese male subjects [BMI > 29 kg/m(2)). Standard deviation of normal-to-normal QRS intervals (SDNN) was recorded over 15 minutes. Bruce protocol treadmill test was used; and, maximum oxygen consumption (VO(2)max) was calculated. WHEN THE STUDY POPULATION WAS DIVIDED INTO QUARTILES OF SDNN (FIRST QUARTILE: < 60 msec; second quartile: > 60 and < 100 msec; third quartile: > 100 and <140 msec; and fourth quartile: >140 msec), progressive increase was found in VO(2)max; and, SDNN was significantly linked with estimated VO(2)max. In conclusion, the results of this study demonstrate that exercise training improves cardio-respiratory autonomic function (and increases heart rate variability). Improvement in cardio-respiratory autonomic function seems to translate into a lower rate of long term mortality. Ultra-short heart rate variability is a simple cardio-pulmonary fitness test which just requires 15 minutes, and involves no exercise such as in the treadmill or cycle test.

  2. 'Sportmotorische Bestandesaufnahme': criterion- vs. norm-based reference values of fitness tests for Swiss first grade children.

    PubMed

    Tomatis, Laura; Krebs, Andreas; Siegenthaler, Jessica; Murer, Kurt; de Bruin, Eling D

    2015-01-01

    Health is closely linked to physical activity and fitness. It is therefore important to monitor fitness in children. Although many reports on physical tests have been published, data comparison between studies is an issue. This study reports Swiss first grade norm values of fitness tests and compares these with criterion reference data. A total of 10,565 boys (7.18 ± 0.42 years) and 10,204 girls (7.14 ± 0.41 years) were tested for standing long jump, plate tapping, 20-m shuttle run, lateral jump and 20-m sprint. Average values for six-, seven- and eight-year-olds were analysed and reference curves for age were constructed. Z-values were generated for comparisons with criterion references reported in the literature. Results were better for all disciplines in seven-year-old first grade children compared to six-year-old children (p < 0.01). Eight-year-old children did not perform better compared to seven-year-old children in the sprint run (p = 0.11), standing long jump (p > 0.99) and shuttle run (p = 0.43), whereas they were better in all other disciplines compared to their younger peers. The average performance of boys was better than girls except for tapping at the age of 8 (p = 0.06). Differences in performance due to testing protocol and setting must be considered when test values from a first grade setting are compared to criterion-based benchmarks. In a classroom setting, younger children tended to have better results and older children tended to have worse outcomes when compared to their age group criterion reference values. Norm reference data are valid allowing comparison with other data generated by similar test protocols applied in a classroom setting.

  3. Cost-effectiveness analysis of a quantitative immunochemical test for colorectal cancer screening.

    PubMed

    Wilschut, Janneke A; Hol, Lieke; Dekker, Evelien; Jansen, Jan B; Van Leerdam, Monique E; Lansdorp-Vogelaar, Iris; Kuipers, Ernst J; Habbema, J Dik F; Van Ballegooijen, Marjolein

    2011-11-01

    Two European randomized trials (N = 30,000) compared guaiac fecal occult blood testing with quantitative fecal immunochemical testing (FIT) and showed better attendance rates and test characteristics for FIT. We aimed to identify the most cost-effective FIT cutoff level for referral to colonoscopy based on data from these trials and allowing for differences in screening ages. We used the validated MIcrosimulation SCreening ANalysis (MISCAN)-Colon microsimulation model to estimate costs and effects of different screening strategies for FIT cutoff levels of 50, 75, 100, 150, and 200 ng/mL hemoglobin. For each cutoff level, screening strategies were assessed with various age ranges and screening intervals. We assumed sufficient colonoscopy capacity for all strategies. At all cost levels, FIT screening was most effective with the 50 ng/mL cutoff level. The incremental cost-effectiveness ratio of biennial screening between ages 55 and 75 years using FIT at 50 ng/mL, for example, was 3900 euro per life year gained. Annual screening had an incremental cost-effectiveness ratio of 14,900 euro per life year gained, in combination with a wider age range (between ages 45 and 80 years). In the sensitivity analysis, 50 ng/mL remained the preferred cutoff level. FIT screening is more cost-effective at a cutoff level of 50 ng/mL than at higher cutoff levels. This supports the recommendation to use FIT at a cutoff level of 50 ng/mL, which is considerably lower than the values used in current practice. Copyright © 2011 AGA Institute. Published by Elsevier Inc. All rights reserved.

  4. Inter-laboratory Comparison of Three Earplug Fit-test Systems

    PubMed Central

    Byrne, David C.; Murphy, William J.; Krieg, Edward F.; Ghent, Robert M.; Michael, Kevin L.; Stefanson, Earl W.; Ahroon, William A.

    2017-01-01

    The National Institute for Occupational Safety and Health (NIOSH) sponsored tests of three earplug fit-test systems (NIOSH HPD Well-Fit™, Michael & Associates FitCheck, and Honeywell Safety Products VeriPRO®). Each system was compared to laboratory-based real-ear attenuation at threshold (REAT) measurements in a sound field according to ANSI/ASA S12.6-2008 at the NIOSH, Honeywell Safety Products, and Michael & Associates testing laboratories. An identical study was conducted independently at the U.S. Army Aeromedical Research Laboratory (USAARL), which provided their data for inclusion in this report. The Howard Leight Airsoft premolded earplug was tested with twenty subjects at each of the four participating laboratories. The occluded fit of the earplug was maintained during testing with a soundfield-based laboratory REAT system as well as all three headphone-based fit-test systems. The Michael & Associates lab had highest average A-weighted attenuations and smallest standard deviations. The NIOSH lab had the lowest average attenuations and the largest standard deviations. Differences in octave-band attenuations between each fit-test system and the American National Standards Institute (ANSI) sound field method were calculated (Attenfit-test - AttenANSI). A-weighted attenuations measured with FitCheck and HPD Well-Fit systems demonstrated approximately ±2 dB agreement with the ANSI sound field method, but A-weighted attenuations measured with the VeriPRO system underestimated the ANSI laboratory attenuations. For each of the fit-test systems, the average A-weighted attenuation across the four laboratories was not significantly greater than the average of the ANSI sound field method. Standard deviations for residual attenuation differences were about ±2 dB for FitCheck and HPD Well-Fit compared to ±4 dB for VeriPRO. Individual labs exhibited a range of agreement from less than a dB to as much as 9.4 dB difference with ANSI and REAT estimates. Factors such as

  5. WOODSTOVE DURABILITY TESTING PROTOCOL

    EPA Science Inventory

    The report discusses the development of an accelerated laboratory test to simulate in-home woodstove aging and degradation. nown as a stress test, the protocol determines the long-term durability of woodstove models in a 1- to 2-week time frame. wo avenues of research have been t...

  6. An approach to standardization of urine sediment analysis via suggestion of a common manual protocol.

    PubMed

    Ko, Dae-Hyun; Ji, Misuk; Kim, Sollip; Cho, Eun-Jung; Lee, Woochang; Yun, Yeo-Min; Chun, Sail; Min, Won-Ki

    2016-01-01

    The results of urine sediment analysis have been reported semiquantitatively. However, as recent guidelines recommend quantitative reporting of urine sediment, and with the development of automated urine sediment analyzers, there is an increasing need for quantitative analysis of urine sediment. Here, we developed a protocol for urine sediment analysis and quantified the results. Based on questionnaires, various reports, guidelines, and experimental results, we developed a protocol for urine sediment analysis. The results of this new protocol were compared with those obtained with a standardized chamber and an automated sediment analyzer. Reference intervals were also estimated using new protocol. We developed a protocol with centrifugation at 400 g for 5 min, with the average concentration factor of 30. The correlation between quantitative results of urine sediment analysis, the standardized chamber, and the automated sediment analyzer were generally good. The conversion factor derived from the new protocol showed a better fit with the results of manual count than the default conversion factor in the automated sediment analyzer. We developed a protocol for manual urine sediment analysis to quantitatively report the results. This protocol may provide a mean for standardization of urine sediment analysis.

  7. High School Students' Attitudes toward Fitness Testing

    ERIC Educational Resources Information Center

    Mercier, Kevin; Silverman, Stephen

    2014-01-01

    The purpose of this study was to investigate the attitudes of high school students toward fitness testing. An instrument containing 18 items and four factors measuring student's attitudes toward fitness testing: cognitive, affect-enjoyment, affect-feelings, and affect-teacher was completed by 524 boys and 675 girls (N = 1199). MANOVA indicated…

  8. CPM Test-Retest Reliability: "Standard" vs "Single Test-Stimulus" Protocols.

    PubMed

    Granovsky, Yelena; Miller-Barmak, Adi; Goldstein, Oren; Sprecher, Elliot; Yarnitsky, David

    2016-03-01

    Assessment of pain inhibitory mechanisms using conditioned pain modulation (CPM) is relevant clinically in prediction of pain and analgesic efficacy. Our objective is to provide necessary estimates of intersession CPM reliability, to enable transformation of the CPM paradigm into a clinical tool. Two cohorts of young healthy subjects (N = 65) participated in two dual-session studies. In Study I, a Bath-Thermode CPM protocol was used, with hot water immersion and contact heat as conditioning- and test-stimuli, respectively, in a classical parallel CPM design introducing test-stimulus first, and then the conditioning- and repeated test-stimuli in parallel. Study II consisted of two CPM protocols: 1) Two-Thermodes, one for each of the stimuli, in the same parallel design as above, and 2) single test-stimulus (STS) protocol with a single administration of a contact heat test-stimulus, partially overlapped in time by a remote shorter contact heat as conditioning stimulus. Test-retest reliability was assessed within 3-7 days. The STS-CPM had superior reliability intraclass correlation (ICC 2 ,: 1  = 0.59) over Bath-Thermode (ICC 2 ,: 1  = 0.34) or Two-Thermodes (ICC 2 ,: 1  = 0.21) protocols. The hand immersion conditioning pain had higher reliability than thermode pain (ICC 2 ,: 1  = 0.76 vs ICC 2 ,: 1  = 0.16). Conditioned test-stimulus pain scores were of good (ICC 2 ,: 1  = 0.62) or fair (ICC 2 ,: 1  = 0.43) reliability for the Bath-Thermode and the STS, respectively, but not for the Two-Thermodes protocol (ICC 2 ,: 1  = 0.20). The newly developed STS-CPM paradigm was more reliable than other CPM protocols tested here, and should be further investigated for its clinical relevance. It appears that large contact size of the conditioning-stimulus and use of single rather than dual test-stimulus pain contribute to augmentation of CPM reliability. © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e

  9. Effective Teaching Practices during Physical Fitness Testing

    ERIC Educational Resources Information Center

    Stewart, Amanda; Elliot, Steven; Boyce, B. Ann; Block, Martin E.

    2005-01-01

    Participation in fitness tests is among the most common memories many adults hold of physical education class. If students have a negative attitude towards fitness testing, they may be less likely to assess their own progress once they graduate. These negative attitudes often promote lifestyle choices that support participation in at-risk…

  10. Childhood Fitness and Academic Performance: An Investigation into the Effect of Aerobic Capacity on Academic Test Scores

    ERIC Educational Resources Information Center

    Hobbs, Mark

    2014-01-01

    The purpose of this quantitate ve study was to determine whether or not students in fifth grade who meet the healthy fitness zone (HFZ) for aerobic capacity on the fall 2013 FITNESSGRAM® Test scored higher on the math portion of the 2013 fall Measures of Academic Progress (MAP) test, than students that failed to reach the HFZ for aerobic capacity…

  11. An Evaluation of Protocol Enhancing Proxies and File Transport Protocols for Satellite Communication

    NASA Technical Reports Server (NTRS)

    Finch, Patrick Eugene; Sullivan, Donald; Ivancic, William D.

    2012-01-01

    NASA is utilizing Global Hawk aircraft in high-altitude, long-duration Earth science missions. Communications with the onboard research equipment and sensors (the science payload) is via Ku-Band radio utilizing satellites in geostationary orbits. All payload communications use standard Internet Protocols and routing, and much of the data to be transferred is comprised of very large files. The science community is interested in fully utilizing these communication links to retrieve data as quickly and reliably as possible. A test bed was developed at NASA Ames to evaluate modern transport protocols as well as Protocol Enhancing Proxies (PEPs) to determine what tools best fit the needs of the science community. This paper describes the test bed used, the protocols, the PEPs that were evaluated, the particular tests performed and the results and conclusions.

  12. Quantitative analysis of crystalline pharmaceuticals in powders and tablets by a pattern-fitting procedure using X-ray powder diffraction data.

    PubMed

    Yamamura, S; Momose, Y

    2001-01-16

    A pattern-fitting procedure for quantitative analysis of crystalline pharmaceuticals in solid dosage forms using X-ray powder diffraction data is described. This method is based on a procedure for pattern-fitting in crystal structure refinement, and observed X-ray scattering intensities were fitted to analytical expressions including some fitting parameters, i.e. scale factor, peak positions, peak widths and degree of preferred orientation of the crystallites. All fitting parameters were optimized by the non-linear least-squares procedure. Then the weight fraction of each component was determined from the optimized scale factors. In the present study, well-crystallized binary systems, zinc oxide-zinc sulfide (ZnO-ZnS) and salicylic acid-benzoic acid (SA-BA), were used as the samples. In analysis of the ZnO-ZnS system, the weight fraction of ZnO or ZnS could be determined quantitatively in the range of 5-95% in the case of both powders and tablets. In analysis of the SA-BA systems, the weight fraction of SA or BA could be determined quantitatively in the range of 20-80% in the case of both powders and tablets. Quantitative analysis applying this pattern-fitting procedure showed better reproducibility than other X-ray methods based on the linear or integral intensities of particular diffraction peaks. Analysis using this pattern-fitting procedure also has the advantage that the preferred orientation of the crystallites in solid dosage forms can be also determined in the course of quantitative analysis.

  13. Secondary School Students' Attitudes toward Fitness Testing

    ERIC Educational Resources Information Center

    Mercier, Kevin John

    2011-01-01

    The purpose of this investigation was to develop an instrument that has scores that are valid and reliable for measuring students' attitudes toward fitness testing. A second purpose of the study was to determine the attitudes of secondary students toward fitness testing. A review of literature, an elicitation study, and a pilot study were…

  14. Quantitative investigation of ligament strains during physical tests for sacroiliac joint pain using finite element analysis.

    PubMed

    Kim, Yoon Hyuk; Yao, Zhidong; Kim, Kyungsoo; Park, Won Man

    2014-06-01

    It may be assumed that the stability is affected when some ligaments are injured or loosened, and this joint instability causes sacroiliac joint pain. Several physical examinations have been used to diagnose sacroiliac pain and to isolate the source of the pain. However, more quantitative and objective information may be necessary to identify unstable or injured ligaments during these tests due to the lack of understanding of the quantitative relationship between the physical tests and the biomechanical parameters that may be related to pains in the sacroiliac joint and the surrounding ligaments. In this study, a three-dimensional finite element model of the sacroiliac joint was developed and the biomechanical conditions for six typical physical tests such as the compression test, distraction test, sacral apex pressure test, thigh thrust test, Patrick's test, and Gaenslen's test were modelled. The sacroiliac joint contact pressure and ligament strain were investigated for each test. The values of contact pressure and the combination of most highly strained ligaments differed markedly among the tests. Therefore, these findings in combination with the physical tests would be helpful to identify the pain source and to understand the pain mechanism. Moreover, the technology provided in this study might be a useful tool to evaluate the physical tests, to improve the present test protocols, or to develop a new physical test protocol. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Quantitative mouse brain phenotyping based on single and multispectral MR protocols

    PubMed Central

    Badea, Alexandra; Gewalt, Sally; Avants, Brian B.; Cook, James J.; Johnson, G. Allan

    2013-01-01

    Sophisticated image analysis methods have been developed for the human brain, but such tools still need to be adapted and optimized for quantitative small animal imaging. We propose a framework for quantitative anatomical phenotyping in mouse models of neurological and psychiatric conditions. The framework encompasses an atlas space, image acquisition protocols, and software tools to register images into this space. We show that a suite of segmentation tools (Avants, Epstein et al., 2008) designed for human neuroimaging can be incorporated into a pipeline for segmenting mouse brain images acquired with multispectral magnetic resonance imaging (MR) protocols. We present a flexible approach for segmenting such hyperimages, optimizing registration, and identifying optimal combinations of image channels for particular structures. Brain imaging with T1, T2* and T2 contrasts yielded accuracy in the range of 83% for hippocampus and caudate putamen (Hc and CPu), but only 54% in white matter tracts, and 44% for the ventricles. The addition of diffusion tensor parameter images improved accuracy for large gray matter structures (by >5%), white matter (10%), and ventricles (15%). The use of Markov random field segmentation further improved overall accuracy in the C57BL/6 strain by 6%; so Dice coefficients for Hc and CPu reached 93%, for white matter 79%, for ventricles 68%, and for substantia nigra 80%. We demonstrate the segmentation pipeline for the widely used C57BL/6 strain, and two test strains (BXD29, APP/TTA). This approach appears promising for characterizing temporal changes in mouse models of human neurological and psychiatric conditions, and may provide anatomical constraints for other preclinical imaging, e.g. fMRI and molecular imaging. This is the first demonstration that multiple MR imaging modalities combined with multivariate segmentation methods lead to significant improvements in anatomical segmentation in the mouse brain. PMID:22836174

  16. Application of the IAP cardiovascular fitness test protocol for Austromars candidate screening

    NASA Astrophysics Data System (ADS)

    Grasser, E. K.; Goswami, N.; Jantscher, A.; Roessler, A.; Vrecko, K.; Groemer, G.; Hinghofer-Szalkay, H.

    2007-10-01

    Rationale: The purpose of our research was to test for cardiovascular stability within 16 Austromars candidates, and to determine hemodynamic variables and hormones in a presyncopal state as evoked by a specific test protocol. Procedures and methods: We used a graded orthostatic stress (GOS) paradigm consisting of head-up tilt (HUT) combined with lower body negative pressure (LBNP) up to a presyncopal end-point on 15 males and one healthy female. Hemodynamic parameters were monitored and venous blood samples taken. Results: From supine control to presyncope, mean standing time was 12.3 ± 1.2 min, heart rate (HR) increased by 68 ± 12% (p < 0.0001) and thoracic impedance (TI) rose by 12 ± 1% (p < 0.0001), whereas following parameters decreased: stroke volume index (SI) 44 ± 4% (p < 0.0001), systolic pressure (SBP) 26 ± 3% (p < 0.0001), diastolic pressure (DBP) 16 ± 5% (p = 0.004), mean arterial blood pressure (MAP) 19 ± 3% (p < 0.0001), pulse pressure 41 ± 8% (p = 0.0003) and total peripheral resistance index (TPRI) 11 ± 5% (p = 0.03). Heart rate and blood pressure variabilities decreased together with pulse pressure. Plasma volume decreased by 11 ± 2% (p = 0.0004). Plasma norepinephrine (NE) increased by 86 ± 16% (p = 0.0001), epinephrine (E) by 460 ± 266% (p = 0.06), cortisol by 10 ± 6% (p = 0.02), plasma renin activity by 147 ± 26% (p = 0.002) and aldosterone by 24 ± 21% (p = 0.2). Conclusion: Our combined HUT- graded LBNP paradigm is useful to study CV regulation and hormonal responses under severe stress conditions.

  17. Numerical simulation of a relaxation test designed to fit a quasi-linear viscoelastic model for temporomandibular joint discs.

    PubMed

    Commisso, Maria S; Martínez-Reina, Javier; Mayo, Juana; Domínguez, Jaime

    2013-02-01

    The main objectives of this work are: (a) to introduce an algorithm for adjusting the quasi-linear viscoelastic model to fit a material using a stress relaxation test and (b) to validate a protocol for performing such tests in temporomandibular joint discs. This algorithm is intended for fitting the Prony series coefficients and the hyperelastic constants of the quasi-linear viscoelastic model by considering that the relaxation test is performed with an initial ramp loading at a certain rate. This algorithm was validated before being applied to achieve the second objective. Generally, the complete three-dimensional formulation of the quasi-linear viscoelastic model is very complex. Therefore, it is necessary to design an experimental test to ensure a simple stress state, such as uniaxial compression to facilitate obtaining the viscoelastic properties. This work provides some recommendations about the experimental setup, which are important to follow, as an inadequate setup could produce a stress state far from uniaxial, thus, distorting the material constants determined from the experiment. The test considered is a stress relaxation test using unconfined compression performed in cylindrical specimens extracted from temporomandibular joint discs. To validate the experimental protocol, the test was numerically simulated using finite-element modelling. The disc was arbitrarily assigned a set of quasi-linear viscoelastic constants (c1) in the finite-element model. Another set of constants (c2) was obtained by fitting the results of the simulated test with the proposed algorithm. The deviation of constants c2 from constants c1 measures how far the stresses are from the uniaxial state. The effects of the following features of the experimental setup on this deviation have been analysed: (a) the friction coefficient between the compression plates and the specimen (which should be as low as possible); (b) the portion of the specimen glued to the compression plates (smaller

  18. Adolescents' Interest and Performances in Aerobic Fitness Testing

    ERIC Educational Resources Information Center

    Zhu, Xihe; Chen, Senlin; Parrott, James

    2014-01-01

    This study examined adolescents' interest in aerobic fitness testing and its relation to the test performances. Adolescents (N = 356) from three middle schools participated in the study. The participants took two aerobic fitness tests: the Progressive Aerobic Cardiovascular Endurance Run (PACER) and One-Mile Run (1MR) with a two-day interval, and…

  19. Why are some people more fit than others? Correlates and determinants of cardiorespiratory fitness in adults: protocol for a systematic review.

    PubMed

    Perumal, Nita; Mensink, Gert B M; Keil, Thomas; Finger, Jonas David

    2017-05-18

    Cardiorespiratory fitness (CRF) is a physical condition that is now well established as a predictor of numerous adverse health outcomes, independent of physical activity levels. In order to be able to improve CRF at the population level and to develop effective interventions and public health programmes, it is important to understand why some people are more fit than others. Therefore, the primary aim of the systematic review described in this protocol is to examine individual and interpersonal factors that are correlated with or determine CRF among adults. The review will focus on quantitative studies that investigate any personal and interpersonal correlates and/or determinants of objectively measured CRF among the general, non-symptomatic, non-institutionalized adult population (aged 18-65 years) worldwide. The databases MEDLINE, Embase, and Cochrane Library will be searched to identify all relevant published journal articles, and Google Scholar and Scopus will be searched for grey literature. Studies where CRF is not an outcome variable and experimental studies where participants specifically receive a fitness intervention that increases CRF will be excluded. For each study, data extracted will include, among other variables, study characteristics, methodology for selecting participants into the study as well as the participants' demographic characteristics, types of correlates and determinants of CRF investigated and their measurement methods, the objective measure of CRF used and its measurement method and validity, and the main reported results on the association between the correlates or determinants and CRF. In addition, observational studies will be assessed for methodological quality and risk of bias using a customized version of the Quality Assessment Tool for Observational Cohort and Cross-Sectional Studies by the National Heart, Lung, and Blood Institute. Experimental studies will be assessed using the 27-item Downs and Black "Checklist for Measuring

  20. ENVIRONMENTAL TECHNOLOGY VERIFICATION TEST PROTOCOL, GENERAL VENTILATION FILTERS

    EPA Science Inventory

    The Environmental Technology Verification Test Protocol, General Ventilation Filters provides guidance for verification tests.

    Reference is made in the protocol to the ASHRAE 52.2P "Method of Testing General Ventilation Air-cleaning Devices for Removal Efficiency by P...

  1. Providing Quantitative Information and a Nudge to Undergo Stool Testing in a Colorectal Cancer Screening Decision Aid: A Randomized Clinical Trial.

    PubMed

    Schwartz, Peter H; Perkins, Susan M; Schmidt, Karen K; Muriello, Paul F; Althouse, Sandra; Rawl, Susan M

    2017-08-01

    Guidelines recommend that patient decision aids should provide quantitative information about probabilities of potential outcomes, but the impact of this information is unknown. Behavioral economics suggests that patients confused by quantitative information could benefit from a "nudge" towards one option. We conducted a pilot randomized trial to estimate the effect sizes of presenting quantitative information and a nudge. Primary care patients (n = 213) eligible for colorectal cancer screening viewed basic screening information and were randomized to view (a) quantitative information (quantitative module), (b) a nudge towards stool testing with the fecal immunochemical test (FIT) (nudge module), (c) neither a nor b, or (d) both a and b. Outcome measures were perceived colorectal cancer risk, screening intent, preferred test, and decision conflict, measured before and after viewing the decision aid, and screening behavior at 6 months. Patients viewing the quantitative module were more likely to be screened than those who did not ( P = 0.012). Patients viewing the nudge module had a greater increase in perceived colorectal cancer risk than those who did not ( P = 0.041). Those viewing the quantitative module had a smaller increase in perceived risk than those who did not ( P = 0.046), and the effect was moderated by numeracy. Among patients with high numeracy who did not view the nudge module, those who viewed the quantitative module had a greater increase in intent to undergo FIT ( P = 0.028) than did those who did not. The limitations of this study were the limited sample size and single healthcare system. Adding quantitative information to a decision aid increased uptake of colorectal cancer screening, while adding a nudge to undergo FIT did not increase uptake. Further research on quantitative information in decision aids is warranted.

  2. Physical employment standard for Canadian wildland firefighters: examining test-retest reliability and the impact of familiarisation and physical fitness training.

    PubMed

    Gumieniak, Robert J; Gledhill, Norman; Jamnik, Veronica K

    2018-05-04

    To assess the impact of repeat performances (familiarisation) plus exercise training on completion time for the Ontario Wildland Firefighter (WFF) Fitness Test circuit (WFX-FIT), normally active general population participants (n = 145) were familiarised to the protocol then randomised into (i) exercise training, (ii) circuit only weekly performances or (iii) controls. At Baseline, the WFX-FIT pass rate for all groups combined was 11% for females and 73% for males, indicating that the Ontario WFX-FIT standard had a possible adverse impact on females. Following test familiarisation, mean circuit completion times improved by 11.9% and 10.2% for females and males, respectively. There were significant improvements in completion time for females (19.8%) and males (16.9%) who trained, plus females (12.2%) and males (9.8%) who performed the circuit only, while control participants were unchanged. Post training, the pass rate of the training group was 80% for females and 100% for males. Practitioner Summary: This paper details the impact of familiarisation plus exercise training as accommodation to mitigate potential adverse impact on initial attack wildland firefighter test performance. The results underscore the importance of test familiarisation opportunities and physical fitness training programmes that are specific to the demands of the job.

  3. Portable fixture facilitates pressure testing of instrumentation fittings

    NASA Technical Reports Server (NTRS)

    Olson, G. A.

    1967-01-01

    Portable fixture facilitates pressure testing to detect possible leaks in instrumentation fittings mounted on tank bulkheads. It uses a vacuum cup which seals a pressure regulator adapter around one side of the fitting to be pressure tested. Leakage is detected with a gas sniffer.

  4. Inappropriate Practices in Fitness Testing and Reporting: Alternative Strategies

    ERIC Educational Resources Information Center

    Zhu, Xihe; Davis, Summer; Kirk, T. Nicole; Haegele, Justin A.; Knott, Stephen E.

    2018-01-01

    Fitness education is becoming an integrated component for many physical education programs. As such, many physical educators conduct health-related fitness tests on a regular basis. Some states even mandate certain types of physical fitness tests to be administered and reported annually or by semester. Yet, inappropriate practices have been…

  5. The Brockport Physical Fitness Test Training Manual. [Project Target].

    ERIC Educational Resources Information Center

    Winnick, Joseph P.; Short, Francis X., Ed.

    This training manual presents information on the Brockport Physical Fitness Test (BPFT), a criterion-referenced fitness test for children and adolescents with disabilities. The first chapter of the test training manual includes information dealing with health-related criterion-referenced testing, the interaction between physical activity and…

  6. A 12-Week Vigorous Exercise Protocol in a Healthy Group of Persons over 65: Study of Physical Function by means of the Senior Fitness Test

    PubMed Central

    Todde, Francesco; Melis, Franco; Mura, Roberto; Pau, Massimiliano; Fois, Francesco; Magnani, Sara; Ibba, Gianfranco; Crisafulli, Antonio; Tocco, Filippo

    2016-01-01

    The aim of this study was to assess the effects of vigorous exercise on functional abilities by means of a Senior Fitness Test (SFT) in a group of elderly adults. Twenty healthy and inactive people performed vigorous exercise (VE: 12 men and 8 women, aged 69.6 ± 3.9 years). At the beginning of the study (T0) and after 3 months (T1), each subject's functional ability was tested for muscular strength, agility, cardiovascular fitness, flexibility, and balance. The VE was designed with continuous and interval exercise involving large muscle activities. Functional exercises were performed between 60% and 84% of heart rate reserve (HRR) for a duration of 65 minutes. Five out of the 6 SFTs performed were found significantly improved: Chair Stand (T0 12.4 ± 2.4, T1 13.5 ± 2.6, p < 0.01), Arm Curl (T0 14.2 ± 3.6, T1 16.6 ± 3.6, p < 0.01), 2 min step (T0 98.2 ± 15.7, T1 108.9 ± 16.2, p < 0.01), Chair Sit-and-Reach (T0 −9.9 ± 7.7 cm, T1 1.7 ± 6.3 cm, p < 0.01), and Back Scratch (T0 −15.8 ± 10.9 cm, T1 −8.4 ± 13.1 cm, p < 0.01). Our results suggest that a high intensity protocol and functional exercises can improve functional mobility and muscle endurance in those over 65 years of age. SFTs are an effective method for assessing improvements in the functional capacity of elderly adults. PMID:27243035

  7. 1958-2008: 50 years of youth fitness tests in the United States.

    PubMed

    Morrow, James R; Zhu, Weimo; Franks, B Don; Meredith, Marilu D; Spain, Christine

    2009-03-01

    The AAHPER Youth Fitness Test, the first U.S. national fitness test, was published 50 years ago. The seminal work of Krause and Hirschland influenced the fitness world and continues to do so today. Important youth fitness test initiatives in the last half century are summarized. Key elements leading to continued interest in youth fitness testing at the start of the 21st century include (a) concerns about children and youth fitness levels, (b) AAHPER(D)-led youth fitness battery development, (c) differentiation between performance-related and health-related fitness testing, (d) the numerous youth fitness tests developed, (e) collaborative discussions on development and adoption of a unified national youth fitness battery, (f) computerization of youth fitness test results, (g) differentiation between norm-referenced and criterion-referenced evaluation of student results, and (h) concern about youth fitness levels (again, but with a focus on health). We have come full circle on youth fitness interests. This article summarizes the key youth fitness tests in the second half of the 20th century and projects future considerations.

  8. Quantitative image feature variability amongst CT scanners with a controlled scan protocol

    NASA Astrophysics Data System (ADS)

    Ger, Rachel B.; Zhou, Shouhao; Chi, Pai-Chun Melinda; Goff, David L.; Zhang, Lifei; Lee, Hannah J.; Fuller, Clifton D.; Howell, Rebecca M.; Li, Heng; Stafford, R. Jason; Court, Laurence E.; Mackin, Dennis S.

    2018-02-01

    Radiomics studies often analyze patient computed tomography (CT) images acquired from different CT scanners. This may result in differences in imaging parameters, e.g. different manufacturers, different acquisition protocols, etc. However, quantifiable differences in radiomics features can occur based on acquisition parameters. A controlled protocol may allow for minimization of these effects, thus allowing for larger patient cohorts from many different CT scanners. In order to test radiomics feature variability across different CT scanners a radiomics phantom was developed with six different cartridges encased in high density polystyrene. A harmonized protocol was developed to control for tube voltage, tube current, scan type, pitch, CTDIvol, convolution kernel, display field of view, and slice thickness across different manufacturers. The radiomics phantom was imaged on 18 scanners using the control protocol. A linear mixed effects model was created to assess the impact of inter-scanner variability with decomposition of feature variation between scanners and cartridge materials. The inter-scanner variability was compared to the residual variability (the unexplained variability) and to the inter-patient variability using two different patient cohorts. The patient cohorts consisted of 20 non-small cell lung cancer (NSCLC) and 30 head and neck squamous cell carcinoma (HNSCC) patients. The inter-scanner standard deviation was at least half of the residual standard deviation for 36 of 49 quantitative image features. The ratio of inter-scanner to patient coefficient of variation was above 0.2 for 22 and 28 of the 49 features for NSCLC and HNSCC patients, respectively. Inter-scanner variability was a significant factor compared to patient variation in this small study for many of the features. Further analysis with a larger cohort will allow more thorough analysis with additional variables in the model to truly isolate the interscanner difference.

  9. High School Physical Education Teachers' Attitudes and Use of Fitness Tests

    ERIC Educational Resources Information Center

    Mercier, Kevin; Phillips, Sharon; Silverman, Stephen

    2016-01-01

    Recommendations for using and implementing fitness tests have been extensively researched and teachers' attitudes toward fitness tests are beginning to be studied. Less understood is how high school teachers use fitness tests and the role their attitudes toward fitness tests affect students' attitudes toward physical activity. The purpose of this…

  10. Assessing fitness to stand trial: the utility of the Fitness Interview Test (revised edition).

    PubMed

    Zapf, P A; Roesch, R; Viljoen, J L

    2001-06-01

    In Canada most evaluations of fitness to stand trial are conducted on an inpatient basis. This costs time and money, and deprives those defendants remanded for evaluation of liberty. This research assessed the predictive efficiency of the Fitness Interview Test, revised edition (FIT) as a screening instrument for fitness to stand trial. We compared decisions about fitness to stand trial, based on the FIT, with the results of institution-based evaluations for 2 samples of men remanded for inpatient fitness assessments. The FIT demonstrates excellent utility as a screening instrument. The FIT shows good sensitivity and negative predictive power, which suggests that it can reliably screen those individuals who are clearly fit to stand trial, before they are remanded to an inpatient facility for a fitness assessment. We discuss the implications for evaluating fitness to stand trial, particularly in terms of the need for community-based alternatives to traditional forensic assessments.

  11. Fit Assessment of N95 Filtering-Facepiece Respirators in the U.S. Centers for Disease Control and Prevention Strategic National Stockpile.

    PubMed

    Bergman, Michael; Zhuang, Ziqing; Brochu, Elizabeth; Palmiero, Andrew

    National Institute for Occupational Safety and Health (NIOSH)-approved N95 filtering-facepiece respirators (FFR) are currently stockpiled by the U.S. Centers for Disease Control and Prevention (CDC) for emergency deployment to healthcare facilities in the event of a widespread emergency such as an influenza pandemic. This study assessed the fit of N95 FFRs purchased for the CDC Strategic National Stockpile. The study addresses the question of whether the fit achieved by specific respirator sizes relates to facial size categories as defined by two NIOSH fit test panels. Fit test data were analyzed from 229 test subjects who performed a nine-donning fit test on seven N95 FFR models using a quantitative fit test protocol. An initial respirator model selection process was used to determine if the subject could achieve an adequate fit on a particular model; subjects then tested the adequately fitting model for the nine-donning fit test. Only data for models which provided an adequate initial fit (through the model selection process) for a subject were analyzed for this study. For the nine-donning fit test, six of the seven respirator models accommodated the fit of subjects (as indicated by geometric mean fit factor > 100) for not only the intended NIOSH bivariate and PCA panel sizes corresponding to the respirator size, but also for other panel sizes which were tested for each model. The model which showed poor performance may not be accurately represented because only two subjects passed the initial selection criteria to use this model. Findings are supportive of the current selection of facial dimensions for the new NIOSH panels. The various FFR models selected for the CDC Strategic National Stockpile provide a range of sizing options to fit a variety of facial sizes.

  12. Fit Assessment of N95 Filtering-Facepiece Respirators in the U.S. Centers for Disease Control and Prevention Strategic National Stockpile

    PubMed Central

    Bergman, Michael; Zhuang, Ziqing; Brochu, Elizabeth; Palmiero, Andrew

    2016-01-01

    National Institute for Occupational Safety and Health (NIOSH)-approved N95 filtering-facepiece respirators (FFR) are currently stockpiled by the U.S. Centers for Disease Control and Prevention (CDC) for emergency deployment to healthcare facilities in the event of a widespread emergency such as an influenza pandemic. This study assessed the fit of N95 FFRs purchased for the CDC Strategic National Stockpile. The study addresses the question of whether the fit achieved by specific respirator sizes relates to facial size categories as defined by two NIOSH fit test panels. Fit test data were analyzed from 229 test subjects who performed a nine-donning fit test on seven N95 FFR models using a quantitative fit test protocol. An initial respirator model selection process was used to determine if the subject could achieve an adequate fit on a particular model; subjects then tested the adequately fitting model for the nine-donning fit test. Only data for models which provided an adequate initial fit (through the model selection process) for a subject were analyzed for this study. For the nine-donning fit test, six of the seven respirator models accommodated the fit of subjects (as indicated by geometric mean fit factor > 100) for not only the intended NIOSH bivariate and PCA panel sizes corresponding to the respirator size, but also for other panel sizes which were tested for each model. The model which showed poor performance may not be accurately represented because only two subjects passed the initial selection criteria to use this model. Findings are supportive of the current selection of facial dimensions for the new NIOSH panels. The various FFR models selected for the CDC Strategic National Stockpile provide a range of sizing options to fit a variety of facial sizes. PMID:26877587

  13. Mn/ROAD testing protocols : vol. 1

    DOT National Transportation Integrated Search

    1997-12-01

    This report presents a series of testing protocols used at the Minnesota Road Research Project (Mn/ROAD), the Minnesota Department of Transportation's (Mn/DOT) pavement testing facility. This report helps establish a history of the tests conducted an...

  14. Construct Validity of Physical Fitness Tests

    DTIC Science & Technology

    2011-02-03

    Medicine and Science in Sports and Exercise , 21, 319-324. *Fleishman, E. A. (1964). The structure and measurement of physical fitness. Englewood Cliffs...Quarterly for Exercise and Sport, 64, 256-273. *McCloy, E. (1935). Factor analysis methods in the measurement of physical abilities. Research Quarterly...Research Quarterly, 34, 525. Physical Fitness Test Validity 23 Powers, S. K., & Howley, E. T. (1990). Exercise physiology: Theory and application to

  15. Fitness Testing: The Pleasure and Pain of It

    ERIC Educational Resources Information Center

    Garrett, Robyne; Wrench, Alison

    2008-01-01

    The obesity crisis is a discourse that has established common-sense understandings that all young people are less active and fit than previous generations. Unquestioning acceptance of the links between fitness and obesity in turn leads to unproblematic fitness testing of young people. This research investigated the personal and embodied…

  16. A Lasting Impression: A Pedagogical Perspective on Youth Fitness Testing

    ERIC Educational Resources Information Center

    Silverman, Stephen; Keating, Xiaofen Deng; Phillips, Sharon R.

    2008-01-01

    This article addresses ways in which fitness tests can be used positively in physical education. We take the position throughout the article that fitness tests should be used as formative evaluation to further educational goals. We begin by discussing the different ways in which adults and children use fitness tests. The next section, the heart of…

  17. Prevalence and correlates of physical fitness testing in U.S. schools--2000.

    PubMed

    Morrow, James R; Fulton, Janet E; Brener, Nancy D; Kohl, Harold W

    2008-06-01

    Because of the perceived lack of youth physical fitness and/or concerns for increased obesity, physical education teachers are interested in youth fitness and physical activity levels. Statewide mandates are being developed that require school-based teachers to complete physical fitness testing. Data from the nationally representative School Health Policies and Programs Study 2000 were analyzed to investigate the prevalence of fitness testing and the professional characteristics of fitness test users. Data were collected with teachers of either randomly selected classes in elementary schools and randomly selected required physical education courses in middle/junior high and senior high schools (N = 1,564). The prevalence of fitness test use is 65% across all school levels. Variables associated with physical fitness test usage were professionally oriented. Results showed that teachers in secondary schools (odds ratio [OR] = 2.25, 95% confidence interval [CI] = I.18-4.27), those with degrees in physical education/kinesiology-related disciplines (OR = 2.01, 95% CI = 1.11-3.63), and those who had completed staff development on physical fitness testing (OR = 3.22, 95% CI = 1.86-5.60) were more likely than respondents without these characteristics to engage in physical fitness testing. Results changed little when separate analyses were conducted for classes/courses in districts requiring versus not requiring fitness testing. Financial variables, including fitness-oriented facilities available, metropolitan location, and discretionary expenditures per student, were not associated with fitness test use. Results provided national prevalence of school-based physical fitness testing use in the U. S. and conveyed information about those who currently use physical fitness tests.

  18. Fitness Testing: How Do Students Make Sense of the Gender Disparities?

    ERIC Educational Resources Information Center

    Domangue, Elizabeth A.; Solmon, Melinda A.

    2012-01-01

    The ways in which students make sense of the gendered fitness expectations found in a norm-referenced fitness testing program (i.e. President's challenge physical fitness test) were the focus of this study. Participants were 18 fifth grade students who completed fitness tests in their physical education classes. They were interviewed using a…

  19. Assessment of Person Fit for Mixed-Format Tests

    ERIC Educational Resources Information Center

    Sinharay, Sandip

    2015-01-01

    Person-fit assessment may help the researcher to obtain additional information regarding the answering behavior of persons. Although several researchers examined person fit, there is a lack of research on person-fit assessment for mixed-format tests. In this article, the lz statistic and the ?2 statistic, both of which have been used for tests…

  20. A model based security testing method for protocol implementation.

    PubMed

    Fu, Yu Long; Xin, Xiao Long

    2014-01-01

    The security of protocol implementation is important and hard to be verified. Since the penetration testing is usually based on the experience of the security tester and the specific protocol specifications, a formal and automatic verification method is always required. In this paper, we propose an extended model of IOLTS to describe the legal roles and intruders of security protocol implementations, and then combine them together to generate the suitable test cases to verify the security of protocol implementation.

  1. Kansas Adapted/Special Physical Education Test Manual. Health Related Fitness and Psychomotor Testing.

    ERIC Educational Resources Information Center

    Johnson, Robert E.; Lavay, Barry

    This manual was developed to address the need for health-related physical fitness testing of children with special needs. The first section defines the components of health-related physical fitness which consist of: (1)abdominal strength and endurance measured by a sit-up test; (2) flexibility, measured by a sit and reach test; (3) upper body…

  2. GENERIC VERIFICATION PROTOCOL: DISTRIBUTED GENERATION AND COMBINED HEAT AND POWER FIELD TESTING PROTOCOL

    EPA Science Inventory

    This report is a generic verification protocol by which EPA’s Environmental Technology Verification program tests newly developed equipment for distributed generation of electric power, usually micro-turbine generators and internal combustion engine generators. The protocol will ...

  3. Physical Fitness Index for Assess Fitness Speed Among Army Reserve Officer Training Unit Cadet in Malaysia

    NASA Astrophysics Data System (ADS)

    Rustam, Shahrulfadly; Kassim, Mohar

    2018-05-01

    The aim of this study is to develop physical fitness index (PFI) for physical fitness among Army Reserve Officer Training Unit Cadet Malaysia. This study use 30 meter speed run as a physical fitness test battery to develop physical fitness index (PFI) and to evaluate the subject fitness speed. 212 male respondent (N=212) was selected in this study including Army Reserve Officer Training Unit Cadet of National Defence University of Malaysia. 30 meter sprint was used as a instrument for this study. The methodology will be adopted for this study is quantitative research in the form of a quasi-experiment. Quasi-experimental methods is used to measure and evaluate the level of physical fitness and develop Physical Fitness Index especially in speed. The design of this study is quasi-experimental study design with pre-test and post-test. The study design is quasi-experimental research design in which the data is obtained through the practical test in the field. The data were analysed by using the SPSS software version 20 to calculate the mean, standard deviation and t-test for develop physical fitness index (PFI) and to evaluate the fitness speed level for Army Reserve Officers Training Unit Cadet Malaysia. The findings showed mean and standard deviation for develope physical fitness index is (M=4.84) and (SD=0.48). The t-test for evaluate fitness level in speed for pre-test and post-test is significantly difference (p ≤ 0.05). The implication at this study is that the develope of standard physical fitness index is able to identify the level of physical fitness among Army Reserve Officer Training Unit Cadet Malaysia.

  4. A Model Based Security Testing Method for Protocol Implementation

    PubMed Central

    Fu, Yu Long; Xin, Xiao Long

    2014-01-01

    The security of protocol implementation is important and hard to be verified. Since the penetration testing is usually based on the experience of the security tester and the specific protocol specifications, a formal and automatic verification method is always required. In this paper, we propose an extended model of IOLTS to describe the legal roles and intruders of security protocol implementations, and then combine them together to generate the suitable test cases to verify the security of protocol implementation. PMID:25105163

  5. 1958-2008: 50 Years of Youth Fitness Tests in the United States

    ERIC Educational Resources Information Center

    Morrow, James R., Jr.; Zhu, Weimo; Franks, B. Don; Meredith, Marilu D.; Spain, Christine

    2009-01-01

    The AAHPER Youth Fitness Test, the first U.S. national fitness test, was published 50 years ago. The seminal work of Krause and Hirschland influenced the fitness world and continues to do so today. Important youth fitness test initiatives in the last half century are summarized. Key elements leading to continued interest in youth fitness testing…

  6. The Robinson Protocol: a treadmill anaerobic performance test.

    PubMed

    Robinson, Ellyn M; Graham, Louise B; Headley, Samuel A

    2004-08-01

    The current investigation was designed to further examine the reliability of the Robinson protocol, which is a run-to-exhaustion treadmill test. Robinson (10) originally examined this protocol with 5 subjects. The significance of the initial exploratory study was the impetus for expanding the study to examine the reliability of the protocol with a larger sample. Fifteen male subjects participated in 3 trial runs on the treadmill. The first trial was a modified McConnell (7) test to determine the aerobic capacity of each subject. The second and third trials were identical Robinson protocols (10). The first trial run mean, in seconds (262.04 +/- 74.50), was not significantly different from the second trial run mean (257.30 +/- 72.65), p = 0.526 (2 tailed). As expected, trial 1 and trial 2 were highly correlated (intraclass) (r = 0.927, p < 0.001). These results provide additional support for the hypothesis that the Robinson protocol with a greater subject pool is a reliable protocol that can be used in research studies interested in examining various physiological interventions or anaerobic training.

  7. Extra-Vehicular Activity (EVA) glove evaluation test protocol

    NASA Technical Reports Server (NTRS)

    Hinman-Sweeney, E. M.

    1994-01-01

    One of the most critical components of a space suit is the gloves, yet gloves have traditionally presented significant design challenges. With continued efforts at glove development, a method for evaluating glove performance is needed. This paper presents a pressure-glove evaluation protocol. A description of this evaluation protocol, and its development is provided. The protocol allows comparison of one glove design to another, or any one design to bare-handed performance. Gloves for higher pressure suits may be evaluated at current and future design pressures to drive out differences in performance due to pressure effects. Using this protocol, gloves may be evaluated during design to drive out design problems and determine areas for improvement, or fully mature designs may be evaluated with respect to mission requirements. Several different test configurations are presented to handle these cases. This protocol was run on a prototype glove. The prototype was evaluated at two operating pressures and in the unpressurized state, with results compared to bare-handed performance. Results and analysis from this test series are provided, as is a description of the configuration used for this test.

  8. Testing goodness of fit in regression: a general approach for specified alternatives.

    PubMed

    Solari, Aldo; le Cessie, Saskia; Goeman, Jelle J

    2012-12-10

    When fitting generalized linear models or the Cox proportional hazards model, it is important to have tools to test for lack of fit. Because lack of fit comes in all shapes and sizes, distinguishing among different types of lack of fit is of practical importance. We argue that an adequate diagnosis of lack of fit requires a specified alternative model. Such specification identifies the type of lack of fit the test is directed against so that if we reject the null hypothesis, we know the direction of the departure from the model. The goodness-of-fit approach of this paper allows to treat different types of lack of fit within a unified general framework and to consider many existing tests as special cases. Connections with penalized likelihood and random effects are discussed, and the application of the proposed approach is illustrated with medical examples. Tailored functions for goodness-of-fit testing have been implemented in the R package global test. Copyright © 2012 John Wiley & Sons, Ltd.

  9. Manitoba Physical Fitness Performance Test Manual and Fitness Objectives for Manitoba Youth 5-18 Years of Age.

    ERIC Educational Resources Information Center

    Manitoba Dept. of Education, Winnipeg.

    The physical fitness and lifestyle of Canadian school children has been deteriorating in recent years. The main objectives of physical education are directed toward the development of physical fitness and a positive lifestyle. This manual provides an opportunity for measuring the components of physical fitness. Physical fitness testing involves…

  10. 16 CFR 1210.4 - Test protocol.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... live within the United States. (4) The age and sex distribution of each 100-child panel shall be: (i... recorded for each child in the 100-child test panel: (1) Sex (male or female). (2) Date of birth (month... STANDARD FOR CIGARETTE LIGHTERS Requirements for Child Resistance § 1210.4 Test protocol. (a) Child test...

  11. 16 CFR 1210.4 - Test protocol.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... live within the United States. (4) The age and sex distribution of each 100-child panel shall be: (i... recorded for each child in the 100-child test panel: (1) Sex (male or female). (2) Date of birth (month... STANDARD FOR CIGARETTE LIGHTERS Requirements for Child Resistance § 1210.4 Test protocol. (a) Child test...

  12. 16 CFR 1212.4 - Test protocol.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...) The children for the test panel shall live within the United States. (4) The age and sex distribution... child in the 100-child test panel: (1) Sex (male or female). (2) Date of birth (month, day, year). (3... STANDARD FOR MULTI-PURPOSE LIGHTERS Requirements for Child-Resistance § 1212.4 Test protocol. (a) Child...

  13. 16 CFR 1212.4 - Test protocol.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) The children for the test panel shall live within the United States. (4) The age and sex distribution... child in the 100-child test panel: (1) Sex (male or female). (2) Date of birth (month, day, year). (3... STANDARD FOR MULTI-PURPOSE LIGHTERS Requirements for Child-Resistance § 1212.4 Test protocol. (a) Child...

  14. Task-technology fit of video telehealth for nurses in an outpatient clinic setting.

    PubMed

    Cady, Rhonda G; Finkelstein, Stanley M

    2014-07-01

    Incorporating telehealth into outpatient care delivery supports management of consumer health between clinic visits. Task-technology fit is a framework for understanding how technology helps and/or hinders a person during work processes. Evaluating the task-technology fit of video telehealth for personnel working in a pediatric outpatient clinic and providing care between clinic visits ensures the information provided matches the information needed to support work processes. The workflow of advanced practice registered nurse (APRN) care coordination provided via telephone and video telehealth was described and measured using a mixed-methods workflow analysis protocol that incorporated cognitive ethnography and time-motion study. Qualitative and quantitative results were merged and analyzed within the task-technology fit framework to determine the workflow fit of video telehealth for APRN care coordination. Incorporating video telehealth into APRN care coordination workflow provided visual information unavailable during telephone interactions. Despite additional tasks and interactions needed to obtain the visual information, APRN workflow efficiency, as measured by time, was not significantly changed. Analyzed within the task-technology fit framework, the increased visual information afforded by video telehealth supported the assessment and diagnostic information needs of the APRN. Telehealth must provide the right information to the right clinician at the right time. Evaluating task-technology fit using a mixed-methods protocol ensured rigorous analysis of fit within work processes and identified workflows that benefit most from the technology.

  15. A quantitative telomeric chromatin isolation protocol identifies different telomeric states

    NASA Astrophysics Data System (ADS)

    Grolimund, Larissa; Aeby, Eric; Hamelin, Romain; Armand, Florence; Chiappe, Diego; Moniatte, Marc; Lingner, Joachim

    2013-11-01

    Telomere composition changes during tumourigenesis, aging and in telomere syndromes in a poorly defined manner. Here we develop a quantitative telomeric chromatin isolation protocol (QTIP) for human cells, in which chromatin is cross-linked, immunopurified and analysed by mass spectrometry. QTIP involves stable isotope labelling by amino acids in cell culture (SILAC) to compare and identify quantitative differences in telomere protein composition of cells from various states. With QTIP, we specifically enrich telomeric DNA and all shelterin components. We validate the method characterizing changes at dysfunctional telomeres, and identify and validate known, as well as novel telomere-associated polypeptides including all THO subunits, SMCHD1 and LRIF1. We apply QTIP to long and short telomeres and detect increased density of SMCHD1 and LRIF1 and increased association of the shelterins TRF1, TIN2, TPP1 and POT1 with long telomeres. Our results validate QTIP to study telomeric states during normal development and in disease.

  16. Qualitative and quantitative evaluation of some vocal function parameters following fitting of a prosthesis.

    PubMed

    Cavalot, A L; Palonta, F; Preti, G; Nazionale, G; Ricci, E; Vione, N; Albera, R; Cortesina, G

    2001-12-01

    The insertion of a prosthesis and restoration with pectoralis major myocutaneous flaps for patients subjected to total pharyngolaryngectomy is a technique now universally accepted; however the literature on the subject is lacking. Our study considers 10 patients subjected to total pharyngolaryngectomy and restoration with pectoralis major myocutaneous flaps who were fitted with vocal function prostheses and a control group of 50 subjects treated with a total laryngectomy without pectoralis major myocutaneous flaps and who were fitted with vocal function prostheses. Specific qualitative and quantitative parameters were compared. The quantitative measurement of the levels of voice intensity and the evaluation of the harmonics-to-noise ratio were not statistically significant (p > 0.05) between the two study groups at either high- or low-volume speech. On the contrary, statistically significant differences were found (p < 0.05) for the basic frequency of both the low and the high volume voice. For the qualitative analysis seven parameters were established for evaluation by trained and untrained listeners: on the basis of these parameters the control group had statistically better voices.

  17. Maximal exercise testing variables and 10-year survival: fitness risk score derivation from the FIT Project.

    PubMed

    Ahmed, Haitham M; Al-Mallah, Mouaz H; McEvoy, John W; Nasir, Khurram; Blumenthal, Roger S; Jones, Steven R; Brawner, Clinton A; Keteyian, Steven J; Blaha, Michael J

    2015-03-01

    To determine which routinely collected exercise test variables most strongly correlate with survival and to derive a fitness risk score that can be used to predict 10-year survival. This was a retrospective cohort study of 58,020 adults aged 18 to 96 years who were free of established heart disease and were referred for an exercise stress test from January 1, 1991, through May 31, 2009. Demographic, clinical, exercise, and mortality data were collected on all patients as part of the Henry Ford ExercIse Testing (FIT) Project. Cox proportional hazards models were used to identify exercise test variables most predictive of survival. A "FIT Treadmill Score" was then derived from the β coefficients of the model with the highest survival discrimination. The median age of the 58,020 participants was 53 years (interquartile range, 45-62 years), and 28,201 (49%) were female. Over a median of 10 years (interquartile range, 8-14 years), 6456 patients (11%) died. After age and sex, peak metabolic equivalents of task and percentage of maximum predicted heart rate achieved were most highly predictive of survival (P<.001). Subsequent addition of baseline blood pressure and heart rate, change in vital signs, double product, and risk factor data did not further improve survival discrimination. The FIT Treadmill Score, calculated as [percentage of maximum predicted heart rate + 12(metabolic equivalents of task) - 4(age) + 43 if female], ranged from -200 to 200 across the cohort, was near normally distributed, and was found to be highly predictive of 10-year survival (Harrell C statistic, 0.811). The FIT Treadmill Score is easily attainable from any standard exercise test and translates basic treadmill performance measures into a fitness-related mortality risk score. The FIT Treadmill Score should be validated in external populations. Copyright © 2015 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  18. Quantitative analysis of crystalline pharmaceuticals in tablets by pattern-fitting procedure using X-ray diffraction pattern.

    PubMed

    Takehira, Rieko; Momose, Yasunori; Yamamura, Shigeo

    2010-10-15

    A pattern-fitting procedure using an X-ray diffraction pattern was applied to the quantitative analysis of binary system of crystalline pharmaceuticals in tablets. Orthorhombic crystals of isoniazid (INH) and mannitol (MAN) were used for the analysis. Tablets were prepared under various compression pressures using a direct compression method with various compositions of INH and MAN. Assuming that X-ray diffraction pattern of INH-MAN system consists of diffraction intensities from respective crystals, observed diffraction intensities were fitted to analytic expression based on X-ray diffraction theory and separated into two intensities from INH and MAN crystals by a nonlinear least-squares procedure. After separation, the contents of INH were determined by using the optimized normalization constants for INH and MAN. The correction parameter including all the factors that are beyond experimental control was required for quantitative analysis without calibration curve. The pattern-fitting procedure made it possible to determine crystalline phases in the range of 10-90% (w/w) of the INH contents. Further, certain characteristics of the crystals in the tablets, such as the preferred orientation, size of crystallite, and lattice disorder were determined simultaneously. This method can be adopted to analyze compounds whose crystal structures are known. It is a potentially powerful tool for the quantitative phase analysis and characterization of crystals in tablets and powders using X-ray diffraction patterns. Copyright 2010 Elsevier B.V. All rights reserved.

  19. The Quantitative-MFG Test: A Linear Mixed Effect Model to Detect Maternal-Offspring Gene Interactions.

    PubMed

    Clark, Michelle M; Blangero, John; Dyer, Thomas D; Sobel, Eric M; Sinsheimer, Janet S

    2016-01-01

    Maternal-offspring gene interactions, aka maternal-fetal genotype (MFG) incompatibilities, are neglected in complex diseases and quantitative trait studies. They are implicated in birth to adult onset diseases but there are limited ways to investigate their influence on quantitative traits. We present the quantitative-MFG (QMFG) test, a linear mixed model where maternal and offspring genotypes are fixed effects and residual correlations between family members are random effects. The QMFG handles families of any size, common or general scenarios of MFG incompatibility, and additional covariates. We develop likelihood ratio tests (LRTs) and rapid score tests and show they provide correct inference. In addition, the LRT's alternative model provides unbiased parameter estimates. We show that testing the association of SNPs by fitting a standard model, which only considers the offspring genotypes, has very low power or can lead to incorrect conclusions. We also show that offspring genetic effects are missed if the MFG modeling assumptions are too restrictive. With genome-wide association study data from the San Antonio Family Heart Study, we demonstrate that the QMFG score test is an effective and rapid screening tool. The QMFG test therefore has important potential to identify pathways of complex diseases for which the genetic etiology remains to be discovered. © 2015 John Wiley & Sons Ltd/University College London.

  20. Extended Theories of Gravitation. Observation Protocols and Experimental Tests

    NASA Astrophysics Data System (ADS)

    Fatibene, Lorenzo; Ferraris, Marco; Francaviglia, Mauro; Magnano, Guido

    2013-09-01

    Within the framework of extended theories of gravitation we shall discuss physical equivalences among different formalisms and classical tests. As suggested by the Ehlers-Pirani-Schild framework, the conformal invariance will be preserved and its effect on observational protocols discussed. Accordingly, we shall review standard tests showing how Palatini f(R)-theories naturally passes solar system tests. Observation protocols will be discussed in this wider framework.

  1. Indoor Exposure Product Testing Protocols Version 2

    EPA Science Inventory

    EPA’s Office of Pollution Prevention and Toxics (OPPT) has developed a set of ten indoor exposure testing protocols intended to provide information on the purpose of the testing, general description of the sampling and analytical procedures, and references for tests that will be ...

  2. Incremental value of Veterans Specific Activity Questionnaire and the YMCA-step test for the assessment of cardiorespiratory fitness in population-based studies.

    PubMed

    Teren, Andrej; Zachariae, Silke; Beutner, Frank; Ubrich, Romy; Sandri, Marcus; Engel, Christoph; Löffler, Markus; Gielen, Stephan

    2016-07-01

    Cardiorespiratory fitness is a well-established independent predictor of cardiovascular health. However, the relevance of alternative exercise and non-exercise tests for cardiorespiratory fitness assessment in large cohorts has not been studied in detail. We aimed to evaluate the YMCA-step test and the Veterans Specific Activity Questionnaire (VSAQ) for the estimation of cardiorespiratory fitness in the general population. One hundred and five subjects answered the VSAQ, performed the YMCA-step test and a maximal cardiopulmonary exercise test (CPX) and gave BORG ratings for both exercise tests (BORGSTEP, BORGCPX). Correlations of peak oxygen uptake on a treadmill (VO2_PEAK) with VSAQ, BORGSTEP, one-minute, post-exercise heartbeat count, and peak oxygen uptake during the step test (VO2_STEP) were determined. Moreover, the incremental values of the questionnaire and the step test in addition to other fitness-related parameters were evaluated using block-wise hierarchical regression analysis. Eighty-six subjects completed the step test according to the protocol. For completers, correlations of VO2_PEAK with the age- and gender-adjusted VSAQ, heartbeat count and VO2_STEP were 0.67, 0.63 and 0.49, respectively. However, using hierarchical regression analysis, age, gender and body mass index already explained 68.8% of the variance of VO2_PEAK, while the additional benefit of VSAQ was rather low (3.4%). The inclusion of BORGSTEP, heartbeat count and VO2_STEP increased R(2) by a further 2.2%, 3.3% and 5.6%, respectively, yielding a total R(2) of 83.3%. Neither VSAQ nor the YMCA-step test contributes sufficiently to the assessment of cardiorespiratory fitness in population-based studies. © The European Society of Cardiology 2015.

  3. Design and interpretation of anthropometric and fitness testing of basketball players.

    PubMed

    Drinkwater, Eric J; Pyne, David B; McKenna, Michael J

    2008-01-01

    The volume of literature on fitness testing in court sports such as basketball is considerably less than for field sports or individual sports such as running and cycling. Team sport performance is dependent upon a diverse range of qualities including size, fitness, sport-specific skills, team tactics, and psychological attributes. The game of basketball has evolved to have a high priority on body size and physical fitness by coaches and players. A player's size has a large influence on the position in the team, while the high-intensity, intermittent nature of the physical demands requires players to have a high level of fitness. Basketball coaches and sport scientists often use a battery of sport-specific physical tests to evaluate body size and composition, and aerobic fitness and power. This testing may be used to track changes within athletes over time to evaluate the effectiveness of training programmes or screen players for selection. Sports science research is establishing typical (or 'reference') values for both within-athlete changes and between-athlete differences. Newer statistical approaches such as magnitude-based inferences have emerged that are providing more meaningful interpretation of fitness testing results in the field for coaches and athletes. Careful selection and implementation of tests, and more pertinent interpretation of data, will enhance the value of fitness testing in high-level basketball programmes. This article presents reference values of fitness and body size in basketball players, and identifies practical methods of interpreting changes within players and differences between players beyond the null-hypothesis.

  4. Quantitative analysis of Ni2+/Ni3+ in Li[NixMnyCoz]O2 cathode materials: Non-linear least-squares fitting of XPS spectra

    NASA Astrophysics Data System (ADS)

    Fu, Zewei; Hu, Juntao; Hu, Wenlong; Yang, Shiyu; Luo, Yunfeng

    2018-05-01

    Quantitative analysis of Ni2+/Ni3+ using X-ray photoelectron spectroscopy (XPS) is important for evaluating the crystal structure and electrochemical performance of Lithium-nickel-cobalt-manganese oxide (Li[NixMnyCoz]O2, NMC). However, quantitative analysis based on Gaussian/Lorentzian (G/L) peak fitting suffers from the challenges of reproducibility and effectiveness. In this study, the Ni2+ and Ni3+ standard samples and a series of NMC samples with different Ni doping levels were synthesized. The Ni2+/Ni3+ ratios in NMC were quantitatively analyzed by non-linear least-squares fitting (NLLSF). Two Ni 2p overall spectra of synthesized Li [Ni0.33Mn0.33Co0.33]O2(NMC111) and bulk LiNiO2 were used as the Ni2+ and Ni3+ reference standards. Compared to G/L peak fitting, the fitting parameters required no adjustment, meaning that the spectral fitting process was free from operator dependence and the reproducibility was improved. Comparison of residual standard deviation (STD) showed that the fitting quality of NLLSF was superior to that of G/L peaks fitting. Overall, these findings confirmed the reproducibility and effectiveness of the NLLSF method in XPS quantitative analysis of Ni2+/Ni3+ ratio in Li[NixMnyCoz]O2 cathode materials.

  5. Protocol for concomitant temporomandibular joint custom-fitted total joint reconstruction and orthognathic surgery utilizing computer-assisted surgical simulation.

    PubMed

    Movahed, Reza; Teschke, Marcus; Wolford, Larry M

    2013-12-01

    Clinicians who address temporomandibular joint (TMJ) pathology and dentofacial deformities surgically can perform the surgery in 1 stage or 2 separate stages. The 2-stage approach requires the patient to undergo 2 separate operations and anesthesia, significantly prolonging the overall treatment. However, performing concomitant TMJ and orthognathic surgery (CTOS) in these cases requires careful treatment planning and surgical proficiency in the 2 surgical areas. This article presents a new treatment protocol for the application of computer-assisted surgical simulation in CTOS cases requiring reconstruction with patient-fitted total joint prostheses. The traditional and new CTOS protocols are described and compared. The new CTOS protocol helps decrease the preoperative workup time and increase the accuracy of model surgery. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Marginal fit and photoelastic stress analysis of CAD-CAM and overcast 3-unit implant-supported frameworks.

    PubMed

    Presotto, Anna Gabriella Camacho; Bhering, Cláudia Lopes Brilhante; Mesquita, Marcelo Ferraz; Barão, Valentim Adelino Ricardo

    2017-03-01

    Several studies have shown the superiority of computer-assisted design and computer-assisted manufacturing (CAD-CAM) technology compared with conventional casting. However, an advanced technology exists for casting procedures (the overcasting technique), which may serve as an acceptable and affordable alternative to CAD-CAM technology for fabricating 3-unit implant-supported fixed dental prostheses (FDPs). The purpose of this in vitro study was to evaluate, using quantitative photoelastic analysis, the effect of the prosthetic framework fabrication method (CAD-CAM and overcasting) on the marginal fit and stress transmitted to implants. The correlation between marginal fit and stress was also investigated. Three-unit implant-supported FDP frameworks were made using the CAD-CAM (n=10) and overcasting (n=10) methods. The frameworks were waxed to simulate a mandibular first premolar (PM region) to first molar (M region) FDP using overcast mini-abutment cylinders. The wax patterns were overcast (overcast experimental group) or scanned to obtain the frameworks (CAD-CAM control group). All frameworks were fabricated from cobalt-chromium (CoCr) alloy. The marginal fit was analyzed according to the single-screw test protocol, obtaining an average value for each region (M and PM) and each framework. The frameworks were tightened for the photoelastic model with standardized 10-Ncm torque. Stress was measured by quantitative photoelastic analysis. The results were submitted to the Student t test, 2-way ANOVA, and Pearson correlation test (α=.05). The framework fabrication method (FM) and evaluation site (ES; M and PM regions) did not affect the marginal fit values (P=.559 for FM and P=.065 for ES) and stress (P=.685 for FM and P=.468 for ES) in the implant-supported system. Positive correlations between marginal fit and stress were observed (CAD-CAM: r=0.922; P<.001; overcast: r=0.908; P<.001). CAD-CAM and overcasting methods present similar marginal fit and stress values

  7. Cylinder surface test with Chebyshev polynomial fitting method

    NASA Astrophysics Data System (ADS)

    Yu, Kui-bang; Guo, Pei-ji; Chen, Xi

    2017-10-01

    Zernike polynomials fitting method is often applied in the test of optical components and systems, used to represent the wavefront and surface error in circular domain. Zernike polynomials are not orthogonal in rectangular region which results in its unsuitable for the test of optical element with rectangular aperture such as cylinder surface. Applying the Chebyshev polynomials which are orthogonal among the rectangular area as an substitution to the fitting method, can solve the problem. Corresponding to a cylinder surface with diameter of 50 mm and F number of 1/7, a measuring system has been designed in Zemax based on Fizeau Interferometry. The expressions of the two-dimensional Chebyshev polynomials has been given and its relationship with the aberration has been presented. Furthermore, Chebyshev polynomials are used as base items to analyze the rectangular aperture test data. The coefficient of different items are obtained from the test data through the method of least squares. Comparing the Chebyshev spectrum in different misalignment, it show that each misalignment is independence and has a certain relationship with the certain Chebyshev terms. The simulation results show that, through the Legendre polynomials fitting method, it will be a great improvement in the efficient of the detection and adjustment of the cylinder surface test.

  8. Permutation tests for goodness-of-fit testing of mathematical models to experimental data.

    PubMed

    Fişek, M Hamit; Barlas, Zeynep

    2013-03-01

    This paper presents statistical procedures for improving the goodness-of-fit testing of theoretical models to data obtained from laboratory experiments. We use an experimental study in the expectation states research tradition which has been carried out in the "standardized experimental situation" associated with the program to illustrate the application of our procedures. We briefly review the expectation states research program and the fundamentals of resampling statistics as we develop our procedures in the resampling context. The first procedure we develop is a modification of the chi-square test which has been the primary statistical tool for assessing goodness of fit in the EST research program, but has problems associated with its use. We discuss these problems and suggest a procedure to overcome them. The second procedure we present, the "Average Absolute Deviation" test, is a new test and is proposed as an alternative to the chi square test, as being simpler and more informative. The third and fourth procedures are permutation versions of Jonckheere's test for ordered alternatives, and Kendall's tau(b), a rank order correlation coefficient. The fifth procedure is a new rank order goodness-of-fit test, which we call the "Deviation from Ideal Ranking" index, which we believe may be more useful than other rank order tests for assessing goodness-of-fit of models to experimental data. The application of these procedures to the sample data is illustrated in detail. We then present another laboratory study from an experimental paradigm different from the expectation states paradigm - the "network exchange" paradigm, and describe how our procedures may be applied to this data set. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Draft Plan to Develop Non-Intrusive Load Monitoring Test Protocols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mayhorn, Ebony T.; Sullivan, Greg P.; Petersen, Joseph M.

    2015-09-29

    This document presents a Draft Plan proposed to develop a common test protocol that can be used to evaluate the performance requirements of Non-Intrusive Load Monitoring. Development on the test protocol will be focused on providing a consistent method that can be used to quantify and compare the performance characteristics of NILM products. Elements of the protocols include specifications for appliances to be used, metrics, instrumentation, and a procedure to simulate appliance behavior during tests. In addition, three priority use cases for NILM will be identified and their performance requirements will specified.

  10. Combined approaches to flexible fitting and assessment in virus capsids undergoing conformational change☆

    PubMed Central

    Pandurangan, Arun Prasad; Shakeel, Shabih; Butcher, Sarah Jane; Topf, Maya

    2014-01-01

    Fitting of atomic components into electron cryo-microscopy (cryoEM) density maps is routinely used to understand the structure and function of macromolecular machines. Many fitting methods have been developed, but a standard protocol for successful fitting and assessment of fitted models has yet to be agreed upon among the experts in the field. Here, we created and tested a protocol that highlights important issues related to homology modelling, density map segmentation, rigid and flexible fitting, as well as the assessment of fits. As part of it, we use two different flexible fitting methods (Flex-EM and iMODfit) and demonstrate how combining the analysis of multiple fits and model assessment could result in an improved model. The protocol is applied to the case of the mature and empty capsids of Coxsackievirus A7 (CAV7) by flexibly fitting homology models into the corresponding cryoEM density maps at 8.2 and 6.1 Å resolution. As a result, and due to the improved homology models (derived from recently solved crystal structures of a close homolog – EV71 capsid – in mature and empty forms), the final models present an improvement over previously published models. In close agreement with the capsid expansion observed in the EV71 structures, the new CAV7 models reveal that the expansion is accompanied by ∼5° counterclockwise rotation of the asymmetric unit, predominantly contributed by the capsid protein VP1. The protocol could be applied not only to viral capsids but also to many other complexes characterised by a combination of atomic structure modelling and cryoEM density fitting. PMID:24333899

  11. Advanced orbiting systems test-bedding and protocol verification

    NASA Technical Reports Server (NTRS)

    Noles, James; De Gree, Melvin

    1989-01-01

    The Consultative Committee for Space Data Systems (CCSDS) has begun the development of a set of protocol recommendations for Advanced Orbiting Systems (SOS). The AOS validation program and formal definition of AOS protocols are reviewed, and the configuration control of the AOS formal specifications is summarized. Independent implementations of the AOS protocols by NASA and ESA are discussed, and cross-support/interoperability tests which will allow the space agencies of various countries to share AOS communication facilities are addressed.

  12. Task–Technology Fit of Video Telehealth for Nurses in an Outpatient Clinic Setting

    PubMed Central

    Finkelstein, Stanley M.

    2014-01-01

    Abstract Background: Incorporating telehealth into outpatient care delivery supports management of consumer health between clinic visits. Task–technology fit is a framework for understanding how technology helps and/or hinders a person during work processes. Evaluating the task–technology fit of video telehealth for personnel working in a pediatric outpatient clinic and providing care between clinic visits ensures the information provided matches the information needed to support work processes. Materials and Methods: The workflow of advanced practice registered nurse (APRN) care coordination provided via telephone and video telehealth was described and measured using a mixed-methods workflow analysis protocol that incorporated cognitive ethnography and time–motion study. Qualitative and quantitative results were merged and analyzed within the task–technology fit framework to determine the workflow fit of video telehealth for APRN care coordination. Results: Incorporating video telehealth into APRN care coordination workflow provided visual information unavailable during telephone interactions. Despite additional tasks and interactions needed to obtain the visual information, APRN workflow efficiency, as measured by time, was not significantly changed. Analyzed within the task–technology fit framework, the increased visual information afforded by video telehealth supported the assessment and diagnostic information needs of the APRN. Conclusions: Telehealth must provide the right information to the right clinician at the right time. Evaluating task–technology fit using a mixed-methods protocol ensured rigorous analysis of fit within work processes and identified workflows that benefit most from the technology. PMID:24841219

  13. Investigating the correlation of the U.S. Air Force Physical Fitness Test to combat-based fitness: a women-only study.

    PubMed

    Mitchell, Tarah; White, Edward D; Ritschel, Daniel

    2014-06-01

    The primary objective in this research involves determining the Air Force Physical Fitness Test's (AFPFT) predictability of combat fitness and whether measures within the AFPFT require modification to increase this predictability further. We recruited 60 female volunteers and compared their performance on the AFPFT to the Marine Combat Fitness Test, the proxy for combat fitness. We discovered little association between the two (R(2) of 0.35), however, this association significantly increased (adjusted R(2) of 0.56) when utilizing the raw scores of the AFPFT instead of using the gender/age scoring tables. Improving on these associations, we develop and propose a simple ordinary least squares regression model that minimally impacts the AFPFT testing routine. This two-event model for predicting combat fitness incorporates the 1.5-mile run along with the number of repetitions of a 30-lb dumbbell from chest height to overhead with arms extended during a 2-minute time span. These two events predicted combat fitness as assessed by the Marine Combat Fitness Test with an adjusted R(2) of 0.82. By adopting this model, we greatly improve the Air Force's ability to assess combat fitness for women. Reprint & Copyright © 2014 Association of Military Surgeons of the U.S.

  14. Exact goodness-of-fit tests for Markov chains.

    PubMed

    Besag, J; Mondal, D

    2013-06-01

    Goodness-of-fit tests are useful in assessing whether a statistical model is consistent with available data. However, the usual χ² asymptotics often fail, either because of the paucity of the data or because a nonstandard test statistic is of interest. In this article, we describe exact goodness-of-fit tests for first- and higher order Markov chains, with particular attention given to time-reversible ones. The tests are obtained by conditioning on the sufficient statistics for the transition probabilities and are implemented by simple Monte Carlo sampling or by Markov chain Monte Carlo. They apply both to single and to multiple sequences and allow a free choice of test statistic. Three examples are given. The first concerns multiple sequences of dry and wet January days for the years 1948-1983 at Snoqualmie Falls, Washington State, and suggests that standard analysis may be misleading. The second one is for a four-state DNA sequence and lends support to the original conclusion that a second-order Markov chain provides an adequate fit to the data. The last one is six-state atomistic data arising in molecular conformational dynamics simulation of solvated alanine dipeptide and points to strong evidence against a first-order reversible Markov chain at 6 picosecond time steps. © 2013, The International Biometric Society.

  15. Development of an efficient real-time quantitative PCR protocol for detection of Xanthomonas arboricola pv. pruni in Prunus species.

    PubMed

    Palacio-Bielsa, Ana; Cubero, Jaime; Cambra, Miguel A; Collados, Raquel; Berruete, Isabel M; López, María M

    2011-01-01

    Xanthomonas arboricola pv. pruni, the causal agent of bacterial spot disease of stone fruit, is considered a quarantine organism by the European Union and the European and Mediterranean Plant Protection Organization (EPPO). The bacterium can undergo an epiphytic phase and/or be latent and can be transmitted by plant material, but currently, only visual inspections are used to certify plants as being X. arboricola pv. pruni free. A novel and highly sensitive real-time TaqMan PCR detection protocol was designed based on a sequence of a gene for a putative protein related to an ABC transporter ATP-binding system in X. arboricola pv. pruni. Pathogen detection can be completed within a few hours with a sensitivity of 10(2) CFU ml(-1), thus surpassing the sensitivity of the existing conventional PCR. Specificity was assessed for X. arboricola pv. pruni strains from different origins as well as for closely related Xanthomonas species, non-Xanthomonas species, saprophytic bacteria, and healthy Prunus samples. The efficiency of the developed protocol was evaluated with field samples of 14 Prunus species and rootstocks. For symptomatic leaf samples, the protocol was very efficient even when washed tissues of the leaves were directly amplified without any previous DNA extraction. For samples of 117 asymptomatic leaves and 285 buds, the protocol was more efficient after a simple DNA extraction, and X. arboricola pv. pruni was detected in 9.4% and 9.1% of the 402 samples analyzed, respectively, demonstrating its frequent epiphytic or endophytic phase. This newly developed real-time PCR protocol can be used as a quantitative assay, offers a reliable and sensitive test for X. arboricola pv. pruni, and is suitable as a screening test for symptomatic as well as asymptomatic plant material.

  16. 16 CFR § 1212.4 - Test protocol.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...) The children for the test panel shall live within the United States. (4) The age and sex distribution... child in the 100-child test panel: (1) Sex (male or female). (2) Date of birth (month, day, year). (3... STANDARD FOR MULTI-PURPOSE LIGHTERS Requirements for Child-Resistance § 1212.4 Test protocol. (a) Child...

  17. The Current Often Implemented Fitness Tests in Physical Education Programs: Problems and Future Directions

    ERIC Educational Resources Information Center

    Keating, Xiaofen Deng

    2003-01-01

    This paper aims to examine current nationwide youth fitness test programs, address problems embedded in the programs, and possible solutions. The current Fitnessgram, President's Challenge, and YMCA youth fitness test programs were selected to represent nationwide youth fitness test programs. Sponsors of the nationwide youth fitness test programs…

  18. WittyFit-Live Your Work Differently: Study Protocol for a Workplace-Delivered Health Promotion.

    PubMed

    Dutheil, Frédéric; Duclos, Martine; Naughton, Geraldine; Dewavrin, Samuel; Cornet, Thomas; Huguet, Pascal; Chatard, Jean-Claude; Pereira, Bruno

    2017-04-13

    . WittyFit will evolve with the waves of connected objects further increasing its data accuracy. Ethical approval was obtained from the ethics committee of the University Hospital of Clermont-Ferrand, France. WittyFit recruitment and enrollment started in January 2016. First publications are expected to be available at the beginning of 2017. The name WittyFit came from Witty and Fitness. The concept of WittyFit reflects the concept of health from the World Health Organization: being spiritually and physically healthy. WittyFit is a health-monitoring, health-promoting tool that may improve the health of workers and health of companies. WittyFit will evolve with the waves of connected objects further increasing its data accuracy with objective measures. WittyFit may constitute a powerful epidemiological database. Finally, the WittyFit concept may extend healthy living into the general population. Clinicaltrials.gov: NCT02596737; https://www.clinicaltrials.gov/ct2/show/NCT02596737 (Archived by WebCite at http://www.webcitation.org/6pM5toQ7Y). ©Frédéric Dutheil, Martine Duclos, Geraldine Naughton, Samuel Dewavrin, Thomas Cornet, Pascal Huguet, Jean-Claude Chatard, Bruno Pereira. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 13.04.2017.

  19. 16 CFR § 1210.4 - Test protocol.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... live within the United States. (4) The age and sex distribution of each 100-child panel shall be: (i... recorded for each child in the 100-child test panel: (1) Sex (male or female). (2) Date of birth (month... STANDARD FOR CIGARETTE LIGHTERS Requirements for Child Resistance § 1210.4 Test protocol. (a) Child test...

  20. Sexing chick mRNA: A protocol based on quantitative real-time polymerase chain reaction.

    PubMed

    Wan, Z; Lu, Y; Rui, L; Yu, X; Li, Z

    2017-03-01

    The accurate identification of sex in birds is important for research on avian sex determination and differentiation. Polymerase chain reaction (PCR)-based methods have been widely applied for the molecular sexing of birds. However, these methods have used genomic DNA. Here, we present the first sexing protocol for chick mRNA based on real-time quantitative PCR. We demonstrate that this method can accurately determine sex using mRNA from chick gonads and other tissues, such as heart, liver, spleen, lung, and muscle. The strategy of this protocol also may be suitable for other species in which sex is determined by the inheritance of sex chromosomes (ZZ male and ZW female). © 2016 Poultry Science Association Inc.

  1. A Narrative Synthesis of Nintendo Wii Fit Gaming Protocol in Addressing Balance Among Healthy Older Adults: What System Works?

    PubMed

    Manlapaz, Donald G; Sole, Gisela; Jayakaran, Prasath; Chapple, Cathy M

    2017-04-01

    Balance is crucial in performing functional tasks particularly among older adults. Exergaming is gaining attention as a novel approach to enhance balance in a number of clinical populations. The aim of this review was to synthesize and present published evidence for Nintendo Wii Fit™ gaming system protocols. These include game preference, intervention setting, and exercise dosage for improving balance in healthy older adults. Commonly used outcome measures were also identified. A literature search was developed using the PICOS strategy using keywords such as "older adult," "Nintendo Wii Fit," "exergaming," and "balance" in the databases: MEDLINE, PubMed, EMBASE, CINAHL, Scopus, Science Direct, and Web of Science. Sixteen articles were included with participants (n = 491) mostly female (69%), and mean age ranged between 71 and 85 years old. Participants were recruited mainly from the community. The most commonly used Wii Fit games were Table tilt, Soccer Heading, Ski Slalom, and Ski jump, performed three times per week, with a duration of 30 minutes per session for 6 weeks. Berg Balance Scale, Timed Up and Go Test, and Centre of Pressure were the most commonly used outcome measures. Wii Fit exergames can be a potential alternative to improve balance if safety and technical procedures are provided. With conflicting and mechanism-based evidence on dosage presented, exergaming parameters require further research before firm recommendations can be made. Clinically, effective dosage is an important component in any type of interventions, and exergaming should not be an exception.

  2. Protocol vulnerability detection based on network traffic analysis and binary reverse engineering.

    PubMed

    Wen, Shameng; Meng, Qingkun; Feng, Chao; Tang, Chaojing

    2017-01-01

    Network protocol vulnerability detection plays an important role in many domains, including protocol security analysis, application security, and network intrusion detection. In this study, by analyzing the general fuzzing method of network protocols, we propose a novel approach that combines network traffic analysis with the binary reverse engineering method. For network traffic analysis, the block-based protocol description language is introduced to construct test scripts, while the binary reverse engineering method employs the genetic algorithm with a fitness function designed to focus on code coverage. This combination leads to a substantial improvement in fuzz testing for network protocols. We build a prototype system and use it to test several real-world network protocol implementations. The experimental results show that the proposed approach detects vulnerabilities more efficiently and effectively than general fuzzing methods such as SPIKE.

  3. Developing Effective Physical Fitness Testing Standards for Pre Service Physical Educators

    ERIC Educational Resources Information Center

    Hill, Kory; Thornburg, Roland

    2016-01-01

    Physical educators are often held to a higher standard of physical fitness. The ability to effectively convey the importance of physical fitness may depend upon the ability to appear physically fit. The ability to perform at a minimal level of proficiency on fitness tests was deemed important by the faculty of one physical education teacher…

  4. Test Protocols for Advanced Inverter Interoperability Functions - Appendices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Jay Dean; Gonzalez, Sigifredo; Ralph, Mark E.

    2013-11-01

    Distributed energy resources (DER) such as photovoltaic (PV) systems, when deployed in a large scale, are capable of influencing significantly the operation of power systems. Looking to the future, stakeholders are working on standards to make it possible to manage the potentially complex interactions between DER and the power system. In 2009, the Electric Power Research Institute (EPRI), Sandia National Laboratories (SNL) with the U.S. Department of Energy (DOE), and the Solar Electric Power Association (SEPA) initiated a large industry collaborative to identify and standardize definitions for a set of DER grid support functions. While the initial effort concentrated onmore » grid-tied PV inverters and energy storage systems, the concepts have applicability to all DER. A partial product of this on-going effort is a reference definitions document (IEC TR 61850-90-7, Object models for power converters in distributed energy resources (DER) systems) that has become a basis for expansion of related International Electrotechnical Commission (IEC) standards, and is supported by US National Institute of Standards and Technology (NIST) Smart Grid Interoperability Panel (SGIP). Some industry-led organizations advancing communications protocols have also embraced this work. As standards continue to evolve, it is necessary to develop test protocols to independently verify that the inverters are properly executing the advanced functions. Interoperability is assured by establishing common definitions for the functions and a method to test compliance with operational requirements. This document describes test protocols developed by SNL to evaluate the electrical performance and operational capabilities of PV inverters and energy storage, as described in IEC TR 61850-90-7. While many of these functions are not now required by existing grid codes or may not be widely available commercially, the industry is rapidly moving in that direction. Interoperability issues are already

  5. A Passive Testing Approach for Protocols in Wireless Sensor Networks

    PubMed Central

    Che, Xiaoping; Maag, Stephane; Tan, Hwee-Xian; Tan, Hwee-Pink; Zhou, Zhangbing

    2015-01-01

    Smart systems are today increasingly developed with the number of wireless sensor devices drastically increasing. They are implemented within several contexts throughout our environment. Thus, sensed data transported in ubiquitous systems are important, and the way to carry them must be efficient and reliable. For that purpose, several routing protocols have been proposed for wireless sensor networks (WSN). However, one stage that is often neglected before their deployment is the conformance testing process, a crucial and challenging step. Compared to active testing techniques commonly used in wired networks, passive approaches are more suitable to the WSN environment. While some works propose to specify the protocol with state models or to analyze them with simulators and emulators, we here propose a logic-based approach for formally specifying some functional requirements of a novel WSN routing protocol. We provide an algorithm to evaluate these properties on collected protocol execution traces. Further, we demonstrate the efficiency and suitability of our approach by its application into common WSN functional properties, as well as specific ones designed from our own routing protocol. We provide relevant testing verdicts through a real indoor testbed and the implementation of our protocol. Furthermore, the flexibility, genericity and practicability of our approach have been proven by the experimental results. PMID:26610495

  6. A Passive Testing Approach for Protocols in Wireless Sensor Networks.

    PubMed

    Che, Xiaoping; Maag, Stephane; Tan, Hwee-Xian; Tan, Hwee-Pink; Zhou, Zhangbing

    2015-11-19

    Smart systems are today increasingly developed with the number of wireless sensor devices drastically increasing. They are implemented within several contexts throughout our environment. Thus, sensed data transported in ubiquitous systems are important, and the way to carry them must be efficient and reliable. For that purpose, several routing protocols have been proposed for wireless sensor networks (WSN). However, one stage that is often neglected before their deployment is the conformance testing process, a crucial and challenging step. Compared to active testing techniques commonly used in wired networks, passive approaches are more suitable to the WSN environment. While some works propose to specify the protocol with state models or to analyze them with simulators and emulators, we here propose a logic-based approach for formally specifying some functional requirements of a novel WSN routing protocol. We provide an algorithm to evaluate these properties on collected protocol execution traces. Further, we demonstrate the efficiency and suitability of our approach by its application into common WSN functional properties, as well as specific ones designed from our own routing protocol. We provide relevant testing verdicts through a real indoor testbed and the implementation of our protocol. Furthermore, the flexibility, genericity and practicability of our approach have been proven by the experimental results.

  7. Peak oxygen uptake in a sprint interval testing protocol vs. maximal oxygen uptake in an incremental testing protocol and their relationship with cross-country mountain biking performance.

    PubMed

    Hebisz, Rafał; Hebisz, Paulina; Zatoń, Marek; Michalik, Kamil

    2017-04-01

    In the literature, the exercise capacity of cyclists is typically assessed using incremental and endurance exercise tests. The aim of the present study was to confirm whether peak oxygen uptake (V̇O 2peak ) attained in a sprint interval testing protocol correlates with cycling performance, and whether it corresponds to maximal oxygen uptake (V̇O 2max ) determined by an incremental testing protocol. A sample of 28 trained mountain bike cyclists executed 3 performance tests: (i) incremental testing protocol (ITP) in which the participant cycled to volitional exhaustion, (ii) sprint interval testing protocol (SITP) composed of four 30 s maximal intensity cycling bouts interspersed with 90 s recovery periods, (iii) competition in a simulated mountain biking race. Oxygen uptake, pulmonary ventilation, work, and power output were measured during the ITP and SITP with postexercise blood lactate and hydrogen ion concentrations collected. Race times were recorded. No significant inter-individual differences were observed in regards to any of the ITP-associated variables. However, 9 individuals presented significantly increased oxygen uptake, pulmonary ventilation, and work output in the SITP compared with the remaining cyclists. In addition, in this group of 9 cyclists, oxygen uptake in SITP was significantly higher than in ITP. After the simulated race, this group of 9 cyclists achieved significantly better competition times (99.5 ± 5.2 min) than the other cyclists (110.5 ± 6.7 min). We conclude that mountain bike cyclists who demonstrate higher peak oxygen uptake in a sprint interval testing protocol than maximal oxygen uptake attained in an incremental testing protocol demonstrate superior competitive performance.

  8. Quantitative Comparison of 21 Protocols for Labeling Hippocampal Subfields and Parahippocampal Subregions in In Vivo MRI: Towards a Harmonized Segmentation Protocol

    PubMed Central

    Yushkevich, Paul A.; Amaral, Robert S. C.; Augustinack, Jean C.; Bender, Andrew R.; Bernstein, Jeffrey D.; Boccardi, Marina; Bocchetta, Martina; Burggren, Alison C.; Carr, Valerie A.; Chakravarty, M. Mallar; Chetelat, Gael; Daugherty, Ana M.; Davachi, Lila; Ding, Song-Lin; Ekstrom, Arne; Geerlings, Mirjam I.; Hassan, Abdul; Huang, Yushan; Iglesias, Eugenio; La Joie, Renaud; Kerchner, Geoffrey A.; LaRocque, Karen F.; Libby, Laura A.; Malykhin, Nikolai; Mueller, Susanne G.; Olsen, Rosanna K.; Palombo, Daniela J.; Parekh, Mansi B; Pluta, John B.; Preston, Alison R.; Pruessner, Jens C.; Ranganath, Charan; Raz, Naftali; Schlichting, Margaret L.; Schoemaker, Dorothee; Singh, Sachi; Stark, Craig E. L.; Suthana, Nanthia; Tompary, Alexa; Turowski, Marta M.; Van Leemput, Koen; Wagner, Anthony D.; Wang, Lei; Winterburn, Julie L.; Wisse, Laura E.M.; Yassa, Michael A.; Zeineh, Michael M.

    2015-01-01

    OBJECTIVE An increasing number of human in vivo magnetic resonance imaging (MRI) studies have focused on examining the structure and function of the subfields of the hippocampal formation (the dentate gyrus, CA fields 1–3, and the subiculum) and subregions of the parahippocampal gyrus (entorhinal, perirhinal, and parahippocampal cortices). The ability to interpret the results of such studies and to relate them to each other would be improved if a common standard existed for labeling hippocampal subfields and parahippocampal subregions. Currently, research groups label different subsets of structures and use different rules, landmarks, and cues to define their anatomical extents. This paper characterizes, both qualitatively and quantitatively, the variability in the existing manual segmentation protocols for labeling hippocampal and parahippocampal substructures in MRI, with the goal of guiding subsequent work on developing a harmonized substructure segmentation protocol. METHOD MRI scans of a single healthy adult human subject were acquired both at 3 Tesla and 7 Tesla. Representatives from 21 research groups applied their respective manual segmentation protocols to the MRI modalities of their choice. The resulting set of 21 segmentations was analyzed in a common anatomical space to quantify similarity and identify areas of agreement. RESULTS The differences between the 21 protocols include the region within which segmentation is performed, the set of anatomical labels used, and the extents of specific anatomical labels. The greatest overall disagreement among the protocols is at the CA1/subiculum boundary, and disagreement across all structures is greatest in the anterior portion of the hippocampal formation relative to the body and tail. CONCLUSIONS The combined examination of the 21 protocols in the same dataset suggests possible strategies towards developing a harmonized subfield segmentation protocol and facilitates comparison between published studies. PMID

  9. Quantum chi-squared and goodness of fit testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Temme, Kristan; Verstraete, Frank

    2015-01-15

    A quantum mechanical hypothesis test is presented for the hypothesis that a certain setup produces a given quantum state. Although the classical and the quantum problems are very much related to each other, the quantum problem is much richer due to the additional optimization over the measurement basis. A goodness of fit test for i.i.d quantum states is developed and a max-min characterization for the optimal measurement is introduced. We find the quantum measurement which leads both to the maximal Pitman and Bahadur efficiencies, and determine the associated divergence rates. We discuss the relationship of the quantum goodness of fitmore » test to the problem of estimating multiple parameters from a density matrix. These problems are found to be closely related and we show that the largest error of an optimal strategy, determined by the smallest eigenvalue of the Fisher information matrix, is given by the divergence rate of the goodness of fit test.« less

  10. 78 FR 39190 - Revisions to Fitness for Duty Programs' Drug Testing Requirements

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-01

    ...-0225] RIN 3150-AI67 Revisions to Fitness for Duty Programs' Drug Testing Requirements AGENCY: Nuclear... regarding drug testing requirements in NRC licensees' fitness for duty programs. The regulatory basis...

  11. VO2max Testing in Trail Runners: Is There a Specific Exercise Test Protocol?

    PubMed

    Scheer, Volker; Ramme, Katharina; Reinsberger, Claus; Heitkamp, Hans-Christian

    2018-06-01

    Trail running places specific physiological demands on the human body due to its uphill and downhill running sections. We developed and investigated a more sport-specific trail exercise test protocol (inclination and speed incremental protocol), and compared it to two standard exercise test protocols (horizontal step and ramp protocol) in thirteen highly trained trail runners (age 31±6 years, height 179±6.4 cm, weight 69.2±7.9 kg, BMI 21.6±2.1 kg/m 2 ). The maximum oxygen uptake (VO 2 max) measured during the trail test (62.5±5.9 ml·kg -1 ·min -1 , [95% CI: 59.0-66.1]) was significantly higher compared to both the step test (60.1±5.3 ml·kg -1 ·min -1 , [95% CI: 56.8-63.3], p=0.024) and the ramp test (59.7±5.5 ml·kg -1 ·min -1 , [95% CI: 56.4-63.0], p=0.028). Time to task failure was significantly shorter in the trail test (557±73 s, [95% CI: 512-601]) compared to both the step test (1378±152 s, [95% CI: 1286-1470], p<0.001) and the ramp test (605±95, [95% CI: 547-662], p<0.001). Other physiological measurements obtained were similar. The trail test was the preferred choice in our group of trail runners. This study supports the implementation of the trail test in practice, and recommends that its validity be evaluated further. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Self-reported physical activity and preaccession fitness testing in U.S. Army applicants.

    PubMed

    Gubata, Marlene E; Cowan, David N; Bedno, Sheryl A; Urban, Nadia; Niebuhr, David W

    2011-08-01

    The Assessment of Recruit Motivation and Strength (ARMS) study evaluated a physical fitness screening test for Army applicants before basic training. This report examines applicants' self-reported physical activity as a predictor of objective fitness measured by ARMS. In 2006, the ARMS study administered a fitness test and physical activity survey to Army applicants during their medical evaluation, using multiple logistic regression for comparison. Among both men and women, "qualified" and "exceeds-body-fat" subjects who met American College of Sports Medicine adult physical activity guidelines were more likely to pass the fitness test. Overall, subjects who met physical activity recommendations, watched less television, and played on sports teams had a higher odds of passing the ARMS test after adjustment for age, race, and smoking status. This study demonstrates that self-reported physical activity was associated with physical fitness and may be used to identify those at risk of failing a preaccession fitness test.

  13. Sport specific fitness testing of elite badminton players.

    PubMed Central

    Chin, M K; Wong, A S; So, R C; Siu, O T; Steininger, K; Lo, D T

    1995-01-01

    There is a scarcity of descriptive data on the performance capacity of elite badminton players, whose fitness requirements are quite specific. The purpose of this paper is to investigate the physiological response of elite badminton players in a sport-specific fitness test. Twelve Hong Kong national badminton team players performed a field test on a badminton court. Six light bulbs were connected to a programming device causing individual bulbs to light up in a given sequence. The players were instructed to react to the flashes by running towards them, and striking shuttles mounted in the vicinity of the bulbs. Exercise intensity was controlled by altering the interval between successive lightings. A low correlation (r = 0.65) was found between the results of the field test and the rank-order list of subjects, based on an objective on-field physiological assessment and subjective ranking. This may be explained by the requirements of other factors besides physical fitness which contribute to success in elite level badminton competition. These factors may include, for example, technical skill, mental power, and aesthetic judgements on the court. Maximum mean (s.d.) heart rate data (187(8) beats.min-1) and blood lactate values (10.4(2.9) mmol.l-1) in this study showed that players were under maximal load during the field test. From the testing data, it seems reasonable to speculate that the intensity of level 3 (20 light pulses.min-1; 3.0 s.pulse-1) and level 4 (22 light pulses.min-1; 2.7 s.pulse-1) simulates the requirement of actual games energy expenditure of the Hong Kong badminton players exercising at close to their anaerobic threshold. The results also show that an estimate of fitness can be derived from measurements involving exercise closely resembling that which is specific for the sports activity in question. Improved training advice and guidance may result from such studies. PMID:8800846

  14. Student Motivation Associated with Fitness Testing in the Physical Education Context

    ERIC Educational Resources Information Center

    Jaakkola, Timo Tapio; Sääkslahti, Arja; Yli-Piipari, Sami; Manninen, Mika; Watt, Anthony; Liukkonen, Jarmo

    2013-01-01

    The purpose of the study was to analyze students' motivation in relation to their participation in fitness testing classes. Participants were 134 Finnish Grade 5 and 8 students. Students completed the contextual motivation and perceived physical competence scales before the fitness testing class and the situational motivation questionnaire…

  15. Improving the Sandia Test Protocols with Advanced Inverter Functionality Testing of INV3, VV11, FW21, and L/HVRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Jay Dean

    2013-11-01

    Sandia National Laboratories has created a test protocol for IEC TR 61850-90-7 advanced distributed energy resource (DER) functions, titled "Test Protocols for Advanced Inverter Interoperability Functions," often referred to as the Sandia Test Protocols. This document is currently in draft form, but has been shared with stakeholders around the world with the ultimate goal of collaborating to create a consensus set of test protocols which can be then incorporated into an International Electrotechnical Commission (IEC) and/or Underwriters Laboratories (UL) certification standard. The protocols are designed to ensure functional interoperability of DER (primarily photovoltaic (PV) inverters and energy storage systems) asmore » specified by the IEC technical report through communication and electrical tests. In this report, Sandia exercises the electrical characterization portion of the test protocols for four functions: constant power factor (INV3), volt-var (VV11), frequency-watt (FW21), and Low and High Voltage Ride Through (L/HVRT). The goal of the tests reported here was not to characterize the performance of the equipment under test (EUT), but rather to (a) exercise the draft Sandia Test Protocols in order to identify any revisions needed in test procedures, conditions, or equipment and (b) gain experience with state-of-the-art DER equipment to determine if the tests put unrealistic or overly aggressive requirements on EUT operation. In performing the work according to the current versions of the protocols, Sandia was able to identify weaknesses in the current versions and suggest improvements to the test protocols.« less

  16. Low aerobic fitness and obesity are associated with lower standardized test scores in children.

    PubMed

    Roberts, Christian K; Freed, Benjamin; McCarthy, William J

    2010-05-01

    To investigate whether aerobic fitness and obesity in school children are associated with standardized test performance. Ethnically diverse (n = 1989) 5th, 7th, and 9th graders attending California schools comprised the sample. Aerobic fitness was determined by a 1-mile run/walk test; body mass index (BMI) was obtained from state-mandated measurements. California standardized test scores were obtained from the school district. Students whose mile run/walk times exceeded California Fitnessgram standards or whose BMI exceeded Centers for Disease Control sex- and age-specific body weight standards scored lower on California standardized math, reading, and language tests than students with desirable BMI status or fitness level, even after controlling for parent education among other covariates. Ethnic differences in standardized test scores were consistent with ethnic differences in obesity status and aerobic fitness. BMI-for-age was no longer a significant multivariate predictor when covariates included fitness level. Low aerobic fitness is common among youth and varies among ethnic groups, and aerobic fitness level predicts performance on standardized tests across ethnic groups. More research is needed to uncover the physiological mechanisms by which aerobic fitness may contribute to performance on standardized academic tests.

  17. Statewide Physical Fitness Testing: A BIG Waist or a BIG Waste?

    ERIC Educational Resources Information Center

    Morrow, James R., Jr.; Ede, Alison

    2009-01-01

    Statewide physical fitness testing is gaining popularity in the United States because of increased childhood obesity levels, the relations between physical fitness and academic performance, and the hypothesized relations between adult characteristics and childhood physical activity, physical fitness, and health behaviors. Large-scale physical…

  18. Statewide Physical Fitness Testing: Perspectives from the Gym

    ERIC Educational Resources Information Center

    Martin, Scott B.; Ede, Alison; Morrow, James R., Jr.; Jackson, Allen W.

    2010-01-01

    This paper provides observations of physical fitness testing in Texas schools and physical education teachers' insights about large-scale testing using the FITNESSGRAM[R] assessment (Cooper Institute, 2007) as mandated by Texas Senate Bill 530. In the first study, undergraduate and graduate students who were trained to observe and assess student…

  19. A comparison of manual and quantitative elbow strength testing.

    PubMed

    Shahgholi, Leili; Bengtson, Keith A; Bishop, Allen T; Shin, Alexander Y; Spinner, Robert J; Basford, Jeffrey R; Kaufman, Kenton R

    2012-10-01

    The aim of this study was to compare the clinical ratings of elbow strength obtained by skilled clinicians with objective strength measurement obtained through quantitative testing. A retrospective comparison of subject clinical records with quantitative strength testing results in a motion analysis laboratory was conducted. A total of 110 individuals between the ages of 8 and 65 yrs with traumatic brachial plexus injuries were identified. Patients underwent manual muscle strength testing as assessed on the 5-point British Medical Research Council Scale (5/5, normal; 0/5, absent) and quantitative elbow flexion and extension strength measurements. A total of 92 subjects had elbow flexion testing. Half of the subjects clinically assessed as having normal (5/5) elbow flexion strength on manual muscle testing exhibited less than 42% of their age-expected strength on quantitative testing. Eighty-four subjects had elbow extension strength testing. Similarly, half of those displaying normal elbow extension strength on manual muscle testing were found to have less than 62% of their age-expected values on quantitative testing. Significant differences between manual muscle testing and quantitative findings were not detected for the lesser (0-4) strength grades. Manual muscle testing, even when performed by experienced clinicians, may be more misleading than expected for subjects graded as having normal (5/5) strength. Manual muscle testing estimates for the lesser strength grades (1-4/5) seem reasonably accurate.

  20. Epigenetics and sex-specific fitness: an experimental test using male-limited evolution in Drosophila melanogaster.

    PubMed

    Abbott, Jessica K; Innocenti, Paolo; Chippindale, Adam K; Morrow, Edward H

    2013-01-01

    When males and females have different fitness optima for the same trait but share loci, intralocus sexual conflict is likely to occur. Epigenetic mechanisms such as genomic imprinting (in which expression is altered according to parent-of-origin) and sex-specific maternal effects have been suggested as ways by which this conflict can be resolved. However these ideas have not yet been empirically tested. We designed an experimental evolution protocol in Drosophila melanogaster that enabled us to look for epigenetic effects on the X-chromosome-a hotspot for sexually antagonistic loci. We used special compound-X females to enforce father-to-son transmission of the X-chromosome for many generations, and compared fitness and gene expression levels between Control males, males with a Control X-chromosome that had undergone one generation of father-son transmission, and males with an X-chromosome that had undergone many generations of father-son transmission. Fitness differences were dramatic, with experimentally-evolved males approximately 20% greater than controls, and with males inheriting a non-evolved X from their father about 20% lower than controls. These data are consistent with both strong intralocus sexual conflict and misimprinting of the X-chromosome under paternal inheritance. However, expression differences suggested that reduced fitness under paternal X inheritance was largely due to deleterious maternal effects. Our data confirm the sexually-antagonistic nature of Drosophila's X-chromosome and suggest that the response to male-limited X-chromosome evolution entails compensatory evolution for maternal effects, and perhaps modification of other epigenetic effects via coevolution of the sex chromosomes.

  1. Overcoming pain thresholds with multilevel models-an example using quantitative sensory testing (QST) data.

    PubMed

    Hirschfeld, Gerrit; Blankenburg, Markus R; Süß, Moritz; Zernikow, Boris

    2015-01-01

    The assessment of somatosensory function is a cornerstone of research and clinical practice in neurology. Recent initiatives have developed novel protocols for quantitative sensory testing (QST). Application of these methods led to intriguing findings, such as the presence lower pain-thresholds in healthy children compared to healthy adolescents. In this article, we (re-) introduce the basic concepts of signal detection theory (SDT) as a method to investigate such differences in somatosensory function in detail. SDT describes participants' responses according to two parameters, sensitivity and response-bias. Sensitivity refers to individuals' ability to discriminate between painful and non-painful stimulations. Response-bias refers to individuals' criterion for giving a "painful" response. We describe how multilevel models can be used to estimate these parameters and to overcome central critiques of these methods. To provide an example we apply these methods to data from the mechanical pain sensitivity test of the QST protocol. The results show that adolescents are more sensitive to mechanical pain and contradict the idea that younger children simply use more lenient criteria to report pain. Overall, we hope that the wider use of multilevel modeling to describe somatosensory functioning may advance neurology research and practice.

  2. A Comparison of the US Air Force Fitness Test and Sister Services’ Combat-Oriented Fitness Tests

    DTIC Science & Technology

    2009-03-01

    could lead to injuries such as twisted ankles, sprains, bruises, lower back pain, abdominal cramps and pain, muscle fatigue , strains, exhaustion, nausea...twisted ankles, sprains, bruises, lower back pain, abdominal cramps and pain, muscle fatigue , strains, exhaustion, nausea, headaches, or other...combat skills, anaerobic exercises, and burst speed exercises. They have, or are in the process of, creating their own versions of combat fitness tests

  3. Quantitative sensory testing of neuropathic pain patients: potential mechanistic and therapeutic implications.

    PubMed

    Pfau, Doreen B; Geber, Christian; Birklein, Frank; Treede, Rolf-Detlef

    2012-06-01

    Quantitative sensory testing (QST) is a widely accepted tool to investigate somatosensory changes in pain patients. Many different protocols have been developed in clinical pain research within recent years. In this review, we provide an overview of QST and tested neuroanatomical pathways, including peripheral and central structures. Based on research studies using animal and human surrogate models of neuropathic pain, possible underlying mechanisms of chronic pain are discussed. Clinically, QST may be useful for 1) the identification of subgroups of patients with different underlying pain mechanisms; 2) prediction of therapeutic outcomes; and 3) quantification of therapeutic interventions in pain therapy. Combined with sensory mapping, QST may provide useful information on the site of neural damage and on mechanisms of positive and negative somatosensory abnormalities. The use of QST in individual patients for diagnostic purposes leading to individualized therapy is an interesting concept, but needs further validation.

  4. Test-retest agreement and reliability of quantitative sensory testing 1 year after breast cancer surgery.

    PubMed

    Andersen, Kenneth Geving; Kehlet, Henrik; Aasvang, Eske Kvanner

    2015-05-01

    Quantitative sensory testing (QST) is used to assess sensory dysfunction and nerve damage by examining psychophysical responses to controlled, graded stimuli such as mechanical and thermal detection and pain thresholds. In the breast cancer population, 4 studies have used QST to examine persistent pain after breast cancer treatment, suggesting neuropathic pain being a prominent pain mechanism. However, the agreement and reliability of QST has not been described in the postsurgical breast cancer population, hindering exact interpretation of QST studies in this population. The aim of the present study was to assess test-retest properties of QST after breast cancer surgery. A total of 32 patients recruited from a larger ongoing prospective trial were examined with QST 12 months after breast cancer surgery and reexamined a week later. A standardized QST protocol was used, including sensory mapping for mechanical, warmth and cold areas of sensory dysfunction, mechanical thresholds using monofilaments and pin-prick, thermal thresholds including warmth and cold detection thresholds and heat pain threshold, with bilateral examination. Agreement and reliability were assessed by Bland-Altman plots, descriptive statistics, coefficients of variance, and intraclass correlation. Bland-Altman plots showed high variation on the surgical side. Intraclass coefficients ranged from 0.356 to 0.847 (moderate to substantial reliability). Between-patient variation was generally higher (0.9 to 14.5 SD) than within-patient variation (0.23 to 3.55 SD). There were no significant differences between pain and pain-free patients. The individual test-retest variability was higher on the operated side compared with the nonoperated side. The QST protocol reliability allows for group-to-group comparison of sensory function, but less so for individual follow-up after breast cancer surgery.

  5. Hearing protector fit testing with off-shore oil-rig inspectors in Louisiana and Texas.

    PubMed

    Murphy, William J; Themann, Christa L; Murata, Taichi K

    2016-11-01

    This field study aimed to assess the noise reduction of hearing protection for individual workers, demonstrate the effectiveness of training on the level of protection achieved, and measure the time required to implement hearing protector fit testing in the workplace. The National Institute for Occupational Safety and Health (NIOSH) conducted field studies in Louisiana and Texas to test the performance of HPD Well-Fit. Fit tests were performed on 126 inspectors and engineers working in the offshore oil industry. Workers were fit tested with the goal of achieving a 25-dB PAR. Less than half of the workers were achieving sufficient protection from their hearing protectors prior to NIOSH intervention and training; following re-fitting and re-training, over 85% of the workers achieved sufficient protection. Typical test times were 6-12 minutes. Fit testing of the workers' earplugs identified those workers who were and were not achieving the desired level of protection. Recommendations for other hearing protection solutions were made for workers who could not achieve the target PAR. The study demonstrates the need for individual hearing protector fit testing and addresses some of the barriers to implementation.

  6. A review of polymer electrolyte membrane fuel cell durability test protocols

    NASA Astrophysics Data System (ADS)

    Yuan, Xiao-Zi; Li, Hui; Zhang, Shengsheng; Martin, Jonathan; Wang, Haijiang

    Durability is one of the major barriers to polymer electrolyte membrane fuel cells (PEMFCs) being accepted as a commercially viable product. It is therefore important to understand their degradation phenomena and analyze degradation mechanisms from the component level to the cell and stack level so that novel component materials can be developed and novel designs for cells/stacks can be achieved to mitigate insufficient fuel cell durability. It is generally impractical and costly to operate a fuel cell under its normal conditions for several thousand hours, so accelerated test methods are preferred to facilitate rapid learning about key durability issues. Based on the US Department of Energy (DOE) and US Fuel Cell Council (USFCC) accelerated test protocols, as well as degradation tests performed by researchers and published in the literature, we review degradation test protocols at both component and cell/stack levels (driving cycles), aiming to gather the available information on accelerated test methods and degradation test protocols for PEMFCs, and thereby provide practitioners with a useful toolbox to study durability issues. These protocols help prevent the prolonged test periods and high costs associated with real lifetime tests, assess the performance and durability of PEMFC components, and ensure that the generated data can be compared.

  7. Quantitative optical scanning tests of complex microcircuits

    NASA Technical Reports Server (NTRS)

    Erickson, J. J.

    1980-01-01

    An approach for the development of the optical scanner as a screening inspection instrument for microcircuits involves comparing the quantitative differences in photoresponse images and then correlating them with electrical parameter differences in test devices. The existing optical scanner was modified so that the photoresponse data could be recorded and subsequently digitized. A method was devised for applying digital image processing techniques to the digitized photoresponse data in order to quantitatively compare the data. Electrical tests were performed and photoresponse images were recorded before and following life test intervals on two groups of test devices. Correlations were made between differences or changes in the electrical parameters of the test devices.

  8. A descriptive study of the U.S. Marine Corps fitness tests (2000-2012).

    PubMed

    Bartlett, Jamie L; Phillips, Jennifer; Galarneau, Michael R

    2015-05-01

    This article describes the performance of active duty U.S. Marines on the Physical Fitness Test (PFT) and Combat Fitness Test (CFT) during calendar years 2000 through 2012. Our study sample included PFT composite scores (n = 543,185), PFT and CFT composite scores (n = 160,936), and PFT and CFT event scores (n = 135,926 and n = 201,953, respectively). In general, all Marines performed very well on each fitness test, with overall annual improvements. Interestingly, the majority of female Marines passed the minimum male standard on the CFT. Further studies will evaluate the relationship of fitness test performance and injury. Reprint & Copyright © 2015 Association of Military Surgeons of the U.S.

  9. Proof of concept of a 45-second cardiorespiratory fitness self-test for coronary artery disease patients based on accelerometry.

    PubMed

    Papini, Gabriele; Bonomi, Alberto G; Stut, Wim; Kraal, Jos J; Kemps, Hareld M C; Sartor, Francesco

    2017-01-01

    Cardiorespiratory fitness (CRF) provides important diagnostic and prognostic information. It is measured directly via laboratory maximal testing or indirectly via submaximal protocols making use of predictor parameters such as submaximal [Formula: see text], heart rate, workload, and perceived exertion. We have established an innovative methodology, which can provide CRF prediction based only on body motion during a periodic movement. Thirty healthy subjects (40% females, 31.3 ± 7.8 yrs, 25.1 ± 3.2 BMI) and eighteen male coronary artery disease (CAD) (56.6 ± 7.4 yrs, 28.7 ± 4.0 BMI) patients performed a [Formula: see text] test on a cycle ergometer as well as a 45 second squatting protocol at a fixed tempo (80 bpm). A tri-axial accelerometer was used to monitor movements during the squat exercise test. Three regression models were developed to predict CRF based on subject characteristics and a new accelerometer-derived feature describing motion decay. For each model, the Pearson correlation coefficient and the root mean squared error percentage were calculated using the leave-one-subject-out cross-validation method (rcv, RMSEcv). The model built with all healthy individuals' data showed an rcv = 0.68 and an RMSEcv = 16.7%. The CRF prediction improved when only healthy individuals with normal to lower fitness (CRF<40 ml/min/kg) were included, showing an rcv = 0.91 and RMSEcv = 8.7%. Finally, our accelerometry-based CRF prediction CAD patients, the majority of whom taking β-blockers, still showed high accuracy (rcv = 0.91; RMSEcv = 9.6%). In conclusion, motion decay and subject characteristics could be used to predict CRF in healthy people as well as in CAD patients taking β-blockers, accurately. This method could represent a valid alternative for patients taking β-blockers, but needs to be further validated in a larger population.

  10. Indices of abdominal adiposity and cardiorespiratory fitness test performance in middle-school students.

    PubMed

    Burns, Ryan; Hannon, James C; Brusseau, Timothy A; Shultz, Barry; Eisenman, Patricia

    2013-01-01

    Previous research suggests that use of BMI as a screening tool to assess health in youth has limitations. Valid alternative measures to assess body composition are needed to accurately identify children who are aerobically fit, which is an indicator of health status. The purpose of this study was to examine the associations between select anthropometric measures and cardiorespiratory fitness test performance in middle-school students. Participants included 134 students (65 boys and 69 girls) recruited from the 6th, 7th, and 8th grades. Anthropometric measures consisted of BMI, waist circumference (WC), waist-to-height ratio (WHtR), and percent body fat estimated from two-site skinfolds (%BF-SKF), as well as the hand-held OMRON BIA device (%BF-BIA). Cardiorespiratory fitness tests included the one-mile run and PACER test. Data were collected on four separate testing days during the students' physical education classes. There were statistically significant moderate correlations between the %BF estimations, WHtR, and cardiorespiratory fitness test scores in both genders (P < .001). BMI at best only displayed weak correlations with the cardiorespiratory fitness test scores. The results suggest that alternative measures such as %BF-SKF, %BF-BIA, and WHtR may be more valid indicators of youth aerobic fitness lending to their preferred use over BMI.

  11. Entropy-based goodness-of-fit test: Application to the Pareto distribution

    NASA Astrophysics Data System (ADS)

    Lequesne, Justine

    2013-08-01

    Goodness-of-fit tests based on entropy have been introduced in [13] for testing normality. The maximum entropy distribution in a class of probability distributions defined by linear constraints induces a Pythagorean equality between the Kullback-Leibler information and an entropy difference. This allows one to propose a goodness-of-fit test for maximum entropy parametric distributions which is based on the Kullback-Leibler information. We will focus on the application of the method to the Pareto distribution. The power of the proposed test is computed through Monte Carlo simulation.

  12. Fecal Immunochemical Test (FIT) for Colon Cancer Screening: Variable Performance with Ambient Temperature

    PubMed Central

    Doubeni, Chyke A.; Jensen, Christopher D.; Fedewa, Stacey A.; Quinn, Virginia P.; Zauber, Ann G.; Schottinger, Joanne E.; Corley, Douglas A.; Levin, Theodore R.

    2017-01-01

    Introduction Fecal immunochemical tests (FITs) are widely used in colorectal cancer (CRC) screening, but hemoglobin degradation, due to exposure of the collected sample to high temperatures, could reduce test sensitivity. We examined the relation of ambient temperature exposure with FIT positivity rate and sensitivity. Methods This was a retrospective cohort study of patients 50 to 75 years in Kaiser Permanente Northern California’s CRC screening program, which began mailing FIT kits annually to screen-eligible members in 2007. Primary outcomes were FIT positivity rate and sensitivity to detect CRC. Predictors were month, season, and daily ambient temperatures of test result dates based on US National Oceanic and Atmospheric Administration data. Results Patients (n =472,542) completed 1,141,162 FITs. Weekly test positivity rate ranged from 2.6% to 8.0% (median, 4.4%) and varied significantly by month (June/July vs December/January rate ratio [RR] =0.79, 95% confidence interval [CI], 0.76 to 0.83) and season. FIT sensitivity was lower in June/July (74.5%; 95% CI, 72.5 to 76.6) than January/December (78.9%; 95% CI, 77.0 to 80.7). Conclusions FITs completed during high ambient temperatures had lower positivity rates and lower sensitivity. Changing kit design, specimen transportation practices, or avoiding periods of high ambient temperatures may help optimize FIT performance, but may also increase testing complexity and reduce patient adherence, requiring careful study. PMID:28076249

  13. A Label-Free, Quantitative Fecal Hemoglobin Detection Platform for Colorectal Cancer Screening

    PubMed Central

    Soraya, Gita V.; Nguyen, Thanh C.; Abeyrathne, Chathurika D.; Huynh, Duc H.; Chan, Jianxiong; Nguyen, Phuong D.; Nasr, Babak; Chana, Gursharan; Kwan, Patrick; Skafidas, Efstratios

    2017-01-01

    The early detection of colorectal cancer is vital for disease management and patient survival. Fecal hemoglobin detection is a widely-adopted method for screening and early diagnosis. Fecal Immunochemical Test (FIT) is favored over the older generation chemical based Fecal Occult Blood Test (FOBT) as it does not require dietary or drug restrictions, and is specific to human blood from the lower digestive tract. To date, no quantitative FIT platforms are available for use in the point-of-care setting. Here, we report proof of principle data of a novel low cost quantitative fecal immunochemical-based biosensor platform that may be further developed into a point-of-care test in low-resource settings. The label-free prototype has a lower limit of detection (LOD) of 10 µg hemoglobin per gram (Hb/g) of feces, comparable to that of conventional laboratory based quantitative FIT diagnostic systems. PMID:28475117

  14. Development of protocols for confined extension/creep testing of geosynthetics for highway applications

    DOT National Transportation Integrated Search

    1998-03-01

    This report presents the development and verification of a testing protocol and protocol equipment for confined extension testing and confined creep testing for geosynthetic reinforcement materials. The developed data indicate that confined response ...

  15. QTest: Quantitative Testing of Theories of Binary Choice.

    PubMed

    Regenwetter, Michel; Davis-Stober, Clintin P; Lim, Shiau Hong; Guo, Ying; Popova, Anna; Zwilling, Chris; Cha, Yun-Shil; Messner, William

    2014-01-01

    The goal of this paper is to make modeling and quantitative testing accessible to behavioral decision researchers interested in substantive questions. We provide a novel, rigorous, yet very general, quantitative diagnostic framework for testing theories of binary choice. This permits the nontechnical scholar to proceed far beyond traditionally rather superficial methods of analysis, and it permits the quantitatively savvy scholar to triage theoretical proposals before investing effort into complex and specialized quantitative analyses. Our theoretical framework links static algebraic decision theory with observed variability in behavioral binary choice data. The paper is supplemented with a custom-designed public-domain statistical analysis package, the QTest software. We illustrate our approach with a quantitative analysis using published laboratory data, including tests of novel versions of "Random Cumulative Prospect Theory." A major asset of the approach is the potential to distinguish decision makers who have a fixed preference and commit errors in observed choices from decision makers who waver in their preferences.

  16. QTest: Quantitative Testing of Theories of Binary Choice

    PubMed Central

    Regenwetter, Michel; Davis-Stober, Clintin P.; Lim, Shiau Hong; Guo, Ying; Popova, Anna; Zwilling, Chris; Cha, Yun-Shil; Messner, William

    2014-01-01

    The goal of this paper is to make modeling and quantitative testing accessible to behavioral decision researchers interested in substantive questions. We provide a novel, rigorous, yet very general, quantitative diagnostic framework for testing theories of binary choice. This permits the nontechnical scholar to proceed far beyond traditionally rather superficial methods of analysis, and it permits the quantitatively savvy scholar to triage theoretical proposals before investing effort into complex and specialized quantitative analyses. Our theoretical framework links static algebraic decision theory with observed variability in behavioral binary choice data. The paper is supplemented with a custom-designed public-domain statistical analysis package, the QTest software. We illustrate our approach with a quantitative analysis using published laboratory data, including tests of novel versions of “Random Cumulative Prospect Theory.” A major asset of the approach is the potential to distinguish decision makers who have a fixed preference and commit errors in observed choices from decision makers who waver in their preferences. PMID:24999495

  17. Eliciting improved quantitative judgements using the IDEA protocol: A case study in natural resource management.

    PubMed

    Hemming, Victoria; Walshe, Terry V; Hanea, Anca M; Fidler, Fiona; Burgman, Mark A

    2018-01-01

    Natural resource management uses expert judgement to estimate facts that inform important decisions. Unfortunately, expert judgement is often derived by informal and largely untested protocols, despite evidence that the quality of judgements can be improved with structured approaches. We attribute the lack of uptake of structured protocols to the dearth of illustrative examples that demonstrate how they can be applied within pressing time and resource constraints, while also improving judgements. In this paper, we demonstrate how the IDEA protocol for structured expert elicitation may be deployed to overcome operational challenges while improving the quality of judgements. The protocol was applied to the estimation of 14 future abiotic and biotic events on the Great Barrier Reef, Australia. Seventy-six participants with varying levels of expertise related to the Great Barrier Reef were recruited and allocated randomly to eight groups. Each participant provided their judgements using the four-step question format of the IDEA protocol ('Investigate', 'Discuss', 'Estimate', 'Aggregate') through remote elicitation. When the events were realised, the participant judgements were scored in terms of accuracy, calibration and informativeness. The results demonstrate that the IDEA protocol provides a practical, cost-effective, and repeatable approach to the elicitation of quantitative estimates and uncertainty via remote elicitation. We emphasise that i) the aggregation of diverse individual judgements into pooled group judgments almost always outperformed individuals, and ii) use of a modified Delphi approach helped to remove linguistic ambiguity, and further improved individual and group judgements. Importantly, the protocol encourages review, critical appraisal and replication, each of which is required if judgements are to be used in place of data in a scientific context. The results add to the growing body of literature that demonstrates the merit of using structured

  18. Fitness for duty: a 3-minute version of the Psychomotor Vigilance Test predicts fatigue-related declines in luggage-screening performance.

    PubMed

    Basner, Mathias; Rubinstein, Joshua

    2011-10-01

    To evaluate the ability of a 3-minute Psychomotor Vigilance Test (PVT) to predict fatigue-related performance decrements on a simulated luggage-screening task (SLST). Thirty-six healthy nonprofessional subjects (mean age = 30.8 years, 20 women) participated in a 4-day laboratory protocol including a 34-hour period of total sleep deprivation with PVT and SLST testing every 2 hours. Eleven and 20 lapses (355-ms threshold) on the PVT optimally divided SLST performance into high-, medium-, and low-performance bouts with significantly decreasing threat detection performance A'. Assignment to the different SLST performance groups replicated homeostatic and circadian patterns during total sleep deprivation. The 3-minute PVT was able to predict performance on a simulated luggage-screening task. Fitness-for-duty feasibility should now be tested in professional screeners and operational environments.

  19. First State Fitness Test. A Measurement of Functional Health.

    ERIC Educational Resources Information Center

    Brown, Timothy; And Others

    This test is designed to measure the functional health of young people. Functional health refers to those factors relating to personal health that can be improved with regular exercise. This test is unique in comparison to other physical fitness tests because of the absence of motor skill items which have no relationship to an individual's…

  20. Handling nonnormality and variance heterogeneity for quantitative sublethal toxicity tests.

    PubMed

    Ritz, Christian; Van der Vliet, Leana

    2009-09-01

    The advantages of using regression-based techniques to derive endpoints from environmental toxicity data are clear, and slowly, this superior analytical technique is gaining acceptance. As use of regression-based analysis becomes more widespread, some of the associated nuances and potential problems come into sharper focus. Looking at data sets that cover a broad spectrum of standard test species, we noticed that some model fits to data failed to meet two key assumptions-variance homogeneity and normality-that are necessary for correct statistical analysis via regression-based techniques. Failure to meet these assumptions often is caused by reduced variance at the concentrations showing severe adverse effects. Although commonly used with linear regression analysis, transformation of the response variable only is not appropriate when fitting data using nonlinear regression techniques. Through analysis of sample data sets, including Lemna minor, Eisenia andrei (terrestrial earthworm), and algae, we show that both the so-called Box-Cox transformation and use of the Poisson distribution can help to correct variance heterogeneity and nonnormality and so allow nonlinear regression analysis to be implemented. Both the Box-Cox transformation and the Poisson distribution can be readily implemented into existing protocols for statistical analysis. By correcting for nonnormality and variance heterogeneity, these two statistical tools can be used to encourage the transition to regression-based analysis and the depreciation of less-desirable and less-flexible analytical techniques, such as linear interpolation.

  1. Indices of Abdominal Adiposity and Cardiorespiratory Fitness Test Performance in Middle-School Students

    PubMed Central

    Burns, Ryan; Hannon, James C.; Brusseau, Timothy A.; Shultz, Barry; Eisenman, Patricia

    2013-01-01

    Background. Previous research suggests that use of BMI as a screening tool to assess health in youth has limitations. Valid alternative measures to assess body composition are needed to accurately identify children who are aerobically fit, which is an indicator of health status. The purpose of this study was to examine the associations between select anthropometric measures and cardiorespiratory fitness test performance in middle-school students. Methods. Participants included 134 students (65 boys and 69 girls) recruited from the 6th, 7th, and 8th grades. Anthropometric measures consisted of BMI, waist circumference (WC), waist-to-height ratio (WHtR), and percent body fat estimated from two-site skinfolds (%BF-SKF), as well as the hand-held OMRON BIA device (%BF-BIA). Cardiorespiratory fitness tests included the one-mile run and PACER test. Data were collected on four separate testing days during the students' physical education classes. Results. There were statistically significant moderate correlations between the %BF estimations, WHtR, and cardiorespiratory fitness test scores in both genders (P < .001). BMI at best only displayed weak correlations with the cardiorespiratory fitness test scores. Conclusions. The results suggest that alternative measures such as %BF-SKF, %BF-BIA, and WHtR may be more valid indicators of youth aerobic fitness lending to their preferred use over BMI. PMID:23533727

  2. Masonry fireplace emissions test method: Repeatability and sensitivity to fueling protocol.

    PubMed

    Stern, C H; Jaasma, D R; Champion, M R

    1993-03-01

    A test method for masonry fireplaces has been evaluated during testing on six masonry fireplace configurations. The method determines carbon monoxide and particulate matter emission rates (g/h) and factors (g/kg) and does not require weighing of the appliance to determine the timing of fuel loading.The intralaboratory repeatability of the test method has been determined from multiple tests on the six fireplaces. For the tested fireplaces, the ratio of the highest to lowest measured PM rate averaged 1.17 and in no case was greater than 1.32. The data suggest that some of the variation is due to differences in fuel properties.The influence of fueling protocol on emissions has also been studied. A modified fueling protocol, tested in large and small fireplaces, reduced CO and PM emission factors by roughly 40% and reduced CO and PM rates from 0 to 30%. For both of these fireplaces, emission rates were less sensitive to fueling protocol than emission factors.

  3. Full-scale tank car rollover tests - survivability of top fittings and top fittings protective structures : final report.

    DOT National Transportation Integrated Search

    2016-05-01

    Full-scale rollover crash tests were performed on three non-pressure tank carbodies to validate previous analytical work and : determine the effectiveness of two different types of protective structures in protecting the top fittings. The tests were ...

  4. Functional Fitness Testing Results Following Long-Duration ISS Missions.

    PubMed

    Laughlin, Mitzi S; Guilliams, Mark E; Nieschwitz, Bruce A; Hoellen, David

    2015-12-01

    Long-duration spaceflight missions lead to the loss of muscle strength and endurance. Significant reduction in muscle function can be hazardous when returning from spaceflight. To document these losses, NASA developed medical requirements that include measures of functional strength and endurance. Results from this Functional Fitness Test (FFT) battery are also used to evaluate the effectiveness of in-flight exercise countermeasures. The purpose of this paper is to document results from the FFT and correlate this information with performance of in-flight exercise on board the International Space Station. The FFT evaluates muscular strength and endurance, flexibility, and agility and includes the following eight measures: sit and reach, cone agility, push-ups, pull-ups, sliding crunches, bench press, leg press, and hand grip dynamometry. Pre- to postflight functional fitness measurements were analyzed using dependent t-tests and correlation analyses were used to evaluate the relationship between functional fitness measurements and in-flight exercise workouts. Significant differences were noted post space flight with the sit and reach, cone agility, leg press, and hand grip measurements while other test scores were not significantly altered. The relationships between functional fitness and in-flight exercise measurements showed minimal to moderate correlations for most in-flight exercise training variables. The change in FFT results can be partially explained by in-flight exercise performance. Although there are losses documented in the FFT results, it is important to realize that the crewmembers are successfully performing activities of daily living and are considered functional for normal activities upon return to Earth.

  5. Development of UV Testing Protocol and Recommendations

    EPA Science Inventory

    The goal of this effort is to develop and present new protocols for UV validation testing and analysis that leverage advances and may help to improve implementation and operation at PWSs. This document also provides for updated clarifications to the UVDGM based on evolving practi...

  6. Quantitative reactive modeling and verification.

    PubMed

    Henzinger, Thomas A

    Formal verification aims to improve the quality of software by detecting errors before they do harm. At the basis of formal verification is the logical notion of correctness , which purports to capture whether or not a program behaves as desired. We suggest that the boolean partition of software into correct and incorrect programs falls short of the practical need to assess the behavior of software in a more nuanced fashion against multiple criteria. We therefore propose to introduce quantitative fitness measures for programs, specifically for measuring the function, performance, and robustness of reactive programs such as concurrent processes. This article describes the goals of the ERC Advanced Investigator Project QUAREM. The project aims to build and evaluate a theory of quantitative fitness measures for reactive models. Such a theory must strive to obtain quantitative generalizations of the paradigms that have been success stories in qualitative reactive modeling, such as compositionality, property-preserving abstraction and abstraction refinement, model checking, and synthesis. The theory will be evaluated not only in the context of software and hardware engineering, but also in the context of systems biology. In particular, we will use the quantitative reactive models and fitness measures developed in this project for testing hypotheses about the mechanisms behind data from biological experiments.

  7. Approach-Avoidance Motivational Profiles in Early Adolescents to the PACER Fitness Test

    ERIC Educational Resources Information Center

    Garn, Alex; Sun, Haichun

    2009-01-01

    The use of fitness testing is a practical means for measuring components of health-related fitness, but there is currently substantial debate over the motivating effects of these tests. Therefore, the purpose of this study was to examine the cross-fertilization of achievement and friendship goal profiles for early adolescents involved in the…

  8. Incompleteness of Bluetooth protocol conformance test cases

    NASA Astrophysics Data System (ADS)

    Wu, Peng; Gao, Qiang

    2001-10-01

    This paper describes a formal method to verify the completeness of conformance testing, in which not only Implementation Under Test (IUT) is formalized in SDL, but also conformance tester is described in SDL so that conformance testing can be performed in simulator provided with CASE tool. The protocol set considered is Bluetooth, an open wireless communication technology. Our research results show that Bluetooth conformance test specification is not complete in that it has only limited coverage and many important capabilities defined in Bluetooth core specification are not tested. We also give a detail report on the missing test cases against Bluetooth core specification, and provide a guide on further test case generation in the future.

  9. Review of Motor Development, Perceptual-Motor and Physical Fitness Testing.

    ERIC Educational Resources Information Center

    Bundschuh, Ernest; And Others

    Tests of motor development, perceptual-motor coordination, and physical fitness, for the retarded and non-retarded, are reviewed regarding their usage and administration. The tests reviewed are the: Denver Developmental Screening Test, Bayley Scales of Infant Development, Dayton Sensory Motor Awareness Survey, Minnetonka Physical Performance…

  10. Prevalence and Correlates of Physical Fitness Testing in U.S. Schools--2000

    ERIC Educational Resources Information Center

    Morrow, James R., Jr.; Fulton, Janet E.; Brener, Nancy D.; Kohl, Harold W., III

    2008-01-01

    Because of the perceived lack of youth physical fitness and/or concerns for increased obesity, physical education teachers are interested in youth fitness and physical activity levels. Statewide mandates are being developed that require school-based teachers to complete physical fitness testing. Data from the nationally representative School…

  11. Investigation of prefrontal cerebral hemodynamics during quantitative autonomic testing using NIRS (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Phillips, Zephaniah; Paik, Seung-Ho; Kim, Yoohwan; Kim, Byung-Jo; Choi, Youngwoon; Kim, Beop-Min

    2017-02-01

    In this work, we analyzed the clinical applicability of NIRS for use during Quantitative Autonomic Testing (QAT). QAT is a protocol consisting of deep breathing, Valsalva maneuver, and tilt table examination. It is used to diagnose a patient with disorders of the autonomic nervous system (ANS). Disorders of ANS includes orthostatic hyper/hypotension, vasovagal syncope, and postural orthostatic tachycardia syndrome. The results of QAT are typically analyzed with the use of blood pressure and heart rate data, however these metrics may be influenced by factors such as arrhythmia, making the data interpretation and diagnosis difficult for clinicians. We tested our custom built 108-channel NIRS probe on 26 elderly patients during the QAT protocol with various ANS disorders. We found that prefrontal cerebral oxygenation correlated well with blood pressure and heart rate changes for all three tasks, making it a clinically feasible tool for observing ANS functionality. During the Valsalva maneuver, we observed a longer delayed and lower amplitude response of cerebral oxygenation to the prefrontal area in orthostatic intolerant patients. During the tilt table examination, we saw a larger response in cerebral oxygenation and less equal transient cerebral oxygenation during tilt up and tilt down in tilt table examinations that were positive (unhealthy), compared to tilt table examinations that were negative (healthy). Overall, our study showcases NIRS as an enhanced tool for understanding ANS disorders.

  12. Improving health-related fitness in children: the Fit-4-Fun randomized controlled trial study protocol.

    PubMed

    Eather, Narelle; Morgan, Philip J; Lubans, David R

    2011-12-05

    Declining levels of physical fitness in children are linked to an increased risk of developing poor physical and mental health. Physical activity programs for children that involve regular high intensity physical activity, along with muscle and bone strengthening activities, have been identified by the World Health Organisation as a key strategy to reduce the escalating burden of ill health caused by non-communicable diseases. This paper reports the rationale and methods for a school-based intervention designed to improve physical fitness and physical activity levels of Grades 5 and 6 primary school children. Fit-4-Fun is an 8-week multi-component school-based health-related fitness education intervention and will be evaluated using a group randomized controlled trial. Primary schools from the Hunter Region in NSW, Australia, will be invited to participate in the program in 2011 with a target sample size of 128 primary schools children (age 10-13). The Fit-4-Fun program is theoretically grounded and will be implemented applying the Health Promoting Schools framework. Students will participate in weekly curriculum-based health and physical education lessons, daily break-time physical activities during recess and lunch, and will complete an 8-week (3 × per week) home activity program with their parents and/or family members. A battery of six health-related fitness assessments, four days of pedometery-assessed physical activity and a questionnaire, will be administered at baseline, immediate post-intervention (2-months) and at 6-months (from baseline) to determine intervention effects. Details of the methodological aspects of recruitment, inclusion criteria, randomization, intervention program, assessments, process evaluation and statistical analyses are described. The Fit-4-Fun program is an innovative school-based intervention targeting fitness improvements in primary school children. The program will involve a range of evidence-based behaviour change strategies to

  13. Improving health-related fitness in children: the fit-4-Fun randomized controlled trial study protocol

    PubMed Central

    2011-01-01

    Background Declining levels of physical fitness in children are linked to an increased risk of developing poor physical and mental health. Physical activity programs for children that involve regular high intensity physical activity, along with muscle and bone strengthening activities, have been identified by the World Health Organisation as a key strategy to reduce the escalating burden of ill health caused by non-communicable diseases. This paper reports the rationale and methods for a school-based intervention designed to improve physical fitness and physical activity levels of Grades 5 and 6 primary school children. Methods/Design Fit-4-Fun is an 8-week multi-component school-based health-related fitness education intervention and will be evaluated using a group randomized controlled trial. Primary schools from the Hunter Region in NSW, Australia, will be invited to participate in the program in 2011 with a target sample size of 128 primary schools children (age 10-13). The Fit-4-Fun program is theoretically grounded and will be implemented applying the Health Promoting Schools framework. Students will participate in weekly curriculum-based health and physical education lessons, daily break-time physical activities during recess and lunch, and will complete an 8-week (3 × per week) home activity program with their parents and/or family members. A battery of six health-related fitness assessments, four days of pedometery-assessed physical activity and a questionnaire, will be administered at baseline, immediate post-intervention (2-months) and at 6-months (from baseline) to determine intervention effects. Details of the methodological aspects of recruitment, inclusion criteria, randomization, intervention program, assessments, process evaluation and statistical analyses are described. Discussion The Fit-4-Fun program is an innovative school-based intervention targeting fitness improvements in primary school children. The program will involve a range of evidence

  14. The CAHPER Fitness-Performance Test Manual: For Boys and Girls 7 to 17 Years of Age.

    ERIC Educational Resources Information Center

    Canadian Association for Health, Physical Education, and Recreation, Ottawa (Ontario).

    Outlined in this manual is Canada's first National Test of Physical Fitness. Each test item is a valid and reliable measure of fitness, simple enough for any teacher not trained in fitness measurement to administer. Each of the six tests measures a different aspect of fitness: (1) the one-minute speed sit-up tests the strength and endurance of the…

  15. The effect of bone tunnel dilation versus extraction drilling on the initial fixation strength of press-fit anterior cruciate ligament reconstruction.

    PubMed

    Dargel, Jens; Schmidt-Wiethoff, Rüdiger; Brüggemann, Gert-Peter; Koebke, Jürgen

    2007-11-01

    Serial dilation of the bone tunnel has been reported to create a tighter graft-tunnel fit. It was hypothesized that a serial dilation of the femoral bone tunnel would increase the initial fixation strength in press-fit anterior cruciate ligament (ACL) reconstructive surgery. Initial fixation strength of the femoral press-fit fixation technique was investigated in 72 porcine specimens in an ex vivo study by varying the femoral tunnel preparation technique. Extraction-drilling, tunnel dilation by 1 mm and dilation by 2.5 mm were assessed. Initial fixation strength of press-fit fixated patellar tendon-bone grafts was tested within each preparation group conducting a single cycle (and cyclic) load to failure protocol. The resulting tunnel diameter and the porcine femoral bone mineral density were determined using microradiographs and peripheral quantitative CT scans, respectively. Dilating a previously extraction-drilled femoral bone tunnel by 1 mm significantly enhances initial press-fit fixation strength in both single cycle and cyclic load to failure testing when compared to extraction-drilling and tunnel dilation by 2.5 mm. Due to an initial spring-back effect the resulting diameter of the femoral tunnel was underestimated by 3.3% with drilling and 6.7 and 12.2% with dilation by 1 and 2.5 mm, respectively. Volumetric trabecular bone mineral density at the site corresponding to the area of tunnel placement averaged 318 mg/cm(3). Dilating a femoral tunnel that is underdrilled by 1 mm appears to be a reasonable technical procedure in order to enhance initial fixation strength of press-fit ACL graft fixation.

  16. Determinants of Teacher Implementation of Youth Fitness Tests in School-Based Physical Education Programs

    ERIC Educational Resources Information Center

    Keating, Xiaofen Deng; Silverman, Stephen

    2009-01-01

    Background: Millions of American children are participating in fitness testing in school-based physical education (PE) programs. However, practitioners and researchers in the field of PE have questioned the need for regular or mandatory youth fitness testing. This was partly because a significant improvement in youth fitness and physical activity…

  17. Press-fit acetabular cup fixation: principles and testing.

    PubMed

    Macdonald, W; Carlsson, L V; Charnley, G J; Jacobsson, C M

    1999-01-01

    Pre-clinical testing of the fixation of press-fit acetabular components of total hip prostheses relies on cadaver or synthetic bone, but the properties and geometry of bone models differ from those of physiological bone. Cup designs use varied mechanisms for initial stability in bone; therefore, using different analogues and tests is appropriate. Press-fit cup stability was tested in the following: firstly, polyurethane (PU) foam modelling cancellous support; secondly, glass-fibre reinforced epoxide (GFRE) tubes modelling acetabular cortical support; thirdly, cadaveric acetabula. Three commercial cups [Harris-Galante II (H-G-II), Zimmer; Optifix, Smith & Nephew, Richards; porous coated anatomic (PCA), Howmedica] and an experimental cup with enhanced rim fixation were tested in three modes: direct pull-out, lever-out and axial torque. The fixation stabilities measured in the PU and the GFRE models showed trends consistent with those in cadaver bone, differing in the oversizing and cup geometry. The experimental cup was significantly more secure in most modes than other cups; the H-G II and Optifix cups showed similar stabilities, lower than that of the experimental cup but greater than that of the PCA cup (analysis of variance and Tukey's highly significant test; p < 0.001). The stabilities measured in cadaver bone more closely approximated those in GFRE. The use of several bone analogues enables separation of fixation mechanisms, allowing more accurate prediction of in vivo performance.

  18. Reference Curves for Field Tests of Musculoskeletal Fitness in U.S. Children and Adolescents: The 2012 NHANES National Youth Fitness Survey.

    PubMed

    Laurson, Kelly R; Saint-Maurice, Pedro F; Welk, Gregory J; Eisenmann, Joey C

    2017-08-01

    Laurson, KR, Saint-Maurice, PF, Welk, GJ, and Eisenmann, JC. Reference curves for field tests of musculoskeletal fitness in U.S. children and adolescents: The 2012 NHANES National Youth Fitness Survey. J Strength Cond Res 31(8): 2075-2082, 2017-The purpose of the study was to describe current levels of musculoskeletal fitness (MSF) in U.S. youth by creating nationally representative age-specific and sex-specific growth curves for handgrip strength (including relative and allometrically scaled handgrip), modified pull-ups, and the plank test. Participants in the National Youth Fitness Survey (n = 1,453) were tested on MSF, aerobic capacity (via submaximal treadmill test), and body composition (body mass index [BMI], waist circumference, and skinfolds). Using LMS regression, age-specific and sex-specific smoothed percentile curves of MSF were created and existing percentiles were used to assign age-specific and sex-specific z-scores for aerobic capacity and body composition. Correlation matrices were created to assess the relationships between z-scores on MSF, aerobic capacity, and body composition. At younger ages (3-10 years), boys scored higher than girls for handgrip strength and modified pull-ups, but not for the plank. By ages 13-15, differences between the boys and girls curves were more pronounced, with boys scoring higher on all tests. Correlations between tests of MSF and aerobic capacity were positive and low-to-moderate in strength. Correlations between tests of MSF and body composition were negative, excluding absolute handgrip strength, which was inversely related to other MSF tests and aerobic capacity but positively associated with body composition. The growth curves herein can be used as normative reference values or a starting point for creating health-related criterion reference standards for these tests. Comparisons with prior national surveys of physical fitness indicate that some components of MSF have likely decreased in the United States over

  19. Cardiorespiratory Fitness Change and Mortality Risk Among Black and White Patients: Henry Ford Exercise Testing (FIT) Project.

    PubMed

    Ehrman, Jonathan K; Brawner, Clinton A; Al-Mallah, Mouaz H; Qureshi, Waqas T; Blaha, Michael J; Keteyian, Steven J

    2017-10-01

    Little is known about the relationship of change in cardiorespiratory fitness and mortality risk in Black patients. This study assessed change in cardiorespiratory fitness and its association with all-cause mortality risk in Black and White patients. This is a retrospective, longitudinal, observational cohort study of 13,345 patients (age = 55 ± 11 years; 39% women; 26% black) who completed 2 exercise tests, at least 12 months apart at Henry Ford Hospital, Detroit, Mich. All-cause mortality was identified through April 2013. Data were analyzed in 2015-2016 using Cox regression to calculate hazard ratios (HR) for risk of mortality associated with change in sex-specific cardiorespiratory fitness. Mean time between the tests was 3.4 years (interquartile range 1.9-5.6 years). During 9.1 years (interquartile range 6.3-11.6 years) of follow-up, there were 1931 (14%) deaths (16.5% black, 13.7% white). For both races, change in fitness from Low to the Intermediate/High category resulted in a significant reduction of death risk (HR 0.65 [95% confidence interval (CI), 0.49-0.87] for Black; HR 0.41 [95% CI, 0.34-0.51] for White). Each 1-metabolic-equivalent-of-task increase was associated with a reduced mortality risk in black (HR 0.84 [95% CI, 0.81-0.89]) and white (HR 0.87 [95% CI, 0.82-0.86]) patients. There was no interaction by race. Among black and white patients, change in cardiorespiratory fitness from Low to Intermediate/High fitness was associated with a 35% and 59% lower risk of all-cause mortality, respectively. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Person Fit Analysis in Computerized Adaptive Testing Using Tests for a Change Point

    ERIC Educational Resources Information Center

    Sinharay, Sandip

    2016-01-01

    Meijer and van Krimpen-Stoop noted that the number of person-fit statistics (PFSs) that have been designed for computerized adaptive tests (CATs) is relatively modest. This article partially addresses that concern by suggesting three new PFSs for CATs. The statistics are based on tests for a change point and can be used to detect an abrupt change…

  1. Fitness for duty: A 3 minute version of the Psychomotor Vigilance Test predicts fatigue related declines in luggage screening performance

    PubMed Central

    Basner, Mathias; Rubinstein, Joshua

    2011-01-01

    Objective To evaluate the ability of a 3-min Psychomotor Vigilance Test (PVT) to predict fatigue related performance decrements on a simulated luggage screening task (SLST). Methods Thirty-six healthy non-professional subjects (mean age 30.8 years, 20 female) participated in a 4 day laboratory protocol including a 34 hour period of total sleep deprivation with PVT and SLST testing every 2 hours. Results Eleven and 20 lapses (355 ms threshold) on the PVT optimally divided SLST performance into high, medium, and low performance bouts with significantly decreasing threat detection performance A′. Assignment to the different SLST performance groups replicated homeostatic and circadian patterns during total sleep deprivation. Conclusions The 3 min PVT was able to predict performance on a simulated luggage screening task. Fitness-for-duty feasibility should now be tested in professional screeners and operational environments. PMID:21912278

  2. Evaluation of Criteria Associated with Abdominal Fitness Testing.

    ERIC Educational Resources Information Center

    Robertson, Loarn D.; Magnusdottir, Hjordis

    1987-01-01

    The use of the timed sit up as a measure of abdominal fitness has been challenged. This article describes experiments designed to evaluate a modified curl up test as an alternative. Subjects were 20 college students averaging 25.3 years of age. Results are discussed. (Author/MT)

  3. Protocol for physical assessment in patients with fibromyalgia syndrome.

    PubMed

    dos Santos, Michele R; Moro, Claudia M C; Vosgerau, Dilmeire S R

    2014-01-01

    Fibromyalgia syndrome (FMS) is a chronic disease that causes pain and fatigue, presenting a negative impact on quality of life. Exercise helps maintaining physical fitness and influences directly on the improvement of quality of life. Develop a protocol for health-related physical fitness assessment of patients with FMS with tests that are feasible and appropriate for this population. An exploratory and analytical literature review was performed, seeking to determine the tests used by the scientific community. With this in mind, we performed a literature revision through the use of virtual libraries databases: PubMed, Bireme, Banco de Teses e Dissertações da Capes and Biblioteca Digital Brasileira de Teses e Dissertações, published in between 1992-2012. A variety of tests was found; the following, by number of citations, stood out: Body Mass Index (BMI) and bioimpedance; 6-minute walk; handgrip strength (dynamometer, 1RM [Repetition Maximum]); Sit and reach and Shoulder flexibility; Foot Up and Go, and Flamingo balance. These are the tests that should make up the protocol for the physical evaluation of FMS patients, emphasizing their ease of use.

  4. Effectiveness of three just-in-time training modalities for N-95 mask fit testing.

    PubMed

    Jones, David; Stoler, Genevieve; Suyama, Joe

    2013-01-01

    To compare and contrast three different training modalities for fit testing N-95 respirator face masks. Block randomized interventional study. Urban university. Two hundred eighty-nine medical students. Students were randomly assigned to video, lecture, or slide show to evaluate the effectiveness of the methods for fit testing large groups of people. Ease of fit and success of fit for each instructional technique. Mask 1 was a Kimberly-Clark duckbill N-95 respirator mask, and mask 2 was a 3M™ carpenters N-95 respirator mask. "Ease of fit" was defined as the ability to successfully don a mask in less than 30 seconds. "Success of fit" was defined as the ability to correctly don a mask in one try. There were no statistical differences by training modality for either mask regarding ease of fit or success of fit. There were no differences among video presentation, small group demonstration, and self-directed slide show just-in-time training modalities for ease of fit or success of fit N-95 respirator mask fitting. Further study is needed to explore more effective fit training modalities.

  5. Push-off tests and strength evaluation of joints combining shrink fitting with bonding

    NASA Astrophysics Data System (ADS)

    Yoneno, Masahiro; Sawa, Toshiyuki; Shimotakahara, Ken; Motegi, Yoichi

    1997-03-01

    Shrink fitted joints have been used in mechanical structures. Recently, joints combining shrink fitting with anaerobic adhesives bonded between the shrink fitted surfaces have been appeared in order to increase the joint strength. In this paper, push-off test was carried out on strength of joints combining shrink fitting with bonding by material testing machine. In addition, the push-off strength of shrink fitting joints without an anaerobic adhesive was also measured. In the experiments, the effects of the shrinking allowance and the outer diameter of the rings on the joint strength are examined. The interface stress distribution in bonded shrink fitted joints subjected to a push-off load is analyzed using axisymmetrical theory of elasticity as a four-body contact problem. Using the interface stress distribution, a method for estimating joint strength is proposed. The experimental results are in a fairly good agreement with the numerical results. It is found that the strength of combination joints is greater than that of shrink fitted joints.

  6. The Activity of Antimicrobial Surfaces Varies by Testing Protocol Utilized

    PubMed Central

    Campos, Matias D.; Zucchi, Paola C.; Phung, Ann; Leonard, Steven N.; Hirsch, Elizabeth B.

    2016-01-01

    Background Contaminated hospital surfaces are an important source of nosocomial infections. A major obstacle in marketing antimicrobial surfaces is a lack of efficacy data based on standardized testing protocols. Aim We compared the efficacy of multiple testing protocols against several “antimicrobial” film surfaces. Methods Four clinical isolates were used: one Escherichia coli, one Klebsiella pneumoniae, and two Staphylococcus aureus strains. Two industry methods (modified ISO 22196 and ASTM E2149), a “dried droplet”, and a “transfer” method were tested against two commercially available antimicrobial films, one film in development, an untreated control, and a positive (silver) control film. At 2 (only ISO) and 24 hours following inoculation, bacteria were collected from film surfaces and enumerated. Results Compared to untreated films in all protocols, there were no significant differences in recovery on either commercial brand at 2 or 24 hours after inoculation. The silver surface demonstrated significant microbicidal activity (mean loss 4.9 Log10 CFU/ml) in all methods and time points with the exception of 2 hours in the ISO protocol and the transfer method. Using our novel droplet method, no differences between placebo and active surfaces were detected. The surface in development demonstrated variable activity depending on method, organism, and time point. The ISO demonstrated minimal activity at 2 hours but significant activity at 24 hours (mean 4.5 Log10 CFU/ml difference versus placebo). The ASTEM protocol exhibited significant differences in recovery of staphylococci (mean 5 Log10 CFU/ml) but not Gram-negative isolates (10 fold decrease). Minimal activity was observed with this film in the transfer method. Conclusions Varying results between protocols suggested that efficacy of antimicrobial surfaces cannot be easily and reproducibly compared. Clinical use should be considered and further development of representative methods is needed. PMID

  7. Sport-Specific Motor Fitness Tests in Water Polo: Reliability, Validity and Playing Position Differences

    PubMed Central

    Uljevic, Ognjen; Spasic, Miodrag; Sekulic, Damir

    2013-01-01

    Sport-specific motor fitness tests are not often examined in water polo. In this study we examined the reliability, factorial and discriminative validity of 10 water-polo-specific motor-fitness tests, namely: three tests of in-water jumps (thrusts), two characteristic swimming sprints (10 and 20 metres from the water start), three ball-throws (shoots), one test of passing precision (accuracy), and a test of the dynamometric force produced while using the eggbeater kick. The sample of subjects consisted of 54 young male water polo players (15 to 17 years of age; 1.86 ± 0.07 m, and 83.1 ± 9.9 kg). All tests were applied over three testing trials. Reliability analyses included Cronbach Alpha coefficients (CA), inter-item- correlations (IIR) and coefficients of the variation (CV), while an analysis of variance was used to define any systematic bias between the testing trials. All tests except the test of accuracy (precision) were found to be reliable (CA ranged from 0.83 to 0.97; IIR from 0.62 to 0.91; CV from 2% to 21%); with small and irregular biases between the testing trials. Factor analysis revealed that jumping capacities as well as throwing and sprinting capacities should be observed as a relatively independent latent dimensions among young water polo players. Discriminative validity of the applied tests is partially proven since the playing positions significantly (p < 0.05) differed in some of the applied tests, with the points being superior in their fitness capacities in comparison to their teammates. This study included players from one of the world’s best junior National leagues, and reported values could be used as fitness standards for such an age. Further studies are needed to examine the applicability of the proposed test procedures to older subjects and females. Key Points Here presented and validated sport specific water polo motor fitness tests are found to be reliable in the sample of young male water polo players. Factor analysis revealed

  8. Prototype ultrasonic instrument for quantitative testing

    NASA Technical Reports Server (NTRS)

    Lynnworth, L. C.; Dubois, J. L.; Kranz, P. R.

    1972-01-01

    A prototype ultrasonic instrument has been designed and developed for quantitative testing. The complete delivered instrument consists of a pulser/receiver which plugs into a standard oscilloscope, an rf power amplifier, a standard decade oscillator, and a set of broadband transducers for typical use at 1, 2, 5 and 10 MHz. The system provides for its own calibration, and on the oscilloscope, presents a quantitative (digital) indication of time base and sensitivity scale factors and some measurement data.

  9. Feasibility and Reliability of Physical Fitness Tests in Older Adults with Intellectual Disability: A Pilot Study

    ERIC Educational Resources Information Center

    Hilgenkamp, Thessa I. M.; van Wijck, Ruud; Evenhuis, Heleen M.

    2012-01-01

    Background: Physical fitness is relevant for wellbeing and health, but knowledge on the feasibility and reliability of instruments to measure physical fitness for older adults with intellectual disability is lacking. Methods: Feasibility and test-retest reliability of a physical fitness test battery (Box and Block Test, Response Time Test, walking…

  10. Tests of Fit for Asymmetric Laplace Distributions with Applications on Financial Data

    NASA Astrophysics Data System (ADS)

    Fragiadakis, Kostas; Meintanis, Simos G.

    2008-11-01

    New goodness-of-fit tests for the family of asymmetric Laplace distributions are constructed. The proposed tests are based on a weighted integral incorporating the empirical characteristic function of suitably standardized data, and can be written in a closed form appropriate for computer implementation. Monte Carlo results show that the new procedure are competitive with classical goodness-of-fit methods. Applications with financial data are also included.

  11. A Person Fit Test for IRT Models for Polytomous Items

    ERIC Educational Resources Information Center

    Glas, C. A. W.; Dagohoy, Anna Villa T.

    2007-01-01

    A person fit test based on the Lagrange multiplier test is presented for three item response theory models for polytomous items: the generalized partial credit model, the sequential model, and the graded response model. The test can also be used in the framework of multidimensional ability parameters. It is shown that the Lagrange multiplier…

  12. Quantitative and qualitative comparison of MR imaging of the temporomandibular joint at 1.5 and 3.0 T using an optimized high-resolution protocol.

    PubMed

    Manoliu, Andrei; Spinner, Georg; Wyss, Michael; Erni, Stefan; Ettlin, Dominik A; Nanz, Daniel; Ulbrich, Erika J; Gallo, Luigi M; Andreisek, Gustav

    2016-01-01

    To quantitatively and qualitatively compare MRI of the temporomandibular joint (TMJ) using an optimized high-resolution protocol at 3.0 T and a clinical standard protocol at 1.5 T. A phantom and 12 asymptomatic volunteers were MR imaged using a 2-channel surface coil (standard TMJ coil) at 1.5 and 3.0 T (Philips Achieva and Philips Ingenia, respectively; Philips Healthcare, Best, Netherlands). Imaging protocol consisted of coronal and oblique sagittal proton density-weighted turbo spin echo sequences. For quantitative evaluation, a spherical phantom was imaged. Signal-to-noise ratio (SNR) maps were calculated on a voxelwise basis. For qualitative evaluation, all volunteers underwent MRI of the TMJ with the jaw in closed position. Two readers independently assessed visibility and delineation of anatomical structures of the TMJ and overall image quality on a 5-point Likert scale. Quantitative and qualitative measurements were compared between field strengths. The quantitative analysis showed similar SNR for the high-resolution protocol at 3.0 T compared with the clinical protocol at 1.5 T. The qualitative analysis showed significantly better visibility and delineation of clinically relevant anatomical structures of the TMJ, including the TMJ disc and pterygoid muscle as well as better overall image quality at 3.0 T than at 1.5 T. The presented results indicate that expected gains in SNR at 3.0 T can be used to increase the spatial resolution when imaging the TMJ, which translates into increased visibility and delineation of anatomical structures of the TMJ. Therefore, imaging at 3.0 T should be preferred over 1.5 T for imaging the TMJ.

  13. Test Protocols for Advanced Inverter Interoperability Functions – Main Document

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Jay Dean; Gonzalez, Sigifredo; Ralph, Mark E.

    2013-11-01

    Distributed energy resources (DER) such as photovoltaic (PV) systems, when deployed in a large scale, are capable of influencing significantly the operation of power systems. Looking to the future, stakeholders are working on standards to make it possible to manage the potentially complex interactions between DER and the power system. In 2009, the Electric Power Research Institute (EPRI), Sandia National Laboratories (SNL) with the U.S. Department of Energy (DOE), and the Solar Electric Power Association (SEPA) initiated a large industry collaborative to identify and standardize definitions for a set of DER grid support functions. While the initial effort concentrated onmore » grid-tied PV inverters and energy storage systems, the concepts have applicability to all DER. A partial product of this on-going effort is a reference definitions document (IEC TR 61850-90-7, Object models for power converters in distributed energy resources (DER) systems) that has become a basis for expansion of related International Electrotechnical Commission (IEC) standards, and is supported by US National Institute of Standards and Technology (NIST) Smart Grid Interoperability Panel (SGIP). Some industry-led organizations advancing communications protocols have also embraced this work. As standards continue to evolve, it is necessary to develop test protocols to independently verify that the inverters are properly executing the advanced functions. Interoperability is assured by establishing common definitions for the functions and a method to test compliance with operational requirements. This document describes test protocols developed by SNL to evaluate the electrical performance and operational capabilities of PV inverters and energy storage, as described in IEC TR 61850-90-7. While many of these functions are not currently required by existing grid codes or may not be widely available commercially, the industry is rapidly moving in that direction. Interoperability issues are

  14. Motivational Responses to Fitness Testing by Award Status and Gender

    ERIC Educational Resources Information Center

    Domangue, Elizabeth; Solmon, Melinda

    2010-01-01

    Fitness testing is a prominent element in many physical education programs, but there has been limited investigation concerning motivation constructs associated with the testing. This study investigated the relationships among physical education students' award status and gender to achievement goals, intrinsic motivation, and intentions. After…

  15. Evaluation of Aspergillus PCR protocols for testing serum specimens.

    PubMed

    White, P Lewis; Mengoli, Carlo; Bretagne, Stéphane; Cuenca-Estrella, Manuel; Finnstrom, Niklas; Klingspor, Lena; Melchers, Willem J G; McCulloch, Elaine; Barnes, Rosemary A; Donnelly, J Peter; Loeffler, Juergen

    2011-11-01

    A panel of human serum samples spiked with various amounts of Aspergillus fumigatus genomic DNA was distributed to 23 centers within the European Aspergillus PCR Initiative to determine analytical performance of PCR. Information regarding specific methodological components and PCR performance was requested. The information provided was made anonymous, and meta-regression analysis was performed to determine any procedural factors that significantly altered PCR performance. Ninety-seven percent of protocols were able to detect a threshold of 10 genomes/ml on at least one occasion, with 83% of protocols reproducibly detecting this concentration. Sensitivity and specificity were 86.1% and 93.6%, respectively. Positive associations between sensitivity and the use of larger sample volumes, an internal control PCR, and PCR targeting the internal transcribed spacer (ITS) region were shown. Negative associations between sensitivity and the use of larger elution volumes (≥100 μl) and PCR targeting the mitochondrial genes were demonstrated. Most Aspergillus PCR protocols used to test serum generate satisfactory analytical performance. Testing serum requires less standardization, and the specific recommendations shown in this article will only improve performance.

  16. Goodness-of-fit tests for open capture-recapture models

    USGS Publications Warehouse

    Pollock, K.H.; Hines, J.E.; Nichols, J.D.

    1985-01-01

    General goodness-of-fit tests for the Jolly-Seber model are proposed. These tests are based on conditional arguments using minimal sufficient statistics. The tests are shown to be of simple hypergeometric form so that a series of independent contingency table chi-square tests can be performed. The relationship of these tests to other proposed tests is discussed. This is followed by a simulation study of the power of the tests to detect departures from the assumptions of the Jolly-Seber model. Some meadow vole capture-recapture data are used to illustrate the testing procedure which has been implemented in a computer program available from the authors.

  17. An alternative to traditional goodness-of-fit tests for discretely measured continuous data

    Treesearch

    KaDonna C. Randolph; Bill Seaver

    2007-01-01

    Traditional goodness-of-fit tests such as the Kolmogorov-Smirnov and x2 tests are easily applied to data of the continuous or discrete type, respectively. Occasionally, however, the case arises when continuous data are recorded into discrete categories due to an imprecise measurement system. In this instance, the traditional goodness-of-fit...

  18. Population Screening for Colorectal Cancer Means Getting FIT: The Past, Present, and Future of Colorectal Cancer Screening Using the Fecal Immunochemical Test for Hemoglobin (FIT)

    PubMed Central

    Fraser, Callum G.; Halloran, Stephen P.; Young, Graeme P.

    2014-01-01

    Fecal immunochemical tests for hemoglobin (FIT) are changing the manner in which colorectal cancer (CRC) is screened. Although these tests are being performed worldwide, why is this test different from its predecessors? What evidence supports its adoption? How can this evidence best be used? This review addresses these questions and provides an understanding of FIT theory and practices to expedite international efforts to implement the use of FIT in CRC screening. PMID:24672652

  19. Best Protocol for the Sit-to-Stand Test in Subjects With COPD.

    PubMed

    Morita, Andrea A; Bisca, Gianna W; Machado, Felipe V C; Hernandes, Nidia A; Pitta, Fabio; Probst, Vanessa S

    2018-05-22

    Different protocols for the sit-to-stand test (STS) are available for assessing functional capacity in COPD. We sought to correlate each protocol of the STS (ie, the 5-repetition [5-rep STS], the 30-s STS, and the 1-min STS) with clinical outcomes in subjects with COPD. We also aimed to compare the 3 protocols of the STS, to verify their association and agreement, and to verify whether the 3 protocols are able to predict functional exercise capacity and physical activity in daily life (PADL). 23 subjects with COPD (11 men; FEV 1 53 ± 15% predicted) performed 3 protocols of the STS. Subjects also underwent the following assessments: incremental shuttle walking test, 6-min walk test (6MWT), 4-m gait speed test (4MGS), 1-repetition maximum of quadriceps muscle, assessment of PADL, and questionnaires on health-related quality of life and functional status. The 1-min STS showed significant correlations with the 6MWT (r = 0.40), 4MGS (r = 0.64), and PADL (0.40 ≤ r ≤ 0.52), and the 5-rep STS and 30-s STS were associated with the 4MGS (r = 0.54 and r = 0.52, respectively). The speed differed for each protocol (5-rep STS 0.53 ± 0.16 rep/s, 30-s STS 0.48 ± 0.13 rep/s, 1-min STS 0.45 ± 0.11 rep/s, P = .01). However, they presented good agreement (intraclass correlation coefficient ≥ 0.73 for all) and correlated well with each other (r ≥ 0.68 for all). More marked changes in peripheral oxygen saturation ( P = .004), heart rate ( P < .001), blood pressure ( P < .001), dyspnea ( P < .001), and leg fatigue ( P < .001) were found after the 1-min STS protocol. Furthermore, the 3 protocols were equally able to identify subjects with low exercise capacity or preserved exercise capacity. The 1-min STS generated higher hemodynamic demands and correlated better with clinical outcomes in subjects with COPD. Despite the difference in speed performance and physiological demands between the 5-rep STS and 1-min STS, there was a good level of agreement among the 3 protocols. In

  20. Comparison of intradermal dilutional testing, skin prick testing, and modified quantitative testing for common allergens.

    PubMed

    Peltier, Jacques; Ryan, Matthew W

    2007-08-01

    To compare and correlate wheal size using the Multi-Test II applicator with the endpoint obtained by intradermal dilutional testing (IDT) for 5 common allergens. To examine the safety of modified quantitative testing (MQT) for determining immunotherapy starting doses. Prospective comparative clinical study. A total of 134 subjects were simultaneously skin tested for immediate hypersensitivity using the Multi-Test II device and IDT. There was a 77% concordance between results from IDT and results from MQT. When there was a difference, MQT predicted a safer endpoint for starting immunotherapy in all but 2 cases. Wheal size by SPT is predictive of endpoint by IDT. MQT is nearly as effective as formal IDT in determining endpoint. Modified quantitative testing appears to be a safe alternative to IDT for determining starting doses for immunotherapy.

  1. Transitioning Adolescents and Young Adults With HIV Infection to Adult Care: Pilot Testing the "Movin' Out" Transitioning Protocol.

    PubMed

    Maturo, Donna; Powell, Alexis; Major-Wilson, Hannah; Sanchez, Kenia; De Santis, Joseph P; Friedman, Lawrence B

    2015-01-01

    Advances in care and treatment of adolescents/young adults with HIV infection have made survival into adulthood possible, requiring transition to adult care. Researchers have documented that the transition process is challenging for adolescents/young adults. To ensure successful transition, a formal transition protocol is needed. Despite existing research, little quantitative evaluation of the transition process has been conducted. The purpose of the study was to pilot test the "Movin' Out" Transitioning Protocol, a formalized protocol developed to assist transition to adult care. A retrospective medical/nursing record review was conducted with 38 clients enrolled in the "Movin' Out" Transitioning Protocol at a university-based adolescent medicine clinic providing care to adolescents/young adults with HIV infection. Almost half of the participants were able to successfully transition to adult care. Reasons for failure to transition included relocation, attrition, lost to follow-up, and transfer to another adult service. Failure to transition to adult care was not related to adherence issues, X(2) (1, N=38)=2.49, p=.288; substance use, X(2) (1, N=38)=1.71, p=.474; mental health issues, X(2) (1, N=38)=2.23, p=.322; or pregnancy/childrearing, X(2) (1, N=38)=0.00, p=.627). Despite the small sample size, the "Movin' Out" Transitioning Protocol appears to be useful in guiding the transition process of adolescents/young adults with HIV infection to adult care. More research is needed with a larger sample to fully evaluate the "Movin' Out" Transitioning Protocol. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. A new fit-for-purpose model testing framework: Decision Crash Tests

    NASA Astrophysics Data System (ADS)

    Tolson, Bryan; Craig, James

    2016-04-01

    Decision-makers in water resources are often burdened with selecting appropriate multi-million dollar strategies to mitigate the impacts of climate or land use change. Unfortunately, the suitability of existing hydrologic simulation models to accurately inform decision-making is in doubt because the testing procedures used to evaluate model utility (i.e., model validation) are insufficient. For example, many authors have identified that a good standard framework for model testing called the Klemes Crash Tests (KCTs), which are the classic model validation procedures from Klemeš (1986) that Andréassian et al. (2009) rename as KCTs, have yet to become common practice in hydrology. Furthermore, Andréassian et al. (2009) claim that the progression of hydrological science requires widespread use of KCT and the development of new crash tests. Existing simulation (not forecasting) model testing procedures such as KCTs look backwards (checking for consistency between simulations and past observations) rather than forwards (explicitly assessing if the model is likely to support future decisions). We propose a fundamentally different, forward-looking, decision-oriented hydrologic model testing framework based upon the concept of fit-for-purpose model testing that we call Decision Crash Tests or DCTs. Key DCT elements are i) the model purpose (i.e., decision the model is meant to support) must be identified so that model outputs can be mapped to management decisions ii) the framework evaluates not just the selected hydrologic model but the entire suite of model-building decisions associated with model discretization, calibration etc. The framework is constructed to directly and quantitatively evaluate model suitability. The DCT framework is applied to a model building case study on the Grand River in Ontario, Canada. A hypothetical binary decision scenario is analysed (upgrade or not upgrade the existing flood control structure) under two different sets of model building

  3. Effects of fecal sampling on preanalytical and analytical phases in quantitative fecal immunochemical tests for hemoglobin.

    PubMed

    Rapi, Stefano; Berardi, Margherita; Cellai, Filippo; Ciattini, Samuele; Chelazzi, Laura; Ognibene, Agostino; Rubeca, Tiziana

    2017-07-24

    Information on preanalytical variability is mandatory to bring laboratories up to ISO 15189 requirements. Fecal sampling is greatly affected by lack of harmonization in laboratory medicine. The aims of this study were to obtain information on the devices used for fecal sampling and to explore the effect of different amounts of feces on the results from the fecal immunochemical test for hemoglobin (FIT-Hb). Four commercial sample collection devices for quantitative FIT-Hb measurements were investigated. The volume of interest (VOI) of the probes was measured from diameter and geometry. Quantitative measurements of the mass of feces were carried out by gravimetry. The effects of an increased amount of feces on the analytical environment were investigated measuring the Hb values with a single analytical method. VOI was 8.22, 7.1 and 9.44 mm3 for probes that collected a target of 10 mg of feces, and 3.08 mm3 for one probe that targeted 2 mg of feces. The ratio between recovered and target amounts of devices ranged from 56% to 121%. Different changes in the measured Hb values were observed, in adding increasing amounts of feces in commercial buffers. The amounts of collected materials are related to the design of probes. Three out 4 manufacturers declare the same target amount using different sampling volumes and obtaining different amounts of collected materials. The introduction of a standard probes to reduce preanalytical variability could be an useful step for fecal test harmonization and to fulfill the ISO 15189 requirements.

  4. An Empirical Investigation of Methods for Assessing Item Fit for Mixed Format Tests

    ERIC Educational Resources Information Center

    Chon, Kyong Hee; Lee, Won-Chan; Ansley, Timothy N.

    2013-01-01

    Empirical information regarding performance of model-fit procedures has been a persistent need in measurement practice. Statistical procedures for evaluating item fit were applied to real test examples that consist of both dichotomously and polytomously scored items. The item fit statistics used in this study included the PARSCALE's G[squared],…

  5. Increasing students' physical activity during school physical education: rationale and protocol for the SELF-FIT cluster randomized controlled trial.

    PubMed

    Ha, Amy S; Lonsdale, Chris; Lubans, David R; Ng, Johan Y Y

    2017-07-11

    The Self-determined Exercise and Learning For FITness (SELF-FIT) is a multi-component school-based intervention based on tenets of self-determination theory. SELF-FIT aims to increase students' moderate-to-vigorous physical activity (MVPA) during physical education lessons, and enhance their autonomous motivation towards fitness activities. Using a cluster randomized controlled trial, we aim to examine the effects of the intervention on students' MVPA during school physical education. Secondary 2 students (approximately aged 14 years) from 26 classes in 26 different schools will be recruited. After baseline assessments, students will be randomized into either the experimental group or wait-list control group using a matched-pair randomization. Teachers allocated to the experimental group will attend two half-day workshops and deliver the SELF-FIT intervention for 8 weeks. The main intervention components include training teachers to teach in more need supportive ways, and conducting fitness exercises using a fitness dice with interchangeable faces. Other motivational components, such as playing music during classes, are also included. The primary outcome of the trial is students' MVPA during PE lessons. Secondary outcomes include students' leisure-time MVPA, perceived need support from teachers, need satisfaction, autonomous motivation towards physical education, intention to engage in physical activity, psychological well-being, and health-related fitness (cardiorespiratory and muscular fitness). Quantitative data will be analyzed using multilevel modeling approaches. Focus group interviews will also be conducted to assess students' perceptions of the intervention. The SELF-FIT intervention has been designed to improve students' health and well-being by using high-intensity activities in classes delivered by teachers who have been trained to be autonomy needs supportive. If successful, scalable interventions based on SELF-FIT could be applied in physical

  6. Exhaust-System Leak Test : Quantitative Procedure

    DOT National Transportation Integrated Search

    1974-01-01

    A quantitative, periodic motor vehicle safety-inspection test for determining the leakage rate of engine exhaust from an automotive exhaust system was investigated. Two technical approaches were evaluated, and the better one was selected for developm...

  7. Validity and Reliability of an on-Court Fitness Test for Assessing and Monitoring Aerobic Fitness in Squash.

    PubMed

    James, Carl Alexander; Vallejo, Florencio Tenllado; Kantebeen, Melvin; Farra, Saro

    2018-02-14

    Current on-court assessments of aerobic fitness in squash are not designed to yield a wealth of physiological data. Moreover, tests may require complex computer equipment or involve simulated racket strokes, which are difficult to standardize at high intensities. This study investigated the validity and reliability of a squash-specific fitness test which can yield both a standalone performance score, as well as pertinent physiological markers such as V[Combining Dot Above]O2max, the lactate turnpoint and oxygen cost, in a sport-specific environment. Eight national squash players completed three tests in a counter-balanced order; an incremental laboratory treadmill test (LAB) and two on-court fitness tests (ST) that involved repeated shuttle runs at increasing speeds. V[Combining Dot Above]O2max during ST was agreeable with LAB (Typical error [TE]=3.3 mL.kg.min, r=0.79). The mean bias between LAB and ST was 2.5 mL.kg.min. There were no differences in maximum heart rate, post exercise blood lactate concentration or end of test RPE between LAB and ST (p>0.05). The ST was highly reliable, with 74 (10) laps completed in ST1 and 75 (12) laps in ST2 (mean bias=1 lap, TE=3 laps, r=0.97). Physiological markers were also reliable, including V[Combining Dot Above]O2max, (TE=1.5 mL.kg.min, r=0.95), the lap number at 4 mMol (TE=4 laps, r=0.77) and average VO2 across the first 4 stages (TE=0.94 mL.kg.min, r=0.95). We observed good agreement between LAB and ST for assessing V[Combining Dot Above]O2max and between both on-court trials for assessing test performance and selected physiological markers. Consequently, we recommend this test for monitoring training adaptations and prescribing individualized training in elite squash players.

  8. Funtools: Fits Users Need Tools for Quick, Quantitative Analysis

    NASA Technical Reports Server (NTRS)

    Mandel, Eric; Brederkamp, Joe (Technical Monitor)

    2001-01-01

    The Funtools project arose out of conversations with astronomers about the decline in their software development efforts over the past decade. A stated reason for this decline is that it takes too much effort to master one of the existing FITS libraries simply in order to write a few analysis programs. This problem is exacerbated by the fact that astronomers typically develop new programs only occasionally, and the long interval between coding efforts often necessitates re-learning the FITS interfaces. We therefore set ourselves the goal of developing a minimal buy-in FITS library for researchers who are occasional (but serious) coders. In this case, "minimal buy-in" meant "easy to learn, easy to use, and easy to re-learn next month". Based on conversations with astronomers interested in writing code, we concluded that this goal could be achieved by emphasizing two essential capabilities. The first was the ability to write FITS programs without knowing much about FITS, i.e., without having to deal with the arcane rules for generating a properly formatted FITS file. The second was to support the use of already-familiar C/Unix facilities, especially C structs and Unix stdio. Taken together, these two capabilities would allow researchers to leverage their existing programming expertise while minimizing the need to learn new and complex coding rules.

  9. Quantitative and qualitative comparison of MR imaging of the temporomandibular joint at 1.5 and 3.0 T using an optimized high-resolution protocol

    PubMed Central

    Spinner, Georg; Wyss, Michael; Erni, Stefan; Ettlin, Dominik A; Nanz, Daniel; Ulbrich, Erika J; Gallo, Luigi M; Andreisek, Gustav

    2016-01-01

    Objectives: To quantitatively and qualitatively compare MRI of the temporomandibular joint (TMJ) using an optimized high-resolution protocol at 3.0 T and a clinical standard protocol at 1.5 T. Methods: A phantom and 12 asymptomatic volunteers were MR imaged using a 2-channel surface coil (standard TMJ coil) at 1.5 and 3.0 T (Philips Achieva and Philips Ingenia, respectively; Philips Healthcare, Best, Netherlands). Imaging protocol consisted of coronal and oblique sagittal proton density-weighted turbo spin echo sequences. For quantitative evaluation, a spherical phantom was imaged. Signal-to-noise ratio (SNR) maps were calculated on a voxelwise basis. For qualitative evaluation, all volunteers underwent MRI of the TMJ with the jaw in closed position. Two readers independently assessed visibility and delineation of anatomical structures of the TMJ and overall image quality on a 5-point Likert scale. Quantitative and qualitative measurements were compared between field strengths. Results: The quantitative analysis showed similar SNR for the high-resolution protocol at 3.0 T compared with the clinical protocol at 1.5 T. The qualitative analysis showed significantly better visibility and delineation of clinically relevant anatomical structures of the TMJ, including the TMJ disc and pterygoid muscle as well as better overall image quality at 3.0 T than at 1.5 T. Conclusions: The presented results indicate that expected gains in SNR at 3.0 T can be used to increase the spatial resolution when imaging the TMJ, which translates into increased visibility and delineation of anatomical structures of the TMJ. Therefore, imaging at 3.0 T should be preferred over 1.5 T for imaging the TMJ. PMID:26371077

  10. Quantitation of a slide test (Monotest) for infectious mononucleosis

    PubMed Central

    Carter, P. Kenneth; Schoen, Irwin; Miyahira, Teru

    1970-01-01

    A slide test for infectious mononucleosis using formalinized horse erythrocytes (Monotest2) was quantitated and compared with standard differential heterophile (Davidsohn) titres performed on the same specimens. The Monotest titre parallels the standard presumptive heterophile (antisheep cell) titre in the degree of elevation, with a ratio of Monotest to heterophile titre of approximately 1 to 56. The simplicity of the quantitative slide test recommends it as a routine test for infectious mononucleosis. PMID:5530641

  11. Generalized likelihood ratios for quantitative diagnostic test scores.

    PubMed

    Tandberg, D; Deely, J J; O'Malley, A J

    1997-11-01

    The reduction of quantitative diagnostic test scores to the dichotomous case is a wasteful and unnecessary simplification in the era of high-speed computing. Physicians could make better use of the information embedded in quantitative test results if modern generalized curve estimation techniques were applied to the likelihood functions of Bayes' theorem. Hand calculations could be completely avoided and computed graphical summaries provided instead. Graphs showing posttest probability of disease as a function of pretest probability with confidence intervals (POD plots) would enhance acceptance of these techniques if they were immediately available at the computer terminal when test results were retrieved. Such constructs would also provide immediate feedback to physicians when a valueless test had been ordered.

  12. Reliability and feasibility of physical fitness tests in female fibromyalgia patients.

    PubMed

    Carbonell-Baeza, A; Álvarez-Gallardo, I C; Segura-Jiménez, V; Castro-Piñero, J; Ruiz, J R; Delgado-Fernández, M; Aparicio, V A

    2015-02-01

    The aim of the present study was to determine the reliability and feasibility of physical fitness tests in female fibromyalgia patients. 100 female fibromyalgia patients (aged 50.6±8.6 years) performed the following tests twice (7 days interval test-retest): chair sit and reach, back scratch, handgrip strength, arm curl, chair stand, 8 feet up and go, and 6-min walk. Significant differences between test and retest were found in the arm curl (mean difference: 1.25±2.16 repetitions, Cohen d=0.251), chair stand (0.99±1.7 repetitions, Cohen d=0.254) and 8 feet up and go (-0.38±1.09 s, Cohen d=0.111) tests. Intraclass correlation coefficients (ICC) range from 0.92 in the arm curl test to 0.96 in the back scratch test. The feasibility of the tests (patients able to complete the test) ranged from 89% in the arm curl test to 100% in the handgrip strength test. Therefore, the reliability and feasibility of the physical fitness tests examined is acceptable for female fibromyalgia patients. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Reliability of Health-Related Physical Fitness Tests among Colombian Children and Adolescents: The FUPRECOL Study.

    PubMed

    Ramírez-Vélez, Robinson; Rodrigues-Bezerra, Diogo; Correa-Bautista, Jorge Enrique; Izquierdo, Mikel; Lobelo, Felipe

    2015-01-01

    Substantial evidence indicates that youth physical fitness levels are an important marker of lifestyle and cardio-metabolic health profiles and predict future risk of chronic diseases. The reliability physical fitness tests have not been explored in Latino-American youth population. This study's aim was to examine the reliability of health-related physical fitness tests that were used in the Colombian health promotion "Fuprecol study". Participants were 229 Colombian youth (boys n = 124 and girls n = 105) aged 9 to 17.9 years old. Five components of health-related physical fitness were measured: 1) morphological component: height, weight, body mass index (BMI), waist circumference, triceps skinfold, subscapular skinfold, and body fat (%) via impedance; 2) musculoskeletal component: handgrip and standing long jump test; 3) motor component: speed/agility test (4x10 m shuttle run); 4) flexibility component (hamstring and lumbar extensibility, sit-and-reach test); 5) cardiorespiratory component: 20-meter shuttle-run test (SRT) to estimate maximal oxygen consumption. The tests were performed two times, 1 week apart on the same day of the week, except for the SRT which was performed only once. Intra-observer technical errors of measurement (TEMs) and inter-rater (reliability) were assessed in the morphological component. Reliability for the Musculoskeletal, motor and cardiorespiratory fitness components was examined using Bland-Altman tests. For the morphological component, TEMs were small and reliability was greater than 95% of all cases. For the musculoskeletal, motor, flexibility and cardiorespiratory components, we found adequate reliability patterns in terms of systematic errors (bias) and random error (95% limits of agreement). When the fitness assessments were performed twice, the systematic error was nearly 0 for all tests, except for the sit and reach (mean difference: -1.03% [95% CI = -4.35% to -2.28%]. The results from this study indicate that the "Fuprecol

  14. Reliability of Health-Related Physical Fitness Tests among Colombian Children and Adolescents: The FUPRECOL Study

    PubMed Central

    Ramírez-Vélez, Robinson; Rodrigues-Bezerra, Diogo; Correa-Bautista, Jorge Enrique; Izquierdo, Mikel; Lobelo, Felipe

    2015-01-01

    Substantial evidence indicates that youth physical fitness levels are an important marker of lifestyle and cardio-metabolic health profiles and predict future risk of chronic diseases. The reliability physical fitness tests have not been explored in Latino-American youth population. This study’s aim was to examine the reliability of health-related physical fitness tests that were used in the Colombian health promotion “Fuprecol study”. Participants were 229 Colombian youth (boys n = 124 and girls n = 105) aged 9 to 17.9 years old. Five components of health-related physical fitness were measured: 1) morphological component: height, weight, body mass index (BMI), waist circumference, triceps skinfold, subscapular skinfold, and body fat (%) via impedance; 2) musculoskeletal component: handgrip and standing long jump test; 3) motor component: speed/agility test (4x10 m shuttle run); 4) flexibility component (hamstring and lumbar extensibility, sit-and-reach test); 5) cardiorespiratory component: 20-meter shuttle-run test (SRT) to estimate maximal oxygen consumption. The tests were performed two times, 1 week apart on the same day of the week, except for the SRT which was performed only once. Intra-observer technical errors of measurement (TEMs) and inter-rater (reliability) were assessed in the morphological component. Reliability for the Musculoskeletal, motor and cardiorespiratory fitness components was examined using Bland–Altman tests. For the morphological component, TEMs were small and reliability was greater than 95% of all cases. For the musculoskeletal, motor, flexibility and cardiorespiratory components, we found adequate reliability patterns in terms of systematic errors (bias) and random error (95% limits of agreement). When the fitness assessments were performed twice, the systematic error was nearly 0 for all tests, except for the sit and reach (mean difference: -1.03% [95% CI = -4.35% to -2.28%]. The results from this study indicate that the

  15. Correlations between Physical Fitness Tests and Performance of Military Tasks: A Systematic Review and Meta-Analyses

    DTIC Science & Technology

    2014-06-30

    U.S. Army Public Health Command Correlations between Physical Fitness Tests and Performance of Military Tasks: A Systematic Review and Meta...30 JUN 2014 2. REPORT TYPE Final 3. DATES COVERE D 4. TITLE AN D SUBTITLE Correlations between Physical Fitness Tests and Performance of... Physical Fitness Test (APFT) and ensure a future test is associated with Soldiers’ performance of common physical job requirements, the USAPHC applied

  16. Methacholine challenge testing: improved patient comfort with a 2-tiered protocol.

    PubMed

    Segel, Michael J; Rabinovich, Einat; Schwarz, Yehuda; Ben-Dov, Issahar

    2013-06-01

    The methacholine challenge test (MCT) is a test of bronchial hyperreactivity used as an aid in the diagnosis of asthma. MCT results are reported as the provocation concentration at which the forced expiratory volume in 1 second (FEV1) decreases 20% (PC20). The requirement for a 20% or greater decrease in FEV1 results in precipitous decreases in FEV1 in some patients. To improve MCT safety without compromising accuracy. We performed a retrospective analysis of 879 consecutive MCTs (derivation cohort). A novel protocol for MCT was developed and validated in a cohort of 564 MCTs performed in a second institution. In comparison with a PC20 cutoff of less than 8 mg/mL, a provocation concentration at which the FEV1 decreases 10% (PC10) cutoff of 1 mg/mL or less has a sensitivity of 86%, a specificity of 98%, a positive predictive value (PPV) of 97%, and a negative predictive value (NPV) of 91%. We propose a novel 2-tiered protocol for MCT. If the PC10 is 1 mg/mL or less, bronchial hyperreactivity is present; if the PC10 is greater than 1 mg/mL, the test is continued until the provocative concentration is 8 mg/mL or a 20% decrease in FEV1 is achieved. Compared with the standard protocol, the proposed protocol has a sensitivity, specificity, PPV, NPV, and overall accuracy of 100%, 98%, 97.6%, 100%, and 99%, respectively. The modified protocol would have enabled us to avoid 26 of 42 cases (62%) in which a 40% or greater decrease in FEV1 occurred and would save 0.65 dose for every MCT performed. The 2-tiered protocol performed well in the validation cohort; sensitivity, specificity, PPV, NPV, and overall accuracy were 100%, 98%, 87%, 100%, and 98%, respectively. The proposed 2-tiered protocol is accurate, saves time, and avoids precipitous decreases in FEV1. Copyright © 2013 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  17. Safety and Utility of Quantitative Sensory Testing among Adults with Sickle Cell Disease: Indicators of Neuropathic Pain?

    PubMed Central

    Ezenwa, Miriam O.; Molokie, Robert E.; Wang, Zaijie Jim; Yao, Yingwei; Suarez, Marie L.; Pullum, Cherese; Schlaeger, Judith M.; Fillingim, Roger B.; Wilkie, Diana J.

    2014-01-01

    Objectives Pain is the hallmark symptom of sickle cell disease (SCD), yet the types of pain that these patients experience, and the underlying mechanisms, have not been well characterized. The study purpose was to determine the safety and utility of a mechanical and thermal quantitative sensory testing (QST) protocol and the feasibility of utilizing neuropathic pain questionnaires among adults with SCD. Methods A convenience sample (N=25, 18 women, mean age 38.5 ± 12.5 [20–58 years]) completed self-report pain and quality-of-life tools. Subjects also underwent testing with the TSA-II NeuroSensory Analyzer and calibrated von Frey microfilaments. Results We found that the QST protocol was safe and did not stimulate a SCD pain crisis. There was evidence of central sensitization (n=15), peripheral sensitization (n=1), a mix of central and peripheral sensitization (n=8), or no sensitization (n=1). The neuropathic pain self-report tools were feasible with evidence of construct validity; 40% of the subjects reported S-LANSS scores that were indicative of neuropathic pain and had evidence of central, peripheral or mixed sensitization. Discussion The QST protocol can be safely conducted in adults with SCD and provides evidence of central or peripheral sensitization, which is consistent with a neuropathic component to SCD pain. These findings are novel, warrant a larger confirmatory study, and indicate the need for normative QST data from African American adults and older adults. PMID:25581383

  18. Protocols for Robust Herbicide Resistance Testing in Different Weed Species.

    PubMed

    Panozzo, Silvia; Scarabel, Laura; Collavo, Alberto; Sattin, Maurizio

    2015-07-02

    Robust protocols to test putative herbicide resistant weed populations at whole plant level are essential to confirm the resistance status. The presented protocols, based on whole-plant bioassays performed in a greenhouse, can be readily adapted to a wide range of weed species and herbicides through appropriate variants. Seed samples from plants that survived a field herbicide treatment are collected and stored dry at low temperature until used. Germination methods differ according to weed species and seed dormancy type. Seedlings at similar growth stage are transplanted and maintained in the greenhouse under appropriate conditions until plants have reached the right growth stage for herbicide treatment. Accuracy is required to prepare the herbicide solution to avoid unverifiable mistakes. Other critical steps such as the application volume and spray speed are also evaluated. The advantages of this protocol, compared to others based on whole plant bioassays using one herbicide dose, are related to the higher reliability and the possibility of inferring the resistance level. Quicker and less expensive in vivo or in vitro diagnostic screening tests have been proposed (Petri dish bioassays, spectrophotometric tests), but they provide only qualitative information and their widespread use is hindered by the laborious set-up that some species may require. For routine resistance testing, the proposed whole plant bioassay can be applied at only one herbicide dose, so reducing the costs.

  19. Hospital for Special Surgery Pediatric Functional Activity Brief Scale predicts physical fitness testing performance.

    PubMed

    Fabricant, Peter D; Robles, Alex; McLaren, Son H; Marx, Robert G; Widmann, Roger F; Green, Daniel W

    2014-05-01

    An eight-item activity scale was recently developed and validated for use as a prognostic tool in clinical research in children and adolescents. It is unclear, however, if this brief questionnaire is predictive of quantitative metrics of physical activity and fitness. The purposes of this study were to prospectively administer the Hospital for Special Surgery Pediatric Functional Activity Brief Scale to a large cohort of healthy adolescents to determine (1) if the activity scale exhibits any floor or ceiling effects; (2) if scores on the activity scale are correlated with standardized physical fitness metrics; and if so, (3) to determine the discrimination ability of the activity scale to differentiate between adolescents with healthy or unhealthy levels of aerobic capacity and calculate an appropriate cutoff value for its use as a screening tool. One hundred eighty-two adolescents (mean, 15.3 years old) prospectively completed the activity scale and four standardized metrics of physical fitness: pushups, sit-ups, shuttle run exercise (Progressive Aerobic Cardiovascular Endurance Run), and calculated VO2-max. Age, sex, and body mass index were also recorded. Pearson correlations, regression analyses, and receiver operating characteristic analyses were used to evaluate activity scale performance. The activity scale did not exhibit any floor or ceiling effects. Pushups (ρ = 0.28), sit-ups (ρ = 0.23), performance on the Progressive Aerobic Cardiovascular Endurance Run (ρ = 0.44), and VO2-max (ρ = 0.43) were all positively correlated with the activity scale score (Pearson correlations, all p < 0.001). Receiver operating characteristic analysis revealed that those with an activity score of ≤ 14 were at higher risk of having low levels of aerobic capacity. In the current study, activity score was free of floor and ceiling effects and predictive of all four physical fitness metrics. An activity score of ≤ 14 was associated with at-risk aerobic capacity previously

  20. Characterization of small-to-medium head-and-face dimensions for developing respirator fit test panels and evaluating fit of filtering facepiece respirators with different faceseal design

    PubMed Central

    Lin, Yi-Chun

    2017-01-01

    A respirator fit test panel (RFTP) with facial size distribution representative of intended users is essential to the evaluation of respirator fit for new models of respirators. In this study an anthropometric survey was conducted among youths representing respirator users in mid-Taiwan to characterize head-and-face dimensions key to RFTPs for application to small-to-medium facial features. The participants were fit-tested for three N95 masks of different facepiece design and the results compared to facial size distribution specified in the RFTPs of bivariate and principal component analysis design developed in this study to realize the influence of facial characteristics to respirator fit in relation to facepiece design. Nineteen dimensions were measured for 206 participants. In fit testing the qualitative fit test (QLFT) procedures prescribed by the U.S. Occupational Safety and Health Administration were adopted. As the results show, the bizygomatic breadth of the male and female participants were 90.1 and 90.8% of their counterparts reported for the U.S. youths (P < 0.001), respectively. Compared to the bivariate distribution, the PCA design better accommodated variation in facial contours among different respirator user groups or populations, with the RFTPs reported in this study and from literature consistently covering over 92% of the participants. Overall, the facial fit of filtering facepieces increased with increasing facial dimensions. The total percentages of the tests wherein the final maneuver being completed was “Moving head up-and-down”, “Talking” or “Bending over” in bivariate and PCA RFTPs were 13.3–61.9% and 22.9–52.8%, respectively. The respirators with a three-panel flat fold structured in the facepiece provided greater fit, particularly when the users moved heads. When the facial size distribution in a bivariate RFTP did not sufficiently represent petite facial size, the fit testing was inclined to overestimate the general fit

  1. Characterization of small-to-medium head-and-face dimensions for developing respirator fit test panels and evaluating fit of filtering facepiece respirators with different faceseal design.

    PubMed

    Lin, Yi-Chun; Chen, Chen-Peng

    2017-01-01

    A respirator fit test panel (RFTP) with facial size distribution representative of intended users is essential to the evaluation of respirator fit for new models of respirators. In this study an anthropometric survey was conducted among youths representing respirator users in mid-Taiwan to characterize head-and-face dimensions key to RFTPs for application to small-to-medium facial features. The participants were fit-tested for three N95 masks of different facepiece design and the results compared to facial size distribution specified in the RFTPs of bivariate and principal component analysis design developed in this study to realize the influence of facial characteristics to respirator fit in relation to facepiece design. Nineteen dimensions were measured for 206 participants. In fit testing the qualitative fit test (QLFT) procedures prescribed by the U.S. Occupational Safety and Health Administration were adopted. As the results show, the bizygomatic breadth of the male and female participants were 90.1 and 90.8% of their counterparts reported for the U.S. youths (P < 0.001), respectively. Compared to the bivariate distribution, the PCA design better accommodated variation in facial contours among different respirator user groups or populations, with the RFTPs reported in this study and from literature consistently covering over 92% of the participants. Overall, the facial fit of filtering facepieces increased with increasing facial dimensions. The total percentages of the tests wherein the final maneuver being completed was "Moving head up-and-down", "Talking" or "Bending over" in bivariate and PCA RFTPs were 13.3-61.9% and 22.9-52.8%, respectively. The respirators with a three-panel flat fold structured in the facepiece provided greater fit, particularly when the users moved heads. When the facial size distribution in a bivariate RFTP did not sufficiently represent petite facial size, the fit testing was inclined to overestimate the general fit, thus for small

  2. Epistasis and the Structure of Fitness Landscapes: Are Experimental Fitness Landscapes Compatible with Fisher’s Geometric Model?

    PubMed Central

    Blanquart, François; Bataillon, Thomas

    2016-01-01

    The fitness landscape defines the relationship between genotypes and fitness in a given environment and underlies fundamental quantities such as the distribution of selection coefficient and the magnitude and type of epistasis. A better understanding of variation in landscape structure across species and environments is thus necessary to understand and predict how populations will adapt. An increasing number of experiments investigate the properties of fitness landscapes by identifying mutations, constructing genotypes with combinations of these mutations, and measuring the fitness of these genotypes. Yet these empirical landscapes represent a very small sample of the vast space of all possible genotypes, and this sample is often biased by the protocol used to identify mutations. Here we develop a rigorous statistical framework based on Approximate Bayesian Computation to address these concerns and use this flexible framework to fit a broad class of phenotypic fitness models (including Fisher’s model) to 26 empirical landscapes representing nine diverse biological systems. Despite uncertainty owing to the small size of most published empirical landscapes, the inferred landscapes have similar structure in similar biological systems. Surprisingly, goodness-of-fit tests reveal that this class of phenotypic models, which has been successful so far in interpreting experimental data, is a plausible in only three of nine biological systems. More precisely, although Fisher’s model was able to explain several statistical properties of the landscapes—including the mean and SD of selection and epistasis coefficients—it was often unable to explain the full structure of fitness landscapes. PMID:27052568

  3. Vision-related fitness to drive mobility scooters: A practical driving test.

    PubMed

    Cordes, Christina; Heutink, Joost; Tucha, Oliver M; Brookhuis, Karel A; Brouwer, Wiebo H; Melis-Dankers, Bart J M

    2017-03-06

    To investigate practical fitness to drive mobility scooters, comparing visually impaired participants with healthy controls. Between-subjects design. Forty-six visually impaired (13 with very low visual acuity, 10 with low visual acuity, 11 with peripheral field defects, 12 with multiple visual impairment) and 35 normal-sighted controls. Participants completed a practical mobility scooter test-drive, which was recorded on video. Two independent occupational therapists specialized in orientation and mobility evaluated the videos systematically. Approximately 90% of the visually impaired participants passed the driving test. On average, participants with visual impairments performed worse than normal-sighted controls, but were judged sufficiently safe. In particular, difficulties were observed in participants with peripheral visual field defects and those with a combination of low visual acuity and visual field defects. People with visual impairment are, in practice, fit to drive mobility scooters; thus visual impairment on its own should not be viewed as a determinant of safety to drive mobility scooters. However, special attention should be paid to individuals with visual field defects with or without a combined low visual acuity. The use of an individual practical fitness-to-drive test is advised.

  4. A bottom-up approach in estimating the measurement uncertainty and other important considerations for quantitative analyses in drug testing for horses.

    PubMed

    Leung, Gary N W; Ho, Emmie N M; Kwok, W Him; Leung, David K K; Tang, Francis P W; Wan, Terence S M; Wong, April S Y; Wong, Colton H F; Wong, Jenny K Y; Yu, Nola H

    2007-09-07

    Quantitative determination, particularly for threshold substances in biological samples, is much more demanding than qualitative identification. A proper assessment of any quantitative determination is the measurement uncertainty (MU) associated with the determined value. The International Standard ISO/IEC 17025, "General requirements for the competence of testing and calibration laboratories", has more prescriptive requirements on the MU than its superseded document, ISO/IEC Guide 25. Under the 2005 or 1999 versions of the new standard, an estimation of the MU is mandatory for all quantitative determinations. To comply with the new requirement, a protocol was established in the authors' laboratory in 2001. The protocol has since evolved based on our practical experience, and a refined version was adopted in 2004. This paper describes our approach in establishing the MU, as well as some other important considerations, for the quantification of threshold substances in biological samples as applied in the area of doping control for horses. The testing of threshold substances can be viewed as a compliance test (or testing to a specified limit). As such, it should only be necessary to establish the MU at the threshold level. The steps in a "Bottom-Up" approach adopted by us are similar to those described in the EURACHEM/CITAC guide, "Quantifying Uncertainty in Analytical Measurement". They involve first specifying the measurand, including the relationship between the measurand and the input quantities upon which it depends. This is followed by identifying all applicable uncertainty contributions using a "cause and effect" diagram. The magnitude of each uncertainty component is then calculated and converted to a standard uncertainty. A recovery study is also conducted to determine if the method bias is significant and whether a recovery (or correction) factor needs to be applied. All standard uncertainties with values greater than 30% of the largest one are then used to

  5. Auditory fitness for duty: a review.

    PubMed

    Tufts, Jennifer B; Vasil, Kristin A; Briggs, Sarah

    2009-10-01

    Auditory fitness for duty (AFFD) refers to the possession of hearing abilities sufficient for safe and effective job performance. In jobs such as law enforcement and piloting, where the ability to hear is critical to job performance and safety, hearing loss can decrease performance, even to the point of being hazardous to self and others. Tests of AFFD should provide an employer with a valid assessment of an employee's ability to perform the job safely, without discriminating against the employee purely on the basis of hearing loss. The purpose of this review is to provide a basic description of the functional hearing abilities required in hearing-critical occupations, and a summary of current practices in AFFD evaluation. In addition, we suggest directions for research and standardization to ensure best practices in the evaluation of AFFD in the future. We conducted a systematic review of the English-language peer-reviewed literature in AFFD. "Popular" search engines were consulted for governmental regulations and trade journal articles. We also contacted professionals with expertise in AFFD regarding research projects, unpublished material, and current standards. The literature review provided information regarding the functional hearing abilities required to perform hearing-critical tasks, the development of and characteristics of AFFD protocols, and the current implementation of AFFD protocols. This review paper provides evidence of the need to institute job-specific AFFD protocols, move beyond the pure-tone audiogram, and establish the validity of test protocols. These needs are arguably greater now than in times past.

  6. Propagating mass accretion rate fluctuations in black hole X-ray binaries: quantitative tests

    NASA Astrophysics Data System (ADS)

    Rapisarda, S.; Ingram, A.; van der Klis, M.

    2017-10-01

    Over the past 20 years, a consistent phenomenology has been established to describe the variability properties of Black Hole X-ray Binaries (BHBs). However, the physics behind the observational data is still poorly understood. The recently proposed model PROPFLUC assumes a truncated disc/hot inner flow geometry, with mass accretion rate fluctuations propagating through a precessing inner flow. These two processes give rise respectively to broad band variability and QPO. Because of propagation, the emission from different regions of the disc/hot flow geometry is correlated. In our study we applied the model PROPFLUC on different BHBs (including XTE J1550-564 and Cygnus X-1) in different spectral states, fitting jointly the power spectra in two energy bands and the cross-spectrum between these two bands. This represents the first study to utilize quantitive fitting of a physical model simultaneously to observed power and cross-spectra. For the case of XTE J1550-564, which displays a strong QPO, we found quantitative and qualitative discrepancies between model predictions and data, whereas we find a good fit for the Cygnus X-1 data, which does not display a QPO. We conclude that the discrepancies are generic to the propagating fluctuations paradigm, and may be related to the mechanism originating the QPO.

  7. Effect of training with and without a load on military fitness tests and marksmanship.

    PubMed

    Swain, David P; Ringleb, Stacie I; Naik, Dayanand N; Butowicz, Courtney M

    2011-07-01

    The purpose of this study was to determine whether military-style training performed while carrying a weighted vest and backpack (Load condition) resulted in superior training adaptations (specifically, changes in military fitness and marksmanship) than did more conventional training (No-Load condition). A total of 33 college-aged men and women (16 Load, 17 No-Load) completed all testing and 9 weeks of training (1 h·d, 4 d·wk). No-Load training consisted of military calisthenics, sprints, agility drills, and running. Load training was similar except that running was replaced with stair climbing, and Load increased across the 9 weeks to 20 kg for women and 30 kg for men. Pretraining and posttraining, all subjects performed an uphill treadmill test with full load to determine peak oxygen consumption (VO(2)peak), the marine physical fitness test (PFT) and combat fitness test (CFT) without load, other fitness tests, and an indoor marksmanship test using a laser-fitted carbine. The marksmanship test was performed with full load and done before and immediately after a 200-m shuttle run performed in 60 seconds. Both groups significantly improved their VO(2)peak, PFT, and CFT scores by similar amounts. Pretraining, shooting score decreased significantly after the 200-m run and then rapidly recovered, with no difference between groups. A similar, but nonsignificant, pattern in shooting scores was seen in both groups posttraining. In conclusion, loaded training did not produce measurable advantages compared with unloaded training in this population. A strenuous anaerobic challenge caused a temporary reduction in marksmanship.

  8. Physical Fitness Test Battery for Mentally Retarded Children (Trainable and Educable).

    ERIC Educational Resources Information Center

    Fait, Hollis F.

    A physical fitness test battery for educable and trainable mentally handicapped children is presented. Instructions are given for administering the test; descriptions are given of the seven test items, including the 25 yard run, bent arm hang, leg lift, static balance, thrust, and 300 yard run-walk. Rationale for the items and factors in…

  9. A quantitative model for designing keyboard layout.

    PubMed

    Shieh, K K; Lin, C C

    1999-02-01

    This study analyzed the quantitative relationship between keytapping times and ergonomic principles in typewriting skills. Keytapping times and key-operating characteristics of a female subject typing on the Qwerty and Dvorak keyboards for six weeks each were collected and analyzed. The results showed that characteristics of the typed material and the movements of hands and fingers were significantly related to keytapping times. The most significant factors affecting keytapping times were association frequency between letters, consecutive use of the same hand or finger, and the finger used. A regression equation for relating keytapping times to ergonomic principles was fitted to the data. Finally, a protocol for design of computerized keyboard layout based on the regression equation was proposed.

  10. Evaluation of Aspergillus PCR Protocols for Testing Serum Specimens▿†

    PubMed Central

    White, P. Lewis; Mengoli, Carlo; Bretagne, Stéphane; Cuenca-Estrella, Manuel; Finnstrom, Niklas; Klingspor, Lena; Melchers, Willem J. G.; McCulloch, Elaine; Barnes, Rosemary A.; Donnelly, J. Peter; Loeffler, Juergen

    2011-01-01

    A panel of human serum samples spiked with various amounts of Aspergillus fumigatus genomic DNA was distributed to 23 centers within the European Aspergillus PCR Initiative to determine analytical performance of PCR. Information regarding specific methodological components and PCR performance was requested. The information provided was made anonymous, and meta-regression analysis was performed to determine any procedural factors that significantly altered PCR performance. Ninety-seven percent of protocols were able to detect a threshold of 10 genomes/ml on at least one occasion, with 83% of protocols reproducibly detecting this concentration. Sensitivity and specificity were 86.1% and 93.6%, respectively. Positive associations between sensitivity and the use of larger sample volumes, an internal control PCR, and PCR targeting the internal transcribed spacer (ITS) region were shown. Negative associations between sensitivity and the use of larger elution volumes (≥100 μl) and PCR targeting the mitochondrial genes were demonstrated. Most Aspergillus PCR protocols used to test serum generate satisfactory analytical performance. Testing serum requires less standardization, and the specific recommendations shown in this article will only improve performance. PMID:21940479

  11. Titrating Oxygen Requirements During Exercise: Evaluation of a Standardized Single Walk Test Protocol.

    PubMed

    Giovacchini, Coral X; Mathews, Anne M; Lawlor, Brian R; MacIntyre, Neil R

    2018-04-01

    Oxygen supplementation for exercise-induced hypoxemia is a common clinical practice that improves exercise tolerance. However, we know of no standardized exercise oxygen titration protocol using a single walk test. We report our experience with a protocol developed in our laboratory. Our protocol is based on the 6-min walk test (6MWT). Pulse oximetry readings (oxygen saturation [Spo 2 ]) are monitored, and supplemental oxygen is added in 2 L/min increments to keep Spo 2 > 88%. This continues for at least 6 min of walking with the Spo 2 remaining > 88% for at least 3 min. The records of consecutive patients over 4 months undergoing this procedure were reviewed for test performance, oxygen titration results, and adverse events. Two hundred twenty-two patients were tested; only two prematurely terminated the protocol because of intractable dyspnea. One hundred fifty-six patients (38%) required oxygen supplementation, with the first titration most commonly occurring between 1 and 2 min of walking. Nine of the patients had the first titration after 5 min of walking. The average test duration was 7 min (maximum, 15 min). The average number of titrations was 2.2 (maximum six). Sixteen patients could not maintain Spo 2 > 88% for 3 min despite administration of 15 L/min of supplemental oxygen (maximal dose). Our protocol was easily performed as a modification of a standard 6MWT with no serious adverse events. Because it is based on a widely accepted measurement of functional capabilities, and because it determined a stable final oxygen dose for ≥ 3 min of walking in most patients, we believe this protocol can be easily adapted for clinical use. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  12. Measurement properties of maximal cardiopulmonary exercise tests protocols in persons after stroke: A systematic review.

    PubMed

    Wittink, Harriet; Verschuren, Olaf; Terwee, Caroline; de Groot, Janke; Kwakkel, Gert; van de Port, Ingrid

    2017-11-21

    To systematically review and critically appraise the literature on measurement properties of cardiopulmonary exercise test protocols for measuring aerobic capacity, VO2max, in persons after stroke. PubMed, Embase and Cinahl were searched from inception up to 15 June 2016. A total of 9 studies were identified reporting on 9 different cardiopulmonary exercise test protocols. VO2max measured with cardiopulmonary exercise test and open spirometry was the construct of interest. The target population was adult persons after stroke. We included all studies that evaluated reliability, measurement error, criterion validity, content validity, hypothesis testing and/or responsiveness of cardiopulmonary exercise test protocols. Two researchers independently screened the literature, assessed methodological quality using the COnsensus-based Standards for the selection of health Measurement INstruments checklist and extracted data on measurement properties of cardiopulmonary exercise test protocols. Most studies reported on only one measurement property. Best-evidence synthesis was derived taking into account the methodological quality of the studies, the results and the consistency of the results. No judgement could be made on which protocol is "best" for measuring VO2max in persons after stroke due to lack of high-quality studies on the measurement properties of the cardiopulmonary exercise test.

  13. Framework and indicator testing protocol for developing and piloting quality indicators for the UK quality and outcomes framework.

    PubMed

    Campbell, Stephen M; Kontopantelis, Evangelos; Hannon, Kerin; Burke, Martyn; Barber, Annette; Lester, Helen E

    2011-08-10

    Quality measures should be subjected to a testing protocol before being used in practice using key attributes such as acceptability, feasibility and reliability, as well as identifying issues derived from actual implementation and unintended consequences. We describe the methodologies and results of an indicator testing protocol (ITP) using data from proposed quality indicators for the United Kingdom Quality and Outcomes Framework (QOF). The indicator testing protocol involved a multi-step and methodological process: 1) The RAND/UCLA Appropriateness Method, to test clarity and necessity, 2) data extraction from patients' medical records, to test technical feasibility and reliability, 3) diaries, to test workload, 4) cost-effectiveness modelling, and 5) semi-structured interviews, to test acceptability, implementation issues and unintended consequences. Testing was conducted in a sample of representative family practices in England. These methods were combined into an overall recommendation for each tested indicator. Using an indicator testing protocol as part of piloting was seen as a valuable way of testing potential indicators in 'real world' settings. Pilot 1 (October 2009-March 2010) involved thirteen indicators across six clinical domains and twelve indicators passed the indicator testing protocol. However, the indicator testing protocol identified a number of implementation issues and unintended consequences that can be rectified or removed prior to national roll out. A palliative care indicator is used as an exemplar of the value of piloting using a multiple attribute indicator testing protocol - while technically feasible and reliable, it was unacceptable to practice staff and raised concerns about potentially causing actual patient harm. This indicator testing protocol is one example of a protocol that may be useful in assessing potential quality indicators when adapted to specific country health care settings and may be of use to policy-makers and

  14. Quantitative analysis of the pendulum test: application to multiple sclerosis patients treated with botulinum toxin.

    PubMed

    Bianchi, L; Monaldi, F; Paolucci, S; Iani, C; Lacquaniti, F

    1999-01-01

    The aim of this study was to develop quantitative analytical methods in the application of the pendulum test to both normal and spastic subjects. The lower leg was released by a torque motor from different starting positions. The resulting changes in the knee angle were fitted by means of a time-varying model. Stiffness and viscosity coefficients were derived for each half-cycle oscillation in both flexion and extension, and for all knee starting positions. This method was applied to the assessment of the effects of Botulinum toxin A (BTX) in progressive multiple sclerosis patients in a follow-up study. About half of the patients showed a significant decrement in stiffness and viscosity coefficients.

  15. Validity of a Newly-Designed Rectilinear Stepping Ergometer Submaximal Exercise Test to Assess Cardiorespiratory Fitness.

    PubMed

    Zhang, Rubin; Zhan, Likui; Sun, Shaoming; Peng, Wei; Sun, Yining

    2017-09-01

    The maximum oxygen uptake (V̇O 2 max), determined from graded maximal or submaximal exercise tests, is used to classify the cardiorespiratory fitness level of individuals. The purpose of this study was to examine the validity and reliability of the YMCA submaximal exercise test protocol performed on a newly-designed rectilinear stepping ergometer (RSE) that used up and down reciprocating vertical motion in place of conventional circular motion and giving precise measurement of workload, to determine V̇O 2 max in young healthy male adults. Thirty-two young healthy male adults (32 males; age range: 20-35 years; height: 1.75 ± 0.05 m; weight: 67.5 ± 8.6 kg) firstly participated in a maximal-effort graded exercise test using a cycle ergometer (CE) to directly obtain measured V̇O 2 max. Subjects then completed the progressive multistage test on the RSE beginning at 50W and including additional stages of 70, 90, 110, 130, and 150W, and the RSE YMCA submaximal test consisting of a workload increase every 3 minutes until the termination criterion was reached. A metabolic equation was derived from the RSE multistage exercise test to predict oxygen consumption (V̇O 2 ) from power output (W) during the submaximal exercise test (V̇O 2 (mL·min -1 )=12.4 ×W(watts)+3.5 mL·kg -1 ·min -1 ×M+160mL·min -1 , R 2 = 0.91, standard error of the estimate (SEE) = 134.8mL·min -1 ). A high correlation was observed between the RSE YMCA estimated V̇O 2 max and the CE measured V̇O 2 max (r=0.87). The mean difference between estimated and measured V̇O 2 max was 2.5 mL·kg -1 ·min -1 , with an SEE of 3.55 mL·kg -1 ·min -1 . The data suggest that the RSE YMCA submaximal exercise test is valid for predicting V̇O 2 max in young healthy male adults. The findings show that the rectilinear stepping exercise is an effective submaximal exercise for predicting V̇O 2 max. The newly-designed RSE may be potentially further developed as an alternative ergometer for assessing

  16. Smartphone apps to improve fitness and increase physical activity among young people: protocol of the Apps for IMproving FITness (AIMFIT) randomized controlled trial.

    PubMed

    Direito, Artur; Jiang, Yannan; Whittaker, Robyn; Maddison, Ralph

    2015-07-11

    Physical activity is a modifiable behavior related to many preventable non-communicable diseases. There is an age-related decline in physical activity levels in young people, which tracks into adulthood. Common interactive technologies such as smartphones, particularly employing immersive features, may enhance the appeal and delivery of interventions to increase levels of physical activity in young people. The primary aim of the Apps for IMproving FITness (AIMFIT) trial is to evaluate the effectiveness of two popular "off-the-shelf" smartphone apps for improving cardiorespiratory fitness in young people. A three-arm, parallel, randomized controlled trial will be conducted in Auckland, New Zealand. Fifty-one eligible young people aged 14-17 years will be randomized to one of three conditions: 1) use of an immersive smartphone app, 2) use of a non-immersive app, or 3) usual behavior (control). Both smartphone apps consist of an eight-week training program designed to improve fitness and ability to run 5 km, however, the immersive app features a game-themed design and adds a narrative. Data are collected at baseline and 8 weeks. The primary outcome is cardiorespiratory fitness, assessed as time to complete the one mile run/walk test at 8 weeks. Secondary outcomes are physical activity levels, self-efficacy, enjoyment, psychological need satisfaction, and acceptability and usability of the apps. Analysis using intention to treat principles will be performed using regression models. Despite the proliferation of commercially available smartphone applications, there is a dearth of empirical evidence to support their effectiveness on the targeted health behavior. This pragmatic study will determine the effectiveness of two popular "off-the-shelf" apps as a stand-alone instrument for improving fitness and physical activity among young people. Adherence to app use will not be closely controlled; however, random allocation of participants, a heterogeneous group, and data

  17. A general dual-bolus approach for quantitative DCE-MRI.

    PubMed

    Kershaw, Lucy E; Cheng, Hai-Ling Margaret

    2011-02-01

    To present a dual-bolus technique for quantitative dynamic contrast-enhanced MRI (DCE-MRI) and show that it can give an arterial input function (AIF) measurement equivalent to that from a single-bolus protocol. Five rabbits were imaged using a dual-bolus technique applicable for high-resolution DCE-MRI, incorporating a time resolved imaging of contrast kinetics (TRICKS) sequence for rapid temporal sampling. AIFs were measured from both the low-dose prebolus and the high-dose main bolus in the abdominal aorta. In one animal, TRICKS and fast spoiled gradient echo (FSPGR) acquisitions were compared. The scaled prebolus AIF was shown to match the main bolus AIF, with 95% confidence intervals overlapping for fits of gamma-variate functions to the first pass and linear fits to the washout phase, with the exception of one case. The AIFs measured using TRICKS and FSPGR were shown to be equivalent in one animal. The proposed technique can capture even the rapid circulation kinetics in the rabbit aorta, and the scaled prebolus AIF is equivalent to the AIF from a high-dose injection. This allows separate measurements of the AIF and tissue uptake curves, meaning that each curve can then be acquired using a protocol tailored to its specific requirements. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. Physical Fitness and Hypertension in a Population at Risk for Cardiovascular Disease: The Henry Ford ExercIse Testing (FIT) Project

    PubMed Central

    Juraschek, Stephen P.; Blaha, Michael J.; Whelton, Seamus P.; Blumenthal, Roger; Jones, Steven R.; Keteyian, Steven J.; Schairer, John; Brawner, Clinton A.; Al‐Mallah, Mouaz H.

    2014-01-01

    Background Increased physical fitness is protective against cardiovascular disease. We hypothesized that increased fitness would be inversely associated with hypertension. Methods and Results We examined the association of fitness with prevalent and incident hypertension in 57 284 participants from The Henry Ford ExercIse Testing (FIT) Project (1991–2009). Fitness was measured during a clinician‐referred treadmill stress test. Incident hypertension was defined as a new diagnosis of hypertension on 3 separate consecutive encounters derived from electronic medical records or administrative claims files. Analyses were performed with logistic regression or Cox proportional hazards models and were adjusted for hypertension risk factors. The mean age overall was 53 years, with 49% women and 29% black. Mean peak metabolic equivalents (METs) achieved was 9.2 (SD, 3.0). Fitness was inversely associated with prevalent hypertension even after adjustment (≥12 METs versus <6 METs; OR: 0.73; 95% CI: 0.67, 0.80). During a median follow‐up period of 4.4 years (interquartile range: 2.2 to 7.7 years), there were 8053 new cases of hypertension (36.4% of 22 109 participants without baseline hypertension). The unadjusted 5‐year cumulative incidences across categories of METs (<6, 6 to 9, 10 to 11, and ≥12) were 49%, 41%, 30%, and 21%. After adjustment, participants achieving ≥12 METs had a 20% lower risk of incident hypertension compared to participants achieving <6 METs (HR: 0.80; 95% CI: 0.72, 0.89). This relationship was preserved across strata of age, sex, race, obesity, resting blood pressure, and diabetes. Conclusions Higher fitness is associated with a lower probability of prevalent and incident hypertension independent of baseline risk factors. PMID:25520327

  19. Fitness testing as a discriminative tool for the diagnosis and monitoring of fibromyalgia.

    PubMed

    Aparicio, V A; Carbonell-Baeza, A; Ruiz, J R; Aranda, P; Tercedor, P; Delgado-Fernández, M; Ortega, F B

    2013-08-01

    We aimed to determine the ability of a set of physical fitness tests to discriminate between presence/absence of fibromyalgia (FM) and moderate/severe FM. The sample comprised 94 female FM patients (52 ± 8 years) and 66 healthy women (54 ± 6 years). We assessed physical fitness by means of the 30-s chair stand, handgrip strength, chair sit and reach, back scratch, blind flamingo, 8-feet up and go, and 6-min walking tests. Patients were classified as having moderate FM if the score in the Fibromyalgia Impact Questionnaire (FIQ) was <70 and as having severe FM if the FIQ was ≥70. FM patients and patients with severe FM performed worse in most of the fitness tests studied (P < 0.001). Except the back scratch test, all the tests were able to discriminate between presence and absence of FM [area under the curve (AUC) = 0.66 to 0.92; P ≤ 0.001], and four tests also discriminated FM severity (AUC = 0.62 to 0.66; P ≤ 0.05). The 30-s chair stand test showed the highest ability to discriminate FM presence and severity (AUC = 0.92, P < 0.001; and AUC = 0.66, P = 0.008, respectively), being the corresponding discriminating cutoffs 9 and 6 repetitions, respectively. Physical fitness in general, and particularly the 30-s chair stand test, is able to discriminate between women with FM from those without FM, as well as between those with moderate FM from their peers with severe FM. © 2011 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Person Fit Based on Statistical Process Control in an Adaptive Testing Environment. Research Report 98-13.

    ERIC Educational Resources Information Center

    van Krimpen-Stoop, Edith M. L. A.; Meijer, Rob R.

    Person-fit research in the context of paper-and-pencil tests is reviewed, and some specific problems regarding person fit in the context of computerized adaptive testing (CAT) are discussed. Some new methods are proposed to investigate person fit in a CAT environment. These statistics are based on Statistical Process Control (SPC) theory. A…

  1. Development of 1-Mile Walk Tests to Estimate Aerobic Fitness in Children

    ERIC Educational Resources Information Center

    Sung, Hoyong; Collier, David N.; DuBose, Katrina D.; Kemble, C. David; Mahar, Matthew T.

    2018-01-01

    To examine the reliability and validity of 1-mile walk tests for estimation of aerobic fitness (VO[subscript 2max]) in 10- to 13-year-old children and to cross-validate previously published equations. Participants (n = 61) walked 1-mile on two different days. Self-reported physical activity, demographic variables, and aerobic fitness were used in…

  2. K-S Test for Goodness of Fit and Waiting Times for Fatal Plane Accidents

    ERIC Educational Resources Information Center

    Gwanyama, Philip Wagala

    2005-01-01

    The Kolmogorov?Smirnov (K-S) test for goodness of fit was developed by Kolmogorov in 1933 [1] and Smirnov in 1939 [2]. Its procedures are suitable for testing the goodness of fit of a data set for most probability distributions regardless of sample size [3-5]. These procedures, modified for the exponential distribution by Lilliefors [5] and…

  3. Must School Districts Provide Test Protocols to Parents?

    ERIC Educational Resources Information Center

    Rosenfeld, S. James

    2010-01-01

    Despite being well-settled as a matter of law, the issue of whether test protocols must be disclosed to parents continues to be a source of dispute between schools, school psychologists, and parents. To be sure, one of the reasons for this vampire-like existence is the imprecision of the questioners and questions. Moreover, professional guidance…

  4. Test-retest reliability of quantitative sensory testing for mechanical somatosensory and pain modulation assessment of masticatory structures.

    PubMed

    Costa, Y M; Morita-Neto, O; de Araújo-Júnior, E N S; Sampaio, F A; Conti, P C R; Bonjardim, L R

    2017-03-01

    Assessing the reliability of medical measurements is a crucial step towards the elaboration of an applicable clinical instrument. There are few studies that evaluate the reliability of somatosensory assessment and pain modulation of masticatory structures. This study estimated the test-retest reliability, that is over time, of the mechanical somatosensory assessment of anterior temporalis, masseter and temporomandibular joint (TMJ) and the conditioned pain modulation (CPM) using the anterior temporalis as the test site. Twenty healthy women were evaluated in two sessions (1 week apart) by the same examiner. Mechanical detection threshold (MDT), mechanical pain threshold (MPT), wind-up ratio (WUR) and pressure pain threshold (PPT) were assessed on the skin overlying the anterior temporalis, masseter and TMJ of the dominant side. CPM was tested by comparing PPT before and during the hand immersion in a hot water bath. anova and intra-class correlation coefficients (ICCs) were applied to the data (α = 5%). The overall ICCs showed acceptable values for the test-retest reliability of mechanical somatosensory assessment of masticatory structures. The ICC values of 75% of all quantitative sensory measurements were considered fair to excellent (fair = 8·4%, good = 33·3% and excellent = 33·3%). However, the CPM paradigm presented poor reliability (ICC = 0·25). The mechanical somatosensory assessment of the masticatory structures, but not the proposed CPM protocol, can be considered sufficiently reliable over time to evaluate the trigeminal sensory function. © 2016 John Wiley & Sons Ltd.

  5. Development and design of a late-model fitness test instrument based on LabView

    NASA Astrophysics Data System (ADS)

    Xie, Ying; Wu, Feiqing

    2010-12-01

    Undergraduates are pioneers of China's modernization program and undertake the historic mission of rejuvenating our nation in the 21st century, whose physical fitness is vital. A smart fitness test system can well help them understand their fitness and health conditions, thus they can choose more suitable approaches and make practical plans for exercising according to their own situation. following the future trends, a Late-model fitness test Instrument based on LabView has been designed to remedy defects of today's instruments. The system hardware consists of fives types of sensors with their peripheral circuits, an acquisition card of NI USB-6251 and a computer, while the system software, on the basis of LabView, includes modules of user register, data acquisition, data process and display, and data storage. The system, featured by modularization and an open structure, is able to be revised according to actual needs. Tests results have verified the system's stability and reliability.

  6. Moving Real Exergaming Engines on the Web: The webFitForAll Case Study in an Active and Healthy Ageing Living Lab Environment.

    PubMed

    Konstantinidis, Evdokimos I; Bamparopoulos, Giorgos; Bamidis, Panagiotis D

    2017-05-01

    Exergames have been the subject of research and technology innovations for a number of years. Different devices and technologies have been utilized to train the body and the mind of senior people or different patient groups. In the past, we presented FitForAll, the protocol efficacy of which was proven through widely taken (controlled) pilots with more than 116 seniors for a period of two months. The current piece of work expands this and presents the first truly web exergaming platform, which is solely based on HTML5 and JavaScript without any browser plugin requirements. The adopted architecture (controller application communication framework) combines a unified solution for input devices such as MS Kinect and Wii Balance Βoard which may seamlessly be exploited through standard physical exercise protocols (American College of Sports Medicine guidelines) and accommodate high detail logging; this allows for proper pilot testing and usability evaluations in ecologically valid Living Lab environments. The latter type of setups is also used herein for evaluating the web application with more than a dozen of real elderly users following quantitative approaches.

  7. Health Worker Compliance with a 'Test And Treat' Malaria Case Management Protocol in Papua New Guinea.

    PubMed

    Pulford, Justin; Smith, Iso; Mueller, Ivo; Siba, Peter M; Hetzel, Manuel W

    2016-01-01

    The Papua New Guinea (PNG) Department of Health introduced a 'test and treat' malaria case management protocol in 2011. This study assesses health worker compliance with the test and treat protocol on a wide range of measures, examines self-reported barriers to health worker compliance as well as health worker attitudes towards the test and treat protocol. Data were collected by cross-sectional survey conducted in randomly selected primary health care facilities in 2012 and repeated in 2014. The combined survey data included passive observation of current or recently febrile patients (N = 771) and interviewer administered questionnaires completed with health workers (N = 265). Across the two surveys, 77.6% of patients were tested for malaria infection by rapid diagnostic test (RDT) or microscopy, 65.6% of confirmed malaria cases were prescribed the correct antimalarials and 15.3% of febrile patients who tested negative for malaria infection were incorrectly prescribed an antimalarial. Overall compliance with a strictly defined test and treat protocol was 62.8%. A reluctance to test current/recently febrile patients for malaria infection by RDT or microscopy in the absence of acute malaria symptoms, reserving recommended antimalarials for confirmed malaria cases only and choosing to clinically diagnose a malaria infection, despite a negative RDT result were the most frequently reported barriers to protocol compliance. Attitudinal support for the test and treat protocol, as assessed by a nine-item measure, improved across time. In conclusion, health worker compliance with the full test and treat malaria protocol requires improvement in PNG and additional health worker support will likely be required to achieve this. The broader evidence base would suggest any such support should be delivered over a longer period of time, be multi-dimensional and multi-modal.

  8. Fit-for-purpose wastewater treatment: Testing to implementation of decision support tool (II).

    PubMed

    Chhipi-Shrestha, Gyan; Hewage, Kasun; Sadiq, Rehan

    2017-12-31

    This paper is the second in a series of two papers. In Paper I, a decision support tool (DST), FitWater, was developed for evaluating the potential of wastewater treatment (WWT) trains for various water reuse applications. In the present paper, the proposed DST has been tested and implemented. FitWater has been tested with several existing WWT plants in Canada and the USA, demonstrating FitWater's effectiveness in estimating life cycle cost (LCC), health risk, and energy use. FitWater has also been implemented in a newly planned neighbourhood in the Okanagan Valley (BC, Canada) by developing 12 alternative WWT trains for water reuse in lawn and public parks irrigation. The results show that FitWater can effectively rank WWT train alternatives based on LCC, health risk, amount of reclaimed water, energy use, and carbon emissions. Moreover, functions have been developed for the variation of unit annualized LCC and energy intensity per unit log removal of microorganisms in different treatment technologies with varying plant capacities. The functions have power relations, showing the economies of scale. FitWater can be applied to identify a cost-effective, risk-acceptable, and energy efficient wastewater treatment train with a plant capacity of 500m 3 /day or more. Furthermore, FitWater can be used to assess potential economic impacts of developing microbiologically stringent effluent standards. The capability of FitWater can be enhanced by including physio-chemical quality of wastewater, additional treatment technologies, and carbon emissions from wastewater decomposition processes. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Designing typefaces for maps. A protocol of tests.

    NASA Astrophysics Data System (ADS)

    Biniek, Sébastien; Touya, Guillaume; Rouffineau, Gilles; Huot-Marchand, Thomas

    2018-05-01

    The text management in map design is a topic generally linked to placement and composition issues. Whereas the type design issue is rarely addressed or at least only partially. Moreover the typefaces especially designed for maps are rare. This paper presents a protocol of tests to evaluate characters for digital topographic maps and fonts that were designed for the screen through the use of geographical information systems using this protocol. It was launched by the Atelier National de Recherche Typographique Research (ANRT, located in Nancy, France) and took place over his `post-master' course in 2013. The purpose is to isolate different issues inherent to text in a topographic map: map background, nonlinear text placement and toponymic hierarchies. Further research is necessary to improve this kind of approach.

  10. Dynamic Warm-Up Protocols, With and Without a Weighted Vest, and Fitness Performance in High School Female Athletes

    PubMed Central

    Faigenbaum, Avery D; McFarland, James E; Schwerdtman, Jeff A; Ratamess, Nicholas A; Kang, Jie; Hoffman, Jay R

    2006-01-01

    Context: Recent authors have not found substantial evidence to support the use of static stretching for improving performance, so interest in dynamic warm-up procedures has risen. Our findings may improve the understanding of the acute effects of different types of pre-exercise protocols on performance and may help clinicians develop effective warm-up protocols for sports practice and competition. Objective: To examine the acute effects of 4 warm-up protocols with and without a weighted vest on anaerobic performance in female high school athletes. Design: Randomized, counterbalanced, repeated-measures design. Setting: High school fitness center. Patients or Other Participants: Eighteen healthy high school female athletes (age = 15.3 ± 1.2 years, height = 166.3 ± 9.1 cm, mass = 61.6 ± 10.4 kg). Intervention(s): After 5 minutes of jogging, subjects performed 4 randomly ordered warm-up protocols: (1) Five static stretches (2 × 30 seconds) (SS), (2) nine moderate-intensity to high-intensity dynamic exercises (DY), (3) the same 9 dynamic exercises performed with a vest weighted with 2% of body mass (DY2), and (4) the same 9 dynamic exercises performed with a vest weighted with 6% of body mass (DY6). Main Outcome Measure(s): Vertical jump, long jump, seated medicine ball toss, and 10-yard sprint. Results: Vertical jump performance was significantly greater after DY (41.3 ± 5.4 cm) and DY2 (42.1 ± 5.2 cm) compared with SS (37.1 ± 5.1 cm), and long jump performance was significantly greater after DY2 (180.5 ± 20.3 cm) compared with SS (160.4 ± 20.8 cm) ( P ≤ .05). No significant differences between trials were observed for the seated medicine ball toss or 10-yard sprint. Conclusions: A dynamic warm-up performed with a vest weighted with 2% of body mass may be the most effective warm-up protocol for enhancing jumping performance in high school female athletes. PMID:17273458

  11. Nonlinear least-squares data fitting in Excel spreadsheets.

    PubMed

    Kemmer, Gerdi; Keller, Sandro

    2010-02-01

    We describe an intuitive and rapid procedure for analyzing experimental data by nonlinear least-squares fitting (NLSF) in the most widely used spreadsheet program. Experimental data in x/y form and data calculated from a regression equation are inputted and plotted in a Microsoft Excel worksheet, and the sum of squared residuals is computed and minimized using the Solver add-in to obtain the set of parameter values that best describes the experimental data. The confidence of best-fit values is then visualized and assessed in a generally applicable and easily comprehensible way. Every user familiar with the most basic functions of Excel will be able to implement this protocol, without previous experience in data fitting or programming and without additional costs for specialist software. The application of this tool is exemplified using the well-known Michaelis-Menten equation characterizing simple enzyme kinetics. Only slight modifications are required to adapt the protocol to virtually any other kind of dataset or regression equation. The entire protocol takes approximately 1 h.

  12. Progress in Quantitative Viral Load Testing: Variability and Impact of the WHO Quantitative International Standards

    PubMed Central

    Sun, Y.; Tang, L.; Procop, G. W.; Hillyard, D. R.; Young, S. A.; Caliendo, A. M.

    2016-01-01

    ABSTRACT It has been hoped that the recent availability of WHO quantitative standards would improve interlaboratory agreement for viral load testing; however, insufficient data are available to evaluate whether this has been the case. Results from 554 laboratories participating in proficiency testing surveys for quantitative PCR assays of cytomegalovirus (CMV), Epstein-Barr virus (EBV), BK virus (BKV), adenovirus (ADV), and human herpesvirus 6 (HHV6) were evaluated to determine overall result variability and then were stratified by assay manufacturer. The impact of calibration to international units/ml (CMV and EBV) on variability was also determined. Viral loads showed a high degree of interlaboratory variability for all tested viruses, with interquartile ranges as high as 1.46 log10 copies/ml and the overall range for a given sample up to 5.66 log10 copies/ml. Some improvement in result variability was seen when international units were adopted. This was particularly the case for EBV viral load results. Variability in viral load results remains a challenge across all viruses tested here; introduction of international quantitative standards may help reduce variability and does so more or less markedly for certain viruses. PMID:27852673

  13. Systematic review and proposal of a field-based physical fitness-test battery in preschool children: the PREFIT battery.

    PubMed

    Ortega, Francisco B; Cadenas-Sánchez, Cristina; Sánchez-Delgado, Guillermo; Mora-González, José; Martínez-Téllez, Borja; Artero, Enrique G; Castro-Piñero, Jose; Labayen, Idoia; Chillón, Palma; Löf, Marie; Ruiz, Jonatan R

    2015-04-01

    Physical fitness is a powerful health marker in childhood and adolescence, and it is reasonable to think that it might be just as important in younger children, i.e. preschoolers. At the moment, researchers, clinicians and sport practitioners do not have enough information about which fitness tests are more reliable, valid and informative from the health point of view to be implemented in preschool children. Our aim was to systematically review the studies conducted in preschool children using field-based fitness tests, and examine their (1) reliability, (2) validity, and (3) relationship with health outcomes. Our ultimate goal was to propose a field-based physical fitness-test battery to be used in preschool children. PubMed and Web of Science. Studies conducted in healthy preschool children that included field-based fitness tests. When using PubMed, we included Medical Subject Heading (MeSH) terms to enhance the power of the search. A set of fitness-related terms were combined with 'child, preschool' [MeSH]. The same strategy and terms were used for Web of Science (except for the MeSH option). Since no previous reviews with a similar aim were identified, we searched for all articles published up to 1 April 2014 (no starting date). A total of 2,109 articles were identified, of which 22 articles were finally selected for this review. Most studies focused on reliability of the fitness tests (n = 21, 96%), while very few focused on validity (0 criterion-related validity and 4 (18%) convergent validity) or relationship with health outcomes (0 longitudinal and 1 (5%) cross-sectional study). Motor fitness, particularly balance, was the most studied fitness component, while cardiorespiratory fitness was the least studied. After analyzing the information retrieved in the current systematic review about fitness testing in preschool children, we propose the PREFIT battery, field-based FITness testing in PREschool children. The PREFIT battery is composed of the following

  14. Testing warning messages on smokers’ cigarette packages: A standardized protocol

    PubMed Central

    Brewer, Noel T.; Hall, Marissa G.; Lee, Joseph G. L.; Peebles, Kathryn; Noar, Seth M.; Ribisl, Kurt M.

    2015-01-01

    Purpose Lab experiments on cigarette warnings typically use a brief one-time exposure that is not paired with the cigarette packs smokers use every day, leaving open the question of how repeated warning exposure over several weeks may affect smokers. This proof of principle study sought to develop a new protocol for testing cigarette warnings that better reflects real-world exposure by presenting them on cigarette smokers’ own packs. Methods We tested a cigarette pack labeling protocol with 76 US smokers ages 18 and older. We applied graphic warnings to the front and back of smokers’ cigarette packs. Results Most smokers reported that at least 75% of the packs of cigarettes they smoked during the study had our warnings. Nearly all said they would participate in the study again. Using cigarette packs with the study warnings increased quit intentions (p<.05). Conclusion Our findings suggest a feasible pack labeling protocol with six steps: (1) schedule appointments at brief intervals; (2) determine typical cigarette consumption; (3) ask smokers to bring a supply of cigarette packs to study appointments; (4) apply labels to smokers’ cigarette packs; (5) provide participation incentives at the end of appointments; and (6) refer smokers to cessation services at end of the study. When used in randomized controlled trials in settings with real-world message exposure over time, this protocol may help identify the true impact of warnings and thus better inform tobacco product labeling policy. PMID:25564282

  15. FitSKIRT: genetic algorithms to automatically fit dusty galaxies with a Monte Carlo radiative transfer code

    NASA Astrophysics Data System (ADS)

    De Geyter, G.; Baes, M.; Fritz, J.; Camps, P.

    2013-02-01

    We present FitSKIRT, a method to efficiently fit radiative transfer models to UV/optical images of dusty galaxies. These images have the advantage that they have better spatial resolution compared to FIR/submm data. FitSKIRT uses the GAlib genetic algorithm library to optimize the output of the SKIRT Monte Carlo radiative transfer code. Genetic algorithms prove to be a valuable tool in handling the multi- dimensional search space as well as the noise induced by the random nature of the Monte Carlo radiative transfer code. FitSKIRT is tested on artificial images of a simulated edge-on spiral galaxy, where we gradually increase the number of fitted parameters. We find that we can recover all model parameters, even if all 11 model parameters are left unconstrained. Finally, we apply the FitSKIRT code to a V-band image of the edge-on spiral galaxy NGC 4013. This galaxy has been modeled previously by other authors using different combinations of radiative transfer codes and optimization methods. Given the different models and techniques and the complexity and degeneracies in the parameter space, we find reasonable agreement between the different models. We conclude that the FitSKIRT method allows comparison between different models and geometries in a quantitative manner and minimizes the need of human intervention and biasing. The high level of automation makes it an ideal tool to use on larger sets of observed data.

  16. Test-retest and interobserver reliability of quantitative sensory testing according to the protocol of the German Research Network on Neuropathic Pain (DFNS): a multi-centre study.

    PubMed

    Geber, Christian; Klein, Thomas; Azad, Shahnaz; Birklein, Frank; Gierthmühlen, Janne; Huge, Volker; Lauchart, Meike; Nitzsche, Dorothee; Stengel, Maike; Valet, Michael; Baron, Ralf; Maier, Christoph; Tölle, Thomas; Treede, Rolf-Detlef

    2011-03-01

    Quantitative sensory testing (QST) is an instrument to assess positive and negative sensory signs, helping to identify mechanisms underlying pathologic pain conditions. In this study, we evaluated the test-retest reliability (TR-R) and the interobserver reliability (IO-R) of QST in patients with sensory disturbances of different etiologies. In 4 centres, 60 patients (37 male and 23 female, 56.4±1.9years) with lesions or diseases of the somatosensory system were included. QST comprised 13 parameters including detection and pain thresholds for thermal and mechanical stimuli. QST was performed in the clinically most affected test area and a less or unaffected control area in a morning and an afternoon session on 2 consecutive days by examiner pairs (4 QSTs/patient). For both, TR-R and IO-R, there were high correlations (r=0.80-0.93) at the affected test area, except for wind-up ratio (TR-R: r=0.67; IO-R: r=0.56) and paradoxical heat sensations (TR-R: r=0.35; IO-R: r=0.44). Mean IO-R (r=0.83, 31% unexplained variance) was slightly lower than TR-R (r=0.86, 26% unexplained variance, P<.05); the difference in variance amounted to 5%. There were no differences between study centres. In a subgroup with an unaffected control area (n=43), reliabilities were significantly better in the test area (TR-R: r=0.86; IO-R: r=0.83) than in the control area (TR-R: r=0.79; IO-R: r=0.71, each P<.01), suggesting that disease-related systematic variance enhances reliability of QST. We conclude that standardized QST performed by trained examiners is a valuable diagnostic instrument with good test-retest and interobserver reliability within 2days. With standardized training, observer bias is much lower than random variance. Quantitative sensory testing performed by trained examiners is a valuable diagnostic instrument with good interobserver and test-retest reliability for use in patients with sensory disturbances of different etiologies to help identify mechanisms of neuropathic and non

  17. A goodness-of-fit test for occupancy models with correlated within-season revisits

    USGS Publications Warehouse

    Wright, Wilson; Irvine, Kathryn M.; Rodhouse, Thomas J.

    2016-01-01

    Occupancy modeling is important for exploring species distribution patterns and for conservation monitoring. Within this framework, explicit attention is given to species detection probabilities estimated from replicate surveys to sample units. A central assumption is that replicate surveys are independent Bernoulli trials, but this assumption becomes untenable when ecologists serially deploy remote cameras and acoustic recording devices over days and weeks to survey rare and elusive animals. Proposed solutions involve modifying the detection-level component of the model (e.g., first-order Markov covariate). Evaluating whether a model sufficiently accounts for correlation is imperative, but clear guidance for practitioners is lacking. Currently, an omnibus goodnessof- fit test using a chi-square discrepancy measure on unique detection histories is available for occupancy models (MacKenzie and Bailey, Journal of Agricultural, Biological, and Environmental Statistics, 9, 2004, 300; hereafter, MacKenzie– Bailey test). We propose a join count summary measure adapted from spatial statistics to directly assess correlation after fitting a model. We motivate our work with a dataset of multinight bat call recordings from a pilot study for the North American Bat Monitoring Program. We found in simulations that our join count test was more reliable than the MacKenzie–Bailey test for detecting inadequacy of a model that assumed independence, particularly when serial correlation was low to moderate. A model that included a Markov-structured detection-level covariate produced unbiased occupancy estimates except in the presence of strong serial correlation and a revisit design consisting only of temporal replicates. When applied to two common bat species, our approach illustrates that sophisticated models do not guarantee adequate fit to real data, underscoring the importance of model assessment. Our join count test provides a widely applicable goodness-of-fit test and

  18. Validity of a Newly-Designed Rectilinear Stepping Ergometer Submaximal Exercise Test to Assess Cardiorespiratory Fitness

    PubMed Central

    Zhang, Rubin; Zhan, Likui; Sun, Shaoming; Peng, Wei; Sun, Yining

    2017-01-01

    The maximum oxygen uptake (V̇O2 max), determined from graded maximal or submaximal exercise tests, is used to classify the cardiorespiratory fitness level of individuals. The purpose of this study was to examine the validity and reliability of the YMCA submaximal exercise test protocol performed on a newly-designed rectilinear stepping ergometer (RSE) that used up and down reciprocating vertical motion in place of conventional circular motion and giving precise measurement of workload, to determine V̇O2 max in young healthy male adults. Thirty-two young healthy male adults (32 males; age range: 20-35 years; height: 1.75 ± 0.05 m; weight: 67.5 ± 8.6 kg) firstly participated in a maximal-effort graded exercise test using a cycle ergometer (CE) to directly obtain measured V̇O2 max. Subjects then completed the progressive multistage test on the RSE beginning at 50W and including additional stages of 70, 90, 110, 130, and 150W, and the RSE YMCA submaximal test consisting of a workload increase every 3 minutes until the termination criterion was reached. A metabolic equation was derived from the RSE multistage exercise test to predict oxygen consumption (V̇O2) from power output (W) during the submaximal exercise test (V̇O2 (mL·min-1 )=12.4 ×W(watts)+3.5 mL·kg-1·min-1×M+160mL·min-1, R2= 0.91, standard error of the estimate (SEE) = 134.8mL·min-1). A high correlation was observed between the RSE YMCA estimated V̇O2 max and the CE measured V̇O2 max (r=0.87). The mean difference between estimated and measured V̇O2 max was 2.5 mL·kg-1·min-1, with an SEE of 3.55 mL·kg-1·min-1. The data suggest that the RSE YMCA submaximal exercise test is valid for predicting V̇O2 max in young healthy male adults. The findings show that the rectilinear stepping exercise is an effective submaximal exercise for predicting V̇O2 max. The newly-designed RSE may be potentially further developed as an alternative ergometer for assessing cardiorespiratory fitness and the

  19. Fitness determinants of repeated-sprint ability in highly trained youth football players.

    PubMed

    Spencer, Matt; Pyne, David; Santisteban, Juanma; Mujika, Iñigo

    2011-12-01

    Variations in rates of growth and development in young football players can influence relationships among various fitness qualities. To investigate the relationships between repeated-sprint ability and other fundamental fitness qualities of acceleration, agility, explosive leg power, and aerobic conditioning through the age groups of U11 to U18 in highly trained junior football players. Male players (n = 119) across the age groups completed a fitness assessment battery over two testing sessions. The first session consisted of countermovement jumps without and with arm swing, 15-m sprint run, 15-m agility run, and the 20-m Shuttle Run (U11 to U15) or the Yo-Yo Intermittent Recovery Test, Level 1 (U16 to U18). The players were tested for repeated-sprint ability in the second testing session using a protocol of 6 × 30-m sprints on 30 s with an active recovery. The correlations of repeated-sprint ability with the assorted fitness tests varied considerably between the age groups, especially for agility (r = .02 to .92) and explosive leg power (r = .04 to .84). Correlations of repeated sprint ability with acceleration (r = .48 to .93) and aerobic conditioning (r = .28 to .68) were less variable with age. Repeated-sprint ability associates differently with other fundamental fitness tests throughout the teenage years in highly trained football players, although stabilization of these relationships occurs by the age of 18 y. Coaches in junior football should prescribe physical training accounting for variations in short-term disruptions or impairment of physical performance during this developmental period.

  20. COMPARATIVE TOXICITY TESTING OF SELECTED BENTHIC AND EPIBENTHIC ORGANISMS FOR THE DEVELOPMENT OF SEDIMENT QUALITY TEST PROTOCOLS

    EPA Science Inventory

    Sediment contamination has resulted in the need to develop an appropriate suite of toxicity tests to assess ecotoxicological impacts on estuarine ecosystems. Existing Environmental Protection Agency (EPA) protocols recommend a number of test organisms, including amphipods, polych...

  1. A note on Poisson goodness-of-fit tests for ionizing radiation induced chromosomal aberration samples.

    PubMed

    Higueras, Manuel; González, J E; Di Giorgio, Marina; Barquinero, J F

    2018-06-13

    To present Poisson exact goodness-of-fit tests as alternatives and complements to the asymptotic u-test, which is the most widely used in cytogenetic biodosimetry, to decide whether a sample of chromosomal aberrations in blood cells comes from an homogeneous or inhomogeneous exposure. Three Poisson exact goodness-of-fit test from the literature are introduced and implemented in the R environment. A Shiny R Studio application, named GOF Poisson, has been updated for the purpose of giving support to this work. The three exact tests and the u-test are applied in chromosomal aberration data from clinical and accidental radiation exposure patients. It is observed how the u-test is not an appropriate approximation in small samples with small yield of chromosomal aberrations. Tools are provided to compute the three exact tests, which is not as trivial as the implementation of the u-test. Poisson exact goodness-of-fit tests should be considered jointly to the u-test for detecting inhomogeneous exposures in the cytogenetic biodosimetry practice.

  2. Corrected goodness-of-fit test in covariance structure analysis.

    PubMed

    Hayakawa, Kazuhiko

    2018-05-17

    Many previous studies report simulation evidence that the goodness-of-fit test in covariance structure analysis or structural equation modeling suffers from the overrejection problem when the number of manifest variables is large compared with the sample size. In this study, we demonstrate that one of the tests considered in Browne (1974) can address this long-standing problem. We also propose a simple modification of Satorra and Bentler's mean and variance adjusted test for non-normal data. A Monte Carlo simulation is carried out to investigate the performance of the corrected tests in the context of a confirmatory factor model, a panel autoregressive model, and a cross-lagged panel (panel vector autoregressive) model. The simulation results reveal that the corrected tests overcome the overrejection problem and outperform existing tests in most cases. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  3. A comparative study of two protocols for treadmill walking exercise testing in ambulating subjects with incomplete spinal cord injury.

    PubMed

    Lundgaard, E; Wouda, M F; Strøm, V

    2017-10-01

    This is a comparative study of two exercise testing protocols. The objective of this study was to compare maximal oxygen uptake (VO 2 max) and achieved criteria for maximal exercise testing between the Sunnaas Protocol-a newly designed treadmill exercise test protocol-and the Modified Bruce Protocol in persons with incomplete spinal cord injury (SCI). This study was conducted in Sunnaas Rehabilitation Hospital, Norway. Twenty persons (19 men) with incomplete SCI (AIS D) capable of ambulating without assistive devices performed two treadmill walking exercise tests (Sunnaas Protocol and Modified Bruce Protocol) until exhaustion 1-3 days apart. The key differences between the protocols are the smaller increments in speed and shorter duration on each workload in the Sunnaas Protocol. Cardiovascular responses were measured continuously throughout both tests. The subjects exhibited statistically significantly higher VO 2 max when using the Sunnaas Protocol (37.1±9.9 vs 35.4±9.8 ml kg -1  min -1 , P=0.01), with a mean between-test difference of 1.8 ml kg -1  min -1 (95% confidence interval: 0.49-3.16). There was no significant difference in mean maximal heart rate (HR max). Nineteen (95%) subjects achieved at least three of the four criteria for maximal oxygen uptake using the Sunnaas Protocol. Thirteen (65%) subjects achieved at least three of the criteria using a Modified Bruce protocol. The small differences in both VO 2 max and achieved criteria in favor of the Sunnaas Protocol suggest that it could be a useful alternative treadmill exercise test protocol for ambulating persons with incomplete SCI.

  4. Developing patient-centered treatment protocols in brain stimulation: a rationale for combining quantitative and qualitative approaches in persons with HIV.

    PubMed

    Rosedale, Mary; Malaspina, Dolores; Malamud, Daniel; Strauss, Shiela M; Horne, Jaclyn D; Abouzied, Salman; Cruciani, Ricardo A; Knotkova, Helena

    2012-01-01

    This article reports and discusses how quantitative (physiological and behavioral) and qualitative methods are being combined in an open-label pilot feasibility study. The study evaluates safety, tolerability, and acceptability of a protocol to treat depression in HIV-infected individuals, using a 2-week block of transcranial direct current stimulation (tDCS) over the dorsolateral prefrontal cortex. Major depressive disorder (MDD) is the second most prevalent psychiatric disorder after substance abuse among HIV-positive adults, and novel antidepressant treatments are needed for this vulnerable population. The authors describe the challenges and contributions derived from different research perspectives and methodological approaches and provide a philosophical framework for combining quantitative and qualitative measurements for a fuller examination of the disorder. Four methodological points are presented: (1) the value of combining quantitative and qualitative approaches; (2) the need for context-specific measures when studying patients with medical and psychiatric comorbidities; (3) the importance of research designs that integrate physiological, behavioral, and qualitative approaches when evaluating novel treatments; and (4) the need to explore the relationships between biomarkers, clinical symptom assessments, patient self-evaluations, and patient experiences when developing new, patient-centered protocols. The authors conclude that the complexity of studying novel treatments in complex and new patient populations requires complex research designs to capture the richness of data that inform translational research.

  5. A policy-driven multifaceted approach for early childhood physical fitness promotion: impacts on body composition and physical fitness in young Chinese children.

    PubMed

    Zhou, Zhixiong; Ren, Hong; Yin, Zenong; Wang, Lihong; Wang, Kaizhen

    2014-05-05

    The prevalence of obesity increased while certain measures of physical fitness deteriorated in preschool children in China over the past decade. This study tested the effectiveness of a multifaceted intervention that integrated childcare center, families, and community to promote healthy growth and physical fitness in preschool Chinese children. This 12-month study was conducted using a quasi-experimental pretest/posttest design with comparison group. The participants were 357 children (mean age = 4.5 year) enrolled in three grade levels in two childcare centers in Beijing, China. The intervention included: 1) childcare center intervention (physical activity policy changes, teacher training, physical education curriculum and food services training), 2) family intervention (parent education, internet website for support, and family events), and 3) community intervention (playground renovation and community health promotion events). The study outcome measures included body composition (percent body fat, fat mass, and muscle mass), Body Mass Index (BMI) and BMI z-score and physical fitness scores in 20-meter agility run (20M-AR), broad jump for distance (BJ), timed 10-jumps, tennis ball throwing (TBT), sit and reach (SR), balance beam walk (BBW), 20-meter crawl (20M-C)), 30-meter sprint (30M-S)) from a norm referenced test. Measures of process evaluation included monitoring of children's physical activity (activity time and intensity) and food preparation records, and fidelity of intervention protocol implementation. Children in the intervention center significantly lowered their body fat percent (-1.2%, p < 0.0001), fat mass (-0.55 kg, p <0.0001), and body weight (0.36 kg, p <0.02) and increased muscle mass (0.48 kg, p <0.0001), compared to children in the control center. They also improved all measures of physical fitness except timed 10-jumps (20M-AR: -0.74 seconds, p < 0.0001; BJ: 8.09 cm, p < 0.0001; TBT: 0.52 meters, p < 0.006; SR: 0.88 cm, p < 0.03; BBW: -2

  6. Evaluation of I-FIT results and machine variability using MnRoad test track mixtures.

    DOT National Transportation Integrated Search

    2017-06-01

    The Illinois Flexibility Index Test (I-FIT) was developed to distinguish between different mixtures in terms of potential cracking. Several : machines were manufactured and are currently available to perform the I-FIT. This report presents the result...

  7. 76 FR 50164 - Protocol Gas Verification Program and Minimum Competency Requirements for Air Emission Testing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-12

    ...-AQ06 Protocol Gas Verification Program and Minimum Competency Requirements for Air Emission Testing... correct certain portions of the Protocol Gas Verification Program and Minimum Competency Requirements for... final rule that amends the Agency's Protocol Gas Verification Program (PGVP) and the minimum competency...

  8. Goodness-Of-Fit Test for Nonparametric Regression Models: Smoothing Spline ANOVA Models as Example.

    PubMed

    Teran Hidalgo, Sebastian J; Wu, Michael C; Engel, Stephanie M; Kosorok, Michael R

    2018-06-01

    Nonparametric regression models do not require the specification of the functional form between the outcome and the covariates. Despite their popularity, the amount of diagnostic statistics, in comparison to their parametric counter-parts, is small. We propose a goodness-of-fit test for nonparametric regression models with linear smoother form. In particular, we apply this testing framework to smoothing spline ANOVA models. The test can consider two sources of lack-of-fit: whether covariates that are not currently in the model need to be included, and whether the current model fits the data well. The proposed method derives estimated residuals from the model. Then, statistical dependence is assessed between the estimated residuals and the covariates using the HSIC. If dependence exists, the model does not capture all the variability in the outcome associated with the covariates, otherwise the model fits the data well. The bootstrap is used to obtain p-values. Application of the method is demonstrated with a neonatal mental development data analysis. We demonstrate correct type I error as well as power performance through simulations.

  9. Quantitative Testing of Bedrock Incision Models, Clearwater River, WA

    NASA Astrophysics Data System (ADS)

    Tomkin, J. H.; Brandon, M.; Pazzaglia, F.; Barbour, J.; Willet, S.

    2001-12-01

    The topographic evolution of many active orogens is dominated by the process of bedrock channel incision. Several incision models based around the detachment limited shear-stress model (or stream power model) which employs an area (A) and slope (S) power law (E = K Sn Am) have been proposed to explain this process. They require quantitative assessment. We evaluate the proposed incision models by comparing their predictions with observations obtained from a river in a tectonically active mountain range: the Clearwater River in northwestern Washington State. Previous work on river terraces along the Clearwater have provided long-term incision rates for the river, and in conjunction with previous fission track studies it has also been determined that there is a long-term balance between river incision and rock uplift. This steady-state incision rate data allows us, through the use of inversion methods and statistical tests, to determine the applicability of the different incision models for the Clearwater. None of the models successfully explain the observations. This conclusion particularly applies to the commonly used detachment limited shear-stress model (or stream power model), which has a physically implausible best fit solution and systematic residuals for all the predicted combinations of m and n.

  10. Specificity and false positive rates of the Test of Memory Malingering, Rey 15-item Test, and Rey Word Recognition Test among forensic inpatients with intellectual disabilities.

    PubMed

    Love, Christopher M; Glassmire, David M; Zanolini, Shanna Jordan; Wolf, Amanda

    2014-10-01

    This study evaluated the specificity and false positive (FP) rates of the Rey 15-Item Test (FIT), Word Recognition Test (WRT), and Test of Memory Malingering (TOMM) in a sample of 21 forensic inpatients with mild intellectual disability (ID). The FIT demonstrated an FP rate of 23.8% with the standard quantitative cutoff score. Certain qualitative error types on the FIT showed promise and had low FP rates. The WRT obtained an FP rate of 0.0% with previously reported cutoff scores. Finally, the TOMM demonstrated low FP rates of 4.8% and 0.0% on Trial 2 and the Retention Trial, respectively, when applying the standard cutoff score. FP rates are reported for a range of cutoff scores and compared with published research on individuals diagnosed with ID. Results indicated that although the quantitative variables on the FIT had unacceptably high FP rates, the TOMM and WRT had low FP rates, increasing the confidence clinicians can place in scores reflecting poor effort on these measures during ID evaluations. © The Author(s) 2014.

  11. A 96-well-plate-based optical method for the quantitative and qualitative evaluation of Pseudomonas aeruginosa biofilm formation and its application to susceptibility testing.

    PubMed

    Müsken, Mathias; Di Fiore, Stefano; Römling, Ute; Häussler, Susanne

    2010-08-01

    A major reason for bacterial persistence during chronic infections is the survival of bacteria within biofilm structures, which protect cells from environmental stresses, host immune responses and antimicrobial therapy. Thus, there is concern that laboratory methods developed to measure the antibiotic susceptibility of planktonic bacteria may not be relevant to chronic biofilm infections, and it has been suggested that alternative methods should test antibiotic susceptibility within a biofilm. In this paper, we describe a fast and reliable protocol for using 96-well microtiter plates for the formation of Pseudomonas aeruginosa biofilms; the method is easily adaptable for antimicrobial susceptibility testing. This method is based on bacterial viability staining in combination with automated confocal laser scanning microscopy. The procedure simplifies qualitative and quantitative evaluation of biofilms and has proven to be effective for standardized determination of antibiotic efficiency on P. aeruginosa biofilms. The protocol can be performed within approximately 60 h.

  12. Laboratory Testing Protocols for Heparin-Induced Thrombocytopenia (HIT) Testing.

    PubMed

    Lau, Kun Kan Edwin; Mohammed, Soma; Pasalic, Leonardo; Favaloro, Emmanuel J

    2017-01-01

    Heparin-induced thrombocytopenia (HIT) represents a significant high morbidity complication of heparin therapy. The clinicopathological diagnosis of HIT remains challenging for many reasons; thus, laboratory testing represents an important component of an accurate diagnosis. Although there are many assays available to assess HIT, these essentially fall into two categories-(a) immunological assays, and (b) functional assays. The current chapter presents protocols for several HIT assays, being those that are most commonly performed in laboratory practice and have the widest geographic distribution. These comprise a manual lateral flow-based system (STiC), a fully automated latex immunoturbidimetric assay, a fully automated chemiluminescent assay (CLIA), light transmission aggregation (LTA), and whole blood aggregation (Multiplate).

  13. A Methodology and Software Environment for Testing Process Model’s Sequential Predictions with Protocols

    DTIC Science & Technology

    1992-12-21

    in preparation). Foundations of artificial intelligence. Cambridge, MA: MIT Press. O’Reilly, R. C. (1991). X3DNet: An X- Based Neural Network ...2.2.3 Trace based protocol analysis 19 2.2A Summary of important data features 21 2.3 Tools related to process model testing 23 2.3.1 Tools for building...algorithm 57 3. Requirements for testing process models using trace based protocol 59 analysis 3.1 Definition of trace based protocol analysis (TBPA) 59

  14. Sensitive Quantitative Assessment of Balance Disorders

    NASA Technical Reports Server (NTRS)

    Paloski, Willilam H.

    2007-01-01

    Computerized dynamic posturography (CDP) has become a standard technique for objectively quantifying balance control performance, diagnosing the nature of functional impairments underlying balance disorders, and monitoring clinical treatment outcomes. We have long used CDP protocols to assess recovery of sensory-motor function in astronauts following space flight. The most reliable indicators of post-flight crew performance are the sensory organization tests (SOTs), particularly SOTs 5 and 6, which are sensitive to changes in availability and/or utilization of vestibular cues. We have noted, however, that some astronauts exhibiting obvious signs of balance impairment after flight are able to score within clinical norms on these tests, perhaps as a result of adopting competitive strategies or by their natural skills at substituting alternate sensory information sources. This insensitivity of the CDP protocol could underestimate of the degree of impairment and, perhaps, lead to premature release of those crewmembers to normal duties. To improve the sensitivity of the CDP protocol we have introduced static and dynamic head tilt SOT trials into our protocol. The pattern of postflight recovery quantified by the enhanced CDP protocol appears to more aptly track the re-integration of sensory-motor function, with recovery time increasing as the complexity of sensory-motor/biomechanical task increases. The new CDP protocol therefore seems more suitable for monitoring post-flight sensory-motor recovery and for indicating to crewmembers and flight surgeons fitness for return to duty and/or activities of daily living. There may be classes of patients (e.g., athletes, pilots) having motivation and/or performance characteristics similar to astronauts whose sensory-motor treatment outcomes would also be more accurately monitored using the enhanced CDP protocol. Furthermore, the enhanced protocol may be useful in early detection of age-related balance disorders.

  15. Association between physical activity, sedentary behavior, and fitness with health related quality of life in healthy children and adolescents: A protocol for a systematic review and meta-analysis.

    PubMed

    Bermejo-Cantarero, Alberto; Álvarez-Bueno, Celia; Martinez-Vizcaino, Vicente; García-Hermoso, Antonio; Torres-Costoso, Ana Isabel; Sánchez-López, Mairena

    2017-03-01

    Health related quality of life (HRQoL) is a subjective, multidimensional and changing over time construct. When HRQoL is decreased, a child is less likely to be able to develop normally and mature into a healthy adult. Physical inactivity is a priority public health problem. Evidence suggests how even moderate levels of physical activity or high fitness levels are associated with benefits for the health in children and adolescents. The aims of this systematic review are to examine the evidence about the relationship between physical activity, sedentary behavior, and fitness with HRQoL, and estimate the effects of interventions that have tested the effectiveness of the increase of the physical activity, the improvement of the physical fitness or the avoidance of sedentary behaviors in HRQoL in healthy subjects aged under 18 years old. This systematic review and meta-analysis protocol was conducted following the preferred reporting items for systematic review and meta-analysis protocols (PRISMA-P) statement. To identify relevant studies, the following electronic databases will be searched: MEDLINE, EMBASE, Cochrane Database, Web of Science, and PEDro. Reference lists of relevant studies will be examined for links to potential related articles. The methodological quality of the observational included studies will be scored using a quality assessment checklist. For the intervention studies, the risk of bias will be estimated using The Cochrane Collaboration tool for assessing risk of bias. Reviewers will determine whether a meta-analysis is possible when data have been extracted. If it is, subgroup analyses will be carried out by age and socioeconomic status, and by the different dimensions of the HRQoL. If is not possible, a descriptive analysis will be conducted. To our knowledge, this systematic review and meta-analysis will be the first that synthesizes the existing results about the relationship between physical activity, sedentary behavior, physical fitness, and

  16. The Marine Corps Physical Fitness Test: The Need to Replace it with a Combat Fitness Test

    DTIC Science & Technology

    2008-02-19

    unforeseen emergencies.”1 Crossfit , a website-based workout program, has popularized the en vogue, yet relatively old concept of “functional fitness...Sports; 1996. <http://www.cdc.gov/nccdphp/sgr/sgr.htm> 2 Greg Glassman, “What is Fitness?” Crossfit Journal, October 2002, 1-2. 3 human...short, intense workouts aimed at increasing power, speed, and strength. Additionally, Crossfit explains the crossover between the three pathways

  17. Validity of the modified back-saver sit-and-reach test: a comparison with other protocols.

    PubMed

    Hui, S S; Yuen, P Y

    2000-09-01

    Studies have shown that the classical sit-and-reach (CSR) test, the modified sit-and-reach (MSR), and the newly developed back-saver sit-and-reach (BS) test have poor criterion-related validity in estimating low-back flexibility but yielded moderate criterion-related validity in hamstring flexibility. The V sit-and-reach (VSR) test was found to be practical but the validity has not been established. The purpose of this study was to propose a modified back-saver sit-and-reach (MBS) test, which incorporated all advantages of the various protocols, and to compare the criterion-related validity and reliability of all these tests. 158 college students (F = 96, and M = 62; age = 20.77 +/- 2.51) performed CSR, VSR, BS (left and right leg), and MBS (left and right leg) tests in a randomized order. Scores from each test were then correlated with the criterion measures. For all sit-reach tests, intraclass reliability (single trial) was very high (r = 0.89-0.98). MBS yielded significant and highest r with low-back and hamstring criterion for men (r = 0.47-0.67) and women (r = 0.23-0.54). The low-back and right hamstring validity of MBS for men were significantly (P < 0.01) higher than those from BS and CSR, whereas no differences in criterion-related validity were found between the MBS and other protocols in women. The ratings of perceived comfort among the sit-and-reach protocols were significantly different (P < 0.001) from each other. The rating for MBS was observed the most comfortable test as compared with other protocols. The MBS test is not only a reliable test for hamstring and low-back flexibility, it is also a more practical with improved validity for hamstring and low-back flexibility in men than previous protocols.

  18. Application of Titration-Based Screening for the Rapid Pilot Testing of High-Throughput Assays.

    PubMed

    Zhang, Ji-Hu; Kang, Zhao B; Ardayfio, Ophelia; Ho, Pei-i; Smith, Thomas; Wallace, Iain; Bowes, Scott; Hill, W Adam; Auld, Douglas S

    2014-06-01

    Pilot testing of an assay intended for high-throughput screening (HTS) with small compound sets is a necessary but often time-consuming step in the validation of an assay protocol. When the initial testing concentration is less than optimal, this can involve iterative testing at different concentrations to further evaluate the pilot outcome, which can be even more time-consuming. Quantitative HTS (qHTS) enables flexible and rapid collection of assay performance statistics, hits at different concentrations, and concentration-response curves in a single experiment. Here we describe the qHTS process for pilot testing in which eight-point concentration-response curves are produced using an interplate asymmetric dilution protocol in which the first four concentrations are used to represent the range of typical HTS screening concentrations and the last four concentrations are added for robust curve fitting to determine potency/efficacy values. We also describe how these data can be analyzed to predict the frequency of false-positives, false-negatives, hit rates, and confirmation rates for the HTS process as a function of screening concentration. By taking into account the compound pharmacology, this pilot-testing paradigm enables rapid assessment of the assay performance and choosing the optimal concentration for the large-scale HTS in one experiment. © 2013 Society for Laboratory Automation and Screening.

  19. Modified telomeric repeat amplification protocol: a quantitative radioactive assay for telomerase without using electrophoresis.

    PubMed

    Szatmari, I; Tókés, S; Dunn, C B; Bardos, T J; Aradi, J

    2000-06-15

    A polymerase chain reaction (PCR)-based radioactive telomerase assay was developed in our laboratory which is quantitative and does not require electrophoretic evaluation (designated as TP-TRAP; it utilizes two reverse primers). The main steps of the assay include (1) extension of a 20-mer oligonucleotide substrate (MTS) by telomerase, (2) amplification of the telomerase products in the presence of [(3)H]dTTP using the substrate oligonucleotide and two reverse primers (RPC3, 38 mer; RP, 20 mer), (3) isolation of the amplified radioactive dsDNA by precipitation and filtration, (4) determination of the radioactivity of the acid-insoluble DNA. The length of the telomerase products does not increase on amplification. This valuable feature of the assay is achieved by utilization of the two reverse primers and a highly specific PCR protocol. The assay is linear, accurate, and suitable for cell-biological studies where slight quantitative differences in telomerase activity must be detected. The assay is also suitable for screening and characterization of telomerase inhibitors, as shown with a chemically modified oligonucleotide reverse transcriptase inhibitor [(s(4)dU)(35)]. Copyright 2000 Academic Press.

  20. Limited-information goodness-of-fit testing of diagnostic classification item response models.

    PubMed

    Hansen, Mark; Cai, Li; Monroe, Scott; Li, Zhen

    2016-11-01

    Despite the growing popularity of diagnostic classification models (e.g., Rupp et al., 2010, Diagnostic measurement: theory, methods, and applications, Guilford Press, New York, NY) in educational and psychological measurement, methods for testing their absolute goodness of fit to real data remain relatively underdeveloped. For tests of reasonable length and for realistic sample size, full-information test statistics such as Pearson's X 2 and the likelihood ratio statistic G 2 suffer from sparseness in the underlying contingency table from which they are computed. Recently, limited-information fit statistics such as Maydeu-Olivares and Joe's (2006, Psychometrika, 71, 713) M 2 have been found to be quite useful in testing the overall goodness of fit of item response theory models. In this study, we applied Maydeu-Olivares and Joe's (2006, Psychometrika, 71, 713) M 2 statistic to diagnostic classification models. Through a series of simulation studies, we found that M 2 is well calibrated across a wide range of diagnostic model structures and was sensitive to certain misspecifications of the item model (e.g., fitting disjunctive models to data generated according to a conjunctive model), errors in the Q-matrix (adding or omitting paths, omitting a latent variable), and violations of local item independence due to unmodelled testlet effects. On the other hand, M 2 was largely insensitive to misspecifications in the distribution of higher-order latent dimensions and to the specification of an extraneous attribute. To complement the analyses of the overall model goodness of fit using M 2 , we investigated the utility of the Chen and Thissen (1997, J. Educ. Behav. Stat., 22, 265) local dependence statistic XLD2 for characterizing sources of misfit, an important aspect of model appraisal often overlooked in favour of overall statements. The XLD2 statistic was found to be slightly conservative (with Type I error rates consistently below the nominal level) but still useful

  1. Health Worker Compliance with a ‘Test And Treat’ Malaria Case Management Protocol in Papua New Guinea

    PubMed Central

    Pulford, Justin; Smith, Iso; Mueller, Ivo; Siba, Peter M.; Hetzel, Manuel W.

    2016-01-01

    The Papua New Guinea (PNG) Department of Health introduced a ‘test and treat’ malaria case management protocol in 2011. This study assesses health worker compliance with the test and treat protocol on a wide range of measures, examines self-reported barriers to health worker compliance as well as health worker attitudes towards the test and treat protocol. Data were collected by cross-sectional survey conducted in randomly selected primary health care facilities in 2012 and repeated in 2014. The combined survey data included passive observation of current or recently febrile patients (N = 771) and interviewer administered questionnaires completed with health workers (N = 265). Across the two surveys, 77.6% of patients were tested for malaria infection by rapid diagnostic test (RDT) or microscopy, 65.6% of confirmed malaria cases were prescribed the correct antimalarials and 15.3% of febrile patients who tested negative for malaria infection were incorrectly prescribed an antimalarial. Overall compliance with a strictly defined test and treat protocol was 62.8%. A reluctance to test current/recently febrile patients for malaria infection by RDT or microscopy in the absence of acute malaria symptoms, reserving recommended antimalarials for confirmed malaria cases only and choosing to clinically diagnose a malaria infection, despite a negative RDT result were the most frequently reported barriers to protocol compliance. Attitudinal support for the test and treat protocol, as assessed by a nine-item measure, improved across time. In conclusion, health worker compliance with the full test and treat malaria protocol requires improvement in PNG and additional health worker support will likely be required to achieve this. The broader evidence base would suggest any such support should be delivered over a longer period of time, be multi-dimensional and multi-modal. PMID:27391594

  2. Protocols for hyperlactatemia induction in the lactate minimum test adapted to swimming rats.

    PubMed

    de Araujo, Gustavo Gomes; Papoti, Marcelo; Manchado, Fúlvia de Barros; de Mello, Maria Alice Rostom; Gobatto, Claudio Alexandre

    2007-12-01

    The lactate minimum test (LACmin) has been considered an important indicator of endurance exercise capacity and a single session protocol can predict the maximal steady state lactate (MLSS). The objective of this study was to determine the best swimming protocol to induce hyperlactatemia in order to assure the LACmin in rats (Rattus norvegicus), standardized to four different protocols (P) of lactate elevation. The protocols were P1: 6 min of intermittent jumping exercise in water (load of 50% of the body weight - bw); P2: two 13% bw load swimming bouts until exhaustion (tlim); P3: one tlim 13% bw load swimming bout; and P4: two 13% bw load swimming bouts (1st 30 s, 2nd to tlim), separated by a 30 s interval. The incremental phase of LACmin beginning with initial loads of 4% bw, increased in 0.5% at each 5 min. Peak lactate concentration was collected after 5, 7 and 9 min (mmol L(-1)) and differed among the protocols P1 (15.2+/-0.4, 14.9+/-0.7, 14.8+/-0.6) and P2 (14.0+/-0.4, 14.9+/-0.4, 15.5+/-0.5) compared to P3 (5.1+/-0.1, 5.6+/-0.3, 5.6+/-0.3) and P4 (4.7+/-0.2, 6.8+/-0.2, 7.1+/-0.2). The LACmin determination success rates were 58%, 55%, 80% and 91% in P1, P2, P3 and P4 protocols, respectively. The MLSS did not differ from LACmin in any protocol. The LACmin obtained from P4 protocol showed better assurance for the MLSS identification in most of the tested rats.

  3. Comparative Evaluation of Quantitative Test Methods for Gases on a Hard Surface

    DTIC Science & Technology

    2017-02-01

    COMPARATIVE EVALUATION OF QUANTITATIVE TEST METHODS FOR GASES ON A HARD SURFACE ECBC-TR-1426 Vipin Rastogi...1 COMPARATIVE EVALUATION OF QUANTITATIVE TEST METHODS FOR GASES ON A HARD SURFACE 1. INTRODUCTION Members of the U.S. Environmental...Generator 4 2.4 Experimental Design Each quantitative method was performed three times on three consecutive days. For the CD runs, three

  4. Comparative evaluation of two quantitative test methods for determining the efficacy of liquid sporicides and sterilants on a hard surface: a precollaborative study.

    PubMed

    Tomasino, Stephen F; Hamilton, Martin A

    2007-01-01

    Two quantitative carrier-based test methods for determining the efficacy of liquid sporicides and sterilants on a hard surface, the Standard Quantitative Carrier Test Method-ASTM E 2111-00 and an adaptation of a quantitative micro-method as reported by Sagripanti and Bonifacino, were compared in this study. The methods were selected based on their desirable characteristics (e.g., well-developed protocol, previous use with spores, fully quantitative, and use of readily available equipment) for testing liquid sporicides and sterilants on a hard surface. In this paper, the Sagripanti-Bonifacino procedure is referred to as the Three Step Method (TSM). AOAC Official Method 966.04 was included in this study as a reference method. Three laboratories participated in the evaluation. Three chemical treatments were tested: (1) 3000 ppm sodium hypochlorite with pH adjusted to 7.0, (2) a hydrogen peroxide/peroxyacetic acid product, and (3) 3000 ppm sodium hypochlorite with pH unadjusted (pH of approximately 10.0). A fourth treatment, 6000 ppm sodium hypochlorite solution with pH adjusted to 7.0, was included only for Method 966.04 as a positive control (high level of efficacy). The contact time was 10 min for all chemical treatments except the 6000 ppm sodium hypochlorite treatment which was tested at 30 min. Each chemical treatment was tested 3 times using each of the methods. Only 2 of the laboratories performed the AOAC method. Method performance was assessed by the within-laboratory variance, between-laboratory variance, and total variance associated with the log reduction (LR) estimates generated by each quantitative method. The quantitative methods performed similarly, and the LR values generated by each method were not statistically different for the 3 treatments evaluated. Based on feedback from the participating laboratories, compared to the TSM, ASTM E 2111-00 was more resource demanding and required more set-up time. The logistical and resource concerns identified

  5. Standardized protocols for quality control of MRM-based plasma proteomic workflows.

    PubMed

    Percy, Andrew J; Chambers, Andrew G; Smith, Derek S; Borchers, Christoph H

    2013-01-04

    Mass spectrometry (MS)-based proteomics is rapidly emerging as a viable technology for the identification and quantitation of biological samples, such as human plasma--the most complex yet commonly employed biofluid in clinical analyses. The transition from a qualitative to quantitative science is required if proteomics is going to successfully make the transition to a clinically useful technique. MS, however, has been criticized for a lack of reproducibility and interlaboratory transferability. Currently, the MS and plasma proteomics communities lack standardized protocols and reagents to ensure that high-quality quantitative data can be accurately and precisely reproduced by laboratories across the world using different MS technologies. Toward addressing this issue, we have developed standard protocols for multiple reaction monitoring (MRM)-based assays with customized isotopically labeled internal standards for quality control of the sample preparation workflow and the MS platform in quantitative plasma proteomic analyses. The development of reference standards and their application to a single MS platform is discussed herein, along with the results from intralaboratory tests. The tests highlighted the importance of the reference standards in assessing the efficiency and reproducibility of the entire bottom-up proteomic workflow and revealed errors related to the sample preparation and performance quality and deficits of the MS and LC systems. Such evaluations are necessary if MRM-based quantitative plasma proteomics is to be used in verifying and validating putative disease biomarkers across different research laboratories and eventually in clinical laboratories.

  6. Distributional assumptions in food and feed commodities- development of fit-for-purpose sampling protocols.

    PubMed

    Paoletti, Claudia; Esbensen, Kim H

    2015-01-01

    Material heterogeneity influences the effectiveness of sampling procedures. Most sampling guidelines used for assessment of food and/or feed commodities are based on classical statistical distribution requirements, the normal, binomial, and Poisson distributions-and almost universally rely on the assumption of randomness. However, this is unrealistic. The scientific food and feed community recognizes a strong preponderance of non random distribution within commodity lots, which should be a more realistic prerequisite for definition of effective sampling protocols. Nevertheless, these heterogeneity issues are overlooked as the prime focus is often placed only on financial, time, equipment, and personnel constraints instead of mandating acquisition of documented representative samples under realistic heterogeneity conditions. This study shows how the principles promulgated in the Theory of Sampling (TOS) and practically tested over 60 years provide an effective framework for dealing with the complete set of adverse aspects of both compositional and distributional heterogeneity (material sampling errors), as well as with the errors incurred by the sampling process itself. The results of an empirical European Union study on genetically modified soybean heterogeneity, Kernel Lot Distribution Assessment are summarized, as they have a strong bearing on the issue of proper sampling protocol development. TOS principles apply universally in the food and feed realm and must therefore be considered the only basis for development of valid sampling protocols free from distributional constraints.

  7. Study protocol: quantitative fibronectin to help decision-making in women with symptoms of preterm labour (QUIDS) part 2, UK Prospective Cohort Study

    PubMed Central

    Wotherspoon, Lisa M; Boyd, Kathleen Anne; Morris, Rachel K; Jackson, Lesley; Chandiramani, Manju; David, Anna L; Khalil, Asma; Shennan, Andrew; Hodgetts Morton, Victoria; Lavender, Tina; Khan, Khalid; Harper-Clarke, Susan; Mol, Ben; Riley, Richard D; Norrie, John; Norman, Jane

    2018-01-01

    Introduction The aim of the QUIDS study is to develop a decision support tool for the management of women with symptoms and signs of preterm labour, based on a validated prognostic model using quantitative fetal fibronectin (fFN) concentration, in combination with clinical risk factors. Methods and analysis The study will evaluate the Rapid fFN 10Q System (Hologic, Marlborough, Massachusetts, USA) which quantifies fFN in a vaginal swab. In QUIDS part 2, we will perform a prospective cohort study in at least eight UK consultant-led maternity units, in women with symptoms of preterm labour at 22+0 to 34+6 weeks gestation to externally validate a prognostic model developed in QUIDS part 1. The effects of quantitative fFN on anxiety will be assessed, and acceptability of the test and prognostic model will be evaluated in a subgroup of women and clinicians (n=30). The sample size is 1600 women (with estimated 96–192 events of preterm delivery within 7 days of testing). Clinicians will be informed of the qualitative fFN result (positive/negative) but be blinded to quantitative fFN result. Research midwives will collect outcome data from the maternal and neonatal clinical records. The final validated prognostic model will be presented as a mobile or web-based application. Ethics and dissemination The study is funded by the National Institute of Healthcare Research Health Technology Assessment (HTA 14/32/01). It has been approved by the West of Scotland Research Ethics Committee (16/WS/0068). Version Protocol V.2, Date 1 November 2016. Trial registration number ISRCTN41598423 and CPMS: 31277. PMID:29674373

  8. Predicting Performance on a Firefighter's Ability Test from Fitness Parameters

    ERIC Educational Resources Information Center

    Michaelides, Marcos A.; Parpa, Koulla M.; Thompson, Jerald; Brown, Barry

    2008-01-01

    The purpose of this project was to identify the relationships between various fitness parameters such as upper body muscular endurance, upper and lower body strength, flexibility, body composition and performance on an ability test (AT) that included simulated firefighting tasks. A second intent was to create a regression model that would predict…

  9. A combined static-dynamic single-dose imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT.

    PubMed

    Sciammarella, Maria; Shrestha, Uttam M; Seo, Youngho; Gullberg, Grant T; Botvinick, Elias H

    2017-08-03

    SPECT myocardial perfusion imaging (MPI) is a clinical mainstay that is typically performed with static imaging protocols and visually or semi-quantitatively assessed for perfusion defects based upon the relative intensity of myocardial regions. Dynamic cardiac SPECT presents a new imaging technique based on time-varying information of radiotracer distribution, which permits the evaluation of regional myocardial blood flow (MBF) and coronary flow reserve (CFR). In this work, a preliminary feasibility study was conducted in a small patient sample designed to implement a unique combined static-dynamic single-dose one-day visit imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT for improving the diagnosis of coronary artery disease (CAD). Fifteen patients (11 males, four females, mean age 71 ± 9 years) were enrolled for a combined dynamic and static SPECT (Infinia Hawkeye 4, GE Healthcare) imaging protocol with a single dose of 99m Tc-tetrofosmin administered at rest and a single dose administered at stress in a one-day visit. Out of 15 patients, eleven had selective coronary angiography (SCA), 8 within 6 months and the rest within 24 months of SPECT imaging, without intervening symptoms or interventions. The extent and severity of perfusion defects in each myocardial region was graded visually. Dynamically acquired data were also used to estimate the MBF and CFR. Both visually graded images and estimated CFR were tested against SCA as a reference to evaluate the validity of the methods. Overall, conventional static SPECT was normal in ten patients and abnormal in five patients, dynamic SPECT was normal in 12 patients and abnormal in three patients, and CFR from dynamic SPECT was normal in nine patients and abnormal in six patients. Among those 11 patients with SCA, conventional SPECT was normal in 5, 3 with documented CAD on SCA with an overall accuracy of 64%, sensitivity of 40% and specificity of 83%. Dynamic SPECT image

  10. Validation of Test Weighing Protocol to Estimate Enteral Feeding Volumes in Preterm Infants.

    PubMed

    Rankin, Michael W; Jimenez, Elizabeth Yakes; Caraco, Marina; Collinson, Marie; Lostetter, Lisa; DuPont, Tara L

    2016-11-01

    To evaluate the accuracy of pre- and postfeeding weights to estimate enteral feeding volumes in preterm infants. Single-center prospective cohort study of infants 28-36 weeks' corrected age receiving gavage feedings. For each test weight, 3 pre- and 3 postgavage feeding weights were obtained by study personnel, blinded to feeding volume, via a specific protocol. The correlation between test weight difference and actual volume ingested was assessed by the use of summary statistics, Spearman rho, and graphical analyses. The relationship between categorical predictive variables and a predefined acceptable difference (±5 mL) was assessed with the χ 2 or Fisher exact test. A total of 101 test weights were performed in 68 infants. Estimated and actual feeding volumes were highly correlated (r = 0.94, P < .001), with a mean absolute difference of 2.95 mL (SD: 2.70; range: 0, 12.3 mL; 5th, 95th percentile: 0, 9.3); 85% of test weights were within ±5 mL of actual feeding volume and did not vary significantly by corrected age, feeding tube or respiratory support type, feeding duration or volume, formula vs breast milk, or caloric density. With adherence to study protocol, 89% of test weights (66/74) were within ±5 mL of actual volume, compared with 71% (19/27, P = .04) when concerns about protocol adherence were noted (eg, difficulty securing oxygen tubing). Via the use of a standard protocol, feeding volumes can be estimated accurately by pre- and postfeeding weights. Test weighing could be a valuable tool to support direct breastfeeding in the neonatal intensive care unit. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. A real-time, quantitative PCR protocol for assessing the relative parasitemia of Leucocytozoon in waterfowl

    USGS Publications Warehouse

    Smith, Matthew M.; Schmutz, Joel A.; Apelgren, Chloe; Ramey, Andy M.

    2015-01-01

    Microscopic examination of blood smears can be effective at diagnosing and quantifying hematozoa infections. However, this method requires highly trained observers, is time consuming, and may be inaccurate for detection of infections at low levels of parasitemia. To develop a molecular methodology for identifying and quantifying Leucocytozoon parasite infection in wild waterfowl (Anseriformes), we designed a real-time, quantitative PCR protocol to amplify Leucocytozoon mitochondrial DNA using TaqMan fluorogenic probes and validated our methodology using blood samples collected from waterfowl in interior Alaska during late summer and autumn (n = 105). By comparing our qPCR results to those derived from a widely used nested PCR protocol, we determined that our assay showed high levels of sensitivity (91%) and specificity (100%) in detecting Leucocytozoon DNA from host blood samples. Additionally, results of a linear regression revealed significant correlation between the raw measure of parasitemia produced by our qPCR assay (Ct values) and numbers of parasites observed on blood smears (R2 = 0.694, P = 0.003), indicating that our assay can reliably determine the relative parasitemia levels among samples. This methodology provides a powerful new tool for studies assessing effects of haemosporidian infection in wild avian species.

  12. It's Time to Develop a New "Draft Test Protocol" for a Mars Sample Return Mission (or Two…).

    PubMed

    Rummel, John D; Kminek, Gerhard

    2018-04-01

    The last time NASA envisioned a sample return mission from Mars, the development of a protocol to support the analysis of the samples in a containment facility resulted in a "Draft Test Protocol" that outlined required preparations "for the safe receiving, handling, testing, distributing, and archiving of martian materials here on Earth" (Rummel et al., 2002 ). This document comprised a specific protocol to be used to conduct a biohazard test for a returned martian sample, following the recommendations of the Space Studies Board of the US National Academy of Sciences. Given the planned launch of a sample-collecting and sample-caching rover (Mars 2020) in 2 years' time, and with a sample return planned for the end of the next decade, it is time to revisit the Draft Test Protocol to develop a sample analysis and biohazard test plan to meet the needs of these future missions. Key Words: Biohazard detection-Mars sample analysis-Sample receiving facility-Protocol-New analytical techniques-Robotic sample handling. Astrobiology 18, 377-380.

  13. Effect of fit testing on the protection offered by n95 filtering facepiece respirators against fine particles in a laboratory setting.

    PubMed

    Reponen, Tiina; Lee, Shu-An; Grinshpun, Sergey A; Johnson, Erik; McKay, Roy

    2011-04-01

    This study investigated particle-size-selective protection factors (PFs) of four models of N95 filtering facepiece respirators (FFRs) that passed and failed fit testing. Particle size ranges were representative of individual viruses and bacteria (aerodynamic diameter d(a) = 0.04-1.3 μm). Standard respirator fit testing was followed by particle-size-selective measurement of PFs while subjects wore N95 FFRs in a test chamber. PF values obtained for all subjects were then compared to those obtained for the subjects who passed the fit testing. Overall fit test passing rate for all four models of FFRs was 67%. Of these, 29% had PFs <10 (the Occupational Safety and Health Administration Assigned Protection Factor designated for this type of respirator). When only subjects that passed fit testing were included, PFs improved with 9% having values <10. On average, the PFs were 1.4 times (29.5/21.5) higher when only data for those who passed fit testing were included. The minimum PFs were consistently observed in the particle size range of 0.08-0.2 μm. Overall PFs increased when subjects passed fit testing. The results support the value of fit testing but also show for the first time that PFs are dependent on particle size regardless of fit testing status.

  14. Cardiorespiratory and cardiac autonomic responses to 30-15 intermittent fitness test in team sport players.

    PubMed

    Buchheit, Martin; Al Haddad, Hani; Millet, Grégoire Paul; Lepretre, Pierre Marie; Newton, Michael; Ahmaidi, Said

    2009-01-01

    The 30-15 Intermittent Fitness Test (30-15IFT) is an attractive alternative to classic continuous incremental field tests for defining a reference velocity for interval training prescription in team sport athletes. The aim of the present study was to compare cardiorespiratory and autonomic responses to 30-15IFT with those observed during a standard continuous test (CT). In 20 team sport players (20.9 +/- 2.2 years), cardiopulmonary parameters were measured during exercise and for 10 minutes after both tests. Final running velocity, peak lactate ([La]peak), and rating of perceived exertion (RPE) were also measured. Parasympathetic function was assessed during the postexercise recovery phase via heart rate (HR) recovery time constant (HRR[tau]) and HR variability (HRV) vagal-related indices. At exhaustion, no difference was observed in peak oxygen uptake VO2peak), respiratory exchange ratio, HR, or RPE between 30-15IFT and CT. In contrast, 30-15IFT led to significantly higher minute ventilation, [La]peak, and final velocity than CT (p < 0.05 for all parameters). All maximal cardiorespiratory variables observed during both tests were moderately to well correlated (e.g., r = 0.76, p = 0.001 for [latin capital VO2peak). Regarding ventilatory thresholds (VThs), all cardiorespiratory measurements were similar and well correlated between the 2 tests. Parasympathetic function was lower after 30-15IFT than after CT, as indicated by significantly longer HHR[tau] (81.9 +/- 18.2 vs. 60.5 +/- 19.5 for 30-15IFT and CT, respectively, p < 0.001) and lower HRV vagal-related indices (i.e., the root mean square of successive R-R intervals differences [rMSSD]: 4.1 +/- 2.4 and 7.0 +/- 4.9 milliseconds, p < 0.05). In conclusion, the 30-15IFT is accurate for assessing VThs and VO2peak, but it alters postexercise parasympathetic function more than a continuous incremental protocol.

  15. Testing warning messages on smokers' cigarette packages: a standardised protocol.

    PubMed

    Brewer, Noel T; Hall, Marissa G; Lee, Joseph G L; Peebles, Kathryn; Noar, Seth M; Ribisl, Kurt M

    2016-03-01

    Lab experiments on cigarette warnings typically use a brief one-time exposure that is not paired with the cigarette packs smokers use every day, leaving open the question of how repeated warning exposure over several weeks may affect smokers. This proof of principle study sought to develop a new protocol for testing cigarette warnings that better reflects real-world exposure by presenting them on cigarette smokers' own packs. We tested a cigarette pack labelling protocol with 76 US smokers ages 18 and older. We applied graphic warnings to the front and back of smokers' cigarette packs. Most smokers reported that at least 75% of the packs of cigarettes they smoked during the study had our warnings. Nearly all said they would participate in the study again. Using cigarette packs with the study warnings increased quit intentions (p<0.05). Our findings suggest a feasible pack labelling protocol with six steps: (1) schedule appointments at brief intervals; (2) determine typical cigarette consumption; (3) ask smokers to bring a supply of cigarette packs to study appointments; (4) apply labels to smokers' cigarette packs; (5) provide participation incentives at the end of appointments; and (6) refer smokers to cessation services at end of the study. When used in randomised controlled trials in settings with real-world message exposure over time, this protocol may help identify the true impact of warnings and thus better inform tobacco product labelling policy. NCT02247908. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  16. Warm-ups for military fitness testing: rapid evidence assessment of the literature.

    PubMed

    Zeno, Stacey A; Purvis, Dianna; Crawford, Cindy; Lee, Courtney; Lisman, Peter; Deuster, Patricia A

    2013-07-01

    Warm-up exercises are commonly used before exercise as a method to physiologically prepare for strenuous physical activity. Various warm-up exercises are often implemented but without scientific merit and, at times, may be detrimental to performance. To date, no systematic reviews have examined the effectiveness of warm-up exercises for military physical fitness test (PFT) or combat fitness test (CFT). The purpose of this rapid evidence assessment of the literature was to examine the quantity, quality, and effectiveness of warm-up exercises for PFT and identify those that might increase PFT and/or CFT scores, as reported in the literature. Literature searches of randomized controlled trials were performed across various databases from database inception to May 2011. Methodological quality of included studies was assessed using the Scottish Intercollegiate Guidelines Network (SIGN) 50 criteria for randomized controlled trial designs, and studies were individually described. Subject matter experts summarized the results applicable or generalizable to military testing. The search yielded a total of 1177 citations, with 37 fitting our inclusion criteria. Cardiovascular warm-ups increased sprint/running time, but dynamic stretching and dynamic warm-ups had the most positive outcome for the various exercise tests examined. Systematically, static stretching had no beneficial or detrimental effect on exercise performance but did improve range of movement exercises. Selected warm-up exercise may increase PFT and possibly CFT scores. Further research is needed to investigate the efficacy of dynamic stretching and dynamic warm-ups.

  17. Modified Distribution-Free Goodness-of-Fit Test Statistic.

    PubMed

    Chun, So Yeon; Browne, Michael W; Shapiro, Alexander

    2018-03-01

    Covariance structure analysis and its structural equation modeling extensions have become one of the most widely used methodologies in social sciences such as psychology, education, and economics. An important issue in such analysis is to assess the goodness of fit of a model under analysis. One of the most popular test statistics used in covariance structure analysis is the asymptotically distribution-free (ADF) test statistic introduced by Browne (Br J Math Stat Psychol 37:62-83, 1984). The ADF statistic can be used to test models without any specific distribution assumption (e.g., multivariate normal distribution) of the observed data. Despite its advantage, it has been shown in various empirical studies that unless sample sizes are extremely large, this ADF statistic could perform very poorly in practice. In this paper, we provide a theoretical explanation for this phenomenon and further propose a modified test statistic that improves the performance in samples of realistic size. The proposed statistic deals with the possible ill-conditioning of the involved large-scale covariance matrices.

  18. EVA Human Health and Performance Benchmarking Study Overview and Development of a Microgravity Protocol

    NASA Technical Reports Server (NTRS)

    Norcross, Jason; Jarvis, Sarah; Bekdash, Omar; Cupples, Scott; Abercromby, Andrew

    2017-01-01

    The primary objective of this study is to develop a protocol to reliably characterize human health and performance metrics for individuals working inside various EVA suits under realistic spaceflight conditions. Expected results and methodologies developed during this study will provide the baseline benchmarking data and protocols with which future EVA suits and suit configurations (e.g., varied pressure, mass, center of gravity [CG]) and different test subject populations (e.g., deconditioned crewmembers) may be reliably assessed and compared. Results may also be used, in conjunction with subsequent testing, to inform fitness-for-duty standards, as well as design requirements and operations concepts for future EVA suits and other exploration systems.

  19. The Responsible Use of Youth Fitness Testing to Enhance Student Motivation, Enjoyment, and Performance

    ERIC Educational Resources Information Center

    Wiersma, Lenny D.; Sherman, Clay P.

    2008-01-01

    While physical fitness testing has the potential to invoke embarrassment and anxiety, strategies can be developed that can motivate students to exert maximal effort, provide positive feedback on skill improvement, and encourage students to set fitness goals that can be achieved through developmentally appropriate physical activities. The purpose…

  20. The Helmet Fit Index--An intelligent tool for fit assessment and design customisation.

    PubMed

    Ellena, Thierry; Subic, Aleksandar; Mustafa, Helmy; Pang, Toh Yen

    2016-07-01

    Helmet safety benefits are reduced if the headgear is poorly fitted on the wearer's head. At present, there are no industry standards available to assess objectively how a specific protective helmet fits a particular person. A proper fit is typically defined as a small and uniform distance between the helmet liner and the wearer's head shape, with a broad coverage of the head area. This paper presents a novel method to investigate and compare fitting accuracy of helmets based on 3D anthropometry, reverse engineering techniques and computational analysis. The Helmet Fit Index (HFI) that provides a fit score on a scale from 0 (excessively poor fit) to 100 (perfect fit) was compared with subjective fit assessments of surveyed cyclists. Results in this study showed that quantitative (HFI) and qualitative (participants' feelings) data were related when comparing three commercially available bicycle helmets. Findings also demonstrated that females and Asian people have lower fit scores than males and Caucasians, respectively. The HFI could provide detailed understanding of helmet efficiency regarding fit and could be used during helmet design and development phases. Copyright © 2016 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  1. Youth fitness testing: the effect of percentile-based evaluative feedback on intrinsic motivation.

    PubMed

    Whitehead, J R; Corbin, C B

    1991-06-01

    This study was a test of Deci and Ryan's (1985) cognitive evaluation theory in a fitness testing situation. More specifically, it was a test of Proposition 2 of that theory, which posits that external events that increase or decrease perceived competence will increase or decrease intrinsic motivation. Seventh and eighth grade schoolchildren (N = 105) volunteered for an experiment that was ostensibly to collect data on a new youth fitness test (the Illinois Agility Run). After two untimed practice runs, a specially adapted version of the Intrinsic Motivation Inventory (IMI) was administered as a pretest of intrinsic motivation. Two weeks later when subjects ran again, they were apparently electronically timed. In reality, the subjects were given bogus feedback. Subjects in a positive feedback condition were told their scores were above the 80th percentile, while those in a negative feedback condition were told their scores were below the 20th percentile. Those in a control condition received no feedback. The IMI was again administered to the subjects after their runs. Multivariate and subsequent univariate tests were significant for all four subscale dependent variables (perceived interest-enjoyment, competence, effort, and pressure-tension). Positive feedback enhanced all aspects of intrinsic motivation, whereas negative feedback decreased them. In a further test of cognitive evaluation theory, path analysis results supported the prediction that perceived competence would mediate changes in the other IMI subscales. Taken together, these results clearly support cognitive evaluation theory and also may have important implications regarding motivation for those who administer youth fitness tests.

  2. Simulated linear test applied to quantitative proteomics.

    PubMed

    Pham, T V; Jimenez, C R

    2016-09-01

    Omics studies aim to find significant changes due to biological or functional perturbation. However, gene and protein expression profiling experiments contain inherent technical variation. In discovery proteomics studies where the number of samples is typically small, technical variation plays an important role because it contributes considerably to the observed variation. Previous methods place both technical and biological variations in tightly integrated mathematical models that are difficult to adapt for different technological platforms. Our aim is to derive a statistical framework that allows the inclusion of a wide range of technical variability. We introduce a new method called the simulated linear test, or the s-test, that is easy to implement and easy to adapt for different models of technical variation. It generates virtual data points from the observed values according to a pre-defined technical distribution and subsequently employs linear modeling for significance analysis. We demonstrate the flexibility of the proposed approach by deriving a new significance test for quantitative discovery proteomics for which missing values have been a major issue for traditional methods such as the t-test. We evaluate the result on two label-free (phospho) proteomics datasets based on ion-intensity quantitation. Available at http://www.oncoproteomics.nl/software/stest.html : t.pham@vumc.nl. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  3. Health-related physical fitness assessment in a community-based cancer rehabilitation setting.

    PubMed

    Kirkham, Amy A; Neil-Sztramko, Sarah E; Morgan, Joanne; Hodson, Sara; Weller, Sarah; McRae, Tasha; Campbell, Kristin L

    2015-09-01

    Assessment of physical fitness is important in order to set goals, appropriately prescribe exercise, and monitor change over time. This study aimed to determine the utility of a standardized physical fitness assessment for use in cancer-specific, community-based exercise programs. Tests anticipated to be feasible and suitable for a community setting and a wide range of ages and physical function were chosen to measure body composition, aerobic fitness, strength, flexibility, and balance. Cancer Exercise Trainers/Specialists at cancer-specific, community-based exercise programs assessed new clients (n = 60) at enrollment, designed individualized exercise programs, and then performed a re-assessment 3-6 months later (n = 34). Resting heart rate, blood pressure, body mass index, waist circumference, handgrip strength, chair stands, sit-and-reach, back scratch, single-leg standing, and timed up-and-go tests were considered suitable and feasible tests/measures, as they were performed in most (≥88 %) participants. The ability to capture change was also noted for resting blood pressure (-7/-5 mmHg, p = 0.02), chair stands (+4, p < 0.01), handgrip strength (+2 kg, p < 0.01), and sit-and-reach (+3 cm, p = 0.03). While the submaximal treadmill test captured a meaningful improvement in aerobic fitness (+62 s, p = 0.17), it was not completed in 33 % of participants. Change in mobility, using the timed up-and-go was nominal and was not performed in 27 %. Submaximal treadmill testing, handgrip dynamometry, chair stands, and sit-and-reach tests were feasible, suitable, and provided meaningful physical fitness information in a cancer-specific, community-based, exercise program setting. However, a shorter treadmill protocol and more sensitive balance and upper body flexibility tests should be investigated.

  4. Prior-knowledge Fitting of Accelerated Five-dimensional Echo Planar J-resolved Spectroscopic Imaging: Effect of Nonlinear Reconstruction on Quantitation.

    PubMed

    Iqbal, Zohaib; Wilson, Neil E; Thomas, M Albert

    2017-07-24

    1 H Magnetic Resonance Spectroscopic imaging (SI) is a powerful tool capable of investigating metabolism in vivo from mul- tiple regions. However, SI techniques are time consuming, and are therefore difficult to implement clinically. By applying non-uniform sampling (NUS) and compressed sensing (CS) reconstruction, it is possible to accelerate these scans while re- taining key spectral information. One recently developed method that utilizes this type of acceleration is the five-dimensional echo planar J-resolved spectroscopic imaging (5D EP-JRESI) sequence, which is capable of obtaining two-dimensional (2D) spectra from three spatial dimensions. The prior-knowledge fitting (ProFit) algorithm is typically used to quantify 2D spectra in vivo, however the effects of NUS and CS reconstruction on the quantitation results are unknown. This study utilized a simulated brain phantom to investigate the errors introduced through the acceleration methods. Errors (normalized root mean square error >15%) were found between metabolite concentrations after twelve-fold acceleration for several low concentra- tion (<2 mM) metabolites. The Cramér Rao lower bound% (CRLB%) values, which are typically used for quality control, were not reflective of the increased quantitation error arising from acceleration. Finally, occipital white (OWM) and gray (OGM) human brain matter were quantified in vivo using the 5D EP-JRESI sequence with eight-fold acceleration.

  5. Optimization of Fit for Mass Customized Apparel Ordering Using Fit Preference and Self Measurement.

    DTIC Science & Technology

    2000-01-01

    shorts had the highest satisfaction of fit and which short provided the optimum fit. Finally a discrepancy question form and a manual order form were...used during fit test sessions. In pilot testing manual order forms were used exclusively to record self-measurements and fit preference responses for...test participants. The website requirements were completed on site in the pilot test and manual order forms were returned to test evaluators once

  6. Metrologies for quantitative nanomechanical testing and quality control in semiconductor manufacturing

    NASA Astrophysics Data System (ADS)

    Pratt, Jon R.; Kramar, John A.; Newell, David B.; Smith, Douglas T.

    2005-05-01

    If nanomechanical testing is to evolve into a tool for process and quality control in semiconductor fabrication, great advances in throughput, repeatability, and accuracy of the associated instruments and measurements will be required. A recent grant awarded by the NIST Advanced Technology Program seeks to address the throughput issue by developing a high-speed AFM-based platform for quantitative nanomechanical measurements. The following paper speaks to the issue of quantitative accuracy by presenting an overview of various standards and techniques under development at NIST and other national metrology institutes (NMIs) that can provide a metrological basis for nanomechanical testing. The infrastructure we describe places firm emphasis on traceability to the International System of Units, paving the way for truly quantitative, rather than qualitative, physical property testing.

  7. Internal fit of single crowns produced by CAD-CAM and lost-wax metal casting technique assessed by the triple-scan protocol.

    PubMed

    Dahl, Bjørn Einar; Rønold, Hans Jacob; Dahl, Jon E

    2017-03-01

    Whether single crowns produced by computer-aided design and computer-aided manufacturing (CAD-CAM) have an internal fit comparable to crowns made by lost-wax metal casting technique is unknown. The purpose of this in vitro study was to compare the internal fit of single crowns produced with the lost-wax and metal casting technique with that of single crowns produced with the CAD-CAM technique. The internal fit of 5 groups of single crowns produced with the CAD-CAM technique was compared with that of single crowns produced in cobalt-chromium with the conventional lost-wax and metal casting technique. Comparison was performed using the triple-scan protocol; scans of the master model, the crown on the master model, and the intaglio of the crown were superimposed and analyzed with computer software. The 5 groups were milled presintered zirconia, milled hot isostatic pressed zirconia, milled lithium disilicate, milled cobalt-chromium, and laser-sintered cobalt-chromium. The cement space in both the mesiodistal and buccopalatal directions was statistically smaller (P<.05) for crowns made by the conventional lost-wax and metal casting technique compared with that of crowns produced by the CAD-CAM technique. Single crowns made using the conventional lost-wax and metal casting technique have better internal fit than crowns produced using the CAD-CAM technique. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. Fitness testing of tennis players: How valuable is it?

    PubMed Central

    Fernandez-Fernandez, Jaime; Ulbricht, Alexander; Ferrauti, Alexander

    2014-01-01

    In tennis, sport-specific technical skills are predominant factors, although a complex profile of physical performance factors is also required. The fitness test batteries assist in examining tennis players’ capabilities for performance at different levels in the laboratory as well as in the field, in the junior or elite level. While laboratory tests can be, and are, used to evaluate basic performance characteristics of athletes in most individual sports, in a more specific approach, field-based methods are better suited to the demands of complex intermittent sports like tennis. A regular test battery performed at different periods of the year allows to obtain an individual's performance profile, as well as the ability to prescribe individual training interventions. Thus, the aim of the present review was to describe and evaluate the different physical tests recommended and used by practitioners, sports scientists and institutions (national tennis federations). PMID:24668375

  9. Testing for biases in selection on avian reproductive traits and partitioning direct and indirect selection using quantitative genetic models.

    PubMed

    Reed, Thomas E; Gienapp, Phillip; Visser, Marcel E

    2016-10-01

    Key life history traits such as breeding time and clutch size are frequently both heritable and under directional selection, yet many studies fail to document microevolutionary responses. One general explanation is that selection estimates are biased by the omission of correlated traits that have causal effects on fitness, but few valid tests of this exist. Here, we show, using a quantitative genetic framework and six decades of life-history data on two free-living populations of great tits Parus major, that selection estimates for egg-laying date and clutch size are relatively unbiased. Predicted responses to selection based on the Robertson-Price Identity were similar to those based on the multivariate breeder's equation (MVBE), indicating that unmeasured covarying traits were not missing from the analysis. Changing patterns of phenotypic selection on these traits (for laying date, linked to climate change) therefore reflect changing selection on breeding values, and genetic constraints appear not to limit their independent evolution. Quantitative genetic analysis of correlational data from pedigreed populations can be a valuable complement to experimental approaches to help identify whether apparent associations between traits and fitness are biased by missing traits, and to parse the roles of direct versus indirect selection across a range of environments. © 2016 The Author(s). Evolution © 2016 The Society for the Study of Evolution.

  10. A policy-driven multifaceted approach for early childhood physical fitness promotion: impacts on body composition and physical fitness in young Chinese children

    PubMed Central

    2014-01-01

    Background The prevalence of obesity increased while certain measures of physical fitness deteriorated in preschool children in China over the past decade. This study tested the effectiveness of a multifaceted intervention that integrated childcare center, families, and community to promote healthy growth and physical fitness in preschool Chinese children. Methods This 12-month study was conducted using a quasi-experimental pretest/posttest design with comparison group. The participants were 357 children (mean age = 4.5 year) enrolled in three grade levels in two childcare centers in Beijing, China. The intervention included: 1) childcare center intervention (physical activity policy changes, teacher training, physical education curriculum and food services training), 2) family intervention (parent education, internet website for support, and family events), and 3) community intervention (playground renovation and community health promotion events). The study outcome measures included body composition (percent body fat, fat mass, and muscle mass), Body Mass Index (BMI) and BMI z-score and physical fitness scores in 20-meter agility run (20M-AR), broad jump for distance (BJ), timed 10-jumps, tennis ball throwing (TBT), sit and reach (SR), balance beam walk (BBW), 20-meter crawl (20M-C)), 30-meter sprint (30M-S)) from a norm referenced test. Measures of process evaluation included monitoring of children’s physical activity (activity time and intensity) and food preparation records, and fidelity of intervention protocol implementation. Results Children in the intervention center significantly lowered their body fat percent (−1.2%, p < 0.0001), fat mass (−0.55 kg, p <0.0001), and body weight (0.36 kg, p <0.02) and increased muscle mass (0.48 kg, p <0.0001), compared to children in the control center. They also improved all measures of physical fitness except timed 10-jumps (20M-AR: −0.74 seconds, p < 0.0001; BJ: 8.09 cm, p < 0.0001; TBT: 0

  11. Sinusoidal voltage protocols for rapid characterisation of ion channel kinetics.

    PubMed

    Beattie, Kylie A; Hill, Adam P; Bardenet, Rémi; Cui, Yi; Vandenberg, Jamie I; Gavaghan, David J; de Boer, Teun P; Mirams, Gary R

    2018-03-24

    Ion current kinetics are commonly represented by current-voltage relationships, time constant-voltage relationships and subsequently mathematical models fitted to these. These experiments take substantial time, which means they are rarely performed in the same cell. Rather than traditional square-wave voltage clamps, we fitted a model to the current evoked by a novel sum-of-sinusoids voltage clamp that was only 8 s long. Short protocols that can be performed multiple times within a single cell will offer many new opportunities to measure how ion current kinetics are affected by changing conditions. The new model predicts the current under traditional square-wave protocols well, with better predictions of underlying currents than literature models. The current under a novel physiologically relevant series of action potential clamps is predicted extremely well. The short sinusoidal protocols allow a model to be fully fitted to individual cells, allowing us to examine cell-cell variability in current kinetics for the first time. Understanding the roles of ion currents is crucial to predict the action of pharmaceuticals and mutations in different scenarios, and thereby to guide clinical interventions in the heart, brain and other electrophysiological systems. Our ability to predict how ion currents contribute to cellular electrophysiology is in turn critically dependent on our characterisation of ion channel kinetics - the voltage-dependent rates of transition between open, closed and inactivated channel states. We present a new method for rapidly exploring and characterising ion channel kinetics, applying it to the hERG potassium channel as an example, with the aim of generating a quantitatively predictive representation of the ion current. We fitted a mathematical model to currents evoked by a novel 8 second sinusoidal voltage clamp in CHO cells overexpressing hERG1a. The model was then used to predict over 5 minutes of recordings in the same cell in response to

  12. Prediction of Fitness to Drive in Patients with Alzheimer's Dementia

    PubMed Central

    Piersma, Dafne; Fuermaier, Anselm B. M.; de Waard, Dick; Davidse, Ragnhild J.; de Groot, Jolieke; Doumen, Michelle J. A.; Bredewoud, Ruud A.; Claesen, René; Lemstra, Afina W.; Vermeeren, Annemiek; Ponds, Rudolf; Verhey, Frans; Brouwer, Wiebo H.; Tucha, Oliver

    2016-01-01

    The number of patients with Alzheimer’s disease (AD) is increasing and so is the number of patients driving a car. To enable patients to retain their mobility while at the same time not endangering public safety, each patient should be assessed for fitness to drive. The aim of this study is to develop a method to assess fitness to drive in a clinical setting, using three types of assessments, i.e. clinical interviews, neuropsychological assessment and driving simulator rides. The goals are (1) to determine for each type of assessment which combination of measures is most predictive for on-road driving performance, (2) to compare the predictive value of clinical interviews, neuropsychological assessment and driving simulator evaluation and (3) to determine which combination of these assessments provides the best prediction of fitness to drive. Eighty-one patients with AD and 45 healthy individuals participated. All participated in a clinical interview, and were administered a neuropsychological test battery and a driving simulator ride (predictors). The criterion fitness to drive was determined in an on-road driving assessment by experts of the CBR Dutch driving test organisation according to their official protocol. The validity of the predictors to determine fitness to drive was explored by means of logistic regression analyses, discriminant function analyses, as well as receiver operating curve analyses. We found that all three types of assessments are predictive of on-road driving performance. Neuropsychological assessment had the highest classification accuracy followed by driving simulator rides and clinical interviews. However, combining all three types of assessments yielded the best prediction for fitness to drive in patients with AD with an overall accuracy of 92.7%, which makes this method highly valid for assessing fitness to drive in AD. This method may be used to advise patients with AD and their family members about fitness to drive. PMID:26910535

  13. Proposed test protocol for video imaging detection at intersection stop lines.

    DOT National Transportation Integrated Search

    2010-08-01

    Test protocols for non-loop detectors have often required comparing the performance : attributes of these detectors with those of loops or other point detectors, or to manual counts. : However, that comparison is not always appropriate for a variety ...

  14. Firefighter exercise protocols conducted in an environmental chamber: developing a laboratory-based simulated firefighting protocol.

    PubMed

    Ensari, Ipek; Motl, Robert W; Klaren, Rachel E; Fernhall, Bo; Smith, Denise L; Horn, Gavin P

    2017-05-01

    A standard exercise protocol that allows comparisons across various ergonomic studies would be of great value for researchers investigating the physical and physiological strains of firefighting and possible interventions for reducing the demands. We compared the pattern of cardiorespiratory changes from 21 firefighters during simulated firefighting activities using a newly developed firefighting activity station (FAS) and treadmill walking both performed within an identical laboratory setting. Data on cardiorespiratory parameters and core temperature were collected continuously using a portable metabolic unit and a wireless ingestible temperature probe. Repeated measures ANOVA indicated distinct patterns of change in cardiorespiratory parameters and heart rate between conditions. The pattern consisted of alternating periods of peaks and nadirs in the FAS that were qualitatively and quantitatively similar to live fire activities, whereas the same parameters increased logarithmically in the treadmill condition. Core temperature increased in a similarly for both conditions, although more rapidly in the FAS. Practitioner Summary: The firefighting activity station (FAS) yields a pattern of cardiorespiratory responses qualitatively and quantitatively similar to live fire activities, significantly different than treadmill walking. The FAS can be performed in a laboratory/clinic, providing a potentially standardised protocol for testing interventions to improve health and safety and conducting return to duty decisions.

  15. Physical fitness and future cardiovascular risk in argentine children and adolescents: an introduction to the ALPHA test battery.

    PubMed

    Secchi, Jeremías David; García, Gastón César; España-Romero, Vanesa; Castro-Piñero, José

    2014-04-01

    A high level of physical fitness is associated with cardiovascular health in children and adolescents. At present, there is no systematic implementation of a test battery to assess physical fitness at schools in Argentina. The main objective of this study was to implement the ALPHA test battery to determine the physical fitness of a sample made up of Argentine children and adolescents and to establish the proportion of subjects whose aerobic capacity is indicative of future cardiovascular risk. A sample of 1867 participants (967 girls) aged 6 to 19.5 years old assessed using the ALPHA test battery. Four components of physical fitness were measured: 1) morphological component: height, body weight, and waist circumference; 2) musculoskeletal component: standing long jump test; 3) motor component: speed/agility test (4x10 m shuttle run); 4) cardiorespiratory component: course-navette 20 m, shuttle run test and estimation of maximal oxygen consumption. The 5th, 25th, 50th, 75th, and 95th percentiles were estimated for the main tests. The mean body mass index was 20.8 kg/m2, and 7.8% of participants were classified as obese. In ddition, male participants had a better performance in all physical fitness tests when compared to girls (p< 0.001). An aerobic capacity indicative of cardiovascular risk was observed in 31.6% of all participants. Argentine male children and adolescents included in the sample showed higher levels of physical fitness. Such differences increase with age. Approximately one every three participants had an aerobic capacity indicative of future cardiovascular risk.

  16. Respirator fit of a medium mask on a group of South Africans: a cross-sectional study

    PubMed Central

    2011-01-01

    Background In South Africa, respiratory protective equipment is often the primary control method used to protect workers. This preliminary study investigated how well a common disposable P2 respirator fitted persons with a range of facial dimensions. Methods Quantitative respirator fit tests were performed on 29 volunteers from different racial, gender and face size groups. Two facial dimensions width (bizygomatic) and length (menton-sellion) were measured for all participants. Results In this study 13.8% of the participants demonstrated a successful fit with the medium sized mask. These included participants from three different racial and both gender groups. The large percentage of failed fit tests (86%) indicates that reliance on off-the-shelf respirators could be problematic in South Africa. Conclusions The limitations of this preliminary study notwithstanding, respirator fit appear to be associated with individual facial characteristics and are not specific to racial/ethnic or gender characteristics. PMID:21406106

  17. Measurement properties of the craniocervical flexion test: a systematic review protocol.

    PubMed

    Araujo, Francisco Xavier de; Ferreira, Giovanni Esteves; Scholl Schell, Maurício; Castro, Marcelo Peduzzi de; Silva, Marcelo Faria; Ribeiro, Daniel Cury

    2018-02-22

    Neck pain is the leading cause of years lived with disability worldwide and it accounts for high economic and societal burden. Altered activation of the neck muscles is a common musculoskeletal impairment presented by patients with neck pain. The craniocervical flexion test with pressure biofeedback unit has been widely used in clinical practice to assess function of deep neck flexor muscles. This systematic review will assess the measurement properties of the craniocervical flexion test for assessing deep cervical flexor muscles. This is a protocol for a systematic review that will follow the Preferred Reporting Items for Systematic Review and Meta-Analysis statement. MEDLINE (via PubMed), EMBASE, PEDro, Cochrane Central Register of Controlled Trials (CENTRAL), Scopus and Science Direct will be systematically searched from inception. Studies of any design that have investigated and reported at least one measurement property of the craniocervical flexion test for assessing the deep cervical flexor muscles will be included. All measurement properties will be considered as outcomes. Two reviewers will independently rate the risk of bias of individual studies using the updated COnsensus-based Standards for the selection of health Measurement Instruments risk of bias checklist. A structured narrative synthesis will be used for data analysis. Quantitative findings for each measurement property will be summarised. The overall rating for a measurement property will be classified as 'positive', 'indeterminate' or 'negative'. The overall rating will be accompanied with a level of evidence. Ethical approval and patient consent are not required since this is a systematic review based on published studies. Findings will be submitted to a peer-reviewed journal for publication. CRD42017062175. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. Psychometric Properties of the Quantitative Myasthenia Gravis Score and the Myasthenia Gravis Composite Scale.

    PubMed

    Barnett, Carolina; Merkies, Ingemar S J; Katzberg, Hans; Bril, Vera

    2015-09-02

    The Quantitative Myasthenia Gravis Score and the Myasthenia Gravis Composite are two commonly used outcome measures in Myasthenia Gravis. So far, their measurement properties have not been compared, so we aimed to study their psychometric properties using the Rasch model. 251 patients with stable myasthenia gravis were assessed with both scales, and 211 patients returned for a second assessment. We studied fit to the Rasch model at the first visit, and compared item fit, thresholds, differential item functioning, local dependence, person separation index, and tests for unidimensionality. We also assessed test-retest reliability and estimated the Minimal Detectable Change. Neither scale fit the Rasch model (X2p <  0.05). The Myasthenia Gravis Composite had lower discrimination properties than the Quantitative Myasthenia Gravis Scale (Person Separation Index: 0.14 and 0.7). There was local dependence in both scales, as well as differential item functioning for ocular and generalized disease. Disordered thresholds were found in 6(60%) items of the Myasthenia Gravis Composite and in 4(31%) of the Quantitative Myasthenia Gravis Score. Both tools had adequate test-retest reliability (ICCs >0.8). The minimally detectable change was 4.9 points for the Myasthenia Gravis Composite and 4.3 points for the Quantitative Myasthenia Gravis Score. Neither scale fulfilled Rasch model expectations. The Quantitative Myasthenia Gravis Score has higher discrimination than the Myasthenia Gravis Composite. Both tools have items with disordered thresholds, differential item functioning and local dependency. There was evidence of multidimensionality in the QMGS. The minimal detectable change values are higher than previous studies on the minimal significant change. These findings might inform future modifications of these tools.

  19. Wheelchair Shuttle Test for Assessing Aerobic Fitness in Youth With Spina Bifida: Validity and Reliability

    PubMed Central

    de Groot, Janke F.; Backx, Frank J.G.; Benner, Joyce; Kruitwagen, Cas L.J.J.; Takken, Tim

    2017-01-01

    Abstract Background Testing aerobic fitness in youth is important because of expected relationships with health. Objective The purpose of the study was to estimate the validity and reliability of the Shuttle Ride Test in youth who have spina bifida and use a wheelchair for mobility and sport. Design Ths study is a validity and reliability study. Methods The Shuttle Ride Test, Graded Wheelchair Propulsion Test, and skill-related fitness tests were administered to 33 participants for the validity study (age = 14.5 ± 3.1 y) and to 28 participants for the reliability study (age = 14.7 ± 3.3 y). Results No significant differences were found between the Graded Wheelchair Propulsion Test and the Shuttle Ride Test for most cardiorespiratory responses. Correlations between the Graded Wheelchair Propulsion Test and the Shuttle Ride Test were moderate to high (r = .55–.97). The variance in peak oxygen uptake (VO2peak) could be predicted for 77% of the participants by height, number of shuttles completed, and weight, with large prediction intervals. High correlations were found between number of shuttles completed and skill-related fitness tests (CI = .73 to −.92). Intraclass correlation coefficients were high (.77–.98), with a smallest detectable change of 1.5 for number of shuttles completed and with coefficients of variation of 6.2% and 6.4% for absolute VO2peak and relative VO2peak, respectively. Conclusions When measuring VO2peak directly by using a mobile gas analysis system, the Shuttle Ride Test is highly valid for testing VO2peak in youth who have spina bifida and use a wheelchair for mobility and sport. The outcome measure of number of shuttles represents aerobic fitness and is also highly correlated with both anaerobic performance and agility. It is not possible to predict VO2peak accurately by using the number of shuttles completed. Moreover, the Shuttle Ride Test is highly reliable in youth with spina bifida, with a good smallest detectable change for the

  20. Cardiorespiratory Fitness and Reclassification of Risk for Incidence of Heart Failure: The Veterans Exercise Testing Study.

    PubMed

    Myers, Jonathan; Kokkinos, Peter; Chan, Khin; Dandekar, Eshan; Yilmaz, Bilge; Nagare, Atul; Faselis, Charles; Soofi, Muhammad

    2017-06-01

    It is well established that cardiorespiratory fitness (CRF) is inversely associated with cardiovascular and all-cause mortality. However, little is known regarding the association between CRF and incidence of heart failure (HF). Between 1987 and 2014, we assessed CRF in 21 080 HF-free subjects (58.3±11 years) at the Veterans Affairs Medical Centers in Washington, DC, and Palo Alto, CA. Subjects were classified by age-specific quintiles of CRF. Multivariable Cox models were used to determine the association between HF incidence and clinical and exercise test variables. Reclassification characteristics of fitness relative to standard clinical risk factors were determined using the category-free net reclassification improvement and integrated discrimination improvement indices. During the follow-up (mean 12.3±7.4 years), 1902 subjects developed HF (9.0%; average annual incidence rate, 7.4 events per 1000 person-years). When CRF was considered as a binary variable (unfit/fit), low fitness was the strongest predictor of risk for HF among clinical and exercise test variables (hazard ratio, 1.91; 95% confidence interval, 1.74-2.09; P <0.001). In a fully adjusted model with the least-fit group as the reference, there was a graded and progressive reduction in risk for HF as fitness level was higher. Risks for developing HF were 36%, 41%, 67%, and 76% lower among increasing quintiles of fitness compared with the least-fit subjects ( P <0.001). Adding CRF to standard risk factors resulted in a net reclassification improvement of 0.37 ( P <0.001). CRF is strongly, inversely, and independently associated with the incidence of HF in veterans referred for exercise testing. © 2017 American Heart Association, Inc.

  1. A real-time, quantitative PCR protocol for assessing the relative parasitemia of Leucocytozoon in waterfowl.

    PubMed

    Smith, Matthew M; Schmutz, Joel; Apelgren, Chloe; Ramey, Andrew M

    2015-04-01

    Microscopic examination of blood smears can be effective at diagnosing and quantifying hematozoa infections. However, this method requires highly trained observers, is time consuming, and may be inaccurate for detection of infections at low levels of parasitemia. To develop a molecular methodology for identifying and quantifying Leucocytozoon parasite infection in wild waterfowl (Anseriformes), we designed a real-time, quantitative PCR protocol to amplify Leucocytozoon mitochondrial DNA using TaqMan fluorogenic probes and validated our methodology using blood samples collected from waterfowl in interior Alaska during late summer and autumn (n=105). By comparing our qPCR results to those derived from a widely used nested PCR protocol, we determined that our assay showed high levels of sensitivity (91%) and specificity (100%) in detecting Leucocytozoon DNA from host blood samples. Additionally, results of a linear regression revealed significant correlation between the raw measure of parasitemia produced by our qPCR assay (Ct values) and numbers of parasites observed on blood smears (R(2)=0.694, P=0.003), indicating that our assay can reliably determine the relative parasitemia levels among samples. This methodology provides a powerful new tool for studies assessing effects of haemosporidian infection in wild avian species. Published by Elsevier B.V.

  2. Mapcurves: a quantitative method for comparing categorical maps.

    Treesearch

    William W. Hargrove; M. Hoffman Forrest; Paul F. Hessburg

    2006-01-01

    We present Mapcurves, a quantitative goodness-of-fit (GOF) method that unambiguously shows the degree of spatial concordance between two or more categorical maps. Mapcurves graphically and quantitatively evaluate the degree of fit among any number of maps and quantify a GOF for each polygon, as well as the entire map. The Mapcurve method indicates a perfect fit even if...

  3. Proposal for a candidate core-set of fitness and strength tests for patients with childhood or adult idiopathic inflammatory myopathies

    PubMed Central

    van der Stap, Djamilla K.D.; Rider, Lisa G.; Alexanderson, Helene; Huber, Adam M.; Gualano, Bruno; Gordon, Patrick; van der Net, Janjaap; Mathiesen, Pernille; Johnson, Liam G.; Ernste, Floranne C.; Feldman, Brian M.; Houghton, Kristin M.; Singh-Grewal, Davinder; Kutzbach, Abraham Garcia; Munters, Li Alemo; Takken, Tim

    2015-01-01

    OBJECTIVES Currently there are no evidence-based recommendations regarding which fitness and strength tests to use for patients with childhood or adult idiopathic inflammatory myopathies (IIM). This hinders clinicians and researchers in choosing the appropriate fitness- or muscle strength-related outcome measures for these patients. Through a Delphi survey, we aimed to identify a candidate core-set of fitness and strength tests for children and adults with IIM. METHODS Fifteen experts participated in a Delphi survey that consisted of five stages to achieve a consensus. Using an extensive search of published literature and through the expertise of the experts, a candidate core-set based on expert opinion and clinimetric properties was developed. Members of the International Myositis Assessment and Clinical Studies Group (IMACS) were invited to review this candidate core-set during the final stage, which led to a final candidate core-set. RESULTS A core-set of fitness- and strength-related outcome measures was identified for children and adults with IIM. For both children and adults, different tests were identified and selected for maximal aerobic fitness, submaximal aerobic fitness, anaerobic fitness, muscle strength tests and muscle function tests. CONCLUSIONS The core-set of fitness and strength-related outcome measures provided by this expert consensus process will assist practitioners and researchers in deciding which tests to use in IIM patients. This will improve the uniformity of fitness and strength tests across studies, thereby facilitating the comparison of study results and therapeutic exercise program outcomes among patients with IIM. PMID:26568594

  4. Can Programmed or Self-Selected Physical Activity Affect Physical Fitness of Adolescents?

    PubMed Central

    Neto, Cláudio F.; Neto, Gabriel R.; Araújo, Adenilson T.; Sousa, Maria S. C.; Sousa, Juliana B. C.; Batista, Gilmário R.; Reis, Victor M. M. R.

    2014-01-01

    The aim of this study was to verify the effects of programmed and self-selected physical activities on the physical fitness of adolescents. High school adolescents, aged between 15 and 17 years, were divided into two experimental groups: a) a self-selected physical activity group (PAS) with 55 students (aged 15.7 ± 0.7 years), who performed physical activities with self-selected rhythm at the following sports: basketball, volleyball, handball, futsal and swimming; and b) a physical fitness training group (PFT) with 53 students (aged 16.0 ± 0.7 years), who performed programmed physical fitness exercises. Both types of activity were developed during 60 min classes. To assess physical fitness the PROESP-BR protocol was used. The statistical analysis was performed by repeated measures ANOVA. The measurements of pre and post-tests showed significantly different values after PFT in: 9 minute running test, medicine ball throw, horizontal jump, abdominal endurance, running speed and flexibility. After PAS differences were detected in abdominal endurance, agility, running speed and flexibility. The intervention with programmed physical activity promoted more changes in the physical abilities; however, in the self-selected program, agility was improved probably because of the practice of sports. Therefore, physical education teachers can use PFT to improve cardiorespiratory fitness and power of lower and upper limbs and PAS to improve agility of high school adolescents. PMID:25713652

  5. Evaluation of Cooper 12-minute walk/run test as a marker of cardiorespiratory fitness in young urban children with persistent asthma.

    PubMed

    Weisgerber, Michael; Danduran, Michael; Meurer, John; Hartmann, Kathryn; Berger, Stuart; Flores, Glenn

    2009-07-01

    To evaluate Cooper 12-minute run/walk test (CT12) as a one-time estimate of cardiorespiratory fitness and marker of fitness change compared with treadmill fitness testing in young children with persistent asthma. A cohort of urban children with asthma participated in the asthma and exercise program and a subset completed pre- and postintervention fitness testing. Treadmill fitness testing was conducted by an exercise physiologist in the fitness laboratory at an academic children's hospital. CT12 was conducted in a college recreation center gymnasium. Forty-five urban children with persistent asthma aged 7 to 14 years participated in exercise interventions. A subset of 19 children completed pre- and postintervention exercise testing. Participants completed a 9-week exercise program where they participated in either swimming or golf 3 days a week for 1 hour. A subset of participants completed fitness testing by 2 methods before and after program completion. CT12 results (meters), maximal oxygen consumption ((.)Vo2max) (mL x kg(-1) x min(-1)), and treadmill exercise time (minutes). CT12 and maximal oxygen consumption were moderately correlated (preintervention: 0.55, P = 0.003; postintervention: 0.48, P = 0.04) as one-time measures of fitness. Correlations of the tests as markers of change over time were poor and nonsignificant. In children with asthma, CT12 is a reasonable one-time estimate of fitness but a poor marker of fitness change over time.

  6. The association between cardiorespiratory fitness and cardiovascular risk may be modulated by known cardiovascular risk factors.

    PubMed

    Erez, Aharon; Kivity, Shaye; Berkovitch, Anat; Milwidsky, Assi; Klempfner, Robert; Segev, Shlomo; Goldenberg, Ilan; Sidi, Yechezkel; Maor, Elad

    2015-06-01

    We aimed to evaluate whether reduced cardiovascular fitness has a direct or indirect effect for the development of cardiovascular disease. We investigated 15,595 men and women who were annually screened in a tertiary medical center. All subjects were free of ischemic heart disease and had completed maximal exercise stress test according to the Bruce protocol at their first visit. Fitness was categorized into age- and sex-specific quintiles (Q) according to Bruce protocol treadmill time with Q1 as lowest fitness. Subjects were categorized at baseline into 3 groups: low fitness (Q1), moderate fitness (Q2-Q4), and high fitness (Q5). The primary end point of the current analysis was the development of a first cardiovascular event during follow-up. Mean age of study patients was 48 ± 10 years, and 73% were men. A total of 679 events occurred during 92,092 person-years of follow-up. Kaplan-Meier survival analysis showed that the cumulative probability of cardiovascular events at 6 years was significantly higher among subjects with low fitness (P < .001). Low fitness was associated with known cardiovascular risk factors, including hypercholesterolemia (odds ratio [OR] 1.58, 95% CI 1.31-1.89), diabetes mellitus (OR 2.32, 95% CI 1.58-3.41), and obesity (OR 10.46, 95% CI 8.43-12.98). The effect of low fitness on cardiovascular events was no longer significant when including diabetes mellitus, hypercholesterolemia, and obesity as mediators (hazard ratio 0.99, 95% CI 0.82-1.19). The association between cardiovascular fitness and adverse cardiovascular outcomes may be modulated through traditional cardiovascular risk factors. These findings need to be further validated in prospective clinical trials. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Assessment of and standardization for quantitative nondestructive test

    NASA Technical Reports Server (NTRS)

    Neuschaefer, R. W.; Beal, J. B.

    1972-01-01

    Present capabilities and limitations of nondestructive testing (NDT) as applied to aerospace structures during design, development, production, and operational phases are assessed. It will help determine what useful structural quantitative and qualitative data may be provided from raw materials to vehicle refurbishment. This assessment considers metal alloys systems and bonded composites presently applied in active NASA programs or strong contenders for future use. Quantitative and qualitative data has been summarized from recent literature, and in-house information, and presented along with a description of those structures or standards where the information was obtained. Examples, in tabular form, of NDT technique capabilities and limitations have been provided. NDT techniques discussed and assessed were radiography, ultrasonics, penetrants, thermal, acoustic, and electromagnetic. Quantitative data is sparse; therefore, obtaining statistically reliable flaw detection data must be strongly emphasized. The new requirements for reusable space vehicles have resulted in highly efficient design concepts operating in severe environments. This increases the need for quantitative NDT evaluation of selected structural components, the end item structure, and during refurbishment operations.

  8. Aerobic fitness in women and responses to lower body negative pressure

    NASA Technical Reports Server (NTRS)

    Frey, Mary Anne Bassett; Mathes, Karen L.; Hoffler, G. Wyckliffe

    1987-01-01

    The role of tolerance to orthostatic stress in the maintenance of high aerobic fitness in women was investigated by examining the responses of heart rate, stroke volume, cardiac output, Heather index of contractility, arterial pressure, peripheral resistance, change in calf circumference, and thoracic impedance of healthy female subjects to lower body negative pressure (LBNP) applied for 5 min at -50 mm Hg or until a subject became presyncopal. The testing protocol involved a stepwise reduction in pressure and consisted of two parts: an LBNP test in supine position followed by a treadmill test to peak aerobic capacity. Women were found to exhibit the same response pattern to LBNP as was previously reported by Convertino et al. (1984) for men. The results do not support the hypothesis that orthostatic tolerance in women is inversely related to aerobic fitness, as demonstrated by a finding that the peak aerobic capacity of subjects who became presyncopal did not differ from the peak of the tolerant subjects, and that hemodynamic responses to LBNPL were not a function of aerobic capacity.

  9. An autoanalyzer test for the quantitation of platelet-associated IgG

    NASA Technical Reports Server (NTRS)

    Levitan, Nathan; Teno, Richard A.; Szymanski, Irma O.

    1986-01-01

    A new quantitative antiglobulin consumption (QAC) test for the measurement of platelet-associated IgG is described. In this test washed platelets are incubated with anti-IgG at a final dilution of 1:2 million. The unneutralized fraction of anti-IgG remaining in solution is then measured with an Autoanalyzer and soluble IgG is used for calibration. The dose-response curves depicting the percent neutralization of anti-IgG by platelets and by soluble IgG were compared in detail and found to be nearly identical, indicating that platelet-associated IgG can be accurately quantitated by this method. The mean IgG values were 2287 molecules/platelet for normal adults and 38,112 molecules/platelet for ITP patients. The Autoanalyzer QAC test is a sensitive and reproducible assay for the quantitation of platelet-associated IgG.

  10. A test protocol for assessing the hearing status of students with special needs.

    PubMed

    Chen, Hsiao-Chuan; Wang, Nan-Mai; Chiu, Wen-Chen; Liu, Shu-Yu; Chang, Yi-Ping; Lin, Pei-Yu; Chung, King

    2014-10-01

    Individuals with disabilities are often reported to have a high prevalence of undetected hearing disorders/loss, but there is no standardized hearing test protocol for this population. The purposes of this study were (1) to examine the hearing status of students with special needs in Taiwan, and (2) to investigate the use of an on-site hearing test protocol that would adequately detect hearing problems in this population and reduce unnecessary referrals for off-site follow-up services. A total of 238 students enrolled in two schools for special education and one habilitation center participated in the study. Most students had intellectual disabilities and some also had additional syndromes or disorders. A hearing screening protocol including otoscopy, tympanometry, and distortion product otoacoustic emissions was administered to examine students' outer, middle, and inner ear functions, respectively. Pure tone tests were then administered as an on-site follow-up for those who failed or could not be tested using the screening protocol. Only 32.4% of students passed. When administered alone, the referral rate of otoscopy, tympanometry, and otoacoustic emissions were 38.7%, 46.0%, and 48.5%, respectively. The integration of these subtests revealed 52.1% of students needed follow-up services, 11.8% could not be tested, 2.5% had documented hearing loss, and 1.3% needed to be monitored because of negative middle ear pressure. The inclusion of pure tone audiometry increased the passing rate by 9.9% and provided information on hearing sensitivity for an additional 8.6% of students. Hearing assessments and regular hearing screening should be provided as an integral part of health care services for individuals with special needs because of high occurrences of excessive cerumen, middle ear dysfunction, and sensorineural hearing loss. The training of care-givers and teachers of students with special needs is encouraged so that they can help identify hearing problems and reduce

  11. Submaximal Treadmill Exercise Test to Predict VO[subscript 2]max in Fit Adults

    ERIC Educational Resources Information Center

    Vehrs, Pat R.; George, James D.; Fellingham, Gilbert W.; Plowman, Sharon A.; Dustman-Allen, Kymberli

    2007-01-01

    This study was designed to develop a single-stage submaximal treadmill jogging (TMJ) test to predict VO[subscript 2]max in fit adults. Participants (N = 400; men = 250 and women = 150), ages 18 to 40 years, successfully completed a maximal graded exercise test (GXT) at 1 of 3 laboratories to determine VO[subscript 2]max. The TMJ test was completed…

  12. Effects of the Youth Fit 4 Life physical activity/nutrition protocol on body mass index, fitness and targeted social cognitive theory variables in 9- to 12-year-olds during after-school care.

    PubMed

    Annesi, James J; Walsh, Stephanie M; Greenwood, Brittney L; Mareno, Nicole; Unruh-Rewkowski, Jennifer L

    2017-04-01

    Childhood overweight and obesity is unacceptably high in industrialised nations. School-based interventions have largely been atheoretical and ineffective. This study aimed to test a new theory-based protocol for its effects on measures of fitness and body mass index (BMI), and its proposed psychosocial mediators, during elementary after-school (out-of-school hours) care. Nine- to 12-year-old participants of YMCA-based after-school care in the southeastern Unites States were randomised into either the experimental Youth Fit 4 Life (YF4L) treatment group (n = 86) or a typical care group (n = 55) for 45 min/day. YF4L is based on social cognitive theory, emphasising mastery over physical activities and the development of self-management/self-regulatory skills to support healthy behaviours. Physiological and psychosocial variables were assessed over a 9-month elementary school year. Of the overall sample, 28% were overweight or obese at baseline. YF4L was associated with significantly greater improvements in BMI, and measures of self-regulation, mood, self-efficacy, cardiovascular endurance and strength over both 3 and 9 months. Changes in self-regulation, mood and self-efficacy significantly mediated the treatment type-BMI relationship over both 3 months (R 2 = 0.12, P = 0.002) and 9 months (R 2 = 0.13, P = 0.001), with change in self-regulation being a significant independent mediator. Changes in BMI and self-regulation reciprocally reinforced one another. Gender was not a significant moderator of those relationships. The YF4L treatment mitigated rise in BMI in 9- to 12-year-old enrollees of after-school care. The treatment's basis in social cognitive theory was supported. Because of its positive effects and ability to utilise existing staff, large-scale application is warranted after sufficient replication. © 2017 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  13. A comparison of fit of CNC-milled titanium and zirconia frameworks to implants.

    PubMed

    Abduo, Jaafar; Lyons, Karl; Waddell, Neil; Bennani, Vincent; Swain, Michael

    2012-05-01

    Computer numeric controlled (CNC) milling was proven to be predictable method to fabricate accurately fitting implant titanium frameworks. However, no data are available regarding the fit of CNC-milled implant zirconia frameworks. To compare the precision of fit of implant frameworks milled from titanium and zirconia and relate it to peri-implant strain development after framework fixation. A partially edentulous epoxy resin models received two Branemark implants in the areas of the lower left second premolar and second molar. From this model, 10 identical frameworks were fabricated by mean of CNC milling. Half of them were made from titanium and the other half from zirconia. Strain gauges were mounted close to the implants to qualitatively and quantitatively assess strain development as a result of framework fitting. In addition, the fit of the framework implant interface was measured using an optical microscope, when only one screw was tightened (passive fit) and when all screws were tightened (vertical fit). The data was statistically analyzed using the Mann-Whitney test. All frameworks produced measurable amounts of peri-implant strain. The zirconia frameworks produced significantly less strain than titanium. Combining the qualitative and quantitative information indicates that the implants were under vertical displacement rather than horizontal. The vertical fit was similar for zirconia (3.7 µm) and titanium (3.6 µm) frameworks; however, the zirconia frameworks exhibited a significantly finer passive fit (5.5 µm) than titanium frameworks (13.6 µm). CNC milling produced zirconia and titanium frameworks with high accuracy. The difference between the two materials in terms of fit is expected to be of minimal clinical significance. The strain developed around the implants was more related to the framework fit rather than framework material. © 2011 Wiley Periodicals, Inc.

  14. The 6-min push test is reliable and predicts low fitness in spinal cord injury.

    PubMed

    Cowan, Rachel E; Callahan, Morgan K; Nash, Mark S

    2012-10-01

    The objective of this study is to assess 6-min push test (6MPT) reliability, determine whether the 6MPT is sensitive to fitness differences, and assess if 6MPT distance predicts fitness level in persons with spinal cord injury (SCI) or disease. Forty individuals with SCI who could self-propel a manual wheelchair completed an incremental arm crank peak oxygen consumption assessment and two 6MPTs across 3 d (37% tetraplegia (TP), 63% paraplegia (PP), 85% men, 70% white, 63% Hispanic, mean age = 34 ± 10 yr, mean duration of injury = 13 ± 10 yr, and mean body mass index = 24 ± 5 kg.m). Intraclass correlation and Bland-Altman plots assessed 6MPT distance (m) reliability. Mann-Whitney U test compared 6MPT distance (m) of high and low fitness groups for TP and PP. The fitness status prediction was developed using N = 30 and validated in N = 10 (validation group (VG)). A nonstatistical prediction approach, below or above a threshold distance (TP = 445 m and PP = 604 m), was validated statistically by binomial logistic regression. Accuracy, sensitivity, and specificity were computed to evaluate the threshold approach. Intraclass correlation coefficients exceeded 0.90 for the whole sample and the TP/PP subsets. High fitness persons propelled farther than low fitness persons for both TP/PP (both P < 0.05). Binomial logistic regression (P < 0.008) predicted the same fitness levels in the VG as the threshold approach. In the VG, overall accuracy was 70%. Eighty-six percent of low fitness persons were correctly identified (sensitivity), and 33% of high fitness persons were correctly identified (specificity). The 6MPT may be a useful tool for SCI clinicians and researchers. 6MPT distance demonstrates excellent reliability and is sensitive to differences in fitness level. 6MPT distances less than a threshold distance may be an effective approach to identify low fitness in person with SCI.

  15. Power and sensitivity of alternative fit indices in tests of measurement invariance.

    PubMed

    Meade, Adam W; Johnson, Emily C; Braddy, Phillip W

    2008-05-01

    Confirmatory factor analytic tests of measurement invariance (MI) based on the chi-square statistic are known to be highly sensitive to sample size. For this reason, G. W. Cheung and R. B. Rensvold (2002) recommended using alternative fit indices (AFIs) in MI investigations. In this article, the authors investigated the performance of AFIs with simulated data known to not be invariant. The results indicate that AFIs are much less sensitive to sample size and are more sensitive to a lack of invariance than chi-square-based tests of MI. The authors suggest reporting differences in comparative fit index (CFI) and R. P. McDonald's (1989) noncentrality index (NCI) to evaluate whether MI exists. Although a general value of change in CFI (.002) seemed to perform well in the analyses, condition specific change in McDonald's NCI values exhibited better performance than a single change in McDonald's NCI value. Tables of these values are provided as are recommendations for best practices in MI testing. PsycINFO Database Record (c) 2008 APA, all rights reserved.

  16. A Women-Only Comparison of the U.S. Air Force Fitness Test and the Marine Combat Fitness Test

    DTIC Science & Technology

    2012-03-01

    Air Force established the Fitness Assessment Cell to conduct fitness assessments for all Air Force members and to encourage standardization in...objective. “The MCFT was specifically designed to evaluate strength, stamina , agility and coordination as well as overall anaerobic capacity” (Department...1308.1, “Service members must possess stamina and strength to perform, successfully, any mission,” and that “…each service develops a quality 78

  17. Selecting the most appropriate inferential statistical test for your quantitative research study.

    PubMed

    Bettany-Saltikov, Josette; Whittaker, Victoria Jane

    2014-06-01

    To discuss the issues and processes relating to the selection of the most appropriate statistical test. A review of the basic research concepts together with a number of clinical scenarios is used to illustrate this. Quantitative nursing research generally features the use of empirical data which necessitates the selection of both descriptive and statistical tests. Different types of research questions can be answered by different types of research designs, which in turn need to be matched to a specific statistical test(s). Discursive paper. This paper discusses the issues relating to the selection of the most appropriate statistical test and makes some recommendations as to how these might be dealt with. When conducting empirical quantitative studies, a number of key issues need to be considered. Considerations for selecting the most appropriate statistical tests are discussed and flow charts provided to facilitate this process. When nursing clinicians and researchers conduct quantitative research studies, it is crucial that the most appropriate statistical test is selected to enable valid conclusions to be made. © 2013 John Wiley & Sons Ltd.

  18. Quantitative Accelerated Life Testing of MEMS Accelerometers

    PubMed Central

    Bâzu, Marius; Gălăţeanu, Lucian; Ilian, Virgil Emil; Loicq, Jerome; Habraken, Serge; Collette, Jean-Paul

    2007-01-01

    Quantitative Accelerated Life Testing (QALT) is a solution for assessing the reliability of Micro Electro Mechanical Systems (MEMS). A procedure for QALT is shown in this paper and an attempt to assess the reliability level for a batch of MEMS accelerometers is reported. The testing plan is application-driven and contains combined tests: thermal (high temperature) and mechanical stress. Two variants of mechanical stress are used: vibration (at a fixed frequency) and tilting. Original equipment for testing at tilting and high temperature is used. Tilting is appropriate as application-driven stress, because the tilt movement is a natural environment for devices used for automotive and aerospace applications. Also, tilting is used by MEMS accelerometers for anti-theft systems. The test results demonstrated the excellent reliability of the studied devices, the failure rate in the “worst case” being smaller than 10-7h-1. PMID:28903265

  19. Correlation of Respirator Fit Measured on Human Subjects and a Static Advanced Headform

    PubMed Central

    Bergman, Michael S.; He, Xinjian; Joseph, Michael E.; Zhuang, Ziqing; Heimbuch, Brian K.; Shaffer, Ronald E.; Choe, Melanie; Wander, Joseph D.

    2015-01-01

    This study assessed the correlation of N95 filtering face-piece respirator (FFR) fit between a Static Advanced Headform (StAH) and 10 human test subjects. Quantitative fit evaluations were performed on test subjects who made three visits to the laboratory. On each visit, one fit evaluation was performed on eight different FFRs of various model/size variations. Additionally, subject breathing patterns were recorded. Each fit evaluation comprised three two-minute exercises: “Normal Breathing,” “Deep Breathing,” and again “Normal Breathing.” The overall test fit factors (FF) for human tests were recorded. The same respirator samples were later mounted on the StAH and the overall test manikin fit factors (MFF) were assessed utilizing the recorded human breathing patterns. Linear regression was performed on the mean log10-transformed FF and MFF values to assess the relationship between the values obtained from humans and the StAH. This is the first study to report a positive correlation of respirator fit between a headform and test subjects. The linear regression by respirator resulted in R2 = 0.95, indicating a strong linear correlation between FF and MFF. For all respirators the geometric mean (GM) FF values were consistently higher than those of the GM MFF. For 50% of respirators, GM FF and GM MFF values were significantly different between humans and the StAH. For data grouped by subject/respirator combinations, the linear regression resulted in R2 = 0.49. A weaker correlation (R2 = 0.11) was found using only data paired by subject/respirator combination where both the test subject and StAH had passed a real-time leak check before performing the fit evaluation. For six respirators, the difference in passing rates between the StAH and humans was < 20%, while two respirators showed a difference of 29% and 43%. For data by test subject, GM FF and GM MFF values were significantly different for 40% of the subjects. Overall, the advanced headform system has

  20. Test-retest reliability of a balance testing protocol with external perturbations in young healthy adults.

    PubMed

    Robbins, Shawn M; Caplan, Ryan M; Aponte, Daniel I; St-Onge, Nancy

    2017-10-01

    External perturbations are utilized to challenge balance and mimic realistic balance threats in patient populations. The reliability of such protocols has not been established. The purpose was to examine test-retest reliability of balance testing with external perturbations. Healthy adults (n=34; mean age 23 years) underwent balance testing over two visits. Participants completed ten balance conditions in which the following parameters were combined: perturbation or non-perturbation, single or double leg, and eyes open or closed. Three trials were collected for each condition. Data were collected on a force plate and external perturbations were applied by translating the plate. Force plate center of pressure (CoP) data were summarized using 13 different CoP measures. Test-retest reliability was examined using intraclass correlation coefficients (ICC) and Bland-Altman plots. CoP measures of total speed and excursion in both anterior-posterior and medial-lateral directions generally had acceptable ICC values for perturbation conditions (ICC=0.46 to 0.87); however, many other CoP measures (e.g. range, area of ellipse) had unacceptable test-retest reliability (ICC<0.70). Improved CoP measures were present on the second visit indicating a potential learning effect. Non-perturbation conditions generally produced more reliable CoP measures than perturbation conditions during double leg standing, but not single leg standing. Therefore, changes to balance testing protocols that include external perturbations should be made to improve test-retest reliability and diminish learning including more extensive participant training and increasing the number of trials. CoP measures that consider all data points (e.g. total speed) are more reliable than those that only consider a few data points. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Physical Fitness Assessment.

    ERIC Educational Resources Information Center

    Valdes, Alice

    This document presents baseline data on physical fitness that provides an outline for assessing the physical fitness of students. It consists of 4 tasks and a 13-item questionnaire on fitness-related behaviors. The fitness test evaluates cardiorespiratory endurance by a steady state jog; muscular strength and endurance with a two-minute bent-knee…

  2. Angles-centroids fitting calibration and the centroid algorithm applied to reverse Hartmann test

    NASA Astrophysics Data System (ADS)

    Zhao, Zhu; Hui, Mei; Xia, Zhengzheng; Dong, Liquan; Liu, Ming; Liu, Xiaohua; Kong, Lingqin; Zhao, Yuejin

    2017-02-01

    In this paper, we develop an angles-centroids fitting (ACF) system and the centroid algorithm to calibrate the reverse Hartmann test (RHT) with sufficient precision. The essence of ACF calibration is to establish the relationship between ray angles and detector coordinates. Centroids computation is used to find correspondences between the rays of datum marks and detector pixels. Here, the point spread function of RHT is classified as circle of confusion (CoC), and the fitting of a CoC spot with 2D Gaussian profile to identify the centroid forms the basis of the centroid algorithm. Theoretical and experimental results of centroids computation demonstrate that the Gaussian fitting method has a less centroid shift or the shift grows at a slower pace when the quality of the image is reduced. In ACF tests, the optical instrumental alignments reach an overall accuracy of 0.1 pixel with the application of laser spot centroids tracking program. Locating the crystal at different positions, the feasibility and accuracy of ACF calibration are further validated to 10-6-10-4 rad root-mean-square error of the calibrations differences.

  3. Reliability of Fitness Tests Using Methods and Time Periods Common in Sport and Occupational Management

    PubMed Central

    Burnstein, Bryan D.; Steele, Russell J.; Shrier, Ian

    2011-01-01

    Context: Fitness testing is used frequently in many areas of physical activity, but the reliability of these measurements under real-world, practical conditions is unknown. Objective: To evaluate the reliability of specific fitness tests using the methods and time periods used in the context of real-world sport and occupational management. Design: Cohort study. Setting: Eighteen different Cirque du Soleil shows. Patients or Other Participants: Cirque du Soleil physical performers who completed 4 consecutive tests (6-month intervals) and were free of injury or illness at each session (n = 238 of 701 physical performers). Intervention(s): Performers completed 6 fitness tests on each assessment date: dynamic balance, Harvard step test, handgrip, vertical jump, pull-ups, and 60-second jump test. Main Outcome Measure(s): We calculated the intraclass coefficient (ICC) and limits of agreement between baseline and each time point and the ICC over all 4 time points combined. Results: Reliability was acceptable (ICC > 0.6) over an 18-month time period for all pairwise comparisons and all time points together for the handgrip, vertical jump, and pull-up assessments. The Harvard step test and 60-second jump test had poor reliability (ICC < 0.6) between baseline and other time points. When we excluded the baseline data and calculated the ICC for 6-month, 12-month, and 18-month time points, both the Harvard step test and 60-second jump test demonstrated acceptable reliability. Dynamic balance was unreliable in all contexts. Limit-of-agreement analysis demonstrated considerable intraindividual variability for some tests and a learning effect by administrators on others. Conclusions: Five of the 6 tests in this battery had acceptable reliability over an 18-month time frame, but the values for certain individuals may vary considerably from time to time for some tests. Specific tests may require a learning period for administrators. PMID:22488138

  4. Reliability of fitness tests using methods and time periods common in sport and occupational management.

    PubMed

    Burnstein, Bryan D; Steele, Russell J; Shrier, Ian

    2011-01-01

    Fitness testing is used frequently in many areas of physical activity, but the reliability of these measurements under real-world, practical conditions is unknown. To evaluate the reliability of specific fitness tests using the methods and time periods used in the context of real-world sport and occupational management. Cohort study. Eighteen different Cirque du Soleil shows. Cirque du Soleil physical performers who completed 4 consecutive tests (6-month intervals) and were free of injury or illness at each session (n = 238 of 701 physical performers). Performers completed 6 fitness tests on each assessment date: dynamic balance, Harvard step test, handgrip, vertical jump, pull-ups, and 60-second jump test. We calculated the intraclass coefficient (ICC) and limits of agreement between baseline and each time point and the ICC over all 4 time points combined. Reliability was acceptable (ICC > 0.6) over an 18-month time period for all pairwise comparisons and all time points together for the handgrip, vertical jump, and pull-up assessments. The Harvard step test and 60-second jump test had poor reliability (ICC < 0.6) between baseline and other time points. When we excluded the baseline data and calculated the ICC for 6-month, 12-month, and 18-month time points, both the Harvard step test and 60-second jump test demonstrated acceptable reliability. Dynamic balance was unreliable in all contexts. Limit-of-agreement analysis demonstrated considerable intraindividual variability for some tests and a learning effect by administrators on others. Five of the 6 tests in this battery had acceptable reliability over an 18-month time frame, but the values for certain individuals may vary considerably from time to time for some tests. Specific tests may require a learning period for administrators.

  5. A protocol for bladder cancer screening and medical surveillance among high-risk groups: The Drake Health Registry experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marsh, G.M.; Callahan, C.; Pavlock, D.

    In 1986, the Drake Health Registry Study initiated bladder cancer screening for 366 persons at high risk because of occupational exposure to beta-naphthylamine. The Drake Health Registry Study screening protocol consists of urinalysis, Papanicolaou cytology, and quantitative fluorescence image analysis. A positive screening test qualifies participants for a full diagnostic evaluation. The screening protocol has been modified during the first 3 years of the program's existence to address unexpected patterns of test results and to incorporate advances in screening technology. The current protocol, which has a two-tiered screening schedule, has been utilized successfully for 15 months. Of the 26 positivemore » results to date most have been based on abnormal Papanicolaou cytology and/or quantitative fluorescence image analysis. Bladder abnormalities were cited among most of the 18 study members who underwent diagnostic evaluation, including chronic cystitis, inflammation, hyperplasia, and dysplasia. We conclude that the screening program is detecting very early changes in a relatively young cohort and that these persons must be monitored over a number of years to ensure adequate medical surveillance.« less

  6. Development of a comprehensive performance-testing protocol for competitive surfers.

    PubMed

    Sheppard, Jeremy M; Nimphius, Sophia; Haff, Greg G; Tran, Tai T; Spiteri, Tania; Brooks, Hedda; Slater, Gary; Newton, Robert U

    2013-09-01

    Appropriate and valid testing protocols for evaluating the physical performances of surfing athletes are not well refined. The purpose of this project was to develop, refine, and evaluate a testing protocol for use with elite surfers, including measures of anthropometry, strength and power, and endurance. After pilot testing and consultation with athletes, coaches, and sport scientists, a specific suite of tests was developed. Forty-four competitive junior surfers (16.2 ± 1.3 y, 166.3 ± 7.3 cm, 57.9 ± 8.5 kg) participated in this study involving a within-day repeated-measures analysis, using an elite junior group of 22 international competitors (EJG), to establish reliability of the measures. To reflect validity of the testing measures, a comparison of performance results was then undertaken between the EJG and an age-matched competitive junior group of 22 nationally competitive surfers (CJG). Percent typical error of measurement (%TEM) for primary variables gained from the assessments ranged from 1.1% to 3.0%, with intraclass correlation coefficients ranging from .96 to .99. One-way analysis of variance revealed that the EJG had lower skinfolds (P = .005, d = 0.9) than the CJG, despite no difference in stature (P = .102) or body mass (P = .827). The EJG were faster in 15-m sprint-paddle velocity (P < .001, d = 1.3) and had higher lower-body isometric peak force (P = .04, d = 0.7) and superior endurance-paddling velocity (P = .008, d = 0.9). The relatively low %TEM of these tests in this population allows for high sensitivity to detect change. The results of this study suggest that competitively superior junior surfers are leaner and possess superior strength, paddling power, and paddling endurance.

  7. An Empirical Study on Raman Peak Fitting and Its Application to Raman Quantitative Research.

    PubMed

    Yuan, Xueyin; Mayanovic, Robert A

    2017-10-01

    Fitting experimentally measured Raman bands with theoretical model profiles is the basic operation for numerical determination of Raman peak parameters. In order to investigate the effects of peak modeling using various algorithms on peak fitting results, the representative Raman bands of mineral crystals, glass, fluids as well as the emission lines from a fluorescent lamp, some of which were measured under ambient light whereas others under elevated pressure and temperature conditions, were fitted using Gaussian, Lorentzian, Gaussian-Lorentzian, Voigtian, Pearson type IV, and beta profiles. From the fitting results of the Raman bands investigated in this study, the fitted peak position, intensity, area and full width at half-maximum (FWHM) values of the measured Raman bands can vary significantly depending upon which peak profile function is used in the fitting, and the most appropriate fitting profile should be selected depending upon the nature of the Raman bands. Specifically, the symmetric Raman bands of mineral crystals and non-aqueous fluids are best fit using Gaussian-Lorentzian or Voigtian profiles, whereas the asymmetric Raman bands are best fit using Pearson type IV profiles. The asymmetric O-H stretching vibrations of H 2 O and the Raman bands of soda-lime glass are best fit using several Gaussian profiles, whereas the emission lines from a florescent light are best fit using beta profiles. Multiple peaks that are not clearly separated can be fit simultaneously, provided the residuals in the fitting of one peak will not affect the fitting of the remaining peaks to a significant degree. Once the resolution of the Raman spectrometer has been properly accounted for, our findings show that the precision in peak position and intensity can be improved significantly by fitting the measured Raman peaks with appropriate profiles. Nevertheless, significant errors in peak position and intensity were still observed in the results from fitting of weak and wide Raman

  8. Test-retest reliability of jump execution variables using mechanography: a comparison of jump protocols.

    PubMed

    Fitzgerald, John S; Johnson, LuAnn; Tomkinson, Grant; Stein, Jesse; Roemmich, James N

    2018-05-01

    Mechanography during the vertical jump may enhance screening and determining mechanistic causes underlying physical performance changes. Utility of jump mechanography for evaluation is limited by scant test-retest reliability data on force-time variables. This study examined the test-retest reliability of eight jump execution variables assessed from mechanography. Thirty-two women (mean±SD: age 20.8 ± 1.3 yr) and 16 men (age 22.1 ± 1.9 yr) attended a familiarization session and two testing sessions, all one week apart. Participants performed two variations of the squat jump with squat depth self-selected and controlled using a goniometer to 80º knee flexion. Test-retest reliability was quantified as the systematic error (using effect size between jumps), random error (using coefficients of variation), and test-retest correlations (using intra-class correlation coefficients). Overall, jump execution variables demonstrated acceptable reliability, evidenced by small systematic errors (mean±95%CI: 0.2 ± 0.07), moderate random errors (mean±95%CI: 17.8 ± 3.7%), and very strong test-retest correlations (range: 0.73-0.97). Differences in random errors between controlled and self-selected protocols were negligible (mean±95%CI: 1.3 ± 2.3%). Jump execution variables demonstrated acceptable reliability, with no meaningful differences between the controlled and self-selected jump protocols. To simplify testing, a self-selected jump protocol can be used to assess force-time variables with negligible impact on measurement error.

  9. Quantitative Accelerated Life Testing of MEMS Accelerometers.

    PubMed

    Bâzu, Marius; Gălăţeanu, Lucian; Ilian, Virgil Emil; Loicq, Jerome; Habraken, Serge; Collette, Jean-Paul

    2007-11-20

    Quantitative Accelerated Life Testing (QALT) is a solution for assessing thereliability of Micro Electro Mechanical Systems (MEMS). A procedure for QALT is shownin this paper and an attempt to assess the reliability level for a batch of MEMSaccelerometers is reported. The testing plan is application-driven and contains combinedtests: thermal (high temperature) and mechanical stress. Two variants of mechanical stressare used: vibration (at a fixed frequency) and tilting. Original equipment for testing at tiltingand high temperature is used. Tilting is appropriate as application-driven stress, because thetilt movement is a natural environment for devices used for automotive and aerospaceapplications. Also, tilting is used by MEMS accelerometers for anti-theft systems. The testresults demonstrated the excellent reliability of the studied devices, the failure rate in the"worst case" being smaller than 10 -7 h -1 .

  10. Quantitative somatosensory testing of the penis: optimizing the clinical neurological examination.

    PubMed

    Bleustein, Clifford B; Eckholdt, Haftan; Arezzo, Joseph C; Melman, Arnold

    2003-06-01

    Quantitative somatosensory testing, including vibration, pressure, spatial perception and thermal thresholds of the penis, has demonstrated neuropathy in patients with a history of erectile dysfunction of all etiologies. We evaluated which measurement of neurological function of the penis was best at predicting erectile dysfunction and examined the impact of location on the penis for quantitative somatosensory testing measurements. A total of 107 patients were evaluated. All patients were required to complete the erectile function domain of the International Index of Erectile Function (IIEF) questionnaire, of whom 24 had no complaints of erectile dysfunction and scored within the "normal" range on the IIEF. Patients were subsequently tested on ventral middle penile shaft, proximal dorsal midline penile shaft and glans penis (with foreskin retracted) for vibration, pressure, spatial perception, and warm and cold thermal thresholds. Mixed models repeated measures analysis of variance controlling for age, diabetes and hypertension revealed that method of measurement (quantitative somatosensory testing) was predictive of IIEF score (F = 209, df = 4,1315, p <0.001), while site of measurement on the penis was not. To determine the best method of measurement, we used hierarchical regression, which revealed that warm temperature was the best predictor of erectile dysfunction with pseudo R(2) = 0.19, p <0.0007. There was no significant improvement in predicting erectile dysfunction when another test was added. Using 37C and greater as the warm thermal threshold yielded a sensitivity of 88.5%, specificity 70.0% and positive predictive value 85.5%. Quantitative somatosensory testing using warm thermal threshold measurements taken at the glans penis can be used alone to assess the neurological status of the penis. Warm thermal thresholds alone offer a quick, noninvasive accurate method of evaluating penile neuropathy in an office setting.

  11. Phase calibration target for quantitative phase imaging with ptychography.

    PubMed

    Godden, T M; Muñiz-Piniella, A; Claverley, J D; Yacoot, A; Humphry, M J

    2016-04-04

    Quantitative phase imaging (QPI) utilizes refractive index and thickness variations that lead to optical phase shifts. This gives contrast to images of transparent objects. In quantitative biology, phase images are used to accurately segment cells and calculate properties such as dry mass, volume and proliferation rate. The fidelity of the measured phase shifts is of critical importance in this field. However to date, there has been no standardized method for characterizing the performance of phase imaging systems. Consequently, there is an increasing need for protocols to test the performance of phase imaging systems using well-defined phase calibration and resolution targets. In this work, we present a candidate for a standardized phase resolution target, and measurement protocol for the determination of the transfer of spatial frequencies, and sensitivity of a phase imaging system. The target has been carefully designed to contain well-defined depth variations over a broadband range of spatial frequencies. In order to demonstrate the utility of the target, we measure quantitative phase images on a ptychographic microscope, and compare the measured optical phase shifts with Atomic Force Microscopy (AFM) topography maps and surface profile measurements from coherence scanning interferometry. The results show that ptychography has fully quantitative nanometer sensitivity in optical path differences over a broadband range of spatial frequencies for feature sizes ranging from micrometers to hundreds of micrometers.

  12. A novel method to assess primary stability of press-fit acetabular cups.

    PubMed

    Crosnier, Emilie A; Keogh, Patrick S; Miles, Anthony W

    2014-11-01

    Initial stability is an essential prerequisite to achieve osseointegration of press-fit acetabular cups in total hip replacements. Most in vitro methods that assess cup stability do not reproduce physiological loading conditions and use simplified acetabular models with a spherical cavity. The aim of this study was to investigate the effect of bone density and acetabular geometry on cup stability using a novel method for measuring acetabular cup micromotion. A press-fit cup was inserted into Sawbones(®) foam blocks having different densities to simulate normal and osteoporotic bone variations and different acetabular geometries. The stability of the cup was assessed in two ways: (a) measurement of micromotion of the cup in 6 degrees of freedom under physiological loading and (b) uniaxial push-out tests. The results indicate that changes in bone substrate density and acetabular geometry affect the stability of press-fit acetabular cups. They also suggest that cups implanted into weaker, for example, osteoporotic, bone are subjected to higher levels of micromotion and are therefore more prone to loosening. The decrease in stability of the cup in the physiological model suggests that using simplified spherical cavities to model the acetabulum over-estimates the initial stability of press-fit cups. This novel testing method should provide the basis for a more representative protocol for future pre-clinical evaluation of new acetabular cup designs. © IMechE 2014.

  13. CONFOCAL MICROSCOPY SYSTEM PERFORMANCE: QA TESTS, QUANTITATION AND SPECTROSCOPY

    EPA Science Inventory

    Confocal Microscopy System Performance: QA tests, Quantitation and Spectroscopy.

    Robert M. Zucker 1 and Jeremy M. Lerner 2,
    1Reproductive Toxicology Division, National Health and Environmental Effects Research Laboratory, Office of Research Development, U.S. Environmen...

  14. Relationship of physical fitness test results and hockey playing potential in elite-level ice hockey players.

    PubMed

    Burr, Jaime F; Jamnik, Roni K; Baker, Joseph; Macpherson, Alison; Gledhill, Norman; McGuire, E J

    2008-09-01

    The primary purpose of this study was to determine the fitness variables with the highest capability for predicting hockey playing potential at the elite level as determined by entry draft selection order. We also examined the differences associated with the predictive abilities of the test components among playing positions. The secondary purpose of this study was to update the physiological profile of contemporary hockey players including positional differences. Fitness test results conducted by our laboratory at the National Hockey League Entry Draft combine were compared with draft selection order on a total of 853 players. Regression models revealed peak anaerobic power output to be important for higher draft round selection in all positions; however, the degree of importance of this measurement varied with playing position. The body index, which is a composite score of height, lean mass, and muscular development, was similarly important in all models, with differing influence by position. Removal of the goalies' data increased predictive capacity, suggesting that talent identification using physical fitness testing of this sort may be more appropriate for skating players. Standing long jump was identified as a significant predictor variable for forwards and defense and could be a useful surrogate for assessing overall hockey potential. Significant differences exist between the physiological profiles of current players based on playing position. There are also positional differences in the relative importance of anthropometric and fitness measures of off-ice hockey tests in relation to draft order. Physical fitness measures and anthropometric data are valuable in helping predict hockey playing potential. Emphasis on anthropometry should be used when comparing elite-level forwards, whereas peak anaerobic power and fatigue rate are more useful for differentiating between defense.

  15. Boron concentration measurements by alpha spectrometry and quantitative neutron autoradiography in cells and tissues treated with different boronated formulations and administration protocols.

    PubMed

    Bortolussi, Silva; Ciani, Laura; Postuma, Ian; Protti, Nicoletta; Luca Reversi; Bruschi, Piero; Ferrari, Cinzia; Cansolino, Laura; Panza, Luigi; Ristori, Sandra; Altieri, Saverio

    2014-06-01

    The possibility to measure boron concentration with high precision in tissues that will be irradiated represents a fundamental step for a safe and effective BNCT treatment. In Pavia, two techniques have been used for this purpose, a quantitative method based on charged particles spectrometry and a boron biodistribution imaging based on neutron autoradiography. A quantitative method to determine boron concentration by neutron autoradiography has been recently set-up and calibrated for the measurement of biological samples, both solid and liquid, in the frame of the feasibility study of BNCT. This technique was calibrated and the obtained results were cross checked with those of α spectrometry, in order to validate them. The comparisons were performed using tissues taken form animals treated with different boron administration protocols. Subsequently the quantitative neutron autoradiography was employed to measure osteosarcoma cell samples treated with BPA and with new boronated formulations. © 2013 Published by Elsevier Ltd.

  16. Wireless Authentication Protocol Implementation: Descriptions of a Zero-Knowledge Proof (ZKP) Protocol Implementation for Testing on Ground and Airborne Mobile Networks

    DTIC Science & Technology

    2015-01-01

    on AFRL’s small unmanned aerial vehicle (UAV) test bed . 15. SUBJECT TERMS Zero-Knowledge Proof Protocol Testing 16. SECURITY CLASSIFICATION OF...VERIFIER*** edition Version Information: Version 1.1.3 Version Details: Successful ZK authentication between two networked machines. Fixed a bug ...that causes intermittent bignum errors. Fixed a network hang bug and now allows continually authentication at the Verifier. Also now removing

  17. Cytokine Responses to Acute Exercise in Healthy Older Adults: The Effect of Cardiorespiratory Fitness

    PubMed Central

    Windsor, Mark T.; Bailey, Tom G.; Perissiou, Maria; Meital, Lara; Golledge, Jonathan; Russell, Fraser D.; Askew, Christopher D.

    2018-01-01

    Markers of chronic inflammation increase with aging, and are associated with cardiovascular disease prevalence and mortality. Increases in fitness with exercise training have been associated with lower circulating concentrations of cytokines known to have pro-inflammatory actions (such as interleukin-6 [IL-6]) and higher circulating concentrations of anti-inflammatory cytokines (interleukin-10 [IL-10]). However, the effect of cardiorespiratory fitness on acute cytokine responses to a single bout of exercise in healthy older individuals is unknown. We compared the response of plasma cytokines IL-6, tumor necrosis factor-alpha (TNF-α) and IL-10 to a bout of moderate-intensity continuous and higher-intensity interval exercise between older individuals with higher and lower levels of cardiorespiratory fitness. Sixteen lower-fit (VO2peak: 22.6±2.8 mL.kg−1.min−1) and fourteen higher-fit participants (VO2peak: 37.4±5.9 mL.kg−1.min−1) completed three 24 min experimental protocols in a randomized order: (1) moderate-intensity continuous exercise (40% of peak power output [PPO]); (2) higher-intensity interval exercise (12 × 1 min intervals at 70% PPO separated by 1 min periods at 10% PPO); or (3) non-exercise control. Plasma cytokines were measured at rest, immediately after, and during 90 min of recovery following exercise or control. Plasma IL-6 concentrations at baseline were greater in the higher-fit compared to the lower-fit group (P = 0.02), with no difference in plasma IL-10 or TNF-α concentrations at baseline between groups. Plasma IL-6 and IL-10 concentrations in both groups increased immediately after all protocols (IL-6: P = 0.02, IL-10: P < 0.01). However, there was no difference in the IL-6 and IL-10 response between the exercise and non-exercise (control) protocols. After all protocols, no changes in plasma TNF-α concentrations were observed in either the higher- or lower-fit groups. In this study, basal concentrations of circulating IL-6 were

  18. Reliability, Validity and Usefulness of 30–15 Intermittent Fitness Test in Female Soccer Players

    PubMed Central

    Čović, Nedim; Jelešković, Eldin; Alić, Haris; Rađo, Izet; Kafedžić, Erduan; Sporiš, Goran; McMaster, Daniel T.; Milanović, Zoran

    2016-01-01

    PURPOSE: The aim of this study was to examine the reliability, validity and usefulness of the 30–15IFT in competitive female soccer players. METHODS: Seventeen elite female soccer players participated in the study. A within subject test-retest study design was utilized to assess the reliability of the 30–15 intermittent fitness test (IFT). Seven days prior to 30–15IFT, subjects performed a continuous aerobic running test (CT) under laboratory conditions to assess the criterion validity of the 30–15IFT. End running velocity (VCT and VIFT), peak heart rate (HRpeak) and maximal oxygen consumption (VO2max) were collected and/or estimated for both tests. RESULTS: VIFT (ICC = 0.91; CV = 1.8%), HRpeak (ICC = 0.94; CV = 1.2%), and VO2max (ICC = 0.94; CV = 1.6%) obtained from the 30–15IFT were all deemed highly reliable (p > 0.05). Pearson product moment correlations between the CT and 30–15IFT for VO2max, HRpeak and end running velocity were large (r = 0.67, p = 0.013), very large (r = 0.77, p = 0.02) and large (r = 0.57, p = 0.042), respectively. CONCLUSION: Current findings suggest that the 30–15IFT is a valid and reliable intermittent aerobic fitness test of elite female soccer players. The findings have also provided practitioners with evidence to support the accurate detection of meaningful individual changes in VIFT of 0.5 km/h (1 stage) and HRpeak of 2 bpm. This information may assist coaches in monitoring “real” aerobic fitness changes to better inform training of female intermittent team sport athletes. Lastly, coaches could use the 30–15IFT as a practical alternative to laboratory based assessments to assess and monitor intermittent aerobic fitness changes in their athletes. PMID:27909408

  19. The FORCE Fitness Profile--Adding a Measure of Health-Related Fitness to the Canadian Armed Forces Operational Fitness Evaluation.

    PubMed

    Gagnon, Patrick; Spivock, Michael; Reilly, Tara; Mattie, Paige; Stockbrugger, Barry

    2015-11-01

    In 2013, the Canadian Armed Forces (CAF) implemented the Fitness for Operational Requirements of Canadian Armed Forces Employment (FORCE), a field expedient fitness test designed to predict the physical requirements of completing common military tasks. Given that attaining this minimal physical fitness standard may not represent a challenge to some personnel, a fitness incentive program was requested by the chain of command to recognize and reward fitness over and above the minimal standard. At the same time, it was determined that the CAF would benefit from a measure of general health-related fitness, in addition to this measure of operational fitness. The resulting incentive program structure is based on gender and 8 age categories. The results on the 4 elements of the FORCE evaluation were converted to a point scale from which normative scores were derived, where the median score corresponds to the bronze level, and silver, gold, and platinum correspond to a score which is 1, 2, and 3 SDs above this median, respectively. A suite of rewards including merit board point toward promotions and recognition on the uniform and material rewards was developed. A separate group rewards program was also tabled, to recognize achievements in fitness at the unit level. For general fitness, oxygen capacity was derived from FORCE evaluation results and combined with a measure of abdominal circumference. Fitness categories were determined based on relative risks of mortality and morbidity for each age and gender group. Pilot testing of this entire program was performed with 624 participants to assess participants' reactions to the enhanced test, and also to verify logistical aspects of the electronic data capture, calculation, and transfer system. The newly dubbed fitness profile program was subsequently approved by the senior leadership of the CAF and is scheduled to begin a phased implementation in June 2015.

  20. A Quantitative Review of the Relationship between Person-Organization Fit and Behavioral Outcomes

    ERIC Educational Resources Information Center

    Hoffman, Brian J.; Woehr, David J.

    2006-01-01

    This paper extends the meta-analysis of Verquer, Beehr, and Wagner by providing a meta-analytic review of the relationship between person-organization fit (PO fit) and behavioral criteria (job performance, organizational citizenship behaviors, and turnover). Results indicate that PO fit is weakly to moderately related to each of these outcome…

  1. Individual Fit Testing of Hearing Protection Devices Based on Microphone in Real Ear.

    PubMed

    Biabani, Azam; Aliabadi, Mohsen; Golmohammadi, Rostam; Farhadian, Maryam

    2017-12-01

    Labeled noise reduction (NR) data presented by manufacturers are considered one of the main challenging issues for occupational experts in employing hearing protection devices (HPDs). This study aimed to determine the actual NR data of typical HPDs using the objective fit testing method with a microphone in real ear (MIRE) method. Five available commercially earmuff protectors were investigated in 30 workers exposed to reference noise source according to the standard method, ISO 11904-1. Personal attenuation rating (PAR) of the earmuffs was measured based on the MIRE method using a noise dosimeter (SVANTEK, model SV 102). The results showed that means of PAR of the earmuffs are from 49% to 86% of the nominal NR rating. The PAR values of earmuffs when a typical eyewear was worn differed statistically ( p < 0.05). It is revealed that a typical safety eyewear can reduce the mean of the PAR value by approximately 2.5 dB. The results also showed that measurements based on the MIRE method resulted in low variability. The variability in NR values between individuals, within individuals, and within earmuffs was not the statistically significant ( p > 0.05). This study could provide local individual fit data. Ergonomic aspects of the earmuffs and different levels of users experience and awareness can be considered the main factors affecting individual fitting compared with the laboratory condition for acquiring the labeled NR data. Based on the obtained fit testing results, the field application of MIRE can be employed for complementary studies in real workstations while workers perform their regular work duties.

  2. Assessment of auditory skills in 140 cochlear implant children using the EARS protocol.

    PubMed

    Sainz, Manuel; Skarzynski, Henryk; Allum, John H J; Helms, Jan; Rivas, Adriana; Martin, Jane; Zorowka, Patrick Georg; Phillips, Lucy; Delauney, Joseph; Brockmeyer, Steffi Johanna; Kompis, Martin; Korolewa, Inna; Albegger, Klaus; Zwirner, Petra; Van De Heyning, Paul; D'Haese, Patrick

    2003-01-01

    Auditory performance of cochlear implant (CI) children was assessed with the Listening Progress Profile (LiP) and the Monosyllabic-Trochee-Polysyllabic-Word Test (MTP) following the EARS protocol. Additionally, the 'initial drop' phenomenon, a recently reported decrease of auditory performance occurring immediately after first fitting, was investigated. Patients were 140 prelingually deafened children from various clinics and centers worldwide implanted with a MEDEL COMBI 40/40+. Analysis of LiP data showed a significant increase after 1 month of CI use compared to preoperative scores (p < 0.01). No initial decrease was observed with this test. Analysis of MTP data revealed a significant improvement of word recognition after 6 months (p < 0.01), with a significant temporary decrease after initial fitting (p < 0.01). With both tests, children's auditory skills improved up to 2 years. Amount of improvement was negatively correlated with age at implantation. Copyright 2003 S. Karger AG, Basel

  3. Top 10 Research Questions Related to Musculoskeletal Physical Fitness Testing in Children and Adolescents

    ERIC Educational Resources Information Center

    Plowman, Sharon Ann

    2014-01-01

    The purpose of this article is to bring attention to the 10 most pressing questions relevant to musculoskeletal physical fitness testing in children and adolescents. The goal is to stimulate research to answer these questions. The most pressing needs include establishing definitive links between valid, reliable, and feasible field test measures of…

  4. Evaluating Goodness-of-Fit Indexes for Testing Measurement Invariance.

    ERIC Educational Resources Information Center

    Cheung, Gordon W.; Rensvold, Roger B.

    2002-01-01

    Examined 20 goodness-of-fit indexes based on the minimum fit function using a simulation under the 2-group situation. Results support the use of the delta comparative fit index, delta Gamma hat, and delta McDonald's Noncentrality Index to evaluation measurement invariance. These three approaches are independent of model complexity and sample size.…

  5. Utah Regional Differences in Respirator Use and Fit Testing among Pesticide Applicators.

    PubMed

    Pate, Michael L; Beard, F Richard; Hall, Kelsey

    2017-01-26

    The purpose of this study was to determine regional differences within Utah in response to piloting a mobile respirator training and fit assessment program for pesticide applicators. The objectives were to describe worker perceptions of respirator use and training experiences. Pilot trainings were offered in two southern counties and two northern counties of Utah. A total of 141 individuals completed the post-training questionnaire regarding use and fit testing experience with respirators as well as perceptions of the benefits to protecting respiratory health. The majority of respondents were male (95.7%, f = 112). The proportion of participants in the southern counties who had respirator training experience (61.0%, f = 25) was not significantly higher (2 = 3.763, df = 1, p = 0.05) than the proportion of participants in the northern counties (43.0%, f = 43). Three-fourths (73.5%, f = 72) of participants in the northern counties agreed that they expect to wear a respirator in dusty conditions, while two-thirds (61.0%, f = 25) of participants in the southern counties agreed that they expect to wear a respirator in dusty conditions. The results indicated that more training should be done to improve perceptions and beliefs about using respirators. A high priority for this population will be identification of comfortable respirator options as well as communicating the importance of proper fit testing. Copyright© by the American Society of Agricultural Engineers.

  6. A comparison of battery testing protocols: Those used by the U.S. advanced battery consortium and those used in China

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robertson, David C.; Christophersen, Jon P.; Bennett, Taylor

    Two testing protocols, QC/T 743 and those used by the U.S. Advanced Battery Consortium (USABC), were compared using cells based on LiFePO4/graphite chemistry. Differences in the protocols directly affected the data and the performance decline mechanisms deduced from the data. A change in capacity fade mechanism from linear-with-time to t1/2 was observed when the power density measurement was included in the QC/T 743 testing. The rate of resistance increase was linear with time using both protocols. Overall, the testing protocols produced very similar data when the testing conditions and metrics used to define performance were similar. The choice of depthmore » of discharge and pulse width had a direct effect on estimated cell life. At greater percent depth of discharge (%DOD) and pulse width, the estimated life was shorter that at lower %DOD and shorter pulse width. This indicates that cells which were at the end of life based on the USABC protocol were not at end of life based on the QC/T 743 protocol by a large margin.« less

  7. Development of Test Protocols for International Space Station Particulate Filters

    NASA Technical Reports Server (NTRS)

    Vijayakumar, R.; Green, Robert D.; Agui, Juan H.

    2015-01-01

    Air quality control on the International Space Station (ISS) is a vital requirement for maintaining a clean environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of gravitational settling. The ISS Environmental Control and Life Support System (ECLSS) uses a filtration system that has been in use for over 14 years and has proven to meet this challenge. The heart of this system is a traditional High-Efficiency Particulate Air (HEPA) filter configured to interface with the rest of the life support elements and provide effective cabin filtration. The filter element for this system has a non-standard cross-section with a length-to-width ratio (LW) of 6.6. A filter test setup was designed and built to meet industry testing standards. A CFD analysis was performed to initially determine the optimal duct geometry and flow configuration. Both a screen and flow straighter were added to the test duct design to improve flow uniformity and face velocity profiles were subsequently measured to confirm. Flow quality and aerosol mixing assessments show that the duct flow is satisfactory for the intended leak testing. Preliminary leak testing was performed on two different ISS filters, one with known perforations and one with limited use, and results confirmed that the testing methods and photometer instrument are sensitive enough to detect and locate compromised sections of an ISS BFE.Given the engineering constraints in designing spacecraft life support systems, it is anticipated that non-industry standard filters will be required in future designs. This work is focused on developing test protocols for testing the ISS BFE filters, but the methodology is general enough to be extended to other present and future spacecraft filters. These techniques for characterizing the test duct and perform leak testing

  8. Measuring fit of sequence data to phylogenetic model: gain of power using marginal tests.

    PubMed

    Waddell, Peter J; Ota, Rissa; Penny, David

    2009-10-01

    Testing fit of data to model is fundamentally important to any science, but publications in the field of phylogenetics rarely do this. Such analyses discard fundamental aspects of science as prescribed by Karl Popper. Indeed, not without cause, Popper (Unended quest: an intellectual autobiography. Fontana, London, 1976) once argued that evolutionary biology was unscientific as its hypotheses were untestable. Here we trace developments in assessing fit from Penny et al. (Nature 297:197-200, 1982) to the present. We compare the general log-likelihood ratio (the G or G (2) statistic) statistic between the evolutionary tree model and the multinomial model with that of marginalized tests applied to an alignment (using placental mammal coding sequence data). It is seen that the most general test does not reject the fit of data to model (P approximately 0.5), but the marginalized tests do. Tests on pairwise frequency (F) matrices, strongly (P < 0.001) reject the most general phylogenetic (GTR) models commonly in use. It is also clear (P < 0.01) that the sequences are not stationary in their nucleotide composition. Deviations from stationarity and homogeneity seem to be unevenly distributed amongst taxa; not necessarily those expected from examining other regions of the genome. By marginalizing the 4( t ) patterns of the i.i.d. model to observed and expected parsimony counts, that is, from constant sites, to singletons, to parsimony informative characters of a minimum possible length, then the likelihood ratio test regains power, and it too rejects the evolutionary model with P < 0.001. Given such behavior over relatively recent evolutionary time, readers in general should maintain a healthy skepticism of results, as the scale of the systematic errors in published trees may really be far larger than the analytical methods (e.g., bootstrap) report.

  9. Gray Matter Correlates of Fluid, Crystallized, and Spatial Intelligence: Testing the P-FIT Model

    ERIC Educational Resources Information Center

    Colom, Roberto; Haier, Richard J.; Head, Kevin; Alvarez-Linera, Juan; Quiroga, Maria Angeles; Shih, Pei Chun; Jung, Rex E.

    2009-01-01

    The parieto-frontal integration theory (P-FIT) nominates several areas distributed throughout the brain as relevant for intelligence. This theory was derived from previously published studies using a variety of both imaging methods and tests of cognitive ability. Here we test this theory in a new sample of young healthy adults (N = 100) using a…

  10. Sensitivity test of derivative matrix isopotential synchronous fluorimetry and least squares fitting methods.

    PubMed

    Makkai, Géza; Buzády, Andrea; Erostyák, János

    2010-01-01

    Determination of concentrations of spectrally overlapping compounds has special difficulties. Several methods are available to calculate the constituents' concentrations in moderately complex mixtures. A method which can provide information about spectrally hidden components in mixtures is very useful. Two methods powerful in resolving spectral components are compared in this paper. The first method tested is the Derivative Matrix Isopotential Synchronous Fluorimetry (DMISF). It is based on derivative analysis of MISF spectra, which are constructed using isopotential trajectories in the Excitation-Emission Matrix (EEM) of background solution. For DMISF method, a mathematical routine fitting the 3D data of EEMs was developed. The other method tested uses classical Least Squares Fitting (LSF) algorithm, wherein Rayleigh- and Raman-scattering bands may lead to complications. Both methods give excellent sensitivity and have advantages against each other. Detection limits of DMISF and LSF have been determined at very different concentration and noise levels.

  11. Quality control for quantitative PCR based on amplification compatibility test.

    PubMed

    Tichopad, Ales; Bar, Tzachi; Pecen, Ladislav; Kitchen, Robert R; Kubista, Mikael; Pfaffl, Michael W

    2010-04-01

    Quantitative qPCR is a routinely used method for the accurate quantification of nucleic acids. Yet it may generate erroneous results if the amplification process is obscured by inhibition or generation of aberrant side-products such as primer dimers. Several methods have been established to control for pre-processing performance that rely on the introduction of a co-amplified reference sequence, however there is currently no method to allow for reliable control of the amplification process without directly modifying the sample mix. Herein we present a statistical approach based on multivariate analysis of the amplification response data generated in real-time. The amplification trajectory in its most resolved and dynamic phase is fitted with a suitable model. Two parameters of this model, related to amplification efficiency, are then used for calculation of the Z-score statistics. Each studied sample is compared to a predefined reference set of reactions, typically calibration reactions. A probabilistic decision for each individual Z-score is then used to identify the majority of inhibited reactions in our experiments. We compare this approach to univariate methods using only the sample specific amplification efficiency as reporter of the compatibility. We demonstrate improved identification performance using the multivariate approach compared to the univariate approach. Finally we stress that the performance of the amplification compatibility test as a quality control procedure depends on the quality of the reference set. Copyright 2010 Elsevier Inc. All rights reserved.

  12. Semi-Quantitative Scoring of an Immunochromatographic Test for Circulating Filarial Antigen

    PubMed Central

    Chesnais, Cédric B.; Missamou, François; Pion, Sébastien D. S.; Bopda, Jean; Louya, Frédéric; Majewski, Andrew C.; Weil, Gary J.; Boussinesq, Michel

    2013-01-01

    The value of a semi-quantitative scoring of the filarial antigen test (Binax Now Filariasis card test, ICT) results was evaluated during a field survey in the Republic of Congo. One hundred and thirty-four (134) of 774 tests (17.3%) were clearly positive and were scored 1, 2, or 3; and 11 (1.4%) had questionable results. Wuchereria bancrofti microfilariae (mf) were detected in 41 of those 133 individuals with an ICT test score ≥ 1 who also had a night blood smear; none of the 11 individuals with questionable ICT results harbored night mf. Cuzick's test showed a significant trend for higher microfilarial densities in groups with higher ICT scores (P < 0.001). The ICT scores were also significantly correlated with blood mf counts. Because filarial antigen levels provide an indication of adult worm infection intensity, our results suggest that semi-quantitative reading of the ICT may be useful for grading the intensity of filarial infections in individuals and populations. PMID:24019435

  13. A Text Analysis of the Marine Corps Fitness Report

    DTIC Science & Technology

    2017-06-01

    difficulty in quantitatively analyzing textual. The study pulls 835 anonymous and non-attributable surveys between 2005 and 2009 from the Center for... quantitative assessments of performance. 14. SUBJECT TERMS natural language processing, fitness reports, computational linguistics, manpower 15. NUMBER...Corps provide word-picture guidance to distinguish talented Marines and promote conformity in issuing quantitative assessments of performance. vi

  14. Role of self-reported individual differences in preference for and tolerance of exercise intensity in fitness testing performance.

    PubMed

    Hall, Eric E; Petruzzello, Steven J; Ekkekakis, Panteleimon; Miller, Paul C; Bixby, Walter R

    2014-09-01

    Performance in fitness tests could depend on factors beyond the bioenergetic and skeletomuscular systems, such as individual differences in preference for and tolerance of different levels of exercise-induced somatosensory stimulation. Although such individual-difference variables could play a role in exercise testing and prescription, they have been understudied. The purpose of these studies was to examine the relationships of self-reported preference for and tolerance of exercise intensity with performance in fitness tests. Participants in study I were 516 men and women volunteers from a campus community, and participants in study II were 42 men recruit firefighters undergoing a 6-week training program. Both the Preference and Tolerance scores exhibited significant relationships with performance in several fitness tests and with body composition and physical activity participation. Preference and Tolerance did not change after the training program in study II, despite improvements in objective and perceived fitness, supporting their conceptualization as dispositional traits. Preference and Tolerance scores could be useful not only in ameliorating the current understanding of the determinants of physical performance, but also in personalizing exercise prescriptions and, thus, delivering exercise experiences that are more pleasant, tolerable, and sustainable.

  15. A Nonparametric Approach for Assessing Goodness-of-Fit of IRT Models in a Mixed Format Test

    ERIC Educational Resources Information Center

    Liang, Tie; Wells, Craig S.

    2015-01-01

    Investigating the fit of a parametric model plays a vital role in validating an item response theory (IRT) model. An area that has received little attention is the assessment of multiple IRT models used in a mixed-format test. The present study extends the nonparametric approach, proposed by Douglas and Cohen (2001), to assess model fit of three…

  16. Kernels, Degrees of Freedom, and Power Properties of Quadratic Distance Goodness-of-Fit Tests

    PubMed Central

    Lindsay, Bruce G.; Markatou, Marianthi; Ray, Surajit

    2014-01-01

    In this article, we study the power properties of quadratic-distance-based goodness-of-fit tests. First, we introduce the concept of a root kernel and discuss the considerations that enter the selection of this kernel. We derive an easy to use normal approximation to the power of quadratic distance goodness-of-fit tests and base the construction of a noncentrality index, an analogue of the traditional noncentrality parameter, on it. This leads to a method akin to the Neyman-Pearson lemma for constructing optimal kernels for specific alternatives. We then introduce a midpower analysis as a device for choosing optimal degrees of freedom for a family of alternatives of interest. Finally, we introduce a new diffusion kernel, called the Pearson-normal kernel, and study the extent to which the normal approximation to the power of tests based on this kernel is valid. Supplementary materials for this article are available online. PMID:24764609

  17. Feasibility and Reliability of Tests Measuring Health-Related Physical Fitness in Children with Moderate to Severe Levels of Intellectual Disability

    ERIC Educational Resources Information Center

    Wouters, Marieke; van der Zanden, Anna M.; Evenhuis, Heleen M.; Hilgenkamp, Thessa I. M.

    2017-01-01

    Physical fitness is an important marker for health. In this study we investigated the feasibility and reliability of health-related physical fitness tests in children with moderate to severe levels of intellectual disability. Thirty-nine children (2-18 yrs) performed tests for muscular strength and endurance, the modified 6-minute walk test (6mwt)…

  18. Validity of the 30-15 Intermittent Fitness Test in Subelite Female Athletes.

    PubMed

    Bruce, Lyndell M; Moule, Simon J

    2017-11-01

    Bruce, LM and Moule, SJ. Validity of the 30-15 intermittent fitness test in subelite female athletes. J Strength Cond Res 31(11): 3077-3082, 2017-The purpose of this study was to assess the suitability of the 30-15 Intermittent Fitness Test (IFT) as a test in netball using female athletes. Twenty-six female subelite netballers (mean age = 19.7 ± 4.6 years, mean height = 176.0 ± 6.1 cm, mean body mass = 69.7 ± 9.3 kg) completed the yo-yo intermittent recovery test level 1 (yo-yo IRT1) and the 30-15 IFT. Participants performed both assessments 1 week apart before the intervention and both tests 1 week apart after the training intervention (for a total of 4 testing sessions). A 6-week training intervention occurred between the test occasions. Pearson's correlations revealed significant very strong relationships between the 30-15 IFT and yo-yo IRT on both test occasions (test occasion 1: r = 0.71, p = 0.003 [95% confidence interval {CI} 0.35-0.89], magnitude of effect, most likely; test occasion 2: r = 0.72, p = 0.001 [95% CI: 0.42-0.88], magnitude of effect, most likely). Repeated-measures analysis of variances examining the effect of position on performance changes revealed main effects for test occasion and a position × test occasion interaction for both the 30-15 IFT and the yo-yo IRT1 (30-15 IFT: test occasion [F(1,14) = 28.68, p = 0.001, ηp = 0.67], position × test occasion interaction [F(2,14) = 9.38, p = 0.003, ηp = 0.57]; yo-yo IRT1: test occasion [F(1,15) = 11.72, p = 0.004, ηp = 0.44], position × test occasion interaction [F(2,15) = 9.96, p = 0.002, ηp = 0.57]). Results show that the 30-15 IFT is a suitable test for female netballers as it was able to detect improvements in performance after a training intervention, in addition to having a very strong significant relationship with the yo-yo IRT1.

  19. Assessing child belt fit, volume II : effect of restraint configuration, booster seat designs, seating procedure, and belt fit on the dynamic response of the hybrid III 10-year-old ATD in sled tests.

    DOT National Transportation Integrated Search

    2008-09-01

    A total of 49 dynamic sled tests were performed with the Hybrid III 10YO to examine issues relating to child belt fit. The goals of these tests were to evaluate ATD response to realistic belt geometries and belt fit, develop methods for accurate, rep...

  20. A Sport Education Fitness Season's Impact on Students' Fitness Levels, Knowledge, and In-Class Physical Activity.

    PubMed

    Ward, Jeffery Kurt; Hastie, Peter A; Wadsworth, Danielle D; Foote, Shelby; Brock, Sheri J; Hollett, Nikki

    2017-09-01

    The purpose of this study was to determine the extent to which a sport education season of fitness could provide students with recommended levels of in-class moderate-to-vigorous physical activity (MVPA) while also increasing students' fitness knowledge and fitness achievement. One hundred and sixty-six 5th-grade students (76 boys, 90 girls) participated in a 20-lesson season called "CrossFit Challenge" during a 4-week period. The Progressive Aerobic Cardiovascular Endurance Run, push-ups, and curl-ups tests of the FITNESSGRAM® were used to assess fitness at pretest and posttest, while fitness knowledge was assessed through a validated, grade-appropriate test of health-related fitness knowledge (HRF). Physical activity was measured with Actigraph GT3X triaxial accelerometers. Results indicated a significant time effect for all fitness tests and the knowledge test. Across the entire season, the students spent an average of 54.5% of lesson time engaged in MVPA, irrespective of the type of lesson (instruction, free practice, or competition). The results suggest that configuring the key principles of sport education within a unit of fitness is an efficient model for providing students with the opportunity to improve fitness skill and HRF knowledge while attaining recommended levels of MVPA.

  1. International Standards and Reference Materials for Quantitative Molecular Infectious Disease Testing

    PubMed Central

    Madej, Roberta M.; Davis, Jack; Holden, Marcia J.; Kwang, Stan; Labourier, Emmanuel; Schneider, George J.

    2010-01-01

    The utility of quantitative molecular diagnostics for patient management depends on the ability to relate patient results to prior results or to absolute values in clinical practice guidelines. To do this, those results need to be comparable across time and methods, either by producing the same value across methods and test versions or by using reliable and stable conversions. Universally available standards and reference materials specific to quantitative molecular technologies are critical to this process but are few in number. This review describes recent history in the establishment of international standards for nucleic acid test development, organizations involved in current efforts, and future issues and initiatives. PMID:20075208

  2. Relationships Among Goal Contents, Exercise Motivations, Physical Activity, and Aerobic Fitness in University Physical Education Courses.

    PubMed

    Sibley, Benjamin A; Bergman, Shawn M

    2016-04-01

    The current research examined the relationships among exercise goal contents, behavioral regulation, physical activity, and aerobic fitness within the context of eight-week university physical education courses. Participants were undergraduate students (M age = 20.2 year, SD = 2.3) enrolled in activity courses (N = 461) during the 2010 Fall semester. At pretest, participants completed a demographic survey, Behavioral Regulation in Exercise Questionnaire and the Goal Contents in Exercise Questionnaire. At eight-week posttest, participants completed the Physical Activity Questionnaire for Adults and the PACER aerobic fitness test. Relative intrinsic goal content was found to predict physical activity indirectly and aerobic fitness via behavioral regulation. Specific goal contents related to health management and skill development were found to predict physical activity and aerobic fitness via a fully mediated path through identified and intrinsic regulation. Results supported the efficacy of goal contents and self-determination theory in describing physical activity behavior and fitness. Examining specific types of goal contents and behavioral regulations revealed relationships that were masked by the utilization of omnibus scoring protocols. © The Author(s) 2016.

  3. Genotypic tropism testing by massively parallel sequencing: qualitative and quantitative analysis.

    PubMed

    Däumer, Martin; Kaiser, Rolf; Klein, Rolf; Lengauer, Thomas; Thiele, Bernhard; Thielen, Alexander

    2011-05-13

    Inferring viral tropism from genotype is a fast and inexpensive alternative to phenotypic testing. While being highly predictive when performed on clonal samples, sensitivity of predicting CXCR4-using (X4) variants drops substantially in clinical isolates. This is mainly attributed to minor variants not detected by standard bulk-sequencing. Massively parallel sequencing (MPS) detects single clones thereby being much more sensitive. Using this technology we wanted to improve genotypic prediction of coreceptor usage. Plasma samples from 55 antiretroviral-treated patients tested for coreceptor usage with the Monogram Trofile Assay were sequenced with standard population-based approaches. Fourteen of these samples were selected for further analysis with MPS. Tropism was predicted from each sequence with geno2pheno[coreceptor]. Prediction based on bulk-sequencing yielded 59.1% sensitivity and 90.9% specificity compared to the trofile assay. With MPS, 7600 reads were generated on average per isolate. Minorities of sequences with high confidence in CXCR4-usage were found in all samples, irrespective of phenotype. When using the default false-positive-rate of geno2pheno[coreceptor] (10%), and defining a minority cutoff of 5%, the results were concordant in all but one isolate. The combination of MPS and coreceptor usage prediction results in a fast and accurate alternative to phenotypic assays. The detection of X4-viruses in all isolates suggests that coreceptor usage as well as fitness of minorities is important for therapy outcome. The high sensitivity of this technology in combination with a quantitative description of the viral population may allow implementing meaningful cutoffs for predicting response to CCR5-antagonists in the presence of X4-minorities.

  4. A Rigorous Test of the Fit of the Circumplex Model to Big Five Personality Data: Theoretical and Methodological Issues and Two Large Sample Empirical Tests.

    PubMed

    DeGeest, David Scott; Schmidt, Frank

    2015-01-01

    Our objective was to apply the rigorous test developed by Browne (1992) to determine whether the circumplex model fits Big Five personality data. This test has yet to be applied to personality data. Another objective was to determine whether blended items explained correlations among the Big Five traits. We used two working adult samples, the Eugene-Springfield Community Sample and the Professional Worker Career Experience Survey. Fit to the circumplex was tested via Browne's (1992) procedure. Circumplexes were graphed to identify items with loadings on multiple traits (blended items), and to determine whether removing these items changed five-factor model (FFM) trait intercorrelations. In both samples, the circumplex structure fit the FFM traits well. Each sample had items with dual-factor loadings (8 items in the first sample, 21 in the second). Removing blended items had little effect on construct-level intercorrelations among FFM traits. We conclude that rigorous tests show that the fit of personality data to the circumplex model is good. This finding means the circumplex model is competitive with the factor model in understanding the organization of personality traits. The circumplex structure also provides a theoretically and empirically sound rationale for evaluating intercorrelations among FFM traits. Even after eliminating blended items, FFM personality traits remained correlated.

  5. Adolescent Girls' Preferences Pertaining to Cardiovascular Fitness Testing: A Comparison between the One-Mile Run and PACER Tests

    ERIC Educational Resources Information Center

    Wilkinson, Carol; Brown, Lanell; Graser, Sue Vincent; Pennington, Todd R.

    2012-01-01

    Many adolescent girls are not participating in the recommended levels of physical activity (PA) and are at risk for unhealthy lifestyles (U.S. Department of Health and Human Services, 2008). Helping girls understand the importance of PA and giving them positive experiences in physical education classes, including fitness testing, may help to…

  6. Impact of body composition on performance in fitness tests among personnel of the Croatian navy.

    PubMed

    Sporis, Goran; Jukić, Igor; Bok, Daniel; Vuleta, Dinko; Harasin, Drazen

    2011-06-01

    The purpose of this study was to determine the impact of body weight on fitness tests among the personnel of the Croatian navy. Forty two naval personnel (age 27 +/- 4.1 years; body mass 86.2 +/- 4.9 kg; height 184.6 +/- 7.4 cm; body fat percentage 17.3 +/- 5.2) participated in this study. In order to evaluate the fitness of the naval servicemen, we applied a testing procedure that included measurements of 7 fitness tests and 15 body anthropometric tests. A negative correlation was found between the body fat percentage and all the analyzed sprint tests and three anaerobic power tests (r), SP5 (r = -0.42), SP10 (r = -0.51), SP20 (r = -0.53), SJ (r = -0.45), CM (r = -0.57), SLJ (r = -0.67). Also a negative correlation was found between the body fat percentage and VO2(max) (r = -0.44). A positive correlation was found between the sprint test and the power performance test and thigh and calf girth. Spiriting ability is influenced by the strength of a person. This is one of the reasons why we found a positive correlation between the sprint test (SP5, SP10 and SP20) and thigh and calf girth. In this study we found a negative correlation between body fat percentages and all the sprint tests and three anaerobic power tests and VO2(max). The ectomorph somatotypes have positive correlations with all variables. The mesomorph somatotypes have the greatest positive correlations with all variables. The endomorph somatotypes have negative correlations with all variables. According to the body composition of Croatian naval servicemen we can conclude that they need a sufficient level of strength and endurance for everyday tasks. The effectiveness of a weight-management program is determined by the success of the participants in losing the necessary amount of weight and being able to maintain that weight loss. This requires long-term tracking of these individuals in a naval environment.

  7. Reproducibility of a peripheral quantitative computed tomography scan protocol to measure the material properties of the second metatarsal.

    PubMed

    Chaplais, Elodie; Greene, David; Hood, Anita; Telfer, Scott; du Toit, Verona; Singh-Grewal, Davinder; Burns, Joshua; Rome, Keith; Schiferl, Daniel J; Hendry, Gordon J

    2014-07-19

    Peripheral quantitative computed tomography (pQCT) is an established technology that allows for the measurement of the material properties of bone. Alterations to bone architecture are associated with an increased risk of fracture. Further pQCT research is necessary to identify regions of interest that are prone to fracture risk in people with chronic diseases. The second metatarsal is a common site for the development of insufficiency fractures, and as such the aim of this study was to assess the reproducibility of a novel scanning protocol of the second metatarsal using pQCT. Eleven embalmed cadaveric leg specimens were scanned six times; three times with and without repositioning. Each foot was positioned on a custom-designed acrylic foot plate to permit unimpeded scans of the region of interest. Sixty-six scans were obtained at 15% (distal) and 50% (mid shaft) of the second metatarsal. Voxel size and scan speed were reduced to 0.40 mm and 25 mm.sec(-1). The reference line was positioned at the most distal portion of the 2(nd) metatarsal. Repeated measurements of six key variables related to bone properties were subject to reproducibility testing. Data were log transformed and reproducibility of scans were assessed using intraclass correlation coefficients (ICC) and coefficients of variation (CV%). Reproducibility of the measurements without repositioning were estimated as: trabecular area (ICC 0.95; CV% 2.4), trabecular density (ICC 0.98; CV% 3.0), Strength Strain Index (SSI) - distal (ICC 0.99; CV% 5.6), cortical area (ICC 1.0; CV% 1.5), cortical density (ICC 0.99; CV% 0.1), SSI - mid shaft (ICC 1.0; CV% 2.4). Reproducibility of the measurements after repositioning were estimated as: trabecular area (ICC 0.96; CV% 2.4), trabecular density (ICC 0.98; CV% 2.8), SSI - distal (ICC 1.0; CV% 3.5), cortical area (ICC 0.99; CV%2.4), cortical density (ICC 0.98; CV% 0.8), SSI - mid shaft (ICC 0.99; CV% 3.2). The scanning protocol generated excellent reproducibility for

  8. Reproducibility of a peripheral quantitative computed tomography scan protocol to measure the material properties of the second metatarsal

    PubMed Central

    2014-01-01

    Background Peripheral quantitative computed tomography (pQCT) is an established technology that allows for the measurement of the material properties of bone. Alterations to bone architecture are associated with an increased risk of fracture. Further pQCT research is necessary to identify regions of interest that are prone to fracture risk in people with chronic diseases. The second metatarsal is a common site for the development of insufficiency fractures, and as such the aim of this study was to assess the reproducibility of a novel scanning protocol of the second metatarsal using pQCT. Methods Eleven embalmed cadaveric leg specimens were scanned six times; three times with and without repositioning. Each foot was positioned on a custom-designed acrylic foot plate to permit unimpeded scans of the region of interest. Sixty-six scans were obtained at 15% (distal) and 50% (mid shaft) of the second metatarsal. Voxel size and scan speed were reduced to 0.40 mm and 25 mm.sec-1. The reference line was positioned at the most distal portion of the 2nd metatarsal. Repeated measurements of six key variables related to bone properties were subject to reproducibility testing. Data were log transformed and reproducibility of scans were assessed using intraclass correlation coefficients (ICC) and coefficients of variation (CV%). Results Reproducibility of the measurements without repositioning were estimated as: trabecular area (ICC 0.95; CV% 2.4), trabecular density (ICC 0.98; CV% 3.0), Strength Strain Index (SSI) - distal (ICC 0.99; CV% 5.6), cortical area (ICC 1.0; CV% 1.5), cortical density (ICC 0.99; CV% 0.1), SSI – mid shaft (ICC 1.0; CV% 2.4). Reproducibility of the measurements after repositioning were estimated as: trabecular area (ICC 0.96; CV% 2.4), trabecular density (ICC 0.98; CV% 2.8), SSI - distal (ICC 1.0; CV% 3.5), cortical area (ICC 0.99; CV%2.4), cortical density (ICC 0.98; CV% 0.8), SSI – mid shaft (ICC 0.99; CV% 3.2). Conclusions The scanning protocol

  9. Workplace support, discrimination, and person-organization fit: tests of the theory of work adjustment with LGB individuals.

    PubMed

    Velez, Brandon L; Moradi, Bonnie

    2012-07-01

    The present study explored the links of 2 workplace contextual variables--perceptions of workplace heterosexist discrimination and lesbian, gay, and bisexual (LGB)-supportive climates--with job satisfaction and turnover intentions in a sample of LGB employees. An extension of the theory of work adjustment (TWA) was used as the conceptual framework for the study; as such, perceived person-organization (P-O) fit was tested as a mediator of the relations between the workplace contextual variables and job outcomes. Data were analyzed from 326 LGB employees. Zero-order correlations indicated that perceptions of workplace heterosexist discrimination and LGB-supportive climates were correlated in expected directions with P-O fit, job satisfaction, and turnover intentions. Structural equation modeling (SEM) was used to compare multiple alternative measurement models evaluating the discriminant validity of the 2 workplace contextual variables relative to one another, and the 3 TWA job variables relative to one another; SEM was also used to test the hypothesized mediation model. Comparisons of multiple alternative measurement models supported the construct distinctiveness of the variables of interest. The test of the hypothesized structural model revealed that only LGB-supportive climates (and not workplace heterosexist discrimination) had a unique direct positive link with P-O fit and, through the mediating role of P-O fit, had significant indirect positive and negative relations with job satisfaction and turnover intentions, respectively. Moreover, P-O fit had a significant indirect negative link with turnover intentions through job satisfaction.

  10. Between-Day Reliability and Usefulness of a Fitness Testing Battery in Youth Sport Athletes: Reference Data for Practitioners

    ERIC Educational Resources Information Center

    Sawczuk, Thomas; Jones, Ben; Scantlebury, Sean; Weakley, Jonathan; Read, Dale; Costello, Nessan; Darrall-Jones, Joshua David; Stokes, Keith; Till, Kevin

    2018-01-01

    This study aimed to evaluate the between-day reliability and usefulness of a fitness testing battery in a group of youth sport athletes. Fifty-nine youth sport athletes (age = 17.3 ± 0.7 years) undertook a fitness testing battery including the isometric mid-thigh pull, counter-movement jump, 5-40 m sprint splits, and the 5-0-5 change of direction…

  11. Strain Gage Load Calibration of the Wing Interface Fittings for the Adaptive Compliant Trailing Edge Flap Flight Test

    NASA Technical Reports Server (NTRS)

    Miller, Eric J.; Holguin, Andrew C.; Cruz, Josue; Lokos, William A.

    2014-01-01

    The safety-of-flight parameters for the Adaptive Compliant Trailing Edge (ACTE) flap experiment require that flap-to-wing interface loads be sensed and monitored in real time to ensure that the structural load limits of the wing are not exceeded. This paper discusses the strain gage load calibration testing and load equation derivation methodology for the ACTE interface fittings. Both the left and right wing flap interfaces were monitored; each contained four uniquely designed and instrumented flap interface fittings. The interface hardware design and instrumentation layout are discussed. Twenty-one applied test load cases were developed using the predicted in-flight loads. Pre-test predictions of strain gage responses were produced using finite element method models of the interface fittings. Predicted and measured test strains are presented. A load testing rig and three hydraulic jacks were used to apply combinations of shear, bending, and axial loads to the interface fittings. Hardware deflections under load were measured using photogrammetry and transducers. Due to deflections in the interface fitting hardware and test rig, finite element model techniques were used to calculate the reaction loads throughout the applied load range, taking into account the elastically-deformed geometry. The primary load equations were selected based on multiple calibration metrics. An independent set of validation cases was used to validate each derived equation. The 2-sigma residual errors for the shear loads were less than eight percent of the full-scale calibration load; the 2-sigma residual errors for the bending moment loads were less than three percent of the full-scale calibration load. The derived load equations for shear, bending, and axial loads are presented, with the calculated errors for both the calibration cases and the independent validation load cases.

  12. Semi Quantitative MALDI TOF for Antimicrobial Susceptibility Testing in Staphylococcus aureus

    DTIC Science & Technology

    2017-08-31

    Semi- quantitative MALDI-TOF for antimicrobial susceptibility testing in Staphylococcus 1 aureus 2 3 4 Tucker Maxson,a Cheryl L. Taylor-Howell,a...Timothy D. Minoguea# 5 6 Diagnostic Systems Division, United States Army Medical Research Institute of Infectious 7 Disease, Fort Detrick, MD...USAa 8 9 Running Title: Quantitative MALDI for AST in S. aureus 10 #Address correspondence to Timothy D. Minogue, timothy.d.minogue.civ@mail.mil

  13. PACIFIC NORTHWEST SIDE-BY-SIDE PROTOCOL COMPARISON TEST

    EPA Science Inventory

    Eleven state, tribal, and federal agencies participated during summer 2005 in a side-by-side comparison of protocols used to measure common in-stream physical attributes to help determine which protocols are best for determining status and trend of stream/watershed condition. Th...

  14. Reinventing the ames test as a quantitative lab that connects classical and molecular genetics.

    PubMed

    Goodson-Gregg, Nathan; De Stasio, Elizabeth A

    2009-01-01

    While many institutions use a version of the Ames test in the undergraduate genetics laboratory, students typically are not exposed to techniques or procedures beyond qualitative analysis of phenotypic reversion, thereby seriously limiting the scope of learning. We have extended the Ames test to include both quantitative analysis of reversion frequency and molecular analysis of revertant gene sequences. By giving students a role in designing their quantitative methods and analyses, students practice and apply quantitative skills. To help students connect classical and molecular genetic concepts and techniques, we report here procedures for characterizing the molecular lesions that confer a revertant phenotype. We suggest undertaking reversion of both missense and frameshift mutants to allow a more sophisticated molecular genetic analysis. These modifications and additions broaden the educational content of the traditional Ames test teaching laboratory, while simultaneously enhancing students' skills in experimental design, quantitative analysis, and data interpretation.

  15. Preliminary research on eddy current bobbin quantitative test for heat exchange tube in nuclear power plant

    NASA Astrophysics Data System (ADS)

    Qi, Pan; Shao, Wenbin; Liao, Shusheng

    2016-02-01

    For quantitative defects detection research on heat transfer tube in nuclear power plants (NPP), two parts of work are carried out based on the crack as the main research objects. (1) Production optimization of calibration tube. Firstly, ASME, RSEM and homemade crack calibration tubes are applied to quantitatively analyze the defects depth on other designed crack test tubes, and then the judgment with quantitative results under crack calibration tube with more accuracy is given. Base on that, weight analysis of influence factors for crack depth quantitative test such as crack orientation, length, volume and so on can be undertaken, which will optimize manufacture technology of calibration tubes. (2) Quantitative optimization of crack depth. Neural network model with multi-calibration curve adopted to optimize natural crack test depth generated in in-service tubes shows preliminary ability to improve quantitative accuracy.

  16. Echo-Planar Imaging Based J-Resolved Spectroscopic Imaging for Improved Metabolite Detection in Prostate Cancer

    DTIC Science & Technology

    2012-10-01

    parameters using the phantom (Months 6-12). Accomplished during September 29, 2011-October 28 2012: The sequence was tested using a prostate phantom...mI, Glu, Gln, sI, phosphoethanolamine and lactate using a GAMMA C++ library. Prostate metabolite quantitation has been tested using the ProFit...using phantom solutions containing metabolites and corn oil, the protocol has been successfully tested in healthy males, and malignant and BPH

  17. Short-Term Effects of Different Loading Schemes in Fitness-Related Resistance Training.

    PubMed

    Eifler, Christoph

    2016-07-01

    Eifler, C. Short-term effects of different loading schemes in fitness-related resistance training. J Strength Cond Res 30(7): 1880-1889, 2016-The purpose of this investigation was to analyze the short-term effects of different loading schemes in fitness-related resistance training and to identify the most effective loading method for advanced recreational athletes. The investigation was designed as a longitudinal field-test study. Two hundred healthy mature subjects with at least 12 months' experience in resistance training were randomized in 4 samples of 50 subjects each. Gender distribution was homogenous in all samples. Training effects were quantified by 10 repetition maximum (10RM) and 1 repetition maximum (1RM) testing (pre-post-test design). Over a period of 6 weeks, a standardized resistance training protocol with 3 training sessions per week was realized. Testing and training included 8 resistance training exercises in a standardized order. The following loading schemes were randomly matched to each sample: constant load (CL) with constant volume of repetitions, increasing load (IL) with decreasing volume of repetitions, decreasing load (DL) with increasing volume of repetitions, daily changing load (DCL), and volume of repetitions. For all loading schemes, significant strength gains (p < 0.001) could be noted for all resistance training exercises and both dependent variables (10RM, 1RM). In all cases, DCL obtained significantly higher strength gains (p < 0.001) than CL, IL, and DL. There were no significant differences in strength gains between CL, IL, and DL. The present data indicate that resistance training following DCL is more effective for advanced recreational athletes than CL, IL, or DL. Considering that DCL is widely unknown in fitness-related resistance training, the present data indicate, there is potential for improving resistance training in commercial fitness clubs.

  18. High-sensitivity stable-isotope probing by a quantitative terminal restriction fragment length polymorphism protocol.

    PubMed

    Andeer, Peter; Strand, Stuart E; Stahl, David A

    2012-01-01

    Stable-isotope probing (SIP) has proved a valuable cultivation-independent tool for linking specific microbial populations to selected functions in various natural and engineered systems. However, application of SIP to microbial populations with relatively minor buoyant density increases, such as populations that utilize compounds as a nitrogen source, results in reduced resolution of labeled populations. We therefore developed a tandem quantitative PCR (qPCR)-TRFLP (terminal restriction fragment length polymorphism) protocol that improves resolution of detection by quantifying specific taxonomic groups in gradient fractions. This method combines well-controlled amplification with TRFLP analysis to quantify relative taxon abundance in amplicon pools of FAM-labeled PCR products, using the intercalating dye EvaGreen to monitor amplification. Method accuracy was evaluated using mixtures of cloned 16S rRNA genes, DNA extracted from low- and high-G+C bacterial isolates (Escherichia coli, Rhodococcus, Variovorax, and Microbacterium), and DNA from soil microcosms amended with known amounts of genomic DNA from bacterial isolates. Improved resolution of minor shifts in buoyant density relative to TRFLP analysis alone was confirmed using well-controlled SIP analyses.

  19. The effect of induced mutations on quantitative traits in Arabidopsis thaliana: Natural versus artificial conditions.

    PubMed

    Stearns, Frank W; Fenster, Charles B

    2016-12-01

    Mutations are the ultimate source of all genetic variations. New mutations are expected to affect quantitative traits differently depending on the extent to which traits contribute to fitness and the environment in which they are tested. The dogma is that the preponderance of mutations affecting fitness will be skewed toward deleterious while their effects on nonfitness traits will be bidirectionally distributed. There are mixed views on the role of stress in modulating these effects. We quantify mutation effects by inducing mutations in Arabidopsis thaliana (Columbia accession) using the chemical ethylmethane sulfonate. We measured the effects of new mutations relative to a premutation founder for fitness components under both natural (field) and artificial (growth room) conditions. Additionally, we measured three other quantitative traits, not expected to contribute directly to fitness, under artificial conditions. We found that induced mutations were equally as likely to increase as decrease a trait when that trait was not closely related to fitness (traits that were neither survivorship nor reproduction). We also found that new mutations were more likely to decrease fitness or fitness-related traits under more stressful field conditions than under relatively benign artificial conditions. In the benign condition, the effect of new mutations on fitness components was similar to traits not as closely related to fitness. These results highlight the importance of measuring the effects of new mutations on fitness and other traits under a range of conditions.

  20. Use of the HR index to predict maximal oxygen uptake during different exercise protocols.

    PubMed

    Haller, Jeannie M; Fehling, Patricia C; Barr, David A; Storer, Thomas W; Cooper, Christopher B; Smith, Denise L

    2013-10-01

    This study examined the ability of the HRindex model to accurately predict maximal oxygen uptake ([Formula: see text]O2max) across a variety of incremental exercise protocols. Ten men completed five incremental protocols to volitional exhaustion. Protocols included three treadmill (Bruce, UCLA running, Wellness Fitness Initiative [WFI]), one cycle, and one field (shuttle) test. The HRindex prediction equation (METs = 6 × HRindex - 5, where HRindex = HRmax/HRrest) was used to generate estimates of energy expenditure, which were converted to body mass-specific estimates of [Formula: see text]O2max. Estimated [Formula: see text]O2max was compared with measured [Formula: see text]O2max. Across all protocols, the HRindex model significantly underestimated [Formula: see text]O2max by 5.1 mL·kg(-1)·min(-1) (95% CI: -7.4, -2.7) and the standard error of the estimate (SEE) was 6.7 mL·kg(-1)·min(-1). Accuracy of the model was protocol-dependent, with [Formula: see text]O2max significantly underestimated for the Bruce and WFI protocols but not the UCLA, Cycle, or Shuttle protocols. Although no significant differences in [Formula: see text]O2max estimates were identified for these three protocols, predictive accuracy among them was not high, with root mean squared errors and SEEs ranging from 7.6 to 10.3 mL·kg(-1)·min(-1) and from 4.5 to 8.0 mL·kg(-1)·min(-1), respectively. Correlations between measured and predicted [Formula: see text]O2max were between 0.27 and 0.53. Individual prediction errors indicated that prediction accuracy varied considerably within protocols and among participants. In conclusion, across various protocols the HRindex model significantly underestimated [Formula: see text]O2max in a group of aerobically fit young men. Estimates generated using the model did not differ from measured [Formula: see text]O2max for three of the five protocols studied; nevertheless, some individual prediction errors were large. The lack of precision among estimates

  1. A formal protocol test procedure for the Survivable Adaptable Fiber Optic Embedded Network (SAFENET)

    NASA Astrophysics Data System (ADS)

    High, Wayne

    1993-03-01

    This thesis focuses upon a new method for verifying the correct operation of a complex, high speed fiber optic communication network. These networks are of growing importance to the military because of their increased connectivity, survivability, and reconfigurability. With the introduction and increased dependence on sophisticated software and protocols, it is essential that their operation be correct. Because of the speed and complexity of fiber optic networks being designed today, they are becoming increasingly difficult to test. Previously, testing was accomplished by application of conformance test methods which had little connection with an implementation's specification. The major goal of conformance testing is to ensure that the implementation of a profile is consistent with its specification. Formal specification is needed to ensure that the implementation performs its intended operations while exhibiting desirable behaviors. The new conformance test method presented is based upon the System of Communicating Machine model which uses a formal protocol specification to generate a test sequence. The major contribution of this thesis is the application of the System of Communicating Machine model to formal profile specifications of the Survivable Adaptable Fiber Optic Embedded Network (SAFENET) standard which results in the derivation of test sequences for a SAFENET profile. The results applying this new method to SAFENET's OSI and Lightweight profiles are presented.

  2. The Montreal Protocol for Identification of Amusia.

    PubMed

    Vuvan, D T; Paquette, S; Mignault Goulet, G; Royal, I; Felezeu, M; Peretz, I

    2018-04-01

    The Montreal Battery for the Evaluation of Amusia (MBEA; Peretz, Champod, & Hyde Annals of the New York Academy of Sciences, 999, 58-75, 2003) is an empirically grounded quantitative tool that is widely used to identify individuals with congenital amusia. The use of such a standardized measure ensures that the individuals tested will conform to a specific neuropsychological profile, allowing for comparisons across studies and research groups. Recently, a number of researchers have published credible critiques of the usefulness of the MBEA as a diagnostic tool for amusia. Here we argue that the MBEA and its online counterpart, the AMUSIA tests (Peretz et al. Music Perception, 25, 331-343, 2008), should be considered steps in a screening process for amusia, rather than standalone diagnostic tools. The goal of this article is to present, in detailed and easily replicable format, the full protocol through which congenital amusics should be identified. In providing information that has often gone unreported in published articles, we aim to clarify the strengths and limitations of the MBEA and to make recommendations for its continued use by the research community as part of the Montreal Protocol for Identification of Amusia.

  3. Regulatory fit effects on children's responses to healthy eating promotion: an experiment testing message and celebrity fit.

    PubMed

    Cheng, Benjamin Ka Lun

    2015-01-01

    This study adopts the regulatory fit theory and examines the effects of the celebrity and message fit on children's responses to the promotion of healthy eating. A 2 × 2 experiment was conducted with 87 Hong Kong children ages 11 to 16. The results showed that a regulatory fit between the celebrity focus and the message focus yielded a better affective response. Specifically, children found a poster ad more convincing, liked it more, held more positive feelings, and found the poster ad more interesting in the fit conditions. Implications and future research directions were discussed.

  4. Fitted hyperelastic parameters for Human brain tissue from reported tension, compression, and shear tests.

    PubMed

    Moran, Richard; Smith, Joshua H; García, José J

    2014-11-28

    The mechanical properties of human brain tissue are the subject of interest because of their use in understanding brain trauma and in developing therapeutic treatments and procedures. To represent the behavior of the tissue, we have developed hyperelastic mechanical models whose parameters are fitted in accordance with experimental test results. However, most studies available in the literature have fitted parameters with data of a single type of loading, such as tension, compression, or shear. Recently, Jin et al. (Journal of Biomechanics 46:2795-2801, 2013) reported data from ex vivo tests of human brain tissue under tension, compression, and shear loading using four strain rates and four different brain regions. However, they do not report parameters of energy functions that can be readily used in finite element simulations. To represent the tissue behavior for the quasi-static loading conditions, we aimed to determine the best fit of the hyperelastic parameters of the hyperfoam, Ogden, and polynomial strain energy functions available in ABAQUS for the low strain rate data, while simultaneously considering all three loading modes. We used an optimization process conducted in MATLAB, calling iteratively three finite element models developed in ABAQUS that represent the three loadings. Results showed a relatively good fit to experimental data in all loading modes using two terms in the energy functions. Values for the shear modulus obtained in this analysis (897-1653Pa) are in the range of those presented in other studies. These energy-function parameters can be used in brain tissue simulations using finite element models. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Limited-Information Goodness-of-Fit Testing of Diagnostic Classification Item Response Theory Models. CRESST Report 840

    ERIC Educational Resources Information Center

    Hansen, Mark; Cai, Li; Monroe, Scott; Li, Zhen

    2014-01-01

    It is a well-known problem in testing the fit of models to multinomial data that the full underlying contingency table will inevitably be sparse for tests of reasonable length and for realistic sample sizes. Under such conditions, full-information test statistics such as Pearson's X[superscript 2]?? and the likelihood ratio statistic…

  6. Inferring genetic interactions from comparative fitness data.

    PubMed

    Crona, Kristina; Gavryushkin, Alex; Greene, Devin; Beerenwinkel, Niko

    2017-12-20

    Darwinian fitness is a central concept in evolutionary biology. In practice, however, it is hardly possible to measure fitness for all genotypes in a natural population. Here, we present quantitative tools to make inferences about epistatic gene interactions when the fitness landscape is only incompletely determined due to imprecise measurements or missing observations. We demonstrate that genetic interactions can often be inferred from fitness rank orders, where all genotypes are ordered according to fitness, and even from partial fitness orders. We provide a complete characterization of rank orders that imply higher order epistasis. Our theory applies to all common types of gene interactions and facilitates comprehensive investigations of diverse genetic interactions. We analyzed various genetic systems comprising HIV-1, the malaria-causing parasite Plasmodium vivax , the fungus Aspergillus niger , and the TEM-family of β-lactamase associated with antibiotic resistance. For all systems, our approach revealed higher order interactions among mutations.

  7. Revisiting susceptibility testing in MDR-TB by a standardized quantitative phenotypic assessment in a European multicentre study.

    PubMed

    Cambau, E; Viveiros, M; Machado, D; Raskine, L; Ritter, C; Tortoli, E; Matthys, V; Hoffner, S; Richter, E; Perez Del Molino, M L; Cirillo, D M; van Soolingen, D; Böttger, E C

    2015-03-01

    Treatment outcome of MDR-TB is critically dependent on the proper use of second-line drugs as per the result of in vitro drug susceptibility testing (DST). We aimed to establish a standardized DST procedure based on quantitative determination of drug resistance and compared the results with those of genotypes associated with drug resistance. The protocol, based on MGIT 960 and the TB eXiST software, was evaluated in nine European reference laboratories. Resistance detection at a screening drug concentration was followed by determination of resistance levels and estimation of the resistance proportion. Mutations in 14 gene regions were investigated using established techniques. A total of 139 Mycobacterium tuberculosis isolates from patients with MDR-TB and resistance beyond MDR-TB were tested for 13 antituberculous drugs: isoniazid, rifampicin, rifabutin, ethambutol, pyrazinamide, streptomycin, para-aminosalicylic acid, ethionamide, amikacin, capreomycin, ofloxacin, moxifloxacin and linezolid. Concordance between phenotypic and genotypic resistance was >80%, except for ethambutol. Time to results was short (median 10 days). High-level resistance, which precludes the therapeutic use of an antituberculous drug, was observed in 49% of the isolates. The finding of a low or intermediate resistance level in 16% and 35% of the isolates, respectively, may help in designing an efficient personalized regimen for the treatment of MDR-TB patients. The automated DST procedure permits accurate and rapid quantitative resistance profiling of first- and second-line antituberculous drugs. Prospective validation is warranted to determine the impact on patient care. © The Author 2014. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  8. The cardiopulmonary exercise test grey zone; optimising fitness stratification by application of critical difference.

    PubMed

    Rose, G A; Davies, R G; Davison, G W; Adams, R A; Williams, I M; Lewis, M H; Appadurai, I R; Bailey, D M

    2018-06-01

    Cardiorespiratory fitness can inform patient care, although to what extent natural variation in CRF influences clinical practice remains to be established. We calculated natural variation for cardiopulmonary exercise test (CPET) metrics, which may have implications for fitness stratification. In a two-armed experiment, critical difference comprising analytical imprecision and biological variation was calculated for cardiorespiratory fitness and thus defined the magnitude of change required to claim a clinically meaningful change. This metric was retrospectively applied to 213 patients scheduled for colorectal surgery. These patients underwent CPET and the potential for misclassification of fitness was calculated. We created a model with boundaries inclusive of natural variation [critical difference applied to oxygen uptake at anaerobic threshold (V˙O 2 -AT): 11 ml O 2  kg -1  min -1 , peak oxygen uptake (V˙O 2 peak): 16 ml O 2  kg -1  min -1 , and ventilatory equivalent for carbon dioxide at AT (V̇ E /V̇CO 2 -AT): 36]. The critical difference for V˙O 2 -AT, V˙O 2 peak, and V˙ E /V˙CO 2 -AT was 19%, 13%, and 10%, respectively, resulting in false negative and false positive rates of up to 28% and 32% for unfit patients. Our model identified boundaries for unfit and fit patients: AT <9.2 and ≥13.6 ml O 2  kg -1  min -1 , V˙O 2 peak <14.2 and ≥18.3 ml kg -1  min -1 , V˙ E /V˙CO 2 -AT ≥40.1 and <32.7, between which an area of indeterminate-fitness was established. With natural variation considered, up to 60% of patients presented with indeterminate-fitness. These findings support a reappraisal of current clinical interpretation of cardiorespiratory fitness highlighting the potential for incorrect fitness stratification when natural variation is not accounted for. Copyright © 2018 British Journal of Anaesthesia. All rights reserved.

  9. Feasibility and repeatability of cold and mechanical quantitative sensory testing in normal dogs

    PubMed Central

    Briley, Jessica D.; Williams, Morika D.; Freire, Mila; Griffith, Emily H.; Lascelles, B. Duncan X.

    2015-01-01

    Feasibility and inter-session repeatability of cold and mechanical quantitative sensory testing (QST) were assessed in 24 normal dogs. Cold thermal latencies were evaluated using a thermal probe (0 °C) applied to three pelvic limb sites. Mechanical thresholds were measured using an electronic von Frey anesthesiometer (EVF) and a blunt-probed pressure algometer (PA) applied to the dorsal aspect of the metatarsus. All QST trials were performed with dogs in lateral recumbency. Collection of cold QST data was easy (feasible) in 19/24 (79%) dogs. However, only 18.4%, 18.9% and 13.2% of cold QST trials elicited a response at the medial tibia, third digital pad and plantar metatarsal regions, respectively. Collection of mechanical QST data was easy (feasible) in 20/24 (83%) dogs for both EVF and PA. At consecutive sampling times, approximately 2 weeks apart, the average EVF sensory thresholds were 414 ± 186 g and 379 ± 166 g, respectively, and the average PA sensory thresholds were 1089 ± 414 g and 1028 ± 331 g, respectively. There was no significant difference in inter-session or inter-limb threshold values for either mechanical QST device. The cold QST protocol in this study was achievable, but did not provide consistently quantifiable results. Both mechanical QST devices tested provided repeatable, reliable sensory threshold measurements in normal, client-owned dogs. These findings contribute to the validation of the EVF and PA as tools to obtain repeated QST data over time in dogs to assess somatosensory processing changes. PMID:24268475

  10. Thermal quantitative sensory testing to assess the sensory effects of three local anesthetic solutions in a randomized trial of interscalene blockade for shoulder surgery.

    PubMed

    Sermeus, Luc A; Hans, Guy H; Schepens, Tom; Bosserez, Nathalie M-L; Breebaart, Margaretha B; Smitz, Carine J; Vercauteren, Marcel P

    2016-01-01

    This study investigated whether quantitative sensory testing (QST) with thermal stimulations can quantitatively measure the characteristics of an ultrasound-guided interscalene brachial plexus block (US-ISB). This was a prospective randomized trial in patients scheduled for arthroscopic shoulder surgery under general anesthesia and US-ISB. Participants and observers were blinded for the study. We assigned the study participants to one of three groups: 0.5% levobupivacaine 15 mL, 0.5% levobupivacaine 15 mL with 1:200,000 epinephrine, and 0.75% ropivacaine 15 mL. We performed thermal QST within dermatomes C4, C5, C6, and C7 before infiltration and 30 min, six hours, ten hours, and 24 hr after performing the US-ISB. In addition, we used QST, a semi-objective quantitative testing method, to measure the onset, intensity, duration, extent, and functional recovery of the sensory block. We also measured detection thresholds for cold/warm sensations and cold/heat pain. Detection thresholds for all thermal sensations within the ipsilateral C4, C5, C6, and C7 dermatomes increased rapidly (indicating the development of a hypoesthetic state) and reached a steady state after 30 min. This lasted for approximately ten hours and returned to normal detection thresholds by 24 hr. There were no differences detected between the three groups at 24 hr when we compared warm sensation thresholds on one dermatome. Visual inspection of the pooled results per dermatome suggests the ability of QST to detect clinically relevant differences in block intensity per dermatome. Quantitative sensory testing can be useful as a method for detecting the presence and characteristics of regional anesthesia-induced sensory block and may be used for the evaluation of clinical protocols. The three local anesthetic solutions exhibited a similar anesthetic effect. The results support the use of QST to assess block characteristics quantitatively under clinical research conditions. This trial was registered at

  11. Development of Standardized Material Testing Protocols for Prosthetic Liners

    PubMed Central

    Cagle, John C.; Reinhall, Per G.; Hafner, Brian J.; Sanders, Joan E.

    2017-01-01

    A set of protocols was created to characterize prosthetic liners across six clinically relevant material properties. Properties included compressive elasticity, shear elasticity, tensile elasticity, volumetric elasticity, coefficient of friction (CoF), and thermal conductivity. Eighteen prosthetic liners representing the diverse range of commercial products were evaluated to create test procedures that maximized repeatability, minimized error, and provided clinically meaningful results. Shear and tensile elasticity test designs were augmented with finite element analysis (FEA) to optimize specimen geometries. Results showed that because of the wide range of available liner products, the compressive elasticity and tensile elasticity tests required two test maxima; samples were tested until they met either a strain-based or a stress-based maximum, whichever was reached first. The shear and tensile elasticity tests required that no cyclic conditioning be conducted because of limited endurance of the mounting adhesive with some liner materials. The coefficient of friction test was based on dynamic coefficient of friction, as it proved to be a more reliable measurement than static coefficient of friction. The volumetric elasticity test required that air be released beneath samples in the test chamber before testing. The thermal conductivity test best reflected the clinical environment when thermal grease was omitted and when liner samples were placed under pressure consistent with load bearing conditions. The developed procedures provide a standardized approach for evaluating liner products in the prosthetics industry. Test results can be used to improve clinical selection of liners for individual patients and guide development of new liner products. PMID:28233885

  12. A protocol of rope skipping exercise for primary school children: A pilot test

    NASA Astrophysics Data System (ADS)

    Radzi, A. N. M.; Rambely, A. S.; Chellapan, K.

    2014-06-01

    This paper aims to investigate the methods and sample used in rope skipping as an exercise approach. A systematic literature review was approached in identifying skipping performance in the related researches. The methods were compared to determine the best methodological approach for the targeted skipping based research measure. A pilot test was performed among seven students below 12 years old. As the outcome of the review, a skipping protocol design has been proposed for 10 years old primary school students. The proposed protocol design is to be submitted to PPUKM Ethical Committee for approval prior to its implementation in investigation memory enhancement in relation to designed skipping activities.

  13. A goodness-of-fit test for capture-recapture model M(t) under closure

    USGS Publications Warehouse

    Stanley, T.R.; Burnham, K.P.

    1999-01-01

    A new, fully efficient goodness-of-fit test for the time-specific closed-population capture-recapture model M(t) is presented. This test is based on the residual distribution of the capture history data given the maximum likelihood parameter estimates under model M(t), is partitioned into informative components, and is based on chi-square statistics. Comparison of this test with Leslie's test (Leslie, 1958, Journal of Animal Ecology 27, 84- 86) for model M(t), using Monte Carlo simulations, shows the new test generally outperforms Leslie's test. The new test is frequently computable when Leslie's test is not, has Type I error rates that are closer to nominal error rates than Leslie's test, and is sensitive to behavioral variation and heterogeneity in capture probabilities. Leslie's test is not sensitive to behavioral variation in capture probabilities but, when computable, has greater power to detect heterogeneity than the new test.

  14. A comparison of battery testing protocols: Those used by the U.S. advanced battery consortium and those used in China

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robertson, David C.; Christophersen, Jon P.; Bennett, Taylor

    Two testing protocols, QC/T 743 and those used by the U.S. Advanced Battery Consortium (USABC), were compared using cells based on LiFePO4/graphite chemistry. Differences in the protocols directly affected the data and the performance decline mechanisms deduced from the data. In all cases, the rate of capacity fade was linear with time. Overall, the testing protocols produced very similar data when the testing conditions and metrics used to define performance were similar. The choice of depth of discharge and pulse width had a direct effect on the apparent rate of resistance increased and estimated cell life. At greater percent depthmore » of discharge (%DOD) and pulse width, the estimated life was shorter that at lower %DOD and shorter pulse width. This indicates that cells which were at the end of life based on the USABC protocol were not at end of life based on the QC/T 743 protocol by a large margin. (C) 2016 ELSEVIER B.V. All rights reserved.« less

  15. Pearson-type goodness-of-fit test with bootstrap maximum likelihood estimation.

    PubMed

    Yin, Guosheng; Ma, Yanyuan

    2013-01-01

    The Pearson test statistic is constructed by partitioning the data into bins and computing the difference between the observed and expected counts in these bins. If the maximum likelihood estimator (MLE) of the original data is used, the statistic generally does not follow a chi-squared distribution or any explicit distribution. We propose a bootstrap-based modification of the Pearson test statistic to recover the chi-squared distribution. We compute the observed and expected counts in the partitioned bins by using the MLE obtained from a bootstrap sample. This bootstrap-sample MLE adjusts exactly the right amount of randomness to the test statistic, and recovers the chi-squared distribution. The bootstrap chi-squared test is easy to implement, as it only requires fitting exactly the same model to the bootstrap data to obtain the corresponding MLE, and then constructs the bin counts based on the original data. We examine the test size and power of the new model diagnostic procedure using simulation studies and illustrate it with a real data set.

  16. Development of a framework for international certification by OIE of diagnostic tests validated as fit for purpose.

    PubMed

    Wright, P; Edwards, S; Diallo, A; Jacobson, R

    2006-01-01

    Historically, the OIE has focused on test methods applicable to trade and the international movement of animals and animal products. With its expanding role as the World Organisation for Animal Health, the OIE has recognised the need to evaluate test methods relative to specific diagnostic applications other than trade. In collaboration with its international partners, the OIE solicited input from experts through consultants' meetings on the development of guidelines for validation and certification of diagnostic assays for infectious animal diseases. Recommendations from the first meeting were formally adopted and have subsequently been acted upon by the OIE. A validation template has been developed that specifically requires a test to be fit or suited for its intended purpose (e.g. as a screening or a confirmatory test). This is a key criterion for validation. The template incorporates four distinct stages of validation, each of which has bearing on the evaluation of fitness for purpose. The OIE has just recently created a registry for diagnostic tests that fulfil these validation requirements. Assay developers are invited to submit validation dossiers to the OIE for evaluation by a panel of experts. Recognising that validation is an incremental process, tests methods achieving at least the first stages of validation may be provisionally accepted. To provide additional confidence in assay performance, the OIE, through its network of Reference Laboratories, has embarked on the development of evaluation panels. These panels would contain specially selected test samples that would assist in verifying fitness for purpose.

  17. Validation of an Instrument to Measure High School Students' Attitudes toward Fitness Testing

    ERIC Educational Resources Information Center

    Mercier, Kevin; Silverman, Stephen

    2014-01-01

    Purpose: The purpose of this investigation was to develop an instrument that has scores that are valid and reliable for measuring students' attitudes toward fitness testing. Method: The method involved the following steps: (a) an elicitation study, (b) item development, (c) a pilot study, and (d) a validation study. The pilot study included 427…

  18. An anthropomorphic phantom for quantitative evaluation of breast MRI.

    PubMed

    Freed, Melanie; de Zwart, Jacco A; Loud, Jennifer T; El Khouli, Riham H; Myers, Kyle J; Greene, Mark H; Duyn, Jeff H; Badano, Aldo

    2011-02-01

    In this study, the authors aim to develop a physical, tissue-mimicking phantom for quantitative evaluation of breast MRI protocols. The objective of this phantom is to address the need for improved standardization in breast MRI and provide a platform for evaluating the influence of image protocol parameters on lesion detection and discrimination. Quantitative comparisons between patient and phantom image properties are presented. The phantom is constructed using a mixture of lard and egg whites, resulting in a random structure with separate adipose- and glandular-mimicking components. T1 and T2 relaxation times of the lard and egg components of the phantom were estimated at 1.5 T from inversion recovery and spin-echo scans, respectively, using maximum-likelihood methods. The image structure was examined quantitatively by calculating and comparing spatial covariance matrices of phantom and patient images. A static, enhancing lesion was introduced by creating a hollow mold with stereolithography and filling it with a gadolinium-doped water solution. Measured phantom relaxation values fall within 2 standard errors of human values from the literature and are reasonably stable over 9 months of testing. Comparison of the covariance matrices of phantom and patient data demonstrates that the phantom and patient data have similar image structure. Their covariance matrices are the same to within error bars in the anterior-posterior direction and to within about two error bars in the right-left direction. The signal from the phantom's adipose-mimicking material can be suppressed using active fat-suppression protocols. A static, enhancing lesion can also be included with the ability to change morphology and contrast agent concentration. The authors have constructed a phantom and demonstrated its ability to mimic human breast images in terms of key physical properties that are relevant to breast MRI. This phantom provides a platform for the optimization and standardization of

  19. Test of Achievement in Quantitative Economics for Secondary Schools: Construction and Validation Using Item Response Theory

    ERIC Educational Resources Information Center

    Eleje, Lydia I.; Esomonu, Nkechi P. M.

    2018-01-01

    A Test to measure achievement in quantitative economics among secondary school students was developed and validated in this study. The test is made up 20 multiple choice test items constructed based on quantitative economics sub-skills. Six research questions guided the study. Preliminary validation was done by two experienced teachers in…

  20. Comparison of quantitative and qualitative tests for glucose-6-phosphate dehydrogenase deficiency.

    PubMed

    LaRue, Nicole; Kahn, Maria; Murray, Marjorie; Leader, Brandon T; Bansil, Pooja; McGray, Sarah; Kalnoky, Michael; Zhang, Hao; Huang, Huiqiang; Jiang, Hui; Domingo, Gonzalo J

    2014-10-01

    A barrier to eliminating Plasmodium vivax malaria is inadequate treatment of infected patients. 8-Aminoquinoline-based drugs clear the parasite; however, people with glucose-6-phosphate dehydrogenase (G6PD) deficiency are at risk for hemolysis from these drugs. Understanding the performance of G6PD deficiency tests is critical for patient safety. Two quantitative assays and two qualitative tests were evaluated. The comparison of quantitative assays gave a Pearson correlation coefficient of 0.7585 with significant difference in mean G6PD activity, highlighting the need to adhere to a single reference assay. Both qualitative tests had high sensitivity and negative predictive value at a cutoff G6PD value of 40% of normal activity if interpreted conservatively and performed under laboratory conditions. The performance of both tests dropped at a cutoff level of 45%. Cytochemical staining of specimens confirmed that heterozygous females with > 50% G6PD-deficient cells can seem normal by phenotypic tests. © The American Society of Tropical Medicine and Hygiene.

  1. Experience over fifteen years with a protocol for predictive testing for Huntington disease.

    PubMed

    Dufrasne, Suzanne; Roy, Madeleine; Galvez, Maria; Rosenblatt, David S

    2011-04-01

    To compile a comprehensive profile of the participants who had predictive testing from Huntington disease (HD) between 1994 and 2008 in Montreal, Canada. This is a retrospective cohort study. The predictive testing protocol consisted of a telephone interview to give information about predictive testing and collect demographic data; a psychological assessment and counseling session; a session focused on medical and family history of HD; a session reserved for genetic counseling; a session where results were given to participants; and a follow-up telephone interview. A total of 181 applicants requested presymptomatic testing. 135 applicants (77 women and 58 men) completed the protocol and received test results while 40 withdrew. Of the latter, 3 manifested symptoms of the disease and were referred to a neurologist or psychiatrist, and 3 had previously been tested by linkage analysis. Participants usually mentioned more than one reason for requesting predictive testing but the most frequent was to put an end to uncertainty concerning their risk of illness. The proportion of positive and negatives test results was 40% and 54.1% respectively, significantly different from the expected 50% (p<0.01). Prenatal testing was not frequently requested. All the participants expressed satisfaction regarding their decision to be tested. None to our knowledge had a catastrophic reaction (major depressive disorder or psychiatric hospitalization, declared suicide attempt or suicide). Our study highlights that preparation for receiving test results is a psychologically complex process for which appropriate support in a timely fashion is critical. We feel that a cautious and ethical case by case approach remains essential and that high standards of testing should be maintained because of the far reaching impact of test results. Copyright © 2010 Elsevier Inc. All rights reserved.

  2. D Imaging for Museum Artefacts: a Portable Test Object for Heritage and Museum Documentation of Small Objects

    NASA Astrophysics Data System (ADS)

    Hess, M.; Robson, S.

    2012-07-01

    3D colour image data generated for the recording of small museum objects and archaeological finds are highly variable in quality and fitness for purpose. Whilst current technology is capable of extremely high quality outputs, there are currently no common standards or applicable guidelines in either the museum or engineering domain suited to scientific evaluation, understanding and tendering for 3D colour digital data. This paper firstly explains the rationale towards and requirements for 3D digital documentation in museums. Secondly it describes the design process, development and use of a new portable test object suited to sensor evaluation and the provision of user acceptance metrics. The test object is specifically designed for museums and heritage institutions and includes known surface and geometric properties which support quantitative and comparative imaging on different systems. The development for a supporting protocol will allow object reference data to be included in the data processing workflow with specific reference to conservation and curation.

  3. Finalizing the CCSDS Space-Data Link Layer Security Protocol: Setup and Execution of the Interoperability Testing

    NASA Technical Reports Server (NTRS)

    Fischer, Daniel; Aguilar-Sanchez, Ignacio; Saba, Bruno; Moury, Gilles; Biggerstaff, Craig; Bailey, Brandon; Weiss, Howard; Pilgram, Martin; Richter, Dorothea

    2015-01-01

    The protection of data transmitted over the space-link is an issue of growing importance also for civilian space missions. Through the Consultative Committee for Space Data Systems (CCSDS), space agencies have reacted to this need by specifying the Space Data-Link Layer Security (SDLS) protocol which provides confidentiality and integrity services for the CCSDS Telemetry (TM), Telecommand (TC) and Advanced Orbiting Services (AOS) space data-link protocols. This paper describes the approach of the CCSDS SDLS working group to specify and execute the necessary interoperability tests. It first details the individual SDLS implementations that have been produced by ESA, NASA, and CNES and then the overall architecture that allows the interoperability tests between them. The paper reports on the results of the interoperability tests and identifies relevant aspects for the evolution of the test environment.

  4. Digital evaluation of the fit of zirconia-reinforced lithium silicate crowns with a new three-dimensional approach.

    PubMed

    Zimmermann, Moritz; Valcanaia, Andre; Neiva, Gisele; Mehl, Albert; Fasbinder, Dennis

    2017-11-30

    Several methods for the evaluation of fit of computer-aided design/computer-assisted manufacture (CAD/CAM)-fabricated restorations have been described. In the study, digital models were recorded with an intraoral scanning device and were measured using a new three-dimensional (3D) computer technique to evaluate restoration internal fit. The aim of the study was to evaluate the internal adaptation and fit of chairside CAD/CAM-fabricated zirconia-reinforced lithium silicate ceramic crowns fabricated with different post-milling protocols. The null hypothesis was that different post-milling protocols did not influence the fitting accuracy of zirconia-reinforced lithium silicate restorations. A master all-ceramic crown preparation was completed on a maxillary right first molar on a typodont. Twenty zirconia-reinforced lithium silicate ceramic crowns (Celtra Duo, Dentsply Sirona) were designed and milled using a chairside CAD/CAM system (CEREC Omnicam, Dentsply Sirona). The 20 crowns were randomly divided into two groups based on post-milling protocols: no manipulation after milling (Group MI) and oven fired-glazing after milling (Group FG). A 3D computer method was used to evaluate the internal adaptation of the crowns. This was based on a subtractive analysis of a digital scan of the crown preparation and a digital scan of the thickness of the cement space over the crown preparation as recorded by a polyvinylsiloxane (PVS) impression material. The preparation scan and PVS scan were matched in 3D and a 3D difference analysis was performed with a software program (OraCheck, Cyfex). Three areas of internal adaptation and fit were selected for analysis: margin (MA), axial wall (AX), and occlusal surface (OC). Statistical analysis was performed using 80% percentile and one-way ANOVA with post-hoc Scheffé test (P = .05). The closest internal adaptation of the crowns was measured at the axial wall with 102.0 ± 11.7 µm for group MI-AX and 106.3 ± 29.3 µm for group FG

  5. Digital Protocol for Chemical Analysis at Ultralow Concentrations by Surface-Enhanced Raman Scattering.

    PubMed

    de Albuquerque, Carlos Diego L; Sobral-Filho, Regivaldo G; Poppi, Ronei J; Brolo, Alexandre G

    2018-01-16

    Single molecule surface-enhanced Raman spectroscopy (SM-SERS) has the potential to revolutionize quantitative analysis at ultralow concentrations (less than 1 nM). However, there are no established protocols to generalize the application of this technique in analytical chemistry. Here, a protocol for quantification at ultralow concentrations using SM-SERS is proposed. The approach aims to take advantage of the stochastic nature of the single-molecule regime to achieved lower limits of quantification (LOQ). Two emerging contaminants commonly found in aquatic environments, enrofloxacin (ENRO) and ciprofloxacin (CIPRO), were chosen as nonresonant molecular probes. The methodology involves a multivariate resolution curve fitting known as non-negative matrix factorization with alternating least-squares algorithm (NMF-ALS) to solve spectral overlaps. The key element of the quantification is to realize that, under SM-SERS conditions, the Raman intensity generated by a molecule adsorbed on a "hotspot" can be digitalized. Therefore, the number of SERS event counts (rather than SERS intensities) was shown to be proportional to the solution concentration. This allowed the determination of both ENRO and CIPRO with high accuracy and precision even at ultralow concentrations regime. The LOQ for both ENRO and CIPRO were achieved at 2.8 pM. The digital SERS protocol, suggested here, is a roadmap for the implementation of SM-SERS as a routine tool for quantification at ultralow concentrations.

  6. Use of the bootstrap method to develop a physical fitness test for public safety officers who serve as both police officers and firefighters

    PubMed Central

    Cheng, Dunlei; Lee, John; Shock, Tiffany; Kennedy, Kathleen; Pate, Scotty

    2014-01-01

    Physical fitness testing is a common tool for motivating employees with strenuous occupations to reach and maintain a minimum level of fitness. Nevertheless, the use of such tests can be hampered by several factors, including required compliance with US antidiscrimination laws. The Highland Park (Texas) Department of Public Safety implemented testing in 1991, but no single test adequately evaluated its sworn employees, who are cross-trained and serve as police officers and firefighters. In 2010, the department's fitness experts worked with exercise physiologists from Baylor Heart and Vascular Hospital to develop and evaluate a single test that would be equitable regardless of race/ethnicity, disability, sex, or age >50 years. The new test comprised a series of exercises to assess overall fitness, followed by two sequences of job-specific tasks related to firefighting and police work, respectively. The study group of 50 public safety officers took the test; raw data (e.g., the number of repetitions performed or the time required to complete a task) were collected during three quarterly testing sessions. The statistical bootstrap method was then used to determine the levels of performance that would correlate with 0, 1, 2, or 3 points for each task. A sensitivity analysis was done to determine the overall minimum passing score of 17 points. The new physical fitness test and scoring system have been incorporated into the department's policies and procedures as part of the town's overall employee fitness program. PMID:24982558

  7. The APOSTEL recommendations for reporting quantitative optical coherence tomography studies.

    PubMed

    Cruz-Herranz, Andrés; Balk, Lisanne J; Oberwahrenbrock, Timm; Saidha, Shiv; Martinez-Lapiscina, Elena H; Lagreze, Wolf A; Schuman, Joel S; Villoslada, Pablo; Calabresi, Peter; Balcer, Laura; Petzold, Axel; Green, Ari J; Paul, Friedemann; Brandt, Alexander U; Albrecht, Philipp

    2016-06-14

    To develop consensus recommendations for reporting of quantitative optical coherence tomography (OCT) study results. A panel of experienced OCT researchers (including 11 neurologists, 2 ophthalmologists, and 2 neuroscientists) discussed requirements for performing and reporting quantitative analyses of retinal morphology and developed a list of initial recommendations based on experience and previous studies. The list of recommendations was subsequently revised during several meetings of the coordinating group. We provide a 9-point checklist encompassing aspects deemed relevant when reporting quantitative OCT studies. The areas covered are study protocol, acquisition device, acquisition settings, scanning protocol, funduscopic imaging, postacquisition data selection, postacquisition data analysis, recommended nomenclature, and statistical analysis. The Advised Protocol for OCT Study Terminology and Elements recommendations include core items to standardize and improve quality of reporting in quantitative OCT studies. The recommendations will make reporting of quantitative OCT studies more consistent and in line with existing standards for reporting research in other biomedical areas. The recommendations originated from expert consensus and thus represent Class IV evidence. They will need to be regularly adjusted according to new insights and practices. © 2016 American Academy of Neurology.

  8. Test Protocol for Room-to-Room Distribution of Outside Air by Residential Ventilation Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barley, C. D.; Anderson, R.; Hendron, B.

    2007-12-01

    This test and analysis protocol has been developed as a practical approach for measuring outside air distribution in homes. It has been used successfully in field tests and has led to significant insights on ventilation design issues. Performance advantages of more sophisticated ventilation systems over simpler, less-costly designs have been verified, and specific problems, such as airflow short-circuiting, have been identified.

  9. 50/50 JP5/ATJ5 Specification and Fit-for-Purpose Test Results

    DTIC Science & Technology

    2014-07-02

    identical to the average CRC handbook JP-5 values. The minor discrepancies between these results are within the experimental error of the method and...50/50 JP5/ATJ5 SPECIFICATION AND FIT-FOR-PURPOSE TEST RESULTS NAVAIR SYSCOM REPORT 441/14-011 2 July 2014 Prepared By: Kristin L. Weisser...3 3.0 RESULTS & DISCUSSION

  10. Inferring genetic interactions from comparative fitness data

    PubMed Central

    2017-01-01

    Darwinian fitness is a central concept in evolutionary biology. In practice, however, it is hardly possible to measure fitness for all genotypes in a natural population. Here, we present quantitative tools to make inferences about epistatic gene interactions when the fitness landscape is only incompletely determined due to imprecise measurements or missing observations. We demonstrate that genetic interactions can often be inferred from fitness rank orders, where all genotypes are ordered according to fitness, and even from partial fitness orders. We provide a complete characterization of rank orders that imply higher order epistasis. Our theory applies to all common types of gene interactions and facilitates comprehensive investigations of diverse genetic interactions. We analyzed various genetic systems comprising HIV-1, the malaria-causing parasite Plasmodium vivax, the fungus Aspergillus niger, and the TEM-family of β-lactamase associated with antibiotic resistance. For all systems, our approach revealed higher order interactions among mutations. PMID:29260711

  11. One Dimensional Turing-Like Handshake Test for Motor Intelligence

    PubMed Central

    Karniel, Amir; Avraham, Guy; Peles, Bat-Chen; Levy-Tzedek, Shelly; Nisky, Ilana

    2010-01-01

    In the Turing test, a computer model is deemed to "think intelligently" if it can generate answers that are not distinguishable from those of a human. However, this test is limited to the linguistic aspects of machine intelligence. A salient function of the brain is the control of movement, and the movement of the human hand is a sophisticated demonstration of this function. Therefore, we propose a Turing-like handshake test, for machine motor intelligence. We administer the test through a telerobotic system in which the interrogator is engaged in a task of holding a robotic stylus and interacting with another party (human or artificial). Instead of asking the interrogator whether the other party is a person or a computer program, we employ a two-alternative forced choice method and ask which of two systems is more human-like. We extract a quantitative grade for each model according to its resemblance to the human handshake motion and name it "Model Human-Likeness Grade" (MHLG). We present three methods to estimate the MHLG. (i) By calculating the proportion of subjects' answers that the model is more human-like than the human; (ii) By comparing two weighted sums of human and model handshakes we fit a psychometric curve and extract the point of subjective equality (PSE); (iii) By comparing a given model with a weighted sum of human and random signal, we fit a psychometric curve to the answers of the interrogator and extract the PSE for the weight of the human in the weighted sum. Altogether, we provide a protocol to test computational models of the human handshake. We believe that building a model is a necessary step in understanding any phenomenon and, in this case, in understanding the neural mechanisms responsible for the generation of the human handshake. PMID:21206462

  12. Fuzzy Performance between Surface Fitting and Energy Distribution in Turbulence Runner

    PubMed Central

    Liang, Zhongwei; Liu, Xiaochu; Ye, Bangyan; Brauwer, Richard Kars

    2012-01-01

    Because the application of surface fitting algorithms exerts a considerable fuzzy influence on the mathematical features of kinetic energy distribution, their relation mechanism in different external conditional parameters must be quantitatively analyzed. Through determining the kinetic energy value of each selected representative position coordinate point by calculating kinetic energy parameters, several typical algorithms of complicated surface fitting are applied for constructing microkinetic energy distribution surface models in the objective turbulence runner with those obtained kinetic energy values. On the base of calculating the newly proposed mathematical features, we construct fuzzy evaluation data sequence and present a new three-dimensional fuzzy quantitative evaluation method; then the value change tendencies of kinetic energy distribution surface features can be clearly quantified, and the fuzzy performance mechanism discipline between the performance results of surface fitting algorithms, the spatial features of turbulence kinetic energy distribution surface, and their respective environmental parameter conditions can be quantitatively analyzed in detail, which results in the acquirement of final conclusions concerning the inherent turbulence kinetic energy distribution performance mechanism and its mathematical relation. A further turbulence energy quantitative study can be ensured. PMID:23213287

  13. Proposed Objective Odor Control Test Methodology for Waste Containment

    NASA Technical Reports Server (NTRS)

    Vos, Gordon

    2010-01-01

    The Orion Cockpit Working Group has requested that an odor control testing methodology be proposed to evaluate the odor containment effectiveness of waste disposal bags to be flown on the Orion Crew Exploration Vehicle. As a standardized "odor containment" test does not appear to be a matter of record for the project, a new test method is being proposed. This method is based on existing test methods used in industrial hygiene for the evaluation of respirator fit in occupational settings, and takes into consideration peer reviewed documentation of human odor thresholds for standardized contaminates, industry stardnard atmostpheric testing methodologies, and established criteria for laboratory analysis. The proposed methodology is quantitative, though it can readily be complimented with a qualitative subjective assessment. Isoamyl acetate (IAA - also known at isopentyl acetate) is commonly used in respirator fit testing, and there are documented methodologies for both measuring its quantitative airborne concentrations. IAA is a clear, colorless liquid with a banana-like odor, documented detectable smell threshold for humans of 0.025 PPM, and a 15 PPB level of quantation limit.

  14. [The Lambert-Beer's law characterization of formal analysis in Terahertz spectrum quantitative testing].

    PubMed

    Su, Hai-Xia; Zhang, Zhao-Hui; Zhao, Xiao-Yan; Li, Zhi; Yan, Fang; Zhang, Han

    2013-12-01

    The present paper discusses the Lambert-Beer' s law application in the terahertz spectrum, studies the single amino acid tablet sample (glutamine) and two kinds of amino acids mixture tablet (threonine and cystine) under the condition of different concentrations. Absorbance and absorption coefficient was analyzed in the description of the terahertz optical properties of matter. By comparing absorption coefficient and absorbance value of the single component in the vicinity of 1. 72 THz, we verified the material under two kinds of absorption characterization of quantity of THz wave absorption along with the change in the concentration. Using the index of goodness of fit R , it studied the stand or fall of linear relationship between the terahertz absorption quantity of material and concentration under two kinds of representation. This paper analyzes the two components mixture under two kinds of absorption characterization of quantity of terahertz absorption in 0. 3-2. 6 THz. Using the similarity co- efficient and the estimate concentration error as evaluation index, it has been clear that the absorbance of additivity instead of the absorption coefficient should be used during the terahertz spectrum quantitative test, and the Lambert-Beer's law application in the terahertz wave band was further clarified.

  15. A Pilot Study for Applying an Extravehicular Activity Exercise Prebreathe Protocol to the International Space Station

    NASA Technical Reports Server (NTRS)

    Woodruff, Kristin K.; Johnson, Anyika N.; Lee, Stuart M. C.; Gernhardt, Michael; Schneider, Suzanne M.; Foster, Philip P.

    2000-01-01

    Decompression sickness (DCS) is a serious risk to astronauts performing extravehicular activity (EVA). To reduce this risk, the addition of ten minutes of moderate exercise (75% VO2pk) during prebreathe has been shown to decrease the total prebreathe time from 4 to 2 hours and to decrease the incidence of DCS. The overall purpose of this pilot study was to develop an exercise protocol using flight hardware and an in-flight physical fitness cycle test to perform prebreathe exercise before an EVA. Eleven subjects volunteered to participate in this study. The first objective of this study was to compare the steady-state heart rate (HR) and oxygen consumption (VO2) from a submaximal arm and leg exercise (ALE) session with those predicted from a maximal ALE test. The second objective was to compare the steady-state HR and V02 from a submaximal elastic tube and leg exercise (TLE) session with those predicted from the maximal ALE test. The third objective involved a comparison of the maximal ALE test with a maximal leg-only (LE) test to conform to the in- flight fitness assessment test. The 75% VO2pk target HR from the LE test was significantly less than the target HR from the ALE test. Prescribing exercise using data from the maximal ALE test resulted in the measured submaximal values being higher than predicted VO2 and HR. The results of this pilot study suggest that elastic tubing is valid during EVA prebreathe as a method of arm exercise with the flight leg ergometer and it is recommended that prebreathe countermeasure exercise protocol incorporate this method.

  16. Validation of quantitative and qualitative methods for detecting allergenic ingredients in processed foods in Japan.

    PubMed

    Sakai, Shinobu; Adachi, Reiko; Akiyama, Hiroshi; Teshima, Reiko

    2013-06-19

    A labeling system for food allergenic ingredients was established in Japan in April 2002. To monitor the labeling, the Japanese government announced official methods for detecting allergens in processed foods in November 2002. The official methods consist of quantitative screening tests using enzyme-linked immunosorbent assays (ELISAs) and qualitative confirmation tests using Western blotting or polymerase chain reactions (PCR). In addition, the Japanese government designated 10 μg protein/g food (the corresponding allergenic ingredient soluble protein weight/food weight), determined by ELISA, as the labeling threshold. To standardize the official methods, the criteria for the validation protocol were described in the official guidelines. This paper, which was presented at the Advances in Food Allergen Detection Symposium, ACS National Meeting and Expo, San Diego, CA, Spring 2012, describes the validation protocol outlined in the official Japanese guidelines, the results of interlaboratory studies for the quantitative detection method (ELISA for crustacean proteins) and the qualitative detection method (PCR for shrimp and crab DNAs), and the reliability of the detection methods.

  17. Small-Sample Adjustments for Tests of Moderators and Model Fit in Robust Variance Estimation in Meta-Regression

    ERIC Educational Resources Information Center

    Tipton, Elizabeth; Pustejovsky, James E.

    2015-01-01

    Randomized experiments are commonly used to evaluate the effectiveness of educational interventions. The goal of the present investigation is to develop small-sample corrections for multiple contrast hypothesis tests (i.e., F-tests) such as the omnibus test of meta-regression fit or a test for equality of three or more levels of a categorical…

  18. Rethinking developmental toxicity testing: Evolution or revolution?

    PubMed

    Scialli, Anthony R; Daston, George; Chen, Connie; Coder, Prägati S; Euling, Susan Y; Foreman, Jennifer; Hoberman, Alan M; Hui, Julia; Knudsen, Thomas; Makris, Susan L; Morford, LaRonda; Piersma, Aldert H; Stanislaus, Dinesh; Thompson, Kary E

    2018-06-01

    Current developmental toxicity testing adheres largely to protocols suggested in 1966 involving the administration of test compound to pregnant laboratory animals. After more than 50 years of embryo-fetal development testing, are we ready to consider a different approach to human developmental toxicity testing? A workshop was held under the auspices of the Developmental and Reproductive Toxicology Technical Committee of the ILSI Health and Environmental Sciences Institute to consider how we might design developmental toxicity testing if we started over with 21st century knowledge and techniques (revolution). We first consider what changes to the current protocols might be recommended to make them more predictive for human risk (evolution). The evolutionary approach includes modifications of existing protocols and can include humanized models, disease models, more accurate assessment and testing of metabolites, and informed approaches to dose selection. The revolution could start with hypothesis-driven testing where we take what we know about a compound or close analog and answer specific questions using targeted experimental techniques rather than a one-protocol-fits-all approach. Central to the idea of hypothesis-driven testing is the concept that testing can be done at the level of mode of action. It might be feasible to identify a small number of key events at a molecular or cellular level that predict an adverse outcome and for which testing could be performed in vitro or in silico or, rarely, using limited in vivo models. Techniques for evaluating these key events exist today or are in development. Opportunities exist for refining and then replacing current developmental toxicity testing protocols using techniques that have already been developed or are within reach. © 2018 The Authors. Birth Defects Research Published by Wiley Periodicals, Inc.

  19. Joint analysis of binary and quantitative traits with data sharing and outcome-dependent sampling.

    PubMed

    Zheng, Gang; Wu, Colin O; Kwak, Minjung; Jiang, Wenhua; Joo, Jungnam; Lima, Joao A C

    2012-04-01

    We study the analysis of a joint association between a genetic marker with both binary (case-control) and quantitative (continuous) traits, where the quantitative trait values are only available for the cases due to data sharing and outcome-dependent sampling. Data sharing becomes common in genetic association studies, and the outcome-dependent sampling is the consequence of data sharing, under which a phenotype of interest is not measured for some subgroup. The trend test (or Pearson's test) and F-test are often, respectively, used to analyze the binary and quantitative traits. Because of the outcome-dependent sampling, the usual F-test can be applied using the subgroup with the observed quantitative traits. We propose a modified F-test by also incorporating the genotype frequencies of the subgroup whose traits are not observed. Further, a combination of this modified F-test and Pearson's test is proposed by Fisher's combination of their P-values as a joint analysis. Because of the correlation of the two analyses, we propose to use a Gamma (scaled chi-squared) distribution to fit the asymptotic null distribution for the joint analysis. The proposed modified F-test and the joint analysis can also be applied to test single trait association (either binary or quantitative trait). Through simulations, we identify the situations under which the proposed tests are more powerful than the existing ones. Application to a real dataset of rheumatoid arthritis is presented. © 2012 Wiley Periodicals, Inc.

  20. The 1-mile walk test is a valid predictor of VO(2max) and is a reliable alternative fitness test to the 1.5-mile run in U.S. Air Force males.

    PubMed

    Weiglein, Laura; Herrick, Jeffery; Kirk, Stacie; Kirk, Erik P

    2011-06-01

    The purpose of this study was to assess the validity of the 1-mile walk (Rockport Walk Test) as a predictor of VO(2max) and determine whether the 1-mile walk is a reliable alternative to the 1.5-mile run in moderately fit to highly fit U.S. Air Force males. Twenty-four (33.0 +/- 1.5 years) males completed a maximal treadmill VO(2max) (50.3 +/- 1.4 mL/ kg/min), 1-mile walk, and 1.5-mile run. For the 1-mile walk, there were no significant differences between measured and predicted VO(2max) (p = 0.177, r = 0.817). There were no significant differences (p = 0.573) between points scored in the Air Force Fitness Test for the 1-mile walk and 1.5-mile run tests. In conclusion, the 1-mile walk test is a valid predictor of VO(2max) and can be used as an alternative fitness test to the 1.5-mile run in assessing cardiovascular fitness in Air Force males.

  1. Goodness-of-Fit Tests for Generalized Normal Distribution for Use in Hydrological Frequency Analysis

    NASA Astrophysics Data System (ADS)

    Das, Samiran

    2018-04-01

    The use of three-parameter generalized normal (GNO) as a hydrological frequency distribution is well recognized, but its application is limited due to unavailability of popular goodness-of-fit (GOF) test statistics. This study develops popular empirical distribution function (EDF)-based test statistics to investigate the goodness-of-fit of the GNO distribution. The focus is on the case most relevant to the hydrologist, namely, that in which the parameter values are unidentified and estimated from a sample using the method of L-moments. The widely used EDF tests such as Kolmogorov-Smirnov, Cramer von Mises, and Anderson-Darling (AD) are considered in this study. A modified version of AD, namely, the Modified Anderson-Darling (MAD) test, is also considered and its performance is assessed against other EDF tests using a power study that incorporates six specific Wakeby distributions (WA-1, WA-2, WA-3, WA-4, WA-5, and WA-6) as the alternative distributions. The critical values of the proposed test statistics are approximated using Monte Carlo techniques and are summarized in chart and regression equation form to show the dependence of shape parameter and sample size. The performance results obtained from the power study suggest that the AD and a variant of the MAD (MAD-L) are the most powerful tests. Finally, the study performs case studies involving annual maximum flow data of selected gauged sites from Irish and US catchments to show the application of the derived critical values and recommends further assessments to be carried out on flow data sets of rivers with various hydrological regimes.

  2. LIFESTYLE INDICATORS AND CARDIORESPIRATORY FITNESS IN ADOLESCENTS

    PubMed Central

    de Victo, Eduardo Rossato; Ferrari, Gerson Luis de Moraes; da Silva, João Pedro; Araújo, Timóteo Leandro; Matsudo, Victor Keihan Rodrigues

    2017-01-01

    ABSTRACT Objective: To evaluate the lifestyle indicators associated with cardiorespiratory fitness in adolescents from Ilhabela, São Paulo, Brazil. Methods: The sample consisted of 181 adolescents (53% male) from the Mixed Longitudinal Project on Growth, Development, and Physical Fitness of Ilhabela. Body composition (weight, height, and body mass index, or BMI), school transportation, time spent sitting, physical activity, sports, television time (TV), having a TV in the bedroom, sleep, health perception, diet, and economic status (ES) were analyzed. Cardiorespiratory fitness was estimated by the submaximal progressive protocol performed on a cycle ergometer. Linear regression models were used with the stepwise method. Results: The sample average age was 14.8 years, and the average cardiorespiratory fitness was 42.2 mL.kg-1.min-1 (42.9 for boys and 41.4 for girls; p=0.341). In the total sample, BMI (unstandardized regression coefficient [B]=-0.03), height (B=-0.01), ES (B=0.10), gender (B=0.12), and age (B=0.03) were significantly associated with cardiorespiratory fitness. In boys, BMI, height, not playing any sports, and age were significantly associated with cardiorespiratory fitness. In girls, BMI, ES, and having a TV in the bedroom were significantly associated with cardiorespiratory fitness. Conclusions: Lifestyle indicators influenced the cardiorespiratory fitness; BMI, ES, and age influenced both sexes. Not playing any sports, for boys, and having a TV in the bedroom, for girls, also influenced cardiorespiratory fitness. Public health measures to improve lifestyle indicators can help to increase cardiorespiratory fitness levels. PMID:28977318

  3. Reliability of a new test battery for fitness assessment of the European Astronaut corps.

    PubMed

    Petersen, Nora; Thieschäfer, Lutz; Ploutz-Snyder, Lori; Damann, Volker; Mester, Joachim

    2015-01-01

    To optimise health for space missions, European astronauts follow specific conditioning programs before, during and after their flights. To evaluate the effectiveness of these programs, the European Space Agency conducts an Astronaut Fitness Assessment (AFA), but the test-retest reliability of elements within it remains unexamined. The reliability study described here presents a scientific basis for implementing the AFA, but also highlights challenges faced by operational teams supporting humans in such unique environments, especially with respect to health and fitness monitoring of crew members travelling not only into space, but also across the world. The AFA tests assessed parameters known to be affected by prolonged exposure to microgravity: aerobic capacity (VO2max), muscular strength (one repetition max, 1 RM) and power (vertical jumps), core stability, flexibility and balance. Intraclass correlation coefficients (ICC3.1), standard error of measurement and coefficient of variation were used to assess relative and absolute test-retest reliability. Squat and bench 1 RM (ICC3.1 = 0.94-0.99), hip flexion (ICC3.1 = 0.99) and left and right handgrip strength (ICC3.1 = 0.95 and 0.97), showed the highest test-retest reliability, followed by VO2max (ICC3.1 = 0.91), core strength (ICC3.1 = 0.78-0.89), hip extension (ICC3.1 = 0.63), the countermeasure (ICC3.1 = 0.76) and squat (ICC3.1 = 0.63) jumps, and single right- and left-leg jump height (ICC3.1 = 0.51 and 0.14). For balance, relative reliability ranged from ICC3.1 = 0.78 for path length (two legs, head tilted back, eyes open) to ICC3.1 = 0.04 for average rotation velocity (one leg, eyes closed). In a small sample (n = 8) of young, healthy individuals, the AFA battery of tests demonstrated acceptable test-retest reliability for most parameters except some balance and single-leg jump tasks. These findings suggest that, for the application with astronauts, most AFA tests appear appropriate to

  4. A test for selection employing quantitative trait locus and mutation accumulation data.

    PubMed

    Rice, Daniel P; Townsend, Jeffrey P

    2012-04-01

    Evolutionary biologists attribute much of the phenotypic diversity observed in nature to the action of natural selection. However, for many phenotypic traits, especially quantitative phenotypic traits, it has been challenging to test for the historical action of selection. An important challenge for biologists studying quantitative traits, therefore, is to distinguish between traits that have evolved under the influence of strong selection and those that have evolved neutrally. Most existing tests for selection employ molecular data, but selection also leaves a mark on the genetic architecture underlying a trait. In particular, the distribution of quantitative trait locus (QTL) effect sizes and the distribution of mutational effects together provide information regarding the history of selection. Despite the increasing availability of QTL and mutation accumulation data, such data have not yet been effectively exploited for this purpose. We present a model of the evolution of QTL and employ it to formulate a test for historical selection. To provide a baseline for neutral evolution of the trait, we estimate the distribution of mutational effects from mutation accumulation experiments. We then apply a maximum-likelihood-based method of inference to estimate the range of selection strengths under which such a distribution of mutations could generate the observed QTL. Our test thus represents the first integration of population genetic theory and QTL data to measure the historical influence of selection.

  5. Distance-based microfluidic quantitative detection methods for point-of-care testing.

    PubMed

    Tian, Tian; Li, Jiuxing; Song, Yanling; Zhou, Leiji; Zhu, Zhi; Yang, Chaoyong James

    2016-04-07

    Equipment-free devices with quantitative readout are of great significance to point-of-care testing (POCT), which provides real-time readout to users and is especially important in low-resource settings. Among various equipment-free approaches, distance-based visual quantitative detection methods rely on reading the visual signal length for corresponding target concentrations, thus eliminating the need for sophisticated instruments. The distance-based methods are low-cost, user-friendly and can be integrated into portable analytical devices. Moreover, such methods enable quantitative detection of various targets by the naked eye. In this review, we first introduce the concept and history of distance-based visual quantitative detection methods. Then, we summarize the main methods for translation of molecular signals to distance-based readout and discuss different microfluidic platforms (glass, PDMS, paper and thread) in terms of applications in biomedical diagnostics, food safety monitoring, and environmental analysis. Finally, the potential and future perspectives are discussed.

  6. The effect of high-intensity circuit training on physical fitness.

    PubMed

    Schmidt, Dan; Anderson, Kaz; Graff, Marissa; Strutz, Victoria

    2016-05-01

    The purpose of this study was to examine the effect of a high-intensity circuit training regimen, using only body weight as resistance, on physical fitness. Ninety-six recreationally active college aged subjects (53 female, 43 male) completed the study. Following baseline testing for height and weight, body composition, aerobic fitness, muscle strength and muscle endurance, subjects were randomly assigned to one of three groups: 7-minute circuit training (CT-7), 14-minute circuit training (CT-14), and a non-training control group (C). Subjects in the CT-7 group (females, N.=17; males, N.=15) were asked to complete a seven minute circuit training workout for eight weeks (three workouts per week). The CT-14 group (females, N.=15; males, N.=13) followed the same protocol as CT-7 through the first four weeks. For the second four weeks they increased exercise time to 14 minutes with the same 7 minute circuit performed twice consecutively. Subjects in group C (females, N.=21; males, N.=15) maintained their normal activity levels throughout the course of the study. There were no significant differences between the groups for any variables tested prior to the exercise intervention. A repeated measures analysis of variance revealed statistically significant improvements in muscular endurance (push-ups) for both male and female subjects in the CT-7 and CT-14 groups. Males in the two exercising groups also showed improvement in muscular strength while aerobic capacity increased for females in the CT-14 group. These results suggest that short duration, high intensity circuit training may improve muscle endurance in moderately fit populations. Slight improvements that are gender specific may also be observed in muscle strength as well as aerobic fitness.

  7. A Quantitative PCR Protocol for Detection of Oxyspirura petrowi in Northern Bobwhites (Colinus virginianus).

    PubMed

    Kistler, Whitney M; Parlos, Julie A; Peper, Steven T; Dunham, Nicholas R; Kendall, Ronald J

    2016-01-01

    Oxyspirura petrowi is a parasitic nematode that infects wild birds. This parasite has a broad host range, but has recently been reported in high prevalences from native Galliformes species in the United States. In order to better understand the impact O. petrowi has on wild bird populations, we developed a quantitative PCR protocol to detect infections in wild northern bobwhites (Colinus virginianus). We used paired fecal and cloacal swab samples from wild caught and experimentally infected northern bobwhites and matching fecal float data from experimentally infected birds to validate our assay. Overall we detected more positive birds from fecal samples than the paired cloacal swabs and there was strong agreement between the qPCR results from fecal samples and from fecal flotation (84%; κ = 0.69 [0.53-0.84 95% CI]). We also detected O. petrowi DNA in ten replicates of samples spiked with one O. petrowi egg. This qPCR assay is an effective assay to detect O. petrowi infections in wild birds. Our results suggest that fecal samples are the most appropriate sample for detecting infections; although, cloacal swabs can be useful for determining if O. petrowi is circulating in a population.

  8. A Quantitative PCR Protocol for Detection of Oxyspirura petrowi in Northern Bobwhites (Colinus virginianus)

    PubMed Central

    Kistler, Whitney M.; Parlos, Julie A.; Peper, Steven T.; Dunham, Nicholas R.; Kendall, Ronald J.

    2016-01-01

    Oxyspirura petrowi is a parasitic nematode that infects wild birds. This parasite has a broad host range, but has recently been reported in high prevalences from native Galliformes species in the United States. In order to better understand the impact O. petrowi has on wild bird populations, we developed a quantitative PCR protocol to detect infections in wild northern bobwhites (Colinus virginianus). We used paired fecal and cloacal swab samples from wild caught and experimentally infected northern bobwhites and matching fecal float data from experimentally infected birds to validate our assay. Overall we detected more positive birds from fecal samples than the paired cloacal swabs and there was strong agreement between the qPCR results from fecal samples and from fecal flotation (84%; κ = 0.69 [0.53–0.84 95% CI]). We also detected O. petrowi DNA in ten replicates of samples spiked with one O. petrowi egg. This qPCR assay is an effective assay to detect O. petrowi infections in wild birds. Our results suggest that fecal samples are the most appropriate sample for detecting infections; although, cloacal swabs can be useful for determining if O. petrowi is circulating in a population. PMID:27893772

  9. Quantitative thermal sensory testing -- value of testing for both cold and warm sensation detection in evaluation of small fiber neuropathy.

    PubMed

    Shukla, Garima; Bhatia, Manvir; Behari, Madhuri

    2005-10-01

    Small fiber neuropathy is a common neurological disorder, often missed or ignored by physicians, since examination and routine nerve conduction studies are usually normal in this condition. Many methods including quantitative thermal sensory testing are currently being used for early detection of this condition, so as to enable timely investigation and treatment. This study was conducted to assess the yield of quantitative thermal sensory testing in diagnosis of small fiber neuropathy. We included patients presenting with history suggestive of positive and/or negative sensory symptoms, with normal examination findings, clinically suggestive of small fiber neuropathy, with normal or minimally abnormal routine nerve conduction studies. These patients were subjected to quantitative thermal sensory testing using a Medoc TSA-II Neurosensory analyser at two sites and for two modalities. QST data were compared with those in 120 normal healthy controls. Twenty-five patients (16 males, 9 females) with mean age 46.8+/-16.6 years (range: 21-75 years) were included in the study. The mean duration of symptoms was 1.6+/-1.6 years (range: 3 months-6 years). Eighteen patients (72%) had abnormal thresholds in at least one modality. Thermal thresholds were normal in 7 out of the 25 patients. This study demonstrates that quantitative thermal sensory testing is a fairly sensitive method for detection of small fiber neuropathy especially in patients with normal routine nerve conduction studies.

  10. Assessment protocols of maximum oxygen consumption in young people with Down syndrome--a review.

    PubMed

    Seron, Bruna Barboza; Greguol, Márcia

    2014-03-01

    Maximum oxygen consumption is considered the gold standard measure of cardiorespiratory fitness. Young people with Down syndrome (DS) present low values of this indicator compared to their peers without disabilities and to young people with an intellectual disability but without DS. The use of reliable and valid assessment methods provides more reliable results for the diagnosis of cardiorespiratory fitness and the response of this variable to exercise. The aim of the present study was to review the literature on the assessment protocols used to measure maximum oxygen consumption in children and adolescents with Down syndrome giving emphasis to the protocols used, the validation process and their feasibility. The search was carried out in eight electronic databases--Scopus, Medline-Pubmed, Web of science, SportDiscus, Cinhal, Academic Search Premier, Scielo, and Lilacs. The inclusion criteria were: (a) articles which assessed VO2peak and/or VO2max (independent of the validation method), (b) samples composed of children and/or adolescents with Down syndrome, (c) participants of up to 20 years old, and (d) studies performed after 1990. Fifteen studies were selected and, of these, 11 measured the VO2peak using tests performed in a laboratory, 2 used field tests and the remaining 2 used both laboratory and field tests. The majority of the selected studies used maximal tests and conducted familiarization sessions. All the studies took into account the clinical conditions that could hamper testing or endanger the individuals. However, a large number of studies used tests which had not been specifically validated for the evaluated population. Finally, the search emphasized the small number of studies which use field tests to evaluate oxygen consumption. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Statistical alignment: computational properties, homology testing and goodness-of-fit.

    PubMed

    Hein, J; Wiuf, C; Knudsen, B; Møller, M B; Wibling, G

    2000-09-08

    The model of insertions and deletions in biological sequences, first formulated by Thorne, Kishino, and Felsenstein in 1991 (the TKF91 model), provides a basis for performing alignment within a statistical framework. Here we investigate this model.Firstly, we show how to accelerate the statistical alignment algorithms several orders of magnitude. The main innovations are to confine likelihood calculations to a band close to the similarity based alignment, to get good initial guesses of the evolutionary parameters and to apply an efficient numerical optimisation algorithm for finding the maximum likelihood estimate. In addition, the recursions originally presented by Thorne, Kishino and Felsenstein can be simplified. Two proteins, about 1500 amino acids long, can be analysed with this method in less than five seconds on a fast desktop computer, which makes this method practical for actual data analysis.Secondly, we propose a new homology test based on this model, where homology means that an ancestor to a sequence pair can be found finitely far back in time. This test has statistical advantages relative to the traditional shuffle test for proteins.Finally, we describe a goodness-of-fit test, that allows testing the proposed insertion-deletion (indel) process inherent to this model and find that real sequences (here globins) probably experience indels longer than one, contrary to what is assumed by the model. Copyright 2000 Academic Press.

  12. Test-retest reliability of probe-microphone verification in children fitted with open and closed hearing aid tips.

    PubMed

    Kim, Hannah; Ricketts, Todd A

    2013-01-01

    To investigate the test-retest reliability of real-ear aided response (REAR) measures in open and closed hearing aid fittings in children using appropriate probe-microphone calibration techniques (stored equalization for open fittings and concurrent equalization for closed fittings). Probe-microphone measurements were completed for two mini-behind-the-ear (BTE) hearing aids which were coupled to the ear using open and closed eartips via thin (0.9 mm) tubing. Before probe-microphone testing, the gain of each of the test hearing aids was programmed using an artificial ear simulator (IEC 711) and a Knowles Electronic Manikin for Acoustic Research to match the National Acoustic Laboratories-Non-Linear, version 1 targets for one of two separate hearing loss configurations using an Audioscan Verifit. No further adjustments were made, and the same amplifier gain was used within each hearing aid across both eartip configurations and all participants. Probe-microphone testing included real-ear occluded response (REOR) and REAR measures using the Verifit's standard speech signal (the carrot passage) presented at 65 dB sound pressure level (SPL). Two repeated probe-microphone measures were made for each participant with the probe-tube and hearing aid removed and repositioned between each trial in order to assess intrasubject measurement variability. These procedures were repeated using both open and closed domes. Thirty-two children, ages ranging from 4 to 14 yr. The test-retest standard deviations for open and closed measures did not exceed 4 dB at any frequency. There was also no significant difference between the open (stored equalization) and closed (concurrent equalization) methods. Reliability was particularly similar in the high frequencies and was also quite similar to that reported in previous research. There was no correlation between reliability and age, suggesting high reliability across all ages evaluated. The findings from this study suggest that reliable probe

  13. High-Impact Aerobic and Zumba Fitness on Increasing VO2MAX, Heart Rate Recovery and Skinfold Thickness

    NASA Astrophysics Data System (ADS)

    Suminar, T. J.; Kusnanik, N. W.; Wiriawan, O.

    2018-01-01

    Purpose of this study is to determine the significant effect of high-impact aerobics exercise, and Zumba fitness on increasing VO2Max, decreasing of heart rate recovery, and decreasing of skinfold thickness. A sample of this study is 30 members aerobics of student activity unit. Type of this study was quantitative by using a quasi-experimental design method. The design of this study used Matching-Only Design. Data were Analyzed by using the t test (paired t-test). The samples divided into three groups consisted of experimental group I, experimental group II, and control group. They were given a treatment for 8 weeks or 24 meeting. For the data, retrieval is done by MFT test, heart rate recovery test, and skinfold thickness test. Furthermore, the result was analyzed by using SPSS 21 series. In conclusion, significant effect of high-impact aerobics and Zumba fitness on increasing VO2Max, heart rate recovery, skinfold thickness.

  14. Fitness consequences of female multiple mating: A direct test of indirect benefits

    PubMed Central

    2012-01-01

    Background The observation that females mate multiply when males provide nothing but sperm - which sexual selection theory suggests is unlikely to be limiting - continues to puzzle evolutionary biologists. Here we test the hypothesis that multiple mating is prevalent under such circumstances because it enhances female fitness. We do this by allowing female Trinidadian guppies to mate with either a single male or with multiple males, and then tracking the consequences of these matings across two generations. Results Overall, multiply mated females produced 67% more F2 grand-offspring than singly mated females. These offspring, however, did not grow or mature faster, nor were they larger at birth, than F2 grand-offspring of singly mated females. Our results, however, show that multiple mating yields benefits to females in the form of an increase in the production of F1. The higher fecundity among multiply mated mothers was driven by greater production of sons but not daughters. However, contrary to expectation, individually, the offspring of multiply mated females do not grow at different rates than offspring of singly mated females, nor do any indirect fitness benefits or costs accrue to second-generation offspring. Conclusions The study provides strong evidence that multiple mating is advantageous to females, even when males contribute only sperm. This benefit is achieved through an increase in fecundity in the first generation, rather than through other fitness correlates such as size at birth, growth rate, time to sexual maturation and survival. Considered alongside previous work that female guppies can choose to mate with multiple partners, our results provide compelling evidence that direct fitness benefits underpin these mating decisions. PMID:22978442

  15. The GP tests of competence assessment: which part best predicts fitness to practise decisions?

    PubMed

    Jayaweera, Hirosha Keshani; Potts, Henry W W; Keshwani, Karim; Valerio, Chris; Baker, Magdalen; Mehdizadeh, Leila; Sturrock, Alison

    2018-01-02

    The General Medical Council (GMC) conducts Tests of Competence (ToC) for doctors referred for Fitness to Practise (FtP) issues. GPs take a single best answer knowledge test, an Objective Structured Clinical Examination (OSCE), and a Simulated Surgery (SimSurg) assessment which is a simulated GP consultation. The aim of this study was to examine the similarities between OSCEs and SimSurg to determine whether each assessment contributed something unique to GP ToCs. A mixed methods approach was used. Data were collated on 153 GPs who were required to undertake a ToC as a part of being investigated for FtP issues between February 2010 and October 2016. Using correlation analysis, we examined to what degree performance on the knowledge test, OSCE, and SimSurg related to case examiner recommendations and FtP outcomes, including the unique predictive power of these three assessments. The outcome measures were case examiner recommendations (i) not fit to practise; ii) fit to practise on a limited basis; or iii) fit to practise) as well as FtP outcomes (i) erased/removed from the register; ii) having restrictions/conditions; or iii) be in good standing). For the qualitative component, 45 GP assessors were asked to rate whether they assess the same competencies and which assessment provides better feedback about candidates. There was significant overlap between OSCEs and SimSurg, p < 0.001. SimSurg had additional predictive power in the presence of OSCEs and the knowledge test (p = 0.030) in distinguishing doctors from different FtP categories, while OSCEs did not (p = 0.080). Both the OSCEs (p = 0.004) and SimSurg (p < 0.001) had significant negative correlations with case examiner recommendations when accounting for the effects of the other two assessments. Inductive thematic analysis of the responses to the questionnaire showed that assessors perceived OSCEs to be better suited to target specific knowledge and skills. SimSurg was thought to produce a

  16. Quantitative test for concave aspheric surfaces using a Babinet compensator.

    PubMed

    Saxena, A K

    1979-08-15

    A quantitative test for the evaluation of surface figures of concave aspheric surfaces using a Babinet compensator is reported. A theoretical estimate of the sensitivity is 0.002lambda for a minimum detectable phase change of 2 pi x 10(-3) rad over a segment length of 1.0 cm.

  17. TH-A-207B-02: QIBA Ultrasound Elasticity Imaging System Biomarker Qualification and User Testing of Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garra, B.

    Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher

  18. Method and platform standardization in MRM-based quantitative plasma proteomics.

    PubMed

    Percy, Andrew J; Chambers, Andrew G; Yang, Juncong; Jackson, Angela M; Domanski, Dominik; Burkhart, Julia; Sickmann, Albert; Borchers, Christoph H

    2013-12-16

    There exists a growing demand in the proteomics community to standardize experimental methods and liquid chromatography-mass spectrometry (LC/MS) platforms in order to enable the acquisition of more precise and accurate quantitative data. This necessity is heightened by the evolving trend of verifying and validating candidate disease biomarkers in complex biofluids, such as blood plasma, through targeted multiple reaction monitoring (MRM)-based approaches with stable isotope-labeled standards (SIS). Considering the lack of performance standards for quantitative plasma proteomics, we previously developed two reference kits to evaluate the MRM with SIS peptide approach using undepleted and non-enriched human plasma. The first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). Here, these kits have been refined for practical use and then evaluated through intra- and inter-laboratory testing on 6 common LC/MS platforms. For an identical panel of 22 plasma proteins, similar concentrations were determined, regardless of the kit, instrument platform, and laboratory of analysis. These results demonstrate the value of the kit and reinforce the utility of standardized methods and protocols. The proteomics community needs standardized experimental protocols and quality control methods in order to improve the reproducibility of MS-based quantitative data. This need is heightened by the evolving trend for MRM-based validation of proposed disease biomarkers in complex biofluids such as blood plasma. We have developed two kits to assist in the inter- and intra-laboratory quality control of MRM experiments: the first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). In this paper, we report the use of these kits in intra- and inter-laboratory testing on 6 common LC/MS platforms. This

  19. Development of a Ground Test and Analysis Protocol for NASA's NextSTEP Phase 2 Habitation Concepts

    NASA Technical Reports Server (NTRS)

    Gernhardt, Michael L.; Beaton, Kara H.; Chappell, Steven P.; Bekdash, Omar S.; Abercromby, Andrew F. J.

    2018-01-01

    The NASA Next Space Technologies for Exploration Partnerships (NextSTEP) program is a public-private partnership model that seeks commercial development of deep space exploration capabilities to support human spaceflight missions around and beyond cislunar space. NASA first issued the Phase 1 NextSTEP Broad Agency Announcement to U.S. industries in 2014, which called for innovative cislunar habitation concepts that leveraged commercialization plans for low-Earth orbit. These habitats will be part of the Deep Space Gateway (DSG), the cislunar space station planned by NASA for construction in the 2020s. In 2016, Phase 2 of the NextSTEP program selected five commercial partners to develop ground prototypes. A team of NASA research engineers and subject matter experts (SMEs) have been tasked with developing the ground-test protocol that will serve as the primary means by which these Phase 2 prototypes will be evaluated. Since 2008, this core test team has successfully conducted multiple spaceflight analog mission evaluations utilizing a consistent set of operational tools, methods, and metrics to enable the iterative development, testing, analysis, and validation of evolving exploration architectures, operations concepts, and vehicle designs. The purpose of implementing a similar evaluation process for the Phase 2 Habitation Concepts is to consistently evaluate different commercial partner ground prototypes to provide data-driven, actionable recommendations for Phase 3. This paper describes the process by which the ground test protocol was developed and the objectives, methods, and metrics by which the NextSTEP Phase 2 Habitation Concepts will be rigorously and systematically evaluated. The protocol has been developed using both a top-down and bottom-up approach. Top-down development began with the Human Exploration and Operations Mission Directorate (HEOMD) exploration objectives and ISS Exploration Capability Study Team (IECST) candidate flight objectives. Strategic

  20. Effects of a 12-Week Physical Activity Protocol Delivered by YMCA After-School Counselors (Youth Fit for Life) on Fitness and Self-Efficacy Changes in 5-12-Year-Old Boys and Girls

    ERIC Educational Resources Information Center

    Annesi, James J.; Westcott, Wayne L.; Faigenbaum, Avery D.; Unruh, Jennifer L.

    2005-01-01

    To address reduced physical education (PE) in elementary schools, a 12-week physical activity protocol was tested on 5-12-year-old, primarily African American, girls (n = 226) and boys (n = 344) at 14 YMCA after-school care sites. The 3 times/week, 45-min session curriculum included cardiovascular, resistance, and flexibility training, in which…

  1. Quantitative impact characterization of aeronautical CFRP materials with non-destructive testing methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kiefel, Denis, E-mail: Denis.Kiefel@airbus.com, E-mail: Rainer.Stoessel@airbus.com; Stoessel, Rainer, E-mail: Denis.Kiefel@airbus.com, E-mail: Rainer.Stoessel@airbus.com; Grosse, Christian, E-mail: Grosse@tum.de

    2015-03-31

    In recent years, an increasing number of safety-relevant structures are designed and manufactured from carbon fiber reinforced polymers (CFRP) in order to reduce weight of airplanes by taking the advantage of their specific strength into account. Non-destructive testing (NDT) methods for quantitative defect analysis of damages are liquid- or air-coupled ultrasonic testing (UT), phased array ultrasonic techniques, and active thermography (IR). The advantage of these testing methods is the applicability on large areas. However, their quantitative information is often limited on impact localization and size. In addition to these techniques, Airbus Group Innovations operates a micro x-ray computed tomography (μ-XCT)more » system, which was developed for CFRP characterization. It is an open system which allows different kinds of acquisition, reconstruction, and data evaluation. One main advantage of this μ-XCT system is its high resolution with 3-dimensional analysis and visualization opportunities, which enables to gain important quantitative information for composite part design and stress analysis. Within this study, different NDT methods will be compared at CFRP samples with specified artificial impact damages. The results can be used to select the most suitable NDT-method for specific application cases. Furthermore, novel evaluation and visualization methods for impact analyzes are developed and will be presented.« less

  2. Implementation of Health Fitness Exercise Programs.

    ERIC Educational Resources Information Center

    Cundiff, David E., Ed.

    This monograph includes the following articles to aid in implementation of fitness concepts: (1) "Trends in Physical Fitness: A Personal Perspective" (H. Harrison Clarke); (2) "A Total Health-Fitness Life-Style" (Steven N. Blair); (3) "Objectives for the Nation--Physical Fitness and Exercise" (Jack H. Wilmore); (4) "A New Physical Fitness Test"…

  3. The Relationship Between Physical Fitness, Preadolescent Obesity, and Academic Achievement in Seventh Grade Students in South Carolina

    NASA Astrophysics Data System (ADS)

    Patterson, Phillip Stephen

    Abstract It was not known if, or to what degree, a relationship existed among academic achievement in science, physical fitness, and preadolescent obesity. This quantitative, correlational study explored the relationship between physical fitness, preadolescent obesity, and academic achievement in 136 seventh grade students at an urban middle school in South Carolina who received 50 minutes of physical education daily for one semester. The researcher hypothesized that the level of physical fitness influences preadolescent obesity and academic performance. The hypotheses stated that there would be a positive correlation between physical fitness and achievement in science, a negative correlation between preadolescent obesity and achievement in science, and a negative correlation between fitness and preadolescent obesity. Pearson product-moment correlations were used to test the hypotheses. Physical fitness was measured using the FitnessGram. Academic performance was measured using the science benchmark assessment. The results revealed that physical fitness was positively correlated with academic achievement (r = .32, p = .001), obesity was negatively related to academic achievement (r = -.27, p = .001), and students' BMI was negatively related to physical fitness (r = -.71, p < .001). The findings of this research have significant implications for school policy and public health in terms of the possibilities for physical activity interventions. Keywords: FitnessGram, physical fitness, preadolescent obesity, body mass index.

  4. Development of a framework for international certification by the OIE of diagnostic tests validated as fit for purpose.

    PubMed

    Wright, P; Edwards, S; Diallo, A; Jacobson, R

    2007-01-01

    Historically, the OIE has focussed on test methods applicable to trade and the international movement of animals and animal products. With its expanding role as the World Organisation for Animal Health, the OIE has recognised the need to evaluate test methods relative to specific diagnostic applications other than trade. In collaboration with its international partners, the OIE solicited input from experts through consultants meetings on the development of guidelines for validation and certification of diagnostic assays for infectious animal diseases. Recommendations from the first meeting were formally adopted and have subsequently been acted upon by the OIE. A validation template has been developed that specifically requires a test to be fit or suited for its intended purpose (e.g. as a screening or a confirmatory test). This is a key criterion for validation. The template incorporates four distinct stages of validation, each of which has bearing on the evaluation of fitness for purpose. The OIE has just recently created a registry for diagnostic tests that fulfil these validation requirements. Assay developers are invited to submit validation dossiers to the OIE for evaluation by a panel of experts. Recognising that validation is an incremental process, tests methods achieving at least the first stages of validation may be provisionally accepted. To provide additional confidence in assay performance, the OIE, through its network of Reference Laboratories, has embarked on the development of evaluation panels. These panels would contain specially selected test samples that would assist in verifying fitness for purpose.

  5. Quantitative confirmation of diffusion-limited oxidation theories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gillen, K.T.; Clough, R.L.

    1990-01-01

    Diffusion-limited (heterogeneous) oxidation effects are often important for studies of polymer degradation. Such effects are common in polymers subjected to ionizing radiation at relatively high dose rate. To better understand the underlying oxidation processes and to aid in the planning of accelerated aging studies, it would be desirable to be able to monitor and quantitatively understand these effects. In this paper, we briefly review a theoretical diffusion approach which derives model profiles for oxygen surrounded sheets of material by combining oxygen permeation rates with kinetically based oxygen consumption expressions. The theory leads to a simple governing expression involving the oxygenmore » consumption and permeation rates together with two model parameters {alpha} and {beta}. To test the theory, gamma-initiated oxidation of a sheet of commercially formulated EPDM rubber was performed under conditions which led to diffusion-limited oxidation. Profile shapes from the theoretical treatments are shown to accurately fit experimentally derived oxidation profiles. In addition, direct measurements on the same EPDM material of the oxygen consumption and permeation rates, together with values of {alpha} and {beta} derived from the fitting procedure, allow us to quantitatively confirm for the first time the governing theoretical relationship. 17 refs., 3 figs.« less

  6. Can quantitative sensory testing predict responses to analgesic treatment?

    PubMed

    Grosen, K; Fischer, I W D; Olesen, A E; Drewes, A M

    2013-10-01

    The role of quantitative sensory testing (QST) in prediction of analgesic effect in humans is scarcely investigated. This updated review assesses the effectiveness in predicting analgesic effects in healthy volunteers, surgical patients and patients with chronic pain. A systematic review of English written, peer-reviewed articles was conducted using PubMed and Embase (1980-2013). Additional studies were identified by chain searching. Search terms included 'quantitative sensory testing', 'sensory testing' and 'analgesics'. Studies on the relationship between QST and response to analgesic treatment in human adults were included. Appraisal of the methodological quality of the included studies was based on evaluative criteria for prognostic studies. Fourteen studies (including 720 individuals) met the inclusion criteria. Significant correlations were observed between responses to analgesics and several QST parameters including (1) heat pain threshold in experimental human pain, (2) electrical and heat pain thresholds, pressure pain tolerance and suprathreshold heat pain in surgical patients, and (3) electrical and heat pain threshold and conditioned pain modulation in patients with chronic pain. Heterogeneity among studies was observed especially with regard to application of QST and type and use of analgesics. Although promising, the current evidence is not sufficiently robust to recommend the use of any specific QST parameter in predicting analgesic response. Future studies should focus on a range of different experimental pain modalities rather than a single static pain stimulation paradigm. © 2013 European Federation of International Association for the Study of Pain Chapters.

  7. Quantitation of Staphylococcus aureus in Seawater Using CHROMagar™ SA

    PubMed Central

    Pombo, David; Hui, Jennifer; Kurano, Michelle; Bankowski, Matthew J; Seifried, Steven E

    2010-01-01

    A microbiological algorithm has been developed to analyze beach water samples for the determination of viable colony forming units (CFU) of Staphylococcus aureus (S. aureus). Membrane filtration enumeration of S. aureus from recreational beach waters using the chromogenic media CHROMagar™SA alone yields a positive predictive value (PPV) of 70%. Presumptive CHROMagar™SA colonies were confirmed as S. aureus by 24-hour tube coagulase test. Combined, these two tests yield a PPV of 100%. This algorithm enables accurate quantitation of S. aureus in seawater in 72 hours and could support risk-prediction processes for recreational waters. A more rapid protocol, utilizing a 4-hour tube coagulase confirmatory test, enables a 48-hour turnaround time with a modest false negative rate of less than 10%. PMID:20222490

  8. Automated, Quantitative Cognitive/Behavioral Screening of Mice: For Genetics, Pharmacology, Animal Cognition and Undergraduate Instruction

    PubMed Central

    Gallistel, C. R.; Balci, Fuat; Freestone, David; Kheifets, Aaron; King, Adam

    2014-01-01

    We describe a high-throughput, high-volume, fully automated, live-in 24/7 behavioral testing system for assessing the effects of genetic and pharmacological manipulations on basic mechanisms of cognition and learning in mice. A standard polypropylene mouse housing tub is connected through an acrylic tube to a standard commercial mouse test box. The test box has 3 hoppers, 2 of which are connected to pellet feeders. All are internally illuminable with an LED and monitored for head entries by infrared (IR) beams. Mice live in the environment, which eliminates handling during screening. They obtain their food during two or more daily feeding periods by performing in operant (instrumental) and Pavlovian (classical) protocols, for which we have written protocol-control software and quasi-real-time data analysis and graphing software. The data analysis and graphing routines are written in a MATLAB-based language created to simplify greatly the analysis of large time-stamped behavioral and physiological event records and to preserve a full data trail from raw data through all intermediate analyses to the published graphs and statistics within a single data structure. The data-analysis code harvests the data several times a day and subjects it to statistical and graphical analyses, which are automatically stored in the "cloud" and on in-lab computers. Thus, the progress of individual mice is visualized and quantified daily. The data-analysis code talks to the protocol-control code, permitting the automated advance from protocol to protocol of individual subjects. The behavioral protocols implemented are matching, autoshaping, timed hopper-switching, risk assessment in timed hopper-switching, impulsivity measurement, and the circadian anticipation of food availability. Open-source protocol-control and data-analysis code makes the addition of new protocols simple. Eight test environments fit in a 48 in x 24 in x 78 in cabinet; two such cabinets (16 environments) may be

  9. Automated, quantitative cognitive/behavioral screening of mice: for genetics, pharmacology, animal cognition and undergraduate instruction.

    PubMed

    Gallistel, C R; Balci, Fuat; Freestone, David; Kheifets, Aaron; King, Adam

    2014-02-26

    We describe a high-throughput, high-volume, fully automated, live-in 24/7 behavioral testing system for assessing the effects of genetic and pharmacological manipulations on basic mechanisms of cognition and learning in mice. A standard polypropylene mouse housing tub is connected through an acrylic tube to a standard commercial mouse test box. The test box has 3 hoppers, 2 of which are connected to pellet feeders. All are internally illuminable with an LED and monitored for head entries by infrared (IR) beams. Mice live in the environment, which eliminates handling during screening. They obtain their food during two or more daily feeding periods by performing in operant (instrumental) and Pavlovian (classical) protocols, for which we have written protocol-control software and quasi-real-time data analysis and graphing software. The data analysis and graphing routines are written in a MATLAB-based language created to simplify greatly the analysis of large time-stamped behavioral and physiological event records and to preserve a full data trail from raw data through all intermediate analyses to the published graphs and statistics within a single data structure. The data-analysis code harvests the data several times a day and subjects it to statistical and graphical analyses, which are automatically stored in the "cloud" and on in-lab computers. Thus, the progress of individual mice is visualized and quantified daily. The data-analysis code talks to the protocol-control code, permitting the automated advance from protocol to protocol of individual subjects. The behavioral protocols implemented are matching, autoshaping, timed hopper-switching, risk assessment in timed hopper-switching, impulsivity measurement, and the circadian anticipation of food availability. Open-source protocol-control and data-analysis code makes the addition of new protocols simple. Eight test environments fit in a 48 in x 24 in x 78 in cabinet; two such cabinets (16 environments) may be

  10. 90/10 JP5/Synthesized ISO-Paraffin Specification and Fit-for-Purpose Test Results

    DTIC Science & Technology

    2014-06-11

    The minor discrepancies between these results are within the experimental error of the method and can be considered not significant. These results ...90/10 JP5/SYNTHESIZED ISO-PARAFFIN SPECIFICATION AND FIT-FOR-PURPOSE TEST RESULTS NAVAIR SYSCOM REPORT 441/14-010 11 June 2014 Prepared By...2 3.0 RESULTS & DISCUSSION

  11. Western and Mediterranean Dietary Patterns and Physical Activity and Fitness among Spanish Older Adults.

    PubMed

    Bibiloni, Maria Del Mar; Julibert, Alicia; Argelich, Emma; Aparicio-Ugarriza, Raquel; Palacios, Gonzalo; Pons, Antoni; Gonzalez-Gross, Marcela; Tur, Josep A

    2017-07-06

    Objectives: To assess prevailing food patterns, and its association with physical activity and fitness among Spanish older adults. Methods: Cross-sectional study in Spain, collecting data from a sample ( n = 380; 54% female) aged 55-80 years (men) and 60-80 years (women) with no previously documented cardiovascular disease. Body weight, body fat and waist circumference were assessed. Physical activity performed was measured using the Minnesota Leisure-time Physical Activity Questionnaire (LTPA). Physical fitness was assessed using a validated physical fitness test battery. Food consumption was assessed by a validated semi-quantitative food-frequency questionnaire. Factor analysis identified two major dietary food patterns: "Western" (WDP) and "Mediterranean" (MDP) dietary patterns. Results: Participants in MDP's fourth quartile were classified in the second (men) and third (men and women) tertile of LTPA. After adjusting for age, body fat, waist-to-height ratio, and METs, in both sexes, a negative significant association was found between 30-s Chair stand and 6-min walking test, a positive significant association was found between 30-m Gait speed and 8-foot Time Up-and-Go (except in men) tests with WDP. The 30-m Gait speed test was negatively associated with MDP in men. Conclusions: MDP is associated with more time spent on LTPA, and this association was independent of body composition and a fast gait speed in men. WDP is associated with slower gait speed and lower body strength, agility and aerobic endurance. MDP has protective effect on healthy physical fitness, and WDP may be a contributor to frailty.

  12. The Effect of a Physical Fitness Program on Low-Fit Children.

    ERIC Educational Resources Information Center

    Ignico, Arlene A.; Mahon, Anthony D.

    1995-01-01

    This study examined the effects of participation in an after school physical fitness program emphasizing aerobics on low-fit elementary students. Data were collected on four occasions. The program had a positive impact on field test measures but did not improve body fatness, cardiovascular responses to exercise, and blood lipid profiles. (SM)

  13. Physical fitness and job performance of firefighters.

    PubMed

    Rhea, Matthew R; Alvar, Brent A; Gray, Rayne

    2004-05-01

    Accurate correlations between a wide range of physical fitness measures and occupational demands are needed in order to identify specific fitness tests and training needs for firefighters. Twenty professional firefighters performed numerous fitness and job-related performance tests. Pearson product moment correlations were performed to identify the relationship between fitness components and job performance. Significant correlations (p <0.05) with job performance were identified for total fitness (r = -0.62), bench press strength (r = -0.66), hand grip strength (r = -0.71), bent-over row endurance (r = -0.61), bench press endurance (r = -0.73), shoulder press endurance (r = -0.71), bicep endurance (r = -0.69), squat endurance (r = -0.47), and 400-m sprint time (r = 0.79). It is apparent that firefighting taxes virtually all aspects of physical fitness. These data can help the exercise specialist choose appropriate tests and prescribe specific fitness programs for firefighters. Traditional firefighter exercise programs focusing mainly on cardiovascular fitness should be replaced with physical conditioning programs that address all components of fitness.

  14. Methods for CT automatic exposure control protocol translation between scanner platforms.

    PubMed

    McKenney, Sarah E; Seibert, J Anthony; Lamba, Ramit; Boone, John M

    2014-03-01

    An imaging facility with a diverse fleet of CT scanners faces considerable challenges when propagating CT protocols with consistent image quality and patient dose across scanner makes and models. Although some protocol parameters can comfortably remain constant among scanners (eg, tube voltage, gantry rotation time), the automatic exposure control (AEC) parameter, which selects the overall mA level during tube current modulation, is difficult to match among scanners, especially from different CT manufacturers. Objective methods for converting tube current modulation protocols among CT scanners were developed. Three CT scanners were investigated, a GE LightSpeed 16 scanner, a GE VCT scanner, and a Siemens Definition AS+ scanner. Translation of the AEC parameters such as noise index and quality reference mAs across CT scanners was specifically investigated. A variable-diameter poly(methyl methacrylate) phantom was imaged on the 3 scanners using a range of AEC parameters for each scanner. The phantom consisted of 5 cylindrical sections with diameters of 13, 16, 20, 25, and 32 cm. The protocol translation scheme was based on matching either the volumetric CT dose index or image noise (in Hounsfield units) between two different CT scanners. A series of analytic fit functions, corresponding to different patient sizes (phantom diameters), were developed from the measured CT data. These functions relate the AEC metric of the reference scanner, the GE LightSpeed 16 in this case, to the AEC metric of a secondary scanner. When translating protocols between different models of CT scanners (from the GE LightSpeed 16 reference scanner to the GE VCT system), the translation functions were linear. However, a power-law function was necessary to convert the AEC functions of the GE LightSpeed 16 reference scanner to the Siemens Definition AS+ secondary scanner, because of differences in the AEC functionality designed by these two companies. Protocol translation on the basis of

  15. Fuzz Testing of Industrial Network Protocols in Programmable Logic Controllers

    DTIC Science & Technology

    2017-12-01

    PLCs) are vital components in these cyber-physical systems. The industrial network protocols used to communicate between nodes in a control network...AB/RA) MicroLogix 1100 PLC through its implementation of EtherNet/IP, Common Industrial Protocol (CIP), and Programmable Controller Communication ...Commands (PCCC) communication protocols. This research also examines whether cross-generational vulnerabilities exist in the more advanced AB/RA

  16. Improving fitness of elite handball players: small-sided games vs. high-intensity intermittent training.

    PubMed

    Iacono, Antonio Dello; Eliakim, Alon; Meckel, Yoav

    2015-03-01

    The present study was designed to compare the effects of high-intensity intermittent training (HIIT) and small-sided games (SSGs) training on fitness variables of elite handball players. Eighteen highly trained players (mean age ± SD: 25.6 ± 0.5 years) were assigned to either HIIT or SSGs group training protocols twice per week for 8 weeks. The HIIT consisted of 12-24 × 15 seconds of high-intensity runs interspersed by 15 seconds of recovery. The SSGs training consisted of 3 against 3 small-sided handball games. Both training methods were matched for exercise duration and recovery at each training session. Before and after 8-week training, the following fitness variables were assessed-speed: 10- and 20-m sprint time, agility: handball agility specific test (HAST), upper arm strength: 1 repetition maximum (1RM) bench press test, lower limb power: counter-movement jump tests with (CMJarm) and without (CMJ) arm movement, and aerobic fitness (yo-yo intermittent recovery test level 1 [YYIRTL1]). Significant improvement was found in the YYIRTL1 (23.3 and 26.3%, respectively), 10-m sprint (2.3 and 4.1%, respectively) and 20-m sprint (2.1 and 4%, respectively), HAST (1.1 and 2.2%, respectively), 1RM bench press (6.8 and 12.3%, respectively), CMJ (7.4 and 10.8%, respectively), and CMJarm (6.4 and 8.9%, respectively) following training in both groups (p ≤ 0.05 for all). There was a significantly greater improvement in 10- and 20-m sprint, HAST, 1RM, CMJ, and CMJarm following the SSGs training compared with the HIIT (p ≤ 0.05 for all). These results indicated that both HIIT and SSGs are effective training methods for fitness development among elite adult handball players. However, SSGs training may be considered as the preferred training regimen for improving handball-specific fitness variables during the in-season period.

  17. Automating Security Protocol Analysis

    DTIC Science & Technology

    2004-03-01

    language that allows easy representation of pattern interaction. Using CSP, Lowe tests whether a protocol achieves authentication. In the case of...only to correctly code whatever protocol they intend to evaluate. The tool, OCaml 3.04 [1], translates the protocol into Horn clauses and then...model protocol transactions. One example of automated modeling software is Maude [19]. Maude was the intended language for this research, but Java

  18. Motor competence and physical fitness in adolescents.

    PubMed

    Gísladóttir, Ordís; Haga, Monika; Sigmundsson, Hermundur

    2014-01-01

    In this study we examined the relationship between physical fitness and motor competence in adolescents aged 15 to 16 years. A sample of 94 adolescents participated in the study. To test motor competence, the Movement Assessment Battery for Children-2 was used. Physical fitness was assessed using the following test items: standing broad jump, 20-m dash, reduced Cooper test, and sit-and-reach test. The results revealed a significant but weak relationship (0.248) between motor competence and physical fitness for the whole sample. More specifically, the correlation between the 2 variables was significant for girls (0.353) but not for boys (0.248). The relatively weak relationship between motor competence and physical fitness suggests that motor competence might not be critical in adolescents to maintain their physical fitness.

  19. Towards Risk-Based Test Protocols: Estimating the Contribution of Intensive Testing to the UK Bovine Tuberculosis Problem

    PubMed Central

    van Dijk, Jan

    2013-01-01

    Eradicating disease from livestock populations involves the balancing act of removing sufficient numbers of diseased animals without removing too many healthy individuals in the process. As ever more tests for bovine tuberculosis (BTB) are carried out on the UK cattle herd, and each positive herd test triggers more testing, the question arises whether ‘false positive’ results contribute significantly to the measured BTB prevalence. Here, this question is explored using simple probabilistic models of test behaviour. When the screening test is applied to the average UK herd, the estimated proportion of test-associated false positive new outbreaks is highly sensitive to small fluctuations in screening test specificity. Estimations of this parameter should be updated as a priority. Once outbreaks have been confirmed in screening-test positive herds, the following rounds of intensive testing with more sensitive, albeit less specific, tests are highly likely to remove large numbers of false positive animals from herds. Despite this, it is unlikely that significantly more truly infected animals are removed. BTB test protocols should become based on quantified risk in order to prevent the needless slaughter of large numbers of healthy animals. PMID:23717517

  20. Comparison of Quantitative Antifungal Testing Methods for Textile Fabrics.

    PubMed

    Imoto, Yasuo; Seino, Satoshi; Nakagawa, Takashi; Yamamoto, Takao A

    2017-01-01

     Quantitative antifungal testing methods for textile fabrics under growth-supportive conditions were studied. Fungal growth activities on unfinished textile fabrics and textile fabrics modified with Ag nanoparticles were investigated using the colony counting method and the luminescence method. Morphological changes of the fungi during incubation were investigated by microscopic observation. Comparison of the results indicated that the fungal growth activity values obtained with the colony counting method depended on the morphological state of the fungi on textile fabrics, whereas those obtained with the luminescence method did not. Our findings indicated that unique characteristics of each testing method must be taken into account for the proper evaluation of antifungal activity.