Mellen, Samantha; de Ferrars, Maria; Chapman, Claire; Bevan, Sarah; Turvill, James; Turnock, Daniel
2018-01-01
Background Faecal immunochemical testing is increasingly being used to triage symptomatic patients for suspected colorectal cancer. However, there are limited data on the effect of preanalytical factors on faecal haemoglobin when measured by faecal immunochemical testing. The aim of this work was to evaluate the stability of faecal haemoglobin in faeces and to compare two methods of faecal haemoglobin sampling for faecal immunochemical testing. Methods Six patients provided faeces for faecal haemoglobin measurement which were transferred into specialized collection devices at baseline and at 1, 2, 3 and 7 days after storage at either room temperature or 4°C. A total of 137 patients returned both faeces transferred into the specialized collection device and faeces in a standard collection pot. A quantitative immunoturbidometric method was used to measure faecal haemoglobin and results were compared categorically. Discrepant results were assessed against diagnosis. Results Faecal haemoglobin concentration declined rapidly within a day of storage at room temperature but results remained ≥10 μg Hb/g faeces in 5/6 patients after two days. A faecal haemoglobin result ≥10 μg Hb/g faeces was obtained in 4/6 patients after storage for seven days at 4°C. Results obtained when patients used specialized collection devices were significantly different from results obtained when faeces was transferred into the specialized collection device in the laboratory. Conclusion There is considerable heterogeneity in the sample stability of faecal haemoglobin; therefore, samples should be transferred rapidly into specialized collection devices to prevent false-negative results. Use of collection devices by patients can lead to false-positive results compared with their use in a laboratory.
Telford, Jennifer; Gentile, Laura; Gondara, Lovedeep; McGahan, Colleen; Coldman, Andrew
2016-01-01
British Columbia undertook a colorectal cancer screening pilot program in 3 communities. Our objective was to assess the performance of 2-specimen fecal immunochemical testing in the detection of colorectal neoplasms in this population-based screening program. A prospective cohort of asymptomatic, average-risk people aged 50 to 74 years completed 2 quantitative fecal immunochemical tests every 2 years, with follow-up colonoscopy if the result of either test was positive. Participant demographics, fecal immunochemical test results, colonoscopy quality indicators and pathology results were recorded. Non-screen-detected colorectal cancer that developed in program participants was identified through review of data from the BC Cancer Registry. A total of 16 234 people completed a first round of fecal immunochemical testing, with a positivity rate of 8.6%; 5378 (86.0% of eligible participants) completed a second round before the end of the pilot program, with a positivity rate of 6.7%. Of the 1756 who had a positive test result, 1555 (88.6%) underwent colonoscopy. The detection rate of colorectal cancer was 3.5 per 1000 participants. The positive predictive value of the fecal immunochemical test was 4.9% (95% confidence interval [CI] 3.8%-6.0%) for colorectal cancer, 35.0% (95% CI 32.5%-37.2%) for high-risk polyps and 62.0% (95% CI 59.6%-64.4%) for all neoplasms. The number needed to screen was 283 to detect 1 cancer, 40 to detect 1 high-risk polyp and 22 to detect any neoplasm. Screening every 2 years with a 2-specimen fecal immunochemical test surpassed the current benchmark for colorectal cancer detection in population-based screening. This study has implications for other jurisdictions planning colorectal cancer screening programs.
Sirisinha, Stitaya; Allen, Peter Z.
1965-01-01
Sirishinha, Stitaya (University of Rochester School of Medicine and Dentistry, Rochester, N.Y.), and Peter Z. Allen. Immunochemical studies on α-amylase. III. Immunochemical relationships among amylases from various microorganisms. J. Bacteriol. 90:1120–1128. 1965.—Immunochemical relationships among amylases obtained from a selected group of microorganisms were examined, and a cross-reaction was detected between the α-amylases of Bacillus stearothermophilus and B. subtilis. Immunodiffusion and quantitative precipitin studies, as well as cross-neutralization tests, indicate that B. stearothermophilus α-amylase reacts with a portion of antibody present in antisera to crystalline B. subtilis α-amylase. Amylases from these two species thus have some aspects of structure in common. Limited data obtained by immunodiffusion suggest that groupings which confer cross-reactivity to the B. stearothermophilus enzyme are lost after exposure to mercaptoethanol in the presence of ethylenediamine-tetraacetate, followed by treatment with iodoacetamide. With the antisera employed and within the concentration range examined, no immunochemical cross-reaction was observed among amylases from Aspergillus oryzae, B. subtilis, B. polymyxa, B. macerans, Pseudomonas saccharophila, and Euglena sanguinis. Immunoelectrophoresis of partially purified B. stearothermophilus α-amylase by use of antiserum to the crude enzyme, together with localization of amylase activity in immunoelectrophoretic plates, suggests that B. stearothermophilus α-amylase is antigenic in the rabbit. Images PMID:5847799
A Label-Free, Quantitative Fecal Hemoglobin Detection Platform for Colorectal Cancer Screening
Soraya, Gita V.; Nguyen, Thanh C.; Abeyrathne, Chathurika D.; Huynh, Duc H.; Chan, Jianxiong; Nguyen, Phuong D.; Nasr, Babak; Chana, Gursharan; Kwan, Patrick; Skafidas, Efstratios
2017-01-01
The early detection of colorectal cancer is vital for disease management and patient survival. Fecal hemoglobin detection is a widely-adopted method for screening and early diagnosis. Fecal Immunochemical Test (FIT) is favored over the older generation chemical based Fecal Occult Blood Test (FOBT) as it does not require dietary or drug restrictions, and is specific to human blood from the lower digestive tract. To date, no quantitative FIT platforms are available for use in the point-of-care setting. Here, we report proof of principle data of a novel low cost quantitative fecal immunochemical-based biosensor platform that may be further developed into a point-of-care test in low-resource settings. The label-free prototype has a lower limit of detection (LOD) of 10 µg hemoglobin per gram (Hb/g) of feces, comparable to that of conventional laboratory based quantitative FIT diagnostic systems. PMID:28475117
Quantitation of Protein Carbonylation by Dot Blot
Wehr, Nancy B.; Levine, Rodney L.
2012-01-01
Protein carbonylation is the most commonly used measure of oxidative modification of proteins. It is frequently measured spectrophotometrically or immunochemically by derivatizing proteins with the classical carbonyl reagent, 2,4-dinitrophenylhydrazine. We developed an immunochemical dot blot method for quantitation of protein carbonylation in homogenates or purified proteins. Dimethyl sulfoxide was employed as the solvent because it very efficiently extracts proteins from tissues and keeps them soluble. It also readily dissolves 2,4-dinitrophenylhydrazine and wets PVDF membranes. The detection limit is 0.19 ± 0.04 pmol carbonyl. Sixty ng protein is sufficient to measure protein carbonyl content. This level of sensitivity allowed measurement of protein carbonylation in individual Drosophila. PMID:22326366
Quantitation of protein carbonylation by dot blot.
Wehr, Nancy B; Levine, Rodney L
2012-04-15
Protein carbonylation is the most commonly used measure of oxidative modification of proteins. It is frequently measured spectrophotometrically or immunochemically by derivatizing proteins with the classical carbonyl reagent, 2,4-dinitrophenylhydrazine. We developed an immunochemical dot blot method for quantitation of protein carbonylation in homogenates or purified proteins. Dimethyl sulfoxide was employed as the solvent because it very efficiently extracts proteins from tissues and keeps them soluble. It also readily dissolves 2,4-dinitrophenylhydrazine and wets polyvinylidene difluoride (PVDF) membranes. The detection limit is 0.19 ± 0.04 pmol of carbonyl, and 60 ng of protein is sufficient to measure protein carbonyl content. This level of sensitivity allowed measurement of protein carbonylation in individual Drosophila. Copyright © 2012 Elsevier Inc. All rights reserved.
ELEGANT ENVIRONMENTAL IMMUNOASSAYS
Immunochemical methods are based on selective antibodies directed to a particular target analyte. The specific binding between antibody and analyte can be used for detection and quantitation. Methods such as the enzyme-linked immunosorbent assay (ELISA) can provide a sensitiv...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wynn, S.R.; Swanson, M.C.; Reed, C.E.
1988-07-01
With an immunochemical method, we analyzed outdoor air samples during a 3-year period for concentrations of the predominant local species of moth, Pseudaletia unipuncta (Haworth). Airborne particulates were collected on fiberglass filter sheets with an Accu-Vol sampler located 1.5 m above ground on the southeastern Minnesota prairie. Filter eluates analyzed by RIA inhibition contained concentrations of moth protein peaking in June and August to September of each year, with levels comparable to reported immunochemically measured levels of pollen and mold allergens. These peaks also corresponded with total numbers of moths captured in light traps. Moth-allergen activity was distributed in particlemore » sizes ranging from 0.8 to greater than 4.1 micron when sized samples were obtained by use of an Andersen cascade impaction head. By RIA inhibition, there was cross-reactivity between P. unipuncta and insects of different genera, families, and orders, but not with pollens or molds. Forty-five percent of 257 patients with immediate positive skin tests to common aeroallergens had positive skin tests to one or more commercially available whole body insect extracts. Of 120 patients with allergic rhinitis believed to be primarily caused by ragweed sensitivity, 5% also had elevated specific IgE to moths. We conclude that airborne concentrations of Lepidoptera can be measured immunochemically and that moths may be a seasonal allergen in the United States.« less
21 CFR 866.5180 - Fecal calprotectin immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... immunological test system is an in vitro diagnostic device that consists of reagents used to quantitatively measure, by immunochemical techniques, fecal calprotectin in human stool specimens. The device is intended forin vitro diagnostic use as an aid in the diagnosis of inflammatory bowel diseases (IBD), specifically...
Immunochemical Studies on Selected Marine Toxins
1993-05-31
6) Critical evaluation of established immunoassays was made through analysis of various naturally -occurring MCYST containing samples. We found that...hepatopancreas of toxic clams rather than the soft tissues. Microcystin could also be detected by ELISA in naturally -occurring algae bloom samples that...antibody against MCYST 13 7. Other immunochemical studies on MCYST 13 a. Analysis of MCYST in algae and various samples collected from naturally -occurring
21 CFR 866.6030 - AFP-L3% immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... system is an in vitro device that consists of reagents and an automated instrument used to quantitatively measure, by immunochemical techniques, AFP and AFP-L3 subfraction in human serum. The device is intended for in vitro diagnostic use as an aid in the risk assessment of patients with chronic liver disease...
Guaiac and immunochemical tests for faecal occult blood in colorectal cancer screening.
Castiglione, G.; Grazzini, G.; Ciatto, S.
1992-01-01
Seven hundred and eighty-six subjects spontaneously referring to our Center performed two guaiac (Rehydrated Hemoccult II (R.HO), and Hemoccult Sensa (HO S.)), and two immunochemical (OC Hemodia (Hdia) and Hemeselect (Hsel)) faecal occult blood tests on three consecutive faecal determinations. The positivity rates of 3 day R.HO, HO S., Hdia, and Hsel were 4.8%, 5.6%, 8.4% and 11.2% respectively. One hundred and thirty-five of the 150 subjects with at least one positive test completed the diagnostic work-up. Cancer was detected in three subjects and adenomas in 15. Three-day specificity estimates of R.HO, HO S., Hdia and Hsel in the overall series were 96.1%, 96.0%, 93.8% and 91.2% respectively, the differences between guaiac and immunochemical tests being significant. Corresponding values of specificity as determined on the first faecal sample only in the overall series were 98.1%, 98.3%, 96.1% and 94.9% respectively. No significant difference in specificity is evident when 3-day guaiac tests are compared to 1-day immunochemical ones. Three-day immunochemical testing is not recommended for screening purposes due to its very low specificity. Nevertheless, 1-day immunochemical testing is almost as specific as 3-day guaiac testing. A preliminary estimate of colonic neoplasms detection rates shows no difference as well. The benefit of 1-day testing on screening acceptability is evident, but the impact on sensitivity should be evaluated in a screening situation with a proper study design and a larger sample size. PMID:1616868
Homogeneous Immunoassays: Historical Perspective and Future Promise
NASA Astrophysics Data System (ADS)
Ullman, Edwin F.
1999-06-01
The founding and growth of Syva Company is examined in the context of its leadership role in the development of homogeneous immunoassays. The simple mix and read protocols of these methods offer advantages in routine analytical and clinical applications. Early homogeneous methods were based on insensitive detection of immunoprecipitation during antigen/antibody binding. The advent of reporter groups in biology provided a means of quantitating immunochemical binding by labeling antibody or antigen and physically separating label incorporated into immune complexes from free label. Although high sensitivity was achieved, quantitative separations were experimentally demanding. Only when it became apparent that reporter groups could provide information, not only about the location of a molecule but also about its microscopic environment, was it possible to design practical non-separation methods. The evolution of early homogenous immunoassays was driven largely by the development of improved detection strategies. The first commercial spin immunoassays, developed by Syva for drug abuse testing during the Vietnam war, were followed by increasingly powerful methods such as immunochemical modulation of enzyme activity, fluorescence, and photo-induced chemiluminescence. Homogeneous methods that quantify analytes at femtomolar concentrations within a few minutes now offer important new opportunities in clinical diagnostics, nucleic acid detection and drug discovery.
Sekiguchi, Masau; Igarashi, Ataru; Matsuda, Takahisa; Matsumoto, Minori; Sakamoto, Taku; Nakajima, Takeshi; Kakugawa, Yasuo; Yamamoto, Seiichiro; Saito, Hiroshi; Saito, Yutaka
2016-02-01
There have been few cost-effectiveness analyses of population-based colorectal cancer screening in Japan, and there is no consensus on the optimal use of total colonoscopy and the fecal immunochemical test for colorectal cancer screening with regard to cost-effectiveness and total colonoscopy workload. The present study aimed to examine the cost-effectiveness of colorectal cancer screening using Japanese data to identify the optimal use of total colonoscopy and fecal immunochemical test. We developed a Markov model to assess the cost-effectiveness of colorectal cancer screening offered to an average-risk population aged 40 years or over. The cost, quality-adjusted life-years and number of total colonoscopy procedures required were evaluated for three screening strategies: (i) a fecal immunochemical test-based strategy; (ii) a total colonoscopy-based strategy; (iii) a strategy of adding population-wide total colonoscopy at 50 years to a fecal immunochemical test-based strategy. All three strategies dominated no screening. Among the three, Strategy 1 was dominated by Strategy 3, and the incremental cost per quality-adjusted life-years gained for Strategy 2 against Strategies 1 and 3 were JPY 293 616 and JPY 781 342, respectively. Within the Japanese threshold (JPY 5-6 million per QALY gained), Strategy 2 was the most cost-effective, followed by Strategy 3; however, Strategy 2 required more than double the number of total colonoscopy procedures than the other strategies. The total colonoscopy-based strategy could be the most cost-effective for population-based colorectal cancer screening in Japan. However, it requires more total colonoscopy procedures than the other strategies. Depending on total colonoscopy capacity, the strategy of adding total colonoscopy for individuals at a specified age to a fecal immunochemical test-based screening may be an optimal solution. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Lee, Ji-Yun; Kim, Chang Jong
2010-01-01
Egg allergy is one of the most common food allergies in both adults and children, and foods including eggs and their byproducts should be declared under food allergen labeling policies in industrial countries. Therefore, to develop and validate a sensitive and specific method to detect hidden egg allergens in foods, we compared immunochemical, DNA-based, and proteomic methods for detecting egg allergens in foods using egg allergen standards such as egg whole protein, egg white protein, egg yolk protein, ovomucoid, ovalbumin, ovotransferrin, lysozyme, and alpha-livetin. Protein-based immunochemical methods, including ELISA as an initial screening quantitative analysis and immunoblotting as a final confirmatory qualitative analysis, were very sensitive and specific in detecting potentially allergenic egg residues in processed foods in trace amounts. In contrast, the proteomics-based, matrix-assisted laser desorption/ionization time-of-flight MS and LC-tandem quadrupole time-of-flight MS methods were not able to detect some egg allergens, such as ovomucoid, because of its nondenaturing property under urea and trypsin. The DNA-based PCR method could not distinguish between egg and chicken meat because it is tissue-nonspecific. In further studies for the feasibility of these immunochemical methods on 100 real raw dietary samples, four food samples without listed egg ingredients produced a positive response by ELISA, but exhibited negative results by immunoblotting.
Westwood, Marie; Corro Ramos, Isaac; Lang, Shona; Luyendijk, Marianne; Zaim, Remziye; Stirk, Lisa; Al, Maiwenn; Armstrong, Nigel; Kleijnen, Jos
2017-05-01
Colorectal cancer (CRC) is the third most common cancer in the UK. Presenting symptoms that can be associated with CRC usually have another explanation. Faecal immunochemical tests (FITs) detect blood that is not visible to the naked eye and may help to select patients who are likely to benefit from further investigation. To assess the effectiveness of FITs [OC-Sensor (Eiken Chemical Co./MAST Diagnostics, Tokyo, Japan), HM-JACKarc (Kyowa Medex/Alpha Laboratories Ltd, Tokyo, Japan), FOB Gold (Sentinel/Sysmex, Sentinel Diagnostics, Milan, Italy), RIDASCREEN Hb or RIDASCREEN Hb/Hp complex (R-Biopharm, Darmstadt, Germany)] for primary care triage of people with low-risk symptoms. Twenty-four resources were searched to March 2016. Review methods followed published guidelines. Summary estimates were calculated using a bivariate model or a random-effects logistic regression model. The cost-effectiveness analysis considered long-term costs and quality-adjusted life-years (QALYs) that were associated with different faecal occult blood tests and direct colonoscopy referral. Modelling comprised a diagnostic decision model, a Markov model for long-term costs and QALYs that were associated with CRC treatment and progression, and a Markov model for QALYs that were associated with no CRC. We included 10 studies. Using a single sample and 10 µg Hb/g faeces threshold, sensitivity estimates for OC-Sensor [92.1%, 95% confidence interval (CI) 86.9% to 95.3%] and HM-JACKarc (100%, 95% CI 71.5% to 100%) indicated that both may be useful to rule out CRC. Specificity estimates were 85.8% (95% CI 78.3% to 91.0%) and 76.6% (95% CI 72.6% to 80.3%). Triage using FITs could rule out CRC and avoid colonoscopy in approximately 75% of symptomatic patients. Data from our systematic review suggest that 22.5-93% of patients with a positive FIT and no CRC have other significant bowel pathologies. The results of the base-case analysis suggested minimal difference in QALYs between all of the strategies; no triage (referral straight to colonoscopy) is the most expensive. Faecal immunochemical testing was cost-effective (cheaper and more, or only slightly less, effective) compared with no triage. Faecal immunochemical testing was more effective and costly than guaiac faecal occult blood testing, but remained cost-effective at a threshold incremental cost-effectiveness ratio of £30,000. The results of scenario analyses did not differ substantively from the base-case. Results were better for faecal immunochemical testing when accuracy of the guaiac faecal occult blood test (gFOBT) was based on studies that were more representative of the correct population. Only one included study evaluated faecal immunochemical testing in primary care; however, all of the other studies evaluated faecal immunochemical testing at the point of referral. Further, validation data for the Faecal haemoglobin, Age and Sex Test (FAST) score, which includes faecal immunochemical testing, showed no significant difference in performance between primary and secondary care. There were insufficient data to adequately assess FOB Gold, RIDASCREEN Hb or RIDASCREEN Hb/Hp complex. No study compared FIT assays, or FIT assays versus gFOBT; all of the data included in this assessment refer to the clinical effectiveness of individual FIT methods and not their comparative effectiveness. Faecal immunochemical testing is likely to be a clinically effective and cost-effective strategy for triaging people who are presenting, in primary care settings, with lower abdominal symptoms and who are at low risk for CRC. Further research is required to confirm the effectiveness of faecal immunochemical testing in primary care practice and to compare the performance of different FIT assays. This study is registered as PROSPERO CRD42016037723. The National Institute for Health Research Health Technology Assessment programme.
Immunochemical faecal occult blood test for colorectal cancer screening: a systematic review.
Syful Azlie, M F; Hassan, M R; Junainah, S; Rugayah, B
2015-02-01
A systematic review on the effectiveness and costeffectiveness of Immunochemical faecal occult IFOBT for CRC screening was carried out. A total of 450 relevant titles were identified, 41 abstracts were screened and 18 articles were included in the results. There was fair level of retrievable evidence to suggest that the sensitivity and specificity of IFOBT varies with the cut-off point of haemoglobin, whereas the diagnostic accuracy performance was influenced by high temperature and haemoglobin stability. A screening programme using IFOBT can be effective for prevention of advanced CRC and reduced mortality. There was also evidence to suggest that IFOBT is cost-effective in comparison with no screening, whereby a two-day faecal collection method was found to be costeffective as a means of screening for CRC. Based on the review, quantitative IFOBT method can be used in Malaysia as a screening test for CRC. The use of fully automated IFOBT assay would be highly desirable.
Saleh, Aljona; Stephanson, Niclas Nikolai; Granelli, Ingrid; Villén, Tomas; Beck, Olof
2012-11-15
In this study a rapid liquid chromatography-time-of-flight mass spectrometry method was developed, validated and applied in order to evaluate the potential of this technique for routine urine drug testing. Approximately 800 authentic patient samples were analyzed for amphetamines (amphetamine and methamphetamine), opiates (morphine, morphine-3-glucuronide, morphine-6-glucuronide, codeine and codeine-6-glucuronide) and buprenorphines (buprenorphine and buprenorphine-glucuronide) using immunochemical screening assays and mass spectrometry confirmation methods for comparison. The chromatographic application utilized a rapid gradient with high flow and a reversed phase column with 1.8 μm particles. Total analysis time was 4 min. The mass spectrometer operated with an electrospray interface in positive mode with a resolution power of >10,000 at m/z 956. The applied reporting limits were 100 ng/mL for amphetamines and opiates, and 5 ng/mL for buprenorphines, with lower limits of quantification were 2.8-41 ng/mL. Calibration curves showed a linear response with coefficients of correlation of 0.97-0.99. The intra- and interday imprecision in quantification at the reporting limits were <10% for all analytes but for buprenorphines <20%. Method validation data met performance criteria for a qualitative and quantitative method. The liquid chromatography-time-of-flight mass spectrometry method was found to be more selective than the immunochemical method by producing lower rates of false positives (0% for amphetamines and opiates; 3.2% for buprenorphines) and negatives (1.8% for amphetamines; 0.6% for opiates; 0% for buprenorphines). The overall agreement between the two screening methods was between 94.2 and 97.4%. Comparison of data with the confirmation (LC-MS) results for all individual 9 analytes showed that most deviating results were produced in samples with low levels of analytes. False negatives were mainly related to failure of detected peak to meet mass accuracy criteria (±20 mDa). False positives was related to presence of interfering peaks meeting mass accuracy and retention time criteria and occurred mainly at low levels. It is concluded that liquid chromatography-time-of-flight mass spectrometry has potential both as a complement and as replacement of immunochemical screening assays. Copyright © 2012 Elsevier B.V. All rights reserved.
Levin, Theodore R; Corley, Douglas A; Jensen, Christopher D; Marks, Amy R; Zhao, Wei K; Zebrowski, Alexis M; Quinn, Virginia P; Browne, Lawrence W; Taylor, William R; Ahlquist, David A; Lidgard, Graham P; Berger, Barry M
2017-03-01
Fecal immunochemical test (FIT) screening detects most asymptomatic colorectal cancers. Combining FIT screening with stool-based genetic biomarkers increases sensitivity for cancer, but whether DNA biomarkers (biomarkers) differ for cancers detected versus missed by FIT screening has not been evaluated in a community-based population. To evaluate tissue biomarkers among Kaiser Permanente Northern California patients diagnosed with colorectal cancer within 2 years after FIT screening. FIT-negative and FIT-positive colorectal cancer patients 50-77 years of age were matched on age, sex, and cancer stage. Adequate DNA was isolated from paraffin-embedded specimens in 210 FIT-negative and 211 FIT-positive patients. Quantitative allele-specific real-time target and signal amplification assays were performed for 7 K-ras mutations and 10 aberrantly methylated DNA biomarkers (NDRG4, BMP3, SFMBT2_895, SFMBT2_896, SFMBT2_897, CHST2_7890, PDGFD, VAV3, DTX1, CHST2_7889). One or more biomarkers were found in 414 of 421 CRCs (98.3%). Biomarker expression was not associated with FIT status, with the exception of higher SFMBT2_897 expression in FIT-negative (194 of 210; 92.4%) than in FIT-positive cancers (180 of 211; 85.3%; p = 0.02). There were no consistent differences in biomarker expression by FIT status within age, sex, stage, and cancer location subgroups. The biomarkers of a currently in-use multi-target stool DNA test (K-ras, NDRG4, and BMP3) and eight newly characterized methylated biomarkers were commonly expressed in tumor tissue specimens, independent of FIT result. Additional study using stool-based testing with these new biomarkers will allow assessment of sensitivity, specificity, and clinical utility.
[Immunochemistry of eukaryotic ribosomes].
Lopaczyński, W; Gałasiński, W
1990-01-01
Immunochemical investigations of ribosomes should correlate with basic knowledge of the function, structure and activity of organelles in the cell processes. Our paper presents data of immunochemical methods used to determine the structure, function and differences of ribosomes. We present the usefulness of immunochemical methods to test human ribosomes, diagnosis and therapy of many diseases.
Targeted Quantitation of Proteins by Mass Spectrometry
2013-01-01
Quantitative measurement of proteins is one of the most fundamental analytical tasks in a biochemistry laboratory, but widely used immunochemical methods often have limited specificity and high measurement variation. In this review, we discuss applications of multiple-reaction monitoring (MRM) mass spectrometry, which allows sensitive, precise quantitative analyses of peptides and the proteins from which they are derived. Systematic development of MRM assays is permitted by databases of peptide mass spectra and sequences, software tools for analysis design and data analysis, and rapid evolution of tandem mass spectrometer technology. Key advantages of MRM assays are the ability to target specific peptide sequences, including variants and modified forms, and the capacity for multiplexing that allows analysis of dozens to hundreds of peptides. Different quantitative standardization methods provide options that balance precision, sensitivity, and assay cost. Targeted protein quantitation by MRM and related mass spectrometry methods can advance biochemistry by transforming approaches to protein measurement. PMID:23517332
Targeted quantitation of proteins by mass spectrometry.
Liebler, Daniel C; Zimmerman, Lisa J
2013-06-04
Quantitative measurement of proteins is one of the most fundamental analytical tasks in a biochemistry laboratory, but widely used immunochemical methods often have limited specificity and high measurement variation. In this review, we discuss applications of multiple-reaction monitoring (MRM) mass spectrometry, which allows sensitive, precise quantitative analyses of peptides and the proteins from which they are derived. Systematic development of MRM assays is permitted by databases of peptide mass spectra and sequences, software tools for analysis design and data analysis, and rapid evolution of tandem mass spectrometer technology. Key advantages of MRM assays are the ability to target specific peptide sequences, including variants and modified forms, and the capacity for multiplexing that allows analysis of dozens to hundreds of peptides. Different quantitative standardization methods provide options that balance precision, sensitivity, and assay cost. Targeted protein quantitation by MRM and related mass spectrometry methods can advance biochemistry by transforming approaches to protein measurement.
A proposal to standardize reporting units for fecal immunochemical tests for hemoglobin.
Fraser, Callum G; Allison, James E; Halloran, Stephen P; Young, Graeme P
2012-06-06
Fecal immunochemical tests for hemoglobin are replacing traditional guaiac fecal occult blood tests in population screening programs for many reasons. However, the many available fecal immunochemical test devices use a range of sampling methods, differ with regard to hemoglobin stability, and report hemoglobin concentrations in different ways. The methods for sampling, the mass of feces collected, and the volume and characteristics of the buffer used in the sampling device also vary among fecal immunochemical tests, making comparisons of test performance characteristics difficult. Fecal immunochemical test results may be expressed as the hemoglobin concentration in the sampling device buffer and, sometimes, albeit rarely, as the hemoglobin concentration per mass of feces. The current lack of consistency in units for reporting hemoglobin concentration is particularly problematic because apparently similar hemoglobin concentrations obtained with different devices can lead to very different clinical interpretations. Consistent adoption of an internationally accepted method for reporting results would facilitate comparisons of outcomes from these tests. We propose a simple strategy for reporting fecal hemoglobin concentration that will facilitate the comparison of results between fecal immunochemical test devices and across clinical studies. Such reporting is readily achieved by defining the mass of feces sampled and the volume of sample buffer (with confidence intervals) and expressing results as micrograms of hemoglobin per gram of feces. We propose that manufacturers of fecal immunochemical tests provide this information and that the authors of research articles, guidelines, and policy articles, as well as pathology services and regulatory bodies, adopt this metric when reporting fecal immunochemical test results.
Rapi, Stefano; Berardi, Margherita; Cellai, Filippo; Ciattini, Samuele; Chelazzi, Laura; Ognibene, Agostino; Rubeca, Tiziana
2017-07-24
Information on preanalytical variability is mandatory to bring laboratories up to ISO 15189 requirements. Fecal sampling is greatly affected by lack of harmonization in laboratory medicine. The aims of this study were to obtain information on the devices used for fecal sampling and to explore the effect of different amounts of feces on the results from the fecal immunochemical test for hemoglobin (FIT-Hb). Four commercial sample collection devices for quantitative FIT-Hb measurements were investigated. The volume of interest (VOI) of the probes was measured from diameter and geometry. Quantitative measurements of the mass of feces were carried out by gravimetry. The effects of an increased amount of feces on the analytical environment were investigated measuring the Hb values with a single analytical method. VOI was 8.22, 7.1 and 9.44 mm3 for probes that collected a target of 10 mg of feces, and 3.08 mm3 for one probe that targeted 2 mg of feces. The ratio between recovered and target amounts of devices ranged from 56% to 121%. Different changes in the measured Hb values were observed, in adding increasing amounts of feces in commercial buffers. The amounts of collected materials are related to the design of probes. Three out 4 manufacturers declare the same target amount using different sampling volumes and obtaining different amounts of collected materials. The introduction of a standard probes to reduce preanalytical variability could be an useful step for fecal test harmonization and to fulfill the ISO 15189 requirements.
Oat raw materials and bakery products - amino acid composition and celiac immunoreactivity.
Mickowska, Barbara; Litwinek, Dorota; Gambuś, Halina
2016-01-01
The aim of this study was to compare the biochemical and immunochemical properties of avenins in some special oat raw materials and additionally the possibility of using them as a raw material for the gluten-free bakery products. The compared oat raw materials were - oat flakes, commercial oat flours (including gluten-free oat flour) and residual oat flour, which is by-product of β-glucan preparation. Biochemical characteristic included amino acid compositions and SDS-PAGE profiles of extracted avenins. The immunochemical reactivity with polyclonal anti-gluten and monoclonal anti-gliadin antibodies was evaluated qualitatively and quantitatively by immunoblotting and ELISA methods. Additionally, experimental bakery products made of examined raw materials were assessed according to their suitability for the celiac patients' diet. The highest protein content was measured in the β-glucan preparation "Betaven" and gluten-free oat flour. Proteins of all materials are rich in glutamic and aspartic acid, leucine and arginine. Proportions of amino acids in avenins extracted from most of oat raw materials are similar, excluding gluten-free oat flour, which has a very low avenin content and proportions of individual amino acids are different. The SDS-PAGE protein pattern consisted of proteins with molecular weight of about 25-35 kDa. Polyclonal anti-gluten anti-body recognized all protein fractions of molecular weight higher than 20 kDa. Quantitative ELISA analysis shows that the majority of samples has a gliadin-like protein content within the range of 80-260 mg/kg, excluding gluten-free flours and corresponding bakery products. Altogether, β-glucan preparation has extremely high level of gliadin-like proteins. In the examined oat raw materials and foods the contents of immunoreactive amino acid sequences exceeded the limit of 20 mg/kg (considered as gluten-free) except for gluten-free flours (oat and the prepared mixture) and the bakery products based on gluten-free flours. Unfortunately, the rest of oat raw materials and products cannot be considered gluten-free.
Cha, Jae Myung; Suh, Mina; Kwak, Min Seob; Sung, Na Young; Choi, Kui Son; Park, Boyoung; Jun, Jae Kwan; Hwang, Sang-Hyun; Lee, Do-Hoon; Kim, Byung Chang; Lee, You Kyoung; Han, Dong Soo
2018-04-01
This study aimed to evaluate the impact of seasonal variations in climate on the performance of the fecal immunochemical test (FIT) in screening for colorectal cancer in the National Cancer Screening Program in Korea. Data were extracted from the National Cancer Screening Program databases for participants who underwent FIT between 2009 and 2010. We compared positivity rates, cancer detection rates, interval cancer rates, positive predictive value, sensitivity, and specificity for FIT during the spring, summer, fall, and winter seasons in Korea. In total, 4,788,104 FIT results were analyzed. FIT positivity rate was lowest during the summer months. In the summer, the positive predictive value of FIT was about 1.1 times (adjusted odds ratio (aOR) 1.08, 95% confidence interval (CI) 1.00-1.16) higher in the overall FIT group and about 1.3 times (aOR 1.29, 95% CI 1.10-1.50) higher in the quantitative FIT group, compared to those in the other seasons. Cancer detection rates, however, were similar regardless of season. Interval cancer risk was significantly higher in the summer for both the overall FIT group (aOR 1.16, 95% CI 1.07-1.27) and the quantitative FIT group (aOR 1.31, 95% CI 1.12-1.52). In addition, interval cancers in the rectum and distal colon were more frequently detected in the summer and autumn than in the winter. The positivity rate of FIT was lower in the summer, and the performance of the FIT screening program was influenced by seasonal variations in Korea. These results suggest that more efforts to reduce interval cancer during the summer are needed in population-based screening programs using FIT, particularly in countries with high ambient temperatures.
Immunochemical Methods for Quantitation of Vitamin B6
1981-09-30
pANk K:E:: Z P a . LIST OF FIGURES Page Figure 1. Synthesis of N-Carboxymethylpyridoxine 15 Figure 2. Pyridoxine and N- Substituted Derivatives 16...Pyridoxine Substituted in the 3 Position 23 Figure 6. Synthesis of as -Pyridoxylformic Acid and as - 25 Pyridoxylacetic Acid Figure 7. Fluorogenic Galactosides...CH20 (Vill) (X Figure 2. Pyridoxine and N- Substituted Derivatives 16 hinder the formation of quaternary salts (Kirpal, 1910).’" We found this to be true
Effect of oral anticoagulants on the outcome of faecal immunochemical test
Bujanda, L; Sarasqueta, C; Lanas, Á; Quintero, E; Cubiella, J; Hernandez, V; Morillas, J D; Perez-Fernández, T; Salas, D; Andreu, M; Carballo, F; Bessa, X; Portillo, I; Jover, R; Balaguer, F; Cosme, A; Castells, A
2014-01-01
Background: We aimed to evaluate whether oral anticoagulants (OACs) alter faecal immunochemical test (FIT) performance in average-risk colorectal cancer (CRC) screening. Methods: Individuals aged 50–69 years were invited to receive one FIT sample (cutoff 75 ng ml–1) between November 2008 and June 2011. Results: Faecal immunochemical test was positive in 9.3% (21 out of 224) of users of OAC and 6.2% (365 out of 5821) of non-users (P-trend=0.07). The positive predictive value (PPV) for advanced neoplasia (AN) in non-users was 50.4% vs 47.6% in users (odds ratio, 0.70; 95% CI, 0.3–1.8; P=0.5). The PPV for AN in OAC more antiplatelets (aspirin or clopidogrel) was 75% (odds ratio, 2; 95% CI, 0.4–10.8; P=0.4). Conclusions: Oral anticoagulant did not significantly modify the PPV for AN in this population-based colorectal screening program. The detection rate of advanced adenoma was higher in the combination OAC more antiplatelets. PMID:24496455
Genetic control of enzyme formation. Final technical report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mills, S. E.
1978-07-26
Research progress is reported on work on tryptophan biosynthesis in Euglena gracilis and higher plants. The experimental data provide an outline of the general evolution of the pathway. Structural analyses of the pathway proteins by quantitative immunochemical methods have been completed; this was done with the anthranilate synthase-1 phosphoribosyl transferase complex in Escherichia coli. An examination of the evolution, in the Enterobacteriaceae, of the enzyme activities anthranilate synthase and anthranilate-5-1 phosphoribosyl-1-pyrophosphate phosphoribosyltransferase has been begun. (ACR)
Primary care visit use after positive fecal immunochemical test for colorectal cancer screening.
Hillyer, Grace Clarke; Jensen, Christopher D; Zhao, Wei K; Neugut, Alfred I; Lebwohl, Benjamin; Tiro, Jasmin A; Kushi, Lawrence H; Corley, Douglas A
2017-10-01
For some patients, positive cancer screening test results can be a stressful experience that can affect future screening compliance and increase the use of health care services unrelated to medically indicated follow-up. Among 483,216 individuals aged 50 to 75 years who completed a fecal immunochemical test to screen for colorectal cancer at a large integrated health care setting between 2007 and 2011, the authors evaluated whether a positive test was associated with a net change in outpatient primary care visit use within the year after screening. Multivariable regression models were used to evaluate the relationship between test result group and net changes in primary care visits after fecal immunochemical testing. In the year after the fecal immunochemical test, use increased by 0.60 clinic visits for patients with true-positive results. The absolute change in visits was largest (3.00) among individuals with positive test results who were diagnosed with colorectal cancer, but significant small increases also were found for patients treated with polypectomy and who had no neoplasia (0.36) and those with a normal examination and no polypectomy performed (0.17). Groups of patients who demonstrated an increase in net visit use compared with the true-negative group included patients with true-positive results (odds ratio [OR], 1.60; 95% confidence interval [95% CI], 1.54-1.66), and positive groups with a colorectal cancer diagnosis (OR, 7.19; 95% CI, 6.12-8.44), polypectomy/no neoplasia (OR, 1.37; 95% CI, 1.27-1.48), and normal examination/no polypectomy (OR, 1.24; 95% CI, 1.18-1.30). Given the large size of outreach programs, these small changes can cumulatively generate thousands of excess visits and have a substantial impact on total health care use. Therefore, these changes should be included in colorectal cancer screening cost models and their causes investigated further. Cancer 2017;123:3744-3753. © 2017 American Cancer Society. © 2017 American Cancer Society.
Berchi, Célia; Guittet, Lydia; Bouvier, Véronique; Launoy, Guy
2010-01-01
Most industrialized countries, including France, have undertaken to generalize colorectal cancer screening using guaiac fecal occult blood tests (G-FOBT). However, recent researches demonstrate that immunochemical fecal occult blood tests (I-FOBT) are more effective than G-FOBT. Moreover, new generation I-FOBT benefits from a quantitative reading technique allowing the positivity threshold to be chosen, hence offering the best balance between effectiveness and cost. We aimed at comparing the cost and the clinical performance of one round of screening using I-FOBT at different positivity thresholds to those obtained with G-FOBT to determine the optimal cut-off for I-FOBT. Data were derived from an experiment conducted from June 2004 to December 2005 in Calvados (France) where 20,322 inhabitants aged 50-74 years performed both I-FOBT and G-FOBT. Clinical performance was assessed by the number of advanced tumors screened, including large adenomas and cancers. Costs were assessed by the French Social Security Board and included only direct costs. Screening using I-FOBT resulted in better health outcomes and lower costs than screening using G-FOBT for thresholds comprised between 75 and 93 ng/ml. I-FOBT at 55 ng/ml also offers a satisfactory alternative to G-FOBT, because it is 1.8-fold more effective than G-FOBT, without increasing the number of unnecessary colonoscopies, and at an extra cost of 2,519 euros per advanced tumor screened. The use of an automated I-FOBT at 75 ng/ml would guarantee more efficient screening than currently used G-FOBT. Health authorities in industrialized countries should consider the replacement of G-FOBT by an automated I-FOBT test in the near future.
Ibañez-Sanz, Gemma; Garcia, Montse; Milà, Núria; Rodríguez-Moranta, Francisco; Binefa, Gemma; Gómez-Matas, Javier; Benito, Llúcia; Padrol, Isabel; Barenys, Mercè; Moreno, Victor
2017-09-01
The aim of this study was to analyse false-negative (FN) results of the faecal immunochemical test (FIT) and its determinants in a colorectal cancer screening programme in Catalonia. We carried out a cross-sectional study among 218 screenees with a negative FIT result who agreed to undergo a colonoscopy. A false-negative result was defined as the detection, at colonoscopy, of intermediate/high-risk polyps or colorectal cancer in a patient with a previous negative FIT (<20 µgHb/g). Multivariate logistic regression models were constructed to identify sociodemographic (sex, age) and screening variables (quantitative faecal haemoglobin, colonoscopy findings) related to FN results. Adjusted odds ratios and their 95% confidence intervals were estimated. There were 15.6% FN FIT results. Faecal haemoglobin was undetected in 45.5% of these results and was below 4 µgHb/g in 94.0% of the individuals with a FN result. About 60% of the lesions were located in the proximal colon, whereas the expected percentage was 30%. Decreasing the positivity threshold of FIT does not increase the detection rate of advanced neoplasia, but may increase the costs and potential adverse effects.
Rodia, Maria Teresa; Solmi, Rossella; Pasini, Francesco; Nardi, Elena; Mattei, Gabriella; Ugolini, Giampaolo; Ricciardiello, Luigi; Strippoli, Pierluigi; Miglio, Rossella; Lauriola, Mattia
2018-06-01
A noninvasive blood test for the early detection of colorectal cancer (CRC) is highly required. We evaluated a panel of 4 mRNAs as putative markers of CRC. We tested LGALS4, CEACAM6, TSPAN8, and COL1A2, referred to as the CELTiC panel, using quantitative reverse transcription polymerase chain reaction, on subjects with positive fecal immunochemical test (FIT) results and undergoing colonoscopy. Using a nonparametric test and multinomial logistic model, FIT-positive subjects were compared with CRC patients and healthy individuals. All the genes of the CELTiC panel displayed statistically significant differences between the healthy subjects (n = 67), both low-risk (n = 36) and high-risk/CRC (n = 92) subjects, and those in the negative-colonoscopy, FIT-positive group (n = 36). The multinomial logistic model revealed LGALS4 was the most powerful marker discriminating the 4 groups. When assessing the diagnostic values by analysis of the areas under the receiver operating characteristic curves (AUCs), the CELTiC panel reached an AUC of 0.91 (sensitivity, 79%; specificity, 94%) comparing normal subjects to low-risk subjects, and 0.88 (sensitivity, 75%; specificity, 87%) comparing normal and high-risk/CRC subjects. The comparison between the normal subjects and the negative-colonoscopy, FIT-positive group revealed an AUC of 0.93 (sensitivity, 82%; specificity, 97%). The CELTiC panel could represent a useful tool for discriminating subjects with positive FIT findings and for the early detection of precancerous adenomatous lesions and CRC. Copyright © 2017 Elsevier Inc. All rights reserved.
Cost-effectiveness analysis of a quantitative immunochemical test for colorectal cancer screening.
Wilschut, Janneke A; Hol, Lieke; Dekker, Evelien; Jansen, Jan B; Van Leerdam, Monique E; Lansdorp-Vogelaar, Iris; Kuipers, Ernst J; Habbema, J Dik F; Van Ballegooijen, Marjolein
2011-11-01
Two European randomized trials (N = 30,000) compared guaiac fecal occult blood testing with quantitative fecal immunochemical testing (FIT) and showed better attendance rates and test characteristics for FIT. We aimed to identify the most cost-effective FIT cutoff level for referral to colonoscopy based on data from these trials and allowing for differences in screening ages. We used the validated MIcrosimulation SCreening ANalysis (MISCAN)-Colon microsimulation model to estimate costs and effects of different screening strategies for FIT cutoff levels of 50, 75, 100, 150, and 200 ng/mL hemoglobin. For each cutoff level, screening strategies were assessed with various age ranges and screening intervals. We assumed sufficient colonoscopy capacity for all strategies. At all cost levels, FIT screening was most effective with the 50 ng/mL cutoff level. The incremental cost-effectiveness ratio of biennial screening between ages 55 and 75 years using FIT at 50 ng/mL, for example, was 3900 euro per life year gained. Annual screening had an incremental cost-effectiveness ratio of 14,900 euro per life year gained, in combination with a wider age range (between ages 45 and 80 years). In the sensitivity analysis, 50 ng/mL remained the preferred cutoff level. FIT screening is more cost-effective at a cutoff level of 50 ng/mL than at higher cutoff levels. This supports the recommendation to use FIT at a cutoff level of 50 ng/mL, which is considerably lower than the values used in current practice. Copyright © 2011 AGA Institute. Published by Elsevier Inc. All rights reserved.
IMMUNOCHEMICAL APPLICATIONS IN ENVIRONMENTAL SCIENCE
Immunochemical methods are based on selective antibodies combining with a particular target analyte or analyte group. The specific binding between antibody and analyte can be used to detect environmental contaminants in a variety of sample matrixes. Immunoassay methods provide ...
Symonds, Erin L; Cole, Stephen R; Bastin, Dawn; Fraser, Robert Jl; Young, Graeme P
2017-12-01
Objectives Faecal immunochemical test accuracy may be adversely affected when samples are exposed to high temperatures. This study evaluated the effect of two sample collection buffer formulations (OC-Sensor, Eiken) and storage temperatures on faecal haemoglobin readings. Methods Faecal immunochemical test samples returned in a screening programme and with ≥10 µg Hb/g faeces in either the original or new formulation haemoglobin stabilizing buffer were stored in the freezer, refrigerator, or at room temperature (22℃-24℃), and reanalysed after 1-14 days. Samples in the new buffer were also reanalysed after storage at 35℃ and 50℃. Results were expressed as percentage of the initial concentration, and the number of days that levels were maintained to at least 80% was calculated. Results Haemoglobin concentrations were maintained above 80% of their initial concentration with both freezer and refrigerator storage, regardless of buffer formulation or storage duration. Stability at room temperature was significantly better in the new buffer, with haemoglobin remaining above 80% for 20 days compared with six days in the original buffer. Storage at 35℃ or 50℃ in the new buffer maintained haemoglobin above 80% for eight and two days, respectively. Conclusion The new formulation buffer has enhanced haemoglobin stabilizing properties when samples are exposed to temperatures greater than 22℃.
Protein carbonylation: avoiding pitfalls in the 2,4-dinitrophenylhydrazine assay.
Luo, Shen; Wehr, Nancy B
2009-01-01
Protein carbonyl content is widely used as both a marker for oxidative stress and a measure of oxidative damage. Widely used methods for determination of protein carbonylation utilize the reaction of carbonyl groups with 2,4-dinitrophenylhydrazine (DNPH) to form protein-bound 2,4-dinitrophenylhydrazones. Hydrazones can be quantitated spectrophotometrically or, for greater sensitivity, detected immunochemically with anti-dinitrophenyl antibodies. Attention to methodology is important to avoid artifactual elevation in protein carbonyl measurements. We studied extracts of Escherichia coli to identify and eliminate such effects. Nucleic acid contamination caused serious artifactual increases in the protein carbonyl content determined by spectrophotometric techniques. Both in vitro synthesized DNA oligonucleotides and purified chromosomal DNA reacted strongly with 2,4-DNPH. Treatment of cell extracts with DNase+RNase or with streptomycin sulfate to precipitate nucleic acids dramatically reduced the apparent carbonyl, while exposure to proteinase K did not. The commercial kit for immunochemical detection of protein carbonylation (OxyBlot from Chemicon/Millipore) recommends a high concentration of thiol in the homogenizing buffer. We found this recommendation leads to an artifactual doubling of the protein carbonyl, perhaps due to a thiol-stimulated Fenton reaction. Avoiding oxidizing conditions, removal of nucleic acids, and prompt assay of samples can prevent artifactual effects on protein carbonyl measurements.
Combined Functional and Immunochemical Analysis of Normal and Abnormal Human Factor X
Fair, Daryl S.; Plow, Edward F.; Edgington, Thomas S.
1979-01-01
Human Factor X was isolated from Cohn fraction III and characterized by polyacrylamide gel electrophoresis, amino acid composition, and isoelectric focusing. Two molecular forms with biological activity were observed at isoelectric points of 4.8 and 5.0. Antisera generated to Factor X was monospecific and used to establish an equilibrium competitive inhibition radioimmunoassay. This assay was specific for human Factor X and did not cross-react with human prothrombin or bovine Factor X within the sensitivity range of 6-300 ng Factor X antigen/ml. The mean concentration of Factor X based on the antigen was 11.9 μg/ml, whereas concentration values based on coagulant activity was 7.8 μg/ml. This 30% difference in measurement appears to result from the presence of a subpopulation of Factor X molecules devoid of coagulant activity. The radioimmunoassay was used to qualitatively and quantitatively compare purified Factor X to plasmic Factor X obtained from normal, warfarintreated, acquired Factor X-deficient, and congenitaldeficient patients. In all but one case, the Factor X present in these plasmas was immunochemically identical to the purified Factor X and permitted precise quantitation of these abnormal Factor X molecules. Factor X procoagulant activity was analyzed relative to Factor X antigen and the specific activities were used to characterize normal and abnormal Factor X molecules. Reduced Factor X activity in plasmas from warfarin-treated and acquired Factor X-deficient patients was attributed to both decreases in Factor X antigen and decreased function of the Factor X molecules. Congenitally deficient patients, in general, showed a reduction in Factor X antigen in parallel with Factor X procoagulant activities resulting from comparable decreases in specific biological activity of the molecules. Images PMID:90058
Niedermaier, Tobias; Weigl, Korbinian; Hoffmeister, Michael; Brenner, Hermann
2017-01-01
Background Colorectal cancer (CRC) is a common but largely preventable cancer. Although fecal immunochemical tests (FITs) detect the majority of CRCs, they miss some of the cancers and most advanced adenomas (AAs). The potential of blood tests in complementing FITs for the detection of CRC or AA has not yet been systematically investigated. Methods We conducted a systematic review of performance of FIT combined with an additional blood test for CRC and AA detection versus FIT alone. PubMed and Web of Science were searched until June 9, 2017. Results Some markers substantially increased sensitivity for CRC when combined with FIT, albeit typically at a major loss of specificity. For AA, no relevant increase in sensitivity could be achieved. Conclusion Combining FIT and blood tests might be a promising approach to enhance sensitivity of CRC screening, but comprehensive evaluation of promising marker combinations in screening populations is needed. PMID:29435309
Miuţescu, Bogdan; Sporea, Ioan; Popescu, Alina; Bota, Simona; Iovănescu, Dana; Burlea, Amelia; Mos, Liana; Miuţescu, Eftimie
2013-01-01
The aim of this study is to evaluate the usefulness of the fecal immunochemical test (FIT) in colorectal cancer screening, detection of precancerous lesions and early colorectal cancer. The study evaluated asymptomatic patients with average risk (no personal or family antecedents of polyps or colorectal cancer), aged between 50 and 74 years. The presence of the occult haemorrhage was tested with the immunochemical faecal test Hem Check 1 (Veda Lab, France). The subjects were not requested to have any dietary or drug restrictions. Colonoscopy was recommended in all subjects that tested positive. In our study, we had a total of 1389 participants who met the inclusion criteria, with a mean age of 61.2 ± 12.8 years, 565 (40.7%) men and 824 (59.3%) women. FIT was positive in 87 individuals (6.3%). In 57/87 subjects (65.5%) with positive FIT, colonoscopy was performed, while the rest of the subjects refused or delayed the investigation. A number of 5 (8.8%) patients were not able to have a complete colonoscopy, due to neoplastic stenosis. The colonoscopies revealed in 10 cases (0.7%) cancer, in 29 cases (2.1%) advanced adenomas and in 15 cases (1.1%) non advanced adenomas from the total participants in the study. The colonoscopies performed revealed a greater percentage of advanced adenomas in the left colon compared to the right colon, 74.1% vs. 28.6% (p<0.001). In our study, FIT had a positivity rate of 6.3%. The detection rate for advanced neoplasia was 2.8% (0.7% for cancer, 2.1% for advanced adenomas) in our study group. Adherence to colonoscopy for FIT-positive subjects was 65.5%.
Unexpected extent of immunochemical cross-reactions between rabbit and human serum proteins
Johnson, P. K.; Yoder, J. M.
1970-01-01
Precipitin experiments indicated an unexpected extent of immunochemical cross-reactions between rabbit and human serum proteins. Commerical goat or horse antisera to human or rabbit serum were used. Two of the proteins involved in the cross-reactions were lipoproteins. Imagesp294-ap296-a PMID:4991121
Nielsen, R G; Wilson, G S
1987-12-25
Low-level adsorption on the stationary phase has been studied using immunochemical reagents. An immunoaffinity column has been evaluated using affinity-purified radioisotope-labeled monoclonal antibodies. Recovery experiments including continuous immunosorbent monitoring have been performed. Proper characterization of an immunoaffinity separation can result in the recovery of immunologically active material in high yield.
Vitale, Elsa
2012-04-01
Sexual assault was a ubiquitous and serious problem in our society. The world's care centers and forensic associations, which were at the forefront of scientific research in sexual assaults, discussed the role of the Forensic Nursing in their early diagnosis and their prevention, but little has been written in literature regarding their appropriate management. This article focuses on the immunochemical laboratory investigation in diagnosis and prevention of its adverse effects in sexual assaults and the role of the Forensic Nursing played in this task. After a careful reading of all the material received from many of the care centers and the associations contacted, a Forensic Nursing Examination Program, with specific immunochemical address, is identified.
Hotta, Kinichi; Matsuda, Takahisa; Kakugawa, Yasuo; Ikematsu, Hiroaki; Kobayashi, Nozomu; Kushima, Ryoji; Hozawa, Atsushi; Nakajima, Takeshi; Sakamoto, Taku; Mori, Mika; Fujii, Takahiro; Saito, Yutaka
2017-02-13
Colorectal cancer screening program using fecal immunochemical test had been conducted on an isolated island named Nii-jima. However, the participation rate of the program had been approximately 12%, which was lower than average level of Japan. This study aimed to evaluate the participation rate, safety and efficacy of a colorectal cancer screening program using colonoscopy on the island. Educational campaigns were actively conducted every month using information bulletins and special propaganda pamphlets. The primary recommended modality was colonoscopy, followed by fecal immunochemical test. The participants of this program were 1671 individuals aged 40–79 years (men, 819; women, 852). A total of 789 (47.2%) individuals provided consent for this screening program, and 89.2% (704/789) of participants chose colonoscopy as the primary screening procedure. The completion rate of total colonoscopy was 99.7%, and there was no complication during this program. Detection rates of invasive cancer, intramucosal cancer, advanced neoplasia and any adenoma were 0.9% (n = 6), 2.4% (n = 17), 11.8% (n = 83) and 50.0% (n = 352), respectively. The adenoma detection rate and incidence of advanced neoplasia were significantly higher in men than in women in all age groups. The colorectal cancer screening program using colonoscopy that was conducted on an island achieved considerably higher participation rate than the conventional screening program using fecal immunochemical test. Completion rate and safety of screening colonoscopy were excellent during this program.
Comparison between immunofluorescence and immunomagnetic techniques of cytometry
NASA Astrophysics Data System (ADS)
Tchikov, V.; Schütze, S.; Krönke, M.
1999-04-01
Magnetophoresis and fluorescence activated cell sorting were used for evaluation of immunochemical properties of magnetic particles and fluorescent probes. The HLA-Bw6 antigen on surfaces of REH cells was detected with a primary monoclonal antibody and a secondary antibody coupled with fluorescent molecules or magnetic particles. Magnetophoresis can find applications in biology and medicine for measuring percentages of cell subpopulations.
Meusy, J J; Martin, G; Soyez, D; van Deijnen, J E; Gallo, J M
1987-09-01
Immunochemical investigations, using dot immunobinding assay (DIA) and enzyme-linked immunosorbent assay (ELISA), and immunocytochemical studies reveal the following new information about crustacean vitellogenesis-inhibiting hormone (VIH): (1) The structure of VIH is sufficiently different from that of the other sinus gland neuropeptides to allow a selective recognition of VIH by polyclonal antibodies. (2) From immunochemical criteria, VIH does not seem strictly species specific. The antisera raised against VIH of Homarus americanus cross-react with sinus gland extracts of Palaemonetes varians, Palaemon serratus, Macrobrachium rosenbergii, Carcinus maenas, and Porcellio dilatatus. (3) In the sinus gland of H. americanus, VIH immunoreactivity is localized mainly in electron-dense granules of medium size (110-185 nm in diameter) while, in P. dilatatus, the labeling is mostly on the largest granules (200-270 nm in diameter).
Catomeris, Peter; Baxter, Nancy N; Boss, Sheila C; Paszat, Lawrence F; Rabeneck, Linda; Randell, Edward; Serenity, Mardie L; Sutradhar, Rinku; Tinmouth, Jill
2018-01-01
- Although promising for colorectal cancer screening, hemoglobin (Hb) stability remains a concern with fecal immunochemical tests. This study implemented a novel, standardized method to compare Hb stability across various fecal immunochemical tests. The method can be used to inform decisions when selecting a kit for use in colorectal cancer screening. In so doing, this work addressed a critical need for standardization in this field. - To compare the stability of Hb across 5 different immunochemical kits and one guaiac kit. - The stability of Hb was analyzed in collection devices inoculated with Hb-spiked feces and (1) stored at various temperatures (frozen, refrigerated, ambient, and elevated) for more than 60 days; (2) after undergoing 3 controlled, freeze-thaw cycles; and (3) after being transported by courier or postal services in uncontrolled temperature conditions from 3 locations in Ontario, Canada, to a central testing center. - The stability of Hb varied with time and temperature and by kit. Lower Hb recoveries occurred with increasing temperature and increasing time from sample collection to testing. Refrigeration provided the best stability, although results varied across kits (eg, from 4.2 days to >60 days before a prespecified threshold [<70% probability of the test results remaining positive] was reached). Freeze-thaw stability varied across kits and cycles (Hb recoveries: NS Plus [Alfresa Pharma, Chuo-ku, Osaka, Japan], 91.7% to 95.4%; OC Diana [Eiken Chemical, Taito-ku, Tokyo, Japan], 57.6% to 74.9%). Agreement regarding Hb levels before and after transportation varied across kits (from 57% to 100%). - Important differences in Hb stability were found across the included fecal immunochemical tests. These findings should inform practice-based and population-based colorectal cancer screening.
Salvador, J-Pablo; Vila-Roca, Ester; Monfort, Núria; Ventura, Rosa; Marco, M-Pilar
2018-04-22
Antiestrogenic compounds such as tamoxifen, toremifen and chlomifen are used illegally by athletes to minimize physical impacts such as gynecomastia resulting from the secondary effects of anabolic androgenic steroids, used to increase athletic efficiency unlawfully. The use of these compounds is banned by the World Anti-Doping Agency (WADA) and controls are made through analytical methodologies such as HPLC-MS/MS, which do not fulfil the sample throughput requirements. Moreover, compounds such as tamoxifen are also used to treat hormone receptor-positive breast cancer (ER + ).Therapeutic drug monitoring (TDM) of tamoxifen may also be clinically useful for guiding treatment decisions. An accurate determination of these drugs requires a solid phase extraction of patient serum followed by HPLC-MS/MS. In the context of an unmet need of high-throughput screening (HTS) and quantitative methods for antiestrogenic substances we have approached the development of antibodies and an immunochemical assay for the determination of these antiestrogenic compounds. The strategy applied has taken into consideration that these drugs are metabolized and excreted in urine as the corresponding 4-hydroxylated compounds. A microplate-based ELISA procedure has been developed for the analysis of these metabolites in urine with a LOD of 0.15, 0.16 and 0.63 μg/L for 4OH-tamoxifen, 4OH-toremifen and 4OH-clomifen, respectively, much lower than the MRPL established by WADA (20 μg/L). Copyright © 2018 Elsevier B.V. All rights reserved.
Recent advances in detection of AGEs: Immunochemical, bioanalytical and biochemical approaches.
Ashraf, Jalaluddin Mohd; Ahmad, Saheem; Choi, Inho; Ahmad, Nashrah; Farhan, Mohd; Tatyana, Godovikova; Shahab, Uzma
2015-12-01
Advanced glycation end products (AGEs) are a cohort of heterogeneous compounds that are formed after the nonenzymatic glycation of proteins, lipids and nucleic acids. Accumulation of AGEs in the body is implicated in various pathophysiological conditions like diabetes, cardiovascular diseases and atherosclerosis. Numerous studies have reported the connecting link between AGEs and the various complications associated with diseases. Hence, detection and measurement of AGEs becomes centrally important to understand and manage the menace created by AGEs inside the body. In recent years, an increasing number of immunotechniques as well as bioanalytical techniques have been developed to efficiently measure the levels of AGEs, but most of them are still far away from being clinically consistent, as relative disparity and ambiguity masks their standardization. This article is designed to critically review the recent advances and the emerging techniques for detection of AGEs. It is an attempt to summarize the major techniques that exist currently for the detection of AGEs both qualitatively and quantitatively. This review primarily focuses on the detection and quantification of AGEs which are formed in vivo. Immunochemical approach though costly but most effective and accurate method to measure the level of AGEs. Literature review suggests that detection of autoantibody targeting AGEs is a promising way that can be utilized for detection of AGEs. Future research efforts should be dedicated to develop this method in order to push forward the clinical applications of detection of AGEs. © 2015 International Union of Biochemistry and Molecular Biology.
Schwartz, Peter H; Perkins, Susan M; Schmidt, Karen K; Muriello, Paul F; Althouse, Sandra; Rawl, Susan M
2017-08-01
Guidelines recommend that patient decision aids should provide quantitative information about probabilities of potential outcomes, but the impact of this information is unknown. Behavioral economics suggests that patients confused by quantitative information could benefit from a "nudge" towards one option. We conducted a pilot randomized trial to estimate the effect sizes of presenting quantitative information and a nudge. Primary care patients (n = 213) eligible for colorectal cancer screening viewed basic screening information and were randomized to view (a) quantitative information (quantitative module), (b) a nudge towards stool testing with the fecal immunochemical test (FIT) (nudge module), (c) neither a nor b, or (d) both a and b. Outcome measures were perceived colorectal cancer risk, screening intent, preferred test, and decision conflict, measured before and after viewing the decision aid, and screening behavior at 6 months. Patients viewing the quantitative module were more likely to be screened than those who did not ( P = 0.012). Patients viewing the nudge module had a greater increase in perceived colorectal cancer risk than those who did not ( P = 0.041). Those viewing the quantitative module had a smaller increase in perceived risk than those who did not ( P = 0.046), and the effect was moderated by numeracy. Among patients with high numeracy who did not view the nudge module, those who viewed the quantitative module had a greater increase in intent to undergo FIT ( P = 0.028) than did those who did not. The limitations of this study were the limited sample size and single healthcare system. Adding quantitative information to a decision aid increased uptake of colorectal cancer screening, while adding a nudge to undergo FIT did not increase uptake. Further research on quantitative information in decision aids is warranted.
van der Put, Robert M F; de Haan, Alex; van den IJssel, Jan G M; Hamidi, Ahd; Beurret, Michel
2015-11-27
Due to the rapidly increasing introduction of Haemophilus influenzae type b (Hib) and other conjugate vaccines worldwide during the last decade, reliable and robust analytical methods are needed for the quantitative monitoring of intermediate samples generated during fermentation (upstream processing, USP) and purification (downstream processing, DSP) of polysaccharide vaccine components. This study describes the quantitative characterization of in-process control (IPC) samples generated during the fermentation and purification of the capsular polysaccharide (CPS), polyribosyl-ribitol-phosphate (PRP), derived from Hib. Reliable quantitative methods are necessary for all stages of production; otherwise accurate process monitoring and validation is not possible. Prior to the availability of high performance anion exchange chromatography methods, this polysaccharide was predominantly quantified either with immunochemical methods, or with the colorimetric orcinol method, which shows interference from fermentation medium components and reagents used during purification. Next to an improved high performance anion exchange chromatography-pulsed amperometric detection (HPAEC-PAD) method, using a modified gradient elution, both the orcinol assay and high performance size exclusion chromatography (HPSEC) analyses were evaluated. For DSP samples, it was found that the correlation between the results obtained by HPAEC-PAD specific quantification of the PRP monomeric repeat unit released by alkaline hydrolysis, and those from the orcinol method was high (R(2)=0.8762), and that it was lower between HPAEC-PAD and HPSEC results. Additionally, HPSEC analysis of USP samples yielded surprisingly comparable results to those obtained by HPAEC-PAD. In the early part of the fermentation, medium components interfered with the different types of analysis, but quantitative HPSEC data could still be obtained, although lacking the specificity of the HPAEC-PAD method. Thus, the HPAEC-PAD method has the advantage of giving a specific response compared to the orcinol assay and HPSEC, and does not show interference from various components that can be present in intermediate and purified PRP samples. Copyright © 2014 Elsevier Ltd. All rights reserved.
Immunogold Staining of Ultrathin Thawed Cryosections for Transmission Electron Microscopy (TEM).
Skepper, Jeremy N; Powell, Janet M
2008-06-01
INTRODUCTIONA pre-embedding method of immunochemical staining is used if antigens are damaged by resin embedding, or if the best preservation of membranes is required. Applying immunogold reagents to sections of lightly fixed tissue, free of embedding medium, can be a very sensitive method of immunochemical staining. Cells or tissues are fixed as strongly as possible and then treated with a cryoprotectant, which is usually a mixture of sucrose and polyvinylpyrrolidone (PVP). They are frozen onto pins in liquid nitrogen and sectioned at approximately -100°C. The frozen sections are thaw-mounted on to Formvar/nickel film grids and the cryoprotectant is removed by floating the grids on drops of phosphate-buffered saline (PBS). The immunogold staining is performed on the unembedded sections, which are subsequently contrast counterstained and infiltrated with a mixture of methylcellulose and uranyl acetate. In this protocol, samples are sectioned at low temperature, thaw-mounted onto film grids, immunochemically stained, contrast counterstained, and embedded/encapsulated in situ on the grid before viewing by transmission electron microscopy (TEM).
Fraser, Callum G.; Halloran, Stephen P.; Young, Graeme P.
2014-01-01
Fecal immunochemical tests for hemoglobin (FIT) are changing the manner in which colorectal cancer (CRC) is screened. Although these tests are being performed worldwide, why is this test different from its predecessors? What evidence supports its adoption? How can this evidence best be used? This review addresses these questions and provides an understanding of FIT theory and practices to expedite international efforts to implement the use of FIT in CRC screening. PMID:24672652
Screening for colon cancer: A test for occult blood.
Khakimov, N; Khasanova, G; Ershova, K; Gibadullina, L; Vetkina, T; Lobisheva, G; Chumakova, A
2015-01-01
The relevance of the problem of colorectal cancer (CRC) is evident because of extremely high morbidity and mortality rates, associated with this disease. CRC is mostly diagnosed only at very advanced stages. The reduction of mortality can be achieved by the popularization of screening-methods for early identification of CRC and adenomatous polyps of the colon, which are proved to be precancerous condition. Fecal occult blood test is a well-known method of screening for CRC. The advantages of this method when compared, for example, with colonoscopy are its simplicity and cost-effectiveness.Two techniques are usually used for detection of occult blood in the stool: Hemoccult (Guaiac) test and immunochemical test for hemoglobin. There is no consensus among researchers regarding the validity of these tests for the diagnosis of colorectal cancer. For example, J.S. Mandel (1996) notes 60% sensitivity of Guaiac-test for the detection of the early forms of colorectal cancer, while O.I. Kit (2014) suggets that it is not higher than 30%. There are also various opinions about specificity of these two tests. To review the literature on the validity of the fecal occult blood tests for the diagnosis of CRC. We looked for articles (electronic versions) available for free in the full-text versions, published from June 1, 1990 to December 31, 2014 in Russian or English. The following databases were used for search: E-LIBRARY; Cochrane; MEDLINE; EMBASE; Google search. Only original research papers were analyzed. Literature reviews or systematic reviews were not taken for analyses. 1) use of Guaiac and/or immunochemical fecal occult blood test as screening-tests for the detection of colorectal cancer and/or colon polyps (1 cm or more in diameter) in people older than 45 years; 2) comparing of results with the results of colonoscopy (colonoscopy is counted by majority of the authors as a "gold standard" for the diagnosis of CRC and adenomatous polyps). Initial keyword search returned 803 000 results, of which 449 sources were selected. After reading the abstracts, 29 articles that met inclusion criteria were kept. 10 other articles were excluded after that because they did not contain enough data for extraction or did not contain a control group. At the final step 19 articles were used for meta-analysis.Forest plot and Rock curve, which were developed with inclusion of the data from all studies, showed heterogeneity of the data. Additional analyzes were performed in subgroups with different diagnoses and various tests.The sensitivity of the Guaiac test for the diagnosis of colorectal cancer varied from 0.13 to 1.00, and specificity - from 0.69 to 0.99. The sensitivity of the immunochemical test for the diagnosis of CRC ranged from 0.42 to 0.94 with specificity ranging from 0.40 to 1.00.The sensitivity of the Guaiac test for the diagnosis of the colon polyps was between 0.05 and 0.69, and its specificity - from 0.67 to 0.98. The sensitivity of the immunochemical test for the diagnosis of polyps was from 0.24 to 0.75, and its specificity - from 0.40 to 0.97.Bivariate analysis of the validity of Guaiac test and immunochemical method for the diagnosis of colorectal cancer showed better results for the immunochemical test compared to Guaiac test. The tests showed very similar results when used for the diagnosis of polyposis. Bivariate analysis, comparing the validity of tests for the diagnosis of colorectal cancer versus polyposis demonstrated better results for CRC.Multivariate analysis of the validity of the Guaiac and immunochemical tests for the diagnosis of colorectal cancer and polyps also showed better results for detection of colorectal cancer compared with the polyps for both tests. At the same time the highest validity for the diagnosis of CRC was demonstrated for immunochemical analysis. 1. The sensitivity of the Guaiac test for occult blood in stool is lower than its specificity.2. Broad dispersion of the validity characteristics of the fecal occult blood tests was observed.3. The validity of tests for occult blood was higher when they were used for detection of colorectal cancer than of colon polyposis.4. The highest validity rate has been demonstrated for the immunochemical test when it was used for colon cancer screening.
Blintsov, A N; Gussakovskaya, M A
2004-10-01
An original modification of the standard ELISA procedure for differential determination of different forms of abscisic acid (ABA) is proposed. It is shown that endogenous forms of ABA may be quantitatively determined in plant tissues subjected to minimal treatment, without purification of the hormones and their chemical modification. The modification has been approved when analyzing changes in the content of different ABA forms in plant tissues differing in physiological activity. Quantitative differential determination of changes in the content of different ABA forms has been performed in ovaries of Triticum aestivum L. and Taraxacum officinale Web. in the period of activity of the ovule (from the moment of its activation to the beginning of division). It is shown that, despite the different types of reproduction in the species studied (amphimixis and apomixis), the time course of changes in the content of different forms of ABA in ovaries is similar, which is suggestive of a correlation between the activity of endogenous hormonal system and chronology of main events (e.g., the beginning of endospermogenesis) of the reproductive cycle.
Light microscopic study of periapical lesions associated with asymptomatic apical periodontitis.
Kabak, S L; Kabak, Y S; Anischenko, S L
2005-04-01
The purpose of the study has been to evaluate the degree of chronic inflammation in tissues surrounding the apex of the tooth root in patients with apical periodontitis in the remission phase. The material included 37 apical granulomas and radicular cysts obtained as a result of apiectomy, and 20 teeth which were removed together with the focus of the periapical inflammation. Routine histological techniques, as well as the immunofluorescent and immuno-chemical methods were used to examine the material. Despite the absence of clinical symptoms in 23 of 57 cases, the morphological signs of chronic inflammation were observed in the apical area of the tooth root. Morphological signs of viral invasion of epithelial and stromal cells in the radicular cyst wall were revealed in six cases. The presence of the virus of Herpes simplex I in epithelial cells (five cases) and adenoviral invasion (one case) was confirmed by immuno-fluorescent and immuno-chemical methods. Histological examination often reveals morphological signs of an active inflammatory process in the periapical tissues of patients treated during clinical remission. In our opinion, the presence of viruses in the epithelial cells of the radicular cyst may contribute to the persistence of the active stage of the inflammatory process.
Which Fecal Immunochemical Test Should I Choose?
Daly, Jeanette M.; Xu, Yinghui; Levy, Barcey T.
2017-01-01
Objectives: To summarize the fecal immunochemical tests (FITs) available in the United States, the 2014 pathology proficiency testing (PT) program FIT results, and the literature related to the test characteristics of FITs available in the United States to detect advanced adenomatous polyps (AAP) and/or colorectal cancer (CRC). Methods: Detailed review of the Food and Drug Administration’s Clinical Laboratory Improvement Amendments (CLIA) database of fecal occult blood tests, the 2014 FIT PT program results, and the literature related to FIT accuracy. Results: A search of the CLIA database identified 65 FITs, with 26 FITs available for purchase in the United States. Thirteen of these FITs were evaluated on a regular basis by PT programs, with an overall sensitivity of 99.1% and specificity of 99.2% for samples spiked with hemoglobin. Automated FITs had better sensitivity and specificity than CLIA-waived FITs for detection of AAP and CRC in human studies using colonoscopy as the gold standard. Conclusion: Although many FITs are available in the United States, few have been tested in proficiency testing programs. Even fewer have data in humans on sensitivity and specificity for AAP or CRC. Our review indicates that automated FITs have the best test characteristics for AAP and CRC. PMID:28447866
Immunochemical Detection Methods for Gluten in Food Products: Where Do We Go from Here?
Slot, I D Bruins; van der Fels-Klerx, H J; Bremer, M G E G; Hamer, R J
2016-11-17
Accurate and reliable quantification methods for gluten in food are necessary to ensure proper product labeling and thus safeguard the gluten sensitive consumer against exposure. Immunochemical detection is the method of choice, as it is sensitive, rapid and relatively easy to use. Although a wide range of detection kits are commercially available, there are still many difficulties in gluten detection that have not yet been overcome. This review gives an overview of the currently commercially available immunochemical detection methods, and discusses the problems that still exist in gluten detection in food. The largest problems are encountered in the extraction of gluten from food matrices, the choice of epitopes targeted by the detection method, and the use of a standardized reference material. By comparing the available techniques with the unmet needs in gluten detection, the possible benefit of a new multiplex immunoassay is investigated. This detection method would allow for the detection and quantification of multiple harmful gluten peptides at once and would, therefore, be a logical advancement in gluten detection in food.
Khuda, Sefat; Slate, Andrew; Pereira, Marion; Al-Taher, Fadwa; Jackson, Lauren; Diaz-Amigo, Carmen; Bigley, Elmer C; Whitaker, Thomas; Williams, Kristina M
2012-05-02
Among the major food allergies, peanut, egg, and milk are the most common. The immunochemical detection of food allergens depends on various factors, such as the food matrix and processing method, which can affect allergen conformation and extractability. This study aimed to (1) develop matrix-specific incurred reference materials for allergen testing, (2) determine whether multiple allergens in the same model food can be simultaneously detected, and (3) establish the effect of processing on reference material stability and allergen detection. Defatted peanut flour, whole egg powder, and spray-dried milk were added to cookie dough at seven incurred levels before baking. Allergens were measured using five commercial enzyme-linked immunosorbent assay (ELISA) kits. All kits showed decreased recovery of all allergens after baking. Analytical coefficients of variation for most kits increased with baking time, but decreased with incurred allergen level. Thus, food processing negatively affects the recovery and variability of peanut, egg, and milk detection in a sugar cookie matrix when using immunochemical methods.
NASA Technical Reports Server (NTRS)
Riley, Danny A.; Bain, James L. W.; Haas, Arthur L.; Ellis, Stanley
1988-01-01
Solid-phase immunochemical methods were employed to probe the dynamics of ubiquitin pools within selected rat skeletal muscles. The total ubiquitin content of red muscles was greater than that of white muscles, even though the fractional conjugation was similar for both types of muscles. The specificity for conjugated ubiquitin in solid-phase applications, previously demonstrated for an affinity-purified antibody against SDS-denatured ubiquitin, was retained when used as a probe for ubiquitin-protein adducts in tissue sections. Immunohistochemical localization revealed that differences in ubiquitin pools derived from the relative content of red (oxidative) vs white (glycolytic) fibers, with the former exhibiting a higher content of ubiquitin conjugates. Subsequent immunogold labeling demonstrated statistically significant enhanced localization of ubiquitin conjugates to the Z-lines in both red and white muscle fiber types.
Colorectal cancer in a second round after a negative faecal immunochemical test.
Bujanda, Luis; Sarasqueta, Cristina; Castells, Antoni; Pellisé, María; Cubiella, Joaquín; Gil, Inés; Cosme, Angel; Arana-Arri, Eunate; Mar, Izaskun; Idigoras, Isabel; Portillo, Isabel
2015-07-01
The faecal immunochemical test is one of the tests recommended by scientific societies for colorectal cancer (CRC) screening in average-risk populations. Our aim was to evaluate the characteristics of CRC detected in a second round of screening after negative results in a first round. We studied patients in whom CRC was detected in a screening programme. This programme included asymptomatic individuals between 50 and 69 years old and offered tests every 2 years. A total of 363,792 individuals were invited to participate in the first round of faecal immunochemical test screening and 100,135 individuals in the second round after a first negative result. The screening strategy consisted of faecal testing of a single sample using an automated semiquantitative kit, with a cut-off of 20 μg haemoglobin (Hb)/g faeces. The rate of positive results was 6.9% (16,467/238,647) in the first round and 4.8% (3359/69,193) in the second round (P < 0.0005). Overall, 860 (0.36%) cases of CRC were detected in the first round and 100 (0.14%) in the second round (P < 0.005). The location of the cancer was proximal in 12.5 and 24% of cases detected in the first and second rounds, respectively (P = 0.008). Hb concentrations were higher in the first round (211 vs. 109 μg Hb/g faeces in the second round; P = 0.002). Multivariate analysis confirmed that, in the second round, CRC diagnosed was more often proximal (hazard ratio vs. first round, 2.4; 95% confidence interval, 1.3-4.4; P = 0.003) and the concentration of Hb/g faeces was lower (hazard ratio vs. first round, 2.1; 95% confidence interval, 1.3-3.5; P = 0.003). The CRC detection rate is lower in the second round of screening. Further, in the second round, CRC detected is more often in a proximal location and Hb concentrations are lower.
Shin, Hye Young; Suh, Mina; Baik, Hyung Won; Choi, Kui Son; Park, Boyoung; Jun, Jae Kwan; Hwang, Sang-Hyun; Kim, Byung Chang; Lee, Chan Wha; Oh, Jae Hwan; Lee, You Kyoung; Han, Dong Soo; Lee, Do-Hoon
2016-11-15
We are in the process of conducting a randomized trial to determine whether compliance with the fecal immunochemical test (FIT) for colorectal cancer screening differs according to the stool-collection method. This study was an interim analysis of the performance of two stool-collection devices (sampling bottle vs conventional container). In total, 1,701 individuals (age range, 50 to 74 years) were randomized into the sampling bottle group (intervention arm) or the conventional container group (control arm). In both groups, we evaluated the FIT positivity rate, the positive predictive value for advanced neoplasia, and the detection rate for advanced neoplasia. The FIT positivity rates were 4.1% for the sampling bottles and 2.0% for the conventional containers; these values were significantly different. The positive predictive values for advanced neoplasia in the sampling bottles and conventional containers were 11.1% (95% confidence interval [CI], -3.4 to 25.6) and 12.0% (95% CI, -0.7 to 24.7), respectively. The detection rates for advanced neoplasia in the sampling bottles and conventional containers were 4.5 per 1,000 persons (95% CI, 2.0 to 11.0) and 2.4 per 1,000 persons (95% CI, 0.0 to 5.0), respectively. The impact of these findings on FIT screening performance was unclear in this interim analysis. This impact should therefore be evaluated in the final analysis following the final enrollment period.
Liles, Elizabeth G; Perrin, Nancy; Rosales, Ana G; Smith, David H; Feldstein, Adrianne C; Mosen, David M; Levin, Theodore R
2018-05-02
The fecal immunochemical test (FIT) is easier to use and more sensitive than the guaiac fecal occult blood test, but it is unclear how to optimize FIT performance. We compared the sensitivity and specificity for detecting advanced colorectal neoplasia between single-sample (1-FIT) and two-sample (2-FIT) FIT protocols at a range of hemoglobin concentration cutoffs for a positive test. We recruited 2,761 average-risk men and women ages 49-75 referred for colonoscopy within a large nonprofit, group-model health maintenance organization (HMO), and asked them to complete two separate single-sample FITs. We generated receiver-operating characteristic (ROC) curves to compare sensitivity and specificity estimates for 1-FIT and 2-FIT protocols among those who completed both FIT kits and colonoscopy. We similarly compared sensitivity and specificity between hemoglobin concentration cutoffs for a single-sample FIT. Differences in sensitivity and specificity between the 1-FIT and 2-FIT protocols were not statistically significant at any of the pre-specified hemoglobin concentration cutoffs (10, 15, 20, 25, and 30 μg/g). There was a significant difference in test performance of the one-sample FIT between 50 ng/ml (10 μg/g) and each of the higher pre-specified cutoffs. Disease prevalence was low. A two-sample FIT is not superior to a one-sample FIT in detection of advanced adenomas; the one-sample FIT at a hemoglobin concentration cutoff of 50 ng/ml (10 μg/g) is significantly more sensitive for advanced adenomas than at higher cutoffs. These findings apply to a population of younger, average-risk patients in a U.S. integrated care system with high rates of prior screening.
Binefa, Gemma; Garcia, Montse; Milà, Núria; Fernández, Esteve; Rodríguez-Moranta, Francisco; Gonzalo, Núria; Benito, Llúcia; Clopés, Ana; Guardiola, Jordi; Moreno, Víctor
2016-01-20
Effective quality assurance is essential in any screening programme. This article provides a unique insight into key quality indicators of five rounds of the first population-based colorectal cancer screening programme implemented in Spain (2000-2012), providing the results according to the type of screening (prevalent or first screen and incident or subsequent screen) and test (guaiac or immunochemical). The total crude participation rate increased from 17.2% (11,011) in the first round to 35.9% (22,988) in the last one. Rescreening rate was very high (88.6% in the fifth round). Positivity rate was superior with the faecal immunochemical test (6.2%) than with the guaiac-based test (0.7%) (p < 0.0001) and detection rates were also better with the immunochemical test. The most significant rise in detection rate was observed for high risk adenoma in men (45.5 per 1,000 screened). Most cancers were diagnosed at an early stage (61.4%) and there was a statistically significant difference between those detected in first or subsequent screening (52.6% and 70.0% respectively; p = 0.024). The availability of these results substantially improves data comparisons and the exchange of experience between screening programmes.
Eremkin, A V; Elagin, G D; Petchenkin, D V; Fomenkov, O O; Bogatcheva, N V; Kitmanov, A A; Kuklina, G V; Tikhvinskaya, O V
2016-03-01
The immune enzyme and immunochromatographic test-systems for detecting tularemia agent were developed on the basis of selected set of monoclonal antibodies having immunochemical activity to antigens Francisella tularensis. The evaluation of sensitivity and specificity of developed test-systems demonstrated that samples provided detection of strains of F. tularensis in concentration from 5.0 x 105 mkxcm-3 to 1.0 x 106 mkxcm-3 and gave no false positive results in analysis of heterologous microorganisms in concentration of 1.0 x 108 mkxcm-3.
Physicochemical and immunochemical assays for monitoring consistent production of tetanus toxoid.
Metz, Bernard; Tilstra, Wichard; van der Put, Robert; Spruit, Nanda; van den Ijssel, Jan; Robert, Jolanda; Hendriksen, Coenraad; Kersten, Gideon
2013-07-01
The detoxification of tetanus toxin by formaldehyde is a crucial step in the production of tetanus toxoid. The inactivation results in chemically modified proteins and it determines largely the ultimate efficacy and safety of the vaccine. Currently, the quality of tetanus toxoid lots is evaluated in potency and safety tests performed in animals. As a possible alternative, this article describes a panel of in vitro methods, which provides detailed information about the quality of tetanus toxoid. Ten experimental lots of tetanus toxoid were prepared using increasing concentrations of formaldehyde and glycine to obtain tetanus toxoids having differences in antigenicity, immunogenicity, residual toxicity and protein structure. The structural properties of each individual toxoid were determined using immunochemical and physicochemical methods, including biosensor analysis, ELISA, circular dichroism, TNBS assay, differential scanning calorimetry, fluorescence and SDS-PAGE. The quality of a tetanus toxoid lot can be assessed by these set of analytical techniques. Based on antigenicity, immunogenicity and residual toxicity data, criteria are formulated that tetanus toxoids lot have to meet in order to have a high quality. The in vitro methods are a valuable selection of techniques for monitoring consistency of production of tetanus toxoid, especially for the detoxification process of tetanus toxin. Copyright © 2013 The International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.
Adrian, Javier; Gratacós-Cubarsí, Marta; Sánchez-Baeza, Francisco; Garcia Regueiro, Jose-Antonio; Castellari, Massimo; Marco, M-Pilar
2009-10-01
The use of hair to trace use of unauthorized substances, therapeutic agents, or their misuse is becoming very attractive since residues can be detected for a long time after treatment. For this purpose, an indirect enzyme-linked immunosorbent assay (ELISA) has been evaluated for its capability to trace sulfonamide antibiotic treatment by analyzing cattle and pig hair samples. Pigmented and nonpigmented hair samples from control and sulfamethazine (SMZ)-treated pigs and calves were collected, extracted under different alkaline conditions, and analyzed by ELISA after just diluting the extracts with the assay buffer. Data analysis following the European recommendations for screening methods demonstrates that the ELISA can detect SMZ in hair samples with a limit of detection (90% of the zero dose (IC(90))) between 30 and 75 ng g(-1). The same samples have been analyzed by HPLC after a dual solid-phase extraction. The ELISA results matched very well those obtained by the chromatographic method, demonstrating that the immunochemical method can be used as a screening tool to trace animal treatments. Between the benefits of this method are the possibility to directly analyze hair extracts with sufficient detectability and its high-throughput capability. Preliminary validation data are reported using an experimental approach inspired on the Commission Decision 2002/657/EC criteria for screening methods.
Comparative Evaluation of Preliminary Screening Methods for Colorectal Cancer in a Mass Program.
Ye, Ding; Huang, Qiuchi; Li, Qilong; Jiang, Xiyi; Mamat, Mayila; Tang, Mengling; Wang, Jianbing; Chen, Kun
2017-09-01
The fecal immunochemical test (FIT) has been widely used in preliminary screening for colorectal cancer (CRC). The high-risk factor questionnaire (HRFQ) and quantitative risk-assessment method (QRAM) are recommended for estimating the risk of CRC qualitatively and quantitatively in China. We aimed to prospectively compare the diagnostic values of CRC preliminary screening methods to identify which method is preferable as a screening strategy. Individuals aged 40-74 years old were enrolled in a mass CRC screening program from January 1, 2007 to December 31, 2014, in Jiashan County, Zhejiang Province, China. FIT of two stool specimens at 1-week intervals was performed by laboratory personnel and face-to-face interviews were conducted by trained investigators. Screening data in the program were linked to a CRC surveillance and registry system, and CRC cases reported in the system were regarded as true patients. A total of 96,043 subjects were included. The sensitivity and specificity of FIT for detecting CRC cases were 75.49% (95% CI 69.84-80.39) and 90.36% (95% CI 90.17-90.54), respectively. QRAM was more sensitive (p < 0.001) and less specific (p < 0.001) than HRFQ. The sensitivity and specificity of FIT along with HRFQ were 86.56% (95% CI 81.81-90.22) and 81.37% (95% CI 81.12-81.62), and those of FIT along with QRAM were 88.93% (95% CI 84.47-92.23) and 73.95% (95% CI 73.67-74.23). Our findings suggest that CRC preliminary screening with FIT and QRAM in parallel has high sensitivity and satisfactory specificity, and is a useful strategy in mass screening programs.
Screening for colon cancer; Colonoscopy - screening; Sigmoidoscopy - screening; Virtual colonoscopy - screening; Fecal immunochemical test; Stool DNA test; sDNA test; Colorectal cancer - screening; Rectal ...
Proteins from disassembled microtubules characterized by oligospecific antisera.
Meier, E; Jorgensen, O S
1977-10-26
The immunochemical properties of in vitro reassembled microtubules were investigated by immunoelectrophoretic techniques. The tubulin dimer gave no measurable immunochemical response, but the tubulin oligomer, the tau-factor and an antigen of about 135 000 daltons all gave precipitating antibodies. Those four proteins were investigated in reassembled microtubules, in DEAE-cellulose purified tubulin, and after molecular sieve chromatography of disassembled and NaCl-dissociated microtubules. Reconstitution of tubulin oligomer from tubulin dimer and tau-factor was also performed. The presence of a unique antigenic structure on tubulin oligomer which was not found in the dissociated components and the role of this aggregate as a nucleation center or intermediate in the assembly of microtubules is discussed.
Aebig, J A; Jordan, R L; Lawson, R H; Hsu, H T
1987-01-01
A monoclonal antibody reacting with prunus necrotic ringspot ilarvirus was tested in immunochemical studies, neutralization of infectivity assays, and by immuno-electron microscopy. The antibody was able to detect the 27,000 Mr coat protein of prunus necrotic ringspot ilarvirus in western blots and also detected all polypeptide fragments generated after incubation of whole virus with proteolytic enzymes. In neutralization of infectivity studies, the antibody blocked virus infectivity, although it did not precipitate the antigen in agar gel Ouchterlony double diffusion tests. Immuno-electron microscopy confirmed that the antibody coats virions but does not cause clumping. The antibody may be a useful tool for investigating coat protein-dependent initiation of ilarvirus infection.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Land, S.; Allaben, W.T.; King, C.M.
1986-05-01
Mutagenic and carcinogenic aromatic amines are acetylated in most organisms. Acetyl CoA and arylhydroxamic acids can serve as acetyl donors for N-Acetylation of amines to yield stable amides, or by O-acetylation of hydroxylamine derivatives to produce reactive metabolites that can react covalently with nucleic acid. Polyclonal antibodies against rat arylhydroxamic acid, N,O-acyltransferase (AHAT) have been compared for their abilities to react with this enzyme and the acetyl CoA-dependent N-acetyltransferase (NAT) of the rat, rabbit, hamster, mouse and human. Liver cytosols were treated with increasing quantities of antibodies from immune or control rabbits. Immune complexes were removed by treatment with proteinmore » A-Sepharose before assay of nucleic acid adduct formation by AHAT activation of N-hydroxy-2-acetylaminofluorene and the acetylation of 2-aminofluorene by NAT. Both rat activities, the AHAT of the hamster and the NAT of the mouse and human were removed by this treatment. No decrease in NAT activity of hamster, or of either rabbit cytosol activity was observed. Neither mouse nor human liver has appreciable AHAT activity. These data support the idea that AHAT and NAT of rat, AHAT of hamster and NAT of mouse and human liver are immunochemically related, but that NAT of the hamster is an immunochemically distinct peptide.« less
Elsafi, Salah H; Alqahtani, Norah I; Zakary, Nawaf Y; Al Zahrani, Eidan M
2015-01-01
To study the performance of a single test using two fecal occult blood tests with colonoscopy for the detection of colorectal cancer (CRC) for the first time in Saudi Arabia to determine possible implications for the anticipated colorectal screening program. We compared the performance of guaiac and immunochemical fecal occult blood tests for the detection of CRC among patients of 50-74 years old attending two hospitals in the Eastern Region of Saudi Arabia. Samples of feces were collected from 257 asymptomatic patients and 20 cases of confirmed CRC, and they were tested simultaneously by the guaiac-based occult blood test and monoclonal antibody-based immunoassay kit. Colonoscopy was performed on all participants and the results were statistically analyzed with both positive and negative occult blood tests of both methods. Of the 277 subjects, 79 tested positive for occult blood with at least one method. Overall, the number of those with an occult blood-positive result by both tests was 39 (14.1%), while for 198 (71.5%), both tests were negative (P<0.0001); 40 (14.4%) samples showed a discrepant result. Colonoscopy data were obtained for all 277 patients. A total of three invasive cancers were detected among the screening group. Of the three, the guaiac test detected two cases, while the immunochemical test detected three of them. Of the 20 control cases, the guaiac test detected 13 CRC cases (P=0.03), while the immunochemical test detected 16 of them (P<0.0001). The sensitivity of guaiac and immunochemical tests for the detection of CRC in the screening group was 50.00% (95% confidence interval [CI] =6.76-93.24) and 75.00% (95% CI =19.41-99.37), respectively. For comparison, the sensitivity of the guaiac fecal occult blood test for detecting CRC among the control group was 65.00% (95% CI =40.78-84.61) while that of FIT was 80.00% (95% CI =56.34-94.27). The specificity of the guaiac and immunoassay tests was 77.87% (95% CI =72.24-82.83) and 90.12% (95% CI =85.76-93.50), respectively. The positive likelihood ratio of guaiac and immunochemical tests for the detection of CRC was 2.26 (95% CI =0.83-6.18) and 7.59 (95% CI =3.86-14.94), whereas the negative likelihood ratio was 0.64 (95% CI =0.24-1.71) and 0.28 (95% CI =0.05-1.52), respectively. The positive predictive values of guaiac and immunochemical tests were 3.45% (95% CI =0.426-11.91) and 10.71% (95% CI =2.27-28.23), respectively. There was no marked difference in the negative predictive values for both methods. The sensitivity of the fecal occult blood test by FIT was significantly higher for stages III and IV colorectal cancer than for stages I and II (P=0.01) and it was insignificant for the guaiac fecal occult blood test (P=0.07). In areas where other advance screening methods of CRC are not feasible, the use of FIT can be considered.
Sawa, Mitsuru
2011-03-01
1. Slit-lamp microscopy is a principal ophthalmic clinical method, because it provides microscopic findings of the anterior segment of the eye noninvasively. Its findings, however, are qualitative and there are large inter-observer variations in their evaluation. Furthermore, slit-lamp microscopy provides morphological findings, but a functional evaluation is difficult. We developed two novel methods that establish a qualitative methodology of the slit-lamp microscope and the pathophysiology of the anterior segment of the eye. One is the flare-cell photometer to evaluate flare and cells in the aqueous humor of the eye and the other is an immunohistochemical examination method using tear fluid to evaluate ocular surface disorders. The comprehensive evaluation of these studies is herein overviewed. 2. INNOVATION OF THE FLARE-CELL PHOTOMETER AND ITS CLINICAL SIGNIFICANCE: The breakdown of the blood-aqueous barrier (BAB) causes an increase in protein (flare) and leakage of blood cells (cell) into the aqueous humor of the eye and the severity of BAB breakdown has a positive correlation with the intensity of flare and cells. The flare and cells in the aqueous can be observed qualitatively by slit-lamp microscopy. These findings are primarily distinguished in optics by light scattering. Therefore, detection of the intensity of light scattering due to flare and cells can evaluate the BAB function. The flare-cell photometer comprises 3 novel components: a laser beam system as an incident light, a photomultiplier to detect scattered light intensity and a computer-assisted system to operate the whole system and analyze detected scattered light signals due to flare and cells. The instrument enables us to quantitatively analyze the flare and cells non-invasively and accurately with a wide dynamic measurement range, resulting in a repeated examination of each individual case. It also enables the evaluation of inflammation in the aqueous not only postoperatively but also in endogenous uveitis, evaluation of the effects of anti-inflammatory drugs on BAB and evaluation of aqueous humor dynamics. Furthermore, repeating the examination can minimize inter-individual variations and reduce the number of animals in animal experiments. 3. Sampling of tears can be performed noninvasively, but the obtainable volume is limited. Therefore, a determination of targeting biomarkers and a development of their micro-volume analysis methods play a crucial role in pathophysiological studies of the ocular surface. Targeting biomarkers should be determined according to the various specified bioactive substances such as eosinophil cationic protein (ECP), cytokines and others. A number of microvolume analysis methods, such as chemiluminescent enzyme immunoassay, immunochromatography, micro-array system and polymerase chain reaction method are used. Objective disorders in the studies include allergic conjunctivitis and infectious diseases such as herpetic keratitis. Quantitative evaluation methods for ECP concentration, antigen-specific secretory IgA in allergic diseases and herpetic keratitis, herpes simplex virus-DNA and cytokine and chemokine profile in tear fluid sampled by filter paper method were investigated. We developed a clinically applicable quantitative immunochemical method for ECP concentration in tear fluid. The results revealed that tear fluid analysis using the above mentioned methods is a clinically useful to investigate the pathophysiology of the ocular surface. 4. Laser flare-cell photometer and tear fluid analysis are potent clinical quantitative methods to investigate the pathophysiology of the anterior segment of the eye.
Amponsah, Amma; Nayak, Balunkeswar
2018-04-01
Recent studies have shown the need to improve soy allergen extraction using different extraction conditions to ensure more accurate results in allergen detection. This study investigated some of these extraction conditions to confirm that these methods, especially ultrasound-assisted extraction (UAE) and the use of Laemmli buffer instead of the conventional extraction with phosphate-buffered saline (PBS), could be helpful in improving the extraction step in allergen detection. Higher total soluble protein was obtained in all samples extracted with Laemmli buffer alone and in combination with ultrasound. For immunochemical detection of soy proteins by enzyme-linked immunosorbent assay (ELISA), comparable detection was observed in extracts from all extraction conditions in all commercial samples with the exception of table cracker and veggie burger, where significantly higher detection was seen in extracts from Laemmli buffer only. For the dry mix and cookie samples, the degree of soy protein detection with ELISA varied among the different extraction conditions, but overall, extraction with only Laemmli buffer showed higher detection. Laemmli buffer with conventional extraction and UAE may be better alternatives or additional extraction methods in soy allergen detection. Different food matrices performed differently (whether it was for the recovery of total proteins or detection by ELISA) under different extraction conditions. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
Metaxa, V; Lagoudaki, R; Meditskou, S; Thomareis, O; Oikonomou, L; Sakadamis, A
2014-01-01
Xenon and nitrous oxide have been shown to be neuroprotective in vivo and in vitro, but mainly in models of focal cerebral ischaemia. This study aimed to investigate whether the two gases are able to attenuate cerebral injury after global cerebral ischaemia. Adult male Wistar rats underwent bilateral common carotid artery occlusion and were ventilated for 1 hour with 21% O₂/78% N₂. They were then randomized to three groups which continued to receive atmospheric air, 50% N2O/50% O₂ and 50% Xe/50% O₂ for an additional period of 45 minutes. The number of ischaemic neurons, the cortical volume loss and the immunochemical and molecular expression of c-fos and MMP-9 were evaluated. Xenon reduced the number of ischaemic neurons in the cortex and CA1 hippocampal region (p < 0.001) and decreased the cortical volume loss (p < 0.01). Immunochemical induction of c-fos in the cortex was significantly suppressed (p < 0.01) after administration of xenon. The molecular analysis revealed significant effects of N2O and xenon administration on c-fos and MMP-9 expression. The data indicate that N2O and xenon administration is neuroprotective 1 hour after bilateral common carotid artery occlusion. These findings provide valuable evidence on the beneficial role of N2O and xenon in global cerebral injury.
Evaluation of apoptosis indexes in currently used oral alpha- blockers in prostate: a pilot study
Demir, Mehmet; Akin, Yigit; Terim, Kubra Asena Kapakin; Gulum, Mehmet; Buyukfirat, Evren; Ciftci, Halil; Yeni, Ercan
2018-01-01
ABSTRACT Objectives: Apoptosis effect of oral alpha-blockers is known in the prostate. Apoptosis index of silodosin has not been proved, yet. Aims are to present apoptosis index of silodosin in prostate and to compare this with other currently used alpha-blocker's apoptosis indexes together with their clinical effects. Materials and Methods: Benign prostatic hyperplasia (BPH) patients were enrolled among those admitted to urology outpatient clinic between June 2014 and June 2015. Study groups were created according to randomly prescribed oral alpha-blocker drugs as silodosin 8mg (Group 1; n=24), tamsulosin 0.4mg (Group 2; n=30), alfuzosin 10mg (Group 3; n=25), doxazosin 8mg (Group 4; n=22), terazosin 5mg (Group 5; n=15). Pa- tients who refused to use any alpha-blocker drug were included into Group 6 as control group (n=16). We investigated apoptosis indexes of the drugs in prostatic tissues that were taken from patient's surgery (transurethral resection of prostate) and/or prostate biopsies. Immunochemical dyeing, light microscope, and Image Processing and Analy- sis in Java were used for evaluations. Statistical significant p was p<0.05. Results: There were 132 patients with mean follow-up of 4.2±2.1 months. Pathologist researched randomly selected 10 areas in each microscope set. Group 1 showed statisti- cal significant difference apoptosis index in immunochemical TUNEL dyeing and im- age software (p<0.001). Moreover, we determined superior significant development in parameters as uroflowmetry, quality of life scores, and international prostate symptom score in Group 1. Conclusions: Silodosin has higher apoptosis effect than other alpha-blockers in prostate. Thus, clinic improvement with silodosin was proved by histologic studies. Besides, static factor of BPH may be overcome with creating apoptosis. PMID:29617082
Meulen, Miriam P van der; Kapidzic, Atija; Leerdam, Monique E van; van der Steen, Alex; Kuipers, Ernst J; Spaander, Manon C W; de Koning, Harry J; Hol, Lieke; Lansdorp-Vogelaar, Iris
2017-08-01
Background: Several studies suggest that test characteristics for the fecal immunochemical test (FIT) differ by gender, triggering a debate on whether men and women should be screened differently. We used the microsimulation model MISCAN-Colon to evaluate whether screening stratified by gender is cost-effective. Methods: We estimated gender-specific FIT characteristics based on first-round positivity and detection rates observed in a FIT screening pilot (CORERO-1). Subsequently, we used the model to estimate harms, benefits, and costs of 480 gender-specific FIT screening strategies and compared them with uniform screening. Results: Biennial FIT screening from ages 50 to 75 was less effective in women than men [35.7 vs. 49.0 quality-adjusted life years (QALY) gained, respectively] at higher costs (€42,161 vs. -€5,471, respectively). However, the incremental QALYs gained and costs of annual screening compared with biennial screening were more similar for both genders (8.7 QALYs gained and €26,394 for women vs. 6.7 QALYs gained and €20,863 for men). Considering all evaluated screening strategies, optimal gender-based screening yielded at most 7% more QALYs gained than optimal uniform screening and even resulted in equal costs and QALYs gained from a willingness-to-pay threshold of €1,300. Conclusions: FIT screening is less effective in women, but the incremental cost-effectiveness is similar in men and women. Consequently, screening stratified by gender is not more cost-effective than uniform FIT screening. Impact: Our conclusions support the current policy of uniform FIT screening. Cancer Epidemiol Biomarkers Prev; 26(8); 1328-36. ©2017 AACR . ©2017 American Association for Cancer Research.
Vleugels, Jasper L A; Greuter, Marjolein J E; Hazewinkel, Yark; Coupé, Veerle M H; Dekker, Evelien
2017-12-01
In an optical diagnosis strategy, diminutive polyps that are endoscopically characterized with high confidence are removed without histopathological analysis and distal hyperplastic polyps are left in situ. We evaluated the effectiveness and costs of optical diagnosis. Using the Adenoma and Serrated pathway to Colorectal CAncer (ASCCA) model, we simulated biennial fecal immunochemical test (FIT) screening in individuals aged 55 - 75 years. In this program, we compared an optical diagnosis strategy with current histopathology assessment of all diminutive polyps. Base-case assumptions included 76 % high-confidence predictions and sensitivities of 88 %, 91 %, and 88 % for endoscopically characterizing adenomas, sessile serrated polyps, and hyperplastic polyps, respectively. Outcomes were colorectal cancer burden, number of colonoscopies, life-years, and costs. Both the histopathology strategy and the optical diagnosis strategy resulted in 21 life-days gained per simulated individual compared with no screening. For optical diagnosis, €6 per individual was saved compared with the current histopathology strategy. These cost savings were related to a 31 % reduction in colonoscopies in which histopathology was needed for diminutive polyps. Projecting these results onto the Netherlands (17 million inhabitants), assuming a fully implemented FIT-based screening program, resulted in an annual undiscounted cost saving of € 1.7 - 2.2 million for optical diagnosis. Implementation of optical diagnosis in a FIT-based screening program saves costs without decreasing program effectiveness when compared with current histopathology analysis of all diminutive polyps. Further work is required to evaluate how endoscopists participating in a screening program should be trained, audited, and monitored to achieve adequate competence in optical diagnosis.
Evaluation of apoptosis indexes in currently used oral alpha-blockers in prostate: a pilot study.
Demir, Mehmet; Akin, Yigit; Terim, Kubra Asena Kapakin; Gulum, Mehmet; Buyukfirat, Evren; Ciftci, Halil; Yeni, Ercan
2018-01-01
Apoptosis effect of oral alpha-blockers is known in the prostate. Apoptosis index of silodosin has not been proved, yet. Aims are to present apoptosis index of silodosin in prostate and to compare this with other currently used alpha-blocker's apoptosis indexes together with their clinical effects. Benign prostatic hyperplasia (BPH) patients were enrolled among those admitted to urology outpatient clinic between June 2014 and June 2015. Study groups were created according to randomly prescribed oral alpha-blocker drugs as silodosin 8mg (Group 1; n=24), tamsulosin 0.4mg (Group 2; n=30), alfuzosin 10mg (Group 3; n=25), doxazosin 8mg (Group 4; n=22), terazosin 5mg (Group 5; n=15). Patients who refused to use any alpha-blocker drug were included into Group 6 as control group (n=16). We investigated apoptosis indexes of the drugs in prostatic tissues that were taken from patient's surgery (transurethral resection of prostate) and/or prostate biopsies. Immunochemical dyeing, light microscope, and Image Processing and Analysis in Java were used for evaluations. Statistical significant p was p<0.05. There were 132 patients with mean follow-up of 4.2±2.1 months. Pathologist researched randomly selected 10 areas in each microscope set. Group 1 showed statistical significant difference apoptosis index in immunochemical TUNEL dyeing and image software (p<0.001). Moreover, we determined superior significant development in parameters as uroflowmetry, quality of life scores, and international prostate symptom score in Group 1. Silodosin has higher apoptosis effect than other alpha-blockers in prostate. Thus, clinic improvement with silodosin was proved by histologic studies. Besides, static factor of BPH may be overcome with creating apoptosis. Copyright® by the International Brazilian Journal of Urology.
Lehmann, Sylvain; Hoofnagle, Andrew; Hochstrasser, Denis; Brede, Cato; Glueckmann, Matthias; Cocho, José A; Ceglarek, Uta; Lenz, Christof; Vialaret, Jérôme; Scherl, Alexander; Hirtz, Christophe
2013-05-01
Proteomics studies typically aim to exhaustively detect peptides/proteins in a given biological sample. Over the past decade, the number of publications using proteomics methodologies has exploded. This was made possible due to the availability of high-quality genomic data and many technological advances in the fields of microfluidics and mass spectrometry. Proteomics in biomedical research was initially used in 'functional' studies for the identification of proteins involved in pathophysiological processes, complexes and networks. Improved sensitivity of instrumentation facilitated the analysis of even more complex sample types, including human biological fluids. It is at that point the field of clinical proteomics was born, and its fundamental aim was the discovery and (ideally) validation of biomarkers for the diagnosis, prognosis, or therapeutic monitoring of disease. Eventually, it was recognized that the technologies used in clinical proteomics studies [particularly liquid chromatography-tandem mass spectrometry (LC-MS/MS)] could represent an alternative to classical immunochemical assays. Prior to deploying MS in the measurement of peptides/proteins in the clinical laboratory, it seems likely that traditional proteomics workflows and data management systems will need to adapt to the clinical environment and meet in vitro diagnostic (IVD) regulatory constraints. This defines a new field, as reviewed in this article, that we have termed quantitative Clinical Chemistry Proteomics (qCCP).
Chen, Sam Li-Sheng; Hsu, Chen-Yang; Yen, Amy Ming-Fang; Young, Graeme P; Chiu, Sherry Yueh-Hsia; Fann, Jean Ching-Yuan; Lee, Yi-Chia; Chiu, Han-Mo; Chiou, Shu-Ti; Chen, Hsiu-Hsi
2018-06-01
Background: Despite age and sex differences in fecal hemoglobin (f-Hb) concentrations, most fecal immunochemical test (FIT) screening programs use population-average cut-points for test positivity. The impact of age/sex-specific threshold on FIT accuracy and colonoscopy demand for colorectal cancer screening are unknown. Methods: Using data from 723,113 participants enrolled in a Taiwanese population-based colorectal cancer screening with single FIT between 2004 and 2009, sensitivity and specificity were estimated for various f-Hb thresholds for test positivity. This included estimates based on a "universal" threshold, receiver-operating-characteristic curve-derived threshold, targeted sensitivity, targeted false-positive rate, and a colonoscopy-capacity-adjusted method integrating colonoscopy workload with and without age/sex adjustments. Results: Optimal age/sex-specific thresholds were found to be equal to or lower than the universal 20 μg Hb/g threshold. For older males, a higher threshold (24 μg Hb/g) was identified using a 5% false-positive rate. Importantly, a nonlinear relationship was observed between sensitivity and colonoscopy workload with workload rising disproportionately to sensitivity at 16 μg Hb/g. At this "colonoscopy-capacity-adjusted" threshold, the test positivity (colonoscopy workload) was 4.67% and sensitivity was 79.5%, compared with a lower 4.0% workload and a lower 78.7% sensitivity using 20 μg Hb/g. When constrained on capacity, age/sex-adjusted estimates were generally lower. However, optimizing age/-sex-adjusted thresholds increased colonoscopy demand across models by 17% or greater compared with a universal threshold. Conclusions: Age/sex-specific thresholds improve FIT accuracy with modest increases in colonoscopy demand. Impact: Colonoscopy-capacity-adjusted and age/sex-specific f-Hb thresholds may be useful in optimizing individual screening programs based on detection accuracy, population characteristics, and clinical capacity. Cancer Epidemiol Biomarkers Prev; 27(6); 704-9. ©2018 AACR . ©2018 American Association for Cancer Research.
21 CFR 866.5340 - Ferritin immunological test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... affecting iron metabolism, such as hemochromatosis (iron overload) and iron deficiency amemia. (b... that consists of the reagents used to measure by immunochemical techniques the ferritin (an iron...
21 CFR 866.5340 - Ferritin immunological test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... affecting iron metabolism, such as hemochromatosis (iron overload) and iron deficiency amemia. (b... that consists of the reagents used to measure by immunochemical techniques the ferritin (an iron...
21 CFR 866.5340 - Ferritin immunological test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... affecting iron metabolism, such as hemochromatosis (iron overload) and iron deficiency amemia. (b... that consists of the reagents used to measure by immunochemical techniques the ferritin (an iron...
21 CFR 866.5340 - Ferritin immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... affecting iron metabolism, such as hemochromatosis (iron overload) and iron deficiency amemia. (b... that consists of the reagents used to measure by immunochemical techniques the ferritin (an iron...
Isotope labeled immunoassay for environmental chemical detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Velez, M.M.
1994-05-06
Altrazine, one of the most heavily used agricultural pesticides in North America, has been identified as a major groundwater contaminant in the U.S. Research provides evidence that under certain conditions atrazine and some of its derivatives may prove to be carcinogenic and mutagenic. Immunossays are one of the most powerful of all analytical immunochemical techniques. They employ a wide range of methods to detect and quantitate antigens or antibodies, and to study the structure of antigens. With the appropriate assay, they can be remarkably quick and easy, to yield information that would be difficult to determine by other techniques. Themore » development of the appropriate assay; however, requires clean and precise separation of antigens bound to antibodies from those that remain free. Sensitive assays depend on quantification of these bound antigens at very low levels. We are making direct and competitive immunoassays with atrazine and its antibodies using accelerator mass spectrometry (AMS) in order to obtain a sensitive immunoassay for atrazine in environmental samples.« less
Pham, Robyn; Cross, Suzanne; Fernandez, Bianca; Corson, Kathryn; Dillon, Kristen; Yackley, Coco; Davis, Melinda M
2017-01-01
Colorectal cancer (CRC) is the third leading cause of cancer death in the United States, yet 1 in 3 Americans have never been screened for CRC. Annual screening using fecal immunochemical tests (FITs) is often a preferred modality in populations experiencing CRC screening disparities. Although multiple studies evaluate the clinical effectiveness of FITs, few studies assess patient preferences toward kit characteristics. We conducted this community-led study to assess patient preferences for FIT characteristics and to use study findings in concert with clinical effectiveness data to inform regional FIT selection. We collaborated with local health system leaders to identify FITs and recruit age eligible (50 to 75 years), English or Spanish speaking community members. Participants completed up to 6 FITs and associated questionnaires and were invited to participate in a follow-up focus group. We used a sequential explanatory mixed-methods design to assess participant preferences and rank FIT kits. First, we used quantitative data from user testing to measure acceptability, ease of completion, and specimen adequacy through a descriptive analysis of 1) fixed response questionnaire items on participant attitudes toward and experiences with FIT kits, and 2) a clinical assessment of adherence to directions regarding collection, packaging, and return of specimens. Second, we analyzed qualitative data from focus groups to refine FIT rankings and gain deeper insight into the pros and cons associated with each tested kit. Seventy-six FITs were completed by 18 participants (Range, 3 to 6 kits per participant). Over half (56%, n = 10) of the participants were Hispanic and 50% were female (n = 9). Thirteen participants attended 1 of 3 focus groups. Participants preferred FITs that were single sample, used a probe and vial for sample collection, and had simple, large-font instructions with colorful pictures. Participants reported challenges using paper to catch samples, had difficulty labeling tests, and emphasized the importance of having care team members provide verbal instructions on test completion and follow-up support for patients with abnormal results. FIT rankings from most to least preferred were OC-Light, Hemosure iFOB Test, InSure FIT, QuickVue, OneStep+, and Hemoccult ICT. FIT characteristics influenced patient's perceptions of test acceptability and feasibility. Health system leaders, payers, and clinicians should select FITs that are both clinically effective and incorporate patient preferred test characteristics. Consideration of patient preferences may facilitate FIT return, especially in populations at higher risk for experiencing CRC screening disparities. © Copyright 2017 by the American Board of Family Medicine.
Fecal immunochemical test (FIT)
... the toilet water. Touch the brush on the space indicated on the test card. Add the brush ... DA, Levin TR; United States Multi-Society Task Force on Colorectal Cancer. Guidelines for colonoscopy surveillance after ...
21 CFR 866.5080 - Alpha-1-antichymotrypsin immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... immunochemical techniques alpha-1-antichymotrypsin (a protein) in serum, other body fluids, and tissues. Alpha-1-antichymotrypsin helps protect tissues against proteolytic (protein-splitting) enzymes released during infection...
Environmental immunochemical methods are responding to the changing needs of regulatory and monitoring programs and are meeting new analytical challenges as they arise. Immunoassays are being developed for screening multiple organophosphorous (OP) pesticides (0,0-diethyl thionate...
21 CFR 866.5570 - Lactoferrin immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... that consists of the reagents used to measure by immunochemical techniques the lactoferrin (an iron... fluids, and tissues. Measurement of lactoferrin may aid in the diagnosis of an inherited deficiency of...
21 CFR 866.5570 - Lactoferrin immunological test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... that consists of the reagents used to measure by immunochemical techniques the lactoferrin (an iron... fluids, and tissues. Measurement of lactoferrin may aid in the diagnosis of an inherited deficiency of...
21 CFR 866.5570 - Lactoferrin immunological test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... that consists of the reagents used to measure by immunochemical techniques the lactoferrin (an iron... fluids, and tissues. Measurement of lactoferrin may aid in the diagnosis of an inherited deficiency of...
21 CFR 866.5570 - Lactoferrin immunological test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... that consists of the reagents used to measure by immunochemical techniques the lactoferrin (an iron... fluids, and tissues. Measurement of lactoferrin may aid in the diagnosis of an inherited deficiency of...
Wong, Martin C S; Ching, Jessica Y L; Chan, Victor C W; Sung, Joseph J Y
2015-09-04
Faecal immunochemical tests (FITs) and colonoscopy are two common screening tools for colorectal cancer(CRC). Most cost-effectiveness studies focused on survival as the outcome, and were based on modeling techniques instead of real world observational data. This study evaluated the cost-effectiveness of these two tests to detect colorectal neoplastic lesions based on data from a 5-year community screening service. The incremental cost-effectiveness ratio (ICER) was assessed based on the detection rates of neoplastic lesions, and costs including screening compliance, polypectomy, colonoscopy complications, and staging of CRC detected. A total of 5,863 patients received yearly FIT and 4,869 received colonoscopy. Compared with FIT, colonoscopy detected notably more adenomas (23.6% vs. 1.6%) and advanced lesions or cancer (4.2% vs. 1.2%). Using FIT as control, the ICER of screening colonoscopy in detecting adenoma, advanced adenoma, CRC and a composite endpoint of either advanced adenoma or stage I CRC was US$3,489, US$27,962, US$922,762 and US$23,981 respectively. The respective ICER was US$3,597, US$439,513, -US$2,765,876 and US$32,297 among lower-risk subjects; whilst the corresponding figure was US$3,153, US$14,852, US$184,162 and US$13,919 among higher-risk subjects. When compared to FIT, colonoscopy is considered cost-effective for screening adenoma, advanced neoplasia, and a composite endpoint of advanced neoplasia or stage I CRC.
Wong, Martin CS; Ching, Jessica YL; Chan, Victor CW; Sung, Joseph JY
2015-01-01
Faecal immunochemical tests (FITs) and colonoscopy are two common screening tools for colorectal cancer(CRC). Most cost-effectiveness studies focused on survival as the outcome, and were based on modeling techniques instead of real world observational data. This study evaluated the cost-effectiveness of these two tests to detect colorectal neoplastic lesions based on data from a 5-year community screening service. The incremental cost-effectiveness ratio (ICER) was assessed based on the detection rates of neoplastic lesions, and costs including screening compliance, polypectomy, colonoscopy complications, and staging of CRC detected. A total of 5,863 patients received yearly FIT and 4,869 received colonoscopy. Compared with FIT, colonoscopy detected notably more adenomas (23.6% vs. 1.6%) and advanced lesions or cancer (4.2% vs. 1.2%). Using FIT as control, the ICER of screening colonoscopy in detecting adenoma, advanced adenoma, CRC and a composite endpoint of either advanced adenoma or stage I CRC was US$3,489, US$27,962, US$922,762 and US$23,981 respectively. The respective ICER was US$3,597, US$439,513, -US$2,765,876 and US$32,297 among lower-risk subjects; whilst the corresponding figure was US$3,153, US$14,852, US$184,162 and US$13,919 among higher-risk subjects. When compared to FIT, colonoscopy is considered cost-effective for screening adenoma, advanced neoplasia, and a composite endpoint of advanced neoplasia or stage I CRC. PMID:26338314
Análisis de Costo-Efectividad de las Estrategias de Tamización de Cáncer Colorrectal en Colombia.
Pinzon Florez, Carlos Eduardo; Rosselli, Diego; Gamboa Garay, Oscar Andrés
2012-12-01
To evaluate the cost-effectiveness of different screening strategies for colorectal cancer in Colombia. We designed a Markov model to compare the clinical and economic impact in terms of reducing the incidence and mortality from colorectal cancer (CRC). Six screening strategies for adults were compared: fecal occult blood (FOBT) immunochemical and guaiac type, conventional colonoscopy, flexible sigmoidoscopy, and FOBT guaiac and immunochemical type more sigmoidoscopy. We used the third-party payer perspective, including only direct costs, the time horizon was the life expectancy of the Colombian population. We estimated cost-effectiveness ratios (CERs) and incremental cost-effectiveness (ICER). Were performed deterministic sensitivity analysis and probabilistic. We applied a discount rate of 3% in the costs and health outcomes. The screening strategy more cost-effective was the FOBT biennial guaiac type. The cost per life year gained was US$10,347.37, US$18,380.64, and US$45,158.05. For FOBT guaiac biennial, FOBT guaiac annual and FOBT inmunoquímica biennial respectively. The ICER is sensitive to the percentage of false positive test for FOBT guaiac type values greater than 10%, and the cost of the test. The screening strategy more cost-effective for Colombia is the FOBT biennial guaiac type, using as a threshold the gross domestic product (GDP) per capita in Colombia. Copyright © 2012 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Chen, A Xiong; Xie, Guang Cheng; Pan, Dong; DU, Ya Rong; Pang, Li Li; Song, Jing Dong; Duan, Zhao Jun; Hu, Bu Rong
2018-02-01
Newly identified human rhinovirus C (HRV-C) and human bocavirus (HBoV) cannot propagate in vitro in traditional cell culture models; thus obtaining knowledge about these viruses and developing related vaccines are difficult. Therefore, it is necessary to develop a novel platform for the propagation of these types of viruses. A platform for culturing human airway epithelia in a three-dimensional (3D) pattern using Matrigel as scaffold was developed. The features of 3D culture were identified by immunochemical staining and transmission electron microscopy. Nucleic acid levels of HRV-C and HBoV in 3D cells at designated time points were quantitated by real-time polymerase chain reaction (PCR). Levels of cytokines, whose secretion was induced by the viruses, were measured by ELISA. Properties of bronchial-like tissues, such as the expression of biomarkers CK5, ZO-1, and PCK, and the development of cilium-like protuberances indicative of the human respiration tract, were observed in 3D-cultured human airway epithelial (HAE) cultures, but not in monolayer-cultured cells. Nucleic acid levels of HRV-C and HBoV and levels of virus-induced cytokines were also measured using the 3D culture system. Our data provide a preliminary indication that the 3D culture model of primary epithelia using a Matrigel scaffold in vitro can be used to propagate HRV-C and HBoV. Copyright © 2018 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.
Watanabe, Eiki; Kobara, Yuso; Miyake, Shiro
2013-06-01
With the aim of expanding the applicability of a kit-based enzyme-linked immunosorbent assay (ELISA) for the neonicotinoid insecticide thiamethoxam, the ELISA was newly applied to three kinds of agricultural samples (green pepper, eggplant and spinach). To offer the ELISA as a screening analysis for thiamethoxam residues, a rapid and simple method of extraction by hand-shaking was used, and speed-up and simplification of the sample treatment before the ELISA analysis were examined. Finally, the validity of the ELISA combined with the proposed extraction method was verified against a reference high-performance liquid chromatography (HPLC) method using real-world agricultural samples. There were no marked matrix effects derived from green pepper and eggplant extracts. On the other hand, although the effect due to a pigment in spinach extract on the assay performance was significant, it was effectively avoided by increasing the dilution level of the spinach extract. For thiamethoxam-spiked samples, acceptable recoveries of 97.9-109.1% and coefficients of variation of 0.3-11.5% were obtained. Inspection of the validity of the ELISA by comparison with the reference HPLC method showed that the two analytical results were very similar, and a high correlation was found between them (r>0.997). The evaluated ELISA combined with hand-shaking extraction provided a rapid and simple screening analysis that was quantitative and reliable for the detection of thiamethoxam in complex agricultural products. © 2012 Society of Chemical Industry.
Laboratory screening markers in gastroenterology--state of the art.
Kocna, Petr; Vanickova, Zdislava; Zima, Tomas
2013-06-01
Screening tests for gastrointestinal diseases acceptable for population with a high sensitivity and high specificity can now be offered by clinical laboratories. This paper summarizes major recent advances in this area of laboratory medicine. Relevant articles published within the last 5 years in the NLM (National Library of Medicine) PubMed - Medline database covering the three gastrointestinal diseases - colorectal cancer, coeliac disease, and atrophic gastritis were included for this overview. In Europe, colorectal cancer (CRCA) is the second most frequent malignant disease. Quantitative immunochemical analysis of the stool for haemoglobin provides the best screening test to date, with both sensitivity and specificity approaching 95%. Even though coeliac disease (CD) affects approximately 1% of the general population, it remains largely unrecognised. Recommended methods for screening currently involve the detection of IgA and IgG antibodies against tissue transglutaminase and deamidated gliadin peptide. Evaluations of screening are now discussed for other diseases of the gastrointestinal tract - such as chronic atrophic gastritis (CAG), and inflammatory bowel disease (IBD). Detection of infection by Helicobacter pylori and stomach-specific plasmatic biomarkers, especially pepsinogen I/II ratio, could help with the prevention of gastric carcinomas. The use of faecal calprotectin as a screening test could substantially reduce the number of invasive methods necessary for the diagnostic work-up of patients with IBD. Screening tests for CRCA and CD have been used worldwide for many years. Screening strategies for gastrointestinal diseases are suggested in the text, based on recent basic science, clinical papers as well as our own experience.
Strategies for the Determination of Plant Hormones.
ERIC Educational Resources Information Center
Davis, Gregory C.; And Others
1985-01-01
Describes methods for isolating, purifying, and analyzing plant hormones (molecules involved in plant growth regulation and development). The presentation reflects the historical development of analyses, beginning with bioassays and ending with novel immunochemical assays. (JN)
IMMUNOCHEMICAL DETERMINATION OF DIOXINS IN SEDIMENT SAMPLES
Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) are considered highly toxic contaminants with the environmental monitoring of these compounds being of great importance. Immunoassay procedures such as the enzyme-linked immunosorbent assay (ELIS...
Sarabhai, Swati; Indrani, D; Vijaykrishnaraj, M; Milind; Arun Kumar, V; Prabhasankar, P
2015-06-01
The effect of 5, 7.5 and 10 % protein concentrates namely soya protein isolate (SPI), whey protein concentrate (WPC) and addition of 0.5 % emulsifiers such as glycerol monostearate (GMS), sodium stearoyl- 2- lactylate (SSL) and lecithin (LEC) on the rheological, sensory and textural characteristics of cookies with rice flour and its immunochemical validation was studied. The results showed that the use of 7.5 % SPI/WPC along with GMS significantly improved the quality characteristics of cookies with rice flour. Dot-Blot and Western-blot studies of cookies with 7.5 % of SPI or WPC confirmed that the anti-gliadin did not recognize these proteins. Carry- through process using ELISA kit confirmed that gluten was within the permissible limit in all the stages of processing and hence these cookies can be consumed by people suffering from celiac disease.
McCarty, Maclyn
1959-01-01
A bacterial substance has been described which gives a precipitin reaction with certain antisera to Group A streptococci. The precipitating antigen is present in various Gram-positive bacteria, including most hemolytic streptococci, staphylococci, and aerobic sporulating bacilli. It is not present in any of the Gram-negative species examined or in pneumococci, clostridia, or corynebacteria. Analysis of purified preparations obtained from Group A streptococci indicates that the antigen is a simple polymer of glycerophosphate. The identification has been confirmed by immunochemical studies, including precipitin tests and specific inhibition with synthetic polyglycerophosphates. In addition, the infrared spectra of bacterial and synthetic polyglycerophosphate are shown to be closely similar. Immunochemical analysis suggests that the amount of polyglycerophosphate present in Group A streptococci and staphylococci is approximately 1 per cent of the dry weight of the cells. The cellular localization and function of the polyglycerophosphate have not been established. PMID:13641562
21 CFR 866.5260 - Complement C3b inactivator immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... immunochemical techniques the complement C3b inactivator (a plasma protein) in serum. Complement is a group of serum proteins that destroy infectious agents. Measurement of complement C3b inactivator aids in the...
21 CFR 866.5640 - Infectious mononucleosis immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Infectious mononucleosis immunological test system....5640 Infectious mononucleosis immunological test system. (a) Identification. An infectious... immunochemical techniques heterophile antibodies frequently associated with infectious mononucleosis in serum...
21 CFR 866.5640 - Infectious mononucleosis immunological test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Infectious mononucleosis immunological test system....5640 Infectious mononucleosis immunological test system. (a) Identification. An infectious... immunochemical techniques heterophile antibodies frequently associated with infectious mononucleosis in serum...
21 CFR 866.5640 - Infectious mononucleosis immunological test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Infectious mononucleosis immunological test system....5640 Infectious mononucleosis immunological test system. (a) Identification. An infectious... immunochemical techniques heterophile antibodies frequently associated with infectious mononucleosis in serum...
21 CFR 866.5640 - Infectious mononucleosis immunological test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Infectious mononucleosis immunological test system....5640 Infectious mononucleosis immunological test system. (a) Identification. An infectious... immunochemical techniques heterophile antibodies frequently associated with infectious mononucleosis in serum...
21 CFR 866.5640 - Infectious mononucleosis immunological test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Infectious mononucleosis immunological test system....5640 Infectious mononucleosis immunological test system. (a) Identification. An infectious... immunochemical techniques heterophile antibodies frequently associated with infectious mononucleosis in serum...
IMMUNOCHEMICAL DETERMINATION OF DIOXINS IN SEDIMENT AND SERUM SAMPLES
Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) are considered highly toxic contaminants and the environmental and biological monitoring of these compounds is of great concern. Immunoassays may be used as screening methods to satisfy the gro...
21 CFR 866.5260 - Complement C3b inactivator immunological test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... immunochemical techniques the complement C3b inactivator (a plasma protein) in serum. Complement is a group of serum proteins that destroy infectious agents. Measurement of complement C3b inactivator aids in the...
21 CFR 866.5260 - Complement C3b inactivator immunological test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... immunochemical techniques the complement C3b inactivator (a plasma protein) in serum. Complement is a group of serum proteins that destroy infectious agents. Measurement of complement C3b inactivator aids in the...
21 CFR 866.5260 - Complement C3b inactivator immunological test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... immunochemical techniques the complement C3b inactivator (a plasma protein) in serum. Complement is a group of serum proteins that destroy infectious agents. Measurement of complement C3b inactivator aids in the...
21 CFR 866.5250 - Complement C2 inhibitor (inactivator) immunological test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... the reagents used to measure by immunochemical techniques the complement C1 inhibitor (a plasma protein) in serum. Complement C1 inhibitor occurs normally in plasma and blocks the action of the C1...
21 CFR 866.5250 - Complement C2 inhibitor (inactivator) immunological test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... the reagents used to measure by immunochemical techniques the complement C1 inhibitor (a plasma protein) in serum. Complement C1 inhibitor occurs normally in plasma and blocks the action of the C1...
21 CFR 866.5250 - Complement C2 inhibitor (inactivator) immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... the reagents used to measure by immunochemical techniques the complement C1 inhibitor (a plasma protein) in serum. Complement C1 inhibitor occurs normally in plasma and blocks the action of the C1...
21 CFR 866.5250 - Complement C 2 inhibitor (inactivator) immunological test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... the reagents used to measure by immunochemical techniques the complement C1 inhibitor (a plasma protein) in serum. Complement C1 inhibitor occurs normally in plasma and blocks the action of the C1...
21 CFR 866.5250 - Complement C 2 inhibitor (inactivator) immunological test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... the reagents used to measure by immunochemical techniques the complement C1 inhibitor (a plasma protein) in serum. Complement C1 inhibitor occurs normally in plasma and blocks the action of the C1...
Szilagyi, Andrew; Xue, Xiaoqing
2017-01-01
Stool tests can predict advanced neoplasms prior to colonoscopy. Results of immunochemical stool tests to predict findings at colonoscopy for various indications are less often reported. We compared pre-colonoscopy stool tests with findings in patients undergoing colonoscopy for different indications. Charts of patients undergoing elective or semi-urgent colonoscopy were reviewed. Comparison of adenoma detection rates and pathological findings was made between prescreened and non-prescreened, and between stool-positive and stool-negative cases. Demographics, quality of colonoscopy, and pathological findings were recorded. Odds ratios (ORs) and 95% confidence intervals (CIs) were assessed. Statistical significance was accepted at p ≤0.05. Charts of 325 patients were reviewed. Among them, stool tests were done on 144 patients: 114 were negative and 30 were positive. Findings were similar in the pretest and non-pretest groups. Detection of advanced adenomas per patient was higher in the stool-positive group compared to the stool-negative group (23.4% vs 3.5%, p =0.0016, OR =7.6 [95% CI: 2-29.3]). Five advanced adenomas (without high-grade dysplasia or adenocarcinoma) and several cases of multiple adenomas were missed in the negative group. Sensitivity and specificity for advanced polyps was 63.6% and 82.7%, respectively. The negative predictive value was 96.5%. Male gender was independently predictive of any adenoma. The stool immunochemical test best predicted advanced neoplasms and had a high negative predictive value in this small cohort. Whether this test can be applied to determine the need for colonoscopy in groups other than average risk would require more studies.
Grazzini, Grazia; Ventura, Leonardo; Rubeca, Tiziana; Rapi, Stefano; Cellai, Filippo; Di Dia, Pietro P; Mallardi, Beatrice; Mantellini, Paola; Zappa, Marco; Castiglione, Guido
2017-07-01
Haemoglobin (Hb) stability in faecal samples is an important issue in colorectal cancer screening by the faecal immunochemical test (FIT) for Hb. This study evaluated the performance of the FIT-Hb (OC-Sensor Eiken) used in the Florence screening programme by comparing two different formulations of the buffer, both in an analytical and in a clinical setting. In the laboratory simulation, six faecal pools (three in each buffer type) were stored at different temperatures and analysed eight times in 10 replicates over 21 days. In the clinical setting, 7695 screenees returned two samples, using both the old and the new specimen collection device (SCD). In the laboratory simulation, 5 days from sample preparation with the buffer of the old SCD, the Hb concentration decreased by 40% at room temperature (25°C, range 22-28°C) and up to 60% at outside temperature (29°C, range 16-39°C), whereas with the new one, Hb concentration decreased by 10%. In the clinical setting, a higher mean Hb concentration with the new SCD compared with the old one was found (6.3 vs. 5.0 µg Hb/g faeces, respectively, P<0.001); no statistically significant difference was found in the probability of having a positive result in the two SCDs. Better Hb stability was observed with the new buffer under laboratory conditions, but no difference was found in the clinical performance. In our study, only marginal advantages arise from the new buffer. Improvements in sample stability represent a significant target in the screening setting.
Smith, David H; O'Keeffe Rosetti, Maureen; Mosen, David M; Rosales, A Gabriela; Keast, Erin; Perrin, Nancy; Feldstein, Adrianne C; Levin, Theodore R; Liles, Elizabeth G
2018-06-21
Colorectal cancer (CRC) causes more than 50,000 deaths each year in the United States but early detection through screening yields survival gains; those diagnosed with early stage disease have a 5-year survival greater than 90%, compared to 12% for those diagnosed with late stage disease. Using data from a large integrated health system, this study evaluates the cost-effectiveness of fecal immunochemical testing (FIT), a common CRC screening tool. A probabilistic decision-analytic model was used to examine the costs and outcomes of positive test results from a 1-FIT regimen compared with a 2-FIT regimen. The authors compared 5 diagnostic cutoffs of hemoglobin concentration for each test (for a total of 10 screening options). The principal outcome from the analysis was the cost per additional advanced neoplasia (AN) detected. The authors also estimated the number of cancers detected and life-years gained from detecting AN. The following costs were included: program management of the screening program, patient identification, FIT kits and their processing, and diagnostic colonoscopy following a positive FIT. Per-person costs ranged from $33 (1-FIT at 150ng/ml) to $92 (2-FIT at 50ng/ml) across screening options. Depending on willingness to pay, the 1-FIT 50 ng/ml and the 2-FIT 50 ng/ml are the dominant strategies with cost-effectiveness of $11,198 and $28,389, respectively, for an additional AN detected. The estimates of cancers avoided per 1000 screens ranged from 1.46 to 4.86, depending on the strategy and the assumptions of AN to cancer progression.
Suehiro, Yutaka; Hashimoto, Shinichi; Higaki, Shingo; Fujii, Ikuei; Suzuki, Chieko; Hoshida, Tomomi; Matsumoto, Toshihiko; Yamaoka, Yuko; Takami, Taro; Sakaida, Isao; Yamasaki, Takahiro
2018-03-30
Although methylated TWIST1 is a biomarker of colorectal neoplasia, its detection from serum samples is very difficult by conventional bisulfite-based methylation assays. Therefore, we have developed a new methylation assay that enables counting of even one copy of a methylated gene in a small DNA sample amount without DNA bisulfite treatment. We performed this study to evaluate the sensitivity and specificity of serum DNA testing by the new methylation assay in combination with and without the fecal immunochemical test for hemoglobin for the detection of colorectal neoplasia. This study comprised 113 patients with colorectal neoplasia and 25 control individuals. For the new methylation assay, DNA was treated in two stages with methylation-sensitive restriction enzymes, followed by measurement of copy numbers of hTERT and methylated TWIST1 by multiplex droplet digital PCR. The fecal immunochemical test had a sensitivity of 8.0% for non-advanced adenoma, 24.3% for advanced adenoma, and 44.4% for colorectal cancer, and a specificity of 88.0%. The new assay had a sensitivity of 36.0% for non-advanced adenoma, 30.0% for advanced adenoma, and 44.4% for colorectal cancer, and a specificity of 92.0%. Combination of the both tests increased the sensitivity to 40.0%, 45.7%, and 72.2% for the detection of non-advanced adenoma, advanced adenoma, and colorectal cancer, respectively, and resulted in a specificity of 84.0%. Combination of both tests may provide an alternative screening strategy for colorectal neoplasia including potentially precancerous lesions and colorectal cancer.
Dai, Cong; Jiang, Min; Sun, Ming-Jun; Cao, Qin
2018-05-01
Fecal immunochemical test (FIT) is a promising marker for assessment of inflammatory bowel disease activity. However, the utility of FIT for predicting mucosal healing (MH) of ulcerative colitis (UC) patients has yet to be clearly demonstrated. The objective of our study was to perform a diagnostic test accuracy test meta-analysis evaluating the diagnostic accuracy of FIT in predicting MH of UC patients. We systematically searched the databases from inception to November 2017 that evaluated MH in UC. The methodological quality of each study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies checklist. The extracted data were pooled using a summary receiver operating characteristic curve model. Random-effects model was used to summarize the diagnostic odds ratio, sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio. Six studies comprising 625 UC patients were included in the meta-analysis. The pooled sensitivity and specificity values for predicting MH in UC were 0.77 (95% confidence interval [CI], 0.72-0.81) and 0.81 (95% CI, 0.76-0.85), respectively. The FIT level had a high rule-in value (positive likelihood ratio, 3.79; 95% CI, 2.85-5.03) and a moderate rule-out value (negative likelihood ratio, 0.26; 95% CI, 0.16-0.43) for predicting MH in UC. The results of the receiver operating characteristic curve analysis (area under the curve, 0.88; standard error of the mean, 0.02) and diagnostic odds ratio (18.08; 95% CI, 9.57-34.13) also revealed improved discrimination for identifying MH in UC with FIT concentration. Our meta-analysis has found that FIT is a simple, reliable non-invasive marker for predicting MH in UC patients. © 2018 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.
21 CFR 866.5090 - Antimitochondrial antibody immunological test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... immunochemical techniques the antimitochondrial antibodies in human serum. The measurements aid in the diagnosis of diseases that produce a spectrum of autoantibodies (antibodies produced against the body's own... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test...
21 CFR 866.5090 - Antimitochondrial antibody immunological test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... immunochemical techniques the antimitochondrial antibodies in human serum. The measurements aid in the diagnosis of diseases that produce a spectrum of autoantibodies (antibodies produced against the body's own... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test...
21 CFR 866.5090 - Antimitochondrial antibody immunological test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... immunochemical techniques the antimitochondrial antibodies in human serum. The measurements aid in the diagnosis of diseases that produce a spectrum of autoantibodies (antibodies produced against the body's own... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test...
Ochratoxin A Detection on Antibody- Immobilized on BSA-Functionalized Gold Electrodes.
Badea, Mihaela; Floroian, Laura; Restani, Patrizia; Cobzac, Simona Codruta Aurora; Moga, Marius
2016-01-01
Ochratoxin A (OTA)-a toxin produced by Aspergillus carbonarius, Aspergillus ochraceus, and Penicillium verrucosum-is one of the most-abundant food-contaminating mycotoxins. To avoid the risk of OTA consumption for humans and animals, the rapid detection and quantitation of OTA level in different commodities are of great importance. In this work, an impedimetric immunosensor for ochratoxin A (OTA) detection, a common toxic botanical contaminant, was developed via the immobilization of anti-OTA antibody on bovine serum albumin modified gold electrodes. A four-step reaction protocol was tested to modify the gold electrode and obtain the sensing substrate. All the steps of the immunosensor elaboration and also the immunochemical reaction between surface-bound antibody and ochratoxin A were analyzed using cyclic voltammetry and electrochemical impedance spectroscopy. Modification of the impedance due to the specific antigen-antibody reaction at immunosensor surface, was used in order to detect ochratoxin A. Linear proportionality of the charge transfer resistance to the concentration of OTA allows ochratoxin A detection in the range of 2.5-100 ng/mL.
Tinmouth, Jill; Lansdorp-Vogelaar, Iris; Allison, James E
2015-08-01
Although colorectal cancer (CRC) is a common cause of cancer-related death, it is fortunately amenable to screening with faecal tests for occult blood and endoscopic tests. Despite the evidence for the efficacy of guaiac-based faecal occult blood tests (gFOBT), they have not been popular with primary care providers in many jurisdictions, in part because of poor sensitivity for advanced colorectal neoplasms (advanced adenomas and CRC). In order to address this issue, high sensitivity gFOBT have been recommended, however, these tests are limited by a reduction in specificity compared with the traditional gFOBT. Where colonoscopy is available, some providers have opted to recommend screening colonoscopy to their patients instead of faecal testing, as they believe it to be a better test. Newer methods for detecting occult human blood in faeces have been developed. These tests, called faecal immunochemical tests (FIT), are immunoassays specific for human haemoglobin. FIT hold considerable promise over the traditional guaiac methods including improved analytical and clinical sensitivity for CRC, better detection of advanced adenomas, and greater screenee participation. In addition, the quantitative FIT are more flexible than gFOBT as a numerical result is reported, allowing customisation of the positivity threshold. When compared with endoscopy, FIT are less sensitive for the detection of advanced colorectal neoplasms when only one time testing is applied to a screening population; however, this is offset by improved participation in a programme of annual or biennial screens and a better safety profile. This review will describe how gFOBT and FIT work and will present the evidence that supports the use of FIT over gFOBT, including the cost-effectiveness of FIT relative to gFOBT. Finally, specific issues related to FIT implementation will be discussed, particularly with respect to organised CRC screening programmes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Detection of phytoplasmas of temperate fruit trees.
Laimer, Margit
2009-01-01
Phytoplasmas are associated with hundreds of plant diseases globally. Many fruit tree phytoplasmas are transmitted by insect vectors or grafting, are considered quarantine organisms and a major economic threat to orchards. Diagnosis can be difficult, but immunochemical and molecular methods have been developed.
Smith, Jerome P; Sammons, Deborah L; Robertson, Shirley A; Pretty, Jack; Debord, D Gayle; Connor, Thomas H; Snawder, John
2015-01-01
Objectives Contamination of workplace surfaces by antineoplastic drugs presents an exposure risk for healthcare workers. Traditional instrumental methods to detect contamination such as liquid chromatography-tandem mass spectrometry (LC-MS/MS) are sensitive and accurate but expensive. Since immunochemical methods may be cheaper and faster than instrumental methods, we wanted to explore their use for routine drug residue detection for preventing worker exposure. Methods In this study we examined the feasibility of using fluorescence covalent microbead immunosorbent assay (FCMIA) for simultaneous detection and semi-quantitative measurement of three antineoplastic drugs (5-fluorouracil, paclitaxel, and doxorubicin). The concentration ranges for the assay were 0–1000 ng/ml for 5-fluorouracil, 0–100 ng/ml for paclitaxel, and 0–2 ng/ml for doxorubicin. The surface sampling technique involved wiping a loaded surface with a swab wetted with wash buffer, extracting the swab in storage/blocking buffer, and measuring drugs in the extract using FCMIA. Results There was no significant cross reactivity between these drugs at the ranges studied indicated by a lack of response in the assay to cross analytes. The limit of detection (LOD) for 5-fluorouracil on the surface studied was 0.93 ng/cm2 with a limit of quantitation (LOQ) of 2.8 ng/cm2, the LOD for paclitaxel was 0.57 ng/cm2 with an LOQ of 2.06 ng/cm2, and the LOD for doxorubicin was 0.0036 ng/cm2 with an LOQ of 0.013 ng/cm2. Conclusion The use of FCMIA with a simple sampling technique has potential for low cost simultaneous detection and semi-quantitative measurement of surface contamination from multiple antineoplastic drugs. PMID:25293722
Colorectal Cancer Screening Initiation After Age 50 Years in an Organized Program.
Fedewa, Stacey A; Corley, Douglas A; Jensen, Christopher D; Zhao, Wei; Goodman, Michael; Jemal, Ahmedin; Ward, Kevin C; Levin, Theodore R; Doubeni, Chyke A
2017-09-01
Recent studies report racial disparities among individuals in organized colorectal cancer (CRC) programs; however, there is a paucity of information on CRC screening utilization by race/ethnicity among newly age-eligible adults in such programs. This was a retrospective cohort study among Kaiser Permanente Northern California enrollees who turned age 50 years between 2007 and 2012 (N=138,799) and were served by a systemwide outreach and facilitated in-reach screening program based primarily on mailed fecal immunochemical tests to screening-eligible people. Kaplan-Meier and Cox model analyses were used to estimate differences in receipt of CRC screening in 2015-2016. Cumulative probabilities of CRC screening within 1 and 2 years of subjects' 50th birthday were 51% and 73%, respectively. Relative to non-Hispanic whites, the likelihood of completing any CRC screening was similar in blacks (hazard ratio, 0.98; 95% CI=0.96, 1.00); 5% lower in Hispanics (hazard ratio, 0.95; 95% CI=0.93, 0.96); and 13% higher in Asians (hazard ratio, 1.13; 95% CI=1.11, 1.15) in adjusted analyses. Fecal immunochemical testing was the most common screening modality, representing 86% of all screening initiations. Blacks and Hispanics had lower receipt of fecal immunochemical testing in adjusted analyses. CRC screening uptake was high among newly screening-eligible adults in an organized CRC screening program, but Hispanics were less likely to initiate screening near age 50 years than non-Hispanic whites, suggesting that cultural and other individual-level barriers not addressed within the program likely contribute. Future studies examining the influences of culturally appropriate and targeted efforts for screening initiation are needed. Copyright © 2017 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.
Colorectal cancer screening of immigrants to Italy. Figures from the 2013 National Survey.
Turrin, Anna; Zorzi, Manuel; Giorgi Rossi, Paolo; Senore, Carlo; Campari, Cinzia; Fedato, Chiara; Naldoni, Carlo; Anghinoni, Emanuela; Carrozzi, Giuliano; Sassoli De' Bianchi, Priscilla; Zappa, Marco
2015-12-01
Colorectal cancer screening programmes in Italy invite 50-69-year-old residents for a faecal immunochemical test every two years, regardless of their citizenship. The 2013 National Survey on Italian colorectal cancer screening programmes compared immigrants born in low- or middle-income countries with subjects who were born in Italy, by collecting aggregated data on compliance, faecal immunochemical test results, compliance with colonoscopy, detected lesions and stage at diagnosis separately for Italians and immigrants. Overall, 85 screening programmes invited 3,292,451 subjects, of whom 192,629 had been born abroad (5.9%). Compliance with invitation was lower in immigrants (34.3% vs. 51.3% in Italians), with p<0.001. Compliance was higher in females, regardless of the country of birth, in the youngest age group of immigrants but in the oldest of Italians. Immigrants showed a borderline excess of standardised faecal immunochemical test positivity rate at first screening (5.4% vs. 5.1% in Italians, p=0.05) and a significant excess at repeat screenings (4.8% vs. 4.4%, p=0.002). The detection rates for carcinoma and advanced adenomas were lower in immigrants than in Italians at first screening (respectively 1.34‰ vs. 1.62‰ and 8.41‰ vs. 9.25‰) - although the differences were not statistically significant - but not at repeat screening (respectively 1.06‰ vs. 0.98‰ and 6.90‰ vs. 6.79‰). Migrants showed a lower compliance with screening than Italians. The prevalence of neoplasia was lower at first screening and similar to the Italians' at repeat screenings. Copyright © 2015 Elsevier Inc. All rights reserved.
21 CFR 866.5200 - Carbonic anhydrase B and C immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test... immunochemical techniques specific carbonic anhydrase protein molecules in serum and other body fluids. Measurements of carbonic anhydrase B and C aid in the diagnosis of abnormal hemoglobin metabolism. (b...
21 CFR 866.5200 - Carbonic anhydrase B and C immunological test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test... immunochemical techniques specific carbonic anhydrase protein molecules in serum and other body fluids. Measurements of carbonic anhydrase B and C aid in the diagnosis of abnormal hemoglobin metabolism. (b...
21 CFR 866.5890 - Inter-alpha trypsin inhibitor immunological test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test... measure by immunochemical techniques the inter-alpha trypsin inhibitor (a protein) in serum and other body fluids. Measurement of inter-alpha trypsin inhibitor may aid in the diagnosis of acute bacterial...
21 CFR 866.5200 - Carbonic anhydrase B and C immunological test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test... immunochemical techniques specific carbonic anhydrase protein molecules in serum and other body fluids. Measurements of carbonic anhydrase B and C aid in the diagnosis of abnormal hemoglobin metabolism. (b...
21 CFR 866.5890 - Inter-alpha trypsin inhibitor immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test... measure by immunochemical techniques the inter-alpha trypsin inhibitor (a protein) in serum and other body fluids. Measurement of inter-alpha trypsin inhibitor may aid in the diagnosis of acute bacterial...
21 CFR 866.5890 - Inter-alpha trypsin inhibitor immunological test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test... measure by immunochemical techniques the inter-alpha trypsin inhibitor (a protein) in serum and other body fluids. Measurement of inter-alpha trypsin inhibitor may aid in the diagnosis of acute bacterial...
21 CFR 866.5890 - Inter-alpha trypsin inhibitor immunological test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test... measure by immunochemical techniques the inter-alpha trypsin inhibitor (a protein) in serum and other body fluids. Measurement of inter-alpha trypsin inhibitor may aid in the diagnosis of acute bacterial...
21 CFR 866.5200 - Carbonic anhydrase B and C immunological test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test... immunochemical techniques specific carbonic anhydrase protein molecules in serum and other body fluids. Measurements of carbonic anhydrase B and C aid in the diagnosis of abnormal hemoglobin metabolism. (b...
Hollins, P J; Nathan, M M
1979-01-01
Insulins of differing species, together with chemically modified insulins, were used in cross-reactivity experiments employing selected antisera raised to ox insulin in the Harley guinea-pig. The immunogen had been administered as a water-in-oil emulsion, using H. pertussis vaccine as adjuvant. Antibody was generated by determinants in the C-terminus of the B chain plus the adjacent N-terminus of the A chain, in the central core of the A chain (A8-A14 region) and in its anti-parallel N-terminus of the B chain. From this antibody pool chemically modified ox insulin selected antibody to unaltered determinants. The immunochemical data were compatible with monomeric ox insulin being immunogenic, the immunogen perhaps being recognized by the immune system in the form of the Molecule-II rather than the Molecule-I of the dimer pair (as originally suggested by X-ray crystallographic data). PMID:93526
Laidler, P M; Steczko, J
1986-01-01
Arylsulphatase A (EC 3.1.6.1.) from urine was inactivated with potassium ferrate, a strong oxidizing agent. The inhibition could be prevented by competitive inhibitors, tetraborate and orthophosphate. Tetraborate which was shown to be a powerful competitive inhibitor (determined Ki = 4 X 10(-5) M) gave more efficient protection. The partially inactivated enzyme exhibited a Km value similar to that of the unmodified arylsulphatase A, and its Vmax decreased in proportion to the loss of enzymatic activity. The partially modified enzyme did not lose its ability to catalyse hydrolysis of p-nitrocatechol sulphate according to the "anomalous kinetics" exhibited towards this substrate and characteristic for arylsulphatase A. The immunochemical properties of arylsulphatase A either fully or partially inactivated were similar to those of the native enzyme. The results allow to conclude that ferrate reacts with arylsulphatase A in its active site. Thus ferrate seems to be a very sensitive probe for amino acid residues essential for catalytic activity of arylsulphatase A.
Sharp, L; Tilson, L; Whyte, S; O'Ceilleachair, A; Walsh, C; Usher, C; Tappenden, P; Chilcott, J; Staines, A; Barry, M; Comber, H
2012-01-01
Background: Several colorectal cancer-screening tests are available, but it is uncertain which provides the best balance of risks and benefits within a screening programme. We evaluated cost-effectiveness of a population-based screening programme in Ireland based on (i) biennial guaiac-based faecal occult blood testing (gFOBT) at ages 55–74, with reflex faecal immunochemical testing (FIT); (ii) biennial FIT at ages 55–74; and (iii) once-only flexible sigmoidoscopy (FSIG) at age 60. Methods: A state-transition model was used to estimate costs and outcomes for each screening scenario vs no screening. A third party payer perspective was adopted. Probabilistic sensitivity analyses were undertaken. Results: All scenarios would be considered highly cost-effective compared with no screening. The lowest incremental cost-effectiveness ratio (ICER vs no screening €589 per quality-adjusted life-year (QALY) gained) was found for FSIG, followed by FIT (€1696) and gFOBT (€4428); gFOBT was dominated. Compared with FSIG, FIT was associated with greater gains in QALYs and reductions in lifetime cancer incidence and mortality, but was more costly, required considerably more colonoscopies and resulted in more complications. Results were robust to variations in parameter estimates. Conclusion: Population-based screening based on FIT is expected to result in greater health gains than a policy of gFOBT (with reflex FIT) or once-only FSIG, but would require significantly more colonoscopy resources and result in more individuals experiencing adverse effects. Weighing these advantages and disadvantages presents a considerable challenge to policy makers. PMID:22343624
Haug, Ulrike; Knudsen, Amy B; Lansdorp-Vogelaar, Iris; Kuntz, Karen M
2015-06-15
Researchers are actively pursuing the development of a new non-invasive test (NIT) for colorectal cancer (CRC) screening as an alternative to fecal occult blood tests (FOBTs). The majority of pilot studies focus on the detection of invasive CRC rather than precursor lesions (i.e., adenomas). We aimed to explore the relevance of adenoma detection for the viability of an NIT for CRC screening by considering a hypothetical test that does not detect adenomas beyond chance. We used the Simulation Model of Colorectal Cancer (SimCRC) to estimate the effectiveness of CRC screening and the lifetime costs (payers' perspective) for a cohort of US 50-years-old persons to whom CRC screening is offered from age 50-75. We compared annual screening with guaiac and immunochemical FOBTs (with sensitivities up to 70 and 24% for CRC and adenomas, respectively) to annual screening with a hypothetical NIT (sensitivity of 90% for CRC, no detection of adenomas beyond chance, specificity and cost similar to FOBTs). Screening with the NIT was not more effective, but was 29-44% more costly than screening with FOBTs. The findings were robust to varying the screening interval, the NIT's sensitivity for CRC, adherence rates favoring the NIT, and the NIT's unit cost. A comparative modelling approach using a model that assumes a shorter adenoma dwell time (MISCAN-COLON) confirmed the superiority of the immunochemical FOBT over an NIT with no ability to detect adenomas. Information on adenoma detection is crucial to determine whether a new NIT is a viable alternative to FOBTs for CRC screening. Current evidence thus lacks an important piece of information to identify marker candidates that hold real promise and deserve further (large-scale) evaluation. © 2014 UICC.
Clinical and immunologic evaluation of Cedrus deodara pollen: a new allergen from India.
Rawat, A; Singh, A; Singh, A B; Gaur, S N; Kumar, L; Roy, I; Ravindrun, P
2000-07-01
Allergy to pollen from gymnosperms is well documented in the West. However, many allergenic species are native to the Himalayan region of India, and Cedrus deodara (Pinaceae) was selected for allergologic investigation. The objective was to define the allergologic and immunochemical aspects of C. deodara pollen. Pollen antigen from C. deodara (CD) was prepared and characterized by biochemical and biologic assays. Specific IgE binding was determined by means of ELISA and immunoblotting. CD pollen antigen caused marked skin sensitivity in 7.5% of an atopic population. A significantly elevated level of CD-specific IgE antibodies was observed in 65.8% of the skin-positive patients. Immunoblotting showed protein fractions of 37, 44, 58, and 78 kDa with 100% binding with the patients' sera suspected to be due to carbohydrate moieties. Patients from the Himalayan region, where CD occurs naturally, were sensitized more than patients from distant places. The immunochemical characterization revealed multiple protein fractions from low to very high molecular mass (14-126 kDa) mostly in the acidic pI range. CD pollen has been recognized as a new allergen from India for the first time. The role of pollen as a causative agent of respiratory allergic disorders is very well established, as is evident from the recent increase of reports from across the world (1-4). India is blessed with the richest flora on the earth, from alpine tundra to Rajasthan desert. Consequently, it provides considerable variation in the quality and quantity of airborne pollen in different ecogeographic regions of the country (5-8). Although studies on the allergenic properties of airborne pollen from various species have been carried out by several workers in India (9-12), information on allergy to aerial pollen from Himalayan tree species has been completely
Goede, S Lucas; van Roon, Aafke H C; Reijerink, Jacqueline C I Y; van Vuuren, Anneke J; Lansdorp-Vogelaar, Iris; Habbema, J Dik F; Kuipers, Ernst J; van Leerdam, Monique E; van Ballegooijen, Marjolein
2013-05-01
The sensitivity and specificity of a single faecal immunochemical test (FIT) are limited. The performance of FIT screening can be improved by increasing the screening frequency or by providing more than one sample in each screening round. This study aimed to evaluate if two-sample FIT screening is cost-effective compared with one-sample FIT. The MISCAN-colon microsimulation model was used to estimate costs and benefits of strategies with either one or two-sample FIT screening. The FIT cut-off level varied between 50 and 200 ng haemoglobin/ml, and the screening schedule was varied with respect to age range and interval. In addition, different definitions for positivity of the two-sample FIT were considered: at least one positive sample, two positive samples, or the mean of both samples being positive. Within an exemplary screening strategy, biennial FIT from the age of 55-75 years, one-sample FIT provided 76.0-97.0 life-years gained (LYG) per 1000 individuals, at a cost of € 259,000-264,000 (range reflects different FIT cut-off levels). Two-sample FIT screening with at least one sample being positive provided 7.3-12.4 additional LYG compared with one-sample FIT at an extra cost of € 50,000-59,000. However, when all screening intervals and age ranges were considered, intensifying screening with one-sample FIT provided equal or more LYG at lower costs compared with two-sample FIT. If attendance to screening does not differ between strategies it is recommended to increase the number of screening rounds with one-sample FIT screening, before considering increasing the number of FIT samples provided per screening round.
A selective liquid pressurized extraction (SPLE) method was developed as a streamlined sample preparation/cleanup procedure for determining Aroclors and coplanar polychlorinated biphenyls (PCBs) in soil and sediment matrices. The SPLE method was coupled with an enzyme-linked imm...
[Reasearch progress in health economic evaluation of colorectal cancer screening in China].
Huang, Huiyao; Shi, Jufang; Dai, Min
2015-08-01
Burden of colorectal cancer is rising in China. More attention and financial input have been paid to it by central government that colorectal cancer screening program has been carried out recently in many areas in China. Diversity of screening strategies and limited health resources render selecting the best strategy in a population-wide program a challenging task that economy was also required to be considered except safety and efficacy. To provide a reference for the subsequent further economic evaluation, here we reviewed the evidence available on the economic evaluation of colorectal cancer screening in China. Meanwhile, information related to screening strategies, participation and mid-term efficacy of screening, information and results on economic evaluation were extracted and summarized. Three of the four studies finally included evaluated strategies combining immunochemical fecel occult blood test (iFOBT) with high-risk factor questionnaire as initial screening, colonoscopy as diagnostic screening. There was a consensus regarding the efficacy and effectiveness of screening compared to no screening. Whereas the lack and poor comparability between studies, multi-perspective and multi-phase economic evaluation of colorectal cancer screening is needed, relying on current population-based screening program to conduct a comprehensive cost accounting.
21 CFR 866.5560 - Lactic dehydrogenase immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... immunological test system is a device that consists of the reagents used to measure by immunochemical techniques... found in a variety of conditions, including megaloblastic anemia (decrease in the number of mature red blood cells), myocardial infarction (heart disease), and some forms of leukemia (cancer of the blood...
21 CFR 866.5560 - Lactic dehydrogenase immunological test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... immunological test system is a device that consists of the reagents used to measure by immunochemical techniques... found in a variety of conditions, including megaloblastic anemia (decrease in the number of mature red blood cells), myocardial infarction (heart disease), and some forms of leukemia (cancer of the blood...
21 CFR 866.5560 - Lactic dehydrogenase immunological test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... immunological test system is a device that consists of the reagents used to measure by immunochemical techniques... found in a variety of conditions, including megaloblastic anemia (decrease in the number of mature red blood cells), myocardial infarction (heart disease), and some forms of leukemia (cancer of the blood...
21 CFR 866.5560 - Lactic dehydrogenase immunological test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... immunological test system is a device that consists of the reagents used to measure by immunochemical techniques... found in a variety of conditions, including megaloblastic anemia (decrease in the number of mature red blood cells), myocardial infarction (heart disease), and some forms of leukemia (cancer of the blood...
21 CFR 866.5080 - Alpha-1-antichymotrypsin immunological test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Alpha-1-antichymotrypsin immunological test system....5080 Alpha-1-antichymotrypsin immunological test system. (a) Identification. An alpha-1... immunochemical techniques alpha-1-antichymotrypsin (a protein) in serum, other body fluids, and tissues. Alpha-1...
21 CFR 866.5080 - Alpha-1-antichymotrypsin immunological test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Alpha-1-antichymotrypsin immunological test system....5080 Alpha-1-antichymotrypsin immunological test system. (a) Identification. An alpha-1... immunochemical techniques alpha-1-antichymotrypsin (a protein) in serum, other body fluids, and tissues. Alpha-1...
21 CFR 866.5080 - Alpha-1-antichymotrypsin immunological test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Alpha-1-antichymotrypsin immunological test system....5080 Alpha-1-antichymotrypsin immunological test system. (a) Identification. An alpha-1... immunochemical techniques alpha-1-antichymotrypsin (a protein) in serum, other body fluids, and tissues. Alpha-1...
21 CFR 866.5170 - Breast milk immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Breast milk immunological test system. 866.5170... milk immunological test system. (a) Identification. A breast milk immunological test system is a device that consists of the reagents used to measure by immunochemical techniques the breast milk proteins. (b...
21 CFR 866.5170 - Breast milk immunological test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Breast milk immunological test system. 866.5170... milk immunological test system. (a) Identification. A breast milk immunological test system is a device that consists of the reagents used to measure by immunochemical techniques the breast milk proteins. (b...
21 CFR 866.5170 - Breast milk immunological test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Breast milk immunological test system. 866.5170... milk immunological test system. (a) Identification. A breast milk immunological test system is a device that consists of the reagents used to measure by immunochemical techniques the breast milk proteins. (b...
21 CFR 866.5170 - Breast milk immunological test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Breast milk immunological test system. 866.5170... milk immunological test system. (a) Identification. A breast milk immunological test system is a device that consists of the reagents used to measure by immunochemical techniques the breast milk proteins. (b...
Immunochemical Investigations of Cell Surface Antigens of Anaerobic Bacteria
1984-10-15
portion is linked to a carbohydrate core, which contains two unusual sugars (2- keto -3-deoxyoctonate and a heptose), as well as glucose, galactose, and...present in human intestinal contents. However, placing rats on a diet of lean ground beef for a two-week period resulted in alteration of the cecal
21 CFR 866.5785 - Anti-Saccharomyces cerevisiae (S. cerevisiae) antibody (ASCA) test systems.
Code of Federal Regulations, 2011 CFR
2011-04-01
... an in vitro diagnostic device that consists of the reagents used to measure, by immunochemical techniques, antibodies to S. cerevisiae (baker's or brewer's yeast) in human serum or plasma. Detection of S. cerevisiae antibodies may aid in the diagnosis of Crohn's disease. (b) Classification. Class II (special...
Quantification of protein carbonylation.
Wehr, Nancy B; Levine, Rodney L
2013-01-01
Protein carbonylation is the most commonly used measure of oxidative modification of proteins. It is most often measured spectrophotometrically or immunochemically by derivatizing proteins with the classical carbonyl reagent 2,4 dinitrophenylhydrazine (DNPH). We present protocols for the derivatization and quantification of protein carbonylation with these two methods, including a newly described dot blot with greatly increased sensitivity.
The HERB-LV has developed several immunoassay methods for environmental and human exposure studies. Immunoassays to detect low levels (<10 ng/mL) chlorpyrifos in track-in dirt and house dust have been developed for indoor exposure surveys. An immunoassay for the urinary metabol...
A review of promising new immunoassay technology for monitoring forest herbicides
Charles K. McMahon
1993-01-01
Rising costs of classical instrumental methods of chemical analysis coupled with an increasing need for environmental monitoring has lead to the development of highly sensitive, low-cost immunochemical methods of analysis for the detection of environmental contaminants. These methods known simply as immunoassays are chemical assays which use antibodies as reagents. A...
21 CFR 866.5590 - Lipoprotein X immunolog-ical test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Lipoprotein X immunolog-ical test system. 866.5590... Lipoprotein X immunolog-ical test system. (a) Identification. A lipoprotein X immunological test system is a device that consists of the reagents used to measure by immunochemical techniques lipoprotein X (a high...
21 CFR 866.5590 - Lipoprotein X immunolog-ical test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Lipoprotein X immunolog-ical test system. 866.5590... Lipoprotein X immunolog-ical test system. (a) Identification. A lipoprotein X immunological test system is a device that consists of the reagents used to measure by immunochemical techniques lipoprotein X (a high...
21 CFR 866.5590 - Lipoprotein X immunolog-ical test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Lipoprotein X immunolog-ical test system. 866.5590... Lipoprotein X immunolog-ical test system. (a) Identification. A lipoprotein X immunological test system is a device that consists of the reagents used to measure by immunochemical techniques lipoprotein X (a high...
21 CFR 866.5590 - Lipoprotein X immunolog-ical test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Lipoprotein X immunolog-ical test system. 866.5590... Lipoprotein X immunolog-ical test system. (a) Identification. A lipoprotein X immunological test system is a device that consists of the reagents used to measure by immunochemical techniques lipoprotein X (a high...
21 CFR 866.5590 - Lipoprotein X immunolog-ical test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Lipoprotein X immunolog-ical test system. 866.5590... Lipoprotein X immunolog-ical test system. (a) Identification. A lipoprotein X immunological test system is a device that consists of the reagents used to measure by immunochemical techniques lipoprotein X (a high...
Dry immunochemical sensor for the detection of PETN vapor
NASA Astrophysics Data System (ADS)
Lukens, Herbert Richard
1992-05-01
Giaever (1973) showed that an indium semi-mirror coated with a monolayer of a substance would undergo reduced optical reflectance after incubation with a solution of the substance's antibody. He was able to see the effect with the naked eye. Lukens and Williams (1977) reversed the process by first attaching the target substance's antibody to the semi-mirror, after which the device would show a decline in optical density when exposed to a solution of the target substance. Lukens and Williams (1982) subsequently found that the device could also be used as an immunochemical film badge (IFB) to detect an airborne target substance. Early efforts to develop the IFB for the detection of airborne substances were plagued by such a high degree of performance variability that there were doubts in some quarters that an airborne target substance could bind to its antibody until Lukens (1990) demonstrated such binding in experiments with radiolabeled cocaine and morphine. Recently improved semi-mirrors and densitometry have been obtained and have led to improved performance of IFB's. As shown in this paper, IFB's can now be constructed that detect PETN vapor in a few seconds.
Determination of N epsilon-(carboxymethyl)lysine in foods and related systems.
Ames, Jennifer M
2008-04-01
The sensitive and specific determination of advanced glycation end products (AGEs) is of considerable interest because these compounds have been associated with pro-oxidative and proinflammatory effects in vivo. AGEs form when carbonyl compounds, such as glucose and its oxidation products, glyoxal and methylglyoxal, react with the epsilon-amino group of lysine and the guanidino group of arginine to give structures including N epsilon-(carboxymethyl)lysine (CML), N epsilon-(carboxyethyl)lysine, and hydroimidazolones. CML is frequently used as a marker for AGEs in general. It exists in both the free or peptide-bound forms. Analysis of CML involves its extraction from the food (including protein hydrolysis to release any peptide-bound adduct) and determination by immunochemical or instrumental means. Various factors must be considered at each step of the analysis. Extraction, hydrolysis, and sample clean-up are all less straight forward for food samples, compared to plasma and tissue. The immunochemical and instrumental methods all have their advantages and disadvantages, and no perfect method exists. Currently, different procedures are being used in different laboratories, and there is an urgent need to compare, improve, and validate methods.
Faecal occult blood screening for colorectal cancer in Serbia: a pilot study.
Scepanovic, Milena; Jovanovic, Olivera; Keber, Dusan; Jovanovic, Ivan; Miljus, Dragan; Nikolic, Goran; Kovacevic, Bojan; Pavlovic, Aleksandra; Dugalic, Predrag; Nagorni, Aleksandar; Grgov, Sasa; Knezevic, Slavko; Milenkovic, Predrag; Perisic, Nenad; Faivre, Jean
2017-05-01
Colorectal cancer (CRC) is becoming a major public health problem in the Republic of Serbia. Organized mass screening has been shown to decrease CRC mortality and even its incidence. The aim of this study was to assess the acceptability of a faecal immunochemical test for haemoglobin proposed by primary care physicians. From August to November 2013, a pilot study for CRC screening was organized in individuals aged 50 to 74 years. The study included 50 primary healthcare centres from all 25 administrative regions of Serbia. A qualitative immunochromatographic faecal immunochemical test for human haemoglobin detection was used. Overall, 50 894 individuals were invited. The participation rate was 67.8 and 3.4% of the tests were positive. Among individuals with a positive test, 69.7% agreed to undergo colonoscopy. The positive predictive value was 27.1% for adenoma and 14.6% for carcinoma. This was the first CRC screening project encompassing approximately one-third of primary healthcare facilities in all regions across the country. It showed a good response of the target population and satisfactory cooperation of the healthcare professionals involved.
Greuter, Marjolein J E; de Klerk, Clasine M; Meijer, Gerrit A; Dekker, Evelien; Coupé, Veerle M H
2017-10-17
Population-based screening to prevent colorectal cancer (CRC) death is effective, but the effectiveness of postpolypectomy surveillance is unclear. To evaluate the additional benefit in terms of cost-effectiveness of colonoscopy surveillance in a screening setting. Microsimulation using the ASCCA (Adenoma and Serrated pathway to Colorectal CAncer) model. Dutch CRC screening program and published literature. Asymptomatic persons aged 55 to 75 years without a prior CRC diagnosis. Lifetime. Health care payer. Fecal immunochemical test (FIT) screening with colonoscopy surveillance performed according to the Dutch guideline was simulated. The comparator was no screening or surveillance. FIT screening without colonoscopy surveillance and the effect of extending surveillance intervals were also evaluated. CRC burden, colonoscopy demand, life-years, and costs. FIT screening without surveillance reduced CRC mortality by 50.4% compared with no screening or surveillance. Adding surveillance to FIT screening reduced mortality by an additional 1.7% to 52.1% but increased lifetime colonoscopy demand by 62% (from 335 to 543 colonoscopies per 1000 persons) at an additional cost of €68 000, for an increase of 0.9 life-year. Extending the surveillance intervals to 5 years reduced CRC mortality by 51.8% and increased colonoscopy demand by 42.7% compared with FIT screening without surveillance. In an incremental analysis, incremental cost-effectiveness ratios (ICERs) for screening plus surveillance exceeded the Dutch willingness-to-pay threshold of €36 602 per life-year gained. When using a parameter set representing low colorectal lesion prevalence or when colonoscopy costs were halved or colorectal lesion incidence was doubled, screening plus surveillance became cost-effective compared with screening without surveillance. Limited data on FIT performance and background CRC risk in the surveillance population. Adding surveillance to FIT screening is not cost-effective based on the Dutch ICER threshold and substantially increases colonoscopy demand. Extending surveillance intervals to 5 years would decrease colonoscopy demand without substantial loss of effectiveness. Alpe d'HuZes, Dutch Cancer Society, and Stand Up To Cancer.
Electrochemical detection of fluoroquinolone antibiotics in milk using a magneto immunosensor.
Pinacho, Daniel G; Sánchez-Baeza, Francisco; Pividori, María-Isabel; Marco, María-Pilar
2014-08-28
An amperometric magneto-immunosensor (AMIS) for the detection of residues of fluoroquinolone antibiotics in milk samples is described for the first time. The immunosensor presented combines magnetic beads biomodified with an antibody with a broad recognition profile of fluoroquinolones, a haptenized enzyme and a magnetic graphite-epoxy composite (m-GEC) electrode. After the immunochemical reaction with specific enzyme tracer, the antibody biomodified magnetic beads are easily captured by an electrode made of graphite-epoxy composite containing a magnet, which also acts as transducer for the electrochemical detection. In spite of the complexity of milk, the use of magnetic beads allows elimination of potential interferences caused by the matrix components; hence the AMIS could perform quantitative measurements, directly in these samples, without any additional sample cleanup or extraction step. The immunosensor is able to detect up to seven different fluoroquinolones far below the MRLs defined by the UE for milk; for example ciprofloxacin is detected directly in milk with an IC50 of 0.74 µg/L and a LOD of 0.009 µg/L. This strategy offers great promise for rapid, simple, cost-effective, and on-site analysis fluoroquinolones in complex samples.
Electrochemical Detection of Fluoroquinolone Antibiotics in Milk Using a Magneto Immunosensor
Pinacho, Daniel G.; Sánchez-Baeza, Francisco; Pividori, María-Isabel; Marco, María-Pilar
2014-01-01
An amperometric magneto-immunosensor (AMIS) for the detection of residues of fluoroquinolone antibiotics in milk samples is described for the first time. The immunosensor presented combines magnetic beads biomodified with an antibody with a broad recognition profile of fluoroquinolones, a haptenized enzyme and a magnetic graphite–epoxy composite (m-GEC) electrode. After the immunochemical reaction with specific enzyme tracer, the antibody biomodified magnetic beads are easily captured by an electrode made of graphite-epoxy composite containing a magnet, which also acts as transducer for the electrochemical detection. In spite of the complexity of milk, the use of magnetic beads allows elimination of potential interferences caused by the matrix components; hence the AMIS could perform quantitative measurements, directly in these samples, without any additional sample cleanup or extraction step. The immunosensor is able to detect up to seven different fluoroquinolones far below the MRLs defined by the UE for milk; for example ciprofloxacin is detected directly in milk with an IC50 of 0.74 μg/L and a LOD of 0.009 μg/L. This strategy offers great promise for rapid, simple, cost-effective, and on-site analysis fluoroquinolones in complex samples. PMID:25171120
Whitcomb, Tiffany; Sakurai, Keisuke; Brown, Bruce M.; Young, Joyce E.; Sheflin, Lowell; Dlugos, Cynthia; Craft, Cheryl M.; Kefalov, Vladimir J.
2010-01-01
Purpose. Photoreceptor rhodopsin kinase (Rk, G protein–dependent receptor kinase 1 [Grk1]) phosphorylates light-activated opsins and channels them into an inactive complex with visual arrestins. Grk1 deficiency leads to human retinopathy and heightened susceptibility to light-induced photoreceptor cell death in the mouse. The goal of this study was to determine whether excess Grk1 activity is protective against photoreceptor cell death. Methods. Grk1-overexpressing transgenic mice (Grk1+) were generated by using a bacterial artificial chromosome (BAC) construct containing mouse Grk1, along with its flanking sequences. Quantitative reverse transcription-PCR, immunoblot analysis, immunostaining, and activity assays were combined with electrophysiology and morphometric analysis, to evaluate Grk1 overexpression and its effect on physiologic and morphologic retinal integrity. Morphometry and nucleosome release assays measured differences in resistance to photoreceptor cell loss between control and transgenic mice exposed to intense light. Results. Compared with control animals, the Grk1+ transgenic line had approximately a threefold increase in Grk1 transcript and immunoreactive protein. Phosphorylated opsin immunochemical staining and in vitro phosphorylation assays confirmed proportionately higher Grk1 enzyme activity. Grk1+ mice retained normal rod function, normal retinal appearance, and lacked evidence of spontaneous apoptosis when reared in cyclic light. In intense light, Grk1+ mice showed photoreceptor damage, and their susceptibility was more pronounced than that of control mice with prolonged exposure times. Conclusions. Enhancing visual pigment deactivation does not appear to protect against apoptosis; however, excess flow of opsin into the deactivation pathway may actually increase susceptibility to stress-induced cell death similar to some forms of retinal degeneration. PMID:19834036
Bosch, Linda J W; Oort, Frank A; Neerincx, Maarten; Khalid-de Bakker, Carolina A J; Terhaar sive Droste, Jochim S; Melotte, Veerle; Jonkers, Daisy M A E; Masclee, Ad A M; Mongera, Sandra; Grooteclaes, Madeleine; Louwagie, Joost; van Criekinge, Wim; Coupé, Veerle M H; Mulder, Chris J; van Engeland, Manon; Carvalho, Beatriz; Meijer, Gerrit A
2012-03-01
Using a bioinformatics-based strategy, we set out to identify hypermethylated genes that could serve as biomarkers for early detection of colorectal cancer (CRC) in stool. In addition, the complementary value to a Fecal Immunochemical Test (FIT) was evaluated. Candidate genes were selected by applying cluster alignment and computational analysis of promoter regions to microarray-expression data of colorectal adenomas and carcinomas. DNA methylation was measured by quantitative methylation-specific PCR on 34 normal colon mucosa, 71 advanced adenoma, and 64 CRC tissues. The performance as biomarker was tested in whole stool samples from in total 193 subjects, including 19 with advanced adenoma and 66 with CRC. For a large proportion of these series, methylation data for GATA4 and OSMR were available for comparison. The complementary value to FIT was measured in stool subsamples from 92 subjects including 44 with advanced adenoma or CRC. Phosphatase and Actin Regulator 3 (PHACTR3) was identified as a novel hypermethylated gene showing more than 70-fold increased DNA methylation levels in advanced neoplasia compared with normal colon mucosa. In a stool training set, PHACTR3 methylation showed a sensitivity of 55% (95% CI: 33-75) for CRC and a specificity of 95% (95% CI: 87-98). In a stool validation set, sensitivity reached 66% (95% CI: 50-79) for CRC and 32% (95% CI: 14-57) for advanced adenomas at a specificity of 100% (95% CI: 86-100). Adding PHACTR3 methylation to FIT increased sensitivity for CRC up to 15%. PHACTR3 is a new hypermethylated gene in CRC with a good performance in stool DNA testing and has complementary value to FIT.
Idigoras, I; Arrospide, A; Portillo, I; Arana-Arri, E; Martínez-Indart, L; Mar, J; de Koning, H J; Lastra, R; Soto-Gordoa, M; van der Meulen, M; Lansdorp-Vogelaar, I
2017-08-01
The population-based Basque Colorectal Cancer (CRC) Screening Programme started in 2009 with a biennial immunochemical quantitative test (FIT) biennial and colonoscopy under sedation in positive cases. The population target of 586,700 residents was from 50 to 69 years old and the total coverage was reached at the beginning of 2014. The aim of our study was to determine possible scenarios in terms of incidence, mortality and reduction of Life-years-Lost (L-y-L) in the medium and long term of CRC. Invitations were sent out by the Programme from 2009 to 2014, with combined organizational strategies. Simulation was done by MISCAN-colon (Microsimulation Screening Analysis) over 30 years comparing the results of screening vs no-screening, taking the population-based Cancer Registry into account. Lifetime population and real data from the Programme were used from 2008 to 2012. The model was run differentially for men and women. 924,416 invitations were sent out from 2009 to 2014. The average participation rate was 68.4%, CRC detection rate was 3.4% and the Advanced Adenoma detection rate was 24.0‰, with differences observed in sex and age. Future scenarios showed a higher decrease of incidence (17.2% vs 14.7%), mortality (28.1% vs 22.4%) and L-y-L (22.6% vs 18.4%) in men than women in 2030. The Basque Country CRC Programme results are aligned to its strategy and comparable to other programmes. MISCAN model was found to be a useful tool to predict the benefits of the programme in the future. The effectiveness of the Programme has not been formally established as case control studies are required to determine long term benefits from the screening strategy.
Ross Friedman, Cynthia; Ross, Bradford N; Martens, Garnet D
2013-02-01
Dwarf mistletoes, genus Arceuthobium (Santalaceae), are parasitic angiosperms that spread their seeds by an explosive process. As gentle heating triggers discharge in the lab, we wondered if thermogenesis (endogenous heat production) is associated with dispersal. Thermogenesis occurs in many plants and is enabled by mitochondrial alternative oxidase (AOX) activity. The purpose of this study was to probe Arceuthobium americanum fruit (including seed tissues) collected over a 10-week period with an anti-AOX antibody/gold-labeled secondary antibody to determine if AOX could be localized in situ, and if so, quantitatively assess whether label distribution changed during development; immunochemical results were evaluated with Western blotting. No label could be detected in the mitochondria of any fruit or seed tissue, but was observed in fruit exocarp plastids of samples collected in the last 2 weeks of study; plastids collected in week 10 had significantly more label than week 9 (p = 0.002). Western blotting of whole fruit and mitochondrial proteins revealed a signal at 30-36 kD, suggestive of AOX, while blots of whole fruit (but not mitochondrial fraction) proteins showed a second band at 40-45 kD, in agreement with plastid terminal oxidases (PTOXs). AOX enzymes are likely present in the A. americanum fruit, even though they were not labeled in mitochondria. The results strongly indicate that the anti-AOX antibody was labeling PTOX in plastids, probably at a C-terminal region conserved in both enzymes. PTOX in plastids may be involved in fruit ripening, although a role for PTOX in thermogenesis cannot be eliminated.
Tyrosine-Nitrated Proteins: Proteomic and Bioanalytical Aspects.
Batthyány, Carlos; Bartesaghi, Silvina; Mastrogiovanni, Mauricio; Lima, Analía; Demicheli, Verónica; Radi, Rafael
2017-03-01
"Nitroproteomic" is under active development, as 3-nitrotyrosine in proteins constitutes a footprint left by the reactions of nitric oxide-derived oxidants that are usually associated to oxidative stress conditions. Moreover, protein tyrosine nitration can cause structural and functional changes, which may be of pathophysiological relevance for human disease conditions. Biological protein tyrosine nitration is a free radical process involving the intermediacy of tyrosyl radicals; in spite of being a nonenzymatic process, nitration is selectively directed toward a limited subset of tyrosine residues. Precise identification and quantitation of 3-nitrotyrosine in proteins has represented a "tour de force" for researchers. Recent Advances: A small number of proteins are preferential targets of nitration (usually less than 100 proteins per proteome), contrasting with the large number of proteins modified by other post-translational modifications such as phosphorylation, acetylation, and, notably, S-nitrosation. Proteomic approaches have revealed key features of tyrosine nitration both in vivo and in vitro, including selectivity, site specificity, and effects in protein structure and function. Identification of 3-nitrotyrosine-containing proteins and mapping nitrated residues is challenging, due to low abundance of this oxidative modification in biological samples and its unfriendly behavior in mass spectrometry (MS)-based technologies, that is, MALDI, electrospray ionization, and collision-induced dissociation. The use of (i) classical two-dimensional electrophoresis with immunochemical detection of nitrated proteins followed by protein ID by regular MS/MS in combination with (ii) immuno-enrichment of tyrosine-nitrated peptides and (iii) identification of nitrated peptides by a MIDAS™ experiment is arising as a potent methodology to unambiguously map and quantitate tyrosine-nitrated proteins in vivo. Antioxid. Redox Signal. 26, 313-328.
Nucleophosmin/B23 is a proliferate shuttle protein associated with nuclear matrix.
Yun, Jing-Ping; Chew, Eng Ching; Liew, Choong-Tsek; Chan, John Y H; Jin, Mei-Lin; Ding, Ming-Xiao; Fai, Yam Hin; Li, H K Richard; Liang, Xiao-Man; Wu, Qiu-Liang
2003-12-15
It has become obvious that a better understanding and potential elucidation of the nucleolar phosphoprotein B23 involving in functional interrelationship between nuclear organization and gene expression. In present study, protein B23 expression were investigated in the regenerative hepatocytes at different periods (at days 0, 1, 2, 3, 4, 7) during liver regeneration after partial hepatectomy on the rats with immunohistochemistry and Western blot analysis. Another experiment was done with immunolabeling methods and two-dimensional (2-D) gel electrophoresis for identification of B23 in the regenerating hepatocytes and HepG2 cells (hepatoblastoma cell line) after sequential extraction with detergents, nuclease, and salt. The results showed that its expression in the hepatocytes had a locative move and quantitative change during the process of liver regeneration post-operation. Its immunochemical localization in the hepatocytes during the process showed that it moved from nucleoli of the hepatocytes in the stationary stage to nucleoplasm, cytoplasm, mitotic spindles, and mitotic chromosomes of the hepatocytes in the regenerating livers. It was quantitatively increased progressively to peak level at day 3 post-operation and declined gradually to normal level at day 7. It was detected in nuclear matrix protein (NMP) composition extracted from the regenerating hepatocytes and HepG2 cells and identified with isoelectric point (pI) value of 5.1 and molecular weight of 40 kDa. These results indicated that B23 was a proliferate shuttle protein involving in cell cycle and cell proliferation associated with nuclear matrix. Copyright 2003 Wiley-Liss, Inc.
Moss, Sue; Mathews, Christopher; Day, T J; Smith, Steve; Seaman, Helen E; Snowball, Julia; Halloran, Stephen P
2017-09-01
The National Health Service Bowel Cancer Screening Programme (BCSP) in England uses a guaiac-based faecal occult blood test (gFOBt). A quantitative faecal immunochemical test (FIT) for haemoglobin (Hb) has many advantages, including being specific for human blood, detecting Hb at a much lower concentration with a single faecal sample and improved uptake. In 2014, a large comparative pilot study was performed within BCSP to establish the acceptability and diagnostic performance of FIT. Over a 6-month period, 40 930 (1 in 28) subjects were sent a FIT (OC-SENSOR) instead of a gFOBt. A bespoke FIT package was used to mail FIT sampling devices to and from FIT subjects. All participants positive with either gFOBt or FIT (cut-off 20 µg Hb/g faeces) were referred for follow-up. Subgroup analysis included cut-off concentrations, age, sex, screening history and deprivation quintile. While overall uptake increased by over 7 percentage points with FIT (66.4% vs 59.3%, OR 1.35, 95% CI 1.33 to 1.38), uptake by previous non-responders almost doubled (FIT 23.9% vs gFOBt 12.5%, OR 2.20, 95% CI 2.10 to 2.29). The increase in overall uptake was significantly higher in men than women and was observed across all deprivation quintiles. With the conventional 20 µg/g cut-off, FIT positivity was 7.8% and ranged from 5.7% in 59-64-year-old women to 11.1% in 70-75-year-old men. Cancer detection increased twofold and that for advanced adenomas nearly fivefold. Detection rates remained higher with FIT for advanced adenomas, even at 180 µg Hb/g. Markedly improved participation rates were achieved in a mature gFOBt-based national screening programme and disparities between men and women were reduced. High positivity rates, particularly in men and previous non-respondents, challenge the available colonoscopy resource, but improvements in neoplasia detection are still achievable within this limited resource. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Heightened sense for sensing: recent advances in pathogen immunoassay sensing platforms.
Fischer, Nicholas O; Tarasow, Theodore M; Tok, Jeffrey B-H
2007-03-01
Rapid and efficient sensors are essential for effective defense against the emerging threat of bioterrorism and biological warfare. This review article describes several recent immunosensing advances that are relevant to biothreat detection. These highly diverse examples are intended to demonstrate the breadth of these immunochemical sensing systems and platforms while highlighting those technologies that are suitable for pathogen detection.
[A comparative immunochemical analysis of allergoids and allergens].
Fradkin, V A; Tsvetkov, N V; Diakiv, V V; Lavrenchik, E I
1992-01-01
In comparison with allergens having protein fragments with a molecular weight not exceeding 110 kD, allergoids have been found to consist of larger fragments with a molecular weight of 10-150 kD. Allergoids have less charged components than initial allergens and less antigenic components. Allergoids retain their capacity for stimulating the production of antibodies, specific to all antigenic components.
USDA-ARS?s Scientific Manuscript database
Prions, or infectious proteins, cause a class of uniformly fatal neurodegenerative diseases. Prions are composed solely of an aberrantly folded isoform(PrPSc)of a normal cellular protein (PrPC). Shared sequence identity of PrPSc with PrPC has limited the detection sensitivity of immunochemical assay...
Pifano, F; Aguilar, I; Giron, M E; Gamboa, N; Rodriguez-Acosta, A
1993-01-01
The inactivation of local and general effects of the Mapanare (Bothrops lanceolatus) venom by Opossum's (Didelphis marsupialis) serum fractions was tested using an in vivo assay and an in vitro preincubation experiment. A serum fraction of the Opossum serum has been obtained by immunochemical purification. It is only present in opossum's protective opossum serum fraction (F-0.1).
Coronado, Gloria D; Sanchez, Jen; Petrik, Amanda; Kapka, Tanya; DeVoe, Jen; Green, Beverly
2014-03-01
Some patients face difficulty understanding instructions for completing the fecal immunochemical test (FIT), a self-administered test to screen for colorectal cancer. We sought to develop and test low-literacy instructions for completing the FIT. Working in partnership with a Latino-serving Federally Qualified Health Center (FQHC) in the Portland Metro area, we developed and tested low-literacy instructions for completing the FIT; the instructions contained seven words (mail within 3 days; Devolver dentro de 3 dias). We conducted focus groups of Spanish-speaking patients on the advisory council of our partnering FQHC organization, and we gathered feedback from the project's advisory board members and clinic staff. We mailed a FIT kit to each patient, along with either (a) instructions written in English and Spanish, consisting of 415 words; or (b) low-literacy "wordless" instructions. We asked patients to complete the test before providing feedback. Our qualitative assessment showed that the wordless instructions were preferred over instructions consisting of words. Wordless instructions might aid efforts to raise the rates of colorectal cancer screening among low-literacy and non-English-speaking populations.
Adherence to colorectal cancer screening: four rounds of faecal immunochemical test-based screening.
van der Vlugt, Manon; Grobbee, Esmée J; Bossuyt, Patrick Mm; Bongers, Evelien; Spijker, Wolfert; Kuipers, Ernst J; Lansdorp-Vogelaar, Iris; Essink-Bot, Marie-Louise; Spaander, Manon C W; Dekker, Evelien
2017-01-03
The effectiveness of faecal immunochemical test (FIT)-based screening programs is highly dependent on consistent participation over multiple rounds. We evaluated adherence to FIT screening over four rounds and aimed to identify determinants of participation behaviour. A total of 23 339 randomly selected asymptomatic persons aged 50-74 years were invited for biennial FIT-based colorectal cancer screening between 2006 and 2014. All were invited for every consecutive round, except for those who had moved out of the area, passed the upper age limit, or had tested positive in a previous screening round. A reminder letter was sent to non-responders. We calculated participation rates per round, response rates to a reminder letter, and differences in participation between subgroups defined by age, sex, and socioeconomic status (SES). Over the four rounds, participation rates increased significantly, from 60% (95% CI 60-61), 60% (95% CI 59-60), 62% (95% CI 61-63) to 63% (95% CI 62-64; P for trend<0.001) with significantly higher participation rates in women in all rounds (P<0.001). Of the 17 312 invitees eligible for at least two rounds of FIT screening, 12 455 (72%) participated at least once, whereas 4857 (28%) never participated; 8271 (48%) attended all rounds when eligible. Consistent participation was associated with older age, female sex, and higher SES. Offering a reminder letter after the initial invite in the first round increased uptake with 12%; in subsequent screening rounds this resulted in an additional uptake of up to 10%. In four rounds of a pilot biennial FIT-screening program, we observed a consistently high and increasing participation rate, whereas sending reminders remain effective. The substantial proportion of inconsistent participants suggests the existence of incidental barriers to participation, which, if possible, should be identified and removed.
van der Meulen, Miriam P; Lansdorp-Vogelaar, Iris; van Heijningen, Else-Mariëtte B; Kuipers, Ernst J; van Ballegooijen, Marjolein
2016-06-01
If some adenomas do not bleed over several years, they will cause systematic false-negative fecal immunochemical test (FIT) results. The long-term effectiveness of FIT screening has been estimated without accounting for such systematic false-negativity. There are now data with which to evaluate this issue. The authors developed one microsimulation model (MISCAN [MIcrosimulation SCreening ANalysis]-Colon) without systematic false-negative FIT results and one model that allowed a percentage of adenomas to be systematically missed in successive FIT screening rounds. Both variants were adjusted to reproduce the first-round findings of the Dutch CORERO FIT screening trial. The authors then compared simulated detection rates in the second screening round with those observed, and adjusted the simulated percentage of systematically missed adenomas to those data. Finally, the authors calculated the impact of systematic false-negative FIT results on the effectiveness of repeated FIT screening. The model without systematic false-negativity simulated higher detection rates in the second screening round than observed. These observed rates could be reproduced when assuming that FIT systematically missed 26% of advanced and 73% of nonadvanced adenomas. To reduce the false-positive rate in the second round to the observed level, the authors also had to assume that 30% of false-positive findings were systematically false-positive. Systematic false-negative FIT testing limits the long-term reduction of biennial FIT screening in the incidence of colorectal cancer (35.6% vs 40.9%) and its mortality (55.2% vs 59.0%) in participants. The results of the current study provide convincing evidence based on the combination of real-life and modeling data that a percentage of adenomas are systematically missed by repeat FIT screening. This impairs the efficacy of FIT screening. Cancer 2016;122:1680-8. © 2016 American Cancer Society. © 2016 American Cancer Society.
Juul, Jakob Søgaard; Bro, Flemming; Hornung, Nete; Andersen, Berit Sanne; Laurberg, Søren; Olesen, Frede; Vedsted, Peter
2016-07-11
Colorectal cancer is a common malignancy and a leading cause of cancer-related death. Half of patients with colorectal cancer initially present with non-specific or vague symptoms. In the need for a safe low-cost test, the immunochemical faecal occult blood test (iFOBT) may be part of the evaluation of such patients in primary care. Currently, Danish general practitioners have limited access to this test. The aim of this article is to describe a study that will assess the uptake and clinical use of iFOBT in general practice. Furthermore, it will investigate the diagnostic value and the clinical implications of using iFOBT in general practice on patients presenting with non-alarm symptoms of colorectal cancer. The study uses a cluster-randomised stepped-wedge design and is conducted in the Central Denmark Region among 836 GPs in 381 general practices. The municipalities of the Region and their appertaining general practitioners will be included sequentially in the study during the first 7 months of the 1-year study period. The following intervention has been developed for the study: a mandatory intervention providing all general practitioners with a starting package of 10 iFOBTs, a clinical instruction on iFOBT use in general practice and online information material from the date of inclusion, and an optional intervention consisting of a continuous medical education on colorectal cancer diagnostics and use of iFOBT. This study is among the first and largest trials to investigate the diagnostic use and the clinical value of iFOBT on patients presenting with non-alarm symptoms of colorectal cancer. The findings will be of national and international importance for the future planning of colorectal cancer diagnostics, particularly for 'low-risk-but-not-no-risk' patients with non-alarm symptoms of colorectal cancer. A Trial of the Implementation of iFOBT in General Practice NCT02308384 . Date of registration: 26 November 2014.
Efstratiou, Androulla; Engler, Kathryn H.; Dawes, Charlotte S.; Sesardic, Dorothea
1998-01-01
We have compared molecular, immunochemical, and cytotoxic assays for the detection of diphtheria toxin from 55 isolates of Corynebacterium diphtheriae and Corynebacterium ulcerans originally isolated in five different countries. The suitabilities and accuracies of these assays for the laboratory diagnosis of diphtheria were compared and evaluated against the “gold standard” in vivo methods. The in vivo and Vero cell cytotoxicity assays were accurate in their abilities to detect diphtheria toxin but were time-consuming; however, the cytotoxicity assay is a suitable in vitro alternative to the in vivo virulence test. There was complete concordance between all the phenotypic methods. Genotypic tests based upon PCR were rapid; however, PCR must be used with caution because some isolates of C. diphtheriae possessed toxin genes but failed to express a biologically active toxin. Therefore, phenotypic confirmation of toxigenicity for the microbiological diagnosis of diphtheria is recommended. PMID:9774560
Efstratiou, A; Engler, K H; Dawes, C S; Sesardic, D
1998-11-01
We have compared molecular, immunochemical, and cytotoxic assays for the detection of diphtheria toxin from 55 isolates of Corynebacterium diphtheriae and Corynebacterium ulcerans originally isolated in five different countries. The suitabilities and accuracies of these assays for the laboratory diagnosis of diphtheria were compared and evaluated against the "gold standard" in vivo methods. The in vivo and Vero cell cytotoxicity assays were accurate in their abilities to detect diphtheria toxin but were time-consuming; however, the cytotoxicity assay is a suitable in vitro alternative to the in vivo virulence test. There was complete concordance between all the phenotypic methods. Genotypic tests based upon PCR were rapid; however, PCR must be used with caution because some isolates of C. diphtheriae possessed toxin genes but failed to express a biologically active toxin. Therefore, phenotypic confirmation of toxigenicity for the microbiological diagnosis of diphtheria is recommended.
Effects of processing on the recovery of food allergens from a model dark chocolate matrix.
Khuda, Sefat E; Jackson, Lauren S; Fu, Tong-Jen; Williams, Kristina M
2015-02-01
To alleviate the risk to allergic consumers, it is crucial to improve factors affecting the detection of food allergens in processed chocolate products. This study evaluated processing effects on (1) recovery of peanut, egg, and milk allergens using five different extraction buffers, and (2) identification of specific allergenic proteins from extracts of incurred chocolate using allergen-specific antibodies and human allergic sera. Immunochemical staining with polyclonal antibodies showed that the addition of detergent or reducing agent improved extraction efficiency of peanut proteins, but not of egg and milk proteins. Tempering decreased antibody binding regardless of extractant. Detection of IgE-reactive peanut, egg, and milk allergens was differentially affected by tempering and extractant. Detection problems associated with matrix and processing effects may be overcome by the choice of extraction buffer and detecting antibody. Published by Elsevier Ltd.
[The isolation and evaluation of Aspergillus fumigatus antigens].
Lirio, V de S; de Assis, C M; Cano, M I; Lacaz, C da S
1992-01-01
Antigens from three strains of Aspergillus fumigatus (354, 356, and JIG) and an antiserum against the mixing of these antigens have been produced, and evaluated immunochemically. The antigens were obtained through a modified Coleman & Kaufman technique (culture filtrate concentrated by acetone). Analysis by the immunodiffusion test (ID) against homologous serum has yielded 100% sensitivity (with the studied sera). Concerning heterologous sera we found reactivity with a serum of a patient of candidiasis and another with histoplasmosis. The same result was obtained with a reference antigen in immunodiffusion, showing similar standards of response. Titration of the antiserum by ID and counterimmunoelectrophoresis showed a title of 1:32, and by complement fixation (micro-technique) a title of 1:128. Using immunoelectrophoresis (IEF), the produced antiserum yielded 8 lines of precipitation (5 in the anodic pole and 3 in the cathodic one). In SDS-PAGE at 12.5% the antigen has presented a rather complex electrophoretic profile (26 proteic subunits with a molecular weight ranging from 18 a > 100 kDa). Immunogenicity of the antigen was observed in all fractions of SDS-PAGE when the immunoblotting against the antiserum was carried out.
Hunter, E. F.; Smith, J. F.; Lewis, J. S.; McGrew, B. E.; Schmale, J. D.
1972-01-01
Fluorescein-labeled anti-human globulins were examined to determine the need for standardization of conjugates used in the fluorescent treponemal antibody-absorption (FTA-ABS) test. Twenty-one of 33 conjugates submitted by commercial manufacturers to the Reagents Control Activity, Venereal Disease Research Laboratory, for evaluation in the FTA-ABS test were available for study. Conjugates, after evaluation in FTA-ABS performance tests, were examined by immunoelectrophoresis, by titration against immunoglobulins G and M (IgG, IgM) with FTA-ABS techniques, and by the biuret protein and fluorescein diacetate methods for determining fluorescein to protein (F/P) ratios. The conjugates were predominately anti-IgG globulin with anti-light-chain activity. Differences were noted in the ability of some conjugates to detect IgM antibody. The F/P ratios of those conjugates that could be determined varied from 2.6 to 17.8 μg of fluorescein per mg of protein. The need to identify and standardize both the immunologic capabilities and the optimum F/P ratio for FTA-ABS test conjugates is presented. PMID:4564403
Tyrosine-Nitrated Proteins: Proteomic and Bioanalytical Aspects
Batthyány, Carlos; Bartesaghi, Silvina; Mastrogiovanni, Mauricio; Lima, Analía; Demicheli, Verónica
2017-01-01
Abstract Significance: “Nitroproteomic” is under active development, as 3-nitrotyrosine in proteins constitutes a footprint left by the reactions of nitric oxide-derived oxidants that are usually associated to oxidative stress conditions. Moreover, protein tyrosine nitration can cause structural and functional changes, which may be of pathophysiological relevance for human disease conditions. Biological protein tyrosine nitration is a free radical process involving the intermediacy of tyrosyl radicals; in spite of being a nonenzymatic process, nitration is selectively directed toward a limited subset of tyrosine residues. Precise identification and quantitation of 3-nitrotyrosine in proteins has represented a “tour de force” for researchers. Recent Advances: A small number of proteins are preferential targets of nitration (usually less than 100 proteins per proteome), contrasting with the large number of proteins modified by other post-translational modifications such as phosphorylation, acetylation, and, notably, S-nitrosation. Proteomic approaches have revealed key features of tyrosine nitration both in vivo and in vitro, including selectivity, site specificity, and effects in protein structure and function. Critical Issues: Identification of 3-nitrotyrosine-containing proteins and mapping nitrated residues is challenging, due to low abundance of this oxidative modification in biological samples and its unfriendly behavior in mass spectrometry (MS)-based technologies, that is, MALDI, electrospray ionization, and collision-induced dissociation. Future Directions: The use of (i) classical two-dimensional electrophoresis with immunochemical detection of nitrated proteins followed by protein ID by regular MS/MS in combination with (ii) immuno-enrichment of tyrosine-nitrated peptides and (iii) identification of nitrated peptides by a MIDAS™ experiment is arising as a potent methodology to unambiguously map and quantitate tyrosine-nitrated proteins in vivo. Antioxid. Redox Signal. 26, 313–328. PMID:27324931
Qin, Hua-li; Zhou, Xue; Zhang, Wei; Chen, Si-xiu
2004-01-01
To examine the expressional change of nitric oxide synthase (NOS) in the injured dorsal root ganglia (DRG) and the ipsilateral adjacent uninjured DRG after selective dorsal rhizotomy. Immunochemical ABC method was used to detect the distribution of immunoreaction complex of NOS isoforms--nNOS and eNOS, and quantitative analysis was conducted to get the number of nNOS-immunoreactivity (nNOS-IR) neurons in normal DRG, dorsal rhizotomized DRG and spared DRG from adult cats on the 6th day after operation. This operating model was made by rhizotomizing unilateral L1-L5 dorsal roots and leaving L6 as a spared root. nNOS-immunoreactants were mainly distributed in the small-sized neurons in the DRG of cat. The percentage of nNOS-expressing small-sized neurons increased in the deafferentated L5 DRG (29.74%) when compared with the contralateral DRG (19.35%), and it also increased in the spared DRG (24.22%), compared with the contralateral DRG (18.61%). eNOS-IR was not observed in the DRG of adult cats. nNOS/NO up-regulated in DRG neurons is involved in a wide variety of biological functions under physiological and lesion-induced pathophysiological conditions in nerve system.
Fiber Optic Immunochemical Sensors For Continuous Monitoring Of Hapten Concentrations
NASA Astrophysics Data System (ADS)
Miller, W. Greg; Anderson, F. Philip
1989-06-01
We describe a fiber optic sensor based on a homogeneous fluorescence energy transfer immunoassay which operates in a continuous, reversible manner to quantitate the anticonvulsant drug phenytoin. B-phycoerythrin-phenytoin and Texas Red labeled anti-phenytoin antibody were sealed inside a short length of cellulose dialysis tubing which was cemented to the distal end of an optical fiber. When the sensor was placed into a solution of phenytoin, the drug crossed the dialysis membrane, displaced a fraction of the B-phycoerythrin-phenytoin from the antibody, and produced a change in fluorescence signal which was measured with a fiber optic fluorometer. The sensor had a concentration response of 5 to 500μmo1/L phenytoin with a response time of 5 to 15 min and precision of <2.5% CV. The chemical kinetics of the antibody-hapten indicator reaction were modeled mathematically and simulation showed that response time in the minutes range can be achieved when the dissociation rate constant is greater than approximately 10-3 sec-1. The dissociation rate constant influences the time to reach equilibrium and the unbound P* concentration range available for instrumental measurement. The ratio of the labeled and unlabeled hapten dissociation rate constants influences the analyte concentration range to which the sensor will respond.
In situ trans ligands of CD22 identified by glycan-protein photocross-linking-enabled proteomics.
Ramya, T N C; Weerapana, Eranthie; Liao, Lujian; Zeng, Ying; Tateno, Hiroaki; Liao, Liang; Yates, John R; Cravatt, Benjamin F; Paulson, James C
2010-06-01
CD22, a regulator of B-cell signaling, is a siglec that recognizes the sequence NeuAcalpha2-6Gal on glycoprotein glycans as ligands. CD22 interactions with glycoproteins on the same cell (in cis) and apposing cells (in trans) modulate its activity in B-cell receptor signaling. Although CD22 predominantly recognizes neighboring CD22 molecules as cis ligands on B-cells, little is known about the trans ligands on apposing cells. We conducted a proteomics scale study to identify candidate trans ligands of CD22 on B-cells by UV photocross-linking CD22-Fc chimera bound to B-cell glycoproteins engineered to carry sialic acids with a 9-aryl azide moiety. Using mass spectrometry-based quantitative proteomics to analyze the cross-linked products, 27 glycoproteins were identified as candidate trans ligands. Next, CD22 expressed on the surface of one cell was photocross-linked to glycoproteins on apposing B-cells followed by immunochemical analysis of the products with antibodies to the candidate ligands. Of the many candidate ligands, only the B-cell receptor IgM was found to be a major in situ trans ligand of CD22 that is selectively redistributed to the site of cell contact upon interaction with CD22 on the apposing cell.
Fungal proteomics: from identification to function.
Doyle, Sean
2011-08-01
Some fungi cause disease in humans and plants, while others have demonstrable potential for the control of insect pests. In addition, fungi are also a rich reservoir of therapeutic metabolites and industrially useful enzymes. Detailed analysis of fungal biochemistry is now enabled by multiple technologies including protein mass spectrometry, genome and transcriptome sequencing and advances in bioinformatics. Yet, the assignment of function to fungal proteins, encoded either by in silico annotated, or unannotated genes, remains problematic. The purpose of this review is to describe the strategies used by many researchers to reveal protein function in fungi, and more importantly, to consolidate the nomenclature of 'unknown function protein' as opposed to 'hypothetical protein' - once any protein has been identified by protein mass spectrometry. A combination of approaches including comparative proteomics, pathogen-induced protein expression and immunoproteomics are outlined, which, when used in combination with a variety of other techniques (e.g. functional genomics, microarray analysis, immunochemical and infection model systems), appear to yield comprehensive and definitive information on protein function in fungi. The relative advantages of proteomic, as opposed to transcriptomic-only, analyses are also described. In the future, combined high-throughput, quantitative proteomics, allied to transcriptomic sequencing, are set to reveal much about protein function in fungi. © 2011 Federation of European Microbiological Societies. Published by Blackwell Publishing Ltd. All rights reserved.
International review of cytology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bourne, G.H.; Jeon, K.W.; Friedlander, M.
1988-01-01
This book contains the following chapters: Transferrin and the growth-promoting effect of nerves; Nuclear functions and organization: The potential of immunochemical approaches; On the character of the secretory granules in juxtaglomerular eptihelioid cells; Protein secretions of sertoili cells; Problems of immune surveillance over the cytodifferentiation state and some cellular mechanisms of natural antitumor resistance; and Potassium estimation, uptake, and its role in the physiology and metabolism of flowering plants.
Effect of rising chemotherapy costs on the cost savings of colorectal cancer screening.
Lansdorp-Vogelaar, Iris; van Ballegooijen, Marjolein; Zauber, Ann G; Habbema, J Dik F; Kuipers, Ernst J
2009-10-21
Although colorectal cancer screening is cost-effective, it requires a considerable net investment by governments or insurance companies. If screening was cost saving, governments and insurance companies might be more inclined to invest in colorectal cancer screening programs. We examined whether colorectal cancer screening would become cost saving with the widespread use of the newer, more expensive chemotherapies. We used the MISCAN-Colon microsimulation model to assess whether widespread use of new chemotherapies would affect the treatment savings of colorectal cancer screening in the general population. We considered three scenarios for chemotherapy use: the past, the present, and the near future. We assumed that survival improved and treatment costs for patients diagnosed with advanced stages of colorectal cancer increased over the scenarios. Screening strategies considered were annual guaiac fecal occult blood testing (FOBT), annual immunochemical FOBT, sigmoidoscopy every 5 years, colonoscopy every 10 years, and the combination of sigmoidoscopy every 5 years and annual guaiac FOBT. Analyses were conducted from the perspective of the health-care system for a cohort of 50-year-old individuals who were at average risk of colorectal cancer and were screened with 100% adherence from age 50 years to age 80 years and followed up until death. Compared with no screening, the treatment savings from preventing advanced colorectal cancer and colorectal cancer deaths by screening more than doubled with the widespread use of new chemotherapies. The lifetime average treatment savings were larger than the lifetime average screening costs for screening with Hemoccult II, immunochemical FOBT, sigmoidoscopy, and the combination of sigmoidoscopy and Hemoccult II (average savings vs costs per individual in the population: Hemoccult II, $1398 vs $859; immunochemical FOBT, $1756 vs $1565; sigmoidoscopy, $1706 vs $1575; sigmoidoscopy and Hemoccult II $1931 vs $1878). Colonoscopy did not become cost saving, but the total net costs of this strategy decreased from $1317 to $296 per individual in the population. With the increase in chemotherapy costs for advanced colorectal cancer, most colorectal cancer screening strategies have become cost saving. As a consequence, screening is a desirable approach not only to reduce colorectal cancer incidence and mortality but also to control the costs of colorectal cancer treatment.
Volynsky, Pavel; Efremov, Roman; Mikhalev, Ilya; Dobrochaeva, Kira; Tuzikov, Alexander; Korchagina, Elena; Obukhova, Polina; Rapoport, Evgenia; Bovin, Nicolai
2017-10-01
Human blood contains a big variety of natural antibodies, circulating throughout life at constant concentration. Previously, we have found natural antibodies capable of binding to trisaccharide Galα1-4Galβ1-4Glc (P k ) practically in all humans. Intriguingly, the same trisaccharide is a key fragment of glycosphingolipid globotriaosylceramide (Gb3Cer) - normal component of erythrocyte and endothelial cell membrane, i.e. the antibodies and their cognate antigen coexist without any immunological reaction. To explain the inertness of human anti-P k antibodies towards own cells. We used a combination of immunochemical and molecular dynamics (MD) experiments. Antibodies were isolated using affinity media with P k trisaccharide, their epitope specificity was characterized using ELISA (enzyme-linked immunosorbent assay) with a set of synthetic glycans related to P k synthetic glycans and FACS (Fluorescence-Activated Cell Sorting) analysis of cells with inserted natural Gb3Cer and its synthetic analogue. Conformations and clustering of glycolipids immersed into a lipid bilayer were studied using MD simulations. Isolated specific antibodies were completely unable to bind natural Gb3Cer both inserted into cells and in artificial membrane, whereas strong interaction took place with synthetic analogue differing by the presence of a spacer between trisaccharide and lipid part. MD simulations revealed: i) although membrane-bound glycans do not form stable long-living aggregates, their transient packing is more compact in natural Gb3 as compared with the synthetic analog, ii) similar conformation of P k glycan in composition of the glycolipids, iii) no effect on the mentioned above results when cholesterol was inserted into membrane, and iv) better accessibility of the synthetic version for interaction with proteins. Both immunochemical and molecular dynamics data argue that the reason of the "tolerance" of natural anti-P k antibodies towards cell-bound Gb3Cer is the spatial inaccessibility of P k glycotope for interaction. We can conclude that the antibodies are not related to the blood group P system. Copyright © 2017 Elsevier Ltd. All rights reserved.
Comparison of Fecal Collection Methods for Microbiota Studies in Bangladesh
Chen, Jun; Kibriya, Muhammad G.; Chen, Yu; Islam, Tariqul; Eunes, Mahbubul; Ahmed, Alauddin; Naher, Jabun; Rahman, Anisur; Amir, Amnon; Shi, Jianxin; Abnet, Christian C.; Nelson, Heidi; Knight, Rob; Chia, Nicholas; Ahsan, Habibul; Sinha, Rashmi
2017-01-01
ABSTRACT To our knowledge, fecal microbiota collection methods have not been evaluated in low- and middle-income countries. Therefore, we evaluated five different fecal sample collection methods for technical reproducibility, stability, and accuracy within the Health Effects of Arsenic Longitudinal Study (HEALS) in Bangladesh. Fifty participants from the HEALS provided fecal samples in the clinic which were aliquoted into no solution, 95% ethanol, RNAlater, postdevelopment fecal occult blood test (FOBT) cards, and fecal immunochemical test (FIT) tubes. Half of the aliquots were frozen immediately at −80°C (day 0) and the remaining samples were left at ambient temperature for 96 h and then frozen (day 4). Intraclass correlation coefficients (ICC) were calculated for the relative abundances of the top three phyla, for two alpha diversity measures, and for four beta diversity measures. The duplicate samples had relatively high ICCs for technical reproducibility at day 0 and day 4 (range, 0.79 to 0.99). The FOBT card and samples preserved in RNAlater and 95% ethanol had the highest ICCs for stability over 4 days. The FIT tube had lower stability measures overall. In comparison to the “gold standard” method using immediately frozen fecal samples with no solution, the ICCs for many of the microbial metrics were low, but the rank order appeared to be preserved as seen by the Spearman correlation. The FOBT cards, 95% ethanol, and RNAlater were effective fecal preservatives. These fecal collection methods are optimal for future cohort studies, particularly in low- and middle-income countries. IMPORTANCE The collection of fecal samples in prospective cohort studies is essential to provide the opportunity to study the effect of the human microbiota on numerous health conditions. However, these collection methods have not been adequately tested in low- and middle-income countries. We present estimates of technical reproducibility, stability at ambient temperature for 4 days, and accuracy comparing a “gold standard” for fecal samples in no solution, 95% ethanol, RNAlater, postdevelopment fecal occult blood test cards, and fecal immunochemical test tubes in a study conducted in Bangladesh. Fecal occult blood test cards and fecal samples stored in 95% ethanol or RNAlater adequately preserve fecal samples in this setting. Therefore, new studies in low- and middle-income countries should include collection of fecal samples using fecal occult blood test cards, 95% ethanol, or RNAlater for prospective cohort studies. PMID:28258145
Chemo Resistance of Breast Cancer Stem Cells
2006-05-01
for stem cell markers , including CD44+ CD24- lin- by flow cytometry following chemotherapy residual tumor is assayed. As shown in Figure 3 below...the tumor and thus may contribute to relapse following therapy. This was to be accomplished by utilizing mouse xenograft models as well as markers ...limitation of utilizing these markers is that they are not suitable for immunochemical detection of tumor stem cells since they require flow cytometric
Immunochemical Investigations of Cell Surface Antigens of Anaerobic Bacteria.
1976-01-15
autopsies are nerformed on all animals. This includes a careful search of the abdominal cavity for evidence of peritonitis or abscesses . The criterion...for peritonitis is a free-flowing peritoneal exudate; for intraabdominal abscess it is a localized purulent collection. Bacteriological studies...expired. There were no further natural deaths after this time. i00-- _ _ _ PERITONIIS / ABSCESSES IN 80- SURVI\\’OPS PERITONITIS ABSCESS STAGE Z 60 STAGE,. w
NASA Astrophysics Data System (ADS)
Lebedev, A. A.; Davydov, V. Yu.; Novikov, S. N.; Litvin, D. P.; Makarov, Yu. N.; Klimovich, V. B.; Samoilovich, M. P.
2016-07-01
Results of developing and testing graphene-based sensors capable of detecting protein molecules are presented. The biosensor operation was checked using an immunochemical system comprising fluorescein dye and monoclonal antifluorescein antibodies. The sensor detects fluorescein concentration on a level of 1-10 ng/mL and bovine serum albumin-fluorescein conjugate on a level of 1-5 ng/mL. The proposed device has good prospects for use for early diagnostics of various diseases.
Cisar, J; Kabat, E A; Liao, J; Potter, M
1974-01-01
Four BALB/c IgA mouse myeloma proteins (W3129, W3434, QUPC 52, and UPC 102) reactive with dextran, four myeloma proteins reactive with fructosans, three IgA (W3082, UPC 61, and Y5476), and one IgG2a (UPC 10), and two human antilevans were studied immunochemically. Quantitative precipitin and inhibition assays showed that W3129, W3434, and QUPC 52 had specificities for isomaltose oligosaccharides similar to those previously found with alpha(1 --> 6)-specific human antidextrans. W3129 and W3434 were most complementary to IM5 but W3129 reacted equally with IM4 and IM3 while W3434 had a greater affinity for IM4 than IM3. QUPC 52 had a larger combining region and was most complementary to IM6. Protein UPC 102 (IgA), like MOPC 104E (IgM) (27), was most complementary to the alpha(1 --> 3)-linked trisaccharide, nigerotriose, and thus differed from J558 (29), which was inhibited best by nigeropentaose. UPC 102 was similar to J558 but they differed from MOPC 104E in their reactions with non-alpha(1 --> 3)-linked disaccharides. The fructosan-specific myeloma proteins fell into two groups with different specificities. The first group, W3082 (IgA), UPC 61 (IgA), and the previously studied J606 (IgG3) (28, 29), reacted with inulin and W3082 and UPC 61 appeared to have identical specificities for beta(2 --> 1)-linked fructofuranosyl residues with maximum complementarity for the tetrasaccharide betaDfructofuranosyl (2 --> 1)betaDfructofuranosyl(2 --> 1)betaDfructofuranosyl(2 --> 6)Dglucose while protein J606 was inhibited best by the trisaccharide betaDfructofuranosyl(2 --> 1)betaDfructofuranosyl(2 --> 6)Dglucose. W3082 and UPC 61 also differed from J606 in their behavior toward sucrose and betaDfructofuranosyl(2 --> 6)Dglucose as compared with alphaDglucosyl(1 --> 3)Dfructose (turanose). The second group containing myeloma proteins UPC 10 (IgG2a) and Y5476 (IgA) behaved similarly to human antilevans in that neither reacted with inulin nor were they inhibited by the beta(2 --> 1)-linked fructose oligosaccharides. Unlike the beta(2 --> 1)-specific proteins, they reacted with perennial rye grass levan that contained over 90% beta(2 --> 6)links. The differences in specificity and site size among homogeneous mouse myeloma proteins reactive with the same antigenic determinant are completely consistent with the concept that they represent products of homogeneous clones selected from the known heterogeneous population of antibody-forming cells.
Cubiella, Joaquín; Digby, Jayne; Rodríguez-Alonso, Lorena; Vega, Pablo; Salve, María; Díaz-Ondina, Marta; Strachan, Judith A; Mowat, Craig; McDonald, Paula J; Carey, Francis A; Godber, Ian M; Younes, Hakim Ben; Rodriguez-Moranta, Francisco; Quintero, Enrique; Álvarez-Sánchez, Victoria; Fernández-Bañares, Fernando; Boadas, Jaume; Campo, Rafel; Bujanda, Luis; Garayoa, Ana; Ferrandez, Ángel; Piñol, Virginia; Rodríguez-Alcalde, Daniel; Guardiola, Jordi; Steele, Robert J C; Fraser, Callum G
2017-05-15
Prediction models for colorectal cancer (CRC) detection in symptomatic patients, based on easily obtainable variables such as fecal haemoglobin concentration (f-Hb), age and sex, may simplify CRC diagnosis. We developed, and then externally validated, a multivariable prediction model, the FAST Score, with data from five diagnostic test accuracy studies that evaluated quantitative fecal immunochemical tests in symptomatic patients referred for colonoscopy. The diagnostic accuracy of the Score in derivation and validation cohorts was compared statistically with the area under the curve (AUC) and the Chi-square test. 1,572 and 3,976 patients were examined in these cohorts, respectively. For CRC, the odds ratio (OR) of the variables included in the Score were: age (years): 1.03 (95% confidence intervals (CI): 1.02-1.05), male sex: 1.6 (95% CI: 1.1-2.3) and f-Hb (0-<20 µg Hb/g feces): 2.0 (95% CI: 0.7-5.5), (20-<200 µg Hb/g): 16.8 (95% CI: 6.6-42.0), ≥200 µg Hb/g: 65.7 (95% CI: 26.3-164.1). The AUC for CRC detection was 0.88 (95% CI: 0.85-0.90) in the derivation and 0.91 (95% CI: 0.90-093; p = 0.005) in the validation cohort. At the two Score thresholds with 90% (4.50) and 99% (2.12) sensitivity for CRC, the Score had equivalent sensitivity, although the specificity was higher in the validation cohort (p < 0.001). Accordingly, the validation cohort was divided into three groups: high (21.4% of the cohort, positive predictive value-PPV: 21.7%), intermediate (59.8%, PPV: 0.9%) and low (18.8%, PPV: 0.0%) risk for CRC. The FAST Score is an easy to calculate prediction tool, highly accurate for CRC detection in symptomatic patients. © 2017 UICC.
Yamaori, Satoshi; Yamazaki, Hiroshi; Iwano, Shunsuke; Kiyotani, Kazuma; Matsumura, Keiko; Honda, Goro; Nakagawa, Kazuko; Ishizaki, Takashi; Kamataki, Tetsuya
2004-04-01
The purpose of this study was to evaluate a contribution of polymorphic cytochrome P450 (CYP) 3A5 to the oxidation of diltiazem, midazolam and testosterone by liver microsomes from Japanese subjects. Twenty-seven liver samples were classified into three groups according to the CYP3A5 genotypes; CYP3A5(*)1/(*)1 (n=3), (*)1/(*)3 (n=12) and (*)3/(*)3 (n=12). The results of genotyping and immunochemical quantitation of CYP3A5 protein showed a good accordance between the CYP3A5 genotype and CYP3A5 content but not CYP3A4 content in liver microsomes. The expression levels of hepatic CYP3A5 protein ranged from 20 to 60% of the sum of CYP3A4 and CYP3A5 contents in subjects with at least one wild type allele ((*)1). The CYP3A5 contents correlated well with liver microsomal activities of diltiazem N-demethylation, midazolam 1'- and 4-hydroxylations and testosterone 6beta-hydroxylation among subjects carrying at least one (*)1 allele. In addition, the correlation coefficients of CYP3A5 contents with the rates of diltiazem N-demethylation, midazolam 1'-hydroxylation and testosterone 6beta- hydroxylation were higher than those of CYP3A4, although the value of CYP3A5 with the midazolam 4-hydroxylation rate was similar to that of CYP3A4. Kinetic analyses revealed a biphasic diltiazem N-demethylation in liver microsomes from subjects carrying the (*)1 allele. The apparent V(max)/K(m) values for recombinant CYP3A5 indicated the greater contributions to diltiazem N-demethylation and midazolam 1'-hydroxylation as compared with CYP3A4. These results suggest that polymorphic CYP3A5 contributes markedly to the drug oxidations, particularly diltiazem N-demethylation, midazolam 1'- hydroxylation and testosterone 6beta-hydroxylation by liver microsomes from Japanese subjects.
Multitarget stool DNA testing for colorectal-cancer screening.
Imperiale, Thomas F; Ransohoff, David F; Itzkowitz, Steven H; Levin, Theodore R; Lavin, Philip; Lidgard, Graham P; Ahlquist, David A; Berger, Barry M
2014-04-03
An accurate, noninvasive test could improve the effectiveness of colorectal-cancer screening. We compared a noninvasive, multitarget stool DNA test with a fecal immunochemical test (FIT) in persons at average risk for colorectal cancer. The DNA test includes quantitative molecular assays for KRAS mutations, aberrant NDRG4 and BMP3 methylation, and β-actin, plus a hemoglobin immunoassay. Results were generated with the use of a logistic-regression algorithm, with values of 183 or more considered to be positive. FIT values of more than 100 ng of hemoglobin per milliliter of buffer were considered to be positive. Tests were processed independently of colonoscopic findings. Of the 9989 participants who could be evaluated, 65 (0.7%) had colorectal cancer and 757 (7.6%) had advanced precancerous lesions (advanced adenomas or sessile serrated polyps measuring ≥1 cm in the greatest dimension) on colonoscopy. The sensitivity for detecting colorectal cancer was 92.3% with DNA testing and 73.8% with FIT (P=0.002). The sensitivity for detecting advanced precancerous lesions was 42.4% with DNA testing and 23.8% with FIT (P<0.001). The rate of detection of polyps with high-grade dysplasia was 69.2% with DNA testing and 46.2% with FIT (P=0.004); the rates of detection of serrated sessile polyps measuring 1 cm or more were 42.4% and 5.1%, respectively (P<0.001). Specificities with DNA testing and FIT were 86.6% and 94.9%, respectively, among participants with nonadvanced or negative findings (P<0.001) and 89.8% and 96.4%, respectively, among those with negative results on colonoscopy (P<0.001). The numbers of persons who would need to be screened to detect one cancer were 154 with colonoscopy, 166 with DNA testing, and 208 with FIT. In asymptomatic persons at average risk for colorectal cancer, multitarget stool DNA testing detected significantly more cancers than did FIT but had more false positive results. (Funded by Exact Sciences; ClinicalTrials.gov number, NCT01397747.).
Purification and Thermal Stability of Intact Bacillus subtilis Flagella
Dimmitt, K.; Simon, M.
1971-01-01
Flagella were prepared and purified in a relatively intact form from bacterial lysates. Immunochemical tests showed that over 95% of the protein in the final preparation consisted of flagellar antigen. These flagella are more stable to thermal denaturation than flagella filaments obtained by shearing. Their thermal properties more closely resemble those of flagella in the native state on bacteria. The presence of the hook structure is responsible for this extra stability. Images PMID:4993323
Studies on the Immunochemical Techniques for Detection of Selected Fungal and Dinoflagellate Toxins.
1985-08-15
to be one of the most potent protein inhibitors. It has been found to be associated with several natural outbreaks of mycotoxicoses in both animals...trichothecene mycotoxins and dinoflagellate phytotoxins and subsequently to develop a radioimmunoassay (RIA) or an enzyme-linked immunosorbent assay...of 7% and variation coeffecient of 8%. The minumal detection for DON was around 20 ppb. The application of this method to limited naturally
Devices for home evaluation of women's health concerns.
Scolaro, Kelly L; Lloyd, Kimberly Braxton; Helms, Kristen L
2008-02-15
Devices used for home evaluation of fertility, pregnancy, menopause, colon cancer, breast cancer, and urinary-tract and vaginal yeast infections are discussed. Ovulation-prediction devices monitor natural changes in a woman's body during the menstrual cycle, including changes in basal body temperature, urinary luteinizing hormone, and urinary estrone-3-glucuronide concentrations. Also available are devices that identify changes in the content of sodium chloride and other electrolytes in saliva and cervical-vaginal mucus. Home pregnancy tests are designed to detect human chorionic gonadotropin in the urine. Both urine and saliva tests are available for home evaluation of menopause; the most common devices use urine to measure follicle-stimulating hormone. The saliva tests measure estradiol, progesterone, and testosterone. Devices for home screening for colon cancer use either the guaiac test or the fecal immunochemical test. For aid in breast self-examination, patients may use a simulated-breast product designed to train them to detect lumps or a thin, silicone-containing pad intended to increase the sensitivity of the fingers to abnormalities. Urine-dipstick tests can be used to screen for urinary-tract infection, and a swab or panty liner can be used to detect vaginal pH changes indicative of vaginal yeast infection. Home-based tests may be convenient and economical but also have limitations; pharmacists can help educate patients and clinicians. Many devices are available to help evaluate women's health concerns at home.
Akpak, Yaşam Kemal; Çekmez, Yasemin; Erdoğan Çakır, Aslı; Karaca, Nilay; Batmaz, Gonca; Gülşen, Serdar; Tuştaş Haberal, Esra
2017-12-01
This study aims at evaluating the endometrial receptivity in uterus of pregnant rats exposed to nicotine via examination of integrin expression by immunohistochemical effect. In this study, 16 healthy pregnant rats were divided into two groups of control and study groups each comprising eight rats. The rats randomised to study group were given a certain amount of nicotine before and during the pregnancy. Integrin expression was detected in uterus of all rats by immunohistochemical staining. The effect of nicotine exposure on embryo implantation and the endometrial receptivity were immunohistochemically and pathologically evaluated. Comparison of both groups revealed no difference in living, viable foetuses. Intensity and universality of immunohistochemical staining of Integrin β3 for endometrial epithelium and endometrial stroma were detected to be identical between the groups. No immunochemical effect was observed on integrin expression, which is a very important part of receptivity in an animal model created with pregnant rats that were transdermally exposed to nicotine. Our study demonstrated that the harmful effect of nicotine use before and pregnancy on implantation is limited at the level of integrin expression, in a dose-dependent manner and also by considering the method of administration.
Hannon, Peggy A; Vu, Thuy; Ogdon, Sara; Fleury, Emily M; Yette, Emily; Wittenberg, Reva; Celedonia, Megan; Bowen, Deborah J
2013-03-01
Colorectal cancer screening is a life-saving intervention, but screening rates are low. The authors implemented and evaluated the Spokane Colorectal Cancer Screening Program-a novel worksite intervention to promote colorectal cancer screening that used a combination of evidence-based strategies recommended by the Guide to Community Preventive Services, as well as additional strategies. Over a period of approximately 3 months, participating worksites held one or more physician-led seminars about colorectal cancer screening for employees. They also distributed free fecal immunochemical tests at the worksite to employees 50 years and older, and they provided test results to employees and their primary care physician. The authors measured attendance at seminars, test kits taken and returned, employee awareness of the program, and colorectal cancer screening rates in participating and comparison worksites. It is estimated that 9% of eligible employees received kits at the worksite, and 4% were screened with these kits. The Spokane Colorectal Cancer Screening Program was a promising pilot test of an innovative worksite screening program that successfully translated evidence-based strategies into practical use in a brief period of time, and it merits a larger study to be able to test its effects more rigorously.
Colon cancer screening: which non-invasive filter tests?
Pox, Christian
2011-01-01
The following non-invasive stool tests for colorectal cancer (CRC) screening exist: guaiac or immunochemical fecal occult blood testing (FOBT), genetic stool tests and the M2-PK. Currently the most widely used tests are guaiac-based (gFOBT). Several randomized controlled trials have shown that gFOBT are able to achieve a reduction in CRC-related mortality. This reduction is achieved by detecting asymptomatic cancers at an early stage with a better prognosis. However, gFOBT have a low sensitivity for colorectal adenomas and are thus unlikely to be able to reduce the incidence of CRC. Furthermore, gFOBT are not specific for human blood and can be influenced by external factors. Immunochemical tests (iFOBT) only detect human blood in the stool. In two recent randomized studies from the Netherlands comparing guaiac and immunochemical tests in the asymptomatic population, iFOBT were found to detect more cancers than gFOBT. Furthermore, iFOBT were able to detect more advanced adenomas thus having the potential to be able to reduce the incidence of CRC as well as CRC-related mortality. In the recently released European CRC screening guidelines, iFOBT are considered the screening test of choice. Several questions remain however. It is currently unknown what the optimal cut-off value for an iFOBT to be considered positive should be and what the number of stool samples is that are required. Genetic stool tests detect mutations in stool that can be found in CRC. The original test testing for 21 genetic changes was found to be superior to gFOBT for the detection of cancers. However, the sensitivity was moderate (51.6%) and the sensitivity for advanced adenomas was low. In the meantime the test has been modified improving DNA extraction and reducing the number of mutations tested for as well as including a methylation marker. The efficacy of the modified test in the screening population is unknown. M2-PK is an isomer of the enzyme pyruvate kinase that is involved in glycolysis. Studies have found a good sensitivity for cancers, a low sensitivity for advanced adenomas with a specificity of around 80%. Further studies in the screening population are required. Copyright © 2011 S. Karger AG, Basel.
[Cost-effectiveness analysis on colorectal cancer screening program].
Huang, Q C; Ye, D; Jiang, X Y; Li, Q L; Yao, K Y; Wang, J B; Jin, M J; Chen, K
2017-01-10
Objective: To evaluate the cost-effectiveness of colorectal cancer screening program in different age groups from the view of health economics. Methods: The screening compliance rates, detection rates in different age groups were calculated by using the data from colorectal cancer screening program in Jiashan county, Zhejiang province. The differences in indicator among age groups were analyzed with χ (2) test or trend χ (2) test. The ratios of cost to the number of case were calculated according to cost statistics. Results: The detection rates of immunochemical fecal occult blood test (iFOBT) positivity, advanced adenoma and colorectal cancer and early stage cancer increased with age, while the early diagnosis rates were negatively associated with age. After exclusion the younger counterpart, the cost-effectiveness of individuals aged >50 years could be reduced by 15 %- 30 % . Conclusion: From health economic perspective, it is beneficial to start colorectal cancer screening at age of 50 years to improve the efficiency of the screening.
Wang, Fan; Xiao, Mi; Chen, Ru-Juan; Lin, Xiao-Jie; Siddiq, Muhammad; Liu, Li
2017-02-01
To evaluate the effect of regulatory T cells (Tregs) on the inflammation resulting from lipopolysaccharide (LPS) challenge in prenatal brain tissue, Tregs isolated from pregnant mice were transferred into model mice, and the expression levels of fork head family transcription factor (Foxp3), interleukin-6 (IL-6), CD68 (a marker of microglia), and toll-like receptor 4 (TLR-4) were assessed in the fetal brain tissue. Foxp3, IL-6, and TLR-4 expression were detected by polymerase chain reaction and Western blot; CD68 expression level was detected using immunochemical analysis. Foxp3, IL-6, TLR-4, and CD68 expressions in fetal brain were significantly induced by maternal LPS administration, and the increased expression levels were markedly reduced by adoptive transfer of Tregs. Maternal LPS exposure significantly induced inflammation in perinatal brain tissue, and Tregs negatively regulated this LPS-induced inflammation. © 2016 International Federation for Cell Biology.
Kawai, Yoshichika
2011-01-01
It has been suggested that polyphenol-rich diets decrease the risk of cardiovascular diseases. Although studies of the bioavailability of polyphenols, particularly their absorption and metabolism, have been reported recently, the tissue and cellular distributions underlying their biological mechanisms remain unknown. It is difficult to evaluate the specific localization of tissue and/or cellular polyphenols, because the method is limited to chromatography. To overcome these difficulties, we have developed anti-polyphenol antibodies to characterize immunohistochemically the localization of polyphenols and their metabolites in vivo. Two novel monoclonal antibodies were raised against quercetin and tea catechins, which represent flavonoid-type polyphenols distributed in foods and beverages, and are expected to exhibit anti-oxidative and anti-inflammatory activities in vivo. Using these antibodies, we identified activated macrophages as a specific target of these flavonoids during the development of atherosclerotic lesions. This review describes recent findings on the molecular actions of flavonoids that underly their anti-atherosclerotic activity in vivo.
Boncela, Joanna; Smolarczyk, Katarzyna; Kowalewski, Cezary; Wozniak, Katarzyna; Torzecka, Jolanta Dorota; Sysa-Jedrzejowska, Anna; Cierniewski, Czesław S.; Lesiak, Aleksandra
2012-01-01
Introduction There are scarce data on immunochemical properties of pemphigus antibodies detected in clinical remission in pemphigus vulgaris (PV) patients. The aim of the study was to compare biological activity of anti-Dsg3 autoantibodies purified from the sera of PV patients in active stage and in clinical remission. Material and methods The effect of purified antibodies on expression of procaspase-3, Bax, Bcl-2, uPAR, IL-1β, IL-6, and TNF-α mRNAs in the HaCaT keratinocytes was evaluated by Western blot and RT-PCR method. Results Incubation of HaCaT cells with anti-Dsg-3 autoantibodies caused their binding to cell membranes surfaces. Anti-Dsg3 autoantibodies isolated from the patients in active stage and clinical remission showed proapoptotic effect, caused enhanced expression of analyzed proinflammatory cytokines’ mRNAs and uPAR mRNA. Conclusions Our data revealed similar pathogenic activity of anti Dsg-3 autoantibodies isolated from active and clinical remission PV patients. PMID:22662010
Toes-Zoutendijk, Esther; van Leerdam, Monique E; Dekker, Evelien; van Hees, Frank; Penning, Corine; Nagtegaal, Iris; van der Meulen, Miriam P; van Vuuren, Anneke J; Kuipers, Ernst J; Bonfrer, Johannes M G; Biermann, Katharina; Thomeer, Maarten G J; van Veldhuizen, Harriët; Kroep, Sonja; van Ballegooijen, Marjolein; Meijer, Gerrit A; de Koning, Harry J; Spaander, Manon C W; Lansdorp-Vogelaar, Iris
2017-03-01
After careful pilot studies and planning, the national screening program for colorectal cancer (CRC), with biennial fecal immunochemical tests (FITs), was initiated in The Netherlands in 2014. A national information system for real-time monitoring was developed to allow for timely evaluation. Data were collected from the first year of this screening program to determine the importance of planning and monitoring for optimal screening program performance. The national information system of the CRC screening program kept track of the number of invitations sent in 2014, FIT kits returned, and colonoscopies performed. Age-adjusted rates of participation, the number of positive test results, and positive predictive values (PPVs) for advanced neoplasia were determined weekly, quarterly, and yearly. In 2014, there were 741,914 persons invited for FIT; of these, 529,056 (71.3%; 95% CI, 71.2%-71.4%) participated. A few months into the program, real-time monitoring showed that rates of participation and positive test results (10.6%; 95% CI, 10.5%-10.8%) were higher than predicted and the PPV was lower (42.1%; 95% CI, 41.3%-42.9%) than predicted based on pilot studies. To reduce the burden of unnecessary colonoscopies and alleviate colonoscopy capacity, the cut-off level for a positive FIT result was increased from 15 to 47 μg Hb/g feces halfway through 2014. This adjustment decreased the percentage of positive test results to 6.7% (95% CI, 6.6%-6.8%) and increased the PPV to 49.1% (95% CI, 48.3%-49.9%). In total, the first year of the Dutch screening program resulted in the detection of 2483 cancers and 12,030 advanced adenomas. Close monitoring of the implementation of the Dutch national CRC screening program allowed for instant adjustment of the FIT cut-off levels to optimize program performance. Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.
Zorzi, Manuel; Senore, Carlo; Da Re, Filippo; Barca, Alessandra; Bonelli, Luigina Ada; Cannizzaro, Renato; de Pretis, Giovanni; Di Furia, Lucia; Di Giulio, Emilio; Mantellini, Paola; Naldoni, Carlo; Sassatelli, Romano; Rex, Douglas K; Zappa, Marco; Hassan, Cesare
2017-07-01
To assess detection rate and predictive factors of sessile serrated polyps (SSPs) in organised colorectal cancer (CRC) screening programmes based on the faecal immunochemical test (FIT). Data from a case series of colonoscopies of FIT-positive subjects were provided by 44 Italian CRC screening programmes. Data on screening history, endoscopic procedure and histology results, and additional information on the endoscopy centre and the endoscopists were collected, including the age-standardised and sex-standardised adenoma detection rate (ADR) of the individual endoscopists. The SSP detection rate (SSP-DR) was assessed for the study population. To identify SSP-predictive factors, multilevel analyses were performed according to patient/centre/endoscopist characteristics. We analysed 72 021 colonoscopies, of which 1295 presented with at least one SSP (SSP-DR 1.8%; 95% CI 1.7% to 1.9%). At the per-patient level, SSP-DR was associated with males (OR 1.35; 95% CI 1.17 to 1.54) and caecal intubation (OR 3.75; 95% CI 2.22 to 6.34), but not with the FIT round. The presence of at least one advanced adenoma was more frequent among subjects with SSPs than those without (OR 2.08; 95% CI 1.86 to 2.33). At the per-endoscopist level, SSP-DR was associated with ADR (third vs first ADR quartile: OR 1.55; 95% CI 1.03 to 2.35; fourth vs first quartile: OR 1.89; 95% CI 1.24 to 2.90). The low prevalence of SSPs and the lack of association with the FIT round argue against SSP as a suitable target for FIT-based organised programmes. Strict association of SSP-DR with the key colonoscopy quality indicators, namely caecal intubation rate and high ADR further marginalises the need for SSP-specific quality indicators in FIT-based programmes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Immunochemical Investigations of Cell Surface Antigens of Anaerobic Bacteria
1977-01-15
sterile cecal contents were included in all inocula, our data indicates * that cecal contents from germ free rats can be used in place of sterile cecal...The void volume of the column was estimated with blue dextran. Molecular size of the un- digested Pool 1 material was estimated using a PM-30 membrane...51) using bovine serum albumin as a standard. Total sugars were measured by the phenol-sulfuric acid method (52) using glucose as a standards
Phase 2 SBIR Final Report: An Ultra-Sensitive Optical Biosensor for Flood Safety
2002-08-23
can be completed in 2 to 4 hours. Currently accepted tests using commercial test kits based on immunochemical techniques offer results in 22 to 24...tagging is imperfect, leading to a background of non-specific surface and molecular binding limiting the signal. The use of a reporter fluorochrome can ...Waveguide Patterning: Surface flow channels: The rectangular cuvettes (as shown in Section II, Figure 4-3) can be etched using standard techniques. The
1981-01-01
incubated for an additional 10 min at 22°C. Immune rene test tubes. Samples were withdrawn aseptically complexes were collected by centrifugation at 3.000... tested imme- of assay buffer, and the final pellets were counted with diately in an assay, and the other was frozen at -70°C. a Beckman Biogamma counter... tested before and after activation immunoadsorbent for immune complexes containing with urea and dithiothreitol (13). Enzyme neutraliza
Cai, Shan-Rong; Zhu, Hong-Hong; Huang, Yan-Qin; Li, Qi-Long; Ma, Xin-Yuan; Zhang, Su-Zhan; Zheng, Shu
2016-01-01
This study investigated the cost-effectiveness between double and single Fecal Immunochemical Test(s) (FIT) in a mass CRC screening. A two-stage sequential screening was conducted. FIT was used as a primary screening test and recommended twice by an interval of one week at the first screening stage. We defined the first-time FIT as FIT1 and the second-time FIT as FIT2. If either FIT1 or FIT2 was positive (+), then a colonoscopy was recommended at the second stage. Costs were recorded and analyzed. A total of 24,419 participants completed either FIT1 or FIT2. The detection rate of advanced neoplasm was 19.2% among both FIT1+ and FIT2+, especially high among men with age ≥55 (27.4%). About 15.4% CRC, 18.9% advanced neoplasm, and 29.9% adenoma missed by FIT1 were detected by FIT2 alone. Average cost was $2,935 for double FITs and $2,121 for FIT1 to detect each CRC and $901 for double FITs and $680 for FIT1 to detect each advanced neoplasm. Double FITs are overall more cost-effective, having significantly higher positive and detection rates with an acceptable higher cost, than single FIT. Double FITs should be encouraged for the first screening in a mass CRC screening, especially in economically and medically underserved populations/areas/countries.
Baxter, Nielson T; Koumpouras, Charles C; Rogers, Mary A M; Ruffin, Mack T; Schloss, Patrick D
2016-11-14
There is a significant demand for colorectal cancer (CRC) screening methods that are noninvasive, inexpensive, and capable of accurately detecting early stage tumors. It has been shown that models based on the gut microbiota can complement the fecal occult blood test and fecal immunochemical test (FIT). However, a barrier to microbiota-based screening is the need to collect and store a patient's stool sample. Using stool samples collected from 404 patients, we tested whether the residual buffer containing resuspended feces in FIT cartridges could be used in place of intact stool samples. We found that the bacterial DNA isolated from FIT cartridges largely recapitulated the community structure and membership of patients' stool microbiota and that the abundance of bacteria associated with CRC were conserved. We also found that models for detecting CRC that were generated using bacterial abundances from FIT cartridges were equally predictive as models generated using bacterial abundances from stool. These findings demonstrate the potential for using residual buffer from FIT cartridges in place of stool for microbiota-based screening for CRC. This may reduce the need to collect and process separate stool samples and may facilitate combining FIT and microbiota-based biomarkers into a single test. Additionally, FIT cartridges could constitute a novel data source for studying the role of the microbiome in cancer and other diseases.
Immunochemical analysis of Micrococcus lysodeikticus (luteus) F1-ATPase and its subunits.
Urban, C; Salton, M R
1983-08-31
The F1-ATPase from Micrococcus lysodeikticus has been purified to 95% protein homogeneity in this laboratory and as all other bacterial F1S, possesses five distinct subunits with molecular weights ranging from 60 000 to 10 000 (Huberman, M. and Salton, M.R.J. (1979) Biochim. Biophys. Acta 547, 230-240). In this communication, we demonstrate the immunochemical reactivities of antibodies to native and SDS-dissociated subunits with the native and dissociated F1-ATPase and show that: (1) the antibodies generated to the native or SDS-dissociated subunits react with the native molecule; (2) all of the subunits comprising the F1 are antigenically unique as determined by crossed immunoelectrophoresis and the Ouchterlony double-diffusion techniques; (3) antibodies to the SDS-denatured individual delta- and epsilon-subunits can be used to destabilize the interaction of these specific subunits with the rest of the native F1; and (4) all subunit antibodies as well as anti-native F1 were found to inhibit ATPase activity to varying degrees, the strongest inhibition being seen with antibodies to the total F1 and anti-alpha- and anti-beta-subunit antibodies. The interaction of specific subunit antibodies may provide a new and novel way to study further and characterize the catalytic portions of F1-ATPases and in general may offer an additional method for the examination of multimeric proteins.
Li, Wen; Zhao, Li-Zhong; Ma, Dong-Wang; Wang, De-Zheng; Shi, Lei; Wang, Hong-Lei; Dong, Mo; Zhang, Shu-Yi; Cao, Lei; Zhang, Wei-Hua; Zhang, Xi-Peng; Zhang, Qing-Huai; Yu, Lin; Qin, Hai; Wang, Xi-Mo; Chen, Sam Li-Sheng
2018-05-01
We aimed to predict colorectal cancer (CRC) based on the demographic features and clinical correlates of personal symptoms and signs from Tianjin community-based CRC screening data.A total of 891,199 residents who were aged 60 to 74 and were screened in 2012 were enrolled. The Lasso logistic regression model was used to identify the predictors for CRC. Predictive validity was assessed by the receiver operating characteristic (ROC) curve. Bootstrapping method was also performed to validate this prediction model.CRC was best predicted by a model that included age, sex, education level, occupations, diarrhea, constipation, colon mucosa and bleeding, gallbladder disease, a stressful life event, family history of CRC, and a positive fecal immunochemical test (FIT). The area under curve (AUC) for the questionnaire with a FIT was 84% (95% CI: 82%-86%), followed by 76% (95% CI: 74%-79%) for a FIT alone, and 73% (95% CI: 71%-76%) for the questionnaire alone. With 500 bootstrap replications, the estimated optimism (<0.005) shows good discrimination in validation of prediction model.A risk prediction model for CRC based on a series of symptoms and signs related to enteric diseases in combination with a FIT was developed from first round of screening. The results of the current study are useful for increasing the awareness of high-risk subjects and for individual-risk-guided invitations or strategies to achieve mass screening for CRC.
Ashwini; Umashankar, K; Rajiv, Jyotsna; Prabhasankar, P
2016-01-01
A high demand exists for gluten free and hypoimmunogenic products from gluten sensitive population. The present study focuses on the development of hypoimmunogenic muffins using a combination of the blend (CB) consisting of modified (protease treated) Whole Wheat Flour (WWF) and Pearl Millet Flour (PMF). The batter density of CB was 0.97, and it varied between 0.91-0.93 and 0.97-0.99 g/cc with the use of emulsifiers and hydrocolloids respectively. The volume of the muffin made using CB was 70 mL, and it increased to 120 mL with the combination of additives (CAD) comprising of Carboxy Methyl Cellulose (CMC) and Polysorbate-60 (PS-60). The muffins made of CB + CAD had the lowest hardness (19.8 N) and gumminess (6.6 N) values and highest springiness value (13.3 mm) indicating that the texture was soft. Sensory characteristics of the muffin made with CB + CAD were good and had an overall quality score of 90.5 out of 100. Rheometer studies showed that the incorporation of additives improved the visco-elastic properties of muffin batters. Microstructure studies showed a change in gluten matrix of muffins followed by treatments. Immunochemical validation of muffins made using CB + CAD showed that the immunogenicity reduced by 70.8 % which may be suitable for patients with gluten sensitivity.
[BIOLOGICAL AND IMMUNOCHEMICAL PROPERTIES OF POLYREACTIVE IMMUNOGLOBULINS].
Bobrovnik, S A; Demchenko, M A; Komisarenko, S V
2015-01-01
A previously unknown phenomenon of acquired polyreactivity for serum immunoglobulins, which were subjected either to solutions of KSCN (3.0-5.0 M), low/high pH (pH 2.2-3.0), or heating to 58-60 degrees C, was described by us in 1990 year. Much later, eleven years after that, similar data were published by others, which completely confirmed our results concerning the influence of either chaotropic ions or the drastic shift of pH on immunoglobulins polyreactive properties. Our further investigations of polyreactive serum immunoglobulins (PRIG) properties have shown that the mechanism of non-specific interaction between PRIG and antigens much differs from the mechanism of interaction between specific antibodies and corresponding antigens. Later we have shown that the increasing of PRIG reactivity could be induced in vivo, and PRIG are one of serum components for human or animal sera. Then, it could be suggested that PRIG can perform certain biological functions. Studying of PRIG's effect on the phagocytosis of microbes by peritoneal cells or the tumor growth have shown that PRIG can play a certain role in protecting the body from infections and probably can influence on the development of various pathological processes. Recently we have also found that PRIG IgG contents significantly increases in aged people. These data demonstrate that further investigations of PRIG's immunochemical properties and studying of their biological role in organism protection from various diseases is very intriguing and important.
1990-09-01
90% of all radioactivity. Mustard gas appeared to be a very effective alkylating agent for bases in DNA. Even in blood, with a variety of reactive...stranded than of the single-stranded material is required for effective competition in the ELISA test, probably as a result of interstrand crosslinks...first noticed by their effects on casualties. If a total ban on the use, possession and production of chemical agents will eventually materialize, the
Studies on the Immunochemical Techniques for Detection of Selected Fungal and Dinoflagellate Toxins
1983-08-15
was tested. Alpha epimer ( natural form) was found to be more effective than the beta form in the RIA. Not only was much less antibody required, the...with tritiated reduced-VT, DAS, T-2, and DOVE. After completion of these studies, we should be able to understand the nature of such antibodies and to...the ELISA. The nature of the cross-linking of the toxin to BSA is poorly understood. Further studies should be directed to characterize the reaction
Chauhan, Ritika; Chauhan, Vinita; Rao, Mula Kameshwar; Chaudhary, Dilip; Bhagyawant, Sameer; Dhaked, Ram Kumar
2018-06-01
Botulinum neurotoxins (BoNTs) are the most toxic biological substances known. Their potential use as biological warfare agent results in their classification as category A biowarfare agent by Centers for Disease Control and Prevention (CDC), USA. Presently, there are no approved detection system and pharmacological treatments for BoNT intoxication. Although a toxoid vaccine is available for immuno-prophylaxis, vaccines cannot reverse the effect of pre-translocated toxin. Direct handling of the live BoNTs for developing detection and therapeutics may pose fatal danger. This concern was addressed by purifying the recombinant catalytically active light chain of BoNT/F. BoNT/F-LC gene was amplified from the genomic DNA using specifically designed primers and expressed in Escherichia coli. Expression and purification profile were optimized under different conditions for biologically active light chain production. Specific polyclonal antibodies generated against type F illustrates in vivo neutralization in mice and rabbit. These antibodies play key role in conceiving the development of high throughput SPR based detection system which is a highly precise label free technique for protein interaction analysis. The presented work is first of its kind, signifying the production of highly stable and active rBoNT/F-LC and its immunochemical characterization. The study aids in paving the path towards developing a persistent detection system as well as in presenting comprehended scheme for in vitro small molecule therapeutics analysis. Copyright © 2018 Elsevier Inc. All rights reserved.
van Rossum, Leo G M; van Rijn, Anne F; Verbeek, Andre L M; van Oijen, Martijn G H; Laheij, Robert J F; Fockens, Paul; Jansen, Jan B M J; Adang, Eddy M M; Dekker, Evelien
2011-04-15
Comparability of cost-effectiveness of colorectal cancer (CRC) screening strategies is limited if heterogeneous study data are combined. We analyzed prospective empirical data from a randomized-controlled trial to compare cost-effectiveness of screening with either one round of immunochemical fecal occult blood testing (I-FOBT; OC-Sensor®), one round of guaiac FOBT (G-FOBT; Hemoccult-II®) or no screening in Dutch aged 50 to 75 years, completed with cancer registry and literature data, from a third-party payer perspective in a Markov model with first- and second-order Monte Carlo simulation. Costs were measured in Euros (€), effects in life-years gained, and both were discounted with 3%. Uncertainty surrounding important parameters was analyzed. I-FOBT dominated the alternatives: after one round of I-FOBT screening, a hypothetical person would on average gain 0.003 life-years and save the health care system €27 compared with G-FOBT and 0.003 life years and €72 compared with no screening. Overall, in 4,460,265 Dutch aged 50-75 years, after one round I-FOBT screening, 13,400 life-years and €320 million would have been saved compared with no screening. I-FOBT also dominated in sensitivity analyses, varying uncertainty surrounding important effect and cost parameters. CRC screening with I-FOBT dominated G-FOBT and no screening with or without accounting for uncertainty. Copyright © 2010 UICC.
Doubeni, Chyke A.; Jensen, Christopher D.; Fedewa, Stacey A.; Quinn, Virginia P.; Zauber, Ann G.; Schottinger, Joanne E.; Corley, Douglas A.; Levin, Theodore R.
2017-01-01
Introduction Fecal immunochemical tests (FITs) are widely used in colorectal cancer (CRC) screening, but hemoglobin degradation, due to exposure of the collected sample to high temperatures, could reduce test sensitivity. We examined the relation of ambient temperature exposure with FIT positivity rate and sensitivity. Methods This was a retrospective cohort study of patients 50 to 75 years in Kaiser Permanente Northern California’s CRC screening program, which began mailing FIT kits annually to screen-eligible members in 2007. Primary outcomes were FIT positivity rate and sensitivity to detect CRC. Predictors were month, season, and daily ambient temperatures of test result dates based on US National Oceanic and Atmospheric Administration data. Results Patients (n =472,542) completed 1,141,162 FITs. Weekly test positivity rate ranged from 2.6% to 8.0% (median, 4.4%) and varied significantly by month (June/July vs December/January rate ratio [RR] =0.79, 95% confidence interval [CI], 0.76 to 0.83) and season. FIT sensitivity was lower in June/July (74.5%; 95% CI, 72.5 to 76.6) than January/December (78.9%; 95% CI, 77.0 to 80.7). Conclusions FITs completed during high ambient temperatures had lower positivity rates and lower sensitivity. Changing kit design, specimen transportation practices, or avoiding periods of high ambient temperatures may help optimize FIT performance, but may also increase testing complexity and reduce patient adherence, requiring careful study. PMID:28076249
Crosby, Richard A; Stradtman, Lindsay; Collins, Tom; Vanderpool, Robin
2017-09-01
To determine the return rate of community-delivered fecal immunochemical test (FIT) kits in a rural population and to identify significant predictors of returning kits. Residents were recruited in 8 rural Kentucky counties to enroll in the study and receive an FIT kit. Of 345 recruited, 82.0% returned an FIT kit from the point of distribution. These participants were compared to the remainder relative to age, sex, marital status, having an annual income below $15,000, not graduating from high school, not having a regular health care provider, not having health care coverage, being a current smoker, indicating current overweight or obese status, and a scale measure of fatalism pertaining to colorectal cancer. Predictors achieving significance at the bivariate level were entered into a stepwise logistic regression model to calculate adjusted OR and 95% CI. The return rate was 82.0%. In adjusted analyses, those indicating an annual income of less than $15,000 were 2.85 times more likely to return their kits (95% CI: 1.56-5.24; P < .001). Also, those not perceiving themselves to be overweight/obese were 1.95 times more likely to return their kits (95% CI: 1.07-3.55; P = .029). An outreach-based colorectal cancer screening program in a rural population may yield high return rates. People with annual incomes below $15,000 and those not having perceptions of being overweight/obese may be particularly likely to return FIT kits. © 2016 National Rural Health Association.
Post, Deborah M. B.; Ketterer, Margaret R.; Coffin, Jeremy E.; Reinders, Lorri M.; Munson, Robert S.; Bair, Thomas; Murphy, Timothy F.; Foster, Eric D.; Gibson, Bradford W.
2016-01-01
Haemophilus haemolyticus and nontypeable Haemophilus influenzae (NTHi) are closely related upper airway commensal bacteria that are difficult to distinguish phenotypically. NTHi causes upper and lower airway tract infections in individuals with compromised airways, while H. haemolyticus rarely causes such infections. The lipooligosaccharide (LOS) is an outer membrane component of both species and plays a role in NTHi pathogenesis. In this study, comparative analyses of the LOS structures and corresponding biosynthesis genes were performed. Mass spectrometric and immunochemical analyses showed that NTHi LOS contained terminal sialic acid more frequently and to a higher extent than H. haemolyticus LOS did. Genomic analyses of 10 strains demonstrated that H. haemolyticus lacked the sialyltransferase genes lic3A and lic3B (9/10) and siaA (10/10), but all strains contained the sialic acid uptake genes siaP and siaT (10/10). However, isothermal titration calorimetry analyses of SiaP from two H. haemolyticus strains showed a 3.4- to 7.3-fold lower affinity for sialic acid compared to that of NTHi SiaP. Additionally, mass spectrometric and immunochemical analyses showed that the LOS from H. haemolyticus contained phosphorylcholine (ChoP) less frequently than the LOS from NTHi strains. These differences observed in the levels of sialic acid and ChoP incorporation in the LOS structures from H. haemolyticus and NTHi may explain some of the differences in their propensities to cause disease. PMID:26729761
Christy, Shannon M; Davis, Stacy N; Williams, Kimberly R; Zhao, Xiuhua; Govindaraju, Swapomthi K; Quinn, Gwendolyn P; Vadaparampil, Susan T; Lin, Hui-Yi; Sutton, Steven K; Roethzeim, Richard R; Shibata, David; Meade, Cathy D; Gwede, Clement K
2016-11-15
Intervention studies among individuals in diverse community settings are needed to reduce health disparities in colorectal cancer (CRC) screening and mortality rates. The current study compared the efficacy of 2 intervention conditions promoting CRC screening among black individuals. Black individuals ages 50 to 75 years (N = 330) were recruited in community settings in 4 Tampa Bay counties. After obtaining consent and conducting a baseline interview to assess sociodemographic and health-related variables, participants received either a culturally targeted CRC photonovella booklet plus a fecal immunochemical test (FIT) kit or a standard CRC screening brochure plus an FIT kit. The primary outcome was FIT kit screening uptake. FIT screening uptake at 6 months was 86.7% overall (90.3% in the brochure group and 81.9% in the photonovella group). Controlling for baseline between-group differences, there was no influence of intervention on FIT kit uptake (P = .756). Significant predictors of not returning an FIT kit included being unable to work (P = .010), having higher religious belief scores (P = .015), and living farther from the cancer center (P = .015). Providing FIT kits and educational print materials to black individuals in community settings resulted in high rates of CRC screening. The study also identified subgroups of participants who were less likely to return an FIT kit and provides insight for future interventions. Cancer 2016;122:3288-3296. © 2016 American Cancer Society. © 2016 American Cancer Society.
Symonds, Erin L; Osborne, Joanne M; Cole, Stephen R; Bampton, Peter A; Fraser, Robert J L; Young, Graeme P
2015-12-01
Positive rates in faecal immunochemical test (FIT)-based colorectal cancer screening programmes vary, suggesting that differences between programmes may affect test results. We examined whether demographic, pathological, behavioural, and environmental factors affected haemoglobin concentration and positive rates where samples are mailed. A retrospective cohort study; 34,298 collection devices were sent, over five years, to screening invitees (median age 60.6). Participant demographics, temperature on sample postage day, and previous screening were recorded. Outcomes from colonoscopy performed within a year following FIT were collected. Multivariate logistic regression identified significant predictors of test positivity. Higher positive rate was independently associated with male gender, older age, lower socioeconomic status, and distally located neoplasia, and negatively associated with previous screening (p < 0.05). Older males had higher faecal haemoglobin concentrations and were less likely to have a false positive result at colonoscopy (p < 0.05). High temperature on the sample postage day was associated with reduced haemoglobin concentration and positivity rate (26-35℃: Odds ratio 0.78, 95% confidence interval 0.66-0.93), but was not associated with missed significant neoplasia at colonoscopy (p > 0.05). Haemoglobin concentrations, and therefore FIT positivity, were affected by factors that vary between screening programmes. Participant demographics and high temperature at postage had significant effects. The impact of temperature could be reduced by seasonal scheduling of invitations. The importance of screening, and following up positive test results, particularly in older males, should be promoted. © The Author(s) 2015.
Cubiella, Joaquín; Castells, Antoni; Andreu, Montserrat; Bujanda, Luis; Carballo, Fernando; Jover, Rodrigo; Lanas, Ángel; Morillas, Juan Diego; Salas, Dolores; Quintero, Enrique
2017-03-01
The adenoma detection rate (ADR) is the main quality indicator of colonoscopy. The ADR recommended in fecal immunochemical testing (FIT)-based colorectal cancer screening programs is unknown. Using the COLONPREV (NCT00906997) study dataset, we performed a post-hoc analysis to determine if there was a correlation between the ADR in primary and work-up colonoscopy, and the equivalent figure to the minimal 20% ADR recommended. Colonoscopy was performed in 5722 individuals: 5059 as primary strategy and 663 after a positive FIT result (OC-Sensor™; cut-off level 15 µg/g of feces). We developed a predictive model based on a multivariable lineal regression analysis including confounding variables. The median ADR was 31% (range, 14%-51%) in the colonoscopy group and 55% (range, 21%-83%) in the FIT group. There was a positive correlation in the ADR between primary and work-up colonoscopy (Pearson's coefficient 0.716; p < 0.001). ADR in the FIT group was independently related to ADR in the colonoscopy group: regression coefficient for colonoscopy ADR, 0.71 ( p = 0.009); sex, 0.09 ( p = 0.09); age, 0.3 ( p = 0.5); and region 0.00 ( p = 0.9). The equivalent figure to the 20% ADR was 45% (95% confidence interval, 35%-56%). ADR in primary and work-up colonoscopy of a FIT-positive result are positively and significantly correlated.
Castells, Antoni; Andreu, Montserrat; Bujanda, Luis; Carballo, Fernando; Jover, Rodrigo; Lanas, Ángel; Morillas, Juan Diego; Salas, Dolores; Quintero, Enrique
2016-01-01
Background The adenoma detection rate (ADR) is the main quality indicator of colonoscopy. The ADR recommended in fecal immunochemical testing (FIT)-based colorectal cancer screening programs is unknown. Methods Using the COLONPREV (NCT00906997) study dataset, we performed a post-hoc analysis to determine if there was a correlation between the ADR in primary and work-up colonoscopy, and the equivalent figure to the minimal 20% ADR recommended. Colonoscopy was performed in 5722 individuals: 5059 as primary strategy and 663 after a positive FIT result (OC-Sensor™; cut-off level 15 µg/g of feces). We developed a predictive model based on a multivariable lineal regression analysis including confounding variables. Results The median ADR was 31% (range, 14%–51%) in the colonoscopy group and 55% (range, 21%–83%) in the FIT group. There was a positive correlation in the ADR between primary and work-up colonoscopy (Pearson’s coefficient 0.716; p < 0.001). ADR in the FIT group was independently related to ADR in the colonoscopy group: regression coefficient for colonoscopy ADR, 0.71 (p = 0.009); sex, 0.09 (p = 0.09); age, 0.3 (p = 0.5); and region 0.00 (p = 0.9). The equivalent figure to the 20% ADR was 45% (95% confidence interval, 35%–56%). Conclusions ADR in primary and work-up colonoscopy of a FIT-positive result are positively and significantly correlated. PMID:28344793
Sapir, A; Shalev, A Hariton; Skalka, N; Bronshtein, A; Altstein, M
2013-03-01
Two approaches for monitoring atenolol (ATL) were applied: an immunochemical assay and a competitive-binding assay, based on the interaction between ATL and its target receptor, β1 adrenergic receptor (β1AR). Polyclonal antibodies (Abs) for ATL were generated, and a highly specific microplate immunochemical assay, that is, an enzyme-linked immunosorbent assay (ELISA), for its detection was developed. The ATL ELISA exhibited I50 and limit of detection (I20) values of 0.15 ± 0.048 and 0.032 ± 0.016 ng/ml, respectively, and the Abs did not cross-react with any of the tested beta-blocker drugs. Furthermore, a human β1AR (h-β1AR) was stably expressed in Spodoptera frugiperda cells (Sf9). The receptor was employed to develop a competitive-binding assay that monitored binding of ATL in the presence of isoproteranol by quantification of secondary messenger, cyclic adenosine monophosphate (cAMP), levels in the transfected cells. The assay showed that the recombinant h-β1AR was functional, could bind the agonistic ligand isoproterenol as well as the antagonist ATL, as indicated by a dose-dependent elevation of cAMP in the presence of isoproteranol, and decrease after ATL addition. The highly efficient and sensitive ELISA and the receptor assay represent two methods suitable for efficient and cost-effective large-scale, high-throughput monitoring of ATL in environmental, agricultural, and biological samples. Copyright © 2012 SETAC.
Quality, microstructure, biochemical and immunochemical characteristics of hypoallergenic pasta.
Susanna, S; Prabhasankar, P
2012-08-01
Celiac disease is an immune-mediated enteropathy, characterized by lifelong intolerance to gluten in genetically susceptible individuals. This study aims to develop hypoallergenic pasta using blends of Triticum durum semolina, 40% of other non-wheat flours and additives. Formulated pasta samples were evaluated for product quality characteristics and also subjected to biochemical analysis. Results showed that cooking loss ranged from 6.9% to 7.4%, which were within the acceptable range of 8%. Color change was low and in vitro protein digestibility of the pasta was found to be insignificant. Pasting characteristics of the hypoallergenic flour showed the increased peak viscosity and decreased gelatinization temperature. The scanning electron microscopy results demonstrated less-affected microstructure of gluten network. Texture profile analysis and descriptive sensory analysis revealed that optimized hypoallergenic pasta with xanthan gum as additive was acceptable and comparable with control. SDS-PAGE pattern showed distinct protein profile and decreased intensity, which was supported by Dot-Blot. In conclusion, the hypoallergenic pasta prepared by replacing T durum flour by 40% of other non-gluten flours could be useful for celiac patients because of its low antigenic activity.
Holec-Gąsior, Lucyna; Ferra, Bartłomiej; Czechowska, Justyna; Serdiuk, Illia E; Krzymiński, Karol
2018-05-01
Toxoplasma gondii infection is one of the most common human zoonosis. Laboratory diagnosis of this disease is mainly based on the results of serological methods detecting specific antibodies in the patient's sera. In this study we aimed to evaluate the performance of a chemiluminescence immunoassay (CLIA) based on the use of a novel immunochemical reagent in the form of the conjugate of original acridinium label (AL) attached to secondary antibody (IgG-AL) and SAG2-GRA1-ROP1 L chimeric antigen for T. gondii specific antibodies detection. The CLIA test was compared with conventional ELISA, which was based on the same recombinant antigen and differed only in terms of the detection methodology of immune complexes. The new CLIA assay proved to be more sensitive and better differentiated sera of patients with T. gondii infection from sera of healthy individuals, being a promising alternative to more labor, cost-demanding and less versatile ELISA as screening test in toxoplasmosis diagnostics. Copyright © 2018 Elsevier Inc. All rights reserved.
Multicentric epitheliotropic T-cell lymphoma in an African hedgehog (Atelerix albiventris).
Chung, Tae-Ho; Kim, Hyo-Jin; Choi, Ul-Soo
2014-12-01
A 2-year-old female African hedgehog was presented with a 5-month history of pruritus, and diffuse spine and hair loss. A dermatologic examination revealed erythema, excoriation, scales, and crusting affecting the face, flanks, forelimbs, hindlimbs, and dorsal and ventral abdomen. Fine-needle aspiration was performed and skin biopsies were taken from several lesions for cytologic and histologic evaluation. The aspirates yielded smears characterized by a monomorphic population of medium-sized to large lymphocytes with scant to moderate amounts of clear to moderately basophilic cytoplasm and distinct nucleoli along with a low number of cytoplasmic fragments. On histopathologic examination, there were dense dermal lymphoid infiltrates invading the dermis and a monomorphic population of round cells that had infiltrated the overlying epidermis. Epitheliotropic cutaneous lymphoma was diagnosed based on morphologic features. Additional immunochemical analysis using anti-CD3 and anti-CD79a antibodies revealed strong CD3 expression by the tumor cells, which confirmed epitheliotropic cutaneous T-cell lymphoma. This is the first description of a multicentric pattern of epitheliotropic cutaneous T-cell lymphoma in an African hedgehog. © 2014 American Society for Veterinary Clinical Pathology.
Monoclonal antibodies for the separate detection of halodeoxyuridines and method for their use
Vanderlaan, M.; Watkins, B.E.; Stanker, L.H.
1991-10-01
Monoclonal antibodies are described which have specific affinities for halogenated nucleoside analogs and are preferentially selective for one particular halogen. Such antibodies, when incorporated into immunochemical reagents, may be used to identify and independently quantify the cell division character of more than one population or subpopulation in flow cytometric measurements. Independent assessment of division activity in cell sub-populations facilitates selection of appropriate time and dose for administration of anti-proliferative agents. The hybridomas which secrete halogen selective antibodies and the method of making them are described. 14 figures.
Monoclonal antibodies for the separate detection of halodeoxyuridines and method for their use
Vanderlaan, Martin; Watkins, Bruce E.; Stanker, Larry H.
1991-01-01
Monoclonal antibodies are described which have specific affinities for halogenated nucleoside analogs and are preferentially selective for one particular halogen. Such antibodies, when incorporated into immunochemical reagents, may be used to identify and independently quantify the cell division character of more than one population or subpopulation in flow cytometric measurements. Independent assessment of division activity in cell sub-populations facilitates selection of appropriate time and dose for administration of anti-proliferative agents. The hybridomas which secrete halogen selective antibodies and the method of making them are described.
1993-07-01
be a very effective alkylating agent for bases in DNA. Even in blood, with a variety of reactive sites, I out of 124 guanine bases was alkylated to...required for effective competition in the ELISA test, although it contained at least as many adducts as the single-stranded DNA. This difference is...competitor. 203 Figure 92: The effect of the concentration of mustard gas to which single-stranded calf-thymus DNA had been exposed on the 50% inhibition
1991-12-01
radioactivity. Mustard gas appeared to be a very effective alkylating agent for. bases in DNA. Even in blood, with a variety of reactive sites, 1 out of 124...single-stranded material is required for effective competition in the ELISA test. although it contained at least as many adducts as the single-stranded DNA...DNA isolated from human white blood cells as competitor. 203 Figure 92: The effect of the concentration of mustard gas to which single-stranded calf
Prieto-Torres, Lucía; Alegría-Landa, Victoria; Llanos, Concepción; Córdoba, Alicia; Kutzner, Heinz; Requena, Luis
2017-05-01
Divergent differentiation or metaplastic change is a rare feature exhibited occasionally in malignant melanoma (MM), which is characterized by the development of morphologically, immunochemically, and/or ultrastructurally nonmelanocytic cells within the tumor. Smooth muscle differentiation in MM is an exceedingly rare phenomenon reported only in a few cases in the literature. We report the case of a 69-year-old woman who presented with a pure dermal amelanotic MM with smooth muscle cell differentiation and an area of rhabdoid morphology, which made the accurate histopathologic diagnostic of MM challenging.
42 CFR 431.424 - Evaluation requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... evaluations. Demonstration evaluations will include the following: (1) Quantitative research methods. (i... of appropriate evaluation strategies (including experimental and other quantitative and qualitative... demonstration. (ii) CMS will consider alternative evaluation designs when quantitative designs are technically...
42 CFR 431.424 - Evaluation requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... evaluations. Demonstration evaluations will include the following: (1) Quantitative research methods. (i... of appropriate evaluation strategies (including experimental and other quantitative and qualitative... demonstration. (ii) CMS will consider alternative evaluation designs when quantitative designs are technically...
42 CFR 431.424 - Evaluation requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... evaluations. Demonstration evaluations will include the following: (1) Quantitative research methods. (i... of appropriate evaluation strategies (including experimental and other quantitative and qualitative... demonstration. (ii) CMS will consider alternative evaluation designs when quantitative designs are technically...
Cha, Jae Myung; Lee, Joung Il; Joo, Kwang Ro; Shin, Hyun Phil; Park, Jae Jun
2011-11-01
Colorectal cancer (CRC) screening with a fecal immunochemical test (FIT) reduces CRC mortality; however, the acceptance rate of a colonoscopy in patients with a positive FIT was not high. The aim of this study was therefore to determine whether a telephone reminder call could increase the acceptance rate of colonoscopy in patients with a positive FIT. We performed FITs for asymptomatic participants aged 50 years or older. For patients with a positive FIT, a colonoscopy was recommended via mailing notification only (control group) or via a telephone reminder call after mailing notification (intervention group). The calls informed patients about the significance of a positive FIT and encouraged a colonoscopy following positive FITs. The FIT results were positive in 90 of 8,318 patients who received FITs. Fifty patients were advised to receive colonoscopy via mailing notification only, and 40 patients were advised via both a telephone reminder call and a mailing notification. The acceptance rate of colonoscopy was significantly higher in the intervention group than in the control group (p = 0.038). The lesion-detection rate for an advanced neoplasia was also significantly higher in the intervention group than in the control group (p = 0.046). According to multivariate logistic regression analysis, a telephone reminder was a significant determinant of colonoscopy acceptance in patients with a positive FIT (OR 4.33; 95% CI, 1.19-15.75; p = 0.026). Telephone reminder calls in addition to mailing notification improved the acceptance rate of colonoscopy in patients with a positive FIT.
Are Hemorrhoids Associated with False-Positive Fecal Immunochemical Test Results?
Kim, Nam Hee; Park, Jung Ho; Park, Dong Il; Sohn, Chong Il; Choi, Kyuyong; Jung, Yoon Suk
2017-01-01
False-positive (FP) results of fecal immunochemical tests (FITs) conducted in colorectal cancer (CRC) screening could lead to performing unnecessary colonoscopies. Hemorrhoids are a possible cause of FP FIT results; however, studies on this topic are extremely rare. We investigated whether hemorrhoids are associated with FP FIT results. A retrospective study was conducted at a university hospital in Korea from June 2013 to May 2015. Of the 34547 individuals who underwent FITs, 3946 aged ≥50 years who underwent colonoscopies were analyzed. Logistic regression analysis was performed to determine factors associated with FP FIT results. Among 3946 participants, 704 (17.8%) showed positive FIT results and 1303 (33.0%) had hemorrhoids. Of the 704 participants with positive FIT results, 165 had advanced colorectal neoplasia (ACRN) and 539 had no ACRN (FP results). Of the 1303 participants with hemorrhoids, 291 showed FP results, of whom 81 showed FP results because of hemorrhoids only. Participants with hemorrhoids had a higher rate of FP results than those without hemorrhoids (291/1176, 24.7% vs. 248/2361, 10.5%; p<0.001). Additionally, the participants with hemorrhoids as the only abnormality had a higher rate of FP results than those experiencing no such abnormalities (81/531, 15.3% vs. 38/1173, 3.2%; p<0.001). In multivariate analysis, the presence of hemorrhoids was identified as an independent predictor of FP results (adjusted odds ratio, 2.76; 95% confidence interval, 2.24-3.40; p<0.001). Hemorrhoids are significantly associated with FP FIT results. Their presence seemed to be a non-negligible contributor of FP results in FIT-based CRC screening programs.
van Turenhout, Sietze T; Oort, Frank A; Terhaar sive Droste, Jochim S; Coupé, Veerle M H; van der Hulst, Rene W; Loffeld, Ruud J; Scholten, Pieter; Depla, Annekatrien C T M; Bouman, Anneke A; Meijer, Gerrit A; Mulder, Chris J J; van Rossum, Leo G M
2012-07-01
Colorectal cancer screening by fecal immunochemical tests (FITs) is hampered by frequent false-positive (FP) results and thereby the risk of complications and strain on colonoscopy capacity. Hemorrhoids might be a plausible cause of FP results. To determine the contribution of hemorrhoids to the frequency of FP FIT results. Retrospective analysis from prospective cohort study. Five large teaching hospitals, including 1 academic hospital. All subjects scheduled for elective colonoscopy. FIT before bowel preparation. Frequency of FP FIT results in subjects with hemorrhoids as the only relevant abnormality compared with FP FIT results in subjects with no relevant abnormalities. Logistic regression analysis to determine colonic abnormalities influencing FP results. In 2855 patients, 434 had positive FIT results: 213 had advanced neoplasia and 221 had FP results. In 9 individuals (4.1%; 95% CI, 1.4-6.8) with an FP FIT result, hemorrhoids were the only abnormality. In univariate unadjusted analysis, subjects with hemorrhoids as the only abnormality did not have more positive results (9/134; 6.7%) compared with subjects without any abnormalities (43/886; 4.9%; P = .396). Logistic regression identified hemorrhoids, nonadvanced polyps, and a group of miscellaneous abnormalities, all significantly influencing false positivity. Of 1000 subjects with hemorrhoids, 67 would have FP results, of whom 18 would have FP results because of hemorrhoids only. Potential underreporting of hemorrhoids; high-risk individuals. Hemorrhoids in individuals participating in colorectal cancer screening will probably not lead to a substantial number of false-positive test results. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Ibáñez-Sanz, Gemma; Garcia, Montse; Rodríguez-Moranta, Francisco; Binefa, Gemma; Gómez-Matas, Javier; Domènech, Xènia; Vidal, Carmen; Soriano, Antonio; Moreno, Víctor
2016-10-01
The most common side effect in population screening programmes is a false-positive result which leads to unnecessary risks and costs. To identify factors associated with false-positive results in a colorectal cancer screening programme with the faecal immunochemical test (FIT). Cross-sectional study of 472 participants with a positive FIT who underwent colonoscopy for confirmation of diagnosis between 2013 and 2014. A false-positive result was defined as having a positive FIT (≥20μg haemoglobin per gram of faeces) and follow-up colonoscopy without intermediate/high-risk lesions or cancer. Women showed a two-fold increased likelihood of a false-positive result compared with men (adjusted OR, 2.3; 95%CI, 1.5-3.4), but no female-specific factor was identified. The other variables associated with a false-positive result were successive screening (adjusted OR, 1.5; 95%CI, 1.0-2.2), anal disorders (adjusted OR, 3.1; 95%CI, 2.1-4.5) and the use of proton pump inhibitors (adjusted OR, 1.8; 95%CI, 1.1-2.9). Successive screening and proton pump inhibitor use were associated with FP in men. None of the other drugs were related to a false-positive FIT. Concurrent use of proton pump inhibitors at the time of FIT might increase the likelihood of a false-positive result. Further investigation is needed to determine whether discontinuing them could decrease the false-positive rate. Copyright © 2016 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Parente, Fabrizio; Vailati, Cristian; Boemo, Cinzia; Bonoldi, Emanuela; Ardizzoia, Antonio; Ilardo, Antonina; Tortorella, Franco; Cereda, Danilo; Cremaschini, Marco; Moretti, Roberto
2015-01-01
Colorectal cancer screening may reduce disease-related mortality by early-stage detection of cancers. To study the effect of a single immunochemical faecal occult blood test (i-FOBt) screening round on reduction in colorectal cancer-related-mortality among average risk subjects. Comparison of 5-year mortality rates in 3 cohorts from a Northern Italian province: (1) colorectal cancers detected at the 1st biennial round of a mass-screening programme targeting 50-69 years old subjects, (2) non-screening cancers symptomatically diagnosed during the same time period, and (3) cancers detected in the pre-screening biennium. Multivariate analyses were performed with the Cox regression model including tumour node metastasis (TNM) stage at diagnosis, anatomical distribution of cancers, age at diagnosis, gender and patient group. Kaplan-Meyer survival estimates and log-rank test for equality of survivor functions were calculated. Stage distribution significantly differed between screening and non-screening colorectal cancers: 73% of screen-detected colorectal cancers were stages I and II versus 43% and 40% of non-screening and pre-screening colorectal cancers. Cumulative 5-year mortality rate was significantly lower in screening compared to non-screening or pre-screening colorectal cancers patients (19% versus 37% and 41%, p < 0.001). Colorectal cancers were detected at earlier stages in i-FOBT-positive subjects in comparison with non-screening patients; colorectal cancers found at screening had a significantly improved 5-year survival. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
The cost-effectiveness of screening for colorectal cancer.
Telford, Jennifer J; Levy, Adrian R; Sambrook, Jennifer C; Zou, Denise; Enns, Robert A
2010-09-07
Published decision analyses show that screening for colorectal cancer is cost-effective. However, because of the number of tests available, the optimal screening strategy in Canada is unknown. We estimated the incremental cost-effectiveness of 10 strategies for colorectal cancer screening, as well as no screening, incorporating quality of life, noncompliance and data on the costs and benefits of chemotherapy. We used a probabilistic Markov model to estimate the costs and quality-adjusted life expectancy of 50-year-old average-risk Canadians without screening and with screening by each test. We populated the model with data from the published literature. We calculated costs from the perspective of a third-party payer, with inflation to 2007 Canadian dollars. Of the 10 strategies considered, we focused on three tests currently being used for population screening in some Canadian provinces: low-sensitivity guaiac fecal occult blood test, performed annually; fecal immunochemical test, performed annually; and colonoscopy, performed every 10 years. These strategies reduced the incidence of colorectal cancer by 44%, 65% and 81%, and mortality by 55%, 74% and 83%, respectively, compared with no screening. These strategies generated incremental cost-effectiveness ratios of $9159, $611 and $6133 per quality-adjusted life year, respectively. The findings were robust to probabilistic sensitivity analysis. Colonoscopy every 10 years yielded the greatest net health benefit. Screening for colorectal cancer is cost-effective over conventional levels of willingness to pay. Annual high-sensitivity fecal occult blood testing, such as a fecal immunochemical test, or colonoscopy every 10 years offer the best value for the money in Canada.
Lehmann, Karin; Hause, Bettina; Altmann, Dorit; Köck, Margret
2001-01-01
We have studied the subcellular localization of the acid S-like ribonuclease (RNase) LX in tomato (Lycopersicon esculentum Mill.) cells using a combination of biochemical and immunological methods. It was found that the enzyme, unexpectedly excluded from highly purified vacuoles, accumulates in the endoplasmic reticulum. The evidence that RNase LX is a resident of the endoplasmic reticulum (ER) is supported by an independent approach showing that the C-terminal peptide HDEF of RNase LX acts as an alternative ER retention signal in plants. For functional testing, the cellular distribution of chimeric protein constructs based on a marker protein, Brazil nut (Bertholletia excelsa) 2S albumin, was analyzed immunochemically in transgenic tobacco (Nicotiana tabacum) plants. Here, we report that the peptide motif is necessary and sufficient to accumulate 2S albumin constructs of both vacuolar and extracellular final destinations in the ER. We have shown immunochemically that RNase LX is specifically expressed during endosperm mobilization and leaf and flower senescence. Using immunofluorescence, RNase LX protein was detected in immature tracheary elements, suggesting a function in xylem differentiation. These results support a physiological function of RNase LX in selective cell death processes that are also thought to involve programmed cell death. It is assumed that RNase LX accumulates in an ER-derived compartment and is released by membrane disruption into the cytoplasma of those cells that are intended to undergo autolysis. These processes are accompanied by degradation of cellular components supporting a metabolic recycling function of the intracellular RNase LX. PMID:11598219
Jung, Yoon Suk; Park, Chan Hyuk; Kim, Nam Hee; Park, Jung Ho; Park, Dong Il; Sohn, Chong Il
2018-01-01
The fecal immunochemical test (FIT) has low sensitivity for detecting advanced colorectal neoplasia (ACRN); thus, a considerable portion of FIT-negative persons may have ACRN. We aimed to develop a risk-scoring model for predicting ACRN in FIT-negative persons. We reviewed the records of participants aged ≥40 years who underwent a colonoscopy and FIT during a health check-up. We developed a risk-scoring model for predicting ACRN in FIT-negative persons. Of 11,873 FIT-negative participants, 255 (2.1%) had ACRN. On the basis of the multivariable logistic regression model, point scores were assigned as follows among FIT-negative persons: age (per year from 40 years old), 1 point; current smoker, 10 points; overweight, 5 points; obese, 7 points; hypertension, 6 points; old cerebrovascular attack (CVA), 15 points. Although the proportion of ACRN in FIT-negative persons increased as risk scores increased (from 0.6% in the group with 0-4 points to 8.1% in the group with 35-39 points), it was significantly lower than that in FIT-positive persons (14.9%). However, there was no statistical difference between the proportion of ACRN in FIT-negative persons with ≥40 points and in FIT-positive persons (10.5% vs. 14.9%, P = 0.321). FIT-negative persons may need to undergo screening colonoscopy if they clinically have a high risk of ACRN. The scoring model based on age, smoking habits, overweight or obesity, hypertension, and old CVA may be useful in selecting and prioritizing FIT-negative persons for screening colonoscopy.
Clarke, Nicholas; Gallagher, Pamela; Kearney, Patricia M; McNamara, Deirdre; Sharp, Linda
2016-12-01
Faecal immunochemical tests (FITs) are increasingly being used in population-based colorectal cancer-screening programmes. Uptake of FIT is lower in men than women; however, the reasons for this are not well understood. We aimed to explore gender differences in influences on decisions to participate in FIT screening. This is a qualitative study using in-depth face-to-face interviews of four groups of screening invitees (male and female screening users and male and female screening non-users), purposively sampled from the database of a population-based FIT screening programme. Recruitment continued until saturation was reached. Interviews were audio recorded and transcribed verbatim. Thematic analysis using the framework approach was employed with the theoretical domains framework guiding analysis. Forty-seven screening invitees were interviewed. Six theoretical domains influenced screening uptake: 'environmental context and resources', 'beliefs about capabilities', 'beliefs about consequences', 'emotions', 'social influences' and 'knowledge'. Male non-users were often fatalistic, less knowledgeable and misinformed about cancer and FIT screening compared with other groups. Female non-users expressed negative attitudes, beliefs and emotions towards FIT screening, cancer, social influences and the medical profession and were over-confident about their health. Negative attitudes and emotions to screening dominated non-user decision-making but differed by gender. Opportunities to improve uptake in men and women exist. Greater national discussions on the benefits of FIT screening, and development of screening materials tackling negative attitudes and beliefs while recognising male/female differences, may improve screening uptake. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Ammonia-induced brain swelling and neurotoxicity in an organotypic slice model
Back, Adam; Tupper, Kelsey Y.; Bai, Tao; Chiranand, Paulpoj; Goldenberg, Fernando D.; Frank, Jeffrey I.; Brorson, James R.
2013-01-01
Objectives Acute liver failure produces cerebral dysfunction and edema, mediated in part by elevated ammonia concentrations, often leading to coma and death. The pathophysiology of cerebral edema in acute liver failure is incompletely understood. In vitro models of the cerebral effects of acute liver failure have predominately consisted of dissociated astrocyte cultures or acute brain slices. We describe a stable long-term culture model incorporating both neural and glial elements in a three-dimensional tissue structure offering significant advantages to the study of astrocytic-neuronal interactions in the pathophysiology of cerebral edema and dysfunction in acute liver failure. Methods We utilized chronic organotypic slice cultures from mouse forebrain, applying ammonium acetate in iso-osmolar fashion for 72 hours. Imaging of slice thickness to assess for tissue swelling was accomplished in living slices with optical coherence tomography, and confocal microscopy of fluorescence immunochemical and histochemical staining served to assess astrocyte and neuronal numbers, morphology, and volume in the fixed brain slices. Results Ammonia exposure at 1–10 mM produced swelling of immunochemically-identified astrocytes, and at 10 mM resulted in macroscopic tissue swelling, with slice thickness increasing by about 30%. Astrocytes were unchanged in number. In contrast, 10 mM ammonia treatment severely disrupted neuronal morphology and reduced neuronal survival at 72 hours by one-half. Discussion Elevated ammonia produces astrocytic swelling, tissue swelling, and neuronal toxicity in cerebral tissues. Ammonia-treated organotypic brain slice cultures provide an in vitro model of cerebral effects of conditions relevant to acute liver failure, applicable to pathophysiological investigations. PMID:22196764
Wang, Jiayan Linda; Acevedo, Nazia; Sadler, Georgia Robins
2017-06-23
There are unaesthetic aspects in teaching people about the early detection of colorectal cancer using the fecal immunochemical test. Comics were seen as a way to overcome those unaesthetic aspects. This study used the Asian grocery store-based cancer education venue to pilot-test the clarity, cultural acceptability, and alignment of five colorectal cancer education comics intended for publication in Asian American and Pacific Islander (API) community newspapers. After developing the colorectal cancer education comics, API students asked shoppers to review a comic from their collection and provide feedback on how to make the comic clearer and more culturally pertinent to API readers. To evaluate viewers' responses, the students gathered such unobtrusive data as: (1) how many of the predetermined salient information points were discussed as the student educators interacted with shoppers and (2) how many comics the shoppers were willing to review. Shoppers were also asked to evaluate how effective the comics would be at motivating colorectal cancer screening among APIs. The students were able to cover all of the salient information points with the first comic. As evidence of the comics' capacity to engage shoppers' interest, shoppers willingly evaluated all five comics. Using multiple comics enabled the educators to repeatedly address the four salient colorectal cancer information points. Thus, the comics helped student educators to overcome the unesthetic elements of colorectal cancer discussions, while enabling them to engage shoppers in animated discussions, for far more time than with their conventional didactic educational methods.
The role of quantitative safety evaluation in regulatory decision making of drugs.
Chakravarty, Aloka G; Izem, Rima; Keeton, Stephine; Kim, Clara Y; Levenson, Mark S; Soukup, Mat
2016-01-01
Evaluation of safety is a critical component of drug review at the US Food and Drug Administration (FDA). Statisticians are playing an increasingly visible role in quantitative safety evaluation and regulatory decision-making. This article reviews the history and the recent events relating to quantitative drug safety evaluation at the FDA. The article then focuses on five active areas of quantitative drug safety evaluation and the role Division of Biometrics VII (DBVII) plays in these areas, namely meta-analysis for safety evaluation, large safety outcome trials, post-marketing requirements (PMRs), the Sentinel Initiative, and the evaluation of risk from extended/long-acting opioids. This article will focus chiefly on developments related to quantitative drug safety evaluation and not on the many additional developments in drug safety in general.
NASA Technical Reports Server (NTRS)
1982-01-01
Ventrex Laboratories, Inc. develops, manufactures and markets a line of medical diagnostic assays based on biochemical techniques, in particular immunochemical techniques. Their products are sold worldwide to hospitals and medical laboratories for use in testing blood samples and other biological fluids. Analysis of a patient's body fluids, compared with normal values, aids a physician in confirming or otherwise diagnosing a suspected disease condition. NERAC's rapid information retrieval has provided Ventrex invaluable up-to-date information, and has permitted large scale savings. NERAC's service was particularly important in the development of a new product in the company's Ventre/Sep line, which is used in radioimmunoassays.
Brion, F; Rogerieux, F; Noury, P; Migeon, B; Flammarion, P; Thybaud, E; Porcher, J M
2000-01-14
A two-step purification protocol was developed to purify rainbow trout (Oncorhynchus mykiss) vitellogenin (Vtg) and was successfully applied to Vtg of chub (Leuciscus cephalus) and gudgeon (Gobio gobio). Capture and intermediate purification were performed by anion-exchange chromatography on a Resource Q column and a polishing step was performed by gel permeation chromatography on Superdex 200 column. This method is a rapid two-step purification procedure that gave a pure solution of Vtg as assessed by silver staining electrophoresis and immunochemical characterisation.
van Hees, Frank; Zauber, Ann G.; van Veldhuizen, Harriët; Heijnen, Marie-Louise A.; Penning, Corine; de Koning, Harry J.; van Ballegooijen, Marjolein; Lansdorp-Vogelaar, Iris
2015-01-01
In May 2011, the Dutch government decided to implement a national programme for colorectal cancer (CRC) screening using biennial faecal immunochemical test (FIT) screening between ages 55 and 75.[1] Decision modelling played an important role in informing this decision, as well as in the planning and implementation of the programme afterwards. In this overview, we illustrate the value of models in informing resource allocation in CRC screening, using the role that decision modelling has played in the Dutch CRC screening programme as an example. PMID:26063755
Parathyroid hormone - Secretion and metabolism in vivo.
NASA Technical Reports Server (NTRS)
Habener, J. F.; Powell, D.; Murray, T. M.; Mayer, G. P.; Potts, J. T., Jr.
1971-01-01
Gel filtration and radioimmunoassay were used to determine the molecular size and immunochemical reactivity of parathyroid hormone present in gland extracts, in the general peripheral circulation, and in parathyroid effluent blood from patients with hyperparathyroidism, as well as from calves and from cattle. It was found that parathyroid hormone secreted from the parathyroids in man and cattle is at least as large as the molecule extracted from normal bovine glands. However, once secreted into the circulation the hormone is cleaved, and one or more fragments, immunologically, dissimilar to the originally secreted hormone, constitute the dominant form of circulating immunoreactive hormone.
Continuing evolution of in-vitro diagnostic instrumentation
NASA Astrophysics Data System (ADS)
Cohn, Gerald E.
2000-04-01
The synthesis of analytical instrumentation and analytical biochemistry technologies in modern in vitro diagnostic instrumentation continues to generate new systems with improved performance and expanded capability. Detection modalities have expanded to include multichip modes of fluorescence, scattering, luminescence and reflectance so as to accommodate increasingly sophisticated immunochemical and nucleic acid based reagent systems. The time line graph of system development now extends from the earliest automated clinical spectrophotometers through molecule recognition assays and biosensors to the new breakthroughs of biochip and DNA diagnostics. This brief review traces some of the major innovations in the evolution of system technologies and previews the conference program.
Bupropion interference with immunoassays for amphetamines and LSD.
Vidal, Christian; Skripuletz, Thomas
2007-06-01
A 50-year-old male patient suddenly had lost consciousness, although he had previously been healthy. On arrival at hospital seizures arose. The authors investigated a urine sample of the patient, and performed toxicological drug screening with immunochemical Cloned Enzyme Donor Immunoassay (CEDIA) assays. Positive findings for amphetamines and LSD could not be confirmed. Using gas chromatography/mass spectrometry (GC/MS), and liquid chromatography/mass spectrometry (LC/MS), the authors identified bupropion, a drug used to aid in smoking cessation, as the interfering compound, which may cause false-positive results for amphetamines and LSD using the CEDIA assays.
NASA Astrophysics Data System (ADS)
Gajos, Katarzyna; Angelopoulou, Michailia; Petrou, Panagiota; Awsiuk, Kamil; Kakabakos, Sotirios; Haasnoot, Willem; Bernasik, Andrzej; Rysz, Jakub; Marzec, Mateusz M.; Misiakos, Konstantinos; Raptis, Ioannis; Budkowski, Andrzej
2016-11-01
Time-of-flight secondary ion mass spectrometry (imaging, micro-analysis) has been employed to evaluate biofunctionalization of the sensing arm areas of Mach-Zehnder interferometers monolithically integrated on silicon chips for the immunochemical (competitive) detection of bovine κ-casein in goat milk. Biosensor surfaces are examined after: modification with (3-aminopropyl)triethoxysilane, application of multiple overlapping spots of κ-casein solutions, blocking with 100-times diluted goat milk, and reaction with monoclonal mouse anti-κ-casein antibodies in blocking solution. The areas spotted with κ-casein solutions of different concentrations are examined and optimum concentration providing homogeneous coverage is determined. Coverage of biosensor surfaces with biomolecules after each of the sequential steps employed in immunodetection is also evaluated with TOF-SIMS, supplemented by Atomic force microscopy and X-ray photoelectron spectroscopy. Uniform molecular distributions are observed on the sensing arm areas after spotting with optimum κ-casein concentration, blocking and immunoreaction. The corresponding biomolecular compositions are determined with a Principal Component Analysis that distinguished between protein amino acids and milk glycerides, as well as between amino acids characteristic for Mabs and κ-casein, respectively. Use of the optimum conditions (κ-casein concentration) for functionalization of chips with arrays of ten Mach-Zehnder interferometers provided on-chips assays with dramatically improved both intra-chip response repeatability and assay detection sensitivity.
Piette, Christine; Durand, Gérard; Bretagne, Jean-François; Faivre, Jean
2017-03-01
Compliance with colorectal cancer screening is critical to its effectiveness. The organisation of the mass screening programme in France has recently been modified with no evaluation of the consequences. To evaluate the impact of the way the screening test is delivered on compliance. During the first six months of the screening campaign (Ille-Vilaine, Brittany), general practitioners were asked to propose a faecal immunochemical test (FIT), OC-Sensor, to individuals at average risk for colorectal cancer (n=152,097). A subset of non-participants in the medical phase (n=13,071) was randomly chosen to receive a reminder that included the screening test or a simple postal reminder without the screening test. Compliance was 31% if the screening test was proposed during a medical consultation. In non-participants during the medical phase, it was 45% in those receiving both a reminder and the screening test and 28% amongst those receiving a simple reminder. An estimated overall participation rate of 54% can be expected if non-participants in the medical phase are sent a reminder together with the screening test. In France, a compliance rate above the minimum uptake rate of 45% recommended by European Union experts can be achieved if the FIT is mailed to non-participants after the medical free-offer phase. Copyright © 2016. Published by Elsevier Ltd.
Development and immunochemical evaluation of a novel chicken IgY antibody specific for KLK6.
Sotiropoulou, Georgia; Pampalakis, Georgios; Prosnikli, Evangelia; Evangelatos, Gregory P; Livaniou, Evangelia
2012-12-05
Human kallikrein-related peptidase 6 (KLK6) has been implicated in various types of cancer and in neurodegenerative and demyelinating diseases including multiple sclerosis. Further, anti-KLK6 antibodies attenuated disease manifestations in the mouse model of multiple sclerosis. Availability of specific antibodies against KLK6 is fundamental to the development of improved diagnostic and/or immunotherapeutic applications. Here, we exploited the enhanced immunogenicity of mammalian proteins in avian species to generate a polyclonal antibody against KLK6. Chicken were immunized with recombinant KLK6 and antibodies Y (IgYs) were purified from egg yolk with a simple procedure and evaluated for KLK6 detection by ELISA and Western blot using recombinant proteins and human cell lysates and supernatants. The anti-KLK6 Y polyclonal exhibited high affinity for KLK6 with a detection limit of 30 fmol. On the other hand, the widely used rabbit polyclonal antibody that was raised against the same recombinant KLK6 had a detection limit of 300 fmol. Moreover, the IgYs did not display any crossreactivity with recombinant KLKs or endogenous KLKs and other cellular proteins. Based on its high specificity and sensitivity the developed anti-KLK6 IgY is expected to aid the development of improved diagnostic tools for the detection of KLK6 in biological and clinical samples.
Development and immunochemical evaluation of a novel chicken IgY antibody specific for KLK6
2012-01-01
Background Human kallikrein-related peptidase 6 (KLK6) has been implicated in various types of cancer and in neurodegenerative and demyelinating diseases including multiple sclerosis. Further, anti-KLK6 antibodies attenuated disease manifestations in the mouse model of multiple sclerosis. Availability of specific antibodies against KLK6 is fundamental to the development of improved diagnostic and/or immunotherapeutic applications. Here, we exploited the enhanced immunogenicity of mammalian proteins in avian species to generate a polyclonal antibody against KLK6. Results Chicken were immunized with recombinant KLK6 and antibodies Y (IgYs) were purified from egg yolk with a simple procedure and evaluated for KLK6 detection by ELISA and Western blot using recombinant proteins and human cell lysates and supernatants. The anti-KLK6 Y polyclonal exhibited high affinity for KLK6 with a detection limit of 30 fmol. On the other hand, the widely used rabbit polyclonal antibody that was raised against the same recombinant KLK6 had a detection limit of 300 fmol. Moreover, the IgYs did not display any crossreactivity with recombinant KLKs or endogenous KLKs and other cellular proteins. Conclusions Based on its high specificity and sensitivity the developed anti-KLK6 IgY is expected to aid the development of improved diagnostic tools for the detection of KLK6 in biological and clinical samples. PMID:23216878
Krasuska, Urszula; Ciacka, Katarzyna; Dębska, Karolina; Bogatek, Renata; Gniazdowska, Agnieszka
2014-08-15
Deep dormancy of apple (Malus domestica Borkh.) embryos can be overcome by short-term pre-treatment with nitric oxide (NO) or hydrogen cyanide (HCN). Dormancy alleviation of embryos modulated by NO or HCN and the first step of germination depend on temporary increased production of reactive oxygen species (ROS). Direct oxidative attack on some amino acid residues or secondary reactions via reactive carbohydrates and lipids can lead to the formation of protein carbonyl derivatives. Protein carbonylation is a widely accepted covalent and irreversible modification resulting in inhibition or alteration of enzyme/protein activities. It also increases the susceptibility of proteins to proteolytic degradation. The aim of this work was to investigate protein carbonylation in germinating apple embryos, the dormancy of which was removed by pre-treatment with NO or HCN donors. It was performed using a quantitative spectrophotometric method, while patterns of carbonylated protein in embryo axes were analyzed by immunochemical techniques. The highest concentration of protein carbonyl groups was observed in dormant embryos. It declined in germinating embryos pre-treated with NO or HCN, suggesting elevated degradation of modified proteins during seedling formation. A decrease in the concentration of carbonylated proteins was accompanied by modification in proteolytic activity in germinating apple embryos. A strict correlation between the level of protein carbonyl groups and cotyledon growth and greening was detected. Moreover, direct in vitro carbonylation of BSA treated with NO or HCN donors was analyzed, showing action of both signaling molecules as protein oxidation agents. Copyright © 2014 Elsevier GmbH. All rights reserved.
Yeroslavsky, Gil; Girshevitz, Olga; Foster-Frey, Juli; Donovan, David M; Rahimipour, Shai
2015-01-27
Antibiotic resistance and the colonization of bacteria on surfaces, often as biofilms, prolong hospitalization periods, increase mortality, and are thus major concerns for health care providers. There is an urgent need for antimicrobial and antibiofilm surface treatments that are permanent, can eradicate both biofilms and planktonic pathogens over long periods of time, and do not select for resistant strains. In this study, we have demonstrated a simple, robust, and biocompatible method that utilizes the adhesive property of polydopamine (PDA) to covalently attach the antimicrobial enzyme lysostaphin (Lst) to a variety of surfaces to generate antibacterial and antibiofilm interfaces. The immobilization of the recombinant Lst onto PDA-coated surfaces was carried out under physiological conditions, most probably through the C-terminal His6-tag fragment of the enzyme, minimizing the losses of bioagent activity. The modified surfaces were extensively characterized by X-ray photoelectron spectroscopy and peak force quantitative nanomechanical mapping (PeakForce QNM) AFM-based method, and the presence of Lst on the surfaces was further confirmed immunochemically using anti-Lst antibody. We also found that, in contrast to the physically adsorbed Lst, the covalently attached Lst does not leach from the surfaces and maintains its endopeptidase activity to degrade the staphylococcal cell wall, avoiding most intracellular bacterial resistance mechanisms. Moreover, the Lst-coated surfaces kill hospital strains of Staphylococcus aureus in less than 15 min and prevent biofilm formation. This immobilization method should be applicable also to other proteins and enzymes that are recombinantly expressed to include the His6-tag fragment.
Gastric clearance of serum albumin in normal man and in certain gastroduodenal disorders
Brassinne, A.
1974-01-01
Serum albumin gastric loss was estimated from the measurement of non-dialysable radioactivity of the gastric juice after intravenous injection of radioiodinated serum albumin (RISA). Immunochemical quantitation of serum albumin was performed in some of the samples. In the control group, the mean gastric clearance of albumin was 1·71 ml per hour with a range of 0·41 to 4·41 ml per hour. This represented a gastric loss of 1·9 gram of albumin per day and 11% of the daily degradation of albumin. There was no significant change in the gastric albumin loss after stimulating the gastric secretion. No significant difference in the gastric albumin leakage was found between normal subjects and patients with gastric or duodenal ulcer. In pernicious anaemia albumin loss into the stomach was greater (mean: 3·72 ml per hour; SD 1·52 ml) than in the normal group and accounted for the greater albumin fractional catabolic rate. This fact had never been proved before. In both patients with giant rugae of the gastric mucosa the gastric clearance of serum albumin was also increased. It is concluded first that albumin is not secreted by the chief and parietal cells of the mucosa and probably passes through the gastric wall between the cells of the mucosa, perhaps during the exfoliation of the surface epithelial cells, and secondly that the stomach is one of the sites of serum albumin breakdown, a fact that supports the view that the gastrointestinal tract plays a major role in the catabolism of serum albumin. PMID:4210183
Yadirgi, G; Stickings, P; Rajagopal, S; Liu, Y; Sesardic, D
2017-12-01
Botulinum toxin type A is a causative agent of human botulism. Due to high toxicity and ease of production it is classified by the Centres for Disease Control and Prevention as a category A bioterrorism agent. The same serotype, BoNT/A, is also the most widely used in pharmaceutical preparations for treatment of a diverse range of neuromuscular disorders. Traditionally, animals are used to confirm the presence and activity of toxin and to establish neutralizing capabilities of countermeasures in toxin neutralization tests. Cell based assays for BoNT/A have been reported as the most viable alternative to animal models, since they are capable of reflecting all key steps (binding, translocation, internalization and cleavage of intracellular substrate) involved in toxin activity. In this paper we report preliminary development of a simple immunochemical method for specifically detecting BoNT/A cleaved intracellular substrate, SNAP-25, in cell lysates of neurons derived from mouse embryonic stem cells. The assay offers sensitivity of better than 0.1LD50/ml (3fM) which is not matched by other functional assays, including the mouse bioassay, and provides serotype specificity for quantitative detection of BoNT/A and anti-BoNT/A antitoxin. Subject to formal validation, the method described here could potentially be used as a substitute for the mouse bioassay to measure potency and consistency of therapeutic products. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Danilova, V M; Vynogradova, R P; Torkhova, S G
2016-01-01
The article is devoted to the inventive activity of the Department of Molecular Immunology of the Palladin Institute of Biochemistry of NAS of Ukraine in the context of the history of its inception, development and in the context of scholarly and organizational activities of Sergii Vasyl’ovych Komisarenko. This autumn marks 50th anniversary since young Sergii Komisarenko (now – Academician of NAS and NAMS of Ukraine, Dr. Biol. Sci., Professor) has joined the Palladin Institute of Biochemistry, has completed all stages of the academic carrier from PhD student to Head of the Institute. He is the first in Ukraine who started the new branch of research – molecular immunology, created a strong scientific school, which earned worldwide acclaim and made significant contribution to finding solutions to current problems in human health sciences. S.V. Komisarenko was among those, who were first in the USSR to use immunoenzyme and flow cytofluometric assays, hybridoma technology for producing monoclonal antibodies and immunochemical assay of proteins, which became the basis for development of highly sensitive and highly specific immunodiagnostic systems, which are of high necessity in medicine, veterinary, development of immunotechnologies, environment monitoring, etc. Under his leadership the Department has made a series of important discoveries and developments including relating to antitumour immunotoxins, effects of low dose radiation on the immune system of Chernobyl liquidators, immunochemical structure of neurotoxin apamine, cytochrom c, fibrinogen and fibrin molecules at different stages of polymerization, diphtheria toxin and its receptor, tuberculosis causing micobacterium, roles of protease-activated receptors (PARs) and nicotinic acetylcholine receptors of lymphocytes, nature of polyreactive immunoglobulins (PRIGs), among other important scientific contributions. S.V. Komisarenko and his colleagues also hold numerous (more than 80) author’s certificates and patents in Ukraine and USSR.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Toraya, Tetsuo; Kida, Tetsuo; Kuyama, Atsushi
Starfish oocytes are arrested at the prophase stage of the first meiotic division in the ovary and resume meiosis by the stimulus of 1-methyladenine (1-MeAde), the oocyte maturation-inducing hormone of starfish. Putative 1-MeAde receptors on the oocyte surface have been suggested, but not yet been biochemically characterized. Immunophotoaffinity labeling, i.e., photoaffinity labeling combined with immunochemical detection, was attempted to detect unknown 1-MeAde binders including putative maturation-inducing hormone receptors in starfish oocytes. When the oocyte crude membrane fraction or its Triton X-100/EDTA extract was incubated with N{sup 6}-[6-(5-azido-2-nitrobenzoyl)aminohexyl]carboxamidomethyl-1-methyladenine and then photo-irradiated, followed by western blotting with antibody that was raised againstmore » a 1-MeAde hapten, a single band with M{sub r} of 47.5 K was detected. The band was lost when extract was heated at 100 °C. A similar 47.5 K band was detected in the crude membrane fraction of testis as well. Upon labeling with whole cells, this band was detected in immature and maturing oocytes, but only faintly in mature oocytes. As judged from these results, this 1-MeAde binder might be a possible candidate of the starfish maturation-inducing hormone receptors. - Highlights: • Synthesis of photoaffinity labeling reagents for 1-methyladenine binders of starfish. • Immunochemical detection of photoaffinity-labeled 1-methyladenine binders. • Immunophotoaffinity labeling of a 47.5 K 1-methyladenine binder in oocytes and testis. • A possible candidate of oocyte maturation-inducing hormone receptors of starfish.« less
Oliveira, Isabela S; Cabral, Milena S; Jesus, Larissa S; Paraná, Raymundo; Atta, Ajax M; Sousa Atta, Maria Luiza B
2014-01-01
Hepatitis C virus (HCV) infects B-lymphocytes, provokes cellular dysfunction and causes lymphoproliferative diseases such as cryoglobulinemia and non-Hodgkin's B-cell lymphoma. In the present study, we investigated the serum levels of kappa and lambda free light chains (FLC) of immunoglobulins and the kappa/lambda FLC ratio in Brazilian patients with chronic HCV infection and cryoglobulinemia. We also analyzed the immunochemical composition of the cryoglobulins in these patients. Twenty-eight cryoglobulinemic HCV patients composed the target group, while 37 HCV patients without cryoglobulinemia were included as controls. The median levels of kappa and lambda FLC were higher in patients with cryoglobulinemia compared to controls (p=0.001 and p=0.003, respectively), but the kappa/lambda FLC ratio was similar in patients with and without cryoglobulinemia (p>0.05). The median FLC ratio was higher in HCV patients presenting with advanced fibrosis of the liver compared to HCV patients without fibrosis (p=0.004). Kappa and lambda FLC levels were strongly correlated with the IgA, IgG and IgM levels in the patients with cryoglobulinemia. In patients without cryoglobulinemia, the kappa FLC level was only correlated with the IgG level, whereas the lambda FLC were weakly correlated with the IgA, IgG and IgM levels. An immunochemical pattern of mixed cryoglobulins (MC), predominantly IgM, IgG, IgA and kappa light chain, was verified in these immune complexes. We concluded that HCV-infected patients presenting cryoglobulinemia have vigorous polyclonal B-lymphocyte activation due to chronic HCV infection and persistent immune stimulation. Copyright © 2014 Elsevier Editora Ltda. All rights reserved.
Are Hemorrhoids Associated with False-Positive Fecal Immunochemical Test Results?
Kim, Nam Hee; Park, Jung Ho; Park, Dong Il; Sohn, Chong Il; Choi, Kyuyong
2017-01-01
Purpose False-positive (FP) results of fecal immunochemical tests (FITs) conducted in colorectal cancer (CRC) screening could lead to performing unnecessary colonoscopies. Hemorrhoids are a possible cause of FP FIT results; however, studies on this topic are extremely rare. We investigated whether hemorrhoids are associated with FP FIT results. Materials and Methods A retrospective study was conducted at a university hospital in Korea from June 2013 to May 2015. Of the 34547 individuals who underwent FITs, 3946 aged ≥50 years who underwent colonoscopies were analyzed. Logistic regression analysis was performed to determine factors associated with FP FIT results. Results Among 3946 participants, 704 (17.8%) showed positive FIT results and 1303 (33.0%) had hemorrhoids. Of the 704 participants with positive FIT results, 165 had advanced colorectal neoplasia (ACRN) and 539 had no ACRN (FP results). Of the 1303 participants with hemorrhoids, 291 showed FP results, of whom 81 showed FP results because of hemorrhoids only. Participants with hemorrhoids had a higher rate of FP results than those without hemorrhoids (291/1176, 24.7% vs. 248/2361, 10.5%; p<0.001). Additionally, the participants with hemorrhoids as the only abnormality had a higher rate of FP results than those experiencing no such abnormalities (81/531, 15.3% vs. 38/1173, 3.2%; p<0.001). In multivariate analysis, the presence of hemorrhoids was identified as an independent predictor of FP results (adjusted odds ratio, 2.76; 95% confidence interval, 2.24–3.40; p<0.001). Conclusion Hemorrhoids are significantly associated with FP FIT results. Their presence seemed to be a non-negligible contributor of FP results in FIT-based CRC screening programs. PMID:27873508
Ogawa, T; Kuribayashi, S; Shimauchi, H; Toda, T; Hamada, S
1992-01-01
Outer membrane proteins (OMP) of Porphyromonas endodontalis HG 370 (ATCC 35406) were prepared from the cell envelope fraction of the organisms. The cell envelope that had been obtained by sonication of the whole cells was extracted in 2% lithium dodecyl sulfate and then successively chromatographed with Sephacryl S-200 HR and DEAE-Sepharose Fast Flow. Two OMP fractions, OMP-I and OMP-II, were obtained, and their immunochemical properties and induction of specific antibodies were examined. The OMP-I preparation consisted of a major protein with an apparent molecular mass of 31 kDa and other moderate to minor proteins of 40.3, 51.4, 67, and 71.6 kDa, while the OMP-II preparation contained 14-, 15.5-, 27-, and 44-kDa proteins as revealed by sodium dodecyl sulfate-polyacrylamide gel electrophoretic analysis. OMP-I was found to form hydrophilic diffusion pores by incorporation into artificial liposomes composed of egg yolk phosphatidylcholine and dicetylphosphate, indicating that OMP-I exhibited significant porin activity. However, the liposomes containing heat-denatured OMP-I were scarcely active. Spontaneous and antigen-specific immunoglobulin M (IgM)-, IgG-, and IgA-secreting spot-forming cells (SFC) enzymatically dissociated into single-cell suspensions from chronically inflamed periapical tissues and were enumerated by enzyme-linked immunospot assay. In patients with radicular cysts or dental granulomas, the major isotype of spontaneous SFC was IgG. In radicular cysts, the OMP-II-specific IgG SFC represented 0.13% of the total IgG SFC, while the antigen-specific IgA or IgM SFC was not observed. It was also found that none of these mononuclear cells produced antibodies specific for OMP-I or lipopolysaccharide of P. endodontalis. Images PMID:1328059
Ibrahim, Ahmed Ragaa Nour; Kawamoto, Seiji; Aki, Tsunehiro; Shimada, Yayoi; Rikimaru, Satoshi; Onishi, Nobukazu; Babiker, Elfadil Elfadl; Oiso, Isao; Hashimoto, Kunihiko; Hayashi, Takaharu; Ono, Kazuhisa
2010-01-01
Japanese cedar (Cryptomeria japonica) pollen is a major cause of seasonal pollinosis in Japan. Protease activity in the pollen grains may trigger pro-allergic responses but no such proteases have yet been identified as pollen allergens. We report the molecular cloning and immunochemical characterization of a novel C. japonica pollen allergen belonging to the aspartic protease family. We focused on the C. japonica pollen allergen spot No. 63 (CPA63, 47.5% IgE binding frequency) on our 2-dimensional IgE immunoblot map. The internal amino acid sequences were determined using time-of-flight mass spectrometry. Full-length cpa63 cDNA was cloned by rapid amplification of cDNA ends (RACE)-PCR. Recombinant CPA63 (r-CPA63) was expressed using the baculovirus-insect cell culture system and its IgE binding capacity was analyzed by enzyme-linked immunosorbent assay (ELISA). The proteolytic activity of r-CPA63 was also assessed using a putative mature enzyme produced upon autolysis. cpa63 cDNA encoded a 472 amino acid polypeptide showing about 40% sequence identity to members of the plant atypical aspartic protease family. ELISA showed that r-CPA63 was recognized by IgE antibodies in the serum of 58% (18/31) of Japanese cedar pollinosis patients. We also demonstrated an aspartic protease-like enzyme activity of the putative mature r-CPA63. We have identified the first plant aspartic protease allergen from Japanese cedar pollen. The availability of the CPA63 sequence and its recombinant allergen production system are useful not only for pharmaceutical applications but also for further examination of the role of protease activity in the pathogenesis of cedar pollinosis. 2010 S. Karger AG, Basel.
Fedeli, Ugo; Zorzi, Manuel; Urso, Emanuele D L; Gennaro, Nicola; Dei Tos, Angelo P; Saugo, Mario
2015-11-15
Colorectal cancer (CRC) screening programs based on the fecal immunochemical test (FIT) were found to reduce overall CRC surgery rates, but to the authors' knowledge data by subsite are lacking. The objective of the current study was to assess the impact of FIT-based screening on proximal and distal CRC surgical resection rates. The Veneto region in Italy can be subdivided into 3 areas with staggered introduction of FIT-based screening programs: early (2002-2004), intermediate (2005-2007), and late (2008-2009) areas. Time series of proximal and distal CRC surgery were investigated in the 3 populations between 2001 and 2012 by Joinpoint regression analysis and segmented Poisson regression models. The impact of screening was similar in the study populations. Rates of distal CRC surgical resection were stable before screening, increased at the time of screening implementation (rate ratio [RR], 1.25; 95% confidence interval [95% CI], 1.14-1.37), and thereafter declined by 10% annually (RR, 0.90; 95% CI, 0.88-0.92). Rates of proximal CRC surgical resection increased by 4% annually before screening (RR, 1.04; 95% CI, 1.03-1.05) but, after a peak at the time of screening initiation, the trend was reversed. The percentage represented by proximal CRC surgery rose from 28% in 2001 to 41% in 2012. In this natural multiple-baseline experiment, consistent findings across each time series demonstrated that FIT-based screening programs have an impact both on proximal and distal CRC surgery rates. However, underlying preexisting epidemiological trends are leading to a rapidly increasing percentage of proximal CRC. © 2015 American Cancer Society.
Clarke, Nicholas; McNamara, Deirdre; Kearney, Patricia M; O'Morain, Colm A; Shearer, Nikki; Sharp, Linda
2016-12-01
This study aimed to investigate the effects of sex and deprivation on participation in a population-based faecal immunochemical test (FIT) colorectal cancer screening programme. The study population included 9785 individuals invited to participate in two rounds of a population-based biennial FIT-based screening programme, in a relatively deprived area of Dublin, Ireland. Explanatory variables included in the analysis were sex, deprivation category of area of residence and age (at end of screening). The primary outcome variable modelled was participation status in both rounds combined (with "participation" defined as having taken part in either or both rounds of screening). Poisson regression with a log link and robust error variance was used to estimate relative risks (RR) for participation. As a sensitivity analysis, data were stratified by screening round. In both the univariable and multivariable models deprivation was strongly associated with participation. Increasing affluence was associated with higher participation; participation was 26% higher in people resident in the most affluent compared to the most deprived areas (multivariable RR=1.26: 95% CI 1.21-1.30). Participation was significantly lower in males (multivariable RR=0.96: 95%CI 0.95-0.97) and generally increased with increasing age (trend per age group, multivariable RR=1.02: 95%CI, 1.01-1.02). No significant interactions between the explanatory variables were found. The effects of deprivation and sex were similar by screening round. Deprivation and male gender are independently associated with lower uptake of population-based FIT colorectal cancer screening, even in a relatively deprived setting. Development of evidence-based interventions to increase uptake in these disadvantaged groups is urgently required. Copyright © 2016. Published by Elsevier Inc.
Osborne, Joanne M; Wilson, Carlene; Duncan, Amy; Cole, Stephen R; Flight, Ingrid; Turnbull, Deborah; Hughes, Donna L; Young, Graeme P
2017-08-01
Participation at the recommended intervals is critical for screening to be effective in reducing colorectal cancer (CRC) incidence. This study describes patterns of screening participation over four rounds of fecal immunochemical testing (FIT) to identify whether demographic variables and prior screening satisfaction are significantly associated with patterns of re-participation. Baseline surveys were mailed to 4000 South Australians randomly selected from the electoral-roll. Respondents (n = 1928/48.2%) were offered four annual FIT rounds. Screening participation and satisfaction at each round were recorded. Study participation was 58.5, 66.9, 73.1 and 71.4% respectively over four rounds. Three participation patterns were described: consistent participation (43.1%), consistent non-participation (26.4%) and inconsistent participation (changeable; 30.5%), including intermittent and sustained change patterns. Sustained change described those who changed participatory behavior and then maintained for at least two rounds (n = 375/19.5%). Older people, and those not working were most likely to sustain participation. Younger invitees, especially men, were more likely to change participatory behavior and sustain the change. People with higher disadvantage, less education, not working and with no prior (pre-trial) screening experience were more likely to start participating and drop out. People dissatisfied with a prior screening test, including finding aspects embarrassing or unpleasant, were also more likely not to participate in annual screening or to drop out. The findings identify those at risk of non- or inconsistent participation in rescreening. They should aid targeting of interventions for demographic groups at risk and ensuring screening experiences are not perceived as unpleasant or difficult.
Chiu, Han-Mo; Chen, Sam Li-Sheng; Yen, Amy Ming-Fang; Chiu, Sherry Yueh-Hsia; Fann, Jean Ching-Yuan; Lee, Yi-Chia; Pan, Shin-Liang; Wu, Ming-Shiang; Liao, Chao-Sheng; Chen, Hsiu-Hsi; Koong, Shin-Lan; Chiou, Shu-Ti
2015-09-15
The effectiveness of fecal immunochemical testing (FIT) in reducing colorectal cancer (CRC) mortality has not yet been fully assessed in a large, population-based service screening program. A prospective cohort study of the follow-up of approximately 5 million Taiwanese from 2004 to 2009 was conducted to compare CRC mortality for an exposed (screened) group and an unexposed (unscreened) group in a population-based CRC screening service targeting community residents of Taiwan who were 50 to 69 years old. Given clinical capacity, this nationwide screening program was first rolled out in 2004. In all, 1,160,895 eligible subjects who were 50 to 69 years old (ie, 21.4% of the 5,417,699 subjects of the underlying population) participated in the biennial nationwide screening program by 2009. The actual effectiveness in reducing CRC mortality attributed to the FIT screening was 62% (relative rate for the screened group vs the unscreened group, 0.38; 95% confidence interval, 0.35-0.42) with a maximum follow-up of 6 years. The 21.4% coverage of the population receiving FIT led to a significant 10% reduction in CRC mortality (relative rate, 0.90; 95% confidence interval, 0.84-0.95) after adjustments for a self-selection bias. This large, prospective Taiwanese cohort undergoing population-based FIT screening for CRC had the statistical power to demonstrate a significant CRC mortality reduction, although the follow-up time was short. Although such findings are informative for health decision makers, continued follow-up of this large cohort will be required to estimate the long-term impact of FIT screening if the covered population is expanded. © 2015 American Cancer Society.
Potential of soluble CD26 as a serum marker for colorectal cancer detection
Cordero, Oscar J; Imbernon, Monica; Chiara, Loretta De; Martinez-Zorzano, Vicenta S; Ayude, Daniel; de la Cadena, Maria Paez; Rodriguez-Berrocal, F Javier
2011-01-01
Colorectal cancer is characterized by a low survival rate even though the basis for colon cancer development, which involves the evolution of adenomas to carcinoma, is known. Moreover, the mortality rates continue to rise in economically transitioning countries although there is the opportunity to intervene in the natural history of the adenoma–cancer sequence through risk factors, screening, and treatment. Screening in particular accounted for most of the decline in colorectal cancer mortality achieved in the USA during the period 1975-2000. Patients show a better prognosis when the neoplasm is diagnosed early. Among the variety of screening strategies, the methods range from invasive and costly procedures such as colonoscopy to more low-cost and non-invasive tests such as the fecal occult blood test (guaiac and immunochemical). As a non-invasive biological serum marker would be of great benefit because of the performance of the test, several biomarkers, including cytologic assays, DNA and mRNA, and soluble proteins, have been studied. We found that the soluble CD26 (sCD26) concentration is diminished in serum of colorectal cancer patients compared to healthy donors, suggesting the potential utility of a sCD26 immunochemical detection test for early diagnosis. sCD26 originates from plasma membrane CD26 lacking its transmembrane and cytoplasmic domains. Some 90%–95% of sCD26 has been associated with serum dipeptidyl peptidase IV (DPP-IV) activity. DPP-IV, assigned to the CD26 cluster, is a pleiotropic enzyme expressed mainly on epithelial cells and lymphocytes. Our studies intended to validate this test for population screening to detect colorectal cancer and advanced adenomas are reviewed here. PMID:21773075
1989-01-01
P-cadherin is a subclass of Ca2+-dependent cell-cell adhesion molecules present in mouse placenta, where its localization suggests a function of connecting the embryo to the uterus (Nose, A., and M. Takeichi. 1986. J. Cell Biol. 103:2649-2658). We recently identified a human cadherin detected by an mAb capable of disrupting cell-cell adhesion of A-431 cells, and found that it was closely related immunochemically to mouse P-cadherin. Curiously, this cadherin was undetectable in human placenta by immunohistochemical examination (Shimoyama, Y., S. Hirohashi, S. Hirano, M. Noguchi, Y. Shimosato, M. Takeichi, and O. Abe. 1989. Cancer Res. 49:2128-2133). We here report the cloning and sequencing of cDNA clone encoding the human homologue of mouse P- cadherin. The deduced amino acid sequence of the human P-cadherin consists of 829 amino acid and shows striking homology with mouse P- cadherin. On Northern blot analysis, human P-cadherin was scarcely expressed in human placenta in contrast to mouse P-cadherin, which was abundantly expressed in mouse placenta throughout pregnancy, and it was shown that E-cadherin, but not P-cadherin, was the major cadherin molecule in human placenta. Moreover, NIH3T3 cells transfected with human P-cadherin cDNA expressed the functional cadherin molecule, which was identical to the cadherin we had previously identified using the mAb, showing that this molecule really does mediate cell-cell adhesion and that the cadherin we detected immunochemically is undoubtedly human P-cadherin. The results obtained in this study support the idea that P- cadherin plays little role, if any, in Ca2+-dependent cell-cell binding in human placental tissue at least after several weeks of pregnancy. PMID:2793940
Knudsen, Markus Dines; Berstad, Paula; Hjartåker, Anette; Gulichsen, Elisabeth Haagensen; Hoff, Geir; de Lange, Thomas; Bernklev, Tomm; Botteri, Edoardo
2017-08-08
To reduce colorectal cancer (CRC) mortality through population-based screening programmes using faecal tests, it is important that individuals continue to participate in the repeated rounds of screening. We aimed to identify lifestyle predictors for discontinuation of faecal immunochemical test (FIT) screening after the first round, as well as lifestyle predictors for colorectal neoplasia detected in the second-round FIT screening. In this longitudinal study, we invited 6959 individuals aged 50-74 years from south-east Norway for a first round of FIT screening and to complete a self-reported lifestyle questionnaire on demographic factors, body mass index (BMI, kg m -2 ), smoking habits, physical activity, consumption of alcohol and dietary items. Two years later, we estimated the associations between these factors, non-participation and screening results in the second round of FIT screening using adjusted odds ratios (ORs) and 95% confidence intervals (CIs). Of the 3114 responders to the questionnaire who completed the first-round FIT and who were invited to participate in second-round FIT screening, 540 (17%) did not participate. The OR and (95% CI) for discontinuation of FIT screening after the first round was 1.61 (1.24-2.10) for current smoking compared with non-smoking; 2.01 (1.25-3.24) for BMI⩾35 kg m -2 compared with BMI 16.9-24.9 kg m -2 and 0.70 (0.52-0.94) for physical activity in the third quartile vs the first. Among participants, smoking, high BMI and high alcohol consumption were associated with an increased odds of detecting colorectal neoplasia (n=107). These results may indicate that Norwegian FIT screening participants who discontinue after the first round have lifestyle behaviours associated with increased risk of CRC.
Goede, S Lucas; Rabeneck, Linda; van Ballegooijen, Marjolein; Zauber, Ann G; Paszat, Lawrence F; Hoch, Jeffrey S; Yong, Jean H E; Kroep, Sonja; Tinmouth, Jill; Lansdorp-Vogelaar, Iris
2017-01-01
The ColonCancerCheck screening program for colorectal cancer (CRC) in Ontario, Canada, is considering switching from biennial guaiac fecal occult blood test (gFOBT) screening between age 50-74 years to the more sensitive, but also less specific fecal immunochemical test (FIT). The aim of this study is to estimate whether the additional benefits of FIT screening compared to gFOBT outweigh the additional costs and harms. We used microsimulation modeling to estimate quality adjusted life years (QALYs) gained and costs of gFOBT and FIT, compared to no screening, in a cohort of screening participants. We compared strategies with various age ranges, screening intervals, and cut-off levels for FIT. Cost-efficient strategies were determined for various levels of available colonoscopy capacity. Compared to no screening, biennial gFOBT screening between age 50-74 years provided 20 QALYs at a cost of CAN$200,900 per 1,000 participants, and required 17 colonoscopies per 1,000 participants per year. FIT screening was more effective and less costly. For the same level of colonoscopy requirement, biennial FIT (with a high cut-off level of 200 ng Hb/ml) between age 50-74 years provided 11 extra QALYs gained while saving CAN$333,300 per 1000 participants, compared to gFOBT. Without restrictions in colonoscopy capacity, FIT (with a low cut-off level of 50 ng Hb/ml) every year between age 45-80 years was the most cost-effective strategy providing 27 extra QALYs gained per 1000 participants, while saving CAN$448,300. Compared to gFOBT screening, switching to FIT at a high cut-off level could increase the health benefits of a CRC screening program without considerably increasing colonoscopy demand.
Johnson, David A; Barclay, Robert L; Mergener, Klaus; Weiss, Gunter; König, Thomas; Beck, Jürgen; Potter, Nicholas T
2014-01-01
Screening improves outcomes related to colorectal cancer (CRC); however, suboptimal participation for available screening tests limits the full benefits of screening. Non-invasive screening using a blood based assay may potentially help reach the unscreened population. To compare the performance of a new Septin9 DNA methylation based blood test with a fecal immunochemical test (FIT) for CRC screening. In this trial, fecal and blood samples were obtained from enrolled patients. To compare test sensitivity for CRC, patients with screening identified colorectal cancer (n = 102) were enrolled and provided samples prior to surgery. To compare test specificity patients were enrolled prospectively (n = 199) and provided samples prior to bowel preparation for screening colonoscopy. Plasma and fecal samples were analyzed using the Epi proColon and OC Fit-Check tests respectively. For all samples, sensitivity for CRC detection was 73.3% (95% CI 63.9-80.9%) and 68.0% (95% CI 58.2-76.5%) for Septin9 and FIT, respectively. Specificity of the Epi proColon test was 81.5% (95% CI 75.5-86.3%) compared with 97.4% (95% CI 94.1-98.9%) for FIT. For paired samples, the sensitivity of the Epi proColon test (72.2% -95% CI 62.5-80.1%) was shown to be statistically non-inferior to FIT (68.0%-95% CI 58.2-76.5%). When test results for Epi proColon and FIT were combined, CRC detection was 88.7% at a specificity of 78.8%. At a sensitivity of 72%, the Epi proColon test is non- inferior to FIT for CRC detection, although at a lower specificity. With negative predictive values of 99.8%, both methods are identical in confirming the absence of CRC. ClinicalTrials.gov NCT01580540.
Chiba, M; Xu, X; Nishime, J A; Balani, S K; Lin, J H
1997-09-01
Montelukast (L-706,631, MK-0476, SINGULAIR), a potent and selective leukotriene D4 (CysLT1) receptor antagonist, is currently under development for the treatment of asthma. In vitro studies were conducted using human liver microsomes to evaluate: 1) the difference in the metabolic kinetics of montelukast between adult and pediatric subjects; 2) the relative contribution of flavin-containing monooxygenase and cytochrome P450 (P450) to the sulfoxidation; and 3) the P450 isoforms responsible for montelukast oxidation. No statistically significant difference was observed in the in vitro kinetics for acyl glucuronidation and oxidative metabolism between the two age groups. Results from studies on heat inactivation of flavin-containing monooxygenase and immunochemical inhibition by an anti-rat NADPH P450 reductase antibody on montelukast oxidation indicated that all oxidative metabolism of montelukast-including diastereomeric sulfoxidations, as well as 21- and methyl-hydroxylations-are catalyzed exclusively by P450. Five in vitro approaches have been used to identify the P450 isoforms responsible for the human liver microsomal oxidation of montelukast. The experimental results consistently indicated that CYP3A4 catalyzes sulfoxidation and 21-hydroxylation, whereas CYP2C9 selectively mediates methyl-hydroxylation.
Mogler, Lukas; Wilde, Maurice; Huppertz, Laura M; Weinfurtner, Georg; Franz, Florian; Auwärter, Volker
2018-05-01
Indole-, indazole-, or azaindole-based synthetic cannabinoids (SCs), bearing a cumyl substituent are a widespread, recreationally used subgroup of new psychoactive substances (NPS). The latest cumyl-derivative, CUMYL-PEGACLONE, emerged in December 2016 on the German drug market. The substance features a novel γ-carboline core structure, which is most likely synthesized to bypass generic legislative approaches to control SCs by prohibiting distinct core structures. Using liquid chromatography-tandem mass spectrometry and liquid chromatography-high resolution mass spectrometry techniques, the main in vivo phase I metabolites of this new substance were detected. A pooled human liver microsome assay was applied to generate in vitro reference spectra of CUMYL-PEGACLONE phase I metabolites. Additionally, 30 urine samples were investigated leading to 22 in vivo metabolites. A metabolite mono-hydroxylated at the γ-carbolinone core system and a metabolite with an additional carbonyl group at the pentyl side chain were evaluated as highly specific and sensitive markers to proof CUMYL-PEGACLONE uptake. Moreover, 3 immunochemical assays commonly used for SC screening in urine were tested for their capability of detecting the new drug but failed due to insufficient cross-reactivity. Copyright © 2018 John Wiley & Sons, Ltd.
Jodra, Adrián; López, Miguel Ángel; Escarpa, Alberto
2015-02-15
An electrochemical magnetoimmunosensor involving magnetic beads and disposable carbon screen-printed electrode (CSPE) for Fumonosins (FB1, FB2 and FB3) has been developed and evaluated through a certified reference material (CRM) and beer samples. Once the immunochemical reactions took place on the magnetic beads solution, they were confined on the surface of CSPE, where electrochemical detection is achieved through the addition of suitable substrate and mediator for enzymatic tracer (Horseradish peroxidase--HRP). A remarkable detection limit of 0.33 μg L(-1), outstanding repeatability and reproducibility (RSD(intraday) of 5.6% and 2.9%; RSD(interday) of 6.9% and 6.0%; both for 0 and 5 μg L(-1) FB1 respectively), and excellent accuracy with recovery rate of 85-96% showed the suggested approach to be a very suitable screening tool for the analysis of Fumonisin B1 and B2 in food samples. A simultaneous simplified calibration and analysis protocol allows a fast and reliable determination of Fumonisin in beer samples with recovery rate of 87-105%. This strategy enhanced the analytical merits of immunosensor approach towards truly disposable tools for food-safety monitoring. Copyright © 2014 Elsevier B.V. All rights reserved.
Comparative Evaluation of Quantitative Test Methods for Gases on a Hard Surface
2017-02-01
COMPARATIVE EVALUATION OF QUANTITATIVE TEST METHODS FOR GASES ON A HARD SURFACE ECBC-TR-1426 Vipin Rastogi...1 COMPARATIVE EVALUATION OF QUANTITATIVE TEST METHODS FOR GASES ON A HARD SURFACE 1. INTRODUCTION Members of the U.S. Environmental...Generator 4 2.4 Experimental Design Each quantitative method was performed three times on three consecutive days. For the CD runs, three
Naturally occurring pepsin agglutinators in the serum of subhuman primates*
Litwin, S. D.
1970-01-01
Antibodies directed against both human and infrahuman pepsin digested γ-globulin were present in a majority of the primate sera tested. The subhuman pepsin agglutinators paralleled previously described human pepsin agglutinators in respect to their wide distribution in normal sera, their specificity and cross-reactivity, and their immunochemical features. The pepsin agglutinators† at different primate levels appeared closely related. Among the subhuman pepsin agglutinators a subspecificity was described for a subhuman primate antigen. This finding suggested some limited differences between the subhuman pepsin agglutinators and the human pepsin agglutinators. Experimental immunization of four cynomologous monkeys failed to elicit or alter these serum reactants. PMID:4097824
[Determination of antiphospholipid antibodies in serum using ELISA].
Fialová, L; Mikulíková, L; Malbohan, I; Průcha, M; Palecková, A; Cerný, V
1994-05-01
The authors compare two ELISA methods for the assessment of antiphospholipid antibodies, classes IgG and IgM, in serum: ELISA Pin Plate System ALPHA DIALAB Co. and the ELISA method developed in the Research Institute of Rheumatic Diseases. Both methods use cardiolipin as antigen. In the Pin Plate test the immunochemical reaction antigen/antibody does not take place at the surface of the pits of the microtitration plates but on the tip of the next plate. The results of examinations of antiphospholipid antibodies obtained by the tested methods are comparable, the Pin Plate test is quicker and more sensitive, but its price limits routine use.
Cloning, bacterial expression and crystallization of Fv antibody fragments
NASA Astrophysics Data System (ADS)
E´, Jean-Luc; Boulot, Ginette; Chitarra, V´ronique; Riottot, Marie-Madeleine; Souchon, H´le`ne; Houdusse, Anne; Bentley, Graham A.; Narayana Bhat, T.; Spinelli, Silvia; Poljak, Roberto J.
1992-08-01
The variable Fv fragments of antibodies, cloned in recombinant plasmids, can be expressed in bacteria as functional proteins having immunochemical properties which are very similar or identical with those of the corresponding parts of the parent eukaryotic antibodies. They offer new possibilities for the study of antibody-antigen interactions since the crystals of Fv fragments and of their complexes with antigen reported here diffract X-rays to a higher resolution that those obtained with the cognate Fab fragments. The Fv approach should facilitate the structural study of the combining site of antibodies and the further characterization of antigen-antibody interactions by site-directed mutagenesis experiments.
Toxin Detection by Surface Plasmon Resonance
Hodnik, Vesna; Anderluh, Gregor
2009-01-01
Significant efforts have been invested in the past years for the development of analytical methods for fast toxin detection in food and water. Immunochemical methods like ELISA, spectroscopy and chromatography are the most used in toxin detection. Different methods have been linked, e.g. liquid chromatography and mass spectrometry (LC-MS), in order to detect as low concentrations as possible. Surface plasmon resonance (SPR) is one of the new biophysical methods which enables rapid toxin detection. Moreover, this method was already included in portable sensors for on-site determinations. In this paper we describe some of the most common methods for toxin detection, with an emphasis on SPR. PMID:22573957
NASA Astrophysics Data System (ADS)
Agafonova, L. E.; Shumyantseva, V. V.; Archakov, A. I.
2014-06-01
The quartz crystal microbalance (QCM) was exploited for cardiac markers detection and kinetic studies of immunochemical reaction of cardiac troponin I (cTnI) and human heart fatty acid binding protein (H-FABP) with the corresponding monoclonal antibodies in undiluted plasma (serum) and standard solutions. The QCM technique allowed to dynamically monitor the kinetic differences in specific interactions and nonspecific sorption, without multiple labeling procedures and separation steps. The affinity binding process was characterized by the association (ka) and the dissociation (kd) kinetic constants and the equilibrium association (K) constant, all of which were obtained from experimental data.
[Reconstituting evaluation methods based on both qualitative and quantitative paradigms].
Miyata, Hiroaki; Okubo, Suguru; Yoshie, Satoru; Kai, Ichiro
2011-01-01
Debate about the relationship between quantitative and qualitative paradigms is often muddled and confusing and the clutter of terms and arguments has resulted in the concepts becoming obscure and unrecognizable. In this study we conducted content analysis regarding evaluation methods of qualitative healthcare research. We extracted descriptions on four types of evaluation paradigm (validity/credibility, reliability/credibility, objectivity/confirmability, and generalizability/transferability), and classified them into subcategories. In quantitative research, there has been many evaluation methods based on qualitative paradigms, and vice versa. Thus, it might not be useful to consider evaluation methods of qualitative paradigm are isolated from those of quantitative methods. Choosing practical evaluation methods based on the situation and prior conditions of each study is an important approach for researchers.
Chen, Hongda; Werner, Simone; Brenner, Hermann
2017-10-01
Fecal immunochemical tests (FITs) are used in colorectal cancer (CRC) screening. We compared detection of CRCs and colorectal neoplasms by FITs using fresh samples (collected into buffer-filled tubes) vs frozen samples, and we assessed the effects of seasonal variations in ambient temperature on test performance. We performed a prospective study of 3466 individuals (50% male; mean age, 62 years) undergoing screening colonoscopies at 20 gastroenterology practices in southern Germany from November 2008 through September 2014. Frozen stool samples (collected and frozen by patients through February 2012, n = 1644) and fresh stool samples (collected by patients into buffer-filled tubes after February 2012, n = 1822) were obtained; hemoglobin (Hgb) concentrations were measured by using a commercial, quantitative FIT (cutoff value for positive result, 17 μg Hgb/g feces). Colonoscopy results were used as the gold standard, with results categorized as CRC, advanced adenoma, non-advanced adenoma, or no colorectal neoplasm. Differences in detection of colorectal neoplasms with fresh vs frozen samples were compared by using Wilcoxon rank sum test (continuous variables) and Fisher exact test (categorical variables). We also compared test performance when samples were collected during different seasons (based on outdoor temperature less than 8°, 8°-15°, or more than 15°). Of the samples analyzed by FIT, 12.8% of frozen stool samples (95% confidence interval [CI], 11.3%-14.5%) and 8.7% of fresh stool samples (95% CI, 7.5%-10.1%) had positive results (P value for difference < .001). When adjusting the Hgb cutoff value to produce the same percentage of positive results for fresh and frozen samples (10% and 5%), FIT with frozen vs fresh samples detected colorectal neoplasms with similar levels of sensitivity and specificity. For example, at cutoff values that produced 5% positive results for each sample type, FIT detected advanced neoplasms with 27.8% sensitivity when frozen samples were used (95% CI, 21.4%-35.1%) and 25.6% sensitivity when fresh samples were used (95% CI, 19.8%-32.1%). Specificity values were 97.7% when frozen samples were used (95% CI, 96.8%-98.4%) and 97.6% when fresh samples were used (95% CI, 96.7%-98.3%). We did not observe any differences in detection of neoplasms during different seasons that were based on outdoor temperature. In a prospective study of 3466 individuals who underwent screening colonoscopies and received FITs, we found that use of fresh vs frozen samples slightly affected positivity rates and the proportions of CRCs or adenomas detected at the recommended Hgb cutoff value. However, after we adjusted Hgb cutoff values to produce equal proportions of positive results for fresh vs frozen samples, the performance of the FIT was similar with each sample type. Season of sample collection (based on outdoor temperature) did not affect detection of CRC using either sample type in this study from Middle Europe. Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.
Chen, Jing; Wang, Shu-Mei; Meng, Jiang; Sun, Fei; Liang, Sheng-Wang
2013-05-01
To establish a new method for quality evaluation and validate its feasibilities by simultaneous quantitative assay of five alkaloids in Sophora flavescens. The new quality evaluation method, quantitative analysis of multi-components by single marker (QAMS), was established and validated with S. flavescens. Five main alkaloids, oxymatrine, sophocarpine, matrine, oxysophocarpine and sophoridine, were selected as analytes to evaluate the quality of rhizome of S. flavescens, and the relative correction factor has good repeatibility. Their contents in 21 batches of samples, collected from different areas, were determined by both external standard method and QAMS. The method was evaluated by comparison of the quantitative results between external standard method and QAMS. No significant differences were found in the quantitative results of five alkaloids in 21 batches of S. flavescens determined by external standard method and QAMS. It is feasible and suitable to evaluate the quality of rhizome of S. flavescens by QAMS.
Amelogenin-Ameloblastin Spatial Interaction around Maturing Enamel Rods.
Mazumder, P; Prajapati, S; Bapat, R; Moradian-Oldak, J
2016-08-01
Amelogenin and ameloblastin are 2 extracellular matrix proteins that are essential for the proper development of enamel. We recently reported that amelogenin and ameloblastin colocalized during the secretory stage of enamel formation when nucleation of enamel crystallites occurs. Direct interactions between the 2 proteins have been also demonstrated in our in vitro studies. Here, we explore interactions between their fragments during enamel maturation. We applied in vivo immunofluorescence imaging, quantitative co-localization analysis, and a new FRET (fluorescence resonance energy transfer) technique to demonstrate ameloblastin and amelogenin interaction in the maturing mouse enamel. Using immunochemical analysis of protein samples extracted from 8-d-old (P8) first molars from mice as a model for maturation-stage enamel, we identified the ~17-kDa ameloblastin (Ambn-N) and the TRAP (tyrosine-rich amelogenin peptide) fragments. We used Ambn-N18 and Ambn-M300 antibodies raised against the N-terminal and C-terminal segments of ameloblastin, as well as Amel-FL and Amel-C19 antibodies against full-length recombinant mouse amelogenin (rM179) and C-terminal amelogenin, respectively. In transverse sections, co-localization images of N-terminal fragments of amelogenin and ameloblastin around the prism boundary revealed the "fish net" pattern of the enamel matrix. Using in vivo FRET microscopy, we further demonstrated spatial interactions between amelogenin and ameloblastin N-terminal fragments. In the maturing mouse enamel, the association of these residual protein fragments created a discontinuity between enamel rods, which we suggest is important for support and maintenance of enamel rods and eventual contribution to unique enamel mechanical properties. We present data that support cooperative functions of enamel matrix proteins in mediating the structural hierarchy of enamel and that contribute to our efforts to design and develop enamel biomimetic material. © International & American Associations for Dental Research 2016.
Uchida, Koji; Shibata, Takahiro; Toyokuni, Shinya; Daniel, Bareket; Zarkovic, Kamelija; Zarkovic, Neven; Sasson, Shlomo
2018-05-25
Non-enzymatic peroxidation of polyunsaturated fatty acids (PUFA) results in the formation of various α,β-unsaturated aldehydes, of which 4-hydroxyalkenals are abundant. The propensity of n-6 PUFA, such as linoleic acid, γ-linolenic acid and arachidonic acid, to undergo radical-induced peroxidation and generate 4-hydroxy-2E-nonenal (4-HNE) has been widely demonstrated. The ability of the latter to form covalent adducts with macromolecules and modify cellular functions has been linked to numerous pathological processes. Concomitantly, evidence has accumulated on specific signaling properties of low concentrations of 4-HNE that may induce hormetic and protective responses to peroxidation stress in cells. It has long been known that peroxidation of PUFA, and particularly arachidonic acid, also give rise to 4-hydroxy-2E,6Z-dodecadienal (4-HDDE), which is more chemically reactive than 4-HNE. Few studies on 4-HDDE revealed its ability to avidly interact covalently with electronegative moieties in macromolecules and to its ability to selectively activate the transcriptional regulator Peroxisome Proliferator-Activated Receptor (PPAR)-β/δ. The research on 4-HDDE has been impeded due to the lack of available pure 4-HDDE and antibodies that recognize 4-HDDE-modified epitopes in proteins. The purpose of this study was to employ an established procedure to synthesize 4-HDDE and use it to create and characterize a monoclonal antibody against 4-HDDE-modified proteins and establish its application for ELISA and immunohistochemical analysis of cells and tissues and further expand lipid peroxidation research. Copyright © 2018 Elsevier Inc. All rights reserved.
Exacerbated Glial Response in the Aged Mouse Hippocampus Following Controlled Cortical Impact Injury
Sandhir, Rajat; Onyszchuk, Gregory; Berman, Nancy E. J.
2008-01-01
Old age is associated with enhanced susceptibility to and poor recovery from brain injury. An exacerbated microglial and astrocyte response to brain injury might be involved in poor outcomes observed in the elderly. The present study was therefore designed to quantitate the expression of markers of microglia and astrocyte activation using real-time RT-PCR, immunoblot and immunohistochemical analysis in aging brain in response to brain injury. We examined the hippocampus, a region that undergoes secondary neuron death, in aged (21–24 month) and adult (5–6 month) mice following controlled cortical impact (CCI) injury to the sensorimotor cortex. Basal mRNA expression of CD11b and Iba1, markers of activated microglia, was higher in aged hippocampus as compared to the adult. The mRNA expression of microglial markers increased and reached maximum 3 days post injury in both adult and aged mice, but was higher in the aged mice at all time points studied, and in the aged mice the return to baseline levels was delayed. Basal mRNA expression of GFAP and S100B, markers of activated astrocytes, was higher in aged mice. Both markers increased and reached maximum 7 days post injury. The mRNA expression of astrocyte markers returned to near basal levels rapidly after injury in the adult mice, whereas again in the aged mice return to baseline was delayed. Immunochemical analysis using Iba1 and GFAP antibodies indicate accentuated glial responses in the aged hippocampus after injury. The pronounced and prolonged activation of microglia and astrocytes in hippocampus may contribute to worse cognitive outcomes in the elderly following TBI. PMID:18692046
Abouzied, M M; Azcona, J I; Braselton, W E; Pestka, J J
1991-01-01
To assess the potential for mycotoxin contamination of the human food supply following the 1988 U.S. drought, 92 grain food samples were purchased from retail outlets in the summer of 1989 and surveyed for aflatoxin B1, zearalenone, and deoxynivalenol (DON [vomitoxin]) by monoclonal antibody-based competitive enzyme-linked immunosorbent assay (ELISA). Only one sample (buckwheat flour) was found to contain aflatoxin B1 (12 ng/g), whereas zearalenone was found in 26% of the samples at a mean concentration of 19 ng/g. In contrast, the DON ELISA was positive in 50% of the samples at a detection level of 1.0 micrograms/g. Between 63 and 88% of corn cereals, wheat flour/muffin mixes, rice cereals, and corn meal/muffin mixes yielded positive results for DON, whereas 25 to 50% of oat cereals, wheat- and oat-based cookies/crackers, corn chips, popcorn, and mixed-grain cereals were positive for DON. The mean DON content of the positive samples was 4.0 micrograms/g, and the minimum and maximum levels were 1.2 and 19 micrograms/g, respectively. When positive ELISA samples were also analyzed by high-performance liquid chromatography, a strong correlation between the two methods was found. The presence of DON in the two highest samples, corn meal and mixed-grain cereal, which contained 19 and 16 micrograms/g, respectively, was quantitatively confirmed by gas chromatography-mass spectrometry. The results indicated that DON was present in 1989 retail food products at concentrations that exceeded those found in previous market surveys and that have been experimentally associated with impaired animal health. Images PMID:1828138
Peruffo, A; Giacomello, M; Montelli, S; Corain, L; Cozzi, B
2011-06-01
The enzyme aromatase (P450(AROM)) converts testosterone (T) into 17-β estradiol (E(2)) and is crucial for the control of development of the central nervous system during ontogenesis. The effects of E(2) in various brain areas are mediated by the estrogen receptor alpha (ER-α) and the estrogen receptor beta (ER-β). During fetal development, steroids are responsible for the sexual differentiation of the hypothalamus. Estrogens are also able to exert effects in other brain areas of the fetus including the frontal cortex, where they act through estrogen receptors (ERs) modulating cognitive function and affective behaviors. In this study we have determined the expression profiles of P450(AROM) and ERs in the fetal bovine frontal cortex by quantitative Real-Time PCR (qRT-PCR) throughout the prenatal development. The data show that the patterns of expression of both ERs are strongly correlated during pregnancy and increase in the last stage of gestation. On the contrary, the expression of P450(AROM) has no correlation with ERs expression and is not developmentally regulated. Moreover, we performed immunochemical studies showing that fetal neurons express P450(AROM) and the ERs. P450(AROM) is localized in the cytoplasm and only seldom present in the fine extensions of the cells; ER-α is detected predominantly in the soma whereas ER-β is only present in the nucleus of a few cells. This study provides new data on the development of the frontal cortex in a long gestation mammal with a large convoluted brain. Copyright © 2011 Elsevier Inc. All rights reserved.
DNA adducts: Mass spectrometry methods and future prospects
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farmer, P.B.; Brown, K.; Tompkins, E.
2005-09-01
Detection of DNA adducts is widely used for the monitoring of exposure to genotoxic carcinogens. Knowledge of the nature and amounts of DNA adducts formed in vivo also gives valuable information regarding the mutational effects that may result from particular exposures. The power of mass spectrometry (MS) to achieve qualitative and quantitative analyses of human DNA adducts has increased greatly in recent years with the development of improved chromatographic interfaces and ionisation sources. Adducts have been detected on nucleic acid bases, 2'-deoxynucleosides or 2'-deoxynucleotides, with LC-MS/MS being the favoured technique for many of these analyses. Our current applications of thismore » technique include the determination of N7-(2-carbamoyl-2-hydroxyethyl)-guanine, which was postulated to be found as a DNA repair product in urine following exposure to acrylamide, and of 8-oxo-7,8-dihydro-2'-deoxyguanosine and 8-oxo-7,8-dihydro-2'-deoxyadenosine, as markers of oxidative damage in human lymphocyte DNA. Higher sensitivity (with a detection limit of 1-10 adducts/10{sup 12} nucleotides) may be achieved by the use of accelerator mass spectrometry (AMS), although this requires the presence of certain isotopes, such as [{sup 14}C], in the material being analysed. In order to make this technique more amenable for studies of human exposure to environmental carcinogens, new postlabelling techniques, incorporating [{sup 14}C] into specific DNA adducts after formation, are being developed. It is expected that combining the use of advanced MS techniques with existing {sup 32}P-postlabelling and immunochemical methodologies will contribute greatly to the understanding of the burden of human exposure to environmental carcinogens.« less
An updated Asia Pacific Consensus Recommendations on colorectal cancer screening.
Sung, J J Y; Ng, S C; Chan, F K L; Chiu, H M; Kim, H S; Matsuda, T; Ng, S S M; Lau, J Y W; Zheng, S; Adler, S; Reddy, N; Yeoh, K G; Tsoi, K K F; Ching, J Y L; Kuipers, E J; Rabeneck, L; Young, G P; Steele, R J; Lieberman, D; Goh, K L
2015-01-01
Since the publication of the first Asia Pacific Consensus on Colorectal Cancer (CRC) in 2008, there are substantial advancements in the science and experience of implementing CRC screening. The Asia Pacific Working Group aimed to provide an updated set of consensus recommendations. Members from 14 Asian regions gathered to seek consensus using other national and international guidelines, and recent relevant literature published from 2008 to 2013. A modified Delphi process was adopted to develop the statements. Age range for CRC screening is defined as 50-75 years. Advancing age, male, family history of CRC, smoking and obesity are confirmed risk factors for CRC and advanced neoplasia. A risk-stratified scoring system is recommended for selecting high-risk patients for colonoscopy. Quantitative faecal immunochemical test (FIT) instead of guaiac-based faecal occult blood test (gFOBT) is preferred for average-risk subjects. Ancillary methods in colonoscopy, with the exception of chromoendoscopy, have not proven to be superior to high-definition white light endoscopy in identifying adenoma. Quality of colonoscopy should be upheld and quality assurance programme should be in place to audit every aspects of CRC screening. Serrated adenoma is recognised as a risk for interval cancer. There is no consensus on the recruitment of trained endoscopy nurses for CRC screening. Based on recent data on CRC screening, an updated list of recommendations on CRC screening is prepared. These consensus statements will further enhance the implementation of CRC screening in the Asia Pacific region. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Progesterone-associated proteins PP12 and PP14 in the human endometrium.
Rutanen, E M; Koistinen, R; Seppälä, M; Julkunen, M; Suikkari, A M; Huhtala, M L
1987-01-01
Two proteins, designated as PP12 and PP14 were originally isolated from soluble extracts of the human placenta and its adjacent membranes. We have shown that they are synthesized by decidualized/secretory endometrium and not by placenta. Both proteins occur at high concentrations in human amniotic fluid, which is therefore an excellent source for purification. PP12 is a 34-kDa glycoprotein, which has an N-terminal amino acid sequence of Ala-Pro-Trp-Gln-Cys-Ala-Pro-Cys-Ser-Ala. This is identical with that of somatomedin-binding protein purified from the amniotic fluid. PP12 too binds somatomedin-C, or IGF-I (insulin-like growth factor-I). Human secretory endometrium synthesizes and secretes PP12, and progesterone stimulates its secretion. PP14 is a 28-kDa glycoprotein. Its N-terminal sequence shows homology to that of beta-lactoglobulins from various species. We have found PP14 in the human endometrium, serum and milk. Immunologically, PP14 is related to progestagen-associated endometrial protein (PEP), alpha-2 pregnancy-associated endometrial protein (alpha-2, PEG), endometrial protein 15 (EP15), alpha-uterine protein (AUP) and chorionic alpha-2 microglobulin (CAG-2). In ovulatory menstrual cycles, the concentration of PP14 increases in endometrial tissue as the secretory changes advance. In serum, the PP14 concentration begins to rise later than the progesterone levels, and high serum PP14 levels are maintained for the first days of the next cycle. By contrast, no elevation of serum PP14 level is seen in anovulatory cycles. Our results show that progesterone-associated proteins are synthesized by the human endometrium and appear in the peripheral circulation, where they can be quantitatively measured using immunochemical techniques.
Abeyrathne, Priyanka D; Lam, Joseph S
2007-04-01
A major hurdle in characterizing bacterial membrane proteins by Western blotting is the ineffectiveness of transferring these proteins from sodium dodecyl sulfate -- polyacrylamide gel electrophoresis (SDS-PAGE) gel onto nitrocellulose membrane, using standard Western blot buffers and electrophoretic conditions. In this study, we compared a number of modified Western blotting buffers and arrived at a composition designated as the SDS-PAGE-Urea Lysis buffer. The use of this buffer and specific conditions allowed the reproducible transfer of highly hydrophobic bacterial membrane proteins with 2-12 transmembrane-spanning segments as well as soluble proteins onto nitrocellulose membranes. This method should be broadly applicable for immunochemical studies of other membrane proteins.
Flow cytomeric measurement of DNA and incorporated nucleoside analogs
Dolbeare, Frank A.; Gray, Joe W.
1989-01-01
A method is provided for simultaneously measuring total cellular DNA and incorporated nucleoside analog. The method entails altering the cellular DNA of cells grown in the presence of a nucleoside analog so that single stranded and double stranded portions are present. Separate stains are used against the two portions. An immunochemical stain is used against the single stranded portion to provide a measure of incorporated nucleoside analog, and a double strand DNA-specific stain is used against the double stranded portion to simultaneously provide a measure of total cellular DNA. The method permits rapid flow cytometric analysis of cell populations, rapid identification of cycling and noncycling subpopulations, and determination of the efficacy of S phase cytotoxic anticancer agents.
Watson, D A; Musher, D M
1990-01-01
Transposon Tn916 mutagenesis was used to produce mutant strains of Streptococcus pneumoniae serotype 3 that lacked only a polysaccharide capsule. Southern blotting, DNA-DNA hybridization, and immunochemical analyses demonstrated that the presence of a single copy of Tn916 was sufficient to produce unencapsulation. The 50% lethal dose for such mutants was greater than 5 x 10(7) CFU, as opposed to a 50% lethal dose of 1 CFU for wild-type strains. These experiments outline an effective method for targeting genes in S. pneumoniae by transposon interruption and provide molecular evidence to support the longstanding hypothesis that the capsule is the principal virulence factor in this pathogen. Images PMID:2167295
Specialized cell surface structures in cellulolytic bacteria.
Lamed, R; Naimark, J; Morgenstern, E; Bayer, E A
1987-01-01
The cell surface topology of various gram-negative and -positive, anaerobic and aerobic, mesophilic and thermophilic, cellulolytic and noncellulolytic bacteria was investigated by scanning electron microscopic visualization using cationized ferritin. Characteristic protuberant structures were observed on cells of all cellulolytic strains. These structures appeared to be directly related to the previously described exocellular cellulase-containing polycellulosomes of Clostridium thermocellum YS (E. A. Bayer and R. Lamed, J. Bacteriol. 167:828-836, 1986). Immunochemical evidence and lectin-binding studies suggested a further correlation on the molecular level among cellulolytic bacteria. The results indicate that such cell surface cellulase-containing structures may be of general consequence to the bacterial interaction with and degradation of cellulose. Images PMID:3301817
Poverennyĭ, A M; Podgorodnichenko, V K; Monastyrskaia, G S; Bryskina, L E; Sverdlov, E D
1978-01-01
Immunization of animals with DNA modified by a mixture of bisulphite and O-methylhydroxylamine and methylated bovine serum albumin results in production of antibodies mainly reacting with modified DNA. Antibodies that react with denatured DNA were produced in minute quantity. It was shown that elicited antibodies possess a high specificity and have the ability to recognize only nucleotides with a double modification. The immune sera were fractionated by Sephadex G-200 column chromatography and the antibody activity was demonstrable in the 19S and 7S fractions. The attempts to induce synthesis of antibodies by injection of DNA modified by O-methylhydroxylamine failed.
Neuropathological diagnostic criteria for Alzheimer's disease.
Murayama, Shigeo; Saito, Yuko
2004-09-01
Neuropathological diagnostic criteria for Alzheimer's disease (AD) are based on tau-related pathology: NFT or neuritic plaques (NP). The Consortium to Establish a Registry for Alzheimer's disease (CERAD) criterion evaluates the highest density of neocortical NP from 0 (none) to C (abundant). Clinical documentation of dementia and NP stage A in younger cases, B in young old cases and C in older cases fulfils the criterion of AD. The CERAD criterion is most frequently used in clinical outcome studies because of its inclusion of clinical information. Braak and Braak's criterion evaluates the density and distribution of NFT and classifies them into: I/II, entorhinal; III/IV, limbic; and V/VI, neocortical stage. These three stages correspond to normal cognition, cognitive impairment and dementia, respectively. As Braak's criterion is based on morphological evaluation of the brain alone, this criterion is usually adopted in the research setting. The National Institute for Aging and Ronald and Nancy Reagan Institute of the Alzheimer's Association criterion combines these two criteria and categorizes cases into NFT V/VI and NP C, NFT III/IV and NP B, and NFT I/II and NP A, corresponding to high, middle and low probability of AD, respectively. As most AD cases in the aged population are categorized into Braak tangle stage IV and CERAD stage C, the usefulness of this criterion has not yet been determined. The combination of Braak's NFT stage equal to or above IV and Braak's senile plaque Stage C provides, arguably, the highest sensitivity and specificity. In future, the criteria should include in vivo dynamic neuropathological data, including 3D MRI, PET scan and CSF biomarkers, as well as more sensitive and specific immunohistochemical and immunochemical grading of AD.
The Evaluator's Perspective: Evaluating the State Capacity Building Program.
ERIC Educational Resources Information Center
Madey, Doren L.
A historical antagonism between the advocates of quantitative evaluation methods and the proponents of qualitative evaluation methods has stymied the recognition of the value to be gained by utilizing both methodologies in the same study. The integration of quantitative and qualitative methods within a single evaluation has synergistic effects in…
Folded or Not? Tracking Bet v 1 Conformation in Recombinant Allergen Preparations
Seutter von Loetzen, Christian; Schweimer, Kristian; Bellinghausen, Iris; Treudler, Regina; Simon, Jan C.; Vogel, Lothar; Völker, Elke; Randow, Stefanie; Reuter, Andreas; Rösch, Paul; Vieths, Stefan; Holzhauser, Thomas; Schiller, Dirk
2015-01-01
Background Recombinant Bet v 1a (rBet v 1a) has been used in allergy research for more than three decades, including clinical application of so-called hypoallergens. Quantitative IgE binding to rBet v 1a depends on its native protein conformation, which might be compromised upon heterologous expression, purification, or mutational engineering of rBet v 1a. Objective To correlate experimental/theoretical comparisons of IgE binding of defined molar ratios of folded/misfolded recombinant Bet v 1a variants and to determine accuracy and precision of immuno- and physicochemical assays routinely used to assess the quality of recombinant allergen preparations. Methods rBet v 1a and its misfolded variant rBet v 1aS112P/R145P were heterologously expressed and purified from Escherichia coli. Structural integrities and oligomerisation of the recombinant allergens were evaluated by 1H-nuclear magnetic resonance (1H-NMR), circular dichroism (CD) spectroscopy, and dynamic light scattering (DLS). IgE binding of defined combinations of rBet v 1a and rBet v 1aS112P/R145P was assessed using immunoblotting (IB), enzyme-linked immunosorbent assay (ELISA) and mediator release (MR) of humanized rat basophilic leukemia cells sensitized with serum IgE of subjects allergic to birch pollen. Experimental and theoretically expected results of the analyses were compared. Results 1H-NMR spectra of rBet v 1a and rBet v 1aS112P/R145P demonstrate a native and highly disordered protein conformations, respectively. The CD spectra suggested typical alpha-helical and beta-sheet secondary structure content of rBet v 1a and random coil for rBet v 1aS112P/R145P. The hydrodynamic radii (RH) of 2.49 ± 0.39 nm (rBet v 1a) and 3.1 ± 0.56 nm (rBet v 1aS112P/R145P) showed monomeric dispersion of both allergens in solution. Serum IgE of birch pollen allergic subjects bound to 0.1% rBet v 1a in the presence of 99.9% of non-IgE binding rBet v 1aS112P/R145P. Immunoblot analysis overestimated, whereas ELISA and mediator release assay underestimated the actual quantity of IgE-reactive rBet v 1a in mixtures of rBet v 1a/rBet v 1aS112P/R145P with a molar ratio of rBet v 1a ≤ 10%. Conclusion Valid conclusions on quantitative IgE binding of recombinant Bet v 1a preparations depend on the accuracy and precision of physico- and immunochemical assays with which natively folded allergen is detected. PMID:26186356
Fernandez-Rozadilla, Ceres; Kartsonaki, Christiana; Woolley, Connor; McClellan, Michael; Whittington, Deb; Horgan, Gareth; Leedham, Simon; Kriaucionis, Skirmantas; East, James; Tomlinson, Ian
2018-03-06
Colorectal cancer (CRC) screening might be improved by using a measure of prior risk to modulate screening intensity or the faecal immunochemical test threshold. Intermediate molecular biomarkers could aid risk prediction by capturing both known and unknown risk factors. We sampled normal bowel mucosa from the proximal colon, distal colon and rectum of 317 individuals undergoing colonoscopy. We defined cases as having a personal history of colorectal polyp(s)/cancer, and controls as having no history of colorectal neoplasia. Molecular analyses were performed for: telomere length (TL); global methylation; and the expression of genes in molecular pathways associated with colorectal tumourigenesis. We also calculated a polygenic risk score (PRS) based on CRC susceptibility polymorphisms. Bowel TL was significantly longer in cases than controls, but was not associated with blood TL. PRS was significantly and independently higher in cases. Hypermethylation showed a suggestive association with case:control status. No gene or pathway was differentially expressed between cases and controls. Gene expression often varied considerably between bowel locations. PRS and bowel TL (but not blood TL) may be clinically-useful predictors of CRC risk. Sample collection to assess these biomarkers is feasible in clinical practice, especially where population screening uses flexible sigmoidoscopy or colonoscopy.
Proteomic analysis of the major birch allergen Bet v 1 predicts allergenicity for 15 birch species.
Schenk, Martijn F; Cordewener, Jan H G; America, Antoine H P; Peters, Jeroen; Smulders, Marinus J M; Gilissen, Luud J W J
2011-08-12
Pollen of the European and Asian white birch (Betula pendula and B. platyphylla) causes hay fever in humans. The allergenic potency of other birch species is largely unknown. To identify birch trees with a reduced allergenicity, we assessed the immunochemical characteristics of 15 species and two hybrids, representing four subgenera within the genus Betula, while focusing on the major pollen allergen Bet v 1. Antigenic and allergenic profiles of pollen extracts from these species were evaluated by SDS-PAGE and Western blot using pooled sera of birch-allergic individuals. Tryptic digests of the Bet v 1 bands were analyzed by LC-MS(E) to determine the abundance of various Bet v 1 isoforms. Bet v 1 was the most abundant pollen protein across all birch species. LC-MS(E) confirmed that pollen of all species contained a mixture of multiple Bet v 1 isoforms. Considerable differences in Bet v 1 isoform composition exist between birch species. However, isoforms that are predicted to have a high IgE-reactivity prevailed in pollen of all species. Immunoblotting confirmed that all pollen extracts were similar in immune-reactivity, implying that pollen of all birch species is likely to evoke strong allergic reactions. Copyright © 2011 Elsevier B.V. All rights reserved.
Song, Lele; Jia, Jia; Peng, Xiumei; Xiao, Wenhua; Li, Yuemin
2017-06-08
The SEPT9 gene methylation assay is the first FDA-approved blood assay for colorectal cancer (CRC) screening. Fecal immunochemical test (FIT), FIT-DNA test and CEA assay are also in vitro diagnostic (IVD) tests used in CRC screening. This meta-analysis aims to review the SEPT9 assay performance and compare it with other IVD CRC screening tests. By searching the Ovid MEDLINE, EMBASE, CBMdisc and CJFD database, 25 out of 180 studies were identified to report the SEPT9 assay performance. 2613 CRC cases and 6030 controls were included, and sensitivity and specificity were used to evaluate its performance at various algorithms. 1/3 algorithm exhibited the best sensitivity while 2/3 and 1/1 algorithm exhibited the best balance between sensitivity and specificity. The performance of the blood SEPT9 assay is superior to that of the serum protein markers and the FIT test in symptomatic population, while appeared to be less potent than FIT and FIT-DNA tests in asymptomatic population. In conclusion, 1/3 algorithm is recommended for CRC screening, and 2/3 or 1/1 algorithms are suitable for early detection for diagnostic purpose. The SEPT9 assay exhibited better performance in symptomatic population than in asymptomatic population.
Säll, Anna; Walle, Maria; Wingren, Christer; Müller, Susanne; Nyman, Tomas; Vala, Andrea; Ohlin, Mats; Borrebaeck, Carl A K; Persson, Helena
2016-10-01
Antibody-based proteomics offers distinct advantages in the analysis of complex samples for discovery and validation of biomarkers associated with disease. However, its large-scale implementation requires tools and technologies that allow development of suitable antibody or antibody fragments in a high-throughput manner. To address this we designed and constructed two human synthetic antibody fragment (scFv) libraries denoted HelL-11 and HelL-13. By the use of phage display technology, in total 466 unique scFv antibodies specific for 114 different antigens were generated. The specificities of these antibodies were analyzed in a variety of immunochemical assays and a subset was further evaluated for functionality in protein microarray applications. This high-throughput approach demonstrates the ability to rapidly generate a wealth of reagents not only for proteome research, but potentially also for diagnostics and therapeutics. In addition, this work provides a great example on how a synthetic approach can be used to optimize library designs. By having precise control of the diversity introduced into the antigen-binding sites, synthetic libraries offer increased understanding of how different diversity contributes to antibody binding reactivity and stability, thereby providing the key to future library optimization. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-11
... quantitative research and evaluation process that forecasts economic excess sector returns (over/under the... proprietary SectorSAM quantitative research and evaluation process. \\8\\ The following convictions constitute... Allocation Methodology'' (``SectorSAM''), which is a proprietary quantitative analysis, to forecast each...
Peng, Qiyu; Park, Hyung-Soon; Shah, Parag; Wilson, Nicole; Ren, Yupeng; Wu, Yi-Ning; Liu, Jie; Gaebler-Spira, Deborah J; Zhang, Li-Qun
2011-01-01
Spasticity and contracture are major sources of disability in people with neurological impairments that have been evaluated using various instruments: the Modified Ashworth Scale, tendon reflex scale, pendulum test, mechanical perturbations, and passive joint range of motion (ROM). These measures generally are either convenient to use in clinics but not quantitative or they are quantitative but difficult to use conveniently in clinics. We have developed a manual spasticity evaluator (MSE) to evaluate spasticity/contracture quantitatively and conveniently, with ankle ROM and stiffness measured at a controlled low velocity and joint resistance and Tardieu catch angle measured at several higher velocities. We found that the Tardieu catch angle was linearly related to the velocity, indicating that increased resistance at higher velocities was felt at further stiffer positions and, thus, that the velocity dependence of spasticity may also be position-dependent. This finding indicates the need to control velocity in spasticity evaluation, which is achieved with the MSE. Quantitative measurements of spasticity, stiffness, and ROM can lead to more accurate characterizations of pathological conditions and outcome evaluations of interventions, potentially contributing to better healthcare services for patients with neurological disorders such as cerebral palsy, spinal cord injury, traumatic brain injury, and stroke.
Guerra, Luciano Lucas; Faccinetti, Natalia Inés; Trabucchi, Aldana; Rovitto, Bruno David; Sabljic, Adriana Victoria; Poskus, Edgardo; Iacono, Ruben Francisco; Valdez, Silvina Noemí
2016-11-24
The insulinoma associated protein tyrosine phosphatase 2 (IA-2) is one of the immunodominant autoantigens involved in the autoimmune attack to the beta-cell in Type 1 Diabetes Mellitus. In this work we have developed a complete and original process for the production and recovery of the properly folded intracellular domain of IA-2 fused to thioredoxin (TrxIA-2 ic ) in Escherichia coli GI698 and GI724 strains. We have also carried out the biochemical and immunochemical characterization of TrxIA-2 ic and design variants of non-radiometric immunoassays for the efficient detection of IA-2 autoantibodies (IA-2A). The main findings can be summarized in the following statements: i) TrxIA-2 ic expression after 3 h of induction on GI724 strain yielded ≈ 10 mg of highly pure TrxIA-2 ic /L of culture medium by a single step purification by affinity chromatography, ii) the molecular weight of TrxIA-2 ic (55,358 Da) could be estimated by SDS-PAGE, size exclusion chromatography and mass spectrometry, iii) TrxIA-2 ic was properly identified by western blot and mass spectrometric analysis of proteolytic digestions (63.25 % total coverage), iv) excellent immunochemical behavior of properly folded full TrxIA-2 ic was legitimized by inhibition or displacement of [ 35 S]IA-2 binding from IA-2A present in Argentinian Type 1 Diabetic patients, v) great stability over time was found under proper storage conditions and vi) low cost and environmentally harmless ELISA methods for IA-2A assessment were developed, with colorimetric or chemiluminescent detection. E. coli GI724 strain emerged as a handy source of recombinant IA-2 ic , achieving high levels of expression as a thioredoxin fusion protein, adequately validated and applicable to the development of innovative and cost-effective immunoassays for IA-2A detection in most laboratories.
Pecetta, S; Lo Surdo, P; Tontini, M; Proietti, D; Zambonelli, C; Bottomley, M J; Biagini, M; Berti, F; Costantino, P; Romano, M R
2015-01-03
Glycoconjugate vaccines play an enormous role in preventing infectious diseases. The main carrier proteins used in commercial conjugate vaccines are the non-toxic mutant of diphtheria toxin (CRM197), diphtheria toxoid (DT) and tetanus toxoid (TT). Modern childhood routine vaccination schedules include the administration of several vaccines simultaneously or in close sequence, increasing the concern that the repeated exposure to conjugates based on these carrier proteins might interfere with the anti-polysaccharide response. Extending previous observations we show here that priming mice with CRM197 or DT does not suppress the response to the carbohydrate moiety of CRM197 meningococcal serogroup A (MenA) conjugates, while priming with DT can suppress the response to DT-MenA conjugates. To explain these findings we made use of biophysical and immunochemical techniques applied mainly to MenA conjugates. Differential scanning calorimetry and circular dichroism data revealed that the CRM197 structure was altered by the chemical conjugation, while DT and the formaldehyde-treated form of CRM197 were less impacted, depending on the degree of glycosylation. Investigating the binding and avidity properties of IgGs induced in mice by non-conjugated carriers, we found that CRM197 induced low levels of anti-carrier antibodies, with decreased avidity for its MenA conjugates and poor binding to DT and respective MenA conjugates. In contrast, DT induced high antibody titers able to bind with comparable avidity both the protein and its conjugates but showing very low avidity for CRM197 and related conjugates. The low intrinsic immunogenicity of CRM197 as compared to DT, the structural modifications induced by glycoconjugation and detoxification processes, resulting in conformational changes in CRM197 and DT epitopes with consequent alteration of the antibody recognition and avidity, might explain the different behavior of CRM197 and DT in a carrier priming context. Copyright © 2014 Elsevier Ltd. All rights reserved.
Liao, Yi; Li, Senmao; Chen, Chunyu; He, Xuan; Lin, Feng; Wang, Jianping; Yang, Zuli; Lan, Ping
2018-05-01
To explore the performance of a protocol combining fecal immunochemical test (FIT) and a high-risk factor questionnaire (HRFQ) for selecting patients requiring colonoscopy as part of a population-based colorectal cancer (CRC) screening program in China. From 2015 to 2016, we conducted a CRC screening program for all residents aged 45 years or older in Tianhe District, Guangzhou City, China. Participants underwent an FIT and received an HRFQ as part of primary screening. Those with positive FIT and/or HRFQ results were considered to be at high risk and were recommended to undergo colonoscopy. A total of 10 074 subjects were recruited and enrolled in the screening program. In the enrolled population, 17.5% had positive FIT results and 19.4% had positive HRFQ results. Of those recommended to undergo diagnostic colonoscopy, 773 did so. The screening method's overall positive predictive value (PPV) was 4.9% for non-adenomatous polyps, 11.4% for low-risk adenomas (LRAs), 15.9% for high-risk adenomas (HRAs) and 1.6% for CRC. The PPVs of positive FIT results for non-adenomatous polyps, LRAs, HRAs and CRC were 5.2%, 15.9%, 22.5% and 2.5%, respectively. The PPVs of positive HRFQ results for non-adenomatous polyps, LRA, HRA and CRC were 4.1%, 10.2%, 14.3% and 1.4%, respectively. The PPVs associated with combined positive FIT and HRFQ results for non-adenomatous polyps, LRAs, HRAs and CRC were 4.5%, 16.4%, 23.7% and 2.8%, respectively. Our results suggest that this two-step CRC screening strategy, involving a combination of FIT and HRFQ followed by colonoscopy, is useful to identify early-stage CRC. The high detection rates and PPVs for CRC and adenomas encourage this strategy's use in ongoing screening programs.
Nieuwenburg, Stella A V; Vuik, Fanny E R; Kruip, Marieke J H A; Kuipers, Ernst J; Spaander, Manon C W
2018-06-05
Most colorectal cancer (CRC) screening programmes are nowadays based on faecal immunochemical testing (FIT). Eligible subjects often use oral anticoagulants (OACs) or non-steroidal anti-inflammatory drugs (NSAIDs), which could possibly stimulate bleeding from both benign and premalignant lesions in the colon. The aim of this meta-analysis was to study the effect of OACs and NSAIDs use on FIT performance. A systematic search was conducted until June 2017 to retrieve studies from PubMed, Embase, MEDLINE, Web of science, Cochrane Central and Google Scholar. Studies were included when reporting on FIT results in users versus non-users of OACs and/or NSAIDs in average risk CRC screening populations. Primary outcome was positive predictive value for advanced neoplasia (PPV AN ) of FIT in relation to OACs/NSAIDs use. Values were obtained by conducting random-effect forest plots. Our literature search identified 2022 records, of which 8 studies were included. A total of 3563 participants with a positive FIT were included. Use of OACs was associated with a PPV AN of 37.6% (95% CI 33.9 to 41.4) compared with 40.3% (95% CI 38.5 to 42.1) for non-users (p=0.75). Pooled PPV AN in aspirin/NSAID users was 38.2% (95% CI 33.8 to 42.9) compared with 39.4% (95% CI 37.5 to 41.3) for non-users (p=0.59). FIT accuracy is not affected by OACs and aspirin/NSAIDs use. Based on the current literature, withdrawal of OACs or NSAIDs before FIT screening is not recommended. Future studies should focus on duration of use, dosage and classes of drugs in association with accuracy of FIT to conduct more specific guideline recommendations. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Ting, Po-Hsiang; Lin, Xi-Hsuan; Jiang, Jeng-Kai; Luo, Jiing-Chyuan; Chen, Ping-Hsien; Wang, Yen-Po; Hsin, I-Fang; Perng, Chin Lin; Hou, Ming-Chih; Lee, Fa-Yauh
2018-05-16
The immunochemical fecal occult blood test (iFOBT) is an alternative method to colonoscopy that can be used for colorectal cancer (CRC) screening. If the iFOBT result is positive, a colonoscopy is recommended. In this retrospective study, we identify factors associated with negative colonoscopy and positive iFOBT results obtained during CRC screening. We collected data for subjects who received a colonoscopy at Taipei Veterans General Hospital after receiving a positive iFOBT result during CRC screening from January 2015 to December 2015. Subjects' baseline data, medications, and co-morbidities as well as colonoscopy and histological findings were recorded. A negative colonoscopy result was defined as no detection of any colorectal neoplasia including non-advanced adenoma, advanced adenoma, and adenocarciona. Multivariate logistic regression analysis was conducted to identify the associated factors in screening subjects with positive iFOBT but negative colonoscopy results. 559 (46.3%) out of 1207 eligible study subjects received a colonoscopy with a negative result. Multivariate logistic regression analysis revealed that the use of antiplatelets [odds ratio (OR) = 0.654; 95% confidence interval (CI), 0.434-0.986], occurrence of hemorrhoid (OR = 0.595; 95% CI, 0.460-0.768), and the existence of colitis/ulcer (OR = 0.358; 95% CI, 0.162-0.789) were independent factors associated with negative colonoscopy but positive iFOBT results during CRC screening. The colon clean level, underlying diseases of gastrointestinal bleeding tendency (e.g., chronic kidney disease, cirrhosis), and the use of anticoagulant or nonsteroidal anti-inflammatory agents were not associated with negative colonoscopy and positive iFOBT results. The use of antiplatelet agents and the presence of hemorrhoids and colitis/ulcers were factors associated with negative colonoscopy and positive iFOBT results. Copyright © 2018. Published by Elsevier Taiwan LLC.
Johnson, David A.; Barclay, Robert L.; Mergener, Klaus; Weiss, Gunter; König, Thomas; Beck, Jürgen; Potter, Nicholas T.
2014-01-01
Background Screening improves outcomes related to colorectal cancer (CRC); however, suboptimal participation for available screening tests limits the full benefits of screening. Non-invasive screening using a blood based assay may potentially help reach the unscreened population. Objective To compare the performance of a new Septin9 DNA methylation based blood test with a fecal immunochemical test (FIT) for CRC screening. Design: In this trial, fecal and blood samples were obtained from enrolled patients. To compare test sensitivity for CRC, patients with screening identified colorectal cancer (n = 102) were enrolled and provided samples prior to surgery. To compare test specificity patients were enrolled prospectively (n = 199) and provided samples prior to bowel preparation for screening colonoscopy. Measurements Plasma and fecal samples were analyzed using the Epi proColon and OC Fit-Check tests respectively. Results For all samples, sensitivity for CRC detection was 73.3% (95% CI 63.9–80.9%) and 68.0% (95% CI 58.2–76.5%) for Septin9 and FIT, respectively. Specificity of the Epi proColon test was 81.5% (95% CI 75.5–86.3%) compared with 97.4% (95% CI 94.1–98.9%) for FIT. For paired samples, the sensitivity of the Epi proColon test (72.2% –95% CI 62.5–80.1%) was shown to be statistically non-inferior to FIT (68.0%–95% CI 58.2–76.5%). When test results for Epi proColon and FIT were combined, CRC detection was 88.7% at a specificity of 78.8%. Conclusions At a sensitivity of 72%, the Epi proColon test is non- inferior to FIT for CRC detection, although at a lower specificity. With negative predictive values of 99.8%, both methods are identical in confirming the absence of CRC. Trial Registration ClinicalTrials.gov NCT01580540 PMID:24901436
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-23
... has developed a proprietary SectorSAM \\TM\\ quantitative research and evaluation process that forecasts... and short portfolios as dictated by its proprietary SectorSAM quantitative research and evaluation... a proprietary quantitative analysis, to forecast each sector's excess return within a specific time...
Quantitative evaluation methods of skin condition based on texture feature parameters.
Pang, Hui; Chen, Tianhua; Wang, Xiaoyi; Chang, Zhineng; Shao, Siqi; Zhao, Jing
2017-03-01
In order to quantitatively evaluate the improvement of the skin condition after using skin care products and beauty, a quantitative evaluation method for skin surface state and texture is presented, which is convenient, fast and non-destructive. Human skin images were collected by image sensors. Firstly, the median filter of the 3 × 3 window is used and then the location of the hairy pixels on the skin is accurately detected according to the gray mean value and color information. The bilinear interpolation is used to modify the gray value of the hairy pixels in order to eliminate the negative effect of noise and tiny hairs on the texture. After the above pretreatment, the gray level co-occurrence matrix (GLCM) is calculated. On the basis of this, the four characteristic parameters, including the second moment, contrast, entropy and correlation, and their mean value are calculated at 45 ° intervals. The quantitative evaluation model of skin texture based on GLCM is established, which can calculate the comprehensive parameters of skin condition. Experiments show that using this method evaluates the skin condition, both based on biochemical indicators of skin evaluation methods in line, but also fully consistent with the human visual experience. This method overcomes the shortcomings of the biochemical evaluation method of skin damage and long waiting time, also the subjectivity and fuzziness of the visual evaluation, which achieves the non-destructive, rapid and quantitative evaluation of skin condition. It can be used for health assessment or classification of the skin condition, also can quantitatively evaluate the subtle improvement of skin condition after using skin care products or stage beauty.
The Numbers Tell It All: Students Don't Like Numbers!
Uttl, Bob; White, Carmela A.; Morin, Alain
2013-01-01
Undergraduate Students' interest in taking quantitative vs. non quantitative courses has received limited attention even though it has important consequences for higher education. Previous studies have collected course interest ratings at the end of the courses as part of student evaluation of teaching (SET) ratings, which may confound prior interest in taking these courses with students' actual experience in taking them. This study is the first to examine undergraduate students' interest in quantitative vs. non quantitative courses in their first year of studies before they have taken any quantitative courses. Three hundred and forty students were presented with descriptions of 44 psychology courses and asked to rate their interest in taking each course. Student interest in taking quantitative vs non quantitative courses was very low; the mean interest in statistics courses was nearly 6 SDs below the mean interest in non quantitative courses. Moreover, women were less interested in taking quantitative courses than men. Our findings have several far-reaching implications. First, evaluating professors teaching quantitative vs. non quantitative courses against the same SET standard may be inappropriate. Second, if the same SET standard is used for the evaluation of faculty teaching quantitative vs. non quantitative courses, faculty are likely to teach to SETs rather than focus on student learning. Third, universities interested primarily in student satisfaction may want to expunge quantitative courses from their curricula. In contrast, universities interested in student learning may want to abandon SETs as a primary measure of faculty teaching effectiveness. Fourth, undergraduate students who are not interested in taking quantitative courses are unlikely to pursue graduate studies in quantitative psychology and unlikely to be able to competently analyze data independently. PMID:24358284
NASA Astrophysics Data System (ADS)
shunhe, Li; jianhua, Rao; lin, Gui; weimin, Zhang; degang, Liu
2017-11-01
The result of remanufacturing evaluation is the basis for judging whether the heavy duty machine tool can remanufacture in the EOL stage of the machine tool lifecycle management.The objectivity and accuracy of evaluation is the key to the evaluation method.In this paper, the catastrophe progression method is introduced into the quantitative evaluation of heavy duty machine tools’ remanufacturing,and the results are modified by the comprehensive adjustment method,which makes the evaluation results accord with the standard of human conventional thinking.Using the catastrophe progression method to establish the heavy duty machine tools’ quantitative evaluation model,to evaluate the retired TK6916 type CNC floor milling-boring machine’s remanufacturing.The evaluation process is simple,high quantification,the result is objective.
Rota, Cristina; Biondi, Marco; Trenti, Tommaso
2011-09-26
Aution Max AX-4030, a test strip analyzer recently introduced to the market, represents an upgrade of the Aution Max AX-4280 widely employed for urinalysis. This new instrument model can allocate two different test strips at the same time. In the present study the two instruments have been compared together with the usage of Uriflet 9UB and the recently produced Aution Sticks 10PA urine strips, the latter presenting an additional test area for the measurement of urinary creatinine. Imprecision and correlation between instruments and strips have been evaluated for chemical-physical parameters. Accuracy was evaluated for protein, glucose and creatinine by comparing the semi-quantitative results to those obtained by quantitative methods. The well-known interference effect of high ascorbic acid levels on urine glucose test strip determination was evaluated, ascorbic acid influence was also evaluated on protein and creatinine determination. The two instruments have demonstrated comparable performances: precision and correlation between instruments and strips, evaluated for chemical-physical parameters, were always good. Furthermore, accuracy was always very good: results of protein and glucose semi-quantitative measurements resulted to be highly correlated with those obtained by quantitative methods. Moreover, the semi-quantitative measurements of creatinine, employing Aution Sticks 10PA urine strips, were highly comparable with quantitative results. 10PA urine strips are eligible for urine creatinine determination with the possibility of correcting urinalysis results for urinary creatinine concentration, whenever necessary and calculating the protein creatinine ratio. Further studies should be carried out to evaluate effectiveness and appropriateness of the usage of creatinine semi-quantitative analysis.
2012-01-01
Background Colorectal cancer (CRC) screening requires sufficient endoscopic resources. The present study aims to determine the Dutch endoscopic production and manpower for 2009, evaluate trends since 2004, determine additional workload which would be caused by implementation of a CRC screening program, and inventory colonoscopy rates performed in other European countries. Methods All Dutch endoscopy units (N = 101) were surveyed for manpower and the numbers of endoscopy procedures performed in 2009. Based on calculations in the report issued by the Dutch Health Council, future additional workload caused by faecal immunochemical test (FIT) screening was estimated. The number of colonoscopies performed in Europe was evaluated by a literature search and an email-inquiry. Results Compared to 2004, there was a 24% increase in total endoscopies (N = 505,226 in 2009), and a 64% increase in colonoscopies (N = 191,339 in 2009) in The Netherlands. The number of endoscopists had increased by 4.6% (N = 583 in 2009). Five years after stepwise implementation of FIT-based CRC screening, endoscopic capacity needs to be increased an additional 15%. A lack of published data on the number of endoscopies performed in Europe was found. Based on our email-inquiry, the number of colonoscopies per 100,000 inhabitants ranged from 126 to 3,031 in 15 European countries. Conclusions Over the last years, endoscopic procedures increased markedly in The Netherlands without a corresponding increase in manpower. A FIT-based CRC screening program requires an estimated additional 15% increase in endoscopic procedures. It is very likely that current colonoscopy density varies widely across European countries. PMID:22280408
Primary mucosal malignant melanoma of the cervix: case report and review of the literature.
Cetinkaya, Kadir; Benzer, Emine; Dervisoglu, Haluk
2015-09-09
The incidence of primary mucosal malignant melanoma (PMMM) is 1.3% among all malignant melanomas (MM). Cervical involvement is very rare; the number of cases of cervical PMMM reported so far is around 80. In our patient, a dark color, 2-cm diameter, nonulcerated tumor formation was observed upon examination of the cervix. Tumoral tissue consisted of atypical melanocytic cells containing numerous mitotic figures. In immunochemical studies, S-100, Melan-A, and HMB-45 positivity were observed. The tumor was 20 mm in invasion depth, Breslow IV, and FIGO stage IB1. Radical surgery was followed by adjuvant radiotherapy, and subsequently interferon treatment was applied. Examination and scans 20 months after surgery were free from tumor.
Analytical methods for gelatin differentiation from bovine and porcine origins and food products.
Nhari, Raja Mohd Hafidz Raja; Ismail, Amin; Che Man, Yaakob B
2012-01-01
Usage of gelatin in food products has been widely debated for several years, which is about the source of gelatin that has been used, religion, and health. As an impact, various analytical methods have been introduced and developed to differentiate gelatin whether it is made from porcine or bovine sources. The analytical methods comprise a diverse range of equipment and techniques including spectroscopy, chemical precipitation, chromatography, and immunochemical. Each technique can differentiate gelatins for certain extent with advantages and limitations. This review is focused on overview of the analytical methods available for differentiation of bovine and porcine gelatin and gelatin in food products so that new method development can be established. © 2011 Institute of Food Technologists®
Jiménez-Ayala, M; Díez-Nau, M D; Larrad, A; Ferrer-Vergara, L; Rodriguez-Costa, J; Lacruz, C; Escalona-Zapata, J
1991-01-01
A hemangiopericytoma in a male breast was studied by fine needle aspiration (FNA) biopsy. The FNA smears contained tissue clumps showing knob-like formations of atypical cells, spindle-shaped cells and fragments of capillaries lined by normal endothelial cells. Immunocytochemical study showed a positive reaction for vimentin, but a negative reaction for desmin and keratin. Staining for Factor VIII was positive only in the capillaries and endothelial cells. The cytodiagnosis was "mesenchymal tumor." Histopathologic study of the mastectomy specimen made the final diagnosis of hemangiopericytoma. While FNA cytology and immunocytochemistry cannot make a definitive diagnosis of this rare vascular tumor, they can be decisive in planning the surgical treatment, as in the present case.
Willott, E; Trenczek, T; Thrower, L W; Kanost, M R
1994-12-01
We have made 140 monoclonal antibodies to hemocytes (insect blood cells) from Manduca sexta. Four of these antibodies, when used in immunofluorescent microscopy of fixed hemocytes, distinguish the four main morphologically distinct hemocyte types. Plasmatocytes, granular cells, and oenocytoids are each recognized by a unique antibody specific to that type; spherulocytes are recognized by an antibody that also binds to plasmatocytes. When used in flow cytometry with nonfixed hemocytes, three of the four antibodies bind their respective cells; the oenocytoid marker failed to bind to any hemocytes. This set of four monoclonal antibodies may be useful for labeling individual cell types and for separating the different hemocyte types for further study of hemocyte functions.
[Characterization of a human cell line from an anaplastic carcinoma of the thyroid gland].
Gioanni, J; Zanghellini, E; Mazeau, C; Zhang, D; Courdi, A; Farges, M; Lambert, J C; Duplay, H; Schneider, M
1991-11-01
A new cell line derived from a thyroid anaplastic carcinoma, CAL 62, has been established in culture. This line is constituted by highly tumorigenic cells. Their epithelial phenotype is stable in culture. Immunochemical staining for human thyroglobulin is negative. Cytogenetic analysis showed a gain of chromosome 20, the translocation i (14q), and breakpoints of centrometric chromatine. These results are similar to those previously reported by other investigators. CAL 62 radiosensibility has been studied. The survival curve of the in vitro irradiated cells has been adjusted with a linear-quadratic model. This cell line is thus showed to be radioresistant. Cell line CAL 62 constitutes an appropriate model for in vitro studies of thyroid anaplastic carcinoma.
Obama, K; Tara, M; Niina, K
1999-06-01
A 30-year-old man was admitted to our hospital with subcutaneous tumors and a high fever. Based on biomicroscopic findings of the tumor, the patient was diagnosed as having diffuse, medium, well-differentiated malignant lymphoma. Immunochemical analysis showed that CD3, CD4, CD25, and TCR beta were positive, and in situ hybridization revealed Epstein-Barr virus-encoded small RNAs in the nuclei of the lymphoma cells. Despite the patient's resistance to multidrug therapy, complete remission was achieved using L-asparaginase. This case is unique because of its peculiar clinical course and a possible association with the Epstein-Barr virus. L-asparaginase may be an important treatment in other patients who exhibit some of these characteristics.
Composition of extracts of airborne grain dusts: lectins and lymphocyte mitogens.
Olenchock, S A; Lewis, D M; Mull, J C
1986-01-01
Airborne grain dusts are heterogeneous materials that can elicit acute and chronic respiratory pathophysiology in exposed workers. Previous characterizations of the dusts include the identification of viable microbial contaminants, mycotoxins, and endotoxins. We provide information on the lectin-like activity of grain dust extracts and its possible biological relationship. Hemagglutination of erythrocytes and immunochemical modulation by antibody to specific lectins showed the presence of these substances in extracts of airborne dusts from barley, corn, and rye. Proliferation of normal rat splenic lymphocytes in vitro provided evidence for direct biological effects on the cells of the immune system. These data expand the knowledge of the composition of grain dusts (extracts), and suggest possible mechanisms that may contribute to respiratory disease in grain workers. PMID:3709474
[Isolation and identification methods of enterobacteria group and its technological advancement].
Furuta, Itaru
2007-08-01
In the last half-century, isolation and identification methods of enterobacteria groups have markedly improved by technological advancement. Clinical microbiology tests have changed overtime from tube methods to commercial identification kits and automated identification. Tube methods are the original method for the identification of enterobacteria groups, that is, a basically essential method to recognize bacterial fermentation and biochemical principles. In this paper, traditional tube tests are discussed, such as the utilization of carbohydrates, indole, methyl red, and citrate and urease tests. Commercial identification kits and automated instruments by computer based analysis as current methods are also discussed, and those methods provide rapidity and accuracy. Nonculture techniques of nucleic acid typing methods using PCR analysis, and immunochemical methods using monoclonal antibodies can be further developed.
Evaluation of background parenchymal enhancement on breast MRI: a systematic review
Signori, Alessio; Valdora, Francesca; Rossi, Federica; Calabrese, Massimo; Durando, Manuela; Mariscotto, Giovanna; Tagliafico, Alberto
2017-01-01
Objective: To perform a systematic review of the methods used for background parenchymal enhancement (BPE) evaluation on breast MRI. Methods: Studies dealing with BPE assessment on breast MRI were retrieved from major medical libraries independently by four reviewers up to 6 October 2015. The keywords used for database searching are “background parenchymal enhancement”, “parenchymal enhancement”, “MRI” and “breast”. The studies were included if qualitative and/or quantitative methods for BPE assessment were described. Results: Of the 420 studies identified, a total of 52 articles were included in the systematic review. 28 studies performed only a qualitative assessment of BPE, 13 studies performed only a quantitative assessment and 11 studies performed both qualitative and quantitative assessments. A wide heterogeneity was found in the MRI sequences and in the quantitative methods used for BPE assessment. Conclusion: A wide variability exists in the quantitative evaluation of BPE on breast MRI. More studies focused on a reliable and comparable method for quantitative BPE assessment are needed. Advances in knowledge: More studies focused on a quantitative BPE assessment are needed. PMID:27925480
Code of Federal Regulations, 2013 CFR
2013-01-01
..., a “measurement” shall be defined as an evaluation where quantitative data is obtained (e.g... evaluation where no quantitative data is obtained (e.g., a check mark indicating conformance is usually the...
Code of Federal Regulations, 2014 CFR
2014-01-01
..., a “measurement” shall be defined as an evaluation where quantitative data is obtained (e.g... evaluation where no quantitative data is obtained (e.g., a check mark indicating conformance is usually the...
Code of Federal Regulations, 2010 CFR
2010-01-01
..., a “measurement” shall be defined as an evaluation where quantitative data is obtained (e.g... evaluation where no quantitative data is obtained (e.g., a check mark indicating conformance is usually the...
Code of Federal Regulations, 2012 CFR
2012-01-01
..., a “measurement” shall be defined as an evaluation where quantitative data is obtained (e.g... evaluation where no quantitative data is obtained (e.g., a check mark indicating conformance is usually the...
Code of Federal Regulations, 2011 CFR
2011-01-01
..., a “measurement” shall be defined as an evaluation where quantitative data is obtained (e.g... evaluation where no quantitative data is obtained (e.g., a check mark indicating conformance is usually the...
Online versus Paper Evaluations: Differences in Both Quantitative and Qualitative Data
ERIC Educational Resources Information Center
Burton, William B.; Civitano, Adele; Steiner-Grossman, Penny
2012-01-01
This study sought to determine if differences exist in the quantitative and qualitative data collected with paper and online versions of a medical school clerkship evaluation form. Data from six-and-a-half years of clerkship evaluations were used, some collected before and some after the conversion from a paper to an online evaluation system. The…
Addison, Prue F E; Flander, Louisa B; Cook, Carly N
2017-08-01
Protected area management effectiveness (PAME) evaluation is increasingly undertaken to evaluate governance, assess conservation outcomes and inform evidence-based management of protected areas (PAs). Within PAME, quantitative approaches to assess biodiversity outcomes are now emerging, where biological monitoring data are directly assessed against quantitative (numerically defined) condition categories (termed quantitative condition assessments). However, more commonly qualitative condition assessments are employed in PAME, which use descriptive condition categories and are evaluated largely with expert judgement that can be subject to a range of biases, such as linguistic uncertainty and overconfidence. Despite the benefits of increased transparency and repeatability of evaluations, quantitative condition assessments are rarely used in PAME. To understand why, we interviewed practitioners from all Australian marine protected area (MPA) networks, which have access to long-term biological monitoring data and are developing or conducting PAME evaluations. Our research revealed that there is a desire within management agencies to implement quantitative condition assessment of biodiversity outcomes in Australian MPAs. However, practitioners report many challenges in transitioning from undertaking qualitative to quantitative condition assessments of biodiversity outcomes, which are hampering progress. Challenges include a lack of agency capacity (staff numbers and money), knowledge gaps, and diminishing public and political support for PAs. We point to opportunities to target strategies that will assist agencies overcome these challenges, including new decision support tools, approaches to better finance conservation efforts, and to promote more management relevant science. While a single solution is unlikely to achieve full evidence-based conservation, we suggest ways for agencies to target strategies and advance PAME evaluations toward best practice. Copyright © 2017 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Teater, Barbra; Roy, Jessica; Carpenter, John; Forrester, Donald; Devaney, John; Scourfield, Jonathan
2017-01-01
Students in the United Kingdom (UK) are found to lack knowledge and skills in quantitative research methods. To address this gap, a quantitative research method and statistical analysis curriculum comprising 10 individual lessons was developed, piloted, and evaluated at two universities The evaluation found that BSW students' (N = 81)…
Quantitative Muscle Ultrasonography in Carpal Tunnel Syndrome.
Lee, Hyewon; Jee, Sungju; Park, Soo Ho; Ahn, Seung-Chan; Im, Juneho; Sohn, Min Kyun
2016-12-01
To assess the reliability of quantitative muscle ultrasonography (US) in healthy subjects and to evaluate the correlation between quantitative muscle US findings and electrodiagnostic study results in patients with carpal tunnel syndrome (CTS). The clinical significance of quantitative muscle US in CTS was also assessed. Twenty patients with CTS and 20 age-matched healthy volunteers were recruited. All control and CTS subjects underwent a bilateral median and ulnar nerve conduction study (NCS) and quantitative muscle US. Transverse US images of the abductor pollicis brevis (APB) and abductor digiti minimi (ADM) were obtained to measure muscle cross-sectional area (CSA), thickness, and echo intensity (EI). EI was determined using computer-assisted, grayscale analysis. Inter-rater and intra-rater reliability for quantitative muscle US in control subjects, and differences in muscle thickness, CSA, and EI between the CTS patient and control groups were analyzed. Relationships between quantitative US parameters and electrodiagnostic study results were evaluated. Quantitative muscle US had high inter-rater and intra-rater reliability in the control group. Muscle thickness and CSA were significantly decreased, and EI was significantly increased in the APB of the CTS group (all p<0.05). EI demonstrated a significant positive correlation with latency of the median motor and sensory NCS in CTS patients (p<0.05). These findings suggest that quantitative muscle US parameters may be useful for detecting muscle changes in CTS. Further study involving patients with other neuromuscular diseases is needed to evaluate peripheral muscle change using quantitative muscle US.
Evaluating Rapid Models for High-Throughput Exposure Forecasting (SOT)
High throughput exposure screening models can provide quantitative predictions for thousands of chemicals; however these predictions must be systematically evaluated for predictive ability. Without the capability to make quantitative, albeit uncertain, forecasts of exposure, the ...
Statistical shape analysis using 3D Poisson equation--A quantitatively validated approach.
Gao, Yi; Bouix, Sylvain
2016-05-01
Statistical shape analysis has been an important area of research with applications in biology, anatomy, neuroscience, agriculture, paleontology, etc. Unfortunately, the proposed methods are rarely quantitatively evaluated, and as shown in recent studies, when they are evaluated, significant discrepancies exist in their outputs. In this work, we concentrate on the problem of finding the consistent location of deformation between two population of shapes. We propose a new shape analysis algorithm along with a framework to perform a quantitative evaluation of its performance. Specifically, the algorithm constructs a Signed Poisson Map (SPoM) by solving two Poisson equations on the volumetric shapes of arbitrary topology, and statistical analysis is then carried out on the SPoMs. The method is quantitatively evaluated on synthetic shapes and applied on real shape data sets in brain structures. Copyright © 2016 Elsevier B.V. All rights reserved.
Quantitative method of medication system interface evaluation.
Pingenot, Alleene Anne; Shanteau, James; Pingenot, James D F
2007-01-01
The objective of this study was to develop a quantitative method of evaluating the user interface for medication system software. A detailed task analysis provided a description of user goals and essential activity. A structural fault analysis was used to develop a detailed description of the system interface. Nurses experienced with use of the system under evaluation provided estimates of failure rates for each point in this simplified fault tree. Means of estimated failure rates provided quantitative data for fault analysis. Authors note that, although failures of steps in the program were frequent, participants reported numerous methods of working around these failures so that overall system failure was rare. However, frequent process failure can affect the time required for processing medications, making a system inefficient. This method of interface analysis, called Software Efficiency Evaluation and Fault Identification Method, provides quantitative information with which prototypes can be compared and problems within an interface identified.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-17
... Evaluation and Research (CBER) and suggestions for further development. The public workshop will include... Evaluation and Research (HFM-210), Food and Drug Administration, 1401 Rockville Pike, suite 200N, Rockville... models to generate quantitative estimates of the benefits and risks of influenza vaccination. The public...
Pateman, B; Jinks, A M
1999-01-01
The focus of this paper is a study designed to explore the validity of quantitative approaches of student evaluation in a pre-registration degree programme. As managers of the students' education we were concerned that the quantitative method, which used lecturer criteria, may not fully represent students' views. The approach taken is that of a process-type strategy for curriculum evaluation as described by Parlett and Hamilton (1972). The aim of the study is to produce illuminative data, or students' 'stories' of their educational experiences through use of semi-structured interviews. The results are then compared to the current quantitative measurement tools designed to obtain 'snapshots' of the educational effectiveness of the curriculum. The quantitative measurement tools use Likert scale measurements of teacher-devised criterion statements. The results of the study give a rich source of qualitative data which can be used to inform future curriculum development. However, complete validation of the current quantitative instruments used was not achieved in this study. Student and teacher agendas in respect of important issues pertaining to the course programme were found to differ. Limitations of the study are given. There is discussion of the options open to the management team with regard to future development of curriculum evaluation systems.
Jungmann, Pia M.; Baum, Thomas; Bauer, Jan S.; Karampinos, Dimitrios C.; Link, Thomas M.; Li, Xiaojuan; Trattnig, Siegfried; Rummeny, Ernst J.; Woertler, Klaus; Welsch, Goetz H.
2014-01-01
Background. New quantitative magnetic resonance imaging (MRI) techniques are increasingly applied as outcome measures after cartilage repair. Objective. To review the current literature on the use of quantitative MRI biomarkers for evaluation of cartilage repair at the knee and ankle. Methods. Using PubMed literature research, studies on biochemical, quantitative MR imaging of cartilage repair were identified and reviewed. Results. Quantitative MR biomarkers detect early degeneration of articular cartilage, mainly represented by an increasing water content, collagen disruption, and proteoglycan loss. Recently, feasibility of biochemical MR imaging of cartilage repair tissue and surrounding cartilage was demonstrated. Ultrastructural properties of the tissue after different repair procedures resulted in differences in imaging characteristics. T2 mapping, T1rho mapping, delayed gadolinium-enhanced MRI of cartilage (dGEMRIC), and diffusion weighted imaging (DWI) are applicable on most clinical 1.5 T and 3 T MR scanners. Currently, a standard of reference is difficult to define and knowledge is limited concerning correlation of clinical and MR findings. The lack of histological correlations complicates the identification of the exact tissue composition. Conclusions. A multimodal approach combining several quantitative MRI techniques in addition to morphological and clinical evaluation might be promising. Further investigations are required to demonstrate the potential for outcome evaluation after cartilage repair. PMID:24877139
Comparison of Collection Methods for Fecal Samples in Microbiome Studies
Vogtmann, Emily; Chen, Jun; Amir, Amnon; Shi, Jianxin; Abnet, Christian C.; Nelson, Heidi; Knight, Rob; Chia, Nicholas; Sinha, Rashmi
2017-01-01
Prospective cohort studies are needed to assess the relationship between the fecal microbiome and human health and disease. To evaluate fecal collection methods, we determined technical reproducibility, stability at ambient temperature, and accuracy of 5 fecal collection methods (no additive, 95% ethanol, RNAlater Stabilization Solution, fecal occult blood test cards, and fecal immunochemical test tubes). Fifty-two healthy volunteers provided fecal samples at the Mayo Clinic in Rochester, Minnesota, in 2014. One set from each sample collection method was frozen immediately, and a second set was incubated at room temperature for 96 hours and then frozen. Intraclass correlation coefficients (ICCs) were calculated for the relative abundance of 3 phyla, 2 alpha diversity metrics, and 4 beta diversity metrics. Technical reproducibility was high, with ICCs for duplicate fecal samples between 0.64 and 1.00. Stability for most methods was generally high, although the ICCs were below 0.60 for 95% ethanol in metrics that were more sensitive to relative abundance. When compared with fecal samples that were frozen immediately, the ICCs were below 0.60 for the metrics that were sensitive to relative abundance; however, the remaining 2 alpha diversity and 3 beta diversity metrics were all relatively accurate, with ICCs above 0.60. In conclusion, all fecal sample collection methods appear relatively reproducible, stable, and accurate. Future studies could use these collection methods for microbiome analyses. PMID:27986704
Rybickova, Ivana; Vesela, Viera; Fales, Ivan; Skalicka, Pavlina; Jirsova, Katerina
2016-06-01
To assess the impact of autologous serum eye drops on the level of ocular surface apoptosis in patients with bilateral severe dry eye disease. This prospective study was conducted on 10 patients with severe dry eye due to graft versus host disease (group 1) and 6 patients with severe dry eye due to primary Sjögren's syndrome (group 2). Impression cytology specimens from the bulbar conjunctiva were obtained before and after a three-month treatment with 20% autologous serum eye drops applied a maximum of 12 times a day together with regular therapy with artificial tears. The percentage of apoptotic epithelial cells was evaluated immunochemically using anti-active caspase 3 antibody. In group 1, the mean percentage of apoptotic cells was 3.6% before the treatment. The three-month treatment led to a significant decrease to a mean percentage of 1.8% (P = 0.028). The mean percentage of apoptotic conjunctival cells decreased from 5.4% before the treatment to 3.8% in group 2; however, these results did not reach the level of significance. Three-month autologous serum treatment led to the improvement of ocular surface apoptosis, especially in the group of patients with severe dry eye due to graft versus host disease. This result supports the very positive effect of autologous serum on the ocular surface in patients suffering from severe dry eye.
NASA Astrophysics Data System (ADS)
Gajos, Katarzyna; Budkowski, Andrzej; Petrou, Panagiota; Pagkali, Varvara; Awsiuk, Kamil; Rysz, Jakub; Bernasik, Andrzej; Misiakos, Konstantinos; Raptis, Ioannis; Kakabakos, Sotirios
2018-06-01
Time-of-flight secondary ion mass spectrometry has been employed to examine, with biomolecular discrimination, sensing arm areas (20 μm × 600 μm) of integrated onto silicon chips Mach-Zehnder interferometers aiming to optimize their biofunctionalization with regard to indirect immunochemical (competitive) detection of ochratoxin A. Sensing areas are examined after: modification with (3-aminopropyl)triethoxysilane, spotting of OTA-ovalbumin conjugate (probe) from solutions with different concentration, blocking with bovine serum albumin, reaction with OTA-specific mouse monoclonal antibody followed by goat anti-mouse IgG secondary antibody. Component mass loadings of all proteins involved in immunodetection are determined from TOF-SIMS micro-analysis combined with ellipsometry of planar surfaces. These data show that partial desorption of surface-bound probe and blocking protein takes place upon primary immunoreaction to a degree that depends on probe concentration in spotting solution. Taking into account this desorption, apparent binding stoichiometry of both antibodies in immune complexes formed onto chip surface is determined more accurately than the respective evaluation based on real-time sensor response. In addition, mass loadings for probe and secondary antibody is observed to saturate for optimum probe concentrations. Also, principal component analysis of TOF-SIMS data could resolve both immunoreactions and biofunctionalization and discriminate surfaces prepared with optimum probe concentrations from those prepared using suboptimum ones.
Conjugation of hydroxyapatite nanocrystals with human immunoglobulin G for nanomedical applications.
Iafisco, Michele; Varoni, Elena; Di Foggia, Michele; Pietronave, Stefano; Fini, Milena; Roveri, Norberto; Rimondini, Lia; Prat, Maria
2012-02-01
Inorganic nanosized drug carriers are a promising field in nanomedicine applied to cancer. Their conjugation with antibodies combines the properties of the nanoparticles themselves with the specific and selective recognition ability of the antibodies to antigens. Biomimetic carbonate-hydroxyapatite (HA) nanoparticles were synthesized and fully characterized; human IgGs, used as model antibodies, were coupled to these nanocrystals. The maximum loading amount, the interaction modelling, the preferential orientation and the secondary structure modifications were evaluated using theoretical models (Langmuir, Freundlich and Langmuir-Freundlich) spectroscopic (UV-Vis, Raman), calorimetric (TGA), and immunochemical techniques (ELISA, Western Blot). HA nanoparticles of about 30 nm adsorbed human IgGs, in a dose-dependent, saturable and stable manner with micromolar affinity and adsorption capability around 2.3 mg/m(2). Adsorption isotherm could be described by Langmuir-Freundlich model, and was due to both energetically homogeneous and heterogeneous binding sites on HA surface, mainly of electrostatic nature. Binding did not induce secondary structure modification of IgGs. A preferential IgG end-on orientation with the involvement of IgG Fc moiety in the adsorption seems most probable due to the steric hindrance of their Fab domains. Biomimetic HA nanocrystals are suitable substrates to produce nanoparticles which can be functionalized with antibodies for efficient targeted drug delivery to tumours. Copyright © 2011 Elsevier B.V. All rights reserved.
Parra, Javier; Mercader, Josep V; Agulló, Consuelo; Abad-Somovilla, Antonio; Abad-Fuentes, Antonio
2012-02-17
Azoxystrobin is a modern strobilurin fungicide used around the world to combat prime diseases affecting highly valuable crops. Accordingly, residues of this chemical are frequently found in food, even though mostly under maximum tolerated levels. We herein describe the development of an indirect competitive immunoassay for the determination of azoxystrobin residues. A panel of monoclonal antibodies displaying subnanomolar affinity to azoxystrobin was generated using, as immunizing haptens in mice, four functionalized derivatives carrying the same spacer arm located at different rationally chosen positions. This collection of antibodies was thoroughly characterized with homologous and heterologous antigens, and the immunoassay consisting of monoclonal antibody AZo6#49 and the coating conjugate OVA-AZb6, which displayed an IC(50) value of 0.102 μg L(-1) and a LOD of 0.017 μg L(-1), was eventually optimized. The response to different pH and ionic strength conditions of the specific assay was studied using a biparametric approach. In addition, the influence of Tween 20 and organic solvents over the assay parameters was also evaluated. After optimization, the developed immunochemical assay was applied to the analysis of azoxystrobin in spiked juices of relevant fruits and vegetables, showing excellent recoveries between 2 and 500 μg L(-1). Copyright © 2011 Elsevier B.V. All rights reserved.
Xiao, Zhujun; Li, Bingsheng; Wang, Guozhen; Zhu, Weisi; Wang, Zhongqiu; Lin, Jinfeng; Xu, Angao; Wang, Xinying
2014-04-20
Methylation-sensitive high-resolution melting (MS-HRM) is a new technique for assaying DNA methylation, but its feasibility for assaying stool in patients with colorectal cancer (CRC) is unknown. First, the MS-HRM and methylation-specific PCR (MSP) detection limits were tested. Second, the methylation statuses of SFRP2 and VIM were analyzed in stool samples by MS-HRM, and in matching tumor and normal colon tissues via bisulfite sequencing PCR (BSP). Third, a case-control study evaluated the diagnostic sensitivity and specificity of MS-HRM relative to results obtained with MSP and the fecal immunochemical test (FIT). Finally, the linearity and reproducibility of MS-HRM were assessed. The detection limits of MS-HRM and MSP were 1% and 5%, respectively. The diagnostic sensitivities of MS-HRM (87.3%, 55/63) in stool and BSP in matching tumor tissue (92.1%, 58/63) were highly consistent (κ=0.744). The MS-HRM assay detected 92.5% (37/40) methylation in CRCs, 94.4% (34/36) in advanced adenomas, and 8.8% (5/57) in normal controls. The results of MS-HRM analysis were stable and reliable and showed fairly good linearity for both SFRP2 (P<0.001, R(2)=0.957) and VIM (P<0.001, R(2)=0.954). MS-HRM shows potential for CRC screening. Copyright © 2014 Elsevier B.V. All rights reserved.
A Systematic Quantitative-Qualitative Model: How To Evaluate Professional Services
ERIC Educational Resources Information Center
Yoda, Koji
1973-01-01
The proposed evaluation model provides for the assignment of relative weights to each criterion, and establishes a weighting system for calculating a quantitative-qualitative raw score for each service activity of a faculty member being reviewed. (Author)
Zhang, Yin; Wang, Lei
2013-01-01
Abstract The Clinical and Translational Science Awards (CTSA) program is one of the most important initiatives in translational medical funding. The quantitative evaluation of the efficiency and performance of the CTSA program has a significant referential meaning for the decision making of global translational medical funding. Using science mapping and scientometric analytic tools, this study quantitatively analyzed the scientific articles funded by the CTSA program. The results of the study showed that the quantitative productivities of the CTSA program had a stable increase since 2008. In addition, the emerging trends of the research funded by the CTSA program covered clinical and basic medical research fields. The academic benefits from the CTSA program were assisting its members to build a robust academic home for the Clinical and Translational Science and to attract other financial support. This study provided a quantitative evaluation of the CTSA program based on science mapping and scientometric analysis. Further research is required to compare and optimize other quantitative methods and to integrate various research results. PMID:24330689
Zhang, Yin; Wang, Lei; Diao, Tianxi
2013-12-01
The Clinical and Translational Science Awards (CTSA) program is one of the most important initiatives in translational medical funding. The quantitative evaluation of the efficiency and performance of the CTSA program has a significant referential meaning for the decision making of global translational medical funding. Using science mapping and scientometric analytic tools, this study quantitatively analyzed the scientific articles funded by the CTSA program. The results of the study showed that the quantitative productivities of the CTSA program had a stable increase since 2008. In addition, the emerging trends of the research funded by the CTSA program covered clinical and basic medical research fields. The academic benefits from the CTSA program were assisting its members to build a robust academic home for the Clinical and Translational Science and to attract other financial support. This study provided a quantitative evaluation of the CTSA program based on science mapping and scientometric analysis. Further research is required to compare and optimize other quantitative methods and to integrate various research results. © 2013 Wiley Periodicals, Inc.
Methods of albumin estimation in clinical biochemistry: Past, present, and future.
Kumar, Deepak; Banerjee, Dibyajyoti
2017-06-01
Estimation of serum and urinary albumin is routinely performed in clinical biochemistry laboratories. In the past, precipitation-based methods were popular for estimation of human serum albumin (HSA). Currently, dye-binding or immunochemical methods are widely practiced. Each of these methods has its limitations. Research endeavors to overcome such limitations are on-going. The current trends in methodological aspects of albumin estimation guiding the field have not been reviewed. Therefore, it is the need of the hour to review several aspects of albumin estimation. The present review focuses on the modern trends of research from a conceptual point of view and gives an overview of recent developments to offer the readers a comprehensive understanding of the subject. Copyright © 2017 Elsevier B.V. All rights reserved.
Autonomic innervation of the fish gut.
Olsson, Catharina
2009-01-01
The enteric nervous system follows a similar overall arrangement in all vertebrate groups. In fish, the majority of nerve cell bodies are found in the myenteric plexus, innervating muscles, blood vessels and glands. In this review, I describe similarities and differences in size, shape and transmitter content in enteric neurons in different fish species and also in comparison with other vertebrates, foremost mammals. The use of different histological and immunochemical methods is reviewed in a historical perspective including advantages and disadvantages of different methods. Lately, zebrafish have become an important model species for developmental studies of the nervous system, including the enteric nervous system, and this is briefly discussed. Finally, examples of how the enteric nervous system controls gut activity in fish is presented, focussing on the effect on gastrointestinal motility.
Fujita, H; Sassa, S; Toback, A C; Kappas, A
1987-01-01
Hepatoerythropoietic porphyria (HEP) is due to a marked deficiency of uroporphyrinogen (URO) decarboxylase, a cytosolic enzyme in the heme biosynthetic pathway. Using a radioimmunoassay method, we determined the concentration of URO decarboxylase protein in erythrocytes from a patient with mild HEP and found that the enzyme protein concentration had markedly decreased to less than 7% of the normal controls. This finding, however, was in contrast to the enzyme activity in the patient's erythrocytes, which was 16% of normal control levels and different from previously reported HEP cases in that erythrocytes in our patient contained disproportionately elevated URO decarboxylase activity in comparison to its immunoreactive material. Our findings suggests the possibility of a mutant isozyme in this patient that is not immunoreactive with an antibody raised against the normal enzyme. PMID:3571497
Immunochemical characterization of the "native" type III polysaccharide of group B Streptococcus
1976-01-01
The type III polysaccharide of -roup B Streptococcus has been isolated and purified by a method that employs washing of intact cells at neutral pH. That the polysaccharide prepared by this procedure is the "native" type III antigen is suggested by its molecular size in excess of 10(6) daltons, its degradation by acid and heat treatment to a fragment with immunologic characteristics of the classical HCl antigen, and its type-specific serologic activity. The type III polysaccharide in native form contains sialic acid, galactose, glucose, glucosamine, heptose, and mannose. It is acidic in nature, is resistant to neuramindiase degradation, contains no O-acetyl groups, and does not share antigenic determinants with capsular type K1 antigen of Escherichia coli or Group B polysaccharide antigen of Neiserria meningitidis. PMID:55450
Cross-reactions of Streptococcus mutans due to cell wall teichoic acid.
Chorpenning, F W; Cooper, H R; Rosen, S
1975-01-01
Antisera to the whole cells of Streptococcus mutans cross-reacted with antigen extracts from four other gram-positive species, as well as with those of three other oral streptococci. Similarly, antisera to these bacteria cross-reacted with extracts from S. mutans and with those from each other. Using a purified phenol extract of the walls of S. mutans, which was identified by chemical, immunochemical, and enzymatic analyses as glycerol teichoic acid, the cross-reactions were shown to be specific for a determinant of the teichoic acid backbone. Results were confirmed in immunodiffusion tests where clear bands of identify were shown. These observations point out the need for caution in sereological research empolying extracts of gram-positive bacteria and may be of interest in investigations of periodontal disease. Images PMID:809357
Ontogeny of a novel pituitary protein (7B2) in the human fetal intestine.
Suzuki, H; Christofides, N D; Adrian, T E; Chretien, M; Seidah, N G; Polak, J M; Bloom, S R
1985-11-28
The developmental profile of the concentration of a novel pituitary protein (7B2) was studied immunochemically in the human gastrointestinal tract from 12 weeks of gestation to 4 months after birth and was compared to the distribution in the adult. 7B2-like immunoreactivity (IR-7B2) was detected in all segments studied, but no gross changes were seen through fetal life. At term higher concentrations of IR-7B2 were found in the duodenum and the antrum, which is similar to the distribution of adult man. Gel permeation chromatography revealed that the main peak of 7B2 immunoreactivity in the fetal intestinal extract eluted with a Kav of 0.3. Similar elution profiles were also observed in extracts of human adult intestine.
Yamada, H; Ikeda-Wada, S; Oguri, K
1998-07-01
A new screening method for amphetamines was developed. It consists of derivatization with dansyl chloride, extraction of the derivative using a Sep-Pak C18 or a Bond Elut C18, solid phase extraction columns, and visualization of the fluorescence of the cartridge. A control test using drug-free urine showed no fluorescence. Amphetamine, methamphetamine and the methylenedioxy derivatives exhibited strong fluorescence, while related compounds, such as N-ethylamphetamine and fenetylline, were negative or weakly positive. The disadvantage of the present method is that it is a multi-step procedure and 20-30 min is required for screening. However, since it has a different specificity from the widely used immunochemical technique, it is suggested to be a useful screen for amphetamines.
USDA-ARS?s Scientific Manuscript database
Histidine (His)-tag is widely used for affinity purification of recombinant proteins, but the yield and purity of expressed proteins are quite different. Little information is available about quantitative evaluation of this procedure. The objective of the current study was to evaluate the His-tag pr...
Quantitative phase-contrast digital holographic microscopy for cell dynamic evaluation
NASA Astrophysics Data System (ADS)
Yu, Lingfeng; Mohanty, Samarendra; Berns, Michael W.; Chen, Zhongping
2009-02-01
The laser microbeam uses lasers to alter and/or to ablate intracellular organelles and cellular and tissue samples, and, today, has become an important tool for cell biologists to study the molecular mechanism of complex biological systems by removing individual cells or sub-cellular organelles. However, absolute quantitation of the localized alteration/damage to transparent phase objects, such as the cell membrane or chromosomes, was not possible using conventional phase-contrast or differential interference contrast microscopy. We report the development of phase-contrast digital holographic microscopy for quantitative evaluation of cell dynamic changes in real time during laser microsurgery. Quantitative phase images are recorded during the process of laser microsurgery and thus, the dynamic change in phase can be continuously evaluated. Out-of-focus organelles are re-focused by numerical reconstruction algorithms.
Wu, Cheng-Ching; Lin, Hung-Yu; Wang, Chao-Ping; Lu, Li-Fen; Yu, Teng-Hung; Hung, Wei-Chin; Houng, Jer-Yiing; Chung, Fu-Mei; Lee, Yau-Jiunn; Hu, Jin-Jia
2015-11-03
Prostate cancer remains the most common cancer in men. Qualitative or semi-quantitative immunochromatographic measurements of prostate specific antigen (PSA) have been shown to be simple, noninvasive and feasible. The aim of this study was to evaluate an optimized gold immunochromatographic strip device for the detection of PSA, in which the results can be analysed using a Chromogenic Rapid Test Reader to quantitatively assess the test results. This reader measures the reflectance of the signal line via a charge-coupled device camera. For quantitative analysis, PSA concentration was computed via a calibration equation. Capillary blood samples from 305 men were evaluated, and two independent observers interpreted the test results after 12 min. Blood samples were also collected and tested with a conventional quantitative assay. Sensitivity, specificity, positive and negative predictive values, and accuracy of the PSA rapid quantitative test system were 100, 96.6, 89.5, 100, and 97.4 %, respectively. Reproducibility of the test was 99.2, and interobserver variation was 8 % with a false positive rate of 3.4 %. The correlation coefficient between the ordinary quantitative assay and the rapid quantitative test was 0.960. The PSA rapid quantitative test system provided results quickly and was easy to use, so that tests using this system can be easily performed at outpatient clinics or elsewhere. This system may also be useful for initial cancer screening and for point-of-care testing, because results can be obtained within 12 min and at a cost lower than that of conventional quantitative assays.
A new method to evaluate image quality of CBCT images quantitatively without observers
Shimizu, Mayumi; Okamura, Kazutoshi; Yoshida, Shoko; Weerawanich, Warangkana; Tokumori, Kenji; Jasa, Gainer R; Yoshiura, Kazunori
2017-01-01
Objectives: To develop an observer-free method for quantitatively evaluating the image quality of CBCT images by applying just-noticeable difference (JND). Methods: We used two test objects: (1) a Teflon (polytetrafluoroethylene) plate phantom attached to a dry human mandible; and (2) a block phantom consisting of a Teflon step phantom and an aluminium step phantom. These phantoms had holes with different depths. They were immersed in water and scanned with a CB MercuRay (Hitachi Medical Corporation, Tokyo, Japan) at tube voltages of 120 kV, 100 kV, 80 kV and 60 kV. Superimposed images of the phantoms with holes were used for evaluation. The number of detectable holes was used as an index of image quality. In detecting holes quantitatively, the threshold grey value (ΔG), which differentiated holes from the background, was calculated using a specific threshold (the JND), and we extracted the holes with grey values above ΔG. The indices obtained by this quantitative method (the extracted hole values) were compared with the observer evaluations (the observed hole values). In addition, the contrast-to-noise ratio (CNR) of the shallowest detectable holes and the deepest undetectable holes were measured to evaluate the contribution of CNR to detectability. Results: The results of this evaluation method corresponded almost exactly with the evaluations made by observers. The extracted hole values reflected the influence of different tube voltages. All extracted holes had an area with a CNR of ≥1.5. Conclusions: This quantitative method of evaluating CBCT image quality may be more useful and less time-consuming than evaluation by observation. PMID:28045343
Wang, Li-Li; Zhang, Yun-Bin; Sun, Xiao-Ya; Chen, Sui-Qing
2016-05-08
Establish a quantitative analysis of multi-components by the single marker (QAMS) method for quality evaluation and validate its feasibilities by the simultaneous quantitative assay of four main components in Linderae Reflexae Radix. Four main components of pinostrobin, pinosylvin, pinocembrin, and 3,5-dihydroxy-2-(1- p -mentheneyl)- trans -stilbene were selected as analytes to evaluate the quality by RP-HPLC coupled with a UV-detector. The method was evaluated by a comparison of the quantitative results between the external standard method and QAMS with a different HPLC system. The results showed that no significant differences were found in the quantitative results of the four contents of Linderae Reflexae Radix determined by the external standard method and QAMS (RSD <3%). The contents of four analytes (pinosylvin, pinocembrin, pinostrobin, and Reflexanbene I) in Linderae Reflexae Radix were determined by the single marker of pinosylvin. This fingerprint was the spectra determined by Shimadzu LC-20AT and Waters e2695 HPLC that were equipped with three different columns.
Endo, Hiroki; Kato, Takayuki; Sakai, Eiji; Taniguchi, Leo; Arimoto, Jun; Kawamura, Harunobu; Higurashi, Takuma; Ohkubo, Hidenori; Nonaka, Takashi; Taguri, Masataka; Inamori, Masahiko; Yamanaka, Takeharu; Sakaguchi, Takashi; Hata, Yasuo; Nagase, Hajime; Nakajima, Atsushi
2017-02-01
Aspirin use is reportedly not to be associated with fecal immunochemical occult blood test (FIT) false-positive results for the detection of colorectal cancer. The need for additional small bowel exploration in FIT-positive, low-dose aspirin users with a negative colonoscopy is controversial. The aim of this study was to assess the ability of FIT to judge whether capsule endoscopy (CE) should be performed in low-dose aspirin users with negative colonoscopy and esophagogastroduodenoscopy findings by comparing FIT results with CE findings. A total of 264 consecutive low-dose aspirin users with negative colonoscopy and esophagogastroduodenoscopy who were scheduled to undergo CE at five hospitals in Japan were enrolled. Patients had been offered FIT prior to the CE. The association between the FIT results and the CE findings was then assessed. One hundred and fifty-seven patients were included in the final analysis. Eighty-four patients (53.5 %) had positive FIT results. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of positive FIT results for small bowel ulcers were 0.56, 0.47, 0.30, and 0.73, respectively. Furthermore, the NPV of positive FIT results for severe small bowel injury (Lewis score ≥790) was markedly high (0.90). When the analysis was performed only in low-dose aspirin users with anemia, the sensitivity of the positive FIT results was notably improved (0.72). Small bowel evaluation using CE is not recommended for FIT-negative, low-dose aspirin users. However, small bowel evaluation using CE should be considered in both FIT-positive and anemic low-dose aspirin users.
Cheng, Li; Qiao, Zhenguo; Xu, Chunfang; Shen, Jiaqing
2017-06-01
Midkine (MK) is involved in the pathogenesis of numerous malignancies, but the expression and effect of MK in acute pancreatitis (AP) have not been well studied and documented. In this study, the expression of MK was assayed in mice with L-arginine-induced AP. A recombinant human MK (rhMK) was introduced in this study to test the effect of MK on the L-arginine-induced AP. Serum amylase and lipase were assayed. Pancreas tissue samples were also collected for the evaluation of histological injury. Western blot and immunochemical staining of α-amylase and proliferating cell nuclear antigen were applied for the study of acinar regeneration in the pancreas. The elevation of MK expression was found in mice with AP induced by L-arginine. After rhMK administration, rhMK did not affect the severity of acute pancreatic injury in acute phase in L-arginine-induced pancreatitis in mice, in accordance with changes of serum amylase and lipase and the histological evaluation. But during the recovery phase, the area of remaining acinar cells was increased and the fibrosis was reduced in rhMK-treated mice. Furthermore, the expression of proliferating cell nuclear antigen and α-amylase was also upregulated after rhMK treatment. Midkine is over-expressed during AP in the animal model. Recombinant MK could promote the recovery of L-arginine-induced pancreatitis in mice. Therefore, MK may be involved in the regeneration of acinar cells in AP, and rhMK may be a possible therapeutic intervention for the repairment of AP. © 2016 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.
Michel, Y; McIntyre, M; Ginglinger, H; Ollert, M; Cifuentes, L; Blank, S; Spillner, E
2012-01-01
Immunoglobulin (Ig) E-mediated reactions to honeybee venom can cause severe anaphylaxis, sometimes with fatal consequences. Detailed knowledge of the allergic potential of all venom components is necessary to ensure proper diagnosis and treatment of allergy and to gain a better understanding of the allergological mechanisms of insect venoms. Our objective was to undertake an immunochemical and structural evaluation of the putative low-molecular-weight serine protease inhibitor Api m 6, a component of honeybee venom. We recombinantly produced Api m 6 as a soluble protein in Escherichia coli and in Spodoptera frugiperda (Sf9) insect cells.We also assessed specific IgE reactivity of venom-sensitized patients with 2 prokaryotically produced Api m 6 variants using enzyme-linked immunosorbent assay. Moreover, we built a structural model ofApi m 6 and compared it with other protease inhibitor structures to gain insights into the function of Api m 6. In a population of 31 honeybee venom-allergic patients, 26% showed specific IgE reactivity with prokaryotically produced Api m 6, showing it to be a minor but relevant allergen. Molecular modeling of Api m 6 revealed a typical fold of canonical protease inhibitors, supporting the putative function of this venom allergen. Although Api m 6 has a highly variant surface charge, its epitope distribution appears to be similar to that of related proteins. Api m 6 is a honeybee venom component with IgE-sensitizing potential in a fraction of venom-allergic patients. Recombinant Api m 6 can help elucidate individual component-resolved reactivity profiles and increase our understanding of immune responses to low-molecular-weight allergens
Tschmelak, Jens; Proll, Guenther; Riedt, Johannes; Kaiser, Joachim; Kraemmer, Peter; Bárzaga, Luis; Wilkinson, James S; Hua, Ping; Hole, J Patrick; Nudd, Richard; Jackson, Michael; Abuknesha, Ram; Barceló, Damià; Rodriguez-Mozaz, Sara; de Alda, Maria J López; Sacher, Frank; Stien, Jan; Slobodník, Jaroslav; Oswald, Peter; Kozmenko, Helena; Korenková, Eva; Tóthová, Lívia; Krascsenits, Zoltan; Gauglitz, Guenter
2005-02-15
A novel analytical system AWACSS (automated water analyser computer-supported system) based on immunochemical technology has been developed that can measure several organic pollutants at low nanogram per litre level in a single few-minutes analysis without any prior sample pre-concentration nor pre-treatment steps. Having in mind actual needs of water-sector managers related to the implementation of the Drinking Water Directive (DWD) (98/83/EC, 1998) and Water Framework Directive WFD (2000/60/EC, 2000), drinking, ground, surface, and waste waters were major media used for the evaluation of the system performance. The instrument was equipped with remote control and surveillance facilities. The system's software allows for the internet-based networking between the measurement and control stations, global management, trend analysis, and early-warning applications. The experience of water laboratories has been utilised at the design of the instrument's hardware and software in order to make the system rugged and user-friendly. Several market surveys were conducted during the project to assess the applicability of the final system. A web-based AWACSS database was created for automated evaluation and storage of the obtained data in a format compatible with major databases of environmental organic pollutants in Europe. This first part article gives the reader an overview of the aims and scope of the AWACSS project as well as details about basic technology, immunoassays, software, and networking developed and utilised within the research project. The second part article reports on the system performance, first real sample measurements, and an international collaborative trial (inter-laboratory tests) to compare the biosensor with conventional anayltical methods.
Fosbøl, M; Reving, S; Petersen, E H; Rossing, P; Lajer, M; Zerahn, B
2017-01-01
To investigate whether inclusion of quantitative data on blood flow distribution compared with visual qualitative evaluation improve the reliability and diagnostic performance of 99 m Tc-hydroxymethylene diphosphate three-phase bone scintigraphy (TPBS) in patients suspected for charcot neuropathic osteoarthropathy (CNO) of the foot. A retrospective cohort study of TPBS performed on 148 patients with suspected acute CNO referred from a single specialized diabetes care centre. The quantitative blood flow distribution was calculated based on the method described by Deutsch et al. All scintigraphies were re-evaluated by independent, blinded observers twice with and without quantitative data on blood flow distribution at ankle and focus level, respectively. The diagnostic validity of TPBS was determined by subsequent review of clinical data and radiological examinations. A total of 90 patients (61%) had confirmed diagnosis of CNO. The sensitivity, specificity and accuracy of three-phase bone scintigraphy without/with quantitative data were 89%/88%, 58%/62% and 77%/78%, respectively. The intra-observer agreement improved significantly by adding quantitative data in the evaluation (Kappa value 0·79/0·94). The interobserver agreement was not significantly improved. Adding quantitative data on blood flow distribution in the interpretation of TBPS improves intra-observer variation, whereas no difference in interobserver variation was observed. The sensitivity of TPBS in the diagnosis of CNO is high, but holds limited specificity. Diagnostic performance does not improve using quantitative data in the evaluation. This may be due to the reference intervals applied in the study or the absence of a proper gold standard diagnostic procedure for comparison. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
Quantitative methods in assessment of neurologic function.
Potvin, A R; Tourtellotte, W W; Syndulko, K; Potvin, J
1981-01-01
Traditionally, neurologists have emphasized qualitative techniques for assessing results of clinical trials. However, in recent years qualitative evaluations have been increasingly augmented by quantitative tests for measuring neurologic functions pertaining to mental state, strength, steadiness, reactions, speed, coordination, sensation, fatigue, gait, station, and simulated activities of daily living. Quantitative tests have long been used by psychologists for evaluating asymptomatic function, assessing human information processing, and predicting proficiency in skilled tasks; however, their methodology has never been directly assessed for validity in a clinical environment. In this report, relevant contributions from the literature on asymptomatic human performance and that on clinical quantitative neurologic function are reviewed and assessed. While emphasis is focused on tests appropriate for evaluating clinical neurologic trials, evaluations of tests for reproducibility, reliability, validity, and examiner training procedures, and for effects of motivation, learning, handedness, age, and sex are also reported and interpreted. Examples of statistical strategies for data analysis, scoring systems, data reduction methods, and data display concepts are presented. Although investigative work still remains to be done, it appears that carefully selected and evaluated tests of sensory and motor function should be an essential factor for evaluating clinical trials in an objective manner.
The Use of Quantitative SPECT/CT Imaging to Assess Residual Limb Health
2016-10-01
AWARD NUMBER: W81XWH-15-1-0669 TITLE: The Use of Quantitative SPECT/CT Imaging to Assess Residual Limb Health PRINCIPAL INVESTIGATOR...3. DATES COVERED 30 Sep 2015 - 29 Sep 2016 4. TITLE AND SUBTITLE The Use of Quantitative SPECT/CT Imaging to Assess Residual Limb Health 5a...amputation and subsequently evaluate the utility of non-invasive imaging for evaluating the impact of next-generation socket technologies on the health of
Evaluating Research Administration: Methods and Utility
ERIC Educational Resources Information Center
Marina, Sarah; Davis-Hamilton, Zoya; Charmanski, Kara E.
2015-01-01
Three studies were jointly conducted by the Office of Research Administration and Office of Proposal Development at Tufts University to evaluate the services within each respective office. The studies featured assessments that used, respectively, (1) quantitative metrics; (2) a quantitative satisfaction survey with limited qualitative questions;…
High Resolution Qualitative and Quantitative MR Evaluation of the Glenoid Labrum
Iwasaki, Kenyu; Tafur, Monica; Chang, Eric Y.; SherondaStatum; Biswas, Reni; Tran, Betty; Bae, Won C.; Du, Jiang; Bydder, Graeme M.; Chung, Christine B.
2015-01-01
Objective To implement qualitative and quantitative MR sequences for the evaluation of labral pathology. Methods Six glenoid labra were dissected and the anterior and posterior portions were divided into normal, mildly degenerated, or severely degenerated groups using gross and MR findings. Qualitative evaluation was performed using T1-weighted, proton density-weighted (PD), spoiled gradient echo (SPGR) and ultra-short echo time (UTE) sequences. Quantitative evaluation included T2 and T1rho measurements as well as T1, T2*, and T1rho measurements acquired with UTE techniques. Results SPGR and UTE sequences best demonstrated labral fiber structure. Degenerated labra had a tendency towards decreased T1 values, increased T2/T2* values and increased T1 rho values. T2* values obtained with the UTE sequence allowed for delineation between normal, mildly degenerated and severely degenerated groups (p<0.001). Conclusion Quantitative T2* measurements acquired with the UTE technique are useful for distinguishing between normal, mildly degenerated and severely degenerated labra. PMID:26359581
Andersson, Maria; Stephanson, Nikolai; Ohman, Inger; Terzuoli, Tommy; Lindh, Jonatan D; Beck, Olof
2014-04-01
Opiates comprise a class of abused drugs that is of primary interest in clinical and forensic urine drug testing. Determination of heroin, codeine, or a multi-drug ingestion is complicated since both heroin and codeine can lead to urinary excretion of free and conjugated morphine. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) offers advantage over gas chromatography-mass spectrometry by simplifying sample preparation but increases the number of analytes. A method based on direct injection of five-fold diluted urine for confirmation of morphine, morphine-3-glucuronide, morphine-6-glucuronide, codeine, codeine-6-glucuronide and 6-acetylmorphine was validated using LC-MS/MS in positive electrospray mode monitoring two transitions using selected reaction monitoring. The method was applied for the analysis of 3155 unknown urine samples which were positive for opiates in immunochemical screening. A linear response was observed for all compounds in the calibration curves covering more than three orders of magnitude. Cut off was set to 2 ng/ml for 6-acetylmorphine and 150 ng/ml for the other analytes. 6-Acetylmorphine was found to be effective (sensitivity 82%) in detecting samples as heroin intake. Morphine-3-glucuronide and codeine-6-glucuronide was the predominant components of total morphine and codeine, 84% and 93%, respectively. The authors have validated a robust LC-MS/MS method for rapid qualitative and quantitative analysis of opiates in urine. 6-Acetylmorphine has been demonstrated as a sensitive and important parameter for a heroin intake. A possible interpretation strategy to conclude the source of detected analytes was proposed. The method might be further developed by reducing the number of analytes to morphine-3-glucuronide, codeine-6-glucuronide and 6-acetylmorphine without compromising test performance. Copyright © 2013 John Wiley & Sons, Ltd.
Zajicek, James L.; Tillitt, Donald E.; Huckins, James N.; Petty, Jimmie D.; Potts, Michael E.; Nardone, David A.
1996-01-01
Determination of PCBs in biological tissue extracts by enzyme-linked immunosorbent assays (ELISAs) can be problematic, since the hydrophobic solvents used for their extraction and isolation from interfering biochemicals have limited compatibility with the polar solvents (e.g. methanol/water) and the immunochemical reagents used in ELISA. Our studies of these solvent effects indicate that significant errors can occur when microliter volumes of PCB containing extracts, in hydrophobic solvents, are diluted directly into methanol/water diluents. Errors include low recovery and excess variability among sub-samples taken from the same sample dilution. These errors are associated with inhomogeneity of the dilution, which is readily visualized by the use of a hydrophobic dye, Solvent Blue 35. Solvent Blue 35 is also used to visualize the evaporative removal of hydrophobic solvent and the dissolution of the resulting PCB/dye residue by pure methanol and 50% (v/v) methanol/water, typical ELISA diluents. Evaporative removal of isooctane by an ambient temperature nitrogen purge with subsequent dissolution in 100% methanol gives near quantitative recovery of model PCB congeners. We also compare concentrations of total PCBs from ELISA (ePCB) to their corresponding concentrations determined from capillary gas chromatography (GC) in selected fish sample extracts and dialysates of semipermeable membrane device (SPMD) passive samplers using an optimized solvent exchange procedure. Based on Aroclor 1254 calibrations, ePCBs (ng/mL) determined in fish extracts are positively correlated with total PCB concentrations (ng/mL) determined by GC: ePCB = 1.16 * total-cPCB - 5.92. Measured ePCBs (ng/3 SPMDs) were also positively correlated (r2 = 0.999) with PCB totals (ng/3 SPMDs) measured by GC for dialysates of SPMDs: ePCB = 1.52 * total PCB - 212. Therefore, this ELISA system for PCBs can be a rapid alternative to traditional GC analyses for determination of PCBs in extracts of biota or in SPMD dialysates.
Nanci, A; Zalzal, S; Lavoie, P; Kunikata, M; Chen, W; Krebsbach, P H; Yamada, Y; Hammarström, L; Simmer, J P; Fincham, A G; Snead, M L; Smith, C E
1998-08-01
Mineralized tissues are unique in using proteins to attract and organize calcium and phosphate ions into a structured mineral phase. A precise knowledge of the expression and extracellular distribution of matrix proteins is therefore very important in understanding their function. The purpose of this investigation was to obtain comparative information on the expression, intracellular and extracellular distribution, and dynamics of proteins representative of the two main classes of enamel matrix proteins. Amelogenins were visualized using an antibody and an mRNA probe prepared against the major alternatively spliced isoform in rodents, and nonamelogenins by antibodies and mRNA probes specific to one enamel protein referred to by three names: ameloblastin, amelin, and sheathlin. Qualitative and quantitative immunocytochemistry, in combination with immunoblotting and in situ hybridization, indicated a correlation between mRNA signal and sites of protein secretion for amelogenin, but not for ameloblastin, during the early presecretory and mid- to late maturation stages, during which mRNA signals were detected but no proteins appeared to be secreted. Extracellular amelogenin immunoreactivity was generally weak near secretory surfaces, increasing over a distance of about 1.25 microm to reach a level slightly above an amount expected if the protein were being deposited evenly across the enamel layer. Immunolabeling for ameloblastin showed an inverse pattern, with relatively more gold particles near secretory surfaces and much fewer deeper into the enamel layer. Administration of brefeldin A and cycloheximide to stop protein secretion revealed that the immunoblotting pattern of amelogenin was relatively stable, whereas ameloblastin broke down rapidly into lower molecular weight fragments. The distance from the cell surface at which immunolabeling for amelogenin stabilized generally corresponded to the point at which that for ameloblastin started to show a net reduction. These data suggest a correlation between the distribution of amelogenin and ameloblastin and that intact ameloblastin has a transient role in promoting/stabilizing crystal elongation. (J Histochem Cytochem 46:911-934, 1998)
Kiseleva, Elena P; Mikhailopulo, Konstantin I; Zdorovenko, Evelina L; Knirel, Yuriy A; Novik, Galina I
2017-12-20
Role of microorganisms in induction of/protection from autoimmune diseases is proven though molecular mechanisms and bacterial/viral/yeast biopolymers responsible for these effects are in the research stage. Autoantobodies (AAbs) to thyroid peroxidase (anti-TPO) and thyroglobulin (anti-Tg) as well as AAbs to transglutaminase 2 (anti-TG2) and antibodies to gliadins (anti-gliadins) are serological markers of autoimmune thyroid disease and celiac disease, respectively, and players in pathogenesis of these autoimmune diseases. In current study, biopolymer of Bifidobacterium bifidum BIM В-733D that interacts selectively with anti-gliadins (Bb-G anti-gliadins ) was isolated by affinity chromatography with anti-gliadins, purified by size exclusion chromatography on TSK 40 gel and identified by NMR as linear α-(1 → 6)-d-glucan with molecular mass about 5000 Da. It was proven that compounds Bb-G anti-gliadins and Bb-G anti-TPO /Bb-G anti-Tg isolated early from the same strain [Kiseleva, E. P. et al., Benef Microbes.2013, 4, 375 -391] are the same substance designated G Bb . Its unique immunochemical property is the ability to interact selectively with anti-TPO, anti-Tg, anti-TG2 and anti-gliadins in presence of no less than 10-fold excess of total immunoglobulins of class G (tIgG), as it was proven by ELISA. Synthesis of G Bb -bovine serum albumin (G Bb -BSA) conjugate is an example of increasing the reliability and reproducibility of ELISA results by mediated immobilization of a polysaccharide covalently attached to a well-adsorbed protein. Taking into account that there are population of bispecific anti-gliadins (anti-gliadins and anti-TG2 simultaneously) we regard our data as first argument in favor of hypothesis that G Bb differentiates between human AAbs per se and other human Ig (e.g. antibodies to antigens of infectious agents) due to its binding with a yet unidentified site which is present in the molecules of all AAbs (independently on their specificity) and absent in other human Igs. Copyright © 2018 Elsevier Ltd. All rights reserved.
Davis, Stacy N; Christy, Shannon M; Chavarria, Enmanuel A; Abdulla, Rania; Sutton, Steven K; Schmidt, Alyssa R; Vadaparampil, Susan T; Quinn, Gwendolyn P; Simmons, Vani N; Ufondu, Chukwudi B; Ravindra, Chitra; Schultz, Ida; Roetzheim, Richard G; Shibata, David; Meade, Cathy D; Gwede, Clement K
2017-04-15
The objective of the current study was to improve colorectal cancer (CRC) screening uptake with the fecal immunochemical test (FIT). The current study investigated the differential impact of a multicomponent, targeted, low-literacy educational intervention compared with a standard, nontargeted educational intervention. Patients aged 50 to 75 years who were of average CRC risk and not up-to-date with CRC screening were recruited from either a federally qualified health center or a primary care community health clinic. Patients were randomized to the intervention condition (targeted photonovella booklet/DVD plus FIT kit) or comparison condition (standard Centers for Disease Control and Prevention brochure plus FIT kit). The main outcome was screening with FIT within 180 days of delivery of the intervention. Of the 416 participants, 54% were female; the participants were racially and ethnically diverse (66% white, 10% Hispanic, and 28% African American), predominantly of low income, and insured (the majority had county health insurance). Overall, the FIT completion rate was 81%, with 78.1% of participants in the intervention versus 83.5% of those in the comparison condition completing FIT (P = .17). In multivariate analysis, having health insurance was found to be the primary factor predicting a lack of FIT screening (adjusted odds ratio, 2.10; 95% confidence interval, 1.04-4.26 [P = .04]). The multicomponent, targeted, low-literacy materials were not found to be significantly different or more effective in increasing FIT uptake compared with the nontargeted materials. Provision of a FIT test plus education may provide a key impetus to improve the completion of CRC screening. The type of educational material (targeted vs nontargeted) may matter less. The findings of the current study provide a unique opportunity for clinics to adopt FIT and to choose the type of patient education materials based on clinic, provider, and patient preferences. Cancer 2017;123:1390-1400. © 2016 American Cancer Society. © 2016 American Cancer Society.
Guiriguet, Carolina; Pera, Guillem; Castells, Antoni; Toran, Pere; Grau, Jaume; Rivero, Irene; Buron, Andrea; Macià, Francesc; Vela-Vallespín, Carmen; Vilarrubí-Estrella, Mercedes; Marzo-Castillejo, Mercedes
2017-08-07
There is controversy regarding how comorbidity impacts on colorectal cancer screening, especially in the context of organised programmes. The aim of this study is to assess the effect of comorbidities on participation in the Barcelona population-based colorectal cancer screening programme (BCCSP). Cross-sectional study carried out in ten primary care centres involved in the BCCSP. Individuals aged 50 to 69, at average risk of colorectal cancer, who were invited to participate in the first round of the faecal immunochemical test-based BCCSP were included (2011-2012). The main variable was participation in the BCCSP. Comorbidity was assessed by clinical risk group status. Other adjusting variables were age, sex, socioeconomic deprivation, visits to primary care, smoking, alcohol consumption and body mass index. Logistic regression models were used to test the association between participation in the programme and potential explanatory variables. The results were given as incidence rate ratios (IRR) and their 95% confidence intervals (CI). Of the 36,208 individuals included, 17,404 (48%) participated in the BCCSP. Participation was statistically significantly higher in women, individuals aged 60 to 64, patients with intermediate socioeconomic deprivation, and patients with more medical visits. There was a higher rate of current smoking, high-risk alcohol intake, obesity and individuals in the highest comorbidity categories in the non-participation group. In the adjusted analysis, only individuals with multiple minor chronic diseases were more likely to participate in the BCCSP (IRR 1.14; 95% CI [1.06 to 1.22]; p < 0.001). In contrast, having three or more dominant chronic diseases was associated with lower participation in the screening programme (IRR 0.76; 95% CI [0.65 to 0.89]; p = 0.001). Having three or more dominant chronic diseases, was associated with lower participation in a faecal immunochemical test-based colorectal cancer screening programme, whereas individuals with multiple minor chronic diseases were more likely to participate. Further research is needed to explore comorbidity as a cause of non-participation in colorectal cancer screening programmes and which individuals could benefit most from colorectal cancer screening.
Halloran, Stephen
2017-01-01
Objectives Through the National Health Service (NHS) Bowel Cancer Screening Programme (BCSP), men and women in England aged between 60 and 74 years are invited for colorectal cancer (CRC) screening every 2 years using the guaiac faecal occult blood test (gFOBT). The aim of this analysis was to estimate the cost–utility of the faecal immunochemical test for haemoglobin (FIT) compared with gFOBT for a cohort beginning screening aged 60 years at a range of FIT positivity thresholds. Design We constructed a cohort-based Markov state transition model of CRC disease progression and screening. Screening uptake, detection, adverse event, mortality and cost data were taken from BCSP data and national sources, including a recent large pilot study of FIT screening in the BCSP. Results Our results suggest that FIT is cost-effective compared with gFOBT at all thresholds, resulting in cost savings and quality-adjusted life years (QALYs) gained over a lifetime time horizon. FIT was cost-saving (p<0.001) and resulted in QALY gains of 0.014 (95% CI 0.012 to 0.017) at the base case threshold of 180 µg Hb/g faeces. Greater health gains and cost savings were achieved as the FIT threshold was decreased due to savings in cancer management costs. However, at lower thresholds, FIT was also associated with more colonoscopies (increasing from 32 additional colonoscopies per 1000 people invited for screening for FIT 180 µg Hb/g faeces to 421 additional colonoscopies per 1000 people invited for screening for FIT 20 µg Hb/g faeces over a 40-year time horizon). Parameter uncertainty had limited impact on the conclusions. Conclusions This is the first published economic analysis of FIT screening in England using data directly comparing FIT with gFOBT in the NHS BSCP. These results for a cohort starting screening aged 60 years suggest that FIT is highly cost-effective at all thresholds considered. Further modelling is needed to estimate economic outcomes for screening across all age cohorts simultaneously. PMID:29079605
Jagannath, Badrinath; Muthukumar, Sriram; Prasad, Shalini
2018-08-03
We have investigated the role of kosmotropic anionic moieties and chaotropic cationic moieties of room temperature hydrophilic ionic liquids in enhancing the biosensing performance of affinity based immunochemical biosensors in human sweat. Two ionic liquids, 1-butyl-3-methylimidazolium tetrafluoroborate (BMIM[BF 4 ]) and choline dihydrogen phosphate (Choline[DHP]) were investigated in this study with Choline[DHP] being more kosmotropic in nature having a more protein stabilizing effect based on the hofmeister series. Non-faradaic interfacial charge transfer has been employed as the mechanism for evaluating the formation and the biosensing of capture probe antibodies in room temperature ionic liquids (RTILs)/aqueous human sweat interface. The charge of the ionic moieties were utilized to form compact electrical double layers around the antibodies for enhancing the stability of the antibody capture probes, which was evaluated through zeta potential measurements. The zeta potential measurements indicated stability of antibodies due to electrostatic repulsion of the RTIL charged moieties encompassing the antibodies, thus preventing any aggregation. Here, we report for the first time of non-faradaic electrochemical impedance spectroscopy equivalent circuit model analysis for analyzing and interpreting affinity based biosensing at hybrid electrode/ionic liquid-aqueous sweat buffer interface guided by the choice of the ionic liquid. Interleukin-6 (IL-6) and cortisol two commonly occurring biomarkers in human sweat were evaluated using this method. The limit of detection (LOD) obtained using both ionic liquids for IL-6 was 0.2 pg mL -1 with cross-reactivity studies indicating better performance of IL-6 detection using Choline[DHP] and no response to cross-reactive molecule. The LOD of 0.1 ng/mL was achieved for cortisol and the cross-reactivity studies indicated that cortisol antibody in BMIM[BF 4 ] did not show any signal response to cross-reactive molecules. Furthermore, improved sensitivity and LOD was achieved using ionic liquids as compared to capture probes in aqueous buffer. Copyright © 2018 Elsevier B.V. All rights reserved.
Applying Quantitative Approaches to the Formative Evaluation of Antismoking Campaign Messages
Parvanta, Sarah; Gibson, Laura; Forquer, Heather; Shapiro-Luft, Dina; Dean, Lorraine; Freres, Derek; Lerman, Caryn; Mallya, Giridhar; Moldovan-Johnson, Mihaela; Tan, Andy; Cappella, Joseph; Hornik, Robert
2014-01-01
This article shares an in-depth summary of a formative evaluation that used quantitative data to inform the development and selection of promotional ads for the antismoking communication component of a social marketing campaign. A foundational survey provided cross-sectional data to identify beliefs about quitting smoking that campaign messages should target, as well as beliefs to avoid. Pretesting draft ads against quantitative indicators of message effectiveness further facilitated the selection and rejection of final campaign ads. Finally, we consider lessons learned from the process of balancing quantitative methods and judgment to make formative decisions about more and less promising persuasive messages for campaigns. PMID:24817829
Liu, Kehui; Zhang, Jiyang; Fu, Bin; Xie, Hongwei; Wang, Yingchun; Qian, Xiaohong
2014-07-01
Precise protein quantification is essential in comparative proteomics. Currently, quantification bias is inevitable when using proteotypic peptide-based quantitative proteomics strategy for the differences in peptides measurability. To improve quantification accuracy, we proposed an "empirical rule for linearly correlated peptide selection (ERLPS)" in quantitative proteomics in our previous work. However, a systematic evaluation on general application of ERLPS in quantitative proteomics under diverse experimental conditions needs to be conducted. In this study, the practice workflow of ERLPS was explicitly illustrated; different experimental variables, such as, different MS systems, sample complexities, sample preparations, elution gradients, matrix effects, loading amounts, and other factors were comprehensively investigated to evaluate the applicability, reproducibility, and transferability of ERPLS. The results demonstrated that ERLPS was highly reproducible and transferable within appropriate loading amounts and linearly correlated response peptides should be selected for each specific experiment. ERLPS was used to proteome samples from yeast to mouse and human, and in quantitative methods from label-free to O18/O16-labeled and SILAC analysis, and enabled accurate measurements for all proteotypic peptide-based quantitative proteomics over a large dynamic range. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Jha, Abhinav K; Song, Na; Caffo, Brian; Frey, Eric C
2015-04-13
Quantitative single-photon emission computed tomography (SPECT) imaging is emerging as an important tool in clinical studies and biomedical research. There is thus a need for optimization and evaluation of systems and algorithms that are being developed for quantitative SPECT imaging. An appropriate objective method to evaluate these systems is by comparing their performance in the end task that is required in quantitative SPECT imaging, such as estimating the mean activity concentration in a volume of interest (VOI) in a patient image. This objective evaluation can be performed if the true value of the estimated parameter is known, i.e. we have a gold standard. However, very rarely is this gold standard known in human studies. Thus, no-gold-standard techniques to optimize and evaluate systems and algorithms in the absence of gold standard are required. In this work, we developed a no-gold-standard technique to objectively evaluate reconstruction methods used in quantitative SPECT when the parameter to be estimated is the mean activity concentration in a VOI. We studied the performance of the technique with realistic simulated image data generated from an object database consisting of five phantom anatomies with all possible combinations of five sets of organ uptakes, where each anatomy consisted of eight different organ VOIs. Results indicate that the method provided accurate ranking of the reconstruction methods. We also demonstrated the application of consistency checks to test the no-gold-standard output.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ohnishi, Masato, E-mail: masato.ohnishi@rift.mech.tohoku.ac.jp; Suzuki, Ken; Miura, Hideo, E-mail: hmiura@rift.mech.tohoku.ac.jp
2015-04-15
When a radial strain is applied to a carbon nanotube (CNT), the increase in local curvature induces orbital hybridization. The effect of the curvature-induced orbital hybridization on the electronic properties of CNTs, however, has not been evaluated quantitatively. In this study, the strength of orbital hybridization in CNTs under homogeneous radial strain was evaluated quantitatively. Our analyses revealed the detailed procedure of the change in electronic structure of CNTs. In addition, the dihedral angle, the angle between π-orbital axis vectors of adjacent atoms, was found to effectively predict the strength of local orbital hybridization in deformed CNTs.
[Criteria of scientific validity in research].
Pelletier, Céline; Pagé, Ginette
2002-03-01
The purpose of this article is to present the evaluative criteria of qualitative and quantitative research. Philosophical foundations of positivism, postpositivism and constructivism are explored. Triangulation and crystallization expose the controversies about them. Finally, Lincoln and Guba criteria are retained for the evaluation of qualitative and quantitative research.
Pansharpening on the Narrow Vnir and SWIR Spectral Bands of SENTINEL-2
NASA Astrophysics Data System (ADS)
Vaiopoulos, A. D.; Karantzalos, K.
2016-06-01
In this paper results from the evaluation of several state-of-the-art pansharpening techniques are presented for the VNIR and SWIR bands of Sentinel-2. A procedure for the pansharpening is also proposed which aims at respecting the closest spectral similarities between the higher and lower resolution bands. The evaluation included 21 different fusion algorithms and three evaluation frameworks based both on standard quantitative image similarity indexes and qualitative evaluation from remote sensing experts. The overall analysis of the evaluation results indicated that remote sensing experts disagreed with the outcomes and method ranking from the quantitative assessment. The employed image quality similarity indexes and quantitative evaluation framework based on both high and reduced resolution data from the literature didn't manage to highlight/evaluate mainly the spatial information that was injected to the lower resolution images. Regarding the SWIR bands none of the methods managed to deliver significantly better results than a standard bicubic interpolation on the original low resolution bands.
ERIC Educational Resources Information Center
Beck, Christopher W.
2018-01-01
Multiple national reports have pushed for the integration of quantitative concepts into the context of disciplinary science courses. The aim of this study was to evaluate the quantitative and statistical literacy of biology students and explore learning gains when those skills were taught implicitly in the context of biology. I examined gains in…
Are Teacher Course Evaluations Biased against Faculty That Teach Quantitative Methods Courses?
ERIC Educational Resources Information Center
Royal, Kenneth D.; Stockdale, Myrah R.
2015-01-01
The present study investigated graduate students' responses to teacher/course evaluations (TCE) to determine if students' responses were inherently biased against faculty who teach quantitative methods courses. Item response theory (IRT) and Differential Item Functioning (DIF) techniques were utilized for data analysis. Results indicate students…
A quantitative method for evaluating alternatives. [aid to decision making
NASA Technical Reports Server (NTRS)
Forthofer, M. J.
1981-01-01
When faced with choosing between alternatives, people tend to use a number of criteria (often subjective, rather than objective) to decide which is the best alternative for them given their unique situation. The subjectivity inherent in the decision-making process can be reduced by the definition and use of a quantitative method for evaluating alternatives. This type of method can help decision makers achieve degree of uniformity and completeness in the evaluation process, as well as an increased sensitivity to the factors involved. Additional side-effects are better documentation and visibility of the rationale behind the resulting decisions. General guidelines for defining a quantitative method are presented and a particular method (called 'hierarchical weighted average') is defined and applied to the evaluation of design alternatives for a hypothetical computer system capability.
Miyata, Hiroaki; Kai, Ichiro
2006-05-01
Debate about the relationship between quantitative and qualitative paradigms is often muddled and confused and the clutter of terms and arguments has resulted in the concepts becoming obscure and unrecognizable. It is therefore very important to reconsider evaluation criteria regarding rigor in social science. As Lincoln & Guba have already compared quantitative paradigms (validity, reliability, neutrality, generalizability) with qualitative paradigms (credibility, dependability, confirmability, transferability), we have discuss use of evaluation criteria based on pragmatic perspective. Validity/Credibility is the paradigm concerned to observational framework, while Reliability/Dependability refer to the range of stability in observations, Neutrality/Confirmability reflect influences between observers and subjects, Generalizability/Transferability have epistemological difference in the way findings are applied. Qualitative studies, however, does not always chose the qualitative paradigms. If we assume the stability to some extent, it is better to use the quantitative paradigm (reliability). Moreover as a quantitative study can not always guarantee a perfect observational framework, with stability in all phases of observations, it is useful to use qualitative paradigms to enhance the rigor in the study.
[Doppler echocardiography of tricuspid insufficiency. Methods of quantification].
Loubeyre, C; Tribouilloy, C; Adam, M C; Mirode, A; Trojette, F; Lesbre, J P
1994-01-01
Evaluation of tricuspid incompetence has benefitted considerably from the development of Doppler ultrasound. In addition to direct analysis of the valves, which provides information about the mechanism involved, this method is able to provide an accurate evaluation, mainly through use of the Doppler mode. In addition to new criteria being evaluated (mainly the convergence zone of the regurgitant jet), some indices are recognised as good quantitative parameters: extension of the regurgitant jet into the right atrium, anterograde tricuspid flow, laminar nature of the regurgitant flow, analysis of the flow in the supra-hepatic veins, this is only semi-quantitative, since the calculation of the regurgitation fraction from the pulsed Doppler does not seem to be reliable; This accurate semi-quantitative evaluation is made possible by careful and consistent use of all the criteria available. The authors set out to discuss the value of the various evaluation criteria mentioned in the literature and try to define a practical approach.
Wang, Kai; Liu, Menglong; Su, Zhongqing; Yuan, Shenfang; Fan, Zheng
2018-08-01
To characterize fatigue cracks, in the undersized stage in particular, preferably in a quantitative and precise manner, a two-dimensional (2D) analytical model is developed for interpreting the modulation mechanism of a "breathing" crack on guided ultrasonic waves (GUWs). In conjunction with a modal decomposition method and a variational principle-based algorithm, the model is capable of analytically depicting the propagating and evanescent waves induced owing to the interaction of probing GUWs with a "breathing" crack, and further extracting linear and nonlinear wave features (e.g., reflection, transmission, mode conversion and contact acoustic nonlinearity (CAN)). With the model, a quantitative correlation between CAN embodied in acquired GUWs and crack parameters (e.g., location and severity) is obtained, whereby a set of damage indices is proposed via which the severity of the crack can be evaluated quantitatively. The evaluation, in principle, does not entail a benchmarking process against baseline signals. As validation, the results obtained from the analytical model are compared with those from finite element simulation, showing good consistency. This has demonstrated accuracy of the developed analytical model in interpreting contact crack-induced CAN, and spotlighted its application to quantitative evaluation of fatigue damage. Copyright © 2018 Elsevier B.V. All rights reserved.
Hemangiopericytoma in the lateral ventricle.
Suzuki, Sakiko; Wanifuchi, Hiroshi; Shimizu, Takashi; Kubo, Osami
2009-11-01
A 31-year-old female presented with a particularly rare hemangiopericytoma (HPC) in the right lateral ventricle manifesting as a 6-month history of visual disturbance and headache. Left hemianopsia and choked disc were identified by an ophthalmologist who referred her to us. Magnetic resonance imaging demonstrated a 5-cm homogeneously enhanced mass in the trigone of the right lateral ventricle. The tumor was totally removed by two stage surgery. The histological findings were consistent with HPC. HPC is very important to differentiate from meningioma and solitary fibrous tumors because HPC is more aggressive. The histological and immunochemical findings are important for the differential diagnosis. The present case showed no local recurrence or metastasis without radiation therapy for 4 years, indicating that radiation therapy is not absolutely imperative for patients with intraventricular HPC showing low MIB-1 staining index after total removal.
Immunochemical detection of food-derived isothiocyanate as a lysine conjugate.
Nakamura, Toshiyuki; Kitamoto, Noritoshi; Osawa, Toshihiko; Kato, Yoji
2010-01-01
In a previous study we prepared monoclonal antibody against allyl isothiocyanate (AITC)-modified lysine (Lys), and found that AITC reacted with Lys under physiological conditions in vitro (T. Nakamura et al., Chem. Res. Toxicol., 22, 536-542 (2009)). In the present study, antibodies against benzyl isothiocyanate (ITC), 6-methylsulfinylhexyl ITC and phenethyl ITC modified protein were prepared, and the respective monoclonal antibodies, B6C9, 6MS3D10, and PE3A10 were obtained. These antibodies were applied to ITC detection in food using shredded Wasabia japonica (wasabi) and ground Carica papaya (papaya) seed by trapping ITC with biotin-labeled bovine serum albumin. ITC formation from the wasabi and papaya seed samples was confirmed using the antibodies in a dose-dependent manner. These antibodies might be applicable in identifying food-derived ITC.
Effect of light chain V region duplication on IgG oligomerization and in vivo efficacy.
Shuford, W; Raff, H V; Finley, J W; Esselstyn, J; Harris, L J
1991-05-03
A human immunoglobulin G1 (IgG1) antibody oligomer was isolated from a transfected myeloma cell line that produced a monoclonal antibody to group B streptococci. Compared to the IgG1 monomer, the oligomer was significantly more effective at protecting neonatal rats from infection in vivo. The oligomer was also shown to cross the placenta and to be stable in neonatal rats. Immunochemical analysis and complementary DNA sequencing showed that the transfected cell line produced two distinct kappa light chains: a normal light chain (Ln) with a molecular mass of 25 kilodaltons and a 37-kilodalton species (L37), the domain composition of which was variable-variable-constant (V-V-C). Cotransfection of vectors encoding the heavy chain and L37 resulted in production of oligomeric IgG.
40 CFR 795.225 - Dermal pharmacokinetics of DGBE and DGBA.
Code of Federal Regulations, 2010 CFR
2010-07-01
... this section because they will facilitate the work and improve the reliability of quantitative... for this purpose. (ii) Biotransformation after dermal dosing. Appropriate qualitative and quantitative... tabular form. (2) Evaluation of results. All observed results, quantitative or incidental, shall be...
Daigneault, Pierre-Marc
2014-08-01
Stakeholder participation and evaluation use have attracted a lot of attention from practitioners, theorists and researchers. A common hypothesis is that participation is positively associated with evaluation use. Whereas the number of empirical studies conducted on this topic is impressive, quantitative research has held a minority position within this scientific production. This study mobilizes systematic review methods to 'map' the empirical literature that has quantitatively studied participation and use. The goal is to take stock and assess the strength of evidence of this literature (but not to synthesize the findings) and, based on this assessment, to provide directions for future research. Copyright © 2014 Elsevier Ltd. All rights reserved.
Sachpekidis, Christos; Anwar, Hoda; Winkler, Julia K; Kopp-Schneider, Annette; Larribere, Lionel; Haberkorn, Uwe; Hassel, Jessica C; Dimitrakopoulou-Strauss, Antonia
2018-06-05
Immunotherapy has raised the issue of appropriate treatment response evaluation, due to the unique mechanism of action of the immunotherapeutic agents. Aim of this analysis is to evaluate the potential role of quantitative analysis of 2-deoxy-2-( 18 F)fluoro-D-glucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) data in monitoring of patients with metastatic melanoma undergoing ipilimumab therapy. 25 patients with unresectable metastatic melanoma underwent dynamic PET/CT (dPET/CT) of the thorax and upper abdomen as well as static, whole body PET/CT with 18 F-FDG before the start of ipilimumab treatment (baseline PET/CT), after two cycles of treatment (interim PET/CT) and at the end of treatment after four cycles (late PET/CT). The evaluation of dPET/CT studies was based on semi-quantitative (standardized uptake value, SUV) calculation as well as quantitative analysis, based on two-tissue compartment modeling and a fractal approach. Patients' best clinical response, assessed at a mean of 59 weeks, was used as reference. According to their best clinical response, patients were dichotomized in those demonstrating clinical benefit (CB, n = 16 patients) and those demonstrating no clinical benefit (no-CB, n = 9 patients). No statistically significant differences were observed between CB and no-CB regarding either semi-quantitative or quantitative parameters in all scans. On contrary, the application of the recently introduced PET response evaluation criteria for immunotherapy (PERCIMT) led to a correct classification rate of 84% (21/25 patients). Quantitative analysis of 18 F-FDG PET data does not provide additional information in treatment response evaluation of metastatic melanoma patients receiving ipilimumab. PERCIMT criteria correlated better with clinical response.
Park, Jiyoon; Woo, Ok Hee; Shin, Hye Seon; Cho, Kyu Ran; Seo, Bo Kyoung; Kang, Eun Young
2015-10-01
The purpose of this study is to evaluate the diagnostic performance of SWE in palpable breast mass and to compare with color overlay pattern in SWE with conventional US and quantitative SWE for assessing palpable breast mass. SWE and conventional breast US were performed in 133 women with 156 palpable breast lesions (81 benign, 75 malignant) between August 2013 to June 2014. Either pathology or periodic imaging surveillance more than 2 years was a reference standard. Existence of previous image was blinded to performing radiologists. US BI-RADS final assessment, qualitative and quantitative SWE measurements were evaluated. Diagnostic performances of grayscale US, SWE and US combined to SWE were calculated and compared. Correlation between pattern classification and quantitative SWE was evaluated. Both color overlay pattern and quantitative SWE improved the specificity of conventional US, from 81.48% to 96.30% (p=0.0005), without improvement in sensitivity. Color overlay pattern was significantly related to all quantitative SWE parameters and malignancy rate (p<0.0001.). The optimal cutoff of color overlay pattern was between 2 and 3. Emax with optimal cutoff at 45.1 kPa showed the highest Az value, sensitivity, specificity and accuracy among other quantitative SWE parameters (p<0.0001). Echogenic halo on grayscale US showed significant correlation with color overlay pattern and pathology (p<0.0001). In evaluation of palpable breast mass, conventional US combine to SWE improves specificity and reduces the number of biopsies that ultimately yield a benign result. Color overlay pattern classification is more quick and easy and may represent quantitative SWE measurements with similar diagnostic performances. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Quantitative Analysis of High-Quality Officer Selection by Commandants Career-Level Education Board
2017-03-01
due to Marines being evaluated before the end of their initial service commitment. Our research utilizes quantitative variables to analyze the...not provide detailed information why. B. LIMITATIONS The photograph analysis in this research is strictly limited to a quantitative analysis in...NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA THESIS Approved for public release. Distribution is unlimited. QUANTITATIVE
Quantitative Skills as a Graduate Learning Outcome: Exploring Students' Evaluative Expertise
ERIC Educational Resources Information Center
Matthews, Kelly E.; Adams, Peter; Goos, Merrilyn
2017-01-01
In the biosciences, quantitative skills are an essential graduate learning outcome. Efforts to evidence student attainment at the whole of degree programme level are rare and making sense of such data is complex. We draw on assessment theories from Sadler (evaluative expertise) and Boud (sustainable assessment) to interpret final-year bioscience…
ERIC Educational Resources Information Center
Harlow, Lisa L.; Burkholder, Gary J.; Morrow, Jennifer A.
2002-01-01
Used a structural modeling approach to evaluate relations among attitudes, initial skills, and performance in a Quantitative Methods course that involved students in active learning. Results largely confirmed hypotheses offering support for educational reform efforts that propose actively involving students in the learning process, especially in…
Raman spectral imaging for quantitative contaminant evaluation in skim milk powder
USDA-ARS?s Scientific Manuscript database
This study uses a point-scan Raman spectral imaging system for quantitative detection of melamine in milk powder. A sample depth of 2 mm and corresponding laser intensity of 200 mW were selected after evaluating the penetration of a 785 nm laser through milk powder. Horizontal and vertical spatial r...
In vivo quantitative evaluation of tooth color with hand-held colorimeter and custom template.
Shimada, Kazuki; Kakehashi, Yoshiyuki; Matsumura, Hideo; Tanoue, Naomi
2004-04-01
This article presents a technique for quantitatively evaluating the color of teeth, as well as color change in restorations and tooth surfaces. Through use of a custom template made of a thermoplastic polymer and a dental colorimeter, tooth surface color can be recorded periodically at the same location intraorally.
Evaluating the Effectiveness of Remedial Reading Courses at Community Colleges: A Quantitative Study
ERIC Educational Resources Information Center
Lavonier, Nicole
2014-01-01
The present study evaluated the effectiveness of two instructional approaches for remedial reading courses at a community college. The instructional approaches were strategic reading and traditional, textbook-based instruction. The two research questions that guided the quantitative, quasi-experimental study were: (a) what is the effect of…
The Positive Alternative Credit Experience (PACE) Program a Quantitative Comparative Study
ERIC Educational Resources Information Center
Warren, Rebecca Anne
2011-01-01
The purpose of this quantitative comparative study was to evaluate the Positive Alternative Credit Experience (PACE) Program using an objectives-oriented approach to a formative program evaluation. The PACE Program was a semester-long high school alternative education program designed to serve students at-risk for academic failure or dropping out…
ERIC Educational Resources Information Center
Morris, Ronald W.
2005-01-01
Defining "success" in sexuality education solely in terms of quantitative outcome measures is woefully inadequate. All too often, such measures presuppose and perpetuate a narrow and overly instrumental view of sexuality and education. Research and evaluation favouring quantitative measures of effectiveness tend to amplify short-term results and…
NASA Astrophysics Data System (ADS)
Wang, Ximing; Kim, Bokkyu; Park, Ji Hoon; Wang, Erik; Forsyth, Sydney; Lim, Cody; Ravi, Ragini; Karibyan, Sarkis; Sanchez, Alexander; Liu, Brent
2017-03-01
Quantitative imaging biomarkers are used widely in clinical trials for tracking and evaluation of medical interventions. Previously, we have presented a web based informatics system utilizing quantitative imaging features for predicting outcomes in stroke rehabilitation clinical trials. The system integrates imaging features extraction tools and a web-based statistical analysis tool. The tools include a generalized linear mixed model(GLMM) that can investigate potential significance and correlation based on features extracted from clinical data and quantitative biomarkers. The imaging features extraction tools allow the user to collect imaging features and the GLMM module allows the user to select clinical data and imaging features such as stroke lesion characteristics from the database as regressors and regressands. This paper discusses the application scenario and evaluation results of the system in a stroke rehabilitation clinical trial. The system was utilized to manage clinical data and extract imaging biomarkers including stroke lesion volume, location and ventricle/brain ratio. The GLMM module was validated and the efficiency of data analysis was also evaluated.
Pi, Shan; Cao, Rong; Qiang, Jin Wei; Guo, Yan Hui
2018-01-01
Background Diffusion-weighted imaging (DWI) and quantitative apparent diffusion coefficient (ADC) values are widely used in the differential diagnosis of ovarian tumors. Purpose To assess the diagnostic performance of quantitative ADC values in ovarian tumors. Material and Methods PubMed, Embase, the Cochrane Library, and local databases were searched for studies assessing ovarian tumors using quantitative ADC values. We quantitatively analyzed the diagnostic performances for two clinical problems: benign vs. malignant tumors and borderline vs. malignant tumors. We evaluated diagnostic performances by the pooled sensitivity and specificity values and by summary receiver operating characteristic (SROC) curves. Subgroup analyses were used to analyze study heterogeneity. Results From the 742 studies identified in the search results, 16 studies met our inclusion criteria. A total of ten studies evaluated malignant vs. benign ovarian tumors and six studies assessed malignant vs. borderline ovarian tumors. Regarding the diagnostic accuracy of quantitative ADC values for distinguishing between malignant and benign ovarian tumors, the pooled sensitivity and specificity values were 0.91 and 0.91, respectively. The area under the SROC curve (AUC) was 0.96. For differentiating borderline from malignant tumors, the pooled sensitivity and specificity values were 0.89 and 0.79, and the AUC was 0.91. The methodological quality of the included studies was moderate. Conclusion Quantitative ADC values could serve as useful preoperative markers for predicting the nature of ovarian tumors. Nevertheless, prospective trials focused on standardized imaging parameters are needed to evaluate the clinical value of quantitative ADC values in ovarian tumors.
Analysis of a document/reporting system
NASA Technical Reports Server (NTRS)
Narrow, B.
1971-01-01
An in-depth analysis of the information system within the Data Processing Branch is presented. Quantitative measures are used to evaluate the efficiency and effectiveness of the information system. It is believed that this is the first documented study which utilizes quantitative measures for full scale system analysis. The quantitative measures and techniques for collecting and qualifying the basic data, as described, are applicable to any information system. Therefore this report is considered to be of interest to any persons concerned with the management design, analysis or evaluation of information systems.
Student evaluations of teaching: teaching quantitative courses can be hazardous to one’s career
Smibert, Dylan
2017-01-01
Anonymous student evaluations of teaching (SETs) are used by colleges and universities to measure teaching effectiveness and to make decisions about faculty hiring, firing, re-appointment, promotion, tenure, and merit pay. Although numerous studies have found that SETs correlate with various teaching effectiveness irrelevant factors (TEIFs) such as subject, class size, and grading standards, it has been argued that such correlations are small and do not undermine the validity of SETs as measures of professors’ teaching effectiveness. However, previous research has generally used inappropriate parametric statistics and effect sizes to examine and to evaluate the significance of TEIFs on personnel decisions. Accordingly, we examined the influence of quantitative vs. non-quantitative courses on SET ratings and SET based personnel decisions using 14,872 publicly posted class evaluations where each evaluation represents a summary of SET ratings provided by individual students responding in each class. In total, 325,538 individual student evaluations from a US mid-size university contributed to theses class evaluations. The results demonstrate that class subject (math vs. English) is strongly associated with SET ratings, has a substantial impact on professors being labeled satisfactory vs. unsatisfactory and excellent vs. non-excellent, and the impact varies substantially depending on the criteria used to classify professors as satisfactory vs. unsatisfactory. Professors teaching quantitative courses are far more likely not to receive tenure, promotion, and/or merit pay when their performance is evaluated against common standards. PMID:28503380
Non-animal approaches for toxicokinetics in risk evaluations of food chemicals.
Punt, Ans; Peijnenburg, Ad A C M; Hoogenboom, Ron L A P; Bouwmeester, Hans
2017-01-01
The objective of the present work was to review the availability and predictive value of non-animal toxicokinetic approaches and to evaluate their current use in European risk evaluations of food contaminants, additives and food contact materials, as well as pesticides and medicines. Results revealed little use of quantitative animal or human kinetic data in risk evaluations of food chemicals, compared with pesticides and medicines. Risk evaluations of medicines provided sufficient in vivo kinetic data from different species to evaluate the predictive value of animal kinetic data for humans. These data showed a relatively poor correlation between the in vivo bioavailability in rats and dogs versus that in humans. In contrast, in vitro (human) kinetic data have been demonstrated to provide adequate predictions of the fate of compounds in humans, using appropriate in vitro-in vivo scalers and by integration of in vitro kinetic data with in silico kinetic modelling. Even though in vitro kinetic data were found to be occasionally included within risk evaluations of food chemicals, particularly results from Caco-2 absorption experiments and in vitro data on gut-microbial conversions, only minor use of in vitro methods for metabolism and quantitative in vitro-in vivo extrapolation methods was identified. Yet, such quantitative predictions are essential in the development of alternatives to animal testing as well as to increase human relevance of toxicological risk evaluations. Future research should aim at further improving and validating quantitative alternative methods for kinetics, thereby increasing regulatory acceptance of non-animal kinetic data.
Student evaluations of teaching: teaching quantitative courses can be hazardous to one's career.
Uttl, Bob; Smibert, Dylan
2017-01-01
Anonymous student evaluations of teaching (SETs) are used by colleges and universities to measure teaching effectiveness and to make decisions about faculty hiring, firing, re-appointment, promotion, tenure, and merit pay. Although numerous studies have found that SETs correlate with various teaching effectiveness irrelevant factors (TEIFs) such as subject, class size, and grading standards, it has been argued that such correlations are small and do not undermine the validity of SETs as measures of professors' teaching effectiveness. However, previous research has generally used inappropriate parametric statistics and effect sizes to examine and to evaluate the significance of TEIFs on personnel decisions. Accordingly, we examined the influence of quantitative vs. non-quantitative courses on SET ratings and SET based personnel decisions using 14,872 publicly posted class evaluations where each evaluation represents a summary of SET ratings provided by individual students responding in each class. In total, 325,538 individual student evaluations from a US mid-size university contributed to theses class evaluations. The results demonstrate that class subject (math vs. English) is strongly associated with SET ratings, has a substantial impact on professors being labeled satisfactory vs. unsatisfactory and excellent vs. non-excellent, and the impact varies substantially depending on the criteria used to classify professors as satisfactory vs. unsatisfactory. Professors teaching quantitative courses are far more likely not to receive tenure, promotion, and/or merit pay when their performance is evaluated against common standards.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chu, F.S.
1988-05-12
1) A new direct ELISA, which involves the use of a generic type antibody for T-2 toxin and 3-acetyl-neosolaniol-hemisuccinate (3-Ac-NEOS-HS) conjugated to horseradish peroxidase for the analysis of T-2 toxin metabolites, was established. 2) Analysis of 5 metabolites, i.e., T-2 toxin, HT-2, T-2-4ol, 3'-OH-HT-2, NEOS and a mixture of these five toxins, added at toxin concentrations of 50 and 200 ng/mL of urine, revealed that 87% of the added toxins were recovered analytically at both concentrations in the ELISA, and 69% in RIA and the 200 ppb level. 3) A series of monkey urine samples obtained from a metabolic studymore » was subjected to the new ELISA protocol was as well as to RIA. 4) An extensive study to evaluate a fluorometric method, i.e., hit-and-run assay was made. 5) A direct ELISA for deoxynivalenol (DON) was established. 6) Further improvements for the ELISA for saxitoxin were made. 7) New approaches to produce antibody against nivalenol and saxitoxin were made, but the antibody titers were low. 8) Antibody against microcystin (MCS) was obtained from rabbits after immunizing the animals with MCS-BSA conjugate. 9) A chemical method for the preparation of different monoacetoxyscirpenol (MAS) was established. 10) Routine preparation of different immunochemical reagents continued. Phytotoxins Biological warfare agents; Dinoflagellates. (AW)« less
Redwood, Diana; Provost, Ellen; Asay, Elvin; Roberts, Diana; Haverkamp, Donald; Perdue, David; Bruce, Michael G; Sacco, Frank; Espey, David
2014-04-10
Alaska Native colorectal cancer (CRC) incidence and mortality rates are the highest of any ethnic/racial group in the United States. CRC screening using guaiac-based fecal occult blood tests (gFOBT) are not recommended for Alaska Native people because of false-positive results associated with a high prevalence of Helicobacter pylori-associated hemorrhagic gastritis. This study evaluated whether the newer immunochemical FOBT (iFOBT) resulted in a lower false-positive rate and higher specificity for detecting advanced colorectal neoplasia than gFOBT in a population with elevated prevalence of H. pylori infection. We used a population-based sample of 304 asymptomatic Alaska Native adults aged 40 years or older undergoing screening or surveillance colonoscopy (April 2008-January 2012). Specificity differed significantly (P < .001) between gFOBT (76%; 95% CI, 71%-81%) and iFOBT (92%; 95% CI, 89%-96%). Among H. pylori-positive participants (54%), specificity of iFOBT was even higher (93% vs 69%). Overall, sensitivity did not differ significantly (P = .73) between gFOBT (29%) and iFOBT (36%). Positive predictive value was 11% for gFOBT and 32% for iFOBT. The iFOBT had a significantly higher specificity than gFOBT, especially in participants with current H. pylori infection. The iFOBT represents a potential strategy for expanding CRC screening among Alaska Native and other populations with elevated prevalence of H. pylori, especially where access to screening endoscopy is limited.
NASA Astrophysics Data System (ADS)
Gajos, Katarzyna; Budkowski, Andrzej; Tsialla, Zoi; Petrou, Panagiota; Awsiuk, Kamil; Dąbczyński, Paweł; Bernasik, Andrzej; Rysz, Jakub; Misiakos, Konstantinos; Raptis, Ioannis; Kakabakos, Sotirios
2017-07-01
Mass fabrication of integrated biosensors on silicon chips is facilitated by contact pin-printing, applied for biofunctionalization of individual Si3N4-based transducers at wafer-scale. To optimize the biofunctionalization for immunochemical (competitive) detection of fungicide thiabendazole (TBZ), Si3N4 surfaces are modified with (3-aminopropyl)triethoxysilane and examined after: immobilization of BSA-TBZ conjugate (probe) from solutions with different concentration, blocking with bovine serum albumin (BSA), and immunoreaction with a mouse monoclonal antibody against TBZ. Nanostructure, surface density, probe composition and coverage uniformity of protein layers are evaluated with Atomic Force Microscopy, Spectroscopic Ellipsometry, Time-of-Flight Secondary Ion Mass Spectrometry and X-ray Photoelectron Spectroscopy. Contact pin-printing of overlapping probe spots is compared with hand spotted areas. Contact pin-printing resulted in two-fold increase of immobilized probe surface density as compared to hand spotting. Regarding BSA-TBZ immobilization, an incomplete monolayer develops into a bilayer as the concentration of BSA-TBZ molecules in the printing solution increases from 25 to 100 μg/mL. Upon blocking, however, a complete protein monolayer is formed for all the BSA-TBZ concentrations used. Free surface sites are filled with BSA for low surface coverage with BSA-TBZ, whereas loosely bound BSA-TBZ molecules are removed from the BSA-TBZ bilayer. As a consequence immunoreaction efficiency increases with the printing probe concentration.
McFerran, Ethna; O'Mahony, James F; Fallis, Richard; McVicar, Duncan; Zauber, Ann G; Kee, Frank
2017-01-01
Lifetime risk of developing colorectal cancer is 5%, and 5-year survival at early stage is 92%. Individuals with precancerous lesions removed at primary screening are typically recommended surveillance colonoscopy. Because greater benefits are anticipated for those with higher risk of colorectal cancer, scope for risk-specific surveillance recommendations exists. This review assesses published cost-effectiveness estimates of postpolypectomy surveillance to consider the potential for personalized recommendations by risk group. Meta-analyses of incidence of advanced neoplasia postpolypectomy for low-risk cases were comparable to those without adenoma, with both rates under the lifetime risk of 5%. This group may not benefit from intensive surveillance, which risks unnecessary harm and inefficient use of often scarce colonoscopy capacity. Therefore, greater personalization through deintensified strategies for low-risk individuals could be beneficial. The potential for noninvasive testing, such as fecal immunochemical tests, combined with primary prevention or chemoprevention may reserve colonoscopy for targeted use in personalized risk-stratified surveillance. This review appraised evidence supporting a program of personalized surveillance in patients with colorectal adenoma according to risk group and compared the effectiveness of surveillance colonoscopy with alternative prevention strategies. It assessed trade-offs among costs, benefits, and adverse effects that must be considered in a decision to adopt or reject personalized surveillance. © The Author 2017. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Qamar, Irmeen; Rehman, Suhailur; Mehdi, Ghazala; Maheshwari, Veena; Ansari, Hena A; Chauhan, Sunanda
2018-01-01
Cytologic examination of body fluids commonly involves the use of direct or sediment smears, cytocentrifuge preparations, membrane filter preparations, or cell block sections. Cytospin and cell block techniques are extremely useful in improving cell yield of thin serous effusions and urine samples, and ensure high diagnostic efficacy. We studied cytospin preparations and cell block sections prepared from 180 samples of body fluids and urine samples to compare the relative efficiency of cell retrieval, preservation of cell morphology, ease of application of special stains, and diagnostic efficacy. Samples were collected and processed to prepare cytospin smears and cell block sections. We observed that overall, cell yield and preservation of individual cell morphology were better in cytospin preparations as compared to cell blocks, while preservation of architectural pattern was better in cell block sections. The number of suspicious cases also decreased on cell block sections, with increased detection of malignancy. It was difficult to prepare cell blocks from urine samples due to low cellularity. Cytospin technology is a quick, efficient, and cost-effective method of increasing cell yield in hypocellular samples, with better preservation of cell morphology. Cell blocks are better prepared from high cellularity fluids; however, tissue architecture is better studied, with improved rate of diagnosis and decrease in ambiguous results. Numerous sections can be prepared from a small amount of material. Special stains and immunochemical stains can be easily applied to cell blocks. It also provides a source of archival material.
Optical resonance-enhanced absorption-based near-field immunochip biosensor for allergen detection.
Maier, Irene; Morgan, Michael R A; Lindner, Wolfgang; Pittner, Fritz
2008-04-15
An optical immunochip biosensor has been developed as a rapid method for allergen detection in complex food matrixes, and its application evaluated for the detection of the egg white allergens, ovalbumin and ovomucoid. The optical near-field phenomenon underlying the basic principle of the sensor design is called resonance-enhanced absorption (REA), which utilizes gold nanoparticles (Au NPs) as signal transducers in a highly sensitive interferometric setup. Using this approach, a novel, simple, and rapid colorimetric solid-phase immunoassay on a planar chip substrate was realized in direct and sandwich assay formats, with a detection system that does not require any instrumentation for readout. Semiquantitative immunochemical responses are directly visible to the naked eye of the analyst. The biosensor shows concentration-dependent color development by capturing antibody-functionalized Au NPs on allergen-coated chips and has a detection limit of 1 ng/mL. To establish a rapid method, we took advantage of the physicochemical microenvironment of the Au NP-antibody bioconjugate to be bound directly over an interacting poly(styrene-methyl methacrylate) interlayer by an immobilized antigen. In the direct assay format, a coating time with allergen of only 5 min under "soft" nondenaturing conditions was sufficient for accurate reproducibility and sensitivity. In conclusion, the REA-based immunochip sensor is easy to fabricate, is reproducible and selective in its performance, has minimal technical requirements, and will enable high-throughput screening of affinity binding interactions in technological and medical applications.
Hyaluronic acid concentration in liver diseases.
Gudowska, Monika; Gruszewska, Ewa; Panasiuk, Anatol; Cylwik, Bogdan; Flisiak, Robert; Świderska, Magdalena; Szmitkowski, Maciej; Chrostek, Lech
2016-11-01
The aim of this study was to evaluate the effect of liver diseases of different etiologies and clinical severity of liver cirrhosis on the serum level of hyaluronic acid. The results were compared with noninvasive markers of liver fibrosis: APRI, GAPRI, HAPRI, FIB-4 and Forn's index. Serum samples were obtained from 20 healthy volunteers and patients suffering from alcoholic cirrhosis (AC)-57 patients, non-alcoholic cirrhosis (NAC)-30 and toxic hepatitis (HT)-22. Cirrhotic patients were classified according to Child-Pugh score. Hyaluronic acid concentration was measured by the immunochemical method. Non-patented indicators were calculated using special formulas. The mean serum hyaluronic acid concentration was significantly higher in AC, NAC and HT group in comparison with the control group. There were significant differences in the serum hyaluronic acid levels between liver diseases, and in AC they were significantly higher than those in NAC and HT group. The serum hyaluronic acid level differs significantly due to the severity of cirrhosis and was the highest in Child-Pugh class C. The sensitivity, specificity, accuracy, positive and negative predictive values and the area under the ROC curve for hyaluronic acid and all non-patented algorithms were high and similar to each other. We conclude that the concentration of hyaluronic acid changes in liver diseases and is affected by the severity of liver cirrhosis. Serum hyaluronic acid should be considered as a good marker for noninvasive diagnosis of liver damage, but the combination of markers is more useful.
Changes in membrane cholesterol affect caveolin-1 localization and ICC-pacing in mouse jejunum.
Daniel, E E; Bodie, Gregory; Mannarino, Marco; Boddy, Geoffrey; Cho, Woo-Jung
2004-07-01
Pacing of mouse is dependent on the spontaneous activity of interstitial cells of Cajal in the myenteric plexus (ICC-MP). These ICC, as well as intestinal smooth muscle, contain small membrane invaginations called caveolae. Caveolae are signaling centers formed by insertions of caveolin proteins in the inner aspect of the plasma membrane. Caveolins bind signaling proteins and thereby negatively modulate their signaling. We disrupted caveolae by treating intestinal segments with methyl beta-clodextrin (CD) to remove cholesterol or with water-soluble cholesterol (WSC) to load cholesterol. Both of these treatments reduced pacing frequencies, and these effects were reversed by the other agent. These treatments also inhibited paced contractions, but complete reversal was not observed. To evaluate the specificity of the effects of CD and WSC, additional studies were made of their effects on responses to carbamoyl choline and to stimulation of cholinergic nerves. Neither of these treatments affected these sets of responses compared with their respective time controls. Immunochemical and ultrastructural studies showed that caveolin 1 was present in smooth muscle membranes and ICC-MP. CD depleted both caveolin 1 and caveolae, whereas WSC increased the amount of caveolin 1 immunoreactivity and altered its distribution but failed to increase the number of caveolae. The effects of each agent were reversed in major part by the other. We conclude that signaling through caveolae may play a role in pacing by ICC but does not affect responses to acetylcholine from nerves or when added exogenously.
Nixon, Gavin J; Svenstrup, Helle F; Donald, Carol E; Carder, Caroline; Stephenson, Judith M; Morris-Jones, Stephen; Huggett, Jim F; Foy, Carole A
2014-12-01
Molecular diagnostic measurements are currently underpinned by the polymerase chain reaction (PCR). There are also a number of alternative nucleic acid amplification technologies, which unlike PCR, work at a single temperature. These 'isothermal' methods, reportedly offer potential advantages over PCR such as simplicity, speed and resistance to inhibitors and could also be used for quantitative molecular analysis. However there are currently limited mechanisms to evaluate their quantitative performance, which would assist assay development and study comparisons. This study uses a sexually transmitted infection diagnostic model in combination with an adapted metric termed isothermal doubling time (IDT), akin to PCR efficiency, to compare quantitative PCR and quantitative loop-mediated isothermal amplification (qLAMP) assays, and to quantify the impact of matrix interference. The performance metric described here facilitates the comparison of qLAMP assays that could assist assay development and validation activities.
Soman, S; Liu, Z; Kim, G; Nemec, U; Holdsworth, S J; Main, K; Lee, B; Kolakowsky-Hayner, S; Selim, M; Furst, A J; Massaband, P; Yesavage, J; Adamson, M M; Spincemallie, P; Moseley, M; Wang, Y
2018-04-01
Identifying cerebral microhemorrhage burden can aid in the diagnosis and management of traumatic brain injury, stroke, hypertension, and cerebral amyloid angiopathy. MR imaging susceptibility-based methods are more sensitive than CT for detecting cerebral microhemorrhage, but methods other than quantitative susceptibility mapping provide results that vary with field strength and TE, require additional phase maps to distinguish blood from calcification, and depict cerebral microhemorrhages as bloom artifacts. Quantitative susceptibility mapping provides universal quantification of tissue magnetic property without these constraints but traditionally requires a mask generated by skull-stripping, which can pose challenges at tissue interphases. We evaluated the preconditioned quantitative susceptibility mapping MR imaging method, which does not require skull-stripping, for improved depiction of brain parenchyma and pathology. Fifty-six subjects underwent brain MR imaging with a 3D multiecho gradient recalled echo acquisition. Mask-based quantitative susceptibility mapping images were created using a commonly used mask-based quantitative susceptibility mapping method, and preconditioned quantitative susceptibility images were made using precondition-based total field inversion. All images were reviewed by a neuroradiologist and a radiology resident. Ten subjects (18%), all with traumatic brain injury, demonstrated blood products on 3D gradient recalled echo imaging. All lesions were visible on preconditioned quantitative susceptibility mapping, while 6 were not visible on mask-based quantitative susceptibility mapping. Thirty-one subjects (55%) demonstrated brain parenchyma and/or lesions that were visible on preconditioned quantitative susceptibility mapping but not on mask-based quantitative susceptibility mapping. Six subjects (11%) demonstrated pons artifacts on preconditioned quantitative susceptibility mapping and mask-based quantitative susceptibility mapping; they were worse on preconditioned quantitative susceptibility mapping. Preconditioned quantitative susceptibility mapping MR imaging can bring the benefits of quantitative susceptibility mapping imaging to clinical practice without the limitations of mask-based quantitative susceptibility mapping, especially for evaluating cerebral microhemorrhage-associated pathologies, such as traumatic brain injury. © 2018 by American Journal of Neuroradiology.
ERIC Educational Resources Information Center
Jenkins, Craig
2015-01-01
This paper is a comparative quantitative evaluation of an approach to teaching poetry in the subject domain of English that employs a "guided discovery" pedagogy using computer-based microworlds. It uses a quasi-experimental design in order to measure performance gains in computational thinking and poetic thinking following a…
Evaluation of reference genes for quantitative RT-PCR in Lolium temulentum under abiotic stress
USDA-ARS?s Scientific Manuscript database
Lolium temulentum is a valuable model grass species for the study of stress in forage and turf grasses. Gene expression analysis by quantitative real time RT-PCR relies on the use of proper internal standards. The aim of this study was to identify and evaluate reference genes for use in real-time q...
Kiseleva, N M; Novoseletskaya, A V; Voevodina, Ye B; Kozlov, I G; Inozemtsev, A N
2012-12-01
Apart from restoration of disordered immunological parameters, tactivin and derinat exhibit a pronounced effect on the higher integrative functions of the brain. Experiments on Wistar rats have shown that these drugs accelerated conditioning of food and defense responses. New methods for quantitative evaluation of memory trace consolidation are proposed.
A Framework for Quantitative Evaluation of Care Coordination Effectiveness
ERIC Educational Resources Information Center
Liu, Wei
2017-01-01
The U.S. healthcare system lacks incentives and quantitative evaluation tools to assess coordination in a patient's care transition process. This is needed because poor care coordination has been identified by many studies as one of the major root causes for the U.S. health system's inefficiency, for poor outcomes, and for high cost. Despite…
ERIC Educational Resources Information Center
Jenkins-Guarnieri, Michael A.; Horne, Melissa M.; Wallis, Aaron L.; Rings, Jeffrey A.; Vaughan, Angela L.
2015-01-01
In the present study, we conducted a quantitative evaluation of a novel First Year Seminar (FYS) program with a coordinated curriculum implemented at a public, four-year university to assess its potential role in undergraduate student persistence decisions and academic success. Participants were 2,188 first-year students, 342 of whom completed the…
Tang, L.; Sun, Y.; Buelow, D.; Gu, Z.; Caliendo, A. M.; Pounds, S.
2016-01-01
Given recent advances in the development of quantitative standards, particularly WHO international standards, efforts to better understand the commutability of reference materials have been made. Existing approaches in evaluating commutability include prediction intervals and correspondence analysis; however, the results obtained from existing approaches may be ambiguous. We have developed a “deviation-from-ideal” (DFI) approach to evaluate commutability of standards and applied it to the assessment of Epstein-Bar virus (EBV) load testing in four quantitative PCR assays, treating digital PCR as a reference assay. We then discuss advantages and limitations of the DFI approach as well as experimental design to best evaluate the commutability of an assay in practice. PMID:27076654
Ren, Wei-Wei; Li, Xiao-Long; Wang, Dan; Liu, Bo-Ji; Zhao, Chong-Ke; Xu, Hui-Xiong
2018-04-13
To evaluate a special kind of ultrasound (US) shear wave elastography for differential diagnosis of breast lesions, using a new qualitative analysis (i.e. the elasticity score in the travel time map) compared with conventional quantitative analysis. From June 2014 to July 2015, 266 pathologically proven breast lesions were enrolled in this study. The maximum, mean, median, minimum, and standard deviation of shear wave speed (SWS) values (m/s) were assessed. The elasticity score, a new qualitative feature, was evaluated in the travel time map. The area under the receiver operating characteristic (AUROC) curves were plotted to evaluate the diagnostic performance of both qualitative and quantitative analyses for differentiation of breast lesions. Among all quantitative parameters, SWS-max showed the highest AUROC (0.805; 95% CI: 0.752, 0.851) compared with SWS-mean (0.786; 95% CI:0.732, 0.834; P = 0.094), SWS-median (0.775; 95% CI:0.720, 0.824; P = 0.046), SWS-min (0.675; 95% CI:0.615, 0.731; P = 0.000), and SWS-SD (0.768; 95% CI:0.712, 0.817; P = 0.074). The AUROC of qualitative analysis in this study obtained the best diagnostic performance (0.871; 95% CI: 0.825, 0.909, compared with the best parameter of SWS-max in quantitative analysis, P = 0.011). The new qualitative analysis of shear wave travel time showed the superior diagnostic performance in the differentiation of breast lesions in comparison with conventional quantitative analysis.
The Relationship between Quantitative and Qualitative Measures of Writing Skills.
ERIC Educational Resources Information Center
Howerton, Mary Lou P.; And Others
The relationships of quantitative measures of writing skills to overall writing quality as measured by the E.T.S. Composition Evaluation Scale (CES) were examined. Quantitative measures included indices of language productivity, vocabulary diversity, spelling, and syntactic maturity. Power of specific indices to account for variation in overall…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-18
... lending test rating, and the other addresses the quantitative consideration given to a certain type of... activities would receive when examiners considered them, not the quantitative consideration that those... quantitative) in the institution's CRA evaluation. As a result, such financial institutions may have been...
Quantitative Research Attitudes and Research Training Perceptions among Master's-Level Students
ERIC Educational Resources Information Center
Steele, Janeé M.; Rawls, Glinda J.
2015-01-01
This study explored master's-level counseling students' (N = 804) perceptions of training in the Council for Accreditation of Counseling and Related Educational Programs (2009) Research and Program Evaluation standard, and their attitudes toward quantitative research. Training perceptions and quantitative research attitudes were low to moderate,…
Yamamoto, Tatsuki; Miura, Chihiro; Fuji, Masako; Nagata, Shotaro; Otani, Yuria; Yagame, Takahiro; Yamato, Masahide; Kaminaka, Hironori
2017-02-21
In nature, orchid plants depend completely on symbiotic fungi for their nutrition at the germination and the subsequent seedling (protocorm) stages. However, only limited quantitative methods for evaluating the orchid-fungus interactions at the protocorm stage are currently available, which greatly constrains our understanding of the symbiosis. Here, we aimed to improve and integrate quantitative evaluations of the growth and fungal colonization in the protocorms of a terrestrial orchid, Blettila striata, growing on a plate medium. We achieved both symbiotic and asymbiotic germinations for the terrestrial orchid B. striata. The protocorms produced by the two germination methods grew almost synchronously for the first three weeks. At week four, however, the length was significantly lower in the symbiotic protocorms. Interestingly, the dry weight of symbiotic protocorms did not significantly change during the growth period, which implies that there was only limited transfer of carbon compounds from the fungus to the protocorms in this relationship. Next, to evaluate the orchid-fungus interactions, we developed an ink-staining method to observe the hyphal coils in protocorms without preparing thin sections. Crushing the protocorm under the coverglass enables us to observe all hyphal coils in the protocorms with high resolution. For this observation, we established a criterion to categorize the stages of hyphal coils, depending on development and degradation. By counting the symbiotic cells within each stage, it was possible to quantitatively evaluate the orchid-fungus symbiosis. We describe a method for quantitative evaluation of orchid-fungus symbiosis by integrating the measurements of plant growth and fungal colonization. The current study revealed that although fungal colonization was observed in the symbiotic protocorms, the weight of the protocorm did not significantly increase, which is probably due to the incompatibility of the fungus in this symbiosis. These results suggest that fungal colonization and nutrition transfer can be differentially regulated in the symbiosis. The evaluation methods developed in this study can be used to study various quantitative aspects of the orchid-fungus symbiosis.
Engelberg, Jesse A.; Giberson, Richard T.; Young, Lawrence J.T.; Hubbard, Neil E.
2014-01-01
Microwave methods of fixation can dramatically shorten fixation times while preserving tissue structure; however, it remains unclear if adequate tissue antigenicity is preserved. To assess and validate antigenicity, robust quantitative methods and animal disease models are needed. We used two mouse mammary models of human breast cancer to evaluate microwave-assisted and standard 24-hr formalin fixation. The mouse models expressed four antigens prognostic for breast cancer outcome: estrogen receptor, progesterone receptor, Ki67, and human epidermal growth factor receptor 2. Using pathologist evaluation and novel methods of quantitative image analysis, we measured and compared the quality of antigen preservation, percentage of positive cells, and line plots of cell intensity. Visual evaluations by pathologists established that the amounts and patterns of staining were similar in tissues fixed by the different methods. The results of the quantitative image analysis provided a fine-grained evaluation, demonstrating that tissue antigenicity is preserved in tissues fixed using microwave methods. Evaluation of the results demonstrated that a 1-hr, 150-W fixation is better than a 45-min, 150-W fixation followed by a 15-min, 650-W fixation. The results demonstrated that microwave-assisted formalin fixation can standardize fixation times to 1 hr and produce immunohistochemistry that is in every way commensurate with longer conventional fixation methods. PMID:24682322
Kitamura, Yutaka; Isobe, Kazushige; Kawabata, Hideo; Tsujino, Tetsuhiro; Watanabe, Taisuke; Nakamura, Masayuki; Toyoda, Toshihisa; Okudera, Hajime; Okuda, Kazuhiro; Nakata, Koh; Kawase, Tomoyuki
2018-06-18
Platelet activation and aggregation have been conventionally evaluated using an aggregometer. However, this method is suitable for short-term but not long-term quantitative evaluation of platelet aggregation, morphological changes, and/or adhesion to specific materials. The recently developed digital holographic microscopy (DHM) has enabled the quantitative evaluation of cell size and morphology without labeling or destruction. Thus, we aim to validate its applicability in quantitatively evaluating changes in cell morphology, especially in the aggregation and spreading of activated platelets, thus modifying typical image analysis procedures to suit aggregated platelets. Freshly prepared platelet-rich plasma was washed with phosphate-buffered saline and treated with 0.1% CaCl 2 . Platelets were then fixed and subjected to DHM, scanning electron microscopy (SEM), atomic force microscopy, optical microscopy, and flow cytometry (FCM). Tightly aggregated platelets were identified as single cells. Data obtained from time-course experiments were plotted two-dimensionally according to the average optical thickness versus attachment area and divided into four regions. The majority of the control platelets, which supposedly contained small and round platelets, were distributed in the lower left region. As activation time increased, however, this population dispersed toward the upper right region. The distribution shift demonstrated by DHM was essentially consistent with data obtained from SEM and FCM. Therefore, DHM was validated as a promising device for testing platelet function given that it allows for the quantitative evaluation of activation-dependent morphological changes in platelets. DHM technology will be applicable to the quality assurance of platelet concentrates, as well as diagnosis and drug discovery related to platelet functions. Copyright © 2018 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beck, R.N.; Cooper, M.D.
1990-09-01
This report summarizes goals and accomplishments of the research program supported under DOE Grant No. FG02-86ER60418 entitled Instrumentation and Quantitative Methods of Evaluation, with R. Beck, P. I. and M. Cooper, Co-P.I. during the period January 15, 1990 through September 1, 1990. This program addresses the problems involving the basic science and technology underlying the physical and conceptual tools of radioactive tracer methodology as they relate to the measurement of structural and functional parameters of physiologic importance in health and disease. The principal tool is quantitative radionuclide imaging. The overall objective of this program is to further the development andmore » transfer of radiotracer methodology from basic theory to routine clinical practice in order that individual patients and society as a whole will receive the maximum net benefit from the new knowledge gained. The focus of the research is on the development of new instruments and radiopharmaceuticals, and the evaluation of these through the phase of clinical feasibility. 7 figs.« less
Quantitative Appearance Inspection for Film Coated Tablets.
Yoshino, Hiroyuki; Yamashita, Kazunari; Iwao, Yasunori; Noguchi, Shuji; Itai, Shigeru
2016-01-01
The decision criteria for the physical appearance of pharmaceutical products are subjective and qualitative means of evaluation that are based entirely on human interpretation. In this study, we have developed a comprehensive method for the quantitative analysis of the physical appearance of film coated tablets. Three different kinds of film coated tablets with considerable differences in their physical appearances were manufactured as models, and their surface roughness, contact angle, color measurements and physicochemical properties were investigated as potential characteristics for the quantitative analysis of their physical appearance. All of these characteristics were useful for the quantitative evaluation of the physical appearances of the tablets, and could potentially be used to establish decision criteria to assess the quality of tablets. In particular, the analysis of the surface roughness and film coating properties of the tablets by terahertz spectroscopy allowed for an effective evaluation of the tablets' properties. These results indicated the possibility of inspecting the appearance of tablets during the film coating process.
Li, Dong-tao; Ling, Chang-quan; Zhu, De-zeng
2007-07-01
To establish a quantitative model for evaluating the degree of the TCM basic syndromes often encountered in patients with primary liver cancer (PLC). Medical literatures concerning the clinical investigation and TCM syndrome of PLC were collected and analyzed adopting expert-composed symposium method, and the 100 millimeter scaling was applied in combining with scoring on degree of symptoms to establish a quantitative criterion for symptoms and signs degree classification in patients with PLC. Two models, i.e. the additive model and the additive-multiplicative model, were established by using comprehensive analytic hierarchy process (AHP) as the mathematical tool to estimate the weight of the criterion for evaluating basic syndromes in various layers by specialists. Then the two models were verified in clinical practice and the outcomes were compared with that fuzzy evaluated by specialists. Verification on 459 times/case of PLC showed that the coincidence rate between the outcomes derived from specialists with that from the additive model was 84.53 %, and with that from the additive-multificative model was 62.75 %, the difference between the two showed statistical significance (P<0.01). It could be decided that the additive model is the principle model suitable for quantitative evaluation on the degree of TCM basic syndromes in patients with PLC.
NASA Astrophysics Data System (ADS)
Matsui, Daichi; Ishii, Katsunori; Awazu, Kunio
2015-07-01
Atherosclerosis is a primary cause of critical ischemic diseases like heart infarction or stroke. A method that can provide detailed information about the stability of atherosclerotic plaques is required. We focused on spectroscopic techniques that could evaluate the chemical composition of lipid in plaques. A novel angioscope using multispectral imaging at wavelengths around 1200 nm for quantitative evaluation of atherosclerotic plaques was developed. The angioscope consists of a halogen lamp, an indium gallium arsenide (InGaAs) camera, 3 optical band pass filters transmitting wavelengths of 1150, 1200, and 1300 nm, an image fiber having 0.7 mm outer diameter, and an irradiation fiber which consists of 7 multimode fibers. Atherosclerotic plaque phantoms with 100, 60, 20 vol.% of lipid were prepared and measured by the multispectral angioscope. The acquired datasets were processed by spectral angle mapper (SAM) method. As a result, simulated plaque areas in atherosclerotic plaque phantoms that could not be detected by an angioscopic visible image could be clearly enhanced. In addition, quantitative evaluation of atherosclerotic plaque phantoms based on the lipid volume fractions was performed up to 20 vol.%. These results show the potential of a multispectral angioscope at wavelengths around 1200 nm for quantitative evaluation of the stability of atherosclerotic plaques.
Quantitative evaluation of the voice range profile in patients with voice disorder.
Ikeda, Y; Masuda, T; Manako, H; Yamashita, H; Yamamoto, T; Komiyama, S
1999-01-01
In 1953, Calvet first displayed the fundamental frequency (pitch) and sound pressure level (intensity) of a voice on a two-dimensional plane and created a voice range profile. This profile has been used to evaluate clinically various vocal disorders, although such evaluations to date have been subjective without quantitative assessment. In the present study, a quantitative system was developed to evaluate the voice range profile utilizing a personal computer. The area of the voice range profile was defined as the voice volume. This volume was analyzed in 137 males and 175 females who were treated for various dysphonias at Kyushu University between 1984 and 1990. Ten normal subjects served as controls. The voice volume in cases with voice disorders significantly decreased irrespective of the disease and sex. Furthermore, cases having better improvement after treatment showed a tendency for the voice volume to increase. These findings illustrated the voice volume as a useful clinical test for evaluating voice control in cases with vocal disorders.
NASA Astrophysics Data System (ADS)
Shiina, Tsuyoshi; Maki, Tomonori; Yamakawa, Makoto; Mitake, Tsuyoshi; Kudo, Masatoshi; Fujimoto, Kenji
2012-07-01
Precise evaluation of the stage of chronic hepatitis C with respect to fibrosis has become an important issue to prevent the occurrence of cirrhosis and to initiate appropriate therapeutic intervention such as viral eradication using interferon. Ultrasound tissue elasticity imaging, i.e., elastography can visualize tissue hardness/softness, and its clinical usefulness has been studied to detect and evaluate tumors. We have recently reported that the texture of elasticity image changes as fibrosis progresses. To evaluate fibrosis progression quantitatively on the basis of ultrasound tissue elasticity imaging, we introduced a mechanical model of fibrosis progression and simulated the process by which hepatic fibrosis affects elasticity images and compared the results with those clinical data analysis. As a result, it was confirmed that even in diffuse diseases like chronic hepatitis, the patterns of elasticity images are related to fibrous structural changes caused by hepatic disease and can be used to derive features for quantitative evaluation of fibrosis stage.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laevastu, T.
1983-01-01
The effects of fishing on a given species biomass have been quantitatively evaluated. A constant recruitment is assumed in this study, but the evaluation can be computed on any known age distribution of exploitable biomass. Fishing mortality is assumed to be constant with age; however, spawning stress mortality increases with age. When fishing (mortality) increases, the spawning stress mortality decreases relative to total and exploitable biomasses. These changes are quantitatively shown for two species from the Bering Sea - walleye pollock, Theragra chalcogramma, and yellowfin sole, Limanda aspera.
Wastensson, Gunilla; Holmberg, Björn; Johnels, Bo; Barregard, Lars
2013-01-01
Deep brain stimulation (DBS) of the thalamus is a safe and efficient method for treatment of disabling tremor in patient with essential tremor (ET). However, successful tremor suppression after surgery requires careful selection of stimulus parameters. Our aim was to examine the possible use of certain quantitative methods for evaluating the efficacy of thalamic DBS in ET patients in clinical practice, and to compare these methods with traditional clinical tests. We examined 22 patients using the Essential Tremor Rating Scale (ETRS) and quantitative assessment of tremor with the stimulator both activated and deactivated. We used an accelerometer (CATSYS tremor Pen) for quantitative measurement of postural tremor, and a eurythmokinesimeter (EKM) to evaluate kinetic tremor in a rapid pointing task. The efficacy of DBS on tremor suppression was prominent irrespective of the method used. The agreement between clinical rating of postural tremor and tremor intensity as measured by the CATSYS tremor pen was relatively high (rs = 0.74). The agreement between kinetic tremor as assessed by the ETRS and the main outcome variable from the EKM test was low (rs = 0.34). The lack of agreement indicates that the EKM test is not comparable with the clinical test. Quantitative methods, such as the CATSYS tremor pen, could be a useful complement to clinical tremor assessment in evaluating the efficacy of DBS in clinical practice. Future studies should evaluate the precision of these methods and long-term impact on tremor suppression, activities of daily living (ADL) function and quality of life.
Misyura, Maksym; Sukhai, Mahadeo A; Kulasignam, Vathany; Zhang, Tong; Kamel-Reid, Suzanne; Stockley, Tracy L
2018-01-01
Aims A standard approach in test evaluation is to compare results of the assay in validation to results from previously validated methods. For quantitative molecular diagnostic assays, comparison of test values is often performed using simple linear regression and the coefficient of determination (R2), using R2 as the primary metric of assay agreement. However, the use of R2 alone does not adequately quantify constant or proportional errors required for optimal test evaluation. More extensive statistical approaches, such as Bland-Altman and expanded interpretation of linear regression methods, can be used to more thoroughly compare data from quantitative molecular assays. Methods We present the application of Bland-Altman and linear regression statistical methods to evaluate quantitative outputs from next-generation sequencing assays (NGS). NGS-derived data sets from assay validation experiments were used to demonstrate the utility of the statistical methods. Results Both Bland-Altman and linear regression were able to detect the presence and magnitude of constant and proportional error in quantitative values of NGS data. Deming linear regression was used in the context of assay comparison studies, while simple linear regression was used to analyse serial dilution data. Bland-Altman statistical approach was also adapted to quantify assay accuracy, including constant and proportional errors, and precision where theoretical and empirical values were known. Conclusions The complementary application of the statistical methods described in this manuscript enables more extensive evaluation of performance characteristics of quantitative molecular assays, prior to implementation in the clinical molecular laboratory. PMID:28747393
An Elephant in the Room: Bias in Evaluating a Required Quantitative Methods Course
ERIC Educational Resources Information Center
Fletcher, Joseph F.; Painter-Main, Michael A.
2014-01-01
Undergraduate Political Science programs often require students to take a quantitative research methods course. Such courses are typically among the most poorly rated. This can be due, in part, to the way in which courses are evaluated. Students are generally asked to provide an overall rating, which, in turn, is widely used by students, faculty,…
The U.S. EPA is currently evaluating rapid, real-time quantitative PCR (qPCR) methods for determining recreational water quality based on measurements of fecal indicator bacteria DNA sequences. In order to potentially use qPCR for other Clean Water Act needs, such as updating cri...
ERIC Educational Resources Information Center
Day, Roger P.; And Others
A quasi-experimental design with two experimental groups and one control group was used to evaluate the use of two books in the Quantitative Literacy Series, "Exploring Data" and "Exploring Probability." Group X teachers were those who had attended a workshop on the use of the materials and were using the materials during the…
ERIC Educational Resources Information Center
Yamamoto, Tetsuya
2010-01-01
This article discusses the quantitative analysis of verbal expressions of comments from the evaluation committee reviewers for 8 years (FY2001-FY2008) at the Japanese Public Research Institute, National Institute of Advanced Industrial Science and Technology (AIST). First, the terms often appearing in the comment sheets were observed. Moreover,…
ERIC Educational Resources Information Center
Creswell, John W.
2015-01-01
"Educational Research: Planning, Conducting, and Evaluating Quantitative and Qualitative Research" offers a truly balanced, inclusive, and integrated overview of the processes involved in educational research. This text first examines the general steps in the research process and then details the procedures for conducting specific types…
In Vitro Comparison of Adipokine Export Signals.
Sharafi, Parisa; Kocaefe, Y Çetin
2016-01-01
Mammalian cells are widely used for recombinant protein production in research and biotechnology. Utilization of export signals significantly facilitates production and purification processes. 35 years after the discovery of the mammalian export machinery, there still are obscurities regarding the efficiency of the export signals. The aim of this study was the comparative evaluation of the efficiency of selected export signals using adipocytes as a cell model. Adipocytes have a large capacity for protein secretion including several enzymes, adipokines, and other signaling molecules, providing a valid system for a quantitative evaluation. Constructs that expressed N-terminal fusion export signals were generated to express Enhanced Green Fluorescence Protein (EGFP) as a reporter for quantitative and qualitative evaluation. Furthermore, fluorescent microscopy was used to trace the intracellular traffic of the reporter. The export efficiency of six selected proteins secreted from adipocytes was evaluated. Quantitative comparison of intracellular and exported fractions of the recombinant constructs demonstrated a similar efficiency among the studied sequences with minor variations. The export signal of Retinol Binding Protein (RBP4) exhibited the highest efficiency. This study presents the first quantitative data showing variations among export signals, in adipocytes which will help optimization of recombinant protein distribution.
NASA Astrophysics Data System (ADS)
Nuraeni, E.; Rahmat, A.
2018-05-01
Forming of cognitive schemes of plant anatomy concepts is performed by processing of qualitative and quantitative data obtained from microscopic observations. To enhancing student’s quantitative literacy, strategy of plant anatomy course was modified by adding the task to analyze quantitative data produced by quantitative measurement of plant anatomy guided by material course. Participant in this study was 24 biology students and 35 biology education students. Quantitative Literacy test, complex thinking in plant anatomy test and questioner used to evaluate the course. Quantitative literacy capability data was collected by quantitative literacy test with the rubric from the Association of American Colleges and Universities, Complex thinking in plant anatomy by test according to Marzano and questioner. Quantitative literacy data are categorized according to modified Rhodes and Finley categories. The results showed that quantitative literacy of biology education students is better than biology students.
Brown, R.L.; Levi, P.E.; Hodgson, E.; Melancon, M.J.
1996-01-01
Livers from mallards (Anas platyrhynchos) were treated with either -naphthoflavone (50 mg/kg) or phenobarbital (70 mg/kg). Purification of induced hepatic cytochrome P450 was accomplished using both DEAE and hydroxyapatite columns, as well as sodium dodecyl sulfate polyacrylamide gel electrophoresis separation. Polyclonal antibodies to these proteins were then produced in young male New Zealand White rabbits. ?-naphthoflavone (?NF)- and phenobarbital(PB)-treated red-winged blackbird, screech owl, European starling and lesser scaup liver microsomes were analyzed in western blots for species cross-reactivity. Although all four of these avian species exhibited cross-reactivity with antibodies to ?NF-induced mallard P450, all but the lesser scaup revealed a protein of higher molecular weight than that of the ?NF-induced mallard. In addition, only the lesser scaup exhibited cross-reactivity with the anti-PB-induced mallard P450 antibodies.
An Updated Review of Meat Authenticity Methods and Applications.
Vlachos, Antonios; Arvanitoyannis, Ioannis S; Tserkezou, Persefoni
2016-05-18
Adulteration of foods is a serious economic problem concerning most foodstuffs, and in particular meat products. Since high-priced meat demand premium prices, producers of meat-based products might be tempted to blend these products with lower cost meat. Moreover, the labeled meat contents may not be met. Both types of adulteration are difficult to detect and lead to deterioration of product quality. For the consumer, it is of outmost importance to guarantee both authenticity and compliance with product labeling. The purpose of this article is to review the state of the art of meat authenticity with analytical and immunochemical methods with the focus on the issue of geographic origin and sensory characteristics. This review is also intended to provide an overview of the various currently applied statistical analyses (multivariate analysis (MAV), such as principal component analysis, discriminant analysis, cluster analysis, etc.) and their effectiveness for meat authenticity.
Overby, L. R.; Barlow, G. H.; Doi, R. H.; Jacob, Monique; Spiegelman, S.
1966-01-01
Overby, L. R. (University of Illinois, Urbana), G. H. Barlow, R. H. Doi, Monique Jacob, and S. Spiegelman. Comparison of two serologically distinct ribonucleic acid bacteriophages. I. Properties of the viral particle. J. Bacteriol. 91:442–448. 1966.—Two ribonucleic acid (RNA) coliphages, MS-2 and Qβ, have been characterized physically and serologically. MS-2 has an S20, w value of 79, a molecular weight of 3.6 × 106, a density of 1.422, and pH 3.9 as its isoelectric point. Qβ has an S20, w of 84, a molecular weight of 4.2 × 106, a density of 1.439, and an isoelectric point at pH 5.3. One host (Escherichia coli A-19) permits a distinction between the two on the basis of a marked difference in plaque size. They are distinct immunochemically, no serological cross-reaction being detectable. Images PMID:5903109
Monitoring of aflatoxins and ochratoxin A in Czechoslovak human sera by immunoassay
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fukal, L.; Reisnerova, H.
1990-03-01
Since a level of food contamination with aflatoxins and ochratoxin A has been found low in Czechoslovakia, human exposure to these mycotoxins may not be negligible. However, analysis of food samples provides only indirect evidence of mycotoxin ingestion and no evidence about mycotoxin absorption. Direct evidence can only be obtained by analysis of human body fluids. Therefore, the authors decided to carry out a monitoring of aflatoxin and ochratoxin A level in human sera. In general, TLC and HPLC are most commonly used to analyze mycotoxins and its metabolites. The recent development of immunochemical techniques opens the possibility of determiningmore » individual exposure in a relatively large human population. These assays have the advantage of high specificity and sensitivity. Sample through-put is high, and the methods are technically simple and can be performed at low cost.« less
Yu, Z; Wang, T; Luan, X
1997-06-01
Sixty-one laryngeal and hypopharyngeal squamous cell, carcinoma (LC, HPC) tissue slides were immunochemically stained using LSAB method to study epithelium cells. The results demonstrated that (1) intratumor microvessel density (ITMD) in LC and HPC group was higher than that of the benign group (P < 0.05). ITMD was higher in the subgroup of LC and HPC with positive lymph node positive than that with negative lymph nodes. This result suggest that ITMD is relevant not only to the nature of the tumor, but also to lymph node metastasis. The level of ITMD is an important predictive sign of metastasis. (2) The relationship between ITMD and the clinical staging had no statistic significance (P > 0.05). (3) The analysis on the relationship between ITMD and pathologic differentiation indicated that the level of ITMD raised gradually with the lowering of the pathologic differentiation.
NASA Astrophysics Data System (ADS)
Lebedev, A. A.; Davydov, V. Y.; Usachov, D. Y.; Lebedev, S. P.; Smirnov, A. N.; Levitskii, V. S.; Eliseyev, I. A.; Alekseev, P. A.; Dunaevskiy, M. S.; Rybkin, A. G.; Novikov, S. N.; Makarov, Yu N.
2018-01-01
The structural, chemical, and electronic properties of epitaxial graphene films grown by thermal decomposition of the Si-face of a semi-insulating 6H-SiC substrate in an argon environment are studied by Raman spectroscopy, X-ray photoelectron spectroscopy and angle-resolved photoemission. It was demonstrated the possibility of fabrication of the gas and biosensors that is based on grown graphene films. The gas sensors are sufficiently sensitive to NO2 at low concentrations. The biosensor operation was checked using an immunochemical system comprising fluorescein dye and monoclonal anti fluorescein antibodies. The sensor detects fluorescein concentration on a level of 1-10 ng/mL and bovine serum albumin- fluorescein conjugate on a level of 1-5 ng/mL. The proposed device has good prospects for use for early diagnostics of various diseases.
NASA Technical Reports Server (NTRS)
Mehler, W. R.
1983-01-01
The intrinsic and extrinsic connections of the parvicellular reticular formation (PCRF) that have been demonstrated by fiber degeneration studies and studied by more recently introduced horseradish peroxidase retrograde cell labeling are reviewed in an attempt to delimit the connectivity of the region in the PCRF where electrical stimulation produced emesis. Evidence is presented that certain specific functional subdivisions in PCRF such as the salivatory nuclei and the cells which give rise to the vestibular efferent projections can be delimited. An attempt is made to differentiate the sources of brain stem afferent connections with the nucleus of the tractus solitarius, the vagal nucleus and the nucleus ambiguus complex. The literature bearing on the histochemistry of the brain stem is reviewed in a search for clues to possible unique histo- or immunochemical cytological subdivisions in the parvicellular reticular formation.
Goussard, J
1998-10-23
The importance of the receptor level in breast cancer as an indicator of hormone response has been extensively studied for more than 20 years. Besides cytosol-based ligand-binding assays (dextran-coated charcoal assay, DCC), new methods using monoclonal antibodies raised against estrogen and progesterone receptors allow for the detection of receptors both in cytosol extracts (enzyme immunoassay, EIA) and in tissue sections (immunocytochemical assay, ICA). The biochemical assays (DCC and EIA) as well as the immunochemical detection (ICA) have specific qualities and produce original information which is useful for the therapeutic decision. While DCC gives a measure of the receptor level, whatever the real source of synthesis (normal and/or neoplastic tissue), ICA locates the positive cells and their relative proportion in the tumor. Both methods present their own advantages and disadvantages which are summarized in this study.
Determining the Localization of Carbohydrate Active Enzymes Within Gram-Negative Bacteria.
McLean, Richard; Inglis, G Douglas; Mosimann, Steven C; Uwiera, Richard R E; Abbott, D Wade
2017-01-01
Investigating the subcellular location of secreted proteins is valuable for illuminating their biological function. Although several bioinformatics programs currently exist to predict the destination of a trafficked protein using its signal peptide sequence, these programs have limited accuracy and often require experimental validation. Here, we present a systematic method to fractionate gram-negative cells and characterize the subcellular localization of secreted carbohydrate active enzymes (CAZymes). This method involves four parallel approaches that reveal the relative abundance of protein within the cytoplasm, periplasm, outer membrane, and extracellular environment. Cytoplasmic and periplasmic proteins are fractionated by lysis and osmotic shock, respectively. Outer membrane bound proteins are determined by comparing cells before and after exoproteolytic digestion. Extracellularly secreted proteins are collected from the media and concentrated. These four different fractionations can then be probed for the presence and quantity of target proteins using immunochemical methods such as Western blots and ELISAs, or enzyme activity assays.
Cavanaugh, C M; Abbott, M S; Veenhuis, M
1988-10-01
The distribution of the Calvin cycle enzyme ribulose-1,5-bisphosphate carboxylase (RbuP(2)Case; EC 4.1.1.39) was examined by using two immunological methods in tissues of Solemya velum, an Atlantic coast bivalve containing putative chemoautotrophic symbionts. Antibodies elicited by the purified large subunit of RbuP(2)Case from tobacco (Nicotiana tabacum) cross-reacted on immunoblots with a protein of similar molecular mass occurring in extracts of the symbiont-containing gill tissue of S. velum. No cross-reactivity was detected in symbiont-free tissue extracts. The antiserum also cross-reacted in immunoblots with proteins of Thiobacillus neapolitanus, a free-living sulfuroxidizing chemoautotroph whose RbuP(2)Case has been well characterized. In protein A-gold immunoelectron microscopy studies, this antiserum consistently labeled the symbionts but not surrounding host gill tissue, indicating that the symbionts are responsible for the RbuP(2)Case activity.
González-Halphen, Diego; Maslov, Dmitri A
2004-03-01
NADH-ubiquinone oxidoreductase activity is present in mitochondrial lysates of Phytomonas serpens. Rotenone at 2-10 microM inhibited the activity 50-75%, indicating that it belongs to respiratory complex I. The activity was also inhibited 50-60% in the presence of 10-30 nM atovaquone suggesting that inhibition of complex I represents a likely mechanism of the known antileishmanial activity of this drug. The complex was partially purified by chromatography on DEAE-Sepharose CL-6B and gel-filtration on Sepharose CL-2B. The NADH:ubiquinone oxidoreductase activity in this preparation was completely inactivated by 20 nM atovaquone. The partially purified complex was present in a low amount and its subunits could not be discerned by staining with Coomassie. However, one of its components, a homologue of the 39 kDa subunit of the bovine complex I, was identified immunochemically in the original lysate and in the partially purified material.
NASA Technical Reports Server (NTRS)
Spooner, Brian S.; Guikema, James A.; Barnes, Grady
1990-01-01
Alpha-fetoprotein (AFP), a single-chain polypeptide which is synthesized by the liver and yolk sac of the human fetus, provided a model ligand for assessing the effects of microgravity on ligand binding to surface-immobilized model receptor molecules. Monoclonal antibodies, used as receptors for AFP, were immobilized by covalent attachment to latex microparticles. Zero gravity environment was obtained by parabolic flight aboard NASA 930, a modified KC-135 aircraft. Buring the onset of an episode of zero gravity, ligand and receptor were mixed. Timed incubation (20 s) was terminated by centrifugation, the supernatant removed, and microparticies were assessed for bound AFP by immunochemical methods. The extent of binding was not influenced by microgravity, when compared with 1-G controls, which suggests that aberrant cellular activities observed in microgravity are not the simple expression of altered macromolecular interactions.
Identification of distinct telencephalic progenitor pools for neuronal diversity in the amygdala
Hirata, Tsutomu; Li, Peijun; Lanuza, Guillermo M.; Cocas, Laura A.; Huntsman, Molly M.; Corbin, Joshua G.
2009-01-01
Development of the amygdala, a central structure of the limbic system, remains poorly understood. Using mouse as a model, our studies reveal that two spatially distinct and early specified telencephalic progenitor pools marked by the homeodomain transcription factor Dbx1 are major sources of neuronal cell diversity in the mature amygdala. We find that Dbx1+ cells of the ventral pallium (VP) generate excitatory neurons of the basolateral complex and cortical amygdala nuclei. Moreover, Dbx1-derived cells comprise a novel migratory stream that emanates from the preoptic area (POA), a ventral telencephalic domain adjacent to the diencephalic border. The Dbx1+ POA-derived population migrates specifically to the amygdala, and as defined by both immunochemical and electrophysiological criteria, generates a unique subclass of inhibitory neurons in the medial amygdala nucleus. Thus, this POA-derived population represents a novel progenitor pool dedicated to the limbic system. PMID:19136974
Identification of distinct telencephalic progenitor pools for neuronal diversity in the amygdala.
Hirata, Tsutomu; Li, Peijun; Lanuza, Guillermo M; Cocas, Laura A; Huntsman, Molly M; Corbin, Joshua G
2009-02-01
The development of the amygdala, a central structure of the limbic system, remains poorly understood. We found that two spatially distinct and early-specified telencephalic progenitor pools marked by the homeodomain transcription factor Dbx1 are major sources of neuronal cell diversity in the mature mouse amygdala. We found that Dbx1-positive cells of the ventral pallium generate the excitatory neurons of the basolateral complex and cortical amygdala nuclei. Moreover, Dbx1-derived cells comprise a previously unknown migratory stream that emanates from the preoptic area (POA), a ventral telencephalic domain adjacent to the diencephalic border. The Dbx1-positive, POA-derived population migrated specifically to the amygdala and, as defined by both immunochemical and electrophysiological criteria, generated a unique subclass of inhibitory neurons in the medial amygdala nucleus. Thus, this POA-derived population represents a previously unknown progenitor pool dedicated to the limbic system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hamazaki, T.S.; Nagahama, Y.; Iuchi, I.
1989-05-01
A glycoprotein from the liver, which shares epitopes with chorion (egg envelope or zona pellucida) glycoproteins, is present only in the spawning female fish, Oryzias latipes, under natural conditions. This spawning female-specific (SF) substance is distinct from vitellogenin but closely resembles a major glycoprotein component, ZI-3, of the inner layer (zona radiata interna) of the ovarian egg envelope with respect to some biochemical and immunochemical characteristics. Here we report that the (/sup 125/I)SF substance, injected into the abdominal cavity of the spawning female fish, was rapidly transported by the blood circulation into the ovary and incorporated into the inner layermore » of egg envelope of the growing oocytes. The result strongly suggests that the SF substance from the liver is a precursor substance of the major component, ZI-3, of the inner layer of egg envelope in the fish.« less
Tan, A S; Worobec, E A
1993-02-01
We have isolated two alkaline phosphatases (H-AP and L-AP, for high and low molecular mass, respectively) from Pseudomonas aeruginosa PA01. These two enzymes were found to differ in mobility on sodium dodecyl sulphate polyacrylamide gels (H-AP, M(r) = 51,000 and L-AP, M(r) = 39,500), amino-terminal amino acid sequence and did not cross-react. Both enzymes were active as phosphomonoesterases while only L-AP demonstrated any phosphodiesterase activity. Both enzymes were purified from P. aeruginosa grown in phosphate limiting conditions using the same protocol and were identified in both periplasmic and extracellular locations. A low level of H-AP was produced constitutively whereas L-AP was produced only after induction by reduced phosphate concentration in the growth medium. An L-AP-like enzyme has been previously described, however, this is the first report of a second P. aeruginosa alkaline phosphatase.
Immunochemistry of Biliproteins 1
Berns, Donald S.
1967-01-01
Biliproteins were extracted from representatives of the Cyanophyta, Rhodophyta, and Cryptophyta and purified. Both purified and crude biliproteins were used to stimulate rabbit antibody directed specifically against the biliproteins. The antigenic and immunogenic inter-relationships of these proteins were investigated by the Ouchterlony double diffusion technique. C-phycocyanins from all sources were found to be antigenically and immunogenically related and apparently also related to allophycocyanin but not to any of the phycoerythrins. Larger antigenic differences among phycoerythrins from different groups of algae were discovered. The role of aggregation of the individual biliproteins in their immunochemistry was characterized. Attempts were made to determine the phylogenetic significance of these results. The immunochemical aspects of the biliproteins were striking in that protein antigens from vastly different cell types were found to be closely related. This relationship may be interpreted as supporting the suggestion that Rhodophyta evolved from Cyanophyta or from some common ancestral stock. Images PMID:6080871
Label-free impedimetric immunosensor for sensitive detection of ochratoxin A.
Radi, Abd-Elgawad; Muñoz-Berbel, Xavier; Lates, Vasilica; Marty, Jean-Louis
2009-03-15
A novel label-free electrochemical impedimetric immunosensor for sensitive detection of ochratoxin A (OTA) was reported. A two-step reaction protocol was elaborated to modify the gold electrode. The electrode was first derivatized by electrochemical reduction of in situ generated 4-carboxyphenyl diazonium salt (4-CPDS) in acidic aqueous solution yielded stable 4-carboxyphenyl (4-CP) monolayer. The ochratoxin A antibody was then immobilized making use of the carbodiimide chemistry. The steps of the immunosensor elaboration and the immunochemical reaction between ochratoxin A and the surface-bound antibody were interrogated using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The impedance change, due to the specific immuno-interaction at the immunosensor surface was utilized to detect ochratoxin A. The increase in electron-transfer resistance (DeltaR(et)) values was linearly proportional to the concentration of OTA in the range of 1-20ngmL(-1), with a detection limit of 0.5ngmL(-1).
Comparative biochemistry of renins and angiotensins in the vertebrates.
Nakajima, T; Khosla, M C; Sakakibara, S
1978-09-01
Comparative biochemistry of renins and angiotensins was discussed. Renin extracted from hog kidney was different from that from mouse submaxillary glands in immunoreactivity and carbohydrate content. Rat kidney renin was also different from hog kidney renin in the amino acid composition. The presence of big and big-big renins was pointed out immunochemically. These big renins were considered to be precursors of kidney renin. Angiotensins in mammalian and nonmammalian species produced by renal or extrarenal renin have been differentiated by some biochemical and pharmacological criteria. Some of these angiotensins were analyzed sequentially. The replacements of amino acid residues at positions 1, 5, and/or 9 of angiotensin I have been demonstrated in nonmammalian species. Specific pressor activities have been determined using synthetic angiotensins by a 4 point assay in rat. Specific pressor activities of various angiotensins were obtained from the dose-blood pressure-response curves using a single angiotensin sample per assay rat.
Torre, L; Vazquez, J A; Blázquez, E
1986-01-01
The secretory response and immunoreactive heterogeneity of glucagon was investigated in a patient with glucagonoma syndrome. After glucose administration, abnormal insulin release accompanied by glucose intolerance were observed, whereas the high glucagon circulating levels were only partially blocked after glucose or somatostatin infusion. Chromatographic fractionation of plasma samples, before and after arginine administration showed that most of the immunoreactivity eluted as true glucagon. Furthermore, when aliquots of the tumor extracts were fractionated by column chromatography or by polyacrylamide gel electrophoresis, most of the immunoreactivity eluted in the 3,500 molecular weight peak. In contrast with previous reports, our results indicate that neoplasia A cells can also manufacture and release into the bloodstream great amounts of genuine glucagon rather than larger glucagon immunoreactive forms. In spite of such findings, in this patient neither diabetes nor hyperglycemia were present.
Substance P relaxes rat bronchial smooth muscle via epithelial prostanoid synthesis.
Bodelsson, M; Blomquist, S; Caverius, K; Törnebrandt, K
1999-01-01
Substance P is present in bronchial nerve fibres. The physiological actions of substance P are mediated via tachykinin NK(1) receptors. Immunochemical studies have demonstrated tachykinin NK(1) receptors in the rat airway epithelium. To elucidate how epithelial tachykinin NK(1) receptors affect smooth muscle response to substance P. Contractile response of isolated rat bronchial trunk with or without epithelium was recorded. In intact segments precontracted by 5-hydroxytryptamine, relaxation was induced by substance P and the nitric oxide donor, sodium nitroprusside. Removal of the epithelium abolished relaxation induced by substance P but did not affect relaxation induced by sodium nitroprusside. The cyclo-oxygenase inhibitor, indomethacin, but not the nitric oxide synthase inhibitor, L-N(G)-monomethylarginine, reduced the relaxation in response to substance P. Epithelial tachykinin NK(1) receptors mediate substance-P-induced relaxation of rat bronchial smooth muscle via release of prostanoids but not nitric oxide.
Górska, Sabina; Jachymek, Wojciech; Rybka, Jacek; Strus, Magdalena; Heczko, Piotr B; Gamian, Andrzej
2010-01-11
This paper describes the structure of neutral exopolysaccharide (EPS) produced by Lactobacillus johnsonii 142, strain of the lactic acid bacteria isolated from the intestine of mice with experimentally induced inflammatory bowel disease (IBD). Sugar and methylation analyses along with (1)H and (13)C NMR spectroscopy, including two-dimensional (1)H,(1)H COSY, TOCSY, NOESY, and (1)H,(13)C HSQC experiments revealed that the repeating unit of the EPS is a pentasaccharide: -->3)-alpha-D-Galp-(1-->3)-beta-d-Glcp-(1-->5)-beta-D-Galf-(1-->3)-alpha-D-Galp-(1-->3)-alpha-D-Galp-(1--> The rabbit antiserum raised against whole cells of L. johnsonii 142 reacted with homologous EPS, and cross-reacted with exopolysaccharide from Lactobacillus animalis/murinus 148 isolated also from mice with IBD, but not reacted with EPS of L. johnsonii 151 from healthy mice. Copyright 2009 Elsevier Ltd. All rights reserved.