Sample records for quantitative sims analysis

  1. Quantitative analysis of Si1-xGex alloy films by SIMS and XPS depth profiling using a reference material

    NASA Astrophysics Data System (ADS)

    Oh, Won Jin; Jang, Jong Shik; Lee, Youn Seoung; Kim, Ansoon; Kim, Kyung Joong

    2018-02-01

    Quantitative analysis methods of multi-element alloy films were compared. The atomic fractions of Si1-xGex alloy films were measured by depth profiling analysis with secondary ion mass spectrometry (SIMS) and X-ray Photoelectron Spectroscopy (XPS). Intensity-to-composition conversion factor (ICF) was used as a mean to convert the intensities to compositions instead of the relative sensitivity factors. The ICFs were determined from a reference Si1-xGex alloy film by the conventional method, average intensity (AI) method and total number counting (TNC) method. In the case of SIMS, although the atomic fractions measured by oxygen ion beams were not quantitative due to severe matrix effect, the results by cesium ion beam were very quantitative. The quantitative analysis results by SIMS using MCs2+ ions are comparable to the results by XPS. In the case of XPS, the measurement uncertainty was highly improved by the AI method and TNC method.

  2. Secondary Ion Mass Spectrometry SIMS XI

    NASA Astrophysics Data System (ADS)

    Gillen, G.; Lareau, R.; Bennett, J.; Stevie, F.

    2003-05-01

    This volume contains 252 contributions presented as plenary, invited and contributed poster and oral presentations at the 11th International Conference on Secondary Ion Mass Spectrometry (SIMS XI) held at the Hilton Hotel, Walt Disney World Village, Orlando, Florida, 7 12 September, 1997. The book covers a diverse range of research, reflecting the rapid growth in advanced semiconductor characterization, ultra shallow depth profiling, TOF-SIMS and the new areas in which SIMS techniques are being used, for example in biological sciences and organic surface characterization. Papers are presented under the following categories: Isotopic SIMS Biological SIMS Semiconductor Characterization Techniques and Applications Ultra Shallow Depth Profiling Depth Profiling Fundamental/Modelling and Diffusion Sputter-Induced Topography Fundamentals of Molecular Desorption Organic Materials Practical TOF-SIMS Polyatomic Primary Ions Materials/Surface Analysis Postionization Instrumentation Geological SIMS Imaging Fundamentals of Sputtering Ion Formation and Cluster Formation Quantitative Analysis Environmental/Particle Characterization Related Techniques These proceedings provide an invaluable source of reference for both newcomers to the field and experienced SIMS users.

  3. Quantitative analysis of the Ge concentration in a SiGe quantum well: comparison of low-energy RBS and SIMS measurements.

    PubMed

    Krecar, D; Rosner, M; Draxler, M; Bauer, P; Hutter, H

    2006-01-01

    The germanium concentration and the position and thickness of the quantum well in molecular beam epitaxy (MBE)-grown SiGe were quantitatively analyzed via low-energy Rutherford backscattering (RBS) and secondary ion mass spectrometry (SIMS). In these samples, the concentrations of Si and Ge were assumed to be constant, except for the quantum well, where the germanium concentration was lower. The thickness of the analyzed quantum well was about 12 nm and it was situated at a depth of about 60 nm below the surface. A dip showed up in the RBS spectra due to the lower germanium concentration in the quantum well, and this was evaluated. Good depth resolution was required in order to obtain quantitative results, and this was obtained by choosing a primary energy of 500 keV and a tilt angle of 51 degrees with respect to the surface normal. Quantitative information was deduced from the raw data by comparing it with SIMNRA simulated spectra. The SIMS measurements were performed with oxygen primary ions. Given the response function of the SIMS instrument (the SIMS depth profile of the germanium delta (delta) layer), and using the forward convolution (point-to-point convolution) model, it is possible to determine the germanium concentration and the thickness of the analyzed quantum well from the raw SIMS data. The aim of this work was to compare the results obtained via RBS and SIMS and to show their potential for use in the semiconductor and microelectronics industry. The detection of trace elements (here the doping element antimony) that could not be evaluated with RBS in low-energy mode is also demonstrated using SIMS instead.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smentkowski, Vincent S., E-mail: smentkow@ge.com

    Changes in the oxidation state of an element can result in significant changes in the ionization efficiency and hence signal intensity during secondary ion mass spectrometry (SIMS) analysis; this is referred to as the SIMS matrix effect [Secondary Ion Mass Spectrometry: A Practical Handbook for Depth Profiling and Bulk Impurity Analysis, edited by R. G. Wilson, F. A. Stevie, and C. W. Magee (Wiley, New York, 1990)]. The SIMS matrix effect complicates quantitative analysis. Quantification of SIMS data requires the determination of relative sensitivity factors (RSFs), which can be used to convert the as measured intensity into concentration units [Secondarymore » Ion Mass Spectrometry: A Practical Handbook for Depth Profiling and Bulk Impurity Analysis, edited by R. G. Wilson, F. A. Stevie, and C. W. Magee (Wiley, New York, 1990)]. In this manuscript, the authors report both: RSFs which were determined for quantification of B in Si and SiO{sub 2} matrices using a dual beam time of flight secondary ion mass spectrometry (ToF-SIMS) instrument and the protocol they are using to provide quantitative ToF-SIMS images and line scan traces. The authors also compare RSF values that were determined using oxygen and Ar ion beams for erosion, discuss the problems that can be encountered when bulk calibration samples are used to determine RSFs, and remind the reader that errors in molecular details of the matrix (density, volume, etc.) that are used to convert from atoms/cm{sup 3} to other concentration units will propagate into errors in the determined concentrations.« less

  5. The quantitative analysis of OH in vesuvianite: a polarized FTIR and SIMS study

    NASA Astrophysics Data System (ADS)

    Bellatreccia, Fabio; della Ventura, Giancarlo; Ottolini, Luisa; Libowitzky, Eugen; Beran, Anton

    2005-05-01

    A well-characterized suite of vesuvianite samples from the volcanic ejecta (skarn or syenites) from Latium (Italy) was studied by single-crystal, polarized radiation, Fourier-transform infrared (FTIR) spectroscopy and secondary-ion mass-spectrometry (SIMS). OH-stretching FTIR spectra consist of a rather well-defined triplet of broad bands at higher-frequency (3,700 3,300 cm-1) and a very broad composite absorption below 3,300 cm-1. Measurements with E//c or E⊥c show that all bands are strongly polarized with maximum absorption for E//c. They are in agreement with previous band assignments (Groat et al. Can Mineral 33:609, 1995) to the two O(11) H(1) and O(10) H(2) groups in the structure. Pleochroic measurements with changing direction of the E vector of the incident radiation show that the orientation of the O(11) H(1) dipole is OH∧c~35°, in excellent agreement with the neutron data of Lager et al. (Can Mineral 37:763, 1999). A SIMS-based calibration curve at ~10% rel. accuracy has been worked out and used as reference for the quantitative analysis of H2O in vesuvianite by FTIR. Based on previous SIMS results for silicate minerals (Ottolini and Hawthorne in J Anal At Spectrom 16:1266, 2001; Ottolini et al. in Am Mineral 87:1477, 2002) the SiO2 and FeO content of the matrix were assumed as the major factors to be considered at a first approximation in the selection of the standards for H. The lack of vesuvianite standards for quantitative SIMS analysis of H2O has been here overcome by selecting low-silica elbaite crystals (Ottolini et al. in Am Mineral 87:1477, 2002). The resulting integrated molar absorption FTIR coefficient for vesuvianite is ɛi=100.000±2.000 l mol-1 cm-2. SIMS data for Li, B, F, Sr, Y, Be, Ba REE, U and Th are also provided in the paper.

  6. Chromium localization in plant tissues of Lycopersicum esculentum Mill using ICP-MS and ion microscopy (SIMS)

    NASA Astrophysics Data System (ADS)

    Mangabeira, Pedro Antonio; Gavrilov, Konstantin L.; Almeida, Alex-Alan Furtado de; Oliveira, Arno Heeren; Severo, Maria Isabel; Rosa, Tiago Santana; Silva, Delmira da Costa; Labejof, Lise; Escaig, Françoise; Levi-Setti, Riccardo; Mielke, Marcelo Schramm; Loustalot, Florence Grenier; Galle, Pierre

    2006-03-01

    High-resolution imaging secondary ion mass spectrometry (HRI-SIMS) in combination with inductively coupled plasma mass spectrometry (ICP-MS) were utilised to determine specific sites of chromium concentration in tomato plant tissues (roots, stems and leaves). The tissues were obtained from plants grown for 2 months in hydroponic conditions with Cr added in a form chromium salt (CrCl 3·6H 2O) to concentrations of 25 and 50 mg/L. The chemical fixation procedure used permit to localize only insoluble or strongly bound Cr components in tomato plant tissue. In this work no quantitative SIMS analysis was made. HRI-SIMS analysis revealed that the transport of chromium is restricted to the vascular system of roots, stems and leaves. No Cr was detected in epidermis, palisade parenchyma and spongy parenchyma cells of the leaves. The SIMS-300 spectra obtained from the tissues confirm the HRI-SIMS observations. The roots, and especially walls of xylem vessels, were determined as the principal site of chromium accumulation in tomato plants.

  7. Quantitative Surface Analysis of a Binary Drug Mixture—Suppression Effects in the Detection of Sputtered Ions and Post-Ionized Neutrals

    NASA Astrophysics Data System (ADS)

    Karras, Gabriel; Lockyer, Nicholas P.

    2014-05-01

    A systematic mass spectrometric study of two of the most common analgesic drugs, paracetamol and ibuprofen, is reported. The drugs were studied by means of secondary ion mass spectrometry (SIMS) and secondary neutral mass spectrometry (SNMS) using laser post-ionization (LPI) both in pure samples and in a two-component mixture. Ion suppression within the two-component system observed in SIMS mode is ameliorated using LPI under room temperature analysis. However, suppression effects are apparent in LPI mode on performing the analysis at cryogenic temperatures, which we attribute to changes in the desorption characteristics of sputtered molecules, which influences the subsequent post-ionization efficiency. This suggests different mechanisms of ion suppression in SIMS and LPI modes.

  8. High-resolution gas chromatography/mas spectrometry method for characterization and quantitative analysis of ginkgolic acids in ginkgo biloba plants, extracts, and dietary supplements

    USDA-ARS?s Scientific Manuscript database

    A high resolution GC/MS with Selected Ion Monitor (SIM) method focusing on the characterization and quantitative analysis of ginkgolic acids (GAs) in Ginkgo biloba L. plant materials, extracts and commercial products was developed and validated. The method involved sample extraction with (1:1) meth...

  9. Assessment of the ion-trap mass spectrometer for routine qualitative and quantitative analysis of drugs of abuse extracted from urine.

    PubMed

    Vorce, S P; Sklerov, J H; Kalasinsky, K S

    2000-10-01

    The ion-trap mass spectrometer (MS) has been available as a detector for gas chromatography (GC) for nearly two decades. However, it still occupies a minor role in forensic toxicology drug-testing laboratories. Quadrupole MS instruments make up the majority of GC detectors used in drug confirmation. This work addresses the use of these two MS detectors, comparing the ion ratio precision and quantitative accuracy for the analysis of different classes of abused drugs extracted from urine. Urine specimens were prepared at five concentrations each for amphetamine (AMP), methamphetamine (METH), benzoylecgonine (BZE), delta9-carboxy-tetrahydrocannabinol (delta9-THCCOOH), phencyclidine (PCP), morphine (MOR), codeine (COD), and 6-acetylmorphine (6-AM). Concentration ranges for AMP, METH, BZE, delta9-THCCOOH, PCP, MOR, COD, and 6-AM were 50-2500, 50-5000, 15-800, 1.5-65, 1-250, 500-32000, 250-21000, and 1.5-118 ng/mL, respectively. Sample extracts were injected into a GC-quadrupole MS operating in selected ion monitoring (SIM) mode and a GC-ion-trap MS operating in either selected ion storage (SIS) or full scan (FS) mode. Precision was assessed by the evaluation of five ion ratios for n = 15 injections at each concentration using a single-point calibration. Precision measurements for SIM ion ratios provided coefficients of variation (CV) between 2.6 and 9.8% for all drugs. By comparison, the SIS and FS data yielded CV ranges of 4.0-12.8% and 4.0-11.2%, respectively. The total ion ratio failure rates were 0.2% (SIM), 0.7% (SIS), and 1.2% (FS) for the eight drugs analyzed. Overall, the SIS mode produced stable, comparable mean ratios over the concentration ranges examined, but had greater variance within batch runs. Examination of postmortem and quality-control samples produced forensically accurate quantitation by SIS when compared to SIM. Furthermore, sensitivity of FS was equivalent to SIM for all compounds examined except for 6-AM.

  10. Time-of-flight secondary ion mass spectrometry studies of cluster ion analysis for semiconductors and diffusion of manganese in gallium arsenide at low temperatures

    NASA Astrophysics Data System (ADS)

    Goacher, Robyn Elizabeth

    Secondary Ion Mass Spectrometry (SIMS) is an established method for the quantitative analysis of dopants in semiconductors. The quasi-parallel mass acquisition of Time-of-Flight SIMS, along with the development of polyatomic primary ions, have rapidly increased the use of SIMS for analysis of organic and biological specimens. However, the advantages and disadvantages of using cluster primary ions for quantitative analysis of inorganic materials are not clear. The research described in this dissertation investigates the consequences of using polyatomic primary ions for the analysis of inorganic compounds in ToF-SIMS. Furthermore, the diffusion of Mn in GaAs, which is important in Spintronic material applications such as spin injection, is also studied by quantitative ToF-SIMS depth profiling. In the first portion of this work, it was discovered that primary ion bombardment of pre-sputtered compound semiconductors GaAs and InP for the purpose of spectral analysis resulted in the formation of cluster secondary ions, as well as atomic secondary ions (Chapter 2). In particular, bombardment using a cluster primary ion such as Bi3q + or C60q+ resulted in higher yields of high-mass cluster secondary ions. These cluster secondary ions did not have bulk stoichiometry, "non-stoichiometric", in contrast to the paradigm of stoichiometric cluster ions generated from salts. This is attributed to the covalent bonding of the compound semiconductors, as well as to preferential sputtering. The utility of high-mass cluster secondary ions in depth profiling is also discussed. Relative sensitivity factors (RSFs) calculated for ion-implanted Fe and Mn samples in GaAs also exhibit differences based on whether monatomic or polyatomic primary ions are utilized (Chapter 3). These RSFs are important for the quantitative conversion of intensity to concentration. When Bi 32+ primary ions are used for analysis instead of Bi + primary ions, there is a significantly higher proportion of Mn and Fe ions present in the spectra, as referenced to the matrix species. The magnitude of this effect differs depending on the sputtering ion, Cs or C60. The use of C60cluster primary ions for depth profiling of GaAs is also investigated (Chapter 4). In particular, for quantitative depth profiling, parameters such as depth resolution, ion and sputter yields, and relative sensitivity factors are pertinent to profiling thin layered structures quantitatively and quickly. C60 sputtering is compared to Cs sputtering in all of these aspects. It is found that 10 keV C60+ is advantageous for the analysis of metals (such as Au contacts on Si) but that previously reported roughness problems prohibit successful analysis in Si. For Al delta layers and quantum wells in GaAs, C60 q+ sputtering induced very little roughness in the sample, and resulted in high ion yields and excellent signal-to-noise as compared to Cs+ sputtering. However, the depth resolution of C60 is at best equivalent to 1 keV Cs+ and does not extend into the sub 2-nm range. Furthermore, C60 sputtering results in significant carbon implantation. In the second portion of this work, quantitative ToF-SIMS depth profiling was used to evaluate the diffusion of Mn into GaAs. Samples were prepared by Molecular Beam Epitaxy in the department of Physics. Mn diffusion from MnAs was investigated first, and Mn diffusion from layered epitaxial structures of GaAs / Ga1-xMnxAs / GaAs was investigated second. Diffusion experiments were conducted by annealing portions of the samples in sealed glass ampoules at low temperatures (200-400°C). Different sputtering rates were measured for MnAs and GaAs and the measured depth profiles were corrected for these effects. RSFs measured for Mn ion-implanted standards were used to calibrate the intensity scale. For diffusion from MnAs, thin MnAs layers resulted in no measurable changes except in the surface transient. For thick MnAs layers, it was determined that substantial loss of As occurred at 400°C, resulting in severe sample roughening, which inhibited proper SIMS analysis. Results for the diffusion of Mn out of a thick buried layer of Ga1-xMnxAs show that annealing induces diffusion of Mn species from the Ga1-xMnxAs layer into the neighboring GaAs with an activation energy of 0.69+/-0.09 eV. This results in doping of the GaAs layer, which is detrimental to spin injection for Spintronics devices.

  11. Quantitative SIMS Imaging of Agar-Based Microbial Communities.

    PubMed

    Dunham, Sage J B; Ellis, Joseph F; Baig, Nameera F; Morales-Soto, Nydia; Cao, Tianyuan; Shrout, Joshua D; Bohn, Paul W; Sweedler, Jonathan V

    2018-05-01

    After several decades of widespread use for mapping elemental ions and small molecular fragments in surface science, secondary ion mass spectrometry (SIMS) has emerged as a powerful analytical tool for molecular imaging in biology. Biomolecular SIMS imaging has primarily been used as a qualitative technique; although the distribution of a single analyte can be accurately determined, it is difficult to map the absolute quantity of a compound or even to compare the relative abundance of one molecular species to that of another. We describe a method for quantitative SIMS imaging of small molecules in agar-based microbial communities. The microbes are cultivated on a thin film of agar, dried under nitrogen, and imaged directly with SIMS. By use of optical microscopy, we show that the area of the agar is reduced by 26 ± 2% (standard deviation) during dehydration, but the overall biofilm morphology and analyte distribution are largely retained. We detail a quantitative imaging methodology, in which the ion intensity of each analyte is (1) normalized to an external quadratic regression curve, (2) corrected for isomeric interference, and (3) filtered for sample-specific noise and lower and upper limits of quantitation. The end result is a two-dimensional surface density image for each analyte. The sample preparation and quantitation methods are validated by quantitatively imaging four alkyl-quinolone and alkyl-quinoline N-oxide signaling molecules (including Pseudomonas quinolone signal) in Pseudomonas aeruginosa colony biofilms. We show that the relative surface densities of the target biomolecules are substantially different from values inferred through direct intensity comparison and that the developed methodologies can be used to quantitatively compare as many ions as there are available standards.

  12. Quantitative secondary ion mass spectrometric analysis of secondary ion polarity in GaN films implanted with oxygen

    NASA Astrophysics Data System (ADS)

    Hashiguchi, Minako; Sakaguchi, Isao; Adachi, Yutaka; Ohashi, Naoki

    2016-10-01

    Quantitative analyses of N and O ions in GaN thin films implanted with oxygen ions (16O+) were conducted by secondary ion mass spectrometry (SIMS). Positive (CsM+) and negative secondary ions extracted by Cs+ primary ion bombardment were analyzed for oxygen quantitative analysis. The oxygen depth profiles were obtained using two types of primary ion beams: a Gaussian-type beam and a broad spot beam. The oxygen peak concentrations in GaN samples were from 3.2 × 1019 to 7.0 × 1021 atoms/cm3. The depth profiles show equivalent depth resolutions in the two analyses. The intensity of negative oxygen ions was approximately two orders of magnitude higher than that of positive ions. In contrast, the O/N intensity ratio measured using CsM+ molecular ions was close to the calculated atomic density ratio, indicating that the SIMS depth profiling using CsM+ ions is much more effective for the measurements of O and N ions in heavy O-implanted GaN than that using negative ions.

  13. Quantitative determination of major active components in Ginkgo biloba dietary supplements by liquid chromatography/mass spectrometry.

    PubMed

    Ding, Shujing; Dudley, Ed; Plummer, Sue; Tang, Jiandong; Newton, Russell P; Brenton, A Gareth

    2006-01-01

    A reversed-phase high-performance liquid chromatography/electrospray ionisation mass spectrometry (RP-HPLC/ESI-MS) method was developed and validated for the simultaneous determination of ten major active components in Ginkgo biloba extract (bilobalide, ginkgolides A, B, C, quercetin, kaempferol, isorhamnetin, rutin hydrate, quercetin-3-beta-D-glucoside and quercitrin hydrate) which have not been previously reported to be quantified in a single analysis. The ten components exhibit baseline separation in 50 min by C18 chromatography using a water/1:1 (v/v) methanol/acetonitrile gradient. Quantitation was performed using negative ESI-MS in selected ion monitoring (SIM) mode. Good reproducibility and recovery were obtained by this method. The sensitivity of both UV and different mass spectrometry modes (full scan, selected ion monitoring (SIM), and selected reaction monitoring (SRM)) were compared and both quantitation with and without internal standard were evaluated. The analysis of Ginkgo biloba commercial products showed remarkable variations in the rutin and quercetin content as well as the terpene lactone contents although all the products satisfy the conventional quality control method. Copyright 2006 John Wiley & Sons, Ltd.

  14. Authentication of pineapple (Ananas comosus [L.] Merr.) fruit maturity stages by quantitative analysis of γ- and δ-lactones using headspace solid-phase microextraction and chirospecific gas chromatography-selected ion monitoring mass spectrometry (HS-SPME-GC-SIM-MS).

    PubMed

    Steingass, Christof B; Langen, Johannes; Carle, Reinhold; Schmarr, Hans-Georg

    2015-02-01

    Headspace solid phase microextraction and chirospecific gas chromatography-mass spectrometry in selected ion monitoring mode (HS-SPME-GC-SIM-MS) allowed quantitative determination of δ-lactones (δ-C8, δ-C10) and γ-lactones (γ-C6, γ-C8, γ-C10). A stable isotope dilution assay (SIDA) with d7-γ-decalactone as internal standard was used for quantitative analysis of pineapple lactones that was performed at three progressing post-harvest stages of fully ripe air-freighted and green-ripe sea-freighted fruits, covering the relevant shelf-life of the fruits. Fresh pineapples harvested at full maturity were characterised by γ-C6 of high enantiomeric purity remaining stable during the whole post-harvest period. In contrast, the enantiomeric purity of γ-C6 significantly decreased during post-harvest storage of sea-freighted pineapples. The biogenetical background and the potential of chirospecific analysis of lactones for authentication and quality evaluation of fresh pineapple fruits are discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Quantitative SIMS depth profiling of diffusion barrier gate-oxynitride structures in TFT-LCDs.

    PubMed

    Dreer, Sabine; Wilhartitz, Peter; Piplits, Kurt; Mayerhofer, Karl; Foisner, Johann; Hutter, Herbert

    2004-06-01

    Gate oxynitride structures of TFT-LCDs were investigated by SIMS, and successful solutions are demonstrated to overcome difficulties arising due to the charging effects of the multilayer systems, the matrix effect of the method, and the small pattern sizes of the samples. Because of the excellent reproducibility achieved by applying exponential relative sensitivity functions for quantitative analysis, minor differences in the barrier gate-oxynitride composition deposited on molybdenum capped aluminium-neodymium metallisation electrodes were determined between the centre and the edge of the TFT-LCD substrates. No differences were found for molybdenum-tungsten metallisations. Furthermore, at the edge of the glass substrates, aluminium, neodymium, and molybdenum SIMS depth profiles show an exponential trend. With TEM micrographs an inhomogeneous thickness of the molybdenum capping is revealed as the source of this effect, which influences the electrical behaviour of the device. The production process was improved after these results and the aging behaviour of TFT-LCDs was investigated in order to explain the change in control voltage occurring during the lifetime of the displays. SIMS and TEM show an enrichment of neodymium at the interface to the molybdenum layer, confirming good diffusion protection of the molybdenum barrier during accelerated aging. The reason for the shift of the control voltage was finally located by semi-quantitative depth profiling of the sodium diffusion originating from the glass substrate. Molybdenum-tungsten was a much better buffer for the highly-mobile charge carriers than aluminium-neodymium. Best results were achieved with PVD silicon oxynitride as diffusion barrier and gate insulator deposited on aluminium-neodymium metallisation layers.

  16. ToF-SIMS analysis of poly(L-lysine)-graft-poly(2-methyl-2-oxazoline) ultrathin adlayers.

    PubMed

    Pidhatika, Bidhari; Chen, Yin; Coullerez, Geraldine; Al-Bataineh, Sameer; Textor, Marcus

    2014-02-01

    Understanding of the interfacial chemistry of ultrathin polymeric adlayers is fundamentally important in the context of establishing quantitative design rules for the fabrication of nonfouling surfaces in various applications such as biomaterials and medical devices. In this study, seven poly(L-lysine)-graft-poly(2-methyl-2-oxazoline) (PLL-PMOXA) copolymers with grafting density (number of PMOXA chains per lysine residue) 0.09, 0.14, 0.19, 0.33, 0.43, 0.56, and 0.77, respectively, were synthesized and characterized by means of nuclear magnetic resonance spectroscopy (NMR). The copolymers were then adsorbed on Nb2O5 surfaces. Optical waveguide lightmode spectroscopy method was used to monitor the surface adsorption in situ of these copolymers and provide information on adlayer masses that were then converted into PLL and PMOXA surface densities. To investigate the relationship between copolymer bulk architecture (as shown by NMR data) and surface coverage as well as surface architecture, time-of-flight secondary ion mass spectrometry (ToF-SIMS) analysis was performed. Furthermore, ToF-SIMS method combined with principal component analysis (PCA) was used to verify the protein resistant properties of PLL-PMOXA adlayers, by thorough characterization before and after adlayer exposure to human serum. ToF-SIMS analysis revealed that the chemical composition as well as the architecture of the different PLL-PMOXA adlayers indeed reflects the copolymer bulk composition. ToF-SIMS results also indicated a heterogeneous surface coverage of PLL-PMOXA adlayers with high grafting densities higher than 0.33. In the case of protein resistant surface, PCA results showed clear differences between protein resistant and nonprotein-resistant surfaces. Therefore, ToF-SIMS results combined with PCA confirmed that the PLL-PMOXA adlayer with brush architecture resists protein adsorption. However, low increases of some amino acid signals in ToF-SIMS spectra were detected after the adlayer has been exposed to human serum.

  17. Distribution of coniferin in freeze-fixed stem of Ginkgo biloba L. by cryo-TOF-SIMS/SEM

    NASA Astrophysics Data System (ADS)

    Aoki, Dan; Hanaya, Yuto; Akita, Takuya; Matsushita, Yasuyuki; Yoshida, Masato; Kuroda, Katsushi; Yagami, Sachie; Takama, Ruka; Fukushima, Kazuhiko

    2016-08-01

    To clarify the role of coniferin in planta, semi-quantitative cellular distribution of coniferin in quick-frozen Ginkgo biloba L. (ginkgo) was visualized by cryo time-of-flight secondary ion mass spectrometry and scanning electron microscopy (cryo-TOF-SIMS/SEM) analysis. The amount and rough distribution of coniferin were confirmed through quantitative chromatography measurement using serial tangential sections of the freeze-fixed ginkgo stem. The lignification stage of the sample was estimated using microscopic observations. Coniferin distribution visualized at the transverse and radial surfaces of freeze-fixed ginkgo stem suggested that coniferin is stored in the vacuoles, and showed good agreement with the assimilation timing of coniferin to lignin in differentiating xylem. Consequently, it is suggested that coniferin is stored in the tracheid cells of differentiating xylem and is a lignin precursor.

  18. Protein quantification on dendrimer-activated surfaces by using time-of-flight secondary ion mass spectrometry and principal component regression

    NASA Astrophysics Data System (ADS)

    Kim, Young-Pil; Hong, Mi-Young; Shon, Hyun Kyong; Chegal, Won; Cho, Hyun Mo; Moon, Dae Won; Kim, Hak-Sung; Lee, Tae Geol

    2008-12-01

    Interaction between streptavidin and biotin on poly(amidoamine) (PAMAM) dendrimer-activated surfaces and on self-assembled monolayers (SAMs) was quantitatively studied by using time-of-flight secondary ion mass spectrometry (ToF-SIMS). The surface protein density was systematically varied as a function of protein concentration and independently quantified using the ellipsometry technique. Principal component analysis (PCA) and principal component regression (PCR) were used to identify a correlation between the intensities of the secondary ion peaks and the surface protein densities. From the ToF-SIMS and ellipsometry results, a good linear correlation of protein density was found. Our study shows that surface protein densities are higher on dendrimer-activated surfaces than on SAMs surfaces due to the spherical property of the dendrimer, and that these surface protein densities can be easily quantified with high sensitivity in a label-free manner by ToF-SIMS.

  19. Measurement of carbon distribution in nuclear fuel pin cladding specimens by means of a secondary ion mass spectrometer

    NASA Astrophysics Data System (ADS)

    Bart, Gerhard; Aerne, Ernst Tino; Burri, Martin; Zwicky, Hans-Urs

    1986-11-01

    Cladding carburization during irradiation of advanced mixed uranium plutonium carbide fast breeder reactor fuel is possibly a life limiting fuel pin factor. The quantitative assessment of such clad carbon embrittlement is difficult to perform by electron microprobe analysis because of sample surface contamination, and due to the very low energy of the carbon K α X-ray transition. The work presented here describes a method developed at the Swiss Federal Institute for Reactor Research (EIR) to use shielded secondary ion mass spectrometry (SIMS) as an accurate tool to determine radial distribution profiles of carbon in radioactive stainless steel fuel pin cladding. Compared with nuclear microprobe analysis (NMA) [1], which is also an accurate method for carbon analysis, the SIMS method distinguishes itself by its versatility for simultaneous determination of additional impurities.

  20. Useful ion yields for Cameca IMS 3f and 6f SIMS: Limits on quantitative analysis

    USGS Publications Warehouse

    Hervig, R.L.; Mazdab, F.K.; Williams, Pat; Guan, Y.; Huss, G.R.; Leshin, L.A.

    2006-01-01

    The useful yields (ions detected/atom sputtered) of major and trace elements in NIST 610 glass were measured by secondary ion mass spectrometry (SIMS) using Cameca IMS 3f and 6f instruments. Useful yields of positive ions at maximum transmission range from 10-4 to 0.2 and are negatively correlated with ionization potential. We quantified the decrease in useful yields when applying energy filtering or high mass resolution techniques to remove molecular interferences. The useful yields of selected negative ions (O, S, Au) in magnetite and pyrite were also determined. These data allow the analyst to determine if a particular analysis (trace element contents or isotopic ratio) can be achieved, given the amount of sample available and the conditions of the analysis. ?? 2005 Elsevier B.V. All rights reserved.

  1. Photo ion spectrometer

    DOEpatents

    Gruen, Dieter M.; Young, Charles E.; Pellin, Michael J.

    1989-01-01

    A charged particle spectrometer for performing ultrasensitive quantitative analysis of selected atomic components removed from a sample. Significant improvements in performing energy and angular refocusing spectroscopy are accomplished by means of a two dimensional structure for generating predetermined electromagnetic field boundary conditions. Both resonance and non-resonance ionization of selected neutral atomic components allow accumulation of increased chemical information. A multiplexed operation between a SIMS mode and a neutral atomic component ionization mode with EARTOF analysis enables comparison of chemical information from secondary ions and neutral atomic components removed from the sample. An electronic system is described for switching high level signals, such as SIMS signals, directly to a transient recorder and through a charge amplifier to the transient recorder for a low level signal pulse counting mode, such as for a neutral atomic component ionization mode.

  2. Evaluation of vSim for Nursing in an Adult Health Nursing Course: A Multisite Pilot Study.

    PubMed

    Wright, Renée R; Tinnon, Elizabeth A; Newton, Rebecca H

    2018-02-01

    Virtual simulation technology is the next step in using simulation as an accepted teaching-learning pedagogy in nursing. The purpose of this multisite, quasi-experimental, three-group, posttest-only design was to evaluate the effectiveness and participant satisfaction of vSim for Nursing in an Adult Health Nursing course. Although the quantitative findings (examination scores and postsimulation scores) were not statistically significant, participants overwhelmingly found vSim for Nursing to be a positive experiential learning endeavor. Ninety-one percent of the participants (n = 61) indicated that vSim for Nursing helped them understand adult health concepts and that vSim for Nursing was beneficial to learning. vSim for Nursing warrants further investigation, using other methods to measure effectiveness to ascertain whether knowledge acquisition is indeed improved as indicated by participant data in this study.

  3. Assessing resolution in live cell structured illumination microscopy

    NASA Astrophysics Data System (ADS)

    Pospíšil, Jakub; Fliegel, Karel; Klíma, Miloš

    2017-12-01

    Structured Illumination Microscopy (SIM) is a powerful super-resolution technique, which is able to enhance the resolution of optical microscope beyond the Abbe diffraction limit. In the last decade, numerous SIM methods that achieve the resolution of 100 nm in the lateral dimension have been developed. The SIM setups with new high-speed cameras and illumination pattern generators allow rapid acquisition of the live specimen. Therefore, SIM is widely used for investigation of the live structures in molecular and live cell biology. Quantitative evaluation of resolution enhancement in a real sample is essential to describe the efficiency of super-resolution microscopy technique. However, measuring the resolution of a live cell sample is a challenging task. Based on our experimental findings, the widely used Fourier ring correlation (FRC) method does not seem to be well suited for measuring the resolution of SIM live cell video sequences. Therefore, the resolution assessing methods based on Fourier spectrum analysis are often used. We introduce a measure based on circular average power spectral density (PSDca) estimated from a single SIM image (one video frame). PSDca describes the distribution of the power of a signal with respect to its spatial frequency. Spatial resolution corresponds to the cut-off frequency in Fourier space. In order to estimate the cut-off frequency from a noisy signal, we use a spectral subtraction method for noise suppression. In the future, this resolution assessment approach might prove useful also for single-molecule localization microscopy (SMLM) live cell imaging.

  4. X-ray microbeam three-dimensional topography for dislocation strain-field analysis of 4H-SiC

    NASA Astrophysics Data System (ADS)

    Tanuma, R.; Mori, D.; Kamata, I.; Tsuchida, H.

    2013-07-01

    This paper describes the strain-field analysis of threading edge dislocations (TEDs) and basal-plane dislocations (BPDs) in 4H-SiC using x-ray microbeam three-dimensional (3D) topography. This 3D topography enables quantitative strain-field analysis, which measures images of effective misorientations (Δω maps) around the dislocations. A deformation-matrix-based simulation algorithm is developed to theoretically evaluate the Δω mapping. Systematic linear calculations can provide simulated Δω maps (Δωsim maps) of dislocations with different Burgers vectors, directions, and reflection vectors for the desired cross-sections. For TEDs and BPDs, Δω maps are compared with Δωsim maps, and their excellent correlation is demonstrated. Two types of asymmetric reflections, high- and low-angle incidence types, are compared. Strain analyses are also conducted to investigate BPD-TED conversion near an epilayer/substrate interface in 4H-SiC.

  5. Imaging of arsenic traces in human hair by nano-SIMS 50

    NASA Astrophysics Data System (ADS)

    Audinot, J.-N.; Schneider, S.; Yegles, M.; Hallegot, P.; Wennig, R.; Migeon, H.-N.

    2004-06-01

    The nano-SIMS 50 allows ion imaging to be performed on microtomed hair cross-sections in order to determine the concentration and to localize the distribution of arsenic traces in hairs. Our study shows a linear relationship between the SIMS signal (As normalized with respect to CN) and the concentration determined by other analytical techniques. The advantages of SIMS imaging can be clearly proved by the capability to record quantitative distributions of As in the cross section. As a matter of fact, the nano-SIMS 50 images may allow differentiation between As located in the medulla, the cortex and the cuticle of the hair and thus distinguish between intoxication by indigestion and surface pollution of the sample.

  6. Photo ion spectrometer

    DOEpatents

    Gruen, D.M.; Young, C.E.; Pellin, M.J.

    1989-12-26

    A charged particle spectrometer is described for performing ultrasensitive quantitative analysis of selected atomic components removed from a sample. Significant improvements in performing energy and angular refocusing spectroscopy are accomplished by means of a two dimensional structure for generating predetermined electromagnetic field boundary conditions. Both resonance and non-resonance ionization of selected neutral atomic components allow accumulation of increased chemical information. A multiplexed operation between a SIMS mode and a neutral atomic component ionization mode with EARTOF analysis enables comparison of chemical information from secondary ions and neutral atomic components removed from the sample. An electronic system is described for switching high level signals, such as SIMS signals, directly to a transient recorder and through a charge amplifier to the transient recorder for a low level signal pulse counting mode, such as for a neutral atomic component ionization mode. 12 figs.

  7. Detection of Matrix Elements and Trace Impurities in Cu(In, Ga)Se2 Photovoltaic Absorbers Using Surface Analytical Techniques.

    PubMed

    Kim, Min Jung; Lee, Jihye; Kim, Seon Hee; Kim, Haidong; Lee, Kang-Bong; Lee, Yeonhee

    2015-10-01

    Chalcopyrite Cu(In, Ga)Se2 (CIGS) thin films are well known as the next-generation solar cell materials notable for their high absorption coefficient for solar radiation, suitable band gap, and ability for deposition on flexible substrate materials, allowing the production of highly flexible and lightweight solar panels. To improve solar cell performances, a quantitative and depth-resolved elemental analysis of photovoltaic thin films is much needed. In this study, Cu(In, Ga)Se2 thin films were prepared on molybdenum back contacts deposited on soda-lime glass substrates via three-stage evaporation. Surface analyses via AES and SIMS were used to characterize the CIGS thin films and compare their depth profiles. We determined the average concentration of the matrix elements, Cu, In, Ga, and Se, using ICP-AES, XRF, and EPMA. We also obtained depth profiling results using TOF-SIMS, magnetic sector SIMS and AES, and APT, a sub-nanometer resolution characterization technique that enables three-dimensional elemental mapping. The SIMS technique, with its high detection limit and ability to obtain the profiles of elements in parallel, is a powerful tool for monitoring trace elements in CIGS thin films. To identify impurities in a CIGS layer, the distribution of trace elements was also observed according to depth by SIMS and APT.

  8. Development of nanotopography during SIMS characterization of thin films of Ge1-xSnx alloy

    NASA Astrophysics Data System (ADS)

    Secchi, M.; Demenev, E.; Colaux, J. L.; Giubertoni, D.; Dell'Anna, R.; Iacob, E.; Gwilliam, R. M.; Jeynes, C.; Bersani, M.

    2015-11-01

    This work presents a study of application of secondary ion mass spectrometry (SIMS) to measure tin concentration in Ge1-xSnx alloy with x higher than solid solubility ∼1%, i.e. well above the diluted regime where SIMS measurements usually provide the most reliable quantitative results. SIMS analysis was performed on Sn+ ion implanted Ge films, epitaxially deposited on Si, and on chemical vapor deposition deposited Ge0.93Sn0.07 alloy. Three SIMS conditions were investigated, varying primary beam ion species and secondary ion polarity keeping 1 keV impact energy. Best depth profile accuracy, best agreement with the fluences measured by Rutherford backscattering spectrometry, good detection limit (∼1 × 1017 at/cm3) and depth resolution (∼2 nm/decade) are achieved in Cs+/SnCs+ configuration. However, applied sputtering conditions (Cs+ 1 keV, 64° incidence vs. normal) induced an early formation of surface topography on the crater bottom resulting in significant variation of sputtering yield. Atomic force microscopy shows a peculiar topography developed on Ge: for oblique incidence, a topography consisting in a sequence of dots and ripples was observed on the crater bottom. This behavior is unusual for grazing incidence and has been observed to increase with the Cs+ fluence. Rotating sample during sputtering prevents this ripple formation and consequently improves the depth accuracy.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Renslow, Ryan S.; Lindemann, Stephen R.; Cole, Jessica K.

    EElucidating nutrient exchange in microbial communities is an important step in understanding the relationships between microbial systems and global biogeochemical cycles, but these communities are complex and the interspecies interactions that occur within them are not well understood. Phototrophic consortia are useful and relevant experimental systems to investigate such interactions as they are not only prevalent in the environment, but some are cultivable in vivo and amenable to controlled scientific experimentation. High spatial resolution secondary ion mass spectrometry (NanoSIMS) is a powerful tool capable of visualizing the metabolic activities of single cells within a biofilm, but quantitative analysis of themore » resulting data has typically been a manual process, resulting in a task that is both laborious and susceptible to human error. Here, we describe the creation and application of a semi-automated image-processing pipeline that can analyze NanoSIMS-generated data of phototrophic biofilms. The tool employs an image analysis process, which includes both elemental and morphological segmentation, producing a final segmented image that allows for discrimination between autotrophic and heterotrophic biomass, the detection of individual cyanobacterial filaments and heterotrophic cells, the quantification of isotopic incorporation of individual heterotrophic cells, and calculation of relevant population statistics. We demonstrate the functionality of the tool by using it to analyze the uptake of 15N provided as either nitrate or ammonium through the unicyanobacterial consortium UCC-O and imaged via NanoSIMS. We found that the degree of 15N incorporation by individual cells was highly variable when labeled with 15NH4 +, but much more even when biofilms were labeled with 15NO3-. In the 15NH4 +-amended biofilms, the heterotrophic distribution of 15N incorporation was highly skewed, with a large population showing moderate 15N incorporation and a small number of organisms displaying very high 15N uptake. The results showed that analysis of NanoSIMS data can be performed in a way that allows for quantitation of the elemental uptake of individual cells, a technique necessary for advancing research into the metabolic networks that exist within biofilms with statistical analyses that are supported by automated, user-friendly processes.« less

  10. Evaluation of blood adsorption onto dialysis membranes by time-of-flight secondary ion mass spectrometry and near-field infrared microscopy.

    PubMed

    Aoyagi, Satoka; Abe, Kiyoshi; Yamagishi, Takayuki; Iwai, Hideo; Yamaguchi, Satoru; Sunohara, Takashi

    2017-11-01

    Blood adsorption onto the inside surface of hollow fiber dialysis membranes was investigated by means of time-of-flight secondary ion mass spectrometry (TOF-SIMS) and near-field infrared microscopy (NFIR) in order to evaluate the biocompatibility and permeability of dialysis membranes. TOF-SIMS is useful for the imaging of particular molecules with a high spatial resolution of approximately 100 nm. In contrast, infrared spectra provide quantitative information and NFIR enables analysis with a high spatial resolution of less than 1 μm, which is close to the resolution of TOF-SIMS. A comparison was made of one of the most widely used dialysis membranes made of polysulfone (PSf), that has an asymmetric and inhomogeneous pore structure, and a newly developed asymmetric cellulose triacetate (ATA) membrane that also has an asymmetric pore structure, even though the conventional cellulose triacetate membrane has a symmetric and homogeneous pore structure. As a result, it was demonstrated that blood adsorption on the inside surface of the ATA membrane is more reduced than that on the PSf membrane. Graphical abstract Analysis of blood adsorption on inside surface of hollow fiber membrane.

  11. Benchmarking Exercises To Validate The Updated ELLWF GoldSim Slit Trench Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, G. A.; Hiergesell, R. A.

    2013-11-12

    The Savannah River National Laboratory (SRNL) results of the 2008 Performance Assessment (PA) (WSRC, 2008) sensitivity/uncertainty analyses conducted for the trenches located in the EArea LowLevel Waste Facility (ELLWF) were subject to review by the United States Department of Energy (U.S. DOE) Low-Level Waste Disposal Facility Federal Review Group (LFRG) (LFRG, 2008). LFRG comments were generally approving of the use of probabilistic modeling in GoldSim to support the quantitative sensitivity analysis. A recommendation was made, however, that the probabilistic models be revised and updated to bolster their defensibility. SRS committed to addressing those comments and, in response, contracted with Neptunemore » and Company to rewrite the three GoldSim models. The initial portion of this work, development of Slit Trench (ST), Engineered Trench (ET) and Components-in-Grout (CIG) trench GoldSim models, has been completed. The work described in this report utilizes these revised models to test and evaluate the results against the 2008 PORFLOW model results. This was accomplished by first performing a rigorous code-to-code comparison of the PORFLOW and GoldSim codes and then performing a deterministic comparison of the two-dimensional (2D) unsaturated zone and three-dimensional (3D) saturated zone PORFLOW Slit Trench models against results from the one-dimensional (1D) GoldSim Slit Trench model. The results of the code-to-code comparison indicate that when the mechanisms of radioactive decay, partitioning of contaminants between solid and fluid, implementation of specific boundary conditions and the imposition of solubility controls were all tested using identical flow fields, that GoldSim and PORFLOW produce nearly identical results. It is also noted that GoldSim has an advantage over PORFLOW in that it simulates all radionuclides simultaneously - thus avoiding a potential problem as demonstrated in the Case Study (see Section 2.6). Hence, it was concluded that the follow-on work using GoldSim to develop 1D equivalent models of the PORFLOW multi-dimensional models was justified. The comparison of GoldSim 1D equivalent models to PORFLOW multi-dimensional models was made at two locations in the model domains - at the unsaturated-saturated zone interface and at the 100m point of compliance. PORFLOW model results from the 2008 PA were utilized to investigate the comparison. By making iterative adjustments to certain water flux terms in the GoldSim models it was possible to produce contaminant mass fluxes and water concentrations that were highly similar to the PORFLOW model results at the two locations where comparisons were made. Based on the ability of the GoldSim 1D trench models to produce mass flux and concentration curves that are sufficiently similar to multi-dimensional PORFLOW models for all of the evaluated radionuclides and their progeny, it is concluded that the use of the GoldSim 1D equivalent Slit and Engineered trenches models for further probabilistic sensitivity and uncertainty analysis of ELLWF trench units is justified. A revision to the original report was undertaken to correct mislabeling on the y-axes of the compliance point concentration graphs, to modify the terminology used to define the ''blended'' source term Case for the saturated zone to make it consistent with terminology used in the 2008 PA, and to make a more definitive statement regarding the justification of the use of the GoldSim 1D equivalent trench models for follow-on probabilistic sensitivity and uncertainty analysis.« less

  12. Detection and distribution of lithium in Mg-Li-Al based alloy by ToF-SIMS

    NASA Astrophysics Data System (ADS)

    Kumar, Vinod

    2016-12-01

    Time of Flight-Secondary Ion Mass Spectrometry (ToF-SIMS) is used to investigate the surface as well as bulk microstructural features of novel Mg-Li-Al based alloy namely Mg-9Li-7Al-3Sn-1Zn (LATZ9531). ToF-SIMS study indicates that there are six multi-oxide layers present within the surface film of LATZ9531. Furthermore, The presence of Li containing phase has been qualitatively confirmed based on the high number of Li-ion counts in SIMS, and the same is verified quantitatively by using electron probe microanalysis (EPMA). The novel approach may be useful to determine the chemical composition of the phases in various alloys which has lighter alloying elements such as lithium.

  13. Topochemical Analysis of Cell Wall Components by TOF-SIMS.

    PubMed

    Aoki, Dan; Fukushima, Kazuhiko

    2017-01-01

    Time-of-flight secondary ion mass spectrometry (TOF-SIMS) is a recently developing analytical tool and a type of imaging mass spectrometry. TOF-SIMS provides mass spectral information with a lateral resolution on the order of submicrons, with widespread applicability. Sometimes, it is described as a surface analysis method without the requirement for sample pretreatment; however, several points need to be taken into account for the complete utilization of the capabilities of TOF-SIMS. In this chapter, we introduce methods for TOF-SIMS sample treatments, as well as basic knowledge of wood samples TOF-SIMS spectral and image data analysis.

  14. Development and application of a Chinese webpage suicide information mining system (sims).

    PubMed

    Chen, Penglai; Chai, Jing; Zhang, Lu; Wang, Debin

    2014-11-01

    This study aims at designing and piloting a convenient Chinese webpage suicide information mining system (SIMS) to help search and filter required data from the internet and discover potential features and trends of suicide. SIMS utilizes Microsoft Visual Studio2008, SQL2008 and C# as development tools. It collects webpage data via popular search engines; cleans the data using trained models plus minimum manual help; translates the cleaned texts into quantitative data through models and supervised fuzzy recognition; analyzes and visualizes related variables by self-programmed algorithms. The SIMS developed comprises such functions as suicide news and blogs collection, data filtering, cleaning, extraction and translation, data analysis and presentation. SIMS-mediated mining of one-year webpage revealed that: peak months and hours of web-reported suicide events were June-July and 10-11 am respectively, and the lowest months and hours, September-October and 1-7 am; suicide reports came mostly from Soho, Tecent, Sina etc.; male suicide victims over counted female victims in most sub-regions but southwest China; homes, public places and rented houses were the top three places to commit suicide; poisoning, cutting vein and jumping from building were the most commonly used methods to commit suicide; love disputes, family disputes and mental diseases were the leading causes. SIMS provides a preliminary and supplementary means for monitoring and understanding suicide. It proposes useful aspects as well as tools for analyzing the features and trends of suicide using data derived from Chinese webpages. Yet given the intrinsic "dual nature" of internet-based suicide information and the tremendous difficulties experienced by ourselves and other researchers, there is still a long way to go for us to expand, refine and evaluate the system.

  15. Multi-dimensional TOF-SIMS analysis for effective profiling of disease-related ions from the tissue surface.

    PubMed

    Park, Ji-Won; Jeong, Hyobin; Kang, Byeongsoo; Kim, Su Jin; Park, Sang Yoon; Kang, Sokbom; Kim, Hark Kyun; Choi, Joon Sig; Hwang, Daehee; Lee, Tae Geol

    2015-06-05

    Time-of-flight secondary ion mass spectrometry (TOF-SIMS) emerges as a promising tool to identify the ions (small molecules) indicative of disease states from the surface of patient tissues. In TOF-SIMS analysis, an enhanced ionization of surface molecules is critical to increase the number of detected ions. Several methods have been developed to enhance ionization capability. However, how these methods improve identification of disease-related ions has not been systematically explored. Here, we present a multi-dimensional SIMS (MD-SIMS) that combines conventional TOF-SIMS and metal-assisted SIMS (MetA-SIMS). Using this approach, we analyzed cancer and adjacent normal tissues first by TOF-SIMS and subsequently by MetA-SIMS. In total, TOF- and MetA-SIMS detected 632 and 959 ions, respectively. Among them, 426 were commonly detected by both methods, while 206 and 533 were detected uniquely by TOF- and MetA-SIMS, respectively. Of the 426 commonly detected ions, 250 increased in their intensities by MetA-SIMS, whereas 176 decreased. The integrated analysis of the ions detected by the two methods resulted in an increased number of discriminatory ions leading to an enhanced separation between cancer and normal tissues. Therefore, the results show that MD-SIMS can be a useful approach to provide a comprehensive list of discriminatory ions indicative of disease states.

  16. Multi-dimensional TOF-SIMS analysis for effective profiling of disease-related ions from the tissue surface

    PubMed Central

    Park, Ji-Won; Jeong, Hyobin; Kang, Byeongsoo; Kim, Su Jin; Park, Sang Yoon; Kang, Sokbom; Kim, Hark Kyun; Choi, Joon Sig; Hwang, Daehee; Lee, Tae Geol

    2015-01-01

    Time-of-flight secondary ion mass spectrometry (TOF-SIMS) emerges as a promising tool to identify the ions (small molecules) indicative of disease states from the surface of patient tissues. In TOF-SIMS analysis, an enhanced ionization of surface molecules is critical to increase the number of detected ions. Several methods have been developed to enhance ionization capability. However, how these methods improve identification of disease-related ions has not been systematically explored. Here, we present a multi-dimensional SIMS (MD-SIMS) that combines conventional TOF-SIMS and metal-assisted SIMS (MetA-SIMS). Using this approach, we analyzed cancer and adjacent normal tissues first by TOF-SIMS and subsequently by MetA-SIMS. In total, TOF- and MetA-SIMS detected 632 and 959 ions, respectively. Among them, 426 were commonly detected by both methods, while 206 and 533 were detected uniquely by TOF- and MetA-SIMS, respectively. Of the 426 commonly detected ions, 250 increased in their intensities by MetA-SIMS, whereas 176 decreased. The integrated analysis of the ions detected by the two methods resulted in an increased number of discriminatory ions leading to an enhanced separation between cancer and normal tissues. Therefore, the results show that MD-SIMS can be a useful approach to provide a comprehensive list of discriminatory ions indicative of disease states. PMID:26046669

  17. FluoroSim: A Visual Problem-Solving Environment for Fluorescence Microscopy

    PubMed Central

    Quammen, Cory W.; Richardson, Alvin C.; Haase, Julian; Harrison, Benjamin D.; Taylor, Russell M.; Bloom, Kerry S.

    2010-01-01

    Fluorescence microscopy provides a powerful method for localization of structures in biological specimens. However, aspects of the image formation process such as noise and blur from the microscope's point-spread function combine to produce an unintuitive image transformation on the true structure of the fluorescing molecules in the specimen, hindering qualitative and quantitative analysis of even simple structures in unprocessed images. We introduce FluoroSim, an interactive fluorescence microscope simulator that can be used to train scientists who use fluorescence microscopy to understand the artifacts that arise from the image formation process, to determine the appropriateness of fluorescence microscopy as an imaging modality in an experiment, and to test and refine hypotheses of model specimens by comparing the output of the simulator to experimental data. FluoroSim renders synthetic fluorescence images from arbitrary geometric models represented as triangle meshes. We describe three rendering algorithms on graphics processing units for computing the convolution of the specimen model with a microscope's point-spread function and report on their performance. We also discuss several cases where the microscope simulator has been used to solve real problems in biology. PMID:20431698

  18. Phase contrast imaging X-ray computed tomography: quantitative characterization of human patellar cartilage matrix with topological and geometrical features

    NASA Astrophysics Data System (ADS)

    Nagarajan, Mahesh B.; Coan, Paola; Huber, Markus B.; Diemoz, Paul C.; Wismüller, Axel

    2014-03-01

    Current assessment of cartilage is primarily based on identification of indirect markers such as joint space narrowing and increased subchondral bone density on x-ray images. In this context, phase contrast CT imaging (PCI-CT) has recently emerged as a novel imaging technique that allows a direct examination of chondrocyte patterns and their correlation to osteoarthritis through visualization of cartilage soft tissue. This study investigates the use of topological and geometrical approaches for characterizing chondrocyte patterns in the radial zone of the knee cartilage matrix in the presence and absence of osteoarthritic damage. For this purpose, topological features derived from Minkowski Functionals and geometric features derived from the Scaling Index Method (SIM) were extracted from 842 regions of interest (ROI) annotated on PCI-CT images of healthy and osteoarthritic specimens of human patellar cartilage. The extracted features were then used in a machine learning task involving support vector regression to classify ROIs as healthy or osteoarthritic. Classification performance was evaluated using the area under the receiver operating characteristic (ROC) curve (AUC). The best classification performance was observed with high-dimensional geometrical feature vectors derived from SIM (0.95 ± 0.06) which outperformed all Minkowski Functionals (p < 0.001). These results suggest that such quantitative analysis of chondrocyte patterns in human patellar cartilage matrix involving SIM-derived geometrical features can distinguish between healthy and osteoarthritic tissue with high accuracy.

  19. Sample processing, protocol, and statistical analysis of the time-of-flight secondary ion mass spectrometry (ToF-SIMS) of protein, cell, and tissue samples.

    PubMed

    Barreto, Goncalo; Soininen, Antti; Sillat, Tarvo; Konttinen, Yrjö T; Kaivosoja, Emilia

    2014-01-01

    Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is increasingly being used in analysis of biological samples. For example, it has been applied to distinguish healthy and osteoarthritic human cartilage. This chapter discusses ToF-SIMS principle and instrumentation including the three modes of analysis in ToF-SIMS. ToF-SIMS sets certain requirements for the samples to be analyzed; for example, the samples have to be vacuum compatible. Accordingly, sample processing steps for different biological samples, i.e., proteins, cells, frozen and paraffin-embedded tissues and extracellular matrix for the ToF-SIMS are presented. Multivariate analysis of the ToF-SIMS data and the necessary data preprocessing steps (peak selection, data normalization, mean-centering, and scaling and transformation) are discussed in this chapter.

  20. Quantitative trait loci for maysin synthesis in maize (Zea mays L.) lines selected for high silk maysin content.

    PubMed

    Meyer, J D F; Snook, M E; Houchins, K E; Rector, B G; Widstrom, N W; McMullen, M D

    2007-06-01

    Maysin is a naturally occurring C-glycosyl flavone found in maize (Zea mays L.) silk tissue that confers resistance to corn earworm (Helicoverpa zea, Boddie). Recently, two new maize populations were derived for high silk maysin. The two populations were named the exotic populations of maize (EPM) and the southern inbreds of maize (SIM). Quantitative trait locus (QTL) analysis was employed to determine which loci were responsible for elevated maysin levels in inbred lines derived from the EPM and SIM populations. The candidate genes consistent with QTL position included the p (pericarp color), c2 (colorless2), whp1 (white pollen1) and in1 (intensifier1) loci. The role of these loci in controlling high maysin levels in silks was tested by expression analysis and use of the loci as genetic markers onto the QTL populations. These studies support p, c2 and whp1, but not in1, as loci controlling maysin. Through this study, we determined that the p locus regulates whp1 transcription and that increased maysin in these inbred lines was primarily due to alleles at both structural and regulatory loci promoting increased flux through the flavone pathway by increasing chalcone synthase activity.

  1. Reducing the Matrix Effect in Organic Cluster SIMS Using Dynamic Reactive Ionization

    NASA Astrophysics Data System (ADS)

    Tian, Hua; Wucher, Andreas; Winograd, Nicholas

    2016-12-01

    Dynamic reactive ionization (DRI) utilizes a reactive molecule, HCl, which is doped into an Ar cluster projectile and activated to produce protons at the bombardment site on the cold sample surface with the presence of water. The methodology has been shown to enhance the ionization of protonated molecular ions and to reduce salt suppression in complex biomatrices. In this study, we further examine the possibility of obtaining improved quantitation with DRI during depth profiling of thin films. Using a trehalose film as a model system, we are able to define optimal DRI conditions for depth profiling. Next, the strategy is applied to a multilayer system consisting of the polymer antioxidants Irganox 1098 and 1010. These binary mixtures have demonstrated large matrix effects, making quantitative SIMS measurement not feasible. Systematic comparisons of depth profiling of this multilayer film between directly using GCIB, and under DRI conditions, show that the latter enhances protonated ions for both components by 4- to 15-fold, resulting in uniform depth profiling in positive ion mode and almost no matrix effect in negative ion mode. The methodology offers a new strategy to tackle the matrix effect and should lead to improved quantitative measurement using SIMS.

  2. CCQM Pilot Study CCQM-P140: Quantitative surface analysis of multi-element alloy films

    NASA Astrophysics Data System (ADS)

    Kim, Kyung Joong; Jang, Jong Shik; Kim, An Soon; Suh, Jung Ki; Chung, Yong-Duck; Hodoroaba, Vasile-Dan; Wirth, Thomas; Unger, Wolfgang; Kang, Hee Jae; Popov, Oleg; Popov, Inna; Kuselman, Ilya; Lee, Yeon Hee; Sykes, David E.; Wang, Meiling; Wang, Hai; Ogiwara, Toshiya; Nishio, Mitsuaki; Tanuma, Shigeo; Simons, David; Szakal, Christopher; Osborn, William; Terauchi, Shinya; Ito, Mika; Kurokawa, Akira; Fujimoto, Toshiyuki; Jordaan, Werner; Jeong, Chil Seong; Havelund, Rasmus; Spencer, Steve; Shard, Alex; Streeck, Cornelia; Beckhoff, Burkhard; Eicke, Axel; Terborg, Ralf

    2015-01-01

    A pilot study for a quantitative surface analysis of multi-element alloy films has been performed by the Surface Analysis Working Group (SAWG) of the Consultative Committee for Amount of Substance (CCQM). The aim of this pilot study is to evaluate a protocol for a key comparison to demonstrate the equivalence of measures by National Metrology Institutes (NMIs) and Designated Institutes (DI) for the mole fractions of multi-element alloy films. A Cu(In,Ga)Se2 (CIGS) film with non-uniform depth distribution was chosen as a representative multi-element alloy film. The mole fractions of the reference and the test CIGS films were certified by isotope dilution—inductively coupled plasma/mass spectrometry. A total number counting (TNC) method was used as a method to determine the signal intensities of the constituent elements acquired in SIMS, XPS and AES depth profiling. TNC method is comparable with the certification process because the certified mole fractions are the average values of the films. The mole fractions of the CIGS films were measured by Secondary Ion Mass Spectrometry (SIMS), Auger Electron Spectroscopy (AES), X-ray Photoelectron Spectroscopy (XPS), X-Ray Fluorescence (XRF) Analysis and Electron Probe Micro Analysis (EPMA) with Energy Dispersive X-ray Spectrometry (EDX). Fifteen laboratories from eight NMIs, one DI, and six non-NMIs participated in this pilot study. The average mole fractions of the reported data showed relative standard deviations from 5.5 % to 6.8 % and average relative expanded uncertainties in the range from 4.52 % to 4.86 % for the four test CIGS specimens. These values are smaller than those in the key comparison CCQM-K67 for the measurement of mole fractions of Fe-Ni alloy films. As one result it can be stated that SIMS, XPS and AES protocols relying on the quantification of CIGS films using the TNC method are mature to be used in a CCQM key comparison. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by CCQM.

  3. Rapid characterisation of surface modifications and treatments using a benchtop SIMS instrument

    NASA Astrophysics Data System (ADS)

    McPhail, D. S.; Sokhan, M.; Rees, E. E.; Cliff, B.; Eccles, A. J.; Chater, R. J.

    2004-06-01

    The development of a novel benchtop SIMS instrument (Millbrook MiniSIMS) [Appl. Surf. Sci. 144 (1999) 106] has brought routine SIMS analysis to many new users, for example museum conservators. This is a result of the simple operation and the relatively low capital cost of the instrument. We report here on the continued development of the system in terms of increasing performance and functionality and its use in museum conservation based applications where a mobile instrument for high throughput, rapid SIMS analysis has proven to be of great benefit to the user. The example we describe here is the application of the MiniSIMS to the analysis of silver thread woven into a silk dress before and after laser cleaning.

  4. Artificial Intelligence (Al) Center of Excellence at the University of Pennsylvania

    DTIC Science & Technology

    1995-07-01

    Approach and repel behaviors were implemented in order to study higher level behavioral simulation . Parallel algorithms for motion planning (as a...of decision-making accuracy can be specified for this graph-reduction process. We have also developed a mixed qualitative/quantitative simulation ...system, called QobiSIM. QobiSIM has been used to develop a cardiovascular simulation to be incorporated into the TraumAID system. This cardiovascular

  5. RxnSim: a tool to compare biochemical reactions.

    PubMed

    Giri, Varun; Sivakumar, Tadi Venkata; Cho, Kwang Myung; Kim, Tae Yong; Bhaduri, Anirban

    2015-11-15

    : Quantitative assessment of chemical reaction similarity aids database searches, classification of reactions and identification of candidate enzymes. Most methods evaluate reaction similarity based on chemical transformation patterns. We describe a tool, RxnSim, which computes reaction similarity based on the molecular signatures of participating molecules. The tool is able to compare reactions based on similarities of substrates and products in addition to their transformation. It allows masking of user-defined chemical moieties for weighted similarity computations. RxnSim is implemented in R and is freely available from the Comprehensive R Archive Network, CRAN (http://cran.r-project.org/web/packages/RxnSim/). anirban.b@samsung.com or ty76.kim@samsung.com Supplementary data are available at Bioinformatics online. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  6. Highly hydrogen-sensitive thermal desorption spectroscopy system for quantitative analysis of low hydrogen concentration (˜1 × 1016 atoms/cm3) in thin-film samples

    NASA Astrophysics Data System (ADS)

    Hanna, Taku; Hiramatsu, Hidenori; Sakaguchi, Isao; Hosono, Hideo

    2017-05-01

    We developed a highly hydrogen-sensitive thermal desorption spectroscopy (HHS-TDS) system to detect and quantitatively analyze low hydrogen concentrations in thin films. The system was connected to an in situ sample-transfer chamber system, manipulators, and an rf magnetron sputtering thin-film deposition chamber under an ultra-high-vacuum (UHV) atmosphere of ˜10-8 Pa. The following key requirements were proposed in developing the HHS-TDS: (i) a low hydrogen residual partial pressure, (ii) a low hydrogen exhaust velocity, and (iii) minimization of hydrogen thermal desorption except from the bulk region of the thin films. To satisfy these requirements, appropriate materials and components were selected, and the system was constructed to extract the maximum performance from each component. Consequently, ˜2000 times higher sensitivity to hydrogen than that of a commercially available UHV-TDS system was achieved using H+-implanted Si samples. Quantitative analysis of an amorphous oxide semiconductor InGaZnO4 thin film (1 cm × 1 cm × 1 μm thickness, hydrogen concentration of 4.5 × 1017 atoms/cm3) was demonstrated using the HHS-TDS system. This concentration level cannot be detected using UHV-TDS or secondary ion mass spectroscopy (SIMS) systems. The hydrogen detection limit of the HHS-TDS system was estimated to be ˜1 × 1016 atoms/cm3, which implies ˜2 orders of magnitude higher sensitivity than that of SIMS and resonance nuclear reaction systems (˜1018 atoms/cm3).

  7. TOF-SIMS Analysis of Red Color Inks of Writing and Printing Tools on Questioned Documents.

    PubMed

    Lee, Jihye; Nam, Yun Sik; Min, Jisook; Lee, Kang-Bong; Lee, Yeonhee

    2016-05-01

    Time-of-flight secondary ion mass spectrometry (TOF-SIMS) is a well-established surface technique that provides both elemental and molecular information from several monolayers of a sample surface while also allowing depth profiling or image mapping to be performed. Static TOF-SIMS with improved performances has expanded the application of TOF-SIMS to the study of a variety of organic, polymeric, biological, archaeological, and forensic materials. In forensic investigation, the use of a minimal sample for the analysis is preferable. Although the TOF-SIMS technique is destructive, the probing beams have microsized diameters so that only small portion of the questioned sample is necessary for the analysis, leaving the rest available for other analyses. In this study, TOF-SIMS and attenuated total reflectance Fourier transform infrared (ATR-FTIR) were applied to the analysis of several different pen inks, red sealing inks, and printed patterns on paper. The overlapping areas of ballpoint pen writing, red seal stamping, and laser printing in a document were investigated to identify the sequence of recording. The sequence relations for various cases were determined from the TOF-SIMS mapping image and the depth profile. TOF-SIMS images were also used to investigate numbers or characters altered with two different red pens. TOF-SIMS was successfully used to determine the sequence of intersecting lines and the forged numbers on the paper. © 2016 American Academy of Forensic Sciences.

  8. TOF-SIMS imaging technique with information entropy

    NASA Astrophysics Data System (ADS)

    Aoyagi, Satoka; Kawashima, Y.; Kudo, Masahiro

    2005-05-01

    Time-of-flight secondary ion mass spectrometry (TOF-SIMS) is capable of chemical imaging of proteins on insulated samples in principal. However, selection of specific peaks related to a particular protein, which are necessary for chemical imaging, out of numerous candidates had been difficult without an appropriate spectrum analysis technique. Therefore multivariate analysis techniques, such as principal component analysis (PCA), and analysis with mutual information defined by information theory, have been applied to interpret SIMS spectra of protein samples. In this study mutual information was applied to select specific peaks related to proteins in order to obtain chemical images. Proteins on insulated materials were measured with TOF-SIMS and then SIMS spectra were analyzed by means of the analysis method based on the comparison using mutual information. Chemical mapping of each protein was obtained using specific peaks related to each protein selected based on values of mutual information. The results of TOF-SIMS images of proteins on the materials provide some useful information on properties of protein adsorption, optimality of immobilization processes and reaction between proteins. Thus chemical images of proteins by TOF-SIMS contribute to understand interactions between material surfaces and proteins and to develop sophisticated biomaterials.

  9. The 3D-based scaling index algorithm to optimize structure analysis of trabecular bone in postmenopausal women with and without osteoporotic spine fractures

    NASA Astrophysics Data System (ADS)

    Muller, Dirk; Monetti, Roberto A.; Bohm, Holger F.; Bauer, Jan; Rummeny, Ernst J.; Link, Thomas M.; Rath, Christoph W.

    2004-05-01

    The scaling index method (SIM) is a recently proposed non-linear technique to extract texture measures for the quantitative characterisation of the trabecular bone structure in high resolution magnetic resonance imaging (HR-MRI). The three-dimensional tomographic images are interpreted as a point distribution in a state space where each point (voxel) is defined by its x, y, z coordinates and the grey value. The SIM estimates local scaling properties to describe the nonlinear morphological features in this four-dimensional point distribution. Thus, it can be used for differentiating between cluster-, rod-, sheet-like and unstructured (background) image components, which makes it suitable for quantifying the microstructure of human cancellous bone. The SIM was applied to high resolution magnetic resonance images of the distal radius in patients with and without osteoporotic spine fractures in order to quantify the deterioration of bone structure. Using the receiver operator characteristic (ROC) analysis the diagnostic performance of this texture measure in differentiating patients with and without fractures was compared with bone mineral density (BMD). The SIM demonstrated the best area under the curve (AUC) value for discriminating the two groups. The reliability of our new texture measure and the validity of our results were assessed by applying bootstrapping resampling methods. The results of this study show that trabecular structure measures derived from HR-MRI of the radius in a clinical setting using a recently proposed algorithm based on a local 3D scaling index method can significantly improve the diagnostic performance in differentiating postmenopausal women with and without osteoporotic spine fractures.

  10. LavaSIM: the effect of heat transfer in 3D on lava flow characteristics (Invited)

    NASA Astrophysics Data System (ADS)

    Fujita, E.

    2013-12-01

    Characteristics of lava flow are governed by many parameters like lava viscosity, effusion rate, ground topography, etc. The accuracy and applicability of lava flow simulation code is evaluated whether the numerical simulation can reproduce these features quantitatively, which is important from both strategic and scientific points of views. Many lava flow simulation codes are so far proposed, and they are classified into two categories, i.e., the deterministic and the probabilistic models. LavaSIM is one of the former category models, and has a disadvantage of time consuming. But LavaSIM can solves the equations of continuity, motion, energy by step and has an advantage in the calculation of three-dimensional analysis with solid-liquid two phase flow, including the heat transfer between lava, solidified crust, air, water and ground, and three-dimensional convection in liquid lava. In other word, we can check the detailed structure of lava flow by LavaSIM. Therefore, this code can produce both channeled and fan-dispersive flows. The margin of the flow is solidified by cooling and these solidified crusts control the behavior of successive lava flow. In case of a channel flow, the solidified margin supports the stable central main flow and elongates the lava flow distance. The cross section of lava flow shows that the liquid lava flows between solidified crusts. As for the lava extrusion flow rate, LavaSIM can include the time function as well as the location of the vents. In some cases, some parts of the solidified wall may be broken by the pressure of successive flow and/or re-melting. These mechanisms could characterize complex features of the observed lava flows at many volcanoes in the world. To apply LavaSIM to the benchmark tests organized by V-hub is important to improve the lava flow evaluation technique.

  11. SimHap GUI: an intuitive graphical user interface for genetic association analysis.

    PubMed

    Carter, Kim W; McCaskie, Pamela A; Palmer, Lyle J

    2008-12-25

    Researchers wishing to conduct genetic association analysis involving single nucleotide polymorphisms (SNPs) or haplotypes are often confronted with the lack of user-friendly graphical analysis tools, requiring sophisticated statistical and informatics expertise to perform relatively straightforward tasks. Tools, such as the SimHap package for the R statistics language, provide the necessary statistical operations to conduct sophisticated genetic analysis, but lacks a graphical user interface that allows anyone but a professional statistician to effectively utilise the tool. We have developed SimHap GUI, a cross-platform integrated graphical analysis tool for conducting epidemiological, single SNP and haplotype-based association analysis. SimHap GUI features a novel workflow interface that guides the user through each logical step of the analysis process, making it accessible to both novice and advanced users. This tool provides a seamless interface to the SimHap R package, while providing enhanced functionality such as sophisticated data checking, automated data conversion, and real-time estimations of haplotype simulation progress. SimHap GUI provides a novel, easy-to-use, cross-platform solution for conducting a range of genetic and non-genetic association analyses. This provides a free alternative to commercial statistics packages that is specifically designed for genetic association analysis.

  12. Challenges of biological sample preparation for SIMS imaging of elements and molecules at subcellular resolution

    NASA Astrophysics Data System (ADS)

    Chandra, Subhash

    2008-12-01

    Secondary ion mass spectrometry (SIMS) based imaging techniques capable of subcellular resolution characterization of elements and molecules are becoming valuable tools in many areas of biology and medicine. Due to high vacuum requirements of SIMS, the live cells cannot be analyzed directly in the instrument. The sample preparation, therefore, plays a critical role in preserving the native chemical composition for SIMS analysis. This work focuses on the evaluation of frozen-hydrated and frozen freeze-dried sample preparations for SIMS studies of cultured cells with a CAMECA IMS-3f dynamic SIMS ion microscope instrument capable of producing SIMS images with a spatial resolution of 500 nm. The sandwich freeze-fracture method was used for fracturing the cells. The complimentary fracture planes in the plasma membrane were characterized by field-emission secondary electron microscopy (FESEM) in the frozen-hydrated state. The cells fractured at the dorsal surface were used for SIMS analysis. The frozen-hydrated SIMS analysis of individual cells under dynamic primary ion beam (O 2+) revealed local secondary ion signal enhancements correlated with the water image signals of 19(H 3O) +. A preferential removal of water from the frozen cell matrix in the Z-axis was also observed. These complications render the frozen-hydrated sample type less desirable for subcellular dynamic SIMS studies. The freeze-drying of frozen-hydrated cells, either inside the instrument or externally in a freeze-drier, allowed SIMS imaging of subcellular chemical composition. Morphological evaluations of fractured freeze-dried cells with SEM and confocal laser scanning microscopy (CLSM) revealed well-preserved mitochondria, Golgi apparatus, and stress fibers. SIMS analysis of fractured freeze-dried cells revealed well-preserved chemical composition of even the most highly diffusible ions like K + and Na + in physiologically relevant concentrations. The high K-low Na signature in individual cells provided a rule-of-thumb criterion for the validation of sample preparation. The fractured freeze-dried cells allowed 3-D SIMS imaging and localization of 13C 15N labeled molecules and therapeutic drugs containing an elemental tag. Examples are shown to demonstrate that both diffusible elements and molecules are prone to artifact-induced relocation at subcellular scale if the sample preparation is compromised. The sample preparation is problem dependent and may vary widely between the diverse sample types of biological systems and the type of instrument used for SIMS analysis. The sample preparation, however, must be validated so that SIMS can be applied with confidence in biology and medicine.

  13. NanoSIMS for biological applications: Current practices and analyses

    DOE PAGES

    Nunez, Jamie R.; Renslow, Ryan S.; Cliff, III, John B.; ...

    2017-09-27

    Secondary ion mass spectrometry (SIMS) has become an increasingly utilized tool in biologically-relevant studies. Of these, high lateral resolution methodologies using the NanoSIMS 50/50L have been especially powerful within many biological fields over the past decade. Here, we provide a review of this technology, sample preparation and analysis considerations, examples of recent biological studies, data analysis, and current outlooks. Specifically, we offer an overview of SIMS and development of the NanoSIMS. We describe the major experimental factors that should be considered prior to NanoSIMS analysis and then provide information on best practices for data analysis and image generation, which includesmore » an in-depth discussion of appropriate colormaps. Additionally, we provide an open-source method for data representation that allows simultaneous visualization of secondary electron and ion information within a single image. Lastly, we present a perspective on the future of this technology and where we think it will have the greatest impact in near future.« less

  14. NanoSIMS for biological applications: Current practices and analyses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nunez, Jamie R.; Renslow, Ryan S.; Cliff, III, John B.

    Secondary ion mass spectrometry (SIMS) has become an increasingly utilized tool in biologically-relevant studies. Of these, high lateral resolution methodologies using the NanoSIMS 50/50L have been especially powerful within many biological fields over the past decade. Here, we provide a review of this technology, sample preparation and analysis considerations, examples of recent biological studies, data analysis, and current outlooks. Specifically, we offer an overview of SIMS and development of the NanoSIMS. We describe the major experimental factors that should be considered prior to NanoSIMS analysis and then provide information on best practices for data analysis and image generation, which includesmore » an in-depth discussion of appropriate colormaps. Additionally, we provide an open-source method for data representation that allows simultaneous visualization of secondary electron and ion information within a single image. Lastly, we present a perspective on the future of this technology and where we think it will have the greatest impact in near future.« less

  15. SimHap GUI: An intuitive graphical user interface for genetic association analysis

    PubMed Central

    Carter, Kim W; McCaskie, Pamela A; Palmer, Lyle J

    2008-01-01

    Background Researchers wishing to conduct genetic association analysis involving single nucleotide polymorphisms (SNPs) or haplotypes are often confronted with the lack of user-friendly graphical analysis tools, requiring sophisticated statistical and informatics expertise to perform relatively straightforward tasks. Tools, such as the SimHap package for the R statistics language, provide the necessary statistical operations to conduct sophisticated genetic analysis, but lacks a graphical user interface that allows anyone but a professional statistician to effectively utilise the tool. Results We have developed SimHap GUI, a cross-platform integrated graphical analysis tool for conducting epidemiological, single SNP and haplotype-based association analysis. SimHap GUI features a novel workflow interface that guides the user through each logical step of the analysis process, making it accessible to both novice and advanced users. This tool provides a seamless interface to the SimHap R package, while providing enhanced functionality such as sophisticated data checking, automated data conversion, and real-time estimations of haplotype simulation progress. Conclusion SimHap GUI provides a novel, easy-to-use, cross-platform solution for conducting a range of genetic and non-genetic association analyses. This provides a free alternative to commercial statistics packages that is specifically designed for genetic association analysis. PMID:19109877

  16. Visualizing Single Cell Biology: Nanosims Studies of Carbon and Nitrogen Metabolism in Diazotrophic Cyanobacteria

    NASA Astrophysics Data System (ADS)

    Pett-Ridge, J.; Finzi, J. A.; Capone, D. G.; Popa, R.; Nealson, K. H.; Ng, W.; Spormann, A. M.; Hutcheon, I. D.; Weber, P. K.

    2007-12-01

    Filamentous nitrogen fixing (diazotrophic) cyanobacteria are key players in global nutrient cycling, but the relationship between CO2- and N2-fixation and intercellular exchange of these elements remains poorly understood in many genera. These bacteria are faced with the challenge of isolating regions of N-fixation (O2 inhibited) and photosynthetic (O2 producing) activity. We used isotope labeling in conjunction with a high-resolution isotope and elemental mapping technique (NanoSIMS) to quantitatively describe 13C and 15N uptake and transport in two aquatic cyanobacteria grown on NaH13CO3 and 15N2. The technical challenges of tracing isotopes within individual bacteria can be overcome with high resolution Secondary Ion Mass Spectrometry (NanoSIMS). In NanoSIMS analysis, samples are sputtered with an energetic primary beam (Cs+, O-) liberating secondary ions that are separated by the mass spectrometer and detected in a suite of electron multipliers. Five isotopic species may be analyzed concurrently with spatial resolution as fine as 50nm. A high sensitivity isotope ratio 'map' can then be generated for the analyzed area. Using sequentially harvested cyanobacteria in conjunction with enriched H13CO3 and 15N2 incubations, we measured temporal enrichment patterns that evolve over the course of a day's growth and suggest tightly regulated changes in fixation kinetics. With a combination of TEM, SEM and NanoSIMS analyses, we also mapped the distribution of C, N and Mo (a critical nitrogenase co-factor) isotopes in intact cells. Our results suggest that NanoSIMS mapping of metal enzyme co-factors may be a powerful method of identifying physiological and morphological characteristics within individual bacterial cells, and could be used to provide a 3-dimensional context for more traditional analyses such as immunogold labeling. Finally, we resolved patterns of isotope enrichment at multiple spatial scales: sub-cellular variation, cell-cell differences along filaments, inter-species transfers (with Rhizobium epibionts), and within-cell depth profiles. Spatial enrichment patterns were correlated with morphological features evidenced in TEM images of microtomed filaments. These features indicate how 15N and 13C "hotspots" are dispersed throughout individual cells in different species, and may indicate isolated locations of increased N2 fixation, sites of amino acid/protein synthesis, or cyanophycin storage granules. This combination of Nano-Secondary Ion Mass Spectrometry (NanoSIMS) analysis and high resolution microscopy allows isotopic analysis to be linked to morphological features and holds great promise for fine-scale studies of bacteria metabolism.

  17. Imaging cellular structures in super-resolution with SIM, STED and Localisation Microscopy: A practical comparison.

    PubMed

    Wegel, Eva; Göhler, Antonia; Lagerholm, B Christoffer; Wainman, Alan; Uphoff, Stephan; Kaufmann, Rainer; Dobbie, Ian M

    2016-06-06

    Many biological questions require fluorescence microscopy with a resolution beyond the diffraction limit of light. Super-resolution methods such as Structured Illumination Microscopy (SIM), STimulated Emission Depletion (STED) microscopy and Single Molecule Localisation Microscopy (SMLM) enable an increase in image resolution beyond the classical diffraction-limit. Here, we compare the individual strengths and weaknesses of each technique by imaging a variety of different subcellular structures in fixed cells. We chose examples ranging from well separated vesicles to densely packed three dimensional filaments. We used quantitative and correlative analyses to assess the performance of SIM, STED and SMLM with the aim of establishing a rough guideline regarding the suitability for typical applications and to highlight pitfalls associated with the different techniques.

  18. ToF-SIMS PCA analysis of Myrtus communis L.

    NASA Astrophysics Data System (ADS)

    Piras, F. M.; Dettori, M. F.; Magnani, A.

    2009-06-01

    Nowadays there is a growing interest of researchers for the application of sophisticated analytical techniques in conjunction with statistical data analysis methods to the characterization of natural products to assure their authenticity and quality, and for the possibility of direct analysis of food to obtain maximum information. In this work, time-of-flight secondary ion mass spectrometry (ToF-SIMS) in conjunction with principal components analysis (PCA) are applied to study the chemical composition and variability of Sardinian myrtle ( Myrtus communis L.) through the analysis of both berries alcoholic extracts and berries epicarp. ToF-SIMS spectra of berries epicarp show that the epicuticular waxes consist mainly of carboxylic acids with chain length ranging from C20 to C30, or identical species formed from fragmentation of long-chain esters. PCA of ToF-SIMS data from myrtle berries epicarp distinguishes two groups characterized by a different surface concentration of triacontanoic acid. Variability in antocyanins, flavonols, α-tocopherol, and myrtucommulone contents is showed by ToF-SIMS PCA analysis of myrtle berries alcoholic extracts.

  19. Chemical imaging of molecular changes in a hydrated single cell by dynamic secondary ion mass spectrometry and super-resolution microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hua, Xin; Szymanski, Craig; Wang, Zhaoying

    2016-01-01

    Chemical imaging of single cells is important in capturing biological dynamics. Single cell correlative imaging is realized between structured illumination microscopy (SIM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS) using System for Analysis at the Liquid Vacuum Interface (SALVI), a multimodal microreactor. SIM characterized cells and guided subsequent ToF-SIMS analysis. Dynamic ToF-SIMS provided time- and space-resolved cell molecular mapping. Lipid fragments were identified in the hydrated cell membrane. Principal component analysis was used to elucidate chemical component differences among mouse lung cells that uptake zinc oxide nanoparticles. Our results provided submicron chemical spatial mapping for investigations of cell dynamics atmore » the molecular level.« less

  20. Liquid-phase microextraction for rapid AP-MALDI and quantitation of nortriptyline in biological matrices.

    PubMed

    Wu, Hui-Fen; Ku, Hsin-Yi; Yen, Jyh-Hao

    2008-07-01

    A liquid-phase microextraction (LPME) method using a micropipette with disposable tips was demonstrated for coupling to atmospheric pressure MALDI-MS (AP-MALDI/MS) as a concentrating probe for rapid analysis and quantitative determination of nortriptyline drug from biological matrices including human urine and human plasma. This technique was named as micropipette extraction (MPE). The best optimized parameters of MPE coupled to AP-MALDI/MS experiments were extraction solvent, toluene; extraction time, 5 min; sample agitation rate, 480 rpm; sample pH, 7; salt concentration, 30%; hole size of micropipette tips, 0.61 mm (id); and matrix concentration, 1000 ppm using alpha-cyano-4-hydroxycinnamic acid (CHCA) as a matrix. Three detection modes of AP-MALDI/MS analysis including full scan, selective ion monitor (SIM), and selective reaction monitor (SRM) of MS/MS were also compared for the MPE performance. The results clearly demonstrated that the MS/MS method provides a wider linear range and lower LODs but poor RSDs than the full scan and SIM methods. The LOD values for the MPE under SIM and MS/MS modes in water, urine, and plasma were 6.26, 47.5, and 94.9 nM, respectively. The enrichment factors (EFs) of this current approach were 36.5-43.0 fold in water. In addition, compared to single drop microextraction (SDME) and LPME using a dual gauge microsyringe with a hollow fiber (LPME-HF) technique, the LODs acquired by the MPE method under MS/MS modes were comparable to those of LPME-HF and SDME but it is more convenient than both methods. The advantages of this novel method are simple, easy to use, low cost, and no contamination between experiments since disposable tips were used for the micropipettes. The MPE has the potential to be widely used in the future because it only requires a simple micropipette to perform all extraction processes. We believe that this technique can be a powerful tool for MALDI/MS analysis of biological samples and clinical applications.

  1. Analysis techniques for tracer studies of oxidation. M. S. Thesis Final Report

    NASA Technical Reports Server (NTRS)

    Basu, S. N.

    1984-01-01

    Analysis techniques to obtain quantitative diffusion data from tracer concentration profiles were developed. Mass balance ideas were applied to determine the mechanism of oxide growth and to separate the fraction of inward and outward growth of oxide scales. The process of inward oxygen diffusion with exchange was theoretically modelled and the effect of lattice diffusivity, grain boundary diffusivity and grain size on the tracer concentration profile was studied. The development of the tracer concentration profile in a growing oxide scale was simulated. The double oxidation technique was applied to a FeCrAl-Zr alloy using 0-18 as a tracer. SIMS was used to obtain the tracer concentration profile. The formation of lacey oxide on the alloy was discussed. Careful consideration was given to the quality of data required to obtain quantitative information.

  2. Photo ion spectrometer

    DOEpatents

    Gruen, Dieter M.; Young, Charles E.; Pellin, Michael J.

    1989-01-01

    A method and apparatus for extracting for quantitative analysis ions of selected atomic components of a sample. A lens system is configured to provide a slowly diminishing field region for a volume containing the selected atomic components, enabling accurate energy analysis of ions generated in the slowly diminishing field region. The lens system also enables focusing on a sample of a charged particle beam, such as an ion beam, along a path length perpendicular to the sample and extraction of the charged particles along a path length also perpendicular to the sample. Improvement of signal to noise ratio is achieved by laser excitation of ions to selected autoionization states before carrying out quantitative analysis. Accurate energy analysis of energetic charged particles is assured by using a preselected resistive thick film configuration disposed on an insulator substrate for generating predetermined electric field boundary conditions to achieve for analysis the required electric field potential. The spectrometer also is applicable in the fields of SIMS, ISS and electron spectroscopy.

  3. Photo ion spectrometer

    DOEpatents

    Gruen, D.M.; Young, C.E.; Pellin, M.J.

    1989-08-08

    A method and apparatus are described for extracting for quantitative analysis ions of selected atomic components of a sample. A lens system is configured to provide a slowly diminishing field region for a volume containing the selected atomic components, enabling accurate energy analysis of ions generated in the slowly diminishing field region. The lens system also enables focusing on a sample of a charged particle beam, such as an ion beam, along a path length perpendicular to the sample and extraction of the charged particles along a path length also perpendicular to the sample. Improvement of signal to noise ratio is achieved by laser excitation of ions to selected auto-ionization states before carrying out quantitative analysis. Accurate energy analysis of energetic charged particles is assured by using a preselected resistive thick film configuration disposed on an insulator substrate for generating predetermined electric field boundary conditions to achieve for analysis the required electric field potential. The spectrometer also is applicable in the fields of SIMS, ISS and electron spectroscopy. 8 figs.

  4. Quantitative Analysis of Tetramethylenedisulfotetramine ("Tetramine") Spiked into Beverages by Liquid Chromatography Tandem Mass Spectrometry with Validation by Gas Chromatography Mass Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owens, J; Hok, S; Alcaraz, A

    Tetramethylenedisulfotetramine, commonly known as tetramine, is a highly neurotoxic rodenticide (human oral LD{sub 50} = 0.1 mg/kg) used in hundreds of deliberate food poisoning events in China. Here we describe a method for quantitation of tetramine spiked into beverages, including milk, juice, tea, cola, and water and cleaned up by C8 solid phase extraction and liquid-liquid extraction. Quantitation by high performance liquid chromatography tandem mass spectrometry (LC/MS/MS) was based upon fragmentation of m/z 347 to m/z 268. The method was validated by gas chromatography mass spectrometry (GC/MS) operated in SIM mode for ions m/z 212, 240, and 360. The limitmore » of quantitation was 0.10 {micro}g/mL by LC/MS/MS versus 0.15 {micro}g/mL for GC/MS. Fortifications of the beverages at 2.5 {micro}g/mL and 0.25 {micro}g/mL were recovered ranging from 73-128% by liquid-liquid extraction for GC/MS analysis, 13-96% by SPE and 10-101% by liquid-liquid extraction for LC/MS/MS analysis.« less

  5. Alteration of the RANKL/RANK/OPG System in Periprosthetic Osteolysis with Septic Loosening.

    PubMed

    Wang, Long; Dai, Zixun; Xie, Jie; Liao, Hao; Lv, Cheng; Hu, Yihe

    2016-02-01

    The pathogenesis of periprosthetic osteolysis with septic loosening remains incompletely understood. The purpose of this study was to investigate whether expression of the RANKL/RANK/OPG system is altered in septic interface membranes (SIMs). Seventeen cases with a SIM, 26 cases with an aseptic interface membrane (AIM), and 12 cases with a normal synovium (NS) were assessed. Scanning and transmission electron microscopy (SEM and TEM, respectively) were used to observe the microscopic morphology of three tissue conditions. Differences in RANKL, RANK, and OPG expression at the mRNA level were assessed by real-time quantitative PCR, and differences at the protein level were assessed by immunohistochemical staining and Western blotting. SEM showed wear debris widely distributed on the AIM surface, and TEM showed Bacillus activity in the SIM. RANKL expression and the RANKL/OPG ratio were significantly increased in SIMs. Imbalance in the RANKL/RANK/OPG system is related to periprosthetic osteolysis with septic loosening but is not the only possible pathogenic mechanism.

  6. Molecular imaging of enhanced Na + expression in the liver of total sleep deprived rats by TOF-SIMS

    NASA Astrophysics Data System (ADS)

    Chang, Hung-Ming; Chen, Bo-Jung; Wu, Un-In; Huang, Yi-Lun; Mai, Fu-Der

    2008-12-01

    Sleep disorder is associated with metabolic disturbances, which was related to oxidative stress and subsequently sodium overload. Since liver plays important roles in metabolic regulation, present study is aimed to determine whether hepatic sodium, together with oxidative stress, would significantly alter after total sleep deprivation (TSD). Sodium ion was investigated by time-of-flight secondary ion mass spectrometry (TOF-SIMS). Parameter for oxidative stress was examined by heat shock protein-25 (HSP-25) immunohistochemistry. TOF-SIMS spectrum indicated that hepatic Na +/K + ratio counting as 82.41 ± 9.5 was obtained in normal rats. Sodium ions were distributed in hepatocytes with several aggregations. However, following TSD, the intensity for Na +/K + ratio was relatively increased (101.94 ± 6.9) and signals for sodium image were strongly expressed throughout hepatocytes without spatial localization. Quantitative analysis revealed that HSP-25 staining intensity is 1.78 ± 0.27 in TSD rats, which was significantly higher than that of normal ones (0.68 ± 0.15). HSP-25 augmentation suggests that hepatocytes suffer from oxidative stress following TSD. Concerning oxidative stress induced sodium overload would impair metabolic function; enhanced hepatic sodium expression after TSD may be a major cause of TSD relevant metabolic diseases.

  7. Rapid determination of 1-deoxynojirimycin in Morus alba L. leaves by direct analysis in real time (DART) mass spectrometry.

    PubMed

    Xu, Bin; Zhang, Dong-Yang; Liu, Ze-Yu; Zhang, Ying; Liu, Li; Li, Long; Liu, Charles C; Wu, Guo-Hua

    2015-10-10

    A new method based on a Direct Analysis in Real Time (DART) ionization source coupled with triple quadrupole tandem mass spectrometry has been developed for rapid qualitative and quantitative analyses of 1-deoxynojirimycin (DNJ) in mulberry leaves. Two ions produced from DNJ, [M+H](+) (m/z 164) and [M-2H+H](+) (m/z 162), are observed using DART-MS in the positive ion mode. The peak areas of the two selected ions monitoring (SIM) signals of ([M+H](+) (m/z 164) and [M-2H+H](+) (m/z 162)) are integrated to determine the peak area for quantitative analyses. A reasonable linear regression equation is obtained in the range of 1.01 to 40.50 μg/mL, with a linear coefficient (R(2)) of 0.996. The limits of detection (LOD) and quantification (LOQ) of the method are 0.25 and 0.80 μg/mL, respectively. The range of recovery is shown to be 87.73-95.61%. The results derived from the developed DART-MS method are in good agreement with those from the conventional HPLC-FLD method. By contrast, DART-MS in SIM mode is a simple, rapid and high-throughput approach for the determination of the DNJ content in mulberry leaves. The present method is advantageous for the rapid screening of mulberry leaves containing high DNJ contents. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Role of ghrelin in small intestinal motility following pediatric intracerebral hemorrhage in mice.

    PubMed

    Zan, Jieyu; Song, Lei; Wang, Jiejie; Zou, Rong; Hong, Fei; Zhao, Jinhua; Cheng, Yijun; Xu, Ming

    2017-11-01

    Small intestinal motility (SIM) disorder is a common complication following pediatric intracerebral hemorrhage (ICH), leading to a poor prognosis in patients. Previous studies have shown that ghrelin is involved in SIM in various diseases; however, the role of ghrelin in pediatric ICH‑induced SIM disorder remains to be elucidated. The present study was designed to investigate the association between ghrelin and SIM post‑ICH, and to examine the effect of exogenous ghrelin administration on SIM in vivo. An ICH model was induced in mice by autologous blood infusion. Neurobehavioral deficits were evaluated using a Rotarod test, forelimb placing test, and corner turn test. Intestinal mucosal damage was examined using hematoxylin and eosin staining. SIM was measured using charcoal meal staining. An enzyme‑linked immunosorbent assay was used to evaluate serum levels of ghrelin and nitric oxide (NO). Reverse transcription‑quantitative polymerase chain reaction and western blot analyses were performed to determine the levels of inducible nitric oxide synthase (iNOS), neuronal nitric oxide synthase (nNOS) and endothelial nitric oxide synthase (eNOS) at the mRNA and protein levels. Nω‑nitro‑L‑arginine methyl ester hydrochloride (L‑NAME), L‑arginine, atropine, phentolamine and propranolol were used to manipulate the putative pathways induced by ghrelin. Neurological dysfunction was observed post‑ICH. ICH caused damage to the intestinal mucosa and delayed SIM. Serum levels of ghrelin increased between 3 h and 3 days, peaking at 12 h, and showed a significant negative correlation with SIM post‑ICH. Ghrelin administration dose‑dependently attenua-ted ICH‑induced SIM disorder. Ghrelin also decreased NO levels by downregulating the mRNA and protein expression levels of iNOS, but not those of nNOS or eNOS, post‑ICH. Consistently, the effect was enhanced by L‑NAME and weakened by L‑arginine, respectively. The protective effect of ghrelin was eradicated by atropine, but not phentolamine or propranolol. These findings suggested that ghrelin ameliorated SIM disorder by downregulating iNOS/NO via the cholinergic pathway. Therefore, ghrelin may serve as a potential biomarker and useful target in ICH‑induced SIM disorder.

  9. Quantitative spectroscopic analyses in the IACOB+OWN project: Massive O-type stars in the Galaxy with the current Gaia information

    NASA Astrophysics Data System (ADS)

    Holgado, Gonzalo; Simón-Díaz, Sergio; Barbá, Rodolfo

    2017-11-01

    We present the results from the quantitative spectroscopic analysis of ~280 likely single O stars targeted by the IACOB and OWN surveys. This implies the largest sample of Galactic O-type stars analyzed homogeneously to date. We used the iacob-broad and iacob-gbat tools (see Simón-Díaz et al. 2011,2015) to obtain the complete set of spectroscopic parameters which can be determined from the optical spectrum of O-type stars: projected rotational velocity (v sin i), macroturbulence velocity (v mac), effective temperature (T eff), gravity (logg), wind-strength (logQ), helium abundance (Y He), microturbulence (ξt), and the exponent of the wind-law (β).

  10. Modeling wildlife populations with HexSim

    EPA Science Inventory

    HexSim is a framework for constructing spatially-explicit, individual-based computer models designed for simulating terrestrial wildlife population dynamics and interactions. HexSim is useful for a broad set of modeling applications including population viability analysis for on...

  11. SIMS analysis of extended impact features on LDEF experiment

    NASA Technical Reports Server (NTRS)

    Amari, S.; Foote, J.; Jessberger, E. K.; Simon, C.; Stadermann, F. J.; Swan, P.; Walker, R.; Zinner, E.

    1991-01-01

    Discussed here are the first Secondary Ion Mass Spectroscopy (SIMS) analysis of projectile material deposited in extended impact features on Ge wafers from the trailing edge. Although most capture cells lost their plastic film covers, they contain extended impact features that apparently were produced by high velocity impacts when the plastic foils were still intact. Detailed optical scanning of all bare capture cells from the trailing edge revealed more than 100 impacts. Fifty-eight were selected by scanning electron microscope (SEM) inspection as prime candidates for SIMS analysis. Preliminary SIMS measurements were made on 15 impacts. More than half showed substantial enhancements of Mg, Al, Si, Ca, and Fe in the impact region, indicating micrometeorites as the projectiles.

  12. Biochemical imaging of tissues by SIMS for biomedical applications

    NASA Astrophysics Data System (ADS)

    Lee, Tae Geol; Park, Ji-Won; Shon, Hyun Kyong; Moon, Dae Won; Choi, Won Woo; Li, Kapsok; Chung, Jin Ho

    2008-12-01

    With the development of optimal surface cleaning techniques by cluster ion beam sputtering, certain applications of SIMS for analyzing cells and tissues have been actively investigated. For this report, we collaborated with bio-medical scientists to study bio-SIMS analyses of skin and cancer tissues for biomedical diagnostics. We pay close attention to the setting up of a routine procedure for preparing tissue specimens and treating the surface before obtaining the bio-SIMS data. Bio-SIMS was used to study two biosystems, skin tissues for understanding the effects of photoaging and colon cancer tissues for insight into the development of new cancer diagnostics for cancer. Time-of-flight SIMS imaging measurements were taken after surface cleaning with cluster ion bombardment by Bi n or C 60 under varying conditions. The imaging capability of bio-SIMS with a spatial resolution of a few microns combined with principal component analysis reveal biologically meaningful information, but the lack of high molecular weight peaks even with cluster ion bombardment was a problem. This, among other problems, shows that discourse with biologists and medical doctors are critical to glean any meaningful information from SIMS mass spectrometric and imaging data. For SIMS to be accepted as a routine, daily analysis tool in biomedical laboratories, various practical sample handling methodology such as surface matrix treatment, including nano-metal particles and metal coating, in addition to cluster sputtering, should be studied.

  13. 40 CFR Appendix C to Part 300 - Swirling Flask Dispersant Effectiveness Test, Revised Standard Dispersant Toxicity Test, and...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the SIM mode at a scan rate of 1.5 scans/second to maximize the linear quantitative range and... Research Group, Texas A&M University, 833 Graham Rd., College Station, TX, 77845, (409) 690-0095. 8... following information is contained in the detailed quantitative reports: average RRF derived from the...

  14. ToF-SIMS analysis of a polymer microarray composed of poly(meth)acrylates with C6 derivative pendant groups.

    PubMed

    Hook, Andrew L; Scurr, David J

    2016-04-01

    Surface analysis plays a key role in understanding the function of materials, particularly in biological environments. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) provides highly surface sensitive chemical information that can readily be acquired over large areas and has, thus, become an important surface analysis tool. However, the information-rich nature of ToF-SIMS complicates the interpretation and comparison of spectra, particularly in cases where multicomponent samples are being assessed. In this study, a method is presented to assess the chemical variance across 16 poly(meth)acrylates. Materials are selected to contain C 6 pendant groups, and ten replicates of each are printed as a polymer microarray. SIMS spectra are acquired for each material with the most intense and unique ions assessed for each material to identify the predominant and distinctive fragmentation pathways within the materials studied. Differentiating acrylate/methacrylate pairs is readily achieved using secondary ions derived from both the polymer backbone and pendant groups. Principal component analysis (PCA) is performed on the SIMS spectra of the 16 polymers, whereby the resulting principal components are able to distinguish phenyl from benzyl groups, mono-functional from multi-functional monomers and acrylates from methacrylates. The principal components are applied to copolymer series to assess the predictive capabilities of the PCA. Beyond being able to predict the copolymer ratio, in some cases, the SIMS analysis is able to provide insight into the molecular sequence of a copolymer. The insight gained in this study will be beneficial for developing structure-function relationships based upon ToF-SIMS data of polymer libraries. © 2016 The Authors Surface and Interface Analysis Published by John Wiley & Sons Ltd.

  15. TOFSIMS-P: a web-based platform for analysis of large-scale TOF-SIMS data.

    PubMed

    Yun, So Jeong; Park, Ji-Won; Choi, Il Ju; Kang, Byeongsoo; Kim, Hark Kyun; Moon, Dae Won; Lee, Tae Geol; Hwang, Daehee

    2011-12-15

    Time-of-flight secondary ion mass spectrometry (TOF-SIMS) has been a useful tool to profile secondary ions from the near surface region of specimens with its high molecular specificity and submicrometer spatial resolution. However, the TOF-SIMS analysis of even a moderately large size of samples has been hampered due to the lack of tools for automatically analyzing the huge amount of TOF-SIMS data. Here, we present a computational platform to automatically identify and align peaks, find discriminatory ions, build a classifier, and construct networks describing differential metabolic pathways. To demonstrate the utility of the platform, we analyzed 43 data sets generated from seven gastric cancer and eight normal tissues using TOF-SIMS. A total of 87 138 ions were detected from the 43 data sets by TOF-SIMS. We selected and then aligned 1286 ions. Among them, we found the 66 ions discriminating gastric cancer tissues from normal ones. Using these 66 ions, we then built a partial least square-discriminant analysis (PLS-DA) model resulting in a misclassification error rate of 0.024. Finally, network analysis of the 66 ions showed disregulation of amino acid metabolism in the gastric cancer tissues. The results show that the proposed framework was effective in analyzing TOF-SIMS data from a moderately large size of samples, resulting in discrimination of gastric cancer tissues from normal tissues and identification of biomarker candidates associated with the amino acid metabolism.

  16. Nanowire dopant measurement using secondary ion mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chia, A. C. E.; Boulanger, J. P.; Wood, B. A.

    2015-09-21

    A method is presented to improve the quantitative determination of dopant concentration in semiconductor nanowire (NW) arrays using secondary ion mass spectrometry (SIMS). SIMS measurements were used to determine Be dopant concentrations in a Be-doped GaAs thin film and NW arrays of various pitches that were dry-etched from the same film. A comparison of these measurements revealed a factor of 3 to 12 difference, depending on the NW array pitch, between the secondary Be ion yields of the film and the NW arrays, despite being identically doped. This was due to matrix effects and ion beam mixing of Be frommore » the NWs into the surrounding benzocyclobutene that was used to fill the space between the NWs. This indicates the need for etched NWs to be used as doping standards instead of 2D films when evaluating NWs of unknown doping by SIMS. Using the etched NWs as doping standards, NW arrays of various pitches grown by the vapour-liquid-solid mechanism were characterized by SIMS to yield valuable insights into doping mechanisms.« less

  17. siMS Score: Simple Method for Quantifying Metabolic Syndrome.

    PubMed

    Soldatovic, Ivan; Vukovic, Rade; Culafic, Djordje; Gajic, Milan; Dimitrijevic-Sreckovic, Vesna

    2016-01-01

    To evaluate siMS score and siMS risk score, novel continuous metabolic syndrome scores as methods for quantification of metabolic status and risk. Developed siMS score was calculated using formula: siMS score = 2*Waist/Height + Gly/5.6 + Tg/1.7 + TAsystolic/130-HDL/1.02 or 1.28 (for male or female subjects, respectively). siMS risk score was calculated using formula: siMS risk score = siMS score * age/45 or 50 (for male or female subjects, respectively) * family history of cardio/cerebro-vascular events (event = 1.2, no event = 1). A sample of 528 obese and non-obese participants was used to validate siMS score and siMS risk score. Scores calculated as sum of z-scores (each component of metabolic syndrome regressed with age and gender) and sum of scores derived from principal component analysis (PCA) were used for evaluation of siMS score. Variants were made by replacing glucose with HOMA in calculations. Framingham score was used for evaluation of siMS risk score. Correlation between siMS score with sum of z-scores and weighted sum of factors of PCA was high (r = 0.866 and r = 0.822, respectively). Correlation between siMS risk score and log transformed Framingham score was medium to high for age groups 18+,30+ and 35+ (0.835, 0.707 and 0.667, respectively). siMS score and siMS risk score showed high correlation with more complex scores. Demonstrated accuracy together with superior simplicity and the ability to evaluate and follow-up individual patients makes siMS and siMS risk scores very convenient for use in clinical practice and research as well.

  18. Integration of SimSET photon history generator in GATE for efficient Monte Carlo simulations of pinhole SPECT.

    PubMed

    Chen, Chia-Lin; Wang, Yuchuan; Lee, Jason J S; Tsui, Benjamin M W

    2008-07-01

    The authors developed and validated an efficient Monte Carlo simulation (MCS) workflow to facilitate small animal pinhole SPECT imaging research. This workflow seamlessly integrates two existing MCS tools: simulation system for emission tomography (SimSET) and GEANT4 application for emission tomography (GATE). Specifically, we retained the strength of GATE in describing complex collimator/detector configurations to meet the anticipated needs for studying advanced pinhole collimation (e.g., multipinhole) geometry, while inserting the fast SimSET photon history generator (PHG) to circumvent the relatively slow GEANT4 MCS code used by GATE in simulating photon interactions inside voxelized phantoms. For validation, data generated from this new SimSET-GATE workflow were compared with those from GATE-only simulations as well as experimental measurements obtained using a commercial small animal pinhole SPECT system. Our results showed excellent agreement (e.g., in system point response functions and energy spectra) between SimSET-GATE and GATE-only simulations, and, more importantly, a significant computational speedup (up to approximately 10-fold) provided by the new workflow. Satisfactory agreement between MCS results and experimental data were also observed. In conclusion, the authors have successfully integrated SimSET photon history generator in GATE for fast and realistic pinhole SPECT simulations, which can facilitate research in, for example, the development and application of quantitative pinhole and multipinhole SPECT for small animal imaging. This integrated simulation tool can also be adapted for studying other preclinical and clinical SPECT techniques.

  19. Secondary ion mass spectrometry: The application in the analysis of atmospheric particulate matter

    DOE PAGES

    Huang, Di; Hua, Xin; Xiu, Guang-Li; ...

    2017-07-24

    Currently, considerable attention has been paid to atmospheric particulate matter (PM) investigation due to its importance in human health and global climate change. Surface characterization, single particle analysis and depth profiling of PM is important for a better understanding of its formation processes and predicting its impact on the environment and human being. Secondary ion mass spectrometry (SIMS) is a surface technique with high surface sensitivity, high spatial resolution chemical imaging and unique depth profiling capabilities. Recent research shows that SIMS has great potential in analyzing both surface and bulk chemical information of PM. In this review, we give amore » brief introduction of SIMS working principle and survey recent applications of SIMS in PM characterization. In particular, analyses from different types of PM sources by various SIMS techniques were discussed concerning their advantages and limitations. Finally, we propose, the future development and needs of SIMS in atmospheric aerosol measurement with a perspective in broader environmental sciences.« less

  20. Secondary ion mass spectrometry: The application in the analysis of atmospheric particulate matter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Di; Hua, Xin; Xiu, Guang-Li

    Currently, considerable attention has been paid to atmospheric particulate matter (PM) investigation due to its importance in human health and global climate change. Surface characterization, single particle analysis and depth profiling of PM is important for a better understanding of its formation processes and predicting its impact on the environment and human being. Secondary ion mass spectrometry (SIMS) is a surface technique with high surface sensitivity, high spatial resolution chemical imaging and unique depth profiling capabilities. Recent research shows that SIMS has great potential in analyzing both surface and bulk chemical information of PM. In this review, we give amore » brief introduction of SIMS working principle and survey recent applications of SIMS in PM characterization. In particular, analyses from different types of PM sources by various SIMS techniques were discussed concerning their advantages and limitations. Finally, we propose, the future development and needs of SIMS in atmospheric aerosol measurement with a perspective in broader environmental sciences.« less

  1. Open-source image reconstruction of super-resolution structured illumination microscopy data in ImageJ

    PubMed Central

    Müller, Marcel; Mönkemöller, Viola; Hennig, Simon; Hübner, Wolfgang; Huser, Thomas

    2016-01-01

    Super-resolved structured illumination microscopy (SR-SIM) is an important tool for fluorescence microscopy. SR-SIM microscopes perform multiple image acquisitions with varying illumination patterns, and reconstruct them to a super-resolved image. In its most frequent, linear implementation, SR-SIM doubles the spatial resolution. The reconstruction is performed numerically on the acquired wide-field image data, and thus relies on a software implementation of specific SR-SIM image reconstruction algorithms. We present fairSIM, an easy-to-use plugin that provides SR-SIM reconstructions for a wide range of SR-SIM platforms directly within ImageJ. For research groups developing their own implementations of super-resolution structured illumination microscopy, fairSIM takes away the hurdle of generating yet another implementation of the reconstruction algorithm. For users of commercial microscopes, it offers an additional, in-depth analysis option for their data independent of specific operating systems. As a modular, open-source solution, fairSIM can easily be adapted, automated and extended as the field of SR-SIM progresses. PMID:26996201

  2. Search for the direct production of charginos and neutralinos in final states with tau leptons in $$\\sqrt{s}$$ =13 TeV pp collisions with the ATLAS detector

    DOE PAGES

    Aaboud, M.; Aad, G.; Abbott, B.; ...

    2018-02-22

    Here, a search for the direct production of charginos and neutralinos in final states with at least two hadronically decaying tau leptons is presented. The analysis uses a dataset of pp collisions corresponding to an integrated luminosity of 36.1fb -1, recorded with the ATLAS detector at the Large Hadron Collider at a centre-of-mass energy of 13 TeV. No significant deviation from the expected Standard Model background is observed. Limits are derived in scenarios ofmore » $$\\sim\\atop{\\chi}$$ $$+\\atop{1}$$ $$\\sim\\atop{\\chi}$$ $$\\bar{1}$$ pair production and of $$\\sim\\atop{\\chi}$$ $$±\\atop{1}$$ $$\\sim\\atop{\\chi}$$ $$0\\atop{2}$$ and $$\\sim\\atop{\\chi}$$ $$+\\atop{1}$$ $$\\sim\\atop{\\chi}$$ $$\\bar{1}$$ production in simplified models where the neutralinos and charginos decay solely via intermediate left-handed staus and tau sneutrinos, and the mass of the $$\\sim\\atop{\\tau}_L$$ state is set to be halfway between the masses of the $$\\sim\\atop{\\chi}$$ $$±\\atop{1}$$ and the $$\\sim\\atop{\\chi}$$ $$0\\atop{1}$$. Chargino masses up to 630 GeV are excluded at 95% confidence level in the scenario of direct production of $$\\sim\\atop{\\chi}$$ $$+\\atop{1}$$ $$\\sim\\atop{\\chi}$$ $$\\bar{1}$$ for a massless $$\\sim\\atop{\\chi}$$ $$0\\atop{1}$$. Common $$\\sim\\atop{\\chi}$$ $$±\\atop{1}$$ and $$\\sim\\atop{\\chi}$$ $$0\\atop{2}$$ masses up to 760 GeV are excluded in the case of production of $$\\sim\\atop{\\chi}$$ $$±\\atop{1}$$ $$\\sim\\atop{\\chi}$$ $$0\\atop{2}$$ and $$\\sim\\atop{\\chi}$$ $$+\\atop{1}$$ $$\\sim\\atop{\\chi}$$ $$-\\atop{1}$$ assuming a massless $$\\sim\\atop{\\chi}$$ $$0\\atop{1}$$. Exclusion limits for additional benchmark scenarios with large and small mass-splitting between the Open image in new window $$\\sim\\atop{\\chi}$$ $$±\\atop{1}$$ and the $$\\sim\\atop{\\chi}$$ $$0\\atop{1}$$ are also studied by varying the $$\\sim\\atop{\\tau}_L$$ mass between the masses of the $$\\sim\\atop{\\chi}$$ $$±\\atop{1}$$ and the $$\\sim\\atop{\\chi}$$ $$0\\atop{1}$$.« less

  3. Search for the direct production of charginos and neutralinos in final states with tau leptons in $$\\sqrt{s}$$ =13 TeV pp collisions with the ATLAS detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aaboud, M.; Aad, G.; Abbott, B.

    Here, a search for the direct production of charginos and neutralinos in final states with at least two hadronically decaying tau leptons is presented. The analysis uses a dataset of pp collisions corresponding to an integrated luminosity of 36.1fb -1, recorded with the ATLAS detector at the Large Hadron Collider at a centre-of-mass energy of 13 TeV. No significant deviation from the expected Standard Model background is observed. Limits are derived in scenarios ofmore » $$\\sim\\atop{\\chi}$$ $$+\\atop{1}$$ $$\\sim\\atop{\\chi}$$ $$\\bar{1}$$ pair production and of $$\\sim\\atop{\\chi}$$ $$±\\atop{1}$$ $$\\sim\\atop{\\chi}$$ $$0\\atop{2}$$ and $$\\sim\\atop{\\chi}$$ $$+\\atop{1}$$ $$\\sim\\atop{\\chi}$$ $$\\bar{1}$$ production in simplified models where the neutralinos and charginos decay solely via intermediate left-handed staus and tau sneutrinos, and the mass of the $$\\sim\\atop{\\tau}_L$$ state is set to be halfway between the masses of the $$\\sim\\atop{\\chi}$$ $$±\\atop{1}$$ and the $$\\sim\\atop{\\chi}$$ $$0\\atop{1}$$. Chargino masses up to 630 GeV are excluded at 95% confidence level in the scenario of direct production of $$\\sim\\atop{\\chi}$$ $$+\\atop{1}$$ $$\\sim\\atop{\\chi}$$ $$\\bar{1}$$ for a massless $$\\sim\\atop{\\chi}$$ $$0\\atop{1}$$. Common $$\\sim\\atop{\\chi}$$ $$±\\atop{1}$$ and $$\\sim\\atop{\\chi}$$ $$0\\atop{2}$$ masses up to 760 GeV are excluded in the case of production of $$\\sim\\atop{\\chi}$$ $$±\\atop{1}$$ $$\\sim\\atop{\\chi}$$ $$0\\atop{2}$$ and $$\\sim\\atop{\\chi}$$ $$+\\atop{1}$$ $$\\sim\\atop{\\chi}$$ $$-\\atop{1}$$ assuming a massless $$\\sim\\atop{\\chi}$$ $$0\\atop{1}$$. Exclusion limits for additional benchmark scenarios with large and small mass-splitting between the Open image in new window $$\\sim\\atop{\\chi}$$ $$±\\atop{1}$$ and the $$\\sim\\atop{\\chi}$$ $$0\\atop{1}$$ are also studied by varying the $$\\sim\\atop{\\tau}_L$$ mass between the masses of the $$\\sim\\atop{\\chi}$$ $$±\\atop{1}$$ and the $$\\sim\\atop{\\chi}$$ $$0\\atop{1}$$.« less

  4. In Situ Characterization of Hydrated Proteins in Water by SALVI and ToF-SIMS

    PubMed Central

    Yu, Jiachao; Zhu, Zihua; Yu, Xiao-Ying

    2016-01-01

    This work demonstrates in situ characterization of protein biomolecules in the aqueous solution using the System for Analysis at the Liquid Vacuum Interface (SALVI) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The fibronectin protein film was immobilized on the silicon nitride (SiN) membrane that forms the SALVI detection area. During ToF-SIMS analysis, three modes of analysis were conducted including high spatial resolution mass spectrometry, two-dimensional (2D) imaging, and depth profiling. Mass spectra were acquired in both positive and negative modes. Deionized water was also analyzed as a reference sample. Our results show that the fibronectin film in water has more distinct and stronger water cluster peaks compared to water alone. Characteristic peaks of amino acid fragments are also observable in the hydrated protein ToF-SIMS spectra. These results illustrate that protein molecule adsorption on a surface can be studied dynamically using SALVI and ToF-SIMS in the liquid environment for the first time. PMID:26966995

  5. ToF-SIMS measurements with topographic information in combined images.

    PubMed

    Koch, Sabrina; Ziegler, Georg; Hutter, Herbert

    2013-09-01

    In 2D and 3D time-of-flight secondary ion mass spectrometric (ToF-SIMS) analysis, accentuated structures on the sample surface induce distorted element distributions in the measurement. The origin of this effect is the 45° incidence angle of the analysis beam, recording planar images with distortion of the sample surface. For the generation of correct element distributions, these artifacts associated with the sample surface need to be eliminated by measuring the sample surface topography and applying suitable algorithms. For this purpose, the next generation of ToF-SIMS instruments will feature a scanning probe microscope directly implemented in the sample chamber which allows the performance of topography measurements in situ. This work presents the combination of 2D and 3D ToF-SIMS analysis with topographic measurements by ex situ techniques such as atomic force microscopy (AFM), confocal microscopy (CM), and digital holographic microscopy (DHM). The concept of the combination of topographic and ToF-SIMS measurements in a single representation was applied to organic and inorganic samples featuring surface structures in the nanometer and micrometer ranges. The correct representation of planar and distorted ToF-SIMS images was achieved by the combination of topographic data with images of 2D as well as 3D ToF-SIMS measurements, using either AFM, CM, or DHM for the recording of topographic data.

  6. Structural analysis of poly-SUMO chain recognition by the RNF4-SIMs domain.

    PubMed

    Kung, Camy C-H; Naik, Mandar T; Wang, Szu-Huan; Shih, Hsiu-Ming; Chang, Che-Chang; Lin, Li-Ying; Chen, Chia-Lin; Ma, Che; Chang, Chi-Fon; Huang, Tai-Huang

    2014-08-15

    The E3 ubiquitin ligase RNF4 (RING finger protein 4) contains four tandem SIM [SUMO (small ubiquitin-like modifier)-interaction motif] repeats for selective interaction with poly-SUMO-modified proteins, which it targets for degradation. We employed a multi-faceted approach to characterize the structure of the RNF4-SIMs domain and the tetra-SUMO2 chain to elucidate the interaction between them. In solution, the SIM domain was intrinsically disordered and the linkers of the tetra-SUMO2 were highly flexible. Individual SIMs of the RNF4-SIMs domains bind to SUMO2 in the groove between the β2-strand and the α1-helix parallel to the β2-strand. SIM2 and SIM3 bound to SUMO with a high affinity and together constituted the recognition module necessary for SUMO binding. SIM4 alone bound to SUMO with low affinity; however, its contribution to tetra-SUMO2 binding avidity is comparable with that of SIM3 when in the RNF4-SIMs domain. The SAXS data of the tetra-SUMO2-RNF4-SIMs domain complex indicate that it exists as an ordered structure. The HADDOCK model showed that the tandem RNF4-SIMs domain bound antiparallel to the tetra-SUMO2 chain orientation and wrapped around the SUMO protamers in a superhelical turn without imposing steric hindrance on either molecule.

  7. WholeCellSimDB: a hybrid relational/HDF database for whole-cell model predictions

    PubMed Central

    Karr, Jonathan R.; Phillips, Nolan C.; Covert, Markus W.

    2014-01-01

    Mechanistic ‘whole-cell’ models are needed to develop a complete understanding of cell physiology. However, extracting biological insights from whole-cell models requires running and analyzing large numbers of simulations. We developed WholeCellSimDB, a database for organizing whole-cell simulations. WholeCellSimDB was designed to enable researchers to search simulation metadata to identify simulations for further analysis, and quickly slice and aggregate simulation results data. In addition, WholeCellSimDB enables users to share simulations with the broader research community. The database uses a hybrid relational/hierarchical data format architecture to efficiently store and retrieve both simulation setup metadata and results data. WholeCellSimDB provides a graphical Web-based interface to search, browse, plot and export simulations; a JavaScript Object Notation (JSON) Web service to retrieve data for Web-based visualizations; a command-line interface to deposit simulations; and a Python API to retrieve data for advanced analysis. Overall, we believe WholeCellSimDB will help researchers use whole-cell models to advance basic biological science and bioengineering. Database URL: http://www.wholecellsimdb.org Source code repository URL: http://github.com/CovertLab/WholeCellSimDB PMID:25231498

  8. Evaluation of biomolecular distributions in rat brain tissues by means of ToF-SIMS using a continuous beam of Ar clusters.

    PubMed

    Nakano, Shusuke; Yokoyama, Yuta; Aoyagi, Satoka; Himi, Naoyuki; Fletcher, John S; Lockyer, Nicholas P; Henderson, Alex; Vickerman, John C

    2016-06-08

    Time-of-flight secondary ion mass spectrometry (ToF-SIMS) provides detailed chemical structure information and high spatial resolution images. Therefore, ToF-SIMS is useful for studying biological phenomena such as ischemia. In this study, in order to evaluate cerebral microinfarction, the distribution of biomolecules generated by ischemia was measured with ToF-SIMS. ToF-SIMS data sets were analyzed by means of multivariate analysis for interpreting complex samples containing unknown information and to obtain biomolecular mapping indicated by fragment ions from the target biomolecules. Using conventional ToF-SIMS (primary ion source: Bi cluster ion), it is difficult to detect secondary ions beyond approximately 1000 u. Moreover, the intensity of secondary ions related to biomolecules is not always high enough for imaging because of low concentration even if the masses are lower than 1000 u. However, for the observation of biomolecular distributions in tissues, it is important to detect low amounts of biological molecules from a particular area of tissue. Rat brain tissue samples were measured with ToF-SIMS (J105, Ionoptika, Ltd., Chandlers Ford, UK), using a continuous beam of Ar clusters as a primary ion source. ToF-SIMS with Ar clusters efficiently detects secondary ions related to biomolecules and larger molecules. Molecules detected by ToF-SIMS were examined by analyzing ToF-SIMS data using multivariate analysis. Microspheres (45 μm diameter) were injected into the rat unilateral internal carotid artery (MS rat) to cause cerebral microinfarction. The rat brain was sliced and then measured with ToF-SIMS. The brain samples of a normal rat and the MS rat were examined to find specific secondary ions related to important biomolecules, and then the difference between them was investigated. Finally, specific secondary ions were found around vessels incorporating microspheres in the MS rat. The results suggest that important biomolecules related to cerebral microinfarction can be detected by ToF-SIMS.

  9. A Hierarchical Clustering Methodology for the Estimation of Toxicity

    EPA Science Inventory

    A Quantitative Structure Activity Relationship (QSAR) methodology based on hierarchical clustering was developed to predict toxicological endpoints. This methodology utilizes Ward's method to divide a training set into a series of structurally similar clusters. The structural sim...

  10. Look@NanoSIMS--a tool for the analysis of nanoSIMS data in environmental microbiology.

    PubMed

    Polerecky, Lubos; Adam, Birgit; Milucka, Jana; Musat, Niculina; Vagner, Tomas; Kuypers, Marcel M M

    2012-04-01

    We describe an open-source freeware programme for high throughput analysis of nanoSIMS (nanometre-scale secondary ion mass spectrometry) data. The programme implements basic data processing and analytical functions, including display and drift-corrected accumulation of scanned planes, interactive and semi-automated definition of regions of interest (ROIs), and export of the ROIs' elemental and isotopic composition in graphical and text-based formats. Additionally, the programme offers new functions that were custom-designed to address the needs of environmental microbiologists. Specifically, it allows manual and automated classification of ROIs based on the information that is derived either from the nanoSIMS dataset itself (e.g. from labelling achieved by halogen in situ hybridization) or is provided externally (e.g. as a fluorescence in situ hybridization image). Moreover, by implementing post-processing routines coupled to built-in statistical tools, the programme allows rapid synthesis and comparative analysis of results from many different datasets. After validation of the programme, we illustrate how these new processing and analytical functions increase flexibility, efficiency and depth of the nanoSIMS data analysis. Through its custom-made and open-source design, the programme provides an efficient, reliable and easily expandable tool that can help a growing community of environmental microbiologists and researchers from other disciplines process and analyse their nanoSIMS data. © 2012 Society for Applied Microbiology and Blackwell Publishing Ltd.

  11. Understanding the Changes to Biomass Surface Characteristics after Ammonia and Organosolv Pretreatments by Using Time-of-Flight Secondary-Ion Mass Spectrometry (TOF-SIMS)

    DOE PAGES

    Tolbert, Allison K.; Yoo, Chang Geun; Ragauskas, Arthur J.

    2017-03-20

    Surface characteristic changes to poplar after ammonia and organosolv pretreatments were investigated by means of time-of-flight secondary-ion mass spectrometry (TOF-SIMS) analysis. Whereas normalized total polysaccharides and lignin contents on the surface differed from bulk chemical compositions, the surface cellulose ions detected by TOF-SIMS showed the same value trend as the cellulose content in the biomass. In addition, the lignin syringyl/guaiacyl ratio according to TOF-SIMS results showed the same trend as the ratio measured by means of NMR spectroscopic analysis, even though the ratio scales for each method were different. A similar correlation was determined between the surface cellulose and glucosemore » release after enzymatic hydrolysis. Lastly, these results demonstrate that surface characterization using TOF-SIMS can provide important information about the effects of pretreatment on biomass properties and its hydrolysis.« less

  12. Probing nanoparticles and nanoparticle-conjugated biomolecules using time-of-flight secondary ion mass spectrometry.

    PubMed

    Kim, Young-Pil; Shon, Hyun Kyong; Shin, Seung Koo; Lee, Tae Geol

    2015-01-01

    Bio-conjugated nanoparticles have emerged as novel molecular probes in nano-biotechnology and nanomedicine and chemical analyses of their surfaces have become challenges. The time-of-flight (TOF) secondary ion mass spectrometry (SIMS) has been one of the most powerful surface characterization techniques for both nanoparticles and biomolecules. When combined with various nanoparticle-based signal enhancing strategies, TOF-SIMS can probe the functionalization of nanoparticles as well as their locations and interactions in biological systems. Especially, nanoparticle-based SIMS is an attractive approach for label-free drug screening because signal-enhancing nanoparticles can be designed to directly measure the enzyme activity. The chemical-specific imaging analysis using SIMS is also well suited to screen nanoparticles and nanoparticle-biomolecule conjugates in complex environments. This review presents some recent applications of nanoparticle-based TOF-SIMS to the chemical analysis of complex biological systems. © 2014 Wiley Periodicals, Inc.

  13. Understanding the Changes to Biomass Surface Characteristics after Ammonia and Organosolv Pretreatments by Using Time-of-Flight Secondary-Ion Mass Spectrometry (TOF-SIMS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tolbert, Allison K.; Yoo, Chang Geun; Ragauskas, Arthur J.

    Surface characteristic changes to poplar after ammonia and organosolv pretreatments were investigated by means of time-of-flight secondary-ion mass spectrometry (TOF-SIMS) analysis. Whereas normalized total polysaccharides and lignin contents on the surface differed from bulk chemical compositions, the surface cellulose ions detected by TOF-SIMS showed the same value trend as the cellulose content in the biomass. In addition, the lignin syringyl/guaiacyl ratio according to TOF-SIMS results showed the same trend as the ratio measured by means of NMR spectroscopic analysis, even though the ratio scales for each method were different. A similar correlation was determined between the surface cellulose and glucosemore » release after enzymatic hydrolysis. Lastly, these results demonstrate that surface characterization using TOF-SIMS can provide important information about the effects of pretreatment on biomass properties and its hydrolysis.« less

  14. Soccer Injury Movement Screen (SIMS) Composite Score Is Not Associated With Injury Among Semi-Professional Soccer Players.

    PubMed

    McCunn, Robert; Fünten, Karen Aus der; Whalan, Matthew; Sampson, John A; Meyer, Tim

    2018-05-08

    Study Design Prospective cohort. Background The association between movement quality and injury is equivocal. No soccer-specific movement assessment has been prospectively investigated in relation to injury risk. Objectives To investigate the association between a soccer-specific movement quality assessment and injury risk among semi-professional soccer players. Methods Semi-professional soccer players (n=306) from 12 clubs completed the Soccer Injury Movement Screen (SIMS) during the pre-season period. Individual training/match exposure and non-contact time loss injuries were recorded prospectively for the entirety of the 2016 season. Relative risks (RR) were calculated, and presented with 90% confidence intervals (CI), for the SIMS composite and individual sub-test scores from generalized linear models with Poisson distribution offset for exposure. Results When considering non-contact time loss lower extremity injuries (primary level of analysis), there was a most likely trivial association with the SIMS composite score. Similarly, SIMS composite score demonstrated most likely to likely trivial associations to all injury categories included in the secondary level of analysis (non-contact time loss hip/groin, thigh, knee and ankle injuries). When considering hamstring strains and ankle sprains specifically (tertiary level of analysis) the SIMS composite score, again, demonstrated very likely trivial associations. A total of 262 non-contact time loss injuries were recorded. The overall (training and match exposure combined) incidence of non-contact time loss injury was 12/1000 hours. Conclusion The SIMS composite score demonstrated no association to any of the investigated categories of soccer-related injury. The SIMS composite score should not be used to group players into 'high' or 'low' risk groups. Level of Evidence Prognosis, level 4. J Orthop Sports Phys Ther, Epub 8 May 2018. doi:10.2519/jospt.2018.8037.

  15. SimExTargId: A comprehensive package for real-time LC-MS data acquisition and analysis.

    PubMed

    Edmands, William M B; Hayes, Josie; Rappaport, Stephen M

    2018-05-22

    Liquid chromatography mass spectrometry (LC-MS) is the favored method for untargeted metabolomic analysis of small molecules in biofluids. Here we present SimExTargId, an open-source R package for autonomous analysis of metabolomic data and real-time observation of experimental runs. This simultaneous, fully automated and multi-threaded (optional) package is a wrapper for vendor-independent format conversion (ProteoWizard), xcms- and CAMERA- based peak-picking, MetMSLine-based pre-processing and covariate-based statistical analysis. Users are notified of detrimental instrument drift or errors by email. Also included are two shiny applications, targetId for real-time MS2 target identification, and peakMonitor to monitor targeted metabolites. SimExTargId is publicly available under GNU LGPL v3.0 license at https://github.com/JosieLHayes/simExTargId, which includes a vignette with example data. SimExTargId should be installed on a dedicated data-processing workstation or server that is networked to the LC-MS platform to facilitate MS1 profiling of metabolomic data. josie.hayes@berkeley.edu. Supplementary data are available at Bioinformatics online.

  16. SIMS prototype system 1 test results: Engineering analysis

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The space and domestic water solar heating system designated SIMS Prototype Systems 1 was evaluated. The test system used 720 ft (gross) of Solar Energy Products Air Collectors, a Solar Control Corporation SAM 20 Air Handler with Model 75-175 control unit, a Jackson Solar Storage tank with Rho Sigma Mod 106 controller, and 20 tons of rack storage. The test data analysis performed evaluates the system performance and documents the suitability of SIMS Prototype System 1 hardware for field installation.

  17. Advantages of TOF-SIMS analysis of hydroxyapatite and fluorapatite in comparison with XRD, HR-TEM and FT-IR.

    PubMed

    Okazaki, Masayuki; Hirata, Isao; Matsumoto, Takuya; Takahashi, Junzo

    2005-12-01

    The chemical analysis of hydroxyapatite and fluorapatite was carried out using time-of-flight secondary ion mass spectrometry (TOF-SIMS). Hydroxyapatite and fluorapatite were synthesized at 80 +/- 1 degrees C and pH 7.4 +/- 0.2. Fluorapatite was better crystallized, with its (300) reflection shifted to a slightly higher angle. High-resolution transmission electron microscopy clearly revealed a typical, regular hexagonal cross section perpendicular to the c-axis for fluorapatite and a flattened hexagonal cross section for hydroxyapatite. FT-IR spectra of fluorapatite confirmed the absence of OH absorption peak--which was seen in hydroxyapatite at about 3570 cm(-1). TOF-SIMS mass spectra showed a peak at 40 amu due to calcium. In addition, a peak at 19 amu due to fluorine could be clearly seen, although the intensities of PO, PO2, and PO3 were very low. It was confirmed that TOF-SIMS clearly showed the differences between positive and negative mass spectra of hydroxyapatite and fluorapatite, especially for F-. We concluded that TOF-SIMS exhibited distinct advantages compared with other methods of analysis.

  18. WholeCellSimDB: a hybrid relational/HDF database for whole-cell model predictions.

    PubMed

    Karr, Jonathan R; Phillips, Nolan C; Covert, Markus W

    2014-01-01

    Mechanistic 'whole-cell' models are needed to develop a complete understanding of cell physiology. However, extracting biological insights from whole-cell models requires running and analyzing large numbers of simulations. We developed WholeCellSimDB, a database for organizing whole-cell simulations. WholeCellSimDB was designed to enable researchers to search simulation metadata to identify simulations for further analysis, and quickly slice and aggregate simulation results data. In addition, WholeCellSimDB enables users to share simulations with the broader research community. The database uses a hybrid relational/hierarchical data format architecture to efficiently store and retrieve both simulation setup metadata and results data. WholeCellSimDB provides a graphical Web-based interface to search, browse, plot and export simulations; a JavaScript Object Notation (JSON) Web service to retrieve data for Web-based visualizations; a command-line interface to deposit simulations; and a Python API to retrieve data for advanced analysis. Overall, we believe WholeCellSimDB will help researchers use whole-cell models to advance basic biological science and bioengineering. http://www.wholecellsimdb.org SOURCE CODE REPOSITORY: URL: http://github.com/CovertLab/WholeCellSimDB. © The Author(s) 2014. Published by Oxford University Press.

  19. Super-resolution microscopy as a potential approach to diagnosis of platelet granule disorders.

    PubMed

    Westmoreland, D; Shaw, M; Grimes, W; Metcalf, D J; Burden, J J; Gomez, K; Knight, A E; Cutler, D F

    2016-04-01

    Many platelet functions are dependent on bioactive molecules released from their granules. Deficiencies of these granules in number, shape or content are associated with bleeding. The small size of these granules is such that imaging them for diagnosis has traditionally required electron microscopy. However, recently developed super-resolution microscopes provide sufficient spatial resolution to effectively image platelet granules. When combined with automated image analysis, these methods provide a quantitative, unbiased, rapidly acquired dataset that can readily and reliably reveal differences in platelet granules between individuals. To demonstrate the ability of structured illumination microscopy (SIM) to efficiently differentiate between healthy volunteers and three patients with Hermansky-Pudlak syndrome. Blood samples were taken from three patients with Hermansky-Pudlak syndrome and seven controls. Patients 1-3 have gene defects in HPS1, HPS6 and HPS5, respectively; all controls were healthy volunteers. Platelet-rich plasma was isolated from blood and the platelets fixed, stained for CD63 and processed for analysis by immunofluorescence microscopy, using a custom-built SIM microscope. SIM can successfully resolve CD63-positive structures in fixed platelets. A determination of the number of CD63-positive structures per platelet allowed us to conclude that each patient was significantly different from all of the controls with 99% confidence. A super-resolution imaging approach is effective and rapid in objectively differentiating between patients with a platelet bleeding disorder and healthy volunteers. CD63 is a useful marker for predicting Hermansky-Pudlak syndrome and could be used in the diagnosis of patients suspected of other platelet granule disorders. © 2016 The Authors. Journal of Thrombosis and Haemostasis published by Wiley Periodicals, Inc. on behalf of International Society on Thrombosis and Haemostasis.

  20. The Determination of Remaining Satellite Propellant Using Measured Moments of Inertia

    DTIC Science & Technology

    2006-06-01

    Simulated Satellite (SimSat) were developed. These models were created using dynamic response analysis techniques on the reaction wheel and SimSat systems...Flowchart ......................................................... 5 Figure 2. Air Force Institute of Technology’s Simulated Satellite (SimSat...Determining Change in Satellite Fuel ............................... 88 xiv List of Symbols and Abbreviations ai Acceleration of a particle

  1. SIMS prototype system 3 test results: Engineering analysis

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The results obtained during testing of a closed hydronic drain down solar system designed for space and hot water heating is presented. Data analysis is included which documents the system performance and verifies the suitability of SIMS Prototype System 3 for field installation.

  2. Direct surface analysis of pesticides on soil, leaves, grass, and stainless steel by static secondary ion mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ingram, J.C.; Groenewold, G.S.; Appelhans, A.D.

    1997-02-01

    Direct surface analyses by static secondary ion mass spectrometry (SIMS) were performed for the following pesticides adsorbed on dandelion leaves, grass, soil, and stainless steel samples: alachlor, atrazine, captan, carbofuran, chlorpyrifos, chlorosulfuron, chlorthal-dimethyl, cypermethrin, 2,4-D, diuron, glyphosate, malathion, methomyl, methyl arsonic acid, mocap, norflurazon, oxyfluorfen, paraquat, temik, and trifluralin. The purpose of this study was to evaluate static SIMS as a tool for pesticide analysis, principally for use in screening samples for pesticides. The advantage of direct surface analysis compared with conventional pesticide analysis methods is the elimination of sample pretreatment including extraction, which streamlines the analysis substantially; total analysismore » time for SIMS analysis was ca. 10 min/sample. Detection of 16 of the 20 pesticides on all four substrates was achieved. Of the remaining four pesticides, only one (trifluralin) was not detected on any of the samples. The minimum detectable quantity was determined for paraquat on soil in order to evaluate the efficacy of using SIMS as a screening tool. Paraquat was detected at 3 pg/mm{sup 2} (c.a. 0.005 monolayers). The results of these studies suggest that SIMS is capable of direct surface detection of a range of pesticides, with low volatility, polar pesticides being the most easily detected. 25 refs., 2 figs., 2 tabs.« less

  3. MI-Sim: A MATLAB package for the numerical analysis of microbial ecological interactions.

    PubMed

    Wade, Matthew J; Oakley, Jordan; Harbisher, Sophie; Parker, Nicholas G; Dolfing, Jan

    2017-01-01

    Food-webs and other classes of ecological network motifs, are a means of describing feeding relationships between consumers and producers in an ecosystem. They have application across scales where they differ only in the underlying characteristics of the organisms and substrates describing the system. Mathematical modelling, using mechanistic approaches to describe the dynamic behaviour and properties of the system through sets of ordinary differential equations, has been used extensively in ecology. Models allow simulation of the dynamics of the various motifs and their numerical analysis provides a greater understanding of the interplay between the system components and their intrinsic properties. We have developed the MI-Sim software for use with MATLAB to allow a rigorous and rapid numerical analysis of several common ecological motifs. MI-Sim contains a series of the most commonly used motifs such as cooperation, competition and predation. It does not require detailed knowledge of mathematical analytical techniques and is offered as a single graphical user interface containing all input and output options. The tools available in the current version of MI-Sim include model simulation, steady-state existence and stability analysis, and basin of attraction analysis. The software includes seven ecological interaction motifs and seven growth function models. Unlike other system analysis tools, MI-Sim is designed as a simple and user-friendly tool specific to ecological population type models, allowing for rapid assessment of their dynamical and behavioural properties.

  4. Detection of Fatty Acids from Intact Microorganisms by Molecular Beam Static Secondary Ion Mass Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ingram, Jani Cheri; Lehman, Richard Michael; Bauer, William Francis

    We report the use of a surface analysis approach, static secondary ion mass spectrometry (SIMS) equipped with a molecular (ReO4-) ion primary beam, to analyze the surface of intact microbial cells. SIMS spectra of 28 microorganisms were compared to fatty acid profiles determined by gas chromatographic analysis of transesterfied fatty acids extracted from the same organisms. The results indicate that surface bombardment using the molecular primary beam cleaved the ester linkage characteristic of bacteria at the glycerophosphate backbone of the phospholipid components of the cell membrane. This cleavage enables direct detection of the fatty acid conjugate base of intact microorganismsmore » by static SIMS. The limit of detection for this approach is approximately 107 bacterial cells/cm2. Multivariate statistical methods were applied in a graded approach to the SIMS microbial data. The results showed that the full data set could initially be statistically grouped based upon major differences in biochemical composition of the cell wall. The gram-positive bacteria were further statistically analyzed, followed by final analysis of a specific bacterial genus that was successfully grouped by species. Additionally, the use of SIMS to detect microbes on mineral surfaces is demonstrated by an analysis of Shewanella oneidensis on crushed hematite. The results of this study provide evidence for the potential of static SIMS to rapidly detect bacterial species based on ion fragments originating from cell membrane lipids directly from sample surfaces.« less

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Jiachao; Zhou, Yufan; Hua, Xin

    We demonstrate in situ chemical imaging of protein biomolecules in the aqueous solution using System for Analysis at the Liquid Vacuum Interface (SALVI) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The fibronectin protein film was immobilized on the silicon nitride (SiN) membrane forming the SALVI detection area. During ToF-SIMS analysis, three modes of analysis were conducted including high spatial resolution mass spectra, two-dimensional (2D) imaging, and depth profiling. Mass spectra were acquired in both positive and negative modes. Deionized water was also analyzed as a reference sample. Our results show that fibronectin film in water has more distinct and strongermore » water cluster peaks compared to water alone. Characteristic peaks of amino acid fragments are also observable in the hydrated protein ToF-SIMS spectra. These results illustrate that protein molecule adsorption on a surface can be studied dynamically using SALVI and ToF-SIMS in the liquid environment.« less

  6. Investigation of the Ionization Mechanism of NAD+/NADH-Modified Gold Electrodes in ToF-SIMS Analysis.

    PubMed

    Hua, Xin; Zhao, Li-Jun; Long, Yi-Tao

    2018-06-04

    Analysis of nicotinamide adenine dinucleotide (NAD + /NADH)-modified electrodes is important for in vitro monitoring of key biological processes. In this work, time-of-flight secondary ion mass spectrometry (ToF-SIMS) was used to analyze NAD + /NADH-modified gold electrodes. Interestingly, no obvious characteristic peaks of nicotinamide fragment could be observed in the mass spectra of NAD + /NADH in their neutral sodium pyrophosphate form. However, after acidification, the characteristic peaks for both NAD + and NADH were detected. This was due to the suppression effect of inner pyrophosphoric salts in both neutral molecules. Besides, it was proved that the suppression by inner salt was intramolecular. No obvious suppression was found between neighboring molecules. These results demonstrated the suppression effect of inner salts in ToF-SIMS analysis, providing useful evidence for the study of ToF-SIMS ionization mechanism of organic molecule-modified electrodes. Graphical Abstract ᅟ.

  7. Development of quantitative laser ionization mass spectrometry (LIMS). Final report, 1 Aug 87-1 Jan 90

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Odom, R.W.

    1991-06-04

    The objective of the research was to develop quantitative microanalysis methods for dielectric thin films using the laser ionization mass spectrometry (LIMS) technique. The research involved preparation of thin (5,000 A) films of SiO2, Al2O3, MgF2, TiO2, Cr2O3, Ta2O5, Si3N4, and ZrO2, and doping these films with ion implant impurities of 11B, 40Ca, 56Fe, 68Zn, 81Br, and 121Sb. Laser ionization mass spectrometry (LIMS), secondary ion mass spectrometry (SIMS) and Rutherford backscattering spectrometry (RBS) were performed on these films. The research demonstrated quantitative LIMS analysis down to detection levels of 10-100 ppm, and led to the development of (1) a compoundmore » thin film standards product line for the performing organization, (2) routine LIMS analytical methods, and (3) the manufacture of high speed preamplifiers for time-of-flight mass spectrometry (TOF-MS) techniques.« less

  8. Poly-Small Ubiquitin-like Modifier (PolySUMO)-binding Proteins Identified through a String Search*

    PubMed Central

    Sun, Huaiyu; Hunter, Tony

    2012-01-01

    Polysumoylation is a crucial cellular response to stresses against genomic integrity or proteostasis. Like the small ubiquitin-like modifier (SUMO)-targeted ubiquitin ligase RNF4, proteins with clustered SUMO-interacting motifs (SIMs) can be important signal transducers downstream of polysumoylation. To identify novel polySUMO-binding proteins, we conducted a computational string search with a custom Python script. We found clustered SIMs in another RING domain protein Arkadia/RNF111. Detailed biochemical analysis of the Arkadia SIMs revealed that dominant SIMs in a SIM cluster often contain a pentameric VIDLT ((V/I/L/F/Y)(V/I)DLT) core sequence that is also found in the SIMs in PIAS family E3s and is likely the best-fitted structure for SUMO recognition. This idea led to the identification of additional novel SIM clusters in FLASH/CASP8AP2, C5orf25, and SOBP/JXC1. We suggest that the clustered SIMs in these proteins form distinct SUMO binding domains to recognize diverse forms of protein sumoylation. PMID:23086935

  9. Modern Material Analysis Instruments Add a New Dimension to Materials Characterization and Failure Analysis

    NASA Technical Reports Server (NTRS)

    Panda, Binayak

    2009-01-01

    Modern analytical tools can yield invaluable results during materials characterization and failure analysis. Scanning electron microscopes (SEMs) provide significant analytical capabilities, including angstrom-level resolution. These systems can be equipped with a silicon drift detector (SDD) for very fast yet precise analytical mapping of phases, as well as electron back-scattered diffraction (EBSD) units to map grain orientations, chambers that admit large samples, variable pressure for wet samples, and quantitative analysis software to examine phases. Advanced solid-state electronics have also improved surface and bulk analysis instruments: Secondary ion mass spectroscopy (SIMS) can quantitatively determine and map light elements such as hydrogen, lithium, and boron - with their isotopes. Its high sensitivity detects impurities at parts per billion (ppb) levels. X-ray photo-electron spectroscopy (XPS) can determine oxidation states of elements, as well as identifying polymers and measuring film thicknesses on coated composites. This technique is also known as electron spectroscopy for chemical analysis (ESCA). Scanning Auger electron spectroscopy (SAM) combines surface sensitivity, spatial lateral resolution (10 nm), and depth profiling capabilities to describe elemental compositions of near and below surface regions down to the chemical state of an atom.

  10. Quantitative analysis of H2O and CO2 in cordierite using polarized FTIR spectroscopy

    NASA Astrophysics Data System (ADS)

    Della Ventura, Giancarlo; Radica, Francesco; Bellatreccia, Fabio; Cavallo, Andrea; Capitelli, Francesco; Harley, Simon

    2012-11-01

    We report a FTIR (Fourier transform infrared) study of a set of cordierite samples from different occurrence and with different H2O/CO2 content. The specimens were fully characterized by a combination of techniques including optical microscopy, single-crystal X-ray diffraction, EMPA (electron microprobe analysis), SIMS (secondary ion mass spectrometry), and FTIR spectroscopy. All cordierites are orthorhombic Ccmm. According to the EMPA data, the Si/Al ratio is always close to 5:4; X Mg ranges from 76.31 to 96.63, and additional octahedral constituents occur in very small amounts. Extraframework K and Ca are negligible, while Na reaches the values up to 0.84 apfu. SIMS shows H2O up to 1.52 and CO2 up to 1.11 wt%. Optically transparent single crystals were oriented using the spindle stage and examined by FTIR micro-spectroscopy under polarized light. On the basis of the polarizing behaviour, the observed bands were assigned to water molecules in two different orientations and to CO2 molecules in the structural channels. The IR spectra also show the presence of small amounts of CO in the samples. Refined integrated molar absorption coefficients were calibrated for the quantitative microanalysis of both H2O and CO2 in cordierite based on single-crystal polarized-light FTIR spectroscopy. For H2O the integrated molar coefficients for type I and type II water molecules (ν3 modes) were calculated separately and are [I]ɛ = 5,200 ± 700 l mol-1 cm-2 and [II]ɛ = 13,000 ± 3,000 l mol-1 cm-2, respectively. For CO2 the integrated coefficient is \\varepsilon_{{{{CO}}_{ 2} }} = 19,000 ± 2,000 l mol-1 cm-2.

  11. Application of ethyl esters and d3-methyl esters as internal standards for the gas chromatographic quantification of transesterified fatty acid methyl esters in food.

    PubMed

    Thurnhofer, Saskia; Vetter, Walter

    2006-05-03

    Ethyl esters (FAEE) and trideuterium-labeled methyl esters (d3-FAME) of fatty acids were prepared and investigated regarding their suitability as internal standards (IS) for the determination of fatty acids as methyl esters (FAME). On CP-Sil 88, ethyl esters of odd-numbered fatty acids eluted approximately 0.5 min after the respective FAME, and only coelutions with minor FAME were observed. Depending on the problem, one or even many FAEE can be added as IS for the quantification of FAME by both GC-FID and GC-MS. By contrast, d3-FAME coeluted with FAME on the polar GC column, and the use of the former as IS requires application of GC-MS. In the SIM mode, m/z 77 and 90 are suggested for d3-methyl esters of saturated fatty acids, whereas m/z 88 and 101 are recommended for ethyl esters of saturated fatty acids. These m/z values give either no or very low response for FAME and can thus be used for the analysis of FAME in food by GC-MS in the SIM mode. Fatty acids in sunflower oil and mozzarella cheese were quantified using five saturated FAEE as IS. Gravimetric studies showed that the transesterification procedure could be carried out without of loss of fatty acids. GC-EI/MS full scan analysis was suitable for the quantitative determination of all unsaturated fatty acids in both food samples, whereas GC-EI/MS in the SIM mode was particularly valuable for quantifying minor fatty acids. The novel GC-EI/MS/SIM method using fatty acid ethyl esters as internal standards can be used to quantify individual fatty acids only, that is, without determination of all fatty acids (the common 100% method), although this is present. This was demonstrated by the exclusive quantification of selected fatty acids including methyl-branched fatty acids, erucic acid (18:1n-9trans), and polyunsaturated fatty acids in cod liver oil and goat's milk fat.

  12. Surface characterization of dialyzer polymer membranes by imaging ToF-SIMS and quantitative XPS line scans.

    PubMed

    Holzweber, Markus; Lippitz, Andreas; Krueger, Katharina; Jankowski, Joachim; Unger, Wolfgang E S

    2015-03-24

    The surfaces of polymeric dialyzer membranes consisting of polysulfone and polyvinylpyrrolidone were investigated regarding the lateral distribution and quantitative surface composition using time-of-flight secondary-ion-mass-spectrometry and x-ray photoelectron spectroscopy. Knowledge of the distribution and composition on the outer surface region is of utmost importance for understanding the biocompatibility of such dialyzer membranes. Both flat membranes and hollow fiber membranes were studied.

  13. Identification of the Key Genes and Pathways in Esophageal Carcinoma.

    PubMed

    Su, Peng; Wen, Shiwang; Zhang, Yuefeng; Li, Yong; Xu, Yanzhao; Zhu, Yonggang; Lv, Huilai; Zhang, Fan; Wang, Mingbo; Tian, Ziqiang

    2016-01-01

    Objective . Esophageal carcinoma (EC) is a frequently common malignancy of gastrointestinal cancer in the world. This study aims to screen key genes and pathways in EC and elucidate the mechanism of it. Methods . 5 microarray datasets of EC were downloaded from Gene Expression Omnibus. Differentially expressed genes (DEGs) were screened by bioinformatics analysis. Gene Ontology (GO) enrichment, Kyoto Encyclopedia of Genes and Genomes (KEGG) enrichment, and protein-protein interaction (PPI) network construction were performed to obtain the biological roles of DEGs in EC. Quantitative real-time polymerase chain reaction (qRT-PCR) was used to verify the expression level of DEGs in EC. Results . A total of 1955 genes were filtered as DEGs in EC. The upregulated genes were significantly enriched in cell cycle and the downregulated genes significantly enriched in Endocytosis. PPI network displayed CDK4 and CCT3 were hub proteins in the network. The expression level of 8 dysregulated DEGs including CDK4, CCT3, THSD4, SIM2, MYBL2, CENPF, CDCA3, and CDKN3 was validated in EC compared to adjacent nontumor tissues and the results were matched with the microarray analysis. Conclusion . The significantly DEGs including CDK4, CCT3, THSD4, and SIM2 may play key roles in tumorigenesis and development of EC involved in cell cycle and Endocytosis.

  14. Chemical Visualization of Sweat Pores in Fingerprints Using GO-Enhanced TOF-SIMS.

    PubMed

    Cai, Lesi; Xia, Meng-Chan; Wang, Zhaoying; Zhao, Ya-Bin; Li, Zhanping; Zhang, Sichun; Zhang, Xinrong

    2017-08-15

    Time-of-flight secondary ion mass spectrometry (TOF-SIMS) has been used in imaging of small molecules (<500 Da) in fingerprints, such as gunshot residues and illicit drugs. However, identifying and mapping relatively high mass molecules are quite difficult owing to insufficient ion yield of their molecular ions. In this report, graphene oxide (GO)-enhanced TOF-SIMS was used to detect and image relatively high mass molecules such as poison, alkaloids (>600 Da) and controlled drugs, and antibiotics (>700 Da) in fingerprints. Detail features of fingerprints such as the number and distribution of sweat pores in a ridge and even the delicate morphology of one pore were clearly revealed in SIMS images of relatively high mass molecules. The detail features combining with identified chemical composition were sufficient to establish a human identity and link the suspect to a crime scene. The wide detectable mass range and high spatial resolution make GO-enhanced TOF-SIMS a promising tool in accurate and fast analysis of fingerprints, especially in fragmental fingerprint analysis.

  15. Chemical determination of free radical-induced damage to DNA.

    PubMed

    Dizdaroglu, M

    1991-01-01

    Free radical-induced damage to DNA in vivo can result in deleterious biological consequences such as the initiation and promotion of cancer. Chemical characterization and quantitation of such DNA damage is essential for an understanding of its biological consequences and cellular repair. Methodologies incorporating the technique of gas chromatography/mass spectrometry (GC/MS) have been developed in recent years for measurement of free radical-induced DNA damage. The use of GC/MS with selected-ion monitoring (SIM) facilitates unequivocal identification and quantitation of a large number of products of all four DNA bases produced in DNA by reactions with hydroxyl radical, hydrated electron, and H atom. Hydroxyl radical-induced DNA-protein cross-links in mammalian chromatin, and products of the sugar moiety in DNA are also unequivocally identified and quantitated. The sensitivity and selectivity of the GC/MS-SIM technique enables the measurement of DNA base products even in isolated mammalian chromatin without the necessity of first isolating DNA, and despite the presence of histones. Recent results reviewed in this article demonstrate the usefulness of the GC/MS technique for chemical determination of free radical-induced DNA damage in DNA as well as in mammalian chromatin under a vast variety of conditions of free radical production.

  16. Reprint Of: Enhanced spatially-resolved trace analysis using combined SIMS-single-stage AMS

    NASA Astrophysics Data System (ADS)

    Grabowski, K. S.; Groopman, E. E.; Fahey, A. J.

    2018-01-01

    Secondary ion mass spectrometry (SIMS) provides spatially resolved trace analysis of solid materials, but can be complicated by unresolved abundant molecular isobars. By adding a 300-kV single-stage accelerator mass spectrometer (SSAMS) as a detector for a Cameca ims 4f SIMS, one can measure more abundant positive ions from the SIMS while removing molecular isobars, thus improving very low abundance trace element and isotope analysis. This paper describes important features and capabilities of such an integrated system at the Naval Research Laboratory using charge state +1 ions. Transmission loss is compared to molecule destruction as gas flow to the molecule-destruction cell increases. As most measurements tolerate more modest abundance sensitivities than for 14C analysis, a lower gas flow is acceptable, so good transmission of 20-50% for ions of interest can be maintained for a broad range of ion masses. This new instrument has measured isotope ratios for uranium, lead, rare earths, and other elements from particulates and localized regions, with molecule destruction enabling the measurement at low SIMS mass resolving power and thus high transmission, as examples will show. This new and world-unique instrument provides improved capabilities for applications in nuclear and other forensics, geochemistry, cosmochemistry, and the development of optical, electronic, multifunctional, and structural materials.

  17. Enhanced spatially-resolved trace analysis using combined SIMS-single-stage AMS

    NASA Astrophysics Data System (ADS)

    Grabowski, K. S.; Groopman, E. E.; Fahey, A. J.

    2017-11-01

    Secondary ion mass spectrometry (SIMS) provides spatially resolved trace analysis of solid materials, but can be complicated by unresolved abundant molecular isobars. By adding a 300-kV single-stage accelerator mass spectrometer (SSAMS) as a detector for a Cameca ims 4f SIMS, one can measure more abundant positive ions from the SIMS while removing molecular isobars, thus improving very low abundance trace element and isotope analysis. This paper describes important features and capabilities of such an integrated system at the Naval Research Laboratory using charge state +1 ions. Transmission loss is compared to molecule destruction as gas flow to the molecule-destruction cell increases. As most measurements tolerate more modest abundance sensitivities than for 14C analysis, a lower gas flow is acceptable, so good transmission of 20-50% for ions of interest can be maintained for a broad range of ion masses. This new instrument has measured isotope ratios for uranium, lead, rare earths, and other elements from particulates and localized regions, with molecule destruction enabling the measurement at low SIMS mass resolving power and thus high transmission, as examples will show. This new and world-unique instrument provides improved capabilities for applications in nuclear and other forensics, geochemistry, cosmochemistry, and the development of optical, electronic, multifunctional, and structural materials.

  18. ToF-SIMS observation for evaluating the interaction between amyloid β and lipid membranes.

    PubMed

    Aoyagi, Satoka; Shimanouchi, Toshinori; Kawashima, Tomoko; Iwai, Hideo

    2015-04-01

    The adsorption behaviour of amyloid beta (Aβ), thought to be a key peptide for understanding Alzheimer's disease, was investigated by means of time-of-flight secondary ion mass spectrometry (ToF-SIMS). Aβ aggregates depending on the lipid membrane condition though it has not been fully understood yet. In this study, Aβ samples on different lipid membranes, 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC), 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC) and 1,2-dioleoyl-sn-glycero-3-phosphocholine (DOPC), were observed with ToF-SIMS and the complex ToF-SIMS data of the Aβ samples was interpreted using data analysis techniques such as principal component analysis (PCA), gentle-SIMS (G-SIMS) and g-ogram. DOPC and DMPC are liquid crystal at room temperature, while DPPC is gel at room temperature. As primary ion beams, Bi3(+) and Ar cluster ion beams were used and the effect of an Ar cluster ion for evaluating biomolecules was also studied. The secondary ion images of the peptide fragment ions indicated by G-SIMS and g-ogram were consistent with the PCA results. It is suggested that Aβ is adsorbed homogeneously on the liquid-crystalline-phase lipid membranes, while it aggregates along the lipid on the gel-phase lipid membrane. Moreover, in the results using the Ar cluster, the influence of contamination was reduced.

  19. Effect of Simvastatin Prodrug on Experimental Periodontitis.

    PubMed

    Bradley, Aaron D; Zhang, Yijia; Jia, Zhenshan; Zhao, Gang; Wang, Xiaobei; Pranke, Laura; Schmid, Marian J; Wang, Dong; Reinhardt, Richard A

    2016-05-01

    Local application of statins has shown potential in preventing and regenerating bone loss associated with experimental periodontitis. This study evaluates the effect of a novel simvastatin (SIM) prodrug (capable of delivering high doses to periodontitis inflammatory lesion and cells) on experimental periodontitis bone loss and inflammation. Forty mature female Sprague Dawley rats were subjected to ligature-induced experimental periodontitis between maxillary first and second molars (M1-M2). Equal groups were treated with three weekly doses of: 1) prodrug carrier alone (mPEG); 2) 0.5 mg SIM dose equivalent in carrier (SIM/SIM-mPEG); 3) 1.0 mg SIM/SIM-mPEG; 4) 1.5 mg SIM/SIM-mPEG; or 5) ligature alone. Contralateral molars served as unmanipulated controls. Four weeks after initiation of periodontitis, animals were euthanized, the M1-M2 interproximal was evaluated with microcomputed tomography and histology, and data were analyzed with one-way analysis of variance. Ligature alone caused a mean bone loss of 1.01 ± 0.06 mm from the cemento-enamel junction, whereas all doses of SIM/SIM-mPEG reduced bone loss, especially 1.5 mg SIM/SIM-mPEG (0.68 ± 0.05 mm, P <0.001), which was not statistically different from contralateral control (0.47 ± 0.06 mm). A dose of 1.5 mg SIM/SIM-mPEG also reduced percentage of neutrophils compared with carrier alone (2.0% ± 1.0% versus 5.7% ± 1.1%; P <0.05), and increased amount of uninflamed connective tissue in the M1-M2 interproximal area (65.2% ± 3.3% versus 46.3% ± 3.3%; P <0.001). The mPEG carrier alone did not have bone-sparing or anti-inflammatory properties. Multiple local 1.5-mg doses of a macromolecular SIM prodrug decreases amount of experimental periodontitis bone loss and inflammation in rats.

  20. simBio: a Java package for the development of detailed cell models.

    PubMed

    Sarai, Nobuaki; Matsuoka, Satoshi; Noma, Akinori

    2006-01-01

    Quantitative dynamic computer models, which integrate a variety of molecular functions into a cell model, provide a powerful tool to create and test working hypotheses. We have developed a new modeling tool, the simBio package (freely available from ), which can be used for constructing cell models, such as cardiac cells (the Kyoto model from Matsuoka et al., 2003, 2004 a, b, the LRd model from Faber and Rudy, 2000, and the Noble 98 model from Noble et al., 1998), epithelial cells (Strieter et al., 1990) and pancreatic beta cells (Magnus and Keizer, 1998). The simBio package is written in Java, uses XML and can solve ordinary differential equations. In an attempt to mimic biological functional structures, a cell model is, in simBio, composed of independent functional modules called Reactors, such as ion channels and the sarcoplasmic reticulum, and dynamic variables called Nodes, such as ion concentrations. The interactions between Reactors and Nodes are described by the graph theory and the resulting graph represents a blueprint of an intricate cellular system. Reactors are prepared in a hierarchical order, in analogy to the biological classification. Each Reactor can be composed or improved independently, and can easily be reused for different models. This way of building models, through the combination of various modules, is enabled through the use of object-oriented programming concepts. Thus, simBio is a straightforward system for the creation of a variety of cell models on a common database of functional modules.

  1. [Determination of acetanilide herbicide residues in tea by gas chromatography-mass spectrometry with two different ionization techniques].

    PubMed

    Shen, Weijian; Xu, Jinzhong; Yang, Wenquan; Shen, Chongyu; Zhao, Zengyun; Ding, Tao; Wu, Bin

    2007-09-01

    An analytical method of solid phase extraction-gas chromatography-mass spectrometry with two different ionization techniques was established for simultaneous determination of 12 acetanilide herbicide residues in tea-leaves. Herbicides were extracted from tea-leaf samples with ethyl acetate. The extract was cleaned-up on an active carbon SPE column connected to a Florisil SPE column. Analytical screening was determined by the technique of gas chromatography (GC)-mass spectrometry (MS) in the selected ion monitoring (SIM) mode with either electron impact ionization (EI) or negative chemical ionization (NCI). It is reliable and stable that the recoveries of all herbicides were in the range from 50% to 110% at three spiked levels, 10 microg/kg, 20 microg/kg and 40 microg/kg, and the relative standard deviations (RSDs) were no more than 10.9%. The two different ionization techniques are complementary as more ion fragmentation information can be obtained from the EI mode while more molecular ion information from the NCI mode. By comparison of the two techniques, the selectivity of NCI-SIM was much better than that of EI-SIM method. The sensitivities of the both techniques were high, the limit of quantitative (LOQ) for each herbicide was no more than 2.0 microg/kg, and the limit of detection (LOD) with NCI-SIM technique was much lower than that of EI-SIM when analyzing herbicides with several halogen atoms in the molecule.

  2. Combined TEM and NanoSIMS Analysis of Subgrains in a SiC AB Grain

    NASA Astrophysics Data System (ADS)

    Hynes, K. M.; Amari, S.; Bernatowicz, T. J.; Lebsack, E.; Gyngard, F.; Nittler, L. R.

    2011-03-01

    We report the results of NanoSIMS and TEM analysis, including isotopic, structural, chemical, and subgrain data, on a SiC AB grain. This grain contains the first oldhamite subgrains observed in a presolar grain, as well as TiC- and Fe-rich subgrains.

  3. Model Package Report: Hanford Soil Inventory Model SIM v.2 Build 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nichols, Will E.; Zaher, U.; Mehta, S.

    The Hanford Soil Inventory Model (SIM) is a tool for the estimation of inventory of contaminants that were released to soil from liquid discharges during the U.S. Department of Energy’s Hanford Site operations. This model package report documents the construction and development of a second version of SIM (SIM-v2) to support the needs of Hanford Site Composite Analysis. The SIM-v2 is implemented using GoldSim Pro®1 software with a new model architecture that preserves the uncertainty in inventory estimates while reducing the computational burden (compared to the previous version) and allowing more traceability and transparency in calculation methodology. The calculation architecturemore » is designed in such a manner that future updates to the waste stream composition along with addition or deletion of waste sites can be performed with relative ease. In addition, the new computational platform allows for continued hardware upgrade.« less

  4. Analysis of specific RNA in cultured cells through quantitative integration of q-PCR and N-SIM single cell FISH images: Application to hormonal stimulation of StAR transcription.

    PubMed

    Lee, Jinwoo; Foong, Yee Hoon; Musaitif, Ibrahim; Tong, Tiegang; Jefcoate, Colin

    2016-07-05

    The steroidogenic acute regulatory protein (StAR) has been proposed to serve as the switch that can turn on/off steroidogenesis. We investigated the events that facilitate dynamic StAR transcription in response to cAMP stimulation in MA-10 Leydig cells, focusing on splicing anomalies at StAR gene loci. We used 3' reverse primers in a single reaction to respectively quantify StAR primary (p-RNA), spliced (sp-RNA/mRNA), and extended 3' untranslated region (UTR) transcripts, which were quantitatively imaged by high-resolution fluorescence in situ hybridization (FISH). This approach delivers spatio-temporal resolution of initiation and splicing at single StAR loci, and transfers individual mRNA molecules to cytoplasmic sites. Gene expression was biphasic, initially showing slow splicing, transitioning to concerted splicing. The alternative 3.5-kb mRNAs were distinguished through the use of extended 3'UTR probes, which exhibited distinctive mitochondrial distribution. Combining quantitative PCR and FISH enables imaging of localization of RNA expression and analysis of RNA processing rates. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Comparative assessment of bone pose estimation using Point Cluster Technique and OpenSim.

    PubMed

    Lathrop, Rebecca L; Chaudhari, Ajit M W; Siston, Robert A

    2011-11-01

    Estimating the position of the bones from optical motion capture data is a challenge associated with human movement analysis. Bone pose estimation techniques such as the Point Cluster Technique (PCT) and simulations of movement through software packages such as OpenSim are used to minimize soft tissue artifact and estimate skeletal position; however, using different methods for analysis may produce differing kinematic results which could lead to differences in clinical interpretation such as a misclassification of normal or pathological gait. This study evaluated the differences present in knee joint kinematics as a result of calculating joint angles using various techniques. We calculated knee joint kinematics from experimental gait data using the standard PCT, the least squares approach in OpenSim applied to experimental marker data, and the least squares approach in OpenSim applied to the results of the PCT algorithm. Maximum and resultant RMS differences in knee angles were calculated between all techniques. We observed differences in flexion/extension, varus/valgus, and internal/external rotation angles between all approaches. The largest differences were between the PCT results and all results calculated using OpenSim. The RMS differences averaged nearly 5° for flexion/extension angles with maximum differences exceeding 15°. Average RMS differences were relatively small (< 1.08°) between results calculated within OpenSim, suggesting that the choice of marker weighting is not critical to the results of the least squares inverse kinematics calculations. The largest difference between techniques appeared to be a constant offset between the PCT and all OpenSim results, which may be due to differences in the definition of anatomical reference frames, scaling of musculoskeletal models, and/or placement of virtual markers within OpenSim. Different methods for data analysis can produce largely different kinematic results, which could lead to the misclassification of normal or pathological gait. Improved techniques to allow non-uniform scaling of generic models to more accurately reflect subject-specific bone geometries and anatomical reference frames may reduce differences between bone pose estimation techniques and allow for comparison across gait analysis platforms.

  6. SimGraph: A Flight Simulation Data Visualization Workstation

    NASA Technical Reports Server (NTRS)

    Kaplan, Joseph A.; Kenney, Patrick S.

    1997-01-01

    Today's modern flight simulation research produces vast amounts of time sensitive data, making a qualitative analysis of the data difficult while it remains in a numerical representation. Therefore, a method of merging related data together and presenting it to the user in a more comprehensible format is necessary. Simulation Graphics (SimGraph) is an object-oriented data visualization software package that presents simulation data in animated graphical displays for easy interpretation. Data produced from a flight simulation is presented by SimGraph in several different formats, including: 3-Dimensional Views, Cockpit Control Views, Heads-Up Displays, Strip Charts, and Status Indicators. SimGraph can accommodate the addition of new graphical displays to allow the software to be customized to each user s particular environment. A new display can be developed and added to SimGraph without having to design a new application, allowing the graphics programmer to focus on the development of the graphical display. The SimGraph framework can be reused for a wide variety of visualization tasks. Although it was created for the flight simulation facilities at NASA Langley Research Center, SimGraph can be reconfigured to almost any data visualization environment. This paper describes the capabilities and operations of SimGraph.

  7. Surface characterization of dialyzer polymer membranes by imaging ToF-SIMS and quantitative XPS line scans

    PubMed Central

    Holzweber, Markus; Lippitz, Andreas; Krueger, Katharina; Jankowski, Joachim; Unger, Wolfgang E. S.

    2015-01-01

    The surfaces of polymeric dialyzer membranes consisting of polysulfone and poly-vinylpyrrolidone were investigated regarding the lateral distribution and quantitative surface composition using time-of-flight secondary-ion-mass-spectrometry and x-ray photoelectron spectroscopy. Knowledge of the distribution and composition on the outer surface region is of utmost importance for understanding the biocompatibility of such dialyzer membranes. Both flat membranes and hollow fiber membranes were studied. PMID:25711334

  8. Towards practical time-of-flight secondary ion mass spectrometry lignocellulolytic enzyme assays

    PubMed Central

    2013-01-01

    Background Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) is a surface sensitive mass spectrometry technique with potential strengths as a method for detecting enzymatic activity on solid materials. In particular, ToF-SIMS has been applied to detect the enzymatic degradation of woody lignocellulose. Proof-of-principle experiments previously demonstrated the detection of both lignin-degrading and cellulose-degrading enzymes on solvent-extracted hardwood and softwood. However, these preliminary experiments suffered from low sample throughput and were restricted to samples which had been solvent-extracted in order to minimize the potential for mass interferences between low molecular weight extractive compounds and polymeric lignocellulose components. Results The present work introduces a new, higher-throughput method for processing powdered wood samples for ToF-SIMS, meanwhile exploring likely sources of sample contamination. Multivariate analysis (MVA) including Principal Component Analysis (PCA) and Multivariate Curve Resolution (MCR) was regularly used to check for sample contamination as well as to detect extractives and enzyme activity. New data also demonstrates successful ToF-SIMS analysis of unextracted samples, placing an emphasis on identifying the low-mass secondary ion peaks related to extractives, revealing how extractives change previously established peak ratios used to describe enzyme activity, and elucidating peak intensity patterns for better detection of cellulase activity in the presence of extractives. The sensitivity of ToF-SIMS to a range of cellulase doses is also shown, along with preliminary experiments augmenting the cellulase cocktail with other proteins. Conclusions These new procedures increase the throughput of sample preparation for ToF-SIMS analysis of lignocellulose and expand the applications of the method to include unextracted lignocellulose. These are important steps towards the practical use of ToF-SIMS as a tool to screen for changes in plant composition, whether the transformation of the lignocellulose is achieved through enzyme application, plant mutagenesis, or other treatments. PMID:24034438

  9. High-resolution high-sensitivity elemental imaging by secondary ion mass spectrometry: from traditional 2D and 3D imaging to correlative microscopy

    NASA Astrophysics Data System (ADS)

    Wirtz, T.; Philipp, P.; Audinot, J.-N.; Dowsett, D.; Eswara, S.

    2015-10-01

    Secondary ion mass spectrometry (SIMS) constitutes an extremely sensitive technique for imaging surfaces in 2D and 3D. Apart from its excellent sensitivity and high lateral resolution (50 nm on state-of-the-art SIMS instruments), advantages of SIMS include high dynamic range and the ability to differentiate between isotopes. This paper first reviews the underlying principles of SIMS as well as the performance and applications of 2D and 3D SIMS elemental imaging. The prospects for further improving the capabilities of SIMS imaging are discussed. The lateral resolution in SIMS imaging when using the microprobe mode is limited by (i) the ion probe size, which is dependent on the brightness of the primary ion source, the quality of the optics of the primary ion column and the electric fields in the near sample region used to extract secondary ions; (ii) the sensitivity of the analysis as a reasonable secondary ion signal, which must be detected from very tiny voxel sizes and thus from a very limited number of sputtered atoms; and (iii) the physical dimensions of the collision cascade determining the origin of the sputtered ions with respect to the impact site of the incident primary ion probe. One interesting prospect is the use of SIMS-based correlative microscopy. In this approach SIMS is combined with various high-resolution microscopy techniques, so that elemental/chemical information at the highest sensitivity can be obtained with SIMS, while excellent spatial resolution is provided by overlaying the SIMS images with high-resolution images obtained by these microscopy techniques. Examples of this approach are given by presenting in situ combinations of SIMS with transmission electron microscopy (TEM), helium ion microscopy (HIM) and scanning probe microscopy (SPM).

  10. Secondary Ion Mass Spectrometers (SIMS) for calcium isotope measurements as an application to biological samples

    NASA Astrophysics Data System (ADS)

    Craven, S. M.; Hoenigman, J. R.; Moddeman, W. E.

    1981-11-01

    The potential use of secondary ion mass spectroscopy (SIMS) to analyze biological samples for calcium isotopes is discussed. Comparison of UTI and Extranuclear based quadrupole systems is made on the basis of the analysis of CaO and calcium metal. The Extranuclear quadrupole based system is superior in resolution and sensitivity to the UTI system and is recommended. For determination of calcium isotopes to within an accuracy of a few percent a high resolution quadrupole, such as the Extranuclear, and signal averaging capability are required. Charge neutralization will be mandated for calcium oxide, calcium nitrate, or calcium oxalate. SIMS is not capable of the high precision and high accuracy results possible by thermal ionization methods, but where faster analysis is desirable with an accuracy of a few percent, SIMS is a viable alternative.

  11. Lipidomics as an important key for the identification of beer-spoilage bacteria.

    PubMed

    Řezanka, T; Matoulková, D; Benada, O; Sigler, K

    2015-06-01

    Electrospray ionization-tandem mass spectrometry (ESI-MS/MS) was used for characterizing intact plasmalogen phospholipid molecules in beer-spoilage bacteria. Identification of intact plasmalogens was carried out using collision-induced dissociation and the presence of suitable marker molecular species, both qualitative and quantitative, was determined in samples containing the anaerobic bacteria Megasphaera and Pectinatus. Using selected ion monitoring (SIM), this method had a limit of detection at 1 pg for the standard, i.e. 1-(1Z-octadecenyl)-2-oleoyl-sn-glycero-3-phosphoethanolamine and be linear in the range of four orders of magnitude from 2 pg to 20 ng. This technique was applied to intact plasmalogen extracts from the samples of contaminated and uncontaminated beer without derivatization and resulted in the identification of contamination of beer by Megasphaera and Pectinatus bacteria. The limit of detection was about 830 cells of anaerobic bacteria, i.e. bacteria containing natural cyclopropane plasmalogenes (c-p-19:0/15:0), which is the majority plasmalogen located in both Megasphaera and Pectinatus. The SIM ESI-MS method has been shown to be useful for the analysis of low concentration of plasmalogens in all biological samples, which were contaminated with anaerobic bacteria, e.g. juice, not only in beer. Significance and impact of the study: Electrospray ionization-tandem mass spectrometry (ESI-MS/MS) using collision-induced dissociation was used to characterize intact plasmalogen phospholipid molecules in beer-spoilage anaerobic bacteria Megasphaera and Pectinatus. Using selected ion monitoring (SIM), this method has a detection limit of 1 pg for the standard 1-(1Z-octadecenyl)-2-oleoyl-sn-glycero-3-phosphoethanolamine and is linear within four orders of magnitude (2 pg to 20 ng). The limit of detection was about 830 cells of bacteria containing natural cyclopropane plasmalogen (c-p-19:0/15:0). SIM ESI-MS method is useful for analyzing low concentrations of plasmalogens in biological samples contaminated with anaerobic bacteria, e.g. beer or juice. © 2015 The Society for Applied Microbiology.

  12. Calibration and performance of synchronous SIM/scan mode for simultaneous targeted and discovery (non-targeted) analysis of exhaled breath samples from firefighters

    EPA Science Inventory

    Traditionally, gas chromatography – mass spectrometry (GC-MS) analysis has used a targeted approach called selected ion monitoring (SIM) to quantify specific compounds that may have adverse health effects. Due to method limitations and the constraints of preparing duplicat...

  13. Prediction and Validation of Disease Genes Using HeteSim Scores.

    PubMed

    Zeng, Xiangxiang; Liao, Yuanlu; Liu, Yuansheng; Zou, Quan

    2017-01-01

    Deciphering the gene disease association is an important goal in biomedical research. In this paper, we use a novel relevance measure, called HeteSim, to prioritize candidate disease genes. Two methods based on heterogeneous networks constructed using protein-protein interaction, gene-phenotype associations, and phenotype-phenotype similarity, are presented. In HeteSim_MultiPath (HSMP), HeteSim scores of different paths are combined with a constant that dampens the contributions of longer paths. In HeteSim_SVM (HSSVM), HeteSim scores are combined with a machine learning method. The 3-fold experiments show that our non-machine learning method HSMP performs better than the existing non-machine learning methods, our machine learning method HSSVM obtains similar accuracy with the best existing machine learning method CATAPULT. From the analysis of the top 10 predicted genes for different diseases, we found that HSSVM avoid the disadvantage of the existing machine learning based methods, which always predict similar genes for different diseases. The data sets and Matlab code for the two methods are freely available for download at http://lab.malab.cn/data/HeteSim/index.jsp.

  14. Preparation of Authigenic Pyrite from Methane-bearing Sediments for In Situ Sulfur Isotope Analysis Using SIMS.

    PubMed

    Lin, Zhiyong; Sun, Xiaoming; Peckmann, Jörn; Lu, Yang; Strauss, Harald; Xu, Li; Lu, Hongfeng; Teichert, Barbara M A

    2017-08-31

    Different sulfur isotope compositions of authigenic pyrite typically result from the sulfate-driven anaerobic oxidation of methane (SO4-AOM) and organiclastic sulfate reduction (OSR) in marine sediments. However, unravelling the complex pyritization sequence is a challenge because of the coexistence of different sequentially formed pyrite phases. This manuscript describes a sample preparation procedure that enables the use of secondary ion mass spectroscopy (SIMS) to obtain in situ δ 34 S values of various pyrite generations. This allows researchers to constrain how SO4-AOM affects pyritization in methane-bearing sediments. SIMS analysis revealed an extreme range in δ 34 S values, spanning from -41.6 to +114.8‰, which is much wider than the range of δ 34 S values obtained by the traditional bulk sulfur isotope analysis of the same samples. Pyrite in the shallow sediment mainly consists of 34 S-depleted framboids, suggesting early diagenetic formation by OSR. Deeper in the sediment, more pyrite occurs as overgrowths and euhedral crystals, which display much higher SIMS δ 34 S values than the framboids. Such 34 S-enriched pyrite is related to enhanced SO4-AOM at the sulfate-methane transition zone, postdating OSR. High-resolution in situ SIMS sulfur isotope analyses allow for the reconstruction of the pyritization processes, which cannot be resolved by bulk sulfur isotope analysis.

  15. A novel ToF-SIMS operation mode for sub 100 nm lateral resolution: Application and performance.

    PubMed

    Kubicek, Markus; Holzlechner, Gerald; Opitz, Alexander K; Larisegger, Silvia; Hutter, Herbert; Fleig, Jürgen

    2014-01-15

    A novel operation mode for time of flight-secondary ion mass spectrometry (ToF-SIMS) is described for a TOF.SIMS 5 instrument with a Bi-ion gun. It features sub 100 nm lateral resolution, adjustable primary ion currents and the possibility to measure with high lateral resolution as well as high mass resolution. The adjustment and performance of the novel operation mode are described and compared to established ToF-SIMS operation modes. Several examples of application featuring novel scientific results show the capabilities of the operation mode in terms of lateral resolution, accuracy of isotope analysis of oxygen, and combination of high lateral and mass resolution. The relationship between high lateral resolution and operation of SIMS in static mode is discussed.

  16. Assessing vertebral fracture risk on volumetric quantitative computed tomography by geometric characterization of trabecular bone structure

    NASA Astrophysics Data System (ADS)

    Checefsky, Walter A.; Abidin, Anas Z.; Nagarajan, Mahesh B.; Bauer, Jan S.; Baum, Thomas; Wismüller, Axel

    2016-03-01

    The current clinical standard for measuring Bone Mineral Density (BMD) is dual X-ray absorptiometry, however more recently BMD derived from volumetric quantitative computed tomography has been shown to demonstrate a high association with spinal fracture susceptibility. In this study, we propose a method of fracture risk assessment using structural properties of trabecular bone in spinal vertebrae. Experimental data was acquired via axial multi-detector CT (MDCT) from 12 spinal vertebrae specimens using a whole-body 256-row CT scanner with a dedicated calibration phantom. Common image processing methods were used to annotate the trabecular compartment in the vertebral slices creating a circular region of interest (ROI) that excluded cortical bone for each slice. The pixels inside the ROI were converted to values indicative of BMD. High dimensional geometrical features were derived using the scaling index method (SIM) at different radii and scaling factors (SF). The mean BMD values within the ROI were then extracted and used in conjunction with a support vector machine to predict the failure load of the specimens. Prediction performance was measured using the root-mean-square error (RMSE) metric and determined that SIM combined with mean BMD features (RMSE = 0.82 +/- 0.37) outperformed MDCT-measured mean BMD (RMSE = 1.11 +/- 0.33) (p < 10-4). These results demonstrate that biomechanical strength prediction in vertebrae can be significantly improved through the use of SIM-derived texture features from trabecular bone.

  17. Image segmentation for uranium isotopic analysis by SIMS: Combined adaptive thresholding and marker controlled watershed approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willingham, David G.; Naes, Benjamin E.; Heasler, Patrick G.

    A novel approach to particle identification and particle isotope ratio determination has been developed for nuclear safeguard applications. This particle search approach combines an adaptive thresholding algorithm and marker-controlled watershed segmentation (MCWS) transform, which improves the secondary ion mass spectrometry (SIMS) isotopic analysis of uranium containing particle populations for nuclear safeguards applications. The Niblack assisted MCWS approach (a.k.a. SEEKER) developed for this work has improved the identification of isotopically unique uranium particles under conditions that have historically presented significant challenges for SIMS image data processing techniques. Particles obtained from five NIST uranium certified reference materials (CRM U129A, U015, U150, U500more » and U850) were successfully identified in regions of SIMS image data 1) where a high variability in image intensity existed, 2) where particles were touching or were in close proximity to one another and/or 3) where the magnitude of ion signal for a given region was count limited. Analysis of the isotopic distributions of uranium containing particles identified by SEEKER showed four distinct, accurately identified 235U enrichment distributions, corresponding to the NIST certified 235U/238U isotope ratios for CRM U129A/U015 (not statistically differentiated), U150, U500 and U850. Additionally, comparison of the minor uranium isotope (234U, 235U and 236U) atom percent values verified that, even in the absence of high precision isotope ratio measurements, SEEKER could be used to segment isotopically unique uranium particles from SIMS image data. Although demonstrated specifically for SIMS analysis of uranium containing particles for nuclear safeguards, SEEKER has application in addressing a broad set of image processing challenges.« less

  18. Binding properties of SUMO-interacting motifs (SIMs) in yeast.

    PubMed

    Jardin, Christophe; Horn, Anselm H C; Sticht, Heinrich

    2015-03-01

    Small ubiquitin-like modifier (SUMO) conjugation and interaction play an essential role in many cellular processes. A large number of yeast proteins is known to interact non-covalently with SUMO via short SUMO-interacting motifs (SIMs), but the structural details of this interaction are yet poorly characterized. In the present work, sequence analysis of a large dataset of 148 yeast SIMs revealed the existence of a hydrophobic core binding motif and a preference for acidic residues either within or adjacent to the core motif. Thus the sequence properties of yeast SIMs are highly similar to those described for human. Molecular dynamics simulations were performed to investigate the binding preferences for four representative SIM peptides differing in the number and distribution of acidic residues. Furthermore, the relative stability of two previously observed alternative binding orientations (parallel, antiparallel) was assessed. For all SIMs investigated, the antiparallel binding mode remained stable in the simulations and the SIMs were tightly bound via their hydrophobic core residues supplemented by polar interactions of the acidic residues. In contrary, the stability of the parallel binding mode is more dependent on the sequence features of the SIM motif like the number and position of acidic residues or the presence of additional adjacent interaction motifs. This information should be helpful to enhance the prediction of SIMs and their binding properties in different organisms to facilitate the reconstruction of the SUMO interactome.

  19. Search for a scalar partner of the top quark in the jets plus missing transverse momentum final state at $$\\sqrt{s}=13 $$ TeV with the ATLAS detector

    DOE PAGES

    Aaboud, M.; Aad, G.; Abbott, B.; ...

    2017-12-15

    A search for pair production of a scalar partner of the top quark in events with four or more jets plus missing transverse momentum is presented. Here, an analysis of 36.1 fb -1 ofmore » $$ \\sqrt{s}=13 $$ TeV proton-proton collisions collected using the ATLAS detector at the LHC yields no significant excess over the expected Standard Model background. To interpret the results a simplified supersymmetric model is used where the top squark is assumed to decay via $$\\sim\\atop{t}$$ 1→t(*)$$\\sim\\atop{χ}$$ $$0\\atop{1}$$ and $$\\sim\\atop{t}$$ 1→b$$\\sim\\atop{χ}$$ $$±\\atop{1}$$→bW(*)$$\\sim\\atop{χ}$$ $$0\\atop{1}$$, where χ 1 0 (χ 1 ± ) denotes the lightest neutralino (chargino). Exclusion limits are placed in terms of the top-squark and neutralino masses. Assuming a branching ratio of 100% to t$$\\sim\\atop{χ}$$ $$0\\atop{1}$$, top-squark masses in the range 450–1000 GeV are excluded for $$\\sim\\atop{χ}$$ $$0\\atop{1}$$ masses below 160 GeV. In the case where m$$\\sim\\atop{t}$$ 1-m t+m $$\\sim\\atop{χ}$$ $$0\\atop{1}$$ , top-squark masses in the range 235–590 GeV are excluded.« less

  20. Search for a scalar partner of the top quark in the jets plus missing transverse momentum final state at $$\\sqrt{s}=13 $$ TeV with the ATLAS detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aaboud, M.; Aad, G.; Abbott, B.

    A search for pair production of a scalar partner of the top quark in events with four or more jets plus missing transverse momentum is presented. Here, an analysis of 36.1 fb -1 ofmore » $$ \\sqrt{s}=13 $$ TeV proton-proton collisions collected using the ATLAS detector at the LHC yields no significant excess over the expected Standard Model background. To interpret the results a simplified supersymmetric model is used where the top squark is assumed to decay via $$\\sim\\atop{t}$$ 1→t(*)$$\\sim\\atop{χ}$$ $$0\\atop{1}$$ and $$\\sim\\atop{t}$$ 1→b$$\\sim\\atop{χ}$$ $$±\\atop{1}$$→bW(*)$$\\sim\\atop{χ}$$ $$0\\atop{1}$$, where χ 1 0 (χ 1 ± ) denotes the lightest neutralino (chargino). Exclusion limits are placed in terms of the top-squark and neutralino masses. Assuming a branching ratio of 100% to t$$\\sim\\atop{χ}$$ $$0\\atop{1}$$, top-squark masses in the range 450–1000 GeV are excluded for $$\\sim\\atop{χ}$$ $$0\\atop{1}$$ masses below 160 GeV. In the case where m$$\\sim\\atop{t}$$ 1-m t+m $$\\sim\\atop{χ}$$ $$0\\atop{1}$$ , top-squark masses in the range 235–590 GeV are excluded.« less

  1. Principal component analysis of TOF-SIMS spectra, images and depth profiles: an industrial perspective

    NASA Astrophysics Data System (ADS)

    Pacholski, Michaeleen L.

    2004-06-01

    Principal component analysis (PCA) has been successfully applied to time-of-flight secondary ion mass spectrometry (TOF-SIMS) spectra, images and depth profiles. Although SIMS spectral data sets can be small (in comparison to datasets typically discussed in literature from other analytical techniques such as gas or liquid chromatography), each spectrum has thousands of ions resulting in what can be a difficult comparison of samples. Analysis of industrially-derived samples means the identity of most surface species are unknown a priori and samples must be analyzed rapidly to satisfy customer demands. PCA enables rapid assessment of spectral differences (or lack there of) between samples and identification of chemically different areas on sample surfaces for images. Depth profile analysis helps define interfaces and identify low-level components in the system.

  2. Secondary ion mass spectrometers (SIMS) for calcium isotope measurements as an application to biological samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Craven, S.M.; Hoenigman, J.R.; Moddeman, W.E.

    1981-11-20

    The potential use of secondary ion mass spectroscopy (SIMS) to analyze biological samples for calcium isotopes is discussed. Comparison of UTI and Extranuclear based quadrupole systems is made on the basis of the analysis of CaO and calcium metal. The Extranuclear quadrupole based system is superior in resolution and sensitivity to the UTI system and is recommended. For determination of calcium isotopes to within an accuracy of a few percent a high resolution quadrupole, such as the Extranuclear, and signal averaging capability are required. Charge neutralization will be mandated for calcium oxide, calcium nitrate, or calcium oxalate. SIMS is notmore » capable of the high precision and high accuracy results possible by thermal ionization methods, but where faster analysis is desirable with an accuracy of a few percent, SIMS is a viable alternative.« less

  3. SIMS chemical and isotopic analysis of impact features from LDEF experiments AO187-1 and AO187-2

    NASA Technical Reports Server (NTRS)

    Stadermann, Frank J.; Amari, Sachiko; Foote, John; Swan, Pat; Walker, Robert M.; Zinner, Ernst

    1995-01-01

    Previous secondary ion mass spectrometry (SIMS) studies of extended impact features from LDEF capture cell experiment AO187-2 showed that it is possible to distinguish natural and man-made particle impacts based on the chemical composition of projectile residues. The same measurement technique has now been applied to specially prepared gold target impacts from experiment AO187-1 in order to identify the origins of projectiles that left deposits too thin to be analyzed by conventional energy-dispersive x-ray (EDX) spectroscopy. The results indicate that SIMS may be the method of choice for the analysis of impact deposits on a variety of sample surfaces. SIMS was also used to determine the isotopic compositions of impact residues from several natural projectiles. Within the precision of the measurements all analyzed residues show isotopically normal compositions.

  4. Search for direct top squark pair production in events with a $Z$ boson, $b$-jets and missing transverse momentum in $$\\sqrt{s}$$= 8 TeV $pp$ collisions with the ATLAS detector

    DOE PAGES

    Aad, G.; Abbott, B.; Abdallah, J.; ...

    2014-06-01

    Here, a search is presented for direct top squark pair production using events with at least two leptons including a same-flavour opposite-sign pair with invariant mass consistent with the Z boson mass, jets tagged as originating from b-quarks and missing transverse momentum. The analysis is performed with proton–proton collision data at √s = 8 TeV collected with the ATLAS detector at the LHC in 2012 corresponding to an integrated luminosity of 20.3 fb -1. No excess beyond the Standard Model expectation is observed. Interpretations of the results are provided in models based on the direct pair production of the heavier top squark state (more » $$\\sim\\atop{t}_2$$) followed by the decay to the lighter top squark state ($$\\sim\\atop{t}_1$$) via $$\\sim\\atop{t}_2$$ → Z$$\\sim\\atop{t}_1$$, and for $$\\sim\\atop{t}_1$$ pair production in natural gauge-mediated supersymmetry breaking scenarios where the neutralino ($$\\sim\\atop{χ}$$$0\\atop{1}$$) is the next-to-lightest supersymmetric particle and decays producing a Z boson and a gravitino ($$\\sim\\atop{G}$$) via the $$\\sim\\atop{χ}$$$0\\atop{1}$$ → Z G process.« less

  5. Graphene Oxide as a Novel Evenly Continuous Phase Matrix for TOF-SIMS.

    PubMed

    Cai, Lesi; Sheng, Linfeng; Xia, Mengchan; Li, Zhanping; Zhang, Sichun; Zhang, Xinrong; Chen, Hongyuan

    2017-03-01

    Using matrix to enhance the molecular ion signals for biomolecule identification without loss of spatial resolution caused by matrix crystallization is a great challenge for the application of TOF-SIMS in real-world biological research. In this report, graphene oxide (GO) was used as a matrix for TOF-SIMS to improve the secondary ion yields of intact molecular ions ([M + H] + ). Identifying and distinguishing the molecular ions of lipids (m/z >700) therefore became straightforward. The spatial resolution of TOF-SIMS imaging could also be improved as GO can form a homogeneous layer of matrix instead of crystalline domain, which prevents high spatial resolution in TOF-SIMS imaging. Lipid mapping in presence of GO revealed the delicate morphology and distribution of single vesicles with a diameter of 800 nm. On GO matrix, the vesicles with similar shape but different chemical composition could be distinguished using molecular ions. This novel matrix holds potentials in such applications as the analysis and imaging of complex biological samples by TOF-SIMS. Graphical Abstract ᅟ.

  6. Graphene Oxide as a Novel Evenly Continuous Phase Matrix for TOF-SIMS

    NASA Astrophysics Data System (ADS)

    Cai, Lesi; Sheng, Linfeng; Xia, Mengchan; Li, Zhanping; Zhang, Sichun; Zhang, Xinrong; Chen, Hongyuan

    2017-03-01

    Using matrix to enhance the molecular ion signals for biomolecule identification without loss of spatial resolution caused by matrix crystallization is a great challenge for the application of TOF-SIMS in real-world biological research. In this report, graphene oxide (GO) was used as a matrix for TOF-SIMS to improve the secondary ion yields of intact molecular ions ([M + H]+). Identifying and distinguishing the molecular ions of lipids ( m/z >700) therefore became straightforward. The spatial resolution of TOF-SIMS imaging could also be improved as GO can form a homogeneous layer of matrix instead of crystalline domain, which prevents high spatial resolution in TOF-SIMS imaging. Lipid mapping in presence of GO revealed the delicate morphology and distribution of single vesicles with a diameter of 800 nm. On GO matrix, the vesicles with similar shape but different chemical composition could be distinguished using molecular ions. This novel matrix holds potentials in such applications as the analysis and imaging of complex biological samples by TOF-SIMS.

  7. Application of wide selected-ion monitoring data-independent acquisition to identify tomato fruit proteins regulated by the CUTIN DEFICIENT2 transcription factor

    PubMed Central

    Martin, Laetitia B. B.; Sherwood, Robert W.; Nicklay, Joshua J.; Yang, Yong; Muratore-Schroeder, Tara L.; Anderson, Elizabeth T.; Thannhauser, Theodore W.; Rose, Jocelyn K. C.; Zhang, Sheng

    2017-01-01

    We describe here the use of label-free wide selected-ion monitoring data-independent acquisition (WiSIM-DIA) to identify proteins that are involved in the formation of tomato (Solanum lycopersicum) fruit cuticles and that are regulated by the transcription factor CUTIN DEFICIENT2 (CD2). A spectral library consisting of 11 753 unique peptides, corresponding to 2338 tomato protein groups, was used and the DIA analysis was performed at the MS1 level utilizing narrow mass windows for extraction with Skyline 2.6 software. We identified a total of 1140 proteins, 67 of which had expression levels that differed significantly between the cd2 tomato mutant and the wild-type cultivar M82. Differentially expressed proteins including a key protein involved in cutin biosynthesis, were selected for validation by target SRM/MRM and by Western blot analysis. In addition to confirming a role for CD2 in regulating cuticle formation, the results also revealed that CD2 influences pathways associated with cell wall biology, anthocyanin biosynthesis, plant development, and responses to stress, which complements findings of earlier RNA-Seq experiments. Our results provide new insights into molecular processes and aspects of fruit biology associated with CD2 function, and demonstrate that the WiSIM-DIA is an effective quantitative approach for global protein identifications. PMID:27089858

  8. The Structured Inventory of Malingered Symptomatology (SIMS): a systematic review and meta-analysis.

    PubMed

    van Impelen, Alfons; Merckelbach, Harald; Jelicic, Marko; Merten, Thomas

    2014-01-01

    We meta-analytically reviewed studies that used the Structured Inventory of Malingered Symptomatology (SIMS) to detect feigned psychopathology. We present weighted mean diagnostic accuracy and predictive power indices in various populations, based on 31 studies, including 61 subsamples and 4009 SIMS protocols. In addition, we provide normative data of patients, claimants, defendants, nonclinical adults, and various experimental feigners, based on 41 studies, including 125 subsamples and 4810 SIMS protocols. We conclude that the SIMS (1) is able to differentiate well between instructed feigners and honest responders; (2) generates heightened scores in groups that are known to have a raised prevalence of feigning (e.g., offenders who claim crime-related amnesia); (3) may overestimate feigning in patients who suffer from schizophrenia, intellectual disability, or psychogenic non-epileptic seizures; and (4) is fairly robust against coaching. The diagnostic power of the traditional cut scores of the SIMS (i.e., > 14 and > 16) is not so much limited by their sensitivity—which is satisfactory—but rather by their substandard specificity. This, however, can be worked around by combining the SIMS with other symptom validity measures and by raising the cut score, although the latter solution sacrifices sensitivity for specificity.

  9. Research on the SIM card implementing functions of transport card

    NASA Astrophysics Data System (ADS)

    Li, Yi; Wang, Lin

    2015-12-01

    This paper is based on the analysis for theory and key technologies of contact communication, contactless communication card and STK menu, and proposes complete software and hardware solution for achieving convenience and secure mobile payment system on SIM card.

  10. Time-of-flight SIMS/MSRI reflectron mass analyzer and method

    DOEpatents

    Smentkowski, Vincent S.; Gruen, Dieter M.; Krauss, Alan R.; Schultz, J. Albert; Holecek, John C.

    1999-12-28

    A method and apparatus for analyzing the surface characteristics of a sample by Secondary Ion Mass Spectroscopy (SIMS) and Mass Spectroscopy of Recoiled Ions (MSRI) is provided. The method includes detecting back scattered primary ions, low energy ejected species, and high energy ejected species by ion beam surface analysis techniques comprising positioning a ToF SIMS/MSRI mass analyzer at a predetermined angle .theta., where .theta. is the angle between the horizontal axis of the mass analyzer and the undeflected primary ion beam line, and applying a specific voltage to the back ring of the analyzer. Preferably, .theta. is less than or equal to about 120.degree. and, more preferably, equal to 74.degree.. For positive ion analysis, the extractor, lens, and front ring of the reflectron are set at negative high voltages (-HV). The back ring of the reflectron is set at greater than about +700V for MSRI measurements and between the range of about +15 V and about +50V for SIMS measurements. The method further comprises inverting the polarity of the potentials applied to the extractor, lens, front ring, and back ring to obtain negative ion SIMS and/or MSRI data.

  11. Qualitative analysis of precipitate formation on the surface and in the tubules of dentin irrigated with sodium hypochlorite and a final rinse of chlorhexidine or QMiX.

    PubMed

    Kolosowski, Kamil P; Sodhi, Rana N S; Kishen, Anil; Basrani, Bettina R

    2014-12-01

    Interaction of sodium hypochlorite (NaOCl) mixed with chlorhexidine (CHX) produces a brown precipitate containing para-chloroaniline (PCA). When QMiX is mixed with NaOCl, no precipitate forms, but color change occurs. The aim of this study was to qualitatively assess the formation of precipitate and PCA on the surface and in the tubules of dentin irrigated with NaOCl, followed either by EDTA, NaOCl, and CHX or by saline and QMiX by using time-of-flight secondary ion mass spectrometry (TOF-SIMS). Dentin blocks were obtained from human maxillary molars, embedded in resin, and cross-sectioned to expose dentin. Specimens in group 1 were immersed in 2.5% NaOCl, followed by 17% EDTA, 2.5% NaOCl, and 2% CHX. Specimens in group 2 were immersed in 2.5% NaOCl, followed by saline and QMiX. The dentin surfaces were subjected to TOF-SIMS spectra analysis. Longitudinal sections of dentin blocks were then exposed and subjected to TOF-SIMS analysis. All samples and analysis were performed in triplicate for confirmation. TOF-SIMS analysis of group 1 revealed an irregular precipitate, containing PCA and CHX breakdown products, on the dentin surfaces, occluding and extending into the tubules. In TOF-SIMS analysis of group 2, no precipitates, including PCA, were detected on the dentin surface or in the tubules. Within the limitations of this study, precipitate containing PCA was formed in the tubules of dentin irrigated with NaOCl followed by CHX. No precipitates or PCA were detected in the tubules of dentin irrigated with NaOCl followed by saline and QMiX. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  12. Optimized conditions for selective gold flotation by ToF-SIMS and ToF-LIMS

    NASA Astrophysics Data System (ADS)

    Chryssoulis, S. L.; Dimov, S. S.

    2004-06-01

    This work describes a comprehensive characterization of the factors controlling the floatability of free gold from flotation test using reagents (collectors) at plant concentration levels. A relationship between the collectors loadings on gold particles and their surface composition has been established. The findings of this study show that silver activates gold flotation and there is a strong correlation between the surface concentration of silver and the loading of certain collectors. The organic surface analysis was done by ToF-SIMS while the inorganic surface analysis was carried out by time-of-flight laser ionization mass spectrometry (ToF-LIMS). The developed testing protocol based on ToF-LIMS and ToF-SIMS complementary surface analysis allows for optimization of the flotation scheme and hence improved gold recovery.

  13. A holistic approach to SIM platform and its application to early-warning satellite system

    NASA Astrophysics Data System (ADS)

    Sun, Fuyu; Zhou, Jianping; Xu, Zheyao

    2018-01-01

    This study proposes a new simulation platform named Simulation Integrated Management (SIM) for the analysis of parallel and distributed systems. The platform eases the process of designing and testing both applications and architectures. The main characteristics of SIM are flexibility, scalability, and expandability. To improve the efficiency of project development, new models of early-warning satellite system were designed based on the SIM platform. Finally, through a series of experiments, the correctness of SIM platform and the aforementioned early-warning satellite models was validated, and the systematical analyses for the orbital determination precision of the ballistic missile during its entire flight process were presented, as well as the deviation of the launch/landing point. Furthermore, the causes of deviation and prevention methods will be fully explained. The simulation platform and the models will lay the foundations for further validations of autonomy technology in space attack-defense architecture research.

  14. Economic analysis of standard interface modules for use with the multi-mission spacecraft. Volume 2: Appendices and drawings

    NASA Technical Reports Server (NTRS)

    Greenberg, J. S.; Miller, B. P.; Russell, S.; Becar, N.

    1976-01-01

    The cost savings that could be obtained by the use of SIM to perform certain sensor electrical interfacing functions that were historically an integral part of the sensor are evaluated. Reduction in both the nonrecurring and recurring costs of this sensor interface hardware could be achieved through the use of SIM, and the study concludes that the development and use of certain power conditioning and data handling SIM units are economically justified.

  15. Resistivity analysis of epitaxially grown, doped semiconductors using energy dependent secondary ion mass spectroscopy

    NASA Astrophysics Data System (ADS)

    Burnham, Shawn D.; Thomas, Edward W.; Doolittle, W. Alan

    2006-12-01

    A characterization technique is discussed that allows quantitative optimization of doping in epitaxially grown semiconductors. This technique uses relative changes in the host atom secondary ion (HASI) energy distribution from secondary ion mass spectroscopy (SIMS) to indicate relative changes in conductivity of the material. Since SIMS is a destructive process due to sputtering through a film, a depth profile of the energy distribution of sputtered HASIs in a matrix will contain information on the conductivity of the layers of the film as a function of depth. This process is demonstrated with Mg-doped GaN, with the Mg flux slowly increased through the film. Three distinct regions of conductivity were observed: one with Mg concentration high enough to cause compensation and thus high resistivity, a second with moderate Mg concentration and low resistivity, and a third with little to no Mg doping, causing high resistivity due to the lack of free carriers. During SIMS analysis of the first region, the energy distributions of sputtered Ga HASIs were fairly uniform and unchanging for a Mg flux above the saturation, or compensation, limit. For the second region, the Ga HASI energy distributions shifted and went through a region of inconsistent energy distributions for Mg flux slightly below the critical flux for saturation, or compensation. Finally, for the third region, the Ga HASI energy distributions then settled back into another fairly unchanging, uniform pattern. These three distinct regions were analyzed further through growth of Mg-doped step profiles and bulk growth of material at representative Mg fluxes. The materials grown at the two unchanging, uniform regions of the energy distributions yielded highly resistive material due to too high of Mg concentration and low to no Mg concentration, respectively. However, material grown in the transient energy distribution region with Mg concentration between that of the two highly resistive regions yielded low resistivity (0.59Ωcm) and highly p-type (1.2×1018cm-3 holes) Mg-doped GaN.

  16. Image fusion of Secondary Ion Mass Spectrometry and Energy-dispersive X-Ray Spectroscopy data for the characterization of uranium-molybdenum fuel foils

    NASA Astrophysics Data System (ADS)

    Willingham, David; Naes, Benjamin E.; Tarolli, Jay G.; Schemer-Kohrn, Alan; Rhodes, Mark; Dahl, Michael; Guzman, Anthony; Burkes, Douglas E.

    2018-01-01

    Uranium-molybdenum (U-Mo) monolithic fuels represent one option for converting civilian research and test reactors operating with high enriched uranium (HEU) to low enriched uranium (LEU), effectively reducing the threat of nuclear proliferation world-wide. However, processes associated with fabrication of U-Mo monolithic fuels result in regions of elemental heterogeneity, observed as bands traversing the cross-section of representative samples. Isotopic variations (e.g., 235U and 238U) could also be introduced because of associated processing steps, particularly since HEU feedstock is melted with natural or depleted uranium diluent to produce LEU. This study demonstrates the utility of correlative analysis of Energy-Dispersive X-ray Spectroscopy (EDS) and Secondary Ion Mass Spectrometry (SIMS) with their image data streams using image fusion, resulting in a comprehensive microanalytical characterization toolbox. Elemental and isotopic measurements were made on a sample from the Advanced Test Reactor (ATR) Full-sized plate In-center flux trap Position (AFIP)-7 experiment and compared to previous optical and electron microscopy results. The image fusion results are characteristic of SIMS isotopic maps, but with the spatial resolution of EDS images and, therefore, can be used to increase the effective spatial resolution of the SIMS imaging results to better understand homogeneity or heterogeneity that persists because of processing selections. Visual inspection using the image fusion methodology indicated slight variations in the 235U/238U ratio and quantitative analysis using the image intensities across several FoVs revealed an average 235U atom percent value of 17.9 ± 2.4%, which was indicative of a non-uniform U isotopic distribution in the area sampled. Further development of this capability is useful for understanding the connections between the properties of LEU fuel alternatives and the ability to predict performance under irradiation.

  17. Combined SIMS, NanoSIMS, FTIR, and SEM Studies of OH in Nominally Anhydrous Minerals (NAMs)

    NASA Astrophysics Data System (ADS)

    Mosenfelder, J. L.; Le Voyer, M.; Rossman, G. R.; Guan, Y.; Bell, D. R.; Asimow, P. D.; Eiler, J.

    2010-12-01

    The accurate analysis of trace concentrations of hydrogen in NAMs is a long-standing problem, with wide-ranging implications in geology and planetology. SIMS and FTIR are two powerful and complementary analytical tools capable of measuring concentrations down to levels of less than 1 ppm H2O. Both methods, however, are subject to matrix effects and rely on other techniques such as manometry or nuclear reaction analysis (NRA) for quantitative calibration. We compared FTIR and SIMS data for a wide variety of NAMs: olivine, orthopyroxene, clinopyroxene, pyrope and grossular garnet, rutile, zircon, kyanite, andalusite, and sillimanite. Some samples were also characterized using high-resolution FE-SEM to assess the potential contribution of submicrocopic inclusions to the analyses. For SIMS, we use high mass resolution (≥5000 MRP) to measure 16O1H, using 30Si and/or 18O as reference isotopes. We use both primary standards, measured independently using manometry or NRA (e.g., [1]), and secondary standards, measured using polarized FTIR referenced back to calibrations developed on primary standards. Our major focus was on on olivine, for which we collected repeated calibration data with both SIMS and NanoSIMS, bracketing measurements of H diffusion profiles in both natural and experimentally annealed crystals at levels of 5-100 ppm H2O. With both instruments we establish low blanks (≤5 ppm) and high precision (typically less than 5% 2-σ errors in 16O1H/30Si), critical requirements for the low concentration levels being measured. Assessment of over 300 analyses on 11 olivines allows us to evaluate the suitability of different standards, several of which are in use in other laboratories [2,3,4]. Seven olivines, with 0-125 ppm H2O, give highly reproducible results and allow us to establish well-constrained calibration slopes with high correlation coefficients (r2 = 0.98-99), in contrast to previous studies [2,3,4]. However, four kimberlitic megacrysts with 140-243 ppm H2O show 16O1H/30Si ratios that vary by up to a factor of 2 even in sequential analyses (cf. [3,4]). A potential cause of these discrepancies is the presence of sub-micron scale pores (as small as 100 nm), which we have documented by SEM. These pores probably contain liquid H2O and/or condensed hydrous phase precipitates. Although the ionization potential of fluids under high-vacuum conditions is an under-studied problem, these sub-micron features may contribute to the measured 16O1H, resulting in analyses with erratic depth profiles and corresponding high uncertainties (up to 15% 2-σ). However, if we omit analyses with such high uncertainties, the data for all olivines fit well together. Our results imply that the Bell et al. IR calibration [1] can be applied accurately to all olivines with IR bands from ~3400-3650 cm-1, without the need for band-specific IR absorption coefficients (cf. [3]). A five-fold total variation was observed among the calibration line slopes for the different minerals analyzed, confirming the need for mineral-specific calibrations. [1]Bell et al. (2003), JGR, 108 [2] Tenner et al. (2009), Chem. Geol., 262, 42-56 [3] Kovács, I. et al. (2010), Am. Min., 95, 292-299 [4] O'Leary et al. (2010), EPSL

  18. Local delivery of controlled-release simvastatin to improve the biocompatibility of polyethylene terephthalate artificial ligaments for reconstruction of the anterior cruciate ligament.

    PubMed

    Zhang, Peng; Han, Fei; Li, Yunxia; Chen, Jiwu; Chen, Tianwu; Zhi, Yunlong; Jiang, Jia; Lin, Chao; Chen, Shiyi; Zhao, Peng

    2016-01-01

    The Ligament Advanced Reinforcement System has recently been widely used as the primary graft of choice in anterior cruciate ligament (ACL) reconstruction. But the biological graft-bone healing still remains a problem. Previous studies have shown that simvastatin (SIM) stimulates bone formation. The objective of this study was to investigate whether surface coating with collagen containing low-dose SIM microsphere could enhance the surface biocompatibility of polyethylene terephthalate (PET) artificial ligaments to accelerate graft-to-bone healing. The in vitro studies demonstrated that bone marrow stromal cells on the collagen-coated PET scaffolds (COL/PET) and simvastatin/collagen-coated PET scaffolds (SIM/COL/PET) proliferated vigorously. Compared with the PET group and the COL/PET group, SIM could induce bone marrow stromal cells' osteoblastic differentiation, high alkaline phosphatase activity, more mineralization deposition, and more expression of osteoblast-related genes, such as osteocalcin, runt-related transcription factor 2, bone morphogenetic protein-2, and vascular endothelial growth factor, in the SIM/COL/PET group. In vivo, rabbits received ACL reconstruction with different scaffolds. Histological analysis demonstrated that graft-bone healing was significantly greater with angiogenesis and osteogenesis in the SIM/COL/PET group than the other groups. In addition, biomechanical testing at the eighth week demonstrated a significant increase in the ultimate failure load and stiffness in the SIM/COL/PET group. The low dose of SIM-sustained release from SIM/COL/PET promoted the graft-bone healing via its effect on both angiogenesis and osteogenesis. This study suggested that collagen containing low-dose SIM microsphere coating on the surface of PET artificial ligaments could be potentially applied for ACL reconstruction.

  19. Fast quantitative analysis of boric acid by gas chromatography-mass spectrometry coupled with a simple and selective derivatization reaction using triethanolamine.

    PubMed

    Zeng, Li-Min; Wang, Hao-Yang; Guo, Yin-Long

    2010-03-01

    A fast, selective, and sensitive GC-MS method has been developed and validated for the determination of boric acid in the drinking water by derivatization with triethanolamine. This analytic strategy successfully converts the inorganic, nonvolatile boric acid B(OH)(3) present in the drinking water to a volatile triethanolamine borate B(OCH(2)CH(2))(3)N in a quantitative manner, which facilitates the GC measurement. The SIM mode was applied in the analysis and showed high accuracy, specificity, and reproducibility, as well as reducing the matrix effect effectively. The calibration curve was obtained from 0.01 microg/mL to 10.0 microg/mL with a satisfactory correlation coefficient of 0.9988. The limit of detection for boric acid was 0.04 microg/L. Then the method was applied for detection of the amount of boric acid in bottled drinking water and the results are in accordance with the reported concentration value of boric acid. This study offers a perspective into the utility of GC-MS as an alternate quantitative tool for detection of B(OH)(3), even for detection of boron in various other samples by digesting the boron compounds to boric acid. Copyright 2010 American Society for Mass Spectrometry. Published by Elsevier Inc. All rights reserved.

  20. NICeSim: an open-source simulator based on machine learning techniques to support medical research on prenatal and perinatal care decision making.

    PubMed

    Cerqueira, Fabio Ribeiro; Ferreira, Tiago Geraldo; de Paiva Oliveira, Alcione; Augusto, Douglas Adriano; Krempser, Eduardo; Corrêa Barbosa, Helio José; do Carmo Castro Franceschini, Sylvia; de Freitas, Brunnella Alcantara Chagas; Gomes, Andreia Patricia; Siqueira-Batista, Rodrigo

    2014-11-01

    This paper describes NICeSim, an open-source simulator that uses machine learning (ML) techniques to aid health professionals to better understand the treatment and prognosis of premature newborns. The application was developed and tested using data collected in a Brazilian hospital. The available data were used to feed an ML pipeline that was designed to create a simulator capable of predicting the outcome (death probability) for newborns admitted to neonatal intensive care units. However, unlike previous scoring systems, our computational tool is not intended to be used at the patients bedside, although it is possible. Our primary goal is to deliver a computational system to aid medical research in understanding the correlation of key variables with the studied outcome so that new standards can be established for future clinical decisions. In the implemented simulation environment, the values of key attributes can be changed using a user-friendly interface, where the impact of each change on the outcome is immediately reported, allowing a quantitative analysis, in addition to a qualitative investigation, and delivering a totally interactive computational tool that facilitates hypothesis construction and testing. Our statistical experiments showed that the resulting model for death prediction could achieve an accuracy of 86.7% and an area under the receiver operating characteristic curve of 0.84 for the positive class. Using this model, three physicians and a neonatal nutritionist performed simulations with key variables correlated with chance of death. The results indicated important tendencies for the effect of each variable and the combination of variables on prognosis. We could also observe values of gestational age and birth weight for which a low Apgar score and the occurrence of respiratory distress syndrome (RDS) could be less or more severe. For instance, we have noticed that for a newborn with 2000 g or more the occurrence of RDS is far less problematic than for neonates weighing less. The significant accuracy demonstrated by our predictive model shows that NICeSim might be used for hypothesis testing to minimize in vivo experiments. We observed that the model delivers predictions that are in very good agreement with the literature, demonstrating that NICeSim might be an important tool for supporting decision making in medical practice. Other very important characteristics of NICeSim are its flexibility and dynamism. NICeSim is flexible because it allows the inclusion and deletion of variables according to the requirements of a particular study. It is also dynamic because it trains a just-in-time model. Therefore, the system is improved as data from new patients become available. Finally, NICeSim can be extended in a cooperative manner because it is an open-source system. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Determination of oligomeric chain length distributions at surfaces using ToF-SIMS: segregation effects and polymer properties

    NASA Astrophysics Data System (ADS)

    Gardella, Joseph A.; Mahoney, Christine M.

    2004-06-01

    While many XPS and SIMS studies of polymers have detected and quantified segregation of low surface energy blocks or components in copolymers and polymer blends [D. Briggs, in: D.R. Clarke, S. Suresh, I.M. Ward (Eds.), Surface Analysis of Polymers by XPS and Static SIMS, Cambridge University Press, Cambridge, 1998 (Chapter 5).], this paper reports ToF-SIMS studies of direct measurement of the segment length distribution at the surface of siloxane copolymers. These data allow insight into the segregation of particular portions of the oligomeric distribution; specifically, in this study, longer PDMS oligomers segregated at the expense of shorter PDMS chains. We have reported XPS analysis of competitive segregation effects for short PDMS chains [Macromolecules 35 (13) (2002) 5256]. In this study, a series of poly(ureaurethane)-poly(dimethylsiloxane) (PUU-PDMS) copolymers have been synthesized containing varying ratios of G-3 and G-9 (G- X describes the average segment length of the PDMS added), while maintaining a constant overall siloxane weight percentage (10, 30, and 60%). These copolymers were utilized as model systems to study the preferential segregation of certain siloxane segment lengths to the surface over others. ToF-SIMS analysis of PUU-PDMS copolymers has yielded high-mass range copolymer fragmentation patterns containing intact PDMS segments. For the first time, this information is utilized to determine PDMS segment length distributions at the copolymer surface as compared to the bulk. The results show that longer siloxane segment lengths are preferentially segregating to the surface over shorter chain lengths. These results also show the importance of ToF-SIMS and mass spectrometry in the development of new materials containing low molecular weight amino-propyl-terminated siloxanes.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Li; Zhu, Zihua; Yu, Xiao-Ying

    Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a unique surface analysis technique because it can provide molecular recognition for organic and biological molecules. However, analyzing aqueous solution surfaces by ToF-SIMS is difficult, because ToF-SIMS is a high-vacuum technique, while the vapor pressure of water is about 2.3 kPa at room temperature (20 C). We designed and fabricated a self-contained microfluidic device, enabling in situ analysis of aqueous surfaces by scanning electron microscope (SEM) and ToF-SIMS, which has been briefly reported.1,2 In this study, we report more performance data, focusing on the performance of this device for in situ analysis ofmore » organic molecules at aqueous surfaces using ToF-SIMS. Three representative organic compounds (formic acid, glycerol, and glutamic acid) were tested, and their molecular signals were successfully observed. The device can be self-running in vacuum for 8 hours, and SIMS measurements are feasible at any time in this time range. The stability of this device under primary ion beam bombardment is also impressive. High fluence (6 × 1012 ions cm-2 s-1) measurements can be operated continuously for up to 30 minutes without any significant damage to the aperture. However, extra-high fluence measurements (>1 × 1014 ions cm-2 s-1) may lead to liquid bumping in the aperture, and the aqueous solutions may spread out quickly. Signal reproducibility is reasonably good, and relative standard deviation (RSD) for molecular ion signals can be controlled to be smaller than ±15% for consecutive measurements. Measurements at long time intervals (e.g., 60 min) show RSDs of ±40-50%. In addition, the detection limits of formic acid, glycerol, and glutamic acid are estimated to be 0.04%, 0.008%, and 0.002% (weight ratio), respectively.« less

  3. Imaging of Al/Fe ratios in synthetic Al-goethite revealed by nanoscale secondary ion mass spectrometry.

    PubMed

    Pohl, Lydia; Kölbl, Angelika; Werner, Florian; Mueller, Carsten W; Höschen, Carmen; Häusler, Werner; Kögel-Knabner, Ingrid

    2018-04-30

    Aluminium (Al)-substituted goethite is ubiquitous in soils and sediments. The extent of Al-substitution affects the physicochemical properties of the mineral and influences its macroscale properties. Bulk analysis only provides total Al/Fe ratios without providing information with respect to the Al-substitution of single minerals. Here, we demonstrate that nanoscale secondary ion mass spectrometry (NanoSIMS) enables the precise determination of Al-content in single minerals, while simultaneously visualising the variation of the Al/Fe ratio. Al-substituted goethite samples were synthesized with increasing Al concentrations of 0.1, 3, and 7 % and analysed by NanoSIMS in combination with established bulk spectroscopic methods (XRD, FTIR, Mössbauer spectroscopy). The high spatial resolution (50-150 nm) of NanoSIMS is accompanied by a high number of single-point measurements. We statistically evaluated the Al/Fe ratios derived from NanoSIMS, while maintaining the spatial information and reassigning it to its original localization. XRD analyses confirmed increasing concentration of incorporated Al within the goethite structure. Mössbauer spectroscopy revealed 11 % of the goethite samples generated at high Al concentrations consisted of hematite. The NanoSIMS data show that the Al/Fe ratios are in agreement with bulk data derived from total digestion and demonstrated small spatial variability between single-point measurements. More advantageously, statistical analysis and reassignment of single-point measurements allowed us to identify distinct spots with significantly higher or lower Al/Fe ratios. NanoSIMS measurements confirmed the capacity to produce images, which indicated the uniform increase in Al-concentrations in goethite. Using a combination of statistical analysis with information from complementary spectroscopic techniques (XRD, FTIR and Mössbauer spectroscopy) we were further able to reveal spots with lower Al/Fe ratios as hematite. Copyright © 2018 John Wiley & Sons, Ltd.

  4. SimAlba: A Spatial Microsimulation Approach to the Analysis of Health Inequalities

    PubMed Central

    Campbell, Malcolm; Ballas, Dimitris

    2016-01-01

    This paper presents applied geographical research based on a spatial microsimulation model, SimAlba, aimed at estimating geographically sensitive health variables in Scotland. SimAlba has been developed in order to answer a variety of “what-if” policy questions pertaining to health policy in Scotland. Using the SimAlba model, it is possible to simulate the distributions of previously unknown variables at the small area level such as smoking, alcohol consumption, mental well-being, and obesity. The SimAlba microdataset has been created by combining Scottish Health Survey and Census data using a deterministic reweighting spatial microsimulation algorithm developed for this purpose. The paper presents SimAlba outputs for Scotland’s largest city, Glasgow, and examines the spatial distribution of the simulated variables for small geographical areas in Glasgow as well as the effects on individuals of different policy scenario outcomes. In simulating previously unknown spatial data, a wealth of new perspectives can be examined and explored. This paper explores a small set of those potential avenues of research and shows the power of spatial microsimulation modeling in an urban context. PMID:27818989

  5. Effect of Primary-Ion Current Density on Charge Compensation in SIMS Analysis of a Quartz Glass

    NASA Astrophysics Data System (ADS)

    Inoue, Kazuyuki; Isogai, Akio

    1988-05-01

    In secondary ion mass spectrometry (SIMS) analysis of a quartz glass by means of negative ion bombardment, the effect of the negative ion current density (Ji) has been investigated. The results show that under lower Ji (<20 μA/cm2), time is required to compensate for the surface charge and the time is inversely proportional to Ji.

  6. Metabolic activity of uncultivated magnetotactic bacteria revealed by NanoSIMS

    NASA Astrophysics Data System (ADS)

    He, M.; Zhang, W.; Gu, L.; Pan, Y.; Lin, W.

    2017-12-01

    Microorganisms that exhibit magnetotaxis behavior, collectively known as the magnetotactic bacteria (MTB), are those whose motility is influenced by the Earth's magnetic field. MTB are a physiologically diverse group of bacteria with a unique feature of intracellular biomineralization of magnetosomes (Fe3O4 and/or Fe3S4) (Bazylinski et al., 2013). However, the ecophysiology of uncultivated MTB, especially those within the Nitrospirae phylum forming hundreds of bullet-shaped magnetite magnetosomes per cell, is still not well characterized (Lin et al., 2014). Nanoscale secondary ion mass spectrometry (NanoSIMS) is a powerful tool for revealing element distribution in nanometer-scale resolution, which opens exciting possibilities for the study of interactions between microorganisms and environments (Gao et al., 2016; Musat et al., 2016). Here we applied NanoSIMS to investigate the dynamics of carbon and nitrogen assimilations in two magnetotactic Nitrospirae populations at single cell level. Our NanoSIMS results confirmed the metabolic potential of Nitrospirae MTB proposed by genomic and metagenomic analysis and provided additional insights into the ecophysiology of uncultivated MTB. This study suggests that NanoSIMS-based analyses are powerful approaches for investigating and characterizing the ecological function of environmental microorganisms. References: Bazylinski D A., Lefèvre, C T., Schüler D., 2013. Magnetotactic Bacteria. 453-494.Lin W, Bazylinski DA, Xiao T, Wu L- F, Pan Y., 2014. Life with compass: diversity and biogeography of magnetotactic bacteria. Environ Microbiol, 16: 1462-2920.Gao D., Huang X., Tao Y., 2016. A critical review of NanoSIMS in analysis of microbial metabolic activities at single-cell level. Crit Rev Biotechnol, 36: 884-890.Musat N., Musat F., Weber PK., Pett-Ridge J., 2016. Tracking microbial interactions with NanoSIMS. Curr Opin Biotechnol, 41: 114-121.

  7. Development and Validation of a Monte Carlo Simulation Tool for Multi-Pinhole SPECT

    PubMed Central

    Mok, Greta S. P.; Du, Yong; Wang, Yuchuan; Frey, Eric C.; Tsui, Benjamin M. W.

    2011-01-01

    Purpose In this work, we developed and validated a Monte Carlo simulation (MCS) tool for investigation and evaluation of multi-pinhole (MPH) SPECT imaging. Procedures This tool was based on a combination of the SimSET and MCNP codes. Photon attenuation and scatter in the object, as well as penetration and scatter through the collimator detector, are modeled in this tool. It allows accurate and efficient simulation of MPH SPECT with focused pinhole apertures and user-specified photon energy, aperture material, and imaging geometry. The MCS method was validated by comparing the point response function (PRF), detection efficiency (DE), and image profiles obtained from point sources and phantom experiments. A prototype single-pinhole collimator and focused four- and five-pinhole collimators fitted on a small animal imager were used for the experimental validations. We have also compared computational speed among various simulation tools for MPH SPECT, including SimSET-MCNP, MCNP, SimSET-GATE, and GATE for simulating projections of a hot sphere phantom. Results We found good agreement between the MCS and experimental results for PRF, DE, and image profiles, indicating the validity of the simulation method. The relative computational speeds for SimSET-MCNP, MCNP, SimSET-GATE, and GATE are 1: 2.73: 3.54: 7.34, respectively, for 120-view simulations. We also demonstrated the application of this MCS tool in small animal imaging by generating a set of low-noise MPH projection data of a 3D digital mouse whole body phantom. Conclusions The new method is useful for studying MPH collimator designs, data acquisition protocols, image reconstructions, and compensation techniques. It also has great potential to be applied for modeling the collimator-detector response with penetration and scatter effects for MPH in the quantitative reconstruction method. PMID:19779896

  8. The effects of loperamide, or loperamide plus simethicone, on the distribution of gut water as assessed by MRI in a mannitol model of secretory diarrhoea.

    PubMed

    Placidi, E; Marciani, L; Hoad, C L; Napolitano, A; Garsed, K C; Pritchard, S E; Cox, E F; Costigan, C; Spiller, R C; Gowland, P A

    2012-07-01

    Loperamide (LOP) is an anti-diarrhoeal agent which is thought to act largely by slowing transit with an uncertain effect on the fluid content of the small and large bowel in humans. Adding simethicone (SIM) to LOP improves its efficacy, but the mechanism of interaction is unclear. Novel MRI techniques to assess small bowel water content (SBWC) have shown that mannitol solutions markedly increase SBWC and can be used as a model of diarrhoea. We aimed to use quantitative MRI techniques to compare the actions in the gut of LOP and LOP + SIM in a model of secretory diarrhoea using mannitol. A total of 18 healthy volunteers ingested capsules containing placebo (PLA) or 12 mg LOP or 12 mg LOP + 125 mg SIM. After 100 min they were given a drink containing 5% mannitol in 350 mL of water. They underwent baseline fasting and postprandial serial MRI scans at 45 min intervals for 4.5 h after ingesting the drink. A range of MRI sequences was acquired to image the gut. LOP and LOP + SIM significantly accelerated gastric emptying (P < 0.03) and reduced SBWC during the late phase (135-270 min after mannitol ingestion), P < 0.009, while delaying arrival of fluid in the ascending colon (AC). The relaxation time T2 of the contents of the AC was reduced by both drugs (P < 0.0001). LOP and LOP + SIM accelerate gastric emptying, but reduce small bowel water content which may contribute to the delay in oral-caecal transit and overall anti-diarrhoeal effect. © 2012 Blackwell Publishing Ltd.

  9. Sim1 is required for the migration and axonal projections of V3 interneurons in the developing mouse spinal cord.

    PubMed

    Blacklaws, Jake; Deska-Gauthier, Dylan; Jones, Christopher T; Petracca, Yanina L; Liu, Mingwei; Zhang, Han; Fawcett, James P; Glover, Joel C; Lanuza, Guillermo M; Zhang, Ying

    2015-09-01

    V3 spinal interneurons (INs) are a group of excitatory INs that play a crucial role in producing balanced and stable gaits in vertebrate animals. In the developing mouse spinal cord, V3 INs arise from the most ventral progenitor domain and form anatomically distinctive subpopulations in adult spinal cords. They are marked by the expression of transcription factor Sim1 postmitotically, but the function of Sim1 in V3 development remains unknown. Here, we used Sim1(Cre) ;tdTomato mice to trace the fate of V3 INs in a Sim1 mutant versus control genetic background during development. In Sim1 mutants, V3 INs are produced normally and maintain a similar position and organization as in wild types before E12.5. Further temporal analysis revealed that the V3 INs in the mutants failed to migrate properly to form V3 subgroups along the dorsoventral axis of the spinal cord. At birth, in the Sim1 mutant the number of V3 INs in the ventral subgroup was normal, but they were significantly reduced in the dorsal subgroup with a concomitant increase in the intermediate subgroup. Retrograde labeling at lumbar level revealed that loss of Sim1 led to a reduction in extension of contralateral axon projections both at E14.5 and P0 without affecting ipsilateral axon projections. These results demonstrate that Sim1 is essential for proper migration and the guidance of commissural axons of the spinal V3 INs. © 2015 Wiley Periodicals, Inc.

  10. PRUNE—SIM users guide.

    Treesearch

    R.D. Fight; J.M. Cahill; T.A. Snellgrove; T.D. Fahey

    1987-01-01

    PRUNE-SIM is a spreadsheet template (program) that allows users to simulate a financial analysis of pruning coast Douglas-fir (Pseudotsuga menziesii (Mirb.) Franco var. menziesii). The program estimates the increase in product value resulting from pruning the butt 17-foot log. Product recovery information is based on actual...

  11. Analysis of corneal topography in patients with pure microphthalmia in Eastern China.

    PubMed

    Hu, Pei-Hong; Gao, Gui-Ping; Yu, Yao; Pei, Chong-Gang; Zhou, Qiong; Huang, Xin; Zhang, Ying; Shao, Yi

    2015-12-01

    To determine the typical corneal changes in pure microphthalmia using a corneal topography system and identify characteristics that may assist in early diagnosis. Patients with pure microphthalmia and healthy control subjects underwent corneal topography analysis (Orbscan IIZ® Corneal Topography System; Bausch and Lomb, Bridgewater, NJ, USA) to determine degree of corneal astigmatism (mean A), simulation of corneal astigmatism (sim A), mean keratometry (mean K), simulated keratometry (sim K), irregularities in the 3 - and 5-mm zone, and mean thickness of nine distinct corneal regions. Patients with pure microphthalmia (n = 12) had significantly higher mean K, sim K, mean A, sim A, 3.0 mm irregularity and 5.0 mm irregularity, and exhibited significantly more false keratoconus than controls (n = 12). There was a significant between-group difference in the morphology of the anterior corneal surface and the central curvature of the cornea. Changes in corneal morphology observed in this study could be useful in borderline situations to confirm the diagnosis of pure microphthalmia. © The Author(s) 2015.

  12. Exploratory analysis of TOF-SIMS data from biological surfaces

    NASA Astrophysics Data System (ADS)

    Vaidyanathan, Seetharaman; Fletcher, John S.; Henderson, Alex; Lockyer, Nicholas P.; Vickerman, John C.

    2008-12-01

    The application of multivariate analytical tools enables simplification of TOF-SIMS datasets so that useful information can be extracted from complex spectra and images, especially those that do not give readily interpretable results. There is however a challenge in understanding the outputs from such analyses. The problem is complicated when analysing images, given the additional dimensions in the dataset. Here we demonstrate how the application of simple pre-processing routines can enable the interpretation of TOF-SIMS spectra and images. For the spectral data, TOF-SIMS spectra used to discriminate bacterial isolates associated with urinary tract infection were studied. Using different criteria for picking peaks before carrying out PC-DFA enabled identification of the discriminatory information with greater certainty. For the image data, an air-dried salt stressed bacterial sample, discussed in another paper by us in this issue, was studied. Exploration of the image datasets with and without normalisation prior to multivariate analysis by PCA or MAF resulted in different regions of the image being highlighted by the techniques.

  13. Understanding Earthquake Fault Systems Using QuakeSim Analysis and Data Assimilation Tools

    NASA Technical Reports Server (NTRS)

    Donnellan, Andrea; Parker, Jay; Glasscoe, Margaret; Granat, Robert; Rundle, John; McLeod, Dennis; Al-Ghanmi, Rami; Grant, Lisa

    2008-01-01

    We are using the QuakeSim environment to model interacting fault systems. One goal of QuakeSim is to prepare for the large volumes of data that spaceborne missions such as DESDynI will produce. QuakeSim has the ability to ingest distributed heterogenous data in the form of InSAR, GPS, seismicity, and fault data into various earthquake modeling applications, automating the analysis when possible. Virtual California simulates interacting faults in California. We can compare output from long time history Virtual California runs with the current state of strain and the strain history in California. In addition to spaceborne data we will begin assimilating data from UAVSAR airborne flights over the San Francisco Bay Area, the Transverse Ranges, and the Salton Trough. Results of the models are important for understanding future earthquake risk and for providing decision support following earthquakes. Improved models require this sensor web of different data sources, and a modeling environment for understanding the combined data.

  14. Elemental imaging at the nanoscale: NanoSIMS and complementary techniques for element localisation in plants.

    PubMed

    Moore, Katie L; Lombi, Enzo; Zhao, Fang-Jie; Grovenor, Chris R M

    2012-04-01

    The ability to locate and quantify elemental distributions in plants is crucial to understanding plant metabolisms, the mechanisms of uptake and transport of minerals and how plants cope with toxic elements or elemental deficiencies. High-resolution secondary ion mass spectrometry (SIMS) is emerging as an important technique for the analysis of biological material at the subcellular scale. This article reviews recent work using the CAMECA NanoSIMS to determine elemental distributions in plants. The NanoSIMS is able to map elemental distributions at high resolution, down to 50 nm, and can detect very low concentrations (milligrams per kilogram) for some elements. It is also capable of mapping almost all elements in the periodic table (from hydrogen to uranium) and can distinguish between stable isotopes, which allows the design of tracer experiments. In this review, particular focus is placed upon studying the same or similar specimens with both the NanoSIMS and a wide range of complementary techniques, showing how the advantages of each technique can be combined to provide a fuller data set to address complex scientific questions. Techniques covered include optical microscopy, synchrotron techniques, including X-ray fluorescence and X-ray absorption spectroscopy, transmission electron microscopy, electron probe microanalysis, particle-induced X-ray emission and inductively coupled plasma mass spectrometry. Some of the challenges associated with sample preparation of plant material for SIMS analysis, the artefacts and limitations of the technique and future trends are also discussed.

  15. Scalable and Axiomatic Ranking of Network Role Similarity

    PubMed Central

    Jin, Ruoming; Lee, Victor E.; Li, Longjie

    2014-01-01

    A key task in analyzing social networks and other complex networks is role analysis: describing and categorizing nodes according to how they interact with other nodes. Two nodes have the same role if they interact with equivalent sets of neighbors. The most fundamental role equivalence is automorphic equivalence. Unfortunately, the fastest algorithms known for graph automorphism are nonpolynomial. Moreover, since exact equivalence is rare, a more meaningful task is measuring the role similarity between any two nodes. This task is closely related to the structural or link-based similarity problem that SimRank addresses. However, SimRank and other existing similarity measures are not sufficient because they do not guarantee to recognize automorphically or structurally equivalent nodes. This paper makes two contributions. First, we present and justify several axiomatic properties necessary for a role similarity measure or metric. Second, we present RoleSim, a new similarity metric which satisfies these axioms and which can be computed with a simple iterative algorithm. We rigorously prove that RoleSim satisfies all these axiomatic properties. We also introduce Iceberg RoleSim, a scalable algorithm which discovers all pairs with RoleSim scores above a user-defined threshold θ. We demonstrate the interpretative power of RoleSim on both both synthetic and real datasets. PMID:25383066

  16. An orientation analysis method for protein immobilized on quantum dot particles

    NASA Astrophysics Data System (ADS)

    Aoyagi, Satoka; Inoue, Masae

    2009-11-01

    The evaluation of orientation of biomolecules immobilized on nanodevices is crucial for the development of high performance devices. Such analysis requires ultra high sensitivity so as to be able to detect less than one molecular layer on a device. Time-of-flight secondary ion mass spectrometry (TOF-SIMS) has sufficient sensitivity to evaluate the uppermost surface structure of a single molecular layer. The objective of this study is to develop an orientation analysis method for proteins immobilized on nanomaterials such as quantum dot particles, and to evaluate the orientation of streptavidin immobilized on quantum dot particles by means of TOF-SIMS. In order to detect fragment ions specific to the protein surface, a monoatomic primary ion source (Ga +) and a cluster ion source (Au 3+) were employed. Streptavidin-immobilized quantum dot particles were immobilized on aminosilanized ITO glass plates at amino groups by covalent bonding. The reference samples streptavidin directly immobilized on ITO plates were also prepared. All samples were dried with a freeze dryer before TOF-SIMS measurement. The positive secondary ion spectra of each sample were obtained using TOF-SIMS with Ga + and Au 3+, respectively, and then they were compared so as to characterize each sample and detect the surface structure of the streptavidin immobilized with the biotin-immobilized quantum dots. The chemical structures of the upper surface of the streptavidin molecules immobilized on the quantum dot particles were evaluated with TOF-SIMS spectra analysis. The indicated surface side of the streptavidin molecules immobilized on the quantum dots includes the biotin binding site.

  17. SU-F-303-12: Implementation of MR-Only Simulation for Brain Cancer: A Virtual Clinical Trial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glide-Hurst, C; Zheng, W; Kim, J

    2015-06-15

    Purpose: To perform a retrospective virtual clinical trial using an MR-only workflow for a variety of brain cancer cases by incorporating novel imaging sequences, tissue segmentation using phase images, and an innovative synthetic CT (synCT) solution. Methods: Ten patients (16 lesions) were evaluated using a 1.0T MR-SIM including UTE-DIXON imaging (TE = 0.144/3.4/6.9ms). Bone-enhanced images were generated from DIXON-water/fat and inverted UTE. Automated air segmentation was performed using unwrapped UTE phase maps. Segmentation accuracy was assessed by calculating intersection and Dice similarity coefficients (DSC) using CT-SIM as ground truth. SynCTs were generated using voxel-based weighted summation incorporating T2, FLAIR, UTE1,more » and bone-enhanced images. Mean absolute error (MAE) characterized HU differences between synCT and CT-SIM. Dose was recalculated on synCTs; differences were quantified using planar gamma analysis (2%/2 mm dose difference/distance to agreement) at isocenter. Digitally reconstructed radiographs (DRRs) were compared. Results: On average, air maps intersected 80.8 ±5.5% (range: 71.8–88.8%) between MR-SIM and CT-SIM yielding DSCs of 0.78 ± 0.04 (range: 0.70–0.83). Whole-brain MAE between synCT and CT-SIM was 160.7±8.8 HU, with the largest uncertainty arising from bone (MAE = 423.3±33.2 HU). Gamma analysis revealed pass rates of 99.4 ± 0.04% between synCT and CT-SIM for the cohort. Dose volume histogram analysis revealed that synCT tended to yield slightly higher doses. Organs at risk such as the chiasm and optic nerves were most sensitive due to their proximities to air/bone interfaces. DRRs generated via synCT and CT-SIM were within clinical tolerances. Conclusion: Our approach for MR-only simulation for brain cancer treatment planning yielded clinically acceptable results relative to the CT-based benchmark. While slight dose differences were observed, reoptimization of treatment plans and improved image registration can address this limitation. Future work will incorporate automated registration between setup images (cone-beam CT and kilovoltage images) for synCT and CT-SIM. Submitting institution holds research agreements with Philips HealthCare, Best, Netherlands and Varian Medical Systems, Palo Alto, CA. Research partially sponsored via an Internal Mentored Research Grant.« less

  18. SIMS analyses of minor and trace element distributions in fracture calcite from Yucca Mountain, Nevada, USA

    NASA Astrophysics Data System (ADS)

    Denniston, Rhawn F.; Shearer, Charles K.; Layne, Graham D.; Vaniman, David T.

    1997-05-01

    Fracture-lining calcite samples from Yucca Mountain, Nevada, obtained as part of the extensive vertical sampling in studies of this site as a potential high-level waste repository, have been characterized according to microbeam-scale (25-30 μm) trace and minor element chemistry, and cathodoluminescent zonation patterns. As bulk chemical analyses are limited in spatial resolution and are subject to contamination by intergrown phases, a technique for analysis by secondary ion mass spectrometry (SIMS) of minor (Mn, Fe, Sr) and trace (REE) elements in calcite was developed and applied to eighteen calcite samples from four boreholes and one trench. SIMS analyses of REE in calcite and dolomite have been shown to be quantitative to abundances < 1 × chondrite. Although the low secondary ion yields associated with carbonates forced higher counting times than is necessary in most silicates, Mn, Fe, Sr, and REE analyses were obtained with sub-ppm detection limits and 2-15% analytical precision. Bulk chemical signatures noted by Vaniman (1994) allowed correlation of minor and trace element signatures in Yucca Mountain calcite with location of calcite precipitation (saturated vs. unsaturated zone). For example, upper unsaturated zone calcite exhibits pronounced negative Ce and Eu anomalies not observed in calcite collected below in the deep unsaturated zone. These chemical distinctions served as fingerprints which were applied to growth zones in order to examine temporal changes in calcite crystallization histories; analyses of such fine-scale zonal variations are unattainable using bulk analytical techniques. In addition, LREE (particularly Ce) scavenging of calcite-precipitating solutions by manganese oxide phases is discussed as the mechanism for Ce-depletion in unsaturated zone calcite.

  19. Modeling and performance data for heaving bouy wave energy converter with a compressible degree of freedom

    DOE Data Explorer

    Bacelli, Giorgio

    2016-09-28

    Modeling and performance data in Matlab data file (.mat) containing 3 structures (WEC model, simRes_sr and simRes_fix), and a pdf document describing the model, the simulations, and the analysis that has been carried out.

  20. The Use of 3D Telomere FISH for the Characterization of the Nuclear Architecture in EBV-Positive Hodgkin's Lymphoma.

    PubMed

    Knecht, Hans; Mai, Sabine

    2017-01-01

    The 3D nuclear architecture is closely related to cellular functions and chromosomes are organized in distinct territories. Quantitative 3D telomere FISH analysis (3D Q-FISH) and 3D super-resolution imaging (3D-SIM) at a resolution up to 80 nm as well as the recently developed combined quantitative 3D TRF2-telomere immune FISH technique (3D TRF2/Telo-Q-FISH) have substantially contributed to elucidate molecular pathogenic mechanisms of hematological diseases. Here we report the methods we applied to uncover major molecular steps involved in the pathogenesis of EBV-associated Hodgkin's lymphoma. These methods allowed us to identify the EBV-encoded oncoprotein LMP1 as a key element in the formation of Hodgkin (H-cell) and multinucleated Reed-Sternberg cells (RS-cell), the diagnostic tumor cell of classical Hodgkin's lymphoma (cHL). LMP1 mediates multinuclearity through downregulation of shelterin proteins, in particular telomere repeat binding factor 2 (TRF2).

  1. Late Eocene to middle Miocene (33 to 13 million years ago) vegetation and climate development on the North American Atlantic Coastal Plain (IODP Expedition 313, Site M0027)

    NASA Astrophysics Data System (ADS)

    Kotthoff, U.; Greenwood, D. R.; McCarthy, F. M. G.; Müller-Navarra, K.; Prader, S.; Hesselbo, S. P.

    2014-08-01

    We investigated the palynology of sediment cores from Site M0027 of IODP (Integrated Ocean Drilling Program) Expedition 313 on the New Jersey shallow shelf to examine vegetation and climate dynamics on the east coast of North America between 33 and 13 million years ago and to assess the impact of over-regional climate events on the region. Palynological results are complemented with pollen-based quantitative climate reconstructions. Our results indicate that the hinterland vegetation of the New Jersey shelf was characterized by oak-hickory forests in the lowlands and conifer-dominated vegetation in the highlands from the early Oligocene to the middle Miocene. The Oligocene witnessed several expansions of conifer forest, probably related to cooling events. The pollen-based climate data imply an increase in annual temperatures from ∼11.5 °C to more than 16 °C during the Oligocene. The Mi-1 cooling event at the onset of the Miocene is reflected by an expansion of conifers and mean annual temperature decrease of ∼4 °C, from ∼16 °C to ∼12 °C around 23 million years before present. Relatively low annual temperatures are also recorded for several samples during an interval around ∼20 million years before present, which may reflect the Mi-1a and the Mi-1aa cooling events. Generally, the Miocene ecosystem and climate conditions were very similar to those of the Oligocene. Miocene grasslands, as known from other areas in the USA during that time period, are not evident for the hinterland of the New Jersey shelf, possibly reflecting moisture from the proto-Gulf Stream. The palaeovegetation data reveal stable conditions during the mid-Miocene climatic optimum at ∼15 million years before present, with only a minor increase in deciduous-evergreen mixed forest taxa and a decrease in swamp forest taxa. Pollen-based annual temperature reconstructions show average annual temperatures of ∼14 °C during the mid-Miocene climatic optimum, ∼2 °C higher than today, but ∼1.5 °C lower than preceding and following phases of the Miocene. We conclude that vegetation and regional climate in the hinterland of the New Jersey shelf did not react as sensitively to Oligocene and Miocene climate changes as other regions in North America or Europe due to the moderating effects of the North Atlantic. An additional explanation for the relatively low regional temperatures reconstructed for the mid-Miocene climatic optimum could be an uplift of the Appalachian Mountains during the Miocene, which would also have influenced the catchment area of our pollen record.

  2. SimLabel: a graphical user interface to simulate continuous wave EPR spectra from site-directed spin labeling experiments.

    PubMed

    Etienne, E; Le Breton, N; Martinho, M; Mileo, E; Belle, V

    2017-08-01

    Site-directed spin labeling (SDSL) combined with continuous wave electron paramagnetic resonance (cw EPR) spectroscopy is a powerful technique to reveal, at the residue level, structural transitions in proteins. SDSL-EPR is based on the selective grafting of a paramagnetic label on the protein under study, followed by cw EPR analysis. To extract valuable quantitative information from SDSL-EPR spectra and thus give reliable interpretation on biological system dynamics, numerical simulations of the spectra are required. Such spectral simulations can be carried out by coding in MATLAB using functions from the EasySpin toolbox. For non-expert users of MATLAB, this could be a complex task or even impede the use of such simulation tool. We developed a graphical user interface called SimLabel dedicated to run cw EPR spectra simulations particularly coming from SDSL-EPR experiments. Simlabel provides an intuitive way to visualize, simulate, and fit such cw EPR spectra. An example of SDSL-EPR spectra simulation concerning the study of an intrinsically disordered region undergoing a local induced folding is described and discussed. We believe that this new tool will help the users to rapidly obtain reliable simulated spectra and hence facilitate the interpretation of their results. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  3. Autotrophic and heterotrophic acquisition of carbon and nitrogen by a mixotrophic chrysophyte established through stable isotope analysis.

    PubMed

    Terrado, Ramon; Pasulka, Alexis L; Lie, Alle A-Y; Orphan, Victoria J; Heidelberg, Karla B; Caron, David A

    2017-09-01

    Collectively, phagotrophic algae (mixotrophs) form a functional continuum of nutritional modes between autotrophy and heterotrophy, but the specific physiological benefits of mixotrophic nutrition differ among taxa. Ochromonas spp. are ubiquitous chrysophytes that exhibit high nutritional flexibility, although most species generally fall towards the heterotrophic end of the mixotrophy spectrum. We assessed the sources of carbon and nitrogen in Ochromonas sp. strain BG-1 growing mixotrophically via short-term stable isotope probing. An axenic culture was grown in the presence of either heat-killed bacteria enriched with 15 N and 13 C, or unlabeled heat-killed bacteria and labeled inorganic substrates ( 13 C-bicarbonate and 15 N-ammonium). The alga exhibited high growth rates (up to 2 divisions per day) only until heat-killed bacteria were depleted. NanoSIMS and bulk IRMS isotope analyses revealed that Ochromonas obtained 84-99% of its carbon and 88-95% of its nitrogen from consumed bacteria. The chrysophyte assimilated inorganic 13 C-carbon and 15 N-nitrogen when bacterial abundances were very low, but autotrophic (photosynthetic) activity was insufficient to support net population growth of the alga. Our use of nanoSIMS represents its first application towards the study of a mixotrophic alga, enabling a better understanding and quantitative assessment of carbon and nutrient acquisition by this species.

  4. The genomes of four novel begomoviruses and a new Sida micrantha mosaic virus strain from Bolivian weeds.

    PubMed

    Wyant, Patrícia Soares; Gotthardt, Diether; Schäfer, Benjamin; Krenz, Björn; Jeske, Holger

    2011-02-01

    Begomovirus is the largest genus within the family Geminiviridae and includes economically important plant DNA viruses infecting a broad range of plant species and causing devastating crop diseases, mainly in subtropical and tropical countries. Besides cultivated plants, many weeds act as virus reservoirs. Eight begomovirus isolates from Bolivian weeds were examined using rolling-circle amplification (RCA) and restriction fragment length polymorphism (RFLP). An efficient, novel cloning strategy using limited Sau3A digestion to obtain tandem-repeat inserts allowed the sequencing of the complete genomes. The viruses were classified by phylogenetic analysis as typical bipartite New World begomoviruses. Four of them represented distinct new virus species, for which the names Solanum mosaic Bolivia virus, Sida mosaic Bolivia virus 1, Sida mosaic Bolivia virus 2, and Abutilon mosaic Bolivia virus are proposed. Three were variants of a new strain of Sida micrantha mosaic virus (SimMV), SimMV-rho[BoVi07], SimMV-rho[Bo:CF1:07] and SimMV-rho[Bo:CF2:07], and one was a new variant of a previously described SimMV, SimMV-MGS2:07-Bo.

  5. Application of wide selected-ion monitoring data-independent acquisition to identify tomato fruit proteins regulated by the CUTIN DEFICIENT2 transcription factor.

    PubMed

    Martin, Laetitia B B; Sherwood, Robert W; Nicklay, Joshua J; Yang, Yong; Muratore-Schroeder, Tara L; Anderson, Elizabeth T; Thannhauser, Theodore W; Rose, Jocelyn K C; Zhang, Sheng

    2016-08-01

    We describe here the use of label-free wide selected-ion monitoring data-independent acquisition (WiSIM-DIA) to identify proteins that are involved in the formation of tomato (Solanum lycopersicum) fruit cuticles and that are regulated by the transcription factor CUTIN DEFICIENT2 (CD2). A spectral library consisting of 11 753 unique peptides, corresponding to 2338 tomato protein groups, was used and the DIA analysis was performed at the MS1 level utilizing narrow mass windows for extraction with Skyline 2.6 software. We identified a total of 1140 proteins, 67 of which had expression levels that differed significantly between the cd2 tomato mutant and the wild-type cultivar M82. Differentially expressed proteins including a key protein involved in cutin biosynthesis, were selected for validation by target SRM/MRM and by Western blot analysis. In addition to confirming a role for CD2 in regulating cuticle formation, the results also revealed that CD2 influences pathways associated with cell wall biology, anthocyanin biosynthesis, plant development, and responses to stress, which complements findings of earlier RNA-Seq experiments. Our results provide new insights into molecular processes and aspects of fruit biology associated with CD2 function, and demonstrate that the WiSIM-DIA is an effective quantitative approach for global protein identifications. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Correlating microscopy techniques and ToF-SIMS analysis of fully grown mammalian oocytes.

    PubMed

    Gulin, Alexander; Nadtochenko, Victor; Astafiev, Artyom; Pogorelova, Valentina; Rtimi, Sami; Pogorelov, Alexander

    2016-06-20

    The 2D-molecular thin film analysis protocol for fully grown mice oocytes is described using an innovative approach. Time-of-flight secondary ion mass spectrometry (ToF-SIMS), scanning electron microscopy (SEM), atomic force microscopy (AFM) and optical microscopy imaging were applied to the same mice oocyte section on the same sample holder. A freeze-dried mice oocyte was infiltrated into embedding media, e.g. Epon, and then was cut with a microtome and 2 μm thick sections were transferred onto an ITO coated conductive glass. Mammalian oocytes can contain "nucleolus-like body" (NLB) units and ToF-SIMS analysis was used to investigate the NLB composition. The ion-spatial distribution in the cell components was identified and compared with the images acquired by SEM, AFM and optical microscopy. This study presents a significant advancement in cell embryology, cell physiology and cancer-cell biochemistry.

  7. Specimen preparation for NanoSIMS analysis of biological materials

    NASA Astrophysics Data System (ADS)

    Grovenor, C. R. M.; Smart, K. E.; Kilburn, M. R.; Shore, B.; Dilworth, J. R.; Martin, B.; Hawes, C.; Rickaby, R. E. M.

    2006-07-01

    In order to achieve reliable and reproducible analysis of biological materials by SIMS, it is critical both that the chosen specimen preparation method does not modify substantially the in vivo chemistry that is the focus of the study and that any chemical information obtained can be calibrated accurately by selection of appropriate standards. In Oxford, we have been working with our new Cameca NanoSIMS50 on two very distinct classes of biological materials; the first where the sample preparation problems are relatively undemanding - human hair - but calibration for trace metal analysis is a critical issue and, the second, marine coccoliths and hyperaccumulator plants where reliable specimen preparation by rapid freezing and controlled drying to preserve the distribution of diffusible species is the first and most demanding requirement, but worthwhile experiments on tracking key elements can still be undertaken even when it is clear that some redistribution of the most diffusible ions has occurred.

  8. Evaluation of C60 secondary ion mass spectrometry for the chemical analysis and imaging of fingerprints.

    PubMed

    Sisco, Edward; Demoranville, Leonard T; Gillen, Greg

    2013-09-10

    The feasibility of using C60(+) cluster primary ion bombardment secondary ion mass spectrometry (C60(+) SIMS) for the analysis of the chemical composition of fingerprints is evaluated. It was found that C60(+) SIMS could be used to detect and image the spatial localization of a number of sebaceous and eccrine components in fingerprints. These analyses were also found to not be hindered by the use of common latent print powder development techniques. Finally, the ability to monitor the depth distribution of fingerprint constituents was found to be possible - a capability which has not been shown using other chemical imaging techniques. This paper illustrates a number of strengths and potential weaknesses of C60(+) SIMS as an additional or complimentary technique for the chemical analysis of fingerprints. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. High resolution isotopic analysis of U-bearing particles via fusion of SIMS and EDS images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tarolli, Jay G.; Naes, Benjamin E.; Garcia, Benjamin J.

    Image fusion of secondary ion mass spectrometry (SIMS) images and X-ray elemental maps from energy-dispersive spectroscopy (EDS) was performed to facilitate the isolation and re-analysis of isotopically unique U-bearing particles where the highest precision SIMS measurements are required. Image registration, image fusion and particle micromanipulation were performed on a subset of SIMS images obtained from a large area pre-screen of a particle distribution from a sample containing several certified reference materials (CRM) U129A, U015, U150, U500 and U850, as well as a standard reference material (SRM) 8704 (Buffalo River Sediment) to simulate particles collected on swipes during routine inspections ofmore » declared uranium enrichment facilities by the International Atomic Energy Agency (IAEA). In total, fourteen particles, ranging in size from 5 – 15 µm, were isolated and re-analyzed by SIMS in multi-collector mode identifying nine particles of CRM U129A, one of U150, one of U500 and three of U850. These identifications were made within a few percent errors from the National Institute of Standards and Technology (NIST) certified atom percent values for 234U, 235U and 238U for the corresponding CRMs. This work represents the first use of image fusion to enhance the accuracy and precision of isotope ratio measurements for isotopically unique U-bearing particles for nuclear safeguards applications. Implementation of image fusion is essential for the identification of particles of interests that fall below the spatial resolution of the SIMS images.« less

  10. Comparison of methods for extraction of ethyl carbamate from alcoholic beverages in gas chromatography/mass spectrometry analysis.

    PubMed

    Mirzoian, Armen; Mabud, Abdul

    2006-01-01

    A procedure to analyze ethyl carbamate (EC) by gas chromatography/mass spectrometry was optimized and validated. Deuterated EC (d5-EC) was added to the samples as an internal standard followed by extraction with polystyrene crosslinked polystyrene cartridges using minimal volumes of ethyl acetate. The EC response was measured in selective ion monitoring (SIM) mode and found to be linear in the range between the limit of quantitation (10 micro/L) and 1000 microg/L. EC recoveries varied from 92 to 112%, with the average value of 100 +/- 8%. The procedure compared well (r2 = 0.9970) with the existing AOAC Official Method with the added benefits of minimal solvent usage and reduced matrix interferences.

  11. Quantification issues of trace metal contaminants on silicon wafers by means of TOF-SIMS, ICP-MS, and TXRF

    NASA Astrophysics Data System (ADS)

    Rostam-Khani, P.; Hopstaken, M. J. P.; Vullings, P.; Noij, G.; O'Halloran, O.; Claassen, W.

    2004-06-01

    Measurement of surface metal contamination on silicon wafers is essential for yield enhancement in IC manufacturing. Vapor phase decomposition coupled with either inductively coupled plasma mass spectrometry (VPD-ICP-MS), or total reflection X-ray fluorescence (VPD-TXRF), TXRF and more recently time of flight secondary ion mass spectrometry (TOF-SIMS) are used to monitor surface metal contamination. These techniques complement each other in their respective strengths and weaknesses. For reliable and accurate quantification, so-called relative sensitivity factors (RSF) are required for TOF-SIMS analysis. For quantification purposes in VPD, the collection efficiency (CE) is important to ensure complete collection of contamination. A standard procedure has been developed that combines the determination of these RSFs as well as the collection efficiency using all the analytical techniques mentioned above. Therefore, sample wafers were intentionally contaminated and analyzed (by TOF-SIMS) directly after preparation. After VPD-ICP-MS, several scanned surfaces were analyzed again by TOF-SIMS. Comparing the intensities of the specific metals before and after the VPD-DC procedure on the scanned surface allows the determination of so-called removing efficiency (RE). In general, very good agreement was obtained comparing the four analytical techniques after updating the RSFs for TOF-SIMS. Progress has been achieved concerning the CE evaluation as well as determining the RSFs more precisely for TOF-SIMS.

  12. NanoSIMS Analyses of Mo Indicate Nitrogenase Activity and Help Solve a N and C Fixation Puzzle in a Marine Cyanobacterium

    NASA Astrophysics Data System (ADS)

    Pett-Ridge, J.; Weber, P. K.; Finzi, J.; Hutcheon, I. D.; Capone, D. G.

    2006-12-01

    Diazotrophic cyanobacteria are capable of both CO2 and N2 fixation, yet must separate these two functions because the nitrogenase enzymes used in N2 fixation are strongly inhibited by O2 produced during photosynthesis. Some lineages, such as Anabaena, use specialized cells (heterocysts) to maintain functional segregation. However the mechanism of this segregation is poorly understood in Trichodesmium, a critical component of marine primary production in the tropical and subtropical North Atlantic. While some Trichodesmium studies suggest a temporal segregation of the nitrogen and carbon fixing processes, others indicate nitrogen fixation is spatially isolated in differentiated cells called diazocytes. In order to isolate the intracellular location of N fixation in both species, we used a combination of TEM, SEM and NanoSIMS analysis to map the distribution of C, N and Mo (a critical nitrogenase co-factor) isotopes in intact cells. NanoSIMS is a powerful surface analysis tool which combines nanometer-scale imaging resolution with the high sensitivity of mass spectrometry. Using cells grown in a 13CO^2 and 15N2 enriched atmosphere, our analyses indicate that in Anabaena, heterocysts are consistently enriched in Mo, and Mo accumulation suggests active N fixation (as opposed to N storage). In the non- heterocystous Trichodesmium, Mo is concentrated in sub-regions of individual cells, and is not associated with regions of N storage (cyanophycin granules). We suggest that NanoSIMS mapping of metal enzyme co- factors is a unique method of identifying physiological and morphological characteristics within individual bacterial cells. This combination of NanoSIMS analysis and high resolution microscopy allows isotopic analysis to be linked to morphological features and holds great promise for fine-scale studies of bacteria metabolism.

  13. Time of flight secondary ion mass spectrometry of bone—Impact of sample preparation and measurement conditions

    PubMed Central

    Henss, Anja; Hild, Anne; Rohnke, Marcus; Wenisch, Sabine; Janek, Juergen

    2015-01-01

    Time of flight secondary ion mass spectrometry (ToF-SIMS) enables the simultaneous detection of organic and inorganic ions and fragments with high mass and spatial resolution. Due to recent technical developments, ToF-SIMS has been increasingly applied in the life sciences where sample preparation plays an eminent role for the quality of the analytical results. This paper focusses on sample preparation of bone tissue and its impact on ToF-SIMS analysis. The analysis of bone is important for the understanding of bone diseases and the development of replacement materials and new drugs for the cure of diseased bone. The main purpose of this paper is to find out which preparation process is best suited for ToF-SIMS analysis of bone tissue in order to obtain reliable and reproducible analytical results. The influence of the embedding process on the different components of bone is evaluated using principal component analysis. It is shown that epoxy resin as well as methacrylate based plastics (Epon and Technovit) as embedding materials do not infiltrate the mineralized tissue and that cut sections are better suited for the ToF-SIMS analysis than ground sections. In case of ground samples, a resin layer is smeared over the sample surface due to the polishing step and overlap of peaks is found. Beside some signals of fatty acids in the negative ion mode, the analysis of native, not embedded samples does not provide any advantage. The influence of bismuth bombardment and O2 flooding on the signal intensity of organic and inorganic fragments due to the variation of the ionization probability is additionally discussed. As C60 sputtering has to be applied to remove the smeared resin layer, its effect especially on the organic fragments of the bone is analyzed and described herein. PMID:26253108

  14. Time of flight secondary ion mass spectrometry of bone-Impact of sample preparation and measurement conditions.

    PubMed

    Henss, Anja; Hild, Anne; Rohnke, Marcus; Wenisch, Sabine; Janek, Juergen

    2015-06-07

    Time of flight secondary ion mass spectrometry (ToF-SIMS) enables the simultaneous detection of organic and inorganic ions and fragments with high mass and spatial resolution. Due to recent technical developments, ToF-SIMS has been increasingly applied in the life sciences where sample preparation plays an eminent role for the quality of the analytical results. This paper focusses on sample preparation of bone tissue and its impact on ToF-SIMS analysis. The analysis of bone is important for the understanding of bone diseases and the development of replacement materials and new drugs for the cure of diseased bone. The main purpose of this paper is to find out which preparation process is best suited for ToF-SIMS analysis of bone tissue in order to obtain reliable and reproducible analytical results. The influence of the embedding process on the different components of bone is evaluated using principal component analysis. It is shown that epoxy resin as well as methacrylate based plastics (Epon and Technovit) as embedding materials do not infiltrate the mineralized tissue and that cut sections are better suited for the ToF-SIMS analysis than ground sections. In case of ground samples, a resin layer is smeared over the sample surface due to the polishing step and overlap of peaks is found. Beside some signals of fatty acids in the negative ion mode, the analysis of native, not embedded samples does not provide any advantage. The influence of bismuth bombardment and O2 flooding on the signal intensity of organic and inorganic fragments due to the variation of the ionization probability is additionally discussed. As C60 sputtering has to be applied to remove the smeared resin layer, its effect especially on the organic fragments of the bone is analyzed and described herein.

  15. NanoSIMS Reveals New Structural and Elemental Signatures of Early Life

    NASA Technical Reports Server (NTRS)

    Oehler, Dorothy Z.; Mostefaoui, Smail; Meibom, Anders; Selo, Madeleine; Robert, Francois; McKay, David S.

    2006-01-01

    The young technology of NanoSIMS is unlocking new information from organic matter in ancient sediments. We have used this technique to characterize sub-micron scale element composition of Proterozoic organics that are clearly biogenic as a guide for interpreting problematic structures in terrestrial or extraterrestrial samples. We used the NanoSIMS 50 of the National Museum of Natural History in Paris to map carbon, nitrogen (as CN), and sulfur in organic structures from the approximately 0.8 Ga Bitter Springs Formation. We analyzed spheroidal and filamentous microfossils as well as organic laminae that appeared amorphous by optical and scanning electron microscopy. In clear-cut microfossils, a coincidence between optical images and NanoSIMS element maps suggests a biological origin for the mapped carbon, sulfur, and nitrogen; this conclusion is supported by high resolution NanoSIMS maps showing identical spatial distributions of C, CN and S. High resolution images also demonstrate distinctive nano structure of the filaments and spheroids. In the amorphous laminae, NanoSIMS reveals morphologies reminiscent of compressed microfossils. Distinct CN/C ratios of the spheroids, filaments, and laminae may reflect their biological precursors (cell walls, cyanobacterial sheaths, and microbial communities/biofilms, respectively). Similar amorphous laminae comprise a preponderance of the organic matter in many Precambrian deposits. Thus it is possible that NanoSIMS will provide fresh insight into a large body of previously uninterpretable material. Additionally, NanoSIMS analysis may establish new biosignatures that will be helpful for assessing the origin and biogenicity of controversial Archean structures and any organic materials that may occur in Martian or other extraterrestrial samples.

  16. Spectral iterative method and convergence analysis for solving nonlinear fractional differential equation

    NASA Astrophysics Data System (ADS)

    Yarmohammadi, M.; Javadi, S.; Babolian, E.

    2018-04-01

    In this study a new spectral iterative method (SIM) based on fractional interpolation is presented for solving nonlinear fractional differential equations (FDEs) involving Caputo derivative. This method is equipped with a pre-algorithm to find the singularity index of solution of the problem. This pre-algorithm gives us a real parameter as the index of the fractional interpolation basis, for which the SIM achieves the highest order of convergence. In comparison with some recent results about the error estimates for fractional approximations, a more accurate convergence rate has been attained. We have also proposed the order of convergence for fractional interpolation error under the L2-norm. Finally, general error analysis of SIM has been considered. The numerical results clearly demonstrate the capability of the proposed method.

  17. Recent advances in secondary ion mass spectrometry of solid acid catalysts: large zeolite crystals under bombardment.

    PubMed

    Hofmann, Jan P; Rohnke, Marcus; Weckhuysen, Bert M

    2014-03-28

    This Perspective aims to inform the heterogeneous catalysis and materials science community about the recent advances in Time-of-Flight-Secondary Ion Mass Spectrometry (ToF-SIMS) to characterize catalytic solids by taking large model H-ZSM-5 zeolite crystals as a showcase system. SIMS-based techniques have been explored in the 1980-1990's to study porous catalyst materials but, due to their limited spectral and spatiotemporal resolution, there was no real major breakthrough at that time. The technical advancements in SIMS instruments, namely improved ion gun design and new mass analyser concepts, nowadays allow for a much more detailed analysis of surface species relevant to catalytic action. Imaging with high mass and lateral resolution, determination of fragment ion patterns, novel sputter ion concepts as well as new mass analysers (e.g. ToF, FTICR) are just a few novelties, which will lead to new fundamental insight from SIMS analysis of heterogeneous catalysts. The Perspective article ends with an outlook on instrumental innovations and their potential use for catalytic systems other than zeolite crystals.

  18. Hybrid Simulator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trujillo, David J.; Sridharan, Srikesh; Weinstock, Irvin

    HybSim (short for Hybrid Simulator) is a flexible, easy to use screening tool that allows the user to quanti the technical and economic benefits of installing a village hybrid generating system and simulates systems with any combination of —Diesel generator sets —Photovoltaic arrays -Wind Turbines and -Battery energy storage systems Most village systems (or small population sites such as villages, remote military bases, small communities, independent or isolated buildings or centers) depend on diesel generation systems for their source of energy. HybSim allows the user to determine other "sources" of energy that can greatly reduce the dollar to kilo-watt hourmore » ratio. Supported by the DOE, Energy Storage Program, HybSim was initially developed to help analyze the benefits of energy storage systems in Alaskan villages. Soon after its development, other sources of energy were added providing the user with a greater range of analysis opportunities and providing the village with potentially added savings. In addition to village systems, HybSim has generated interest for use from military institutions in energy provisions and USAID for international village analysis.« less

  19. Anticipatory Water Management in Phoenix using Advanced Scenario Planning and Analyses: WaterSim 5

    NASA Astrophysics Data System (ADS)

    Sampson, D. A.; Quay, R.; White, D. D.; Gober, P.; Kirkwood, C.

    2013-12-01

    Complexity, uncertainty, and variability are inherent properties of linked social and natural processes; sustainable resource management must somehow consider all three. Typically, a decision support tool (using scenario analyses) is used to examine management alternatives under suspected trajectories in driver variables (i.e., climate forcing's, growth or economic projections, etc.). This traditional planning focuses on a small set of envisioned scenarios whose outputs are compared against one-another in order to evaluate their differing impacts on desired metrics. Human cognition typically limits this to three to five scenarios. However, complex and highly uncertain issues may require more, often much more, than five scenarios. In this case advanced scenario analysis provides quantitative or qualitative methods that can reveal patterns and associations among scenario metrics for a large ensemble of scenarios. From this analysis, then, a smaller set of heuristics that describe the complexity and uncertainty revealed provides a basis to guide planning in an anticipatory fashion. Our water policy and management model, termed WaterSim, permits advanced scenario planning and analysis for the Phoenix Metropolitan Area. In this contribution we examine the concepts of advanced scenario analysis on a large scale ensemble of scenarios using our work with WaterSim as a case study. For this case study we created a range of possible water futures by creating scenarios that encompasses differences in water supplies (our surrogates for climate change, drought, and inherent variability in riverine flows), population growth, and per capital water consumption. We used IPCC estimates of plausible, future, alterations in riverine runoff, locally produced and vetted estimates of population growth projections, and empirical trends in per capita water consumption for metropolitan cities. This ensemble consisted of ~ 30, 700 scenarios (~575 k observations). We compared and contrasted two metropolitan communities that exhibit differing growth projections and water portfolios; moderate growth with a diverse portfolio versus high growth for a more restrictive portfolio. Results illustrate that both communities exhibited an expanding envelope of possible, future water outcomes with rational water management trajectories. However, a more diverse portfolio resulted in a broad, time-insensitive decision space for management interventions. The reverse was true for the more restrictive water portfolio with high growth projections.

  20. Verification of RRA and CMC in OpenSim

    NASA Astrophysics Data System (ADS)

    Ieshiro, Yuma; Itoh, Toshiaki

    2013-10-01

    OpenSim is the free software that can handle various analysis and simulation of skeletal muscle dynamics with PC. This study treated RRA and CMC tools in OpenSim. It is remarkable that we can simulate human motion with respect to nerve signal of muscles using these tools. However, these tools seem to still in developmental stages. In order to verify applicability of these tools, we analyze bending and stretching motion data which are obtained from motion capture device using these tools. In this study, we checked the consistency between real muscle behavior and numerical results from these tools.

  1. HepSim: A repository with predictions for high-energy physics experiments

    DOE PAGES

    Chekanov, S. V.

    2015-02-03

    A file repository for calculations of cross sections and kinematic distributions using Monte Carlo generators for high-energy collisions is discussed. The repository is used to facilitate effective preservation and archiving of data from theoretical calculations and for comparisons with experimental data. The HepSim data library is publicly accessible and includes a number of Monte Carlo event samples with Standard Model predictions for current and future experiments. The HepSim project includes a software package to automate the process of downloading and viewing online Monte Carlo event samples. Data streaming over a network for end-user analysis is discussed.

  2. Using time-of-flight secondary ion mass spectrometry and multivariate statistical analysis to detect and image octabenzyl-polyhedral oligomeric silsesquioxane in polycarbonate

    NASA Astrophysics Data System (ADS)

    Smentkowski, V. S.; Duong, H. M.; Tamaki, R.; Keenan, M. R.; Ohlhausen, J. A. Tony; Kotula, P. G.

    2006-11-01

    Silsesquioxane, with an empirical formula of RSiO3/2, has the potential to combine the mechanical properties of plastics with the oxidative stability of ceramics in one material [D.W. Scott, J. Am. Chem. Soc. 68 (1946) 356; K.J. Shea, D.A. Loy, Acc. Chem. Res. 34 (2001) 707; K.-M. Kim, D.-K. Keum, Y. Chujo, Macromolecules 36 (2003) 867; M.J. Abad, L. Barral, D.P. Fasce, R.J.J. William, Macromolecules 36 (2003) 3128]. The high sensitivity, surface specificity, and ability to detect and image high mass additives make time-of-flight secondary ion mass spectrometry (ToF-SIMS) a powerful surface analytical instrument for the characterization of polymer composite surfaces in an analytical laboratory [J.C. Vickerman, D. Briggs (Eds.), ToF-SIMS Surface Analysis by Mass Spectrometry, Surface Spectra/IMPublications, UK, 2001; X. Vanden Eynde, P. Bertand, Surf. Interface Anal. 27 (1999) 157; P.M. Thompson, Anal. Chem. 63 (1991) 2447; S.J. Simko, S.R. Bryan, D.P. Griffis, R.W. Murray, R.W. Linton, Anal. Chem. 57 (1985) 1198; S. Affrossman, S.A. O'Neill, M. Stamm, Macromolecules 31 (1998) 6280]. In this paper, we compare ToF-SIMS spectra of control samples with spectra generated from polymer nano-composites based on octabenzyl-polyhedral oligomeric silsesquioxane (BnPOSS) as well as spectra (and images) generated from multivariate statistical analysis (MVSA) of the entire spectral image. We will demonstrate that ToF-SIMS is able to detect and image low concentrations of BnPOSS in polycarbonate. We emphasize the use of MVSA tools for converting the massive amount of data contained in a ToF-SIMS spectral image into a smaller number of useful chemical components (spectra and images) that fully describe the ToF-SIMS measurement.

  3. The LSST Metrics Analysis Framework (MAF)

    NASA Astrophysics Data System (ADS)

    Jones, R. Lynne; Yoachim, Peter; Chandrasekharan, Srinivasan; Connolly, Andrew J.; Cook, Kem H.; Ivezic, Zeljko; Krughoff, K. Simon; Petry, Catherine E.; Ridgway, Stephen T.

    2015-01-01

    Studying potential observing strategies or cadences for the Large Synoptic Survey Telescope (LSST) is a complicated but important problem. To address this, LSST has created an Operations Simulator (OpSim) to create simulated surveys, including realistic weather and sky conditions. Analyzing the results of these simulated surveys for the wide variety of science cases to be considered for LSST is, however, difficult. We have created a Metric Analysis Framework (MAF), an open-source python framework, to be a user-friendly, customizable and easily extensible tool to help analyze the outputs of the OpSim.MAF reads the pointing history of the LSST generated by the OpSim, then enables the subdivision of these pointings based on position on the sky (RA/Dec, etc.) or the characteristics of the observations (e.g. airmass or sky brightness) and a calculation of how well these observations meet a specified science objective (or metric). An example simple metric could be the mean single visit limiting magnitude for each position in the sky; a more complex metric might be the expected astrometric precision. The output of these metrics can be generated for a full survey, for specified time intervals, or for regions of the sky, and can be easily visualized using a web interface.An important goal for MAF is to facilitate analysis of the OpSim outputs for a wide variety of science cases. A user can often write a new metric to evaluate OpSim for new science goals in less than a day once they are familiar with the framework. Some of these new metrics are illustrated in the accompanying poster, "Analyzing Simulated LSST Survey Performance With MAF".While MAF has been developed primarily for application to OpSim outputs, it can be applied to any dataset. The most obvious examples are examining pointing histories of other survey projects or telescopes, such as CFHT.

  4. Visualizing Microbial Biogeochemistry: NanoSIMS and Stable Isotope Probing (Invited)

    NASA Astrophysics Data System (ADS)

    Pett-Ridge, J.; Weber, P. K.

    2009-12-01

    Linking phylogenetic information to function in microbial communities is a key challenge for microbial ecology. Isotope-labeling experiments provide a useful means to investigate the ecophysiology of microbial populations and cells in the environment and allow measurement of nutrient transfers between cell types, symbionts and consortia. The combination of Nano-Secondary Ion Mass Spectrometry (NanoSIMS) analysis, in situ labeling and high resolution microscopy allows isotopic analysis to be linked to phylogeny and morphology and holds great promise for fine-scale studies of microbial systems. In NanoSIMS analysis, samples are sputtered with an energetic primary beam (Cs+, O-) liberating secondary ions that are separated by the mass spectrometer and detected in a suite of electron multipliers. Five isotopic species may be analyzed concurrently with spatial resolution as fine as 50nm. A high sensitivity isotope ratio ‘map’ can then be generated for the analyzed area. NanoSIMS images of 13C, 15N and Mo (a nitrogenase co-factor) localization in diazotrophic cyanobacteria show how cells differentially allocate resources within filaments and allow calculation of nutrient uptake rates on a cell by cell basis. Images of AM fungal hyphae-root and cyanobacteria-rhizobia associations indicate the mobilization and sharing (stealing?) of newly fixed C and N. In a related technique, “El-FISH”, stable isotope labeled biomass is probed with oligonucleotide-elemental labels and then imaged by NanoSIMS. In microbial consortia and cyanobacterial mats, this technique helps link microbial structure and function simultaneously even in systems with unknown and uncultivated microbes. Finally, the combination of re-engineered universal 16S oligonucleotide microarrays with NanoSIMS analyses may allow microbial identity to be linked to functional roles in complex systems such as mats and cellulose degrading hindgut communities. These newly developed methods provide correlated oligonucleotide, functional enzyme and metabolic image data and should help unravel the metabolic processes of complex microbial communities in soils, biofilms and aquatic systems.

  5. An unsupervised MVA method to compare specific regions in human breast tumor tissue samples using ToF-SIMS.

    PubMed

    Bluestein, Blake M; Morrish, Fionnuala; Graham, Daniel J; Guenthoer, Jamie; Hockenbery, David; Porter, Peggy L; Gamble, Lara J

    2016-03-21

    Imaging time-of-flight secondary ion mass spectrometry (ToF-SIMS) and principal component analysis (PCA) were used to investigate two sets of pre- and post-chemotherapy human breast tumor tissue sections to characterize lipids associated with tumor metabolic flexibility and response to treatment. The micron spatial resolution imaging capability of ToF-SIMS provides a powerful approach to attain spatially-resolved molecular and cellular data from cancerous tissues not available with conventional imaging techniques. Three ca. 1 mm(2) areas per tissue section were analyzed by stitching together 200 μm × 200 μm raster area scans. A method to isolate and analyze specific tissue regions of interest by utilizing PCA of ToF-SIMS images is presented, which allowed separation of cellularized areas from stromal areas. These PCA-generated regions of interest were then used as masks to reconstruct representative spectra from specifically stromal or cellular regions. The advantage of this unsupervised selection method is a reduction in scatter in the spectral PCA results when compared to analyzing all tissue areas or analyzing areas highlighted by a pathologist. Utilizing this method, stromal and cellular regions of breast tissue biopsies taken pre- versus post-chemotherapy demonstrate chemical separation using negatively-charged ion species. In this sample set, the cellular regions were predominantly all cancer cells. Fatty acids (i.e. palmitic, oleic, and stearic), monoacylglycerols, diacylglycerols and vitamin E profiles were distinctively different between the pre- and post-therapy tissues. These results validate a new unsupervised method to isolate and interpret biochemically distinct regions in cancer tissues using imaging ToF-SIMS data. In addition, the method developed here can provide a framework to compare a variety of tissue samples using imaging ToF-SIMS, especially where there is section-to-section variability that makes it difficult to use a serial hematoxylin and eosin (H&E) stained section to direct the SIMS analysis.

  6. Imaging of single liver tumor cells intoxicated by heavy metals using ToF-SIMS

    NASA Astrophysics Data System (ADS)

    Mai, Fu-Der; Chen, Bo-Jung; Wu, Li-Chen; Li, Feng-Yin; Chen, Wen-Kang

    2006-07-01

    Human liver tumor cells intoxicated with five different Cd, Cu, Cr, Hg and Zn metals were analyzed using imaging time-of-flight secondary ion mass spectrometry (ToF-SIMS) to visualize the metal distributions in a single cell basis. A protocol was developed by combining rapid freezing, freeze-fracture and imprinting for transferring the intoxicated cells to a silicon wafer. As shown in the ToF-SIMS images, the cellular morphology was preserved indicating that this protocol can be used to prepare a representative cell for ToF-SIMS imaging analysis. Among the five metal ions investigated in this study, only Cr and Cu ions show preferential diffusion into the cell after simulated intoxication while the signals of the other three ions are either too low to be detected or unable to be distinguished from background intensity.

  7. Operationalizing System Importance Measures for Assessing System of System Resilience

    NASA Astrophysics Data System (ADS)

    Chandrahasa, Rakshit

    In recent times, there has been a shift in focus from component level to system level analysis and an increasing effort to understand and design resilience into the system. Several efforts have been carried out in creating metrics to analyse resilience. Understanding and implementing system resilience in complex System of Systems will help us in building safer and resilient systems. System Importance Measures (SIMs) was formulated to analyse System of System resilience and help in designing a resilient SoS. Here, we operationalize these System Importance Measures for designing a resilient SoS. We first look at the existing methodology to improve the visual representation of system resilience and its usability. We demonstrate this using our first case study with a Naval warfare SoS. We incorporate probability into the SIM formulation. We expand the existing SIMs to quantify the effects of disruptions and mitigation likelihoods. We built a second case study based on Air transportation networks and demonstrated our expanded metrics in both the case studies. SIM based analysis of SoS resilience provides us with two different analysis of resilience, with and without probability. Having an outlook on how the resilience changes with a probability of disruptions can aid the designer making informed choices on design changes and help in creating a resilient SoS.

  8. The Politics of City Planning Simulations.

    ERIC Educational Resources Information Center

    Kolson, Kenneth

    This research paper presents an analysis of the computer simulation, SimCity, used for an urban city planning class. The data were gathered by actual use of the simulation and an electronic mail network was employed to secure impressions from users of the simulation. SimCity (developed by Maxis) provides the player with rules of human factors,…

  9. A study of dynamic SIMS analysis of low-k dielectric materials

    NASA Astrophysics Data System (ADS)

    Mowat, Ian A.; Lin, Xue-Feng; Fister, Thomas; Kendall, Marius; Chao, Gordon; Yang, Ming Hong

    2006-07-01

    Dynamic SIMS is an established tool for the characterization of dielectric layers in semiconductors, both for contaminant levels and for composition. As the silicon-based semiconductor industry moves towards the use of copper rather than aluminum, there is also a need to use lower k-dielectric materials to reduce RC delays and to reduce cross-talk between closely spaced metal lines. New dielectric materials pose serious challenges for implementation into semiconductor processes and also for the analytical scientist doing measurements on them. The move from inorganic materials such as SiO 2 to organic or carbon-rich low-k materials is a large change for the SIMS analyst. Low-k dielectric films from different sources can be very different materials with different analytical issues. A SIMS challenge for these materials is dealing with their insulating nature and their also fragility, particularly for porous films. These materials can be extremely sensitive to electron beam damage during charge neutralization, leading to difficulties in determining depth scales and introducing unknown errors to secondary ion counts and their subsequent conversion to concentrations. This paper presents details regarding an investigation of the effects of electron beam exposure on a low-k material. These effects and their potential impact on SIMS data will be investigated using FT-IR, TOF-SIMS, AFM and stylus profilometry.

  10. Characterization of Natural Dyes and Traditional Korean Silk Fabric by Surface Analytical Techniques.

    PubMed

    Lee, Jihye; Kang, Min Hwa; Lee, Kang-Bong; Lee, Yeonhee

    2013-05-15

    Time-of-flight secondary ion mass spectrometry (TOF-SIMS) and X-ray photoelectron spectroscopy (XPS) are well established surface techniques that provide both elemental and organic information from several monolayers of a sample surface, while also allowing depth profiling or image mapping to be carried out. The static TOF-SIMS with improved performances has expanded the application of TOF-SIMS to the study of a variety of organic, polymeric and biological materials. In this work, TOF-SIMS, XPS and Fourier Transform Infrared (FTIR) measurements were used to characterize commercial natural dyes and traditional silk fabric dyed with plant extracts dyes avoiding the time-consuming and destructive extraction procedures necessary for the spectrophotometric and chromatographic methods previously used. Silk textiles dyed with plant extracts were then analyzed for chemical and functional group identification of their dye components and mordants. TOF-SIMS spectra for the dyed silk fabric showed element ions from metallic mordants, specific fragment ions and molecular ions from plant-extracted dyes. The results of TOF-SIMS, XPS and FTIR are very useful as a reference database for comparison with data about traditional Korean silk fabric and to provide an understanding of traditional dyeing materials. Therefore, this study shows that surface techniques are useful for micro-destructive analysis of plant-extracted dyes and Korean dyed silk fabric.

  11. Evaluation of oriented lysozyme immobilized with monoclonal antibody

    NASA Astrophysics Data System (ADS)

    Aoyagi, Satoka; Okada, Keigo; Shigyo, Ayako; Man, Naoki; Karen, Akiya

    2008-12-01

    The orientation of a lysozyme immobilized with a monoclonal antibody was evaluated based on determination of the uppermost surface structure using time-of-flight secondary ion mass spectrometry (TOF-SIMS). Specific peaks of the oriented lysozyme immobilized with monoclonal anti-lysozyme antibody were obtained in comparison with reference samples, non-oriented immobilized lysozyme and immobilized anti-lysozyme antibody. All samples were freeze-dried before TOF-SIMS measurement, and then each sample was measured using TOF-SIMS with a bismuth cluster ion source. TOF-SIMS spectra were analyzed to select peaks specific to the oriented immobilized lysozyme as well as to identify their chemical formula and ensemble of amino acids. The possible chemical formulae of the lysozyme fragments were then investigated with an element matching program and a residue matching program. The results from TOF-SIMS spectra analysis were compared to the amino acid sequence of the lysozyme and its three-dimensional structure registered in the protein data bank. Finally, the fragment-ion-generating regions of the oriented immobilized lysozyme were determined based on the suggested residues and the three-dimensional structure.

  12. BioNetSim: a Petri net-based modeling tool for simulations of biochemical processes.

    PubMed

    Gao, Junhui; Li, Li; Wu, Xiaolin; Wei, Dong-Qing

    2012-03-01

    BioNetSim, a Petri net-based software for modeling and simulating biochemistry processes, is developed, whose design and implement are presented in this paper, including logic construction, real-time access to KEGG (Kyoto Encyclopedia of Genes and Genomes), and BioModel database. Furthermore, glycolysis is simulated as an example of its application. BioNetSim is a helpful tool for researchers to download data, model biological network, and simulate complicated biochemistry processes. Gene regulatory networks, metabolic pathways, signaling pathways, and kinetics of cell interaction are all available in BioNetSim, which makes modeling more efficient and effective. Similar to other Petri net-based softwares, BioNetSim does well in graphic application and mathematic construction. Moreover, it shows several powerful predominances. (1) It creates models in database. (2) It realizes the real-time access to KEGG and BioModel and transfers data to Petri net. (3) It provides qualitative analysis, such as computation of constants. (4) It generates graphs for tracing the concentration of every molecule during the simulation processes.

  13. ChromBiSim: Interactive chromatin biclustering using a simple approach.

    PubMed

    Noureen, Nighat; Zohaib, Hafiz Muhammad; Qadir, Muhammad Abdul; Fazal, Sahar

    2017-10-01

    Combinatorial patterns of histone modifications sketch the epigenomic locale. Specific positions of these modifications in the genome are marked by the presence of such signals. Various methods highlight such patterns on global scale hence missing the local patterns which are the actual hidden combinatorics. We present ChromBiSim, an interactive tool for mining subsets of modifications from epigenomic profiles. ChromBiSim efficiently extracts biclusters with their genomic locations. It is the very first user interface based and multiple cell type handling tool for decoding the interplay of subsets of histone modifications combinations along their genomic locations. It displays the results in the forms of charts and heat maps in accordance with saving them in files which could be used for post analysis. ChromBiSim tested on multiple cell types produced in total 803 combinatorial patterns. It could be used to highlight variations among diseased versus normal cell types of any species. ChromBiSim is available at (http://sourceforge.net/projects/chrombisim) in C-sharp and python languages. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Secondary ion mass spectrometry: The application in the analysis of atmospheric particulate matter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Di; Hua, Xin; Xiu, Guang-Li

    Currently, considerable attention has been paid to atmospheric particulate matter (PM) investigation due to its importance in human health and global climate change. Surface characterization of PM is important since the chemical heterogeneity between the surface and bulk may vary its impact on the environment and human being. Secondary ion mass spectrometry (SIMS) is a surface technique with high surface sensitivity, capable of high spatial chemical imaging and depth profiling. Recent research shows that SIMS holds great potential in analyzing both surface and bulk chemical information of PM. In this review, we presented the working principal of SIMS in PMmore » characterization, summarized recent applications in PM analysis from different sources, discussed its advantages and limitations, and proposed the future development of this technique with a perspective in environmental sciences.« less

  15. Use of linkage to improve the completeness of the SIM and SINASC in the Brazilian capitals

    PubMed Central

    Maia, Lívia Teixeira de Souza; de Souza, Wayner Vieira; Mendes, Antonio da Cruz Gouveia; da Silva, Aline Galdino Soares

    2017-01-01

    ABSTRACT OBJECTIVE To analyze the contribution of linkage between databases of live births and infant mortality to improve the completeness of the variables common to the Mortality Information System (SIM) and the Live Birth Information System (SINASC) in Brazilian capitals in 2012. METHODS We studied 9,001 deaths of children under one year registered in the SIM in 2012 and 1,424,691 live births present in the SINASC in 2011 and 2012. The databases were related with linkage in two steps – deterministic and probabilistic. We calculated the percentage of incompleteness of the variables common to the SIM and SINASC before and after using the technique. RESULTS We could relate 90.8% of the deaths to their respective declarations of live birth, most of them paired deterministically. We found a higher percentage of pairs in Porto Alegre, Curitiba, and Campo Grande. In the capitals of the North region, the average of pairs was 84.2%; in the South region, this result reached 97.9%. The 11 variables common to the SIM and SINASC had 11,278 incomplete fields cumulatively, and we could recover 91.4% of the data after linkage. Before linkage, five variables presented excellent completeness in the SINASC in all Brazilian capitals, but only one variable had the same status in the SIM. After applying this technique, all 11 variables of the SINASC became excellent, while this occurred in seven variables of the SIM. The city of birth was significantly associated with the death component in the quality of the information. CONCLUSIONS Despite advances in the coverage and quality of the SIM and SINASC, problems in the completeness of the variables can still be identified, especially in the SIM. In this perspective, linkage can be used to qualify important information for the analysis of infant mortality. PMID:29211201

  16. Chemical Imaging of the Cell Membrane by NanoSIMS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weber, P K; Kraft, M L; Frisz, J F

    2010-02-23

    The existence of lipid microdomains and their role in cell membrane organization are currently topics of great interest and controversy. The cell membrane is composed of a lipid bilayer with embedded proteins that can flow along the two-dimensional surface defined by the membrane. Microdomains, known as lipid rafts, are believed to play a central role in organizing this fluid system, enabling the cell membrane to carry out essential cellular processes, including protein recruitment and signal transduction. Lipid rafts are also implicated in cell invasion by pathogens, as in the case of the HIV. Therefore, understanding the role of lipid raftsmore » in cell membrane organization not only has broad scientific implications, but also has practical implications for medical therapies. One of the major limitations on lipid organization research has been the inability to directly analyze lipid composition without introducing artifacts and at the relevant length-scales of tens to hundreds of nanometers. Fluorescence microscopy is widely used due to its sensitivity and specificity to the labeled species, but only the labeled components can be observed, fluorophores can alter the behavior of the lipids they label, and the length scales relevant to imaging cell membrane domains are between that probed by fluorescence resonance energy transfer (FRET) imaging (<10 nm) and the diffraction limit of light. Topographical features can be imaged on this length scale by atomic force microscopy (AFM), but the chemical composition of the observed structures cannot be determined. Immuno-labeling can be used to study the distribution of membrane proteins at high resolution, but not lipid composition. We are using imaging mass spectrometry by secondary ion mass spectrometry (SIMS) in concert with other high resolution imaging methods to overcome these limitations. The experimental approach of this project is to combine molecule-specific stable isotope labeling with high-resolution SIMS using a Cameca NanoSIMS 50 to probe membrane organization and test microdomain hypotheses. The NanoSIMS is an imaging secondary ion mass spectrometer with an unprecedented combination of spatial resolution, sensitivity and mass specificity. It has 50 nm lateral resolution and is capable of detecting 1 in 20 nitrogen atoms while excluding near-neighbor isobaric interferences. The tightly focused cesium ion beam is rastered across the sample to produce simultaneous, quantitative digital images of up to five different masses. By labeling each specific components of a membrane with a unique rare stable isotope or element and mapping the location of the labels with the NanoSIMS, the location of the each labeled component can be determined and quantified. This new approach to membrane composition analysis allows molecular interactions of biological membranes to be probed at length-scales relevant to lipid rafts (10s to 100s of nm) that were not previously possible. Results from our most recent experiments analyzing whole cells will be presented.« less

  17. Objective assessment of gynecologic laparoscopic skills using the LapSimGyn virtual reality simulator.

    PubMed

    Larsen, C R; Grantcharov, T; Aggarwal, R; Tully, A; Sørensen, J L; Dalsgaard, T; Ottesen, B

    2006-09-01

    Safe realistic training and unbiased quantitative assessment of technical skills are required for laparoscopy. Virtual reality (VR) simulators may be useful tools for training and assessing basic and advanced surgical skills and procedures. This study aimed to investigate the construct validity of the LapSimGyn VR simulator, and to determine the learning curves of gynecologists with different levels of experience. For this study, 32 gynecologic trainees and consultants (juniors or seniors) were allocated into three groups: novices (0 advanced laparoscopic procedures), intermediate level (>20 and <60 procedures), and experts (>100 procedures). All performed 10 sets of simulations consisting of three basic skill tasks and an ectopic pregnancy program. The simulations were carried out on 3 days within a maximum period of 2 weeks. Assessment of skills was based on time, economy of movement, and error parameters measured by the simulator. The data showed that expert gynecologists performed significantly and consistently better than intermediate and novice gynecologists. The learning curves differed significantly between the groups, showing that experts start at a higher level and more rapidly reach the plateau of their learning curve than do intermediate and novice groups of surgeons. The LapSimGyn VR simulator package demonstrates construct validity on both the basic skills module and the procedural gynecologic module for ectopic pregnancy. Learning curves can be obtained, but to reach the maximum performance for the more complex tasks, 10 repetitions do not seem sufficient at the given task level and settings. LapSimGyn also seems to be flexible and widely accepted by the users.

  18. Randomized, double-blind, placebo-controlled clinical trial of loperamide plus simethicone versus loperamide alone and simethicone alone in the treatment of acute diarrhea with gas-related abdominal discomfort.

    PubMed

    Hanauer, Stephen B; DuPont, Herbert L; Cooper, Kimberly M; Laudadio, Charles

    2007-05-01

    To compare efficacy and tolerability of a loperamide/simethicone (LOP/SIM) combination product with that of loperamide (LOP) alone, simethicone (SIM) alone, and placebo (PBO) for acute nonspecific diarrhea with gas-related abdominal discomfort. In this multicenter, double-blind, 48-h study, patients were randomly assigned to receive two tablets, each containing either LOP/SIM 2 mg/125 mg (n = 121), LOP 2 mg (n = 120), SIM 125 mg (n = 123), or PBO (n = 121), followed by one tablet after each unformed stool, up to four tablets in any 24-h period. The primary outcome measures were time to last unformed stool and time to complete relief of gas-related abdominal discomfort. For time to last unformed stool, an unformed stool after a 24-h period of formed stools or no stools was considered a continuance of the original episode (stricter definition) or a new episode (alternate definition). A total of 483 patients were included in the intent-to-treat analysis. The median time to last unformed stool for LOP/SIM (7.6 h) was significantly shorter than that of LOP (11.5 h), SIM (26.0 h), and PBO (29.4 h) (p < or = 0.0232 in comparison with survival curves) using the alternate definition; it was numerically but not significantly shorter than that of LOP (p = 0.0709) and significantly shorter than that of SIM and PBO (p = 0.0001) using the stricter definition. LOP/SIM-treated patients had a shorter time to complete relief of gas-related abdominal discomfort than patients who received either ingredient alone or placebo (all p = 0.0001). Few patients reported adverse events in the four treatment groups, none of which were serious in nature. Potential study limitations include the ability to generalize study results to the population at large, variability in total dose consumed, and subjectivity of patient diary data. LOP/SIM was well-tolerated and more efficacious than LOP alone, SIM alone, or placebo for acute nonspecific diarrhea and gas-related abdominal discomfort.

  19. Quantitative analysis of the 26 allergens for cosmetic labeling in fragrance raw materials and perfume oils.

    PubMed

    Leijs, Hans; Broekhans, Joost; van Pelt, Leon; Mussinan, Cynthia

    2005-07-13

    The adoption of the 7th amendment of the European Cosmetic Directive 76/768/EEC requires any cosmetic product containing any of 26 raw materials identified by the Scientific Committee on Cosmetic Products and Non-Food Products intended for Consumers as likely to cause a contact allergy when present above certain trigger levels to be declared on the package label. Of these 26, 24 are volatile and can be analyzed by GC. This paper describes a method for the quantitative analysis of these volatile raw materials in perfume ingredients as well as complex perfume compositions. The method uses sequential dual-column GC-MS analysis. The full-scan data acquired minimize the false-positive and false-negative identifications that can be observed with alternate methods based on data acquired in the SIM mode. For each sample, allergen levels are determined on both columns sequentially, leading to two numerical results for each allergen. Quantification limits for each allergen in a perfume mixture based on the analysis of a standard are <4 mg/kg. This is well below the level that would trigger label declaration on the consumer good. Calibration curves for all allergens are linear (r > 0.999) and stable for multiple days. Studies on perfumes spiked with multiple allergens at 30, 50, and 70 mg/kg show recoveries close to nominal values.

  20. TOF-SIMS investigation of metallic material surface after culturing cells

    NASA Astrophysics Data System (ADS)

    Aoyagi, Satoka; Hiromoto, Sachiko; Hanawa, Takao; Kudo, Masahiro

    2004-06-01

    Biomolecules such as extracellular matrix and adhesive proteins generated by adhered cells on metallic specimens were characterized by means of time-of-flight secondary ion mass spectrometry (TOF-SIMS) in order to clarify the interaction between cells and metal surfaces. Since composition and structure of the extracellular matrix depends on conditions of cells, characterization of the interaction between cells and metallic specimens is important in order to evaluate the biocompatibility and the degradation behavior of metallic biomaterials and artificial organs. Moreover, the obtained data can contribute to the development of new metallic biomaterials. TOF-SIMS spectra were analyzed by means of mutual information described by information theory and principal components analysis (PCA). The results show that cells have great influence on adsorption of biomolecules on metallic materials because they change surface conditions of the materials. Thus TOF-SIMS is a useful technique to investigate the interaction between metallic biomaterials and cells.

  1. Kaiser Permanente-Sandia National Health Care Model: Phase 1 prototype final report. Part 2 -- Domain analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edwards, D.; Yoshimura, A.; Butler, D.

    This report describes the results of a Cooperative Research and Development Agreement between Sandia National Laboratories and Kaiser Permanente Southern California to develop a prototype computer model of Kaiser Permanente`s health care delivery system. As a discrete event simulation, SimHCO models for each of 100,000 patients the progression of disease, individual resource usage, and patient choices in a competitive environment. SimHCO is implemented in the object-oriented programming language C{sup 2}, stressing reusable knowledge and reusable software components. The versioned implementation of SimHCO showed that the object-oriented framework allows the program to grow in complexity in an incremental way. Furthermore, timingmore » calculations showed that SimHCO runs in a reasonable time on typical workstations, and that a second phase model will scale proportionally and run within the system constraints of contemporary computer technology.« less

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bernard, Laetitia, E-mail: laetitia.bernard@empa.ch; Leemann, Andreas

    In this study, the potential of time-of-flight secondary ion mass spectrometry (ToF-SIMS) for the application in cement-based materials is assessed in combination and comparison with scanning electron microscopy (SEM) and energy dispersive X-ray (EDX). Mortar, concrete and samples from model systems providing products formed by the alkali–silica reaction (ASR) were studied. ToF-SIMS provides qualitative data on alkalis in cases where EDX reaches its limits in regard to detectable concentration, lateral resolution and atomic number of the elements. Due to its high in-depth resolution of a few atomic monolayers, thin layers of reaction products can be detected on the surfaces andmore » chemically analyzed with ToF-SIMS. Additionally, it delivers information on the molecular conformation within the ASR product, its hydrogen content and its isotope ratios, information not provided by EDX. Provided the samples are carefully prepared, ToF-SIMS opens up new possibilities in the analysis of cement-based materials.« less

  3. Forensic practice in the field of protection of cultural heritage

    NASA Astrophysics Data System (ADS)

    Kotrlý, Marek; Turková, Ivana

    2012-06-01

    Microscopic methods play a key role in issues covering analyses of objects of art that are used on the one hand as screening ones, on the other hand they can lead to obtaining data relevant for completion of expertise. Analyses of artworks, gemmological objects and other highly valuable commodities usually do not rank among routine ones, but every analysis is specific, be it e.g. material investigation of artworks, historical textile materials and other antiques (coins, etc.), identification of fragments (from transporters, storage places, etc.), period statues, sculptures compared to originals, analyses of gems and jewellery, etc. A number of analytical techniques may be employed: optical microscopy in transmitted and reflected light, polarization and fluorescence in visible, UV and IR radiation; image analysis, quantitative microspectrophotometry; SEM/EDS/WDS; FTIR and Raman spectroscopy; XRF and microXRF, including mobile one; XRD and microXRD; x-ray backlight or LA-ICP-MS, SIMS, PIXE; further methods of organic analysis are also utilised - GS-MS, MALDI-TOF, etc.

  4. Analysis of Phenolic Antioxidants in Navy Mobility Fuels by Gas Chromatography-Mass Spectrometry

    DTIC Science & Technology

    2013-06-19

    8.0 LITERATURE CITED .........................................................................................14 APPENDIX A: Calibration Curves for...chromatogram from an F-76 diesel fuel containing 24 ppm of the AO-37 additive package, analyzed using single column GC-MS-SIM method...sulfur diesel fuel containing 6.25 ppm of the AO-37 additive package, analyzed using dual column Deans switch GC-MS-SIM method

  5. Methods for visualising active microbial benzene degraders in in situ microcosms.

    PubMed

    Schurig, Christian; Mueller, Carsten W; Höschen, Carmen; Prager, Andrea; Kothe, Erika; Beck, Henrike; Miltner, Anja; Kästner, Matthias

    2015-01-01

    Natural attenuation maybe a cost-efficient option for bioremediation of contaminated sites but requires knowledge about the activity of degrading microbes under in situ conditions. In order to link microbial activity to the spatial distribution of contaminant degraders, we combined the recently improved in situ microcosm approach, so-called 'direct-push bacterial trap' (DP-BACTRAP), with nano-scale secondary ion mass spectrometry (NanoSIMS) analysis on samples from contaminated constructed wetlands. This approach is based on initially sterile microcosms amended with (13)C-labelled benzene as a source of carbon and energy for microorganisms. The microcosms were introduced directly in the constructed wetland, where they were colonised by indigenous microorganisms from the sediment. After incubation in the field, the samples were analysed by NanoSIMS, scanning electron microscopy (SEM) and fluorescence microscopy in order to visualise (13)C-labelled microbial biomass on undisturbed samples from the microcosms. With the approach developed, we successfully visualised benzene-degrading microbes on solid materials with high surface area by means of NanoSIMS. Moreover, we could demonstrate the feasibility of NanoSIMS analysis of unembedded porous media with a highly complex topography, which was frequently reasoned to not lead to sufficient results.

  6. Improving the Molecular Ion Signal Intensity for In Situ Liquid SIMS Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Yufan; Yao, Juan; Ding, Yuanzhao

    In situ liquid secondary ion mass spectrometry (SIMS) enabled by system for analysis at the liquid vacuum interface (SALVI) has proven to be a promising new tool to provide molecular information at solid–liquid and liquid–vacuum interfaces. However, the initial data showed that useful signals in positive ion spectra are too weak to be meaningful in most cases. In addition, it is difficult to obtain strong negative molecular ion signals when m/z>200. These two drawbacks have been the biggest obstacle towards practical use of this new analytical approach. In this study, we report that strong and reliable positive and negative molecularmore » signals are achievable after optimizing the SIMS experimental conditions. Four model systems, including a 1,8-diazabicycloundec-7-ene (DBU)-base switchable ionic liquid, a live Shewanella oneidensis biofilm, a hydrated mammalian epithelia cell, and an electrolyte popularly used in Li ion batteries were studied. A signal enhancement of about two orders of magnitude was obtained in comparison with non-optimized conditions. Therefore, molecular ion signal intensity has become very acceptable to use for in situ liquid SIMS to study solid–liquid and liquid–vacuum interfaces.« less

  7. Improving the Molecular Ion Signal Intensity for In Situ Liquid SIMS Analysis.

    PubMed

    Zhou, Yufan; Yao, Juan; Ding, Yuanzhao; Yu, Jiachao; Hua, Xin; Evans, James E; Yu, Xiaofei; Lao, David B; Heldebrant, David J; Nune, Satish K; Cao, Bin; Bowden, Mark E; Yu, Xiao-Ying; Wang, Xue-Lin; Zhu, Zihua

    2016-12-01

    In situ liquid secondary ion mass spectrometry (SIMS) enabled by system for analysis at the liquid vacuum interface (SALVI) has proven to be a promising new tool to provide molecular information at solid-liquid and liquid-vacuum interfaces. However, the initial data showed that useful signals in positive ion spectra are too weak to be meaningful in most cases. In addition, it is difficult to obtain strong negative molecular ion signals when m/z>200. These two drawbacks have been the biggest obstacle towards practical use of this new analytical approach. In this study, we report that strong and reliable positive and negative molecular signals are achievable after optimizing the SIMS experimental conditions. Four model systems, including a 1,8-diazabicycloundec-7-ene (DBU)-base switchable ionic liquid, a live Shewanella oneidensis biofilm, a hydrated mammalian epithelia cell, and an electrolyte popularly used in Li ion batteries were studied. A signal enhancement of about two orders of magnitude was obtained in comparison with non-optimized conditions. Therefore, molecular ion signal intensity has become very acceptable for use of in situ liquid SIMS to study solid-liquid and liquid-vacuum interfaces. Graphical Abstract ᅟ.

  8. Higher Signal-to-Noise Measurements of Alpha-element Abundances in the M31 System

    NASA Astrophysics Data System (ADS)

    Escala, Ivanna; Kirby, Evan N.

    2018-06-01

    The stellar halo and tidal streams of M31 provide an essential counterpoint to the same structures around the Milky Way (MW). While measurements of [Fe/H] and [$\\alpha$/Fe] have been made in the MW, little is known about the detailed chemical abundances of the M31 system. To make progress with existing telescopes, we expand upon the technique first presented by Kirby et al., applying spectral synthesis to medium-resolution spectroscopy at lower spectral resolution (R $\\sim$ 1800) across an optical range (4100~\\AA \\ $<$ $\\lambda$ $<$ 9100~\\AA) that extends down the blue. We have obtained deep spectra of red giants in the tidal streams, smooth halo, and disk of M31 using the DEIMOS 600ZD grating, resulting in higher signal-to-noise per spectral resolution element (S/N $\\sim$ 30 \\AA$^{-1}$). By applying our technique to red giant stars in MW globular clusters with higher-resolution ($R$ $\\sim$ 6000) spectra in the blue (4100 - 6300 \\AA), we demonstrate that our technique reproduces previous measurements derived from the red side of the optical (6300 - 9100 \\AA). For the first time, we present measurements of [Fe/H] and [$\\alpha$/Fe] of sufficient quality and sample size to construct quantitative models of galactic chemical evolution in the M31 system.

  9. IntNetLncSim: an integrative network analysis method to infer human lncRNA functional similarity

    PubMed Central

    Hu, Yang; Yang, Haixiu; Zhou, Chen; Sun, Jie; Zhou, Meng

    2016-01-01

    Increasing evidence indicated that long non-coding RNAs (lncRNAs) were involved in various biological processes and complex diseases by communicating with mRNAs/miRNAs each other. Exploiting interactions between lncRNAs and mRNA/miRNAs to lncRNA functional similarity (LFS) is an effective method to explore function of lncRNAs and predict novel lncRNA-disease associations. In this article, we proposed an integrative framework, IntNetLncSim, to infer LFS by modeling the information flow in an integrated network that comprises both lncRNA-related transcriptional and post-transcriptional information. The performance of IntNetLncSim was evaluated by investigating the relationship of LFS with the similarity of lncRNA-related mRNA sets (LmRSets) and miRNA sets (LmiRSets). As a result, LFS by IntNetLncSim was significant positively correlated with the LmRSet (Pearson correlation γ2=0.8424) and LmiRSet (Pearson correlation γ2=0.2601). Particularly, the performance of IntNetLncSim is superior to several previous methods. In the case of applying the LFS to identify novel lncRNA-disease relationships, we achieved an area under the ROC curve (0.7300) in experimentally verified lncRNA-disease associations based on leave-one-out cross-validation. Furthermore, highly-ranked lncRNA-disease associations confirmed by literature mining demonstrated the excellent performance of IntNetLncSim. Finally, a web-accessible system was provided for querying LFS and potential lncRNA-disease relationships: http://www.bio-bigdata.com/IntNetLncSim. PMID:27323856

  10. IntNetLncSim: an integrative network analysis method to infer human lncRNA functional similarity.

    PubMed

    Cheng, Liang; Shi, Hongbo; Wang, Zhenzhen; Hu, Yang; Yang, Haixiu; Zhou, Chen; Sun, Jie; Zhou, Meng

    2016-07-26

    Increasing evidence indicated that long non-coding RNAs (lncRNAs) were involved in various biological processes and complex diseases by communicating with mRNAs/miRNAs each other. Exploiting interactions between lncRNAs and mRNA/miRNAs to lncRNA functional similarity (LFS) is an effective method to explore function of lncRNAs and predict novel lncRNA-disease associations. In this article, we proposed an integrative framework, IntNetLncSim, to infer LFS by modeling the information flow in an integrated network that comprises both lncRNA-related transcriptional and post-transcriptional information. The performance of IntNetLncSim was evaluated by investigating the relationship of LFS with the similarity of lncRNA-related mRNA sets (LmRSets) and miRNA sets (LmiRSets). As a result, LFS by IntNetLncSim was significant positively correlated with the LmRSet (Pearson correlation γ2=0.8424) and LmiRSet (Pearson correlation γ2=0.2601). Particularly, the performance of IntNetLncSim is superior to several previous methods. In the case of applying the LFS to identify novel lncRNA-disease relationships, we achieved an area under the ROC curve (0.7300) in experimentally verified lncRNA-disease associations based on leave-one-out cross-validation. Furthermore, highly-ranked lncRNA-disease associations confirmed by literature mining demonstrated the excellent performance of IntNetLncSim. Finally, a web-accessible system was provided for querying LFS and potential lncRNA-disease relationships: http://www.bio-bigdata.com/IntNetLncSim.

  11. Semiquantitative analysis of atherosclerotic plaque using optical coherence tomography and time-of-flight secondary ion mass spectrometry

    NASA Astrophysics Data System (ADS)

    Korol, Renee M.; Togonu-Bickersteth, Babajide; Yang, Victor X.; Dimov, Stamen; Vatsya, Pracha; Gordon, Maggie; Vitkin, Alex; Liu, Liying; Canham, Peter; Clarke, Sharon; Lucas, Alexandra

    2003-10-01

    Atherosclerosis is the underlying vascular pathology that initiates arterial thromboembolic occlusions (myocardial infarctions, strokes and peripheral vessel blockage). Two imaging modalities, Optical Coherence Tomography (OCT) and Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS), were investigated for detection and compositional analysis of unstable plaque associated with plaque erosion and sudden occlusion. OCT produces high resolution images whereas mass spectrometry images provide information on the spatial distribution of chemical elements. Diseased carotid arteries taken from patients with high-risk lesions were imaged with OCT and ToF-SIMS to give molecular and metabolic information, and matched with histopathology. OCT results show clear indications of vascular remodeling by the presence of fatty acid deposits, fibrous tissue and calcifications. ToF-SIMS further characterized changes based on secondary ion topography analysis where a high 23Na/39K ratio was indicative of arterial tissue degradation and the amount of 40Ca corresponded with late stage atherosclerosis. This pilot experiment has demonstrated that in vitro OCT imaging and ToF-SIMS of diseased carotid arteries have scientific merit for targeting clinically relevant morphology and metabolic changes to compare stable and unstable plaque. These optical techniques provide complimentary metabolic and molecular information on unstable plaque, specifically cell break-down with altered ion ratios of 23Na, 39K and 40Ca.

  12. Autotrophic and heterotrophic acquisition of carbon and nitrogen by a mixotrophic chrysophyte established through stable isotope analysis

    PubMed Central

    Terrado, Ramon; Pasulka, Alexis L; Lie, Alle A-Y; Orphan, Victoria J; Heidelberg, Karla B; Caron, David A

    2017-01-01

    Collectively, phagotrophic algae (mixotrophs) form a functional continuum of nutritional modes between autotrophy and heterotrophy, but the specific physiological benefits of mixotrophic nutrition differ among taxa. Ochromonas spp. are ubiquitous chrysophytes that exhibit high nutritional flexibility, although most species generally fall towards the heterotrophic end of the mixotrophy spectrum. We assessed the sources of carbon and nitrogen in Ochromonas sp. strain BG-1 growing mixotrophically via short-term stable isotope probing. An axenic culture was grown in the presence of either heat-killed bacteria enriched with 15N and 13C, or unlabeled heat-killed bacteria and labeled inorganic substrates (13C-bicarbonate and 15N-ammonium). The alga exhibited high growth rates (up to 2 divisions per day) only until heat-killed bacteria were depleted. NanoSIMS and bulk IRMS isotope analyses revealed that Ochromonas obtained 84–99% of its carbon and 88–95% of its nitrogen from consumed bacteria. The chrysophyte assimilated inorganic 13C-carbon and 15N-nitrogen when bacterial abundances were very low, but autotrophic (photosynthetic) activity was insufficient to support net population growth of the alga. Our use of nanoSIMS represents its first application towards the study of a mixotrophic alga, enabling a better understanding and quantitative assessment of carbon and nutrient acquisition by this species. PMID:28524870

  13. Role of the Cytoplasmic N-terminal Cap and Per-Arnt-Sim (PAS) Domain in Trafficking and Stabilization of Kv11.1 Channels*

    PubMed Central

    Ke, Ying; Hunter, Mark J.; Ng, Chai Ann; Perry, Matthew D.; Vandenberg, Jamie I.

    2014-01-01

    The N-terminal cytoplasmic region of the Kv11.1a potassium channel contains a Per-Arnt-Sim (PAS) domain that is essential for the unique slow deactivation gating kinetics of the channel. The PAS domain has also been implicated in the assembly and stabilization of the assembled tetrameric channel, with many clinical mutants in the PAS domain resulting in reduced stability of the domain and reduced trafficking. Here, we use quantitative Western blotting to show that the PAS domain is not required for normal channel trafficking nor for subunit-subunit interactions, and it is not necessary for stabilizing assembled channels. However, when the PAS domain is present, the N-Cap amphipathic helix must also be present for channels to traffic to the cell membrane. Serine scan mutagenesis of the N-Cap amphipathic helix identified Leu-15, Ile-18, and Ile-19 as residues critical for the stabilization of full-length proteins when the PAS domain is present. Furthermore, mutant cycle analysis experiments support recent crystallography studies, indicating that the hydrophobic face of the N-Cap amphipathic helix interacts with a surface-exposed hydrophobic patch on the core of the PAS domain to stabilize the structure of this critical gating domain. Our data demonstrate that the N-Cap amphipathic helix is critical for channel stability and trafficking. PMID:24695734

  14. XCluSim: a visual analytics tool for interactively comparing multiple clustering results of bioinformatics data

    PubMed Central

    2015-01-01

    Background Though cluster analysis has become a routine analytic task for bioinformatics research, it is still arduous for researchers to assess the quality of a clustering result. To select the best clustering method and its parameters for a dataset, researchers have to run multiple clustering algorithms and compare them. However, such a comparison task with multiple clustering results is cognitively demanding and laborious. Results In this paper, we present XCluSim, a visual analytics tool that enables users to interactively compare multiple clustering results based on the Visual Information Seeking Mantra. We build a taxonomy for categorizing existing techniques of clustering results visualization in terms of the Gestalt principles of grouping. Using the taxonomy, we choose the most appropriate interactive visualizations for presenting individual clustering results from different types of clustering algorithms. The efficacy of XCluSim is shown through case studies with a bioinformatician. Conclusions Compared to other relevant tools, XCluSim enables users to compare multiple clustering results in a more scalable manner. Moreover, XCluSim supports diverse clustering algorithms and dedicated visualizations and interactions for different types of clustering results, allowing more effective exploration of details on demand. Through case studies with a bioinformatics researcher, we received positive feedback on the functionalities of XCluSim, including its ability to help identify stably clustered items across multiple clustering results. PMID:26328893

  15. ToF-SIMS and Laser-SNMS Imaging of Heterogeneous Topographically Complex Polymer Systems.

    PubMed

    Pelster, Andreas; Körsgen, Martin; Kurosawa, Takako; Morita, Hiromi; Arlinghaus, Heinrich F

    2016-10-04

    Heterogeneous polymer coatings, such as those used in organic electronics and medical devices, are of increasing industrial importance. In order to advance the development of these types of systems, analytical techniques are required which are able to determine the elemental and molecular spatial distributions, on a nanometer scale, with very high detection efficiency and sensitivity. The goal of this study was to investigate the suitability of laser postionization secondary neutral mass spectrometry (Laser-SNMS) with a 157 nm postionization laser beam to image structured polymer mixtures and compare the results with time-of-flight secondary ion mass spectrometry (ToF-SIMS) measurements using Bi 3 + primary ions. The results showed that Laser-SNMS is better suited than ToF-SIMS for unambiguous detection and submicrometer imaging of the wide range of polymers investigated. The data also showed that Laser-SNMS has the advantage of being much more sensitive (in general higher by more than an order of magnitude and peaking at up to 3 orders of magnitude) than ToF-SIMS while also showing superior performance on topographically complex structured insulating surfaces, due to significantly reduced field effects and a higher dynamic range as compared to ToF-SIMS. It is concluded that Laser-SNMS is a powerful complementary technique to ToF-SIMS for the analysis of heterogeneous polymers and other complex structured organic mixtures, providing submicrometer resolution and high sensitivity.

  16. Characterization of Natural Dyes and Traditional Korean Silk Fabric by Surface Analytical Techniques

    PubMed Central

    Lee, Jihye; Kang, Min Hwa; Lee, Kang-Bong; Lee, Yeonhee

    2013-01-01

    Time-of-flight secondary ion mass spectrometry (TOF-SIMS) and X-ray photoelectron spectroscopy (XPS) are well established surface techniques that provide both elemental and organic information from several monolayers of a sample surface, while also allowing depth profiling or image mapping to be carried out. The static TOF-SIMS with improved performances has expanded the application of TOF-SIMS to the study of a variety of organic, polymeric and biological materials. In this work, TOF-SIMS, XPS and Fourier Transform Infrared (FTIR) measurements were used to characterize commercial natural dyes and traditional silk fabric dyed with plant extracts dyes avoiding the time-consuming and destructive extraction procedures necessary for the spectrophotometric and chromatographic methods previously used. Silk textiles dyed with plant extracts were then analyzed for chemical and functional group identification of their dye components and mordants. TOF-SIMS spectra for the dyed silk fabric showed element ions from metallic mordants, specific fragment ions and molecular ions from plant-extracted dyes. The results of TOF-SIMS, XPS and FTIR are very useful as a reference database for comparison with data about traditional Korean silk fabric and to provide an understanding of traditional dyeing materials. Therefore, this study shows that surface techniques are useful for micro-destructive analysis of plant-extracted dyes and Korean dyed silk fabric. PMID:28809257

  17. Quantitation of cocaine and cocaethylene in small volumes of rat whole blood using gas chromatography-mass spectrometry.

    PubMed

    Burdick, J D; Boni, R L; Fochtman, F W

    1997-05-01

    A simple solid phase extraction (SPE) technique combined with gas chromatography-mass spectrometry (GC/MS) operated in selected ion monitoring (SIM) mode is described for quantitation of cocaine and cocaethylene in small samples (250 microliters) of rat whole blood. Use of (N-[2H3C])-cocaine and (N-[2H3C])-cocaethylene internal standards resulted in high sensitivity and selectivity for this analytical method. Analysis was performed using a Hewlett-Packard 5890 GC equipped with a 7673A Automatic Liquid Sampler linked to a Hewlett-Packard 5972 Mass Selective Detector. Separation of analytes was accomplished on a cross-linked methyl silicone gum capillary column (Ultra 1: 12m x 0.2mm (i.d.) x 0.33 microns). Linearity was established over a wide range of concentrations (5.0-2000.0 ng ml-1) with good precision. Limits of detection (LOD) were 1.0 and 2.0 ng ml-1 for cocaine and cocaethylene, respectively. This analytical method was designed for use in pharmacokinetic experiments studying the formation of cocaethylene following ethanol pretreatment in rats administered cocaine.

  18. Polymer surface functionalities that control human embryoid body cell adhesion revealed by high throughput surface characterization of combinatorial material microarrays

    PubMed Central

    Yang, Jing; Mei, Ying; Hook, Andrew L.; Taylor, Michael; Urquhart, Andrew J.; Bogatyrev, Said R.; Langer, Robert; Anderson, Daniel G.; Davies, Martyn C.; Alexander, Morgan R.

    2010-01-01

    High throughput materials discovery using combinatorial polymer microarrays to screen for new biomaterials with new and improved function is established as a powerful strategy. Here we combine this screening approach with high throughput surface characterisation (HT-SC) to identify surface structure-function relationships. We explore how this combination can help to identify surface chemical moieties that control protein adsorption and subsequent cellular response. The adhesion of human embryoid body (hEB) cells to a large number (496) of different acrylate polymers synthesized in a microarray format is screened using a high throughput procedure. To determine the role of the polymer surface properties on hEB cell adhesion, detailed HT-SC of these acrylate polymers is carried out using time of flight secondary ion mass spectrometry (ToF SIMS), x-ray photoelectron spectroscopy (XPS), pico litre drop sessile water contact angle (WCA) measurement and atomic force microscopy (AFM). A structure-function relationship is identified between the ToF SIMS analysis of the surface chemistry after a fibronectin (Fn) pre-conditioning step and the cell adhesion to each spot using the multivariate analysis technique partial least squares (PLS) regression. Secondary ions indicative of the adsorbed Fn correlate with increased cell adhesion whereas glycol and other functionalities from the polymers are identified that reduce cell adhesion. Furthermore, a strong relationship between the ToF SIMS spectra of bare polymers and the cell adhesion to each spot is identified using PLS regression. This identifies a role for both the surface chemistry of the bare polymer and the pre-adsorbed Fn, as-represented in the ToF SIMS spectra, in controlling cellular adhesion. In contrast, no relationship is found between cell adhesion and wettability, surface roughness, elemental or functional surface composition. The correlation between ToF SIMS data of the surfaces and the cell adhesion demonstrates the ability of identifying surface moieties that control protein adsorption and subsequent cell adhesion using ToF SIMS and multivariate analysis. PMID:20832108

  19. Qualitative and quantitative analysis of PMN/T-cell interactions by InFlow and super-resolution microscopy.

    PubMed

    Balta, Emre; Stopp, Julian; Castelletti, Laura; Kirchgessner, Henning; Samstag, Yvonne; Wabnitz, Guido H

    2017-01-01

    Neutrophils or polymorphonuclear cells (PMN) eliminate bacteria via phagocytosis and/or NETosis. Apart from these conventional roles, PMN also have immune-regulatory functions. They can transdifferentiate and upregulate MHCII as well as ligands for costimulatory receptors which enables them to behave as antigen presenting cells (APC). The initial step for activating T-cells is the formation of an immune synapse between T-cells and antigen-presenting cells. However, the immune synapse that develops at the PMN/T-cell contact zone is as yet hardly investigated due to the non-availability of methods for analysis of large number of PMN interactions. In order to overcome these obstacles, we introduce here a workflow to analyse the immune synapse of primary human PMN and T-cells using multispectral imaging flow cytometry (InFlow microscopy) and super-resolution microscopy. For that purpose, we used CD3 and CD66b as the lineage markers for T-cells and PMN, respectively. Thereafter, we applied and critically discussed various "masks" for identification of T-cell PMN interactions. Using this approach, we found that a small fraction of transdifferentiated PMN (CD66b + CD86 high ) formed stable PMN/T-cell conjugates. Interestingly, while both CD3 and CD66b accumulation in the immune synapse was dependent on the maturation state of the PMN, only CD3 accumulation was greatly enhanced by the presence of superantigen. The actin cytoskeleton was weakly rearranged at the PMN side on the immune synapse upon contact with a T-cell in the presence of superantigen. A more detailed analysis using super-resolution microscopy (structured-illumination microscopy, SIM) confirmed this finding. Together, we present an InFlow microscopy based approach for the large scale analysis of PMN/T-cell interactions and - combined with SIM - a possibility for an in-depth analysis of protein translocation at the site of interactions. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Epidemilogical Simulation System, Version 2.4

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2004-01-30

    EpiSims uses a detailed simulation of disease spread to evaluate demographically and geographically targeted biological threat reduction strategies. Abstract: EpiSims simulates the spread of disease and analyzes the consequences of intervention strategies in a large urban area at the level of individuals. The simulation combines models of three dynamical systems: urban social networks, disease transmission, and within-host progression of a disease. Validated population mobility and activity generation technology provides the social network models, Disease models are based on fusion of expert opinion and available data. EpiSims provides a previously unavailable detailed representation of the course of an outbreak in urbanmore » area. A letter of August 16, 2002 from the Office of Homeland Security states: "Ability of EpiSims to provide comprehensive data on daily activity patterns of individuals makes it far superior to traditional SIR models — clearly had an impact on pre-attack smallpox vaccination policy." EpiSims leverages a unique Los Alamos National Laboratory resource — the population mobility and activity data developed by TRANSIMS (Transportation Analysis and SiMulation System) — to create epidemiological analyses at an unprecedented level of detail. We create models of microscopic (individual-level) physical and biological processes from which, through simulation, emerge the macroscopic (urban regional level) quantities that are the inputs to alternative models. For example, the contact patterns of individuals in different demographic groups determine the overall mixing rates those groups. The characteristics of a person-to-person transmission together with their contact patterns determine the reproductive numbers — how many people will be infected on average by each case. Mixing rates and reproductive numbers are the basic parameters of other epidemiological models. Because interventions — and people’s reactions to them — are ultimately applied at the individual level, EpiSims is uniquely suited to evaluate their macroscopic consequences. For example, the debate over the logistics of targeted vaccination for smallpox, and thus the magnitude of the threat it poses, can best be resolved through an individual- based approach. EpiSims is the only available analytical tool using the individual-based approach that can scale to populations of a million or more without introducing ad-hoc assumptions about the nature of the social network. Impact: The first study commissioned for the EpiSims project was to analyze the effectiveness of targeted vaccination and isolation strategies in the aftermath of a covert release of smallpox at a crowded urban location. In particular we compared casualties and resources required for targeted strategies with those in the case of large-scale quarantine and/or mass vaccination campaigns. We produced this analysis in a sixty-day effort, while prototype software was still under development and delivered it to the Office of Homeland Security in June 2002. More recently, EpiSims provided casualty estimates and cost/benefit analyses for various proposed responses to an attack with pneumonic plague during the TOPOFF-2 exercise. Capabilities: EpiSims is designed to simulate human-human transmissible disease, but it is part of a suite of tools that naturally allow it to estimate individual exposures to air-borne or water-borne spread. Combined with data on animal density and mobility, EpiSims could simulate diseases spread by non-human vectors. EpiSims incorporates reactions of individuals, and is particularly powerful if those reactions are correlated with demographics. It provides a standard for modeling scenarios that cuts across agencies.« less

  1. Analysis and imaging of biocidal agrochemicals using ToF-SIMS.

    PubMed

    Converso, Valerio; Fearn, Sarah; Ware, Ecaterina; McPhail, David S; Flemming, Anthony J; Bundy, Jacob G

    2017-09-06

    ToF-SIMS has been increasingly widely used in recent years to look at biological matrices, in particular for biomedical research, although there is still a lot of development needed to maximise the value of this technique in the life sciences. The main issue for biological matrices is the complexity of the mass spectra and therefore the difficulty to specifically and precisely detect analytes in the biological sample. Here we evaluated the use of ToF-SIMS in the agrochemical field, which remains a largely unexplored area for this technique. We profiled a large number of biocidal active ingredients (herbicides, fungicides, and insecticides); we then selected fludioxonil, a halogenated fungicide, as a model compound for more detailed study, including the effect of co-occurring biomolecules on detection limits. There was a wide range of sensitivity of the ToF-SIMS for the different active ingredient compounds, but fludioxonil was readily detected in real-world samples (wheat seeds coated with a commercial formulation). Fludioxonil did not penetrate the seed to any great depth, but was largely restricted to a layer coating the seed surface. ToF-SIMS has clear potential as a tool for not only detecting biocides in biological samples, but also mapping their distribution.

  2. 'Nano' Morphology and Element Signatures of Early Life on Earth: A New Tool for Assessing Biogenicity

    NASA Technical Reports Server (NTRS)

    Oehler, D. Z.; Mostefaoui, S.; Meibom, A.; Selo, M.; McKay, D. S.; Robert, F.

    2006-01-01

    The relatively young technology of NanoSIMS is unlocking an exciting new level of information from organic matter in ancient sediments. We are using this technique to characterize Proterozoic organic material that is clearly biogenic as a guide for interpreting controversial organic structures in either terrestrial or extraterrestrial samples. NanoSIMS is secondary ion mass spectrometry for trace element and isotope analysis at sub-micron resolution. In 2005, Robert et al. [1] combined NanoSIMS element maps with optical microscopic imagery in an effort to develop a new method for assessing biogenicity of Precambrian structures. The ability of NanoSIMS to map simultaneously the distribution of organic elements with a 50 nm spatial resolution provides new biologic markers that could help define the timing of life s development on Earth. The current study corroborates the work of Robert et al. and builds on their study by using NanoSIMS to map C, N (as CN), S, Si and O of both excellently preserved microfossils and less well preserved, non-descript organics in Proterozoic chert from the ca. 0.8 Ga Bitter Springs Formation of Australia.

  3. Hanford Soil Inventory Model (SIM-v2) Calculated Radionuclide Inventory of Direct Liquid Discharges to Soil in the Hanford Site's 200 Areas.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nichols, William E.; Zaher, U.; Agnew, S.

    The Hanford soil inventory model (SIM) provides the basic radionuclide and chemical soil inventories from historical liquid discharges to about 400 sites at the Hanford Site. Although liquid discharge inventory for chemicals is part of the SIM implementation, only radionuclide inventory is discussed here since the focus of this ECF is on providing radionuclides inputs for the composite analysis (CA) per DOE Order 435.1, Radioactive Waste Management, requirements. Furthermore, discharged inventories are only estimated for the soluble portions of the liquid discharges to waste sites/waste management areas located on the 200 Area of the Hanford Site (Central Plateau).

  4. ToF-SIMS study of differentiation of human bone-derived stromal cells: new insights into osteoporosis.

    PubMed

    Schaepe, Kaija; Werner, Janina; Glenske, Kristina; Bartges, Tessa; Henss, Anja; Rohnke, Marcus; Wenisch, Sabine; Janek, Jürgen

    2017-07-01

    Lipids have numerous important functions in the human body, as they form the cells' plasma membranes and play a key role in many disease states, presumably also in osteoporosis. Here, the fatty acid composition of the outer plasma membranes of cells differentiated into the osteogenic and adipogenic direction is studied with surface-sensitive time-of-flight secondary ion mass spectrometry (ToF-SIMS). For data evaluation, principal component analysis (PCA) is applied. Human (bone-derived) mesenchymal stromal cells (hMSCs) from an osteoporotic donor and a control donor are compared to reveal differences in the fatty acid composition of the membranes. The chemical information is correlated to staining and real-time quantitative polymerase chain reaction (rt-qPCR) results to provide insight into the gene expression of several differentiation markers on the RNA level. Adipogenic differentiation of hMSCs from a non-osteoporotic donor correlates with increased relative intensities of all fatty acids under investigation. After osteogenic differentiation of non-osteoporotic cells, the relative mass signal intensities of unsaturated fatty acids such as oleic and linoleic acids are increased. However, the osteoporotic cells show increased levels of palmitic acid in the plasma membrane after exposure to osteogenic differentiation conditions, which correlates to an immature differentiation state relative to non-osteoporotic osteogenic cells. This immature differentiation state is confirmed by increased early osteogenic differentiation factor Runx2 on RNA level and by less calcium mineralization spots seen in von Kossa staining and ToF-SIMS images. Graphical abstract Time-of-flight secondary ion mass spectrometry is applied to analyze the fatty acid composition of the outer plasma membranes of cells differentiated into the adipogenic and osteogenic direction. Cells from an osteoporotic and a control donor are compared to reveal differences due to differentiation and disease stage of the cells.

  5. Coordinated STEM/FIB/NanoSIMS Analyses of Presolar Silicates in Comet Dust and Primitive Meteorites

    NASA Technical Reports Server (NTRS)

    Keller, Lindsay; Nguyen, A.; Rahman, Z.; Messenger, S.

    2012-01-01

    Silicate grains were among the most abundant mineralogical building blocks of our Solar System. These grains were the detritus from earlier generations of stars that have been recycled in the early solar nebula. Rare sub-micrometer survivors of this processing have been identified in meteorites, micrometeorites and interplanetary dust particles (IDPs). These silicate grains are recognized as presolar in origin because of their extremely anomalous isotopic compositions that reflect nucleosynthetic processes in their stellar sources (evolved stars, novae and supernovae). We perform coordinated chemical, mineralogical and isotopic studies of these grains to determine their origins and histories. We examine the complex mineralogy and petrography of presolar silicates using imaging, diffraction and chemical data obtained from thin sections with the JSC JEOL 2500 field-emission STEM equipped with a Noran thin window energy dispersive x-ray (EDX) spectrometer and a Gatan Tridiem GIF. Quantitative element x-ray maps (spectrum images) are acquired by rastering a 4 nm incident probe whose dwell time is minimized to avoid beam damage and element diffusion during mapping. Successive image layers are acquired and combined in order to achieve approx 1% counting statistics for major elements. The IDP samples are prepared by ultramicrotomy of particles embedded in epoxy or elemental sulfur. After EDX mapping, the sections are subjected to C, N, and O isotopic imaging with the JSC NanoSIMS 50L ion microprobe. We prepare sections of some meteorite grains using the JSC FEI Quanta 3D focused ion beam (FIB) instrument. The specimen surface is protected from the FIB milling process by layers of electron beam-deposited C and Pt followed by an ion-deposited Pt layer. We also use the FIB to preferentially remove surrounding grains to reduce the background in subsequent NanoSIMS measurements. For mineralogical studies, we again employ the FIB instrument to deposit a protective cap over the grain of interest and then extract the grain and thin it to electron transparency for TEM analysis.

  6. A tutorial platform suitable for surgical simulator training (SimMentor).

    PubMed

    Røtnes, Jan Sigurd; Kaasa, Johannes; Westgaard, Geir; Eriksen, Eivind Myrold; Hvidsten, Per Oyvind; Strøm, Kyrre; Sørhus, Vidar; Halbwachs, Yvon; Haug, Einar; Grimnes, Morten; Fontenelle, Hugues; Ekeberg, Tom; Thomassen, Jan B; Elle, Ole Jakob; Fosse, Erik

    2002-01-01

    The introduction of simulators in surgical training entails the need to develop pedagogic platforms adapted to the potentials and limitations provided by the information technology. As a solution to the technical challenges in treating all possible interaction events and to obtain a suitable pedagogic approach, we have developed a pedagogic platform for surgical training, SimMentor. In SimMentor the procedure to be practiced is divided into a number of natural phases. The trainee will practice on one phase at a time, however he can select the sequence of phases arbitrarily. A phase is taught by letting the trainee alternate freely between 2 modes: 1: A 3-dimensional animated guidance designed for learning the objectives and challenges in a procedure. 2: An interactive training session through the instrument manipulator device designed for training motoric responses based on visual and tactile responses produced by the simulator. The two modes are interfaced with the same virtual reality platform, thus SimMentor allows a seamless transition between the modes. We have developed a prototype simulator for robotic assisted endoscopic CABG (Coronary Artery Bypass Grafting) procedure by first focusing on the anastomosis part of the operation. Tissue, suture and instrument models have been developed and integrated with a simulated model of a beating heart comprises the elements in the simulator engine that is used in construction a training platform for learning different methods for performing a coronary anastomosis procedure. The platform is designed for integrating the following features: 1) practical approach to handle interactivity events with flexible-objects 3D simulators, 2) methods for quantitative evaluations of performance, 3) didactic presentations, 4) effective ways of producing diversity of clinical and pathological training scenarios.

  7. Role of Prostaglandin Pathway and Alendronate-Based Carriers to Enhance Statin-induced Bone

    PubMed Central

    Lee, Yeonju; Liu, Xinming; Nawshad, Ali; Marx, David B.; Wang, Dong; Reinhardt, Richard A.

    2011-01-01

    Objective This study investigated the role of the prostaglandin (PG) pathway in locally-applied, simvastatin-induced oral bone growth. The possibility of enhancing long-term bone augmentation with an alendronate-based carrier was initiated. Methods Mandibles of 44 mature female rats were treated bilaterally with the following combinations: 2 mg simvastatin in ethanol (SIM-EtOH), EtOH, 2 mg simvastatin acid complexed with alendronate-beta-cyclodextrin conjugate (SIM/ALN-CD), ALN-CD, or ALN. Bone wash technology (injection of PBS and recollection by suction) was used to sample injection sites at baseline (day 0), and 3, 7, 14 and 21 days post-treatment. After 21-24 or 48 days, histomorphometric analysis was done. The amount of PGE2 in bone wash fluid was measured by ELISA, normalized by total protein, and compared between high and low bone growth groups (ANOVA) and correlated with subsequent bone histology at 21 days (Spearman). SIM-stimulated PGE2 synthase and EP4 receptor mRNA in murine osteoblast and fibroblast cell lines were evaluated with real-time PCR. Results Single injections of 2 mg SIM-EtOH induced significantly more new bone than control side after 21 days. PGE2/protein ratios peaked at day 7 and were correlated with the subsequent 21-day new bone width. The correlations at day 14 between PGE2 and new bone width changed to a negative relationship in the test group. SIM-stimulated osteoblasts expressed increased mRNA levels of PGE receptor EP4, while SIM activated PGE synthesis in fibroblasts. SIM/ALN-CD tended to preserve bone long-term. Conclusion Findings suggest that PGE pathway activation and higher levels of PGE2 during the first week following SIM-induced bone growth are desirable, and alendronate-beta-cyclodextrin conjugates not only act as tissue-specific carriers, but preserve new bone. PMID:21438610

  8. Biological Analysis of Simvastatin-releasing Chitosan Scaffold as a Cell-free System for Pulp-dentin Regeneration.

    PubMed

    Soares, Diana G; Anovazzi, Giovanna; Bordini, Ester Alves F; Zuta, Uxua O; Silva Leite, Maria Luísa A; Basso, Fernanda G; Hebling, Josimeri; de Souza Costa, Carlos A

    2018-06-01

    The improvement of biomaterials capable of driving the regeneration of the pulp-dentin complex mediated by resident cells is the goal of regenerative dentistry. In the present investigation, a chitosan scaffold (CHSC) that released bioactive concentrations of simvastatin (SIM) was tested, aimed at the development of a cell-free tissue engineering system. First, we performed a dose-response assay to select the bioactive dose of SIM capable of inducing an odontoblastic phenotype in dental pulp cells (DPCs); after which we evaluated the synergistic effect of this dosage with the CHSC/DPC construct. SIM at 1.0 μmol/L (CHSC-SIM1.0) and 0.5 μmol/L were incorporated into the CHSC, and cell viability, adhesion, and calcium deposition were evaluated. Finally, we assessed the biomaterials in an artificial pulp chamber/3-dimensional culture model to simulate the cell-free approach in vitro. SIM at 0.1 μmol/L was selected as the bioactive dose. This drug was capable of strongly inducing an odontoblastic phenotype on the DPC/CHSC construct. The incorporation of SIM into CHSC had no deleterious effect on cell viability and adhesion to the scaffold structure. CHSC-SIM1.0 led to significantly higher calcium-rich matrix deposition on scaffold/dentin disc assay compared with the control (CHSC). This biomaterial induced the migration of DPCs from a 3-dimensional culture to its surface as well as stimulated significantly higher expressions of alkaline phosphatase, collagen type 1 alpha 1, dentin matrix acidic phosphoprotein 1, and dentin sialophosphoprotein on 3-dimensional-cultured DPCs than on those in contact with CHSC. CHSC-SIM1.0 scaffold was capable of increasing the chemotaxis and regenerative potential of DPCs. Copyright © 2018 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  9. A comparative ToF-SIMS and GC—MS analysis of phototrophic communities collected from an alkaline silica-depositing hot spring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siljestrom, S.; Parenteau, M. N.; Jahnke, L. L.

    One of few techniques that is able to spatially resolve chemical data, including organic molecules, to morphological features in modern and ancient geological samples, is time-of-flight secondary ion mass spectrometry (ToF-SIMS). The ability to connect chemical data to morphology is key for interpreting the biogenicity of preserved remains in ancient samples. However, due to the lack of reference data for geologically relevant samples and the ease with which samples can be contaminated, ToF-SIMS data may be difficult to interpret. In this project, we aimed to build a ToF-SIMS spectral database by performing parallel ToF-SIMS and gas chromatography–mass spectrometry (GC–MS) analysesmore » of extant photosynthetic microbial communities collected from an alkaline silica-depositing hot spring in Yellowstone National Park, USA. We built the library by analyzing samples of increasing complexity: pure lipid standards commonly found in thermophilic phototrophs, solvent extracts of specific lipid fractions, total lipid extracts, pure cultures of dominant phototrophic community members, and unsilicified phototrophic streamer communities. The results showed that important lipids and pigments originating from phototrophs were detected by ToF-SIMS (e.g., wax esters, monogalactosyldiacylglycerol, digalactosyldiacylglycerol, sufloquinovosyldiaglycerol, alkanes, etc.) in the streamer lipid extracts. Many of the lipids were also detected in situ in the unsilicified streamer, and could even be spatially resolved to individual cells within the streamer community. Together with the ToF-SIMS database, this mapping ability will be used to further explore other microbial mats and their fossilized counterparts in the geological record. This is likely to expand the geochemical understanding of these types of samples.« less

  10. A comparative ToF-SIMS and GC—MS analysis of phototrophic communities collected from an alkaline silica-depositing hot spring

    DOE PAGES

    Siljestrom, S.; Parenteau, M. N.; Jahnke, L. L.; ...

    2017-04-03

    One of few techniques that is able to spatially resolve chemical data, including organic molecules, to morphological features in modern and ancient geological samples, is time-of-flight secondary ion mass spectrometry (ToF-SIMS). The ability to connect chemical data to morphology is key for interpreting the biogenicity of preserved remains in ancient samples. However, due to the lack of reference data for geologically relevant samples and the ease with which samples can be contaminated, ToF-SIMS data may be difficult to interpret. In this project, we aimed to build a ToF-SIMS spectral database by performing parallel ToF-SIMS and gas chromatography–mass spectrometry (GC–MS) analysesmore » of extant photosynthetic microbial communities collected from an alkaline silica-depositing hot spring in Yellowstone National Park, USA. We built the library by analyzing samples of increasing complexity: pure lipid standards commonly found in thermophilic phototrophs, solvent extracts of specific lipid fractions, total lipid extracts, pure cultures of dominant phototrophic community members, and unsilicified phototrophic streamer communities. The results showed that important lipids and pigments originating from phototrophs were detected by ToF-SIMS (e.g., wax esters, monogalactosyldiacylglycerol, digalactosyldiacylglycerol, sufloquinovosyldiaglycerol, alkanes, etc.) in the streamer lipid extracts. Many of the lipids were also detected in situ in the unsilicified streamer, and could even be spatially resolved to individual cells within the streamer community. Together with the ToF-SIMS database, this mapping ability will be used to further explore other microbial mats and their fossilized counterparts in the geological record. This is likely to expand the geochemical understanding of these types of samples.« less

  11. A comparative ToF-SIMS and GC–MS analysis of phototrophic communities collected from an alkaline silica-depositing hot spring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siljeström, S.; Parenteau, M. N.; Jahnke, L. L.

    One of few techniques that is able to spatially resolve chemical data, including organic molecules, to morphological features in modern and ancient geological samples, is time-of-flight secondary ion mass spectrometry (ToF-SIMS). The ability to connect chemical data to morphology is key for interpreting the biogenicity of preserved remains in ancient samples. However, due to the lack of reference data for geologically relevant samples and the ease with which samples can be contaminated, ToF-SIMS data may be difficult to interpret. In this project, we aimed to build a ToF-SIMS spectral database by performing parallel ToF-SIMS and gas chromatography–mass spectrometry (GC–MS) analysesmore » of extant photosynthetic microbial communities collected from an alkaline silica-depositing hot spring in Yellowstone National Park, USA. We built the library by analyzing samples of increasing complexity: pure lipid standards commonly found in thermophilic phototrophs, solvent extracts of specific lipid fractions, total lipid extracts, pure cultures of dominant phototrophic community members, and unsilicified phototrophic streamer communities. The results showed that important lipids and pigments originating from phototrophs were detected by ToF-SIMS (e.g., wax esters, monogalactosyldiacylglycerol, digalactosyldiacylglycerol, sufloquinovosyldiaglycerol, alkanes, etc.) in the streamer lipid extracts. Many of the lipids were also detected in situ in the unsilicified streamer, and could even be spatially resolved to individual cells within the streamer community. Together with the ToF-SIMS database, this mapping ability will be used to further explore other microbial mats and their fossilized counterparts in the geological record. This is likely to expand the geochemical understanding of these types of samples.« less

  12. Comparing surgically induced astigmatism calculated by means of simulated keratometry versus total corneal refractive power.

    PubMed

    Garzón, Nuria; Rodríguez-Vallejo, Manuel; Carmona, David; Calvo-Sanz, Jorge A; Poyales, Francisco; Palomino, Carlos; Zato-Gómez de Liaño, Miguel Á; Fernández, Joaquín

    2018-03-01

    To evaluate surgically induced astigmatism as computed by means of either simulated keratometry (K SIM ) or total corneal refractive power (TCRP) after temporal incisions. Prospective observational study including 36 right eyes undergoing cataract surgery. Astigmatism was measured preoperatively during the 3-month follow-up period using Pentacam. Surgically induced astigmatism was computed considering anterior corneal surface astigmatism at 3 mm with K SIM and considering both corneal surfaces with TCRP from 1 to 8 mm (TCRP 3 for 3 mm). The eyes under study were divided into two balanced groups: LOW with K SIM astigmatism <0.90 D and HIGH with K SIM astigmatism ≥0.90 D. Resulting surgically induced astigmatism values were compared across groups and measuring techniques by means of flattening, steepening, and torque analysis. Mean surgically induced astigmatism was higher in the HIGH group (0.31 D @ 102°) than in the LOW group (0.04 D @ 16°). The temporal incision resulted in a steepening in the HIGH group of 0.15 D @ 90°, as estimated with K SIM , versus 0.28 D @ 90° with TCRP 3 , but no significant differences were found for the steepening in the LOW group or for the torque in either group. Differences between K SIM - and TCRP 3 -based surgically induced astigmatism values were negligible in LOW group. Surgically induced astigmatism was considerably higher in the high-astigmatism group and its value was underestimated with the K SIM approach. Eyes having low astigmatism should not be included for computing the surgically induced astigmatism because steepening would be underestimated.

  13. Pediatric siMS score: A new, simple and accurate continuous metabolic syndrome score for everyday use in pediatrics.

    PubMed

    Vukovic, Rade; Milenkovic, Tatjana; Stojan, George; Vukovic, Ana; Mitrovic, Katarina; Todorovic, Sladjana; Soldatovic, Ivan

    2017-01-01

    The dichotomous nature of the current definition of metabolic syndrome (MS) in youth results in loss of information. On the other hand, the calculation of continuous MS scores using standardized residuals in linear regression (Z scores) or factor scores of principal component analysis (PCA) is highly impractical for clinical use. Recently, a novel, easily calculated continuous MS score called siMS score was developed based on the IDF MS criteria for the adult population. To develop a Pediatric siMS score (PsiMS), a modified continuous MS score for use in the obese youth, based on the original siMS score, while keeping the score as simple as possible and retaining high correlation with more complex scores. The database consisted of clinical data on 153 obese (BMI ≥95th percentile) children and adolescents. Continuous MS scores were calculated using Z scores and PCA, as well as the original siMS score. Four variants of PsiMS score were developed in accordance with IDF criteria for MS in youth and correlation of these scores with PCA and Z score derived MS continuous scores was assessed. PsiMS score calculated using formula: (2xWaist/Height) + (Glucose(mmol/l)/5.6) + (triglycerides(mmol/l)/1.7) + (Systolic BP/130)-(HDL(mmol/l)/1.02) showed the highest correlation with most of the complex continuous scores (0.792-0.901). The original siMS score also showed high correlation with continuous MS scores. PsiMS score represents a practical and accurate score for the evaluation of MS in the obese youth. The original siMS score should be used when evaluating large cohorts consisting of both adults and children.

  14. CBP PHASE I CODE INTEGRATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, F.; Brown, K.; Flach, G.

    The goal of the Cementitious Barriers Partnership (CBP) is to develop a reasonable and credible set of software tools to predict the structural, hydraulic, and chemical performance of cement barriers used in nuclear applications over extended time frames (greater than 100 years for operating facilities and greater than 1000 years for waste management). The simulation tools will be used to evaluate and predict the behavior of cementitious barriers used in near surface engineered waste disposal systems including waste forms, containment structures, entombments, and environmental remediation. These cementitious materials are exposed to dynamic environmental conditions that cause changes in material propertiesmore » via (i) aging, (ii) chloride attack, (iii) sulfate attack, (iv) carbonation, (v) oxidation, and (vi) primary constituent leaching. A set of state-of-the-art software tools has been selected as a starting point to capture these important aging and degradation phenomena. Integration of existing software developed by the CBP partner organizations was determined to be the quickest method of meeting the CBP goal of providing a computational tool that improves the prediction of the long-term behavior of cementitious materials. These partner codes were selected based on their maturity and ability to address the problems outlined above. The GoldSim Monte Carlo simulation program (GTG 2010a, GTG 2010b) was chosen as the code integration platform (Brown & Flach 2009b). GoldSim (current Version 10.5) is a Windows based graphical object-oriented computer program that provides a flexible environment for model development (Brown & Flach 2009b). The linking of GoldSim to external codes has previously been successfully demonstrated (Eary 2007, Mattie et al. 2007). GoldSim is capable of performing deterministic and probabilistic simulations and of modeling radioactive decay and constituent transport. As part of the CBP project, a general Dynamic Link Library (DLL) interface was developed to link GoldSim with external codes (Smith III et al. 2010). The DLL uses a list of code inputs provided by GoldSim to create an input file for the external application, runs the external code, and returns a list of outputs (read from files created by the external application) back to GoldSim. In this way GoldSim provides: (1) a unified user interface to the applications, (2) the capability of coupling selected codes in a synergistic manner, and (3) the capability of performing probabilistic uncertainty analysis with the codes. GoldSim is made available by the GoldSim Technology Group as a free 'Player' version that allows running but not editing GoldSim models. The player version makes the software readily available to a wider community of users that would wish to use the CBP application but do not have a license for GoldSim.« less

  15. Atom Probe Tomography Analysis of Gallium-Nitride-Based Light-Emitting Diodes

    NASA Astrophysics Data System (ADS)

    Prosa, Ty J.; Olson, David; Giddings, A. Devin; Clifton, Peter H.; Larson, David J.; Lefebvre, Williams

    2014-03-01

    Thin-film light-emitting diodes (LEDs) composed of GaN/InxGa1-xN/GaN quantum well (QW) structures are integrated into modern optoelectronic devices because of the tunable InGaN band-gap enabling emission of the full visible spectrum. Atom probe tomography (APT) offers unique capabilities for 3D device characterization including compositional mapping of nano-volumes (>106 nm3) , high detection efficiency (>50%), and good sensitivity. In this study, APT is used to understand the distribution of dopants as well as Al and In alloying agents in a GaN device. Measurements using transmission electron microscopy (TEM) and secondary ion mass spectrometry (SIMS) have also been made to improve the accuracy of the APT analysis by correlating the information content of these complimentary techniques. APT analysis reveals various QW and other optoelectronic structures including a Mg p-GaN layer, an Al-rich electron blocking layer, an In-rich multi-QW region, and an In-based super-lattice structure. The multi-QW composition shows good quantitative agreement with layer thickness and spacing extracted from a high resolution TEM image intensity analysis.

  16. A very large ( θ E ≳ 40") strong gravitational lens selected with the Sunyaev–Zel’dovich effect: PLCK G287.0+32.9 ( z = 0.38)

    DOE PAGES

    Zitrin, Adi; Seitz, Stella; Monna, Anna; ...

    2017-04-10

    Since galaxy clusters sit at the high end of the mass function, the number of galaxy clusters both massive and concentrated enough to yield particularly large Einstein radii poses useful constraints on cosmological and structure formation models. To date, less than a handful of clusters are known to have Einstein radii exceedingmore » $$\\sim 40^{\\prime\\prime} $$ (for a source at $${z}_{s}\\simeq 2$$, nominally). Here, we report an addition to that list of the Sunyaev–Zel'dovich (SZ) selected cluster, PLCK G287.0+32.9 (z = 0.38), the second-highest SZ-mass (M 500) cluster from the Planck catalog. We present the first strong-lensing analysis of the cluster, identifying 20 sets of multiply imaged galaxies and candidates in new Hubble Space Telescope ( HST) data, including a long, $$l\\sim 22^{\\prime\\prime} $$ giant arc, as well as a quadruply imaged, apparently bright (magnified to $${J}_{{\\rm{F}}110{\\rm{W}}}=25.3$$ AB), likely high-redshift dropout galaxy at $${z}_{\\mathrm{phot}}=6.90$$ [6.13–8.43] (95% C.I.). Our analysis reveals a very large critical area (1.55 arcmin2, $${z}_{s}\\simeq 2$$), corresponding to an effective Einstein radius of $${\\theta }_{{\\rm{E}}}\\sim 42^{\\prime\\prime} $$. Furthermore, the model suggests the critical area will expand to 2.58 arcmin2 ($${\\theta }_{{\\rm{E}}}\\sim 54^{\\prime\\prime} $$) for sources at $${z}_{s}\\sim 10$$. Our work adds to recent efforts to model very massive clusters toward the launch of the James Webb Space Telescope, in order to identify the most useful cosmic lenses for studying the early universe. Spectroscopic redshifts for the multiply imaged galaxies and additional HST data will be necessary for refining the lens model and verifying the nature of the $$z\\sim 7$$ dropout.« less

  17. A very large ( θ E ≳ 40") strong gravitational lens selected with the Sunyaev–Zel’dovich effect: PLCK G287.0+32.9 ( z = 0.38)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zitrin, Adi; Seitz, Stella; Monna, Anna

    Since galaxy clusters sit at the high end of the mass function, the number of galaxy clusters both massive and concentrated enough to yield particularly large Einstein radii poses useful constraints on cosmological and structure formation models. To date, less than a handful of clusters are known to have Einstein radii exceedingmore » $$\\sim 40^{\\prime\\prime} $$ (for a source at $${z}_{s}\\simeq 2$$, nominally). Here, we report an addition to that list of the Sunyaev–Zel'dovich (SZ) selected cluster, PLCK G287.0+32.9 (z = 0.38), the second-highest SZ-mass (M 500) cluster from the Planck catalog. We present the first strong-lensing analysis of the cluster, identifying 20 sets of multiply imaged galaxies and candidates in new Hubble Space Telescope ( HST) data, including a long, $$l\\sim 22^{\\prime\\prime} $$ giant arc, as well as a quadruply imaged, apparently bright (magnified to $${J}_{{\\rm{F}}110{\\rm{W}}}=25.3$$ AB), likely high-redshift dropout galaxy at $${z}_{\\mathrm{phot}}=6.90$$ [6.13–8.43] (95% C.I.). Our analysis reveals a very large critical area (1.55 arcmin2, $${z}_{s}\\simeq 2$$), corresponding to an effective Einstein radius of $${\\theta }_{{\\rm{E}}}\\sim 42^{\\prime\\prime} $$. Furthermore, the model suggests the critical area will expand to 2.58 arcmin2 ($${\\theta }_{{\\rm{E}}}\\sim 54^{\\prime\\prime} $$) for sources at $${z}_{s}\\sim 10$$. Our work adds to recent efforts to model very massive clusters toward the launch of the James Webb Space Telescope, in order to identify the most useful cosmic lenses for studying the early universe. Spectroscopic redshifts for the multiply imaged galaxies and additional HST data will be necessary for refining the lens model and verifying the nature of the $$z\\sim 7$$ dropout.« less

  18. San Francisco Deep Ocean Dredged Material Disposal Site (SF-DODS) Monitoring Program. Physical, Chemical, and Benthic Community Monitoring

    DTIC Science & Technology

    2003-08-29

    analyzed for total volatile solids, total organic carbon, oil and grease/total petroleum hydrocarbons , grain size distribution, metals, polycyclic...TBT Tri-Butyltin TOC Total Organic Carbon TPCB Total Polychlorinated Biphenyls TPH Total Petroleum Hydrocarbons USACE U.S. Army Corps of Engineers U.S...Health PQL Practical Quantitation Limit RCRA Resource Conservation and Recovery Act SIM Selected Ion Monitoring TPH Total Petroleum Hydrocarbons tr Trace

  19. ToF-SIMS and principal component analysis of lipids and amino acids from inflamed and dysplastic human colonic mucosa.

    PubMed

    Urbini, Marco; Petito, Valentina; de Notaristefani, Francesco; Scaldaferri, Franco; Gasbarrini, Antonio; Tortora, Luca

    2017-10-01

    Here, time of flight secondary ion mass spectrometry (ToF-SIMS) and multivariate analysis were combined to study the role of ulcerative colitis (UC), a type of inflammatory bowel disease (IBD), in the colon cancer progression. ToF-SIMS was used to obtain mass spectra and chemical maps from the mucosal surface of human normal (NC), inflamed (IC), and dysplastic (DC) colon tissues. Chemical mapping with a lateral resolution of ≈ 1 μm allowed to evaluate zonation of fatty acids and amino acids as well as the morphological condition of the intestinal glands. High mass resolution ToF-SIMS spectra showed chemical differences in lipid and amino acid composition as a function of pathological state. In positive ion mode, mono- (MAG), di- (DAG), and triacylglycerol (TAG) signals were detected in NC tissues, while in IC and DC tissues, the only cholesterol was present as lipid class representative. Signals from fatty acids, collected in negative ion mode, were subjected to principal component analysis (PCA). PCA showed a strict correlation between IC and DC samples, due to an increase of stearic, arachidonic, and linoleic acid. In the same way, differences in the amino acid composition were highlighted through multivariate analysis. PCA revealed that glutamic acid, leucine/isoleucine, and valine fragments are related to IC tissues. On the other hand, tyrosine, methionine, and tryptophan peaks contributed highly to the separation of DC tissues. Finally, a classification of NC, IC, and DC patients was also achieved through hierarchical cluster analysis of amino acid fragments. In this case, human colonic inflammation showed a stronger relationship with normal than dysplastic condition. Graphical Abstract ᅟ.

  20. Endosomal Interactions during Root Hair Growth

    PubMed Central

    von Wangenheim, Daniel; Rosero, Amparo; Komis, George; Šamajová, Olga; Ovečka, Miroslav; Voigt, Boris; Šamaj, Jozef

    2016-01-01

    The dynamic localization of endosomal compartments labeled with targeted fluorescent protein tags is routinely followed by time lapse fluorescence microscopy approaches and single particle tracking algorithms. In this way trajectories of individual endosomes can be mapped and linked to physiological processes as cell growth. However, other aspects of dynamic behavior including endosomal interactions are difficult to follow in this manner. Therefore, we characterized the localization and dynamic properties of early and late endosomes throughout the entire course of root hair formation by means of spinning disc time lapse imaging and post-acquisition automated multitracking and quantitative analysis. Our results show differential motile behavior of early and late endosomes and interactions of late endosomes that may be specified to particular root hair domains. Detailed data analysis revealed a particular transient interaction between late endosomes—termed herein as dancing-endosomes—which is not concluding to vesicular fusion. Endosomes preferentially located in the root hair tip interacted as dancing-endosomes and traveled short distances during this interaction. Finally, sizes of early and late endosomes were addressed by means of super-resolution structured illumination microscopy (SIM) to corroborate measurements on the spinning disc. This is a first study providing quantitative microscopic data on dynamic spatio-temporal interactions of endosomes during root hair tip growth. PMID:26858728

  1. Endosomal Interactions during Root Hair Growth.

    PubMed

    von Wangenheim, Daniel; Rosero, Amparo; Komis, George; Šamajová, Olga; Ovečka, Miroslav; Voigt, Boris; Šamaj, Jozef

    2015-01-01

    The dynamic localization of endosomal compartments labeled with targeted fluorescent protein tags is routinely followed by time lapse fluorescence microscopy approaches and single particle tracking algorithms. In this way trajectories of individual endosomes can be mapped and linked to physiological processes as cell growth. However, other aspects of dynamic behavior including endosomal interactions are difficult to follow in this manner. Therefore, we characterized the localization and dynamic properties of early and late endosomes throughout the entire course of root hair formation by means of spinning disc time lapse imaging and post-acquisition automated multitracking and quantitative analysis. Our results show differential motile behavior of early and late endosomes and interactions of late endosomes that may be specified to particular root hair domains. Detailed data analysis revealed a particular transient interaction between late endosomes-termed herein as dancing-endosomes-which is not concluding to vesicular fusion. Endosomes preferentially located in the root hair tip interacted as dancing-endosomes and traveled short distances during this interaction. Finally, sizes of early and late endosomes were addressed by means of super-resolution structured illumination microscopy (SIM) to corroborate measurements on the spinning disc. This is a first study providing quantitative microscopic data on dynamic spatio-temporal interactions of endosomes during root hair tip growth.

  2. User Guide for GoldSim Model to Calculate PA/CA Doses and Limits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, F.

    2016-10-31

    A model to calculate doses for solid waste disposal at the Savannah River Site (SRS) and corresponding disposal limits has been developed using the GoldSim commercial software. The model implements the dose calculations documented in SRNL-STI-2015-00056, Rev. 0 “Dose Calculation Methodology and Data for Solid Waste Performance Assessment (PA) and Composite Analysis (CA) at the Savannah River Site”.

  3. GUM Analysis for TIMS and SIMS Isotopic Ratios in Graphite

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heasler, Patrick G.; Gerlach, David C.; Cliff, John B.

    2007-04-01

    This report describes GUM calculations for TIMS and SIMS isotopic ratio measurements of reactor graphite samples. These isotopic ratios are used to estimate reactor burn-up, and currently consist of various ratios of U, Pu, and Boron impurities in the graphite samples. The GUM calculation is a propagation of error methodology that assigns uncertainties (in the form of standard error and confidence bound) to the final estimates.

  4. TOF-SIMS imaging of protein adsorption on dialysis membrane

    NASA Astrophysics Data System (ADS)

    Aoyagi, Satoka; Hayama, Msayo; Hasegawa, Urara; Sakai, Kiyotaka; Hoshi, Takahiro; Kudo, Masahiro

    2004-06-01

    Time-of-flight secondary ion mass spectrometry (TOF-SIMS) is capable of chemical imaging of proteins on insulated samples such as hollow-fiber dialysis membranes. Albumin loss and a lowering of diffusive permeability caused by protein adsorption on dialysis membranes should be reduced in order to enhance dialysis adequacy of the patients. Bovine serum albumin (BSA)-adsorbed hollow-fiber dialysis membranes were tested in the present study. TOF-SIMS images and spectra of both native membranes and BSA-adsorbed membranes were compared in order to identify secondary ions related to BSA and membranes. Peaks of secondary ions related to BSA and each membrane were selected by means of information theory, and they are characterized by principal component analysis (PCA). Chemical images of BSA adsorption on both native and treated membranes were obtained to find that BSA permeability and interaction between the membranes and BSA definitely depend on the properties of a membrane. TOF-SIMS imaging obtained with information theory is a powerful tool to estimate protein adsorption on the dialysis membranes.

  5. The Parallel System for Integrating Impact Models and Sectors (pSIMS)

    NASA Technical Reports Server (NTRS)

    Elliott, Joshua; Kelly, David; Chryssanthacopoulos, James; Glotter, Michael; Jhunjhnuwala, Kanika; Best, Neil; Wilde, Michael; Foster, Ian

    2014-01-01

    We present a framework for massively parallel climate impact simulations: the parallel System for Integrating Impact Models and Sectors (pSIMS). This framework comprises a) tools for ingesting and converting large amounts of data to a versatile datatype based on a common geospatial grid; b) tools for translating this datatype into custom formats for site-based models; c) a scalable parallel framework for performing large ensemble simulations, using any one of a number of different impacts models, on clusters, supercomputers, distributed grids, or clouds; d) tools and data standards for reformatting outputs to common datatypes for analysis and visualization; and e) methodologies for aggregating these datatypes to arbitrary spatial scales such as administrative and environmental demarcations. By automating many time-consuming and error-prone aspects of large-scale climate impacts studies, pSIMS accelerates computational research, encourages model intercomparison, and enhances reproducibility of simulation results. We present the pSIMS design and use example assessments to demonstrate its multi-model, multi-scale, and multi-sector versatility.

  6. Characterization of high explosive particles using cluster secondary ion mass spectrometry.

    PubMed

    Gillen, Greg; Mahoney, Christine; Wight, Scott; Lareau, Richard

    2006-01-01

    The use of secondary ion mass spectrometry (SIMS) for the detection and spatially resolved analysis of individual high explosive particles is described. A C(8) (-) carbon cluster primary ion beam was used in a commercial SIMS instrument to analyze samples of high explosives dispersed as particles on silicon substrates. In comparison with monatomic primary ion bombardment, the carbon cluster primary ion beam was found to greatly enhance characteristic secondary ion signals from the explosive compounds while causing minimal beam-induced degradation. The resistance of these compounds to degradation under ion bombardment allows explosive particles to be analyzed under high primary ion dose bombardment (dynamic SIMS) conditions, facilitating the rapid acquisition of spatially resolved molecular information. The use of cluster SIMS combined with computer control of the sample stage position allows for the automated identification and counting of explosive particle distributions on silicon surfaces. This will be useful for characterizing the efficiency of transfer of particulates in trace explosive detection portal collectors and/or swipes utilized for ion mobility spectrometry applications.

  7. SimVascular: An Open Source Pipeline for Cardiovascular Simulation.

    PubMed

    Updegrove, Adam; Wilson, Nathan M; Merkow, Jameson; Lan, Hongzhi; Marsden, Alison L; Shadden, Shawn C

    2017-03-01

    Patient-specific cardiovascular simulation has become a paradigm in cardiovascular research and is emerging as a powerful tool in basic, translational and clinical research. In this paper we discuss the recent development of a fully open-source SimVascular software package, which provides a complete pipeline from medical image data segmentation to patient-specific blood flow simulation and analysis. This package serves as a research tool for cardiovascular modeling and simulation, and has contributed to numerous advances in personalized medicine, surgical planning and medical device design. The SimVascular software has recently been refactored and expanded to enhance functionality, usability, efficiency and accuracy of image-based patient-specific modeling tools. Moreover, SimVascular previously required several licensed components that hindered new user adoption and code management and our recent developments have replaced these commercial components to create a fully open source pipeline. These developments foster advances in cardiovascular modeling research, increased collaboration, standardization of methods, and a growing developer community.

  8. Identification of diazotrophic microorganisms in marine sediment via fluorescence in situ hybridization coupled to nanoscale secondary ion mass spectrometry (FISH-NanoSIMS).

    PubMed

    Dekas, Anne E; Orphan, Victoria J

    2011-01-01

    Growing appreciation for the biogeochemical significance of uncultured microorganisms is changing the focus of environmental microbiology. Techniques designed to investigate microbial metabolism in situ are increasingly popular, from mRNA-targeted fluorescence in situ hybridization (FISH) to the "-omics" revolution, including metagenomics, transcriptomics, and proteomics. Recently, the coupling of FISH with nanometer-scale secondary ion mass spectrometry (NanoSIMS) has taken this movement in a new direction, allowing single-cell metabolic analysis of uncultured microbial phylogenic groups. The main advantage of FISH-NanoSIMS over previous noncultivation-based techniques to probe metabolism is its ability to directly link 16S rRNA phylogenetic identity to metabolic function. In the following chapter, we describe the procedures necessary to identify nitrogen-fixing microbes within marine sediment via FISH-NanoSIMS, using our work on nitrogen fixation by uncultured deep-sea methane-consuming archaea as a case study. Copyright © 2011 Elsevier Inc. All rights reserved.

  9. Rapid determination of organochlorine pesticides and polychlorinated biphenyls, using selected ion monitoring mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hargesheimer, E.E.

    Methane chemical ionization (CI)-selected ion monitoring (SIM) mass spectrometry was used to identify and conclusively distinguish 19 organochlorine pesticides from polychlorinated biphenyls (PCBs) at parts-per-trillion to parts-per-billion levels in environmental water sample extracts with minimal sample cleanup. Two CI-SIM screens were developed. One set of ions scanned specifically for the presence of 4 classes of pesticides; diphenylmethane derivatives, bridged polycyclic chlorinated benzenes, and acetanilide pesticides. The second set of ions responded exclusively to PCBs with biphenyl moieties containing from 1 to 8 chlorine atoms. Eight commercial Aroclor mixtures were analyzed and distinguished from the pesticides groups. The detection limit formore » pesticides and PCBs by CI-SIM screening was 0.005 and 0.1 ppB, respectively. CI-SIM can be used as an alternative method for the analysis of biological or environmental samples containing interferences that complicate the detection of PCBs and chlorinated pesticides. 8 references, 6 figures, 6 tables.« less

  10. Co-clustering directed graphs to discover asymmetries and directional communities

    PubMed Central

    Rohe, Karl; Qin, Tai; Yu, Bin

    2016-01-01

    In directed graphs, relationships are asymmetric and these asymmetries contain essential structural information about the graph. Directed relationships lead to a new type of clustering that is not feasible in undirected graphs. We propose a spectral co-clustering algorithm called di-sim for asymmetry discovery and directional clustering. A Stochastic co-Blockmodel is introduced to show favorable properties of di-sim. To account for the sparse and highly heterogeneous nature of directed networks, di-sim uses the regularized graph Laplacian and projects the rows of the eigenvector matrix onto the sphere. A nodewise asymmetry score and di-sim are used to analyze the clustering asymmetries in the networks of Enron emails, political blogs, and the Caenorhabditis elegans chemical connectome. In each example, a subset of nodes have clustering asymmetries; these nodes send edges to one cluster, but receive edges from another cluster. Such nodes yield insightful information (e.g., communication bottlenecks) about directed networks, but are missed if the analysis ignores edge direction. PMID:27791058

  11. Co-clustering directed graphs to discover asymmetries and directional communities.

    PubMed

    Rohe, Karl; Qin, Tai; Yu, Bin

    2016-10-21

    In directed graphs, relationships are asymmetric and these asymmetries contain essential structural information about the graph. Directed relationships lead to a new type of clustering that is not feasible in undirected graphs. We propose a spectral co-clustering algorithm called di-sim for asymmetry discovery and directional clustering. A Stochastic co-Blockmodel is introduced to show favorable properties of di-sim To account for the sparse and highly heterogeneous nature of directed networks, di-sim uses the regularized graph Laplacian and projects the rows of the eigenvector matrix onto the sphere. A nodewise asymmetry score and di-sim are used to analyze the clustering asymmetries in the networks of Enron emails, political blogs, and the Caenorhabditis elegans chemical connectome. In each example, a subset of nodes have clustering asymmetries; these nodes send edges to one cluster, but receive edges from another cluster. Such nodes yield insightful information (e.g., communication bottlenecks) about directed networks, but are missed if the analysis ignores edge direction.

  12. SimPhospho: a software tool enabling confident phosphosite assignment.

    PubMed

    Suni, Veronika; Suomi, Tomi; Tsubosaka, Tomoya; Imanishi, Susumu Y; Elo, Laura L; Corthals, Garry L

    2018-03-27

    Mass spectrometry combined with enrichment strategies for phosphorylated peptides has been successfully employed for two decades to identify sites of phosphorylation. However, unambiguous phosphosite assignment is considered challenging. Given that site-specific phosphorylation events function as different molecular switches, validation of phosphorylation sites is of utmost importance. In our earlier study we developed a method based on simulated phosphopeptide spectral libraries, which enables highly sensitive and accurate phosphosite assignments. To promote more widespread use of this method, we here introduce a software implementation with improved usability and performance. We present SimPhospho, a fast and user-friendly tool for accurate simulation of phosphopeptide tandem mass spectra. Simulated phosphopeptide spectral libraries are used to validate and supplement database search results, with a goal to improve reliable phosphoproteome identification and reporting. The presented program can be easily used together with the Trans-Proteomic Pipeline and integrated in a phosphoproteomics data analysis workflow. SimPhospho is available for Windows, Linux and Mac operating systems at https://sourceforge.net/projects/simphospho/. It is open source and implemented in C ++. A user's manual with detailed description of data analysis using SimPhospho as well as test data can be found as supplementary material of this article. Supplementary data are available at https://www.btk.fi/research/ computational-biomedicine/software/.

  13. Investigation of anodic TiO2 nanotube composition with high spatial resolution AES and ToF SIMS

    NASA Astrophysics Data System (ADS)

    Dronov, Alexey; Gavrilin, Ilya; Kirilenko, Elena; Dronova, Daria; Gavrilov, Sergey

    2018-03-01

    High resolution Scanning Auger Electron Spectroscopy (AES) and Time-of-Flight Secondary Ion Mass-Spectrometry (ToF SIMS) were used to investigate structure and elemental composition variation of both across an array of TiO2 nanotubes (NTs) and single tube of an array. The TiO2 NT array was grown by anodic oxidation of Ti foil in fluorine-containing ethylene glycol electrolyte. It was found that the studied anodic TiO2 nanotubes have a layered structure with rather sharp interfaces. The differences in AES depth profiling results of a single tube with the focused primary electron beam (point analysis) and over an area of 75 μm in diameter of a nanotube array with the defocused primary electron beam are discussed. Depth profiling by ToF SIMS was carried out over approximately the same size of a nanotube array to determine possible ionic fragments in the structure. The analysis results show that the combination of both mentioned methods is useful for a detailed analysis of nanostructures with complex morphology and multi-layered nature.

  14. Rapid discrimination of the causal agents of urinary tract infection using ToF-SIMS with chemometric cluster analysis

    NASA Astrophysics Data System (ADS)

    Fletcher, John S.; Henderson, Alexander; Jarvis, Roger M.; Lockyer, Nicholas P.; Vickerman, John C.; Goodacre, Royston

    2006-07-01

    Advances in time of flight secondary ion mass spectrometry (ToF-SIMS) have enabled this technique to become a powerful tool for the analysis of biological samples. Such samples are often very complex and as a result full interpretation of the acquired data can be extremely difficult. To simplify the interpretation of these information rich data, the use of chemometric techniques is becoming widespread in the ToF-SIMS community. Here we discuss the application of principal components-discriminant function analysis (PC-DFA) to the separation and classification of a number of bacterial samples that are known to be major causal agents of urinary tract infection. A large data set has been generated using three biological replicates of each isolate and three machine replicates were acquired from each biological replicate. Ordination plots generated using the PC-DFA are presented demonstrating strain level discrimination of the bacteria. The results are discussed in terms of biological differences between certain species and with reference to FT-IR, Raman spectroscopy and pyrolysis mass spectrometric studies of similar samples.

  15. Amyloid-β Plaques in Clinical Alzheimer’s Disease Brain Incorporate Stable Isotope Tracer In Vivo and Exhibit Nanoscale Heterogeneity

    PubMed Central

    Wildburger, Norelle C.; Gyngard, Frank; Guillermier, Christelle; Patterson, Bruce W.; Elbert, Donald; Mawuenyega, Kwasi G.; Schneider, Theresa; Green, Karen; Roth, Robyn; Schmidt, Robert E.; Cairns, Nigel J.; Benzinger, Tammie L. S.; Steinhauser, Matthew L.; Bateman, Randall J.

    2018-01-01

    Alzheimer’s disease (AD) is a neurodegenerative disorder with clinical manifestations of progressive memory decline and loss of executive function and language. AD affects an estimated 5.3 million Americans alone and is the most common form of age-related dementia with a rapidly growing prevalence among the aging population—those 65 years of age or older. AD is characterized by accumulation of aggregated amyloid-beta (Aβ) in the brain, which leads to one of the pathological hallmarks of AD—Aβ plaques. As a result, Aβ plaques have been extensively studied after being first described over a century ago. Advances in brain imaging and quantitative measures of Aβ in biological fluids have yielded insight into the time course of plaque development decades before and after AD symptom onset. However, despite the fundamental role of Aβ plaques in AD, in vivo measures of individual plaque growth, growth distribution, and dynamics are still lacking. To address this question, we combined stable isotope labeling kinetics (SILK) and nanoscale secondary ion mass spectrometry (NanoSIMS) imaging in an approach termed SILK–SIMS to resolve plaque dynamics in three human AD brains. In human AD brain, plaques exhibit incorporation of a stable isotope tracer. Tracer enrichment was highly variable between plaques and the spatial distribution asymmetric with both quiescent and active nanometer sub-regions of tracer incorporation. These data reveal that Aβ plaques are dynamic structures with deposition rates over days indicating a highly active process. Here, we report the first, direct quantitative measures of in vivo deposition into plaques in human AD brain. Our SILK–SIMS studies will provide invaluable information on plaque dynamics in the normal and diseased brain and offer many new avenues for investigation into pathological mechanisms of the disease, with implications for therapeutic development. PMID:29623063

  16. Amyloid-β Plaques in Clinical Alzheimer's Disease Brain Incorporate Stable Isotope Tracer In Vivo and Exhibit Nanoscale Heterogeneity.

    PubMed

    Wildburger, Norelle C; Gyngard, Frank; Guillermier, Christelle; Patterson, Bruce W; Elbert, Donald; Mawuenyega, Kwasi G; Schneider, Theresa; Green, Karen; Roth, Robyn; Schmidt, Robert E; Cairns, Nigel J; Benzinger, Tammie L S; Steinhauser, Matthew L; Bateman, Randall J

    2018-01-01

    Alzheimer's disease (AD) is a neurodegenerative disorder with clinical manifestations of progressive memory decline and loss of executive function and language. AD affects an estimated 5.3 million Americans alone and is the most common form of age-related dementia with a rapidly growing prevalence among the aging population-those 65 years of age or older. AD is characterized by accumulation of aggregated amyloid-beta (Aβ) in the brain, which leads to one of the pathological hallmarks of AD-Aβ plaques. As a result, Aβ plaques have been extensively studied after being first described over a century ago. Advances in brain imaging and quantitative measures of Aβ in biological fluids have yielded insight into the time course of plaque development decades before and after AD symptom onset. However, despite the fundamental role of Aβ plaques in AD, in vivo measures of individual plaque growth, growth distribution, and dynamics are still lacking. To address this question, we combined stable isotope labeling kinetics (SILK) and nanoscale secondary ion mass spectrometry (NanoSIMS) imaging in an approach termed SILK-SIMS to resolve plaque dynamics in three human AD brains. In human AD brain, plaques exhibit incorporation of a stable isotope tracer. Tracer enrichment was highly variable between plaques and the spatial distribution asymmetric with both quiescent and active nanometer sub-regions of tracer incorporation. These data reveal that Aβ plaques are dynamic structures with deposition rates over days indicating a highly active process. Here, we report the first, direct quantitative measures of in vivo deposition into plaques in human AD brain. Our SILK-SIMS studies will provide invaluable information on plaque dynamics in the normal and diseased brain and offer many new avenues for investigation into pathological mechanisms of the disease, with implications for therapeutic development.

  17. An investigation on the mechanism of sublimed DHB matrix on molecular ion yields in SIMS imaging of brain tissue.

    PubMed

    Dowlatshahi Pour, Masoumeh; Malmberg, Per; Ewing, Andrew

    2016-05-01

    We have characterized the use of sublimation to deposit matrix-assisted laser desorption/ionization (MALDI) matrices in secondary ion mass spectrometry (SIMS) analysis, i.e. matrix-enhanced SIMS (ME-SIMS), a common surface modification method to enhance sensitivity for larger molecules and to increase the production of intact molecular ions. We use sublimation to apply a thin layer of a conventional MALDI matrix, 2,5-dihydroxybenzoic acid (DHB), onto rat brain cerebellum tissue to show how this technique can be used to enhance molecular yields in SIMS while still retaining a lateral resolution around 2 μm and also to investigate the mechanism of this enhancement. The results here illustrate that cholesterol, which is a dominant lipid species in the brain, is decreased on the tissue surface after deposition of matrix, particularly in white matter. The decrease of cholesterol is followed by an increased ion yield of several other lipid species. Depth profiling of the sublimed rat brain reveals that the lipid species are de facto extracted by the DHB matrix and concentrated in the top most layers of the sublimed matrix. This extraction/concentration of lipids directly leads to an increase of higher mass lipid ion yield. It is also possible that the decrease of cholesterol decreases the potential suppression of ion yield caused by cholesterol migration to the tissue surface. This result provides us with significant insights into the possible mechanisms involved when using sublimation to deposit this matrix in ME-SIMS.

  18. Single-Cell Isolation of Circulating Tumor Cells from Whole Blood by Lateral Magnetophoretic Microseparation and Microfluidic Dispensing.

    PubMed

    Kim, Jinho; Cho, Hyungseok; Han, Song-I; Han, Ki-Ho

    2016-05-03

    This paper introduces a single-cell isolation technology for circulating tumor cells (CTCs) using a microfluidic device (the "SIM-Chip"). The SIM-Chip comprises a lateral magnetophoretic microseparator and a microdispenser as a two-step cascade platform. First, CTCs were enriched from whole blood by the lateral magnetophoretic microseparator based on immunomagnetic nanobeads. Next, the enriched CTCs were electrically identified by single-cell impedance cytometer and isolated as single cells using the microshooter. Using 200 μL of whole blood spiked with 50 MCF7 breast cancer cells, the analysis demonstrated that the single-cell isolation efficiency of the SIM-Chip was 82.4%, and the purity of the isolated MCF7 cells with respect to WBCs was 92.45%. The data also showed that the WBC depletion rate of the SIM-Chip was 2.5 × 10(5) (5.4-log). The recovery rates were around 99.78% for spiked MCF7 cells ranging in number from 10 to 90. The isolated single MCF7 cells were intact and could be used for subsequent downstream genetic assays, such as RT-PCR. Single-cell culture evaluation of the proliferation of MCF7 cells isolated by the SIM-Chip showed that 84.1% of cells at least doubled in 5 days. Consequently, the SIM-Chip could be used for single-cell isolation of rare target cells from whole blood with high purity and recovery without cell damage.

  19. High-resolution quantitative imaging of mammalian and bacterial cells using stable isotope mass spectrometry.

    PubMed

    Lechene, Claude; Hillion, Francois; McMahon, Greg; Benson, Douglas; Kleinfeld, Alan M; Kampf, J Patrick; Distel, Daniel; Luyten, Yvette; Bonventre, Joseph; Hentschel, Dirk; Park, Kwon Moo; Ito, Susumu; Schwartz, Martin; Benichou, Gilles; Slodzian, Georges

    2006-01-01

    Secondary-ion mass spectrometry (SIMS) is an important tool for investigating isotopic composition in the chemical and materials sciences, but its use in biology has been limited by technical considerations. Multi-isotope imaging mass spectrometry (MIMS), which combines a new generation of SIMS instrument with sophisticated ion optics, labeling with stable isotopes, and quantitative image-analysis software, was developed to study biological materials. The new instrument allows the production of mass images of high lateral resolution (down to 33 nm), as well as the counting or imaging of several isotopes simultaneously. As MIMS can distinguish between ions of very similar mass, such as 12C15N- and 13C14N-, it enables the precise and reproducible measurement of isotope ratios, and thus of the levels of enrichment in specific isotopic labels, within volumes of less than a cubic micrometer. The sensitivity of MIMS is at least 1,000 times that of 14C autoradiography. The depth resolution can be smaller than 1 nm because only a few atomic layers are needed to create an atomic mass image. We illustrate the use of MIMS to image unlabeled mammalian cultured cells and tissue sections; to analyze fatty-acid transport in adipocyte lipid droplets using 13C-oleic acid; to examine nitrogen fixation in bacteria using 15N gaseous nitrogen; to measure levels of protein renewal in the cochlea and in post-ischemic kidney cells using 15N-leucine; to study DNA and RNA co-distribution and uridine incorporation in the nucleolus using 15N-uridine and 81Br of bromodeoxyuridine or 14C-thymidine; to reveal domains in cultured endothelial cells using the native isotopes 12C, 16O, 14N and 31P; and to track a few 15N-labeled donor spleen cells in the lymph nodes of the host mouse. MIMS makes it possible for the first time to both image and quantify molecules labeled with stable or radioactive isotopes within subcellular compartments.

  20. Improving high resolution retinal image quality using speckle illumination HiLo imaging

    PubMed Central

    Zhou, Xiaolin; Bedggood, Phillip; Metha, Andrew

    2014-01-01

    Retinal image quality from flood illumination adaptive optics (AO) ophthalmoscopes is adversely affected by out-of-focus light scatter due to the lack of confocality. This effect is more pronounced in small eyes, such as that of rodents, because the requisite high optical power confers a large dioptric thickness to the retina. A recently-developed structured illumination microscopy (SIM) technique called HiLo imaging has been shown to reduce the effect of out-of-focus light scatter in flood illumination microscopes and produce pseudo-confocal images with significantly improved image quality. In this work, we adopted the HiLo technique to a flood AO ophthalmoscope and performed AO imaging in both (physical) model and live rat eyes. The improvement in image quality from HiLo imaging is shown both qualitatively and quantitatively by using spatial spectral analysis. PMID:25136486

  1. Improving high resolution retinal image quality using speckle illumination HiLo imaging.

    PubMed

    Zhou, Xiaolin; Bedggood, Phillip; Metha, Andrew

    2014-08-01

    Retinal image quality from flood illumination adaptive optics (AO) ophthalmoscopes is adversely affected by out-of-focus light scatter due to the lack of confocality. This effect is more pronounced in small eyes, such as that of rodents, because the requisite high optical power confers a large dioptric thickness to the retina. A recently-developed structured illumination microscopy (SIM) technique called HiLo imaging has been shown to reduce the effect of out-of-focus light scatter in flood illumination microscopes and produce pseudo-confocal images with significantly improved image quality. In this work, we adopted the HiLo technique to a flood AO ophthalmoscope and performed AO imaging in both (physical) model and live rat eyes. The improvement in image quality from HiLo imaging is shown both qualitatively and quantitatively by using spatial spectral analysis.

  2. Deuterium depth profile quantification in a ASDEX Upgrade divertor tile using secondary ion mass spectrometry

    NASA Astrophysics Data System (ADS)

    Ghezzi, F.; Caniello, R.; Giubertoni, D.; Bersani, M.; Hakola, A.; Mayer, M.; Rohde, V.; Anderle, M.; ASDEX Upgrade Team

    2014-10-01

    We present the results of a study where secondary ion mass spectrometry (SIMS) has been used to obtain depth profiles of deuterium concentration on plasma facing components of the first wall of the ASDEX Upgrade tokamak. The method uses primary and secondary standards to quantify the amount of deuterium retained. Samples of bulk graphite coated with tungsten or tantalum-doped tungsten are independently profiled with three different SIMS instruments. Their deuterium concentration profiles are compared showing good agreement. In order to assess the validity of the method, the integrated deuterium concentrations in the coatings given by one of the SIMS devices is compared with nuclear reaction analysis (NRA) data. Although in the case of tungsten the agreement between NRA and SIMS is satisfactory, for tantalum-doped tungsten samples the discrepancy is significant because of matrix effect induced by tantalum and differently eroded surface (W + Ta always exposed to plasma, W largely shadowed). A further comparison where the SIMS deuterium concentration is obtained by calibrating the measurements against NRA values is also presented. For the tungsten samples, where no Ta induced matrix effects are present, the two methods are almost equivalent.The results presented show the potential of the method provided that the standards used for the calibration reproduce faithfully the matrix nature of the samples.

  3. GUM Analysis for SIMS Isotopic Ratios in BEP0 Graphite Qualification Samples, Round 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gerlach, David C.; Heasler, Patrick G.; Reid, Bruce D.

    2009-01-01

    This report describes GUM calculations for TIMS and SIMS isotopic ratio measurements of reactor graphite samples. These isotopic ratios are used to estimate reactor burn-up, and currently consist of various ratios of U, Pu, and Boron impurities in the graphite samples. The GUM calculation is a propagation of error methodology that assigns uncertainties (in the form of standard error and confidence bound) to the final estimates.

  4. AES and SIMS analysis of non-metallic inclusions in a low-carbon chromium-steel.

    PubMed

    Gammer, Katharina; Rosner, M; Poeckl, G; Hutter, H

    2003-05-01

    In the final step of secondary metallurgical steel processing, calcium is added. Besides Mg, Ca is the most powerful deoxidiser and desulfurisation agent. It reacts with dissolved oxygen and sulfur and reduces oxides and sulfides thereby forming non-metallic inclusions. Within this paper we present the analysis of such inclusions in a low-carbon chromium-steel. Depending on the time of quenching of the steel sample, different structures were revealed by REM, Auger and SIMS: If the steel was quenched immediately after Ca-addition, non-metallic inclusions that appeared to have "cavities" could be detected with SEM. SIMS investigations of these particles showed ring-shaped structures and revealed that the ring is made up of Al, Ca, Mg, O and S. No secondary ions however could be retrieved from the core inside the ring, thus leaving the nature of the "cavities" unclear. If the steel sample was quenched 3 min after Ca addition, inclusions did not have a ring-shaped structure but a compact one.

  5. Model for Sucker-Rod Pumping Unit Operating Modes Analysis Based on SimMechanics Library

    NASA Astrophysics Data System (ADS)

    Zyuzev, A. M.; Bubnov, M. V.

    2018-01-01

    The article provides basic information about the process of a sucker-rod pumping unit (SRPU) model developing by means of SimMechanics library in the MATLAB Simulink environment. The model is designed for the development of a pump productivity optimal management algorithms, sensorless diagnostics of the plunger pump and pumpjack, acquisition of the dynamometer card and determination of a dynamic fluid level in the well, normalization of the faulty unit operation before troubleshooting is performed by staff as well as equilibrium ratio determining by energy indicators and outputting of manual balancing recommendations to achieve optimal power consumption efficiency. Particular attention is given to the application of various blocks from SimMechanics library to take into account the pumpjack construction principal characteristic and to obtain an adequate model. The article explains in depth the developed tools features for collecting and analysis of simulated mechanism data. The conclusions were drawn about practical implementation possibility of the SRPU modelling results and areas for further development of investigation.

  6. Interrogating marine virus-host interactions and elemental transfer with BONCAT and nanoSIMS-based methods.

    PubMed

    Pasulka, Alexis L; Thamatrakoln, Kimberlee; Kopf, Sebastian H; Guan, Yunbin; Poulos, Bonnie; Moradian, Annie; Sweredoski, Michael J; Hess, Sonja; Sullivan, Mathew B; Bidle, Kay D; Orphan, Victoria J

    2018-02-01

    While the collective impact of marine viruses has become more apparent over the last decade, a deeper understanding of virus-host dynamics and the role of viruses in nutrient cycling would benefit from direct observations at the single-virus level. We describe two new complementary approaches - stable isotope probing coupled with nanoscale secondary ion mass spectrometry (nanoSIMS) and fluorescence-based biorthogonal non-canonical amino acid tagging (BONCAT) - for studying the activity and biogeochemical influence of marine viruses. These tools were developed and tested using several ecologically relevant model systems (Emiliania huxleyi/EhV207, Synechococcus sp. WH8101/Syn1 and Escherichia coli/T7). By resolving carbon and nitrogen enrichment in viral particles, we demonstrate the power of nanoSIMS tracer experiments in obtaining quantitative estimates for the total number of viruses produced directly from a particular production pathway (by isotopically labelling host substrates). Additionally, we show through laboratory experiments and a pilot field study that BONCAT can be used to directly quantify viral production (via epifluorescence microscopy) with minor sample manipulation and no dependency on conversion factors. This technique can also be used to detect newly synthesized viral proteins. Together these tools will help fill critical gaps in our understanding of the biogeochemical impact of viruses in the ocean. © 2017 Society for Applied Microbiology and John Wiley & Sons Ltd.

  7. Strategy to improve the quantitative LC-MS analysis of molecular ions resistant to gas-phase collision induced dissociation: application to disulfide-rich cyclic peptides.

    PubMed

    Ciccimaro, Eugene; Ranasinghe, Asoka; D'Arienzo, Celia; Xu, Carrie; Onorato, Joelle; Drexler, Dieter M; Josephs, Jonathan L; Poss, Michael; Olah, Timothy

    2014-12-02

    Due to observed collision induced dissociation (CID) fragmentation inefficiency, developing sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) assays for CID resistant compounds is especially challenging. As an alternative to traditional LC-MS/MS, we present here a methodology that preserves the intact analyte ion for quantification by selectively filtering ions while reducing chemical noise. Utilizing a quadrupole-Orbitrap MS, the target ion is selectively isolated while interfering matrix components undergo MS/MS fragmentation by CID, allowing noise-free detection of the analyte's surviving molecular ion. In this manner, CID affords additional selectivity during high resolution accurate mass analysis by elimination of isobaric interferences, a fundamentally different concept than the traditional approach of monitoring a target analyte's unique fragment following CID. This survivor-selected ion monitoring (survivor-SIM) approach has allowed sensitive and specific detection of disulfide-rich cyclic peptides extracted from plasma.

  8. Amphetamine concentrations in human urine following single-dose administration of the calcium antagonist prenylamine-studies using fluorescence polarization immunoassay (FPIA) and GC-MS.

    PubMed

    Kraemer, Thomas; Roditis, Susanne K; Peters, Frank T; Maurer, Hans H

    2003-03-01

    Prenylamine (R,S-N-(3,3-diphenylpropyl-methyl-2-phenethylamine), a World Health Organization class V calcium antagonist, is known to be metabolized to amphetamine. In this study, amphetamine concentrations after a single-dose administration of prenylamine were determined to check if they reached values that could be of analytical and/or pharmacological importance in clinical and forensic toxicology. Enantiomeric composition of amphetamine was also studied. Five volunteers received a single 120-mg oral dose of prenylamine. Urine samples were analyzed using the Abbott TDx immunoassay Amphetamine/Methamphetamine II and using our routine systematic toxicological analysis (STA) gas chromatography-mass spectrometry (GC-MS) procedure. For quantitation purposes, GC-MS was used in the selected-ion monitoring (SIM) mode (ions m/z 118, 122, 240, 244) after solid-phase extraction (Isolute Confirm HCX) and derivatization (heptafluorobutyric anhydride). Amphetamine-d5 was used as internal standard (IS). Chiral separation of the heptafluorobutyrated amphetamine enantiomers was achieved using an Astec Chiraldex G-PN column. The TDx results showed a great variability for the different volunteers. A urine sample of one volunteer showed results as high as 3200 ng/mL, whereas the urine samples of another volunteer never gave results greater than the TDx detection limit (100 ng/mL). Using the STA procedure, the presence of amphetamine could be confirmed in all urine samples with TDx results greater than the cutoff value (300 ng/mL). Using the GC-MS SIM method, amphetamine concentrations up to 1280 ng/mL were determined. Chiral analysis revealed that both enantiomers of amphetamine were present in the samples with a surplus of the S(+)-enantiomer in the early phase of excretion. Forensic implications are discussed.

  9. Local Non-Esterified Fatty Acids Correlate With Inflammation in Atheroma Plaques of Patients With Type 2 Diabetes

    PubMed Central

    Mas, Sebastián; Martínez-Pinna, Roxana; Martín-Ventura, Jose Luis; Pérez, Raul; Gomez-Garre, Dulcenombre; Ortiz, Alberto; Fernandez-Cruz, Arturo; Vivanco, Fernando; Egido, Jesús

    2010-01-01

    OBJECTIVE Atherosclerosis is prevalent in diabetic patients, but there is little information on the localization of nonesterified fatty acids (NEFAs) within the plaque and their relationship with inflammation. We sought to characterize the NEFA composition and location in human diabetic atheroma plaques by metabolomic analysis and imaging and to address their relationship with inflammation activity. RESEARCH DESIGN AND METHODS Time-of-flight secondary ion mass spectrometry (TOF-SIMS) was used for metabolomic analysis imaging of frozen carotid atheroma plaques. Carotid endarterectomy specimens were used for conventional immunohistochemistry, laser-capture microdissection quantitative PCR, and in situ Southwestern hybridization. Biological actions of linoleic acid were studied in cultured vascular smooth muscle cells (VSMCs). RESULTS TOF-SIMS imaging evidenced a significant increase in the quantity of several NEFA in diabetic versus nondiabetic atheroma plaques. Higher levels of NEFA were also found in diabetic sera. The presence of LPL mRNA in NEFA-rich areas of the atheroma plaque, as well as the lack of correlation between serum and plaque NEFA, suggests a local origin for plaque NEFA. The pattern of distribution of plaque NEFA is similar to that of MCP-1, LPL, and activated NF-κB. Diabetic endarterectomy specimens showed higher numbers of infiltrating macrophages and T-lymphocytes—a finding that associated with higher NEFA levels. Finally, linoleic acid activates NF-κB and upregulates NF-κB–mediated LPL and MCP-1 expression in cultured VSMC. DISCUSSION There is an increased presence of NEFA in diabetic plaque neointima. NEFA levels are higher in diabetic atheroma plaques than in nondiabetic subjects. We hypothesize that NEFA may be produced locally and contribute to local inflammation. PMID:20200316

  10. Analysis of antioxidants in insulation cladding of copper wire: a comparison of different mass spectrometric techniques (ESI-IT, MALDI-RTOF and RTOF-SIMS).

    PubMed

    Schnöller, Johannes; Pittenauer, Ernst; Hutter, Herbert; Allmaier, Günter

    2009-12-01

    Commercial copper wire and its polymer insulation cladding was investigated for the presence of three synthetic antioxidants (ADK STAB AO412S, Irganox 1010 and Irganox MD 1024) by three different mass spectrometric techniques including electrospray ionization-ion trap-mass spectrometry (ESI-IT-MS), matrix-assisted laser desorption/ionization reflectron time-of-flight (TOF) mass spectrometry (MALDI-RTOF-MS) and reflectron TOF secondary ion mass spectrometry (RTOF-SIMS). The samples were analyzed either directly without any treatment (RTOF-SIMS) or after a simple liquid/liquid extraction step (ESI-IT-MS, MALDI-RTOF-MS and RTOF-SIMS). Direct analysis of the copper wire itself or of the insulation cladding by RTOF-SIMS allowed the detection of at least two of the three antioxidants but at rather low sensitivity as molecular radical cations and with fairly strong fragmentation (due to the highly energetic ion beam of the primary ion gun). ESI-IT- and MALDI-RTOF-MS-generated abundant protonated and/or cationized molecules (ammoniated or sodiated) from the liquid/liquid extract. Only ESI-IT-MS allowed simultaneous detection of all three analytes in the extract of insulation claddings. The latter two so-called 'soft' desorption/ionization techniques exhibited intense fragmentation only by applying low-energy collision-induced dissociation (CID) tandem MS on a multistage ion trap-instrument and high-energy CID on a tandem TOF-instrument (TOF/RTOF), respectively. Strong differences in the fragmentation behavior of the three analytes could be observed between the different CID spectra obtained from either the IT-instrument (collision energy in the very low eV range) or the TOF/RTOF-instrument (collision energy 20 keV), but both delivered important structural information. Copyright 2009 John Wiley & Sons, Ltd.

  11. Cyto-Sim: a formal language model and stochastic simulator of membrane-enclosed biochemical processes.

    PubMed

    Sedwards, Sean; Mazza, Tommaso

    2007-10-15

    Compartments and membranes are the basis of cell topology and more than 30% of the human genome codes for membrane proteins. While it is possible to represent compartments and membrane proteins in a nominal way with many mathematical formalisms used in systems biology, few, if any, explicitly model the topology of the membranes themselves. Discrete stochastic simulation potentially offers the most accurate representation of cell dynamics. Since the details of every molecular interaction in a pathway are often not known, the relationship between chemical species in not necessarily best described at the lowest level, i.e. by mass action. Simulation is a form of computer-aided analysis, relying on human interpretation to derive meaning. To improve efficiency and gain meaning in an automatic way, it is necessary to have a formalism based on a model which has decidable properties. We present Cyto-Sim, a stochastic simulator of membrane-enclosed hierarchies of biochemical processes, where the membranes comprise an inner, outer and integral layer. The underlying model is based on formal language theory and has been shown to have decidable properties (Cavaliere and Sedwards, 2006), allowing formal analysis in addition to simulation. The simulator provides variable levels of abstraction via arbitrary chemical kinetics which link to ordinary differential equations. In addition to its compact native syntax, Cyto-Sim currently supports models described as Petri nets, can import all versions of SBML and can export SBML and MATLAB m-files. Cyto-Sim is available free, either as an applet or a stand-alone Java program via the web page (http://www.cosbi.eu/Rpty_Soft_CytoSim.php). Other versions can be made available upon request.

  12. QuakeSim 2.0

    NASA Technical Reports Server (NTRS)

    Donnellan, Andrea; Parker, Jay W.; Lyzenga, Gregory A.; Granat, Robert A.; Norton, Charles D.; Rundle, John B.; Pierce, Marlon E.; Fox, Geoffrey C.; McLeod, Dennis; Ludwig, Lisa Grant

    2012-01-01

    QuakeSim 2.0 improves understanding of earthquake processes by providing modeling tools and integrating model applications and various heterogeneous data sources within a Web services environment. QuakeSim is a multisource, synergistic, data-intensive environment for modeling the behavior of earthquake faults individually, and as part of complex interacting systems. Remotely sensed geodetic data products may be explored, compared with faults and landscape features, mined by pattern analysis applications, and integrated with models and pattern analysis applications in a rich Web-based and visualization environment. Integration of heterogeneous data products with pattern informatics tools enables efficient development of models. Federated database components and visualization tools allow rapid exploration of large datasets, while pattern informatics enables identification of subtle, but important, features in large data sets. QuakeSim is valuable for earthquake investigations and modeling in its current state, and also serves as a prototype and nucleus for broader systems under development. The framework provides access to physics-based simulation tools that model the earthquake cycle and related crustal deformation. Spaceborne GPS and Inter ferometric Synthetic Aperture (InSAR) data provide information on near-term crustal deformation, while paleoseismic geologic data provide longerterm information on earthquake fault processes. These data sources are integrated into QuakeSim's QuakeTables database system, and are accessible by users or various model applications. UAVSAR repeat pass interferometry data products are added to the QuakeTables database, and are available through a browseable map interface or Representational State Transfer (REST) interfaces. Model applications can retrieve data from Quake Tables, or from third-party GPS velocity data services; alternatively, users can manually input parameters into the models. Pattern analysis of GPS and seismicity data has proved useful for mid-term forecasting of earthquakes, and for detecting subtle changes in crustal deformation. The GPS time series analysis has also proved useful as a data-quality tool, enabling the discovery of station anomalies and data processing and distribution errors. Improved visualization tools enable more efficient data exploration and understanding. Tools provide flexibility to science users for exploring data in new ways through download links, but also facilitate standard, intuitive, and routine uses for science users and end users such as emergency responders.

  13. The GP tests of competence assessment: which part best predicts fitness to practise decisions?

    PubMed

    Jayaweera, Hirosha Keshani; Potts, Henry W W; Keshwani, Karim; Valerio, Chris; Baker, Magdalen; Mehdizadeh, Leila; Sturrock, Alison

    2018-01-02

    The General Medical Council (GMC) conducts Tests of Competence (ToC) for doctors referred for Fitness to Practise (FtP) issues. GPs take a single best answer knowledge test, an Objective Structured Clinical Examination (OSCE), and a Simulated Surgery (SimSurg) assessment which is a simulated GP consultation. The aim of this study was to examine the similarities between OSCEs and SimSurg to determine whether each assessment contributed something unique to GP ToCs. A mixed methods approach was used. Data were collated on 153 GPs who were required to undertake a ToC as a part of being investigated for FtP issues between February 2010 and October 2016. Using correlation analysis, we examined to what degree performance on the knowledge test, OSCE, and SimSurg related to case examiner recommendations and FtP outcomes, including the unique predictive power of these three assessments. The outcome measures were case examiner recommendations (i) not fit to practise; ii) fit to practise on a limited basis; or iii) fit to practise) as well as FtP outcomes (i) erased/removed from the register; ii) having restrictions/conditions; or iii) be in good standing). For the qualitative component, 45 GP assessors were asked to rate whether they assess the same competencies and which assessment provides better feedback about candidates. There was significant overlap between OSCEs and SimSurg, p < 0.001. SimSurg had additional predictive power in the presence of OSCEs and the knowledge test (p = 0.030) in distinguishing doctors from different FtP categories, while OSCEs did not (p = 0.080). Both the OSCEs (p = 0.004) and SimSurg (p < 0.001) had significant negative correlations with case examiner recommendations when accounting for the effects of the other two assessments. Inductive thematic analysis of the responses to the questionnaire showed that assessors perceived OSCEs to be better suited to target specific knowledge and skills. SimSurg was thought to produce a more global picture as the scenarios more accurately portray a patient consultation. While all three assessments are strong predictors of both case examiner recommendations and FtP outcomes, our findings suggest that the efficiency of GP ToCs can be improved by removing some of this overlapping content.

  14. Surface science analysis of GaAs photocathodes following sustained electron beam delivery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carlos Hernandez-Garcia, Fay Hannon, Marcy Stutzman, V. Shutthanandan, Z. Zhu, M. Nandasri, S. V. Kuchibhatla, S. Thevuthasan, W. P. Hess

    2012-06-01

    Degradation of the photocathode materials employed in photoinjectors represents a challenge for sustained operation of nuclear physics accelerators and high power Free Electron Lasers (FEL). Photocathode quantum efficiency (QE) degradation is due to residual gasses in the electron source vacuum system being ionized and accelerated back to the photocathode. These investigations are a first attempt to characterize the nature of the photocathode degradation, and employ multiple surface and bulk analysis techniques to investigate damage mechanisms including sputtering of the Cs-oxidant surface monolayer, other surface chemistry effects, and ion implantation. Surface and bulk analysis studies were conducted on two GaAs photocathodes,more » which were removed from the JLab FEL DC photoemission gun after delivering electron beam, and two control samples. The analysis techniques include Helium Ion Microscopy (HIM), Rutherford Backscattering Spectrometry (RBS), Atomic Force Microscopy (AFM) and Secondary Ion Mass Spectrometry (SIMS). In addition, two high-polarization strained superlattice GaAs photocathode samples, one removed from the Continuous Electron Beam Accelerator Facility (CEBAF) photoinjector and one unused, were also analyzed using Transmission Electron Microscopy (TEM) and SIMS. It was found that heat cleaning the FEL GaAs wafer introduces surface roughness, which seems to be reduced by prolonged use. The bulk GaAs samples retained a fairly well organized crystalline structure after delivering beam but shows evidence of Cs depletion on the surface. Within the precision of the SIMS and RBS measurements the data showed no indication of hydrogen implantation or lattice damage from ion back bombardment in the bulk GaAs wafers. In contrast, SIMS and TEM measurements of the strained superlattice photocathode show clear crystal damage in the wafer from ion back bombardment.« less

  15. Simultaneous versus sequential bilateral cochlear implants in adults: Cost analysis in a US setting.

    PubMed

    Trinidade, Aaron; Page, Joshua C; Kennett, Sarah W; Cox, Matthew D; Dornhoffer, John L

    2017-11-01

    From a purely surgical efficiency point of view, simultaneous cochlear implantation (SimCI) is more cost-effective than sequential cochlear implantation (SeqCI) when total direct costs are considered (implant and hospital costs). However, in a setting where only SeqCI is practiced and a proportion of initially unilaterally implanted patients do not progress to a second implant, this may not be the case, especially when audiological costs are factored in. We present a cost analysis of such a scenario as would occur in our institution. Retrospective review and cost analysis. Between 2005 and 2015, 370 patients fulfilled the audiological criteria for bilateral implantation. Of those, 267 (72.1%) underwent unilateral cochlear implantation only, 101 (27.3%) progressed to SeqCI, and two underwent SimCI. The total hospital, surgical, and implant costs, and initial implant stimulation series audiological costs between August 2015 and August 2016 (29 adult patients) were used in this analysis. The total hospital, surgical, and implant costs for this period was $2,731,360.42. Based on previous local trends, if a projected eight (27.3%) of these patients decide to progress to SeqCI, this will cost an additional $750,811.04, resulting in an overall total of $3,482,171.46 for these 29 patients. Had all 29 undergone SimCI, the total projected cost would have been $3,332,991.75, representing a total potential saving of $149,179.67 (4.3%). In institutions where only SeqCI is allowed in adults, overall patient management may cost marginally more than if SimCI were practiced. This will be of interest to CI programs and health insurance companies. 4. Laryngoscope, 127:2615-2618, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  16. Understanding the Interface Dipole of Copper Phthalocyanine (CuPc)/C60: Theory and Experiment.

    PubMed

    Sai, Na; Gearba, Raluca; Dolocan, Andrei; Tritsch, John R; Chan, Wai-Lun; Chelikowsky, James R; Leung, Kevin; Zhu, Xiaoyang

    2012-08-16

    Interface dipole determines the electronic energy alignment in donor/acceptor interfaces and plays an important role in organic photovoltaics. Here we present a study combining first principles density functional theory (DFT) with ultraviolet photoemission spectroscopy (UPS) and time-of-flight secondary ion mass spectrometry (TOF-SIMS) to investigate the interface dipole, energy level alignment, and structural properties at the interface between CuPc and C60. DFT finds a sizable interface dipole for the face-on orientation, in quantitative agreement with the UPS measurement, and rules out charge transfer as the origin of the interface dipole. Using TOF-SIMS, we show that the interfacial morphology for the bilayer CuPc/C60 film is characterized by molecular intermixing, containing both the face-on and the edge-on orientation. The complementary experimental and theoretical results provide both insight into the origin of the interface dipole and direct evidence for the effect of interfacial morphology on the interface dipole.

  17. Development of an indirect enzyme linked immunoassay for abscisic acid. [Pisum sativum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ross, G.S.; Elder, P.A.; McWha, J.A.

    1987-09-01

    AN INDIRECT METHOD OF ENZYME-LINKED-IMMUNOSORBENT-ASSAY (ELISA) IS REPORTED FOR ABSCISIC ACID (ABA), UTILIZING A THYROGLOBULIN-ABA CONJUGATE FOR COATING WELLS. THE ASSAY CAN USE COMMERCIALLY AVAILABLE MONOCLONAL ANTIBODIES, IS SENSITIVE TO AS LITTLE AS 20 PICOGRAMS ABA PER WELL, AND IS MUCH MORE CONSERVATIVE OF ANTIBODY THAN DIRECT METHODS. THE MOST DILUTE ABA STANDARDS DID NOT RETAIN THEIR ANTIGENICITY DURING STORAGE, SO ABA STANDARD SETS WERE DILUTED IMMEDIATELY PRIOR TO USE. THE INDIRECT ELISA WAS USED SUCCESSFULLY TO ESTIMATE ABA CONCENTRATIONS IN DEVELOPING COTYLEDONS OF PISUM SATIVUM L., AFTER ONLY LITTLE PRELIMINARY PURIFICATION. IT WAS VALIDATED FOR THIS TISSUE THROUGH THEmore » USE OF GAS CHROMATOGRAPHY-ELECTRON CAPTURE DETECTION (GC-EC), AND CAPILLARY GC-SELECTED ION MONITORING (GC-MS-SIM) USING LABELLED ABA AS AN INTERNAL STANDARD. FULL SPECTRUM GC-MASS SPECTROMETRY WAS ALSO USED TO VERIFY THAT ABA WAS PRESENT IN A SAMPLE ASSAYED QUANTITATIVELY BY BOTH ELISA AND GC-MS-SIM.« less

  18. Extreme isotopologue disequilibrium in molecular SIMS species during SHRIMP geochronology

    NASA Astrophysics Data System (ADS)

    Magee, Charles W., Jr.; Danišík, Martin; Mernagh, Terry

    2017-12-01

    The current limitation in the accuracy and precision of inter-element analysis in secondary ion mass spectrometry (SIMS) is the ability to find measurable quantities that allow relative differences in ionization and transmission efficiency of secondary ions to be normalized. In uranium-thorium-lead geochronology, the ability to make these corrections, or "calibrate" the data, results in an accuracy limit of approximately 1 %. This study looks at the ionization of uranium and thorium oxide species, which are traditionally used in U-Pb calibration, to explore the conditions under which isotopologues, or molecular species whose composition differs only in the isotopic composition of one or more atoms in the molecule, remain in or deviate from equilibrium. Isotopologue deficits of up to 0.2 (200 ‰) below ideal mixing are observed in UO2+ species during SIMS gechronological analyses using the SHRIMP IIe SIMS instrument. These are identified by bombarding natural U-bearing minerals with an 18O2- primary beam. The large anomalies are associated with repeat analyses down a single SIMS sputtering crater (Compston et al., 1984), analysis of high-uranium, radiation-damaged zircon, and analysis of baddeleyite. Analysis of zircon under routine conditions yield UO2+ isotopologue anomalies generally within a few percent of equilibrium. The conditions under which the isotopologue anomalies are observed are also conditions in which the UOx-based corrections, or calibration, for relative U vs. Pb ionization efficiencies fail. The existence of these isotopologue anomalies suggest that failure of the various UOx species to equilibrate with each other is the reason that none of them will successfully correct the U  / Pb ratio. No simple isotopologue-based correction is apparent. However, isotopologue disequilibrium appears to be a more sensitive tool for detecting high-U calibration breakdowns than Raman spectroscopy, which showed sharper peaks for ˜ 37 Ma high-uranium zircons than for reference zircons OG1 and Temora. U-Th-Sm / He ages were determined for aliquots of reference zircons OG1 (755±71 Ma) and Temora (323±43 Ma), suggesting that the broader Raman lines for the Temora reference zircons may be due to something other than accumulated radiation damage. Isotopologue abundances for UO+ and ThO+ and their energy spectra are consistent with most or all molecular species being the product of atomic recombination when the primary beam impact energy is greater than 5.7 keV. This, in addition to the large UO2+ instrumentally generated isotopologue disequilibria, suggests that any attempts to use SIMS to detect naturally occurring isotopologue deviations could be tricky.

  19. Synchrotron based mass spectrometry to investigate the molecular properties of mineral-organic associations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Suet Yi; Kleber, Markus; Takahashi, Lynelle K.

    2013-04-01

    Soil organic matter (OM) is important because its decay drives life processes in the biosphere. Analysis of organic compounds in geological systems is difficult because of their intimate association with mineral surfaces. To date there is no procedure capable of quantitatively separating organic from mineral phases without creating artifacts or mass loss. Therefore, analytical techniques that can (a) generate information about both organic and mineral phases simultaneously and (b) allow the examination of predetermined high-interest regions of the sample as opposed to conventional bulk analytical techniques are valuable. Laser Desorption Synchrotron Postionization (synchrotron-LDPI) mass spectrometry is introduced as a novelmore » analytical tool to characterize the molecular properties of organic compounds in mineral-organic samples from terrestrial systems, and it is demonstrated that when combined with Secondary Ion Mass Spectrometry (SIMS), can provide complementary information on mineral composition. Mass spectrometry along a decomposition gradient in density fractions, verifies the consistency of our results with bulk analytical techniques. We further demonstrate that by changing laser and photoionization energies, variations in molecular stability of organic compounds associated with mineral surfaces can be determined. The combination of synchrotron-LDPI and SIMS shows that the energetic conditions involved in desorption and ionization of organic matter may be a greater determinant of mass spectral signatures than the inherent molecular structure of the organic compounds investigated. The latter has implications for molecular models of natural organic matter that are based on mass spectrometric information.« less

  20. Dynamic secondary ion mass spectroscopy of Au nanoparticles on Si wafer using Bi3+ as primary ion coupled with surface etching by Ar cluster ion beam: The effect of etching conditions on surface structure

    NASA Astrophysics Data System (ADS)

    Park, Eun Ji; Choi, Chang Min; Kim, Il Hee; Kim, Jung-Hwan; Lee, Gaehang; Jin, Jong Sung; Ganteför, Gerd; Kim, Young Dok; Choi, Myoung Choul

    2018-01-01

    Wet-chemically synthesized Au nanoparticles were deposited on Si wafer surfaces, and the secondary ions mass spectra (SIMS) from these samples were collected using Bi3+ with an energy of 30 keV as the primary ions. In the SIMS, Au cluster cations with a well-known, even-odd alteration pattern in the signal intensity were observed. We also performed depth profile SIMS analyses, i.e., etching the surface using an Ar gas cluster ion beam (GCIB), and a subsequent Bi3+ SIMS analysis was repetitively performed. Here, two different etching conditions (Ar1600 clusters of 10 keV energy or Ar1000 of 2.5 keV denoted as "harsh" or "soft" etching conditions, respectively) were used. Etching under harsh conditions induced emission of the Au-Si binary cluster cations in the SIMS spectra of the Bi3+ primary ions. The formation of binary cluster cations can be induced by either fragmentation of Au nanoparticles or alloying of Au and Si, increasing Au-Si coordination on the sample surface during harsh GCIB etching. Alternatively, use of the soft GCIB etching conditions resulted in exclusive emission of pure Au cluster cations with nearly no Au-Si cluster cation formation. Depth profile analyses of the Bi3+ SIMS combined with soft GCIB etching can be useful for studying the chemical environments of atoms at the surface without altering the original interface structure during etching.

  1. Incomplete penetrance and phenotypic variability of 6q16 deletions including SIM1.

    PubMed

    El Khattabi, Laïla; Guimiot, Fabien; Pipiras, Eva; Andrieux, Joris; Baumann, Clarisse; Bouquillon, Sonia; Delezoide, Anne-Lise; Delobel, Bruno; Demurger, Florence; Dessuant, Hélène; Drunat, Séverine; Dubourg, Christelle; Dupont, Céline; Faivre, Laurence; Holder-Espinasse, Muriel; Jaillard, Sylvie; Journel, Hubert; Lyonnet, Stanislas; Malan, Valérie; Masurel, Alice; Marle, Nathalie; Missirian, Chantal; Moerman, Alexandre; Moncla, Anne; Odent, Sylvie; Palumbo, Orazio; Palumbo, Pietro; Ravel, Aimé; Romana, Serge; Tabet, Anne-Claude; Valduga, Mylène; Vermelle, Marie; Carella, Massimo; Dupont, Jean-Michel; Verloes, Alain; Benzacken, Brigitte; Delahaye, Andrée

    2015-08-01

    6q16 deletions have been described in patients with a Prader-Willi-like (PWS-like) phenotype. Recent studies have shown that certain rare single-minded 1 (SIM1) loss-of-function variants were associated with a high intra-familial risk for obesity with or without features of PWS-like syndrome. Although SIM1 seems to have a key role in the phenotype of patients carrying 6q16 deletions, some data support a contribution of other genes, such as GRIK2, to explain associated behavioural problems. We describe 15 new patients in whom de novo 6q16 deletions were characterised by comparative genomic hybridisation or single-nucleotide polymorphism (SNP) array analysis, including the first patient with fetopathological data. This fetus showed dysmorphic facial features, cerebellar and cerebral migration defects with neuronal heterotopias, and fusion of brain nuclei. The size of the deletion in the 14 living patients ranged from 1.73 to 7.84 Mb, and the fetus had the largest deletion (14 Mb). Genotype-phenotype correlations confirmed the major role for SIM1 haploinsufficiency in obesity and the PWS-like phenotype. Nevertheless, only 8 of 13 patients with SIM1 deletion exhibited obesity, in agreement with incomplete penetrance of SIM1 haploinsufficiency. This study in the largest series reported to date confirms that the PWS-like phenotype is strongly linked to 6q16.2q16.3 deletions and varies considerably in its clinical expression. The possible involvement of other genes in the 6q16.2q16.3-deletion phenotype is discussed.

  2. Development of the IBSAL-SimMOpt Method for the Optimization of Quality in a Corn Stover Supply Chain

    DOE PAGES

    Chavez, Hernan; Castillo-Villar, Krystel; Webb, Erin

    2017-08-01

    Variability on the physical characteristics of feedstock has a relevant effect on the reactor’s reliability and operating cost. Most of the models developed to optimize biomass supply chains have failed to quantify the effect of biomass quality and preprocessing operations required to meet biomass specifications on overall cost and performance. The Integrated Biomass Supply Analysis and Logistics (IBSAL) model estimates the harvesting, collection, transportation, and storage cost while considering the stochastic behavior of the field-to-biorefinery supply chain. This paper proposes an IBSAL-SimMOpt (Simulation-based Multi-Objective Optimization) method for optimizing the biomass quality and costs associated with the efforts needed to meetmore » conversion technology specifications. The method is developed in two phases. For the first phase, a SimMOpt tool that interacts with the extended IBSAL is developed. For the second phase, the baseline IBSAL model is extended so that the cost for meeting and/or penalization for failing in meeting specifications are considered. The IBSAL-SimMOpt method is designed to optimize quality characteristics of biomass, cost related to activities intended to improve the quality of feedstock, and the penalization cost. A case study based on 1916 farms in Ontario, Canada is considered for testing the proposed method. Analysis of the results demonstrates that this method is able to find a high-quality set of non-dominated solutions.« less

  3. Development of the IBSAL-SimMOpt Method for the Optimization of Quality in a Corn Stover Supply Chain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chavez, Hernan; Castillo-Villar, Krystel; Webb, Erin

    Variability on the physical characteristics of feedstock has a relevant effect on the reactor’s reliability and operating cost. Most of the models developed to optimize biomass supply chains have failed to quantify the effect of biomass quality and preprocessing operations required to meet biomass specifications on overall cost and performance. The Integrated Biomass Supply Analysis and Logistics (IBSAL) model estimates the harvesting, collection, transportation, and storage cost while considering the stochastic behavior of the field-to-biorefinery supply chain. This paper proposes an IBSAL-SimMOpt (Simulation-based Multi-Objective Optimization) method for optimizing the biomass quality and costs associated with the efforts needed to meetmore » conversion technology specifications. The method is developed in two phases. For the first phase, a SimMOpt tool that interacts with the extended IBSAL is developed. For the second phase, the baseline IBSAL model is extended so that the cost for meeting and/or penalization for failing in meeting specifications are considered. The IBSAL-SimMOpt method is designed to optimize quality characteristics of biomass, cost related to activities intended to improve the quality of feedstock, and the penalization cost. A case study based on 1916 farms in Ontario, Canada is considered for testing the proposed method. Analysis of the results demonstrates that this method is able to find a high-quality set of non-dominated solutions.« less

  4. Social network analysis of public health programs to measure partnership.

    PubMed

    Schoen, Martin W; Moreland-Russell, Sarah; Prewitt, Kim; Carothers, Bobbi J

    2014-12-01

    In order to prevent chronic diseases, community-based programs are encouraged to take an ecological approach to public health promotion and involve many diverse partners. Little is known about measuring partnership in implementing public health strategies. We collected data from 23 Missouri communities in early 2012 that received funding from three separate programs to prevent obesity and/or reduce tobacco use. While all of these funding programs encourage partnership, only the Social Innovation for Missouri (SIM) program included a focus on building community capacity and enhancing collaboration. Social network analysis techniques were used to understand contact and collaboration networks in community organizations. Measurements of average degree, density, degree centralization, and betweenness centralization were calculated for each network. Because of the various sizes of the networks, we conducted comparative analyses with and without adjustment for network size. SIM programs had increased measurements of average degree for partner collaboration and larger networks. When controlling for network size, SIM groups had higher measures of network density and lower measures of degree centralization and betweenness centralization. SIM collaboration networks were more dense and less centralized, indicating increased partnership. The methods described in this paper can be used to compare partnership in community networks of various sizes. Further research is necessary to define causal mechanisms of partnership development and their relationship to public health outcomes. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Advancements in the application of NanoSIMS and Raman microspectroscopy to investigate the activity of microbial cells in soils

    DOE PAGES

    Eichorst, Stephanie A.; Strasser, Florian; Woyke, Tanja; ...

    2015-08-31

    The combined approach of incubating environmental samples with stable isotope-labeled substrates followed by single-cell analyses through high-resolution secondary ion mass spectrometry (NanoSIMS) or Raman microspectroscopy provides insights into the in situ function of microorganisms. This approach has found limited application in soils presumably due to the dispersal of microbial cells in a large background of particles. We developed a pipeline for the efficient preparation of cell extracts from soils for subsequent single-cell methods by combining cell detachment with separation of cells and soil particles followed by cell concentration. The procedure was evaluated by examining its influence on cell recoveries andmore » microbial community composition across two soils. This approach generated a cell fraction with considerably reduced soil particle load and of sufficient small size to allow single-cell analysis by NanoSIMS, as shown when detecting active N2-fixing and cellulose-responsive microorganisms via 15N2 and 13C-UL-cellulose incubations, respectively. The same procedure was also applicable for Raman microspectroscopic analyses of soil microorganisms, assessed via microcosm incubations with a 13C-labeled carbon source and deuterium oxide (D2O, a general activity marker). Lastly, the described sample preparation procedure enables single-cell analysis of soil microorganisms using NanoSIMS and Raman microspectroscopy, but should also facilitate single-cell sorting and sequencing.« less

  6. Force supplementary comparison at SIM (SIM.M.F-S5), compression testing machines calibration, up to 200 kN

    NASA Astrophysics Data System (ADS)

    Cárdenas Moctezuma, A.; Torres Guzmán, J. C.

    2016-01-01

    CENAM, through the Force and Pressure Division, organized a comparison on testing machines calibration, in compression mode. The participating laboratories were SIM National Institutes of Metrology from Colombia, Peru and Costa Rica, where CENAM, Mexico was the pilot and reference laboratory. The results obtained by the laboratories are presented in this paper as well as the analysis of compatibility. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. Secondary ion mass spectrometry and Raman spectroscopy for tissue engineering applications

    PubMed Central

    Ilin, Yelena; Kraft, Mary L.

    2014-01-01

    Identifying the matrix properties that permit directing stem cell fate is critical for expanding desired cell lineages ex vivo for disease treatment. Such efforts require knowledge of matrix surface chemistry and the cell responses they elicit. Recent progress in analyzing biomaterial composition and identifying cell phenotype with two label-free chemical imaging techniques, TOF-SIMS and Raman spectroscopy are presented. TOF-SIMS is becoming indispensable for the surface characterization of biomaterial scaffolds. Developments in TOF-SIMS data analysis enable correlating surface chemistry with biological response. Advances in the interpretation of Raman spectra permit identifying the fate decisions of individual, living cells with location specificity. Here we highlight this progress and discuss further improvements that would facilitate efforts to develop artificial scaffolds for tissue regeneration. PMID:25462628

  8. Analysis of TOF-SIMS spectra from fullerene compounds

    NASA Astrophysics Data System (ADS)

    Kato, N.; Yamashita, Y.; Iida, S.; Sanada, N.; Kudo, M.

    2008-12-01

    We analyzed TOF-SIMS spectra obtained from three different size of fullerenes (C 60, C 70 and C 84) by using Ga +, Au + and Au 3+ primary ion beams and investigated the fragmentation patterns, the enhancement of secondary ion yields and the restraint of fragmentation by using cluster primary ion beams compared with monoatomic primary ion beams. In the TOS-SIMS spectra from C 70 and C 84, it was found that a fragment ion, identified as C 60+ ( m/ z = 720), showed a relatively high intensity compared with that of other fragment ions related to C 2 depletion. It was also found that the Au 3+ bombardment caused intensity enhancement of intact molecules (C 60+, C 70+ and C 84+) and restrained the fragmentation due to C 2 depletion.

  9. Spatial and temporal localization during embryonic and fetal human development of the transcription factor SIM2 in brain regions altered in Down syndrome.

    PubMed

    Rachidi, Mohammed; Lopes, Carmela; Charron, Giselle; Delezoide, Anne-Lise; Paly, Evelyne; Bloch, Bernard; Delabar, Jean-Maurice

    2005-08-01

    Human SIM2 is the ortholog of Drosophila single-minded (sim), a master regulator of neurogenesis and transcriptional factor controlling midline cell fate determination. We previously localized SIM2 in a chromosome 21 critical region for Down syndrome (DS). Here, we studied SIM2 gene using a new approach to provide insights in understanding of its potential role in human development. For the first time, we showed SIM2 spatial and temporal expression pattern during human central nervous system (CNS) development, from embryonic to fetal stages. Additional investigations were performed using a new optic microscopy technology to compare signal intensity and cell density [M. Rachidi, C. Lopes, S. Gassanova, P.M. Sinet, M. Vekemans, T. Attie, A.L. Delezoide, J.M. Delabar, Regional and cellular specificity of the expression of TPRD, the tetratricopeptide Down syndrome gene, during human embryonic development, Mech. Dev. 93 (2000) 189--193]. In embryonic stages, SIM2 was identified predominantly in restricted regions of CNS, in ventral part of D1/D2 diencephalic neuroepithelium, along the neural tube and in a few cell subsets of dorsal root ganglia. In fetal stages, SIM2 showed differential expression in pyramidal and granular cell layers of hippocampal formation, in cortical cells and in cerebellar external granular and Purkinje cell layers. SIM2 expression in embryonic and fetal brain could suggest a potential role in human CNS development, in agreement with Drosophila and mouse Sim mutant phenotypes and with the conservation of the Sim function in CNS development from Drosophila to Human. SIM2 expression in human fetal brain regions, which correspond to key structures for cognitive processes, correlates well with the behavioral phenotypes of Drosophila Sim mutants and transgenic mice overexpressing Sim2. In addition, SIM2-expressing brain regions correspond to the altered structures in DS patients. All together, these findings suggest a potential role of SIM2 in CNS development and indicate that SIM2 overexpression could participate to the pathogenesis of mental retardation in Down syndrome patients.

  10. Applications of time-of-flight secondary ion mass spectrometry (TOF-SIMS) and X-ray photoelectron spectroscopy (XPS) to study interactions of genetically engineered proteins with noble metal films

    NASA Astrophysics Data System (ADS)

    Suzuki, Noriaki

    Genetically engineered proteins for inorganics (GEPIs) belong to a new class of polypeptides that are designed to have specific affinities to inorganic materials. A "gold binding protein (GBP)" was chosen as a model protein for GEPIs to study the molecular origins of binding specificity to gold using Time-of-flight secondary ion mass spectrometry (TOF-SIMS) and X-ray photoelectron spectroscopy (XPS). TOF-SIMS, a surface-sensitive analytical instrument with extremely high mass resolutions, provides information on specific amino acid-surface interactions. We used "principal component analysis (PCA)" to analyze the data. We also introduced a new multivariate technique, "hierarchical cluster analysis (HCA)" to organize the data into meaningful structures by measuring a degree of "similarity" and "dissimilarity" of the data. This report discusses a combined use of PCA and HCA to elucidate the binding specificity of GBP to Au. Based on the knowledge gained from TOF-SIMS measurements, we further investigated the nature of the interaction between selected amino acids and noble metal surfaces by using X-ray photoelectron spectroscopy (XPS). We developed a unique capability to introduce water vapor during the adsorption of a single amino acid and applied this method to study the intrinsic nature of sidechain/Au interactions. To further apply this unique research protocol, we characterized another type of GEPI, "quartz binding protein (QBP)," to identify the possible binding sites. This thesis research aims to provide experimental protocols for analyzing short peptide-substrate interface from complex spectroscopic data by using multivariate analysis techniques.

  11. Structured illumination microscopy as a diagnostic tool for nephrotic disease

    NASA Astrophysics Data System (ADS)

    Nylk, Jonathan; Pullman, James M.; Campbell, Elaine C.; Gunn-Moore, Frank J.; Prystowsky, Michael B.; Dholakia, Kishan

    2017-02-01

    Nephrotic disease is a group of debilitating and sometimes lethal diseases affecting kidney function, specifically the loss of ability to retain vital proteins in the blood while smaller molecules are removed through filtration into the urine. Treatment routes are often dictated by microscopic analysis of kidney biopsies. Podocytes within the glomeruli of the kidney have many interdigitating projections (foot processes), which form the main filtration system. Nephrotic disease is characterised by the loss of this tightly interdigitating substructure and its observation by electron microscopy (EM) is necessitated as these structures are typically 250 500nm wide, with 40nm spacing. Diagnosis by EM is both expensive and time consuming; it can take up to one week to complete the preparation, imaging, and analysis of a single sample. We propose structured illumination microscopy (SIM) as an alternative, optical diagnostic tool. Our results show that SIM can resolve the structure of fluorescent probes tagged to podocin, a protein localised to the periphery of the podocyte foot processes. Three-dimensional podocin maps were acquired in healthy tissue and tissue from patients diagnosed with two different nephrotic disease states; minimal change disease and membranous nephropathy. These structures correlated well with EM images of the same structure. Preparation, imaging, and analysis could be achieved in several hours. Additionally, the volumetric information of the SIM images revealed morphological changes in disease states not observed by EM. This evidence supports the use of SIM as a diagnostic tool for nephrotic disease and can potentially reduce the time and cost per diagnosis.

  12. Hyperspectral Data Processing and Mapping of Soil Parameters: Preliminary Data from Tuscany (Italy)

    NASA Astrophysics Data System (ADS)

    Garfagnoli, F.; Moretti, S.; Catani, F.; Innocenti, L.; Chiarantini, L.

    2010-12-01

    Hyperspectral imaging has become a very powerful remote sensing tool for its capability of performing chemical and physical analysis of the observed areas. The objective of this study is to retrieve and characterize clay mineral content of the cultivated layer of soils, from both airborne hyperspectral and field spectrometry surveys in the 400-2500 nm spectral range. Correlation analysis is used to examine the possibility to predict the selected property using high-resolution reflectance spectra and images. The study area is located in the Mugello basin, about 30 km north of Firenze (Tuscany, Italy). Agriculturally suitable terrains are assigned mainly to annual crops, marginally to olive groves, vineyards and orchards. Soils mostly belong to Regosols and Cambisols orders. About 80 topsoil samples scattered all over the area were collected simultaneously with the flight of SIM.GA hyperspectral camera from Selex Galileo. The quantitative determination of clay minerals content in soil samples was performed by means of XRD and Rietveld refinement. An ASD FieldSpec spectroradiometer was used to obtain reflectance spectra from dried, crushed and sieved samples under controlled laboratory conditions. Different chemometric techniques (multiple linear regression, vertex component analysis, partial least squares regression and band depth analysis) were preliminarily tested to correlate mineralogical records with reflectance data. A one component partial least squares regression model yielded a preliminary R2 value of 0.65. A similar result was achieved by plotting the absorption peak depth at 2210 versus total clay mineral content (band-depth analysis). A complete hyperspectral geocoded reflectance dataset was collected using SIM.GA hyperspectral image sensor from Selex-Galileo, mounted on board of the University of Firenze ultra light aircraft. The approximate pixel resolution was 0.6 m (VNIR) and 1.2 m (SWIR). Airborne SIM.GA row data were firstly transformed into at-sensor radiance values, where calibration coefficients and parameters from laboratory measurements are applied to non-georeferred VNIR/SWIR DN values. Then, geocoded products are retrieved for each flight line by using a procedure developed in IDL Language and PARGE (PARametric Geocoding) software. When all compensation parameters are applied to hyperspectral data or to the final thematic map, orthorectified, georeferred and coregistered VNIR to SWIR images or maps are available for GIS application and 3D view. Airborne imagery has to be corrected for the influence of the atmosphere, solar illumination, sensor viewing geometry and terrain geometry information, for the retrieval of inherent surface reflectance properties. Then, different geophysical parameters can be investigated and retrieved by means of inversion algorithms. The experimental fitting of laboratory data on mineral content is used for airborne data inversion, whose results are in agreement with laboratory records, demonstrating the possibility to use this methodology for digital mapping of soil properties.

  13. Laparoscopic virtual reality and box trainers: is one superior to the other?

    PubMed

    Munz, Y; Kumar, B D; Moorthy, K; Bann, S; Darzi, A

    2004-03-01

    Virtual reality (VR) simulators now have the potential to replace traditional methods of laparoscopic training. The aim of this study was to compare the VR simulator with the classical box trainer and determine whether one has advantages over the other. Twenty four novices were tested to determine their baseline laparoscopic skills and then randomized into the following three group: LapSim, box trainer, and no training (control). After 3 weekly training sessions lasting 30-min each, all subjects were reassessed. Assessment included motion analysis and error scores. Nonparametric tests were applied, and p < 0.05 was deemed significant. Both trained groups made significant improvements in all parameters measured ( p < 0.05). Compared to the controls, the box trainer group performed significantly better on most of the parameters, whereas the LapSim group performed significantly better on some parameters. There were no significant differences between the LapSim and box trainer groups. LapSim is effective in teaching skills that are transferable to a real laparoscopic task. However, there appear to be no substantial advantages of one system over the other.

  14. Assessing the learning curve for the acquisition of laparoscopic skills on a virtual reality simulator.

    PubMed

    Sherman, V; Feldman, L S; Stanbridge, D; Kazmi, R; Fried, G M

    2005-05-01

    The aim of this study was to develop summary metrics and assess the construct validity for a virtual reality laparoscopic simulator (LapSim) by comparing the learning curves of three groups with different levels of laparoscopic expertise. Three groups of subjects ('expert', 'junior', and 'naïve') underwent repeated trials on three LapSim tasks. Formulas were developed to calculate scores for efficiency ('time-error') and economy of 'motion' ('motion') using metrics generated by the software after each drill. Data (mean +/- SD) were evaluated by analysis of variance (ANOVA). Significance was set at p < 0.05. All three groups improved significantly from baseline to final for both 'time-error' and 'motion' scores. There were significant differences between groups in time error performances at baseline and final, due to higher scores in the 'expert' group. A significant difference in 'motion' scores was seen only at baseline. We have developed summary metrics for the LapSim that differentiate among levels of laparoscopic experience. This study also provides evidence of construct validity for the LapSim.

  15. Kaiser Permanente/Sandia National health care model. Phase I prototype final report. Part 1 - model overview

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edwards, D.; Yoshimura, A.; Butler, D.

    1996-11-01

    This report describes the results of a Cooperative Research and Development Agreement between Sandia National Laboratories and Kaiser Permanente Southern California to develop a prototype computer model of Kaiser Permanente`s health care delivery system. As a discrete event simulation, SimHCO models for each of 100,000 patients the progression of disease, individual resource usage, and patient choices in a competitive environment. SimHCO is implemented in the object-oriented programming language C++, stressing reusable knowledge and reusable software components. The versioned implementation of SimHCO showed that the object-oriented framework allows the program to grow in complexity in an incremental way. Furthermore, timing calculationsmore » showed that SimHCO runs in a reasonable time on typical workstations, and that a second phase model will scale proportionally and run within the system constraints of contemporary computer technology. This report is published as two documents: Model Overview and Domain Analysis. A separate Kaiser-proprietary report contains the Disease and Health Care Organization Selection Models.« less

  16. SIM Lite Astrometric Observatory progress report

    NASA Astrophysics Data System (ADS)

    Marr, James C., IV; Shao, Michael; Goullioud, Renaud

    2010-07-01

    The SIM Lite Astrometric Observatory (aka SIM Lite), a micro-arcsecond astrometry space mission, has been developed in response to NASA's indefinite deferral of the SIM PlanetQuest mission. The SIM Lite mission, while significantly more affordable than the SIM PlanetQuest mission concept, still addresses the full breadth of SIM science envisioned by two previous National Research Council (NRC) Astrophysics Decadal Surveys at the most stringent "Goal" level of astrometric measurement performance envisioned in those surveys. Over the past two years, the project has completed the conceptual design of the SIM Lite mission using only the completed SIM technology; published a 250 page book describing the science and mission design (available at the SIM website: http://sim.jpl.nasa.gov); been subject to an independent cost and technical readiness assessment by the Aerospace Corporation; and submitted a number of information responses to the NRC Astro2010 Decadal Survey. The project also conducted an exoplanet-finding capability double blind study that clearly demonstrated the ability of the mission to survey 60 to 100 nearby sun-like dwarf stars for terrestrial, habitable zone planets in complex planetary systems. Additionally, the project has continued Engineering Risk Reduction activities by building brassboard (form, fit & function to flight) version of key instrument elements and subjecting them to flight qualification environmental and performance testing. This paper summarizes the progress over the last two years and the current state of the SIM Lite project.

  17. [Rapid determination of 40 pesticide residues in fruits using gas chromatography-mass spectrometry coupled with analyte protectants to compensate for matrix effects].

    PubMed

    Xu, Xiuli; Zhao, Haixiang; Li, Li; Liu, Hanxia; Ren, Heling; Zhong, Weike

    2012-03-01

    A gas chromatography-mass spectrometry (GC-MS) method was developed for the determination of 40 pesticides in fruits. The effects of adding analyte protectants were evaluated for compensating matrix effects and the impacts on the quantitative results. A new combination of analyte protectants - Polyethylene Glycol 400 (PEG 400) and olive oil combination, which can be dissolved in acetone, was used for the quantitative analysis. The pesticides were extracted from fruit samples with acetonitrile and the extracts were cleaned up using micro-solid phase extraction. A GC-MS method in selective ion monitoring (SIM) mode coupled with large volume injection was finally developed. Using the newly developed analyte protectant combination of PEG 400 and olive oil, a good linearity was obtained in the range of 1 - 200 microg/L with coefficients better than 0.99, and the detection limits were between 0.1 - 3.0 microg/L. The mean recoveries of the pesticides were 75% - 119% with the relative standard deviation values less than 16.6% except for dimethoate. The performance of the analyte protectants was compared with matrix-matched standards calibration curves in terms of quantitative accuracy. The results showed that the method of adding analyte protectants can replace the matrix-matched standard calibration, and can also reduce the sample pretreatment. When the devel- oped method was used for the analysis of apple, peache, orange, banana, grape and other fruit samples, a good matrix compensation effect was achieved, and thus effectively reduced the bad effects of the water-soluble agents to the gas chromatographic column.

  18. SimPackJ/S: a web-oriented toolkit for discrete event simulation

    NASA Astrophysics Data System (ADS)

    Park, Minho; Fishwick, Paul A.

    2002-07-01

    SimPackJ/S is the JavaScript and Java version of SimPack, which means SimPackJ/S is a collection of JavaScript and Java libraries and executable programs for computer simulations. The main purpose of creating SimPackJ/S is that we allow existing SimPack users to expand simulation areas and provide future users with a freeware simulation toolkit to simulate and model a system in web environments. One of the goals for this paper is to introduce SimPackJ/S. The other goal is to propose translation rules for converting C to JavaScript and Java. Most parts demonstrate the translation rules with examples. In addition, we discuss a 3D dynamic system model and overview an approach to 3D dynamic systems using SimPackJ/S. We explain an interface between SimPackJ/S and the 3D language--Virtual Reality Modeling Language (VRML). This paper documents how to translate C to JavaScript and Java and how to utilize SimPackJ/S within a 3D web environment.

  19. ToF-SIMS imaging of molecular-level alteration mechanisms in Le Bonheur de vivre by Henri Matisse.

    PubMed

    Voras, Zachary E; deGhetaldi, Kristin; Wiggins, Marcie B; Buckley, Barbara; Baade, Brian; Mass, Jennifer L; Beebe, Thomas P

    2015-11-01

    Time-of-flight secondary ion mass spectrometry (ToF-SIMS) has recently been shown to be a valuable tool for cultural heritage studies, especially when used in conjunction with established analytical techniques in the field. The ability of ToF-SIMS to simultaneously image inorganic and organic species within a paint cross section at micrometer-level spatial resolution makes it a uniquely qualified analytical technique to aid in further understanding the processes of pigment and binder alteration, as well as pigment-binder interactions. In this study, ToF-SIMS was used to detect and image both molecular and elemental species related to CdS pigment and binding medium alteration on the painting Le Bonheur de vivre (1905-1906, The Barnes Foundation) by Henri Matisse. Three categories of inorganic and organic components were found throughout Le Bonheur de vivre and co-localized in cross-sectional samples using high spatial resolution ToF-SIMS analysis: (1) species relating to the preparation and photo-induced oxidation of CdS yellow pigments (2) varying amounts of long-chain fatty acids present in both the paint and primary ground layer and (3) specific amino acid fragments, possibly relating to the painting's complex restoration history. ToF-SIMS's ability to discern both organic and inorganic species via cross-sectional imaging was used to compare samples collected from Le Bonheur de vivre to artificially aged reference paints in an effort to gather mechanistic information relating to alteration processes that have been previously explored using μXANES, SR-μXRF, SEM-EDX, and SR-FTIR. The relatively high sensitivity offered by ToF-SIMS imaging coupled to the high spatial resolution allowed for the positive identification of degradation products (such as cadmium oxalate) in specific paint regions that have before been unobserved. The imaging of organic materials has provided an insight into the extent of destruction of the original binding medium, as well as identifying unexpected organic materials in specific paint layers.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Herrmann, A M; Ritz, K; Nunan, N

    Soils are structurally heterogeneous across a wide range of spatio-temporal scales. Consequently, external environmental conditions do not have a uniform effect throughout the soil, resulting in a large diversity of micro-habitats. It has been suggested that soil function can be studied without explicit consideration of such fine detail, but recent research has indicated that the micro-scale distribution of organisms may be of importance for a mechanistic understanding of many soil functions. Due to a lack of techniques with adequate sensitivity for data collection at appropriate scales, the question 'How important are various soil processes acting at different scales for ecologicalmore » function?' is challenging to answer. The nano-scale secondary ion mass spectrometer (NanoSIMS) represents the latest generation of ion microprobes which link high-resolution microscopy with isotopic analysis. The main advantage of NanoSIMS over other secondary ion mass spectrometers is the ability to operate at high mass resolution, whilst maintaining both excellent signal transmission and spatial resolution ({approx}50 nm). NanoSIMS has been used previously in studies focusing on presolar materials from meteorites, in material science, biology, geology and mineralogy. Recently, the potential of NanoSIMS as a new tool in the study of biophysical interfaces in soils has been demonstrated. This paper describes the principles of NanoSIMS and discusses the potential of this tool to contribute to the field of biogeochemistry and soil ecology. Practical considerations (sample size and preparation, simultaneous collection of isotopes, mass resolution, isobaric interference and quantification of the isotopes of interest) are discussed. Adequate sample preparation avoiding biases in the interpretation of NanoSIMS data due to artifacts and identification of regions-of interest are of most concerns in using NanoSIMS as a new tool in biogeochemistry and soil ecology. Finally, we review the areas of research most likely to benefit from the high resolving power attainable with this new approach.« less

  1. ToF-SIMS imaging of molecular-level alteration mechanisms in Le Bonheur de vivre by Henri Matisse

    NASA Astrophysics Data System (ADS)

    Voras, Zachary E.; deGhetaldi, Kristin; Wiggins, Marcie B.; Buckley, Barbara; Baade, Brian; Mass, Jennifer L.; Beebe, Thomas P.

    2015-11-01

    Time-of-flight secondary ion mass spectrometry (ToF-SIMS) has recently been shown to be a valuable tool for cultural heritage studies, especially when used in conjunction with established analytical techniques in the field. The ability of ToF-SIMS to simultaneously image inorganic and organic species within a paint cross section at micrometer-level spatial resolution makes it a uniquely qualified analytical technique to aid in further understanding the processes of pigment and binder alteration, as well as pigment-binder interactions. In this study, ToF-SIMS was used to detect and image both molecular and elemental species related to CdS pigment and binding medium alteration on the painting Le Bonheur de vivre (1905-1906, The Barnes Foundation) by Henri Matisse. Three categories of inorganic and organic components were found throughout Le Bonheur de vivre and co-localized in cross-sectional samples using high spatial resolution ToF-SIMS analysis: (1) species relating to the preparation and photo-induced oxidation of CdS yellow pigments (2) varying amounts of long-chain fatty acids present in both the paint and primary ground layer and (3) specific amino acid fragments, possibly relating to the painting's complex restoration history. ToF-SIMS's ability to discern both organic and inorganic species via cross-sectional imaging was used to compare samples collected from Le Bonheur de vivre to artificially aged reference paints in an effort to gather mechanistic information relating to alteration processes that have been previously explored using μXANES, SR-μXRF, SEM-EDX, and SR-FTIR. The relatively high sensitivity offered by ToF-SIMS imaging coupled to the high spatial resolution allowed for the positive identification of degradation products (such as cadmium oxalate) in specific paint regions that have before been unobserved. The imaging of organic materials has provided an insight into the extent of destruction of the original binding medium, as well as identifying unexpected organic materials in specific paint layers.

  2. Multi-Satellite Measurements and Model Predictions of Mesospheric and Upper Stratospheric Influences from the Very Large July 14-16, 2000, Solar Proton Event

    NASA Technical Reports Server (NTRS)

    Jackman, Charles H.; McPeters, Richard D.; Russell, James M.; Bevilacqua, Richard; Labow, Gordon J.; Fleming, Eric L.; Einaudi, Franco (Technical Monitor)

    2000-01-01

    A large solar flare with an associated coronal mass ejection occurred in mid-July and caused a very large solar proton event at the earth in the time period July 14-16, 2000. So far this is the largest solar storm of solar cycle 23. The solar proton fluxes were measured by instruments aboard the GOES-10 satellite and used in our proton energy deposition model to help quantify the energy input to the middle atmosphere during this large solar event. Using this computed energy deposition in the GSFC 2D atmospheric model resulted in a prediction of $>$ 20\\% increases in HO$-(x)$ (H, OH, HO$-(2)$) and $>$ 100\\% increases in NO$-(x)$ (N, NO, NO$-(2)$) constituents in the mesosphere and upper stratosphere at polar latitudes ($>$ 60 degrees geomagnetic). Both the HO$-(x)$ and NO$_fx)$ increases impacted ozone. Large atmospheric impacts have been measured with the NOAA 14 SBUV/2 instrument (0$_(3)$), the UARS HALOE instrument (NO, NO$-(2)$, 0$-(3)$), and the POAM III instrument (0$_{3}$, NO$-(2)$). Preliminary analysis indicates that measured (SBUV/2) and modelled 0$_{3}$ decreases from this solar event are generally in agreement in the Northern Hemisphere. Short-term ozone changes (during the event) indicate $\\sim$ 15% reduction at 2 hPa ($\\sim$ 45 km) up to $\\sim$ 40% reduction at 0.5 hPa ($\\sim$ 55 km). A longer-term ozone depletion of $\\sim$ 5% is indicated between 4 and 2 hPa ($\\sim$ 40-45 km). The middle atmospheric changes caused by this solar event were very large and occurred fairly quickly ($\\sim$ 1-2 days). Such a significant natural perturbation provides a good test of our understanding of the middle atmosphere. The measured and modelled impacts of this solar event will be compared and discussed in this paper.

  3. Multielement analysis of interplanetary dust particles using TOF-SIMS

    NASA Technical Reports Server (NTRS)

    Stephan, T.; Kloeck, W.; Jessberger, E. K.; Rulle, H.; Zehnpfenning, J.

    1993-01-01

    Sections of three stratospheric particles (U2015G1, W7029*A27, and L2005P9) were analyzed with TOF-SIMS (Time Of Flight-Secondary Ion Mass Spectrometry) continuing our efforts to investigate the element distribution in interplanetary dust particles (IDP's) with high lateral resolution (approximately 0.2 micron), to examine possible atmospheric contamination effects, and to further explore the abilities of this technique for element analysis of small samples. The samples, previously investigated with SXRF (synchrotron X-ray fluorescence analysis), are highly enriched in Br (Br/Fe: 59 x CI, 9.2 x CI, and 116 x CI, respectively). U2015G1 is the IDP with the by far highest Zn/Fe-ratio (81 x CI) ever reported in chondritic particles.

  4. Impact of rheology on probabilistic forecasts of sea ice trajectories: application for search and rescue operations in the Arctic

    NASA Astrophysics Data System (ADS)

    Rabatel, Matthias; Rampal, Pierre; Carrassi, Alberto; Bertino, Laurent; Jones, Christopher K. R. T.

    2018-03-01

    We present a sensitivity analysis and discuss the probabilistic forecast capabilities of the novel sea ice model neXtSIM used in hindcast mode. The study pertains to the response of the model to the uncertainty on winds using probabilistic forecasts of ice trajectories. neXtSIM is a continuous Lagrangian numerical model that uses an elasto-brittle rheology to simulate the ice response to external forces. The sensitivity analysis is based on a Monte Carlo sampling of 12 members. The response of the model to the uncertainties is evaluated in terms of simulated ice drift distances from their initial positions, and from the mean position of the ensemble, over the mid-term forecast horizon of 10 days. The simulated ice drift is decomposed into advective and diffusive parts that are characterised separately both spatially and temporally and compared to what is obtained with a free-drift model, that is, when the ice rheology does not play any role in the modelled physics of the ice. The seasonal variability of the model sensitivity is presented and shows the role of the ice compactness and rheology in the ice drift response at both local and regional scales in the Arctic. Indeed, the ice drift simulated by neXtSIM in summer is close to the one obtained with the free-drift model, while the more compact and solid ice pack shows a significantly different mechanical and drift behaviour in winter. For the winter period analysed in this study, we also show that, in contrast to the free-drift model, neXtSIM reproduces the sea ice Lagrangian diffusion regimes as found from observed trajectories. The forecast capability of neXtSIM is also evaluated using a large set of real buoy's trajectories and compared to the capability of the free-drift model. We found that neXtSIM performs significantly better in simulating sea ice drift, both in terms of forecast error and as a tool to assist search and rescue operations, although the sources of uncertainties assumed for the present experiment are not sufficient for complete coverage of the observed IABP positions.

  5. Streptococcus iniae M-Like Protein Contributes to Virulence in Fish and Is a Target for Live Attenuated Vaccine Development

    PubMed Central

    Locke, Jeffrey B.; Aziz, Ramy K.; Vicknair, Mike R.; Nizet, Victor; Buchanan, John T.

    2008-01-01

    Background Streptococcus iniae is a significant pathogen in finfish aquaculture, though knowledge of virulence determinants is lacking. Through pyrosequencing of the S. iniae genome we have identified two gene homologues to classical surface-anchored streptococcal virulence factors: M-like protein (simA) and C5a peptidase (scpI). Methodology/Principal Findings S. iniae possesses a Mga-like locus containing simA and a divergently transcribed putative mga-like regulatory gene, mgx. In contrast to the Mga locus of group A Streptococcus (GAS, S. pyogenes), scpI is located distally in the chromosome. Comparative sequence analysis of the Mgx locus revealed only one significant variant, a strain with an insertion frameshift mutation in simA and a deletion mutation in a region downstream of mgx, generating an ORF which may encode a second putative mga-like gene, mgx2. Allelic exchange mutagenesis of simA and scpI was employed to investigate the potential role of these genes in S. iniae virulence. Our hybrid striped bass (HSB) and zebrafish models of infection revealed that M-like protein contributes significantly to S. iniae pathogenesis whereas C5a peptidase-like protein does not. Further, in vitro cell-based analyses indicate that SiMA, like other M family proteins, contributes to cellular adherence and invasion and provides resistance to phagocytic killing. Attenuation in our virulence models was also observed in the S. iniae isolate possessing a natural simA mutation. Vaccination of HSB with the ΔsimA mutant provided 100% protection against subsequent challenge with a lethal dose of wild-type (WT) S. iniae after 1,400 degree days, and shows promise as a target for live attenuated vaccine development. Conclusions/Significance Analysis of M-like protein and C5a peptidase through allelic replacement revealed that M-like protein plays a significant role in S. iniae virulence, and the Mga-like locus, which may regulate expression of this gene, has an unusual arrangement. The M-like protein mutant created in this research holds promise as live-attenuated vaccine. PMID:18665241

  6. SimArray: a user-friendly and user-configurable microarray design tool

    PubMed Central

    Auburn, Richard P; Russell, Roslin R; Fischer, Bettina; Meadows, Lisa A; Sevillano Matilla, Santiago; Russell, Steven

    2006-01-01

    Background Microarrays were first developed to assess gene expression but are now also used to map protein-binding sites and to assess allelic variation between individuals. Regardless of the intended application, efficient production and appropriate array design are key determinants of experimental success. Inefficient production can make larger-scale studies prohibitively expensive, whereas poor array design makes normalisation and data analysis problematic. Results We have developed a user-friendly tool, SimArray, which generates a randomised spot layout, computes a maximum meta-grid area, and estimates the print time, in response to user-specified design decisions. Selected parameters include: the number of probes to be printed; the microtitre plate format; the printing pin configuration, and the achievable spot density. SimArray is compatible with all current robotic spotters that employ 96-, 384- or 1536-well microtitre plates, and can be configured to reflect most production environments. Print time and maximum meta-grid area estimates facilitate evaluation of each array design for its suitability. Randomisation of the spot layout facilitates correction of systematic biases by normalisation. Conclusion SimArray is intended to help both established researchers and those new to the microarray field to develop microarray designs with randomised spot layouts that are compatible with their specific production environment. SimArray is an open-source program and is available from . PMID:16509966

  7. Comparative Analyses of Data Independent Acquisition Mass Spectrometric Approaches: DIA, WiSIM‐DIA, and Untargeted DIA

    PubMed Central

    Ho, Jenny T. C.; Smit, August B.; Li, Ka Wan

    2018-01-01

    Abstract Data‐independent acquisition (DIA) is an emerging technology for quantitative proteomics. Current DIA focusses on the identification and quantitation of fragment ions that are generated from multiple peptides contained in the same selection window of several to tens of m/z. An alternative approach is WiSIM‐DIA, which combines conventional DIA with wide‐SIM (wide selected‐ion monitoring) windows to partition the precursor m/z space to produce high‐quality precursor ion chromatograms. However, WiSIM‐DIA has been underexplored; it remains unclear if it is a viable alternative to DIA. We demonstrate that WiSIM‐DIA quantified more than 24 000 unique peptides over five orders of magnitude in a single 2 h analysis of a neuronal synapse‐enriched fraction, compared to 31 000 in DIA. There is a strong correlation between abundance values of peptides quantified in both the DIA and WiSIM‐DIA datasets. Interestingly, the S/N ratio of these peptides is not correlated. We further show that peptide identification directly from DIA spectra identified >2000 proteins, which included unique peptides not found in spectral libraries generated by DDA. PMID:29134766

  8. Automated Discovery of Simulation Between Programs

    DTIC Science & Technology

    2014-10-18

    relation. These relations enable the refinement-step of SimAbs. We have implemented SimAbs using UFO framework and Z3 SMT-solver and applied it to...step of SimAbs. We implemented SimAbs and AE-VAL on the top of the UFO framework [1, 15] and an SMT-solver Z3 [8], respectively. We have evaluated SimAbs...ut 6 Evaluation We have implemented SimAbs in the UFO framework, and evaluated it on the Software Verification Competition (SVCOMP’14) benchmarks and

  9. The use of secondary ion mass spectrometry in forensic analyses of ultra-small samples

    NASA Astrophysics Data System (ADS)

    Cliff, John

    2010-05-01

    It is becoming increasingly important in forensic science to perform chemical and isotopic analyses on very small sample sizes. Moreover, in some instances the signature of interest may be incorporated in a vast background making analyses impossible by bulk methods. Recent advances in instrumentation make secondary ion mass spectrometry (SIMS) a powerful tool to apply to these problems. As an introduction, we present three types of forensic analyses in which SIMS may be useful. The causal organism of anthrax (Bacillus anthracis) chelates Ca and other metals during spore formation. Thus, the spores contain a trace element signature related to the growth medium that produced the organisms. Although other techniques have been shown to be useful in analyzing these signatures, the sample size requirements are generally relatively large. We have shown that time of flight SIMS (TOF-SIMS) combined with multivariate analysis, can clearly separate Bacillus sp. cultures prepared in different growth media using analytical spot sizes containing approximately one nanogram of spores. An important emerging field in forensic analysis is that of provenance of fecal pollution. The strategy of choice for these analyses-developing host-specific nucleic acid probes-has met with considerable difficulty due to lack of specificity of the probes. One potentially fruitful strategy is to combine in situ nucleic acid probing with high precision isotopic analyses. Bulk analyses of human and bovine fecal bacteria, for example, indicate a relative difference in d13C content of about 4 per mil. We have shown that sample sizes of several nanograms can be analyzed with the IMS 1280 with precisions capable of separating two per mil differences in d13C. The NanoSIMS 50 is capable of much better spatial resolution than the IMS 1280, albeit at a cost of analytical precision. Nevertheless we have documented precision capable of separating five per mil differences in d13C using analytical spots containing less than 300 picograms of bacteria. Perhaps the most successful application of SIMS for forensic purposes to date is in the field of nuclear forensics. An example that has been used by laboratories associated with the International Atomic Energy Agency is the examination of environmental samples for enriched uranium particles indicative of clandestine weapons production activities.. The analytical challenge in these types of measurements is to search complex environmental matrices for U-bearing particles which must then be analyzed for 234U, 235U, and 236U content with high precision and accuracy. Older-generation SIMS instruments were hampered by small geometries that made resolution of significant interferences problematic. In addition, automated particle search software was proprietary and difficult to obtain. With the development of new search software, the IMS 1280 is capable of searching a sample in a matter of hours, flagging U-bearing particles for later analyses, and providing a rough 235U content. Particles of interest can be revisited for high precision analyses, and all U-isotopes can be measured simultaneously in multicollector mode, dramatically improving analysis time and internal precision. Further, the large geometry of the instrument allows complete resolution of isobaric interferences that have traditionally limited SIMS analyses of difficult samples. Examples of analyses of micron-sized standard particles indicate that estimates of 235U enrichment can be obtained with an external relative precision of 0.1% and 234U and 236U contents can be obtained with a relative precision of less than 1%. Analyses of 'real' samples show a dramatic improvement in the data quality obtained compared with small-geometry SIMS instruments making SIMS the method of choice for these high-profile samples when accurate, precise, and rapid results are required.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peterson, John Russell

    This grant funded the development and dissemination of the Photon Simulator (PhoSim) for the purpose of studying dark energy at high precision with the upcoming Large Synoptic Survey Telescope (LSST) astronomical survey. The work was in collaboration with the LSST Dark Energy Science Collaboration (DESC). Several detailed physics improvements were made in the optics, atmosphere, and sensor, a number of validation studies were performed, and a significant number of usability features were implemented. Future work in DESC will use PhoSim as the image simulation tool for data challenges used by the analysis groups.

  11. Characterization of Meteorites by Focused Ion Beam Sectioning: Recent Applications to CAIs and Primitive Meteorite Matrices

    NASA Technical Reports Server (NTRS)

    Christoffersen, Roy; Keller, Lindsay P.; Han, Jangmi; Rahman, Zia; Berger, Eve L.

    2015-01-01

    Focused ion beam (FIB) sectioning has revolutionized preparation of meteorite samples for characterization by analytical transmission electron microscopy (TEM) and other techniques. Although FIB is not "non-destructive" in the purest sense, each extracted section amounts to no more than nanograms (approximately 500 cubic microns) removed intact from locations precisely controlled by SEM imaging and analysis. Physical alteration of surrounding material by ion damage, fracture or sputter contamination effects is localized to within a few micrometers around the lift-out point. This leaves adjacent material intact for coordinate geochemical analysis by SIMS, microdrill extraction/TIMS and other techniques. After lift out, FIB sections can be quantitatively analyzed by electron microprobe prior to final thinning, synchrotron x-ray techniques, and by the full range of state-of-the-art analytical field-emission scanning transmission electron microscope (FE-STEM) techniques once thinning is complete. Multiple meteorite studies supported by FIB/FE-STEM are currently underway at NASA-JSC, including coordinated analysis of refractory phase assemblages in CAIs and fine-grained matrices in carbonaceous chondrites. FIB sectioning of CAIs has uncovered epitaxial and other overgrowth relations between corundum-hibonite-spinel consistent with hibonite preceding corundum and/or spinel in non-equilibrium condensation sequences at combinations of higher gas pressures, dust-gas enrichments or significant nebular transport. For all of these cases, the ability of FIB to allow for coordination with spatially-associated isotopic data by SIMS provides immense value for constraining the formation scenarios of the particular CAI assemblage. For carbonaceous chondrites matrix material, FIB has allowed us to obtain intact continuous sections of the immediate outer surface of Murchison (CM2) after it has been experimentally ion processed to simulate solar wind space weathering. The surface amorphization and loss of OH produced by the irradiation provides important clues regarding space weathering on primitive asteroids such as the OSIRIS-Rex target 101955 Bennu.

  12. Sim1 haploinsufficiency impairs melanocortin-mediated anorexia and activation of paraventricular nucleus neurons.

    PubMed

    Kublaoui, Bassil M; Holder, J Lloyd; Gemelli, Terry; Zinn, Andrew R

    2006-10-01

    Single-minded 1 (SIM1) is one of only six genes implicated in human monogenic obesity. Haploinsufficiency of this hypothalamic transcription factor is associated with hyperphagic obesity and increased linear growth in both humans and mice. Additionally, Sim1 heterozygous mice show enhanced hyperphagia and obesity in response to a high-fat diet. Thus the phenotype of Sim1 haploinsufficiency is similar to that of agouti yellow (Ay), and melanocortin 4 receptor (Mc4r) knockout mice, both of which are defective in hypothalamic melanocortin signaling. Sim1 and Mc4r are both expressed in the paraventricular nucleus (PVN). Here we report that Sim1 heterozygous mice, which have normal energy expenditure, are hyperphagic despite having elevated hypothalamic proopiomelanocortin (Pomc) expression. In response to the melanocortin agonist melanotan-2 (MTII) they exhibit a blunted suppression of feeding yet increase their energy expenditure normally. They also fail to activate PVN neurons in response to the drug at a dose that induces robust c-Fos expression in a subset of Sim1 PVN neurons in wild-type mice. The resistance to melanocortin signaling in Sim1 heterozygotes is not due to a reduced number of Sim1 neurons in the PVN. Hypothalamic Sim1 gene expression is induced by leptin and MTII treatment. Our results demonstrate that Sim1 heterozygotes are resistant to hypothalamic melanocortin signaling and suggest that Sim1-expressing PVN neurons regulate feeding, but not energy expenditure, in response to melanocortin signaling.

  13. Structures of the TetR-like simocyclinone efflux pump repressor, SimR, and the mechanism of ligand-mediated derepression.

    PubMed

    Le, Tung B K; Stevenson, Clare E M; Fiedler, Hans-Peter; Maxwell, Anthony; Lawson, David M; Buttner, Mark J

    2011-04-22

    Simocyclinone D8 (SD8), a potent DNA gyrase inhibitor made by Streptomyces antibioticus, is exported from the producing organism by the SimX efflux pump. The expression of simX is under the control of SimR, a member of the TetR family of transcriptional regulators. SimR represses simX transcription by binding to operators in the intergenic region between simR and simX. Previously, we have shown that the mature antibiotic SD8 or its biosynthetic intermediate, simocyclinone C4, can dissociate SimR from its operators, leading to derepression of simX and export of SD8 from the cell. This provides a mechanism that couples the biosynthesis of the antibiotic to its export. Here, we report the crystal structures of SimR alone and in complex with either SD8 or simocyclinone C4. The ligand-binding pocket is unusual compared to those of other characterized TetR-family transcriptional regulators: the structures show an extensive ligand-binding pocket spanning both monomers in the functional dimeric unit, with the aminocoumarin moiety of SD8 buried in the protein core, while the angucyclic polyketide moiety is partially exposed to bulk solvent. Through comparisons of the structures, we postulate a derepression mechanism for SimR that invokes rigid-body motions of the subunits relative to one another, coupled with a putative locking mechanism to restrict further conformational change. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. The impact of detergents on the tissue decellularization process: A ToF-SIMS study.

    PubMed

    White, Lisa J; Taylor, Adam J; Faulk, Denver M; Keane, Timothy J; Saldin, Lindsey T; Reing, Janet E; Swinehart, Ilea T; Turner, Neill J; Ratner, Buddy D; Badylak, Stephen F

    2017-03-01

    Biologic scaffolds are derived from mammalian tissues, which must be decellularized to remove cellular antigens that would otherwise incite an adverse immune response. Although widely used clinically, the optimum balance between cell removal and the disruption of matrix architecture and surface ligand landscape remains a considerable challenge. Here we describe the use of time of flight secondary ion mass spectroscopy (ToF-SIMS) to provide sensitive, molecular specific, localized analysis of detergent decellularized biologic scaffolds. We detected residual detergent fragments, specifically from Triton X-100, sodium deoxycholate and sodium dodecyl sulphate (SDS) in decellularized scaffolds; increased SDS concentrations from 0.1% to 1.0% increased both the intensity of SDS fragments and adverse cell outcomes. We also identified cellular remnants, by detecting phosphate and phosphocholine ions in PAA and CHAPS decellularized scaffolds. The present study demonstrates ToF-SIMS is not only a powerful tool for characterization of biologic scaffold surface molecular functionality, but also enables sensitive assessment of decellularization efficacy. We report here on the use of a highly sensitive analytical technique, time of flight secondary ion mass spectroscopy (ToF-SIMS) to characterize detergent decellularized scaffolds. ToF-SIMS detected cellular remnants and residual detergent fragments; increased intensity of the detergent fragments correlated with adverse cell matrix interactions. This study demonstrates the importance of maintaining a balance between cell removal and detergent disruption of matrix architecture and matrix surface ligand landscape. This study also demonstrates the power of ToF-SIMS for the characterization of decellularized scaffolds and capability for assessment of decellularization efficacy. Future use of biologic scaffolds in clinical tissue reconstruction will benefit from the fundamental results described in this work. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  15. Imaging of Crystalline and Amorphous Surface Regions Using Time-of-Flight Secondary-Ion Mass Spectrometry (ToF-SIMS): Application to Pharmaceutical Materials.

    PubMed

    Iuraş, Andreea; Scurr, David J; Boissier, Catherine; Nicholas, Mark L; Roberts, Clive J; Alexander, Morgan R

    2016-04-05

    The structure of a material, in particular the extremes of crystalline and amorphous forms, significantly impacts material performance in numerous sectors such as semiconductors, energy storage, and pharmaceutical products, which are investigated in this paper. To characterize the spatial distribution for crystalline-amorphous forms at the uppermost molecular surface layer, we performed time-of-flight secondary-ion mass spectroscopy (ToF-SIMS) measurements for quench-cooled amorphous and recrystallized samples of the drugs indomethacin, felodipine, and acetaminophen. Polarized light microscopy was used to localize crystallinity induced in the samples under controlled conditions. Principal component analysis was used to identify the subtle changes in the ToF-SIMS spectra indicative of the amorphous and crystalline forms for each drug. The indicators of amorphous and crystalline surfaces were common in type across the three drugs, and could be explained in general terms of crystal packing and intermolecular bonding, leading to intramolecular bond scission in the formation of secondary ions. Less intramolecular scission occurred in the amorphous form, resulting in a greater intensity of molecular and dimer secondary ions. To test the generality of amorphous-crystalline differentiation using ToF-SIMS, a different recrystallization method was investigated where acetaminophen single crystals were recrystallized from supersaturated solutions. The findings indicated that the ability to assign the crystalline/amorphous state of the sample using ToF-SIMS was insensitive to the recrystallization method. This demonstrates that ToF-SIMS is capable of detecting and mapping ordered crystalline and disordered amorphous molecular materials forms at micron spatial resolution in the uppermost surface of a material.

  16. SIM_ADJUST -- A computer code that adjusts simulated equivalents for observations or predictions

    USGS Publications Warehouse

    Poeter, Eileen P.; Hill, Mary C.

    2008-01-01

    This report documents the SIM_ADJUST computer code. SIM_ADJUST surmounts an obstacle that is sometimes encountered when using universal model analysis computer codes such as UCODE_2005 (Poeter and others, 2005), PEST (Doherty, 2004), and OSTRICH (Matott, 2005; Fredrick and others (2007). These codes often read simulated equivalents from a list in a file produced by a process model such as MODFLOW that represents a system of interest. At times values needed by the universal code are missing or assigned default values because the process model could not produce a useful solution. SIM_ADJUST can be used to (1) read a file that lists expected observation or prediction names and possible alternatives for the simulated values; (2) read a file produced by a process model that contains space or tab delimited columns, including a column of simulated values and a column of related observation or prediction names; (3) identify observations or predictions that have been omitted or assigned a default value by the process model; and (4) produce an adjusted file that contains a column of simulated values and a column of associated observation or prediction names. The user may provide alternatives that are constant values or that are alternative simulated values. The user may also provide a sequence of alternatives. For example, the heads from a series of cells may be specified to ensure that a meaningful value is available to compare with an observation located in a cell that may become dry. SIM_ADJUST is constructed using modules from the JUPITER API, and is intended for use on any computer operating system. SIM_ADJUST consists of algorithms programmed in Fortran90, which efficiently performs numerical calculations.

  17. SimSchool: An Opportunity for Using Serious Gaming for Training Teachers in Rural Areas

    ERIC Educational Resources Information Center

    Tyler-Wood, Tandra; Estes, Mary; Christensen, Rhonda; Knezek, Gerald; Gibson, David

    2015-01-01

    This article examines the use of simSchool as a training tool for educators working with students with special needs in rural districts. SimSchool is a game that emulates a classroom utilizing a virtual environment. The theory supporting simSchool is explored and current research associated with simSchool is reviewed. The issues surrounding…

  18. In Situ Characterization of Shewanella oneidensis MR1 Biofilms by SALVI and ToF-SIMS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Komorek, Rachel; Wei, Wenchao; Yu, Xiaofei

    Bacterial biofilms are surface-associated communities that are vastly studied to understand their self-produced extracellular polymeric substances (EPS) and their roles in environmental microbiology. This study outlines a method to cultivate biofilm attachment to the System for Analysis at the Liquid Vacuum Interface (SALVI) and achieve in situ chemical mapping of a living biofilm by time-of-flight secondary ion mass spectrometry (ToF-SIMS). This is done through the culturing of bacteria both outside and within the SALVI channel with our specialized setup, as well as through optical imaging techniques to detect the biofilm presence and thickness before ToF-SIMS analysis. Our results show themore » characteristic peaks of the Shewanella biofilm in its natural hydrated state, highlighting upon its localized water cluster environment, as well as EPS fragments, which are drastically different from the same biofilm’s dehydrated state. These results demonstrate the breakthrough capability of SALVI that allows for in situ biofilm imaging with a vacuum-based chemical imaging instrument.« less

  19. Reduced dental calcium expression and dental mass in chronic sleep deprived rats: Combined EDS, TOF-SIMS, and micro-CT analysis

    NASA Astrophysics Data System (ADS)

    Kuo, Yi-Jie; Huang, Yung-Kai; Chou, Hsiu-Chu; Pai, Man-Hui; Lee, Ai-Wei; Mai, Fu-Der; Chang, Hung-Ming

    2015-08-01

    Teeth are the hardest tissue in the body. The growth of teeth is closely regulated by circadian rhythmicity. Considering that sleep deprivation (SD) is a severe condition that disrupts normal circadian rhythmicity, this study was conducted to determine whether calcium expression (the major element participating in teeth constitution), and dental mass would be significantly impaired following SD. Adolescent rats subjected to 3 weeks of SD were processed for energy dispersive spectrum (EDS), time-of-flight secondary ion mass spectrometry (TOF-SIMS), and micro-computed tomography (micro-CT) analyses. The EDS and TOF-SIMS results indicated that high calcium intensity was detected in both the upper and lower incisors of untreated rats. Micro-CT analysis corresponded closely with spectral data in which an enhanced dental mass was calculated in intact animals. However, following SD, both calcium expression and the dental mass were remarkably decreased to nearly half those of the untreated values. Because SD plays a detrimental role in impairing dental structure, establishing satisfactory sleep behavior would therefore serve as a crucial strategy for preventing or improving prevalent dental dysfunctions.

  20. Ga + TOF-SIMS lineshape analysis for resolution enhancement of MALDI MS spectra of a peptide mixture

    NASA Astrophysics Data System (ADS)

    Malyarenko, D. I.; Chen, H.; Wilkerson, A. L.; Tracy, E. R.; Cooke, W. E.; Manos, D. M.; Sasinowski, M.; Semmes, O. J.

    2004-06-01

    The use of mass spectrometry to obtain molecular profiles indicative of alteration of concentrations of peptides in body fluids is currently the subject of intense investigation. For surface-based time-of-flight mass spectrometry the reliability and specificity of such profiling methods depend both on the resolution of the measuring instrument and on the preparation of samples. The present work is a part of a program to use Ga + beam TOF-SIMS alone, and as an adjunct to MALDI, in the development of reliable protein and peptide markers for diseases. Here, we describe techniques to prepare samples of relatively high-mass peptides, which serve as calibration standards and proxies for biomarkers. These are: Arg8-vasopressin, human angiotensin II, and somatostatin. Their TOF-SIMS spectra show repeatable characteristic features, with mass resolution exceeding 2000, including parent peaks and chemical adducts. The lineshape analysis for high-resolution parent peaks is shown to be useful for filter construction and deconvolution of inferior resolution SELDI-TOF spectra of calibration peptide mixture.

  1. Ablation of Sim1 Neurons Causes Obesity through Hyperphagia and Reduced Energy Expenditure

    PubMed Central

    Xi, Dong; Gandhi, Nilay; Lai, Meizan; Kublaoui, Bassil M.

    2012-01-01

    Single-minded 1 (Sim1) is a transcription factor necessary for development of the paraventricular nucleus of the hypothalamus (PVH). This nucleus is a critical regulator of appetite, energy expenditure and body weight. Previously we showed that Sim1+/− mice and conditional postnatal Sim1−/− mice exhibit hyperphagia, obesity, increased linear growth and susceptibility to diet-induced obesity, but no decrease in energy expenditure. Bilateral ablation of the PVH causes obesity due to hyperphagia and reduced energy expenditure. It remains unknown whether Sim1 neurons regulate energy expenditure. In this study, Sim1cre mice were bred to homozygous inducible diphtheria toxin receptor (iDTR) mice to generate mice expressing the simian DTR in Sim1 cells. In these mice, Sim1 neuron ablation was performed by intracerebroventricular (ICV) injection of diphtheria toxin. Compared to controls, mice with Sim1 neuron ablation became obese (with increased fat mass) on a chow diet due to increased food intake and reduced energy expenditure. In post-injection mice, we observed a strong inverse correlation between the degree of obesity and hypothalamic Sim1 expression. The reduction in baseline energy expenditure observed in these mice was accompanied by a reduction in activity. This reduction in activity did not fully account for the reduced energy expenditure as these mice exhibited decreased resting energy expenditure, decreased body temperature, decreased brown adipose tissue temperature, and decreased UCP1 expression suggesting an impairment of thermogenesis. In injected mice, hypothalamic gene expression of Sim1, oxytocin (OXT) and thyrotropin releasing hormone (TRH) was reduced by about 50%. These results demonstrate that Sim1 neurons in adult mice regulate both food intake and energy expenditure. Based on the body of work in the field, feeding regulation by Sim1 neurons likely occurs in both the PVH and medial amygdala, in contrast to energy expenditure regulation by Sim1 neurons, which likely is localized to the PVH. PMID:22558467

  2. Ablation of Sim1 neurons causes obesity through hyperphagia and reduced energy expenditure.

    PubMed

    Xi, Dong; Gandhi, Nilay; Lai, Meizan; Kublaoui, Bassil M

    2012-01-01

    Single-minded 1 (Sim1) is a transcription factor necessary for development of the paraventricular nucleus of the hypothalamus (PVH). This nucleus is a critical regulator of appetite, energy expenditure and body weight. Previously we showed that Sim1(+/-) mice and conditional postnatal Sim1(-/-) mice exhibit hyperphagia, obesity, increased linear growth and susceptibility to diet-induced obesity, but no decrease in energy expenditure. Bilateral ablation of the PVH causes obesity due to hyperphagia and reduced energy expenditure. It remains unknown whether Sim1 neurons regulate energy expenditure. In this study, Sim1cre mice were bred to homozygous inducible diphtheria toxin receptor (iDTR) mice to generate mice expressing the simian DTR in Sim1 cells. In these mice, Sim1 neuron ablation was performed by intracerebroventricular (ICV) injection of diphtheria toxin. Compared to controls, mice with Sim1 neuron ablation became obese (with increased fat mass) on a chow diet due to increased food intake and reduced energy expenditure. In post-injection mice, we observed a strong inverse correlation between the degree of obesity and hypothalamic Sim1 expression. The reduction in baseline energy expenditure observed in these mice was accompanied by a reduction in activity. This reduction in activity did not fully account for the reduced energy expenditure as these mice exhibited decreased resting energy expenditure, decreased body temperature, decreased brown adipose tissue temperature, and decreased UCP1 expression suggesting an impairment of thermogenesis. In injected mice, hypothalamic gene expression of Sim1, oxytocin (OXT) and thyrotropin releasing hormone (TRH) was reduced by about 50%. These results demonstrate that Sim1 neurons in adult mice regulate both food intake and energy expenditure. Based on the body of work in the field, feeding regulation by Sim1 neurons likely occurs in both the PVH and medial amygdala, in contrast to energy expenditure regulation by Sim1 neurons, which likely is localized to the PVH.

  3. Electron microscopy and forensic practice

    NASA Astrophysics Data System (ADS)

    Kotrlý, Marek; Turková, Ivana

    2013-05-01

    Electron microanalysis in forensic practice ranks among basic applications used in investigation of traces (latents, stains, etc.) from crime scenes. Applying electron microscope allows for rapid screening and receiving initial information for a wide range of traces. SEM with EDS/WDS makes it possible to observe topography surface and morphology samples and examination of chemical components. Physical laboratory of the Institute of Criminalistics Prague use SEM especially for examination of inorganic samples, rarely for biology and other material. Recently, possibilities of electron microscopy have been extended considerably using dual systems with focused ion beam. These systems are applied mainly in study of inner micro and nanoparticles , thin layers (intersecting lines in graphical forensic examinations, analysis of layers of functional glass, etc.), study of alloys microdefects, creating 3D particles and aggregates models, etc. Automated mineralogical analyses are a great asset to analysis of mineral phases, particularly soils, similarly it holds for cathode luminescence, predominantly colour one and precise quantitative measurement of their spectral characteristics. Among latest innovations that are becoming to appear also at ordinary laboratories are TOF - SIMS systems and micro Raman spectroscopy with a resolution comparable to EDS/WDS analysis (capable of achieving similar level as through EDS/WDS analysis).

  4. Surface immobilized antibody orientation determined using ToF-SIMS and multivariate analysis.

    PubMed

    Welch, Nicholas G; Madiona, Robert M T; Payten, Thomas B; Easton, Christopher D; Pontes-Braz, Luisa; Brack, Narelle; Scoble, Judith A; Muir, Benjamin W; Pigram, Paul J

    2017-06-01

    Antibody orientation at solid phase interfaces plays a critical role in the sensitive detection of biomolecules during immunoassays. Correctly oriented antibodies with solution-facing antigen binding regions have improved antigen capture as compared to their randomly oriented counterparts. Direct characterization of oriented proteins with surface analysis methods still remains a challenge however surface sensitive techniques such as Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) provide information-rich data that can be used to probe antibody orientation. Diethylene glycol dimethyl ether plasma polymers (DGpp) functionalized with chromium (DGpp+Cr) have improved immunoassay performance that is indicative of preferential antibody orientation. Herein, ToF-SIMS data from proteolytic fragments of anti-EGFR antibody bound to DGpp and DGpp+Cr are used to construct artificial neural network (ANN) and principal component analysis (PCA) models indicative of correctly oriented systems. Whole antibody samples (IgG) test against each of the models indicated preferential antibody orientation on DGpp+Cr. Cross-reference between ANN and PCA models yield 20 mass fragments associated with F(ab') 2 region representing correct orientation, and 23 mass fragments associated with the Fc region representing incorrect orientation. Mass fragments were then compared to amino acid fragments and amino acid composition in F(ab') 2 and Fc regions. A ratio of the sum of the ToF-SIMS ion intensities from the F(ab') 2 fragments to the Fc fragments demonstrated a 50% increase in intensity for IgG on DGpp+Cr as compared to DGpp. The systematic data analysis methodology employed herein offers a new approach for the investigation of antibody orientation applicable to a range of substrates. Controlled orientation of antibodies at solid phases is critical for maximizing antigen detection in biosensors and immunoassays. Surface-sensitive techniques (such as ToF-SIMS), capable of direct characterization of surface immobilized and oriented antibodies, are under-utilized in current practice. Selection of a small number of mass fragments for analysis, typically pertaining to amino acids, is commonplace in literature, leaving the majority of the information-rich spectra unanalyzed. The novelty of this work is the utilization of a comprehensive, unbiased mass fragment list and the employment of principal component analysis (PCA) and artificial neural network (ANN) models in a unique methodology to prove antibody orientation. This methodology is of significant and broad interest to the scientific community as it is applicable to a range of substrates and allows for direct, label-free characterization of surface bound proteins. Copyright © 2017 Acta Materialia Inc. All rights reserved.

  5. In-situ Isotopic Analysis at Nanoscale using Parallel Ion Electron Spectrometry: A Powerful New Paradigm for Correlative Microscopy

    NASA Astrophysics Data System (ADS)

    Yedra, Lluís; Eswara, Santhana; Dowsett, David; Wirtz, Tom

    2016-06-01

    Isotopic analysis is of paramount importance across the entire gamut of scientific research. To advance the frontiers of knowledge, a technique for nanoscale isotopic analysis is indispensable. Secondary Ion Mass Spectrometry (SIMS) is a well-established technique for analyzing isotopes, but its spatial-resolution is fundamentally limited. Transmission Electron Microscopy (TEM) is a well-known method for high-resolution imaging down to the atomic scale. However, isotopic analysis in TEM is not possible. Here, we introduce a powerful new paradigm for in-situ correlative microscopy called the Parallel Ion Electron Spectrometry by synergizing SIMS with TEM. We demonstrate this technique by distinguishing lithium carbonate nanoparticles according to the isotopic label of lithium, viz. 6Li and 7Li and imaging them at high-resolution by TEM, adding a new dimension to correlative microscopy.

  6. Secondary Ion Mass Spectrometry Imaging of Tissues, Cells, and Microbial Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderton, Christopher R.; Gamble, Lara J.

    2016-03-01

    Mass spectrometry imaging (MSI) techniques are increasingly being utilized within many biological fields, including medicine, pathology, microbial ecology, and more. Of the MSI methods available, secondary ion mass spectrometry (SIMS) offers the highest lateral resolution of any technique. Moreover, SIMS versatility in the number of different operating modes and types of mass spectrometers available has made it an increasing popular method for bio-related measurements. Here, we discuss SIMS ability to image tissues, single cells, and microbes with a particular emphasis on the types chemical and spatial information that can be ascertained by the different types of SIMS instruments and methods.more » The recently developed Fourier transform ion cyclotron resonance (FTICR) SIMS located at PNNL is capable of generating molecular maps of tissues with an unprecedented mass resolving power and mass accuracy, with respect to SIMS measurements. ToF-SIMS can generate chemical maps, where detection of small molecules and fragments can be acquired with an order of magnitude better lateral resolution than the FTICR-SIMS. Furthermore, many of commercially available ToF-SIMS instruments are capable of depth profiling measurements, offering the ability to attain three-dimensional information of one’s sample. The NanoSIMS instrument offers the highest lateral resolution of any MSI method available. In practice, NanoSIMS regularly achieves sub-100 nm resolution of atomic and diatomic secondary ions within biological samples. The strengths of the different SIMS methods are more and more being leveraged in both multimodal-imaging endeavors that use complementary MSI techniques as well with optical, fluorescence, and force microscopy methods.« less

  7. Dyeing regions of oxidative hair dyes in human hair investigated by nanoscale secondary ion mass spectrometry.

    PubMed

    Kojima, Toru; Yamada, Hiromi; Yamamoto, Toshihiko; Matsushita, Yasuyuki; Fukushima, Kazuhiko

    2013-06-01

    To develop more effective oxidative hair coloring products, it is important to understand the localization of colored chromophores, which are formed from oxidative dyes, in the fine structure of hair. However, the dyeing regions of oxidative hair dyes in the fine structure of hair have not been extensively examined. In this study, we investigated the distribution and localization of colored chromophores formed by an oxidative hair coloring product in the fine structure of human hair by using a stable isotope-labeled oxidative dye with nanoscale secondary ion mass spectrometry (NanoSIMS). First, formation of the colored chromophore from a deuterium-labeled oxidative dye was examined by visible spectra similarly to a study of its formation using nonlabeled oxidative dye. Furthermore, the formation of binuclear indo dye containing deuterium in its chemical structure was confirmed using time-of-flight secondary ion mass spectrometry (TOF-SIMS) analysis. As a result of the NanoSIMS image on a cross-sectional dyed hair, although deuterium ions were detected in whole hair cross-section, quite a few of them were detected at particulate regions. These particulate regions of the dyed black hair in which deuterium ions were intensely detected were identified as melanin granules, by comparing the dyeing behaviors of black and white hair. NanoSIMS analysis revealed that melanin granules of black human hair are important dyeing regions in oxidative hair coloring. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Petrochronology in constraining early Archean Earth processes and environments: Barberton greenstone belt, South Africa

    NASA Astrophysics Data System (ADS)

    Grosch, Eugene

    2017-04-01

    Analytical and petrological software developments over the past decade have seen rapid innovation in high-spatial resolution petrological techniques, for example, laser-ablation ICP-MS, secondary ion microprobe (SIMS, nano-SIMS), thermodynamic modelling and electron microprobe microscale mapping techniques (e.g. XMapTools). This presentation will focus on the application of petrochronology to ca. 3.55 to 3.33 billion-year-old metavolcanic and sedimentary rocks of the Onverwacht Group, shedding light on the earliest geologic evolution of the Paleoarchean Barberton greenstone belt (BGB) of South Africa. The field, scientific drilling and petrological research conducted over the past 8 years, aims to illustrate how: (a) LA-ICP-MS and SIMS U-Pb detrital zircon geochronology has helped identify the earliest tectono-sedimentary basin and sediment sources in the BGB, as well as reconstructing geodynamic processes as early as ca. 3.432 billion-years ago; (b) in-situ SIMS multiple sulphur isotope analysis of sulphides across various early Archean rock units help to reconstruct atmospheric, surface and subsurface environments on early Archean Earth and (c) the earliest candidate textural traces for subsurface microbial life can be investigated by in-situ LA-ICP-MS U-Pb dating of titanite, micro-XANES Fe-speciation analysis and metamorphic microscale mapping. Collectively, petrochronology combined with high-resolution field mapping studies, is a powerful multi-disciplinary approach towards deciphering petrogenetic and geodynamic processes preserved in the Paleoarchean Barberton greenstone belt of South Africa, with implications for early Archean Earth evolution.

  9. SIMS: A Hybrid Method for Rapid Conformational Analysis

    PubMed Central

    Gipson, Bryant; Moll, Mark; Kavraki, Lydia E.

    2013-01-01

    Proteins are at the root of many biological functions, often performing complex tasks as the result of large changes in their structure. Describing the exact details of these conformational changes, however, remains a central challenge for computational biology due the enormous computational requirements of the problem. This has engendered the development of a rich variety of useful methods designed to answer specific questions at different levels of spatial, temporal, and energetic resolution. These methods fall largely into two classes: physically accurate, but computationally demanding methods and fast, approximate methods. We introduce here a new hybrid modeling tool, the Structured Intuitive Move Selector (sims), designed to bridge the divide between these two classes, while allowing the benefits of both to be seamlessly integrated into a single framework. This is achieved by applying a modern motion planning algorithm, borrowed from the field of robotics, in tandem with a well-established protein modeling library. sims can combine precise energy calculations with approximate or specialized conformational sampling routines to produce rapid, yet accurate, analysis of the large-scale conformational variability of protein systems. Several key advancements are shown, including the abstract use of generically defined moves (conformational sampling methods) and an expansive probabilistic conformational exploration. We present three example problems that sims is applied to and demonstrate a rapid solution for each. These include the automatic determination of “active” residues for the hinge-based system Cyanovirin-N, exploring conformational changes involving long-range coordinated motion between non-sequential residues in Ribose-Binding Protein, and the rapid discovery of a transient conformational state of Maltose-Binding Protein, previously only determined by Molecular Dynamics. For all cases we provide energetic validations using well-established energy fields, demonstrating this framework as a fast and accurate tool for the analysis of a wide range of protein flexibility problems. PMID:23935893

  10. Preparing strategic information management plans for hospitals: a practical guideline SIM plans for hospitals: a guideline.

    PubMed

    Brigl, B; Ammenwerth, E; Dujat, C; Gräber, S; Grosse, A; Häber, A; Jostes, C; Winter, A

    2005-01-01

    Systematic information management in hospitals demands for a strategic information management plan (SIM plan). As preparing a SIM plan is a considerable challenge we provide a practical guideline that is directly applicable when a SIM plan is going to be prepared. The guideline recommends a detailed structure of a SIM plan and gives advice about its content and the preparation process. It may be used as template, which can be adapted to the individual demands of any hospital. The guideline was used in several hospitals preparing a SIM plan. Experiences showed that the SIM plans could be prepared very efficiently and timely using the guideline, that the proposed SIM plan structure suited well, that the guideline offers enough flexibility to meet the requirements of the individual hospitals and that the specific recommendations of the guideline were very helpful. Nevertheless, we must strive for a more comprehensive theory of strategic information management planning which -- in the sense of enterprise architecture planning -- represents the intrinsic correlations of the different parts of a SIM plan to a greater extent.

  11. Two-dimensional and three-dimensional dynamic imaging of live biofilms in a microchannel by time-of-flight secondary ion mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hua, Xin; Marshall, Matthew J.; Xiong, Yijia

    2015-05-01

    A vacuum compatible microfluidic reactor, SALVI (System for Analysis at the Liquid Vacuum Interface) was employed for in situ chemical imaging of live biofilms using time-of-flight secondary ion mass spectrometry (ToF-SIMS). Depth profiling by sputtering materials in sequential layers resulted in live biofilm spatial chemical mapping. 2D images were reconstructed to report the first 3D images of hydrated biofilm elucidating spatial and chemical heterogeneity. 2D image principal component analysis (PCA) was conducted among biofilms at different locations in the microchannel. Our approach directly visualized spatial and chemical heterogeneity within the living biofilm by dynamic liquid ToF-SIMS.

  12. Structure design for a Two-DoF myoelectric prosthetic hand to realize basic hand functions in ADLs.

    PubMed

    Hoshigawa, Suguru; Jiang, Yinlai; Kato, Ryu; Morishita, Soichiro; Nakamura, Tatsuhiro; Yabuki, Yoshiko; Yokoi, Hiroshi

    2015-01-01

    Prosthetic hands are desired by those who have lost a hand or both hands not only for decoration but also for the functions to help them with their activities of daily living (ADL). Prosthetic robotic hands that are developed to fully realize the function of a human hand are usually too expensive to be economically available, difficult to operate and maintain, or over heavy for longtime wearing. The aim of this study is therefore to develop a simplified prosthetic hand (sim-PH), which is to be controlled by myoelectric signals from the user, to realize the most important grasp motions in ADL by trading off the cost and performance. This paper reports the structure design of a two-DoF sim-PH with two motors to drive the CM joint of the thumb and the interlocked MP joints of the other four fingers. In order to optimize the structure, the model of the sim-PH was proposed based on which 7 sim-PHs with different structural parameters were manufactured and tested in a pick-and-place experiment. Correspondence analysis of the experimental results clarified the relationship between the hand functions and the shapes of fingers.

  13. Identification and High-Resolution Imaging of α-Tocopherol from Human Cells to Whole Animals by TOF-SIMS Tandem Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Bruinen, Anne L.; Fisher, Gregory L.; Balez, Rachelle; van der Sar, Astrid M.; Ooi, Lezanne; Heeren, Ron M. A.

    2018-06-01

    A unique method for identification of biomolecular components in different biological specimens, while preserving the capability for high speed 2D and 3D molecular imaging, is employed to investigate cellular response to oxidative stress. The employed method enables observing the distribution of the antioxidant α-tocopherol and other molecules in cellular structures via time-of-flight secondary ion mass spectrometry (TOF-SIMS (MS1)) imaging in parallel with tandem mass spectrometry (MS2) imaging, collected simultaneously. The described method is employed to examine a network formed by neuronal cells differentiated from human induced pluripotent stem cells (iPSCs), a model for investigating human neurons in vitro. The antioxidant α-tocopherol is identified in situ within different cellular layers utilizing a 3D TOF-SIMS tandem MS imaging analysis. As oxidative stress also plays an important role in mediating inflammation, the study was expanded to whole body tissue sections of M. marinum-infected zebrafish, a model organism for tuberculosis. The TOF-SIMS tandem MS imaging results reveal an increased presence of α-tocopherol in response to the pathogen. [Figure not available: see fulltext.

  14. Final report of the SIM.QM-S7 supplementary comparison, trace metals in drinking water

    NASA Astrophysics Data System (ADS)

    Yang, Lu; Nadeau, Kenny; Gedara Pihillagawa, Indu; Meija, Juris; Grinberg, Patricia; Mester, Zoltan; Valle Moya, Edith; Solís González, Faviola Alejandra; del Rocio Arvizu Torres, María; Yañez Muñoz, Oscar; Velina Lara-Manzano, Judith; Mazzitello, Gisela; Prina, Pedro; Acosta, Osvaldo; Napoli, Romina; Pérez Zambra, Ramiro; Ferreira, Elizabeth; Dobrovolskiy, Vladimir; Aprelev, Aleksei; Stakheev, Aleksei; Frolov, Dmitriy; Gusev, Leonid; Ivanova, Veronika; Näykki, Teemu; Sara-Aho, Timo; Venegas Padilla, Jimmy; Acuña Cubillo, Carlos; Bremmer, Dwyte; Freemantle, Ruel; Taebunpakul, Sutthinun; Tangpaisarnkul, Nongluck; Rodruangthum, Patumporn; Kaewkhomdee, Nattikarn; Thiengmanee, Usana; Tangjit, Tararat; Buzoianu, Mirella; Alejandro Ahumada Forigua, Diego; Abella Gamba, Johanna Paola; Alfredo Chavarro Medina, Luis; Sobina, Egor; Tabatchikova, Tatyana; Alexopoulos, Charalambos; Kakoulides, Elias; Delgado, Mabel; Flores, Liliana; Knox, Saira; Siewlal, Kester; Maharaj, Avinash

    2018-01-01

    SIM.QM-S7 was performed to assess the analytical capabilities of National Metrology Institutes (NMIs) and Designated Institutes (DIs) of SIM members (or other regions) for the accurate determination of trace metals in drinking water. The study was proposed by the coordinating laboratories National Research Council Canada (NRC) and Centro Nacional de Metrologia (CENAM) as an activity of Inorganic Analysis Working Group (IAWG) of Consultative Committee for Amount of Substance - Metrology in Chemistry and Biology (CCQM). Participants included 16 NMIs/DIs from 15 countries. No measurement method was prescribed by the coordinating laboratories. Therefore, NMIs used measurement methods of their choice. However, the majority of NMIs/DIs used ICP-MS. This SIM.QM-S7 Supplementary Comparison provides NMIs/DIs with the needed evidence for CMC claims for trace elements in fresh waters and similar matrices. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. A new case of interstitial 6q16.2 deletion in a patient with Prader-Willi-like phenotype and investigation of SIM1 gene deletion in 87 patients with syndromic obesity.

    PubMed

    Varela, Monica C; Simões-Sato, Alex Y; Kim, Chong A; Bertola, Débora R; De Castro, Claudia I E; Koiffmann, Celia P

    2006-01-01

    The association of obesity, phenotypic abnormalities and mental retardation characterizes syndromic obesity. Its most common form is the Prader-Willi syndrome (PWS-- neonatal hypotonia, poor sucking, delayed psychomotor development, hyperphagia, severe obesity, short stature, small hands and feet, hypogonadism, mild to moderate mental retardation and behavioral disorders). A PWS-like phenotype has been described in patients with chromosome abnormalities involving the chromosome region 6q16.2 that includes the SIM1 gene. Herein we report cytogenetic and gene studies including a screening for the SIM1 gene deletion, performed on 87 patients with PWS-like phenotype, and describe the fifth case of syndromic obesity with an interstitial deletion of the chromosome segment 6q16-q21 and suggest that mutational analysis and further studies of the parental origin of chromosome alterations of 6q16.2 in patients with and without PWS-like phenotype are needed to evaluate possible imprinting effects of SIM1 gene and establish the contribution that alterations in this gene makes to the etiology of syndromic and non-syndromic obesity.

  16. The outlook of physician histories: J. Marion Sims and 'The Discovery of Anaesthesia'.

    PubMed

    Rosenbloom, Julia M; Schonberger, Robert B

    2015-12-01

    The fact that doctors have a long tradition of writing medical history to interpret and direct their profession is well established. But readers (particularly modern physician readers) can also understand physician-authored histories as offering commentary and analysis of the world beyond medicine. In this essay, we offer a reading (perhaps a modern one) of J. Marion Sims's 1877 article, 'The Discovery of Anaesthesia' which exemplifies the stance of looking both inward and outward from the medical field. We begin by discussing Sims, including the complicated legacy he left as a physician. Next, we review late 19th-century history with a focus on Reconstruction. Finally, we show how the modern reader can use Sims's article both to trace the first use of ether and nitrous oxide for surgical anaesthesia and to provide a window into the 19th-century medical profession and the post-Civil War period. Through this study, we hope to show how to read both medicine and the world around it in physician histories. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. Elemental and isotopic imaging of biological samples using NanoSIMS.

    PubMed

    Kilburn, Matt R; Clode, Peta L

    2014-01-01

    With its low detection limits and the ability to analyze most of the elements in the periodic table, secondary ion mass spectrometry (SIMS) represents one of the most versatile in situ analytical techniques available, and recent developments have resulted in significant advantages for the use of imaging mass spectrometry in biological and biomedical research. Increases in spatial resolution and sensitivity allow detailed interrogation of samples at relevant scales and chemical concentrations. Advances in dynamic SIMS, specifically with the advent of NanoSIMS, now allow the tracking of stable isotopes within biological systems at subcellular length scales, while static SIMS combines subcellular imaging with molecular identification. In this chapter, we present an introduction to the SIMS technique, with particular reference to NanoSIMS, and discuss its application in biological and biomedical research.

  18. simDEF: definition-based semantic similarity measure of gene ontology terms for functional similarity analysis of genes.

    PubMed

    Pesaranghader, Ahmad; Matwin, Stan; Sokolova, Marina; Beiko, Robert G

    2016-05-01

    Measures of protein functional similarity are essential tools for function prediction, evaluation of protein-protein interactions (PPIs) and other applications. Several existing methods perform comparisons between proteins based on the semantic similarity of their GO terms; however, these measures are highly sensitive to modifications in the topological structure of GO, tend to be focused on specific analytical tasks and concentrate on the GO terms themselves rather than considering their textual definitions. We introduce simDEF, an efficient method for measuring semantic similarity of GO terms using their GO definitions, which is based on the Gloss Vector measure commonly used in natural language processing. The simDEF approach builds optimized definition vectors for all relevant GO terms, and expresses the similarity of a pair of proteins as the cosine of the angle between their definition vectors. Relative to existing similarity measures, when validated on a yeast reference database, simDEF improves correlation with sequence homology by up to 50%, shows a correlation improvement >4% with gene expression in the biological process hierarchy of GO and increases PPI predictability by > 2.5% in F1 score for molecular function hierarchy. Datasets, results and source code are available at http://kiwi.cs.dal.ca/Software/simDEF CONTACT: ahmad.pgh@dal.ca or beiko@cs.dal.ca Supplementary data are available at Bioinformatics online. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  19. Detection of surface mobility of poly (2, 3, 4, 5, 6-pentafluorostyrene) films by in situ variable-temperature ToF-SIMS and contact angle measurements.

    PubMed

    Fu, Yi; Lau, Yiu-Ting R; Weng, Lu-Tao; Ng, Kai-Mo; Chan, Chi-Ming

    2014-10-01

    Poly (2, 3, 4, 5, 6-pentafluorostyrene) (5FPS) was prepared by bulk radical polymerization. The spin-cast films of this polymer were analyzed using time-of-flight secondary ion mass spectrometry (ToF-SIMS) at various temperatures ranging from room temperature to 120°C. Principal component analysis (PCA) of the ToF-SIMS data revealed a transition temperature (T(T)) at which the surface structure of 5FPS was rearranged. A comparison between the results of the PCA of ToF-SIMS spectra obtained on 5FPS and polystyrene (PS) indicate that the pendant groups of 5FPS and PS moved in exactly opposite directions as the temperature increased. More pendant groups of 5FPS and PS migrated from the bulk to the surface and verse versa, respectively, as the temperature increased. These results clearly support the view that the abrupt changes in the normalized principal component 1 value was caused by the surface reorientation of the polymers and not by a change in the ion fragmentation mechanism at temperatures above the T(T). Contact angle measurement, which is another extremely surface sensitive technique, was used to monitor the change in the surface tension as a function of temperature. A clear T(T) was determined by the contact angle measurements. The T(T) values determined by contact angle measurements and ToF-SIMS were very similar. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Single Cell Profiling using Ionic Liquid Matrix-Enhanced Secondary Ion Mass Spectrometry for Neuronal Cell Type Differentiation

    PubMed Central

    Do, Thanh D.; Comi, Troy J.; Dunham, Sage J. B.; Rubakhin, Stanislav S.; Sweedler, Jonathan V.

    2017-01-01

    A high-throughput single cell profiling method has been developed for matrix-enhanced secondary ion mass spectrometry (ME-SIMS) to investigate the lipid profiles of neuronal cells. Populations of cells are dispersed onto the substrate, their locations determined using optical microscopy, and the cell locations used to guide the acquisition of SIMS spectra from the cells. Up to 2,000 cells can be assayed in one experiment at a rate of 6 s per cell. Multiple saturated and unsaturated phosphatidylcholines (PCs) and their fragments are detected and verified with tandem mass spectrometry from individual cells when ionic liquids are employed as a matrix. Optically guided single cell profiling with ME-SIMS is suitable for a range of cell sizes, from Aplysia californica neurons larger than 75 μm to 7-μm rat cerebellar neurons. ME-SIMS analysis followed by t-distributed stochastic neighbor embedding of peaks in the lipid molecular mass range (m/z 700–850) distinguishes several cell types from the rat central nervous system, largely based on the relative proportions of the four dominant lipids, PC(32:0), PC(34:1), PC(36:1), and PC(38:5). Furthermore, subpopulations within each cell type are tentatively classified consistent with their endogenous lipid ratios. The results illustrate the efficacy of a new approach to classify single cell populations and subpopulations using SIMS profiling of lipid and metabolite contents. These methods are broadly applicable for high throughput single cell chemical analyses. PMID:28194949

  1. Invisible gold in Colombian auriferous soils

    NASA Astrophysics Data System (ADS)

    Bustos Rodriguez, H.; Oyola Lozano, D.; Rojas Martínez, Y. A.; Pérez Alcázar, G. A.; Balogh, A. G.

    2005-11-01

    Optic microscopy, X-ray diffraction (XRD), Mössbauer spectroscopy (MS), Electron microprobe analysis (EPMA) and secondary ions mass spectroscopy (SIMS) were used to study Colombian auriferous soils. The auriferous samples, collected from El Diamante mine, located in Guachavez-Nariño (Colombia), were prepared by means of polished thin sections and polished sections for EPMA and SIMS. Petrography analysis was made using an optical microscope with a vision camera, registering the presence, in different percentages, of the following phases: pyrite, quartz, arsenopyrite, sphalerite, chalcopyrite and galena. By XRD analysis, the same phases were detected and their respective cell parameters calculated. By MS, the presence of two types of pyrite was detected and the hyperfine parameters are: δ 1 = 0.280 ± 0.01 mm/s and Δ Q 1 = 0.642 ± 0.01 mm/s, δ 2 = 0.379 ± 0.01 mm/s and Δ Q 2 = 0.613 ± 0.01 mm/s. For two of the samples MS detected also the arsenopyrite and chalcopyrite presence. The mean composition of the detected gold regions, established by EPMA, indicated 73% Au and 27% Ag (electrum type). Multiple regions of approximately 200 × 200 μm of area in each mineral sample were analyzed by SIMS registering the presence of “invisible gold” associated mainly with the pyrite and occasionally with the arsenopyrite.

  2. Cosensitized Porphyrin System for High-Performance Solar Cells with TOF-SIMS Analysis.

    PubMed

    Wu, Wenjun; Xiang, Huaide; Fan, Wei; Wang, Jinglin; Wang, Haifeng; Hua, Xin; Wang, Zhaohui; Long, Yitao; Tian, He; Zhu, Wei-Hong

    2017-05-17

    To date, development of organic sensitizers has been predominately focused on light harvesting, highest occupied molecular orbital and lowest unoccupied molecular orbital energy levels, and the electron transferring process. In contrast, their adsorption mode as well as the dynamic loading behavior onto nanoporous TiO 2 is rarely considered. Herein, we have employed the time-of-flight secondary ion mass spectrometry (TOF-SIMS) to gain insight into the competitive dye adsorption mode and kinetics in the cosensitized porphyrin system. Using novel porphyrin dye FW-1 and D-A-π-A featured dye WS-5, the different bond-breaking mode in TOF-SIMS and dynamic dye-loading amount during the coadsorption process are well-compared with two different anchoring groups, such as benzoic acid and cyanoacrylic acid. With the bombardment mode in TOF-SIMS spectra, we have speculated that the cyano group grafts onto nanoporous TiO 2 as tridentate binding for the common anchoring unit of cyanoacrylic acid and confirmed it through extensive first-principles density functional theory calculation by anchoring either the carboxyl or cyano group, which shows that the cyano group can efficiently participate in the adsorption of the WS-5 molecule onto the TiO 2 nanocrystal. The grafting reinforcement interaction between the cyano group and TiO 2 in WS-5 can well-explain the rapid adsorption characteristics. A strong coordinate bond between the lone pair of electrons on the nitrogen or oxygen atom and the Lewis acid sites of TiO 2 can increase electron injection efficiencies with respect to those from the bond between the benzoic acid group and the Brønsted acid sites of the TiO 2 surface. Upon optimization of the coadsorption process with dye WS-5, the photoelectric conversion efficiency based on porphyrin dye FW-1 is increased from 6.14 to 9.72%. The study on the adsorption dynamics of organic sensitizers with TOF-SIMS analysis might provide a new venue for improvement of cosensitized solar cells.

  3. A perspective on two chemometrics tools: PCA and MCR, and introduction of a new one: Pattern recognition entropy (PRE), as applied to XPS and ToF-SIMS depth profiles of organic and inorganic materials

    NASA Astrophysics Data System (ADS)

    Chatterjee, Shiladitya; Singh, Bhupinder; Diwan, Anubhav; Lee, Zheng Rong; Engelhard, Mark H.; Terry, Jeff; Tolley, H. Dennis; Gallagher, Neal B.; Linford, Matthew R.

    2018-03-01

    X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS) are much used analytical techniques that provide information about the outermost atomic and molecular layers of materials. In this work, we discuss the application of multivariate spectral techniques, including principal component analysis (PCA) and multivariate curve resolution (MCR), to the analysis of XPS and ToF-SIMS depth profiles. Multivariate analyses often provide insight into data sets that is not easily obtained in a univariate fashion. Pattern recognition entropy (PRE), which has its roots in Shannon's information theory, is also introduced. This approach is not the same as the mutual information/entropy approaches sometimes used in data processing. A discussion of the theory of each technique is presented. PCA, MCR, and PRE are applied to four different data sets obtained from: a ToF-SIMS depth profile through ca. 100 nm of plasma polymerized C3F6 on Si, a ToF-SIMS depth profile through ca. 100 nm of plasma polymerized PNIPAM (poly (N-isopropylacrylamide)) on Si, an XPS depth profile through a film of SiO2 on Si, and an XPS depth profile through a film of Ta2O5 on Ta. PCA, MCR, and PRE reveal the presence of interfaces in the films, and often indicate that the first few scans in the depth profiles are different from those that follow. PRE and backward difference PRE provide this information in a straightforward fashion. Rises in the PRE signals at interfaces suggest greater complexity to the corresponding spectra. Results from PCA, especially for the higher principal components, were sometimes difficult to understand. MCR analyses were generally more interpretable.

  4. The SIM Time Network

    PubMed Central

    Lombardi, Michael A.; Novick, Andrew N.; Lopez R, J. Mauricio; Jimenez, Francisco; de Carlos Lopez, Eduardo; Boulanger, Jean-Simon; Pelletier, Raymond; de Carvalho, Ricardo J.; Solis, Raul; Sanchez, Harold; Quevedo, Carlos Andres; Pascoe, Gregory; Perez, Daniel; Bances, Eduardo; Trigo, Leonardo; Masi, Victor; Postigo, Henry; Questelles, Anthony; Gittens, Anselm

    2011-01-01

    The Sistema Interamericano de Metrologia (SIM) is a regional metrology organization (RMO) whose members are the national metrology institutes (NMIs) located in the 34 nations of the Organization of American States (OAS). The SIM/OAS region extends throughout North, Central, and South America and the Caribbean Islands. About half of the SIM NMIs maintain national standards of time and frequency and must participate in international comparisons in order to establish metrological traceability to the International System (SI) of units. The SIM time network (SIMTN) was developed as a practical, cost effective, and technically sound way to automate these comparisons. The SIMTN continuously compares the time standards of SIM NMIs and produces measurement results in near real-time by utilizing the Internet and the Global Positioning System (GPS). Fifteen SIM NMIs have joined the network as of December 2010. This paper provides a brief overview of SIM and a technical description of the SIMTN. It presents international comparison results and examines the measurement uncertainties. It also discusses the metrological benefits that the network provides to its participants. PMID:26989584

  5. The SIM Time Network.

    PubMed

    Lombardi, Michael A; Novick, Andrew N; Lopez R, J Mauricio; Jimenez, Francisco; de Carlos Lopez, Eduardo; Boulanger, Jean-Simon; Pelletier, Raymond; de Carvalho, Ricardo J; Solis, Raul; Sanchez, Harold; Quevedo, Carlos Andres; Pascoe, Gregory; Perez, Daniel; Bances, Eduardo; Trigo, Leonardo; Masi, Victor; Postigo, Henry; Questelles, Anthony; Gittens, Anselm

    2011-01-01

    The Sistema Interamericano de Metrologia (SIM) is a regional metrology organization (RMO) whose members are the national metrology institutes (NMIs) located in the 34 nations of the Organization of American States (OAS). The SIM/OAS region extends throughout North, Central, and South America and the Caribbean Islands. About half of the SIM NMIs maintain national standards of time and frequency and must participate in international comparisons in order to establish metrological traceability to the International System (SI) of units. The SIM time network (SIMTN) was developed as a practical, cost effective, and technically sound way to automate these comparisons. The SIMTN continuously compares the time standards of SIM NMIs and produces measurement results in near real-time by utilizing the Internet and the Global Positioning System (GPS). Fifteen SIM NMIs have joined the network as of December 2010. This paper provides a brief overview of SIM and a technical description of the SIMTN. It presents international comparison results and examines the measurement uncertainties. It also discusses the metrological benefits that the network provides to its participants.

  6. Space Interferometry Mission: Dynamical Observations of Galaxies (SIMDOG)

    NASA Technical Reports Server (NTRS)

    Shaya, Edward J.; Borne, Kirk D.; Nusser, Adi; Peebles, P. J. E.; Tonry, John; Tully, Brent R.; Vogel, Stuart; Zaritsky, Dennis

    2004-01-01

    Space Interferometry Mission (SIM) will be used to obtain proper motions for a sample of 27 galaxies; the first proper motion measurements of galaxies beyond the satellite system of the Milky Way. SIM measurements lead to knowledge of the full 6-dimensional position and velocity vector of each galaxy. In conjunction with new gravitational flow models, the result will be the first total mass measurements of individual galaxies. The project, includes developnient of powerful theoretical methods for orbital calculations. This SIM study will lead to vastly improved determinations of individual galaxy masses, halo sizes, and the fractional contribution of dark matter. Astronomers have struggled to calculate the orbits of galaxies with only position and redshift information. Traditional N-body techniques are unsuitable for an analysis backward in time from a present distribution if any components of velocity or position are not very precisely known.

  7. Campaign 1.7 Pu Aging. Development of Time of Flight Secondary Ion Mass Spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Venhaus, Thomas J.

    2015-09-09

    The first application of Time-of-Flight Secondary Ion Mass Spectroscopy (ToF-SIMS) to an aged plutonium surface has resulted in a rich set of surface chemistry data, as well as some unexpected results. FY15 was highlighted by not only the first mapping of hydrogen-containing features within the metal, but also a prove-in series of experiments using the system’s Sieverts Reaction Cell. These experiments involved successfully heating the sample to ~450 oC for nearly 24 hours while the sample was dosed several times with hydrogen, followed by an in situ ToF-SIMS analysis. During this year, the data allowed for better and more consistentmore » identification of the myriad peaks that result from the SIMS sputter process. In collaboration with the AWE (U.K), the system was also fully aligned for sputter depth profiling for future experiments.« less

  8. Influence of surface topography on depth profiles obtained with secondary-ion mass spectrometry

    NASA Astrophysics Data System (ADS)

    Walker, A. J.; Borchert, M. T.; Vriezema, C. J.; Zalm, P. C.

    1990-11-01

    Lithographically generated well-defined surface topography of submicron dimensions has been etched into silicon (100) previously implanted with 25 keV 11B to a fluence of 2×1014 atoms/cm2. The thus-obtained samples were depth profiled via secondary-ion mass spectrometry (SIMS). The boron concentration distributions measured were contrasted against those found on undisturbed flat parts of the target. From this intercomparison the otherwise trivial observation that surface topography causes profile distortion becomes suddenly alarming as an apparent improvement of depth resolution occurs. Scanning electron microscope images enable identification of the origin of this remarkable phenomenon. The present results imply that (i) the hitherto commonly accepted assumption in the interpretation of SIMS depth profiles that perceived gradients are never steeper than actual ones is subject to revision; (ii) it may prove very difficult, if not impossible, to construct SIMS equipment for reliable on-chip analysis of submicron details.

  9. XPS and ToF-SIMS analysis of natural rubies and sapphires heat-treated in a reducing (5 mol% H 2/Ar) atmosphere

    NASA Astrophysics Data System (ADS)

    Achiwawanich, S.; James, B. D.; Liesegang, J.

    2008-12-01

    Surface effects on Mong Hsu rubies and Kanchanaburi sapphires after heat treatment in a controlled reducing atmosphere (5 mol% H 2/Ar) have been investigated using advanced surface science techniques including X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). Visual appearance of the gemstones is clearly affected by the heat treatment in a reducing atmosphere. Kanchanaburi sapphires, in particular, exhibit Fe-containing precipitates after the heat treatment which have not been observed in previous studies under an inert atmosphere. Significant correlation between changes in visual appearance of the gemstones and variations in surface concentration of trace elements, especially Ti and Fe are observed. The XPS and ToF-SIMS results suggest that; (1) a reducing atmosphere affects the oxidation state of Fe; (2) dissociation of Fe-Ti interaction may occur during heat treatment.

  10. Estimating local scaling properties for the classification of interstitial lung disease patterns

    NASA Astrophysics Data System (ADS)

    Huber, Markus B.; Nagarajan, Mahesh B.; Leinsinger, Gerda; Ray, Lawrence A.; Wismueller, Axel

    2011-03-01

    Local scaling properties of texture regions were compared in their ability to classify morphological patterns known as 'honeycombing' that are considered indicative for the presence of fibrotic interstitial lung diseases in high-resolution computed tomography (HRCT) images. For 14 patients with known occurrence of honeycombing, a stack of 70 axial, lung kernel reconstructed images were acquired from HRCT chest exams. 241 regions of interest of both healthy and pathological (89) lung tissue were identified by an experienced radiologist. Texture features were extracted using six properties calculated from gray-level co-occurrence matrices (GLCM), Minkowski Dimensions (MDs), and the estimation of local scaling properties with Scaling Index Method (SIM). A k-nearest-neighbor (k-NN) classifier and a Multilayer Radial Basis Functions Network (RBFN) were optimized in a 10-fold cross-validation for each texture vector, and the classification accuracy was calculated on independent test sets as a quantitative measure of automated tissue characterization. A Wilcoxon signed-rank test was used to compare two accuracy distributions including the Bonferroni correction. The best classification results were obtained by the set of SIM features, which performed significantly better than all the standard GLCM and MD features (p < 0.005) for both classifiers with the highest accuracy (94.1%, 93.7%; for the k-NN and RBFN classifier, respectively). The best standard texture features were the GLCM features 'homogeneity' (91.8%, 87.2%) and 'absolute value' (90.2%, 88.5%). The results indicate that advanced texture features using local scaling properties can provide superior classification performance in computer-assisted diagnosis of interstitial lung diseases when compared to standard texture analysis methods.

  11. Economic analysis of standard interface modules for use with the multi-mission spacecraft, volume 1

    NASA Technical Reports Server (NTRS)

    1976-01-01

    A preliminary technical and economic feasibility study was made of the use of Standardized Interstate Modules (SIM) to perform electual interfacing functions that were historically incorporated into sensors. Sensor interface functions that are capable of standardization from the set of missions planned for the NASA Multi-Mission Spacecraft (MMS) in the 1981 to 1985 time period were identified. The cost savings that could be achieved through the replacement of nonstandard sensor interface flight hardware that might be used in these missions with SIM were examined.

  12. Using a simulation cell for exercise realism.

    PubMed

    Lerner, Ken

    2013-01-01

    A simulation cell or SimCell is an effective and flexible tool for control of emergency management exercises. It allows exercise participants to interact, via simulation, with a wide variety of nonplaying organizations and officials. Adapted from military application, the Chemical Stockpile Emergency Preparedness Program (CSEPP) applied, developed, and refined the SimCell concept for emergency management exercises. It has now been incorporated into national exercise guidance through the Homeland Security Exercise and Evaluation Program, and has been used in a wide variety of national, regional, and local exercises. This article reviews development of the SimCell concept in CSEPP, briefly surveys current practice incorporating SimCells in exercise control, and offers practical lessons-learned and tips on using a SimCell to best advantage. Lessons learned include using a SimCell as an exercise-control hub; preparing inject material for exercise controllers as part of the Master Scenario Event List; laying the groundwork for success through exercise player and controller training; developing protocol for SimCell communications; and capturing feedback from SimCell controllers for inclusion in the exercise evaluation reporting process. The SimCell concept is flexible and can be applied to a variety of exercise types and through a variety of methods.

  13. Establishing the Capability of a 1D SVAT Modelling Scheme in Predicting Key Biophysical Vegetation Characterisation Parameters

    NASA Astrophysics Data System (ADS)

    Ireland, Gareth; Petropoulos, George P.; Carlson, Toby N.; Purdy, Sarah

    2015-04-01

    Sensitivity analysis (SA) consists of an integral and important validatory check of a computer simulation model before it is used to perform any kind of analysis. In the present work, we present the results from a SA performed on the SimSphere Soil Vegetation Atmosphere Transfer (SVAT) model utilising a cutting edge and robust Global Sensitivity Analysis (GSA) approach, based on the use of the Gaussian Emulation Machine for Sensitivity Analysis (GEM-SA) tool. The sensitivity of the following model outputs was evaluated: the ambient CO2 concentration and the rate of CO2 uptake by the plant, the ambient O3 concentration, the flux of O3 from the air to the plant/soil boundary, and the flux of O3 taken up by the plant alone. The most sensitive model inputs for the majority of model outputs were related to the structural properties of vegetation, namely, the Leaf Area Index, Fractional Vegetation Cover, Cuticle Resistance and Vegetation Height. External CO2 in the leaf and the O3 concentration in the air input parameters also exhibited significant influence on model outputs. This work presents a very important step towards an all-inclusive evaluation of SimSphere. Indeed, results from this study contribute decisively towards establishing its capability as a useful teaching and research tool in modelling Earth's land surface interactions. This is of considerable importance in the light of the rapidly expanding use of this model worldwide, which also includes research conducted by various Space Agencies examining its synergistic use with Earth Observation data towards the development of operational products at a global scale. This research was supported by the European Commission Marie Curie Re-Integration Grant "TRANSFORM-EO". SimSphere is currently maintained and freely distributed by the Department of Geography and Earth Sciences at Aberystwyth University (http://www.aber.ac.uk/simsphere). Keywords: CO2 flux, ambient CO2, O3 flux, SimSphere, Gaussian process emulators, BACCO GEM-SA, TRANSFORM-EO.

  14. CalSimHydro Tool - A Web-based interactive tool for the CalSim 3.0 Hydrology Prepropessor

    NASA Astrophysics Data System (ADS)

    Li, P.; Stough, T.; Vu, Q.; Granger, S. L.; Jones, D. J.; Ferreira, I.; Chen, Z.

    2011-12-01

    CalSimHydro, the CalSim 3.0 Hydrology Preprocessor, is an application designed to automate the various steps in the computation of hydrologic inputs for CalSim 3.0, a water resources planning model developed jointly by California State Department of Water Resources and United States Bureau of Reclamation, Mid-Pacific Region. CalSimHydro consists of a five-step FORTRAN based program that runs the individual models in succession passing information from one model to the next and aggregating data as required by each model. The final product of CalSimHydro is an updated CalSim 3.0 state variable (SV) DSS input file. CalSimHydro consists of (1) a Rainfall-Runoff Model to compute monthly infiltration, (2) a Soil moisture and demand calculator (IDC) that estimates surface runoff, deep percolation, and water demands for natural vegetation cover and various crops other than rice, (3) a Rice Water Use Model to compute the water demands, deep percolation, irrigation return flow, and runoff from precipitation for the rice fields, (4) a Refuge Water Use Model that simulates the ponding operations for managed wetlands, and (5) a Data Aggregation and Transfer Module to aggregate the outputs from the above modules and transfer them to the CalSim SV input file. In this presentation, we describe a web-based user interface for CalSimHydro using Google Earth Plug-In. The CalSimHydro tool allows users to - interact with geo-referenced layers of the Water Budget Areas (WBA) and Demand Units (DU) displayed over the Sacramento Valley, - view the input parameters of the hydrology preprocessor for a selected WBA or DU in a time series plot or a tabular form, - edit the values of the input parameters in the table or by downloading a spreadsheet of the selected parameter in a selected time range, - run the CalSimHydro modules in the backend server and notify the user when the job is done, - visualize the model output and compare it with a base run result, - download the output SV file to be used to run CalSim 3.0. The CalSimHydro tool streamlines the complicated steps to configure and run the hydrology preprocessor by providing a user-friendly visual interface and back-end services to validate user inputs and manage the model execution. It is a powerful addition to the new CalSim 3.0 system.

  15. Simvastatin Prodrug Micelles Target Fracture and Improve Healing

    PubMed Central

    Dusad, Anand; Yuan, Hongjiang; Ren, Ke; Li, Fei; Fehringer, Edward V.; Purdue, P. Edward; Goldring, Steven R.; Daluiski, Aaron; Wang, Dong

    2014-01-01

    Simvastatin (SIM), a widely used anti-lipidaemic drug, has been identified as a bone anabolic agent. Its poor water solubility and the lack of distribution to the skeleton, however, have limited its application in the treatment of bone metabolic diseases. In this study, an amphiphilic macromolecular prodrug of SIM was designed and synthesized to overcome these limitations. The polyethylene glycol (PEG)-based prodrug can spontaneously self-assemble to form micelles. The use of SIM trimer as the prodrug’s hydrophobic segment allows easy encapsulation of additional free SIM. The in vitro studies showed that SIM/SIM-mPEG micelles were internalized by MC3T3 cells via lysosomal trafficking and consistently induced expression of both BMP2 and DKK1 mRNA, suggesting that the prodrug micelle retains the biological functions of SIM. After systemic administration, optical imaging suggests that the micelles would passively target to bone fracture sites associated with hematoma and inflammation. Furthermore, flow cytometry study revealed that SIM/SIM-mPEG micelles had preferred cellular uptake by inflammatory and resident cells within the fracture callus tissue. The treatment study using a mouse osteotomy model validated the micelles’ therapeutic efficacy in promoting bone fracture healing as demonstrated by micro-CT and histological analyses. Collectively, these data suggest that the macromolecular prodrug-based micelle formulation of SIM may have great potential for clinical management of impaired fracture healing. PMID:25542644

  16. A test-tube model for rainfall

    NASA Astrophysics Data System (ADS)

    Wilkinson, Michael

    2014-05-01

    If the temperature of a cell containing two partially miscible liquids is changed very slowly, so that the miscibility is decreased, microscopic droplets nucleate, grow and migrate to the interface due to their buoyancy. The system may show an approximately periodic variation of the turbidity of the mixture, as the mean droplet size fluctuates. These precipitation events are analogous to rainfall. This paper considers a theoretical model for these experiments. After nucleation the initial growth is by Ostwald ripening, followed by a finite-time runaway growth of droplet sizes due to larger droplets sweeping up smaller ones. The model predicts that the period \\Delta t and the temperature sweep rate ξ are related by \\Delta t\\sim C \\xi^{-3/7} , and is in good agreement with experiments. The coefficient C has a power-law divergence approaching the critical point of the miscibility transition: C\\sim (T-T_{\\text{c}})^{-\\eta} , and the critical exponent η is determined. It is argued that while the mechanism does not provide a quantitative description of terrestrial rainfall, it may be a faithful model for precipitation on other planets.

  17. Predictors of food decision making: A systematic interdisciplinary mapping (SIM) review.

    PubMed

    Symmank, Claudia; Mai, Robert; Hoffmann, Stefan; Stok, F Marijn; Renner, Britta; Lien, Nanna; Rohm, Harald

    2017-03-01

    The number of publications on consumer food decision making and its predictors and correlates has been steadily increasing over the last three decades. Given that different scientific disciplines illuminate this topic from different perspectives, it is necessary to develop an interdisciplinary overview. The aim of this study is to conduct a systematic interdisciplinary mapping (SIM) review by using rapid review techniques to explore the state-of-the-art, and to identify hot topics and research gaps in this field. This interdisciplinary review includes 1,820 publications in 485 different journals and other types of publications from more than ten disciplines (including nutritional science, medicine/health science, psychology, food science and technology, business research, etc.) across a period of 60 years. The identified predictors of food decision making were categorized in line with the recently proposed DONE (Determinants Of Nutrition and Eating behavior) framework. After applying qualitative and quantitative analyses, this study reveals that most of the research emphasizes biological, psychological, and product-related predictors, whereas policy-related influences on food choice are scarcely considered. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Crystallization of Sr0.5Ba0.5Nb2O6 Thin Films on LaNiO3 Electrodes by RF Magnetron Reactive Sputtering

    NASA Astrophysics Data System (ADS)

    Jong, Chao-An; Gan, Jon-Yiew

    2000-02-01

    Strontium barium niobium (Sr0.5Ba0.5Nb2O6) (SBN) thin films are prepared on conductive-oxide LNO (LaNiO3) electrodes by the rf magnetron sputtering system. Instead of conventional furnace annealing, SBN thin films are crystallized by rapid thermal annealing (RTA) above 700°C for 5 min. The textured SBN films are crystallized with two orientations: one is the (001) or (310) direction, and the other is the (002) or (620) direction. Films compositions measured by the electron spectroscopy of chemical analysis (ESCA) quantitative analysis method show nearly the same stoichiometric ratio as the target. The depth profiles of SBN films and the target are examined by secondary ion mass spectrometer (SIMS). The concentrations of the films are quite uniform. After being heat treated at 800°C for 5 min by RTA, La and Ni diffuse into the SBN film. The diffusion coefficient of La in SBN films is also calculated.

  19. Reference Materials for Trace Element Microanalysis of Carbonates by SIMS and other Mass Spectrometric Techniques

    NASA Astrophysics Data System (ADS)

    Layne, G. D.

    2009-12-01

    Today, many areas of geochemical research utilize microanalytical determinations of trace elements in carbonate minerals. In particular, there has been an explosion in the application of Secondary Ion Mass Spectrometry (SIMS) to studies of marine biomineralization. SIMS provides highly precise determinations of Mg and Sr at the concentration levels normally encountered in corals, mollusks or fish otoliths. It is also a highly effective means for determining a wide range of other trace elements at ppm levels (e.g., Na, Fe, Mn, Ba, REE, Pb, Th, and U) in a variety of naturally occurring calcite and aragonite matrices - and so is potentially valuable in studies of diagenesis, hydrothermal fluids and carbonatitic magmas. For SIMS, modest time per spot (often <5 min), lateral spatial resolution (<10 μm), sample volume consumption (<10 ng) and overall reproducibility compare extremely favorably with other microanalytical techniques for these applications. However, accuracy and reproducibility are currently wholly limited by the homogeneity of available solid reference material - which is far inferior to the tenths of a percent levels of precision achieved by SIMS. Due to variation in the sputtered ion yields of most elements with the major element composition of the sample matrix, accuracy of SIMS depends intimately on matrix-matched solid reference materials. Despite its rapidly increasing use for trace element analyses of carbonates, there remains a dearth of certified reference materials suitable for calibrating SIMS. The pressed powders used by some analysts to calibrate LA-ICP-MS do not perform well for SIMS - they are not perfectly dense or homogeneous to the desired level at the micron scale of sampling. Further, they often prove incompatible with the sample high vacuum compatibility requirement for stable SIMS analysis (10-8 to 10-9 torr). Some naturally occurring calcite has apparent utility as a reference material. For example, equigranular calcite from some zones of carbonatite intrusions (sovites) and recrystallized calcites from highly metamorphosed metallic ore deposits. Most calcite marbles, though possibly appropriate as Sr standards, show substantial inhomogeneity in Mg, Mn and Ba. Some hydrothermal “Iceland Spar” calcite may prove useful as a reference for extremely low concentrations of Mg, Sr and Ba. The best carbonatitic calcites currently in use appear homogeneous to better than 2-3% for Sr (and somewhat less homogeneous for Mg). But these standards still require numerous replicate analyses during analytical sessions to reduce the overall uncertainty to <<1.0%.The availability of appropriate certified solid reference materials with a high degree of homogeneity would greatly benefit the utilization and inter-comparison of SIMS determinations in carbonates, while substantially reducing the time consumed in calibration. Some studies would also benefit from the extension of this effort to the characterization of appropriate standards of other rhombohedral carbonates (especially dolomite and Fe-rich calcite).

  20. A multi-residue method for pesticides analysis in green coffee beans using gas chromatography-negative chemical ionization mass spectrometry in selective ion monitoring mode.

    PubMed

    Pizzutti, Ionara R; de Kok, Andre; Dickow Cardoso, Carmem; Reichert, Bárbara; de Kroon, Marijke; Wind, Wouter; Weber Righi, Laís; Caiel da Silva, Rosselei

    2012-08-17

    In this study, a new gas chromatography-mass spectrometry (GC-MS) method, using the very selective negative chemical ionization (NCI) mode, was developed and applied in combination with a modified acetonitrile-based extraction method (QuEChERS) for the analysis of a large number of pesticide residues (51 pesticides, including isomers and degradation products) in green coffee beans. A previously developed integrated sample homogenization and extraction method for both pesticides and mycotoxins analysis was used. An homogeneous slurry of green milled coffee beans and water (ratio 1:4, w/w) was prepared and extracted with acetonitrile/acetic acid (1%), followed by magnesium sulfate addition for phase separation. Aliquots from this extract could be used directly for LC-MS/MS analysis of mycotoxins and LC-amenable pesticides. For GC-MS analysis, a further clean-up was necessary. C18- and PSA-bonded silica were tested as dispersive solid-phase extraction (d-SPE) sorbents, separate and as a mixture, and the best results were obtained using C18-bonded silica. For the optimal sensitivity and selectivity, GC-MS detection in the NCI-selected ion monitoring (SIM) mode had to be used to allow the fast analysis of the difficult coffee bean matrix. The validation was performed by analyzing recovery samples at three different spike concentrations, 10, 20 and 50 μg kg(-1), with 6 replicates (n=6) at each concentration. Linearity (r(2)) of calibration curves, estimated instrument and method limits of detection and limits of quantification (LOD(i), LOD(m), LOQ(i) and LOQ(m), respectively), accuracy (as recovery %), precision (as RSD%) and matrix effects (%) were determined for each individual pesticide. From the 51 analytes (42 parent pesticides, 4 isomers and 5 degradation products) determined by GC-MS (NCI-SIM), approximately 76% showed average recoveries between 70-120% and 75% and RSD ≤ 20% at the lowest spike concentration of 10 μg kg(-1), the target method LOQ. For the spike concentrations of 20 and 50 μg kg(-1), the recoveries and RSDs were even better. The validated LOQ(m) was 10, 20 and 50 μg kg(-1) for respectively 33, 3 and 6 of the analytes studied. For five compounds, the European Union method performance requirements for the validation of a quantitative method (average recoveries between 70-120% and repeatability RSD ≤ 20%) were not achieved and 4 problematic pesticides (captan, captafol, folpet and dicofol) could not be detected as their parent compound, but only via their degradation products. Although the matrix effect (matrix-enhanced detector response) was high for all pesticides studied, the matrix interference was minimal, due to the high selectivity obtained with the GC-NCI-MS detection. Matrix-matched calibration for applying the method in routine analysis is recommended for reliable quantitative results. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Lakeside: Merging Urban Design with Scientific Analysis

    ScienceCinema

    Guzowski, Leah; Catlett, Charlie; Woodbury, Ed

    2018-01-16

    Researchers at the U.S. Department of Energy's Argonne National Laboratory and the University of Chicago are developing tools that merge urban design with scientific analysis to improve the decision-making process associated with large-scale urban developments. One such tool, called LakeSim, has been prototyped with an initial focus on consumer-driven energy and transportation demand, through a partnership with the Chicago-based architectural and engineering design firm Skidmore, Owings & Merrill, Clean Energy Trust and developer McCaffery Interests. LakeSim began with the need to answer practical questions about urban design and planning, requiring a better understanding about the long-term impact of design decisions on energy and transportation demand for a 600-acre development project on Chicago's South Side - the Chicago Lakeside Development project.

  2. TOF-SIMS Analysis of Crater Residues from Wild 2 Cometary on Stardust Aluminum Foil

    NASA Technical Reports Server (NTRS)

    Leutner, Jan; Stephan, Thomas; Kearsley, T.; Horz, Friedrich; Flynn, George J.; Sandford, Scott A.

    2006-01-01

    Impact residues of cometary particles on aluminum foils from the Stardust mission were investigated with TOF-SIMS for their elemental and organic composition. The residual matter from comet 81P/Wild 2 shows a wide compositional range, from nearly monomineralic grains to polymict aggregates. Despite the comparably small analyzed sample volume, the average element composition of the investigated residues is similar to bulk CI chondritic values. Analysis of organic components in impact residues is complicated, due to fragmentation and alteration of the compounds during the impact process and by the presence of contaminants on the aluminum foils. Nevertheless, polycyclic aromatic hydrocarbons (PAHs) that are unambiguously associated with the impact residues were observed, and thus are most likely of cometary origin.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yao, Juan; Zhou, Yufan; Sui, Xiao

    Switchable ionic liquids (SWIL) play an important role in green chemistry. Due to the nature of SWIL chemistry, such as air sensitivity and pressure and temperature dependence, it is difficult to characterize SWIL using vacuum-based surface techniques. The fully CO2 loaded and none-loaded DBU and hexanol mixtures, a SWIL system, were analyzed in situ by time-of-flight secondary ion mass spectrometry (ToF-SIMS) coupled with the System for Analysis at the Liquid Vacuum Interface (SALVI), respectively. The DBU/Hexanol/CO2 SWIL was injected into the microchannel before liquid SIMS analysis. Bi3+ primary ion beam was used. The positive and negative spectra of the SWILmore » chemical components are presented. The characteristic peaks m/z 153 (reduced DBU) in the positive mode and m/z 101 (oxidized hexanol) in negative mode were observed. In addition, ion pair peaks including m/z 253, 319, 305, 451 in the positive mode and m/z 145, 223, 257 in the negative mode are first observed using this approach. These results demonstrate that the SALVI microfluidic reactor enables the vacuum-based surface technique (i.e., ToF-SIMS) for in situ characterization of challenging liquid samples such as ionic liquids.« less

  4. Surface analysis and depth profiling of corrosion products formed in lead pipes used to supply low alkalinity drinking water.

    PubMed

    Davidson, C M; Peters, N J; Britton, A; Brady, L; Gardiner, P H E; Lewis, B D

    2004-01-01

    Modern analytical techniques have been applied to investigate the nature of lead pipe corrosion products formed in pH adjusted, orthophosphate-treated, low alkalinity water, under supply conditions. Depth profiling and surface analysis have been carried out on pipe samples obtained from the water distribution system in Glasgow, Scotland, UK. X-ray diffraction spectrometry identified basic lead carbonate, lead oxide and lead phosphate as the principal components. Scanning electron microscopy/energy-dispersive x-ray spectrometry revealed the crystalline structure within the corrosion product and also showed spatial correlations existed between calcium, iron, lead, oxygen and phosphorus. Elemental profiling, conducted by means of secondary ion mass spectrometry (SIMS) and secondary neutrals mass spectrometry (SNMS) indicated that the corrosion product was not uniform with depth. However, no clear stratification was apparent. Indeed, counts obtained for carbonate, phosphate and oxide were well correlated within the depth range probed by SIMS. SNMS showed relationships existed between carbon, calcium, iron, and phosphorus within the bulk of the scale, as well as at the surface. SIMS imaging confirmed the relationship between calcium and lead and suggested there might also be an association between chloride and phosphorus.

  5. Health, drugs and service use among deprived single men: comparing (subgroups) of single male welfare recipients against employed single men in Amsterdam.

    PubMed

    Kamann, Tjerk C; de Wit, Matty A S; Cremer, Stephan; Beekman, Aartjan T F

    2014-02-20

    To aid public health policy in preventing severe social exclusion (like homelessness) and promoting social inclusion (like labour market participation), we aimed to quantify (unmet) health needs of an expectedly vulnerable population on which little was known about: single male welfare recipients (SIM-welfare). One of the main policy questions was: is there need to promote access to healthcare for this specific group? A cross-sectional study incorporating peer-to-peer methodology to approach and survey SIM-welfare. Sociodemographics, prevalence of ill health, harmful drug use and healthcare utilisation for subgroups of SIM-welfare assessed with a different distance to the labour market and exposed to different reintegration policy were described and compared against single employed men (SIM-work). Men between the age of 23 and 64, living in single person households in Amsterdam. A random and representative sample of 472 SIM-welfare was surveyed during 2009-2010. A reference sample of 212 SIM-work was taken from the 2008 Amsterdam Health Survey. Standardised instruments were used to assess self-reported ill somatic and mental health, harmful drug use and service use. SIM-welfare are mostly long-term jobless, low educated, older men; 70% are excluded from re-employment policy due to multiple personal barriers. Health: 50% anxiety and depression; 47% harmful drug use; 41% multiple somatic illnesses. Health differences compared with SIM-work: (1) controlled for background characteristics, SIM-welfare report more mental (OR 4.0; 95% CI 2.1 to 4.7) and somatic illnesses (OR 3.1; 95% CI 2.7 to 6.0); (2) SIM-welfare assessed with the largest distance to the labour market report most combined health problems. Controlled for ill health, SIM-welfare are more likely to have service contacts than SIM-work. SIM-welfare form a selection of men with disadvantaged human capital and health. Findings do not support a need to improve access to healthcare. The stratification of welfare clients distinguishes between health needs.

  6. Health, drugs and service use among deprived single men: comparing (subgroups) of single male welfare recipients against employed single men in Amsterdam

    PubMed Central

    Kamann, Tjerk C; de Wit, Matty A S; Cremer, Stephan; Beekman, Aartjan T F

    2014-01-01

    Objectives To aid public health policy in preventing severe social exclusion (like homelessness) and promoting social inclusion (like labour market participation), we aimed to quantify (unmet) health needs of an expectedly vulnerable population on which little was known about: single male welfare recipients (SIM-welfare). One of the main policy questions was: is there need to promote access to healthcare for this specific group? Design A cross-sectional study incorporating peer-to-peer methodology to approach and survey SIM-welfare. Sociodemographics, prevalence of ill health, harmful drug use and healthcare utilisation for subgroups of SIM-welfare assessed with a different distance to the labour market and exposed to different reintegration policy were described and compared against single employed men (SIM-work). Setting Men between the age of 23 and 64, living in single person households in Amsterdam. Participants A random and representative sample of 472 SIM-welfare was surveyed during 2009–2010. A reference sample of 212 SIM-work was taken from the 2008 Amsterdam Health Survey. Outcome measures Standardised instruments were used to assess self-reported ill somatic and mental health, harmful drug use and service use. Results SIM-welfare are mostly long-term jobless, low educated, older men; 70% are excluded from re-employment policy due to multiple personal barriers. Health: 50% anxiety and depression; 47% harmful drug use; 41% multiple somatic illnesses. Health differences compared with SIM-work: (1) controlled for background characteristics, SIM-welfare report more mental (OR 4.0; 95% CI 2.1 to 4.7) and somatic illnesses (OR 3.1; 95% CI 2.7 to 6.0); (2) SIM-welfare assessed with the largest distance to the labour market report most combined health problems. Controlled for ill health, SIM-welfare are more likely to have service contacts than SIM-work. Conclusions SIM-welfare form a selection of men with disadvantaged human capital and health. Findings do not support a need to improve access to healthcare. The stratification of welfare clients distinguishes between health needs. PMID:24556242

  7. Highly sensitive and selective analysis of urinary steroids by comprehensive two-dimensional gas chromatography combined with positive chemical ionization quadrupole mass spectrometry

    PubMed Central

    Zhang, Ying; Tobias, Herbert J.; Brenna, J. Thomas

    2014-01-01

    Comprehensive two dimensional gas chromatography (GC×GC) provides greater separation space than conventional GC. Because of fast peak elution, a time of flight mass spectrometer (TOFMS) is the usual structure-specific detector of choice. The quantitative capabilities of a novel GC×GC fast quadrupole MS were investigated with electron ionization (EI), and CH4 or NH3 positive chemical ionization (PCI) for analysis of endogenous urinary steroids targeted in anti-doping tests. Average precisions for steroid quantitative analysis from replicate urine extractions were 6% (RSD) for EI and 8% for PCI-NH3. The average limits of detection (LOD) calculated by quantification ions for 12 target steroids spiked into steroid-free urine matrix (SFUM) were 2.6 ng mL−1 for EI, 1.3 ng mL−1 for PCI-CH4, and 0.3 ng mL−1 for PCI-NH3, all in mass scanning mode. The measured limits of quantification (LOQ) with full mass scan GC×GC-qMS were comparable with the LOQ values measured by one-dimensional GC-MS in single ion monitoring (SIM) mode. PCI-NH3 yields fewer fragments and greater (pseudo)molecular ion abundances than EI or PCI-CH4. These data show a benchtop GC×GC-qMS system has the sensitivity, specificity, and resolution to analyze urinary steroids at normal urine concentrations, and that PCI-NH3, not currently available on most GC×GC-TOFMS instruments, is of particular value for generation of structure-specific ions. PMID:22606686

  8. Quantifying the contribution of single microbial cells to nitrogen assimilation in aquatic environments

    NASA Astrophysics Data System (ADS)

    Musat, N.; Kuypers, M. M. M.

    2009-04-01

    Nitrogen is a primary productivity-limiting nutrient in the ocean. The nitrogen limitation of productivity may be overcome by organisms capable of converting dissolved N2 into fixed nitrogen available to the ecosystem. In many oceanic regions, growth of phytoplankton is nitrogen limited because fixation of N2 cannot make up for the removal of fixed inorganic nitrogen (NH4+, NO2-, NO3-) by anaerobic microbial processes. The amount of available fixed nitrogen in the ocean can be changed by the biological processes of heterotrophic denitrification, anaerobic ammonium oxidation and nitrogen fixation. For a complete understanding of nitrogen cycling in the ocean a link between the microbial and biogeochemical processes at the single cell level and their role in global biogeochemical cycles is essential. Here we report a recently developed method, Halogen In Situ Hybridization-Secondary Ion Mass Spectroscopy (HISH-SIMS) and its potential application to study the nitrogen-cycle processes in the ocean. The method allows simultaneous phylogenetic identification and quantitation of metabolic activities of single microbial cells in the environment. It uses horseradish-peroxidase-labeled oligonucleotide probes and fluorine-containing tyramides for the identification of microorganisms in combination with stable-isotope-labeling experiments for analyzing the metabolic function of single microbial cells. HISH-SIMS was successfully used to study nitrogen assimilation and nitrogen fixation by anaerobic phototrophs in a meromictic alpine lake. The HISH-SIMS method enables studies of the ecophysiology of individual, phylogenetically identified microorganisms involved in the N-cycle and allows us to track the flow of nitrogen within microbial communities.

  9. Laser acupuncture causes thermal changes in small intestine meridian pathway.

    PubMed

    de Souza, Regina Célia; Pansini, Mario; Arruda, Gisele; Valente, Caroline; Brioschi, Marcos Leal

    2016-11-01

    The acupuncture meridians represent the flow of corporal energy which contains the acupuncture points. Laser acupuncture is a form of acupuncture stimulation by the use of laser. Thermographic images represent the propagation of heat in micro-environmental systems. The objective of this study was to investigate the use of thermographic images to document the changes on the small intestine meridian (S.I.M.) when submitted to laser acupuncture. Another important issue regards to the analysis of the flow direction if it is upward when stimulated by acupuncture points. For the execution of this work, a laser acupuncture pen was used in points of the meridian in the S.I.M. Two healthy male volunteers were selected (18 and 60 years old, respectively), and doses of 576,92 J/cm 2 with low-power infrared laser equipment with a wavelength of 780 nm in the SI.3 and SI.19 points were applied. An infrared thermal camera was used to measure the temperature of the S.I.M. during the 6 min laser acupuncture pen stimulus. When the laser acupuncture of both volunteers was conducted in the SI.3 point, it presented hyper-radiation of the hemi face in the same side, far from the application site. When this was applied in the SI.19 point, hyper-radiation in the same point and temperature lowering at the end of the meridian were observed. The laser energy caused thermal changes along the path of the S.I.M., distal, and proximal at the same time, proving the existence of the S.I.M.

  10. ImagingSIMS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2017-11-06

    ImagingSIMS is an open source application for loading, processing, manipulating and visualizing secondary ion mass spectrometry (SIMS) data. At PNNL, a separate branch has been further developed to incorporate application specific features for dynamic SIMS data sets. These include loading CAMECA IMS-1280, NanoSIMS and modified IMS-4f raw data, creating isotopic ratio images and stitching together images from adjacent interrogation regions. In addition to other modifications of the parent open source version, this version is equipped with a point-by-point image registration tool to assist with streamlining the image fusion process.

  11. Development of a TOF SIMS setup at the Zagreb heavy ion microbeam facility

    NASA Astrophysics Data System (ADS)

    Tadić, Tonči; Bogdanović Radović, Iva; Siketić, Zdravko; Cosic, Donny Domagoj; Skukan, Natko; Jakšić, Milko; Matsuo, Jiro

    2014-08-01

    We describe a new Time-of-flight Secondary Ion Mass Spectrometry (TOF SIMS) setup for MeV SIMS application, which is constructed and installed at the heavy ion microbeam facility at the Ruđer Bošković Institute in Zagreb. The TOF-SIMS setup is developed for high sensitivity molecular imaging using a heavy ion microbeam that focuses ion beams (from C to I) with sub-micron resolution. Dedicated pulse processing electronics for MeV SIMS application have been developed, enabling microbeam-scanning control, incoming ion microbeam pulsing and molecular mapping. The first results showing measured MeV SIMS spectra as well as molecular maps for samples of interest are presented and discussed.

  12. QCM-D and ToF-SIMS Investigation to Deconvolute the Relationship between Lipid Adsorption and Orientation on Lipase Activity.

    PubMed

    Joyce, Paul; Kempson, Ivan; Prestidge, Clive A

    2015-09-22

    Quartz crystal microbalance with dissipation (QCM-D) and time-of-flight secondary ion mass spectrometry (ToF-SIMS) were used to provide insights into the relationship between lipid adsorption kinetics and molecular behavior in porous silica particles of varying hydrophobicities on lipase activity. Lipase (an interfacial enzyme that cleaves ester bonds to break down lipids to fatty acids and monoglycerides) activity was controlled by loading triglycerides at different surface coverages in hydrophilic and hydrophobic porous silica particles. The rate of lipid adsorption increased 2-fold for the hydrophobic surface compared to the hydrophilic surface. However, for submonolayer lipid coverage, the hydrophilic surface enhanced lipase activity 4-fold, whereas the hydrophobic surface inhibited lipase activity 16-fold, compared to lipid droplets in water. A difference in lipid orientation for low surface coverage, evidenced by ToF-SIMS, indicated that lipid adsorbs to hydrophilic silica in a conformation promoting hydrolysis. Multilayer coverage on hydrophobic and hydrophilic surfaces was indistinguishable with ToF-SIMS analysis. Increased lipid adsorption for both substrates facilitated digestion kinetics comparable to a conventional emulsion. Improved understanding of the interfacial adsorption and orientation of lipid and its digestibility in porous silica has implications in improving the uptake of pharmaceuticals and nutrients from lipid-based delivery systems.

  13. Cross-correlating 2D and 3D galaxy surveys

    DOE PAGES

    Passaglia, Samuel; Manzotti, Alessandro; Dodelson, Scott

    2017-06-08

    Galaxy surveys probe both structure formation and the expansion rate, making them promising avenues for understanding the dark universe. Photometric surveys accurately map the 2D distribution of galaxy positions and shapes in a given redshift range, while spectroscopic surveys provide sparser 3D maps of the galaxy distribution. We present a way to analyse overlapping 2D and 3D maps jointly and without loss of information. We represent 3D maps using spherical Fourier-Bessel (sFB) modes, which preserve radial coverage while accounting for the spherical sky geometry, and we decompose 2D maps in a spherical harmonic basis. In these bases, a simple expression exists for the cross-correlation of the two fields. One very powerful application is the ability to simultaneously constrain the redshift distribution of the photometric sample, the sample biases, and cosmological parameters. We use our framework to show that combined analysis of DESI and LSST can improve cosmological constraints by factors ofmore » $${\\sim}1.2$$ to $${\\sim}1.8$$ on the region where they overlap relative to identically sized disjoint regions. We also show that in the overlap of DES and SDSS-III in Stripe 82, cross-correlating improves photo-$z$ parameter constraints by factors of $${\\sim}2$$ to $${\\sim}12$$ over internal photo-$z$ reconstructions.« less

  14. Micro-Vibration Performance Prediction of SEPTA24 Using SMeSim (RUAG Space Mechanism Simulator Tool)

    NASA Astrophysics Data System (ADS)

    Omiciuolo, Manolo; Lang, Andreas; Wismer, Stefan; Barth, Stephan; Szekely, Gerhard

    2013-09-01

    Scientific space missions are currently challenging the performances of their payloads. The performances can be dramatically restricted by micro-vibration loads generated by any moving parts of the satellites, thus by Solar Array Drive Assemblies too. Micro-vibration prediction of SADAs is therefore very important to support their design and optimization in the early stages of a programme. The Space Mechanism Simulator (SMeSim) tool, developed by RUAG, enhances the capability of analysing the micro-vibration emissivity of a Solar Array Drive Assembly (SADA) under a specified set of boundary conditions. The tool is developed in the Matlab/Simulink® environment throughout a library of blocks simulating the different components a SADA is made of. The modular architecture of the blocks, assembled by the user, and the set up of the boundary conditions allow time-domain and frequency-domain analyses of a rigid multi-body model with concentrated flexibilities and coupled- electronic control of the mechanism. SMeSim is used to model the SEPTA24 Solar Array Drive Mechanism and predict its micro-vibration emissivity. SMeSim and the return of experience earned throughout its development and use can now support activities like verification by analysis of micro-vibration emissivity requirements and/or design optimization to minimize the micro- vibration emissivity of a SADA.

  15. Improving SysSim's Planetary Occurrence Rate Estimates

    NASA Astrophysics Data System (ADS)

    Ashby, Keir; Ragozzine, Darin; Hsu, Danley; Ford, Eric B.

    2017-10-01

    Kepler's catalog of thousands of transiting planet candidates enables statistical characterization of the underlying planet occurrence rates as a function of period and radius. Due to geometric factors and general noise in measurements, we know that many planets--especially those with a small-radius and/or long-period--were not observed by Kepler.To account for Kepler's detection criteria, Hsu et al. 2017 expanded on work in Lissuaer et al. 2011 to develop the Planetary System Simulator or "SysSim". SysSim uses a forward model to generate simulated catalogs of exoplanet systems, determine which of those simulated planets would have been seen by Kepler in the presence of uncertainties, and then compares those “observed planets” to those actually seen by Kepler. It then uses Approximate Bayesian Computation to infer the posterior probability distributions of the input parameters used to generate the forward model. In Hsu et al. 2017, we focused on matching the observed frequency of planets by solving for the underlying occurrence rate for each bin in a 2-dimensional grid of radius and period. After summarizing the results of Hsu et al. 2017, we show new results that investigate the effect on occurrence rates from including more accurate completeness products (from the Kepler DR25 analysis) into SysSim.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hua, Xin; Yu, Xiao-Ying; Wang, Zhaoying

    The first results of using a novel single channel microfluidic reactor to enable Shewanella biofilm growth and in situ characterization using time-of-flight secondary ion mass spectrometry (ToF-SIMS) in the hydrated environment are presented. The new microfluidic interface allows direct probing of the liquid surface using ToF-SIMS, a vacuum surface technique. The detection window is an aperture of 2 m in diameter on a thin silicon nitride (SiN) membrane and it allows direct detection of the liquid surface. Surface tension of the liquid flowing inside the microchannel holds the liquid within the aperture. ToF-SIMS depth profiling was used to drill throughmore » the SiN membrane and the biofilm grown on the substrate. In situ 2D imaging of the biofilm in hydrated state was acquired, providing spatial distribution of the chemical compounds in the biofilm system. This data was compared with a medium filled microfluidic reactor devoid of biofilm and dried biofilm samples deposited on clean silicon wafers. Principle Component Analysis (PCA) was used to investigate these observations. Our results show that imaging biofilms in the hydrated environment using ToF-SIMS is possible using the unique microfluidic reactor. Moreover, characteristic biofilm fatty acids fragments were observed in the hydrated biofilm grown in the microfluidic channel, illustrating the advantage of imaging biofilm in its native environment.« less

  17. In Situ SIMS and IR Spectroscopy of Well-defined Surfaces Prepared by Soft Landing of Mass-selected Ions

    PubMed Central

    Johnson, Grant E.; Gunaratne, K. Don Dasitha; Laskin, Julia

    2014-01-01

    Soft landing of mass-selected ions onto surfaces is a powerful approach for the highly-controlled preparation of materials that are inaccessible using conventional synthesis techniques. Coupling soft landing with in situ characterization using secondary ion mass spectrometry (SIMS) and infrared reflection absorption spectroscopy (IRRAS) enables analysis of well-defined surfaces under clean vacuum conditions. The capabilities of three soft-landing instruments constructed in our laboratory are illustrated for the representative system of surface-bound organometallics prepared by soft landing of mass-selected ruthenium tris(bipyridine) dications, [Ru(bpy)3]2+ (bpy = bipyridine), onto carboxylic acid terminated self-assembled monolayer surfaces on gold (COOH-SAMs). In situ time-of-flight (TOF)-SIMS provides insight into the reactivity of the soft-landed ions. In addition, the kinetics of charge reduction, neutralization and desorption occurring on the COOH-SAM both during and after ion soft landing are studied using in situ Fourier transform ion cyclotron resonance (FT-ICR)-SIMS measurements. In situ IRRAS experiments provide insight into how the structure of organic ligands surrounding metal centers is perturbed through immobilization of organometallic ions on COOH-SAM surfaces by soft landing. Collectively, the three instruments provide complementary information about the chemical composition, reactivity and structure of well-defined species supported on surfaces. PMID:24961913

  18. In Situ SIMS and IR Spectroscopy of Well-Defined Surfaces Prepared by Soft Landing of Mass-Selected Ions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Grant E.; Gunaratne, Kalupathirannehelage Don D.; Laskin, Julia

    2014-06-16

    Soft landing of mass-selected ions onto surfaces is a powerful approach for the highly-controlled preparation of materials that are inaccessible using conventional synthesis techniques. Coupling soft landing with in situ characterization using secondary ion mass spectrometry (SIMS) and infrared reflection absorption spectroscopy (IRRAS) enables analysis of well-defined surfaces under clean vacuum conditions. The capabilities of three soft-landing instruments constructed in our laboratory are illustrated for the representative system of surface-bound organometallics prepared by soft landing of mass-selected ruthenium tris(bipyridine) dications, [Ru(bpy)3]2+, onto carboxylic acid terminated self-assembled monolayer surfaces on gold (COOH-SAMs). In situ time-of-flight (TOF)-SIMS provides insight into the reactivitymore » of the soft-landed ions. In addition, the kinetics of charge reduction, neutralization and desorption occurring on the COOH-SAM both during and after ion soft landing are studied using in situ Fourier transform ion cyclotron resonance (FT-ICR)-SIMS measurements. In situ IRRAS experiments provide insight into how the structure of organic ligands surrounding metal centers is perturbed through immobilization of organometallic ions on COOH-SAM surfaces by soft landing. Collectively, the three instruments provide complementary information about the chemical composition, reactivity and structure of well-defined species supported on surfaces.« less

  19. Cross-correlating 2D and 3D galaxy surveys

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Passaglia, Samuel; Manzotti, Alessandro; Dodelson, Scott

    Galaxy surveys probe both structure formation and the expansion rate, making them promising avenues for understanding the dark universe. Photometric surveys accurately map the 2D distribution of galaxy positions and shapes in a given redshift range, while spectroscopic surveys provide sparser 3D maps of the galaxy distribution. We present a way to analyse overlapping 2D and 3D maps jointly and without loss of information. We represent 3D maps using spherical Fourier-Bessel (sFB) modes, which preserve radial coverage while accounting for the spherical sky geometry, and we decompose 2D maps in a spherical harmonic basis. In these bases, a simple expression exists for the cross-correlation of the two fields. One very powerful application is the ability to simultaneously constrain the redshift distribution of the photometric sample, the sample biases, and cosmological parameters. We use our framework to show that combined analysis of DESI and LSST can improve cosmological constraints by factors ofmore » $${\\sim}1.2$$ to $${\\sim}1.8$$ on the region where they overlap relative to identically sized disjoint regions. We also show that in the overlap of DES and SDSS-III in Stripe 82, cross-correlating improves photo-$z$ parameter constraints by factors of $${\\sim}2$$ to $${\\sim}12$$ over internal photo-$z$ reconstructions.« less

  20. NREL's Water Power Software Makes a Splash; NREL Highlights, Research & Development, NREL (National Renewable Energy Laboratory)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2015-06-01

    WEC-Sim is a DOE-funded software tool being jointly developed by NREL and SNL. WEC-Sim computationally models wave energy converters (WEC), devices that generate electricity using movement of water systems such as oceans, rivers, etc. There is great potential for WECs to generate electricity, but as of yet, the industry has yet to establish a commercially viable concept. Modeling, design, and simulations tools are essential to the successful development of WECs. Commercial WEC modeling software tools can't be modified by the user. In contrast, WEC-Sim is a free, open-source, and flexible enough to be modified to meet the rapidly evolving needsmore » of the WEC industry. By modeling the power generation performance and dynamic loads of WEC designs, WEC-Sim can help support the development of new WEC devices by optimizing designs for cost of energy and competitiveness. By being easily accessible, WEC-Sim promises to help level the playing field in the WEC industry. Importantly, WEC-Sim is also excellent at its job! In 2014, WEC-Sim was used in conjunction with NREL’s FAST modeling software to win a hydrodynamic modeling competition. WEC-Sim and FAST performed very well at predicting the motion of a test device in comparison to other modeling tools. The most recent version of WEC-Sim (v1.1) was released in April 2015.« less

  1. Validation of the SimSET simulation package for modeling the Siemens Biograph mCT PET scanner

    NASA Astrophysics Data System (ADS)

    Poon, Jonathan K.; Dahlbom, Magnus L.; Casey, Michael E.; Qi, Jinyi; Cherry, Simon R.; Badawi, Ramsey D.

    2015-02-01

    Monte Carlo simulation provides a valuable tool in performance assessment and optimization of system design parameters for PET scanners. SimSET is a popular Monte Carlo simulation toolkit that features fast simulation time, as well as variance reduction tools to further enhance computational efficiency. However, SimSET has lacked the ability to simulate block detectors until its most recent release. Our goal is to validate new features of SimSET by developing a simulation model of the Siemens Biograph mCT PET scanner and comparing the results to a simulation model developed in the GATE simulation suite and to experimental results. We used the NEMA NU-2 2007 scatter fraction, count rates, and spatial resolution protocols to validate the SimSET simulation model and its new features. The SimSET model overestimated the experimental results of the count rate tests by 11-23% and the spatial resolution test by 13-28%, which is comparable to previous validation studies of other PET scanners in the literature. The difference between the SimSET and GATE simulation was approximately 4-8% for the count rate test and approximately 3-11% for the spatial resolution test. In terms of computational time, SimSET performed simulations approximately 11 times faster than GATE simulations. The new block detector model in SimSET offers a fast and reasonably accurate simulation toolkit for PET imaging applications.

  2. SimPhy: Phylogenomic Simulation of Gene, Locus, and Species Trees

    PubMed Central

    Mallo, Diego; De Oliveira Martins, Leonardo; Posada, David

    2016-01-01

    We present a fast and flexible software package—SimPhy—for the simulation of multiple gene families evolving under incomplete lineage sorting, gene duplication and loss, horizontal gene transfer—all three potentially leading to species tree/gene tree discordance—and gene conversion. SimPhy implements a hierarchical phylogenetic model in which the evolution of species, locus, and gene trees is governed by global and local parameters (e.g., genome-wide, species-specific, locus-specific), that can be fixed or be sampled from a priori statistical distributions. SimPhy also incorporates comprehensive models of substitution rate variation among lineages (uncorrelated relaxed clocks) and the capability of simulating partitioned nucleotide, codon, and protein multilocus sequence alignments under a plethora of substitution models using the program INDELible. We validate SimPhy's output using theoretical expectations and other programs, and show that it scales extremely well with complex models and/or large trees, being an order of magnitude faster than the most similar program (DLCoal-Sim). In addition, we demonstrate how SimPhy can be useful to understand interactions among different evolutionary processes, conducting a simulation study to characterize the systematic overestimation of the duplication time when using standard reconciliation methods. SimPhy is available at https://github.com/adamallo/SimPhy, where users can find the source code, precompiled executables, a detailed manual and example cases. PMID:26526427

  3. Identification, characterization and quantitation of pyrogenic polycylic aromatic hydrocarbons and other organic compounds in tire fire products.

    PubMed

    Wang, Zhendi; Li, K; Lambert, P; Yang, Chun

    2007-01-12

    On 15 August 2001, a tire fire took place at the Pneu Lavoie Facility in Gatineau, Quebec, in which 4000 to 6000 new and recycled tires were stored along with other potentially hazardous materials. Comprehensive gas chromatography-mass spectrometry (GC-MS) analyses were performed on the tire fire samples to facilitate detailed chemical composition characterization of toxic polycyclic aromatic hydrocarbons (PAHs) and other organic compounds in samples. It is found that significant amounts of PAHs, particularly the high-ring-number PAHs, were generated during the fire. In total, 165 PAH compounds including 13 isomers of molecular weight (MW) 302, 10 isomers of MW 278, 10 isomers of MW 276, 7 isomers of MW 252, 7 isomers of MW 228, and 8 isomers of MW 216 PAHs were positively identified in the tire fire wipe samples for the first time. Numerous S-, O-, and N-containing PAH compounds were also detected. The identification and characterization of the PAH isomers was mainly based on: (1) a positive match of mass spectral data of the PAH isomers with the NIST authentic mass spectra database; (2) a positive match of the GC retention indices (I) of PAHs with authentic standards and with those reported in the literature; (3) agreement of the PAH elution order with the NIST (US National Institute of Standards and Technology) Standard Reference Material 1597 for complex mixture of PAHs from coal tar; (4) a positive match of the distribution patterns of PAH isomers in the SIM mode between the tire fire samples and the NIST Standard Reference Materials and well-characterized reference oils. Quantitation of target PAHs was done on the GC-MS in the selected ion monitoring (SIM) mode using the internal standard method. The relative response factors (RRF) for target PAHs were obtained from analyses of authentic PAH standard compounds. Alkylated PAH homologues were quantitated using straight baseline integration of each level of alkylation.

  4. Static Time-of-Flight Secondary Ion Mass Spectrometry (SIMS) | Materials

    Science.gov Websites

    -Flight Secondary Ion Mass Spectrometry (SIMS) Image of high mass resolution and mass accuracy provided by TOF SIMS We used the high mass resolution and mass accuracy of TOF SIMS to study surface cleanliness acidic wash resulted in contamination by Fe and other metals. Without high mass accuracy, the CaO signal

  5. 78 FR 8587 - American Showa, Inc.; Blanchester Plant, Including On-Site Leased Workers From Adecco and Sims...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-06

    ....; Blanchester Plant, Including On-Site Leased Workers From Adecco and Sims Bros., Inc.; Blanchester, OH; Amended... workers from Sims Bros., Inc. were working on-site at the subject firm during the relevant period and that the services supplied by Sims Bros., Inc. were related to the production of gear boxes (and parts...

  6. Teaching the Teacher: Tutoring SimStudent Leads to More Effective Cognitive Tutor Authoring

    ERIC Educational Resources Information Center

    Matsuda, Noboru; Cohen, William W.; Koedinger, Kenneth R.

    2015-01-01

    SimStudent is a machine-learning agent initially developed to help novice authors to create cognitive tutors without heavy programming. Integrated into an existing suite of software tools called Cognitive Tutor Authoring Tools (CTAT), SimStudent helps authors to create an expert model for a cognitive tutor by tutoring SimStudent on how to solve…

  7. The accumulation pattern of ferruginol in the heartwood-forming Cryptomeria japonica xylem as determined by time-of-flight secondary ion mass spectrometry and quantity analysis

    PubMed Central

    Kuroda, Katsushi; Fujiwara, Takeshi; Hashida, Koh; Imai, Takanori; Kushi, Masayoshi; Saito, Kaori; Fukushima, Kazuhiko

    2014-01-01

    Background and Aims Heartwood formation is a unique phenomenon of tree species. Although the accumulation of heartwood substances is a well-known feature of the process, the accumulation mechanism remains unclear. The aim of this study was to determine the accumulation process of ferruginol, a predominant heartwood substance of Cryptomeria japonica, in heartwood-forming xylem. Methods The radial accumulation pattern of ferruginol was examined from sapwood and through the intermediate wood to the heartwood by direct mapping using time-of-flight secondary ion mass spectrometry (TOF-SIMS). The data were compared with quantitative results obtained from a novel method of gas chromatography analysis using laser microdissection sampling and with water distribution obtained from cryo-scanning electron microscopy. Key Results Ferruginol initially accumulated in the middle of the intermediate wood, in the earlywood near the annual ring boundary. It accumulated throughout the entire earlywood in the inner intermediate wood, and in both the earlywood and the latewood in the heartwood. The process of ferruginol accumulation continued for more than eight annual rings. Ferruginol concentration peaked at the border between the intermediate wood and heartwood, while the concentration was less in the latewood compared wiht the earlywood in each annual ring. Ferruginol tended to accumulate around the ray parenchyma cells. In addition, at the border between the intermediate wood and heartwood, the accumulation was higher in areas without water than in areas with water. Conclusions TOF-SIMS clearly revealed ferruginol distribution at the cellular level. Ferruginol accumulation begins in the middle of intermediate wood, initially in the earlywood near the annual ring boundary, then throughout the entire earlywood, and finally across to the whole annual ring in the heartwood. The heterogeneous timing of ferruginol accumulation could be related to the distribution of ray parenchyma cells and/or water in the heartwood-forming xylem. PMID:24651372

  8. The Combined Detection of Morphological and Molecular Biomarkers: Implications for Astrobiology

    NASA Technical Reports Server (NTRS)

    Toporski, J.; Steele, A.; Westall, F.; McKay, D. S.

    2001-01-01

    Experience gathered by previous researchers during their hunt for evidence of early Earth life has shown the complexity in interpreting observations of possible microfossils and to establish the evidence to be positive. Similarly, the stillsimmering controversy on the nature of the nano-structures in Martian meteorite ALH84001 described by McKay et al. (1996) emphasizes the difficulties of conclusively identifying those structures as (a) fossilized bacterial cells and (b) establish their indigeneity. A better understanding of biological signatures in rocks is needed in order to identify traces of microbial life, which include morphological, mineralogical and chemical traces. It is thus considered crucial to tackle the problems emerging in the search for evidence of early life on Earth and in exopaleontological research with a multidisciplinary approach. With this is mind we applied surface sensitive Time of Flight-Secondary Ion Mass Spectroscopy (ToF-SIMS) to a previously described 25 m.y. old fossil bacterial biofilm. This technique allows in situ analysis with high mass resolution as well as molecular imaging of micron sized structures. As no extraction or derivatisation of the sample is required for ToF-SIMS analysis, electron microscopical investigation of the same samples subsequent to analysis is possible, thus allowing the combination of molecular and morphological biomarkers. The analysed fossil bacterial biofilms were associated with macrofossils from volcanoclastic lacustrine sediments from the Upper Oligocene Enspel formation (Germany). Preliminary scanning electron microscopy (SEM) studies have shown that a fossil structure interpreted as a coprolite purely consisted of fossilized bacterial biofilm. For ToF-SIMS investigation small particles were taken from the fossil biofilm and mounted onto Au-coated In-foil and analysed in a Phi Evans T-2000 TRIFT system. The ToF-SIMS analysed samples were Au/Pd-sputter coated and imaged using a Philips XL40 Field Emission Gun SEM (FEG-SEM). ToF-SIMS analysis of the organic rich fossil biofilm (TOC 29%) in the 0-100 Dalton (Da) range showed significant amounts of inorganic species, confirming the results obtained previously by EDX analysis, clearly showing the bacterial fossils to be mineralised. ToF-SIMS furthermore revealed the presence of a variety of low- and high-mass organic molecules and fragments thereof. These include peaks indicative of alkenes and alkanes, aromatic organic species and the polycyclic aromatic hydrocarbon naphthalene. More tentatively, peaks indicative of alkyl pyrroles and pyridyl-CH2 were identified. Other peaks of interest include peaks indicative of C(n)H(2n)O2 and C(n)H(2n-2)O2, which according to their general formula would suggest the presence of both saturated and unsaturated fatty acids although further in situ derivatisation experiments and GC-MS (Gas Chromatography MS) need to be applied to verify this beyond doubt. Furthermore, peaks at m/z 370, 384, 398, 412, 426, 440, 454 and 468 were identified, which indicate the potential presence of bacterial hopanes, a class of biomarkers indicative of bacteria. The main diagnostic peak for this group of chemicals is the fragment at m/z 191.18. Our studies conducted on purified hopane standards have shown that in the high-mass resolution mode differentiation of this diagnostic hopane peak and polyethylene at m/z 191.05 is possible. However, the spectra discussed here were collected in the lower resolution mapping mode, therefore this differentiation was not possible. The centroids of the possible hopane peaks obtained on the fossil biofilms are well within the range associated with bacterial hopanes. There is a strong possibility therefore that hopanoids may be associated with the fossil bacterial cells. Due to the non-destructive nature of ToF-SIMS, analysed samples can be studied using SEM, thus allowing the combination of morphological and molecular biomarkers. Subsequent SEM analysis of the ToF-SIMS analysed samples confirmed that the analysed material purely consists of fossil bacterial cells. This is thus the first successful effort to demonstrate the combination of spectral and morphological biomarkers. The advantages of highly sensitive non-destructive in situ analysis techniques for biomarker detection are invaluable, particularly with respect to envisaged Mars sample return missions, as it may allow us to identify remains and traces of former microbial life in both ancient terrestrial and extraterrestrial materials. This technique may prove particularly useful in the quest for extraterrestrial life with respect to precious extraterrestrial materials, as minute quantities are sufficient to conduct analysis.

  9. CatSim: a new computer assisted tomography simulation environment

    NASA Astrophysics Data System (ADS)

    De Man, Bruno; Basu, Samit; Chandra, Naveen; Dunham, Bruce; Edic, Peter; Iatrou, Maria; McOlash, Scott; Sainath, Paavana; Shaughnessy, Charlie; Tower, Brendon; Williams, Eugene

    2007-03-01

    We present a new simulation environment for X-ray computed tomography, called CatSim. CatSim provides a research platform for GE researchers and collaborators to explore new reconstruction algorithms, CT architectures, and X-ray source or detector technologies. The main requirements for this simulator are accurate physics modeling, low computation times, and geometrical flexibility. CatSim allows simulating complex analytic phantoms, such as the FORBILD phantoms, including boxes, ellipsoids, elliptical cylinders, cones, and cut planes. CatSim incorporates polychromaticity, realistic quantum and electronic noise models, finite focal spot size and shape, finite detector cell size, detector cross-talk, detector lag or afterglow, bowtie filtration, finite detector efficiency, non-linear partial volume, scatter (variance-reduced Monte Carlo), and absorbed dose. We present an overview of CatSim along with a number of validation experiments.

  10. Space Interferometry Mission: Measuring the Universe

    NASA Technical Reports Server (NTRS)

    Marr, James; Dallas, Saterios; Laskin, Robert; Unwin, Stephen; Yu, Jeffrey

    1991-01-01

    The Space Interferometry Mission (SIM) will be the NASA Origins Program's first space based long baseline interferometric observatory. SIM will use a 10 m Michelson stellar interferometer to provide 4 microarcsecond precision absolute position measurements of stars down to 20th magnitude over its 5 yr. mission lifetime. SIM will also provide technology demonstrations of synthesis imaging and interferometric nulling. This paper describes the what, why and how of the SIM mission, including an overall mission and system description, science objectives, general description of how SIM makes its measurements, description of the design concepts now under consideration, operations concept, and supporting technology program.

  11. Fusing literature and full network data improves disease similarity computation.

    PubMed

    Li, Ping; Nie, Yaling; Yu, Jingkai

    2016-08-30

    Identifying relatedness among diseases could help deepen understanding for the underlying pathogenic mechanisms of diseases, and facilitate drug repositioning projects. A number of methods for computing disease similarity had been developed; however, none of them were designed to utilize information of the entire protein interaction network, using instead only those interactions involving disease causing genes. Most of previously published methods required gene-disease association data, unfortunately, many diseases still have very few or no associated genes, which impeded broad adoption of those methods. In this study, we propose a new method (MedNetSim) for computing disease similarity by integrating medical literature and protein interaction network. MedNetSim consists of a network-based method (NetSim), which employs the entire protein interaction network, and a MEDLINE-based method (MedSim), which computes disease similarity by mining the biomedical literature. Among function-based methods, NetSim achieved the best performance. Its average AUC (area under the receiver operating characteristic curve) reached 95.2 %. MedSim, whose performance was even comparable to some function-based methods, acquired the highest average AUC in all semantic-based methods. Integration of MedSim and NetSim (MedNetSim) further improved the average AUC to 96.4 %. We further studied the effectiveness of different data sources. It was found that quality of protein interaction data was more important than its volume. On the contrary, higher volume of gene-disease association data was more beneficial, even with a lower reliability. Utilizing higher volume of disease-related gene data further improved the average AUC of MedNetSim and NetSim to 97.5 % and 96.7 %, respectively. Integrating biomedical literature and protein interaction network can be an effective way to compute disease similarity. Lacking sufficient disease-related gene data, literature-based methods such as MedSim can be a great addition to function-based algorithms. It may be beneficial to steer more resources torward studying gene-disease associations and improving the quality of protein interaction data. Disease similarities can be computed using the proposed methods at http:// www.digintelli.com:8000/ .

  12. Phase 1 Validation Testing and Simulation for the WEC-Sim Open Source Code

    NASA Astrophysics Data System (ADS)

    Ruehl, K.; Michelen, C.; Gunawan, B.; Bosma, B.; Simmons, A.; Lomonaco, P.

    2015-12-01

    WEC-Sim is an open source code to model wave energy converters performance in operational waves, developed by Sandia and NREL and funded by the US DOE. The code is a time-domain modeling tool developed in MATLAB/SIMULINK using the multibody dynamics solver SimMechanics, and solves the WEC's governing equations of motion using the Cummins time-domain impulse response formulation in 6 degrees of freedom. The WEC-Sim code has undergone verification through code-to-code comparisons; however validation of the code has been limited to publicly available experimental data sets. While these data sets provide preliminary code validation, the experimental tests were not explicitly designed for code validation, and as a result are limited in their ability to validate the full functionality of the WEC-Sim code. Therefore, dedicated physical model tests for WEC-Sim validation have been performed. This presentation provides an overview of the WEC-Sim validation experimental wave tank tests performed at the Oregon State University's Directional Wave Basin at Hinsdale Wave Research Laboratory. Phase 1 of experimental testing was focused on device characterization and completed in Fall 2015. Phase 2 is focused on WEC performance and scheduled for Winter 2015/2016. These experimental tests were designed explicitly to validate the performance of WEC-Sim code, and its new feature additions. Upon completion, the WEC-Sim validation data set will be made publicly available to the wave energy community. For the physical model test, a controllable model of a floating wave energy converter has been designed and constructed. The instrumentation includes state-of-the-art devices to measure pressure fields, motions in 6 DOF, multi-axial load cells, torque transducers, position transducers, and encoders. The model also incorporates a fully programmable Power-Take-Off system which can be used to generate or absorb wave energy. Numerical simulations of the experiments using WEC-Sim will be presented. These simulations highlight the code features included in the latest release of WEC-Sim (v1.2), including: wave directionality, nonlinear hydrostatics and hydrodynamics, user-defined wave elevation time-series, state space radiation, and WEC-Sim compatibility with BEMIO (open source AQWA/WAMI/NEMOH coefficient parser).

  13. NanoSIMS opens a New Window for Deciphering Organic Matter in Terrestrial and Extraterrestrial Samples

    NASA Technical Reports Server (NTRS)

    Oehler, Dorothy ZS.; Robert, Francois; Mostefaoui, Smail; Meibom, Anders; Selo, Madeleine; McKay, David S.; Gibson, Everett K.

    2007-01-01

    Recognition of the earliest morphological or chemical evidence of terrestrial life has proved to be challenging, as organic matter in ancient rocks is commonly fragmentary and difficult to distinguish from abiotically-produced materials (Schopf, 1993; Van Zuilen et al., 2002; Altermann & Kazmierczak, 2003; Cady et al., 2003; Brasier et al., 2002, 2004, 2005; Hofmann, 2004; Skrzypczak et al., 2004, 2005). Yet, the ability to identify remnants of earliest life is critical to our understanding of the timing of life's origin on earth, the nature of earliest terrestrial life, and recognition of potential remnants of microbial life that might occur in extraterrestrial materials. The search for earliest life on Earth now extends to early Archean organic remains; these tend to be very poorly preserved and considerably more difficult to interpret than the delicately permineralized microfossils known from many Proterozoic deposits. Thus, recent efforts have been directed toward finding biosignatures that can help distinguish fragmentary remnants of ancient microbes from either pseudofossils or abiotic organic materials that may have formed hydrothermally or in extraterrestrial processes (House et al., 2000; Boyce et al., 2001; Kudryavtsev et al., 2001; Schopf, 2002; Schopf et al., 2002, 2005a,b; Cady et al., 2003; Garc a-Ruiz et al., 2003; Hofmann, 2004; Brasier et al., 2005; Rushdi and Simoneit, 2005; Skrzypczak et al., 2005). An exciting area of biosignature research involves the developing technology of NanoSIMS. NanoSIMS is secondary ion mass spectrometry (SIMS) for ultrafine feature, elemental and isotopic analysis. Its resolution approaches 0.05 micrometers for element mapping, which is 10-50 times finer than that attainable with conventional SIMS or electron microprobes. Consequently, NanoSIMS has the potential to reveal previously unknown, chemical and structural characteristics of organic matter preserved in geologic materials. Robert et al. (2005) were the first to combine NanoSIMS element maps with optical microscopic imagery in an effort to develop a new method for assessing biogenicity. They showed that the ability to simultaneously map the distribution of organic elements [such as carbon (C), nitrogen (N), and sulfur (S)] and compare those element distributions with optically recognizable, cellularly preserved fossils could provide significant new insights into the origin of organic materials in ancient sediments. This chapter details a recent NanoSIMS study which was designed to acquire new data relevant to establishing critical biosignatures (Oehler et al., 2006a-c). In this study, NanoSIMS was used to characterize element distributions of spheroidal and filamentous microfossils and associated organic laminae in chert from the approx. 0.85 billion year old (Ga) Bitter Springs Formation of Australia. Previous work established preservation of a diverse microbiota in the Bitter Springs Formation (Schopf, 1968; Schopf and Blacic, 1971), and there is no dispute within the scientific community regarding the biogenicity of any of the Bitter Springs structures evaluated in this new study. Thus, the NanoSIMS results described below provide new insight into - and can be used as a guide for assessing - the origin of less well understood organic materials that may occur in early Archean samples and in meteorites or other extraterrestrial samples.

  14. MS/MS analysis and imaging of lipids across Drosophila brain using secondary ion mass spectrometry.

    PubMed

    Phan, Nhu T N; Munem, Marwa; Ewing, Andrew G; Fletcher, John S

    2017-06-01

    Lipids are abundant biomolecules performing central roles to maintain proper functioning of cells and biological bodies. Due to their highly complex composition, it is critical to obtain information of lipid structures in order to identify particular lipids which are relevant for a biological process or metabolic pathway under study. Among currently available molecular identification techniques, MS/MS in secondary ion mass spectrometry (SIMS) imaging has been of high interest in the bioanalytical community as it allows visualization of intact molecules in biological samples as well as elucidation of their chemical structures. However, there have been few applications using SIMS and MS/MS owing to instrumental challenges for this capability. We performed MS and MS/MS imaging to study the lipid structures of Drosophila brain using the J105 and 40-keV Ar 4000 + gas cluster ion source, with the novelty being the use of MS/MS SIMS analysis of intact lipids in the fly brain. Glycerophospholipids were identified by MS/MS profiling. MS/MS was also used to characterize diglyceride fragment ions and to identify them as triacylglyceride fragments. Moreover, MS/MS imaging offers a unique possibility for detailed elucidation of biomolecular distribution with high accuracy based on the ion images of its fragments. This is particularly useful in the presence of interferences which disturb the interpretation of biomolecular localization. Graphical abstract MS/MS was performed during time-of-flight secondary ion mass spectrometry (ToF-SIMS) analysis of Drosophila melongaster (fruit fly) to elucidate the structure and origin of different chemical species in the brain including a range of different phospholipid classes (PC, PI, PE) and di- and triacylglycerides (DAG & TAG) species where reference MS/MS spectra provided a potential means of discriminating between the isobaric [M-OH] + ion of DAGs and the [M-RCO] + ion of TAGs.

  15. Identification of a novel cyanobacterial group as active diazotrophs in a coastal microbial mat using NanoSIMS analysis

    DOE PAGES

    Woebken, Dagmar; Burow, Luke C.; Prufert-Bebout, Leslie; ...

    2012-01-12

    N 2 fixation is a key process in photosynthetic microbial mats to support the nitrogen demands associated with primary production. Despite its importance, groups that actively fix N 2 and contribute to the input of organic N in these ecosystems still remain largely unclear. To investigate the active diazotrophic community in microbial mats from the Elkhorn Slough estuary, Monterey Bay, CA, USA, we conducted an extensive combined approach, including biogeochemical, molecular and high-resolution secondary ion mass spectrometry (NanoSIMS) analyses. Detailed analysis of dinitrogenase reductase (nifH) transcript clone libraries from mat samples that fixed N 2 at night indicated that cyanobacterialmore » nifH transcripts were abundant and formed a novel monophyletic lineage. Independent NanoSIMS analysis of 15N2-incubated samples revealed significant incorporation of 15N into small, non-heterocystous cyanobacterial filaments. Mat-derived enrichment cultures yielded a unicyanobacterial culture with similar filaments (named Elkhorn Slough Filamentous Cyanobacterium-1 (ESFC-1)) that contained nifH gene sequences grouping with the novel cyanobacterial lineage identified in the transcript clone libraries, displaying up to 100% amino-acid sequence identity. The 16S rRNA gene sequence recovered from this enrichment allowed for the identification of related sequences from Elkhorn Slough mats and revealed great sequence diversity in this cluster. Furthermore, by combining 15N 2 tracer experiments, fluorescence in situ hybridization and NanoSIMS, in situ N 2 fixation activity by the novel ESFC-1 group was demonstrated, suggesting that this group may be the most active cyanobacterial diazotroph in the Elkhorn Slough mat. Pyrotag sequences affiliated with ESFC-1 were recovered from mat samples throughout 2009, demonstrating the prevalence of this group. Here, this work illustrates that combining standard and single-cell analyses can link phylogeny and function to identify previously unknown key functional groups in complex ecosystems.« less

  16. FunSimMat: a comprehensive functional similarity database

    PubMed Central

    Schlicker, Andreas; Albrecht, Mario

    2008-01-01

    Functional similarity based on Gene Ontology (GO) annotation is used in diverse applications like gene clustering, gene expression data analysis, protein interaction prediction and evaluation. However, there exists no comprehensive resource of functional similarity values although such a database would facilitate the use of functional similarity measures in different applications. Here, we describe FunSimMat (Functional Similarity Matrix, http://funsimmat.bioinf.mpi-inf.mpg.de/), a large new database that provides several different semantic similarity measures for GO terms. It offers various precomputed functional similarity values for proteins contained in UniProtKB and for protein families in Pfam and SMART. The web interface allows users to efficiently perform both semantic similarity searches with GO terms and functional similarity searches with proteins or protein families. All results can be downloaded in tab-delimited files for use with other tools. An additional XML–RPC interface gives automatic online access to FunSimMat for programs and remote services. PMID:17932054

  17. The impact of detergents on the tissue decellularization process: a ToF-SIMS study

    PubMed Central

    White, Lisa J; Taylor, Adam J; Faulk, Denver M; Keane, Tim J; Saldin, Lindsey T; Reing, Janet E; Swinehart, Ilea T; Turner, Neill J; Ratner, Buddy D

    2017-01-01

    Biologic scaffolds are derived from mammalian tissues, which must be decellularized to remove cellular antigens that would otherwise incite an adverse immune response. Although widely used clinically, the optimum balance between cell removal and the disruption of matrix architecture and surface ligand landscape remains a considerable challenge. Here we describe the use of time of flight secondary ion mass spectroscopy (ToF-SIMS) to provide sensitive, molecular specific, localized analysis of detergent decellularized biologic scaffolds. We detected residual detergent fragments, specifically from Triton X-100, sodium deoxycholate and sodium dodecyl sulphate (SDS) in decellularized scaffolds; increased SDS concentrations from 0.1% to 1.0% increased both the intensity of SDS fragments and adverse cell outcomes. We also identified cellular remnants, by detecting phosphate and phosphocholine ions in PAA and CHAPS decellularized scaffolds. The present study demonstrates ToF-SIMS is not only a powerful tool for characterization of biologic scaffold surface molecular functionality, but also enables sensitive assessment of decellularization efficacy. PMID:27993639

  18. Error Modeling of Multibaseline Optical Truss: Part 1: Modeling of System Level Performance

    NASA Technical Reports Server (NTRS)

    Milman, Mark H.; Korechoff, R. E.; Zhang, L. D.

    2004-01-01

    Global astrometry is the measurement of stellar positions and motions. These are typically characterized by five parameters, including two position parameters, two proper motion parameters, and parallax. The Space Interferometry Mission (SIM) will derive these parameters for a grid of approximately 1300 stars covering the celestial sphere to an accuracy of approximately 4uas, representing a two orders of magnitude improvement over the most precise current star catalogues. Narrow angle astrometry will be performed to a 1uas accuracy. A wealth of scientific information will be obtained from these accurate measurements encompassing many aspects of both galactic (and extragalactic science. SIM will be subject to a number of instrument errors that can potentially degrade performance. Many of these errors are systematic in that they are relatively static and repeatable with respect to the time frame and direction of the observation. This paper and its companion define the modeling of the, contributing factors to these errors and the analysis of how they impact SIM's ability to perform astrometric science.

  19. Measurement of replication structures at the nanometer scale using super-resolution light microscopy

    PubMed Central

    Baddeley, D.; Chagin, V. O.; Schermelleh, L.; Martin, S.; Pombo, A.; Carlton, P. M.; Gahl, A.; Domaing, P.; Birk, U.; Leonhardt, H.; Cremer, C.; Cardoso, M. C.

    2010-01-01

    DNA replication, similar to other cellular processes, occurs within dynamic macromolecular structures. Any comprehensive understanding ultimately requires quantitative data to establish and test models of genome duplication. We used two different super-resolution light microscopy techniques to directly measure and compare the size and numbers of replication foci in mammalian cells. This analysis showed that replication foci vary in size from 210 nm down to 40 nm. Remarkably, spatially modulated illumination (SMI) and 3D-structured illumination microscopy (3D-SIM) both showed an average size of 125 nm that was conserved throughout S-phase and independent of the labeling method, suggesting a basic unit of genome duplication. Interestingly, the improved optical 3D resolution identified 3- to 5-fold more distinct replication foci than previously reported. These results show that optical nanoscopy techniques enable accurate measurements of cellular structures at a level previously achieved only by electron microscopy and highlight the possibility of high-throughput, multispectral 3D analyses. PMID:19864256

  20. Clinical Placement Before or After Simulated Learning Environments?: A Naturalistic Study of Clinical Skills Acquisition Among Early-Stage Paramedicine Students.

    PubMed

    Mills, Brennen W; Carter, Owen B J; Rudd, Cobie J; Ross, Nathan P; Claxton, Louise A

    2015-10-01

    There is conflicting evidence surrounding the merit of clinical placements (CPs) for early-stage health-profession students. Some contend that early-stage CPs facilitate contextualization of a subsequently learned theory. Others argue that training in simulated-learning experiences (SLEs) should occur before CP to ensure that students possess at least basic competency. We sought to investigate both claims. First-year paramedicine students (n = 85) undertook 3 days of CP and SLEs as part of course requirements. Students undertook CP either before or after participation in SLEs creating 2 groups (Clin → Sim/Sim → Clin). Clinical skills acquisition was measured via direct scenario-based clinical assessments with expert observers conducted at 4 intervals during the semester. Perceptions of difficulty of CP and SLE were measured via the National Aeronautics and Space Administration Task Load Index. Students' clinical assessment scores in both groups improved significantly from beginning to end of semester (P < 0.001). However, at semester's end, clinical assessment scores for the Sim → Clin group were statistically significantly greater than those of the Clin → Sim group (P = 0.021). Both groups found SLEs more demanding than CP (P < 0.001). However, compared with the Sim → Clin group, the Clin → Sim group rated SLE as substantially more time-demanding than CP (P = 0.003). Differences in temporal demand suggest that the Clin → Sim students had fewer opportunities to practice clinical skills during CP than the Sim → Clin students due to a more limited scope of practice. The Sim → Clin students contextualized SLE within subsequent CP resulting in greater improvement in clinical competency by semester's end in comparison with the Clin → Sim students who were forced to contextualize skills retrospectively.

  1. The eponymous Dr James Marion Sims MD, LLD (1813-1883).

    PubMed

    West, M J; Irvine, L M

    2015-02-01

    Dr James Marion Sims was born in 1813 in Lancaster County, South Carolina. It was while pioneering numerous surgical procedures in Alabama that in 1849 he achieved the outstanding landmark in medical history of successfully, and consistently, repairing vesicovaginal fistulae. Sims soon developed a reputation as a fine surgeon, with new operations and techniques, using novel surgical instruments and his innovative approaches frequently published. Moving to New York City in 1853, he further established hospitals devoted entirely to women's health. Sims was controversial, with flamboyant descriptions of self-confident success, yet they were tempered with sober reflection of failure and loss. Today we remain with the Sims speculum and Sims position, eponymous tributes to his accomplishments as the 'Father of Gynaecology'. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  2. WEC-SIM Phase 1 Validation Testing -- Numerical Modeling of Experiments: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruehl, Kelley; Michelen, Carlos; Bosma, Bret

    2016-08-01

    The Wave Energy Converter Simulator (WEC-Sim) is an open-source code jointly developed by Sandia National Laboratories and the National Renewable Energy Laboratory. It is used to model wave energy converters subjected to operational and extreme waves. In order for the WEC-Sim code to be beneficial to the wave energy community, code verification and physical model validation is necessary. This paper describes numerical modeling of the wave tank testing for the 1:33-scale experimental testing of the floating oscillating surge wave energy converter. The comparison between WEC-Sim and the Phase 1 experimental data set serves as code validation. This paper is amore » follow-up to the WEC-Sim paper on experimental testing, and describes the WEC-Sim numerical simulations for the floating oscillating surge wave energy converter.« less

  3. SimC7 Is a Novel NAD(P)H-Dependent Ketoreductase Essential for the Antibiotic Activity of the DNA Gyrase Inhibitor Simocyclinone.

    PubMed

    Schäfer, Martin; Le, Tung B K; Hearnshaw, Stephen J; Maxwell, Anthony; Challis, Gregory L; Wilkinson, Barrie; Buttner, Mark J

    2015-06-19

    Simocyclinone D8 (SD8) is a potent DNA gyrase inhibitor produced by Streptomyces antibioticus Tü6040. The simocyclinone (sim) biosynthetic gene cluster has been sequenced and a hypothetical biosynthetic pathway has been proposed. The tetraene linker in SD8 was suggested to be the product of a modular type I polyketide synthase working in trans with two monofunctional enzymes. One of these monofunctional enzymes, SimC7, was proposed to supply a dehydratase activity missing from two modules of the polyketide synthase. In this study, we report the function of SimC7. We isolated the entire ~72-kb sim cluster on a single phage artificial chromosome clone and produced simocyclinone heterologously in a Streptomyces coelicolor strain engineered for improved antibiotic production. Deletion of simC7 resulted in the production of a novel simocyclinone, 7-oxo-SD8, which unexpectedly carried a normal tetraene linker but was altered in the angucyclinone moiety. We demonstrate that SimC7 is an NAD(P)H-dependent ketoreductase that catalyzes the conversion of 7-oxo-SD8 into SD8. 7-oxo-SD8 was essentially inactive as a DNA gyrase inhibitor, and the reduction of the keto group by SimC7 was shown to be crucial for high-affinity binding to the enzyme. Thus, SimC7 is an angucyclinone ketoreductase that is essential for the biological activity of simocyclinone. Copyright © 2015. Published by Elsevier Ltd.

  4. The Evaluation Of Therapeutic Efficacy and Safety Profile of Simvastatin Prodrug Micelles in a Closed Fracture Mouse Model

    PubMed Central

    Zhang, Yijia; Jia, Zhenshan; Yuan, Hongjiang; Dusad, Anand; Ren, Ke; Wei, Xin; Fehringer, Edward V.; Purdue, P. Edward; Daluiski, Aaron; Goldring, Steven R.; Wang, Dong

    2016-01-01

    Purpose To evaluate the therapeutic efficiency of a micellar prodrug formulation of simvastatin (SIM/SIM-mPEG) and explore its safety in a closed femoral fracture mouse model. Methods The amphiphilic macromolecular prodrug of simvastatin (SIM-mPEG) was synthesized and formulated together with free simvastatin into micelles. It was also labeled with a near infrared dye for in vivo imaging purpose. A closed femoral fracture mouse model was established using a three-point bending device. The mice with established closed femoral fracture were treated with SIM/SIM-mPEG micelle, using free simvastatin and saline as controls. The therapeutic efficacy of the micelles was evaluated using a high-resolution micro-CT. Serum biochemistry and histology analyses were performed to explore the potential toxicity of the micelle formulation. Results Near Infrared Fluorescence (NIRF) imaging confirmed the passive targeting of SIM/SIM-mPEG micelles to the bone lesion of the mice with closed femoral fracture. The micelle was found to promote fracture healing with an excellent safety profile. In addition, the accelerated healing of the femoral fracture also helped to prevent disuse-associated same-side tibia bone loss accompanying the femur fracture. Conclusion SIM/SIM-mPEG micelle was found to be an effective and safe treatment for closed femoral fracture repair in mice. The evidence obtained in this study suggests that it may have the potential to be translated into a novel therapy for clinical management of skeletal fractures and non-union. PMID:27164897

  5. The motivation for special interests in individuals with autism and controls: Development and validation of the special interest motivation scale.

    PubMed

    Grove, Rachel; Roth, Ilona; Hoekstra, Rosa A

    2016-06-01

    Clinical observations and first person accounts of living with autism suggest that individuals with autism are highly motivated to engage in special interests, and that these interests remain important throughout life. Previous research assessing special interests has mainly focused on parental reports of children with autism spectrum conditions (ASC). To better understand the significance of and motivations for engaging in special interests it is essential to use self-report ratings. This paper aims to systematically explore the motivations for engagement in special interests, and whether these differ in adults with ASC, first-degree relatives and general population controls. The Special Interest Motivation Scale (SIMS) was developed to assess motivation to engage in special interests. The internal structure of this scale was evaluated using factor analysis, and mean scores on the SIMS factors were subsequently compared across individuals with autism, parents and general population controls. Factor analysis indicated a 20-item SIMS containing five factors assessing Personal life values and goals; Intrinsic interest and knowledge; Prestige; Engagement and "flow" and Achievement. Individuals with autism were more motivated by Intrinsic interest and knowledge and by Engagement and flow than controls. The 20-item SIMS is a quick to administer measure that provides a reliable description of motivation to engage in special interests. This study indicates that individuals with ASC are highly motivated to engage in their special interest, and are more motivated than controls by intrinsic motivational factors, some of which are associated with positive affect. This has implications for research and clinical practice. Autism Res 2016, 9: 677-688. © 2015 International Society for Autism Research, Wiley Periodicals, Inc. © 2015 International Society for Autism Research, Wiley Periodicals, Inc.

  6. Charge Retention by Organometallic Dications on Self-Assembled Monolayer Surfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laskin, Julia; Wang, Peng

    2014-05-15

    Charge retention by mass-selected ruthenium trisbipyridine dications, or Ru(bpy)32+, soft-landed onto self-assembled monolayer (SAM) surfaces of 1H, 1H, 2H, 2H-perfluorodecane-1-thiol (FSAM), 11-mercaptoundecanoic acid (COOH-SAM), and 11-amino-1-undecanethiol (HSAM) on gold was examined using in situ time-resolved secondary ion mass spectrometry in a Fourier transform ion cyclotron resonance apparatus (FT-ICR SIMS). FT-ICR SIMS analysis was performed during ion soft-landing and for 8–15 hours after the ion beam was switched off. Our results demonstrate efficient retention of the doubly charged precursor ion on the FSAM and COOH-SAM surfaces manifested by the abundant Ru(bpy)32+ ions in the SIMS spectra. In contrast, only the singlymore » charged Ru(bpy)3+ and Ru(bpy)2+ ions were observed on HSAM, indicating rapid loss of at least one charge by the deposited dications. The signal of Ru(bpy)32+ on COOH-SAM remained almost constant for more than 8 hours after the end of ion soft-landing, while a relatively fast decay followed by a plateau region was observed on the FSAM surface. However, we found that SIMS analysis of Ru(bpy)32+ ions soft-landed onto FSAM is complicated by facile ion-molecule reactivity occurring either on the surface or in the SIMS plume, making it difficult to accurately measure the charge reduction kinetics. Efficient retention of the doubly charged Ru(bpy)32+ ions on COOH-SAM is remarkably different from facile neutralization of protonated peptides deposited onto this surface reported in previous studies. Our results indicate different mechanisms of charge reduction of protonated molecules and permanent ions, such as Ru(bpy)32+, on SAM surfaces. Thus, we propose that proton loss is the major charge reduction channel for the protonated species, while electron transfer through the insulating SAM is responsible for the charge loss by permanent ions. Fundamental understanding of charge reduction phenomena is essential for controlled preparation of catalytically active substrates using ion soft-landing.« less

  7. The Formation and Early Evolution of a CME and the Associated Shock on 2014 January 8

    NASA Astrophysics Data System (ADS)

    Wan, Linfeng; Cheng, Xin; Shi, Tong; Su, Wei; Ding, Mingde

    2017-08-01

    We study the formation and early evolution of a limb coronal mass ejection (CME) and its associated shock wave that occurred on 2014 January 8. The extreme ultraviolet (EUV) images provided by AIA on board \\textit{Solar Dynamics Observatory} disclose that the CME first appears as a bubble-like structure. Subsequently, its expansion forms the CME and causes a quasi-circular EUV wave. Both the CME and the wave front are clearly visible at all of the AIA EUV passbands. Through a detailed kinematical analysis, it is found that the expansion of the CME undergoes two phases: a first phase with a strong but transient lateral over-expansion followed by a second phase with a self-similar expansion. The temporal evolution of the expansion velocity coincides very well with the variation of the 25--50 keV hard X-ray (HXR) flux of the associated flare, which indicates that magnetic reconnection most likely plays an important role in driving the expansion. Moreover, we find that, when the velocity of the CME reaches $\\sim$600 km s$^{-1}$, the EUV wave starts to evolve into a shock wave, which is evidenced by the appearance of a type II radio burst. Interestingly, we also notice an unusual solar radio signal at $\\sim$4 GHz that is similar to the pattern of a type II radio burst but drifts to higher frequencies at a rate of $\\sim$0.3 MHz per second during about 7 minutes. Its derived density is $\\sim$5$\\times$10$^{10}$ cm$^{-3}$ and increases slowly with time. Joint imaging observations of HXR and EUV help to locate the loop-top region and calculate its thermal proprieties, including slowly increasing densities ($\\sim$5$\\times$10$^{10}$ cm$^{-3}$) and temperatures ($\\sim$14 MK). The similar results obtained from two different ways above imply the possibility of this scenario: plasma blobs that are ejected along the current sheet via magnetic reconnection collide with underlying flare loops that are undergoing chromospheric evaporation. Finally, we also study the thermal properties of the CME and the EUV wave. We find that the plasma in the CME leading front and the wave front has a temperature of $\\sim$2 MK, while that in the CME core region and the flare region has a much higher temperature of $\\ge$8 MK.

  8. Effects of Preoperative Simulation on Minimally Invasive Hybrid Lumbar Interbody Fusion.

    PubMed

    Rieger, Bernhard; Jiang, Hongzhen; Reinshagen, Clemens; Molcanyi, Marek; Zivcak, Jozef; Grönemeyer, Dietrich; Bosche, Bert; Schackert, Gabriele; Ruess, Daniel

    2017-10-01

    The main focus of this study was to evaluate how preoperative simulation affects the surgical work flow, radiation exposure, and outcome of minimally invasive hybrid lumbar interbody fusion (MIS-HLIF). A total of 132 patients who underwent single-level MIS-HLIF were enrolled in a cohort study design. Dose area product was analyzed in addition to surgical data. Once preoperative simulation was established, 66 cases (SIM cohort) were compared with 66 patients who had previously undergone MIS-HLIF without preoperative simulation (NO-SIM cohort). Dose area product was reduced considerably in the SIM cohort (320 cGy·cm 2 NO-SIM cohort: 470 cGy·cm 2 ; P < 0.01). Surgical time was shorter for the SIM cohort (155 minutes; NO-SIM cohort, 182 minutes; P < 0.05). SIM cohort had a better outcome in Numeric Rating Scale back at 6 months follow-up compared with the NO-SIM cohort (P < 0.05). Preoperative simulation reduced radiation exposure and resulted in less back pain at the 6 months follow-up time point. Preoperative simulation provided guidance in determining the correct cage height. Outcome controls enabled the surgeon to improve the procedure and the software algorithm. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Why don't biologists use SIMS?. A critical evaluation of imaging MS

    NASA Astrophysics Data System (ADS)

    Heeren, R. M. A.; McDonnell, L. A.; Amstalden, E.; Luxembourg, S. L.; Altelaar, A. F. M.; Piersma, S. R.

    2006-07-01

    Secondary ion mass spectrometry is commonly used to study many different types of complex surfaces. Yet, compared with MALDI and ESI-MS, SIMS has not made a significant impact in biological or biomedical research. The key features of the technique, namely high spatial resolution, high detection efficiency of ions spanning a wide m/ z range, surface sensitivity and the high scan rates seem to match ideally with several questions posed at the cellular level. To this date, SIMS has had only limited success in the biological arena. Why is this and what is needed to change this? This discussion paper will critically review the advances and the usefulness of SIMS in biomedical research and compare it to other approaches that offer spatially resolved molecular information available to a researcher with a biological interest. We will demonstrate that the type of information generated by the various incarnations of SIMS is strongly dependent on sample preparation and surface condition and these phenomena are only poorly understood. Modern approaches such as the cluster gun developments, ME-SIMS, gold coating and MALDI stigmatic imaging on a SIMS instrument might change the perception of SIMS being a tool for semiconductor manufacturers and physicists, and might persuade biologists to use these innovative mass spectrometric imaging tools.

  10. Enumeration of total aerobic microorganisms in foods by SimPlate Total Plate Count-Color Indicator methods and conventional culture methods: collaborative study.

    PubMed

    Feldsine, Philip T; Leung, Stephanie C; Lienau, Andrew H; Mui, Linda A; Townsend, David E

    2003-01-01

    The relative efficacy of the SimPlate Total Plate Count-Color Indicator (TPC-CI) method (SimPlate 35 degrees C) was compared with the AOAC Official Method 966.23 (AOAC 35 degrees C) for enumeration of total aerobic microorganisms in foods. The SimPlate TPC-CI method, incubated at 30 degrees C (SimPlate 30 degrees C), was also compared with the International Organization for Standardization (ISO) 4833 method (ISO 30 degrees C). Six food types were analyzed: ground black pepper, flour, nut meats, frozen hamburger patties, frozen fruits, and fresh vegetables. All foods tested were naturally contaminated. Nineteen laboratories throughout North America and Europe participated in the study. Three method comparisons were conducted. In general, there was <0.3 mean log count difference in recovery among the SimPlate methods and their corresponding reference methods. Mean log counts between the 2 reference methods were also very similar. Repeatability (Sr) and reproducibility (SR) standard deviations were similar among the 3 method comparisons. The SimPlate method (35 degrees C) and the AOAC method were comparable for enumerating total aerobic microorganisms in foods. Similarly, the SimPlate method (30 degrees C) was comparable to the ISO method when samples were prepared and incubated according to the ISO method.

  11. Combination of structured illumination and single molecule localization microscopy in one setup

    NASA Astrophysics Data System (ADS)

    Rossberger, Sabrina; Best, Gerrit; Baddeley, David; Heintzmann, Rainer; Birk, Udo; Dithmar, Stefan; Cremer, Christoph

    2013-09-01

    Understanding the positional and structural aspects of biological nanostructures simultaneously is as much a challenge as a desideratum. In recent years, highly accurate (20 nm) positional information of optically isolated targets down to the nanometer range has been obtained using single molecule localization microscopy (SMLM), while highly resolved (100 nm) spatial information has been achieved using structured illumination microscopy (SIM). In this paper, we present a high-resolution fluorescence microscope setup which combines the advantages of SMLM with SIM in order to provide high-precision localization and structural information in a single setup. Furthermore, the combination of the wide-field SIM image with the SMLM data allows us to identify artifacts produced during the visualization process of SMLM data, and potentially also during the reconstruction process of SIM images. We describe the SMLM-SIM combo and software, and apply the instrument in a first proof-of-principle to the same region of H3K293 cells to achieve SIM images with high structural resolution (in the 100 nm range) in overlay with the highly accurate position information of localized single fluorophores. Thus, with its robust control software, efficient switching between the SMLM and SIM mode, fully automated and user-friendly acquisition and evaluation software, the SMLM-SIM combo is superior over existing solutions.

  12. Addressing Dual Patient and Staff Safety Through A Team-Based Standardized Patient Simulation for Agitation Management in the Emergency Department.

    PubMed

    Wong, Ambrose H; Auerbach, Marc A; Ruppel, Halley; Crispino, Lauren J; Rosenberg, Alana; Iennaco, Joanne D; Vaca, Federico E

    2018-06-01

    Emergency departments (EDs) have seen harm rise for both patients and health workers from an increasing rate of agitation events. Team effectiveness during care of this population is particularly challenging because fear of physical harm leads to competing interests. Simulation is frequently employed to improve teamwork in medical resuscitations but has not yet been reported to address team-based behavioral emergency care. As part of a larger investigation of agitated patient care, we designed this secondary study to examine the impact of an interprofessional standardized patient simulation for ED agitation management. We used a mixed-methods approach with emergency medicine resident and attending physicians, Physician Assistants (PAs) and Advanced Practice Registered Nurses (APRNs), ED nurses, technicians, and security officers at two hospital sites. After a simulated agitated patient encounter, we conducted uniprofessional and interprofessional focus groups. We undertook structured thematic analysis using a grounded theory approach. Quantitative data consisted of responses to the KidSIM Questionnaire addressing teamwork and simulation-based learning attitudes before and after each session. We reached data saturation with 57 participants. KidSIM scores revealed significant improvements in attitudes toward relevance of simulation, opportunities for interprofessional education, and situation awareness, as well as four of six questions for roles/responsibilities. Two broad themes emerged from the focus groups: (1) a team-based agitated patient simulation addressed dual safety of staff and patients simultaneously and (2) the experience fostered interprofessional discovery and cooperation in agitation management. A team-based simulated agitated patient encounter highlighted the need to consider the dual safety of staff and patients while facilitating interprofessional dialog and learning. Our findings suggest that simulation may be effective to enhance teamwork in behavioral emergency care.

  13. Practical routes to (SiH₃)₃P: applications in group IV semiconductor activation and in group III-V molecular synthesis.

    PubMed

    Tice, Jesse B; Chizmeshya, A V G; Tolle, J; D' Costa, V R; Menendez, J; Kouvetakis, J

    2010-05-21

    The (SiH₃)₃P hydride is introduced as a practical source for n-doping of group IV semiconductors and as a highly-reactive delivery agent of -(SiH₃)₂P functionalities in exploratory synthesis. In contrast to earlier methods, the compound is produced here in high purity quantitative yields via a new single-step method based on reactions of SiH₃Br and (Me₃Sn)₃P, circumventing the need for toxic and unstable starting materials. As an initial demonstration of its utility we synthesized monosubstituted Me₂M-P(SiH₃)₂ (M = Al, Ga, In) derivatives of Me₃M containing the (SiH₃)₂P ligand for the first time, in analogy to the known Me₂M-P(SiMe₃)₂ counterparts. A dimeric structure of Me₂M-P(SiH₃)₂ is proposed on the basis of spectroscopic characterizations and quantum chemical simulations. Next, in the context of materials synthesis, the (SiH₃)₃P compound was used to dope germanium for the first time by building a prototype p(++)Si(100)/i-Ge/n-Ge photodiode structure. The resultant n-type Ge layers contained active carrier concentrations of 3-4 × 10¹⁹ atoms cm⁻³ as determined by spectroscopic ellipsometry and confirmed by SIMS. Strain analysis using high resolution XRD yielded a Si content of 4 × 10²⁰ atoms cm⁻³ in agreement with SIMS and within the range expected for incorporating Si₃P type units into the diamond cubic Ge matrix. Extensive characterizations for structure, morphology and crystallinity indicate that the Si co-dopant plays essentially a passive role and does not compromise the device quality of the host material nor does it fundamentally alter its optical properties.

  14. Systems Engineering and Application of System Performance Modeling in SIM Lite Mission

    NASA Technical Reports Server (NTRS)

    Moshir, Mehrdad; Murphy, David W.; Milman, Mark H.; Meier, David L.

    2010-01-01

    The SIM Lite Astrometric Observatory will be the first space-based Michelson interferometer operating in the visible wavelength, with the ability to perform ultra-high precision astrometric measurements on distant celestial objects. SIM Lite data will address in a fundamental way questions such as characterization of Earth-mass planets around nearby stars. To accomplish these goals it is necessary to rely on a model-based systems engineering approach - much more so than most other space missions. This paper will describe in further detail the components of this end-to-end performance model, called "SIM-sim", and show how it has helped the systems engineering process.

  15. Numerical investigation of implementation of air-earth boundary by acoustic-elastic boundary approach

    USGS Publications Warehouse

    Xu, Y.; Xia, J.; Miller, R.D.

    2007-01-01

    The need for incorporating the traction-free condition at the air-earth boundary for finite-difference modeling of seismic wave propagation has been discussed widely. A new implementation has been developed for simulating elastic wave propagation in which the free-surface condition is replaced by an explicit acoustic-elastic boundary. Detailed comparisons of seismograms with different implementations for the air-earth boundary were undertaken using the (2,2) (the finite-difference operators are second order in time and space) and the (2,6) (second order in time and sixth order in space) standard staggered-grid (SSG) schemes. Methods used in these comparisons to define the air-earth boundary included the stress image method (SIM), the heterogeneous approach, the scheme of modifying material properties based on transversely isotropic medium approach, the acoustic-elastic boundary approach, and an analytical approach. The method proposed achieves the same or higher accuracy of modeled body waves relative to the SIM. Rayleigh waves calculated using the explicit acoustic-elastic boundary approach differ slightly from those calculated using the SIM. Numerical results indicate that when using the (2,2) SSG scheme for SIM and our new method, a spatial step of 16 points per minimum wavelength is sufficient to achieve 90% accuracy; 32 points per minimum wavelength achieves 95% accuracy in modeled Rayleigh waves. When using the (2,6) SSG scheme for the two methods, a spatial step of eight points per minimum wavelength achieves 95% accuracy in modeled Rayleigh waves. Our proposed method is physically reasonable and, based on dispersive analysis of simulated seismographs from a layered half-space model, is highly accurate. As a bonus, our proposed method is easy to program and slightly faster than the SIM. ?? 2007 Society of Exploration Geophysicists.

  16. Detecting feigned postconcussional and posttraumatic stress symptoms with the structured inventory of malingered symptomatology (SIMS).

    PubMed

    Parks, Adam C; Gfeller, Jeffrey; Emmert, Natalie; Lammert, Hannah

    2017-01-01

    The Structured Inventory of Malingered Symptomatology (SIMS) is a standalone symptom validity test (SVT) designed as a screening measure to detect a variety of exaggerated psychological symptoms. A number of studies have explored the accuracy of the SIMS in litigious and clinical populations, yet few have examined the validity of the SIMS in detecting feigned symptoms of postconcussional disorder (PCD) and posttraumatic stress disorder (PTSD). The present study examined the sensitivity of the SIMS in detecting undergraduate simulators (N = 78) feigning symptoms of PCD, PTSD, and the comorbid presentation of both PCD and PTSD symptomatologies. Overall, the SIMS Total score produced the highest sensitivities for the PCD symptoms and PCD+PTSD symptoms groups (.89 and .85, respectively), and to a lesser extent, the PTSD symptoms group (.69). The Affective Disorders (AF) subscale was most sensitive to the PTSD symptoms group compared to the PCD and PCD+PTSD symptoms groups. Additional sensitivity values are presented and examined at multiple scale cutoff scores. These findings support the use of the SIMS as a SVT screening measure for PCD and PTSD symptom exaggeration in neuropsychological assessment.

  17. Development and Validation of High Precision Thermal, Mechanical, and Optical Models for the Space Interferometry Mission

    NASA Technical Reports Server (NTRS)

    Lindensmith, Chris A.; Briggs, H. Clark; Beregovski, Yuri; Feria, V. Alfonso; Goullioud, Renaud; Gursel, Yekta; Hahn, Inseob; Kinsella, Gary; Orzewalla, Matthew; Phillips, Charles

    2006-01-01

    SIM Planetquest (SIM) is a large optical interferometer for making microarcsecond measurements of the positions of stars, and to detect Earth-sized planets around nearby stars. To achieve this precision, SIM requires stability of optical components to tens of picometers per hour. The combination of SIM s large size (9 meter baseline) and the high stability requirement makes it difficult and costly to measure all aspects of system performance on the ground. To reduce risks, costs and to allow for a design with fewer intermediate testing stages, the SIM project is developing an integrated thermal, mechanical and optical modeling process that will allow predictions of the system performance to be made at the required high precision. This modeling process uses commercial, off-the-shelf tools and has been validated against experimental results at the precision of the SIM performance requirements. This paper presents the description of the model development, some of the models, and their validation in the Thermo-Opto-Mechanical (TOM3) testbed which includes full scale brassboard optical components and the metrology to test them at the SIM performance requirement levels.

  18. Multiwavelength counterparts of the point sources in the Chandra Source Catalog

    NASA Astrophysics Data System (ADS)

    Reynolds, Michael; Civano, Francesca Maria; Fabbiano, Giuseppina; D'Abrusco, Raffaele

    2018-01-01

    The most recent release of the Chandra Source Catalog (CSC) version 2.0 comprises more than $\\sim$350,000 point sources, down to fluxes of $\\sim$10$^{-16}$ erg/cm$^2$/s, covering $\\sim$500 deg$^2$ of the sky, making it one of the best available X-ray catalogs to date. There are many reasons to have multiwavelength counterparts for sources, one such reason is that X-ray information alone is not enough to identify the sources and divide them between galactic and extragalactic origin, therefore multiwavelength data associated to each X-ray source is crucial for classification and scientific analysis of the sample. To perform this multiwavelength association, we are going to employ the recently released versatile tool NWAY (Salvato et al. 2017), based on a Bayesian algorithm for cross-matching multiple catalogs. NWAY allows the combination of multiple catalogs at the same time, provides a probability for the matches, even in case of non-detection due to different depth of the matching catalogs, and it can be used by including priors on the nature of the sources (e.g. colors, magnitudes, etc). In this poster, we are presenting the preliminary analysis using the CSC sources above the galactic plane matched to the WISE All-Sky catalog, SDSS, Pan-STARRS and GALEX.

  19. Alpha particle spectroscopy using FNTD and SIM super-resolution microscopy.

    PubMed

    Kouwenberg, J J M; Kremers, G J; Slotman, J A; Wolterbeek, H T; Houtsmuller, A B; Denkova, A G; Bos, A J J

    2018-06-01

    Structured illumination microscopy (SIM) for the imaging of alpha particle tracks in fluorescent nuclear track detectors (FNTD) was evaluated and compared to confocal laser scanning microscopy (CLSM). FNTDs were irradiated with an external alpha source and imaged using both methodologies. SIM imaging resulted in improved resolution, without increase in scan time. Alpha particle energy estimation based on the track length, direction and intensity produced results in good agreement with the expected alpha particle energy distribution. A pronounced difference was seen in the spatial scattering of alpha particles in the detectors, where SIM showed an almost 50% reduction compared to CLSM. The improved resolution of SIM allows for more detailed studies of the tracks induced by ionising particles. The combination of SIM and FNTDs for alpha radiation paves the way for affordable and fast alpha spectroscopy and dosimetry. © 2018 The Authors. Journal of Microscopy published by JohnWiley & Sons Ltd on behalf of Royal Microscopical Society.

  20. Visualization of metallodrugs in single cells by secondary ion mass spectrometry imaging.

    PubMed

    Wu, Kui; Jia, Feifei; Zheng, Wei; Luo, Qun; Zhao, Yao; Wang, Fuyi

    2017-07-01

    Secondary ion mass spectrometry, including nanoscale secondary ion mass spectrometry (NanoSIMS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS), has emerged as a powerful tool for biological imaging, especially for single cell imaging. SIMS imaging can provide information on subcellular distribution of endogenous and exogenous chemicals, including metallodrugs, from membrane through to cytoplasm and nucleus without labeling, and with high spatial resolution and chemical specificity. In this mini-review, we summarize recent progress in the field of SIMS imaging, particularly in the characterization of the subcellular distribution of metallodrugs. We anticipate that the SIMS imaging method will be widely applied to visualize subcellular distributions of drugs and drug candidates in single cells, exerting significant influence on early drug evaluation and metabolism in medicinal and pharmaceutical chemistry. Recent progress of SIMS applications in characterizing the subcellular distributions of metallodrugs was summarized.

  1. SimCell Status Board

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tanzman, Edward; Dactelides, John M; Sharp, Robert

    The Virtual SimCell is a method embodied in several software applications based on the Virtual Community Platform (VCP) (ANL-SF-11-049) and its Real-Time Dashboard (RTD) app. The purpose of this method is to more efficiently facilitate emergency preparedness exercises by allowing emergency preparedness exercise Simulation Cells -- SimCells -- to be established and managed through a computer network. SimCells take the place of organizations that would respond to actual emergencies, but are not participants in exercises of emergency preparedness plans. In effect, SimCells serve as actors portraying how those organizations would respond during real emergency events. The SimCell Status Board (SSB)more » is an RTD mini-app for controllers to communicate exercise events to players and each other by entering information into an integrated system of pre-defined data fields, displaying those data effectively, and preserving them for easy access during exercise evaluations.« less

  2. Stroboscopic Image Modulation to Reduce the Visual Blur of an Object Being Viewed by an Observer Experiencing Vibration

    NASA Technical Reports Server (NTRS)

    Kaiser, Mary K. (Inventor); Adelstein, Bernard D. (Inventor); Anderson, Mark R. (Inventor); Beutter, Brent R. (Inventor); Ahumada, Albert J., Jr. (Inventor); McCann, Robert S. (Inventor)

    2014-01-01

    A method and apparatus for reducing the visual blur of an object being viewed by an observer experiencing vibration. In various embodiments of the present invention, the visual blur is reduced through stroboscopic image modulation (SIM). A SIM device is operated in an alternating "on/off" temporal pattern according to a SIM drive signal (SDS) derived from the vibration being experienced by the observer. A SIM device (controlled by a SIM control system) operates according to the SDS serves to reduce visual blur by "freezing" (or reducing an image's motion to a slow drift) the visual image of the viewed object. In various embodiments, the SIM device is selected from the group consisting of illuminator(s), shutter(s), display control system(s), and combinations of the foregoing (including the use of multiple illuminators, shutters, and display control systems).

  3. uleSIMS characterization of silver reference surfaces

    NASA Astrophysics Data System (ADS)

    Palitsin, V. V.; Dowsett, M. G.; Mata, B. Guzmán de la; Oloff, I. W.; Gibbons, R.

    2006-07-01

    Ultra low energy SIMS (uleSIMS) is a high sensitivity analytical technique that is normally used for ultra shallow profiling at a depth resolution of up to1 nm. This work describes the use of uleSIMS as both a spectroscopic and depth-profiling tool for the characterization of the early stages of corrosion formed on reference surfaces of silver. These samples are being developed to help with the characterization of tarnished surfaces in a cultural heritage context, and uleSIMS enables the tarnishing to be studied from its very earliest stages due to its high sensitivity (ppm-ppb) and surface specificity. We show that, uleSIMS can be used effectively to study the surface chemistry and aid the development of reference surfaces themselves. In particular, handling contaminants, surface dust, and residues from polishing are relatively easy to identify allowing them to be separated from the parts of the mass spectrum specific to the early stages of corrosion.

  4. Nephron proximal tubule patterning and corpuscles of Stannius formation are regulated by the sim1a transcription factor and retinoic acid in zebrafish.

    PubMed

    Cheng, Christina N; Wingert, Rebecca A

    2015-03-01

    The mechanisms that establish nephron segments are poorly understood. The zebrafish embryonic kidney, or pronephros, is a simplified yet conserved genetic model to study this renal development process because its nephrons contain segments akin to other vertebrates, including the proximal convoluted and straight tubules (PCT, PST). The zebrafish pronephros is also associated with the corpuscles of Stannius (CS), endocrine glands that regulate calcium and phosphate homeostasis, but whose ontogeny from renal progenitors is largely mysterious. Initial patterning of zebrafish renal progenitors in the intermediate mesoderm (IM) involves the formation of rostral and caudal domains, the former being reliant on retinoic acid (RA) signaling, and the latter being repressed by elevated RA levels. Here, using expression profiling to gain new insights into nephrogenesis, we discovered that the gene single minded family bHLH transcription factor 1a (sim1a) is dynamically expressed in the renal progenitors-first marking the caudal domain, then becoming restricted to the proximal segments, and finally exhibiting specific CS expression. In loss of function studies, sim1a knockdown expanded the PCT and abrogated both the PST and CS populations. Conversely, overexpression of sim1a modestly expanded the PST and CS, while it reduced the PCT. These results show that sim1a activity is necessary and partially sufficient to induce PST and CS fates, and suggest that sim1a may inhibit PCT fate and/or negotiate the PCT/PST boundary. Interestingly, the sim1a expression domain in renal progenitors is responsive to altered levels of RA, suggesting that RA regulates sim1a, directly or indirectly, during nephrogenesis. sim1a deficient embryos treated with exogenous RA formed nephrons that were predominantly composed of PCT segments, but lacked the enlarged PST observed in RA treated wild-types, indicating that RA is not sufficient to rescue the PST in the absence of sim1a expression. Alternately, when sim1a knockdowns were exposed to the RA inhibitor diethylaminobenzaldehyde (DEAB), the CS was abrogated rather than expanded as seen in DEAB treated wild-types, revealing that CS formation in the absence of sim1a cannot be rescued by RA biosynthesis abrogation. Taken together, these data reveal previously unappreciated roles for sim1a in zebrafish pronephric proximal tubule and CS patterning, and are consistent with the model that sim1a acts downstream of RA to mitigate the formation of these lineages. These findings provide new insights into the genetic pathways that direct nephron development, and may have implications for understanding renal birth defects and kidney reprogramming. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.

  5. Correlative Microscopy Combining Secondary Ion Mass Spectrometry and Electron Microscopy: Comparison of Intensity-Hue-Saturation and Laplacian Pyramid Methods for Image Fusion.

    PubMed

    Vollnhals, Florian; Audinot, Jean-Nicolas; Wirtz, Tom; Mercier-Bonin, Muriel; Fourquaux, Isabelle; Schroeppel, Birgit; Kraushaar, Udo; Lev-Ram, Varda; Ellisman, Mark H; Eswara, Santhana

    2017-10-17

    Correlative microscopy combining various imaging modalities offers powerful insights into obtaining a comprehensive understanding of physical, chemical, and biological phenomena. In this article, we investigate two approaches for image fusion in the context of combining the inherently lower-resolution chemical images obtained using secondary ion mass spectrometry (SIMS) with the high-resolution ultrastructural images obtained using electron microscopy (EM). We evaluate the image fusion methods with three different case studies selected to broadly represent the typical samples in life science research: (i) histology (unlabeled tissue), (ii) nanotoxicology, and (iii) metabolism (isotopically labeled tissue). We show that the intensity-hue-saturation fusion method often applied for EM-sharpening can result in serious image artifacts, especially in cases where different contrast mechanisms interplay. Here, we introduce and demonstrate Laplacian pyramid fusion as a powerful and more robust alternative method for image fusion. Both physical and technical aspects of correlative image overlay and image fusion specific to SIMS-based correlative microscopy are discussed in detail alongside the advantages, limitations, and the potential artifacts. Quantitative metrics to evaluate the results of image fusion are also discussed.

  6. NanoSIMS study of trophic interactions in the coral-dinoflagellate endosymbiosis

    NASA Astrophysics Data System (ADS)

    Kopp, Christophe; Mathieu, Pernice; Domart-Coulon, Isabelle; Djediat, Chakib; Spangenberg, Jorge; Alexander, Duncan; Hignette, Michel; Meziane, Tarik; Meibom, Anders

    2013-04-01

    Tropical and subtropical reef-building corals generally form a stable endosymbiotic association with autotrophic single-celled dinoflagellate algae, commonly known as "zooxanthellae", which is crucial for the development of coral reef ecosystems. In the present work, the spatial and temporal dynamics of trophic interactions between corals and their dinoflagellates was investigated in situ and at a subcellular level in the reef-building coral Pocillopora damicornis. Transmission electron microscopy (TEM) and quantitative NanoSIMS isotopic imaging of tissue ultra-thin sections (70 nm) were combined to precisely track the assimilation and the fate of 15N-labeled compounds (ammonium, nitrate and aspartic acid) within each symbiotic partner of the coral-dinoflagellate association. Among our main results, we found that (i) both dinoflagellate algae and coral tissue rapidly assimilate ammonium and aspartic acid from the environment, (ii) however only the dinoflagellates assimilate nitrate, (ii) nitrogen is rapidly and temporary stored within the dinoflagellate cells into uric acid crystals, and (iii) the dinoflagellate endosymbionts translocate nitrogenous compounds to their coral host. This study paves the way for exploring in details the wide range of metabolic interactions between partners of any symbiosis in the biosphere.

  7. Project Status Update and SIM Science Breadth Discussion for the Origins Subcommittee (OS)

    NASA Technical Reports Server (NTRS)

    Marr, James C., IV; Shao, Mike

    2003-01-01

    This viewgraph presentation is composed of two sections The first reviews the features and the science goals of the Space Interferometry Mission (SIM). The goals are: (1) Perform a search for other planetary systems by surveying 2000 nearby stars for astrometric signatures of planetary companion, (2) Survey a sample of 200 nearby stars for orbiting planets down to terrestrial-type masses (3) Improve best current catalog of star positions by >lOOx and extend to fainter stars to allow extension of stellar knowledge to include our entire galaxy (4) Study dynamics and evolution of stars and star clusters in our galaxy to understand how our galaxy was formed and how it will evolve. (5) Calibrate luminosities of important stars and cosmological distance indicators to improve our understanding of stellar processes and to measure precise distance in the distant universe. The presentation also reviews the accomplishments since 2002, the plans for the subsequent 6 months. The second entitled "The Breadth of SIM Science," reviews SIM science goals in a larger context. SIM will serve to complement and pave the way for the Terrestrial Planet Finder (TPF). SIM observations of the motions of stars will tell us about the distribution of all gravitating mass (light plus dark matter) in the Galaxy. SIM observations of the motions of dwarf galaxies around our own will determine the mass distribution (light plus dark matter in the Halo. SIM will greatly extend these observations to test the theories of accretion disks around super massive black holes. SIM has advantages for studying AGN and other very compact objects.

  8. A Re-Engineered Software Interface and Workflow for the Open-Source SimVascular Cardiovascular Modeling Package.

    PubMed

    Lan, Hongzhi; Updegrove, Adam; Wilson, Nathan M; Maher, Gabriel D; Shadden, Shawn C; Marsden, Alison L

    2018-02-01

    Patient-specific simulation plays an important role in cardiovascular disease research, diagnosis, surgical planning and medical device design, as well as education in cardiovascular biomechanics. simvascular is an open-source software package encompassing an entire cardiovascular modeling and simulation pipeline from image segmentation, three-dimensional (3D) solid modeling, and mesh generation, to patient-specific simulation and analysis. SimVascular is widely used for cardiovascular basic science and clinical research as well as education, following increased adoption by users and development of a GATEWAY web portal to facilitate educational access. Initial efforts of the project focused on replacing commercial packages with open-source alternatives and adding increased functionality for multiscale modeling, fluid-structure interaction (FSI), and solid modeling operations. In this paper, we introduce a major SimVascular (SV) release that includes a new graphical user interface (GUI) designed to improve user experience. Additional improvements include enhanced data/project management, interactive tools to facilitate user interaction, new boundary condition (BC) functionality, plug-in mechanism to increase modularity, a new 3D segmentation tool, and new computer-aided design (CAD)-based solid modeling capabilities. Here, we focus on major changes to the software platform and outline features added in this new release. We also briefly describe our recent experiences using SimVascular in the classroom for bioengineering education.

  9. [Usefulness of SCL-90-R and SIMS inventories for the detection of mental health malingering at workplace].

    PubMed

    Loskin, Ulises E; Bertone, Matías S; López-Regueira, Joaquín

    2017-03-01

    Mental illness is a common cause of work leave. This situation has a negative impact on labor productivity and costs, and may contribute to con?icts affecting workplace environment. The purpose of this investigation is to describe the evaluation results of a total of 89 cases on sick leave for psychological and psychiatric reasons, and to test the convergent validity of scales in the "Positive Symptom Total" (PST) and "Positive Symptom Distress" (PSDI) of the Symptom Checklist Revised (SCL-90-R) by means of the Structured Inventory of Malingered Symptomatology (SIMS). Taking a score higher than 16 in the SIMS as the cut-off point, the analysis focused on whether PST and PSDI scales presented differences in average between malingers and non-malingers. From the total number of cases, 66 were found to be likely cases of malingered mental illness, with different averages in PST (77.02) and PSDI (2.71). Statistical correlation tests allowed to objectify convergent validity and statistical signifcance between the PSDI and PST scales of the inventory SCL-90-R and the SIMS inventory, with a higher average in PSDI scale (0.617) as compared with PST scale (0.413) in Spearman's rho. The results of the investigation confrm the usefulness of both instruments for the assessment of mental illness malingering in employers on sick leave due to mental disorders.

  10. Ontology- and graph-based similarity assessment in biological networks.

    PubMed

    Wang, Haiying; Zheng, Huiru; Azuaje, Francisco

    2010-10-15

    A standard systems-based approach to biomarker and drug target discovery consists of placing putative biomarkers in the context of a network of biological interactions, followed by different 'guilt-by-association' analyses. The latter is typically done based on network structural features. Here, an alternative analysis approach in which the networks are analyzed on a 'semantic similarity' space is reported. Such information is extracted from ontology-based functional annotations. We present SimTrek, a Cytoscape plugin for ontology-based similarity assessment in biological networks. http://rosalind.infj.ulst.ac.uk/SimTrek.html francisco.azuaje@crp-sante.lu Supplementary data are available at Bioinformatics online.

  11. Simultaneous 99mtc/111in spect reconstruction using accelerated convolution-based forced detection monte carlo

    NASA Astrophysics Data System (ADS)

    Karamat, Muhammad I.; Farncombe, Troy H.

    2015-10-01

    Simultaneous multi-isotope Single Photon Emission Computed Tomography (SPECT) imaging has a number of applications in cardiac, brain, and cancer imaging. The major concern however, is the significant crosstalk contamination due to photon scatter between the different isotopes. The current study focuses on a method of crosstalk compensation between two isotopes in simultaneous dual isotope SPECT acquisition applied to cancer imaging using 99mTc and 111In. We have developed an iterative image reconstruction technique that simulates the photon down-scatter from one isotope into the acquisition window of a second isotope. Our approach uses an accelerated Monte Carlo (MC) technique for the forward projection step in an iterative reconstruction algorithm. The MC estimated scatter contamination of a radionuclide contained in a given projection view is then used to compensate for the photon contamination in the acquisition window of other nuclide. We use a modified ordered subset-expectation maximization (OS-EM) algorithm named simultaneous ordered subset-expectation maximization (Sim-OSEM), to perform this step. We have undertaken a number of simulation tests and phantom studies to verify this approach. The proposed reconstruction technique was also evaluated by reconstruction of experimentally acquired phantom data. Reconstruction using Sim-OSEM showed very promising results in terms of contrast recovery and uniformity of object background compared to alternative reconstruction methods implementing alternative scatter correction schemes (i.e., triple energy window or separately acquired projection data). In this study the evaluation is based on the quality of reconstructed images and activity estimated using Sim-OSEM. In order to quantitate the possible improvement in spatial resolution and signal to noise ratio (SNR) observed in this study, further simulation and experimental studies are required.

  12. Determination of 1-chloro-4-[2,2,2-trichloro-1-(4-chlorophenyl)ethyl]benzene and related compounds in marine pore water by automated thermal desorption-gas chromatography/mass spectrometry using disposable optical fiber

    USGS Publications Warehouse

    Eganhouse, Robert P.; DiFilippo, Erica L

    2015-01-01

    A method is described for determination of ten DDT-related compounds in marine pore water based on equilibrium solid-phase microextraction (SPME) using commercial polydimethylsiloxane-coated optical fiber with analysis by automated thermal desorption-gas chromatography/mass spectrometry (TD-GC/MS). Thermally cleaned fiber was directly exposed to sediments and allowed to reach equilibrium under static conditions at the in situ field temperature. Following removal, fibers were rinsed, dried and cut into appropriate lengths for storage in leak-tight containers at -20°C. Analysis by TD-GC/MS under full scan (FS) and selected ion monitoring (SIM) modes was then performed. Pore-water method detection limits in FS and SIM modes were estimated at 0.05-2.4ng/L and 0.7-16pg/L, respectively. Precision of the method, including contributions from fiber handling, was less than 10%. Analysis of independently prepared solutions containing eight DDT compounds yielded concentrations that were within 6.9±5.5% and 0.1±14% of the actual concentrations in FS and SIM modes, respectively. The use of optical fiber with automated analysis allows for studies at high temporal and/or spatial resolution as well as for monitoring programs over large spatial and/or long temporal scales with adequate sample replication. This greatly enhances the flexibility of the technique and improves the ability to meet quality control objectives at significantly lower cost.

  13. Artist concept of SIM PlanetQuest Artist Concept

    NASA Image and Video Library

    2002-12-21

    Artist's concept of the current mission configuration. SIM PlanetQuest (formerly called Space Interferometry Mission), currently under development, will determine the positions and distances of stars several hundred times more accurately than any previous program. This accuracy will allow SIM to determine the distances to stars throughout the galaxy and to probe nearby stars for Earth-sized planets. SIM will open a window to a new world of discoveries. http://photojournal.jpl.nasa.gov/catalog/PIA04248

  14. Transfer of skills on LapSim virtual reality laparoscopic simulator into the operating room in urology.

    PubMed

    Alwaal, Amjad; Al-Qaoud, Talal M; Haddad, Richard L; Alzahrani, Tarek M; Delisle, Josee; Anidjar, Maurice

    2015-01-01

    Assessing the predictive validity of the LapSim simulator within a urology residency program. Twelve urology residents at McGill University were enrolled in the study between June 2008 and December 2011. The residents had weekly training on the LapSim that consisted of 3 tasks (cutting, clip-applying, and lifting and grasping). They underwent monthly assessment of their LapSim performance using total time, tissue damage and path length among other parameters as surrogates for their economy of movement and respect for tissue. The last residents' LapSim performance was compared with their first performance of radical nephrectomy on anesthetized porcine models in their 4(th) year of training. Two independent urologic surgeons rated the resident performance on the porcine models, and kappa test with standardized weight function was used to assess for inter-observer bias. Nonparametric spearman correlation test was used to compare each rater's cumulative score with the cumulative score obtained on the porcine models in order to test the predictive validity of the LapSim simulator. The kappa results demonstrated acceptable agreement between the two observers among all domains of the rating scale of performance except for confidence of movement and efficiency. In addition, poor predictive validity of the LapSim simulator was demonstrated. Predictive validity was not demonstrated for the LapSim simulator in the context of a urology residency training program.

  15. A Virtual Research Environment for a Secondary Ion Mass Spectrometer (SIMS)

    NASA Astrophysics Data System (ADS)

    Wiedenbeck, M.; Schäfer, L.; Klump, J.; Galkin, A.

    2013-12-01

    Overview: This poster describes the development of a Virtual Research Environment for the Secondary Ion Mass Spectrometer (SIMS) at GFZ Potsdam. Background: Secondary Ion Mass Spectrometers (SIMS) are extremely sensitive instruments for analyzing the surfaces of solid and thin film samples. These instruments are rare, expensive and experienced operators are very highly sought after. As such, measurement time is a precious commodity, until now only accessible to small numbers of researchers. The challenge: The Virtual SIMS Project aims to set up a Virtual Research Environment for the operation of the CAMECA IMS 1280-HR instrument at the GFZ Potsdam. The objective of the VRE is to provide SIMS access not only to researchers locally present in Potsdam but also to scientists working with SIMS cooperation partners in e.g., South Africa, Brazil or India. The requirements: The system should address the complete spectrum of laboratory procedures - from online application for measurement time, to remote access for data acquisition to data archiving for the subsequent publication and for future reuse. The approach: The targeted Virtual SIMS Environment will consist of a: 1. Web Server running the Virtual SIMS website providing general information about the project, lab access proposal forms and calendar for the timing of project related tasks. 2. LIMS Server, responsible for scheduling procedures, data management and, if applicable, accounting and billing. 3. Remote SIMS Tool, devoted to the operation of the experiment within a remote control environment. 4. Publishing System, which supports the publication of results in cooperation with the GFZ Library services. 5. Training Simulator, which offers the opportunity to rehearse experiments and to prepare for possible events such as a power outages or interruptions to broadband services. First results: The SIMS Virtual Research Environment will be mainly based on open source software, the only exception being the CAMECA IMS 1280-HR SIMS operating under LabView. The Publishing System will be based on eSciDoc, which is already successfully used by the GFZ scientific library. For the LIMS Server we are currently testing various options. The challenge, however, is the successful integration of all the various components and, where necessary, the definition of useful interfaces between the modules.

  16. Improved Response to Disasters and Outbreaks by Tracking Population Movements with Mobile Phone Network Data: A Post-Earthquake Geospatial Study in Haiti

    PubMed Central

    Bengtsson, Linus; Lu, Xin; Thorson, Anna; Garfield, Richard; von Schreeb, Johan

    2011-01-01

    Background Population movements following disasters can cause important increases in morbidity and mortality. Without knowledge of the locations of affected people, relief assistance is compromised. No rapid and accurate method exists to track population movements after disasters. We used position data of subscriber identity module (SIM) cards from the largest mobile phone company in Haiti (Digicel) to estimate the magnitude and trends of population movements following the Haiti 2010 earthquake and cholera outbreak. Methods and Findings Geographic positions of SIM cards were determined by the location of the mobile phone tower through which each SIM card connects when calling. We followed daily positions of SIM cards 42 days before the earthquake and 158 days after. To exclude inactivated SIM cards, we included only the 1.9 million SIM cards that made at least one call both pre-earthquake and during the last month of study. In Port-au-Prince there were 3.2 persons per included SIM card. We used this ratio to extrapolate from the number of moving SIM cards to the number of moving persons. Cholera outbreak analyses covered 8 days and tracked 138,560 SIM cards. An estimated 630,000 persons (197,484 Digicel SIM cards), present in Port-au-Prince on the day of the earthquake, had left 19 days post-earthquake. Estimated net outflow of people (outflow minus inflow) corresponded to 20% of the Port-au-Prince pre-earthquake population. Geographic distribution of population movements from Port-au-Prince corresponded well with results from a large retrospective, population-based UN survey. To demonstrate feasibility of rapid estimates and to identify areas at potentially increased risk of outbreaks, we produced reports on SIM card movements from a cholera outbreak area at its immediate onset and within 12 hours of receiving data. Conclusions Results suggest that estimates of population movements during disasters and outbreaks can be delivered rapidly and with potentially high validity in areas with high mobile phone use. Please see later in the article for the Editors' Summary PMID:21918643

  17. HexSim: a modeling environment for ecology and conservation.

    EPA Science Inventory

    HexSim is a powerful and flexible new spatially-explicit, individual based modeling environment intended for use in ecology, conservation, genetics, epidemiology, toxicology, and other disciplines. We describe HexSim, illustrate past applications that contributed to our >10 year ...

  18. An Acute Butyr-Fentanyl Fatality: A Case Report with Postmortem Concentrations.

    PubMed

    McIntyre, Iain M; Trochta, Amber; Gary, Ray D; Wright, Jennifer; Mena, Othon

    2016-03-01

    In this case report, we present an evaluation of the distribution of postmortem concentrations of butyr-fentanyl in a fatality attributed principally to the drug. A man who had a history of intravenous drug abuse was found unresponsive on the bathroom floor of his home. Drug paraphernalia was located on the bathroom counter. Toxicology testing, which initially screened positive for fentanyl by enzyme-linked immunosorbent assay, subsequently confirmed butyr-fentanyl, which was then quantitated by gas chromatography-mass spectrometry-specific ion monitoring (GC-MS SIM) analysis following liquid-liquid extraction. The butyr-fentanyl peripheral blood concentration was quantitated at 58 ng/mL compared with the central blood concentration of 97 ng/mL. The liver concentration was 320 ng/g, the vitreous was 40 ng/mL, the urine was 670 ng/mL and the gastric contained 170 mg. Acetyl-fentanyl was also detected in all biological specimens tested. Peripheral blood concentration was quantitated at 38 ng/mL compared with the central blood concentration of 32 ng/mL. The liver concentration was 110 ng/g, the vitreous was 38 ng/mL, the urine was 540 ng/mL and the gastric contained <70 mg. The only other drug detected was a relatively low concentration of benzoylecgonine. The cause of death was certified as acute butyr-fentanyl, acetyl-fentanyl and cocaine intoxication, and the manner of death was certified as accident. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. SIM PlanetQuest: Science with the Space Interferometry Mission

    NASA Technical Reports Server (NTRS)

    Unwin, Stephen (Editor); Turyshev, Slava (Editor)

    2004-01-01

    SIM - the Space Interferometry Mission - will perform precision optical astrometry on objects as faint as R magnitude 20. It will be the first space-based astrometric interferometer, operating in the optical band with a 10-m baseline. The Project is managed by the Jet Propulsion Laboratory, California Institute of Technology, in close collaboration with two industry partners, Lockheed Martin Missiles and Space, and TRW Inc., Space and Electronics Group. Launch of SIM is currently planned for 2009. In its wide-angle astrometric mode, SIM will yield 4 microarcsecond absolute position and parallax measurements. Astrometric planet searches will be done in a narrow-angle mode, with an accuracy of 4 microarcseconds or better in a single measurement. As a pointed rather than a survey instrument, SIM will maintain.its astrometric accuracy down to the faintest, magnitudes, opening up the opportunity for astrometry of active galactic nuclei to better than 10 pas. SIM will define a new astrometric reference frame, using a grid of approximately 1500 stars with positions accurate to 4 microarcseconds. The SIM Science Team comprises the Principal Investigators of ten Key Projects, and five Mission Scientists contributing their expertise to specific areas of the mission. Their science programs cover a wide range of topics in Galactic and extragalactic astronomy. They include: searches for low-mass planets - including analogs to our own solar system - tlie formation and dynamics of our Galaxy, calibration of the cosmic distance scale, and fundamental stellar astrophysics. All of the science observing on SIM is competitively awarded; the Science Team programs total about 40% of the total available, and the remainder will be assigned via future NASA competitions. This report is a compilation of science summaries by members of the Science Team, and it illustrates the wealth of scientific problems that microarcsecond-precision astrometry can contribute to. More information on SIM, including copies of this report, may be obtained from the project web site, at http://sim. jpl.nasa.gov.

  20. Bio-SimVerb and Bio-SimLex: wide-coverage evaluation sets of word similarity in biomedicine.

    PubMed

    Chiu, Billy; Pyysalo, Sampo; Vulić, Ivan; Korhonen, Anna

    2018-02-05

    Word representations support a variety of Natural Language Processing (NLP) tasks. The quality of these representations is typically assessed by comparing the distances in the induced vector spaces against human similarity judgements. Whereas comprehensive evaluation resources have recently been developed for the general domain, similar resources for biomedicine currently suffer from the lack of coverage, both in terms of word types included and with respect to the semantic distinctions. Notably, verbs have been excluded, although they are essential for the interpretation of biomedical language. Further, current resources do not discern between semantic similarity and semantic relatedness, although this has been proven as an important predictor of the usefulness of word representations and their performance in downstream applications. We present two novel comprehensive resources targeting the evaluation of word representations in biomedicine. These resources, Bio-SimVerb and Bio-SimLex, address the previously mentioned problems, and can be used for evaluations of verb and noun representations respectively. In our experiments, we have computed the Pearson's correlation between performances on intrinsic and extrinsic tasks using twelve popular state-of-the-art representation models (e.g. word2vec models). The intrinsic-extrinsic correlations using our datasets are notably higher than with previous intrinsic evaluation benchmarks such as UMNSRS and MayoSRS. In addition, when evaluating representation models for their abilities to capture verb and noun semantics individually, we show a considerable variation between performances across all models. Bio-SimVerb and Bio-SimLex enable intrinsic evaluation of word representations. This evaluation can serve as a predictor of performance on various downstream tasks in the biomedical domain. The results on Bio-SimVerb and Bio-SimLex using standard word representation models highlight the importance of developing dedicated evaluation resources for NLP in biomedicine for particular word classes (e.g. verbs). These are needed to identify the most accurate methods for learning class-specific representations. Bio-SimVerb and Bio-SimLex are publicly available.

  1. The medical ethics of Dr J Marion Sims: a fresh look at the historical record

    PubMed Central

    Wall, L L

    2006-01-01

    Vesicovaginal fistula was a catastrophic complication of childbirth among 19th century American women. The first consistently successful operation for this condition was developed by Dr J Marion Sims, an Alabama surgeon who carried out a series of experimental operations on black slave women between 1845 and 1849. Numerous modern authors have attacked Sims's medical ethics, arguing that he manipulated the institution of slavery to perform ethically unacceptable human experiments on powerless, unconsenting women. This article reviews these allegations using primary historical source material and concludes that the charges that have been made against Sims are largely without merit. Sims's modern critics have discounted the enormous suffering experienced by fistula victims, have ignored the controversies that surrounded the introduction of anaesthesia into surgical practice in the middle of the 19th century, and have consistently misrepresented the historical record in their attacks on Sims. Although enslaved African American women certainly represented a “vulnerable population” in the 19th century American South, the evidence suggests that Sims's original patients were willing participants in his surgical attempts to cure their affliction—a condition for which no other viable therapy existed at that time. PMID:16731734

  2. A NASP (N1/N2)-Related Protein, Sim3, Binds CENP-A and Is Required for Its Deposition at Fission Yeast Centromeres

    PubMed Central

    Dunleavy, Elaine M.; Pidoux, Alison L.; Monet, Marie; Bonilla, Carolina; Richardson, William; Hamilton, Georgina L.; Ekwall, Karl; McLaughlin, Paul J.; Allshire, Robin C.

    2007-01-01

    Summary A defining feature of centromeres is the presence of the histone H3 variant CENP-ACnp1. It is not known how CENP-ACnp1 is specifically delivered to, and assembled into, centromeric chromatin. Through a screen for factors involved in kinetochore integrity in fission yeast, we identified Sim3. Sim3 is homologous to known histone binding proteins NASPHuman and N1/N2Xenopus and aligns with Hif1S. cerevisiae, defining the SHNi-TPR family. Sim3 is distributed throughout the nucleoplasm, yet it associates with CENP-ACnp1 and also binds H3. Cells defective in Sim3 function have reduced levels of CENP-ACnp1 at centromeres (and increased H3) and display chromosome segregation defects. Sim3 is required to allow newly synthesized CENP-ACnp1 to accumulate at centromeres in S and G2 phase-arrested cells in a replication-independent mechanism. We propose that one function of Sim3 is to act as an escort that hands off CENP-ACnp1 to chromatin assembly factors, allowing its incorporation into centromeric chromatin. PMID:18158900

  3. GLABROUS INFLORESCENCE STEMS regulates trichome branching by genetically interacting with SIM in Arabidopsis.

    PubMed

    Sun, Li-Li; Zhou, Zhong-Jing; An, Li-Jun; An, Yan; Zhao, Yong-Qin; Meng, Xiao-Fang; Steele-King, Clare; Gan, Yin-Bo

    2013-07-01

    Arabidopsis trichomes are large branched single cells that protrude from the epidermis. The first morphological indication of trichome development is an increase in nuclear content resulting from an initial cycle of endoreduplication. Our previous study has shown that the C2H2 zinc finger protein GLABROUS INFLORESCENCE STEMS (GIS) is required for trichome initiation in the inflorescence organ and for trichome branching in response to gibberellic acid signaling, although GIS gene does not play a direct role in regulating trichome cell division. Here, we describe a novel role of GIS, controlling trichome cell division indirectly by interacting genetically with a key endoreduplication regulator SIAMESE (SIM). Our molecular and genetic studies have shown that GIS might indireclty control cell division and trichome branching by acting downstream of SIM. A loss of function mutation of SIM signficantly reduced the expression of GIS. Futhermore, the overexpression of GIS rescued the trichome cluster cell phenotypes of sim mutant. The gain or loss of function of GIS had no significant effect on the expression of SIM. These results suggest that GIS may play an indirect role in regulating trichome cell division by genetically interacting with SIM.

  4. Microstructural development inside the stress induced martensite variant in a Ti-Ni-Nb shape memory alloy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zheng, Y.F.; Cai, W.; Zhang, J.X.

    2000-04-03

    The microstructural development inside the stress induced martensite (SIM) variants in Ti-Ni-Nb alloy with various degrees of deformation have been revealed by electron microscopic observations. The orientation relationship between the SIM and the parent phase has been found: [1{bar 1}0]{sub M}{parallel}[11{bar 1}]{sub B2}, (001){sub M} 5{degree} away from (101){sub B2}. The lattice invariant shear of the SIM variants at the slightly deformed stage is dominantly (11{bar 1}) Type I twin. Besides the ordinary slip, the adjustment and development of the internal secondary twinning from (11{bar 1}) Type I twin to {l_angle}011{r_angle} Type II/ or (011) Type I twin, (001)compound twinmore » and (111) Type I twin happen concurrently or in combination inside the SIM variants with the further deformation. The corresponding deformation mechanisms include stress induced reorientation of SIM substructural bands by the most favorably oriented twin system, stress induced migration of the SIM substructural boundary through internal twinning and stress induced injection of foreign SIM variant to the preexisting substructural bands.« less

  5. The medical ethics of Dr J Marion Sims: a fresh look at the historical record.

    PubMed

    Wall, L L

    2006-06-01

    Vesicovaginal fistula was a catastrophic complication of childbirth among 19th century American women. The first consistently successful operation for this condition was developed by Dr J Marion Sims, an Alabama surgeon who carried out a series of experimental operations on black slave women between 1845 and 1849. Numerous modern authors have attacked Sims's medical ethics, arguing that he manipulated the institution of slavery to perform ethically unacceptable human experiments on powerless, unconsenting women. This article reviews these allegations using primary historical source material and concludes that the charges that have been made against Sims are largely without merit. Sims's modern critics have discounted the enormous suffering experienced by fistula victims, have ignored the controversies that surrounded the introduction of anaesthesia into surgical practice in the middle of the 19th century, and have consistently misrepresented the historical record in their attacks on Sims. Although enslaved African American women certainly represented a "vulnerable population" in the 19th century American South, the evidence suggests that Sims's original patients were willing participants in his surgical attempts to cure their affliction-a condition for which no other viable therapy existed at that time.

  6. SU-F-T-427: Utilization and Evaluation of Diagnostic CT Imaging with MAR Technique for Radiation Therapy Treatment Planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, M; Foster, R; Parks, H

    Purpose: The objective was to utilize and evaluate diagnostic CT-MAR technique for radiation therapy treatment planning. Methods: A Toshiba-diagnostic-CT acquisition with SEMAR(Single-energy-MAR)-algorism was performed to make the metal-artifact-reduction (MAR) for patient treatment planning. CT-imaging datasets with and without SEMAR were taken on a Catphan-phantom. Two sets of CT-numbers were calibrated with the relative electron densities (RED). A tissue characterization phantom with Gammex various simulating material rods was used to establish the relationship between known REDs and corresponding CT-numbers. A GE-CT-sim acquisition was taken on the Catphan for comparison. A patient with bilateral hip arthroplasty was scanned in the radiotherapy CT-simmore » and the diagnostic SEMAR-CT on a flat panel. The derived SEMAR images were used as a primary CT dataset to create contours for the target, critical-structures, and for planning. A deformable registration was performed with VelocityAI to track voxel changes between SEMAR and CT-sim images. The SEMAR-CT images with minimal artifacts and high quality of geometrical and spatial integrity were employed for a treatment plan. Treatment-plans were evaluated based on deformable registration of SEMAR-CT and CT-sim dataset with assigned CT-numbers in the metal artifact regions in Eclipse v11 TPS. Results: The RED and CT-number relationships were consistent for the datasets in CT-sim and CT’s with and without SEMAR. SEMAR datasets with high image quality were used for PTV and organ delineation in the treatment planning process. For dose distribution to the PTV through the DVH analysis, the plan using CT-sim with the assigned CT-number showed a good agreement to those on deformable CT-SEMAR. Conclusion: A diagnostic-CT with MAR-algorithm can be utilized for radiotherapy treatment planning with CT-number calibrated to the RED. Treatment planning comparison and DVH shows a good agreement in the PTV and critical organs between the plans on CT-sim with assigned CT-number and the deformable SEMAR CT datasets.« less

  7. Investigations into the metabolic diversity of microorganisms as part of microbial diversity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leadbetter, Jared

    DOE funds supported a key portion of the MBL Microbial Diversity (Woods Hole) program across 6 complete summers. The initial 4 years of the funded period were overseen by two co-Directors, Daniel Buckley (Cornell) and Steve Zinder (Cornell), who then completed their term. The final 2 summers were overseen by 2 new co-Directors, Jared R. Leadbetter (Caltech) and Dianne Newman (Caltech). The 6 funded summer iterations of the course included the incorporation of new themes such as single cell approaches applied to natural microbial communities (cell separation and sorting, genome amplification from single cells, and the use of Nano-SIMS tomore » examine assimilation of carbon and nitrogen from isotopically labeled substrates into single cells), genetics and genomics on bacteria freshly isolated during the course of the programs, quantitative systems biology, and modern quantitative light microscopy.« less

  8. Application of internal quality control to the analysis of quaternary ammonium compounds in surface and groundwater from Andalusia (Spain) by liquid chromatography with mass spectrometry.

    PubMed

    Vidal, J L Martínez; Vega, A Belmonte; López, F J Sánchez; Frenich, A Garrido

    2004-10-01

    A method has been developed for the simultaneous determination of paraquat (PQ), deiquat (DQ), chlormequat (CQ) and mepiquat (MQ) in water samples by liquid chromatography (LC) coupled with electrospray ionization mass spectrometry (MS). The LC separations of the target compounds, as well as their MS parameters, were optimized in order to improve selectivity and sensitivity. Separation was carried out in a Xterra C8 column, using as mobile phase methanol-heptafluorobutyric acid (HFBA) in isocratic mode. The molecular ion was selected for the quantitation in selected ion monitoring (SIM) mode. Off-line solid-phase extraction (SPE) was applied with silica cartridges in order to preconcentrate the compounds from waters. Detection limits were in the range 0.02-0.40 microg l(-1). Recovery range varied between 89 and 99.5% with precision values lower than 6%. The method has been applied successfully to the analysis of both surface and groundwater samples from agricultural areas of Andalusia (Spain), using well defined internal quality control (IQC) criteria. The results revealed the presence of deiquat and paraquat in some samples.

  9. A Computational Dual-Process Model of Social Interaction

    DTIC Science & Technology

    2014-01-30

    that portray the model’s behaviors when OMAR was adapted to operate first with Neverwinter Night and then with OpenSim . 3.1 Overview of Human...the Neverwinter Night (NwN; http://nwn.wikia.com) environment and more recently adapted to run with OpenSim (http://opensimulator.org). Figure 1...provides a screenshot of a scene from the NwN world while Figure 2 provides a screenshot from the OpenSim world. The NwN and OpenSim avatars and scenes

  10. Graph-based analysis of connectivity in spatially-explicit population models: HexSim and the Connectivity Analysis Toolkit

    EPA Science Inventory

    Background / Question / Methods Planning for the recovery of threatened species is increasingly informed by spatially-explicit population models. However, using simulation model results to guide land management decisions can be difficult due to the volume and complexity of model...

  11. Analysis of Sensitivity and Uncertainty in an Individual-Based Model of a Threatened Wildlife Species

    EPA Science Inventory

    We present a multi-faceted sensitivity analysis of a spatially explicit, individual-based model (IBM) (HexSim) of a threatened species, the Northern Spotted Owl (Strix occidentalis caurina) on a national forest in Washington, USA. Few sensitivity analyses have been conducted on ...

  12. Magnifying endoscopy for the diagnosis of specialized intestinal metaplasia in short-segment Barrett's esophagus.

    PubMed

    Ham, Nam Seok; Jang, Jae Young; Ryu, Sung Woo; Kim, Ji Hye; Park, Eui Ju; Lee, Woong Cheul; Shim, Kwang Yeun; Jeong, Soung Won; Kim, Hyun Gun; Lee, Tae Hee; Jeon, Sung Ran; Cho, Jun Hyung; Cho, Joo Young; Jin, So Young; Lee, Ji Sung

    2013-11-07

    To determine whether magnified observation of short-segment Barrett's esophagus (BE) is useful for the detection of specialized intestinal metaplasia (SIM). Thirty patients with suspected short-segment BE underwent magnifying endoscopy up to × 80. The magnified images were analyzed with respect to their pit-patterns, which were simultaneously classified into five epithelial types [I (small round), II (straight), III (long oval), IV (tubular), V (villous)] by Endo's classification. Then, a 0.5% solution of methylene blue (MB) was sprayed over columnar mucosa. The patterns of the magnified image and MB staining were analyzed. Biopsies were obtained from the regions previously observed by magnifying endoscopy and MB chromoendoscopy. Three of five patients with a type V (villous) epithelial pattern had SIM, whereas 21 patients with a non-type V epithelial patterns did not have SIM. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of pit-patterns in detecting SIM were 100%, 91.3%, 92.3%, 60% and 100%, respectively (P = 0.004). Three of the 12 patients with positive MB staining had SIM, whereas 14 patients with negative MB staining did not have SIM. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of MB staining in detecting SIM were 100%, 60.9%, 65.4%, 25% and 100%, respectively (P = 0.085). The specificity and accuracy of pit-pattern evaluation were significantly superior compared with MB staining for detecting SIM by comparison with the exact McNemar's test (P = 0.0391). The magnified observation of a short-segment BE according to the mucosal pattern and its classification can be predictive of SIM.

  13. Quantitative imaging of magnesium distribution at single-cell resolution in brain tumors and infiltrating tumor cells with secondary ion mass spectrometry (SIMS)

    PubMed Central

    Chandra, Subhash; Parker, Dylan J.; Barth, Rolf F.; Pannullo, Susan C.

    2016-01-01

    Glioblastoma multiforme (GBM) is one of the deadliest forms of human brain tumors. The infiltrative pattern of growth of these tumors includes the spread of individual and/or clusters of tumor cells at some distance from the main tumor mass in parts of the brain protected by an intact blood-brain-barrier. Pathophysiological studies of GBM could be greatly enhanced by analytical techniques capable of in situ single-cell resolution measurements of infiltrating tumor cells. Magnesium homeostasis is an area of active investigation in high grade gliomas. In the present study, we have used the F98 rat glioma as a model of human GBM and an elemental/isotopic imaging technique of secondary ion mass spectrometry (SIMS), a CAMECA IMS-3f ion microscope, for studying Mg distributions with single-cell resolution in freeze-dried brain tissue cryosections. Quantitative observations were made on tumor cells in the main tumor mass, contiguous brain tissue, and infiltrating tumor cells in adjacent normal brain. The brain tissue contained a significantly lower total Mg concentration of 4.70 ± 0.93 mmol/Kg wet weight (mean ± SD) in comparison to 11.64 ± 1.96 mmol/Kg wet weight in tumor cells of the main tumor mass and 10.72 ± 1.76 mmol/Kg wet weight in infiltrating tumor cells (p<0.05). The nucleus of individual tumor cells contained elevated levels of bound Mg. These observations demonstrate enhanced Mg-influx and increased binding of Mg in tumor cells and provide strong support for further investigation of GBMs for altered Mg homeostasis and activation of Mg-transporting channels as possible therapeutic targets. PMID:26703785

  14. Astrometric Planet Searches with SIM PlanetQuest

    NASA Technical Reports Server (NTRS)

    Beichman, Charles A.; Unwin, Stephen C.; Shao, Michael; Tanner, Angelle M.; Catanzarite, Joseph H.; March, Geoffrey W.

    2007-01-01

    SIM will search for planets with masses as small as the Earth's orbiting in the habitable zones' around more than 100 of the stars and could discover many dozen if Earth-like planets are common. With a planned 'Deep Survey' of 100-450 stars (depending on desired mass sensitivity) SIM will search for terrestrial planets around all of the candidate target stars for future direct detection missions such as Terrestrial Planet Finder and Darwin, SIM's 'Broad Survey' of 2010 stars will characterize single and multiple-planet systems around a wide variety of stellar types, including many now inaccessible with the radial velocity technique. In particular, SIM will search for planets around young stars providing insights into how planetary systems are born and evolve with time.

  15. Subcellular boron and fluorine distributions with SIMS ion microscopy in BNCT and cancer research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Subhash Chandra

    2008-05-30

    The development of a secondary ion mass spectrometry (SIMS) based technique of Ion Microscopy in boron neutron capture therapy (BNCT) was the main goal of this project, so that one can study the subcellular location of boron-10 atoms and their partitioning between the normal and cancerous tissue. This information is fundamental for the screening of boronated drugs appropriate for neutron capture therapy of cancer. Our studies at Cornell concentrated mainly on studies of glioblastoma multiforme (GBM). The early years of the grant were dedicated to the development of cryogenic methods and correlative microscopic approaches so that a reliable subcellular analysismore » of boron-10 atoms can be made with SIMS. In later years SIMS was applied to animal models and human tissues of GBM for studying the efficacy of potential boronated agents in BNCT. Under this grant the SIMS program at Cornell attained a new level of excellence and collaborative SIMS studies were published with leading BNCT researchers in the U.S.« less

  16. [Quality of data on deaths from external causes in a medium-sized city in Minas Gerais State, Brazil].

    PubMed

    Melo, Cristiane Magalhães de; Bevilacqua, Paula Dias; Barletto, Marisa; França, Elisabeth Barboza

    2014-09-01

    This study aimed to assess the quality of data on deaths from external causes in Viçosa, Minas Gerais State, Brazil, from 2000 to 2009, and the completeness of the Mortality Information System (SIM). The data were obtained from the SIM of the Municipal Health Department, municipal police enquiries, and local newspaper articles, resulting in a databank with 495 deaths from external causes. The results showed a high proportion of deaths with indeterminate intent (21%) in the SIM, suggesting problems with quality of information. Comparison of data from the SIM and police department detected problems with coverage in the SIM (21%) and thus in the official statistics on mortality from accidents and violence. The results emphasize the importance of searches in other data sources to upgrade the SIM and expand its coverage, and especially the need for studies to identify and analyze problems faced by small and medium-sized cities in the production of mortality data.

  17. Methodological development of topographic correction in 2D/3D ToF-SIMS images using AFM images

    NASA Astrophysics Data System (ADS)

    Jung, Seokwon; Lee, Nodo; Choi, Myungshin; Lee, Jungmin; Cho, Eunkyunng; Joo, Minho

    2018-02-01

    Time-of-flight secondary-ion mass spectrometry (ToF-SIMS) is an emerging technique that provides chemical information directly from the surface of electronic materials, e.g. OLED and solar cell. It is very versatile and highly sensitive mass spectrometric technique that provides surface molecular information with their lateral distribution as a two-dimensional (2D) molecular image. Extending the usefulness of ToF-SIMS, a 3D molecular image can be generated by acquiring multiple 2D images in a stack. These imaging techniques by ToF-SIMS provide an insight into understanding the complex structures of unknown composition in electronic material. However, one drawback in ToF-SIMS is not able to represent topographical information in 2D and 3D mapping images. To overcome this technical limitation, topographic information by ex-situ technique such as atomic force microscopy (AFM) has been combined with chemical information from SIMS that provides both chemical and physical information in one image. The key to combine two different images obtained from ToF-SIMS and AFM techniques is to develop the image processing algorithm, which performs resize and alignment by comparing the specific pixel information of each image. In this work, we present methodological development of the semiautomatic alignment and the 3D structure interpolation system for the combination of 2D/3D images obtained by ToF-SIMS and AFM measurements, which allows providing useful analytical information in a single representation.

  18. Educating resident physicians using virtual case-based simulation improves diabetes management: a randomized controlled trial.

    PubMed

    Sperl-Hillen, JoAnn; O'Connor, Patrick J; Ekstrom, Heidi L; Rush, William A; Asche, Stephen E; Fernandes, Omar D; Appana, Deepika; Amundson, Gerald H; Johnson, Paul E; Curran, Debra M

    2014-12-01

    To test a virtual case-based Simulated Diabetes Education intervention (SimDE) developed to teach primary care residents how to manage diabetes. Nineteen primary care residency programs, with 341 volunteer residents in all postgraduate years (PGY), were randomly assigned to a SimDE intervention group or control group (CG). The Web-based interactive educational intervention used computerized virtual patients who responded to provider actions through programmed simulation models. Eighteen distinct learning cases (L-cases) were assigned to SimDE residents over six months from 2010 to 2011. Impact was assessed using performance on four virtual assessment cases (A-cases), an objective knowledge test, and pre-post changes in self-assessed diabetes knowledge and confidence. Group comparisons were analyzed using generalized linear mixed models, controlling for clustering of residents within residency programs and differences in baseline knowledge. The percentages of residents appropriately achieving A-case composite clinical goals for glucose, blood pressure, and lipids were as follows: A-case 1: SimDE = 21.2%, CG = 1.8%, P = .002; A-case 2: SimDE = 15.7%, CG = 4.7%, P = .02; A-case 3: SimDE = 48.0%, CG = 10.4%, P < .001; and A-case 4: SimDE = 42.1%, CG = 18.7%, P = .004. The mean knowledge score and pre-post changes in self-assessed knowledge and confidence were significantly better for SimDE group than CG participants. A virtual case-based simulated diabetes education intervention improved diabetes management skills, knowledge, and confidence for primary care residents.

  19. Observation of endoplasmic reticulum tubules via TOF-SIMS tandem mass spectrometry imaging of transfected cells.

    PubMed

    Chini, Corryn E; Fisher, Gregory L; Johnson, Ben; Tamkun, Michael M; Kraft, Mary L

    2018-02-26

    Advances in three-dimensional secondary ion mass spectrometry (SIMS) imaging have enabled visualizing the subcellular distributions of various lipid species within individual cells. However, the difficulty of locating organelles using SIMS limits efforts to study their lipid compositions. Here, the authors have assessed whether endoplasmic reticulum (ER)-Tracker Blue White DPX ® , which is a commercially available stain for visualizing the endoplasmic reticulum using fluorescence microscopy, produces distinctive ions that can be used to locate the endoplasmic reticulum using SIMS. Time-of-flight-SIMS tandem mass spectrometry (MS 2 ) imaging was used to identify positively and negatively charged ions produced by the ER-Tracker stain. Then, these ions were used to localize the stain and thus the endoplasmic reticulum, within individual human embryonic kidney cells that contained higher numbers of endoplasmic reticulum-plasma membrane junctions on their surfaces. By performing MS 2 imaging of selected ions in parallel with the precursor ion (MS 1 ) imaging, the authors detected a chemical interference native to the cell at the same nominal mass as the pentafluorophenyl fragment from the ER-Tracker stain. Nonetheless, the fluorine secondary ions produced by the ER-Tracker stain provided a distinctive signal that enabled locating the endoplasmic reticulum using SIMS. This simple strategy for visualizing the endoplasmic reticulum in individual cells using SIMS could be combined with existing SIMS methodologies for imaging intracellular lipid distribution and to study the lipid composition within the endoplasmic reticulum.

  20. Vortex-homogenized matrix solid-phase dispersion for the extraction of short chain chlorinated paraffins from indoor dust samples.

    PubMed

    Chen, Yu-Hsuan; Chang, Chia-Yu; Ding, Wang-Hsien

    2016-11-11

    A simple and effective method for determining short chain chlorinated paraffins (SCCPs) in indoor dust is presented. The method employed a modified vortex-homogenized matrix solid-phase dispersion (VH-MSPD) prior to its detection by gas chromatography - electron-capture negative-ion mass spectrometry (GC-ECNI-MS) operating in the selected-ion-monitoring (SIM) mode. Under the best extraction conditions, 0.1-g of dust sample was dispersed with 0.1-g of silica gel by using vortex (2min) instead of using a mortar and pestle (3min). After that step, the blend was transferred to a glass column containing 3-g acidic silica gel, 2-g basic silica gel, and 2-g of deactivated silica gel, used as clean-up co-sorbents. Then, target analytes were eluted with 5mL of n-hexane/dichloromethane (2:1, v/v) mixture. The extract was evaporated to dryness under a gentle stream of nitrogen. The residue was then re-dissolved in n-hexane (10μL), and subjected to GC-ECNI-MS analysis. The limits of quantitation (LOQs) ranged from 0.06 to 0.25μg/g for each SCCP congener. Precision was less than 7% for both intra- and inter-day analysis. Trueness was above 89%, which was calculated by mean extraction recovery. The VH-MSPD combined with GC-ECNI-MS was successfully applied to quantitatively detect SCCPs from various indoor dust samples, and the concentrations ranged from 1.2 to 31.2μg/g. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. The HexSim Model

    EPA Science Inventory

    HexSim version 2.0 is soon to be released by EPA's Western Ecology Division (WED). More than three years of work have gone into the development of this tool, which grew out of an EPA model called PATCH. HexSim makes it possible for non-programmers to develop sophisticated simula...

  2. HexSim - A general purpose framework for spatially-explicit, individual-based modeling

    EPA Science Inventory

    HexSim is a framework for constructing spatially-explicit, individual-based computer models designed for simulating terrestrial wildlife population dynamics and interactions. HexSim is useful for a broad set of modeling applications. This talk will focus on a subset of those ap...

  3. [Intramuscular injection of lentivirus-mediated EPAS1 gene improves hind limb ischemia and its mechanism in a rat model of peripheral artery vascular disease].

    PubMed

    Wang, Zhihong; Gu, Hongbin; Yang, Fan; Xie, Huajie; Sheng, Lei; Li, Mingfei

    2017-11-01

    Objective To investigate the effect of over-expressed endothelial Per-Arnt-Sim domain protein 1 (EPAS1) on peripheral arterial disease (PAD) in a rat model. Methods PAD rat model was established by external iliac artery ligation followed by lentivirus-mediated EPAS1 gene injection into rat right adductor magnus. The models were evaluated by quantitative analysis of gait disturbance. The changes of blood flow in the posterior extremity of the rats were detected using laser Doppler. The expressions of EPAS1, hepatocyte growth factor (HGF), basic fibroblast growth factor (bFGF), and vascular endothelial growth factor (VEGF) mRNAs were tested by real-time quantitative PCR. The expression of α-smooth muscle actin (αSMA) was detected by immunohistochemical staining. Results Compared with lenti-EGFP group, rat hind limb function and circulation got recovered obviously 7 days after lenti-EPAS1 injection. The mRNA expressions of EPAS1, HGF, bFGF, and VEGF were up-regulated in the lenti-EPAS1-treated sites.The expression of αSMA showed an obvious increase in the lenti-EPAS1-treated muscles. Conclusion Over-expressed lenti-EPAS1 can promote angiogenesis via the up-regulation of EPAS1-related angiogenic factors in the muscles of the affected hind limb and reduce gait disturbance.

  4. Multi-spectroscopic analysis of cholesterol gallstone using TOF-SIMS, FTIR and UV-Vis spectroscopy

    NASA Astrophysics Data System (ADS)

    Jaswal, Brij Bir S.; Kumar, Vinay; Swart, H. C.; Sharma, Jitendra; Rai, Pradeep K.; Singh, Vivek K.

    2015-10-01

    For the first time, spatial distribution of major and trace elements has been studied in cholesterol gallstones using time-of-flight secondary mass ion mass spectrometry (TOF-SIMS). The TOF-SIMS has been used to study the elemental constituents of the center and surface parts of the gallstone sample. We have classified the gallstone sample using Fourier transform spectroscopy. The detected elements in cholesterol gallstone sample were carbon (C), hydrogen (H), calcium (Ca), sodium (Na), potassium (K), strontium (Sr), copper (Cu), iron (Fe), chromium (Cr), mercury (Hg) and lead (Pb). The detected molecules in the cholesterol gallstone were CH3 +, CO3 +, CaCO3 + and C3H+. Our results revealed that the contents of these elements in cholesterol gallstone were higher in the center part than that in the surface part. In the present paper, we have also presented the UV-Vis spectroscopic studies of the center and surface parts of the gallstone sample which indicated the presence of a higher content of cholesterol in the surface part and bilirubin in the center part.

  5. 3D ToF-SIMS Analysis of Peptide Incorporation into MALDI Matrix Crystals with Sub-micrometer Resolution.

    PubMed

    Körsgen, Martin; Pelster, Andreas; Dreisewerd, Klaus; Arlinghaus, Heinrich F

    2016-02-01

    The analytical sensitivity in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is largely affected by the specific analyte-matrix interaction, in particular by the possible incorporation of the analytes into crystalline MALDI matrices. Here we used time-of-flight secondary ion mass spectrometry (ToF-SIMS) to visualize the incorporation of three peptides with different hydrophobicities, bradykinin, Substance P, and vasopressin, into two classic MALDI matrices, 2,5-dihydroxybenzoic acid (DHB) and α-cyano-4-hydroxycinnamic acid (HCCA). For depth profiling, an Ar cluster ion beam was used to gradually sputter through the matrix crystals without causing significant degradation of matrix or biomolecules. A pulsed Bi3 ion cluster beam was used to image the lateral analyte distribution in the center of the sputter crater. Using this dual beam technique, the 3D distribution of the analytes and spatial segregation effects within the matrix crystals were imaged with sub-μm resolution. The technique could in the future enable matrix-enhanced (ME)-ToF-SIMS imaging of peptides in tissue slices at ultra-high resolution. Graphical Abstract ᅟ.

  6. 3D ToF-SIMS Analysis of Peptide Incorporation into MALDI Matrix Crystals with Sub-micrometer Resolution

    NASA Astrophysics Data System (ADS)

    Körsgen, Martin; Pelster, Andreas; Dreisewerd, Klaus; Arlinghaus, Heinrich F.

    2016-02-01

    The analytical sensitivity in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is largely affected by the specific analyte-matrix interaction, in particular by the possible incorporation of the analytes into crystalline MALDI matrices. Here we used time-of-flight secondary ion mass spectrometry (ToF-SIMS) to visualize the incorporation of three peptides with different hydrophobicities, bradykinin, Substance P, and vasopressin, into two classic MALDI matrices, 2,5-dihydroxybenzoic acid (DHB) and α-cyano-4-hydroxycinnamic acid (HCCA). For depth profiling, an Ar cluster ion beam was used to gradually sputter through the matrix crystals without causing significant degradation of matrix or biomolecules. A pulsed Bi3 ion cluster beam was used to image the lateral analyte distribution in the center of the sputter crater. Using this dual beam technique, the 3D distribution of the analytes and spatial segregation effects within the matrix crystals were imaged with sub-μm resolution. The technique could in the future enable matrix-enhanced (ME)-ToF-SIMS imaging of peptides in tissue slices at ultra-high resolution.

  7. SIMS of organics—Advances in 2D and 3D imaging and future outlook

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gilmore, Ian S.

    Secondary ion mass spectrometry (SIMS) has become a powerful technique for the label-free analysis of organics from cells to electronic devices. The development of cluster ion sources has revolutionized the field, increasing the sensitivity for organics by two or three orders of magnitude and for large clusters, such as C{sub 60} and argon clusters, allowing depth profiling of organics. The latter has provided the capability to generate stunning three dimensional images with depth resolutions of around 5 nm, simply unavailable by other techniques. Current state-of-the-art allows molecular images with a spatial resolution of around 500 nm to be achieved andmore » future developments are likely to progress into the sub-100 nm regime. This review is intended to bring those with some familiarity with SIMS up-to-date with the latest developments for organics, the fundamental principles that underpin this and define the future progress. State-of-the-art examples are showcased and signposts to more in-depth reviews about specific topics given for the specialist.« less

  8. Mechanical and Metallurgical Evolution of Stainless Steel 321 in a Multi-step Forming Process

    NASA Astrophysics Data System (ADS)

    Anderson, M.; Bridier, F.; Gholipour, J.; Jahazi, M.; Wanjara, P.; Bocher, P.; Savoie, J.

    2016-04-01

    This paper examines the metallurgical evolution of AISI Stainless Steel 321 (SS 321) during multi-step forming, a process that involves cycles of deformation with intermediate heat treatment steps. The multi-step forming process was simulated by implementing interrupted uniaxial tensile testing experiments. Evolution of the mechanical properties as well as the microstructural features, such as twins and textures of the austenite and martensite phases, was studied as a function of the multi-step forming process. The characteristics of the Strain-Induced Martensite (SIM) were also documented for each deformation step and intermediate stress relief heat treatment. The results indicated that the intermediate heat treatments considerably increased the formability of SS 321. Texture analysis showed that the effect of the intermediate heat treatment on the austenite was minor and led to partial recrystallization, while deformation was observed to reinforce the crystallographic texture of austenite. For the SIM, an Olson-Cohen equation type was identified to analytically predict its formation during the multi-step forming process. The generated SIM was textured and weakened with increasing deformation.

  9. Materials and Methods for Streamlined Laboratory Analysis of Environmental Samples, FY 2016 Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Addleman, Raymond S.; Naes, Benjamin E.; McNamara, Bruce K.

    The International Atomic Energy Agency (IAEA) relies upon laboratory analysis of environmental samples (typically referred to as “swipes”) collected during on-site inspections of safeguarded facilities to support the detection and deterrence of undeclared activities. Unfortunately, chemical processing and assay of the samples is slow and expensive. A rapid, effective, and simple extraction process and analysis method is needed to provide certified results with improved timeliness at reduced costs (principally in the form of reduced labor), while maintaining or improving sensitivity and efficacy. To address these safeguard needs the Pacific Northwest National Laboratory (PNNL) explored and demonstrated improved methods for environmentalmore » sample (ES) analysis. Improvements for both bulk and particle analysis were explored. To facilitate continuity and adoption, the new sampling materials and processing methods will be compatible with existing IAEA protocols for ES analysis. PNNL collaborated with Oak Ridge National Laboratory (ORNL), which performed independent validation of the new bulk analysis methods and compared performance to traditional IAEA’s Network of Analytical Laboratories (NWAL) protocol. ORNL efforts are reported separately. This report describes PNNL’s FY 2016 progress, which was focused on analytical application supporting environmental monitoring of uranium enrichment plants and nuclear fuel processing. In the future the technology could be applied to other safeguard applications and analytes related to fuel manufacturing, reprocessing, etc. PNNL’s FY 2016 efforts were broken into two tasks and a summary of progress, accomplishments and highlights are provided below. Principal progress and accomplishments on Task 1, Optimize Materials and Methods for ICP-MS Environmental Sample Analysis, are listed below. • Completed initial procedure for rapid uranium extraction from ES swipes based upon carbonate-peroxide chemistry (delivered to ORNL for evaluation). • Explored improvements to carbonate-peroxide rapid uranium extraction chemistry. • Evaluated new sampling materials and methods (in collaboration with ORNL). • Demonstrated successful ES extractions from standard and novel swipes for a wide range uranium compounds of interest including UO 2F 2 and UO 2(NO 3) 2, U 3O 8 and uranium ore concentrate. • Completed initial discussions with commercial suppliers of PTFE swipe materials. • Submitted one manuscript for publication. Two additional drafts are being prepared. Principal progress and accomplishments on Task 2, Optimize Materials and Methods for Direct SIMS Environmental Sample Analysis, are listed below. • Designed a SIMS swipe sample holder that retrofits into existing equipment and provides simple, effective, and rapid mounting of ES samples for direct assay while enabling automation and laboratory integration. • Identified preferred conductive sampling materials with better performance characteristics. • Ran samples on the new PNNL NWAL equivalent Cameca 1280 SIMS system. • Obtained excellent agreement between isotopic ratios for certified materials and direct SIMS assay of very low levels of LEU and HEU UO 2F 2 particles on carbon fiber sampling material. Sample activities range from 1 to 500 CPM (uranium mass on sample is dependent upon specific isotope ratio but is frequently in the subnanogram range). • Found that the presence of the UF molecular ions, as measured by SIMS, provides chemical information about the particle that is separate from the uranium isotopics and strongly suggests that those particles originated from an UF6 enrichment activity. • Submitted one manuscript for publication. Another manuscript is in preparation.« less

  10. Revisiting "Beyond Instructional Design"

    ERIC Educational Resources Information Center

    Sims, Rod

    2015-01-01

    Since the article "Beyond Instructional Design: Making Learning Design a Reality" (Sims, 2006) was published, much has changed in the opportunities we have for learning, and Professor Rod Sims's thinking has evolved. In this article, Professor Rod Sims reflects upon his original article, and he offers an evolved model of learning design,…

  11. Recent developments in the evolution of morphologies and controllers for physically simulated creatures.

    PubMed

    Taylor, T; Massey, C

    2001-01-01

    Karl Sims' work on evolving body shapes and controllers for three-dimensional, physically simulated creatures generated wide interest on its publication in 1994. The purpose of this article is threefold: (a) to highlight a spate of recent work by a number of researchers in replicating, and in some cases extending, Sims' results using standard PCs (Sims' original work was done on a Connection Machine CM-5 parallel computer). In particular, a re-implementation of Sims' work by the authors will be described and discussed; (b) to illustrate how off-the-shelf physics engines can be used in this sort of work, and also to highlight some deficiencies of these engines and pitfalls when using them; and (c) to indicate how these recent studies stand in respect to Sims' original work.

  12. Wind-farm simulation over moderately complex terrain

    NASA Astrophysics Data System (ADS)

    Segalini, Antonio; Castellani, Francesco

    2017-05-01

    A comparison between three independent software to estimate the power production and the flow field in a wind farm is conducted, validating them against SCADA (Supervisory, Control And Data Acquisition) data. The three software were ORFEUS, WindSim and WAsP: ORFEUS and WAsP are linearised solvers, while WindSim is fully nonlinear. A wake model (namely a prescribed velocity deficit associated to the turbines) is used by WAsP, while ORFEUS and WindSim use the actuator-disc method to account for the turbines presence. The comparison indicates that ORFEUS and WAsP perform slightly better than WindSim in the assessment of the polar efficiency. The wakes simulated with ORFEUS appear more persistent than the ones of WindSim, which uses a two-equation closure model for the turbulence effects.

  13. GneimoSim: A Modular Internal Coordinates Molecular Dynamics Simulation Package

    PubMed Central

    Larsen, Adrien B.; Wagner, Jeffrey R.; Kandel, Saugat; Salomon-Ferrer, Romelia; Vaidehi, Nagarajan; Jain, Abhinandan

    2014-01-01

    The Generalized Newton Euler Inverse Mass Operator (GNEIMO) method is an advanced method for internal coordinates molecular dynamics (ICMD). GNEIMO includes several theoretical and algorithmic advancements that address longstanding challenges with ICMD simulations. In this paper we describe the GneimoSim ICMD software package that implements the GNEIMO method. We believe that GneimoSim is the first software package to include advanced features such as the equipartition principle derived for internal coordinates, and a method for including the Fixman potential to eliminate systematic statistical biases introduced by the use of hard constraints. Moreover, by design, GneimoSim is extensible and can be easily interfaced with third party force field packages for ICMD simulations. Currently, GneimoSim includes interfaces to LAMMPS, OpenMM, Rosetta force field calculation packages. The availability of a comprehensive Python interface to the underlying C++ classes and their methods provides a powerful and versatile mechanism for users to develop simulation scripts to configure the simulation and control the simulation flow. GneimoSim has been used extensively for studying the dynamics of protein structures, refinement of protein homology models, and for simulating large scale protein conformational changes with enhanced sampling methods. GneimoSim is not limited to proteins and can also be used for the simulation of polymeric materials. PMID:25263538

  14. Phytoremediation of the organic Xenobiotic simazine by p450-1a2 transgenic Arabidopsis thaliana plants.

    PubMed

    Azab, Ehab; Hegazy, Ahmad K; El-Sharnouby, Mohamed E; Abd Elsalam, Hassan E

    2016-01-01

    The potential use of human P450-transgenic plants for phytoremediation of pesticide contaminated soils was tested in laboratory and greenhouse experiments. The transgenic P450 CYP1A2 gene Arabidopsis thaliana plants metabolize number of herbicides, insecticides and industrial chemicals. The P450 isozymes CYP1A2 expressed in A. thaliana were examined regarding the herbicide simazine (SIM). Transgenic A. thaliana plants expressing CYP1A2 gene showed significant resistance to SIM supplemented either in plant growth medium or sprayed on foliar parts. The results showed that SIM produces harmful effect on both rosette diameter and primary root length of the wild type (WT) plants. In transgenic A. thaliana lines, the rosette diameter and primary root length were not affected by SIM concentrations used in this experiment. The results indicate that CYP1A2 can be used as a selectable marker for plant transformation, allowing efficient selection of transgenic lines in growth medium and/or in soil-grown plants. The transgenic A. thaliana plants exhibited a healthy growth using doses of up to 250 μmol SIM treatments, while the non-transgenic A. thaliana plants were severely damaged with doses above 50 μmol SIM treatments. The transgenic A. thaliana plants can be used as phytoremediator of environmental SIM contaminants.

  15. GneimoSim: a modular internal coordinates molecular dynamics simulation package.

    PubMed

    Larsen, Adrien B; Wagner, Jeffrey R; Kandel, Saugat; Salomon-Ferrer, Romelia; Vaidehi, Nagarajan; Jain, Abhinandan

    2014-12-05

    The generalized Newton-Euler inverse mass operator (GNEIMO) method is an advanced method for internal coordinates molecular dynamics (ICMD). GNEIMO includes several theoretical and algorithmic advancements that address longstanding challenges with ICMD simulations. In this article, we describe the GneimoSim ICMD software package that implements the GNEIMO method. We believe that GneimoSim is the first software package to include advanced features such as the equipartition principle derived for internal coordinates, and a method for including the Fixman potential to eliminate systematic statistical biases introduced by the use of hard constraints. Moreover, by design, GneimoSim is extensible and can be easily interfaced with third party force field packages for ICMD simulations. Currently, GneimoSim includes interfaces to LAMMPS, OpenMM, and Rosetta force field calculation packages. The availability of a comprehensive Python interface to the underlying C++ classes and their methods provides a powerful and versatile mechanism for users to develop simulation scripts to configure the simulation and control the simulation flow. GneimoSim has been used extensively for studying the dynamics of protein structures, refinement of protein homology models, and for simulating large scale protein conformational changes with enhanced sampling methods. GneimoSim is not limited to proteins and can also be used for the simulation of polymeric materials. © 2014 Wiley Periodicals, Inc.

  16. Enhancing the isotropy of lateral resolution in coherent structured illumination microscopy

    PubMed Central

    Park, Joo Hyun; Lee, Jae Yong; Lee, Eun Seong

    2014-01-01

    We present a method to improve the isotropy of spatial resolution in a structured illumination microscopy (SIM) implemented for imaging non-fluorescent samples. To alleviate the problem of anisotropic resolution involved with the previous scheme of coherent SIM that employs the two orthogonal standing-wave illumination, referred to as the orthogonal SIM, we introduce a hexagonal-lattice illumination that incorporates three standing-wave fields simultaneously superimposed at the orientations equally divided in the lateral plane. A theoretical formulation is worked out rigorously for the coherent image formation with such a simultaneous multiple-beam illumination and an explicit Fourier-domain framework is derived for reconstructing an image with enhanced resolution. Using a computer-synthesized resolution target as a 2D coherent sample, we perform numerical simulations to examine the imaging characteristics of our three-angle SIM compared with the orthogonal SIM. The investigation on the 2D resolving power with the various test patterns of different periods and orientations reveal that the orientation-dependent undulation of lateral resolution can be reduced from 27% to 8% by using the three-angle SIM while the best resolution (0.54 times the resolution limit of conventional coherent imaging) in the directions of structured illumination is slightly deteriorated by 4.6% from that of the orthogonal SIM. PMID:24940548

  17. DOE/NASA SIMS Prototype Solar System, no. 4. Part 1: Market analysis. Part 2: Modular manufacturing cost estimate

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The findings of the IIT Research Institute (IITRI) market study of the SIMS Prototype System 4, a hot water (DHW) system are documented. The feasibility of prepackaging currently available solar heating components into modular subsystems for site assembly is addressed. A documented design and installation procedure and a performance test report were prepared. The potential markets and applications for this particular system in the nonfederal market are profiled by assessing the needs and requirements of potential users and specifiers, by characterizing the nature of the market and the competitive environment, by identifying the barriers to commercial acceptance, and by estimating the size of the potential market.

  18. Protein adsorption/desorption and antibody binding stoichiometry on silicon interferometric biosensors examined with TOF-SIMS

    NASA Astrophysics Data System (ADS)

    Gajos, Katarzyna; Budkowski, Andrzej; Petrou, Panagiota; Pagkali, Varvara; Awsiuk, Kamil; Rysz, Jakub; Bernasik, Andrzej; Misiakos, Konstantinos; Raptis, Ioannis; Kakabakos, Sotirios

    2018-06-01

    Time-of-flight secondary ion mass spectrometry has been employed to examine, with biomolecular discrimination, sensing arm areas (20 μm × 600 μm) of integrated onto silicon chips Mach-Zehnder interferometers aiming to optimize their biofunctionalization with regard to indirect immunochemical (competitive) detection of ochratoxin A. Sensing areas are examined after: modification with (3-aminopropyl)triethoxysilane, spotting of OTA-ovalbumin conjugate (probe) from solutions with different concentration, blocking with bovine serum albumin, reaction with OTA-specific mouse monoclonal antibody followed by goat anti-mouse IgG secondary antibody. Component mass loadings of all proteins involved in immunodetection are determined from TOF-SIMS micro-analysis combined with ellipsometry of planar surfaces. These data show that partial desorption of surface-bound probe and blocking protein takes place upon primary immunoreaction to a degree that depends on probe concentration in spotting solution. Taking into account this desorption, apparent binding stoichiometry of both antibodies in immune complexes formed onto chip surface is determined more accurately than the respective evaluation based on real-time sensor response. In addition, mass loadings for probe and secondary antibody is observed to saturate for optimum probe concentrations. Also, principal component analysis of TOF-SIMS data could resolve both immunoreactions and biofunctionalization and discriminate surfaces prepared with optimum probe concentrations from those prepared using suboptimum ones.

  19. High mass and spatial resolution mass spectrometry imaging of Nicolas Poussin painting cross section by cluster TOF-SIMS.

    PubMed

    Noun, M; Van Elslande, E; Touboul, D; Glanville, H; Bucklow, S; Walter, P; Brunelle, A

    2016-12-01

    The painting Rebecca and Eliezer at the Well, which hangs in the Fitzwilliam Museum, Cambridge, UK, is possibly one of the last figure painting executed by Nicolas Poussin at the very end of his life and is usually dated to the early 1660s. In this perspective special feature, Philippe Walter, Alain Brunelle and colleagues give new insights on the artist's working methods by a careful stateof-the-art imaging ToF-SIMS study of one sample taken on the edge of the painting. This approach allowed for the identification of the pigments used in the painting, their nature and components and those of the ground and preparatory layers, with the identification of the binder(s) and possible other additions of organic materials such as glue. This study paves the way to a wider use of ToF-SIMS for the analysis of ancient cultural heritage artefacts. Dr. Walter is the Director of the Molecular and Structural Archeology Laboratory (Université Pierre et Marie Curie, Paris, France). Dr. Brunelle is Head of the Mass Spectrometry Laboratory at the Institut de Chimie des Substances Naturelles (CNRS, Gif-sur-Yvette, France). Their long standing collaboration has led to several seminal publications on the analysis of ancient artefacts by mass spectrometry. Copyright © 2016 John Wiley & Sons, Ltd.

  20. Characterization of extreme ultraviolet laser ablation mass spectrometry for actinide trace analysis and nanoscale isotopic imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Green, Tyler; Kuznetsov, Ilya; Willingham, David

    The purpose of this research was to characterize Extreme Ultraviolet Time-of-Flight (EUV TOF) Laser Ablation Mass Spectrometry for high spatial resolution elemental and isotopic analysis. We compare EUV TOF results with Secondary Ionization Mass Spectrometry (SIMS) to orient the EUV TOF method within the overall field of analytical mass spectrometry. Using the well-characterized NIST 61x glasses, we show that the EUV ionization approach produces relatively few molecular ion interferences in comparison to TOF SIMS. We demonstrate that the ratio of element ion to element oxide ion is adjustable with EUV laser pulse energy and that the EUV TOF instrument hasmore » a sample utilization efficiency of 0.014%. The EUV TOF system also achieves a lateral resolution of 80 nm and we demonstrate this lateral resolution with isotopic imaging of closely spaced particles or uranium isotopic standard materials.« less

Top