Sample records for quantitative survey instrument

  1. SURVEY INSTRUMENT

    DOEpatents

    Borkowski, C J

    1954-01-19

    This pulse-type survey instrument is suitable for readily detecting {alpha} particles in the presence of high {beta} and {gamma} backgrounds. The instruments may also be used to survey for neutrons, {beta} particles and {gamma} rays by employing suitably designed interchangeable probes and selecting an operating potential to correspond to the particular probe.

  2. The development of a survey instrument for community health improvement.

    PubMed Central

    Bazos, D A; Weeks, W B; Fisher, E S; DeBlois, H A; Hamilton, E; Young, M J

    2001-01-01

    adequate. Face validity was supported by previous findings from qualitative and quantitative studies. CONCLUSIONS: We developed, pilot tested, and validated a survey instrument designed to provide more comprehensive and timely data to communities for community health assessments. This instrument allows communities to identify and measure critical domains of health that have previously not been captured in a single instrument. PMID:11508639

  3. Prototype ultrasonic instrument for quantitative testing

    NASA Technical Reports Server (NTRS)

    Lynnworth, L. C.; Dubois, J. L.; Kranz, P. R.

    1972-01-01

    A prototype ultrasonic instrument has been designed and developed for quantitative testing. The complete delivered instrument consists of a pulser/receiver which plugs into a standard oscilloscope, an rf power amplifier, a standard decade oscillator, and a set of broadband transducers for typical use at 1, 2, 5 and 10 MHz. The system provides for its own calibration, and on the oscilloscope, presents a quantitative (digital) indication of time base and sensitivity scale factors and some measurement data.

  4. 10 CFR 34.25 - Radiation survey instruments.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Radiation survey instruments. 34.25 Section 34.25 Energy... INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.25 Radiation survey instruments. (a) The licensee shall keep sufficient calibrated and operable radiation survey instruments at each location where radioactive...

  5. 10 CFR 34.25 - Radiation survey instruments.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Radiation survey instruments. 34.25 Section 34.25 Energy... INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.25 Radiation survey instruments. (a) The licensee shall keep sufficient calibrated and operable radiation survey instruments at each location where radioactive...

  6. 10 CFR 34.25 - Radiation survey instruments.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Radiation survey instruments. 34.25 Section 34.25 Energy... INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.25 Radiation survey instruments. (a) The licensee shall keep sufficient calibrated and operable radiation survey instruments at each location where radioactive...

  7. 10 CFR 34.25 - Radiation survey instruments.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Radiation survey instruments. 34.25 Section 34.25 Energy... INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.25 Radiation survey instruments. (a) The licensee shall keep sufficient calibrated and operable radiation survey instruments at each location where radioactive...

  8. 10 CFR 35.61 - Calibration of survey instruments.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Calibration of survey instruments. 35.61 Section 35.61... § 35.61 Calibration of survey instruments. (a) A licensee shall calibrate the survey instruments used... of calibration. (b) A licensee may not use survey instruments if the difference between the indicated...

  9. 10 CFR 35.61 - Calibration of survey instruments.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Calibration of survey instruments. 35.61 Section 35.61... § 35.61 Calibration of survey instruments. (a) A licensee shall calibrate the survey instruments used... of calibration. (b) A licensee may not use survey instruments if the difference between the indicated...

  10. 10 CFR 35.61 - Calibration of survey instruments.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Calibration of survey instruments. 35.61 Section 35.61... § 35.61 Calibration of survey instruments. (a) A licensee shall calibrate the survey instruments used... of calibration. (b) A licensee may not use survey instruments if the difference between the indicated...

  11. 10 CFR 35.61 - Calibration of survey instruments.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Calibration of survey instruments. 35.61 Section 35.61... § 35.61 Calibration of survey instruments. (a) A licensee shall calibrate the survey instruments used... of calibration. (b) A licensee may not use survey instruments if the difference between the indicated...

  12. [Instruments for quantitative methods of nursing research].

    PubMed

    Vellone, E

    2000-01-01

    Instruments for quantitative nursing research are a mean to objectify and measure a variable or a phenomenon in the scientific research. There are direct instruments to measure concrete variables and indirect instruments to measure abstract concepts (Burns, Grove, 1997). Indirect instruments measure the attributes by which a concept is made of. Furthermore, there are instruments for physiologic variables (e.g. for the weight), observational instruments (Check-lists e Rating Scales), interviews, questionnaires, diaries and the scales (Check-lists, Rating Scales, Likert Scales, Semantic Differential Scales e Visual Anologue Scales). The choice to select an instrument or another one depends on the research question and design. Instruments research are very useful in research both to describe the variables and to see statistical significant relationships. Very carefully should be their use in the clinical practice for diagnostic assessment.

  13. 10 CFR 34.25 - Radiation survey instruments.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Radiation survey instruments. 34.25 Section 34.25 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.25 Radiation survey instruments. (a) The licensee shall...

  14. Borehole survey instrument

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sharp, H.E.; Lin, J.W. III; Macha, E.S.

    1984-12-04

    A borehole survey instrument is provided having a meniscus type floating compass member with indicia thereon for indicating azimuth and inclination. A light source is disposed below the indicia for illuminating the indicia upward through the liquid through which the meniscus type floating compass member floats. A lens system is provided for focusing the image of the illuminated compass member upon a film disposed below the compass member. This arrangement permits the centering post for the compass member to be of minimum diameter consistent with rigidity requirements and permits a high angle compass member to indicate angles of inclination approachingmore » ninety degrees. A multiple light bulb light source is utilized and each light bulb is mounted in a manner which permits a single light bulb to illuminate the entire compass member. A hand-held programming and diagnostic unit is provided which may be momentarily electrically mated with the borehole survey tool to input a programmed timed delay and diagnostically test both the condition of the light bulbs utilized as the illumination source and the state of the batteries within the instrument. This hand-held programmable unit eliminates all the mechanical programming switches and permits the instrument to be completely sealed from the pressure, fluids and contaminants normally found in a well bore.« less

  15. 10 CFR 35.2061 - Records of radiation survey instrument calibrations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Records of radiation survey instrument calibrations. 35... § 35.2061 Records of radiation survey instrument calibrations. A licensee shall maintain a record of radiation survey instrument calibrations required by § 35.61 for 3 years. The record must include the model...

  16. 10 CFR 35.2061 - Records of radiation survey instrument calibrations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Records of radiation survey instrument calibrations. 35... § 35.2061 Records of radiation survey instrument calibrations. A licensee shall maintain a record of radiation survey instrument calibrations required by § 35.61 for 3 years. The record must include the model...

  17. 10 CFR 35.2061 - Records of radiation survey instrument calibrations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Records of radiation survey instrument calibrations. 35... § 35.2061 Records of radiation survey instrument calibrations. A licensee shall maintain a record of radiation survey instrument calibrations required by § 35.61 for 3 years. The record must include the model...

  18. 10 CFR 35.2061 - Records of radiation survey instrument calibrations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Records of radiation survey instrument calibrations. 35... § 35.2061 Records of radiation survey instrument calibrations. A licensee shall maintain a record of radiation survey instrument calibrations required by § 35.61 for 3 years. The record must include the model...

  19. 10 CFR 35.2061 - Records of radiation survey instrument calibrations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Records of radiation survey instrument calibrations. 35... § 35.2061 Records of radiation survey instrument calibrations. A licensee shall maintain a record of radiation survey instrument calibrations required by § 35.61 for 3 years. The record must include the model...

  20. Calendar Instruments in Retrospective Web Surveys

    ERIC Educational Resources Information Center

    Glasner, Tina; van der Vaart, Wander; Dijkstra, Wil

    2015-01-01

    Calendar instruments incorporate aided recall techniques such as temporal landmarks and visual time lines that aim to reduce response error in retrospective surveys. Those calendar instruments have been used extensively in off-line research (e.g., computer-aided telephone interviews, computer assisted personal interviewing, and paper and pen…

  1. Quantitative instruments used to assess children's sense of smell: a review article.

    PubMed

    Moura, Raissa Gomes Fonseca; Cunha, Daniele Andrade; Gomes, Ana Carolina de Lima Gusmão; Silva, Hilton Justino da

    2014-01-01

    To systematically gather from the literature available the quantitative instruments used to assess the sense of smell in studies carried out with children. The present study included a survey in the Pubmed and Bireme platforms and in the databases of MedLine, Lilacs, regional SciELO and Web of Science, followed by selection and critical analysis of the articles found and chosen. We selected original articles related to the topic in question, conducted only with children in Portuguese, English, and Spanish. We excluded studies addressing other phases of human development, exclusively or concurrently with the pediatric population; studies on animals; literature review articles; dissertations; book chapters; case study articles; and editorials. A book report protocol was created for this study, including the following information: author, department, year, location, population/sample, age, purpose of the study, methods, and main results. We found 8,451 articles by typing keywords and identifiers. Out of this total, 5,928 were excluded by the title, 2,366 by the abstract, and 123 after we read the full text. Thus, 34 articles were selected, of which 28 were repeated in the databases, totalizing 6 articles analyzed in this review. We observed a lack of standardization of the quantitative instruments used to assess children's sense of smell, with great variability in the methodology of the tests, which reduces the effectiveness and reliability of the results.

  2. Survey Instrument Validity Part I: Principles of Survey Instrument Development and Validation in Athletic Training Education Research

    ERIC Educational Resources Information Center

    Burton, Laura J.; Mazerolle, Stephanie M.

    2011-01-01

    Context: Instrument validation is an important facet of survey research methods and athletic trainers must be aware of the important underlying principles. Objective: To discuss the process of survey development and validation, specifically the process of construct validation. Background: Athletic training researchers frequently employ the use of…

  3. New Faculty Survey Instrument.

    ERIC Educational Resources Information Center

    National Center on Postsecondary Teaching, Learning, and Assessment, University Park, PA.

    This publication is a survey to be used by institutions of higher education in the United States in creating a profile of new faculty. An introduction notes that this instrument was administered at 5 schools (2 liberal arts colleges, a community college, a comprehensive university, and a research university) and that 53 percent of the respondents…

  4. Nuclear medicine and quantitative imaging research (instrumentation and quantitative methods of evaluation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beck, R.N.; Cooper, M.D.

    1990-09-01

    This report summarizes goals and accomplishments of the research program supported under DOE Grant No. FG02-86ER60418 entitled Instrumentation and Quantitative Methods of Evaluation, with R. Beck, P. I. and M. Cooper, Co-P.I. during the period January 15, 1990 through September 1, 1990. This program addresses the problems involving the basic science and technology underlying the physical and conceptual tools of radioactive tracer methodology as they relate to the measurement of structural and functional parameters of physiologic importance in health and disease. The principal tool is quantitative radionuclide imaging. The overall objective of this program is to further the development andmore » transfer of radiotracer methodology from basic theory to routine clinical practice in order that individual patients and society as a whole will receive the maximum net benefit from the new knowledge gained. The focus of the research is on the development of new instruments and radiopharmaceuticals, and the evaluation of these through the phase of clinical feasibility. 7 figs.« less

  5. Development of a Conceptual Model and Survey Instrument to Measure Conscientious Objection to Abortion Provision.

    PubMed

    Harris, Laura Florence; Awoonor-Williams, John Koku; Gerdts, Caitlin; Gil Urbano, Laura; González Vélez, Ana Cristina; Halpern, Jodi; Prata, Ndola; Baffoe, Peter

    2016-01-01

    Conscientious objection to abortion, clinicians' refusal to perform legal abortions because of their religious or moral beliefs, has been the subject of increasing debate among bioethicists, policymakers, and public health advocates in recent years. Conscientious objection policies are intended to balance reproductive rights and clinicians' beliefs. However, in practice, clinician objection can act as a barrier to abortion access-impinging on reproductive rights, and increasing unsafe abortion and related morbidity and mortality. There is little information about conscientious objection from a medical or public health perspective. A quantitative instrument is needed to assess prevalence of conscientious objection and to provide insight on its practice. This paper describes the development of a survey instrument to measure conscientious objection to abortion provision. A literature review, and in-depth formative interviews with stakeholders in Colombia were used to develop a conceptual model of conscientious objection. This model led to the development of a survey, which was piloted, and then administered, in Ghana. The model posits three domains of conscientious objection that form the basis for the survey instrument: 1) beliefs about abortion and conscientious objection; 2) actions related to conscientious objection and abortion; and 3) self-identification as a conscientious objector. The instrument is intended to be used to assess prevalence among clinicians trained to provide abortions, and to gain insight on how conscientious objection is practiced in a variety of settings. Its results can inform more effective and appropriate strategies to regulate conscientious objection.

  6. Measuring teamwork in health care settings: a review of survey instruments.

    PubMed

    Valentine, Melissa A; Nembhard, Ingrid M; Edmondson, Amy C

    2015-04-01

    Teamwork in health care settings is widely recognized as an important factor in providing high-quality patient care. However, the behaviors that comprise effective teamwork, the organizational factors that support teamwork, and the relationship between teamwork and patient outcomes remain empirical questions in need of rigorous study. To identify and review survey instruments used to assess dimensions of teamwork so as to facilitate high-quality research on this topic. We conducted a systematic review of articles published before September 2012 to identify survey instruments used to measure teamwork and to assess their conceptual content, psychometric validity, and relationships to outcomes of interest. We searched the ISI Web of Knowledge database, and identified relevant articles using the search terms team, teamwork, or collaboration in combination with survey, scale, measure, or questionnaire. We found 39 surveys that measured teamwork. Surveys assessed different dimensions of teamwork. The most commonly assessed dimensions were communication, coordination, and respect. Of the 39 surveys, 10 met all of the criteria for psychometric validity, and 14 showed significant relationships to nonself-report outcomes. Evidence of psychometric validity is lacking for many teamwork survey instruments. However, several psychometrically valid instruments are available. Researchers aiming to advance research on teamwork in health care should consider using or adapting one of these instruments before creating a new one. Because instruments vary considerably in the behavioral processes and emergent states of teamwork that they capture, researchers must carefully evaluate the conceptual consistency between instrument, research question, and context.

  7. Corporate Entrepreneurship Assessment Instrument (CEAI): Refinement and Validation of a Survey Measure

    DTIC Science & Technology

    2007-03-01

    CORPORATE ENTREPRENEURSHIP ASSESSMENT INSTRUMENT (CEAI): REFINEMENT AND VALIDATION OF A SURVEY MEASURE...States Government. AFIT/GIR/ENV/07-M7 CORPORATE ENTREPRENEURSHIP ASSESSMENT INSTRUMENT (CEAI): REFINEMENT AND VALIDATION OF A SURVEY MEASURE...UNLIMITED AFIT/GIR/ENV/07-M7 CORPORATE ENTREPRENEURSHIP ASSESSMENT INSTRUMENT (CEAI): REFINEMENT AND VALIDATION OF A SURVEY MEASURE Michael

  8. Academic Research Equipment in the Physical and Computer Sciences and Engineering. An Analysis of Findings from Phase I of the National Science Foundation's National Survey of Academic Research Instruments and Instrumentation Needs.

    ERIC Educational Resources Information Center

    Burgdorf, Kenneth; White, Kristine

    This report presents information from phase I of a survey designed to develop quantitative indicators of the current national stock, cost/investment, condition, obsolescence, utilization, and need for major research instruments in academic settings. Data for phase I (which focused on the physical and computer sciences and engineering) were…

  9. Instrument and Survey Analysis Technical Report: Program Implementation Survey. Technical Report #1112

    ERIC Educational Resources Information Center

    Alonzo, Julie; Tindal, Gerald

    2011-01-01

    This technical document provides guidance to educators on the creation and interpretation of survey instruments, particularly as they relate to an analysis of program implementation. Illustrative examples are drawn from a survey of educators related to the use of the easyCBM learning system. This document includes specific sections on…

  10. Survey of quantitative data on the solar energy and its spectra distribution

    NASA Technical Reports Server (NTRS)

    Thekaekara, M. P.

    1976-01-01

    This paper presents a survey of available quantitative data on the total and spectral solar irradiance at ground level and outside the atmosphere. Measurements from research aircraft have resulted in the currently accepted NASA/ASTM standards of the solar constant and zero air mass solar spectral irradiance. The intrinsic variability of solar energy output and programs currently under way for more precise measurements from spacecraft are discussed. Instrumentation for solar measurements and their reference radiation scales are examined. Insolation data available from the records of weather stations are reviewed for their applicability to solar energy conversion. Two alternate methods of solarimetry are briefly discussed.

  11. Survey Instrument Validity Part II: Validation of a Survey Instrument Examining Athletic Trainers' Knowledge and Practice Beliefs Regarding Exertional Heat Stroke

    ERIC Educational Resources Information Center

    Burton, Laura J.; Mazerolle, Stephanie M.

    2011-01-01

    Objective: The purpose of this article is to discuss the process of developing and validating an instrument to investigate an athletic trainer's attitudes and behaviors regarding the recognition and treatment of exertional heat stroke. Background: Following up from our initial paper, which discussed the process of survey instrument design and…

  12. The Hydrologic Instrumentation Facility of the U.S. Geological Survey

    USGS Publications Warehouse

    Wagner, C.R.; Jeffers, Sharon

    1984-01-01

    The U.S. Geological Survey Water Resources Division has improved support to the agencies field offices by the consolidation of all instrumentation support services in a single facility. This facility known as the Hydrologic Instrumentation Facility (HIF) is located at the National Space Technology Laboratory, Mississippi, about 50 miles east of New Orleans, Louisiana. The HIF is responsible for design and development, testing, evaluation, procurement, warehousing, distribution and repair of a variety of specialized hydrologic instrumentation. The centralization has resulted in more efficient and effective support of the Survey 's hydrologic programs. (USGS)

  13. Survey of instrumentation for environmental monitoring: major update. Volume 3. Radiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1979-09-01

    This is the third volume of a four-volume (seven-part) series, the culmination of a comprehensive survey of instrumentation for environmental monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to radiation monitoring. The results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored, their characteristics and forms, their sources and pathways, their effects on themore » ecosystem, and the means of controlling them through process and regulatory controls. The discussion is presented under sections entitled radiation sources; instrumentation: by type of radiation or instrument type; and, instrumentation for specific radionuclides. (JGB)« less

  14. Survey of beam instrumentation used in SLC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ecklund, S.D.

    A survey of beam instruments used at SLAC in the SLC machine is presented. The basic utility and operation of each device is briefly described. The various beam instruments used at the Stanford Linear Collider (SLC), can be classified by the function they perform. Beam intensity, position and size are typical of the parameters of beam which are measured. Each type of parameter is important for adjusting or tuning the machine in order to achieve optimum performance. 39 refs.

  15. The Gaia spectrophotometric standard stars survey: II. Instrumental effects of six ground-based observing campaigns

    NASA Astrophysics Data System (ADS)

    Altavilla, G.; Marinoni, S.; Pancino, E.; Galleti, S.; Ragaini, S.; Bellazzini, M.; Cocozza, G.; Bragaglia, A.; Carrasco, J. M.; Castro, A.; Di Fabrizio, L.; Federici, L.; Figueras, F.; Gebran, M.; Jordi, C.; Masana, E.; Schuster, W.; Valentini, G.; Voss, H.

    2015-08-01

    The Gaia SpectroPhotometric Standard Stars (SPSS) survey started in 2006, was awarded almost 450 observing nights and accumulated almost 100 000 raw data frames with both photometric and spectroscopic observations. Such large observational effort requires careful, homogeneous, and automatic data reduction and quality control procedures. In this paper, we quantitatively evaluate instrumental effects that might have a significant (i.e., ≥ 1 %) impact on the Gaia SPSS flux calibration. The measurements involve six different instruments, monitored over the eight years of observations dedicated to the Gaia flux standards campaigns: DOLORES@TNG in La Palma, EFOSC2@NTT and ROSS@REM in La Silla, CAFOS@2.2 m in Calar Alto, BFOSC@Cassini in Loiano, and LaRuca@1.5 m in San Pedro Mártir. We examine and quantitatively evaluate the following effects: CCD linearity and shutter times, calibration frames stability, lamp flexures, second order contamination, light polarization, and fringing. We present methods to correct for the relevant effects which can be applied to a wide range of observational projects at similar instruments. Based on data obtained with BFOSC@Cassini in Loiano, Italy; EFOSC2@NTT in La Silla, Chile; DOLORES@TNG in La Palma, Spain; CAFOS@2.2 m in Calar Alto, Spain; LaRuca@1.5 m in San Pedro Mártir, Mexico (see acknowledgements for more details).

  16. Web-based dynamic Delphi: a new survey instrument

    NASA Astrophysics Data System (ADS)

    Yao, JingTao; Liu, Wei-Ning

    2006-04-01

    We present a mathematical model for a dynamic Delphi survey method which takes advantages of Web technology. A comparative study on the performance of the conventional Delphi method and the dynamic Delphi instrument is conducted. It is suggested that a dynamic Delphi survey may form a consensus quickly. However, the result may not be robust due to the judgement leaking issues.

  17. Higher Education and Students with Orthopedic Disabilities: A Survey Instrument.

    ERIC Educational Resources Information Center

    Singh, Delar K.

    A survey instrument is presented that was used in a national survey of 160 colleges and universities to explore facilities and services to students with orthopedic disabilities. The survey contains 33 items that focus on the following areas: structural accessibility, academic accessibility, dorm-living, and recreational opportunities. The total…

  18. An Exploratory Survey of Information Requirements for Instrument Approach Charts

    DOT National Transportation Integrated Search

    1995-03-01

    This report documents a user centered survey and interview effort conducted to analyze the information content of : current Instrument Approach Plates (IAP). In the pilot opinion survey of approach chart information requirements, : respondents indica...

  19. International Energy Agency instrumented facilities survey for solar assisted low energy dwellings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1982-02-01

    Compiled are surveys outlining the instrumentation of 38 active and passive solar projects in 9 countries (Denmark, Italy, Japan, Netherlands, Sweden, Switzerland, United Kingdom, United States, and West Germany). After the surveys themselves are presented, the data are rearranged to compare answers from similar survey questions for each of the projects. These questions address building, solar system and instrumentation descriptions and meteorological, solar system and building system instrumentatation capabilities. (LEW)

  20. A field instrument for quantitative determination of beryllium by activation analysis

    USGS Publications Warehouse

    Vaughn, William W.; Wilson, E.E.; Ohm, J.M.

    1960-01-01

    A low-cost instrument has been developed for quantitative determinations of beryllium in the field by activation analysis. The instrument makes use of the gamma-neutron reaction between gammas emitted by an artificially radioactive source (Sb124) and beryllium as it occurs in nature. The instrument and power source are mounted in a panel-type vehicle. Samples are prepared by hand-crushing the rock to approximately ?-inch mesh size and smaller. Sample volumes are kept constant by means of a standard measuring cup. Instrument calibration, made by using standards of known BeO content, indicates the analyses are reproducible and accurate to within ? 0.25 percent BeO in the range from 1 to 20 percent BeO with a sample counting time of 5 minutes. Sensitivity of the instrument maybe increased somewhat by increasing the source size, the sample size, or by enlarging the cross-sectional area of the neutron-sensitive phosphor normal to the neutron flux.

  1. Quantitative imaging of the human upper airway: instrument design and clinical studies

    NASA Astrophysics Data System (ADS)

    Leigh, M. S.; Armstrong, J. J.; Paduch, A.; Sampson, D. D.; Walsh, J. H.; Hillman, D. R.; Eastwood, P. R.

    2006-08-01

    Imaging of the human upper airway is widely used in medicine, in both clinical practice and research. Common imaging modalities include video endoscopy, X-ray CT, and MRI. However, no current modality is both quantitative and safe to use for extended periods of time. Such a capability would be particularly valuable for sleep research, which is inherently reliant on long observation sessions. We have developed an instrument capable of quantitative imaging of the human upper airway, based on endoscopic optical coherence tomography. There are no dose limits for optical techniques, and the minimally invasive imaging probe is safe for use in overnight studies. We report on the design of the instrument and its use in preliminary clinical studies, and we present results from a range of initial experiments. The experiments show that the instrument is capable of imaging during sleep, and that it can record dynamic changes in airway size and shape. This information is useful for research into sleep disorders, and potentially for clinical diagnosis and therapies.

  2. Study Abroad Survey Instruments: A Comparison of Survey Types and Experiences

    ERIC Educational Resources Information Center

    Durrant, Marie Bradshaw; Dorius, Cassandra Rasmussen

    2007-01-01

    This study examines different survey instruments used to assess the experiences of U.S. study abroad participants. The intended audience is international and area study practitioners interested in assessing study abroad programs through postprogram interviews. An interview with the top 20 universities for number of students sent on study abroad…

  3. Quantitative Comparison of Tandem Mass Spectra Obtained on Various Instruments

    NASA Astrophysics Data System (ADS)

    Bazsó, Fanni Laura; Ozohanics, Oliver; Schlosser, Gitta; Ludányi, Krisztina; Vékey, Károly; Drahos, László

    2016-08-01

    The similarity between two tandem mass spectra, which were measured on different instruments, was compared quantitatively using the similarity index (SI), defined as the dot product of the square root of peak intensities in the respective spectra. This function was found to be useful for comparing energy-dependent tandem mass spectra obtained on various instruments. Spectral comparisons show the similarity index in a 2D "heat map", indicating which collision energy combinations result in similar spectra, and how good this agreement is. The results and methodology can be used in the pharma industry to design experiments and equipment well suited for good reproducibility. We suggest that to get good long-term reproducibility, it is best to adjust the collision energy to yield a spectrum very similar to a reference spectrum. It is likely to yield better results than using the same tuning file, which, for example, does not take into account that contamination of the ion source due to extended use may influence instrument tuning. The methodology may be used to characterize energy dependence on various instrument types, to optimize instrumentation, and to study the influence or correlation between various experimental parameters.

  4. Comparing NICU teamwork and safety climate across two commonly used survey instruments

    PubMed Central

    Profit, Jochen; Lee, Henry C; Sharek, Paul J; Kan, Peggy; Nisbet, Courtney C; Thomas, Eric J; Etchegaray, Jason M; Sexton, Bryan

    2016-01-01

    Background and objectives Measurement and our understanding of safety culture are still evolving. The objectives of this study were to assess variation in safety and teamwork climate and in the neonatal intensive care unit (NICU) setting, and compare measurement of safety culture scales using two different instruments (Safety Attitudes Questionnaire (SAQ) and Hospital Survey on Patient Safety Culture (HSOPSC)). Methods Cross-sectional survey study of a voluntary sample of 2073 (response rate 62.9%) health professionals in 44 NICUs. To compare survey instruments, we used Spearman's rank correlation coefficients. We also compared similar scales and items across the instruments using t tests and changes in quartile-level performance. Results We found significant variation across NICUs in safety and teamwork climate scales of SAQ and HSOPSC (p<0.001). Safety scales (safety climate and overall perception of safety) and teamwork scales (teamwork climate and teamwork within units) of the two instruments correlated strongly (safety r=0.72, p<0.001; teamwork r=0.67, p<0.001). However, the means and per cent agreements for all scale scores and even seemingly similar item scores were significantly different. In addition, comparisons of scale score quartiles between the two instruments revealed that half of the NICUs fell into different quartiles when translating between the instruments. Conclusions Large variation and opportunities for improvement in patient safety culture exist across NICUs. Important systematic differences exist between SAQ and HSOPSC such that these instruments should not be used interchangeably. PMID:26700545

  5. A Survey Instrument: General Educators and Students with Physical Disabilities.

    ERIC Educational Resources Information Center

    Singh, Delar K.

    A survey instrument is presented that is designed to explore the in-service training needs of general elementary and secondary teachers as they relate to learners with physical disabilities. It contains 75 items and takes 20-25 minutes to complete. The survey includes questions about the educator's teaching experience, teacher training in special…

  6. Using qualitative methods to develop a contextually tailored instrument: Lessons learned.

    PubMed

    Lee, Haeok; Kiang, Peter; Kim, Minjin; Semino-Asaro, Semira; Colten, Mary Ellen; Tang, Shirley S; Chea, Phala; Peou, Sonith; Grigg-Saito, Dorcas C

    2015-01-01

    To develop a population-specific instrument to inform hepatitis B virus (HBV) and human papilloma virus (HPV) prevention education and intervention based on data and evidence obtained from the targeted population of Khmer mothers reflecting their socio-cultural and health behaviors. The principles of community-based participatory research (CBPR) guided the development of a standardized survey interview. Four stages of development and testing of the survey instrument took place in order to inform the quantitative health survey used to collect data in stage five of the project. This article reports only on Stages 1-4. This process created a new quantitative measure of HBV and HPV prevention behavior based on the revised Network Episode Model and informed by the targeted population. The CBPR method facilitated the application and translation of abstract theoretical ideas of HBV and HPV prevention behavior into culturally-relevant words and expressions of Cambodian Americans (CAs). The design of an instrument development process that accounts for distinctive socio-cultural backgrounds of CA refugee/immigrant women provides a model for use in developing future health surveys that are intended to aid minority-serving health care professionals and researchers as well as targeted minority populations.

  7. Comparing NICU teamwork and safety climate across two commonly used survey instruments.

    PubMed

    Profit, Jochen; Lee, Henry C; Sharek, Paul J; Kan, Peggy; Nisbet, Courtney C; Thomas, Eric J; Etchegaray, Jason M; Sexton, Bryan

    2016-12-01

    Measurement and our understanding of safety culture are still evolving. The objectives of this study were to assess variation in safety and teamwork climate and in the neonatal intensive care unit (NICU) setting, and compare measurement of safety culture scales using two different instruments (Safety Attitudes Questionnaire (SAQ) and Hospital Survey on Patient Safety Culture (HSOPSC)). Cross-sectional survey study of a voluntary sample of 2073 (response rate 62.9%) health professionals in 44 NICUs. To compare survey instruments, we used Spearman's rank correlation coefficients. We also compared similar scales and items across the instruments using t tests and changes in quartile-level performance. We found significant variation across NICUs in safety and teamwork climate scales of SAQ and HSOPSC (p<0.001). Safety scales (safety climate and overall perception of safety) and teamwork scales (teamwork climate and teamwork within units) of the two instruments correlated strongly (safety r=0.72, p<0.001; teamwork r=0.67, p<0.001). However, the means and per cent agreements for all scale scores and even seemingly similar item scores were significantly different. In addition, comparisons of scale score quartiles between the two instruments revealed that half of the NICUs fell into different quartiles when translating between the instruments. Large variation and opportunities for improvement in patient safety culture exist across NICUs. Important systematic differences exist between SAQ and HSOPSC such that these instruments should not be used interchangeably. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  8. Food Consumption and Handling Survey for Quantitative Microbiological Consumer Phase Risk Assessments.

    PubMed

    Chardon, Jurgen; Swart, Arno

    2016-07-01

    In the consumer phase of a typical quantitative microbiological risk assessment (QMRA), mathematical equations identify data gaps. To acquire useful data we designed a food consumption and food handling survey (2,226 respondents) for QMRA applications that is especially aimed at obtaining quantitative data. For a broad spectrum of food products, the survey covered the following topics: processing status at retail, consumer storage, preparation, and consumption. Questions were designed to facilitate distribution fitting. In the statistical analysis, special attention was given to the selection of the most adequate distribution to describe the data. Bootstrap procedures were used to describe uncertainty. The final result was a coherent quantitative consumer phase food survey and parameter estimates for food handling and consumption practices in The Netherlands, including variation over individuals and uncertainty estimates.

  9. 10 CFR 34.65 - Records of radiation survey instruments.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Records of radiation survey instruments. 34.65 Section 34.65 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping Requirements § 34.65 Records of radiation...

  10. 10 CFR 34.65 - Records of radiation survey instruments.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Records of radiation survey instruments. 34.65 Section 34.65 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping Requirements § 34.65 Records of radiation...

  11. 10 CFR 34.65 - Records of radiation survey instruments.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Records of radiation survey instruments. 34.65 Section 34.65 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping Requirements § 34.65 Records of radiation...

  12. 10 CFR 34.65 - Records of radiation survey instruments.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Records of radiation survey instruments. 34.65 Section 34.65 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping Requirements § 34.65 Records of radiation...

  13. 10 CFR 34.65 - Records of radiation survey instruments.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Records of radiation survey instruments. 34.65 Section 34.65 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping Requirements § 34.65 Records of radiation...

  14. Space-borne survey instrument operations: lessons learned and new concepts for the Euclid NISP instrument

    NASA Astrophysics Data System (ADS)

    Valenziano, L.; Gregorio, A.; Butler, R. C.; Amiaux, J.; Bonoli, C.; Bortoletto, F.; Burigana, C.; Corcione, L.; Ealet, A.; Frailis, M.; Jahnke, K.; Ligori, S.; Maiorano, E.; Morgante, G.; Nicastro, L.; Pasian, F.; Riva, M.; Scaramella, R.; Schiavone, F.; Tavagnacco, D.; Toledo-Moreo, R.; Trifoglio, M.; Zacchei, A.; Zerbi, F. M.; Maciaszek, T.

    2012-09-01

    Euclid is the future ESA mission, mainly devoted to Cosmology. Like WMAP and Planck, it is a survey mission, to be launched in 2019 and injected in orbit far away from the Earth, for a nominal lifetime of 7 years. Euclid has two instruments on-board, the Visible Imager (VIS) and the Near- Infrared Spectro-Photometer (NISP). The NISP instrument includes cryogenic mechanisms, active thermal control, high-performance Data Processing Unit and requires periodic in-flight calibrations and instrument parameters monitoring. To fully exploit the capability of the NISP, a careful control of systematic effects is required. From previous experiments, we have built the concept of an integrated instrument development and verification approach, where the scientific, instrument and ground-segment expertise have strong interactions from the early phases of the project. In particular, we discuss the strong integration of test and calibration activities with the Ground Segment, starting from early pre-launch verification activities. We want to report here the expertise acquired by the Euclid team in previous missions, only citing the literature for detailed reference, and indicate how it is applied in the Euclid mission framework.

  15. Acousto-Optic Tunable Filter Spectroscopic Instrumentation for Quantitative Near-Ir Analysis of Organic Materials.

    NASA Astrophysics Data System (ADS)

    Eilert, Arnold James

    1995-01-01

    The utility of near-IR spectroscopy for routine quantitative analyses of a wide variety of compositional, chemical, or physical parameters of organic materials is well understood. It can be used for relatively fast and inexpensive non-destructive bulk material analysis before, during, and after processing. It has been demonstrated as being a particularly useful technique for numerous analytical applications in cereal (food and feed) science and industry. Further fulfillment of the potential of near-IR spectroscopic analysis, both in the process and laboratory environment, is reliant upon the development of instrumentation that is capable of meeting the challenges of increasingly difficult applications. One approach to the development of near-IR spectroscopic instrumentation that holds a great deal of promise is acousto-optic tunable filter (AOTF) technology. A combination of attributes offered by AOTF spectrometry, including speed, optical throughput, wavelength reproducibility, ruggedness (no -moving-parts operation) and flexibility, make it particularly desirable for numerous applications. A series of prototype (research model) acousto -optic tunable filter instruments were developed and tested in order to investigate the feasibility of the technology for quantitative near-IR spectrometry. Development included design, component procurement, assembly and/or configuration of the optical and electronic subsystems of which each functional spectrometer arrangement was comprised, as well as computer interfacing and acquisition/control software development. Investigation of this technology involved an evolution of several operational spectrometer systems, each of which offered improvements over its predecessor. Appropriate testing was conducted at various stages of development. Demonstrations of the potential applicability of our AOTF spectrometer to quantitative process monitoring or laboratory analysis of numerous organic substances, including food materials, were

  16. The Development of a Survey Instrument to Measure Transactional Distance in Secondary Blended Learning Environments

    ERIC Educational Resources Information Center

    Lane, Dennis Glenn

    2017-01-01

    The goal of this study was to develop a survey instrument to measure transactional distance in secondary blended learning environments. This study resulted in a 35-item survey instrument, the Blended Learning Assessment Scale of Transactional Distance (BLASTD), which was tested using a convenience sample of secondary students (n = 222) at a…

  17. Using qualitative methods to develop a contextually tailored instrument: Lessons learned

    PubMed Central

    Lee, Haeok; Kiang, Peter; Kim, Minjin; Semino-Asaro, Semira; Colten, Mary Ellen; Tang, Shirley S.; Chea, Phala; Peou, Sonith; Grigg-Saito, Dorcas C.

    2015-01-01

    Objective: To develop a population-specific instrument to inform hepatitis B virus (HBV) and human papilloma virus (HPV) prevention education and intervention based on data and evidence obtained from the targeted population of Khmer mothers reflecting their socio-cultural and health behaviors. Methods: The principles of community-based participatory research (CBPR) guided the development of a standardized survey interview. Four stages of development and testing of the survey instrument took place in order to inform the quantitative health survey used to collect data in stage five of the project. This article reports only on Stages 1-4. Results: This process created a new quantitative measure of HBV and HPV prevention behavior based on the revised Network Episode Model and informed by the targeted population. The CBPR method facilitated the application and translation of abstract theoretical ideas of HBV and HPV prevention behavior into culturally-relevant words and expressions of Cambodian Americans (CAs). Conclusions: The design of an instrument development process that accounts for distinctive socio-cultural backgrounds of CA refugee/immigrant women provides a model for use in developing future health surveys that are intended to aid minority-serving health care professionals and researchers as well as targeted minority populations. PMID:27981114

  18. Developing a Survey Instrument for Evaluating the Effectiveness of Data Management Training Materials

    NASA Astrophysics Data System (ADS)

    Hou, C. Y.; Soyka, H.; Hutchison, V.; Budden, A. E.

    2016-12-01

    Education and training resources that focus on best practices and guidelines for working with data such as: data management, data sharing, quality metadata creation, and maintenance for reuse, have vital importance not only to the users of Data Observation Network for Earth (DataONE), but also to the broader scientific, research, and academic communities. However, creating and maintaining relevant training/educational materials that remain sensitive and responsive to community needs is dependent upon careful evaluations of the current landscape in order to promote and support thoughtful development of new resources. Using DataONE's existing training/educational resources as the basis for this project, the authors have worked to develop an evaluation instrument that can be used to evaluate the effectiveness of data management training/education resources. The evaluation instrument is in the form of a digital questionnaire/survey. The evaluation instrument also includes the structure and content as recommended by the best practices/guidelines of questionnaire/survey design, based on a review of the literature. Additionally, the evaluation instrument can be customized to evaluate various training/education modalities and be implemented using a web-based questionnaire/survey platform. Finally, the evaluation instrument can be used for site-wide evaluation of DataONE teaching materials and resources, and once made publicly available and openly accessible, other organizations may also utilize the instrument. One key outcome of developing the evaluation instrument is to help in increasing the effectiveness of data management training/education resources across the Earth/Geoscience community. Through this presentation, the authors will provide the full background and motivations for creating an instrument for evaluating the effectiveness of data management training/education resources. The presentation will also discuss in detail the process and results of the current

  19. Development and validation of a survey instrument for assessing prescribers' perception of computerized drug-drug interaction alerts.

    PubMed

    Zheng, Kai; Fear, Kathleen; Chaffee, Bruce W; Zimmerman, Christopher R; Karls, Edward M; Gatwood, Justin D; Stevenson, James G; Pearlman, Mark D

    2011-12-01

    To develop a theoretically informed and empirically validated survey instrument for assessing prescribers' perception of computerized drug-drug interaction (DDI) alerts. The survey is grounded in the unified theory of acceptance and use of technology and an adapted accident causation model. Development of the instrument was also informed by a review of the extant literature on prescribers' attitude toward computerized medication safety alerts and common prescriber-provided reasons for overriding. To refine and validate the survey, we conducted a two-stage empirical validation study consisting of a pretest with a panel of domain experts followed by a field test among all eligible prescribers at our institution. The resulting survey instrument contains 28 questionnaire items assessing six theoretical dimensions: performance expectancy, effort expectancy, social influence, facilitating conditions, perceived fatigue, and perceived use behavior. Satisfactory results were obtained from the field validation; however, a few potential issues were also identified. We analyzed these issues accordingly and the results led to the final survey instrument as well as usage recommendations. High override rates of computerized medication safety alerts have been a prevalent problem. They are usually caused by, or manifested in, issues of poor end user acceptance. However, standardized research tools for assessing and understanding end users' perception are currently lacking, which inhibits knowledge accumulation and consequently forgoes improvement opportunities. The survey instrument presented in this paper may help fill this methodological gap. We developed and empirically validated a survey instrument that may be useful for future research on DDI alerts and other types of computerized medication safety alerts more generally.

  20. A survey of tools for the analysis of quantitative PCR (qPCR) data.

    PubMed

    Pabinger, Stephan; Rödiger, Stefan; Kriegner, Albert; Vierlinger, Klemens; Weinhäusel, Andreas

    2014-09-01

    Real-time quantitative polymerase-chain-reaction (qPCR) is a standard technique in most laboratories used for various applications in basic research. Analysis of qPCR data is a crucial part of the entire experiment, which has led to the development of a plethora of methods. The released tools either cover specific parts of the workflow or provide complete analysis solutions. Here, we surveyed 27 open-access software packages and tools for the analysis of qPCR data. The survey includes 8 Microsoft Windows, 5 web-based, 9 R-based and 5 tools from other platforms. Reviewed packages and tools support the analysis of different qPCR applications, such as RNA quantification, DNA methylation, genotyping, identification of copy number variations, and digital PCR. We report an overview of the functionality, features and specific requirements of the individual software tools, such as data exchange formats, availability of a graphical user interface, included procedures for graphical data presentation, and offered statistical methods. In addition, we provide an overview about quantification strategies, and report various applications of qPCR. Our comprehensive survey showed that most tools use their own file format and only a fraction of the currently existing tools support the standardized data exchange format RDML. To allow a more streamlined and comparable analysis of qPCR data, more vendors and tools need to adapt the standardized format to encourage the exchange of data between instrument software, analysis tools, and researchers.

  1. Weak Lensing from Space I: Instrumentation and Survey Strategy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rhodes, Jason; Refregier, Alexandre; Massey, Richard

    A wide field space-based imaging telescope is necessary to fully exploit the technique of observing dark matter via weak gravitational lensing. This first paper in a three part series outlines the survey strategies and relevant instrumental parameters for such a mission. As a concrete example of hardware design, we consider the proposed Supernova/Acceleration Probe (SNAP). Using SNAP engineering models, we quantify the major contributions to this telescope's Point Spread Function (PSF). These PSF contributions are relevant to any similar wide field space telescope. We further show that the PSF of SNAP or a similar telescope will be smaller than currentmore » ground-based PSFs, and more isotropic and stable over time than the PSF of the Hubble Space Telescope. We outline survey strategies for two different regimes - a ''wide'' 300 square degree survey and a ''deep'' 15 square degree survey that will accomplish various weak lensing goals including statistical studies and dark matter mapping.« less

  2. 76 FR 9637 - Proposed Information Collection (Veteran Suicide Prevention Online Quantitative Surveys) Activity...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-18

    ... Collection (Veteran Suicide Prevention Online Quantitative Surveys) Activity: Comment Request AGENCY... techniques or the use of other forms of information technology. Titles a. Veterans Online Survey, VA Form 10-0513: b. Veterans Family Online Survey, VA Form 10-0513a. c. Veterans Primary Care Provider Online...

  3. 76 FR 27384 - Agency Information Collection Activity (Veteran Suicide Prevention Online Quantitative Surveys...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-11

    ... Collection Activity (Veteran Suicide Prevention Online Quantitative Surveys) Under OMB Review AGENCY... techniques or the use of other forms of information technology. Titles a. Veterans Online Survey, VA Form 10-0513. b. Veterans Family Online Survey, VA Form 10-0513a. c. Veterans Primary Care Provider Online...

  4. A Systematic Review of Primary Care Safety Climate Survey Instruments: Their Origins, Psychometric Properties, Quality, and Usage.

    PubMed

    Curran, Ciara; Lydon, Sinéad; Kelly, Maureen; Murphy, Andrew; Walsh, Chloe; OʼConnor, Paul

    2018-06-01

    Safety climate (SC) measurement is a common and feasible method of proactive safety assessment in primary care. However, there is no consensus on which instrument is "best" to use. The aim of the study was to identify the origins, psychometric properties, quality, and SC domains measured by survey instruments used to assess SC in primary care settings. Systematic searches were conducted using Medline, Embase, CINAHL, and PsycInfo in February 2016. English-language, peer-reviewed studies that reported the development and/or use of a SC survey in a primary care setting were included. Two reviewers independently extracted data (survey characteristics, origins, and psychometric properties) from studies and applied the Quality Assessment Tool for Studies with Diverse Designs to assess methodological rigour. Safety climate domains within surveys were deductively analyzed and categorized into common healthcare SC themes. Seventeen SC surveys were identified, of which 16 had been adapted from 2 main U.S. hospital-based surveys. Only 1 survey was developed de novo for a primary care setting. The quantity and quality of psychometric testing varied considerably across the surveys. Management commitment to safety was the most frequently measured SC theme (87.5%). Workload was infrequently measured (25%). Valid and reliable instruments, which are context specific to the healthcare environment for intentional use, are essential to accurately assess SC. Key recommendations include further establishing the construct and criterion-related validity of existing instruments as opposed to developing additional surveys.

  5. Qualities of a Psychiatric Mentor: A Quantitative Singaporean Survey

    ERIC Educational Resources Information Center

    Tor, Phern-Chern; Goh, Lee-Gan; Ang, Yong-Guan; Lim, Leslie; Winslow, Rasaiah-Munidasa; Ng, Beng-Yeong; Wong, Sze-Tai; Ng, Tse-Pin; Kia, Ee-Heok

    2011-01-01

    Objective: Psychiatric mentors are an important part of the new, seamless training program in Singapore. There is a need to assess the qualities of a good psychiatric mentor vis-a-vis those of a good psychiatrist. Method: An anonymous survey was sent out to all psychiatry trainees and psychiatrists in Singapore to assess quantitatively the…

  6. Designing, Testing, and Validating an Attitudinal Survey on an Environmental Topic: A Groundwater Pollution Survey Instrument for Secondary School Students

    ERIC Educational Resources Information Center

    Lacosta-Gabari, Idoya; Fernandez-Manzanal, Rosario; Sanchez-Gonzalez, Dolores

    2009-01-01

    Research in environmental attitudes' assessment has significantly increased in recent years. The development of specific attitude scales for specific environmental problems has often been proposed. This paper describes the Groundwater Pollution Test (GPT), a 19-item survey instrument using a Likert-type scale. The survey has been used with…

  7. Ethical issues in palliative care for nursing homes: Development and testing of a survey instrument.

    PubMed

    Preshaw, Deborah Hl; McLaughlin, Dorry; Brazil, Kevin

    2018-02-01

    To develop and psychometrically assess a survey instrument identifying ethical issues during palliative care provision in nursing homes. Registered nurses and healthcare assistants have reported ethical issues in everyday palliative care provision. Identifying these issues provides evidence to inform practice development to support healthcare workers. Cross-sectional survey of Registered nurses and healthcare assistants in nursing homes in one region of the UK. A survey instrument, "Ethical issues in Palliative Care for Nursing homes", was developed through the findings of qualitative interviews with Registered nurses and healthcare assistants in nursing homes and a literature review. It was reviewed by an expert panel and piloted prior to implementation in a survey in 2015 with a convenience sample of 596 Registered nurses and healthcare assistants. Descriptive and exploratory factor analyses were used to assess the underlying structure of the Frequency and Distress Scales within the instrument. Analysis of 201 responses (response rate = 33.7%) revealed four factors for the Frequency Scale and five factors for the Distress Scale that comprise the Ethical issues in Palliative Care for Nursing homes. Factors common to both scales included "Processes of care," "Resident autonomy" and "Burdensome treatment." Additionally, the Frequency Scale included "Competency," and the Distress Scale included "Quality of care" and "Communication." The Ethical issues in Palliative Care for Nursing homes instrument has added to the palliative care knowledge base by considering the ethical issues experienced specifically by Registered nurses and healthcare assistants within the nursing home. This research offers preliminary evidence of the psychometric properties of the Ethical issues in Palliative Care for Nursing homes survey instrument. The two largest factors highlight the need to address the organisational aspects of caring and provide training in negotiating conflicting

  8. Identifying the Barriers to Using Games and Simulations in Education: Creating a Valid and Reliable Survey Instrument

    ERIC Educational Resources Information Center

    Justice, Lenora Jean

    2012-01-01

    The purpose of this study was to create a valid and reliable instrument to measure teacher perceived barriers to the adoption of games and simulations in instruction. Previous research, interviews with educators, a focus group, an expert review, and a think aloud protocol were used to design a survey instrument. After finalization, the survey was…

  9. The Hospice Environmental Survey (HES): Pilot Test of a New Measurement Instrument.

    ERIC Educational Resources Information Center

    Taylor, Jean H.; Perrill, Norman K.

    1988-01-01

    Describes development of the Hospice Environmental Survey (HES) to measure user's perception of the homelike atmosphere provided by a hospital inpatient unit called Hospice House. Presents the HES instrument, methodology, and pilot study data. (Author/NB)

  10. A survey of mass analyzers. [characteristics and features of various instruments and techniques

    NASA Technical Reports Server (NTRS)

    Moore, W. W., Jr.; Tashbar, P. W.

    1973-01-01

    With the increasing applications of mass spectrometry technology to diverse services areas, a need has developed for a consolidated survey of the essential characteristics and features of the various instruments and techniques. This report is one approach to satisfying this need. Information has been collected and consolidated into a format which includes for each approach: (1) a general technique description, (2) instrument features information, and (3) a summary of pertinent advantages and disadvantages. With this information, the potential mass spectrometer user should be able to more efficiently select the most appropriate instrument.

  11. The quantitative measurement of organizational culture in health care: a review of the available instruments.

    PubMed

    Scott, Tim; Mannion, Russell; Davies, Huw; Marshall, Martin

    2003-06-01

    To review the quantitative instruments available to health service researchers who want to measure culture and cultural change. A literature search was conducted using Medline, Cinahl, Helmis, Psychlit, Dhdata, and the database of the King's Fund in London for articles published up to June 2001, using the phrase "organizational culture." In addition, all citations and the gray literature were reviewed and advice was sought from experts in the field to identify instruments not found on the electronic databases. The search focused on instruments used to quantify culture with a track record, or potential for use, in health care settings. For each instrument we examined the cultural dimensions addressed, the number of items for each questionnaire, the measurement scale adopted, examples of studies that had used the tool, the scientific properties of the instrument, and its strengths and limitations. Thirteen instruments were found that satisfied our inclusion criteria, of which nine have a track record in studies involving health care organizations. The instruments varied considerably in terms of their grounding in theory, format, length, scope, and scientific properties. A range of instruments with differing characteristics are available to researchers interested in organizational culture, all of which have limitations in terms of their scope, ease of use, or scientific properties. The choice of instrument should be determined by how organizational culture is conceptualized by the research team, the purpose of the investigation, intended use of the results, and availability of resources.

  12. Developing, testing, and implementing a survey of scientist mentoring teachers as part of an RET: The GABI RET mentor survey.

    NASA Astrophysics Data System (ADS)

    Davey, B.

    2017-12-01

    The impacts of mentoring in education have been well established. Mentors have a large impact on their mentees and have been show to affect mentee attitudes towards learning, interest in subjects, future success, and more. While mentoring has a well-documented impact on the mentees, mentoring also has an impact on the mentors themselves. However, little has been studied empirically about these impacts. When we looked for a validated instrument that measured the impact of mentoring on the scientists working with the teachers, we found many anecdotal reports but no instruments that meet our specific needs. To this end, we developed, tested, and implemented our own instrument for measuring the impacts of mentoring on our scientist mentors. Our instrument contained both quantitative and qualitative items designed to reveal the effects of mentoring in two areas: 1) cognitive domain (mentoring, teaching, understanding K-12) and 2) affective domain (professional, personal, participation). We first shared our survey with experts in survey development and mentoring, gathered their feedback, and incorporated their suggestions into our instrument. We then had a subsection of our mentors complete the survey and then complete it again three to four days later (test-retest). Our survey has a high correlation for the test-retest quantitative items (0.93) and a high correlation (0.90) between the three reviewers of the qualitative items. From our findings, we feel we have a validated instrument (face, content, and contruct validity) that answers our research questions reliably. Our contribution to the study of mentoring of science teachers reveals a broad range of impacts on the mentors themselves including an improved understanding of the challenges of classroom teaching, a recognition of the importance of scientists working with science teachers, an enhanced ability to communicate their research and findings, and an increased interest and excitement for their own work.

  13. Hydrologic Instrumentation Facility of the U.S. Geological Survey, annual report for fiscal year 1993

    USGS Publications Warehouse

    Latkovich, V.J.; Tracey, Debra C.

    1994-01-01

    The Hydrologic lnstrumentation Facility (HIF) of the U.S. Geological Survey (USGS) has nationwide responsibility for all aspects of hydrologic field instrumentation in support of Survey data-collection programs. Each year the HIF publishes a report to inform Water Resources Division (WRD) personnel of progress made by the HIF in fulfilling its mission to improve instrumentation services to the Division. The report for fiscal year 1993 (FY93) describes the activities of the HIF, including major accomplish- ments for the year; personnel actions; active projects (reported by section--Technical Services Section, Administrative Services Section, Field Coordination, Applications and Development Section, Test and Evaluation Section, Field Service and Supply Section); and planned activities for the coming year. Also presented in the appendixes are detailed listings of the memberships of the Instrumentation Committee and the Instrumentation Technical Advisory Subcommittee; district, sub- district, and field office visits by HIF personnel; professional and technical meetings attended by HIF personnel; vendor visits; and reports prepared by HIF personnel.

  14. The Quantitative Measurement of Organizational Culture in Health Care: A Review of the Available Instruments

    PubMed Central

    Scott, Tim; Mannion, Russell; Davies, Huw; Marshall, Martin

    2003-01-01

    Objective To review the quantitative instruments available to health service researchers who want to measure culture and cultural change. Data Sources A literature search was conducted using Medline, Cinahl, Helmis, Psychlit, Dhdata, and the database of the King's Fund in London for articles published up to June 2001, using the phrase “organizational culture.” In addition, all citations and the gray literature were reviewed and advice was sought from experts in the field to identify instruments not found on the electronic databases. The search focused on instruments used to quantify culture with a track record, or potential for use, in health care settings. Data Extraction For each instrument we examined the cultural dimensions addressed, the number of items for each questionnaire, the measurement scale adopted, examples of studies that had used the tool, the scientific properties of the instrument, and its strengths and limitations. Principal Findings Thirteen instruments were found that satisfied our inclusion criteria, of which nine have a track record in studies involving health care organizations. The instruments varied considerably in terms of their grounding in theory, format, length, scope, and scientific properties. Conclusions A range of instruments with differing characteristics are available to researchers interested in organizational culture, all of which have limitations in terms of their scope, ease of use, or scientific properties. The choice of instrument should be determined by how organizational culture is conceptualized by the research team, the purpose of the investigation, intended use of the results, and availability of resources. PMID:12822919

  15. Quantitative three-dimensional low-speed wake surveys

    NASA Technical Reports Server (NTRS)

    Brune, G. W.

    1992-01-01

    Theoretical and practical aspects of conducting three-dimensional wake measurements in large wind tunnels are reviewed with emphasis on applications in low-speed aerodynamics. Such quantitative wake surveys furnish separate values for the components of drag, such as profile drag and induced drag, but also measure lift without the use of a balance. In addition to global data, details of the wake flowfield as well as spanwise distributions of lift and drag are obtained. The paper demonstrates the value of this measurement technique using data from wake measurements conducted by Boeing on a variety of low-speed configurations including the complex high-lift system of a transport aircraft.

  16. Survey of Instrumentation for the Measurement of Stratospheric Trace Gases and Particulates (CIAP)

    DOT National Transportation Integrated Search

    1971-11-01

    A survey was conducted to determine the applicability of presently available instrumentation to the direct and/or remote measure of trace gases and particulates within the stratosphere. Consideration was also given to techniques under development whe...

  17. Examining Stress in Graduate Assistants: Combining Qualitative and Quantitative Survey Methods

    ERIC Educational Resources Information Center

    Mazzola, Joseph J.; Walker, Erin J.; Shockley, Kristen M.; Spector, Paul E.

    2011-01-01

    The aim of this study was to employ qualitative and quantitative survey methods in a concurrent mixed model design to assess stressors and strains in graduate assistants. The stressors most frequently reported qualitatively were work overload, interpersonal conflict, and organizational constraints; the most frequently reported psychological…

  18. Effects of instrument imperfections on quantitative scanning transmission electron microscopy.

    PubMed

    Krause, Florian F; Schowalter, Marco; Grieb, Tim; Müller-Caspary, Knut; Mehrtens, Thorsten; Rosenauer, Andreas

    2016-02-01

    Several instrumental imperfections of transmission electron microscopes are characterized and their effects on the results of quantitative scanning electron microscopy (STEM) are investigated and quantified using simulations. Methods to either avoid influences of these imperfections during acquisition or to include them in reference calculations are proposed. Particularly, distortions inflicted on the diffraction pattern by an image-aberration corrector can cause severe errors of more than 20% if not accounted for. A procedure for their measurement is proposed here. Furthermore, afterglow phenomena and nonlinear behavior of the detector itself can lead to incorrect normalization of measured intensities. Single electrons accidentally impinging on the detector are another source of error but can also be exploited for threshold-less calibration of STEM images to absolute dose, incident beam current determination and measurement of the detector sensitivity. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. The Communities Advancing Resilience Toolkit (CART): development of a survey instrument to assess community resilience.

    PubMed

    Pfefferbaum, Rose L; Neas, Barbara R; Pfefferbaum, Betty; Norris, Fran H; Van Horn, Richard L

    2013-01-01

    While building community resilience to disasters is becoming an important strategy in emergency management, this is a new field of research with few available instruments for assessing community resilience. This article describes the development of the Communities Advancing Resilience Toolkit (CART) survey instrument. CART is a community intervention designed to enhance community resilience to disasters, in part, by engaging communities in measuring it. The survey instrument, originally based on community capacity and related literature and on key informant input, was refined through a series of four field tests. Community organizations worked with researchers in a participatory action process that provided access to samples and helped to guide the research. Exploratory factor analysis performed after each field test led to the identification of four interrelated constructs (also called domains) which represent the foundation for CART Connection and Caring, Resources, Transformative Potential, and Disaster Management. This model was confirmed using confirmatory factor analysis on two community samples. The CART survey can provide data for organizations and communities interested in assessing a community's resilience to disasters. Baseline data, preferably collected pre disaster can be compared to data collected post disaster and/or post intervention.

  20. Nuclear medicine and imaging research (Instrumentation and quantitative methods of evaluation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beck, R.N.; Cooper, M.D.

    1989-09-01

    This program addresses the problems involving the basic science and technology underlying the physical and conceptual tools of radioactive tracer methodology as they relate to the measurement of structural and functional parameters of physiologic importance in health and disease. The principal tool is quantitative radionuclide imaging. The overall objective of this program is to further the development and transfer of radiotracer methodology from basic theory to routine clinical practice in order that individual patients and society as a whole will receive the maximum net benefit from the new knowledge gained. The focus of the research is on the development ofmore » new instruments and radiopharmaceuticals, and the evaluation of these through the phase of clinical feasibility.« less

  1. Use of Standardized Assessment Instruments by Marital and Family Therapists: A Survey.

    ERIC Educational Resources Information Center

    Boughner, Shelly R.; And Others

    1994-01-01

    Surveyed 598 marriage/family practitioners to examine use of standardized assessment instruments in practice. Responses from 188 clinicians who reported use of tests revealed that 147 different standardized tests were used in marriage and family therapy practice. Test use was most frequent for treatment planning purposes, except in premarital area…

  2. Quantitative assessment of apical debris extrusion and intracanal debris in the apical third, using hand instrumentation and three rotary instrumentation systems.

    PubMed

    H K, Sowmya; T S, Subhash; Goel, Beena Rani; T N, Nandini; Bhandi, Shilpa H

    2014-02-01

    Decreased apical extrusion of debris and apical one third debris have strong implications for decreased incidence of postoperative inflammation and pain. Thus, the aim of this study was to assess quantitatively the apical extrusion of debris and intracanal debris in the apical third during root canal instrumentation using hand and three different types of rotary instruments. Sixty freshly extracted single rooted human teeth were randomly divided into four groups. Canal preparation was done using step-back with hand instrumentation, crown-down technique with respect to ProTaper and K3, and hybrid technique with LightSpeed LSX. Irrigation was done with NaOCl, EDTA, and normal saline and for final irrigation, EndoVac system was used. The apically extruded debris was collected on the pre-weighed Millipore plastic filter disk and weighed using microbalance. The teeth were submitted to the histological processing. Sections from the apical third were analyzed by a trinocular research microscope that was coupled to a computer where the images were captured and analyzed using image proplus V4.1.0.0 software. The mean weight of extruded debris for each group and intracanal debris in the root canal was statistically analyzed by a Kruskal-Wallis one-way analysis of variance and Mann-Whitney U test. The result showed that, hand instrumentation using K files showed the highest amount of debris extrusion apically when compared to ProTaper, K3 and LightSpeed LSX. The result also showed that there was no statistically significant difference between the groups in relation to presence of intracanal debris in the apical one third. Based on the results, all instrumentation techniques produced debris extrusion. The engine driven Ni-Ti systems extruded significantly less apical debris than hand instrumentation. There was no statistically significant difference between the groups in relation to presence of intracanal debris in the apical one third.

  3. [The quantitative recovery of microbes during testing of disinfectants for instruments].

    PubMed

    Höller, C; Gundermann, K O

    1990-02-01

    The efficacy of a disinfectant can only be determined exactly, when quantitative as well as qualitative tests are being performed. Aim of this study was to ascertain whether the earlier published method of a germ carrier test could be applied also to the testing of disinfectants for instruments. Rubber tubes of 1 cm length were used as germ carriers, Staph. aureus, Pseud. aerug., Proteus mir., E. coli and Cand. alb. as test organisms. The culture media were CASO-agar and -broth, latter containing 20% defibrinated sheep blood in some experiments. Two disinfectants on aldehyde-basis and one disinfectant on phenol-basis and on biguanide-basis, respectively, were used for the disinfectant tests. The rubber tubes were contaminated with bacterial suspension, dried upright on sterile filters and then put into 10 ml CASO-broth. After high speed vortexing of the germ carriers the bacterial count was determined. Following factors that were believed to probably having an influence on the recovery rate of bacteria were investigated: 1. the amount of fluid staying on the rubber tubes; 2. the drying time; 3. the vortexing time; 4. repeated vortexing; 5. variations of the initial concentration of bacteria on the rubber tubes; 6. addition of inactivating substances. ad 1. The mean amount of fluid staying on the tubes was 0.0056 g. ad 2. Drying times longer than 30 to 60 min resulted partly in considerably lower bacterial counts. ad. 3. and 4. Neither extension of vortexing time nor repeated vortexing of the same germ carrier could raise the recovery rate of bacteria. ad 5. Higher initial concentration of bacteria on the rubber tubes could not be achieved. The recovery rate of bacteria was reliable even when the initial bacterial concentration was low. ad 6. Addition of inactivating substances to the CASO-broth had no influence on the recovery rate of bacteria. The test method was checked by testing four disinfectants for instruments and proved itself a good and reliable

  4. Organizational member involvement in physical activity coalitions across the United States: development and testing of a novel survey instrument for assessing coalition functioning.

    PubMed

    Bornstein, Daniel B; Pate, Russell R; Beets, Michael W; Saunders, Ruth P; Blair, Steven N

    2015-06-01

    Coalitions are often composed of member organizations. Member involvement is thought to be associated with coalition success. No instrument currently exists for evaluating organizational member involvement in physical activity coalitions. This study aimed to develop a survey instrument for evaluating organizational member involvement in physical activity coalitions. The study was carried out in three phases: (a) developing a draft survey, (b) assessing the content validity of the draft survey, and (c) assessing the underlying factor structure, reliability, and validity of the survey. A cross-sectional design was employed. In Phase 1, a team of experts in survey development produced a draft survey. In Phase 2, the content validity of the draft survey was evaluated by a panel of individuals with expertise in physical activity coalitions. In Phase 3, the survey was administered to 120 individuals on local-, state-, and national-level physical activity coalitions. Responses were subjected to an exploratory factor analysis in order to determine the survey's underlying factor structure, reliability, and validity. Phases 1 and 2yielded a survey instrument with demonstrated content validity. Phase 3 yielded a three-factor model with three subscales: Strategic Alignment, Organizational Alignment, and Providing Input. Each subscale demonstrated high internal consistency reliability and construct validity. The survey instrument developed here demonstrated sound psychometric properties and provides new insight into organizational member involvement in physical activity coalitions. This instrument may be an important tool in developing a more complete picture of coalition functioning in physical activity coalitions specifically and health-based coalitions overall. © 2014 Society for Public Health Education.

  5. Measuring patient trust in telemedicine services: Development of a survey instrument and its validation for an anticoagulation web-service.

    PubMed

    Velsen, Lex van; Tabak, Monique; Hermens, Hermie

    2017-01-01

    For many eServices, end-user trust is a crucial prerequisite for use. For the telemedicine context however, knowledge about the coming about and measurement of end-user trust is scarce. To develop and validate the PAtient Trust Assessment Tool (PATAT): a survey instrument to quantitatively assess patient trust in a telemedicine service. Informed by focus groups, we developed a survey that includes measurement scales for the following factors: trust in the care organization, care professional, treatment, and technology, as well as a scale that assesses a holistic view on trust in the telemedicine service. The survey was completed by 795 patients that use a telemedicine application to manage their anticoagulation treatment. Data were analyzed by means of Partial Least Squares Structural Equation Modeling (PLS-SEM). The measurement model yielded good to excellent quality measures, after the removal of one item. The causal model resulted in high explained variance (R 2 =0.68). Trust in healthcare professionals and the treatment had a small effect on overall trust, while trust in the technology displayed a large effect. Trust in the care organization did not result in a significant effect on overall trust. The PATAT is a valid means to assess patient trust in a telemedicine service and can be used to benchmark such a service or to elicit redesign input. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Quantitative Assessment of Apical Debris Extrusion and Intracanal Debris in the Apical Third, Using Hand Instrumentation and Three Rotary Instrumentation Systems

    PubMed Central

    H.K., Sowmya; T.S., Subhash; Goel, Beena Rani; T.N., Nandini; Bhandi, Shilpa H.

    2014-01-01

    Introduction: Decreased apical extrusion of debris and apical one third debris have strong implications for decreased incidence of postoperative inflammation and pain. Thus, the aim of this study was to assess quantitatively the apical extrusion of debris and intracanal debris in the apical third during root canal instrumentation using hand and three different types of rotary instruments. Methodology: Sixty freshly extracted single rooted human teeth were randomly divided into four groups. Canal preparation was done using step-back with hand instrumentation, crown-down technique with respect to ProTaper and K3, and hybrid technique with LightSpeed LSX. Irrigation was done with NaOCl, EDTA, and normal saline and for final irrigation, EndoVac system was used. The apically extruded debris was collected on the pre-weighed Millipore plastic filter disk and weighed using microbalance. The teeth were submitted to the histological processing. Sections from the apical third were analyzed by a trinocular research microscope that was coupled to a computer where the images were captured and analyzed using image proplus V4.1.0.0 software. The mean weight of extruded debris for each group and intracanal debris in the root canal was statistically analyzed by a Kruskal-Wallis one-way analysis of variance and Mann-Whitney U test. Results: The result showed that, hand instrumentation using K files showed the highest amount of debris extrusion apically when compared to ProTaper, K3 and LightSpeed LSX. The result also showed that there was no statistically significant difference between the groups in relation to presence of intracanal debris in the apical one third. Conclusion: Based on the results, all instrumentation techniques produced debris extrusion. The engine driven Ni-Ti systems extruded significantly less apical debris than hand instrumentation. There was no statistically significant difference between the groups in relation to presence of intracanal debris in the apical one

  7. The Eastland Prostate Cancer Survey: instrument development and psychometric testing.

    PubMed

    Eastland, Taryn Y; Dancy, Barbara L

    2013-03-01

    African-American (AA) women could be instrumental in communicating positive prostate screening behavior to the significant males in their lives. However, little is known about AA women's prostate cancer attitudes, perceived behavioral control, subjective norms, intentions, behaviors, and knowledge regarding prostate cancer screening. This study describes the development and psychometric testing of the Eastland Prostate Cancer Survey (EPCS). A nonexperimental, correlational study with 200 AA women was used to test the psychometric properties of the six-subscale EPCS with 66 items. Construct validity, internal consistency, and test-retest reliability for the EPCS were acceptable and resulted in an eight-subscale EPCS with 56 items. Cronbach's alphas for the subscales ranged from 0.69 to 0.92. The EPCS is a culturally sensitive, gender-relevant instrument that could be used by community health providers to develop community health programs aimed at engaging AA women in the promotion of prostate cancer screening for AA men.

  8. Developing a theoretical model and questionnaire survey instrument to measure the success of electronic health records in residential aged care.

    PubMed

    Yu, Ping; Qian, Siyu

    2018-01-01

    Electronic health records (EHR) are introduced into healthcare organizations worldwide to improve patient safety, healthcare quality and efficiency. A rigorous evaluation of this technology is important to reduce potential negative effects on patient and staff, to provide decision makers with accurate information for system improvement and to ensure return on investment. Therefore, this study develops a theoretical model and questionnaire survey instrument to assess the success of organizational EHR in routine use from the viewpoint of nursing staff in residential aged care homes. The proposed research model incorporates six variables in the reformulated DeLone and McLean information systems success model: system quality, information quality, service quality, use, user satisfaction and net benefits. Two variables training and self-efficacy were also incorporated into the model. A questionnaire survey instrument was designed to measure the eight variables in the model. After a pilot test, the measurement scale was used to collect data from 243 nursing staff members in 10 residential aged care homes belonging to three management groups in Australia. Partial least squares path modeling was conducted to validate the model. The validated EHR systems success model predicts the impact of the four antecedent variables-training, self-efficacy, system quality and information quality-on the net benefits, the indicator of EHR systems success, through the intermittent variables use and user satisfaction. A 24-item measurement scale was developed to quantitatively evaluate the performance of an EHR system. The parsimonious EHR systems success model and the measurement scale can be used to benchmark EHR systems success across organizations and units and over time.

  9. Creation and use of a survey instrument for comparing mobile computing devices.

    PubMed

    Macri, Jennifer M; Lee, Paul P; Silvey, Garry M; Lobach, David F

    2005-01-01

    Both personal digital assistants (PDAs) and tablet computers have emerged to facilitate data collection at the point of care. However, little research has been reported comparing these mobile computing devices in specific care settings. In this study we present an approach for comparing functionally identical applications on a Palm operating system-based PDA and a Windows-based tablet computer for point-of-care documentation of clinical observations by eye care professionals when caring for patients with diabetes. Eye-care professionals compared the devices through focus group sessions and through validated usability surveys. This poster describes the development and use of the survey instrument used for comparing mobile computing devices.

  10. A Survey on Nickel Titanium Rotary Instruments and their Usage Techniques by Endodontists in India.

    PubMed

    Patil, Thimmanagowda N; Saraf, Prahlad A; Penukonda, Raghavendra; Vanaki, Sneha S; Kamatagi, Laxmikant

    2017-05-01

    The preference and usage of nickel titanium rotary instruments varies from individual to individual based on their technique, experience with the rotary systems and the clinical situation. Very limited information is available to explain the adoption of changing concepts with respect to nickel titanium rotary instruments pertaining to the endodontists in India. The aim of this study was to conduct a questionnaire survey to acquire the knowledge concerning different NiTi rotary instruments and their usage techniques by endodontists in India. A Survey questionnaire was designed which consisted of 32 questions regarding designation, demographics, experience with rotary instruments, usage of different file systems, usage techniques, frequency of reuse, occurrence of file fracture, reasons and their management was distributed by hand in the national postgraduate convention and also disseminated via electronic medium to 400 and 600 endodontists respectively. Information was collected from each individual to gain insight into the experiences and beliefs of endodontists concerning the new endodontic technology of rotary NiTi instrumentation based on their clinical experience with the rotary systems. The questions were designed to ascertain the problems, patterns of use and to identify areas of perceived or potential concern regarding the rotary instruments and the data acquired was statistically evaluated using Fisher's-exact test and the Chi-Square test. Overall 63.8% (638) endodontists responded. ProTaper was one of the most commonly used file system followed by M two and ProTaper Next. There was a significant co relation between the years of experience and the file re use frequency, preparation technique, file separation, management of file separation. A large number of Endodontists prefer to reuse the rotary NiTi instruments. As there was an increase in the experience, the incidence of file separation reduced with increasing number of re use frequency and with

  11. Temperature performance of portable radiation survey instruments used for environmental monitoring and clean-up activities in Fukushima

    NASA Astrophysics Data System (ADS)

    Saegusa, Jun; Yanagisawa, Kayo; Hasumi, Atsushi; Shimizu, Takenori; Uchita, Yoshiaki

    2017-08-01

    Following the Fukushima Dai-ichi Nuclear Power Plant accident in March 2011, extensive radiation monitoring and environmental clean-up activities have been conducted throughout the Fukushima region. Outside air temperatures there reach 40 °C in summer and -20 °C in winter, which are beyond the quoted operational range of many radiation survey instruments. Herein, temperature performance of four types of portable Japanese radiation survey instruments widely used in Fukushima was experimentally investigated using a temperature-controlled chamber. They included two ionization chamber type instruments, Fuji NHA1 and Aloka ICS-323C, and two NaI(Tl) scintillation type ones, Fuji NHC7 and Aloka TCS-172B. Experimental results showed significantly diverse characteristics on the temperature dependences from one type of instrument to another. For example, NHA1 overestimated the ambient dose-equivalent rate by as much as 17% at -30 °C and 10% at 40 °C, whereas the TCS-172B readings underestimated the rate by 30% at -30 °C and 7% at 40 °C.

  12. A Nominal Balloon Instrument Payload to Address Questions from the Planetary Decadal Survey

    NASA Astrophysics Data System (ADS)

    Young, Eliot; Kremic, Tibor; Dankanich, John

    The Planetary Science Decadal Survey (entitled "Visions and Voyages for Planetary Science in the Decade 2013 - 2022", available online at https://solarsystem.nasa.gov/2013decadal/) serves as a roadmap for activities to be pursued by the Planetary Science Division of NASA's Science Mission Directorate. This document outlines roughly 200 key research areas and questions in chapters covering different parts of the solar system (e.g., Mars, Small Bodies, etc.). We have reviewed the Decadal Survey to assess whether any of the key questions can be addressed by high altitude balloon-borne payloads. Although some questions can only be answered by in situ experiments, we found that approximately one quarter of the key questions were well suited to balloon payloads. In many of those cases, balloons were competitive or superior to other existing facilities, including HST, SOFIA or Keck telescopes. We will present specific telescope and instrument bench designs that are capable of addressing key questions in the Decadal Survey. The instrument bench takes advantage of two of the main benefits of high-altitude observations: diffraction-limited imaging in visible and UV wavelengths and unobstructed spectroscopy in near-IR (1 - 5 microns) wavelengths. Our optical prescription produces diffraction-limited PSFs in both visible and IR beams. We will discuss pointing and thermal stability, two of the main challenges facing a balloon-borne telescope.

  13. Using an innovative mixed method methodology to investigate the appropriateness of a quantitative instrument in an African context: Antiretroviral treatment and quality of life.

    PubMed

    Greeff, Minrie; Chepuka, Lignet M; Chilemba, Winnie; Chimwaza, Angela F; Kululanga, Lucy I; Kgositau, Mabedi; Manyedi, Eva; Shaibu, Sheila; Wright, Susan C D

    2014-01-01

    The relationship between quality of life (QoL) and antiretroviral treatment (ART) has mainly been studied using quantitative scales often not appropriate for use in other contexts and without taking peoples' lived experiences into consideration. Sub-Saharan Africa has the highest incidence of HIV and AIDS yet there is paucity in research done on QoL. This research report is intended to give an account of the use of a mixed method convergent parallel design as a novice approach to evaluate an instrument's context specificity, appropriateness and usefulness in another context for which it was designed. Data were collected through a qualitative exploration of the experiences of QoL of people living with HIV or AIDS (PLHA) in Africa since being on ART, as well as the quantitative measurements obtained from the HIV/AIDS-targeted quality of life (HAT-QoL) instrument. This study was conducted in three African countries. Permission and ethical approval to conduct the study were obtained. Purposive voluntary sampling was used to recruit PLHA through mediators working in community-based HIV/AIDS organisations and health clinics. Interviews were analysed through open coding and the quantitative data through descriptive statistics and the Cronbach's alpha coefficient. A much wider range and richness of experiences were expressed than measured by the HAT-QoL instrument. Although an effective instrument for use in the USA, it was found not to be sensitive, appropriate and useful in an African context in its present form. The recommendations focus on adapting the instrument using the data from the in-depth interviews or to develop a context-sensitive instrument that could measure QoL of PLHA in Africa.

  14. A Quantitative Evaluation of Dissolved Oxygen Instrumentation

    NASA Technical Reports Server (NTRS)

    Pijanowski, Barbara S.

    1971-01-01

    The implications of the presence of dissolved oxygen in water are discussed in terms of its deleterious or beneficial effects, depending on the functional consequences to those affected, e.g., the industrialist, the oceanographer, and the ecologist. The paper is devoted primarily to an examination of the performance of five commercially available dissolved oxygen meters. The design of each is briefly reviewed and ease or difficulty of use in the field described. Specifically, the evaluation program treated a number of parameters and user considerations including an initial check and trial calibration for each instrument and a discussion of the measurement methodology employed. Detailed test results are given relating to the effects of primary power variation, water-flow sensitivity, response time, relative accuracy of dissolved-oxygen readout, temperature accuracy (for those instruments which included this feature), error and repeatability, stability, pressure and other environmental effects, and test results obtained in the field. Overall instrument performance is summarized comparatively by chart.

  15. The Acquisition Age of Quantitative Concepts of Children From Three to Six Years Old

    ERIC Educational Resources Information Center

    Kraner, Robert E.

    1978-01-01

    A criterion-referenced measuring instrument was developed from a national survey of quantitative skills/concepts required by entering first grade students and individually administered to 273 children three to six and one-half years of age. By comparing mastery age of each of the 153 skills/concepts, sequential patterns of development were made…

  16. Focus Groups in Elderly Ophthalmologic Patients: Setting the Stage for Quantitative Preference Elicitation.

    PubMed

    Danner, Marion; Vennedey, Vera; Hiligsmann, Mickaël; Fauser, Sascha; Stock, Stephanie

    2016-02-01

    Patients suffering from age-related macular degeneration (AMD) are rarely actively involved in decision-making, despite facing preference-sensitive treatment decisions. This paper presents a qualitative study to prepare quantitative preference elicitation in AMD patients. The aims of this study were (1) to gain familiarity with and learn about the special requirements of the AMD patient population for quantitative data collection; and (2) to select/refine patient-relevant treatment attributes and levels, and gain insights into preference structures. Semi-structured focus group interviews were performed. An interview guide including preselected categories in the form of seven potentially patient-relevant treatment attributes was followed. To identify the most patient-relevant treatment attributes, a ranking exercise was performed. Deductive content analyses were done by two independent reviewers for each attribute to derive subcategories (potential levels of attributes) and depict preference trends. The focus group interviews included 21 patients. The interviews revealed that quantitative preference surveys in this population will have to be interviewer assisted to make the survey feasible for patients. The five most patient-relevant attributes were the effect on visual function [ranking score (RS): 139], injection frequency (RS: 101), approval status (RS: 83), side effects (RS: 79), and monitoring frequency (RS: 76). Attribute and level refinement was based on patients' statements. Preference trends and dependencies between attributes informed the quantitative instrument design. This study suggests that qualitative research is a very helpful step to prepare the design and administration of quantitative preference elicitation instruments. It especially facilitated familiarization with the target population and its preferences, and it supported attribute/level refinement.

  17. Developing a theoretical model and questionnaire survey instrument to measure the success of electronic health records in residential aged care

    PubMed Central

    Yu, Ping; Qian, Siyu

    2018-01-01

    Electronic health records (EHR) are introduced into healthcare organizations worldwide to improve patient safety, healthcare quality and efficiency. A rigorous evaluation of this technology is important to reduce potential negative effects on patient and staff, to provide decision makers with accurate information for system improvement and to ensure return on investment. Therefore, this study develops a theoretical model and questionnaire survey instrument to assess the success of organizational EHR in routine use from the viewpoint of nursing staff in residential aged care homes. The proposed research model incorporates six variables in the reformulated DeLone and McLean information systems success model: system quality, information quality, service quality, use, user satisfaction and net benefits. Two variables training and self-efficacy were also incorporated into the model. A questionnaire survey instrument was designed to measure the eight variables in the model. After a pilot test, the measurement scale was used to collect data from 243 nursing staff members in 10 residential aged care homes belonging to three management groups in Australia. Partial least squares path modeling was conducted to validate the model. The validated EHR systems success model predicts the impact of the four antecedent variables—training, self-efficacy, system quality and information quality—on the net benefits, the indicator of EHR systems success, through the intermittent variables use and user satisfaction. A 24-item measurement scale was developed to quantitatively evaluate the performance of an EHR system. The parsimonious EHR systems success model and the measurement scale can be used to benchmark EHR systems success across organizations and units and over time. PMID:29315323

  18. A Survey on Nickel Titanium Rotary Instruments and their Usage Techniques by Endodontists in India

    PubMed Central

    Saraf, Prahlad A; Penukonda, Raghavendra; Vanaki, Sneha S; Kamatagi, Laxmikant

    2017-01-01

    Introduction The preference and usage of nickel titanium rotary instruments varies from individual to individual based on their technique, experience with the rotary systems and the clinical situation. Very limited information is available to explain the adoption of changing concepts with respect to nickel titanium rotary instruments pertaining to the endodontists in India. Aim The aim of this study was to conduct a questionnaire survey to acquire the knowledge concerning different NiTi rotary instruments and their usage techniques by endodontists in India. Materials and Methods A Survey questionnaire was designed which consisted of 32 questions regarding designation, demographics, experience with rotary instruments, usage of different file systems, usage techniques, frequency of reuse, occurrence of file fracture, reasons and their management was distributed by hand in the national postgraduate convention and also disseminated via electronic medium to 400 and 600 endodontists respectively. Information was collected from each individual to gain insight into the experiences and beliefs of endodontists concerning the new endodontic technology of rotary NiTi instrumentation based on their clinical experience with the rotary systems. The questions were designed to ascertain the problems, patterns of use and to identify areas of perceived or potential concern regarding the rotary instruments and the data acquired was statistically evaluated using Fisher’s-exact test and the Chi-Square test. Results Overall 63.8% (638) endodontists responded. ProTaper was one of the most commonly used file system followed by M two and ProTaper Next. There was a significant co relation between the years of experience and the file re use frequency, preparation technique, file separation, management of file separation. Conclusion A large number of Endodontists prefer to reuse the rotary NiTi instruments. As there was an increase in the experience, the incidence of file separation reduced

  19. New hydrologic instrumentation in the U.S. Geological Survey

    USGS Publications Warehouse

    Latkovich, V.J.; Shope, W.G.; ,

    1991-01-01

    New water-level sensing and recording instrumentation is being used by the U.S. Geological Survey for monitoring water levels, stream velocities, and water-quality characteristics. Several of these instruments are briefly described. The Basic Data Recorder (BDR) is an electronic data logger, that interfaces to sensor systems through a serial-digital interface standard (SDI-12), which was proposed by the data-logger industry; the Incremental Shaft Encoder is an intelligent water-level sensor, which interfaces to the BDR through the SDI-12; the Pressure Sensor is an intelligent, nonsubmersible pressure sensor, which interfaces to the BDR through the SDI-12 and monitors water levels from 0 to 50 feet; the Ultrasonic Velocity Meter is an intelligent, water-velocity sensor, which interfaces to the BDR through the SDI-12 and measures the velocity across a stream up to 500 feet in width; the Collapsible Hand Sampler can be collapsed for insertion through holes in the ice and opened under the ice to collect a water sample; the Lighweight Ice Auger, weighing only 32 pounds, can auger 6- and 8-inch holes through approximately 3.5 feet of ice; and the Ice Chisel has a specially hardened steel blade and 6-foot long, hickory D-handle.

  20. A Follow-Up Study of "Teacher Beliefs Survey": A Psychometric Investigation of the Instrument and Its Educational Implications.

    ERIC Educational Resources Information Center

    Benjamin, Jane; Petersen, Naomi Jeffery; Sink, Chris; Walker, Brenda

    The construct validity of the revised Teacher Beliefs Survey (TBS) (S. Woolley and A. Woolley, 1999) was examined, and the populations that can use this instrument reliably were explored in this study. The TBS was designed to identify the dimensions of classroom practices. The revised instrument, which contained additional subscale items, was…

  1. Advanced Camera for Surveys Instrument Handbook for Cycle 25 v. 16.0

    NASA Astrophysics Data System (ADS)

    Avila, R. J.

    2017-01-01

    The Advanced Camera for Surveys (ACS), a third-generation instrument, was installed in the Hubble Space Telescope during Servicing Mission 3B, on March 7, 2002. Its primary purpose was to increase HST imaging discovery efficiency by about a factor of 10, with a combination of detector area and quantum efficiency that surpasses previous instruments. ACS has three independent cameras that have provided wide-field, high resolution, and ultraviolet imaging capabilities respectively, using a broad assortment of filters designed to address a large range of scientific goals. In addition, coronagraphic, polarimetric, and grism capabilities have made the ACS a versatile and powerful instrument. The ACS Instrument Handbook, which is maintained by the ACS Team at STScI, descr ibes the instrument properties, performance, operations, and calibration. It is the basic technical reference manual for the instrument, and should be used with other documents (listed in Table 1.1) for writing Phase I proposals, detailed Phase II programs, and for data analysis. (See Figure 1.1). In May 2009, Servicing Mission 4 (SM4) successfully restored the ACS Wide Field Camera (WFC) to regular service after its failure in January 2007. Unfortunately, the ACS High Resolution Camera (HRC) was not restored to operation during SM4, so it cannot be proposed for new observations. Nevertheless, this handbook retains description of the HRC to support analysis of archived observations. The ACS Solar Blind Channel (SBC) was unaffected by the January 2007 failure of WFC and HRC. The SBC has remained in steady operation, and was not serviced during SM4. It remains available for new observations.

  2. Mechanical Design of NESSI: New Mexico Tech Extrasolar Spectroscopic Survey Instrument

    NASA Technical Reports Server (NTRS)

    Santoro, Fernando G.; Olivares, Andres M.; Salcido, Christopher D.; Jimenez, Stephen R.; Jurgenson, Colby A.; Hrynevych, Michael A.; Creech-Eakman, Michelle J.; Boston, Penny J.; Schmidt, Luke M.; Bloemhard, Heather; hide

    2011-01-01

    NESSI: the New Mexico Tech Extrasolar Spectroscopic Survey Instrument is a ground-based multi-object spectrograph that operates in the near-infrared. It will be installed on one of the Nasmyth ports of the Magdalena Ridge Observatory (MRO) 2.4-meter Telescope sited in the Magdalena Mountains, about 48 km west of Socorro-NM. NESSI operates stationary to the telescope fork so as not to produce differential flexure between internal opto-mechanical components during or between observations. An appropriate mechanical design allows the instrument alignment to be highly repeatable and stable for both short and long observation timescales, within a wide-range of temperature variation. NESSI is optically composed of a field lens, a field de-rotator, re-imaging optics, an auto-guider and a Dewar spectrograph that operates at LN2 temperature. In this paper we report on NESSI's detailed mechanical and opto-mechanical design, and the planning for mechanical construction, assembly, integration and verification.

  3. Proving instruments credible in the early nineteenth century: The British Magnetic Survey and site-specific experimentation

    PubMed Central

    Goodman, Matthew

    2016-01-01

    For several decades now, many histories of science have sought to emphasize the important role of instruments and other material objects in the operation of science. Many, too, have been attentive to ideas of space and place and the different geographies which are visible in the historical practice of science. This paper draws on both traditions in its interpretation of a heretofore neglected aspect of Britain's nineteenth-century geomagnetic story: that of the British Magnetic Survey, 1833–38. Far from being a footnote to the more expansive geomagnetic projects then taking place in mainland Europe or to the later British worldwide magnetic scheme, this paper argues that the British Magnetic Survey represents an important instance in which magnetic instruments, their users and their makers, were tested, developed and ultimately proved credible.

  4. Student Destination Surveys: Design and Development of an Instrument for Use by TAFE Agencies.

    ERIC Educational Resources Information Center

    Walsh, Lynne

    The development of the student destination survey instrument was a response to an identified need for a tool to measure the effectiveness of Technical and Further Education (TAFE) programs in Australia. The requirement was for a tool that was flexible in accommodating changing course structures and consistent across state and territory boundaries.…

  5. Analysis on detection accuracy of binocular photoelectric instrument optical axis parallelism digital calibration instrument

    NASA Astrophysics Data System (ADS)

    Ying, Jia-ju; Yin, Jian-ling; Wu, Dong-sheng; Liu, Jie; Chen, Yu-dan

    2017-11-01

    Low-light level night vision device and thermal infrared imaging binocular photoelectric instrument are used widely. The maladjustment of binocular instrument ocular axises parallelism will cause the observer the symptom such as dizziness, nausea, when use for a long time. Binocular photoelectric equipment digital calibration instrument is developed for detecting ocular axises parallelism. And the quantitative value of optical axis deviation can be quantitatively measured. As a testing instrument, the precision must be much higher than the standard of test instrument. Analyzes the factors that influence the accuracy of detection. Factors exist in each testing process link which affect the precision of the detecting instrument. They can be divided into two categories, one category is factors which directly affect the position of reticle image, the other category is factors which affect the calculation the center of reticle image. And the Synthesize error is calculated out. And further distribute the errors reasonably to ensure the accuracy of calibration instruments.

  6. Development of a Computer-Based Survey Instrument for Organophosphate and N-Methyl-Carbamate Exposure Assessment among Agricultural Pesticide Handlers

    PubMed Central

    Hofmann, Jonathan N.; Checkoway, Harvey; Borges, Ofelio; Servin, Flor; Fenske, Richard A.; Keifer, Matthew C.

    2010-01-01

    Background: Assessment of occupational pesticide exposures based on self-reported information can be challenging, particularly with immigrant farm worker populations for whom specialized methods are needed to address language and cultural barriers and account for limited literacy. An audio computer-assisted self-interview (A-CASI) survey instrument was developed to collect information about organophosphate (OP) and N-methyl-carbamate (CB) exposures and other personal characteristics among male agricultural pesticide handlers for an ongoing cholinesterase biomonitoring study in Washington State. Objectives: To assess the feasibility of collecting data using the A-CASI instrument and evaluate reliability for a subset of survey items. Methods: The survey consisted of 64 items administered in Spanish or English on a touch-screen tablet computer. Participants listened to digitally recorded questions on headphones and selected responses on the screen, most of which were displayed as images or icons to facilitate participation of low literacy respondents. From 2006–2008, a total of 195 participants completed the survey during the OP/CB application seasons on at least one occasion. Percent agreement and kappa coefficients were calculated to evaluate test–retest reliability for selected characteristics among 45 participants who completed the survey on two separate occasions within the same year. Results: Almost all participants self-identified as Hispanic or Latino (98%), and 97% completed the survey in Spanish. Most participants completed the survey in a half-hour or less, with minimal assistance from on-site research staff. Analyses of test–retest reliability showed substantial agreement for most demographic, work history, and health characteristics and at least moderate agreement for most variables related to personal protective equipment use during pesticide applications. Conclusions: This A-CASI survey instrument is a novel method that has been used successfully

  7. Evaluation of two posture survey instruments for assessing computing postures among college students

    PubMed Central

    Menéndez, Cammie Chaumont; Amick, Benjamin C.; Chang, Che-Hsu (Joe); Harrist, Ronald B.; Jenkins, Mark; Robertson, Michelle; Janowitz, Ira; Rempel, David M.; Katz, Jeffrey N.; Dennerlein, Jack T.

    2012-01-01

    Objective To determine agreement between two posture assessment survey instruments and which, if any, were correlated with experiencing upper extremity musculoskeletal symptoms. Methods Thirty undergraduate participants had three postural assessment surveys completed, one each for three separate 7-day data collection periods during a semester. Two observation assessment tools were used, a modified Rapid Upper Limb Assessment (mRULA) for computer users for the right and left limbs and the University of California Computer Use Checklist. Concurrently, upper extremity musculoskeletal symptom experience paired to each postural assessment was measured. Lin’s concordance correlation coefficient evaluated survey agreement and multi-level statistical models described associations between survey responses and symptoms. Results There was no agreement between the two postural assessment tool scores (p > 0.85). In adjusted models, the UC Computer Use Checklist was positively associated with symptoms occurrence (OR = 1.4, 90% CI 1.2–1.6 for any symptoms; OR = 1.3, 90% CI 1.0–1.6 for moderate or greater symptoms). Associations with mRULA scores were inconsistent in that they were sometimes protective and sometimes indicators of risk, depending on the covariates included in the models. Conclusion The mRULA for computer users and the UC Computer Use Checklist were independent of each other; however, due to the inconsistent associations with symptoms we cannot conclude one instrument is superior to the other. Our data do suggest the UC Computer Use Checklist demonstrates a traditional relationship with symptoms, where increasing scores signifiy greater risk. We observed a nontraditional relatioship with symptoms for the mRULA for computer users that needs to be further examined. This is a pilot study and, thus, findings should be interpreted as exploratory. Associations observed in the current study will be used to test hypotheses in the cohort study recently conducted. PMID

  8. LBL's Pollution Instrumentation Comparability Program.

    ERIC Educational Resources Information Center

    McLaughlin, R. D.; And Others

    1979-01-01

    Contained are condensed excerpts from the Lawrence Berkeley Laboratory Survey of Instrumentation for Environmental Monitoring. The survey describes instrumentation used to analyze air and water quality, radiation emissions, and biomedical impacts. (BB)

  9. The Study of Programs of Instruction for Handicapped Children and Youth in Day and Residential Facilities. Volume IV. Survey Instruments and Materials for the Survey of Separate Facilities and the Survey of SEA Special Education Divisions.

    ERIC Educational Resources Information Center

    Stephens, Susan A.; Lakin, K. Charlie

    This document, the fourth of five volumes of a study of programs of instruction for handicapped children and youth in separate day and residential facilities throughout the United States, contains instruments and materials used in two surveys designed to gather data for the study: (1) a survey of separate facilities; and (2) a survey of State…

  10. Quantitative research.

    PubMed

    Watson, Roger

    2015-04-01

    This article describes the basic tenets of quantitative research. The concepts of dependent and independent variables are addressed and the concept of measurement and its associated issues, such as error, reliability and validity, are explored. Experiments and surveys – the principal research designs in quantitative research – are described and key features explained. The importance of the double-blind randomised controlled trial is emphasised, alongside the importance of longitudinal surveys, as opposed to cross-sectional surveys. Essential features of data storage are covered, with an emphasis on safe, anonymous storage. Finally, the article explores the analysis of quantitative data, considering what may be analysed and the main uses of statistics in analysis.

  11. Development of a quality instrument for assessing the spontaneous reports of ADR/ADE using Delphi method in China.

    PubMed

    Chen, Lixun; Jiang, Ling; Shen, Aizong; Wei, Wei

    2016-09-01

    The frequently low quality of submitted spontaneous reports is of an increasing concern; to our knowledge, no validated instrument exists for assessing case reports' quality comprehensively enough. This work was conducted to develop such a quality instrument for assessing the spontaneous reports of adverse drug reaction (ADR)/adverse drug event (ADE) in China. Initial evaluation indicators were generated using systematic and literature data analysis. Final indicators and their weights were identified using Delphi method. The final quality instrument was developed by adopting the synthetic scoring method. A consensus was reached after four rounds of Delphi survey. The developed quality instrument consisted of 6 first-rank indicators, 18 second-rank indicators, and 115 third-rank indicators, and each rank indicator has been weighted. It evaluates the quality of spontaneous reports of ADR/ADE comprehensively and quantitatively on six parameters: authenticity, duplication, regulatory, completeness, vigilance level, and reporting time frame. The developed instrument was tested with good reliability and validity, which can be used to comprehensively and quantitatively assess the submitted spontaneous reports of ADR/ADE in China.

  12. Development and Validation of a Cross-Cultural Knowledge, Attitudes, and Practices Survey Instrument for Chronic Kidney Disease in a Swahili-Speaking Population

    PubMed Central

    Stanifer, John W.; Karia, Francis; Voils, Corrine I.; Turner, Elizabeth L.; Maro, Venance; Shimbi, Dionis; Kilawe, Humphrey; Lazaro, Matayo; Patel, Uptal D.

    2015-01-01

    Introduction Non-communicable diseases are a growing global burden, and structured surveys can identify critical gaps to address this epidemic. In sub-Saharan Africa, there are very few well-tested survey instruments measuring population attributes related to non-communicable diseases. To meet this need, we have developed and validated the first instrument evaluating knowledge, attitudes and practices pertaining to chronic kidney disease in a Swahili-speaking population. Methods and Results Between December 2013 and June 2014, we conducted a four-stage, mixed-methods study among adults from the general population of northern Tanzania. In stage 1, the survey instrument was constructed in English by a group of cross-cultural experts from multiple disciplines and through content analysis of focus group discussions to ensure local significance. Following translation, in stage 2, we piloted the survey through cognitive and structured interviews, and in stage 3, in order to obtain initial evidence of reliability and construct validity, we recruited and then administered the instrument to a random sample of 606 adults. In stage 4, we conducted analyses to establish test-retest reliability and known-groups validity which was informed by thematic analysis of the qualitative data in stages 1 and 2. The final version consisted of 25 items divided into three conceptual domains: knowledge, attitudes and practices. Each item demonstrated excellent test-retest reliability with established content and construct validity. Conclusions We have developed a reliable and valid cross-cultural survey instrument designed to measure knowledge, attitudes and practices of chronic kidney disease in a Swahili-speaking population of Northern Tanzania. This instrument may be valuable for addressing gaps in non-communicable diseases care by understanding preferences regarding healthcare, formulating educational initiatives, and directing development of chronic disease management programs that

  13. Reliability and Validity of Survey Instruments to Measure Work-Related Fatigue in the Emergency Medical Services Setting: A Systematic Review.

    PubMed

    Patterson, P Daniel; Weaver, Matthew D; Fabio, Anthony; Teasley, Ellen M; Renn, Megan L; Curtis, Brett R; Matthews, Margaret E; Kroemer, Andrew J; Xun, Xiaoshuang; Bizhanova, Zhadyra; Weiss, Patricia M; Sequeira, Denisse J; Coppler, Patrick J; Lang, Eddy S; Higgins, J Stephen

    2018-02-15

    This study sought to systematically search the literature to identify reliable and valid survey instruments for fatigue measurement in the Emergency Medical Services (EMS) occupational setting. A systematic review study design was used and searched six databases, including one website. The research question guiding the search was developed a priori and registered with the PROSPERO database of systematic reviews: "Are there reliable and valid instruments for measuring fatigue among EMS personnel?" (2016:CRD42016040097). The primary outcome of interest was criterion-related validity. Important outcomes of interest included reliability (e.g., internal consistency), and indicators of sensitivity and specificity. Members of the research team independently screened records from the databases. Full-text articles were evaluated by adapting the Bolster and Rourke system for categorizing findings of systematic reviews, and the rated data abstracted from the body of literature as favorable, unfavorable, mixed/inconclusive, or no impact. The Grading of Recommendations, Assessment, Development and Evaluation (GRADE) methodology was used to evaluate the quality of evidence. The search strategy yielded 1,257 unique records. Thirty-four unique experimental and non-experimental studies were determined relevant following full-text review. Nineteen studies reported on the reliability and/or validity of ten different fatigue survey instruments. Eighteen different studies evaluated the reliability and/or validity of four different sleepiness survey instruments. None of the retained studies reported sensitivity or specificity. Evidence quality was rated as very low across all outcomes. In this systematic review, limited evidence of the reliability and validity of 14 different survey instruments to assess the fatigue and/or sleepiness status of EMS personnel and related shift worker groups was identified.

  14. Quantitative Analysis of Heavy Metals in Children's Toys and Jewelry: A Multi-Instrument, Multitechnique Exercise in Analytical Chemistry and Public Health

    ERIC Educational Resources Information Center

    Finch, Lauren E.; Hillyer, Margot M.; Leopold, Michael C.

    2015-01-01

    For most chemistry curricula, laboratory-based activities in quantitative and instrumental analysis continue to be an important aspect of student development/training, one that can be more effective if conceptual understanding is delivered through an inquiry-based process relating the material to relevant issues of public interest and student…

  15. Predicting Student Performance in Web-Based Distance Education Courses Based on Survey Instruments Measuring Personality Traits and Technical Skills

    ERIC Educational Resources Information Center

    Hall, Michael

    2008-01-01

    Two common web-based surveys, "Is Online Learning Right for Me?' and "What Technical Skills Do I Need?", were combined into a single survey instrument and given to 228 on-campus and 83 distance education students. The students were enrolled in four different classes (business, computer information services, criminal justice, and…

  16. Survey of quantitative antimicrobial consumption in two different pig finishing systems.

    PubMed

    Moreno, M A

    2012-09-29

    The primary objectives of this study were to: (a) collect on-farm antimicrobial use (AMU) data in fattener pigs employing two questionnaire-based surveys; (b) assess different quantitative measures for quantifying AMU in fattener pigs; (c) compare AMU in fattener pigs between two different management systems producing finishers: farrow-to-finish (FtF) farms versus finisher farms. Two questionnaires were designed both containing five groups of questions focused on the responder, the farm and AMU (eg, in-feed, in-drinking water and parenteral); both surveys were carried out by means of personal face-to-face interviews. Both surveys started with a sample size of 108 potentially eligible farms per survey; nevertheless, finally 67 finisher farms and 49 FtF farms were recruited. Overall percentages of animals exposed to antimicrobials (AM) were high (90 per cent in finisher farms and 54 per cent FtF farms); colistin (61 per cent and 33 per cent) and doxycycline (62 per cent and 23 per cent) were the most common AMs, followed by amoxicillin (51 per cent and 19 per cent) and lincomycin (49 per cent), respectively. Questionnaire-based surveys using face-to-face interviews are useful for capturing information regarding AMU at the farm level. Farm-level data per administration route can be used for comparative AMU analysis between farms. Nevertheless, for the analysis of the putative relationships between AMU and AM resistance, measures based on exposed animals or exposure events are needed.

  17. Use of a capillary electrophoresis instrument with laser-induced fluorescence detection for DNA quantitation. Comparison of YO-PRO-1 and PicoGreen assays.

    PubMed

    Guillo, Christelle; Ferrance, Jerome P; Landers, James P

    2006-04-28

    Highly selective and sensitive assays are required for detection and quantitation of the small masses of DNA typically encountered in clinical and forensic settings. High detection sensitivity is achieved using fluorescent labeling dyes and detection techniques such as spectrofluorometers, microplate readers and cytometers. This work describes the use of a laser-induced fluorescence (LIF) detector in conjunction with a commercial capillary electrophoresis instrument for DNA quantitation. PicoGreen and YO-PRO-1, two fluorescent DNA labeling dyes, were used to assess the potential of the system for routine DNA analysis. Linearity, reproducibility, sensitivity, limits of detection and quantitation, and sample stability were examined for the two assays. The LIF detector response was found to be linear (R2 > 0.999) and reproducible (RSD < 9%) in both cases. The PicoGreen assay displayed lower limits of detection and quantitation (20 pg and 60 pg, respectively) than the YO-PRO-1 assay (60 pg and 260 pg, respectively). Although a small variation in fluorescence was observed for the DNA/dye complexes over time, quantitation was not significantly affected and the solutions were found to be relatively stable for 80 min. The advantages of the technique include a 4- to 40-fold reduction in the volume of sample required compared to traditional assays, a 2- to 20-fold reduction in the volume of reagents consumed, fast and automated analysis, and low cost (no specific instrumentation required).

  18. [A survey instrument for evaluating psychological variables and risky sexual behavior among young adults at two university centers in Mexico].

    PubMed

    Piña López, Julio A; Robles Montijo, Susana; Rivera Icedo, Blanca M

    2007-11-01

    To measure the psychometric attributes of a survey instrument designed to evaluate historical and context variables that lead to high-risk sexual behaviors among a sample of university students in Mexico. Cross-sectional study of a sample of 1 346 university students in Mexico: 784 from the Sonora State Center for Higher Education in Hermosillo, Sonora, or 33.2% of its total enrollment; and 562 from the National Autonomous University of Mexico, at Tlalnepantla campus in Mexico State, or 23.5% of its total enrollment. The study took place in Hermosillo during the month of October 2006 and in Tlalnepantla from January to March 2006. The survey had 11 questions on sociodemographics, 7 on risky sexual behaviors, 22 on related motives, 8 on social context, and 6 on physical status prior to sexual relations. The survey was evaluated in terms of how well the questions were understood, its conceptual validity, and reliability. The final version of the survey instrument was composed of 44 questions. The reliability analysis produced an overall Cronbach alpha value of 0.821, taking into account all the variables combined and grouped by factor. Three factors were found that together accounted for 38.36% of the total variance: reasons for not using a condom in the first sexual relationship or throughout life, reasons for inconsistent use of a condom with a casual sex partner, and willingness to become sexually active and to engage in casual sex. The psychometric attributes of this survey instrument were found to be satisfactory. Those interested in using this instrument should become familiar with the theoretical model on which it is based, since understanding the results depends on properly defining the historical and context variables, and their interaction.

  19. Lack of quantitative training among early-career ecologists: a survey of the problem and potential solutions

    PubMed Central

    Ezard, Thomas H.G.; Jørgensen, Peter S.; Zimmerman, Naupaka; Chamberlain, Scott; Salguero-Gómez, Roberto; Curran, Timothy J.; Poisot, Timothée

    2014-01-01

    Proficiency in mathematics and statistics is essential to modern ecological science, yet few studies have assessed the level of quantitative training received by ecologists. To do so, we conducted an online survey. The 937 respondents were mostly early-career scientists who studied biology as undergraduates. We found a clear self-perceived lack of quantitative training: 75% were not satisfied with their understanding of mathematical models; 75% felt that the level of mathematics was “too low” in their ecology classes; 90% wanted more mathematics classes for ecologists; and 95% more statistics classes. Respondents thought that 30% of classes in ecology-related degrees should be focused on quantitative disciplines, which is likely higher than for most existing programs. The main suggestion to improve quantitative training was to relate theoretical and statistical modeling to applied ecological problems. Improving quantitative training will require dedicated, quantitative classes for ecology-related degrees that contain good mathematical and statistical practice. PMID:24688862

  20. Assessing the Learning Environment for Medical Students: An Evaluation of a Novel Survey Instrument in Four Medical Schools.

    PubMed

    Pololi, Linda H; Evans, Arthur T; Nickell, Leslie; Reboli, Annette C; Coplit, Lisa D; Stuber, Margaret L; Vasiliou, Vasilia; Civian, Janet T; Brennan, Robert T

    2017-06-01

    A practical, reliable, and valid instrument is needed to measure the impact of the learning environment on medical students' well-being and educational experience and to meet medical school accreditation requirements. From 2012 to 2015, medical students were surveyed at the end of their first, second, and third year of studies at four medical schools. The survey assessed students' perceptions of the following nine dimensions of the school culture: vitality, self-efficacy, institutional support, relationships/inclusion, values alignment, ethical/moral distress, work-life integration, gender equity, and ethnic minority equity. The internal reliability of each of the nine dimensions was measured. Construct validity was evaluated by assessing relationships predicted by our conceptual model and prior research. Assessment was made of whether the measurements were sensitive to differences over time and across institutions. Six hundred and eighty-six students completed the survey (49 % women; 9 % underrepresented minorities), with a response rate of 89 % (range over the student cohorts 72-100 %). Internal consistency of each dimension was high (Cronbach's α 0.71-0.86). The instrument was able to detect significant differences in the learning environment across institutions and over time. Construct validity was supported by demonstrating several relationships predicted by our conceptual model. The C-Change Medical Student Survey is a practical, reliable, and valid instrument for assessing the learning environment of medical students. Because it is sensitive to changes over time and differences across institution, results could potentially be used to facilitate and monitor improvements in the learning environment of medical students.

  1. A SURVEY INSTRUMENT FOR IDENTIFYING CLUSTERS OF KNOWLEDGE AND COMPETENCIES ASSOCIATED WITH PERFORMANCE OF FOOD SERVICE WORK, REPORT NUMBER 9.

    ERIC Educational Resources Information Center

    RAHMLOW, HAROLD F.; AND OTHERS

    AS AN INITIAL STEP TOWARD IMPROVING VOCATIONAL CURRICULUMS IN FOOD SERVICING, A SPECIAL RESEARCH TEAM DEVELOPED AND FIELD TESTED A SURVEY INSTRUMENT FOR OBTAINING UP-TO-DATE INFORMATION ABOUT MAJOR TYPES AND COMBINATIONS OF TASKS PERFORMED BY FOOD SERVICE WORKERS. THE INSTRUMENT COVERED THE FOLLOWING BASIC TASKS OF FOOD SERVICING--(1) FOOD…

  2. A Program to Improve Social Studies Instruction in the Ottumwa Community Schools. Surveys, Grades 3-12, Measurement Instruments, Project #1009.

    ERIC Educational Resources Information Center

    Ahrens, Willis

    As part of a social studies instruction improvement program, measurement instruments were developed to measure attitudes of and evaluate courses for teachers and students in grades 3-12. The measurement instruments presented are surveys used in the social studies program. The purposes of the improvement project are to use the multimedia approach…

  3. Quantitative Survey of Laypersons' Attitudes Toward Organ Transplantation in Japan.

    PubMed

    Okita, T; Hsu, E; Aizawa, K; Nakada, H; Toya, W; Matsui, K

    In comparison with foreign countries, living-organ transplantations (LOT) have been performed more frequently than dead organ transplants, including brain-dead organ transplantation (BOT) in Japan. This situation has given rise to organ transplantation tourism. Therefore, we clarify laypersons' preferences regarding organ transplantation that are producing the current situation in Japan, to suggest a possible framework for further efforts. Voluntary completion of a quantitative and anonymous survey was promoted online (a sample size of 1030). The questionnaire had two types of variables concerning demographic characteristics and organ transplantation-related issues. LOT was favored over BOT. However, for willingness to donate to family members, the participants showed a significantly more positive attitude toward brain-dead organ donors (BODs) than living organ donors (LODs). In the evaluation of each transplantation technology, BOT and LOT were positioned in the middle, between transplantation that does not depend on others and the utilization of animal organs. Although LOT was favored over BOT, for participants hypothesized to be in a position to donate and receive organs, BODs received a conversely better reputation than LODs. Our survey and discussion suggest that the present conditions of organ transplantation in Japan might be because there is a lack of deliberation on transplantation tourism and LOT. Therefore, more surveys concerning LOT cases and the implications of avoidance of organs from brain-dead bodies, coupled with more discussions based on these surveys, are necessary to formulate a Japanese transplantation policy for the future. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Quantitative estimation of minimum offset for multichannel surface-wave survey with actively exciting source

    USGS Publications Warehouse

    Xu, Y.; Xia, J.; Miller, R.D.

    2006-01-01

    Multichannel analysis of surface waves is a developing method widely used in shallow subsurface investigations. The field procedures and related parameters are very important for successful applications. Among these parameters, the source-receiver offset range is seldom discussed in theory and normally determined by empirical or semi-quantitative methods in current practice. This paper discusses the problem from a theoretical perspective. A formula for quantitatively evaluating a layered homogenous elastic model was developed. The analytical results based on simple models and experimental data demonstrate that the formula is correct for surface wave surveys for near-surface applications. ?? 2005 Elsevier B.V. All rights reserved.

  5. Use of Electrical and Electronic Instruments

    ERIC Educational Resources Information Center

    Mosbacher, C. J.; Thomas, E. J.

    1977-01-01

    Presents results of a trend survey of the present and planned use of electrical and electronic instruments. Microprocessors were found to have the highest predicted growth rate of all instruments included in the survey. (SL)

  6. Student Interest in Technology and Science (SITS) Survey: Development, Validation, and Use of a New Instrument

    ERIC Educational Resources Information Center

    Romine, William; Sadler, Troy D.; Presley, Morgan; Klosterman, Michelle L.

    2014-01-01

    This study presents the systematic development, validation, and use of a new instrument for measuring student interest in science and technology. The Student Interest in Technology and Science (SITS) survey is composed of 5 sub-sections assessing the following dimensions: interest in learning science, using technology to learn science, science…

  7. An automated gas chromatography time-of-flight mass spectrometry instrument for the quantitative analysis of halocarbons in air

    NASA Astrophysics Data System (ADS)

    Obersteiner, F.; Bönisch, H.; Engel, A.

    2016-01-01

    We present the characterization and application of a new gas chromatography time-of-flight mass spectrometry instrument (GC-TOFMS) for the quantitative analysis of halocarbons in air samples. The setup comprises three fundamental enhancements compared to our earlier work (Hoker et al., 2015): (1) full automation, (2) a mass resolving power R = m/Δm of the TOFMS (Tofwerk AG, Switzerland) increased up to 4000 and (3) a fully accessible data format of the mass spectrometric data. Automation in combination with the accessible data allowed an in-depth characterization of the instrument. Mass accuracy was found to be approximately 5 ppm in mean after automatic recalibration of the mass axis in each measurement. A TOFMS configuration giving R = 3500 was chosen to provide an R-to-sensitivity ratio suitable for our purpose. Calculated detection limits are as low as a few femtograms by means of the accurate mass information. The precision for substance quantification was 0.15 % at the best for an individual measurement and in general mainly determined by the signal-to-noise ratio of the chromatographic peak. Detector non-linearity was found to be insignificant up to a mixing ratio of roughly 150 ppt at 0.5 L sampled volume. At higher concentrations, non-linearities of a few percent were observed (precision level: 0.2 %) but could be attributed to a potential source within the detection system. A straightforward correction for those non-linearities was applied in data processing, again by exploiting the accurate mass information. Based on the overall characterization results, the GC-TOFMS instrument was found to be very well suited for the task of quantitative halocarbon trace gas observation and a big step forward compared to scanning, quadrupole MS with low mass resolving power and a TOFMS technique reported to be non-linear and restricted by a small dynamical range.

  8. Item-level psychometrics of the ADL instrument of the Korean National Survey on persons with physical disabilities.

    PubMed

    Hong, Ickpyo; Lee, Mi Jung; Kim, Moon Young; Park, Hae Yean

    2017-10-01

    The aim of this study is to investigate the psychometrics of the 12 items of an instrument assessing activities of daily living (ADL) using an item response theory model. A total of 648 adults with physical disabilities and having difficulties in ADLs were retrieved from the 2014 Korean National Survey on People with Disabilities. The psychometric testing included factor analysis, internal consistency, precision, and differential item functioning (DIF) across categories including sex, older age, marital status, and physical impairment area. The sample had a mean age of 69.7 years old (SD = 13.7). The majority of the sample had lower extremity impairments (62.0%) and had at least 2.1 chronic conditions. The instrument demonstrated unidimensional construct and good internal consistency (Cronbach's alpha = 0.95). The instrument precisely estimated person measures within a wide range of theta values (-2.22 logits < θ < 0.27 logits) with a reliability of 0.9. Only the changing position item demonstrated misfit (χ 2  = 36.6, df = 17, p = 0.0038), and the dressing item demonstrated DIF on the impairment type (upper extremity/others, McFadden's Pseudo R 2  > 5.0%). Our findings indicate that the dressing item would need to be modified to improve its psychometrics. Overall, the ADL instrument demonstrates good psychometrics, and thus, it may be used as a standardized instrument for measuring disability in rehabilitation contexts. However, the findings are limited to adults with physical disabilities. Future studies should replicate psychometric testing for survey respondents with other disorders and for children.

  9. Results of qualification tests on water-level sensing instruments, 1987

    USGS Publications Warehouse

    Olive, T.E.

    1989-01-01

    The U.S. Geological Survey 's Hydrologic Instrumentation Facility at the Stennis Space Center, Mississippi, conducts qualification tests on water level sensing instruments. Instrument systems, which meet or exceed the Survey 's minimum performance requirements, are placed on the Survey 's Qualified Products List. The qualification tests conducted in 1987 added two instrument systems to the Survey 's Qualified Products List. One system met requirements for use at a daily-discharge station , and the other system met requirements for a special-case station. The report is prepared for users of hydrologic instruments. The report provides a list of instrument features, describes the instrument systems, summarizes test procedures, and presents test results for the two instrument systems that met the Survey 's minimum performance standards for the 1987 round of qualification tests. (USGS)

  10. Marine oil pollution and beached bird surveys: the development of a sensitive monitoring instrument.

    PubMed

    Camphuysen, C J; Heubeck, M

    2001-01-01

    One of the most obvious adverse effects of (chronic) pollution of the world's oceans and seas with mineral oil is the mortality of seabirds. Systematic surveys of beachcast corpses of birds ('beached bird surveys') have been used in many parts of the world to document the effect of oil pollution, but particularly so in Western Europe and in parts of North America. In this paper, the history, current schemes, methods and possible (future) use of beached bird surveys are described and discussed, because the value of beached bird surveys has been hotly disputed. Oil pollution is known since the late 19th century, while the first beached bird surveys were conducted in the 1920s. Due to the amount of man-power needed for these surveys, most beached bird survey programs thrived only through the work of a large number of volunteers. However, most programs have resulted in substantial amounts of high quality data, often covering many consecutive years. One of the main shortcomings of many beached bird survey programs was the emphasis on stranded bird numbers rather than on relative measures, such as oil rates (percentage of corpses oiled of all corpses found). Sources of pollution, particularly so in chronically polluted regions such as the North Sea, the Baltic, the Mediterranean and the waters around Newfoundland, are insufficiently known, but could be studied through a sampling program connected to beached bird surveys. Suggestions for standardization of methods are presented, which could lead to a global and highly sensitive monitoring instrument of marine oil pollution.

  11. Measuring stigma among abortion providers: assessing the Abortion Provider Stigma Survey instrument.

    PubMed

    Martin, Lisa A; Debbink, Michelle; Hassinger, Jane; Youatt, Emily; Eagen-Torkko, Meghan; Harris, Lisa H

    2014-01-01

    We explored the psychometric properties of 15 survey questions that assessed abortion providers' perceptions of stigma and its impact on providers' professional and personal lives referred to as the Abortion Provider Stigma Survey (APSS). We administered the survey to a sample of abortion providers recruited for the Providers' Share Workshop (N = 55). We then completed analyses using Stata SE/12.0. Exploratory factor analysis, which resulted in 13 retained items and identified three subscales: disclosure management, resistance and resilience, and discrimination. Stigma was salient in abortion provider's lives: they identified difficulties surrounding disclosure (66%) and felt unappreciated by society (89%). Simultaneously, workers felt they made a positive contribution to society (92%) and took pride in their work (98%). Paired t-test analyses of the pre- and post-Workshop APSS scores showed no changes in the total score. However, the Disclosure Management subscale scores were significantly lower (indicating decreased stigma) for two subgroups of participants: those over the age of 30 and those with children. This analysis is a promising first step in the development of a quantitative tool for capturing abortion providers' experiences of and responses to pervasive abortion stigma.

  12. Upward Transfer in STEM Fields of Study: A New Conceptual Framework and Survey Instrument for Institutional Research

    ERIC Educational Resources Information Center

    Wang, Xueli

    2016-01-01

    This chapter describes a new conceptual framework that informs research on factors influencing transfer in STEM fields of study from 2-year to 4-year institutions, presents a new survey instrument based on the framework, and offers directions for future research in this area.

  13. Identity and Philanthropy: Designing a Survey Instrument to Operationalize Lesbian, Gay, Bisexual, Transgender, and Queer Alumni Giving

    ERIC Educational Resources Information Center

    Garvey, Jason C.

    2013-01-01

    This study investigated philanthropic giving to higher education among lesbian, gay, bisexual, transgender, and queer (LGBTQ) alumni. The primary purpose was to create a multi-institutional survey instrument that operationalizes philanthropic involvement and motivation among LGBTQ alumni. Additional objectives included creating factors and items…

  14. Questionnaire survey on the use of rotary nickel-titanium endodontic instruments by Australian dentists.

    PubMed

    Parashos, P; Messer, H H

    2004-04-01

    To ascertain the extent of the adoption and use of rotary nickel-titanium (NiTi) instruments and techniques in general dental practice and specialist endodontic practice in Australia in 2001. A questionnaire survey comprising 43 questions was developed by first creating questions, then pilot testing with 10 postgraduate students in endodontics, followed by a final revision. The final series of questions covered demographics, patterns of rotary NiTi usage, issues associated with NiTi usage and training in NiTi use. The sampling frame was 908, comprising 64 endodontists and 844 general dentists. The overall response rate was 87%. Rotary NiTi instruments were used by 22% of general dentists and 64% of endodontists. The two main reasons for not using rotary NiTi were 'no perceived advantage' and 'too fragile'. Instrument fracture had been experienced by 74% of respondents, and 72% of these had fractured one to five files for the two main perceived reasons of 'excessive pressure on the file' and 'over-usage'. The next two most common problems encountered were 'binding' (53%) and 'ledging' (45%). Very high proportions of positive experiences were noted. Most respondents (73%) had attended one or more continuing education courses, most of which were provided by dental supply companies (64%). The results indicate a sensible and responsible approach to the incorporation of rotary NiTi instruments and techniques into root canal treatment. Dentists were aware of the limitations of the new technology, but were taking steps to become familiar with the properties and behaviour of the instruments. Instrument fracture was common, but it was of low frequency and did not deter dentists from using the technology.

  15. Survey Instruments to Assess Patient Experiences With Access and Coordination Across Health Care Settings: Available and Needed Measures.

    PubMed

    Quinn, Martha; Robinson, Claire; Forman, Jane; Krein, Sarah L; Rosland, Ann-Marie

    2017-07-01

    Improving access can increase the providers a patient sees, and cause coordination challenges. For initiatives that increase care across health care settings, measuring patient experiences with access and care coordination will be crucial. Map existing survey measures of patient experiences with access and care coordination expected to be relevant to patients accessing care across settings. Preliminarily examine whether aspects of access and care coordination important to patients are represented by existing measures. Structured literature review of domains and existing survey measures related to access and care coordination across settings. Survey measures, and preliminary themes from semistructured interviews of 10 patients offered VA-purchased Community Care, were mapped to identified domains. We identified 31 existing survey instruments with 279 items representing 6 access and 5 care coordination domains relevant to cross-system care. Domains frequently assessed by existing measures included follow-up coordination, primary care access, cross-setting coordination, and continuity. Preliminary issues identified in interviews, but not commonly assessed by existing measures included: (1) acceptability of distance to care site given patient's clinical situation; (2) burden on patients to access and coordinate care and billing; (3) provider familiarity with Veteran culture and VA processes. Existing survey instruments assess many aspects of patient experiences with access and care coordination in cross-system care. Systems assessing cross-system care should consider whether patient surveys accurately reflect the level of patients' concerns with burden to access and coordinate care, and adequately reflect the impact of clinical severity and cultural familiarity on patient preferences.

  16. Measuring determinants of career satisfaction of anesthesiologists: validation of a survey instrument.

    PubMed

    Afonso, Anoushka M; Diaz, James H; Scher, Corey S; Beyl, Robbie A; Nair, Singh R; Kaye, Alan David

    2013-06-01

    To measure the parameter of job satisfaction among anesthesiologists. Survey instrument. Academic anesthesiology departments in the United States. 320 anesthesiologists who attended the annual meeting of the ASA in 2009 (95% response rate). The anonymous 50-item survey collected information on 26 independent demographic variables and 24 dependent ranked variables of career satisfaction among practicing anesthesiologists. Mean survey scores were calculated for each demographic variable and tested for statistically significant differences by analysis of variance. Questions within each domain that were internally consistent with each other within domains were identified by Cronbach's alpha ≥ 0.7. P-values ≤ 0.05 were considered statistically significant. Cronbach's alpha analysis showed strong internal consistency for 10 dependent outcome questions in the practice factor-related domain (α = 0.72), 6 dependent outcome questions in the peer factor-related domain (α = 0.71), and 8 dependent outcome questions in the personal factor-related domain (α = 0.81). Although age was not a variable, full-time status, early satisfaction within the first 5 years of practice, working with respected peers, and personal choice factors were all significantly associated with anesthesiologist job satisfaction. Improvements in factors related to job satisfaction among anesthesiologists may lead to higher early and current career satisfaction. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. E-Books in Academic Libraries: Results of a Survey Carried out in Sweden and Lithuania

    ERIC Educational Resources Information Center

    Maceviciute, Elena; Wilson, T. D.; Gudinavicius, Arunas; Šuminas, Andrius

    2017-01-01

    Introduction: This paper reports on a study of e-books issues in academic libraries in two European countries representative of small language markets--Sweden and Lithuania. Method: Questionnaire surveys, using the same instrument, were carried out in Swedish and Lithuanian academic libraries. Analysis: Quantitative analysis was performed using…

  18. Survey of Native English Speakers and Spanish-Speaking English Language Learners in Tertiary Introductory Statistics

    ERIC Educational Resources Information Center

    Lesser, Lawrence M.; Wagler, Amy E.; Esquinca, Alberto; Valenzuela, M. Guadalupe

    2013-01-01

    The framework of linguistic register and case study research on Spanish-speaking English language learners (ELLs) learning statistics informed the construction of a quantitative instrument, the Communication, Language, And Statistics Survey (CLASS). CLASS aims to assess whether ELLs and non-ELLs approach the learning of statistics differently with…

  19. The Community College Survey of Men: An Initial Validation of the Instrument's Non-Cognitive Outcomes Construct

    ERIC Educational Resources Information Center

    Wood, J. \\Luke; Harris, Frank, III.

    2013-01-01

    The purpose of this manuscript is to discuss the utility of the Community College Survey of Men (CCSM[c]), an instrument designed to examine predictors of student success for men in community colleges. The authors highlight initial validation results from a recent pilot of the CCSM[c], with a focus on the non-cognitive outcomes construct employed…

  20. The development of NEdSERV: quantitative instrumentation to measure service quality in nurse education.

    PubMed

    Roberts, P

    1999-07-01

    The political climate of health care provision and education for health care in the latter years of the 20th century is evolving from the uncertainty of newly created markets to a more clearly focused culture of collaboration, dissemination of good practice, with an increased emphasis on quality provision and its measurement. The need for provider units to prove and improve efficiency and effectiveness through evidence-based quality strategies in order to stay firmly in the market place has never been more necessary. The measurement of customer expectations and perceptions of delivered service quality is widely utilized as a basis for customer retention and business growth in both commercial and non-profit organizations. This paper describes the methodological development of NEdSERV--quantitative instrumentation designed to measure and respond to ongoing stakeholder expectations and perceptions of delivered service quality within nurse education.

  1. A survey of international legal instruments to examine their effectiveness in improving global health and in realizing health rights.

    PubMed

    Wilson, Arthur; Daar, Abdallah S

    2013-01-01

    Many global health issues, almost by definition, do not recognize state borders and therefore require bi-lateral, or more often multi-lateral international solutions. These latter solutions are articulated in international instruments (declarations, conventions, treaties, constitutions of international bodies, etc). However, the gap between formal adoption of such instruments by signatory states and substantive implementation of the articulated solutions can be very wide. This paper surveys a selection of international legal instruments, including those where the sought after positive outcomes have been achieved, and those that have been ineffective, with little or no real progress being made. The paper looks for commonalities, both in the nature of the problems and the forms of the international legal instruments, to seek answers as to why some instruments ultimately succeeded where others failed. It also provides some guidance to law/ treaty makers to help ensure that they frame future instruments in such a way as to maximize the probability that those instruments will have a substantive positive impact on global health and health rights. © 2013 American Society of Law, Medicine & Ethics, Inc.

  2. Development of an instrument designed to measure employees' perceptions of workplace breastfeeding support.

    PubMed

    Greene, Sally W; Olson, Beth H

    2008-09-01

    Breastfeeding rates remain low in the United States, especially among working women. Unfortunately, no quantitative instrument exists to facilitate the examination of why women who return to work discontinue breastfeeding sooner than the general population. The objective of this study was to develop an instrument to measure female employees' perceptions of breastfeeding support in the workplace, which would be suitable for piloting with the target population. Examination of the literature, reviews with experts, and one-on-one interviews with women who had experience combining breastfeeding and work were used to create the instrument subscales and items. Examination of the literature was used to develop four subscales: company policies/work culture, manager support, co-worker support, and workflow. Expert review resulted in the addition of a fifth subscale, the physical environment of the breastfeeding space. One-on-one interviews were used to ensure that the item wording was appropriate for the target population. Eighteen items were added, and 15 were reworded based on comments from the expert review and from the interviews. The resulting survey contained 54 items that required either categorical yes/no or Likert scale responses. Results from this process indicate the survey subscales and items adequately reflect women's perceptions of breastfeeding support in the workplace and the instrument is appropriate for piloting with new mother employees.

  3. Organizational Member Involvement in Physical Activity Coalitions across the United States: Development and Testing of a Novel Survey Instrument for Assessing Coalition Functioning

    ERIC Educational Resources Information Center

    Bornstein, Daniel B.; Pate, Russell R.; Beets, Michael W.; Saunders, Ruth P.; Blair, Steven N.

    2015-01-01

    Introduction: Coalitions are often composed of member organizations. Member involvement is thought to be associated with coalition success. No instrument currently exists for evaluating organizational member involvement in physical activity coalitions. This study aimed to develop a survey instrument for evaluating organizational member involvement…

  4. Evaluation of a large-scale quantitative respirator-fit testing program for healthcare workers: survey results.

    PubMed

    Wilkinson, Irene J; Pisaniello, Dino; Ahmad, Junaid; Edwards, Suzanne

    2010-09-01

    To present the evaluation of a large-scale quantitative respirator-fit testing program. Concurrent questionnaire survey of fit testers and test subjects. Ambulatory care, home nursing care, and acute care hospitals across South Australia. Quantitative facial-fit testing was performed with TSI PortaCount instruments for healthcare workers (HCWs) who wore 5 different models of a disposable P2 (N95-equivalent) respirator. The questionnaire included questions about the HCW's age, sex, race, occupational category, main area of work, smoking status, facial characteristics, prior training and experience in use of respiratory masks, and number of attempts to obtain a respirator fit. A total of 6,160 HCWs were successfully fitted during the period from January through July 2007. Of the 4,472 HCWs who responded to the questionnaire and were successfully fitted, 3,707 (82.9%) were successfully fitted with the first tested respirator, 551 (12.3%) required testing with a second model, and 214 (4.8%) required 3 or more tests. We noted an increased pass rate on the first attempt over time. Asians (excluding those from South and Central Asia) had the highest failure rate (16.3% [45 of 276 Asian HCWs were unsuccessfully fitted]), and whites had the lowest (9.8% [426 of 4,338 white HCWs]). Race was highly correlated with facial shape. Among occupational groups, doctors had the highest failure rate (13.4% [81 of 604 doctors]), but they also had the highest proportion of Asians. Prior education and/or training in respirator use were not associated with a higher pass rate. Certain facial characteristics were associated with higher or lower pass rates with regard to fit testing, and fit testers were able to select a suitable respirator on the basis of a visual assessment in the majority of cases. For the fit tester, training and experience were important factors; however, for the HCW being fitted, prior experience in respirator use was not an important factor.

  5. Measuring children's self-reported sport participation, risk perception and injury history: development and validation of a survey instrument.

    PubMed

    Siesmaa, Emma J; Blitvich, Jennifer D; White, Peta E; Finch, Caroline F

    2011-01-01

    Despite the health benefits associated with children's sport participation, the occurrence of injury in this context is common. The extent to which sport injuries impact children's ongoing involvement in sport is largely unknown. Surveys have been shown to be useful for collecting children's injury and sport participation data; however, there are currently no published instruments which investigate the impact of injury on children's sport participation. This study describes the processes undertaken to assess the validity of two survey instruments for collecting self-reported information about child cricket and netball related participation, injury history and injury risk perceptions, as well as the reliability of the cricket-specific version. Face and content validity were assessed through expert feedback from primary and secondary level teachers and from representatives of peak sporting bodies for cricket and netball. Test-retest reliability was measured using a sample of 59 child cricketers who completed the survey on two occasions, 3-4 weeks apart. Based on expert feedback relating to face and content validity, modification and/or deletion of some survey items was undertaken. Survey items with low test-retest reliability (κ≤0.40) were modified or deleted, items with moderate reliability (κ=0.41-0.60) were modified slightly and items with higher reliability (κ≥0.61) were retained, with some undergoing minor modifications. This is the first survey of its kind which has been successfully administered to cricketers aged 10-16 years to collect information about injury risk perceptions and intentions for continued sport participation. Implications for its generalisation to other child sport participants are discussed. Copyright © 2010 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  6. The Mathematics Attitudes and Perceptions Survey: an instrument to assess expert-like views and dispositions among undergraduate mathematics students

    NASA Astrophysics Data System (ADS)

    Code, Warren; Merchant, Sandra; Maciejewski, Wes; Thomas, Matthew; Lo, Joseph

    2016-08-01

    One goal of an undergraduate education in mathematics is to help students develop a productive disposition towards mathematics. A way of conceiving of this is as helping mathematical novices transition to more expert-like perceptions of mathematics. This conceptualization creates a need for a way to characterize students' perceptions of mathematics in authentic educational settings. This article presents a survey, the Mathematics Attitudes and Perceptions Survey (MAPS), designed to address this need. We present the development of the MAPS instrument and its validation on a large (N = 3411) set of student data. Results from various MAPS implementations corroborate results from analogous instruments in other STEM disciplines. We present these results and highlight some in particular: MAPS scores correlate with course grades; students tend to move away from expert-like orientations over a semester or year of taking a mathematics course; and interactive-engagement type lectures have less of a negative impact, but no positive impact, on students' overall orientations than traditional lecturing. We include the MAPS instrument in this article and suggest ways in which it may deepen our understanding of undergraduate mathematics education.

  7. Quantitative Radiology Reporting in Oncology: Survey of Oncologists and Radiologists

    PubMed Central

    Folio, Les R.; Nelson, Chelsye J.; Benjamin, Menashe; Ran, Ayelet; Engelhard, Guy; Bluemke, David A.

    2017-01-01

    OBJECTIVE Tumor quantification is essential for determining the clinical efficacy and response to established and evolving therapeutic agents in cancer trials. The purpose of this study was to seek the opinions of oncologists and radiologists about quantitative interactive and multimedia reporting. SUBJECTS AND METHODS Questionnaires were distributed to 253 oncologists and registrars and to 35 radiologists at our institution through an online survey application. Questions were asked about current reporting methods, methods for Response Evaluation Criteria in Solid Tumors (RECIST) tumor measurement, and preferred reporting format. RESULTS The overall response rates were 43.1% (109/253) for oncologists and 80.0% (28/35) for radiologists. The oncologists treated more than 40 tumor types. Most of the oncologists (65.7% [67/102]) and many radiologists (44.4% [12/27]) (p = 0.020) deemed the current traditional qualitative radiology reports insufficient for reporting tumor burden and communicating measurements. Most of the radiologists (77.8% [21/27]) and oncologists (85.5% [71/83]) (p = 0.95) agreed that key images with measurement annotations helped in finding previously measured tumors; however, only 43% of radiologists regularly saved key images. Both oncologists (64.2% [70/109]) and radiologists (67.9% [19/28]) (p = 0.83) preferred the ability to hyperlink measurements from reports to images of lesions as opposed to text-only reports. Approximately 60% of oncologists indicated that they handwrote tumor measurements on RECIST forms, and 40% used various digital formats. Most of the oncologists (93%) indicated that managing tumor measurements within a PACS would be superior to handwritten data entry and retyping of data into a cancer database. CONCLUSION Oncologists and radiologists agree that quantitative interactive reporting would be superior to traditional text-only qualitative reporting for assessing tumor burden in cancer trials. A PACS reporting system that

  8. Quantitative Radiology Reporting in Oncology: Survey of Oncologists and Radiologists.

    PubMed

    Folio, Les R; Nelson, Chelsye J; Benjamin, Menashe; Ran, Ayelet; Engelhard, Guy; Bluemke, David A

    2015-09-01

    Tumor quantification is essential for determining the clinical efficacy and response to established and evolving therapeutic agents in cancer trials. The purpose of this study was to seek the opinions of oncologists and radiologists about quantitative interactive and multimedia reporting. Questionnaires were distributed to 253 oncologists and registrars and to 35 radiologists at our institution through an online survey application. Questions were asked about current reporting methods, methods for Response Evaluation Criteria in Solid Tumors (RECIST) tumor measurement, and preferred reporting format. The overall response rates were 43.1% (109/253) for oncologists and 80.0% (28/35) for radiologists. The oncologists treated more than 40 tumor types. Most of the oncologists (65.7% [67/102]) and many radiologists (44.4% [12/27]) (p = 0.020) deemed the current traditional qualitative radiology reports insufficient for reporting tumor burden and communicating measurements. Most of the radiologists (77.8% [21/27]) and oncologists (85.5% [71/83]) (p = 0.95) agreed that key images with measurement annotations helped in finding previously measured tumors; however, only 43% of radiologists regularly saved key images. Both oncologists (64.2% [70/109]) and radiologists (67.9% [19/28]) (p = 0.83) preferred the ability to hyperlink measurements from reports to images of lesions as opposed to text-only reports. Approximately 60% of oncologists indicated that they handwrote tumor measurements on RECIST forms, and 40% used various digital formats. Most of the oncologists (93%) indicated that managing tumor measurements within a PACS would be superior to handwritten data entry and retyping of data into a cancer database. Oncologists and radiologists agree that quantitative interactive reporting would be superior to traditional text-only qualitative reporting for assessing tumor burden in cancer trials. A PACS reporting system that enhances and promotes collaboration between

  9. High School and Beyond. 1980 Senior Coort. Third-Follow-Up (1986). Data File User's Manual. Volume II: Survey Instruments. Contractor Report.

    ERIC Educational Resources Information Center

    Sebring, Penny; And Others

    Survey instruments used in the collection of data for the High School and Beyond base year (1980) through the third follow-up surveys (1986) are provided as Volume II of a user's manual for the senior cohort data file. The complete user's manual is designed to provide the extensive documentation necessary for using the cohort data files. Copies of…

  10. Qualities of a psychiatric mentor: a quantitative Singaporean survey.

    PubMed

    Tor, Phern-Chern; Goh, Lee-Gan; Ang, Yong-Guan; Lim, Leslie; Winslow, Rasaiah-Munidasa; Ng, Beng-Yeong; Wong, Sze-Tai; Ng, Tse-Pin; Kia, Ee-Heok

    2011-11-01

    Psychiatric mentors are an important part of the new, seamless training program in Singapore. There is a need to assess the qualities of a good psychiatric mentor vis-à-vis those of a good psychiatrist. An anonymous survey was sent out to all psychiatry trainees and psychiatrists in Singapore to assess quantitatively the relative importance of 40 qualities for a good psychiatrist and a good mentor. The response rate was 48.7% (74/152). Factor analysis showed four themes among the qualities assessed (professional, personal values, relationship, academic-executive). A good mentor is defined by professional, relationship, and personal-values qualities. Mentors have significantly higher scores than psychiatrists for two themes (relationship and academic-executive). Being a good mentor, in Asia, means being a good psychiatrist first and foremost but also requires additional relationship and academic-executive skills. Mentors should be formally trained in these additional skills that were not part of the psychiatric curriculum.

  11. Ten Years of LibQual: A Study of Qualitative and Quantitative Survey Results at the University of Mississippi 2001-2010

    ERIC Educational Resources Information Center

    Greenwood, Judy T.; Watson, Alex P.; Dennis, Melissa

    2011-01-01

    This article analyzes quantitative adequacy gap scores and coded qualitative comments from LibQual surveys at the University of Mississippi from 2001 to 2010, looking for relationships between library policy changes and LibQual results and any other trends that emerged. Analysis found no relationship between changes in policy and survey results…

  12. Reliability and Validity of Survey Instruments to Measure Work-Related Fatigue in the Emergency Medical Services Setting: A Systematic Review

    DOT National Transportation Integrated Search

    2018-01-11

    Background: This study sought to systematically search the literature to identify reliable and valid survey instruments for fatigue measurement in the Emergency Medical Services (EMS) occupational setting. Methods: A systematic review study design wa...

  13. Development and Validation of an Instrument to Measure Students' Motivation and Self-Regulation in Science Learning

    NASA Astrophysics Data System (ADS)

    Velayutham, Sunitadevi; Aldridge, Jill; Fraser, Barry

    2011-10-01

    Students' motivational beliefs and self-regulatory practices have been identified as instrumental in influencing the engagement of students in the learning process. An important aim of science education is to empower students by nurturing the belief that they can succeed in science learning and to cultivate the adaptive learning strategies required to help to bring about that success. This article reports the development and validation of an instrument to measure salient factors related to the motivation and self-regulation of students in lower secondary science classrooms. The development of the instrument involved identifying key determinants of students' motivation and self-regulation in science learning based on theoretical and research underpinnings. Once the instrument was developed, a pilot study involving 52 students from two Grade 8 science classes was undertaken. Quantitative data were collected from 1,360 students in 78 classes across Grades 8, 9, and 10, in addition to in-depth qualitative information gathered from 10 experienced science teachers and 12 Grade 8 students. Analyses of the data suggest that the survey has strong construct validity when used with lower secondary students. This survey could be practically valuable as a tool for gathering information that may guide classroom teachers in refocusing their teaching practices and help to evaluate the effectiveness of intervention programmes.

  14. Quantitative survey on health and violence endured by refugees during their journey and in Calais, France

    PubMed Central

    Bouhenia, Malika; Farhat, Jihane Ben; Coldiron, Matthew E; Abdallah, Saif; Visentin, Delphine; Neuman, Michaël; Berthelot, Mathilde; Porten, Klaudia; Cohuet, Sandra

    2017-01-01

    Abstract Background In 2015, more than 1 million refugees arrived in Europe. During their travels, refugees often face harsh conditions, violence and torture in transit countries, but there is a lack of quantitative evidence on their experiences. We present the results of a retrospective survey among refugees in the ‘Jungle’ of Calais, France, to document their health problems and the violence they endured during their journeys. Methods We conducted a cross-sectional population-based survey in November and December 2015. The sample size was set at 402 individuals, and geospatial simple random sampling was used. We collected data on demographics, routes travelled, health status, violence and future plans. Results Departures from the country of origin increased beginning in September 2015. Sixty-one percent of respondents reported having at least one health problem, especially while in Calais. Overall, 65.6% (95% CI 60.3–70.6) experienced at least one violent event en route; 81.5% of refugees wanted to go to the UK. Conclusions This first quantitative survey conducted among refugees in Europe provides important socio-demographic data on refugees living in Calais and describes the high rate of violence they encountered during their journeys. Similar documentation should be repeated throughout Europe in order to better respond to the needs of this vulnerable population. PMID:29325099

  15. Instrumentation '79.

    ERIC Educational Resources Information Center

    Chemical and Engineering News, 1979

    1979-01-01

    Surveys the state of commerical development of analytical instrumentation as reflected by the Pittsburgh Conference on Analytical Chemistry and Applied Spectroscopy. Includes optical spectroscopy, liquid chromatography, magnetic spectrometers, and x-ray. (Author/MA)

  16. Barriers to global health development: An international quantitative survey

    PubMed Central

    2017-01-01

    Background Global health’s goal of reducing low-and-middle-income country versus high-income country health disparities faces complex challenges. Although there have been discussions of barriers, there has not been a broad-based, quantitative survey of such barriers. Methods 432 global health professionals were invited via email to participate in an online survey, with 268 (62%) participating. The survey assessed participants’ (A) demographic and global health background, (B) perceptions regarding 66 barriers’ seriousness, (C) detailed ratings of barriers designated most serious, (D) potential solutions. Results Thirty-four (of 66) barriers were seen as moderately or more serious, highlighting the widespread, significant challenges global health development faces. Perceived barrier seriousness differed significantly across domains: Resource Limitations mean = 2.47 (0–4 Likert scale), Priority Selection mean = 2.20, Corruption, Lack of Competence mean = 1.87, Social and Cultural Barriers mean = 1.68. Some system-level predictors showed significant but relatively limited relations. For instance, for Global Health Domain, HIV and Mental Health had higher levels of perceived Social and Cultural Barriers than other GH Domains. Individual–level global health experience predictors had small but significant effects, with seriousness of (a) Corruption, Lack of Competence, and (b) Priority Selection barriers positively correlated with respondents’ level of LMIC-oriented (e.g., weeks/year spent in LMIC) but Academic Global Health Achievement (e.g., number of global health publications) negatively correlated with overall barrier seriousness. Conclusions That comparatively few system-level predictors (e.g., Organization Type) were significant suggests these barriers may be relatively fundamental at the system-level. Individual-level and system-level effects do have policy implications; e.g., Priority Selection barriers were among the most serious, yet effects on

  17. Barriers to global health development: An international quantitative survey.

    PubMed

    Weiss, Bahr; Pollack, Amie Alley

    2017-01-01

    Global health's goal of reducing low-and-middle-income country versus high-income country health disparities faces complex challenges. Although there have been discussions of barriers, there has not been a broad-based, quantitative survey of such barriers. 432 global health professionals were invited via email to participate in an online survey, with 268 (62%) participating. The survey assessed participants' (A) demographic and global health background, (B) perceptions regarding 66 barriers' seriousness, (C) detailed ratings of barriers designated most serious, (D) potential solutions. Thirty-four (of 66) barriers were seen as moderately or more serious, highlighting the widespread, significant challenges global health development faces. Perceived barrier seriousness differed significantly across domains: Resource Limitations mean = 2.47 (0-4 Likert scale), Priority Selection mean = 2.20, Corruption, Lack of Competence mean = 1.87, Social and Cultural Barriers mean = 1.68. Some system-level predictors showed significant but relatively limited relations. For instance, for Global Health Domain, HIV and Mental Health had higher levels of perceived Social and Cultural Barriers than other GH Domains. Individual-level global health experience predictors had small but significant effects, with seriousness of (a) Corruption, Lack of Competence, and (b) Priority Selection barriers positively correlated with respondents' level of LMIC-oriented (e.g., weeks/year spent in LMIC) but Academic Global Health Achievement (e.g., number of global health publications) negatively correlated with overall barrier seriousness. That comparatively few system-level predictors (e.g., Organization Type) were significant suggests these barriers may be relatively fundamental at the system-level. Individual-level and system-level effects do have policy implications; e.g., Priority Selection barriers were among the most serious, yet effects on seriousness of how LMIC-oriented a professional was

  18. A comparative review of measurement instruments to inform and evaluate effectiveness of disability inclusive development.

    PubMed

    Goujon, Nicolas; Devine, Alexandra; Baker, Sally M; Sprunt, Beth; Edmonds, Tanya J; Booth, Jennifer K; Keeffe, Jill E

    2014-01-01

    A review of existing measurement instruments was conducted to examine their suitability to measure disability prevalence and assess quality of life, protection of disability rights and community participation by people with disabilities, specifically within the context of development programs in low and middle-income countries. From a search of PubMed and the grey literature, potentially relevant measurement instruments were identified and examined for their content and psychometric properties, where possible. Criteria for inclusion were: based on the WHO's International Classification of Functioning Disability and Health (ICF), used quantitative methods, suitable for population-based studies of disability inclusive development in English and published after 1990. Characteristics of existing instruments were analysed according to components of the ICF and quality of life domains. Ten instruments were identified and reviewed according to the criteria listed above. Each version of instruments was analysed separately. Only three instruments included a component on quality of life. Domains from the ICF that were addressed by some but not all instruments included the environment, technology and communication. The measurement instruments reviewed covered the range of elements required to measure disability-inclusion within development contexts. However no single measurement instrument has the capacity to measure both disability prevalence and changes in quality of life according to contemporary disability paradigms. The review of measurement instruments supports the need for developing an instrument specifically intended to measure disability inclusive practice within development programs. Implications for Rehabilitation Surveys and tools are needed to plan disability inclusive development. Existing measurement tools to determine prevalence of disability, wellbeing, rights and access to the community were reviewed. No single validated tool exists for population

  19. INERTIAL INSTRUMENT SYSTEM FOR AERIAL SURVEYING.

    USGS Publications Warehouse

    Brown, Russell H.; Chapman, William H.; Hanna, William F.; Mongan, Charles E.; Hursh, John W.

    1987-01-01

    The purpose of this report is to describe an inertial guidance or navigation system that will enable use of relatively light aircraft for efficient data-gathering in geologgy, hydrology, terrain mapping, and gravity-field mapping. The instrument system capitalizes not only on virtual state-of-the-art inertial guidance technology but also on similarly advanced technology for measuring distance with electromagnetic radiating devices. The distance measurement can be made with a transceiver beamed at either a cooperative taget, with a specially designed reflecting surface, or a noncooperative target, such as the Earth's surface. The instrument system features components that use both techniques. Thus, a laser tracker device, which updates the inertial guidance unit or navigator in flight, makes distance measurements to a retroreflector target mounted at a ground-control point; a laser profiler device, beamed vertically downward, makes distance measurements to the Earth's surface along a path that roughly mirrors the aircraft flight path.

  20. Utilization of Quantitative EEG Trends for Critical Care Continuous EEG Monitoring: A Survey of Neurophysiologists.

    PubMed

    Swisher, Christa B; Sinha, Saurabh R

    2016-12-01

    Quantitative EEG (QEEG) can be used to assist with review of large amounts of data generated by critical care continuous EEG monitoring. This study aimed to identify current practices regarding the use of QEEG in critical care continuous EEG monitoring of critical care patients. An online survey was sent to 796 members of the American Clinical Neurophysiology Society (ACNS), instructing only neurophysiologists to participate. The survey was completed by 75 neurophysiologists that use QEEG in their practice. Survey respondents reported that neurophysiologists and neurophysiology fellows are most likely to serve as QEEG readers (97% and 52%, respectively). However, 21% of respondents reported nonneurophysiologists are also involved with QEEG interpretation. The majority of nonneurophysiologist QEEG data review is aimed to alert neurophysiologists to periods of concern, but 22% reported that nonneurophysiologists use QEEG to directly guide clinical care. Quantitative EEG was used most frequently for seizure detection (92%) and burst suppression monitoring (59%). A smaller number of respondents use QEEG for monitoring the depth of sedation (29%), ischemia detection (28%), vasospasm detection (28%) and prognosis after cardiac arrest (21%). About half of the respondents do not review every page of the raw critical care continuous EEG record when using QEEG. Respondents prefer a panel of QEEG trends displayed as hemispheric data, when applicable. There is substantial variability regarding QEEG trend preferences for seizure detection and ischemia detection. QEEG is being used by neurophysiologists and nonneurophysiologists for applications beyond seizure detection, but practice patterns vary widely. There is a need for standardization of QEEG methods and practices.

  1. New instrument for measuring student beliefs about physics and learning physics: The Colorado Learning Attitudes about Science Survey

    NASA Astrophysics Data System (ADS)

    Adams, W. K.; Perkins, K. K.; Podolefsky, N. S.; Dubson, M.; Finkelstein, N. D.; Wieman, C. E.

    2006-06-01

    The Colorado Learning Attitudes about Science Survey (CLASS) is a new instrument designed to measure student beliefs about physics and about learning physics. This instrument extends previous work by probing additional aspects of student beliefs and by using wording suitable for students in a wide variety of physics courses. The CLASS has been validated using interviews, reliability studies, and extensive statistical analyses of responses from over 5000 students. In addition, a new methodology for determining useful and statistically robust categories of student beliefs has been developed. This paper serves as the foundation for an extensive study of how student beliefs impact and are impacted by their educational experiences. For example, this survey measures the following: that most teaching practices cause substantial drops in student scores; that a student’s likelihood of becoming a physics major correlates with their “Personal Interest” score; and that, for a majority of student populations, women’s scores in some categories, including “Personal Interest” and “Real World Connections,” are significantly different from men’s scores.

  2. The Therapeutic Environment Screening Survey for Nursing Homes (TESS-NH): an observational instrument for assessing the physical environment of institutional settings for persons with dementia.

    PubMed

    Sloane, Philip D; Mitchell, C Madeline; Weisman, Gerald; Zimmerman, Sheryl; Foley, Kristie M Long; Lynn, Mary; Calkins, Margaret; Lawton, M Powell; Teresi, Jeanne; Grant, Leslie; Lindeman, David; Montgomery, Rhonda

    2002-03-01

    To develop an observational instrument that describes the ability of physical environments of institutional settings to address therapeutic goals for persons with dementia. A National Institute on Aging workgroup identified and subsequently revised items that evaluated exit control, maintenance, cleanliness, safety, orientation/cueing, privacy, unit autonomy, outdoor access, lighting, noise, visual/tactile stimulation, space/seating, and familiarity/homelikeness. The final instrument contains 84 discrete items and one global rating. A summary scale, the Special Care Unit Environmental Quality Scale (SCUEQS), consists of 18 items. Lighting items were validated using portable light meters. Concurrent criterion validation compared SCUEQS scores with the Professional Environmental Assessment Protocol (PEAP). Interrater kappa statistics for 74% of items were above.60. For another 10% of items, kappas could not be calculated due to empty cells, but interrater agreement was above 80%. The SCUEQS demonstrated an interrater reliability of.93, a test--retest reliability of.88, and an internal consistency of.81--.83. Light meter ratings correlated significantly with the Therapeutic Environment Screening Survey for Nursing Homes (TESS-NH) lighting items (r =.29--.38, p =.01--.04), and the SCUEQS correlated significantly with global PEAP ratings (r =.52, p <.01). The TESS-NH efficiently assesses discrete elements of the physical environment and has strong reliability and validity. The SCUEQS provides a quantitative measure of environmental quality in institutional settings.

  3. Aircraft Speed Instruments

    NASA Technical Reports Server (NTRS)

    Beij, K Hilding

    1933-01-01

    This report presents a concise survey of the measurement of air speed and ground speed on board aircraft. Special attention is paid to the pitot-static air-speed meter which is the standard in the United States for airplanes. Air-speed meters of the rotating vane type are also discussed in considerable detail on account of their value as flight test instruments and as service instruments for airships. Methods of ground-speed measurement are treated briefly, with reference to the more important instruments. A bibliography on air-speed measurement concludes the report.

  4. Quantitative Laughter Detection, Measurement, and Classification-A Critical Survey.

    PubMed

    Cosentino, Sarah; Sessa, Salvatore; Takanishi, Atsuo

    2016-01-01

    The study of human nonverbal social behaviors has taken a more quantitative and computational approach in recent years due to the development of smart interfaces and virtual agents or robots able to interact socially. One of the most interesting nonverbal social behaviors, producing a characteristic vocal signal, is laughing. Laughter is produced in several different situations: in response to external physical, cognitive, or emotional stimuli; to negotiate social interactions; and also, pathologically, as a consequence of neural damage. For this reason, laughter has attracted researchers from many disciplines. A consequence of this multidisciplinarity is the absence of a holistic vision of this complex behavior: the methods of analysis and classification of laughter, as well as the terminology used, are heterogeneous; the findings sometimes contradictory and poorly documented. This survey aims at collecting and presenting objective measurement methods and results from a variety of different studies in different fields, to contribute to build a unified model and taxonomy of laughter. This could be successfully used for advances in several fields, from artificial intelligence and human-robot interaction to medicine and psychiatry.

  5. Development of a Biological Science Quantitative Reasoning Exam (BioSQuaRE)

    PubMed Central

    Stanhope, Liz; Ziegler, Laura; Haque, Tabassum; Le, Laura; Vinces, Marcelo; Davis, Gregory K.; Zieffler, Andrew; Brodfuehrer, Peter; Preest, Marion; M. Belitsky, Jason; Umbanhowar, Charles; Overvoorde, Paul J.

    2017-01-01

    Multiple reports highlight the increasingly quantitative nature of biological research and the need to innovate means to ensure that students acquire quantitative skills. We present a tool to support such innovation. The Biological Science Quantitative Reasoning Exam (BioSQuaRE) is an assessment instrument designed to measure the quantitative skills of undergraduate students within a biological context. The instrument was developed by an interdisciplinary team of educators and aligns with skills included in national reports such as BIO2010, Scientific Foundations for Future Physicians, and Vision and Change. Undergraduate biology educators also confirmed the importance of items included in the instrument. The current version of the BioSQuaRE was developed through an iterative process using data from students at 12 postsecondary institutions. A psychometric analysis of these data provides multiple lines of evidence for the validity of inferences made using the instrument. Our results suggest that the BioSQuaRE will prove useful to faculty and departments interested in helping students acquire the quantitative competencies they need to successfully pursue biology, and useful to biology students by communicating the importance of quantitative skills. We invite educators to use the BioSQuaRE at their own institutions. PMID:29196427

  6. Systematic assessment of survey scan and MS2-based abundance strategies for label-free quantitative proteomics using high-resolution MS data.

    PubMed

    Tu, Chengjian; Li, Jun; Sheng, Quanhu; Zhang, Ming; Qu, Jun

    2014-04-04

    Survey-scan-based label-free method have shown no compelling benefit over fragment ion (MS2)-based approaches when low-resolution mass spectrometry (MS) was used, the growing prevalence of high-resolution analyzers may have changed the game. This necessitates an updated, comparative investigation of these approaches for data acquired by high-resolution MS. Here, we compared survey scan-based (ion current, IC) and MS2-based abundance features including spectral-count (SpC) and MS2 total-ion-current (MS2-TIC), for quantitative analysis using various high-resolution LC/MS data sets. Key discoveries include: (i) study with seven different biological data sets revealed only IC achieved high reproducibility for lower-abundance proteins; (ii) evaluation with 5-replicate analyses of a yeast sample showed IC provided much higher quantitative precision and lower missing data; (iii) IC, SpC, and MS2-TIC all showed good quantitative linearity (R(2) > 0.99) over a >1000-fold concentration range; (iv) both MS2-TIC and IC showed good linear response to various protein loading amounts but not SpC; (v) quantification using a well-characterized CPTAC data set showed that IC exhibited markedly higher quantitative accuracy, higher sensitivity, and lower false-positives/false-negatives than both SpC and MS2-TIC. Therefore, IC achieved an overall superior performance than the MS2-based strategies in terms of reproducibility, missing data, quantitative dynamic range, quantitative accuracy, and biomarker discovery.

  7. Systematic Assessment of Survey Scan and MS2-Based Abundance Strategies for Label-Free Quantitative Proteomics Using High-Resolution MS Data

    PubMed Central

    2015-01-01

    Survey-scan-based label-free method have shown no compelling benefit over fragment ion (MS2)-based approaches when low-resolution mass spectrometry (MS) was used, the growing prevalence of high-resolution analyzers may have changed the game. This necessitates an updated, comparative investigation of these approaches for data acquired by high-resolution MS. Here, we compared survey scan-based (ion current, IC) and MS2-based abundance features including spectral-count (SpC) and MS2 total-ion-current (MS2-TIC), for quantitative analysis using various high-resolution LC/MS data sets. Key discoveries include: (i) study with seven different biological data sets revealed only IC achieved high reproducibility for lower-abundance proteins; (ii) evaluation with 5-replicate analyses of a yeast sample showed IC provided much higher quantitative precision and lower missing data; (iii) IC, SpC, and MS2-TIC all showed good quantitative linearity (R2 > 0.99) over a >1000-fold concentration range; (iv) both MS2-TIC and IC showed good linear response to various protein loading amounts but not SpC; (v) quantification using a well-characterized CPTAC data set showed that IC exhibited markedly higher quantitative accuracy, higher sensitivity, and lower false-positives/false-negatives than both SpC and MS2-TIC. Therefore, IC achieved an overall superior performance than the MS2-based strategies in terms of reproducibility, missing data, quantitative dynamic range, quantitative accuracy, and biomarker discovery. PMID:24635752

  8. Accuracy of responses from postal surveys about continuing medical education and information behavior: experiences from a survey among German diabetologists

    PubMed Central

    Trelle, Sven

    2002-01-01

    Background Postal surveys are a popular instrument for studies about continuing medical education habits. But little is known about the accuracy of responses in such surveys. The objective of this study was to quantify the magnitude of inaccurate responses in a postal survey among physicians. Methods A sub-analysis of a questionnaire about continuing medical education habits and information management was performed. The five variables used for the quantitative analysis are based on a question about the knowledge of a fictitious technical term and on inconsistencies in contingency tables of answers to logically connected questions. Results Response rate was 52%. Non-response bias is possible but seems not very likely since an association between demographic variables and inconsistent responses could not be found. About 10% of responses were inaccurate according to the definition. Conclusion It was shown that a sub-analysis of a questionnaire makes a quantification of inaccurate responses in postal surveys possible. This sub-analysis revealed that a notable portion of responses in a postal survey about continuing medical education habits and information management was inaccurate. PMID:12153701

  9. The Dark Energy Spectroscopic Instrument (DESI)

    NASA Astrophysics Data System (ADS)

    Flaugher, Brenna; Bebek, Chris

    2014-07-01

    The Dark Energy Spectroscopic Instrument (DESI) is a Stage IV ground-based dark energy experiment that will study baryon acoustic oscillations (BAO) and the growth of structure through redshift-space distortions with a wide-area galaxy and quasar spectroscopic redshift survey. The DESI instrument consists of a new wide-field (3.2 deg. linear field of view) corrector plus a multi-object spectrometer with up to 5000 robotically positioned optical fibers and will be installed at prime focus on the Mayall 4m telescope at Kitt Peak, Arizona. The fibers feed 10 three-arm spectrographs producing spectra that cover a wavelength range from 360-980 nm and have resolution of 2000-5500 depending on the wavelength. The DESI instrument is designed for a 14,000 sq. deg. multi-year survey of targets that trace the evolution of dark energy out to redshift 3.5 using the redshifts of luminous red galaxies (LRGs), emission line galaxies (ELGs) and quasars. DESI is the successor to the successful Stage-III BOSS spectroscopic redshift survey and complements imaging surveys such as the Stage-III Dark Energy Survey (DES, currently operating) and the Stage-IV Large Synoptic Survey Telescope (LSST, planned start early in the next decade).

  10. Collection of quantitative chemical release field data.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Demirgian, J.; Macha, S.; Loyola Univ.

    1999-01-01

    Detection and quantitation of chemicals in the environment requires Fourier-transform infrared (FTIR) instruments that are properly calibrated and tested. This calibration and testing requires field testing using matrices that are representative of actual instrument use conditions. Three methods commonly used for developing calibration files and training sets in the field are a closed optical cell or chamber, a large-scale chemical release, and a small-scale chemical release. There is no best method. The advantages and limitations of each method should be considered in evaluating field results. Proper calibration characterizes the sensitivity of an instrument, its ability to detect a component inmore » different matrices, and the quantitative accuracy and precision of the results.« less

  11. Quality of persian addiction websites: a survey based on silberg, discern and wqet instruments (2011).

    PubMed

    Zahedi, Razieh; Taheri, Behjat; Shahrzadi, Leila; Tazhibi, Mehdi; Ashrafi-rizi, Hasan

    2013-03-01

    Nowadays, World Wide Web is an accessible and widespread resource to attain medical information. So physicians and health institutions try to inform patients about different domains of medicine through Web. Addiction is a noteworthy subject in medicine and a controversial issue among them. However, quality of health information on the internet is doubtful. The objective of this study is to determine the quality of Persian addiction websites to offer recommendation for their improvement. This was survey and an applied study that the study population was all Persian addiction websites. Sample of this study was 28 Persian addiction website which were chosen by searching Persian equivalences of 7 key terms (addiction, addict, addiction center, drug, treatment of addiction, recovery of addiction, addiction withdrawal) into the Google and Yahoo search engines. Finally, the websites were ranked based on the Silberg, DISCERN and WQET instruments. Data were analyzed with Excel software using descriptive statistics. The overall mean of websites in Silberg, DISCERN and WQET instruments were 1.42, 41.89, 64.57. Also the results showed that "Unit of Substance Abuse Treatment" belonging to Mashhad University of Medical Sciences was ranked first based on the Silberg, DISCERN and WQET instruments. 5 (from total of 9), 60 (from total of 80) and 82 (from total of normalized grade 82) were grades for this website for these instruments respectively. It showed that the quality of Persian websites according to Silberg, DISCERN and WQET instruments was "low", "more than half" and "very good" respectively. Not assigning date of entering data, author names, and references of information (authority) were most important missing characteristics of these websites. In addition, lack of interactive opportunities like chat rooms was another problem that leads to dissatisfaction of users.

  12. Quality of Persian Addiction Websites: A Survey Based on Silberg, Discern and Wqet Instruments (2011)

    PubMed Central

    Zahedi, Razieh; Taheri, Behjat; Shahrzadi, Leila; Tazhibi, Mehdi; Ashrafi-rizi, Hasan

    2013-01-01

    Background Nowadays, World Wide Web is an accessible and widespread resource to attain medical information. So physicians and health institutions try to inform patients about different domains of medicine through Web. Addiction is a noteworthy subject in medicine and a controversial issue among them. However, quality of health information on the internet is doubtful. The objective of this study is to determine the quality of Persian addiction websites to offer recommendation for their improvement. Methods This was survey and an applied study that the study population was all Persian addiction websites. Sample of this study was 28 Persian addiction website which were chosen by searching Persian equivalences of 7 key terms (addiction, addict, addiction center, drug, treatment of addiction, recovery of addiction, addiction withdrawal) into the Google and Yahoo search engines. Finally, the websites were ranked based on the Silberg, DISCERN and WQET instruments. Data were analyzed with Excel software using descriptive statistics. Results The overall mean of websites in Silberg, DISCERN and WQET instruments were 1.42, 41.89, 64.57. Also the results showed that “Unit of Substance Abuse Treatment” belonging to Mashhad University of Medical Sciences was ranked first based on the Silberg, DISCERN and WQET instruments. 5 (from total of 9), 60 (from total of 80) and 82 (from total of normalized grade 82) were grades for this website for these instruments respectively. Conclusion It showed that the quality of Persian websites according to Silberg, DISCERN and WQET instruments was “low”, “more than half” and “very good” respectively. Not assigning date of entering data, author names, and references of information (authority) were most important missing characteristics of these websites. In addition, lack of interactive opportunities like chat rooms was another problem that leads to dissatisfaction of users. PMID:23572862

  13. Results of qualification tests on water-level sensing instruments, 1986

    USGS Publications Warehouse

    Holland, Randolph R.; Rapp, Donald H.

    1988-01-01

    This report presents to users of hydrological instrumentation and U.S. Geological Survey procurement personnel a list of instruments that have met or exceeded the Survey 's minimum performance requirements for water level sensing instruments. The Hydrologic Instrumentation Facility at the National Space Technology Laboratories, Mississippi conducted qualification tests on four instrument systems. The data collected are summarized, brief system descriptions are given, qualification testing purposes and procedures are summarized, and results are given for each of the three systems that met performance requirements. The fourth system was returned to the manufacturer , because in preliminary testing the instrument system did not perform properly according to the manufacturer 's operating procedures. As a result of the qualification tests, the three systems that met performance requirements have been included on the Survey 's Qualified Products List. (USGS)

  14. Development and pilot testing of an Internet-based survey instrument to measure the alcohol brand preferences of U.S. youth.

    PubMed

    Siegel, Michael; DiLoreto, Joanna; Johnson, Andrea; Fortunato, Erin K; DeJong, William

    2011-04-01

    Although we know a great deal about the percentage of youth who drink alcohol, we know very little about the specific brands they choose to drink. This information gap needs to be addressed if public health officials are to develop more effective interventions. Unfortunately, there are no national youth surveys that collect data on alcohol brand consumption. In this paper, we describe the development and pilot testing of what we believe to be the first comprehensive, Internet-based youth survey of brand-specific alcohol use. We used online advertising in 3 U.S. cities to recruit a convenience sample of 241 respondents, ages 16 to 18 years. We used Craigslist, a network of online communities that features local classified advertisements, to recruit the sample. We used SurveyGizmo, an online software program for designing Internet surveys, collecting data, and performing basic analysis, to survey these respondents about their brand-specific alcohol consumption patterns. The survey instrument assessed each respondent's 30-day drinking history, including the frequency of consumption for each alcohol brand. Using Internet survey technology, we were able to collect information on 366 brands and still have respondents complete the instrument quickly and easily. The total number of brands consumed in the past 30 days ranged from 1 to 18, with a median of 4 brands. The top 5 brands consumed were beer brands, as were eleven of the top 15 brands. The remaining 4 brands in the top 15 included 3 brands of flavored alcoholic beverages and 1 brand of mixed drink. Among the top 15 alcohol brands consumed during heavy drinking episodes were 8 brands of beer, 4 brands of flavored alcoholic beverages, 2 brands of wine, and 1 brand of mixed drink. This pilot study helps establish the feasibility of including brand-specific questions on federal or other national youth alcohol surveys. Copyright © 2011 by the Research Society on Alcoholism.

  15. Use of electronic microprocessor-based instrumentation by the U.S. geological survey for hydrologic data collection

    USGS Publications Warehouse

    Shope, William G.; ,

    1991-01-01

    The U.S. Geological Survey is acquiring a new generation of field computers and communications software to support hydrologic data-collection at field locations. The new computer hardware and software mark the beginning of the Survey's transition from the use of electromechanical devices and paper tapes to electronic microprocessor-based instrumentation. Software is being developed for these microprocessors to facilitate the collection, conversion, and entry of data into the Survey's National Water Information System. The new automated data-collection process features several microprocessor-controlled sensors connected to a serial digital multidrop line operated by an electronic data recorder. Data are acquired from the sensors in response to instructions programmed into the data recorder by the user through small portable lap-top or hand-held computers. The portable computers, called personal field computers, also are used to extract data from the electronic recorders for transport by courier to the office computers. The Survey's alternative to manual or courier retrieval is the use of microprocessor-based remote telemetry stations. Plans have been developed to enhance the Survey's use of the Geostationary Operational Environmental Satellite telemetry by replacing the present network of direct-readout ground stations with less expensive units. Plans also provide for computer software that will support other forms of telemetry such as telephone or land-based radio.

  16. A review of health-related workplace productivity loss instruments.

    PubMed

    Lofland, Jennifer H; Pizzi, Laura; Frick, Kevin D

    2004-01-01

    The objective of this review was to identify health-related workplace productivity loss survey instruments, with particular emphasis on those that capture a metric suitable for direct translation into a monetary figure. A literature search using Medline, HealthSTAR, PsycINFO and Econlit databases between 1966 and 2002, and a telephone-administered survey of business leaders and researchers, were conducted to identify health-related workplace productivity measurement survey instruments. This review was conducted from the societal perspective. Each identified instrument was reviewed for the following: (i). reliability; (ii). content validity; (iii). construct validity; (iv). criterion validity; (v). productivity metric(s); (vi). instrument scoring technique; (vii). suitability for direct translation into a monetary figure; (viii). number of items; (ix). mode(s) of administration; and (x). disease state(s) in which it had been tested. Reliability and validity testing have been performed for 8 of the 11 identified surveys. Of the 11 instruments identified, six captured metrics that are suitable for direct translation into a monetary figure. Of those six, one instrument measured absenteeism, while the other five measured both absenteeism and presenteeism. All of the identified instruments except for one were available as paper, self-administered questionnaires and many were available in languages other than English. This review provides a comprehensive overview of the published, peer-reviewed survey instruments available to measure health-related workplace productivity loss. As the field of productivity measurement matures, tools may be developed that will allow researchers to accurately calculate lost productivity costs when performing cost-effectiveness and cost-benefit analyses. Using data captured by these instruments, society and healthcare decision makers will be able to make better informed decisions concerning the value of the medications, disease management and

  17. Predicting Team Performance through Human Behavioral Sensing and Quantitative Workflow Instrumentation

    DTIC Science & Technology

    2016-07-27

    make risk-informed decisions during serious games . Statistical models of intra- game performance were developed to determine whether behaviors in...specific facets of the gameplay workflow were predictive of analytical performance and games outcomes. A study of over seventy instrumented teams revealed...more accurate game decisions. 2 Keywords: Humatics · Serious Games · Human-System Interaction · Instrumentation · Teamwork · Communication Analysis

  18. [Survey of analytical works for drugs at emergency and critical care centers with high-performance instruments provided by the Ministry of Health and Welfare (at present: Ministry of Health, Labour, and Welfare) in fiscal 1998--continuation of survey with 2008 survey results as point of reference].

    PubMed

    Saito, Takeshi; Tominaga, Aya; Nozawa, Mayu; Unei, Hiroko; Hatano, Yayoi; Fujita, Yuji; Iseki, Ken; Hori, Yasushi

    2013-09-01

    In a 2008 survey of the 73 emergency and critical care centers around the nation that were equipped with the drug and chemical analytical instrument provided by the Ministry of Welfare (currently the Ministry of Health, Labour, and Welfare) in 1998, 36 of those facilities were using the analytical instruments. Of these 36 facilities, a follow-up survey of the 17 facilities that recorded 50 or analyses per year. Responses were gained from 16 of the facilities and we learned that of those, 14 facilities (87.5%) were conducting analyses using the instrument. There was a positive mutual correlation between the annual number of cases of the 14 facilities conducting analyses with the instrument and the number of work hours. Depending on the instrument in use, average analytical instrument parts and maintenance expenses were roughly three million yen and consumables required a maximum three million yen for analysis of 51-200 cases per year. From this, we calculate that such expenses can be covered under the allowed budget for advanced emergency and critical care centers of 5,000 NHI points (1 point = 10 yen). We found there were few facilities using the instrument for all 15 of the toxic substances recommended for testing by the Japanese Society for Clinical Toxicology. There tended to be no use of the analytical instrument for compounds with no toxicology cases. However, flexible responses were noted at each facility in relation to frequently analyzed compounds. It is thought that a reevaluation of compounds subject to analysis is required.

  19. Development of a survey to assess adolescent perceptions of teen parenting.

    PubMed

    Herrman, Judith W; Nandakumar, Ratna

    2012-01-01

    Initiatives designed to prevent teen pregnancy are often based on adult perceptions of the negative aspects of a teen birth. Qualitative research has revealed that teens may perceive positive rewards associated with teen parenting. These perceptions have not yet been examined through survey research. The theory of reasoned action proposes that individuals assess the costs and rewards prior to engaging in a behavior and provides a framework for the development of a survey instrument designed to measure adolescent thoughts about the costs and rewards of the teen parenting experience. This manuscript describes the development and testing of a quantitative survey instrument designed to measure adolescents' perceptions. Pretesting, piloting, exploratory factor analysis, and a variety of reliability and validity measures were used to determine the value of the measure. The thoughts on teen parenting survey (TTPS) demonstrates an alpha level of .90. The TTPS yields a cumulative score of teen perceptions about the impact of a teen birth during the adolescent years that may be used to assess youth beliefs, correlated with demographic data, used to identify teens at risk for pregnancy/parenting, or provide a pretest/posttest to assess the effectiveness of interventions designed to foster realistic attitudes toward teen parenting.

  20. Pancreatitis Quality of Life Instrument: Development of a new instrument

    PubMed Central

    Bova, Carol; Barton, Bruce; Hartigan, Celia

    2014-01-01

    Objectives: The goal of this project was to develop the first disease-specific instrument for the evaluation of quality of life in chronic pancreatitis. Methods: Focus groups and interview sessions were conducted, with chronic pancreatitis patients, to identify items felt to impact quality of life which were subsequently formatted into a paper-and-pencil instrument. This instrument was used to conduct an online survey by an expert panel of pancreatologists to evaluate its content validity. Finally, the modified instrument was presented to patients during precognitive testing interviews to evaluate its clarity and appropriateness. Results: In total, 10 patients were enrolled in the focus groups and interview sessions where they identified 50 items. Once redundant items were removed, the 40 remaining items were made into a paper-and-pencil instrument referred to as the Pancreatitis Quality of Life Instrument. Through the processes of content validation and precognitive testing, the number of items in the instrument was reduced to 24. Conclusions: This marks the development of the first disease-specific instrument to evaluate quality of life in chronic pancreatitis. It includes unique features not found in generic instruments (economic factors, stigma, and spiritual factors). Although this marks a giant step forward, psychometric evaluation is still needed prior to its clinical use. PMID:26770703

  1. Instrument Pointing Capabilities: Past, Present, and Future

    NASA Technical Reports Server (NTRS)

    Blackmore, Lars; Murray, Emmanuell; Scharf, Daniel P.; Aung, Mimi; Bayard, David; Brugarolas, Paul; Hadaegh, Fred; Lee, Allan; Milman, Mark; Sirlin, Sam; hide

    2011-01-01

    This paper surveys the instrument pointing capabilities of past, present and future space telescopes and interferometers. As an important aspect of this survey, we present a taxonomy for "apples-to-apples" comparisons of pointing performances. First, pointing errors are defined relative to either an inertial frame or a celestial target. Pointing error can then be further sub-divided into DC, that is, steady state, and AC components. We refer to the magnitude of the DC error relative to the inertial frame as absolute pointing accuracy, and we refer to the magnitude of the DC error relative to a celestial target as relative pointing accuracy. The magnitude of the AC error is referred to as pointing stability. While an AC/DC partition is not new, we leverage previous work by some of the authors to quantitatively clarify and compare varying definitions of jitter and time window averages. With this taxonomy and for sixteen past, present, and future missions, pointing accuracies and stabilities, both required and achieved, are presented. In addition, we describe the attitude control technologies used to and, for future missions, planned to achieve these pointing performances.

  2. A Robot or a Science Instrument?

    NASA Image and Video Library

    2009-10-20

    Some say the science instrument on NASA Wide-field Infrared Survey Explorer mission resembles the Star Wars robot R2-D2. The instrument is enclosed in a solid-hydrogen cryostat, which cools the WISE telescope and detectors.

  3. Psychometric Analysis and Qualitative Review of an Outpatient Radiology-Specific Patient Satisfaction Survey: A Call for Collaboration in Validating a Survey Instrument.

    PubMed

    Dibble, Elizabeth H; Baird, Grayson L; Swenson, David W; Healey, Terrance T

    2017-10-01

    The aim of this study was to perform a psychometric analysis of the constructs and reliability of an outpatient radiology-specific patient satisfaction survey and identify factors that drive patient experience so that radiology practices can improve the quality of their diagnostic imaging services. This retrospective study examined responses to eight patient satisfaction questions from a survey originally developed by a nascent marketing team and then administered at five outpatient imaging centers from January 7, 2013, to November 11, 2015. Patients' responses were reviewed to identify factors that affected patient experience, and a psychometric analysis of the survey instrument itself was performed, including exploratory factor analyses and reliability testing. Patient responses were compared among sites, examination types, and questions. Free-text comments were qualitatively categorized and compared by examination type. In total, 6,512 surveys were completed among 137,059 patient encounters. Using exploratory factor analyses of the eight survey questions, three relevant patient experience constructs were derived: (1) front office experience, (2) intake experience, and (3) examination experience. Overall, good scale reliability was observed. Perceived quality of care had the most positive ratings; wait time had the most nonpositive ratings. Of 2,024 free-text comments, 1,859 were positive (most pertaining to staff), and 155 were negative (most pertaining to convenience). MRI patients were most likely to share negative comments, typically regarding the examination experience itself. Psychometric analysis of a patient survey derived three core patient experience constructs: front office experience, intake experience, and examination experience. The survey indicates the need to decrease wait times, streamline the registration process, and improve patient comfort during MRI examinations. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All

  4. Evaluation of an immunosuppressant side effect instrument.

    PubMed

    Winsett, Rebecca P; Arheart, Kris; Stratta, Robert J; Alloway, Rita; Wicks, Mona N; Gaber, A Osama; Hathaway, Donna K

    2004-09-01

    Clinicians continue to be compelled to evaluate the impact of immunosuppressive medication side effects on the quality of life of transplant recipients. We Were asked to develop an instrument to measure side effects in immunosuppressed transplant recipients. To construct an instrument that measures the impact and severity of side effects of immunosuppressive medications used in transplantation and to assess the reliability and validity of the newly developed instrument called the Memphis Survey. The instrument was constructed by a panel of physicians, nurses, and pharmacists with experience in treating transplant recipients. A small group of kidney transplant recipients (n= 13) provided pilot data for refining and testing the instrument. A national sample of kidney, liver, and heart transplant recipients (n = 505) provided data that were used to further develop the instrument. Factor analysis was used to determine the psychological dimensions underlying the instrument and to guide the construction of scales from the survey items. The instrument scales were then computed from the dataset of 505 transplant recipients to quantify the impact of immunosuppressant side effects on the quality of life of transplant recipients. Analyses showed the final instrument scales to be valid and reliable. Exploratory analysis suggests the need for further testing of the instrument to determine gender differences.

  5. Development of a Survey to Examine the Factors That Motivate Secondary Education Teachers' Use of Problem-Based Learning (PBL)

    ERIC Educational Resources Information Center

    Lao, Huei-Chen

    2016-01-01

    In this quantitative study, a survey was developed and administered to middle and high school teachers to examine what factors motivated them to implement problem-based learning (PBL). Using Expectancy-Value Theory by Eccles et al. (1983) and Self-Determination Theory by Ryan and Deci (2000b) as the theoretical framework, this instrument measured…

  6. Population and Star Formation Histories from the Outer Limits Survey

    NASA Astrophysics Data System (ADS)

    Brondel, Brian Joseph; Saha, Abhijit; Olszewski, Edward

    2015-08-01

    The Outer Limits Survey (OLS) is a deep survey of selected fields in the outlying areas of the Magellanic Clouds based on the MOSAIC-II instrument on the Blanco 4-meter Telescope at CTIO. OLS is designed to probe the outer disk and halo structures of Magellanic System. The survey comprises ~50 fields obtained in Landolt R, I and Washington C, M and DDO51 filters, extending to a depth of about 24th magnitude in I. While qualitative examination of the resulting data has yielded interesting published results, we report here on quantitative analysis through matching of Hess diagrams to theoretical isochrones. We present analysis based on techniques developed by Dolphin (e.g., 2002, MNRAS, 332, 91) for fields observed by OLS. Our results broadly match those found by qualitative examination of the CMDs, but interesting details emerge from isochrone fitting.

  7. Principles of survey development for telemedicine applications.

    PubMed

    Demiris, George

    2006-01-01

    Surveys can be used in the evaluation of telemedicine applications but they must be properly designed, consistent and accurate. The purpose of the survey and the resources available will determine the extent of testing that a survey instrument should undergo prior to its use. The validity of an instrument is the correspondence between what is being measured and what was intended to be measured. The reliability of an instrument describes the 'consistency' or 'repeatability' of the measurements made with it. Survey instruments should be designed and tested following basic principles of survey development. The actual survey administration also requires consideration, for example data collection and processing, as well as the interpretation of the findings. Surveys are of two different types. Either they are self-administered, or they are administered by interview. In the latter case, they may be administered by telephone or in a face-to-face meeting. It is important to design a survey instrument based on a detailed definition of what it intends to measure and to test it before administering it to the larger sample.

  8. Domestic violence against women in India: A systematic review of a decade of quantitative studies.

    PubMed

    Kalokhe, Ameeta; Del Rio, Carlos; Dunkle, Kristin; Stephenson, Rob; Metheny, Nicholas; Paranjape, Anuradha; Sahay, Seema

    2017-04-01

    Domestic violence (DV) is prevalent among women in India and has been associated with poor mental and physical health. We performed a systematic review of 137 quantitative studies published in the prior decade that directly evaluated the DV experiences of Indian women to summarise the breadth of recent work and identify gaps in the literature. Among studies surveying at least two forms of abuse, a median 41% of women reported experiencing DV during their lifetime and 30% in the past year. We noted substantial inter-study variance in DV prevalence estimates, attributable in part to different study populations and settings, but also to a lack of standardisation, validation, and cultural adaptation of DV survey instruments. There was paucity of studies evaluating the DV experiences of women over age 50, residing in live-in relationships, same-sex relationships, tribal villages, and of women from the northern regions of India. Additionally, our review highlighted a gap in research evaluating the impact of DV on physical health. We conclude with a research agenda calling for additional qualitative and longitudinal quantitative studies to explore the DV correlates proposed by this quantitative literature to inform the development of a culturally tailored DV scale and prevention strategies.

  9. Domestic violence against women in India: A systematic review of a decade of quantitative studies

    PubMed Central

    Kalokhe, Ameeta; del Rio, Carlos; Dunkle, Kristin; Stephenson, Rob; Metheny, Nicholas; Paranjape, Anuradha; Sahay, Seema

    2016-01-01

    Domestic violence (DV) is prevalent among women in India and has been associated with poor mental and physical health. We performed a systematic review of 137 quantitative studies published in the prior decade that directly evaluated the DV experiences of Indian women to summarise the breadth of recent work and identify gaps in the literature. Among studies surveying at least two forms of abuse, a median 41% of women reported experiencing DV during their lifetime and 30% in the past year. We noted substantial inter-study variance in DV prevalence estimates, attributable in part to different study populations and settings, but also to a lack of standardisation, validation, and cultural adaptation of DV survey instruments. There was paucity of studies evaluating the DV experiences of women over age 50, residing in live-in relationships, same-sex relationships, tribal villages, and of women from the northern regions of India. Additionally, our review highlighted a gap in research evaluating the impact of DV on physical health. We conclude with a research agenda calling for additional qualitative and longitudinal quantitative studies to explore the DV correlates proposed by this quantitative literature to inform the development of a culturally tailored DV scale and prevention strategies. PMID:26886155

  10. Instrument Selection for Randomized Controlled Trials Why This and Not That?

    PubMed Central

    Records, Kathie; Keller, Colleen; Ainsworth, Barbara; Permana, Paska

    2011-01-01

    A fundamental linchpin for obtaining rigorous findings in quantitative research involves the selection of survey instruments. Psychometric recommendations are available for the processes for scale development and testing and guidance for selection of established scales. These processes are necessary to address the validity link between the phenomena under investigation, the empirical measures and, ultimately, the theoretical ties between these and the world views of the participants. Detailed information is most often provided about study design and protocols, but far less frequently is a detailed theoretical explanation provided for why specific instruments are chosen. Guidance to inform choices is often difficult to find when scales are needed for specific cultural, ethnic, or racial groups. This paper details the rationale underlying instrument selection for measurement of the major processes (intervention, mediator and moderator variables, outcome variables) in an ongoing study of postpartum Latinas, Madres para la Salud [Mothers for Health]. The rationale underpinning our choices includes a discussion of alternatives, when appropriate. These exemplars may provide direction for other intervention researchers who are working with specific cultural, racial, or ethnic groups or for other investigators who are seeking to select the ‘best’ instrument. Thoughtful consideration of measurement and articulation of the rationale underlying our choices facilitates the maintenance of rigor within the study design and improves our ability to assess study outcomes. PMID:21986392

  11. Assessing healthcare professionals' experiences of integrated care: do surveys tell the full story?

    PubMed

    Stephenson, Matthew D; Campbell, Jared M; Lisy, Karolina; Aromataris, Edoardo C

    2017-09-01

    Integrated care is the combination of different healthcare services with the goal to provide comprehensive, seamless, effective and efficient patient care. Assessing the experiences of healthcare professionals (HCPs) is an important aspect when evaluating integrated care strategies. The aim of this rapid review was to investigate if quantitative surveys used to assess HCPs' experiences with integrated care capture all the aspects highlighted as being important in qualitative research, with a view to informing future survey development. The review considered all types of health professionals in primary care, and hospital and specialist services, with a specific focus on the provision of integrated care aimed at improving the patient journey. PubMed, CINAHL and grey literature sources were searched for relevant surveys/program evaluations and qualitative research studies. Full text articles deemed to be of relevance to the review were appraised for methodological quality using abridged critical appraisal instruments from the Joanna Briggs Institute. Data were extracted from included studies using standardized data extraction templates. Findings from included studies were grouped into domains based on similarity of meaning. Similarities and differences in the domains covered in quantitative surveys and those identified as being important in qualitative research were explored. A total of 37 studies (19 quantitative surveys, 14 qualitative studies and four mixed-method studies) were included in the review. A range of healthcare professions participated in the included studies, the majority being primary care providers. Common domains identified from quantitative surveys and qualitative studies included Communication, Agreement on Clear Roles and Responsibilities, Facilities, Information Systems, and Coordination of Care and Access. Qualitative research highlighted domains identified by HCPs as being relevant to their experiences with integrated care that have not

  12. Psychometric properties of the WHO Violence Against Women instrument in a female population-based sample in Sweden: a cross-sectional survey

    PubMed Central

    Nybergh, Lotta; Taft, Charles; Krantz, Gunilla

    2013-01-01

    Objective To explore psychometric properties of the Violence Against Women instrument in a randomly selected national sample of women (N=573) aged 18–65 years and residing in Sweden. Design Cross-sectional survey study. Setting Sweden. Participants A postal survey was sent to 1006 women between January and March 2009, during which 624 women (62%) returned the questionnaire. 51 women who did not answer any of the violence items were excluded from the analyses, resulting in a final sample of 573 women. Primary and secondary outcome measures Self-reported exposure to psychological, physical and sexual intimate partner violence. Results Cronbach's α coefficients were 0.79 (psychological scale), 0.80 (physical scale), 0.72 (sexual scale) and 0.88 (total scale). A predetermined three-component solution largely replicated the explored three component conceptual model of the Violence Against Women instrument. The instrument was able to discriminate between groups known from previous studies to differ in exposure to physical and/or sexual violence, that is, respondents with poor versus good self-rated health and witnessed versus not witnessed physical violence at home when growing up. Past-year prevalence of physical (8.1%; 95% CI 5.9 to 10.3) and sexual (3%; 1.6 to 4.4) violence was similar to that reported in other Nordic studies; however, earlier-in-life prevalence was lower in the current study (14.3%; 95% CI 11.4 to 17.2 and 9.2%; 95% CI 6.8 to 11.6, respectively). Reported exposure rates were higher than those obtained from a concurrently administered instrument (NorVold Abuse Questionnaire). Conclusions The Violence Against Women instrument demonstrated good construct validity and internal reliability in an adult female population in Sweden. However, further studies examining these and other psychometric properties need to be conducted in other countries. PMID:23793692

  13. Dental Management Survey Brazil (DMS-BR): creation and validation of a management instrument

    PubMed

    Gonzales, Paola Sampaio; Martins, Ismar Eduardo; Biazevic, Maria Gabriela Haye; Silva, Paulo Roberto da; Michel-Crosato, Edgard

    2017-04-10

    Questionnaires for the assessment of knowledge and self-perception can be useful to diagnose what a dentist knows about management and administration. The aim of the present study was to create and validate the Dental Management Survey Brazil (DMS-BR) scale, based on meetings with experts in the field. After having elaborated the first version, 10 audits were performed in dental offices in order to produce the final version, which included nine dimensions: location, patient, finance, marketing, competition, quality, staff, career, and productivity. The accuracy of the instrument was measured by intrarater and interrater reliability. In the validation phase, 247 Brazilian dentists answered a web-based questionnaire. The data were processed using Stata 13.0 and the significance level was set at 95%. The instrument had intrarater and interrater reliability (ICC-0.93 and 0.94). The overall average of respondents for the DMS-BR scale was 3.77 (SD = 0.45). Skewness and kurtosis were below absolute values 3 and 7, respectively. Internal validity measured by Cronbach's alpha was 0.925 and the correlation of each dimension with the final result of the DMS-BR ranged between 0.606 and 0.810. Correlation with the job satisfaction scale was 0.661. The SEM data ranged between 0.80 and 0.56. The questionnaire presented satisfactory indicators of dentists' self-perception about management and administration activities.

  14. Instrumentation Guidelines for the Advanced National Seismic System

    USGS Publications Warehouse

    Working Group on Instrumentation, Siting

    2008-01-01

    This document provides guidelines for the seismic-monitoring instrumentation used by long-term earthquake-monitoring stations that will sense ground motion, digitize and store the resulting signals in a local data acquisition unit, and optionally transmit these digital data. These guidelines are derived from specifications and requirements for data needed to address the nation's emergency response, engineering, and scientific needs as identified in U.S. Geological Survey Circular 1188 (1999). Data needs are discussed in terms of national, regional, and urban scales of monitoring in section 3. Functional performance specifications for instrumentation are introduced in section 4.3 and discussed in detail in section 6 in terms of instrument classes and definitions described in section 5. System aspects and testing recommendations are discussed in sections 7 and 8, respectively. Although U.S. Geological Survey Circular 1188 (1999) recommends that the Advanced National Seismic System (ANSS) include portable instrumentation, performance specifications for this element are not specifically addressed in this document. Nevertheless, these guidelines are largely applicable to portable instrumentation. Volcano monitoring instrumentation is also beyond the scope of this document. Guidance for ANSS structural-response monitoring is discussed briefly herein but details are deferred to the ANSS document by the ANSS Structural Response Monitoring Committee (U.S. Geological Survey, 2005). Aspects of station planning, siting, and installation other than instrumentation are beyond the scope of this document.

  15. Results from the calibration of the Extreme Ultraviolet Explorer instruments

    NASA Technical Reports Server (NTRS)

    Welsh, Barry Y.; Jelinsky, Pat; Vedder, Peter W.; Vallerga, John V.; Finley, David S.; Malina, Roger F.

    1991-01-01

    The paper describes the main features and selected results of the calibration of the scientific instruments to be flown on the Extreme Ultraviolet Explorer in 1991. The instrument payload includes three grazing incidence scanning telescopes and an EUV spectrometer/deep survey instrument covering the spectral region 70-800 A. The measured imaging characteristics, the effective areas, and the details of spectral responses of the instruments are presented. Diagrams of the cross-sectional views of the scanning telescope and the deep-survey/spectrometer telescope are included.

  16. Inertial instrument system for aerial surveying

    USGS Publications Warehouse

    Brown, R.H.; Chapman, W.H.; Hanna, W.F.; Mongan, C.E.; Hursh, J.W.

    1985-01-01

    An inertial guidance system for aerial surveying has been developed under contract to the U.S. Geological Survey. This prototype system, known as the aerial profiling of terrain (APT) system, is designed to determine continuously the positions of points along an aircraft flight path, or the underlying terrain profile, to an accuracy of + or - 0.5 ft (15 cm) vertically and + or - 2 ft (61 cm) horizontally. The system 's objective thus is to accomplish, from a fixed-wing aircraft, what would traditionally be accomplished from ground-based topographic surveys combined with aerial photography and photogrammetry. The two-part strategy for measuring the terrain profile entails: (1) use of an inertial navigator for continuous determination of the three-coordinate position of the aircraft, and (2) use of an eye-safe pulsed laser profiler for continuous measurement of the vertical distance from aircraft to land surface, so that the desired terrain profile can then be directly computed. The APT system, installed in a DeHavilland Twin Otter aircraft, is typically flown at a speed of 115 mph (105 knots) at an altitude of 2,000 ft (610 m) above the terrain. Performance-evaluation flights have shown that the vertical and horizontal accuracy specifications are met. (USGS)

  17. Customizing Survey Instruments and Data Collection to Reach Hispanic/Latino Adults in Border Communities in Texas

    PubMed Central

    Pederson, Linda L.; Thorne, Stacy L.; Caraballo, Ralph S.; Evans, Brian; Athey, Leslie; McMichael, Joseph

    2010-01-01

    Objectives. We sought to modify an instrument and to use it to collect information on smoking knowledge, attitudes, beliefs, and behaviors among Hispanics/Latinos, and to adapt survey methods to obtain high participation levels. Methods. Promotoras (outreach workers) conducted face-to-face interviews with 1485 Hispanic adults (July 2007–April 2008). The project team used GeoFrame field enumeration methods to develop a sampling frame from households in randomly selected colonias (residential areas along the Texas–Mexico border that may lack some basic necessities (e.g. portable water), in El Paso, Texas. Results. The revised questionnaire included 36 unchanged items from the State Adult Tobacco Survey, 7 modified items, and 17 new items focusing on possible culturally specific quitting methods, secondhand smoke issues, and attitudes and knowledge about tobacco use that might be unique for Hispanic/Latino groups. The eligibility rate was 90.2%, and the conservative combined completed screener and interview response rate was 80.0%. Conclusions. Strategic, targeted, carefully designed methods and surveys can achieve high reach and response rates in hard-to-reach populations. Similar procedures could be used to obtain cooperation of groups who may not be accessible with traditional methods. PMID:20147687

  18. Instrumentation for detailed bridge-scour measurements

    USGS Publications Warehouse

    Landers, Mark N.; Mueller, David S.; Trent, Roy E.; ,

    1993-01-01

    A portable instrumentation system is being developed to obtain channel bathymetry during floods for detailed bridge-scour measurements. Portable scour measuring systems have four components: sounding instrument, horizontal positioning instrument, deployment mechanisms, and data storage device. The sounding instrument will be a digital fathometer. Horizontal position will be measured using a range-azimuth based hydrographic survey system. The deployment mechanism designed for this system is a remote-controlled boat using a small waterplane area, twin-hull design. An on-board computer and radio will monitor the vessel instrumentation, record measured data, and telemeter data to shore.

  19. First Results from the Dense Extragalactic GBT+ARGUS Survey (DEGAS): A Direct, Quantitative Test of the Role of Gas Density in Star Formation

    NASA Astrophysics Data System (ADS)

    Kepley, Amanda; Bigiel, Frank; Bolatto, Alberto; Church, Sarah; Cleary, Kieran; Frayer, David; Gallagher, Molly; Gundersen, Joshua; Harris, Andrew; Hughes, Annie; Jimenez-Donaire, Maria Jesus; Kessler, Sarah; Lee, Cheoljong; Leroy, Adam; Li, Jialu; Donovan Meyer, Jennifer; Rosolowsky, Erik; Sandstrom, Karin; Schinnener, Eva; Schruba, Andreas; Sieth, Matt; Usero, Antonio

    2018-01-01

    Gas density plays a central role in all modern theories of star formation. A key test of these theories involves quantifying the resolved gas density distribution and its relationship to star formation within a wide range of galactic environments. Until recently, this experiment has been difficult to perform owing to the faint nature of key molecular gas tracers like HCN and HCO+, but the superior sensitivity of modern millimeter instruments like ALMA and the IRAM 30m make these types of experiments feasible. In particular, the sensitivity and resolution provided by large aperture of the GBT combined with fast mapping speeds made possible by its new 16-pixel, 3mm focal plane array (Argus) make the GBT an almost-ideal instrument for this type of study. The Dense Extragalactic GBT+Argus Survey (DEGAS) will leverage these capabilities to perform the largest, resolved survey of molecular gas tracers in nearby galaxies, ultimately mapping a suite of four molecular gas tracers in the inner 2’ by 2’ of 36 nearby galaxies. When complete in 2020, DEGAS will be the largest resolved survey of dense molecular gas tracers in nearby galaxies. This talk will present early results from the first observations for this Green Bank Telescope large survey and highlight some exciting future possibilities for this survey.

  20. Development and use of an instrument to measure scientific inquiry and related factors

    NASA Astrophysics Data System (ADS)

    Dunbar, Terry Frank

    The use of the scientific inquiry method of teaching science was investigated in one district's elementary schools. The study generated data directly from Albuquerque Public Schools fourth- and fifth-grade teachers through a mail-out survey and through observation. Two forms of an inquiry evaluation research instrument (Elementary Science Inquiry Survey - ESIS) were created. The ESIS-A is a classroom observation tool. The ESIS-B is a survey questionnaire designed to collect information from teachers. The study was designed first to establish reliability and validity for both forms of the instrument. The study made use of multiple regression and exploratory factor analysis. Sources used to establish the instruments' reliability and validity included: (1) Input from an international panel (qualitative analysis of comments sent by raters and quantitative analysis of numerical ratings sent by raters); (2) Cronbach's alpha; (3) Results of factor analysis; (4) Survey respondents' comments (qualitative analysis); (5) Teacher observation data. Cronbach's alpha for the data set was .8955. Inquiry practices were reported to occur between twice per week and three times per week. Teachers' comments regarding inquiry were reported. The ESIS was used to collect inquiry self-report data and teacher background data. The teacher background data included teacher science knowledge and information about their standards awareness and implementation. The following teacher knowledge factors were positively correlated with inquiry use: semesters of college science, science workshops taken, conducted scientific research, and SIMSE (NSF institute) participation. The following standards awareness and implementation factors were positively correlated with inquiry use: familiarity with the National Science Education Standards, familiarity with New Mexico science standards, state or national standards as a curriculum selection factor, student interest as a curriculum selection factor, and "no

  1. Automated Chemical Warfare Respirator Quantitative Fit Test Instrument

    DTIC Science & Technology

    1985-04-01

    i requisite to assessment of the level of protection provided by the respirator. Quantitative measurement of the variability of fit of the face- plec ...ACQUISITION SYSTEM CORN OIL FILlE RESERVOIR -~ HEATER CONCENTRATIOA ZAONVU~C RB EAHG1FECO PHOTOMETER- STA RT CIL RESERVOIR BOTTGM TEMPERATURE SWITCH...30 .........-.-.-... % L4* . 3.3.4 HP 3497A Control and Data Acquisition Unit lI, "%a.infraoc" i.; a box with five slots for plug-in modules pll u; a

  2. INSTRUMENTATION AND AUTOMATION IN PLANTS OF THE CHEMICAL AND OIL INDUSTRY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pastonesi, G.

    1961-07-01

    In a comprehensive survey of recent developments in the field of instrumentation and automation in the chemical and petroleum industry, radioisotopes are mentioned with respect to measurements by means of nuclear radiation, especially gamma rays. Here practical and economical solutions for difficult measurement problems have been devised and are already applied to (a) level gaging, (b) density measurements, (c) observation of chemical reactions, and (d) measurement of wear of apparatus and of their corrosion. All these measurements can be used with electronic relays for automation and control. Radioisotopes are applied in the food industry for processing fruit juices, in themore » evaporation and concentration of milk, the manufacture of chocolate, etc., and for nondestructive testing of chemical machinery and instruments which are exposed to great siress due to high temperature and the corrosive nature of many chemical substances and reactions. By using x rays or gamma rays, the effects of these factors can be followed during chemical operations, and the nature of corrosive destruction can be determined qualitatively and quantitatively. (OID)« less

  3. Role Of Social Networks In Resilience Of Naval Recruits: A Quantitative Analysis

    DTIC Science & Technology

    2016-06-01

    comprises 1,297 total surveys from a total of eight divisions of recruits at two different time periods. Quantitative analyses using surveys and network... surveys from a total of eight divisions of recruits at two different time periods. Quantitative analyses using surveys and network data examine the effects...NETWORKS IN RESILIENCE OF NAVAL RECRUITS: A QUANTITATIVE ANALYSIS by Andrea M. Watling June 2016 Thesis Advisor: Edward H. Powley Co

  4. Considerations in the construction of an instrument to assess attitudes regarding critical illness gene variation research.

    PubMed

    Freeman, Bradley D; Kennedy, Carie R; Bolcic-Jankovic, Dragana; Eastman, Alexander; Iverson, Ellen; Shehane, Erica; Celious, Aaron; Barillas, Jennifer; Clarridge, Brian

    2012-02-01

    Clinical studies conducted in intensive care units are associated with logistical and ethical challenges. Diseases investigated are precipitous and life-threatening, care is highly technological, and patients are often incapacitated and decision-making is provided by surrogates. These investigations increasingly involve collection of genetic data. The manner in which the exigencies of critical illness impact attitudes regarding genetic data collection is unstudied. Given interest in understanding stakeholder preferences as a foundation for the ethical conduct of research, filling this knowledge gap is timely. The conduct of opinion research in the critical care arena is novel. This brief report describes the development of parallel patient/surrogate decision-maker quantitative survey instruments for use in this environment. Future research employing this instrument or a variant of it with diverse populations promises to inform research practices in critical illness gene variation research.

  5. Considerations in the Construction of an Instrument to Assess Attitudes Regarding Critical Illness Gene Variation Research

    PubMed Central

    Freeman, Bradley D.; Kennedy, Carie R.; Bolcic-Jankovic, Dragana; Eastman, Alexander; Iverson, Ellen; Shehane, Erica; Celious, Aaron; Barillas, Jennifer; Clarridge, Brian

    2012-01-01

    Clinical studies conducted in intensive care units are associated with logistical and ethical challenges. Diseases investigated are precipitous and life-threatening, care is highly technological, and patients are often incapacitated and decision-making is provided by surrogates. These investigations increasingly involve collection of genetic data. The manner in which the exigencies of critical illness impact attitudes regarding genetic data collection is unstudied. Given interest in understanding stakeholder preferences as a foundation for the ethical conduct of research, filling this knowledge gap is timely. The conduct of opinion research in the critical care arena is novel. This brief report describes the development of parallel patient/surrogate decision-maker quantitative survey instruments for use in this environment. Future research employing this instrument or a variant of it with diverse populations promises to inform research practices in critical illness gene variation research. PMID:22378135

  6. [Methodological design for the National Survey Violence Against Women in Mexico].

    PubMed

    Olaiz, Gustavo; Franco, Aurora; Palma, Oswaldo; Echarri, Carlos; Valdez, Rosario; Herrera, Cristina

    2006-01-01

    To describe the methodology, the research designs used, the estimation and sample selection, variable definitions, collection instruments, and operative design and analytical procedures for the National Survey Violence Against Women in Mexico. A complex (two-step) cross-sectional study was designed and the qualitative design was carried out using in-depth interviews and participant observation in health care units. We obtained for the quantitative study a total of 26 240 interviews in women users of health services and 2 636 questionnaires for health workers; the survey is representative of the 32 Mexican states. For the qualitative study 26 in-depth interviews were conducted with female users and 60 interviews with health workers in the States of Quintana Roo, Coahuila and the Federal District.

  7. Construct Validity of Science Motivation and Beliefs Instrument (SLA-MB): A Case study in Sumedang, Indonesia

    NASA Astrophysics Data System (ADS)

    Rachmatullah, A.; Octavianda, R. P.; Ha, M.; Rustaman, N. Y.; Diana, S.

    2017-02-01

    Along with numerous instruments developed and used in science education researches, some of those instruments have been translated to local language in the country where the instruments were used. Most of researchers that used those translated instruments did not report the quality of those translated instruments. One of the instruments is the Scientific Literacy Assessment (SLA) including the Science Motivation and Beliefs (SLA-MB) as part of the SLA. In this study, the SLA-MB has been translated into Indonesian Language (Bahasa). The purpose of this study is to investigate the SLA-MB instrument that has been translated to Indonesian language from the view of dimensionality, reliability, item quality and differential item functioning (DIF) based on IRT-Rasch analysis. We used Conquest and Winstep as the program for IRT-Rasch analysis. We employed quantitative research method with school-survey on this study. Research subjects are 223 Indonesian Middle school students (age 13-16), with 64 boys and 159 girls. IRT-Rasch analysis of the SLA-MB Indonesian version indicated that a three-dimensional model fit significantly better than one-dimension model, and the reliability of each dimensions are about 0.60 to 0.82. As well as those findings, fit values of all items are acceptable, moreover we found no DIF for all of the SLA-MB items. Overall, our study suggests that Indonesian version of SLA-MB is acceptable to be implemented as research instrument conducted in Indonesia.

  8. An instrument to measure job satisfaction of nursing home administrators

    PubMed Central

    Castle, Nicholas G

    2006-01-01

    Background The psychometric properties of the nursing home administrator job satisfaction questionnaire (NHA-JSQ) are presented, and the steps used to develop this instrument. Methods The NHA-JSQ subscales were developed from pilot survey activities with 93 administrators, content analysis, and a research panel. The resulting survey was sent to 1,000 nursing home administrators. Factor analyses were used to determine the psychometric properties of the instrument. Results Of the 1,000 surveys mailed, 721 usable surveys were returned (72 percent response rate). The factor analyses show that the items were representative of six underlying factors (i.e., coworkers, work demands, work content, work load, work skills, and rewards). Conclusion The NHA-JSQ represents a short, psychometrically sound job satisfaction instrument for use in nursing homes. PMID:17029644

  9. Economic instruments for obesity prevention: results of a scoping review and modified Delphi survey.

    PubMed

    Faulkner, Guy E J; Grootendorst, Paul; Nguyen, Van Hai; Andreyeva, Tatiana; Arbour-Nicitopoulos, Kelly; Auld, M Christopher; Cash, Sean B; Cawley, John; Donnelly, Peter; Drewnowski, Adam; Dubé, Laurette; Ferrence, Roberta; Janssen, Ian; Lafrance, Jeffrey; Lakdawalla, Darius; Mendelsen, Rena; Powell, Lisa M; Traill, W Bruce; Windmeijer, Frank

    2011-10-06

    Comprehensive, multi-level approaches are required to address obesity. One important target for intervention is the economic domain. The purpose of this study was to synthesize existing evidence regarding the impact of economic policies targeting obesity and its causal behaviours (diet, physical activity), and to make specific recommendations for the Canadian context. Arksey and O'Malley's (2005) methodological framework for conducting scoping reviews was adopted for this study and this consisted of two phases: 1) a structured literature search and review, and 2) consultation with experts in the research field through a Delphi survey and an in-person expert panel meeting in April 2010. Two key findings from the scoping review included 1) consistent evidence that weight outcomes are responsive to food and beverage prices. The debate on the use of food taxes and subsidies to address obesity should now shift to how best to address practical issues in designing such policies; and 2) very few studies have examined the impact of economic instruments to promote physical activity and clear policy recommendations cannot be made at this time. Delphi survey findings emphasised the relatively modest impact any specific economic instrument would have on obesity independently. Based on empirical evidence and expert opinion, three recommendations were supported. First, to create and implement an effective health filter to review new and current agricultural polices to reduce the possibility that such policies have a deleterious impact on population rates of obesity. Second, to implement a caloric sweetened beverage tax. Third, to examine how to implement fruit and vegetable subsidies targeted at children and low income households. In terms of economic interventions, shifting from empirical evidence to policy recommendation remains challenging. Overall, the evidence is not sufficiently strong to provide clear policy direction. Additionally, the nature of the experiments needed to

  10. The SAMI Galaxy Survey: instrument specification and target selection

    NASA Astrophysics Data System (ADS)

    Bryant, J. J.; Owers, M. S.; Robotham, A. S. G.; Croom, S. M.; Driver, S. P.; Drinkwater, M. J.; Lorente, N. P. F.; Cortese, L.; Scott, N.; Colless, M.; Schaefer, A.; Taylor, E. N.; Konstantopoulos, I. S.; Allen, J. T.; Baldry, I.; Barnes, L.; Bauer, A. E.; Bland-Hawthorn, J.; Bloom, J. V.; Brooks, A. M.; Brough, S.; Cecil, G.; Couch, W.; Croton, D.; Davies, R.; Ellis, S.; Fogarty, L. M. R.; Foster, C.; Glazebrook, K.; Goodwin, M.; Green, A.; Gunawardhana, M. L.; Hampton, E.; Ho, I.-T.; Hopkins, A. M.; Kewley, L.; Lawrence, J. S.; Leon-Saval, S. G.; Leslie, S.; McElroy, R.; Lewis, G.; Liske, J.; López-Sánchez, Á. R.; Mahajan, S.; Medling, A. M.; Metcalfe, N.; Meyer, M.; Mould, J.; Obreschkow, D.; O'Toole, S.; Pracy, M.; Richards, S. N.; Shanks, T.; Sharp, R.; Sweet, S. M.; Thomas, A. D.; Tonini, C.; Walcher, C. J.

    2015-03-01

    The SAMI Galaxy Survey will observe 3400 galaxies with the Sydney-AAO Multi-object Integral-field spectrograph (SAMI) on the Anglo-Australian Telescope in a 3-yr survey which began in 2013. We present the throughput of the SAMI system, the science basis and specifications for the target selection, the survey observation plan and the combined properties of the selected galaxies. The survey includes four volume-limited galaxy samples based on cuts in a proxy for stellar mass, along with low-stellar-mass dwarf galaxies all selected from the Galaxy And Mass Assembly (GAMA) survey. The GAMA regions were selected because of the vast array of ancillary data available, including ultraviolet through to radio bands. These fields are on the celestial equator at 9, 12 and 14.5 h, and cover a total of 144 deg2 (in GAMA-I). Higher density environments are also included with the addition of eight clusters. The clusters have spectroscopy from 2-degree Field Galaxy Redshift Survey (2dFGRS) and Sloan Digital Sky Survey (SDSS) and photometry in regions covered by the SDSS and/or VLT Survey Telescope/ATLAS. The aim is to cover a broad range in stellar mass and environment, and therefore the primary survey targets cover redshifts 0.004 < z < 0.095, magnitudes rpet < 19.4, stellar masses 107-1012 M⊙, and environments from isolated field galaxies through groups to clusters of ˜1015 M⊙.

  11. Educational needs of epileptologists regarding psychiatric comorbidities of the epilepsies: a descriptive quantitative survey.

    PubMed

    Mula, Marco; Cavalheiro, Esper; Guekht, Alla; Kanner, Andres M; Lee, Hyang Woon; Özkara, Çiğdem; Thomson, Alfredo; Wilson, Sarah J

    2017-06-01

    Psychiatric disorders are relatively frequent comorbidities in epilepsy and they have an impact on morbidity, mortality, and quality of life. This is a report from the Task Force on Education of the ILAE Commission on Neuropsychiatry based on a survey about educational needs of epileptologists regarding management of the psychiatric comorbidities of epilepsy. The Task Force designed a quantitative questionnaire to survey the self-perceived confidence of child and adult epileptologists and psychiatrists in managing major psychiatric comorbidities of epilepsy to identify: (1) critical areas of improvement from a list of skills that are usually considered necessary for effective management of these conditions, and (2) the preferred educational format for improving these skills. A total of 211 respondents from 36 different countries participated in the survey. Confidence and usefulness scores suggest that responders would most value education and training in the management of specific clinical scenarios. Child neurologists identified major Axis I disorders, such as mood and anxiety disorders, while adult neurologists identified attention deficit hyperactivity disorder, intellectual disabilities, and autistic spectrum disorder as key areas. Both adult and child neurologists identified screening skills as the priority. Psychiatrists mainly valued specific training in the management of psychiatric complications of epilepsy surgery or psychiatric adverse events of antiepileptic drugs. Sessions during congresses and face-to-face meetings represent the preferred educational format, while e-learning modules and review papers were chosen by a minority of respondents. Results of this survey identify key areas for improvement in managing the psychiatric comorbidities of epilepsy and suggest specific strategies to develop better training for clinicians involved in epilepsy care.

  12. The 4MOST instrument concept overview

    NASA Astrophysics Data System (ADS)

    Haynes, Roger; Barden, Samuel; de Jong, Roelof; Schnurr, Olivier; Bellido, Olga; Walcher, Jakob; Haynes, Dionne; Winkler, Roland; Bauer, Svend-Marian; Dionies, Frank; Saviauk, Allar; Chiappini, Cristina; Schwope, Axel; Brynnel, Joar; Steinmetz, Matthias; McMahon, Richard; Feltzing, Sofia; Francois, Patrick; Trager, Scott; Parry, Ian; Irwin, Mike; Walton, Nicholas; King, David; Sun, David; Gonzalez-Solares, Eduaro; Tosh, Ian; Dalton, Gavin; Middleton, Kevin; Bonifacio, Piercarlo; Jagourel, Pascal; Mignot, Shan; Cohen, Mathieu; Amans, Jean-Philippe; Royer, Frederic; Sartoretti, Paola; Pragt, Johan; Gerlofsma, Gerrit; Roelfsema, Ronald; Navarro, Ramon; Thimm, Guido; Seifert, Walter; Christlieb, Norbert; Mandel, Holger; Trifonov, Trifon; Xu, Wenli; Lang-Bardl, Florian; Muschielok, Bernard; Schlichter, Jörg; Hess, Hans-Joachim; Grupp, Frank; Boehringer, Hans; Boller, Thomas; Dwelly, Tom; Bender, Ralf; Rosati, Piero; Iwert, Olaf; Finger, Gert; Lizon L'Allemand, Jean-Louis; Saunders, Will; Sheinis, Andrew; Frost, Gabriella; Farrell, Tony; Waller, Lewis; Depagne, Eric; Laurent, Florence; Caillier, Patrick; Kosmalski, Johan; Richard, Johan; Bacon, Roland; Ansorge, Wolfgang

    2014-07-01

    The 4MOST[1] instrument is a concept for a wide-field, fibre-fed high multiplex spectroscopic instrument facility on the ESO VISTA telescope designed to perform a massive (initially >25x106 spectra in 5 years) combined all-sky public survey. The main science drivers are: Gaia follow up of chemo-dynamical structure of the Milky Way, stellar radial velocities, parameters and abundances, chemical tagging; eROSITA follow up of cosmology with x-ray clusters of galaxies, X-ray AGN/galaxy evolution to z~5, Galactic X-ray sources and resolving the Galactic edge; Euclid/LSST/SKA and other survey follow up of Dark Energy, Galaxy evolution and transients. The surveys will be undertaken simultaneously requiring: highly advanced targeting and scheduling software, also comprehensive data reduction and analysis tools to produce high-level data products. The instrument will allow simultaneous observations of ~1600 targets at R~5,000 from 390-900nm and ~800 targets at R<18,000 in three channels between ~395-675nm (channel bandwidth: 45nm blue, 57nm green and 69nm red) over a hexagonal field of view of ~ 4.1 degrees. The initial 5-year 4MOST survey is currently expect to start in 2020. We provide and overview of the 4MOST systems: optomechanical, control, data management and operations concepts; and initial performance estimates.

  13. Understanding nature's particle accelerators using high energy gamma-ray survey instruments

    NASA Astrophysics Data System (ADS)

    Abeysekara, Anushka Udara

    Nature's particle accelerators, such as Pulsars, Pulsar Wind Nebulae, Active Galactic Nuclei and Supernova Remnants accelerate charged particles to very high energies that then produce high energy photons. The particle acceleration mechanisms and the high energy photon emission mechanisms are poorly understood phenomena. These mechanisms can be understood either by studying individual sources in detail or, alternatively, using the collective properties of a sample of sources. Recent development of GeV survey instruments, such as Fermi-LAT, and TeV survey instruments, such as Milagro, provides a large sample of high energy gamma-ray flux measurements from galactic and extra-galactic sources. In this thesis I provide constraints on GeV and TeV radiation mechanisms using the X-ray-TeV correlations and GeV-TeV correlations. My data sample was obtained from three targeted searches for extragalactic sources and two targeted search for galactic sources, using the existing Milagro sky maps. The first extragalactic candidate list consists of Fermi-LAT GeV extragalactic sources, and the second extragalactic candidate list consists of TeVCat extragalactic sources that have been detected by Imaging Atmospheric Cerenkov Telescopes (IACTs). In both extragalactic candidate lists Markarian 421 was the only source detected by Milagro. A comparison between the Markarian 421 time-averaged flux, measured by Milagro, and the flux measurements of transient states, measured by IACTs, is discussed. The third extragalactic candidate list is a list of potential TeV emitting BL Lac candidates that was synthesized using X-ray observations of BL Lac objects and a Synchrotron Self-Compton model. Milagro's sensitivity was not sufficient to detect any of those candidates. However, the 95% confidence flux upper limits of those sources were above the predicted flux. Therefore, these results provide evidence to conclude that the Synchrotron Self-Compton model for BL Lac objects is still a viable

  14. Cardiovascular instrumentation for spaceflight

    NASA Technical Reports Server (NTRS)

    Schappell, R. T.; Polhemus, J. T.; Ganiaris, N. J.

    1976-01-01

    The observation mechanisms dealing with pressure, flow, morphology, temperature, etc. are discussed. The approach taken in the performance of this study was to (1) review ground and space-flight data on cardiovascular function, including earlier related ground-based and space-flight animal studies, Mercury, Gemini, Apollo, Skylab, and recent bed-rest studies, (2) review cardiovascular measurement parameters required to assess individual performance and physiological alternations during space flight, (3) perform an instrumentation survey including a literature search as well as personal contact with the applicable investigators, (4) assess instrumentation applicability with respect to the established criteria, and (5) recommend future research and development activity. It is concluded that, for the most part, the required instrumentation technology is available but that mission-peculiar criteria will require modifications to adapt the applicable instrumentation to a space-flight configuration.

  15. Instrumentation Needs of Academic Departments of Chemistry: A Survey Study. Report of a Joint Task Force of the Committee on Science and Committee on Chemistry and Public Affairs.

    ERIC Educational Resources Information Center

    American Chemical Society, Washington, DC.

    A questionnaire was mailed to 50 major chemistry departments, 112 smaller chemistry departments, and 25 chemical engineering (CE) departments. The survey (included in an appendix) consists of a series of questions on two broad subjects--the current inventory at the surveyed institutions and the needs for instrumentation. Responses were received…

  16. Instrumentation for Environmental Monitoring: Water, Volume 2.

    ERIC Educational Resources Information Center

    California Univ., Berkeley. Lawrence Berkeley Lab.

    This volume is one of a series discussing instrumentation for environmental monitoring. Each volume contains an overview of the basic problems, comparisons among the basic methods of sensing and detection, and notes that summarize the characteristics of presently available instruments and techniques. The text of this survey discusses the…

  17. 78 FR 64202 - Quantitative Messaging Research

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-28

    ... COMMODITY FUTURES TRADING COMMISSION Quantitative Messaging Research AGENCY: Commodity Futures... survey will follow qualitative message testing research (for which CFTC received fast- track OMB approval... comments. Please submit your comments using only one method and identify that it is for the ``Quantitative...

  18. Development of a Biological Science Quantitative Reasoning Exam (BioSQuaRE)

    ERIC Educational Resources Information Center

    Stanhope, Liz; Ziegler, Laura; Haque, Tabassum; Le, Laura; Vinces, Marcelo; Davis, Gregory K.; Zieffler, Andrew; Brodfuehrer, Peter; Preest, Marion; Belitsky, Jason M.; Umbanhowar, Charles, Jr.; Overvoorde, Paul J.

    2017-01-01

    Multiple reports highlight the increasingly quantitative nature of biological research and the need to innovate means to ensure that students acquire quantitative skills. We present a tool to support such innovation. The Biological Science Quantitative Reasoning Exam (BioSQuaRE) is an assessment instrument designed to measure the quantitative…

  19. Development of a survey instrument to measure connectivity to evaluate national public health preparedness and response performance.

    PubMed

    Dorn, Barry C; Savoia, Elena; Testa, Marcia A; Stoto, Michael A; Marcus, Leonard J

    2007-01-01

    Survey instruments for evaluating public health preparedness have focused on measuring the structure and capacity of local, state, and federal agencies, rather than linkages among structure, process, and outcomes. To focus evaluation on the latter, we evaluated the linkages among individuals, organizations, and systems using the construct of "connectivity" and developed a measurement instrument. Results from focus groups of emergency preparedness first responders generated 62 items used in the development sample of 187 respondents. Item reduction and factors analyses were conducted to confirm the scale's components. The 62 items were reduced to 28. Five scales explained 70% of the total variance (number of items, percent variance explained, Cronbach's alpha) including connectivity with the system (8, 45%, 0.94), coworkers (7, 7%, 0.91), organization (7, 12%, 0.93), and perceptions (6, 6%, 0.90). Discriminant validity was found to be consistent with the factor structure. We developed a Connectivity Measurement Tool for the public health workforce consisting of a 34-item questionnaire found to be a reliable measure of connectivity with preliminary evidence of construct validity.

  20. Quantitative analysis of residual protein contamination of podiatry instruments reprocessed through local and central decontamination units

    PubMed Central

    2011-01-01

    Background The cleaning stage of the instrument decontamination process has come under increased scrutiny due to the increasing complexity of surgical instruments and the adverse affects of residual protein contamination on surgical instruments. Instruments used in the podiatry field have a complex surface topography and are exposed to a wide range of biological contamination. Currently, podiatry instruments are reprocessed locally within surgeries while national strategies are favouring a move toward reprocessing in central facilities. The aim of this study was to determine the efficacy of local and central reprocessing on podiatry instruments by measuring residual protein contamination of instruments reprocessed by both methods. Methods The residual protein of 189 instruments reprocessed centrally and 189 instruments reprocessed locally was determined using a fluorescent assay based on the reaction of proteins with o-phthaldialdehyde/sodium 2-mercaptoethanesulfonate. Results Residual protein was detected on 72% (n = 136) of instruments reprocessed centrally and 90% (n = 170) of instruments reprocessed locally. Significantly less protein (p < 0.001) was recovered from instruments reprocessed centrally (median 20.62 μg, range 0 - 5705 μg) than local reprocessing (median 111.9 μg, range 0 - 6344 μg). Conclusions Overall, the results show the superiority of central reprocessing for complex podiatry instruments when protein contamination is considered, though no significant difference was found in residual protein between local decontamination unit and central decontamination unit processes for Blacks files. Further research is needed to undertake qualitative identification of protein contamination to identify any cross contamination risks and a standard for acceptable residual protein contamination applicable to different instruments and specialities should be considered as a matter of urgency. PMID:21219613

  1. Quantitative analysis of residual protein contamination of podiatry instruments reprocessed through local and central decontamination units.

    PubMed

    Smith, Gordon Wg; Goldie, Frank; Long, Steven; Lappin, David F; Ramage, Gordon; Smith, Andrew J

    2011-01-10

    The cleaning stage of the instrument decontamination process has come under increased scrutiny due to the increasing complexity of surgical instruments and the adverse affects of residual protein contamination on surgical instruments. Instruments used in the podiatry field have a complex surface topography and are exposed to a wide range of biological contamination. Currently, podiatry instruments are reprocessed locally within surgeries while national strategies are favouring a move toward reprocessing in central facilities. The aim of this study was to determine the efficacy of local and central reprocessing on podiatry instruments by measuring residual protein contamination of instruments reprocessed by both methods. The residual protein of 189 instruments reprocessed centrally and 189 instruments reprocessed locally was determined using a fluorescent assay based on the reaction of proteins with o-phthaldialdehyde/sodium 2-mercaptoethanesulfonate. Residual protein was detected on 72% (n = 136) of instruments reprocessed centrally and 90% (n = 170) of instruments reprocessed locally. Significantly less protein (p < 0.001) was recovered from instruments reprocessed centrally (median 20.62 μg, range 0 - 5705 μg) than local reprocessing (median 111.9 μg, range 0 - 6344 μg). Overall, the results show the superiority of central reprocessing for complex podiatry instruments when protein contamination is considered, though no significant difference was found in residual protein between local decontamination unit and central decontamination unit processes for Blacks files. Further research is needed to undertake qualitative identification of protein contamination to identify any cross contamination risks and a standard for acceptable residual protein contamination applicable to different instruments and specialities should be considered as a matter of urgency.

  2. Today's and Tomorrow's Instruments.

    PubMed

    Conty, Claude

    2001-03-01

    This article will discuss the importance of Raimond Castaing's thesis on the genesis of a nondestructive and truly quantitative microanalytical method that assisted the scientific community in moving forward in the development of microanalytical instruments. I will also share with you my recollection of the decades of improvement in the electron probe microanalyzer (EPMA), that has allowed us to reach our present level of instrument sophistication, and I will explore with you my thoughts on the future evolution of this technique. To conclude, I will present the current status of related microanalysis techniques developed under Castaing in Orsay in the 1960s, as Castaing's interest in microanalysis was not limited to electron probe microanalysis alone.

  3. Students' Attitudes toward and Conceptual Understanding of Chemical Instrumentation

    ERIC Educational Resources Information Center

    Miller, Larry S.; Nakhleh, Mary B.; Nash, John J.; Meyer, Jeanne A.

    2004-01-01

    Students' attitudes toward and conceptual understanding of chemical instrumentation is surveyed. The study shows that, in general, the students' attitudes toward using instrumentation in the lab is quite positive and they felt that using instrumentation in the lab allowed them not only to connect "chemistry" and the "real world", but also to…

  4. Development of an RDECOM Workforce Motivational Survey Instrument

    DTIC Science & Technology

    2016-09-01

    United States Army Research Development and Engineering Command ( RDECOM ) supervisory engineers, General Schedule (GS) 14 and 15, reviewed the survey...transition to the Human Resources directorate in RDECOM . Subsequently, we developed a plan to provide recommendations within the current government...for broad-level survey dissemination and performance of responses analyses by RDECOM to affect workforce policy change implementation. In conclusion

  5. High-throughput real-time quantitative reverse transcription PCR.

    PubMed

    Bookout, Angie L; Cummins, Carolyn L; Mangelsdorf, David J; Pesola, Jean M; Kramer, Martha F

    2006-02-01

    Extensive detail on the application of the real-time quantitative polymerase chain reaction (QPCR) for the analysis of gene expression is provided in this unit. The protocols are designed for high-throughput, 384-well-format instruments, such as the Applied Biosystems 7900HT, but may be modified to suit any real-time PCR instrument. QPCR primer and probe design and validation are discussed, and three relative quantitation methods are described: the standard curve method, the efficiency-corrected DeltaCt method, and the comparative cycle time, or DeltaDeltaCt method. In addition, a method is provided for absolute quantification of RNA in unknown samples. RNA standards are subjected to RT-PCR in the same manner as the experimental samples, thus accounting for the reaction efficiencies of both procedures. This protocol describes the production and quantitation of synthetic RNA molecules for real-time and non-real-time RT-PCR applications.

  6. Development of an Instrument for Measuring Clinicians’ Power Perceptions in the Workplace

    PubMed Central

    Bartos, Christa E.; Fridsma, Douglas B.; Butler, Brian S.; Penrod, Louis E.; Becich, Michael J.; Crowley, Rebecca S.

    2008-01-01

    We report on the development of an instrument to measure clinicians’ perceptions of their personal power in the workplace in relation to resistance to computerized physician order entry (CPOE). The instrument is based on French and Raven’s six bases of social power and uses a semantic differential methodology. A measurement study was conducted to determine the reliability and validity of the survey. The survey was administered online and distributed via a URL by email to 19 physicians, nurses, and health unit coordinators from a university hospital. Acceptable reliability was achieved by removing or moving some semantic differential word pairs used to represent the six power bases (alpha range from 0.76–0.89). The Semantic Differential Power Perception (SDPP) survey validity was tested against an already validated instrument and found to be acceptable (correlation range from 0.51–0.81). The SDPP survey instrument was determined to be both reliable and valid. PMID:18375189

  7. Television camera as a scientific instrument

    NASA Technical Reports Server (NTRS)

    Smokler, M. I.

    1970-01-01

    Rigorous calibration program, coupled with a sophisticated data-processing program that introduced compensation for system response to correct photometry, geometric linearity, and resolution, converted a television camera to a quantitative measuring instrument. The output data are in the forms of both numeric printout records and photographs.

  8. Instrumental-Music Study and Student Achievement

    ERIC Educational Resources Information Center

    Heninger, Benjamin Thomas

    2017-01-01

    This quantitative study explained relationships among independent variables that included instrumental music participation and achievement on a standardized test by participants in the ninth grade at a western Wisconsin high school. The ACT "Aspire" (2017) test is a vertically articulated, standards-based system of assessments. Subtest…

  9. Passive thermal infrared hyperspectral imaging for quantitative imaging of shale gas leaks

    NASA Astrophysics Data System (ADS)

    Gagnon, Marc-André; Tremblay, Pierre; Savary, Simon; Farley, Vincent; Guyot, Éric; Lagueux, Philippe; Morton, Vince; Giroux, Jean; Chamberland, Martin

    2017-10-01

    There are many types of natural gas fields including shale formations that are common especially in the St-Lawrence Valley (Canada). Since methane (CH4), the major component of shale gas, is odorless, colorless and highly flammable, in addition to being a greenhouse gas, methane emanations and/or leaks are important to consider for both safety and environmental reasons. Telops recently launched on the market the Hyper-Cam Methane, a field-deployable thermal infrared hyperspectral camera specially tuned for detecting methane infrared spectral features under ambient conditions and over large distances. In order to illustrate the benefits of this novel research instrument for natural gas imaging, the instrument was brought on a site where shale gas leaks unexpectedly happened during a geological survey near the Enfant-Jesus hospital in Quebec City, Canada, during December 2014. Quantitative methane imaging was carried out based on methane's unique infrared spectral signature. Optical flow analysis was also carried out on the data to estimate the methane mass flow rate. The results show how this novel technique could be used for advanced research on shale gases.

  10. A Qualitative-Quantitative H-NMR Experiment for the Instrumental Analysis Laboratory.

    ERIC Educational Resources Information Center

    Phillips, John S.; Leary, James J.

    1986-01-01

    Describes an experiment combining qualitative and quantitative information from hydrogen nuclear magnetic resonance spectra. Reviews theory, discusses the experimental approach, and provides sample results. (JM)

  11. Economic instruments for obesity prevention: results of a scoping review and modified delphi survey

    PubMed Central

    2011-01-01

    Background Comprehensive, multi-level approaches are required to address obesity. One important target for intervention is the economic domain. The purpose of this study was to synthesize existing evidence regarding the impact of economic policies targeting obesity and its causal behaviours (diet, physical activity), and to make specific recommendations for the Canadian context. Methods Arksey and O'Malley's (2005) methodological framework for conducting scoping reviews was adopted for this study and this consisted of two phases: 1) a structured literature search and review, and 2) consultation with experts in the research field through a Delphi survey and an in-person expert panel meeting in April 2010. Results Two key findings from the scoping review included 1) consistent evidence that weight outcomes are responsive to food and beverage prices. The debate on the use of food taxes and subsidies to address obesity should now shift to how best to address practical issues in designing such policies; and 2) very few studies have examined the impact of economic instruments to promote physical activity and clear policy recommendations cannot be made at this time. Delphi survey findings emphasised the relatively modest impact any specific economic instrument would have on obesity independently. Based on empirical evidence and expert opinion, three recommendations were supported. First, to create and implement an effective health filter to review new and current agricultural polices to reduce the possibility that such policies have a deleterious impact on population rates of obesity. Second, to implement a caloric sweetened beverage tax. Third, to examine how to implement fruit and vegetable subsidies targeted at children and low income households. Conclusions In terms of economic interventions, shifting from empirical evidence to policy recommendation remains challenging. Overall, the evidence is not sufficiently strong to provide clear policy direction. Additionally

  12. Achievement Goals, Learning Strategies and Instrumental Performance

    ERIC Educational Resources Information Center

    Nielsen, Siw Graabraek

    2008-01-01

    The current study is a survey of the achievement goals of music students and the manner in which their strategies and instrumental performance relate to these goals. In the context of advanced instrumental learning, the rationale for the present study was to contribute to the literature on motivation in music students, and thereby, help teachers…

  13. Exploring cosmic origins with CORE: The instrument

    NASA Astrophysics Data System (ADS)

    de Bernardis, P.; Ade, P. A. R.; Baselmans, J. J. A.; Battistelli, E. S.; Benoit, A.; Bersanelli, M.; Bideaud, A.; Calvo, M.; Casas, F. J.; Castellano, M. G.; Catalano, A.; Charles, I.; Colantoni, I.; Columbro, F.; Coppolecchia, A.; Crook, M.; D'Alessandro, G.; De Petris, M.; Delabrouille, J.; Doyle, S.; Franceschet, C.; Gomez, A.; Goupy, J.; Hanany, S.; Hills, M.; Lamagna, L.; Macias-Perez, J.; Maffei, B.; Martin, S.; Martinez-Gonzalez, E.; Masi, S.; McCarthy, D.; Mennella, A.; Monfardini, A.; Noviello, F.; Paiella, A.; Piacentini, F.; Piat, M.; Pisano, G.; Signorelli, G.; Tan, C. Y.; Tartari, A.; Trappe, N.; Triqueneaux, S.; Tucker, C.; Vermeulen, G.; Young, K.; Zannoni, M.; Achúcarro, A.; Allison, R.; Artall, E.; Ashdown, M.; Ballardini, M.; Banday, A. J.; Banerji, R.; Bartlett, J.; Bartolo, N.; Basak, S.; Bonaldi, A.; Bonato, M.; Borrill, J.; Bouchet, F.; Boulanger, F.; Brinckmann, T.; Bucher, M.; Burigana, C.; Buzzelli, A.; Cai, Z. Y.; Carvalho, C. S.; Challinor, A.; Chluba, J.; Clesse, S.; De Gasperis, G.; De Zotti, G.; Di Valentino, E.; Diego, J. M.; Errard, J.; Feeney, S.; Fernandez-Cobos, R.; Finelli, F.; Forastieri, F.; Galli, S.; Génova-Santos, R.; Gerbino, M.; González-Nuevo, J.; Hagstotz, S.; Greenslade, J.; Handley, W.; Hernández-Monteagudo, C.; Hervias-Caimapo, C.; Hivon, E.; Kiiveri, K.; Kisner, T.; Kitching, T.; Kunz, M.; Kurki-Suonio, H.; Lasenby, A.; Lattanzi, M.; Lesgourgues, J.; Lewis, A.; Liguori, M.; Lindholm, V.; Luzzi, G.; Martins, C. J. A. P.; Matarrese, S.; Melchiorri, A.; Melin, J. B.; Molinari, D.; Natoli, P.; Negrello, M.; Notari, A.; Paoletti, D.; Patanchon, G.; Polastri, L.; Polenta, G.; Pollo, A.; Poulin, V.; Quartin, M.; Remazeilles, M.; Roman, M.; Rubiño-Martín, J. A.; Salvati, L.; Tomasi, M.; Tramonte, D.; Trombetti, T.; Väliviita, J.; Van de Weyjgaert, R.; van Tent, B.; Vennin, V.; Vielva, P.; Vittorio, N.

    2018-04-01

    We describe a space-borne, multi-band, multi-beam polarimeter aiming at a precise and accurate measurement of the polarization of the Cosmic Microwave Background. The instrument is optimized to be compatible with the strict budget requirements of a medium-size space mission within the Cosmic Vision Programme of the European Space Agency. The instrument has no moving parts, and uses arrays of diffraction-limited Kinetic Inductance Detectors to cover the frequency range from 60 GHz to 600 GHz in 19 wide bands, in the focal plane of a 1.2 m aperture telescope cooled at 40 K, allowing for an accurate extraction of the CMB signal from polarized foreground emission. The projected CMB polarization survey sensitivity of this instrument, after foregrounds removal, is 1.7 μKṡarcmin. The design is robust enough to allow, if needed, a downscoped version of the instrument covering the 100 GHz to 600 GHz range with a 0.8 m aperture telescope cooled at 85 K, with a projected CMB polarization survey sensitivity of 3.2 μKṡarcmin.

  14. Instrumental Techniques in Archeological Research

    DTIC Science & Technology

    1988-09-01

    and instruments borrowed from the fields of chemistry , physics, geology, metallurgy, and ceramic engineering yield quantitative data on archeological...artifacts. Early analyses relied primarily on wet chemistry techniques in which samples of artifacts were dissolved into liquid solutions, destroying...other organic and inorganic materials. Advantages and disadvantages are dis- cussed. Each technique is presented with attention to appropriate materials

  15. [Job stress and well-being of care providers: development of a standardized survey instrument].

    PubMed

    Kivimäki, M; Lindström, K

    1992-01-01

    The main aim was to develop a standardized survey instrument for measuring job stress and well-being in hospital settings. The actual study group consisted of 349 workers from medical bed wards, first aid unit wards and bed wards for gynecology and obstetrics in a middle-sized hospital in the Helsinki region. Based on the factor analysis of separate questions, the following content areas were chosen for the job stressor scales: haste at work, problems in interpersonal relations at work, problems in occupational collaboration with others, too much responsibility, safety and health risks, lack of appreciation, troublesome patients, and lack of equipment and resources. Content areas for well-being scales and items were general job satisfaction, strain symptoms, perceived mental and physical work load. The reference values of the questionnaire and reliabilities for the scales were calculated. The application and further development of the questionnaire was discussed.

  16. Analysis of Hand Size and Ergonomics of Instruments in Pediatric Minimally Invasive Surgery.

    PubMed

    Filisetti, Claudia; Cho, Alexander; Riccipetitoni, Giovanna; Saxena, Amulya K

    2015-10-01

    Moving from the study conducted in 2004 on adult surgeons we want to analyze the ergonomics applied in pediatric minimally invasive surgery. An online survey was conducted among the members of the European Paediatric Surgeons' Association that included 14 questions pertaining to demographic, surgical glove size, double glove use, prior hand surgery, and the ease or difficulty in using different types of laparoscopic instruments. A total of 138 pediatric surgeons completed the survey. The difficulty score (DS) was similar between the 3.5- and 5-mm instruments. Other specialized instruments such as Ligasure, Ultracision, Clip applicators, endobags, and staplers were found to have higher DS. The needle holder was the only instrument that is part of the normal 5-mm operating sets, which was found to have a higher DS. Our survey found increased DS with the endobag and stapler, but this was not significant. Also prior hand surgery or double glove use was not associated with difficulty in usage of minimally invasive instruments when compared with normal hands in this survey.

  17. Quantitative Hydrocarbon Surface Analysis

    NASA Technical Reports Server (NTRS)

    Douglas, Vonnie M.

    2000-01-01

    The elimination of ozone depleting substances, such as carbon tetrachloride, has resulted in the use of new analytical techniques for cleanliness verification and contamination sampling. The last remaining application at Rocketdyne which required a replacement technique was the quantitative analysis of hydrocarbons by infrared spectrometry. This application, which previously utilized carbon tetrachloride, was successfully modified using the SOC-400, a compact portable FTIR manufactured by Surface Optics Corporation. This instrument can quantitatively measure and identify hydrocarbons from solvent flush of hardware as well as directly analyze the surface of metallic components without the use of ozone depleting chemicals. Several sampling accessories are utilized to perform analysis for various applications.

  18. Public surveys at ESO

    NASA Astrophysics Data System (ADS)

    Arnaboldi, Magda; Delmotte, Nausicaa; Hilker, Michael; Hussain, Gaitee; Mascetti, Laura; Micol, Alberto; Petr-Gotzens, Monika; Rejkuba, Marina; Retzlaff, Jörg; Mieske, Steffen; Szeifert, Thomas; Ivison, Rob; Leibundgut, Bruno; Romaniello, Martino

    2016-07-01

    ESO has a strong mandate to survey the Southern Sky. In this article, we describe the ESO telescopes and instruments that are currently used for ESO Public Surveys, and the future plans of the community with the new wide-field-spectroscopic instruments. We summarize the ESO policies governing the management of these projects on behalf of the community. The on-going ESO Public Surveys and their science goals, their status of completion, and the new projects selected during the second ESO VISTA call in 2015/2016 are discussed. We then present the impact of these projects in terms of current numbers of refereed publications and the scientific data products published through the ESO Science Archive Facility by the survey teams, including the independent access and scientific use of the published survey data products by the astronomical community.

  19. A 20-Year Survey of Scientific Literacy and Attitudes Toward Science_An Overview

    NASA Astrophysics Data System (ADS)

    Impey, Chris David; Antonellis, J.; Johnson, E.; King, C.; CATS

    2009-01-01

    This poster presents the results of a long-term investigation into the science literacy and attitudes toward science of University of Arizona non-science major undergraduates. The survey instrument utilized in this study was derived from measures of adults’ science literacy, as defined and assessed by the National Science Foundation in its biannual Science and Engineering Indicators reports to the National Science Board. In addition, the survey instrument measures attitudes toward science and technology and toward pseudoscience. Quantitative data from over 9000 questionnaires have been into a database, and qualitative data from four open-ended questions has been coded thematically (see Antonellis et al., this meeting). The data will be used to address a number of research questions in the area of science education and science policy, including (1) how the level of science literacy of undergraduates compares to the adult population; (2) how science literacy and attitudes towards science have changed since 1987; (3) the relationship between science knowledge and attitudes towards science; and (4) the extent to which General Education science requirements at a large State university affect science knowledge and attitudes. The data will also be used to critically examine the concept of science literacy. The results of this study are being used by CATS to develop a survey instrument designed specifically for use with Astro 101 students to diagnose the effect our instruction has on their scientific attitudes and beliefs. We acknowledge the NSF for funding under Award No. 0715517, a CCLI Phase III Grant for the Collaboration of Astronomy Teaching Scholars (CATS).

  20. Why Open-Ended Survey Questions Are Unlikely to Support Rigorous Qualitative Insights.

    PubMed

    LaDonna, Kori A; Taylor, Taryn; Lingard, Lorelei

    2018-03-01

    Health professions education researchers are increasingly relying on a combination of quantitative and qualitative research methods to explore complex questions in the field. This important and necessary development, however, creates new methodological challenges that can affect both the rigor of the research process and the quality of the findings. One example is "qualitatively" analyzing free-text responses to survey or assessment instrument questions. In this Invited Commentary, the authors explain why analysis of such responses rarely meets the bar for rigorous qualitative research. While the authors do not discount the potential for free-text responses to enhance quantitative findings or to inspire new research questions, they caution that these responses rarely produce data rich enough to generate robust, stand-alone insights. The authors consider exemplars from health professions education research and propose strategies for treating free-text responses appropriately.

  1. Survey of Aircraft Emissions and Related Instrumentation

    DOT National Transportation Integrated Search

    1971-03-31

    The report presents the preliminary results of a survey of transportation systems emissions monitoring requirements. Emissions of carbon monoxide, hydrocarbons, oxides of nitrogen and particulates from aircraft power plants, with emphasis on gas turb...

  2. Swift Burst Alert Telescope (BAT) Instrument Response

    NASA Technical Reports Server (NTRS)

    Parsons, A.; Hullinger, D.; Markwardt, C.; Barthelmy, S.; Cummings, J.; Gehrels, N.; Krimm, H.; Tueller, J.; Fenimore, E.; Palmer, D.

    2004-01-01

    The Burst Alert Telescope (BAT), a large coded aperture instrument with a wide field-of-view (FOV), provides the gamma-ray burst triggers and locations for the Swift Gamma-Ray Burst Explorer. In addition to providing this imaging information, BAT will perform a 15 keV - 150 keV all-sky hard x-ray survey based on the serendipitous pointings resulting from the study of gamma-ray bursts and will also monitor the sky for transient hard x-ray sources. For BAT to provide spectral and photometric information for the gamma-ray bursts, the transient sources and the all-sky survey, the BAT instrument response must be determined to an increasingly greater accuracy. In this talk, we describe the BAT instrument response as determined to an accuracy suitable for gamma-ray burst studies. We will also discuss the public data analysis tools developed to calculate the BAT response to sources at different energies and locations in the FOV. The level of accuracy required for the BAT instrument response used for the hard x-ray survey is significantly higher because this response must be used in the iterative clean algorithm for finding fainter sources. Because the bright sources add a lot of coding noise to the BAT sky image, fainter sources can be seen only after the counts due to the bright sources are removed. The better we know the BAT response, the lower the noise in the cleaned spectrum and thus the more sensitive the survey. Since the BAT detector plane consists of 32768 individual, 4 mm square CZT gamma-ray detectors, the most accurate BAT response would include 32768 individual detector response functions to separate mask modulation effects from differences in detector efficiencies! We describe OUT continuing work to improve the accuracy of the BAT instrument response and will present the current results of Monte Carlo simulations as well as BAT ground calibration data.

  3. Quality of reporting of surveys in critical care journals: a methodologic review.

    PubMed

    Duffett, Mark; Burns, Karen E; Adhikari, Neill K; Arnold, Donald M; Lauzier, François; Kho, Michelle E; Meade, Maureen O; Hayani, Omar; Koo, Karen; Choong, Karen; Lamontagne, François; Zhou, Qi; Cook, Deborah J

    2012-02-01

    Adequate reporting is needed to judge methodologic quality and assess the risk of bias of surveys. The objective of this study is to describe the methodology and quality of reporting of surveys published in five critical care journals. All issues (1996-2009) of the American Journal of Respiratory and Critical Care Medicine, Critical Care, Critical Care Medicine, Intensive Care Medicine, and Pediatric Critical Care Medicine. Two reviewers hand-searched all issues in duplicate. We included publications of self-administered questionnaires of health professionals and excluded surveys that were part of a multi-method study or measured the effect of an intervention. Data were abstracted in duplicate. We included 151 surveys. The frequency of survey publication increased at an average rate of 0.38 surveys per 1000 citations per year from 1996-2009 (p for trend = 0.001). The median number of respondents and reported response rates were 217 (interquartile range 90 to 402) and 63.3% (interquartile range 45.0% to 81.0%), respectively. Surveys originated predominantly from North America (United States [40.4%] and Canada [18.5%]). Surveys most frequently examined stated practice (78.8%), attitudes or opinions (60.3%), and less frequently knowledge (9.9%). The frequency of reporting on the survey design and methods were: 1) instrument development: domains (59.1%), item generation (33.1%), item reduction (12.6%); 2) instrument testing: pretesting or pilot testing (36.2%) and assessments of clarity (25.2%) or clinical sensibility (15.7%); and 3) clinimetric properties: qualitative or quantitative description of at least one of face, content, construct validity, intra- or inter-rater reliability, or consistency (28.5%). The reporting of five key elements of survey design and conduct did not significantly change over time. Surveys, primarily conducted in North America and focused on self-reported practice, are increasingly published in highly cited critical care journals. More

  4. Tandem transmission/reflection mode XRD instrument including XRF for in situ measurement of Martian rocks and soils

    NASA Astrophysics Data System (ADS)

    Delhez, Robert; Van der Gaast, S. J.; Wielders, Arno; de Boer, J. L.; Helmholdt, R. B.; van Mechelen, J.; Reiss, C.; Woning, L.; Schenk, H.

    2003-02-01

    The mineralogy of the surface material of Mars is the key to disclose its present and past life and climates. Clay mineral species, carbonates, and ice (water and CO2) are and/or contain their witnesses. X-ray powder diffraction (XRPD) is the most powerful analytical method to identify and quantitatively characterize minerals in complex mixtures. This paper discusses the development of a working model of an instrument consisting of a reflection mode diffractometer and a transmission mode CCD-XRPD instrument, combined with an XRF module. The CCD-XRD/XRF instrument is analogous to the instrument for Mars missions developed by Sarrazin et al. (1998). This part of the tandem instrument enables "quick and dirty" analysis of powdered (!) matter to monitor semi-quantitatively the presence of clay minerals as a group, carbonates, and ices and yields semi-quantitative chemical information from X-ray fluorescence (XRF). The reflection mode instrument (i) enables in-situ measurements of rocks and soils and quantitative information on the compounds identified, (ii) has a high resolution and reveals large spacings for accurate identification, in particular of clay mineral species, and (iii) the shape of the line profiles observed reveals the kind and approximate amounts of lattice imperfections present. It will be shown that the information obtained with the reflection mode diffractometer is crucial for finding signs of life and changes in the climate on Mars. Obviously this instrument can also be used for other extra-terrestrial research.

  5. Surveys and questionnaires in nursing research.

    PubMed

    Timmins, Fiona

    2015-06-17

    Surveys and questionnaires are often used in nursing research to elicit the views of large groups of people to develop the nursing knowledge base. This article provides an overview of survey and questionnaire use in nursing research, clarifies the place of the questionnaire as a data collection tool in quantitative research design and provides information and advice about best practice in the development of quantitative surveys and questionnaires.

  6. Status of ART-XC/SRG instrument

    NASA Astrophysics Data System (ADS)

    Pavlinsky, M.; Akimov, V.; Levin, V.; Krivchenko, A.; Rotin, A.; Kuznetsova, M.; Lapshov, I.; Tkachenko, A.; Semena, N.; Buntov, M.; Glushenko, A.; Arefiev, V.; Yaskovich, A.; Grebenev, S.; Sazonov, S.; Revnivtsev, M.; Lutovinov, A.; Molkov, S.; Krivonos, R.; Serbinov, D.; Kudelin, M.; Drozdova, T.; Voronkov, S.; Sunyaev, R.; Churazov, E.; Gilfanov, M.; Babyshkin, V.; Lomakin, I.; Menderov, A.; Gubarev, M.; Ramsey, B.; Kilaru, K.; O'Dell, S. L.; Kolodziejczak, J.; Elsner, R.; Zavlin, V.; Swartz, D.

    2016-07-01

    Spectrum Roentgen Gamma (SRG) is an X-ray astrophysical observatory, developed by Russia in collaboration with Germany. The mission will be launched in 2017 from Baikonur and placed in a 6-month-period halo orbit around L2. The scientific payload consists of two independent telescope arrays - a soft-x-ray survey instrument, eROSITA, being provided by Germany and a medium-x-ray-energy survey instrument ART-XC being developed by Russia. ART-XC will consist of seven independent, but co-aligned, telescope modules. The ART-XC flight mirror modules have been developed and fabricated at the NASA Marshall Space Flight Center (MSFC). Each mirror module will be aligned with a focal plane CdTe double-sided strip detector which will operate over the energy range of 6-30 keV, with an angular resolution of <1', a field of view of 34' and an expected energy resolution of about 12% at 14 keV. The current status of the ART-XC/SRG instrument is presented here.

  7. The Development of a Small-Scale Survey Instrument of UK Teachers to Study Professional Use (and Non-Use) of and Attitudes to Social Media

    ERIC Educational Resources Information Center

    Owen, Nathaniel; Fox, Alison; Bird, Terese

    2016-01-01

    This paper documents the creation, implementation and analysis of a survey instrument designed to reveal patterns of use and attitudes towards the value of social media by UK teachers. The study was motivated to discover which teachers use social media professionally, how they use it (both personally and professionally) and attitudes to social…

  8. The Conceptual Framework for the Development of a Mathematics Performance Assessment Instrument.

    ERIC Educational Resources Information Center

    Lane, Suzanne

    1993-01-01

    A conceptual framework is presented for the development of the Quantitative Understanding: Amplifying Student Achievement and Reasoning (QUASAR) Cognitive Assessment Instrument (QCAI) that focuses on the ability of middle-school students to problem solve, reason, and communicate mathematically. The instrument will provide programatic rather than…

  9. New journal selection for quantitative survey of infectious disease research: application for Asian trend analysis

    PubMed Central

    2009-01-01

    Background Quantitative survey of research articles, as an application of bibliometrics, is an effective tool for grasping overall trends in various medical research fields. This type of survey has been also applied to infectious disease research; however, previous studies were insufficient as they underestimated articles published in non-English or regional journals. Methods Using a combination of Scopus™ and PubMed, the databases of scientific literature, and English and non-English keywords directly linked to infectious disease control, we identified international and regional infectious disease journals. In order to ascertain whether the newly selected journals were appropriate to survey a wide range of research articles, we compared the number of original articles and reviews registered in the selected journals to those in the 'Infectious Disease Category' of the Science Citation Index Expanded™ (SCI Infectious Disease Category) during 1998-2006. Subsequently, we applied the newly selected journals to survey the number of original articles and reviews originating from 11 Asian countries during the same period. Results One hundred journals, written in English or 7 non-English languages, were newly selected as infectious disease journals. The journals published 14,156 original articles and reviews of Asian origin and 118,158 throughout the world, more than those registered in the SCI Infectious Disease Category (4,621 of Asian origin and 66,518 of the world in the category). In Asian trend analysis of the 100 journals, Japan had the highest percentage of original articles and reviews in the area, and no noticeable increase in articles was revealed during the study period. China, India and Taiwan had relatively large numbers and a high increase rate of original articles among Asian countries. When adjusting the publication of original articles according to the country population and the gross domestic product (GDP), Singapore and Taiwan were the most

  10. New journal selection for quantitative survey of infectious disease research: application for Asian trend analysis.

    PubMed

    Takahashi-Omoe, Hiromi; Omoe, Katsuhiko; Okabe, Nobuhiko

    2009-10-06

    Quantitative survey of research articles, as an application of bibliometrics, is an effective tool for grasping overall trends in various medical research fields. This type of survey has been also applied to infectious disease research; however, previous studies were insufficient as they underestimated articles published in non-English or regional journals. Using a combination of Scopus and PubMed, the databases of scientific literature, and English and non-English keywords directly linked to infectious disease control, we identified international and regional infectious disease journals. In order to ascertain whether the newly selected journals were appropriate to survey a wide range of research articles, we compared the number of original articles and reviews registered in the selected journals to those in the 'Infectious Disease Category' of the Science Citation Index Expanded (SCI Infectious Disease Category) during 1998-2006. Subsequently, we applied the newly selected journals to survey the number of original articles and reviews originating from 11 Asian countries during the same period. One hundred journals, written in English or 7 non-English languages, were newly selected as infectious disease journals. The journals published 14,156 original articles and reviews of Asian origin and 118,158 throughout the world, more than those registered in the SCI Infectious Disease Category (4,621 of Asian origin and 66,518 of the world in the category). In Asian trend analysis of the 100 journals, Japan had the highest percentage of original articles and reviews in the area, and no noticeable increase in articles was revealed during the study period. China, India and Taiwan had relatively large numbers and a high increase rate of original articles among Asian countries. When adjusting the publication of original articles according to the country population and the gross domestic product (GDP), Singapore and Taiwan were the most productive. A survey of 100 selected

  11. [Perception, translation and current use of English terms on the part of Italian non-physician healthcare personnel: a qualitative and quantitative survey].

    PubMed

    Conti, Andrea A

    2008-11-01

    The study of the use of English for medicine has become a continual source of enquiry. Aim of this survey was the systematic evaluation of the qualitative and quantitative perception, translation and current use of English terms on the part of Italian health operators. Eight English terms directly connected with the health scenario or related to it compliance", "imaging", "likelihood", "odds ratio", "outcome", "stent", "test", "trial") were selected and, by means of a paper registration form, they were administered to forty Italian health professionals (non-physicians), already active in the health sector and attending specialised health degree courses. The participants were asked to furnish up to two translational proposals for every single English term, and, after the written registration, there followed a structured oral discussion of the translation, perception and everyday use of the English terms in the working reality of the participants. This survey provides a scientific "real world" experience, and its qualitative and quantitative findings are of use in evaluating the level of correction in the adoption of English language on the part of health operators.

  12. Exploring information technology adoption by family physicians: survey instrument valuation.

    PubMed Central

    Dixon, D. R.; Stewart, M.

    2000-01-01

    As the information needs of family physicians become more complex, there will be a greater need to successfully implement the technologies needed to manage that information. The ability to stratify primary care physicians can enable the implementation process to be more efficient. This research tested a new instrument on 101 family physicians, and was able to stratify physicians into high, intermediate, and low information technology (IT) usage groups. It is expected that this stratification would allow managers of IT implementation to target specific adoption strategies for each group. The instrument is available from ddixon@julian.uwo.ca. PMID:11079870

  13. Using Texas Instruments Emulators as Teaching Tools in Quantitative Chemical Analysis

    ERIC Educational Resources Information Center

    Young, Vaneica Y.

    2011-01-01

    This technology report alerts upper-division undergraduate chemistry faculty and lecturers to the use of Texas Instruments emulators as virtual graphing calculators. These may be used in multimedia lectures to instruct students on the use of their graphing calculators to obtain solutions to complex chemical problems. (Contains 1 figure.)

  14. Assessment of Customer Service in Academic Health Care Libraries (ACSAHL): an instrument for measuring customer service*†

    PubMed Central

    Crossno, Jon E.; Berkins, Brenda; Gotcher, Nancy; Hill, Judith L.; McConoughey, Michelle; Walters, Mitchel

    2001-01-01

    Objectives: In a pilot study, the library had good results using SERVQUAL, a respected and often-used instrument for measuring customer satisfaction. The SERVQUAL instrument itself, however, received some serious and well-founded criticism from the respondents to our survey. The purpose of this study was to test the comparability of the results of SERVQUAL with a revised and shortened instrument modeled on SERVQUAL. The revised instrument, the Assessment of Customer Service in Academic Health Care Libraries (ACSAHL), was designed to better assess customer service in academic health care libraries. Methods: Surveys were sent to clients who had used the document delivery services at three academic medical libraries in Texas over the previous twelve to eighteen months. ACSAHL surveys were sent exclusively to clients at University of Texas (UT) Southwestern, while the client pools at the two other institutions were randomly divided and provided either SERVQUAL or ACSAHL surveys. Results: Results indicated that more respondents preferred the shorter ACSAHL instrument to the longer and more complex SERVQUAL instrument. Also, comparing the scores from both surveys indicated that ACSAHL elicited comparable results. Conclusions: ACSAHL appears to measure the same type of data in similar settings, but additional testing is recommended both to confirm the survey's results through data replication and to investigate whether the instrument applies to different service areas. PMID:11337948

  15. Comparison of two quantitative fit-test methods using N95 filtering facepiece respirators.

    PubMed

    Sietsema, Margaret; Brosseau, Lisa M

    2016-08-01

    Current regulations require annual fit testing before an employee can wear a respirator during work activities. The goal of this research is to determine whether respirator fit measured with two TSI Portacount instruments simultaneously sampling ambient particle concentrations inside and outside of the respirator facepiece is similar to fit measured during an ambient aerosol condensation nuclei counter quantitative fit test. Sixteen subjects (ten female; six male) were recruited for a range of facial sizes. Each subject donned an N95 filtering facepiece respirator, completed two fit tests in random order (ambient aerosol condensation nuclei counter quantitative fit test and two-instrument real-time fit test) without removing or adjusting the respirator between tests. Fit tests were compared using Spearman's rank correlation coefficients. The real-time two-instrument method fit factors were similar to those measured with the single-instrument quantitative fit test. The first four exercises were highly correlated (r > 0.7) between the two protocols. Respirator fit was altered during the talking or grimace exercise, both of which involve facial movements that could dislodge the facepiece. Our analyses suggest that the new real-time two-instrument methodology can be used in future studies to evaluate fit before and during work activities.

  16. Cross-cultural validation of instruments measuring health beliefs about colorectal cancer screening among Korean Americans.

    PubMed

    Lee, Shin-Young; Lee, Eunice E

    2015-02-01

    The purpose of this study was to report the instrument modification and validation processes to make existing health belief model scales culturally appropriate for Korean Americans (KAs) regarding colorectal cancer (CRC) screening utilization. Instrument translation, individual interviews using cognitive interviewing, and expert reviews were conducted during the instrument modification phase, and a pilot test and a cross-sectional survey were conducted during the instrument validation phase. Data analyses of the cross-sectional survey included internal consistency and construct validity using exploratory and confirmatory factor analysis. The main issues identified during the instrument modification phase were (a) cultural and linguistic translation issues and (b) newly developed items reflecting Korean cultural barriers. Cross-sectional survey analyses during the instrument validation phase revealed that all scales demonstrate good internal consistency reliability (Cronbach's alpha=.72~.88). Exploratory factor analysis showed that susceptibility and severity loaded on the same factor, which may indicate a threat variable. Items with low factor loadings in the confirmatory factor analysis may relate to (a) lack of knowledge about fecal occult blood testing and (b) multiple dimensions of the subscales. Methodological, sequential processes of instrument modification and validation, including translation, individual interviews, expert reviews, pilot testing and a cross-sectional survey, were provided in this study. The findings indicate that existing instruments need to be examined for CRC screening research involving KAs.

  17. Characterization of HPGe gamma spectrometric detectors systems for Instrumental Neutron Activation Analysis (INAA) at the Colombian Geological Survey

    NASA Astrophysics Data System (ADS)

    Sierra, O.; Parrado, G.; Cañón, Y.; Porras, A.; Alonso, D.; Herrera, D. C.; Peña, M.; Orozco, J.

    2016-07-01

    This paper presents the progress made by the Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey (SGC in its Spanish acronym), towards the characterization of its gamma spectrometric systems for Instrumental Neutron Activation Analysis (INAA), with the aim of introducing corrections to the measurements by variations in sample geometry. Characterization includes the empirical determination of the interaction point of gamma radiation inside the Germanium crystal, through the application of a linear model and the use of a fast Monte Carlo N-Particle (MCNP) software to estimate correction factors for differences in counting efficiency that arise from variations in sample density between samples and standards.

  18. Characterization of HPGe gamma spectrometric detectors systems for Instrumental Neutron Activation Analysis (INAA) at the Colombian Geological Survey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sierra, O., E-mail: osierra@sgc.gov.co; Parrado, G., E-mail: gparrado@sgc.gov.co; Cañón, Y.

    This paper presents the progress made by the Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey (SGC in its Spanish acronym), towards the characterization of its gamma spectrometric systems for Instrumental Neutron Activation Analysis (INAA), with the aim of introducing corrections to the measurements by variations in sample geometry. Characterization includes the empirical determination of the interaction point of gamma radiation inside the Germanium crystal, through the application of a linear model and the use of a fast Monte Carlo N-Particle (MCNP) software to estimate correction factors for differences in counting efficiency that arise from variations in samplemore » density between samples and standards.« less

  19. 78 FR 44164 - Notice of Intent To Seek Approval To Establish an Information Collection

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-23

    ..., and published literature; qualitative and quantitative analyses of surveys and interviews with.... This information collection request will include a survey instrument for principal investigators of past and current AISL projects, a survey instrument for project evaluators, and protocols for follow-up...

  20. Tomographic intensity mapping versus galaxy surveys: observing the Universe in H α emission with new generation instruments

    NASA Astrophysics Data System (ADS)

    Silva, B. Marta; Zaroubi, Saleem; Kooistra, Robin; Cooray, Asantha

    2018-04-01

    The H α line emission is an important probe for a number of fundamental quantities in galaxies, including their number density, star formation rate (SFR), and overall gas content. A new generation of low-resolution intensity mapping (IM) probes, e.g. SPHEREx and CDIM, will observe galaxies in H α emission over a large fraction of the sky from the local Universe till a redshift of z ˜ 6 - 10, respectively. This will also be the target line for observations by the high-resolution Euclid and WFIRST instruments in the z ˜ 0.7-2 redshift range. In this paper, we estimate the intensity and power spectra of the H α line in the z ˜ 0-5 redshift range using observed line luminosity functions (LFs), when possible, and simulations, otherwise. We estimate the significance of our predictions by accounting for the modelling uncertainties (e.g. SFR, extinction, etc.) and observational contamination. We find that IM surveys can make a statistical detection of the full H α emission between z ˜ 0.8 and 5. Moreover, we find that the high-frequency resolution and the sensitivity of the planned CDIM surveys allow for the separation of H α emission from several interloping lines. We explore ways to use the combination of these line intensities to probe galaxy properties. As expected, our study indicates that galaxy surveys will only detect bright galaxies that contribute up to a few per cent of the overall H α intensity. However, these surveys will provide important constraints on the high end of the H α LF and put strong constraints on the active galactic nucleus LF.

  1. Quantitative Analysis of Transnasal Anterior Skull Base Approach: Report of Technology for Intraoperative Assessment of Instrument Motion.

    PubMed

    Berens, Angelique M; Harbison, Richard Alex; Li, Yangming; Bly, Randall A; Aghdasi, Nava; Ferreira, Manuel; Hannaford, Blake; Moe, Kris S

    2017-08-01

    To develop a method to measure intraoperative surgical instrument motion. This model will be applicable to the study of surgical instrument kinematics including surgical training, skill verification, and the development of surgical warning systems that detect aberrant instrument motion that may result in patient injury. We developed an algorithm to automate derivation of surgical instrument kinematics in an endoscopic endonasal skull base surgery model. Surgical instrument motion was recorded during a cadaveric endoscopic transnasal approach to the pituitary using a navigation system modified to record intraoperative time-stamped Euclidian coordinates and Euler angles. Microdebrider tip coordinates and angles were referenced to the cadaver's preoperative computed tomography scan allowing us to assess surgical instrument kinematics over time. A representative cadaveric endoscopic endonasal approach to the pituitary was performed to demonstrate feasibility of our algorithm for deriving surgical instrument kinematics. Technical feasibility of automatically measuring intraoperative surgical instrument motion and deriving kinematics measurements was demonstrated using standard navigation equipment.

  2. Evaluation of Instructional Materials for Exceptional Children and Youth: A Preliminary Instrument.

    ERIC Educational Resources Information Center

    Eash, Maurice

    An instrument for the evaluation of instructional materials is presented. Evaluative items are arranged under four constructs: objectives, organization of material (both scope and sequence), methodology, and evaluation. A section is also provided for summary quantitative judgment. A glossary of terms used in the instrument is included. A training…

  3. Kinematic Validation of a Multi-Kinect v2 Instrumented 10-Meter Walkway for Quantitative Gait Assessments.

    PubMed

    Geerse, Daphne J; Coolen, Bert H; Roerdink, Melvyn

    2015-01-01

    Walking ability is frequently assessed with the 10-meter walking test (10MWT), which may be instrumented with multiple Kinect v2 sensors to complement the typical stopwatch-based time to walk 10 meters with quantitative gait information derived from Kinect's 3D body point's time series. The current study aimed to evaluate a multi-Kinect v2 set-up for quantitative gait assessments during the 10MWT against a gold-standard motion-registration system by determining between-systems agreement for body point's time series, spatiotemporal gait parameters and the time to walk 10 meters. To this end, the 10MWT was conducted at comfortable and maximum walking speed, while 3D full-body kinematics was concurrently recorded with the multi-Kinect v2 set-up and the Optotrak motion-registration system (i.e., the gold standard). Between-systems agreement for body point's time series was assessed with the intraclass correlation coefficient (ICC). Between-systems agreement was similarly determined for the gait parameters' walking speed, cadence, step length, stride length, step width, step time, stride time (all obtained for the intermediate 6 meters) and the time to walk 10 meters, complemented by Bland-Altman's bias and limits of agreement. Body point's time series agreed well between the motion-registration systems, particularly so for body points in motion. For both comfortable and maximum walking speeds, the between-systems agreement for the time to walk 10 meters and all gait parameters except step width was high (ICC ≥ 0.888), with negligible biases and narrow limits of agreement. Hence, body point's time series and gait parameters obtained with a multi-Kinect v2 set-up match well with those derived with a gold standard in 3D measurement accuracy. Future studies are recommended to test the clinical utility of the multi-Kinect v2 set-up to automate 10MWT assessments, thereby complementing the time to walk 10 meters with reliable spatiotemporal gait parameters obtained

  4. Kinematic Validation of a Multi-Kinect v2 Instrumented 10-Meter Walkway for Quantitative Gait Assessments

    PubMed Central

    Geerse, Daphne J.; Coolen, Bert H.; Roerdink, Melvyn

    2015-01-01

    Walking ability is frequently assessed with the 10-meter walking test (10MWT), which may be instrumented with multiple Kinect v2 sensors to complement the typical stopwatch-based time to walk 10 meters with quantitative gait information derived from Kinect’s 3D body point’s time series. The current study aimed to evaluate a multi-Kinect v2 set-up for quantitative gait assessments during the 10MWT against a gold-standard motion-registration system by determining between-systems agreement for body point’s time series, spatiotemporal gait parameters and the time to walk 10 meters. To this end, the 10MWT was conducted at comfortable and maximum walking speed, while 3D full-body kinematics was concurrently recorded with the multi-Kinect v2 set-up and the Optotrak motion-registration system (i.e., the gold standard). Between-systems agreement for body point’s time series was assessed with the intraclass correlation coefficient (ICC). Between-systems agreement was similarly determined for the gait parameters’ walking speed, cadence, step length, stride length, step width, step time, stride time (all obtained for the intermediate 6 meters) and the time to walk 10 meters, complemented by Bland-Altman’s bias and limits of agreement. Body point’s time series agreed well between the motion-registration systems, particularly so for body points in motion. For both comfortable and maximum walking speeds, the between-systems agreement for the time to walk 10 meters and all gait parameters except step width was high (ICC ≥ 0.888), with negligible biases and narrow limits of agreement. Hence, body point’s time series and gait parameters obtained with a multi-Kinect v2 set-up match well with those derived with a gold standard in 3D measurement accuracy. Future studies are recommended to test the clinical utility of the multi-Kinect v2 set-up to automate 10MWT assessments, thereby complementing the time to walk 10 meters with reliable spatiotemporal gait parameters

  5. Development of a survey instrument to investigate the primary care factors related to differences in cancer diagnosis between international jurisdictions

    PubMed Central

    2014-01-01

    Background Survival rates following a diagnosis of cancer vary between countries. The International Cancer Benchmarking Partnership (ICBP), a collaboration between six countries with primary care led health services, was set up in 2009 to investigate the causes of these differences. Module 3 of this collaboration hypothesised that an association exists between the readiness of primary care physicians (PCP) to investigate for cancer – the ‘threshold’ risk level at which they investigate or refer to a specialist for consideration of possible cancer – and survival for that cancer (lung, colorectal and ovarian). We describe the development of an international survey instrument to test this hypothesis. Methods The work was led by an academic steering group in England. They agreed that an online survey was the most pragmatic way of identifying differences between the jurisdictions. Research questions were identified through clinical experience and expert knowledge of the relevant literature. A survey comprising a set of direct questions and five clinical scenarios was developed to investigate the hypothesis. The survey content was discussed and refined concurrently and repeatedly with international partners. The survey was validated using an iterative process in England. Following validation the survey was adapted to be relevant to the health systems operating in other jurisdictions and translated into Danish, Norwegian and Swedish, and into Canadian and Australian English. Results This work has produced a survey with face, content and cross cultural validity that will be circulated in all six countries. It could also form a benchmark for similar surveys in countries with similar health care systems. Conclusions The vignettes could also be used as educational resources. This study is likely to impact on healthcare policy and practice in participating countries. PMID:24938306

  6. CARMENES instrument overview

    NASA Astrophysics Data System (ADS)

    Quirrenbach, A.; Amado, P. J.; Caballero, J. A.; Mundt, R.; Reiners, A.; Ribas, I.; Seifert, W.; Abril, M.; Aceituno, J.; Alonso-Floriano, F. J.; Ammler-von Eiff, M.; Antona Jiménez, R.; Anwand-Heerwart, H.; Azzaro, M.; Bauer, F.; Barrado, D.; Becerril, S.; Béjar, V. J. S.; Benítez, D.; Berdiñas, Z. M.; Cárdenas, M. C.; Casal, E.; Claret, A.; Colomé, J.; Cortés-Contreras, M.; Czesla, S.; Doellinger, M.; Dreizler, S.; Feiz, C.; Fernández, M.; Galadí, D.; Gálvez-Ortiz, M. C.; García-Piquer, A.; García-Vargas, M. L.; Garrido, R.; Gesa, L.; Gómez Galera, V.; González Álvarez, E.; González Hernández, J. I.; Grözinger, U.; Guàrdia, J.; Guenther, E. W.; de Guindos, E.; Gutiérrez-Soto, J.; Hagen, H.-J.; Hatzes, A. P.; Hauschildt, P. H.; Helmling, J.; Henning, T.; Hermann, D.; Hernández Castaño, L.; Herrero, E.; Hidalgo, D.; Holgado, G.; Huber, A.; Huber, K. F.; Jeffers, S.; Joergens, V.; de Juan, E.; Kehr, M.; Klein, R.; Kürster, M.; Lamert, A.; Lalitha, S.; Laun, W.; Lemke, U.; Lenzen, R.; López del Fresno, Mauro; López Martí, B.; López-Santiago, J.; Mall, U.; Mandel, H.; Martín, E. L.; Martín-Ruiz, S.; Martínez-Rodríguez, H.; Marvin, C. J.; Mathar, R. J.; Mirabet, E.; Montes, D.; Morales Muñoz, R.; Moya, A.; Naranjo, V.; Ofir, A.; Oreiro, R.; Pallé, E.; Panduro, J.; Passegger, V.-M.; Pérez-Calpena, A.; Pérez Medialdea, D.; Perger, M.; Pluto, M.; Ramón, A.; Rebolo, R.; Redondo, P.; Reffert, S.; Reinhardt, S.; Rhode, P.; Rix, H.-W.; Rodler, F.; Rodríguez, E.; Rodríguez-López, C.; Rodríguez-Pérez, E.; Rohloff, R.-R.; Rosich, A.; Sánchez-Blanco, E.; Sánchez Carrasco, M. A.; Sanz-Forcada, J.; Sarmiento, L. F.; Schäfer, S.; Schiller, J.; Schmidt, C.; Schmitt, J. H. M. M.; Solano, E.; Stahl, O.; Storz, C.; Stürmer, J.; Suárez, J. C.; Ulbrich, R. G.; Veredas, G.; Wagner, K.; Winkler, J.; Zapatero Osorio, M. R.; Zechmeister, M.; Abellán de Paco, F. J.; Anglada-Escudé, G.; del Burgo, C.; Klutsch, A.; Lizon, J. L.; López-Morales, M.; Morales, J. C.; Perryman, M. A. C.; Tulloch, S. M.; Xu, W.

    2014-07-01

    This paper gives an overview of the CARMENES instrument and of the survey that will be carried out with it during the first years of operation. CARMENES (Calar Alto high-Resolution search for M dwarfs with Exoearths with Near-infrared and optical Echelle Spectrographs) is a next-generation radial-velocity instrument under construction for the 3.5m telescope at the Calar Alto Observatory by a consortium of eleven Spanish and German institutions. The scientific goal of the project is conducting a 600-night exoplanet survey targeting ~ 300 M dwarfs with the completed instrument. The CARMENES instrument consists of two separate echelle spectrographs covering the wavelength range from 0.55 to 1.7 μm at a spectral resolution of R = 82,000, fed by fibers from the Cassegrain focus of the telescope. The spectrographs are housed in vacuum tanks providing the temperature-stabilized environments necessary to enable a 1 m/s radial velocity precision employing a simultaneous calibration with an emission-line lamp or with a Fabry-Perot etalon. For mid-M to late-M spectral types, the wavelength range around 1.0 μm (Y band) is the most important wavelength region for radial velocity work. Therefore, the efficiency of CARMENES has been optimized in this range. The CARMENES instrument consists of two spectrographs, one equipped with a 4k x 4k pixel CCD for the range 0.55 - 1.05 μm, and one with two 2k x 2k pixel HgCdTe detectors for the range from 0.95 - 1.7μm. Each spectrograph will be coupled to the 3.5m telescope with two optical fibers, one for the target, and one for calibration light. The front end contains a dichroic beam splitter and an atmospheric dispersion corrector, to feed the light into the fibers leading to the spectrographs. Guiding is performed with a separate camera; on-axis as well as off-axis guiding modes are implemented. Fibers with octagonal cross-section are employed to ensure good stability of the output in the presence of residual guiding errors. The

  7. Development and testing of the Youth Alcohol Norms Survey (YANS) instrument to measure youth alcohol norms and psychosocial influences

    PubMed Central

    Maycock, Bruce; Hildebrand, Janina; Zhao, Yun; Allsop, Steve; Lobo, Roanna; Howat, Peter

    2018-01-01

    Objectives This study aimed to develop and validate an online instrument to: (1) identify common alcohol-related social influences, norms and beliefs among adolescents; (2) clarify the process and pathways through which proalcohol norms are transmitted to adolescents; (3) describe the characteristics of social connections that contribute to the transmission of alcohol norms; and (4) identify the influence of alcohol marketing on adolescent norm development. Setting The online Youth Alcohol Norms Survey (YANS) was administered in secondary schools in Western Australia Participants Using a 2-week test–retest format, the YANS was administered to secondary school students (n=481, age=13–17 years, female 309, 64.2%). Primary and secondary outcome measures The development of the YANS was guided by social cognitive theory and comprised a systematic multistage process including evaluation of content and face validity. A 2-week test–retest format was employed. Exploratory factor analysis was conducted to determine the underlying factor structure of the instrument. Test–retest reliability was examined using intraclass correlation coefficient (ICC) and Cohen’s kappa. Results A five-factor structure with meaningful components and robust factorial loads was identified, and the five factors were labelled as ‘individual attitudes and beliefs’, ‘peer and community identity’, ‘sibling influences’, ‘school and community connectedness’ and ‘injunctive norms’, respectively. The instrument demonstrated stability across the test–retest procedure (ICC=0.68–0.88, Cohen’s kappa coefficient=0.69) for most variables. Conclusions The results support the reliability and factorial validity of this instrument. The YANS presents a promising tool, which enables comprehensive assessment of reciprocal individual, behavioural and environmental factors that influence alcohol-related norms among adolescents. PMID:29764872

  8. U.S. Geological Survey

    NASA Technical Reports Server (NTRS)

    1996-01-01

    The Hydrologic Instrumentation Facility (HIF) at Stennis Space Center is a unique high-tech facility that provides hydrologic instrumentation support to the U. S. Geological Survey and other federal agencies worldwide. The HIF has the responsibility for warehousing, testing, evaluating, designing, repairing, and calibrating numerous pieces of hydrologic instrumentation, which is used in studying water on the surface, in the soil, and in the atmosphere of the Earth.

  9. Sport participation and subjective well-being: instrumental variable results from German survey data.

    PubMed

    Ruseski, Jane E; Humphreys, Brad R; Hallman, Kirstin; Wicker, Pamela; Breuer, Christoph

    2014-02-01

    A major policy goal of many ministries of sport and health is increased participation in sport to promote health. A growing literature is emerging about the benefits of sport participation on happiness. A challenge in establishing a link between sport participation and happiness is controlling for endogeneity of sport participation in the happiness equation. This study seeks to establish causal evidence of a relationship between sport participation and self reported happiness using instrumental variables (IV). IV estimates based on data from a 2009 population survey living in Rheinberg, Germany indicate that individuals who participate in sport have higher life happiness. The results suggest a U-shaped relationship between age and self-reported happiness. Higher income is associated with greater self-reported happiness, males are less happy than females, and single individuals are less happy than nonsingles. Since the results are IV, this finding is interpreted as a causal relationship between sport participation and subjective well-being (SWB). This broader impact of sport participation on general happiness lends support to the policy priority of many governments to increase sport participation at all levels of the general population.

  10. Determination of acid ionization constants for weak acids by osmometry and the instrumental analysis self-evaluation feedback approach to student preparation of solutions

    NASA Astrophysics Data System (ADS)

    Kakolesha, Nyanguila

    One focus of this work was to develop of an alternative method to conductivity for determining the acid ionization constants. Computer-controlled osmometry is one of the emerging analytical tools in industrial research and clinical laboratories. It is slowly finding its way into chemistry laboratories. The instrument's microprocessor control ensures shortened data collection time, repeatability, accuracy, and automatic calibration. The equilibrium constants of acetic acid, chloroacetic acid, bromoacetic acid, cyanoacetic acid, and iodoacetic acid have been measured using osmometry and their values compared with the existing literature values obtained, usually, from conductometric measurements. Ionization constant determined by osmometry for the moderately strong weak acids were in reasonably good agreement with literature values. The results showed that two factors, the ionic strength and the osmotic coefficient, exert opposite effects in solutions of such weak acids. Another focus of the work was analytical chemistry students solution preparation skills. The prevailing teacher-structured experiments leave little room for students' ingenuity in quantitative volumetric analysis. The purpose of this part of the study was to improve students' skills in making solutions using instrument feedback in a constructivist-learning model. After making some solutions by weighing and dissolving solutes or by serial dilution, students used the spectrophotometer and the osmometer to compare their solutions with standard solutions. Students perceived the instrument feedback as a nonthreatening approach to monitoring the development of their skill levels and liked to clarify their understanding through interacting with an instructor-observer. An assessment of the instrument feedback and the constructivist model indicated that students would assume responsibility for their own learning if given the opportunity. This study involved 167 students enrolled in Quantitative Chemical

  11. Transportation forecasting : analysis and quantitative methods

    DOT National Transportation Integrated Search

    1983-01-01

    This Record contains the following papers: Development of Survey Instruments Suitable for Determining Non-Home Activity Patterns; Sequential, History-Dependent Approach to Trip-Chaining Behavior; Identifying Time and History Dependencies of Activity ...

  12. Application of the correlation constrained multivariate curve resolution alternating least-squares method for analyte quantitation in the presence of unexpected interferences using first-order instrumental data.

    PubMed

    Goicoechea, Héctor C; Olivieri, Alejandro C; Tauler, Romà

    2010-03-01

    Correlation constrained multivariate curve resolution-alternating least-squares is shown to be a feasible method for processing first-order instrumental data and achieve analyte quantitation in the presence of unexpected interferences. Both for simulated and experimental data sets, the proposed method could correctly retrieve the analyte and interference spectral profiles and perform accurate estimations of analyte concentrations in test samples. Since no information concerning the interferences was present in calibration samples, the proposed multivariate calibration approach including the correlation constraint facilitates the achievement of the so-called second-order advantage for the analyte of interest, which is known to be present for more complex higher-order richer instrumental data. The proposed method is tested using a simulated data set and two experimental data systems, one for the determination of ascorbic acid in powder juices using UV-visible absorption spectral data, and another for the determination of tetracycline in serum samples using fluorescence emission spectroscopy.

  13. Cross-cultural adaptation of the instrument 'Family Needs Questionnaire'.

    PubMed

    Hora, Edilene Curvelo; de Sousa, Regina Márcia Cardoso

    2009-01-01

    This is a quantitative methodological development study on the cross-cultural adaptation of the 'Family Needs Questionnaire' (FNQ), which is a structured instrument developed in the United States to measure the perceived needs of family members after the Traumatic Brain Injury (TBI) of a relative. This instrument aims to identify important needs presented by family members, whether met or not. The FNQ translation and adaptation followed a particular method, which permitted to achieve semantic, idiomatic, cultural and conceptual equivalence of the instrument version labeled in Portuguese as 'Questionário de Necessidades da Família'. The results of the questionnaire application to 161 family members showed that the instrument content is valid to measure the needs of families of patients with TBI in the Brazilian context.

  14. 10 CFR 34.49 - Radiation surveys.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Radiation surveys. 34.49 Section 34.49 Energy NUCLEAR... RADIOGRAPHIC OPERATIONS Radiation Safety Requirements § 34.49 Radiation surveys. The licensee shall: (a) Conduct surveys with a calibrated and operable radiation survey instrument that meets the requirements of...

  15. 10 CFR 34.49 - Radiation surveys.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Radiation surveys. 34.49 Section 34.49 Energy NUCLEAR... RADIOGRAPHIC OPERATIONS Radiation Safety Requirements § 34.49 Radiation surveys. The licensee shall: (a) Conduct surveys with a calibrated and operable radiation survey instrument that meets the requirements of...

  16. 10 CFR 34.49 - Radiation surveys.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Radiation surveys. 34.49 Section 34.49 Energy NUCLEAR... RADIOGRAPHIC OPERATIONS Radiation Safety Requirements § 34.49 Radiation surveys. The licensee shall: (a) Conduct surveys with a calibrated and operable radiation survey instrument that meets the requirements of...

  17. 10 CFR 34.49 - Radiation surveys.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Radiation surveys. 34.49 Section 34.49 Energy NUCLEAR... RADIOGRAPHIC OPERATIONS Radiation Safety Requirements § 34.49 Radiation surveys. The licensee shall: (a) Conduct surveys with a calibrated and operable radiation survey instrument that meets the requirements of...

  18. 10 CFR 34.49 - Radiation surveys.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Radiation surveys. 34.49 Section 34.49 Energy NUCLEAR... RADIOGRAPHIC OPERATIONS Radiation Safety Requirements § 34.49 Radiation surveys. The licensee shall: (a) Conduct surveys with a calibrated and operable radiation survey instrument that meets the requirements of...

  19. WFIRST: Data/Instrument Simulation Support at IPAC

    NASA Astrophysics Data System (ADS)

    Laine, Seppo; Akeson, Rachel; Armus, Lee; Bennett, Lee; Colbert, James; Helou, George; Kirkpatrick, J. Davy; Meshkat, Tiffany; Paladini, Roberta; Ramirez, Solange; Wang, Yun; Xie, Joan; Yan, Lin

    2018-01-01

    As part of WFIRST Science Center preparations, the IPAC Science Operations Center (ISOC) maintains a repository of 1) WFIRST data and instrument simulations, 2) tools to facilitate scientific performance and feasibility studies using the WFIRST, and 3) parameters summarizing the current design and predicted performance of the WFIRST telescope and instruments. The simulation repository provides access for the science community to simulation code, tools, and resulting analyses. Examples of simulation code with ISOC-built web-based interfaces include EXOSIMS (for estimating exoplanet yields in CGI surveys) and the Galaxy Survey Exposure Time Calculator. In the future the repository will provide an interface for users to run custom simulations of a wide range of coronagraph instrument (CGI) observations and sophisticated tools for designing microlensing experiments. We encourage those who are generating simulations or writing tools for exoplanet observations with WFIRST to contact the ISOC team so we can work with you to bring these to the attention of the broader astronomical community as we prepare for the exciting science that will be enabled by WFIRST.

  20. Personal assistance, income and employment: the spinal injuries survey instrument (SISI) and its application in a sample of people with quadriplegia.

    PubMed

    Rowell, D; Connelly, L B

    2008-06-01

    Our aim was to ascertain what effect access to personal care package (PCP) has on the labour market activities of people who have a spinal cord injury (SCI). We developed a new instrument called the spinal injuries survey instrument (SISI). The SISI is a 35-item instrument, which contains items on health, education, employment, along with measures of personal assistance, mobility and psychological attribution style. The SISI was administered, with the Short Form 36 (SF-36) health status instrument, to 250 people with an SCI. The response rate was 72%. A retrospective, matched case-control sampling approach matched individuals who received a PCP, with a cohort who did not. The matching criteria included the site and severity of spinal lesion, age and gender. Although data on the reliability of the instrument are currently lacking, our empirical results are consistent with other studies: (1) mean annual health care costs (AUD$8741) are comparable with Walsh's estimates (2) SF-36 data support Kreuter's contention that mental health is resilient to SCI and (3) a post-injury employment rate of 29.7% corroborates Murphy et al. We present additional data describing income, educational attainment and family support. Our discussion borrows a conceptualization of disability by Sen, that includes both an 'earning handicap' (an impediment to earn income) and a 'conversion handicap' (an impediment to the enjoyment of income). Our application of the SISI provides evidence of both. The labour income of people with quadriplegia is AUD$10,007 per annum, while diminished health status, increased out-of-pocket health expenditure and loss of time suggest a conversion handicap.

  1. The Friedrich-Lively Instrument to Assess the Impact of Schizophrenia on Siblings (FLIISS): Part I--instrument construction.

    PubMed

    Friedrich, Rose Marie; Lively, Sonja; Rubenstein, Linda; Buckwalter, Kathleen

    2002-01-01

    Siblings of persons with schizophrenia may provide primary or secondary care for their sibling and support to parents who are primary care givers. These siblings experience stress and the accompanying sequelae of decreased quality of life, grief, chronic illness, and symptoms of depression and anxiety. Comprehensive measures of sibling stress have not been published. Before interventions to help siblings can be created, health professionals need such an assessment. The Friedrich-Lively Instrument to Assess the Impact of Schizophrenia on Siblings (FLIISS) has been developed to meet the needs of both health workers and siblings. The instrument has a strong conceptual basis adapted from Pearlin's model of stress in caregiving and was preceded by pilot work that evaluated both quantitative and qualitative data. In this article, (Part I), the development of the instrument and its relationships to the conceptual model are described. Health professionals can use the instrument for collecting information that will increase their ability to identify sources of stress faced by siblings of persons with schizophrenia, and from this assessment they may develop interventions for this underserved population.

  2. Development of the Primary Care Quality-Homeless (PCQ-H) Instrument: A Practical Survey of Patients' Experiences in Primary Care

    PubMed Central

    Kertesz, Stefan. G.; Pollio, David E.; Jones, Richard N.; Steward, Jocelyn; Stringfellow, Erin J.; Gordon, Adam J.; Johnson, Nancy K.; Kim, Theresa A.; Granstaff, Unita; Austin, Erika L.; Young, Alexander S.; Golden, Joya; Davis, Lori L.; Roth, David L.; Holt, Cheryl L.

    2015-01-01

    Background Homeless patients face unique challenges in obtaining primary care responsive to their needs and context. Patient experience questionnaires could permit assessment of patient-centered medical homes for this population, but standard instruments may not reflect homeless patients' priorities and concerns. Objectives This report describes (a) the content and psychometric properties of a new primary care questionnaire for homeless patients and (b) the methods utilized in its development. Methods Starting with quality-related constructs from the Institute of Medicine, we identified relevant themes by interviewing homeless patients and experts in their care. A multidisciplinary team drafted a preliminary set of 78 items. This was administered to homeless-experienced clients (n=563) across 3 VA facilities and 1 non-VA Health Care for the Homeless Program. Using Item Response Theory, we examined Test Information Function curves to eliminate less informative items and devise plausibly distinct subscales. Results The resulting 33-item instrument (Primary Care Quality-Homeless, PCQ-H) has four subscales: Patient-Clinician Relationship (15 items), Cooperation among Clinicians (3 items), Access/Coordination (11 items) and Homeless-Specific Needs (4 items). Evidence for divergent and convergent validity is provided. Test Information Function (TIF) graphs showed adequate informational value to permit inferences about groups for 3 subscales (Relationship, Cooperation and Access/Coordination). The 3-item Cooperation subscale had lower informational value (TIF<5) but had good internal consistency (alpha=0.75) and patients frequently reported problems in this aspect of care. Conclusions Systematic application of qualitative and quantitative methods supported the development of a brief patient-reported questionnaire focused on the primary care of homeless patients and offers guidance for future population-specific instrument development. PMID:25023918

  3. The inclusion of open-ended questions on quantitative surveys of children: Dealing with unanticipated responses relating to child abuse and neglect.

    PubMed

    Lloyd, Katrina; Devine, Paula

    2015-10-01

    Web surveys have been shown to be a viable, and relatively inexpensive, method of data collection with children. For this reason, the Kids' Life and Times (KLT) was developed as an annual online survey of 10 and 11 year old children. Each year, approximately 4,000 children participate in the survey. Throughout the six years that KLT has been running, a range of questions has been asked that are both policy-relevant and important to the lives of children. Given the method employed by the survey, no extremely sensitive questions that might cause the children distress are included. The majority of questions on KLT are closed yielding quantitative data that are analysed statistically; however, one regular open-ended question is included at the end of KLT each year so that the children can suggest questions that they think should be asked on the survey the following year. While most of the responses are innocuous, each year a small minority of children suggest questions on child abuse and neglect. This paper reports the responses to this question and reflects on how researchers can, and should, deal with this issue from both a methodological and an ethical perspective. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Issues in Quantitative Analysis of Ultraviolet Imager (UV) Data: Airglow

    NASA Technical Reports Server (NTRS)

    Germany, G. A.; Richards, P. G.; Spann, J. F.; Brittnacher, M. J.; Parks, G. K.

    1999-01-01

    The GGS Ultraviolet Imager (UVI) has proven to be especially valuable in correlative substorm, auroral morphology, and extended statistical studies of the auroral regions. Such studies are based on knowledge of the location, spatial, and temporal behavior of auroral emissions. More quantitative studies, based on absolute radiometric intensities from UVI images, require a more intimate knowledge of the instrument behavior and data processing requirements and are inherently more difficult than studies based on relative knowledge of the oval location. In this study, UVI airglow observations are analyzed and compared with model predictions to illustrate issues that arise in quantitative analysis of UVI images. These issues include instrument calibration, long term changes in sensitivity, and imager flat field response as well as proper background correction. Airglow emissions are chosen for this study because of their relatively straightforward modeling requirements and because of their implications for thermospheric compositional studies. The analysis issues discussed here, however, are identical to those faced in quantitative auroral studies.

  5. Kiso Supernova Survey (KISS): Survey strategy

    NASA Astrophysics Data System (ADS)

    Morokuma, Tomoki; Tominaga, Nozomu; Tanaka, Masaomi; Mori, Kensho; Matsumoto, Emiko; Kikuchi, Yuki; Shibata, Takumi; Sako, Shigeyuki; Aoki, Tsutomu; Doi, Mamoru; Kobayashi, Naoto; Maehara, Hiroyuki; Matsunaga, Noriyuki; Mito, Hiroyuki; Miyata, Takashi; Nakada, Yoshikazu; Soyano, Takao; Tarusawa, Ken'ichi; Miyazaki, Satoshi; Nakata, Fumiaki; Okada, Norio; Sarugaku, Yuki; Richmond, Michael W.; Akitaya, Hiroshi; Aldering, Greg; Arimatsu, Ko; Contreras, Carlos; Horiuchi, Takashi; Hsiao, Eric Y.; Itoh, Ryosuke; Iwata, Ikuru; Kawabata, Koji S.; Kawai, Nobuyuki; Kitagawa, Yutaro; Kokubo, Mitsuru; Kuroda, Daisuke; Mazzali, Paolo; Misawa, Toru; Moritani, Yuki; Morrell, Nidia; Okamoto, Rina; Pavlyuk, Nikolay; Phillips, Mark M.; Pian, Elena; Sahu, Devendra; Saito, Yoshihiko; Sano, Kei; Stritzinger, Maximilian D.; Tachibana, Yutaro; Taddia, Francesco; Takaki, Katsutoshi; Tateuchi, Ken; Tomita, Akihiko; Tsvetkov, Dmitry; Ui, Takahiro; Ukita, Nobuharu; Urata, Yuji; Walker, Emma S.; Yoshii, Taketoshi

    2014-12-01

    The Kiso Supernova Survey (KISS) is a high-cadence optical wide-field supernova (SN) survey. The primary goal of the survey is to catch the very early light of a SN, during the shock breakout phase. Detection of SN shock breakouts combined with multi-band photometry obtained with other facilities would provide detailed physical information on the progenitor stars of SNe. The survey is performed using a 2.2° × 2.2° field-of-view instrument on the 1.05-m Kiso Schmidt telescope, the Kiso Wide Field Camera (KWFC). We take a 3-min exposure in g-band once every hour in our survey, reaching magnitude g ˜ 20-21. About 100 nights of telescope time per year have been spent on the survey since 2012 April. The number of the shock breakout detections is estimated to be of the order of 1 during our three-year project. This paper summarizes the KISS project including the KWFC observing setup, the survey strategy, the data reduction system, and CBET-reported SNe discovered so far by KISS.

  6. [A new method of processing quantitative PCR data].

    PubMed

    Ke, Bing-Shen; Li, Guang-Yun; Chen, Shi-Min; Huang, Xiang-Yan; Chen, Ying-Jian; Xu, Jun

    2003-05-01

    Today standard PCR can't satisfy the need of biotechnique development and clinical research any more. After numerous dynamic research, PE company found there is a linear relation between initial template number and cycling time when the accumulating fluorescent product is detectable.Therefore,they developed a quantitative PCR technique to be used in PE7700 and PE5700. But the error of this technique is too great to satisfy the need of biotechnique development and clinical research. A better quantitative PCR technique is needed. The mathematical model submitted here is combined with the achievement of relative science,and based on the PCR principle and careful analysis of molecular relationship of main members in PCR reaction system. This model describes the function relation between product quantity or fluorescence intensity and initial template number and other reaction conditions, and can reflect the accumulating rule of PCR product molecule accurately. Accurate quantitative PCR analysis can be made use this function relation. Accumulated PCR product quantity can be obtained from initial template number. Using this model to do quantitative PCR analysis,result error is only related to the accuracy of fluorescence intensity or the instrument used. For an example, when the fluorescence intensity is accurate to 6 digits and the template size is between 100 to 1,000,000, the quantitative result accuracy will be more than 99%. The difference of result error is distinct using same condition,same instrument but different analysis method. Moreover,if the PCR quantitative analysis system is used to process data, it will get result 80 times of accuracy than using CT method.

  7. Advanced Instrumentation for Positron Emission Tomography [PET

    DOE R&D Accomplishments Database

    Derenzo, S. E.; Budinger, T. F.

    1985-04-01

    This paper summarizes the physical processes and medical science goals that underlay modern instrumentation design for Positron Emission Tomography. The paper discusses design factors such as detector material, crystalphototube coupling, shielding geometry, sampling motion, electronics design, time-of-flight, and the interrelationships with quantitative accuracy, spatial resolution, temporal resolution, maximum data rates, and cost.

  8. Joint analyses of open comments and quantitative data: Added value in a job satisfaction survey of hospital professionals.

    PubMed

    Gilles, Ingrid; Mayer, Mauro; Courvoisier, Nelly; Peytremann-Bridevaux, Isabelle

    2017-01-01

    To obtain a comprehensive understanding of the job opinions of hospital professionals by conducting qualitative analyses of the open comments included in a job satisfaction survey and combining these results with the quantitative results. A cross-sectional survey targeting all Lausanne University Hospital professionals was performed in the fall of 2013. The survey considered ten job satisfaction dimensions (e.g. self-fulfilment, workload, management, work-related burnout, organisational commitment, intent to stay) and included an open comment section. Computer-assisted qualitative analyses were conducted on these comments. Satisfaction rates on the included dimensions and professional groups were entered as predictive variables in the qualitative analyses. Of 10 838 hospital professionals, 4978 participated in the survey and 1067 provided open comments. Data from 1045 respondents with usable comments constituted the analytic sample (133 physicians, 393 nurses, 135 laboratory technicians, 247 administrative staff, including researchers, 67 logistic staff, 44 psycho-social workers, and 26 unspecified). Almost a third of the comments addressed scheduling issues, mostly related to problems and exhaustion linked to shifts, work-life balance, and difficulties with colleagues' absences and the consequences for quality of care and patient safety. The other two-thirds related to classic themes included in job satisfaction surveys. Although some comments were provided equally by all professional groups, others were group specific: work and hierarchy pressures for physicians, healthcare quality and patient safety for nurses, skill recognition for administrative staff. Overall, respondents' comments were consistent with their job satisfaction ratings. Open comment analysis provides a comprehensive understanding of hospital professionals' job experiences, allowing better consideration of quality initiatives that match the needs of professionals with reality.

  9. Development and testing of the Youth Alcohol Norms Survey (YANS) instrument to measure youth alcohol norms and psychosocial influences.

    PubMed

    Burns, Sharyn K; Maycock, Bruce; Hildebrand, Janina; Zhao, Yun; Allsop, Steve; Lobo, Roanna; Howat, Peter

    2018-05-14

    This study aimed to develop and validate an online instrument to: (1) identify common alcohol-related social influences, norms and beliefs among adolescents; (2) clarify the process and pathways through which proalcohol norms are transmitted to adolescents; (3) describe the characteristics of social connections that contribute to the transmission of alcohol norms; and (4) identify the influence of alcohol marketing on adolescent norm development. The online Youth Alcohol Norms Survey (YANS) was administered in secondary schools in Western Australia PARTICIPANTS: Using a 2-week test-retest format, the YANS was administered to secondary school students (n=481, age=13-17 years, female 309, 64.2%). The development of the YANS was guided by social cognitive theory and comprised a systematic multistage process including evaluation of content and face validity. A 2-week test-retest format was employed. Exploratory factor analysis was conducted to determine the underlying factor structure of the instrument. Test-retest reliability was examined using intraclass correlation coefficient (ICC) and Cohen's kappa. A five-factor structure with meaningful components and robust factorial loads was identified, and the five factors were labelled as 'individual attitudes and beliefs', 'peer and community identity', 'sibling influences', 'school and community connectedness' and 'injunctive norms', respectively. The instrument demonstrated stability across the test-retest procedure (ICC=0.68-0.88, Cohen's kappa coefficient=0.69) for most variables. The results support the reliability and factorial validity of this instrument. The YANS presents a promising tool, which enables comprehensive assessment of reciprocal individual, behavioural and environmental factors that influence alcohol-related norms among adolescents. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise

  10. [Qualitative and quantitative study of ophthalmologic consultation in France: A multicenter descriptive survey].

    PubMed

    Santiago, P Y; Becquet, F; Zanlonghi, X; Bosc, J M

    2018-02-01

    This study aimed to precisely map current ophthalmologic consultation in France through systematic data collection in one consultation day. Nine ophthalmologic centers participated in the survey, performing 1148 observations of patients aged from 2 to 102 years old, with a mean of 55.12years old and a male/female distribution of 43.8 %/56.2 %. In general, the patients came in either spontaneously (28.8 %) or for follow-up (59.6 %). Emergency consultations comprised 5.7 % of all cases. Comorbidities or major risk factors were found. Most the patients already wore visual correction (82.6 %), mainly glasses (77.3 %). At the end of the consultation, 48.2 % received a prescription for new optical correction. During the interview, 53.3 % of patients reported visual symptoms, most frequently blurriness, distortion or loss of vision. 25.3 % of the patients experienced ocular symptoms such as pain, watery eyes or itching. An ophthalmic disease was the reason for the consultation in 77.1 % of all cases. Its management included medicinal and/or surgical treatment (45.6 % and10.5 % respectively). The necessary tests were performed on site the same day and only 2.6 % of the patients were given a prescription for additional testing to be performed elsewhere in a referral center. From a qualitatively and quantitatively representative sample, this survey describes ophthalmologic consultation in France today in terms of age, male/female distribution, reason for the visit, the proportion of visual correction and other diseases, diagnosis and treatment. Copyright © 2017. Published by Elsevier Masson SAS.

  11. Modified ERT instrumentation for geo-scientific surveys in the historical centre of Mesagne (Brindisi, Southern Italy)

    NASA Astrophysics Data System (ADS)

    Leucci, Giovanni; De Giorgi, Lara; Terenzio Gizzi, Fabrizio; Persico, Raffaele

    2016-04-01

    The town of Mesagne is one of the sites at greatest geological risk in the north Salento peninsula. In the last few decades, the historical centre of Mesagne has been affected by a series of subsidence events, which have, in some cases, resulted in the partial collapse of buildings and road surfaces. The last event was in the January 2014. It caused subsidence phenomenon in a wide area and many families have been forced from their homes. These events have had both social repercussions, causing alarm and emergency situations, and economic repercussions in terms of the expense of restoration. In order to determine the causes of the ground subsidence events, integrated geophysical surveys were undertaken in the historical centre of Mesagne. In addition, the analysis of several wells allowed the 3D model reconstruction related both to the geology and to the groundwater depth in the surveyed areas. With the purpose of estimating the dimensions of the phenomenon and its possible relationship with both specific environmental conditions (for instance groundwater depth variation) and anthropic conditions (for instance the losses in water supply and sanitation) some geophysical measurements were repeated in the time. For this purpose a modified ERT instrumentation together GPR were used. The study led to the production of a detailed description of the subsidence causes that allows a quick action to restore security conditions in the area.

  12. Instrumentation for a dry-pond detention study

    USGS Publications Warehouse

    Pope, L.M.; Jennings, M.E.; Thibodeaux, K.G.

    1988-01-01

    A 12.3-acre, fully urbanized, residential land-use catchment was instrumented by the U. S. Geological Survey in Topeka, Kansas. Hydraulic instrumentation for flow measurement includes two types of flumes, a pipe-insert flume and a culvert-inlet (manhole) flume. Samples of rainfall and runoff for water-quality analyses were collected by automatic, 3-liter, 24-sample capacity water samples controlled by multichannel data loggers. Ancillary equipment included a raingage and wet/dry atmospheric-deposition sampler. Nineteen stormwater runoff events were monitored at the site using the instrumentation system. The system has a high reliability of data capture and permits an accurate determination of storm-water loads.

  13. Racial differences in glucose control among patients with type 2 diabetes: a survey on dietary temptations, coping, and trust in physicians.

    PubMed

    Betancourt, Renée M; Degnan, Kathleen O; Long, Judith A

    2013-01-01

    A quantitative evaluation of self-care behaviors, psychosocial stressors, and patient relationships to health care to better understand racial disparities in these domains. A cross-sectional study of adult patients with type 2 diabetes in University of Pennsylvania Healthcare System who had a HbA1c test within one month of survey administration. The survey instrument included among other items, the Dieter's Inventory of Eating Temptations Self-Efficacy instrument (DIET-SE), the Jalowiec Coping Scale (JCS), and the Trust in Physician (TIP) scale. 332 individuals completed the survey. Poor glucose control was significantly associated with Black race, lower income level, other demographic variables, non-perfect medication adherence, and poorer diet quality. It was also associated with lower self-efficacy to resist social dietary temptations, and among White patients it was associated was decreased use of a confrontive coping style. However, these factors did not explain the racial differences in glucose control between Blacks and Whites. Interventions aimed at dietary temptations, coping styles, or trust in physicians may not reduce racial disparities in glucose control. However, interventions that focus on dietary temptations may positively affect all diabetic patients.

  14. Rapid Quantitative Analysis of Multiple Explosive Compound Classes on a Single Instrument via Flow-Injection Analysis Tandem Mass Spectrometry.

    PubMed

    Ostrinskaya, Alla; Kunz, Roderick R; Clark, Michelle; Kingsborough, Richard P; Ong, Ta-Hsuan; Deneault, Sandra

    2018-05-24

    A flow-injection analysis tandem mass spectrometry (FIA MSMS) method was developed for rapid quantitative analysis of 10 different inorganic and organic explosives. Performance is optimized by tailoring the ionization method (APCI/ESI), de-clustering potentials, and collision energies for each specific analyte. In doing so, a single instrument can be used to detect urea nitrate, potassium chlorate, 2,4,6-trinitrotoluene, 2,4,6-trinitrophenylmethylnitramine, triacetone triperoxide, hexamethylene triperoxide diamine, pentaerythritol tetranitrate, 1,3,5-trinitroperhydro-1,3,5-triazine, nitroglycerin, and octohy-dro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine with sensitivities all in the picogram per milliliter range. In conclusion, FIA APCI/ESI MSMS is a fast (<1 min/sample), sensitive (~pg/mL LOQ), and precise (intraday RSD < 10%) method for trace explosive detection that can play an important role in criminal and attributional forensics, counterterrorism, and environmental protection areas, and has the potential to augment or replace several of the existing explosive detection methods. © 2018 American Academy of Forensic Sciences.

  15. Leadership training in a family medicine residency program: Cross-sectional quantitative survey to inform curriculum development.

    PubMed

    Gallagher, Erin; Moore, Ainsley; Schabort, Inge

    2017-03-01

    To assess the current status of leadership training as perceived by family medicine residents to inform the development of a formal leadership curriculum. Cross-sectional quantitative survey. Department of Family Medicine at McMaster University in Hamilton, Ont, in December 2013. A total of 152 first- and second-year family medicine residents. Family medicine residents' attitudes toward leadership, perceived level of training in various leadership domains, and identified opportunities for leadership training. Overall, 80% (152 of 190) of residents completed the survey. On a Likert scale (1 = strongly disagree, 4 = neutral, 7 = strongly agree), residents rated the importance of physician leadership in the clinical setting as high (6.23 of 7), whereas agreement with the statement "I am a leader" received the lowest rating (5.28 of 7). At least 50% of residents desired more training in the leadership domains of personal mastery, mentorship and coaching, conflict resolution, teaching, effective teamwork, administration, ideals of a healthy workplace, coalitions, and system transformation. At least 50% of residents identified behavioural sciences seminars, a lecture and workshop series, and a retreat as opportunities to expand leadership training. The concept of family physicians as leaders resonated highly with residents. Residents desired more personal and system-level leadership training. They also identified ways that leadership training could be expanded in the current curriculum and developed in other areas. The information gained from this survey might facilitate leadership development among residents through application of its results in a formal leadership curriculum. Copyright© the College of Family Physicians of Canada.

  16. Combined use of frequency-domain electromagnetic and electrical resistivity surveys to delineate near-lake groundwater flow in the semi-arid Nebraska Sand Hills, USA

    USGS Publications Warehouse

    Ong, John B.; Lane, John W.; Zlotnik, Vitaly A.; Halihan, Todd; White, Eric A.

    2010-01-01

    A frequency-domain electromagnetic (FDEM) survey can be used to select locations for the more quantitative and labor-intensive electrical resistivity surveys. The FDEM survey rapidly characterized the groundwater-flow directions and configured the saline plumes caused by evaporation from several groundwater-dominated lakes in the Nebraska Sand Hills, USA. The FDEM instrument was mounted on a fiberglass cart and towed by an all-terrain vehicle, covering about 25 km/day. Around the saline lakes, areas with high electrical conductivity are consistent with the regional and local groundwater flow directions. The efficacy of this geophysical approach is attributed to: the high contrast in electrical conductivity between various groundwater zones; the shallow location of the saline zones; minimal cultural interference; and relative homogeneity of the aquifer materials.

  17. Science Instrument Sensitivities to Radioisotope Power System Environment

    NASA Technical Reports Server (NTRS)

    Bairstow, Brian; Lee, Young; Smythe, William; Zakrajsek, June

    2016-01-01

    Radioisotope Power Systems (RPS) have been and will be enabling or significantly enhancing for many missions, including several concepts identified in the 2011 Planetary Science Decadal Survey. Some mission planners and science investigators might have concerns about possible impacts from RPS-induced conditions upon the scientific capabilities of their mission concepts. To alleviate these concerns, this paper looks at existing and potential future RPS designs, and examines their potential radiation, thermal, vibration, electromagnetic interference (EMI), and magnetic fields impacts on representative science instruments and science measurements. Radiation impacts from RPS on science instruments are of potential concern for instruments with optical detectors and instruments with high-voltage electronics. The two main areas of concern are noise effects on the instrument measurements, and long-term effects of instrument damage. While RPS by their nature will contribute to total radiation dose, their addition for most missions should be relatively small. For example, the gamma dose rate from one Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) would be an order of magnitude lower than the environmental dose rate at Mars, and would have a correspondingly lower contribution to instrument noise and to any permanent damage to payload sensors. Increasing the number of General Purpose Heat Source (GPHS) modules used in an RPS would be expected to increase the generated radiation proportionally; however, the effect of more GPHS modules is mitigated from a strictly linear relationship by self-shielding effects. The radiation field of an RPS is anisotropic due to the deviation of the modules from a point-source-geometry. For particularly sensitive instruments the total radiation dose could be mitigated with separation or application of spot shielding. Though a new, higher-power RPS could generate more heat per unit than current designs, thermal impact to the flight

  18. The School Counselor Leadership Survey: Instrument Development and Exploratory Factor Analysis

    ERIC Educational Resources Information Center

    Young, Anita; Bryan, Julia

    2015-01-01

    This study examined the factor structure of the School Counselor Leadership Survey (SCLS). Survey development was a threefold process that resulted in a 39-item survey of 801 school counselors and school counselor supervisors. The exploratory factor analysis indicated a five-factor structure that revealed five key dimensions of school counselor…

  19. Sexual Experiences Survey: A Research Instrument Investigating Sexual Aggression and Victimization.

    ERIC Educational Resources Information Center

    Koss, Mary P. Oros, Cheryl J.

    1982-01-01

    Developed a survey capable of reflecting hidden cases of rape and of documenting a dimensional view of sexual aggression/sexual victimization. The survey was administered to 3,862 university students. Results supported a dimensional view. Discusses the viability of a survey approach to sample selection for future rape research. (Author)

  20. Video instrumentation for radionuclide angiocardiography.

    NASA Technical Reports Server (NTRS)

    Kriss, J. P.

    1973-01-01

    Two types of videoscintiscopes for performing radioisotopic angiocardiography with a scintillation camera are described, and use of these instruments in performing clinical studies is illustrated. Radionuclide angiocardiography is a simple, quick and accurate procedure recommended as a screening test for patients with a variety of congenital and acquired cardiovascular lesions. When performed in conjunction with coronary arterial catheterization, dynamic radionuclide angiography may provide useful information about regional myocardial perfusion. Quantitative capabilities greatly enhance the potential of this diagnostic tool.

  1. Impact of Lean on surgical instrument reduction: Less is more.

    PubMed

    Wannemuehler, Todd J; Elghouche, Alhasan N; Kokoska, Mimi S; Deig, Christopher R; Matt, Bruce H

    2015-12-01

    To determine whether instrument sets that are frequently used by multiple surgeons can be substantially reduced in size with consensus. Prospective quality improvement study using Lean Six Sigma for purposeful and consensual reduction of non-value-added instruments in adenotonsillectomy instrument sets. Value stream mapping was utilized to determine instrumentation usage and reprocessing workflow. Preintervention instrument utilization surveys allowed consensual and intelligent set reduction. Non-value-added instruments were targeted for waste elimination by placement in a supplemental set. Times for pre- and postintervention instrument assembly, Mayo setup, and surgery were collected for adenotonsillectomies. Postintervention satisfaction surveys of surgeons and staff were conducted. Adenotonsillectomy sets were reduced from 52 to 24 instruments. Median assembly times were significantly reduced from 8.4 to 4.7 minutes (P < .0001) with a set assembly cost reduction of 44%. Following natural log transformations, mean Mayo setup times were significantly reduced from 97.6 to 76.1 seconds (P < .0001), and mean operative times were not significantly affected (1,773 vs. 1,631 seconds, P > .05). The supplemental set was opened in only 3.6% of cases. Satisfaction was >90% regarding the intervention. Set build cost was reduced by $1,468.99 per set. Lean Six Sigma improves efficiency and reduces waste by empowering team members to improve their environment. Instrument set reduction is ideal for waste elimination because of tool accumulation over time and instrument obsolescence as newer technologies are adopted. Similar interventions could easily be applied to larger sinus, mastoidectomy, and spine sets. NA. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  2. Status of ART-XC/SRG Instrument

    NASA Technical Reports Server (NTRS)

    Pavlinsky, M.; Akimov, V.; Levin, V.; Lapshov, I.; Tkachenko, A.; Semena, N.; Buntov, M.; Glushenko, A.; Arefiev, V.; Yaskovich, A.; hide

    2014-01-01

    Spectrum Roentgen Gamma (SRG) is an X-ray astrophysical observatory, developed by Russia in collaboration with Germany. The mission will be launched in March 2016 from Baikonur, by a Zenit rocket with a Fregat booster and placed in a 6-month-period halo orbit around L2. The scientific payload consists of two independent telescopes - a soft-x-ray survey instrument, eROSITA, being provided by Germany and a medium-x-ray-energy survey instrument ART-XC being developed by Russia. ART-XC will consist of seven independent, but co-aligned, telescope modules. The NASA Marshall Space Flight Center (MSFC) is fabricating the flight mirror modules for the ART-XC/SRG. Each mirror module will be aligned with a focal plane CdTe double-sided strip detectors which will operate over the energy range of 6-30 keV, with an angular resolution of less than 1', a field of view of approximately 34' and an expected energy resolution of about 10 percent at 14 keV.

  3. Gender and Participation in High School and College Instrumental Jazz Ensembles

    ERIC Educational Resources Information Center

    McKeage, Kathleen M.

    2004-01-01

    This study is an examination of the relationship between gender and participation in high school and college instrumental jazz ensembles. Student demographic and attitudinal information was collected using the researcher-designed Instrumental Jazz Participation Survey (IJPS). Undergraduate college band students (N = 628) representing 15 programs…

  4. Session Overview and AzTEC Instrument Performance

    NASA Astrophysics Data System (ADS)

    Wilson, Grant; Ade, P. A.; Aretxaga, I.; Austermann, J.; Bock, J. J.; Hughes, D.; Kang, Y.; Kim, S.; Lowenthal, J.; Mauskopf, P.; Scott, K.; Yun, M.

    2006-12-01

    AzTEC is a new 144 element bolometer receiver destined as a first-generation instrument for the Large Millimeter Telescope. >From November 2005 and through January 2006, AzTEC made science observations at the 15m James Clerk Maxwell Telescope (JCMT). Approximately 1/2 of the available time was spent mapping the submillimeter galaxy population in blank and biased fields. Overall, over 1 square degree of sky was mapped with uniform coverage in each of five primary fields making this the largest set of surveys of the submillimeter galaxy population ever performed. Hundreds of new submillimeter galaxies have been detected. Here we discuss the instrument, our mapping technique, and a brief summary of the data reduction process. We conclude with a brief summary of the overall impact of these surveys on our understanding of the submillimeter galaxy population.

  5. Mapping between 6 Multiattribute Utility Instruments.

    PubMed

    Chen, Gang; Khan, Munir A; Iezzi, Angelo; Ratcliffe, Julie; Richardson, Jeff

    2016-02-01

    Cost-utility analyses commonly employ a multiattribute utility (MAU) instrument to estimate the health state utilities, which are needed to calculate quality-adjusted life years. Different MAU instruments predict significantly different utilities, which makes comparison of results from different evaluation studies problematical. This article presents mapping functions ("crosswalks") from 6 MAU instruments (EQ-5D-5L, SF-6D, Health Utilities Index 3 [HUI 3], 15D, Quality of Well-Being [QWB], and Assessment of Quality of Life 8D [AQoL-8D]) to each of the other 5 instruments in the study: a total of 30 mapping functions. Data were obtained from a multi-instrument comparison survey of the public and patients in 7 disease areas conducted in 6 countries (Australia, Canada, Germany, Norway, United Kingdom, and United States). The 8022 respondents were administered each of the 6 study instruments. Mapping equations between each instrument pair were estimated using 4 econometric techniques: ordinary least squares, generalized linear model, censored least absolute deviations, and, for the first time, a robust MM-estimator. Goodness-of-fit indicators for each of the results are within the range of published studies. Transformations reduced discrepancies between predicted utilities. Incremental utilities, which determine the value of quality-related health benefits, are almost perfectly aligned at the sample means. Transformations presented here align the measurement scales of MAU instruments. Their use will increase confidence in the comparability of evaluation studies, which have employed different MAU instruments. © The Author(s) 2015.

  6. Integrated Analysis and Tools for Land Subsidence Surveying and Monitoring: a Semi-Quantitative Approach

    NASA Astrophysics Data System (ADS)

    Mosconi, A.; Pozzoli, A.; Meroni, A.; Gagliano, S.

    2015-10-01

    This paper presents an integrated approach for land subsidence monitoring using measures coming from different sensors. Eni S.p.A., the main Italian oil and gas company, constantly surveys the land with all the state of the art and innovative techniques, and a method able to integrate the results is an important and actual topic. Nowadays the world is a multi-sensor platform, and measure integration is strictly necessary. Combining the different data sources should be done in a clever way, taking advantages from the best performances of each technique. An integrated analysis allows the interpretation of simultaneous temporal series of data, coming from different sources, and try to separate subsidence contributions. With this purpose Exelis VIS in collaboration with Eni S.p.A. customize PISAV (Permanent Interferometric Scatterometer Analysis and Visualization), an ENVI extension able to capitalize on and combine all the different data collected in the surveys. In this article are presented some significant examples to show the potential of this tool in oil and gas activity: a hydrocarbon storage field where the comparison between SAR and production volumes emphasise a correlation between the two measures in few steps; and a hydrocarbon production field with the Satellite Survey Unit (S.S.U.), where SAR, CGPS, piezometers and assestimeters measure in the same area at the same time, giving the opportunity to analyse data contextually. In the integrated analysis performed with PISAV not always a mathematical rigorous study is possible, and a semi-quantitative approach is the only method for results interpretation. As a result, in the first test case strong correlation between injected hydrocarbon volume and vertical displacement were highlighted; in the second one the integrated analysis has different advantages in monitoring the land subsidence: permits a first qualitative "differentiation" of the natural and anthropic component of subsidence, and also gives more

  7. Musical Sound, Instruments, and Equipment

    NASA Astrophysics Data System (ADS)

    Photinos, Panos

    2017-12-01

    'Musical Sound, Instruments, and Equipment' offers a basic understanding of sound, musical instruments and music equipment, geared towards a general audience and non-science majors. The book begins with an introduction of the fundamental properties of sound waves, and the perception of the characteristics of sound. The relation between intensity and loudness, and the relation between frequency and pitch are discussed. The basics of propagation of sound waves, and the interaction of sound waves with objects and structures of various sizes are introduced. Standing waves, harmonics and resonance are explained in simple terms, using graphics that provide a visual understanding. The development is focused on musical instruments and acoustics. The construction of musical scales and the frequency relations are reviewed and applied in the description of musical instruments. The frequency spectrum of selected instruments is explored using freely available sound analysis software. Sound amplification and sound recording, including analog and digital approaches, are discussed in two separate chapters. The book concludes with a chapter on acoustics, the physical factors that affect the quality of the music experience, and practical ways to improve the acoustics at home or small recording studios. A brief technical section is provided at the end of each chapter, where the interested reader can find the relevant physics and sample calculations. These quantitative sections can be skipped without affecting the comprehension of the basic material. Questions are provided to test the reader's understanding of the material. Answers are given in the appendix.

  8. Quantitative diagnostics of soft tissue through viscoelastic characterization using time-based instrumented palpation.

    PubMed

    Palacio-Torralba, Javier; Hammer, Steven; Good, Daniel W; Alan McNeill, S; Stewart, Grant D; Reuben, Robert L; Chen, Yuhang

    2015-01-01

    Although palpation has been successfully employed for centuries to assess soft tissue quality, it is a subjective test, and is therefore qualitative and depends on the experience of the practitioner. To reproduce what the medical practitioner feels needs more than a simple quasi-static stiffness measurement. This paper assesses the capacity of dynamic mechanical palpation to measure the changes in viscoelastic properties that soft tissue can exhibit under certain pathological conditions. A diagnostic framework is proposed to measure elastic and viscous behaviors simultaneously using a reduced set of viscoelastic parameters, giving a reliable index for quantitative assessment of tissue quality. The approach is illustrated on prostate models reconstructed from prostate MRI scans. The examples show that the change in viscoelastic time constant between healthy and cancerous tissue is a key index for quantitative diagnostics using point probing. The method is not limited to any particular tissue or material and is therefore useful for tissue where defining a unique time constant is not trivial. The proposed framework of quantitative assessment could become a useful tool in clinical diagnostics for soft tissue. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  9. Validation of an Instrument to Measure Community College Student Satisfaction

    ERIC Educational Resources Information Center

    Zhai, Lijuan

    2012-01-01

    This article reports the development and validation of a survey instrument to measure community college students' satisfaction with their educational experiences. The initial survey included 95 questions addressing community college student experiences. Data were collected from 558 community college students during spring of 2001. An exploratory…

  10. Analysis of instruments measuring nurses' attitudes towards research utilization: a systematic review.

    PubMed

    Frasure, Jamey

    2008-01-01

    This paper is a report of a systematic review describing instruments used to measure nurses' attitudes towards research utilization. Researchers need to have the tools to measure nurses' attitudes. However, limited literature critically analyses instruments and the concepts that comprise nurses' attitudes towards research utilization. A search of the literature from 1982 to 2007 was performed using the Cumulative Index to Nursing and Allied Health Literature, Health and Psychosocial Instruments, PubMed and MEDLINE data bases. The search terms were nursing research, research utilization, instruments, and nurses' attitudes. A total of 186 sources were identified, of which 25 were reviewed. Fourteen instruments met the criteria for in-depth critical analysis of psychometric properties and concepts, and were included in the final review. Each instrument item was judged to be relevant to direct, indirect, persuasive and overall research utilization as defined by Estabrooks. Instruments were arranged from the strongest to the weakest reliability of the subscales to determine the instrument with the strongest psychometric properties. Indirect and overall research utilization was measured by all of the instruments. Ten instruments measured direct research utilization and nine instruments measured persuasive research utilization. The Research Utilization in Nursing Survey by Estabrooks, as adapted by Kenny, was an instrument with strong psychometric properties measuring all four concepts of nurses' attitudes towards using and participating in research and was clinically feasible. Many published instruments are available for use by nurse researchers to measure nurses' attitude towards research utilization, but only one has been subjected to rigorous testing: the Research Utilization in Nursing Survey by Estabrooks.

  11. SU-E-I-51: Quantitative Assessment of X-Ray Imaging Detector Performance in a Clinical Setting - a Simple Approach Using a Commercial Instrument

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sjoeberg, J; Bujila, R; Omar, A

    2015-06-15

    Purpose: To measure and compare the performance of X-ray imaging detectors in a clinical setting using a dedicated instrument for the quantitative determination of detector performance. Methods: The DQEPro (DQE Instruments Inc., London, Ontario Canada) was used to determine the MTF, NPS and DQE using an IEC compliant methodology for three different imaging modalities: conventional radiography (CsI-based detector), general-purpose radioscopy (CsI-based detector), and mammography (a-Se based detector). The radiation qualities (IEC) RQA-5 and RQA-M-2 were used for the CsI-based and a-Se-based detectors, respectively. The DQEPro alleviates some of the difficulties associated with DQE measurements by automatically positioning test devices overmore » the detector, guiding the user through the image acquisition process and providing software for calculations. Results: A comparison of the NPS showed that the image noise of the a-Se detector was less correlated than the CsI detectors. A consistently higher performance was observed for the a-Se detector at all spatial frequencies (MTF: 0.97@0.25 cy/mm, DQE: 0.72@0.25 cy/mm) and the DQE drops off slower than for the CsI detectors. The CsI detector used for conventional radiography displayed a higher performance at low spatial frequencies compared to the CsI detector used for radioscopy (DQE: 0.65 vs 0.60@0.25 cy/mm). However, at spatial frequencies above 1.3 cy/mm, the radioscopy detector displayed better performance than the conventional radiography detector (DQE: 0.35 vs 0.24@2.00 cy/mm). Conclusion: The difference in the MTF, NPS and DQE that was observed for the two different CsI detectors and the a-Se detector reflect the imaging tasks that the different detector types are intended for. The DQEPro has made the determination and calculation of quantitative metrics of X-ray imaging detector performance substantially more convenient and accessible to undertake in a clinical setting.« less

  12. Cost-effective design of economic instruments in nutrition policy.

    PubMed

    Jensen, Jørgen D; Smed, Sinne

    2007-04-04

    This paper addresses the potential for using economic regulation, e.g. taxes or subsidies, as instruments to combat the increasing problems of inappropriate diets, leading to health problems such as obesity, diabetes 2, cardiovascular diseases etc. in most countries. Such policy measures may be considered as alternatives or supplements to other regulation instruments, including information campaigns, bans or enhancement of technological solutions to the problems of obesity or related diseases. 7 different food tax and subsidy instruments or combinations of instruments are analysed quantitatively. The analyses demonstrate that the average cost-effectiveness with regard to changing the intake of selected nutritional variables can be improved by 10-30 per cent if taxes/subsidies are targeted against these nutrients, compared with targeting selected food categories. Finally, the paper raises a range of issues, which need to be investigated further, before firm conclusions about the suitability of economic instruments in nutrition policy can be drawn.

  13. Cost-effective design of economic instruments in nutrition policy

    PubMed Central

    Jensen, Jørgen D; Smed, Sinne

    2007-01-01

    This paper addresses the potential for using economic regulation, e.g. taxes or subsidies, as instruments to combat the increasing problems of inappropriate diets, leading to health problems such as obesity, diabetes 2, cardiovascular diseases etc. in most countries. Such policy measures may be considered as alternatives or supplements to other regulation instruments, including information campaigns, bans or enhancement of technological solutions to the problems of obesity or related diseases. 7 different food tax and subsidy instruments or combinations of instruments are analysed quantitatively. The analyses demonstrate that the average cost-effectiveness with regard to changing the intake of selected nutritional variables can be improved by 10–30 per cent if taxes/subsidies are targeted against these nutrients, compared with targeting selected food categories. Finally, the paper raises a range of issues, which need to be investigated further, before firm conclusions about the suitability of economic instruments in nutrition policy can be drawn. PMID:17408494

  14. Joint analyses of open comments and quantitative data: Added value in a job satisfaction survey of hospital professionals

    PubMed Central

    Gilles, Ingrid; Mayer, Mauro; Courvoisier, Nelly; Peytremann-Bridevaux, Isabelle

    2017-01-01

    Objective To obtain a comprehensive understanding of the job opinions of hospital professionals by conducting qualitative analyses of the open comments included in a job satisfaction survey and combining these results with the quantitative results. Design A cross-sectional survey targeting all Lausanne University Hospital professionals was performed in the fall of 2013. Material and methods The survey considered ten job satisfaction dimensions (e.g. self-fulfilment, workload, management, work-related burnout, organisational commitment, intent to stay) and included an open comment section. Computer-assisted qualitative analyses were conducted on these comments. Satisfaction rates on the included dimensions and professional groups were entered as predictive variables in the qualitative analyses. Participants Of 10 838 hospital professionals, 4978 participated in the survey and 1067 provided open comments. Data from 1045 respondents with usable comments constituted the analytic sample (133 physicians, 393 nurses, 135 laboratory technicians, 247 administrative staff, including researchers, 67 logistic staff, 44 psycho-social workers, and 26 unspecified). Results Almost a third of the comments addressed scheduling issues, mostly related to problems and exhaustion linked to shifts, work-life balance, and difficulties with colleagues’ absences and the consequences for quality of care and patient safety. The other two-thirds related to classic themes included in job satisfaction surveys. Although some comments were provided equally by all professional groups, others were group specific: work and hierarchy pressures for physicians, healthcare quality and patient safety for nurses, skill recognition for administrative staff. Overall, respondents’ comments were consistent with their job satisfaction ratings. Conclusion Open comment analysis provides a comprehensive understanding of hospital professionals’ job experiences, allowing better consideration of quality

  15. Exoplanetary Science: Instrumentation, Observations, and Expectations

    NASA Technical Reports Server (NTRS)

    McElwain, Michael

    2011-01-01

    More than 700 exoplanets have been discovered and studied using indirect techniques, leading our field into the exciting new era of comparative exoplanetology. However, the direct detection of exoplanetary systems still remains at the sensitivity limits of both ground- and space-based observatories. The development of new technologies for adaptive optics systems and high contrast instruments continues to increase the ability to directly study exoplanets. The scientific impact of these developments has promising prospects for both short and long timescales. In my talk, I will discuss recent highlights from the SEEDS survey and the current instrumentation in use at the Subaru telescope. SEEDS is a high contrast imaging strategic observing program with 120 nights of time allocated at the NAOJ's flagship optical and infrared telescope. I will also describe new instrumentation I designed to improve the SEEDS capabilities and efficiency. Finally, I will briefly discuss the conceptual design of a transiting planet camera to fly as a potential second generation instrument on-board NASA's SOFIA observatory.

  16. ASRDI oxygen technology survey. Volume 6: Flow measurement instrumentation

    NASA Technical Reports Server (NTRS)

    Mann, D. B.

    1974-01-01

    A summary is provided of information available on liquid and gaseous oxygen flowmetering including an evaluation of commercial meters. The instrument types, physical principles of measurement, and performance characteristics are described. Problems concerning flow measurements of less than plus or minus two percent uncertainty are reviewed. Recommendations concerning work on flow reference systems, the use of surrogate fluids, and standard tests for oxygen flow measurements are also presented.

  17. Value And Limitations Of Current Laser Immunology Instrumentation

    NASA Astrophysics Data System (ADS)

    Goldman, John A.

    1982-12-01

    Laser instrumentation for the study of immunologic disease and the immune response, as well as for therapy in immunologic associated diseases is still a very new field. The laser nephelometer is the most standard of the instruments now used, because of its ability to exactly measure and quantitate various materials. Fluorescent techniques to help identify various materials including various subsets of lymphocyte population in concert with monoclonal antibodies is a field for further study and development. The therapeutic use of laser, in immunologic and rheumatic diseases, will depend upon in vitro, and in vivo animal and human design studies.

  18. The state of everyday quantitative EEG use in Canada: A national technologist survey.

    PubMed

    Ng, Marcus C; Gillis, Kara

    2017-07-01

    This study sought to determine the state of quantitative EEG (QEEG) use in Canada, as QEEG may provide a partial solution to the issue of escalating EEG demand against insufficient health care resources. A 10-item survey questionnaire was administered to participants at the annual meeting of the Canadian Association of Electroneurophysiology Technologists, which was held in parallel with the annual meeting of the Canadian Neurological Sciences Federation. At least 70% of the Canadian population has QEEG access through academic medical institutions with applicability to adults and children. QEEG was clinically used 50% in real-time and 50% retrospectively in the critical care and epilepsy monitoring units for long-term monitoring and automated seizure detection. QEEG trend use, montage use, and duration were variable. To cope with insufficient health care resources, QEEG is in surprisingly frequent clinical use across Canada. There is no consensus on optimal QEEG trends and montages. The relative ubiquity of QEEG affords an excellent opportunity for research as increasing EEG demand outpaces dwindling health care resources into the foreseeable future. Copyright © 2017 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  19. Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector

    PubMed Central

    Field, Christopher R.; Lubrano, Adam; Woytowitz, Morgan; Giordano, Braden C.; Rose-Pehrsson, Susan L.

    2014-01-01

    The direct liquid deposition of solution standards onto sorbent-filled thermal desorption tubes is used for the quantitative analysis of trace explosive vapor samples. The direct liquid deposition method yields a higher fidelity between the analysis of vapor samples and the analysis of solution standards than using separate injection methods for vapors and solutions, i.e., samples collected on vapor collection tubes and standards prepared in solution vials. Additionally, the method can account for instrumentation losses, which makes it ideal for minimizing variability and quantitative trace chemical detection. Gas chromatography with an electron capture detector is an instrumentation configuration sensitive to nitro-energetics, such as TNT and RDX, due to their relatively high electron affinity. However, vapor quantitation of these compounds is difficult without viable vapor standards. Thus, we eliminate the requirement for vapor standards by combining the sensitivity of the instrumentation with a direct liquid deposition protocol to analyze trace explosive vapor samples. PMID:25145416

  20. Quantitative detection of trace explosive vapors by programmed temperature desorption gas chromatography-electron capture detector.

    PubMed

    Field, Christopher R; Lubrano, Adam; Woytowitz, Morgan; Giordano, Braden C; Rose-Pehrsson, Susan L

    2014-07-25

    The direct liquid deposition of solution standards onto sorbent-filled thermal desorption tubes is used for the quantitative analysis of trace explosive vapor samples. The direct liquid deposition method yields a higher fidelity between the analysis of vapor samples and the analysis of solution standards than using separate injection methods for vapors and solutions, i.e., samples collected on vapor collection tubes and standards prepared in solution vials. Additionally, the method can account for instrumentation losses, which makes it ideal for minimizing variability and quantitative trace chemical detection. Gas chromatography with an electron capture detector is an instrumentation configuration sensitive to nitro-energetics, such as TNT and RDX, due to their relatively high electron affinity. However, vapor quantitation of these compounds is difficult without viable vapor standards. Thus, we eliminate the requirement for vapor standards by combining the sensitivity of the instrumentation with a direct liquid deposition protocol to analyze trace explosive vapor samples.

  1. Evaluating 'good governance': The development of a quantitative tool in the Greater Serengeti Ecosystem.

    PubMed

    Kisingo, Alex; Rollins, Rick; Murray, Grant; Dearden, Phil; Clarke, Marlea

    2016-10-01

    Protected areas (PAs) can provide important benefits to conservation and to communities. A key factor in the effective delivery of these benefits is the role of governance. There has been a growth in research developing frameworks to evaluate 'good' PA governance, usually drawing on a set of principles that are associated with groups of indicators. In contrast to dominant qualitative approaches, this paper describes the development of a quantitative method for measuring effectiveness of protected area governance, as perceived by stakeholders in the Greater Serengeti Ecosystem in Tanzania. The research developed a quantitative method for developing effectiveness measures of PA governance, using a set of 65 statements related to governance principles developed from a literature review. The instrument was administered to 389 individuals from communities located near PAs in the Greater Serengeti Ecosystem. The results of a factor analysis suggest that statements load onto 10 factors that demonstrate high psychometric validity as measured by factor loadings, explained variance, and Cronbach's alpha reliability. The ten common factors that were extracted were: 1) legitimacy, 2) transparency and accountability, 3) responsiveness, 4) fairness, 5) participation, 6) ecosystem based management (EBM) and connectivity, 7) resilience, 8) achievements, 9) consensus orientation, and 10) power. The paper concludes that quantitative surveys can be used to evaluate governance of protected areas from a community-level perspective. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Descriptive survey of the contextual support for nursing research in 15 countries.

    PubMed

    Uys, Leana R; Newhouse, Robin P; Oweis, Arwa; Liang, Xiaokun

    2013-01-01

    Global research productivity depends on the presence of contextual factors, such as a doctorally prepared faculty, graduate programmes, publication options, that enable the conduct and publication of studies to generate knowledge to inform nursing practice. The current study aimed to develop and test an instrument that measures the level of contextual support for nursing research within a specific country, allowing comparisons between countries. After development of a 20-item survey with seven factors and 11 criteria based on a literature review, a quantitative descriptive e-mail survey design was used. Nurse researchers (N=100) from 22 countries were invited to participate. The response rate was 39% from 15 countries. Ethics approval was obtained by investigators in their country of origin. Results showed wide variation in the level of contextual support. The average total level of support across all countries was 26.8% (standard deviation [SD]=14.97). The greatest variability was in the area of availability of publishing opportunities (ranging between no suitable journals in a country to over 100). The least variability was in the area of availability of local enabling support (SD=7.22). This research showed wide differences in the level of contextual support for nursing research. The survey instrument can be utilised as a country assessment that can be used to strategically plan the building of infrastructure needed to support nursing research. Contextual support for nursing research is an antecedent of strong science. Building infrastructure for nursing science is a priority for global health.

  3. A Survey of Student Reactions to Waubonsee Community College.

    ERIC Educational Resources Information Center

    Vojtisek, James R.

    In order to gain an overall view of student attitudes toward Waubonsee Community College (WCC), determine the strong and weak aspects of WCC, and provide a data base for later comparisons, a standard Educational Testing Service survey instrument was administered to a random sample of about 650 WCC students. The survey instrument used was Student…

  4. Evaluation of Sensor Configurations for Robotic Surgical Instruments.

    PubMed

    Gómez-de-Gabriel, Jesús M; Harwin, William

    2015-10-27

    Designing surgical instruments for robotic-assisted minimally-invasive surgery (RAMIS) is challenging due to constraints on the number and type of sensors imposed by considerations such as space or the need for sterilization. A new method for evaluating the usability of virtual teleoperated surgical instruments based on virtual sensors is presented. This method uses virtual prototyping of the surgical instrument with a dual physical interaction, which allows testing of different sensor configurations in a real environment. Moreover, the proposed approach has been applied to the evaluation of prototypes of a two-finger grasper for lump detection by remote pinching. In this example, the usability of a set of five different sensor configurations, with a different number of force sensors, is evaluated in terms of quantitative and qualitative measures in clinical experiments with 23 volunteers. As a result, the smallest number of force sensors needed in the surgical instrument that ensures the usability of the device can be determined. The details of the experimental setup are also included.

  5. Research and Development on a Public Attitude Instrument for Stuttering

    ERIC Educational Resources Information Center

    St. Louis, Kenneth O.

    2012-01-01

    This paper summarizes research associated with the development of the "Public Opinion Survey of Human Attributes-Stuttering" ("POSHA-S"), a survey instrument designed to provide a worldwide standard measure of public attitudes toward stuttering. Pilot studies with early experimental prototypes of the "POSHA-S" are summarized that relate to…

  6. Patient Satisfaction Survey, 1990-1991

    DTIC Science & Technology

    1991-09-01

    PATIENT SATISFACTION SURVEY 1990-1991 A. David Mangelsdorff, Ph.D., M.P.H. U.S. Army Health Care Studies and Clinical Investigation Activity U.S. Army... Health Association of America (GHAA) Consumer Satisfaction Survey instrument be used to survey potential users of DoD medical treatment facilities (HSC...Orphin, Jr. The Group Health Association of America was helpful in providing the modified GHAA Consumer Satisfaction Survey items. I ossion For DTIC tL

  7. The challenges of integrating instrumentation with inflatable aerodynamic decelerators

    NASA Astrophysics Data System (ADS)

    Swanson, Gregory T.; Cassell, Alan M.; Hughes, Stephen J.; Johnson, R. Keith; Calomino, Anthony M.

    New Entry, Decent, and Landing (EDL) technologies are being explored to facilitate the landing of high mass vehicles. Current EDL technologies are limited due to mass and volume constraints dictated by launch vehicle fairings. Therefore, past and present technologies are now being considered to provide a mass and volume efficient solution, including Inflatable Aerodynamic Decelerators (IADs). To better define the instrumentation challenges posed by IAD technology development, a survey was conducted to identify valuable measurements for ground and flight testing of the flexible materials and structures used in their design. From this survey many sensing technologies and systems were explored specific to the stacked torus IAD, resulting in a down-selection to the most viable prospects. The majority of these systems, including wireless data acquisition, were then rapid prototyped and evaluated during component level testing to determine the best integration techniques specific to a 3m and 6m diameter stacked toroid IAD. Each sensing system was then integrated in support of the Hypersonic Inflatable Aerodynamic Decelerator ground test campaign. In this paper these IAD instrumentation systems are described along with their challenges in comparison to traditional rigid aeroshell systems. Requirements resulting from the survey are listed and instrumentation integration techniques and data acquisition are discussed.

  8. Cancer and the LGBTQ Population: Quantitative and Qualitative Results from an Oncology Providers' Survey on Knowledge, Attitudes, and Practice Behaviors.

    PubMed

    Tamargo, Christina L; Quinn, Gwendolyn P; Sanchez, Julian A; Schabath, Matthew B

    2017-10-07

    Despite growing social acceptance, the LGBTQ population continues to face barriers to healthcare including fear of stigmatization by healthcare providers, and providers' lack of knowledge about LGBTQ-specific health issues. This analysis focuses on the assessment of quantitative and qualitative responses from a subset of providers who identified as specialists that treat one or more of the seven cancers that may be disproportionate in LGBTQ patients. A 32-item web-based survey was emailed to 388 oncology providers at a single institution. The survey assessed: demographics, knowledge, attitudes, and practice behaviors. Oncology providers specializing in seven cancer types had poor knowledge of LGBTQ-specific health needs, with fewer than half of the surveyed providers (49.5%) correctly answering knowledge questions. Most providers had overall positive attitudes toward LGBTQ patients, with 91.7% agreeing they would be comfortable treating this population, and would support education and/or training on LGBTQ-related cancer health issues. Results suggest that despite generally positive attitudes toward the LGBTQ population, oncology providers who treat cancer types most prevalent among the population, lack knowledge of their unique health issues. Knowledge and practice behaviors may improve with enhanced education and training on this population's specific needs.

  9. Instrument specifications and geophysical records for airborne electromagnetic survey of parts of Iron, Baraga, and Dickson Counties, Michigan

    USGS Publications Warehouse

    Heran, William D.; Smith, Bruce D.

    1980-01-01

    The data presented herein is from an airborne electromagnetic INPUT* survey conducted by Geoterrex Limited of Canada for the U.S. Geological Survey. The survey area is located in the central part of the Upper Peninsula of Michigan, within parts of Iron, Baraga, and Dickinson Counties. The general area covered is between 46°00' and 46°30' latitude and 88°00' and 88°30' longitude (fig. 1).The INPUT survey was flown as part of a U.S. Geological Survey CUSMAP (Conterminous United States Mineral Appraisal Program) project focusing on the Iron River 2° quadrangle. The survey was flown in order to provide geophysical information which will aid in an integrated geological assessment of mineral potentials of this part of the Iron River 2° quadrangle. The flight line spacing was chosen to maximize the areal coverage without a loss of resolution of major lithologic and structural features.East-west flight lines were flown 400 feet above ground at 1/2 mile intervals. Aerial photos were used for navigation, and the flight path was recorded on continuous-strip film. A continuously recording total field ground magnetic station was used to monitor variations in the Earth's magnetic field. One north-south line was flown to provide a tie for the magnetic data, which was recorded simultaneously with the electromagnetic data by a sensor mounted in the tail of the aircraft. This report is one of two open-file reports. The map in the other report Heran and Smith (1980) shows locations of the fiducial points, the flight lines, preliminary locations of anomalies and conductive zones; all plotted on an air photomosaic. The latitude and longitude ticks marked on this map are only approximate due to distortion in air photos used to recover the flight line position. This map is preliminary and is not to be considered a final interpretation. The present report contains a description of the instrument specifications, a copy of the ground station magnetic data, and a record of the

  10. Psychometric properties of an instrument to measure nursing students' quality of life.

    PubMed

    Chu, Yanxiang; Xu, Min; Li, Xiuyun

    2015-07-01

    It is important for clinical nursing teachers and managers to recognize the importance of nursing students' quality of life (QOL) since they are the source of future nurses. As yet, there is no quality of life evaluation scale (QOLES) specific to them. This study designed a quantitative instrument for evaluating QOL of nursing students. The study design was a descriptive survey with mixed methods including literature review, panel discussion, Delphi method, and statistical analysis. The data were collected from 880 nursing students from four teaching hospitals in Wuhan, China. The reliability and validity of the scale were tested through completion of the QOLES in a cluster sampling method. The total scale included 18 items in three domains: physical, psychological, and social functional. The cumulative contributing rate of the three common factors was 65.23%. Cronbach's alpha coefficient of the scale was 0.82. This scale had good reliability and validity to evaluate nursing students' QOL. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Teaching in the Knowledge Society: New Skills and Instruments for Teachers

    ERIC Educational Resources Information Center

    Cartelli, Antonio, Ed.

    2006-01-01

    "Teaching in the Knowledge Society: New Skills and Instruments for Teachers" covers a pedagogical survey of the changes induced by information and communication technology (ICT) in today's society and education. It critically analyzes facts, instruments, solutions, and strategies while suggesting interpretations and hypotheses to develop a new way…

  12. Novel spinal instrumentation to enhance osteogenesis and fusion: a preliminary study.

    PubMed

    MacEwan, Matthew R; Talcott, Michael R; Moran, Daniel W; Leuthardt, Eric C

    2016-09-01

    OBJECTIVE Instrumented spinal fusion continues to exhibit high failure rates in patients undergoing multilevel lumbar fusion or pseudarthrosis revision; with Grade II or higher spondylolisthesis; or in those possessing risk factors such as obesity, tobacco use, or metabolic disorders. Direct current (DC) electrical stimulation of bone growth represents a unique surgical adjunct in vertebral fusion procedures, yet existing spinal fusion stimulators are not optimized to enhance interbody fusion. To develop an advanced method of applying DC electrical stimulation to promote interbody fusion, a novel osteogenic spinal system capable of routing DC through rigid instrumentation and into the vertebral bodies was fabricated. A pilot study was designed to assess the feasibility of osteogenic instrumentation and compare the ability of osteogenic instrumentation to promote successful interbody fusion in vivo to standard spinal instrumentation with autograft. METHODS Instrumented, single-level, posterior lumbar interbody fusion (PLIF) with autologous graft was performed at L4-5 in adult Toggenburg/Alpine goats, using both osteogenic spinal instrumentation (plus electrical stimulation) and standard spinal instrumentation (no electrical stimulation). At terminal time points (3 months, 6 months), animals were killed and lumbar spines were explanted for radiographic analysis using a SOMATOM Dual Source Definition CT Scanner and high-resolution Microcat II CT Scanner. Trabecular continuity, radiodensity within the fusion mass, and regional bone formation were examined to determine successful spinal fusion. RESULTS Quantitative analysis of average bone density in pedicle screw beds confirmed that electroactive pedicle screws used in the osteogenic spinal system focally enhanced bone density in instrumented vertebral bodies. Qualitative and quantitative analysis of high-resolution CT scans of explanted lumbar spines further demonstrated that the osteogenic spinal system induced solid

  13. Avionics Instrument Systems Specialist Career Ladder: AFSCs 32531, 32551, 31571, and 32591. Occupational Survey Report.

    ERIC Educational Resources Information Center

    Air Force Occupational Measurement Center, Lackland AFB, TX.

    The Avionics Instrument Systems career ladder (AFSC 325X1) provides flight line and shop maintenance training on aircraft instrument systems, electromechancial instruments, components, and test equipment. Duties involve inspecting, removing, installing, repairing, operating, troubleshooting, overhauling, and modifying systems such as flight and…

  14. ICA Communication Audit Survey Instrument: 1977 Organizational Norms.

    ERIC Educational Resources Information Center

    Goldhaber, Gerald M.; And Others

    Section one of this paper describes the history and development of the "communicaton audit," a system for assessing communication effectiveness in organizations, by the International Communication Association. Section two describes the 16 audits conducted so far and the overall demographic characteristics of the current survey data bank.…

  15. Surveying Consumer Satisfaction to Assess Managed-Care Quality: Current Practices

    PubMed Central

    Gold, Marsha; Wooldridge, Judith

    1995-01-01

    Growing interest in using consumer satisfaction information to enhance quality of care and promote informed consumer choice has accompanied recent expansions in managed care. This article synthesizes information about consumer satisfaction surveys conducted by managed-care plans, government and other agencies, community groups, and purchasers of care. We discuss survey content, methods, and use of consumer survey information. Differences in the use of consumer surveys preclude one instrument or methodology from meeting all needs. The effectiveness of plan-based surveys could be enhanced by increased information on alternative survey instruments and methods and new methodological studies, such as ones developing risk-adjustment methods. PMID:10151887

  16. Nearest Neighbor Averaging and its Effect on the Critical Level and Minimum Detectable Concentration for Scanning Radiological Survey Instruments that Perform Facility Release Surveys.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fournier, Sean Donovan; Beall, Patrick S; Miller, Mark L

    2014-08-01

    Through the SNL New Mexico Small Business Assistance (NMSBA) program, several Sandia engineers worked with the Environmental Restoration Group (ERG) Inc. to verify and validate a novel algorithm used to determine the scanning Critical Level (L c ) and Minimum Detectable Concentration (MDC) (or Minimum Detectable Areal Activity) for the 102F scanning system. Through the use of Monte Carlo statistical simulations the algorithm mathematically demonstrates accuracy in determining the L c and MDC when a nearest-neighbor averaging (NNA) technique was used. To empirically validate this approach, SNL prepared several spiked sources and ran a test with the ERG 102F instrumentmore » on a bare concrete floor known to have no radiological contamination other than background naturally occurring radioactive material (NORM). The tests conclude that the NNA technique increases the sensitivity (decreases the L c and MDC) for high-density data maps that are obtained by scanning radiological survey instruments.« less

  17. Measurements in quantitative research: how to select and report on research instruments.

    PubMed

    Hagan, Teresa L

    2014-07-01

    Measures exist to numerically represent degrees of attributes. Quantitative research is based on measurement and is conducted in a systematic, controlled manner. These measures enable researchers to perform statistical tests, analyze differences between groups, and determine the effectiveness of treatments. If something is not measurable, it cannot be tested.

  18. OCTOCAM: A Workhorse Instrument for the Gemini Telescopes During the Era of LSST

    NASA Astrophysics Data System (ADS)

    Roming, Peter; van der Horst, Alexander; OCTOCAM Team

    2018-01-01

    The decade of the 2020s are planned to be an era of large surveys and giant telescopes. A trademark of this era will be the large number of interesting objects observed daily by high-cadence surveys, such as the LSST. Because of the sheer numbers, only a very small fraction of these interesting objects will be observed with extremely large telescopes. The follow up workhorses during this era will be the 8-meter class telescopes and corresponding instruments that are prepared to pursue these interesting objects. One such workhorse instrument is OCTOCAM, a highly efficient instrument designed to probe the time domain window with simulatenous broad-wavelength coverage. OCTOCAM optimizes the use of Gemini for broadband imaging and spectroscopic single-target observations. The instrument is designed for high temporal resolution, broad spectral coverage, and moderate spectral resolution. OCTOCAM was selected as part of the Gemini instrumentation program in early 2017. Here we provide a description of the science cases to be addressed, overall instrument design, and current status.

  19. Students' Awareness and Perceptions of Learning Engineering: Content and Construct Validation of an Instrument

    ERIC Educational Resources Information Center

    Duncan-Wiles, Daphne S.

    2012-01-01

    With the recent addition of engineering to most K-12 testable state standards, efficient and comprehensive instruments are needed to assess changes in student knowledge and perceptions of engineering. In this study, I developed the Students' Awareness and Perceptions of Learning Engineering (STAPLE) instrument to quantitatively measure fourth…

  20. A Survey of Modes of Student Response Indicative of Musical Learning in Elementary Instrumental Music.

    ERIC Educational Resources Information Center

    Weaver, Molly A.

    This master's thesis reports on a study of the frequency and modes of student responses that demonstrate musical learning in the elementary instrumental music class. Some advances must be made toward more definitive evaluation practices in elementary school instrumental music if instrumental programs are to be justified in terms of improved…

  1. Survey of quantitative antimicrobial consumption per production stage in farrow-to-finish pig farms in Spain

    PubMed Central

    Moreno, Miguel A.

    2014-01-01

    Objectives To characterise antimicrobial use (AMU) per production stage in terms of drugs, routes of application, indications, duration and exposed animals in farrow-to-finish pig farms in Spain. Design Survey using a questionnaire on AMU during the six months prior to the interview, administered in face-to-face interviews completed from April to October 2010. Participants 108 potentially eligible farms covering all the country were selected using a multistage sampling methodology; of these, 33 were excluded because they did not fulfil the participation criteria and 49 were surveyed. Results The rank of the most used antimicrobials per farm and production stage and administration route started with polymyxins (colistin) by feed during the growing and the preweaning phases, followed by β-lactams by feed during the growing and the preweaning phases and by injection during the preweaning phase. Conclusions The study demonstrates that the growing stage (from weaning to the start of finishing) has the highest AMU according to different quantitative indicators (number of records, number of antimicrobials used, percentage of farms reporting use, relative number of exposed animals per farm and duration of exposure); feed is the administration route that produces the highest antimicrobial exposure based on the higher number of exposed animals and the longer duration of treatment; and there are large differences in AMU among individual pig farms. PMID:26392868

  2. Experimenting with brass musical instruments

    NASA Astrophysics Data System (ADS)

    Lo Presto, Michael C.

    2003-07-01

    With the aid of microcomputer hardware and software for the introductory physics laboratory, I have developed several experiments dealing with the properties of brass musical instruments that could be used when covering sound anywhere from an introductory physics laboratory to a course in musical acoustics, or even independent studies. The results of these experiments demonstrate in a quantitative fashion the effects of the mouthpiece and bell on the frequencies of the sound waves and thus the musical pitches produced. Most introductory sources only discuss these effects qualitatively.

  3. ARABIC TRANSLATION AND ADAPTATION OF THE HOSPITAL CONSUMER ASSESSMENT OF HEALTHCARE PROVIDERS AND SYSTEMS (HCAHPS) PATIENT SATISFACTION SURVEY INSTRUMENT.

    PubMed

    Dockins, James; Abuzahrieh, Ramzi; Stack, Martin

    2015-01-01

    To translate and adapt an effective, validated, benchmarked, and widely used patient satisfaction measurement tool for use with an Arabic-speaking population. Translation of survey's items, survey administration process development, evaluation of reliability, and international benchmarking Three hundred-bed tertiary care hospital in Jeddah, Saudi Arabia. 645 patients discharged during 2011 from the hospital's inpatient care units. INTERVENTIONS; The Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) instrument was translated into Arabic, a randomized weekly sample of patients was selected, and the survey was administered via telephone during 2011 to patients or their relatives. Scores were compiled for each of the HCAHPS questions and then for each of the six HCAHPS clinical composites, two non-clinical items, and two global items. Clinical composite scores, as well as the two non-clinical and two global items were analyzed for the 645 respondents. Clinical composites were analyzed using Spearman's correlation coefficient and Cronbach's alpha to demonstrate acceptable internal consistency for these items and scales demonstrated acceptable internal consistency for the clinical composites. (Spearman's correlation coefficient = 0.327 - 0.750, P < 0.01; Cronbach's alpha = 0.516 - 0.851) All ten HCAHPS measures were compared quarterly to US national averages with results that closely paralleled the US benchmarks. . The Arabic translation and adaptation of the HCAHPS is a valid, reliable, and feasible tool for evaluation and benchmarking of inpatient satisfaction in Arabic speaking populations.

  4. 78 FR 52166 - Quantitative Messaging Research

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-22

    ... COMMODITY FUTURES TRADING COMMISSION Quantitative Messaging Research AGENCY: Commodity Futures... survey will follow qualitative message testing research (for which CFTC received fast-track OMB approval... message testing research (for which CFTC received fast-track OMB approval) and is necessary to identify...

  5. Quantitative comparisons of urgent care service providers.

    PubMed

    Qin, Hong; Prybutok, Gayle L; Prybutok, Victor R; Wang, Bin

    2015-01-01

    The purpose of this paper is to develop, validate, and use a survey instrument to measure and compare the perceived quality of three types of US urgent care (UC) service providers: hospital emergency rooms, urgent care centres (UCC), and primary care physician offices. This study develops, validates, and uses a survey instrument to measure/compare differences in perceived service quality among three types of UC service providers. Six dimensions measured the components of service quality: tangibles, professionalism, interaction, accessibility, efficiency, and technical quality. Primary care physicians' offices scored higher for service quality and perceived value, followed by UCC. Hospital emergency rooms scored lower in both quality and perceived value. No significant difference was identified between UCC and primary care physicians across all the perspectives, except for interactions. The homogenous nature of the sample population (college students), and the fact that the respondents were recruited from a single university limits the generalizability of the findings. The patient's choice of a health care provider influences not only the continuity of the care that he or she receives, but compliance with a medical regime, and the evolution of the health care landscape. This work contributes to the understanding of how to provide cost effective and efficient UC services. This study developed and validated a survey instrument to measure/compare six dimensions of service quality for three types of UC service providers. The authors provide valuable data for UC service providers seeking to improve patient perceptions of service quality.

  6. Microbial-based evaluation of foaming events in full-scale wastewater treatment plants by microscopy survey and quantitative image analysis.

    PubMed

    Leal, Cristiano; Amaral, António Luís; Costa, Maria de Lourdes

    2016-08-01

    Activated sludge systems are prone to be affected by foaming occurrences causing the sludge to rise in the reactor and affecting the wastewater treatment plant (WWTP) performance. Nonetheless, there is currently a knowledge gap hindering the development of foaming events prediction tools that may be fulfilled by the quantitative monitoring of AS systems biota and sludge characteristics. As such, the present study focuses on the assessment of foaming events in full-scale WWTPs, by quantitative protozoa, metazoa, filamentous bacteria, and sludge characteristics analysis, further used to enlighten the inner relationships between these parameters. In the current study, a conventional activated sludge system (CAS) and an oxidation ditch (OD) were surveyed throughout a period of 2 and 3 months, respectively, regarding their biota and sludge characteristics. The biota community was monitored by microscopic observation, and a new filamentous bacteria index was developed to quantify their occurrence. Sludge characteristics (aggregated and filamentous biomass contents and aggregate size) were determined by quantitative image analysis (QIA). The obtained data was then processed by principal components analysis (PCA), cross-correlation analysis, and decision trees to assess the foaming occurrences, and enlighten the inner relationships. It was found that such events were best assessed by the combined use of the relative abundance of testate amoeba and nocardioform filamentous index, presenting a 92.9 % success rate for overall foaming events, and 87.5 and 100 %, respectively, for persistent and mild events.

  7. A Life in the Universe Survey

    ERIC Educational Resources Information Center

    LoPresto, Michael C.; Hubble-Zdanowski, Jennifer

    2012-01-01

    The "Life in the Universe Survey" is a twelve-question assessment instrument. Largely based on the factors of the Drake equation, it is designed to survey students' initial estimates of its factors and to gauge how estimates change with instruction. The survey was used in sections of a seminar course focusing specifically on life in the universe…

  8. [Development of MEDUC-PG14 survey to assess postgraduate teaching in medical specialties].

    PubMed

    Pizarro, Margarita; Solís, Nancy; Rojas, Viviana; Díaz, Luis Antonio; Padilla, Oslando; Letelier, Luz María; Aizman, Andrés; Sarfatis, Alberto; Olivos, Trinidad; Soza, Alejandro; Delfino, Alejandro; Latorre, Gonzalo; Ivanovic-Zuvic, Danisa; Hoyl, Trinidad; Bitran, Marcela; Arab, Juan Pablo; Riquelme, Arnoldo

    2015-08-01

    Feedback is one of the most important tools to improve teaching in medical education. To develop an instrument to assess the performance of clinical postgraduate teachers in medical specialties. A qualitative methodology consisting in interviews and focus-groups followed by a quantitative methodology to generate consensus, was employed. After generating the instrument, psychometric tests were performed to assess the construct validity (factor analysis) and reliability (Cronbach’s alpha). Experts in medical education, teachers and residents of a medical school participated in interviews and focus groups. With this information, 26 categories (79 items) were proposed and reduced to 14 items (Likert scale 1-5) by an expert’s Delphi panel, generating the MEDUC-PG14 survey, which was answered by 123 residents from different programs of medical specialties. Construct validity was carried out. Factor analysis showed three domains: Teaching and evaluation, respectful behavior towards patients and health care team, and providing feedback. The global score was 4.46 ± 0.94 (89% of the maximum). One teachers’ strength, as evaluated by their residents was “respectful behavior” with 4.85 ± 0.42 (97% of the maximum). “Providing feedback” obtained 4.09 ± 1.0 points (81.8% of the maximum). MEDUC-PG14 survey had a Cronbach’s alpha coefficient of 0.947. MEDUC-PG14 survey is a useful and reliable guide for teacher evaluation in medical specialty programs. Also provides feedback to improve educational skills of postgraduate clinical teachers.

  9. Improved accuracy in quantitative laser-induced breakdown spectroscopy using sub-models

    USGS Publications Warehouse

    Anderson, Ryan; Clegg, Samuel M.; Frydenvang, Jens; Wiens, Roger C.; McLennan, Scott M.; Morris, Richard V.; Ehlmann, Bethany L.; Dyar, M. Darby

    2017-01-01

    Accurate quantitative analysis of diverse geologic materials is one of the primary challenges faced by the Laser-Induced Breakdown Spectroscopy (LIBS)-based ChemCam instrument on the Mars Science Laboratory (MSL) rover. The SuperCam instrument on the Mars 2020 rover, as well as other LIBS instruments developed for geochemical analysis on Earth or other planets, will face the same challenge. Consequently, part of the ChemCam science team has focused on the development of improved multivariate analysis calibrations methods. Developing a single regression model capable of accurately determining the composition of very different target materials is difficult because the response of an element’s emission lines in LIBS spectra can vary with the concentration of other elements. We demonstrate a conceptually simple “sub-model” method for improving the accuracy of quantitative LIBS analysis of diverse target materials. The method is based on training several regression models on sets of targets with limited composition ranges and then “blending” these “sub-models” into a single final result. Tests of the sub-model method show improvement in test set root mean squared error of prediction (RMSEP) for almost all cases. The sub-model method, using partial least squares regression (PLS), is being used as part of the current ChemCam quantitative calibration, but the sub-model method is applicable to any multivariate regression method and may yield similar improvements.

  10. TAIPAN instrument fibre positioner and Starbug robots: engineering overview

    NASA Astrophysics Data System (ADS)

    Staszak, Nicholas F.; Lawrence, Jon; Brown, David M.; Brown, Rebecca; Zhelem, Ross; Goodwin, Michael; Kuehn, Kyler; Lorente, Nuria P. F.; Nichani, Vijay; Waller, Lew; Case, Scott; Content, Robert; Hopkins, Andrew M.; Klauser, Urs; Pai, Naveen; Mueller, Rolf; Mali, Slavko; Vuong, Minh V.

    2016-07-01

    TAIPAN will conduct a stellar and galaxy survey of the Southern sky. The TAIPAN positioner is being developed as a prototype for the MANIFEST instrument on the GMT. The design for TAIPAN incorporates 150 optical fibres (with an upgrade path to 300) situated within independently controlled robotic positioners known as Starbugs. Starbugs allow precise parallel positioning of individual fibres, thus significantly reducing instrument configuration time and increasing the amount of observing time. Presented is an engineering overview of the UKST upgrade of the completely new Instrument Spider Assembly utilized to support the Starbug Fibre Positioning Robot and current status of the Starbug itself.

  11. Focus determination for the James Webb Space Telescope Science Instruments: A Survey of Methods

    NASA Technical Reports Server (NTRS)

    Davila, Pamela S.; Bolcar, Matthew R.; Boss, B.; Dean, B.; Hapogian, J.; Howard, J.; Unger, B.; Wilson, M.

    2006-01-01

    The James Webb Space Telescope (JWST) is a segmented deployable telescope that will require on-orbit alignment using the Near Infrared Camera as a wavefront sensor. The telescope will be aligned by adjusting seven degrees of freedom on each of 18 primary mirror segments and five degrees of freedom on the secondary mirror to optimize the performance of the telescope and camera at a wavelength of 2 microns. With the completion of these adjustments, the telescope focus is set and the optical performance of each of the other science instruments should then be optimal without making further telescope focus adjustments for each individual instrument. This alignment approach requires confocality of the instruments after integration and alignment to the composite metering structure, which will be verified during instrument level testing at Goddard Space Flight Center with a telescope optical simulator. In this paper, we present the results from a study of several analytical approaches to determine the focus for each instrument. The goal of the study is to compare the accuracies obtained for each method, and to select the most feasible for use during optical testing.

  12. L2 Motivational Self-System and Self-Efficacy: A Quantitative Survey-Based Study

    ERIC Educational Resources Information Center

    Roshandel, Javad; Ghonsooly, Behzad; Ghanizadeh, Afsaneh

    2018-01-01

    The present study explored English as a foreign language (EFL) students' motivation and self-efficacy. This is accomplished by incorporating the ten subfactors of L2 motivational self-system namely; criterion measures, ideal L2 self, ought-to L2 self, family influence, instrumentality promotion, instrumentality prevention, attitudes towards…

  13. Validation of the Neonatal Satisfaction Survey (NSS-8) in six Norwegian neonatal intensive care units: a quantitative cross-sectional study.

    PubMed

    Hagen, Inger Hilde; Svindseth, Marit Følsvik; Nesset, Erik; Orner, Roderick; Iversen, Valentina Cabral

    2018-03-27

    quality of care in NICU. Statistical analysis confirms the instrument's capacity to gauge parents' experiences of NICU. Further research is indicated to validate the survey questionnaire in other Nordic countries and beyond.

  14. A Systematic Review of Student Self-Report Instruments That Assess Student-Teacher Relationships

    ERIC Educational Resources Information Center

    Phillipo, Kate; Conner, Jerusha Osber; Davidson, Shannon; Pope, Denise

    2017-01-01

    Background: A large body of survey-based research asserts that the quality and strength of student-teacher relationships (STRs) predict a host of academic and nonacademic outcomes; however, advances in survey design research have led some to question existing survey instruments' psychometric soundness. Concurrently, qualitative research on STRs…

  15. Photovoltaic remote instrument applications: Assessment of the near-term market

    NASA Technical Reports Server (NTRS)

    Rosenblum, L.; Scudder, L. R.; Poley, W. A.; Bifano, W. J.

    1977-01-01

    A preliminary assessment of the near term market for photovoltaic remote instrument applications is presented. Among the potential users, two market sectors are considered: government and private. However, the majority of the remote systems studied are operated by or for the federal, state, or local governments. Environmental monitoring and surveillance remote instrument systems are discussed. Based on information obtained in this preliminary market survey, a domestic, civilian market of at least 1.3 MW sub pk is forecast for remote instrument systems. This estimate is exclusive of several potentially large scale markets for remote instruments which are identified but for which no hard data is available.

  16. Student Climate Survey, Spring 1998.

    ERIC Educational Resources Information Center

    Truckee Meadows Community Coll., Sparks, NV.

    Every three years, Truckee Meadows Community College (Nevada) administers a student climate survey that measures the attitudes, perceptions, and opinions of its student population. The instrument used to survey the student body was designed with three basic objectives in mind: (1) validate the institutional mission; (2) obtain input regarding the…

  17. Quantitative optical scanning tests of complex microcircuits

    NASA Technical Reports Server (NTRS)

    Erickson, J. J.

    1980-01-01

    An approach for the development of the optical scanner as a screening inspection instrument for microcircuits involves comparing the quantitative differences in photoresponse images and then correlating them with electrical parameter differences in test devices. The existing optical scanner was modified so that the photoresponse data could be recorded and subsequently digitized. A method was devised for applying digital image processing techniques to the digitized photoresponse data in order to quantitatively compare the data. Electrical tests were performed and photoresponse images were recorded before and following life test intervals on two groups of test devices. Correlations were made between differences or changes in the electrical parameters of the test devices.

  18. Effect of changes in an FFQ: comparing data from two national dietary survey instruments among 2-year-olds.

    PubMed

    Kristiansen, A L; Lillegaard, I T L; Lande, B; Andersen, L F

    2013-01-28

    In the interpretation of dietary trends, it is important to consider the potential effect of modifications in the dietary assessment method. Therefore, our objective was to explore the comparability of data obtained at two time points by a semi-quantitative FFQ (SFFQ) which has had slight modifications over time. In the national dietary surveys among Norwegian 2-year-olds, diet was assessed by an SFFQ which underwent modifications between the 1999 survey and the 2007 survey. In the present study, fifty-nine families with a 2-year-old child participated by completing both the SFFQ in a crossover design within a month's time. With regard to the reported intake of energy and nutrients, the largest significant differences observed between the two questionnaires were for carbohydrates and added sugar. According to intake of food groups, significant differences were observed for five out of sixteen food groups. Spearman's correlation coefficients for energy, nutrients and food groups ranged from 0.43 (Ca) to 0.85 (soft drinks). Most Bland-Altman plots indicated broad limits of agreement. The differences between the two questionnaires can be explained by changes in the questionnaires, changes in the food composition databases used and random variation. Comparing differences between the questionnaires by maternal educational level, number of children and type of day care revealed minor differences. In conclusion, this study showed that at the group level there was reasonable comparability between the two questionnaires, except for carbohydrates, added sugar and some food groups. Moreover, there were moderate to high correlations for energy, nutrients and food groups.

  19. Noncontact three-dimensional evaluation of surface alterations and wear in NiTi endodontic instruments.

    PubMed

    Ferreira, Fabiano Guerra; Barbosa, Igor Bastos; Scelza, Pantaleo; Montagnana, Marcello Bulhões; Russano, Daniel; Neff, John; Scelza, Miriam Zaccaro

    2017-09-28

    The aim of this study was to undertake a qualitative and quantitative assessment of nanoscale alterations and wear on the surfaces of nickel-titanium (NiTi) endodontic instruments, before and after use, through a high-resolution, noncontact, three-dimensional optical profiler, and to verify the accuracy of the evaluation method. Cutting blade surfaces of two different brands of NiTi endodontic instruments, Reciproc R25 (n = 5) and WaveOne Primary (n = 5), were examined and compared before and after two uses in simulated root canals made in clear resin blocks. The analyses were performed on three-dimensional images which were obtained from surface areas measuring 211 × 211 µm, located 3 mm from their tips. The quantitative evaluation of the samples was conducted before and after the first and second usage, by the recordings of three amplitude parameters. The data were subjected to statistical analysis at a 5% level of significance. The results revealed statistically significant increases in the surface wear of both instruments groups after the second use. The presence of irregularities was found on the surface topography of all the instruments, before and after use. Regardless of the evaluation stage, most of the defects were observed in the WaveOne instruments. The three-dimensional technique was suitable and effective for the accurate investigation of the same surfaces of the instruments in different periods of time.

  20. Reduction in bacterial counts in infected root canals after rotary or hand nickel-titanium instrumentation--a clinical study.

    PubMed

    Rôças, I N; Lima, K C; Siqueira, J F

    2013-07-01

    To compare the antibacterial efficacy of two instrumentation techniques, one using hand nickel-titanium (NiTi) instruments and the other using rotary NiTi instruments, in root canals of teeth with apical periodontitis. Root canals from single-rooted teeth were instrumented using either hand NiTi instruments in the alternated rotation motion technique or rotary BioRaCe instruments. The irrigant used in both groups was 2.5% NaOCl. DNA extracts from samples taken before and after instrumentation were subjected to quantitative analysis by real-time polymerase chain reaction (qPCR). Qualitative analysis was also performed using presence/absence data from culture and qPCR assays. Bacteria were detected in all S1 samples by both methods. In culture analysis, 45% and 35% of the canals were still positive for bacterial presence after hand and rotary NiTi instrumentation, respectively (P > 0.05). Rotary NiTi instrumentation resulted in significantly fewer qPCR-positive cases (60%) than hand NiTi instrumentation (95%) (P = 0.01). Intergroup comparison of quantitative data showed no significant difference between the two techniques. There was no significant difference in bacterial reduction in infected canals after instrumentation using hand or rotary NiTi instruments. In terms of incidence of positive results for bacteria, culture also showed no significant differences between the groups, but the rotary NiTi instrumentation resulted in more negative results in the more sensitive qPCR analysis. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  1. Compact tracking of surgical instruments through structured markers.

    PubMed

    Alberto Borghese, N; Frosio, I

    2013-07-01

    Virtual and augmented reality surgery calls for reliable and efficient tracking of the surgical instruments in the virtual or real operating theatre. The most diffused approach uses three or more not aligned markers, attached to each instrument and surveyed by a set of cameras. However, the structure required to carry the markers does modify the instrument's mass distribution and can interfere with surgeon movements. To overcome these problems, we propose here a new methodology, based on structured markers, to compute the six degrees of freedom of a surgical instrument. Two markers are attached on the instrument axis and one of them has a stripe painted over its surface. We also introduce a procedure to compute with high accuracy the markers center on the cameras image, even when partially occluded by the instrument's axis or by other structures. Experimental results demonstrate the reliability and accuracy of the proposed approach. The introduction of structured passive markers can open new possibilities to accurate tracking, combining markers detection with real-time image processing.

  2. Infection Control in Retreatment Cases: In Vivo Antibacterial Effects of 2 Instrumentation Systems.

    PubMed

    Rodrigues, Renata C V; Antunes, Henrique S; Neves, Mônica A S; Siqueira, José F; Rôças, Isabela N

    2015-10-01

    This in vivo study compared the antibacterial effects of 2 instrumentation systems in root canal-treated teeth with apical periodontitis. Forty-eight teeth with a single root and a single canal showing post-treatment apical periodontitis were selected for this study. For retreatment, teeth were randomly divided into 2 groups according to the instrumentation system used: Self-Adjusting File (SAF; ReDent-Nova, Ra'anana, Israel) and Twisted File Adaptive (TFA; SybronEndo, Orange, CA). In both groups, 2.5% sodium hypochlorite was the irrigant. Bacteriological samples were taken before (S1) and after chemomechanical preparation (S2). In the TFA group, passive ultrasonic irrigation (PUI) was performed after instrumentation, and samples were also taken after this supplementary step (S2b). DNA was extracted from the clinical samples and subjected to quantitative real-time polymerase chain reaction to evaluate the levels of total bacteria, streptococci, and Enterococcus faecalis. Statistical analyses from quantitative real-time polymerase chain reaction data were performed within groups using the Wilcoxon matched pairs test and between groups using the Mann-Whitney U test and the Fisher exact test with the significance level set at P < .05. Bacteria were detected in S1 samples from 43 teeth, which were then included in the antibacterial experiment. Both SAF and TFA instrumentation protocols showed a highly significant intracanal bacterial reduction (P < .001). Intergroup quantitative comparisons disclosed no significant differences between TFA with or without PUI and SAF (P > .05). PUI did not result in significant improvement in disinfection (P > .05). Both instrumentation systems/treatment protocols were highly effective in significantly reducing the intracanal bacterial counts. No significant difference was observed between the 2 systems in disinfecting the canals of teeth with post-treatment apical periodontitis. Copyright © 2015 American Association of

  3. Nuclear medicine and imaging research (instrumentation and quantitative methods of evaluation): Comprehensive 3-year progress report for the period January 15, 1986-January 14, 1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beck, R.N.; Cooper, M.D.

    1988-06-01

    This program addresses the problems involving the basic science and technology underlying the physical and conceptual tools of radioactive tracer methodology as they relate to the measurement of structural and functional parameters of physiologic importance in health and disease. The principal tool is quantitative radionuclide imaging. The overall objective of this program is to further the development and transfer of radiotracer methodology from basic theory to routine clinical practice in order that individual patients and society as a whole will receive the maximum net benefit from the new knowledge gained. The focus of the research is on the development ofmore » new instruments and radiopharmaceuticals, and the evaluation of these through the phase of clinical feasibility. 58 refs., 15 figs., 4 tabs.« less

  4. Detailed Quantitative Classifications of Galaxy Morphology

    NASA Astrophysics Data System (ADS)

    Nair, Preethi

    2018-01-01

    Understanding the physical processes responsible for the growth of galaxies is one of the key challenges in extragalactic astronomy. The assembly history of a galaxy is imprinted in a galaxy’s detailed morphology. The bulge-to-total ratio of galaxies, the presence or absence of bars, rings, spiral arms, tidal tails etc, all have implications for the past merger, star formation, and feedback history of a galaxy. However, current quantitative galaxy classification schemes are only useful for broad binning. They cannot classify or exploit the wide variety of galaxy structures seen in nature. Therefore, comparisons of observations with theoretical predictions of secular structure formation have only been conducted on small samples of visually classified galaxies. However large samples are needed to disentangle the complex physical processes of galaxy formation. With the advent of large surveys, like the Sloan Digital Sky Survey (SDSS) and the upcoming Large Synoptic Survey Telescope (LSST) and WFIRST, the problem of statistics will be resolved. However, the need for a robust quantitative classification scheme will still remain. Here I will present early results on promising machine learning algorithms that are providing detailed classifications, identifying bars, rings, multi-armed spiral galaxies, and Hubble type.

  5. Validation of the National Institutes of Health Patient-Reported Outcomes Measurement Information System Survey as a Quality-of-Life Instrument for Patients with Malignant Brain Tumors and Their Caregivers.

    PubMed

    Romero, Melissa M; Flood, Lisa Sue; Gasiewicz, Nanci K; Rovin, Richard; Conklin, Samantha

    2015-12-01

    At present there is a lack of well-validated surveys used to measure quality of life in patients with malignant brain tumors and their caregivers. The main objective of this pilot study was to validate the National Institutes of Health Patient-Reported Outcomes Measurement Information System (NIH PROMIS) survey for use as a quality-of-life measure in this population. This article presents the rationale for using the NIH PROMIS instrument as a quality-of-life measure for patients with malignant brain tumors and their caregivers. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Methodology for estimating dietary data from the semi-quantitative food frequency questionnaire of the Mexican National Health and Nutrition Survey 2012.

    PubMed

    Ramírez-Silva, Ivonne; Jiménez-Aguilar, Alejandra; Valenzuela-Bravo, Danae; Martinez-Tapia, Brenda; Rodríguez-Ramírez, Sonia; Gaona-Pineda, Elsa Berenice; Angulo-Estrada, Salomón; Shamah-Levy, Teresa

    2016-01-01

    To describe the methodology used to clean up and estimate dietary intake (DI) data from the Semi-Quantitative Food Frequency Questionnaire (SFFQ) of the Mexican National Health and Nutrition Survey 2012. DI was collected through a shortterm SFFQ regarding 140 foods (from October 2011 to May 2012). Energy and nutrient intake was calculated according to a nutrient database constructed specifically for the SFFQ. A total of 133 nutrients including energy and fiber were generated from SFFQ data. Between 4.8 and 9.6% of the survey sample was excluded as a result of the cleaning process.Valid DI data were obtained regarding energy and nutrients consumed by 1 212 pre-school children, 1 323 school children, 1 961 adolescents, 2 027 adults and 526 older adults. We documented the methodology used to clean up and estimate DI from the SFFQ used in national dietary assessments in Mexico.

  7. Plant Biology Personnel and Training at Doctorate-Granting Institutions. Higher Education Surveys Report. Survey Number 13.

    ERIC Educational Resources Information Center

    Chaney, Bradford; And Others

    A survey instrument was sent to all doctorate-granting institutions and all institutions identified as offering doctorates in plant biology. Doctorate-granting institutions were identified using the U.S. Department of Education's Higher Education General Information Surveys (HEGIS) listings. Responses were received from plant biology program…

  8. Digital Education Governance: Data Visualization, Predictive Analytics, and "Real-Time" Policy Instruments

    ERIC Educational Resources Information Center

    Williamson, Ben

    2016-01-01

    Educational institutions and governing practices are increasingly augmented with digital database technologies that function as new kinds of policy instruments. This article surveys and maps the landscape of digital policy instrumentation in education and provides two detailed case studies of new digital data systems. The Learning Curve is a…

  9. Development and Validation of an Assessment Instrument for Course Experience in a General Education Integrated Science Course

    ERIC Educational Resources Information Center

    Liu, Juhong Christie; St. John, Kristen; Courtier, Anna M. Bishop

    2017-01-01

    Identifying instruments and surveys to address geoscience education research (GER) questions is among the high-ranked needs in a 2016 survey of the GER community (St. John et al., 2016). The purpose of this study was to develop and validate a student-centered assessment instrument to measure course experience in a general education integrated…

  10. Development and testing of the Survey of Family Environment (SFE): a novel instrument to measure family functioning and needs for family support.

    PubMed

    Hohashi, Naohiro; Honda, Junko

    2012-01-01

    Hohashi's Concentric Sphere Family Environment Model (CSFEM; Hohashi & Honda, 2011) is a newly proposed family nursing theory for holistically understanding the family environment that acts on family well-being. The purpose of this article is to develop and psychometrically test the Japanese version of the Survey of Family Environment (SFE-J), grounded in the CSFEM, for measuring family's perceived family functioning and family's perceived needs for family support. The SFE-J is a 30-item self-administered instrument that assesses five domains (suprasystem, macrosystem, microsystem, family internal environment system, and chronosystem) and has been subjected to rigorous reliability and validity investigations among paired partners in child-rearing families (N of family = 1,990). Internal consistency reliability was high as measured by Cronbach's alpha coefficients. Temporal stability over a 2-week interval was supported by high (substantial or perfect) and significant intraclass correlation coefficients. The total score for the SFE-J was significantly correlated with the Japanese version of the Feetham Family Functioning Survey (FFFS-J), indicating an acceptable concurrent validity. Construct validity was supported by a confirmatory factor analysis that evaluated the five-factor structure to measure the concept of CSFEM. Results also demonstrate that the SFE-J family functioning scores show no significant differences between paired partners. The SFE-J is a reliable and valid instrument to assess not only intrafamily functioning but also interfamily functioning and, by identifying items/domains with high requirements for family support, serves to facilitate the providing of appropriate support to families.

  11. Cancer and the LGBTQ Population: Quantitative and Qualitative Results from an Oncology Providers’ Survey on Knowledge, Attitudes, and Practice Behaviors

    PubMed Central

    Tamargo, Christina L.; Sanchez, Julian A.

    2017-01-01

    Background: Despite growing social acceptance, the LGBTQ population continues to face barriers to healthcare including fear of stigmatization by healthcare providers, and providers’ lack of knowledge about LGBTQ-specific health issues. This analysis focuses on the assessment of quantitative and qualitative responses from a subset of providers who identified as specialists that treat one or more of the seven cancers that may be disproportionate in LGBTQ patients. Methods: A 32-item web-based survey was emailed to 388 oncology providers at a single institution. The survey assessed: demographics, knowledge, attitudes, and practice behaviors. Results: Oncology providers specializing in seven cancer types had poor knowledge of LGBTQ-specific health needs, with fewer than half of the surveyed providers (49.5%) correctly answering knowledge questions. Most providers had overall positive attitudes toward LGBTQ patients, with 91.7% agreeing they would be comfortable treating this population, and would support education and/or training on LGBTQ-related cancer health issues. Conclusion: Results suggest that despite generally positive attitudes toward the LGBTQ population, oncology providers who treat cancer types most prevalent among the population, lack knowledge of their unique health issues. Knowledge and practice behaviors may improve with enhanced education and training on this population’s specific needs. PMID:28991160

  12. Rethinking Traditional Methods of Survey Validation

    ERIC Educational Resources Information Center

    Maul, Andrew

    2017-01-01

    It is commonly believed that self-report, survey-based instruments can be used to measure a wide range of psychological attributes, such as self-control, growth mindsets, and grit. Increasingly, such instruments are being used not only for basic research but also for supporting decisions regarding educational policy and accountability. The…

  13. Measuring Alcohol Consumption in Population Surveys: A Review of International Guidelines and Comparison with Surveys in England

    PubMed Central

    Nugawela, Manjula D.; Langley, Tessa; Szatkowski, Lisa; Lewis, Sarah

    2016-01-01

    Aims To review the international guidelines and recommendations on survey instruments for measurement of alcohol consumption in population surveys and to examine how national surveys in England meet the core recommendations. Methods A systematic search for international guidelines for measuring alcohol consumption in population surveys was undertaken. The common core recommendations for alcohol consumption measures and survey instruments were identified. Alcohol consumption questions in national surveys in England were compared with these recommendations for specific years and over time since 2000. Results Four sets of international guidelines and three core alcohol consumption measures (alcohol consumption status, average volume of consumption, frequency and volume of heavy episodic drinking) with another optional measure (drinking context) were identified. English national surveys have been inconsistent over time in including questions that provide information on average volume of consumption but have not included questions on another essential alcohol consumption measure, frequency of heavy episodic drinking. Instead, they have used questions that focus only on maximum volume of alcohol consumed on any day in the previous week. Conclusions International guidelines provide consistent recommendations for measuring alcohol consumption in population surveys. These recommendations have not been consistently applied in English national surveys, and this has contributed to the inadequacy of survey measurements for monitoring vital aspects of alcohol consumption in England over recent years. PMID:26115987

  14. Investigation of Music Student Efficacy as Influenced by Age, Experience, Gender, Ethnicity, and Type of Instrument Played in South Carolina

    ERIC Educational Resources Information Center

    White, Norman

    2010-01-01

    The purpose of this research study was to quantitatively examine South Carolina high school instrumental music students' self-efficacy as measured by the Generalized Self-Efficacy (GSE) instrument (Schwarzer & Jerusalem, 1993). The independent variables of age, experience, gender, ethnicity, and type of instrument played) were correlated with…

  15. Evaluation of Sensor Configurations for Robotic Surgical Instruments

    PubMed Central

    Gómez-de-Gabriel, Jesús M.; Harwin, William

    2015-01-01

    Designing surgical instruments for robotic-assisted minimally-invasive surgery (RAMIS) is challenging due to constraints on the number and type of sensors imposed by considerations such as space or the need for sterilization. A new method for evaluating the usability of virtual teleoperated surgical instruments based on virtual sensors is presented. This method uses virtual prototyping of the surgical instrument with a dual physical interaction, which allows testing of different sensor configurations in a real environment. Moreover, the proposed approach has been applied to the evaluation of prototypes of a two-finger grasper for lump detection by remote pinching. In this example, the usability of a set of five different sensor configurations, with a different number of force sensors, is evaluated in terms of quantitative and qualitative measures in clinical experiments with 23 volunteers. As a result, the smallest number of force sensors needed in the surgical instrument that ensures the usability of the device can be determined. The details of the experimental setup are also included. PMID:26516863

  16. Rasch Analysis for Instrument Development: Why, When, and How?

    PubMed Central

    Boone, William J.

    2016-01-01

    This essay describes Rasch analysis psychometric techniques and how such techniques can be used by life sciences education researchers to guide the development and use of surveys and tests. Specifically, Rasch techniques can be used to document and evaluate the measurement functioning of such instruments. Rasch techniques also allow researchers to construct “Wright maps” to explain the meaning of a test score or survey score and develop alternative forms of tests and surveys. Rasch techniques provide a mechanism by which the quality of life sciences–related tests and surveys can be optimized and the techniques can be used to provide a context (e.g., what topics a student has mastered) when explaining test and survey results. PMID:27856555

  17. Development of a patient safety climate survey for Chinese hospitals: cross-national adaptation and psychometric evaluation.

    PubMed

    Zhu, Junya; Li, Liping; Zhao, Hailei; Han, Guangshu; Wu, Albert W; Weingart, Saul N

    2014-10-01

    Existing patient safety climate instruments, most of which have been developed in the USA, may not accurately reflect the conditions in the healthcare systems of other countries. To develop and evaluate a patient safety climate instrument for healthcare workers in Chinese hospitals. Based on a review of existing instruments, expert panel review, focus groups and cognitive interviews, we developed items relevant to patient safety climate in Chinese hospitals. The draft instrument was distributed to 1700 hospital workers from 54 units in six hospitals in five Chinese cities between July and October 2011, and 1464 completed surveys were received. We performed exploratory and confirmatory factor analyses and estimated internal consistency reliability, within-unit agreement, between-unit variation, unit-mean reliability, correlation between multi-item composites, and association between the composites and two single items of perceived safety. The final instrument included 34 items organised into nine composites: institutional commitment to safety, unit management support for safety, organisational learning, safety system, adequacy of safety arrangements, error reporting, communication and peer support, teamwork and staffing. All composites had acceptable unit-mean reliabilities (≥0.74) and within-unit agreement (Rwg ≥0.71), and exhibited significant between-unit variation with intraclass correlation coefficients ranging from 9% to 21%. Internal consistency reliabilities ranged from 0.59 to 0.88 and were ≥0.70 for eight of the nine composites. Correlations between composites ranged from 0.27 to 0.73. All composites were positively and significantly associated with the two perceived safety items. The Chinese Hospital Survey on Patient Safety Climate demonstrates adequate dimensionality, reliability and validity. The integration of qualitative and quantitative methods is essential to produce an instrument that is culturally appropriate for Chinese hospitals

  18. National Beef Quality Audit-2011: Survey of instrument grading assessments of beef carcass characteristics

    USDA-ARS?s Scientific Manuscript database

    The instrument grading assessments for the 2011 National Beef Quality Audit evaluated seasonal trends of beef carcass quality and yield attributes over the course of the year. One week of instrument grading data, HCW, gender, USDA quality grade (QG), and yield grade (YG) factors, were collected ever...

  19. Sexual Harassment Prevention Initiatives: Quantitative and Qualitative Approaches

    DTIC Science & Technology

    2010-10-28

    design , and the time series with nonequivalent control group design . The experimental research approach will randomly assign participants...Leedy & Ormrod, 2005). According to Fife- Schaw (2006) there are three quasi-experimental designs : the nonequivalent control group design , the time...that have controlled and isolated variables. A specific quantitative approach available to the researcher is the use of surveys. Surveys, in

  20. Design of dental surgeries in relation to instrument decontamination.

    PubMed

    Smith, A J; Lockhart, D E A; McDonald, E; Creanor, S; Hurrell, D; Bagg, J

    2010-12-01

    Recent guidelines advise that the decontamination of dental instruments should be undertaken outwith the treatment area. The aim of this study was to determine the physical area of rooms in dental surgeries that decontaminate instruments within and outwith the treatment area respectively, and other factors relating to practice layout and ventilation. Data were collected by interview and observation of dental healthcare workers in dental practice in Scotland, UK. Room layouts were recorded and measured at floor, benchtop and above benchtop heights. Thirteen surgeries with instrument decontamination processes occurring in the treatment area and seven surgeries with instrument decontamination outwith the treatment area were selected at random for detailed analysis of room dimensions. Of the 179 dental surgeries surveyed, 55% were located in converted residential premises and most practitioners (91%) did not share premises with other healthcare providers. The median number of rooms in the practices was 8 (range: 2-21) and the median number of surgeries present was 3 (range: 1-6). Regardless of whether instrument decontamination facilities were housed within the treatment area or not, the average treatment area room size for both was 15.8m(2) (range: 7.3-23.9) (P=0.862), with 20% of the room area available as work surfaces. The median size of the seven instrument decontamination rooms (local decontamination units) was 7.6m(2) (range: 2.9-16.0), with, on average, 63% of the room used for work surfaces. This survey suggests that the historical location of dental surgeries in converted residential properties places many restrictions on appropriate design for healthcare premises. Copyright © 2010 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

  1. Locating Tests and Measurement Instruments for Assessment

    ERIC Educational Resources Information Center

    Mastel, Kristen; Morris-Knower, Jim; Marsalis, Scott

    2016-01-01

    Extension educators, staff, and specialists need to use surveys and other measurement instruments to assess their programming and conduct other research. Challenges in locating tests and measurement tools, however, include lack of time and lack of familiarity with techniques that can be used to find them. This article discusses library resources…

  2. New Instruments for Survey: on Line Softwares for 3d Recontruction from Images

    NASA Astrophysics Data System (ADS)

    Fratus de Balestrini, E.; Guerra, F.

    2011-09-01

    3d scanning technologies had a significant development and have been widely used in documentation of cultural, architectural and archeological heritages. Modern methods of three-dimensional acquiring and modeling allow to represent an object through a digital model that combines visual potentialities of images (normally used for documentation) to the accuracy of the survey, becoming at the same time support for the visualization that for metric evaluation of any artefact that have an historical or artistic interest, opening up new possibilities for cultural heritage's fruition, cataloging and study. Despite this development, because of the small catchment area and the 3D laser scanner's sophisticated technologies, the cost of these instruments is very high and beyond the reach of most operators in the field of cultural heritages. This is the reason why they have appeared low-cost technologies or even free, allowing anyone to approach the issues of acquisition and 3D modeling, providing tools that allow to create three-dimensional models in a simple and economical way. The research, conducted by the Laboratory of Photogrammetry of the University IUAV of Venice, of which we present here some results, is intended to figure out whether, with Arc3D, it is possible to obtain results that can be somehow comparable, in therms of overall quality, to those of the laser scanner, and/or whether it is possible to integrate them. They were carried out a series of tests on certain types of objects, models made with Arc3D, from raster images, were compared with those obtained using the point clouds from laser scanner. We have also analyzed the conditions for an optimal use of Arc3D: environmental conditions (lighting), acquisition tools (digital cameras) and type and size of objects. After performing the tests described above, we analyzed the patterns generated by Arc3D to check what other graphic representations can be obtained from them: orthophotos and drawings. The research

  3. Perceived leader integrity and employee job satisfaction: A quantitative study of U.S. aerospace engineers

    NASA Astrophysics Data System (ADS)

    Harper, Kay E.

    The goal of this quantitative study was to determine if there is a significant relationship between perceived leader integrity and employee job satisfaction. The population selected to be analyzed was U.S. Aerospace engineers. Two existing valid and reliable survey instruments were used to collect data. One of the surveys was the Perceived Leader Integrity Scale developed by Craig and Gustafson. The second survey was the Minnesota Satisfaction Questionnaire created by Weiss, Dawis, England, and Lofquist. The public professional networking site LinkedIn was used to invite U.S. Aerospace engineers to participate. The survey results were monitored by Survey Monkey and the sample data was analyzed using SPSS software. 184 responses were collected and of those, 96 were incomplete. 91 usable survey responses were left to be analyzed. When the results were plotted on an x-y plot, the data line had a slight negative slope. The plotted data showed a very small negative relationship between perceived leader integrity and employee job satisfaction. This relationship could be interpreted to mean that as perceived leader integrity improved, employee job satisfaction decreased only slightly. One explanation for this result could be that employees focused on their negative feelings about their current job assignment when they did not have to be concerned about the level of integrity with which their leader acted. The findings of this study reinforce the importance of employee's perception of a critical leader quality - integrity. For future research, a longitudinal study utilizing another sampling method other than convenience sampling may better statistically capture the relationship between perceived leader integrity and employee job satisfaction for U.S. aerospace engineers.

  4. Considerations in comparing the U.S. Geological Survey one‐year induced‐seismicity hazard models with “Did You Feel It?” and instrumental data

    USGS Publications Warehouse

    White, Isabel; Liu, Taojun; Luco, Nicolas; Liel, Abbie

    2017-01-01

    The recent steep increase in seismicity rates in Oklahoma, southern Kansas, and other parts of the central United States led the U.S. Geological Survey (USGS) to develop, for the first time, a probabilistic seismic hazard forecast for one year (2016) that incorporates induced seismicity. In this study, we explore a process to ground‐truth the hazard model by comparing it with two databases of observations: modified Mercalli intensity (MMI) data from the “Did You Feel It?” (DYFI) system and peak ground acceleration (PGA) values from instrumental data. Because the 2016 hazard model was heavily based on earthquake catalogs from 2014 to 2015, this initial comparison utilized observations from these years. Annualized exceedance rates were calculated with the DYFI and instrumental data for direct comparison with the model. These comparisons required assessment of the options for converting hazard model results and instrumental data from PGA to MMI for comparison with the DYFI data. In addition, to account for known differences that affect the comparisons, the instrumental PGA and DYFI data were declustered, and the hazard model was adjusted for local site conditions. With these adjustments, examples at sites with the most data show reasonable agreement in the exceedance rates. However, the comparisons were complicated by the spatial and temporal completeness of the instrumental and DYFI observations. Furthermore, most of the DYFI responses are in the MMI II–IV range, whereas the hazard model is oriented toward forecasts at higher ground‐motion intensities, usually above about MMI IV. Nevertheless, the study demonstrates some of the issues that arise in making these comparisons, thereby informing future efforts to ground‐truth and improve hazard modeling for induced‐seismicity applications.

  5. Radio Continuum Surveys with Square Kilometre Array Pathfinders

    NASA Astrophysics Data System (ADS)

    Norris, Ray P.; Afonso, J.; Bacon, D.; Beck, Rainer; Bell, Martin; Beswick, R. J.; Best, Philip; Bhatnagar, Sanjay; Bonafede, Annalisa; Brunetti, Gianfranco; Budavári, Tamás; Cassano, Rossella; Condon, J. J.; Cress, Catherine; Dabbech, Arwa; Feain, I.; Fender, Rob; Ferrari, Chiara; Gaensler, B. M.; Giovannini, G.; Haverkorn, Marijke; Heald, George; Van der Heyden, Kurt; Hopkins, A. M.; Jarvis, M.; Johnston-Hollitt, Melanie; Kothes, Roland; Van Langevelde, Huib; Lazio, Joseph; Mao, Minnie Y.; Martínez-Sansigre, Alejo; Mary, David; Mcalpine, Kim; Middelberg, E.; Murphy, Eric; Padovani, P.; Paragi, Zsolt; Prandoni, I.; Raccanelli, A.; Rigby, Emma; Roseboom, I. G.; Röttgering, H.; Sabater, Jose; Salvato, Mara; Scaife, Anna M. M.; Schilizzi, Richard; Seymour, N.; Smith, Dan J. B.; Umana, Grazia; Zhao, G.-B.; Zinn, Peter-Christian

    2013-03-01

    In the lead-up to the Square Kilometre Array (SKA) project, several next-generation radio telescopes and upgrades are already being built around the world. These include APERTIF (The Netherlands), ASKAP (Australia), e-MERLIN (UK), VLA (USA), e-EVN (based in Europe), LOFAR (The Netherlands), MeerKAT (South Africa), and the Murchison Widefield Array. Each of these new instruments has different strengths, and coordination of surveys between them can help maximise the science from each of them. A radio continuum survey is being planned on each of them with the primary science objective of understanding the formation and evolution of galaxies over cosmic time, and the cosmological parameters and large-scale structures which drive it. In pursuit of this objective, the different teams are developing a variety of new techniques, and refining existing ones. To achieve these exciting scientific goals, many technical challenges must be addressed by the survey instruments. Given the limited resources of the global radio-astronomical community, it is essential that we pool our skills and knowledge. We do not have sufficient resources to enjoy the luxury of re-inventing wheels. We face significant challenges in calibration, imaging, source extraction and measurement, classification and cross-identification, redshift determination, stacking, and data-intensive research. As these instruments extend the observational parameters, we will face further unexpected challenges in calibration, imaging, and interpretation. If we are to realise the full scientific potential of these expensive instruments, it is essential that we devote enough resources and careful study to understanding the instrumental effects and how they will affect the data. We have established an SKA Radio Continuum Survey working group, whose prime role is to maximise science from these instruments by ensuring we share resources and expertise across the projects. Here we describe these projects, their science goals

  6. Regional High School Senior Survey.

    ERIC Educational Resources Information Center

    Day, Philip R., Jr.

    In order to identify the educational needs and aspirations of graduating high school seniors in the service region of the University of Maine at Augusta, a survey instrument was designed and administered to 1,950 seniors at 19 institutions. In all, 1,744 completed surveys were returned, a 92 percent response rate. The data are sub-grouped into…

  7. Quantitative Hyperspectral Reflectance Imaging

    PubMed Central

    Klein, Marvin E.; Aalderink, Bernard J.; Padoan, Roberto; de Bruin, Gerrit; Steemers, Ted A.G.

    2008-01-01

    Hyperspectral imaging is a non-destructive optical analysis technique that can for instance be used to obtain information from cultural heritage objects unavailable with conventional colour or multi-spectral photography. This technique can be used to distinguish and recognize materials, to enhance the visibility of faint or obscured features, to detect signs of degradation and study the effect of environmental conditions on the object. We describe the basic concept, working principles, construction and performance of a laboratory instrument specifically developed for the analysis of historical documents. The instrument measures calibrated spectral reflectance images at 70 wavelengths ranging from 365 to 1100 nm (near-ultraviolet, visible and near-infrared). By using a wavelength tunable narrow-bandwidth light-source, the light energy used to illuminate the measured object is minimal, so that any light-induced degradation can be excluded. Basic analysis of the hyperspectral data includes a qualitative comparison of the spectral images and the extraction of quantitative data such as mean spectral reflectance curves and statistical information from user-defined regions-of-interest. More sophisticated mathematical feature extraction and classification techniques can be used to map areas on the document, where different types of ink had been applied or where one ink shows various degrees of degradation. The developed quantitative hyperspectral imager is currently in use by the Nationaal Archief (National Archives of The Netherlands) to study degradation effects of artificial samples and original documents, exposed in their permanent exhibition area or stored in their deposit rooms. PMID:27873831

  8. ED School Climate Surveys (EDSCLS) National Benchmark Study 2016. Appendix D. EDSCLS Pilot Test 2015 Report

    ERIC Educational Resources Information Center

    National Center for Education Statistics, 2015

    2015-01-01

    The ED School Climate Surveys (EDSCLS) are a suite of survey instruments being developed for schools, school districts, and states by the U.S. Department of Education's National Center for Education Statistics (NCES). Through the EDSCLS, schools nationwide will have access to survey instruments and a survey platform that will allow for the…

  9. The Development of a Tactical-Level Full Range Leadership Measurement Instrument

    DTIC Science & Technology

    2010-03-01

    full range leadership theory has become established as the predominant and most widely researched theory on leadership . The most commonly used survey...instrument to assess full range leadership theory is the Multifactor Leadership Questionnaire, originally developed by Bass in 1985. Although much...existing literature to develop a new full range leadership theory measurement instrument that effectively targets low- to mid-level supervisors, or

  10. Recent developments in hydrologic instrumentation

    USGS Publications Warehouse

    Latkovich, Vito J.; Futrell, James C.; Kane, Douglas L.

    1986-01-01

    The programs of the U.S. Geological Survey require instrumentation for collecting and monitoring hydrologic data in cold regions. The availability of space-age materials and implementation of modern electronics and mechanics is making possible the recent developments of hydrologic instrumentation, especially in the area of measuring streamflow under ice cover. Material developments include: synthetic-fiber sounding and tag lines; polymer (plastic) sheaves, pulleys, and sampler components; and polymer (plastic) current-meter bucket wheels. Electronic and mechanical developments include: a current-meter digitizer; a fiber-optic closure system for current-meters; non-contact water-level sensors; an adaptable hydrologic data acquisition system; a minimum data recorder; an ice rod; an ice foot; a handled sediment sampler; a light weight ice auger with improved cutter head and blades; and an ice chisel.

  11. Improved accuracy in quantitative laser-induced breakdown spectroscopy using sub-models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, Ryan B.; Clegg, Samuel M.; Frydenvang, Jens

    We report that accurate quantitative analysis of diverse geologic materials is one of the primary challenges faced by the Laser-Induced Breakdown Spectroscopy (LIBS)-based ChemCam instrument on the Mars Science Laboratory (MSL) rover. The SuperCam instrument on the Mars 2020 rover, as well as other LIBS instruments developed for geochemical analysis on Earth or other planets, will face the same challenge. Consequently, part of the ChemCam science team has focused on the development of improved multivariate analysis calibrations methods. Developing a single regression model capable of accurately determining the composition of very different target materials is difficult because the response ofmore » an element’s emission lines in LIBS spectra can vary with the concentration of other elements. We demonstrate a conceptually simple “submodel” method for improving the accuracy of quantitative LIBS analysis of diverse target materials. The method is based on training several regression models on sets of targets with limited composition ranges and then “blending” these “sub-models” into a single final result. Tests of the sub-model method show improvement in test set root mean squared error of prediction (RMSEP) for almost all cases. Lastly, the sub-model method, using partial least squares regression (PLS), is being used as part of the current ChemCam quantitative calibration, but the sub-model method is applicable to any multivariate regression method and may yield similar improvements.« less

  12. Improved accuracy in quantitative laser-induced breakdown spectroscopy using sub-models

    DOE PAGES

    Anderson, Ryan B.; Clegg, Samuel M.; Frydenvang, Jens; ...

    2016-12-15

    We report that accurate quantitative analysis of diverse geologic materials is one of the primary challenges faced by the Laser-Induced Breakdown Spectroscopy (LIBS)-based ChemCam instrument on the Mars Science Laboratory (MSL) rover. The SuperCam instrument on the Mars 2020 rover, as well as other LIBS instruments developed for geochemical analysis on Earth or other planets, will face the same challenge. Consequently, part of the ChemCam science team has focused on the development of improved multivariate analysis calibrations methods. Developing a single regression model capable of accurately determining the composition of very different target materials is difficult because the response ofmore » an element’s emission lines in LIBS spectra can vary with the concentration of other elements. We demonstrate a conceptually simple “submodel” method for improving the accuracy of quantitative LIBS analysis of diverse target materials. The method is based on training several regression models on sets of targets with limited composition ranges and then “blending” these “sub-models” into a single final result. Tests of the sub-model method show improvement in test set root mean squared error of prediction (RMSEP) for almost all cases. Lastly, the sub-model method, using partial least squares regression (PLS), is being used as part of the current ChemCam quantitative calibration, but the sub-model method is applicable to any multivariate regression method and may yield similar improvements.« less

  13. Landsat's TIRS Instrument

    NASA Image and Video Library

    2017-12-08

    The Thermal Infrared Sensor (TIRS) will fly on the next Landsat satellite, the Landsat Data Continuity Mission (LDCM). The right side of the instrument is what's called the 'nadir side,' that's the side that points toward Earth when the instrument is in space. The black circle visible on the right side is where the optics for the instrument are located. In that area are the lens and the detectors. The white area is a radiator that radiates heat to keep the telescope and the detector cool. The black hole on the white area on the left is what the satellite operators point to deep space when they calibrate the instrument to the cold temperatures of space. TIRS was built on an accelerated schedule at NASA's Goddard Space Flight Center, Greenbelt, Md. and will now be integrated into the LDCM spacecraft at Orbital Science Corp. in Gilbert, Ariz. The Landsat Program is a series of Earth observing satellite missions jointly managed by NASA and the U.S. Geological Survey. Landsat satellites have been consistently gathering data about our planet since 1972. They continue to improve and expand this unparalleled record of Earth's changing landscapes for the benefit of all. For more information on Landsat, visit: www.nasa.gov/landsat Credit: NASA/GSFC/Rebecca Roth NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  14. Establishing Content Validity for a Literacy Coach Performance Appraisal Instrument

    ERIC Educational Resources Information Center

    Lane, Mae; Robbins, Mary; Price, Debra

    2013-01-01

    This study's purpose was to determine whether or not the Literacy Coach Appraisal Instrument developed for use in evaluating literacy coaches had content validity. The study, a fully mixed concurrent equal status design conducted from a pragmatist philosophy, collected qualitative and quantitative data from literacy experts about the elements of…

  15. Developing an oropharyngeal cancer (OPC) knowledge and behaviors survey.

    PubMed

    Dodd, Virginia J; Riley Iii, Joseph L; Logan, Henrietta L

    2012-09-01

    To use the community participation research model to (1) develop a survey assessing knowledge about mouth and throat cancer and (2) field test and establish test-retest reliability with newly developed instrument. Cognitive interviews with primarily rural African American adults to assess their perception and interpretation of survey items. Test-retest reliability was established with a racially diverse rural population. Test-retest reliabilities ranged from .79 to .40 for screening awareness and .74 to .19 for knowledge. Coefficients increased for composite scores. Community participation methodology provided a culturally appropriate survey instrument that demonstrated acceptable levels of reliability.

  16. 39 CFR 3055.92 - Customer Experience Measurement Surveys.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 39 Postal Service 1 2012-07-01 2012-07-01 false Customer Experience Measurement Surveys. 3055.92... SATISFACTION REPORTING Reporting of Customer Satisfaction § 3055.92 Customer Experience Measurement Surveys. (a... instrument including: (1) A description of the customer type targeted by the survey; (2) The number of...

  17. 39 CFR 3055.92 - Customer Experience Measurement Surveys.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 39 Postal Service 1 2011-07-01 2011-07-01 false Customer Experience Measurement Surveys. 3055.92... SATISFACTION REPORTING Reporting of Customer Satisfaction § 3055.92 Customer Experience Measurement Surveys. (a... instrument including: (1) A description of the customer type targeted by the survey; (2) The number of...

  18. 39 CFR 3055.92 - Customer Experience Measurement Surveys.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 39 Postal Service 1 2013-07-01 2013-07-01 false Customer Experience Measurement Surveys. 3055.92... SATISFACTION REPORTING Reporting of Customer Satisfaction § 3055.92 Customer Experience Measurement Surveys. (a... instrument including: (1) A description of the customer type targeted by the survey; (2) The number of...

  19. 39 CFR 3055.92 - Customer Experience Measurement Surveys.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 39 Postal Service 1 2014-07-01 2014-07-01 false Customer Experience Measurement Surveys. 3055.92... SATISFACTION REPORTING Reporting of Customer Satisfaction § 3055.92 Customer Experience Measurement Surveys. (a... instrument including: (1) A description of the customer type targeted by the survey; (2) The number of...

  20. Handbook of Research on Electronic Surveys and Measurements

    ERIC Educational Resources Information Center

    Reynolds, Rodney, Ed.; Woods, Robert, Ed.; Baker, Jason, Ed.

    2007-01-01

    The "Handbook of Research on Electronic Surveys and Measurements" is the comprehensive reference source for innovative knowledge on electronic surveys. This commanding handbook of research provides complete coverage of the challenges associated with the use of the Internet to develop online surveys, administer Web-based instruments, and conduct…

  1. Project MAGNET High-level Vector Survey Data Reduction

    NASA Technical Reports Server (NTRS)

    Coleman, Rachel J.

    1992-01-01

    Since 1951, the U.S. Navy, under its Project MAGNET program, has been continuously collecting vector aeromagnetic survey data to support the U.S. Defense Mapping Agency's world magnetic and charting program. During this forty-year period, a variety of survey platforms and instrumentation configurations have been used. The current Project MAGNET survey platform is a Navy Orion RP-3D aircraft which has been specially modified and specially equipped with a redundant suite of navigational positioning, attitude, and magnetic sensors. A review of the survey data collection procedures and calibration and editing techniques applied to the data generated by this suite of instrumentation will be presented. Among the topics covered will be the determination of its parameters from the low-level calibration maneuvers flown over geomagnetic observatories.

  2. Building a Case for Conducting Technology Surveys On-Line.

    ERIC Educational Resources Information Center

    Denton, Jon J.; Strader, Arlen

    A Technology in Texas Public Schools 1998 Survey instrument was integrated into a Web-based response system enabling the instrument to be accessed, completed, submitted, and instantaneously analyzed over the Internet. A mark-sense or optical scan paper version of the instrument was also developed for mail-out distribution to each school district…

  3. Institutional Conservation Program Evaluation Project: Results of hospital survey pretest

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Collins, N.E.; Hatfield, B.K.; Kier, P.H.

    As part of a study of energy conservation efforts in schools and hospitals and an evaluation of the Institutional Conservation Program sponsored by the US Department of Energy (DOE), teams from Argonne National Laboratory, Lawrence Berkeley Laboratory, and DOE visited 15 hospitals to pretest a survey instrument (in the form of a 10-page questionnaire and a list of definitions) that will be sent to 1800 hospitals to solicit information on their energy consumption, energy conservation activities, and decision-making processes. The pretest had several purposes, including identification of problems in the survey instrument's format and in the wording of instructions andmore » questions. This report covers all aspects of the pretest. Characteristics of the hospitals and of the interviewees are discussed. Pretest procedures are described and responses to some of the survey questions are provided. Narrative summaries of selected interviews, containing informative anecdotes, are included in an appendix, as are technology transfer ideas and the final version of the survey instrument.« less

  4. Development and application of an instrument for analysis of bone structure on radiographs.

    PubMed

    Xu, S; Liu, S; Bao, K

    1997-01-01

    An instrument used for quantitative assessment of trabecular structure of radius on radiograph including trabecular number and trabecular width was developed using a microdensitometer and a single-chip microcomputer. The device is characterized by its high sensitivity, good reproducibility, convenience and economy. The results obtained with the instrument were significantly correlated to actual bone mineral content. This device can be used for the diagnosis of osteoporosis, fluorosis, rickets and bone damages caused by cadmium.

  5. The implementation of quantitative electromyographic neuromuscular monitoring in an academic anesthesia department.

    PubMed

    Todd, Michael M; Hindman, Bradley J; King, Brian J

    2014-08-01

    Although experts agree on the importance of quantitative neuromuscular blockade monitoring, particularly for managing reversal, such monitoring is not in widespread use. We describe the processes and results of our departmental experience with the introduction of such quantitative monitoring. In mid-2010, the senior authors became concerned about the management of nondepolarizing neuromuscular blockers (NMB) by providers within the department, based on personal observations and on a review of a departmental quality assurance/adverse event database. This review indicated the occurrence of 2 to 4 reintubations/year in the postanesthesia care unit (PACU) that were deemed to be probably or possibly related to inadequate reversal. In response, quantitative blockade equipment (Datex-Omeda ElectroSensor™ EMG system) was installed in all our main operating rooms in January 2011. This introduction was accompanied by an extensive educational effort. Adoption of the system was slow; by mid-2011, the quantitative system was being used in <50% of cases involving nondepolarizing relaxants and adverse NMB-related events continued to occur. Therefore, starting in August 2011 and extending over the next 2 years, we performed a series of 5 separate sampling surveys in the PACU in which train-of-four (TOF) ratios were recorded in 409 tracheally extubated adult patients who had received nondepolarizing NMB (almost exclusively rocuronium) as well as in 73 patients who had not received any nondepolarizing NMB. After each survey, the results were presented to the entire department, along with discussions of individual cases, reviews of the recent literature regarding quantitative monitoring and further education regarding the use of the quantitative system. In the initial (August 2011) PACU survey of 96 patients receiving nondepolarizing NMBs, 31% had a TOF ratio of ≤0.9, 17% had a ratio of ≤0.8, and 4 patients (4%) had ratios of ≤0.5. A record review showed that the quantitative

  6. Assessment of classification instruments designed to detect alcohol abuse

    DOT National Transportation Integrated Search

    1988-12-01

    The report summarizes an effort to identify and evaluate instruments currently in use to assess substance abuse problems in driving while impaired (DWI) offenders. The results of a national survey of DWI assessment practices in the United States are ...

  7. [Development of an evaluation instrument for service quality in nursing homes].

    PubMed

    Lee, Jia; Ji, Eun Sun

    2011-08-01

    The purposes of this study were to identify the factors influencing service quality in nursing homes, and to develop an evaluation instrument for service quality. A three-phase process was employed for the study. 1) The important factors to evaluate the service quality in nursing homes were identified through a literature review, panel discussion and focus group interview, 2) the evaluation instrument was developed, and 3) validity and reliability of the study instrument were tested by factor analysis, Pearson correlation coefficient, Cronbach's α and Cohen's Kappa. Factor analysis showed that the factors influencing service quality in nursing homes were healthcare, diet/assistance, therapy, environment and staff. To improve objectivity of the instrument, quantitative as well as qualitative evaluation approaches were adopted. The study instrument was developed with 30 items and showed acceptable construct validity. The criterion-related validity was a Pearson correlation coefficient of .85 in 151 care facilities. The internal consistency was Cronbach's α=.95. The instrument has acceptable validity and a high degree of reliability. Staff in nursing homes can continuously improve and manage their services using the results of the evaluation instrument.

  8. [Survey of pain after ambulatory surgery: An internet-based instrument].

    PubMed

    Schwarze, C; Zenz, D; Orlowski, O; Wempe, C; Van Aken, H; Zahn, P; Maier, C; Pogatzki-Zahn, E M

    2016-04-01

    Pain after surgery continues to be undermanaged. Studies and initiatives aiming to improve the management of postoperative pain are growing; however, most studies focus on inpatients and pain on the first day after surgery. The management of postoperative pain after ambulatory surgery and for several days thereafter is not yet a major focus. One reason is the low return rate of the questionnaires in the ambulatory sector. This article reports the development and feasibility of a web-based electronic data collection system to examine pain and pain-related outcome on predefined postoperative days after ambulatory surgery. In this prospective pilot study 127 patients scheduled for ambulatory surgery were asked to participate in a survey to evaluate aspects related to pain after ambulatory surgery. The data survey was divided in (1) a preoperative, intraoperative and postoperative part and (2) a postoperative internet-based electronic questionnaire which was sent via e-mail link to the patient on days 1, 3 and 7 after surgery. A software was developed using a PHP-based platform to send e-mails and retrieve the data after web-based entries via a local browser. Feasibility, internet-based hitches and compliance were assessed by an additional telephone call after day 7. A total of 100 patients (50 female) between 18 and 71 years (mean 39.1 ± 12.7 years) were included in the pilot study. Return rates of the electronic questionnaires were 86% (days 3 and 7) and 91% (day 1 after surgery). All 3 electronic questionnaires were answered by 82% of patients. Aspects influencing the return rate of questionnaires were work status but not age, gender, education level and preoperative pain. Telephone interviews were performed with 81 patients and revealed high operability of the internet-based survey without any major problems. The user-friendly feasibility and operability of this internet-based electronic data survey system explain the high compliance and return rate of

  9. Note: Measuring instrument of singlet oxygen quantum yield in photodynamic effects

    NASA Astrophysics Data System (ADS)

    Li, Zhongwei; Zhang, Pengwei; Zang, Lixin; Qin, Feng; Zhang, Zhiguo; Zhang, Hongli

    2017-06-01

    Using diphenylisobenzofuran (C20H14O) as a singlet oxygen (1O2) reporter, a comparison method, which can be used to measure the singlet oxygen quantum yield (ΦΔ) of the photosensitizer quantitatively, is presented in this paper. Based on this method, an automatic measuring instrument of singlet oxygen quantum yield is developed. The singlet oxygen quantum yield of the photosensitizer hermimether and aloe-emodin is measured. It is found that the measuring results are identical to the existing ones, which verifies the validity of the measuring instrument.

  10. EVALUATION OF RAPID DNA EXTRACTION PROCEDURES FOR THE QUANTITATIVE DETECTION OF FUNGAL CELLS USING REAL TIME PCR ANALYSIS

    EPA Science Inventory

    The ease and rapidity of quantitative DNA sequence detection by real-time PCR instruments promises to make their use increasingly common for the microbial analysis many different types of environmental samples. To fully exploit the capabilities of these instruments, correspondin...

  11. Trace Gas Retrievals from the GeoTASO Aircraft Instrument

    NASA Astrophysics Data System (ADS)

    Nowlan, C. R.; Liu, X.; Leitch, J. W.; Liu, C.; Gonzalez Abad, G.; Chance, K.; Cole, J.; Delker, T.; Good, W. S.; Murcray, F.; Ruppert, L.; Soo, D.; Loughner, C.; Follette-Cook, M. B.; Janz, S. J.; Kowalewski, M. G.; Pickering, K. E.; Zoogman, P.; Al-Saadi, J. A.

    2015-12-01

    The Geostationary Trace gas and Aerosol Sensor Optimization (GeoTASO) instrument is a passive remote sensing instrument capable of making 2-D measurements of trace gases and aerosols from aircraft. The instrument measures backscattered UV and visible radiation, allowing the retrieval of trace gas amounts below the aircraft at horizontal resolutions on the order of 250 m x 250 m. GeoTASO was originally developed under NASA's Instrument Incubator Program as a test-bed instrument for the Geostationary Coastal and Air Pollution Events (GEO-CAPE) decadal survey mission, and is now also part of risk reduction for the upcoming Tropospheric Emissions: Monitoring of Pollution (TEMPO) and Geostationary Environment Monitoring Spectrometer (GEMS) geostationary satellite missions. We present spatially resolved observations of ozone, nitrogen dioxide, formaldehyde and sulfur dioxide over urban areas and power plants from flights during the DISCOVER-AQ field campaigns in Texas and Colorado, as well as comparisons with observations made by ground-based Pandora spectrometers, in situ monitoring instruments and other aircraft instruments deployed during these campaigns. These measurements at various times of day are providing a very useful data set for testing and improving TEMPO and GEMS retrieval algorithms, as well as demonstrating prototype validation strategies.

  12. Barriers to Accessing Emergency Medical Services in Accra, Ghana: Development of a Survey Instrument and Initial Application in Ghana

    PubMed Central

    Mould-Millman, Nee-Kofi; Rominski, Sarah D; Bogus, Joshua; Ginde, Adit A; Zakariah, Ahmed N; Boatemaah, Christiana A; Yancey, Arthur H; Akoriyea, Samuel Kaba; Campbell, Thomas B

    2015-01-01

    Background: Emergency medical services (EMS) systems provide professional prehospital emergency medical care and transportation to help improve outcomes from emergency conditions. Ghana’s national ambulance service has relatively low public utilization in comparison with the large burden of acute disease. Methods: A survey instrument was developed using Pechansky and Thomas’s model of access covering 5 dimensions of availability, accessibility, accommodation, affordability, and acceptability. The instrument was used in a cross-sectional survey in 2013 in Accra, Ghana; eligible participants were those 18 years and older who spoke English, French, or Twi. Although the analysis was mainly descriptive, logistic regression was used to identify factors associated with reported intention to call for an ambulance in the case of a medical emergency. Results: 468 participants completed surveys, with a response rate of 78.4%. Few (4.5%) respondents had ever used an ambulance in prior emergency situations. A substantial proportion (43.8%) knew about the public access medical emergency telephone number, but of those only 37.1% knew it was a toll-free call. Most (54.7%) respondents believed EMTs offered high-quality care, but 78.0% believed taxis were faster than ambulances and 69.2% thought the number of ambulances in Accra insufficient. Many (23.4%) thought using ambulances to transport corpses would be appropriate. In two hypothetical emergency scenarios, respondents most commonly reported taxis as the preferred transportation (63.6% if a family member were burned in a house fire, 64.7% if a pedestrian were struck by a vehicle). About 1 in 5 respondents said they would call an ambulance in either scenario (20.7% if a family member were burned in a house fire, 23.3% if a pedestrian were struck by a vehicle) while 15.5% and 10.2%, respectively, would use any available vehicle. Those aged 18–35 years were more likely than older respondents to prefer an ambulance (odds

  13. Barriers to Accessing Emergency Medical Services in Accra, Ghana: Development of a Survey Instrument and Initial Application in Ghana.

    PubMed

    Mould-Millman, Nee-Kofi; Rominski, Sarah D; Bogus, Joshua; Ginde, Adit A; Zakariah, Ahmed N; Boatemaah, Christiana A; Yancey, Arthur H; Akoriyea, Samuel Kaba; Campbell, Thomas B

    2015-12-01

    Emergency medical services (EMS) systems provide professional prehospital emergency medical care and transportation to help improve outcomes from emergency conditions. Ghana's national ambulance service has relatively low public utilization in comparison with the large burden of acute disease. A survey instrument was developed using Pechansky and Thomas's model of access covering 5 dimensions of availability, accessibility, accommodation, affordability, and acceptability. The instrument was used in a cross-sectional survey in 2013 in Accra, Ghana; eligible participants were those 18 years and older who spoke English, French, or Twi. Although the analysis was mainly descriptive, logistic regression was used to identify factors associated with reported intention to call for an ambulance in the case of a medical emergency. 468 participants completed surveys, with a response rate of 78.4%. Few (4.5%) respondents had ever used an ambulance in prior emergency situations. A substantial proportion (43.8%) knew about the public access medical emergency telephone number, but of those only 37.1% knew it was a toll-free call. Most (54.7%) respondents believed EMTs offered high-quality care, but 78.0% believed taxis were faster than ambulances and 69.2% thought the number of ambulances in Accra insufficient. Many (23.4%) thought using ambulances to transport corpses would be appropriate. In two hypothetical emergency scenarios, respondents most commonly reported taxis as the preferred transportation (63.6% if a family member were burned in a house fire, 64.7% if a pedestrian were struck by a vehicle). About 1 in 5 respondents said they would call an ambulance in either scenario (20.7% if a family member were burned in a house fire, 23.3% if a pedestrian were struck by a vehicle) while 15.5% and 10.2%, respectively, would use any available vehicle. Those aged 18-35 years were more likely than older respondents to prefer an ambulance (odds ratio [OR], 2.27; confidence interval

  14. The Survey Questionnaire

    ERIC Educational Resources Information Center

    Ritter, Lois A. Ed.; Sue, Valerie M., Ed.

    2007-01-01

    Internet-based surveys are still relatively new, and researchers are just beginning to articulate best practices for questionnaire design. Online questionnaire design has generally been guided by the principles applying to other self-administered instruments, such as paper-based questionnaires. Web-based questionnaires, however, have the potential…

  15. Patient-specific instruments: industry's innovation with a surgeon's interest.

    PubMed

    Thienpont, Emmanuel; Bellemans, Johan; Delport, Hendrik; Van Overschelde, Philippe; Stuyts, Bart; Brabants, Karl; Victor, Jan

    2013-10-01

    The aim of this study was (1) to survey the orthopaedic companies about the volume of patient-specific instruments (PSI) used in Europe and worldwide; (2) to survey a group of knee arthroplasty surgeons on their acceptance of PSI and finally; (3) to survey a medico-legal expert on PSI-related issues. Seven orthopaedic implant manufacturers were contacted to obtain their sales figures (in volume) of PSI in Europe and worldwide for the 2011 and 2012 period. During the Open Meeting of the Belgian Knee Society, a survey by a direct voting system was submitted to a selection of knee surgeons. Finally, a number of medico-legal 'PSI-related' questions were submitted to an adult reconstruction surgeon/legal expert. The total volume, for all contacted companies, of PSI in Europe for 2012 was 17,515 total knee arthroplasty (TKA) and 82,556 TKA worldwide. Biomet (Warsaw, USA) was the number one in volume, both in Europe as worldwide with their Signature system. Biomet represented 27 % of the market share in PSI worldwide. Stryker preferred not to reply to the survey because of the FDA class 1 recall on ShapeMatch cutting guides. Eighty per cent of the Belgian knee surgeons expressed a great interest in PSI and especially, for 58 % of them, if it would increase their surgical accuracy. They valued it even more in unicompartmental arthroplasty, and 55 % was ready to use single-use instruments. Surprisingly, 47 % of surgeons thought it was the company's responsibility if something goes wrong with a PSI-assisted case. The medico-legal expert concluded that PSI is a complex process that exposes surgeons to new risks in case of failure and stated that companies should not produce surgical guides without validation of the planning by the surgeon. Patient-specific instruments is of great interest if it can proof to increase the surgical accuracy in knee arthroplasty to the level surgeons are expecting and if in the same time it would make the surgical process more efficient. V.

  16. Advanced Technologies and Instrumentation at the National Science Foundation

    NASA Astrophysics Data System (ADS)

    Kurczynski, Peter; Neff, James E.

    2018-01-01

    Over its more than thirty-year history, the Advanced Technologies and Instrumentation (ATI) program within the Division of Astronomical Sciences has provided grants to support the development and deployment of detectors and instrumentation for ground-based astronomy. This program has enabled scientific advances in diverse fields from solar physics to exoplanets to cosmology. ATI has provided instrumentation for both small and large observatories from radio through visible wavebands. It has played a role in the early development of major initiatives such as the Large Synoptic Survey Telescope. Technology development for astronomy unfolds over a longer period than the lifetime of a single grant. This review will consider ATI from an historical perspective to assess its impact on astronomy.

  17. Greek Alcohol Survey: Results and Analysis.

    ERIC Educational Resources Information Center

    Jensen, Wesley; And Others

    Alcohol use among 458 members of Greek fraternities and sororities at the University of North Dakota was surveyed. The survey instrument, which was an adaptation of a questionnaire developed by Michael A. Looney, was directed to frequency of use, amounts consumed, type of beverage, attitudes, and demographic information. It was found that…

  18. Instrument pre-development activities for FLEX

    NASA Astrophysics Data System (ADS)

    Pettinato, L.; Fossati, E.; Coppo, P. M.; Taiti, A.; Labate, D.; Capanni, A.; Taccola, M.; Bézy, J. L.; Francois, M.; Meynart, R.; Erdmann, L.; Triebel, P.

    2017-09-01

    The FLuorescence Imaging Spectrometer (FLORIS) is the payload of the FLuorescence Explorer Mission (FLEX) of the European Space Agency. The mission objective is to perform quantitative measurements of the solar induced vegetation fluorescence to monitor photosynthetic activity. FLORIS works in a push-broom configuration and it is designed to acquire data in the 500-780 nm spectral range, with a sampling of 0.1 nm in the oxygen bands (759-769 nm and 686- 697 nm) and 0.5-2.0 nm in the red edge, chlorophyll absorption and Photochemical Reflectance Index bands. FLEX will fly in formation with Sentinel-3 to benefit of the measurements made by the Sentinel-3 instruments OLCI and SLSTR, particularly for cloud screening, proper characterization of the atmospheric state and determination of the surface temperature. The instrument concept is based on a common telescope and two modified Offner spectrometers with reflective concave gratings both for the High Resolution (HR) and Low Resolution (LR) spectrometers. In the frame of the instrument pre-development Leonardo Company (I) has built and tested an elegant breadboard of the instrument consisting of the telescope and the HR spectrometer. The development of the LR spectrometer is in charge of OHB System AG (D) and is currently in the manufacturing phase. The main objectives of the activity are: anticipate the development of the instrument and provide early risk retirement of critical components, evaluate the system performances such as imaging quality parameters, straylight, ghost, polarization sensitivity and environmental influences, verify the adequacy of critical tests such as spectral characterization and straylight, define and optimize instrument alignment procedures. Following a brief overview of the FLEX mission, the paper will cover the design and the development of the optics breadboard with emphasis on the results obtained during the tests and the lessons learned for the flight unit.

  19. Analysis of small-angle X-ray scattering data in the presence of significant instrumental smearing

    PubMed Central

    Bergenholtz, Johan; Ulama, Jeanette; Zackrisson Oskolkova, Malin

    2016-01-01

    A laboratory-scale small-angle X-ray scattering instrument with pinhole collimation has been used to assess smearing effects due to instrumental resolution. A new, numerically efficient method to smear ideal model intensities is developed and presented. It allows for directly using measured profiles of isotropic but otherwise arbitrary beams in smearing calculations. Samples of low-polydispersity polymer spheres have been used to show that scattering data can in this way be quantitatively modeled even when there is substantial distortion due to instrumental resolution. PMID:26937235

  20. Outcomes for implementation science: an enhanced systematic review of instruments using evidence-based rating criteria.

    PubMed

    Lewis, Cara C; Fischer, Sarah; Weiner, Bryan J; Stanick, Cameo; Kim, Mimi; Martinez, Ruben G

    2015-11-04

    High-quality measurement is critical to advancing knowledge in any field. New fields, such as implementation science, are often beset with measurement gaps and poor quality instruments, a weakness that can be more easily addressed in light of systematic review findings. Although several reviews of quantitative instruments used in implementation science have been published, no studies have focused on instruments that measure implementation outcomes. Proctor and colleagues established a core set of implementation outcomes including: acceptability, adoption, appropriateness, cost, feasibility, fidelity, penetration, sustainability (Adm Policy Ment Health Ment Health Serv Res 36:24-34, 2009). The Society for Implementation Research Collaboration (SIRC) Instrument Review Project employed an enhanced systematic review methodology (Implement Sci 2: 2015) to identify quantitative instruments of implementation outcomes relevant to mental or behavioral health settings. Full details of the enhanced systematic review methodology are available (Implement Sci 2: 2015). To increase the feasibility of the review, and consistent with the scope of SIRC, only instruments that were applicable to mental or behavioral health were included. The review, synthesis, and evaluation included the following: (1) a search protocol for the literature review of constructs; (2) the literature review of instruments using Web of Science and PsycINFO; and (3) data extraction and instrument quality ratings to inform knowledge synthesis. Our evidence-based assessment rating criteria quantified fundamental psychometric properties as well as a crude measure of usability. Two independent raters applied the evidence-based assessment rating criteria to each instrument to generate a quality profile. We identified 104 instruments across eight constructs, with nearly half (n = 50) assessing acceptability and 19 identified for adoption, with all other implementation outcomes revealing fewer than 10

  1. Acoustical Surveys Of Methane Plumes By Using The Quantitative Echo Sounder In The Eastern Margin Of The Sea of Japan

    NASA Astrophysics Data System (ADS)

    Aoyama, C.; Matsumoto, R.; Okuda, Y.; Ishida, Y.; Hiruta, A.; Sunamura, M.; Numanami, H.; Tomaru, H.; Snyder, G.; Komatsubara, J.; Takeuchi, R.; Hiromatsu, M.; Aoyama, D.; Koike, Y.; Takeda, S.; Hayashi, T.; Hamada, H.

    2004-12-01

    The reseach and trainning/V, Umitaka-maru sailed to the methane seep area on a small ridge in the eastern margin of the Sea of Japan on July to August 2004 to survey the ocean floor gas hydrate and related acoustic signatures of methane plumes by using a quantitative echo sounder. Detailed bathymetric profiles have revealed a number of mounds, pockmarks and collapse structures within 3km x 4km on the ridge at the water depth of 910m to 980m. We mapped minutely methane plumes by using a quantitative echo sounder with positioning data from GPS. We also measured averaged echo intensity from the methane plumes both in every 100m range and every one minute by the echo integrator. We obtained the following results from the present echo-sounder survey. 1) We checked 36 plumes on echogram, ranging 100m to 200m in diameter and 600m to 700m in height, reaching up to 200m to 300m below sea level. 2) We measured the averaged volume backscattering strength (SV) of each methane plume. The strongest SV, -45dB, of the plumes was stronger than SV of fish school. 3) Averaged SV tend to show the highest values around the middle of plumes, whereas the SVs are relatively low at the bottom and the top of plumes. 4) Some of the plumes were observed to show daily fluctuation in height and width. 5) We recovered several fist-sized chunks of methane hydrate by piston coring at the area where we observed methane plumes. As a following up project, we are planning to measure SV of methane bubbles and methane hydrate floating in water columns through an experimental studies in a large water tanks.

  2. Gyroscopic Instruments for Instrument Flying

    NASA Technical Reports Server (NTRS)

    Brombacher, W G; Trent, W C

    1938-01-01

    The gyroscopic instruments commonly used in instrument flying in the United States are the turn indicator, the directional gyro, the gyromagnetic compass, the gyroscopic horizon, and the automatic pilot. These instruments are described. Performance data and the method of testing in the laboratory are given for the turn indicator, the directional gyro, and the gyroscopic horizon. Apparatus for driving the instruments is discussed.

  3. Quality of integrated chronic care measured by patient survey: identification, selection and application of most appropriate instruments

    PubMed Central

    Vrijhoef, Hubertus J. M.; Berbee, Rieneke; Wagner, Edward H.; Steuten, Lotte M. G.

    2009-01-01

    Abstract Objective  To identify the most appropriate generic instrument to measure experience and/or satisfaction of people receiving integrated chronic care. Background  Health care is becoming more user‐centred and, as a result, the experience of users of care and evaluation of their experience and/or satisfaction is taken more seriously. It is unclear to what extent existing instruments are appropriate in measuring the experience and/or satisfaction of people using integrated chronic care. Methods  Instruments were identified by means of a systematic literature review. Appropriateness of instruments was analysed on seven criteria. The two most promising instruments were translated into Dutch, if necessary, and administered to a convenience sample of 109 people with a chronic illness. Data derived from respondents were analysed statistically. Focus‐group interviews were conducted to assess the semantic and technical equivalence as well as opinions of people about the applicability and relevance of the translated instruments. Results  From 37 instruments identified, the Patients’ Assessment of Care for chronIc Conditions (PACIC) and the short form of the Patient Satisfaction Questionnaire III (PSQ‐18) were selected as most promising instruments. Both instruments produced similar median scores across people with different chronic conditions. The overall PACIC and its subscales and the overall PSQ‐18 were highly internally consistent, but not the PSQ‐18 subscales. Overall, the PACIC demonstrated better psychometric characteristics. PACIC and PSQ‐18 scores were found to be moderately correlated. Whereas more respondents preferred the PSQ‐18, focus‐group participants regarded the PACIC to be more applicable and relevant. The technical and semantic equivalence of both instruments were sufficient. Conclusions  Because of its psychometric characteristics, perceived applicability and relevance, the PACIC is the most appropriate instrument to

  4. Increased Science Instrumentation Funding Strengthens Mars Program

    NASA Technical Reports Server (NTRS)

    Graham, Lee D.; Graff, T. G.

    2012-01-01

    As the strategic knowledge gaps mature for the exploration of Mars, Mars sample return (MSR), and Phobos/Deimos missions, one approach that becomes more probable involves smaller science instrumentation and integrated science suites. Recent technological advances provide the foundation for a significant evolution of instrumentation; however, the funding support is currently too small to fully utilize these advances. We propose that an increase in funding for instrumentation development occur in the near-term so that these foundational technologies can be applied. These instruments would directly address the significant knowledge gaps for humans to Mars orbit, humans to the Martian surface, and humans to Phobos/ Deimos. They would also address the topics covered by the Decadal Survey and the Mars scientific goals, objectives, investigations and priorities as stated by the MEPAG. We argue that an increase of science instrumentation funding would be of great benefit to the Mars program as well as the potential for human exploration of the Mars system. If the total non-Earth-related planetary science instrumentation budget were increased 100% it would not add an appreciable amount to the overall NASA budget and would provide the real potential for future breakthroughs. If such an approach were implemented in the near-term, NASA would benefit greatly in terms of science knowledge of the Mars, Phobos/Deimos system, exploration risk mitigation, technology development, and public interest.

  5. Quantitative evaluation of apical extrusion of debris and irrigants using four rotary instrumentation systems: an in vitro study.

    PubMed

    Nagaveni, S Aspalli; Balakoti, K Reddy; Smita, Karan; Ratnakar, P; Satish, S V; Aravind, T

    2013-11-01

    The apical extrusion of infected debris may have the potential to disrupt the balance between microbial aggression and host defense, resulting in incidents of acute inflammation. During preparation, irrigants and debris, such as bacteria, dentin filings and necrotic tissue may be extruded into the periradicular region leading to periapical inflammation and postoperative flare ups. Using an instrumentation technique that minimizes apical extrusion would be beneficial to both the practitioner and patient. The purpose of the study was to evaluate the weight of debris and volume of irrigant extruded apically from extracted teeth in vitro after endodontic instrumentation using four different rotary root canal instrumentation systems. Four groups of each 20 extracted mandibular premolars were instrumented using one of the four systems: ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland)), Hero-shaper (MicroMega, Besancon, France), RaCe (FKG Dentaire, La-Chaux-de-Fonds, Switzerland) and K3 (SybronEndo, West Collins, CA). Debris and irrigant extruded from the apical foramen during instrumentation were collected in preweighed test tubes. Volume of irrigant extruded was noted. The containers were stored in incubator at 70° for two days to evaporate the moisture. Weight of dry debris was noted. Data was analyzed using Kruskall-Wallis and Mann-Whitney U test at a significance of 0.001. The results indicated that all of the instrumentation systems tested caused measurable apical extrusion of debris and irrigants. Higher extrusion was observed with Protaper system which was statistically significant with Hero-Shaper, RaCe and K3 systems. There were no statistical differences between Hero-shaper, K3 and RaCe systems (p < 0.05). All instrumentation techniques apically extruded debris and irrigant. However, Hero-shaper, K3 and RaCe systems produced less extruded debris and irrigant than the Protaper system.

  6. Age Weights for Health Services Derived from the Relative Social Willingness-to-Pay Instrument.

    PubMed

    Richardson, Jeff; McKie, John; Iezzi, Angelo; Maxwell, Aimee

    2017-04-01

    The effect of a patient's age on the social valuation of health services remains controversial, with empirical results varying in magnitude and implying a different age-value profile. This article employs a new methodology to re-examine these questions. Data were obtained from 2 independent Web-based surveys that administered the Relative Social Willingness to Pay instrument. In the first survey, the age of the patient receiving a life-saving service was varied. Patients were left with either poor mental or physical health. In the second survey, patient age was varied for a service that fully cured the patient's poor mental or physical health. In total, therefore, 4 sets of age weights were obtained: weights for life-extending services with poor physical or mental health outcomes and weights for quality-of-life improvement for patients in poor mental or physical health. Results were consistent. Increasing age was associated in each case with a monotonic decrease in the social valuation of the services. The decrease in value was quantitatively small until age 60 years. By age 80 years, the social value of services had declined by about 50%. The decline commenced at an earlier age in the context of physical health, although the magnitude of the decrement by age 80 years was unrelated to the type of service. With 1 exception, there was little difference in the valuation of services by the age of the survey respondent. Respondents aged >60 years placed a lower, not higher, value on quality-of-life improvement for elderly individuals than other respondents. There was no difference in the valuation of life-extending services.

  7. An Examination of Secondary Wind Instrument Methods Courses

    ERIC Educational Resources Information Center

    Wagoner, Cynthia L.; Juchniewicz, Jay

    2017-01-01

    The purpose of this study was to investigate current secondary woodwind, brass, and combined wind instrument methods courses for preservice music teachers across the United States. Two-hundred eleven (N = 211) wind methods course instructors from National Association of Schools of Music-accredited institutions completed an online survey that…

  8. Ninth Triennial Toxicology Salary Survey.

    PubMed

    Gad, Shayne Cox; Sullivan, Dexter Wayne

    2016-01-01

    This survey serves as the ninth in a series of toxicology salary surveys conducted at 3-year intervals and beginning in 1988. An electronic survey instrument was distributed to 5919 individuals including members of the Society of Toxicology, American College of Toxicology, and 23 additional professional organizations. Question items inquired about gender, age, degree, years of experience, certifications held, areas of specialization, society membership, employment and income. Overall, 1293 responses were received (response rate 21.8%). The results of the 2014 survey provide insight into the job market and career path for current and future toxicologists. © The Author(s) 2016.

  9. Eighth triennial toxicology salary survey.

    PubMed

    Gad, Shayne Cox; Sullivan, Dexter Wayne

    2013-01-01

    This survey serves as the eighth in a series of toxicology salary surveys conducted at 3-year intervals and beginning in 1988. An electronic survey instrument was distributed to 5800 individuals including members of the Society of Toxicology, American College of Toxicology, and 23 additional professional organizations. Question items inquired about gender, age, degree, years of experience, certifications held, areas of specialization, society membership, employment and income. Overall, 2057 responses were received (response rate 35.5%). The results of the 2012 survey provide insight into the job market and career path for current and future toxicologists.

  10. A global quantitative survey of hemostatic assessment in postpartum hemorrhage and experience with associated bleeding disorders.

    PubMed

    James, Andra H; Cooper, David L; Paidas, Michael J

    2017-01-01

    Coagulopathy may be a serious complicating or contributing factor to postpartum hemorrhage (PPH), and should be promptly recognized to ensure proper bleeding management. This study aims to evaluate the approaches of obstetrician-gynecologists worldwide towards assessing massive PPH caused by underlying bleeding disorders. A quantitative survey was completed by 302 obstetrician-gynecologists from 6 countries (the UK, France, Germany, Italy, Spain, and Japan). The survey included questions on the use of hematologic laboratory studies, interpretation of results, laboratory's role in coagulation assessments, and experience with bleeding disorders. Overall, the most common definitions of "massive" PPH were >2,000 mL (39%) and >1,500 mL (34%) blood loss. The most common criteria for rechecking a "stat" complete blood count and for performing coagulation studies were a drop in blood pressure (73%) and ongoing visible bleeding (78%), respectively. Laboratory coagulation (prothrombin time/activated partial thromboplastin time [PT/aPTT]) and factor VIII/IX assays were performed on-site more often than were mixing studies (laboratory coagulation studies, 93%; factor VIII/IX assays, 63%; mixing studies, 22%). Most commonly consulted sources of additional information were colleagues within one's own specialty (68%) and other specialists (67%). Most respondents had consulted with a hematologist (78%; least, Germany [56%]; greatest, UK [98%]). The most common reason for not consulting was hematologist unavailability (44%). The most commonly reported thresholds for concern with PT and aPTT were 13 to 20 seconds (36%) and 30 to 45 seconds (50%), respectively. Most respondents reported having discovered an underlying bleeding disorder (58%; least, Japan [35%]; greatest, Spain [74%]). Global survey results highlight similarities and differences between countries in how PPH is assessed and varying levels of obstetrician-gynecologist experience with identification of underlying

  11. The Electric Field and Waves Instruments on the Radiation Belt Storm Probes Mission

    NASA Astrophysics Data System (ADS)

    Wygant, J. R.; Bonnell, J. W.; Goetz, K.; Ergun, R. E.; Mozer, F. S.; Bale, S. D.; Ludlam, M.; Turin, P.; Harvey, P. R.; Hochmann, R.; Harps, K.; Dalton, G.; McCauley, J.; Rachelson, W.; Gordon, D.; Donakowski, B.; Shultz, C.; Smith, C.; Diaz-Aguado, M.; Fischer, J.; Heavner, S.; Berg, P.; Malsapina, D. M.; Bolton, M. K.; Hudson, M.; Strangeway, R. J.; Baker, D. N.; Li, X.; Albert, J.; Foster, J. C.; Chaston, C. C.; Mann, I.; Donovan, E.; Cully, C. M.; Cattell, C. A.; Krasnoselskikh, V.; Kersten, K.; Brenneman, A.; Tao, J. B.

    2013-11-01

    The Electric Fields and Waves (EFW) Instruments on the two Radiation Belt Storm Probe (RBSP) spacecraft (recently renamed the Van Allen Probes) are designed to measure three dimensional quasi-static and low frequency electric fields and waves associated with the major mechanisms responsible for the acceleration of energetic charged particles in the inner magnetosphere of the Earth. For this measurement, the instrument uses two pairs of spherical double probe sensors at the ends of orthogonal centripetally deployed booms in the spin plane with tip-to-tip separations of 100 meters. The third component of the electric field is measured by two spherical sensors separated by ˜15 m, deployed at the ends of two stacer booms oppositely directed along the spin axis of the spacecraft. The instrument provides a continuous stream of measurements over the entire orbit of the low frequency electric field vector at 32 samples/s in a survey mode. This survey mode also includes measurements of spacecraft potential to provide information on thermal electron plasma variations and structure. Survey mode spectral information allows the continuous evaluation of the peak value and spectral power in electric, magnetic and density fluctuations from several Hz to 6.5 kHz. On-board cross-spectral data allows the calculation of field-aligned wave Poynting flux along the magnetic field. For higher frequency waveform information, two different programmable burst memories are used with nominal sampling rates of 512 samples/s and 16 k samples/s. The EFW burst modes provide targeted measurements over brief time intervals of 3-d electric fields, 3-d wave magnetic fields (from the EMFISIS magnetic search coil sensors), and spacecraft potential. In the burst modes all six sensor-spacecraft potential measurements are telemetered enabling interferometric timing of small-scale plasma structures. In the first burst mode, the instrument stores all or a substantial fraction of the high frequency

  12. Review of Measurement Instruments and Procedures for Assessing Mobility Behaviors: Implications for Quantitative Measurement.

    ERIC Educational Resources Information Center

    Lehr, Donna H.

    The literature review identifies information regarding the emergence of mobility skills in infants and young handicapped children, including rolling, crawling, creeping, and walking. Sections discuss the following topics: assessment instruments relevant to mobility, the identification of developmental milestones in mobility, and a hierarchy of the…

  13. Correlative Instrumental Neutron Activation Analysis, Light Microscopy, Transmission Electron Microscopy, and X-ray Microanalysis for Qualitative and Quantitative Detection of Colloidal Gold Spheres in Biological Specimens

    NASA Astrophysics Data System (ADS)

    Hillyer, Julián F.; Albrecht, Ralph M.

    1998-10-01

    : Colloidal gold, conjugated to ligands or antibodies, is routinely used as a label for the detection of cell structures by light (LM) and electron microscopy (EM). To date, several methods to count the number of colloidal gold labels have been employed with limited success. Instrumental neutron activation analysis (INAA), a physical method for the analysis of the elemental composition of materials, can be used to provide a quantitative index of gold accumulation in bulk specimens. Given that gold is not naturally found in biological specimens in any substantial amount and that colloidal gold and ligand conjugates can be prepared to yield uniform bead sizes, the amount of label can be calculated in bulk biological samples by INAA. Here we describe the use of INAA, LM, transmission EM, and X-ray microanalysis (EDX) in a model to determine both distribution (localization) and amount of colloidal gold at the organ, tissue, cellular, and ultrastructural levels in whole animal systems following administration. In addition, the sensitivity for gold in biological specimens by INAA is compared with that of inductively coupled plasma mass spectrometry (ICP-MS). The correlative use of INAA, LM, TEM, and EDX can be useful, for example, in the quantitative and qualitative tracking of various labeled molecular species following administration in vivo.

  14. Epidemiological survey of quantitative ultrasound in risk assessment of falls in middle-aged and elderly people.

    PubMed

    Ou, Ling-Chun; Sun, Zih-Jie; Chang, Yin-Fan; Chang, Chin-Sung; Chao, Ting-Hsing; Kuo, Po-Hsiu; Lin, Ruey-Mo; Wu, Chih-Hsing

    2013-01-01

    The risk assessment of falls is important, but still unsatisfactory and time-consuming. Our objective was to assess quantitative ultrasound (QUS) in the risk assessment of falls. Our study was designed as epidemiological cross-sectional study occurring from March 2009 to February 2010 by community survey at a medical center. The participants were collected from systemic sample of 1,200 community-dwelling people (Male/Female = 524/676) 40 years old and over in Yunlin County, Mid-Taiwan. Structural questionnaires including socioeconomic status, living status, smoking and drinking habits, exercise and medical history were completed. Quantitative ultrasound (QUS) at the non-dominant distal radial area (QUS-R) and the left calcaneal area (QUS-C) were measured. The overall prevalence of falls was 19.8%. In men, the independently associated factors for falls were age (OR: 1.04; 95%CI: 1.01~1.06), fracture history (OR: 1.89; 95%CI: 1.12~3.19), osteoarthritis history (OR: 3.66; 95%CI: 1.15~11.64) and speed of sound (OR: 0.99; 95%CI: 0.99~1.00; p<0.05) by QUS-R. In women, the independently associated factors for falls were current drinking (OR: 3.54; 95%CI: 1.35∼9.31) and broadband ultrasound attenuation (OR: 0.98; 95%CI: 0.97~0.99; p<0.01) by QUS-C. The cutoffs at -2.5< T-score<-1 derived using QUS-R (OR: 2.85; 95%CI: 1.64~4.96; p<0.01) in men or T-score ≦-2.5 derived using QUS-C (OR: 2.72; 95%CI: 1.42~5.21; p<0.01) in women showed an independent association with falls. The lowest T-score derived using either QUS-R or QUS-C was also revealed as an independent factor for falls in both men (OR: 2.13; 95%CI: 1.03~4.43; p<0.05) and women (OR: 2.36; 95%CI: 1.13~4.91; p<0.05). Quantitative ultrasounds, measured either at the radial or calcaneal area, are convenient tools by which to assess the risk of falls in middle-aged and elderly people.

  15. Development and evaluation of the Fe-BARQ: A new survey instrument for measuring behavior in domestic cats (Felis s. catus).

    PubMed

    Duffy, Deborah L; de Moura, Roseana T Diniz; Serpell, James A

    2017-08-01

    A questionnaire instrument for obtaining quantitative behavioral evaluations of pet cats from cat owners was developed and validated. Exploratory Factor Analysis of 2608 questionnaire responses to 149 behavioral questions/items extracted a total of 23 distinct factors that measured most of the more common dimensions of cat behavior. Seventeen of the 23 factors demonstrated adequate-high internal reliability (Cronbach's alpha=0.712-0.923). Questionnaire validation was accomplished by determining: (a) whether owners' subjective ratings of the severity of their cat's behavior problems were associated with cats' actual scores on expected questionnaire factors, (b) whether expected associations between specific demographic and/or lifestyle characteristics and behavior were confirmed by cats' factor or item scores on the questionnaire, and (c) whether breed rankings based on owner-reported factor scores matched those previously derived from the opinions of experts (veterinarians). The results of these various tests confirmed the overall construct validity of the questionnaire. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  16. Moving beyond Traditional Methods of Survey Validation

    ERIC Educational Resources Information Center

    Maul, Andrew

    2017-01-01

    In his focus article, "Rethinking Traditional Methods of Survey Validation," published in this issue of "Measurement: Interdisciplinary Research and Perspectives," Andrew Maul wrote that it is commonly believed that self-report, survey-based instruments can be used to measure a wide range of psychological attributes, such as…

  17. Use of a formal assessment instrument for evaluation of veterinary student surgical skills.

    PubMed

    Schnabel, Lauren V; Maza, Paul S; Williams, Kimberly M; Irby, Nita L; McDaniel, Carolyn M; Collins, Brian G

    2013-05-01

    To (1) evaluate the design and use of a global rating scale assessment instrument in veterinary medical education and; (2) examine the effectiveness of 2 surgical techniques courses for improving the surgical skills of veterinary students. Instrument development; observational; survey-based. Students (n = 16) registered for 2 elective surgical techniques courses were enrolled on a volunteer basis. A 5-point global rating scale instrument was designed for the evaluation of 12 basic surgical skills by faculty evaluators and used to obtain student start and end scores during the courses. Upon conclusion of the courses, students completed a survey from which their opinions on their improvement as well as their desire for feedback were obtained. All authors agreed the instrument was easy to use. As groups, 3rd year students, 4th year students, and all students combined had significantly higher total skill scores at the end of the courses compared to the start of the courses. Individually, 10 students (63%) had significant improvement in surgical skills as a result of their participation in the courses: 4 (100%) 3rd year and 6 (50%) 4th year students. Student survey responses revealed a strong desire for feedback as well as support of formal assessment methods. Only weak agreement was found between student opinions on their improvement and the authors' assessment scores. Assessment instruments are useful for (1) student evaluation and (2) for providing students with feedback on their surgical skills. © Copyright 2013 by The American College of Veterinary Surgeons.

  18. Results from a U.S. absolute gravity survey

    NASA Astrophysics Data System (ADS)

    Zumberge, M. A.; Faller, J. E.; Gschwind, J.

    Using the recently completed JILA absolute gravity meter, we made a survey of twelve sites in the United States. Over a period of eight weeks, the instrument was driven a total distance of nearly 20,000 km to sites in California, New Mexico, Colorado, Wyoming, Maryland and Massachusetts. The time spent in carrying out a measurement at a single location was typically one day. We report the results of the measurements in this survey along with earlier measurements made with the instrument, discuss the measurement accuracy and compare our results with other measurements.

  19. The UV Survey Mission Concept, CETUS

    NASA Astrophysics Data System (ADS)

    Heap, Sara; and the CETUS Team

    2018-01-01

    In March 2017, NASA selected CETUS for study of a Probe-class mission concept. W. Danchi is the CETUS PI, and S. Heap is the Science PI. CETUS is primarily a UV survey telescope to complement survey telescopes of the 2020’s including E-ROSITA, Subaru Hyper Suprime Cam and Prime-Focus Spectrograph, WFIRST, and the Square Kilometer Array. CETUS comprises a 1.5-m wide-field telescope and three science instruments: a wide-field (1045” on a side) far-UV and near-UV camera; a similarly wide-field near-UV multi-object spectrograph utilizing a next-generation micro-shutter array; and a single-object spectrograph with options of spectral region (far-UV or near-UV) and spectral resolving power (2,000 or 40,000). The survey instruments will operate simultaneously thereby producing wide-field images in the near-UV and far-UV and a spectrogram containing near-UV spectra of up to 100 sources free of spectral overlap and astronomical background. ln concert with other survey telescopes, CETUS will focus on understanding galaxy evolution at cosmic noon (z~1-2).

  20. Quality of data in multiethnic health surveys.

    PubMed Central

    Pasick, R. J.; Stewart, S. L.; Bird, J. A.; D'Onofrio, C. N.

    2001-01-01

    OBJECTIVE: There has been insufficient research on the influence of ethno-cultural and language differences in public health surveys. Using data from three independent studies, the authors examine methods to assess data quality and to identify causes of problematic survey questions. METHODS: Qualitative and quantitative methods were used in this exploratory study, including secondary analyses of data from three baseline surveys (conducted in English, Spanish, Cantonese, Mandarin, and Vietnamese). Collection of additional data included interviews with investigators and interviewers; observations of item development; focus groups; think-aloud interviews; a test-retest assessment survey; and a pilot test of alternatively worded questions. RESULTS: The authors identify underlying causes for the 12 most problematic variables in three multiethnic surveys and describe them in terms of ethnic differences in reliability, validity, and cognitive processes (interpretation, memory retrieval, judgment formation, and response editing), and differences with regard to cultural appropriateness and translation problems. CONCLUSIONS: Multiple complex elements affect measurement in a multiethnic survey, many of which are neither readily observed nor understood through standard tests of data quality. Multiethnic survey questions are best evaluated using a variety of quantitative and qualitative methods that reveal different types and causes of problems. PMID:11889288

  1. Institutional Conservation Program evaluation project: Results of elementary and secondary education survey pretest

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Collins, N.E.; Carroll, W.L.; Gaines, L.L.

    As part of a study of energy conservation efforts in schools and hospitals and an evaluation of the Institutional Conservation Program sponsored by the US Department of Energy, survey instruments that will be sent to large numbers of elementary and secondary schools and school districts were pretested. The survey instruments solicit information on energy conservation activities, decision-making processes, and energy use. The pretest had several purposes, including identification of problems in the survey instruments' formats and in the wording of instructions and questions; it also helped in establishing the sampling strategy for the survey itself. Both site visits and mailingsmore » were used in the pretest. This report covers all aspects of the pretest. Characteristics of the pretest schools, districts, and interviewees are discussed in narrative summaries. Pretest procedures are described and responses to some of the survey questions are provided.« less

  2. Fluorescence calibration method for single-particle aerosol fluorescence instruments

    NASA Astrophysics Data System (ADS)

    Shipley Robinson, Ellis; Gao, Ru-Shan; Schwarz, Joshua P.; Fahey, David W.; Perring, Anne E.

    2017-05-01

    Real-time, single-particle fluorescence instruments used to detect atmospheric bioaerosol particles are increasingly common, yet no standard fluorescence calibration method exists for this technique. This gap limits the utility of these instruments as quantitative tools and complicates comparisons between different measurement campaigns. To address this need, we have developed a method to produce size-selected particles with a known mass of fluorophore, which we use to calibrate the fluorescence detection of a Wideband Integrated Bioaerosol Sensor (WIBS-4A). We use mixed tryptophan-ammonium sulfate particles to calibrate one detector (FL1; excitation = 280 nm, emission = 310-400 nm) and pure quinine particles to calibrate the other (FL2; excitation = 280 nm, emission = 420-650 nm). The relationship between fluorescence and mass for the mixed tryptophan-ammonium sulfate particles is linear, while that for the pure quinine particles is nonlinear, likely indicating that not all of the quinine mass contributes to the observed fluorescence. Nonetheless, both materials produce a repeatable response between observed fluorescence and particle mass. This procedure allows users to set the detector gains to achieve a known absolute response, calculate the limits of detection for a given instrument, improve the repeatability of the instrumental setup, and facilitate intercomparisons between different instruments. We recommend calibration of single-particle fluorescence instruments using these methods.

  3. Measuring decision quality: psychometric evaluation of a new instrument for breast cancer surgery

    PubMed Central

    2012-01-01

    Background The purpose of this paper is to examine the acceptability, feasibility, reliability and validity of a new decision quality instrument that assesses the extent to which patients are informed and receive treatments that match their goals. Methods Cross-sectional mail survey of recent breast cancer survivors, providers and healthy controls and a retest survey of survivors. The decision quality instrument includes knowledge questions and a set of goals, and results in two scores: a breast cancer surgery knowledge score and a concordance score, which reflects the percentage of patients who received treatments that match their goals. Hypotheses related to acceptability, feasibility, discriminant validity, content validity, predictive validity and retest reliability of the survey instrument were examined. Results We had responses from 440 eligible patients, 88 providers and 35 healthy controls. The decision quality instrument was feasible to implement in this study, with low missing data. The knowledge score had good retest reliability (intraclass correlation coefficient = 0.70) and discriminated between providers and patients (mean difference 35%, p < 0.001). The majority of providers felt that the knowledge items covered content that was essential for the decision. Five of the 6 treatment goals met targets for content validity. The five goals had moderate to strong retest reliability (0.64 to 0.87). The concordance score was 89%, indicating that a majority had treatments concordant with that predicted by their goals. Patients who had concordant treatment had similar levels of confidence and regret as those who did not. Conclusions The decision quality instrument met the criteria of feasibility, reliability, discriminant and content validity in this sample. Additional research to examine performance of the instrument in prospective studies and more diverse populations is needed. PMID:22681763

  4. The Community of Inquiry Instrument: Validation and Results in Online Health Care Disciplines

    ERIC Educational Resources Information Center

    Carlon, S.; Bennett-Woods, D.; Berg, B.; Claywell, L.; LeDuc, K.; Marcisz, N.; Mulhall, M.; Noteboom, T.; Snedden, T.; Whalen, K.; Zenoni, L.

    2012-01-01

    This descriptive study using survey design sought to establish the efficacy of the Community of Inquiry instrument utilized in a study published by Shea and Bidjerano in 2009 exploring an online community of business students in a multi-institutional study. The current study sought to validate the instrument with a population of students in three…

  5. Results of the 2013 CASE Europe Salary Survey

    ERIC Educational Resources Information Center

    Paradise, Andrew

    2013-01-01

    CASE has conducted salary surveys to track trends in the profession and to help members benchmark salaries since 1982. Following CASE's major overhaul of the survey instrument and data collection system, CASE Europe fielded a European version of the salary survey for the second time in October 2012. All individual CASE Europe members at colleges,…

  6. Field evaluation of boat-mounted acoustic Doppler instruments used to measure streamflow

    USGS Publications Warehouse

    Mueller, D.S.; ,

    2003-01-01

    The use of instruments based on the Doppler principle for measuring water velocity and computing discharge is common within the U.S. Geological Survey (USGS). The instruments and software have changed appreciably during the last 5 years; therefore, the USGS has begun field validation of the instruments used to make discharge measurements from a moving boat. Instruments manufactured by SonTek/YSI and RD Instruments, Inc. were used to collect discharge data at five different sites. One or more traditional discharge measurements were made using a Price AA current meter and standard USGS procedures concurrent with the acoustic instruments at each site. Discharges measured with the acoustic instruments were compared with discharges measured with Price AA current meters and the USGS stage-discharge rating for each site. The mean discharges measured by each acoustic instrument were within 5 percent of the Price AA-based measurement and (or) discharge from the stage-discharge rating.

  7. MIKiS: The Multi-instrument Kinematic Survey of Galactic Globular Clusters. I. Velocity Dispersion Profiles and Rotation Signals of 11 Globular Clusters

    NASA Astrophysics Data System (ADS)

    Ferraro, F. R.; Mucciarelli, A.; Lanzoni, B.; Pallanca, C.; Lapenna, E.; Origlia, L.; Dalessandro, E.; Valenti, E.; Beccari, G.; Bellazzini, M.; Vesperini, E.; Varri, A.; Sollima, A.

    2018-06-01

    We present the first results of the Multi-Instrument Kinematic Survey of Galactic Globular Clusters (GGCs), a project aimed at exploring the internal kinematics of a representative sample of GGCs from the radial velocity of individual stars, covering the entire radial extension of each system. This is achieved by exploiting the formidable combination of multi-object and integral field unit spectroscopic facilities of the ESO Very Large Telescope. As a first step, here we discuss the results obtained for 11 clusters from high and medium resolution spectra acquired through a combination of FLAMES and KMOS observations. We provide the first kinematical characterization of NGC 1261 and NGC 6496. In all the surveyed systems, the velocity dispersion profile declines at increasing radii, in agreement with the expectation from the King model that best fits the density/luminosity profile. In the majority of the surveyed systems, we find evidence of rotation within a few half-mass radii from the center. These results are in general overall agreement with the predictions of recent theoretical studies, suggesting that the detected signals could be the relic of significant internal rotation set at the epoch of the cluster’s formation. Based on FLAMES and KMOS observations performed at the European Southern Observatory as part of the Large Programme 193.D-0232 (PI: Ferraro).

  8. QUANTITATIVE DECISION TOOLS AND MANAGEMENT DEVELOPMENT PROGRAMS.

    ERIC Educational Resources Information Center

    BYARS, LLOYD L.; NUNN, GEOFFREY E.

    THIS ARTICLE OUTLINED THE CURRENT STATUS OF QUANTITATIVE METHODS AND OPERATIONS RESEARCH (OR), SKETCHED THE STRENGTHS OF TRAINING EFFORTS AND ISOLATED WEAKNESSES, AND FORMULATED WORKABLE CRITERIA FOR EVALUATING SUCCESS OF OPERATIONS RESEARCH TRAINING PROGRAMS. A SURVEY OF 105 COMPANIES REVEALED THAT PERT, INVENTORY CONTROL THEORY AND LINEAR…

  9. Cost-effective instrumentation for quantitative depth measurement of optic nerve head using stereo fundus image pair and image cross correlation techniques

    NASA Astrophysics Data System (ADS)

    de Carvalho, Luis Alberto V.; Carvalho, Valeria

    2014-02-01

    One of the main problems with glaucoma throughout the world is that there are typically no symptoms in the early stages. Many people who have the disease do not know they have it and by the time one finds out, the disease is usually in an advanced stage. Most retinal cameras available in the market today use sophisticated optics and have several other features/capabilities (wide-angle optics, red-free and angiography filters, etc) that make them expensive for the general practice or for screening purposes. Therefore, it is important to develop instrumentation that is fast, effective and economic, in order to reach the mass public in the general eye-care centers. In this work, we have constructed the hardware and software of a cost-effective and non-mydriatic prototype device that allows fast capturing and plotting of high-resolution quantitative 3D images and videos of the optical disc head and neighboring region (30° of field of view). The main application of this device is for glaucoma screening, although it may also be useful for the diagnosis of other pathologies related to the optic nerve.

  10. [Access to health care for an induced abortion: qualitative and quantitative approaches].

    PubMed

    Bajos, N; Moreau, C; Ferrand, M; Bouyer, J

    2003-12-01

    Despite recent studies showing evidence that the organisation of the French health care system raises some problems concerning access to abortion, far little is known on the reality of access conditions and the views of women on the difficulties they experience when they attend an abortion clinic. In this article, we discuss the complementarity of materials from two surveys one qualitative, the other quantitative in the study of patterns of care for an abortion. The qualitative survey included 51 women who reported a history of induced abortion, selected from a qualitative study on unintended pregnancy in France. The quantitative survey included 480 women, who had an abortion in the past 10 years. These women were selected from a representative sample of 2863 women aged 18 to 44, who participated in a study on contraception and abortion. The variety of patterns of care for an abortion, the rareness of dysfunctions in the health care system and the importance of the first professional women contacted, demonstrated in the qualitative survey, were confirmed in the quantitative survey. The quantitative survey enabled quantifying the distribution of the different patterns of care. It also permitted to identify factors associated with the choice of first professional contacted and with the type of subsequent patterns of care. The qualitative survey permitted to explore these patterns of care and to highlight the interaction between the women's request and the representation of the legitimacy of their request. Difficulties of access seemed to be linked to the lack of support women experienced in the process of finding an abortion clinic. Results suggest that general practitioners are less well informed of the procedures required for an abortion than other professionals. However, the qualitative survey also shows that problems of access cannot be reduced to the lack of information of professionals, as their practice was also linked to their own representation of abortion

  11. Summary of Quantitative Interpretation of Image Far Ultraviolet Auroral Data

    NASA Technical Reports Server (NTRS)

    Frey, H. U.; Immel, T. J.; Mende, S. B.; Gerard, J.-C.; Hubert, B.; Habraken, S.; Span, J.; Gladstone, G. R.; Bisikalo, D. V.; Shematovich, V. I.; hide

    2002-01-01

    Direct imaging of the magnetosphere by instruments on the IMAGE spacecraft is supplemented by simultaneous observations of the global aurora in three far ultraviolet (FUV) wavelength bands. The purpose of the multi-wavelength imaging is to study the global auroral particle and energy input from thc magnetosphere into the atmosphere. This paper describes provides the method for quantitative interpretation of FUV measurements. The Wide-Band Imaging Camera (WIC) provides broad band ultraviolet images of the aurora with maximum spatial and temporal resolution by imaging the nitrogen lines and bands between 140 and 180 nm wavelength. The Spectrographic Imager (SI), a dual wavelength monochromatic instrument, images both Doppler-shifted Lyman alpha emissions produced by precipitating protons, in the SI-12 channel and OI 135.6 nm emissions in the SI-13 channel. From the SI-12 Doppler shifted Lyman alpha images it is possible to obtain the precipitating proton flux provided assumptions are made regarding the mean energy of the protons. Knowledge of the proton (flux and energy) component allows the calculation of the contribution produced by protons in the WIC and SI-13 instruments. Comparison of the corrected WIC and SI-13 signals provides a measure of the electron mean energy, which can then be used to determine the electron energy fluxun-. To accomplish this reliable modeling emission modeling and instrument calibrations are required. In-flight calibration using early-type stars was used to validate the pre-flight laboratory calibrations and determine long-term trends in sensitivity. In general, very reasonable agreement is found between in-situ measurements and remote quantitative determinations.

  12. Survey Research: Methods, Issues and the Future

    ERIC Educational Resources Information Center

    Brewer, Ernest W.; Torrisi-Steele, Geraldine; Wang, Victor C. X.

    2015-01-01

    Survey research is prevalent among many professional fields. Both cost effective and time efficient, this method of research is commonly used for the purposes of gaining insight into the attitudes, thoughts, and opinions of populations. Additionally, because there are several types of survey research designs and data collection instruments, the…

  13. Community Needs Assessment Survey Report, Fall 1990.

    ERIC Educational Resources Information Center

    Gainesville Coll., GA. Office of Planning and Institutional Research.

    As part of the Southern Association of Colleges and Schools self-study process for reaffirmation of accreditation, Gainesville College (GC) conducted its second decennial needs assessment survey in fall 1990 to obtain data to assist in college planning and program improvement. Separate survey instruments were developed to gather data from…

  14. Validation of a Spectral Method for Quantitative Measurement of Color in Protein Drug Solutions.

    PubMed

    Yin, Jian; Swartz, Trevor E; Zhang, Jian; Patapoff, Thomas W; Chen, Bartolo; Marhoul, Joseph; Shih, Norman; Kabakoff, Bruce; Rahimi, Kimia

    2016-01-01

    A quantitative spectral method has been developed to precisely measure the color of protein solutions. In this method, a spectrophotometer is utilized for capturing the visible absorption spectrum of a protein solution, which can then be converted to color values (L*a*b*) that represent human perception of color in a quantitative three-dimensional space. These quantitative values (L*a*b*) allow for calculating the best match of a sample's color to a European Pharmacopoeia reference color solution. In order to qualify this instrument and assay for use in clinical quality control, a technical assessment was conducted to evaluate the assay suitability and precision. Setting acceptance criteria for this study required development and implementation of a unique statistical method for assessing precision in 3-dimensional space. Different instruments, cuvettes, protein solutions, and analysts were compared in this study. The instrument accuracy, repeatability, and assay precision were determined. The instrument and assay are found suitable for use in assessing color of drug substances and drug products and is comparable to the current European Pharmacopoeia visual assessment method. In the biotechnology industry, a visual assessment is the most commonly used method for color characterization, batch release, and stability testing of liquid protein drug solutions. Using this method, an analyst visually determines the color of the sample by choosing the closest match to a standard color series. This visual method can be subjective because it requires an analyst to make a judgment of the best match of color of the sample to the standard color series, and it does not capture data on hue and chroma that would allow for improved product characterization and the ability to detect subtle differences between samples. To overcome these challenges, we developed a quantitative spectral method for color determination that greatly reduces the variability in measuring color and allows

  15. The Quantitative Reasoning for College Science (QuaRCS) Assessment: Emerging Themes from 5 Years of Data

    NASA Astrophysics Data System (ADS)

    Follette, Katherine; Dokter, Erin; Buxner, Sanlyn

    2018-01-01

    The Quantitative Reasoning for College Science (QuaRCS) Assessment is a validated assessment instrument that was designed to measure changes in students' quantitative reasoning skills, attitudes toward mathematics, and ability to accurately assess their own quantitative abilities. It has been administered to more than 5,000 students at a variety of institutions at the start and end of a semester of general education college science instruction. I will begin by briefly summarizing our published work surrounding validation of the instrument and identification of underlying attitudinal factors (composite variables identified via factor analysis) that predict 50% of the variation in students' scores on the assessment. I will then discuss more recent unpublished work, including: (1) Development and validation of an abbreviated version of the assessment (The QuaRCS Light), which results in marked improvements in students' ability to maintain a high effort level throughout the assessment and has broad implications for quantitative reasoning assessments in general, and (2) Our efforts to revise the attitudinal portion of the assessment to better assess math anxiety level, another key factor in student performance on numerical assessments.

  16. Patients’ priorities for treatment decision making during periods of incapacity: quantitative survey

    PubMed Central

    RID, ANNETTE; WESLEY, ROBERT; PAVLICK, MARK; MAYNARD, SHARON; ROTH, KATALIN; WENDLER, DAVID

    2017-01-01

    Objective Clinical practice aims to respect patient autonomy by basing treatment decisions for incapacitated patients on their own preferences. Yet many patients do not complete an advance directive, and those who do frequently just designate a family member to make decisions for them. This finding raises the concern that clinical practice may be based on a mistaken understanding of patient priorities. The present study aimed to collect systematic data on how patients prioritize the goals of treatment decision making. Method We employed a self-administered, quantitative survey of patients in a tertiary care center. Results Some 80% or more of the 1169 respondents (response rate = 59.8%) ranked six of eight listed goals for treatment decision making as important. When asked which goal was most important, 38.8% identified obtaining desired or avoiding unwanted treatments, 20.0% identified minimizing stress or financial burden on their family, and 14.6% identified having their family help to make treatment decisions. No single goal was designated as most important by 25.0% of participants. Significance of Results Patients endorsed three primary goals with respect to decision making during periods of incapacity: being treated consistent with their own preferences; minimizing the burden on their family; and involving their family in the decision-making process. However, no single goal was prioritized by a clear majority of patients. These findings suggest that advance care planning should not be limited to documenting patients’ treatment preferences. Clinicians should also discuss and document patients’ priorities for how decisions are to be made. Moreover, future research should evaluate ways to modify current practice to promote all three of patients primary goals for treatment decision making. PMID:25273677

  17. Patients' priorities for treatment decision making during periods of incapacity: quantitative survey.

    PubMed

    Rid, Annette; Wesley, Robert; Pavlick, Mark; Maynard, Sharon; Roth, Katalin; Wendler, David

    2015-10-01

    Clinical practice aims to respect patient autonomy by basing treatment decisions for incapacitated patients on their own preferences. Yet many patients do not complete an advance directive, and those who do frequently just designate a family member to make decisions for them. This finding raises the concern that clinical practice may be based on a mistaken understanding of patient priorities. The present study aimed to collect systematic data on how patients prioritize the goals of treatment decision making. We employed a self-administered, quantitative survey of patients in a tertiary care center. Some 80% or more of the 1169 respondents (response rate = 59.8%) ranked six of eight listed goals for treatment decision making as important. When asked which goal was most important, 38.8% identified obtaining desired or avoiding unwanted treatments, 20.0% identified minimizing stress or financial burden on their family, and 14.6% identified having their family help to make treatment decisions. No single goal was designated as most important by 25.0% of participants. Patients endorsed three primary goals with respect to decision making during periods of incapacity: being treated consistent with their own preferences; minimizing the burden on their family; and involving their family in the decision-making process. However, no single goal was prioritized by a clear majority of patients. These findings suggest that advance care planning should not be limited to documenting patients' treatment preferences. Clinicians should also discuss and document patients' priorities for how decisions are to be made. Moreover, future research should evaluate ways to modify current practice to promote all three of patients primary goals for treatment decision making.

  18. CARMENES instrument control system and operational scheduler

    NASA Astrophysics Data System (ADS)

    Garcia-Piquer, Alvaro; Guàrdia, Josep; Colomé, Josep; Ribas, Ignasi; Gesa, Lluis; Morales, Juan Carlos; Pérez-Calpena, Ana; Seifert, Walter; Quirrenbach, Andreas; Amado, Pedro J.; Caballero, José A.; Reiners, Ansgar

    2014-07-01

    The main goal of the CARMENES instrument is to perform high-accuracy measurements of stellar radial velocities (1m/s) with long-term stability. CARMENES will be installed in 2015 at the 3.5 m telescope in the Calar Alto Observatory (Spain) and it will be equipped with two spectrographs covering from the visible to the near-infrared. It will make use of its near-IR capabilities to observe late-type stars, whose peak of the spectral energy distribution falls in the relevant wavelength interval. The technology needed to develop this instrument represents a challenge at all levels. We present two software packages that play a key role in the control layer for an efficient operation of the instrument: the Instrument Control System (ICS) and the Operational Scheduler. The coordination and management of CARMENES is handled by the ICS, which is responsible for carrying out the operations of the different subsystems providing a tool to operate the instrument in an integrated manner from low to high user interaction level. The ICS interacts with the following subsystems: the near-IR and visible channels, composed by the detectors and exposure meters; the calibration units; the environment sensors; the front-end electronics; the acquisition and guiding module; the interfaces with telescope and dome; and, finally, the software subsystems for operational scheduling of tasks, data processing, and data archiving. We describe the ICS software design, which implements the CARMENES operational design and is planned to be integrated in the instrument by the end of 2014. The CARMENES operational scheduler is the second key element in the control layer described in this contribution. It is the main actor in the translation of the survey strategy into a detailed schedule for the achievement of the optimization goals. The scheduler is based on Artificial Intelligence techniques and computes the survey planning by combining the static constraints that are known a priori (i.e., target

  19. Instrumentation for Non-Invasive Assessment of Cardiovascular Regulation

    NASA Technical Reports Server (NTRS)

    Cohen, Richard J.

    1999-01-01

    It is critically important to be able to assess alterations in cardiovascular regulation during and after space flight. We propose to develop an instrument for the non-invasive assessment of such alterations that can be used on the ground and potentially during space flight. This instrumentation would be used by the Cardiovascular Alterations Team at multiple sites for the study of the effects of space flight on the cardiovascular system and the evaluation of countermeasures. In particular, the Cardiovascular Alterations Team will use this instrumentation in conjunction with ground-based human bed-rest studies and during application of acute stresses e.g., tilt, lower body negative pressure, and exercise. In future studies, the Cardiovascular Alterations Team anticipates using this instrumentation to study astronauts before and after space flight and ultimately, during space flight. The instrumentation may also be used by the Bone Demineralization/Calcium Metabolism Team, the Neurovestibular Team and the Human Performance Factors, Sleep and Chronobiology Team to measure changes in autonomic nervous function. The instrumentation will be based on a powerful new technology - cardiovascular system identification (CSI) - which has been developed in our laboratory. CSI provides a non-invasive approach for the study of alterations in cardiovascular regulation. This approach involves the analysis of second-to-second fluctuations in physiologic signals such as heart rate and non-invasively measured arterial blood pressure in order to characterize quantitatively the physiologic mechanisms responsible for the couplings between these signals. Through the characterization of multiple physiologic mechanisms, CSI provides a closed-loop model of the cardiovascular regulatory state in an individual subject.

  20. The ART-XC Instrument on Board the SRG Mission

    NASA Technical Reports Server (NTRS)

    Pavlinksy, M.; Akimov, V.; Levin, V.; Lapshov, I.; Tkachenko, A.; Semena, N.; Buntov, M.; Glushenko, A.; Arefiev, V.; Yaskovish, A.; hide

    2012-01-01

    Spectrum Roentgen Gamma (SRG) is an X-ray astrophysical observatory, developed by Russia in collaboration with Germany. The mission will be launched in 2014 from Baikonur, by a Zenit rocket with a Fregat booster and placed in a 6-month-period halo orbit around L2. The scientific payload consists of two independent telescopes . a soft-x-ray survey instrument, eROSITA, being provided by Germany and a medium-x-ray-energy survey instrument ART-XC being developed by Russia. ART-XC will consist of seven independent, but co-aligned, telescope modules with seven corresponding cadmium-telluride focal plane detectors. Each will operate over the approximate energy range of 6- 30 keV, with an angular resolution of <1 ', a field of view of 30 ' and an energy resolution about 10% at 14 keV. The NASA Marshall Space Flight Center (MSFC) will fabricate some of the mirror modules, to complement others fabricated by VNIIEF in Russia.

  1. A study into the educational needs of children's hospice doctors: a descriptive quantitative and qualitative survey.

    PubMed

    Amery, Justin; Lapwood, Susie

    2004-12-01

    To identify and explore the educational needs of children's hospice doctors in England. A descriptive quantitative and qualitative survey. Children's hospices in England. All children's hospice doctors (n =55) in England were approached, and 35 (65%) consented. A questionnaire designed to survey doctors' self-assessed educational competencies (confidence and perceived need for training) in subject areas derived from analysis of existing children's palliative care literature. Educational diaries used prospectively in practice to identify areas of unmet educational need. Self-perceived confidence and usefulness scores for each subject area. An analysis of support, education and training needs deriving from educational diaries and one-to-one interviews. Confidence and usefulness scores suggest that respondents would most value support, education and training in the management of emergencies, symptoms and physical disease. Educational diary analysis revealed that respondents would most value support, education and training in communication skills, team-working skills, and personal coping strategies. There is a disparity between educational needs as derived from self-rated competencies and from educational diary keeping; suggesting that children's hospice doctors may not be fully aware of their own educational, support and training needs. Self-rated competencies emphasise the value of education in craft or clinical skills; whereas personal diary keeping emphasises the value of education in intrapersonal and interpersonal skills such as communication, team-working and personal coping skills. The current curricula and educational resources need to acknowledge that interpersonal and intrapersonal competencies are as important as clinical competencies. While the study looks particularly at the educational needs of children's hospice doctors, readers may feel that the findings are of relevance to all specialities and disciplines.

  2. Brazosport Independent School District Community Survey Summary.

    ERIC Educational Resources Information Center

    Brazosport Independent School District, Freeport, TX.

    Results of a 1980-81 survey of the perception of the Brazosport (Freeport, Texas) community regarding the Brazosport Independent School District (BISD) are summarized. The survey instrument consisted of: (1) a cover letter from the superintendent; (2) Part I--a series of multiple-choice questions on various education issues in Brazosport; (3) Part…

  3. Validation of the Care-Related Quality of Life Instrument in different study settings: findings from The Older Persons and Informal Caregivers Survey Minimum DataSet (TOPICS-MDS).

    PubMed

    Lutomski, J E; van Exel, N J A; Kempen, G I J M; Moll van Charante, E P; den Elzen, W P J; Jansen, A P D; Krabbe, P F M; Steunenberg, B; Steyerberg, E W; Olde Rikkert, M G M; Melis, R J F

    2015-05-01

    Validity is a contextual aspect of a scale which may differ across sample populations and study protocols. The objective of our study was to validate the Care-Related Quality of Life Instrument (CarerQol) across two different study design features, sampling framework (general population vs. different care settings) and survey mode (interview vs. written questionnaire). Data were extracted from The Older Persons and Informal Caregivers Minimum DataSet (TOPICS-MDS, www.topics-mds.eu ), a pooled public-access data set with information on >3,000 informal caregivers throughout the Netherlands. Meta-correlations and linear mixed models between the CarerQol's seven dimensions (CarerQol-7D) and caregiver's level of happiness (CarerQol-VAS) and self-rated burden (SRB) were performed. The CarerQol-7D dimensions were correlated to the CarerQol-VAS and SRB in the pooled data set and the subgroups. The strength of correlations between CarerQol-7D dimensions and SRB was weaker among caregivers who were interviewed versus those who completed a written questionnaire. The directionality of associations between the CarerQol-VAS, SRB and the CarerQol-7D dimensions in the multivariate model supported the construct validity of the CarerQol in the pooled population. Significant interaction terms were observed in several dimensions of the CarerQol-7D across sampling frame and survey mode, suggesting meaningful differences in reporting levels. Although good scientific practice emphasises the importance of re-evaluating instrument properties in individual research studies, our findings support the validity and applicability of the CarerQol instrument in a variety of settings. Due to minor differential reporting, pooling CarerQol data collected using mixed administration modes should be interpreted with caution; for TOPICS-MDS, meta-analytic techniques may be warranted.

  4. Characterizing nonconstant instrumental variance in emerging miniaturized analytical techniques.

    PubMed

    Noblitt, Scott D; Berg, Kathleen E; Cate, David M; Henry, Charles S

    2016-04-07

    Measurement variance is a crucial aspect of quantitative chemical analysis. Variance directly affects important analytical figures of merit, including detection limit, quantitation limit, and confidence intervals. Most reported analyses for emerging analytical techniques implicitly assume constant variance (homoskedasticity) by using unweighted regression calibrations. Despite the assumption of constant variance, it is known that most instruments exhibit heteroskedasticity, where variance changes with signal intensity. Ignoring nonconstant variance results in suboptimal calibrations, invalid uncertainty estimates, and incorrect detection limits. Three techniques where homoskedasticity is often assumed were covered in this work to evaluate if heteroskedasticity had a significant quantitative impact-naked-eye, distance-based detection using paper-based analytical devices (PADs), cathodic stripping voltammetry (CSV) with disposable carbon-ink electrode devices, and microchip electrophoresis (MCE) with conductivity detection. Despite these techniques representing a wide range of chemistries and precision, heteroskedastic behavior was confirmed for each. The general variance forms were analyzed, and recommendations for accounting for nonconstant variance discussed. Monte Carlo simulations of instrument responses were performed to quantify the benefits of weighted regression, and the sensitivity to uncertainty in the variance function was tested. Results show that heteroskedasticity should be considered during development of new techniques; even moderate uncertainty (30%) in the variance function still results in weighted regression outperforming unweighted regressions. We recommend utilizing the power model of variance because it is easy to apply, requires little additional experimentation, and produces higher-precision results and more reliable uncertainty estimates than assuming homoskedasticity. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Development and pilot of an international survey: 'Radiation Therapists and Psychosocial Support'.

    PubMed

    Elsner, Kelly L; Naehrig, Diana; Halkett, Georgia K B; Dhillon, Haryana M

    2018-06-07

    Up to one third of radiation therapy patients are reported to have unmet psychosocial needs. Radiation therapists (RTs) have daily contact with patients and can provide daily psychosocial support to reduce patient anxiety, fear and loneliness. However, RTs vary in their values, skills, training, knowledge and involvement in providing psychosocial support. The aims of this study were to: (1) develop an online survey instrument to explore RT values, skills, training and knowledge regarding patient anxiety and psychosocial support, and (2) pilot the instrument with RT professionals to assess content validity, functionality and length. An online cross-sectional survey, titled 'Radiation therapists and psychosocial support' was developed. Items included patient vignettes, embedded items from RT research, and the Professional Quality of Life Scale (ProQOL5). Four radiation oncology departments volunteered to pilot the survey; each nominated four RT staff to participate. Survey data were analysed descriptively and qualitative feedback grouped and coded to determine whether the survey needed to be refined. Thirteen of sixteen RTs completed the pilot survey and feedback form. Median time to completion was 35 mins, with 54% of respondents stating this was too long. Respondents reported content, questions and response options were relevant and appropriate. Feedback was used to: refine the survey instrument, minimise responder burden and drop out and improve functionality and quality of data collection. This pilot of the 'Radiation therapists and psychosocial support' survey instrument demonstrated content validity and usability. The main survey will be circulated to a representative sample of RTs for completion. © 2018 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology.

  6. Career interest, self-efficacy, and perception in undecided and nursing undergraduate students: a quantitative study.

    PubMed

    Fillman, Valentina M

    2015-01-01

    Career choice variables of career interest, self-efficacy, and perception were chosen based upon Social Cognitive Career Theory concepts for study between nursing and undecided undergraduate student groups. Components of the Career Search Questionnaire and Perceptions of Professional Nursing instruments were combined and adapted to form the Career Choice Survey for use in this research. This web-based survey totaling 40 questions was sent to 577 undergraduate students with a 12% response rate (N=68). Due to the need to increase nursing recruitment and retention, hypotheses were developed that distinguish if any relationship existed between groups. Findings of this quantitative study resulted in statistically significant results on two of the three variable hypotheses (p=.006 for career interest, p=.002 for self-efficacy, p=.395 for perception), aligning with previous research and provide insight into the change in nursing perception. Overall, scores for each subscale were encouraging to current nurses and expected from undecided students. Implications for practice include increases in accurate nursing portrayal in the media and early career counseling to younger populations. Nurse educators can further research in career choice with focus on continuing education for current nurses and recruitment of young nursing hopefuls. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Specification for procurement of water-level sensing instrumentation, specification number HIF-I-1

    USGS Publications Warehouse

    Rapp, D.H.

    1982-01-01

    This specification is to communicate to instrument manufacturers the U.S. Geological Survey 's requirements. It covers systems for sensing the elevation of the water surface on open channels, rivers, lakes, reservoirs, storm-sewer pipes, and observation wells at Survey data-collection sites. The signal output (mechanical or electrical) must meet the signal input requirements of analog to digital and digital input recorders in use by the Survey. A classification of stage-sensing systems by common characteristics is used to aid Survey people making system selections. These characteristics are (1) system type (contact or noncontact), (2) sensor type and sensing distance, (3) accuracy, (4) range, (5) power requirements, (6) system size and weight, and (7) data output signal. Acceptable system requirements cover system configurations, signal outputs, materials, operation manuals, detailed environmental conditions, calibration procedures, system accuracy, power requirements, installation limitations, maintainability, safety, and workmanship. An outline of the qualification test procedures and failure criteria are also given. The Hydrologic Instrumentation Facility at NSTL Station, Mississippi will test available systems to determine if they meet the specification in this report for inclusion in the Survey 's 'Qualified Products List'. This list will be used for future procurement of water-level sensing systems by the Survey. (USGS)

  8. Instrument to assess educational programs for parents of children with congenital heart disease undergoing cardiac surgery.

    PubMed

    Pino Armijo, Paola; Ramírez León, Muriel; Clavería Rodríguez, Cristian

    2017-10-01

    To design and validate an instrument to assess the relevance of educational programs for parents of children with congenital heart disease (CHD) undergoing cardiac surgery. In October 2011, an instrument was designed based on Kaufman's model and on the bibliography, and a survey was developed in the form of a checklist with 32 close-ended questions about received education and desired education, categorized into 5 items: educator, time, place, means, and content. The survey was reviewed by 4 academic professionals and 9 experts in the care of children with CHD, and the checklist was extended to include 42 close-ended questions and 5 open questions. The instrument was administered on the day before discharge to the parents of children with CHD undergoing cardiac surgery at the Department of Pediatrics between February and August 2013. The survey was self-administered by the first participants and administered by the investigator among the remaining participants. Fifty-five children met inclusion criteria; a total of 60 parents took part in the study. Agreement was observed between received education and desired education, which was statistically significant only in terms of education provided by a cardiologist (p= 0.000, K= 0.659) and in the hall (p= 0.000, K= 0.655). Statistically significant differences were observed between the 19 self-administered surveys and the 41 surveys administered by the investigator. Among the latter, a greater level of completion was observed for all items. A validated instrument was developed to assess the relevance of educational programs for parents of children with CHD undergoing cardiac surgery. This survey should be administered by a health care provider for a better understanding of information. Sociedad Argentina de Pediatría

  9. Quantitative mass spectrometry methods for pharmaceutical analysis

    PubMed Central

    Loos, Glenn; Van Schepdael, Ann

    2016-01-01

    Quantitative pharmaceutical analysis is nowadays frequently executed using mass spectrometry. Electrospray ionization coupled to a (hybrid) triple quadrupole mass spectrometer is generally used in combination with solid-phase extraction and liquid chromatography. Furthermore, isotopically labelled standards are often used to correct for ion suppression. The challenges in producing sensitive but reliable quantitative data depend on the instrumentation, sample preparation and hyphenated techniques. In this contribution, different approaches to enhance the ionization efficiencies using modified source geometries and improved ion guidance are provided. Furthermore, possibilities to minimize, assess and correct for matrix interferences caused by co-eluting substances are described. With the focus on pharmaceuticals in the environment and bioanalysis, different separation techniques, trends in liquid chromatography and sample preparation methods to minimize matrix effects and increase sensitivity are discussed. Although highly sensitive methods are generally aimed for to provide automated multi-residue analysis, (less sensitive) miniaturized set-ups have a great potential due to their ability for in-field usage. This article is part of the themed issue ‘Quantitative mass spectrometry’. PMID:27644982

  10. Safety Climate Survey: reliability of results from a multicenter ICU survey.

    PubMed

    Kho, M E; Carbone, J M; Lucas, J; Cook, D J

    2005-08-01

    It is important to understand the clinical properties of instruments used to measure patient safety before they are used in the setting of an intensive care unit (ICU). The Safety Climate Survey (SCSu), an instrument endorsed by the Institute for Healthcare Improvement, the Safety Culture Scale (SCSc), and the Safety Climate Mean (SCM), a subset of seven items from the SCSu, were administered in four Canadian university affiliated ICUs. All staff including nurses, allied healthcare professionals, non-clinical staff, intensivists, and managers were invited to participate in the cross sectional survey. The response rate was 74% (313/426). The internal consistency of the SCSu and SCSc was 0.86 and 0.80, respectively, while the SCM performed poorly at 0.51. Because of poor internal consistency, no further analysis of the SCM was therefore performed. Test-retest reliability of the SCSu and SCSc was 0.92. Out of a maximum score of 5, the mean (SD) scores of the SCSu and SCSc were 3.4 (0.6) and 3.4 (0.7), respectively. No differences were noted between the three medical-surgical and one cardiovascular ICU. Managers perceived a significantly more positive safety climate than other staff, as measured by the SCSu and SCSc. These results need to be interpreted cautiously because of the small number of management participants. Of the three instruments, the SCSu and SCSc appear to be measuring one construct and are sufficiently reliable. Future research should examine the properties of patient safety instruments in other ICUs, including responsiveness to change, to ensure that they are valid outcome measures for patient safety initiatives.

  11. Analysis of Six Reviews on the Quality of Instruments for the Evaluation of Interprofessional Education in German-Speaking Countries.

    PubMed

    Ehlers, Jan P; Kaap-Fröhlich, Sylvia; Mahler, Cornelia; Scherer, Theresa; Huber, Marion

    2017-01-01

    Background: More and more institutions worldwide and in German-speaking countries are developing and establishing interprofessional seminars in undergraduate education of health professions. In order to evaluate the different didactic approaches and different outcomes regarding the anticipated interprofessional competencies, it is necessary to apply appropriate instruments. Cross-cultural instruments are particularly helpful for international comparability. The Interprofessional Education working group of the German Medical Association (GMA) aims at identifying existing instruments for the evaluation of interprofessional education in order to make recommendations for German-speaking countries. Methods: Systematic literature research was performed on the websites of international interprofessional organisations (CAIPE, EIPEN, AIPEN), as well as in the PubMed and Cinahl databases. Reviews focusing on quantitative instruments to evaluate competencies according to the modified Kirkpatrick competency levels were searched for. Psychometrics, language/country and setting, in which the instrument was applied, were recorded. Results: Six reviews out of 73 literature research hits were included. A large number of instruments were identified; however, their psychometrics and the applied setting were very heterogeneous. The instruments can mainly be assigned to Kirkpatrick levels 1, 2a & 2b. Most instruments have been developed in English but their psychometrics were not always reported rigorously. Only very few instruments are available in German. Conclusion: It is difficult to find appropriate instruments in German. Internationally, there are different approaches and objectives in the measurement and evaluation of interprofessional competencies. The question arises whether it makes sense to translate existing instruments or to go through the lengthy process of developing new ones. The evaluation of interprofessional seminars with quantitative instruments remains mainly on

  12. Analysis of Six Reviews on the Quality of Instruments for the Evaluation of Interprofessional Education in German-Speaking Countries

    PubMed Central

    Ehlers, Jan P.; Kaap-Fröhlich, Sylvia; Mahler, Cornelia; Scherer, Theresa; Huber, Marion

    2017-01-01

    Background: More and more institutions worldwide and in German-speaking countries are developing and establishing interprofessional seminars in undergraduate education of health professions. In order to evaluate the different didactic approaches and different outcomes regarding the anticipated interprofessional competencies, it is necessary to apply appropriate instruments. Cross-cultural instruments are particularly helpful for international comparability. The Interprofessional Education working group of the German Medical Association (GMA) aims at identifying existing instruments for the evaluation of interprofessional education in order to make recommendations for German-speaking countries. Methods: Systematic literature research was performed on the websites of international interprofessional organisations (CAIPE, EIPEN, AIPEN), as well as in the PubMed and Cinahl databases. Reviews focusing on quantitative instruments to evaluate competencies according to the modified Kirkpatrick competency levels were searched for. Psychometrics, language/country and setting, in which the instrument was applied, were recorded. Results: Six reviews out of 73 literature research hits were included. A large number of instruments were identified; however, their psychometrics and the applied setting were very heterogeneous. The instruments can mainly be assigned to Kirkpatrick levels 1, 2a & 2b. Most instruments have been developed in English but their psychometrics were not always reported rigorously. Only very few instruments are available in German. Conclusion: It is difficult to find appropriate instruments in German. Internationally, there are different approaches and objectives in the measurement and evaluation of interprofessional competencies. The question arises whether it makes sense to translate existing instruments or to go through the lengthy process of developing new ones. The evaluation of interprofessional seminars with quantitative instruments remains mainly on

  13. Feedback to Managers, Volume II: A Review and Comparison of Sixteen Multi-Rater Feedback Instruments.

    ERIC Educational Resources Information Center

    Van Velsor, Ellen; Leslie, Jean Brittain

    "Feedback to Managers" is a two-volume report. Volume 2 compares 16 of the better feedback instruments available. The following are the instruments: (1) ACUMEN Group Feedback; (2) BENCHMARKS; (3) the Campbell Leadership Index; (4) COMPASS: the Managerial Practices Survey; (5) the Executive Success Profile; (6) Leader Behavior Analysis…

  14. A Comparison of Multivariate and Pre-Processing Methods for Quantitative Laser-Induced Breakdown Spectroscopy of Geologic Samples

    NASA Technical Reports Server (NTRS)

    Anderson, R. B.; Morris, R. V.; Clegg, S. M.; Bell, J. F., III; Humphries, S. D.; Wiens, R. C.

    2011-01-01

    The ChemCam instrument selected for the Curiosity rover is capable of remote laser-induced breakdown spectroscopy (LIBS).[1] We used a remote LIBS instrument similar to ChemCam to analyze 197 geologic slab samples and 32 pressed-powder geostandards. The slab samples are well-characterized and have been used to validate the calibration of previous instruments on Mars missions, including CRISM [2], OMEGA [3], the MER Pancam [4], Mini-TES [5], and Moessbauer [6] instruments and the Phoenix SSI [7]. The resulting dataset was used to compare multivariate methods for quantitative LIBS and to determine the effect of grain size on calculations. Three multivariate methods - partial least squares (PLS), multilayer perceptron artificial neural networks (MLP ANNs) and cascade correlation (CC) ANNs - were used to generate models and extract the quantitative composition of unknown samples. PLS can be used to predict one element (PLS1) or multiple elements (PLS2) at a time, as can the neural network methods. Although MLP and CC ANNs were successful in some cases, PLS generally produced the most accurate and precise results.

  15. Instruments, Detectors and the Future of Astronomy with Large Ground Based Telescopes

    NASA Astrophysics Data System (ADS)

    Simons, Douglas A.; Amico, Paola; Baade, Dietrich; Barden, Sam; Campbell, Randall; Finger, Gert; Gilmore, Kirk; Gredel, Roland; Hickson, Paul; Howell, Steve; Hubin, Norbert; Kaufer, Andreas; Kohley, Ralf; MacQueen, Philip; Markelov, Sergej; Merrill, Mike; Miyazaki, Satoshi; Nakaya, Hidehiko; O'Donoghue, Darragh; Oliva, Tino; Richichi, Andrea; Salmon, Derrick; Schmidt, Ricardo; Su, Hongjun; Tulloch, Simon; García Vargas, Maria Luisa; Wagner, R. Mark; Wiecha, Olivier; Ye, Binxun

    2005-01-01

    Results of a survey of instrumentation and detector systems, either currently deployed or planned for use at telescopes larger than 3.5 m, in ground based observatories world-wide, are presented. This survey revealed a number of instrumentation design trends at optical, near, and mid-infrared wavelengths. Some of the most prominent trends include the development of vastly larger optical detector systems (> 109 pixels) than anything built to date, and the frequent use of mosaics of near-infrared detectors - something that was quite rare only a decade ago in astronomy. Some future science applications for detectors are then explored, in an attempt to build a bridge between current detectors and what will be needed to support the research ambitions of astronomers in the future.

  16. The Hyper Suprime-Cam SSP Survey: Overview and survey design

    NASA Astrophysics Data System (ADS)

    Aihara, Hiroaki; Arimoto, Nobuo; Armstrong, Robert; Arnouts, Stéphane; Bahcall, Neta A.; Bickerton, Steven; Bosch, James; Bundy, Kevin; Capak, Peter L.; Chan, James H. H.; Chiba, Masashi; Coupon, Jean; Egami, Eiichi; Enoki, Motohiro; Finet, Francois; Fujimori, Hiroki; Fujimoto, Seiji; Furusawa, Hisanori; Furusawa, Junko; Goto, Tomotsugu; Goulding, Andy; Greco, Johnny P.; Greene, Jenny E.; Gunn, James E.; Hamana, Takashi; Harikane, Yuichi; Hashimoto, Yasuhiro; Hattori, Takashi; Hayashi, Masao; Hayashi, Yusuke; Hełminiak, Krzysztof G.; Higuchi, Ryo; Hikage, Chiaki; Ho, Paul T. P.; Hsieh, Bau-Ching; Huang, Kuiyun; Huang, Song; Ikeda, Hiroyuki; Imanishi, Masatoshi; Inoue, Akio K.; Iwasawa, Kazushi; Iwata, Ikuru; Jaelani, Anton T.; Jian, Hung-Yu; Kamata, Yukiko; Karoji, Hiroshi; Kashikawa, Nobunari; Katayama, Nobuhiko; Kawanomoto, Satoshi; Kayo, Issha; Koda, Jin; Koike, Michitaro; Kojima, Takashi; Komiyama, Yutaka; Konno, Akira; Koshida, Shintaro; Koyama, Yusei; Kusakabe, Haruka; Leauthaud, Alexie; Lee, Chien-Hsiu; Lin, Lihwai; Lin, Yen-Ting; Lupton, Robert H.; Mandelbaum, Rachel; Matsuoka, Yoshiki; Medezinski, Elinor; Mineo, Sogo; Miyama, Shoken; Miyatake, Hironao; Miyazaki, Satoshi; Momose, Rieko; More, Anupreeta; More, Surhud; Moritani, Yuki; Moriya, Takashi J.; Morokuma, Tomoki; Mukae, Shiro; Murata, Ryoma; Murayama, Hitoshi; Nagao, Tohru; Nakata, Fumiaki; Niida, Mana; Niikura, Hiroko; Nishizawa, Atsushi J.; Obuchi, Yoshiyuki; Oguri, Masamune; Oishi, Yukie; Okabe, Nobuhiro; Okamoto, Sakurako; Okura, Yuki; Ono, Yoshiaki; Onodera, Masato; Onoue, Masafusa; Osato, Ken; Ouchi, Masami; Price, Paul A.; Pyo, Tae-Soo; Sako, Masao; Sawicki, Marcin; Shibuya, Takatoshi; Shimasaku, Kazuhiro; Shimono, Atsushi; Shirasaki, Masato; Silverman, John D.; Simet, Melanie; Speagle, Joshua; Spergel, David N.; Strauss, Michael A.; Sugahara, Yuma; Sugiyama, Naoshi; Suto, Yasushi; Suyu, Sherry H.; Suzuki, Nao; Tait, Philip J.; Takada, Masahiro; Takata, Tadafumi; Tamura, Naoyuki; Tanaka, Manobu M.; Tanaka, Masaomi; Tanaka, Masayuki; Tanaka, Yoko; Terai, Tsuyoshi; Terashima, Yuichi; Toba, Yoshiki; Tominaga, Nozomu; Toshikawa, Jun; Turner, Edwin L.; Uchida, Tomohisa; Uchiyama, Hisakazu; Umetsu, Keiichi; Uraguchi, Fumihiro; Urata, Yuji; Usuda, Tomonori; Utsumi, Yousuke; Wang, Shiang-Yu; Wang, Wei-Hao; Wong, Kenneth C.; Yabe, Kiyoto; Yamada, Yoshihiko; Yamanoi, Hitomi; Yasuda, Naoki; Yeh, Sherry; Yonehara, Atsunori; Yuma, Suraphong

    2018-01-01

    Hyper Suprime-Cam (HSC) is a wide-field imaging camera on the prime focus of the 8.2-m Subaru telescope on the summit of Mauna Kea in Hawaii. A team of scientists from Japan, Taiwan, and Princeton University is using HSC to carry out a 300-night multi-band imaging survey of the high-latitude sky. The survey includes three layers: the Wide layer will cover 1400 deg2 in five broad bands (grizy), with a 5 σ point-source depth of r ≈ 26. The Deep layer covers a total of 26 deg2 in four fields, going roughly a magnitude fainter, while the UltraDeep layer goes almost a magnitude fainter still in two pointings of HSC (a total of 3.5 deg2). Here we describe the instrument, the science goals of the survey, and the survey strategy and data processing. This paper serves as an introduction to a special issue of the Publications of the Astronomical Society of Japan, which includes a large number of technical and scientific papers describing results from the early phases of this survey.

  17. A Quantitative Needs Assessment Technique for Cross-Cultural Work Adjustment Training.

    ERIC Educational Resources Information Center

    Selmer, Lyn

    2000-01-01

    A study of 67 Swedish expatriate bosses and 104 local Hong Kong middle managers tested a quantitative needs assessment technique measuring work values. Two-thirds of middle managers' work values were not correctly estimated by their bosses, especially instrumental values (pay, benefits, security, working hours and conditions), indicating a need…

  18. Metrologies for quantitative nanomechanical testing and quality control in semiconductor manufacturing

    NASA Astrophysics Data System (ADS)

    Pratt, Jon R.; Kramar, John A.; Newell, David B.; Smith, Douglas T.

    2005-05-01

    If nanomechanical testing is to evolve into a tool for process and quality control in semiconductor fabrication, great advances in throughput, repeatability, and accuracy of the associated instruments and measurements will be required. A recent grant awarded by the NIST Advanced Technology Program seeks to address the throughput issue by developing a high-speed AFM-based platform for quantitative nanomechanical measurements. The following paper speaks to the issue of quantitative accuracy by presenting an overview of various standards and techniques under development at NIST and other national metrology institutes (NMIs) that can provide a metrological basis for nanomechanical testing. The infrastructure we describe places firm emphasis on traceability to the International System of Units, paving the way for truly quantitative, rather than qualitative, physical property testing.

  19. Full-range public health leadership, part 1: quantitative analysis.

    PubMed

    Carlton, Erik L; Holsinger, James W; Riddell, Martha; Bush, Heather

    2015-01-01

    Workforce and leadership development are central to the future of public health. However, public health has been slow to translate and apply leadership models from other professions and to incorporate local perspectives in understanding public health leadership. This study utilized the full-range leadership model in order to examine public health leadership. Specifically, it sought to measure leadership styles among local health department directors and to understand the context of leadership in local health departments. Leadership styles among local health department directors (n = 13) were examined using survey methodology. Quantitative analysis methods included descriptive statistics, boxplots, and Pearson bivariate correlations using SPSS v18.0. Self-reported leadership styles were highly correlated to leadership outcomes at the organizational level. However, they were not related to county health rankings. Results suggest the preeminence of leader behaviors and providing individual consideration to staff as compared to idealized attributes of leaders, intellectual stimulation, or inspirational motivation. Holistic leadership assessment instruments such as the multifactor leadership questionnaire can be useful in assessing public health leaders' approaches and outcomes. Comprehensive, 360-degree reviews may be especially helpful. Further research is needed to examine the effectiveness of public health leadership development models, as well as the extent that public health leadership impacts public health outcomes.

  20. Cooling the dark energy camera instrument

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmitt, R.L.; Cease, H.; /Fermilab

    2008-06-01

    DECam, camera for the Dark Energy Survey (DES), is undergoing general design and component testing. For an overview see DePoy, et al in these proceedings. For a description of the imager, see Cease, et al in these proceedings. The CCD instrument will be mounted at the prime focus of the CTIO Blanco 4m telescope. The instrument temperature will be 173K with a heat load of 113W. In similar applications, cooling CCD instruments at the prime focus has been accomplished by three general methods. Liquid nitrogen reservoirs have been constructed to operate in any orientation, pulse tube cryocoolers have been usedmore » when tilt angles are limited and Joule-Thompson or Stirling cryocoolers have been used with smaller heat loads. Gifford-MacMahon cooling has been used at the Cassegrain but not at the prime focus. For DES, the combined requirements of high heat load, temperature stability, low vibration, operation in any orientation, liquid nitrogen cost and limited space available led to the design of a pumped, closed loop, circulating nitrogen system. At zenith the instrument will be twelve meters above the pump/cryocooler station. This cooling system expected to have a 10,000 hour maintenance interval. This paper will describe the engineering basis including the thermal model, unbalanced forces, cooldown time, the single and two-phase flow model.« less

  1. Rasch Analysis for Instrument Development: Why, When, and How?

    ERIC Educational Resources Information Center

    Boone, William J.

    2016-01-01

    This essay describes Rasch analysis psychometric techniques and how such techniques can be used by life sciences education researchers to guide the development and use of surveys and tests. Specifically, Rasch techniques can be used to document and evaluate the measurement functioning of such instruments. Rasch techniques also allow researchers to…

  2. Development and validation of an instrument to measure nurse educator perceived confidence in clinical teaching.

    PubMed

    Nguyen, Van N B; Forbes, Helen; Mohebbi, Mohammadreza; Duke, Maxine

    2017-12-01

    Teaching nursing in clinical environments is considered complex and multi-faceted. Little is known about the role of the clinical nurse educator, specifically the challenges related to transition from clinician, or in some cases, from newly-graduated nurse to that of clinical nurse educator, as occurs in developing countries. Confidence in the clinical educator role has been associated with successful transition and the development of role competence. There is currently no valid and reliable instrument to measure clinical nurse educator confidence. This study was conducted to develop and psychometrically test an instrument to measure perceived confidence among clinical nurse educators. A multi-phase, multi-setting survey design was used. A total of 468 surveys were distributed, and 363 were returned. Data were analyzed using exploratory and confirmatory factor analyses. The instrument was successfully tested and modified in phase 1, and factorial validity was subsequently confirmed in phase 2. There was strong evidence of internal consistency, reliability, content, and convergent validity of the Clinical Nurse Educator Skill Acquisition Assessment instrument. The resulting instrument is applicable in similar contexts due to its rigorous development and validation process. © 2017 The Authors. Nursing & Health Sciences published by John Wiley & Sons Australia, Ltd.

  3. 76 FR 12367 - Proposed Information Collection; Visibility Valuation Survey Pilot Study

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-07

    ... Survey Pilot Study AGENCY: National Park Service, U.S. Department of the Interior. ACTION: Notice... Code of Federal Regulations). Updated estimates of visibility benefits are required because the studies... a pilot study to test the survey instrument and implementation procedures prior to the full survey...

  4. Residential Energy Consumption Survey (RECS): Household screener survey, 1979-1980, household characteristics and annualized consumption

    NASA Astrophysics Data System (ADS)

    Windell, P.

    1981-08-01

    This document provides basic information and technical specifications necessary for using the machine-readable magnetic tape containing data from the Household Screener Survey of the Residential Energy Consumption Survey (RECS). Included in this document are an overview of the RECS and a brief description of the Household Screener Survey. The next section contains technical specifications for reading the tape and descriptions of the contents of each of the files contained on the tape. The remaining four sections are devoted to technical topics of special interest to users of the data. Appended to this document are copies of the fieldwork instruments used in the survey and a listing of the contents of a portion of the SPSS labels information.

  5. Development and validation of a quantitative method to assess pedicle screw loosening in posterior spine instrumentation on plain radiographs.

    PubMed

    Aghayev, Emin; Zullig, Nicolas; Diel, Peter; Dietrich, Daniel; Benneker, Lorin M

    2014-03-01

    Currently, the diagnosis of pedicle screw (PS) loosening is based on a subjectively assessed halo sign, that is, a radiolucent line around the implant wider than 1 mm in plain radiographs. We aimed at development and validation of a quantitative method to diagnose PS loosening on radiographs. Between 11/2004 and 1/2010 36 consecutive patients treated with thoraco-lumbar spine fusion with PS instrumentation without PS loosening were compared with 37 other patients who developed a clinically manifesting PS loosening. Three different angles were measured and compared regarding their capability to discriminate the loosened PS over the postoperative course. The inter-observer invariance was tested and a receiver operating characteristics curve analysis was performed. The angle measured between the PS axis and the cranial endplate was significantly different between the early and all later postoperative images. The Spearman correlation coefficient for the measurements of two observers at each postoperative time point ranged between 0.89 at 2 weeks to 0.94 at 2 months and 1 year postoperative. The angle change of 1.9° between immediate postoperative and 6-month postoperative was 75% sensitive and 89% specific for the identification of loosened screws (AUC = 0.82). The angle between the PS axis and the cranial endplate showed good ability to change in PS loosening. A change of this angle of at least 2° had a relatively high sensitivity and specificity to diagnose screw loosening.

  6. Construction of a survey to assess workload and fatigue among AMT operators in Mexico.

    PubMed

    Hernández Arellano, Juan Luis; Ibarra Mejía, Gabriel; Serratos Pérez, J Nieves; García Alcaraz, Jorge Luis; Brunette, María Julia

    2012-01-01

    Operators of machinery classified as Advanced Manufacturing Technology (AMT) are exposed to high levels of workload and fatigue. However, only few studies have been conducted on this topic in Hispanic-American countries workers. Several instruments be used to assess workload and fatigue; however, only few of them have been adapted to Spanish language. This paper reports on the development and validity testing of a survey instrument in Spanish, aiming to subjectively assess workload and fatigue among AMT operators in Mexico. After an exhaustive literature review in search of already available measurement instruments, they were adapted for content and later translated into Spanish; a pilot test was conducted to evaluate validity and reliability; afterwards appropriate modifications were made to the testing instruments. Final version of the instrument was applied to a group of 121 operators of CNC lathes. Reliability was analyzed using KMO and Cronbach alpha indices. For the assessment of workload, both NASA-TLX and ISTAS 21 methods were incorporated to the survey instrument. As for fatigue assessment tools, these were SOFI-S, FAS and OFER questionnaires. RESULTS show KMO value and Cronbach alpha above 0.6.Conclusions. The survey instrument as designed, allows the collection of reliable and valid data regarding workload and fatigue among AMT operators in Mexico.

  7. Shuttle Tethered Aerothermodynamics Research Facility (STARFAC) Instrumentation Requirements

    NASA Technical Reports Server (NTRS)

    Wood, George M.; Siemers, Paul M.; Carlomagno, Giovanni M.; Hoffman, John

    1986-01-01

    The instrumentation requirements for the Shuttle Tethered Aerothermodynamic Research Facility (STARFAC) are presented. The typical physical properties of the terrestrial atmosphere are given along with representative atmospheric daytime ion concentrations and the equilibrium and nonequilibrium gas property comparison from a point away from a wall. STARFAC science and engineering measurements are given as are the TSS free stream gas analysis. The potential nonintrusive measurement techniques for hypersonic boundary layer research are outlined along with the quantitative physical measurement methods for aerothermodynamic studies.

  8. Evaluations of Capacity to Waive Miranda Rights: A Survey of Practitioners' Use of the Grisso Instruments

    ERIC Educational Resources Information Center

    Ryba, Nancy L.; Brodsky, Stanley L.; Shlosberg, Amy

    2007-01-01

    Minimal information is available regarding the frequency with which practitioners conduct evaluations of capacity to waive Miranda rights or what approaches they use in doing so. Grisso's Instruments for Assessing Understanding and Appreciation of Miranda Rights are the only published instruments designed specifically to assist practitioners in…

  9. Neurologic examination and instrument-based measurements in the evaluation of ulnar neuropathy at the elbow.

    PubMed

    Omejec, Gregor; Podnar, Simon

    2018-06-01

    The aim of the study was to compare the utility of instrument-based assessment of peripheral nerve function with the neurologic examination in ulnar neuropathy at the elbow (UNE). We prospectively recruited consecutive patients with suspected UNE, performed a neurologic examination, and performed instrument-based measurements (muscle cross-sectional area by ultrasonography, muscle strength by dynamometry, and sensation using monofilaments). We found good correlations between clinical estimates and corresponding instrument-based measurements, with similar ability to diagnose UNE and predict UNE pathophysiology. Although instrument-based methods provide quantitative evaluation of peripheral nerve function, we did not find them to be more sensitive or specific in the diagnosis of UNE than the standard neurologic examination. Likewise, instrument-based methods were not better able to differentiate between groups of UNE patients with different pathophysiologies. Muscle Nerve 57: 951-957, 2018. © 2017 Wiley Periodicals, Inc.

  10. The Napa Project: 02 Year Annual Drug Survey.

    ERIC Educational Resources Information Center

    Moskowitz, Joel M.; And Others

    The results of a survey administered to junior and senior high students in the Napa Valley (CA) Unified School District in 1980 are summarized. The questionnaire administered was the Drug and Alcohol Survey, a group administered, self-report instrument. The questionnaire assesses: (1) drug knowledge; (2) general drug attitudes; (3) perceived…

  11. Quantitative Evaluation of Ion-implanted Arsenic in Silicon by Instrumental Neutron Activation Analysis

    NASA Astrophysics Data System (ADS)

    Takatsuka, Toshiko; Hirata, Kouichi; Kobayashi, Yoshinori; Kuroiwa, Takayoshi; Miura, Tsutomu; Matsue, Hideaki

    2008-11-01

    Certified reference materials (CRMs) of shallow arsenic implants in silicon are now under development at the National Metrology Institute of Japan (NMIJ). The amount of ion-implanted arsenic atoms is quantified by Instrumental Neutron Activation Analysis (INAA) using research reactor JRR-3 in Japan Atomic Energy Agency (JAEA). It is found that this method can evaluate arsenic amounts of 1015 atoms/cm2 with small uncertainties, and is adaptable to shallower dopants. The estimated uncertainties can satisfy the industrial demands for reference materials to calibrate the implanted dose of arsenic at shallow junctions.

  12. 10 CFR 35.404 - Surveys after source implant and removal.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... patient or a human research subject, the licensee shall make a survey to locate and account for all... from a patient or a human research subject, the licensee shall make a survey of the patient or the human research subject with a radiation detection survey instrument to confirm that all sources have...

  13. 10 CFR 35.404 - Surveys after source implant and removal.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... patient or a human research subject, the licensee shall make a survey to locate and account for all... from a patient or a human research subject, the licensee shall make a survey of the patient or the human research subject with a radiation detection survey instrument to confirm that all sources have...

  14. 10 CFR 35.404 - Surveys after source implant and removal.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... patient or a human research subject, the licensee shall make a survey to locate and account for all... from a patient or a human research subject, the licensee shall make a survey of the patient or the human research subject with a radiation detection survey instrument to confirm that all sources have...

  15. 10 CFR 35.404 - Surveys after source implant and removal.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... patient or a human research subject, the licensee shall make a survey to locate and account for all... from a patient or a human research subject, the licensee shall make a survey of the patient or the human research subject with a radiation detection survey instrument to confirm that all sources have...

  16. 10 CFR 35.404 - Surveys after source implant and removal.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... patient or a human research subject, the licensee shall make a survey to locate and account for all... from a patient or a human research subject, the licensee shall make a survey of the patient or the human research subject with a radiation detection survey instrument to confirm that all sources have...

  17. Hybrid gravity survey to search for submarine ore deposit

    NASA Astrophysics Data System (ADS)

    Araya, A.; Kanazawa, T.; Fujimoto, H.; Shinohara, M.; Yamada, T.; Mochizuki, K.; Iizasa, K.; Ishihara, T.; Omika, S.

    2011-12-01

    Along with seismic surveys, gravity survey is a useful method to profile the underground density structure. We propose a hybrid gravity survey using gravimeters and gravity gradiometers to detect submarine ore deposits as density anomalies by towing the instruments using an AUV (Autonomous Underwater Vehicle) or an ROV (Remotely Operated Vehicle). Gravimeters measure the regional density structure below the seafloor, whereas gravity gradiometers are sensitive to localized mass distribution. A gravity gradiometer comprises two accelerometers arranged with a vertical separation, and a gravity gradient can be obtained from the acceleration difference. Compared to gravimeters, gravity gradiometers are insensitive to common disturbances such as parallel acceleration, thermal drift, and apparent gravity effect (Eötvös effect). We made two accelerometers using astatic pendulums, and obtained common acceleration reduction more than two orders of magnitude. With these pendulums of 500-mm separation, resolution of 7E (=7x10^{-9}(1/s^2)), enough to detect a typical ore deposit buried 50m below the seafloor, was evaluated. During measurements using a submersible mobile object, instrument orientation is required to be controlled to keep verticality and to reduce centrifugal force associated with rotation of the instrument. Using a gyro and a tiltmeter, angular rotation was shown to be controlled within 0.001deg/s which corresponds to 0.3E in effective gravity gradient due to the centrifugal force. In this paper, target of this research, details of the instruments and their performance, and development for the submarine gravity survey using an AUV will be presented.

  18. Future states: the axioms underlying prospective, future-oriented, health planning instruments.

    PubMed

    Koch, T

    2001-02-01

    Proscriptive planning exercises are critical to and generally accepted as integral to health planning at varying scales. These require specific instruments designed to predict future actions on the basis of present knowledge. At the macro-level of health economics, for example, a number of future-oriented Quality of Life Instruments (QL) are commonly employed. At the level of individual decision making, on the other hand, Advance Directives (AD's) are advanced as a means by which healthy individuals can assure their wishes will be carried out if at some future point they are incapacitated. As proscriptive tools, both instrument classes appear to share an axiomatic set whose individual parts have not been rigorously considered. This paper attempts to first identify and then consider a set of five axioms underlying future oriented health planning instruments. These axioms are then critiqued using data from a pre-test survey designed specifically to address their assumptions. Results appear to challenge the validity of the axioms underlying the proscriptive planning instruments.

  19. The Job Training and Job Satisfaction Survey Technical Manual

    ERIC Educational Resources Information Center

    Schmidt, Steven W.

    2004-01-01

    Job training has become an important aspect of an employee's overall job experience. However, it is not often called out specifically on instruments measuring job satisfaction. This technical manual details the processes used in the development and validation of a survey instrument to measure job training satisfaction and overall job…

  20. Novel Developments in Instrumentation for PET Imaging

    NASA Astrophysics Data System (ADS)

    Karp, Joel

    2013-04-01

    Advances in medical imaging, in particular positron emission tomography (PET), have been based on technical developments in physics and instrumentation that have common foundations with detection systems used in other fields of physics. New detector materials are used in PET systems that maximize efficiency, timing characteristics and robustness, and which lead to improved image quality and quantitative accuracy for clinical imaging. Time of flight (TOF) techniques are now routinely used in commercial PET scanners that combine physiological imaging with anatomical imaging provided by x-ray computed tomography. Using new solid-state photo-sensors instead of traditional photo-multiplier tubes makes it possible to combine PET with magnetic resonance imaging which is a significant technical challenge, but one that is creating new opportunities for both research and clinical applications. An overview of recent advances in instrumentation, such as TOF and PET/MR will be presented, along with examples of imaging studies to demonstrate the impact on patient care and basic research of diseases.