Sample records for quantitative test results

  1. A comparison of manual and quantitative elbow strength testing.

    PubMed

    Shahgholi, Leili; Bengtson, Keith A; Bishop, Allen T; Shin, Alexander Y; Spinner, Robert J; Basford, Jeffrey R; Kaufman, Kenton R

    2012-10-01

    The aim of this study was to compare the clinical ratings of elbow strength obtained by skilled clinicians with objective strength measurement obtained through quantitative testing. A retrospective comparison of subject clinical records with quantitative strength testing results in a motion analysis laboratory was conducted. A total of 110 individuals between the ages of 8 and 65 yrs with traumatic brachial plexus injuries were identified. Patients underwent manual muscle strength testing as assessed on the 5-point British Medical Research Council Scale (5/5, normal; 0/5, absent) and quantitative elbow flexion and extension strength measurements. A total of 92 subjects had elbow flexion testing. Half of the subjects clinically assessed as having normal (5/5) elbow flexion strength on manual muscle testing exhibited less than 42% of their age-expected strength on quantitative testing. Eighty-four subjects had elbow extension strength testing. Similarly, half of those displaying normal elbow extension strength on manual muscle testing were found to have less than 62% of their age-expected values on quantitative testing. Significant differences between manual muscle testing and quantitative findings were not detected for the lesser (0-4) strength grades. Manual muscle testing, even when performed by experienced clinicians, may be more misleading than expected for subjects graded as having normal (5/5) strength. Manual muscle testing estimates for the lesser strength grades (1-4/5) seem reasonably accurate.

  2. Comparison of intradermal dilutional testing, skin prick testing, and modified quantitative testing for common allergens.

    PubMed

    Peltier, Jacques; Ryan, Matthew W

    2007-08-01

    To compare and correlate wheal size using the Multi-Test II applicator with the endpoint obtained by intradermal dilutional testing (IDT) for 5 common allergens. To examine the safety of modified quantitative testing (MQT) for determining immunotherapy starting doses. Prospective comparative clinical study. A total of 134 subjects were simultaneously skin tested for immediate hypersensitivity using the Multi-Test II device and IDT. There was a 77% concordance between results from IDT and results from MQT. When there was a difference, MQT predicted a safer endpoint for starting immunotherapy in all but 2 cases. Wheal size by SPT is predictive of endpoint by IDT. MQT is nearly as effective as formal IDT in determining endpoint. Modified quantitative testing appears to be a safe alternative to IDT for determining starting doses for immunotherapy.

  3. Generalized likelihood ratios for quantitative diagnostic test scores.

    PubMed

    Tandberg, D; Deely, J J; O'Malley, A J

    1997-11-01

    The reduction of quantitative diagnostic test scores to the dichotomous case is a wasteful and unnecessary simplification in the era of high-speed computing. Physicians could make better use of the information embedded in quantitative test results if modern generalized curve estimation techniques were applied to the likelihood functions of Bayes' theorem. Hand calculations could be completely avoided and computed graphical summaries provided instead. Graphs showing posttest probability of disease as a function of pretest probability with confidence intervals (POD plots) would enhance acceptance of these techniques if they were immediately available at the computer terminal when test results were retrieved. Such constructs would also provide immediate feedback to physicians when a valueless test had been ordered.

  4. Progress in Quantitative Viral Load Testing: Variability and Impact of the WHO Quantitative International Standards

    PubMed Central

    Sun, Y.; Tang, L.; Procop, G. W.; Hillyard, D. R.; Young, S. A.; Caliendo, A. M.

    2016-01-01

    ABSTRACT It has been hoped that the recent availability of WHO quantitative standards would improve interlaboratory agreement for viral load testing; however, insufficient data are available to evaluate whether this has been the case. Results from 554 laboratories participating in proficiency testing surveys for quantitative PCR assays of cytomegalovirus (CMV), Epstein-Barr virus (EBV), BK virus (BKV), adenovirus (ADV), and human herpesvirus 6 (HHV6) were evaluated to determine overall result variability and then were stratified by assay manufacturer. The impact of calibration to international units/ml (CMV and EBV) on variability was also determined. Viral loads showed a high degree of interlaboratory variability for all tested viruses, with interquartile ranges as high as 1.46 log10 copies/ml and the overall range for a given sample up to 5.66 log10 copies/ml. Some improvement in result variability was seen when international units were adopted. This was particularly the case for EBV viral load results. Variability in viral load results remains a challenge across all viruses tested here; introduction of international quantitative standards may help reduce variability and does so more or less markedly for certain viruses. PMID:27852673

  5. Qualitative and Quantitative Detection of Botulinum Neurotoxins from Complex Matrices: Results of the First International Proficiency Test

    PubMed Central

    Worbs, Sylvia; Fiebig, Uwe; Zeleny, Reinhard; Schimmel, Heinz; Rummel, Andreas; Luginbühl, Werner; Dorner, Brigitte G.

    2015-01-01

    In the framework of the EU project EQuATox, a first international proficiency test (PT) on the detection and quantification of botulinum neurotoxins (BoNT) was conducted. Sample materials included BoNT serotypes A, B and E spiked into buffer, milk, meat extract and serum. Different methods were applied by the participants combining different principles of detection, identification and quantification. Based on qualitative assays, 95% of all results reported were correct. Successful strategies for BoNT detection were based on a combination of complementary immunological, MS-based and functional methods or on suitable functional in vivo/in vitro approaches (mouse bioassay, hemidiaphragm assay and Endopep-MS assay). Quantification of BoNT/A, BoNT/B and BoNT/E was performed by 48% of participating laboratories. It turned out that precise quantification of BoNT was difficult, resulting in a substantial scatter of quantitative data. This was especially true for results obtained by the mouse bioassay which is currently considered as “gold standard” for BoNT detection. The results clearly demonstrate the urgent need for certified BoNT reference materials and the development of methods replacing animal testing. In this context, the BoNT PT provided the valuable information that both the Endopep-MS assay and the hemidiaphragm assay delivered quantitative results superior to the mouse bioassay. PMID:26703724

  6. [THE COMPARATIVE ANALYSIS OF RESULTS OF DETECTION OF CARCINOGENIC TYPES OF HUMAN PAPILLOMA VIRUS BY QUALITATIVE AND QUANTITATIVE TESTS].

    PubMed

    Kuzmenko, E T; Labigina, A V; Leshenko, O Ya; Rusanov, D N; Kuzmenko, V V; Fedko, L P; Pak, I P

    2015-05-01

    The analysis of results of screening (n = 3208; sexually active citizen aged from 18 to 59 years) was carried out to detect oncogene types of human papilloma virus in using qualitative (1150 females and 720 males) and quantitative (polymerase chain reaction in real-time (843 females and 115 males) techniques. The human papilloma virus of high oncogene type was detected in 65% and 68.4% of females and in 48.6% and 53% of males correspondingly. Among 12 types of human papilloma virus the most frequently diagnosed was human papilloma virus 16 independently of gender of examined and technique of analysis. In females, under application of qualitative tests rate of human papilloma virus 16 made up to 18.3% (n = 280) and under application of quantitative tests Rte of human papilloma virus made up to 14.9% (n = 126; p ≤ 0.05). Under examination of males using qualitative tests rate of human papilloma virus 16 made up to 8.3% (n = 60) and under application of qualitative tests made up to 12.2% (n = 14; p ≥ 0.05). Under application of qualitative tests rate of detection on the rest ofoncogene types of human papilloma virus varied in females from 3.4% to 8.4% and in males from 1.8% to 5.9%. Under application of qualitative tests to females rate of human papilloma virus with high viral load made up to 68.4%, with medium viral load - 2.85% (n = 24) and with low viral load -0.24% (n = 2). Under application of quantitative tests in males rate of detection of types of human papilloma virus made up to 53% and at that in all high viral load was established. In females, the most of oncogene types of human papilloma virus (except for 31, 39, 59) are detected significantly more often than in males.

  7. Qualitative versus Quantitative Results: An Experimental Introduction to Data Interpretation.

    ERIC Educational Resources Information Center

    Johnson, Eric R.; Alter, Paula

    1989-01-01

    Described is an experiment in which the student can ascertain the meaning of a negative result from a qualitative test by performing a more sensitive quantitative test on the same sample. Methodology for testing urinary glucose with a spectrophotometer at 630 nm and with commercial assaying glucose strips is presented. (MVL)

  8. Interlaboratory Comparison of Quantitative PCR Test Results for Dehalococcoides

    EPA Science Inventory

    Quantitative PCR (qPCR) techniques have been widely used to measure Dehalococcoides (Dhc) DNA in the groundwater at field sites for several years. Interpretation of these data may be complicated when different laboratories using alternate methods conduct the analysis. An...

  9. Quantitative optical scanning tests of complex microcircuits

    NASA Technical Reports Server (NTRS)

    Erickson, J. J.

    1980-01-01

    An approach for the development of the optical scanner as a screening inspection instrument for microcircuits involves comparing the quantitative differences in photoresponse images and then correlating them with electrical parameter differences in test devices. The existing optical scanner was modified so that the photoresponse data could be recorded and subsequently digitized. A method was devised for applying digital image processing techniques to the digitized photoresponse data in order to quantitatively compare the data. Electrical tests were performed and photoresponse images were recorded before and following life test intervals on two groups of test devices. Correlations were made between differences or changes in the electrical parameters of the test devices.

  10. QTest: Quantitative Testing of Theories of Binary Choice.

    PubMed

    Regenwetter, Michel; Davis-Stober, Clintin P; Lim, Shiau Hong; Guo, Ying; Popova, Anna; Zwilling, Chris; Cha, Yun-Shil; Messner, William

    2014-01-01

    The goal of this paper is to make modeling and quantitative testing accessible to behavioral decision researchers interested in substantive questions. We provide a novel, rigorous, yet very general, quantitative diagnostic framework for testing theories of binary choice. This permits the nontechnical scholar to proceed far beyond traditionally rather superficial methods of analysis, and it permits the quantitatively savvy scholar to triage theoretical proposals before investing effort into complex and specialized quantitative analyses. Our theoretical framework links static algebraic decision theory with observed variability in behavioral binary choice data. The paper is supplemented with a custom-designed public-domain statistical analysis package, the QTest software. We illustrate our approach with a quantitative analysis using published laboratory data, including tests of novel versions of "Random Cumulative Prospect Theory." A major asset of the approach is the potential to distinguish decision makers who have a fixed preference and commit errors in observed choices from decision makers who waver in their preferences.

  11. QTest: Quantitative Testing of Theories of Binary Choice

    PubMed Central

    Regenwetter, Michel; Davis-Stober, Clintin P.; Lim, Shiau Hong; Guo, Ying; Popova, Anna; Zwilling, Chris; Cha, Yun-Shil; Messner, William

    2014-01-01

    The goal of this paper is to make modeling and quantitative testing accessible to behavioral decision researchers interested in substantive questions. We provide a novel, rigorous, yet very general, quantitative diagnostic framework for testing theories of binary choice. This permits the nontechnical scholar to proceed far beyond traditionally rather superficial methods of analysis, and it permits the quantitatively savvy scholar to triage theoretical proposals before investing effort into complex and specialized quantitative analyses. Our theoretical framework links static algebraic decision theory with observed variability in behavioral binary choice data. The paper is supplemented with a custom-designed public-domain statistical analysis package, the QTest software. We illustrate our approach with a quantitative analysis using published laboratory data, including tests of novel versions of “Random Cumulative Prospect Theory.” A major asset of the approach is the potential to distinguish decision makers who have a fixed preference and commit errors in observed choices from decision makers who waver in their preferences. PMID:24999495

  12. Semi-Quantitative Scoring of an Immunochromatographic Test for Circulating Filarial Antigen

    PubMed Central

    Chesnais, Cédric B.; Missamou, François; Pion, Sébastien D. S.; Bopda, Jean; Louya, Frédéric; Majewski, Andrew C.; Weil, Gary J.; Boussinesq, Michel

    2013-01-01

    The value of a semi-quantitative scoring of the filarial antigen test (Binax Now Filariasis card test, ICT) results was evaluated during a field survey in the Republic of Congo. One hundred and thirty-four (134) of 774 tests (17.3%) were clearly positive and were scored 1, 2, or 3; and 11 (1.4%) had questionable results. Wuchereria bancrofti microfilariae (mf) were detected in 41 of those 133 individuals with an ICT test score ≥ 1 who also had a night blood smear; none of the 11 individuals with questionable ICT results harbored night mf. Cuzick's test showed a significant trend for higher microfilarial densities in groups with higher ICT scores (P < 0.001). The ICT scores were also significantly correlated with blood mf counts. Because filarial antigen levels provide an indication of adult worm infection intensity, our results suggest that semi-quantitative reading of the ICT may be useful for grading the intensity of filarial infections in individuals and populations. PMID:24019435

  13. Evaluation of a large-scale quantitative respirator-fit testing program for healthcare workers: survey results.

    PubMed

    Wilkinson, Irene J; Pisaniello, Dino; Ahmad, Junaid; Edwards, Suzanne

    2010-09-01

    To present the evaluation of a large-scale quantitative respirator-fit testing program. Concurrent questionnaire survey of fit testers and test subjects. Ambulatory care, home nursing care, and acute care hospitals across South Australia. Quantitative facial-fit testing was performed with TSI PortaCount instruments for healthcare workers (HCWs) who wore 5 different models of a disposable P2 (N95-equivalent) respirator. The questionnaire included questions about the HCW's age, sex, race, occupational category, main area of work, smoking status, facial characteristics, prior training and experience in use of respiratory masks, and number of attempts to obtain a respirator fit. A total of 6,160 HCWs were successfully fitted during the period from January through July 2007. Of the 4,472 HCWs who responded to the questionnaire and were successfully fitted, 3,707 (82.9%) were successfully fitted with the first tested respirator, 551 (12.3%) required testing with a second model, and 214 (4.8%) required 3 or more tests. We noted an increased pass rate on the first attempt over time. Asians (excluding those from South and Central Asia) had the highest failure rate (16.3% [45 of 276 Asian HCWs were unsuccessfully fitted]), and whites had the lowest (9.8% [426 of 4,338 white HCWs]). Race was highly correlated with facial shape. Among occupational groups, doctors had the highest failure rate (13.4% [81 of 604 doctors]), but they also had the highest proportion of Asians. Prior education and/or training in respirator use were not associated with a higher pass rate. Certain facial characteristics were associated with higher or lower pass rates with regard to fit testing, and fit testers were able to select a suitable respirator on the basis of a visual assessment in the majority of cases. For the fit tester, training and experience were important factors; however, for the HCW being fitted, prior experience in respirator use was not an important factor.

  14. International Standards and Reference Materials for Quantitative Molecular Infectious Disease Testing

    PubMed Central

    Madej, Roberta M.; Davis, Jack; Holden, Marcia J.; Kwang, Stan; Labourier, Emmanuel; Schneider, George J.

    2010-01-01

    The utility of quantitative molecular diagnostics for patient management depends on the ability to relate patient results to prior results or to absolute values in clinical practice guidelines. To do this, those results need to be comparable across time and methods, either by producing the same value across methods and test versions or by using reliable and stable conversions. Universally available standards and reference materials specific to quantitative molecular technologies are critical to this process but are few in number. This review describes recent history in the establishment of international standards for nucleic acid test development, organizations involved in current efforts, and future issues and initiatives. PMID:20075208

  15. Simulated linear test applied to quantitative proteomics.

    PubMed

    Pham, T V; Jimenez, C R

    2016-09-01

    Omics studies aim to find significant changes due to biological or functional perturbation. However, gene and protein expression profiling experiments contain inherent technical variation. In discovery proteomics studies where the number of samples is typically small, technical variation plays an important role because it contributes considerably to the observed variation. Previous methods place both technical and biological variations in tightly integrated mathematical models that are difficult to adapt for different technological platforms. Our aim is to derive a statistical framework that allows the inclusion of a wide range of technical variability. We introduce a new method called the simulated linear test, or the s-test, that is easy to implement and easy to adapt for different models of technical variation. It generates virtual data points from the observed values according to a pre-defined technical distribution and subsequently employs linear modeling for significance analysis. We demonstrate the flexibility of the proposed approach by deriving a new significance test for quantitative discovery proteomics for which missing values have been a major issue for traditional methods such as the t-test. We evaluate the result on two label-free (phospho) proteomics datasets based on ion-intensity quantitation. Available at http://www.oncoproteomics.nl/software/stest.html : t.pham@vumc.nl. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  16. Assessment of and standardization for quantitative nondestructive test

    NASA Technical Reports Server (NTRS)

    Neuschaefer, R. W.; Beal, J. B.

    1972-01-01

    Present capabilities and limitations of nondestructive testing (NDT) as applied to aerospace structures during design, development, production, and operational phases are assessed. It will help determine what useful structural quantitative and qualitative data may be provided from raw materials to vehicle refurbishment. This assessment considers metal alloys systems and bonded composites presently applied in active NASA programs or strong contenders for future use. Quantitative and qualitative data has been summarized from recent literature, and in-house information, and presented along with a description of those structures or standards where the information was obtained. Examples, in tabular form, of NDT technique capabilities and limitations have been provided. NDT techniques discussed and assessed were radiography, ultrasonics, penetrants, thermal, acoustic, and electromagnetic. Quantitative data is sparse; therefore, obtaining statistically reliable flaw detection data must be strongly emphasized. The new requirements for reusable space vehicles have resulted in highly efficient design concepts operating in severe environments. This increases the need for quantitative NDT evaluation of selected structural components, the end item structure, and during refurbishment operations.

  17. Prototype ultrasonic instrument for quantitative testing

    NASA Technical Reports Server (NTRS)

    Lynnworth, L. C.; Dubois, J. L.; Kranz, P. R.

    1972-01-01

    A prototype ultrasonic instrument has been designed and developed for quantitative testing. The complete delivered instrument consists of a pulser/receiver which plugs into a standard oscilloscope, an rf power amplifier, a standard decade oscillator, and a set of broadband transducers for typical use at 1, 2, 5 and 10 MHz. The system provides for its own calibration, and on the oscilloscope, presents a quantitative (digital) indication of time base and sensitivity scale factors and some measurement data.

  18. Quantitative Accelerated Life Testing of MEMS Accelerometers

    PubMed Central

    Bâzu, Marius; Gălăţeanu, Lucian; Ilian, Virgil Emil; Loicq, Jerome; Habraken, Serge; Collette, Jean-Paul

    2007-01-01

    Quantitative Accelerated Life Testing (QALT) is a solution for assessing the reliability of Micro Electro Mechanical Systems (MEMS). A procedure for QALT is shown in this paper and an attempt to assess the reliability level for a batch of MEMS accelerometers is reported. The testing plan is application-driven and contains combined tests: thermal (high temperature) and mechanical stress. Two variants of mechanical stress are used: vibration (at a fixed frequency) and tilting. Original equipment for testing at tilting and high temperature is used. Tilting is appropriate as application-driven stress, because the tilt movement is a natural environment for devices used for automotive and aerospace applications. Also, tilting is used by MEMS accelerometers for anti-theft systems. The test results demonstrated the excellent reliability of the studied devices, the failure rate in the “worst case” being smaller than 10-7h-1. PMID:28903265

  19. Exhaust-System Leak Test : Quantitative Procedure

    DOT National Transportation Integrated Search

    1974-01-01

    A quantitative, periodic motor vehicle safety-inspection test for determining the leakage rate of engine exhaust from an automotive exhaust system was investigated. Two technical approaches were evaluated, and the better one was selected for developm...

  20. Quantitation of a slide test (Monotest) for infectious mononucleosis

    PubMed Central

    Carter, P. Kenneth; Schoen, Irwin; Miyahira, Teru

    1970-01-01

    A slide test for infectious mononucleosis using formalinized horse erythrocytes (Monotest2) was quantitated and compared with standard differential heterophile (Davidsohn) titres performed on the same specimens. The Monotest titre parallels the standard presumptive heterophile (antisheep cell) titre in the degree of elevation, with a ratio of Monotest to heterophile titre of approximately 1 to 56. The simplicity of the quantitative slide test recommends it as a routine test for infectious mononucleosis. PMID:5530641

  1. Preliminary research on eddy current bobbin quantitative test for heat exchange tube in nuclear power plant

    NASA Astrophysics Data System (ADS)

    Qi, Pan; Shao, Wenbin; Liao, Shusheng

    2016-02-01

    For quantitative defects detection research on heat transfer tube in nuclear power plants (NPP), two parts of work are carried out based on the crack as the main research objects. (1) Production optimization of calibration tube. Firstly, ASME, RSEM and homemade crack calibration tubes are applied to quantitatively analyze the defects depth on other designed crack test tubes, and then the judgment with quantitative results under crack calibration tube with more accuracy is given. Base on that, weight analysis of influence factors for crack depth quantitative test such as crack orientation, length, volume and so on can be undertaken, which will optimize manufacture technology of calibration tubes. (2) Quantitative optimization of crack depth. Neural network model with multi-calibration curve adopted to optimize natural crack test depth generated in in-service tubes shows preliminary ability to improve quantitative accuracy.

  2. Indirect scaling methods for testing quantitative emotion theories.

    PubMed

    Junge, Martin; Reisenzein, Rainer

    2013-01-01

    Two studies investigated the utility of indirect scaling methods, based on graded pair comparisons, for the testing of quantitative emotion theories. In Study 1, we measured the intensity of relief and disappointment caused by lottery outcomes, and in Study 2, the intensity of disgust evoked by pictures, using both direct intensity ratings and graded pair comparisons. The stimuli were systematically constructed to reflect variables expected to influence the intensity of the emotions according to theoretical models of relief/disappointment and disgust, respectively. Two probabilistic scaling methods were used to estimate scale values from the pair comparison judgements: Additive functional measurement (AFM) and maximum likelihood difference scaling (MLDS). The emotion models were fitted to the direct and indirect intensity measurements using nonlinear regression (Study 1) and analysis of variance (Study 2). Both studies found substantially improved fits of the emotion models for the indirectly determined emotion intensities, with their advantage being evident particularly at the level of individual participants. The results suggest that indirect scaling methods yield more precise measurements of emotion intensity than rating scales and thereby provide stronger tests of emotion theories in general and quantitative emotion theories in particular.

  3. A prototype tap test imaging system: Initial field test results

    NASA Astrophysics Data System (ADS)

    Peters, J. J.; Barnard, D. J.; Hudelson, N. A.; Simpson, T. S.; Hsu, D. K.

    2000-05-01

    This paper describes a simple, field-worthy tap test imaging system that gives quantitative information about the size, shape, and severity of defects and damages. The system consists of an accelerometer, electronic circuits for conditioning the signal and measuring the impact duration, a laptop PC and data acquisition and processing software. The images are generated manually by tapping on a grid printed on a plastic sheet laid over the part's surface. A mechanized scanner is currently under development. The prototype has produced images for a variety of aircraft composite and metal honeycomb structures containing flaws, damages, and repairs. Images of the local contact stiffness, deduced from the impact duration using a spring model, revealed quantitatively the stiffness reduction due to flaws and damages, as well as the stiffness enhancement due to substructures. The system has been field tested on commercial and military aircraft as well as rotor blades and engine decks on helicopters. Field test results will be shown and the operation of the system will be demonstrated.—This material is based upon work supported by the Federal Aviation Administration under Contract #DTFA03-98-D-00008, Delivery Order No. IA016 and performed at Iowa State University's Center for NDE as part of the Center for Aviation Systems Reliability program.

  4. Effects of normalization on quantitative traits in association test

    PubMed Central

    2009-01-01

    Background Quantitative trait loci analysis assumes that the trait is normally distributed. In reality, this is often not observed and one strategy is to transform the trait. However, it is not clear how much normality is required and which transformation works best in association studies. Results We performed simulations on four types of common quantitative traits to evaluate the effects of normalization using the logarithm, Box-Cox, and rank-based transformations. The impact of sample size and genetic effects on normalization is also investigated. Our results show that rank-based transformation gives generally the best and consistent performance in identifying the causal polymorphism and ranking it highly in association tests, with a slight increase in false positive rate. Conclusion For small sample size or genetic effects, the improvement in sensitivity for rank transformation outweighs the slight increase in false positive rate. However, for large sample size and genetic effects, normalization may not be necessary since the increase in sensitivity is relatively modest. PMID:20003414

  5. Comparative Evaluation of Quantitative Test Methods for Gases on a Hard Surface

    DTIC Science & Technology

    2017-02-01

    COMPARATIVE EVALUATION OF QUANTITATIVE TEST METHODS FOR GASES ON A HARD SURFACE ECBC-TR-1426 Vipin Rastogi...1 COMPARATIVE EVALUATION OF QUANTITATIVE TEST METHODS FOR GASES ON A HARD SURFACE 1. INTRODUCTION Members of the U.S. Environmental...Generator 4 2.4 Experimental Design Each quantitative method was performed three times on three consecutive days. For the CD runs, three

  6. Comparison of Quantitative Antifungal Testing Methods for Textile Fabrics.

    PubMed

    Imoto, Yasuo; Seino, Satoshi; Nakagawa, Takashi; Yamamoto, Takao A

    2017-01-01

     Quantitative antifungal testing methods for textile fabrics under growth-supportive conditions were studied. Fungal growth activities on unfinished textile fabrics and textile fabrics modified with Ag nanoparticles were investigated using the colony counting method and the luminescence method. Morphological changes of the fungi during incubation were investigated by microscopic observation. Comparison of the results indicated that the fungal growth activity values obtained with the colony counting method depended on the morphological state of the fungi on textile fabrics, whereas those obtained with the luminescence method did not. Our findings indicated that unique characteristics of each testing method must be taken into account for the proper evaluation of antifungal activity.

  7. Quantitative MR imaging in fracture dating--Initial results.

    PubMed

    Baron, Katharina; Neumayer, Bernhard; Widek, Thomas; Schick, Fritz; Scheicher, Sylvia; Hassler, Eva; Scheurer, Eva

    2016-04-01

    For exact age determinations of bone fractures in a forensic context (e.g. in cases of child abuse) improved knowledge of the time course of the healing process and use of non-invasive modern imaging technology is of high importance. To date, fracture dating is based on radiographic methods by determining the callus status and thereby relying on an expert's experience. As a novel approach, this study aims to investigate the applicability of magnetic resonance imaging (MRI) for bone fracture dating by systematically investigating time-resolved changes in quantitative MR characteristics after a fracture event. Prior to investigating fracture healing in children, adults were examined for this study in order to test the methodology for this application. Altogether, 31 MR examinations in 17 subjects (♀: 11 ♂: 6; median age 34 ± 15 y, scanned 1-5 times over a period of up to 200 days after the fracture event) were performed on a clinical 3T MR scanner (TimTrio, Siemens AG, Germany). All subjects were treated conservatively for a fracture in either a long bone or in the collar bone. Both, qualitative and quantitative MR measurements were performed in all subjects. MR sequences for a quantitative measurement of relaxation times T1 and T2 in the fracture gap and musculature were applied. Maps of quantitative MR parameters T1, T2, and magnetisation transfer ratio (MTR) were calculated and evaluated by investigating changes over time in the fractured area by defined ROIs. Additionally, muscle areas were examined as reference regions to validate this approach. Quantitative evaluation of 23 MR data sets (12 test subjects, ♀: 7 ♂: 5) showed an initial peak in T1 values in the fractured area (T1=1895 ± 607 ms), which decreased over time to a value of 1094 ± 182 ms (200 days after the fracture event). T2 values also peaked for early-stage fractures (T2=115 ± 80 ms) and decreased to 73 ± 33 ms within 21 days after the fracture event. After that time point, no

  8. Metrologies for quantitative nanomechanical testing and quality control in semiconductor manufacturing

    NASA Astrophysics Data System (ADS)

    Pratt, Jon R.; Kramar, John A.; Newell, David B.; Smith, Douglas T.

    2005-05-01

    If nanomechanical testing is to evolve into a tool for process and quality control in semiconductor fabrication, great advances in throughput, repeatability, and accuracy of the associated instruments and measurements will be required. A recent grant awarded by the NIST Advanced Technology Program seeks to address the throughput issue by developing a high-speed AFM-based platform for quantitative nanomechanical measurements. The following paper speaks to the issue of quantitative accuracy by presenting an overview of various standards and techniques under development at NIST and other national metrology institutes (NMIs) that can provide a metrological basis for nanomechanical testing. The infrastructure we describe places firm emphasis on traceability to the International System of Units, paving the way for truly quantitative, rather than qualitative, physical property testing.

  9. Quantitative impact characterization of aeronautical CFRP materials with non-destructive testing methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kiefel, Denis, E-mail: Denis.Kiefel@airbus.com, E-mail: Rainer.Stoessel@airbus.com; Stoessel, Rainer, E-mail: Denis.Kiefel@airbus.com, E-mail: Rainer.Stoessel@airbus.com; Grosse, Christian, E-mail: Grosse@tum.de

    2015-03-31

    In recent years, an increasing number of safety-relevant structures are designed and manufactured from carbon fiber reinforced polymers (CFRP) in order to reduce weight of airplanes by taking the advantage of their specific strength into account. Non-destructive testing (NDT) methods for quantitative defect analysis of damages are liquid- or air-coupled ultrasonic testing (UT), phased array ultrasonic techniques, and active thermography (IR). The advantage of these testing methods is the applicability on large areas. However, their quantitative information is often limited on impact localization and size. In addition to these techniques, Airbus Group Innovations operates a micro x-ray computed tomography (μ-XCT)more » system, which was developed for CFRP characterization. It is an open system which allows different kinds of acquisition, reconstruction, and data evaluation. One main advantage of this μ-XCT system is its high resolution with 3-dimensional analysis and visualization opportunities, which enables to gain important quantitative information for composite part design and stress analysis. Within this study, different NDT methods will be compared at CFRP samples with specified artificial impact damages. The results can be used to select the most suitable NDT-method for specific application cases. Furthermore, novel evaluation and visualization methods for impact analyzes are developed and will be presented.« less

  10. A Multicenter Trial of the Proficiency of Smart Quantitative Sensation Tests

    PubMed Central

    Dyck, Peter J.; Argyros, Barbara; Russell, James W.; Gahnstrom, Linde E.; Nalepa, Susan; Albers, James W.; Lodermeier, Karen A.; Zafft, Andrew J.; Dyck, P. James B.; Klein, Christopher J.; Litchy, William J.; Davies, Jenny L.; Carter, Rickey E.; Melton, L. Joseph

    2014-01-01

    Introduction We assessed proficiency (accuracy and intra- and inter-test reproducibility) of smart quantitative sensation tests (smart QSTs) in subjects without and with diabetic polyneuropathy (DSPN). Methods Technologists from 3 medical centers using different but identical QSTs assessed independently 6 modalities of sensation of foot (or leg) twice in patients without (n = 6) and with (n = 6) DSPN using smart computer assisted QSTs. Results Low rates of test abnormalities were observed in health and high rates in DSPN. Very high intra-class correlations were obtained between continuous measures of QSTs and neuropathy signs, symptoms, or nerve conductions (NCs). No significant intra- or inter-test differences were observed. Discussion These results provide proof of concept that smart QSTs provide accurate assessment of sensation loss without intra- or inter-test differences useful for multicenter trials. Smart technology makes possible efficient testing of body surface area sensation loss in symmetric length-dependent sensorimotor polyneuropathies. PMID:23929701

  11. An autoanalyzer test for the quantitation of platelet-associated IgG

    NASA Technical Reports Server (NTRS)

    Levitan, Nathan; Teno, Richard A.; Szymanski, Irma O.

    1986-01-01

    A new quantitative antiglobulin consumption (QAC) test for the measurement of platelet-associated IgG is described. In this test washed platelets are incubated with anti-IgG at a final dilution of 1:2 million. The unneutralized fraction of anti-IgG remaining in solution is then measured with an Autoanalyzer and soluble IgG is used for calibration. The dose-response curves depicting the percent neutralization of anti-IgG by platelets and by soluble IgG were compared in detail and found to be nearly identical, indicating that platelet-associated IgG can be accurately quantitated by this method. The mean IgG values were 2287 molecules/platelet for normal adults and 38,112 molecules/platelet for ITP patients. The Autoanalyzer QAC test is a sensitive and reproducible assay for the quantitation of platelet-associated IgG.

  12. Germicidal Activity against Carbapenem/Colistin-Resistant Enterobacteriaceae Using a Quantitative Carrier Test Method.

    PubMed

    Kanamori, Hajime; Rutala, William A; Gergen, Maria F; Sickbert-Bennett, Emily E; Weber, David J

    2018-05-07

    Susceptibility to germicides for carbapenem/colistin-resistant Enterobacteriaceae is poorly described. We investigated the efficacy of multiple germicides against these emerging antibiotic-resistant pathogens using the disc-based quantitative carrier test method that can produce results more similar to those encountered in healthcare settings than a suspension test. Our study results demonstrated that germicides commonly used in healthcare facilities likely will be effective against carbapenem/colistin-resistant Enterobacteriaceae when used appropriately in healthcare facilities. Copyright © 2018 American Society for Microbiology.

  13. Selecting the most appropriate inferential statistical test for your quantitative research study.

    PubMed

    Bettany-Saltikov, Josette; Whittaker, Victoria Jane

    2014-06-01

    To discuss the issues and processes relating to the selection of the most appropriate statistical test. A review of the basic research concepts together with a number of clinical scenarios is used to illustrate this. Quantitative nursing research generally features the use of empirical data which necessitates the selection of both descriptive and statistical tests. Different types of research questions can be answered by different types of research designs, which in turn need to be matched to a specific statistical test(s). Discursive paper. This paper discusses the issues relating to the selection of the most appropriate statistical test and makes some recommendations as to how these might be dealt with. When conducting empirical quantitative studies, a number of key issues need to be considered. Considerations for selecting the most appropriate statistical tests are discussed and flow charts provided to facilitate this process. When nursing clinicians and researchers conduct quantitative research studies, it is crucial that the most appropriate statistical test is selected to enable valid conclusions to be made. © 2013 John Wiley & Sons Ltd.

  14. The predictive value of quantitative fibronectin testing in combination with cervical length measurement in symptomatic women.

    PubMed

    Bruijn, Merel M C; Kamphuis, Esme I; Hoesli, Irene M; Martinez de Tejada, Begoña; Loccufier, Anne R; Kühnert, Maritta; Helmer, Hanns; Franz, Marie; Porath, Martina M; Oudijk, Martijn A; Jacquemyn, Yves; Schulzke, Sven M; Vetter, Grit; Hoste, Griet; Vis, Jolande Y; Kok, Marjolein; Mol, Ben W J; van Baaren, Gert-Jan

    2016-12-01

    The combination of the qualitative fetal fibronectin test and cervical length measurement has a high negative predictive value for preterm birth within 7 days; however, positive prediction is poor. A new bedside quantitative fetal fibronectin test showed potential additional value over the conventional qualitative test, but there is limited evidence on the combination with cervical length measurement. The purpose of this study was to compare quantitative fetal fibronectin and qualitative fetal fibronectin testing in the prediction of spontaneous preterm birth within 7 days in symptomatic women who undergo cervical length measurement. We performed a European multicenter cohort study in 10 perinatal centers in 5 countries. Women between 24 and 34 weeks of gestation with signs of active labor and intact membranes underwent quantitative fibronectin testing and cervical length measurement. We assessed the risk of preterm birth within 7 days in predefined strata based on fibronectin concentration and cervical length. Of 455 women who were included in the study, 48 women (11%) delivered within 7 days. A combination of cervical length and qualitative fibronectin resulted in the identification of 246 women who were at low risk: 164 women with a cervix between 15 and 30 mm and a negative fibronectin test (<50 ng/mL; preterm birth rate, 2%) and 82 women with a cervix at >30 mm (preterm birth rate, 2%). Use of quantitative fibronectin alone resulted in a predicted risk of preterm birth within 7 days that ranged from 2% in the group with the lowest fibronectin level (<10 ng/mL) to 38% in the group with the highest fibronectin level (>500 ng/mL), with similar accuracy as that of the combination of cervical length and qualitative fibronectin. Combining cervical length and quantitative fibronectin resulted in the identification of an additional 19 women at low risk (preterm birth rate, 5%), using a threshold of 10 ng/mL in women with a cervix at <15 mm, and 6 women at high risk

  15. Testing the Protestant Ethic Thesis with Quantitative Historical Data: A Research Note

    ERIC Educational Resources Information Center

    Sanderson, Stephen K.; Abrutyn, Seth B.; Proctor, Kristopher R.

    2011-01-01

    We provide a test of the thesis that Protestantism influenced the development of modern capitalism by using quantitative data from 1500 through 1870. Results show that during this period the percentage of a country's population that is Protestant is unrelated to both its level of per capita GDP and the average rate of its annual growth in per…

  16. Diagnosing acute HIV infection: The performance of quantitative HIV-1 RNA testing (viral load) in the 2014 laboratory testing algorithm.

    PubMed

    Wu, Hsiu; Cohen, Stephanie E; Westheimer, Emily; Gay, Cynthia L; Hall, Laura; Rose, Charles; Hightow-Weidman, Lisa B; Gose, Severin; Fu, Jie; Peters, Philip J

    2017-08-01

    New recommendations for laboratory diagnosis of HIV infection in the United States were published in 2014. The updated testing algorithm includes a qualitative HIV-1 RNA assay to resolve discordant immunoassay results and to identify acute HIV-1 infection (AHI). The qualitative HIV-1 RNA assay is not widely available; therefore, we evaluated the performance of a more widely available quantitative HIV-1 RNA assay, viral load, for diagnosing AHI. We determined that quantitative viral loads consistently distinguished AHI from a false-positive immunoassay result. Among 100 study participants with AHI and a viral load result, the estimated geometric mean viral load was 1,377,793copies/mL. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Connecting qualitative observation and quantitative measurement for enhancing quantitative literacy in plant anatomy course

    NASA Astrophysics Data System (ADS)

    Nuraeni, E.; Rahmat, A.

    2018-05-01

    Forming of cognitive schemes of plant anatomy concepts is performed by processing of qualitative and quantitative data obtained from microscopic observations. To enhancing student’s quantitative literacy, strategy of plant anatomy course was modified by adding the task to analyze quantitative data produced by quantitative measurement of plant anatomy guided by material course. Participant in this study was 24 biology students and 35 biology education students. Quantitative Literacy test, complex thinking in plant anatomy test and questioner used to evaluate the course. Quantitative literacy capability data was collected by quantitative literacy test with the rubric from the Association of American Colleges and Universities, Complex thinking in plant anatomy by test according to Marzano and questioner. Quantitative literacy data are categorized according to modified Rhodes and Finley categories. The results showed that quantitative literacy of biology education students is better than biology students.

  18. Quantitative Accelerated Life Testing of MEMS Accelerometers.

    PubMed

    Bâzu, Marius; Gălăţeanu, Lucian; Ilian, Virgil Emil; Loicq, Jerome; Habraken, Serge; Collette, Jean-Paul

    2007-11-20

    Quantitative Accelerated Life Testing (QALT) is a solution for assessing thereliability of Micro Electro Mechanical Systems (MEMS). A procedure for QALT is shownin this paper and an attempt to assess the reliability level for a batch of MEMSaccelerometers is reported. The testing plan is application-driven and contains combinedtests: thermal (high temperature) and mechanical stress. Two variants of mechanical stressare used: vibration (at a fixed frequency) and tilting. Original equipment for testing at tiltingand high temperature is used. Tilting is appropriate as application-driven stress, because thetilt movement is a natural environment for devices used for automotive and aerospaceapplications. Also, tilting is used by MEMS accelerometers for anti-theft systems. The testresults demonstrated the excellent reliability of the studied devices, the failure rate in the"worst case" being smaller than 10 -7 h -1 .

  19. Quantitative somatosensory testing of the penis: optimizing the clinical neurological examination.

    PubMed

    Bleustein, Clifford B; Eckholdt, Haftan; Arezzo, Joseph C; Melman, Arnold

    2003-06-01

    Quantitative somatosensory testing, including vibration, pressure, spatial perception and thermal thresholds of the penis, has demonstrated neuropathy in patients with a history of erectile dysfunction of all etiologies. We evaluated which measurement of neurological function of the penis was best at predicting erectile dysfunction and examined the impact of location on the penis for quantitative somatosensory testing measurements. A total of 107 patients were evaluated. All patients were required to complete the erectile function domain of the International Index of Erectile Function (IIEF) questionnaire, of whom 24 had no complaints of erectile dysfunction and scored within the "normal" range on the IIEF. Patients were subsequently tested on ventral middle penile shaft, proximal dorsal midline penile shaft and glans penis (with foreskin retracted) for vibration, pressure, spatial perception, and warm and cold thermal thresholds. Mixed models repeated measures analysis of variance controlling for age, diabetes and hypertension revealed that method of measurement (quantitative somatosensory testing) was predictive of IIEF score (F = 209, df = 4,1315, p <0.001), while site of measurement on the penis was not. To determine the best method of measurement, we used hierarchical regression, which revealed that warm temperature was the best predictor of erectile dysfunction with pseudo R(2) = 0.19, p <0.0007. There was no significant improvement in predicting erectile dysfunction when another test was added. Using 37C and greater as the warm thermal threshold yielded a sensitivity of 88.5%, specificity 70.0% and positive predictive value 85.5%. Quantitative somatosensory testing using warm thermal threshold measurements taken at the glans penis can be used alone to assess the neurological status of the penis. Warm thermal thresholds alone offer a quick, noninvasive accurate method of evaluating penile neuropathy in an office setting.

  20. CONFOCAL MICROSCOPY SYSTEM PERFORMANCE: QA TESTS, QUANTITATION AND SPECTROSCOPY

    EPA Science Inventory

    Confocal Microscopy System Performance: QA tests, Quantitation and Spectroscopy.

    Robert M. Zucker 1 and Jeremy M. Lerner 2,
    1Reproductive Toxicology Division, National Health and Environmental Effects Research Laboratory, Office of Research Development, U.S. Environmen...

  1. QDIRT: Quantitative Direct and Indirect Testing of Sudomotor Function

    PubMed Central

    Gibbons, Christopher H.; Illigens, Ben MW; Centi, Justin; Freeman, Roy

    2011-01-01

    Objective To develop a novel assessment of sudomotor function. Background Post-ganglionic sudomotor function is currently evaluated using quantitative sudomotor axon reflex testing (QSART) or silicone impressions. We hypothesize that high-resolution digital photography has advanced sufficiently to allow quantitative direct and indirect testing of sudomotor function (QDIRT) with spatial and temporal resolution comparable to these techniques. Methods Sweating in 10 humans was stimulated on both forearms by iontophoresis of 10% acetylcholine. Silicone impressions were made and topical indicator dyes were digitally photographed every 15 seconds for 7 minutes after iontophoresis. Sweat droplets were quantified by size, location and percent surface area. Each test was repeated 8 times in each subject on alternating arms over 2 months. Another 10 subjects had silicone impressions, QDIRT and QSART performed on the dorsum of the right foot. Results The percent area of sweat photographically imaged correlated with silicone impressions at 5 minutes on the forearm (r = 0.92, p<0.01) and dorsal foot (r=0.85, p<0.01). The number of sweat droplets assessed with QDIRT correlated with the silicone impression although the droplet number was lower (162±28 vs. 341±56, p<0.01; r =0.83, p<0.01). QDIRT and QSART sudomotor assessments measured at the dorsum of the foot correlated (sweat response (r=0.63, p<0.05) and sweat onset latency (r=0.52, p<0.05). Conclusions QDIRT measured both the direct and indirect sudomotor response with spatial resolution similar to silicone impressions, and with temporal resolution that is similar to QSART. QDIRT provides a novel tool for the evaluation of post-ganglionic sudomotor function. PMID:18541883

  2. Comparative Application of PLS and PCR Methods to Simultaneous Quantitative Estimation and Simultaneous Dissolution Test of Zidovudine - Lamivudine Tablets.

    PubMed

    Üstündağ, Özgür; Dinç, Erdal; Özdemir, Nurten; Tilkan, M Günseli

    2015-01-01

    In the development strategies of new drug products and generic drug products, the simultaneous in-vitro dissolution behavior of oral dosage formulations is the most important indication for the quantitative estimation of efficiency and biopharmaceutical characteristics of drug substances. This is to force the related field's scientists to improve very powerful analytical methods to get more reliable, precise and accurate results in the quantitative analysis and dissolution testing of drug formulations. In this context, two new chemometric tools, partial least squares (PLS) and principal component regression (PCR) were improved for the simultaneous quantitative estimation and dissolution testing of zidovudine (ZID) and lamivudine (LAM) in a tablet dosage form. The results obtained in this study strongly encourage us to use them for the quality control, the routine analysis and the dissolution test of the marketing tablets containing ZID and LAM drugs.

  3. Proficiency testing as a basis for estimating uncertainty of measurement: application to forensic alcohol and toxicology quantitations.

    PubMed

    Wallace, Jack

    2010-05-01

    While forensic laboratories will soon be required to estimate uncertainties of measurement for those quantitations reported to the end users of the information, the procedures for estimating this have been little discussed in the forensic literature. This article illustrates how proficiency test results provide the basis for estimating uncertainties in three instances: (i) For breath alcohol analyzers the interlaboratory precision is taken as a direct measure of uncertainty. This approach applies when the number of proficiency tests is small. (ii) For blood alcohol, the uncertainty is calculated from the differences between the laboratory's proficiency testing results and the mean quantitations determined by the participants; this approach applies when the laboratory has participated in a large number of tests. (iii) For toxicology, either of these approaches is useful for estimating comparability between laboratories, but not for estimating absolute accuracy. It is seen that data from proficiency tests enable estimates of uncertainty that are empirical, simple, thorough, and applicable to a wide range of concentrations.

  4. Predictive values of semi-quantitative procalcitonin test and common biomarkers for the clinical outcomes of community-acquired pneumonia.

    PubMed

    Ugajin, Motoi; Yamaki, Kenichi; Hirasawa, Natsuko; Yagi, Takeo

    2014-04-01

    The semi-quantitative serum procalcitonin test (Brahms PCT-Q) is available conveniently in clinical practice. However, there are few data on the relationship between results for this semi-quantitative procalcitonin test and clinical outcomes of community-acquired pneumonia (CAP). We investigated the usefulness of this procalcitonin test for predicting the clinical outcomes of CAP in comparison with severity scoring systems and the blood urea nitrogen/serum albumin (B/A) ratio, which has been reported to be a simple but reliable prognostic indicator in our prior CAP study. This retrospective study included data from subjects who were hospitalized for CAP from August 2010 through October 2012 and who were administered the semi-quantitative serum procalcitonin test on admission. The demographic characteristics; laboratory biomarkers; microbiological test results; Pneumonia Severity Index scores; confusion, urea nitrogen, breathing frequency, blood pressure, ≥ 65 years of age (CURB-65) scale scores; and age, dehydration, respiratory failure, orientation disturbance, pressure (A-DROP) scale scores on hospital admission were retrieved from their medical charts. The outcomes were mortality within 28 days of hospital admission and the need for intensive care. Of the 213 subjects with CAP who were enrolled in the study, 20 died within 28 days of hospital admission, and 32 required intensive care. Mortality did not differ significantly among subjects with different semi-quantitative serum procalcitonin levels; however, subjects with serum procalcitonin levels ≥ 10.0 ng/mL were more likely to require intensive care than those with lower levels (P < .001). The elevation of semi-quantitative serum procalcitonin levels was more frequently observed in subjects with proven etiology, especially pneumococcal pneumonia. Using the receiver operating characteristic curves for mortality, the area under the curve was 0.86 for Pneumonia Severity Index class, 0.81 for B/A ratio, 0

  5. Quantitative Sensory Testing in Adults with Autism Spectrum Disorders

    ERIC Educational Resources Information Center

    Fründt, Odette; Grashorn, Wiebke; Schöttle, Daniel; Peiker, Ina; David, Nicole; Engel, Andreas K.; Forkmann, Katarina; Wrobel, Nathalie; Münchau, Alexander; Bingel, Ulrike

    2017-01-01

    Altered sensory perception has been found in patients with autism spectrum disorders (ASD) and might be related to aberrant sensory perception thresholds. We used the well-established, standardized Quantitative sensory testing (QST) protocol of the German Research Network on Neuropathic Pain to investigate 13 somatosensory parameters including…

  6. Multicenter trial of the proficiency of smart quantitative sensation tests.

    PubMed

    Dyck, Peter J; Argyros, Barbara; Russell, James W; Gahnstrom, Linde E; Nalepa, Susan; Albers, James W; Lodermeier, Karen A; Zafft, Andrew J; Dyck, P James B; Klein, Christopher J; Litchy, William J; Davies, Jenny L; Carter, Rickey E; Melton, L Joseph

    2014-05-01

    We assessed proficiency (accuracy and intra- and intertest reproducibility) of smart quantitative sensation tests (smart QSTs) in subjects without and with diabetic sensorimotor polyneuropathy (DSPN). Technologists from 3 medical centers using different but identical QSTs independently assessed 6 modalities of sensation of the foot (or leg) twice in patients without (n = 6) and with (n = 6) DSPN using smart computer assisted QSTs. Low rates of test abnormalities were observed in health and high rates in DSPN. Very high intraclass correlations were obtained between continuous measures of QSTs and neuropathy signs, symptoms, or nerve conductions (NCs). No significant intra- or intertest differences were observed. These results provide proof of concept that smart QSTs provide accurate assessment of sensation loss without intra- or intertest differences useful for multicenter trials. Smart technology makes possible efficient testing of body surface area sensation loss in symmetric length-dependent sensorimotor polyneuropathies. Copyright © 2013 Wiley Periodicals, Inc.

  7. Comparison of two quantitative fit-test methods using N95 filtering facepiece respirators.

    PubMed

    Sietsema, Margaret; Brosseau, Lisa M

    2016-08-01

    Current regulations require annual fit testing before an employee can wear a respirator during work activities. The goal of this research is to determine whether respirator fit measured with two TSI Portacount instruments simultaneously sampling ambient particle concentrations inside and outside of the respirator facepiece is similar to fit measured during an ambient aerosol condensation nuclei counter quantitative fit test. Sixteen subjects (ten female; six male) were recruited for a range of facial sizes. Each subject donned an N95 filtering facepiece respirator, completed two fit tests in random order (ambient aerosol condensation nuclei counter quantitative fit test and two-instrument real-time fit test) without removing or adjusting the respirator between tests. Fit tests were compared using Spearman's rank correlation coefficients. The real-time two-instrument method fit factors were similar to those measured with the single-instrument quantitative fit test. The first four exercises were highly correlated (r > 0.7) between the two protocols. Respirator fit was altered during the talking or grimace exercise, both of which involve facial movements that could dislodge the facepiece. Our analyses suggest that the new real-time two-instrument methodology can be used in future studies to evaluate fit before and during work activities.

  8. Semi Quantitative MALDI TOF for Antimicrobial Susceptibility Testing in Staphylococcus aureus

    DTIC Science & Technology

    2017-08-31

    Semi- quantitative MALDI-TOF for antimicrobial susceptibility testing in Staphylococcus 1 aureus 2 3 4 Tucker Maxson,a Cheryl L. Taylor-Howell,a...Timothy D. Minoguea# 5 6 Diagnostic Systems Division, United States Army Medical Research Institute of Infectious 7 Disease, Fort Detrick, MD...USAa 8 9 Running Title: Quantitative MALDI for AST in S. aureus 10 #Address correspondence to Timothy D. Minogue, timothy.d.minogue.civ@mail.mil

  9. Reinventing the ames test as a quantitative lab that connects classical and molecular genetics.

    PubMed

    Goodson-Gregg, Nathan; De Stasio, Elizabeth A

    2009-01-01

    While many institutions use a version of the Ames test in the undergraduate genetics laboratory, students typically are not exposed to techniques or procedures beyond qualitative analysis of phenotypic reversion, thereby seriously limiting the scope of learning. We have extended the Ames test to include both quantitative analysis of reversion frequency and molecular analysis of revertant gene sequences. By giving students a role in designing their quantitative methods and analyses, students practice and apply quantitative skills. To help students connect classical and molecular genetic concepts and techniques, we report here procedures for characterizing the molecular lesions that confer a revertant phenotype. We suggest undertaking reversion of both missense and frameshift mutants to allow a more sophisticated molecular genetic analysis. These modifications and additions broaden the educational content of the traditional Ames test teaching laboratory, while simultaneously enhancing students' skills in experimental design, quantitative analysis, and data interpretation.

  10. Clinical neurophysiology and quantitative sensory testing in the investigation of orofacial pain and sensory function.

    PubMed

    Jääskeläinen, Satu K

    2004-01-01

    Chronic orofacial pain represents a diagnostic and treatment challenge for the clinician. Some conditions, such as atypical facial pain, still lack proper diagnostic criteria, and their etiology is not known. The recent development of neurophysiological methods and quantitative sensory testing for the examination of the trigeminal somatosensory system offers several tools for diagnostic and etiological investigation of orofacial pain. This review presents some of these techniques and the results of their application in studies on orofacial pain and sensory dysfunction. Clinical neurophysiological investigation has greater diagnostic accuracy and sensitivity than clinical examination in the detection of the neurogenic abnormalities of either peripheral or central origin that may underlie symptoms of orofacial pain and sensory dysfunction. Neurophysiological testing may also reveal trigeminal pathology when magnetic resonance imaging has failed to detect it, so these methods should be considered complementary to each other in the investigation of orofacial pain patients. The blink reflex, corneal reflex, jaw jerk, sensory neurography of the inferior alveolar nerve, and the recording of trigeminal somatosensory-evoked potentials with near-nerve stimulation have all proved to be sensitive and reliable in the detection of dysfunction of the myelinated sensory fibers of the trigeminal nerve or its central connections within the brainstem. With appropriately small thermodes, thermal quantitative sensory testing is useful for the detection of trigeminal small-fiber dysfunction (Adelta and C). In neuropathic conditions, it is most sensitive to lesions causing axonal injury. By combining different techniques for investigation of the trigeminal system, an accurate topographical diagnosis and profile of sensory fiber pathology can be determined. Neurophysiological and quantitative sensory tests have already highlighted some similarities among various orofacial pain conditions

  11. Structural fatigue test results for large wind turbine blade sections

    NASA Technical Reports Server (NTRS)

    Faddoul, J. R.; Sullivan, T. L.

    1982-01-01

    In order to provide quantitative information on the operating life capabilities of wind turbine rotor blade concepts for root-end load transfer, a series of cantilever beam fatigue tests was conducted. Fatigue tests were conducted on a laminated wood blade with bonded steel studs, a low cost steel spar (utility pole) with a welded flange, a utility pole with additional root-end thickness provided by a swaged collar, fiberglass spars with both bonded and nonbonded fittings, and, finally, an aluminum blade with a bolted steel fitting (Lockheed Mod-0 blade). Photographs, data, and conclusions for each of these tests are presented. In addition, the aluminum blade test results are compared to field failure information; these results provide evidence that the cantilever beam type of fatigue test is a satisfactory method for obtaining qualitative data on blade life expectancy and for identifying structurally underdesigned areas (hot spots).

  12. Simultaneous Quantitative Detection of Helicobacter Pylori Based on a Rapid and Sensitive Testing Platform using Quantum Dots-Labeled Immunochromatiographic Test Strips

    NASA Astrophysics Data System (ADS)

    Zheng, Yu; Wang, Kan; Zhang, Jingjing; Qin, Weijian; Yan, Xinyu; Shen, Guangxia; Gao, Guo; Pan, Fei; Cui, Daxiang

    2016-02-01

    Quantum dots-labeled urea-enzyme antibody-based rapid immunochromatographic test strips have been developed as quantitative fluorescence point-of-care tests (POCTs) to detect helicobacter pylori. Presented in this study is a new test strip reader designed to run on tablet personal computers (PCs), which is portable for outdoor detection even without an alternating current (AC) power supply. A Wi-Fi module was integrated into the reader to improve its portability. Patient information was loaded by a barcode scanner, and an application designed to run on tablet PCs was developed to handle the acquired images. A vision algorithm called Kmeans was used for picture processing. Different concentrations of various human blood samples were tested to evaluate the stability and accuracy of the fabricated device. Results demonstrate that the reader can provide an easy, rapid, simultaneous, quantitative detection for helicobacter pylori. The proposed test strip reader has a lighter weight than existing detection readers, and it can run for long durations without an AC power supply, thus verifying that it possesses advantages for outdoor detection. Given its fast detection speed and high accuracy, the proposed reader combined with quantum dots-labeled test strips is suitable for POCTs and owns great potential in applications such as screening patients with infection of helicobacter pylori, etc. in near future.

  13. [The quantitative recovery of microbes during testing of disinfectants for instruments].

    PubMed

    Höller, C; Gundermann, K O

    1990-02-01

    The efficacy of a disinfectant can only be determined exactly, when quantitative as well as qualitative tests are being performed. Aim of this study was to ascertain whether the earlier published method of a germ carrier test could be applied also to the testing of disinfectants for instruments. Rubber tubes of 1 cm length were used as germ carriers, Staph. aureus, Pseud. aerug., Proteus mir., E. coli and Cand. alb. as test organisms. The culture media were CASO-agar and -broth, latter containing 20% defibrinated sheep blood in some experiments. Two disinfectants on aldehyde-basis and one disinfectant on phenol-basis and on biguanide-basis, respectively, were used for the disinfectant tests. The rubber tubes were contaminated with bacterial suspension, dried upright on sterile filters and then put into 10 ml CASO-broth. After high speed vortexing of the germ carriers the bacterial count was determined. Following factors that were believed to probably having an influence on the recovery rate of bacteria were investigated: 1. the amount of fluid staying on the rubber tubes; 2. the drying time; 3. the vortexing time; 4. repeated vortexing; 5. variations of the initial concentration of bacteria on the rubber tubes; 6. addition of inactivating substances. ad 1. The mean amount of fluid staying on the tubes was 0.0056 g. ad 2. Drying times longer than 30 to 60 min resulted partly in considerably lower bacterial counts. ad. 3. and 4. Neither extension of vortexing time nor repeated vortexing of the same germ carrier could raise the recovery rate of bacteria. ad 5. Higher initial concentration of bacteria on the rubber tubes could not be achieved. The recovery rate of bacteria was reliable even when the initial bacterial concentration was low. ad 6. Addition of inactivating substances to the CASO-broth had no influence on the recovery rate of bacteria. The test method was checked by testing four disinfectants for instruments and proved itself a good and reliable

  14. Test of Achievement in Quantitative Economics for Secondary Schools: Construction and Validation Using Item Response Theory

    ERIC Educational Resources Information Center

    Eleje, Lydia I.; Esomonu, Nkechi P. M.

    2018-01-01

    A Test to measure achievement in quantitative economics among secondary school students was developed and validated in this study. The test is made up 20 multiple choice test items constructed based on quantitative economics sub-skills. Six research questions guided the study. Preliminary validation was done by two experienced teachers in…

  15. Comparison of quantitative and qualitative tests for glucose-6-phosphate dehydrogenase deficiency.

    PubMed

    LaRue, Nicole; Kahn, Maria; Murray, Marjorie; Leader, Brandon T; Bansil, Pooja; McGray, Sarah; Kalnoky, Michael; Zhang, Hao; Huang, Huiqiang; Jiang, Hui; Domingo, Gonzalo J

    2014-10-01

    A barrier to eliminating Plasmodium vivax malaria is inadequate treatment of infected patients. 8-Aminoquinoline-based drugs clear the parasite; however, people with glucose-6-phosphate dehydrogenase (G6PD) deficiency are at risk for hemolysis from these drugs. Understanding the performance of G6PD deficiency tests is critical for patient safety. Two quantitative assays and two qualitative tests were evaluated. The comparison of quantitative assays gave a Pearson correlation coefficient of 0.7585 with significant difference in mean G6PD activity, highlighting the need to adhere to a single reference assay. Both qualitative tests had high sensitivity and negative predictive value at a cutoff G6PD value of 40% of normal activity if interpreted conservatively and performed under laboratory conditions. The performance of both tests dropped at a cutoff level of 45%. Cytochemical staining of specimens confirmed that heterozygous females with > 50% G6PD-deficient cells can seem normal by phenotypic tests. © The American Society of Tropical Medicine and Hygiene.

  16. Initial CGE Model Results Summary Exogenous and Endogenous Variables Tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edwards, Brian Keith; Boero, Riccardo; Rivera, Michael Kelly

    The following discussion presents initial results of tests of the most recent version of the National Infrastructure Simulation and Analysis Center Dynamic Computable General Equilibrium (CGE) model developed by Los Alamos National Laboratory (LANL). The intent of this is to test and assess the model’s behavioral properties. The test evaluated whether the predicted impacts are reasonable from a qualitative perspective. This issue is whether the predicted change, be it an increase or decrease in other model variables, is consistent with prior economic intuition and expectations about the predicted change. One of the purposes of this effort is to determine whethermore » model changes are needed in order to improve its behavior qualitatively and quantitatively.« less

  17. A test for selection employing quantitative trait locus and mutation accumulation data.

    PubMed

    Rice, Daniel P; Townsend, Jeffrey P

    2012-04-01

    Evolutionary biologists attribute much of the phenotypic diversity observed in nature to the action of natural selection. However, for many phenotypic traits, especially quantitative phenotypic traits, it has been challenging to test for the historical action of selection. An important challenge for biologists studying quantitative traits, therefore, is to distinguish between traits that have evolved under the influence of strong selection and those that have evolved neutrally. Most existing tests for selection employ molecular data, but selection also leaves a mark on the genetic architecture underlying a trait. In particular, the distribution of quantitative trait locus (QTL) effect sizes and the distribution of mutational effects together provide information regarding the history of selection. Despite the increasing availability of QTL and mutation accumulation data, such data have not yet been effectively exploited for this purpose. We present a model of the evolution of QTL and employ it to formulate a test for historical selection. To provide a baseline for neutral evolution of the trait, we estimate the distribution of mutational effects from mutation accumulation experiments. We then apply a maximum-likelihood-based method of inference to estimate the range of selection strengths under which such a distribution of mutations could generate the observed QTL. Our test thus represents the first integration of population genetic theory and QTL data to measure the historical influence of selection.

  18. Distance-based microfluidic quantitative detection methods for point-of-care testing.

    PubMed

    Tian, Tian; Li, Jiuxing; Song, Yanling; Zhou, Leiji; Zhu, Zhi; Yang, Chaoyong James

    2016-04-07

    Equipment-free devices with quantitative readout are of great significance to point-of-care testing (POCT), which provides real-time readout to users and is especially important in low-resource settings. Among various equipment-free approaches, distance-based visual quantitative detection methods rely on reading the visual signal length for corresponding target concentrations, thus eliminating the need for sophisticated instruments. The distance-based methods are low-cost, user-friendly and can be integrated into portable analytical devices. Moreover, such methods enable quantitative detection of various targets by the naked eye. In this review, we first introduce the concept and history of distance-based visual quantitative detection methods. Then, we summarize the main methods for translation of molecular signals to distance-based readout and discuss different microfluidic platforms (glass, PDMS, paper and thread) in terms of applications in biomedical diagnostics, food safety monitoring, and environmental analysis. Finally, the potential and future perspectives are discussed.

  19. Neuropathic pain: is quantitative sensory testing helpful?

    PubMed

    Krumova, Elena K; Geber, Christian; Westermann, Andrea; Maier, Christoph

    2012-08-01

    Neuropathic pain arises as a consequence of a lesion or disease affecting the somatosensory system and is characterised by a combination of positive and negative sensory symptoms. Quantitative sensory testing (QST) examines the sensory perception after application of different mechanical and thermal stimuli of controlled intensity and the function of both large (A-beta) and small (A-delta and C) nerve fibres, including the corresponding central pathways. QST can be used to determine detection, pain thresholds and stimulus-response curves and can thus detect both negative and positive sensory signs, the second ones not being assessed by other methods. Similarly to all other psychophysical tests QST requires standardised examination, instructions and data evaluation to receive valid and reliable results. Since normative data are available, QST can contribute also to the individual diagnosis of neuropathy, especially in the case of isolated small-fibre neuropathy, in contrast to the conventional electrophysiology which assesses only large myelinated fibres. For example, detection of early stages of subclinical neuropathy in symptomatic or asymptomatic patients with diabetes mellitus can be helpful to optimise treatment and identify diabetic foot at risk of ulceration. QST assessed the individual's sensory profile and thus can be valuable to evaluate the underlying pain mechanisms which occur in different frequencies even in the same neuropathic pain syndromes. Furthermore, assessing the exact sensory phenotype by QST might be useful in the future to identify responders to certain treatments in accordance to the underlying pain mechanisms.

  20. Quantitative thermal sensory testing -- value of testing for both cold and warm sensation detection in evaluation of small fiber neuropathy.

    PubMed

    Shukla, Garima; Bhatia, Manvir; Behari, Madhuri

    2005-10-01

    Small fiber neuropathy is a common neurological disorder, often missed or ignored by physicians, since examination and routine nerve conduction studies are usually normal in this condition. Many methods including quantitative thermal sensory testing are currently being used for early detection of this condition, so as to enable timely investigation and treatment. This study was conducted to assess the yield of quantitative thermal sensory testing in diagnosis of small fiber neuropathy. We included patients presenting with history suggestive of positive and/or negative sensory symptoms, with normal examination findings, clinically suggestive of small fiber neuropathy, with normal or minimally abnormal routine nerve conduction studies. These patients were subjected to quantitative thermal sensory testing using a Medoc TSA-II Neurosensory analyser at two sites and for two modalities. QST data were compared with those in 120 normal healthy controls. Twenty-five patients (16 males, 9 females) with mean age 46.8+/-16.6 years (range: 21-75 years) were included in the study. The mean duration of symptoms was 1.6+/-1.6 years (range: 3 months-6 years). Eighteen patients (72%) had abnormal thresholds in at least one modality. Thermal thresholds were normal in 7 out of the 25 patients. This study demonstrates that quantitative thermal sensory testing is a fairly sensitive method for detection of small fiber neuropathy especially in patients with normal routine nerve conduction studies.

  1. Quantitative test for concave aspheric surfaces using a Babinet compensator.

    PubMed

    Saxena, A K

    1979-08-15

    A quantitative test for the evaluation of surface figures of concave aspheric surfaces using a Babinet compensator is reported. A theoretical estimate of the sensitivity is 0.002lambda for a minimum detectable phase change of 2 pi x 10(-3) rad over a segment length of 1.0 cm.

  2. Can quantitative sensory testing predict responses to analgesic treatment?

    PubMed

    Grosen, K; Fischer, I W D; Olesen, A E; Drewes, A M

    2013-10-01

    The role of quantitative sensory testing (QST) in prediction of analgesic effect in humans is scarcely investigated. This updated review assesses the effectiveness in predicting analgesic effects in healthy volunteers, surgical patients and patients with chronic pain. A systematic review of English written, peer-reviewed articles was conducted using PubMed and Embase (1980-2013). Additional studies were identified by chain searching. Search terms included 'quantitative sensory testing', 'sensory testing' and 'analgesics'. Studies on the relationship between QST and response to analgesic treatment in human adults were included. Appraisal of the methodological quality of the included studies was based on evaluative criteria for prognostic studies. Fourteen studies (including 720 individuals) met the inclusion criteria. Significant correlations were observed between responses to analgesics and several QST parameters including (1) heat pain threshold in experimental human pain, (2) electrical and heat pain thresholds, pressure pain tolerance and suprathreshold heat pain in surgical patients, and (3) electrical and heat pain threshold and conditioned pain modulation in patients with chronic pain. Heterogeneity among studies was observed especially with regard to application of QST and type and use of analgesics. Although promising, the current evidence is not sufficiently robust to recommend the use of any specific QST parameter in predicting analgesic response. Future studies should focus on a range of different experimental pain modalities rather than a single static pain stimulation paradigm. © 2013 European Federation of International Association for the Study of Pain Chapters.

  3. Comparison of 99mTc-MDP SPECT qualitative vs quantitative results in patients with suspected condylar hyperplasia.

    PubMed

    López Buitrago, D F; Ruiz Botero, J; Corral, C M; Carmona, A R; Sabogal, A

    To compare qualitative vs quantitative results of Single Photon Emission Computerised Tomography (SPECT), calculated from percentage of 99m Tc-MDP (methylene diphosphonate) uptake, in condyles of patients with a presumptive clinical diagnosis of condylar hyperplasia. A retrospective, descriptive study was conducted on the 99m Tc-MDP SPECT bone scintigraphy reports from 51 patients, with clinical impression of facial asymmetry related to condylar hyperplasia referred by their specialist in orthodontics or maxillofacial surgery, to a nuclear medicine department in order to take this type of test. Quantitative data from 99m Tc-MDP condylar uptake of each were obtained and compared with qualitative image interpretation reported by a nuclear medicine expert. The concordances between the 51 qualitative and quantitative reports results was established. The total sample included 32 women (63%) and 19 men (37%). The patient age range was 13-45 years (21±8 years). According to qualitative reports, 19 patients were positive for right side condylar hyperplasia, 12 for left side condylar hyperplasia, with 8 bilateral, and 12 negative. The quantitative reports diagnosed 16 positives for right side condylar hyperplasia, 10 for left side condylar hyperplasia, and 25 negatives. Nuclear medicine images are an important diagnostic tool, but the qualitative interpretation of the images is not as reliable as the quantitative calculation. The agreement between the two types of report is low (39.2%, Kappa=0.13; P>.2). The main limitation of quantitative reports is that they do not register bilateral condylar hyperplasia cases. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  4. Approaches to quantitating the results of differentially dyed cottons

    USDA-ARS?s Scientific Manuscript database

    The differential dyeing (DD) method has served as a subjective method for visually determining immature cotton fibers. In an attempt to quantitate the results of the differential dyeing method, and thus offer an efficient means of elucidating cotton maturity without visual discretion, image analysi...

  5. Real time blood testing using quantitative phase imaging.

    PubMed

    Pham, Hoa V; Bhaduri, Basanta; Tangella, Krishnarao; Best-Popescu, Catherine; Popescu, Gabriel

    2013-01-01

    We demonstrate a real-time blood testing system that can provide remote diagnosis with minimal human intervention in economically challenged areas. Our instrument combines novel advances in label-free optical imaging with parallel computing. Specifically, we use quantitative phase imaging for extracting red blood cell morphology with nanoscale sensitivity and NVIDIA's CUDA programming language to perform real time cellular-level analysis. While the blood smear is translated through focus, our system is able to segment and analyze all the cells in the one megapixel field of view, at a rate of 40 frames/s. The variety of diagnostic parameters measured from each cell (e.g., surface area, sphericity, and minimum cylindrical diameter) are currently not available with current state of the art clinical instruments. In addition, we show that our instrument correctly recovers the red blood cell volume distribution, as evidenced by the excellent agreement with the cell counter results obtained on normal patients and those with microcytic and macrocytic anemia. The final data outputted by our instrument represent arrays of numbers associated with these morphological parameters and not images. Thus, the memory necessary to store these data is of the order of kilobytes, which allows for their remote transmission via, for example, the cellular network. We envision that such a system will dramatically increase access for blood testing and furthermore, may pave the way to digital hematology.

  6. Pitch control margin at high angle of attack - Quantitative requirements (flight test correlation with simulation predictions)

    NASA Technical Reports Server (NTRS)

    Lackey, J.; Hadfield, C.

    1992-01-01

    Recent mishaps and incidents on Class IV aircraft have shown a need for establishing quantitative longitudinal high angle of attack (AOA) pitch control margin design guidelines for future aircraft. NASA Langley Research Center has conducted a series of simulation tests to define these design guidelines. Flight test results have confirmed the simulation studies in that pilot rating of high AOA nose-down recoveries were based on the short-term response interval in the forms of pitch acceleration and rate.

  7. Evaluation of a quantitative H2S MPN test for fecal microbes analysis of water using biochemical and molecular identification.

    PubMed

    McMahan, Lanakila; Grunden, Amy M; Devine, Anthony A; Sobsey, Mark D

    2012-04-15

    The sensitivity and specificity of the H(2)S test to detect fecal bacteria in water has been variable and uncertain in previous studies, partly due to its presence-absence results. Furthermore, in groundwater samples false-positive results have been reported, with H(2)S-positive samples containing no fecal coliforms or Escherichia coli. False-negative results also have been reported in other studies, with H(2)S-negative samples found to contain E. coli. Using biochemical and molecular methods and a novel quantitative test format, this research identified the types and numbers of microbial community members present in natural water samples, including fecal indicators and pathogens as well as other bacteria. Representative water sources tested in this study included cistern rainwater, a protected lake, and wells in agricultural and forest settings. Samples from quantitative H(2)S tests of water were further cultured for fecal bacteria by spread plating onto the selective media for detection and isolation of Aeromonas spp., E. coli, Clostridium spp., H(2)S-producers, and species of Salmonella and Shigella. Isolates were then tested for H(2)S production, and identified to the genus and species level using biochemical methods. Terminal Restriction Fragment Length Polymorphisms (TRFLP) was the molecular method employed to quantitatively characterize microbial community diversity. Overall, it was shown that water samples testing positive for H(2)S bacteria also had bacteria of likely fecal origin and waters containing fecal pathogens also were positive for H(2)S bacteria. Of the microorganisms isolated from natural water, greater than 70 percent were identified using TRFLP analysis to reveal a relatively stable group of organisms whose community composition differed with water source and over time. These results further document the validity of the H(2)S test for detecting and quantifying fecal contamination of water. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Quantitative Sensory Testing Predicts Pregabalin Efficacy in Painful Chronic Pancreatitis

    PubMed Central

    Olesen, Søren S.; Graversen, Carina; Bouwense, Stefan A. W.; van Goor, Harry; Wilder-Smith, Oliver H. G.; Drewes, Asbjørn M.

    2013-01-01

    Background A major problem in pain medicine is the lack of knowledge about which treatment suits a specific patient. We tested the ability of quantitative sensory testing to predict the analgesic effect of pregabalin and placebo in patients with chronic pancreatitis. Methods Sixty-four patients with painful chronic pancreatitis received pregabalin (150–300 mg BID) or matching placebo for three consecutive weeks. Analgesic effect was documented in a pain diary based on a visual analogue scale. Responders were defined as patients with a reduction in clinical pain score of 30% or more after three weeks of study treatment compared to baseline recordings. Prior to study medication, pain thresholds to electric skin and pressure stimulation were measured in dermatomes T10 (pancreatic area) and C5 (control area). To eliminate inter-subject differences in absolute pain thresholds an index of sensitivity between stimulation areas was determined (ratio of pain detection thresholds in pancreatic versus control area, ePDT ratio). Pain modulation was recorded by a conditioned pain modulation paradigm. A support vector machine was used to screen sensory parameters for their predictive power of pregabalin efficacy. Results The pregabalin responders group was hypersensitive to electric tetanic stimulation of the pancreatic area (ePDT ratio 1.2 (0.9–1.3)) compared to non-responders group (ePDT ratio: 1.6 (1.5–2.0)) (P = 0.001). The electrical pain detection ratio was predictive for pregabalin effect with a classification accuracy of 83.9% (P = 0.007). The corresponding sensitivity was 87.5% and specificity was 80.0%. No other parameters were predictive of pregabalin or placebo efficacy. Conclusions The present study provides first evidence that quantitative sensory testing predicts the analgesic effect of pregabalin in patients with painful chronic pancreatitis. The method can be used to tailor pain medication based on patient’s individual sensory profile and thus

  9. A quantitative test of population genetics using spatiogenetic patterns in bacterial colonies.

    PubMed

    Korolev, Kirill S; Xavier, João B; Nelson, David R; Foster, Kevin R

    2011-10-01

    It is widely accepted that population-genetics theory is the cornerstone of evolutionary analyses. Empirical tests of the theory, however, are challenging because of the complex relationships between space, dispersal, and evolution. Critically, we lack quantitative validation of the spatial models of population genetics. Here we combine analytics, on- and off-lattice simulations, and experiments with bacteria to perform quantitative tests of the theory. We study two bacterial species, the gut microbe Escherichia coli and the opportunistic pathogen Pseudomonas aeruginosa, and show that spatiogenetic patterns in colony biofilms of both species are accurately described by an extension of the one-dimensional stepping-stone model. We use one empirical measure, genetic diversity at the colony periphery, to parameterize our models and show that we can then accurately predict another key variable: the degree of short-range cell migration along an edge. Moreover, the model allows us to estimate other key parameters, including effective population size (density) at the expansion frontier. While our experimental system is a simplification of natural microbial community, we argue that it constitutes proof of principle that the spatial models of population genetics can quantitatively capture organismal evolution.

  10. Impaired limb position sense after stroke: a quantitative test for clinical use.

    PubMed

    Carey, L M; Oke, L E; Matyas, T A

    1996-12-01

    A quantitative measure of wrist position sense was developed to advance clinical measurement of proprioceptive limb sensibility after stroke. Test-retest reliability, normative standards, and ability to discriminate impaired and unimpaired performance were investigated. Retest reliability was assessed over three sessions, and a matched-pairs study compared stroke and unimpaired subjects. Both wrists were tested, in counterbalanced order. Patients were tested in hospital-based rehabilitation units. Reliability was investigated on a consecutive sample of 35 adult stroke patients with a range of proprioceptive discrimination abilities and no evidence of neglect. A consecutive sample of 50 stroke patients and convenience sample of 50 healthy volunteers, matched for age, sex, and hand dominance, were tested in the normative-discriminative study. Age and sex were representative of the adult stroke population. The test required matching of imposed wrist positions using a pointer aligned with the axis of movement and a protractor scale. The test was reliable (r = .88 and .92) and observed changes of 8 degrees can be interpreted, with 95% confidence, as genuine. Scores of healthy volunteers ranged from 3.1 degrees to 10.9 degrees average error. The criterion of impairment was conservatively defined as 11 degrees (+/-4.8 degrees) average error. Impaired and unimpaired performance were well differentiated. Clinicians can confidently and quantitatively sample one aspect of proprioceptive sensibility in stroke patients using the wrist position sense test. Development of tests on other joints using the present approach is supported by our findings.

  11. The quantitative LOD score: test statistic and sample size for exclusion and linkage of quantitative traits in human sibships.

    PubMed

    Page, G P; Amos, C I; Boerwinkle, E

    1998-04-01

    We present a test statistic, the quantitative LOD (QLOD) score, for the testing of both linkage and exclusion of quantitative-trait loci in randomly selected human sibships. As with the traditional LOD score, the boundary values of 3, for linkage, and -2, for exclusion, can be used for the QLOD score. We investigated the sample sizes required for inferring exclusion and linkage, for various combinations of linked genetic variance, total heritability, recombination distance, and sibship size, using fixed-size sampling. The sample sizes required for both linkage and exclusion were not qualitatively different and depended on the percentage of variance being linked or excluded and on the total genetic variance. Information regarding linkage and exclusion in sibships larger than size 2 increased as approximately all possible pairs n(n-1)/2 up to sibships of size 6. Increasing the recombination (theta) distance between the marker and the trait loci reduced empirically the power for both linkage and exclusion, as a function of approximately (1-2theta)4.

  12. QUANTITATIVE TESTS OF ELMS AS INTERMEDIATE N PEELING-BALOONING MODES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LAO,LL; SNYDER,PB; LEONARD,AW

    2003-03-01

    A271 QUANTITATIVE TESTS OF ELMS AS INTERMEDIATE N PEELING-BALOONING MODES. Several testable features of the working model of edge localized modes (ELMs) as intermediate toroidal mode number peeling-ballooning modes are evaluated quantitatively using DIII-D and JT-60U experimental data and the ELITE MHD stability code. These include the hypothesis that ELM sizes are related to the radial widths of the unstable MHD modes, the unstable modes have a strong ballooning character localized in the outboard bad curvature region, and ELM size generally becomes smaller at high edge collisionality. ELMs are triggered when the growth rates of the unstable MHD modes becomemore » significantly large. These testable features are consistent with many ELM observations in DIII-D and JT-60U discharges.« less

  13. Incorporating uncertainty into medical decision making: an approach to unexpected test results.

    PubMed

    Bianchi, Matt T; Alexander, Brian M; Cash, Sydney S

    2009-01-01

    The utility of diagnostic tests derives from the ability to translate the population concepts of sensitivity and specificity into information that will be useful for the individual patient: the predictive value of the result. As the array of available diagnostic testing broadens, there is a temptation to de-emphasize history and physical findings and defer to the objective rigor of technology. However, diagnostic test interpretation is not always straightforward. One significant barrier to routine use of probability-based test interpretation is the uncertainty inherent in pretest probability estimation, the critical first step of Bayesian reasoning. The context in which this uncertainty presents the greatest challenge is when test results oppose clinical judgment. It is this situation when decision support would be most helpful. The authors propose a simple graphical approach that incorporates uncertainty in pretest probability and has specific application to the interpretation of unexpected results. This method quantitatively demonstrates how uncertainty in disease probability may be amplified when test results are unexpected (opposing clinical judgment), even for tests with high sensitivity and specificity. The authors provide a simple nomogram for determining whether an unexpected test result suggests that one should "switch diagnostic sides.'' This graphical framework overcomes the limitation of pretest probability uncertainty in Bayesian analysis and guides decision making when it is most challenging: interpretation of unexpected test results.

  14. Stability Test and Quantitative and Qualitative Analyses of the Amino Acids in Pharmacopuncture Extracted from Scolopendra subspinipes mutilans

    PubMed Central

    Cho, GyeYoon; Han, KyuChul; Yoon, JinYoung

    2015-01-01

    Objectives: Scolopendra subspinipes mutilans (S. subspinipes mutilans) is known as a traditional medicine and includes various amino acids, peptides and proteins. The amino acids in the pharmacopuncture extracted from S. subspinipes mutilans by using derivatization methods were analyzed quantitatively and qualitatively by using high performance liquid chromatography (HPLC) over a 12 month period to confirm its stability. Methods: Amino acids of pharmacopuncture extracted from S. subspinipes mutilans were derived by using O-phthaldialdehyde (OPA) & 9-fluorenyl methoxy carbonyl chloride (FMOC) reagent and were analyzed using HPLC. The amino acids were detected by using a diode array detector (DAD) and a fluorescence detector (FLD) to compare a mixed amino acid standard (STD) to the pharmacopuncture from centipedes. The stability tests on the pharmacopuncture from centipedes were done using HPLC for three conditions: a room temperature test chamber, an acceleration test chamber, and a cold test chamber. Results: The pharmacopuncture from centipedes was prepared by using the method of the Korean Pharmacopuncture Institute (KPI) and through quantitative analyses was shown to contain 9 amino acids of the 16 amino acids in the mixed amino acid STD. The amounts of the amino acids in the pharmacopuncture from centipedes were 34.37 ppm of aspartate, 123.72 ppm of arginine, 170.63 ppm of alanine, 59.55 ppm of leucine and 57 ppm of lysine. The relative standard deviation (RSD %) results for the pharmacopuncture from centipedes had a maximum value of 14.95% and minimum value of 1.795% on the room temperature test chamber, the acceleration test chamber and the cold test chamber stability tests. Conclusion: Stability tests on and quantitative and qualitative analyses of the amino acids in the pharmacopuncture extracted from centipedes by using derivatization methods were performed by using HPLC. Through research, we hope to determine the relationship between time and the

  15. Quantitative comparison of the pivot shift test results before and after anterior cruciate ligament reconstruction by using the three-dimensional electromagnetic measurement system.

    PubMed

    Nagai, Kanto; Hoshino, Yuichi; Nishizawa, Yuichiro; Araki, Daisuke; Matsushita, Takehiko; Matsumoto, Tomoyuki; Takayama, Koji; Nagamune, Kouki; Kurosaka, Masahiro; Kuroda, Ryosuke

    2015-10-01

    Tibial acceleration during the pivot shift test is a potential quantitative parameter to evaluate rotational laxity of anterior cruciate ligament (ACL) insufficiency. However, clinical application of this measurement has not been fully examined. This study aimed to measure and compare tibial acceleration before and after ACL reconstruction (ACLR) in ACL-injured patients. We hypothesized tibial acceleration would be reduced by ACLR and tibial acceleration would be consistent in the same knee at different time points. Seventy ACL-injured patients who underwent ACLR were enrolled. Tibial acceleration during the pivot shift test was measured using an electromagnetic measurement system before ALCR and at the second-look arthroscopy 1 year post-operatively. Tibial acceleration was compared to clinical grading and between ACL-injured/ACL-reconstructed and contralateral knees. Pre-operative tibial acceleration was increased stepwise with the increase in clinical grading (P < 0.01). Tibial acceleration in ACL-injured knee (1.9 ± 1.2 m/s(2)) was larger than that in the contralateral knee (0.8 ± 0.3 m/s(2), P < 0.01), and reduced to 0.9 ± 0.3 m/s(2) post-operatively (P < 0.01). There was no difference between ACL-reconstructed and contralateral knee (n.s.). Tibial acceleration in contralateral knees was consistent pre- and post-operatively (n.s.). Tibial acceleration measurement demonstrated increased rotational laxity in ACL-injured knees and its reduction by ALCR. Additionally, consistent measurements were obtained in ACL-intact knees at different time points. Therefore, tibial acceleration during the pivot shift test could provide quantitative evaluation of rotational stability before and after ACL reconstruction. III.

  16. Quantitative fetal fibronectin and cervical length in symptomatic women: results from a prospective blinded cohort study.

    PubMed

    Levine, Lisa D; Downes, Katheryne L; Romero, Julie A; Pappas, Hope; Elovitz, Michal A

    2018-05-15

    Our objectives were to determine whether quantitative fetal fibronectin (fFN) and cervical length (CL) screening can be used alone or in combination as prognostic tests to identify symptomatic women at the highest or lowest risk for spontaneous preterm birth (sPTB). A prospective, blinded cohort study of women presenting with a singleton gestation to our triage unit between 22-33w6d with preterm labor symptoms was performed. Women with ruptured membranes, moderate/severe bleeding, and dilation >2 cm were excluded. The primary outcome was sPTB <37 weeks. We evaluated test characteristics of quantitative fFN and CL assessment, both separately and in combination, considering traditionally reported cut-points (fFN ≥50 and CL <25), as well as cut-points above and below these measures. We found interactions between fFN >50 and CL <25 and sPTB by parity and obstetric history (p < .05) and therefore stratified results. Test characteristics are presented with positive predictive value (PPV) and negative predictive value (NPV). Five hundred eighty women were enrolled and 537 women were available for analysis. Overall sPTB rate was 11.1%. Among nulliparous women, increasing levels of fFN were associated with increasing risk of sPTB, with PPV going from 26.5% at ≥20 ng/mL to 44.4% at ≥200 ng/mL. A cut-point of 20 ng/mL had higher sensitivity (69.2%) and higher NPV (96.8%) and therefore identified a "low-risk" group. fFN was not informative for multiparous women regardless of prior obstetrical history or quantitative level chosen. For all women, a shorter CL was associated with an increased sPTB risk. Among nulliparas and multiparas without a prior sPTB, a CL <20 mm optimized test characteristics (PPV 25 and 20%, NPV 95.5, and 92.7%, respectively). For multiparas with a prior sPTB, CL <25 mm was more useful. Using fFN and CL in combination for nulliparas did not improve test characteristics over using the individual fFN (p = .74) and CL (p = .31

  17. Sweat conductivity and coulometric quantitative test in neonatal cystic fibrosis screening.

    PubMed

    Domingos, Mouseline Torquato; Magdalena, Neiva Isabel Rodrigues; Cat, Mônica Nunes Lima; Watanabe, Alexandra Mitiru; Rosário Filho, Nelson Augusto

    2015-01-01

    To compare the results obtained with the sweat test using the conductivity method and coulometric measurement of sweat chloride in newborns (NBs) with suspected cystic fibrosis (CF) in the neonatal screening program. The sweat test was performed simultaneously by both methods in children with and without CF. The cutoff values to confirm CF were >50 mmol/L in the conductivity and >60 mmol/L in the coulometric test. There were 444 infants without CF (185 males, 234 females, and 24 unreported) submitted to the sweat test through conductivity and coulometric measurement simultaneously, obtaining median results of 32 mmol/L and 12 mmol/L, respectively. For 90 infants with CF, the median values of conductivity and coulometric measurement were 108 mmol/L and 97 mmol/L, respectively. The false positive rate for conductivity was 16.7%, and was higher than 50 mmol/L in all patients with CF, which gives this method a sensitivity of 100% (95% CI: 93.8-97.8), specificity of 96.2% (95% CI: 93.8-97.8), positive predictive value of 83.3% (95% CI: 74.4-91.1), negative predictive value of 100% (95% CI: 90.5-109.4), and 9.8% accuracy. The correlation between the methods was r=0.97 (p>0.001). The best suggested cutoff value was 69.0 mmol/L, with a kappa coefficient=0.89. The conductivity test showed excellent correlation with the quantitative coulometric test, high sensitivity and specificity, and can be used in the diagnosis of CF in children detected through newborn screening. Copyright © 2015 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  18. The Quantitative-MFG Test: A Linear Mixed Effect Model to Detect Maternal-Offspring Gene Interactions.

    PubMed

    Clark, Michelle M; Blangero, John; Dyer, Thomas D; Sobel, Eric M; Sinsheimer, Janet S

    2016-01-01

    Maternal-offspring gene interactions, aka maternal-fetal genotype (MFG) incompatibilities, are neglected in complex diseases and quantitative trait studies. They are implicated in birth to adult onset diseases but there are limited ways to investigate their influence on quantitative traits. We present the quantitative-MFG (QMFG) test, a linear mixed model where maternal and offspring genotypes are fixed effects and residual correlations between family members are random effects. The QMFG handles families of any size, common or general scenarios of MFG incompatibility, and additional covariates. We develop likelihood ratio tests (LRTs) and rapid score tests and show they provide correct inference. In addition, the LRT's alternative model provides unbiased parameter estimates. We show that testing the association of SNPs by fitting a standard model, which only considers the offspring genotypes, has very low power or can lead to incorrect conclusions. We also show that offspring genetic effects are missed if the MFG modeling assumptions are too restrictive. With genome-wide association study data from the San Antonio Family Heart Study, we demonstrate that the QMFG score test is an effective and rapid screening tool. The QMFG test therefore has important potential to identify pathways of complex diseases for which the genetic etiology remains to be discovered. © 2015 John Wiley & Sons Ltd/University College London.

  19. Quantitative nephelometry

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/003545.htm Quantitative nephelometry test To use the sharing features on this page, please enable JavaScript. Quantitative nephelometry is a lab test to quickly and ...

  20. Quantitative Improvements in Hop Test Scores After a 6-Week Neuromuscular Training Program

    PubMed Central

    Meierbachtol, Adam; Rohman, Eric; Paur, Eric; Bottoms, John; Tompkins, Marc

    2016-01-01

    Background: In patients who have undergone anterior cruciate ligament reconstruction (ACLR), the effect of neuromuscular re-education (NMR) programs on standard hop tests outcomes, including limb symmetry indices (LSIs), is unknown. Hypothesis: Both legs will show improvement in hop test–measured units after neuromuscular training, but the involved leg will show relatively greater improvement leading to improved limb symmetry. Patients younger than 18 years will show more improvement than patients who are older. Study Design: Retrospective cohort study. Level of Evidence: Level 3. Methods: Patients self-selected their participation in this NMR program, which was completed after traditional outpatient physical therapy. Pre– and post–hop test scores were recorded as the primary outcome measure. Results: Seventy-one patients met the inclusion criteria and completed hop testing. Overall, the involved leg showed significant improvements (pretest/posttest) for single-leg hop (138.30 cm/156.89 cm), triple crossover hop (370.05 cm/423.11 cm), and timed hop (2.21 s/1.99 s). Similarly, on the uninvolved leg, improvements were seen for the single-leg hop (159.30 cm/171.87 cm) and triple crossover hop (427.50 cm/471.27 cm). Overall mean limb symmetry improved across all 4 hop tests, but there was significant improvement only on the single-leg hop (87% pretest to 92% posttest). Patients younger than 18 years showed mean significant LSI improvement on the triple crossover hop. Conclusion: Utilizing an intensive 6-week NMR program after ACLR prior to return to sport can improve quantitative hop test measurements. Patients younger than 18 years had greater improvement than those 18 years and older. Clinical Relevance: Advanced NMR programs can be successfully utilized in the postoperative ACLR setting to improve quantitative limb symmetry. PMID:27620968

  1. A quantitative evaluation of spurious results in the infrared spectroscopic measurement of CO2 isotope ratios

    NASA Astrophysics Data System (ADS)

    Mansfield, C. D.; Rutt, H. N.

    2002-02-01

    The possible generation of spurious results, arising from the application of infrared spectroscopic techniques to the measurement of carbon isotope ratios in breath, due to coincident absorption bands has been re-examined. An earlier investigation, which approached the problem qualitatively, fulfilled its aspirations in providing an unambiguous assurance that 13C16O2/12C16O2 ratios can be confidently measured for isotopic breath tests using instruments based on infrared absorption. Although this conclusion still stands, subsequent quantitative investigation has revealed an important exception that necessitates a strict adherence to sample collection protocol. The results show that concentrations and decay rates of the coincident breath trace compounds acetonitrile and carbon monoxide, found in the breath sample of a heavy smoker, can produce spurious results. Hence, findings from this investigation justify the concern that breath trace compounds present a risk to the accurate measurement of carbon isotope ratios in breath when using broadband, non-dispersive, ground state absorption infrared spectroscopy. It provides recommendations on the length of smoking abstention required to avoid generation of spurious results and also reaffirms, through quantitative argument, the validity of using infrared absorption spectroscopy to measure CO2 isotope ratios in breath.

  2. Qualification Testing Versus Quantitative Reliability Testing of PV - Gaining Confidence in a Rapidly Changing Technology: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurtz, Sarah; Repins, Ingrid L; Hacke, Peter L

    Continued growth of PV system deployment would be enhanced by quantitative, low-uncertainty predictions of the degradation and failure rates of PV modules and systems. The intended product lifetime (decades) far exceeds the product development cycle (months), limiting our ability to reduce the uncertainty of the predictions for this rapidly changing technology. Yet, business decisions (setting insurance rates, analyzing return on investment, etc.) require quantitative risk assessment. Moving toward more quantitative assessments requires consideration of many factors, including the intended application, consequence of a possible failure, variability in the manufacturing, installation, and operation, as well as uncertainty in the measured accelerationmore » factors, which provide the basis for predictions based on accelerated tests. As the industry matures, it is useful to periodically assess the overall strategy for standards development and prioritization of research to provide a technical basis both for the standards and the analysis related to the application of those. To this end, this paper suggests a tiered approach to creating risk assessments. Recent and planned potential improvements in international standards are also summarized.« less

  3. Quantitative Sensory Testing and Current Perception Threshold Testing in Patients With Chronic Pain Following Lower Extremity Fracture.

    PubMed

    Griffioen, Mari A; Greenspan, Joel D; Johantgen, Meg; Von Rueden, Kathryn; O'Toole, Robert V; Dorsey, Susan G; Renn, Cynthia L

    2018-01-01

    Chronic pain is a significant problem for patients with lower extremity injuries. While pain hypersensitivity has been identified in many chronic pain conditions, it is not known whether patients with chronic pain following lower extremity fracture report pain hypersensitivity in the injured leg. To quantify and compare peripheral somatosensory function and sensory nerve activation thresholds in persons with chronic pain following lower extremity fractures with a cohort of persons with no history of lower extremity fractures. This was a cross-sectional study where quantitative sensory testing and current perception threshold testing were conducted on the injured and noninjured legs of cases and both legs of controls. A total of 14 cases and 28 controls participated in the study. Mean time since injury at the time of testing for cases was 22.3 (standard deviation = 12.1) months. The warmth detection threshold ( p = .024) and nerve activation thresholds at 2,000 Hz ( p < .001) and 250 Hz ( p = .002), respectively, were significantly higher in cases compared to controls. This study suggests that patients with chronic pain following lower extremity fractures may experience hypoesthesia in the injured leg, which contrasts with the finding of hyperesthesia previously observed in other chronic pain conditions but is in accord with patients with nerve injuries and surgeries. This is the first study to examine peripheral sensory nerve function at the site of injury in patients with chronic pain following lower extremity fractures using quantitative sensory testing and current perception threshold testing.

  4. Quantitative Assessment of Commutability for Clinical Viral Load Testing Using a Digital PCR-Based Reference Standard

    PubMed Central

    Tang, L.; Sun, Y.; Buelow, D.; Gu, Z.; Caliendo, A. M.; Pounds, S.

    2016-01-01

    Given recent advances in the development of quantitative standards, particularly WHO international standards, efforts to better understand the commutability of reference materials have been made. Existing approaches in evaluating commutability include prediction intervals and correspondence analysis; however, the results obtained from existing approaches may be ambiguous. We have developed a “deviation-from-ideal” (DFI) approach to evaluate commutability of standards and applied it to the assessment of Epstein-Bar virus (EBV) load testing in four quantitative PCR assays, treating digital PCR as a reference assay. We then discuss advantages and limitations of the DFI approach as well as experimental design to best evaluate the commutability of an assay in practice. PMID:27076654

  5. Susceptibility Testing by Polymerase Chain Reaction DNA Quantitation: A Method to Measure Drug Resistance of Human Immunodeficiency Virus Type 1 Isolates

    NASA Astrophysics Data System (ADS)

    Eron, Joseph J.; Gorczyca, Paul; Kaplan, Joan C.; D'Aquila, Richard T.

    1992-04-01

    Polymerase chain reaction (PCR) DNA quantitation (PDQ) susceptibility testing rapidly and directly measures nucleoside sensitivity of human immunodeficiency virus type 1 (HIV-1) isolates. PCR is used to quantitate the amount of HIV-1 DNA synthesized after in vitro infection of peripheral blood mononuclear cells. The relative amounts of HIV-1 DNA in cell lysates from cultures maintained at different drug concentrations reflect drug inhibition of virus replication. The results of PDQ susceptibility testing of 2- or 3-day cultures are supported by assays measuring HIV-1 p24 antigen production in supernatants of 7- or 10-day cultures. DNA sequence analyses to identify mutations in the reverse transcriptase gene that cause resistance to 3'-azido-3'-deoxythymidine also support the PDQ results. With the PDQ method, both infectivity titration and susceptibility testing can be performed on supernatants from primary cultures of peripheral blood mononuclear cells. PDQ susceptibility testing should facilitate epidemiologic studies of the clinical significance of drug-resistant HIV-1 isolates.

  6. Stability Test and Quantitative and Qualitative Analyses of the Amino Acids in Pharmacopuncture Extracted from Scolopendra subspinipes mutilans.

    PubMed

    Cho, GyeYoon; Han, KyuChul; Yoon, JinYoung

    2015-03-01

    Scolopendra subspinipes mutilans (S. subspinipes mutilans) is known as a traditional medicine and includes various amino acids, peptides and proteins. The amino acids in the pharmacopuncture extracted from S. subspinipes mutilans by using derivatization methods were analyzed quantitatively and qualitatively by using high performance liquid chromatography (HPLC) over a 12 month period to confirm its stability. Amino acids of pharmacopuncture extracted from S. subspinipes mutilans were derived by using O-phthaldialdehyde (OPA) & 9-fluorenyl methoxy carbonyl chloride (FMOC) reagent and were analyzed using HPLC. The amino acids were detected by using a diode array detector (DAD) and a fluorescence detector (FLD) to compare a mixed amino acid standard (STD) to the pharmacopuncture from centipedes. The stability tests on the pharmacopuncture from centipedes were done using HPLC for three conditions: a room temperature test chamber, an acceleration test chamber, and a cold test chamber. The pharmacopuncture from centipedes was prepared by using the method of the Korean Pharmacopuncture Institute (KPI) and through quantitative analyses was shown to contain 9 amino acids of the 16 amino acids in the mixed amino acid STD. The amounts of the amino acids in the pharmacopuncture from centipedes were 34.37 ppm of aspartate, 123.72 ppm of arginine, 170.63 ppm of alanine, 59.55 ppm of leucine and 57 ppm of lysine. The relative standard deviation (RSD %) results for the pharmacopuncture from centipedes had a maximum value of 14.95% and minimum value of 1.795% on the room temperature test chamber, the acceleration test chamber and the cold test chamber stability tests. Stability tests on and quantitative and qualitative analyses of the amino acids in the pharmacopuncture extracted from centipedes by using derivatization methods were performed by using HPLC. Through research, we hope to determine the relationship between time and the concentrations of the amino acids in the

  7. Relationship between self-reported upper limb disability and quantitative tests in hand-arm vibration syndrome.

    PubMed

    Poole, Kerry; Mason, Howard

    2007-03-15

    To establish the relationship between quantitative tests of hand function and upper limb disability, as measured by the Disability of the Arm, Shoulder and Hand (DASH) questionnaire, in hand-arm vibration syndrome (HAVS). A total of 228 individuals with HAVS were included in this study. Each had undergone a full HAVS assessment by an experienced physician, including quantitative tests of vibrotactile and thermal perception thresholds, maximal hand-grip strength (HG) and the Purdue pegboard (PP) test. Individuals were also asked to complete a DASH questionnaire. PP and HG of the quantitative tests gave the best and statistically significant individual correlations with the DASH disability score (r2 = 0.168 and 0.096). Stepwise linear regression analysis revealed that only PP and HG measurements were statistically significant predictors of upper limb disability (r2 = 0.178). Overall a combination of the PP and HG measurements, rather than each alone, gave slightly better discrimination, although not statistically significant, between normal and abnormal DASH scores with a sensitivity of 73.1% and specificity of 64.3%. Measurements of manual dexterity and hand-grip strength using PP and HG may be useful in helping to confirm lack of upper limb function and 'perceived' disability in HAVS.

  8. 10 CFR 26.169 - Reporting Results.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... request. The laboratory shall routinely provide quantitative values for confirmatory opiate test results... requested quantitative values for the test result. (3) For a specimen that has an adulterated or substituted... of the standard curve, the laboratory may report to the MRO that the quantitative value “exceeds the...

  9. 10 CFR 26.169 - Reporting Results.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... request. The laboratory shall routinely provide quantitative values for confirmatory opiate test results... requested quantitative values for the test result. (3) For a specimen that has an adulterated or substituted... of the standard curve, the laboratory may report to the MRO that the quantitative value “exceeds the...

  10. 10 CFR 26.169 - Reporting Results.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... request. The laboratory shall routinely provide quantitative values for confirmatory opiate test results... requested quantitative values for the test result. (3) For a specimen that has an adulterated or substituted... of the standard curve, the laboratory may report to the MRO that the quantitative value “exceeds the...

  11. 10 CFR 26.169 - Reporting Results.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... request. The laboratory shall routinely provide quantitative values for confirmatory opiate test results... requested quantitative values for the test result. (3) For a specimen that has an adulterated or substituted... of the standard curve, the laboratory may report to the MRO that the quantitative value “exceeds the...

  12. 10 CFR 26.169 - Reporting Results.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... request. The laboratory shall routinely provide quantitative values for confirmatory opiate test results... requested quantitative values for the test result. (3) For a specimen that has an adulterated or substituted... of the standard curve, the laboratory may report to the MRO that the quantitative value “exceeds the...

  13. Idiopathic normal pressure hydrocephalus, quantitative EEG findings, and the cerebrospinal fluid tap test: a pilot study.

    PubMed

    Seo, Jong-Geun; Kang, Kyunghun; Jung, Ji-Young; Park, Sung-Pa; Lee, Maan-Gee; Lee, Ho-Won

    2014-12-01

    In this pilot study, we analyzed relationships between quantitative EEG measurements and clinical parameters in idiopathic normal pressure hydrocephalus patients, along with differences in these quantitative EEG markers between cerebrospinal fluid tap test responders and nonresponders. Twenty-six idiopathic normal pressure hydrocephalus patients (9 cerebrospinal fluid tap test responders and 17 cerebrospinal fluid tap test nonresponders) constituted the final group for analysis. The resting EEG was recorded and relative powers were computed for seven frequency bands. Cerebrospinal fluid tap test nonresponders, when compared with responders, showed a statistically significant increase in alpha2 band power at the right frontal and centrotemporal regions. Higher delta2 band powers in the frontal, central, parietal, and occipital regions and lower alpha1 band powers in the right temporal region significantly correlated with poorer cognitive performance. Higher theta1 band powers in the left parietal and occipital regions significantly correlated with gait dysfunction. And higher delta1 band powers in the right frontal regions significantly correlated with urinary disturbance. Our findings may encourage further research using quantitative EEG in patients with ventriculomegaly as a potential electrophysiological marker for predicting cerebrospinal fluid tap test responders. This study additionally suggests that the delta, theta, and alpha bands are statistically correlated with the severity of symptoms in idiopathic normal pressure hydrocephalus patients.

  14. [The quantitative testing of V617F mutation in gen JAK2 using pyrosequencing technique].

    PubMed

    Dunaeva, E A; Mironov, K O; Dribnokhodova, T E; Subbotina, E E; Bashmakova; Ol'hovskiĭ, I A; Shipulin, G A

    2014-11-01

    The somatic mutation V617F in gen JAK2 is a frequent cause of chronic myeloprolific diseases not conditioned by BCR/ABL mutation. The quantitative testing of relative percentage of mutant allele can be used in establishing severity of disease and its prognosis and in prescription of remedy inhibiting activity of JAK2. To quantitatively test mutation the pyrosequencing technique was applied. The developed technique permits detecting and quantitatively, testing percentage of mutation fraction since 7%. The "gray zone" is presented by samples with percentage of mutant allele from 4% to 7%. The dependence of expected percentage of mutant fraction in analyzed sample from observed value of signal is described by equation of line with regression coefficients y = - 0.97, x = -1.32 and at that measurement uncertainty consists ± 0.7. The developed technique is approved officially on clinical material from 192 patients with main forms of myeloprolific diseases not conditioned by BCR/ABL mutation. It was detected 64 samples with mautant fraction percentage from 13% to 91%. The developed technique permits implementing monitoring of therapy of myeloprolific diseases and facilitates to optimize tactics of treatment.

  15. Evaluation of a rapid quantitative determination method of PSA concentration with gold immunochromatographic strips.

    PubMed

    Wu, Cheng-Ching; Lin, Hung-Yu; Wang, Chao-Ping; Lu, Li-Fen; Yu, Teng-Hung; Hung, Wei-Chin; Houng, Jer-Yiing; Chung, Fu-Mei; Lee, Yau-Jiunn; Hu, Jin-Jia

    2015-11-03

    Prostate cancer remains the most common cancer in men. Qualitative or semi-quantitative immunochromatographic measurements of prostate specific antigen (PSA) have been shown to be simple, noninvasive and feasible. The aim of this study was to evaluate an optimized gold immunochromatographic strip device for the detection of PSA, in which the results can be analysed using a Chromogenic Rapid Test Reader to quantitatively assess the test results. This reader measures the reflectance of the signal line via a charge-coupled device camera. For quantitative analysis, PSA concentration was computed via a calibration equation. Capillary blood samples from 305 men were evaluated, and two independent observers interpreted the test results after 12 min. Blood samples were also collected and tested with a conventional quantitative assay. Sensitivity, specificity, positive and negative predictive values, and accuracy of the PSA rapid quantitative test system were 100, 96.6, 89.5, 100, and 97.4 %, respectively. Reproducibility of the test was 99.2, and interobserver variation was 8 % with a false positive rate of 3.4 %. The correlation coefficient between the ordinary quantitative assay and the rapid quantitative test was 0.960. The PSA rapid quantitative test system provided results quickly and was easy to use, so that tests using this system can be easily performed at outpatient clinics or elsewhere. This system may also be useful for initial cancer screening and for point-of-care testing, because results can be obtained within 12 min and at a cost lower than that of conventional quantitative assays.

  16. Patient perceptions of receiving test results via online portals: a mixed-methods study.

    PubMed

    Giardina, Traber D; Baldwin, Jessica; Nystrom, Daniel T; Sittig, Dean F; Singh, Hardeep

    2018-04-01

    Online portals provide patients with access to their test results, but it is unknown how patients use these tools to manage results and what information is available to promote understanding. We conducted a mixed-methods study to explore patients' experiences and preferences when accessing their test results via portals. We conducted 95 interviews (13 semistructured and 82 structured) with adults who viewed a test result in their portal between April 2015 and September 2016 at 4 large outpatient clinics in Houston, Texas. Semistructured interviews were coded using content analysis and transformed into quantitative data and integrated with the structured interview data. Descriptive statistics were used to summarize the structured data. Nearly two-thirds (63%) did not receive any explanatory information or test result interpretation at the time they received the result, and 46% conducted online searches for further information about their result. Patients who received an abnormal result were more likely to experience negative emotions (56% vs 21%; P = .003) and more likely to call their physician (44% vs 15%; P = .002) compared with those who received normal results. Study findings suggest that online portals are not currently designed to present test results to patients in a meaningful way. Patients experienced negative emotions often with abnormal results, but sometimes even with normal results. Simply providing access via portals is insufficient; additional strategies are needed to help patients interpret and manage their online test results. Given the absence of national guidance, our findings could help strengthen policy and practice in this area and inform innovations that promote patient understanding of test results.

  17. Semi-quantitative MALDI-TOF for antimicrobial susceptibility testing in Staphylococcus aureus.

    PubMed

    Maxson, Tucker; Taylor-Howell, Cheryl L; Minogue, Timothy D

    2017-01-01

    Antibiotic resistant bacterial infections are a significant problem in the healthcare setting, in many cases requiring the rapid administration of appropriate and effective antibiotic therapy. Diagnostic assays capable of quickly and accurately determining the pathogen resistance profile are therefore crucial to initiate or modify care. Matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) is a standard method for species identification in many clinical microbiology laboratories and is well positioned to be applied towards antimicrobial susceptibility testing. One recently reported approach utilizes semi-quantitative MALDI-TOF MS for growth rate analysis to provide a resistance profile independent of resistance mechanism. This method was previously successfully applied to Gram-negative pathogens and mycobacteria; here, we evaluated this method with the Gram-positive pathogen Staphylococcus aureus. Specifically, we used 35 strains of S. aureus and four antibiotics to optimize and test the assay, resulting in an overall accuracy rate of 95%. Application of the optimized assay also successfully determined susceptibility from mock blood cultures, allowing both species identification and resistance determination for all four antibiotics within 3 hours of blood culture positivity.

  18. QUANTITATIVE TESTS OF ELMS AS INTERMEDIATE N PEELING-BALLOONING MODES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LAO, LL; SNYDER, PB; LEONARD, AW

    2002-07-01

    OAK A271 QUANTITATIVE TESTS OF ELMS AS INTERMEDIATE N PEELING-BALLOONING MODES. Two of the major issues crucial for the design of the next generation tokamak burning plasma devices are the predictability of the edge pedestal height and control of the divertor heat load in H-mode configurations. Both of these are strongly impacted by edge localized modes (ELMs) and their size. A working model for ELMs is that they are intermediate toroidal mode number, n {approx} 5-30, peeling-ballooning modes driven by the large edge pedestal pressure gradient P{prime} and the associated large edge bootstrap current density J{sub BS}. the interplay betweenmore » P{prime} and J{sub BS} as a discharge evolves can excite peeling-ballooning modes over a wide spectrum of n. The pedestal current density plays a dual role by stabilizing the high n ballooning modes via opening access to second stability but providing free energy to drive the intermediate n peeling modes. This makes a systematic evaluation of this model particularly challenging. This paper describes recent quantitative tests of this model using experimental data from the DIII-D and the JT-60U tokamaks. These tests are made possible by recent improvements to the ELITE MHD stability code, which allow an efficient evaluation of the unstable peeling-ballooning modes, as well as by improvements to other diagnostic and analysis techniques. Some of the key testable features of this model are: (1) ELMs are triggered when the growth rates of intermediate n MHD modes become significantly large; (2) ELM sizes are related to the radial widths of the unstable modes; (3) the unstable modes have a strong ballooning character localized in the outboard bad curvature region; (4) at high collisionality, ELM size generally becomes smaller because J{sub BS} is reduced.« less

  19. Comparison of quantitative and qualitative tests for glucose-6-phosphate dehydrogenase deficiency in the neonatal period.

    PubMed

    Keihanian, F; Basirjafari, S; Darbandi, B; Saeidinia, A; Jafroodi, M; Sharafi, R; Shakiba, M

    2017-06-01

    Considering the high prevalence of glucose-6-phosphate dehydrogenase (G6PD) deficiency among newborns, different screening methods have been established in various countries. In this study, we aimed to assess the prevalence of G6PD deficiency among newborns in Rasht, Iran, and compare G6PD activity in cord blood samples, using quantitative and qualitative tests. This cross-sectional, prospective study was performed at five largest hospitals in Rasht, Guilan Province, Iran. The screening tests were performed for all the newborns, referred to these hospitals. Specimens were characterized in terms of G6PD activity under ultraviolet light, using the kinetic method and the qualitative fluorescent spot test (FST). We also determined the sensitivity, specificity, negative predictive value, and positive predictive value of the qualitative assay. Blood samples were collected from 1474 newborns. Overall, 757 (51.4%) subjects were male. As the findings revealed, 1376 (93.4%) newborns showed normal G6PD activity, while 98 (6.6%) had G6PD deficiency. There was a significant difference in the mean G6PD level between males and females (P = 0.0001). Also, a significant relationship was detected between FST results and the mean values obtained in the quantitative test (P < 0.0001). According to the present study, FST showed acceptable sensitivity and specificity for G6PD activity, although it appeared inefficient for diagnostic purposes in some cases. © 2017 John Wiley & Sons Ltd.

  20. Patient perceptions of receiving test results via online portals: a mixed-methods study

    PubMed Central

    Giardina, Traber D; Baldwin, Jessica; Nystrom, Daniel T; Sittig, Dean F; Singh, Hardeep

    2018-01-01

    Abstract Objective Online portals provide patients with access to their test results, but it is unknown how patients use these tools to manage results and what information is available to promote understanding. We conducted a mixed-methods study to explore patients’ experiences and preferences when accessing their test results via portals. Materials and Methods We conducted 95 interviews (13 semistructured and 82 structured) with adults who viewed a test result in their portal between April 2015 and September 2016 at 4 large outpatient clinics in Houston, Texas. Semistructured interviews were coded using content analysis and transformed into quantitative data and integrated with the structured interview data. Descriptive statistics were used to summarize the structured data. Results Nearly two-thirds (63%) did not receive any explanatory information or test result interpretation at the time they received the result, and 46% conducted online searches for further information about their result. Patients who received an abnormal result were more likely to experience negative emotions (56% vs 21%; P = .003) and more likely to call their physician (44% vs 15%; P = .002) compared with those who received normal results. Discussion Study findings suggest that online portals are not currently designed to present test results to patients in a meaningful way. Patients experienced negative emotions often with abnormal results, but sometimes even with normal results. Simply providing access via portals is insufficient; additional strategies are needed to help patients interpret and manage their online test results. Conclusion Given the absence of national guidance, our findings could help strengthen policy and practice in this area and inform innovations that promote patient understanding of test results. PMID:29240899

  1. Comparison of Urine Albumin-to-Creatinine Ratio (ACR) Between ACR Strip Test and Quantitative Test in Prediabetes and Diabetes

    PubMed Central

    Cho, Seon; Kim, Suyoung; Cho, Han-Ik

    2017-01-01

    Background Albuminuria is generally known as a sensitive marker of renal and cardiovascular dysfunction. It can be used to help predict the occurrence of nephropathy and cardiovascular disorders in diabetes. Individuals with prediabetes have a tendency to develop macrovascular and microvascular pathology, resulting in an increased risk of retinopathy, cardiovascular diseases, and chronic renal diseases. We evaluated the clinical value of a strip test for measuring the urinary albumin-to-creatinine ratio (ACR) in prediabetes and diabetes. Methods Spot urine samples were obtained from 226 prediabetic and 275 diabetic subjects during regular health checkups. Urinary ACR was measured by using strip and laboratory quantitative tests. Results The positive rates of albuminuria measured by using the ACR strip test were 15.5% (microalbuminuria, 14.6%; macroalbuminuria, 0.9%) and 30.5% (microalbuminuria, 25.1%; macroalbuminuria, 5.5%) in prediabetes and diabetes, respectively. In the prediabetic population, the sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy of the ACR strip method were 92.0%, 94.0%, 65.7%, 99.0%, and 93.8%, respectively; the corresponding values in the diabetic population were 80.0%, 91.6%, 81.0%, 91.1%, and 88.0%, respectively. The median [interquartile range] ACR values in the strip tests for measurement ranges of <30, 30-300, and >300 mg/g were 9.4 [6.3-15.4], 46.9 [26.5-87.7], and 368.8 [296.2-575.2] mg/g, respectively, using the laboratory method. Conclusions The ACR strip test showed high sensitivity, specificity, and negative predictive value, suggesting that the test can be used to screen for albuminuria in cases of prediabetes and diabetes. PMID:27834062

  2. Scoring in genetically modified organism proficiency tests based on log-transformed results.

    PubMed

    Thompson, Michael; Ellison, Stephen L R; Owen, Linda; Mathieson, Kenneth; Powell, Joanne; Key, Pauline; Wood, Roger; Damant, Andrew P

    2006-01-01

    The study considers data from 2 UK-based proficiency schemes and includes data from a total of 29 rounds and 43 test materials over a period of 3 years. The results from the 2 schemes are similar and reinforce each other. The amplification process used in quantitative polymerase chain reaction determinations predicts a mixture of normal, binomial, and lognormal distributions dominated by the latter 2. As predicted, the study results consistently follow a positively skewed distribution. Log-transformation prior to calculating z-scores is effective in establishing near-symmetric distributions that are sufficiently close to normal to justify interpretation on the basis of the normal distribution.

  3. Quantitative investigation of ligament strains during physical tests for sacroiliac joint pain using finite element analysis.

    PubMed

    Kim, Yoon Hyuk; Yao, Zhidong; Kim, Kyungsoo; Park, Won Man

    2014-06-01

    It may be assumed that the stability is affected when some ligaments are injured or loosened, and this joint instability causes sacroiliac joint pain. Several physical examinations have been used to diagnose sacroiliac pain and to isolate the source of the pain. However, more quantitative and objective information may be necessary to identify unstable or injured ligaments during these tests due to the lack of understanding of the quantitative relationship between the physical tests and the biomechanical parameters that may be related to pains in the sacroiliac joint and the surrounding ligaments. In this study, a three-dimensional finite element model of the sacroiliac joint was developed and the biomechanical conditions for six typical physical tests such as the compression test, distraction test, sacral apex pressure test, thigh thrust test, Patrick's test, and Gaenslen's test were modelled. The sacroiliac joint contact pressure and ligament strain were investigated for each test. The values of contact pressure and the combination of most highly strained ligaments differed markedly among the tests. Therefore, these findings in combination with the physical tests would be helpful to identify the pain source and to understand the pain mechanism. Moreover, the technology provided in this study might be a useful tool to evaluate the physical tests, to improve the present test protocols, or to develop a new physical test protocol. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Parallel and serial computing tools for testing single-locus and epistatic SNP effects of quantitative traits in genome-wide association studies

    PubMed Central

    Ma, Li; Runesha, H Birali; Dvorkin, Daniel; Garbe, John R; Da, Yang

    2008-01-01

    Background Genome-wide association studies (GWAS) using single nucleotide polymorphism (SNP) markers provide opportunities to detect epistatic SNPs associated with quantitative traits and to detect the exact mode of an epistasis effect. Computational difficulty is the main bottleneck for epistasis testing in large scale GWAS. Results The EPISNPmpi and EPISNP computer programs were developed for testing single-locus and epistatic SNP effects on quantitative traits in GWAS, including tests of three single-locus effects for each SNP (SNP genotypic effect, additive and dominance effects) and five epistasis effects for each pair of SNPs (two-locus interaction, additive × additive, additive × dominance, dominance × additive, and dominance × dominance) based on the extended Kempthorne model. EPISNPmpi is the parallel computing program for epistasis testing in large scale GWAS and achieved excellent scalability for large scale analysis and portability for various parallel computing platforms. EPISNP is the serial computing program based on the EPISNPmpi code for epistasis testing in small scale GWAS using commonly available operating systems and computer hardware. Three serial computing utility programs were developed for graphical viewing of test results and epistasis networks, and for estimating CPU time and disk space requirements. Conclusion The EPISNPmpi parallel computing program provides an effective computing tool for epistasis testing in large scale GWAS, and the epiSNP serial computing programs are convenient tools for epistasis analysis in small scale GWAS using commonly available computer hardware. PMID:18644146

  5. Test 6, Test 7, and Gas Standard Analysis Results

    NASA Technical Reports Server (NTRS)

    Perez, Horacio, III

    2007-01-01

    This viewgraph presentation shows results of analyses on odor, toxic off gassing and gas standards. The topics include: 1) Statistical Analysis Definitions; 2) Odor Analysis Results NASA Standard 6001 Test 6; 3) Toxic Off gassing Analysis Results NASA Standard 6001 Test 7; and 4) Gas Standard Results NASA Standard 6001 Test 7;

  6. Collection of quantitative chemical release field data.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Demirgian, J.; Macha, S.; Loyola Univ.

    1999-01-01

    Detection and quantitation of chemicals in the environment requires Fourier-transform infrared (FTIR) instruments that are properly calibrated and tested. This calibration and testing requires field testing using matrices that are representative of actual instrument use conditions. Three methods commonly used for developing calibration files and training sets in the field are a closed optical cell or chamber, a large-scale chemical release, and a small-scale chemical release. There is no best method. The advantages and limitations of each method should be considered in evaluating field results. Proper calibration characterizes the sensitivity of an instrument, its ability to detect a component inmore » different matrices, and the quantitative accuracy and precision of the results.« less

  7. Cholesterol testing and results

    MedlinePlus

    ... profile results; Hyperlipidemia-results; Lipid disorder test results; Heart disease - cholesterol results ... at an earlier age if you have: Diabetes Heart disease Stroke High blood pressure A strong family history ...

  8. Quantitative urine confirmatory testing for synthetic cannabinoids in randomly collected urine specimens

    PubMed Central

    Castaneto, Marisol S.; Scheidweiler, Karl B.; Gandhi, Adarsh; Wohlfarth, Ariane; Klette, Kevin L.; Martin, Thomas M.; Huestis, Marilyn A.

    2014-01-01

    Synthetic cannabinoid intake is an ongoing health issue worldwide, with new compounds continually emerging, making drug testing complex. Parent synthetic cannabinoids are rarely detected in urine, the most common matrix employed in workplace drug testing. Optimal identification of synthetic cannabinoid markers in authentic urine specimens and correlation of metabolite concentrations and toxicities would improve synthetic cannabinoid result interpretation. We screened 20,017 randomly collected US military urine specimens between July 2011 and June 2012 with a synthetic cannabinoid immunoassay yielding 1,432 presumptive positive specimens. We analyzed all presumptive positive and 1,069 negative specimens with our qualitative synthetic cannabinoid LC-MS/MS method, which confirmed 290 positive specimens. All 290 positive and 487 randomly-selected negative specimens were quantified with the most comprehensive urine quantitative LC-MS/MS method published to date. 290 specimens confirmed positive for 22 metabolites from 11 parent synthetic cannabinoids. The five most predominant metabolites were JWH-018 pentanoic acid (93%), JWH-018 N-hydroxypentyl (84%), AM2201 N-hydroxypentyl (69%), JWH-073 butanoic acid (69%), and JWH-122 N-hydroxypentyl (45%) with 11.1 (0.1–2434), 5.1 (0.1–1239), 2.0 (0.1–321), 1.1 (0.1–48.6), and 1.1 (0.1–250) μg/L median (range) concentrations, respectively. Alkyl hydroxy and carboxy metabolites provided suitable biomarkers for 11 parent synthetic cannabinoids; although, hydroxyindoles also were observed. This is by far the largest data set of synthetic cannabinoid metabolites urine concentrations from randomly collected workplace drug testing specimens rather than acute intoxications or driving under the influence of drugs. These data improve the interpretation of synthetic cannabinoid urine test results and suggest suitable urine markers of synthetic cannabinoid intake. PMID:25231213

  9. Quantitative urine confirmatory testing for synthetic cannabinoids in randomly collected urine specimens.

    PubMed

    Castaneto, Marisol S; Scheidweiler, Karl B; Gandhi, Adarsh; Wohlfarth, Ariane; Klette, Kevin L; Martin, Thomas M; Huestis, Marilyn A

    2015-06-01

    Synthetic cannabinoid intake is an ongoing health issue worldwide, with new compounds continually emerging, making drug testing complex. Parent synthetic cannabinoids are rarely detected in urine, the most common matrix employed in workplace drug testing. Optimal identification of synthetic cannabinoid markers in authentic urine specimens and correlation of metabolite concentrations and toxicities would improve synthetic cannabinoid result interpretation. We screened 20 017 randomly collected US military urine specimens between July 2011 and June 2012 with a synthetic cannabinoid immunoassay yielding 1432 presumptive positive specimens. We analyzed all presumptive positive and 1069 negative specimens with our qualitative synthetic cannabinoid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, which confirmed 290 positive specimens. All 290 positive and 487 randomly selected negative specimens were quantified with the most comprehensive urine quantitative LC-MS/MS method published to date; 290 specimens confirmed positive for 22 metabolites from 11 parent synthetic cannabinoids. The five most predominant metabolites were JWH-018 pentanoic acid (93%), JWH-N-hydroxypentyl (84%), AM2201 N-hydroxypentyl (69%), JWH-073 butanoic acid (69%), and JWH-122 N-hydroxypentyl (45%) with 11.1 (0.1-2,434), 5.1 (0.1-1,239), 2.0 (0.1-321), 1.1 (0.1-48.6), and 1.1 (0.1-250) µg/L median (range) concentrations, respectively. Alkyl hydroxy and carboxy metabolites provided suitable biomarkers for 11 parent synthetic cannabinoids; although hydroxyindoles were also observed. This is by far the largest data set of synthetic cannabinoid metabolites urine concentrations from randomly collected workplace drug testing specimens rather than acute intoxications or driving under the influence of drugs. These data improve the interpretation of synthetic cannabinoid urine test results and suggest suitable urine markers of synthetic cannabinoid intake. This article is a U

  10. A low dose of three local anesthetic solutions for interscalene blockade tested by thermal quantitative sensory testing: a randomized controlled trial.

    PubMed

    Sermeus, Luc A; Schepens, Tom; Hans, Guy H; Morrison, Stuart G; Wouters, Kristien; Breebaart, Margaretha B; Smitz, Carine J; Vercauteren, Marcel P

    2018-05-03

    This randomized double-blind controlled trial compared the block characteristics of three low-dose local anesthetics at different roots in an ultrasound-guided interscalene block, using thermal quantitative sensory testing for assessing the functioning of cutaneous small nerve fibres. A total of 37 adults scheduled to undergo shoulder arthroscopy were randomized to receive 5 mL of either 0.5% levobupivacaine with and without epinephrine 1/200,000 or 0.75% ropivacaine in a single-shot interscalene block. Thermal quantitative sensory testing was performed in the C4, C5, C6 and C7 dermatomes. Detection thresholds for cold/warm sensation and cold/heat pain were measured before and at 30 min, 6, 10 and 24 h after infiltration around C5. The need for rescue medication was recorded. No significant differences between groups were found for any sensation (lowest P = 0.28). At 6 h, the largest differences in sensory thresholds were observed for the C5 dermatome. The increase in thresholds were less in C4 and C6 and minimal in C7 for all sensations. The analgesic effect lasted the longest in C5 (time × location mixed model P < 0.001 for all sensory tests). The time to rescue analgesia was significantly shorter with 0.75% ropivacaine (P = 0.02). The quantitative sensory findings showed no difference in intensity between the local anesthetics tested. A decrease in block intensity, with minimal changes in pain detection thresholds, was observed in the roots adjacent to C5, with the lowest block intensity in C7. A clinically relevant shorter duration was found with 0.75% ropivacaine compared to the other groups. Trial registration NCT 02691442.

  11. Quantitative comparison of the results obtained by the multiple-dose guinea pig maximization test and the non-radioactive murine local lymph-node assay for various biocides.

    PubMed

    Yamano, Tetsuo; Shimizu, Mitsuru; Noda, Tsutomu

    2005-07-01

    We compared the results of the multiple-dose guinea pig maximization test (GPMT) and the non-radioactive murine local lymph-node assay (LLNA) for various biocides. Thirteen out of 17 positive biocides in the GPMT gave positive results in the LLNA. In the GPMT, the minimum first induction doses ranged over four orders (0.00005-0.5%), while elicitation-threshold doses, which were evaluated using an optimally sensitized group of animals in the multiple-dose studies, ranged over five orders (0.00006-2.8%). In the LLNA, minimum induction doses ranged over more than three orders (0.01-30%). With respect to 13 biocides that were positive in both the GPMT and the LLNA, results were quantitatively compared. When compared after conversion to corresponding area doses (microg/cm), the minimum doses required to elicit skin reaction in guinea pigs were always lower than that for induction in mice with all biocides. Correlation between minimum induction doses from the GPMT and the LLNA seemed poor (r=0.57), while that between minimum induction doses in the LLNA and elicitation-threshold doses in the GPMT was relatively good (r=0.73). The results suggest the possibility to estimate human elicitation-threshold doses, which are definitely lacking in the process of risk assessment for skin-sensitizers, from the data of the LLNA.

  12. Workarounds and Test Results Follow-up in Electronic Health Record-Based Primary Care

    PubMed Central

    Menon, Shailaja; Murphy, Daniel R.; Singh, Hardeep; Meyer, Ashley N. D.

    2016-01-01

    Summary Background Electronic health records (EHRs) have potential to facilitate reliable communication and follow-up of test results. However, limitations in EHR functionality remain, leading practitioners to use workarounds while managing test results. Workarounds can lead to patient safety concerns and signify indications as to how to build better EHR systems that meet provider needs. Objective To understand why primary care practitioners (PCPs) use workarounds to manage test results by analyzing data from a previously conducted national cross-sectional survey on test result management. Methods We conducted a secondary data analysis of quantitative and qualitative data from a national survey of PCPs practicing in the Department of Veterans Affairs (VA) and explored the use of workarounds in test results management. We used multivariate logistic regression analysis to examine the association between key sociotechnical factors that could affect test results follow-up (e.g., both technology-related and those unrelated to technology, such as organizational support for patient notification) and workaround use. We conducted a qualitative content analysis of free text survey data to examine reasons for use of workarounds. Results Of 2554 survey respondents, 1104 (43%) reported using workarounds related to test results management. Of these 1028 (93%) described the type of workaround they were using; 719 (70%) reported paper-based methods, while 230 (22%) used a combination of paper- and computer-based workarounds. Primary care practitioners who self-reported limited administrative support to help them notify patients of test results or described an instance where they personally (or a colleague) missed results, were more likely to use workarounds (p=0.02 and p=0.001, respectively). Qualitative analysis identified three main reasons for workaround use: 1) as a memory aid, 2) for improved efficiency and 3) for facilitating internal and external care coordination

  13. Multispectral colour analysis for quantitative evaluation of pseudoisochromatic color deficiency tests

    NASA Astrophysics Data System (ADS)

    Ozolinsh, Maris; Fomins, Sergejs

    2010-11-01

    Multispectral color analysis was used for spectral scanning of Ishihara and Rabkin color deficiency test book images. It was done using tunable liquid-crystal LC filters built in the Nuance II analyzer. Multispectral analysis keeps both, information on spatial content of tests and on spectral content. Images were taken in the range of 420-720nm with a 10nm step. We calculated retina neural activity charts taking into account cone sensitivity functions, and processed charts in order to find the visibility of latent symbols in color deficiency plates using cross-correlation technique. In such way the quantitative measure is found for each of diagnostics plate for three different color deficiency carrier types - protanopes, deutanopes and tritanopes. Multispectral color analysis allows to determine the CIE xyz color coordinates of pseudoisochromatic plate design elements and to perform statistical analysis of these data to compare the color quality of available color deficiency test books.

  14. Quantitative Improvements in Hop Test Scores After a 6-Week Neuromuscular Training Program.

    PubMed

    Meierbachtol, Adam; Rohman, Eric; Paur, Eric; Bottoms, John; Tompkins, Marc

    2016-09-12

    In patients who have undergone anterior cruciate ligament reconstruction (ACLR), the effect of neuromuscular re-education (NMR) programs on standard hop tests outcomes, including limb symmetry indices (LSIs), is unknown. Both legs will show improvement in hop test-measured units after neuromuscular training, but the involved leg will show relatively greater improvement leading to improved limb symmetry. Patients younger than 18 years will show more improvement than patients who are older. Retrospective cohort study. Level 3. Patients self-selected their participation in this NMR program, which was completed after traditional outpatient physical therapy. Pre- and post-hop test scores were recorded as the primary outcome measure. Seventy-one patients met the inclusion criteria and completed hop testing. Overall, the involved leg showed significant improvements (pretest/posttest) for single-leg hop (138.30 cm/156.89 cm), triple crossover hop (370.05 cm/423.11 cm), and timed hop (2.21 s/1.99 s). Similarly, on the uninvolved leg, improvements were seen for the single-leg hop (159.30 cm/171.87 cm) and triple crossover hop (427.50 cm/471.27 cm). Overall mean limb symmetry improved across all 4 hop tests, but there was significant improvement only on the single-leg hop (87% pretest to 92% posttest). Patients younger than 18 years showed mean significant LSI improvement on the triple crossover hop. Utilizing an intensive 6-week NMR program after ACLR prior to return to sport can improve quantitative hop test measurements. Patients younger than 18 years had greater improvement than those 18 years and older. Advanced NMR programs can be successfully utilized in the postoperative ACLR setting to improve quantitative limb symmetry. © 2016 The Author(s).

  15. Workarounds and Test Results Follow-up in Electronic Health Record-Based Primary Care.

    PubMed

    Menon, Shailaja; Murphy, Daniel R; Singh, Hardeep; Meyer, Ashley N D; Sittig, Dean F

    2016-01-01

    Electronic health records (EHRs) have potential to facilitate reliable communication and follow-up of test results. However, limitations in EHR functionality remain, leading practitioners to use workarounds while managing test results. Workarounds can lead to patient safety concerns and signify indications as to how to build better EHR systems that meet provider needs. To understand why primary care practitioners (PCPs) use workarounds to manage test results by analyzing data from a previously conducted national cross-sectional survey on test result management. We conducted a secondary data analysis of quantitative and qualitative data from a national survey of PCPs practicing in the Department of Veterans Affairs (VA) and explored the use of workarounds in test results management. We used multivariate logistic regression analysis to examine the association between key sociotechnical factors that could affect test results follow-up (e.g., both technology-related and those unrelated to technology, such as organizational support for patient notification) and workaround use. We conducted a qualitative content analysis of free text survey data to examine reasons for use of workarounds. Of 2554 survey respondents, 1104 (43%) reported using workarounds related to test results management. Of these 1028 (93%) described the type of workaround they were using; 719 (70%) reported paper-based methods, while 230 (22%) used a combination of paper- and computer-based workarounds. Primary care practitioners who self-reported limited administrative support to help them notify patients of test results or described an instance where they personally (or a colleague) missed results, were more likely to use workarounds (p=0.02 and p=0.001, respectively). Qualitative analysis identified three main reasons for workaround use: 1) as a memory aid, 2) for improved efficiency and 3) for facilitating internal and external care coordination. Workarounds to manage EHR-based test results are

  16. Quantitative determination of dimethicone in commercial tablets and capsules by Fourier transform infrared spectroscopy and antifoaming activity test.

    PubMed

    Torrado, G; García-Arieta, A; de los Ríos, F; Menéndez, J C; Torrado, S

    1999-03-01

    Fourier transform infrared (FTIR) spectroscopy and antifoaming activity test have been employed for the quantitative analysis of dimethicone. Linearity, accuracy and precision are presented for both methods. These methods have been also used to compare different dimethicone-containing proprietary medicines. FTIR spectroscopy has shown to be adequate for quantitation of dimethicone in commercial tablets and capsules in order to comply with USP requirements. The antifoaming activity test is able to detect incompatibilities between dimethicone and other constituents. The presence of certain enzymes in some medicinal products increases the defoaming properties of these formulations.

  17. Quantitative fetal fibronectin testing in combination with cervical length measurement in the prediction of spontaneous preterm delivery in symptomatic women.

    PubMed

    Bruijn, Mmc; Vis, J Y; Wilms, F F; Oudijk, M A; Kwee, A; Porath, M M; Oei, G; Scheepers, Hcj; Spaanderman, Mea; Bloemenkamp, Kwm; Haak, M C; Bolte, A C; Vandenbussche, Fpha; Woiski, M D; Bax, C J; Cornette, Jmj; Duvekot, J J; Nij Bijvanck, Bwa; van Eyck, J; Franssen, Mtm; Sollie, K M; van der Post, Jam; Bossuyt, Pmm; Opmeer, B C; Kok, M; Mol, Bwj; van Baaren, G-J

    2016-11-01

    To evaluate whether in symptomatic women, the combination of quantitative fetal fibronectin (fFN) testing and cervical length (CL) improves the prediction of preterm delivery (PTD) within 7 days compared with qualitative fFN and CL. Post hoc analysis of frozen fFN samples of a nationwide cohort study. Ten perinatal centres in the Netherlands. Symptomatic women between 24 and 34 weeks of gestation. The risk of PTD <7 days was estimated in predefined CL and fFN strata. We used logistic regression to develop a model including quantitative fFN and CL, and one including qualitative fFN (threshold 50 ng/ml) and CL. We compared the models' capacity to identify women at low risk (<5%) for delivery within 7 days using a reclassification table. Spontaneous delivery within 7 days after study entry. We studied 350 women, of whom 69 (20%) delivered within 7 days. The risk of PTD in <7 days ranged from 2% in the lowest fFN group (<10 ng/ml) to 71% in the highest group (>500 ng/ml). Multivariable logistic regression showed an increasing risk of PTD in <7 days with rising fFN concentration [10-49 ng/ml: odds ratio (OR) 1.3, 95% confidence interval (95% CI) 0.23-7.0; 50-199 ng/ml: OR 3.2, 95% CI 0.79-13; 200-499 ng/ml: OR 9.0, 95% CI 2.3-35; >500 ng/ml: OR 39, 95% CI 9.4-164] and shortening of the CL (OR 0.86 per mm, 95% CI 0.82-0.90). Use of quantitative fFN instead of qualitative fFN resulted in reclassification of 18 (5%) women from high to low risk, of whom one (6%) woman delivered within 7 days. In symptomatic women, quantitative fFN testing does not improve the prediction of PTD within 7 days compared with qualitative fFN testing in combination with CL measurement in terms of reclassification from high to low (<5%) risk, but it adds value across the risk range. Quantitative fFN testing adds value to qualitative fFN testing with CL measurement in the prediction of PTD. © 2015 Royal College of Obstetricians and Gynaecologists.

  18. Continuous wavelet transforms for the simultaneous quantitative analysis and dissolution testing of lamivudine-zidovudine tablets.

    PubMed

    Dinç, Erdal; Özdemir, Nurten; Üstündağ, Özgür; Tilkan, Müşerref Günseli

    2013-01-01

    Dissolution testing has a very vital importance for a quality control test and prediction of the in vivo behavior of the oral dosage formulation. This requires the use of a powerful analytical method to get reliable, accurate and precise results for the dissolution experiments. In this context, new signal processing approaches, continuous wavelet transforms (CWTs) were improved for the simultaneous quantitative estimation and dissolution testing of lamivudine (LAM) and zidovudine (ZID) in a tablet dosage form. The CWT approaches are based on the application of the continuous wavelet functions to the absorption spectra-data vectors of LAM and ZID in the wavelet domain. After applying many wavelet functions, the families consisting of Mexican hat wavelet with the scaling factor a=256, Symlets wavelet with the scaling factor a=512 and the order of 5 and Daubechies wavelet at the scale factor a=450 and the order of 10 were found to be suitable for the quantitative determination of the mentioned drugs. These wavelet applications were named as mexh-CWT, sym5-CWT and db10-CWT methods. Calibration graphs for LAM and ZID in the working range of 2.0-50.0 µg/mL and 2.0-60.0 µg/mL were obtained measuring the mexh-CWT, sym5-CWT and db10-CWT amplitudes at the wavelength points corresponding to zero crossing points. The validity and applicability of the improved mexh-CWT, sym5-CWT and db10-CWT approaches was carried out by the analysis of the synthetic mixtures containing the analyzed drugs. Simultaneous determination of LAM and ZID in tablets was accomplished by the proposed CWT methods and their dissolution profiles were graphically explored.

  19. Providing Quantitative Information and a Nudge to Undergo Stool Testing in a Colorectal Cancer Screening Decision Aid: A Randomized Clinical Trial.

    PubMed

    Schwartz, Peter H; Perkins, Susan M; Schmidt, Karen K; Muriello, Paul F; Althouse, Sandra; Rawl, Susan M

    2017-08-01

    Guidelines recommend that patient decision aids should provide quantitative information about probabilities of potential outcomes, but the impact of this information is unknown. Behavioral economics suggests that patients confused by quantitative information could benefit from a "nudge" towards one option. We conducted a pilot randomized trial to estimate the effect sizes of presenting quantitative information and a nudge. Primary care patients (n = 213) eligible for colorectal cancer screening viewed basic screening information and were randomized to view (a) quantitative information (quantitative module), (b) a nudge towards stool testing with the fecal immunochemical test (FIT) (nudge module), (c) neither a nor b, or (d) both a and b. Outcome measures were perceived colorectal cancer risk, screening intent, preferred test, and decision conflict, measured before and after viewing the decision aid, and screening behavior at 6 months. Patients viewing the quantitative module were more likely to be screened than those who did not ( P = 0.012). Patients viewing the nudge module had a greater increase in perceived colorectal cancer risk than those who did not ( P = 0.041). Those viewing the quantitative module had a smaller increase in perceived risk than those who did not ( P = 0.046), and the effect was moderated by numeracy. Among patients with high numeracy who did not view the nudge module, those who viewed the quantitative module had a greater increase in intent to undergo FIT ( P = 0.028) than did those who did not. The limitations of this study were the limited sample size and single healthcare system. Adding quantitative information to a decision aid increased uptake of colorectal cancer screening, while adding a nudge to undergo FIT did not increase uptake. Further research on quantitative information in decision aids is warranted.

  20. 40 CFR 799.12 - Test results.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Test results. 799.12 Section 799.12... results. Except as set forth in specific chemical test rules in subpart B of this part, a positive or negative test result in any of the tests required under subpart B is defined in the TSCA test guidelines...

  1. 40 CFR 799.12 - Test results.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 33 2013-07-01 2013-07-01 false Test results. 799.12 Section 799.12... results. Except as set forth in specific chemical test rules in subpart B of this part, a positive or negative test result in any of the tests required under subpart B is defined in the TSCA test guidelines...

  2. 40 CFR 799.12 - Test results.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 33 2012-07-01 2012-07-01 false Test results. 799.12 Section 799.12... results. Except as set forth in specific chemical test rules in subpart B of this part, a positive or negative test result in any of the tests required under subpart B is defined in the TSCA test guidelines...

  3. Influence of aging on thermal and vibratory thresholds of quantitative sensory testing.

    PubMed

    Lin, Yea-Huey; Hsieh, Song-Chou; Chao, Chi-Chao; Chang, Yang-Chyuan; Hsieh, Sung-Tsang

    2005-09-01

    Quantitative sensory testing has become a common approach to evaluate thermal and vibratory thresholds in various types of neuropathies. To understand the effect of aging on sensory perception, we measured warm, cold, and vibratory thresholds by performing quantitative sensory testing on a population of 484 normal subjects (175 males and 309 females), aged 48.61 +/- 14.10 (range 20-86) years. Sensory thresholds of the hand and foot were measured with two algorithms: the method of limits (Limits) and the method of level (Level). Thresholds measured by Limits are reaction-time-dependent, while those measured by Level are independent of reaction time. In addition, we explored (1) the correlations of thresholds between these two algorithms, (2) the effect of age on differences in thresholds between algorithms, and (3) differences in sensory thresholds between the two test sites. Age was consistently and significantly correlated with sensory thresholds of all tested modalities measured by both algorithms on multivariate regression analysis compared with other factors, including gender, body height, body weight, and body mass index. When thresholds were plotted against age, slopes differed between sensory thresholds of the hand and those of the foot: for the foot, slopes were steeper compared with those for the hand for each sensory modality. Sensory thresholds of both test sites measured by Level were highly correlated with those measured by Limits, and thresholds measured by Limits were higher than those measured by Level. Differences in sensory thresholds between the two algorithms were also correlated with age: thresholds of the foot were higher than those of the hand for each sensory modality. This difference in thresholds (measured with both Level and Limits) between the hand and foot was also correlated with age. These findings suggest that age is the most significant factor in determining sensory thresholds compared with the other factors of gender and

  4. QUANTITATIVE ASPECTS OF THE RED BLOOD CELL AGGLUTINATION TEST FOR INFLUENZA VIRUS

    PubMed Central

    Miller, Gail Lorenz; Stanley, W. M.

    1944-01-01

    A detailed study has been made of the nature of the variables inherent in the chicken red cell agglutination test for influenza virus in an effort to obtain a method of measurement of biological activity of sufficient accuracy that it might be employed as a reliable index of chemical purity of preparations of the virus. It was found that the temperature at which the test is conducted has a marked effect on the titer, whereas within the range of pH 6–8 the pH has a negligible effect. It was also found that a variation in results may be encountered due to a variation in the specific behavior of red cells from different chickens and to an instability of the red cells themselves. Preparations of purified influenza virus held at 4°C., on the other hand, were found to be stable with respect to chicken red cell agglutinating activity for several months. This fact, together with the fact that in duplicate measurements upon different samples the accuracy was such that the chances were 19 out of 20 that differences of 8.4 per cent in the mean end points were significant, made it possible to establish a reproducible standard of CCA activity based on a unit weight of purified virus material. As a result, it was possible to devise a standardized procedure for carrying out with high accuracy quantitative measurements of influenza virus. PMID:19871362

  5. Gene-Based Testing of Interactions in Association Studies of Quantitative Traits

    PubMed Central

    Ma, Li; Clark, Andrew G.; Keinan, Alon

    2013-01-01

    Various methods have been developed for identifying gene–gene interactions in genome-wide association studies (GWAS). However, most methods focus on individual markers as the testing unit, and the large number of such tests drastically erodes statistical power. In this study, we propose novel interaction tests of quantitative traits that are gene-based and that confer advantage in both statistical power and biological interpretation. The framework of gene-based gene–gene interaction (GGG) tests combine marker-based interaction tests between all pairs of markers in two genes to produce a gene-level test for interaction between the two. The tests are based on an analytical formula we derive for the correlation between marker-based interaction tests due to linkage disequilibrium. We propose four GGG tests that extend the following P value combining methods: minimum P value, extended Simes procedure, truncated tail strength, and truncated P value product. Extensive simulations point to correct type I error rates of all tests and show that the two truncated tests are more powerful than the other tests in cases of markers involved in the underlying interaction not being directly genotyped and in cases of multiple underlying interactions. We applied our tests to pairs of genes that exhibit a protein–protein interaction to test for gene-level interactions underlying lipid levels using genotype data from the Atherosclerosis Risk in Communities study. We identified five novel interactions that are not evident from marker-based interaction testing and successfully replicated one of these interactions, between SMAD3 and NEDD9, in an independent sample from the Multi-Ethnic Study of Atherosclerosis. We conclude that our GGG tests show improved power to identify gene-level interactions in existing, as well as emerging, association studies. PMID:23468652

  6. Interpretation of Negative Molecular Test Results in Patients With Suspected or Confirmed Ebola Virus Disease: Report of Two Cases.

    PubMed

    Edwards, Jeffrey K; Kleine, Christian; Munster, Vincent; Giuliani, Ruggero; Massaquoi, Moses; Sprecher, Armand; Chertow, Daniel S

    2015-12-01

    Quantitative reverse-transcription polymerase chain reaction (qRT-PCR) is the most sensitive quantitative diagnostic assay for detection of Ebola virus in multiple body fluids. Despite the strengths of this assay, we present 2 cases of Ebola virus disease (EVD) and highlight the potential for false-negative results during the early and late stages of EVD. The first case emphasizes the low negative-predictive value of qRT-PCR during incubation and the early febrile stage of EVD, and the second case emphasizes the potential for false-negative results during recovery and late neurologic complications of EVD. Careful interpretation of test results are needed to guide difficult admission and discharge decisions in suspected or confirmed EVD.

  7. Discrepancies between qualitative and quantitative evaluation of randomised controlled trial results: achieving clarity through mixed methods triangulation.

    PubMed

    Tonkin-Crine, Sarah; Anthierens, Sibyl; Hood, Kerenza; Yardley, Lucy; Cals, Jochen W L; Francis, Nick A; Coenen, Samuel; van der Velden, Alike W; Godycki-Cwirko, Maciek; Llor, Carl; Butler, Chris C; Verheij, Theo J M; Goossens, Herman; Little, Paul

    2016-05-12

    Mixed methods are commonly used in health services research; however, data are not often integrated to explore complementarity of findings. A triangulation protocol is one approach to integrating such data. A retrospective triangulation protocol was carried out on mixed methods data collected as part of a process evaluation of a trial. The multi-country randomised controlled trial found that a web-based training in communication skills (including use of a patient booklet) and the use of a C-reactive protein (CRP) point-of-care test decreased antibiotic prescribing by general practitioners (GPs) for acute cough. The process evaluation investigated GPs' and patients' experiences of taking part in the trial. Three analysts independently compared findings across four data sets: qualitative data collected view semi-structured interviews with (1) 62 patients and (2) 66 GPs and quantitative data collected via questionnaires with (3) 2886 patients and (4) 346 GPs. Pairwise comparisons were made between data sets and were categorised as agreement, partial agreement, dissonance or silence. Three instances of dissonance occurred in 39 independent findings. GPs and patients reported different views on the use of a CRP test. GPs felt that the test was useful in convincing patients to accept a no-antibiotic decision, but patient data suggested that this was unnecessary if a full explanation was given. Whilst qualitative data indicated all patients were generally satisfied with their consultation, quantitative data indicated highest levels of satisfaction for those receiving a detailed explanation from their GP with a booklet giving advice on self-care. Both qualitative and quantitative data sets indicated higher patient enablement for those in the communication groups who had received a booklet. Use of CRP tests does not appear to engage patients or influence illness perceptions and its effect is more centred on changing clinician behaviour. Communication skills and the patient

  8. Genotypic tropism testing by massively parallel sequencing: qualitative and quantitative analysis.

    PubMed

    Däumer, Martin; Kaiser, Rolf; Klein, Rolf; Lengauer, Thomas; Thiele, Bernhard; Thielen, Alexander

    2011-05-13

    Inferring viral tropism from genotype is a fast and inexpensive alternative to phenotypic testing. While being highly predictive when performed on clonal samples, sensitivity of predicting CXCR4-using (X4) variants drops substantially in clinical isolates. This is mainly attributed to minor variants not detected by standard bulk-sequencing. Massively parallel sequencing (MPS) detects single clones thereby being much more sensitive. Using this technology we wanted to improve genotypic prediction of coreceptor usage. Plasma samples from 55 antiretroviral-treated patients tested for coreceptor usage with the Monogram Trofile Assay were sequenced with standard population-based approaches. Fourteen of these samples were selected for further analysis with MPS. Tropism was predicted from each sequence with geno2pheno[coreceptor]. Prediction based on bulk-sequencing yielded 59.1% sensitivity and 90.9% specificity compared to the trofile assay. With MPS, 7600 reads were generated on average per isolate. Minorities of sequences with high confidence in CXCR4-usage were found in all samples, irrespective of phenotype. When using the default false-positive-rate of geno2pheno[coreceptor] (10%), and defining a minority cutoff of 5%, the results were concordant in all but one isolate. The combination of MPS and coreceptor usage prediction results in a fast and accurate alternative to phenotypic assays. The detection of X4-viruses in all isolates suggests that coreceptor usage as well as fitness of minorities is important for therapy outcome. The high sensitivity of this technology in combination with a quantitative description of the viral population may allow implementing meaningful cutoffs for predicting response to CCR5-antagonists in the presence of X4-minorities.

  9. Comparative Performance of Reagents and Platforms for Quantitation of Cytomegalovirus DNA by Digital PCR

    PubMed Central

    Gu, Z.; Sam, S. S.; Sun, Y.; Tang, L.; Pounds, S.; Caliendo, A. M.

    2016-01-01

    A potential benefit of digital PCR is a reduction in result variability across assays and platforms. Three sets of PCR reagents were tested on two digital PCR systems (Bio-Rad and RainDance), using three different sets of PCR reagents for quantitation of cytomegalovirus (CMV). Both commercial quantitative viral standards and 16 patient samples (n = 16) were tested. Quantitative accuracy (compared to nominal values) and variability were determined based on viral standard testing results. Quantitative correlation and variability were assessed with pairwise comparisons across all reagent-platform combinations for clinical plasma sample results. The three reagent sets, when used to assay quantitative standards on the Bio-Rad system, all showed a high degree of accuracy, low variability, and close agreement with one another. When used on the RainDance system, one of the three reagent sets appeared to have a much better correlation to nominal values than did the other two. Quantitative results for patient samples showed good correlation in most pairwise comparisons, with some showing poorer correlations when testing samples with low viral loads. Digital PCR is a robust method for measuring CMV viral load. Some degree of result variation may be seen, depending on platform and reagents used; this variation appears to be greater in samples with low viral load values. PMID:27535685

  10. Timed function tests, motor function measure, and quantitative thigh muscle MRI in ambulant children with Duchenne muscular dystrophy: A cross-sectional analysis.

    PubMed

    Schmidt, Simone; Hafner, Patricia; Klein, Andrea; Rubino-Nacht, Daniela; Gocheva, Vanya; Schroeder, Jonas; Naduvilekoot Devasia, Arjith; Zuesli, Stephanie; Bernert, Guenther; Laugel, Vincent; Bloetzer, Clemens; Steinlin, Maja; Capone, Andrea; Gloor, Monika; Tobler, Patrick; Haas, Tanja; Bieri, Oliver; Zumbrunn, Thomas; Fischer, Dirk; Bonati, Ulrike

    2018-01-01

    The development of new therapeutic agents for the treatment of Duchenne muscular dystrophy has put a focus on defining outcome measures most sensitive to capture treatment effects. This cross-sectional analysis investigates the relation between validated clinical assessments such as the 6-minute walk test, motor function measure and quantitative muscle MRI of thigh muscles in ambulant Duchenne muscular dystrophy patients, aged 6.5 to 10.8 years (mean 8.2, SD 1.1). Quantitative muscle MRI included the mean fat fraction using a 2-point Dixon technique, and transverse relaxation time (T2) measurements. All clinical assessments were highly significantly inter-correlated with p < 0.001. The strongest correlation with the motor function measure and its D1-subscore was shown by the 6-minute walk test. Clinical assessments showed no correlation with age. Importantly, quantitative muscle MRI values significantly correlated with all clinical assessments with the extensors showing the strongest correlation. In contrast to the clinical assessments, quantitative muscle MRI values were highly significantly correlated with age. In conclusion, the motor function measure and timed function tests measure disease severity in a highly comparable fashion and all tests correlated with quantitative muscle MRI values quantifying fatty muscle degeneration. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Quantitative assessment of drawing tests in children with dyslexia and dysgraphia.

    PubMed

    Galli, Manuela; Cimolin, Veronica; Stella, Giacomo; De Pandis, Maria Francesca; Ancillao, Andrea; Condoluci, Claudia

    2018-05-07

    Drawing tests in children diagnosed with dyslexia and dysgraphia were quantitatively compared. Fourteen children with dysgraphia, 19 with dyslexia and 13 normally developing were asked to copy 3 figures: a circle, a square and a cross. An optoelectronic system allowed the acquisition of the drawing track in three-dimensions. The participants' head position and upper limb movements were measured as well. A set of parameters including movement duration, velocity, length of the trace, Range of Motion of the upper limb, was computed and compared among the 3 groups. Children with dyslexia traced the circle faster than the other groups. In the cross test, dyslexic participants showed a reduced execution time and increased velocity while drawing the horizontal line. Children with dyslexia were also faster in drawing certain sides of square with respect to the other groups. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Quantitative analysis of cytomegalovirus (CMV) viremia using the pp65 antigenemia assay and the COBAS AMPLICOR CMV MONITOR PCR test after blood and marrow allogeneic transplantation.

    PubMed

    Boivin, G; Bélanger, R; Delage, R; Béliveau, C; Demers, C; Goyette, N; Roy, J

    2000-12-01

    The performance of a commercially available qualitative PCR test for plasma (AMPLICOR CMV Test; Roche Diagnostics) and a quantitative PCR test for plasma and leukocytes (COBAS AMPLICOR CMV MONITOR Test; Roche Diagnostics) was evaluated with samples from 50 blood or marrow allogeneic transplant recipients who received short courses of sequential ganciclovir therapy (2 weeks intravenously followed by 2 weeks orally) based on a positive cytomegalovirus (CMV) pp65 antigenemia (AG) assay. The number of persons with a positive CMV test was significantly higher for leukocyte-based assays (AG, 67.5%; PCR, 62.5%) compared to both quantitative and qualitative PCR tests of plasma (42.5 and 35%, respectively). One person developed CMV disease during the study despite a negative AG assay; in this particular case, all PCR assays were found to be positive 10 days before his death. There was a trend for earlier positivity after transplantation and more rapid negativity after initiation of ganciclovir for the tests performed on leukocytes. The mean number of CMV copies as assessed by PCR was significantly higher in leukocytes than in plasma (P = 0.02). Overall, excellent agreement (kappa coefficient, >0.75) was found only between the two PCR assays (qualitative and quantitative) based on plasma. These results suggest that either the pp65 AG assay or the COBAS AMPLICOR CMV MONITOR Test using leukocytes could be used to safely monitor CMV viremia in related allogeneic blood or marrow transplant recipients. Such a strategy will result in preemptive treatment for about two-thirds of the persons with a relatively low rate (<33%) of secondary viremic episodes following short courses of ganciclovir therapy.

  13. Quantitative analysis of the pendulum test: application to multiple sclerosis patients treated with botulinum toxin.

    PubMed

    Bianchi, L; Monaldi, F; Paolucci, S; Iani, C; Lacquaniti, F

    1999-01-01

    The aim of this study was to develop quantitative analytical methods in the application of the pendulum test to both normal and spastic subjects. The lower leg was released by a torque motor from different starting positions. The resulting changes in the knee angle were fitted by means of a time-varying model. Stiffness and viscosity coefficients were derived for each half-cycle oscillation in both flexion and extension, and for all knee starting positions. This method was applied to the assessment of the effects of Botulinum toxin A (BTX) in progressive multiple sclerosis patients in a follow-up study. About half of the patients showed a significant decrement in stiffness and viscosity coefficients.

  14. Pregnancy Tests

    MedlinePlus

    ... one or both types of blood tests: A quantitative blood test (also called a beta hCG test) ... taking the test to check the results window. Research suggests that waiting 10 minutes will give the ...

  15. Viral drug sensitivity testing using quantitative PCR: effect of tyrosine kinase inhibitors on polyomavirus BK replication.

    PubMed

    Randhawa, Parmjeet S; Farasati, Noush A; Huang, Yuchen; Mapara, Markus Y; Shapiro, Ron

    2010-12-01

    Our objective was to determine whether quantitative polymerase chain reaction (PCR) can be used to measure the effect of tyrosine kinase (TK) inhibition on polyomavirus BK (BKV) replication. The BKV was grown in a cell culture system. The rate of viral replication in the presence or absence of the drug being tested was assessed by amplifying the viral genome using primers directed against the viral capsid 1 protein. Dasatinib, erlotinib, gefitinib, imatinib, sunitinib, and sorafenib all showed antiviral activity at micromolar concentrations. The 50% effective concentration for erlotinib and sorafenib was within blood concentrations readily achieved in human subjects. Quantitative PCR is a convenient method for viral drug sensitivity testing for slow-growing viruses that do not readily produce cytopathic effect. TK inhibitors deserve further consideration as a potential therapeutic option for BKV-associated nephropathy and hemorrhagic cystitis.

  16. What Really Happens in Quantitative Group Research? Results of a Content Analysis of Recent Quantitative Research in "JSGW"

    ERIC Educational Resources Information Center

    Boyle, Lauren H.; Whittaker, Tiffany A.; Eyal, Maytal; McCarthy, Christopher J.

    2017-01-01

    The authors conducted a content analysis on quantitative studies published in "The Journal for Specialists in Group Work" ("JSGW") between 2012 and 2015. This brief report provides a general overview of the current practices of quantitative group research in counseling. The following study characteristics are reported and…

  17. Revisiting susceptibility testing in MDR-TB by a standardized quantitative phenotypic assessment in a European multicentre study.

    PubMed

    Cambau, E; Viveiros, M; Machado, D; Raskine, L; Ritter, C; Tortoli, E; Matthys, V; Hoffner, S; Richter, E; Perez Del Molino, M L; Cirillo, D M; van Soolingen, D; Böttger, E C

    2015-03-01

    Treatment outcome of MDR-TB is critically dependent on the proper use of second-line drugs as per the result of in vitro drug susceptibility testing (DST). We aimed to establish a standardized DST procedure based on quantitative determination of drug resistance and compared the results with those of genotypes associated with drug resistance. The protocol, based on MGIT 960 and the TB eXiST software, was evaluated in nine European reference laboratories. Resistance detection at a screening drug concentration was followed by determination of resistance levels and estimation of the resistance proportion. Mutations in 14 gene regions were investigated using established techniques. A total of 139 Mycobacterium tuberculosis isolates from patients with MDR-TB and resistance beyond MDR-TB were tested for 13 antituberculous drugs: isoniazid, rifampicin, rifabutin, ethambutol, pyrazinamide, streptomycin, para-aminosalicylic acid, ethionamide, amikacin, capreomycin, ofloxacin, moxifloxacin and linezolid. Concordance between phenotypic and genotypic resistance was >80%, except for ethambutol. Time to results was short (median 10 days). High-level resistance, which precludes the therapeutic use of an antituberculous drug, was observed in 49% of the isolates. The finding of a low or intermediate resistance level in 16% and 35% of the isolates, respectively, may help in designing an efficient personalized regimen for the treatment of MDR-TB patients. The automated DST procedure permits accurate and rapid quantitative resistance profiling of first- and second-line antituberculous drugs. Prospective validation is warranted to determine the impact on patient care. © The Author 2014. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  18. Misleading biochemical laboratory test results

    PubMed Central

    Nanji, Amin A.

    1984-01-01

    This article reviews the general and specific factors that interfere with the performance of common biochemical laboratory tests and the interpretation of their results. The clinical status of the patient, drug interactions, and in-vivo and in-vitro biochemical interactions and changes may alter the results obtained from biochemical analysis of blood constituents. Failure to recognize invalid laboratory test results may lead to injudicious and dangerous management of patients. PMID:6375845

  19. Testing natural selection vs. genetic drift in phenotypic evolution using quantitative trait locus data.

    PubMed Central

    Orr, H A

    1998-01-01

    Evolutionary biologists have long sought a way to determine whether a phenotypic difference between two taxa was caused by natural selection or random genetic drift. Here I argue that data from quantitative trait locus (QTL) analyses can be used to test the null hypothesis of neutral phenotypic evolution. I propose a sign test that compares the observed number of plus and minus alleles in the "high line" with that expected under neutrality, conditioning on the known phenotypic difference between the taxa. Rejection of the null hypothesis implies a role for directional natural selection. This test is applicable to any character in any organism in which QTL analysis can be performed. PMID:9691061

  20. 49 CFR 236.110 - Results of tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Results of tests. 236.110 Section 236.110...: All Systems Inspections and Tests; All Systems § 236.110 Results of tests. (a) Results of tests made... records must show the name of the railroad, place and date, equipment tested, results of tests, repairs...

  1. 49 CFR 236.110 - Results of tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Results of tests. 236.110 Section 236.110...: All Systems Inspections and Tests; All Systems § 236.110 Results of tests. (a) Results of tests made... records must show the name of the railroad, place and date, equipment tested, results of tests, repairs...

  2. 49 CFR 236.110 - Results of tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Results of tests. 236.110 Section 236.110...: All Systems Inspections and Tests; All Systems § 236.110 Results of tests. (a) Results of tests made... records must show the name of the railroad, place and date, equipment tested, results of tests, repairs...

  3. 49 CFR 236.110 - Results of tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Results of tests. 236.110 Section 236.110...: All Systems Inspections and Tests; All Systems § 236.110 Results of tests. (a) Results of tests made... records must show the name of the railroad, place and date, equipment tested, results of tests, repairs...

  4. 49 CFR 236.110 - Results of tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Results of tests. 236.110 Section 236.110...: All Systems Inspections and Tests; All Systems § 236.110 Results of tests. (a) Results of tests made... records must show the name of the railroad, place and date, equipment tested, results of tests, repairs...

  5. 40 CFR 799.12 - Test results.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 32 2014-07-01 2014-07-01 false Test results. 799.12 Section 799.12...) IDENTIFICATION OF SPECIFIC CHEMICAL SUBSTANCE AND MIXTURE TESTING REQUIREMENTS General Provisions § 799.12 Test results. Except as set forth in specific chemical test rules in subpart B of this part, a positive or...

  6. 40 CFR 799.12 - Test results.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 32 2011-07-01 2011-07-01 false Test results. 799.12 Section 799.12...) IDENTIFICATION OF SPECIFIC CHEMICAL SUBSTANCE AND MIXTURE TESTING REQUIREMENTS General Provisions § 799.12 Test results. Except as set forth in specific chemical test rules in subpart B of this part, a positive or...

  7. Validating a dance-specific screening test for balance: preliminary results from multisite testing.

    PubMed

    Batson, Glenna

    2010-09-01

    Few dance-specific screening tools adequately capture balance. The aim of this study was to administer and modify the Star Excursion Balance Test (oSEBT) to examine its utility as a balance screen for dancers. The oSEBT involves standing on one leg while lightly targeting with the opposite foot to the farthest distance along eight spokes of a star-shaped grid. This task simulates dance in the spatial pattern and movement quality of the gesturing limb. The oSEBT was validated for distance on athletes with history of ankle sprain. Thirty-three dancers (age 20.1 +/- 1.4 yrs) participated from two contemporary dance conservatories (UK and US), with or without a history of lower extremity injury. Dancers were verbally instructed (without physical demonstration) to execute the oSEBT and four modifications (mSEBT): timed (speed), timed with cognitive interference (answering questions aloud), and sensory disadvantaging (foam mat). Stepping strategies were tracked and performance strategies video-recorded. Unlike the oSEBT results, distances reached were not significant statistically (p = 0.05) or descriptively (i.e., shorter) for either group. Performance styles varied widely, despite sample homogeneity and instructions to control for strategy. Descriptive analysis of mSEBT showed an increased number of near-falls and decreased timing on the injured limb. Dancers appeared to employ variable strategies to keep balance during this test. Quantitative analysis is warranted to define balance strategies for further validation of SEBT modifications to determine its utility as a balance screening tool.

  8. Thermal quantitative sensory testing to assess the sensory effects of three local anesthetic solutions in a randomized trial of interscalene blockade for shoulder surgery.

    PubMed

    Sermeus, Luc A; Hans, Guy H; Schepens, Tom; Bosserez, Nathalie M-L; Breebaart, Margaretha B; Smitz, Carine J; Vercauteren, Marcel P

    2016-01-01

    This study investigated whether quantitative sensory testing (QST) with thermal stimulations can quantitatively measure the characteristics of an ultrasound-guided interscalene brachial plexus block (US-ISB). This was a prospective randomized trial in patients scheduled for arthroscopic shoulder surgery under general anesthesia and US-ISB. Participants and observers were blinded for the study. We assigned the study participants to one of three groups: 0.5% levobupivacaine 15 mL, 0.5% levobupivacaine 15 mL with 1:200,000 epinephrine, and 0.75% ropivacaine 15 mL. We performed thermal QST within dermatomes C4, C5, C6, and C7 before infiltration and 30 min, six hours, ten hours, and 24 hr after performing the US-ISB. In addition, we used QST, a semi-objective quantitative testing method, to measure the onset, intensity, duration, extent, and functional recovery of the sensory block. We also measured detection thresholds for cold/warm sensations and cold/heat pain. Detection thresholds for all thermal sensations within the ipsilateral C4, C5, C6, and C7 dermatomes increased rapidly (indicating the development of a hypoesthetic state) and reached a steady state after 30 min. This lasted for approximately ten hours and returned to normal detection thresholds by 24 hr. There were no differences detected between the three groups at 24 hr when we compared warm sensation thresholds on one dermatome. Visual inspection of the pooled results per dermatome suggests the ability of QST to detect clinically relevant differences in block intensity per dermatome. Quantitative sensory testing can be useful as a method for detecting the presence and characteristics of regional anesthesia-induced sensory block and may be used for the evaluation of clinical protocols. The three local anesthetic solutions exhibited a similar anesthetic effect. The results support the use of QST to assess block characteristics quantitatively under clinical research conditions. This trial was registered at

  9. Quantitative methods in assessment of neurologic function.

    PubMed

    Potvin, A R; Tourtellotte, W W; Syndulko, K; Potvin, J

    1981-01-01

    Traditionally, neurologists have emphasized qualitative techniques for assessing results of clinical trials. However, in recent years qualitative evaluations have been increasingly augmented by quantitative tests for measuring neurologic functions pertaining to mental state, strength, steadiness, reactions, speed, coordination, sensation, fatigue, gait, station, and simulated activities of daily living. Quantitative tests have long been used by psychologists for evaluating asymptomatic function, assessing human information processing, and predicting proficiency in skilled tasks; however, their methodology has never been directly assessed for validity in a clinical environment. In this report, relevant contributions from the literature on asymptomatic human performance and that on clinical quantitative neurologic function are reviewed and assessed. While emphasis is focused on tests appropriate for evaluating clinical neurologic trials, evaluations of tests for reproducibility, reliability, validity, and examiner training procedures, and for effects of motivation, learning, handedness, age, and sex are also reported and interpreted. Examples of statistical strategies for data analysis, scoring systems, data reduction methods, and data display concepts are presented. Although investigative work still remains to be done, it appears that carefully selected and evaluated tests of sensory and motor function should be an essential factor for evaluating clinical trials in an objective manner.

  10. Development of a relational database to capture and merge clinical history with the quantitative results of radionuclide renography.

    PubMed

    Folks, Russell D; Savir-Baruch, Bital; Garcia, Ernest V; Verdes, Liudmila; Taylor, Andrew T

    2012-12-01

    Our objective was to design and implement a clinical history database capable of linking to our database of quantitative results from (99m)Tc-mercaptoacetyltriglycine (MAG3) renal scans and export a data summary for physicians or our software decision support system. For database development, we used a commercial program. Additional software was developed in Interactive Data Language. MAG3 studies were processed using an in-house enhancement of a commercial program. The relational database has 3 parts: a list of all renal scans (the RENAL database), a set of patients with quantitative processing results (the Q2 database), and a subset of patients from Q2 containing clinical data manually transcribed from the hospital information system (the CLINICAL database). To test interobserver variability, a second physician transcriber reviewed 50 randomly selected patients in the hospital information system and tabulated 2 clinical data items: hydronephrosis and presence of a current stent. The CLINICAL database was developed in stages and contains 342 fields comprising demographic information, clinical history, and findings from up to 11 radiologic procedures. A scripted algorithm is used to reliably match records present in both Q2 and CLINICAL. An Interactive Data Language program then combines data from the 2 databases into an XML (extensible markup language) file for use by the decision support system. A text file is constructed and saved for review by physicians. RENAL contains 2,222 records, Q2 contains 456 records, and CLINICAL contains 152 records. The interobserver variability testing found a 95% match between the 2 observers for presence or absence of ureteral stent (κ = 0.52), a 75% match for hydronephrosis based on narrative summaries of hospitalizations and clinical visits (κ = 0.41), and a 92% match for hydronephrosis based on the imaging report (κ = 0.84). We have developed a relational database system to integrate the quantitative results of MAG3 image

  11. Airframe Noise Results from the QTD II Flight Test Program

    NASA Technical Reports Server (NTRS)

    Elkoby, Ronen; Brusniak, Leon; Stoker, Robert W.; Khorrami, Mehdi R.; Abeysinghe, Amal; Moe, Jefferey W.

    2007-01-01

    With continued growth in air travel, sensitivity to community noise intensifies and materializes in the form of increased monitoring, regulations, and restrictions. Accordingly, realization of quieter aircraft is imperative, albeit only achievable with reduction of both engine and airframe components of total aircraft noise. Model-scale airframe noise testing has aided in this pursuit; however, the results are somewhat limited due to lack of fidelity of model hardware, particularly in simulating full-scale landing gear. Moreover, simulation of true in-flight conditions is non-trivial if not infeasible. This paper reports on an investigation of full-scale landing gear noise measured as part of the 2005 Quiet Technology Demonstrator 2 (QTD2) flight test program. Conventional Boeing 777-300ER main landing gear were tested, along with two noise reduction concepts, namely a toboggan fairing and gear alignment with the local flow, both of which were down-selected from various other noise reduction devices evaluated in model-scale testing at Virginia Tech. The full-scale toboggan fairings were designed by Goodrich Aerostructures as add-on devices allowing for complete retraction of the main gear. The baseline-conventional gear, faired gear, and aligned gear were all evaluated with the high-lift system in the retracted position and deployed at various flap settings, all at engine idle power setting. Measurements were taken with flyover community noise microphones and a large aperture acoustic phased array, yielding far-field spectra, and localized sources (beamform maps). The results were utilized to evaluate qualitatively and quantitatively the merit of each noise reduction concept. Complete similarity between model-scale and full-scale noise reduction levels was not found and requires further investigation. Far-field spectra exhibited no noise reduction for both concepts across all angles and frequencies. Phased array beamform maps show inconclusive evidence of noise

  12. [Roaming through methodology. XXXII. False test results].

    PubMed

    van der Weijden, T; van den Akker, M

    2001-05-12

    The number of requests for diagnostic tests is rising. This leads to a higher chance of false test results. The false-negative proportion of a test is the proportion of negative test results among the diseased subjects. The false-positive proportion is the proportion of positive test results among the healthy subjects. The calculation of the false-positive proportion is often incorrect. For example, instead of 1 minus the specificity it is calculated as 1 minus the positive predictive value. This can lead to incorrect decision-making with respect to the application of the test. Physicians must apply diagnostic tests in such a way that the risk of false test results is minimal. The patient should be aware that a perfectly conclusive diagnostic test is rare in medical practice, and should more often be informed of the implications of false-positive and false-negative test results.

  13. Assessment of the clinical relevance of quantitative sensory testing with Von Frey monofilaments in patients with allodynia and neuropathic pain. A pilot study.

    PubMed

    Keizer, D; van Wijhe, M; Post, W J; Uges, D R A; Wierda, J M K H

    2007-08-01

    Allodynia is a common and disabling symptom in many patients with neuropathic pain. Whereas quantification of pain mostly depends on subjective pain reports, allodynia can also be measured objectively with quantitative sensory testing. In this pilot study, we investigated the clinical relevance of quantitative sensory testing with Von Frey monofilaments in patients with allodynia as a consequence of a neuropathic pain syndrome, by means of correlating subjective pain scores with pain thresholds obtained with quantitative sensory testing. During a 4-week trial, we administered a cannabis extract to 17 patients with allodynia. We quantified the severity of the allodynia with Von Frey monofilaments before, during and after the patients finished the trial. We also asked the patients to rate their pain on a numeric rating scale at these three moments. We found that most of the effect of the cannabis occurred in the last 2 weeks of the trial. In this phase, we observed that the pain thresholds, as measured with Von Frey monofilaments, were inversely correlated with a decrease of the perceived pain intensity. These preliminary findings indicate clinical relevance of quantitative sensory testing with Von Frey monofilaments in the quantification of allodynia in patients with neuropathic pain, although confirmation of our data is still required in further studies to position this method of quantitative sensory testing as a valuable tool, for example, in the evaluation of therapeutic interventions for neuropathic pain.

  14. Testing process predictions of models of risky choice: a quantitative model comparison approach

    PubMed Central

    Pachur, Thorsten; Hertwig, Ralph; Gigerenzer, Gerd; Brandstätter, Eduard

    2013-01-01

    This article presents a quantitative model comparison contrasting the process predictions of two prominent views on risky choice. One view assumes a trade-off between probabilities and outcomes (or non-linear functions thereof) and the separate evaluation of risky options (expectation models). Another view assumes that risky choice is based on comparative evaluation, limited search, aspiration levels, and the forgoing of trade-offs (heuristic models). We derived quantitative process predictions for a generic expectation model and for a specific heuristic model, namely the priority heuristic (Brandstätter et al., 2006), and tested them in two experiments. The focus was on two key features of the cognitive process: acquisition frequencies (i.e., how frequently individual reasons are looked up) and direction of search (i.e., gamble-wise vs. reason-wise). In Experiment 1, the priority heuristic predicted direction of search better than the expectation model (although neither model predicted the acquisition process perfectly); acquisition frequencies, however, were inconsistent with both models. Additional analyses revealed that these frequencies were primarily a function of what Rubinstein (1988) called “similarity.” In Experiment 2, the quantitative model comparison approach showed that people seemed to rely more on the priority heuristic in difficult problems, but to make more trade-offs in easy problems. This finding suggests that risky choice may be based on a mental toolbox of strategies. PMID:24151472

  15. Development, application, and results of routine monitoring of Marek's disease virus in broiler house dust using real-time quantitative PCR.

    PubMed

    Walkden-Brown, Stephen W; Islam, A F Aminul; Groves, Peter J; Rubite, Ambrosio; Sharpe, Sue M; Burgess, Susan K

    2013-06-01

    Results are presented from four studies between 2002 and 2011 into the feasibility of routinely monitoring Marek's disease virus serotype 1 (MDV-1) in broiler house dust using real-time quantitative PCR (qPCR) measurement. Study 1 on two farms showed that detection of MDV-1 occurred earlier on average in dust samples tested using qPCR than standard PCR and in spleen samples from five birds per shed assayed for MDV-1 by qPCR or standard PCR. DNA quality following extraction from dust had no effect on detection of MDV-1. Study 2 demonstrated that herpesvirus of turkeys (HVT) and MDV serotype 2 (MDV-2) in addition to MDV-1 could be readily amplified from commercial farm dust samples, often in mixtures. MDV-2 was detected in 11 of 20 samples despite the absence of vaccination with this serotype. Study 3 investigated the reproducibility and sensitivity of the qPCR test and the presence of inhibitors in the samples. Samples extracted and amplified in triplicate showed a high level of reproducibility except at very low levels of virus near the limit of detection. Mixing of samples prior to extraction provided results consistent with the proportions in the mixture. Tests for inhibition showed that if the template contained DNA in the range 0.5-20 ng/microl no inhibition of the reaction was detectable. The sensitivity of the tests in terms of viral copy number (VCN) per milligram of dust was calculated to be in the range 24-600 VCN/mg for MDV-1, 48-1200 VCN/mg for MDV-2, and 182-4560 VCN/mg for HVT. In study 4 the results of 1976 commercial tests carried out for one company were analyzed. Overall 23.1% of samples were positive for MDV-1, 26.1% in unvaccinated and 16.4% in vaccinated chickens. There was marked regional and temporal variation in the proportion of positive samples and the MDV-1 load. The tests were useful in formulating Marek's disease vaccination strategies. The number of samples submitted has increased recently, as has the incidence of positive samples

  16. Performance of a semi-quantitative whole blood test for human heart-type fatty acid-binding protein (H-FABP).

    PubMed

    Hiura, Masahito; Nakajima, Osamu; Mori, Toshizumi; Kitano, Katsuya

    2005-10-01

    We evaluated the accuracy of visually reading the whole blood Rapicheck H-FABP panel test using the quantitative plasma H-FABP concentration as the reference. Consecutive patients with chest pain (n = 237) who were suspected of having acute myocardial infarction were recruited. The appearance of an evident test line within 5 min was given a grade of +3 (strongly positive), appearance within 15 min +2 (moderately positive) and the appearance of a weak test line within 15 min +1 (weakly positive). The concordance rates were 91.8% for positive, 70.1% for negative and 80.2% for overall. Plasma H-FABP concentrations were above the cut-off value for 9.2% of negative (0) results. Fifty percent of weakly positive (+1) and 25.0% of moderately positive (+2) results had H-FABP concentrations lower than the cut-off value. All of the strongly positive (+3) were above the cut-off value. These results suggested that the false-positive and false-negative results of Rapicheck H-FABP were caused by over or underestimation in visual reading when the plasma H-FABP concentration was near the cut-off concentration. Low accuracy of visual reading of Rapicheck H-FABP was due to poor estimation by manual reading around the cut-off value.

  17. The Impact of Acquisition Dose on Quantitative Breast Density Estimation with Digital Mammography: Results from ACRIN PA 4006.

    PubMed

    Chen, Lin; Ray, Shonket; Keller, Brad M; Pertuz, Said; McDonald, Elizabeth S; Conant, Emily F; Kontos, Despina

    2016-09-01

    Purpose To investigate the impact of radiation dose on breast density estimation in digital mammography. Materials and Methods With institutional review board approval and Health Insurance Portability and Accountability Act compliance under waiver of consent, a cohort of women from the American College of Radiology Imaging Network Pennsylvania 4006 trial was retrospectively analyzed. All patients underwent breast screening with a combination of dose protocols, including standard full-field digital mammography, low-dose digital mammography, and digital breast tomosynthesis. A total of 5832 images from 486 women were analyzed with previously validated, fully automated software for quantitative estimation of density. Clinical Breast Imaging Reporting and Data System (BI-RADS) density assessment results were also available from the trial reports. The influence of image acquisition radiation dose on quantitative breast density estimation was investigated with analysis of variance and linear regression. Pairwise comparisons of density estimations at different dose levels were performed with Student t test. Agreement of estimation was evaluated with quartile-weighted Cohen kappa values and Bland-Altman limits of agreement. Results Radiation dose of image acquisition did not significantly affect quantitative density measurements (analysis of variance, P = .37 to P = .75), with percent density demonstrating a high overall correlation between protocols (r = 0.88-0.95; weighted κ = 0.83-0.90). However, differences in breast percent density (1.04% and 3.84%, P < .05) were observed within high BI-RADS density categories, although they were significantly correlated across the different acquisition dose levels (r = 0.76-0.92, P < .05). Conclusion Precision and reproducibility of automated breast density measurements with digital mammography are not substantially affected by variations in radiation dose; thus, the use of low-dose techniques for the purpose of density estimation

  18. The Impact of Acquisition Dose on Quantitative Breast Density Estimation with Digital Mammography: Results from ACRIN PA 4006

    PubMed Central

    Chen, Lin; Ray, Shonket; Keller, Brad M.; Pertuz, Said; McDonald, Elizabeth S.; Conant, Emily F.

    2016-01-01

    Purpose To investigate the impact of radiation dose on breast density estimation in digital mammography. Materials and Methods With institutional review board approval and Health Insurance Portability and Accountability Act compliance under waiver of consent, a cohort of women from the American College of Radiology Imaging Network Pennsylvania 4006 trial was retrospectively analyzed. All patients underwent breast screening with a combination of dose protocols, including standard full-field digital mammography, low-dose digital mammography, and digital breast tomosynthesis. A total of 5832 images from 486 women were analyzed with previously validated, fully automated software for quantitative estimation of density. Clinical Breast Imaging Reporting and Data System (BI-RADS) density assessment results were also available from the trial reports. The influence of image acquisition radiation dose on quantitative breast density estimation was investigated with analysis of variance and linear regression. Pairwise comparisons of density estimations at different dose levels were performed with Student t test. Agreement of estimation was evaluated with quartile-weighted Cohen kappa values and Bland-Altman limits of agreement. Results Radiation dose of image acquisition did not significantly affect quantitative density measurements (analysis of variance, P = .37 to P = .75), with percent density demonstrating a high overall correlation between protocols (r = 0.88–0.95; weighted κ = 0.83–0.90). However, differences in breast percent density (1.04% and 3.84%, P < .05) were observed within high BI-RADS density categories, although they were significantly correlated across the different acquisition dose levels (r = 0.76–0.92, P < .05). Conclusion Precision and reproducibility of automated breast density measurements with digital mammography are not substantially affected by variations in radiation dose; thus, the use of low-dose techniques for the purpose of density

  19. Overcoming pain thresholds with multilevel models-an example using quantitative sensory testing (QST) data.

    PubMed

    Hirschfeld, Gerrit; Blankenburg, Markus R; Süß, Moritz; Zernikow, Boris

    2015-01-01

    The assessment of somatosensory function is a cornerstone of research and clinical practice in neurology. Recent initiatives have developed novel protocols for quantitative sensory testing (QST). Application of these methods led to intriguing findings, such as the presence lower pain-thresholds in healthy children compared to healthy adolescents. In this article, we (re-) introduce the basic concepts of signal detection theory (SDT) as a method to investigate such differences in somatosensory function in detail. SDT describes participants' responses according to two parameters, sensitivity and response-bias. Sensitivity refers to individuals' ability to discriminate between painful and non-painful stimulations. Response-bias refers to individuals' criterion for giving a "painful" response. We describe how multilevel models can be used to estimate these parameters and to overcome central critiques of these methods. To provide an example we apply these methods to data from the mechanical pain sensitivity test of the QST protocol. The results show that adolescents are more sensitive to mechanical pain and contradict the idea that younger children simply use more lenient criteria to report pain. Overall, we hope that the wider use of multilevel modeling to describe somatosensory functioning may advance neurology research and practice.

  20. Analytical results of a long-term aquifer test conducted near the Rio Grande, Albuquerque, New Mexico, with a section on piezometric-extensometric test results

    USGS Publications Warehouse

    Thorn, Conde R.; Heywood, Charles E.

    2001-01-01

    The City of Albuquerque, New Mexico, is interested in gaining a better understanding, both quantitative and qualitative, of the aquifer system in and around Albuquerque. Currently (2000), the City of Albuquerque and surrounding municipalities are completely dependent on ground-water reserves for their municipal water supply. This report presents the results of a long-term aquifer test conducted near the Rio Grande in Albuquerque. The long-term aquifer test was conducted during the winter of 1994-95. The City of Albuquerque Griegos 1 water production well was pumped continuously for 54 days at an average pumping rate of 2,331 gallons per minute. During the 54-day pumping and a 30-day recovery period, water levels were recorded in a monitoring network that consisted of 3 production wells and 19 piezometers located at nine sites. These wells and piezometers were screened in river alluvium and (or) the upper and middle parts of the Santa Fe Group aquifer system. In addition to the measurement of water levels, aquifer-system compaction was monitored during the aquifer test by an extensometer. Well-bore video and flowmeter surveys were conducted in the Griegos 1 water production well at the end of the recovery period to identify the location of primary water- producing zones along the screened interval. Analytical results from the aquifer test presented in this report are based on the methods used to analyze a leaky confined aquifer system and were performed using the computer software package AQTESOLV. Estimated transmissivities for the Griegos 1 and 4 water production wells ranged from 10,570 to 24,810 feet squared per day; the storage coefficient for the Griegos 4 well was 0.0025. A transmissivity of 13,540 feet squared per day and a storage coefficient of 0.0011 were estimated from the data collected from a piezometer completed in the production interval of the Griegos 1 well.

  1. Abnormal Cervical Cancer Screening Test Results

    MedlinePlus

    ... FAQ187 GYNECOLOGIC PROBLEMS Abnormal Cervical Cancer Screening Test Results • What is cervical cancer screening? • What causes abnormal cervical cancer screening test results? • What is the difference between the terms cervical ...

  2. Divisional role of quantitative HER2 testing in breast cancer.

    PubMed

    Yamamoto-Ibusuki, Mutsuko; Yamamoto, Yutaka; Fu, Peifen; Yamamoto, Satoko; Fujiwara, Saori; Honda, Yumi; Iyama, Ken-ichi; Iwase, Hirotaka

    2015-03-01

    Human epidermal growth factor receptor 2 (HER2) is amplified in human breast cancers in which therapy targeted to HER2 significantly improves patient outcome. We re-visited the use of real-time quantitative polymerase chain reaction (qPCR)-based assays using formalin-fixed paraffin-embedded (FFPE) tissues as alternative methods and investigated their particular clinical relevance. DNA and RNA were isolated from FFPE specimens and HER2 status was assessed by qPCR in 249 consecutive patients with primary breast cancer. Concordance with results forg immunohistochemistry (IHC) and in situ hybridization (ISH), clinical characteristics and survival was assessed. HER2 gene copy number had a stronger correlation with clinicopathological characteristics and excellent concordance with IHC/ISH results (Sensitivity: 96.7 %; concordance: 99.2 %). HER2 gene expression showed inadequate sensitivity, rendering it unsuitable to determine HER2 status (Sensitivity: 46.7 %; concordance: 92.1 %), but lower HER2 gene expression, leading to the classification of many cases as "false negative", contributed to a prediction of better prognosis within the HER2-amplified subpopulation. Quantitative HER2 assessments are suggested to have evolved their accuracy in this decade, which can be a potential alternative for HER2 diagnosis in line with the in situ method, while HER2 gene expression levels could provide additional information regarding prognosis or therapeutic strategy within a HER2-amplified subpopulation.

  3. Neurological Assessment Using a Quantitative Sensory Test in Patients with Chronic Unilateral Orofacial Pain.

    PubMed

    Salame, Talal H; Blinkhorn, Antony; Karami, Zahra

    2018-01-01

    Quantitative Sensory Testing (QST) has been used in clinical and experimental settings to establish sensory assessment for different types of pains, and may be a useful tool for the assessment of orofacial pain, but this premise needs to be tested. The aim of the study was to evaluate responses to thermal stimuli between painful and non-painful facial sites in subjects with orofacial pain using QST. A total of 60 participants (5o females: 28-83 years; 10 males: 44-81 years) with unilateral orofacial pain were recruited from the Orofacial Pain Clinic at the Pain Management and Research Centre, Royal North Shore Hospital, Sydney, Australia. The study followed the methods of limits of the German Research Network testing four modalities of thermal thresholds, the Warm Sensation, the Cold Sensation, the Heat Pain and the Cold Pain using a TSA-II Neurosensory Analyser. The results were compared to the results from the unaffected side of the same patient on the same area and a single t test statistical analysis was performed, where a p value of less than 0.05 was considered significant. The Mean Difference for Cold Sensation between the pain side and the non-pain side was 0.48 °C ± 1.5 (t= 2.466, p=0.017), 0.68 °C ± 2.04 for Warm Sensation (t= -2.573, p= 0.013), 2.56 °C ± 2.74 for Cold Pain (t= 7.238, p<0.001) and -1.21 °C ± 2.59 for Hot Pain (t= -3.639, p=0.001). The study showed that QST methods using thermal stimuli could be used to evaluate sensory dysfunction in orofacial pain patients using the specific parameters of cool and warm sensation, and cold and hot pain.

  4. Effects of fecal sampling on preanalytical and analytical phases in quantitative fecal immunochemical tests for hemoglobin.

    PubMed

    Rapi, Stefano; Berardi, Margherita; Cellai, Filippo; Ciattini, Samuele; Chelazzi, Laura; Ognibene, Agostino; Rubeca, Tiziana

    2017-07-24

    Information on preanalytical variability is mandatory to bring laboratories up to ISO 15189 requirements. Fecal sampling is greatly affected by lack of harmonization in laboratory medicine. The aims of this study were to obtain information on the devices used for fecal sampling and to explore the effect of different amounts of feces on the results from the fecal immunochemical test for hemoglobin (FIT-Hb). Four commercial sample collection devices for quantitative FIT-Hb measurements were investigated. The volume of interest (VOI) of the probes was measured from diameter and geometry. Quantitative measurements of the mass of feces were carried out by gravimetry. The effects of an increased amount of feces on the analytical environment were investigated measuring the Hb values with a single analytical method. VOI was 8.22, 7.1 and 9.44 mm3 for probes that collected a target of 10 mg of feces, and 3.08 mm3 for one probe that targeted 2 mg of feces. The ratio between recovered and target amounts of devices ranged from 56% to 121%. Different changes in the measured Hb values were observed, in adding increasing amounts of feces in commercial buffers. The amounts of collected materials are related to the design of probes. Three out 4 manufacturers declare the same target amount using different sampling volumes and obtaining different amounts of collected materials. The introduction of a standard probes to reduce preanalytical variability could be an useful step for fecal test harmonization and to fulfill the ISO 15189 requirements.

  5. Quantitative sensory testing of neuropathic pain patients: potential mechanistic and therapeutic implications.

    PubMed

    Pfau, Doreen B; Geber, Christian; Birklein, Frank; Treede, Rolf-Detlef

    2012-06-01

    Quantitative sensory testing (QST) is a widely accepted tool to investigate somatosensory changes in pain patients. Many different protocols have been developed in clinical pain research within recent years. In this review, we provide an overview of QST and tested neuroanatomical pathways, including peripheral and central structures. Based on research studies using animal and human surrogate models of neuropathic pain, possible underlying mechanisms of chronic pain are discussed. Clinically, QST may be useful for 1) the identification of subgroups of patients with different underlying pain mechanisms; 2) prediction of therapeutic outcomes; and 3) quantification of therapeutic interventions in pain therapy. Combined with sensory mapping, QST may provide useful information on the site of neural damage and on mechanisms of positive and negative somatosensory abnormalities. The use of QST in individual patients for diagnostic purposes leading to individualized therapy is an interesting concept, but needs further validation.

  6. Performance of a quantitative fecal immunochemical test in a colorectal cancer screening pilot program: a prospective cohort study.

    PubMed

    Telford, Jennifer; Gentile, Laura; Gondara, Lovedeep; McGahan, Colleen; Coldman, Andrew

    2016-01-01

    British Columbia undertook a colorectal cancer screening pilot program in 3 communities. Our objective was to assess the performance of 2-specimen fecal immunochemical testing in the detection of colorectal neoplasms in this population-based screening program. A prospective cohort of asymptomatic, average-risk people aged 50 to 74 years completed 2 quantitative fecal immunochemical tests every 2 years, with follow-up colonoscopy if the result of either test was positive. Participant demographics, fecal immunochemical test results, colonoscopy quality indicators and pathology results were recorded. Non-screen-detected colorectal cancer that developed in program participants was identified through review of data from the BC Cancer Registry. A total of 16 234 people completed a first round of fecal immunochemical testing, with a positivity rate of 8.6%; 5378 (86.0% of eligible participants) completed a second round before the end of the pilot program, with a positivity rate of 6.7%. Of the 1756 who had a positive test result, 1555 (88.6%) underwent colonoscopy. The detection rate of colorectal cancer was 3.5 per 1000 participants. The positive predictive value of the fecal immunochemical test was 4.9% (95% confidence interval [CI] 3.8%-6.0%) for colorectal cancer, 35.0% (95% CI 32.5%-37.2%) for high-risk polyps and 62.0% (95% CI 59.6%-64.4%) for all neoplasms. The number needed to screen was 283 to detect 1 cancer, 40 to detect 1 high-risk polyp and 22 to detect any neoplasm. Screening every 2 years with a 2-specimen fecal immunochemical test surpassed the current benchmark for colorectal cancer detection in population-based screening. This study has implications for other jurisdictions planning colorectal cancer screening programs.

  7. Validation and Estimation of Additive Genetic Variation Associated with DNA Tests for Quantitative Beef Cattle Traits

    USDA-ARS?s Scientific Manuscript database

    The U.S. National Beef Cattle Evaluation Consortium (NBCEC) has been involved in the validation of commercial DNA tests for quantitative beef quality traits since their first appearance on the U.S. market in the early 2000s. The NBCEC Advisory Council initially requested that the NBCEC set up a syst...

  8. Does contraceptive treatment in wildlife result in side effects? A review of quantitative and anecdotal evidence.

    PubMed

    Gray, Meeghan E; Cameron, Elissa Z

    2010-01-01

    The efficacy of contraceptive treatments has been extensively tested, and several formulations are effective at reducing fertility in a range of species. However, these formulations should minimally impact the behavior of individuals and populations before a contraceptive is used for population manipulation, but these effects have received less attention. Potential side effects have been identified theoretically and we reviewed published studies that have investigated side effects on behavior and physiology of individuals or population-level effects, which provided mixed results. Physiological side effects were most prevalent. Most studies reported a lack of secondary effects, but were usually based on qualitative data or anecdotes. A meta-analysis on quantitative studies of side effects showed that secondary effects consistently occur across all categories and all contraceptive types. This contrasts with the qualitative studies, suggesting that anecdotal reports are insufficient to investigate secondary impacts of contraceptive treatment. We conclude that more research is needed to address fundamental questions about secondary effects of contraceptive treatment and experiments are fundamental to conclusions. In addition, researchers are missing a vital opportunity to use contraceptives as an experimental tool to test the influence of reproduction, sex and fertility on the behavior of wildlife species.

  9. Lithium cell test results

    NASA Technical Reports Server (NTRS)

    Bragg, B. J.

    1977-01-01

    Three lithium SO2 cells, two lithium CF cells, and a vinyl chloride cell, all with crimped seals, and all strictly experimental, were independently discharged on resistors. Three temperatures were used and several different storage temperatures. Discharge rate generally on the nominal discharges were 0.1 amp, 0.5 amp, and 1 amp. Tests results show that the crimp seals are inadequate, especially for the SO2 cells. Normal discharges present no hazards. All cells discharge to zero. The problem of lithium cell explosions, such as occurred during off-limits testing, is discussed.

  10. Comparative evaluation of two quantitative test methods for determining the efficacy of liquid sporicides and sterilants on a hard surface: a precollaborative study.

    PubMed

    Tomasino, Stephen F; Hamilton, Martin A

    2007-01-01

    Two quantitative carrier-based test methods for determining the efficacy of liquid sporicides and sterilants on a hard surface, the Standard Quantitative Carrier Test Method-ASTM E 2111-00 and an adaptation of a quantitative micro-method as reported by Sagripanti and Bonifacino, were compared in this study. The methods were selected based on their desirable characteristics (e.g., well-developed protocol, previous use with spores, fully quantitative, and use of readily available equipment) for testing liquid sporicides and sterilants on a hard surface. In this paper, the Sagripanti-Bonifacino procedure is referred to as the Three Step Method (TSM). AOAC Official Method 966.04 was included in this study as a reference method. Three laboratories participated in the evaluation. Three chemical treatments were tested: (1) 3000 ppm sodium hypochlorite with pH adjusted to 7.0, (2) a hydrogen peroxide/peroxyacetic acid product, and (3) 3000 ppm sodium hypochlorite with pH unadjusted (pH of approximately 10.0). A fourth treatment, 6000 ppm sodium hypochlorite solution with pH adjusted to 7.0, was included only for Method 966.04 as a positive control (high level of efficacy). The contact time was 10 min for all chemical treatments except the 6000 ppm sodium hypochlorite treatment which was tested at 30 min. Each chemical treatment was tested 3 times using each of the methods. Only 2 of the laboratories performed the AOAC method. Method performance was assessed by the within-laboratory variance, between-laboratory variance, and total variance associated with the log reduction (LR) estimates generated by each quantitative method. The quantitative methods performed similarly, and the LR values generated by each method were not statistically different for the 3 treatments evaluated. Based on feedback from the participating laboratories, compared to the TSM, ASTM E 2111-00 was more resource demanding and required more set-up time. The logistical and resource concerns identified

  11. Hybrid TE panel test results

    NASA Technical Reports Server (NTRS)

    Bifano, W. J.

    1972-01-01

    Test results are presented for a nine couple (3 x 3 array) thermoelectric panel of hybrid thermocouples. In the hybrid couple, a hollow cylinder of p-type Si-Ge is used to encapsulate a segmented PbTe/Si-Ge n-leg. The hybrid couple is predicted to offer a 10- to 15-percent improvement in performance relative to all Si-Ge couples. The efficiency, output power, and internal resistance of the panel as well as the resistances of the individual hybrid couples are presented as a function of test time covering a period of more than 2600 hours. Initial test results indicated hybrid couple performance consistent with design predictions. Extraneous resistance ranged from 20 to 25% of the hybrid couple thermoelectric resistance.

  12. Routine Clinical Quantitative Rest Stress Myocardial Perfusion for Managing Coronary Artery Disease: Clinical Relevance of Test-Retest Variability.

    PubMed

    Kitkungvan, Danai; Johnson, Nils P; Roby, Amanda E; Patel, Monika B; Kirkeeide, Richard; Gould, K Lance

    2017-05-01

    Positron emission tomography (PET) quantifies stress myocardial perfusion (in cc/min/g) and coronary flow reserve to guide noninvasively the management of coronary artery disease. This study determined their test-retest precision within minutes and daily biological variability essential for bounding clinical decision-making or risk stratification based on low flow ischemic thresholds or follow-up changes. Randomized trials of fractional flow reserve-guided percutaneous coronary interventions established an objective, quantitative, outcomes-driven standard of physiological stenosis severity. However, pressure-derived fractional flow reserve requires invasive coronary angiogram and was originally validated by comparison to noninvasive PET. The time course and test-retest precision of serial quantitative rest-rest and stress-stress global myocardial perfusion by PET within minutes and days apart in the same patient were compared in 120 volunteers undergoing serial 708 quantitative PET perfusion scans using rubidium 82 (Rb-82) and dipyridamole stress with a 2-dimensional PET-computed tomography scanner (GE DST 16) and University of Texas HeartSee software with our validated perfusion model. Test-retest methodological precision (coefficient of variance) for serial quantitative global myocardial perfusion minutes apart is ±10% (mean ΔSD at rest ±0.09, at stress ±0.23 cc/min/g) and for days apart is ±21% (mean ΔSD at rest ±0.2, at stress ±0.46 cc/min/g) reflecting added biological variability. Global myocardial perfusion at 8 min after 4-min dipyridamole infusion is 10% higher than at standard 4 min after dipyridamole. Test-retest methodological precision of global PET myocardial perfusion by serial rest or stress PET minutes apart is ±10%. Day-to-different-day biological plus methodological variability is ±21%, thereby establishing boundaries of variability on physiological severity to guide or follow coronary artery disease management. Maximum stress

  13. A new rapid quantitative test for fecal calprotectin predicts endoscopic activity in ulcerative colitis.

    PubMed

    Lobatón, Triana; Rodríguez-Moranta, Francisco; Lopez, Alicia; Sánchez, Elena; Rodríguez-Alonso, Lorena; Guardiola, Jordi

    2013-04-01

    Fecal calprotectin (FC) determined by the enzyme-linked immunosorbent assay (ELISA) test has been proposed as a promising biomarker of endoscopic activity in ulcerative colitis (UC). However, data on its accuracy in predicting endoscopic activity is scarce. Besides, FC determined by the quantitative-point-of-care test (FC-QPOCT) that provides rapid and individual results could optimize its use in clinical practice. The aims of our study were to evaluate the ability of FC to predict endoscopic activity according to the Mayo score in patients with UC when determined by FC-QPOCT and to compare it with the ELISA test (FC-ELISA). FC was determined simultaneously by FC-ELISA and FC-QPOCT in patients with UC undergoing colonoscopy. Clinical disease activity and endoscopy were assessed according to the Mayo score. Blood tests were taken to analyze serological biomarkers. A total of 146 colonoscopies were performed on 123 patients with UC. FC-QPOCT correlated more closely with the Mayo endoscopic subscore (Spearman's correlation coefficient rank r = 0.727, P < 0.001) than clinical activity (r = 0.636, P < 0.001), platelets (r = 0.381, P < 0.001), leucocytes (r = 0.300, P < 0.001), and C-reactive protein (r = 0.291, P = 0.002). The prediction of "endoscopic remission" (Mayo endoscopic subscore ≤1) with FC-QPOCT (280 µg/g) and FC-ELISA (250 µg/g) presented an area under the curve of 0.906 and 0.924, respectively. The interclass correlation index between both tests was 0.904 (95% confidence interval, 0.864-0.932; P < 0.001). FC determined by QPOCT was an accurate surrogate marker of "endoscopic remission" in UC and presented a good correlation with the FC-ELISA test.

  14. State Test Results Are Predictable

    ERIC Educational Resources Information Center

    Tienken, Christopher H.

    2014-01-01

    Out-of-school, community demographic and family-level variables have an important influence on student achievement as measured by large-scale standardized tests. Studies described here demonstrated that about half of the test score is accounted for by variables outside the control of teachers and school administrators. The results from these…

  15. Evaluation of sample stability for a quantitative faecal immunochemical test and comparison of two sample collection approaches.

    PubMed

    Mellen, Samantha; de Ferrars, Maria; Chapman, Claire; Bevan, Sarah; Turvill, James; Turnock, Daniel

    2018-01-01

    Background Faecal immunochemical testing is increasingly being used to triage symptomatic patients for suspected colorectal cancer. However, there are limited data on the effect of preanalytical factors on faecal haemoglobin when measured by faecal immunochemical testing. The aim of this work was to evaluate the stability of faecal haemoglobin in faeces and to compare two methods of faecal haemoglobin sampling for faecal immunochemical testing. Methods Six patients provided faeces for faecal haemoglobin measurement which were transferred into specialized collection devices at baseline and at 1, 2, 3 and 7 days after storage at either room temperature or 4°C. A total of 137 patients returned both faeces transferred into the specialized collection device and faeces in a standard collection pot. A quantitative immunoturbidometric method was used to measure faecal haemoglobin and results were compared categorically. Discrepant results were assessed against diagnosis. Results Faecal haemoglobin concentration declined rapidly within a day of storage at room temperature but results remained ≥10 μg Hb/g faeces in 5/6 patients after two days. A faecal haemoglobin result ≥10 μg Hb/g faeces was obtained in 4/6 patients after storage for seven days at 4°C. Results obtained when patients used specialized collection devices were significantly different from results obtained when faeces was transferred into the specialized collection device in the laboratory. Conclusion There is considerable heterogeneity in the sample stability of faecal haemoglobin; therefore, samples should be transferred rapidly into specialized collection devices to prevent false-negative results. Use of collection devices by patients can lead to false-positive results compared with their use in a laboratory.

  16. Quality control for quantitative PCR based on amplification compatibility test.

    PubMed

    Tichopad, Ales; Bar, Tzachi; Pecen, Ladislav; Kitchen, Robert R; Kubista, Mikael; Pfaffl, Michael W

    2010-04-01

    Quantitative qPCR is a routinely used method for the accurate quantification of nucleic acids. Yet it may generate erroneous results if the amplification process is obscured by inhibition or generation of aberrant side-products such as primer dimers. Several methods have been established to control for pre-processing performance that rely on the introduction of a co-amplified reference sequence, however there is currently no method to allow for reliable control of the amplification process without directly modifying the sample mix. Herein we present a statistical approach based on multivariate analysis of the amplification response data generated in real-time. The amplification trajectory in its most resolved and dynamic phase is fitted with a suitable model. Two parameters of this model, related to amplification efficiency, are then used for calculation of the Z-score statistics. Each studied sample is compared to a predefined reference set of reactions, typically calibration reactions. A probabilistic decision for each individual Z-score is then used to identify the majority of inhibited reactions in our experiments. We compare this approach to univariate methods using only the sample specific amplification efficiency as reporter of the compatibility. We demonstrate improved identification performance using the multivariate approach compared to the univariate approach. Finally we stress that the performance of the amplification compatibility test as a quality control procedure depends on the quality of the reference set. Copyright 2010 Elsevier Inc. All rights reserved.

  17. A novel gel based vehicle for the delivery of acetylcholine in quantitative sudomotor axon reflex testing.

    PubMed

    Sletten, David M; Kimpinski, Kurt; Weigand, Stephen D; Low, Phillip A

    2009-10-05

    This study describes a novel gel based vehicle for the delivery of acetylcholine (ACh) during quantitative sudomotor axon reflex testing (QSART). A dose and current response study were undertaken on 20 healthy control participants to characterize the efficiency of a gel based vehicle for the delivery of ACh. Values obtained for total sweat volume and latency to sweat onset with gel iontophoresis of ACh during QSART were comparable to previously published normative data using solution based vehicles. Patient discomfort, utilizing the gel based vehicle during the QSART procedure, was minimal. Improvement in iontophoresis using the gel formulation as a vehicle for ACh delivery has the potential to lower the voltage required to overcome skin resistance during QSART and may result in improved patient comfort during the procedure.

  18. Investigation of prefrontal cerebral hemodynamics during quantitative autonomic testing using NIRS (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Phillips, Zephaniah; Paik, Seung-Ho; Kim, Yoohwan; Kim, Byung-Jo; Choi, Youngwoon; Kim, Beop-Min

    2017-02-01

    In this work, we analyzed the clinical applicability of NIRS for use during Quantitative Autonomic Testing (QAT). QAT is a protocol consisting of deep breathing, Valsalva maneuver, and tilt table examination. It is used to diagnose a patient with disorders of the autonomic nervous system (ANS). Disorders of ANS includes orthostatic hyper/hypotension, vasovagal syncope, and postural orthostatic tachycardia syndrome. The results of QAT are typically analyzed with the use of blood pressure and heart rate data, however these metrics may be influenced by factors such as arrhythmia, making the data interpretation and diagnosis difficult for clinicians. We tested our custom built 108-channel NIRS probe on 26 elderly patients during the QAT protocol with various ANS disorders. We found that prefrontal cerebral oxygenation correlated well with blood pressure and heart rate changes for all three tasks, making it a clinically feasible tool for observing ANS functionality. During the Valsalva maneuver, we observed a longer delayed and lower amplitude response of cerebral oxygenation to the prefrontal area in orthostatic intolerant patients. During the tilt table examination, we saw a larger response in cerebral oxygenation and less equal transient cerebral oxygenation during tilt up and tilt down in tilt table examinations that were positive (unhealthy), compared to tilt table examinations that were negative (healthy). Overall, our study showcases NIRS as an enhanced tool for understanding ANS disorders.

  19. A quantitative comparison of corrective and perfective maintenance

    NASA Technical Reports Server (NTRS)

    Henry, Joel; Cain, James

    1994-01-01

    This paper presents a quantitative comparison of corrective and perfective software maintenance activities. The comparison utilizes basic data collected throughout the maintenance process. The data collected are extensive and allow the impact of both types of maintenance to be quantitatively evaluated and compared. Basic statistical techniques test relationships between and among process and product data. The results show interesting similarities and important differences in both process and product characteristics.

  20. Quantitative imaging test approval and biomarker qualification: interrelated but distinct activities.

    PubMed

    Buckler, Andrew J; Bresolin, Linda; Dunnick, N Reed; Sullivan, Daniel C; Aerts, Hugo J W L; Bendriem, Bernard; Bendtsen, Claus; Boellaard, Ronald; Boone, John M; Cole, Patricia E; Conklin, James J; Dorfman, Gary S; Douglas, Pamela S; Eidsaunet, Willy; Elsinger, Cathy; Frank, Richard A; Gatsonis, Constantine; Giger, Maryellen L; Gupta, Sandeep N; Gustafson, David; Hoekstra, Otto S; Jackson, Edward F; Karam, Lisa; Kelloff, Gary J; Kinahan, Paul E; McLennan, Geoffrey; Miller, Colin G; Mozley, P David; Muller, Keith E; Patt, Rick; Raunig, David; Rosen, Mark; Rupani, Haren; Schwartz, Lawrence H; Siegel, Barry A; Sorensen, A Gregory; Wahl, Richard L; Waterton, John C; Wolf, Walter; Zahlmann, Gudrun; Zimmerman, Brian

    2011-06-01

    Quantitative imaging biomarkers could speed the development of new treatments for unmet medical needs and improve routine clinical care. However, it is not clear how the various regulatory and nonregulatory (eg, reimbursement) processes (often referred to as pathways) relate, nor is it clear which data need to be collected to support these different pathways most efficiently, given the time- and cost-intensive nature of doing so. The purpose of this article is to describe current thinking regarding these pathways emerging from diverse stakeholders interested and active in the definition, validation, and qualification of quantitative imaging biomarkers and to propose processes to facilitate the development and use of quantitative imaging biomarkers. A flexible framework is described that may be adapted for each imaging application, providing mechanisms that can be used to develop, assess, and evaluate relevant biomarkers. From this framework, processes can be mapped that would be applicable to both imaging product development and to quantitative imaging biomarker development aimed at increasing the effectiveness and availability of quantitative imaging. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.10100800/-/DC1. RSNA, 2011

  1. Towards the automatization of the Foucault knife-edge quantitative test

    NASA Astrophysics Data System (ADS)

    Rodríguez, G.; Villa, J.; Martínez, G.; de la Rosa, I.; Ivanov, R.

    2017-08-01

    Given the increasing necessity of simple, economical and reliable methods and instruments for performing quality tests of optical surfaces such as mirrors and lenses, in the recent years we resumed the study of the long forgotten Foucault knife-edge test from the point of view of the physical optics, ultimately achieving a closed mathematical expression that directly relates the knife-edge position along the displacement paraxial axis with the observable irradiance pattern, which later allowed us to propose a quantitative methodology for estimating the wavefront error of an aspherical mirror with precision akin to interferometry. In this work, we present a further improved digital image processing algorithm in which the sigmoidal cost-function for calculating the transient slope-point of each associated intensity-illumination profile is replaced for a simplified version of it, thus making the whole process of estimating the wavefront gradient remarkably more stable and efficient, at the same time, the Fourier based algorithm employed for gradient integration has been replaced as well for a regularized quadratic cost-function that allows a considerably easier introduction of the region of interest (ROI) of the function, which solved by means of a linear gradient conjugate method largely increases the overall accuracy and efficiency of the algorithm. This revised approach of our methodology can be easily implemented and handled by most single-board microcontrollers in the market, hence enabling the implementation of a full-integrated automatized test apparatus, opening a realistic path for even the proposal of a stand-alone optical mirror analyzer prototype.

  2. Respiratory protection against Mycobacterium tuberculosis: quantitative fit test outcomes for five type N95 filtering-facepiece respirators.

    PubMed

    Lee, Kiyoung; Slavcev, Andrea; Nicas, Mark

    2004-01-01

    In preparing to fit test a large workforce, a respirator program manager needs to initially choose respirators that will fit the greatest proportion of employees and achieve the best fits. This article discusses our strategy in selecting respirators from an initial array of seven NIOSH-certified Type N95 filtering-facepiece devices for a respiratory protection program against Mycobacterium tuberculosis (M. tb) aerosol. The seven respirators were screened based on manufacturer-provided fit test data, comfort, and cost. From these 7 devices, 5 were chosen for quantitative fit testing on 40 subjects who were a convenience sample from a cohort of approximately 30,000 workers scheduled to undergo fit testing. Across the five brands, medium/regular-size respirators fit from 8% to 95% of the subjects; providing another size of the same brand improved the pass rates slightly. Gender was not found to significantly affect fit test pass rates for any respirator brand. Among test panel members, an Aearo Corporation respirator (TC 84A-2630) and a 3M Company respirator (TC 84A-0006) provided the highest overall pass rates of 98% and 90%, respectively. We selected these two brands for fit testing in the larger worker cohort. To date, these two respirators have provided overall pass rates of 98% (1793/1830) and 88% (50/57), respectively, which are similar to the test panel results. Among 1850 individuals who have been fit tested, 1843 (99.6%) have been successfully fitted with one or the other brand. In a separate analysis, we used the test panel pass rates to estimate the reduction in M. tb infection risk afforded by the medium/regular-size of five filtering-facepiece respirators. We posed a low-exposure versus a high-exposure scenario for health care workers and assumed that respirators could be assigned without conducting fit testing, as proposed by many hospital infection control practitioners. Among those who would pass versus fail the fit test, we assumed an average

  3. Bench-top validation testing of selected immunological and molecular Renibacterium salmoninarum diagnostic assays by comparison with quantitative bacteriological culture

    USGS Publications Warehouse

    Elliott, D.G.; Applegate, L.J.; Murray, A.L.; Purcell, M.K.; McKibben, C.L.

    2013-01-01

    No gold standard assay exhibiting error-free classification of results has been identified for detection of Renibacterium salmoninarum, the causative agent of salmonid bacterial kidney disease. Validation of diagnostic assays for R. salmoninarum has been hindered by its unique characteristics and biology, and difficulties in locating suitable populations of reference test animals. Infection status of fish in test populations is often unknown, and it is commonly assumed that the assay yielding the most positive results has the highest diagnostic accuracy, without consideration of misclassification of results. In this research, quantification of R. salmoninarum in samples by bacteriological culture provided a standardized measure of viable bacteria to evaluate analytical performance characteristics (sensitivity, specificity and repeatability) of non-culture assays in three matrices (phosphate-buffered saline, ovarian fluid and kidney tissue). Non-culture assays included polyclonal enzyme-linked immunosorbent assay (ELISA), direct smear fluorescent antibody technique (FAT), membrane-filtration FAT, nested polymerase chain reaction (nested PCR) and three real-time quantitative PCR assays. Injection challenge of specific pathogen-free Chinook salmon, Oncorhynchus tshawytscha (Walbaum), with R. salmoninarum was used to estimate diagnostic sensitivity and specificity. Results did not identify a single assay demonstrating the highest analytical and diagnostic performance characteristics, but revealed strengths and weaknesses of each test.

  4. Quantitative pilomotor axon reflex test: a novel test of pilomotor function.

    PubMed

    Siepmann, Timo; Gibbons, Christopher H; Illigens, Ben M; Lafo, Jacob A; Brown, Christopher M; Freeman, Roy

    2012-11-01

    Cutaneous autonomic function can be quantified by the assessment of sudomotor and vasomotor responses. Although piloerector muscles are innervated by the sympathetic nervous system, there are at present no methods to quantify pilomotor function. To quantify piloerection using phenylephrine hydrochloride in humans. Pilot study. Hospital-based study. Twenty-two healthy volunteers (18 males,4 females) aged 24 to 48 years participated in 6 studies. Piloerection was stimulated by iontophoresis of 1% phenylephrine. Silicone impressions of piloerection were quantified by number and area. The direct and indirect responses to phenylephrine iontophoresis were compared on both forearms after pre treatment to topical and subcutaneous lidocaine and iontophoresis of normal saline. Iontophoresis of phenylephrine induced piloerection in both the direct and axon reflex–mediated regions, with similar responses in both arms. Topical lidocaine blocked axon reflex–mediated piloerection post-iontophoresis (mean [SD], 66.6 [19.2] for control impressions vs 7.2 [4.3] for lidocaine impressions;P.001). Subcutaneous lidocaine completely blocked piloerection.The area of axon reflex–mediated piloerection was also attenuated in the lidocaine-treated region postiontophoresis (mean [SD], 46.2 [16.1]cm2 vs 7.2 [3.9]cm2; P.001). Piloerection was delayed in the axon reflex region compared with the direct region. Normal saline did not cause piloerection. Phenylephrine provoked piloerection directly and indirectly through an axon reflex–mediated response that is attenuated by lidocaine. Piloerection is not stimulated by iontophoresis of normal saline alone.The quantitative pilomotor axon reflex test (QPART) may complement other measures of cutaneous autonomic nerve fiber function.

  5. Physical basis of tap test as a quantitative imaging tool for composite structures on aircraft

    NASA Astrophysics Data System (ADS)

    Hsu, David K.; Barnard, Daniel J.; Peters, John J.; Dayal, Vinay

    2000-05-01

    Tap test is a simple but effective way for finding flaws in composite and honeycomb sandwich structures; it has been practiced in aircraft inspection for decades. The mechanics of tap test was extensively researched by P. Cawley et al., and several versions of instrumented tap test have emerged in recent years. This paper describes a quantitative study of the impact duration as a function of the mass, radius, velocity, and material property of the impactor. The impact response is compared to the predictions of Hertzian-type contact theory and a simple spring model. The electronically measured impact duration, τ, is used for generating images of the tapped region. Using the spring model, the images are converted into images of a spring constant, k, which is a measure of the local contact stiffness. The images of k, largely independent of tapper mass and impact velocity, reveal the size, shape and severity (cf. Percent stiffness reduction) of defects and damages, as well as the presence of substructures and the associated stiffness increase. The studies are carried out on a variety of real aircraft components and the results serve to guide the development of a fieldable tap test imaging system for aircraft inspection.—This material is based upon work supported by the Federal Aviation Administration under Contract #DTFA03-98-D-00008, Delivery Order No. IA016 and performed at Iowa State University's Center for NDE as part of the Center for Aviation Systems Reliability program.

  6. Test-retest reliability of quantitative sensory testing for mechanical somatosensory and pain modulation assessment of masticatory structures.

    PubMed

    Costa, Y M; Morita-Neto, O; de Araújo-Júnior, E N S; Sampaio, F A; Conti, P C R; Bonjardim, L R

    2017-03-01

    Assessing the reliability of medical measurements is a crucial step towards the elaboration of an applicable clinical instrument. There are few studies that evaluate the reliability of somatosensory assessment and pain modulation of masticatory structures. This study estimated the test-retest reliability, that is over time, of the mechanical somatosensory assessment of anterior temporalis, masseter and temporomandibular joint (TMJ) and the conditioned pain modulation (CPM) using the anterior temporalis as the test site. Twenty healthy women were evaluated in two sessions (1 week apart) by the same examiner. Mechanical detection threshold (MDT), mechanical pain threshold (MPT), wind-up ratio (WUR) and pressure pain threshold (PPT) were assessed on the skin overlying the anterior temporalis, masseter and TMJ of the dominant side. CPM was tested by comparing PPT before and during the hand immersion in a hot water bath. anova and intra-class correlation coefficients (ICCs) were applied to the data (α = 5%). The overall ICCs showed acceptable values for the test-retest reliability of mechanical somatosensory assessment of masticatory structures. The ICC values of 75% of all quantitative sensory measurements were considered fair to excellent (fair = 8·4%, good = 33·3% and excellent = 33·3%). However, the CPM paradigm presented poor reliability (ICC = 0·25). The mechanical somatosensory assessment of the masticatory structures, but not the proposed CPM protocol, can be considered sufficiently reliable over time to evaluate the trigeminal sensory function. © 2016 John Wiley & Sons Ltd.

  7. Ecosystem functioning and maximum entropy production: a quantitative test of hypotheses.

    PubMed

    Meysman, Filip J R; Bruers, Stijn

    2010-05-12

    The idea that entropy production puts a constraint on ecosystem functioning is quite popular in ecological thermodynamics. Yet, until now, such claims have received little quantitative verification. Here, we examine three 'entropy production' hypotheses that have been forwarded in the past. The first states that increased entropy production serves as a fingerprint of living systems. The other two hypotheses invoke stronger constraints. The state selection hypothesis states that when a system can attain multiple steady states, the stable state will show the highest entropy production rate. The gradient response principle requires that when the thermodynamic gradient increases, the system's new stable state should always be accompanied by a higher entropy production rate. We test these three hypotheses by applying them to a set of conventional food web models. Each time, we calculate the entropy production rate associated with the stable state of the ecosystem. This analysis shows that the first hypothesis holds for all the food webs tested: the living state shows always an increased entropy production over the abiotic state. In contrast, the state selection and gradient response hypotheses break down when the food web incorporates more than one trophic level, indicating that they are not generally valid.

  8. Radiative, actively cooled panel tests results

    NASA Technical Reports Server (NTRS)

    Shore, C. P.; Nowak, R. J.; Sharpe, E. L.

    1978-01-01

    The radiative, actively cooled panel designed to withstand a uniform incident heat flux of 136 kW/sq m to a 444 K surface temperature was evaluated. The test program consisted of preliminary static thermal mechanical loading and aerothermal flow tests. Test results are briefly discussed.

  9. From themes to hypotheses: following up with quantitative methods.

    PubMed

    Morgan, David L

    2015-06-01

    One important category of mixed-methods research designs consists of quantitative studies that follow up on qualitative research. In this case, the themes that serve as the results from the qualitative methods generate hypotheses for testing through the quantitative methods. That process requires operationalization to translate the concepts from the qualitative themes into quantitative variables. This article illustrates these procedures with examples that range from simple operationalization to the evaluation of complex models. It concludes with an argument for not only following up qualitative work with quantitative studies but also the reverse, and doing so by going beyond integrating methods within single projects to include broader mutual attention from qualitative and quantitative researchers who work in the same field. © The Author(s) 2015.

  10. Quantitative tests for plate tectonics on Venus

    NASA Technical Reports Server (NTRS)

    Kaula, W. M.; Phillips, R. J.

    1981-01-01

    Quantitative comparisons are made between the characteristics of plate tectonics on the earth and those which are possible on Venus. Considerations of the factors influencing rise height and relating the decrease in rise height to plate velocity indicate that the rate of topographic dropoff from spreading centers should be about half that on earth due to greater rock-fluid density contrast and lower temperature differential between the surface and interior. Statistical analyses of Pioneer Venus radar altimetry data and global earth elevation data is used to identify 21,000 km of ridge on Venus and 33,000 km on earth, and reveal Venus ridges to have a less well-defined mode in crest heights and a greater concavity than earth ridges. Comparison of the Venus results with the spreading rates and associated heat flow on earth reveals plate creation rates on Venus to be 0.7 sq km/year or less and indicates that not more than 15% of Venus's energy is delivered to the surface by plate tectonics, in contrast to values of 2.9 sq km a year and 70% for earth.

  11. Ordering Molecular Genetic Tests and Reporting Results

    PubMed Central

    Lubin, Ira M.; Caggana, Michele; Constantin, Carolyn; Gross, Susan J.; Lyon, Elaine; Pagon, Roberta A.; Trotter, Tracy L.; Wilson, Jean Amos; McGovern, Margaret M.

    2008-01-01

    Previous studies have suggested that patient care may be compromised as a consequence of poor communication between clinicians and laboratory professionals in cases in which molecular genetic test results are reported. To understand better the contributing factors to such compromised care, we investigated both pre- and postanalytical processes using cystic fibrosis mutation analysis as our model. We found that although the majority of test requisition forms requested patient/family information that was necessary for the proper interpretation of test results, in many cases, these data were not provided by the individuals filling out the forms. We found instances in which result reports for simulated diagnostic testing described individuals as carriers where only a single mutation was found with no comment pertaining to a diagnosis of cystic fibrosis. Similarly, reports based on simulated scenarios for carrier testing were problematic when no mutations were identified, and the patient's race/ethnicity and family history were not discussed in reference to residual risk of disease. Remarkably, a pilot survey of obstetrician-gynecologists revealed that office staff, including secretaries, often helped order genetic tests and reported test results to patients, raising questions about what efforts are undertaken to ensure personnel competency. These findings are reviewed in light of what efforts should be taken to improve the quality of test-ordering and result-reporting practices. PMID:18669879

  12. Utility of DWI with quantitative ADC values in ovarian tumors: a meta-analysis of diagnostic test performance.

    PubMed

    Pi, Shan; Cao, Rong; Qiang, Jin Wei; Guo, Yan Hui

    2018-01-01

    Background Diffusion-weighted imaging (DWI) and quantitative apparent diffusion coefficient (ADC) values are widely used in the differential diagnosis of ovarian tumors. Purpose To assess the diagnostic performance of quantitative ADC values in ovarian tumors. Material and Methods PubMed, Embase, the Cochrane Library, and local databases were searched for studies assessing ovarian tumors using quantitative ADC values. We quantitatively analyzed the diagnostic performances for two clinical problems: benign vs. malignant tumors and borderline vs. malignant tumors. We evaluated diagnostic performances by the pooled sensitivity and specificity values and by summary receiver operating characteristic (SROC) curves. Subgroup analyses were used to analyze study heterogeneity. Results From the 742 studies identified in the search results, 16 studies met our inclusion criteria. A total of ten studies evaluated malignant vs. benign ovarian tumors and six studies assessed malignant vs. borderline ovarian tumors. Regarding the diagnostic accuracy of quantitative ADC values for distinguishing between malignant and benign ovarian tumors, the pooled sensitivity and specificity values were 0.91 and 0.91, respectively. The area under the SROC curve (AUC) was 0.96. For differentiating borderline from malignant tumors, the pooled sensitivity and specificity values were 0.89 and 0.79, and the AUC was 0.91. The methodological quality of the included studies was moderate. Conclusion Quantitative ADC values could serve as useful preoperative markers for predicting the nature of ovarian tumors. Nevertheless, prospective trials focused on standardized imaging parameters are needed to evaluate the clinical value of quantitative ADC values in ovarian tumors.

  13. Altered quantitative sensory testing outcome in subjects with opioid therapy.

    PubMed

    Chen, Lucy; Malarick, Charlene; Seefeld, Lindsey; Wang, Shuxing; Houghton, Mary; Mao, Jianren

    2009-05-01

    Preclinical studies have suggested that opioid exposure may induce a paradoxical decrease in the nociceptive threshold, commonly referred as opioid-induced hyperalgesia (OIH). While OIH may have implications in acute and chronic pain management, its clinical features remain unclear. Using an office-based quantitative sensory testing (QST) method, we compared pain threshold, pain tolerance, and the degree of temporal summation of the second pain in response to thermal stimulation among three groups of subjects: those with neither pain nor opioid therapy (group 1), with chronic pain but without opioid therapy (group 2), and with both chronic pain and opioid therapy (group 3). We also examined the possible correlation between QST responses to thermal stimulation and opioid dose, opioid treatment duration, opioid analgesic type, pain duration, or gender in group 3 subjects. As compared with both group 1 (n=41) and group 2 (n=41) subjects, group 3 subjects (n=58) displayed a decreased heat pain threshold and exacerbated temporal summation of the second pain to thermal stimulation. In contrast, there were no differences in cold or warm sensation among three groups. Among clinical factors, daily opioid dose consistently correlated with the decreased heat pain threshold and exacerbated temporal summation of the second pain in group 3 subjects. These results indicate that decreased heat pain threshold and exacerbated temporal summation of the second pain may be characteristic QST changes in subjects with opioid therapy. The data suggest that QST may be a useful tool in the clinical assessment of OIH.

  14. Statistical Issues in Testing Conformance with the Quantitative Imaging Biomarker Alliance (QIBA) Profile Claims.

    PubMed

    Obuchowski, Nancy A; Buckler, Andrew; Kinahan, Paul; Chen-Mayer, Heather; Petrick, Nicholas; Barboriak, Daniel P; Bullen, Jennifer; Barnhart, Huiman; Sullivan, Daniel C

    2016-04-01

    A major initiative of the Quantitative Imaging Biomarker Alliance is to develop standards-based documents called "Profiles," which describe one or more technical performance claims for a given imaging modality. The term "actor" denotes any entity (device, software, or person) whose performance must meet certain specifications for the claim to be met. The objective of this paper is to present the statistical issues in testing actors' conformance with the specifications. In particular, we present the general rationale and interpretation of the claims, the minimum requirements for testing whether an actor achieves the performance requirements, the study designs used for testing conformity, and the statistical analysis plan. We use three examples to illustrate the process: apparent diffusion coefficient in solid tumors measured by MRI, change in Perc 15 as a biomarker for the progression of emphysema, and percent change in solid tumor volume by computed tomography as a biomarker for lung cancer progression. Copyright © 2016 The Association of University Radiologists. All rights reserved.

  15. Rockwell-Rocketdyne flywheel test results

    NASA Astrophysics Data System (ADS)

    Steele, R. S., Jr.; Babelay, E. F., Jr.; Sutton, B. J.

    1981-01-01

    Results are presented of the spin test evaluation of the Rockwell-Rocketdyne RPE-10 design flywheel at the Oak Ridge Flywheel Evaluation Laboratory. Details of the static evaluation, including measures of weight, inertia, natural frequencies, and radiography, are also presented. The flywheel was subjected to seven spin cycles with a maximum of 383 rps, 105% of design speed. At that speed, the energy stored was 1.94 kWhr at 36.1 Whr/kg. The maximum speed was limited by the inability of the test facility to accommodate the increasing eccentric shift of both hub disks with increasing speed. No material degradation was observed during the testing.

  16. Slow erosion of a quantitative apple resistance to Venturia inaequalis based on an isolate-specific Quantitative Trait Locus.

    PubMed

    Caffier, Valérie; Le Cam, Bruno; Al Rifaï, Mehdi; Bellanger, Marie-Noëlle; Comby, Morgane; Denancé, Caroline; Didelot, Frédérique; Expert, Pascale; Kerdraon, Tifenn; Lemarquand, Arnaud; Ravon, Elisa; Durel, Charles-Eric

    2016-10-01

    Quantitative plant resistance affects the aggressiveness of pathogens and is usually considered more durable than qualitative resistance. However, the efficiency of a quantitative resistance based on an isolate-specific Quantitative Trait Locus (QTL) is expected to decrease over time due to the selection of isolates with a high level of aggressiveness on resistant plants. To test this hypothesis, we surveyed scab incidence over an eight-year period in an orchard planted with susceptible and quantitatively resistant apple genotypes. We sampled 79 Venturia inaequalis isolates from this orchard at three dates and we tested their level of aggressiveness under controlled conditions. Isolates sampled on resistant genotypes triggered higher lesion density and exhibited a higher sporulation rate on apple carrying the resistance allele of the QTL T1 compared to isolates sampled on susceptible genotypes. Due to this ability to select aggressive isolates, we expected the QTL T1 to be non-durable. However, our results showed that the quantitative resistance based on the QTL T1 remained efficient in orchard over an eight-year period, with only a slow decrease in efficiency and no detectable increase of the aggressiveness of fungal isolates over time. We conclude that knowledge on the specificity of a QTL is not sufficient to evaluate its durability. Deciphering molecular mechanisms associated with resistance QTLs, genetic determinants of aggressiveness and putative trade-offs within pathogen populations is needed to help in understanding the erosion processes. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. The breaking load method - Results and statistical modification from the ASTM interlaboratory test program

    NASA Technical Reports Server (NTRS)

    Colvin, E. L.; Emptage, M. R.

    1992-01-01

    The breaking load test provides quantitative stress corrosion cracking data by determining the residual strength of tension specimens that have been exposed to corrosive environments. Eight laboratories have participated in a cooperative test program under the auspices of ASTM Committee G-1 to evaluate the new test method. All eight laboratories were able to distinguish between three tempers of aluminum alloy 7075. The statistical analysis procedures that were used in the test program do not work well in all situations. An alternative procedure using Box-Cox transformations shows a great deal of promise. An ASTM standard method has been drafted which incorporates the Box-Cox procedure.

  18. Quantitative EEG analysis using error reduction ratio-causality test; validation on simulated and real EEG data.

    PubMed

    Sarrigiannis, Ptolemaios G; Zhao, Yifan; Wei, Hua-Liang; Billings, Stephen A; Fotheringham, Jayne; Hadjivassiliou, Marios

    2014-01-01

    To introduce a new method of quantitative EEG analysis in the time domain, the error reduction ratio (ERR)-causality test. To compare performance against cross-correlation and coherence with phase measures. A simulation example was used as a gold standard to assess the performance of ERR-causality, against cross-correlation and coherence. The methods were then applied to real EEG data. Analysis of both simulated and real EEG data demonstrates that ERR-causality successfully detects dynamically evolving changes between two signals, with very high time resolution, dependent on the sampling rate of the data. Our method can properly detect both linear and non-linear effects, encountered during analysis of focal and generalised seizures. We introduce a new quantitative EEG method of analysis. It detects real time levels of synchronisation in the linear and non-linear domains. It computes directionality of information flow with corresponding time lags. This novel dynamic real time EEG signal analysis unveils hidden neural network interactions with a very high time resolution. These interactions cannot be adequately resolved by the traditional methods of coherence and cross-correlation, which provide limited results in the presence of non-linear effects and lack fidelity for changes appearing over small periods of time. Copyright © 2013 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  19. Effect of once-yearly zoledronic acid on the spine and hip as measured by quantitative computed tomography: results of the HORIZON Pivotal Fracture Trial

    PubMed Central

    Lang, T.; Boonen, S.; Cummings, S.; Delmas, P. D.; Cauley, J. A.; Horowitz, Z.; Kerzberg, E.; Bianchi, G.; Kendler, D.; Leung, P.; Man, Z.; Mesenbrink, P.; Eriksen, E. F.; Black, D. M.

    2016-01-01

    Summary Changes in bone mineral density and bone strength following treatment with zoledronic acid (ZOL) were measured by quantitative computed analysis (QCT) or dual-energy X-ray absorptiometry (DXA). ZOL treatment increased spine and hip BMD vs placebo, assessed by QCT and DXA. Changes in trabecular bone resulted in increased bone strength. Introduction To investigate bone mineral density (BMD) changes in trabecular and cortical bone, estimated by quantitative computed analysis (QCT) or dual-energy X-ray absorptiometry (DXA), and whether zoledronic acid 5 mg (ZOL) affects bone strength. Methods In 233 women from a randomized, controlled trial of once-yearly ZOL, lumbar spine, total hip, femoral neck, and trochanter were assessed by DXA and QCT (baseline, Month 36). Mean percentage changes from baseline and between-treatment differences (ZOL vs placebo, t-test) were evaluated. Results Mean between-treatment differences for lumbar spine BMD were significant by DXA (7.0%, p<0.01) and QCT (5.7%, p<0.0001). Between-treatment differences were significant for trabecular spine (p=0.0017) [non-parametric test], trabecular trochanter (10.7%, p<0.0001), total hip (10.8%, p<0.0001), and compressive strength indices at femoral neck (8.6%, p=0.0001), and trochanter (14.1%, p<0.0001). Conclusions Once-yearly ZOL increased hip and spine BMD vs placebo, assessed by QCT vs DXA. Changes in trabecular bone resulted in increased indices of compressive strength. PMID:19802508

  20. A simple quantitative diagnostic alternative for MGMT DNA-methylation testing on RCL2 fixed paraffin embedded tumors using restriction coupled qPCR.

    PubMed

    Pulverer, Walter; Hofner, Manuela; Preusser, Matthias; Dirnberger, Elisabeth; Hainfellner, Johannes A; Weinhaeusel, Andreas

    2014-01-01

    MGMT promoter methylation is associated with favorable prognosis and chemosensitivity in glioblastoma multiforme (GBM), especially in elderly patients. We aimed to develop a simple methylation-sensitive restriction enzyme (MSRE)-based quantitative PCR (qPCR) assay, allowing the quantification of MGMT promoter methylation. DNA was extracted from non-neoplastic brain (n = 24) and GBM samples (n = 20) upon 3 different sample conservation conditions (-80 °C, formalin-fixed and paraffin-embedded (FFPE); RCL2-fixed). We evaluated the suitability of each fixation method with respect to the MSRE-coupled qPCR methylation analyses. Methylation data were validated by MALDITOF. qPCR was used for evaluation of alternative tissue conservation procedures. DNA from FFPE tissue failed reliable testing; DNA from both RCL2-fixed and fresh frozen tissues performed equally well and was further used for validation of the quantitative MGMT methylation assay (limit of detection (LOD): 19.58 pg), using individual's undigested sample DNA for calibration. MGMT methylation analysis in non-neoplastic brain identified a background methylation of 0.10 ± 11% which we used for defining a cut-off of 0.32% for patient stratification. Of GBM patients 9 were MGMT methylationpositive (range: 0.56 - 91.95%), and 11 tested negative. MALDI-TOF measurements resulted in a concordant classification of 94% of GBM samples in comparison to qPCR. The presented methodology allows quantitative MGMT promoter methylation analyses. An amount of 200 ng DNA is sufficient for triplicate analyses including control reactions and individual calibration curves, thus excluding any DNA qualityderived bias. The combination of RCL2-fixation and quantitative methylation analyses improves pathological routine examination when histological and molecular analyses on limited amounts of tumor samples are necessary for patient stratification.

  1. Relationships among Testing Medium, Test Performance, and Testing Time of High School Students Who Are Visually Impaired

    ERIC Educational Resources Information Center

    Erin, Jane N.; Hong, Sunggye; Schoch, Christina; Kuo, YaJu

    2006-01-01

    This study compared the test scores and time required by high school students who are blind, sighted, or have low vision to complete tests administered in written and oral formats. The quantitative results showed that the blind students performed better on multiple-choice tests in braille and needed more time while taking tests in braille. The…

  2. Rockwell-Rocketdyne flywheel test results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steele, R.S. Jr.; Babelay, E.F. Jr.; Sutton, B.J.

    1981-01-01

    Results are presented of the spin test evaluation of the Rockwell-Rocketdyne RPE-10 design flywheel at the Oak Ridge Flywheel Evaluation Laboratory. Details of the static evaluation, including measures of weight, inertia, natural frequencies, and radiography, are also presented. The flywheel was subjected to seven spin cycles with a maximum of 383 rps, 105% of design speed. At that speed, the energy stored was 1.94 kWhr at 36.1 Whr/kg. The maximum speed was limited by the inability of the test facility to accommodate the increasing eccentric shift of both hub disks with increasing speed. No material degradation was observed during themore » testing.« less

  3. Calculator Use on the "GRE"® Revised General Test Quantitative Reasoning Measure. ETS GRE® Board Research Report. ETS GRE®-14-02. ETS Research Report. RR-14-25

    ERIC Educational Resources Information Center

    Attali, Yigal

    2014-01-01

    Previous research on calculator use in standardized assessments of quantitative ability focused on the effect of calculator availability on item difficulty and on whether test developers can predict these effects. With the introduction of an on-screen calculator on the Quantitative Reasoning measure of the "GRE"® revised General Test, it…

  4. Results of steel containment vessel model test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luk, V.K.; Ludwigsen, J.S.; Hessheimer, M.F.

    A series of static overpressurization tests of scale models of nuclear containment structures is being conducted by Sandia National Laboratories for the Nuclear Power Engineering Corporation of Japan and the US Nuclear Regulatory Commission. Two tests are being conducted: (1) a test of a model of a steel containment vessel (SCV) and (2) a test of a model of a prestressed concrete containment vessel (PCCV). This paper summarizes the conduct of the high pressure pneumatic test of the SCV model and the results of that test. Results of this test are summarized and are compared with pretest predictions performed bymore » the sponsoring organizations and others who participated in a blind pretest prediction effort. Questions raised by this comparison are identified and plans for posttest analysis are discussed.« less

  5. Test-retest agreement and reliability of quantitative sensory testing 1 year after breast cancer surgery.

    PubMed

    Andersen, Kenneth Geving; Kehlet, Henrik; Aasvang, Eske Kvanner

    2015-05-01

    Quantitative sensory testing (QST) is used to assess sensory dysfunction and nerve damage by examining psychophysical responses to controlled, graded stimuli such as mechanical and thermal detection and pain thresholds. In the breast cancer population, 4 studies have used QST to examine persistent pain after breast cancer treatment, suggesting neuropathic pain being a prominent pain mechanism. However, the agreement and reliability of QST has not been described in the postsurgical breast cancer population, hindering exact interpretation of QST studies in this population. The aim of the present study was to assess test-retest properties of QST after breast cancer surgery. A total of 32 patients recruited from a larger ongoing prospective trial were examined with QST 12 months after breast cancer surgery and reexamined a week later. A standardized QST protocol was used, including sensory mapping for mechanical, warmth and cold areas of sensory dysfunction, mechanical thresholds using monofilaments and pin-prick, thermal thresholds including warmth and cold detection thresholds and heat pain threshold, with bilateral examination. Agreement and reliability were assessed by Bland-Altman plots, descriptive statistics, coefficients of variance, and intraclass correlation. Bland-Altman plots showed high variation on the surgical side. Intraclass coefficients ranged from 0.356 to 0.847 (moderate to substantial reliability). Between-patient variation was generally higher (0.9 to 14.5 SD) than within-patient variation (0.23 to 3.55 SD). There were no significant differences between pain and pain-free patients. The individual test-retest variability was higher on the operated side compared with the nonoperated side. The QST protocol reliability allows for group-to-group comparison of sensory function, but less so for individual follow-up after breast cancer surgery.

  6. Analysis of cytomegalovirus (CMV) viremia using the pp65 antigenemia assay, the amplicor CMV test, and a semi-quantitative polymerase chain reaction test after allogeneic marrow transplantation.

    PubMed

    Ksouri, H; Eljed, H; Greco, A; Lakhal, A; Torjman, L; Abdelkefi, A; Ben Othmen, T; Ladeb, S; Slim, A; Zouari, B; Abdeladhim, A; Ben Hassen, A

    2007-03-01

    A pp65 antigenemia assay for polymorphonuclear leukocytes (PMNLs) (CINAkit Rapid Antigenemia), and a qualitative polymerase chain reaction (PCR) test for plasma 'PCR-P qual' (Amplicor cytomegalovirus [CMV] test) were performed for 126 samples (blood and plasma) obtained from 18 bone marrow transplant patients, over a 9-month surveillance period. Among those samples, 92 were assayed with a semi-quantitative PCR test for PMNLs 'PCR-L quant.' The number of samples with a positive CMV test for antigenemia and PCR-P qual assays was 20.63% and 12.7%, respectively, whereas the PCR-L quant assay was positive in 48 of the 92 samples assayed (52.17%). The rates of concordance of the results of PCR-P qual and antigenemia, PCR-P qual and PCR-L quant, antigenemia and PCR-L quant were 92%, 65.2% and 66.8%, respectively. The analysis of the results for the 92 specimens tested by all 3 methods showed a rate of concordance of 63% among all methods. Good agreement (kappa=0.72) was found only between pp65 Ag and PCR-P qual assays. Clinical disease correlates with an antigenemia high viral load. Three patients had CMV disease despite preemptive therapy, and all of them had graft-versus-host-disease (GVHD). PMNLs-based assays are more efficient in monitoring CMV reactivation, but for high-risk patients with GVHD, more sensitive assays (real-time PCR) must be done.

  7. Quantitative Testing of Bedrock Incision Models, Clearwater River, WA

    NASA Astrophysics Data System (ADS)

    Tomkin, J. H.; Brandon, M.; Pazzaglia, F.; Barbour, J.; Willet, S.

    2001-12-01

    The topographic evolution of many active orogens is dominated by the process of bedrock channel incision. Several incision models based around the detachment limited shear-stress model (or stream power model) which employs an area (A) and slope (S) power law (E = K Sn Am) have been proposed to explain this process. They require quantitative assessment. We evaluate the proposed incision models by comparing their predictions with observations obtained from a river in a tectonically active mountain range: the Clearwater River in northwestern Washington State. Previous work on river terraces along the Clearwater have provided long-term incision rates for the river, and in conjunction with previous fission track studies it has also been determined that there is a long-term balance between river incision and rock uplift. This steady-state incision rate data allows us, through the use of inversion methods and statistical tests, to determine the applicability of the different incision models for the Clearwater. None of the models successfully explain the observations. This conclusion particularly applies to the commonly used detachment limited shear-stress model (or stream power model), which has a physically implausible best fit solution and systematic residuals for all the predicted combinations of m and n.

  8. Advanced Thermal Simulator Testing: Thermal Analysis and Test Results

    NASA Technical Reports Server (NTRS)

    Bragg-Sitton, Shannon M.; Dickens, Ricky; Dixon, David; Reid, Robert; Adams, Mike; Davis, Joe

    2008-01-01

    Work at the NASA Marshall Space Flight Center seeks to develop high fidelity, electrically heated thermal simulators that represent fuel elements in a nuclear reactor design to support non-nuclear testing applicable to the development of a space nuclear power or propulsion system. Comparison between the fuel pins and thermal simulators is made at the outer fuel clad surface, which corresponds to the outer sheath surface in the thermal simulator. The thermal simulators that are currently being tested correspond to a SNAP derivative reactor design that could be applied for Lunar surface power. These simulators are designed to meet the geometric and power requirements of a proposed surface power reactor design, accommodate testing of various axial power profiles, and incorporate imbedded instrumentation. This paper reports the results of thermal simulator analysis and testing in a bare element configuration, which does not incorporate active heat removal, and testing in a water-cooled calorimeter designed to mimic the heat removal that would be experienced in a reactor core.

  9. Introduction to Quantitative Science, a Ninth-Grade Laboratory-Centered Course Stressing Quantitative Observation and Mathematical Analysis of Experimental Results. Final Report.

    ERIC Educational Resources Information Center

    Badar, Lawrence J.

    This report, in the form of a teacher's guide, presents materials for a ninth grade introductory course on Introduction to Quantitative Science (IQS). It is intended to replace a traditional ninth grade general science with a process oriented course that will (1) unify the sciences, and (2) provide a quantitative preparation for the new science…

  10. Guidelines for Reporting Quantitative Methods and Results in Primary Research

    ERIC Educational Resources Information Center

    Norris, John M.; Plonsky, Luke; Ross, Steven J.; Schoonen, Rob

    2015-01-01

    Adequate reporting of quantitative research about language learning involves careful consideration of the logic, rationale, and actions underlying both study designs and the ways in which data are analyzed. These guidelines, commissioned and vetted by the board of directors of "Language Learning," outline the basic expectations for…

  11. Quantitative characterization of the interfacial adhesion of Ni thin film on steel substrate: A compression-induced buckling delamination test

    NASA Astrophysics Data System (ADS)

    Zhu, W.; Zhou, Y. C.; Guo, J. W.; Yang, L.; Lu, C.

    2015-01-01

    A compression-induced buckling delamination test is employed to quantitatively characterize the interfacial adhesion of Ni thin film on steel substrate. It is shown that buckles initiate from edge flaws and surface morphologies exhibit symmetric, half-penny shapes. Taking the elastoplasticity of film and substrate into account, a three-dimensional finite element model for an edge flaw with the finite size is established to simulate the evolution of energy release rates and phase angles in the process of interfacial buckling-driven delamination. The results show that delamination propagates along both the straight side and curved front. The mode II delamination plays a dominant role in the process with a straight side whilst the curved front experiences almost the pure mode I. Based on the results of finite element analysis, a numerical model is developed to evaluate the interfacial energy release rate, which is in the range of 250-315 J/m2 with the corresponding phase angle from -41° to -66°. These results are in agreement with the available values determined by other testing methods, which confirms the effectiveness of the numerical model.

  12. Feasibility and repeatability of cold and mechanical quantitative sensory testing in normal dogs

    PubMed Central

    Briley, Jessica D.; Williams, Morika D.; Freire, Mila; Griffith, Emily H.; Lascelles, B. Duncan X.

    2015-01-01

    Feasibility and inter-session repeatability of cold and mechanical quantitative sensory testing (QST) were assessed in 24 normal dogs. Cold thermal latencies were evaluated using a thermal probe (0 °C) applied to three pelvic limb sites. Mechanical thresholds were measured using an electronic von Frey anesthesiometer (EVF) and a blunt-probed pressure algometer (PA) applied to the dorsal aspect of the metatarsus. All QST trials were performed with dogs in lateral recumbency. Collection of cold QST data was easy (feasible) in 19/24 (79%) dogs. However, only 18.4%, 18.9% and 13.2% of cold QST trials elicited a response at the medial tibia, third digital pad and plantar metatarsal regions, respectively. Collection of mechanical QST data was easy (feasible) in 20/24 (83%) dogs for both EVF and PA. At consecutive sampling times, approximately 2 weeks apart, the average EVF sensory thresholds were 414 ± 186 g and 379 ± 166 g, respectively, and the average PA sensory thresholds were 1089 ± 414 g and 1028 ± 331 g, respectively. There was no significant difference in inter-session or inter-limb threshold values for either mechanical QST device. The cold QST protocol in this study was achievable, but did not provide consistently quantifiable results. Both mechanical QST devices tested provided repeatable, reliable sensory threshold measurements in normal, client-owned dogs. These findings contribute to the validation of the EVF and PA as tools to obtain repeated QST data over time in dogs to assess somatosensory processing changes. PMID:24268475

  13. 49 CFR 234.273 - Results of inspections and tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Results of inspections and tests. 234.273 Section....273 Results of inspections and tests. (a) Results of inspections and tests made in compliance with.../DOT inventory number, place and date, equipment tested, results of tests, repairs, replacements...

  14. 49 CFR 234.273 - Results of inspections and tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Results of inspections and tests. 234.273 Section....273 Results of inspections and tests. (a) Results of inspections and tests made in compliance with.../DOT inventory number, place and date, equipment tested, results of tests, repairs, replacements...

  15. 49 CFR 234.273 - Results of inspections and tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Results of inspections and tests. 234.273 Section....273 Results of inspections and tests. (a) Results of inspections and tests made in compliance with.../DOT inventory number, place and date, equipment tested, results of tests, repairs, replacements...

  16. QUANTITATIVE TEMPLATE FOR SUBTYPING PRIMARY PROGRESSIVE APHASIA

    PubMed Central

    Mesulam, Marsel; Wieneke, Christina; Rogalski, Emily; Cobia, Derin; Thompson, Cynthia; Weintraub, Sandra

    2009-01-01

    Objective To provide a quantitative algorithm for classifying primary progressive aphasia (PPA) into agrammatic (PPA-G), semantic (PPA-S) and logopenic (PPA-L) variants, each of which is known to have a different probability of association with Alzheimer’s disease (AD) versus frontotemporal lobar degeneration (FTLD). Design Prospectively and consecutively enrolled 16 PPA patients tested with neuropsychological instruments and magnetic resonance imaging (MRI). Setting University medical center. Participants PPA patients recruited nationally in the USA as part of a longitudinal study. Results A two-dimensional template, reflecting performance on tests of syntax (Northwestern Anagram Test) and lexical semantics (Peabody Picture Vocabulary Test), classified all 16 patients in concordance with a clinical diagnosis that had been made prior to the administration of the quantitative tests. All three subtypes had distinctly asymmetrical atrophy of the left perisylvian language network. Each subtype also had distinctive peak atrophy sites. Only PPA-G had peak atrophy in the IFG (Broca’s area), only PPA-S had peak atrophy in the anterior temporal lobe, and only PPA-L had peak atrophy in area 37. Conclusions Once an accurate root diagnosis of PPA is made, subtyping can be quantitatively guided using a two-dimensional template based on orthogonal tasks of grammatical competence and word comprehension. Although the choice of tasks and precise cut-off levels may evolve in time, this set of 16 patients demonstrates the feasibility of using a simple algorithm for clinico-anatomical classification in PPA. Prospective studies will show whether this suptyping can improve the clinical prediction of underlying neuropathology. PMID:20008661

  17. Quantitative genetic analysis of the bTB diagnostic single intradermal comparative cervical test (SICCT).

    PubMed

    Tsairidou, Smaragda; Brotherstone, Susan; Coffey, Mike; Bishop, Stephen C; Woolliams, John A

    2016-11-24

    Bovine tuberculosis (bTB) is a disease of significant economic importance and is a persistent animal health problem with implications for public health worldwide. Control of bTB in the UK has relied on diagnosis through the single intradermal comparative cervical test (SICCT). However, limitations in the sensitivity of this test hinder successful eradication and the control of bTB remains a major challenge. Genetic selection for cattle that are more resistant to bTB infection can assist in bTB control. The aim of this study was to conduct a quantitative genetic analysis of SICCT measurements collected during bTB herd testing. Genetic selection for bTB resistance will be partially informed by SICCT-based diagnosis; therefore it is important to know whether, in addition to increasing bTB resistance, this might also alter genetically the epidemiological characteristics of SICCT. Our main findings are that: (1) the SICCT test is robust at the genetic level, since its hierarchy and comparative nature provide substantial protection against random genetic changes that arise from genetic drift and from correlated responses among its components due to either natural or artificial selection; (2) the comparative nature of SICCT provides effective control for initial skin thickness and age-dependent differences; and (3) continuous variation in SICCT is only lowly heritable and has a weak correlation with SICCT positivity among healthy animals which was not significantly different from zero (P > 0.05). These emerging results demonstrate that genetic selection for bTB resistance is unlikely to change the probability of correctly identifying non-infected animals, i.e. the test's specificity, while reducing the overall number of cases. This study cannot exclude all theoretical risks from selection on resistance to bTB infection but the role of SICCT in disease control is unlikely to be rapidly undermined, with any adverse correlated responses expected to be weak and slow, which

  18. Non-Nuclear Validation Test Results of a Closed Brayton Cycle Test-Loop

    NASA Astrophysics Data System (ADS)

    Wright, Steven A.

    2007-01-01

    Both NASA and DOE have programs that are investigating advanced power conversion cycles for planetary surface power on the moon or Mars, or for next generation nuclear power plants on earth. Although open Brayton cycles are in use for many applications (combined cycle power plants, aircraft engines), only a few closed Brayton cycles have been tested. Experience with closed Brayton cycles coupled to nuclear reactors is even more limited and current projections of Brayton cycle performance are based on analytic models. This report describes and compares experimental results with model predictions from a series of non-nuclear tests using a small scale closed loop Brayton cycle available at Sandia National Laboratories. A substantial amount of testing has been performed, and the information is being used to help validate models. In this report we summarize the results from three kinds of tests. These tests include: 1) test results that are useful for validating the characteristic flow curves of the turbomachinery for various gases ranging from ideal gases (Ar or Ar/He) to non-ideal gases such as CO2, 2) test results that represent shut down transients and decay heat removal capability of Brayton loops after reactor shut down, and 3) tests that map a range of operating power versus shaft speed curve and turbine inlet temperature that are useful for predicting stable operating conditions during both normal and off-normal operating behavior. These tests reveal significant interactions between the reactor and balance of plant. Specifically these results predict limited speed up behavior of the turbomachinery caused by loss of load, the conditions for stable operation, and for direct cooled reactors, the tests reveal that the coast down behavior during loss of power events can extend for hours provided the ultimate heat sink remains available.

  19. Low Emissions RQL Flametube Combustor Test Results

    NASA Technical Reports Server (NTRS)

    Chang, Clarence T.; Holdeman, James D.

    2001-01-01

    The overall objective of this test program was to demonstrate and evaluate the capability of the Rich-burn/Quick-mix/Lean-burn (RQL) combustor concept for HSR applications. This test program was in support of the Pratt & Whitney and GE Aircraft Engines HSR low-NOx Combustor Program. Collaborative programs with Parker Hannifin Corporation and Textron Fuel Systems resulted in the development and testing of the high-flow low-NOx rich-burn zone fuel-to-air ratio research fuel nozzles used in this test program. Based on the results obtained in this test program, several conclusions can be made: (1) The RQL tests gave low NOx and CO emissions results at conditions corresponding to HSR cruise. (2) The Textron fuel nozzle design with optimal multiple partitioning of fuel and air circuits shows potential of providing an acceptable uniform local fuel-rich region in the rich burner. (3) For the parameters studied in this test series, the tests have shown T3 is the dominant factor in the NOx formation for RQL combustors. As T3 increases from 600 to 1100 F, EI(NOx) increases approximately three fold. (4) Factors which appear to have secondary influence on NOx formation are P4, T4, infinity(sub rb), V(sub ref,ov). (5) Low smoke numbers were measured for infinity(sub rb) of 2.0 at P4 of 120 psia.

  20. Mathematics Placement Test: Typical Results with Unexpected Outcomes

    ERIC Educational Resources Information Center

    Ingalls, Victoria

    2011-01-01

    Based on the results of a prior case-study analysis of mathematics placement at one university, the mathematics department developed and piloted a mathematics placement test. This article describes the implementation process for a mathematics placement test and further analyzes the test results for the pilot group. As an unexpected result, the…

  1. A Unified Theory of Impact Crises and Mass Extinctions: Quantitative Tests

    NASA Technical Reports Server (NTRS)

    Rampino, Michael R.; Haggerty, Bruce M.; Pagano, Thomas C.

    1997-01-01

    Several quantitative tests of a general hypothesis linking impacts of large asteroids and comets with mass extinctions of life are possible based on astronomical data, impact dynamics, and geological information. The waiting of large-body impacts on the Earth derive from the flux of Earth-crossing asteroids and comets, and the estimated size of impacts capable of causing large-scale environmental disasters, predict that impacts of objects greater than or equal to 5 km in diameter (greater than or equal to 10 (exp 7) Mt TNT equivalent) could be sufficient to explain the record of approximately 25 extinction pulses in the last 540 Myr, with the 5 recorded major mass extinctions related to impacts of the largest objects of greater than or equal to 10 km in diameter (greater than or equal to 10(exp 8) Mt Events). Smaller impacts (approximately 10 (exp 6) Mt), with significant regional environmental effects, could be responsible for the lesser boundaries in the geologic record.

  2. NCV Flow Diagnostic Test Results

    NASA Technical Reports Server (NTRS)

    Cappuccio, Mina

    1999-01-01

    There were two objectives for this test. First, was to assess the reasons why there is approximately 1.5 drag counts (cts) discrepancy between measured and computed drag improvement of the Non-linear Cruise Validation (NCV) over the Technology Concept Airplane (TCA) wing body (WB) configurations. The Navier-Stokes (N-S) pre-test predictions from Boeing Commercial Airplane Group (BCAG) show 4.5 drag cts of improvement for NCV over TCA at a lift coefficient (CL) of 0. I at Mach 2.4. The pre-test predictions from Boeing Phantom Works - Long Beach, BPW-LB, show 3.75 drag cts of improvement. BCAG used OVERFLOW and BPW-LB used CFL3D. The first test entry to validate the improvement was held at the NASA Langley Research Center (LARC) UPV;T, test number 1687. The experimental results showed that the drag improvement was only 2.6 cts, not accounting for laminar run and trip drag. This is approximately 1.5 cts less than predicted computationally. In addition to the low Reynolds Number (RN) test, there was a high RN test in the Boeing Supersonic Wind Tunnel (BSWT) of NCV and TCA. BSV@T test 647 showed that the drag improvement of NCV over TCA was also 2.6 cts, but this did account for laminar run and trip drag. Every effort needed to be done to assess if the improvement measured in LaRC UPWT and BSWT was correct. The second objective, once the first objective was met, was to assess the performance increment of NCV over TCA accounting for the associated laminar run and trip drag corrections in LaRC UPWT. We know that the configurations tested have laminar flow on portions of the wing and have trip drag due to the mechanisms used to force the flow to go from laminar to turbulent aft of the transition location.

  3. Advanced Stirling Convertor Dynamic Test Approach and Results

    NASA Technical Reports Server (NTRS)

    Meer, David W.; Hill, Dennis; Ursic, Joseph J.

    2010-01-01

    The U.S. Department of Energy (DOE), Lockheed Martin Corporation (LM), and NASA Glenn Research Center (GRC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. As part of the extended operation testing of this power system, the Advanced Stirling Convertors (ASC) at NASA GRC undergo a vibration test sequence intended to simulate the vibration history that an ASC would experience when used in an ASRG for a space mission. This sequence includes testing at workmanship and flight acceptance levels interspersed with periods of extended operation to simulate prefueling and post fueling. The final step in the test sequence utilizes additional testing at flight acceptance levels to simulate launch. To better replicate the acceleration profile seen by an ASC incorporated into an ASRG, the input spectra used in testing the convertors was modified based on dynamic testing of the ASRG Engineering Unit (ASRG EU) at LM. This paper outlines the overall test approach, summarizes the test results from the ASRG EU, describes the incorporation of those results into the test approach, and presents the results of applying the test approach to the ASC-1 #3 and #4 convertors. The test results include data from several accelerometers mounted on the convertors as well as the piston position and output power variables.

  4. Quantitative Analysis of Karst Conduit Structure Parameters and Hydraulic Parameters Based on Tracer Test

    NASA Astrophysics Data System (ADS)

    Qiang, Z.; Zhiqiang, Z.; Xu, M.; Jinyu, S.; Jihong, Q.

    2017-12-01

    The Old Town of Lijiang is famous as the world cultural heritage since 1997, while characterized by its ancient buildings and natural scenery, water is the soul of the town. Around Heilongtan Springs, there are a large quantity of springs at the Old Town of Lijiang , which is an important part of the World Cultural Heritage. Heilongtan Springs is 2420m above the sea level, the annual variation of the flow rate varies greatly (0 8042 x 104 m3 / year). Recharge area Jiuzihai depressions is 6km long, 3km wide and 2800m above sea level, as main karst water recharge area karst funnel and the sink hole are developing on this planation surface, in the research area medium to thick layers of limestone made up Beiya formation (T2b) of Triassic system distributed widely, karst is strongly developed and the fissure caves water occurrence. In order to exploring the application of tracer test in karst hydrogeology, a tracer test was conducted from Jiuzihai depressions to Ganze Spring. Based on the hydrogeological conditions in the study area, tracer test was used for analysis of groundwater connectivity and flow field characteristics, quantitative analysis of Tracer Breakthrough Curves (BTC) with code Qtracer2. The results demonstated that there are hydraulic connection between Jiuzihai depressions with Ganze Spring, and there are other karst conduits in this area. The longitudinal dispersivity coefficient is 0.24 m2/s, longitudinal dispersivity is 12.06m, flow-channel volume is 3.08×104 m3, flow-channel surface area is 3.27×107m2, mean diameter is 1.42m, Reynolds number is 25187, Froude number is 0.0061, respectively. The groundwater in this area is in a slow turbulent state. The results are of great significance to understand the law of groundwater migration, establish groundwater quality prediction model and exploit karst water resources effectively.

  5. The Effects of Humor on Test Anxiety and Test Performance

    ERIC Educational Resources Information Center

    Tali, Glenda

    2017-01-01

    Testing in an academic setting provokes anxiety in all students in higher education, particularly nursing students. When students experience high levels of anxiety, the resulting decline in test performance often does not represent an accurate assessment of students' academic achievement. This quantitative, experimental study examined the effects…

  6. 40 CFR 204.57-5 - Reporting of test results.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Reporting of test results. 204.57-5... of test results. (a)(1) The manufacturer shall submit a copy of the test report for all testing... compressor. (iii) Compressor serial number. (iv) Test results by serial numbers (3) The first test report for...

  7. 40 CFR 204.57-5 - Reporting of test results.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Reporting of test results. 204.57-5... of test results. (a)(1) The manufacturer shall submit a copy of the test report for all testing... compressor. (iii) Compressor serial number. (iv) Test results by serial numbers (3) The first test report for...

  8. 40 CFR 204.57-5 - Reporting of test results.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Reporting of test results. 204.57-5... of test results. (a)(1) The manufacturer shall submit a copy of the test report for all testing... compressor. (iii) Compressor serial number. (iv) Test results by serial numbers (3) The first test report for...

  9. 40 CFR 204.57-5 - Reporting of test results.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Reporting of test results. 204.57-5... of test results. (a)(1) The manufacturer shall submit a copy of the test report for all testing... compressor. (iii) Compressor serial number. (iv) Test results by serial numbers (3) The first test report for...

  10. 40 CFR 204.57-5 - Reporting of test results.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Reporting of test results. 204.57-5... of test results. (a)(1) The manufacturer shall submit a copy of the test report for all testing... compressor. (iii) Compressor serial number. (iv) Test results by serial numbers (3) The first test report for...

  11. Drug and alcohol testing results : 1997 annual report

    DOT National Transportation Integrated Search

    1998-12-01

    The Drug and Alcohol Testing Results 1997 Annual Report is a compilation and analysis of mass transit drug and alcohol testing reported by transit systems in the United States during 1997. The report covers testing results for the following drug type...

  12. A multisite assessment of the quantitative capabilities of the Xpert MTB/RIF assay.

    PubMed

    Blakemore, Robert; Nabeta, Pamela; Davidow, Amy L; Vadwai, Viral; Tahirli, Rasim; Munsamy, Vanisha; Nicol, Mark; Jones, Martin; Persing, David H; Hillemann, Doris; Ruesch-Gerdes, Sabine; Leisegang, Felicity; Zamudio, Carlos; Rodrigues, Camilla; Boehme, Catharina C; Perkins, Mark D; Alland, David

    2011-11-01

    The Xpert MTB/RIF is an automated molecular test for Mycobacterium tuberculosis that estimates bacterial burden by measuring the threshold-cycle (Ct) of its M. tuberculosis-specific real-time polymerase chain reaction. Bacterial burden is an important biomarker for disease severity, infection control risk, and response to therapy. Evaluate bacterial load quantitation by Xpert MTB/RIF compared with conventional quantitative methods. Xpert MTB/RIF results were compared with smear-microscopy, semiquantiative solid culture, and time-to-detection in liquid culture for 741 patients and 2,008 samples tested in a multisite clinical trial. An internal control real-time polymerase chain reaction was evaluated for its ability to identify inaccurate quantitative Xpert MTB/RIF results. Assays with an internal control Ct greater than 34 were likely to be inaccurately quantitated; this represented 15% of M. tuberculosis-positive tests. Excluding these, decreasing M. tuberculosis Ct was associated with increasing smear microscopy grade for smears of concentrated sputum pellets (r(s) = -0.77) and directly from sputum (r(s) =-0.71). A Ct cutoff of approximately 27.7 best predicted smear-positive status. The association between M. tuberculosis Ct and time-to-detection in liquid culture (r(s) = 0.68) and semiquantitative colony counts (r(s) = -0.56) was weaker than smear. Tests of paired same-patient sputum showed that high viscosity sputum samples contained ×32 more M. tuberculosis than nonviscous samples. Comparisons between the grade of the acid-fast bacilli smear and Xpert MTB/RIF quantitative data across study sites enabled us to identify a site outlier in microscopy. Xpert MTB/RIF quantitation offers a new, standardized approach to measuring bacterial burden in the sputum of patients with tuberculosis.

  13. Mapping quantitative trait loci controlling milk production in dairy cattle by exploiting progeny testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Georges, M.; Nielsen, D.; Mackinnon, M.

    1995-02-01

    We have exploited {open_quotes}progeny testing{close_quotes} to map quantitative trait loci (QTL) underlying the genetic variation of milk production in a selected dairy cattle population. A total of 1,518 sires, with progeny tests based on the milking performances of >150,000 daughters jointly, was genotyped for 159 autosomal microsatellites bracketing 1645 centimorgan or approximately two thirds of the bovine genome. Using a maximum likelihood multilocus linkage analysis accounting for variance heterogeneity of the phenotypes, we identified five chromosomes giving very strong evidence (LOD score {ge} 3) for the presence of a QTL controlling milk production: chromosomes 1, 6, 9, 10 and 20.more » These findings demonstrate that loci with considerable effects on milk production are still segregating in highly selected populations and pave the way toward marker-assisted selection in dairy cattle breeding. 44 refs., 4 figs., 3 tabs.« less

  14. A unified theory of impact crises and mass extinctions: quantitative tests.

    PubMed

    Rampino, M R; Haggerty, B M; Pagano, T C

    1997-05-30

    Several quantitative tests of a general hypothesis linking impacts of large asteroids and comets with mass extinctions of life are possible based on astronomical data, impact dynamics, and geological information. The waiting times of large-body impacts on the Earth derived from the flux of Earth-crossing asteroids and comets, and the estimated size of impacts capable of causing, large-scale environmental disasters, predict the impacts of objects > or = 5 km in diameter (> or = 10(7) Mt TNT equivalent) could be sufficient to explain the record of approximately 25 extinction pulses in the last 540 Myr, with the 5 recorded major mass extinctions related to impacts of the largest objects of > or = 10 km in diameter (> or = 10(8) Mt events). Smaller impacts (approximately 10(6) Mt), with significant regional environmental effects, could be responsible for the lesser boundaries in the geologic record. Tests of the "kill curve" relationship for impact-induced extinctions based on new data on extinction intensities, and several well-dated large impact craters, also suggest that major mass extinctions require large impacts, and that a step in the kill curve may exist at impacts that produce craters of approximately 100 km diameter, smaller impacts being capable of only relatively weak extinction pulses. Single impact craters less than approximately 60 km in diameter should not be associated with detectable global extinction pulses (although they may explain stage and zone boundaries marked by lesser faunal turnover), but multiple impacts in that size range may produce significant stepped extinction pulses. Statistical tests of the last occurrences of species at mass-extinction boundaries are generally consistent with predictions for abrupt or stepped extinctions, and several boundaries are known to show "catastrophic" signatures of environmental disasters and biomass crash, impoverished postextinction fauna and flora dominated by stress-tolerant and opportunistic species

  15. NEXT Single String Integration Test Results

    NASA Technical Reports Server (NTRS)

    Soulas, George C.; Patterson, Michael J.; Pinero, Luis; Herman, Daniel A.; Snyder, Steven John

    2010-01-01

    As a critical part of NASA's Evolutionary Xenon Thruster (NEXT) test validation process, a single string integration test was performed on the NEXT ion propulsion system. The objectives of this test were to verify that an integrated system of major NEXT ion propulsion system elements meets project requirements, to demonstrate that the integrated system is functional across the entire power processor and xenon propellant management system input ranges, and to demonstrate to potential users that the NEXT propulsion system is ready for transition to flight. Propulsion system elements included in this system integration test were an engineering model ion thruster, an engineering model propellant management system, an engineering model power processor unit, and a digital control interface unit simulator that acted as a test console. Project requirements that were verified during this system integration test included individual element requirements ; integrated system requirements, and fault handling. This paper will present the results of these tests, which include: integrated ion propulsion system demonstrations of performance, functionality and fault handling; a thruster re-performance acceptance test to establish baseline performance: a risk-reduction PMS-thruster integration test: and propellant management system calibration checks.

  16. 42 CFR 493.1281 - Standard: Comparison of test results.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 5 2012-10-01 2012-10-01 false Standard: Comparison of test results. 493.1281... Testing Analytic Systems § 493.1281 Standard: Comparison of test results. (a) If a laboratory performs the... between test results using the different methodologies, instruments, or testing sites. (b) The laboratory...

  17. 42 CFR 493.1281 - Standard: Comparison of test results.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Comparison of test results. 493.1281... Testing Analytic Systems § 493.1281 Standard: Comparison of test results. (a) If a laboratory performs the... between test results using the different methodologies, instruments, or testing sites. (b) The laboratory...

  18. 42 CFR 493.1281 - Standard: Comparison of test results.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 5 2013-10-01 2013-10-01 false Standard: Comparison of test results. 493.1281... Testing Analytic Systems § 493.1281 Standard: Comparison of test results. (a) If a laboratory performs the... between test results using the different methodologies, instruments, or testing sites. (b) The laboratory...

  19. 42 CFR 493.1281 - Standard: Comparison of test results.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Standard: Comparison of test results. 493.1281... Testing Analytic Systems § 493.1281 Standard: Comparison of test results. (a) If a laboratory performs the... between test results using the different methodologies, instruments, or testing sites. (b) The laboratory...

  20. 42 CFR 493.1281 - Standard: Comparison of test results.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 5 2014-10-01 2014-10-01 false Standard: Comparison of test results. 493.1281... Testing Analytic Systems § 493.1281 Standard: Comparison of test results. (a) If a laboratory performs the... between test results using the different methodologies, instruments, or testing sites. (b) The laboratory...

  1. 49 CFR 229.313 - Product testing results and records.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Product testing results and records. 229.313....313 Product testing results and records. (a) Results of product testing conducted by a railroad as... by this subpart. Results of product testing conducted by a vendor or private equipment owner in...

  2. 49 CFR 229.313 - Product testing results and records.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Product testing results and records. 229.313....313 Product testing results and records. (a) Results of product testing conducted by a railroad as... by this subpart. Results of product testing conducted by a vendor or private equipment owner in...

  3. 49 CFR 229.313 - Product testing results and records.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Product testing results and records. 229.313....313 Product testing results and records. (a) Results of product testing conducted by a railroad as... by this subpart. Results of product testing conducted by a vendor or private equipment owner in...

  4. MUC-4 Test Results and Analysis

    DTIC Science & Technology

    1992-01-01

    PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 MUC3 MUC4 STEMS 15,285 INFLECTED FORMS 14,56 1 TOTALS est at 10,000...34 . As an indication of system development during MUC4 , we can compare our TST3 results with our results on th e MUC-4 interim test (TST2) . The relevant... MUC4 Interim Test) Summary Scores SLOT POS ACT COR PAR INC ICR IPA SPU MIS NON REC PRE OVG inc-total 529 1189 160 63 24 0 23 942 282 718 36 16 79 perp

  5. Repeatability of quantitative sensory testing in healthy cats in a clinical setting with comparison to cats with osteoarthritis.

    PubMed

    Addison, Elena S; Clements, Dylan N

    2017-12-01

    Objectives The aim of this study was to evaluate the repeatability of quantitative sensory tests (QSTs) in a group of healthy untrained cats (n = 14) and to compare the results with those from cats with osteoarthritis (n = 7). Methods Peak vertical force (PVF) and vertical impulse were measured on a pressure plate system. Thermal sensitivity was assessed using a temperature-controlled plate at 7°C and 40°C. Individual paw lifts and overall duration of paw lifts were counted and measured for each limb. Paw withdrawal thresholds were measured using manual and electronic von Frey monofilaments (MVF and EVF, respectively) applied to the metacarpal or metatarsal pads. All measurements were repeated twice to assess repeatability of the tests. Results In healthy cats all tests were moderately repeatable. When compared with cats with osteoarthritis the PVF was significantly higher in healthy hindlimbs in repeat 1 but not in repeat 2. Cats with osteoarthritis of the forelimbs showed a decrease in the frequency of paw lifts on the 7°C plate compared with cats with healthy forelimbs, and the duration of paw lifts was significantly less than healthy forelimbs in the first repeat but not in the second repeat. Osteoarthritic limbs had significantly lower paw withdrawal thresholds with both MVF and EVF than healthy limbs. Conclusions and relevance QSTs are moderately repeatable in untrained cats. Kinetic gait analysis did not permit differentiation between healthy limbs and those with osteoarthritis, but thermal sensitivity testing (cold) does. Sensory threshold testing can differentiate osteoarthritic and healthy limbs, and may be useful in the diagnosis and monitoring of this condition in cats in the clinical setting.

  6. 49 CFR 234.273 - Results of inspections and tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Results of inspections and tests. 234.273 Section... Maintenance, Inspection, and Testing Inspections and Tests § 234.273 Results of inspections and tests. (a) Results of inspections and tests made in compliance with this part shall be recorded on forms provided by...

  7. 49 CFR 234.273 - Results of inspections and tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Results of inspections and tests. 234.273 Section... Maintenance, Inspection, and Testing Inspections and Tests § 234.273 Results of inspections and tests. (a) Results of inspections and tests made in compliance with this part shall be recorded on forms provided by...

  8. Phase III Simplified Integrated Test (SIT) results - Space Station ECLSS testing

    NASA Technical Reports Server (NTRS)

    Roberts, Barry C.; Carrasquillo, Robyn L.; Dubiel, Melissa Y.; Ogle, Kathryn Y.; Perry, Jay L.; Whitley, Ken M.

    1990-01-01

    During 1989, phase III testing of Space Station Freedom Environmental Control and Life Support Systems (ECLSS) began at Marshall Space Flight Center (MSFC) with the Simplified Integrated Test. This test, conducted at the MSFC Core Module Integration Facility (CMIF), was the first time the four baseline air revitalization subsystems were integrated together. This paper details the results and lessons learned from the phase III SIT. Future plans for testing at the MSFC CMIF are also discussed.

  9. A general way for quantitative magnetic measurement by transmitted electrons

    NASA Astrophysics Data System (ADS)

    Song, Dongsheng; Li, Gen; Cai, Jianwang; Zhu, Jing

    2016-01-01

    EMCD (electron magnetic circular dichroism) technique opens a new door to explore magnetic properties by transmitted electrons. The recently developed site-specific EMCD technique makes it possible to obtain rich magnetic information from the Fe atoms sited at nonequivalent crystallographic planes in NiFe2O4, however it is based on a critical demand for the crystallographic structure of the testing sample. Here, we have further improved and tested the method for quantitative site-specific magnetic measurement applicable for more complex crystallographic structure by using the effective dynamical diffraction effects (general routine for selecting proper diffraction conditions, making use of the asymmetry of dynamical diffraction for design of experimental geometry and quantitative measurement, etc), and taken yttrium iron garnet (Y3Fe5O12, YIG) with more complex crystallographic structure as an example to demonstrate its applicability. As a result, the intrinsic magnetic circular dichroism signals, spin and orbital magnetic moment of iron with site-specific are quantitatively determined. The method will further promote the development of quantitative magnetic measurement with high spatial resolution by transmitted electrons.

  10. 78 FR 64202 - Quantitative Messaging Research

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-28

    ... COMMODITY FUTURES TRADING COMMISSION Quantitative Messaging Research AGENCY: Commodity Futures... survey will follow qualitative message testing research (for which CFTC received fast- track OMB approval... comments. Please submit your comments using only one method and identify that it is for the ``Quantitative...

  11. Information needs of mothers regarding communicating BRCA1/2 cancer genetic test results to their children.

    PubMed

    Tercyak, Kenneth P; Peshkin, Beth N; Demarco, Tiffani A; Patenaude, Andrea Farkas; Schneider, Katherine A; Garber, Judy E; Valdimarsdottir, Heiddis B; Schwartz, Marc D

    2007-01-01

    Mothers who participate in genetic testing for hereditary breast/ovarian cancer risk must decide if, when, and how to ultimately share their BRCA1 and BRCA2 (BRCA1/2) test results with their minor-age children. One of the primary aides for mothers in making this decision is cancer genetic counseling. However, counseling is limited in how well it can educate mothers about such decisions without the availability of resources that are specific to family communication and genetic testing per se. In an effort to fill this gap and identify mothers most likely to benefit from such resources, surveys were conducted with 187 mothers undergoing BRCA1/2 testing who had children 8-21 years old. Data were collected weeks after genetic testing but prior to mothers' learning of their test results; quantitative assessments of informational resource needs (i.e., speaking with previous BRCA1/2 testing participants who are parents regarding their experiences, reading educational literature about options and what to expect, speaking with a family counselor, attending a family support group, and self-nominated other resources), testing motivations, decision making vigilance, and decisional conflict regarding communicating test results to children were included. Mothers' most-to-least frequently cited information resource needs were: literature (93.4%), family counseling (85.8%), prior participants (79.0%), support groups (53.9%), and other (28.9%; e.g., pediatricians and psychologists). Seventy-eight percent of mothers were interested in accessing three or more resources. In multivariate regression analyses, testing motivations (beta = 0.35, p = 0.03), decision-making vigilance (beta = 0.16, p = 0.00), and decisional conflict (beta = 0.10, p = 0.00) were associated with mothers' need level; mothers with a greater interest in testing to learn about their children's risks, those with more vigilant decision-making styles, and those with higher decisional conflict had the greatest need. In

  12. 12 CFR 252.147 - Reports of stress test results.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 12 Banks and Banking 4 2014-01-01 2014-01-01 false Reports of stress test results. 252.147 Section... Covered Companies § 252.147 Reports of stress test results. (a) Reports to the Board of stress test results. (1) A covered company must report the results of the stress test required under § 252.144 to the...

  13. 12 CFR 252.147 - Reports of stress test results.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 12 Banks and Banking 4 2013-01-01 2013-01-01 false Reports of stress test results. 252.147 Section... Covered Companies § 252.147 Reports of stress test results. (a) Reports to the Board of stress test results. (1) A covered company must report the results of the stress test required under section 252.144...

  14. Cryogenic Test Results of Hextek Mirror

    NASA Technical Reports Server (NTRS)

    Hadaway, James; Stahl, H. Philip; Eng, Ron; Hogue, William

    2004-01-01

    A 250 mm diameter lightweight borosilicate mirror has been interferometrically tested from room-temperature down to 30 K at the X-Ray Calibration Facility (XRCF) at Marshall Space Flight Center (MSFC). The minor blank was manufactured by Hextek Corporation using a high-temperature gas fusion process and was then polished at MSFC. It is a sandwich-type mirror consisting of a thin face-sheet (approx.1.5 mm thick), a core structure (20 mm thick, approx.43 mm diameter cells, & 0.5-1.2 mm thick walls), and a thin back-sheet (3 mm thick). The mirror has a 2500 mm spherical radius-of- curvature @/lo). The areal density is 14 kg/sq m. The mirror was tested in the 1 m x 2 m chamber using an Instantaneous Phase Interferometer (PI) from ADE Phase Shift Technologies. The mirror was tested twice. The first test measured the change in surface figure from ambient to 30 K and the repeatability of the change. An attempt was then made by QED Technologies to cryo-figure the mirror using magnetorheological finishing. The second test measured the effectiveness of the cryo- figuring. This paper will describe the test goals, the test instrumentation, and the test results for these cryogenic tests.

  15. Quantitative metal magnetic memory reliability modeling for welded joints

    NASA Astrophysics Data System (ADS)

    Xing, Haiyan; Dang, Yongbin; Wang, Ben; Leng, Jiancheng

    2016-03-01

    Metal magnetic memory(MMM) testing has been widely used to detect welded joints. However, load levels, environmental magnetic field, and measurement noises make the MMM data dispersive and bring difficulty to quantitative evaluation. In order to promote the development of quantitative MMM reliability assessment, a new MMM model is presented for welded joints. Steel Q235 welded specimens are tested along the longitudinal and horizontal lines by TSC-2M-8 instrument in the tensile fatigue experiments. The X-ray testing is carried out synchronously to verify the MMM results. It is found that MMM testing can detect the hidden crack earlier than X-ray testing. Moreover, the MMM gradient vector sum K vs is sensitive to the damage degree, especially at early and hidden damage stages. Considering the dispersion of MMM data, the K vs statistical law is investigated, which shows that K vs obeys Gaussian distribution. So K vs is the suitable MMM parameter to establish reliability model of welded joints. At last, the original quantitative MMM reliability model is first presented based on the improved stress strength interference theory. It is shown that the reliability degree R gradually decreases with the decreasing of the residual life ratio T, and the maximal error between prediction reliability degree R 1 and verification reliability degree R 2 is 9.15%. This presented method provides a novel tool of reliability testing and evaluating in practical engineering for welded joints.

  16. Drug and alcohol testing results 1998 annual report

    DOT National Transportation Integrated Search

    1999-12-01

    The Drug and Alcohol Testing Results 1998 Annual Report is a compilation and analysis of drug and alcohol testing results reported by transit systems in the United States during 1998. The report covers results for the following drug types: marijuana ...

  17. Drug and alcohol testing results 2000 annual report

    DOT National Transportation Integrated Search

    2001-12-01

    The Drug and Alcohol Testing Results 2000 Annual Report is a compilation and analysis of drug and alcohol testing results reported by transit systems in the United State during 2000. The report covers results for the following drug types: marijuana (...

  18. Drug and alcohol testing results 1999 annual report

    DOT National Transportation Integrated Search

    2000-12-01

    The Drug and Alcohol Testing Results 1999 Annual Report is a compilation and analysis of drug and alcohol testing results reported by transit systems in the United States during 1999. The report covers results for the following drug types: marijuana ...

  19. A quantitative investigation of the fracture pump-in/flowback test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Plahn, S.V.; Nolte, K.G.; Thompson, L.G.

    1997-02-01

    Fracture-closure pressure is an important parameter for fracture treatment design and evaluation. The pump-in/flowback (PIFB) test is frequently used to estimate its magnitude. The test is attractive because bottomhole pressures (BHP`s) during flowback develop a distinct and repeatable signature. This is in contrast to the pump-in/shut-in test, where strong indications of fracture closure are rarely seen. Various techniques are used to extract closure pressure from the flowback-pressure response. Unfortunately, these techniques give different estimates for closure pressure, and their theoretical bases are not well established. The authors present results that place the PIFB test on a firmer foundation. A numericalmore » model is used to simulate the PIFB test and glean physical mechanisms contributing to the response. On the basis of their simulation results, they propose interpretation techniques that give better estimates of closure pressure than existing techniques.« less

  20. A quantitative investigation of the fracture pump-in/flowback test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Plahn, S.V.; Nolte, K.G.; Miska, S.

    1995-12-31

    Fracture closure pressure is an important parameter for fracture treatment design and evaluation. The pump-in/flowback (PIFB) test is frequently used to estimate its magnitude. The test is attractive because bottomhole pressures during flowback develop a distinct and repeatable signature. This is in contrast to the pump-in/shut-in test where strong indications of fracture closure are rarely seen. Various techniques exist for extracting closure pressure from the flowback pressure response. Unfortunately, these procedures give different estimates for closure pressure and their theoretical bases are not well established. We present results that place the PIFB test on a more solid foundation. A numericalmore » model is used to simulate the PIFB test and glean physical mechanisms contributing to the response. Based on our simulation results, we propose an interpretation procedure which gives better estimates for closure pressure than existing techniques.« less

  1. Quantitative cell biology: the essential role of theory.

    PubMed

    Howard, Jonathon

    2014-11-05

    Quantitative biology is a hot area, as evidenced by the recent establishment of institutes, graduate programs, and conferences with that name. But what is quantitative biology? What should it be? And how can it contribute to solving the big questions in biology? The past decade has seen very rapid development of quantitative experimental techniques, especially at the single-molecule and single-cell levels. In this essay, I argue that quantitative biology is much more than just the quantitation of these experimental results. Instead, it should be the application of the scientific method by which measurement is directed toward testing theories. In this view, quantitative biology is the recognition that theory and models play critical roles in biology, as they do in physics and engineering. By tying together experiment and theory, quantitative biology promises a deeper understanding of underlying mechanisms, when the theory works, or to new discoveries, when it does not. © 2014 Howard. This article is distributed by The American Society for Cell Biology under license from the author(s). Two months after publication it is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).

  2. GOES Type III Loop Heat Pipe Life Test Results

    NASA Technical Reports Server (NTRS)

    Ottenstein, Laura

    2011-01-01

    The GOES Type III Loop Heat Pipe (LHP) was built as a life test unit for the loop heat pipes on the GOES N-Q series satellites. This propylene LHP was built by Dynatherm Corporation in 2000 and tested continuously for approximately 14 months. It was then put into storage for 3 years. Following the storage period, the LHP was tested at Swales Aerospace to verify that the loop performance hadn t changed. Most test results were consistent with earlier results. At the conclusion of testing at Swales, the LHP was transferred to NASA/GSFC for continued periodic testing. The LHP has been set up for testing in the Thermal Lab at GSFC since 2006. A group of tests consisting of start-ups, power cycles, and a heat transport limit test have been performed every six to nine months since March 2006. Tests results have shown no change in the loop performance over the five years of testing. This presentation will discuss the test hardware, test set-up, and tests performed. Test results to be presented include sample plots from individual tests, along with conductance measurements for all tests performed.

  3. Quantitative traits and diversification.

    PubMed

    FitzJohn, Richard G

    2010-12-01

    Quantitative traits have long been hypothesized to affect speciation and extinction rates. For example, smaller body size or increased specialization may be associated with increased rates of diversification. Here, I present a phylogenetic likelihood-based method (quantitative state speciation and extinction [QuaSSE]) that can be used to test such hypotheses using extant character distributions. This approach assumes that diversification follows a birth-death process where speciation and extinction rates may vary with one or more traits that evolve under a diffusion model. Speciation and extinction rates may be arbitrary functions of the character state, allowing much flexibility in testing models of trait-dependent diversification. I test the approach using simulated phylogenies and show that a known relationship between speciation and a quantitative character could be recovered in up to 80% of the cases on large trees (500 species). Consistent with other approaches, detecting shifts in diversification due to differences in extinction rates was harder than when due to differences in speciation rates. Finally, I demonstrate the application of QuaSSE to investigate the correlation between body size and diversification in primates, concluding that clade-specific differences in diversification may be more important than size-dependent diversification in shaping the patterns of diversity within this group.

  4. 7 CFR 91.24 - Reports of test results.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Reports of test results. 91.24 Section 91.24... SERVICES AND GENERAL INFORMATION Reporting § 91.24 Reports of test results. (a) Results of analyses are... may call the appropriate Science and Technology laboratory for interim or final results prior to...

  5. 49 CFR 199.229 - Reporting of alcohol testing results.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Reporting of alcohol testing results. 199.229... ALCOHOL TESTING Alcohol Misuse Prevention Program § 199.229 Reporting of alcohol testing results. (a) Each... alcohol testing results using the Management Information System (MIS) form and instructions as required by...

  6. 49 CFR 199.229 - Reporting of alcohol testing results.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Reporting of alcohol testing results. 199.229... ALCOHOL TESTING Alcohol Misuse Prevention Program § 199.229 Reporting of alcohol testing results. (a) Each... alcohol testing results using the Management Information System (MIS) form and instructions as required by...

  7. 49 CFR 199.229 - Reporting of alcohol testing results.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Reporting of alcohol testing results. 199.229... ALCOHOL TESTING Alcohol Misuse Prevention Program § 199.229 Reporting of alcohol testing results. (a) Each... alcohol testing results using the Management Information System (MIS) form and instructions as required by...

  8. 49 CFR 199.229 - Reporting of alcohol testing results.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Reporting of alcohol testing results. 199.229... ALCOHOL TESTING Alcohol Misuse Prevention Program § 199.229 Reporting of alcohol testing results. (a) Each... alcohol testing results using the Management Information System (MIS) form and instructions as required by...

  9. 49 CFR 199.229 - Reporting of alcohol testing results.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Reporting of alcohol testing results. 199.229... ALCOHOL TESTING Alcohol Misuse Prevention Program § 199.229 Reporting of alcohol testing results. (a) Each... alcohol testing results using the Management Information System (MIS) form and instructions as required by...

  10. [Significance of test results in drug hypersensitivity].

    PubMed

    Wozniak, K D

    1977-12-15

    For the diagnostics of allergic drug reactions in 2,246 patients tests of the skin and in vitro tests were carried out. As causes of the drug rashes analgetics/antipyretics, antibiotics, sulfonamides, local anaesthetics, oral anticonceptive drugs, remedies for the circulation, psychopharmaca and many others have been established. In these cases by means of skin test in 81.5%, by means of the lymphocyte transformation test in 42.9% and by means of the migration inhibition test in 35.9% of the patients a concordant result could be achieved concerning the clinical course of the disease. Relevant to practice from the results must be derived that in sensibilisation proved the avoidance of the pharmacon and of immunochemical related substances is necessary as well as principally in every anamnesis the question for drug tolerances must be asked. The possibility of the development of side effects of pharmaca when these facts are not taken into consideration is emphasized with the help of examples.

  11. Sweat testing to evaluate autonomic function

    PubMed Central

    Illigens, Ben M.W.; Gibbons, Christopher H.

    2011-01-01

    Sudomotor dysfunction is one of the earliest detectable neurophysiologic abnormalities in distal small fiber neuropathy. Traditional neurophysiologic measurements of sudomotor function include thermoregulatory sweat testing (TST), quantitative sudomotor axon reflex testing (QSART), silicone impressions, the sympathetic skin response (SSR), and the recent addition of quantitative direct and indirect axon reflex testing (QDIRT). These testing techniques, when used in combination, can detect and localized pre- and postganglionic lesions, can provide early diagnosis of sudomotor dysfunction and can monitor disease progression or disease recovery. In this article, we review the common tests available for assessment of sudomotor function, detail the testing methodology, review the limitations and provide examples of test results. PMID:18989618

  12. 7 CFR 91.24 - Reports of test results.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Reports of test results. 91.24 Section 91.24... SERVICES AND GENERAL INFORMATION Reporting § 91.24 Reports of test results. (a) Results of analyses are provided, in writing, by facsimile, by e-mail or other electronic means to the applicant. (b) Results of...

  13. 7 CFR 91.24 - Reports of test results.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Reports of test results. 91.24 Section 91.24... SERVICES AND GENERAL INFORMATION Reporting § 91.24 Reports of test results. (a) Results of analyses are provided, in writing, by facsimile, by e-mail or other electronic means to the applicant. (b) Results of...

  14. 7 CFR 91.24 - Reports of test results.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Reports of test results. 91.24 Section 91.24... SERVICES AND GENERAL INFORMATION Reporting § 91.24 Reports of test results. (a) Results of analyses are provided, in writing, by facsimile, by e-mail or other electronic means to the applicant. (b) Results of...

  15. 7 CFR 91.24 - Reports of test results.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Reports of test results. 91.24 Section 91.24... SERVICES AND GENERAL INFORMATION Reporting § 91.24 Reports of test results. (a) Results of analyses are provided, in writing, by facsimile, by e-mail or other electronic means to the applicant. (b) Results of...

  16. 12 CFR 252.156 - Reports of stress test results.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 12 Banks and Banking 4 2013-01-01 2013-01-01 false Reports of stress test results. 252.156 Section....156 Reports of stress test results. (a) Reports to the Board of stress test results—(1) Savings and... report the results of the stress test to the Board by January 5 of each calendar year in the manner and...

  17. I Vivo Quantitative Ultrasound Imaging and Scatter Assessments.

    NASA Astrophysics Data System (ADS)

    Lu, Zheng Feng

    There is evidence that "instrument independent" measurements of ultrasonic scattering properties would provide useful diagnostic information that is not available with conventional ultrasound imaging. This dissertation is a continuing effort to test the above hypothesis and to incorporate quantitative ultrasound methods into clinical examinations for early detection of diffuse liver disease. A well-established reference phantom method was employed to construct quantitative ultrasound images of tissue in vivo. The method was verified by extensive phantom tests. A new method was developed to measure the effective attenuation coefficient of the body wall. The method relates the slope of the difference between the echo signal power spectrum from a uniform region distal to the body wall and the echo signal power spectrum from a reference phantom to the body wall attenuation. The accuracy obtained from phantom tests suggests further studies with animal experiments. Clinically, thirty-five healthy subjects and sixteen patients with diffuse liver disease were studied by these quantitative ultrasound methods. The average attenuation coefficient in normals agreed with previous investigators' results; in vivo backscatter coefficients agreed with the results from normals measured by O'Donnell. Strong discriminating power (p < 0.001) was found for both attenuation and backscatter coefficients between fatty livers and normals; a significant difference (p < 0.01) was observed in the backscatter coefficient but not in the attenuation coefficient between cirrhotic livers and normals. An in vivo animal model of steroid hepatopathy was used to investigate the system sensitivity in detecting early changes in canine liver resulting from corticosteroid administration. The average attenuation coefficient slope increased from 0.7 dB/cm/MHz in controls to 0.82 dB/cm/MHz (at 6 MHz) in treated animals on day 14 into the treatment, and the backscatter coefficient was 26times 10^{ -4}cm^{-1}sr

  18. Quantitative transmission Raman spectroscopy of pharmaceutical tablets and capsules.

    PubMed

    Johansson, Jonas; Sparén, Anders; Svensson, Olof; Folestad, Staffan; Claybourn, Mike

    2007-11-01

    Quantitative analysis of pharmaceutical formulations using the new approach of transmission Raman spectroscopy has been investigated. For comparison, measurements were also made in conventional backscatter mode. The experimental setup consisted of a Raman probe-based spectrometer with 785 nm excitation for measurements in backscatter mode. In transmission mode the same system was used to detect the Raman scattered light, while an external diode laser of the same type was used as excitation source. Quantitative partial least squares models were developed for both measurement modes. The results for tablets show that the prediction error for an independent test set was lower for the transmission measurements with a relative root mean square error of about 2.2% as compared with 2.9% for the backscatter mode. Furthermore, the models were simpler in the transmission case, for which only a single partial least squares (PLS) component was required to explain the variation. The main reason for the improvement using the transmission mode is a more representative sampling of the tablets compared with the backscatter mode. Capsules containing mixtures of pharmaceutical powders were also assessed by transmission only. The quantitative results for the capsules' contents were good, with a prediction error of 3.6% w/w for an independent test set. The advantage of transmission Raman over backscatter Raman spectroscopy has been demonstrated for quantitative analysis of pharmaceutical formulations, and the prospects for reliable, lean calibrations for pharmaceutical analysis is discussed.

  19. Automated Chemical Warfare Respirator Quantitative Fit Test Instrument

    DTIC Science & Technology

    1985-04-01

    i requisite to assessment of the level of protection provided by the respirator. Quantitative measurement of the variability of fit of the face- plec ...ACQUISITION SYSTEM CORN OIL FILlE RESERVOIR -~ HEATER CONCENTRATIOA ZAONVU~C RB EAHG1FECO PHOTOMETER- STA RT CIL RESERVOIR BOTTGM TEMPERATURE SWITCH...30 .........-.-.-... % L4* . 3.3.4 HP 3497A Control and Data Acquisition Unit lI, "%a.infraoc" i.; a box with five slots for plug-in modules pll u; a

  20. Quantitative analysis of four EMG amplifiers.

    PubMed

    Perreault, E J; Hunter, I W; Kearney, R E

    1993-09-01

    Four typical EMG amplifiers were tested quantitatively to observe the diversity and specificity of available equipment. Gain, phase, common mode rejection ratio (CMRR) and noise characteristics were measured for each device. Various gain and phase responses were observed, each best suited to specific application areas. For all amplifiers, the CMRR was shown to decrease dramatically in the presence of input impedance mismatches of more than 10 k omega between the two electrodes. Because such impedance mismatches are common on the skin surface, these results indicate that proper skin preparation is required to maximize the noise rejection capabilities of the tested amplifiers.

  1. The long-term reliability of static and dynamic quantitative sensory testing in healthy individuals.

    PubMed

    Marcuzzi, Anna; Wrigley, Paul J; Dean, Catherine M; Adams, Roger; Hush, Julia M

    2017-07-01

    Quantitative sensory tests (QSTs) have been increasingly used to investigate alterations in somatosensory function in a wide range of painful conditions. The interpretation of these findings is based on the assumption that the measures are stable and reproducible. To date, reliability of QST has been investigated for short test-retest intervals. The aim of this study was to investigate the long-term reliability of a multimodal QST assessment in healthy people, with testing conducted on 3 occasions over 4 months. Forty-two healthy people were enrolled in the study. Static and dynamic tests were performed, including cold and heat pain threshold (CPT, HPT), mechanical wind-up [wind-up ratio (WUR)], pressure pain threshold (PPT), 2-point discrimination (TPD), and conditioned pain modulation (CPM). Systematic bias, relative reliability and agreement were analysed using repeated measure analysis of variance, intraclass correlation coefficients (ICCs3,1) and SE of the measurement (SEM), respectively. Static QST (CPT, HPT, PPT, and TPD) showed good-to-excellent reliability (ICCs: 0.68-0.90). Dynamic QST (WUR and CPM) showed poor-to-good reliability (ICCs: 0.35-0.61). A significant linear decrease over time was observed for mechanical QST at the back (PPT and TPD) and for CPM (P < 0.01). Static QST were stable over a period of 4 months; however, a small systematic decrease over time has been observed for mechanical QST. Dynamic QST showed considerable variability over time; in particular, CPM using PPT as the test stimulus did not show adequate reliability, suggesting that this test paradigm may be less useful for monitoring individuals over time.

  2. Temporary Thermocouple Attachment for Thermal/Vacuum Testing at Non-Extreme Temperatures - Test Results

    NASA Technical Reports Server (NTRS)

    Wright, Sarah E.; Ungar, Eugene K.

    2017-01-01

    Post-test examination and data analysis that followed a two week long vacuum test showed that numerous self-stick thermocouples became detached from the test article. The thermocouples were reattached with thermally conductive epoxy and the test was repeated to obtain the required data. Because the thermocouple detachment resulted in significant expense and rework, it was decided to investigate the temporary attachment methods used around NASA and to perform a test to assess their efficacy. The present work describes the testing that was performed in early and mid-2017. The test article and the temporary thermocouple attachment methods tested are described. During the first test, fully half of the thermocouples detached - although the detachment showed subtly in the data for some. The second test was performed to confirm the data from the first test and to investigate the effect of test article and thermocouple grounding. The results of the testing over temperatures ranging from -150 to 200degF are detailed and preliminary recommendations are made for temporary thermocouple attachment methods.

  3. Examining the Role of Numeracy in College STEM Courses: Results from the Quantitative Reasoning for College Science (QuaRCS) Assessment Instrument

    NASA Astrophysics Data System (ADS)

    Follette, Katherine B.; McCarthy, Donald W.; Dokter, Erin F.; Buxner, Sanlyn; Prather, Edward E.

    2016-01-01

    Is quantitative literacy a prerequisite for science literacy? Can students become discerning voters, savvy consumers and educated citizens without it? Should college science courses for nonmajors be focused on "science appreciation", or should they engage students in the messy quantitative realities of modern science? We will present results from the recently developed and validated Quantitative Reasoning for College Science (QuaRCS) Assessment, which probes both quantitative reasoning skills and attitudes toward mathematics. Based on data from nearly two thousand students enrolled in nineteen general education science courses, we show that students in these courses did not demonstrate significant skill or attitude improvements over the course of a single semester, but find encouraging evidence for longer term trends.

  4. Quantitative traits for the tail suspension test: automation, optimization, and BXD RI mapping.

    PubMed

    Lad, Heena V; Liu, Lin; Payá-Cano, José L; Fernandes, Cathy; Schalkwyk, Leonard C

    2007-07-01

    Immobility in the tail suspension test (TST) is considered a model of despair in a stressful situation, and acute treatment with antidepressants reduces immobility. Inbred strains of mouse exhibit widely differing baseline levels of immobility in the TST and several quantitative trait loci (QTLs) have been nominated. The labor of manual scoring and various scoring criteria make obtaining robust data and comparisons across different laboratories problematic. Several studies have validated strain gauge and video analysis methods by comparison with manual scoring. We set out to find objective criteria for automated scoring parameters that maximize the biological information obtained, using a video tracking system on tapes of tail suspension tests of 24 lines of the BXD recombinant inbred panel and the progenitor strains C57BL/6J and DBA/2J. The maximum genetic effect size is captured using the highest time resolution and a low mobility threshold. Dissecting the trait further by comparing genetic association of multiple measures reveals good evidence for loci involved in immobility on chromosomes 4 and 15. These are best seen when using a high threshold for immobility, despite the overall better heritability at the lower threshold. A second trial of the test has greater duration of immobility and a completely different genetic profile. Frequency of mobility is also an independent phenotype, with a distal chromosome 1 locus.

  5. Ethnic differences in oro-facial somatosensory profiles-quantitative sensory testing in Chinese and Danes.

    PubMed

    Yang, G; Luo, Y; Baad-Hansen, L; Wang, K; Arendt-Nielsen, L; Xie, Q-F; Svensson, P

    2013-11-01

    Ethnic differences in pain experiences have been widely assessed in various pathological and experimental conditions. However, limited sensory modalities have been described in previous research, and the affective-motivational factors have so far been estimated to be the main mediator for the ethnic differences. This study aimed to detect the ethnic differences of oro-facial somatosensory profiles related to the sensory-discriminative dimension in healthy volunteers. The standardised quantitative sensory testing battery developed by the German Research Network on Neuropathic Pain was performed bilaterally in the infraorbital and mental regions on age- and gender-matched healthy Chinese and Danes, 29 participants each group. The influences of ethnicity, gender and test site on the somatosensory profile were evaluated by three-way anova. The ethnic disparities were also presented by Z-scores. Compared to Danes, Chinese were more sensitive to thermal detection, thermal pain, mechanical deep pain and mechanical pain rating parameters (P < 0·002) related to small fibre functions. However, the inverse results were observed for mechanical tactile modality related to large fibre function (P < 0·001) and wind-up ratio (P = 0·006). Women presented higher sensitivity compared to men. The mean Z-scores of all the parameters from Chinese group were in the normal zone created by Danish Caucasians' means and SDs. The ethnic disparities in somatosensory profile illustrated the necessity of establishing the reference data for different ethnic groups and possibly individual pain management strategies for the different ethnic groups. © 2013 John Wiley & Sons Ltd.

  6. Cost-effectiveness analysis of a quantitative immunochemical test for colorectal cancer screening.

    PubMed

    Wilschut, Janneke A; Hol, Lieke; Dekker, Evelien; Jansen, Jan B; Van Leerdam, Monique E; Lansdorp-Vogelaar, Iris; Kuipers, Ernst J; Habbema, J Dik F; Van Ballegooijen, Marjolein

    2011-11-01

    Two European randomized trials (N = 30,000) compared guaiac fecal occult blood testing with quantitative fecal immunochemical testing (FIT) and showed better attendance rates and test characteristics for FIT. We aimed to identify the most cost-effective FIT cutoff level for referral to colonoscopy based on data from these trials and allowing for differences in screening ages. We used the validated MIcrosimulation SCreening ANalysis (MISCAN)-Colon microsimulation model to estimate costs and effects of different screening strategies for FIT cutoff levels of 50, 75, 100, 150, and 200 ng/mL hemoglobin. For each cutoff level, screening strategies were assessed with various age ranges and screening intervals. We assumed sufficient colonoscopy capacity for all strategies. At all cost levels, FIT screening was most effective with the 50 ng/mL cutoff level. The incremental cost-effectiveness ratio of biennial screening between ages 55 and 75 years using FIT at 50 ng/mL, for example, was 3900 euro per life year gained. Annual screening had an incremental cost-effectiveness ratio of 14,900 euro per life year gained, in combination with a wider age range (between ages 45 and 80 years). In the sensitivity analysis, 50 ng/mL remained the preferred cutoff level. FIT screening is more cost-effective at a cutoff level of 50 ng/mL than at higher cutoff levels. This supports the recommendation to use FIT at a cutoff level of 50 ng/mL, which is considerably lower than the values used in current practice. Copyright © 2011 AGA Institute. Published by Elsevier Inc. All rights reserved.

  7. Shake Test Results and Dynamic Calibration Efforts for the Large Rotor Test Apparatus

    NASA Technical Reports Server (NTRS)

    Russell, Carl R.

    2014-01-01

    Prior to the full-scale wind tunnel test of the UH-60A Airloads rotor, a shake test was completed on the Large Rotor Test Apparatus. The goal of the shake test was to characterize the oscillatory response of the test rig and provide a dynamic calibration of the balance to accurately measure vibratory hub loads. This paper provides a summary of the shake test results, including balance, shaft bending gauge, and accelerometer measurements. Sensitivity to hub mass and angle of attack were investigated during the shake test. Hub mass was found to have an important impact on the vibratory forces and moments measured at the balance, especially near the UH-60A 4/rev frequency. Comparisons were made between the accelerometer data and an existing finite-element model, showing agreement on mode shapes, but not on natural frequencies. Finally, the results of a simple dynamic calibration are presented, showing the effects of changes in hub mass. The results show that the shake test data can be used to correct in-plane loads measurements up to 10 Hz and normal loads up to 30 Hz.

  8. An adapted mindfulness-based stress reduction program for elders in a continuing care retirement community: quantitative and qualitative results from a pilot randomized controlled trial.

    PubMed

    Moss, Aleezé S; Reibel, Diane K; Greeson, Jeffrey M; Thapar, Anjali; Bubb, Rebecca; Salmon, Jacqueline; Newberg, Andrew B

    2015-06-01

    The purpose of this study was to test the feasibility and effectiveness of an adapted 8-week Mindfulness-Based Stress Reduction (MBSR) program for elders in a continuing care community. This mixed-methods study used both quantitative and qualitative measures. A randomized waitlist control design was used for the quantitative aspect of the study. Thirty-nine elderly were randomized to MBSR (n = 20) or a waitlist control group (n = 19), mean age was 82 years. Both groups completed pre-post measures of health-related quality of life, acceptance and psychological flexibility, facets of mindfulness, self-compassion, and psychological distress. A subset of MBSR participants completed qualitative interviews. MBSR participants showed significantly greater improvement in acceptance and psychological flexibility and in role limitations due to physical health. In the qualitative interviews, MBSR participants reported increased awareness, less judgment, and greater self-compassion. Study results demonstrate the feasibility and potential effectiveness of an adapted MBSR program in promoting mind-body health for elders. © The Author(s) 2014.

  9. Determining quantitative immunophenotypes and evaluating their implications

    NASA Astrophysics Data System (ADS)

    Redelman, Douglas; Hudig, Dorothy; Berner, Dave; Castell, Linda M.; Roberts, Don; Ensign, Wayne

    2002-05-01

    Quantitative immunophenotypes varied widely among > 100 healthy young males but were maintained at characteristic levels within individuals. The initial results (SPIE Proceedings 4260:226) that examined cell numbers and the quantitative expression of adhesion and lineage-specific molecules, e.g., CD2 and CD14, have now been confirmed and extended to include the quantitative expression of inducible molecules such as HLA-DR and perforin (Pf). Some properties, such as the ratio of T helper (Th) to T cytotoxic/suppressor (Tc/s) cells, are known to be genetically determined. Other properties, e.g., the T:B cell ratio, the amount of CD19 per B cell, etc., behaved similarly and may also be inherited traits. Since some patterns observed in these healthy individuals resembled those found in pathological situations we tested whether the patterns could be associated with the occurrence of disease. The current studies shows that there were associations between quantitative immunophenotypes and the subsequent incidence and severity of disease. For example, individuals with characteristically low levels of HLA-DR or B cells or reduced numbers of Pf+ Tc/s cells had more frequent and/or more severe upper respiratory infections. Quantitative immunophenotypes will be more widely measured if the necessary standards are available and if appropriate procedures are made more accessible.

  10. 49 CFR 199.109 - Review of drug testing results.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Review of drug testing results. 199.109 Section... MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.109 Review of drug testing results. (a) MRO appointment. Each operator shall...

  11. 49 CFR 199.109 - Review of drug testing results.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Review of drug testing results. 199.109 Section... MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.109 Review of drug testing results. (a) MRO appointment. Each operator shall...

  12. 49 CFR 199.109 - Review of drug testing results.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Review of drug testing results. 199.109 Section... MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.109 Review of drug testing results. (a) MRO appointment. Each operator shall...

  13. 49 CFR 199.109 - Review of drug testing results.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Review of drug testing results. 199.109 Section... MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.109 Review of drug testing results. (a) MRO appointment. Each operator shall...

  14. 49 CFR 199.109 - Review of drug testing results.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Review of drug testing results. 199.109 Section... MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.109 Review of drug testing results. (a) MRO appointment. Each operator shall...

  15. B-52 control configured vehicles: Flight test results

    NASA Technical Reports Server (NTRS)

    Arnold, J. I.; Murphy, F. B.

    1976-01-01

    Recently completed B-52 Control Configured Vehicles (CCV) flight testing is summarized, and results are compared to analytical predictions. Results are presented for five CCV system concepts: ride control, maneuver load control, flutter mode control, augmented stability, and fatigue reduction. Test results confirm analytical predictions and show that CCV system concepts achieve performance goals when operated individually or collectively.

  16. Module Hipot and ground continuity test results

    NASA Technical Reports Server (NTRS)

    Griffith, J. S.

    1984-01-01

    Hipot (high voltage potential) and module frame continuity tests of solar energy conversion modules intended for deployment into large arrays are discussed. The purpose of the tests is to reveal potentially hazardous voltage conditions in installed modules, and leakage currents that may result in loss of power or cause ground fault system problems, i.e., current leakage potential and leakage voltage distribution. The tests show a combined failure rate of 36% (69% when environmental testing is included). These failure rates are believed easily corrected by greater care in fabrication.

  17. Modernization of Physical Appearance and Solution Color Tests Using Quantitative Tristimulus Colorimetry: Advantages, Harmonization, and Validation Strategies.

    PubMed

    Pack, Brian W; Montgomery, Laura L; Hetrick, Evan M

    2015-10-01

    Color measurements, including physical appearance, are important yet often misunderstood and underappreciated aspects of a control strategy for drug substances and drug products. From a patient safety perspective, color can be an important control point for detecting contamination, impurities, and degradation products, with human visual acuity often more sensitive for colored impurities than instrumental techniques such as HPLC. Physical appearance tests and solution color tests can also serve an important role in ensuring that appropriate steps are taken such that clinical trials do not become unblinded when the active material is compared with another product or a placebo. Despite the importance of color tests, compendial visual tests are not harmonized across the major pharmacopoeias, which results in ambiguous specifications of little value, difficult communication of true sample color, and significant extra work required for global registration. Some pharmacopoeias have not yet recognized or adopted technical advances in the instrumental measurement of color and appearance, whereas others begin to acknowledge the advantage of instrumental colorimetry, yet leave implementation of the technology ambiguous. This commentary will highlight the above-mentioned inconsistencies, provide an avenue toward harmonization and modernization, and outline a scientifically sound approach for implementing quantitative technologies for improved measurement, communication, and control of color and appearance for both solutions and solids. Importantly, this manuscript, for the first time, outlines a color method validation approach that is consistent with the International Conference on Harmonization's guidance on the topic of method validation. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.

  18. What Do the Results of Genetic Tests Mean?

    MedlinePlus

    ... does it take to get the results? Will health insurance cover the costs of genetic testing? What are the benefits of genetic testing? What are the risks and limitations of genetic testing? What is genetic ...

  19. 12 CFR 252.156 - Reports of stress test results.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 12 Banks and Banking 4 2014-01-01 2014-01-01 false Reports of stress test results. 252.156 Section... SYSTEM (CONTINUED) ENHANCED PRUDENTIAL STANDARDS (REGULATION YY) Company-Run Stress Test Requirements for....156 Reports of stress test results. (a) Reports to the Board of stress test results—(1) Savings and...

  20. Results and analysis of the switchyard impact tests

    DOT National Transportation Integrated Search

    1980-01-01

    This report presents the results and analysis of series 3 through 7 and series 10 of the FRA/RPI/AAR Switchyard Impact Tests. The test results and analysis are used to evaluate the head shield and the shelf-E coupler as protective devices for hazardo...

  1. A bottom-up approach in estimating the measurement uncertainty and other important considerations for quantitative analyses in drug testing for horses.

    PubMed

    Leung, Gary N W; Ho, Emmie N M; Kwok, W Him; Leung, David K K; Tang, Francis P W; Wan, Terence S M; Wong, April S Y; Wong, Colton H F; Wong, Jenny K Y; Yu, Nola H

    2007-09-07

    Quantitative determination, particularly for threshold substances in biological samples, is much more demanding than qualitative identification. A proper assessment of any quantitative determination is the measurement uncertainty (MU) associated with the determined value. The International Standard ISO/IEC 17025, "General requirements for the competence of testing and calibration laboratories", has more prescriptive requirements on the MU than its superseded document, ISO/IEC Guide 25. Under the 2005 or 1999 versions of the new standard, an estimation of the MU is mandatory for all quantitative determinations. To comply with the new requirement, a protocol was established in the authors' laboratory in 2001. The protocol has since evolved based on our practical experience, and a refined version was adopted in 2004. This paper describes our approach in establishing the MU, as well as some other important considerations, for the quantification of threshold substances in biological samples as applied in the area of doping control for horses. The testing of threshold substances can be viewed as a compliance test (or testing to a specified limit). As such, it should only be necessary to establish the MU at the threshold level. The steps in a "Bottom-Up" approach adopted by us are similar to those described in the EURACHEM/CITAC guide, "Quantifying Uncertainty in Analytical Measurement". They involve first specifying the measurand, including the relationship between the measurand and the input quantities upon which it depends. This is followed by identifying all applicable uncertainty contributions using a "cause and effect" diagram. The magnitude of each uncertainty component is then calculated and converted to a standard uncertainty. A recovery study is also conducted to determine if the method bias is significant and whether a recovery (or correction) factor needs to be applied. All standard uncertainties with values greater than 30% of the largest one are then used to

  2. Preliminary test results from the CELSS Test Facility Engineering Development Unit

    NASA Technical Reports Server (NTRS)

    Kliss, Mark H.; Macelroy, R. D.; Blackwell, C. C.; Borchers, B. A.; Drews, M. E.; Longabaugh, J. R.; Yendler, B. S.; Zografos, A. I.

    1994-01-01

    As part of the NASA Controlled Ecological Life Support System (CELSS) Program, a CELSS Test Facility (CTF) is being planned for installation on the Space Station. The CTF will be used to provide data on the productivity and efficiency of a variety of CELSS higher plant crops grown in the microgravity environment of the Space Station. Tight environmental control will be maintained while data on gas exchange rates and biomass accumulation rates are collected. In order to obtain an early realistic determination of the subsystem and system requirements necessary to provide the environmental conditions specified for CTF crop productivity experiments, an Engineering Development Unit (EDU) has been designed, constructed and is in the process of subsystem and system testing at NASA Ames Research Center. The EDU is a ground test-bed which will be used to characterize the integrated performance of major subsystem technologies, to evaluate hardware candidates and control strategies required for the CTF, and to further define the ability to meet CTF requirements within present Space Station constraints. This paper reviews the functional requirements for the EDU, and focuses on the performance evaluation and test results of the various subsystems. Preliminary integrated performance results and control system operation are addressed, and plans for future science and technology testing are discussed.

  3. Hand-arm vibration syndrome: clinical characteristics, conventional electrophysiology and quantitative sensory testing.

    PubMed

    Rolke, Roman; Rolke, Silke; Vogt, Thomas; Birklein, Frank; Geber, Christian; Treede, Rolf-Detlef; Letzel, Stephan; Voelter-Mahlknecht, Susanne

    2013-08-01

    Workers exposed to vibrating tools may develop hand-arm vibration syndrome (HAVS). We assessed the somatosensory phenotype using quantitative sensory testing (QST) in comparison to electrophysiology to characterize (1) the most sensitive QST parameter for detecting sensory loss, (2) the correlation of QST and electrophysiology, and (3) the frequency of a carpal tunnel syndrome (CTS) in HAVS. QST, cold provocation tests, fine motor skills, and median nerve neurography were used. QST included thermal and mechanical detection and pain thresholds. Thirty-two patients were examined (54 ± 11 years, 91% men) at the more affected hand compared to 16 matched controls. Vibration detection threshold was the most sensitive parameter to detect sensory loss that was more pronounced in the sensitivity range of Pacinian (150 Hz, x12) than Meissner's corpuscles (20 Hz, x3). QST (84% abnormal) was more sensitive to detect neural dysfunction than conventional electrophysiology (37% abnormal). Motor (34%) and sensory neurography (25%) were abnormal in HAVS. CTS frequency was not increased (9.4%). Findings are consistent with a mechanically-induced, distally pronounced motor and sensory neuropathy independent of CTS. HAVS involves a neuropathy predominantly affecting large fibers with a sensory damage related to resonance frequencies of vibrating tools. Copyright © 2013 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  4. 12 CFR 325.207 - Publication of stress test results.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 12 Banks and Banking 5 2013-01-01 2013-01-01 false Publication of stress test results. 325.207... GENERAL POLICY CAPITAL MAINTENANCE Annual Stress Test § 325.207 Publication of stress test results. (a) Publication date. (1) A $10 billion to $50 billion covered bank must publish a summary of the results of its...

  5. 12 CFR 252.148 - Disclosure of stress test results.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 12 Banks and Banking 4 2013-01-01 2013-01-01 false Disclosure of stress test results. 252.148... Requirements for Covered Companies § 252.148 Disclosure of stress test results. (a) Public disclosure of results—(1) In general. (i) A covered company must disclose a summary of the results of the stress test...

  6. 12 CFR 325.207 - Publication of stress test results.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 12 Banks and Banking 5 2014-01-01 2014-01-01 false Publication of stress test results. 325.207... GENERAL POLICY CAPITAL MAINTENANCE Annual Stress Test § 325.207 Publication of stress test results. (a) Publication date. (1) A $10 billion to $50 billion covered bank must publish a summary of the results of its...

  7. The right not to know HIV-test results.

    PubMed

    Temmerman, M; Ndinya-Achola, J; Ambani, J; Piot, P

    1995-04-15

    Large numbers of pregnant women in Africa have been invited to participate in studies on HIV infection. Study protocols adhere to guidelines on voluntary participation after pre-test and post-test counselling and informed consent; nevertheless, women may consent because they have been asked to do so without fully understanding the implications of being tested for HIV. Our studies in Nairobi, Kenya, show that most women tested after giving informed consent did not actively request their results, less than one third informed their partner, and violence against women because of a positive HIV-antibody test was common. It is important to have carefully designed protocols weighing the benefits against the potential harms for women participating in a study. Even after having consented to HIV testing, women should have the right not to be told their result.

  8. Test Results for Entry Guidance Methods for Space Vehicles

    NASA Technical Reports Server (NTRS)

    Hanson, John M.; Jones, Robert E.

    2004-01-01

    There are a number of approaches to advanced guidance and control that have the potential for achieving the goals of significantly increasing reusable launch vehicle (or any space vehicle that enters an atmosphere) safety and reliability, and reducing the cost. This paper examines some approaches to entry guidance. An effort called Integration and Testing of Advanced Guidance and Control Technologies has recently completed a rigorous testing phase where these algorithms faced high-fidelity vehicle models and were required to perform a variety of representative tests. The algorithm developers spent substantial effort improving the algorithm performance in the testing. This paper lists the test cases used to demonstrate that the desired results are achieved, shows an automated test scoring method that greatly reduces the evaluation effort required, and displays results of the tests. Results show a significant improvement over previous guidance approaches. The two best-scoring algorithm approaches show roughly equivalent results and are ready to be applied to future vehicle concepts.

  9. Advanced quantitative measurement methodology in physics education research

    NASA Astrophysics Data System (ADS)

    Wang, Jing

    The ultimate goal of physics education research (PER) is to develop a theoretical framework to understand and improve the learning process. In this journey of discovery, assessment serves as our headlamp and alpenstock. It sometimes detects signals in student mental structures, and sometimes presents the difference between expert understanding and novice understanding. Quantitative assessment is an important area in PER. Developing research-based effective assessment instruments and making meaningful inferences based on these instruments have always been important goals of the PER community. Quantitative studies are often conducted to provide bases for test development and result interpretation. Statistics are frequently used in quantitative studies. The selection of statistical methods and interpretation of the results obtained by these methods shall be connected to the education background. In this connecting process, the issues of educational models are often raised. Many widely used statistical methods do not make assumptions on the mental structure of subjects, nor do they provide explanations tailored to the educational audience. There are also other methods that consider the mental structure and are tailored to provide strong connections between statistics and education. These methods often involve model assumption and parameter estimation, and are complicated mathematically. The dissertation provides a practical view of some advanced quantitative assessment methods. The common feature of these methods is that they all make educational/psychological model assumptions beyond the minimum mathematical model. The purpose of the study is to provide a comparison between these advanced methods and the pure mathematical methods. The comparison is based on the performance of the two types of methods under physics education settings. In particular, the comparison uses both physics content assessments and scientific ability assessments. The dissertation includes three

  10. Bence-Jones protein - quantitative

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/003597.htm Quantitative Bence-Jones protein test To use the sharing ... Todd Gersten, MD, Hematology/Oncology, Florida Cancer Specialists & Research Institute, Wellington, FL. Review provided by VeriMed Healthcare ...

  11. 12 CFR 252.157 - Disclosure of stress test results.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 12 Banks and Banking 4 2014-01-01 2014-01-01 false Disclosure of stress test results. 252.157... Companies § 252.157 Disclosure of stress test results. (a) Public disclosure of results—(1) In general. (i... loan holding company, or state member bank must disclose a summary of the results of the stress test in...

  12. 12 CFR 252.157 - Disclosure of stress test results.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 12 Banks and Banking 4 2013-01-01 2013-01-01 false Disclosure of stress test results. 252.157... Companies § 252.157 Disclosure of stress test results. (a) Public disclosure of results—(1) In general. (i... loan holding company, or state member bank must disclose a summary of the results of the stress test in...

  13. 40 CFR 205.171-7 - Reporting of the test results.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Reporting of the test results. 205.171... Reporting of the test results. (a)(1) The manufacturer must submit a copy of the test report for all testing...) Year, make serial number, and model of test motorcycle; and (iv) Test results by serial numbers. (b) In...

  14. 40 CFR 205.171-7 - Reporting of the test results.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Reporting of the test results. 205.171... Reporting of the test results. (a)(1) The manufacturer must submit a copy of the test report for all testing...) Year, make serial number, and model of test motorcycle; and (iv) Test results by serial numbers. (b) In...

  15. 40 CFR 205.171-7 - Reporting of the test results.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Reporting of the test results. 205.171... Reporting of the test results. (a)(1) The manufacturer must submit a copy of the test report for all testing...) Year, make serial number, and model of test motorcycle; and (iv) Test results by serial numbers. (b) In...

  16. 40 CFR 205.171-7 - Reporting of the test results.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Reporting of the test results. 205.171... Reporting of the test results. (a)(1) The manufacturer must submit a copy of the test report for all testing...) Year, make serial number, and model of test motorcycle; and (iv) Test results by serial numbers. (b) In...

  17. 40 CFR 205.171-7 - Reporting of the test results.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Reporting of the test results. 205.171... Reporting of the test results. (a)(1) The manufacturer must submit a copy of the test report for all testing...) Year, make serial number, and model of test motorcycle; and (iv) Test results by serial numbers. (b) In...

  18. Uprated OMS Engine Status-Sea Level Testing Results

    NASA Technical Reports Server (NTRS)

    Bertolino, J. D.; Boyd, W. C.

    1990-01-01

    The current Space Shuttle Orbital Maneuvering Engine (OME) is pressure fed, utilizing storable propellants. Performance uprating of this engine, through the use of a gas generator driven turbopump to increase operating pressure, is being pursued by the NASA Johnson Space Center (JSC). Component level design, fabrication, and test activities for this engine system have been on-going since 1984. More recently, a complete engine designated the Integrated Component Test Bed (ICTB), was tested at sea level conditions by Aerojet. A description of the test hardware and results of the sea level test program are presented. These results, which include the test condition operating envelope and projected performance at altitude conditions, confirm the capability of the selected Uprated OME (UOME) configuration to meet or exceed performance and operational requirements. Engine flexibility, demonstrated through testing at two different operational mixture ratios, along with a summary of projected Space Shuttle performance enhancements using the UOME, are discussed. Planned future activities, including ICTB tests at simulated altitude conditions, and recommendations for further engine development, are also discussed.

  19. 40 CFR 94.508 - Calculation and reporting of test results.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... results. 94.508 Section 94.508 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Line Testing Programs § 94.508 Calculation and reporting of test results. (a) Manufacturers shall calculate initial test results using the applicable test procedure specified in § 94.506(a). These results...

  20. 40 CFR 94.508 - Calculation and reporting of test results.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... results. 94.508 Section 94.508 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Line Testing Programs § 94.508 Calculation and reporting of test results. (a) Manufacturers shall calculate initial test results using the applicable test procedure specified in § 94.506(a). These results...

  1. Boeing's STAR-FODB test results

    NASA Astrophysics Data System (ADS)

    Fritz, Martin E.; de la Chapelle, Michael; Van Ausdal, Arthur W.

    1995-05-01

    Boeing has successfully concluded a 2 1/2 year, two phase developmental contract for the STAR-Fiber Optic Data Bus (FODB) that is intended for future space-based applications. The first phase included system analysis, trade studies, behavior modeling, and architecture and protocal selection. During this phase we selected AS4074 Linear Token Passing Bus (LTPB) protocol operating at 200 Mbps, along with the passive, star-coupled fiber media. The second phase involved design, build, integration, and performance and environmental test of brassboard hardware. The resulting brassboard hardware successfully passed performance testing, providing 200 Mbps operation with a 32 X 32 star-coupled medium. This hardware is suitable for a spaceflight experiment to validate ground testing and analysis and to demonstrate performace in the intended environment. The fiber bus interface unit (FBIU) is a multichip module containing transceiver, protocol, and data formatting chips, buffer memory, and a station management controller. The FBIU has been designed for low power, high reliability, and radiation tolerance. Nine FBIUs were built and integrated with the fiber optic physical layer consisting of the fiber cable plant (FCP) and star coupler assembly (SCA). Performance and environmental testing, including radiation exposure, was performed on selected FBIUs and the physical layer. The integrated system was demonstrated with a full motion color video image transfer across the bus while simultaneously performing utility functions with a fiber bus control module (FBCM) over a telemetry and control (T&C) bus, in this case AS1773.

  2. Test-retest and interobserver reliability of quantitative sensory testing according to the protocol of the German Research Network on Neuropathic Pain (DFNS): a multi-centre study.

    PubMed

    Geber, Christian; Klein, Thomas; Azad, Shahnaz; Birklein, Frank; Gierthmühlen, Janne; Huge, Volker; Lauchart, Meike; Nitzsche, Dorothee; Stengel, Maike; Valet, Michael; Baron, Ralf; Maier, Christoph; Tölle, Thomas; Treede, Rolf-Detlef

    2011-03-01

    Quantitative sensory testing (QST) is an instrument to assess positive and negative sensory signs, helping to identify mechanisms underlying pathologic pain conditions. In this study, we evaluated the test-retest reliability (TR-R) and the interobserver reliability (IO-R) of QST in patients with sensory disturbances of different etiologies. In 4 centres, 60 patients (37 male and 23 female, 56.4±1.9years) with lesions or diseases of the somatosensory system were included. QST comprised 13 parameters including detection and pain thresholds for thermal and mechanical stimuli. QST was performed in the clinically most affected test area and a less or unaffected control area in a morning and an afternoon session on 2 consecutive days by examiner pairs (4 QSTs/patient). For both, TR-R and IO-R, there were high correlations (r=0.80-0.93) at the affected test area, except for wind-up ratio (TR-R: r=0.67; IO-R: r=0.56) and paradoxical heat sensations (TR-R: r=0.35; IO-R: r=0.44). Mean IO-R (r=0.83, 31% unexplained variance) was slightly lower than TR-R (r=0.86, 26% unexplained variance, P<.05); the difference in variance amounted to 5%. There were no differences between study centres. In a subgroup with an unaffected control area (n=43), reliabilities were significantly better in the test area (TR-R: r=0.86; IO-R: r=0.83) than in the control area (TR-R: r=0.79; IO-R: r=0.71, each P<.01), suggesting that disease-related systematic variance enhances reliability of QST. We conclude that standardized QST performed by trained examiners is a valuable diagnostic instrument with good test-retest and interobserver reliability within 2days. With standardized training, observer bias is much lower than random variance. Quantitative sensory testing performed by trained examiners is a valuable diagnostic instrument with good interobserver and test-retest reliability for use in patients with sensory disturbances of different etiologies to help identify mechanisms of neuropathic and non

  3. Potential for false positive HIV test results with the serial rapid HIV testing algorithm

    PubMed Central

    2012-01-01

    Background Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Results Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Conclusion Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals. PMID:22429706

  4. MR Morphology of Triangular Fibrocartilage Complex: Correlation with Quantitative MR and Biomechanical Properties

    PubMed Central

    Bae, Won C.; Ruangchaijatuporn, Thumanoon; Chang, Eric Y; Biswas, Reni; Du, Jiang; Statum, Sheronda

    2016-01-01

    Objective To evaluate pathology of the triangular fibrocartilage complex (TFCC) using high resolution morphologic magnetic resonance (MR) imaging, and compare with quantitative MR and biomechanical properties. Materials and Methods Five cadaveric wrists (22 to 70 yrs) were imaged at 3T using morphologic (proton density weighted spin echo, PD FS, and 3D spoiled gradient echo, 3D SPGR) and quantitative MR sequences to determine T2 and T1rho properties. In eight geographic regions, morphology of TFC disc and laminae were evaluated for pathology and quantitative MR values. Samples were disarticulated and biomechanical indentation testing was performed on the distal surface of the TFC disc. Results On morphologic PD SE images, TFC disc pathology included degeneration and tears, while that of the laminae included degeneration, degeneration with superimposed tear, mucinous transformation, and globular calcification. Punctate calcifications were highly visible on 3D SPGR images and found only in pathologic regions. Disc pathology occurred more frequently in proximal regions of the disc than distal regions. Quantitative MR values were lowest in normal samples, and generally higher in pathologic regions. Biomechanical testing demonstrated an inverse relationship, with indentation modulus being high in normal regions with low MR values. The laminae studied were mostly pathologic, and additional normal samples are needed to discern quantitative changes. Conclusion These results show technical feasibility of morphologic MR, quantitative MR, and biomechanical techniques to characterize pathology of the TFCC. Quantitative MRI may be a suitable surrogate marker of soft tissue mechanical properties, and a useful adjunct to conventional morphologic MR techniques. PMID:26691643

  5. hCG Test (Pregnancy Test)

    MedlinePlus

    ... Time and International Normalized Ratio (PT/INR) PSEN1 Quantitative Immunoglobulins Red Blood Cell (RBC) Antibody Identification Red ... Us Also Known As Pregnancy Test Qualitative hCG Quantitative hCG Beta hCG Total hCG Total beta hCG ...

  6. Experimental Psychological Stress on Quantitative Sensory Testing Response in Patients with Temporomandibular Disorders.

    PubMed

    Araújo Oliveira Ferreira, Dyna Mara; Costa, Yuri Martins; de Quevedo, Henrique Müller; Bonjardim, Leonardo Rigoldi; Rodrigues Conti, Paulo César

    2018-05-15

    To assess the modulatory effects of experimental psychological stress on the somatosensory evaluation of myofascial temporomandibular disorder (TMD) patients. A total of 20 women with myofascial TMD and 20 age-matched healthy women were assessed by means of a standardized battery of quantitative sensory testing. Cold detection threshold (CDT), warm detection threshold (WDT), cold pain threshold (CPT), heat pain threshold (HPT), mechanical pain threshold (MPT), wind-up ratio (WUR), and pressure pain threshold (PPT) were performed on the facial skin overlying the masseter muscle. The variables were measured in three sessions: before (baseline) and immediately after the Paced Auditory Serial Addition Task (PASAT) (stress) and then after a washout period of 20 to 30 minutes (poststress). Mixed analysis of variance (ANOVA) was applied to the data, and the significance level was set at P = .050. A significant main effect of the experimental session on all thermal tests was found (ANOVA: F > 4.10, P < .017), where detection tests presented an increase in thresholds in the poststress session compared to baseline (CDT, P = .012; WDT, P = .040) and pain thresholds were reduced in the stress (CPT, P < .001; HPT, P = .001) and poststress sessions (CPT, P = .005; HPT, P = .006) compared to baseline. In addition, a significant main effect of the study group on all mechanical tests (MPT, WUR, and PPT) was found (ANOVA: F > 4.65, P < .037), where TMD patients were more sensitive than healthy volunteers. Acute mental stress conditioning can modulate thermal sensitivity of the skin overlying the masseter in myofascial TMD patients and healthy volunteers. Therefore, psychological stress should be considered in order to perform an unbiased somatosensory assessment of TMD patients.

  7. Dynamic Docking Test System (DDTS) active table frequency response test results. [Apollo Soyuz Test Project

    NASA Technical Reports Server (NTRS)

    Gates, R. M.

    1974-01-01

    Results are presented of the frequency response test performed on the dynamic docking test system (DDTS) active table. Sinusoidal displacement commands were applied to the table and the dynamic response determined from measured actuator responses and accelerometers mounted to the table and one actuator.

  8. Advanced Stirling Convertor Dynamic Test Approach and Results

    NASA Technical Reports Server (NTRS)

    Meer, David W.; Hill, Dennis; Ursic, Joseph

    2009-01-01

    The U.S. Department of Energy (DOE), Lockheed Martin (LM), and NASA Glenn Research Center (GRC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. As part of the extended operation testing of this power system, the Advanced Stirling Converters (ASC) at NASA John H. Glenn Research Center undergo a vibration test sequence intended to simulate the vibration history of an ASC used in an ASRG for a space mission. This sequence includes testing at Workmanship and Flight Acceptance levels interspersed with periods of extended operation to simulate pre and post fueling. The final step in the test sequence utilizes additional testing at Flight Acceptance levels to simulate launch. To better replicate the acceleration profile seen by an ASC incorporated into an ASRG, the input spectra used in testing the convertors was modified based on dynamic testing of the ASRG Engineering Unit ( ASRG-EU) at Lockheed Martin. This paper presents the vibration test plan for current and future ASC units, including the modified input spectra, and the results of recent tests using these spectra. The test results include data from several accelerometers mounted on the convertors as well as the piston position and output power variables.

  9. Low Emissions RQL Flametube Combustor Component Test Results

    NASA Technical Reports Server (NTRS)

    Holdeman, James D.; Chang, Clarence T.

    2001-01-01

    This report describes and summarizes elements of the High Speed Research (HSR) Low Emissions Rich burn/Quick mix/Lean burn (RQL) flame tube combustor test program. This test program was performed at NASA Glenn Research Center circa 1992. The overall objective of this test program was to demonstrate and evaluate the capability of the RQL combustor concept for High Speed Civil Transport (HSCT) applications with the goal of achieving NOx emission index levels of 5 g/kg-fuel at representative HSCT supersonic cruise conditions. The specific objectives of the tests reported herein were to investigate component performance of the RQL combustor concept for use in the evolution of ultra-low NOx combustor design tools. Test results indicated that the RQL combustor emissions and performance at simulated supersonic cruise conditions were predominantly sensitive to the quick mixer subcomponent performance and not sensitive to fuel injector performance. Test results also indicated the mixing section configuration employing a single row of circular holes was the lowest NOx mixer tested probably due to the initial fast mixing characteristics of this mixing section. However, other quick mix orifice configurations such as the slanted slot mixer produced substantially lower levels of carbon monoxide emissions most likely due to the enhanced circumferential dispersion of the air addition. Test results also suggested that an optimum momentum-flux ratio exists for a given quick mix configuration. This would cause undesirable jet under- or over-penetration for test conditions with momentum-flux ratios below or above the optimum value. Tests conducted to assess the effect of quick mix flow area indicated that reduction in the quick mix flow area produced lower NOx emissions at reduced residence time, but this had no effect on NOx emissions measured at similar residence time for the configurations tested.

  10. Test Results from a High Power Linear Alternator Test Rig

    NASA Technical Reports Server (NTRS)

    Birchenough, Arthur G.; Hervol, David S.; Gardner, Brent G.

    2010-01-01

    Stirling cycle power conversion is an enabling technology that provides high thermodynamic efficiency but also presents unique challenges with regard to electrical power generation, management, and distribution. The High Power Linear Alternator Test Rig (HPLATR) located at the NASA Glenn Research Center (GRC) in Cleveland, OH is a demonstration test bed that simulates electrical power generation from a Stirling engine driven alternator. It implements the high power electronics necessary to provide a well regulated DC user load bus. These power electronics use a novel design solution that includes active rectification and power factor control, active ripple suppression, along with a unique building block approach that permits the use of high voltage or high current alternator designs. This presentation describes the HPLATR, the test program, and the operational results.

  11. Test Results From a High Power Linear Alternator Test Rig

    NASA Technical Reports Server (NTRS)

    Birchenough, Arthur G.; Hervol, David S.; Gardner, Brent G.

    2010-01-01

    Stirling cycle power conversion is an enabling technology that provides high thermodynamic efficiency but also presents unique challenges with regard to electrical power generation, management, and distribution. The High Power Linear Alternator Test Rig (HPLATR) located at the NASA Glenn Research Center (GRC) in Cleveland, Ohio is a demonstration test bed that simulates electrical power generation from a Stirling engine driven alternator. It implements the high power electronics necessary to provide a well regulated DC user load bus. These power electronics use a novel design solution that includes active rectification and power factor control, active ripple suppression, along with a unique building block approach that permits the use of high voltage or high current alternator designs. This report describes the HPLATR, the test program, and the operational results.

  12. Quantitative determination and validation of octreotide acetate using 1 H-NMR spectroscopy with internal standard method.

    PubMed

    Yu, Chen; Zhang, Qian; Xu, Peng-Yao; Bai, Yin; Shen, Wen-Bin; Di, Bin; Su, Meng-Xiang

    2018-01-01

    Quantitative nuclear magnetic resonance (qNMR) is a well-established technique in quantitative analysis. We presented a validated 1 H-qNMR method for assay of octreotide acetate, a kind of cyclic octopeptide. Deuterium oxide was used to remove the undesired exchangeable peaks, which was referred to as proton exchange, in order to make the quantitative signals isolated in the crowded spectrum of the peptide and ensure precise quantitative analysis. Gemcitabine hydrochloride was chosen as the suitable internal standard. Experimental conditions, including relaxation delay time, the numbers of scans, and pulse angle, were optimized first. Then method validation was carried out in terms of selectivity, stability, linearity, precision, and robustness. The assay result was compared with that by means of high performance liquid chromatography, which is provided by Chinese Pharmacopoeia. The statistical F test, Student's t test, and nonparametric test at 95% confidence level indicate that there was no significant difference between these two methods. qNMR is a simple and accurate quantitative tool with no need for specific corresponding reference standards. It has the potential of the quantitative analysis of other peptide drugs and standardization of the corresponding reference standards. Copyright © 2017 John Wiley & Sons, Ltd.

  13. 40 CFR 205.160-5 - Reporting of the test results.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Reporting of the test results. 205.160... test results. (a)(1) The manufacturer must submit a copy of the test report for all testing conducted...; (iii) Vehicle serial number; and (iv) Test results by serial numbers. (b) In the case where an EPA...

  14. 40 CFR 205.160-5 - Reporting of the test results.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Reporting of the test results. 205.160... test results. (a)(1) The manufacturer must submit a copy of the test report for all testing conducted...; (iii) Vehicle serial number; and (iv) Test results by serial numbers. (b) In the case where an EPA...

  15. 40 CFR 205.160-5 - Reporting of the test results.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Reporting of the test results. 205.160... test results. (a)(1) The manufacturer must submit a copy of the test report for all testing conducted...; (iii) Vehicle serial number; and (iv) Test results by serial numbers. (b) In the case where an EPA...

  16. 40 CFR 205.160-5 - Reporting of the test results.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Reporting of the test results. 205.160... test results. (a)(1) The manufacturer must submit a copy of the test report for all testing conducted...; (iii) Vehicle serial number; and (iv) Test results by serial numbers. (b) In the case where an EPA...

  17. 40 CFR 205.160-5 - Reporting of the test results.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Reporting of the test results. 205.160... test results. (a)(1) The manufacturer must submit a copy of the test report for all testing conducted...; (iii) Vehicle serial number; and (iv) Test results by serial numbers. (b) In the case where an EPA...

  18. QUANTITATIVE GENETIC ACTIVITY GRAPHICAL PROFILES FOR USE IN CHEMICAL EVALUATION

    EPA Science Inventory

    A graphic approach termed a Genetic Activity Profile (GAP) has been developed to display a matrix of data on the genetic and related effects of selected chemical agents. he profiles provide a visual overview of the quantitative (doses) and qualitative (test results) data for each...

  19. Quantitative systems toxicology

    PubMed Central

    Bloomingdale, Peter; Housand, Conrad; Apgar, Joshua F.; Millard, Bjorn L.; Mager, Donald E.; Burke, John M.; Shah, Dhaval K.

    2017-01-01

    The overarching goal of modern drug development is to optimize therapeutic benefits while minimizing adverse effects. However, inadequate efficacy and safety concerns remain to be the major causes of drug attrition in clinical development. For the past 80 years, toxicity testing has consisted of evaluating the adverse effects of drugs in animals to predict human health risks. The U.S. Environmental Protection Agency recognized the need to develop innovative toxicity testing strategies and asked the National Research Council to develop a long-range vision and strategy for toxicity testing in the 21st century. The vision aims to reduce the use of animals and drug development costs through the integration of computational modeling and in vitro experimental methods that evaluates the perturbation of toxicity-related pathways. Towards this vision, collaborative quantitative systems pharmacology and toxicology modeling endeavors (QSP/QST) have been initiated amongst numerous organizations worldwide. In this article, we discuss how quantitative structure-activity relationship (QSAR), network-based, and pharmacokinetic/pharmacodynamic modeling approaches can be integrated into the framework of QST models. Additionally, we review the application of QST models to predict cardiotoxicity and hepatotoxicity of drugs throughout their development. Cell and organ specific QST models are likely to become an essential component of modern toxicity testing, and provides a solid foundation towards determining individualized therapeutic windows to improve patient safety. PMID:29308440

  20. 49 CFR 219.605 - Positive drug test results; procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Random Alcohol and Drug Testing Programs § 219.605 Positive drug test results; procedures. (a) [Reserved] (b) Procedures for administrative... 49 Transportation 4 2012-10-01 2012-10-01 false Positive drug test results; procedures. 219.605...

  1. 49 CFR 219.605 - Positive drug test results; procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Random Alcohol and Drug Testing Programs § 219.605 Positive drug test results; procedures. (a) [Reserved] (b) Procedures for administrative... 49 Transportation 4 2010-10-01 2010-10-01 false Positive drug test results; procedures. 219.605...

  2. 49 CFR 219.605 - Positive drug test results; procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Random Alcohol and Drug Testing Programs § 219.605 Positive drug test results; procedures. (a) [Reserved] (b) Procedures for administrative... 49 Transportation 4 2011-10-01 2011-10-01 false Positive drug test results; procedures. 219.605...

  3. 49 CFR 219.605 - Positive drug test results; procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Random Alcohol and Drug Testing Programs § 219.605 Positive drug test results; procedures. (a) [Reserved] (b) Procedures for administrative... 49 Transportation 4 2013-10-01 2013-10-01 false Positive drug test results; procedures. 219.605...

  4. 49 CFR 219.605 - Positive drug test results; procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Random Alcohol and Drug Testing Programs § 219.605 Positive drug test results; procedures. (a) [Reserved] (b) Procedures for administrative... 49 Transportation 4 2014-10-01 2014-10-01 false Positive drug test results; procedures. 219.605...

  5. 12 CFR 252.148 - Disclosure of stress test results.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 12 Banks and Banking 4 2014-01-01 2014-01-01 false Disclosure of stress test results. 252.148... RESERVE SYSTEM (CONTINUED) ENHANCED PRUDENTIAL STANDARDS (REGULATION YY) Company-Run Stress Test Requirements for Covered Companies § 252.148 Disclosure of stress test results. (a) Public disclosure of...

  6. Comparative Validation of Five Quantitative Rapid Test Kits for the Analysis of Salt Iodine Content: Laboratory Performance, User- and Field-Friendliness

    PubMed Central

    Rohner, Fabian; Kangambèga, Marcelline O.; Khan, Noor; Kargougou, Robert; Garnier, Denis; Sanou, Ibrahima; Ouaro, Bertine D.; Petry, Nicolai; Wirth, James P.; Jooste, Pieter

    2015-01-01

    Background Iodine deficiency has important health and development consequences and the introduction of iodized salt as national programs has been a great public health success in the past decades. To render national salt iodization programs sustainable and ensure adequate iodization levels, simple methods to quantitatively assess whether salt is adequately iodized are required. Several methods claim to be simple and reliable, and are available on the market or are in development. Objective This work has validated the currently available quantitative rapid test kits (quantRTK) in a comparative manner for both their laboratory performance and ease of use in field settings. Methods Laboratory performance parameters (linearity, detection and quantification limit, intra- and inter-assay imprecision) were conducted on 5 quantRTK. We assessed inter-operator imprecision using salt of different quality along with the comparison of 59 salt samples from across the globe; measurements were made both in a laboratory and a field setting by technicians and non-technicians. Results from the quantRTK were compared against iodometric titration for validity. An ‘ease-of-use’ rating system was developed to identify the most suitable quantRTK for a given task. Results Most of the devices showed acceptable laboratory performance, but for some of the devices, use by non-technicians revealed poorer performance when working in a routine manner. Of the quantRTK tested, the iCheck® and I-Reader® showed most consistent performance and ease of use, and a newly developed paper-based method (saltPAD) holds promise if further developed. Conclusions User- and field-friendly devices are now available and the most appropriate quantRTK can be selected depending on the number of samples and the budget available. PMID:26401655

  7. 40 CFR 1033.320 - Calculation and reporting of test results.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... results. 1033.320 Section 1033.320 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Production Line Testing and Audit Programs § 1033.320 Calculation and reporting of test results. (a) Calculate initial test results using the applicable test procedure specified in § 1033.315(a). Include...

  8. 40 CFR 1033.320 - Calculation and reporting of test results.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... results. 1033.320 Section 1033.320 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Production Line Testing and Audit Programs § 1033.320 Calculation and reporting of test results. (a) Calculate initial test results using the applicable test procedure specified in § 1033.315(a). Include...

  9. 40 CFR 92.508 - Calculation and reporting of test results.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... results. 92.508 Section 92.508 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Remanufacturer Production Line Testing and Audit Programs § 92.508 Calculation and reporting of test results. (a) Manufacturers and remanufacturers shall calculate initial test results using the applicable test procedure...

  10. 40 CFR 92.508 - Calculation and reporting of test results.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... results. 92.508 Section 92.508 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Remanufacturer Production Line Testing and Audit Programs § 92.508 Calculation and reporting of test results. (a) Manufacturers and remanufacturers shall calculate initial test results using the applicable test procedure...

  11. 40 CFR 90.709 - Calculation and reporting of test results.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... results. 90.709 Section 90.709 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Manufacturer Production Line Testing Program § 90.709 Calculation and reporting of test results. (a) Initial test results are calculated following the applicable test procedure specified in § 90.707 (a). The...

  12. 40 CFR 90.709 - Calculation and reporting of test results.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... results. 90.709 Section 90.709 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Manufacturer Production Line Testing Program § 90.709 Calculation and reporting of test results. (a) Initial test results are calculated following the applicable test procedure specified in § 90.707 (a). The...

  13. 40 CFR 90.709 - Calculation and reporting of test results.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... results. 90.709 Section 90.709 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Manufacturer Production Line Testing Program § 90.709 Calculation and reporting of test results. (a) Initial test results are calculated following the applicable test procedure specified in § 90.707 (a). The...

  14. Cascade Distiller System Performance Testing Interim Results

    NASA Technical Reports Server (NTRS)

    Callahan, Michael R.; Pensinger, Stuart; Sargusingh, Miriam J.

    2014-01-01

    The Cascade Distillation System (CDS) is a rotary distillation system with potential for greater reliability and lower energy costs than existing distillation systems. Based upon the results of the 2009 distillation comparison test (DCT) and recommendations of the expert panel, the Advanced Exploration Systems (AES) Water Recovery Project (WRP) project advanced the technology by increasing reliability of the system through redesign of bearing assemblies and improved rotor dynamics. In addition, the project improved the CDS power efficiency by optimizing the thermoelectric heat pump (TeHP) and heat exchanger design. Testing at the NASA-JSC Advanced Exploration System Water Laboratory (AES Water Lab) using a prototype Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell d International, Torrance, Calif.) with test support equipment and control system developed by Johnson Space Center was performed to evaluate performance of the system with the upgrades as compared to previous system performance. The system was challenged with Solution 1 from the NASA Exploration Life Support (ELS) distillation comparison testing performed in 2009. Solution 1 consisted of a mixed stream containing human-generated urine and humidity condensate. A secondary objective of this testing is to evaluate the performance of the CDS as compared to the state of the art Distillation Assembly (DA) used in the ISS Urine Processor Assembly (UPA). This was done by challenging the system with ISS analog waste streams. This paper details the results of the AES WRP CDS performance testing.

  15. Prognostic value of quantitative sensory testing in low back pain: a systematic review of the literature

    PubMed Central

    Marcuzzi, Anna; Dean, Catherine M; Wrigley, Paul J; Chakiath, Rosemary J; Hush, Julia M

    2016-01-01

    Quantitative sensory testing (QST) measures have recently been shown to predict outcomes in various musculoskeletal and pain conditions. The aim of this systematic review was to summarize the emerging body of evidence investigating the prognostic value of QST measures in people with low back pain (LBP). The protocol for this review was prospectively registered on the International Prospective Register of Systematic Reviews. An electronic search of six databases was conducted from inception to October 2015. Experts in the field were contacted to retrieve additional unpublished data. Studies were included if they were prospective longitudinal in design, assessed at least one QST measure in people with LBP, assessed LBP status at follow-up, and reported the association of QST data with LBP status at follow-up. Statistical pooling of results was not possible due to heterogeneity between studies. Of 6,408 references screened after duplicates removed, three studies were finally included. None of them reported a significant association between the QST measures assessed and the LBP outcome. Three areas at high risk of bias were identified which potentially compromise the validity of these results. Due to the paucity of available studies and the methodological shortcomings identified, it remains unknown whether QST measures are predictive of outcome in LBP. PMID:27660486

  16. Prognostic value of quantitative sensory testing in low back pain: a systematic review of the literature.

    PubMed

    Marcuzzi, Anna; Dean, Catherine M; Wrigley, Paul J; Chakiath, Rosemary J; Hush, Julia M

    2016-01-01

    Quantitative sensory testing (QST) measures have recently been shown to predict outcomes in various musculoskeletal and pain conditions. The aim of this systematic review was to summarize the emerging body of evidence investigating the prognostic value of QST measures in people with low back pain (LBP). The protocol for this review was prospectively registered on the International Prospective Register of Systematic Reviews. An electronic search of six databases was conducted from inception to October 2015. Experts in the field were contacted to retrieve additional unpublished data. Studies were included if they were prospective longitudinal in design, assessed at least one QST measure in people with LBP, assessed LBP status at follow-up, and reported the association of QST data with LBP status at follow-up. Statistical pooling of results was not possible due to heterogeneity between studies. Of 6,408 references screened after duplicates removed, three studies were finally included. None of them reported a significant association between the QST measures assessed and the LBP outcome. Three areas at high risk of bias were identified which potentially compromise the validity of these results. Due to the paucity of available studies and the methodological shortcomings identified, it remains unknown whether QST measures are predictive of outcome in LBP.

  17. Testing new approaches to carbonate system simulation at the reef scale: the ReefSam model first results, application to a question in reef morphology and future challenges.

    NASA Astrophysics Data System (ADS)

    Barrett, Samuel; Webster, Jody

    2016-04-01

    morphology and development are compared with observational data. Despite being a test-bed and work in progress, ReefSAM was able to simulate the Holocene development of One Tree Reef in the Southern Great Barrier Reef (Australia) and was able to improve upon previous modelling attempts in terms of both quantitative measures and qualitative outputs, such as the presence of previously un-simulated reef features. Given the success of the model in simulating the Holocene development of OTR, we used it to quantitatively explore the effect of basement substrate depth and morphology on reef maturity/lagoonal filling (as discussed by Purdy and Gischer 2005). Initial results show a number of non-linear relationships between basement substrate depth, lagoonal filling and volume of sand produced on the reef rims and deposited in the lagoon. Lastly, further testing of the model has revealed new challenges which are likely to manifest in any attempt at reef-scale simulation. Subtly different sets of energy direction and magnitude input parameters (different in each time step but with identical probability distributions across the entire model run) resulted in a wide range of quantitative model outputs. Time step length is a likely contributing factor and the results of further testing to address this challenge will be presented.

  18. MCM - 2 and Ki - 67 as proliferation markers in renal cell carcinoma: A quantitative and semi - quantitative analysis

    PubMed Central

    Mehdi, Muhammad Zain; Nagi, Abdul Hanan; Naseem, Nadia

    2016-01-01

    ABSTRACT Introduction/Background: Fuhrman nuclear grade is the most important histological parameter to predict prognosis in a patient of renal cell carcinoma (RCC). However, it suffers from inter-observer and intra-observer variation giving rise to need of a parameter that not only correlates with nuclear grade but is also objective and reproducible. Proliferation is the measure of aggressiveness of a tumour and it is strongly correlated with Fuhrman nuclear grade, clinical survival and recurrence in RCC. Ki-67 is conventionally used to assess proliferation. Mini-chromosome maintenance 2 (MCM-2) is a lesser known marker of proliferation and identifies a greater proliferation faction. This study was designed to assess the prognostic significance of MCM-2 by comparing it with Fuhrman nuclear grade and Ki-67. Material and Methods: n=50 cases of various ages, stages, histological subtypes and grades of RCC were selected for this study. Immunohistochemical staining using Ki-67(MIB-1, Mouse monoclonal antibody, Dako) and MCM-2 (Mouse monoclonal antibody, Thermo) was performed on the paraffin embedded blocks in the department of Morbid anatomy and Histopathology, University of Health Sciences, Lahore. Labeling indices (LI) were determined by two pathologists independently using quantitative and semi-quantitative analysis. Statistical analysis was carried out using SPSS 20.0. Kruskall-Wallis test was used to determine a correlation of proliferation markers with grade, and Pearson's correlate was used to determine correlation between the two proliferation markers. Results: Labeling index of MCM-2 (median=24.29%) was found to be much higher than Ki-67(median=13.05%). Both markers were significantly related with grade (p=0.00; Kruskall-Wallis test). LI of MCM-2 was found to correlate significantly with LI of Ki-67(r=0.0934;p=0.01 with Pearson's correlate). Results of semi-quantitative analysis correlated well with quantitative analysis. Conclusion: Both Ki-67 and MCM-2 are

  19. The Quantitative Preparation of Future Geoscience Graduate Students

    NASA Astrophysics Data System (ADS)

    Manduca, C. A.; Hancock, G. S.

    2006-12-01

    Modern geoscience is a highly quantitative science. In February, a small group of faculty and graduate students from across the country met to discuss the quantitative preparation of geoscience majors for graduate school. The group included ten faculty supervising graduate students in quantitative areas spanning the earth, atmosphere, and ocean sciences; five current graduate students in these areas; and five faculty teaching undergraduate students in the spectrum of institutions preparing students for graduate work. Discussion focused in four key ares: Are incoming graduate students adequately prepared for the quantitative aspects of graduate geoscience programs? What are the essential quantitative skills are that are required for success in graduate school? What are perceived as the important courses to prepare students for the quantitative aspects of graduate school? What programs/resources would be valuable in helping faculty/departments improve the quantitative preparation of students? The participants concluded that strengthening the quantitative preparation of undergraduate geoscience majors would increase their opportunities in graduate school. While specifics differed amongst disciplines, a special importance was placed on developing the ability to use quantitative skills to solve geoscience problems. This requires the ability to pose problems so they can be addressed quantitatively, understand the relationship between quantitative concepts and physical representations, visualize mathematics, test the reasonableness of quantitative results, creatively move forward from existing models/techniques/approaches, and move between quantitative and verbal descriptions. A list of important quantitative competencies desirable in incoming graduate students includes mechanical skills in basic mathematics, functions, multi-variate analysis, statistics and calculus, as well as skills in logical analysis and the ability to learn independently in quantitative ways

  20. Integrating Quantitative and Qualitative Results in Health Science Mixed Methods Research Through Joint Displays

    PubMed Central

    Guetterman, Timothy C.; Fetters, Michael D.; Creswell, John W.

    2015-01-01

    PURPOSE Mixed methods research is becoming an important methodology to investigate complex health-related topics, yet the meaningful integration of qualitative and quantitative data remains elusive and needs further development. A promising innovation to facilitate integration is the use of visual joint displays that bring data together visually to draw out new insights. The purpose of this study was to identify exemplar joint displays by analyzing the various types of joint displays being used in published articles. METHODS We searched for empirical articles that included joint displays in 3 journals that publish state-of-the-art mixed methods research. We analyzed each of 19 identified joint displays to extract the type of display, mixed methods design, purpose, rationale, qualitative and quantitative data sources, integration approaches, and analytic strategies. Our analysis focused on what each display communicated and its representation of mixed methods analysis. RESULTS The most prevalent types of joint displays were statistics-by-themes and side-by-side comparisons. Innovative joint displays connected findings to theoretical frameworks or recommendations. Researchers used joint displays for convergent, explanatory sequential, exploratory sequential, and intervention designs. We identified exemplars for each of these designs by analyzing the inferences gained through using the joint display. Exemplars represented mixed methods integration, presented integrated results, and yielded new insights. CONCLUSIONS Joint displays appear to provide a structure to discuss the integrated analysis and assist both researchers and readers in understanding how mixed methods provides new insights. We encourage researchers to use joint displays to integrate and represent mixed methods analysis and discuss their value. PMID:26553895

  1. Hercules Aerospace flywheel test results

    NASA Astrophysics Data System (ADS)

    Steele, R. S., Jr.; Babelay, E. F., Jr.; Sutton, B. J.

    1981-06-01

    The detailed results of the spin test evaluation of the Hercules Aerospace flywheel at the Oak Ridge Flywheel Evaluation Laboratory (ORFEL) are presented. Details of the static evaluation with radiography and measures of weight, inertia and natural frequencies are included. The flywheel was spun four times with the maximum speed being increased with each run. During the final run, the flywheel achieved 372 rps and stored 0.714 kWhr of kinetic energy at 37 Whr/kg. The ultimate speed was limited by a composite transverse strength that was somewhat lower than that used in the design of the flywheel. This resulted in internal cracking of the flywheel and, eventually, the loss of material from the outer circumference.

  2. Four-point bending as a method for quantitatively evaluating spinal arthrodesis in a rat model.

    PubMed

    Robinson, Samuel T; Svet, Mark T; Kanim, Linda A; Metzger, Melodie F

    2015-02-01

    The most common method of evaluating the success (or failure) of rat spinal fusion procedures is manual palpation testing. Whereas manual palpation provides only a subjective binary answer (fused or not fused) regarding the success of a fusion surgery, mechanical testing can provide more quantitative data by assessing variations in strength among treatment groups. We here describe a mechanical testing method to quantitatively assess single-level spinal fusion in a rat model, to improve on the binary and subjective nature of manual palpation as an end point for fusion-related studies. We tested explanted lumbar segments from Sprague-Dawley rat spines after single-level posterolateral fusion procedures at L4-L5. Segments were classified as 'not fused,' 'restricted motion,' or 'fused' by using manual palpation testing. After thorough dissection and potting of the spine, 4-point bending in flexion then was applied to the L4-L5 motion segment, and stiffness was measured as the slope of the moment-displacement curve. Results demonstrated statistically significant differences in stiffness among all groups, which were consistent with preliminary grading according to manual palpation. In addition, the 4-point bending results provided quantitative information regarding the quality of the bony union formed and therefore enabled the comparison of fused specimens. Our results demonstrate that 4-point bending is a simple, reliable, and effective way to describe and compare results among rat spines after fusion surgery.

  3. Quantitative analysis of rib movement based on dynamic chest bone images: preliminary results

    NASA Astrophysics Data System (ADS)

    Tanaka, R.; Sanada, S.; Oda, M.; Mitsutaka, M.; Suzuki, K.; Sakuta, K.; Kawashima, H.

    2014-03-01

    Rib movement during respiration is one of the diagnostic criteria in pulmonary impairments. In general, the rib movement is assessed in fluoroscopy. However, the shadows of lung vessels and bronchi overlapping ribs prevent accurate quantitative analysis of rib movement. Recently, an image-processing technique for separating bones from soft tissue in static chest radiographs, called "bone suppression technique", has been developed. Our purpose in this study was to evaluate the usefulness of dynamic bone images created by the bone suppression technique in quantitative analysis of rib movement. Dynamic chest radiographs of 10 patients were obtained using a dynamic flat-panel detector (FPD). Bone suppression technique based on a massive-training artificial neural network (MTANN) was applied to the dynamic chest images to create bone images. Velocity vectors were measured in local areas on the dynamic bone images, which formed a map. The velocity maps obtained with bone and original images for scoliosis and normal cases were compared to assess the advantages of bone images. With dynamic bone images, we were able to quantify and distinguish movements of ribs from those of other lung structures accurately. Limited rib movements of scoliosis patients appeared as reduced rib velocity vectors. Vector maps in all normal cases exhibited left-right symmetric distributions, whereas those in abnormal cases showed nonuniform distributions. In conclusion, dynamic bone images were useful for accurate quantitative analysis of rib movements: Limited rib movements were indicated as a reduction of rib movement and left-right asymmetric distribution on vector maps. Thus, dynamic bone images can be a new diagnostic tool for quantitative analysis of rib movements without additional radiation dose.

  4. 49 CFR 219.206 - FRA access to breath test results.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...

  5. 49 CFR 219.206 - FRA access to breath test results.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...

  6. 49 CFR 219.206 - FRA access to breath test results.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...

  7. 49 CFR 219.206 - FRA access to breath test results.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...

  8. 49 CFR 219.206 - FRA access to breath test results.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...

  9. 78 FR 52166 - Quantitative Messaging Research

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-22

    ... COMMODITY FUTURES TRADING COMMISSION Quantitative Messaging Research AGENCY: Commodity Futures... survey will follow qualitative message testing research (for which CFTC received fast-track OMB approval... message testing research (for which CFTC received fast-track OMB approval) and is necessary to identify...

  10. Hawaiian Electric Advanced Inverter Test Plan - Result Summary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoke, Anderson; Nelson, Austin; Prabakar, Kumaraguru

    This presentation is intended to share the results of lab testing of five PV inverters with the Hawaiian Electric Companies and other stakeholders and interested parties. The tests included baseline testing of advanced inverter grid support functions, as well as distribution circuit-level tests to examine the impact of the PV inverters on simulated distribution feeders using power hardware-in-the-loop (PHIL) techniques. hardware-in-the-loop (PHIL) techniques.

  11. Rigour in quantitative research.

    PubMed

    Claydon, Leica Sarah

    2015-07-22

    This article which forms part of the research series addresses scientific rigour in quantitative research. It explores the basis and use of quantitative research and the nature of scientific rigour. It examines how the reader may determine whether quantitative research results are accurate, the questions that should be asked to determine accuracy and the checklists that may be used in this process. Quantitative research has advantages in nursing, since it can provide numerical data to help answer questions encountered in everyday practice.

  12. Comparison of quantitative cytomegalovirus (CMV) PCR in plasma and CMV antigenemia assay: clinical utility of the prototype AMPLICOR CMV MONITOR test in transplant recipients.

    PubMed

    Caliendo, A M; St George, K; Kao, S Y; Allega, J; Tan, B H; LaFontaine, R; Bui, L; Rinaldo, C R

    2000-06-01

    The correlation between the prototype AMPLICOR CMV MONITOR test (Roche Molecular Systems), a quantitative PCR assay, and the cytomegalovirus (CMV) pp65 antigenemia assay was evaluated in transplant recipients. Sequential blood specimens were collected on 29 patients (491 specimens), the leukocyte fraction was tested by CMV antigenemia, and quantitative PCR was performed on plasma specimens. None of the 15 patients (242 specimens) who were antigenemia negative were positive for CMV DNA by PCR, and none of these patients developed active CMV disease. There were 14 antigenemia-positive patients, 8 of whom developed active CMV disease. In all patients, there was a good association between the antigenemia and PCR assays. Ganciclovir-resistant virus was isolated from three patients with active CMV disease. These three patients had persistently elevated levels of antigenemia and CMV DNA by PCR when resistance to ganciclovir developed. This standardized, quantitative CMV PCR assay on plasma has clinical utility for the diagnosis of active disease and in monitoring the response to antiviral therapy in transplant recipients.

  13. Comparison of Quantitative Cytomegalovirus (CMV) PCR in Plasma and CMV Antigenemia Assay: Clinical Utility of the Prototype AMPLICOR CMV MONITOR Test in Transplant Recipients

    PubMed Central

    Caliendo, Angela M.; St. George, Kirsten; Kao, Shaw-Yi; Allega, Jessica; Tan, Ban-Hock; LaFontaine, Robert; Bui, Larry; Rinaldo, Charles R.

    2000-01-01

    The correlation between the prototype AMPLICOR CMV MONITOR test (Roche Molecular Systems), a quantitative PCR assay, and the cytomegalovirus (CMV) pp65 antigenemia assay was evaluated in transplant recipients. Sequential blood specimens were collected on 29 patients (491 specimens), the leukocyte fraction was tested by CMV antigenemia, and quantitative PCR was performed on plasma specimens. None of the 15 patients (242 specimens) who were antigenemia negative were positive for CMV DNA by PCR, and none of these patients developed active CMV disease. There were 14 antigenemia-positive patients, 8 of whom developed active CMV disease. In all patients, there was a good association between the antigenemia and PCR assays. Ganciclovir-resistant virus was isolated from three patients with active CMV disease. These three patients had persistently elevated levels of antigenemia and CMV DNA by PCR when resistance to ganciclovir developed. This standardized, quantitative CMV PCR assay on plasma has clinical utility for the diagnosis of active disease and in monitoring the response to antiviral therapy in transplant recipients. PMID:10834964

  14. Physician pattern of patient notification of test results.

    PubMed

    Thiedke, Carolyn C; Hoeft, Katherine A; Pearson, William S

    2005-01-01

    To discover how community-based family physicians notify patients of test results and whether there are differences based on sex, length of time in practice, reimbursement status, employment status,or percentage of practice in managed care. We mailed a survey to 500 randomly selected members of the South Carolina chapter of the American Academy of Family Physicians. All analyses were preformed using SASTM version 8.2. Both descriptive and inferential statistics were used to analyze the collected data. A total of 367 physicians responded (73% response rate). The main outcome variable was the time each physician spent notifying patients of test results: a mean of 20.86 +/- 18.3 minutes per day(range 0-120 minutes/day). Women physicians and those with more than 75% managed care were significantly more likely to spend more than the median time notifying patients of test results. Physicians vary in the amount of time they spend notifying patients of their test results, with female physicians and those with more than 75% of their practice in managed care spending more time than do male physicians and physicians with less managed care.

  15. 40 CFR 205.57-5 - Reporting of the test results.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Reporting of the test results. 205.57... Reporting of the test results. (a) Within 5 working days after completion of testing of all vehicles in a... was authorized by the Administrator, and, if any, the test results for the replaced vehicles. (4) A...

  16. 40 CFR 205.57-5 - Reporting of the test results.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Reporting of the test results. 205.57... Reporting of the test results. (a) Within 5 working days after completion of testing of all vehicles in a... was authorized by the Administrator, and, if any, the test results for the replaced vehicles. (4) A...

  17. 40 CFR 205.57-5 - Reporting of the test results.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Reporting of the test results. 205.57... Reporting of the test results. (a) Within 5 working days after completion of testing of all vehicles in a... was authorized by the Administrator, and, if any, the test results for the replaced vehicles. (4) A...

  18. 40 CFR 205.57-5 - Reporting of the test results.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Reporting of the test results. 205.57... Reporting of the test results. (a) Within 5 working days after completion of testing of all vehicles in a... was authorized by the Administrator, and, if any, the test results for the replaced vehicles. (4) A...

  19. 40 CFR 205.57-5 - Reporting of the test results.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Reporting of the test results. 205.57-5... the test results. (a) Within 5 working days after completion of testing of all vehicles in a batch... was authorized by the Administrator, and, if any, the test results for the replaced vehicles. (4) A...

  20. EVALUATING TOOLS AND MODELS USED FOR QUANTITATIVE EXTRAPOLATION OF IN VITRO TO IN VIVO DATA FOR NEUROTOXICANTS*

    EPA Science Inventory

    There are a number of risk management decisions, which range from prioritization for testing to quantitative risk assessments. The utility of in vitro studies in these decisions depends on how well the results of such data can be qualitatively and quantitatively extrapolated to i...

  1. What do Key Stakeholders Think About HIV Self-Testing in Canada? Results from a Cross-Sectional Survey.

    PubMed

    Pai, N Pant; Smallwood, M; Gulati, D; Lapczak, N; Musten, A; Gaydos, C; Johnston, C; Steben, M; Wong, T; Engel, N; Kim, J

    2018-02-01

    Human immunodeficiency virus (HIV) self-testing presents an empowering alternative to facility-based testing for reaching undiagnosed HIV infected individuals, but is not currently available in Canada. We surveyed stakeholders (clinical providers, public health professionals, researchers) engaged in HIV testing initiatives nationwide to identify the concerns, opportunities and challenges to implementing HIV self-testing in Canada. An online cross-sectional survey was disseminated by the Canadian Institutes of Health Research Centre for REACH 2.0 National HIV & sexually transmitted and blood borne infections working group to stakeholders nationwide, with a target sample size of 200. Quantitative and qualitative data were analyzed using a mixed-methods, respondent-informed approach, to inform subsequent HIV self-testing in a country where self-testing is not yet accessible. A total of 183 responses were received. A majority (70.7%) (128/181) felt that self-testing was a necessary investment to reach the undiagnosed. 64.6% (117/181) felt that self-tests should be made available to their clients and 71.5% (128/179) of respondents agreed that self-test instructions required improvements. However, 50% (90/180) felt that self-testing will pose an economic challenge to current HIV testing models. Regardless, 21% urged for timely action and availability of HIV self-tests. Thematic analyses reflected the following concerns: (a) need for affordable self-tests, (b) need for expedited, customized, and accessible linkages to counselling, (c) concern for patients to cope with positive self-test results, (d) accuracy of self-tests to detect acute HIV and (e) liability in the context of non-disclosure. Stakeholders agreed to the provision of an option of HIV self-testing to reach the undiagnosed individuals. Concerns regarding costs and accuracy of self-tests, expedited linkages to counselling, and integration of self-test within prevailing HIV testing models, will need to be

  2. Hepatitis C Test

    MedlinePlus

    ... Time and International Normalized Ratio (PT/INR) PSEN1 Quantitative Immunoglobulins Red Blood Cell (RBC) Antibody Identification Red ... monitor treatment: HCV RNA tests: HCV RNA test, Quantitative (HCV viral load) detects and measures the number ...

  3. Quantitative sensory testing of temperature, pain, and touch in adults with Down syndrome.

    PubMed

    de Knegt, Nanda; Defrin, Ruth; Schuengel, Carlo; Lobbezoo, Frank; Evenhuis, Heleen; Scherder, Erik

    2015-12-01

    The spinothalamic pathway mediates sensations of temperature, pain, and touch. These functions seem impaired in children with Down syndrome (DS), but have not been extensively examined in adults. The objective of the present study was to compare the spinothalamic-mediated sensory functions between adults with DS and adults from the general population and to examine in the DS group the relationship between the sensory functions and level of intellectual functioning. Quantitative sensory testing (QST) was performed in 188 adults with DS (mean age 37.5 years) and 142 age-matched control participants (median age 40.5 years). Temperature, pain, and touch were evaluated with tests for cold-warm discrimination, sharp-dull discrimination (pinprick), and tactile threshold, respectively. Level of intellectual functioning was estimated with the Social Functioning Scale for Intellectual Disability (intellectual disability level) and the Wechsler Preschool and Primary Scale of Intelligence--Revised (intelligence level). Overall, the difference in spinothalamic-mediated sensory functions between the DS and control groups was not statistically significant. However, DS participants with a lower intelligence level had a statistically significant lower performance on the sharp-dull discrimination test than DS participants with higher intelligence level (adjusted p=.006) and control participants (adjusted p=.017). It was concluded that intellectual functioning level is an important factor to take into account for the assessment of spinothalamic-mediated sensory functioning in adults with DS: a lower level could coincide with impaired sensory functioning, but could also hamper QST assessment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Evaluation of the quantitative fetal fibronectin test and PAMG-1 test for the prediction of spontaneous preterm birth in patients with signs and symptoms suggestive of preterm labor.

    PubMed

    Ravi, Mini; Beljorie, Mercy; El Masry, Karim

    2018-05-28

    The objective of this study is to compare the qualitative fFN test at 50 ng/ml threshold to novel methods for assessing risk of imminent sPTB in women with symptoms of preterm labor (PTL): (1) quantitative fetal fibronectin (qfFN) at four thresholds: 10, 50, 200, and 500 ng/ml; and (2) qualitative PAMG-1 test. Consecutive patients presenting with singleton pregnancies, signs of PTL, gestational age 23.1-34.6, intact membranes, no coitus within 24 h, and cervical dilation ≤3 cm. fFN was performed as standard of care, while clinicians were blinded to the qfFN and PAMG-1 test results. qfFN accuracy was evaluated at four thresholds of 10, 50, 200, and 500 ng/ml for its ability to predict imminent spontaneous preterm delivery (sPTD) ≤ 7 and ≤14 d from the time of sample collection. The PAMG-1 test was evaluated based on its qualitative result for the same delivery endpoints. Seventy-two patients were analyzed. Fifty-seven percent of patients had an fFN concentration of <10 ng/ml fFN; 75% < 50 ng/ml; 92% < 200 ng/ml; 97% < 500 ng/ml. The SN, SP, PPV, and NPV for fFN at each of the four cutoffs for sPTB ≤7 d: 10 ng/ml: 67%, 58%, 6%, 98%; 50 ng/ml: 67%, 77%, 11%, 98%; 200 ng/ml: 33%, 93%, 17%, 97%; 500 ng/ml: 0%, 97%, 0%, 96%. The PAMG-1 test was positive in 7% of patients. SN, SP, PPV, and NPV for PAMG-1 for sPTD ≤7 d were 67%, 96%, 40%, and 99%, respectively. Compared with qfFN, the PAMG-1 test is a better predictor of spontaneous delivery within 7 d while maintaining a very high negative predictive value. The PAMG-1 test is an easy-to-use bedside test that provides rapid results, does not require a speculum examination, can be used after vaginal exam and coitus and does not require specialized equipment to analyze results. As to be expected, compared with the conventional cutoff of fFN (50 ng/ml), a higher fFN cutoff of 200 ng/ml does seem to increase the PPV of the test, but this comes at a cost to the f

  5. PRIORITIZING FUTURE RESEACH ON OFF-LABEL PRESCRIBING: RESULTS OF A QUANTITATIVE EVALUATION

    PubMed Central

    Walton, Surrey M.; Schumock, Glen T.; Lee, Ky-Van; Alexander, G. Caleb; Meltzer, David; Stafford, Randall S.

    2015-01-01

    Background Drug use for indications not approved by the Food and Drug Administration exceeds 20% of prescribing. Available compendia indicate that a minority of off-label uses are well supported by evidence. Policy makers, however, lack information to identify where systematic reviews of the evidence or other research would be most valuable. Methods We developed a quantitative model for prioritizing individual drugs for future research on off-label uses. The base model incorporated three key factors, 1) the volume of off-label use with inadequate evidence, 2) safety, and 3) cost and market considerations. Nationally representative prescribing data were used to estimate the number of off-label drug uses by indication from 1/2005 through 6/2007 in the United States, and these indications were then categorized according to the adequacy of scientific support. Black box warnings and safety alerts were used to quantify drug safety. Drug cost, date of market entry, and marketing expenditures were used to quantify cost and market considerations. Each drug was assigned a relative value for each factor, and the factors were then weighted in the final model to produce a priority score. Sensitivity analyses were conducted by varying the weightings and model parameters. Results Drugs that were consistently ranked highly in both our base model and sensitivity analyses included quetiapine, warfarin, escitalopram, risperidone, montelukast, bupropion, sertraline, venlafaxine, celecoxib, lisinopril, duloxetine, trazodone, olanzapine, and epoetin alfa. Conclusion Future research into off-label drug use should focus on drugs used frequently with inadequate supporting evidence, particularly if further concerns are raised by known safety issues, high drug cost, recent market entry, and extensive marketing. Based on quantitative measures of these factors, we have prioritized drugs where targeted research and policy activities have high potential value. PMID:19025425

  6. Racial Battle Fatigue for Latina/o Students: A Quantitative Perspective

    ERIC Educational Resources Information Center

    Franklin, Jeremy D.; Smith, William A.; Hung, Man

    2014-01-01

    Previous literature demonstrates that as a result of racial microaggressions and hostile campus racial climates, Latina/o students often state they experience psychological, physiological, and behavioral stress responses during and after racialized incidents on campuses. The purpose of this study is to quantitatively test the racial battle fatigue…

  7. Ball Aerospace SBMD Coating Test Results

    NASA Technical Reports Server (NTRS)

    Brown, Robert; Lightsey, Paul; Russell, J. Kevin (Technical Monitor)

    2002-01-01

    The Sub-scale Beryllium Mirror Demonstrator that was successfully tested to demonstrate cryogenic figuring of a bare mirror has been coated with a protected gold reflective surface and retested at cryogenic temperatures. Results showing less than 9 nm rms surface distortion attributable to the added coating are presented.

  8. 40 CFR 91.509 - Calculation and reporting of test results.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... results. 91.509 Section 91.509 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Testing Program § 91.509 Calculation and reporting of test results. (a) Initial test results are... rounds these results, in accordance with ASTM E29-93a, to the number of decimal places contained in the...

  9. 40 CFR 91.509 - Calculation and reporting of test results.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... results. 91.509 Section 91.509 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Testing Program § 91.509 Calculation and reporting of test results. (a) Initial test results are... rounds these results, in accordance with ASTM E29-93a, to the number of decimal places contained in the...

  10. 40 CFR 91.509 - Calculation and reporting of test results.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... results. 91.509 Section 91.509 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Testing Program § 91.509 Calculation and reporting of test results. (a) Initial test results are... rounds these results, in accordance with ASTM E29-93a, to the number of decimal places contained in the...

  11. Hercules Aerospace flywheel test results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steele, R.S. Jr.; Babelay, E.F. Jr.; Sutton, B.J.

    1981-06-01

    The detailed results of the spin test evaluation of the Hercules Aerospace flywheel at the Oak Ridge Flywheel Evaluation Laboratory (ORFEL) are presented. Details of the static evaluation with radiography and measures of weight, inertia, and natural frequencies are included. The flywheel was spun four times with the maximum speed being increased with each run. During the final run, the flywheel achieved 372 rps and stored 0.714 kWhr of kinetic energy at 37 Whr/kg. The ultimate speed was limited by a composite transverse strength that was somewhat lower than that used in the design of the flywheel. This resulted inmore » internal cracking of the flywheel and, eventually, the loss of material from the outer circumference.« less

  12. Standardized Test Results: An Opportunity for English Program Improvement

    ERIC Educational Resources Information Center

    Jiménez, Maureyra; Rodríguez, Caroll; Rey Paba, Lourdes

    2017-01-01

    This case study explores the relationship between the results obtained by a group of Industrial Engineering students on a national standardized English test and the impact these results had on language program improvement. The instruments used were interviews, document analysis, observations, surveys, and test results analysis. Findings indicate…

  13. Reliability of intra-oral quantitative sensory testing (QST) in patients with atypical odontalgia and healthy controls - a multicentre study.

    PubMed

    Baad-Hansen, L; Pigg, M; Yang, G; List, T; Svensson, P; Drangsholt, M

    2015-02-01

    The reliability of comprehensive intra-oral quantitative sensory testing (QST) protocol has not been examined systematically in patients with chronic oro-facial pain. The aim of the present multicentre study was to examine test-retest and interexaminer reliability of intra-oral QST measures in terms of absolute values and z-scores as well as within-session coefficients of variation (CV) values in patients with atypical odontalgia (AO) and healthy pain-free controls. Forty-five patients with AO and 68 healthy controls were subjected to bilateral intra-oral gingival QST and unilateral extratrigeminal QST (thenar) on three occasions (twice on 1 day by two different examiners and once approximately 1 week later by one of the examiners). Intra-class correlation coefficients and kappa values for interexaminer and test-retest reliability were computed. Most of the standardised intra-oral QST measures showed fair to excellent interexaminer (9-12 of 13 measures) and test-retest (7-11 of 13 measures) reliability. Furthermore, no robust differences in reliability measures or within-session variability (CV) were detected between patients with AO and the healthy reference group. These reliability results in chronic orofacial pain patients support earlier suggestions based on data from healthy subjects that intra-oral QST is sufficiently reliable for use as a part of a comprehensive evaluation of patients with somatosensory disturbances or neuropathic pain in the trigeminal region. © 2014 John Wiley & Sons Ltd.

  14. Potential for false positive HIV test results with the serial rapid HIV testing algorithm.

    PubMed

    Baveewo, Steven; Kamya, Moses R; Mayanja-Kizza, Harriet; Fatch, Robin; Bangsberg, David R; Coates, Thomas; Hahn, Judith A; Wanyenze, Rhoda K

    2012-03-19

    Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  15. Google glass based immunochromatographic diagnostic test analysis

    NASA Astrophysics Data System (ADS)

    Feng, Steve; Caire, Romain; Cortazar, Bingen; Turan, Mehmet; Wong, Andrew; Ozcan, Aydogan

    2015-03-01

    Integration of optical imagers and sensors into recently emerging wearable computational devices allows for simpler and more intuitive methods of integrating biomedical imaging and medical diagnostics tasks into existing infrastructures. Here we demonstrate the ability of one such device, the Google Glass, to perform qualitative and quantitative analysis of immunochromatographic rapid diagnostic tests (RDTs) using a voice-commandable hands-free software-only interface, as an alternative to larger and more bulky desktop or handheld units. Using the built-in camera of Glass to image one or more RDTs (labeled with Quick Response (QR) codes), our Glass software application uploads the captured image and related information (e.g., user name, GPS, etc.) to our servers for remote analysis and storage. After digital analysis of the RDT images, the results are transmitted back to the originating Glass device, and made available through a website in geospatial and tabular representations. We tested this system on qualitative human immunodeficiency virus (HIV) and quantitative prostate-specific antigen (PSA) RDTs. For qualitative HIV tests, we demonstrate successful detection and labeling (i.e., yes/no decisions) for up to 6-fold dilution of HIV samples. For quantitative measurements, we activated and imaged PSA concentrations ranging from 0 to 200 ng/mL and generated calibration curves relating the RDT line intensity values to PSA concentration. By providing automated digitization of both qualitative and quantitative test results, this wearable colorimetric diagnostic test reader platform on Google Glass can reduce operator errors caused by poor training, provide real-time spatiotemporal mapping of test results, and assist with remote monitoring of various biomedical conditions.

  16. Optimization of an Optical Inspection System Based on the Taguchi Method for Quantitative Analysis of Point-of-Care Testing

    PubMed Central

    Yeh, Chia-Hsien; Zhao, Zi-Qi; Shen, Pi-Lan; Lin, Yu-Cheng

    2014-01-01

    This study presents an optical inspection system for detecting a commercial point-of-care testing product and a new detection model covering from qualitative to quantitative analysis. Human chorionic gonadotropin (hCG) strips (cut-off value of the hCG commercial product is 25 mIU/mL) were the detection target in our study. We used a complementary metal-oxide semiconductor (CMOS) sensor to detect the colors of the test line and control line in the specific strips and to reduce the observation errors by the naked eye. To achieve better linearity between the grayscale and the concentration, and to decrease the standard deviation (increase the signal to noise ratio, S/N), the Taguchi method was used to find the optimal parameters for the optical inspection system. The pregnancy test used the principles of the lateral flow immunoassay, and the colors of the test and control line were caused by the gold nanoparticles. Because of the sandwich immunoassay model, the color of the gold nanoparticles in the test line was darkened by increasing the hCG concentration. As the results reveal, the S/N increased from 43.48 dB to 53.38 dB, and the hCG concentration detection increased from 6.25 to 50 mIU/mL with a standard deviation of less than 10%. With the optimal parameters to decrease the detection limit and to increase the linearity determined by the Taguchi method, the optical inspection system can be applied to various commercial rapid tests for the detection of ketamine, troponin I, and fatty acid binding protein (FABP). PMID:25256108

  17. Quantitative Literacy: Geosciences and Beyond

    NASA Astrophysics Data System (ADS)

    Richardson, R. M.; McCallum, W. G.

    2002-12-01

    Quantitative literacy seems like such a natural for the geosciences, right? The field has gone from its origin as a largely descriptive discipline to one where it is hard to imagine failing to bring a full range of mathematical tools to the solution of geological problems. Although there are many definitions of quantitative literacy, we have proposed one that is analogous to the UNESCO definition of conventional literacy: "A quantitatively literate person is one who, with understanding, can both read and represent quantitative information arising in his or her everyday life." Central to this definition is the concept that a curriculum for quantitative literacy must go beyond the basic ability to "read and write" mathematics and develop conceptual understanding. It is also critical that a curriculum for quantitative literacy be engaged with a context, be it everyday life, humanities, geoscience or other sciences, business, engineering, or technology. Thus, our definition works both within and outside the sciences. What role do geoscience faculty have in helping students become quantitatively literate? Is it our role, or that of the mathematicians? How does quantitative literacy vary between different scientific and engineering fields? Or between science and nonscience fields? We will argue that successful quantitative literacy curricula must be an across-the-curriculum responsibility. We will share examples of how quantitative literacy can be developed within a geoscience curriculum, beginning with introductory classes for nonmajors (using the Mauna Loa CO2 data set) through graduate courses in inverse theory (using singular value decomposition). We will highlight six approaches to across-the curriculum efforts from national models: collaboration between mathematics and other faculty; gateway testing; intensive instructional support; workshops for nonmathematics faculty; quantitative reasoning requirement; and individual initiative by nonmathematics faculty.

  18. UK audit of quantitative thyroid uptake imaging.

    PubMed

    Taylor, Jonathan C; Murray, Anthony W; Hall, David O; Barnfield, Mark C; O'Shaugnessy, Emma R; Carson, Kathryn J; Cullis, James; Towey, David J; Kenny, Bob

    2017-07-01

    A national audit of quantitative thyroid uptake imaging was conducted by the Nuclear Medicine Software Quality Group of the Institute of Physics and Engineering in Medicine in 2014/2015. The aims of the audit were to measure and assess the variability in thyroid uptake results across the UK and to compare local protocols with British Nuclear Medicine Society (BNMS) guidelines. Participants were invited through a combination of emails on a public mailbase and targeted invitations from regional co-ordinators. All participants were given a set of images from which to calculate quantitative measures and a spreadsheet for capturing results. The image data consisted of two sets of 10 anterior thyroid images, half of which were acquired after administration of Tc-pertechnetate and the other half after administration of I-iodide. Images of the administration syringes or thyroid phantoms were also included. In total, 54 participants responded to the audit. The median number of scans conducted per year was 50. A majority of centres had at least one noncompliance in comparison with BNMS guidelines. Of most concern was the widespread lack of injection-site imaging. Quantitative results showed that both intersite and intrasite variability were low for the Tc dataset. The coefficient of quartile deviation was between 0.03 and 0.13 for measurements of overall percentage uptake. Although the number of returns for the I dataset was smaller, the level of variability between participants was greater (the coefficient of quartile deviation was between 0.17 and 0.25). A UK-wide audit showed that thyroid uptake imaging is still a common test in the UK. It was found that most centres do not adhere to all aspects of the BNMS practice guidelines but that quantitative results are reasonably consistent for Tc-based scans.

  19. Uncertainty of quantitative microbiological methods of pharmaceutical analysis.

    PubMed

    Gunar, O V; Sakhno, N G

    2015-12-30

    The total uncertainty of quantitative microbiological methods, used in pharmaceutical analysis, consists of several components. The analysis of the most important sources of the quantitative microbiological methods variability demonstrated no effect of culture media and plate-count techniques in the estimation of microbial count while the highly significant effect of other factors (type of microorganism, pharmaceutical product and individual reading and interpreting errors) was established. The most appropriate method of statistical analysis of such data was ANOVA which enabled not only the effect of individual factors to be estimated but also their interactions. Considering all the elements of uncertainty and combining them mathematically the combined relative uncertainty of the test results was estimated both for method of quantitative examination of non-sterile pharmaceuticals and microbial count technique without any product. These data did not exceed 35%, appropriated for a traditional plate count methods. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Finite Element Analysis and Test Results Comparison for the Hybrid Wing Body Center Section Test Article

    NASA Technical Reports Server (NTRS)

    Przekop, Adam; Jegley, Dawn C.; Rouse, Marshall; Lovejoy, Andrew E.

    2016-01-01

    This report documents the comparison of test measurements and predictive finite element analysis results for a hybrid wing body center section test article. The testing and analysis efforts were part of the Airframe Technology subproject within the NASA Environmentally Responsible Aviation project. Test results include full field displacement measurements obtained from digital image correlation systems and discrete strain measurements obtained using both unidirectional and rosette resistive gauges. Most significant results are presented for the critical five load cases exercised during the test. Final test to failure after inflicting severe damage to the test article is also documented. Overall, good comparison between predicted and actual behavior of the test article is found.

  1. Production Facility Prototype Blower 1000 Hour Test Results II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wass, Alexander Joseph; Woloshun, Keith Albert; Dale, Gregory E.

    Long duration tests of the Aerzen GM 12.4 roots style blower in a closed loop configuration provides valuable data and lessons learned for long-term operation at the Mo-99 production facility. The blower was operated in a closed loop configuration with the flow conditions anticipated in plant operation with a Mo-100 target inline. The additional thermal energy generated from beam heating of the Mo-100 disks were not included in these tests. Five 1000 hour tests have been completed since the first test was performed in January of 2016. All five 1000 hour tests have proven successful in exposing preventable issues relatedmore » to oil and helium leaks. All blower tests to this date have resulted in stable blower performance and consistency. A summary of the results for each test, including a review of the first and second tests, are included in this report.« less

  2. Use of the ciliated protozoan Tetrahymena pyriformis for the assessment of toxicity and quantitative structure--activity relationships of xenobiotics: comparison with the Microtox test.

    PubMed

    Bogaerts, P; Bohatier, J; Bonnemoy, F

    2001-07-01

    Cytotoxicity and quantitative structure-activity relationships of 13 inorganic and 21 organic substances were determined using three bioassays performed on the ciliated protozoan Tetrahymena pyriformis and the luminescent bacterium Vibrio fischeri. The best concordance of toxicity results was observed between the T. pyriformis FDA--esterase activity and population growth inhibition tests for the organic compounds. The sensitivity of these two assays is compared with that of the Microtox test. The T. pyriformis FDA test showed a high sensitivity is most cases. The aim of the current research was to determine whether the relative toxicity of metal ions and organic molecules, with these three bioassays, was predictable using three ion characteristics and hydrophobicity, respectively. For metal ions, the variable that best modeled the toxicity data obtained with the two T. pyriformis tests was the softness index [sigma(p), i.e., (coordinate bond energy of the metal fluoride--coordinate bond energy of the metal iodide)/(coordinate bond energy of the metal fluoride)]. No correlation was found with the Microtox test. For organic compounds, a significant correlation was observed between the hydrophobicity coefficient and the toxicity data. This correlation is closer with the two tests using Tetrahymena. Copyright 2001 Academic Press.

  3. Drug and alcohol testing results 1996 annual report

    DOT National Transportation Integrated Search

    1997-12-01

    The report is a compilation and analysis of mass transit drug and alcohol testing reported by transit systems in the United States during 1996. The report covers testing results for the following drug types: marijuana (THC), cocaine, phencyclidine (P...

  4. 49 CFR 199.119 - Reporting of anti-drug testing results.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Reporting of anti-drug testing results. 199.119... HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.119 Reporting of anti-drug testing results. (a) Each large operator...

  5. 49 CFR 199.119 - Reporting of anti-drug testing results.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Reporting of anti-drug testing results. 199.119... HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.119 Reporting of anti-drug testing results. (a) Each large operator...

  6. 49 CFR 199.119 - Reporting of anti-drug testing results.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Reporting of anti-drug testing results. 199.119... HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.119 Reporting of anti-drug testing results. (a) Each large operator...

  7. 49 CFR 199.119 - Reporting of anti-drug testing results.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Reporting of anti-drug testing results. 199.119... HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.119 Reporting of anti-drug testing results. (a) Each large operator...

  8. 49 CFR 199.119 - Reporting of anti-drug testing results.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Reporting of anti-drug testing results. 199.119... HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.119 Reporting of anti-drug testing results. (a) Each large operator...

  9. HIFiRE-5 Flight Test Preliminary Results (Postprint)

    DTIC Science & Technology

    2013-11-01

    DMARS-R) IMU and Ashtech DG14 Global Positioning System receiver. Results show that a tripped transition occurred on the test article leading edge...Reference System (DMARS-R) IMU and Ashtech DG14 Global Positioning System receiver. Results show that a tripped transition occurred on the test...pitch angle relative to earth as measured by IMU , or flight-path elevation angle as measured by GPS or IMU , degrees  = body-fixed angular coordinate

  10. Drug and alcohol testing results 2002 annual report

    DOT National Transportation Integrated Search

    2005-02-01

    This the 7th annual report of the results of the FTA Drug and Alcohol Testing Program. The report summarizes the new reporting requirements introduced for calendar year 2001, the requirements of the overall drug and alcohol testing program, the resul...

  11. Sims Prototype System 2 test results: Engineering analysis

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The testing, problems encountered, and the results and conclusions obtained from tests performed on the IBM Prototype System, 2, solar hot water system, at the Marshall Space Flight Center Solar Test Facility was described. System 2 is a liquid, non draining solar energy system for supplying domestic hot water to single residences. The system consists of collectors, storage tank, heat exchanger, pumps and associated plumbing and controls.

  12. The NASA B-757 HIRF Test Series: Flight Test Results

    NASA Technical Reports Server (NTRS)

    Moeller, Karl J.; Dudley, Kenneth L.

    1997-01-01

    In 1995, the NASA Langley Research Center conducted a series of aircraft tests aimed at characterizing the electromagnetic environment (EME) in and around a Boeing 757 airliner. Measurements were made of the electromagnetic energy coupled into the aircraft and the signals induced on select structures as the aircraft was flown past known RF transmitters. These measurements were conducted to provide data for the validation of computational techniques for the assessment of electromagnetic effects in commercial transport aircraft. This paper reports on the results of flight tests using RF radiators in the HF, VHF, and UHF ranges and on efforts to use computational and analytical techniques to predict RF field levels inside the airliner at these frequencies.

  13. Allergy Blood Test

    MedlinePlus

    ... have an allergy. Other names: IgE allergy test, Quantitative IgE, Immunoglobulin E, Total IgE, Specific IgE What ... Thermo Fisher Scientific Inc.; c2017. ImmunoCAP – a truly quantitative allergy test [cited 2017 Feb 24]; [about 3 ...

  14. 10 CFR 26.139 - Reporting initial validity and drug test results.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Reporting initial validity and drug test results. 26.139... § 26.139 Reporting initial validity and drug test results. (a) The licensee testing facility shall... permitted under § 26.75(h), positive test results from initial drug tests at the licensee testing facility...

  15. 10 CFR 26.139 - Reporting initial validity and drug test results.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Reporting initial validity and drug test results. 26.139... § 26.139 Reporting initial validity and drug test results. (a) The licensee testing facility shall... permitted under § 26.75(h), positive test results from initial drug tests at the licensee testing facility...

  16. Quantitative risk estimation for large for gestational age using the area under the 100-g oral glucose tolerance test curve.

    PubMed

    Kim, Sollip; Min, Won-Ki; Chun, Sail; Lee, Woochang; Chung, Hee-Jung; Lee, Pil Ryang; Kim, Ahm

    2009-01-01

    We devised a complementary quantitative method for gestational diabetes (GDM) that uses the area under the curve (AUC) of the results of the oral glucose tolerance test (OGTT), and evaluated its efficacy in predicting neonates that would be large for gestational age (LGA). The study subjects were 648 pregnant women. The AUC-OGTT (concentration x time) was calculated from the 100-g OGTT results. The incidence of LGA according to each range of the AUC-OGTT was estimated and odds ratios were analyzed using multiple logistic regression analysis.The incidence of LGA increased with the AUC-OGTT value and was 0% for AUC<300, 7.8% for 300-400, 14.9% for 400-500, 20.8% for 500-600, and 45.5% for > or = 600. The odds ratio of LGA increased by approximately two-fold with an increase of 100 in the AUC-OGTT. The results indicated that the AUC-OGTT can be used to quantify the risk of LGA in GDM. The AUC-OGTT could complement a diagnosis of GDM using conventional diagnostic criteria.

  17. 40 CFR 90.509 - Calculation and reporting of test results.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Calculation and reporting of test... Selective Enforcement Auditing § 90.509 Calculation and reporting of test results. (a) Initial test results... the number of tests conducted on the engine, and rounding to the same number of decimal places...

  18. Steel Containment Vessel Model Test: Results and Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Costello, J.F.; Hashimote, T.; Hessheimer, M.F.

    A high pressure test of the steel containment vessel (SCV) model was conducted on December 11-12, 1996 at Sandia National Laboratories, Albuquerque, NM, USA. The test model is a mixed-scaled model (1:10 in geometry and 1:4 in shell thickness) of an improved Mark II boiling water reactor (BWR) containment. A concentric steel contact structure (CS), installed over the SCV model and separated at a nominally uniform distance from it, provided a simplified representation of a reactor shield building in the actual plant. The SCV model and contact structure were instrumented with strain gages and displacement transducers to record the deformationmore » behavior of the SCV model during the high pressure test. This paper summarizes the conduct and the results of the high pressure test and discusses the posttest metallurgical evaluation results on specimens removed from the SCV model.« less

  19. Quantitative measurement of HER2 expression in breast cancers: comparison with 'real-world' routine HER2 testing in a multicenter Collaborative Biomarker Study and correlation with overall survival.

    PubMed

    Yardley, Denise A; Kaufman, Peter A; Huang, Weidong; Krekow, Lea; Savin, Michael; Lawler, William E; Zrada, Stephen; Starr, Alexander; Einhorn, Harvey; Schwartzberg, Lee S; Adams, John W; Lie, Yolanda; Paquet, Agnes C; Sperinde, Jeff; Haddad, Mojgan; Anderson, Steve; Brigino, Marlon; Pesano, Rick; Bates, Michael P; Weidler, Jodi; Bosserman, Linda

    2015-03-18

    Accurate assessment of HER2 status is critical in determining appropriate therapy for breast cancer patients but the best HER2 testing methodology has yet to be defined. In this study, we compared quantitative HER2 expression by the HERmark™ Breast Cancer Assay (HERmark) with routine HER2 testing by immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH), and correlated HER2 results with overall survival (OS) of breast cancer patients in a multicenter Collaborative Biomarker Study (CBS). Two hundred and thirty-two formalin-fixed, paraffin-embedded breast cancer tissues and local laboratory HER2 testing results were provided by 11 CBS sites. HERmark assay and central laboratory HER2 IHC retesting were retrospectively performed in a blinded fashion. HER2 results by all testing methods were obtained in 192 cases. HERmark yielded a continuum of total HER2 expression (H2T) ranging from 0.3 to 403 RF/mm2 (approximately 3 logs). The distribution of H2T levels correlated significantly (P<0.0001) with all routine HER2 testing results. The concordance of positive and negative values (equivocal cases excluded) between HERmark and routine HER2 testing was 84% for local IHC, 96% for central IHC, 85% for local FISH, and 84% for local HER2 status. OS analysis revealed a significant correlation of shorter OS with HER2 positivity by local IHC (HR=2.6, P=0.016), central IHC (HR=3.2, P=0.015), and HERmark (HR=5.1, P<0.0001) in this cohort of patients most of whom received no HER2-targeted therapy. The OS curve of discordant low (HER2 positive but H2T low, 10% of all cases) was aligned with concordant negative (HER2 negative and H2T low, HR=1.9, P=0.444), but showed a significantly longer OS than concordant positive (HER2 positive and H2T high, HR=0.31, P=0.024). Conversely, the OS curve of discordant high (HER2 negative but H2T high, 9% of all cases) was aligned with concordant positive (HR=0.41, P=0.105), but showed a significantly shorter OS than concordant

  20. Predictive testing for Huntington's disease: relationship with partners after testing.

    PubMed

    Decruyenaere, M; Evers-Kiebooms, G; Cloostermans, T; Boogaerts, A; Demyttenaere, K; Dom, R; Fryns, J P

    2004-01-01

    This study focuses on the partner relationship of tested persons, 5 years after their predictive test result for Huntington's disease (HD). We describe changes in marital status, quality of the relationship, and perceived changes in the relationship. Twenty-six carriers, 14 of their partners, 33 non-carriers, and 17 of their partners participated in the study. Qualitative and quantitative methods were used. For the majority of tested persons (about 70%), the marital status was unchanged 5 years post test. Overall, carriers rated the quality of the relationship higher than their partners did and they perceived more positive changes. Qualitative data show that a test result leading to changed roles may induce significant marital distress. Another consequence of the test may be the changes in dynamics in asymptomatic carrier couples. A pre-test discussion of the possible impact of the test result on the relationship should result in a better preparation for and more understanding of the reactions after testing. Counselling after testing should stimulate an open communication between partners with consideration of needs and anxieties of both partners.

  1. Quantitative ptychographic reconstruction by applying a probe constraint

    NASA Astrophysics Data System (ADS)

    Reinhardt, J.; Schroer, C. G.

    2018-04-01

    The coherent scanning technique X-ray ptychography has become a routine tool for high-resolution imaging and nanoanalysis in various fields of research such as chemistry, biology or materials science. Often the ptychographic reconstruction results are analysed in order to yield absolute quantitative values for the object transmission and illuminating probe function. In this work, we address a common ambiguity encountered in scaling the object transmission and probe intensity via the application of an additional constraint to the reconstruction algorithm. A ptychographic measurement of a model sample containing nanoparticles is used as a test data set against which to benchmark in the reconstruction results depending on the type of constraint used. Achieving quantitative absolute values for the reconstructed object transmission is essential for advanced investigation of samples that are changing over time, e.g., during in-situ experiments or in general when different data sets are compared.

  2. Determination of a quantitative parameter to evaluate swimming technique based on the maximal tethered swimming test.

    PubMed

    Soncin, Rafael; Mezêncio, Bruno; Ferreira, Jacielle Carolina; Rodrigues, Sara Andrade; Huebner, Rudolf; Serrão, Julio Cerca; Szmuchrowski, Leszek

    2017-06-01

    The aim of this study was to propose a new force parameter, associated with swimmers' technique and performance. Twelve swimmers performed five repetitions of 25 m sprint crawl and a tethered swimming test with maximal effort. The parameters calculated were: the mean swimming velocity for crawl sprint, the mean propulsive force of the tethered swimming test as well as an oscillation parameter calculated from force fluctuation. The oscillation parameter evaluates the force variation around the mean force during the tethered test as a measure of swimming technique. Two parameters showed significant correlations with swimming velocity: the mean force during the tethered swimming (r = 0.85) and the product of the mean force square root and the oscillation (r = 0.86). However, the intercept coefficient was significantly different from zero only for the mean force, suggesting that although the correlation coefficient of the parameters was similar, part of the mean velocity magnitude that was not associated with the mean force was associated with the product of the mean force square root and the oscillation. Thus, force fluctuation during tethered swimming can be used as a quantitative index of swimmers' technique.

  3. Test Results for Entry Guidance Methods for Reusable Launch Vehicles

    NASA Technical Reports Server (NTRS)

    Hanson, John M.; Jones, Robert E.

    2003-01-01

    There are a number of approaches to advanced guidance and control (AG&C) that have the potential for achieving the goals of significantly increasing reusable launch vehicle (RLV) safety and reliability, and reducing the cost. This paper examines some approaches to entry guidance. An effort called Integration and Testing of Advanced Guidance and Control Technologies (ITAGCT) has recently completed a rigorous testing phase where these algorithms faced high-fidelity vehicle models and were required to perform a variety of representative tests. The algorithm developers spent substantial effort improving the algorithm performance in the testing. This paper lists the test cases used to demonstrate that the desired results are achieved, shows an automated test scoring method that greatly reduces the evaluation effort required, and displays results of the tests. Results show a significant improvement over previous guidance approaches. The two best-scoring algorithm approaches show roughly equivalent results and are ready to be applied to future reusable vehicle concepts.

  4. Quantitative photoacoustic elasticity and viscosity imaging for cirrhosis detection

    NASA Astrophysics Data System (ADS)

    Wang, Qian; Shi, Yujiao; Yang, Fen; Yang, Sihua

    2018-05-01

    Elasticity and viscosity assessments are essential for understanding and characterizing the physiological and pathological states of tissue. In this work, by establishing a photoacoustic (PA) shear wave model, an approach for quantitative PA elasticity imaging based on measurement of the rise time of the thermoelastic displacement was developed. Thus, using an existing PA viscoelasticity imaging method that features a phase delay measurement, quantitative PA elasticity imaging and viscosity imaging can be obtained in a simultaneous manner. The method was tested and validated by imaging viscoelastic agar phantoms prepared at different agar concentrations, and the imaging data were in good agreement with rheometry results. Ex vivo experiments on liver pathological models demonstrated the capability for cirrhosis detection, and the results were consistent with the corresponding histological results. This method expands the scope of conventional PA imaging and has potential to become an important alternative imaging modality.

  5. Limits of quantitation - Yet another suggestion

    NASA Astrophysics Data System (ADS)

    Carlson, Jill; Wysoczanski, Artur; Voigtman, Edward

    2014-06-01

    The work presented herein suggests that the limit of quantitation concept may be rendered substantially less ambiguous and ultimately more useful as a figure of merit by basing it upon the significant figure and relative measurement error ideas due to Coleman, Auses and Gram, coupled with the correct instantiation of Currie's detection limit methodology. Simple theoretical results are presented for a linear, univariate chemical measurement system with homoscedastic Gaussian noise, and these are tested against both Monte Carlo computer simulations and laser-excited molecular fluorescence experimental results. Good agreement among experiment, theory and simulation is obtained and an easy extension to linearly heteroscedastic Gaussian noise is also outlined.

  6. Correlation between caloric and ocular vestibular evoked myogenic potential test results.

    PubMed

    Huang, Chi-Hsuan; Wang, Shou-Jen; Young, Yi-Ho

    2012-02-01

    The ocular vestibular evoked myogenic potential (o-VEMP) test results correlate significantly with caloric test results for patients with acoustic neuroma (AN), but not for patients with Meniere's disease (MD), indicating that the o-VEMP test may replace the caloric test for evaluating the vestibular nerve from which the AN arises. Conversely, the caloric, o-VEMP, and cervical VEMP (c-VEMP) tests should be performed to map lesion sites in the vestibular labyrinth. This study performed caloric, o-VEMP, and c-VEMP tests on patients with central and peripheral vestibular disorders to investigate their relationships. In all, 66 patients comprising 16 with unilateral AN and 50 with unilateral definite MD were enrolled. All patients underwent caloric, o-VEMP, and c-VEMP tests. In the AN group, the caloric test identified canal paresis and caloric areflexia in 10 ears, while the o-VEMP and c-VEMP tests identified abnormal (absent or delayed) responses in 12 and 11 ears, respectively. A significant correlation existed between caloric and o-VEMP test results, but not between caloric and c-VEMP test results, or between o-VEMP and c-VEMP test results. For the MD group, abnormal caloric, o-VEMP, and c-VEMP test results were obtained for 24%, 44%, and 38% of hydropic ears, respectively. No correlation existed between any two test results.

  7. "We'll call you when the results are in": Preferences for how medical test results are delivered.

    PubMed

    Dooley, Michael D; Burreal, Shay; Sweeny, Kate

    2017-02-01

    Whether healthy or sick, adults undergo frequent medical testing; however, no guidelines currently exist as to how patients are informed of their medical test results. This short report provides an initial look at how healthcare professionals deliver medical test results and patient preferences regarding these procedures. We specifically focus on two options for delivery of results: (1) open-ended timing, in which patients are contacted without warning when test results become available; or (2) closed-ended timing, in which patients are provided with a specific day and time when they will learn their test results. Participants who underwent a recent medical test indicated which delivery method their healthcare professional provided and their preferred method. Findings demonstrate a large discrepancy between actual and preferred timing, stemming from a general trend towards providing open-ended timing, whereas patient preferences were evenly split between the two options. This study provides a first step in understanding the merits of two options for delivering medical test results to patients and suggests an opportunity to improve patient care. The findings from this study provide first steps toward the development of guidelines for delivering test results in ways that maximize the quality of patient care. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. 40 CFR 86.609-98 - Calculation and reporting of test results.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... results. 86.609-98 Section 86.609-98 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED....609-98 Calculation and reporting of test results. (a) Initial test results are calculated following the test procedures specified in § 86.608-98(a). Round the initial test results to the number of...

  9. Could Daylight Glare Be Defined Mathematically?Results of Testing the DGIN Method in Japan

    NASA Astrophysics Data System (ADS)

    Nazzal, Ali; Oki, Masato

    Discomfort glare from daylight is a common problem without valid prediction methods so far. A new mathematical DGIN (New Daylight Glare Index) method tries to respond the challenge. This paper reports on experiments carried out in daylit office environment in Japan to test applicability of the method. Slight positive correlation was found between the DGIN and the subjective evaluation. Additionally, a high Ladaptation value together with the small ratio of Lwindow to Ladaptation was obviously experienced sufficient to neutralize the effect of glare discomfort. However, subjective assessments are poor glare indicators and not reliable in testing glare prediction methods. DGIN is a good indicator of daylight glare, and when the DGIN value is analyzed together with the measured illuminance ratios, discomfort glare from daylight can be analyzed in a quantitative manner. The DGIN method could serve architects and lighting designers in testing daylighting systems, and also guide the action of daylight responsive lighting controls.

  10. A novel multi-walled carbon nanotube-based antibody conjugate for quantitative and semi-quantitative lateral flow assays.

    PubMed

    Sun, Wenjuan; Hu, Xiaolong; Liu, Jia; Zhang, Yurong; Lu, Jianzhong; Zeng, Libo

    2017-10-01

    In this study, the multi-walled carbon nanotubes (MWCNTs) were applied in lateral flow strips (LFS) for semi-quantitative and quantitative assays. Firstly, the solubility of MWCNTs was improved using various surfactants to enhance their biocompatibility for practical application. The dispersed MWCNTs were conjugated with the methamphetamine (MET) antibody in a non-covalent manner and then manufactured into the LFS for the quantitative detection of MET. The MWCNTs-based lateral flow assay (MWCNTs-LFA) exhibited an excellent linear relationship between the values of test line and MET when its concentration ranges from 62.5 to 1500 ng/mL. The sensitivity of the LFS was evaluated by conjugating MWCNTs with HCG antibody and the MWCNTs conjugated method is 10 times more sensitive than the one conjugated with classical colloidal gold nanoparticles. Taken together, our data demonstrate that MWCNTs-LFA is a more sensitive and reliable assay for semi-quantitative and quantitative detection which can be used in forensic analysis.

  11. Sarcoidosis: correlation of pulmonary parenchymal pattern at CT with results of pulmonary function tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bergin, C.J.; Bell, D.Y.; Coblentz, C.L.

    1989-06-01

    The appearances of the lungs on radiographs and computed tomographic (CT) scans were correlated with degree of uptake on gallium scans and results of pulmonary function tests (PFTs) in 27 patients with sarcoidosis. CT scans were evaluated both qualitatively and quantitatively. Patients were divided into five categories on the basis of the pattern of abnormality at CT: 1 = normal (n = 4); 2 = segmental air-space disease (n = 4); 3 = spherical (alveolar) masslike opacities (n = 4); 4 = multiple, discrete, small nodules (n = 6); and 5 = distortion of parenchymal structures (fibrotic end-stage sarcoidosis) (nmore » = 9). The percentage of the volume judged to be abnormal (CT grade) was correlated with PFT results for each CT and radiographic category. CT grades were also correlated with gallium scanning results and percentage of lymphocytes recovered from bronchoalveolar lavage (BAL). Patients in CT categories 1 and 2 had normal lung function, those in category 3 had mild functional impairment, and those in categories 4 and 5 showed moderate to severe dysfunction. The overall CT grade correlated well with PFT results expressed as a percentage of the predicted value. In five patients, CT scans showed extensive parenchymal disease not seen on radiographs. CT grades did not correlate with the results of gallium scanning or BAL lymphocytes. The authors conclude that patterns of parenchymal sarcoidosis seen at CT correlate with the PFT results and can be used to indicate respiratory impairment.« less

  12. Test results of a shower water recovery system

    NASA Technical Reports Server (NTRS)

    Verostko, Charles E.; Price, Donald F.; Garcia, Rafael; Pierson, Duane L.; Sauer, Richard L.

    1987-01-01

    A shower test was conducted recently at NASA-JSC in which waste water was reclaimed and reused. Test subjects showered in a prototype whole body shower following a protocol similar to that anticipated for Space Station. The waste water was purified using reverse osmosis followed by filtration through activated carbon and ion exchange resin beds. The reclaimed waste water was maintained free of microorganisms by using both heat and iodine. This paper discusses the test results, including the limited effectiveness of using iodine as a disinfectant and the evaluation of a Space Station candidate soap for showering. In addition, results are presented on chemical and microbial impurity content of water samples obtained from various locations in the water recovery process.

  13. Cost and Efficacy Assessment of an Alternative Medication Compliance Urine Drug Testing Strategy.

    PubMed

    Doyle, Kelly; Strathmann, Frederick G

    2017-02-01

    This study investigates the frequency at which quantitative results provide additional clinical benefit compared to qualitative results alone. A comparison between alternative urine drug screens and conventional screens including the assessment of cost-to-payer differences, accuracy of prescription compliance or polypharmacy/substance abuse was also included. In a reference laboratory evaluation of urine specimens from across the United States, 213 urine specimens with provided prescription medication information (302 prescriptions) were analyzed by two testing algorithms: 1) conventional immunoassay screen with subsequent reflexive testing of positive results by quantitative mass spectrometry; and 2) a combined immunoassay/qualitative mass-spectrometry screen that substantially reduced the need for subsequent testing. The qualitative screen was superior to immunoassay with reflex to mass spectrometry in confirming compliance per prescription (226/302 vs 205/302), and identifying non-prescription abuse (97 vs 71). Pharmaceutical impurities and inconsistent drug metabolite patterns were detected in only 3.8% of specimens, suggesting that quantitative results have limited benefit. The percentage difference between the conventional testing algorithm and the alternative screen was projected to be 55%, and a 2-year evaluation of test utilization as a measure of test order volume follows an exponential trend for alternative screen test orders over conventional immunoassay screens that require subsequent confirmation testing. Alternative, qualitative urine drug screens provide a less expensive, faster, and more comprehensive evaluation of patient medication compliance and drug abuse. The vast majority of results were interpretable with qualitative results alone indicating a reduced need to automatically reflex to quantitation or provide quantitation for the majority of patients. This strategy highlights a successful approach using an alternative strategy for both the

  14. Qualitative, semi-quantitative, and quantitative simulation of the osmoregulation system in yeast

    PubMed Central

    Pang, Wei; Coghill, George M.

    2015-01-01

    In this paper we demonstrate how Morven, a computational framework which can perform qualitative, semi-quantitative, and quantitative simulation of dynamical systems using the same model formalism, is applied to study the osmotic stress response pathway in yeast. First the Morven framework itself is briefly introduced in terms of the model formalism employed and output format. We then built a qualitative model for the biophysical process of the osmoregulation in yeast, and a global qualitative-level picture was obtained through qualitative simulation of this model. Furthermore, we constructed a Morven model based on existing quantitative model of the osmoregulation system. This model was then simulated qualitatively, semi-quantitatively, and quantitatively. The obtained simulation results are presented with an analysis. Finally the future development of the Morven framework for modelling the dynamic biological systems is discussed. PMID:25864377

  15. The Space Station Photovoltaic Panels Plasma Interaction Test Program: Test plan and results

    NASA Technical Reports Server (NTRS)

    Nahra, Henry K.; Felder, Marian C.; Sater, Bernard L.; Staskus, John V.

    1989-01-01

    The Plasma Interaction Test performed on two space station solar array panels is addressed. This includes a discussion of the test requirements, test plan, experimental set-up, and test results. It was found that parasitic current collection was insignificant (0.3 percent of the solar array delivered power). The measured arcing threshold ranged from -210 to -457 V with respect to the plasma potential. Furthermore, the dynamic response of the panels showed the panel time constant to range between 1 and 5 microsec, and the panel capacitance to be between .01 and .02 microF.

  16. The Space Station photovoltaic panels plasma interaction test program - Test plan and results

    NASA Technical Reports Server (NTRS)

    Nahra, Henry K.; Felder, Marian C.; Sater, Bernard L.; Staskus, John V.

    1990-01-01

    The plasma Interaction Test performed on two space station solar array panels is addressed. This includes a discussion of the test requirements, test plan, experimental set-up, and test results. It was found that parasitic current collection was insignificant (0.3 percent of the solar array delivered power). The measured arcing threshold ranged from -210 to -457 V with respect to the plasma potential. Furthermore, the dynamic response of the panels showed the panel time constant to range between 1 and 5 microsec, and the panel capacitance to be between .01 and .02 microF.

  17. The efficacy of semi-quantitative urine protein-to-creatinine (P/C) ratio for the detection of significant proteinuria in urine specimens in health screening settings.

    PubMed

    Chang, Chih-Chun; Su, Ming-Jang; Ho, Jung-Li; Tsai, Yu-Hui; Tsai, Wei-Ting; Lee, Shu-Jene; Yen, Tzung-Hai; Chu, Fang-Yeh

    2016-01-01

    Urine protein detection could be underestimated using the conventional dipstick method because of variations in urine aliquots. This study aimed to assess the efficacy of the semi-quantitative urine protein-to-creatinine (P/C) ratio compared with other laboratory methods. Random urine samples were requested from patients undergoing chronic kidney disease screening. Significant proteinuria was determined by the quantitative P/C ratio of at least 150 mg protein/g creatinine. The semi-quantitative P/C ratio, dipstick protein and quantitative protein concentrations were compared and analyzed. In the 2932 urine aliquots, 156 (5.3 %) urine samples were considered as diluted and 60 (39.2 %) were found as significant proteinuria. The semi-quantitative P/C ratio testing had the best sensitivity (70.0 %) and specificity (95.9 %) as well as the lowest underestimation rate (0.37 %) when compared to other laboratory methods in the study. In the semi-quantitative P/C ratio test, 19 (12.2 %) had positive, 52 (33.3 %) had diluted, and 85 (54.5 %) had negative results. Of those with positive results, 7 (36.8 %) were positive detected by traditional dipstick urine protein test, and 9 (47.4 %) were positive detected by quantitative urine protein test. Additionally, of those with diluted results, 25 (48.1 %) had significant proteinuria, and all were assigned as no significant proteinuria by both tests. The semi-quantitative urine P/C ratio is clinically applicable based on its better sensitivity and screening ability for significant proteinuria than other laboratory methods, particularly in diluted urine samples. To establish an effective strategy for CKD prevention, urine protein screening with semi-quantitative P/C ratio could be considered.

  18. 40 CFR 211.212-5 - Reporting of test results.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Reporting of test results. 211.212-5 Section 211.212-5 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS PRODUCT NOISE LABELING Hearing Protective Devices § 211.212-5 Reporting of test results. (a)(1...

  19. 40 CFR 211.212-5 - Reporting of test results.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Reporting of test results. 211.212-5 Section 211.212-5 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS PRODUCT NOISE LABELING Hearing Protective Devices § 211.212-5 Reporting of test results. (a)(1...

  20. 40 CFR 211.212-5 - Reporting of test results.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Reporting of test results. 211.212-5 Section 211.212-5 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS PRODUCT NOISE LABELING Hearing Protective Devices § 211.212-5 Reporting of test results. (a)(1...

  1. 40 CFR 211.212-5 - Reporting of test results.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Reporting of test results. 211.212-5 Section 211.212-5 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS PRODUCT NOISE LABELING Hearing Protective Devices § 211.212-5 Reporting of test results. (a)(1...

  2. 40 CFR 211.212-5 - Reporting of test results.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Reporting of test results. 211.212-5 Section 211.212-5 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS PRODUCT NOISE LABELING Hearing Protective Devices § 211.212-5 Reporting of test results. (a)(1...

  3. Quantitative evaluation research of glare from automotive headlamps

    NASA Astrophysics Data System (ADS)

    Wang, Tiecheng; Qian, Rui; Cao, Ye; Gao, Mingqiu

    2018-01-01

    This study concerns the quantized evaluation research of glare from automotive headlamps. In the actual regulations, only one point in the test screen is set for judging whether driver can bear the light caused by headlamps of opposing vehicle. To evaluating practical effect of glare, we accept a glare zone with the probability distribution information of the oncoming driver's eye position. In this focus area, glare level of headlamp is represented by weighted luminous flux. To confirm the most comfortable illuminance value to human eyes at 50 m, we used test point B50L as observation position, and collected 1,000 subjective evaluation data from 20 test personnel in different ages during two months. Basing on the assessment results, we calculated 0.60 lx as recommended value for standardized testing procedure at 25 m. Then we figured out 0.38 lm as optimum value, and 0.25 / 1.20 lm as limiting values depending on regulations. We tested 40 sample vehicles with different levels to verify the sectional nonlinear quantitative evaluation method we designed, and analyzed the typical test results.

  4. 40 CFR 86.609-98 - Calculation and reporting of test results.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... results. 86.609-98 Section 86.609-98 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Vehicles § 86.609-98 Calculation and reporting of test results. (a) Initial test results are calculated following the test procedures specified in § 86.608-98(a). Round the initial test results to the number of...

  5. 40 CFR 86.609-98 - Calculation and reporting of test results.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... results. 86.609-98 Section 86.609-98 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Vehicles § 86.609-98 Calculation and reporting of test results. (a) Initial test results are calculated following the test procedures specified in § 86.608-98(a). Round the initial test results to the number of...

  6. Quantitative CT analysis of honeycombing area in idiopathic pulmonary fibrosis: Correlations with pulmonary function tests.

    PubMed

    Nakagawa, Hiroaki; Nagatani, Yukihiro; Takahashi, Masashi; Ogawa, Emiko; Tho, Nguyen Van; Ryujin, Yasushi; Nagao, Taishi; Nakano, Yasutaka

    2016-01-01

    The 2011 official statement of idiopathic pulmonary fibrosis (IPF) mentions that the extent of honeycombing and the worsening of fibrosis on high-resolution computed tomography (HRCT) in IPF are associated with the increased risk of mortality. However, there are few reports about the quantitative computed tomography (CT) analysis of honeycombing area. In this study, we first proposed a computer-aided method for quantitative CT analysis of honeycombing area in patients with IPF. We then evaluated the correlations between honeycombing area measured by the proposed method with that estimated by radiologists or with parameters of PFTs. Chest HRCTs and pulmonary function tests (PFTs) of 36 IPF patients, who were diagnosed using HRCT alone, were retrospectively evaluated. Two thoracic radiologists independently estimated the honeycombing area as Identified Area (IA) and the percentage of honeycombing area to total lung area as Percent Area (PA) on 3 axial CT slices for each patient. We also developed a computer-aided method to measure the honeycombing area on CT images of those patients. The total honeycombing area as CT honeycombing area (HA) and the percentage of honeycombing area to total lung area as CT %honeycombing area (%HA) were derived from the computer-aided method for each patient. HA derived from three CT slices was significantly correlated with IA (ρ=0.65 for Radiologist 1 and ρ=0.68 for Radiologist 2). %HA derived from three CT slices was also significantly correlated with PA (ρ=0.68 for Radiologist 1 and ρ=0.70 for Radiologist 2). HA and %HA derived from all CT slices were significantly correlated with FVC (%pred.), DLCO (%pred.), and the composite physiologic index (CPI) (HA: ρ=-0.43, ρ=-0.56, ρ=0.63 and %HA: ρ=-0.60, ρ=-0.49, ρ=0.69, respectively). The honeycombing area measured by the proposed computer-aided method was correlated with that estimated by expert radiologists and with parameters of PFTs. This quantitative CT analysis of

  7. Results of Studying Astronomy Students’ Science Literacy, Quantitative Literacy, and Information Literacy

    NASA Astrophysics Data System (ADS)

    Buxner, Sanlyn; Impey, Chris David; Follette, Katherine B.; Dokter, Erin F.; McCarthy, Don; Vezino, Beau; Formanek, Martin; Romine, James M.; Brock, Laci; Neiberding, Megan; Prather, Edward E.

    2017-01-01

    Introductory astronomy courses often serve as terminal science courses for non-science majors and present an opportunity to assess non future scientists’ attitudes towards science as well as basic scientific knowledge and scientific analysis skills that may remain unchanged after college. Through a series of studies, we have been able to evaluate students’ basic science knowledge, attitudes towards science, quantitative literacy, and informational literacy. In the Fall of 2015, we conducted a case study of a single class administering all relevant surveys to an undergraduate class of 20 students. We will present our analysis of trends of each of these studies as well as the comparison case study. In general we have found that students basic scientific knowledge has remained stable over the past quarter century. In all of our studies, there is a strong relationship between student attitudes and their science and quantitative knowledge and skills. Additionally, students’ information literacy is strongly connected to their attitudes and basic scientific knowledge. We are currently expanding these studies to include new audiences and will discuss the implications of our findings for instructors.

  8. Relationship between substances in seminal plasma and Acrobeads Test results.

    PubMed

    Komori, Kazuhiko; Tsujimura, Akira; Okamoto, Yoshio; Matsuoka, Yasuhiro; Takao, Tetsuya; Miyagawa, Yasushi; Takada, Shingo; Nonomura, Norio; Okuyama, Akihiko

    2009-01-01

    To asses the effects of seminal plasma on sperm function. Retrospective case-control study. University hospital. One hundred fourteen infertile men. Acrobeads Test scores (0-4) and measurement of interleukin (IL)-6, soluble IL-6 receptor, epidermal growth factor, insulin-like growth factor-I (IGF-I), transforming growth factor-beta I, superoxide dismutase, calcitonin, and macrophage migration inhibitory factor (MIF) levels in seminal plasma. Kruskal-Wallis test to compare the concentrations of substances as a nonparametric test for differences among Acrobeads Test scores and a multivariable logistic regression model to find independent risk factors associated with abnormal Acrobeads Test results. The Acrobeads Test score was 0 for 7 samples, 1 for 20 samples, 2 for 18 samples, 3 for 28 samples, and 4 for 41 samples. Age, abstinence period, and semen parameters, except for sperm motility and percentage of sperm with abnormal morphology, had no effect on the Acrobeads Test results. Concentrations of IGF-I and MIF were significantly higher in patients with abnormal Acrobeads Test results. Multivariate analysis indicated that MIF and IGF-I were significantly associated with abnormal Acrobeads Test results (scores 0 to 1). Although further studies are needed, IGF-I and MIF in seminal plasma may have negative effects on sperm function.

  9. Recent Radiation Test Results for Power MOSFETs

    NASA Technical Reports Server (NTRS)

    Lauenstein, Jean-Marie; Topper, Alyson D.; Casey, Megan C.; Wilcox, Edward P.; Phan, Anthony M.; Kim, Hak S.; LaBel, Kenneth A.

    2013-01-01

    Single-event effect (SEE) and total ionizing dose (TID) test results are presented for various hardened and commercial power metal-oxide-semiconductor field effect transistors (MOSFETs), including vertical planar, trench, superjunction, and lateral process designs.

  10. 40 CFR 89.509 - Calculation and reporting of test results.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Calculation and reporting of test... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Selective Enforcement Auditing § 89.509 Calculation and reporting of test results. (a) Initial test results...

  11. Advancing the study of violence against women using mixed methods: integrating qualitative methods into a quantitative research program.

    PubMed

    Testa, Maria; Livingston, Jennifer A; VanZile-Tamsen, Carol

    2011-02-01

    A mixed methods approach, combining quantitative with qualitative data methods and analysis, offers a promising means of advancing the study of violence. Integrating semi-structured interviews and qualitative analysis into a quantitative program of research on women's sexual victimization has resulted in valuable scientific insight and generation of novel hypotheses for testing. This mixed methods approach is described and recommendations for integrating qualitative data into quantitative research are provided.

  12. [Comparison of the CMV antigenemia test and CMV-DNA PCR results in solid organ transplant recipients].

    PubMed

    Özkarata, Emre; Özkarataş, Emre; Özbek, Ö Alpay; Avkan Oğuz, Vildan; Sayıner, A Arzu

    2016-01-01

    Cytomegalovirus (CMV) infection is among the most common important viral infections in solid organ transplant (SOT) recipients. Diagnostic tests for detecting CMV replication are widely used for this group of patients, however there is no clear agreement on the cut-off levels for interpretation of clinical decisions especially when the low level of viral load is detected. In this study, CMV pp65 antigenemia test results were compared with plasma CMV-DNA levels detected by quantitative real-time polymerase chain reaction (qPCR) in samples of kidney and liver transplant recipients in the Central Laboratory of Dokuz Eylul University Hospital between 2011 and 2013, and the correlation between these two tests and viral load equivalent to antigenemia positivity were determined. In the study, pp65 antigenemia and CMV-DNA qPCR results were evaluated retrospectively. The samples from the same patients were included if the time between antigenemia and CMV-DNA qPCR tests were less than 48 hours. SPSS v15.0 was used for correlation, regression and ROC curve analysis. The results of the 217 samples collected from 100 patients (59 male, 41 female; age range: 16-71, mean age: 46 ± 13 years), 36 liver and 64 kidney recipients were evaluated in the study. Of the patients 80% were CMV IgM negative, IgG positive; 1% was CMV IgG and IgM positive; 2% were CMV IgM and IgG negative, while for 17 patients serological results could not be reached. CMV pp65 antigenemia and CMV-DNA were both negative in 102 (47%) samples, while both were positive in 37 (17%) samples. The single sample from a case with CMV IgM and IgG positivity yielded negative results for both antigenemia and CMV-DNA tests. In 78 samples antigenemia were negative and CMV-DNA qPCR were positive, while there were no samples with antigenemia positive and qPCR negative. Mean values of antigenemia and qPCR tests were 23 positive cells/200.000 leukocytes (range: 1 to 230 positive cells) and 12.595 copies/ml (range: 180 to 106

  13. Testing decision rules for categorizing species' extinction risk to help develop quantitative listing criteria for the U.S. Endangered Species Act.

    PubMed

    Regan, Tracey J; Taylor, Barbara L; Thompson, Grant G; Cochrane, Jean Fitts; Ralls, Katherine; Runge, Michael C; Merrick, Richard

    2013-08-01

    Lack of guidance for interpreting the definitions of endangered and threatened in the U.S. Endangered Species Act (ESA) has resulted in case-by-case decision making leaving the process vulnerable to being considered arbitrary or capricious. Adopting quantitative decision rules would remedy this but requires the agency to specify the relative urgency concerning extinction events over time, cutoff risk values corresponding to different levels of protection, and the importance given to different types of listing errors. We tested the performance of 3 sets of decision rules that use alternative functions for weighting the relative urgency of future extinction events: a threshold rule set, which uses a decision rule of x% probability of extinction over y years; a concave rule set, where the relative importance of future extinction events declines exponentially over time; and a shoulder rule set that uses a sigmoid shape function, where relative importance declines slowly at first and then more rapidly. We obtained decision cutoffs by interviewing several biologists and then emulated the listing process with simulations that covered a range of extinction risks typical of ESA listing decisions. We evaluated performance of the decision rules under different data quantities and qualities on the basis of the relative importance of misclassification errors. Although there was little difference between the performance of alternative decision rules for correct listings, the distribution of misclassifications differed depending on the function used. Misclassifications for the threshold and concave listing criteria resulted in more overprotection errors, particularly as uncertainty increased, whereas errors for the shoulder listing criteria were more symmetrical. We developed and tested the framework for quantitative decision rules for listing species under the U.S. ESA. If policy values can be agreed on, use of this framework would improve the implementation of the ESA by

  14. Flexor and extensor muscle tone evaluated using the quantitative pendulum test in stroke and parkinsonian patients.

    PubMed

    Huang, Han-Wei; Ju, Ming-Shaung; Lin, Chou-Ching K

    2016-05-01

    The aim of this study was to evaluate the flexor and extensor muscle tone of the upper limbs in patients with spasticity or rigidity and to investigate the difference in hypertonia between spasticity and rigidity. The two experimental groups consisted of stroke patients and parkinsonian patients. The control group consisted of age and sex-matched normal subjects. Quantitative upper limb pendulum tests starting from both flexed and extended joint positions were conducted. System identification with a simple linear model was performed and model parameters were derived. The differences between the three groups and two starting positions were investigated by these model parameters and tested by two-way analysis of variance. In total, 57 subjects were recruited, including 22 controls, 14 stroke patients and 21 parkinsonian patients. While stiffness coefficient showed no difference among groups, the number of swings, relaxation index and damping coefficient showed changes suggesting significant hypertonia in the two patient groups. There was no difference between these two patient groups. The test starting from the extended position constantly manifested higher muscle tone in all three groups. In conclusion, the hypertonia of parkinsonian and stroke patients could not be differentiated by the modified pendulum test; the elbow extensors showed a higher muscle tone in both control and patient groups; and hypertonia of both parkinsonian and stroke patients is velocity dependent. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Vision, Training Hours, and Road Testing Results in Bioptic Drivers

    PubMed Central

    Dougherty, Bradley E.; Flom, Roanne E.; Bullimore, Mark A.; Raasch, Thomas W.

    2015-01-01

    Purpose Bioptic telescopic spectacles (BTS) can be used by people with central visual acuity that does not meet the state standards to obtain an unrestricted driver’s license. The purpose of this study was to examine the relationships among visual and demographic factors, training hours, and the results of road testing for bioptic drivers. Methods A retrospective study of patients who received an initial daylight bioptic examination at the Ohio State University and subsequently received a bioptic license was conducted. Data were collected on vision including visual acuity, contrast sensitivity, and visual field. Hours of driver training and results of Highway Patrol road testing were extracted from records. Relationships among vision, training hours, and road testing were analyzed. Results Ninety-seven patients who completed a vision examination between 2004 and 2008 and received daylight licensure with BTS were included. Results of the first Highway Patrol road test were available for 74 patients. The median interquartile range (IQR) hours of training prior to road testing was 21±17 hours, (range of 9 to 75 hours). Candidates without previous licensure were younger (p< 0.001) and had more documented training (p< 0.001). Lack of previous licensure and more training were significantly associated with having failed a portion of the Highway Patrol test and points deducted on the road test. Conclusions New bioptic drivers without previous non-bioptic driving experience required more training and performed more poorly on road testing for licensure than those who had previous non-bioptic licensure. No visual factor was predictive of road testing results after adjustment for previous experience. The hours of training received remained predictive of road testing outcome even with adjustment for previous experience. These results suggest that previous experience and trainer assessments should be investigated as potential predictors of road safety in bioptic drivers in

  16. Multicomponent quantitative spectroscopic analysis without reference substances based on ICA modelling.

    PubMed

    Monakhova, Yulia B; Mushtakova, Svetlana P

    2017-05-01

    A fast and reliable spectroscopic method for multicomponent quantitative analysis of targeted compounds with overlapping signals in complex mixtures has been established. The innovative analytical approach is based on the preliminary chemometric extraction of qualitative and quantitative information from UV-vis and IR spectral profiles of a calibration system using independent component analysis (ICA). Using this quantitative model and ICA resolution results of spectral profiling of "unknown" model mixtures, the absolute analyte concentrations in multicomponent mixtures and authentic samples were then calculated without reference solutions. Good recoveries generally between 95% and 105% were obtained. The method can be applied to any spectroscopic data that obey the Beer-Lambert-Bouguer law. The proposed method was tested on analysis of vitamins and caffeine in energy drinks and aromatic hydrocarbons in motor fuel with 10% error. The results demonstrated that the proposed method is a promising tool for rapid simultaneous multicomponent analysis in the case of spectral overlap and the absence/inaccessibility of reference materials.

  17. Qualitative, semi-quantitative, and quantitative simulation of the osmoregulation system in yeast.

    PubMed

    Pang, Wei; Coghill, George M

    2015-05-01

    In this paper we demonstrate how Morven, a computational framework which can perform qualitative, semi-quantitative, and quantitative simulation of dynamical systems using the same model formalism, is applied to study the osmotic stress response pathway in yeast. First the Morven framework itself is briefly introduced in terms of the model formalism employed and output format. We then built a qualitative model for the biophysical process of the osmoregulation in yeast, and a global qualitative-level picture was obtained through qualitative simulation of this model. Furthermore, we constructed a Morven model based on existing quantitative model of the osmoregulation system. This model was then simulated qualitatively, semi-quantitatively, and quantitatively. The obtained simulation results are presented with an analysis. Finally the future development of the Morven framework for modelling the dynamic biological systems is discussed. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  18. The Quantitative Science of Evaluating Imaging Evidence.

    PubMed

    Genders, Tessa S S; Ferket, Bart S; Hunink, M G Myriam

    2017-03-01

    Cardiovascular diagnostic imaging tests are increasingly used in everyday clinical practice, but are often imperfect, just like any other diagnostic test. The performance of a cardiovascular diagnostic imaging test is usually expressed in terms of sensitivity and specificity compared with the reference standard (gold standard) for diagnosing the disease. However, evidence-based application of a diagnostic test also requires knowledge about the pre-test probability of disease, the benefit of making a correct diagnosis, the harm caused by false-positive imaging test results, and potential adverse effects of performing the test itself. To assist in clinical decision making regarding appropriate use of cardiovascular diagnostic imaging tests, we reviewed quantitative concepts related to diagnostic performance (e.g., sensitivity, specificity, predictive values, likelihood ratios), as well as possible biases and solutions in diagnostic performance studies, Bayesian principles, and the threshold approach to decision making. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. Overview of classical test theory and item response theory for the quantitative assessment of items in developing patient-reported outcomes measures.

    PubMed

    Cappelleri, Joseph C; Jason Lundy, J; Hays, Ron D

    2014-05-01

    The US Food and Drug Administration's guidance for industry document on patient-reported outcomes (PRO) defines content validity as "the extent to which the instrument measures the concept of interest" (FDA, 2009, p. 12). According to Strauss and Smith (2009), construct validity "is now generally viewed as a unifying form of validity for psychological measurements, subsuming both content and criterion validity" (p. 7). Hence, both qualitative and quantitative information are essential in evaluating the validity of measures. We review classical test theory and item response theory (IRT) approaches to evaluating PRO measures, including frequency of responses to each category of the items in a multi-item scale, the distribution of scale scores, floor and ceiling effects, the relationship between item response options and the total score, and the extent to which hypothesized "difficulty" (severity) order of items is represented by observed responses. If a researcher has few qualitative data and wants to get preliminary information about the content validity of the instrument, then descriptive assessments using classical test theory should be the first step. As the sample size grows during subsequent stages of instrument development, confidence in the numerical estimates from Rasch and other IRT models (as well as those of classical test theory) would also grow. Classical test theory and IRT can be useful in providing a quantitative assessment of items and scales during the content-validity phase of PRO-measure development. Depending on the particular type of measure and the specific circumstances, the classical test theory and/or the IRT should be considered to help maximize the content validity of PRO measures. Copyright © 2014 Elsevier HS Journals, Inc. All rights reserved.

  20. Update on results of SPRE testing at NASA Lewis

    NASA Technical Reports Server (NTRS)

    Cairelli, James E.; Swec, Diane M.; Wong, Wayne A.; Doeberling, Thomas J.; Madi, Frank J.

    1991-01-01

    The Space Power Research Engine (SPRE), a free-piston Stirling engine with a linear alternator, is being tested at NASA Lewis Research Center as part of the Civilian Space Technology Initiative (CSTI) as a candidate for high capacity space power. Results are presented from recent SPRE tests designed to investigated the effects of variation in the displacer seal clearance and piston centering port area on engine performance and dynamics. The impact of these variations on PV power and efficiency are presented. Comparisons of the displacer seal clearance tests results with HFAST code predictions show good agreement for PV power, but show poor agreement for PV efficiency. Correlations are presented relating the piston midstroke position to the dynamic Delta P across the piston and the centering port area. Test results indicate that a modest improvement in PV power and efficiency may be realized with a reduction in piston centering port area.

  1. Update on results of SPRE testing at NASA Lewis

    NASA Technical Reports Server (NTRS)

    Cairelli, James E.; Swec, Diane M.; Wong, Wayne A.; Doeberling, Thomas J.; Madi, Frank J.

    1991-01-01

    The Space Power Research Engine (SPRE), a free-piston Stirling engine with a linear alternator, is being tested at NASA Lewis Research Center as part of the Civilian Space Technology Initiative (CSTI) as a candidate for high capacity space power. Results are presented from recent SPRE tests designed to investigate the effects of variation in the displacer seal clearance and piston centering port area on engine performance and dynamics. The effects of these variations on PV power and efficiency are presented. Comparisons of the displacer seal clearance test results with HFAST code predictions show good agreement for PV power but poor agreement for PV efficiency. Correlations are presented relating the piston mid-stroke position to the dynamic Delta P across the piston and the centering port area. Test results indicate that a modest improvement in PV power and efficiency may be realized with a reduction in piston centering port area.

  2. Quantitative evaluation of Alzheimer's disease

    NASA Astrophysics Data System (ADS)

    Duchesne, S.; Frisoni, G. B.

    2009-02-01

    We propose a single, quantitative metric called the disease evaluation factor (DEF) and assess its efficiency at estimating disease burden in normal, control subjects (CTRL) and probable Alzheimer's disease (AD) patients. The study group consisted in 75 patients with a diagnosis of probable AD and 75 age-matched normal CTRL without neurological or neuropsychological deficit. We calculated a reference eigenspace of MRI appearance from reference data, in which our CTRL and probable AD subjects were projected. We then calculated the multi-dimensional hyperplane separating the CTRL and probable AD groups. The DEF was estimated via a multidimensional weighted distance of eigencoordinates for a given subject and the CTRL group mean, along salient principal components forming the separating hyperplane. We used quantile plots, Kolmogorov-Smirnov and χ2 tests to compare the DEF values and test that their distribution was normal. We used a linear discriminant test to separate CTRL from probable AD based on the DEF factor, and reached an accuracy of 87%. A quantitative biomarker in AD would act as an important surrogate marker of disease status and progression.

  3. TEST RESULTS FOR FUEL-CELL OPERATION ON LANDFILL GAS

    EPA Science Inventory

    Test results from a demonstration of fuel-cell (FC) energy recovery and control of landfill gas emissions are presented. The project addressed two major issues: (i) the design, construction, and testing of a landfill-gas cleanup system; and (ii) a field test of a commercial phos...

  4. AOF: standalone test results of GALACSI

    NASA Astrophysics Data System (ADS)

    La Penna, P.; Aller Carpentier, E.; Argomedo, J.; Arsenault, R.; Conzelmann, R. D.; Delabre, B.; Donaldson, R.; Gago, F.; Gutierrez-Cheetam, P.; Hubin, N.; Jolley, P.; Kiekebusch, M.; Kirchbauer, J. P.; Klein, B.; Kolb, J.; Kuntschner, H.; Le Louarn, M.; Lizon, J.-L.; Madec, P.-Y.; Manescau, A.; Mehrgan, L.; Oberti, S.; Quentin, J.; Sedghi, B.; Ströbele, S.; Suárez Valles, M.; Soenke, C.; Tordo, S.; Vernet, J.

    2016-07-01

    GALACSI is the Adaptive Optics (AO) module that will serve the MUSE Integral Field Spectrograph. In Wide Field Mode it will enhance the collected energy in a 0.2"×0.2" pixel by a factor 2 at 750 nm over a Field of View (FoV) of 1'×1' using the Ground Layer AO (GLAO) technique. In Narrow Field Mode, it will provide a Strehl Ratio of 5% (goal 10%) at 650 nm, but in a smaller FoV (7.5"×7.5" FoV), using Laser Tomography AO (LTAO). Before being ready for shipping to Paranal, the system has gone through an extensive testing phase in Europe, first in standalone mode and then in closed loop with the DSM in Europe. After outlining the technical features of the system, we describe here the first part of that testing phase and the integration with the AOF ASSIST (Adaptive Secondary Setup and Instrument Stimulator) testbench, including a specific adapter for the IRLOS truth sensor. The procedures for the standalone verification of the main system performances are outlined, and the results of the internal functional tests of GALACSI after full integration and alignment on ASSIST are presented.

  5. Flight test results of riblets at supersonic speeds

    NASA Technical Reports Server (NTRS)

    Zuniga, Fanny A.; Anderson, Bianca T.; Bertelrud, Arild

    1992-01-01

    A flight experiment to test and evaluate the skin friction drag characteristics of a riblet surface in turbulent flow at supersonic speeds was conducted at NASA Dryden. Riblets of groove sizes 0.0030 and 0.0013 in. were mounted on the F-104G flight test fixture. The test surfaces were surveyed with boundary layer rakes and pressure orifices to examine the boundary layer profiles and pressure distributions of the flow. Skin friction reductions caused by the riblet surface were reported based on measured differences of momentum thickness between the smooth and riblet surfaces obtained from the boundary layer data. Flight test results for the 0.0030 in. riblet show skin friction reductions of 4 to 8 % for Mach numbers ranging from 1.2 to 1.6 and Reynolds numbers ranging from 2 to 3.4 million per unit foot. The results from the 0.0013 in. riblets show skin friction reductions of 4 to 15 % for Mach 1.2 to 1.4 and Reynolds numbers ranging from 3.6 to 6 million per unit foot.

  6. 40 CFR 90.509 - Calculation and reporting of test results.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... results. 90.509 Section 90.509 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Selective Enforcement Auditing § 90.509 Calculation and reporting of test results. (a) Initial test results... manufacturer shall round these results, in accordance with ASTM E29-93a, to the number of decimal places...

  7. 40 CFR 90.509 - Calculation and reporting of test results.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... results. 90.509 Section 90.509 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Selective Enforcement Auditing § 90.509 Calculation and reporting of test results. (a) Initial test results... manufacturer shall round these results, in accordance with ASTM E29-93a, to the number of decimal places...

  8. 40 CFR 90.509 - Calculation and reporting of test results.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... results. 90.509 Section 90.509 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Selective Enforcement Auditing § 90.509 Calculation and reporting of test results. (a) Initial test results... manufacturer shall round these results, in accordance with ASTM E29-93a, to the number of decimal places...

  9. Safety and Utility of Quantitative Sensory Testing among Adults with Sickle Cell Disease: Indicators of Neuropathic Pain?

    PubMed Central

    Ezenwa, Miriam O.; Molokie, Robert E.; Wang, Zaijie Jim; Yao, Yingwei; Suarez, Marie L.; Pullum, Cherese; Schlaeger, Judith M.; Fillingim, Roger B.; Wilkie, Diana J.

    2014-01-01

    Objectives Pain is the hallmark symptom of sickle cell disease (SCD), yet the types of pain that these patients experience, and the underlying mechanisms, have not been well characterized. The study purpose was to determine the safety and utility of a mechanical and thermal quantitative sensory testing (QST) protocol and the feasibility of utilizing neuropathic pain questionnaires among adults with SCD. Methods A convenience sample (N=25, 18 women, mean age 38.5 ± 12.5 [20–58 years]) completed self-report pain and quality-of-life tools. Subjects also underwent testing with the TSA-II NeuroSensory Analyzer and calibrated von Frey microfilaments. Results We found that the QST protocol was safe and did not stimulate a SCD pain crisis. There was evidence of central sensitization (n=15), peripheral sensitization (n=1), a mix of central and peripheral sensitization (n=8), or no sensitization (n=1). The neuropathic pain self-report tools were feasible with evidence of construct validity; 40% of the subjects reported S-LANSS scores that were indicative of neuropathic pain and had evidence of central, peripheral or mixed sensitization. Discussion The QST protocol can be safely conducted in adults with SCD and provides evidence of central or peripheral sensitization, which is consistent with a neuropathic component to SCD pain. These findings are novel, warrant a larger confirmatory study, and indicate the need for normative QST data from African American adults and older adults. PMID:25581383

  10. Immunochromatographic diagnostic test analysis using Google Glass.

    PubMed

    Feng, Steve; Caire, Romain; Cortazar, Bingen; Turan, Mehmet; Wong, Andrew; Ozcan, Aydogan

    2014-03-25

    We demonstrate a Google Glass-based rapid diagnostic test (RDT) reader platform capable of qualitative and quantitative measurements of various lateral flow immunochromatographic assays and similar biomedical diagnostics tests. Using a custom-written Glass application and without any external hardware attachments, one or more RDTs labeled with Quick Response (QR) code identifiers are simultaneously imaged using the built-in camera of the Google Glass that is based on a hands-free and voice-controlled interface and digitally transmitted to a server for digital processing. The acquired JPEG images are automatically processed to locate all the RDTs and, for each RDT, to produce a quantitative diagnostic result, which is returned to the Google Glass (i.e., the user) and also stored on a central server along with the RDT image, QR code, and other related information (e.g., demographic data). The same server also provides a dynamic spatiotemporal map and real-time statistics for uploaded RDT results accessible through Internet browsers. We tested this Google Glass-based diagnostic platform using qualitative (i.e., yes/no) human immunodeficiency virus (HIV) and quantitative prostate-specific antigen (PSA) tests. For the quantitative RDTs, we measured activated tests at various concentrations ranging from 0 to 200 ng/mL for free and total PSA. This wearable RDT reader platform running on Google Glass combines a hands-free sensing and image capture interface with powerful servers running our custom image processing codes, and it can be quite useful for real-time spatiotemporal tracking of various diseases and personal medical conditions, providing a valuable tool for epidemiology and mobile health.

  11. Development of a fluorescent antibody virus neutralisation test (FAVN test) for the quantitation of rabies-neutralising antibody.

    PubMed

    Cliquet, F; Aubert, M; Sagné, L

    1998-03-01

    A microtest named the FAVN test (fluorescent antibody virus neutralisation test), which is an adaptation of the original rapid fluorescent focus inhibition test (RFFIT) has been developed and evaluated. One hundred percent specificity was estimated using 414 sera from dogs sampled in rabies-free areas or from non-vaccinated animals. The accuracy as determined by the agreement between observed and expected values using sera of known titres was satisfactory. Serum samples from unvaccinated and vaccinated dogs (using sera with titres near 0.5 IU/ml) were assayed for rabies antibody by the FAVN test, the RFFIT and the mouse neutralisation test (MNT): comparative results obtained on the same sera with the three tests showed good agreement. Furthermore, distinguishing negative sera from positive sera with low titres is much easier with the FAVN test than with the RFFIT.

  12. How You Can Get the Best Results with Home Use Tests

    MedlinePlus

    ... Use Tests How You Can Get the Best Results With Home Use Tests Share Tweet Linkedin Pin ... follow all test instructions to get an accurate result. Most home tests require specific timing, materials, and ...

  13. A comparative study of qualitative and quantitative methods for the assessment of adhesive remnant after bracket debonding.

    PubMed

    Cehreli, S Burcak; Polat-Ozsoy, Omur; Sar, Cagla; Cubukcu, H Evren; Cehreli, Zafer C

    2012-04-01

    The amount of the residual adhesive after bracket debonding is frequently assessed in a qualitative manner, utilizing the adhesive remnant index (ARI). This study aimed to investigate whether quantitative assessment of the adhesive remnant yields more precise results compared to qualitative methods utilizing the 4- and 5-point ARI scales. Twenty debonded brackets were selected. Evaluation and scoring of the adhesive remnant on bracket bases were made consecutively using: 1. qualitative assessment (visual scoring) and 2. quantitative measurement (image analysis) on digital photographs. Image analysis was made on scanning electron micrographs (SEM) and high-precision elemental maps of the adhesive remnant as determined by energy dispersed X-ray spectrometry. Evaluations were made in accordance with the original 4-point and the modified 5-point ARI scales. Intra-class correlation coefficients (ICCs) were calculated, and the data were evaluated using Friedman test followed by Wilcoxon signed ranks test with Bonferroni correction. ICC statistics indicated high levels of agreement for qualitative visual scoring among examiners. The 4-point ARI scale was compliant with the SEM assessments but indicated significantly less adhesive remnant compared to the results of quantitative elemental mapping. When the 5-point scale was used, both quantitative techniques yielded similar results with those obtained qualitatively. These results indicate that qualitative visual scoring using the ARI is capable of generating similar results with those assessed by quantitative image analysis techniques. In particular, visual scoring with the 5-point ARI scale can yield similar results with both the SEM analysis and elemental mapping.

  14. Probing myocardium biomechanics using quantitative optical coherence elastography

    NASA Astrophysics Data System (ADS)

    Wang, Shang; Lopez, Andrew L.; Morikawa, Yuka; Tao, Ge; Li, Jiasong; Larina, Irina V.; Martin, James F.; Larin, Kirill V.

    2015-03-01

    We present a quantitative optical coherence elastographic method for noncontact assessment of the myocardium elasticity. The method is based on shear wave imaging optical coherence tomography (SWI-OCT), where a focused air-puff system is used to induce localized tissue deformation through a low-pressure short-duration air stream and a phase-sensitive OCT system is utilized to monitor the propagation of the induced tissue displacement with nanoscale sensitivity. The 1-D scanning of M-mode OCT imaging and the application of optical phase retrieval and mapping techniques enable the reconstruction and visualization of 2-D depth-resolved shear wave propagation in tissue with ultra-high frame rate. The feasibility of this method in quantitative elasticity measurement is demonstrated on tissue-mimicking phantoms with the estimated Young's modulus compared with uniaxial compression tests. We also performed pilot experiments on ex vivo mouse cardiac muscle tissues with normal and genetically altered cardiomyocytes. Our results indicate this noncontact quantitative optical coherence elastographic method can be a useful tool for the cardiac muscle research and studies.

  15. 40 CFR 89.509 - Calculation and reporting of test results.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... results. 89.509 Section 89.509 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Selective Enforcement Auditing § 89.509 Calculation and reporting of test results. (a) Initial test results... rounds these results, in accordance with ASTM E29-93a, to the number of decimal places contained in the...

  16. 40 CFR 89.509 - Calculation and reporting of test results.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... results. 89.509 Section 89.509 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Selective Enforcement Auditing § 89.509 Calculation and reporting of test results. (a) Initial test results... rounds these results, in accordance with ASTM E29-93a, to the number of decimal places contained in the...

  17. 40 CFR 89.509 - Calculation and reporting of test results.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... results. 89.509 Section 89.509 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Selective Enforcement Auditing § 89.509 Calculation and reporting of test results. (a) Initial test results... rounds these results, in accordance with ASTM E29-93a, to the number of decimal places contained in the...

  18. NEXT Ion Engine 2000 Hour Wear Test Results

    NASA Technical Reports Server (NTRS)

    Soulas, George C.; Kamhawi, Hani; Patterson, Michael J.; Britton, Melissa A.; Frandina, Michael M.

    2004-01-01

    The results of the NEXT 2000 h wear test are presented. This test was conducted with a 40 cm engineering model ion engine, designated EM1, at a 3.52 A beam current and 1800 V beam power supply voltage. Performance tests, which were conducted over a throttling range of 1.1 to 6.9 kW throughout the wear test, demonstrated that EM1 satisfied all thruster performance requirements. The ion engine accumulated 2038 h of operation at a thruster input power of 6.9 kW, processing 43 kg of xenon. Overall ion engine performance, which includes thrust, thruster input power, specific impulse, and thrust efficiency, was steady with no indications of performance degradation. The ion engine was also inspected following the test. This paper presents these findings.

  19. Overview of Classical Test Theory and Item Response Theory for Quantitative Assessment of Items in Developing Patient-Reported Outcome Measures

    PubMed Central

    Cappelleri, Joseph C.; Lundy, J. Jason; Hays, Ron D.

    2014-01-01

    Introduction The U.S. Food and Drug Administration’s patient-reported outcome (PRO) guidance document defines content validity as “the extent to which the instrument measures the concept of interest” (FDA, 2009, p. 12). “Construct validity is now generally viewed as a unifying form of validity for psychological measurements, subsuming both content and criterion validity” (Strauss & Smith, 2009, p. 7). Hence both qualitative and quantitative information are essential in evaluating the validity of measures. Methods We review classical test theory and item response theory approaches to evaluating PRO measures including frequency of responses to each category of the items in a multi-item scale, the distribution of scale scores, floor and ceiling effects, the relationship between item response options and the total score, and the extent to which hypothesized “difficulty” (severity) order of items is represented by observed responses. Conclusion Classical test theory and item response theory can be useful in providing a quantitative assessment of items and scales during the content validity phase of patient-reported outcome measures. Depending on the particular type of measure and the specific circumstances, either one or both approaches should be considered to help maximize the content validity of PRO measures. PMID:24811753

  20. MR morphology of triangular fibrocartilage complex: correlation with quantitative MR and biomechanical properties.

    PubMed

    Bae, Won C; Ruangchaijatuporn, Thumanoon; Chang, Eric Y; Biswas, Reni; Du, Jiang; Statum, Sheronda; Chung, Christine B

    2016-04-01

    To evaluate pathology of the triangular fibrocartilage complex (TFCC) using high-resolution morphologic magnetic resonance (MR) imaging, and compare with quantitative MR and biomechanical properties. Five cadaveric wrists (22-70 years) were imaged at 3 T using morphologic (proton density weighted spin echo, PD FS, and 3D spoiled gradient echo, 3D SPGR) and quantitative MR sequences to determine T2 and T1rho properties. In eight geographic regions, morphology of TFC disc and laminae were evaluated for pathology and quantitative MR values. Samples were disarticulated and biomechanical indentation testing was performed on the distal surface of the TFC disc. On morphologic PD SE images, TFC disc pathology included degeneration and tears, while that of the laminae included degeneration, degeneration with superimposed tear, mucinous transformation, and globular calcification. Punctate calcifications were highly visible on 3D SPGR images and found only in pathologic regions. Disc pathology occurred more frequently in proximal regions of the disc than distal regions. Quantitative MR values were lowest in normal samples, and generally higher in pathologic regions. Biomechanical testing demonstrated an inverse relationship, with indentation modulus being high in normal regions with low MR values. The laminae studied were mostly pathologic, and additional normal samples are needed to discern quantitative changes. These results show technical feasibility of morphologic MR, quantitative MR, and biomechanical techniques to characterize pathology of the TFCC. Quantitative MRI may be a suitable surrogate marker of soft tissue mechanical properties, and a useful adjunct to conventional morphologic MR techniques.

  1. Variation in Results Release and Patient Portal Access to Diagnostic Test Results at an Academic Medical Center

    PubMed Central

    Krasowski, Matthew D.; Grieme, Caleb V.; Cassady, Brian; Dreyer, Nicholas R.; Wanat, Karolyn A.; Hightower, Maia; Nepple, Kenneth G.

    2017-01-01

    Background: Electronic health records (EHRs) are commonplace in industrialized countries. Many hospitals are granting their patients access to their medical information through online patient portals. In this report, we describe a retrospective analysis of patient access to diagnostic test results released through the patient portal (MyChart; Epic, Inc.) at a state academic medical center. Methods: We analyzed 6 months of data for anatomic pathology, clinical laboratory, and radiology test results to evaluate variations in results release (automated vs. manual) and subsequent patient access to the institutional patient portal. During this period, diagnostic test results were released for all patient encounters including inpatient units, outpatient clinics, and the emergency department. Results: Manual results release by providers before automated release time occurred most commonly in the outpatient setting. The highest rates of access of diagnostic test results occurred for outpatients (about 30% overall view rate), females (two times or more compared to males in nearly every age bracket), and 20–45-year-old. Access rates of diagnostic tests in the emergency department or inpatient units were <10% across all populations. Access of diagnostic test results was very low for 12–17-year-old, likely influenced by institutional policies limiting parental proxy access within this pediatric age range. Approximately 20% of outpatient laboratory results were viewed by patients within 8 h of release from the EHR to the patient portal and 10% within 2 h of release. Conclusions: Patient accessing of diagnostic test results were generally higher for females, outpatients, and 20–45-year-old. Approximately, 20% of outpatient results were viewed quickly by patients after release to the EHR. PMID:29226008

  2. 40 CFR 90.709 - Calculation and reporting of test results.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... expressed to one additional significant figure. (b) Final test results are calculated by summing the initial... applicable standard expressed to one additional significant figure. (c) The final deteriorated test results...

  3. 40 CFR 90.709 - Calculation and reporting of test results.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... expressed to one additional significant figure. (b) Final test results are calculated by summing the initial... applicable standard expressed to one additional significant figure. (c) The final deteriorated test results...

  4. Quantitative Percussion Diagnostics For Evaluating Bond Integrity Between Composite Laminates

    NASA Astrophysics Data System (ADS)

    Poveromo, Scott Leonard

    Conventional nondestructive testing (NDT) techniques used to detect defects in composites are not able to determine intact bond integrity within a composite structure and are costly to use on large and complex shaped surfaces. To overcome current NDT limitations, a new technology was utilized based on quantitative percussion diagnostics (QPD) to better quantify bond quality in fiber reinforced composite materials. Experimental results indicate that this technology is capable of detecting 'kiss' bonds (very low adhesive shear strength), caused by the application of release agents on the bonding surfaces, between flat composite laminates bonded together with epoxy adhesive. Specifically, the local value of the loss coefficient determined from quantitative percussion testing was found to be significantly greater for a release coated panel compared to that for a well bonded sample. Also, the local value of the probe force or force returned to the probe after impact was observed to be lower for the release coated panels. The increase in loss coefficient and decrease in probe force are thought to be due to greater internal friction during the percussion event for poorly bonded specimens. NDT standards were also fabricated by varying the cure parameters of an epoxy film adhesive. Results from QPD for the variable cure NDT standards and lap shear strength measurements taken of mechanical test specimens were compared and analyzed. Finally, experimental results have been compared to a finite element analysis to understand the visco-elastic behavior of the laminates during percussion testing. This comparison shows how a lower quality bond leads to a reduction in the percussion force by biasing strain in the percussion tested side of the panel.

  5. Differential GPS/inertial navigation approach/landing flight test results

    NASA Technical Reports Server (NTRS)

    Snyder, Scott; Schipper, Brian; Vallot, Larry; Parker, Nigel; Spitzer, Cary

    1992-01-01

    In November of 1990 a joint Honeywell/NASA-Langley differential GPS/inertial flight test was conducted at Wallops Island, Virginia. The test objective was to acquire a system performance database and demonstrate automatic landing using an integrated differential GPS/INS (Global Positioning System/inertial navigation system) with barometric and radar altimeters. The flight test effort exceeded program objectives with over 120 landings, 36 of which were fully automatic differential GPS/inertial landings. Flight test results obtained from post-flight data analysis are discussed. These results include characteristics of differential GPS/inertial error, using the Wallops Island Laser Tracker as a reference. Data on the magnitude of the differential corrections and vertical channel performance with and without radar altimeter augmentation are provided.

  6. ADVANCING THE STUDY OF VIOLENCE AGAINST WOMEN USING MIXED METHODS: INTEGRATING QUALITATIVE METHODS INTO A QUANTITATIVE RESEARCH PROGRAM

    PubMed Central

    Testa, Maria; Livingston, Jennifer A.; VanZile-Tamsen, Carol

    2011-01-01

    A mixed methods approach, combining quantitative with qualitative data methods and analysis, offers a promising means of advancing the study of violence. Integrating semi-structured interviews and qualitative analysis into a quantitative program of research on women’s sexual victimization has resulted in valuable scientific insight and generation of novel hypotheses for testing. This mixed methods approach is described and recommendations for integrating qualitative data into quantitative research are provided. PMID:21307032

  7. Quantitative sensory testing and pain-evoked cytokine reactivity: comparison of patients with sickle cell disease to healthy matched controls.

    PubMed

    Campbell, Claudia M; Carroll, C Patrick; Kiley, Kasey; Han, Dingfen; Haywood, Carlton; Lanzkron, Sophie; Swedberg, Lauren; Edwards, Robert R; Page, Gayle G; Haythornthwaite, Jennifer A

    2016-04-01

    Sickle cell disease (SCD) is an inherited blood disorder associated with significant morbidity, which includes severe episodic pain, and, often, chronic pain. Compared to healthy individuals, patients with SCD report enhanced sensitivity to thermal detection and pain thresholds and have altered inflammatory profiles, yet no studies to date have examined biomarker reactivity after laboratory-induced pain. We sought to examine this relationship in patients with SCD compared to healthy control participants. We completed quantitative sensory testing in 83 patients with SCD and sequential blood sampling in 27 of them, whom we matched (sex, age, race, body mass index, and education) to 27 healthy controls. Surprisingly, few quantitative sensory testing differences emerged between groups. Heat pain tolerance, pressure pain threshold at the trapezius, thumb, and quadriceps, and thermal temporal summation at 45°C differed between groups in the expected direction, whereas conditioned pain modulation and pain ratings to hot water hand immersion were counterintuitive, possibly because of tailoring the water temperature to a perceptual level; patients with SCD received milder temperatures. In the matched subsample, group differences and group-by-time interactions were observed in biomarkers including tumor necrosis factor alpha, interleukin-1ß, interleukin-4, and neuropeptide Y. These findings highlight the utility of laboratory pain testing methods for understanding individual differences in inflammatory cytokines. Our findings suggest amplified pain-evoked proinflammatory cytokine reactivity among patients with SCD relative to carefully matched controls. Future research is warranted to evaluate the impact of enhanced pain-related cytokine response and whether it is predictive of clinical characteristics and the frequency/severity of pain crises in patients with SCD.

  8. Evaluation of LOINC for Representing Constitutional Cytogenetic Test Result Reports

    PubMed Central

    Heras, Yan Z.; Mitchell, Joyce A.; Williams, Marc S.; Brothman, Arthur R.; Huff, Stanley M.

    2009-01-01

    Genetic testing is becoming increasingly important to medical practice. Integrating genetics and genomics data into electronic medical records is crucial in translating genetic discoveries into improved patient care. Information technology, especially Clinical Decision Support Systems, holds great potential to help clinical professionals take full advantage of genomic advances in their daily medical practice. However, issues relating to standard terminology and information models for exchanging genetic testing results remain relatively unexplored. This study evaluates whether the current LOINC standard is adequate to represent constitutional cytogenetic test result reports using sample result reports from ARUP Laboratories. The results demonstrate that current standard terminology is insufficient to support the needs of coding cytogenetic test results. The terminology infrastructure must be developed before clinical information systems will be able to handle the high volumes of genetic data expected in the near future. PMID:20351857

  9. Evaluation of LOINC for representing constitutional cytogenetic test result reports.

    PubMed

    Heras, Yan Z; Mitchell, Joyce A; Williams, Marc S; Brothman, Arthur R; Huff, Stanley M

    2009-11-14

    Genetic testing is becoming increasingly important to medical practice. Integrating genetics and genomics data into electronic medical records is crucial in translating genetic discoveries into improved patient care. Information technology, especially Clinical Decision Support Systems, holds great potential to help clinical professionals take full advantage of genomic advances in their daily medical practice. However, issues relating to standard terminology and information models for exchanging genetic testing results remain relatively unexplored. This study evaluates whether the current LOINC standard is adequate to represent constitutional cytogenetic test result reports using sample result reports from ARUP Laboratories. The results demonstrate that current standard terminology is insufficient to support the needs of coding cytogenetic test results. The terminology infrastructure must be developed before clinical information systems will be able to handle the high volumes of genetic data expected in the near future.

  10. Aquifer test results, Green Swamp area, Florida

    USGS Publications Warehouse

    Tibbals, C.H.; Grubb, Hayes F.

    1982-01-01

    An aquifer test conducted in the Green Swamp area December 15-16 , 1975 was designed to stress the uppermost part of the Floridan aquifer so that the leakage characteristics of the overlying confining bed could be determined. A well tapping the upper part of the Floridan aquifer was pumped at a rate of about 1,040 gallons per minute for 35 hours; drawdown was measured in the Floridan aquifer and in two horizons in the confining bed. Analysis of the data indicates that the transmissivity of the uppper 160 feet of the Floridan is 13,000 square feet per day, the storage coefficient is about 0.0002.5, and the overlying confining bed leakance coefficient is about 0.02 to 0.025 per day. The vertical hydraulic diffusivity of the confining bed ranged from 610 square feet per day to 16,000 square feet per day. Results of the test indicate that, in the area of the test site, a Floridan aquifer well field would induce additional recharge to the Floridan. As a result of that increased recharge , water levels in the surficial aquifer would tend to stand lower, runoff from the area would tend to be less, and, perhaps, evapotranspiration would be less than normal.(USGS)

  11. Variation in Results Release and Patient Portal Access to Diagnostic Test Results at an Academic Medical Center.

    PubMed

    Krasowski, Matthew D; Grieme, Caleb V; Cassady, Brian; Dreyer, Nicholas R; Wanat, Karolyn A; Hightower, Maia; Nepple, Kenneth G

    2017-01-01

    Electronic health records (EHRs) are commonplace in industrialized countries. Many hospitals are granting their patients access to their medical information through online patient portals. In this report, we describe a retrospective analysis of patient access to diagnostic test results released through the patient portal (MyChart; Epic, Inc.) at a state academic medical center. We analyzed 6 months of data for anatomic pathology, clinical laboratory, and radiology test results to evaluate variations in results release (automated vs. manual) and subsequent patient access to the institutional patient portal. During this period, diagnostic test results were released for all patient encounters including inpatient units, outpatient clinics, and the emergency department. Manual results release by providers before automated release time occurred most commonly in the outpatient setting. The highest rates of access of diagnostic test results occurred for outpatients (about 30% overall view rate), females (two times or more compared to males in nearly every age bracket), and 20-45-year-old. Access rates of diagnostic tests in the emergency department or inpatient units were <10% across all populations. Access of diagnostic test results was very low for 12-17-year-old, likely influenced by institutional policies limiting parental proxy access within this pediatric age range. Approximately 20% of outpatient laboratory results were viewed by patients within 8 h of release from the EHR to the patient portal and 10% within 2 h of release. Patient accessing of diagnostic test results were generally higher for females, outpatients, and 20-45-year-old. Approximately, 20% of outpatient results were viewed quickly by patients after release to the EHR.

  12. A Comparison Between The NORCAT Rover Test Results and the ISRU Excavation System Model Predictions Results

    NASA Technical Reports Server (NTRS)

    Gallo, Christopher A.; Agui, Juan H.; Creager, Colin M.; Oravec, Heather A.

    2012-01-01

    An Excavation System Model has been written to simulate the collection and transportation of regolith on the moon. The calculations in this model include an estimation of the forces on the digging tool as a result of excavation into the regolith. Verification testing has been performed and the forces recorded from this testing were compared to the calculated theoretical data. The Northern Centre for Advanced Technology Inc. rovers were tested at the NASA Glenn Research Center Simulated Lunar Operations facility. This testing was in support of the In-Situ Resource Utilization program Innovative Partnership Program. Testing occurred in soils developed at the Glenn Research Center which are a mixture of different types of sands and whose soil properties have been well characterized. This testing is part of an ongoing correlation of actual field test data to the blade forces calculated by the Excavation System Model. The results from this series of tests compared reasonably with the predicted values from the code.

  13. Quantitative analysis of comparative genomic hybridization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Manoir, S. du; Bentz, M.; Joos, S.

    1995-01-01

    Comparative genomic hybridization (CGH) is a new molecular cytogenetic method for the detection of chromosomal imbalances. Following cohybridization of DNA prepared from a sample to be studied and control DNA to normal metaphase spreads, probes are detected via different fluorochromes. The ratio of the test and control fluorescence intensities along a chromosome reflects the relative copy number of segments of a chromosome in the test genome. Quantitative evaluation of CGH experiments is required for the determination of low copy changes, e.g., monosomy or trisomy, and for the definition of the breakpoints involved in unbalanced rearrangements. In this study, a programmore » for quantitation of CGH preparations is presented. This program is based on the extraction of the fluorescence ratio profile along each chromosome, followed by averaging of individual profiles from several metaphase spreads. Objective parameters critical for quantitative evaluations were tested, and the criteria for selection of suitable CGH preparations are described. The granularity of the chromosome painting and the regional inhomogeneity of fluorescence intensities in metaphase spreads proved to be crucial parameters. The coefficient of variation of the ratio value for chromosomes in balanced state (CVBS) provides a general quality criterion for CGH experiments. Different cutoff levels (thresholds) of average fluorescence ratio values were compared for their specificity and sensitivity with regard to the detection of chromosomal imbalances. 27 refs., 15 figs., 1 tab.« less

  14. Quantitative characterisation of sedimentary grains

    NASA Astrophysics Data System (ADS)

    Tunwal, Mohit; Mulchrone, Kieran F.; Meere, Patrick A.

    2016-04-01

    Analysis of sedimentary texture helps in determining the formation, transportation and deposition processes of sedimentary rocks. Grain size analysis is traditionally quantitative, whereas grain shape analysis is largely qualitative. A semi-automated approach to quantitatively analyse shape and size of sand sized sedimentary grains is presented. Grain boundaries are manually traced from thin section microphotographs in the case of lithified samples and are automatically identified in the case of loose sediments. Shape and size paramters can then be estimated using a software package written on the Mathematica platform. While automated methodology already exists for loose sediment analysis, the available techniques for the case of lithified samples are limited to cases of high definition thin section microphotographs showing clear contrast between framework grains and matrix. Along with the size of grain, shape parameters such as roundness, angularity, circularity, irregularity and fractal dimension are measured. A new grain shape parameter developed using Fourier descriptors has also been developed. To test this new approach theoretical examples were analysed and produce high quality results supporting the accuracy of the algorithm. Furthermore sandstone samples from known aeolian and fluvial environments from the Dingle Basin, County Kerry, Ireland were collected and analysed. Modern loose sediments from glacial till from County Cork, Ireland and aeolian sediments from Rajasthan, India have also been collected and analysed. A graphical summary of the data is presented and allows for quantitative distinction between samples extracted from different sedimentary environments.

  15. Virtex-II Pro SEE Test Methods and Results

    NASA Technical Reports Server (NTRS)

    Petrick, David; Powell, Wesley; Howard, James W., Jr.; LaBel, Kenneth A.

    2004-01-01

    The objective of this coarse Single Event Effect (SEE) test is to determine the suitability of the commercial Virtex-II Pro family for use in spaceflight applications. To this end, this test is primarily intended to determine any Singe Event Latchup (SEL) susceptibilities for these devices. Secondly, this test is intended to measure the level of Single Event Upset (SEU) susceptibilities and in a general sense where they occur. The coarse SEE test was performed on a commercial XC2VP7 device, a relatively small single processor version of the Virtex-II Pro. As the XC2VP7 shares the same functional block design and fabrication process with the larger Virtex-II Pro devices, the results of this test should also be applicable to the larger devices. The XC2VP7 device was tested on a commercial Virtex-II Pro development board. The testing was performed at the Cyclotron laboratories at Texas A&M and Michigan State Universities using ions of varying energy levels and fluences.

  16. Comparison of estrogen receptor results from pathology reports with results from central laboratory testing.

    PubMed

    Collins, Laura C; Marotti, Jonathan D; Baer, Heather J; Tamimi, Rulla M

    2008-02-06

    We compared estrogen receptor (ER) assay results abstracted from pathology reports with ER results determined on the same specimens by a central laboratory with an immunohistochemical assay. Paraffin sections were cut from tissue microarrays containing 3093 breast cancer specimens from women enrolled in the Nurses' Health Study, 1851 of which had both pathology reports and tissue available for central laboratory testing. All sections were immunostained for ER at the same time. The original assays were biochemical for 1512 (81.7%) of the 1851 specimens, immunohistochemical for 336 (18.2%), and immunofluorescent for three (0.2%). ER results from pathology reports and repeat central laboratory testing were in agreement for 87.3% of specimens (1615 of the 1851 specimens; kappa statistic = 0.64, P < .001). When the comparison was restricted to the specimens for which the ER assays were originally performed by immunohistochemistry, the agreement rate increased to 92.3% of specimens (310 of the 336 specimens; kappa statistic = 0.78, P < .001). Thus, ER assay results from pathology reports appear to be a reasonable alternative to central laboratory ER testing for large, population-based studies of patients with breast cancer.

  17. Effect of Box-Cox transformation on power of Haseman-Elston and maximum-likelihood variance components tests to detect quantitative trait Loci.

    PubMed

    Etzel, C J; Shete, S; Beasley, T M; Fernandez, J R; Allison, D B; Amos, C I

    2003-01-01

    Non-normality of the phenotypic distribution can affect power to detect quantitative trait loci in sib pair studies. Previously, we observed that Winsorizing the sib pair phenotypes increased the power of quantitative trait locus (QTL) detection for both Haseman-Elston (HE) least-squares tests [Hum Hered 2002;53:59-67] and maximum likelihood-based variance components (MLVC) analysis [Behav Genet (in press)]. Winsorizing the phenotypes led to a slight increase in type 1 error in H-E tests and a slight decrease in type I error for MLVC analysis. Herein, we considered transforming the sib pair phenotypes using the Box-Cox family of transformations. Data were simulated for normal and non-normal (skewed and kurtic) distributions. Phenotypic values were replaced by Box-Cox transformed values. Twenty thousand replications were performed for three H-E tests of linkage and the likelihood ratio test (LRT), the Wald test and other robust versions based on the MLVC method. We calculated the relative nominal inflation rate as the ratio of observed empirical type 1 error divided by the set alpha level (5, 1 and 0.1% alpha levels). MLVC tests applied to non-normal data had inflated type I errors (rate ratio greater than 1.0), which were controlled best by Box-Cox transformation and to a lesser degree by Winsorizing. For example, for non-transformed, skewed phenotypes (derived from a chi2 distribution with 2 degrees of freedom), the rates of empirical type 1 error with respect to set alpha level=0.01 were 0.80, 4.35 and 7.33 for the original H-E test, LRT and Wald test, respectively. For the same alpha level=0.01, these rates were 1.12, 3.095 and 4.088 after Winsorizing and 0.723, 1.195 and 1.905 after Box-Cox transformation. Winsorizing reduced inflated error rates for the leptokurtic distribution (derived from a Laplace distribution with mean 0 and variance 8). Further, power (adjusted for empirical type 1 error) at the 0.01 alpha level ranged from 4.7 to 17.3% across all tests

  18. Deimos Methane-Oxygen Rocket Engine Test Results

    NASA Astrophysics Data System (ADS)

    Engelen, S.; Souverein, L. J.; Twigt, D. J.

    This paper presents the results of the first DEIMOS Liquid Methane/Oxygen rocket engine test campaign. DEIMOS is an acronym for `Delft Experimental Methane Oxygen propulsion System'. It is a project performed by students under the auspices of DARE (Delft Aerospace Rocket Engineering). The engine provides a theoretical design thrust of 1800 N and specific impulse of 287 s at a chamber pressure of 40 bar with a total mass flow of 637 g/s. It has links to sustainable development, as the propellants used are one of the most promising so-called `green propellants'-combinations, currently under scrutiny by the industry, and the engine is designed to be reusable. This paper reports results from the provisional tests, which had the aim of verifying the engine's ability to fire, and confirming some of the design assumptions to give confidence for further engine designs. Measurements before and after the tests are used to determine first estimates on feed pressures, propellant mass flows and achieved thrust. These results were rather disappointing from a performance point of view, with an average thrust of a mere 3.8% of the design thrust, but nonetheless were very helpful. The reliability of ignition and stability of combustion are discussed as well. An initial assessment as to the reusability, the flexibility and the adaptability of the engine was made. The data provides insight into (methane/oxygen) engine designs, leading to new ideas for a subsequent design. The ultimate goal of this project is to have an operational rocket and to attempt to set an amateur altitude record.

  19. Advanced Guidance and Control Methods for Reusable Launch Vehicles: Test Results

    NASA Technical Reports Server (NTRS)

    Hanson, John M.; Jones, Robert E.; Krupp, Don R.; Fogle, Frank R. (Technical Monitor)

    2002-01-01

    There are a number of approaches to advanced guidance and control (AG&C) that have the potential for achieving the goals of significantly increasing reusable launch vehicle (RLV) safety/reliability and reducing the cost. In this paper, we examine some of these methods and compare the results. We briefly introduce the various methods under test, list the test cases used to demonstrate that the desired results are achieved, show an automated test scoring method that greatly reduces the evaluation effort required, and display results of the tests. Results are shown for the algorithms that have entered testing so far.

  20. MCM - 2 and Ki - 67 as proliferation markers in renal cell carcinoma: A quantitative and semi - quantitative analysis.

    PubMed

    Mehdi, Muhammad Zain; Nagi, Abdul Hanan; Naseem, Nadia

    2016-01-01

    Fuhrman nuclear grade is the most important histological parameter to predict prognosis in a patient of renal cell carcinoma (RCC). However, it suffers from inter-observer and intra-observer variation giving rise to need of a parameter that not only correlates with nuclear grade but is also objective and reproducible. Proliferation is the measure of aggressiveness of a tumour and it is strongly correlated with Fuhrman nuclear grade, clinical survival and recurrence in RCC. Ki-67 is conventionally used to assess proliferation. Mini-chromosome maintenance 2 (MCM-2) is a lesser known marker of proliferation and identifies a greater proliferation faction. This study was designed to assess the prognostic significance of MCM-2 by comparing it with Fuhrman nuclear grade and Ki-67. n=50 cases of various ages, stages, histological subtypes and grades of RCC were selected for this study. Immunohistochemical staining using Ki-67(MIB-1, Mouse monoclonal antibody, Dako) and MCM-2 (Mouse monoclonal antibody, Thermo) was performed on the paraffin embedded blocks in the department of Morbid anatomy and Histopathology, University of Health Sciences, Lahore. Labeling indices (LI) were determined by two pathologists independently using quantitative and semi-quantitative analysis. Statistical analysis was carried out using SPSS 20.0. Kruskall-Wallis test was used to determine a correlation of proliferation markers with grade, and Pearson's correlate was used to determine correlation between the two proliferation markers. Labeling index of MCM-2 (median=24.29%) was found to be much higher than Ki-67(median=13.05%). Both markers were significantly related with grade (p=0.00; Kruskall-Wallis test). LI of MCM-2 was found to correlate significantly with LI of Ki-67(r=0.0934;p=0.01 with Pearson's correlate). Results of semi-quantitative analysis correlated well with quantitative analysis. Both Ki-67 and MCM-2 are markers of proliferation which are closely linked to grade. Therefore, they