Sample records for quantity personal dose

  1. Test of ring, eye lens and whole body dosemeters for the dose quantity Hp(3) to be used in interventional radiology

    NASA Astrophysics Data System (ADS)

    Szumska, A.; Budzanowski, M.; Kopeć, R.

    2017-11-01

    In its statement on tissue reactions approved on 21st April 2011, the International Commission on Radiological Protection (ICRP, 2012) reviewed its recommendation concerning the equivalent dose limit for the eye lens and reduced the dose limits for occupationally exposed persons to 20 mSv in a year, averaged over defined periods of 5 years, with no single year exceeding 50 mSv. This limit was approved and written down in the new EURATOM (European Atomic Energy Community) directive 2013/59 and in the IAEA (International Atomic Energy Agency) BSS (Basic Safety Standard) of July 2014. For that reason, the necessity to monitor the eye lens may become more important than it was before. However, specially dedicated dosemeters for the dose quantity Hp(3) are using very rarely. Commonly use are only whole body personal dosemeters for the personal dose equivalent quantities Hp(10) worn on the trunk and ring dosemeters worn on finger to measure the quantity Hp(0.07). Therefore, in this work it was investigated whether dosemeters from routine use calibrated in terms of Hp(10) and Hp(0.07) and worn on thyroid collar and protective apron could deliver similar results like dedicated eye lens dosemeter worn close to the eyes. The results show that the best method if dedicated eye lens dosimeters is not used is to measure doses in terms of Hp(0.07) on the thyroid collar (Pearson product, r=0.85). Obtained results shows also importance of proper localization of eye lens dosimeter (close to the eye, from side of the X-ray source).

  2. Personal Dose Equivalent Conversion Coefficients For Photons To 1 GEV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veinot, K. G.; Hertel, N. E.

    2010-09-27

    The personal dose equivalent, H{sub p}(d), is the quantity recommended by the International Commission on Radiation Units and Measurements (ICRU) to be used as an approximation of the protection quantity Effective Dose when performing personal dosemeter calibrations. The personal dose equivalent can be defined for any location and depth within the body. Typically, the location of interest is the trunk where personal dosemeters are usually worn and in this instance a suitable approximation is a 30 cm X 30 cm X 15 cm slab-type phantom. For this condition the personal dose equivalent is denoted as H{sub p,slab}(d) and the depths,more » d, are taken to be 0.007 cm for non-penetrating and 1 cm for penetrating radiation. In operational radiation protection a third depth, 0.3 cm, is used to approximate the dose to the lens of the eye. A number of conversion coefficients for photons are available for incident energies up to several MeV, however, data to higher energies are limited. In this work conversion coefficients up to 1 GeV have been calculated for H{sub p,slab}(10) and H{sub p,slab}(3) using both the kerma approximation and by tracking secondary charged particles. For H{sub p}(0.07) the conversion coefficients were calculated, but only to 10 MeV due to computational limitations. Additionally, conversions from air kerma to H{sub p,slab}(d) have been determined and are reported. The conversion coefficients were determined for discrete incident energies, but analytical fits of the coefficients over the energy range are provided. Since the inclusion of air can influence the production of secondary charged particles incident on the face of the phantom conversion coefficients have been determined both in vacuo and with the source and slab immersed within a sphere in air. The conversion coefficients for the personal dose equivalent are compared to the appropriate protection quantity, calculated according to the recommendations of the latest International Commission on Radiological Protection (ICRP) guidance.« less

  3. [Dosimetric system for assessing doses received by people occupationally exposed to external sources of ionizing radiation].

    PubMed

    Brodecki, Marcin; Domienik, Joanna U; Zmyślony, Marek

    2012-01-01

    The current system of dosimetric quantities has been defined by the International Commission on Radiological Protection (ICRP) and the International Commission on Radiation Units and Measurements (ICRU). Complexity of the system implies the physical nature of ionizing radiation, resulting from the presence of different types of radiation of different ionization capabilities, as well as the individual radiation sensitivity of biological material exposed. According to the latest recommendations, there are three types of dosimeter quantities relevant to radiation protection and radiological assessment of occupational exposure. These are the basic quantities, safety quantities and operational quantities. Dose limits for occupational exposure relate directly to the protection quantities, i.e. the equivalent dose and effective dose, while these quantities are practically unmeasurable in real measurement conditions. For this reason, in the system of dosimetric quantities directly measurable operating volumes were defined. They represent equivalents of the protection quantities that allow for a reliable assessment of equivalent and effective dose by conducting routine monitoring of occupational exposure. This paper presents the characteristics of these quantities, their relationships and importance in assessing individual effects of radiation. Also the methods for their implementation in personal and environmental dosimetry were showcased. The material contained in the article is a compendium of essential information about dosimetric quantities with reference to the contemporary requirements of the law, including the changed annual occupational exposure limit for the lens of the eye. The material is especially addressed to those responsible for dosimetry monitoring in the workplace, radiation protection inspectors and occupational health physicians.

  4. General requirements to implement the personal dose equivalent Hp(10) in Brazil

    NASA Astrophysics Data System (ADS)

    Gomes Lopes, Amanda; Da Silva, Francisco Cesar Augusto

    2018-03-01

    To update the dosimetry quantity with the international community, Brazil is changing the Individual Dose (Hx) to the Personal Dose Equivalent Hp(10). A bibliographical survey on the technical and administrative requirements of nine countries that use Hp(10) was carried out to obtain the most relevant ones. All of them follow IEC and ISO guidelines for technical requirements, but administrative requirements change from country to country. Based on countries experiences, this paper presents a list of important general requirements to implement Hp(10) and to prepare the Brazilian requirements according to the international scientific community.

  5. Monitoring the eye lens: which dose quantity is adequate?

    NASA Astrophysics Data System (ADS)

    Behrens, R.; Dietze, G.

    2010-07-01

    Recent epidemiological studies suggest a rather low dose threshold (below 0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimized and current dose limits for the eye lens may be reduced in the future. The question of which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens arises from this situation. While in many countries dosemeters calibrated in terms of the dose equivalent quantity Hp(0.07) have been seen as being adequate for monitoring the dose to the eye lens, this might be questionable in the case of reduced dose limits and, thus, it may become necessary to use the dose equivalent quantity Hp(3) for this purpose. To discuss this question, the dose conversion coefficients for the equivalent dose of the eye lens (in the following eye lens dose) were determined for realistic photon and beta radiation fields and compared with the values of the corresponding conversion coefficients for the different operational quantities. The values obtained lead to the following conclusions: in radiation fields where most of the dose comes from photons, especially x-rays, it is appropriate to use dosemeters calibrated in terms of Hp(0.07) on a slab phantom, while in other radiation fields (dominated by beta radiation or unknown contributions of photon and beta radiation) dosemeters calibrated in terms of Hp(3) on a slab phantom should be used. As an alternative, dosemeters calibrated in terms of Hp(0.07) on a slab phantom could also be used; however, in radiation fields containing beta radiation with the end point energy near 1 MeV, an overestimation of the eye lens dose by up to a factor of 550 is possible.

  6. Monitoring the eye lens: which dose quantity is adequate?

    PubMed

    Behrens, R; Dietze, G

    2010-07-21

    Recent epidemiological studies suggest a rather low dose threshold (below 0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimized and current dose limits for the eye lens may be reduced in the future. The question of which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens arises from this situation. While in many countries dosemeters calibrated in terms of the dose equivalent quantity H(p)(0.07) have been seen as being adequate for monitoring the dose to the eye lens, this might be questionable in the case of reduced dose limits and, thus, it may become necessary to use the dose equivalent quantity H(p)(3) for this purpose. To discuss this question, the dose conversion coefficients for the equivalent dose of the eye lens (in the following eye lens dose) were determined for realistic photon and beta radiation fields and compared with the values of the corresponding conversion coefficients for the different operational quantities. The values obtained lead to the following conclusions: in radiation fields where most of the dose comes from photons, especially x-rays, it is appropriate to use dosemeters calibrated in terms of H(p)(0.07) on a slab phantom, while in other radiation fields (dominated by beta radiation or unknown contributions of photon and beta radiation) dosemeters calibrated in terms of H(p)(3) on a slab phantom should be used. As an alternative, dosemeters calibrated in terms of H(p)(0.07) on a slab phantom could also be used; however, in radiation fields containing beta radiation with the end point energy near 1 MeV, an overestimation of the eye lens dose by up to a factor of 550 is possible.

  7. Weighting factors for radiation quality: how to unite the two current concepts.

    PubMed

    Kellerer, Albrecht M

    2004-01-01

    The quality factor, Q(L), used to be the universal weighting factor to account for radiation quality, until--in its 1991 Recommendations--the ICRP established a dichotomy between 'computable' and 'measurable' quantities. The new concept of the radiation weighting factor, w(R), was introduced for use with the 'computable' quantities, such as the effective dose, E. At the same time, the application of Q(L) was restricted to 'measurable' quantities, such as the operational quantities ambient dose equivalent or personal dose equivalent. The result has been a dual system of incoherent dosimetric quantities. The most conspicuous inconsistency resulted for neutrons, for which the new concept of wR had been primarily designed. While its definition requires an accounting for the gamma rays produced by neutron capture in the human body, this effect is not adequately reflected in the numerical values of wR, which are now suitable for mice, but are--at energies of the incident neutrons below 1 MeV--conspicuously too large for man. A recent Report 92 to ICRP has developed a proposal to correct the current imbalance and to define a linkage between the concepts Q(L) and wR. The proposal is here considered within a broader assessment of the rationale that led to the current dual system of dosimetric quantities.

  8. SU-E-I-57: Estimating the Occupational Eye Lens Dose in Interventional Radiology Using Active Personal Dosimeters Worn On the Chest

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Omar, A; Marteinsdottir, M; Kadesjo, N

    Purpose: To provide a general formalism for determination of occupational eye lens dose based on the response of an active personal dosimeter (APD) worn at chest level above the radiation protection apron. Methods: The formalism consists of three factors: (1) APD conversion factor converting the reading at chest level (APDchest) to the corresponding personal dose equivalent at eye level, (2) Dose conversion factor transferring the measured dose quantity, Hp(10), into a dose quantity relevant for the eye lens dose, (3) Correction factor accounting for differences in exposure of the eye(s) compared to the exposure at chest level (e.g., due tomore » protective lead glasses).The different factors were investigated and evaluated based on phantom and clinical measurements performed in an x-ray angiography suite for interventional cardiology. Results: The eye lens dose can be conservatively estimated by assigning an appropriate numerical value to each factor entering the formalism that in most circumstances overestimates the dose. Doing so, the eye lens dose to the primary operator and assisting staff was estimated in this work as D-eye,primary = 2.0 APDchest and D-eye,assisting = 1.0 APDchest, respectively.The annual eye lens dose to three nurses and one cardiologist was estimated to be 2, 2, 2, and 13 mSv (Hp(0.07)), respectively, using a TLD dosimeter worn at eye level. In comparison, using the formalism and APDchest measurements, the respective doses were 2, 2, 2, and 16 mSv (Hp(3)). Conclusion: The formalism outlined in this work can be used to estimate the occupational eye lens dose from the response of an APD worn on the chest. The formalism is general and could be applied also to other types of dosimeters. However, the numerical value of the different factors may differ from those obtained with the APD’s used in this work due to differences in dosimeter properties.« less

  9. Dose conversion coefficients for electron exposure of the human eye lens

    NASA Astrophysics Data System (ADS)

    Behrens, R.; Dietze, G.; Zankl, M.

    2009-07-01

    Recent epidemiological studies suggest a rather low dose threshold (below 0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimized and current dose limits for the eye lens may be reduced in the future. Two questions arise from this situation: first, which dose quantity is related to the risk of developing a cataract, and second, which personal dose equivalent quantity is appropriate for monitoring this dose quantity. While the dose equivalent quantity Hp(0.07) has often been seen as being sufficiently accurate for monitoring the dose to the lens of the eye, this would be questionable in the case when the dose limits were reduced and, thus, it may be necessary to generally use the dose equivalent quantity Hp(3) for this purpose. The basis for a decision, however, must be the knowledge of accurate conversion coefficients from fluence to equivalent dose to the lens. This is especially important for low-penetrating radiation, for example, electrons. Formerly published values of conversion coefficients are based on quite simple models of the eye. In this paper, quite a sophisticated model of the eye including the inner structure of the lens was used for the calculations and precise conversion coefficients for electrons with energies between 0.2 MeV and 12 MeV, and for angles of radiation incidence between 0° and 45° are presented. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are up to 1000 times smaller for electron energies below 1 MeV, nearly equal at 1 MeV and above 4 MeV, and by a factor of 1.5 larger at about 1.5 MeV electron energy.

  10. Dose conversion coefficients for electron exposure of the human eye lens.

    PubMed

    Behrens, R; Dietze, G; Zankl, M

    2009-07-07

    Recent epidemiological studies suggest a rather low dose threshold (below 0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimized and current dose limits for the eye lens may be reduced in the future. Two questions arise from this situation: first, which dose quantity is related to the risk of developing a cataract, and second, which personal dose equivalent quantity is appropriate for monitoring this dose quantity. While the dose equivalent quantity H(p)(0.07) has often been seen as being sufficiently accurate for monitoring the dose to the lens of the eye, this would be questionable in the case when the dose limits were reduced and, thus, it may be necessary to generally use the dose equivalent quantity H(p)(3) for this purpose. The basis for a decision, however, must be the knowledge of accurate conversion coefficients from fluence to equivalent dose to the lens. This is especially important for low-penetrating radiation, for example, electrons. Formerly published values of conversion coefficients are based on quite simple models of the eye. In this paper, quite a sophisticated model of the eye including the inner structure of the lens was used for the calculations and precise conversion coefficients for electrons with energies between 0.2 MeV and 12 MeV, and for angles of radiation incidence between 0 degrees and 45 degrees are presented. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are up to 1000 times smaller for electron energies below 1 MeV, nearly equal at 1 MeV and above 4 MeV, and by a factor of 1.5 larger at about 1.5 MeV electron energy.

  11. Calibration of an eye lens dosemeter in terms of Hp(3) to be used in interventional radiology

    NASA Astrophysics Data System (ADS)

    Borges, F. L. S.; Guimarães, M. C.; Da Silva, T. A.; Nogueira Tavares, M. S.

    2014-11-01

    Recently, the International Commission on Radiological Protection has reviewed epidemiological evidences suggesting that there were tissue reaction effects in the eye lens below the previously considered absorbed dose threshold. A new statement related to the eye lens was issued that changed the absorbed dose threshold and reduced the dose limits for occupationally exposed persons. As consequence, some planned exposures require eye lens dosimetry and a debate was raised on the adequacy of the dosimetric quantity and on its method of measurement. The aim of this work was to study the methodology for calibrating the EYE-DTM holder with a TLD-100H Harshaw chip detector and to determine its angular and energy dependences in terms of personal dose equivalent, Hp(3).

  12. Phantom-derived estimation of effective dose equivalent from X rays with and without a lead apron.

    PubMed

    Mateya, C F; Claycamp, H G

    1997-06-01

    Organ dose equivalents were measured in a humanoid phantom in order to estimate effective dose equivalent (H(E)) and effective dose (E) from low-energy x rays and in the presence or absence of a protective lead apron. Plane-parallel irradiation conditions were approximated using direct x-ray beams of 76 and 104 kVp and resulting dosimetry data was adjusted to model exposures conditions in fluoroscopy settings. Values of H(E) and E estimated under-shielded conditions were compared to the results of several recent studies that used combinations of measured and calculated dosimetry to model exposures to radiologists. While the estimates of H(E) and E without the lead apron were within 0.2 to 20% of expected values, estimates based on personal monitors worn at the (phantom) waist (underneath the apron) underestimated either H(E) or E while monitors placed at the neck (above the apron) significantly overestimated both quantities. Also, the experimentally determined H(E) and E were 1.4 to 3.3 times greater than might be estimated using recently reported "two-monitor" algorithms for the estimation of effective dose quantities. The results suggest that accurate estimation of either H(E) or E from personal monitors under conditions of partial body exposures remains problematic and is likely to require the use of multiple monitors.

  13. PNNL Measurement Results for the 2016 Criticality Accident Dosimetry Exercise at the Nevada National Security Stite (IER-148)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rathbone, Bruce A.; Morley, Shannon M.; Stephens, John A.

    The Pacific Northwest National Laboratory (PNNL) participated in a criticality accident dosimetry intercomparison exercise held at the Nevada National Security Site (NNSS) May 24-27, 2016. The exercise was administered by Lawrence Livermore National Laboratory (LLNL) and consisted of three exposures performed using the Godiva-IV critical assembly housed in the Device Assembly Facility (DAF) located on the NNSS site. The exercise allowed participants to test the ability of their nuclear accident dosimeters to meet the performance criteria in ANSI/HPS N13.3-2013, Dosimetry for Criticality Accidents and to obtain new measurement data for use in revising dose calculation methods and quick sort screeningmore » methods where appropriate. PNNL participated with new prototype Personal Nuclear Accident Dosimeter (PNAD) and Fixed Nuclear Accident Dosimeter (FNAD) designs as well as the existing historical PNAD design. The new prototype designs incorporate optically stimulated luminescence (OSL) dosimeters in place of thermoluminescence dosimeters (TLDs), among other design changes, while retaining the same set of activation foils historically used. The default dose calculation methodology established decades ago for use with activation foils in PNNL PNADs and FNADs was used to calculate neutron dose results for both the existing and prototype dosimeters tested in the exercise. The results indicate that the effective cross sections and/or dose conversion factors used historically need to be updated to accurately measure the operational quantities recommended for nuclear accident dosimetry in ANSI/HPS N13.3-2013 and to ensure PNAD and FNAD performance meets the ANSI/HPS N13.3-2013 performance criteria. The operational quantities recommended for nuclear accident dosimetry are personal absorbed dose, Dp(10), and ambient absorbed dose, D*(10).« less

  14. Paving the way to personalized medicine: production of some theragnostic radionuclides at Brookhaven National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Srivastava S. C.

    2011-06-06

    This paper introduces a relatively novel paradigm that involves specific individual radionuclides or radionuclide pairs that have emissions that allow pre-therapy low-dose imaging plus higher-dose therapy in the same patient. We have made an attempt to sort out and organize a number of such theragnostic radionuclides and radionuclide pairs that may potentially bring us closer to the age-long dream of personalized medicine for performing tailored low-dose molecular imaging (SPECT/CT or PET/CT) to provide the necessary pre-therapy information on biodistribution, dosimetry, the limiting or critical organ or tissue, and the maximum tolerated dose (MTD), etc. If the imaging results then warrantmore » it, it would be possible to perform higher-dose targeted molecular therapy in the same patient with the same radiopharmaceutical. A major problem that remains yet to be fully resolved is the lack of availability, in sufficient quantities, of a majority of the best candidate theragnostic radionuclides in a no-carrier-added (NCA) form. A brief description of the recently developed new or modified methods at BNL for the production of four theragnostic radionuclides, whose nuclear, physical, and chemical characteristics seem to show great promise for personalized cancer therapy are described.« less

  15. Quantities for assessing high photon doses to the body: a calculational approach.

    PubMed

    Eakins, Jonathan S; Ainsbury, Elizabeth A

    2018-06-01

    Tissue reactions are the most clinically significant consequences of high-dose exposures to ionising radiation. However, currently there is no universally recognized dose quantity that can be used to assess and report generalised risks to individuals following whole body exposures in the high-dose range. In this work, a number of potential dose quantities are presented and discussed, with mathematical modelling techniques employed to compare them and explore when their differences are most or least manifest. The results are interpreted to propose the average (D GRB ) of the absorbed doses to the stomach, small intestine, red bone marrow, and brain as the optimum quantity for informing assessments of risk. A second, maximally conservative dose quantity (D Max ) is also suggested, which places limits on any under-estimates resulting from the adoption of D GRB . The primary aim of this work is to spark debate, with further work required to refine the final choice of quantity or quantities most appropriate for the full range of different potential exposure scenarios.

  16. Air kerma to Hp(3) conversion coefficients for a new cylinder phantom for photon reference radiation qualities.

    PubMed

    Behrens, R

    2012-09-01

    The International Organization for Standardization (ISO) has issued a standard series on photon reference radiation qualities (ISO 4037). In this series, no conversion coefficients are contained for the quantity personal dose equivalent at a 3 mm depth, H(p)(3). In the past, for this quantity, a slab phantom was recommended as a calibration phantom; however, a cylinder phantom much better approximates the shape of a human head than a slab phantom. Therefore, in this work, the conversion coefficients from air kerma to H(p)(3) for the cylinder phantom are supplied for X- and gamma radiation qualities defined in ISO 4037.

  17. Appropriate Use of Effective Dose in Radiation Protection and Risk Assessment.

    PubMed

    Fisher, Darrell R; Fahey, Frederic H

    2017-08-01

    Effective dose was introduced by the ICRP for the single, over-arching purpose of setting limits for radiation protection. Effective dose is a derived quantity or mathematical construct and not a physical, measurable quantity. The formula for calculating effective dose to a reference model incorporates terms to account for all radiation types, organ and tissue radiosensitivities, population groups, and multiple biological endpoints. The properties and appropriate applications of effective dose are not well understood by many within and outside the health physics profession; no other quantity in radiation protection has been more confusing or misunderstood. According to ICRP Publication 103, effective dose is to be used for "prospective dose assessment for planning and optimization in radiological protection, and retrospective demonstration of compliance for regulatory purposes." In practice, effective dose has been applied incorrectly to predict cancer risk among exposed persons. The concept of effective dose applies generally to reference models only and not to individual subjects. While conceived to represent a measure of cancer risk or heritable detrimental effects, effective dose is not predictive of future cancer risk. The formula for calculating effective dose incorporates committee-selected weighting factors for radiation quality and organ sensitivity; however, the organ weighting factors are averaged across all ages and both genders and thus do not apply to any specific individual or radiosensitive subpopulations such as children and young women. Further, it is not appropriate to apply effective dose to individual medical patients because patient-specific parameters may vary substantially from the assumptions used in generalized models. Also, effective dose is not applicable to therapeutic uses of radiation, as its mathematical underpinnings pertain only to observed late (stochastic) effects of radiation exposure and do not account for short-term adverse tissue reactions. The weighting factors incorporate substantial uncertainties, and linearity of the dose-response function at low dose is uncertain and highly disputed. Since effective dose is not predictive of future cancer incidence, it follows that effective dose should never be used to estimate future cancer risk from specific sources of radiation exposure. Instead, individual assessments of potential detriment should only be based on organ or tissue radiation absorbed dose, together with best scientific understanding of the corresponding dose-response relationships.

  18. Reliability of eye lens dosimetry in workers of a positron emission tomography radiopharmaceutical production facility.

    PubMed

    da Silva, Teógenes A; Guimarães, Margarete C; Meireles, Leonardo S; Teles, Luciana L D; Lacerda, Marco Aurélio S

    2016-11-01

    A new regulatory statement was issued concerning the eye lens radiation protection of persons in planned exposures. A debate was raised on the adequacy of the dosimetric quantity and on its method of measurement. The aim of this work was to establish the individual monitoring procedure with the EYE-D™ holder and a MCP-N LiF:Mg,Cu,P thermoluminescent chip detector for measuring the personal dose equivalent H p (3) in workers of a Positron Emission Tomography Radiopharmaceutical Production Facility. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Dose conversion coefficients for photon exposure of the human eye lens.

    PubMed

    Behrens, R; Dietze, G

    2011-01-21

    In recent years, several papers dealing with the eye lens dose have been published, because epidemiological studies implied that the induction of cataracts occurs even at eye lens doses of less than 500 mGy. Different questions were addressed: Which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens? Is a new definition of the dose quantity H(p)(3) based on a cylinder phantom to represent the human head necessary? Are current conversion coefficients from fluence to equivalent dose to the lens sufficiently accurate? To investigate the latter question, a realistic model of the eye including the inner structure of the lens was developed. Using this eye model, conversion coefficients for electrons have already been presented. In this paper, the same eye model-with the addition of the whole body-was used to calculate conversion coefficients from fluence (and air kerma) to equivalent dose to the lens for photon radiation from 5 keV to 10 MeV. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are similar between 40 keV and 1 MeV and lower by up to a factor of 5 and 7 for photon energies at about 10 keV and 10 MeV, respectively. Above 1 MeV, the new values (calculated without kerma approximation) should be applied in pure photon radiation fields, while the values adopted by the ICRP in 1996 (calculated with kerma approximation) should be applied in case a significant contribution from secondary electrons originating outside the body is present.

  20. Dose conversion coefficients for photon exposure of the human eye lens

    NASA Astrophysics Data System (ADS)

    Behrens, R.; Dietze, G.

    2011-01-01

    In recent years, several papers dealing with the eye lens dose have been published, because epidemiological studies implied that the induction of cataracts occurs even at eye lens doses of less than 500 mGy. Different questions were addressed: Which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens? Is a new definition of the dose quantity Hp(3) based on a cylinder phantom to represent the human head necessary? Are current conversion coefficients from fluence to equivalent dose to the lens sufficiently accurate? To investigate the latter question, a realistic model of the eye including the inner structure of the lens was developed. Using this eye model, conversion coefficients for electrons have already been presented. In this paper, the same eye model—with the addition of the whole body—was used to calculate conversion coefficients from fluence (and air kerma) to equivalent dose to the lens for photon radiation from 5 keV to 10 MeV. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are similar between 40 keV and 1 MeV and lower by up to a factor of 5 and 7 for photon energies at about 10 keV and 10 MeV, respectively. Above 1 MeV, the new values (calculated without kerma approximation) should be applied in pure photon radiation fields, while the values adopted by the ICRP in 1996 (calculated with kerma approximation) should be applied in case a significant contribution from secondary electrons originating outside the body is present.

  1. Analysis of localised dose distribution in human body by Monte Carlo code system for photon irradiation.

    PubMed

    Ohnishi, S; Odano, N; Nariyama, N; Saito, K

    2004-01-01

    In usual personal dosimetry, whole body irradiation is assumed. However, the opportunity of partial irradiation is increasing and the tendencies of protection quantities caused under those irradiation conditions are different. The code system has been developed and effective dose and organ absorbed doses have been calculated in the case of horizontal narrow photon beam irradiated from various directions at three representative body sections, 40, 50 and 60 cm originating from the top of the head. This work covers 24 beam directions, each 15 degrees angle ranging from 0 degrees to 345 degrees, three energy levels, 45 keV, 90 keV and 1.25 MeV, and three beam diameters of 1, 2 and 4 cm. These results show that the beam injected from diagonally front or other specific direction causes peak dose in the case of partial irradiation.

  2. Effect of the Scattering Radiation in Air and Two Type of Slap Phantom between PMMA and the ISO Water Phantom for Personal Dosimeters Calibration

    NASA Astrophysics Data System (ADS)

    Kamwang, N.; Rungseesumran, T.; Saengchantr, D.; Monthonwattana, S.; Pungkun, V.

    2017-06-01

    The calibration of personal dosimeter to determine the quantities of the personal dose equivalent, Hp(d), is required to be placed on a suitable phantom in order to provide a reasonable approximation to the radiation backscattering properties as equivalent as part of body. The dosimeter which is worn on the trunk usually calibrated with slap phantom which recommended in ICRU 47 with dimension of 30 cm (w) x 30 cm (h) x 15 cm (t) PMMA slab phantom to achieve uniformity in calibration procedures, on the other hand the International Organization for Standardization (ISO), ISO 4037-3, proposed the ISO water slap phantom, with PMMA walls, same dimension but different wall thickness (front wall 2.5 mm and other side wall 10 mm thick) and fill with water. However, some laboratories are still calibrating a personal dosimeter in air in term of ambient dose equivalent, H*(d). This research study the effect of the scattering radiation in two type of those slap phantoms and in air, to calibrate two type of OSL (XA and LA) and electronic personal dosimeters. The X-ray and Cs-137 radiation field with the energy range from 33 to 662 keV were used. The results of this study will be discussed.

  3. Measurement of dose distribution in the spherical phantom onboard the ISS-KIBO module -MATROSHKA-R in KIBO-

    NASA Astrophysics Data System (ADS)

    Kodaira, Satoshi; Kawashima, Hajime; Kurano, Mieko; Uchihori, Yukio; Nikolaev, Igor; Ambrozova, Iva; Kitamura, Hisashi; Kartsev, Ivan; Tolochek, Raisa; Shurshakov, Vyacheslav

    The measurement of dose equivalent and effective dose during manned space missions on the International Space Station (ISS) is important for evaluating the risk to astronaut health and safety when exposed to space radiation. The dosimetric quantities are constantly changing and strongly depend on the level of solar activity and the various spacecraft- and orbit-dependent parameters such as the shielding distribution in the ISS module, location of the spacecraft within its orbit relative to the Earth, the attitude (orientation) and altitude. Consequently, the continuous monitoring of dosimetric quantities is required to record and evaluate the personal radiation dose for crew members during spaceflight. The dose distributions in the phantom body and on its surface give crucial information to estimate the dose equivalent in the human body and effective dose in manned space mission. We have measured the absorbed dose and dose equivalent rates using passive dosimeters installed in the spherical phantom in Japanese Experiment Module (“KIBO”) of the ISS in the framework of Matroshka-R space experiment. The exposure duration was 114 days from May 21 to September 12, 2012. The phantom consists of tissue-equivalent material covered with a poncho jacket with 32 pockets on its surface and 20 container rods inside of the phantom. The phantom diameter is 35 cm and the mass is 32 kg. The passive dosimeters consisted of a combination of luminescent detectors of Al _{2}O _{3};C OSL and CaSO _{4}:Dy TLD and CR-39 plastic nuclear track detectors. As one of preliminary results, the dose distribution on the phantom surface measured with OSL detectors installed in the jacket pockets is found to be ranging from 340 muGy/day to 260 muGy/day. In this talk, we will present the detail dose distributions, and variations of LET spectra and quality factor obtained outside and inside of the spherical phantom installed in the ISS-KIBO.

  4. Monte Carlo simulation of the operational quantities at the realistic mixed neutron-photon radiation fields CANEL and SIGMA.

    PubMed

    Lacoste, V; Gressier, V

    2007-01-01

    The Institute for Radiological Protection and Nuclear Safety owns two facilities producing realistic mixed neutron-photon radiation fields, CANEL, an accelerator driven moderator modular device, and SIGMA, a graphite moderated americium-beryllium assembly. These fields are representative of some of those encountered at nuclear workplaces, and the corresponding facilities are designed and used for calibration of various instruments, such as survey meters, personal dosimeters or spectrometric devices. In the framework of the European project EVIDOS, irradiations of personal dosimeters were performed at CANEL and SIGMA. Monte Carlo calculations were performed to estimate the reference values of the personal dose equivalent at both facilities. The Hp(10) values were calculated for three different angular positions, 0 degrees, 45 degrees and 75 degrees, of an ICRU phantom located at the position of irradiation.

  5. NUNDO: a numerical model of a human torso phantom and its application to effective dose equivalent calculations for astronauts at the ISS.

    PubMed

    Puchalska, Monika; Bilski, Pawel; Berger, Thomas; Hajek, Michael; Horwacik, Tomasz; Körner, Christine; Olko, Pawel; Shurshakov, Vyacheslav; Reitz, Günther

    2014-11-01

    The health effects of cosmic radiation on astronauts need to be precisely quantified and controlled. This task is important not only in perspective of the increasing human presence at the International Space Station (ISS), but also for the preparation of safe human missions beyond low earth orbit. From a radiation protection point of view, the baseline quantity for radiation risk assessment in space is the effective dose equivalent. The present work reports the first successful attempt of the experimental determination of the effective dose equivalent in space, both for extra-vehicular activity (EVA) and intra-vehicular activity (IVA). This was achieved using the anthropomorphic torso phantom RANDO(®) equipped with more than 6,000 passive thermoluminescent detectors and plastic nuclear track detectors, which have been exposed to cosmic radiation inside the European Space Agency MATROSHKA facility both outside and inside the ISS. In order to calculate the effective dose equivalent, a numerical model of the RANDO(®) phantom, based on computer tomography scans of the actual phantom, was developed. It was found that the effective dose equivalent rate during an EVA approaches 700 μSv/d, while during an IVA about 20 % lower values were observed. It is shown that the individual dose based on a personal dosimeter reading for an astronaut during IVA results in an overestimate of the effective dose equivalent of about 15 %, whereas under an EVA conditions the overestimate is more than 200 %. A personal dosemeter can therefore deliver quite good exposure records during IVA, but may overestimate the effective dose equivalent received during an EVA considerably.

  6. 77 FR 14199 - Revision of Regulations Implementing the Convention on International Trade in Endangered Species...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-08

    ... quantity of beluga sturgeon caviar (250 grams) that qualifies as a personal or household effect. When the special rule was written, 250 grams was the quantity of sturgeon caviar that CITES Parties had agreed... reduced the quantity of sturgeon caviar that qualifies as a personal or household effect from 250 grams to...

  7. An analysis of the equivalent dose calculation for the remainder tissues

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zankl, M.; Drexler, G.

    1995-09-01

    In the 1990 Recommendations of the International Commission on Radiological Protection, the risk-weighted quantity {open_quotes}effective dose equivalent{close_quotes} was replaced by a similar quantity, {open_quotes}effective dose.{close_quotes} Among other alterations, the selection of the organs and tissues contributing to the risk-weighted quantity and their respective weighting factors were changed, including a modified definition of the so-called {open_quotes}remainder.{close_quotes} Close consideration of this latter definition shows that is causes certain ambiguities are unexpected effects which are dealt with in the following. For several geometries of external photon irradiation, the numerical differences of two possible methods of evaluating the remainder dose from the doses tomore » ten single organs, namely as arithmetic mean or as mass weighted average, are assessed. It is shown that deviation from these averaging procedures, as prescribed for these cases where a remainder organ receives a higher dose than an organ with a specified weighting factor, cause discontinuities in the energy dependence of the remainder dose and, consequently, also non-additivity of this quantity. These problems are discussed, and it is shown that, although the numerical consequences for the calculation of the effective dose are small, this unsatisfactory situation needs clarification. One approach might be to abolish some of the ICRP guidance relating to the appropriate tissue weighting factors for the remainder tissues and organs and to make other guidance more precise. 14 refs., 12 figs., 2 tabs.« less

  8. Internal thyroid doses to Fukushima residents—estimation and issues remaining

    PubMed Central

    Kim, Eunjoo; Kurihara, Osamu; Kunishima, Naoaki; Momose, Takumaro; Ishikawa, Tetsuo; Akashi, Makoto

    2016-01-01

    Enormous quantities of radionuclides were released into the environment following the disastrous accident at the Fukushima Daiichi Nuclear Power Plant (FDNPP) in March 2011. It is of great importance to determine the exposure doses received by the populations living in the radiologically affected areas; however, there has been significant difficulty in estimating the internal thyroid dose received through the intake of short-lived radionuclides (mainly, 131I), because of the lack of early measurements on people. An estimation by the National Institute of Radiological Sciences for 1 April 2012 to 31 March 2013 was thus performed using a combination of the following three sources: thyroid measurement data (131I) for 1080 children examined in the screening campaign, whole-body counter measurement data (134Cs, 137Cs) for 3000 adults, and atmospheric transport dispersion model simulations. In this study, the residents of Futaba town, Iitate village and Iwaki city were shown to have the highest thyroid equivalent dose, and their doses were estimated to be mostly below 30 mSv. However, this result involved a lot of uncertainties and provided only representative values for the residents. The present paper outlines a more recent dose estimation and preliminary analyses of personal behavior data used in the new method. PMID:27538842

  9. Determination of dosimetric quantities in pediatric abdominal computed tomography scans*

    PubMed Central

    Jornada, Tiago da Silva; da Silva, Teógenes Augusto

    2014-01-01

    Objective Aiming at contributing to the knowledge on doses in computed tomography (CT), this study has the objective of determining dosimetric quantities associated with pediatric abdominal CT scans, comparing the data with diagnostic reference levels (DRL). Materials and methods The study was developed with a Toshiba Asteion single-slice CT scanner and a GE BrightSpeed multi-slice CT unit in two hospitals. Measurements were performed with a pencil-type ionization chamber and a 16 cm-diameter polymethylmethacrylate trunk phantom. Results No significant difference was observed in the values for weighted air kerma index (CW), but the differences were relevant in values for volumetric air kerma index (CVOL), air kerma-length product (PKL,CT) and effective dose. Conclusion Only the CW values were lower than the DRL, suggesting that dose optimization might not be necessary. However, PKL,CT and effective dose values stressed that there still is room for reducing pediatric radiation doses. The present study emphasizes the importance of determining all dosimetric quantities associated with CT scans. PMID:25741103

  10. AIR KERMA TO Hp(3) CONVERSION COEFFICIENTS FOR IEC 61267 RQR X-RAY RADIATION QUALITIES: APPLICATION TO DOSE MONITORING OF THE LENS OF THE EYE IN MEDICAL DIAGNOSTICS.

    PubMed

    Principi, S; Guardiola, C; Duch, M A; Ginjaume, M

    2016-09-01

    Recent studies highlight the fact that the new eye lens dose limit can be exceeded in interventional radiology procedures and that eye lens monitoring could be required for these workers. The recommended operational quantity for monitoring of eye lens exposure is the personal dose equivalent at 3 mm depth Hp(3) (ICRU 51). However, there are no available conversion coefficients in international standards, while in the literature coefficients have only been calculated for monoenergetic beams and for ISO 4037-1 X-ray qualities. The aim of this article is to provide air kerma to Hp(3) conversion coefficients for a cylindrical phantom made of ICRU-4 elements tissue-equivalent material for RQR radiation qualities (IEC-61267) from 40 to 120 kV and for angles of incidence from 0 to 180°, which are characteristic of medical workplace. Analytic calculations using interpolation techniques and Monte Carlo modelling have been compared. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Calculation of Radiation Protection Quantities and Analysis of Astronaut Orientation Dependence

    NASA Technical Reports Server (NTRS)

    Clowdsley, Martha S.; Nealy, John E.; Atwell, William; Anderson, Brooke M.; Luetke, Nathan J.; Wilson, John W.

    2006-01-01

    Health risk to astronauts due to exposure to ionizing radiation is a primary concern for exploration missions and may become the limiting factor for long duration missions. Methodologies for evaluating this risk in terms of radiation protection quantities such as dose, dose equivalent, gray equivalent, and effective dose are described. Environment models (galactic cosmic ray and solar particle event), vehicle/habitat geometry models, human geometry models, and transport codes are discussed and sample calculations for possible lunar and Mars missions are used as demonstrations. The dependence of astronaut health risk, in terms of dosimetric quantities, on astronaut orientation within a habitat is also examined. Previous work using a space station type module exposed to a proton spectrum modeling the October 1989 solar particle event showed that reorienting the astronaut within the module could change the calculated dose equivalent by a factor of two or more. Here the dose equivalent to various body tissues and the whole body effective dose due to both galactic cosmic rays and a solar particle event are calculated for a male astronaut in two different orientations, vertical and horizontal, in a representative lunar habitat. These calculations also show that the dose equivalent at some body locations resulting from a solar particle event can vary by a factor of two or more, but that the dose equivalent due to galactic cosmic rays has a much smaller (<15%) dependence on astronaut orientation.

  12. Information quantity and quality affect the realistic accuracy of personality judgment.

    PubMed

    Letzring, Tera D; Wells, Shannon M; Funder, David C

    2006-07-01

    Triads of unacquainted college students interacted in 1 of 5 experimental conditions that manipulated information quantity (amount of information) and information quality (relevance of information to personality), and they then made judgments of each others' personalities. To determine accuracy, the authors compared the ratings of each judge to a broad-based accuracy criterion composed of personality ratings from 3 types of knowledgeable informants (the self, real-life acquaintances, and clinician-interviewers). Results supported the hypothesis that information quantity and quality would be positively related to objective knowledge about the targets and realistic accuracy. Interjudge consensus and self-other agreement followed a similar pattern. These findings are consistent with expectations based on models of the process of accurate judgment (D. C. Funder, 1995, 1999) and consensus (D. A. Kenny, 1994). Copyright 2006 APA, all rights reserved.

  13. Application of a prospective model for calculating worker exposure due to the air pathway for operations in a laboratory.

    PubMed

    Grimbergen, T W M; Wiegman, M M

    2007-01-01

    In order to arrive at recommendations for guidelines on maximum allowable quantities of radioactive material in laboratories, a proposed mathematical model was used for the calculation of transfer fractions for the air pathway. A set of incident scenarios was defined, including spilling, leakage and failure of the fume hood. For these 'common incidents', dose constraints of 1 mSv and 0.1 mSv are proposed in case the operations are being performed in a controlled area and supervised area, respectively. In addition, a dose constraint of 1 microSv is proposed for each operation under regular working conditions. Combining these dose constraints and the transfer fractions calculated with the proposed model, maximum allowable quantities were calculated for different laboratory operations and situations. Provided that the calculated transfer fractions can be experimentally validated and the dose constraints are acceptable, it can be concluded from the results that the dose constraint for incidents is the most restrictive one. For non-volatile materials this approach leads to quantities much larger than commonly accepted. In those cases, the results of the calculations in this study suggest that limitation of the quantity of radioactive material, which can be handled safely, should be based on other considerations than the inhalation risks. Examples of such considerations might be the level of external exposure, uncontrolled spread of radioactive material by surface contamination, emissions in the environment and severe accidents like fire.

  14. Personalized Feedback on Staff Dose in Fluoroscopy-Guided Interventions: A New Era in Radiation Dose Monitoring.

    PubMed

    Sailer, Anna M; Vergoossen, Laura; Paulis, Leonie; van Zwam, Willem H; Das, Marco; Wildberger, Joachim E; Jeukens, Cécile R L P N

    2017-11-01

    Radiation safety and protection are a key component of fluoroscopy-guided interventions. We hypothesize that providing weekly personal dose feedback will increase radiation awareness and ultimately will lead to optimized behavior. Therefore, we designed and implemented a personalized feedback of procedure and personal doses for medical staff involved in fluoroscopy-guided interventions. Medical staff (physicians and technicians, n = 27) involved in fluoroscopy-guided interventions were equipped with electronic personal dose meters (PDMs). Procedure dose data including the dose area product and effective doses from PDMs were prospectively monitored for each consecutive procedure over an 8-month period (n = 1082). A personalized feedback form was designed displaying for each staff individually the personal dose per procedure, as well as relative and cumulative doses. This study consisted of two phases: (1) 1-5th months: Staff did not receive feedback (n = 701) and (2) 6-8th months: Staff received weekly individual dose feedback (n = 381). An anonymous evaluation was performed on the feedback and occupational dose. Personalized feedback was scored valuable by 76% of the staff and increased radiation dose awareness for 71%. 57 and 52% reported an increased feeling of occupational safety and changing their behavior because of personalized feedback, respectively. For technicians, the normalized dose was significantly lower in the feedback phase compared to the prefeedback phase: [median (IQR) normalized dose (phase 1) 0.12 (0.04-0.50) µSv/Gy cm 2 versus (phase 2) 0.08 (0.02-0.24) µSv/Gy cm 2 , p = 0.002]. Personalized dose feedback increases radiation awareness and safety and can be provided to staff involved in fluoroscopy-guided interventions.

  15. Internal thyroid doses to Fukushima residents-estimation and issues remaining.

    PubMed

    Kim, Eunjoo; Kurihara, Osamu; Kunishima, Naoaki; Momose, Takumaro; Ishikawa, Tetsuo; Akashi, Makoto

    2016-08-01

    Enormous quantities of radionuclides were released into the environment following the disastrous accident at the Fukushima Daiichi Nuclear Power Plant (FDNPP) in March 2011. It is of great importance to determine the exposure doses received by the populations living in the radiologically affected areas; however, there has been significant difficulty in estimating the internal thyroid dose received through the intake of short-lived radionuclides (mainly, (131)I), because of the lack of early measurements on people. An estimation by the National Institute of Radiological Sciences for 1 April 2012 to 31 March 2013 was thus performed using a combination of the following three sources: thyroid measurement data ((131)I) for 1080 children examined in the screening campaign, whole-body counter measurement data ((134)Cs, (137)Cs) for 3000 adults, and atmospheric transport dispersion model simulations. In this study, the residents of Futaba town, Iitate village and Iwaki city were shown to have the highest thyroid equivalent dose, and their doses were estimated to be mostly below 30 mSv. However, this result involved a lot of uncertainties and provided only representative values for the residents. The present paper outlines a more recent dose estimation and preliminary analyses of personal behavior data used in the new method. © The Author 2016. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  16. INTERCOMPARISON ON THE MEASUREMENT OF THE QUANTITY PERSONAL DOSE EQUIVALENT HP(10) IN PHOTON FIELDS. LINEARITY DEPENDENCE, LOWER LIMIT OF DETECTION AND UNCERTAINTY IN MEASUREMENT OF DOSIMETRY SYSTEMS OF INDIVIDUAL MONITORING SERVICES IN GABON AND GHANA.

    PubMed

    Ondo Meye, P; Schandorf, C; Amoako, J K; Manteaw, P O; Amoatey, E A; Adjei, D N

    2017-12-01

    An inter-comparison study was conducted to assess the capability of dosimetry systems of individual monitoring services (IMSs) in Gabon and Ghana to measure personal dose equivalent Hp(10) in photon fields. The performance indicators assessed were the lower limit of detection, linearity and uncertainty in measurement. Monthly and quarterly recording levels were proposed with corresponding values of 0.08 and 0.025 mSv, and 0.05 and 0.15 mSv for the TLD and OSL systems, respectively. The linearity dependence of the dosimetry systems was performed following the requirement given in the Standard IEC 62387 of the International Electrotechnical Commission (IEC). The results obtained for the two systems were satisfactory. The procedure followed for the uncertainty assessment is the one given in the IEC technical report TR62461. The maximum relative overall uncertainties, in absolute value, expressed in terms of Hp(10), for the TL dosimetry system Harshaw 6600, are 44. 35% for true doses below 0.40 mSv and 36.33% for true doses ≥0.40 mSv. For the OSL dosimetry system microStar, the maximum relative overall uncertainties, in absolute value, are 52.17% for true doses below 0.40 mSv and 37.43% for true doses ≥0.40 mSv. These results are in good agreement with the requirements for accuracy of the International Commission on Radiological protection. When expressing the uncertainties in terms of response, comparison with the IAEA requirements for overall accuracy showed that the uncertainty results were also acceptable. The values of Hp(10) directly measured by the two dosimetry systems showed a significant underestimation for the Harshaw 6600 system, and a slight overestimation for the microStar system. After correction for linearity of the measured doses, the two dosimetry systems gave better and comparable results. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. MIRD Pamphlet No. 21: A Generalized Schema for Radiopharmaceutical Dosimetry-Standardization of Nomenclature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bolch, W E; Eckerman, Keith F; Sgouros, George

    2009-03-01

    The internal dosimetry schema of the Medical Internal Radiation Dose (MIRD) Committee of the Society of Nuclear Medicine has provided a broad framework for assessment of the absorbed dose to whole organs, tissue subregions, voxelized tissue structures, and individual cellular compartments for use in both diagnostic and therapeutic nuclear medicine. The schema was originally published in 1968, revised in 1976, and republished in didactic form with comprehensive examples as the MIRD primer in 1988 and 1991. The International Commission on Radiological Protection (ICRP) is an organization that also supplies dosimetric models and technical data, for use in providing recommendations formore » limits on ionizing radiation exposure to workers and members of the general public. The ICRP has developed a dosimetry schema similar to that of the MIRD Committee but has used different terminology and symbols for fundamental quantities such as the absorbed fraction, specific absorbed fraction, and various dose coefficients. The MIRD Committee objectives for this pamphlet are 3-fold: to restate its schema for assessment of absorbed dose in a manner consistent with the needs of both the nuclear medicine and the radiation protection communities, with the goal of standardizing nomenclature; to formally adopt the dosimetry quantities equivalent dose and effective dose for use in comparative evaluations of potential risks of radiation-induced stochastic effects to patients after nuclear medicine procedures; and to discuss the need to identify dosimetry quantities based on absorbed dose that address deterministic effects relevant to targeted radionuclide therapy.« less

  18. Site-Specific Reference Person Parameters and Derived Concentration Standards for the Savannah River Site

    DOE PAGES

    Stone, Daniel K.; Higley, Kathryn A.; Jannik, G. Timothy

    2014-05-01

    The U.S. Department of Energy Order 458.1 states that the compliance with the 1 mSv annual dose constraint to a member of the public may be demonstrated by calculating dose to the maximally exposed individual (MEI) or to a representative person. Historically, the MEI concept was used for dose compliance at the Savannah River Site (SRS) using adult dose coefficients and adult male usage parameters. For future compliance, SRS plans to use the representative person concept for dose estimates to members of the public. The representative person dose will be based on the reference person dose coefficients from the U.S.more » DOE Derived Concentration Technical Standard and on usage parameters specific to SRS for the reference and typical person. Usage parameters and dose coefficients were determined for inhalation, ingestion and external exposure pathways. The parameters for the representative person were used to calculate and tabulate SRS-specific derived concentration standards (DCSs) for the pathways not included in DOE-STD-1196-2011.« less

  19. Agent based simulation on the process of human flesh search-From perspective of knowledge and emotion

    NASA Astrophysics Data System (ADS)

    Zhu, Hou; Hu, Bin

    2017-03-01

    Human flesh search as a new net crowed behavior, on the one hand can help us to find some special information, on the other hand may lead to privacy leaking and offending human right. In order to study the mechanism of human flesh search, this paper proposes a simulation model based on agent-based model and complex networks. The computational experiments show some useful results. Discovered information quantity and involved personal ratio are highly correlated, and most of net citizens will take part in the human flesh search or will not take part in the human flesh search. Knowledge quantity does not influence involved personal ratio, but influences whether HFS can find out the target human. When the knowledge concentrates on hub nodes, the discovered information quantity is either perfect or almost zero. Emotion of net citizens influences both discovered information quantity and involved personal ratio. Concretely, when net citizens are calm to face the search topic, it will be hardly to find out the target; But when net citizens are agitated, the target will be found out easily.

  20. 10 CFR 40.13 - Unimportant quantities of source material.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Unimportant quantities of source material. 40.13 Section 40.13 Energy NUCLEAR REGULATORY COMMISSION DOMESTIC LICENSING OF SOURCE MATERIAL Exemptions § 40.13 Unimportant quantities of source material. (a) Any person is exempt from the regulations in this part and from...

  1. ANALYSIS OF UNCERTAINTIES IN DOSE RECONSTRUCTION FROM BIOMARKERS: IMPACT ON STUDY DESIGN

    EPA Science Inventory

    The absorbed dose is defined as the quantity which has passed through the barriers (skin, GI tract, The absorbed dose of a pesticide can be estimated from its established urinary biomarker. ungs). For an exposure study, there are several options for biomarker collection, each w...

  2. Intercomparison of Monte Carlo radiation transport codes to model TEPC response in low-energy neutron and gamma-ray fields.

    PubMed

    Ali, F; Waker, A J; Waller, E J

    2014-10-01

    Tissue-equivalent proportional counters (TEPC) can potentially be used as a portable and personal dosemeter in mixed neutron and gamma-ray fields, but what hinders this use is their typically large physical size. To formulate compact TEPC designs, the use of a Monte Carlo transport code is necessary to predict the performance of compact designs in these fields. To perform this modelling, three candidate codes were assessed: MCNPX 2.7.E, FLUKA 2011.2 and PHITS 2.24. In each code, benchmark simulations were performed involving the irradiation of a 5-in. TEPC with monoenergetic neutron fields and a 4-in. wall-less TEPC with monoenergetic gamma-ray fields. The frequency and dose mean lineal energies and dose distributions calculated from each code were compared with experimentally determined data. For the neutron benchmark simulations, PHITS produces data closest to the experimental values and for the gamma-ray benchmark simulations, FLUKA yields data closest to the experimentally determined quantities. © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. What reaches the antenna? How to calibrate odor flux and ligand-receptor affinities.

    PubMed

    Andersson, Martin N; Schlyter, Fredrik; Hill, Sharon Rose; Dekker, Teun

    2012-06-01

    Physiological studies on olfaction frequently ignore the airborne quantities of stimuli reaching the sensory organ. We used a gas chromatography-calibrated photoionization detector to estimate quantities released from standard Pasteur pipette stimulus cartridges during repeated puffing of 27 compounds and verified how lack of quantification could obscure olfactory sensory neuron (OSN) affinities. Chemical structure of the stimulus, solvent, dose, storage condition, puff interval, and puff number all influenced airborne quantities. A model including boiling point and lipophilicity, but excluding vapor pressure, predicted airborne quantities from stimuli in paraffin oil on filter paper. We recorded OSN responses of Drosophila melanogaster, Ips typographus, and Culex quinquefasciatus, to known quantities of airborne stimuli. These demonstrate that inferred OSN tuning width, ligand affinity, and classification can be confounded and require stimulus quantification. Additionally, proper dose-response analysis shows that Drosophila AB3A OSNs are not promiscuous, but highly specific for ethyl hexanoate, with other earlier proposed ligands 10- to 10 000-fold less potent. Finally, we reanalyzed published Drosophila OSN data (DoOR) and demonstrate substantial shifts in affinities after compensation for quantity and puff number. We conclude that consistent experimental protocols are necessary for correct OSN classification and present some simple rules that make calibration, even retroactively, readily possible.

  4. Impact of the Revised 10 CFR 835 on the Neutron Dose Rates at LLNL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radev, R

    2009-01-13

    In June 2007, 10 CFR 835 [1] was revised to include new radiation weighting factors for neutrons, updated dosimetric models, and dose terms consistent with the newer ICRP recommendations. A significant aspect of the revised 10 CFR 835 is the adoption of the recommendations outlined in ICRP-60 [2]. The recommended new quantities demand a review of much of the basic data used in protection against exposure to sources of ionizing radiation. The International Commission on Radiation Units and Measurements has defined a number of quantities for use in personnel and area monitoring [3,4,5] including the ambient dose equivalent H*(d) tomore » be used for area monitoring and instrument calibrations. These quantities are used in ICRP-60 and ICRP-74. This report deals only with the changes in the ambient dose equivalent and ambient dose rate equivalent for neutrons as a result of the implementation of the revised 10 CFR 835. In the report, the terms neutron dose and neutron dose rate will be used for convenience for ambient neutron dose and ambient neutron dose rate unless otherwise stated. This report provides a qualitative and quantitative estimate of how much the neutron dose rates at LLNL will change with the implementation of the revised 10 CFR 835. Neutron spectra and dose rates from selected locations at the LLNL were measured with a high resolution spectroscopic neutron dose rate system (ROSPEC) as well as with a standard neutron rem meter (a.k.a., a remball). The spectra obtained at these locations compare well with the spectra from the Radiation Calibration Laboratory's (RCL) bare californium source that is currently used to calibrate neutron dose rate instruments. The measurements obtained from the high resolution neutron spectrometer and dose meter ROSPEC and the NRD dose meter compare within the range of {+-}25%. When the new radiation weighting factors are adopted with the implementation of the revised 10 CFR 835, the measured dose rates will increase by up to 22%. The health physicists should consider this increase for any areas that have dose rates near a posting limit, such as near the 100 mrem/hr for a high radiation area, as this increase in measured dose rate may result in some changes to postings and consequent radiological controls.« less

  5. Food consumption as affect modulation in borderline personality.

    PubMed

    Ambwani, Suman; Morey, Leslie C

    2015-04-01

    The present study examined relationships among negative affect, borderline personality features, and eating behavior through the experimental manipulation of mood. Undergraduate women (N = 307) completed a baseline mood assessment, viewed a 39-minute sad film either with or without concurrent food presentation, then completed a second mood assessment and questionnaires assessing personality and eating attitudes/behaviors. Women reporting more borderline personality features exhibited greater negative affect across time and were more reactive to the sad film. Food presentation appeared to have a small ameliorative effect on sadness and general negative affect. However, quantity of food consumption was associated with improvements in mood only for women reporting higher levels of borderline personality features. These data suggest that women with borderline personality characteristics may be at elevated risk for developing problems with binge eating, because consuming larger quantities of food appeared to have a tempering effect on their negative mood and feelings of sadness.

  6. 36 CFR 223.279 - Personal use.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... DISPOSAL OF NATIONAL FOREST SYSTEM TIMBER, SPECIAL FOREST PRODUCTS, AND FOREST BOTANICAL PRODUCTS Forest Botanical Products § 223.279 Personal use. (a) Personal use. A person may harvest forest botanical products... specific forest botanical products, which shall be equal to the amount or quantity authorized for free use...

  7. 36 CFR 223.279 - Personal use.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... DISPOSAL OF NATIONAL FOREST SYSTEM TIMBER, SPECIAL FOREST PRODUCTS, AND FOREST BOTANICAL PRODUCTS Forest Botanical Products § 223.279 Personal use. (a) Personal use. A person may harvest forest botanical products... specific forest botanical products, which shall be equal to the amount or quantity authorized for free use...

  8. 36 CFR 223.279 - Personal use.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... DISPOSAL OF NATIONAL FOREST SYSTEM TIMBER, SPECIAL FOREST PRODUCTS, AND FOREST BOTANICAL PRODUCTS Forest Botanical Products § 223.279 Personal use. (a) Personal use. A person may harvest forest botanical products... specific forest botanical products, which shall be equal to the amount or quantity authorized for free use...

  9. 36 CFR 223.279 - Personal use.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... DISPOSAL OF NATIONAL FOREST SYSTEM TIMBER, SPECIAL FOREST PRODUCTS, AND FOREST BOTANICAL PRODUCTS Forest Botanical Products § 223.279 Personal use. (a) Personal use. A person may harvest forest botanical products... specific forest botanical products, which shall be equal to the amount or quantity authorized for free use...

  10. A comparative study of space radiation organ doses and associated cancer risks using PHITS and HZETRN.

    PubMed

    Bahadori, Amir A; Sato, Tatsuhiko; Slaba, Tony C; Shavers, Mark R; Semones, Edward J; Van Baalen, Mary; Bolch, Wesley E

    2013-10-21

    NASA currently uses one-dimensional deterministic transport to generate values of the organ dose equivalent needed to calculate stochastic radiation risk following crew space exposures. In this study, organ absorbed doses and dose equivalents are calculated for 50th percentile male and female astronaut phantoms using both the NASA High Charge and Energy Transport Code to perform one-dimensional deterministic transport and the Particle and Heavy Ion Transport Code System to perform three-dimensional Monte Carlo transport. Two measures of radiation risk, effective dose and risk of exposure-induced death (REID) are calculated using the organ dose equivalents resulting from the two methods of radiation transport. For the space radiation environments and simplified shielding configurations considered, small differences (<8%) in the effective dose and REID are found. However, for the galactic cosmic ray (GCR) boundary condition, compensating errors are observed, indicating that comparisons between the integral measurements of complex radiation environments and code calculations can be misleading. Code-to-code benchmarks allow for the comparison of differential quantities, such as secondary particle differential fluence, to provide insight into differences observed in integral quantities for particular components of the GCR spectrum.

  11. A comparative study of space radiation organ doses and associated cancer risks using PHITS and HZETRN

    NASA Astrophysics Data System (ADS)

    Bahadori, Amir A.; Sato, Tatsuhiko; Slaba, Tony C.; Shavers, Mark R.; Semones, Edward J.; Van Baalen, Mary; Bolch, Wesley E.

    2013-10-01

    NASA currently uses one-dimensional deterministic transport to generate values of the organ dose equivalent needed to calculate stochastic radiation risk following crew space exposures. In this study, organ absorbed doses and dose equivalents are calculated for 50th percentile male and female astronaut phantoms using both the NASA High Charge and Energy Transport Code to perform one-dimensional deterministic transport and the Particle and Heavy Ion Transport Code System to perform three-dimensional Monte Carlo transport. Two measures of radiation risk, effective dose and risk of exposure-induced death (REID) are calculated using the organ dose equivalents resulting from the two methods of radiation transport. For the space radiation environments and simplified shielding configurations considered, small differences (<8%) in the effective dose and REID are found. However, for the galactic cosmic ray (GCR) boundary condition, compensating errors are observed, indicating that comparisons between the integral measurements of complex radiation environments and code calculations can be misleading. Code-to-code benchmarks allow for the comparison of differential quantities, such as secondary particle differential fluence, to provide insight into differences observed in integral quantities for particular components of the GCR spectrum.

  12. The impact of a stage tailored intervention on alcohol use trajectories among those who do not intend to change.

    PubMed

    Baumann, Sophie; Gaertner, Beate; Schnuerer, Inga; Haberecht, Katja; John, Ulrich; Freyer-Adam, Jennis

    2015-02-01

    Persons not intending to change are an important target population for public health efforts. The aim of this study was to investigate whether subgroups characterized by different trajectories of alcohol use frequency and quantity among persons with unhealthy drinking but no intention to change benefitted differently from a stage tailored intervention. This study was part of a randomized controlled trial among job-seekers. The participants of the intervention group (n=413) received feedback letters tailored to their motivational stage. The control group (n=414) received minimal assessment only. Among all participants, 629 (76.1%) did not intend to change alcohol use and constitute the study sample (60.7% men; mean age=29.7 years, SD=10.8). 3-, 6-, and 15-month follow-ups were conducted. Growth mixture modeling was applied to identify classes representing the heterogeneity in the development of alcohol use frequency and quantity and the influence of the intervention on different trajectories. Four classes were identified: a class of persons who achieved abstinence (2%), a class with low-frequent drinking with declining quantity (35%), a class with high-frequent drinking with low but slightly increasing quantity (30%), and a class with constant heavy episodic drinking (33%). Although non-significant, there was a tendency of different intervention effects for different classes. A sample of persons not intending to change unhealthy alcohol use was composed of subgroups characterized by different trajectories of alcohol use quantity and frequency. Trends towards beneficial intervention effects on motivation and drinking outcomes were not significant, possibly due to low power. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  13. 41 CFR 50-204.20 - Radiation-definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... rad due to particles heavier than protons and with sufficient energy to reach the lens of the eye; (5...) Dose means the quantity of ionizing radiation absorbed, per unit of mass, by the body or by any portion of the body. When the provisions in this subpart specify a dose during a period of time, the dose is...

  14. 41 CFR 50-204.20 - Radiation-definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... rad due to particles heavier than protons and with sufficient energy to reach the lens of the eye; (5...) Dose means the quantity of ionizing radiation absorbed, per unit of mass, by the body or by any portion of the body. When the provisions in this subpart specify a dose during a period of time, the dose is...

  15. 41 CFR 50-204.20 - Radiation-definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... rad due to particles heavier than protons and with sufficient energy to reach the lens of the eye; (5...) Dose means the quantity of ionizing radiation absorbed, per unit of mass, by the body or by any portion of the body. When the provisions in this subpart specify a dose during a period of time, the dose is...

  16. Dose rate constants for the quantity Hp(3) for frequently used radionuclides in nuclear medicine.

    PubMed

    Szermerski, Bastian; Bruchmann, Iris; Behrens, Rolf; Geworski, Lilli

    2016-12-01

    According to recent studies, the human eye lens is more sensitive to ionising radiation than previously assumed. Therefore, the dose limit for personnel occupationally exposed to ionising radiation will be lowered from currently 150 mSv to 20 mSv per year. Currently, no data base for a reliable estimation of the dose to the lens of the eye is available for nuclear medicine. Furthermore, the dose is usually not monitored. The aim of this work was to determine dose rate constants for the quantity H p (3), which is supposed to estimate the dose to the lens of the eye. For this, H p (3)-dosemeters were fixed to an Alderson Phantom at different positions. The dosemeters were exposed to radiation from nuclides typically used in nuclear medicine in their geometries analog to their application in nuclear medicine, e.g. syringe or vial. The results show that the handling of high-energy beta (i.e. electron or positron) emitters may lead to a relevant dose to the lens of the eye. For low-energy beta emitters and gamma emitters, an exceeding of the lowered dose limit seems to be unlikely. Copyright © 2015. Published by Elsevier GmbH.

  17. NOTE: Dose area product evaluations with Gafchromic® XR-R films and a flat-bed scanner

    NASA Astrophysics Data System (ADS)

    Rampado, O.; Garelli, E.; Deagostini, S.; Ropolo, R.

    2006-12-01

    Gafchromic® XR-R films are a useful tool to evaluate entrance skin dose in interventional radiology. Another dosimetric quantity of interest in diagnostic and interventional radiology is the dose area product (DAP). In this study, a method to evaluate DAP using Gafchromic® XR-R films and a flat-bed scanner was developed and tested. Film samples were exposed to an x-ray beam of 80 kVp over a dose range of 0 10 Gy. DAP measurements with films were obtained from the digitalization of a film sample positioned over the x-ray beam window during the exposure. DAP values obtained with this method were compared for 23 cardiological interventional procedures with DAP values displayed by the equipment. The overall one-sigma dose measurement uncertainty depended on the absorbed dose, with values below 6% for doses above 1 Gy. A maximum discrepancy of 16% was found, which is of the order of the differences in the DAP measurements that may occur with different calibration procedures. Based on the results presented, after an accurate calibration procedure and a thorough inspection of the relationship between the actual dose and the direct measured quantity (net optical density or net pixel value variation), Gafchromic® XR-R films can be used to assess the DAP.

  18. [Study on manpower allocation criteria of center of disease prevention and control in the context of province level, city level and county level].

    PubMed

    Luo, Li; Waang, Ying; Sun, Mei; Su, Zhong-Xin; Ma, Ning; Xie, Hongbin; Wang, Weicheng; Yu, Jingjin; Yu, Mingzhu; Duan, Yong; Gong, Xiangguang; Chen, Zheng; Wang, Hua; Shi, Peiwu; Liang, Zhankai; Yang, Feng; Wang, Dunzhi; Yue, Jianning; Luo, Shi; Hao, Mo

    2006-01-01

    To set the manpower allocation criteria of center of disease prevention and control. Expected allocation manpower criteria was obtained through adjusting the current manpower allocation of disease prevention and control centers. The principle was to fulfill public function and promote professional efficiency. Based on function requirement, in 3 - 5 years, the manpower allocation criteria of center of disease prevention and control at provincial-level is 336 persons, at city-level is 102 persons, and at county-level is 33 persons, that means in whole country 140016 persons should be needed. In 10 years, the manpower allocation criteria of center of disease prevention and control at provincial-level is 386 persons, at city-level is 112 persons, and at county-level is 38 persons, that means in whole country 159086 persons should be needed. The manpower allocation criteria advanced in the study indicated that current manpower quantity should be greatly reduced. It is an inevitable trend that disease prevention and control centers reduce the staff quantity and promote their quality.

  19. 'Trafficking' or 'personal use': do people who regularly inject drugs understand Australian drug trafficking laws?

    PubMed

    Hughes, Caitlin E; Ritter, Alison; Cowdery, Nicholas; Sindicich, Natasha

    2014-11-01

    Legal thresholds for drug trafficking, over which possession of an illicit drug is deemed 'trafficking' as opposed to 'personal use', are employed in all Australian states and territories excepting Queensland. In this paper, we explore the extent to which people who regularly inject drugs understand such laws. Participants from the seven affected states/territories in the 2012 Illicit Drug Reporting System (n = 823) were asked about their legal knowledge of trafficking thresholds: whether, if arrested, quantity possessed would affect legal action taken; and the quantities of heroin, methamphetamine, cocaine and cannabis that would constitute an offence of supply. Data were compared against the actual laws to identify the accuracy of knowledge by drug type and state, and sociodemographics, use and purchasing patterns related to knowledge. Most Illicit Drug Reporting System participants (77%) correctly said that quantity possessed would affect charge received. However, only 55.8% nominated any specific quantity that would constitute an offence of supply, and of those 22.6% nominated a wrong quantity, namely a quantity that was larger than the actual quantity for supply (this varied by state and drug). People who regularly inject drugs have significant gaps in knowledge about Australian legal thresholds for drug trafficking, particularly regarding the actual threshold quantities. This suggests that there may be a need to improve education for this population. Necessity for accurate knowledge would also be lessened by better design of Australian drug trafficking laws. © 2014 Australasian Professional Society on Alcohol and other Drugs.

  20. Development of blueberry liquor: influence of distillate, sweetener and fruit quantity.

    PubMed

    Caldeira, Ilda; Lopes, Daniel; Delgado, Teresa; Canas, Sara; Anjos, Ofélia

    2018-02-01

    In this work different formulations of blueberry liquor were tested and characterised based on their physico-chemical and sensory characteristics. Three factors were evaluated: the distillate used to produce the liquor (wine spirit or grape marc spirit); the sweetener (white sugar or honey) and the fruit quantity (two doses). For each liquor, pH, total acidity, dry soluble solids content, dry extract, alcoholic strength, reducing sugars, colour intensity, methanol content, acetaldehyde and fusel alcohols were determined. Sensory tests were carried out with a trained panel. The three factors studied significantly influenced the physico-chemical features of the liquors, being the quantity of fruit the most discriminating factor, except for the volatile compounds which were mainly influenced by the distillate. As regards the sensory analysis, it was found that the most appreciated liquor was that prepared with wine spirit, sugar and a lower dose of blueberry, and the less appreciated formulation was the one made with grape marc spirit, honey and a lower quantity of blueberry. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  1. Quantifying cannabis: A field study of marijuana quantity estimation.

    PubMed

    Prince, Mark A; Conner, Bradley T; Pearson, Matthew R

    2018-06-01

    The assessment of marijuana use quantity poses unique challenges. These challenges have limited research efforts on quantity assessments. However, quantity estimates are critical to detecting associations between marijuana use and outcomes. We examined accuracy of marijuana users' estimations of quantities of marijuana they prepared to ingest and predictors of both how much was prepared for a single dose and the degree of (in)accuracy of participants' estimates. We recruited a sample of 128 regular-to-heavy marijuana users for a field study wherein they prepared and estimated quantities of marijuana flower in a joint or a bowl as well as marijuana concentrate using a dab tool. The vast majority of participants overestimated the quantity of marijuana that they used in their preparations. We failed to find robust predictors of estimation accuracy. Self-reported quantity estimates are inaccurate, which has implications for studying the link between quantity and marijuana use outcomes. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  2. LETTER TO THE EDITOR: Response to 'Patient dose measurements in radiological practices'

    NASA Astrophysics Data System (ADS)

    Zoetelief, J.; Wambersie, A.

    2006-06-01

    A lack of suitable dosimetric quantities for application in diagnostic radiology is noted by Dr Moores. It is concluded by Dr Moores that it is not possible to adhere to the basic principles of the International Commission on Radiation Units and Measurements (ICRU) regarding patient dosimetry in diagnostic radiology due to the extremely wide variety of quantities and units employed. The conclusion of the ICRU on similar observations, however, was that there is a need for harmonization of quantities and terminology for dosimetry in diagnostic and interventional radiology and they established a Report Committee with the aim of formulating an ICRU report on 'dosimetric procedures in diagnostic radiology'. The report produced by this committee entitled 'Patient dosimetry for x rays used in medical imaging' was accepted for publication in December 2005 and is currently at press, and may serve to improve the current situation with regard to patient dose measurement in diagnostic and interventional radiology.

  3. OCCUPATIONAL DOSE DURING ADULT INTERVENTIONAL CARDIOLOGY: FIRST VALUES WITH PERSONAL ACTIVE DOSIMETERS IN CHILE.

    PubMed

    Ubeda, Carlos; Morales, Claudio; Gutiérrez, Diego; Oliveira, Marcus; Manterola, Carlos

    2018-05-11

    The objective of this article is to present initial occupational dose values using digital active personal dosimeters for medical staff during adult interventional cardiology procedures in a public hospital in Chile. Personal dose equivalent Hp(10) over the lead apron of physician, nurse and radiographer were measured during 59 procedures. Mean values of occupational dose Hp(10) per procedure were 47.6, 6.2 and 4.3 μSv for physician, nurse and radiographer, respectively. If no protective tools are used, physician dose can exceed the new eye lens dose limit.

  4. Comparative drug dose and drug combinations in patients that present to hospital due to self-poisoning.

    PubMed

    Armstrong, Thomas M; Davies, Matthew S; Kitching, Gary; Waring, W Stephen

    2012-11-01

    Self-poisoning is a common reason for acute presentation to hospital. Commonly involved drugs have been reported, but few data exist concerning the different combinations of agents or comparative doses ingested. The present study sought to better characterise the typical patterns of drug overdose that may present via the emergency department. Consecutive adults ≥16 years of age that presented to York Hospital owing to self-poisoning were studied for 2010-2011 inclusive. The primary outcome measure was reported dose, expressed as a multiple of the defined daily dose (DDD) to allow comparison between different agents. There were 1024 patients, including 622 women (60.7%), and median age was 32 years (range, 16 to 92 years). Overdose in men was associated with a higher overall quantity of drugs: arithmetic mean of 20 DDD multiples (95% CI, 15-26) versus 13 (11-15), p = 0.001. Overdose involved a single agent only in 538 patients (52.5%). The mean paracetamol dose was 4.0 (95% CI, 3.7-4.3) DDD multiples; the doses of antidepressants (19.4, 17.0-21.7, p < 0.0001) and benzodiazepines (18.0, 12.8-23.2, p < 0.0001) were comparatively higher. The types of agents involved in self-poisoning and common combinations of agents are characterised. Psychotropic medications were ingested in comparatively larger quantities than analgesic agents and had worse clinical outcome. Further work is required to understand the factors that determine the quantity of drug ingested in patients at risk of drug overdose so as to minimise the risk of significant toxicity. © 2012 The Authors Basic & Clinical Pharmacology & Toxicology © 2012 Nordic Pharmacological Society.

  5. [A parallel-plate small volume chamber for dosimetry of fast electrons and its use].

    PubMed

    Markus, B

    1976-12-01

    The ionization chamber described is designed for dosimetry of electron radiation above ca. 100 keV. It is used for the measurement of the cavity ion dose and of the absorbed dose within solid or water phantoms. Its construction corresponds to a flat chamber in accordance with DIN 6800. The cylindric main body is made of plexiglass (diameter 30 mm, height 14 mm) and encompasses the measuring volume being flush with the surface (diameter 5 mm, height 2 mm; chamber window 2.3 mg/cm2; build up cap for measurements in water 236 mg/cm2). The chamber is constructed with regard to its independency on energy and direction of the incidence as well as to the minimization of the remaining influence quantities, thus answering for the accuracy class "reference-class instrument" (+/- 0.5%). The polarity effect and field perturbation effect are to be neglected, the displacement comes to 0.1 mm, the statistical inaccuracy of measurement to 0.1%. The calibration for the chamber was obtained with a 15 MeV electron beam. The calibration factor for the cavity ion dose is constant, not being related to energy, at least in the range of performance from 2 to 15 MeV according to the primary standard used for calibration (graphic double extrapolation chamber). The overall uncertainty of the calibration factor amounts to +/- 1.5% for the cavity ion dose and to +/- 1.8% for the energy dose. Numerical values of all characteristic quantities and influence quantities which correspond to DIN 6817 and also measurement results for the determination of dose and energy are reported.

  6. Aconitum Alkaloid Poisoning Related to the Culinary Uses of Aconite Roots

    PubMed Central

    Chan, Thomas Y. K.

    2014-01-01

    Aconite roots (roots or root tubers of the Aconitum species) are eaten as root vegetables and used to prepare herbal soups and meals, mainly for their purported health benefits. Aconite roots contain aconitine and other Aconitum alkaloids, which are well known cardiotoxins and neurotoxins. To better understand why Aconitum alkaloid poisoning related to the culinary uses of aconite roots can occur and characterize the risks posed by these “food supplements”, relevant published reports were reviewed. From 1995 to 2013, there were eight reports of aconite poisoning after consumption of these herbal soups and meals, including two reports of large clusters of cases (n = 19–45) and two reports of cases (n = 15–156) managed by two hospitals over a period of 4.5 to 5 years. The herbal formulae used did not adhere to the suggested guidelines, with regarding to the doses (50–500 g instead of 3–30 g per person) and types (raw instead of processed) of aconite roots used. The quantities of Aconitum alkaloids involved were huge, taking into consideration the doses of aconite roots used to prepare herbal soups/meals and the amounts of aconite roots and herbal soups/meals consumed. In a large cluster of cases, despite simmering raw “caowu” (the root tuber of A. kusnezoffii) in pork broth for 24 h, all 19 family members who consumed this soup and boiled “caowu” developed poisoning. Severe or even fatal aconite poisoning can occur after consumption of herbal soups and foods prepared from aconite roots. Even prolonged boiling may not be protective if raw preparations and large quantities of aconite roots are used. The public should be warned of the risk of severe poisoning related to the culinary and traditional medicinal uses of aconite roots. PMID:25184557

  7. Aconitum alkaloid poisoning related to the culinary uses of aconite roots.

    PubMed

    Chan, Thomas Y K

    2014-09-02

    Aconite roots (roots or root tubers of the Aconitum species) are eaten as root vegetables and used to prepare herbal soups and meals, mainly for their purported health benefits. Aconite roots contain aconitine and other Aconitum alkaloids, which are well known cardiotoxins and neurotoxins. To better understand why Aconitum alkaloid poisoning related to the culinary uses of aconite roots can occur and characterize the risks posed by these "food supplements", relevant published reports were reviewed. From 1995 to 2013, there were eight reports of aconite poisoning after consumption of these herbal soups and meals, including two reports of large clusters of cases (n = 19-45) and two reports of cases (n = 15-156) managed by two hospitals over a period of 4.5 to 5 years. The herbal formulae used did not adhere to the suggested guidelines, with regarding to the doses (50-500 g instead of 3-30 g per person) and types (raw instead of processed) of aconite roots used. The quantities of Aconitum alkaloids involved were huge, taking into consideration the doses of aconite roots used to prepare herbal soups/meals and the amounts of aconite roots and herbal soups/meals consumed. In a large cluster of cases, despite simmering raw "caowu" (the root tuber of A. kusnezoffii) in pork broth for 24 h, all 19 family members who consumed this soup and boiled "caowu" developed poisoning. Severe or even fatal aconite poisoning can occur after consumption of herbal soups and foods prepared from aconite roots. Even prolonged boiling may not be protective if raw preparations and large quantities of aconite roots are used. The public should be warned of the risk of severe poisoning related to the culinary and traditional medicinal uses of aconite roots.

  8. Analysis and evaluation for consumer goods containing NORM in Korea.

    PubMed

    Jang, Mee; Chung, Kun Ho; Lim, Jong Myoung; Ji, Young Yong; Kim, Chang Jong; Kang, Mun Ja

    2017-08-01

    We analyzed the consumer goods containing NORM by ICP-MS and evaluated the external dose. To evaluate the external dose, we assumed the small room model as irradiation scenario and calculated the specific effective dose rate using MCNPX code. The external doses for twenty goods are less than 1 mSv considering the specific effective dose rates and usage quantities. However, some of them have relatively high dose and the activity concentration limits are necessary as a screening tool. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Modification and characterization of a high-energy photon irradiation facility using nitrogen-16

    NASA Astrophysics Data System (ADS)

    Roy, Tapash Kumar

    This work involves fabrication and characterization of a reactor source of high energy (˜7 MeV) nitrogen-16 photons for application in evaluation of dosimetric responses of personnel devices and portable instruments. The N-16 source has been established by continuously flowing coolant water from the core of a 1 MW research reactor through a cylindrical thin walled aluminium chamber. Dose measurements have been made at selected distances of interest along the depth axis both for with and without a near-air equilibrium wall of polymethyl methacrylate (PMMA) in place. Photon dose and exposure measurements were done using condenser-R ionization chambers with sufficiently thick walls to yield an approximate transient charged particle equilibrium (TCPE) condition. Field areal uniformity was defined using large area Kodak Readypack RP films along with lead foil radiators. Dosimetric quantities of interest include skin dose, eye (lens) dose, and 1 cm deep dose. Measurements were made at selected depths of 7, 300, and 1000 mg cm-2 for specific evaluation of these respective quantities. Photon spectral analysis was performed with a NaI(Tl) scintillation spectrometry system. Additionally, beta radiation measurements, and evaluation of neutron dose contributions to the radiation field were completed.

  10. 40 CFR 747.195 - Triethanolamine salt of a substituted organic acid.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., commerce, importer, impurity, Inventory, manufacturer, person, process, processor, and small quantities... control of the processor. (ii) Distribution in commerce is limited to purposes of export. (iii) The processor or distributor may not use the substance except in small quantities solely for research and...

  11. Redefining relative biological effectiveness in the context of the EQDX formalism: implications for alpha-particle emitter therapy.

    PubMed

    Hobbs, Robert F; Howell, Roger W; Song, Hong; Baechler, Sébastien; Sgouros, George

    2014-01-01

    Alpha-particle radiopharmaceutical therapy (αRPT) is currently enjoying increasing attention as a viable alternative to chemotherapy for targeting of disseminated micrometastatic disease. In theory, αRPT can be personalized through pre-therapeutic imaging and dosimetry. However, in practice, given the particularities of α-particle emissions, a dosimetric methodology that accurately predicts the thresholds for organ toxicity has not been reported. This is in part due to the fact that the biological effects caused by α-particle radiation differ markedly from the effects caused by traditional external beam (photon or electron) radiation or β-particle emitting radiopharmaceuticals. The concept of relative biological effectiveness (RBE) is used to quantify the ratio of absorbed doses required to achieve a given biological response with alpha particles versus a reference radiation (typically a beta emitter or external beam radiation). However, as conventionally defined, the RBE varies as a function of absorbed dose and therefore a single RBE value is limited in its utility because it cannot be used to predict response over a wide range of absorbed doses. Therefore, efforts are underway to standardize bioeffect modeling for different fractionation schemes and dose rates for both nuclear medicine and external beam radiotherapy. Given the preponderant use of external beams of radiation compared to nuclear medicine in cancer therapy, the more clinically relevant quantity, the 2 Gy equieffective dose, EQD2(α/β), has recently been proposed by the ICRU. In concert with EQD2(α/β), we introduce a new, redefined RBE quantity, named RBE2(α/β), as the ratio of the two linear coefficients that characterize the α particle absorbed dose-response curve and the low-LET megavoltage photon 2 Gy fraction equieffective dose-response curve. The theoretical framework for the proposed new formalism is presented along with its application to experimental data obtained from irradiation of a breast cancer cell line. Radiobiological parameters are obtained using the linear quadratic model to fit cell survival data for MDA-MB-231 human breast cancer cells that were irradiated with either α particles or a single fraction of low-LET (137)Cs γ rays. From these, the linear coefficient for both the biologically effective dose (BED) and the EQD2(α/β) response lines were derived for fractionated irradiation. The standard RBE calculation, using the traditional single fraction reference radiation, gave RBE values that ranged from 2.4 for a surviving fraction of 0.82-6.0 for a surviving fraction of 0.02, while the dose-independent RBE2(4.6) value was 4.5 for all surviving fraction values. Furthermore, bioeffect modeling with RBE2(α/β) and EQD2(α/β) demonstrated the capacity to predict the surviving fraction of cells irradiated with acute and fractionated low-LET radiation, α particles and chronic exponentially decreasing dose rates of low-LET radiation. RBE2(α/β) is independent of absorbed dose for α-particle emitters and it provides a more logical framework for data reporting and conversion to equieffective dose than the conventional dose-dependent definition of RBE. Moreover, it provides a much needed foundation for the ongoing development of an α-particle dosimetry paradigm and will facilitate the use of tolerance dose data available from external beam radiation therapy, thereby helping to develop αRPT as a single modality as well as for combination therapies.

  12. Redefining Relative Biological Effectiveness in the Context of the EQDX Formalism: Implications for Alpha-Particle Emitter Therapy.

    PubMed

    Hobbs, Robert F; Howell, Roger W; Song, Hong; Baechler, Sébastien; Sgouros, George

    2013-12-30

    Alpha-particle radiopharmaceutical therapy (αRPT) is currently enjoying increasing attention as a viable alternative to chemotherapy for targeting of disseminated micrometastatic disease. In theory, αRPT can be personalized through pre-therapeutic imaging and dosimetry. However, in practice, given the particularities of α-particle emissions, a dosimetric methodology that accurately predicts the thresholds for organ toxicity has not been reported. This is in part due to the fact that the biological effects caused by α-particle radiation differ markedly from the effects caused by traditional external beam (photon or electron) radiation or β-particle emitting radiopharmaceuticals. The concept of relative biological effectiveness (RBE) is used to quantify the ratio of absorbed doses required to achieve a given biological response with alpha particles versus a reference radiation (typically a beta emitter or external beam radiation). However, as conventionally defined, the RBE varies as a function of absorbed dose and therefore a single RBE value is limited in its utility because it cannot be used to predict response over a wide range of absorbed doses. Therefore, efforts are underway to standardize bioeffect modeling for different fractionation schemes and dose rates for both nuclear medicine and external beam radiotherapy. Given the preponderant use of external beams of radiation compared to nuclear medicine in cancer therapy, the more clinically relevant quantity, the 2 Gy equieffective dose, EQD2(α/β), has recently been proposed by the ICRU. In concert with EQD2(α/β), we introduce a new, redefined RBE quantity, named RBE2(α/β), as the ratio of the two linear coefficients that characterize the α particle absorbed dose-response curve and the low-LET megavoltage photon 2 Gy fraction equieffective dose-response curve. The theoretical framework for the proposed new formalism is presented along with its application to experimental data obtained from irradiation of a breast cancer cell line. Radiobiological parameters are obtained using the linear quadratic model to fit cell survival data for MDA-MB-231 human breast cancer cells that were irradiated with either α particles or a single fraction of low-LET 137 Cs γ rays. From these, the linear coefficient for both the biologically effective dose (BED) and the EQD2(α/β) response lines were derived for fractionated irradiation. The standard RBE calculation, using the traditional single fraction reference radiation, gave RBE values that ranged from 2.4 for a surviving fraction of 0.82-6.0 for a surviving fraction of 0.02, while the dose-independent RBE2(4.6) value was 4.5 for all surviving fraction values. Furthermore, bioeffect modeling with RBE2(α/β) and EQD2(α/β) demonstrated the capacity to predict the surviving fraction of cells irradiated with acute and fractionated low-LET radiation, α particles and chronic exponentially decreasing dose rates of low-LET radiation. RBE2(α/β) is independent of absorbed dose for α-particle emitters and it provides a more logical framework for data reporting and conversion to equieffective dose than the conventional dose-dependent definition of RBE. Moreover, it provides a much needed foundation for the ongoing development of an α-particle dosimetry paradigm and will facilitate the use of tolerance dose data available from external beam radiation therapy, thereby helping to develop αRPT as a single modality as well as for combination therapies.

  13. SU-E-J-53: Dosimetric Evaluation at Volumetric Modulated Arc Therapy for Treatment of Prostate Cancer Using Single Or Double Arcs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silva, D; Salmon, H; Pavan, G

    2014-06-01

    Purpose: Evaluate and compare retrospective prostate treatment plan using Volumetric Modulated Arc Therapy (RapidArc™ - Varian) technique with single or double arcs at COI Group. Methods: Ten patients with present prostate and seminal vesicle neoplasia were replanned as a target treatment volume and a prescribed dose of 78 Gy. A baseline planning, using single arc, was developed for each case reaching for the best result on PTV, in order to minimize the dose on organs at risk (OAR). Maintaining the same optimization objectives used on baseline plan, two copies for optimizing single and double arcs, have been developed. The plansmore » were performed with 10 MV photon beam energy on Eclipse software, version 11.0, making use of Trilogy linear accelerator with Millenium HD120 multileaf collimator. Comparisons on PTV have been performed, such as: maximum, minimum and mean dose, gradient dose, as well as the quantity of monitor units, treatment time and homogeneity and conformity index. OARs constrains dose have been evaluated, comparing both optimizations. Results: Regarding PTV coverage, the difference of the minimum, maximum and mean dose were 1.28%, 0.7% and 0.2% respectively higher for single arc. When analyzed the index of homogeneity found a difference of 0.99% higher when compared with double arcs. However homogeneity index was 0.97% lower on average by using single arc. The doses on the OARs, in both cases, were in compliance to the recommended limits RTOG 0415. With the use of single arc, the quantity of monitor units was 10,1% lower, as well as the Beam-On time, 41,78%, when comparing double arcs, respectively. Conclusion: Concerning the optimization of patients with present prostate and seminal vesicle neoplasia, the use of single arc reaches similar objectives, when compared to double arcs, in order to decrease the treatment time and the quantity of monitor units.« less

  14. Assessing dose of the representative person for the purpose of radiation protection of the public. ICRP publication 101. Approved by the Commission in September 2005.

    PubMed

    2006-01-01

    The Commission intended that its revised recommendations should be based on a simple, but widely applicable, system of protection that would clarify its objectives and provide a basis for the more formal systems needed by operating managers and regulators. The recommendations would establish quantified constraints, or limits, on individual dose from specified sources. These dose constraints apply to actual or representative people who encounter occupational, medical, and public exposures. This report updates the previous guidance for estimating dose to the public. Dose to the public cannot be measured directly and, in some cases, it cannot be measured at all. Therefore, for the purpose of protection of the public, it is necessary to characterise an individual, either hypothetical or specific, whose dose can be used for determining compliance with the relevant dose constraint. This individual is defined as the 'representative person'. The Commission's goal of protection of the public is achieved if the relevant dose constraint for this individual for a single source is met and radiological protection is optimised. This report explains the process of estimating annual dose and recognises that a number of different methods are available for this purpose. These methods range from deterministic calculations to more complex probabilistic techniques. In addition, a mixture of these techniques may be applied. In selecting characteristics of the representative person, three important concepts should be borne in mind: reasonableness, sustainability, and homogeneity. Each concept is explained and examples are provided to illustrate their roles. Doses to the public are prospective (may occur in the future) or retrospective (occurred in the past). Prospective doses are for hypothetical individuals who may or may not exist in the future, while retrospective doses are generally calculated for specific individuals. The Commission recognises that the level of detail afforded by its provision of dose coefficients for six age categories is not necessary in making prospective assessments of dose, given the inherent uncertainties usually associated with estimating dose to the public and with identification of the representative person. It now recommends the use of three age categories for estimating annual dose to the representative person for prospective assessments. These categories are 0-5 years (infant), 6-15 years (child), and 16-70 years (adult). For practical implementation of this recommendation, dose coefficients and habit data for a 1-year-old infant, a 10-year-old child, and an adult should be used to represent the three age categories. In a probabilistic assessment of dose, whether from a planned facility or an existing situation, the Commission recommends that the representative person should be defined such that the probability is less than about 5% that a person drawn at random from the population will receive a greater dose. If such an assessment indicates that a few tens of people or more could receive doses above the relevant constraint, the characteristics of these people need to be explored. If, following further analysis, it is shown that doses to a few tens of people are indeed likely to exceed the relevant dose constraint, actions to modify the exposure should be considered. The Commission recognises the role that stakeholders can play in identifying characteristics of the representative person. Involvement of stakeholders can significantly improve the quality, understanding, and acceptability of the characteristics of the representative person and the resulting estimated dose.

  15. Antipsychotic doses among community-dwelling persons with Alzheimer disease in Finland.

    PubMed

    Taipale, Heidi; Koponen, Marjaana; Tanskanen, Antti; Tolppanen, Anna-Maija; Tiihonen, Jari; Hartikainen, Sirpa

    2014-08-01

    Use of antipsychotics for treatment of behavioral and psychological symptoms of dementia is frequent among persons with Alzheimer disease (AD). Doses used in long-term therapy have not been previously reported. We describe antipsychotic doses used among community-dwelling persons with AD and investigate factors associated with high-dose use. The MEDALZ-2005 (Medication use and Alzheimer disease) cohort is a nationwide sample including all persons with clinically diagnosed AD at the end of year 2005 in Finland (n = 28,093). Data including prescriptions, comorbidities, and hospital discharge diagnoses were collected from nationwide registers. Antipsychotic doses in monotherapy were investigated during 2006 to 2009. Among 8920 antipsychotic users, 4% (n = 336) used antipsychotics with high dose. Typical antipsychotics were more often used with high dose than atypical antipsychotics. High-dose use was associated with younger age (<80 years) (odds ratio [OR], 1.71; 95% confidence interval [CI], 1.36-2.15]), male sex (OR, 1.52; CI, 1.21-1.91), history of psychiatric disorder (OR, 3.25; CI, 2.54-4.15), and inversely associated with Charlson Comorbidity Index score (score 1: OR, 0.74; CI, 0.57-0.97; score ≥2: OR, 0.68; CI, 0.47-0.97). In conclusion, the majority of persons with AD used antipsychotics with low or medium dose. Typical antipsychotics were more often used with high dose than atypical antipsychotics, which indicates a need for precise dosing instructions in the treatment of behavioral and psychological symptoms of dementia. Clinicians should regularly assess dosing levels especially among men and those with history of psychiatric disorder.

  16. Broad Themes of Difference between French and Americans in Attitudes to Food and Other Life Domains: Personal Versus Communal Values, Quantity Versus Quality, and Comforts Versus Joys

    PubMed Central

    Rozin, Paul; Remick, Abigail K.; Fischler, Claude

    2011-01-01

    Analysis of previous literature on the role of food in life in France and the United States suggests some fundamental differences in attitudes which may generalize outside of the food domain. Questionnaire results from French and American adults suggest that, compared to the French, Americans emphasize quantity rather than quality in making choices, Americans have a higher preference for variety, and Americans usually prefer comforts (things that make life easier) over joys (unique things that make life interesting). The American preference for quantity over quality is discussed in terms of the American focus on abundance as opposed to the French preference for moderation. The American preference for variety is reflective of Americans’ more personal as opposed to communal food and other values. PMID:21845184

  17. Broad Themes of Difference between French and Americans in Attitudes to Food and Other Life Domains: Personal Versus Communal Values, Quantity Versus Quality, and Comforts Versus Joys.

    PubMed

    Rozin, Paul; Remick, Abigail K; Fischler, Claude

    2011-01-01

    Analysis of previous literature on the role of food in life in France and the United States suggests some fundamental differences in attitudes which may generalize outside of the food domain. Questionnaire results from French and American adults suggest that, compared to the French, Americans emphasize quantity rather than quality in making choices, Americans have a higher preference for variety, and Americans usually prefer comforts (things that make life easier) over joys (unique things that make life interesting). The American preference for quantity over quality is discussed in terms of the American focus on abundance as opposed to the French preference for moderation. The American preference for variety is reflective of Americans' more personal as opposed to communal food and other values.

  18. Social Networks in the Classroom: Personality Factors as Antecedents of Student Social Capital

    ERIC Educational Resources Information Center

    Seevers, Matthew T.; Johnson, Bryan R.; Darnold, Todd C.

    2015-01-01

    This study examines personality factors as antecedents of student social capital. We hypothesize relationships between two constructs taken from the five-factor model of personality (agreeableness and extraversion) and two variables that reflect a student's social capital (quantity of ties and strength of ties) in an academic setting. Analysis of…

  19. Subjective Well-Being among Young People in Transition to Adulthood

    ERIC Educational Resources Information Center

    Trzcinski, Eileen; Holst, Elke

    2008-01-01

    This study used a nationally representative sample of young people in Germany from the German Socio-Economic Panel to examine how demographic and socio-economic characteristics of the young persons and their parents, personality traits of the young persons, quality and quantity of relationships, the parent's level of life satisfaction, and other…

  20. Protein Quantity and Quality of Safflower Seed Improved by NP Fertilizer and Rhizobacteria (Azospirillum and Azotobacter spp.)

    PubMed Central

    Nosheen, Asia; Bano, Asghari; Yasmin, Humaira; Keyani, Rumana; Habib, Rabia; Shah, Syed T. A.; Naz, Rabia

    2016-01-01

    HIGHLIGHTS Rhizobacteria (Azotobacter spp.) have improved the quality and quantity of safflower seed protein.Protein quality was confirmed by SDS-PAGE and new bands were found in response to different combinations of rhizobacteria and lower doses of fertilizers.The PGPR application has reduced the use of fertilizers upto 50%. Protein is an essential part of the human diet. The aim of this present study was to improve the protein quality of safflower seed by the application of plant growth promoting rhizobacteria (PGPR) in combination with conventional nitrogen and phosphate (NP) fertilizers. The seeds of two safflower cultivars Thori and Saif-32, were inoculated with Azospirillum and Azotobacter and grown under field conditions. Protein content and quality was assessed by crude protein, amino acid analysis, and SDS-PAGE. Seed crude protein and amino acids (methionine, phenylalanine, and glutamic acid) showed significant improvements (55–1250%) by Azotobacter supplemented with a quarter dose of fertilizers (BTQ) at P ≤ 0.05. Additional protein bands were induced in Thori and Saif-32 by BTQ and BTH (Azotobacter supplemented with a half dose of fertilizer) respectively. The Azospirillum in combination with half dose of fertilizer (SPH) and BTQ enhanced both indole acetic acid (IAA) (90%) and gibberellic acid (GA) (23–27%) content in safflower leaf. Taken together, these data suggest that Azospirillum and Azotobacter along with significantly reduced (up to 75%) use of NP fertilizers could improve the quality and quantity of safflower seed protein. PMID:26941744

  1. Optically stimulated Al2O3:C luminescence dosimeters for teletherapy: Hp(10) performance evaluation.

    PubMed

    Hashim, S; Musa, Y; Ghoshal, S K; Ahmad, N E; Hashim, I H; Yusop, M; Bradley, D A; Kadir, A B A

    2018-05-01

    The performance of optically stimulated luminescence dosimeters (OSLDs, Al 2 O 3 :C) was evaluated in terms of the operational quantity of H P (10) in Co-60 external beam teletherapy unit. The reproducibility, signal depletion, and dose linearity of each dosimeter was investigated. For ten repeated readouts, each dosimeter exposed to 50mSv was found to be reproducible below 1.9 ± 3% from the mean value, indicating good reader stability. Meanwhile, an average signal reduction of 0.5% per readout was found. The dose response revealed a good linearity within the dose range of 5-50mSv having nearly perfect regression line with R 2 equals 0.9992. The accuracy of the measured doses were evaluated in terms of operational quantity H P (10), wherein the trumpet curve method was used respecting the 1990 International Commission on Radiological Protection (ICRP) standard. The accuracy of the overall measurements from all dosimeters was discerned to be within the trumpet curve and devoid of outlier. It is established that the achieved OSL Al 2 O 3 :C dosimeters are greatly reliable for equivalent dose assessment. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Singlet oxygen explicit dosimetry to predict long-term local tumor control for BPD-mediated photodynamic therapy

    NASA Astrophysics Data System (ADS)

    Kim, Michele M.; Penjweini, Rozhin; Ong, Yi Hong; Zhu, Timothy C.

    2017-02-01

    Photodynamic therapy (PDT) is a well-established treatment modality for cancer and other malignant diseases; however, quantities such as light fluence, photosensitizer photobleaching rate, and PDT dose do not fully account for all of the dynamic interactions between the key components involved. In particular, fluence rate (Φ) effects are not accounted for, which has a large effect on the oxygen consumption rate. In this preclinical study, reacted singlet oxygen [1O2]rx was investigated as a dosimetric quantity for PDT outcome. The ability of [1O2]rx to predict the long-term local tumor control rate (LCR) for BPD-mediated PDT was examined. Mice bearing radioactivelyinduced fibrosarcoma (RIF) tumors were treated with different in-air fluences (250, 300, and 350 J/cm2) and in-air ϕ (75, 100, and150 mW/cm2) with a BPD dose of 1 mg/kg and a drug-light interval of 3 hours. Treatment was delivered with a collimated laser beam of 1 cm diameter at 690 nm. Explicit dosimetry of initial tissue oxygen concentration, tissue optical properties, and BPD concentration was used to calculate [1O2]rx. Φ was calculated for the treatment volume based on Monte-Carlo simulations and measured tissue optical properties. Kaplan-Meier analyses for LCR were done for an endpoint of tumor volume <= 100 mm3 using four dose metrics: light fluence, photosensitizer photobleaching rate, PDT dose, and [1O2]rx. PDT dose was defined as the product of the timeintegral of photosensitizer concentration and Φ at a 3 mm tumor depth. Preliminary studies show that [1O2]rx better correlates with LCR and is an effective dosimetric quantity that can predict treatment outcome.

  3. 10 CFR 40.22 - Small quantities of source material.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Small quantities of source material. 40.22 Section 40.22 Energy NUCLEAR REGULATORY COMMISSION DOMESTIC LICENSING OF SOURCE MATERIAL General Licenses § 40.22 Small... (15.4 lb) of uranium, removed during the treatment of drinking water, at any one time. A person may...

  4. 75 FR 11608 - Self-Regulatory Organizations; International Securities Exchange, LLC; Notice of Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-11

    ... contingency orders that have no priority on the book. Such orders are maintained in the system and remain....1(d)(3) (Minimum Quantity Orders). Like all-or-none orders, minimum quantity orders are contingency... Interested persons are invited to submit written data, views, and arguments concerning the foregoing...

  5. 7 CFR 6.23 - Eligibility to apply for a license.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... quantities and number of shipments required under (A) or (B) above. (2) Certain butter. A person issued a nonhistorical license for butter for the 1997 or 1998 quota year may annually apply for a historical license (Appendix 1) for the same quantity of butter for the subsequent quota year and each year thereafter...

  6. 7 CFR 6.23 - Eligibility to apply for a license.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... quantities and number of shipments required under (A) or (B) above. (2) Certain butter. A person issued a nonhistorical license for butter for the 1997 or 1998 quota year may annually apply for a historical license (Appendix 1) for the same quantity of butter for the subsequent quota year and each year thereafter...

  7. 7 CFR 6.23 - Eligibility to apply for a license.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... quantities and number of shipments required under (A) or (B) above. (2) Certain butter. A person issued a nonhistorical license for butter for the 1997 or 1998 quota year may annually apply for a historical license (Appendix 1) for the same quantity of butter for the subsequent quota year and each year thereafter...

  8. 7 CFR 6.23 - Eligibility to apply for a license.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... quantities and number of shipments required under (A) or (B) above. (2) Certain butter. A person issued a nonhistorical license for butter for the 1997 or 1998 quota year may annually apply for a historical license (Appendix 1) for the same quantity of butter for the subsequent quota year and each year thereafter...

  9. Extensions to the Beta Secondary Standard BSS 2

    NASA Astrophysics Data System (ADS)

    Behrens, R.; Buchholz, G.

    2011-11-01

    Since several years, the irradiation facility for beta radiation, the Beta Secondary Standard BSS 2 developed at PTB, has been in worldwide use for the performance of irradiations with calibrated beta sources. Due to recent developments in eye tumor therapy, in eye lens dosimetry, and in soft- and hardware technology, several extensions have been added to the BSS 2. These extensions are described in this paper: 1. The possibility of using a 106Ru/106Rh beta source was added as this radionuclide is often used in tumor therapy. 2. The (small) contribution due to photon radiation was included in the dose (rate) reported by the BSS 2, as this was missing in the past. 3. The quantity personal dose equivalent at a depth of 3 mm, Hp(3), was implemented due to recent findings on the radio sensitivity of the eye lens regarding cataract induction and the subsequent lowering of the dose limit from 150 mSv down to 20 mSv per year; 4. The correction for ambient conditions (air temperature, pressure, and relative humidity) was improved in order to adequately handle the quantity Hp(3) and in order to extend the range of use beyond 25°C. 5. A checksum test was added to the software to secure the calibration data against (un)intended changes. 6. The connection of the PC and the BSS 2 has been changed to a network interface (TCP/IP) in order to be able to use up-to-date computers not containing a parallel and a serial port. 7. A rod phantom was added in order to make sure the mechanical set-up is of high quality. All these extensions have been implemented in the PTB's BSS 2 model. The routine implementation of extension 1 is still under investigation by the manufacturer. The commercially available BSS 2 will contain extensions 2 to 6 starting approximately in 2012, while extension 7 has already been incorporated since 2011. Extensions 2 to 4 will also be available for old BSS 2 versions via a software update, starting approximately at the beginning of 2012. Extension 6 will be available via hardware change by the manufacturer.

  10. SU-F-T-193: Evaluation of a GPU-Based Fast Monte Carlo Code for Proton Therapy Biological Optimization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taleei, R; Qin, N; Jiang, S

    2016-06-15

    Purpose: Biological treatment plan optimization is of great interest for proton therapy. It requires extensive Monte Carlo (MC) simulations to compute physical dose and biological quantities. Recently, a gPMC package was developed for rapid MC dose calculations on a GPU platform. This work investigated its suitability for proton therapy biological optimization in terms of accuracy and efficiency. Methods: We performed simulations of a proton pencil beam with energies of 75, 150 and 225 MeV in a homogeneous water phantom using gPMC and FLUKA. Physical dose and energy spectra for each ion type on the central beam axis were scored. Relativemore » Biological Effectiveness (RBE) was calculated using repair-misrepair-fixation model. Microdosimetry calculations were performed using Monte Carlo Damage Simulation (MCDS). Results: Ranges computed by the two codes agreed within 1 mm. Physical dose difference was less than 2.5 % at the Bragg peak. RBE-weighted dose agreed within 5 % at the Bragg peak. Differences in microdosimetric quantities such as dose average lineal energy transfer and specific energy were < 10%. The simulation time per source particle with FLUKA was 0.0018 sec, while gPMC was ∼ 600 times faster. Conclusion: Physical dose computed by FLUKA and gPMC were in a good agreement. The RBE differences along the central axis were small, and RBE-weighted dose difference was found to be acceptable. The combined accuracy and efficiency makes gPMC suitable for proton therapy biological optimization.« less

  11. 7 CFR 1901.202 - Nondiscrimination in FmHA or its successor agency under Public Law 103-354 programs.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... person or cause any person to be subjected to discrimination on the ground of race, color, or national... unequal treatment in priority, quality, quantity, methods, or charges for service, use, occupancy or... criteria or methods of administration that have the effect of subjecting a person to discrimination with...

  12. 7 CFR 1901.202 - Nondiscrimination in FmHA or its successor agency under Public Law 103-354 programs.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... person or cause any person to be subjected to discrimination on the ground of race, color, or national... unequal treatment in priority, quality, quantity, methods, or charges for service, use, occupancy or... criteria or methods of administration that have the effect of subjecting a person to discrimination with...

  13. 7 CFR 1901.202 - Nondiscrimination in FmHA or its successor agency under Public Law 103-354 programs.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... person or cause any person to be subjected to discrimination on the ground of race, color, or national... unequal treatment in priority, quality, quantity, methods, or charges for service, use, occupancy or... criteria or methods of administration that have the effect of subjecting a person to discrimination with...

  14. 7 CFR 1901.202 - Nondiscrimination in FmHA or its successor agency under Public Law 103-354 programs.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... person or cause any person to be subjected to discrimination on the ground of race, color, or national... unequal treatment in priority, quality, quantity, methods, or charges for service, use, occupancy or... criteria or methods of administration that have the effect of subjecting a person to discrimination with...

  15. 7 CFR 1901.202 - Nondiscrimination in FmHA or its successor agency under Public Law 103-354 programs.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... person or cause any person to be subjected to discrimination on the ground of race, color, or national... unequal treatment in priority, quality, quantity, methods, or charges for service, use, occupancy or... criteria or methods of administration that have the effect of subjecting a person to discrimination with...

  16. 27 CFR 24.75 - Wine for personal or family use.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... family use. 24.75 Section 24.75 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE... Wine § 24.75 Wine for personal or family use. (a) General. Any adult may, without payment of tax, produce wine for personal or family use and not for sale. (b) Quantity. The aggregate amount of wine that...

  17. 30 CFR 75.313 - Main mine fan stoppage with persons underground.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Main mine fan stoppage with persons underground... mine fan stoppage with persons underground. (a) If a main mine fan stops while anyone is underground and the ventilating quantity provided by the fan is not maintained by a back-up fan system— (1...

  18. Dose Comparisons for a Site-specific Representative Person Using the Age-dependent Dose Coefficients in CAP88-PC Version 4.

    PubMed

    Stagich, Brooke H; Moore, Kelsey R; Newton, Joseph R; Dixon, Kenneth L; Jannik, G Timothy

    2017-04-01

    Most U.S. Department of Energy (DOE) facilities with radiological airborne releases use the U.S. Environmental Protection Agency's (EPA) environmental dosimetry code CAP88-PC to demonstrate compliance with regulations in 40CFR61, subpart H [National Emission Standards for Hazardous Air Pollutants: Radiological (NESHAP)]. In 2015, EPA released Version 4 of CAP88-PC, which included significant modifications that improved usability and age-dependent dose coefficients and usage factors for six age groups (infant, 1 y, 5 y, 10 y, 15 y, and adult). However, EPA has not yet provided specific guidance on how to use these age-dependent factors. For demonstrating compliance with DOE public dose regulations, the Savannah River Site (SRS) recently changed from using the maximally exposed individual (MEI) concept (adult male) to the representative person concept (age- and gender-averaged reference person). In this study, dose comparisons are provided between the MEI and a SRS-specific representative person using the age-specific dose coefficients and usage factors in CAP88-PC V.4. Dose comparisons also are provided for each of the six age groups using five radionuclides of interest at SRS (tritium oxide, Cs, Sr, Pu, and I). In general, the total effective dose increases about 11% for the representative person as compared to the current NESHAP MEI because of the inclusion of the more radiosensitive age groups.

  19. Oral penicillin prescribing for children in the UK: a comparison with BNF for Children age-band recommendations

    PubMed Central

    Saxena, Sonia; Ismael, Zareen; Murray, Macey L; Barker, Charlotte; Wong, Ian CK; Sharland, Mike; Long, Paul F

    2014-01-01

    Background The British National Formulary for Children (BNFC) recommends dosing oral penicillins according to age-bands, weight-bands, or weight-based calculations. Because of the rising prevalence of childhood obesity, age-band-based prescribing could lead to subtherapeutic dosing. Aim To investigate actual oral penicillin prescribing by GPs in the UK with reference to the current BNFC age-band recommendations. Design and setting Descriptive analysis of UK prescriptions in the 2010 IMS Disease-Analyzer database (IMS-DA). Method A detailed database analysis was undertaken of oral penicillin prescriptions for 0–18 year olds from the 2010 IMS-DA. The prescription analysis included all available data on formulation, strength (mg), prescription quantity unit, package size, prescribed quantity, and volume. Results Considering amoxicillin alone, no infants (aged <1 year) were prescribed the BNFC 2011 edition recommended unit dose (62.5 mg), while the majority received double the dose (125 mg); among children aged 1–5 years, 96% were prescribed the recommended unit dose (125 mg), but 40% of 6–12 year olds and 70% of 12–18 year olds were prescribed unit doses below the BNFC recommendations. For otitis media, only those children aged <1 year received the recommended dose of amoxicillin (40–90 mg/kg/day). Similar variations in dosing across age-bands were observed for phenoxymethylpenicillin and flucloxacillin. Conclusion There is wide variation in the dosing of penicillins for children in UK primary care, with very few children being prescribed the current national recommended doses. There is an urgent need to review dosing guidelines, in relation to the weights of children today. PMID:24686886

  20. Methodological issues using household budget survey expenditure data for individual food availability estimation: Irish experience in the DAFNE pan-European project. DAta Food NEtworking.

    PubMed

    Friel, S; Nelson, M; McCormack, K; Kelleher, C; Thriskos, P

    2001-10-01

    Irish participation in the EU-supported DAta Food NEtworking (DAFNE) project required compliance with the overall aims and objectives. The Irish Household Budget Survey (HBS) expenditure data had to be transformed into a format compatible with the collaborative effort, by converting them into quantities of foodstuffs available per person per day. The Irish 1987 HBS expenditure data on all commodities for 7705 households in the Republic of Ireland, collected using a 14-day diary kept by all members of the household aged 15 years and over. Following identification of 188 food items in the HBS dataset, retail prices per unit weight were sought for each food. Adjustment of prices, collected from a number of different sources, was made to those of 1987 using the Consumer Price Index. Simple models were used to estimate household food availability through application of the adjusted retail prices per unit weight to the expenditure data. The household level data were converted to food availability per person per day. An internal validation of quantities estimated using the retail prices was made using the 12 foodstuffs for which the Irish HBS collects expenses and quantities. The comparison of quantities published by the Irish Central Statistics Office for 12 foodstuffs in the Irish 1987 Household Budget Survey with the quantities estimated using equivalent expenditure data and corresponding retail prices showed agreement, with less than a 10% margin of error for 10 of the foods. In spite some difficulty in converting HBS food expenditure data into food availability per person per day, the DAFNE approach is potentially useful for Irish nutrition surveillance purposes and for facilitating comparisons of the Irish HBS food data with those of other European countries.

  1. ON THE EFFECT OF SMALL DOSE X RADIATION ON SEPTICEMIA CAUSED BY PNEUMONIAE FRIEDLANDER. PART II. THE EFFECT OF SMALL TOTAL DOSE X RADIATION ON A SUBCUTANEOUS INFECTION (in German)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Birkner, R.; Meyer, R.; Trautmann, J.

    1957-01-01

    ABS>The effect of small doses of whole-body x radiation on the septicemia caused by Klebsiella pneumoniac Friedlander in white mice depends on the moment of the irradiation, the dose, the temporal dose distribution, the age and the sex of the animals, as well as on the quantity of germs applied. Animals die more rapidly if irradiations have been applied previous to the infection, while irradiations after infections lead to longer life. (auth)

  2. Personal radiofrequency electromagnetic field exposure measurements in Swiss adolescents.

    PubMed

    Roser, Katharina; Schoeni, Anna; Struchen, Benjamin; Zahner, Marco; Eeftens, Marloes; Fröhlich, Jürg; Röösli, Martin

    2017-02-01

    Adolescents belong to the heaviest users of wireless communication devices, but little is known about their personal exposure to radiofrequency electromagnetic fields (RF-EMF). The aim of this paper is to describe personal RF-EMF exposure of Swiss adolescents and evaluate exposure relevant factors. Furthermore, personal measurements were used to estimate average contributions of various sources to the total absorbed RF-EMF dose of the brain and the whole body. Personal exposure was measured using a portable RF-EMF measurement device (ExpoM-RF) measuring 13 frequency bands ranging from 470 to 3600MHz. The participants carried the device for three consecutive days and kept a time-activity diary. In total, 90 adolescents aged 13 to 17years participated in the study conducted between May 2013 and April 2014. In addition, personal measurement values were combined with dose calculations for the use of wireless communication devices to quantify the contribution of various RF-EMF sources to the daily RF-EMF dose of adolescents. Main contributors to the total personal RF-EMF measurements of 63.2μW/m 2 (0.15V/m) were exposures from mobile phones (67.2%) and from mobile phone base stations (19.8%). WLAN at school and at home had little impact on the personal measurements (WLAN accounted for 3.5% of total personal measurements). According to the dose calculations, exposure from environmental sources (broadcast transmitters, mobile phone base stations, cordless phone base stations, WLAN access points, and mobile phones in the surroundings) contributed on average 6.0% to the brain dose and 9.0% to the whole-body dose. RF-EMF exposure of adolescents is dominated by their own mobile phone use. Environmental sources such as mobile phone base stations play a minor role. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Dose commitments due to radioactive releases from nuclear power plant sites in 1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.

    Population and individual radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1989. Fifty-year dose commitments for a one-year exposure from both liquid and atmospheric releases were calculated for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 72 reactor sites. This report tabulates the results of these calculations, showing the dose commitments for both water and airborne pathways for each age group and organ. Also included for each of the sites is an estimate of individual doses which are compared with 10 CFR Partmore » 50, Appendix I design objectives. The total collective dose commitments (from both liquid and airborne pathways) for each site ranged from a high of 14 person-rem to a low of 0.005 person-rem for the sites with plants in operation and producing power during the year. The arithmetic mean was 1.2 person-rem. The total population dose for all sites was estimated at 84 person-rem for the 140 million people considered at risk. The individual dose commitments estimated for all sites were below the Appendix I design objectives.« less

  4. Population dose commitments due to radioactive releases from nuclear power plant sites in 1980

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.; Peloquin, R.A.

    Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1980. In addition doses derived from the shutdown reactors at the Three Mile Island site were included. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each site. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ. Also included for each site is a histogram showingmore » the fraction of the total population within 2 to 80 km around each site receiving various average dose commitments from the airborne pathways. The total dose commitment from both liquid and airborne pathways ranged from a high of 40 person-rem to a low of 0.02 person-rem with an arithmetic mean of 4 person-rem. The total population dose for all sites was estimated at 180 person-rem for the 96 million people considered at risk.« less

  5. Dose commitments due to radioactive releases from nuclear power plant sites in 1989. Volume 11

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.

    Population and individual radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1989. Fifty-year dose commitments for a one-year exposure from both liquid and atmospheric releases were calculated for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 72 reactor sites. This report tabulates the results of these calculations, showing the dose commitments for both water and airborne pathways for each age group and organ. Also included for each of the sites is an estimate of individual doses which are compared with 10 CFR Partmore » 50, Appendix I design objectives. The total collective dose commitments (from both liquid and airborne pathways) for each site ranged from a high of 14 person-rem to a low of 0.005 person-rem for the sites with plants in operation and producing power during the year. The arithmetic mean was 1.2 person-rem. The total population dose for all sites was estimated at 84 person-rem for the 140 million people considered at risk. The individual dose commitments estimated for all sites were below the Appendix I design objectives.« less

  6. [Personal dose monitoring of radiation workers in medical institutions at the municipal level and below in a city from 2011 to 2014].

    PubMed

    Wang, C; Mo, S F; Zhang, J B; Li, J R; Huang, R L; Tan, H Y

    2017-08-20

    Objective: To determine the personal dose level of radiation workers in medical institutions at the municipal level and below in a city, and to provide a scientific support for strengthening the radiation protection in the city's medical institutions. Methods: Information of the successful applicants for the "Radiation Worker Permit" from 174 medical institutions at the municipal level and below was collected from October 1, 2011 to December 31, 2014. The annual effective dose was calculated based on the personal dose monitoring report, and indicators including sex, permit application time, hospital level, type of occupational radiation, length of radiation work, blood test, and micronucleated lymphocyte rate were analyzed. Results: Of the 1 143 radiation worker permit applications submitted by medical institutions the municipal level and below in this city from 2011 to 2014, 1 123 provided at least one personal dose monitoring report. The annual effective dose of the radiation workers was 0-4.76 mSv (mean 0.31±0.40 mSv) , and the collective annual effective dose was 351.96 mSv. The annual effective dose was significantly different between radiation workers with different times of permit application, hospital levels, and types of occupational radiation ( P <0.05) . Interventional radiology workers had the highest annual effective dose (0.63 mSv) , and annual effective dose was significantly different between interventional radiology workers with different lengths of radiation work ( H =10.812, P <0.05) . Conclusion: The personal radiation dose of radiation workers in medical institutions at the municipal level and below in this city is maintained at a relatively low level, suggesting that the occupational environment is relatively safe for these workers. However, more focus should be placed on clinical interventional radiology workers.

  7. Individual dose monitoring of the nuclear medicine departments staff controlled by Central Laboratory for Radiological Protection.

    PubMed

    Szewczak, Kamil; Jednoróg, Sławomir; Krajewski, Paweł

    2013-01-01

    Presented paper describes the results of the individual doses measurements for ionizing radiation, carried out by the Laboratory of Individual and Environmental Doses Monitoring (PDIS) of the Central Laboratory for Radiological Protection in Warsaw (CLOR) for the medical staff employees in several nuclear medicine (NM) departments across Poland. In total there are48 NM departments in operation in Poland [1] (consultation in Nuclear Atomic Agency). Presented results were collected over the period from January 2011 to December 2011 at eight NM departments located in Krakow, Warszawa (two departments), Rzeszow (two departments), Opole, Przemysl and Gorzow Wielkopolski. For radiation monitoring three kinds of thermo luminescence dosimeters (TLD) were used. The first TLD h collected information about whole body (C) effective dose, the second dosimeter was mounted in the ring (P) meanwhile the third on the wrist (N) of the tested person. Reading of TLDs was performed in quarterly periods. As a good approximation of effective and equivalent dose assessment of operational quantities both the individual dose equivalent Hp(10) and the Hp(0.07) were used. The analysis of the data was performed using two methods The first method was based on quarterly estimations of Hp(10)q and Hp(0.07)q while the second measured cumulative annual doses Hp(10)a and Hp(0.07)a. The highest recorded value of the radiation dose for quarterly assessments reached 24.4 mSv and was recorded by the wrist type dosimeter worn by a worker involved in source preparation procedure. The mean values of Hp(10)q(C type dosimeter) and Hp(0.07)q (P and N type dosimeter) for all monitored departments were respectively 0.46 mSv and 3.29 mSv. There was a strong correlation between the performed job and the value of the received dose. The highest doses always were absorbed by those staff members who were involved in sources preparation. The highest annual cumulative dose for a particular worker in the considered time period was 4.22 mSv for Hp(10)a and 67.7 mSv for Hp(0.07)a. In 2011 no case of exceeding the allowed dose limits was noted.

  8. Alcohol-Related Negative Consequences among Drinkers around the World

    PubMed Central

    Graham, Kathryn; Bernards, Sharon; Knibbe, Ronald; Kairouz, Sylvia; Kuntche, Sandra; Wilsnack, Sharon C.; Greenfield, Thomas K.; Dietze, Paul; Obot, Isidore; Gmel, Gerhard

    2013-01-01

    Aims This paper examines (1) gender and country differences in negative consequences related to drinking; (2) relative rates of different consequences; (3) country-level predictors of consequences. Design, setting and participants Multi-level analyses used survey data from the GENACIS collaboration. Measurements Measures included 17 negative consequences grouped into (a) high endorsement acute, (b) personal and (c) social. Country-level measures included average frequency and quantity of drinking, percent current drinkers, Gross Domestic Product (GDP) and Human Development Index (HDI). Findings Overall, the three groupings of consequences were reported by 44%, 12% and 7% of men and by 31%, 6% and 3% of women, respectively. More men than women endorsed all consequences but gender differences were greatest for consequences associated with chronic drinking and social consequences related to male roles. The highest prevalence of consequences was in Uganda, lowest in Uruguay. Personal and social consequences were more likely in countries with higher usual quantity, fewer current drinkers, and lower scores on GDP and HDI. However, significant interactions with individual-level quantity indicated a stronger relationship between consequences and usual quantity among drinkers in countries with lower quantity, more current drinkers and higher scores on GDP and HDI. Conclusions Both gender and country need to be taken into consideration when assessing adverse drinking consequences. Individual measures of alcohol consumption and country-level variables are associated with experiencing such consequences. Additionally, country-level variables affect the strength of the relationship between usual quantity consumed by individuals and adverse consequences. PMID:21395893

  9. Micron MT29F128G08AJAAA 128GB Asynchronous Flash Memory Total Ionizing Dose Characterization Test Report

    NASA Technical Reports Server (NTRS)

    Campola, Michael; Wyrwas, Edward

    2017-01-01

    The purpose of this test was to characterize the Micron MT29F128G08AJAAAs parameter degradation for total dose response and to evaluate and compare lot date codes for sensitivity. In the test, the device was exposed to both low dose and high dose rate (HDR) irradiations using gamma radiation. Device parameters such as leakage currents, quantity of upset bits and overall chip and die health were investigated to determine which lot is more robust.

  10. A proposed performance index for galactic cosmic ray shielding materials

    NASA Technical Reports Server (NTRS)

    Wilson, John W.; Wood, J. S.; Shinn, Judy L.; Cucinotta, Francis A.; Nealy, John E.

    1993-01-01

    In past studies, the reductions in absorbed dose and dose equivalent due to choice of material composition have been used to indicate shield effectiveness against exposure to galactic cosmic rays. However, these quantities are highly inaccurate in assessing shield effectiveness for protection against the biological effects of long-term exposure to the galactic heavy ions. A new quantity for shield performance is defined that correlates well with cell killing and cell transformation behind various shield thicknesses and materials. In addition, a relative performance index is identified that is inversely related to biological injury for different materials at a fixed shield mass and is directly related to the ratio of the fourth- and the second-order linear energy transfer (LET) moments.

  11. 40 CFR 82.20 - Availability of consumption allowances in addition to baseline consumption allowances for class...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... period some quantity of consumption that the nation is permitted under the Montreal Protocol. (2) Trade... Party to the Protocol as set forth in this paragraph (b). A person may only receive consumption from... maximum consumption that the nation is allowed under the Protocol minus the quantity (in kilograms) traded...

  12. 40 CFR 82.20 - Availability of consumption allowances in addition to baseline consumption allowances for class...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... period some quantity of consumption that the nation is permitted under the Montreal Protocol. (2) Trade... Party to the Protocol as set forth in this paragraph (b). A person may only receive consumption from... maximum consumption that the nation is allowed under the Protocol minus the quantity (in kilograms) traded...

  13. 40 CFR 82.20 - Availability of consumption allowances in addition to baseline consumption allowances for class...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... period some quantity of consumption that the nation is permitted under the Montreal Protocol. (2) Trade... Party to the Protocol as set forth in this paragraph (b). A person may only receive consumption from... maximum consumption that the nation is allowed under the Protocol minus the quantity (in kilograms) traded...

  14. 40 CFR 82.20 - Availability of consumption allowances in addition to baseline consumption allowances for class...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... period some quantity of consumption that the nation is permitted under the Montreal Protocol. (2) Trade... Party to the Protocol as set forth in this paragraph (b). A person may only receive consumption from... maximum consumption that the nation is allowed under the Protocol minus the quantity (in kilograms) traded...

  15. 40 CFR 82.20 - Availability of consumption allowances in addition to baseline consumption allowances for class...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... period some quantity of consumption that the nation is permitted under the Montreal Protocol. (2) Trade... Party to the Protocol as set forth in this paragraph (b). A person may only receive consumption from... maximum consumption that the nation is allowed under the Protocol minus the quantity (in kilograms) traded...

  16. 21 CFR 1303.22 - Procedure for applying for individual manufacturing quotas.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... manufacturing quotas. Any person who is registered to manufacture any basic class of controlled substance listed in Schedule I or II and who desires to manufacture a quantity of such class shall apply on DEA Form 189 for a manufacturing quota for such quantity of such class. Copies of DEA Form 189 may be obtained...

  17. The use of TLD-700H dosemeters in the assessment of external doses at the former Semipalatinsk nuclear test site.

    PubMed

    Hill, P; Dederichs, H; Pillath, J; Schlecht, W; Hille, R; Artemev, O; Ptitskaya, L; Akhmetov, M

    2002-01-01

    The joint projects performed since 1995 by the Jülich Research Centre in co-operation with the Kazakh National Nuclear Centre in the area of the former nuclear test site near Semipalatinsk, in eastern Kazakhstan, have assessed the current dose rate of the population at and around the test site, as well as determining retrospectively the dose rate of persons affected by the atmospheric tests. Measurements of the population by personal dosemeters depend on reliably wearing these dosemeters over prolonged periods of time, and of a sufficient dosemeter return. In the past, such measurements have been particularly successful whenever short wearing times were possible. This requires high sensitivity of the dosemeters. The suitability of the highly sensitive TLD material of the BICRON TLD 700H type for such personal dosimetry measurements was investigated. It was tested in practical field application at the Semipalatinsk nuclear test site in September 2000. Initial results are available from individual doses received by a group of geologists and a group of herdsmen at the test site. For the first time, the individual dose was measured directly in these population groups. Detection limits below 1 microSv permit informative measurements for wearing times of less than two weeks. Most individual doses did not arise significantly out of local fluctuations of natural background. A conservative assessment from the aspect of practical health physics yielded a mean personal dose of 0.55 microSv per day for the herdsmen, whereas the geologists received a mean personal dose of 0.45 microSv per day. For an annual exposure period of typically, about three months, the radiation dose received by the persons investigated, in addition to the natural radiation exposure, is thus well below the international limit value of 1 mSv x a(-1) for the population dose.

  18. 41 CFR 50-204.20 - Radiation-definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the lens of the eye; (5) If it is more convenient to measure the neutron flux, or equivalent, than to... materials. (e) Dose means the quantity of ionizing radiation absorbed, per unit of mass, by the body or by any portion of the body. When the provisions in this subpart specify a dose during a period of time...

  19. 41 CFR 50-204.20 - Radiation-definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the lens of the eye; (5) If it is more convenient to measure the neutron flux, or equivalent, than to... materials. (e) Dose means the quantity of ionizing radiation absorbed, per unit of mass, by the body or by any portion of the body. When the provisions in this subpart specify a dose during a period of time...

  20. Proof of concept for a banding scheme to support risk assessments related to multi-product biologics manufacturing.

    PubMed

    Card, Jeffrey W; Fikree, Hana; Haighton, Lois A; Blackwell, James; Felice, Brian; Wright, Teresa L

    2015-11-01

    A banding scheme theory has been proposed to assess the potency/toxicity of biologics and assist with decisions regarding the introduction of new biologic products into existing manufacturing facilities. The current work was conducted to provide a practical example of how this scheme could be applied. Information was identified for representatives from the following four proposed bands: Band A (lethal toxins); Band B (toxins and apoptosis signals); Band C (cytokines and growth factors); and Band D (antibodies, antibody fragments, scaffold molecules, and insulins). The potency/toxicity of the representative substances was confirmed as follows: Band A, low nanogram quantities exert lethal effects; Band B, repeated administration of microgram quantities is tolerated in humans; Band C, endogenous substances and recombinant versions administered to patients in low (interferons), intermediate (growth factors), and high (interleukins) microgram doses, often on a chronic basis; and Band D, endogenous substances present or produced in the body in milligram quantities per day (insulin, collagen) or protein therapeutics administered in milligram quantities per dose (mAbs). This work confirms that substances in Bands A, B, C, and D represent very high, high, medium, and low concern with regard to risk of cross-contamination in manufacturing facilities, thus supporting the proposed banding scheme. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. OFFICE RADIOBIOLOGY AND THE TEST OF DIVIDED-DOSE IRRADIATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scanlon, P.W.

    1963-08-01

    A simple and quantitatively accurate radiobiologic test system for office use by the clinical radiotherapist is described. Radiation inhibition of Lemna minor, or duckweed grown in an aquarium, forms the basis of the test system. Results are reported from radiation-inhibition studies using this system with time-dose variables appropriate to the radiation dose. The system proved adequate for testing the relative biologic effectiveness of the various quantities of radiation employed in clinical radiotherapy. (C.H.)

  2. PACKAGING CERTIFICATION PROGRAM METHODOLOGY FOR DETERMINING DOSE RATES FOR SMALL GRAM QUANTITIES IN SHIPPING PACKAGINGS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nathan, S.; Loftin, B.; Abramczyk, G.

    The Small Gram Quantity (SGQ) concept is based on the understanding that small amounts of hazardous materials, in this case radioactive materials (RAM), are significantly less hazardous than large amounts of the same materials. This paper describes a methodology designed to estimate an SGQ for several neutron and gamma emitting isotopes that can be shipped in a package compliant with 10 CFR Part 71 external radiation level limits regulations. These regulations require packaging for the shipment of radioactive materials, under both normal and accident conditions, to perform the essential functions of material containment, subcriticality, and maintain external radiation levels withinmore » the specified limits. By placing the contents in a helium leak-tight containment vessel, and limiting the mass to ensure subcriticality, the first two essential functions are readily met. Some isotopes emit sufficiently strong photon radiation that small amounts of material can yield a large dose rate outside the package. Quantifying the dose rate for a proposed content is a challenging issue for the SGQ approach. It is essential to quantify external radiation levels from several common gamma and neutron sources that can be safely placed in a specific packaging, to ensure compliance with federal regulations. The Packaging Certification Program (PCP) Methodology for Determining Dose Rate for Small Gram Quantities in Shipping Packagings provides bounding shielding calculations that define mass limits compliant with 10 CFR 71.47 for a set of proposed SGQ isotopes. The approach is based on energy superposition with dose response calculated for a set of spectral groups for a baseline physical packaging configuration. The methodology includes using the MCNP radiation transport code to evaluate a family of neutron and photon spectral groups using the 9977 shipping package and its associated shielded containers as the base case. This results in a set of multipliers for 'dose per particle' for each spectral group. For a given isotope, the source spectrum is folded with the response for each group. The summed contribution from all isotopes determines the total dose from the RAM in the container.« less

  3. Measurements and simulations of the radiation exposure to aircraft crew workplaces due to cosmic radiation in the atmosphere.

    PubMed

    Beck, P; Latocha, M; Dorman, L; Pelliccioni, M; Rollet, S

    2007-01-01

    As required by the European Directive 96/29/Euratom, radiation exposure due to natural ionizing radiation has to be taken into account at workplaces if the effective dose could become more than 1 mSv per year. An example of workers concerned by this directive is aircraft crew due to cosmic radiation exposure in the atmosphere. Extensive measurement campaigns on board aircrafts have been carried out to assess ambient dose equivalent. A consortium of European dosimetry institutes within EURADOS WG5 summarized experimental data and results of calculations, together with detailed descriptions of the methods for measurements and calculations. The radiation protection quantity of interest is the effective dose, E (ISO). The comparison of results by measurements and calculations is done in terms of the operational quantity ambient dose equivalent, H(10). This paper gives an overview of the EURADOS Aircraft Crew In-Flight Database and it presents a new empirical model describing fitting functions for this data. Furthermore, it describes numerical simulations performed with the Monte Carlo code FLUKA-2005 using an updated version of the cosmic radiation primary spectra. The ratio between ambient dose equivalent and effective dose at commercial flight altitudes, calculated with FLUKA-2005, is discussed. Finally, it presents the aviation dosimetry model AVIDOS based on FLUKA-2005 simulations for routine dose assessment. The code has been developed by Austrian Research Centers (ARC) for the public usage (http://avidos.healthphysics.at).

  4. Biological dose estimation for charged-particle therapy using an improved PHITS code coupled with a microdosimetric kinetic model.

    PubMed

    Sato, Tatsuhiko; Kase, Yuki; Watanabe, Ritsuko; Niita, Koji; Sihver, Lembit

    2009-01-01

    Microdosimetric quantities such as lineal energy, y, are better indexes for expressing the RBE of HZE particles in comparison to LET. However, the use of microdosimetric quantities in computational dosimetry is severely limited because of the difficulty in calculating their probability densities in macroscopic matter. We therefore improved the particle transport simulation code PHITS, providing it with the capability of estimating the microdosimetric probability densities in a macroscopic framework by incorporating a mathematical function that can instantaneously calculate the probability densities around the trajectory of HZE particles with a precision equivalent to that of a microscopic track-structure simulation. A new method for estimating biological dose, the product of physical dose and RBE, from charged-particle therapy was established using the improved PHITS coupled with a microdosimetric kinetic model. The accuracy of the biological dose estimated by this method was tested by comparing the calculated physical doses and RBE values with the corresponding data measured in a slab phantom irradiated with several kinds of HZE particles. The simulation technique established in this study will help to optimize the treatment planning of charged-particle therapy, thereby maximizing the therapeutic effect on tumors while minimizing unintended harmful effects on surrounding normal tissues.

  5. [IMPLEMENTATION OF THE RIGHT FOR HEALTH CARE FOR CHILDREN - INTERNALLY DISPLACED PERSONS (CERTAIN ASPECTS)].

    PubMed

    Buletsa, S; Lazur, Y; Mendzhul, M; Pushkarenko, О

    2017-12-01

    The aim of the article is to do a research on selected issues related to realizing the right for health сare for the children - internally dislocated persons. In order to achieve the given aim statistical data of the quantity of involuntarily dislocated persons including children and also the quantity of children registered with the health-care authority as well as the quantity of their requests for medical care have been analized. It has been determined that in case of involuntary dislocation children are more often exposed to trauma than adults which leads to different emotional disorders. The concepts of «the right for health care» in international legal acts, national legislation of Ukraine and scientific works have been analized. There have been defined three levels of the provision of the right for health care of internally dislocated persons. It has been substantiated that the fact that a child has not been registered with the health-care authority as IRP can't be a ground for limitations in realization of his right on health care. During the research process it has been defined that children IRP need medical care more often than other internally dislocated persons and in realization of the right for health care they come across a number of problems that need urgent solution, including access to free of charge professional medical care, regardless of the fact of medical registration of a child IRP, insufficient funding for provision of the needs of children IRP with medications, absence of obligatory primary medical examination of children IRP, etc.

  6. SITE SPECIFIC REFERENCE PERSON PARAMETERS AND DERIVED CONCENTRATION STANDARDS FOR THE SAVANNAH RIVER SITE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jannik, T.

    2013-03-14

    The purpose of this report is twofold. The first is to develop a set of behavioral parameters for a reference person specific for the Savannah River Site (SRS) such that the parameters can be used to determine dose to members of the public in compliance with Department of Energy (DOE) Order 458.1 “Radiation Protection of the Public and the Environment.” A reference person is a hypothetical, gender and age aggregation of human physical and physiological characteristics arrived at by international consensus for the purpose of standardizing radiation dose calculations. DOE O 458.1 states that compliance with the annual dose limitmore » of 100 mrem (1 mSv) to a member of the public may be demonstrated by calculating the dose to the maximally exposed individual (MEI) or to a representative person. Historically, for dose compliance, SRS has used the MEI concept, which uses adult dose coefficients and adult male usage parameters. Beginning with the 2012 annual site environmental report, SRS will be using the representative person concept for dose compliance. The dose to a representative person will be based on 1) the SRS-specific reference person usage parameters at the 95th percentile of appropriate national or regional data, which are documented in this report, 2) the reference person (gender and age averaged) ingestion and inhalation dose coefficients provided in DOE Derived Concentration Technical Standard (DOE-STD-1196-2011), and 3) the external dose coefficients provided in the DC_PAK3 toolbox. The second purpose of this report is to develop SRS-specific derived concentration standards (DCSs) for all applicable food ingestion pathways, ground shine, and water submersion. The DCS is the concentration of a particular radionuclide in water, in air, or on the ground that results in a member of the public receiving 100 mrem (1 mSv) effective dose following continuous exposure for one year. In DOE-STD-1196-2011, DCSs were developed for the ingestion of water, inhalation of air and submersion in air pathways, only. These DCSs are required by DOE O 458.1 to be used at all DOE sites in the design and conduct of radiological environmental protection programs. In this report, DCSs for the following additional pathways were considered and documented: ingestion of meat, dairy, grains, produce (fruits and vegetables), seafood, submersion in water and ground shine. These additional DCSs were developed using the same methods as in DOE-STD-1196-2011 and will be used at SRS, where appropriate, as screening and reference values.« less

  7. Population dose commitments due to radioactive releases from nuclear power plant sites in 1983

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.; Peloquin, R.A.

    Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1983. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 52 sites. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ. Also included for each of the sites is a histogram showing the fraction of the total population within 2 to 80 km aroundmore » each site receiving various average dose commitments from the airborne pathways. The total dose commitments (from both liquid and airborne pathways) for each site ranged from a high of 45 person-rem to a low of 0.002 person-rem for the sites with plants operating throughout the year with an arithmetic mean of 3 person-rem. The total population dose for all sites was estimated at 170 person-rem for the 100 million people considered at risk.« less

  8. 27 CFR 41.261 - Records.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... person placing the order with the importer (for example, the importer is not an independent contractor but the agent of the person placing the order). Records maintained must reflect the date and quantity... picking up the processed tobacco for delivery; (3) The license number of the vehicle in which the...

  9. 27 CFR 41.261 - Records.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... person placing the order with the importer (for example, the importer is not an independent contractor but the agent of the person placing the order). Records maintained must reflect the date and quantity... picking up the processed tobacco for delivery; (3) The license number of the vehicle in which the...

  10. Skin dosimetry of patients during interventional cardiology procedures in the Czech Republic

    NASA Astrophysics Data System (ADS)

    Sukupova, Lucie; Novak, Leos

    2008-01-01

    The aim of the study is to determine distribution of air kerma-area product, fluoro time and number of frames values for the two most frequent procedures in the interventional cardiology, to reconstruct skin dose distributions for some patients undergoing coronarography and percutaneous transluminal coronary angioplasty procedures. Patient dose data were obtained from X-ray unit dose monitoring software report from one hospital and the reconstructions were performed in MATLAB. Dependence of maximum skin dose on air kerma-area product, fluoro time and number of frames was determined to assess trigger levels of these quantities, which can indicate possible exceeding of the 2 Gy skin dose threshold.

  11. EVALUATION OF EYE LENS DOSES OF INTERVENTIONAL CARDIOLOGISTS.

    PubMed

    Yokoyama, Sumi; Suzuki, Shoichi; Toyama, Hiroshi; Arakawa, Shinji; Inoue, Satoshi; Kinomura, Yutaka; Kobayashi, Ikuo

    2017-04-01

    The effective dose of medical staff members, especially interventional radiologists and cardiologists, is classified as a relatively high level. We measured the dose for interventional cardiologists by using optically stimulated luminescence dosimeters (OSLDs). However, this quantity is not the same as Hp (3). In experiments, the dose at the eye-lens position of a phantom were measured using OSLDs and thermoluminescence dosimeters (TLDs). A conversion factor from dose measured by using TLDs to OSLDs was estimated from these results. In addition, the eye doses of interventional cardiologists in clinical situations were measured, and the effect of eyewear on the eye-lens dose was discussed. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Population dose commitments due to radioactive releases from nuclear-power-plant sites in 1978

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peloquin, R.A.; Schwab, J.D.; Baker, D.A.

    Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1978. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each site. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ. Also included for each site is a histogram showing the fraction of the total population within 2 to 80 km around each site receiving variousmore » average dose commitments from the airborne pathways. The total dose commitment from both liquid and airborne pathways ranged from a high of 200 person-rem to a low of 0.0004 person-rem with an arithmetic mean of 14 person-rem. The total population dose for allsites was estimated at 660 person-rem for the 93 million people considered at risk. The average individual dose commitment from all pathways on a site basis ranged from a low of 3 x 10/sup -6/ mrem to a high of 0.08 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites.« less

  13. Population dose commitments due to radioactive releases from Nuclear-Power-Plant Sites in 1979

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.; Peloquin, R.A.

    Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1979. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each site. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ. Also included for each site is a histogram showing the fraction of the total population within 2 to 80 km around each site receiving variousmore » average dose commitments from the airborne pathways. The total dose commitment from both liquid and airborne pathways ranged from a high of 1300 person-rem to a low of 0.0002 person-rem with an arithmetic mean of 38 person-rem. The total population dose for all sites was estimated at 1800 person-rem for the 94 million people considered at risk. The average individual dose commitment from all pathways on a site basis ranged from a low of 2 x 10/sup -6/ mrem to a high of 0.7 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites.« less

  14. Population Dose Commitments Due to Radioactive Releases from Nuclear Power Plant Sites in 1977

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D. A.

    Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1977. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each site. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ, Also included for each site is a histogram showing the fraction of the total population within 2 to 80 km around each site receiving variousmore » average dose commitments from the airborne pathways. The total dose commitment from both liquid and airborne pathways ranged from a high of 220 person-rem to a low of 0.003 person-rem with an arithmetic mean of 16 person-rem. The total population dose for all sites was estimated at 700 person-rem for the 92 million people considered at risk. The average individual dose commitment from all pathways on a site basis ranged from a low of 2 x 10{sup -5} mrem to a high of 0.1 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites.« less

  15. Physics from the News--Fukushima Daiichi: Radiation Doses and Dose Rates

    ERIC Educational Resources Information Center

    Bartlett, A. A.

    2011-01-01

    The nuclear disaster that was triggered by the Japanese earthquake and the following tsunami of March 11, 2011, continues to be the subject of a great deal of news coverage. The tsunami caused severe damage to the nuclear power reactors at Fukushima Daiichi, and this led to the escape of unknown quantities of radioactive material from the damaged…

  16. 241Am Ingrowth and Its Effect on Internal Dose

    DOE PAGES

    Konzen, Kevin

    2016-07-01

    Generally, plutonium has been manufactured to support commercial and military applications involving heat sources, weapons and reactor fuel. This work focuses on three typical plutonium mixtures, while observing the potential of 241Am ingrowth and its effect on internal dose. The term “ingrowth” is used to describe 241Am production due solely from the decay of 241Pu as part of a plutonium mixture, where it is initially absent or present in a smaller quantity. Dose calculation models do not account for 241Am ingrowth unless the 241Pu quantity is specified. This work suggested that 241Am ingrowth be considered in bioassay analysis when theremore » is a potential of a 10% increase to the individual’s committed effective dose. It was determined that plutonium fuel mixtures, initially absent of 241Am, would likely exceed 10% for typical reactor grade fuel aged less than 30 years; however, heat source grade and aged weapons grade fuel would normally fall below this threshold. In conclusion, although this work addresses typical plutonium mixtures following separation, it may be extended to irradiated commercial uranium fuel and is expected to be a concern in the recycling of spent fuel.« less

  17. On effective dose for radiotherapy based on doses to nontarget organs and tissues

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uselmann, Adam J., E-mail: ajuselmann@wisc.edu; Thomadsen, Bruce R.

    2015-02-15

    Purpose: The National Council for Radiation Protection and Measurement (NCRP) published estimates for the collective population dose and the mean effective dose to the population of the United States from medical imaging procedures for 1980/1982 and for 2006. The earlier report ignored the effective dose from radiotherapy and the latter gave a cursory discussion of the topic but again did not include it in the population exposure for various reasons. This paper explains the methodology used to calculate the effective dose in due to radiotherapy procedures in the latter NCRP report and revises the values based on more detailed modeling.more » Methods: This study calculated the dose to nontarget organs from radiotherapy for reference populations using CT images and published peripheral dose data. Results: Using International Commission on Radiological Protection (ICRP) 60 weighting factors, the total effective dose to nontarget organs in radiotherapy patients is estimated as 298 ± 194 mSv per patient, while the U.S. population effective dose is 0.939 ± 0.610 mSv per person, with a collective dose of 283 000 ± 184 000 person Sv per year. Using ICRP 103 weighting factors, the effective dose is 281 ± 183 mSv per patient, 0.887 ± 0.577 mSv per person in the U.S., and 268 000 ± 174 000 person Sv per year. The uncertainty in the calculations is largely governed by variations in patient size, which was accounted for by considering a range of patient sizes and taking the average treatment site to nontarget organ distance. Conclusions: The methods used to estimate the effective doses from radiotherapy used in NCRP Report No. 160 have been explained and the values updated.« less

  18. 7 CFR 906.41 - Gift fruit shipments.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Gift fruit shipments. 906.41 Section 906.41... LOWER RIO GRANDE VALLEY IN TEXAS Order Regulating Handling Regulation § 906.41 Gift fruit shipments. The handling to any person of gift packages of fruit individually addressed to such person, in quantities...

  19. The Insulation Board Industry - An Economic Analysis

    Treesearch

    Albert T. Schuler

    1978-01-01

    An econometric model of the domestic insulation board industry was developed to identify and quantify the major factors affecting quantity consumed and price. The factors identified were housing starts, residential improvement activity, disposable personal income, productivity, pulpwood and residue prices, and power costs. Disposable personal income was the most...

  20. Effect of pelleting on survival of porcine epidemic diarrhea virus-contaminated feed.

    PubMed

    Cochrane, R A; Schumacher, L L; Dritz, S S; Woodworth, J C; Huss, A R; Stark, C R; DeRouchey, J M; Tokach, M D; Goodband, R D; Bia, J; Chen, Q; Zhang, J; Gauger, P C; Derscheid, R J; Magstadt, D R; Main, R G; Jones, C K

    2017-03-01

    Porcine epidemic diarrhea virus (PEDV) is a heat-sensitive virus that has devastated the U.S. swine industry. Because of its heat sensitivity, we hypothesized that a steam conditioner and pellet mill mimicking traditional commercial thermal processing may mitigate PEDV infectivity. Pelleting, a common feed processing method, includes the use of steam and shear forces, resulting in increased temperature of the processed feed. Two thermal processing experiments were designed to determine if different pellet mill conditioner retention times and temperatures would impact PEDV quantity and infectivity by analysis of quantitative reverse transcription PCR and bioassay. In Exp. 1, a 3 × 3 × 2 factorial design was used with 3 pelleting temperatures (68.3, 79.4, and 90.6°C), 3 conditioning times (45, 90, or 180 s), and 2 doses of viral inoculation (low, 1 × 10 tissue culture infectious dose (the concentration used to see cytopathic effect in 50% of the cells)/g, or high, 1 × 10 tissue culture infectious dose/g). Noninoculated and PEDV-inoculated unprocessed mash were used as controls. The low-dose PEDV-infected mash had 6.8 ± 1.8 cycle threshold (Ct) greater ( < 0.05) PEDV than the high-dose mash. Regardless of time or temperature, pelleting reduced ( < 0.05) the quantity of detectable viral PEDV RNA compared with the PEDV-inoculated unprocessed mash. Fecal swabs from pigs inoculated with the PEDV-positive unprocessed mash, regardless of dose, were clinically PEDV positive from 2 to 7 d (end of the trial) after inoculation. However, if either PEDV dose of inoculated feed was pelleted at any of the 9 tested conditioning time × temperature combinations, no PEDV RNA was detected in fecal swabs or cecum content. Based on Exp. 1 results, a second experiment was developed to determine the impact of lower processing temperatures on PEDV quantity and infectivity. In Exp. 2, PEDV-inoculated feed was pelleted at 1 of 5 conditioning temperatures (37.8, 46.1, 54.4, 62.8, and 71.1°C) for 30 s. The 5 increasing processing temperatures led to feed with respective mean Ct values of 32.5, 34.6, 37.0, 36.5, and 36.7, respectively. All samples had detectable PEDV RNA. However, infectivity was detected by bioassay only in pigs from the 37.8 and 46.1°C conditioning temperatures. Experiment 2 results suggest conditioning and pelleting temperatures above 54.4°C could be effective in reducing the quantity and infectivity of PEDV in swine feed. However, additional research is needed to prevent subsequent recontamination after pelleting as it is a point-in-time mitigation step.

  1. Eye lens dose correlations with personal dose equivalent and patient exposure in paediatric interventional cardiology performed with a fluoroscopic biplane system.

    PubMed

    Alejo, L; Koren, C; Corredoira, E; Sánchez, F; Bayón, J; Serrada, A; Guibelalde, E

    2017-04-01

    To analyse the correlations between the eye lens dose estimates performed with dosimeters placed next to the eyes of paediatric interventional cardiologists working with a biplane system, the personal dose equivalent measured on the thorax and the patient dose. The eye lens dose was estimated in terms of H p (0.07) on a monthly basis, placing optically stimulated luminescence dosimeters (OSLDs) on goggles. The H p (0.07) personal dose equivalent was measured over aprons with whole-body OSLDs. Data on patient dose as recorded by the kerma-area product (P KA ) were collected using an automatic dose management system. The 2 paediatric cardiologists working in the facility were involved in the study, and 222 interventions in a 1-year period were evaluated. The ceiling-suspended screen was often disregarded during interventions. The annual eye lens doses estimated on goggles were 4.13±0.93 and 4.98±1.28mSv. Over the aprons, the doses obtained were 10.83±0.99 and 11.97±1.44mSv. The correlation between the goggles and the apron dose was R 2 =0.89, with a ratio of 0.38. The correlation with the patient dose was R 2 =0.40, with a ratio of 1.79μSvGy -1 cm -2 . The dose per procedure obtained over the aprons was 102±16μSv, and on goggles 40±9μSv. The eye lens dose normalized to P KA was 2.21±0.58μSvGy -1 cm -2 . Measurements of personal dose equivalent over the paediatric cardiologist's apron are useful to estimate eye lens dose levels if no radiation protection devices are typically used. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  2. Alcohol-related negative consequences among drinkers around the world.

    PubMed

    Graham, Kathryn; Bernards, Sharon; Knibbe, Ronald; Kairouz, Sylvia; Kuntsche, Sandra; Wilsnack, Sharon C; Greenfield, Thomas K; Dietze, Paul; Obot, Isidore; Gmel, Gerhard

    2011-08-01

    This paper examines (i) gender and country differences in negative consequences related to drinking; (ii) relative rates of different consequences; and (iii) country-level predictors of consequences. Multi-level analyses used survey data from the Gender, Alcohol, and Culture: An International Study (GENACIS) collaboration. Measures included 17 negative consequences grouped into (i) high endorsement acute, (ii) personal and (iii) social. Country-level measures included average frequency and quantity of drinking, percentage who were current drinkers, gross domestic product (GDP) and Human Development Index (HDI). Overall, the three groupings of consequences were reported by 44%, 12% and 7% of men and by 31%, 6% and 3% of women, respectively. More men than women endorsed all consequences, but gender differences were greatest for consequences associated with chronic drinking and social consequences related to male roles. The highest prevalence of consequences was in Uganda and lowest in Uruguay. Personal and social consequences were more likely in countries with higher usual quantity, fewer current drinkers and lower scores on GDP and HDI. However, significant interactions with individual-level quantity indicated a stronger relationship between consequences and usual quantity among drinkers in countries with lower quantity, more current drinkers and higher scores on GDP and HDI. Both gender and country need to be taken into consideration when assessing adverse drinking consequences. Individual measures of alcohol consumption and country-level variables are associated with experiencing such consequences. Additionally, country-level variables affect the strength of the relationship between usual quantity consumed by individuals and adverse consequences. © 2011 The Authors, Addiction © 2011 Society for the Study of Addiction.

  3. Magneto-acupuncture stimuli effects on ultraweak photon emission from hands of healthy persons.

    PubMed

    Park, Sang-Hyun; Kim, Jungdae; Koo, Tae-Hoi

    2009-03-01

    We investigated ultraweak photon emissions from the hands of 45 healthy persons before and after magneto-acupuncture stimuli. Photon emissions were measured by using two photomultiplier tubes in the spectral range of UV and visible. Several statistical quantities such as the average intensity, the standard deviation, the delta-value, and the degree of asymmetry were calculated from the measurements of photon emissions before and after the magneto-acupuncture stimuli. The distributions of the quantities from the measurements with the magneto-acupuncture stimuli were more differentiable than those of the groups without any stimuli and with the sham magnets. We also analyzed the magneto-acupuncture stimuli effects on the photon emissions through a year-long measurement for two subjects. The individualities of the subjects increased the differences of photon emissions compared to the above group study before and after magnetic stimuli. The changes on the ultraweak photon emission rates of hand for the magnet group were detected conclusively in the quantities of the averages and standard deviations.

  4. PK-guided personalized prophylaxis with Nuwiq® (human-cl rhFVIII) in adults with severe haemophilia A.

    PubMed

    Lissitchkov, T; Rusen, L; Georgiev, P; Windyga, J; Klamroth, R; Gercheva, L; Nemes, L; Tiede, A; Bichler, J; Knaub, S; Belyanskaya, L; Walter, O; Pasi, K J

    2017-09-01

    Nuwiq ® (human-cl rhFVIII) is a 4 th generation recombinant human FVIII, without chemical modification or protein fusion, produced in a human cell-line. This study (NuPreviq) was a prospective, open-label, multicentre, phase IIIb study of the efficacy and safety of personalized prophylaxis with Nuwiq ® in 66 previously treated adults with severe haemophilia A. NuPreviq had three phases: (i) a 72-h pharmacokinetic (PK) phase; (ii) a 1-3 month standard prophylaxis phase; and (iii) a 6-month personalized prophylaxis phase. The personalized prophylaxis regimen was based on individual PK modelling for each patient according to whether their PK profile most closely fitted a two- or one-compartment model (NuPreviq approach). In cases of uncertainty, a noncompartment model was applied. The median dosing interval during personalized prophylaxis was 3.5 days, with 57% of patients on ≤2 weekly dosing. Mean annualized bleeding rates during personalized prophylaxis were 1.45 (median [interquartile range, IQR]: 0 [0, 1.9]) for all bleeds, 0.79 (median [IQR]: 0 [0, 0]) for spontaneous bleeds, and 0.91 (median [IQR]: 0 [0, 0]) for joint bleeds. During personalized prophylaxis, 83.1% of patients were spontaneous bleed-free. Compared with standard prophylaxis, median weekly prophylaxis dose was reduced by 7.2% from 100.0 to 92.8 IU kg -1 during the last 2 months of personalized prophylaxis. There were no FVIII inhibitors or treatment-related serious or severe adverse events. PK-guided personalized prophylaxis with Nuwiq ® provided bleeding protection and enabled the dosing interval to be extended to twice weekly or less in many patients and an overall dose reduction. © 2017 The Authors. Haemophilia Published by John Wiley & Sons Ltd.

  5. The relationship between ambient ultraviolet radiation (UVR) and objectively measured personal UVR exposure dose is modified by season and latitude.

    PubMed

    Sun, J; Lucas, R M; Harrison, S; van der Mei, I; Armstrong, B K; Nowak, M; Brodie, A; Kimlin, M G

    2014-12-01

    Despite the widespread use of ambient ultraviolet radiation (UVR) as a proxy measure of personal exposure to UVR, the relationship between the two is not well-defined. This paper examines the effects of season and latitude on the relationship between ambient UVR and personal UVR exposure. We used data from the AusD Study, a multi-centre cross-sectional study among Australian adults (18-75 years), where personal UVR exposure was objectively measured using polysulphone dosimeters. Data were analysed for 991 participants from 4 Australian cities of different latitude: Townsville (19.3°S), Brisbane (27.5°S), Canberra (35.3°S) and Hobart (42.8°S). Daily personal UVR exposure varied from 0.01 to 21 Standard Erythemal Doses (median = 1.1, IQR: 0.5-2.1), on average accounting for 5% of the total available ambient dose. There was an overall positive correlation between ambient UVR and personal UVR exposure (r = 0.23, p < 0.001). However, the correlations varied according to season and study location: from strong correlations in winter (r = 0.50) and at high latitudes (Hobart, r = 0.50; Canberra, r = 0.39), to null or even slightly negative correlations, in summer (r = 0.01) and at low latitudes (Townsville, r = -0.06; Brisbane, r = -0.16). Multiple regression models showed significant effect modification by season and location. Personal exposure fraction of total available ambient dose was highest in winter (7%) and amongst Hobart participants (7%) and lowest in summer (1%) and in Townsville (4%). These results suggest season and latitude modify the relationship between ambient UVR and personal UVR exposure. Ambient UVR may not be a good indicator for personal exposure dose under some circumstances.

  6. [Effects of Betel shisanwei ingredients pill on AC-cAMP-PKA signal transduction pathways in hippocampus and prefrontal cortex of depressive rats].

    PubMed

    Tong, Hai-Ying; Wu, Jisiguleng; Bai, Liang-Feng; Bao, Wu-Ye; Hu, Rilebagen; Li, Jing; Zhang, Yue

    2014-05-01

    To observe the effects of Mongolian pharmaceutical Betel shisanwei ingredients pill on AC-cAMP-PKA signal transduction pathways in hippocampus and prefrontal cortex of depressive rats. Sixty male Wistar rats were randomly divided into six groups according to the sugar consumption test (10 rats in each group), normal control group,model group,fluoxetine group (3.3 mg x kg(-1)) and low dose, medium dose and high dose group (0.25, 0.5, 1 g x kg(-1)) of Betel shisanwei ingredients pill. Except the normal control,the other groups were treated with the chronic unpredictable mild stress stimulation combined with lonely raising for 28 days. 10 mL x kg(-1) of drugs were given to each rat once daily,continuously for 28 days. The AC activity of the hippocampus and prefrontal cortex were determined by radiation immunity analysis (RIA), while cAMP and PKA quantity were determinated by Enzyme-linked immunosorbent (ELISA). The AC activity, cAMP and PKA quantity of hippocampus and prefrontal of mouse model of Chronic stress depression decreased significantly than those of control group (P < 0.05 or P < 0.01). However, the AC activity, cAMP and PKA quantity of rat hippocampus and prefrontal cortex in the fluoxetine group and the Mongolian pharmaceutical Betel shisanwei ingredients pill group indecreased significantly than those of model group (P < 0.01 or P < 0.05). Especially for the high dose group of Mongolian pharmaceutical Betel shisanwei ingredients pill. The AC-cAMP-PKA signal transduction pathways in hippocampus and prefrontal cortex of depression model of rats is down-regulated, whereas Mongolian pharmaceutical Betel shisanwei ingredients pill could up-regulated it to resist depression.

  7. Personalized versus standardized dosing strategies for the treatment of childhood amblyopia: study protocol for a randomized controlled trial.

    PubMed

    Moseley, Merrick J; Wallace, Michael P; Stephens, David A; Fielder, Alistair R; Smith, Laura C; Stewart, Catherine E

    2015-04-25

    Amblyopia is the commonest visual disorder of childhood in Western societies, affecting, predominantly, spatial visual function. Treatment typically requires a period of refractive correction ('optical treatment') followed by occlusion: covering the nonamblyopic eye with a fabric patch for varying daily durations. Recent studies have provided insight into the optimal amount of patching ('dose'), leading to the adoption of standardized dosing strategies, which, though an advance on previous ad-hoc regimens, take little account of individual patient characteristics. This trial compares the effectiveness of a standardized dosing strategy (that is, a fixed daily occlusion dose based on disease severity) with a personalized dosing strategy (derived from known treatment dose-response functions), in which an initially prescribed occlusion dose is modulated, in a systematic manner, dependent on treatment compliance. A total of 120 children aged between 3 and 8 years of age diagnosed with amblyopia in association with either anisometropia or strabismus, or both, will be randomized to receive either a standardized or a personalized occlusion dose regimen. To avoid confounding by the known benefits of refractive correction, participants will not be randomized until they have completed an optical treatment phase. The primary study objective is to determine whether, at trial endpoint, participants receiving a personalized dosing strategy require fewer hours of occlusion than those in receipt of a standardized dosing strategy. Secondary objectives are to quantify the relationship between observed changes in visual acuity (logMAR, logarithm of the Minimum Angle of Resolution) with age, amblyopia type, and severity of amblyopic visual acuity deficit. This is the first randomized controlled trial of occlusion therapy for amblyopia to compare a treatment arm representative of current best practice with an arm representative of an entirely novel treatment regimen based on statistical modelling of previous trial outcome data. Should the personalized dosing strategy demonstrate superiority over the standardized dosing strategy, then its adoption into routine practice could bring practical benefits in reducing the duration of treatment needed to achieve an optimal outcome. ISRCTN ISRCTN12292232.

  8. The Many Faces of Affect: A Multilevel Model of Drinking Frequency/Quantity and Alcohol Dependence Symptoms Among Young Adults

    PubMed Central

    Simons, Jeffrey S.; Wills, Thomas A.; Neal, Dan J.

    2016-01-01

    This research tested a multilevel structural equation model of associations between 3 aspects of affective functioning (state affect, trait affect, and affective lability) and 3 alcohol outcomes (likelihood of drinking, quantity on drinking days, and dependence symptoms) in a sample of 263 college students. Participants provided 49 days of experience sampling data over 1.3 years in a longitudinal burst design. Within-person results: At the daily level, positive affect was directly associated with greater likelihood and quantity of alcohol consumption. Daily negative affect was directly associated with higher consumption on drinking days and with higher dependence symptoms. Between-person direct effects: Affect lability was associated with higher trait negative, but not positive, affect. Trait positive affect was inversely associated with the proportion of drinking days, whereas negative affectivity predicted a greater proportion of drinking days. Affect lability exhibited a direct association with dependence symptoms. Between-person indirect effects: Trait positive affect was associated with fewer dependence symptoms via proportion of drinking days. Trait negative affect was associated with greater dependence symptoms via proportion of drinking days. The results distinguish relations of positive and negative affect to likelihood versus amount of drinking and state versus trait drinking outcomes, and highlight the importance of affect variability for predicting alcohol dependence symptoms. PMID:24933278

  9. Binge Alcohol Use among Persons Aged 12 to 20: 2002 and 2003 Update. The NSDUH Report

    ERIC Educational Resources Information Center

    Substance Abuse and Mental Health Services Administration, 2005

    2005-01-01

    Research has shown that persons who engage in binge alcohol use as teenagers are at increased risk for binge drinking as young adults. Binge Alcohol Use among Persons Aged 12 to 20: 2002 and 2003 Update asks respondents aged 12 or older to report their frequency and quantity of alcohol use during the month before the survey. NSDUH defines binge…

  10. Population dose commitments due to radioactive releases from nuclear power plant sites in 1985

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.

    Population radiation dose commitments have been estimated from reported radionuclide releases from commericial power reactors operating during 1985. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 61 sites. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ. Also included for each of the sites is a histogram showing the fraction of the total population within 2 to 80 km aroundmore » each site receiving various average dose commitments from the airborne pathways. The total dose commitments (from both liquid and airborne pathways) for each site ranged from a high of 73 person-rem to a low of 0.011 person-rem for the sites with plants operating throughout the year with an arithmetic mean of 3 person-rem. The total population dose for all sites was estimated at 200 person-rem for the 110 million people considered at risk. The site average individual dose commitment from all pathways ranged from a low of 5 /times/ 10/sup /minus/6/ mrem to a high of 0.02 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites.« less

  11. Population dose commitments due to radioactive releases from nuclear power plant sites in 1984

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.

    Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1984. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 56 sites. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ. Also included for each of the sites is a histogram showing the fraction of the total population within 2 to 80 km aroundmore » each site receiving various average dose commitments from the airborne pathways. The total dose commitments (from both liquid and airborne pathways) for each site ranged from a high of 110 person-rem to a low of 0.002 person-rem for the sites with plants operating throughout the year with an arithmetic mean of 5 person-rem. The total population dose for all sites was estimated at 280 person-rem for the 100 million people considered at risk. The site average individual dose commitment from all pathways ranged from a low of 6 x 10/sup -6/ mrem to a high of 0.04 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites.« less

  12. Population dose commitments due to radioactive releases from nuclear power plant sites in 1986

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.

    Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1986. Fifty-year dose commitments for a one-year exposure from both liquid and atmospheric releases were calculated for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 66 reactor sites. This report tabulates the results of these calculations, showing the dose commitments for both water and airborne pathways for each age group and organ. Also included for each of the sites is a histogram showing the fraction of the total population within 2 to 80 kmmore » around each site receiving various average dose commitments from the airborne pathways. The total dose commitments (from both liquid and airborne pathways) for each site ranged from a high of 31 person-rem to a low of 0.0007 person-rem for the sites with plants operating throughout the year with an arithmetic mean of 1.7 person-rem. The total population dose for all sites was estimated at 110 person-rem for the 140 million people considered at risk. The site average individual dose commitment from all pathways ranged from a low of 2 {times} 10{sup -6} mrem to a high of 0.02 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites. 12 refs.« less

  13. Population dose commitments due to radioactive releases from nuclear power plant sites in 1982. Volume 4

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.; Peloquin, R.A.

    Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1982. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 51 sites. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ. Also included for each site is a histogram showing the fraction of the total population within 2 to 80 km around each sitemore » receiving various average dose commitments from the airborne pathways. The total dose commitments from both liquid and airborne pathways ranged from a high of 30 person-rem to a low of 0.007 person-rem for the sites with plants operating throughout the year with an arithmetic mean of 3 person-rem. The total population dose for all sites was estimated at 130 person-rem for the 100 million people considered at risk. The average individual dose commitment from all pathways on a site basis ranged from a low of 6 x 10/sup -7/ mrem to a high of 0.06 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites.« less

  14. Coercive and Prosocial Fathering, Antisocial Personality, and Growth in Children's Postdivorce Noncompliance

    ERIC Educational Resources Information Center

    DeGarmo, David Scott

    2010-01-01

    To better understand quantity and quality of divorced father contact, a weighted county sample of 230 divorced fathers with a child aged 4-11 years was employed to test whether fathers' antisocial personality (ASP) moderated effects of monthly contact with children in predicting children's observed noncompliance. Eighteen-month latent growth…

  15. 41 CFR 102-36.450 - Do we report excess shelf-life items?

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... shelf-life items? 102-36.450 Section 102-36.450 Public Contracts and Property Management Federal...-DISPOSITION OF EXCESS PERSONAL PROPERTY Personal Property Whose Disposal Requires Special Handling Shelf-Life Items § 102-36.450 Do we report excess shelf-life items? (a) When there are quantities on hand, that...

  16. 7 CFR 1434.15 - Personal liability..

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... REGULATIONS FOR HONEY § 1434.15 Personal liability.. (a) When applying for an individual or joint loan or loan deficiency payment, each producer agrees: (1) When signing Form CCC-633 (Honey), Honey Loan Certification and...) Unauthorized removal of honey, which shall include, but is not limited to, the movement of any loan quantity of...

  17. Radiation Protection Quantities for Near Earth Environments

    NASA Technical Reports Server (NTRS)

    Clowdsley, Martha S.; Wilson, John W.; Kim, Myung-Hee; Anderson, Brooke M.; Nealy, John E.

    2004-01-01

    As humans travel beyond the protection of the Earth's magnetic field and mission durations grow, risk due to radiation exposure will increase and may become the limiting factor for such missions. Here, the dosimetric quantities recommended by the National Council on Radiation Protection and Measurements (NCRP) for the evaluation of health risk due to radiation exposure, effective dose and gray-equivalent to eyes, skin, and blood forming organs (BFO), are calculated for several near Earth environments. These radiation protection quantities are evaluated behind two different shielding materials, aluminum and polyethylene. Since exposure limits for missions beyond low Earth orbit (LEO) have not yet been defined, results are compared to limits recommended by the NCRP for LEO operations.

  18. SU-F-T-669: Commissioning of An Electronic Brachytherapy System for Targeted Mouse Irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Culberson, W; Micka, J; Carchman, E

    Purpose: The aim of this study was to commission the Xoft Axxent™ electronic brachytherapy (eBT) source and 10 mm diameter surface applicator with NIST traceability for targeted irradiations of mouse anal carcinomas. Methods: The Xoft Axxent™ electronic brachytherapy (eBT) and 10 mm diameter surface applicator was chosen by the collaborating physician as a radiation delivery mechanism for mouse anal carcinomas. The target dose was 2 Gy at a depth of 3 mm in tissue to be delivered in a single fraction. To implement an accurate and reliable irradiation plan, the system was commissioned by first determining the eBT source outputmore » and corresponding dose rate at a depth of 3 mm in tissue. This was determined through parallel-plate ion chamber measurements and published conversion factors. Well-type ionization chamber measurements were used to determine a transfer coefficient, which correlates the measured dose rate at 3 mm to the NIST-traceable quantity, air-kerma rate at 50 cm in air, for eBT sources. By correlating these two quantities, daily monitoring in the well chamber becomes an accurate and efficient quality assurance technique. Once the dose-rate was determined, a treatment recipe was developed and confirmed with chamber measurements to deliver the requested dose. Radiochromic film was used to verify the dose distribution across the field. Results: Dose rates at 3 mm depth in tissue were determined for two different Xoft Axxent™ sources and correlated with NIST-traceable well-type ionization chamber measurements. Unique transfer coefficients were determined for each source and the treatment recipe was validated by measurements. Film profiles showed a uniform dose distribution across the field. Conclusion: A Xoft Axxent™ eBT system was successfully commissioned for use in the irradiation of mouse rectal tumors. Dose rates in tissue were determined as well as other pertinent parameters to ensure accurate delivery of dose to the target region.« less

  19. Dose reduction and cost-benefit analysis at Japan`s Tokai No. 2 Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Humamoto, Hisao; Suzuki, Seishiro; Taniguchi, Kazufumi

    1995-03-01

    In the Tokai No. 2 power plant of the Japan Atomic Power Company, about 80% of the annual dose equivalent is received during periodic maintenance outages. A project group for dose reduction was organized at the company`s headquarters in 1986; in 1988, they proposed a five-year program to reduce by half the collective dose of 4 person-Sv per normal outage work. To achieve the target dose value, some dose-reduction measures were undertaken, namely, permanent radiation shielding, decontamination, automatic, operating machines, and ALARA organization. As the result, the collective dose from normal outage work was 1.6 person-Sv in 1992, which wasmore » less than the initial target value.« less

  20. Influence of therapist competence and quantity of cognitive behavioural therapy on suicidal behaviour and inpatient hospitalisation in a randomised controlled trial in borderline personality disorder: Further analyses of treatment effects in the BOSCOT study

    PubMed Central

    Norrie, John; Davidson, Kate; Tata, Philip; Gumley, Andrew

    2013-01-01

    Objectives We investigated the treatment effects reported from a high-quality randomized controlled trial of cognitive behavioural therapy (CBT) for 106 people with borderline personality disorder attending community-based clinics in the UK National Health Service – the BOSCOT trial. Specifically, we examined whether the amount of therapy and therapist competence had an impact on our primary outcome, the number of suicidal acts†, using instrumental variables regression modelling. Design Randomized controlled trial. Participants from across three sites (London, Glasgow, and Ayrshire/Arran) were randomized equally to CBT for personality disorders (CBTpd) plus Treatment as Usual or to Treatment as Usual. Treatment as Usual varied between sites and individuals, but was consistent with routine treatment in the UK National Health Service at the time. CBTpd comprised an average 16 sessions (range 0–35) over 12 months. Method We used instrumental variable regression modelling to estimate the impact of quantity and quality of therapy received (recording activities and behaviours that took place after randomization) on number of suicidal acts and inpatient psychiatric hospitalization. Results A total of 101 participants provided full outcome data at 2 years post randomization. The previously reported intention-to-treat (ITT) results showed on average a reduction of 0.91 (95% confidence interval 0.15–1.67) suicidal acts over 2 years for those randomized to CBT. By incorporating the influence of quantity of therapy and therapist competence, we show that this estimate of the effect of CBTpd could be approximately two to three times greater for those receiving the right amount of therapy from a competent therapist. Conclusions Trials should routinely control for and collect data on both quantity of therapy and therapist competence, which can be used, via instrumental variable regression modelling, to estimate treatment effects for optimal delivery of therapy. Such estimates complement rather than replace the ITT results, which are properly the principal analysis results from such trials. Practitioner points Assessing the impact of the quantity and quality of therapy (competence of therapists) is complex. More competent therapists, trained in CBTpd, may significantly reduce the number of suicidal act in patients with borderline personality disorder. PMID:23420622

  1. Macroscopic singlet oxygen modeling for dosimetry of Photofrin-mediated photodynamic therapy: an in-vivo study

    NASA Astrophysics Data System (ADS)

    Qiu, Haixia; Kim, Michele M.; Penjweini, Rozhin; Zhu, Timothy C.

    2016-08-01

    Although photodynamic therapy (PDT) is an established modality for cancer treatment, current dosimetric quantities, such as light fluence and PDT dose, do not account for the differences in PDT oxygen consumption for different fluence rates (φ). A macroscopic model was adopted to evaluate using calculated reacted singlet oxygen concentration ([) to predict Photofrin-PDT outcome in mice bearing radiation-induced fibrosarcoma tumors, as singlet oxygen is the primary cytotoxic species responsible for cell death in type II PDT. Using a combination of fluences (50, 135, 200, and 250 J/cm2) and φ (50, 75, and 150 mW/cm2), tumor regrowth rate, k, was determined for each condition. A tumor cure index, CI=1-k/k, was calculated based on the k between PDT-treated groups and that of the control, k. The measured Photofrin concentration and light dose for each mouse were used to calculate PDT dose and [, while mean optical properties (μa=0.9 cm-1, μs‧=8.4 cm-1) were used to calculate φ for all mice. CI was correlated to the fluence, PDT dose, and [ with R2=0.35, 0.79, and 0.93, respectively. These results suggest that [ serves as a better dosimetric quantity for predicting PDT outcome.

  2. Development of Probiotic Formulation for the Treatment of Iron Deficiency Anemia.

    PubMed

    Korčok, Davor Jovan; Tršić-Milanović, Nada Aleksandar; Ivanović, Nevena Djuro; Đorđević, Brižita Ivan

    2018-04-01

    Probiotics are increasingly more present both as functional foods, and in pharmaceutical preparations with multiple levels of action that contribute to human health. Probiotics realize their positive effects with a proper dose, and by maintaining a declared number of probiotics cells by the expiration date. Important precondition for developing a probiotic product is the right choice of clinically proven probiotic strain, the choice of other active components, as well as, the optimization of the quantity of active component of probiotic per product dose. This scientific paper describes the optimization of the number of probiotics cells in the formulation of dietary supplement that contains probiotic culture Lactobacillus plantarum 299v, iron and vitamin C. Variations of the quantity of active component were analyzed in development batches of the encapsulated probiotic product categorized as dietary supplement with the following ingredients: probiotic culture, sucrosomal form of iron and vitamin C. Optimal quantity of active component L. plantarum of 50 mg, was selected. The purpose of this scientific paper is to select the optimal formulation of probiotic culture in a dietary supplement that contains iron and vitamin C, and to also determine its expiration date by the analysis of the number of viable probiotic cells.

  3. Tissue sulfomucin and sialomucin content in colon mucosa without intestinal transit subjected to intervention with Curcuma longa (curcumin).

    PubMed

    Alves, Antonio José Tiburcio; Pereira, José Aires; Pansani, Adrieli Heloísa Campardo; Magro, Daniela Oliveira; Coy, Cláudio Saddy Rodrigues; Martinez, Carlos Augusto Real

    2017-03-01

    To measure the tissue sulfomucin and sialomucin content of the colon mucosa without fecal flow, subjected to intervention with curcumin, and the influence of the concentration used and the intervention time. Thirty-six rats were subjected to proximal right colostomy and distal mucous fistula. They were divided into two groups according to whether sacrifice was performed two or four weeks after the intervention. Each group was divided into three subgroups according to the enema applied daily: saline alone; curcumin at 50 mg/kg/day or curcumin at 200 mg/kg/day. Acid mucins were diagnosed using the Alcian blue technique. The mucin content was quantified by means of computer-assisted image analysis. The significance level of 5% was used throughout (p < 0.05). There were dose-related increases in the quantities of sulfomucins in the animals subjected to interventions with curcumin, both after two weeks (p < 0.00001) and after four weeks (p < 0.00001). There were increases in sialomucin quantity that were concentration-related (p < 0.00001) and time-related (p < 0.00001). Curcumin enemas increase the quantity of acid mucins in the intestinal flow in the excluded colon, with dose and time dependency.

  4. Effect of Embolization Material in the Calculation of Dose Deposition in Arteriovenous Malformations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    De la Cruz, O. O. Galvan; Moreno-Jimenez, S.; Larraga-Gutierrez, J. M.

    2010-12-07

    In this work it is studied the impact of the incorporation of high Z materials (embolization material) in the dose calculation for stereotactic radiosurgery treatment for arteriovenous malformations. A statistical analysis is done to establish the variables that may impact in the dose calculation. To perform the comparison pencil beam (PB) and Monte Carlo (MC) calculation algorithms were used. The comparison between both dose calculations shows that PB overestimates the dose deposited. The statistical analysis, for the quantity of patients of the study (20), shows that the variable that may impact in the dose calculation is the volume of themore » high Z material in the arteriovenous malformation. Further studies have to be done to establish the clinical impact with the radiosurgery result.« less

  5. Population dose commitments due to radioactive releases from nuclear power plant sites in 1988

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.

    Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1988. Fifty-year commitments for a one-year exposure from both liquid and atmospheric releases were calculated for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 71 reactor sites. This report tabulates the results of these calculations, showing the dose commitments for both water and airborne pathways for each age group and organ. Also included for each of the sites is a histogram showing the fraction of the total population within 2 to 80 km aroundmore » each site receiving various average dose commitments from the airborne pathways. The total collective dose commitments (from both liquid and airborne pathways) for each site ranged from a high of 16 person-rem to a low of 0.0011 person-rem for the sites with plants operating throughout the year with an arithmetic mean of 1.1 person-rem. The total population dose for all sites was estimated at 75 person-rem for the 150 million people considered at risk. The site average individual dose commitment from all pathways ranged from a low of 3 {times} 10{sup {minus}7} mrem to a high of 0.02 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites. However, licensee calculation of doses to the maximally exposed individual at some sites indicated values of up to approximately 100 times average individual doses (on the order of a few millirem per year).« less

  6. Population dose commitments due to radioactive releases from nuclear power plant sites in 1988. Volume 10

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.

    Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1988. Fifty-year commitments for a one-year exposure from both liquid and atmospheric releases were calculated for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 71 reactor sites. This report tabulates the results of these calculations, showing the dose commitments for both water and airborne pathways for each age group and organ. Also included for each of the sites is a histogram showing the fraction of the total population within 2 to 80 km aroundmore » each site receiving various average dose commitments from the airborne pathways. The total collective dose commitments (from both liquid and airborne pathways) for each site ranged from a high of 16 person-rem to a low of 0.0011 person-rem for the sites with plants operating throughout the year with an arithmetic mean of 1.1 person-rem. The total population dose for all sites was estimated at 75 person-rem for the 150 million people considered at risk. The site average individual dose commitment from all pathways ranged from a low of 3 {times} 10{sup {minus}7} mrem to a high of 0.02 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites. However, licensee calculation of doses to the maximally exposed individual at some sites indicated values of up to approximately 100 times average individual doses (on the order of a few millirem per year).« less

  7. Regulating approaches to learning: Testing learning strategy convergences across a year at university.

    PubMed

    Fryer, Luke K; Vermunt, Jan D

    2018-03-01

    Contemporary models of student learning within higher education are often inclusive of processing and regulation strategies. Considerable research has examined their use over time and their (person-centred) convergence. The longitudinal stability/variability of learning strategy use, however, is poorly understood, but essential to supporting student learning across university experiences. Develop and test a person-centred longitudinal model of learning strategies across the first-year university experience. Japanese university students (n = 933) completed surveys (deep and surface approaches to learning; self, external, and lack of regulation) at the beginning and end of their first year. Following invariance and cross-sectional tests, latent profile transition analysis (LPTA) was undertaken. Initial difference testing supported small but significant differences for self-/external regulation. Fit indices supported a four-group model, consistent across both measurement points. These subgroups were labelled Low Quality (low deep approaches and self-regulation), Low Quantity (low strategy use generally), Average (moderate strategy use), and High Quantity (intense use of all strategies) strategies. The stability of these groups ranged from stable to variable: Average (93% stayers), Low Quality (90% stayers), High Quantity (72% stayers), and Low Quantity (40% stayers). The three largest transitions presented joint shifts in processing/regulation strategy preference across the year, from adaptive to maladaptive and vice versa. Person-centred longitudinal findings presented patterns of learning transitions that different students experience during their first year at university. Stability/variability of students' strategy use was linked to the nature of initial subgroup membership. Findings also indicated strong connections between processing and regulation strategy changes across first-year university experiences. Implications for theory and practice are discussed. © 2017 The British Psychological Society.

  8. Role of alcohol drinking pattern in type 2 diabetes in Japanese men: the Toranomon Hospital Health Management Center Study 11 (TOPICS 11).

    PubMed

    Heianza, Yoriko; Arase, Yasuji; Saito, Kazumi; Tsuji, Hiroshi; Fujihara, Kazuya; Hsieh, Shiun Dong; Kodama, Satoru; Shimano, Hitoshi; Yamada, Nobuhiro; Hara, Shigeko; Sone, Hirohito

    2013-03-01

    Findings of past studies on the effect of drinking patterns on diabetes risk have been inconsistent. We aimed to investigate the role of drinking frequency and usual quantity consumed in the development of type 2 diabetes. Enrolled were 1650 Japanese men without diabetes (diabetes: fasting plasma glucose ≥7.0 mmol/L, glycated hemoglobin ≥6.5%, or self-reported clinician-diagnosed diabetes). Average alcohol consumption and 12 combinations of frequency and usual quantity per drinking occasion were assessed at the baseline examination. The absolute risk and HR for the development of diabetes were calculated. During a mean follow-up period of 10.2 y, 216 individuals developed diabetes. Lifetime abstainers (n = 153) had a relatively low incidence of diabetes (9.1/1000 person-years), similar to moderate consumers (99-160 g ethanol/wk; 9.0/1000 person-years). Increasingly higher quantities of alcohol usually consumed per occasion increased the risk of diabetes regardless of drinking frequency. The lowest incidence rate of diabetes (8.5/1000 person-years) was associated with the consumption of <1 drink (<23 g ethanol) per occasion over ≥6 times/wk. Binge drinking (≥3 drinks per occasion) significantly increased the risk of future diabetes regardless of frequency (HR: 1.79; 95% CI: 1.17, 2.74) compared with <1 drink per occasion. Among current drinkers, a drinking pattern of <1 drink per occasion regularly over 6 times within a week was associated with the lowest risk of developing diabetes. Usual quantity per drinking occasion was a more important determinant than was weekly drinking frequency in the association between alcohol consumption and risk of diabetes in Japanese men.

  9. Unraveling the Importance of the Quantity and the Quality of Workers' Motivation for Well-Being: A Person-Centered Perspective

    ERIC Educational Resources Information Center

    Van den Broeck, Anja; Lens, Willy; De Witte, Hans; Van Coillie, Hermina

    2013-01-01

    The current study compares the quantitative and the qualitative viewpoints on work motivation by relying on Self-Determination Theory's differentiation between autonomous and controlled motivation. Specifically, we employed a person-centered approach to identify workers' naturally occurring motivational profiles and compared them in terms of…

  10. PCP METHODOLOGY FOR DETERMINING DOSE RATES FOR SMALL GRAM QUANTITIES IN SHIPPING PACKAGINGS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nathan, S.

    The Small Gram Quantity (SGQ) concept is based on the understanding that small amounts of hazardous materials, in this case radioactive materials, are significantly less hazardous than large amounts of the same materials. This study describes a methodology designed to estimate an SGQ for several neutron and gamma emitting isotopes that can be shipped in a package compliant with 10 CFR Part 71 external radiation level limits regulations. These regulations require packaging for the shipment of radioactive materials perform, under both normal and accident conditions, the essential functions of material containment, subcriticality, and maintain external radiation levels within regulatory limits.more » 10 CFR 71.33(b)(1)(2)&(3) state radioactive and fissile materials must be identified and their maximum quantity, chemical and physical forms be included in an application. Furthermore, the U.S. Federal Regulations require application contain an evaluation demonstrating the package (i.e., the packaging and its contents) satisfies the external radiation standards for all packages (10 CFR 71.31(2), 71.35(a), & 71.47). By placing the contents in a He leak-tight containment vessel, and limiting the mass to ensure subcriticality, the first two essential functions are readily met. Some isotopes emit sufficiently strong photon radiation that small amounts of material can yield a large external dose rate. Quantifying of the dose rate for a proposed content is a challenging issue for the SGQ approach. It is essential to quantify external radiation levels from several common gamma and neutron sources that can be safely placed in a specific packaging, to ensure compliance with federal regulations. The Packaging Certification Program (PCP) Methodology for Determining Dose Rate for Small Gram Quantities in Shipping Packagings described in this report provides bounding mass limits for a set of proposed SGQ isotopes. Methodology calculations were performed to estimate external radiation levels for the 9977 shipping package using the MCNP radiation transport code to develop a set of response multipliers (Green's functions) for 'dose per particle' for each neutron and photon spectral group. The source spectrum for each isotope generated using the ORIGEN-S and RASTA computer codes was folded with the response multipliers to generate the dose rate per gram of each isotope in the 9977 shipping package and its associated shielded containers. The maximum amount of a single isotope that could be shipped within the regulatory limits contained in 10 CFR 71.47 for dose rate at the surface of the package is determined. If a package contains a mixture of isotopes, the acceptability for shipment can be determined by a sum of fractions approach. Furthermore, the results of this analysis can be easily extended to additional radioisotopes by simply evaluating the neutron and/or photon spectra of those isotopes and folding the spectral data with the Green's functions provided.« less

  11. A Web-Based System for Bayesian Benchmark Dose Estimation.

    PubMed

    Shao, Kan; Shapiro, Andrew J

    2018-01-11

    Benchmark dose (BMD) modeling is an important step in human health risk assessment and is used as the default approach to identify the point of departure for risk assessment. A probabilistic framework for dose-response assessment has been proposed and advocated by various institutions and organizations; therefore, a reliable tool is needed to provide distributional estimates for BMD and other important quantities in dose-response assessment. We developed an online system for Bayesian BMD (BBMD) estimation and compared results from this software with U.S. Environmental Protection Agency's (EPA's) Benchmark Dose Software (BMDS). The system is built on a Bayesian framework featuring the application of Markov chain Monte Carlo (MCMC) sampling for model parameter estimation and BMD calculation, which makes the BBMD system fundamentally different from the currently prevailing BMD software packages. In addition to estimating the traditional BMDs for dichotomous and continuous data, the developed system is also capable of computing model-averaged BMD estimates. A total of 518 dichotomous and 108 continuous data sets extracted from the U.S. EPA's Integrated Risk Information System (IRIS) database (and similar databases) were used as testing data to compare the estimates from the BBMD and BMDS programs. The results suggest that the BBMD system may outperform the BMDS program in a number of aspects, including fewer failed BMD and BMDL calculations and estimates. The BBMD system is a useful alternative tool for estimating BMD with additional functionalities for BMD analysis based on most recent research. Most importantly, the BBMD has the potential to incorporate prior information to make dose-response modeling more reliable and can provide distributional estimates for important quantities in dose-response assessment, which greatly facilitates the current trend for probabilistic risk assessment. https://doi.org/10.1289/EHP1289.

  12. Establishing bounding internal dose estimates for thorium activities at Rocky Flats.

    PubMed

    Ulsh, Brant A; Rich, Bryce L; Chew, Melton H; Morris, Robert L; Sharfi, Mutty; Rolfes, Mark R

    2008-07-01

    As part of an evaluation of a Special Exposure Cohort petition filed on behalf of workers at the Rocky Flats Plant, the National Institute for Occupational Safety and Health (NIOSH) was required to demonstrate that bounding values could be established for radiation doses due to the potential intake of all radionuclides present at the facility. The main radioactive elements of interest at Rocky Flats were plutonium and uranium, but much smaller quantities of several other elements, including thorium, were occasionally handled at the site. Bounding potential doses from thorium has proven challenging at other sites due to the early historical difficulty in detecting this element through urinalysis methods and the relatively high internal dose delivered per unit intake. This paper reports the results of NIOSH's investigation of the uses of thorium at Rocky Flats and provides bounding dose reconstructions for these operations. During this investigation, NIOSH reviewed unclassified reports, unclassified extracts of classified materials, material balance and inventory ledgers, monthly progress reports from various groups, and health physics field logbooks, and conducted interviews with former Rocky Flats workers. Thorium operations included: (1) an experimental metal forming project with 240 kg of thorium in 1960; (2) the use of pre-formed parts in weapons mockups; (3) the removal of Th from U; (4) numerous analytical procedures involving trace quantities of thorium; and (5) the possible experimental use of thorium as a mold coating compound. The thorium handling operations at Rocky Flats were limited in scope, well-monitored and documented, and potential doses can be bounded.

  13. Health effects from fallout.

    PubMed

    Gilbert, Ethel S; Land, Charles E; Simon, Steven L

    2002-05-01

    This paper primarily discusses health effects that have resulted from exposures received as a result of above-ground nuclear tests, with emphasis on thyroid disease from exposure to 131I and leukemia and solid cancers from low dose rate external and internal exposure. Results of epidemiological studies of fallout exposures in the Marshall Islands and from the Nevada Test Site are summarized, and studies of persons with exposures similar to those from fallout are briefly reviewed (including patients exposed to 131I for medical reasons and workers exposed externally at low doses and low dose rates). Promising new studies of populations exposed in countries of the former Soviet Union are also discussed and include persons living near the Semipalatinsk Test Site in Kazakhstan, persons exposed as a result of the Chernobyl accident, and persons exposed as a result of operations of the Mayak Nuclear Plant in the Russian Federation. Very preliminary estimates of cancer risks from fallout doses received by the United States population are presented.

  14. Neutron dosimetric measurements in shuttle and MIR.

    PubMed

    Reitz, G

    2001-06-01

    Detector packages consisting of thermoluminescence detectors (TLD), nuclear emulsions and plastic track detectors were exposed at identical positions inside MIR space station and on shuttle flights inside Spacelab and Spacehab during different phases of the solar cycle. The objectives of the investigations are to provide data on charge and energy spectra of heavy ions, and the contribution of events with low-energy deposit (protons, electrons, gamma, etc.) to the dose, as well as the contribution of secondaries, such as nuclear disintegration stars and neutrons. For neutron dosimetry 6LiF (TLD600) and 7LiF (TLD700) chips were used both of which have almost the same response to gamma rays but different response to neutrons. Neutrons in space are produced mainly in evaporation and knock-on processes with energies mainly of 1-10 MeV and up to several 100 MeV, respectively. The energy spectrum undergoes continuous changes toward greater depth in the attenuating material until an equilibrium is reached. In equilibrium, the spectrum is a wide continuum extending down to thermal energies to which the 6LiF is sensitive. Based on the difference of absorbed doses in the 6LiF and 7LiF chips, thermal neutron fluxes from 1 to 2.3 cm-2 s-1 are calculated using the assumption that the maximum induced dose in TLD600 for 1 neutron cm-2 is 1.6 x 10(-10) Gy (Horowitz and Freeman, Nucl. Instr. and Meth. 157 (1978) 393). It is assumed that the flux of high-energy neutrons is at least of that quantity. Tissue doses were calculated taking as a mean ambient absorbed dose per neutron 6 x10(-12) Gy cm2 (for a10 MeV neutron). The neutron equivalent doses for the above-mentioned fluxes are 52 micro Gy d-1 and 120 micro Gy d-1. In recent experiments, a personal neutron dosimeter was integrated into the dosimeter packages. First results of this dosimeter which is based on nuclear track detectors with converter foils are reported. For future measurements, a scintillator counter with anticoincidence logic is under development. c2001 Elsevier Science Ltd. All rights reserved.

  15. Current status of radiological protection at nuclear power stations in Japan.

    PubMed

    Suzuki, Akira; Hori, Shunsuke

    2011-07-01

    The radiation dose to workers at nuclear power stations (NPSs) in Japan was drastically reduced between the late-1970s and the early-1990s by continuous dose-reduction programmes. The total collective dose of radiation workers in FY 2008 was 84.04 person Sv, while the average collective dose was 1.5 person Sv per reactor. The average annual individual dose was 1.1 mSv and the maximum annual individual dose was 19.5 mSv. These values are sufficiently lower than the regulatory dose limits. Radioactive effluent released from NPSs is already so trivial that additional protective measures will not be necessary. Experience in radiation protection at NPSs has been accumulated over 40 y and will be very useful in establishing a rational radiation control system in the future.

  16. Control installation for the proportioning of a secondary air quantity for improvement of the combustion in internal combustion engines or the afterburning of the exhaust gases of internal combustion engines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bockelmann, W.; Groezinger, H.; Woebky, P.U.

    1977-01-04

    A control installation is described for the dosing or proportioning of a secondary air quantity for the improvement of combustion in internal combustion engines, or the after-burning of the exhaust gases of internal combustion engines. An auxiliary arrangement is responsive to an emergency signal for effecting the prompt shutting-off of the secondary air. The emergency signal may be initiated in response to a failure in the ignition voltage of the internal combustion engine; an increase in the hydrocarbon content of the exhaust gases; a disparity between the position of the mixture dosing element and the engine rotational speed; the exceedingmore » of a limiting temperature in the exhaust gas manifold; or the exceeding of a limiting temperature in the afterburner.« less

  17. Organ and effective dose conversion coefficients for a sitting female hybrid computational phantom exposed to monoenergetic protons in idealized irradiation geometries.

    PubMed

    Alves, M C; Santos, W S; Lee, Choonsik; Bolch, Wesley E; Hunt, John G; Carvalho Júnior, A B

    2014-12-21

    The conversion coefficients (CCs) relate protection quantities, mean absorbed dose (DT) and effective dose (E), with physical radiation field quantities, such as fluence (Φ). The calculation of CCs through Monte Carlo simulations is useful for estimating the dose in individuals exposed to radiation. The aim of this work was the calculation of conversion coefficients for absorbed and effective doses per fluence (DT/ Φ and E/Φ) using a sitting and standing female hybrid phantom (UFH/NCI) exposure to monoenergetic protons with energy ranging from 2 MeV to 10 GeV. The radiation transport code MCNPX was used to develop exposure scenarios implementing the female UFH/NCI phantom in sitting and standing postures. Whole-body irradiations were performed using the recommended irradiation geometries by ICRP publication 116 (AP, PA, RLAT, LLAT, ROT and ISO). In most organs, the conversion coefficients DT/Φ were similar for both postures. However, relative differences were significant for organs located in the abdominal region, such as ovaries, uterus and urinary bladder, especially in the AP, RLAT and LLAT geometries. Anatomical differences caused by changing the posture of the female UFH/NCI phantom led an attenuation of incident protons with energies below 150 MeV by the thigh of the phantom in the sitting posture, for the front-to-back irradiation, and by the arms and hands of the phantom in the standing posture, for the lateral irradiation.

  18. Reduced lung-cancer mortality with low-dose computed tomographic screening.

    PubMed

    Aberle, Denise R; Adams, Amanda M; Berg, Christine D; Black, William C; Clapp, Jonathan D; Fagerstrom, Richard M; Gareen, Ilana F; Gatsonis, Constantine; Marcus, Pamela M; Sicks, JoRean D

    2011-08-04

    The aggressive and heterogeneous nature of lung cancer has thwarted efforts to reduce mortality from this cancer through the use of screening. The advent of low-dose helical computed tomography (CT) altered the landscape of lung-cancer screening, with studies indicating that low-dose CT detects many tumors at early stages. The National Lung Screening Trial (NLST) was conducted to determine whether screening with low-dose CT could reduce mortality from lung cancer. From August 2002 through April 2004, we enrolled 53,454 persons at high risk for lung cancer at 33 U.S. medical centers. Participants were randomly assigned to undergo three annual screenings with either low-dose CT (26,722 participants) or single-view posteroanterior chest radiography (26,732). Data were collected on cases of lung cancer and deaths from lung cancer that occurred through December 31, 2009. The rate of adherence to screening was more than 90%. The rate of positive screening tests was 24.2% with low-dose CT and 6.9% with radiography over all three rounds. A total of 96.4% of the positive screening results in the low-dose CT group and 94.5% in the radiography group were false positive results. The incidence of lung cancer was 645 cases per 100,000 person-years (1060 cancers) in the low-dose CT group, as compared with 572 cases per 100,000 person-years (941 cancers) in the radiography group (rate ratio, 1.13; 95% confidence interval [CI], 1.03 to 1.23). There were 247 deaths from lung cancer per 100,000 person-years in the low-dose CT group and 309 deaths per 100,000 person-years in the radiography group, representing a relative reduction in mortality from lung cancer with low-dose CT screening of 20.0% (95% CI, 6.8 to 26.7; P=0.004). The rate of death from any cause was reduced in the low-dose CT group, as compared with the radiography group, by 6.7% (95% CI, 1.2 to 13.6; P=0.02). Screening with the use of low-dose CT reduces mortality from lung cancer. (Funded by the National Cancer Institute; National Lung Screening Trial ClinicalTrials.gov number, NCT00047385.).

  19. Definition of Small Gram Quantity Contents for Type B Radioactive Material Transportation Packages: Activity-Based Content Limitations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sitaraman, S; Kim, S; Biswas, D

    2010-10-27

    Since the 1960's, the Department of Transportation Specification (DOT Spec) 6M packages have been used extensively for transportation of Type B quantities of radioactive materials between Department of Energy (DOE) facilities, laboratories, and productions sites. However, due to the advancement of packaging technology, the aging of the 6M packages, and variability in the quality of the packages, the DOT implemented a phased elimination of the 6M specification packages (and other DOT Spec packages) in favor of packages certified to meet federal performance requirements. DOT issued the final rule in the Federal Register on October 1, 2004 requiring that use ofmore » the DOT Specification 6M be discontinued as of October 1, 2008. A main driver for the change was the fact that the 6M specification packagings were not supported by a Safety Analysis Report for Packaging (SARP) that was compliant with Title 10 of the Code of Federal Regulations part 71 (10 CFR 71). Therefore, materials that would have historically been shipped in 6M packages are being identified as contents in Type B (and sometimes Type A fissile) package applications and addenda that are to be certified under the requirements of 10 CFR 71. The requirements in 10 CFR 71 include that the Safety Analysis Report for Packaging (SARP) must identify the maximum radioactivity of radioactive constituents and maximum quantities of fissile constituents (10 CFR 71.33(b)(1) and 10 CFR 71.33(b)(2)), and that the application (i.e., SARP submittal or SARP addendum) demonstrates that the external dose rate (due to the maximum radioactivity of radioactive constituents and maximum quantities of fissile constituents) on the surface of the packaging (i.e., package and contents) not exceed 200 mrem/hr (10 CFR 71.35(a), 10 CFR 71.47(a)). It has been proposed that a 'Small Gram Quantity' of radioactive material be defined, such that, when loaded in a transportation package, the dose rates at external points of an unshielded packaging not exceed the regulatory limits prescribed by 10 CFR 71 for non-exclusive shipments. The mass of each radioisotope presented in this paper is limited by the radiation dose rate on the external surface of the package, which per the regulatory limit should not exceed 200 mrem/hr. The results presented are a compendium of allowable masses of a variety of different isotopes (with varying impurity levels of beryllium in some of the actinide isotopes) that, when loaded in an unshielded packaging, do not result in an external dose rate on the surface of the package that exceeds 190 mrem/hr (190 mrem/hr was chosen to provide 5% conservatism relative to the regulatory limit). These mass limits define the term 'Small Gram Quantity' (SGQ) contents in the context of radioactive material transportation packages. The term SGQ is isotope-specific and pertains to contents in radioactive material transportation packages that do not require shielding and still satisfy the external dose rate requirements. Since these calculated mass limits are for contents without shielding, they are conservative for packaging materials that provide some limited shielding or if the contents are placed into a shielded package. The isotopes presented in this paper were chosen as the isotopes that Department of Energy (DOE) sites most likely need to ship. Other more rarely shipped isotopes, along with industrial and medical isotopes, are planned to be included in subsequent extensions of this work.« less

  20. Reducing Alcohol Use in First-Year University Students: Evaluation of a Web-Based Personalized Feedback Program

    ERIC Educational Resources Information Center

    Doumas, Diana M.; Andersen, Lorna L.

    2009-01-01

    The efficacy of a Web-based personalized feedback program--electronic CHECKUP TO GO (e-CHUG), aimed at reducing heavy drinking in 1st-year university students--is evaluated. Results indicated that high-risk students in the e-CHUG group reported significantly greater reductions in weekly drinking quantity, frequency of drinking to intoxication, and…

  1. [Prophylaxis of alcoholic disease of the liver].

    PubMed

    Beliakin, S A

    2009-08-01

    Military doctors should have a uniform position to the use of alcohol. Now alcohol is the basic pathogenic factor in development of a lethal cirrhosis of a liver. The most known sayings justifying the use of alcohol, are insolvent. Useful doses of alcohol does not exist. The quantity of used alcohol has the great value. Only at achievement of age 21 year it is possible to use safe doses of alcohol. A safe dose of pure alcohol (ethanol) less than 30,0 in day. In a basis of prophylaxis of a cirrhosis of a liver there is a medical educational activity.

  2. The ENEA neutron personal dosimetry service.

    PubMed

    Morelli, B; Mariotti, F; Fantuzzi, E

    2006-01-01

    The ENEA Radiation Protection Institute has been operating the only neutron personal dosimetry service in Italy since the 1970s. Since the 1980s the service has been based on PADC (poly allyl diglycol carbonate) for fast neutron dosimetry, while thermal neutron dosimetry has been performed using thermoluminescence (TL) dosemeters. Since the service was started, a number of aspects have undergone evolution. The latest and most important changes are as follows: in 1998 a new PADC material was introduced in routine, since 2001 TL thermal dosimetry has been based on LiF(Mg,Cu,P) [GR-200] and (7)LiF(Mg,Cu,P) [GR-207] detectors and since 2003 a new image analysis reading system for the fast neutron dosemeters has been used. Herein an updated summary of how the service operates and performs today is presented. The approaches to calibration and traceability to estimate the quantity of H(p)(10) are mentioned. Results obtained at the performance test of dosimetric services in the EU member states and Switzerland sponsored by the European Commission and organised by Eurados in 1999 are reported. Last but not least, quality assurance (QA) procedures introduced in the routine operation to track the whole process of dose evaluation (i.e. plastic QA, acceptance test, test etching bath reproducibility and 'dummy customer' (blind test) for each issuing monitoring period) are presented and discussed.

  3. Development of a tool for calculating early internal doses in the Fukushima Daiichi nuclear power plant accident based on atmospheric dispersion simulation

    NASA Astrophysics Data System (ADS)

    Kurihara, Osamu; Kim, Eunjoo; Kunishima, Naoaki; Tani, Kotaro; Ishikawa, Tetsuo; Furuyama, Kazuo; Hashimoto, Shozo; Akashi, Makoto

    2017-09-01

    A tool was developed to facilitate the calculation of the early internal doses to residents involved in the Fukushima Nuclear Disaster based on atmospheric transport and dispersion model (ATDM) simulations performed using Worldwide version of System for Prediction of Environmental Emergency Information 2nd version (WSPEEDI-II) together with personal behavior data containing the history of the whereabouts of individul's after the accident. The tool generates hourly-averaged air concentration data for the simulation grids nearest to an individual's whereabouts using WSPEEDI-II datasets for the subsequent calculation of internal doses due to inhalation. This paper presents an overview of the developed tool and provides tentative comparisons between direct measurement-based and ATDM-based results regarding the internal doses received by 421 persons from whom personal behavior data available.

  4. EPR TOOTH DOSIMETRY OF SNTS AREA INHABITANTS.

    PubMed

    Sholom, Sergey; Desrosiers, Marc; Bouville, André; Luckyanov, Nicholas; Chumak, Vadim; Simon, Steven L

    2007-07-01

    The determination of external dose to teeth of inhabitants of settlements near the Semipalatinsk Nuclear Test Site (SNTS) was conducted using the EPR dosimetry technique to assess radiation doses associated with exposure to radioactive fallout from the test site. In this study, tooth doses have been reconstructed for 103 persons with all studied teeth having been formed before the first nuclear test in 1949. Doses above those received from natural background radiation, termed "accident doses", were found to lie in the range from zero to approximately 2 Gy, with one exception, a dose for one person from Semipalatinsk city was approximately 9 Gy. The variability of reconstructed doses within each of the settlements demonstrated heterogeneity of the deposited fallout as well as variations in lifestyle. The village mean external gamma doses for residents of nine[ settlements were in the range from a few tens of mGy to approximately 100 mGy.

  5. Local infiltration of rabies immunoglobulins without systemic intramuscular administration: An alternative cost effective approach for passive immunization against rabies

    PubMed Central

    Bharti, Omesh Kumar; Madhusudana, Shampur Narayan; Gaunta, Pyare Lal; Belludi, Ashwin Yajaman

    2016-01-01

    ABSTRACT Presently the dose of rabies immunoglobulin (RIG) which is an integral part of rabies post exposure prophylaxis (PEP) is calculated based on body weight though the recommendation is to infiltrate the wound(s). This practice demands large quantities of RIG which may be unaffordable to many patients. In this background, we conducted this study to know if the quantity and cost of RIG can be reduced by restricting passive immunization to local infiltration alone and avoiding systemic intramuscular administration based on the available scientific evidence. Two hundred and sixty nine category III patients bitten by suspect or confirmed rabid dogs/animals were infiltrated with equine rabies immunoglobulin (ERIGs) in and around the wound. The quantity of ERIG used was proportionate to the size and number of wounds irrespective of their body weight. They were followed with a regular course of rabies vaccination by intra-dermal route. As against 363 vials of RIGs required for all these cases as per current recommendation based on body weight, they required only 42 vials of 5ml RIG. Minimum dose of RIGs given was 0.25 ml and maximum dose given was 8 ml. On an average 1.26 ml of RIGs was required per patient that costs Rs. 150 ($3). All the patients were followed for 9 months and they were healthy and normal at the end of observation period. With local infiltration, that required small quantities of RIG, the RIGs could be made available to all patients in times of short supply in the market. A total of 30 (11%) serum samples of patients were tested for rabies virus neutralizing antibodies by the rapid fluorescent focus inhibition test (RFFIT) and all showed antibody titers >0.5 IU/mL by day 14. In no case the dose was higher than that required based on body weight and no immunosuppression resulted. To conclude, this pilot study shows that local infiltration of RIG need to be considered in times of non-availability in the market or unaffordability by poor patients. This preliminary study needs to be done on larger scale in other centers with long term follow up to substantiate the results of our study. PMID:26317441

  6. Radiation exposure assessment for portsmouth naval shipyard health studies.

    PubMed

    Daniels, R D; Taulbee, T D; Chen, P

    2004-01-01

    Occupational radiation exposures of 13,475 civilian nuclear shipyard workers were investigated as part of a retrospective mortality study. Estimates of annual, cumulative and collective doses were tabulated for future dose-response analysis. Record sets were assembled and amended through range checks, examination of distributions and inspection. Methods were developed to adjust for administrative overestimates and dose from previous employment. Uncertainties from doses below the recording threshold were estimated. Low-dose protracted radiation exposures from submarine overhaul and repair predominated. Cumulative doses are best approximated by a hybrid log-normal distribution with arithmetic mean and median values of 20.59 and 3.24 mSv, respectively. The distribution is highly skewed with more than half the workers having cumulative doses <10 mSv and >95% having doses <100 mSv. The maximum cumulative dose is estimated at 649.39 mSv from 15 person-years of exposure. The collective dose was 277.42 person-Sv with 96.8% attributed to employment at Portsmouth Naval Shipyard.

  7. Pharyngeal and cervical cancer incidences significantly correlate with personal UV doses among whites in the United States.

    PubMed

    Godar, Dianne E; Tang, Rong; Merrill, Stephen J

    2014-09-01

    Because we found UV-exposed oral tissue cells have reduced DNA repair and apoptotic cell death compared with skin tissue cells, we asked if a correlation existed between personal UV dose and the incidences of oral and pharyngeal cancer in the United States. We analyzed the International Agency for Research on Cancer's incidence data for oral and pharyngeal cancers by race (white and black) and sex using each state's average annual personal UV dose. We refer to our data as 'white' rather than 'Caucasian,' which is a specific subgroup of whites, and 'black' rather than African-American because blacks from other countries around the world reside in the U.S. Most oropharyngeal carcinomas harboured human papilloma virus (HPV), so we included cervical cancer as a control for direct UV activation. We found significant correlations between increasing UV dose and pharyngeal cancer in white males (p=0.000808) and females (p=0.0031) but not in blacks. Shockingly, we also found cervical cancer in whites to significantly correlate with increasing UV dose (p=0.0154). Thus, because pharyngeal and cervical cancer correlate significantly with increasing personal UV dose in only the white population, both direct (DNA damage) and indirect (soluble factors) effects may increase the risk of HPV-associated cancer. Copyright© 2014 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  8. Messen, Kalibrieren, Eichen in der Radiologie: Prinzipien und Praxis

    NASA Astrophysics Data System (ADS)

    Wagner, Siegfried R.

    Nach einleitender Erläuterung der unterschiedlichen Meßbedingungen in der Strahlentherapie und im Strahlenschutz werden die metrologischen Probleme am Beispiel der Größenkategorie Äquivalentdosis diskutiert. Als spezielle Größen werden effektive Äquivalentdosis und Umgebungs-Äquivalentdosis eingeführt. Es wird gezeigt, wie richtiges Messen durch ein konsistentes System von Bauartanforderungen an Meßgeräte, durch Kalibrieren und durch Eichen gewährleistet werden kann. Die Bedeutung von Meßunsicherheiten und Fehlergrenzen wird erläutert und ihre Auswirkung auf die Interpretation von Meßergebnissen behandelt.Translated AbstractMeasurements, Calibration, Verification in Radiology: Principles and PracticeThe different measuring conditions in radiotherapy and in radiation protection are discussed in the introduction. Then, the metrological problems are discussed exemplarily with the dose equivalent as a category of quantity. Effective dose equivalent and ambient dose equivalent are introduced as special quantities. It is demonstrated, how correct measurements can be secured by a consistent system of instrument pattern requirements, by calibration and verification. The importance of uncertainties of measurements and of error limits is illustrated and their influence on the interpretation of the results of measurements is treated.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Konzen, Kevin

    Generally, plutonium has been manufactured to support commercial and military applications involving heat sources, weapons and reactor fuel. This work focuses on three typical plutonium mixtures, while observing the potential of 241Am ingrowth and its effect on internal dose. The term “ingrowth” is used to describe 241Am production due solely from the decay of 241Pu as part of a plutonium mixture, where it is initially absent or present in a smaller quantity. Dose calculation models do not account for 241Am ingrowth unless the 241Pu quantity is specified. This work suggested that 241Am ingrowth be considered in bioassay analysis when theremore » is a potential of a 10% increase to the individual’s committed effective dose. It was determined that plutonium fuel mixtures, initially absent of 241Am, would likely exceed 10% for typical reactor grade fuel aged less than 30 years; however, heat source grade and aged weapons grade fuel would normally fall below this threshold. In conclusion, although this work addresses typical plutonium mixtures following separation, it may be extended to irradiated commercial uranium fuel and is expected to be a concern in the recycling of spent fuel.« less

  10. Radiation effects on bovine taste bud membranes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shatzman, A.R.; Mossman, K.L.

    1982-11-01

    In order to investigate the mechanisms of radiation-induced taste loss, the effects of radiation on preparations of enriched bovine taste bud membranes were studied. Taste buds containing circumvallate papilae, and surrounding control epithelial tissues devoid of taste buds, were obtained from steers and given radiation doses of 0-7000 cGy (rad). Tissue fractions were isolated into membrane-enriched and heterogeneous components using differential and sucrose gradient centrifugation of tissue homogenates. The yield of membranes, as measured by protein content in the buoyant membrane-enriched fractions, was reduced in quantity with increasing radiation dose. The relation between radiation dose and membrane quantity in membrane-enrichedmore » fractions could be fit by a simple exponential model with taste bud-derived membranes twice as radiosensitive as membranes from control epithelial tissue. Binding of sucrose, sodium, and acetate and fluoride stimulation of adenylate cyclase were nearly identical in both irradiated and nonirradiated intact membranes. Radiation had no effect on fractions of heterogeneous components. While it is not clear what changes are occurring in enriched taste cell membranes, damage to membranes may play an important role in the taste loss observed in patients following radiotherapy.« less

  11. Minimizing Astronauts' Risk from Space Radiation during Future Lunar Missions

    NASA Technical Reports Server (NTRS)

    Kim, Myung-Hee Y.; Hayat, Mathew; Nounu, Hatem N.; Feiveson, Alan H.; Cucinotta, Francis A.

    2007-01-01

    This viewgraph presentation reviews the risk factors from space radiation for astronauts on future lunar missions. Two types of radiation are discussed, Galactic Cosmic Radiation (GCR) and Solar Particle events (SPE). Distributions of Dose from 1972 SPE at 4 DLOCs inside Spacecraft are shown. A chart with the organ dose quantities is also given. Designs of the exploration class spacecraft and the planned lunar rover are shown to exhibit radiation protections features of those vehicles.

  12. Monte Carlo dosimetric characterization of the Flexisource Co-60 high-dose-rate brachytherapy source using PENELOPE.

    PubMed

    Almansa, Julio F; Guerrero, Rafael; Torres, Javier; Lallena, Antonio M

    60 Co sources have been commercialized as an alternative to 192 Ir sources for high-dose-rate (HDR) brachytherapy. One of them is the Flexisource Co-60 HDR source manufactured by Elekta. The only available dosimetric characterization of this source is that of Vijande et al. [J Contemp Brachytherapy 2012; 4:34-44], whose results were not included in the AAPM/ESTRO consensus document. In that work, the dosimetric quantities were calculated as averages of the results obtained with the Geant4 and PENELOPE Monte Carlo (MC) codes, though for other sources, significant differences have been quoted between the values obtained with these two codes. The aim of this work is to perform the dosimetric characterization of the Flexisource Co-60 HDR source using PENELOPE. The MC simulation code PENELOPE (v. 2014) has been used. Following the recommendations of the AAPM/ESTRO report, the radial dose function, the anisotropy function, the air-kerma strength, the dose rate constant, and the absorbed dose rate in water have been calculated. The results we have obtained exceed those of Vijande et al. In particular, the absorbed dose rate constant is ∼0.85% larger. A similar difference is also found in the other dosimetric quantities. The effect of the electrons emitted in the decay of 60 Co, usually neglected in this kind of simulations, is significant up to the distances of 0.25 cm from the source. The systematic and significant differences we have found between PENELOPE results and the average values found by Vijande et al. point out that the dosimetric characterizations carried out with the various MC codes should be provided independently. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  13. Aircraft Crew Radiation Exposure in Aviation Altitudes During Quiet and Solar Storm Periods

    NASA Astrophysics Data System (ADS)

    Beck, Peter

    The European Commission Directorate General Transport and Energy published in 2004 a summary report of research on aircrew dosimetry carried out by the EURADOS working group WG5 (European Radiation Dosimetry Group, http://www.eurados.org/). The aim of the EURADOS working group WG5 was to bring together, in particular from European research groups, the available, preferably published, experimental data and results of calculations, together with detailed descriptions of the methods of measurement and calculation. The purpose is to provide a dataset for all European Union Member States for the assessment of individual doses and/or to assess the validity of different approaches, and to provide an input to technical recommendations by the experts and the European Commission. Furthermore EURADOS (European Radiation Dosimetry Group, http://www.eurados.org/) started to coordinate research activities in model improvements for dose assessment of solar particle events. Preliminary results related to the European research project CONRAD (Coordinated Network for Radiation Dosimetry) on complex mixed radiation fields at workplaces are presented. The major aim of this work is the validation of models for dose assessment of solar particle events, using data from neutron ground level monitors, in-flight measurement results obtained during a solar particle event and proton satellite data. The radiation protection quantity of interest is effective dose, E (ISO), but the comparison of measurement results obtained by different methods or groups, and comparison of measurement results and the results of calculations, is done in terms of the operational quantity ambient dose equivalent, H* (10). This paper gives an overview of aircrew radiation exposure measurements during quiet and solar storm conditions and focuses on dose results using the EURADOS In-Flight Radiation Data Base and published data on solar particle events

  14. Innovations in Medication Preparation Safety and Wastage Reduction: Use of a Workflow Management System in a Pediatric Hospital.

    PubMed

    Davis, Stephen Jerome; Hurtado, Josephine; Nguyen, Rosemary; Huynh, Tran; Lindon, Ivan; Hudnall, Cedric; Bork, Sara

    2017-01-01

    Background: USP <797> regulatory requirements have mandated that pharmacies improve aseptic techniques and cleanliness of the medication preparation areas. In addition, the Institute for Safe Medication Practices (ISMP) recommends that technology and automation be used as much as possible for preparing and verifying compounded sterile products. Objective: To determine the benefits associated with the implementation of the workflow management system, such as reducing medication preparation and delivery errors, reducing quantity and frequency of medication errors, avoiding costs, and enhancing the organization's decision to move toward positive patient identification (PPID). Methods: At Texas Children's Hospital, data were collected and analyzed from January 2014 through August 2014 in the pharmacy areas in which the workflow management system would be implemented. Data were excluded for September 2014 during the workflow management system oral liquid implementation phase. Data were collected and analyzed from October 2014 through June 2015 to determine whether the implementation of the workflow management system reduced the quantity and frequency of reported medication errors. Data collected and analyzed during the study period included the quantity of doses prepared, number of incorrect medication scans, number of doses discontinued from the workflow management system queue, and the number of doses rejected. Data were collected and analyzed to identify patterns of incorrect medication scans, to determine reasons for rejected medication doses, and to determine the reduction in wasted medications. Results: During the 17-month study period, the pharmacy department dispensed 1,506,220 oral liquid and injectable medication doses. From October 2014 through June 2015, the pharmacy department dispensed 826,220 medication doses that were prepared and checked via the workflow management system. Of those 826,220 medication doses, there were 16 reported incorrect volume errors. The error rate after the implementation of the workflow management system averaged 8.4%, which was a 1.6% reduction. After the implementation of the workflow management system, the average number of reported oral liquid medication and injectable medication errors decreased to 0.4 and 0.2 times per week, respectively. Conclusion: The organization was able to achieve its purpose and goal of improving the provision of quality pharmacy care through optimal medication use and safety by reducing medication preparation errors. Error rates decreased and the workflow processes were streamlined, which has led to seamless operations within the pharmacy department. There has been significant cost avoidance and waste reduction and enhanced interdepartmental satisfaction due to the reduction of reported medication errors.

  15. A new treatment planning formalism for catheter-based beta sources used in intravascular brachytherapy.

    PubMed

    Patel, N S; Chiu-Tsao, S T; Tsao, H S; Harrison, L B

    2001-01-01

    Intravascular brachytherapy (IVBT) is an emerging modality for the treatment of atherosclerotic lesions in the artery. As part of the refinement in this rapidly evolving modality of treatment, the current simplistic dosimetry approach based on a fixed-point prescription must be challenged by future rigorous dosimetry method employing image-based three-dimensional (3D) treatment planning. The goals of 3D IVBT treatment planning calculations include (1) achieving high accuracy in a slim cylindrical region of interest, (2) accounting for the edge effect around the source ends, and (3) supporting multiple dwell positions. The formalism recommended by Task Group 60 (TG-60) of the American Association of Physicists in Medicine (AAPM) is applicable for gamma sources, as well as short beta sources with lengths less than twice the beta particle range. However, for the elongated beta sources and/or seed trains with lengths greater than twice the beta range, a new formalism is required to handle their distinctly different dose characteristics. Specifically, these characteristics consist of (a) flat isodose curves in the central region, (b) steep dose gradient at the source ends, and (c) exponential dose fall-off in the radial direction. In this paper, we present a novel formalism that evolved from TG-60 in maintaining the dose rate as a product of four key quantities. We propose to employ cylindrical coordinates (R, Z, phi), which are more natural and suitable to the slim cylindrical shape of the volume of interest, as opposed to the spherical coordinate system (r, theta, phi) used in the TG-60 formalism. The four quantities used in this formalism include (1) the distribution factor, H(R, Z), (2) the modulation function, M(R, Z), (3) the transverse dose function, h(R), and (4) the reference dose rate at 2 mm along the perpendicular bisector, D(R0=2 mm, Z0=0). The first three are counterparts of the geometry factor, the anisotropy function and the radial dose function in the TG-60 formalism, respectively. The reference dose rate is identical to that recommended by TG-60. The distribution factor is intended to resemble the dose profile due to the spatial distribution of activity in the elongated beta source, and it is a modified Fermi-Dirac function in mathematical form. The utility of this formalism also includes the slow-varying nature of the modulation function, allowing for more accurate treatment planning calculations based on interpolation. The transverse dose function describes the exponential fall-off of the dose in the radial direction, and an exponential or a polynomial can fit it. Simultaneously, the decoupling nature of these dose-related quantities facilitates image-based 3D treatment planning calculations for long beta sources used in IVBT. The new formalism also supports the dosimetry involving multiple dwell positions required for lesions longer than the source length. An example of the utilization of this formalism is illustrated for a 90Y coil source in a carbon dioxide-filled balloon. The pertinent dosimetric parameters were generated and tabulated for future use.

  16. Phenols removal using ozonation-adsorption with granular activated carbon (GAC) in rotating packed bed reactor

    NASA Astrophysics Data System (ADS)

    Karamah, E. F.; Leonita, S.; Bismo, S.

    2018-01-01

    Synthetic wastewater containing phenols was treated using combination method of ozonation-adsorption with GAC (Granular Activated Carbon) in a packed bed rotating reactor. Ozone reacts quickly with phenol and activated carbon increases the oxidation process by producing hydroxyl radicals. Performance parameters evaluated are phenol removal percentage, the quantity of hydroxyl radical formed, changes in pH and ozone utilization, dissolved ozone concentration and ozone concentration in off gas. The performance of the combination method was compared with single ozonation and single adsorption. The influence of GAC dose and initial pH of phenols were evaluated in ozonation-adsorption method. The results show that ozonation-adsorption method generates more OH radicals than a single ozonation. Quantity of OH radical formation increases with increasing pH and quantity of the GAC. The combination method prove better performance in removing phenols. At the same operation condition, ozonation-adsorption method is capable of removing of 78.62% phenols as compared with single ozonation (53.15%) and single adsorption (36.67%). The increasing percentage of phenol removal in ozonation-adsorption method is proportional to the addition of GAC dose, solution pH, and packed bed rotator speed. Maximum percentage of phenol removal is obtained under alkaline conditions (pH 10) and 125 g of GAC

  17. Mumps Postexposure Prophylaxis with a Third Dose of Measles-Mumps-Rubella Vaccine, Orange County, New York, USA

    PubMed Central

    Lawler, Jacqueline; Curns, Aaron T.; Brandeburg, Christina; Wallace, Gregory S.

    2013-01-01

    Although the measles-mumps-rubella (MMR) vaccine is not recommended for mumps postexposure prophylaxis (PEP), data on its effectiveness are limited. During the 2009–2010 mumps outbreak in the northeastern United States, we assessed effectiveness of PEP with a third dose of MMR vaccine among contacts in Orthodox Jewish households who were given a third dose within 5 days of mumps onset in the household’s index patient. We compared mumps attack rates between persons who received a third MMR dose during the first incubation period after onset in the index patient and 2-dose vaccinated persons who had not. Twenty-eight (11.7%) of 239 eligible household members received a third MMR dose as PEP. Mumps attack rates were 0% among third-dose recipients versus 5.2% among 2-dose recipients without PEP (p = 0.57). Although a third MMR dose administered as PEP did not have a significant effect, it may offer some benefits in specific outbreak contexts. PMID:23965729

  18. SAFETY ANALYSIS REPORT FOR PACKAGING, MODEL 9977, ADDENDUM 3, JUSTIFICATION FOR SMALL GRAM QUANTITY CONTENTS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abramczyk, G.

    2011-10-31

    This Addendum establishes a new family of content envelopes consisting of small quantities of radioactive materials. These content envelopes and specific packing configurations are shown to be subcritical. However, the dose rates of some payloads must be measured and shown to comply with applicable radiation limits. Authorization for shipment of the content envelop requires acceptance of this Addendum by the DOE-HQ certifying official as a supplement to the 9977 SARP Revision 2 and DOE-HQ's subsequent revision of the CoC Revision 10 (which is based on SARP Addendum 2 and SARP Addendum 4) to authorize the additional content envelope. The Smallmore » Gram Quantity Content Envelopes and packing configurations will be incorporated in the next revision of the 9977 SARP.« less

  19. 14 CFR 125.9 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... OR MORE; AND RULES GOVERNING PERSONS ON BOARD SUCH AIRCRAFT General § 125.9 Definitions. (a) For the... total quantity of hydraulic fluid. (c) For the purposes of this part, maximum zero fuel weight means the...

  20. 14 CFR 125.9 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... OR MORE; AND RULES GOVERNING PERSONS ON BOARD SUCH AIRCRAFT General § 125.9 Definitions. (a) For the... total quantity of hydraulic fluid. (c) For the purposes of this part, maximum zero fuel weight means the...

  1. 14 CFR 125.9 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... OR MORE; AND RULES GOVERNING PERSONS ON BOARD SUCH AIRCRAFT General § 125.9 Definitions. (a) For the... total quantity of hydraulic fluid. (c) For the purposes of this part, maximum zero fuel weight means the...

  2. 14 CFR 125.9 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... OR MORE; AND RULES GOVERNING PERSONS ON BOARD SUCH AIRCRAFT General § 125.9 Definitions. (a) For the... total quantity of hydraulic fluid. (c) For the purposes of this part, maximum zero fuel weight means the...

  3. 14 CFR 125.9 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... OR MORE; AND RULES GOVERNING PERSONS ON BOARD SUCH AIRCRAFT General § 125.9 Definitions. (a) For the... total quantity of hydraulic fluid. (c) For the purposes of this part, maximum zero fuel weight means the...

  4. 19 CFR 171.51 - Application and definitions.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... hallucinogin or a cannabis-controlled substance will be considered in excess of personal use quantities if the... leaves, except coca leaves and extracts of coca leaves from which cocaine, ecgonine, and derivations of...

  5. 19 CFR 171.51 - Application and definitions.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... hallucinogin or a cannabis-controlled substance will be considered in excess of personal use quantities if the... leaves, except coca leaves and extracts of coca leaves from which cocaine, ecgonine, and derivations of...

  6. 19 CFR 171.51 - Application and definitions.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... hallucinogin or a cannabis-controlled substance will be considered in excess of personal use quantities if the... leaves, except coca leaves and extracts of coca leaves from which cocaine, ecgonine, and derivations of...

  7. Hepatitis A and Hepatitis B vaccination coverage among adults with chronic liver disease

    PubMed Central

    Yue, Xin; Black, Carla L.; O’Halloran, Alissa; Lu, Peng-Jun; Williams, Walter W.; Nelson, Noele P.

    2018-01-01

    Background Infection with hepatitis A and hepatitis B virus can increase the risk of morbidity and mortality in persons with chronic liver disease (CLD). The Advisory Committee on Immunization Practices recommends hepatitis A (HepA) and hepatitis B (HepB) vaccination for persons with CLD. Methods Data from the 2014 and 2015 National Health Interview Surveys (NHIS), nationally representative, in-person interview surveys of the non-institutionalized US civilian population, were used to assess self-reported HepA (≥1 and ≥2 doses) and HepB vaccination (≥1 and ≥3 doses) coverage among adults who reported a chronic or long-term liver condition. Multivariable logistic regression was used to identify factors independently associated with HepA and HepB vaccination among adults with CLD. Results Overall, 19.4% and 11.5% of adults aged ≥18 years with CLD reported receiving ≥1 dose and ≥2 doses of HepA vaccine, respectively, compared with 14.7% and 9.1% of adults without CLD (p<0.05 comparing those with and without CLD, ≥1dose). Age, education, geographic region, and international travel were associated with receipt of ≥2 doses HepA vaccine among adults with CLD. Overall, 35.7% and 29.1% of adults with CLD reported receiving ≥1 dose and ≥3 doses of HepB vaccine, respectively, compared with 30.2% and 24.7% of adults without CLD (p<0.05 comparing those with and without CLD, ≥1 dose). Age, education, and receipt of influenza vaccination in the past 12 months were associated with receipt of ≥3 doses HepB vaccine among adults with CLD. Among adults with CLD and ≥10 provider visits, only 13.8% and 35.3% had received ≥2 doses HepA and ≥3 doses HepB vaccine, respectively. Conclusions HepA and HepB vaccination among adults with CLD is suboptimal and missed opportunities to vaccinate occurred. Providers should adhere to recommendations to vaccinate persons with CLD to increase vaccination among this population. PMID:29395521

  8. Hepatitis A and hepatitis B vaccination coverage among adults with chronic liver disease.

    PubMed

    Yue, Xin; Black, Carla L; O'Halloran, Alissa; Lu, Peng-Jun; Williams, Walter W; Nelson, Noele P

    2018-02-21

    Infection with hepatitis A and hepatitis B virus can increase the risk of morbidity and mortality in persons with chronic liver disease (CLD). The Advisory Committee on Immunization Practices recommends hepatitis A (HepA) and hepatitis B (HepB) vaccination for persons with CLD. Data from the 2014 and 2015 National Health Interview Surveys (NHIS), nationally representative, in-person interview surveys of the non-institutionalized US civilian population, were used to assess self-reported HepA (≥1 and ≥2 doses) and HepB vaccination (≥1 and ≥3 doses) coverage among adults who reported a chronic or long-term liver condition. Multivariable logistic regression was used to identify factors independently associated with HepA and HepB vaccination among adults with CLD. Overall, 19.4% and 11.5% of adults aged ≥ 18 years with CLD reported receiving ≥1 dose and ≥2 doses of HepA vaccine, respectively, compared with 14.7% and 9.1% of adults without CLD (p < .05 comparing those with and without CLD, ≥1dose). Age, education, geographic region, and international travel were associated with receipt of ≥2 doses HepA vaccine among adults with CLD. Overall, 35.7% and 29.1% of adults with CLD reported receiving ≥1 dose and ≥3 doses of HepB vaccine, respectively, compared with 30.2% and 24.7% of adults without CLD (p < .05 comparing those with and without CLD, ≥1 dose). Age, education, and receipt of influenza vaccination in the past 12 months were associated with receipt of ≥3 doses HepB vaccine among adults with CLD. Among adults with CLD and ≥10 provider visits, only 13.8% and 35.3% had received ≥2 doses HepA and ≥3 doses HepB vaccine, respectively. HepA and HepB vaccination among adults with CLD is suboptimal and missed opportunities to vaccinate occurred. Providers should adhere to recommendations to vaccinate persons with CLD to increase vaccination among this population. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. EPR TOOTH DOSIMETRY OF SNTS AREA INHABITANTS

    PubMed Central

    Sholom, Sergey; Desrosiers, Marc; Bouville, André; Luckyanov, Nicholas; Chumak, Vadim

    2009-01-01

    The determination of external dose to teeth of inhabitants of settlements near the Semipalatinsk Nuclear Test Site (SNTS) was conducted using the EPR dosimetry technique to assess radiation doses associated with exposure to radioactive fallout from the test site. In this study, tooth doses have been reconstructed for 103 persons with all studied teeth having been formed before the first nuclear test in 1949. Doses above those received from natural background radiation, termed “accident doses”, were found to lie in the range from zero to approximately 2 Gy, with one exception, a dose for one person from Semipalatinsk city was approximately 9 Gy. The variability of reconstructed doses within each of the settlements demonstrated heterogeneity of the deposited fallout as well as variations in lifestyle. The village mean external gamma doses for residents of nine[ settlements were in the range from a few tens of mGy to approximately 100 mGy. PMID:19590746

  10. A novel algorithm for the calculation of physical and biological irradiation quantities in scanned ion beam therapy: the beamlet superposition approach

    NASA Astrophysics Data System (ADS)

    Russo, G.; Attili, A.; Battistoni, G.; Bertrand, D.; Bourhaleb, F.; Cappucci, F.; Ciocca, M.; Mairani, A.; Milian, F. M.; Molinelli, S.; Morone, M. C.; Muraro, S.; Orts, T.; Patera, V.; Sala, P.; Schmitt, E.; Vivaldo, G.; Marchetto, F.

    2016-01-01

    The calculation algorithm of a modern treatment planning system for ion-beam radiotherapy should ideally be able to deal with different ion species (e.g. protons and carbon ions), to provide relative biological effectiveness (RBE) evaluations and to describe different beam lines. In this work we propose a new approach for ion irradiation outcomes computations, the beamlet superposition (BS) model, which satisfies these requirements. This model applies and extends the concepts of previous fluence-weighted pencil-beam algorithms to quantities of radiobiological interest other than dose, i.e. RBE- and LET-related quantities. It describes an ion beam through a beam-line specific, weighted superposition of universal beamlets. The universal physical and radiobiological irradiation effect of the beamlets on a representative set of water-like tissues is evaluated once, coupling the per-track information derived from FLUKA Monte Carlo simulations with the radiobiological effectiveness provided by the microdosimetric kinetic model and the local effect model. Thanks to an extension of the superposition concept, the beamlet irradiation action superposition is applicable for the evaluation of dose, RBE and LET distributions. The weight function for the beamlets superposition is derived from the beam phase space density at the patient entrance. A general beam model commissioning procedure is proposed, which has successfully been tested on the CNAO beam line. The BS model provides the evaluation of different irradiation quantities for different ions, the adaptability permitted by weight functions and the evaluation speed of analitical approaches. Benchmarking plans in simple geometries and clinical plans are shown to demonstrate the model capabilities.

  11. Dosimetric Quantities for Computed Tomography Examinations of Paediatric Patients on the Thoracic and Abdominal Regions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flores-M, E.; Gamboa de Buen, I.; Buenfil, A. E.

    Computed Tomography (CT) is a high dose X ray imaging procedure and its use has rapidly increased in the last two decades fueled by the development of helical CT. The aim of this study is to present values of the dosimetric quantities for CT paediatric examinations of thoracic and abdominal regions. The protocols studied were those of chest, lung-mediastine, chest-abdomen, pulmonary high resolution and mediastine-abdomen, which are the more common examinations performed at ''Hospital Infantil de Mexico Federico Gomez'' in the thoracic-abdominal region. The measurements were performed on a Siemens SOMATOM Sensation 16 CT Scanner and the equipment used wasmore » a CT pencil ionization chamber, connected to an electrometer. This system was calibrated for RQT9 CT beam quality. A PMMA head phantom with diameter of 16 cm and length of 15 cm was also used. The dosimetric quantities measured were the weighted air kerma index (C{sub w}), the volumetric dose index (C{sub vol}) and the CT air kerma-length product. It was found that the pulmonary high resolution examination presented the highest values for the C{sub w}(31.1 mGy) and C{sub vol}(11.1 mGy). The examination with the lowest values of these two quantities was the chest-abdomen protocol with 10.5 mGy for C{sub w} and 5.5 mGy for C{sub vol}. However, this protocol presented the highest value for P{sub KL,CT}(282.2 mGy cm) when considering the average clinical length of the examinations.« less

  12. Microplastics in personal care products: Exploring perceptions of environmentalists, beauticians and students.

    PubMed

    Anderson, A G; Grose, J; Pahl, S; Thompson, R C; Wyles, K J

    2016-12-15

    Microplastics enter the environment as a result of larger plastic items breaking down ('secondary') and from particles originally manufactured at that size ('primary'). Personal care products are an important contributor of secondary microplastics (typically referred to as 'microbeads'), for example in toothpaste, facial scrubs and soaps. Consumers play an important role in influencing the demand for these products and therefore any associated environmental consequences. Hence we need to understand public perceptions in order to help reduce emissions of microplastics. This study explored awareness of plastic microbeads in personal care products in three groups: environmental activists, trainee beauticians and university students in South West England. Focus groups were run, where participants were shown the quantity of microbeads found in individual high-street personal care products. Qualitative analysis showed that while the environmentalists were originally aware of the issue, it lacked visibility and immediacy for the beauticians and students. Yet when shown the amount of plastic in a range of familiar everyday personal care products, all participants expressed considerable surprise and concern at the quantities and potential impact. Regardless of any perceived level of harm in the environment, the consensus was that their use was unnatural and unnecessary. This research could inform future communications with the public and industry as well as policy initiatives to phase out the use of microbeads. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Lung Cancer Screening Using Low Dose CT Scanning in Germany. Extrapolation of results from the National Lung Screening Trial.

    PubMed

    Stang, Andreas; Schuler, Martin; Kowall, Bernd; Darwiche, Kaid; Kühl, Hilmar; Jöckel, Karl-Heinz

    2015-09-18

    It is now debated whether the screening of heavy smokers for lung cancer with low dose computed tomography (low dose CT) might lower their mortality due to lung cancer. We use data from the National Lung Screening Trial (NLST) in the USA to predict the likely effects of such screening in Germany. The number of heavy smokers aged 55-74 in Germany was extrapolated from survey data obtained by the Robert Koch Institute. Published data from the NLST were then used to estimate the likely effects of low dose CT screening of heavy smokers in Germany. If low dose CT screening were performed on 50% of the heavy smokers in Germany aged 55-74, an estimated 1 329 506 persons would undergo such screening. If the screening were repeated annually, then, over three years, 916 918 screening CTs would reveal suspect lesions, and the diagnosis of lung cancer would be confirmed thereafter in 32 826 persons. At least one positive test result in three years would be obtained in 39.1% of the participants (519 837 persons). 4155 deaths from lung cancer would be prevented over 6.5 years, and the number of persons aged 55-74 who die of lung cancer in Germany would fall by 2.6%. 12 449 persons would have at least one complication, and 1074 persons would die in the 60 days following screening. The screening of heavy smokers for lung cancer can lower their risk of dying of lung cancer by 20% in relative terms, corresponding to an absolute risk reduction of 0.3 percentage points. These figures can provide the background for a critical discussion of the putative utility of this type of screening in Germany.

  14. Energy Drinks and Binge Drinking Predict College Students' Sleep Quantity, Quality, and Tiredness.

    PubMed

    Patrick, Megan E; Griffin, Jamie; Huntley, Edward D; Maggs, Jennifer L

    2018-01-01

    This study examines whether energy drink use and binge drinking predict sleep quantity, sleep quality, and next-day tiredness among college students. Web-based daily data on substance use and sleep were collected across four semesters in 2009 and 2010 from 667 individuals for up to 56 days each, yielding information on 25,616 person-days. Controlling for average levels of energy drink use and binge drinking (i.e., 4+ drinks for women, 5+ drinks for men), on days when students consumed energy drinks, they reported lower sleep quantity and quality that night, and greater next-day tiredness, compared to days they did not use energy drinks. Similarly, on days when students binge drank, they reported lower sleep quantity and quality that night, and greater next-day tiredness, compared to days they did not binge drink. There was no significant interaction effect between binge drinking and energy drink use on the outcomes.

  15. Dose commitments due to radioactive releases from nuclear power plant sites: Methodology and data base. Supplement 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.

    1996-06-01

    This manual describes a dose assessment system used to estimate the population or collective dose commitments received via both airborne and waterborne pathways by persons living within a 2- to 80-kilometer region of a commercial operating power reactor for a specific year of effluent releases. Computer programs, data files, and utility routines are included which can be used in conjunction with an IBM or compatible personal computer to produce the required dose commitments and their statistical distributions. In addition, maximum individual airborne and waterborne dose commitments are estimated and compared to 10 CFR Part 50, Appendix 1, design objectives. Thismore » supplement is the last report in the NUREG/CR-2850 series.« less

  16. Transferring mixtures of chemicals from sediment to a bioassay using silicone-based passive sampling and dosing.

    PubMed

    Mustajärvi, Lukas; Eriksson-Wiklund, Ann-Kristin; Gorokhova, Elena; Jahnke, Annika; Sobek, Anna

    2017-11-15

    Environmental mixtures of chemicals consist of a countless number of compounds with unknown identity and quantity. Yet, chemical regulation is mainly built around the assessment of single chemicals. Existing frameworks for assessing the toxicity of mixtures require that both the chemical composition and quantity are known. Quantitative analyses of the chemical composition of environmental mixtures are however extremely challenging and resource-demanding. Bioassays may therefore serve as a useful approach for investigating the combined toxicity of environmental mixtures of chemicals in a cost-efficient and holistic manner. In this study, an unknown environmental mixture of bioavailable semi-hydrophobic to hydrophobic chemicals was sampled from a contaminated sediment in a coastal Baltic Sea area using silicone polydimethylsiloxane (PDMS) as an equilibrium passive sampler. The chemical mixture was transferred to a PDMS-based passive dosing system, and its applicability was demonstrated using green algae Tetraselmis suecica in a cell viability assay. The proportion of dead cells increased significantly with increasing exposure level and in a dose-response manner. At an ambient concentration, the proportion of dead cells in the population was nearly doubled compared to the control; however, the difference was non-significant due to high inter-replicate variability and a low number of replicates. The validation of the test system regarding equilibrium sampling, loading efficiency into the passive dosing polymer, stability of the mixture composition, and low algal mortality in control treatments demonstrates that combining equilibrium passive sampling and passive dosing is a promising tool for investigating the toxicity of bioavailable semi-hydrophobic and hydrophobic chemicals in complex environmental mixtures.

  17. Comparative Cost Analysis of Sequential, Adaptive, Behavioral, Pharmacological, and Combined Treatments for Childhood ADHD

    PubMed Central

    Page, Timothy F.; Fabiano, Gregory A.; Greiner, Andrew R.; Gnagy, Elizabeth M.; Pelham, William E.; Hart, Katie; Coxe, Stefany; Waxmonsky, James G.; Pelham, William E.

    2016-01-01

    Objective We conducted a cost-analysis of the behavioral, pharmacological, and combined interventions employed in a sequential, multiple assignment randomized, and adaptive trial investigating the sequencing and enhancement of treatment for ADHD children (Pelham et al., under review; N=152, 76% male, 80% Caucasian). Methods The quantity of resources expended on each child’s treatment was determined from records that listed the type, date, location, persons present, and duration of all services provided. The inputs considered were the amount of physician time, clinician time, paraprofessional time, teacher time, parent time, medication, and gasoline. Quantities of these inputs were converted into costs in 2013 USD using national wage estimates from the Bureau of Labor Statistics, the prices of 30-day supplies of prescription drugs from the national Express Scripts service, and mean fuel prices from the Energy Information Administration. Results Beginning treatment with a low-intensity regimen of behavior modification (group parent training) was less costly for a school-year of treatment ($961) than beginning treatment with a low dose of stimulant medication ($1689), regardless of whether the initial treatment was intensified with a higher “dose” or if the other modality was added. Conclusions Outcome data from the parent study (Pelham et al., under review) found equivalent or superior outcomes for treatments beginning with low-intensity behavior modification compared to intervention beginning with medication. Combined with the present analyses, these findings document that initiating treatment with behavior modification rather than medication is the more cost-effective option for children with ADHD. PMID:26808137

  18. Approximation of personal exposure to fine particulate matters (PM2.5) during cooking using solid biomass fuels in the kitchens of rural West Bengal, India.

    PubMed

    Nayek, Sukanta; Padhy, Pratap Kumar

    2018-06-01

    More than 85% of the rural Indian households use traditional solid biofuels (SBFs) for daily cooking. Burning of the easily available unprocessed solid fuels in inefficient earthen cooking stoves produce large quantities of particulate matters. Smaller particulates, especially with aerodynamic diameter of 2.5 μm or less (PM 2.5 ), largely generated during cooking, are considered to be health damaging in nature. In the present study, kitchen level exposure of women cooks to fine particulate matters during lunch preparation was assessed considering kitchen openness as surrogate to the ventilation condition. Two-way ANCOVA analysis considering meal quantity as a covariate revealed no significant interaction between the openness and the seasons explaining the variability of the personal exposure to the fine particulate matters in rural kitchen during cooking. Multiple linear regression analysis revealed the openness as the only significant predictor for personal exposure to the fine particulate matters. In the present study, the annual average fine particulate matter exposure concentration was found to be 974 μg m -3 .

  19. A U.S. Multicenter Study of Recorded Occupational Radiation Badge Doses in Nuclear Medicine.

    PubMed

    Villoing, Daphnée; Yoder, R Craig; Passmore, Christopher; Bernier, Marie-Odile; Kitahara, Cari M

    2018-05-01

    Purpose To summarize occupational badge doses recorded for a sample of U.S. nuclear medicine technologists. Materials and Methods Nine large U.S. medical institutions identified 208 former and current nuclear medicine technologists certified after 1979 and linked these individuals to historic badge dose records maintained by a commercial dosimetry company (Landauer), yielding a total of 2618 annual dose records. The distributions of annual and cumulative occupational doses were described by using summary statistics. Results Between 1992 and 2015, the median annual personal dose equivalent per nuclear medicine technologist was 2.18 mSv (interquartile range [IQR], 1.25-3.47 mSv; mean, 2.69 mSv). Median annual personal dose equivalents remained relatively constant over this period (range, 1.40-3.30 mSv), while maximum values generally increased over time (from 8.00 mSv in 1992 to 13.9 mSv in 2015). The median cumulative personal dose equivalent was 32.9 mSv (IQR, 18.1-65.5 mSv; mean, 51.4 mSv) for 45 technologists who had complete information and remained employed through 2015. Conclusion Occupational radiation doses were well below the established occupational limits and were consistent with those observed for nuclear medicine technologists worldwide and were greater than those observed for nuclear and general medical workers in the United States These results should be informative for radiation monitoring and safety efforts in nuclear medicine departments. © RSNA, 2018 Online supplemental material is available for this article.

  20. Assessing doses to interventional radiologists using a personal dosimeter worn over a protective apron.

    PubMed

    Stranden, E; Widmark, A; Sekse, T

    2008-05-01

    Interventional radiologists receive significant radiation doses, and it is important to have simple methods for routine monitoring of their exposure. To evaluate the usefulness of a dosimeter worn outside the protective apron for assessments of dose to interventional radiologists. Assessments of effective dose versus dose to dosimeters worn outside the protective apron were achieved by phantom measurements. Doses outside and under the apron were assessed by phantom measurements and measurements on eight radiologists wearing two routine dosimeters for a 2-month period during ordinary working conditions. Finger doses for the same radiologists were recorded using thermoluminescent dosimeters (TLD; DXT-RAD Extremity dosimeters). Typical values for the ratio between effective dose and dosimeter dose were found to be about 0.02 when the radiologist used a thyroid shield and about 0.03 without. The ratio between the dose to the dosimeter under and outside a protective apron was found to be less than 0.04. There was very good correlation between finger dose and dosimeter dose. A personal dosimeter worn outside a protective apron is a good screening device for dose to the eyes and fingers as well as for effective dose, even though the effective dose is grossly overestimated. Relatively high dose to the fingers and eyes remains undetected by a dosimeter worn under the apron.

  1. Physics From the News -- Fukushima Daiichi: Radiation Doses and Dose Rates

    NASA Astrophysics Data System (ADS)

    Bartlett, A. A.

    2011-09-01

    The nuclear disaster that was triggered by the Japanese earthquake and the following tsunami of March 11, 2011, continues to be the subject of a great deal of news coverage. The tsunami caused severe damage to the nuclear power reactors at Fukushima Daiichi, and this led to the escape of unknown quantities of radioactive material from the damaged fuel rods in the reactors and from the associated storage facilities for the fuel rods that had been removed from the reactors.

  2. Radiation Measured with Different Dosimeters for ISS-Expedition 18-19/ULF2 on Board International Space Station during Solar Minimum

    NASA Technical Reports Server (NTRS)

    Zhou, Dazhuang; Gaza, R.; Roed, Y.; Semones, E.; Lee, K.; Steenburgh, R.; Johnson, S.; Flanders, J.; Zapp, N.

    2010-01-01

    Radiation field of particles in low Earth orbit (LEO) is mainly composed of galactic cosmic rays (GCR), solar energetic particles and particles in SAA (South Atlantic Anomaly). GCR are modulated by solar activity, at the period of solar minimum activity, GCR intensity is at maximum and the main contributor for space radiation is GCR. At present for space radiation measurements conducted by JSC (Johnson Space Center) SRAG (Space Radiation Analysis Group), the preferred active dosimeter sensitive to all LET (Linear Energy Transfer) is the tissue equivalent proportional counter (TEPC); the preferred passive dosimeters are thermoluminescence dosimeters (TLDs) and optically stimulated luminescence dosimeters (OSLDs) sensitive to low LET as well as CR-39 plastic nuclear track detectors (PNTDs) sensitive to high LET. For the method using passive dosimeters, radiation quantities for all LET can be obtained by combining radiation results measured with TLDs/OSLDs and CR-39 PNTDs. TEPC, TLDs/OSLDs and CR-39 detectors were used to measure the radiation field for the ISS (International Space Station) - Expedition 18-19/ULF2 space mission which was conducted from 15 November 2008 to 31 July 2009 - near the period of the recent solar minimum activity. LET spectra (differential and integral fluence, absorbed dose and dose equivalent) and radiation quantities were measured for positions TEPC, TESS (Temporary Sleeping Station, inside the polyethylene lined sleep station), SM-P 327 and 442 (Service Module - Panel 327 and 442). This paper presents radiation LET spectra measured with TEPC and CR-39 PNTDs and radiation dose measured with TLDs/OSLDs as well as the radiation quantities combined from results measured with passive dosimeters.

  3. A correlation study of eye lens dose and personal dose equivalent for interventional cardiologists.

    PubMed

    Farah, J; Struelens, L; Dabin, J; Koukorava, C; Donadille, L; Jacob, S; Schnelzer, M; Auvinen, A; Vanhavere, F; Clairand, I

    2013-12-01

    This paper presents the dosimetry part of the European ELDO project, funded by the DoReMi Network of Excellence, in which a method was developed to estimate cumulative eye lens doses for past practices based on personal dose equivalent values, H(p)(10), measured above the lead apron at several positions at the collar, chest and waist levels. Measurement campaigns on anthropomorphic phantoms were carried out in typical interventional settings considering different tube projections and configurations, beam energies and filtration, operator positions and access routes and using both mono-tube and biplane X-ray systems. Measurements showed that eye lens dose correlates best with H(p)(10) measured on the left side of the phantom at the level of the collar, although this correlation implicates high spreads (41 %). Nonetheless, for retrospective dose assessment, H(p)(10) records are often the only option for eye dose estimates and the typically used chest left whole-body dose measurement remains useful.

  4. Assessment of radiation doses from residential smoke detectors that contain americium-241

    NASA Astrophysics Data System (ADS)

    Odonnell, F. R.; Etnier, E. L.; Holton, G. A.; Travis, C. C.

    1981-10-01

    External dose equivalents and internal dose commitments were estimated for individuals and populations from annual distribution, use, and disposal of 10 million ionization chamber smoke detectors that contain 110 kBq americium-241 each. Under exposure scenarios developed for normal distribution, use, and disposal using the best available information, annual external dose equivalents to average individuals were estimated to range from 4 fSv to 20 nSv for total body and from 7 fSv to 40 nSv for bone. Internal dose commitments to individuals under post disposal scenarios were estimated to range from 0.006 to 80 micro-Sv (0.0006 to 8 mrem) to total body and from 0.06 to 800 micro-Sv to bone. The total collective dose (the sum of external dose equivalents and 50-year internal dose commitments) for all individuals involved with distribution, use, or disposal of 10 million smoke detectors was estimated to be about 0.38 person-Sv (38 person-rem) to total body and 00 ft squared.

  5. Deposition and dose from the 18 May 1980 eruption of Mount St. Helens

    NASA Technical Reports Server (NTRS)

    Peterson, K. R.

    1982-01-01

    The downwind deposition and radiation doses was calculated for the tropospheric part of the ash cloud from the May 18, 1980 eruption of Mount St. Helens, by using a large cloud diffusion model. The naturally occurring radionnuclides of radium and thorium, whose radon daughters normally seep very slowly from the rocks and soil, were violently released to the atmosphere. The largest dose to an individual from these nuclides is small, but the population dose to those affected by the radioactivity in the ash is about 100 person rem. This population dose from Mount St. Helens is much greater than the annual person rem routinely released by a typical large nuclear power plant. It is estimated that subsequent eruptions of Mount St. Helens have doubled or tripled the person rem calculated from the initial large eruption. The long range global ash deposition of the May 18 eruption is estimated through 1984, by use of a global deposition model. The maximum deposition is nearly 1000 kg square km and occurs in the spring of 1981 over middle latitudes of the Northern Hemisphere.

  6. Assessing personality in San Joaquin kit fox in situ: efficacy of field-based experimental methods and implications for conservation management.

    PubMed

    Bremner-Harrison, Samantha; Cypher, Brian L; Van Horn Job, Christine; Harrison, Stephen W R

    2018-01-01

    Utilisation of animal personality has potential benefit for conservation management. Due to logistics of robust behavioural evaluation in situ, the majority of studies on wild animals involve taking animals into captivity for testing, potentially compromising results. Three in situ tests for evaluation of boldness in San Joaquin kit fox ( Vulpes macrotis mutica ) were developed (ENOT: extended novel object test; RNOT: rapid novel object test; TH: trap/handling test). Each test successfully identified variation in boldness within its target age class(es). The TH test was suitable for use across all age classes. Tests were assessed for in situ suitability and for quantity/quality of data yielded. ENOT was rated as requiring high levels of time, cost and labour with greater likelihood of failure. However, it was rated highly for data quantity/quality. The TH test was rated as requiring little time, labour and cost, but yielding lower quality data. RNOT was rated in the middle. Each test had merit and could be adapted to suit project or species constraints. We recommend field-based evaluation of personality, reducing removal of animals from the wild and facilitating routine incorporation of personality assessment into conservation projects.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    Complete texts of 123 communications to the Congress (in the original language; the majority in English, some in Russian, French), on the following topics; radiation perspective in the U.S., radiation and man, non-ionising radiation, radiation effects on animals, radiation quantities, radioecology, reactor experience, late radiation effects, dose calculations and radiation accidents.

  8. Effect of dexamethasone on expression of glucocorticoid receptor in human monocyte cell line THP-1.

    PubMed

    Li, Bo; Bai, Xiangjun; Wanh, Haiping

    2006-01-01

    The effect of dexamethasone with different concentrations and different stimulating periods on the expression of glucocorticoid receptors (GRalpha, GRbeta) protein was investigated in human monocyte cell line THP-1. The cultured human monocyte line THP-1 cells were stimulated by dexamethasone with different concentrations and different periods. The expression of GRalpha and GRbeta protein was detected by Western blotting. The results showed that the expression of GRalpha and GRbeta was detected in the THP-1 cells. The quantity of GRalpha expression was reduced by dexamethasone under the same concentration with the prolongation of the stimulating periods. The quantity of GRbeta expression was increased by dexamethasone treatment in a time- and dose-dependent manner. It was concluded that dexamethasone stimulation time-dependently reduced the GRalpha expression in THP-1 cells. Dexamethasone stimulation time- and dose-dependently increased the GRbeta expression in THP-1 cells. The expression of GRalpha and GRbeta was regulated by glucocorticoid.

  9. [Treatment of cetyltrimethyl ammonium bromide wastewater by potassium ferrate].

    PubMed

    Yang, Wei-hua; Wang, Hong-hui; Zeng, Xiao-xu; Huang, Ting-ting

    2009-08-15

    A novel oxidant potassium ferrate (K2FeO4) was used to remove cetyltrimethyl ammonium bromide (CTAB) at room temperature. The effects of various conditions on the removal ratio, such as reaction time, dosing quantity of K2FeO4 and initial pH, were investigated. The experiments results show that the removal ratio reaches 79.4% when the reaction time is 30 min, the dosing quantity of K2FeO4 to CTAB is 1:1, the initial pH of the solution is 7. In the reaction progress, the oxidation of K2FeO4 and the flocculation of the reduction product have synergistic effect on the removal of CTAB. In addition, infrared spectra of CTAB before and after being treated with K2FeO4 were further studied. The results indicate that the degradation process involves the interruption of chain and the subsequent mineralization to inorganic molecules. Furthermore, the reaction of K2FeO4 and CTAB follows second order kinetics law.

  10. Evaluation of a New Equation for Calculating the Maximum Wait Time for Pilots That Have Used an Impairing Medication

    DTIC Science & Technology

    2013-08-01

    were treating pre-existing medical conditions using over-the-counter (OTC) medications ( Aspirin ™, Tylenol™, antihistamines, etc.), provided blood...time would decrease to 45 hours for a 150-lb person taking the same dose; a 300 -lb individual taking a 25-mg dose would only need to wait 31 hours...If the 300 -lb person mentioned above had taken a 50- mg dose, the wait time would have been 45 hours, which is approximately the same as the 49

  11. Development of a personal dosimetry system based on optically stimulated luminescence of alpha-Al2O3:C for mixed radiation fields.

    PubMed

    Lee, S Y; Lee, K J

    2001-04-01

    To develop a personal optically stimulated luminescence (OSL) dosimetry system for mixed radiation fields using alpha-Al2O3:C, a discriminating badge filter system was designed by taking advantage of its optically stimulable properties and energy dependencies. This was done by designing a multi-element badge system for powder layered alpha-Al2O3:C material and an optical reader system based on high-intensity blue light-emitting diode (LED). The design of the multielement OSL dosimeter badge system developed allows the measurement of a personal dose equivalent value Hp(d) in mixed radiation fields of beta and gamma. Dosimetric properties of the personal OSL dosimeter badge system investigated here were the dose response, energy response and multi-readability. Based on the computational simulations and experiments of the proposed dosimeter design, it was demonstrated that a multi-element dosimeter system with an OSL technology based on alpha-Al2O3:C is suitable to obtain personal dose equivalent information in mixed radiation fields.

  12. Mercury concentration in the muscle of seven fish species from Chagan Lake, Northeast China.

    PubMed

    Zhu, Lilu; Yan, Baixing; Wang, Lixia; Pan, Xiaofeng

    2012-03-01

    Chagan Lake is located downstream of the Second Songhua River basin in Northeast China. It is one of the top ten inland freshwater lakes, and an important aquatic farm in China. The lake has been receiving large amounts (currently at 1.5 × 10(8) m(3)/a) of water from the river since 1984. This would pose a threat to the aquatic system of the lake because the river was seriously polluted with mercury in 1970s-1980s. The current study is the first to report the total mercury concentrations in fish found in the lake. Mercury concentrations in seven fish species collected from the lake in January 2009 were determined. The related human health risk from fish consumption was also assessed. The average concentration of mercury in the fish was 18.8 μg/kg of wet weight, ranging from 4.5 to 37.6 μg/kg of wet weight. A large difference in the mercury concentrations among the fish species was found. The mercury concentration was found to be higher in carnivorous species and lower in omnivorous and herbivorous species. This demonstrates greater mercury bioaccumulation in fish species at higher trophic levels. Mercury concentrations in fish showed significant positive correlations with age, length, and weight. No significant relationship was found between mercury concentrations in fish and the habitat preferences. Mercury concentrations in fish from the lake were within the limits of the international and national standards of China established for mercury. According to the reference doses established by the United States Environmental Protection Agency, the maximum safe consuming quantity considering all the fish was 297.3 g/day/person, which was more than five times as much as the current quantity (50 g/day/person) consumed by the local residents. This investigation indicates that the historical pollution of the Second Songhua River has not caused mercury bioaccumulation in fish muscle tissue of Chagan Lake. The present consumption of fish from the lake in the local area does not pose a threat to human health.

  13. Positive Emotion Correlates of Meditation Practice: A Comparison of Mindfulness Meditation and Loving-kindness Meditation.

    PubMed

    Fredrickson, Barbara L; Boulton, Aaron J; Firestine, Ann M; Van Cappellen, Patty; Algoe, Sara B; Brantley, Mary M; Kim, Sumi Loundon; Brantley, Jeffrey; Salzberg, Sharon

    2017-12-01

    The purpose of this study was to uncover the day-to-day emotional profiles and dose-response relations, both within-persons and between-persons, associated with initiating one of two meditation practices, either mindfulness meditation or loving-kindness meditation. Data were pooled across two studies of midlife adults ( N = 339) who were randomized to learn either mindfulness meditation or loving-kindness meditation in a six-week workshop. The duration and frequency of meditation practice was measured daily for nine weeks, commencing with the first workshop session. Likewise, positive and negative emotions were also measured daily, using the modified Differential Emotions Scale (Fredrickson, 2013). Analysis of daily emotion reports over the targeted nine-week period showed significant gains in positive emotions and no change in negative emotions, regardless of meditation type. Multilevel models also revealed significant dose-response relations between duration of meditation practice and positive emotions, both within-persons and between-persons. Moreover, the within-person dose-response relation was stronger for loving-kindness meditation than for mindfulness meditation. Similar dose-response relations were observed for the frequency of meditation practice. In the context of prior research on the mental and physical health benefits produced by subtle increases in day-to-day experiences of positive emotions, the present research points to evidence-based practices - both mindfulness meditation and loving-kindness meditation - that can improve emotional wellbeing.

  14. Singlet oxygen explicit dosimetry to predict local tumor control for HPPH-mediated photodynamic therapy

    NASA Astrophysics Data System (ADS)

    Penjweini, Rozhin; Kim, Michele M.; Ong, Yi Hong; Zhu, Timothy C.

    2017-02-01

    This preclinical study examines four dosimetric quantities (light fluence, photosensitizer photobleaching ratio, PDT dose, and reacted singlet oxygen ([1O2]rx)) to predict local control rate (LCR) for 2-(1-Hexyloxyethyl)-2-devinyl pyropheophorbide (HPPH)-mediated photodynamic therapy (PDT). Mice bearing radiation-induced fibrosarcoma (RIF) tumors were treated with different in-air fluences (135, 250 and 350 J/cm2) and in-air fluence rates (50, 75 and 150 mW/cm2) at 0.25 mg/kg HPPH and a drug-light interval of 24 hours using a 1 cm diameter collimated laser beam at 665 nm wavelength. A macroscopic model was used to calculate ([1O2]rx)) based on in vivo explicit dosimetry of the initial tissue oxygenation, photosensitizer concentration, and tissue optical properties. PDT dose was defined as a temporal integral of drug concentration and fluence rate (φ) at a 3 mm tumor depth. Light fluence rate was calculated throughout the treatment volume based on Monte-Carlo simulation and measured tissue optical properties. The tumor volume of each mouse was tracked for 30 days after PDT and Kaplan-Meier analyses for LCR were performed based on a tumor volume <=100 mm3, for four dose metrics: fluence, HPPH photobleaching rate, PDT dose, and ([1O2]rx)). The results of this study showed that ([1O2]rx)) is the best dosimetric quantity that can predict tumor response and correlate with LCR.

  15. Templates and existing elements and models for implementation of patient exposure tracking.

    PubMed

    Rehani, Madan M; Berris, Theocharis

    2014-01-01

    There is wide interest currently in patient exposure tracking. This paper provides templates for implementation of tracking at the practice (hospital) level, multi-practice level, national level and international level. It provides suggestions for implementation in less-resourced countries. It includes elements such as patient identifier, dose quantities that should be covered and how to make sense from dose figures, availability of digital imaging and communications in medicine files with dose information or structured dose reports and capabilities of picture archiving and communication system (PACS). While tracking at several hospitals in a country connected by PACS and nationwide PACS is also a reality, tracking at the international level is currently a challenge. Guidance provided in this paper will facilitate its implementation at all levels.

  16. Recommendation of the Advisory Committee on Immunization Practices for Use of a Third Dose of Mumps Virus-Containing Vaccine in Persons at Increased Risk for Mumps During an Outbreak.

    PubMed

    Marin, Mona; Marlow, Mariel; Moore, Kelly L; Patel, Manisha

    2018-01-12

    A substantial increase in the number of mumps outbreaks and outbreak-associated cases has occurred in the United States since late 2015 (1,2). To address this public health problem, the Advisory Committee on Immunization Practices (ACIP) reviewed the available evidence and determined that a third dose of measles, mumps, rubella (MMR) vaccine is safe and effective at preventing mumps. During its October 2017 meeting, ACIP recommended a third dose of a mumps virus-containing vaccine* for persons previously vaccinated with 2 doses who are identified by public health authorities as being part of a group or population at increased risk for acquiring mumps because of an outbreak. The purpose of the recommendation is to improve protection of persons in outbreak settings against mumps disease and mumps-related complications. This recommendation supplements the existing ACIP recommendations for mumps vaccination (3).

  17. Estimations of the lethal and exposure doses for representative methanol symptoms in humans.

    PubMed

    Moon, Chan-Seok

    2017-01-01

    The aim of this review was to estimate the lethal and exposure doses of a representative symptom (blindness) of methanol exposure in humans by reviewing data from previous articles. Available articles published from 1970 to 2016 that investigated the dose-response relationship for methanol exposure (i.e., the exposure concentration and the biological markers/clinical symptoms) were evaluated; the MEDLINE and RISS (Korean search engine) databases were searched. The available data from these articles were carefully selected to estimate the range and median of a lethal human dose. The regression equation and correlation coefficient (between the exposure level and urinary methanol concentration as a biological exposure marker) were assumed from the previous data. The lethal human dose of pure methanol was estimated at 15.8-474 g/person as a range and as 56.2 g/person as the median. The dose-response relationship between methanol vapor in ambient air and urinary methanol concentrations was thought to be correlated. An oral intake of 3.16-11.85 g/person of pure methanol could cause blindness. The lethal dose from respiratory intake was reported to be 4000-13,000 mg/l. The initial concentration of optic neuritis and blindness were shown to be 228.5 and 1103 mg/l, respectively, for a 12-h exposure. The concentration of biological exposure indices and clinical symptoms for methanol exposure might have a dose-response relationship according to previous articles. Even a low dose of pure methanol through oral or respiratory exposure might be lethal or result in blindness as a clinical symptom.

  18. Beneficial effects of low dose Musa paradisiaca on the semen quality of male Wistar rats.

    PubMed

    Alabi, A S; Omotoso, Gabriel O; Enaibe, B U; Akinola, O B; Tagoe, C N B

    2013-03-01

    This study aimed at determining the effects of administration of mature green fruits of Musa paradisiaca on the semen quality of adult male Wistar rats. THE ANIMALS USED FOR THE STUDY WERE GROUPED INTO THREE: the control group, given 2 ml of double distilled water, a low dose group given 500 mg/kg/day and a high dose group given 1000 mg/kg/day of the plantain fruits, which was made into flour, and dissolved in 2 ml of double distilled water for easy oral administration. Significant increment in the semen parameters was noticed in animals that received a lower dose of the plantain flour, but those animals who received the high dose had marked and very significant reduction in sperm cell concentration and percentage of morphologically normal spermatozoa. Musa paradisiaca should be consumed in moderate quantities in order to derive its beneficial effects of enhancing male reproductive functions.

  19. Understanding why an active video game intervention did not improve motor skill and physical activity in children with developmental coordination disorder: A quantity or quality issue?

    PubMed

    Howie, Erin K; Campbell, Amity C; Abbott, Rebecca A; Straker, Leon M

    2017-01-01

    Active video games (AVGs) have been identified as a novel strategy to improve motor skill and physical activity in clinical populations. A recent cross-over randomized trial found AVGs to be ineffective at improving motor skill and physical activity in the home-environment for children with or at-risk for developmental coordination disorder (DCD). The study purpose was to better understand why the intervention had been ineffective by examining the quantity and quality of AVG play during an AVG intervention for children with or at-risk for DCD. Participants (n=21, ages 9-12) completed the 16 week AVG intervention. Detailed quantitative and qualitative data were systematically triangulated to obtain the quantity of exposure (AVG exposure over time, patterns of exposure) and quality of use (game selection, facilitators and barriers to play). The median AVG dose (range 30-35min/day) remained relatively stable across the intervention and met the prescribed dose. Play quality was impacted by game selection, difficulty playing games, lack of time, illness, technical difficulties and boredom. The ineffectiveness of a home-based AVG intervention may be due to quality of play. Strategies to improve the quality of game play may help realize the potential benefits of AVGs as a clinical tool for children with DCD. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Mutant quantity and quality in mammalian cells (AL) exposed to cesium-137 gamma radiation: effect of caffeine

    NASA Technical Reports Server (NTRS)

    McGuinness, S. M.; Shibuya, M. L.; Ueno, A. M.; Vannais, D. B.; Waldren, C. A.; Chatterjee, A. (Principal Investigator)

    1995-01-01

    We examined the effect of caffeine (1,3,7-trimethylxanthine) on the quantity and quality of mutations in cultured mammalian AL human-hamster hybrid cells exposed to 137Cs gamma radiation. At a dose (1.5 mg/ml for 16 h) that reduced the plating efficiency (PE) by 20%, caffeine was not itself a significant mutagen, but it increased by approximately twofold the slope of the dose-response curve for induction of S1- mutants by 137Cs gamma radiation. Molecular analysis of 235 S1- mutants using a series of DNA probes mapped to the human chromosome 11 in the AL hybrid cells revealed that 73 to 85% of the mutations in unexposed cells and in cells treated with caffeine alone, 137Cs gamma rays alone or 137Cs gamma rays plus caffeine were large deletions involving millions of base pairs of DNA. Most of these deletions were contiguous with the region of the MIC1 gene at 11p13 that encodes the S1 cell surface antigen. In other mutants that had suffered multiple marker loss, the deletions were intermittent along chromosome 11. These "complex" mutations were rare for 137Cs gamma irradiation (1/63 = 1.5%) but relatively prevalent (23-50%) for other exposure conditions. Thus caffeine appears to alter both the quantity and quality of mutations induced by 137Cs gamma irradiation.

  1. 33 CFR 183.105 - Quantity of flotation required.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... of the dead weight; and (3) A weight in pounds that, when submerged, equals 62.4 times the volume in... of this section, “dead weight” means the maximum weight capacity marked on the boat minus the persons...

  2. 33 CFR 183.105 - Quantity of flotation required.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... of the dead weight; and (3) A weight in pounds that, when submerged, equals 62.4 times the volume in... of this section, “dead weight” means the maximum weight capacity marked on the boat minus the persons...

  3. 33 CFR 183.105 - Quantity of flotation required.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... of the dead weight; and (3) A weight in pounds that, when submerged, equals 62.4 times the volume in... of this section, “dead weight” means the maximum weight capacity marked on the boat minus the persons...

  4. 33 CFR 183.105 - Quantity of flotation required.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... of the dead weight; and (3) A weight in pounds that, when submerged, equals 62.4 times the volume in... of this section, “dead weight” means the maximum weight capacity marked on the boat minus the persons...

  5. 33 CFR 183.105 - Quantity of flotation required.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... of the dead weight; and (3) A weight in pounds that, when submerged, equals 62.4 times the volume in... of this section, “dead weight” means the maximum weight capacity marked on the boat minus the persons...

  6. Occupational Exposure of the Eye Lens in Interventional Procedures: How to Assess and Manage Radiation Dose.

    PubMed

    Ciraj-Bjelac, Olivera; Carinou, Eleftheria; Ferrari, Paolo; Gingaume, Merce; Merce, Marta Sans; O'Connor, Una

    2016-11-01

    Occupational exposure from interventional x-ray procedures is one of the areas in which increased eye lens exposure may occur. Accurate dosimetry is an important element to investigate the correlation of observed radiation effects with radiation dose, to verify the compliance with regulatory dose limits, and to optimize radiation protection practice. The objective of this work is to review eye lens dose levels in clinical practice that may occur from the use of ionizing radiation. The use of a dedicated eye lens dosimeter is the recommended methodology; however, in practice it cannot always be easily implemented. Alternatively, the eye lens dose could be assessed from measurements of other dosimetric quantities or other indirect parameters, such as patient dose. The practical implementation of monitoring eye lens doses and the use of adequate protective equipment still remains a challenge. The use of lead glasses with a good fit to the face, appropriate lateral coverage, and/or ceiling-suspended screens is recommended in workplaces with potential high eye lens doses. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  7. Computation of mean and variance of the radiotherapy dose for PCA-modeled random shape and position variations of the target.

    PubMed

    Budiarto, E; Keijzer, M; Storchi, P R M; Heemink, A W; Breedveld, S; Heijmen, B J M

    2014-01-20

    Radiotherapy dose delivery in the tumor and surrounding healthy tissues is affected by movements and deformations of the corresponding organs between fractions. The random variations may be characterized by non-rigid, anisotropic principal component analysis (PCA) modes. In this article new dynamic dose deposition matrices, based on established PCA modes, are introduced as a tool to evaluate the mean and the variance of the dose at each target point resulting from any given set of fluence profiles. The method is tested for a simple cubic geometry and for a prostate case. The movements spread out the distributions of the mean dose and cause the variance of the dose to be highest near the edges of the beams. The non-rigidity and anisotropy of the movements are reflected in both quantities. The dynamic dose deposition matrices facilitate the inclusion of the mean and the variance of the dose in the existing fluence-profile optimizer for radiotherapy planning, to ensure robust plans with respect to the movements.

  8. Radiation dose- and sex-dependent cardiovascular mortality in residents of contaminated areas after the Chornobyl NPP accident, 1988-2010 observation period.

    PubMed

    Buzunov, V O; Prikaschikova, K Ye; Gubina, I G; Kostiuk, G V; Tereschenko, S O

    2013-01-01

    To estimate the circulatory system disease death rates for people living in areas contaminated after the Chornobyl accident. Epidemiological estimation covered the post-accident period (1988-2010) and was focused on the relationship between death rates and doses accumulated over 1986-2010 or sex of survivors aged under 60 at the time of the accident. We used data from the State Registry of Ukraine on persons affected by the Chornobyl accident. Residents of contaminated areas were grouped into the two cohorts according to cumulative dose values. Cohort 1 numbered 155,592 people (86,787 females and 68,805 males), their radiation doses were 5.6-20.99 mSv; cohort 2 totaled 98,830 people (52,640 females and 46,190 males) with radiation doses 21.00-50.99 mSv. Mean age (X ± δ) of inhabitants of contaminated areas at the time of the accident (April 26, 1986) was 29.5 ± 23.2 years (30.6 ± 22.3 for women and 28.3 ± 23.2 for men) in the cohort 1, and 28.7 ± 17.3 years (29.8 ± 17.7 and 27.5 ± 16.2 respectively) in the cohort 2). These cohorts were subdivided by sex (males and females). Significantly higher (ID per 103 person-years is 8.08 ± 0.10) cardiovascular mortality was revealed among members of the cohort 2 vs. cohort 1 (ID per 103 person-years is 6.29 ± 0.06). Mortality from cardiovascular diseases in both sex groups of the cohort 2 is higher (ID per 103 person-years is 6.80 ± 0.12 in women and 9.43 ± 0.15 - in men) than that of the cohort 1 (ID per 103 person-years is 5.34 ± 0.08 in women, 7.37 ± 0.10 - in men). Whatever accumulated doses the mortality from circulatory diseases was significantly higher in men vs. women. Cardiovascular mortality in population of radiation-contaminated territories depends on the integral radiation exposure and gender. Death rates are clearly higher (p<0.05) in persons having more radiation doses vs. those exposed to less ones. Mortality is significantly higher in males vs. females despite integral radiation doses values. The coronary heart disease, cerebrovascular disease, arterial hypertension, heart diseases, diseases of arteries, arterioles and capillaries) were the main causes of death. Buzunov V. O., Prykashhykova K. Je., Gubina I. G., Kostjuk G. V., Tereshhenko S. O., 2013.

  9. CIE, Vitamin D and DNA Damage: A Synergetic Study in Thessaloniki, Greece

    NASA Astrophysics Data System (ADS)

    Zempila, Melina Maria; Taylor, Michael; Fountoulakis, Ilias; Koukouli, Maria Elissavet; Bais, Alkiviadis; Arola, Antii; van Geffen, Jos; van Weele, Michiel; van der A, Ronald; Kouremeti, Natalia; Kazadzis, Stelios; Meleti, Chariklia; Balis, Dimitrios

    2016-08-01

    The present study aims to validate different approaches for the estimation of three photobiological effective doses: the erythemal UV, the vitamin D and that for DNA damage, using high temporal resolution surface- based measurements of solar UV from 2005-2015. Data from a UV spectrophotometer, a multi-filter radiometer, and a UV radiation pyranometer that are located in Thessaloniki, Greece are used together with empirical relations, algorithms and models in order to calculate the desired quantities. In addition to the surface-based dose retrievals, OMI/Aura and the combined SCIAMACHY/Envisat and GOME/MetopA satellite products are also used in order to assess the accuracy of each method for deriving the photobiological doses.

  10. Individual dose reconstruction among residents living in the vicinity of the Semipalatinsk nuclear test site using EPR spectroscopy of tooth enamel.

    PubMed

    Ivannikov, A I; Zhumadilov, Zh; Gusev, B I; Miyazawa, Ch; Jiao, L; Skvortsov, V G; Stepanenko, V F; Takada, J; Hoshi, M

    2002-08-01

    Individual accumulated doses were determined by EPR spectroscopy of tooth enamel for 26 adult persons residing in territories adjacent to the Semipalatinsk Nuclear Test Site (SNTS). The absorbed dose values due to radiation from nuclear tests were obtained after subtracting the contribution of natural background radiation from the total accumulated dose. The determined dose values ranged up to 250 mGy, except for one person from Semipalatinsk city with a measured dose of 2.8 +/- 0.4 Gy. Increased dose values were determined for the individuals whose teeth were formed before 1962, the end of the atmospheric nuclear tests. These values were found to be significantly larger than those obtained for a group of younger residents of heavily exposed territories and the residents of territories not exposed to radioactive fallout. These increased dose values are consistent with those based on officially registered data for the Northeastern part of Kazakstan adjacent to SNTS, which was exposed to high levels of radioactive fallout from nuclear tests in period 1949-1962.

  11. Assessment of radiation doses from residential smoke detectors that contain americium-241

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Donnell, F.R.; Etnier, E.L.; Holton, G.A.

    1981-10-01

    External dose equivalents and internal dose commitments were estimated for individuals and populations from annual distribution, use, and disposal of 10 million ionization chamber smoke detectors that contain 110 kBq (3 ..mu..Ci) americium-241 each. Under exposure scenarios developed for normal distribution, use, and disposal using the best available information, annual external dose equivalents to average individuals were estimated to range from 4 fSv (0.4 prem) to 20 nSv (2 ..mu..rem) for total body and from 7 fSv to 40 nSv for bone. Internal dose commitments to individuals under post disposal scenarios were estimated to range from 0.006 to 80 ..mu..Svmore » (0.0006 to 8 mrem) to total body and from 0.06 to 800 ..mu..Sv to bone. The total collective dose (the sum of external dose equivalents and 50-year internal dose commitments) for all individuals involved with distribution, use, or disposal of 10 million smoke detectors was estimated to be about 0.38 person-Sv (38 person-rem) to total body and 00 ft/sup 2/).« less

  12. ABSORPTION, DISTRIBUTION AND MILK SECRETION OF RADIONUCLIDES BY THE DAIRY COW - V. RADIOTUNGSTEN

    EPA Science Inventory

    In a study conducted in 1969 and 1970 lactating cows were given oral or intravenous (I.V.) doses of radiotungsten. Blood, milk, urine and feces were collected and analyzed to measure transfer rate and quantity of tungsten eliminated over an extended period during and after exposu...

  13. [Surgery of the breast on transgender persons].

    PubMed

    Karhunen-Enckell, Ulla; Kolehmainen, Maija; Kääriäinen, Minna; Suominen, Sinikka

    2015-01-01

    For a female-to-male transgender person, mastectomy is the most important procedure making the social interaction easier. Along with the size of the breasts, the quantity and quality of skin will influence the selection of surgical technique. Although complications are rare, corrective surgery is performed for as many as 40% of the patients. Of male-to-female transsexual persons, 60 to 70% opt for breast enlargement. Breast enlargement can be carried out by using either silicone implants or fat transplantation. Since the surgical procedures on breasts are irreversible, their implementation requires confirmation of the diagnosis of transsexualism by a multidisciplinary team.

  14. Food irradiation dosimetry by opti-chromic technique

    NASA Astrophysics Data System (ADS)

    Zhan-Jun, Liu; Radak, B. B.; McLaughlin, W. L.

    The measurement of gamma-radiation quantities, e.g., absorbed dose in materials such as water, plastics, foodstuffs, is a convenient means of quality assurance in radiation processing. A new dosimetry system, called the "Opti-Chromic" dosimeter, is commercially available in large batches for use as a routine measurement system in the absorbed dose range 10 to 2x10 4 Gy. This dose range covers most food irradiation applications. A statistical evaluation was made of the reproducibility of this dosimeter for measuring doses appropriate for the disinfestation and shelf-life extension of many foods, namely 10 to 2x10 3 Gy. In addition, the small dosimeters were used to map absorbed dose distributions in boxes of foods having four different bulk densities (grapefruit, lemons, peanuts, and wheat bran). It is demonstrated that the dosimeters are rugged and stable enough to be used over a wide temperature and humidity range, and, in fact, can be placed in such environments as the inside of citrus fruits without adverse effects on their ability to give satisfactory dose assessment.

  15. [Effect of a glutamate and glutamine excess on the nucleic acid content of the spleen cell nuclei in rats].

    PubMed

    Vorontsova, E N; Okunev, V N

    1976-01-01

    In tests conducted with albino rats subject to investigation was the effect of sodium glutamate, or glutamine, daily introduced into the stomach in doses of 300 and 150 mg/kg, on the nucleic acids content in the splenic cell nuclei. All the animals taken in the experiment demonstrated a clearcut quantity of nucleonic RNA. By using a maximum dose of sodium glutamate and minimal one of glutamine a rise in the amount of DNA occurs in the nuclei of the splenic cells.

  16. Depression and anger in fathers of unsettled infants: A community cohort study.

    PubMed

    Cook, Fallon; Giallo, Rebecca; Petrovic, Zvezdana; Coe, Amy; Seymour, Monique; Cann, Warren; Hiscock, Harriet

    2017-02-01

    To examine the relationship between unsettled infant behaviour and fathers' depressive symptoms, cognitions surrounding infant sleep (anger, doubt), and personal sleep, in a community cohort. Data were collected from 102 fathers of healthy infants at 4 weeks, 4 months and 6 months of age. Measures included father report of infant sleep and crying problems, depressive symptoms, cognitions about infant sleep and own sleep quality and quantity. Data were analysed using adjusted regression models. Sleep problems at 4 months of age were associated with increased depressive symptoms (adjusted mean difference 2.64 (1.27-4.00)), doubt (adjusted mean difference 1.82 (0.40-3.25)), anger (adjusted mean difference 1.86 (0.51-3.20)), poor personal sleep quantity (adjusted odds ratio (OR) 0.21; 95% confidence interval (CI) 0.09-0.51) and quality (adjusted OR 0.20; 95% CI 0.08-0.51); and at 6 months of age, with increased depressive symptoms (adjusted mean difference 2.56 (1.28-3.84)), anger (adjusted mean difference 1.63 (0.40-2.87)), poor personal sleep quantity (adjusted OR 0.14; 95% CI 0.05-0.38) and quality (adjusted OR 0.28; 95% CI 0.11-0.72). Infant cry problems at 4 months were associated with increased anger (adjusted mean difference 1.98 (0.60-3.36)) and doubt (adjusted mean difference 1.55 (0.05-3.05)); and at 6 months, with increased depressive symptoms (adjusted mean difference 3.04 (1.59-4.69)), anger (adjusted mean difference 2.73 (1.29-4.17)) and less personal sleep (adjusted OR 0.22; 95% CI 0.07-0.71). Fathers of unsettled infants reported greater anger towards their infant and increased depressive symptoms by 4 months infant age, with these symptoms persisting 2 months later. Evidence-based interventions are needed for these fathers. © 2016 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  17. Calculation of the nuclear material inventory in a sealed vault by 3D radiation mapping

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adsley, Ian; Klepikov, Alexander; Tur, Yevgeniy

    2013-07-01

    The paper relates to the determination of the amount of nuclear material contained in a closed, concrete lined vault at the Aktau fast breeder reactor in Kazakhstan. This material had been disposed into the vault after examination in an experimental hot cell directly above the vault. In order to comply with IAEA Safeguards requirements it was necessary to determine the total quantities of nuclear materials - enriched uranium and plutonium - that were held with Kazakhstan. Although it was possible to determine the inventory of all of the accessible nuclear material - the quantity remaining in the vault was unknown.more » As part of the Global Threat Reduction Programme the UK Government funded a project to determine the inventory of these nuclear materials in this vault. This involved drilling three penetrations through the concrete lined roof of the vault; this enabled the placement of lights and a camera into the vault through two penetrations; while the third penetration enabled a lightweight manipulator arm to be introduced into the vault. This was used to provide a detailed 3D mapping of the dose rate within the vault and it also enabled the collection of samples for radionuclide analysis. The deconvolution of the 3D dose rate profile within the vault enabled the determination of the gamma emitting source distribution on the floor and walls of the vault. The samples were analysed to determine the fingerprint of those radionuclides producing the gamma dose - namely {sup 137}Cs and {sup 60}Co - to the nuclear materials. The combination of the dose rate source terms on the surfaces of the vault and the fingerprint then enabled the quantities of nuclear materials to be determined. The project was a major success and enabled the Kazakhstan Government to comply with IAEA Safeguards requirements. It also enabled the UK DECC Ministry to develop a technology of national (and international) use. Finally the technology was well received by IAEA Safeguards as an acceptable methodology for future studies. (authors)« less

  18. The leaded apron revisited: does it reduce gonadal radiation dose in dental radiology?

    PubMed

    Wood, R E; Harris, A M; van der Merwe, E J; Nortjé, C J

    1991-05-01

    A tissue-equivalent anthropomorphic human phantom was used with a lithium fluoride thermoluminescent dosimetry system to evaluate the radiation absorbed dose to the ovarian and testicular region during dental radiologic procedures. Measurements were made with and without personal lead shielding devices consisting of thyroid collar and apron of 0.25 mm lead thickness equivalence. The radiation absorbed dose with or without lead shielding did not differ significantly from control dosimeters in vertex occlusal and periapical views (p greater than 0.05). Personal lead shielding devices did reduce gonadal dose in the case of accidental exposure (p less than 0.05). A leaded apron of 0.25 mm lead thickness equivalent was permeable to radiation in direct exposure testing.

  19. 7 CFR 966.134 - Reports.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... and Orders; Fruits, Vegetables, Nuts), DEPARTMENT OF AGRICULTURE TOMATOES GROWN IN FLORIDA Rules and Regulations Exemption Procedures § 966.134 Reports. Persons handling tomatoes under exemption certificates... and addresses of the receivers of such tomatoes, the quantity shipped (by grade, size, quality, and...

  20. 44 CFR 62.20 - Claims appeals.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (includes contractors' estimates), detailing unit cost and quantities for the items needing repair or replacement; replacement cost proofs of loss; Preliminary Report; Final Report; detailed damaged personal... wind policies and any claim information submitted to the other companies; Waiver, Letter of Map...

  1. 44 CFR 62.20 - Claims appeals.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (includes contractors' estimates), detailing unit cost and quantities for the items needing repair or replacement; replacement cost proofs of loss; Preliminary Report; Final Report; detailed damaged personal... wind policies and any claim information submitted to the other companies; Waiver, Letter of Map...

  2. A Randomized Controlled Trial Testing the Efficacy of a Brief Online Alcohol Intervention for High School Seniors.

    PubMed

    Doumas, Diana M; Esp, Susan; Flay, Brian; Bond, Laura

    2017-09-01

    The purpose of this randomized controlled study was to examine the efficacy of a brief, web-based personalized feedback intervention (the eCHECKUP TO GO) on alcohol use and alcohol-related consequences among high school seniors. Participants (n = 221) were high school seniors randomized by class period to either a brief, web-based personalized feedback intervention (the eCHECKUP TO GO) or an assessment-only control group. Participants completed online surveys at baseline and at a 6-week follow-up. Students participating in the eCHECKUP TO GO intervention reported a significant reduction in weekly drinking quantity, peak drinking quantity, and frequency of drinking to intoxication relative to those in the control group. Intervention effects were moderated by high-risk status (one or more episodes of heavy episodic drinking in the past 2 weeks reported at baseline) such that intervention effects were significant for high-risk students only. Results for alcohol-related consequences were not significant. Providing a brief, web-based personalized feedback intervention in the school setting is a promising approach for reducing problem alcohol use among high school seniors who report recent heavy episodic drinking.

  3. Cancer risk estimation caused by radiation exposure during endovascular procedure

    NASA Astrophysics Data System (ADS)

    Kang, Y. H.; Cho, J. H.; Yun, W. S.; Park, K. H.; Kim, H. G.; Kwon, S. M.

    2014-05-01

    The objective of this study was to identify the radiation exposure dose of patients, as well as staff caused by fluoroscopy for C-arm-assisted vascular surgical operation and to estimate carcinogenic risk due to such exposure dose. The study was conducted in 71 patients (53 men and 18 women) who had undergone vascular surgical intervention at the division of vascular surgery in the University Hospital from November of 2011 to April of 2012. It had used a mobile C-arm device and calculated the radiation exposure dose of patient (dose-area product, DAP). Effective dose was measured by attaching optically stimulated luminescence on the radiation protectors of staff who participates in the surgery to measure the radiation exposure dose of staff during the vascular surgical operation. From the study results, DAP value of patients was 308.7 Gy cm2 in average, and the maximum value was 3085 Gy cm2. When converted to the effective dose, the resulted mean was 6.2 m Gy and the maximum effective dose was 61.7 milliSievert (mSv). The effective dose of staff was 3.85 mSv; while the radiation technician was 1.04 mSv, the nurse was 1.31 mSv. All cancer incidences of operator are corresponding to 2355 persons per 100,000 persons, which deemed 1 of 42 persons is likely to have all cancer incidences. In conclusion, the vascular surgeons should keep the radiation protection for patient, staff, and all participants in the intervention in mind as supervisor of fluoroscopy while trying to understand the effects by radiation by themselves to prevent invisible danger during the intervention and to minimize the harm.

  4. Measles, mumps, and rubella--vaccine use and strategies for elimination of measles, rubella, and congenital rubella syndrome and control of mumps: recommendations of the Advisory Committee on Immunization Practices (ACIP).

    PubMed

    Watson, J C; Hadler, S C; Dykewicz, C A; Reef, S; Phillips, L

    1998-05-22

    These revised recommendations of the Advisory Committee on Immunization Practices (ACIP) on measles, mumps, and rubella prevention supersede recommendations published in 1989 and 1990. This statement summarizes the goals and current strategies for measles, rubella, and congenital rubella syndrome (CRS) elimination and for mumps reduction in the United States. Changes from previous recommendations include: Emphasis on the use of combined MMR vaccine for most indications; A change in the recommended age for routine vaccination to 12-15 months for the first dose of MMR, and to 4-6 years for the second dose of MMR; A recommendation that all states take immediate steps to implement a two dose MMR requirement for school entry and any additional measures needed to ensure that all school-aged children are vaccinated with two doses of MMR by 2001; A clarification of the role of serologic screening to determine immunity; A change in the criteria for determining acceptable evidence of rubella immunity; A recommendation that all persons who work in health-care facilities have acceptable evidence of measles and rubella immunity; Changes in the recommended interval between administration of immune globulin and measles vaccination; and Updated information on adverse events and contraindications, particularly for persons with severe HIV infection, persons with a history of egg allergy or gelatin allergy, persons with a history of thrombocytopenia, and persons receiving steroid therapy.

  5. A Biodosimeter for Multiparametric Determination of Radiation Dose, Radiation Quality, and Radiation Risk

    NASA Technical Reports Server (NTRS)

    Richmond, Robert; Cruz, Angela; Jansen, Heather; Bors, Karen

    2003-01-01

    Predicting risk of human cancer following exposure of an individual or a population to ionizing radiation is challenging. To an approximation, this is because uncertainties of uniform absorption of dose and the uniform processing of dose-related damage at the cellular level within a complex set of biological variables degrade the confidence of predicting the delayed expression of cancer as a relatively rare event. Cellular biodosimeters that simultaneously report: 1) the quantity of absorbed dose after exposure to ionizing radiation, 2) the quality of radiation delivering that dose, and 3) the risk of developing cancer by the cells absorbing that dose would therefore be useful. An approach to such a multiparametric biodosimeter will be reported. This is the demonstration of a dose responsive field effect of enhanced expression of keratin 18 (K18) in cultures of human mammary epithelial cells irradiated with cesium-1 37 gamma-rays. Dose response of enhanced K18 expression was experimentally extended over a range of 30 to 90 cGy for cells evaluated at mid-log phase. K18 has been reported to be a marker for tumor staging and for apoptosis, and thereby serves as an example of a potential marker for cancer risk, where the reality of such predictive value would require additional experimental development. Since observed radiogenic increase in expression of K18 is a field effect, ie., chronically present in all cells of the irradiated population, it may be hypothesized that K18 expression in specific cells absorbing particulate irradiation, such as the high-LET-producing atomic nuclei of space radiation, will report on both the single-cell distributions of those particles amongst cells within the exposed population, and that the relatively high dose per cell delivered by densely ionizing tracks of those intersecting particles will lead to cell-specific high-expression levels of K18, thereby providing analytical end points that may be used to resolve both the quantity and the quality of the radiation dose absorbed by individual cells. The principal value of this reported potential multiparametric cellular biodosimeter is suggested to be that it justifies a search for similar but more robust radiogenic assays. That is, K18 is only one radiation dose-sensitive expressed protein, whereas analytical techniques of genomics and proteomics can be used to simultaneously analyze multiple gene and protein expressions resulting from radiation-dose absorption. The potential usefulness of multiparametric cellular biodosimeters will be best realized from quantitatively profiling these multiple markers using these modern techniques.

  6. Personalized technologist dose audit feedback for reducing patient radiation exposure from CT.

    PubMed

    Miglioretti, Diana L; Zhang, Yue; Johnson, Eric; Lee, Choonsik; Morin, Richard L; Vanneman, Nicholas; Smith-Bindman, Rebecca

    2014-03-01

    The aim of this study was to determine whether providing radiologic technologists with audit feedback on doses from CT examinations they conduct and education on dose-reduction strategies reduces patients' radiation exposure. This prospective, controlled pilot study was conducted within an integrated health care system from November 2010 to October 2011. Ten technologists at 2 facilities received personalized dose audit reports and education on dose-reduction strategies; 9 technologists at a control facility received no intervention. Radiation exposure was measured by the dose-length product (DLP) from CT scans performed before (n = 1,630) and after (n = 1,499) the intervention and compared using quantile regression. Technologists were surveyed before and after the intervention. For abdominal CT, DLPs decreased by 3% to 12% at intervention facilities but not at the control facility. For brain CT, DLPs significantly decreased by 7% to 12% at one intervention facility; did not change at the second intervention facility, which had the lowest preintervention DLPs; and increased at the control facility. Technologists were more likely to report always thinking about radiation exposure and associated cancer risk and optimizing settings to reduce exposure after the intervention. Personalized audit feedback and education can change technologists' attitudes about, and awareness of, radiation and can lower patient radiation exposure from CT imaging. Copyright © 2014 American College of Radiology. All rights reserved.

  7. Biodosimetry of Persons Chronically Exposed to Low and Therapeutic Doses of Ionizing Radiation

    PubMed Central

    Zedginidze, Alla; Namchevadze, Ema; Ormocadze, George; Kapanadze, Archil; Nikuradze, Tamara; Lomidze, Darejan

    2016-01-01

    Dynamic changes of the chromosomal aberrations and the DNA damage were analyzed in individuals exposed to low and therapeutic doses of radiation. The investigation included 37 persons living in areas where the radioactive sources were discovered 10–12 years ago. It was established by biodosimetry methods that the examined persons had absorbed dose of 0.2–0.7 Gy or had increased number of chromosomal aberrations, though insufficient to determine a dose. Clinical examination, chromosomal analysis, and assay of DNA damage by the comet (single-cell gel electrophoresis) assay were carried out. There was no correlation between the doses received 10 years ago and the cytogenetic changes with clinical outcome. The effect of the local fractionated gamma-irradiation with doses of 40–70 Gy was studied in cancer patients with localized head and neck tumors. The study of chromosomal abnormalities, the DNA damages by the comet assay, and the micronuclei detection of the buccal cells revealed a statistically significant correlation between the initial cytogenetic indices in cancer patients and their dynamic changes during and after the radiation exposure. In addition, the correlation was detected between the initial cytogenetic parameters and the functional stage of red blood system. Our results allow us to conclude that there is a need for further research to estimate the individual radiation risk to optimize and individualize the subsequent medical management of radiotherapy. PMID:28217288

  8. Biodosimetry of Persons Chronically Exposed to Low and Therapeutic Doses of Ionizing Radiation.

    PubMed

    Zedginidze, Alla; Namchevadze, Ema; Ormocadze, George; Kapanadze, Archil; Nikuradze, Tamara; Lomidze, Darejan

    2016-01-01

    Dynamic changes of the chromosomal aberrations and the DNA damage were analyzed in individuals exposed to low and therapeutic doses of radiation. The investigation included 37 persons living in areas where the radioactive sources were discovered 10-12 years ago. It was established by biodosimetry methods that the examined persons had absorbed dose of 0.2-0.7 Gy or had increased number of chromosomal aberrations, though insufficient to determine a dose. Clinical examination, chromosomal analysis, and assay of DNA damage by the comet (single-cell gel electrophoresis) assay were carried out. There was no correlation between the doses received 10 years ago and the cytogenetic changes with clinical outcome. The effect of the local fractionated gamma-irradiation with doses of 40-70 Gy was studied in cancer patients with localized head and neck tumors. The study of chromosomal abnormalities, the DNA damages by the comet assay, and the micronuclei detection of the buccal cells revealed a statistically significant correlation between the initial cytogenetic indices in cancer patients and their dynamic changes during and after the radiation exposure. In addition, the correlation was detected between the initial cytogenetic parameters and the functional stage of red blood system. Our results allow us to conclude that there is a need for further research to estimate the individual radiation risk to optimize and individualize the subsequent medical management of radiotherapy.

  9. Principles of self-adjustment of insulin dose in people with diabetes type 2 and flexible insulin therapy.

    PubMed

    Kramer, G; Kuniss, N; Kloos, C; Lehmann, T; Müller, N; Sanow, B; Lorkowski, S; Wolf, G; Müller, U A

    2016-06-01

    Structured treatment and education programmes for people with type 2 diabetes mellitus (T2DM) and flexible insulin therapy provide rules for self-adjustment of insulin dose, that are extensively trained. The aim of this cohort study was to register current principles and the frequency of self-adjustment of insulin dose and their association with metabolic control in people with T2DM. Details of insulin dose adjustment were assessed by a structured interview in 149 people with T2DM on flexible insulin therapy (mean HbA1c 7.1%/53.8mmol/mol, age 65y, diabetes duration 19.0y, BMI 33.8kg/m(2)) in a tertiary care centre. The frequency of insulin dose adjustments was obtained from the last 28days of the patients' diaries. Insulin dose adjustment by adjustment rules was used by 33 people (22.1%) and by personal experience/feeling in 111 participants (74.5%). People adjusting by rules were younger (60.9±9.8 vs. 65.7±9.2, p=0.011) and did more insulin dose adjustments per 28days (50.0±31.0 vs. 33.4±23.5, p=0.016). HbA1c and incidence of hypoglycaemia were comparable. There were no differences in satisfaction of treatment, quality of life as well as current well-being between the groups. Only a fifth of the participants used the rule trained within the education programme to adjust their insulin dose. The majority adjusted their insulin dose by personal experience/feeling. However, people in both groups were able to adjust their insulin dose. Although people using adjustment rules adjust their insulin dose more frequently, HbA1c and the incidence of hypoglycaemia was similar compared to those using personal experience/feeling. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. 75 FR 25127 - Operations Specifications

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-07

    ... information on those who are to respond, including by using appropriate automated, electronic, mechanical, or... total quantity of hydraulic fluid. Flag operation means any scheduled operation conducted by any person... aircraft equipment, and less the operating load (consisting of minimum flightcrew, foods and beverages, and...

  11. Template for Annual Report for a Person Exporting Cathode Ray Tubes (CRTs) for Recycling

    EPA Pesticide Factsheets

    CRT exporters must file with EPA no later than March 1 of each year, an annual report summarizing the quantities, frequency of shipment, and ultimate destination(s) of all used CRTs exported during the previous calendar year.

  12. 40 CFR 82.18 - Availability of production in addition to baseline production allowances for class II controlled...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... permitted under the Montreal Protocol or to receive from the person for the current control period some... production quantities: (A) The maximum production that the nation is allowed under the Protocol minus the...

  13. Evaluation of the 2-(1-Hexyloxyethyl)-2-devinyl pyropheophorbide (HPPH) mediated photodynamic therapy by macroscopic singlet oxygen modeling.

    PubMed

    Penjweini, Rozhin; Kim, Michele M; Liu, Baochang; Zhu, Timothy C

    2016-12-01

    Photodynamic therapy (PDT) is known as a non-invasive treatment modality that is based on photochemical reactions between oxygen, photosensitizer, and a special wavelength of light. However, a dosimetric predictor for PDT outcome is still elusive because current dosimetric quantities do not account for the differences in the PDT oxygen consumption rate for different fluence rates. In this study, we evaluate several dose metrics, total fluence, photobleaching ratio, PDT dose, and mean reacted singlet oxygen (mean [ 1 O 2 ] rx ) for predicting the PDT outcome and a clinically relevant tumor re-growth endpoint. For this reason, radiation-induced fibrosarcoma (RIF) mice tumors are treated with 2-(1-Hexyloxyethyl)-2-devinyl pyropheophorbide (HPPH) and different in-air fluences (30 J/cm 2 , 50 J/cm 2 , 135 J/cm 2 , 250 J/cm 2 , and 350 J/cm 2 ) and in-air fluence rates (20, 50, 75, 150 mW/cm 2 ). Explicit measurements of HPPH and oxygen concentration as well as tissue optical properties are performed pre- and post-treatment. Then, this information is incorporated into a macroscopic model to calculate the photobleaching, PDT dose, and mean [ 1 O 2 ] rx . Changes in tumor volume are tracked following the treatment and compared with the dose metrics. The correlation demonstrates that mean [ 1 O 2 ] rx  serves as a better dosimetric quantity for predicting treatment outcome and a clinically relevant tumor re-growth endpoint. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. A shot in the rear, not a shot in the dark: application of a mass clinic framework in a public health emergency.

    PubMed

    Erwin, Paul Campbell; Sheeler, Lorinda; Lott, John M

    2009-01-01

    An outbreak of foodborne hepatitis A infection compelled two regional health departments in eastern Tennessee to implement an emergency mass clinic for providing hepatitis immune serum globulin (ISG) to several thousand potentially exposed people. For the mass clinic framework, we utilized the smallpox post-event clinic plans of the Centers for Disease Control and Prevention (CDC), although the plans had only been exercised for smallpox. Following CDC's guidelines for staffing and organizing the mass clinic, we provided 5,038 doses of ISG during a total of 24 hours of clinic operation, using 3,467 person-hours, or 1.45 ISG doses per person-hour-very close to the 1.58 doses per person-hour targeted in CDC's smallpox post-event clinic plans. The mass clinic showed that CDC's smallpox post-event clinic guidelines were feasible, practical, and adaptable to other mass clinic situations.

  15. STABILITY OF THE NEUTRON DOSE DETERMINATION ALGORITHM FOR PERSONAL NEUTRON DOSEMETERS AT DIFFERENT RADON GAS EXPOSURES.

    PubMed

    Mayer, Sabine; Boschung, Markus; Butterweck, Gernot; Assenmacher, Frank; Hohmann, Eike

    2016-09-01

    Since 2008 the Paul Scherrer Institute (PSI) has been using a microscope-based automatic scanning system for assessing personal neutron doses with a dosemeter based on PADC. This scanning system, known as TASLImage, includes a comprehensive characterisation of tracks. The distributions of several specific track characteristics such as size, shape and optical density are compared with a reference set to discriminate tracks of alpha particles and non-track background. Due to the dosemeter design at PSI, it is anticipated that radon should not significantly contribute to the creation of additional tracks in the PADC detector. The present study tests the stability of the neutron dose determination algorithm of the personal neutron dosemeter system in operation at PSI at different radon gas exposures. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Soft, stretchable, epidermal sensor with integrated electronics and photochemistry for measuring personal UV exposures.

    PubMed

    Shi, Yunzhou; Manco, Megan; Moyal, Dominique; Huppert, Gil; Araki, Hitoshi; Banks, Anthony; Joshi, Hemant; McKenzie, Richard; Seewald, Alex; Griffin, Guy; Sen-Gupta, Ellora; Wright, Donald; Bastien, Philippe; Valceschini, Florent; Seité, Sophie; Wright, John A; Ghaffari, Roozbeh; Rogers, John; Balooch, Guive; Pielak, Rafal M

    2018-01-01

    Excessive ultraviolet (UV) radiation induces acute and chronic effects on the skin, eye and immune system. Personalized monitoring of UV radiation is thus paramount to measure the extent of personal sun exposure, which could vary with environment, lifestyle, and sunscreen use. Here, we demonstrate an ultralow modulus, stretchable, skin-mounted UV patch that measures personal UV doses. The patch contains functional layers of ultrathin stretchable electronics and a photosensitive patterned dye that reacts to UV radiation. Color changes in the photosensitive dyes correspond to UV radiation intensity and are analyzed with a smartphone camera. A software application has feature recognition, lighting condition correction, and quantification algorithms that detect and quantify changes in color. These color changes are then correlated with corresponding shifts in UV dose, and compared to existing UV dose risk levels. The soft mechanics of the UV patch allow for multi-day wear in the presence of sunscreen and water. Two evaluation studies serve to demonstrate the utility of the UV patch during daily activities with and without sunscreen application.

  17. Soft, stretchable, epidermal sensor with integrated electronics and photochemistry for measuring personal UV exposures

    PubMed Central

    Shi, Yunzhou; Manco, Megan; Moyal, Dominique; Huppert, Gil; Araki, Hitoshi; Banks, Anthony; Joshi, Hemant; McKenzie, Richard; Seewald, Alex; Griffin, Guy; Sen-Gupta, Ellora; Wright, Donald; Bastien, Philippe; Valceschini, Florent; Seité, Sophie; Wright, John A.; Ghaffari, Roozbeh; Rogers, John; Balooch, Guive

    2018-01-01

    Excessive ultraviolet (UV) radiation induces acute and chronic effects on the skin, eye and immune system. Personalized monitoring of UV radiation is thus paramount to measure the extent of personal sun exposure, which could vary with environment, lifestyle, and sunscreen use. Here, we demonstrate an ultralow modulus, stretchable, skin-mounted UV patch that measures personal UV doses. The patch contains functional layers of ultrathin stretchable electronics and a photosensitive patterned dye that reacts to UV radiation. Color changes in the photosensitive dyes correspond to UV radiation intensity and are analyzed with a smartphone camera. A software application has feature recognition, lighting condition correction, and quantification algorithms that detect and quantify changes in color. These color changes are then correlated with corresponding shifts in UV dose, and compared to existing UV dose risk levels. The soft mechanics of the UV patch allow for multi-day wear in the presence of sunscreen and water. Two evaluation studies serve to demonstrate the utility of the UV patch during daily activities with and without sunscreen application. PMID:29293664

  18. A Mesoscale Total Dissolved Solids Quantity and Quality Study Integrating Responses of Multiple Biological Components in Small Stream Communities

    EPA Science Inventory

    A 42-day dosing test with ions comprising an excess TDS was run using mesocosms colonized with natural stream water fed continuously. In gridded gravel beds biota from microbes through macroinvertebrates are measured and interact in a manner realistic of stream riffle/run ecology...

  19. EXPOSURE DOSE REPONSE MODELING FOR THE EFFECTS OF HAZARDOUS AIR POLLUTANTS ON HEALTH: TRICHLOROETHYLENE

    EPA Science Inventory

    Trichloroethylene (TCE) is a neurotoxic volatile organic compound (VOC) that is produced in large quantities as a degreasing agent and general solvent, and it appears on the list of 188 HAPs specified by the Clean Air Act Amendments of 1990. TCE was selected as a model VOC for de...

  20. Evaluation of Background Exposures of Americans to Dioxin-Like Compounds in the 1990's and the 2000's

    USDA-ARS?s Scientific Manuscript database

    The US Environmental Protection Agency’s 2004 Dioxin Reassessment included a characterization of background exposures to dioxin-like compounds, including an estimate of an average background intake dose and an average background body burden. These quantities were derived from data generated in the m...

  1. Effect of quantity and route of administration of manganese monoxide on feed intake and serum manganese in ruminants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Black, J.R.; Ammerman, C.B.; Henry, P.R.

    1985-02-01

    The experiment investigated effects of high quantities of manganese and route of administration (diet versus capsule-dosed) on feed intake and blood characteristics in sheep. Twenty-four Florida native or Florida native by St. Croix crossbred wethers, 47 kg initially, were assigned randomly to eight treatments including basal diet supplemented with 0, 3000, 6000, or 9000 ppm manganese as a reagent grade manganese monoxide or basal diet plus gelatin capsules containing the equivalent of 0, 3000, 6000, or 9000 ppm manganese based on intake of the previous day. Three sheep per treatment were provided feed and tap water for ad libitum intake.more » Sheep were fed basal diet for 7 days followed by a 21-day experimental period, then placed back on the basal diet for 7 days. Average daily feed intake was reduced by increasing supplemental manganese, regardless of route. Animals dosed by capsule consumed less feed than those administered manganese in the diet. Serum manganese increased as manganese supplementation increased, but route of administration had no effect.« less

  2. Radiation Doses from the Norwegian Diet.

    PubMed

    Komperød, Mari; Skuterud, Lavrans

    2018-06-13

    Ingestion doses between and within countries are expected to vary significantly due to differences in dietary habits and geographical variations in radionuclide concentrations. This paper presents the most comprehensive assessment to date of the effective radiation dose from the Norwegian diet, from natural as well as anthropogenic radionuclides. Ingestion doses to the Norwegian public are calculated using national dietary statistics and the most relevant radionuclide concentration data for the various food products. The age-weighted average effective dose received by the Norwegian population from the diet is estimated at 0.41 mSv y from naturally occurring radionuclides and 0.010 mSv y from anthropogenic radionuclides. This is approximately 50% higher than the estimated world average. Fish and shellfish is the food group that provides the largest dose contribution from the average Norwegian diet. Although the average dose from anthropogenic radionuclides today is low, the exposure may still be significant for certain critical groups-especially persons who consume large amounts of reindeer meat from the regions that received significant radioactive fallout after the Chernobyl accident. Furthermore, persons with high Rn concentrations in their drinking water are among those receiving the highest ingestion doses in Norway.

  3. Influence of therapist competence and quantity of cognitive behavioural therapy on suicidal behaviour and inpatient hospitalisation in a randomised controlled trial in borderline personality disorder: further analyses of treatment effects in the BOSCOT study.

    PubMed

    Norrie, John; Davidson, Kate; Tata, Philip; Gumley, Andrew

    2013-09-01

    We investigated the treatment effects reported from a high-quality randomized controlled trial of cognitive behavioural therapy (CBT) for 106 people with borderline personality disorder attending community-based clinics in the UK National Health Service - the BOSCOT trial. Specifically, we examined whether the amount of therapy and therapist competence had an impact on our primary outcome, the number of suicidal acts, using instrumental variables regression modelling. Randomized controlled trial. Participants from across three sites (London, Glasgow, and Ayrshire/Arran) were randomized equally to CBT for personality disorders (CBTpd) plus Treatment as Usual or to Treatment as Usual. Treatment as Usual varied between sites and individuals, but was consistent with routine treatment in the UK National Health Service at the time. CBTpd comprised an average 16 sessions (range 0-35) over 12 months. We used instrumental variable regression modelling to estimate the impact of quantity and quality of therapy received (recording activities and behaviours that took place after randomization) on number of suicidal acts and inpatient psychiatric hospitalization. A total of 101 participants provided full outcome data at 2 years post randomization. The previously reported intention-to-treat (ITT) results showed on average a reduction of 0.91 (95% confidence interval 0.15-1.67) suicidal acts over 2 years for those randomized to CBT. By incorporating the influence of quantity of therapy and therapist competence, we show that this estimate of the effect of CBTpd could be approximately two to three times greater for those receiving the right amount of therapy from a competent therapist. Trials should routinely control for and collect data on both quantity of therapy and therapist competence, which can be used, via instrumental variable regression modelling, to estimate treatment effects for optimal delivery of therapy. Such estimates complement rather than replace the ITT results, which are properly the principal analysis results from such trials. © 2013 The British Psychological Society.

  4. Ant colony algorithm implementation in electron and photon Monte Carlo transport: application to the commissioning of radiosurgery photon beams.

    PubMed

    García-Pareja, S; Galán, P; Manzano, F; Brualla, L; Lallena, A M

    2010-07-01

    In this work, the authors describe an approach which has been developed to drive the application of different variance-reduction techniques to the Monte Carlo simulation of photon and electron transport in clinical accelerators. The new approach considers the following techniques: Russian roulette, splitting, a modified version of the directional bremsstrahlung splitting, and the azimuthal particle redistribution. Their application is controlled by an ant colony algorithm based on an importance map. The procedure has been applied to radiosurgery beams. Specifically, the authors have calculated depth-dose profiles, off-axis ratios, and output factors, quantities usually considered in the commissioning of these beams. The agreement between Monte Carlo results and the corresponding measurements is within approximately 3%/0.3 mm for the central axis percentage depth dose and the dose profiles. The importance map generated in the calculation can be used to discuss simulation details in the different parts of the geometry in a simple way. The simulation CPU times are comparable to those needed within other approaches common in this field. The new approach is competitive with those previously used in this kind of problems (PSF generation or source models) and has some practical advantages that make it to be a good tool to simulate the radiation transport in problems where the quantities of interest are difficult to obtain because of low statistics.

  5. Modeling potential responses to smallpox as a bioterrorist weapon.

    PubMed

    Meltzer, M I; Damon, I; LeDuc, J W; Millar, J D

    2001-01-01

    We constructed a mathematical model to describe the spread of smallpox after a deliberate release of the virus. Assuming 100 persons initially infected and 3 persons infected per infectious person, quarantine alone could stop disease transmission but would require a minimum daily removal rate of 50% of those with overt symptoms. Vaccination would stop the outbreak within 365 days after release only if disease transmission were reduced to <0.85 persons infected per infectious person. A combined vaccination and quarantine campaign could stop an outbreak if a daily quarantine rate of 25% were achieved and vaccination reduced smallpox transmission by > or = 33%. In such a scenario, approximately 4,200 cases would occur and 365 days would be needed to stop the outbreak. Historical data indicate that a median of 2,155 smallpox vaccine doses per case were given to stop outbreaks, implying that a stockpile of 40 million doses should be adequate.

  6. The successful pharmacological treatment of adolescents and young adults with borderline personality disorder: a preliminary open trial of flupenthixol.

    PubMed Central

    Kutcher, S; Papatheodorou, G; Reiter, S; Gardner, D

    1995-01-01

    Borderline personality disorder is a significantly disabling disturbance often arising in adolescents or young adults. In the absence of demonstrated effective treatments in this population, this open prospective study evaluated the effect of low dose (3 mg per day) flupenthixol in 13 rigorously diagnosed adolescents with borderline personality disorder. Therapeutic outcome over eight weeks of treatment assessed across measures of impulsivity, depression/dysphoria, general psychopathology and global functioning showed significant improvement in all spheres. These findings suggest that low dose flupenthixol may have a role to play in the short-term treatment of this population. PMID:7703220

  7. Distributed Leadership and Teachers' Affective Commitment

    ERIC Educational Resources Information Center

    Ross, Lisa; Lutfi, Ghazwan A.; Hope, Warren C.

    2016-01-01

    Principals' responsibilities have escalated in quantity and complexity. Mandates to increase student achievement and improve school grades overwhelm one person. Hence, principals are obliged to enlist teachers to serve in leadership roles. This research sought to determine whether there is a relationship between distributed leadership and teacher…

  8. Space Radiation Organ Doses for Astronauts on Past and Future Missions

    NASA Technical Reports Server (NTRS)

    Cucinotta, Francis A.

    2007-01-01

    We review methods and data used for determining astronaut organ dose equivalents on past space missions including Apollo, Skylab, Space Shuttle, NASA-Mir, and International Space Station (ISS). Expectations for future lunar missions are also described. Physical measurements of space radiation include the absorbed dose, dose equivalent, and linear energy transfer (LET) spectra, or a related quantity, the lineal energy (y) spectra that is measured by a tissue equivalent proportional counter (TEPC). These data are used in conjunction with space radiation transport models to project organ specific doses used in cancer and other risk projection models. Biodosimetry data from Mir, STS, and ISS missions provide an alternative estimate of organ dose equivalents based on chromosome aberrations. The physical environments inside spacecraft are currently well understood with errors in organ dose projections estimated as less than plus or minus 15%, however understanding the biological risks from space radiation remains a difficult problem because of the many radiation types including protons, heavy ions, and secondary neutrons for which there are no human data to estimate risks. The accuracy of projections of organ dose equivalents described here must be supplemented with research on the health risks of space exposure to properly assess crew safety for exploration missions.

  9. Variation of indoor radon concentration and ambient dose equivalent rate in different outdoor and indoor environments.

    PubMed

    Stojanovska, Zdenka; Boev, Blazo; Zunic, Zora S; Ivanova, Kremena; Ristova, Mimoza; Tsenova, Martina; Ajka, Sorsa; Janevik, Emilija; Taleski, Vaso; Bossew, Peter

    2016-05-01

    Subject of this study is an investigation of the variations of indoor radon concentration and ambient dose equivalent rate in outdoor and indoor environments of 40 dwellings, 31 elementary schools and five kindergartens. The buildings are located in three municipalities of two, geologically different, areas of the Republic of Macedonia. Indoor radon concentrations were measured by nuclear track detectors, deployed in the most occupied room of the building, between June 2013 and May 2014. During the deploying campaign, indoor and outdoor ambient dose equivalent rates were measured simultaneously at the same location. It appeared that the measured values varied from 22 to 990 Bq/m(3) for indoor radon concentrations, from 50 to 195 nSv/h for outdoor ambient dose equivalent rates, and from 38 to 184 nSv/h for indoor ambient dose equivalent rates. The geometric mean value of indoor to outdoor ambient dose equivalent rates was found to be 0.88, i.e. the outdoor ambient dose equivalent rates were on average higher than the indoor ambient dose equivalent rates. All measured can reasonably well be described by log-normal distributions. A detailed statistical analysis of factors which influence the measured quantities is reported.

  10. On the feasibility of utilizing active personal dosimeters worn on the chest to estimate occupational eye lens dose in x-ray angiography.

    PubMed

    Omar, Artur; Marteinsdottir, Maria; Kadesjö, Nils; Fransson, Annette

    2015-06-01

    The International Commission on Radiological Protection (ICRP) has recommended that the occupational dose limit to the eye lens be substantially reduced. To ensure compliance with these recommendations, monitoring of the occupational eye lens dose is essential in certain hospital work environments. For assessment of the eye lens dose it is recommended to use a supplementary dosimeter placed at a position adjacent to the eye(s). Wearing a dosimeter at eye level can, however, be impractical and distributing and managing additional dosimeters over long periods of time is cumbersome and costly for large clinical sites. An attractive alternative is to utilize active personal dosimeters (APDs), which are routinely used by clinical staff for real-time monitoring of the personal dose equivalent rate (H(p)(10)). In this work, a formalism for the determination of eye lens dose from the response of such APD's worn on the chest is proposed and evaluated. The evaluation is based on both phantom and clinical measurements performed in an x-ray angiography suite for interventional cardiology. The main results show that the eye lens dose to the primary operator and to the assisting clinical staff can be conservatively estimated from the APD response as D(eye)(conductor) = 2.0 APD chest and D(eye)(assisting) = 1.0 APD chest, respectively. However, care should be exercised for particularly short assisting staff and if radiation protection shields are misused. These concerns can be greatly mitigated if the clinical staff are provided with adequate radiation protection training.

  11. CEM43°C thermal dose thresholds: a potential guide for magnetic resonance radiofrequency exposure levels?

    PubMed

    van Rhoon, Gerard C; Samaras, Theodoros; Yarmolenko, Pavel S; Dewhirst, Mark W; Neufeld, Esra; Kuster, Niels

    2013-08-01

    To define thresholds of safe local temperature increases for MR equipment that exposes patients to radiofrequency fields of high intensities for long duration. These MR systems induce heterogeneous energy absorption patterns inside the body and can create localised hotspots with a risk of overheating. The MRI + EUREKA research consortium organised a "Thermal Workshop on RF Hotspots". The available literature on thresholds for thermal damage and the validity of the thermal dose (TD) model were discussed. The following global TD threshold guidelines for safe use of MR are proposed: 1. All persons: maximum local temperature of any tissue limited to 39 °C 2. Persons with compromised thermoregulation AND (a) Uncontrolled conditions: maximum local temperature limited to 39 °C (b) Controlled conditions: TD < 2 CEM43°C 3. Persons with uncompromised thermoregulation AND (a) Uncontrolled conditions: TD < 2 CEM43°C (b) Controlled conditions: TD < 9 CEM43°C The following definitions are applied: Controlled conditions A medical doctor or a dedicated trained person can respond instantly to heat-induced physiological stress Compromised thermoregulation All persons with impaired systemic or reduced local thermoregulation • Standard MRI can cause local heating by radiofrequency absorption. • Monitoring thermal dose (in units of CEM43°C) can control risk during MRI. • 9 CEM43°C seems an acceptable thermal dose threshold for most patients. • For skin, muscle, fat and bone,16 CEM43°C is likely acceptable.

  12. Health physics aspects of advanced reactor licensing reviews

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hinson, C.S.

    1995-03-01

    The last Construction Permit to be issued by the U.S. Nuclear Regulatory Commission (NRC) for a U.S. light water reactor (LWR) was granted in the late 1970s. In 1989 the NRC issued 10 CFR Part 52 which is intended to serve as a framework for the licensing of future reactor designs. The NRC is currently reviewing four different future on {open_quotes}next-generation{close_quotes} reactor designs. Two of these designs are classified as evolutionary designs (modified versions of current generation LWRs) and two are advanced designs (reactors incorporating simplified designs and passive means for accident mitigation). These {open_quotes}next-generation{close_quotes} reactor designs incorporate many innovativemore » design features which are intended to maintain personnel doses ALARA and ensure that the annual average collective dose at these reactors does not exceed 100 person-rems (1 person-sievert) per year. This paper discusses some of the ALARA design features which are incorporated in the four {open_quotes}next-generation{close_quotes} reactor designs incorporate many innovative design features which are intended to maintain personnel doses ALARA and ensure that the annual average collective dose at these reactors does not exceed 100 person-rems (1 person-sievert) per year. This paper discusses some of the ALARA design features which are incorporated in the four {open_quotes}next-generation{close_quotes} reactor designs currently being reviewed by the NRC.« less

  13. Beneficial effects of low dose Musa paradisiaca on the semen quality of male Wistar rats

    PubMed Central

    Alabi, A. S.; Omotoso, Gabriel O.; Enaibe, B. U.; Akinola, O. B.; Tagoe, C. N. B.

    2013-01-01

    Background: This study aimed at determining the effects of administration of mature green fruits of Musa paradisiaca on the semen quality of adult male Wistar rats. Materials and Methods: The animals used for the study were grouped into three: the control group, given 2 ml of double distilled water, a low dose group given 500 mg/kg/day and a high dose group given 1000 mg/kg/day of the plantain fruits, which was made into flour, and dissolved in 2 ml of double distilled water for easy oral administration. Results: Significant increment in the semen parameters was noticed in animals that received a lower dose of the plantain flour, but those animals who received the high dose had marked and very significant reduction in sperm cell concentration and percentage of morphologically normal spermatozoa. Conclusion: Musa paradisiaca should be consumed in moderate quantities in order to derive its beneficial effects of enhancing male reproductive functions. PMID:23798793

  14. Radiation Dose-Volume Effects in the Stomach and Small Bowel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kavanagh, Brian D., E-mail: Brian.Kavanagh@ucdenver.ed; Pan, Charlie C.; Dawson, Laura A.

    2010-03-01

    Published data suggest that the risk of moderately severe (>=Grade 3) radiation-induced acute small-bowel toxicity can be predicted with a threshold model whereby for a given dose level, D, if the volume receiving that dose or greater (VD) exceeds a threshold quantity, the risk of toxicity escalates. Estimates of VD depend on the means of structure segmenting (e.g., V15 = 120 cc if individual bowel loops are outlined or V45 = 195 cc if entire peritoneal potential space of bowel is outlined). A similar predictive model of acute toxicity is not available for stomach. Late small-bowel/stomach toxicity is likely relatedmore » to maximum dose and/or volume threshold parameters qualitatively similar to those related to acute toxicity risk. Concurrent chemotherapy has been associated with a higher risk of acute toxicity, and a history of abdominal surgery has been associated with a higher risk of late toxicity.« less

  15. Air kerma and absorbed dose standards for reference dosimetry in brachytherapy

    PubMed Central

    2014-01-01

    This article reviews recent developments in primary standards for the calibration of brachytherapy sources, with an emphasis on the currently most common photon-emitting radionuclides. The introduction discusses the need for reference dosimetry in brachytherapy in general. The following section focuses on the three main quantities, i.e. reference air kerma rate, air kerma strength and absorbed dose rate to water, which are currently used for the specification of brachytherapy photon sources and which can be realized with primary standards from first principles. An overview of different air kerma and absorbed dose standards, which have been independently developed by various national metrology institutes over the past two decades, is given in the next two sections. Other dosimetry techniques for brachytherapy will also be discussed. The review closes with an outlook on a possible transition from air kerma to absorbed dose to water-based calibrations for brachytherapy sources in the future. PMID:24814696

  16. The work of the ICRP dose calculational task group: Issues in implementation of the ICRP dosimetric methodology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eckerman, K.F.

    Committee 2 of the International Commission on Radiological Protection (ICRP) has had efforts underway to provide the radiation protection community with age-dependent dose coefficients, i.e.g, the dose per unit intake. The Task Group on Dose Calculations, chaired by the author, is responsible for the computation of these coefficients. The Task Group, formed in 1974 to produce ICRP Publication 30, is now international in its membership and its work load has been distributed among the institutions represented on the task group. This paper discusses: (1) recent advances in biokinetic modeling; (2) the recent changes in the dosimetric methodology; (3) the novelmore » computational problems with some of the ICRP quantities; and (4) quality assurance issues which the Task Group has encountered. Potential future developments of the dosimetric framework which might strengthen the relationships with the emerging understanding of radiation risk will also be discussed.« less

  17. Safe pill-dispensing.

    PubMed

    Testa, Massimiliano; Pollard, John

    2007-01-01

    Each patient is supplied with a smart-card containing a Radio Frequency IDentification (RFID) chip storing a unique identification code. The patient places the Smart-card on a pill-dispenser unit containing an RFID reader. The RFID chip is read and the code sent to a Base-station via a wireless Bluetooth link. A database containing both patient details and treatment information is queried at the Base-station using the RFID as the search key. The patient's treatment data (i.e., drug names, quantities, time, etc.) are retrieved and sent back to the pill-dispenser unit via Bluetooth. Appropriate quantities of the required medications are automatically dispensed, unless the patient has already taken his/her daily dose. Safe, confidential communication and operation is ensured.

  18. The Quantity and Quality of Illegally Imported Products of Animal Origin in Personal Consignments into the European Union Seized at Two German Airports between 2010 And 2014

    PubMed Central

    Jansen, Wiebke; Merkle, Majella; Daun, Anna; Flor, Matthias; Grabowski, Nils Th.; Klein, Günter

    2016-01-01

    The import of products of animal origin (POAO) in travellers’ personal consignments presents a considerable risk of introducing animal diseases and emerging zoonoses into the European Union. The current regulation (EU) 206/2009 implements strict measures for illegally imported POAO, whereupon non-complying products have to be seized and destroyed regardless. Especially airports serve as global bottlenecks for illegally imported POAO where passenger controls of non-European flights are performed by customs and veterinary services in collaboration. Results of these control measures have to be submitted in the form of annual reports to the European Commission. However, few data on qualities and quantities of seizures have been published so far. In this study, POAO seized at two German airports between 2010 and 2014 were analysed in terms of quantities, qualitative categories and region of origin. In most years considered, more than 20 tonnes POAO were seized at each airport. However, reported amounts of seizures seem to be only the tip of the iceberg as an all-passenger control is not feasible and therefore travellers are only spot-checked. The analysis suggests that the organisational structures of both customs and official veterinary services and their different risk perceptions interfere in completing an effective ban on the illegal import of POAO. PMID:26901158

  19. The Quantity and Quality of Illegally Imported Products of Animal Origin in Personal Consignments into the European Union Seized at Two German Airports between 2010 And 2014.

    PubMed

    Jansen, Wiebke; Merkle, Majella; Daun, Anna; Flor, Matthias; Grabowski, Nils Th; Klein, Günter

    2016-01-01

    The import of products of animal origin (POAO) in travellers' personal consignments presents a considerable risk of introducing animal diseases and emerging zoonoses into the European Union. The current regulation (EU) 206/2009 implements strict measures for illegally imported POAO, whereupon non-complying products have to be seized and destroyed regardless. Especially airports serve as global bottlenecks for illegally imported POAO where passenger controls of non-European flights are performed by customs and veterinary services in collaboration. Results of these control measures have to be submitted in the form of annual reports to the European Commission. However, few data on qualities and quantities of seizures have been published so far. In this study, POAO seized at two German airports between 2010 and 2014 were analysed in terms of quantities, qualitative categories and region of origin. In most years considered, more than 20 tonnes POAO were seized at each airport. However, reported amounts of seizures seem to be only the tip of the iceberg as an all-passenger control is not feasible and therefore travellers are only spot-checked. The analysis suggests that the organisational structures of both customs and official veterinary services and their different risk perceptions interfere in completing an effective ban on the illegal import of POAO.

  20. Performance of Panasonic ZP-1460 Electronic Personal Dosemeter under Exposure Conditions Likely to be Found at Fukushima Daiichi Nuclear Power Plant

    NASA Astrophysics Data System (ADS)

    Tsujimura, Norio; Yoshida, Tadayoshi; Hoshi, Katsuya; Momose, Takumaro

    A study on the performance of the Panasonic ZP-1460 electronic personal dosemeter, the model used in the aftermath of the Fukushima Daiichi nuclear power plant accident in March 2011, was conducted under actual exposure situations likely encountered in the plant. The tests pertained to (1) the dose rate response over dose rates >100 mSv/h and (2) the angular response on an anthropomorphic phantom exposed to the rotational and isotropic irradiation geometries. The test results confirmed that the dosemeter provides Hp(10) as a reasonably close estimate of the effective dose for any exposure geometries. The dosemeter response data evaluated in this study can be utilized for converting dosemeter readings to the absorbed dose to any organs and tissues for epidemiologic purposes.

  1. 36 CFR 212.1 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... materials investigations, surveys, and tests; (6) Preliminary and final designs; (7) Preliminary and final... surveys to establish line and grade for the work, to control the work, and to measure quantities; (2... battery-powered, that is designed solely for use by a mobility-impaired person for locomotion, and that is...

  2. 36 CFR 212.1 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... materials investigations, surveys, and tests; (6) Preliminary and final designs; (7) Preliminary and final... surveys to establish line and grade for the work, to control the work, and to measure quantities; (2... battery-powered, that is designed solely for use by a mobility-impaired person for locomotion, and that is...

  3. 36 CFR 212.1 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... materials investigations, surveys, and tests; (6) Preliminary and final designs; (7) Preliminary and final... surveys to establish line and grade for the work, to control the work, and to measure quantities; (2... battery-powered, that is designed solely for use by a mobility-impaired person for locomotion, and that is...

  4. Perspectives on Federal Educational Policy: An Informal Colloquium.

    ERIC Educational Resources Information Center

    Andringa, Robert; And Others

    In an attempt to spotlight issues of federal aid to education (including quantities, destinations, delivery mechanisms, and rationale), and their probable effects, the Institute for Educational Leadership assembled a five-person bipartisan group of policy observers for two spontaneous discussions. This edited transcript of those sessions covers…

  5. Followership: A Classroom Exercise to Introduce the Concept

    ERIC Educational Resources Information Center

    Hurwitz, Marc

    2017-01-01

    Followership is valuable for personal and organizational success, whether success is measured by satisfaction with work, improved team relationships, obtaining promotions, or quality and quantity of work output. Furthermore, senior executives and coaches recognize it as a critical skill. Despite this, creating effective followership training in…

  6. 10 CFR 32.19 - Same: Conditions of licenses.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... NUCLEAR REGULATORY COMMISSION SPECIFIC DOMESTIC LICENSES TO MANUFACTURE OR TRANSFER CERTAIN ITEMS... set forth in § 30.71, Schedule B of this chapter shall be sold or transferred in any single... packaged exempt quantities shall be contained in any outer package for transfer to persons exempt pursuant...

  7. 10 CFR 32.19 - Same: Conditions of licenses.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... NUCLEAR REGULATORY COMMISSION SPECIFIC DOMESTIC LICENSES TO MANUFACTURE OR TRANSFER CERTAIN ITEMS... set forth in § 30.71, Schedule B of this chapter shall be sold or transferred in any single... packaged exempt quantities shall be contained in any outer package for transfer to persons exempt pursuant...

  8. Association of Medicare's Bundled Payment Reform With Changes in Use of Vitamin D Among Patients Receiving Maintenance Hemodialysis: An Interrupted Time-Series Analysis.

    PubMed

    Spoendlin, Julia; Schneeweiss, Sebastian; Tsacogianis, Theodore; Paik, Julie M; Fischer, Michael A; Kim, Seoyoung C; Desai, Rishi J

    2018-06-08

    Medicare's 2011 prospective payment system (PPS) was introduced to curb overuse of separately billable injectable drugs. After epoietin, intravenous (IV) vitamin D analogues are the biggest drug cost drivers in hemodialysis (HD) patients, but the association between PPS introduction and vitamin D therapy has been scarcely investigated. Interrupted time-series analyses. Adult US HD patients represented in the US Renal Data System between 2008 and 2013. PPS implementation. The cumulative dose of IV vitamin D analogues (paricalcitol equivalents) per patient per calendar quarter in prevalent HD patients. The average starting dose of IV vitamin D analogues and quarterly rates of new vitamin D use (initiations/100 person-months) in incident HD patients within 90 days of beginning HD therapy. Segmented linear regression models of the immediate change and slope change over time of vitamin D use after PPS implementation. Among 359,600 prevalent HD patients, IV vitamin D analogues accounted for 99% of the total use, and this trend was unchanged over time. PPS resulted in an immediate 7% decline in the average dose of IV vitamin D analogues (average baseline dose = 186.5 μg per quarter; immediate change = -13.5 μg [P < 0.001]; slope change = 0.43 per quarter [P = 0.3]) and in the starting dose of IV vitamin D analogues in incident HD patients (average baseline starting dose = 5.22 μg; immediate change = -0.40 μg [P < 0.001]; slope change = -0.03 per quarter [P = 0.03]). The baseline rate of vitamin D therapy initiation among 99,970 incident HD patients was 44.9/100 person-months and decreased over time, even before PPS implementation (pre-PPS β = -0.46/100 person-months [P < 0.001]; slope change = -0.19/100 person-months [P = 0.2]). PPS implementation was associated with an immediate change in initiation levels (by -4.5/100 person-months; P < 0.001). Incident HD patients were restricted to those 65 years or older. PPS implementation was associated with a 7% reduction in the average dose and starting dose of IV vitamin D analogues and a 10% reduction in the rate of vitamin D therapy initiation. Copyright © 2018 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  9. Radiolysis products and sensory properties of electron-beam-irradiated high-barrier food-packaging films containing a buried layer of recycled low-density polyethylene.

    PubMed

    Chytiri, S D; Badeka, A V; Riganakos, K A; Kontominas, M G

    2010-04-01

    The aim was to study the effect of electron-beam irradiation on the production of radiolysis products and sensory changes in experimental high-barrier packaging films composed of polyamide (PA), ethylene-vinyl alcohol (EVOH) and low-density polyethylene (LDPE). Films contained a middle buried layer of recycled LDPE, while films containing 100% virgin LDPE as the middle buried layer were taken as controls. Irradiation doses ranged between zero and 60 kGy. Generally, a large number of radiolysis products were produced during electron-beam irradiation, even at the lower absorbed doses of 5 and 10 kGy (approved doses for food 'cold pasteurization'). The quantity of radiolysis products increased with irradiation dose. There were no significant differences in radiolysis products identified between samples containing a recycled layer of LDPE and those containing virgin LDPE (all absorbed doses), indicating the 'functional barrier' properties of external virgin polymer layers. Sensory properties (mainly taste) of potable water were affected after contact with irradiated as low as 5 kGy packaging films. This effect increased with increasing irradiation dose.

  10. Radiation exposure in X-ray-based imaging techniques used in osteoporosis

    PubMed Central

    Adams, Judith E.; Guglielmi, Giuseppe; Link, Thomas M.

    2010-01-01

    Recent advances in medical X-ray imaging have enabled the development of new techniques capable of assessing not only bone quantity but also structure. This article provides (a) a brief review of the current X-ray methods used for quantitative assessment of the skeleton, (b) data on the levels of radiation exposure associated with these methods and (c) information about radiation safety issues. Radiation doses associated with dual-energy X-ray absorptiometry are very low. However, as with any X-ray imaging technique, each particular examination must always be clinically justified. When an examination is justified, the emphasis must be on dose optimisation of imaging protocols. Dose optimisation is more important for paediatric examinations because children are more vulnerable to radiation than adults. Methods based on multi-detector CT (MDCT) are associated with higher radiation doses. New 3D volumetric hip and spine quantitative computed tomography (QCT) techniques and high-resolution MDCT for evaluation of bone structure deliver doses to patients from 1 to 3 mSv. Low-dose protocols are needed to reduce radiation exposure from these methods and minimise associated health risks. PMID:20559834

  11. The affect of low-coherent light on microbial colony forming ability and morphology of some gram-positive and gram-negative bacteria

    NASA Astrophysics Data System (ADS)

    Popov, Denis E.; Tuchina, Elena S.; Chernova, Julia A.; Podshibyakin, Dmitry; Rudik, Dmitry V.; Samsonova, Maria; Gromov, Igor; Tuchin, Valery V.

    2005-06-01

    Gram-negative E. coli, gram-positive facultative anaerobe cocci Staphylococcus lugdensis, Micrococcus halobius, and Stomatococcus mucilaginosus as subjects of study were chosen. LEDs with spectrum maxima at 405 nm (without any exogenous sensitizer) and 660 nm (in conjunction with methylene blue) and power densities of 23 mW/cm2 and 5.7 mW/cm2 accordingly as continuous light sources were chosen. Photosensitized light's affect by methylene blue was studied on E. coli only. The original scheme of experiment set up was developed. It permits one to increase expositions quantity in each experiment for more certain trend's construction over dose curves and decrease parasite flora sowing. As a result of accomplished studies it was established that blue low-coherent light have unalike weak light's dose depending suppressing effect on cocci whereas red low-coherent light have a moderate dose-depended suppressing effect at low irradiation doses and a moderate dose-depended stimulating effect at high irradiation doses on sensitized by MeBlue E. coli. For all ofthis, but Staphylococcus morphology changes were observed.

  12. Cost-effectiveness of CT screening in the National Lung Screening Trial.

    PubMed

    Black, William C; Gareen, Ilana F; Soneji, Samir S; Sicks, JoRean D; Keeler, Emmett B; Aberle, Denise R; Naeim, Arash; Church, Timothy R; Silvestri, Gerard A; Gorelick, Jeremy; Gatsonis, Constantine

    2014-11-06

    The National Lung Screening Trial (NLST) showed that screening with low-dose computed tomography (CT) as compared with chest radiography reduced lung-cancer mortality. We examined the cost-effectiveness of screening with low-dose CT in the NLST. We estimated mean life-years, quality-adjusted life-years (QALYs), costs per person, and incremental cost-effectiveness ratios (ICERs) for three alternative strategies: screening with low-dose CT, screening with radiography, and no screening. Estimations of life-years were based on the number of observed deaths that occurred during the trial and the projected survival of persons who were alive at the end of the trial. Quality adjustments were derived from a subgroup of participants who were selected to complete quality-of-life surveys. Costs were based on utilization rates and Medicare reimbursements. We also performed analyses of subgroups defined according to age, sex, smoking history, and risk of lung cancer and performed sensitivity analyses based on several assumptions. As compared with no screening, screening with low-dose CT cost an additional $1,631 per person (95% confidence interval [CI], 1,557 to 1,709) and provided an additional 0.0316 life-years per person (95% CI, 0.0154 to 0.0478) and 0.0201 QALYs per person (95% CI, 0.0088 to 0.0314). The corresponding ICERs were $52,000 per life-year gained (95% CI, 34,000 to 106,000) and $81,000 per QALY gained (95% CI, 52,000 to 186,000). However, the ICERs varied widely in subgroup and sensitivity analyses. We estimated that screening for lung cancer with low-dose CT would cost $81,000 per QALY gained, but we also determined that modest changes in our assumptions would greatly alter this figure. The determination of whether screening outside the trial will be cost-effective will depend on how screening is implemented. (Funded by the National Cancer Institute; NLST ClinicalTrials.gov number, NCT00047385.).

  13. Study of UV radiation dose received by the Spanish population.

    PubMed

    Gurrea, Gonzalo; Cañada, Javier

    2007-01-01

    Excess exposure to UV radiation can affect our health by causing sunburn, skin cancer, etc. It is therefore useful to determine the UV dosage received by people as a way of protecting them from the possible negative effects that this kind of radiation can cause. In this work, the personal outdoor percentage, which shows the time spent in outdoor activities, as well as personal UV doses, has been calculated by means of global UV radiation on a horizontal plane. A database of average daily UVB radiation on the horizontal plane given by the National Institute of Meteorology has been used. In this work we evaluate the standard erythema dose of the Spanish population throughout the year.

  14. College drinking problems and social anxiety: The importance of drinking context.

    PubMed

    Terlecki, Meredith A; Ecker, Anthony H; Buckner, Julia D

    2014-06-01

    Social anxiety more than quadruples the risk of developing an alcohol use disorder, yet it is inconsistently linked to heavy alcohol use. Elucidation of the relation between social anxiety and alcohol use is an important next step in treating and preventing risky drinking. College students routinely face potentially anxiety-provoking social situations (e.g., meeting new people) and socially anxious undergraduates are especially vulnerable to alcohol-related impairment. Drinking to cope with social anxiety is thought to reinforce alcohol use, yet research on coping-motivated drinking among socially anxious students has yielded inconsistent findings. Further, undergraduate drinking varies by drinking context, yet the role of context in drinking behaviors among socially anxious individuals remains unclear. The current study sought to examine the relationship of social anxiety and drinking quantity in specific drinking contexts among undergraduates (N = 611). We also evaluated whether relevant drinking contexts mediated the relationship between social anxiety and alcohol-related problems. Clinically elevated social anxiety was related to heavier consumption in negative emotion (e.g., feeling sad or angry) and personal/intimate (e.g., before sexual intercourse) contexts, but not social/convivial contexts (e.g., parties, bars). Quantity of alcohol consumed in negative emotion and personal/intimate contexts mediated the relationship between social anxiety and drinking problem severity. Drinking in personal/intimate contexts demonstrated a unique mediational role. Findings suggest that heavy drinking in particular contexts (especially personal/intimate and negative emotion) may play an important role in drinking problems among socially anxious individuals.

  15. The Dose-Effect Relationship in Psychodynamic Psychotherapy with People with Intellectual Disabilities

    ERIC Educational Resources Information Center

    Beail, Nigel; Kellett, Stephen; Newman, David W.; Warden, Sharon

    2007-01-01

    Background: Although there is an established body of evidence attesting to the dose-effect relationship in psychotherapy with non-disabled adults, the issue as to whether such a relationship exists for persons with intellectual disabilities has not been previously examined. Dose-effect essentially concerns the amount of psychotherapy required to…

  16. 9 CFR 113.454 - Clostridium Perfringens Type C Antitoxin.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... sickness or death in injected mice. (iii) L + dose. The smallest quantity of toxin which can be mixed with one unit of Standard Antitoxin and cause death in at least 80 percent of injected mice. (iv) Standard... of mice can be made. (vi) Five Swiss white mice, each weighing 16-20 grams, shall be used for each...

  17. 9 CFR 113.455 - Clostridium Perfringens Type D Antitoxin.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... cause sickness or death in injected mice. (iii) L + dose. The smallest quantity of toxin which can be mixed with one-tenth unit of Standard Antitoxin and cause death in at least 80 percent of injected mice... until injections of mice can be made. (vi) Five Swiss white mice, each weighing 16-20 grams, shall be...

  18. Iodine-131 Releases from Radioactive Lanthanum Processing at the X-10 Site in Oak Ridge, Tennessee (1944-1956)- An Assessment of Quantities released, Off-Site Radiation Doses, and Potential Excess Risks of Thyroid Cancer, Volume 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Apostoaei, A.I.; Burns, R.E.; Hoffman, F.O.

    1999-07-01

    In the early 1990s, concern about the Oak Ridge Reservation's past releases of contaminants to the environment prompted Tennessee's public health officials to pursue an in-depth study of potential off-site health effects at Oak Ridge. This study, the Oak Ridge dose reconstruction, was supported by an agreement between the U.S. Department of Energy (DOE) and the State of Tennessee, and was overseen by a 12-member panel appointed by Tennessee's Commissioner of Health. One of the major contaminants studied in the dose reconstruction was radioactive iodine, which was released to the air by X-10 (now called Oak Ridge National Laboratory) asmore » it processed spent nuclear reactor fuel from 1944 through 1956. The process recovered radioactive lanthanum for use in weapons development. Iodine concentrates in the thyroid gland so health concerns include various diseases of the thyroid, such as thyroid cancer. The large report, ''Iodine-131 Releases from Radioactive Lanthanum Processing at the X-10 Site in Oak Ridge, Tennessee (1944-1956) - An Assessment of Quantities Released, Off-site Radiation Doses, and Potential Excess Risks of Thyroid Cancer,'' is in two volumes. Volume 1 is the main body of the report, and Volume 1A, which has the same title, consists of 22 supporting appendices. Together, these reports serve the following purposes: (1) describe the methodologies used to estimate the amount of iodine-131 (I-131) released; (2) evaluate I-131's pathway from air to vegetation to food to humans; (3) estimate doses received by human thyroids; (4) estimate excess risk of acquiring a thyroid cancer during ones lifetime; and (5) provide equations, examples of historical documents used, and tables of calculated values. Results indicate that females born in 1952 who consumed milk from a goat pastured a few miles east of X-10 received the highest doses from I-131 and would have had the highest risks of contracting thyroid cancer. Doses from cow's milk are considerably less . Detailed dose and risk estimates, and associated uncertainties, for other contaminants studied for the Oak Ridge dose reconstruction are presented in several other technical reports. One way to easily locate them in OSTI's Information Bridge is by searching the ''report number field'' for the number DOE/OR/21981*. Be sure to place the asterisk after the base number so your search can list the complete series of reports related to Oak Ridge Dose Reconstruction.« less

  19. Doses of Nearby Nature Simultaneously Associated with Multiple Health Benefits

    PubMed Central

    Cox, Daniel T. C.; Shanahan, Danielle F.; Hudson, Hannah L.; Fuller, Richard A.; Anderson, Karen; Hancock, Steven; Gaston, Kevin J.

    2017-01-01

    Exposure to nature provides a wide range of health benefits. A significant proportion of these are delivered close to home, because this offers an immediate and easily accessible opportunity for people to experience nature. However, there is limited information to guide recommendations on its management and appropriate use. We apply a nature dose-response framework to quantify the simultaneous association between exposure to nearby nature and multiple health benefits. We surveyed ca. 1000 respondents in Southern England, UK, to determine relationships between (a) nature dose type, that is the frequency and duration (time spent in private green space) and intensity (quantity of neighbourhood vegetation cover) of nature exposure and (b) health outcomes, including mental, physical and social health, physical behaviour and nature orientation. We then modelled dose-response relationships between dose type and self-reported depression. We demonstrate positive relationships between nature dose and mental and social health, increased physical activity and nature orientation. Dose-response analysis showed that lower levels of depression were associated with minimum thresholds of weekly nature dose. Nearby nature is associated with quantifiable health benefits, with potential for lowering the human and financial costs of ill health. Dose-response analysis has the potential to guide minimum and optimum recommendations on the management and use of nearby nature for preventative healthcare. PMID:28208789

  20. Doses of Nearby Nature Simultaneously Associated with Multiple Health Benefits.

    PubMed

    Cox, Daniel T C; Shanahan, Danielle F; Hudson, Hannah L; Fuller, Richard A; Anderson, Karen; Hancock, Steven; Gaston, Kevin J

    2017-02-09

    Exposure to nature provides a wide range of health benefits. A significant proportion of these are delivered close to home, because this offers an immediate and easily accessible opportunity for people to experience nature. However, there is limited information to guide recommendations on its management and appropriate use. We apply a nature dose-response framework to quantify the simultaneous association between exposure to nearby nature and multiple health benefits. We surveyed ca. 1000 respondents in Southern England, UK, to determine relationships between (a) nature dose type, that is the frequency and duration (time spent in private green space) and intensity (quantity of neighbourhood vegetation cover) of nature exposure and (b) health outcomes, including mental, physical and social health, physical behaviour and nature orientation. We then modelled dose-response relationships between dose type and self-reported depression. We demonstrate positive relationships between nature dose and mental and social health, increased physical activity and nature orientation. Dose-response analysis showed that lower levels of depression were associated with minimum thresholds of weekly nature dose. Nearby nature is associated with quantifiable health benefits, with potential for lowering the human and financial costs of ill health. Dose-response analysis has the potential to guide minimum and optimum recommendations on the management and use of nearby nature for preventative healthcare.

  1. Non-vascular interventional procedures: effective dose to patient and equivalent dose to abdominal organs by means of DICOM images and Monte Carlo simulation.

    PubMed

    Longo, Mariaconcetta; Marchioni, Chiara; Insero, Teresa; Donnarumma, Raffaella; D'Adamo, Alessandro; Lucatelli, Pierleone; Fanelli, Fabrizio; Salvatori, Filippo Maria; Cannavale, Alessandro; Di Castro, Elisabetta

    2016-03-01

    This study evaluates X-ray exposure in patient undergoing abdominal extra-vascular interventional procedures by means of Digital Imaging and COmmunications in Medicine (DICOM) image headers and Monte Carlo simulation. The main aim was to assess the effective and equivalent doses, under the hypothesis of their correlation with the dose area product (DAP) measured during each examination. This allows to collect dosimetric information about each patient and to evaluate associated risks without resorting to in vivo dosimetry. The dose calculation was performed in 79 procedures through the Monte Carlo simulator PCXMC (A PC-based Monte Carlo program for calculating patient doses in medical X-ray examinations), by using the real geometrical and dosimetric irradiation conditions, automatically extracted from DICOM headers. The DAP measurements were also validated by using thermoluminescent dosemeters on an anthropomorphic phantom. The expected linear correlation between effective doses and DAP was confirmed with an R(2) of 0.974. Moreover, in order to easily calculate patient doses, conversion coefficients that relate equivalent doses to measurable quantities, such as DAP, were obtained. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Cost Evaluation of a Government-Conducted Oral Cholera Vaccination Campaign-Haiti, 2013.

    PubMed

    Routh, Janell A; Sreenivasan, Nandini; Adhikari, Bishwa B; Andrecy, Lesly L; Bernateau, Margarette; Abimbola, Taiwo; Njau, Joseph; Jackson, Ernsley; Juin, Stanley; Francois, Jeannot; Tohme, Rania A; Meltzer, Martin I; Katz, Mark A; Mintz, Eric D

    2017-10-01

    The devastating 2010 cholera epidemic in Haiti prompted the government to introduce oral cholera vaccine (OCV) in two high-risk areas of Haiti. We evaluated the direct costs associated with the government's first vaccine campaign implemented in August-September 2013. We analyzed data for major cost categories and assessed the efficiency of available campaign resources to vaccinate the target population. For a target population of 107,906 persons, campaign costs totaled $624,000 and 215,295 OCV doses were dispensed. The total vaccine and operational cost was $2.90 per dose; vaccine alone cost $1.85 per dose, vaccine delivery and administration $0.70 per dose, and vaccine storage and transport $0.35 per dose. Resources were greater than needed-our analyses suggested that approximately 2.5-6 times as many persons could have been vaccinated during this campaign without increasing the resources allocated for vaccine delivery and administration. These results can inform future OCV campaigns in Haiti.

  3. Monte Carlo calculation of the radiation field at aircraft altitudes.

    PubMed

    Roesler, S; Heinrich, W; Schraube, H

    2002-01-01

    Energy spectra of secondary cosmic rays are calculated for aircraft altitudes and a discrete set of solar modulation parameters and rigidity cut-off values covering all possible conditions. The calculations are based on the Monte Carlo code FLUKA and on the most recent information on the interstellar cosmic ray flux including a detailed model of solar modulation. Results are compared to a large variety of experimental data obtained on the ground and aboard aircraft and balloons, such as neutron, proton, and muon spectra and yields of charged particles. Furthermore, particle fluence is converted into ambient dose equivalent and effective dose and the dependence of these quantities on height above sea level, solar modulation, and geographical location is studied. Finally, calculated dose equivalent is compared to results of comprehensive measurements performed aboard aircraft.

  4. Accurate condensed history Monte Carlo simulation of electron transport. II. Application to ion chamber response simulations.

    PubMed

    Kawrakow, I

    2000-03-01

    In this report the condensed history Monte Carlo simulation of electron transport and its application to the calculation of ion chamber response is discussed. It is shown that the strong step-size dependencies and lack of convergence to the correct answer previously observed are the combined effect of the following artifacts caused by the EGS4/PRESTA implementation of the condensed history technique: dose underprediction due to PRESTA'S pathlength correction and lateral correlation algorithm; dose overprediction due to the boundary crossing algorithm; dose overprediction due to the breakdown of the fictitious cross section method for sampling distances between discrete interaction and the inaccurate evaluation of energy-dependent quantities. These artifacts are now understood quantitatively and analytical expressions for their effect are given.

  5. The Bebig Valencia-type skin applicators: Dosimetric study and implementation of a dosimetric hybrid technique.

    PubMed

    Anagnostopoulos, Georgios; Andrássy, Michael; Baltas, Dimos

    To determine the relative dose rate distribution in water for the Bebig 20 mm and 30 mm skin applicators and report results in a form suitable for potential clinical use. Results for both skin applicators are also provided in the form of a hybrid Task Group 43 (TG-43) dosimetry technique. Furthermore, the radiation leakage around both skin applicators from the radiation protection point of view and the impact of the geometrical source position uncertainties are studied and reported. Monte Carlo simulations were performed using the MCNP 6.1 general purpose code, which was benchmarked against published dosimetry data for the Bebig Ir2.A85-2 high-dose-rate iridium-192 source, as well as the dosimetry data for the two Elekta skin applicators. Both Bebig skin applicators were modeled, and the dose rate distributions in a water phantom were calculated. The dosimetric quantities derived according to a hybrid TG-43 dosimetry technique are provided with their corresponding uncertainty values. The air kerma rate in air was simulated in the vicinity of each skin applicator to assess the radiation leakage. Results from the Monte Carlo simulations of both skin applicators are presented in the form of figures and relative dose rate tables, and additionally with the aid of the quantities defined in the hybrid TG-43 dosimetry technique and their corresponding uncertainty values. Their output factors, flatness, and penumbra values were found comparable to the Elekta skin applicators. The radiation shielding was evaluated to be adequate. The effect of potential uncertainties in source positioning on dosimetry should be investigated as part of applicator commissioning. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  6. New (125)I brachytherapy source IsoSeed I25.S17plus: Monte Carlo dosimetry simulation and comparison to sources of similar design.

    PubMed

    Pantelis, Evaggelos; Papagiannis, Panagiotis; Anagnostopoulos, Giorgos; Baltas, Dimos

    2013-12-01

    To determine the relative dose rate distribution around the new (125)I brachytherapy source IsoSeed I25.S17plus and report results in a form suitable for clinical use. Results for the new source are also compared to corresponding results for other commercially available (125)I sources of similar design. Monte Carlo simulations were performed using the MCNP5 v.1.6 general purpose code. The model of the new source was prepared from information provided by the manufacturer and verified by imaging a sample of ten non-radioactive sources. Corresponding simulations were also performed for the 6711 (125)I brachytherapy source, using updated geometric information presented recently in the literature. The uncertainty of the dose distribution around the new source, as well as the dosimetric quantities derived from it according to the Task Group 43 formalism, were determined from the standard error of the mean of simulations for a sample of fifty source models. These source models were prepared by randomly selecting values of geometric parameters from uniform distributions defined by manufacturer stated tolerances. Results are presented in the form of the quantities defined in the update of the Task Group 43 report, as well as a relative dose rate table in Cartesian coordinates. The dose rate distribution of the new source is comparable to that of sources of similar design (IsoSeed I25.S17, Oncoseed 6711, SelectSeed 130.002, Advantage IAI-125A, I-Seed AgX100, Thinseed 9011). Noticeable differences were observed only for the IsoSeed I25.S06 and Best 2301 sources.

  7. 43 CFR 3622.1 - Program: General.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) FREE USE OF PETRIFIED WOOD Free Use of Petrified Wood § 3622.1 Program: General. (a) Persons may collect limited quantities of petrified wood for noncommercial... recreational resource. (b) The purchase of petrified wood for commercial purposes is provided for in § 3602.10...

  8. 43 CFR 3622.1 - Program: General.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) FREE USE OF PETRIFIED WOOD Free Use of Petrified Wood § 3622.1 Program: General. (a) Persons may collect limited quantities of petrified wood for noncommercial... recreational resource. (b) The purchase of petrified wood for commercial purposes is provided for in § 3602.10...

  9. 43 CFR 3622.4 - Collection rules.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) FREE USE OF PETRIFIED WOOD Free Use of Petrified Wood... of petrified wood from public lands using the following criteria: (1) The maximum quantity of petrified wood that any one person is allowed to remove without charge per day is 25 pounds in weight plus...

  10. 43 CFR 3622.4 - Collection rules.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) FREE USE OF PETRIFIED WOOD Free Use of Petrified Wood... of petrified wood from public lands using the following criteria: (1) The maximum quantity of petrified wood that any one person is allowed to remove without charge per day is 25 pounds in weight plus...

  11. 43 CFR 3622.1 - Program: General.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) FREE USE OF PETRIFIED WOOD Free Use of Petrified Wood § 3622.1 Program: General. (a) Persons may collect limited quantities of petrified wood for noncommercial... recreational resource. (b) The purchase of petrified wood for commercial purposes is provided for in § 3602.10...

  12. 43 CFR 3622.4 - Collection rules.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) FREE USE OF PETRIFIED WOOD Free Use of Petrified Wood... of petrified wood from public lands using the following criteria: (1) The maximum quantity of petrified wood that any one person is allowed to remove without charge per day is 25 pounds in weight plus...

  13. 40 CFR 747.115 - Mixed mono and diamides of an organic acid.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... warning statement shall be no smaller than six point type. All required label text shall be of sufficient..., commerce, importer, impurity, Inventory, manufacturer, person, process, processor, and small quantities... control of the processor. (ii) Distribution in commerce is limited to purposes of export. (iii) The...

  14. Lessons from the Top

    ERIC Educational Resources Information Center

    Trachtenberg, Stephen J.

    2007-01-01

    The author, recently retired from a university presidency, offers some lessons he has learned concerning the elusive quality called leadership: (1) Academic bureaucrats at all levels need luck in generous quantities; (2) Try to know as much as possible about your institution; and (3) Administration requires patience. He draws on personal stories…

  15. 40 CFR 747.200 - Triethanolamine salt of tricarboxylic acid.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., person, process, processor, and small quantities solely for research and development have the same... nitrosating agents to this substance leads to formation of a substance known to cause cancer in laboratory.... Addition of nitrite leads to formation of a substance known to cause cancer. This product is designed to be...

  16. 40 CFR 747.200 - Triethanolamine salt of tricarboxylic acid.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., person, process, processor, and small quantities solely for research and development have the same... nitrosating agents to this substance leads to formation of a substance known to cause cancer in laboratory.... Addition of nitrite leads to formation of a substance known to cause cancer. This product is designed to be...

  17. 40 CFR 747.200 - Triethanolamine salt of tricarboxylic acid.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., person, process, processor, and small quantities solely for research and development have the same... nitrosating agents to this substance leads to formation of a substance known to cause cancer in laboratory.... Addition of nitrite leads to formation of a substance known to cause cancer. This product is designed to be...

  18. 40 CFR 747.200 - Triethanolamine salt of tricarboxylic acid.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., person, process, processor, and small quantities solely for research and development have the same... nitrosating agents to this substance leads to formation of a substance known to cause cancer in laboratory.... Addition of nitrite leads to formation of a substance known to cause cancer. This product is designed to be...

  19. Antecedents to Team Performance on Student IT Projects

    ERIC Educational Resources Information Center

    Havelka, Douglas

    2016-01-01

    A study was performed to test the impact of factors suggested by social capital and social cognitive theories as important antecedents to team performance on information technology (IT) course projects. Specifically, the impact of personal outcome expectations and social interaction ties on the quality and quantity of knowledge sharing is…

  20. 17 CFR 32.5 - Disclosure.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... transactions being offered including: (i) The duration of the commodity options being offered and the total quantity and quality of the commodities which may be purchased or sold upon exercise of the options being... PERSON SHOULD NOT PURCHASE A COMMODITY OPTION UNLESS HE IS PREPARED TO SUSTAIN A TOTAL LOSS OF THE...

  1. 30 CFR 75.364 - Weekly examination.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and air quality in the area. Air quantity measurements shall also be made where the air enters and... made where air enters the worked-out area. (ii) Measurements of methane and oxygen concentrations and...) Measurements and tests. At least every 7 days, a certified person shall— (1) Determine the volume of air...

  2. Profiles of Intrinsic and Extrinsic Motivations in Elementary School: A Longitudinal Analysis

    ERIC Educational Resources Information Center

    Corpus, Jennifer Henderlong; Wormington, Stephanie V.

    2014-01-01

    The authors used a person-centered, longitudinal approach to identify and evaluate naturally occurring combinations of intrinsic and extrinsic motivations among 490 third- through fifth-grade students. Cluster analysis revealed 3 groups, characterized by high levels of both motivations ("high quantity"): high intrinsic motivation but low…

  3. 41 CFR 102-35.20 - What definitions apply to GSA's personal property regulations?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... determine its capitalization thresholds as discussed in Financial Accounting Standard Advisory Board (FASAB) Statement of Federal Financial Accounting Standards No. 6 Accounting for Property, Plant and Equipment... an agency, along with a formal process to verify the condition, location, and quantity of such items...

  4. 7 CFR 1434.15 - Personal liability..

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... matters of fact and interest; and (ii) Not remove or dispose of any amount of the loan quantity without... plus charges and interest; and (2) If the producer fails to pay such amount within 30 calendar days... and interest. (e) For liquidated damages assessed in accordance with paragraph (c)(2) of this section...

  5. 43 CFR 3622.1 - Program: General.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) FREE USE OF PETRIFIED WOOD Free Use of Petrified Wood § 3622.1 Program: General. (a) Persons may collect limited quantities of petrified wood for noncommercial... recreational resource. (b) The purchase of petrified wood for commercial purposes is provided for in § 3602.10...

  6. 43 CFR 3622.4 - Collection rules.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) FREE USE OF PETRIFIED WOOD Free Use of Petrified Wood... of petrified wood from public lands using the following criteria: (1) The maximum quantity of petrified wood that any one person is allowed to remove without charge per day is 25 pounds in weight plus...

  7. How to Handle Radioisotopes Safely.

    ERIC Educational Resources Information Center

    Sulcoski, John W.

    This booklet is one in a series of instructional aids designed for use by elementary and secondary school science teachers. The various units and forms of radioactive materials used by teachers are first considered. Then, the quantities of radioisotopes that a person may possess without a license from the Atomic Energy Commission (AEC) are…

  8. 40 CFR 725.205 - Persons who may report under this subpart.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... viable improvement of a product already on the market; or (ii) The researcher has sought or is seeking... microorganism, including as part of a mixture, is processed, distributed in commerce, or used, for any commercial purpose other than research and development. (e) Quantities of the inactivated microorganism, or...

  9. Measles vaccination in the presence or absence of maternal measles antibody: impact on child survival.

    PubMed

    Aaby, Peter; Martins, Cesário L; Garly, May-Lill; Andersen, Andreas; Fisker, Ane B; Claesson, Mogens H; Ravn, Henrik; Rodrigues, Amabelia; Whittle, Hilton C; Benn, Christine S

    2014-08-15

    Measles vaccine (MV) has a greater effect on child survival when administered in early infancy, when maternal antibody may still be present. To test whether MV has a greater effect on overall survival if given in the presence of maternal measles antibody, we reanalyzed data from 2 previously published randomized trials of a 2-dose schedule with MV given at 4-6 months and at 9 months of age. In both trials antibody levels had been measured before early measles vaccination. In trial I (1993-1995), the mortality rate was 0.0 per 1000 person-years among children vaccinated with MV in the presence of maternal antibody and 32.3 per 1000 person-years without maternal antibody (mortality rate ratio [MRR], 0.0; 95% confidence interval [CI], 0-.52). In trial II (2003-2007), the mortality rate was 4.2 per 1000 person-years among children vaccinated in presence of maternal measles antibody and 14.5 per 1000 person-years without measles antibody (MRR, 0.29; 95% CI, .09-.91). Possible confounding factors did not explain the difference. In a combined analysis, children who had measles antibody detected when they received their first dose of MV at 4-6 months of age had lower mortality than children with no maternal antibody, the MRR being 0.22 (95% CI, .07-.64) between 4-6 months and 5 years. Child mortality in low-income countries may be reduced by vaccinating against measles in the presence of maternal antibody, using a 2-dose schedule with the first dose at 4-6 months (earlier than currently recommended) and a booster dose at 9-12 months of age. NCT00168558. © The Author 2014. Published by Oxford University Press on behalf of the Infectious Diseases Society of America.

  10. Estimation of staff lens doses during interventional procedures. Comparing cardiology, neuroradiology and interventional radiology.

    PubMed

    Vano, E; Sanchez, R M; Fernandez, J M

    2015-07-01

    The purpose of this article is to estimate lens doses using over apron active personal dosemeters in interventional catheterisation laboratories (cardiology IC, neuroradiology IN and radiology IR) and to investigate correlations between occupational lens doses and patient doses. Active electronic personal dosemeters placed over the lead apron were used on a sample of 204 IC procedures, 274 IN and 220 IR (all performed at the same university hospital). Patient dose values (kerma area product) were also recorded to evaluate correlations with occupational doses. Operators used the ceiling-suspended screen in most cases. The median and third quartile values of equivalent dose Hp(10) per procedure measured over the apron for IC, IN and IR resulted, respectively, in 21/67, 19/44 and 24/54 µSv. Patient dose values (median/third quartile) were 75/128, 83/176 and 61/159 Gy cm(2), respectively. The median ratios for dosemeters worn over the apron by operators (protected by the ceiling-suspended screen) and patient doses were 0.36; 0.21 and 0.46 µSv Gy(-1) cm(-2), respectively. With the conservative approach used (lens doses estimated from the over apron chest dosemeter) we came to the conclusion that more than 800 procedures y(-1) and per operator were necessary to reach the new lens dose limit for the three interventional specialties. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Individualized texting for adherence building (iTAB): improving antiretroviral dose timing among HIV-infected persons with co-occurring bipolar disorder.

    PubMed

    Moore, David J; Poquette, Amelia; Casaletto, Kaitlin B; Gouaux, Ben; Montoya, Jessica L; Posada, Carolina; Rooney, Alexandra S; Badiee, Jayraan; Deutsch, Reena; Letendre, Scott L; Depp, Colin A; Grant, Igor; Atkinson, J Hampton

    2015-03-01

    HIV+ persons with co-occurring bipolar disorder (HIV+/BD+) have elevated rates of medication nonadherence. We conducted a 30-day randomized controlled trial of a two-way, text messaging system, iTAB (n = 25), compared to an active comparison (CTRL) (n = 25) to improve antiretroviral (ARV) and psychotropic (PSY) adherence and dose timing. Both groups received medication adherence psychoeducation and daily texts assessing mood. The iTAB group additionally received personalized medication reminder texts. Participants responded to over 90 % of the mood and adherence text messages. Mean adherence, as assessed via electronic monitoring caps, was high and comparable between groups for both ARV (iTAB 86.2 % vs. CTRL 84.8 %; p = 0.95, Cliff's d = 0.01) and PSY (iTAB 78.9 % vs. CTRL 77.3 %; p = 0.43, Cliff's d = -0.13) medications. However, iTAB participants took ARVs significantly closer to their intended dosing time than CTRL participants (iTAB: 27.8 vs. CTRL: 77.0 min from target time; p = 0.02, Cliff's d = 0.37). There was no group difference on PSY dose timing. Text messaging interventions may represent a low-burden approach to improving timeliness of medication-taking behaviors among difficult-to-treat populations. The benefits of improved dose timing for long-term medication adherence require additional investigation.

  12. Individualized Texting for Adherence Building (iTAB): Improving Antiretroviral Dose Timing Among HIV-Infected Persons with Co-occurring Bipolar Disorder

    PubMed Central

    Poquette, Amelia; Casaletto, Kaitlin B.; Gouaux, Ben; Montoya, Jessica L.; Posada, Carolina; Rooney, Alexandra S.; Badiee, Jayraan; Deutsch, Reena; Letendre, Scott L.; Depp, Colin A.; Grant, Igor; Atkinson, J. Hampton

    2015-01-01

    HIV+ persons with co-occurring bipolar disorder (HIV+/BD+) have elevated rates of medication nonadherence. We conducted a 30-day randomized controlled trial of a two-way, text messaging system, iTAB (n = 25), compared to an active comparison (CTRL) (n = 25) to improve antiretroviral (ARV) and psychotropic (PSY) adherence and dose timing. Both groups received medication adherence psychoeducation and daily texts assessing mood. The iTAB group additionally received personalized medication reminder texts. Participants responded to over 90 % of the mood and adherence text messages. Mean adherence, as assessed via electronic monitoring caps, was high and comparable between groups for both ARV (iTAB 86.2 % vs. CTRL 84.8 %; p = 0.95, Cliff’s d = 0.01) and PSY (iTAB 78.9 % vs. CTRL 77.3 %; p = 0.43, Cliff’s d = −0.13) medications. However, iTAB participants took ARVs significantly closer to their intended dosing time than CTRL participants (iTAB: 27.8 vs. CTRL: 77.0 min from target time; p = 0.02, Cliff’s d = 0.37). There was no group difference on PSY dose timing. Text messaging interventions may represent a low-burden approach to improving timeliness of medication-taking behaviors among difficult-to-treat populations. The benefits of improved dose timing for long-term medication adherence require additional investigation. PMID:25504449

  13. Oral Cholera Vaccine Coverage during an Outbreak and Humanitarian Crisis, Iraq, 2015.

    PubMed

    Lam, Eugene; Al-Tamimi, Wasan; Russell, Steven Paul; Butt, Muhammad Obaid-Ul Islam; Blanton, Curtis; Musani, Altaf Sadrudin; Date, Kashmira

    2017-01-01

    During November-December 2015, as part of the 2015 cholera outbreak response in Iraq, the Iraqi Ministry of Health targeted ≈255,000 displaced persons >1 year of age with 2 doses of oral cholera vaccine (OCV). All persons who received vaccines were living in selected refugee camps, internally displaced persons camps, and collective centers. We conducted a multistage cluster survey to obtain OCV coverage estimates in 10 governorates that were targeted during the campaign. In total, 1,226 household and 5,007 individual interviews were conducted. Overall, 2-dose OCV coverage in the targeted camps was 87% (95% CI 85%-89%). Two-dose OCV coverage in the 3 northern governorates (91%; 95% CI 87%-94%) was higher than that in the 7 southern and central governorates (80%; 95% CI 77%-82%). The experience in Iraq demonstrates that OCV campaigns can be successfully implemented as part of a comprehensive response to cholera outbreaks among high-risk populations in conflict settings.

  14. Abdominal Pediatric Cancer Surveillance using Serial CT: Evaluation of Organ Absorbed Dose and Effective Dose

    PubMed Central

    Lam, Diana; Wootton-Gorges, Sandra L.; McGahan, John P.; Stern, Robin; Boone, John M.

    2012-01-01

    Computed tomography (CT) is used extensively in cancer diagnosis, staging, evaluation of response to treatment, and in active surveillance for cancer reoccurrence. A review of CT technology is provided, at a level of detail appropriate for a busy clinician to review. The basis of x-ray CT dosimetry is also discussed, and concepts of absorbed dose and effective dose are distinguished. Absorbed dose is a physical quantity (measured in milliGray) equal to the x-ray energy deposited in a mass of tissue, whereas effective dose utilizes an organ-specific weighting method which converts organ doses to effective dose measured in milliSieverts. The organ weighting values carry with them a measure of radiation risk, and so effective dose (in mSv) is not a physical dose metric but rather is one that conveys radiation risk. The use of CT in a cancer surveillance protocol was used as an example of a pediatric patient who had kidney cancer, with surgery and radiation therapy. The active use of CT for cancer surveillance along with diagnostic CT scans led to a total of 50 CT scans performed on this child in a 7 year period. It was estimated that the patient received an average organ dose of 431 mGy from these CT scans. By comparison, the radiation therapy was performed and delivered 50.4 Gy to the patient’s abdomen. Thus, the total dose from CT represented only 0.8% of the patients radiation dose. PMID:21362521

  15. Density of alcohol outlets and teenage drinking: living in an alcogenic environment is associated with higher consumption in a metropolitan setting.

    PubMed

    Huckle, Taisia; Huakau, John; Sweetsur, Paul; Huisman, Otto; Casswell, Sally

    2008-10-01

    This study examines the relationship between physical, socio-economic and social environments and alcohol consumption and drunkenness among a general population sample of drinkers aged 12-17 years. DESIGN, SETTING, PARTICIPANTS AND MEASURES: The study was conducted in Auckland, New Zealand. The design comprised two components: (i) environmental measures including alcohol outlet density, locality-based measure of willingness to sell alcohol (derived from purchase surveys of outlets) and a locality-based neighbourhood deprivation measure calculated routinely in New Zealand (known as NZDEP); and (ii) the second component was a random telephone survey to collect individual-level information from respondents aged 12-17 years including ethnicity, frequency of alcohol supplied socially (by parents, friends and others), young person's income; frequency of exposure to alcohol advertising; recall of brands of alcohol and self-reported purchase from alcohol outlets. A multi-level model was fitted to predict typical-occasion quantity, frequency of drinking and drunkenness in drinkers aged 12-17 years. Typical-occasion quantity was predicted by: frequency of social supply (by parents, friends and others); ethnicity and outlet density; and self-reported purchasing approached significance. NZDEP was correlated highly with outlet density so could not be analysed in the same model. In a separate model, NZDEP was associated with quantity consumed on a typical drinking occasion. Annual frequency was predicted by: frequency of social supply of alcohol, self-reported purchasing from alcohol outlets and ethnicity. Feeling drunk was predicted by frequency of social supply of alcohol, self-reported purchasing from alcohol outlets and ethnicity; outlet density approached significance. Age and gender also had effects in the models, but retailers' willingness to sell to underage patrons had no effects on consumption, nor did the advertising measures. The young person's income was influential on typical-occasion quantity once deprivation was taken into account. Alcohol outlet density was associated with quantities consumed among teenage drinkers in this study, as was neighbourhood deprivation. Supply by family, friends and others also predicted quantities consumed among underage drinkers and both social supply and self-reported purchase were associated with frequency of drinking and drunkenness. The ethnic status of young people also had an effect on consumption.

  16. Drinking and displacement: a systematic review of the influence of forced displacement on harmful alcohol use.

    PubMed

    Weaver, Heather; Roberts, Bayard

    2010-11-01

    This paper systematically reviews evidence about factors associated with harmful alcohol use amongst forcibly displaced persons, including refugees and internally displaced persons. Bibliographic and humanitarian-related databases were searched. The number of quantitative and qualitative studies that were screened and reviewed was 1108. Only 10 studies met inclusion criteria. Risk factors identified included gender, age, exposure to traumatic events and resulting posttraumatic stress disorder, prior alcohol consumption-related problems, year of immigration, location of residence, social relations, and postmigration trauma and stress. The evidence base was extremely weak, and there is a need to improve the quantity and quality of research about harmful alcohol use by forcibly displaced persons.

  17. ALARA database value in future outage work planning and dose management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, D.W.; Green, W.H.

    1995-03-01

    ALARA database encompassing job-specific duration and man-rem plant specific information over three refueling outages represents an invaluable tool for the outage work planner and ALARA engineer. This paper describes dose-management trends emerging based on analysis of three refueling outages at Clinton Power Station. Conclusions reached based on hard data available from a relational database dose-tracking system is a valuable tool for planning of future outage work. The system`s ability to identify key problem areas during a refueling outage is improving as more outage comparative data becomes available. Trends over a three outage period are identified in this paper in themore » categories of number and type of radiation work permits implemented, duration of jobs, projected vs. actual dose rates in work areas, and accuracy of outage person-rem projection. The value of the database in projecting 1 and 5 year station person-rem estimates is discussed.« less

  18. ESR dosimetry for atomic bomb survivors and radiologic technologists

    NASA Astrophysics Data System (ADS)

    Tatsumi-Miyajima, Junko

    1987-06-01

    An individual absorbed dose for atomic bomb (A-bomb) survivors and radiologic technologists has been estimated using a new personal dosimetry. This dosimetry is based on the electron spin resonance (ESR) spectroscopy of the CO 33- radicals, which are produced in their teeth by radiation. Measurements were carried out to study the characteristics of the dosimetry; the ESR signals of the CO 33- radicals were stable and increased linearly with the radiation dose. In the evaluation of the absorbed dose, the ESR signals were considered to be a function of photon energy. The absorbed doses in ten cases of A-bomb victims and eight cases of radiologic technologists were determined. For A-bomb survivors, the adsorbed doses, which were estimated using the ESR dosimetry, were consistent with the ones obtained using the calculations of the tissue dose in air of A-bomb, and also with the ones obtained using the chromosome measurements. For radiologic technologists, the absorbed doses, which were estimated using the ESR dosimetry, agreed with the ones calculated using the information on the occupational history and conditions. The advantages of this method are that the absorbed dose can be directly estimated by measuring the ESR signals obtained from the teeth of persons, who are exposed to radiation. Therefore, the ESR dosimetry is useful to estimate the accidental exposure and the long term cumulative dose.

  19. Exercise quantity-dependent muscle hypertrophy in adult zebrafish (Danio rerio).

    PubMed

    Hasumura, Takahiro; Meguro, Shinichi

    2016-07-01

    Exercise is very important for maintaining and increasing skeletal muscle mass, and is particularly important to prevent and care for sarcopenia and muscle disuse atrophy. However, the dose-response relationship between exercise quantity, duration/day, and overall duration and muscle mass is poorly understood. Therefore, we investigated the effect of exercise duration on skeletal muscle to reveal the relationship between exercise quantity and muscle hypertrophy in zebrafish forced to exercise. Adult male zebrafish were exercised 6 h/day for 4 weeks, 6 h/day for 2 weeks, or 3 h/day for 2 weeks. Flow velocity was adjusted to maximum velocity during continual swimming (initial 43 cm/s). High-speed consecutive photographs revealed that zebrafish mainly drove the caudal part. Additionally, X-ray micro computed tomography measurements indicated muscle hypertrophy of the mid-caudal half compared with the mid-cranial half part. The cross-sectional analysis of the mid-caudal half muscle revealed that skeletal muscle (red, white, or total) mass increased with increasing exercise quantity, whereas that of white muscle and total muscle increased only under the maximum exercise load condition of 6 h/day for 4 weeks. Additionally, the muscle fiver size distributions of exercised fish were larger than those from non-exercised fish. We revealed that exercise quantity, duration/day, and overall duration were correlated with skeletal muscle hypertrophy. The forced exercise model enabled us to investigate the relationship between exercise quantity and skeletal muscle mass. These results open up the possibility for further investigations on the effects of exercise on skeletal muscle in adult zebrafish.

  20. Alpha-particle-induced cancer in humans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mays, C.W.

    Updated information is given on alpha-particle-induced cancer in persons internally exposed to 222Rn progeny, Thorotrast, long-lived 226Ra and 228Ra, and short-lived 224Ra. The lung cancer risk to persons breathing 222Rn progeny in the indoor air of offices, schools, and homes is of increasing concern. About half of the recent deaths among the German Thorotrast patients have been from liver cancer. Animal studies indicate that the liver cancer risk from Thorotrast is mainly from its radioactivity and that the risk coefficient for the Thorotrast patients can be used provisionally for other alpha emitters in the human liver. Six skeletal cancers havemore » occurred in persons with average skeletal doses between 0.85 and 11.8 Gy from 226Ra and 228Ra. In the low-dose German 224Ra patients, two skeletal sarcomas have occurred at about 0.7 Gy compared to about six cases predicted by results from 224Ra patients at higher doses. The minimal appearance time for radiation-induced bone sarcomas in humans is about 4 y. Following brief irradiation, the vast majority of induced bone sarcomas are expressed by about 30 y. Recent evidence against the practical threshold hypothesis is given. With the downward revision of neutron doses to the atomic-bomb survivors, the follow-up of persons exposed to alpha particles may be the best opportunity to evaluate directly the effects of high LET radiation on humans. 90 references.« less

  1. Association of Antidepressant Medications With Incident Type 2 Diabetes Among Medicaid-Insured Youths.

    PubMed

    Burcu, Mehmet; Zito, Julie M; Safer, Daniel J; Magder, Laurence S; dosReis, Susan; Shaya, Fadia T; Rosenthal, Geoffrey L

    2017-12-01

    Antidepressants are one of the most commonly prescribed classes of psychotropic medications among US youths. For adults, there is emerging evidence on the increased risk of type 2 diabetes in association with antidepressant use. However, little is known about the antidepressant treatment-emergent risk of type 2 diabetes among youths. To assess the association between antidepressant use and the risk of incident type 2 diabetes in youths by antidepressant subclass and according to duration of use, cumulative dose, and average daily dose. A retrospective cohort study was conducted using Medicaid claims data from 4 geographically diverse, large states of youths 5 to 20 years of age who initiated antidepressant treatment from January 1, 2005, to December 31, 2009. Antidepressant use (selective serotonin reuptake inhibitors [SSRIs] or serotonin-norepinephrine reuptake inhibitors [SNRIs], tricyclic or other cyclic antidepressants, and other antidepressants) was assessed using the following 4 time-varying measures: current or former use, duration of use, cumulative dose, and average daily dose. Incident type 2 diabetes was assessed using discrete-time failure models, adjusting for disease risk score estimated using more than 125 baseline and time-dependent covariates. In this cohort of 119 608 youths aged 5 to 20 years who initiated antidepressant treatment (59 087 female youths and 60 521 male youths; 54.7% between 5 and 14 years of age) with a mean follow-up of 22.8 months, 79 285 [66.3%] had SSRI or SNRI exposure. The risk of type 2 diabetes was significantly greater during current use than former use of SSRIs or SNRIs (absolute risk, 1.29 per 10 000 person-months vs 0.64 per 10 000 person-months; adjusted relative risk [RR], 1.88; 95% CI, 1.34-2.64) and tricyclic or other cyclic antidepressants (absolute risk, 0.89 per 10 000 person-months vs 0.48 per 10 000 person-months; RR, 2.15; 95% CI, 1.06-4.36), but not of other antidepressants (absolute risk, 1.15 per 10 000 person-months vs 1.12 per 10 000 person-months; RR, 0.99; 95% CI, 0.66-1.50). Furthermore, for youths currently using SSRIs or SNRIs, the risk of type 2 diabetes increased with the duration of use (RR, 2.66; 95% CI, 1.45-4.88 for >210 days and RR, 2.56; 95% CI, 1.29-5.08 for 151-210 days compared with 1-90 days) and with the cumulative dose (RR, 2.44; 95% CI, 1.35-4.43 for >4500 mg and RR, 2.17; 95% CI, 1.07-4.40 for 3001-4500 mg compared with 1-1500 mg in fluoxetine hydrochloride dose equivalents). By contrast, neither the duration nor the cumulative dose of other antidepressants was associated with an increased risk of type 2 diabetes. The risk of type 2 diabetes increased significantly with the average daily dose among youths with more than 150 days of SSRI or SNRI use (RR, 2.39; 95% CI, 1.04-5.52 for >15.0 vs ≤15.0 mg/d) but not among youths with 1 to 150 days of SSRI or SNRI use. In a large cohort of youths insured by Medicaid, the use of SSRIs or SNRIs-the most commonly used antidepressant subclass-was associated with an increased risk of type 2 diabetes that intensified with increasing duration of use, cumulative dose, and average daily dose.

  2. Mutant quantity and quality in mammalian cells (A{sub L}) exposed to cesium-137 gamma radiation: Effect of caffeine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McGuinness, S.M.; Shibuya, M.L.; Ueno, A.M.

    1995-06-01

    We examined the effect of caffeine (1,3,7-trimethylxanthine) on the quantity and quality of mutations in cultured mammalian A{sub L} human-hamster hybrid cells exposed to {sup 137}Cs {gamma} radiation. At a dose (1.5 mg/ml for 16 h) that reduced the plating efficiency (PE) by 20%, caffeine was not itself a significant mutagen, but it increased by approximately twofold the slope of the dose-response curve for induction of S1{sup {minus}} mutants by {sup 137}Cs {gamma} radiation. Molecular analysis of 235 S1{sup {minus}} mutants using a series of DNA probes mapped to the human chromosome 11 in the A{sub L} hybrid cells revealedmore » that 73 to 85% of the mutations in unexposed cells and in cells treated with caffeine alone, {sup 137}Cs {gamma} rays alone or {sup 137}Cs {gamma} rays plus caffeine were large deletions involving millions of base pairs of DNA. Most of these deletions were contiguous with the region of the MIC1 gene at 11p13 that encodes the S1 cell surface antigen. In other mutants that had suffered multiple marker loss, the deletions were intermittent along chromosome 11. These {open_quotes}complex{close_quotes} mutations were rare for {sup 137}Cs {gamma} irradiation (1/63 = 1.5%) but relatively prevalent (23-50%) for other exposure conditions. Thus caffeine appears to alter both the quantity and quality of mutations induced by {sup 137}Cs {gamma} irradiation. 62 refs., 3 figs., 3 tabs.« less

  3. UV irradiation and autoclave treatment for elimination of contaminating DNA from laboratory consumables.

    PubMed

    Gefrides, Lisa A; Powell, Mark C; Donley, Michael A; Kahn, Roger

    2010-02-01

    Laboratories employ various approaches to ensure that their consumables are free of DNA contamination. They may purchase pre-treated consumables, perform quality control checks prior to casework, and use in-house profile databases for contamination detection. It is better to prevent contamination prior to DNA typing than identify it after samples are processed. To this end, laboratories may UV irradiate or autoclave consumables prior to use but treatment procedures are typically based on killing microorganisms and not on the elimination of DNA. We report a systematic study of UV and autoclave treatments on the persistence of DNA from saliva. This study was undertaken to determine the best decontamination strategy for the removal of DNA from laboratory consumables. We have identified autoclave and UV irradiation procedures that can eliminate nanogram quantities of contaminating DNA contained within cellular material. Autoclaving is more effective than UV irradiation because it can eliminate short fragments of contaminating DNA more effectively. Lengthy autoclave or UV irradiation treatments are required. Depending on bulb power, a UV crosslinker may take a minimum of 2h to achieve an effective dose for elimination of nanogram quantities of contaminating DNA (>7250mJ/cm(2)). Similarly autoclaving may also take 2h to eliminate similar quantities of contaminating DNA. For this study, we used dried saliva stains to determine the effective dose. Dried saliva stains were chosen because purified DNA as well as fresh saliva are less difficult to eradicate than dried stains and also because consumable contamination is more likely to be in the form of a collection of dry cells.

  4. Thyroid ultrasound abnormalities in persons exposed during childhood to 131I from the Hanford nuclear site.

    PubMed

    Kopecky, Kenneth J; Onstad, Lynn; Hamilton, Thomas E; Davis, Scott

    2005-06-01

    Approximately 740,000 Ci of 131I were released into the atmosphere from the Hanford Nuclear Site in Washington State during 1944-1957. The Hanford Thyroid Disease Study (HTDS), conducted to determine if thyroid disease is increased among persons exposed as children to that 131I, also investigated whether thyroid ultrasound (US) abnormalities might be increased. The HTDS cohort (n = 5199) was selected from 1940-1946 births to mothers with usual residence in seven Washington counties. Of these, 4350 were located alive, 3447 attended HTDS clinics (1992-1997), and 3440 (1747 females) had evaluable clinical results and sufficient data to characterize their Hanford 131I exposures. US abnormalities were observed in 55.5% of women and 37.4% of men. Thyroid radiation doses from Hanford 131I, which could be estimated for 3191 evaluable participants, ranged from 0.0029 to 2823 mGy (mean, 174 mGy). Estimated dose was not significantly associated with the prevalence of any US abnormality (p = 0.21), US nodules with maximum dimension 5 mm or more (p = 0.64), or average number of US nodules per person (p = 0.80 for nodules with maximum dimension 5 mm or more). These results remained unchanged after accounting for factors that might confound or modify dose-response relationships and for uncertainty of the dose estimates. This study does not support the hypothesis that 131I exposure at Hanford's dose levels and dose rates during infancy and childhood increases the prevalence of adult thyroid US abnormalities.

  5. Commentary 2 to Cox and Little: radiation-induced oncogenic transformation: the interplay between dose, dose protraction, and radiation quality

    NASA Technical Reports Server (NTRS)

    Brenner, D. J.; Hall, E. J.

    1992-01-01

    There is now a substantial body of evidence for end points such as oncogenic transformation in vitro, and carcinogenesis and life shortening in vivo, suggesting that dose protraction leads to an increase in effectiveness relative to a single, acute exposure--at least for radiations of medium linear energy transfer (LET) such as neutrons. Table I contains a summary of the pertinent data from studies in which the effect is seen. [table: see text] This phenomenon has come to be known as the "inverse dose rate effect," because it is in marked contrast to the situation at low LET, where protraction in delivery of a dose of radiation, either by fractionation or low dose rate, results in a decreased biological effect; additionally, at medium and high LET, for radiobiological end points such as clonogenic survival, the biological effectiveness is independent of protraction. The quantity and quality of the published reports on the "inverse dose rate effect" leaves little doubt that the effect is real, but the available evidence indicates that the magnitude of the effect is due to a complex interplay between dose, dose rate, and radiation quality. Here, we first summarize the available data on the inverse dose rate effect and suggest that it follows a consistent pattern in regard to dose, dose rate, and radiation quality; second, we describe a model that predicts these features; and, finally, we describe the significance of the effect for radiation protection.

  6. THERAPY WITH P$sup 32$ IN POLYCYTHEMIA (in German)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Waschulewski, H.; Dorffel, E.W.

    1958-01-01

    Therapy vdth P/sup 32/ is being used more and more in polycythemia vera rubra. There ls no generally valid dosage scheme. Body-weight, blood-pictare and general condition furnish centaln clues. At present, we administer about 0.08 mc/kg body-weight as initial dose adding later, if necessary, further quantities under careful control of the blood-picture. (auth)

  7. Planning Guidance for Response to a Nuclear Detonation

    DTIC Science & Technology

    2009-01-16

    Radiation and Fallout One of the primary outputs from a nuclear explosion is radiation . Intense... on the jet streams and have a low-level global impact. Radiation Injuries and Fallout Health Impacts A nuclear explosion will produce dangerous... radiation dose rates based on the quantity of visible fallout. Therefore, visible fallout may possibly be used as an indicator of a direct radiation

  8. Analysis of Mass Averaged Tissue Doses in CAM, CAF, MAX, and FAX

    NASA Technical Reports Server (NTRS)

    Slaba, Tony C.; Qualls, Garry D.; Clowdsley, Martha S.; Blattnig, Steve R.; Simonsen, Lisa C.; Walker, Steven A.; Singleterry, Robert C.

    2009-01-01

    To estimate astronaut health risk due to space radiation, one must have the ability to calculate exposure-related quantities averaged over specific organs and tissue types. In this study, we first examine the anatomical properties of the Computerized Anatomical Man (CAM), Computerized Anatomical Female (CAF), Male Adult voXel (MAX), and Female Adult voXel (FAX) models by comparing the masses of various tissues to the reference values specified by the International Commission on Radiological Protection (ICRP). Major discrepancies are found between the CAM and CAF tissue masses and the ICRP reference data for almost all of the tissues. We next examine the distribution of target points used with the deterministic transport code HZETRN to compute mass averaged exposure quantities. A numerical algorithm is used to generate multiple point distributions for many of the effective dose tissues identified in CAM, CAF, MAX, and FAX. It is concluded that the previously published CAM and CAF point distributions were under-sampled and that the set of point distributions presented here should be adequate for future studies involving CAM, CAF, MAX, or FAX. It is concluded that MAX and FAX are more accurate than CAM and CAF for space radiation analyses.

  9. Do changes in biomarkers from space radiation reflect dose or risk?

    NASA Astrophysics Data System (ADS)

    Brooks, A.

    The space environment is made up of many different kinds of radiation so that the proper use of biomarkers is essential to estimate radiation risk. This presentation will evaluate differences between biomarkers of dose and risk and demonstrate why they should not be confused following radiation exposures in deep space. Dose is a physical quantity, while risk is a biological quantity. Many examples exist w ereh dose or changes in biomarkers of dose are inappropriately used as predictors of risk. Without information on the biology of the system, the biomarkers of dose provide little help in predicting risk in tissues or radiation exposure types where no excess risk can be demonstrated. Many of these biomarkers of dose only reflect changes in radiation dose or exposure. However, these markers are often incorrectly used to predict risk. For example, exposure of the trachea or of the deep lung to high-LET alpha particles results in similar changes in the biomarker chromosome damage in these two tissues. Such an observation would predict that the risk for cancer induction would be similar in these two tissues. It has been noted , however, that there has never been a tracheal tumor observed in rats that inhaled radon, but with the same exposure, large numbers of tumors were produced in the deep lung. The biology of the different tissues is the major determinant of the risk rather than the radiation dose. Recognition of this fact has resulted in the generation of tissue weighting factors for use in radiation protection. When tissue weighting factors are used the values derived are still called "dose". It is important to recognize that tissue specific observations have been corrected to reflect risk, and therefore should no longer be viewed as dose. The relative biological effectiveness (RBE) is also used to estimate radiation risk. The use of biomarkers to derive RBE is a difficult since it involves the use of a biological response to a standard low-LET reference radiation. Following low-LET radiation exposure, the biological response often does not increase as a linear function of dose. Thus, the RBE and the subsequent risk predicted is dependent on the dose where the two radiation types are compared. To avoid this problem the standard procedure is to use the dose and dose-rate response and compare the linear components of the two r diation exposures. Important riska comparisons are often done at very low doses, where the reference radiation may either increase or decrease as a function of dose. Since the low-LET exposure often does not produce a significant change above the background level of damage, the derived RBE factors can become very large.Studies using micronuclei as biomarkers following exposure to mono-energetic neutrons, x-rays and gamma rays delivered at very low doses (up to 0.10 Gy) demonstrated the differences in the shape of each dose-response relationship and the problems associated with the RBE. These studies show that RBE may not accurately reflect the hazards or risk associated with space radiation exposure. As additional measures of biological change are developed, it may become possible to base risk on biological change and not on changes in radiation doses. Research funded through grants # DE-FG03-99ER62787 from DOE Office of Biological and Environmental Research and RO1 CA74053-01 from NIH/NASA to Washington State University Tri-Cities.

  10. The Relationship between Distributed Leadership and Principal's Leadership Effectiveness in North Carolina

    ERIC Educational Resources Information Center

    Grant, Carl P.

    2011-01-01

    As principals' responsibilities increase in quantity and complexity along with accountability demands for improved student achievement, some researchers argue that one person can no longer successfully lead a school; rather schools should be led in a collaborative manner with school staff members in shared decision-making through a distributed…

  11. 7 CFR 6.22 - Requirement for a license.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... obtained prior to entry, and the importer of record (or a broker or agent acting on its behalf) shall... documentation identifying the article, quantity to be imported, its location, intended use, an entry number and... article be destroyed or re-exported after such use; or (4) Such person pays the applicable over-quota rate...

  12. 7 CFR 6.22 - Requirement for a license.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... obtained prior to entry, and the importer of record (or a broker or agent acting on its behalf) shall... documentation identifying the article, quantity to be imported, its location, intended use, an entry number and... article be destroyed or re-exported after such use; or (4) Such person pays the applicable over-quota rate...

  13. 7 CFR 6.22 - Requirement for a license.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... obtained prior to entry, and the importer of record (or a broker or agent acting on its behalf) shall... documentation identifying the article, quantity to be imported, its location, intended use, an entry number and... article be destroyed or re-exported after such use; or (4) Such person pays the applicable over-quota rate...

  14. 7 CFR 6.22 - Requirement for a license.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... obtained prior to entry, and the importer of record (or a broker or agent acting on its behalf) shall... documentation identifying the article, quantity to be imported, its location, intended use, an entry number and... article be destroyed or re-exported after such use; or (4) Such person pays the applicable over-quota rate...

  15. 7 CFR 6.22 - Requirement for a license.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... obtained prior to entry, and the importer of record (or a broker or agent acting on its behalf) shall... documentation identifying the article, quantity to be imported, its location, intended use, an entry number and... article be destroyed or re-exported after such use; or (4) Such person pays the applicable over-quota rate...

  16. Sex Differences in Appropriateness of Communication through Multiple Nonverbal Channels.

    ERIC Educational Resources Information Center

    Strube, Michael J.; Werner, Carol

    A study investigated the use of nonverbal cues by male and female subjects during relatively pleasant and unpleasant interactions. Five nonverbal behaviors found to be effective in controlling both the quantity and the quality of interactions were examined: gaze, smiling, arm position, interpersonal distance, and personal space. It was expected…

  17. Creating Rich Portraits: A Mixed-Methods Approach to Understanding Profiles of Intrinsic and Extrinsic Motivations

    ERIC Educational Resources Information Center

    Corpus, Jennifer Henderlong; Wormington, Stephanie V.; Haimovitz, Kyla

    2016-01-01

    A person-centered, mixed-methods approach (self-report surveys, semistructured interviews, school records) was used to characterize and evaluate profiles of intrinsic and extrinsic motivations among 243 third- through eighth-grade students. Cluster analysis suggested four distinct profiles: high quantity (high intrinsic, high extrinsic), primarily…

  18. Information Technology Planning: Computers in the School Library--How Many Are Enough?

    ERIC Educational Resources Information Center

    Simpson, Carol

    2002-01-01

    Describes the development of a formula to determine the needed quantity of computers for a school library. Four types of information technology activities (administrative, personal productive, class/group productive, online public access catalog) and several variables (age levels served, campus focus, number of staff, size of student body, average…

  19. Corpus Linguistics for Korean Language Learning and Teaching. NFLRC Technical Report No. 26

    ERIC Educational Resources Information Center

    Bley-Vroman, Robert, Ed.; Ko, Hyunsook, Ed.

    2006-01-01

    Dramatic advances in personal computer technology have given language teachers access to vast quantities of machine-readable text, which can be analyzed with a view toward improving the basis of language instruction. Corpus linguistics provides analytic techniques and practical tools for studying language in use. This volume includes both an…

  20. 49 CFR 175.75 - Quantity limitations and cargo location.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... hazardous material may be loaded in an inaccessible manner. Loaded in an inaccessible manner means cargo that is loaded in such a manner that a crew member or other authorized person cannot handle, and when... loaded in an inaccessible manner. These requirements do not apply to Class 9 and ORM-D materials. (d...

  1. 27 CFR 20.100 - General.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... TREASURY LIQUORS DISTRIBUTION AND USE OF DENATURED ALCOHOL AND RUM Formulas and Statements of Process... maximum quantity that may be sold to any person at one time; or (3) Restrict the sale of an article to a specific class of vendee and for a specific use. (b) Approval by the appropriate TTB officer of formulas...

  2. 27 CFR 20.100 - General.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... TREASURY LIQUORS DISTRIBUTION AND USE OF DENATURED ALCOHOL AND RUM Formulas and Statements of Process... maximum quantity that may be sold to any person at one time; or (3) Restrict the sale of an article to a specific class of vendee and for a specific use. (b) Approval by the appropriate TTB officer of formulas...

  3. 27 CFR 20.100 - General.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... TREASURY LIQUORS DISTRIBUTION AND USE OF DENATURED ALCOHOL AND RUM Formulas and Statements of Process... maximum quantity that may be sold to any person at one time; or (3) Restrict the sale of an article to a specific class of vendee and for a specific use. (b) Approval by the appropriate TTB officer of formulas...

  4. 27 CFR 20.100 - General.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... TREASURY ALCOHOL DISTRIBUTION AND USE OF DENATURED ALCOHOL AND RUM Formulas and Statements of Process... maximum quantity that may be sold to any person at one time; or (3) Restrict the sale of an article to a specific class of vendee and for a specific use. (b) Approval by the appropriate TTB officer of formulas...

  5. 27 CFR 20.100 - General.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... TREASURY ALCOHOL DISTRIBUTION AND USE OF DENATURED ALCOHOL AND RUM Formulas and Statements of Process... maximum quantity that may be sold to any person at one time; or (3) Restrict the sale of an article to a specific class of vendee and for a specific use. (b) Approval by the appropriate TTB officer of formulas...

  6. 21 CFR 1313.12 - Requirement of authorization to import.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... EXPORTATION OF LIST I AND LIST II CHEMICALS Importation of Listed Chemicals § 1313.12 Requirement of authorization to import. (a) Each regulated person who imports a listed chemical that meets or exceeds the threshold quantities identified in § 1310.04(f) or is a listed chemical for which no threshold has been...

  7. 21 CFR 1313.12 - Requirement of authorization to import.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... EXPORTATION OF LIST I AND LIST II CHEMICALS Importation of Listed Chemicals § 1313.12 Requirement of authorization to import. (a) Each regulated person who imports a listed chemical that meets or exceeds the threshold quantities identified in § 1310.04(f) or is a listed chemical for which no threshold has been...

  8. 21 CFR 1313.12 - Requirement of authorization to import.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... EXPORTATION OF LIST I AND LIST II CHEMICALS Importation of Listed Chemicals § 1313.12 Requirement of authorization to import. (a) Each regulated person who imports a listed chemical that meets or exceeds the threshold quantities identified in § 1310.04(f) or is a listed chemical for which no threshold has been...

  9. Media Environment as a Zone of Personal and Social Risk

    ERIC Educational Resources Information Center

    Medvedeva, Tatyana; Kazantseva, Galina; Karpukova, Albina; Serova, Olga; Sizova, Olga; Bikteeva, Lolita

    2016-01-01

    The paper considers elements of modern media environment taking more and more space in day-to-day life of people. The modern media environment enriched with various informational and technological resources, information transfer speed and availability of all kinds of content in unlimited quantities, requires careful examination--first of all,…

  10. [Interaction of a causative agent with associative bacteria during salmonellosis].

    PubMed

    Bukharin, O V; Valyshev, A V; Ivanova, E V; Chaĭnikova, I N; Perunova, N B

    2008-01-01

    To determine a composition of gut microflora during salmonellosis and to study the modification of persistent characteristics (antilysozyme activity, ALA) of symbiotic microorganisms in associations. Bacteriologic study of feces was performed in 90 patients aged 18-39 years, which were divided to three groups: patients with salmonellosis in acute phase, reconvalescent patients, and conditionally healthy persons. Condition of gut microflorawas determined; microorganisms associated with Salmonella infection were isolated, and their influence on ALA of Salmonella was studied. Gut microbiocenosis was more diverse in patients compared with healthy persons. Significant reduction of bifidobacteria quantity (to 10(7) CFU/g of feces and less), especially in reconvalescent period, was noted. Association between bifidoflora deficiency and excessive increase of quantity of yeast fungi was revealed. It was determined that exometabolites of indigenous anaerobic microflora (bifidobacteria) promoted decrease of ALA of Salmonella, whereas opportunistic facultatively anaerobic microorganisms (enterobacteria, staphylococci) rendered mainly stimulating effect on the ALA of Salmonella. Obtained data reveal characteristics of bacterial interactions in associative symbiosis and provide insights about mechanisms of formation of pathobiocenosis and state of bacterial carriage.

  11. Distribution of human waste samples in relation to sizing waste processing in space

    NASA Technical Reports Server (NTRS)

    Parker, Dick; Gallagher, S. K.

    1992-01-01

    Human waste processing for closed ecological life support systems (CELSS) in space requires that there be an accurate knowledge of the quantity of wastes produced. Because initial CELSS will be handling relatively few individuals, it is important to know the variation that exists in the production of wastes rather than relying upon mean values that could result in undersizing equipment for a specific crew. On the other hand, because of the costs of orbiting equipment, it is important to design the equipment with a minimum of excess capacity because of the weight that extra capacity represents. A considerable quantity of information that had been independently gathered on waste production was examined in order to obtain estimates of equipment sizing requirements for handling waste loads from crews of 2 to 20 individuals. The recommended design for a crew of 8 should hold 34.5 liters per day (4315 ml/person/day) for urine and stool water and a little more than 1.25 kg per day (154 g/person/day) of human waste solids and sanitary supplies.

  12. Lack of Response in an Autistic Population to a Low Dose Clinical Trial of Pyridoxine Plus Magnesium.

    ERIC Educational Resources Information Center

    Tolbert, Lelland; And Others

    1993-01-01

    As some therapeutic benefits for autistic persons have been reported from combined high doses of pyridoxine and magnesium, this study evaluated long-term administration of low doses (to minimize adverse effects) to 15 subjects with autism. Findings indicated that, at this dosage level, pyridoxine and magnesium had no effect on the severity of…

  13. Oral drug delivery in personalized medicine: unmet needs and novel approaches.

    PubMed

    Wening, Klaus; Breitkreutz, Jörg

    2011-02-14

    Increasing knowledge into personalized medicine has demonstrated the need for individual dosing. Drug dosage forms are urgently needed enabling an individual therapy, especially for oral drug delivery. This review is focusing on approaches for solid and liquid oral dosage forms for individual dosing. The proposed dosage forms and devices may be distinguished into assembling and partition concepts and have been categorized regarding their applicability, costs, dose flexibility and potential benefits. Opportunities, challenges and further unmet needs are elaborated and critically discussed. Liquid dosage forms can be accurately dosed by novel dropping tubes or oral syringes, but less precisely by dosing spoons and cups. Breaking scored tablets into fragments show major risks such as inaccurate dosing, formation of potent dust and stability issues of the residual segments. Novel approaches are proposed for solid dosage forms enabling a flexible and appropriate therapy such as various dispensers for multiparticulate drug formulations. However, most of the proposals still have to prove their applicability in practice. Promising concepts are the solid dosage pen and drug-loaded oral films which can be cut in individual sections enabling freely selectable doses. Further research and development are required for novel dosage forms and medical devices appropriate for individualized therapy. Copyright © 2010 Elsevier B.V. All rights reserved.

  14. Nanogram quantities of a DNA vaccine protect rainbow trout fry against heterologous strains of infectious hematopoietic necrosis virus

    USGS Publications Warehouse

    Corbeil, S.; LaPatra, S.E.; Anderson, E.D.; Kurath, G.

    2000-01-01

    The efficacy of a DNA vaccine containing the glycoprotein gene of infectious hematopoietic necrosis virus (IHNV), a rhabdovirus affecting trout and salmon, was investigated. The minimal dose of vaccine required, the protection against heterologous strains, and the titers of neutralizing antibodies produced were used to evaluate the potential of the vaccine as a control pharmaceutical. Results indicated that a single dose of as little as 1–10 ng of vaccine protected rainbow trout fry against waterborne challenge by IHNV. An optimal dose of 100 ng per fish was selected to assure strong protection under various conditions. Neutralizing antibody titers were detected in fish vaccinated with concentrations of DNA ranging from 5 to 0.01 μg. Furthermore, the DNA vaccine protected fish against a broad range of viral strains from different geographic locations, including isolates from France and Japan, suggesting that the vaccine could be used worldwide. A single dose of this DNA vaccine induced protection in fish at a lower dose than is usually reported in mammalian DNA vaccine studies.

  15. The relationship between carbohydrate and the mealtime insulin dose in type 1 diabetes.

    PubMed

    Bell, Kirstine J; King, Bruce R; Shafat, Amir; Smart, Carmel E

    2015-01-01

    A primary focus of the nutritional management of type 1 diabetes has been on matching prandial insulin therapy with carbohydrate amount consumed. Different methods exist to quantify carbohydrate including counting in one gram increments, 10g portions or 15g exchanges. Clinicians have assumed that counting in one gram increments is necessary to precisely dose insulin and optimize postprandial control. Carbohydrate estimations in portions or exchanges have been thought of as inadequate because they may result in less precise matching of insulin dose to carbohydrate amount. However, studies examining the impact of errors in carbohydrate quantification on postprandial glycemia challenge this commonly held view. In addition it has been found that a single mealtime bolus of insulin can cover a range of carbohydrate intake without deterioration in postprandial control. Furthermore, limitations exist in the accuracy of the nutrition information panel on a food label. This article reviews the relationship between carbohydrate quantity and insulin dose, highlighting limitations in the evidence for a linear association. These insights have significant implications for patient education and mealtime insulin dose calculations. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Experimental determination of particle range and dose distribution in thick targets through fragmentation reactions of stable heavy ions.

    PubMed

    Inaniwa, Taku; Kohno, Toshiyuki; Tomitani, Takehiro; Urakabe, Eriko; Sato, Shinji; Kanazawa, Mitsutaka; Kanai, Tatsuaki

    2006-09-07

    In radiation therapy with highly energetic heavy ions, the conformal irradiation of a tumour can be achieved by using their advantageous features such as the good dose localization and the high relative biological effectiveness around their mean range. For effective utilization of such properties, it is necessary to evaluate the range of incident ions and the deposited dose distribution in a patient's body. Several methods have been proposed to derive such physical quantities; one of them uses positron emitters generated through projectile fragmentation reactions of incident ions with target nuclei. We have proposed the application of the maximum likelihood estimation (MLE) method to a detected annihilation gamma-ray distribution for determination of the range of incident ions in a target and we have demonstrated the effectiveness of the method with computer simulations. In this paper, a water, a polyethylene and a polymethyl methacrylate target were each irradiated with stable (12)C, (14)N, (16)O and (20)Ne beams. Except for a few combinations of incident beams and targets, the MLE method could determine the range of incident ions R(MLE) with a difference between R(MLE) and the experimental range of less than 2.0 mm under the circumstance that the measurement of annihilation gamma rays was started just after the irradiation of 61.4 s and lasted for 500 s. In the process of evaluating the range of incident ions with the MLE method, we must calculate many physical quantities such as the fluence and the energy of both primary ions and fragments as a function of depth in a target. Consequently, by using them we can obtain the dose distribution. Thus, when the mean range of incident ions is determined with the MLE method, the annihilation gamma-ray distribution and the deposited dose distribution can be derived simultaneously. The derived dose distributions in water for the mono-energetic heavy-ion beams of four species were compared with those measured with an ionization chamber. The good agreement between the derived and the measured distributions implies that the deposited dose distribution in a target can be estimated from the detected annihilation gamma-ray distribution with a positron camera.

  17. Cumulative effective dose associated with radiography and CT of adolescents with spinal injuries.

    PubMed

    Lemburg, Stefan P; Peters, Soeren A; Roggenland, Daniela; Nicolas, Volkmar; Heyer, Christoph M

    2010-12-01

    The purpose of this study was to analyze the quantity and distribution of cumulative effective doses in diagnostic imaging of adolescents with spinal injuries. At a level 1 trauma center from July 2003 through June 2009, imaging procedures during initial evaluation and hospitalization and after discharge of all patients 10-20 years old with spinal fractures were retrospectively analyzed. The cumulative effective doses for all imaging studies were calculated, and the doses to patients with spinal injuries who had multiple traumatic injuries were compared with the doses to patients with spinal injuries but without multiple injuries. The significance level was set at 5%. Imaging studies of 72 patients (32 with multiple injuries; average age, 17.5 years) entailed a median cumulative effective dose of 18.89 mSv. Patients with multiple injuries had a significantly higher total cumulative effective dose (29.70 versus 10.86 mSv, p < 0.001) mainly owing to the significantly higher CT-related cumulative effective dose to multiple injury patients during the initial evaluation (18.39 versus 2.83 mSv, p < 0.001). Overall, CT accounted for 86% of the total cumulative effective dose. Adolescents with spinal injuries receive a cumulative effective dose equal to that of adult trauma patients and nearly three times that of pediatric trauma patients. Areas of focus in lowering cumulative effective dose should be appropriate initial estimation of trauma severity and careful selection of CT scan parameters.

  18. Sociocultural dimensions of supply and demand for natural aggregate; examples from the Mid-Atlantic region, United States

    USGS Publications Warehouse

    Robinson, Gilpin R.; Brown, William M.

    2002-01-01

    The United States uses large quantities of natural aggregate to build and maintain a continuously expanding infrastructure. In recent years, per capita demand for aggregate in the United States has grown to about 9.7 metric tons (10.7 tons) per person per year. Over the next 25 years, the aggregate industry expects to mine quantities equivalent to all aggregate mined in the United States over the past 100 years. The issues surrounding supply and demand for aggregate in the mid-Atlantic states of Maryland, Pennsylvania, Virginia, and West Virginia illustrate competing requirements for industrial minerals and many simultaneous social and environmental objectives.

  19. Will X-ray Safety Glasses Become Mandatory for Radiological Vascular Interventions?

    PubMed

    Thomas, Rohit Philip; Grau, Mathias; Eldergash, Osama; Kowald, Tobias; Schnabel, Johannes; Szczechowicz, Marcin; Chavan, Ajay

    2018-07-01

    The annual permissible radiation ocular lens dose has been reduced to 20 millisieverts (mSv) in the current European directive 2013/59/Euratom. The aim of this study was to evaluate the personal radiation dose for vascular interventions with special focus on ocular lens dose. From May 2016 to October 2016, the personal radiation doses of two interventionists and four technicians were prospectively recorded during 206 vascular interventions. The position of personnel, intervention type and fluoroscopy time were recorded. Parameters evaluated were total body dose measured by film dosimeter, hand dose measured by ring thermoluminescent dosimeter (TLD) and ocular lens dose measured by TLD placed in front of the safety glasses. Linear regression analysis was used to estimate the dose at 2 and 5 years. The ocular lens dose, hand and total body dose of the two interventionists were 11/5, 56/47 and 0.6 mSv each, respectively. The estimated 5-year ocular dose was 113.08 mSv (95% CI 38.2-187.97)/40.95 (95% CI 16.9-64.7). Similarly, hand dose was 608.4 mSv (95% CI 442.78-774.38)/514.47 (95% CI 329.83-699.10) and body dose 6.07 mSv (95% CI 4.70-8.22)/5.12 (95% CI 3.65-6.59), respectively. Amongst four technicians, only the first assistant showed recordings of 0.3 mSv body dose, 2 mSv ocular lens dose and 5 mSv hand dose. The yearly ocular lens dose, particularly for interventionists dealing with complex interventions, could cross the permitted yearly limit set by the new Euratom directive. Therefore, X-ray safety glasses would become mandatory for complex radiological vascular interventions. Level III, non-randomized controlled cohort/follow-up study.

  20. Active personal radiation monitor for lunar EVA

    NASA Astrophysics Data System (ADS)

    Straume, Tore; Borak, Tom; Braby, L. A.; Lusby, Terry; Semones, Edward J.; Vazquez, Marcelo E.

    As astronauts return to the Moon-and this time, work for extended periods-there will be a critical need for crew personnel radiation monitoring as they operate lunar rovers or otherwise perform a myriad of extravehicular activities (EVAs). Our focus is on development of a small personal radiation monitor for lunar EVA that responds to the complex radiation quality and changing dose rates on the Moon. Of particular concern are active monitoring capabilities that provide both early warning and radiation dosimetry information during solar particle events (SPEs). To accomplish this, we are developing small detectors integrated with modern high speed, low power microelectronics to measure dose-rate and dose-mean lineal energy in real time. The monitor is designed to perform over the range of dose rates and LETs expected from both GCR and SPE radiations during lunar EVA missions. The monitor design provides simultaneous measurement of dose-equivalent rates at two tissue-equivalent depths simulating skin and marrow. The compact personal monitor is estimated to be the size of a cell phone and would fit on an EVA spacesuit (e.g., in backpack) or in a toolbox. The four-year development effort (which began December 2007) will result in a prototype radiation monitor field tested and characterized for the major radiations expected on the surface of the Moon. We acknowledge support from NSBRI through grants to NASA Ames Research Center (T. Straume, PI) and Colorado State University (T. Borak, PI).

  1. Measurements of zinc absorption: application and interpretation in research designed to improve human zinc nutriture.

    PubMed

    Hambidge, K Michael; Miller, Leland V; Tran, Cuong D; Krebs, Nancy F

    2005-11-01

    The focus of this paper is on the application of measurements of zinc absorption in human research, especially studies designed to assess the efficacy of intervention strategies to prevent and manage zinc deficiency in populations. Emphasis is given to the measurement of quantities of zinc absorbed rather than restricting investigations to measurements of fractional absorption of zinc. This is especially important when determining absorption of zinc from the diet, whether it be the habitual diet or an intervention diet under evaluation. Moreover, measurements should encompass all meals for a minimum of one day with the exception of some pilot studies. Zinc absorption is primarily via an active saturable transport process into the enterocytes of the proximal small intestine. The relationship between quantity of zinc absorbed and the quantity ingested is best characterized by saturable binding models. When applied to human studies that have sufficient data to examine dose-response relationships, efficiency of absorption is high until approximately 50-60% maximal absorption is achieved, even with moderate phytate intakes. This also coincides approximately with the quantity of absorbed zinc necessary to meet physiologic requirements. Efficiency of absorption with intakes that exceed this level is low or very low. These observations have important practical implications for the design and interpretation of intervention studies to prevent zinc deficiency. They also suggest the potential utility of measurements of the quantity of zinc absorbed when evaluating the zinc status of populations.

  2. Effects of Dietary Protein Source and Quantity during Weight Loss on Appetite, Energy Expenditure, and Cardio-Metabolic Responses.

    PubMed

    Li, Jia; Armstrong, Cheryl L H; Campbell, Wayne W

    2016-01-26

    Higher protein meals increase satiety and the thermic effect of feeding (TEF) in acute settings, but it is unclear whether these effects remain after a person becomes acclimated to energy restriction or a given protein intake. This study assessed the effects of predominant protein source (omnivorous, beef/pork vs. lacto-ovo vegetarian, soy/legume) and quantity (10%, 20%, or 30% of energy from protein) on appetite, energy expenditure, and cardio-metabolic indices during energy restriction (ER) in overweight and obese adults. Subjects were randomly assigned to one protein source and then consumed diets with different quantities of protein (4 weeks each) in a randomized crossover manner. Perceived appetite ratings (free-living and in-lab), TEF, and fasting cardio-metabolic indices were assessed at the end of each 4-week period. Protein source and quantity did not affect TEF, hunger, or desire to eat, other than a modestly higher daily composite fullness rating with 30% vs. 10% protein diet (p = 0.03). While the 20% and 30% protein diets reduced cholesterol, triacylglycerol, and APO-B vs. 10% protein (p < 0.05), protein source did not affect cardio-metabolic indices. In conclusion, diets varying in protein quantity with either beef/pork or soy/legume as the predominant source have minimal effects on appetite control, energy expenditure and cardio-metabolic risk factors during ER-induced weight loss.

  3. A randomized phase II trial of personalized peptide vaccine plus low dose estramustine phosphate (EMP) versus standard dose EMP in patients with castration resistant prostate cancer.

    PubMed

    Noguchi, Masanori; Kakuma, Tatsuyuki; Uemura, Hirotsugu; Nasu, Yasutomo; Kumon, Hiromi; Hirao, Yasuhiko; Moriya, Fukuko; Suekane, Shigetaka; Matsuoka, Kei; Komatsu, Nobukazu; Shichijo, Shigeki; Yamada, Akira; Itoh, Kyogo

    2010-07-01

    Personalized peptide vaccination (PPV) combined with chemotherapy could be a novel approach for many cancer patients. In this randomized study, we evaluated the anti-tumor effect and safety of PPV plus low-dose estramustine phosphate (EMP) as compared to standard-dose EMP for HLA-A2- or -A24-positive patients with castration resistant prostate cancer. Patients were randomized into groups receiving either PPV plus low-dose EMP (280 mg/day) or standard-dose EMP (560 mg/day). After disease progression, patients were switched to the opposite regime. The primary end point was progression-free survival (PFS). We randomly assigned 28 patients to receive PPV plus low-dose EMP and 29 patients to receive standard-dose EMP. Nineteen events in the PPV group and 20 events in the EMP group occurred during the first treatment. Median PFS for the first treatment was 8.5 months in the PPV group and 2.8 months in the EMP group with a hazard ratio (HR) of 0.28 (95% CI, 0.14-0.61; log-rank P = 0.0012), while there was no difference for median PFS for the second treatment. The HR for overall survival was 0.3 (95% CI, 0.1-0.91) in favor of the PPV plus low-dose EMP group (log-rank, P = 0.0328). The PPV plus low-dose EMP was well tolerated without major adverse effects and with increased levels of IgG and cytotoxic-T cell responses to the vaccinated peptides. PPV plus low-dose EMP was associated with an improvement in PSA-based PFS as compared to the standard-dose EMP alone.

  4. Pharmacometric Approaches to Personalize Use of Primarily Renally Eliminated Antibiotics in Preterm and Term Neonates.

    PubMed

    Wilbaux, Mélanie; Fuchs, Aline; Samardzic, Janko; Rodieux, Frédérique; Csajka, Chantal; Allegaert, Karel; van den Anker, Johannes N; Pfister, Marc

    2016-08-01

    Sepsis remains a major cause of mortality and morbidity in neonates, and, as a consequence, antibiotics are the most frequently prescribed drugs in this vulnerable patient population. Growth and dynamic maturation processes during the first weeks of life result in large inter- and intrasubject variability in the pharmacokinetics (PK) and pharmacodynamics (PD) of antibiotics. In this review we (1) summarize the available population PK data and models for primarily renally eliminated antibiotics, (2) discuss quantitative approaches to account for effects of growth and maturation processes on drug exposure and response, (3) evaluate current dose recommendations, and (4) identify opportunities to further optimize and personalize dosing strategies of these antibiotics in preterm and term neonates. Although population PK models have been developed for several of these drugs, exposure-response relationships of primarily renally eliminated antibiotics in these fragile infants are not well understood, monitoring strategies remain inconsistent, and consensus on optimal, personalized dosing of these drugs in these patients is absent. Tailored PK/PD studies and models are useful to better understand relationships between drug exposures and microbiological or clinical outcomes. Pharmacometric modeling and simulation approaches facilitate quantitative evaluation and optimization of treatment strategies. National and international collaborations and platforms are essential to standardize and harmonize not only studies and models but also monitoring and dosing strategies. Simple bedside decision tools assist clinical pharmacologists and neonatologists in their efforts to fine-tune and personalize the use of primarily renally eliminated antibiotics in term and preterm neonates. © 2016, The American College of Clinical Pharmacology.

  5. RADTRAD: A simplified model for RADionuclide Transport and Removal And Dose estimation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Humphreys, S.L.; Miller, L.A.; Monroe, D.K.

    1998-04-01

    This report documents the RADTRAD computer code developed for the U.S. Nuclear Regulatory Commission (NRC) Office of Nuclear Reactor Regulation (NRR) to estimate transport and removal of radionuclides and dose at selected receptors. The document includes a users` guide to the code, a description of the technical basis for the code, the quality assurance and code acceptance testing documentation, and a programmers` guide. The RADTRAD code can be used to estimate the containment release using either the NRC TID-14844 or NUREG-1465 source terms and assumptions, or a user-specified table. In addition, the code can account for a reduction in themore » quantity of radioactive material due to containment sprays, natural deposition, filters, and other natural and engineered safety features. The RADTRAD code uses a combination of tables and/or numerical models of source term reduction phenomena to determine the time-dependent dose at user-specified locations for a given accident scenario. The code system also provides the inventory, decay chain, and dose conversion factor tables needed for the dose calculation. The RADTRAD code can be used to assess occupational radiation exposures, typically in the control room; to estimate site boundary doses; and to estimate dose attenuation due to modification of a facility or accident sequence.« less

  6. Validating Fricke dosimetry for the measurement of absorbed dose to water for HDR 192Ir brachytherapy: a comparison between primary standards of the LCR, Brazil, and the NRC, Canada.

    PubMed

    Salata, Camila; David, Mariano Gazineu; de Almeida, Carlos Eduardo; El Gamal, Islam; Cojocaru, Claudiu; Mainegra-Hing, Ernesto; McEwen, Malcom

    2018-04-05

    Two Fricke-based absorbed dose to water standards for HDR Ir-192 dosimetry, developed independently by the LCR in Brazil and the NRC in Canada have been compared. The agreement in the determination of the dose rate from a HDR Ir-192 source at 1 cm in a water phantom was found to be within the k  =  1 combined measurement uncertainties of the two standards: D NRC /D LCR   =  1.011, standard uncertainty  =  2.2%. The dose-based standards also agreed within the uncertainties with the manufacturer's stated dose rate value, which is traceable to a national standard of air kerma. A number of possible influence quantities were investigated, including the specific method for producing the ferrous-sulphate Fricke solution, the geometry of the holder, and the Monte Carlo code used to determine correction factors. The comparison highlighted the lack of data on the determination of G(Fe 3+ ) in this energy range and the possibilities for further development of the holders used to contain the Fricke solution. The comparison also confirmed the suitability of Fricke dosimetry for Ir-192 primary standard dose rate determinations at therapy dose levels.

  7. Validating Fricke dosimetry for the measurement of absorbed dose to water for HDR 192Ir brachytherapy: a comparison between primary standards of the LCR, Brazil, and the NRC, Canada

    NASA Astrophysics Data System (ADS)

    Salata, Camila; Gazineu David, Mariano; de Almeida, Carlos Eduardo; El Gamal, Islam; Cojocaru, Claudiu; Mainegra-Hing, Ernesto; McEwen, Malcom

    2018-04-01

    Two Fricke-based absorbed dose to water standards for HDR Ir-192 dosimetry, developed independently by the LCR in Brazil and the NRC in Canada have been compared. The agreement in the determination of the dose rate from a HDR Ir-192 source at 1 cm in a water phantom was found to be within the k  =  1 combined measurement uncertainties of the two standards: D NRC/D LCR  =  1.011, standard uncertainty  =  2.2%. The dose-based standards also agreed within the uncertainties with the manufacturer’s stated dose rate value, which is traceable to a national standard of air kerma. A number of possible influence quantities were investigated, including the specific method for producing the ferrous-sulphate Fricke solution, the geometry of the holder, and the Monte Carlo code used to determine correction factors. The comparison highlighted the lack of data on the determination of G(Fe3+) in this energy range and the possibilities for further development of the holders used to contain the Fricke solution. The comparison also confirmed the suitability of Fricke dosimetry for Ir-192 primary standard dose rate determinations at therapy dose levels.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, C

    Purpose: To implement a novel, automatic, institutional customizable DVH quantities evaluation and PDF report tool on Philips Pinnacle treatment planning system (TPS) Methods: An add-on program (P3DVHStats) is developed by us to enable automatic DVH quantities evaluation (including both volume and dose based quantities, such as V98, V100, D2), and automatic PDF format report generation, for EMR convenience. The implementation is based on a combination of Philips Pinnacle scripting tool and Java language pre-installed on each Pinnacle Sun Solaris workstation. A single Pinnacle script provide user a convenient access to the program when needed. The activated script will first exportmore » DVH data for user selected ROIs from current Pinnacle plan trial; a Java program then provides a simple GUI interface, utilizes the data to compute any user requested DVH quantities, compare with preset institutional DVH planning goals; if accepted by users, the program will also generate a PDF report of the results and export it from Pinnacle to EMR import folder via FTP. Results: The program was tested thoroughly and has been released for clinical use at our institution (Pinnacle Enterprise server with both thin clients and P3PC access), for all dosimetry and physics staff, with excellent feedback. It used to take a few minutes to use MS-Excel worksheet to calculate these DVH quantities for IMRT/VMAT plans, and manually save them as PDF report; with the new program, it literally takes a few mouse clicks in less than 30 seconds to complete the same tasks. Conclusion: A Pinnacle scripting and Java language based program is successfully implemented, customized to our institutional needs. It is shown to dramatically reduce time and effort needed for DVH quantities computing and EMR reporting.« less

  9. The development of remote wireless radiation dose monitoring system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Jin-woo; Chonbuk National University, Jeonjoo-Si; Jeong, Kyu-hwan

    Internet of things (IoT) technology has recently shown a large flow of IT trends in human life. In particular, our lives are now becoming integrated with a lot of items around the 'smart-phone' with IoT, including Bluetooth, Near Field Communication (NFC), Beacons, WiFi, and Global Positioning System (GPS). Our project focuses on the interconnection of radiation dosimetry and IoT technology. The radiation workers at a nuclear facility should hold personal dosimeters such as a Thermo-Luminescence Dosimeter (TLD), an Optically Stimulated Luminescence Dosimeter (OSL), pocket ionization chamber dosimeters, an Electronic Personal Dosimeter (EPD), or an alarm dosimeter on their body. Somemore » of them have functions that generate audible or visible alarms to radiation workers in a real working area. However, such devices used in radiation fields these days have no functions for communicating with other areas or the responsible personnel in real time. In particular, when conducting a particular task in a high dose area, or a number of repair works within a radiation field, radiation dose monitoring is important for the health of the workers and the work efficiency. Our project aims at the development of a remote wireless radiation dose monitoring system (RWRD) that can be used to monitor the radiation dose in a nuclear facility for radiation workers and a radiation protection program In this project, a radiation dosimeter is the detection device for personal radiation dose, a smart phone is the mobile wireless communication tool, and, Beacon is the wireless starter for the detection, communication, and position of the worker using BLE (Bluetooth Low Energy). In this report, we report the design of the RWRD and a demonstration case in a real radiation field. (authors)« less

  10. Treatment of Amblyopia Using Personalized Dosing Strategies: Statistical Modelling and Clinical Implementation.

    PubMed

    Wallace, Michael P; Stewart, Catherine E; Moseley, Merrick J; Stephens, David A; Fielder, Alistair R

    2016-12-01

    To generate a statistical model for personalizing a patient's occlusion therapy regimen. Statistical modelling was undertaken on a combined data set of the Monitored Occlusion Treatment of Amblyopia Study (MOTAS) and the Randomized Occlusion Treatment of Amblyopia Study (ROTAS). This exercise permits the calculation of future patients' total effective dose (TED)-that predicted to achieve their best attainable visual acuity. Daily patching regimens (hours/day) can be calculated from the TED. Occlusion data for 149 study participants with amblyopia (anisometropic in 50, strabismic in 43, and mixed in 56) were analyzed. Median time to best observed visual acuity was 63 days (25% and 75% quartiles; 28 and 91 days). Median visual acuity in the amblyopic eye at start of occlusion was 0.40 logMAR (quartiles 0.22 and 0.68 logMAR) and at end of occlusion was 0.12 (quartiles 0.025 and 0.32 logMAR). Median lower and upper estimates of TED were 120 hours (quartiles 34 and 242 hours), and 176 hours (quartiles 84 and 316 hours). The data suggest a piecewise linear relationship (P = 0.008) between patching dose-rate (hours/day) and TED with a single breakpoint estimated at 2.16 (standard error 0.51) hours/day, suggesting doses below 2.16 hours/day are less effective. We introduce the concept of TED of occlusion. Predictors for TED are visual acuity deficit, amblyopia type, and age at start of occlusion therapy. Dose-rates prescribed within the model range from 2.5 to 12 hours/day and can be revised dynamically throughout treatment in response to recorded patient compliance: a personalized dosing strategy.

  11. Occupational Radiation Exposure During Endovascular Aortic Repair

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sailer, Anna M., E-mail: anni.sailer@mumc.nl; Schurink, Geert Willem H., E-mail: gwh.schurink@mumc.nl; Bol, Martine E., E-mail: m.bol@maastrichtuniversity.nl

    PurposeThe aim of the study was to evaluate the radiation exposure to operating room personnel and to assess determinants for high personal doses during endovascular aortic repair.Materials and MethodsOccupational radiation exposure was prospectively evaluated during 22 infra-renal aortic repair procedures (EVAR), 11 thoracic aortic repair procedures (TEVAR), and 11 fenestrated or branched aortic repair procedures (FEVAR). Real-time over-lead dosimeters attached to the left breast pocket measured personal doses for the first operators (FO) and second operators (SO), radiology technicians (RT), scrub nurses (SN), anesthesiologists (AN), and non-sterile nurses (NSN). Besides protective apron and thyroid collar, no additional radiation shielding wasmore » used. Procedural dose area product (DAP), iodinated contrast volume, fluoroscopy time, patient’s body weight, and C-arm angulation were documented.ResultsAverage procedural FO dose was significantly higher during FEVAR (0.34 ± 0.28 mSv) compared to EVAR (0.11 ± 0.21 mSv) and TEVAR (0.06 ± 0.05 mSv; p = 0.003). Average personnel doses were 0.17 ± 0.21 mSv (FO), 0.042 ± 0.045 mSv (SO), 0.019 ± 0.042 mSv (RT), 0.017 ± 0.031 mSv (SN), 0.006 ± 0.007 mSv (AN), and 0.004 ± 0.009 mSv (NSN). SO and AN doses were strongly correlated with FO dose (p = 0.003 and p < 0.001). There was a significant correlation between FO dose and procedural DAP (R = 0.69, p < 0.001), iodinated contrast volume (R = 0.67, p < 0.001) and left-anterior C-arm projections >60° (p = 0.02), and a weak correlation with fluoroscopy time (R = 0.40, p = 0.049).ConclusionAverage FO dose was a factor four higher than SO dose. Predictors for high personal doses are procedural DAP, iodinated contrast volume, and left-anterior C-arm projections greater than 60°.« less

  12. Planning Guidance for Response to a Nuclear Detonation

    DTIC Science & Technology

    2009-01-16

    Radiation and Fallout One of the primary outputs from a nuclear explosion is radiation . Intense radiation is...dose rates based on the quantity of visible fallout. Therefore, visible fallout may possibly be used as an indicator of a direct radiation hazard...to survivors and response workers.15 The National Council on Radiation Protection and Measurements (NCRP) has recommended 10 R/hour (R/hour) as a

  13. Radiation transport codes for potential applications related to radiobiology and radiotherapy using protons, neutrons, and negatively charged pions

    NASA Technical Reports Server (NTRS)

    Armstrong, T. W.

    1972-01-01

    Several Monte Carlo radiation transport computer codes are used to predict quantities of interest in the fields of radiotherapy and radiobiology. The calculational methods are described and comparisions of calculated and experimental results are presented for dose distributions produced by protons, neutrons, and negatively charged pions. Comparisons of calculated and experimental cell survival probabilities are also presented.

  14. Baseline quantity of 131I, 137Cs, 134Cs and 40K in urinary excretions from Thai people and internal exposure dose

    NASA Astrophysics Data System (ADS)

    Peekhunthod, D.; Bangvirunrak, J.; Sansakon, S.; Nukultham, A.; Pukkhaw, T.

    2017-06-01

    Today, sealed and unsealed radioactive materials have been used in Thailand for various purposes such as medical, agricultural and industrial applications. There is a growing trend in the use of radioactive materials. Moreover, neighboring countries are planning to construct and operate nuclear power plants. In case of nuclear power plant accidents, radioactive releases in environment and intakes into human body by inhalation and ingestion causing long term health effects. This research aims to determine the radiation baseline quantity of interested relevant radionuclides such as 131I, 137Cs, 134Cs as well as a natural radionuclide, 40K in urine samples of Thai people by gamma spectrometry. Two types of detectors (NaI and HpGe detectors) are calibrated by mixed radionuclide standards of 109Cd, 57Co, 133Ba, 54Mn, 137Cs and 60Co, (energy range from 88 to 1,331 keV). 720 urine samples are collected over a 24 hour period from Thai volunteers with the age older than 18 years old, who lived in eight locations of Thailand. To reduce the effect of geometric difference, 30 ml of urine samples are prepared for counting measurement and efficiency determination. The radiation baseline quantity of 131I, 137Cs, 134Cs and 40K in 30 ml of urine samples are 0.37±0.09, 0.63±0.13, 0.39±0.08 and 7.84±1.63 Bq, respectively. Based on the assumption of intake (50% of the intake by ingestion and 50% of the intake by inhalation), internal dose for members of public are assessed. The committed dose equivalent due to an intake of 131I, 137Cs, 134Cs and 40K are 2.36E-03±1.66-03, 1.15E-01±8.61E-02, 1.16E-01±7.77E-02, 9.44E-01±3.56E-01 mSv per year, respectively.

  15. Dosing of selective serotonin reuptake inhibitors in children and adults before and after the FDA black-box warning

    PubMed Central

    Bushnell, Greta A; Stürmer, Til; Swanson, Sonja A; White, Alice; Azrael, Deborah; Pate, Virginia; Miller, Matthew

    2016-01-01

    Objective Prior research evaluated various effects of the antidepressant black-box warning on the risk of suicidality in children, but the dosing of antidepressants has not been considered. This study estimated, relative to the FDA warnings, whether the initial antidepressant dose prescribed decreased and the proportion augmenting dose on the second fill increased. Method The study utilized the LifeLink Health Plan Claims Database. The study cohort consisted of commercially insured children (5–17 years), young adults (18–24 years), and adults (25–64 years) initiating an SSRI (citalopram, fluoxetine, paroxetine, or sertraline) from 1/1/2000 to 12/31/2009. Dose-per-day was determined by days supply, strength, and quantity dispensed. Initiation on low dose, defined based on guidelines, and dose augmentations (dose increase >1mg/day) on the second prescription were considered across time periods related to the antidepressant warnings. Results Of 51,948 children who initiated an SSRI, 15% initiated on low dose in the period before the 2004 black-box warning and 31% in the period after the warning (a 16 percentage-point change); there was a smaller percentage-point change in young adults (6%) and adults (3%). The overall increase in dose augmentations in children and young adults was driven by the increase in patients initiating on a low dose. Conclusions As guidelines recommend children initiate antidepressant treatment on low dose, findings that an increased proportion of commercially insured children initiated an SSRI on low dose after the 2004 black-box warning suggest prescribing practices surrounding SSRI dosing improved in children following the warning but dosing practices still fall short of guidelines. PMID:26567938

  16. Measurement of Individual Doses of Radiation by Personal Dosimeter Is Important for the Return of Residents from Evacuation Order Areas after Nuclear Disaster

    PubMed Central

    Orita, Makiko; Hayashida, Naomi; Taira, Yasuyuki; Fukushima, Yoshiko; Ide, Juichi; Endo, Yuuko; Kudo, Takashi; Yamashita, Shunichi; Takamura, Noboru

    2015-01-01

    To confirm the availability of individual dose evaluation for the return of residents after the accident at the Fukushima Dai-ichi Nuclear Power Plant (FNPP), we evaluated individual doses of radiation as measured by personal dosimeters in residents who temporarily stayed in Evacuation Order Areas in Kawauchi village, which is partially located within a 20 km radius of the FNPP. We also compared individual doses with the external radiation doses estimated from the ambient dose rates and with doses estimated from the concentrations of radionuclides in the soil around each individual’s house. Individual doses were significantly correlated with the ambient doses in front of the entrances to the houses (r = 0.90, p<0.01), in the backyards (r = 0.41, p<0.01) and in the nearby fields (r = 0.80, p<0.01). The maximum cumulative ambient doses in the backyards and fields around the houses were 6.38 and 9.27 mSv/y, respectively. The maximum cumulative individual dose was 3.28 mSv/y, and the median and minimum doses were 1.35 and 0.71 mSv/y. The estimated external effective doses from concentrations of artificial radionuclides in soil samples ranged from 0.03 to 23.42 mSv/y. The individual doses were moderately correlated with external effective doses in the backyards (r = 0.38, p<0.01) and in the fields (r = 0.36, p<0.01); however, the individual doses were not significantly correlated with the external effective doses in front of the entrances (r = 0.01, p = 0.92). Our study confirmed that individual doses are low levels even in the evacuation order area in Kawauchi village, and external effective dose levels are certainly decreasing due to the decay of artificial radionuclides and the decontamination of contaminated soil. Long-term follow-up of individual doses as well as internal-exposure doses, environmental monitoring and reconstruction of infrastructure are needed so that residents may return to their hometowns after a nuclear disaster. PMID:25806523

  17. Measurement of individual doses of radiation by personal dosimeter is important for the return of residents from evacuation order areas after nuclear disaster.

    PubMed

    Orita, Makiko; Hayashida, Naomi; Taira, Yasuyuki; Fukushima, Yoshiko; Ide, Juichi; Endo, Yuuko; Kudo, Takashi; Yamashita, Shunichi; Takamura, Noboru

    2015-01-01

    To confirm the availability of individual dose evaluation for the return of residents after the accident at the Fukushima Dai-ichi Nuclear Power Plant (FNPP), we evaluated individual doses of radiation as measured by personal dosimeters in residents who temporarily stayed in Evacuation Order Areas in Kawauchi village, which is partially located within a 20 km radius of the FNPP. We also compared individual doses with the external radiation doses estimated from the ambient dose rates and with doses estimated from the concentrations of radionuclides in the soil around each individual's house. Individual doses were significantly correlated with the ambient doses in front of the entrances to the houses (r = 0.90, p<0.01), in the backyards (r = 0.41, p<0.01) and in the nearby fields (r = 0.80, p<0.01). The maximum cumulative ambient doses in the backyards and fields around the houses were 6.38 and 9.27 mSv/y, respectively. The maximum cumulative individual dose was 3.28 mSv/y, and the median and minimum doses were 1.35 and 0.71 mSv/y. The estimated external effective doses from concentrations of artificial radionuclides in soil samples ranged from 0.03 to 23.42 mSv/y. The individual doses were moderately correlated with external effective doses in the backyards (r = 0.38, p<0.01) and in the fields (r = 0.36, p<0.01); however, the individual doses were not significantly correlated with the external effective doses in front of the entrances (r = 0.01, p = 0.92). Our study confirmed that individual doses are low levels even in the evacuation order area in Kawauchi village, and external effective dose levels are certainly decreasing due to the decay of artificial radionuclides and the decontamination of contaminated soil. Long-term follow-up of individual doses as well as internal-exposure doses, environmental monitoring and reconstruction of infrastructure are needed so that residents may return to their hometowns after a nuclear disaster.

  18. Permethrin treated clothing to protect outdoor workers: evaluation of different methods for mosquito exposure against populations with differing resistance status.

    PubMed

    Richards, Stephanie L; Agada, Nwanne; Balanay, Jo Anne G; White, Avian V

    2018-02-01

    Minimizing arthropod exposure (e.g. mosquito and tick bites) is vital to protect health of outdoor workers. Personal protective measures can help protect against exposure. Here, the quantity of permethrin was evaluated for different fabric types after washing. Cone and petri dish exposure assays were used to investigate the knockdown/mortality of permethrin-susceptible and permethrin-resistant populations of mosquitoes. Permethrin-treated clothing was effective against the tested mosquito population that was susceptible to permethrin but not a permethrin-resistant population. Permethrin quantity was significantly highest in the 100% cotton fabric and for the 0 wash group. Permethrin quantity in fabrics decreased with washing. No significant differences (p > 0.05) were observed in knockdown/mortality rates for either exposure method. The protective effect of permethrin-treated clothing against mosquitoes is impacted by many factors, e.g. wash frequency, fabric type, and the susceptibility/resistance status of local mosquito populations.

  19. Evaluation of Effective Sources in Uncertainty Measurements of Personal Dosimetry by a Harshaw TLD System

    PubMed Central

    Hosseini Pooya, SM; Orouji, T

    2014-01-01

    Background: The accurate results of the individual doses in personal dosimety which are reported by the service providers in personal dosimetry are very important. There are national / international criteria for acceptable dosimetry system performance. Objective: In this research, the sources of uncertainties are identified, measured and calculated in a personal dosimetry system by TLD. Method: These sources are included; inhomogeneity of TLDs sensitivity, variability of TLD readings due to limited sensitivity and background, energy dependence, directional dependence, non-linearity of the response, fading, dependent on ambient temperature / humidity and calibration errors, which may affect on the dose responses. Some parameters which influence on the above sources of uncertainty are studied for Harshaw TLD-100 cards dosimeters as well as the hot gas Harshaw 6600 TLD reader system. Results: The individual uncertainties of each sources was measured less than 6.7% in 68% confidence level. The total uncertainty was calculated 17.5% with 95% confidence level. Conclusion: The TLD-100 personal dosimeters as well as the Harshaw TLD-100 reader 6600 system show the total uncertainty value which is less than that of admissible value of 42% for personal dosimetry services. PMID:25505769

  20. Ergosterol, arabitol and manitol as tracers for biological aerosols

    NASA Astrophysics Data System (ADS)

    Rudich, Y.; Burshtein, N.; Lang-Yona, N.

    2010-12-01

    Airborne fungi can cause a wide array of adverse responses in humans depending on the type and quantity present. Since dose and human response is highly individual, the sensitivity of a person exposed is also an important consideration. The abundance of bioaerosols in the ambient air and their health impacts depend on the season and on the environmental conditions. In order to quantify and identify fungi bioaerosols’ contribution to atmospheric aerosols and the impact to public health, it has been suggested to use chemicals that are typical of bioaerosols as biomarkers in chemical analysis of collected aerosols. An often used biomarker for determining the fungal biomass is ergosterol. Recently, Bauer et al. (2008) found that mannitol and arabitol concentrations are correlated with the fungal spore counts in atmospheric PM10. In this study, ergosterol, arabitol and mannitol were quantified in ambient aerosols collected in the Eastern Mediterranean region for 12 months in order to understand their annual and seasonal behavior and to test whether arabitol and mannitol are good predictors of fungi. Finally, correlations between ergosterol abundances with inorganic ions, humidity, temperature, and synoptic data in order to identify dominant sources of fungal spores were also studied. We will report on the measurements and the observed correlations between the different tracers.

  1. A Multi-institution, Retrospective Analysis of Cervix Intracavitary Brachytherapy Treatments. Part 1: Is EQD2 Good Enough for Reporting Radiobiological Effects?

    PubMed

    Fields, Emma C; Melvani, Rakhi; Hajdok, George; D'Souza, David; Jones, Bernard; Stuhr, Kelly; Diot, Quentin; Fisher, Christine M; Mukhopadhyay, Nitai; Todor, Dorin

    2017-09-01

    When brachytherapy doses are reported or added, biologically effective dose (BED) minimum dose covering 90% of the volume (D90) is used as if dose is delivered uniformly to the target. Unlike BED(D90), equivalent uniform BED (EUBED) and generalized biologically equivalent uniform dose (gBEUD) are quantities that integrate dose inhomogeneity. Here we compared BED(D90) and equivalent uniform BED (EUBED)/gBEUD in 3 settings: (1) 2 sites using tandem and ovoid (T&O) but different styles of implants; (2) 2 sites using different devices-T&O and tandem and ring (T&R)-and different styles; and (3) the same site using T&O and T&R with the same style. EUBED and gBEUD were calculated for 260 fractions from 3 institutions using BED(α/β = 10 Gy). EUBED uses an extra parameter α with smaller values associated with radioresistant tumors. Similarly, gBEUD uses a, which places variable emphasis on hot/cold spots. Distributions were compared using the Kolmogorov-Smirnoff test at 5% significance. For the 2 sites using T&O, the distribution of EUBED-BED(D90) was not different for values of α = 0.5 to 0.3 Gy -1 but was statistically different for values of α = 0.15 to 0.05 Gy -1 (P=.01, .002). The mean percentage differences between EUBED and BED(D90) ranged from 20% to 100% for α = 0.5 Gy -1 to 0.05 Gy -1 . Using gBEUD-BED(D90), the P values indicate the distributions to be similar for a = -10 but to be significantly different for other values of a (-5, -1, 1). Between sites and at the same site using T&O versus T&R, the distributions were statistically different with EUBED/gBEUD irrespective of parameter values at which these quantities were computed. These differences indicate that EUBED/gBEUD capture differences between the techniques and applicators that are not detected by the BED(D90). BED(D90) is unable to distinguish between plans created by different devices or optimized differently. EUBED/gBEUD distinguish between dose distributions created by different devices and styles of implant and planning. This discrepancy is particularly important with the increased use of magnetic resonance imaging and hybrid devices, whereby one has the ability to create dose distributions that are significant departures from the classic pear. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Body Weight Estimation for Dose-Finding and Health Monitoring of Lying, Standing and Walking Patients Based on RGB-D Data

    PubMed Central

    May, Stefan

    2018-01-01

    This paper describes the estimation of the body weight of a person in front of an RGB-D camera. A survey of different methods for body weight estimation based on depth sensors is given. First, an estimation of people standing in front of a camera is presented. Second, an approach based on a stream of depth images is used to obtain the body weight of a person walking towards a sensor. The algorithm first extracts features from a point cloud and forwards them to an artificial neural network (ANN) to obtain an estimation of body weight. Besides the algorithm for the estimation, this paper further presents an open-access dataset based on measurements from a trauma room in a hospital as well as data from visitors of a public event. In total, the dataset contains 439 measurements. The article illustrates the efficiency of the approach with experiments with persons lying down in a hospital, standing persons, and walking persons. Applicable scenarios for the presented algorithm are body weight-related dosing of emergency patients. PMID:29695098

  3. Body Weight Estimation for Dose-Finding and Health Monitoring of Lying, Standing and Walking Patients Based on RGB-D Data.

    PubMed

    Pfitzner, Christian; May, Stefan; Nüchter, Andreas

    2018-04-24

    This paper describes the estimation of the body weight of a person in front of an RGB-D camera. A survey of different methods for body weight estimation based on depth sensors is given. First, an estimation of people standing in front of a camera is presented. Second, an approach based on a stream of depth images is used to obtain the body weight of a person walking towards a sensor. The algorithm first extracts features from a point cloud and forwards them to an artificial neural network (ANN) to obtain an estimation of body weight. Besides the algorithm for the estimation, this paper further presents an open-access dataset based on measurements from a trauma room in a hospital as well as data from visitors of a public event. In total, the dataset contains 439 measurements. The article illustrates the efficiency of the approach with experiments with persons lying down in a hospital, standing persons, and walking persons. Applicable scenarios for the presented algorithm are body weight-related dosing of emergency patients.

  4. Osteoporosis in older persons: current pharmacotherapy and future directions.

    PubMed

    Duque, Gustavo

    2013-10-01

    Osteopororic fractures are highly prevalent in older persons having catastrophic consequences in their quality of life and increasing disability and mortality in this population. The mechanisms of osteoporosis in older persons are unique in terms of cellular changes and response to osteoporosis treatment. Therefore, specifically targeted treatments are required in this particular population. This paper provides an overview on the particular mechanisms of osteoporosis in older persons and the current and future therapeutic strategies to improve bone mass and prevent fractures in this population. Osteoporosis in older persons (especially in the old-old) has a unique pathophysiology that predisposes them to fractures thus having catastrophic consequences. Identification of patients at risk followed by therapies targeted to their cellular changes is pivotal to close the care gap observed in osteoporosis, predominantly in the older population. The treatment of osteoporosis has evolved from daily to yearly dosing thus facilitating compliance and effectiveness. It is expected that future biologically targeted treatments will have a similar separate dosing regime with better anti-fracture efficacy and lower incidence of side effects.

  5. 21 CFR 101.72 - Health claims: calcium, vitamin D, and osteoporosis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... bone mass, which has been identified as one of many risk factors in the development of osteoporosis. Peak bone mass is the total quantity of bone present at maturity, and experts believe that it has the greatest bearing on whether a person will be at risk of developing osteoporosis and related bone fractures...

  6. 21 CFR 101.72 - Health claims: calcium, vitamin D, and osteoporosis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... bone mass, which has been identified as one of many risk factors in the development of osteoporosis. Peak bone mass is the total quantity of bone present at maturity, and experts believe that it has the greatest bearing on whether a person will be at risk of developing osteoporosis and related bone fractures...

  7. 21 CFR 101.72 - Health claims: calcium, vitamin D, and osteoporosis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... bone mass, which has been identified as one of many risk factors in the development of osteoporosis. Peak bone mass is the total quantity of bone present at maturity, and experts believe that it has the greatest bearing on whether a person will be at risk of developing osteoporosis and related bone fractures...

  8. 21 CFR 101.72 - Health claims: calcium, vitamin D, and osteoporosis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... bone mass, which has been identified as one of many risk factors in the development of osteoporosis. Peak bone mass is the total quantity of bone present at maturity, and experts believe that it has the greatest bearing on whether a person will be at risk of developing osteoporosis and related bone fractures...

  9. 21 CFR 101.72 - Health claims: calcium, vitamin D, and osteoporosis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... bone mass, which has been identified as one of many risk factors in the development of osteoporosis. Peak bone mass is the total quantity of bone present at maturity, and experts believe that it has the greatest bearing on whether a person will be at risk of developing osteoporosis and related bone fractures...

  10. On Understanding the Notion of Limits and Infinitesimal Quantities

    ERIC Educational Resources Information Center

    Parameswaran, Revathy

    2007-01-01

    In this paper we explore the influence of students' personalized notion of "small" numbers based on real life experiences on their understanding of limits. Tests were conducted on two samples of students. The first sample, consisting of students in the XII grade, had been taught limits using an informal approach (i.e., without recourse to the…

  11. 10 CFR 32.53 - Luminous safety devices for use in aircraft: Requirements for license to manufacture, assemble...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... maximum quantity of tritium or promethium-147 in each device; (2) Details of construction and design; (3... information, including experimental studies and tests, required by the Commission to facilitate a... direct physical contact by any person with it; (3) The device is so designed that it cannot easily be...

  12. 10 CFR 32.53 - Luminous safety devices for use in aircraft: Requirements for license to manufacture, assemble...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... maximum quantity of tritium or promethium-147 in each device; (2) Details of construction and design; (3... information, including experimental studies and tests, required by the Commission to facilitate a... direct physical contact by any person with it; (3) The device is so designed that it cannot easily be...

  13. Quantity, Type, and Correlates of Physical Activity among American Middle Eastern University Students

    ERIC Educational Resources Information Center

    Kahan, David

    2009-01-01

    The prevalence of hypokinetic disease among persons of Middle Eastern heritage is higher than whites and research on American young adults of this population is limited. Therefore 214 tertiary students of Middle Eastern descent self-reported their physical activity (PA) over a 1-week monitoring period using pedometers and daily activity logs.…

  14. Magnetization transfer proportion: a simplified measure of dose response for polymer gel dosimetry.

    PubMed

    Whitney, Heather M; Gochberg, Daniel F; Gore, John C

    2008-12-21

    The response to radiation of polymer gel dosimeters has most often been described by measuring the nuclear magnetic resonance transverse relaxation rate as a function of dose. This approach is highly dependent upon the choice of experimental parameters, such as the echo spacing time for Carr-Purcell-Meiboom-Gill-type pulse sequences, and is difficult to optimize in imaging applications where a range of doses are applied to a single gel, as is typical for practical uses of polymer gel dosimetry. Moreover, errors in computing dose can arise when there are substantial variations in the radiofrequency (B1) field or resonant frequency, as may occur for large samples. Here we consider the advantages of using magnetization transfer imaging as an alternative approach and propose the use of a simplified quantity, the magnetization transfer proportion (MTP), to assess doses. This measure can be estimated through two simple acquisitions and is more robust in the presence of some sources of system imperfections. It also has a dependence upon experimental parameters that is independent of dose, allowing simultaneous optimization at all dose levels. The MTP is shown to be less susceptible to B1 errors than are CPMG measurements of R2. The dose response can be optimized through appropriate choices of the power and offset frequency of the pulses used in magnetization transfer imaging.

  15. Design, development, and initial operation of BabyScan: An in-vivo counter for children around Fukushima

    NASA Astrophysics Data System (ADS)

    Bronson, Frazier; Hayano, Ryugo; Oginni, Babatunde; Jaderstrom, Henrik; Ilie, Gabriela; Yamanaka, Shunji; Muramatsu, Isamu

    2015-06-01

    The Fukushima Dai-ichi accident has released large quantities of radionuclides, including 131I, 134Cs, and 137Cs. These radionuclides, when inhaled or ingested, cause internal dose to the individual. Whole Body Counting [WBC], also known as in-vivo counting is a common method to assess internal radioactivity as a tool to evaluate internal dose. The FastScan WBC system was widely used following the Chernobyl and the Fukushima accidents for in-vivo measurements of the population. Although the FastScan was designed for adults, it was successfully used for children by having them stand on a small stool. However small children and infants cannot stand, and have a much lower quantity of radioactive cesium. That required the development of a much more sensitive WBC system, called the BabyScan. A very important element of the project was to make the unit look esthetically pleasing, while not compromising performance. The steel shield was enclosed in a molded fiberglass exterior skin, whereas a carbon-fiber liner was used on the interior, to keep the background low. The system was calibrated using MCNP; on-site testing with phantoms confirmed the adequacy of the mathematical efficiency calibrations. The system has a Minimum Detectable Activity with a 4-min measurement of approximately 20 Bq for infants approximately 10 kg in weight, and 40 Bq for children approximately 30 kg in weight. The 40K that is naturally present is also reliably detected at the appropriate quantity for infants as small as 6 kg. Data from the first 365 subjects counted showed that 40K was detected in all of them, and that there was no 134Cs or 137Cs above the MDA levels.

  16. Bone morphogenetic protein-mediated interaction of periosteum and diaphysis. Citric acid and other factors influencing the generation of parosteal bone.

    PubMed

    Kübler, N; Urist, M R

    1990-09-01

    In rabbits, after long-bone growth is complete and the cambium layer regresses, mesenchymal-type cells with embryonic potential (competence) for bone development persist in the adventitial layer of periosteum. These cells are not determined osteoprogenitor cells (stem cells) because bone tissue differentiation does not occur when adult periosteum is transplanted into a heterotopic site. In this respect, adventitial cells differ from bone marrow stroma cells. In a parosteal orthotopic site in the space between the adult periosteum and diaphysis, implants of bone morphogenetic protein (BMP) and associated noncollagenous proteins (BMP/NCP) induce adventitia and adjacent muscle connective-tissue-derived cells to switch from a fibrogenetic to a chondroosteoprogenetic pattern of bone development. The quantity of induced bone is proportional to the dose of BMP/NCP in the range from 10 to 50 mg; immature rabbits produced larger deposits than mature rabbits in response to BMP/NCP. Preoperative local intramuscular injections of citric, edetic, or hyaluronic acids in specified concentrations markedly enhanced subperiosteal BMP/NCP-induced bone formation. The quantity of bovine or human BMP/NCP-induced bone formation in rabbits is also increased by very low-dose immunosuppression but not by bone mineral, tricalcium phosphate ceramic, inorganic calcium salts, or various space-occupying, unspecific chemical irritants. Although composities of BMP/NCP and allogeneic rabbit tendon collagen increased the quantity of bone in a parosteal site, in a heterotopic site the composite failed to induce bone formation. In a parosteal site, the conditions permitting BMP/NCP-induced bone formation develop, and the end product of the morphogenetic response is a duplicate diaphysis. How BMP reactivates the morphogenetic process in postfetal mesenchymal-type adventitial cells persisting in adult periosteum (including adjacent muscle attachments) is not known.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lindquist, N.; Hay, M.E.

    Marine larvae are consumed by a wide variety of generalist fishes and particle-feeding invertebrates, but larvae of any particular species probably constitute a small and variable portion of the diet for these consumers. Because virtually all consumers can ingest small quantities of noxious compounds with minimal detrimental effects, it is uncertain that toxic chemicals in larvae could be consumed in quantities sufficient to select for predator recognition and avoidance. Despite this, chemically defended larvae do occur. We show that, at low doses, secondary metabolites (the didemnins) from adults and larvae of the Caribbean tunicate Trididenmum solidum induced vomiting in fish,more » resulting in rapid learned aversion to the dedemnin-defended food. The particle-feeding anemone Aiptasia pallida did not learn to avoid the chemically defended food. When anemones ingested the chemical equivalent of 15 larvae/d, representing <2% of the mass of their total daily diet, the didemnins in the {open_quotes}larvae{close_quotes} significantly reduced: (1) growth of adults by 82%, (2) combined growth of adults and daughter clones by 76%, (3) production of daughter clones by 44%, and (4) average mass of individual daughter clones by 41%. At higher water temperatures, anemones cloned more rapidly. Significant differences in the number of daughter clones produced between treatment and control anemones occurred after only 4 d at seawater temperatures of 27{degrees}-29{degrees}C vs. 32 d at seawater temperatures of 18{degrees}-21{degrees}C. Consumption of even very small quantities of secondary metabolites can decrease consumer fitness substantially and select for predators that recognize and avoid chemically defended larvae, as do many consumers that co-occur with Trididemnum solidum larvae. This is the first rigorous demonstration that consumption of marine secondary metabolites can decrease consumer fitness when ingested at ecologically realistic doses. 59 refs., 5 figs., 3 tabs.« less

  18. Thyroid Cancer Following Childhood Low-Dose Radiation Exposure: A Pooled Analysis of Nine Cohorts.

    PubMed

    Lubin, Jay H; Adams, M Jacob; Shore, Roy; Holmberg, Erik; Schneider, Arthur B; Hawkins, Michael M; Robison, Leslie L; Inskip, Peter D; Lundell, Marie; Johansson, Robert; Kleinerman, Ruth A; de Vathaire, Florent; Damber, Lena; Sadetzki, Siegal; Tucker, Margaret; Sakata, Ritsu; Veiga, Lene H S

    2017-07-01

    The increased use of diagnostic and therapeutic procedures that involve radiation raises concerns about radiation effects, particularly in children and the radiosensitive thyroid gland. Evaluation of relative risk (RR) trends for thyroid radiation doses <0.2 gray (Gy); evidence of a threshold dose; and possible modifiers of the dose-response, e.g., sex, age at exposure, time since exposure. Pooled data from nine cohort studies of childhood external radiation exposure and thyroid cancer with individualized dose estimates, ≥1000 irradiated subjects or ≥10 thyroid cancer cases, with data limited to individuals receiving doses <0.2 Gy. Cohorts included the following: childhood cancer survivors (n = 2); children treated for benign diseases (n = 6); and children who survived the atomic bombings in Japan (n = 1). There were 252 cases and 2,588,559 person-years in irradiated individuals and 142 cases and 1,865,957 person-years in nonirradiated individuals. There were no interventions. Incident thyroid cancers. For both <0.2 and <0.1 Gy, RRs increased with thyroid dose (P < 0.01), without significant departure from linearity (P = 0.77 and P = 0.66, respectively). Estimates of threshold dose ranged from 0.0 to 0.03 Gy, with an upper 95% confidence bound of 0.04 Gy. The increasing dose-response trend persisted >45 years after exposure, was greater at younger age at exposure and younger attained age, and was similar by sex and number of treatments. Our analyses reaffirmed linearity of the dose response as the most plausible relationship for "as low as reasonably achievable" assessments for pediatric low-dose radiation-associated thyroid cancer risk. Copyright © 2017 Endocrine Society

  19. NOTE: Cell-phone interference with pocket dosimeters

    NASA Astrophysics Data System (ADS)

    Djajaputra, David; Nehru, Ramasamy; Bruch, Philip M.; Ayyangar, Komanduri M.; Raman, Natarajan V.; Enke, Charles A.

    2005-05-01

    Accurate reporting of personal dose is required by regulation for hospital personnel that work with radioactive material. Pocket dosimeters are commonly used for monitoring this personal dose. We show that operating a cell phone in the vicinity of a pocket dosimeter can introduce large and erroneous readings of the dosimeter. This note reports a systematic study of this electromagnetic interference. We found that simple practical measures are enough to mitigate this problem, such as increasing the distance between the cell phone and the dosimeter or shielding the dosimeter, while maintaining its sensitivity to ionizing radiation, by placing it inside a common anti-static bag.

  20. Cyclodextrins as excipients in tablet formulations.

    PubMed

    Conceição, Jaime; Adeoye, Oluwatomide; Cabral-Marques, Helena Maria; Lobo, José Manuel Sousa

    2018-04-22

    This paper aims to provide a critical review of cyclodextrins as excipients in tablet formulations, highlighting: (i) the principal pharmaceutical applications of cyclodextrins; (ii) the most relevant technological aspects in pharmaceutical formulation development; and (iii) the actual regulatory status of cyclodextrins. Moreover, several illustrative examples are presented. Cyclodextrins can be used as complexing excipients in tablet formulations for low-dose drugs. By contrast, for medium-dose drugs and/or when the complexation efficiency is low, the methods to enhance the complexation efficiency play a key part in reducing the cyclodextrin quantity. In addition, these compounds are used as fillers, disintegrants, binders and multifunctional direct compression excipients of the tablets. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Neutron H*(10) estimation and measurements around 18MV linac.

    PubMed

    Cerón Ramírez, Pablo Víctor; Díaz Góngora, José Antonio Irán; Paredes Gutiérrez, Lydia Concepción; Rivera Montalvo, Teodoro; Vega Carrillo, Héctor René

    2016-11-01

    Thermoluminescent dosimetry, analytical techniques and Monte Carlo calculations were used to estimate the dose of neutron radiation in a treatment room with a linear electron accelerator of 18MV. Measurements were carried out through neutron ambient dose monitors which include pairs of thermoluminescent dosimeters TLD 600 ( 6 LiF: Mg, Ti) and TLD 700 ( 7 LiF: Mg, Ti), which were placed inside a paraffin spheres. The measurements has allowed to use NCRP 151 equations, these expressions are useful to find relevant dosimetric quantities. In addition, photoneutrons produced by linac head were calculated through MCNPX code taking into account the geometry and composition of the linac head principal parts. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Measles Vaccination in the Presence or Absence of Maternal Measles Antibody: Impact on Child Survival

    PubMed Central

    Aaby, Peter; Martins, Cesário L.; Garly, May-Lill; Andersen, Andreas; Fisker, Ane B.; Claesson, Mogens H.; Ravn, Henrik; Rodrigues, Amabelia; Whittle, Hilton C.; Benn, Christine S.

    2014-01-01

    Background. Measles vaccine (MV) has a greater effect on child survival when administered in early infancy, when maternal antibody may still be present. Methods. To test whether MV has a greater effect on overall survival if given in the presence of maternal measles antibody, we reanalyzed data from 2 previously published randomized trials of a 2-dose schedule with MV given at 4–6 months and at 9 months of age. In both trials antibody levels had been measured before early measles vaccination. Results. In trial I (1993–1995), the mortality rate was 0.0 per 1000 person-years among children vaccinated with MV in the presence of maternal antibody and 32.3 per 1000 person-years without maternal antibody (mortality rate ratio [MRR], 0.0; 95% confidence interval [CI], 0–.52). In trial II (2003–2007), the mortality rate was 4.2 per 1000 person-years among children vaccinated in presence of maternal measles antibody and 14.5 per 1000 person-years without measles antibody (MRR, 0.29; 95% CI, .09–.91). Possible confounding factors did not explain the difference. In a combined analysis, children who had measles antibody detected when they received their first dose of MV at 4–6 months of age had lower mortality than children with no maternal antibody, the MRR being 0.22 (95% CI, .07–.64) between 4–6 months and 5 years. Conclusions. Child mortality in low-income countries may be reduced by vaccinating against measles in the presence of maternal antibody, using a 2-dose schedule with the first dose at 4–6 months (earlier than currently recommended) and a booster dose at 9–12 months of age. Clinical Trials Registration. NCT00168558. PMID:24829213

  3. Dosimetric verification of IMRT treatment planning using Monte Carlo simulations for prostate cancer

    NASA Astrophysics Data System (ADS)

    Yang, J.; Li, J.; Chen, L.; Price, R.; McNeeley, S.; Qin, L.; Wang, L.; Xiong, W.; Ma, C.-M.

    2005-03-01

    The purpose of this work is to investigate the accuracy of dose calculation of a commercial treatment planning system (Corvus, Normos Corp., Sewickley, PA). In this study, 30 prostate intensity-modulated radiotherapy (IMRT) treatment plans from the commercial treatment planning system were recalculated using the Monte Carlo method. Dose-volume histograms and isodose distributions were compared. Other quantities such as minimum dose to the target (Dmin), the dose received by 98% of the target volume (D98), dose at the isocentre (Diso), mean target dose (Dmean) and the maximum critical structure dose (Dmax) were also evaluated based on our clinical criteria. For coplanar plans, the dose differences between Monte Carlo and the commercial treatment planning system with and without heterogeneity correction were not significant. The differences in the isocentre dose between the commercial treatment planning system and Monte Carlo simulations were less than 3% for all coplanar cases. The differences on D98 were less than 2% on average. The differences in the mean dose to the target between the commercial system and Monte Carlo results were within 3%. The differences in the maximum bladder dose were within 3% for most cases. The maximum dose differences for the rectum were less than 4% for all the cases. For non-coplanar plans, the difference in the minimum target dose between the treatment planning system and Monte Carlo calculations was up to 9% if the heterogeneity correction was not applied in Corvus. This was caused by the excessive attenuation of the non-coplanar beams by the femurs. When the heterogeneity correction was applied in Corvus, the differences were reduced significantly. These results suggest that heterogeneity correction should be used in dose calculation for prostate cancer with non-coplanar beam arrangements.

  4. Four-Dimensional Positron Emission Tomography: Implications for Dose Painting of High-Uptake Regions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aristophanous, Michalis, E-mail: maristophanous@lroc.harvard.edu; Yap, Jeffrey T.; Killoran, Joseph H.

    Purpose: To investigate the behavior of tumor subvolumes of high [18F]-fluorodeoxyglucose (FDG) uptake as seen on clinical four-dimensional (4D) FDG-positron emission tomography (PET) scans. Methods and Materials: Four-dimensional FDG-PET/computed tomography scans from 13 patients taken before radiotherapy were available. The analysis was focused on regions of high uptake that are potential dose-painting targets. A total of 17 lesions (primary tumors and lymph nodes) were analyzed. On each one of the five phases of the 4D scan a classification algorithm was applied to obtain the region of highest uptake and segment the tumor volume. We looked at the behavior of bothmore » the high-uptake subvolume, called 'Boost,' and the segmented tumor volume, called 'Target.' We measured several quantities that characterize the Target and Boost volumes and quantified correlations between them. Results: The behavior of the Target could not always predict the behavior of the Boost. The shape deformation of the Boost regions was on average 133% higher than that of the Target. The gross to internal target volume expansion was on average 27.4% for the Target and 64% for the Boost, a statistically significant difference (p < 0.05). Finally, the inhale-to-exhale phase (20%) had the highest shape deformation for the Boost regions. Conclusions: A complex relationship between the measured quantities for the Boost and Target volumes is revealed. The results suggest that in cases in which advanced therapy techniques such as dose painting are being used, a close examination of the 4D PET scan should be performed.« less

  5. The TROPOMI surface UV algorithm

    NASA Astrophysics Data System (ADS)

    Lindfors, Anders V.; Kujanpää, Jukka; Kalakoski, Niilo; Heikkilä, Anu; Lakkala, Kaisa; Mielonen, Tero; Sneep, Maarten; Krotkov, Nickolay A.; Arola, Antti; Tamminen, Johanna

    2018-02-01

    The TROPOspheric Monitoring Instrument (TROPOMI) is the only payload of the Sentinel-5 Precursor (S5P), which is a polar-orbiting satellite mission of the European Space Agency (ESA). TROPOMI is a nadir-viewing spectrometer measuring in the ultraviolet, visible, near-infrared, and the shortwave infrared that provides near-global daily coverage. Among other things, TROPOMI measurements will be used for calculating the UV radiation reaching the Earth's surface. Thus, the TROPOMI surface UV product will contribute to the monitoring of UV radiation by providing daily information on the prevailing UV conditions over the globe. The TROPOMI UV algorithm builds on the heritage of the Ozone Monitoring Instrument (OMI) and the Satellite Application Facility for Atmospheric Composition and UV Radiation (AC SAF) algorithms. This paper provides a description of the algorithm that will be used for estimating surface UV radiation from TROPOMI observations. The TROPOMI surface UV product includes the following UV quantities: the UV irradiance at 305, 310, 324, and 380 nm; the erythemally weighted UV; and the vitamin-D weighted UV. Each of these are available as (i) daily dose or daily accumulated irradiance, (ii) overpass dose rate or irradiance, and (iii) local noon dose rate or irradiance. In addition, all quantities are available corresponding to actual cloud conditions and as clear-sky values, which otherwise correspond to the same conditions but assume a cloud-free atmosphere. This yields 36 UV parameters altogether. The TROPOMI UV algorithm has been tested using input based on OMI and the Global Ozone Monitoring Experiment-2 (GOME-2) satellite measurements. These preliminary results indicate that the algorithm is functioning according to expectations.

  6. Precedents of perceived social support: personality and early life experiences.

    PubMed

    Kitamura, T; Kijima, N; Watanabe, K; Takezaki, Y; Tanaka, E

    1999-12-01

    In order to examine the effects of personality and early life experiences on perceived social support, a total of 97 young Japanese women were investigated. Current interpersonal relationships were measured by an interview modified from Henderson et al.'s Interview Schedule for Social Interaction (ISSI). Personality was measured by Cloninger et al.'s Temperament and Character Inventory. Early life experiences at home and outside of home were also identified in the interview. The number of sources of perceived support was correlated with self-directness, while satisfaction with perceived support was correlated with novelty seeking and with low harm avoidance. No early life experiences--early loss of a parent, perceived parenting, childhood abuse experiences, experiences of being bullied and/or other life events--showed significant correlations with the number or satisfaction of supportive people. The quantity and quality of perception of social support differ in their link to personality, and perceived social support may, to some extent, be explainable in terms of personality.

  7. COMPILATION OF CONVERSION COEFFICIENTS FOR THE DOSE TO THE LENS OF THE EYE

    PubMed Central

    2017-01-01

    Abstract A compilation of fluence-to-absorbed dose conversion coefficients for the dose to the lens of the eye is presented. The compilation consists of both previously published data and newly calculated values: photon data (5 keV–50 MeV for both kerma approximation and full electron transport), electron data (10 keV–50 MeV), and positron data (1 keV–50 MeV) – neutron data will be published separately. Values are given for angles of incidence from 0° up to 90° in steps of 15° and for rotational irradiation. The data presented can be downloaded from this article's website and they are ready for use by Report Committee (RC) 26. This committee has been set up by the International Commission on Radiation Units and Measurements (ICRU) and is working on a ‘proposal for a redefinition of the operational quantities for external radiation exposure’. PMID:27542816

  8. Parenteral cidofovir for cytomegalovirus retinitis in patients with AIDS: the HPMPC peripheral cytomegalovirus retinitis trial. A randomized, controlled trial. Studies of Ocular complications of AIDS Research Group in Collaboration with the AIDS Clinical Trials Group.

    PubMed

    1997-02-15

    Cytomegalovirus (CMV) retinitis is a common infection and a major cause of visual loss in patients with the acquired immunodeficiency syndrome (AIDS). To evaluate intravenous cidofovir as a treatment for CMV retinitis. Two-stage, multicenter, phase II/III, randomized, controlled clinical trial. Ophthalmology and AIDS services at tertiary care medical centers. 64 patients with AIDS and previously untreated, small, peripheral CMV retinitis lesions (that is, patients at low risk for loss of visual acuity). Patients were randomly assigned to one of three groups: the deferral group, in which treatment was deferred until retinitis progressed; the low-dose cidofovir group, which received cidofovir, 5 mg/kg of body weight once weekly for 2 weeks, then maintenance therapy with cidofovir, 3 mg/kg once every 2 weeks; or the high-dose cidofovir group, which received cidofovir, 5 mg/kg once weekly for 2 weeks, then maintenance therapy with cidofovir, 5 mg/kg once every 2 weeks. To minimize nephrotoxicity, cidofovir was administered with hydration and probenecid. Progression of retinitis, evaluated in a masked manner by a fundus photograph reading center; the amount of retinal area involved by CMV; the loss of visual acuity; and morbidity. Median time to progression was 64 days in the low-dose cidofovir group and 21 days in the deferral group (P = 0.052, log-rank test). The median time to progression was not reached in the high-dose cidofovir group but was 20 days in the deferral group (P = 0.009, log-rank test). Analysis of the rates of increase in the retinal area affected by CMV confirmed the data on time to progression. The three groups had similar rates of visual loss. Proteinuria of 2+ or more occurred at rates of 2.6 per person-year in the deferral group, 2.8 per person-year in the low-dose cidofovir group (P > 0.02), and 6.8 per person-year in the high-dose cidofovir group (P = 0.135). No patient developed 4+ proteinuria, but two cidofovir recipients developed persistent elevations of serum creatinine levels at more than 177 mumol/L (2.0 mg/dL). Reactions to probenecid occurred at a rate of 0.70 per person-year. Intravenous cidofovir, high- or low-dose, effectively slowed the progression of CMV retinitis. Concomitant probenecid and hydration therapy, intermittent dosing, and monitoring for proteinuria seemed to minimize but not eliminate the risk for nephrotoxicity.

  9. Military Participants at U.S. Atmospheric Nuclear Weapons Testing— Methodology for Estimating Dose and Uncertainty

    PubMed Central

    Till, John E.; Beck, Harold L.; Aanenson, Jill W.; Grogan, Helen A.; Mohler, H. Justin; Mohler, S. Shawn; Voillequé, Paul G.

    2014-01-01

    Methods were developed to calculate individual estimates of exposure and dose with associated uncertainties for a sub-cohort (1,857) of 115,329 military veterans who participated in at least one of seven series of atmospheric nuclear weapons tests or the TRINITY shot carried out by the United States. The tests were conducted at the Pacific Proving Grounds and the Nevada Test Site. Dose estimates to specific organs will be used in an epidemiological study to investigate leukemia and male breast cancer. Previous doses had been estimated for the purpose of compensation and were generally high-sided to favor the veteran's claim for compensation in accordance with public law. Recent efforts by the U.S. Department of Defense (DOD) to digitize the historical records supporting the veterans’ compensation assessments make it possible to calculate doses and associated uncertainties. Our approach builds upon available film badge dosimetry and other measurement data recorded at the time of the tests and incorporates detailed scenarios of exposure for each veteran based on personal, unit, and other available historical records. Film badge results were available for approximately 25% of the individuals, and these results assisted greatly in reconstructing doses to unbadged persons and in developing distributions of dose among military units. This article presents the methodology developed to estimate doses for selected cancer cases and a 1% random sample of the total cohort of veterans under study. PMID:24758578

  10. Dose-response effects in an outbreak of Salmonella enteritidis.

    PubMed Central

    Mintz, E. D.; Cartter, M. L.; Hadler, J. L.; Wassell, J. T.; Zingeser, J. A.; Tauxe, R. V.

    1994-01-01

    The effects of ingested Salmonella enteritidis (SE) dose on incubation period and on the severity and duration of illness were estimated in a cohort of 169 persons who developed gastroenteritis after eating hollandaise sauce made from grade-A shell eggs. The cohort was divided into three groups based on self-reported dose of sauce ingested. As dose increased, median incubation period decreased (37 h in the low exposure group v. 21 h in the medium exposure group v. 17.5 h in the high exposure group, P = 0.006) and greater proportions reported body aches (71 v. 85 v. 94%, P = 0.0009) and vomiting (21 v. 56 v. 57%, P = 0.002). Among 118 case-persons who completed a follow-up questionnaire, increased dose was associated with increases in median weight loss in kilograms (3.2 v. 4.5 v. 5.0, P = 0.0001), maximum daily number of stools (12.5 v. 15.0 v. 20.0, P = 0.02), subjective rating of illness severity (P = 0.0007), and the number of days of confinement to bed (3.0 v. 6.5 v. 6.5, P = 0.04). In this outbreak, ingested dose was an important determinant of the incubation period, symptoms and severity of acute salmonellosis. PMID:8119352

  11. Dose-response effects in an outbreak of Salmonella enteritidis.

    PubMed

    Mintz, E D; Cartter, M L; Hadler, J L; Wassell, J T; Zingeser, J A; Tauxe, R V

    1994-02-01

    The effects of ingested Salmonella enteritidis (SE) dose on incubation period and on the severity and duration of illness were estimated in a cohort of 169 persons who developed gastroenteritis after eating hollandaise sauce made from grade-A shell eggs. The cohort was divided into three groups based on self-reported dose of sauce ingested. As dose increased, median incubation period decreased (37 h in the low exposure group v. 21 h in the medium exposure group v. 17.5 h in the high exposure group, P = 0.006) and greater proportions reported body aches (71 v. 85 v. 94%, P = 0.0009) and vomiting (21 v. 56 v. 57%, P = 0.002). Among 118 case-persons who completed a follow-up questionnaire, increased dose was associated with increases in median weight loss in kilograms (3.2 v. 4.5 v. 5.0, P = 0.0001), maximum daily number of stools (12.5 v. 15.0 v. 20.0, P = 0.02), subjective rating of illness severity (P = 0.0007), and the number of days of confinement to bed (3.0 v. 6.5 v. 6.5, P = 0.04). In this outbreak, ingested dose was an important determinant of the incubation period, symptoms and severity of acute salmonellosis.

  12. ADHERENCE TO ANTIRETROVIRAL THERAPY AMONG HIV-INFECTED ADULTS IN THE UNITED STATES

    PubMed Central

    Beer, Linda; Skarbinski, Jacek

    2015-01-01

    National estimates of antiretroviral therapy (ART) adherence and adherence support services utilization are needed to inform efforts to improve the health of HIV-infected persons in the United States. In a nationally representative sample of HIV-infected adults receiving medical care, 86% self-reported taking all ART doses in the past 72 hours. Overall, 20% reported using adherence support services and 2% reported an unmet need for services. If all nonadherent persons not receiving adherence support and all persons with a self-perceived unmet need for adherence support accessed services, resources to support ~42,673 additional persons would be needed. Factors associated with lower adherence included younger age, female gender, depression, stimulant use, binge alcohol use, greater than once-daily dosing, longer time since HIV diagnosis, and patient beliefs. Predictors of adherence are multifactorial so multiple targeted strategies to improve adherence are warranted. Providing adherence support services to all those in need may require additional resources. PMID:25490733

  13. Quantification and Evidence for Mechanically Metered Release of Pygidial Secretions in Formic Acid-Producing Carabid Beetles

    PubMed Central

    Will, Kipling W.; Gill, Aman S.; Lee, Hyeunjoo; Attygalle, Athula B.

    2010-01-01

    This study is the first to measure the quantity of pygidial gland secretions released defensively by carabid beetles (Coleoptera: Carabidae) and to accurately measure the relative quantity of formic acid contained in their pygidial gland reservoirs and spray emissions. Individuals of three typical formic acid producing species were induced to repeatedly spray, ultimately exhausting their chemical compound reserves. Beetles were subjected to faux attacks using forceps and weighed before and after each ejection of chemicals. Platynus brunneomarginatus (Mannerheim) (Platynini), P. ovipennis (Mannerheim) (Platynini) and Calathus ruficollis Dejean (Sphodrini), sprayed average quantities with standard error of 0.313 ± 0.172 mg, 0.337 ± 0.230 mg, and 0.197 ± 0.117 mg per spray event, respectively. The quantity an individual beetle released when induced to spray tended to decrease with each subsequent spray event. The quantity emitted in a single spray was correlated to the quantity held in the reservoirs at the time of spraying for beetles whose reserves are greater than the average amount emitted in a spray event. For beetles with a quantity less than the average amount sprayed in reserve there was no significant correlation. For beetles comparable in terms of size, physiological condition and gland reservoir fullness, the shape of the gland reservoirs and musculature determined that a similar effort at each spray event would mechanically meter out the release so that a greater amount was emitted when more was available in the reservoir. The average percentage of formic acid was established for these species as 34.2%, 73.5% and 34.1% for for P. brunneomarginatus, P. ovipennis and C. ruficollis, respectively. The average quantities of formic acid released by individuals of these species was less than two-thirds the amount shown to be lethal to ants in previously published experiments. However, the total quantity from multiple spray events from a single individual could aggregate to quantities at or above the lethal level, and lesser quantities are known to act as ant alarm pheromones. Using a model, one directed spray of the formic acid and hydrocarbon mix could spread to an area of 5–8 cm diameter and persisted for 9–22 seconds at a threshold level known to induce alarm behaviors in ants. These results show that carabid defensive secretions may act as a potent and relatively prolonged defense against ants or similar predators even at a sub-lethal dose. PMID:20575743

  14. Thyroid remnant ablation with 1110MBq of 131I in outpatients: measurement of effective dose to household members and establishment of safety precautions.

    PubMed

    Yoshimura, M; Tsutsui, H; Ikeda, N; Koizumi, K

    2013-03-01

    The aim of this study was to establish and confirm the safety of administering 1110MBq of 131I to outpatients. Total radiation exposure from patients to household members was hypothesized from the measured dose rate at 1 m when the patient is released. Actually we also measured the effective dose to household members who assisted outpatients during the first 7 days after the administration of 131I by personal dosimeter. A list of radiation safety precautions is given to the patient and household members. Behavioral reports about the distances and times of close contact throughout the 7 days are requested of each household member. The effective dose measured using the personal dosimeter to all household members employing several safety precautions was confirmed to be lower than the hypothesized dose calculated using our formula. And the mean whole-body effective dose rate over the 7 days in household members was 0.05±0.08 (range, 0.05 to 0.43) mSv, which specify that radiation exposure to household members of the outpatients who have just received ablative radiation therapy must be below 5.0 mSv/event. Remnant thyroid ablation with 1110MBq for outpatients showed that the radiation doses to household members were within the recommended constraint dose according to several safety precautions. The method of returning home after remnant thyroid ablation is thought to be the most important factor that determines the effective dose to household members of outpatients.

  15. Personalized cumulative UV tracking on mobiles & wearables.

    PubMed

    Dey, S; Sahoo, S; Agrawal, H; Mondal, A; Bhowmik, T; Tiwari, V N

    2017-07-01

    Maintaining a balanced Ultra Violet (UV) exposure level is vital for a healthy living as the excess of UV dose can lead to critical diseases such as skin cancer while the absence can cause vitamin D deficiency which has recently been linked to onset of cardiac abnormalities. Here, we propose a personalized cumulative UV dose (CUVD) estimation system for smartwatch and smartphone devices having the following novelty factors; (a) sensor orientation invariant measurement of UV exposure using a bootstrap resampling technique, (b) estimation of UV exposure using only light intensity (lux) sensor (c) optimal UV exposure dose estimation. Our proposed method will eliminate the need for a dedicated UV sensor thus widen the user base of the proposed solution, render it unobtrusive by eliminating the critical requirement of orienting the device in a direction facing the sun. The system is implemented on android mobile platform and validated on 1200 minutes of lux and UV index (UVI) data collected across several days covering morning to evening time frames. The result shows very impressive final UVI estimation accuracy. We believe our proposed solution will enable the future wearable and smartphone users to obtain a seamless personalized UV exposure dose across a day paving a way for simple yet very useful recommendations such as right skin protective measure for reducing risk factors of long term UV exposure related diseases like skin cancer and, cardiac abnormality.

  16. Effects of systemic carbidopa on dopamine synthesis in rat hypothalamus and striatum

    NASA Technical Reports Server (NTRS)

    Kaakkola, S.; Tuomainen, P.; Wurtman, R. J.; Maennistoe, P. T.

    1991-01-01

    Significant concentrations of carbidopa (CD) were found in rat hypothalamus, striatum, and in striatal microdialysis efflux after intraperitoneal administration of the drug. Efflux levels peaked one hour after administration of 100 mg/kg at 0.37 microg/kg or about 2 percent of serum levels. Concurrent CD levels in hypothalamus and striatum were about 2.5 percent and 1.5 percent, respectively, of corresponding serum levels. Levels of dopamine and its principal metabolites in striatal efflux were unaffected. The removal of the brain blood by saline perfusion decreased the striatal and hypothalamic CD concentrations only by 33 percent and 16 percent, respectively. In other rats receiving both CD and levodopa (LD), brain L-dopa, dopamine, and 3,4-dihydroxyphenvlacetic acid (DOPAC) levels after one hour tended to be proportionate to LD dose. When the LD dose remained constant, increasing the CD dose dose-dependently enhanced L-dopa levels in the hypothalamus and striatum. However, dopamine levels did not increase but, in contrast, decreased dose-dependently (although significantly only in the hypothalamus). CD also caused dose-dependent decrease in striatal 3-O-methyldopa (3-OMD) and in striatal and hypothalamic homovanillic acid (HVA), when the LD dose was 50 mg/kg. We conclude that, at doses exceedimg 50 mg/kg, sufficient quantities of CD enter the brain to inhibit dopamine formation, especially in the hypothalamus. Moreover, high doses of LD/CD, both of which are themselves catechols, can inhibit the O-methylation of brain catecholamines formed from the LD.

  17. Effects of systemic carbidopa on dopamine synthesis in rat hypothalamus and striatum

    NASA Technical Reports Server (NTRS)

    Kaakkola, S.; Tuomainen, P.; Wurtman, R. J.; Mannisto, P. T.

    1992-01-01

    Significant concentrations of carbidopa (CD) were found in rat hypothalamus, striatum, and in striatal microdialysis efflux after intraperitoneal administration of the drug. Efflux levels peaked one hour after administration of 100 mg/kg at 0.37 micrograms/ml, or about 2% of serum levels. Concurrent CD levels in hypothalamus and striatum were about 2.5% and 1.5%, respectively, of corresponding serum levels. Levels of dopamine and its principal metabolites in striatal efflux were unaffected. The removal of the brain blood by saline perfusion decreased the striatal and hypothalamic CD concentrations only by 33% and 16%, respectively. In other rats receiving both CD and levodopa (LD), brain L-dopa, dopamine and 3,4-dihydroxyphenylacetic acid (DOPAC) levels after one hour tended to be proportionate to LD dose. When the LD dose remained constant, increasing the CD dose dose-dependently enhanced L-dopa levels in the hypothalamus and striatum. However dopamine levels did not increase but, in contrast, decreased dose-dependently (although significantly only in the hypothalamus). CD also caused dose-dependent decrease in striatal 3-O-methyldopa (3-OMD) and in striatal and hypothalamic homovanillic acid (HVA), when the LD dose was 50 mg/kg. We conclude that, at doses exceeding 50 mg/kg, sufficient quantities of CD enter the brain to inhibit dopamine formation, especially in the hypothalamus. Moreover, high doses of LD/CD, both of which are themselves catechols, can inhibit the O-methylation of brain catecholamines formed from the LD.

  18. Observation model and parameter partials for the JPL geodetic (GPS) modeling software 'GPSOMC'

    NASA Technical Reports Server (NTRS)

    Sovers, O. J.

    1990-01-01

    The physical models employed in GPSOMC, the modeling module of the GIPSY software system developed at JPL for analysis of geodetic Global Positioning Satellite (GPS) measurements are described. Details of the various contributions to range and phase observables are given, as well as the partial derivatives of the observed quantities with respect to model parameters. A glossary of parameters is provided to enable persons doing data analysis to identify quantities with their counterparts in the computer programs. The present version is the second revision of the original document which it supersedes. The modeling is expanded to provide the option of using Cartesian station coordinates; parameters for the time rates of change of universal time and polar motion are also introduced.

  19. Cosmic radiation dose measurements from the RaD-X flight campaign

    NASA Astrophysics Data System (ADS)

    Mertens, Christopher J.; Gronoff, Guillaume P.; Norman, Ryan B.; Hayes, Bryan M.; Lusby, Terry C.; Straume, Tore; Tobiska, W. Kent; Hands, Alex; Ryden, Keith; Benton, Eric; Wiley, Scott; Gersey, Brad; Wilkins, Richard; Xu, Xiaojing

    2016-10-01

    The NASA Radiation Dosimetry Experiment (RaD-X) stratospheric balloon flight mission obtained measurements for improving the understanding of cosmic radiation transport in the atmosphere and human exposure to this ionizing radiation field in the aircraft environment. The value of dosimetric measurements from the balloon platform is that they can be used to characterize cosmic ray primaries, the ultimate source of aviation radiation exposure. In addition, radiation detectors were flown to assess their potential application to long-term, continuous monitoring of the aircraft radiation environment. The RaD-X balloon was successfully launched from Fort Sumner, New Mexico (34.5°N, 104.2°W) on 25 September 2015. Over 18 h of flight data were obtained from each of the four different science instruments at altitudes above 20 km. The RaD-X balloon flight was supplemented by contemporaneous aircraft measurements. Flight-averaged dosimetric quantities are reported at seven altitudes to provide benchmark measurements for improving aviation radiation models. The altitude range of the flight data extends from commercial aircraft altitudes to above the Pfotzer maximum where the dosimetric quantities are influenced by cosmic ray primaries. The RaD-X balloon flight observed an absence of the Pfotzer maximum in the measurements of dose equivalent rate.

  20. Cosmic Radiation Dose Measurements from the RaD-X Flight Campaign

    NASA Technical Reports Server (NTRS)

    Mertens, Christopher J.; Gronoff, Guillaume P.; Norman, Ryan B.; Hayes, Bryan M.; Lusby, Terry C.; Straume, Tore; Tobiska, W. Kent; Hands, Alex; Ryden, Keith; Benton, Eric; hide

    2016-01-01

    The NASA Radiation Dosimetry Experiment (RaD-X) stratospheric balloon flight mission obtained measurements for improving the understanding of cosmic radiation transport in the atmosphere and human exposure to this ionizing radiation field in the aircraft environment. The value of dosimetric measurements from the balloon platform is that they can be used to characterize cosmic ray primaries, the ultimate source of aviation radiation exposure. In addition, radiation detectors were flown to assess their potential application to long-term, continuous monitoring of the aircraft radiation environment. The RaD-X balloon was successfully launched from Fort Sumner, New Mexico (34.5 degrees North, 104.2 degrees West) on 25 September 2015. Over 18 hours of flight data were obtained from each of the four different science instruments at altitudes above 20 kilometers. The RaD-X balloon flight was supplemented by contemporaneous aircraft measurements. Flight-averaged dosimetric quantities are reported at seven altitudes to provide benchmark measurements for improving aviation radiation models. The altitude range of the flight data extends from commercial aircraft altitudes to above the Pfotzer maximum where the dosimetric quantities are influenced by cosmic ray primaries. The RaD-X balloon flight observed an absence of the Pfotzer maximum in the measurements of dose equivalent rate.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    T. R. Saffle; R. G. Mitchell; R. B. Evans

    The results of the various monitoring programs for 1998 indicated that radioactivity from the DOE's Idaho National Engineering and Environmental Laboratory (INEEL) operations could generally not be distinguished from worldwide fallout and natural radioactivity in the region surrounding the INEEL. Although some radioactive materials were discharged during INEEL operations, concentrations in the offsite environment and doses to the surrounding population were far less than state of Idaho and federal health protection guidelines. Gross alpha and gross beta measurements, used as a screening technique for air filters, were investigated by making statistical comparisons between onsite or boundary location concentrations and themore » distant community group concentrations. Gross alpha activities were generally higher at distant locations than at boundary and onsite locations. Air samples were also analyzed for specific radionuclides. Some human-made radionuclides were detected at offsite locations, but most were near the minimum detectable concentration and their presence was attributable to natural sources, worldwide fallout, and statistical variations in the analytical results rather than to INEEL operations. Low concentrations of 137Cs were found in muscle tissue and liver of some game animals and sheep. These levels were mostly consistent with background concentrations measured in animals sampled onsite and offsite in recent years. Ionizing radiation measured simultaneously at the INEEL boundary and distant locations using environmental dosimeters were similar and showed only background levels. The maximum potential population dose from submersion, ingestion, inhalation, and deposition to the approximately 121,500 people residing within an 80-km (50-mi) radius from the geographical center of the INEEL was estimated to be 0.08 person-rem (8 x 10-4 person-Sv) using the MDIFF air dispersion model. This population dose is less than 0.0002 percent of the estimated 43,7 00 person-rem (437 person-Sv) population dose from background radioactivity.« less

  2. [Retrospective Cytogenetic Dose Evaluation. II. Computer Data Processing in Persons Irradiated in Different Radiation Accidents].

    PubMed

    Nugis, V Yu; Khvostunov, I K; Goloub, E V; Kozlova, M G; Nadejinal, N M; Galstian, I A

    2015-01-01

    The method for retrospective dose assessment based on the analysis of cell distribution by the number of dicentrics and unstable aberrations using a special computer program was earlier developed based on the data about the persons irradiated as a result of the accident at the Chernobyl nuclear power plant. This method was applied for the same purpose for data processing of repeated cytogenetic studies of the patients exposed to γ-, γ-β- or γ-neutron radiation in various situations. As a whole, this group was followed up in more distant periods (17-50 years) after exposure than Chernobyl patients (up to 25 years). The use for retrospective dose assessment of the multiple regression equations obtained for the Chernobyl cohort showed that the equation, which includes computer recovered estimate of the dose and the time elapsed after irradiation, was generally unsatisfactory (r = 0.069 at p = 0.599). Similar equations with recovered estimate of the dose and frequency of abnormal chromosomes in a distant period or with all three parameters as variables gave better results (r = 0.686 at p = 0.000000001 and r = 0.542 at p = 0.000008, respectively).

  3. 40 CFR 190.02 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... sup-port -of these operations, and the reuse of -recovered non-uranium special nu-clear and by-product...) Site means the area contained within the boundary of a location under the control of persons possessing... second. (One millicurie (mCi)=0.001 Ci.) (h) Dose equivalent means the product of absorbed dose and...

  4. 40 CFR 190.02 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... sup-port -of these operations, and the reuse of -recovered non-uranium special nu-clear and by-product...) Site means the area contained within the boundary of a location under the control of persons possessing... second. (One millicurie (mCi)=0.001 Ci.) (h) Dose equivalent means the product of absorbed dose and...

  5. 40 CFR 190.02 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... sup-port -of these operations, and the reuse of -recovered non-uranium special nu-clear and by-product...) Site means the area contained within the boundary of a location under the control of persons possessing... second. (One millicurie (mCi)=0.001 Ci.) (h) Dose equivalent means the product of absorbed dose and...

  6. Organ and effective dose rate coefficients for submersion exposure in occupational settings

    DOE PAGES

    Veinot, K. G.; Y-12 National Security Complex, Oak Ridge, TN; Dewji, S. A.; ...

    2017-08-24

    External dose coefficients for environmental exposure scenarios are often computed using assumption on infinite or semi-infinite radiation sources. For example, in the case of a person standing on contaminated ground, the source is assumed to be distributed at a given depth (or between various depths) and extending outwards to an essentially infinite distance. In the case of exposure to contaminated air, the person is modeled as standing within a cloud of infinite, or semi-infinite, source distribution. However, these scenarios do not mimic common workplace environments where scatter off walls and ceilings may significantly alter the energy spectrum and dose coefficients.more » In this study, dose rate coefficients were calculated using the International Commission on Radiological Protection (ICRP) reference voxel phantoms positioned in rooms of three sizes representing an office, laboratory, and warehouse. For each room size calculations using the reference phantoms were performed for photons, electrons, and positrons as the source particles to derive mono-energetic dose rate coefficients. Since the voxel phantoms lack the resolution to perform dose calculations at the sensitive depth for the skin, a mathematical phantom was developed and calculations were performed in each room size with the three source particle types. Coefficients for the noble gas radionuclides of ICRP Publication 107 (e.g., Ne, Ar, Kr, Xe, and Rn) were generated by folding the corresponding photon, electron, and positron emissions over the mono-energetic dose rate coefficients. Finally, results indicate that the smaller room sizes have a significant impact on the dose rate per unit air concentration compared to the semi-infinite cloud case. For example, for Kr-85 the warehouse dose rate coefficient is 7% higher than the office dose rate coefficient while it is 71% higher for Xe-133.« less

  7. Organ and effective dose rate coefficients for submersion exposure in occupational settings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veinot, K. G.; Y-12 National Security Complex, Oak Ridge, TN; Dewji, S. A.

    External dose coefficients for environmental exposure scenarios are often computed using assumption on infinite or semi-infinite radiation sources. For example, in the case of a person standing on contaminated ground, the source is assumed to be distributed at a given depth (or between various depths) and extending outwards to an essentially infinite distance. In the case of exposure to contaminated air, the person is modeled as standing within a cloud of infinite, or semi-infinite, source distribution. However, these scenarios do not mimic common workplace environments where scatter off walls and ceilings may significantly alter the energy spectrum and dose coefficients.more » In this study, dose rate coefficients were calculated using the International Commission on Radiological Protection (ICRP) reference voxel phantoms positioned in rooms of three sizes representing an office, laboratory, and warehouse. For each room size calculations using the reference phantoms were performed for photons, electrons, and positrons as the source particles to derive mono-energetic dose rate coefficients. Since the voxel phantoms lack the resolution to perform dose calculations at the sensitive depth for the skin, a mathematical phantom was developed and calculations were performed in each room size with the three source particle types. Coefficients for the noble gas radionuclides of ICRP Publication 107 (e.g., Ne, Ar, Kr, Xe, and Rn) were generated by folding the corresponding photon, electron, and positron emissions over the mono-energetic dose rate coefficients. Finally, results indicate that the smaller room sizes have a significant impact on the dose rate per unit air concentration compared to the semi-infinite cloud case. For example, for Kr-85 the warehouse dose rate coefficient is 7% higher than the office dose rate coefficient while it is 71% higher for Xe-133.« less

  8. Weekend personal ultraviolet radiation exposure in four cities in Australia: influence of temperature, humidity and ambient ultraviolet radiation.

    PubMed

    Xiang, Fan; Harrison, Simone; Nowak, Madeleine; Kimlin, Michael; Van der Mei, Ingrid; Neale, Rachel E; Sinclair, Craig; Lucas, Robyn M

    2015-02-01

    To examine the effects of meteorological factors on weekend sun exposure behaviours and personal received dose of ultraviolet radiation (UVR) in Australian adults. Australian adults (n=1002) living in Townsville (19°S, 146°E), Brisbane (27°S, 153°E), Canberra (35°S, 149°E) and Hobart (43°S, 147°E) were recruited between 2009 and 2010. Data on sun exposure behaviours were collected by daily sun exposure dairies; personal UVR exposure was measured with a polysulphone dosimeter. Meteorological data were obtained from the Australian Bureau of Meteorology; ambient UVR levels were estimated using the Ozone Monitoring Instrument data. Higher daily maximum temperatures were associated with reduced likelihood of wearing a long-sleeved shirt or wearing long trousers in Canberra and Hobart, and higher clothing-adjusted UVR dose in Canberra. Higher daily humidity was associated with less time spent outdoors in Canberra. Higher ambient UVR level was related to a greater clothing-adjusted personal UVR dose in Hobart and a greater likelihood of using sunscreen in Townsville. The current findings enhance our understanding of the impact of weather conditions on the population's sun exposure behaviours. This information will allow us to refine current predictive models for UVR-related diseases, and guide future health service and health promotion needs. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Impact of enterovirus and other enteric pathogens on oral polio and rotavirus vaccine performance in Bangladeshi infants.

    PubMed

    Taniuchi, Mami; Platts-Mills, James A; Begum, Sharmin; Uddin, Md Jashim; Sobuz, Shihab U; Liu, Jie; Kirkpatrick, Beth D; Colgate, E Ross; Carmolli, Marya P; Dickson, Dorothy M; Nayak, Uma; Haque, Rashidul; Petri, William A; Houpt, Eric R

    2016-06-08

    Oral polio vaccine (OPV) and rotavirus vaccine (RV) exhibit poorer performance in low-income settings compared to high-income settings. Prior studies have suggested an inhibitory effect of concurrent non-polio enterovirus (NPEV) infection, but the impact of other enteric infections has not been comprehensively evaluated. In urban Bangladesh, we tested stools for a broad range of enteric viruses, bacteria, parasites, and fungi by quantitative PCR from infants at weeks 6 and 10 of life, coincident with the first OPV and RV administration respectively, and examined the association between enteropathogen quantity and subsequent OPV serum neutralizing titers, serum rotavirus IgA, and rotavirus diarrhea. Campylobacter and enterovirus (EV) quantity at the time of administration of the first dose of OPV was associated with lower OPV1-2 serum neutralizing titers, while enterovirus quantity was also associated with diminished rotavirus IgA (-0.08 change in log titer per tenfold increase in quantity; P=0.037), failure to seroconvert (OR 0.78, 95% CI: 0.64-0.96; P=0.022), and breakthrough rotavirus diarrhea (OR 1.34, 95% CI: 1.05-1.71; P=0.020) after adjusting for potential confounders. These associations were not observed for Sabin strain poliovirus quantity. In this broad survey of enteropathogens and oral vaccine performance we find a particular association between EV carriage, particularly NPEV, and OPV immunogenicity and RV protection. Strategies to reduce EV infections may improve oral vaccine responses. ClinicalTrials.gov Identifier: NCT01375647. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. Metrics to assess the quantity of antibiotic use in the outpatient setting: a systematic review followed by an international multidisciplinary consensus procedure.

    PubMed

    Versporten, Ann; Gyssens, Inge C; Pulcini, Céline; Monnier, Annelie A; Schouten, Jeroen; Milanic, Romina; Stanic Benic, Mirjana; Tebano, Gianpiero; Le Maréchal, Marion; Zanichelli, Veronica; Huttner, Benedikt; Vlahovic-Palcevski, Vera; Goossens, Herman; Hulscher, Marlies E; Adriaenssens, Niels

    2018-06-01

    The international Innovative Medicines Initiative (IMI) project DRIVE-AB (Driving Reinvestment in Research and Development and Responsible Antibiotic Use) aims to develop a global definition of 'responsible' antibiotic use. To identify consensually validated quantity metrics for antibiotic use in the outpatient setting. First, outpatient quantity metrics (OQMs) were identified by a systematic search of literature and web sites published until 12 December 2014. Identified OQMs were evaluated by a multidisciplinary, international stakeholder panel using a RAND-modified Delphi procedure. Two online questionnaires and a face-to-face meeting between them were conducted to assess OQM relevance for measuring the quantity of antibiotic use on a nine-point Likert scale, to add comments or to propose new metrics. A total of 597 articles were screened, 177 studies met criteria for full-text screening and 138 were finally included. Twenty different OQMs were identified and appraised by 23 stakeholders. During the first survey, 14 OQMs were excluded and 6 qualified for discussion. During the face-to-face meeting, 10 stakeholders retained five OQMs and suggestions were made considering context and combination of metrics. The final set of metrics included defined daily doses, treatments/courses and prescriptions per defined population, treatments/courses and prescriptions per defined number of physician contacts and seasonal variation of total antibiotic use. A small set of consensually validated metrics to assess the quantity of antibiotic use in the outpatient setting was obtained, enabling (inter)national comparisons. The OQMs will help build a global conceptual framework for responsible antibiotic use.

  11. Effect of sleep-inducing music on sleep in persons with percutaneous transluminal coronary angiography in the cardiac care unit.

    PubMed

    Ryu, Min-Jung; Park, Jeong Sook; Park, Heeok

    2012-03-01

    The study compared the effect of earplug-delivered sleep-inducing music on sleep in persons with percutaneous transluminal coronary angiography in the cardiac care unit. Diverse types of music have been claimed to improve sleeping elsewhere, but relatively little is known in South Korea. Most studies investigating the effect of sleep-inducing music on sleep have involved persons with insomnia, even though many persons with cardiovascular disease in the intensive care unit suffer from sleeping problems. There is a need to investigate the effect of sleep-inducing music on sleep disorders in persons with percutaneous transluminal coronary angiography in the cardiac care unit. An experimental research design was used. Data collection was conducted in the cardiac care unit of K University Hospital in D city, from 3 September-4 October 2010. Fifty-eight subjects participated and were randomly assigned to the experimental group (earplug-delivered sleep-inducing music for 52 min beginning at 10:00 pm, while wearing an eyeshield, n = 29) and the control group (no music, but earplugs and eyeshield worn, n = 29). The quantity and quality of sleep were measured using questionnaires at 7 am the next morning for each group. Participants in the experimental group reported that the sleeping quantity and quality were significantly higher than control group (t = 3·181, p = 0·002, t = 5·269, p < 0·001, respectively). Sleep-inducing music significantly improved sleep in patients with percutaneous transluminal coronary angiography at a cardiac care unit. Offering earplugs and playing sleep-inducing music may be a meaningful and easily enacted nursing intervention to improve sleep for intensive care unit patients. Nurses working at cardiac care unit can use music to improve sleeping in clients with percutaneous transluminal coronary angiography. © 2011 Blackwell Publishing Ltd.

  12. BIOMAKERS OF EXPOSURE AND METABOLIC SUSCEPTIBILITY TO FINE PARTICLE AIR POLLUTION

    EPA Science Inventory

    The influence of metabolic susceptibility (GSTM1 and NAT2 genotypes) on the association between personal air exposures and biomarkers of exposure, dose, and genetic damage were measured for 60 individuals in two regions exposed to ambient air in the Czech Republic. Personal mon...

  13. The effects of hedonically acceptable red pepper doses on thermogenesis and appetite

    PubMed Central

    Ludy, Mary-Jon; Mattes, Richard D.

    2010-01-01

    Previous studies suggest consumption of red pepper (RP) promotes negative energy balance. However, the RP dose provided in these studies (up to 10 g/meal) usually exceeded the amount preferred by the general population in the United States (mean = ~ 1 g/meal). The objective of this study was to evaluate the effects of hedonically acceptable RP doses served at a single meal in healthy, lean individuals on thermogenesis and appetite. Twenty-five men and women (aged 23.0 ± 0.5 y, BMI 22.6 ± 0.3 kg/m2, 13 spicy food users and 12 non-users) participated in a randomized crossover trial during which they consumed a standardized quantity (1 g); their preferred quantity (regular spicy foods users 1.8 ± 0.3 g/meal, non-users 0.3 ± 0.1 g/meal); or no RP. Energy expenditure, core body and skin temperature, and appetite were measured. Postprandial energy expenditure and core body temperature were greater, and skin temperature was lower, after test loads with 1 g RP than no RP. Respiratory quotient was lower after the preferred RP dose was ingested orally, compared to in capsule form. These findings suggest that RP’s effects on energy balance stem from a combination of metabolic and sensory inputs, and that oral exposure is necessary to achieve RP’s maximum benefits. Energy intake was lower after test loads with 1 g RP than no RP in non-users, but not in users. Preoccupation with food, and the desire to consume fatty, salty, and sweet foods were decreased more (or tended to be decreased more) in non-users than users after a 1 g RP test load, but did not vary after a test load with no RP. This suggests that individuals may become desensitized to the effects of RP with long-term spicy food intake. PMID:21093467

  14. Performance of optically stimulated luminescence Al₂O₃ dosimeter for low doses of diagnostic energy X-rays.

    PubMed

    Lim, Chang Seon; Lee, Sang Bock; Jin, Gye Hwan

    2011-10-01

    Personal dosimeters measure the radiation dose from exposure to hazardous sources outside the body. The present manuscript evaluates the performance of a commercially available optically stimulated luminescence (OSL) Al₂O₃ dosimeter using diagnostic energy X-rays. The OSL system satisfies the ANSI N13.11-2001 performance criteria for low dose diagnostic energy X-rays. Non-uniformity of sensitivity, dose linearity, X-ray energy response, and angular performance are all within the criteria of IEC-62387-1(2007). Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. ESTIMATION OF EXPOSURE DOSES FOR THE SAFE MANAGEMENT OF NORM WASTE DISPOSAL.

    PubMed

    Jeong, Jongtae; Ko, Nak Yul; Cho, Dong-Keun; Baik, Min Hoon; Yoon, Ki-Hoon

    2018-03-16

    Naturally occurring radioactive materials (NORM) wastes with different radiological characteristics are generated in several industries. The appropriate options for NORM waste management including disposal options should be discussed and established based on the act and regulation guidelines. Several studies calculated the exposure dose and mass of NORM waste to be disposed in landfill site by considering the activity concentration level and exposure dose. In 2012, the Korean government promulgated an act on the safety control of NORM around living environments to protect human health and the environment. For the successful implementation of this act, we suggest a reference design for a landfill for the disposal of NORM waste. Based on this reference landfill, we estimate the maximum exposure doses and the relative impact of each pathway to exposure dose for three scenarios: a reference scenario, an ingestion pathway exclusion scenario, and a low leach rate scenario. Also, we estimate the possible quantity of NORM waste disposal into a landfill as a function of the activity concentration level of U series, Th series and 40K and two kinds of exposure dose levels, 1 and 0.3 mSv/y. The results of this study can be used to support the establishment of technical bases of the management strategy for the safe disposal of NORM waste.

  16. Comparative analysis of dosimetry parameters for nuclear medicine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Toohey, R.E.; Stabin, M.G.

    For years many have employed the concept of ``total-body dose`` or ``whole-body dose,`` i.e., the total energy deposited in the body divided by the mass of the body, when evaluating the risks of different nuclear medicine procedures. The effective dose equivalent (H{sub E}), first described in ICRP Publication 26, has been accepted by some as a better quantity to use in evaluating the total risk of a procedure, but its use has been criticized by others primarily because the tissue weighting factors were intended for use in the radiation worker, rather than the nuclear medicine patient population. Nevertheless, in ICRPmore » Publication 52, the ICRP has suggested that the H{sub E} may be used in nuclear medicine. The ICRP also has published a compendium of dose estimates, including H{sub E} values, for various nuclear medicine procedures at various ages in ICRP Publication 53. The effective dose (E) of ICRP Publication 60 is perhaps more suitable for use in nuclear medicine, with tissue weighting factors based on the entire population. Other comparisons of H{sub E} and E have been published. The authors have used the program MIRDOSE 3.1 to compute total-body dose, H{sub E}, and E for 62 radiopharmaceutical procedures, based on the best current biokinetic data available.« less

  17. The possible mechanism of silver nanoparticle impact on hippocampal synaptic plasticity and spatial cognition in rats.

    PubMed

    Liu, Ye; Guan, Wei; Ren, Guogang; Yang, Zhuo

    2012-03-25

    Silver nanoparticles (Ag-np) are very promising engineered nanomaterials which play an important role in the world biomedical, healthcare and in general nanotechnology applications. With the most impressive effect in antibacterial and many other broad-spectrum biotechnological advantages, Ag-np in real applications is still a controversial issue. This study investigated effects of the Ag-np on hippocampal synaptic plasticity and spatial cognition in rats and followed with the research on their possible mechanism. In this study, twenty-four adult male Wister rats were randomly divided into 3 groups: control group, low-dose group (Ag-np, 3 mg/kg) and high-dose group (Ag-np, 30 mg/kg). After two-week exposure to Ag-np through the nasal administration, Morris water maze (MWM) test was performed for the spatial cognition, followed by the long-term potentiation (LTP) recording and reactive oxygen species (ROS) detection in hippocampal homogenate. Results showed that compared with the control group, both LTP and MWM were abnormal in low-dose group and high-dose group. The quantity of ROS in hippocampal homogenate was increased significantly in low-dose group and high-dose group, which may be the reason of the neural damage caused by Ag-np. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  18. A new dynamical atmospheric ionizing radiation (AIR) model for epidemiological studies

    NASA Technical Reports Server (NTRS)

    De Angelis, G.; Clem, J. M.; Goldhagen, P. E.; Wilson, J. W.

    2003-01-01

    A new Atmospheric Ionizing Radiation (AIR) model is currently being developed for use in radiation dose evaluation in epidemiological studies targeted to atmospheric flight personnel such as civilian airlines crewmembers. The model will allow computing values for biologically relevant parameters, e.g. dose equivalent and effective dose, for individual flights from 1945. Each flight is described by its actual three dimensional flight profile, i.e. geographic coordinates and altitudes varying with time. Solar modulated primary particles are filtered with a new analytical fully angular dependent geomagnetic cut off rigidity model, as a function of latitude, longitude, arrival direction, altitude and time. The particle transport results have been obtained with a technique based on the three-dimensional Monte Carlo transport code FLUKA, with a special procedure to deal with HZE particles. Particle fluxes are transformed into dose-related quantities and then integrated all along the flight path to obtain the overall flight dose. Preliminary validations of the particle transport technique using data from the AIR Project ER-2 flight campaign of measurements are encouraging. Future efforts will deal with modeling of the effects of the aircraft structure as well as inclusion of solar particle events. Published by Elsevier Ltd on behalf of COSPAR.

  19. Use of computer code for dose distribution studies in A 60CO industrial irradiator

    NASA Astrophysics Data System (ADS)

    Piña-Villalpando, G.; Sloan, D. P.

    1995-09-01

    This paper presents a benchmark comparison between calculated and experimental absorbed dose values tor a typical product, in a 60Co industrial irradiator, located at ININ, México. The irradiator is a two levels, two layers system with overlapping product configuration with activity around 300kCi. Experimental values were obtanied from routine dosimetry, using red acrylic pellets. Typical product was Petri dishes packages, apparent density 0.13 g/cm3; that product was chosen because uniform size, large quantity and low density. Minimum dose was fixed in 15 kGy. Calculated values were obtained from QAD-CGGP code. This code uses a point kernel technique, build-up factors fitting was done by geometrical progression and combinatorial geometry is used for system description. Main modifications for the code were related with source sumilation, using punctual sources instead of pencils and an energy and anisotropic emission spectrums were included. Results were, for maximum dose, calculated value (18.2 kGy) was 8% higher than experimental average value (16.8 kGy); for minimum dose, calculated value (13.8 kGy) was 3% higher than experimental average value (14.3 kGy).

  20. Uncertainty propagation for SPECT/CT-based renal dosimetry in 177Lu peptide receptor radionuclide therapy

    NASA Astrophysics Data System (ADS)

    Gustafsson, Johan; Brolin, Gustav; Cox, Maurice; Ljungberg, Michael; Johansson, Lena; Sjögreen Gleisner, Katarina

    2015-11-01

    A computer model of a patient-specific clinical 177Lu-DOTATATE therapy dosimetry system is constructed and used for investigating the variability of renal absorbed dose and biologically effective dose (BED) estimates. As patient models, three anthropomorphic computer phantoms coupled to a pharmacokinetic model of 177Lu-DOTATATE are used. Aspects included in the dosimetry-process model are the gamma-camera calibration via measurement of the system sensitivity, selection of imaging time points, generation of mass-density maps from CT, SPECT imaging, volume-of-interest delineation, calculation of absorbed-dose rate via a combination of local energy deposition for electrons and Monte Carlo simulations of photons, curve fitting and integration to absorbed dose and BED. By introducing variabilities in these steps the combined uncertainty in the output quantity is determined. The importance of different sources of uncertainty is assessed by observing the decrease in standard deviation when removing a particular source. The obtained absorbed dose and BED standard deviations are approximately 6% and slightly higher if considering the root mean square error. The most important sources of variability are the compensation for partial volume effects via a recovery coefficient and the gamma-camera calibration via the system sensitivity.

  1. Survival of Chinese Hamster Ovary Cells Following Ultrahigh Dose Rate Electron and Bremsstrahlung Radiation

    DTIC Science & Technology

    1990-04-01

    and a stepped lead flattening filter. The electron energy used for these studies was 13 MeV. Dosimetry was performed by the Health Physics Division...VolI LJSAFSAPA-TR-90-4 AD-A222 722 SURVIVAL OF CHINESE HAMSTER OVARY CELLS FOLLOWING ULTRAHIGH DOSE RATE ELECTRON AND BREMISSTRAHLUNG RADIATION...Include Security ;a!. iatcn) Survival of Chinese Hamster Ovary Cells Following Ultrahigh Dose Rate Electron and Bremsstrahlung Radiation 12 PERSONAL

  2. 10 CFR 32.53 - Luminous safety devices for use in aircraft: Requirements for license to manufacture, assemble...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... maximum quantity of tritium or promethium-147 in each device; (2) Details of construction and design; (3... experimental studies and tests, required by the Commission to facilitate a determination of the safety of the... contact by any person with it; (3) The device is so designed that it cannot easily be disassembled; and (4...

  3. 10 CFR 32.53 - Luminous safety devices for use in aircraft: Requirements for license to manufacture, assemble...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... maximum quantity of tritium or promethium-147 in each device; (2) Details of construction and design; (3... experimental studies and tests, required by the Commission to facilitate a determination of the safety of the... contact by any person with it; (3) The device is so designed that it cannot easily be disassembled; and (4...

  4. 10 CFR 32.53 - Luminous safety devices for use in aircraft: Requirements for license to manufacture, assemble...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... maximum quantity of tritium or promethium-147 in each device; (2) Details of construction and design; (3... experimental studies and tests, required by the Commission to facilitate a determination of the safety of the... contact by any person with it; (3) The device is so designed that it cannot easily be disassembled; and (4...

  5. Reducing Operating Costs by Optimizing Space in Facilities

    DTIC Science & Technology

    2012-03-01

    Base level 5 engineering units will provide facility floor plans, furniture layouts, and staffing documentation as necessary. One obstacle...due to the quantity and diverse locations. Base level engineering units provided facility floor plans, furniture layouts, and staffing documentation... furniture purchases and placement 5. Follow a quality systematic process in all decisions The per person costs can be better understood with a real

  6. Dynamically accumulated dose and 4D accumulated dose for moving tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li Heng; Li Yupeng; Zhang Xiaodong

    2012-12-15

    Purpose: The purpose of this work was to investigate the relationship between dynamically accumulated dose (dynamic dose) and 4D accumulated dose (4D dose) for irradiation of moving tumors, and to quantify the dose uncertainty induced by tumor motion. Methods: The authors established that regardless of treatment modality and delivery properties, the dynamic dose will converge to the 4D dose, instead of the 3D static dose, after multiple deliveries. The bounds of dynamic dose, or the maximum estimation error using 4D or static dose, were established for the 4D and static doses, respectively. Numerical simulations were performed (1) to prove themore » principle that for each phase, after multiple deliveries, the average number of deliveries for any given time converges to the total number of fractions (K) over the number of phases (N); (2) to investigate the dose difference between the 4D and dynamic doses as a function of the number of deliveries for deliveries of a 'pulsed beam'; and (3) to investigate the dose difference between 4D dose and dynamic doses as a function of delivery time for deliveries of a 'continuous beam.' A Poisson model was developed to estimate the mean dose error as a function of number of deliveries or delivered time for both pulsed beam and continuous beam. Results: The numerical simulations confirmed that the number of deliveries for each phase converges to K/N, assuming a random starting phase. Simulations for the pulsed beam and continuous beam also suggested that the dose error is a strong function of the number of deliveries and/or total deliver time and could be a function of the breathing cycle, depending on the mode of delivery. The Poisson model agrees well with the simulation. Conclusions: Dynamically accumulated dose will converge to the 4D accumulated dose after multiple deliveries, regardless of treatment modality. Bounds of the dynamic dose could be determined using quantities derived from 4D doses, and the mean dose difference between the dynamic dose and 4D dose as a function of number of deliveries and/or total deliver time was also established.« less

  7. Personal Computer Transport Analysis Program

    NASA Technical Reports Server (NTRS)

    DiStefano, Frank, III; Wobick, Craig; Chapman, Kirt; McCloud, Peter

    2012-01-01

    The Personal Computer Transport Analysis Program (PCTAP) is C++ software used for analysis of thermal fluid systems. The program predicts thermal fluid system and component transients. The output consists of temperatures, flow rates, pressures, delta pressures, tank quantities, and gas quantities in the air, along with air scrubbing component performance. PCTAP s solution process assumes that the tubes in the system are well insulated so that only the heat transfer between fluid and tube wall and between adjacent tubes is modeled. The system described in the model file is broken down into its individual components; i.e., tubes, cold plates, heat exchangers, etc. A solution vector is built from the components and a flow is then simulated with fluid being transferred from one component to the next. The solution vector of components in the model file is built at the initiation of the run. This solution vector is simply a list of components in the order of their inlet dependency on other components. The component parameters are updated in the order in which they appear in the list at every time step. Once the solution vectors have been determined, PCTAP cycles through the components in the solution vector, executing their outlet function for each time-step increment.

  8. Exploring an interaction of adenosine A2A receptor variability with coffee and tea intake in Parkinson's disease.

    PubMed

    Tan, E K; Lu, Z Y; Fook-Chong, S M C; Tan, E; Shen, H; Chua, E; Yih, Y; Teo, Y Y; Zhao, Y

    2006-09-05

    Caffeine is an adenosine receptor A1 and A2A receptor antagonist and a putative functional genetic variant of the A2A receptor (2592C > Tins) mediates caffeine-induced anxiety. Here we investigated the potential interaction of this A2A genetic variant with the quantity of coffee and tea intake and their relationship with the risk of PD. A total of 441 subjects consisting of 222 PD and 219 race, gender and age matched controls were included. A multivariate analysis of the variables including the 2592C > Tins A2A genotypes, age of onset, gender, and the quantity of tea and coffee intake, interaction of the A2A genotypes with coffee intake, interaction of A2A genotypes with tea intake demonstrated the quantity of coffee intake to be significantly associated with PD (P < 0.0005, OR = 0.922, 95% CI: 0.881, 0.964). However, there was no significant interaction of the A2A genotypes with the quantity of coffee and tea intake in modulating the risk of PD. The dose dependent protective effect of coffee intake in PD was independent of the 2592C > Tins A2A genotype suggesting that the pharmacogenetic action of caffeine in PD may be mediated differently from other caffeine-induced neurologic syndromes.

  9. Effect of Increased Cyclic AMP Concentration on Muscle Protein Synthesis and Beta-Adrenergic Receptor Expression in Chicken Skeletal Muscle Cells in Culture

    NASA Technical Reports Server (NTRS)

    Young, R. B.; Vaughn, J. R.; Bridge, K. Y.; Smith, C. K.

    1998-01-01

    Analogies of epinephrine are known to cause hypertrophy of skeletal muscle when fed to animals. These compounds presumably exert their physiological action through interaction with the P-adrenergic receptor. Since the intracellular signal generated by the Beta-adrenergic receptor is cyclic AMP (cAMP), experiments were initiated in cell culture to determine if artificial elevation of cAMP by treatment with forskolin would alter muscle protein metabolism and P-adrenergic receptor expression. Chicken skeletal muscle cells after 7 days in culture were treated with 0.2-30 micrometers forskolin for a total of three days. At the end of the treatment period, both the concentration of cAMP and the quantity of myosin heavy chain (MHC) were measured. Concentration of cAMP in forskolin-treated cells increased up to 10-fold in a dose dependent manner. In contrast, the quantity of MHC was increased approximately 50% above control cells at 0.2 micrometers forskolin, but exhibited a gradual decline at higher levels of forskolin so that the quantity of MHC in cells treated with 30 micrometers forskolin was not significantly different from controls. Curiously, the intracellular concentration of cAMP which elicited the maximum increase in the quantity of MHC was only 40% higher than cAMP concentration in control cells.

  10. Patient-specific FDG dosimetry for adult males, adult females, and very low birth weight infants

    NASA Astrophysics Data System (ADS)

    Niven, Erin

    Fluorodeoxyglucose is the most commonly used radiopharmaceutical in Positron Emission Tomography, with applications in neurology, cardiology, and oncology. Despite its routine use worldwide, the radiation absorbed dose estimates from FDG have been based primarily on data obtained from two dogs studied in 1977 and 11 adults (most likely males) studied in 1982. In addition, the dose estimates calculated for FDG have been centered on the adult male, with little or no mention of variations in the dose estimates due to sex, age, height, weight, nationality, diet, or pathological condition. Through an extensive investigation into the Medical Internal Radiation Dose schema for calculating absorbed doses, I have developed a simple patient-specific equation; this equation incorporates the parameters necessary for alterations to the mathematical values of the human model to produce an estimate more representative of the individual under consideration. I have used this method to determine the range of absorbed doses to FDG from the collection of a large quantity of biological data obtained in adult males, adult females, and very low birth weight infants. Therefore, a more accurate quantification of the dose to humans from FDG has been completed. My results show that per unit administered activity, the absorbed dose from FDG is higher for infants compared to adults, and the dose for adult women is higher than for adult men. Given an injected activity of approximately 3.7 MBq kg-1, the doses for adult men, adult women, and full-term newborns would be on the order of 5.5, 7.1, and 2.8 mSv, respectively. These absorbed doses are comparable to the doses received from other nuclear medicine procedures.

  11. X-ray BodySearch eliminates strip search in Montana prison

    NASA Astrophysics Data System (ADS)

    de Moulpied, David S.; Rothschild, Peter J.; Smith, Gerald J.

    1998-12-01

    Work release details at prisons have been a continuing source of inspection problems for prison wardens. At the Montana State Prison in deer Lodge 400 prisoners leave the prison in the morning to work outside the walls. They return at lunch and again in the evening. Past practice has been to do a 100% pat search and selective strip searches. These procedures are an irritant to both prisoners and prison personnel involved. However, they were felt to be essential based on the quantity of contraband materials being brought into the prison by these work release inmates. BodySearch is an x-ray scanning system which uses backscatter x-ray to form an image of prisoners as they stand next to the system. Typically prisoners are scanned two at a time, with one scan being taken from the back and the second from the front. Although privacy was considered to be an issue, the prisoners have been relived not to have to go through full pat searches and periodic strip searches. The automatic equipment has also sped up the inspection process and eliminated some of the waiting lines. The problem was so bad that one warden was contemplating having all prisoners issued two sets of clothing (a several hundred thousand dollar investment), which they would change on the way in and out of the prison facility. The new system has all but eliminated any attempt by prisoners to smuggle contraband into the prison by concealing it on their person as they return from work detail. Operationally, a pencil beam is generated by a rotating chopper, which scans horizontally as it is moved vertically. Scintillator detectors mounted adjacent and parallel to the direction of the scanning beam collect the scattered radiation. The result is a photo-like image of the body surface facing the system. The use of a scanning pencil beam in a backscatter geometry with a 140 kV x-ray source eliminates any issue of radiation safety. In fact, the dose delivered by the system (under 10 micro rem for a two-scan inspection) is less than 1% of the dose a person standing outside at sea level receives from background radiation in a day.

  12. SU-E-J-198: Out-Of-Field Dose and Surface Dose Measurements of MRI-Guided Cobalt-60 Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lamb, J; Agazaryan, N; Cao, M

    2015-06-15

    Purpose: To measure quantities of dosimetric interest in an MRI-guided cobalt radiotherapy machine that was recently introduced to clinical use. Methods: Out-of-field dose due to photon scatter and leakage was measured using an ion chamber and solid water slabs mimicking a human body. Surface dose was measured by irradiating stacks of radiochromic film and extrapolating to zero thickness. Electron out-of-field dose was characterized using solid water slabs and radiochromic film. Results: For some phantom geometries, up to 50% of Dmax was observed up to 10 cm laterally from the edge of the beam. The maximum penetration was between 1 andmore » 2 mm in solid water, indicating an electron energy not greater than approximately 0.4 MeV. Out-of-field dose from photon scatter measured at 1 cm depth in solid water was found to fall to less than 10% of Dmax at a distance of 1.2 cm from the edge of a 10.5 × 10.5 cm field, and less that 1% of Dmax at a distance of 10 cm from field edge. Surface dose was measured to be 8% of Dmax. Conclusion: Surface dose and out-of-field dose from the MRIguided cobalt radiotherapy machine was measured and found to be within acceptable limits. Electron out-of-field dose, an effect unique to MRI-guided radiotherapy and presumed to arise from low-energy electrons trapped by the Lorentz force, was quantified. Dr. Low is a member of the scientific advisory board of ViewRay, Inc.« less

  13. Dose of radiation enhancement, using silver nanoparticles in a human tissue equivalent gel dosimeter.

    PubMed

    Hassan, Muhammad; Waheed, Muhammad Mohsin; Anjum, Muhammad Naeem

    2016-01-01

    To quantify the radiation dose enhancement in a human tissue-equivalent polymer gel impregnated with silver nanoparticles. The case-control study was conducted at the Bahawalpur Institute of Nuclear Medicine and Oncology, Bahawalpur, Pakistan, in January 2014. Silver nanoparticles used in this study were prepared by wet chemical method. Polymer gel was prepared by known quantity of gelatine, methacrylic acid, ascorbic acid, copper sulphate pentahydrate, hydroquinone and water. Different concentrations of silver nanoparticles were added to the gel during its cooling process. The gel was cooled in six plastic vials of 50ml each. Two vials were used as a control sample while four vials were impregnated with silver nanoparticles. After 22 hours, the vials were irradiated with gamma rays by aCobalt-60 unit. Radiation enhancement was assessed by taking magnetic resonance images of the vials. The images were analysed using Image J software. The dose enhancement factor was 24.17% and 40.49% for 5Gy and 10Gy dose respectively. The dose enhancement factor for the gel impregnated with 0.10mM silver nanoparticles was 32.88% and 51.98% for 5Gy and 10Gy dose respectively. The impregnation of a tissue-equivalent gel with silver nanoparticles resulted in dose enhancement and this effect was magnified up to a certain level with the increase in concentration of silver nanoparticles.

  14. Comparison of Gavage, Water Bottle, and a High-Moisture Diet Bolus as Dosing Methods for Quantitative D-xylose Administration to B6D2F1 (Mus musculus) Mice

    NASA Technical Reports Server (NTRS)

    Zimmer, J. Paul; Lewis, Sherry M.; Moyer, Jerry L.

    1993-01-01

    Gavage, water bottle, and diet incorporation are 3 dosing methods used orally to administer test compounds to rodents. These 3 methods were compared in mice to determine which represented the most quantitative delivery system. For dietary incorporation, a high-moisture bolus form of NIH-31 rodent meal was developed using hydroxypropyl methylcellulose as an autoclave-stable binding agent. A high-moisture bolus were selected to increase the acceptability of the dosed diet and to promote quantitative consumption through reduced wastage. The test compound used was D-xylose, a pentose sugar that may be quantitatively detected, colorimetrically, in urine following oral dosing. Six male and 6 female B6D2FI mice were placed in metabolism cages and dosed with a known quantity of D-xylose by each of the 3 methods. Urine was collected before and after each method of administration and analysed for total D-xylose; the per cent recovery was based upon the amount of D-xylose consumed. Quantitative consumption was apparently greatest for water bottle dosing with an average recovery of 56.0% of the original D-xylose dose. High-moisture bolus incorporation ranked second with 50.0% D-xylose recovery, and gavage was third with 41.0% D-xylose recovery.

  15. Absolute dose determination in high-energy electron beams: Comparison of IAEA dosimetry protocols

    PubMed Central

    Sathiyan, S.; Ravikumar, M.

    2008-01-01

    In this study, absorbed doses were measured and compared for high-energy electrons (6, 9, 12, 16, and 20 MeV) using International Atomic Energy Agency (IAEA), Technical Reports Series No. 277 (TRS), TRS 381, and TRS 398 dosimetry protocols. Absolute dose measurements were carried out using FC65-G Farmer chamber and Nordic Association of Clinical Physicists (NACP) parallel plate chamber with DOSE1 electrometer in WP1-D water phantom for reference field size of 15 × 15 cm2 at 100 cm source-to-surface distance. The results show that the difference between TRS 398 and TRS 381 was about 0.24% to 1.3% depending upon the energy, and the maximum difference between TRS 398 and TRS 277 was 1.5%. The use of cylindrical chamber in electron beam gives the maximum dose difference between the TRS 398 and TRS 277 in the order of 1.4% for energies above 10 MeV (R50 > 4 g/cm2). It was observed that the accuracy of dose estimation was better with the protocols based on the water calibration procedures, as no conversion quantities are involved for conversion of dose from air to water. The cross-calibration procedure of parallel plate chamber with high-energy electron beams is recommended as it avoids pwall correction factor entering into the determination of kQ,Qo. PMID:19893700

  16. [The use of the FISH method for the cytogenetic examination of persons with a history of acute radiation sickness in connection with the accident at the Chernobyl Atomic Electric Power Station].

    PubMed

    Pilinskaia, M A; Dybskiĭ, S S; Khaliavka, I G

    1998-01-01

    We have performed conventional cytogenetics with group karyotyping and FISH analysis on metaphase-arrested lymphocyte cultured from 13 adults of 23 to 50 years. Twelve Chernobyl accident liquidators of 1986 year recovered from acute radiation sickness of the first (3 persons), second (7 persons) and third (2 persons) degree of severity; and one unexposed (control) person. A cocktail containing a balanced mix of directly-labeled by Spectrum orange whole-chromosome probes for human chromosomes 1,2 and 4 were used. Under the conventional staining the positive correlation between the frequency of chromosome type aberration (acentrics, dicentrics, centric rings, abnormal monocentrics) and the severity of irradiation was established even 10 years after radiation exposure. Under the FISH analysis the frequency of reciprocal translocation was in the range from 0.061 to 0.729 per cell which corresponded to doses of acute uniform irradiation from 0.8 till 3.48 Gy. The data obtained confirmed the validity of FISH as for quantifying stable chromosome aberrations in peripheral lymphocytes of irradiated persons as the high sensitivity of FISH for the retrospective dose evaluation in delayed terms after radiation exposure.

  17. Medical dosimetry in Hungary

    NASA Astrophysics Data System (ADS)

    Turák, O.; Osvay, M.; Ballay, L.

    2012-09-01

    Radiation exposure of medical staff during cardiological and radiological procedures was investigated. The exposure of medical staff is directly connected to patient exposure. The aim of this study was to determine the distribution of doses on uncovered part of body of medical staff using LiF thermoluminescent (TL) dosimeters in seven locations. Individual Kodak film dosimeters (as authorized dosimetry system) were used for the assessment of medical staff's effective dose. Results achieved on dose distribution measurements confirm that wearing only one film badge under the lead apron does not provide enough information on the personal dose. The value of estimated annual doses on eye lens and extremities (fingers) were in good correlation with international publications.

  18. Ambient Dose Equivalent in S. Paulo and Bauru cities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Umisedo, Nancy K.; Okuno, Emico; Cancio, Francisco S.

    2008-08-07

    The Laboratory of Dosimetry (Institute of Physics, University of S. Paulo) performs since 1981 the external individual monitoring of workers exposed to X and gamma rays based on thermoluminescent dosimetry (TLD). Personal dose equivalent refers only to the exposure of workers due to the working activities, and the dose due to background radiation, also measured with TLD, must be subtracted to evaluate it. A compilation of ambient dose equivalent was done to evaluate the dose due to the background radiation in the work places, and also to contribute to the knowledge of the level of indoor radiation to which themore » public is exposed.« less

  19. SU-F-19A-10: Recalculation and Reporting Clinical HDR 192-Ir Head and Neck Dose Distributions Using Model Based Dose Calculation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carlsson Tedgren, A; Persson, M; Nilsson, J

    Purpose: To retrospectively re-calculate dose distributions for selected head and neck cancer patients, earlier treated with HDR 192Ir brachytherapy, using Monte Carlo (MC) simulations and compare results to distributions from the planning system derived using TG43 formalism. To study differences between dose to medium (as obtained with the MC code) and dose to water in medium as obtained through (1) ratios of stopping powers and (2) ratios of mass energy absorption coefficients between water and medium. Methods: The MC code Algebra was used to calculate dose distributions according to earlier actual treatment plans using anonymized plan data and CT imagesmore » in DICOM format. Ratios of stopping power and mass energy absorption coefficients for water with various media obtained from 192-Ir spectra were used in toggling between dose to water and dose to media. Results: Differences between initial planned TG43 dose distributions and the doses to media calculated by MC are insignificant in the target volume. Differences are moderate (within 4–5 % at distances of 3–4 cm) but increase with distance and are most notable in bone and at the patient surface. Differences between dose to water and dose to medium are within 1-2% when using mass energy absorption coefficients to toggle between the two quantities but increase to above 10% for bone using stopping power ratios. Conclusion: MC predicts target doses for head and neck cancer patients in close agreement with TG43. MC yields improved dose estimations outside the target where a larger fraction of dose is from scattered photons. It is important with awareness and a clear reporting of absorbed dose values in using model based algorithms. Differences in bone media can exceed 10% depending on how dose to water in medium is defined.« less

  20. Local patient dose diagnostic reference levels in pediatric interventional cardiology in Chile using age bands and patient weight values

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ubeda, Carlos, E-mail: cubeda@uta.cl; Miranda, Patricia; Vano, Eliseo

    Purpose: To present the results of a patient dose evaluation program in pediatric cardiology and propose local diagnostic reference levels (DRLs) for different types of procedure and age range, in addition to suggesting approaches to correlate patient dose values with patient weight. This study was the first conducted in Latin America for pediatric interventional cardiology under the auspices of the International Atomic Energy Agency. Methods: Over three years, the following data regarding demographic and patient dose values were collected: age, gender, weight, height, number of cine series, total number of cine frames, fluoroscopy time (FT), and two dosimetric quantities, dose-areamore » product (DAP) and cumulative dose (CD), at the patient entrance reference point. The third quartile values for FT, DAP, CD, number of cine series, and the DAP/body weight ratio were proposed as the set of quantities to use as local DRLs. Results: Five hundred and seventeen patients were divided into four age groups. Sample sizes by age group were 120 for <1 yr; 213 for 1 to <5 yr; 82 for 5 to <10 yr; and 102 for 10 to <16 yr. The third quartile values obtained for DAP by diagnostic and therapeutic procedures and age range were 1.17 and 1.11 Gy cm{sup 2} for <1 yr; 1.74 and 1.90 Gy cm{sup 2} for 1 to <5 yr; 2.83 and 3.22 Gy cm{sup 2} for 5 to <10 yr; and 7.34 and 8.68 Gy cm{sup 2} for 10 to <16 yr, respectively. The third quartile value obtained for the DAP/body weight ratio for the full sample of procedures was 0.17 (Gy cm{sup 2}/kg) for diagnostic and therapeutic procedures. Conclusions: The data presented in this paper are an initial attempt at establishing local DRLs in pediatric interventional cardiology, from a large sample of procedures for the standard age bands used in Europe, complemented with the values of the ratio between DAP and patient weight. This permits a rough estimate of DRLs for different patient weights and the refining of these values for the age bands when there may be large differences in child size. These DRLs were obtained at the largest pediatric hospital in Chile, with an active optimization program, and could be used by other hospitals in the Latin America region to compare their current patient dose values and determine whether corrective action is appropriate.« less

Top