A simple method for calculating the characteristics of the Dutch roll motion of an airplane
NASA Technical Reports Server (NTRS)
Klawans, Bernard B
1956-01-01
A simple method for calculating the characteristics of the Dutch roll motion of an airplane is obtained by arranging the lateral equations of motion in such form and order that an iterative process is quickly convergent.
Lipid Extraction and Cholesterol Quantification: A Simple Protocol
ERIC Educational Resources Information Center
Barreto, M. Carmo
2005-01-01
Enzymatic methods are used to measure cholesterol levels but a simple and inexpensive method is described, which is particularly important when one has repeated lab sessions during the week. It can be carried out on the organic phase containing the lipids, without evaporating the solvent, yielding quick results.
A simple technique for obtaining future climate data inputs for natural resource models
USDA-ARS?s Scientific Manuscript database
Those conducting impact studies using natural resource models need to be able to quickly and easily obtain downscaled future climate data from multiple models, scenarios, and timescales for multiple locations. This paper describes a method of quickly obtaining future climate data over a wide range o...
Song, Chihong; Lee, Ju Huck; Jun, Sangmi; Chung, Jeong Min; Hyun, Jaekyung; Jung, Hyun Suk
2016-05-01
The preparation of biological specimens using cryofixation techniques ensures excellent visibility of intracellular structures and preserves the antigenic sites of subcellular molecules. Hence, cryofixation is an effective method of preparing samples for analyses using antibodies conjugated to gold nanoparticles that are designed to detect the localization of specific target molecules within cells. However, cryofixation cannot be utilized easily because it requires expensive equipment and skilled technologists, resulting in a high level of expense for researchers. Here, we describe a simple technical approach to cryofixation that uses metal contact quick freezing followed by a modified freeze substitution technique and immuno-gold labeling electron microscopy. Micrograph images of cells prepared using this modified cryofixation method demonstrated its superiority over chemical fixation for high contrast visualization of the morphologies of cellular components and preservation of antigenicity for immuno-gold labeling. This report provides valuable technical information related to the advancement of metal contact quick freezing techniques, which can be used to visualize biomedical events of interest in an easy, simple, and rapid manner.
Simple method for quick estimation of aquifer hydrogeological parameters
NASA Astrophysics Data System (ADS)
Ma, C.; Li, Y. Y.
2017-08-01
Development of simple and accurate methods to determine the aquifer hydrogeological parameters was of importance for groundwater resources assessment and management. Aiming at the present issue of estimating aquifer parameters based on some data of the unsteady pumping test, a fitting function of Theis well function was proposed using fitting optimization method and then a unitary linear regression equation was established. The aquifer parameters could be obtained by solving coefficients of the regression equation. The application of the proposed method was illustrated, using two published data sets. By the error statistics and analysis on the pumping drawdown, it showed that the method proposed in this paper yielded quick and accurate estimates of the aquifer parameters. The proposed method could reliably identify the aquifer parameters from long distance observed drawdowns and early drawdowns. It was hoped that the proposed method in this paper would be helpful for practicing hydrogeologists and hydrologists.
Testing a simple field method for assessing nitrate removal in riparian zones
Philippe Vidon; Michael G. Dosskey
2008-01-01
Being able to identify riparian sites that function better for nitrate removal from groundwater is critical to using efficiently the riparian zones for water quality management. For this purpose, managers need a method that is quick, inexpensive, and accurate enough to enable effective management decisions. This study assesses the precision and accuracy of a simple...
ERIC Educational Resources Information Center
Sheridan, Philip
1978-01-01
A quick, simple method for preserving bird specimens using borax and a formalin solution is described. Procedures for injecting and mounting the specimens are given along with certain restrictions on preserving specimens. (MA)
Simple Flame Test Techniques Using Cotton Swabs
ERIC Educational Resources Information Center
Sanger, Michael J.; Phelps, Amy J.; Banks, Catherine
2004-01-01
Three alternative methods for performing flame tests using cheaply and easily available cotton swabs are described. These flame tests are useful for chemical demonstrations or laboratory experiments because they are quick and easy to perform with easy cleanup and disposal methods.
Simplified three microphone acoustic test method
USDA-ARS?s Scientific Manuscript database
Accepted acoustic testing standards are available; however, they require specialized hardware and software that are typically out of reach economically to the occasional practitioner. What is needed is a simple and inexpensive screening method that could provide a quick comparison for rapid identifi...
Galy, Bertrand; Lan, André
2018-03-01
Among the many occupational risks construction workers encounter every day falling from a height is the most dangerous. The objective of this article is to propose a simple analytical design method for horizontal lifelines (HLLs) that considers anchorage flexibility. The article presents a short review of the standards and regulations/acts/codes concerning HLLs in Canada the USA and Europe. A static analytical approach is proposed considering anchorage flexibility. The analytical results are compared with a series of 42 dynamic fall tests and a SAP2000 numerical model. The experimental results show that the analytical method is a little conservative and overestimates the line tension in most cases with a maximum of 17%. The static SAP2000 results show a maximum 2.1% difference with the analytical method. The analytical method is accurate enough to safely design HLLs and quick design abaci are provided to allow the engineer to make quick on-site verification if needed.
Covering Cavities by Electrodeposition
NASA Technical Reports Server (NTRS)
Schmeets, M.; Duesberg, J.
1986-01-01
Reworking technique allows complex surfaces to be reshaped. Contours of large machined parts reworked quickly and inexpensively by electrodeposition and machining, with little risk of damage. Reworking method employs simple, reliable, well-known procedures.
Rapid field method for determining the polish susceptibility of carbonate aggregates.
DOT National Transportation Integrated Search
1974-08-01
A quick and simple method by which limestones and related carbonate : paving aggregates can be rated as to their relative susceptibility to : polishing has been successfully applied to a wide number of aggregate : sources used on Texas Highway projec...
A simple method to locate changes in vegetation cover, which can be used to identify areas under stress. The method only requires inexpensive NDVI data. The use of remotely sensed data is far more cost-effective than field studies and can be performed more quickly. Local knowledg...
Simplified Processing Method for Meter Data Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fowler, Kimberly M.; Colotelo, Alison H. A.; Downs, Janelle L.
2015-11-01
Simple/Quick metered data processing method that can be used for Army Metered Data Management System (MDMS) and Logistics Innovation Agency data, but may also be useful for other large data sets. Intended for large data sets when analyst has little information about the buildings.
This work describes a method for using spreadsheet analyses of process designs and retrofits to provide simple and quick economic and environmental evaluations simultaneously. The method focuses attention onto those streams and components that have the largest monetary values and...
Simplified through-transmission test method for determination of a material's acoustic properties
USDA-ARS?s Scientific Manuscript database
Accepted acoustic testing standards are available; however, they require specialized hardware and software that are typically out of reach economically to the occasional practitioner. What is needed is a simple and inexpensive screening method that can provide a quick comparison for rapid identifica...
NASA Astrophysics Data System (ADS)
Rasmeni, Zelda; Pan, Xiaowei
2017-07-01
The Quick-E-Scan methodology is a simple and quick method that is used to achieve operational energy efficiency as opposed to detailed energy audits, which therefore offers a no cost or less cost solutions for energy management programs with a limited budget. The quick-E-scan methodology was used to assesses a steel foundry plant based in Benoni through dividing the foundry into production sections which entailed a review of the current processes and usage patterns of energy within the plant and a detailed analysis of options available for improvement and profitable areas in which energy saving measures may be implemented for an increase energy efficiency which can be presented to management of the company.
Program helps quickly calculate deviated well path
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gardner, M.P.
1993-11-22
A BASIC computer program quickly calculates the angle and measured depth of a simple directional well given only the true vertical depth and total displacement of the target. Many petroleum engineers and geologists need a quick, easy method to calculate the angle and measured depth necessary to reach a target in a proposed deviated well bore. Too many of the existing programs are large and require much input data. The drilling literature is full of equations and methods to calculate the course of well paths from surveys taken after a well is drilled. Very little information, however, covers how tomore » calculate well bore trajectories for proposed wells from limited data. Furthermore, many of the equations are quite complex and difficult to use. A figure lists a computer program with the equations to calculate the well bore trajectory necessary to reach a given displacement and true vertical depth (TVD) for a simple build plant. It can be run on an IBM compatible computer with MS-DOS version 5 or higher, QBasic, or any BASIC that does no require line numbers. QBasic 4.5 compiler will also run the program. The equations are based on conventional geometry and trigonometry.« less
Omura, Yoshiaki; Lu, Dominic; O'Young, Brian; Jones, Marilyn; Nihrane, Abdallah; Duvvi, Harsha; Shimotsuura, Yasuhiro; Ohki, Motomu
2015-01-01
There are many methods of detecting cancers including detection of cancer markers by blood test, (which is invasive, time consuming and relatively expensive), detection of cancers by non-invasive methods such as X-Ray, CT scan, and MRI & PET Scan (which are non-invasive and quick but very expensive). Our research was performed to develop new non-invasive, safe, quick economical method of detecting cancers and the 1st author already developed for clinically important non-invasive new methods including early stage of present method using his method of localizing accurate organ representation areas of face, eyebrows, upper lip, lower lip, surface and dorsal part of the tongue, surface backs, and palm side of the hands. This accurate localization of the organ representation area of the different parts of the body was performed using electromagnetic field resonance phenomenon between 2 identical molecules or tissues based on our US patented non-invasive method in 1993. Since year 2000, we developed the following non-invasive diagnostic methods that can be quickly identified by the patented simple non-invasive method without using expensive or bulky instrument at any office or field where there is no electricity or instrument available. The following are examples of non-invasive quick method of diagnosis and treatment of cancers using different approaches: 1) Soft red laser beam scanning of different parts of body; 2) By speaking voice; 3) Visible and invisible characteristic abnormalities on different organ representation areas of the different parts of the body, and 4) Mouth, Hand, and Foot Writings of both right and left side of the body. As a consequence of our latest research, we were able to develop a simple method of detecting cancer from existing recorded electrocardiograms. In this article, we are going to describe the method and result of clinical applications on many different cancers of different organs including lung, esophagus, breast, stomach, colon, uterus, ovary, prostate gland, as well as common bone marrow related malignancies such as Hodgkin's Lymphoma, Non-Hodgkin's Lymphoma, Multiple Myeloma as well as Leukemia.
CASE STUDIES EXAMINING LCA STREAMLINING TECHNIQUES
Pressure is mounting for more streamlined Life Cycle Assessment (LCA) methods that allow for evaluations that are quick and simple, but accurate. As part of an overall research effort to develop and demonstrate streamlined LCA, the U.S. Environmental Protection Agency has funded ...
Calculating the Degradation Rate of Individual Proteins Using Xenopus Extract Systems.
McDowell, Gary S; Philpott, Anna
2018-05-16
The Xenopus extract system has been used extensively as a simple, quick, and robust method for assessing the stability of proteins against proteasomal degradation. In this protocol, methods are provided for assessing the half-life of in vitro translated radiolabeled proteins using Xenopus egg or embryo extracts. © 2019 Cold Spring Harbor Laboratory Press.
A novel mechanochemical method for reconstructing the moisture-degraded HKUST-1.
Sun, Xuejiao; Li, Hao; Li, Yujie; Xu, Feng; Xiao, Jing; Xia, Qibin; Li, Yingwei; Li, Zhong
2015-07-11
A novel mechanochemical method was proposed to reconstruct quickly moisture-degraded HKUST-1. The degraded HKUST-1 can be restored within minutes. The reconstructed samples were characterized, and confirmed to have 95% surface area and 92% benzene capacity of the fresh HKUST-1. It is a simple and effective strategy for degraded MOF reconstruction.
Menezes, Helvécio C; Paulo, Breno P; Paiva, Maria José N; Cardeal, Zenilda L
2016-01-01
This paper describes a simple and quick method for sampling and also for carrying out the preconcentration of pesticides in environmental water matrices using two-phased hollow fiber liquid phase microextraction (HF-LPME). Factors such as extraction mode, time, solvents, agitation, and salt addition were investigated in order to validate the LPME method. The following conditions were selected: 6 cm of polypropylene hollow fiber, ethyl octanoate as an acceptor phase, and extraction during 30 min under stirring at 200 rpm. The optimized method showed good linearity in the range of 0.14 to 200.00 μ g L -1 ; the determination coefficient ( R 2 ) was in the range of 0.9807-0.9990. The LOD ranged from 0.04 μ g L -1 to 0.44 μ g L -1 , and LOQ ranged from 0.14 μ g L -1 to 1.69 μ g L -1 . The recovery ranged from 85.17% to 114.73%. The method was applied to the analyses of pesticides in three environmental water samples (a spring and few streams) collected in a rural area from the state of Minas Gerais, Brazil.
Chen, Xiaochu; Bian, Yanli; Liu, Fengmao; Teng, Peipei; Sun, Pan
2017-10-06
Two simple sample pretreatment for the determination of difenoconazole in cowpea was developed including micellar extraction combined with ionic liquid based vortex-assisted liquid-liquid microextraction (ME-IL-VALLME) prior to high performance liquid chromatography (HPLC), and modified quick, easy, cheap, effective, rugged, and safe method (QuEChERS) coupled with HPLC-MS/MS. In ME-IL-VALLME method, the target analyte was extracted by surfactant Tween 20 micellar solution, then the supernatant was diluted with 3mL water to decrease the solubility of micellar solution. Subsequently, the vortex-assisted liquid-liquid microextraction (VALLME) procedure was performed in the diluted extraction solution by using the ionic liquid of 1-hexyl-3-methylimidazolium hexafluorophosphate ([HMIM]PF 6 ) as the extraction solvent and Tween 20 as an emulsifier to enhance the dispersion of the water-immiscible ionic liquid into the aqueous phase. Parameters that affect the extraction have been investigated in both methods Under the optimum conditions, the limits of quantitation were 0.10 and 0.05mgkg -1 , respectively. And good linearity was achieved with the correlation coefficient higher than 0.9941. The relative recoveries ranged from 78.6 to 94.8% and 92.0 to 118.0% with the relative standard deviations (RSD) of 7.9-9.6% and 1.2-3.2%, respectively. Both methods were quick, simple and inexpensive. However, the ME-IL-VALLME method provides higher enrichment factor compared with conventional QuEChERS method. The ME-IL-VALLME method has a strong potential for the determination of difenoconazole in complex vegetable matrices with HPLC. Copyright © 2017 Elsevier B.V. All rights reserved.
The acquisition of simple associations as observed in color-word contingency learning.
Lin, Olivia Y-H; MacLeod, Colin M
2018-01-01
Three experiments investigated the learning of simple associations in a color-word contingency task. Participants responded manually to the print colors of 3 words, with each word associated strongly to 1 of the 3 colors and weakly to the other 2 colors. Despite the words being irrelevant, response times to high-contingency stimuli and to low-contingency stimuli quickly diverged. This high-low difference remained quite constant over successive blocks of trials, evidence of stable contingency learning. Inclusion of a baseline condition-an item having no color-word contingency-permitted separation of the contingency learning effect into 2 components: a cost due to low contingency and a benefit due to high contingency. Both cost and benefit were quick to acquire, quick to extinguish, and quick to reacquire. The color-word contingency task provides a simple way to directly study the learning of associations. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Sample Size Estimation: The Easy Way
ERIC Educational Resources Information Center
Weller, Susan C.
2015-01-01
This article presents a simple approach to making quick sample size estimates for basic hypothesis tests. Although there are many sources available for estimating sample sizes, methods are not often integrated across statistical tests, levels of measurement of variables, or effect sizes. A few parameters are required to estimate sample sizes and…
A simple pendulum-based measurement of g with a smartphone light sensor
NASA Astrophysics Data System (ADS)
Pili, Unofre; Violanda, Renante
2018-07-01
A quick and very accessible method for the measurement of acceleration due to gravity is presented. The experimental set-up employs a smartphone ambient light sensor as the motion timer for measuring the period of a simple pendulum. This allowed us to obtain an experimental value, 9.72 + 0.05 m s‑2, for the gravitational acceleration which is in good agreement with the local theoretical value of 9.78 m s‑2.
Paulo, Breno P.; Paiva, Maria José N.
2016-01-01
This paper describes a simple and quick method for sampling and also for carrying out the preconcentration of pesticides in environmental water matrices using two-phased hollow fiber liquid phase microextraction (HF-LPME). Factors such as extraction mode, time, solvents, agitation, and salt addition were investigated in order to validate the LPME method. The following conditions were selected: 6 cm of polypropylene hollow fiber, ethyl octanoate as an acceptor phase, and extraction during 30 min under stirring at 200 rpm. The optimized method showed good linearity in the range of 0.14 to 200.00 μg L−1; the determination coefficient (R 2) was in the range of 0.9807–0.9990. The LOD ranged from 0.04 μg L−1 to 0.44 μg L−1, and LOQ ranged from 0.14 μg L−1 to 1.69 μg L−1. The recovery ranged from 85.17% to 114.73%. The method was applied to the analyses of pesticides in three environmental water samples (a spring and few streams) collected in a rural area from the state of Minas Gerais, Brazil. PMID:27774336
Ströher, Patrícia R.; Firkowski, Carina R.; Freire, Andrea S.; Pie, Marcio R.
2011-01-01
The decapod Grapsus grapsus is commonly found on oceanic islands of the Pacific and Atlantic coasts of the Americas. In this study, a simple, quick and reliable method for detecting its larvae in plankton samples is described, which makes it ideal for large-scale studies of larval dispersal patterns in the species. PMID:21931530
Endo, Fumiko; Tabata, Tsutomu; Sadato, Daichi; Kawamura, Machiko; Ando, Noriyuki; Ukaji, Masako; Kobayashi, Kaoru; Kobayashi, Yukuharu; Ikeda, Tomoaki; Shibasaki, Futoshi
2017-01-01
Immunochromatography (IC) is widely used to detect target molecules in biological fluids. Since this method can be performed without a special technique or device, IC is a convenient way to assess the existence of antibodies or pathogens such as viruses and bacteria, simply and quickly. In this study, we established an IC method to detect serum antibodies against oncogenic human papillomavirus (HPV)-16 and HPV-18 L1 proteins using recombinant L1 proteins produced by silkworms as antigens. Infection of oncogenic HPVs is a major risk factor of cervical cancer, which is one of the most common cancers in women worldwide. We first measured blood sera of two groups by magnetic beads enzyme-linked immunosorbent assay (MB-ELISA). For the first group, sera were collected prospectively from young women who planned to receive HPV vaccination. The second group consisted of children under 20 years of age, non-vaccinated healthy women, vaccinated healthy women, dysplasia, cervical intraepithelial neoplasia III, and cervical cancer patients. We confirmed that standard vaccination doses significantly increased serum HPV antibody concentrations, and the level was sustained at least more than 30 months after vaccination. In contrast, an increase in antibody concentration was not observed in patients with precancerous cervical changes and cervical cancer. We next measured the samples in both groups using the IC method we originally developed, and found that the measurement values of IC highly correlated with those of MB-ELISA. The simple and quick IC method would be a useful tool for rapid monitoring of L1 specific antibody levels in a non-laboratory environment. With less than one drop of serum, our IC can easily detect serum HPV-16/-18 antibodies within 15 minutes, without the need for electronic devices or techniques. PMID:28158224
The use of National Weather Service Data to Compute the Dose to the MEOI.
Vickers, Linda
2018-05-01
The Turner method is the "benchmark method" for computing the stability class that is used to compute the X/Q (s m). The Turner method should be used to ascertain the validity of X/Q results determined by other methods. This paper used site-specific meteorological data obtained from the National Weather Service. The Turner method described herein is simple, quick, accurate, and transparent because all of the data, calculations, and results are visible for verification and validation with published literature.
Sublaminate analysis of interlaminar fracture in composites
NASA Technical Reports Server (NTRS)
Armanios, E. A.; Rehfield, L. W.
1986-01-01
A simple analysis method based upon a transverse shear deformation theory and a sublaminate approach is utilized to analyze a mixed-mode edge delamination specimen. The analysis provides closed form expressions for the interlaminar shear stresses ahead of the crack, the total energy release rate, and the energy release rate components. The parameters controlling the behavior are identified. The effect of specimen stacking sequence and delamination interface on the strain energy release rate components is investigated. Results are compared with a finite element simulation for reference. The simple nature of the method makes it suitable for preliminary design analyses which require a large number of configurations to be evaluated quickly and economically.
A simple technique for laparoscopic gastrostomy.
Murphy, C; Rosemurgy, A S; Albrink, M H; Carey, L C
1992-05-01
While endoscopically placed gastrostomy tubes are routinely simple, they are not always feasible. Endoscopic technique also does not uniformly secure the tube to the abdominal wall, which presents possible complications, including leakage, accidental early tube removal, intraperitoneal catheter migration and necrosis of the stomach or abdominal wall because of excessive traction. Presented herein is a technique that is rapid, simple and eliminates some of these potential complications. The technique is easily combined with other operative procedures, such as tracheostomy, is done under direct vision, can be performed quickly with intravenous sedation and local anesthetic and is a safe method of tube placement for enteral feeding or gastric decompression.
A Simple, Safe Method for Preparation of Biodiesel
ERIC Educational Resources Information Center
Behnia, Mahin S.; Emerson, David W.; Steinberg, Spencer M.; Alwis, Rasika M.; Duenas, Josue A.; Serafino, Jessica O.
2011-01-01
An experiment suitable for organic chemistry students is described. Biodiesel, a "green" fuel, consists of methyl or ethyl esters of long-chain fatty acids called FAMES (fatty acid methyl esters) or FAEES (fatty acid ethyl esters). A quick way to make FAMES is a base-catalyzed transesterification of oils or fats derived from plants or from animal…
ERIC Educational Resources Information Center
Warkentien, Siri; Silver, David
2016-01-01
Public schools with impressive records of serving lower-performing students are often overlooked because their average test scores, even when students are growing quickly, are lower than scores in schools that serve higher-performing students. Schools may appear to be doing poorly either because baseline achievement is not easily accounted for or…
An integrate-over-temperature approach for enhanced sampling.
Gao, Yi Qin
2008-02-14
A simple method is introduced to achieve efficient random walking in the energy space in molecular dynamics simulations which thus enhances the sampling over a large energy range. The approach is closely related to multicanonical and replica exchange simulation methods in that it allows configurations of the system to be sampled in a wide energy range by making use of Boltzmann distribution functions at multiple temperatures. A biased potential is quickly generated using this method and is then used in accelerated molecular dynamics simulations.
Fast Ordered Sampling of DNA Sequence Variants.
Greenberg, Anthony J
2018-05-04
Explosive growth in the amount of genomic data is matched by increasing power of consumer-grade computers. Even applications that require powerful servers can be quickly tested on desktop or laptop machines if we can generate representative samples from large data sets. I describe a fast and memory-efficient implementation of an on-line sampling method developed for tape drives 30 years ago. Focusing on genotype files, I test the performance of this technique on modern solid-state and spinning hard drives, and show that it performs well compared to a simple sampling scheme. I illustrate its utility by developing a method to quickly estimate genome-wide patterns of linkage disequilibrium (LD) decay with distance. I provide open-source software that samples loci from several variant format files, a separate program that performs LD decay estimates, and a C++ library that lets developers incorporate these methods into their own projects. Copyright © 2018 Greenberg.
A step-by-step solution for embedding user-controlled cines into educational Web pages.
Cornfeld, Daniel
2008-03-01
The objective of this article is to introduce a simple method for embedding user-controlled cines into a Web page using a simple JavaScript. Step-by-step instructions are included and the source code is made available. This technique allows the creation of portable Web pages that allow the user to scroll through cases as if seated at a PACS workstation. A simple JavaScript allows scrollable image stacks to be included on Web pages. With this technique, you can quickly and easily incorporate entire stacks of CT or MR images into online teaching files. This technique has the potential for use in case presentations, online didactics, teaching archives, and resident testing.
A simple technique of laparoscopic port closure.
Aziz, Homayara Haque
2013-01-01
Laparoscopic and robotic surgery is widely practiced in modern medicine. The operative procedure is not complete until the port sites are closed with a fascial suture. We report a simple new technique that is easy, cost-effective, and quick to apply using 2 S-retractors for suture placement under direct visualization to secure the abdominal wall fascia and peritoneum. As a prospective consecutive case series, this technique was used for fascial closure after laparoscopy ports > 8 mm using 2 S-retractors. One S-retractor is used as a barrier protecting the contents of the abdominal cavity, reducing the risk of visceral injuries. The second S-retractor allows us to directly visualize the different layers, exposing the needle tip during its course through the fascia. This method was used in 100 patients with no intraoperative incidents, additional operative time, or need to access costly instruments. Currently, this technique is also used by many surgeons in our institution without any difficulty. No bowel injuries or port-site hernias were reported during a mean follow-up of 6 wk postoperation and 12-mo annual follow-up. The procedure is simple, easy, cost-effective, and quick to apply.
Accurate Simulation of MPPT Methods Performance When Applied to Commercial Photovoltaic Panels
2015-01-01
A new, simple, and quick-calculation methodology to obtain a solar panel model, based on the manufacturers' datasheet, to perform MPPT simulations, is described. The method takes into account variations on the ambient conditions (sun irradiation and solar cells temperature) and allows fast MPPT methods comparison or their performance prediction when applied to a particular solar panel. The feasibility of the described methodology is checked with four different MPPT methods applied to a commercial solar panel, within a day, and under realistic ambient conditions. PMID:25874262
Accurate simulation of MPPT methods performance when applied to commercial photovoltaic panels.
Cubas, Javier; Pindado, Santiago; Sanz-Andrés, Ángel
2015-01-01
A new, simple, and quick-calculation methodology to obtain a solar panel model, based on the manufacturers' datasheet, to perform MPPT simulations, is described. The method takes into account variations on the ambient conditions (sun irradiation and solar cells temperature) and allows fast MPPT methods comparison or their performance prediction when applied to a particular solar panel. The feasibility of the described methodology is checked with four different MPPT methods applied to a commercial solar panel, within a day, and under realistic ambient conditions.
Vanduyfhuys, Louis; Vandenbrande, Steven; Verstraelen, Toon; Schmid, Rochus; Waroquier, Michel; Van Speybroeck, Veronique
2015-05-15
QuickFF is a software package to derive accurate force fields for isolated and complex molecular systems in a quick and easy manner. Apart from its general applicability, the program has been designed to generate force fields for metal-organic frameworks in an automated fashion. The force field parameters for the covalent interaction are derived from ab initio data. The mathematical expression of the covalent energy is kept simple to ensure robustness and to avoid fitting deficiencies as much as possible. The user needs to produce an equilibrium structure and a Hessian matrix for one or more building units. Afterward, a force field is generated for the system using a three-step method implemented in QuickFF. The first two steps of the methodology are designed to minimize correlations among the force field parameters. In the last step, the parameters are refined by imposing the force field parameters to reproduce the ab initio Hessian matrix in Cartesian coordinate space as accurate as possible. The method is applied on a set of 1000 organic molecules to show the easiness of the software protocol. To illustrate its application to metal-organic frameworks (MOFs), QuickFF is used to determine force fields for MIL-53(Al) and MOF-5. For both materials, accurate force fields were already generated in literature but they requested a lot of manual interventions. QuickFF is a tool that can easily be used by anyone with a basic knowledge of performing ab initio calculations. As a result, accurate force fields are generated with minimal effort. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Organizing for low cost space operations - Status and plans
NASA Technical Reports Server (NTRS)
Lee, C.
1976-01-01
Design features of the Space Transportation System (vehicle reuse, low cost expendable components, simple payload interfaces, standard support systems) must be matched by economical operational methods to achieve low operating and payload costs. Users will be responsible for their own payloads and will be charged according to the services they require. Efficient use of manpower, simple documentation, simplified test, checkout, and flight planning are firm goals, together with flexibility for quick response to varying user needs. Status of the Shuttle hardware, plans for establishing low cost procedures, and the policy for user charges are discussed.
Tyson, Adam L.; Hilton, Stephen T.; Andreae, Laura C.
2015-01-01
The cost of 3D printing has reduced dramatically over the last few years and is now within reach of many scientific laboratories. This work presents an example of how 3D printing can be applied to the development of custom laboratory equipment that is specifically adapted for use with the novel brain tissue clearing technique, CLARITY. A simple, freely available online software tool was used, along with consumer-grade equipment, to produce a brain slicing chamber and a combined antibody staining and imaging chamber. Using standard 3D printers we were able to produce research-grade parts in an iterative manner at a fraction of the cost of commercial equipment. 3D printing provides a reproducible, flexible, simple and cost-effective method for researchers to produce the equipment needed to quickly adopt new methods. PMID:25797056
Self-navigation of a scanning tunneling microscope tip toward a micron-sized graphene sample.
Li, Guohong; Luican, Adina; Andrei, Eva Y
2011-07-01
We demonstrate a simple capacitance-based method to quickly and efficiently locate micron-sized conductive samples, such as graphene flakes, on insulating substrates in a scanning tunneling microscope (STM). By using edge recognition, the method is designed to locate and to identify small features when the STM tip is far above the surface, allowing for crash-free search and navigation. The method can be implemented in any STM environment, even at low temperatures and in strong magnetic field, with minimal or no hardware modifications.
Criteria for the Depths of Dredged Navigational Channels.
1983-05-01
can be controlled wLthin 5 ft to 10 ft. Otner fixed-spud plants are grab dredges and dipper dredges. They differ from the cutter suction dredge in...planned on a river mouth or a beach where a big amount of littoral drift is expected, the degree of maintenance dredging required in the future should be...paper presents a relatively simple method which permits a quick estimate of the siltation to be expected witnout the use of a big computer. This method
An overview of longitudinal data analysis methods for neurological research.
Locascio, Joseph J; Atri, Alireza
2011-01-01
The purpose of this article is to provide a concise, broad and readily accessible overview of longitudinal data analysis methods, aimed to be a practical guide for clinical investigators in neurology. In general, we advise that older, traditional methods, including (1) simple regression of the dependent variable on a time measure, (2) analyzing a single summary subject level number that indexes changes for each subject and (3) a general linear model approach with a fixed-subject effect, should be reserved for quick, simple or preliminary analyses. We advocate the general use of mixed-random and fixed-effect regression models for analyses of most longitudinal clinical studies. Under restrictive situations or to provide validation, we recommend: (1) repeated-measure analysis of covariance (ANCOVA), (2) ANCOVA for two time points, (3) generalized estimating equations and (4) latent growth curve/structural equation models.
Optimization of control gain by operator adjustment
NASA Technical Reports Server (NTRS)
Kruse, W.; Rothbauer, G.
1973-01-01
An optimal gain was established by measuring errors at 5 discrete control gain settings in an experimental set-up consisting of a 2-dimensional, first-order pursuit tracking task performed by subjects (S's). No significant experience effect on optimum gain setting was found in the first experiment. During the second experiment, in which control gain was continuously adjustable, high experienced S's tended to reach the previously determined optimum gain quite accurately and quickly. Less experienced S's tended to select a marginally optimum gain either below or above the experimentally determined optimum depending on initial control gain setting, although mean settings of both groups were equal. This quick and simple method is recommended for selecting control gains for different control systems and forcing functions.
A rapid and efficient assay for extracting DNA from fungi
Griffin, Dale W.; Kellogg, C.A.; Peak, K.K.; Shinn, E.A.
2002-01-01
Aims: A method for the rapid extraction of fungal DNA from small quantities of tissue in a batch-processing format was investigated. Methods and Results: Tissue (< 3.0 mg) was scraped from freshly-grown fungal isolates. The tissue was suspended in buffer AP1 and subjected to seven rounds of freeze/thaw using a crushed dry ice/ethanol bath and a boiling water bath. After a 30 min boiling step, the tissue was quickly ground against the wall of the microfuge tube using a sterile pipette tip. The Qiagen DNeasy Plant Tissue Kit protocol was then used to purify the DNA for PCR/ sequencing applications. Conclusions: The method allowed batch DNA extraction from multiple fungal isolates using a simple yet rapid and reliable assay. Significance and Impact of the Study: Use of this assay will allow researchers to obtain DNA from fungi quickly for use in molecular assays that previously required specialized instrumentation, was time-consuming or was not conducive to batch processing.
ERIC Educational Resources Information Center
le Clercq, Carlijn M. P.; van der Schroeff, Marc P.; Rispens, Judith E.; Ruytjens, Liesbet; Goedegebure, André; van Ingen, Gijs; Franken, Marie-Christine
2017-01-01
Purpose: The purpose of this research note was to validate a simplified version of the Dutch nonword repetition task (NWR; Rispens & Baker, 2012). The NWR was shortened and scoring was transformed to correct/incorrect nonwords, resulting in the shortened NWR (NWR-S). Method: NWR-S and NWR performance were compared in the previously published…
Turner, Andrew D; Waack, Julia; Lewis, Adam; Edwards, Christine; Lawton, Linda
2018-02-01
A simple, rapid UHPLC-MS/MS method has been developed and optimised for the quantitation of microcystins and nodularin in wide variety of sample matrices. Microcystin analogues targeted were MC-LR, MC-RR, MC-LA, MC-LY, MC-LF, LC-LW, MC-YR, MC-WR, [Asp3] MC-LR, [Dha7] MC-LR, MC-HilR and MC-HtyR. Optimisation studies were conducted to develop a simple, quick and efficient extraction protocol without the need for complex pre-analysis concentration procedures, together with a rapid sub 5min chromatographic separation of toxins in shellfish and algal supplement tablet powders, as well as water and cyanobacterial bloom samples. Validation studies were undertaken on each matrix-analyte combination to the full method performance characteristics following international guidelines. The method was found to be specific and linear over the full calibration range. Method sensitivity in terms of limits of detection, quantitation and reporting were found to be significantly improved in comparison to LC-UV methods and applicable to the analysis of each of the four matrices. Overall, acceptable recoveries were determined for each of the matrices studied, with associated precision and within-laboratory reproducibility well within expected guidance limits. Results from the formalised ruggedness analysis of all available cyanotoxins, showed that the method was robust for all parameters investigated. The results presented here show that the optimised LC-MS/MS method for cyanotoxins is fit for the purpose of detection and quantitation of a range of microcystins and nodularin in shellfish, algal supplement tablet powder, water and cyanobacteria. The method provides a valuable early warning tool for the rapid, routine extraction and analysis of natural waters, cyanobacterial blooms, algal powders, food supplements and shellfish tissues, enabling monitoring labs to supplement traditional microscopy techniques and report toxicity results within a short timeframe of sample receipt. The new method, now accredited to ISO17025 standard, is simple, quick, applicable to multiple matrices and is highly suitable for use as a routine, high-throughout, fast turnaround regulatory monitoring tool. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Sahoo, Amaresh Kumar; Sharma, Shilpa; Chattopadhyay, Arun; Ghosh, Siddhartha Sankar
2012-02-01
Rapid, simple and sensitive detection of bacterial contamination is critical for safeguarding public health and the environment. Herein, we report an easy method of detection as well as enumeration of the bacterial cell number on the basis of fluorescence quenching of a non-antibacterial fluorescent nanocomposite, consisting of paracetamol dimer (PD) and Au nanoparticles (NPs), in the presence of bacteria. The composite was synthesized by reaction of paracetamol (p-hydroxyacetanilide) with HAuCl4. The Au NPs of the composite were characterized using UV-Vis spectroscopy, transmission electron microscopy (TEM), X-ray diffraction and selected area electron diffraction analysis. The paracetamol dimer in the composite showed emission peak at 435 nm when excited at 320 nm. The method successfully detected six bacterial strains with a sensitivity of 100 CFU mL-1. The Gram-positive and Gram-negative bacteria quenched the fluorescence of the composite differently, making it possible to distinguish between the two. The TEM analysis showed interaction of the composite with bacteria without any apparent damage to the bacteria. The chi-square test established the accuracy of the method. Quick, non-specific and highly sensitive detection of bacteria over a broad range of logarithmic dilutions within a short span of time demonstrates the potential of this method as an alternative to conventional methods.Rapid, simple and sensitive detection of bacterial contamination is critical for safeguarding public health and the environment. Herein, we report an easy method of detection as well as enumeration of the bacterial cell number on the basis of fluorescence quenching of a non-antibacterial fluorescent nanocomposite, consisting of paracetamol dimer (PD) and Au nanoparticles (NPs), in the presence of bacteria. The composite was synthesized by reaction of paracetamol (p-hydroxyacetanilide) with HAuCl4. The Au NPs of the composite were characterized using UV-Vis spectroscopy, transmission electron microscopy (TEM), X-ray diffraction and selected area electron diffraction analysis. The paracetamol dimer in the composite showed emission peak at 435 nm when excited at 320 nm. The method successfully detected six bacterial strains with a sensitivity of 100 CFU mL-1. The Gram-positive and Gram-negative bacteria quenched the fluorescence of the composite differently, making it possible to distinguish between the two. The TEM analysis showed interaction of the composite with bacteria without any apparent damage to the bacteria. The chi-square test established the accuracy of the method. Quick, non-specific and highly sensitive detection of bacteria over a broad range of logarithmic dilutions within a short span of time demonstrates the potential of this method as an alternative to conventional methods. Electronic supplementary information (ESI) available. See DOI: 10.1039/c2nr11837h
An Overview of Longitudinal Data Analysis Methods for Neurological Research
Locascio, Joseph J.; Atri, Alireza
2011-01-01
The purpose of this article is to provide a concise, broad and readily accessible overview of longitudinal data analysis methods, aimed to be a practical guide for clinical investigators in neurology. In general, we advise that older, traditional methods, including (1) simple regression of the dependent variable on a time measure, (2) analyzing a single summary subject level number that indexes changes for each subject and (3) a general linear model approach with a fixed-subject effect, should be reserved for quick, simple or preliminary analyses. We advocate the general use of mixed-random and fixed-effect regression models for analyses of most longitudinal clinical studies. Under restrictive situations or to provide validation, we recommend: (1) repeated-measure analysis of covariance (ANCOVA), (2) ANCOVA for two time points, (3) generalized estimating equations and (4) latent growth curve/structural equation models. PMID:22203825
Microwave (EPR) measurements of the penetration depth measurements of high-Tc superconductors
NASA Technical Reports Server (NTRS)
Dalal, N. S.; Rakvin, B.; Mahl, T. A.; Bhalla, A. S.; Sheng, Z. Z.
1991-01-01
The use is discussed of electron paramagnetic resonance (EPR) as a quick and easily accessible method for measuring the London penetration depth, lambda for the high T sub c superconductors. The method uses the broadening of the EPR signal, due to the emergence of the magnetic flux lattice, of a free radical adsorbed on the surface of the sample. The second moment, of the EPR signal below T sub c is fitted to the Brandt equation for a simple triangular lattice. The precision of this method compares quite favorably with those of the more standard methods such as micro sup(+)SR, neutron scattering, and magnetic susceptibility.
An EPR methodology for measuring the London penetration depth for the ceramic superconductors
NASA Technical Reports Server (NTRS)
Rakvin, B.; Mahl, T. A.; Dalal, N. S.
1990-01-01
The use is discussed of electron paramagnetic resonance (EPR) as a quick and easily accessible method for measuring the London penetration depth, lambda for the high T(sub c) superconductors. The method utilizes the broadening of the EPR signal, due to the emergence of the magnetic flux lattice, of a free radical adsorbed on the surface of the sample. The second moment, of the EPR signal below T(sub c) is fitted to the Brandt equation for a simple triangular lattice. The precision of this method compares quite favorably with those of the more standard methods such as micro sup(+)SR, Neutron scattering, and magnetic susceptibility.
High-speed autofocusing of a cell using diffraction pattern
NASA Astrophysics Data System (ADS)
Oku, Hiromasa; Ishikawa, Masatoshi; Theodorus; Hashimoto, Koichi
2006-05-01
This paper proposes a new autofocusing method for observing cells under a transmission illumination. The focusing method uses a quick and simple focus estimation technique termed “depth from diffraction,” which is based on a diffraction pattern in a defocused image of a biological specimen. Since this method can estimate the focal position of the specimen from only a single defocused image, it can easily realize high-speed autofocusing. To demonstrate the method, it was applied to continuous focus tracking of a swimming paramecium, in combination with two-dimensional position tracking. Three-dimensional tracking of the paramecium for 70 s was successfully demonstrated.
Microcomputer-Assisted Mathematics: From Simple Interest to e.
ERIC Educational Resources Information Center
Kimberling, Clark
1985-01-01
The progression from simple interest to compound interest leads naturally and quickly to the number e, involving mathematical discovery learning through writing programs. Several programs are given, with suggestions for a teaching sequence. (MNS)
Device Rotates Bearing Balls For Inspection
NASA Technical Reports Server (NTRS)
Burley, R. K.
1988-01-01
Entire surface of ball inspected automatically and quickly. Device holds and rotates bearing ball for inspection by optical or mechanical surface-quality probe, eddy-current probe for detection of surface or subsurface defects, or circumference-measuring tool. Ensures entire surface of ball moves past inspection head quickly. New device saves time and increases reliability of inspections of spherical surfaces. Simple to operate and provides quick and easy access for loading and unloading of balls during inspection.
[Baseflow separation methods in hydrological process research: a review].
Xu, Lei-Lei; Liu, Jing-Lin; Jin, Chang-Jie; Wang, An-Zhi; Guan, De-Xin; Wu, Jia-Bing; Yuan, Feng-Hui
2011-11-01
Baseflow separation research is regarded as one of the most important and difficult issues in hydrology and ecohydrology, but lacked of unified standards in the concepts and methods. This paper introduced the theories of baseflow separation based on the definitions of baseflow components, and analyzed the development course of different baseflow separation methods. Among the methods developed, graph separation method is simple and applicable but arbitrary, balance method accords with hydrological mechanism but is difficult in application, whereas time series separation method and isotopic method can overcome the subjective and arbitrary defects caused by graph separation method, and thus can obtain the baseflow procedure quickly and efficiently. In recent years, hydrological modeling, digital filtering, and isotopic method are the main methods used for baseflow separation.
The MOLGENIS toolkit: rapid prototyping of biosoftware at the push of a button
2010-01-01
Background There is a huge demand on bioinformaticians to provide their biologists with user friendly and scalable software infrastructures to capture, exchange, and exploit the unprecedented amounts of new *omics data. We here present MOLGENIS, a generic, open source, software toolkit to quickly produce the bespoke MOLecular GENetics Information Systems needed. Methods The MOLGENIS toolkit provides bioinformaticians with a simple language to model biological data structures and user interfaces. At the push of a button, MOLGENIS’ generator suite automatically translates these models into a feature-rich, ready-to-use web application including database, user interfaces, exchange formats, and scriptable interfaces. Each generator is a template of SQL, JAVA, R, or HTML code that would require much effort to write by hand. This ‘model-driven’ method ensures reuse of best practices and improves quality because the modeling language and generators are shared between all MOLGENIS applications, so that errors are found quickly and improvements are shared easily by a re-generation. A plug-in mechanism ensures that both the generator suite and generated product can be customized just as much as hand-written software. Results In recent years we have successfully evaluated the MOLGENIS toolkit for the rapid prototyping of many types of biomedical applications, including next-generation sequencing, GWAS, QTL, proteomics and biobanking. Writing 500 lines of model XML typically replaces 15,000 lines of hand-written programming code, which allows for quick adaptation if the information system is not yet to the biologist’s satisfaction. Each application generated with MOLGENIS comes with an optimized database back-end, user interfaces for biologists to manage and exploit their data, programming interfaces for bioinformaticians to script analysis tools in R, Java, SOAP, REST/JSON and RDF, a tab-delimited file format to ease upload and exchange of data, and detailed technical documentation. Existing databases can be quickly enhanced with MOLGENIS generated interfaces using the ‘ExtractModel’ procedure. Conclusions The MOLGENIS toolkit provides bioinformaticians with a simple model to quickly generate flexible web platforms for all possible genomic, molecular and phenotypic experiments with a richness of interfaces not provided by other tools. All the software and manuals are available free as LGPLv3 open source at http://www.molgenis.org. PMID:21210979
How to Achieve Competence in English: A Quick Reference Handbook.
ERIC Educational Resources Information Center
Johnson, Eric W.
Written to provide a quick, simple, practical reference, this handbook contains explanations and examples of the use of English. Entries, arranged alphabetically, may be as specific as "bibliography,""colons,""dashes,""footnotes," and "prefixes" or as general as articles on cliches, books, figurative language, frame tests, grammar, and plagiarism.…
Ferrer-Aguirre, Alejandra; Romero-González, Roberto; Vidal, J L Martínez; Frenich, Antonia Garrido
2016-05-13
A simple and quick analytical method has been developed for the determination of pharmaceutical compounds in water. An on-line solid-phase extraction (SPE) coupled to liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been optimized to determine 7 contaminants of emerging concern in environmental waters at ngL(-1) levels. This procedure requires minimal sample handling and small sample volume (900μL) with a total running time of 18min. Several SPE parameters were evaluated and optimized in order to achieve a high sample throughput. Therefore sample volume, carryover and reusability of the cartridges were evaluated. Performance characteristics were evaluated and good linearity was obtained (R(2)>0.98). Recoveries were evaluated in spiked samples at three concentrations and the values ranged from 71 to 104%. Intra and inter-day precision was lower than 10 and 13% respectively. Limits of quantification were equal to or lower than 10ngL(-1), except for 1,7-dimethylxanthine (20ngL(-1)) and ibuprofen (50ngL(-1)). The method was applied to 20 environmental water samples, and ibuprofen was the compound most widely detected at concentrations up to 42.06μgL(-1), whereas the other compounds were detected in fewer samples at lower concentrations (up to 15.99μgL(-1)). Copyright © 2016 Elsevier B.V. All rights reserved.
Barker, Charles E.; Dallegge, Todd A.; Clark, Arthur C.
2002-01-01
We have updated a simple polyvinyl chloride plastic canister design by adding internal headspace temperature measurement, and redesigned it so it is made with mostly off-the-shelf components for ease of construction. Using self-closing quick connects, this basic canister is mated to a zero-head manometer to make a simple coalbed methane desorption system that is easily transported in small aircraft to remote localities. This equipment is used to gather timed measurements of pressure, volume and temperature data that are corrected to standard pressure and temperature (STP) and graphically analyzed using an Excel(tm)-based spreadsheet. Used together these elements form an effective, practical canister desorption method.
NASA Technical Reports Server (NTRS)
Emrich, Bill
2006-01-01
A simple method of estimating vehicle parameters appropriate for interplanetary travel can provide a useful tool for evaluating the suitability of particular propulsion systems to various space missions. Although detailed mission analyses for interplanetary travel can be quite complex, it is possible to derive hirly simple correlations which will provide reasonable trip time estimates to the planets. In the present work, it is assumed that a constant thrust propulsion system propels a spacecraft on a round trip mission having equidistant outbound and inbound legs in which the spacecraft accelerates during the first portion of each leg of the journey and decelerates during the last portion of each leg of the journey. Comparisons are made with numerical calculations from low thrust trajectory codes to estimate the range of applicability of the simplified correlations.
A Simple Analytic Model for Estimating Mars Ascent Vehicle Mass and Performance
NASA Technical Reports Server (NTRS)
Woolley, Ryan C.
2014-01-01
The Mars Ascent Vehicle (MAV) is a crucial component in any sample return campaign. In this paper we present a universal model for a two-stage MAV along with the analytic equations and simple parametric relationships necessary to quickly estimate MAV mass and performance. Ascent trajectories can be modeled as two-burn transfers from the surface with appropriate loss estimations for finite burns, steering, and drag. Minimizing lift-off mass is achieved by balancing optimized staging and an optimized path-to-orbit. This model allows designers to quickly find optimized solutions and to see the effects of design choices.
Solvent-Ion Interactions in Salt Water: A Simple Experiment.
ERIC Educational Resources Information Center
Willey, Joan D.
1984-01-01
Describes a procedurally quick, simple, and inexpensive experiment which illustrates the magnitude and some effects of solvent-ion interactions in aqueous solutions. Theoretical information, procedures, and examples of temperature, volume and hydration number calculations are provided. (JN)
2006-10-01
local metal- induced toxicity daily for two weeks following surgery and weekly thereafter for the duration of the study. Task 1 - Determine whether...A quick and simple method for the quantitation of lactate dehydrogenase release in measurements of cellular cytotoxicity and tumor necrosis factor...4 months, no signs of local or systemic toxic- ity were observed (Peuster et al. 2003). Studies on health effects of Ni and Co are more numerous
NASA Astrophysics Data System (ADS)
Li, Li-Na; Ma, Chang-Ming; Chang, Ming; Zhang, Ren-Cheng
2017-12-01
A novel method based on SIMPLe-to-use Interactive Self-modeling Mixture Analysis (SIMPLISMA) and Kernel Partial Least Square (KPLS), named as SIMPLISMA-KPLS, is proposed in this paper for selection of outlier samples and informative samples simultaneously. It is a quick algorithm used to model standardization (or named as model transfer) in near infrared (NIR) spectroscopy. The NIR experiment data of the corn for analysis of the protein content is introduced to evaluate the proposed method. Piecewise direct standardization (PDS) is employed in model transfer. And the comparison of SIMPLISMA-PDS-KPLS and KS-PDS-KPLS is given in this research by discussion of the prediction accuracy of protein content and calculation speed of each algorithm. The conclusions include that SIMPLISMA-KPLS can be utilized as an alternative sample selection method for model transfer. Although it has similar accuracy to Kennard-Stone (KS), it is different from KS as it employs concentration information in selection program. This means that it ensures analyte information is involved in analysis, and the spectra (X) of the selected samples is interrelated with concentration (y). And it can be used for outlier sample elimination simultaneously by validation of calibration. According to the statistical data results of running time, it is clear that the sample selection process is more rapid when using KPLS. The quick algorithm of SIMPLISMA-KPLS is beneficial to improve the speed of online measurement using NIR spectroscopy.
Rapid Identification of Synthetic Cannabinoids in Herbal Incenses with DART-MS and NMR.
Marino, Michael A; Voyer, Brandy; Cody, Robert B; Dane, A John; Veltri, Mercurio; Huang, Ling
2016-01-01
The usage of herbal incenses containing synthetic cannabinoids has caused an increase in medical incidents and triggered legislations to ban these products throughout the world. Law enforcement agencies are experiencing sample backlogs due to the variety of the products and the addition of new and still-legal compounds. In our study, proton nuclear magnetic resonance (NMR) spectroscopy was employed to promptly screen the synthetic cannabinoids after their rapid, direct detection on the herbs and in the powders by direct analysis in real time mass spectrometry (DART-MS). A simple sample preparation protocol was employed on 50 mg of herbal sample matrices for quick NMR detection. Ten synthetic cannabinoids were discovered in fifteen herbal incenses. The combined DART-MS and NMR methods can be used to quickly screen synthetic cannabinoids in powder and herbal samples, serving as a complementary approach to conventional GC-MS or LC-MS methods. © 2015 American Academy of Forensic Sciences.
Optical contrast for identifying the thickness of two-dimensional materials
NASA Astrophysics Data System (ADS)
Bing, Dan; Wang, Yingying; Bai, Jing; Du, Ruxia; Wu, Guoqing; Liu, Liyan
2018-01-01
One of the most intriguing properties of two-dimensional (2D) materials is their thickness dependent properties. A quick and precise technique to identify the layer number of 2D materials is therefore highly desirable. In this review, we will introduce the basic principle of using optical contrast to determine the thickness of 2D material and also its advantage as compared to other modern techniques. Different 2D materials, including graphene, graphene oxide, transitional metal dichalcogenides, black phosphorus, boron nitride, have been used as examples to demonstrate the capability of optical contrast methods. A simple and more efficient optical contrast image technique is also emphasized, which is suitable for quick and large-scale thickness identification. We have also discussed the factors that could affect the experimental results of optical contrast, including incident light angle, anisotropic nature of materials, and also the twisted angle between 2D layers. Finally, we give perspectives on future development of optical contrast methods for the study and application of 2D materials.
Skov, Birgit Guldhammer; Kiss, Katalin; Ramsted, Julie; Linnemann, Dorte
2009-04-25
Cytologic examination of fine-needle aspiration (FNA) material is being used increasingly for the diagnosis of pulmonary lesions. Accurate distinction between nonsmall cell lung cancer (NSCLC), including subgroups, and small cell lung cancer and between primary lung cancer and metastases has therapeutic impact. However, the distinction between these groups may be difficult on smears. In this report, the authors describe a simple method, called cytoscrape (CS), which can be used on virtually any smear to produce material useful for ancillary methods, including immunohistochemistry. Aspirates from 47 patients who had possible malignant infiltrates identified on computed tomography scans of the chest were included. Smears were stained by May-Grunwald-Giemsa and Diff-Quick for diagnostic purposes. CS material was obtained by gently scraping cells off the slides. Clots were made, and the sections were stained for thyroid transcription factor-1 (TTF-1) and mucin. The utility of the CS technique was evaluated by assessing the sensitivity and specificity of the method and by quantifying the extra diagnostic information obtained by the method relative to smears alone. Malignant tumor cells in the CS material were identified in 43 aspirates (91%). Both the sensitivity and the specificity for TTF-1 were 100%. The sensitivity for mucin was 60%, and the specificity for mucin was 100%. The diagnoses made on smears were improved by CS in 31 patients (72%), in that more precise separation of subgroups of NSCLC was possible or information on primary tumors was obtained. The CS technique improved the diagnostic information from FNA in a clinically relevant way. The method is simple, quick, and inexpensive. (c) 2009 American Cancer Society.
Microscale Organic Laboratory: IV. A Simple and Rapid Procedure for Carrying Out Wittig Reactions.
ERIC Educational Resources Information Center
Pike, R. M.; And Others
1986-01-01
Describes two examples where synthetic salt-base mixtures are used in a microscale organic laboratory program as a simple and quick procedure for carrying out Wittig reactions. Both experimental procedures are outlined and discussed. (TW)
NASA Astrophysics Data System (ADS)
McGillivray, Max Falkenberg; Cheng, William; Peters, Nicholas S.; Christensen, Kim
2018-04-01
Mapping resolution has recently been identified as a key limitation in successfully locating the drivers of atrial fibrillation (AF). Using a simple cellular automata model of AF, we demonstrate a method by which re-entrant drivers can be located quickly and accurately using a collection of indirect electrogram measurements. The method proposed employs simple, out-of-the-box machine learning algorithms to correlate characteristic electrogram gradients with the displacement of an electrogram recording from a re-entrant driver. Such a method is less sensitive to local fluctuations in electrical activity. As a result, the method successfully locates 95.4% of drivers in tissues containing a single driver, and 95.1% (92.6%) for the first (second) driver in tissues containing two drivers of AF. Additionally, we demonstrate how the technique can be applied to tissues with an arbitrary number of drivers. In its current form, the techniques presented are not refined enough for a clinical setting. However, the methods proposed offer a promising path for future investigations aimed at improving targeted ablation for AF.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saotome, Naoya, E-mail: naosao@nirs.go.jp; Furukawa, Takuji; Hara, Yousuke
Purpose: Three-dimensional irradiation with a scanned carbon-ion beam has been performed from 2011 at the authors’ facility. The authors have developed the rotating-gantry equipped with the scanning irradiation system. The number of combinations of beam properties to measure for the commissioning is more than 7200, i.e., 201 energy steps, 3 intensities, and 12 gantry angles. To compress the commissioning time, quick and simple range verification system is required. In this work, the authors develop a quick range verification system using scintillator and charge-coupled device (CCD) camera and estimate the accuracy of the range verification. Methods: A cylindrical plastic scintillator blockmore » and a CCD camera were installed on the black box. The optical spatial resolution of the system is 0.2 mm/pixel. The camera control system was connected and communicates with the measurement system that is part of the scanning system. The range was determined by image processing. Reference range for each energy beam was determined by a difference of Gaussian (DOG) method and the 80% of distal dose of the depth-dose distribution that were measured by a large parallel-plate ionization chamber. The authors compared a threshold method and a DOG method. Results: The authors found that the edge detection method (i.e., the DOG method) is best for the range detection. The accuracy of range detection using this system is within 0.2 mm, and the reproducibility of the same energy measurement is within 0.1 mm without setup error. Conclusions: The results of this study demonstrate that the authors’ range check system is capable of quick and easy range verification with sufficient accuracy.« less
Development and evaluation of the quick anaero-system-a new disposable anaerobic culture system.
Yang, Nam Woong; Kim, Jin Man; Choi, Gwang Ju; Jang, Sook Jin
2010-04-01
We developed a new disposable anaerobic culture system, namely, the Quick anaero-system, for easy culturing of obligate anaerobes. Our system consists of 3 components: 1) new disposable anaerobic gas pack, 2) disposable culture-envelope and sealer, and 3) reusable stainless plate rack with mesh containing 10 g of palladium catalyst pellets. To evaluate the efficiency of our system, we used 12 anaerobic bacteria. We prepared 2 sets of ten-fold serial dilutions of the 12 anaerobes, and inoculated these samples on Luria-Bertani (LB) broth and LB blood agar plate (LB-BAP) (BD Diagnostic Systems, USA). Each set was incubated in the Quick anaero-system (DAS Tech, Korea) and BBL GasPak jar with BD GasPak EZ Anaerobe Container System (BD Diagnostic Systems) at 35-37 degrees C for 48 hr. The minimal inoculum size showing visible growth of 12 anaerobes when incubated in both the systems was compared. The minimal inoculum size showing visible growth for 2 out of the 12 anaerobes in the LB broth and 9 out of the 12 anaerobes on LB-BAP was lower for the Quick anaero-system than in the BD GasPak EZ Anaerobe Container System. The mean time (+/-SD) required to achieve absolute anaerobic conditions of the Quick anaero-system was 17 min and 56 sec (+/-3 min and 25 sec). The Quick anaero-system is a simple and effective method of culturing obligate anaerobes, and its performance is superior to that of the BD GasPak EZ Anaerobe Container System.
Self-Alining Quick-Connect Joint
NASA Technical Reports Server (NTRS)
Lucy, M. H.
1983-01-01
Quick connect tapered joint used with minimum manipulation and force. Split ring retainer holds locking ring in place. Minimal force required to position male in female joint, at which time split-ring retainers are triggered to release split locking rings. Originally developed to assemble large space structures, joint is simple, compact, strong, lightweight, self alining, and has no loose parts.
ERIC Educational Resources Information Center
Ram, Ram N.; And Others
1983-01-01
Converting carboxylic acids into their anilides, which usually involves preparation of acid chloride or mixed anhydride followed by treatment with aniline, is tedious and/or time-consuming. A quick and easier procedure, using phenyl isothiocyanate, is provided. Reactions involved and a summary table of results are included. (JN)
Chemical Composition Analysis of Extracts from Ficus Hirta Using Supercritical Fluid
NASA Astrophysics Data System (ADS)
Deng, S. B.; Chen, J. P.; Chen, Y. Z.; Yu, C. Q.; Yang, Y.; Wu, S. H.; Chen, C. Z.
2018-05-01
Ficus hirta was extracted by supercritical carbon dioxide. The volatile chemical components of extracts were analyzed using gas chromatography-mass spectrometry (GC-MS). The percentage of products extracted by Supercritical Fluid Extraction(SFE) was 2.5%. Nineteen volatile compounds were identified. The main volatile components were Elemicin, Psoralen, Palmitic acid, Bergapten, α-Linolenic acid, Medicarpin, Retinoic Acid, Maackiain, and Squalene. The method is simple and quick, and can be used for the preliminary analysis of chemical constituents of supercritical extracts of Ficus hirta.
A simple technique to increase profits in wood products marketing
George B. Harpole
1971-01-01
Mathematical models can be used to solve quickly some simple day-to-day marketing problems. This note explains how a sawmill production manager, who has an essentially fixed-capacity mill, can solve several optimization problems by using pencil and paper, a forecast of market prices, and a simple algorithm. One such problem is to maximize profits in an operating period...
The MOLGENIS toolkit: rapid prototyping of biosoftware at the push of a button.
Swertz, Morris A; Dijkstra, Martijn; Adamusiak, Tomasz; van der Velde, Joeri K; Kanterakis, Alexandros; Roos, Erik T; Lops, Joris; Thorisson, Gudmundur A; Arends, Danny; Byelas, George; Muilu, Juha; Brookes, Anthony J; de Brock, Engbert O; Jansen, Ritsert C; Parkinson, Helen
2010-12-21
There is a huge demand on bioinformaticians to provide their biologists with user friendly and scalable software infrastructures to capture, exchange, and exploit the unprecedented amounts of new *omics data. We here present MOLGENIS, a generic, open source, software toolkit to quickly produce the bespoke MOLecular GENetics Information Systems needed. The MOLGENIS toolkit provides bioinformaticians with a simple language to model biological data structures and user interfaces. At the push of a button, MOLGENIS' generator suite automatically translates these models into a feature-rich, ready-to-use web application including database, user interfaces, exchange formats, and scriptable interfaces. Each generator is a template of SQL, JAVA, R, or HTML code that would require much effort to write by hand. This 'model-driven' method ensures reuse of best practices and improves quality because the modeling language and generators are shared between all MOLGENIS applications, so that errors are found quickly and improvements are shared easily by a re-generation. A plug-in mechanism ensures that both the generator suite and generated product can be customized just as much as hand-written software. In recent years we have successfully evaluated the MOLGENIS toolkit for the rapid prototyping of many types of biomedical applications, including next-generation sequencing, GWAS, QTL, proteomics and biobanking. Writing 500 lines of model XML typically replaces 15,000 lines of hand-written programming code, which allows for quick adaptation if the information system is not yet to the biologist's satisfaction. Each application generated with MOLGENIS comes with an optimized database back-end, user interfaces for biologists to manage and exploit their data, programming interfaces for bioinformaticians to script analysis tools in R, Java, SOAP, REST/JSON and RDF, a tab-delimited file format to ease upload and exchange of data, and detailed technical documentation. Existing databases can be quickly enhanced with MOLGENIS generated interfaces using the 'ExtractModel' procedure. The MOLGENIS toolkit provides bioinformaticians with a simple model to quickly generate flexible web platforms for all possible genomic, molecular and phenotypic experiments with a richness of interfaces not provided by other tools. All the software and manuals are available free as LGPLv3 open source at http://www.molgenis.org.
A simple node and conductor data generator for SINDA
NASA Technical Reports Server (NTRS)
Gottula, Ronald R.
1992-01-01
This paper presents a simple, automated method to generate NODE and CONDUCTOR DATA for thermal match modes. The method uses personal computer spreadsheets to create SINDA inputs. It was developed in order to make SINDA modeling less time consuming and serves as an alternative to graphical methods. Anyone having some experience using a personal computer can easily implement this process. The user develops spreadsheets to automatically calculate capacitances and conductances based on material properties and dimensional data. The necessary node and conductor information is then taken from the spreadsheets and automatically arranged into the proper format, ready for insertion directly into the SINDA model. This technique provides a number of benefits to the SINDA user such as a reduction in the number of hand calculations, and an ability to very quickly generate a parametric set of NODE and CONDUCTOR DATA blocks. It also provides advantages over graphical thermal modeling systems by retaining the analyst's complete visibility into the thermal network, and by permitting user comments anywhere within the DATA blocks.
Saotome, Naoya; Furukawa, Takuji; Hara, Yousuke; Mizushima, Kota; Tansho, Ryohei; Saraya, Yuichi; Shirai, Toshiyuki; Noda, Koji
2016-04-01
Three-dimensional irradiation with a scanned carbon-ion beam has been performed from 2011 at the authors' facility. The authors have developed the rotating-gantry equipped with the scanning irradiation system. The number of combinations of beam properties to measure for the commissioning is more than 7200, i.e., 201 energy steps, 3 intensities, and 12 gantry angles. To compress the commissioning time, quick and simple range verification system is required. In this work, the authors develop a quick range verification system using scintillator and charge-coupled device (CCD) camera and estimate the accuracy of the range verification. A cylindrical plastic scintillator block and a CCD camera were installed on the black box. The optical spatial resolution of the system is 0.2 mm/pixel. The camera control system was connected and communicates with the measurement system that is part of the scanning system. The range was determined by image processing. Reference range for each energy beam was determined by a difference of Gaussian (DOG) method and the 80% of distal dose of the depth-dose distribution that were measured by a large parallel-plate ionization chamber. The authors compared a threshold method and a DOG method. The authors found that the edge detection method (i.e., the DOG method) is best for the range detection. The accuracy of range detection using this system is within 0.2 mm, and the reproducibility of the same energy measurement is within 0.1 mm without setup error. The results of this study demonstrate that the authors' range check system is capable of quick and easy range verification with sufficient accuracy.
Instillation and Fixation Methods Useful in Mouse Lung Cancer Research.
Limjunyawong, Nathachit; Mock, Jason; Mitzner, Wayne
2015-08-31
The ability to instill live agents, cells, or chemicals directly into the lung without injuring or killing the mice is an important tool in lung cancer research. Although there are a number of methods that have been published showing how to intubate mice for pulmonary function measurements, none are without potential problems for rapid tracheal instillation in large cohorts of mice. In the present paper, a simple and quick method is described that enables an investigator to carry out such instillations in an efficient manner. The method does not require any special tools or lighting and can be learned with very little practice. It involves anesthetizing a mouse, making a small incision in the neck to visualize the trachea, and then inserting an intravenous catheter directly. The small incision is quickly closed with tissue adhesive, and the mice are allowed to recover. A skilled student or technician can do instillations at an average rate of 2 min/mouse. Once the cancer is established, there is frequently a need for quantitative histologic analysis of the lungs. Traditionally pathologists usually do not bother to standardize lung inflation during fixation, and analyses are often based on a scoring system that can be quite subjective. While this may sometime be sufficiently adequate for gross estimates of the size of a lung tumor, any proper stereological quantification of lung structure or cells requires a reproducible fixation procedure and subsequent lung volume measurement. Here we describe simple reliable procedures for both fixing the lungs under pressure and then accurately measuring the fixed lung volume. The only requirement is a laboratory balance that is accurate over a range of 1 mg-300 g. The procedures presented here thus could greatly improve the ability to create, treat, and analyze lung cancers in mice.
A Simple and Automatic Method for Locating Surgical Guide Hole
NASA Astrophysics Data System (ADS)
Li, Xun; Chen, Ming; Tang, Kai
2017-12-01
Restoration-driven surgical guides are widely used in implant surgery. This study aims to provide a simple and valid method of automatically locating surgical guide hole, which can reduce operator's experiences and improve the design efficiency and quality of surgical guide. Few literatures can be found on this topic and the paper proposed a novel and simple method to solve this problem. In this paper, a local coordinate system for each objective tooth is geometrically constructed in CAD system. This coordinate system well represents dental anatomical features and the center axis of the objective tooth (coincide with the corresponding guide hole axis) can be quickly evaluated in this coordinate system, finishing the location of the guide hole. The proposed method has been verified by comparing two types of benchmarks: manual operation by one skilled doctor with over 15-year experiences (used in most hospitals) and automatic way using one popular commercial package Simplant (used in few hospitals).Both the benchmarks and the proposed method are analyzed in their stress distribution when chewing and biting. The stress distribution is visually shown and plotted as a graph. The results show that the proposed method has much better stress distribution than the manual operation and slightly better than Simplant, which will significantly reduce the risk of cervical margin collapse and extend the wear life of the restoration.
Mizutani, Hitoshi; Akeda, Tomoko; Yamanaka, Kei-Ichi; Isoda, Kenichi; Gabazza, Esteban C
2012-02-01
Tzanck test has been recently re-evaluated as a method for the diagnosis of herpes virus infection. Giemsa staining for the Tzanck test is time-consuming and laborious. There is a need to develop simple and quick staining methods for bedside diagnosis of this disease. We report a single step and quick method for staining herpes giant cells in Tzanck smears using routinely available inks and physiological saline. A keratinocyte cell line (HaCaT) was cultured on a slide glass and stained with various commercially available blue, blue-black and black inks serially diluted with physiological saline. Clinical smear samples from herpes lesions were also stained with these solutions without specific pretreatment. The nuclei of HaCaT were clearly stained showing high contrast with the cytoplasm using 5% Parker-Quink blue-black ink saline solution. Concentration of ink solution higher or lower than 5% resulted in less contrast. Blue or black inks or other manufacturers' inks can also be used, but staining of the cultured keratinocytes was less clear. Smear of clinical samples from herpes lesions were also stained with 5% ink solution. The nuclei of the multinucleated giant cells were clearly stained, and the sample could be immediately used for microscopic examination. One step staining of Tzanck smear using this diluted ink solution is an inexpensive and a convenient bedside diagnostic tool for the dermatologist. © 2011 Japanese Dermatological Association.
"How Science Works" and Data Logging: Eleven Quick Experiments with a Kettle
ERIC Educational Resources Information Center
Walker, Justin
2010-01-01
The benefits of using data logging to teach "how science works" are presented. Pedagogical approaches that take advantage of other school ICT are briefly described. A series of simple, quick experiments are given together with their resulting charts. Examples of the questions that arise from the charts show how the rich data lead to the refinement…
Electrochemical estrogen screen method based on the electrochemical behavior of MCF-7 cells.
Li, Jinlian; Song, Jia; Bi, Sheng; Zhou, Shi; Cui, Jiwen; Liu, Jiguang; Wu, Dongmei
2016-08-05
It was an urgent task to develop quick, cheap and accurate estrogen screen method for evaluating the estrogen effect of the booming chemicals. In this study, the voltammetric behavior between the estrogen-free and normal fragmented MCF-7 cell suspensions were compared, and the electrochemical signal (about 0.68V attributed by xanthine and guanine) of the estrogen-free fragmented MCF-7 cell suspension was obviously lower than that of the normal one. The electrochemistry detection of ex-secretion purines showed that the ability of ex-secretion purines of cells sharp decreased due to the removing of endogenous estrogen. The results indicated that the electrochemical signal of MCF-7 cells was related to the level of intracellular estrogen. When the level of intracellular estrogen was down-regulated, the concentrations of the xanthine and hypoxanthine decreased, which led to the electrochemical signal of MCF-7 cells fall. Based on the electrochemical signal, the electrochemical estrogen screen method was established. The estrogen effect of estradiol, nonylphenol and bisphenol A was evaluated with the electrochemical method, and the result was accordant with that of MTT assay. The electrochemical estrogen screen method was simple, quickly, cheap, objective, and it exploits a new way for the evaluation of estrogenic effects of chemicals. Copyright © 2016. Published by Elsevier B.V.
Gao, Yi Qin
2008-04-07
Here, we introduce a simple self-adaptive computational method to enhance the sampling in energy, configuration, and trajectory spaces. The method makes use of two strategies. It first uses a non-Boltzmann distribution method to enhance the sampling in the phase space, in particular, in the configuration space. The application of this method leads to a broad energy distribution in a large energy range and a quickly converged sampling of molecular configurations. In the second stage of simulations, the configuration space of the system is divided into a number of small regions according to preselected collective coordinates. An enhanced sampling of reactive transition paths is then performed in a self-adaptive fashion to accelerate kinetics calculations.
Helicopter rotor and engine sizing for preliminary performance estimation
NASA Technical Reports Server (NTRS)
Talbot, P. D.; Bowles, J. V.; Lee, H. C.
1986-01-01
Methods are presented for estimating some of the more fundamental design variables of single-rotor helicopters (tip speed, blade area, disk loading, and installed power) based on design requirements (speed, weight, fuselage drag, and design hover ceiling). The well-known constraints of advancing-blade compressibility and retreating-blade stall are incorporated into the estimation process, based on an empirical interpretation of rotor performance data from large-scale wind-tunnel tests. Engine performance data are presented and correlated with a simple model usable for preliminary design. When approximate results are required quickly, these methods may be more convenient to use and provide more insight than large digital computer programs.
Frequency control of wind turbine in power system
NASA Astrophysics Data System (ADS)
Xu, Huawei
2018-06-01
In order to improve the stability of the overall frequency of the power system, automatic power generation control and secondary frequency adjustment were applied. Automatic power generation control was introduced into power generation planning. A dual-fed wind generator power regulation model suitable for secondary frequency regulation was established. The results showed that this method satisfied the basic requirements of frequency regulation control of large-scale wind power access power systems and improved the stability and reliability of power system operation. Therefore, this system frequency control method and strategy is relatively simple. The effect is significant. The system frequency can quickly reach a steady state. It is worth applying and promoting.
Hamed, Ahmed M; Moreno-González, David; Gámiz-Gracia, Laura; García-Campaña, Ana M
2017-01-01
A simple and efficient method for the determination of 28 carbamates in high-fat cheeses is proposed. The methodology is based on a modified quick, easy, cheap, effective, rugged, and safe procedure as sample treatment using a new sorbent (Z-Sep + ) followed by ultra-high performance liquid chromatography with tandem mass spectrometry determination. The method has been validated in different kinds of cheese (Gorgonzola, Roquefort, and Camembert), achieving recoveries of 70-115%, relative standard deviations lower than 13% and limits of quantification lower than 5.4 μg/kg, below the maximum residue levels tolerated for these compounds by the European legislation. The matrix effect was lower than ±30% for all the studied pesticides. The combination of ultra-high performance liquid chromatography and tandem mass spectrometry with this modified quick, easy, cheap, effective, rugged, and safe procedure using Z-Sep + allowed a high sample throughput and an efficient cleaning of extracts for the control of these residues in cheeses with a high fat content. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Computing Mass Properties From AutoCAD
NASA Technical Reports Server (NTRS)
Jones, A.
1990-01-01
Mass properties of structures computed from data in drawings. AutoCAD to Mass Properties (ACTOMP) computer program developed to facilitate quick calculations of mass properties of structures containing many simple elements in such complex configurations as trusses or sheet-metal containers. Mathematically modeled in AutoCAD or compatible computer-aided design (CAD) system in minutes by use of three-dimensional elements. Written in Microsoft Quick-Basic (Version 2.0).
Efficient Levenberg-Marquardt minimization of the maximum likelihood estimator for Poisson deviates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laurence, T; Chromy, B
2009-11-10
Histograms of counted events are Poisson distributed, but are typically fitted without justification using nonlinear least squares fitting. The more appropriate maximum likelihood estimator (MLE) for Poisson distributed data is seldom used. We extend the use of the Levenberg-Marquardt algorithm commonly used for nonlinear least squares minimization for use with the MLE for Poisson distributed data. In so doing, we remove any excuse for not using this more appropriate MLE. We demonstrate the use of the algorithm and the superior performance of the MLE using simulations and experiments in the context of fluorescence lifetime imaging. Scientists commonly form histograms ofmore » counted events from their data, and extract parameters by fitting to a specified model. Assuming that the probability of occurrence for each bin is small, event counts in the histogram bins will be distributed according to the Poisson distribution. We develop here an efficient algorithm for fitting event counting histograms using the maximum likelihood estimator (MLE) for Poisson distributed data, rather than the non-linear least squares measure. This algorithm is a simple extension of the common Levenberg-Marquardt (L-M) algorithm, is simple to implement, quick and robust. Fitting using a least squares measure is most common, but it is the maximum likelihood estimator only for Gaussian-distributed data. Non-linear least squares methods may be applied to event counting histograms in cases where the number of events is very large, so that the Poisson distribution is well approximated by a Gaussian. However, it is not easy to satisfy this criterion in practice - which requires a large number of events. It has been well-known for years that least squares procedures lead to biased results when applied to Poisson-distributed data; a recent paper providing extensive characterization of these biases in exponential fitting is given. The more appropriate measure based on the maximum likelihood estimator (MLE) for the Poisson distribution is also well known, but has not become generally used. This is primarily because, in contrast to non-linear least squares fitting, there has been no quick, robust, and general fitting method. In the field of fluorescence lifetime spectroscopy and imaging, there have been some efforts to use this estimator through minimization routines such as Nelder-Mead optimization, exhaustive line searches, and Gauss-Newton minimization. Minimization based on specific one- or multi-exponential models has been used to obtain quick results, but this procedure does not allow the incorporation of the instrument response, and is not generally applicable to models found in other fields. Methods for using the MLE for Poisson-distributed data have been published by the wider spectroscopic community, including iterative minimization schemes based on Gauss-Newton minimization. The slow acceptance of these procedures for fitting event counting histograms may also be explained by the use of the ubiquitous, fast Levenberg-Marquardt (L-M) fitting procedure for fitting non-linear models using least squares fitting (simple searches obtain {approx}10000 references - this doesn't include those who use it, but don't know they are using it). The benefits of L-M include a seamless transition between Gauss-Newton minimization and downward gradient minimization through the use of a regularization parameter. This transition is desirable because Gauss-Newton methods converge quickly, but only within a limited domain of convergence; on the other hand the downward gradient methods have a much wider domain of convergence, but converge extremely slowly nearer the minimum. L-M has the advantages of both procedures: relative insensitivity to initial parameters and rapid convergence. Scientists, when wanting an answer quickly, will fit data using L-M, get an answer, and move on. Only those that are aware of the bias issues will bother to fit using the more appropriate MLE for Poisson deviates. However, since there is a simple, analytical formula for the appropriate MLE measure for Poisson deviates, it is inexcusable that least squares estimators are used almost exclusively when fitting event counting histograms. There have been ways found to use successive non-linear least squares fitting to obtain similarly unbiased results, but this procedure is justified by simulation, must be re-tested when conditions change significantly, and requires two successive fits. There is a great need for a fitting routine for the MLE estimator for Poisson deviates that has convergence domains and rates comparable to the non-linear least squares L-M fitting. We show in this report that a simple way to achieve that goal is to use the L-M fitting procedure not to minimize the least squares measure, but the MLE for Poisson deviates.« less
Mechanically Assisted Self-Healing of Ultrathin Gold Nanowires.
Wang, Binjun; Han, Ying; Xu, Shang; Qiu, Lu; Ding, Feng; Lou, Jun; Lu, Yang
2018-04-17
As the critical feature sizes of integrated circuits approaching sub-10 nm, ultrathin gold nanowires (diameter <10 nm) have emerged as one of the most promising candidates for next-generation interconnects in nanoelectronics. Also due to their ultrasmall dimensions, however, the structures and morphologies of ultrathin gold nanowires are more prone to be damaged during practical services, for example, Rayleigh instability can significantly alter their morphologies upon Joule heating, hindering their applications as interconnects. Here, it is shown that upon mechanical perturbations, predamaged, nonuniform ultrathin gold nanowires can quickly recover into uniform diameters and restore their smooth surfaces, via a simple mechanically assisted self-healing process. By examining the local self-healing process through in situ high-resolution transmission electron microscopy, the underlying mechanism is believed to be associated with surface atomic diffusion as evidenced by molecular dynamics simulations. In addition, mechanical manipulation can assist the atoms to overcome the diffusion barriers, as suggested by ab initio calculations, to activate more surface adatoms to diffuse and consequently speed up the self-healing process. This result can provide a facile method to repair ultrathin metallic nanowires directly in functional devices, and quickly restore their microstructures and morphologies by simple global mechanical perturbations. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Data-driven outbreak forecasting with a simple nonlinear growth model
Lega, Joceline; Brown, Heidi E.
2016-01-01
Recent events have thrown the spotlight on infectious disease outbreak response. We developed a data-driven method, EpiGro, which can be applied to cumulative case reports to estimate the order of magnitude of the duration, peak and ultimate size of an ongoing outbreak. It is based on a surprisingly simple mathematical property of many epidemiological data sets, does not require knowledge or estimation of disease transmission parameters, is robust to noise and to small data sets, and runs quickly due to its mathematical simplicity. Using data from historic and ongoing epidemics, we present the model. We also provide modeling considerations that justify this approach and discuss its limitations. In the absence of other information or in conjunction with other models, EpiGro may be useful to public health responders. PMID:27770752
Niu, Renjie; Fu, Chenyu; Xu, Zhiyong; Huang, Jianyuan
2016-04-29
Doctors who practice Traditional Chinese Medicine (TCM) diagnose using four methods - inspection, auscultation and olfaction, interrogation, and pulse feeling/palpation. The shape and shape changes of the moon marks on the nails are an important indication when judging the patient's health. There are a series of classical and experimental theories about moon marks in TCM, which does not have support from statistical data. To verify some experiential theories on moon mark in TCM by automatic data-processing equipment. This paper proposes the equipment that utilizes image processing technology to collect moon mark data of different target groups conveniently and quickly, building a database that combines this information with that gathered from the health and mental status questionnaire in each test. This equipment has a simple design, a low cost, and an optimized algorithm. The practice has been proven to quickly complete automatic acquisition and preservation of key data about moon marks. In the future, some conclusions will likely be obtained from these data; some changes of moon marks related to a special pathological change will be established with statistical methods.
Quick clay and landslides of clayey soils.
Khaldoun, Asmae; Moller, Peder; Fall, Abdoulaye; Wegdam, Gerard; De Leeuw, Bert; Méheust, Yves; Otto Fossum, Jon; Bonn, Daniel
2009-10-30
We study the rheology of quick clay, an unstable soil responsible for many landslides. We show that above a critical stress the material starts flowing abruptly with a very large viscosity decrease caused by the flow. This leads to avalanche behavior that accounts for the instability of quick clay soils. Reproducing landslides on a small scale in the laboratory shows that an additional factor that determines the violence of the slides is the inhomogeneity of the flow. We propose a simple yield stress model capable of reproducing the laboratory landslide data, allowing us to relate landslides to the measured rheology.
Quick Clay and Landslides of Clayey Soils
NASA Astrophysics Data System (ADS)
Khaldoun, Asmae; Moller, Peder; Fall, Abdoulaye; Wegdam, Gerard; de Leeuw, Bert; Méheust, Yves; Otto Fossum, Jon; Bonn, Daniel
2009-10-01
We study the rheology of quick clay, an unstable soil responsible for many landslides. We show that above a critical stress the material starts flowing abruptly with a very large viscosity decrease caused by the flow. This leads to avalanche behavior that accounts for the instability of quick clay soils. Reproducing landslides on a small scale in the laboratory shows that an additional factor that determines the violence of the slides is the inhomogeneity of the flow. We propose a simple yield stress model capable of reproducing the laboratory landslide data, allowing us to relate landslides to the measured rheology.
Qian, Song S; Lyons, Regan E
2006-10-01
We present a Bayesian approach for characterizing background contaminant concentration distributions using data from sites that may have been contaminated. Our method, focused on estimation, resolves several technical problems of the existing methods sanctioned by the U.S. Environmental Protection Agency (USEPA) (a hypothesis testing based method), resulting in a simple and quick procedure for estimating background contaminant concentrations. The proposed Bayesian method is applied to two data sets from a federal facility regulated under the Resource Conservation and Restoration Act. The results are compared to background distributions identified using existing methods recommended by the USEPA. The two data sets represent low and moderate levels of censorship in the data. Although an unbiased estimator is elusive, we show that the proposed Bayesian estimation method will have a smaller bias than the EPA recommended method.
Novel shape memory alloy optical fibre connection method
NASA Astrophysics Data System (ADS)
Trouillard, G.; Zivojinovic, P.; Cerutti, R.; Godmaire, X. Pruneau; Weynant, E.
2010-02-01
In this paper, the capacity and quality of a shape memory alloy device is demonstrated for installation and connection of 125-μm to 1000-μm optical fibres. The new mechanical splice has the particularity of using a very simple tool for aligning and holding the cladding of fibres itself without the need of glue. Optimend main characteristics are its small dimensions (few millimetres), reusability, glueless, ruggedness, low temperature variation, heat dissipation and ease of use. These properties are very suitable for many optical fibre applications where both quick and reliable connections are desirable.
The Voronoi volume and molecular representation of molar volume: equilibrium simple fluids.
Hunjan, Jagtar Singh; Eu, Byung Chan
2010-04-07
The Voronoi volume of simple fluids was previously made use of in connection with volume transport phenomena in nonequilibrium simple fluids. To investigate volume transport phenomena, it is important to develop a method to compute the Voronoi volume of fluids in nonequilibrium. In this work, as a first step to this goal, we investigate the equilibrium limit of the nonequilibrium Voronoi volume together with its attendant related molar (molal) and specific volumes. It is proved that the equilibrium Voronoi volume is equivalent to the molar (molal) volume. The latter, in turn, is proved equivalent to the specific volume. This chain of equivalences provides an alternative procedure of computing the equilibrium Voronoi volume from the molar volume/specific volume. We also show approximate methods of computing the Voronoi and molar volumes from the information on the pair correlation function. These methods may be employed for their quick estimation, but also provide some aspects of the fluid structure and its relation to the Voronoi volume. The Voronoi volume obtained from computer simulations is fitted to a function of temperature and pressure in the region above the triple point but below the critical point. Since the fitting function is given in terms of reduced variables for the Lennard-Jones (LJ) model and the kindred volumes (i.e., specific and molar volumes) are in essence equivalent to the equation of state, the formula obtained is a reduced equation state for simple fluids obeying the LJ model potential in the range of temperature and pressure examined and hence can be used for other simple fluids.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sorokine, Alexandre
2011-10-01
Simple Ontology Format (SOFT) library and file format specification provides a set of simple tools for developing and maintaining ontologies. The library, implemented as a perl module, supports parsing and verification of the files in SOFt format, operations with ontologies (adding, removing, or filtering of entities), and converting of ontologies into other formats. SOFT allows users to quickly create ontologies using only a basic text editor, verify it, and portray it in a graph layout system using customized styles.
Joy, Abraham; Anim-Danso, Emmanuel; Kohn, Joachim
2009-01-01
Methods for the detection and estimation of diphosgene and triphosgene are described. These compounds are widely used phosgene precursors which produce an intensely colored purple pentamethine oxonol dye when reacted with 1,3-dimethylbarbituric acid (DBA) and pyridine (or a pyridine derivative). Two quantitative methods are described, based on either UV absorbance or fluorescence of the oxonol dye. Detection limits are ~ 4 µmol/L by UV and <0.4 µmol/L by fluorescence. The third method is a test strip for the simple and rapid detection and semi-quantitative estimation of diphosgene and triphosgene, using a filter paper embedded with dimethylbarbituric acid and poly(4-vinylpyridine). Addition of a test solution to the paper causes a color change from white to light blue at low concentrations and to pink at higher concentrations of triphosgene. The test strip is useful for quick on-site detection of triphosgene and diphosgene in reaction mixtures. The test strip is easy to perform and provides clear signal readouts indicative of the presence of phosgene precursors. The utility of this method was demonstrated by the qualitative determination of residual triphosgene during the production of poly(Bisphenol A carbonate). PMID:19782219
Justine, Jean-Lou; Briand, Marine J; Bray, Rodney A
2012-07-01
Many methods have been proposed for collecting and fixing parasites, but most were written before the molecular age, and were intended to be practised by experienced parasitologists in well-equipped laboratories. We describe here a very simple method, illustrated by photographs, for collecting helminths from the digestive tract of vertebrates. It only requires a few plastic vials, some ethanol and a means to heat water. Basically, the method consists of: (a) the extraction of all organs from the abdominal cavity; (b) opening the digestive system longitudinally; (c) agitate gut and contents in a saline solution (i.e. ca. 9% NaCl or 1/4 sea water in tap water); (d) decant in saline as many times as needed to clean contents; (e) immediately fix parasites in near-boiling saline; (f) discard saline and keep specimens in 95% ethanol. Additional information is given for collecting parasites from fish gills with a similar process. The method will collect most helminths (digeneans, larval cestodes, nematodes, acanthocephalans) from the digestive tract, and monogeneans and isopod and copepod crustaceans from fish gills. The specimens will be suitable for both morphological study and DNA sequencing. The method is simple, fast, inexpensive and can be used by untrained personnel, even in the field without electricity and without a binocular microscope. It can also be used by trained parasitologists who need to expedite treatment of abundant samples.
Evaluation of service quality in family planning clinics in Lusaka, Zambia.
Hancock, Nancy L; Vwalika, Bellington; Sitali, Elizabeth Siyama; Mbwili-Muleya, Clara; Chi, Benjamin H; Stuart, Gretchen S
2015-10-01
To determine the quality of contraceptive services in family planning clinics in Lusaka, Zambia, using a standardized approach. We utilized the Quick Investigation of Quality, a cross-sectional survey tool consisting of a facility assessment, client-provider observation and client exit interview, in public-sector family planning clinics. Data were collected on availability of seven contraceptive methods, information given to clients, interpersonal relations between providers and clients, providers' technical competence and mechanisms for continuity and follow-up. Data were collected from five client-provider observations and client exit interviews in each of six public-sector family planning clinics. All clinics had at least two contraceptive methods continuously available for the preceding 6 months. Most providers asked clients about concerns with their contraceptive method (80%) and told clients when to return to the clinic (87%). Most clients reported that the provider advised what to do if a problem develops (93%), described possible side effects (89%), explained how to use the method effectively (85%) and told them when to come for follow-up (83%). Clients were satisfied with services received (93%). This application of the Quick Investigation of Quality showed that the participating family planning clinics in Lusaka, Zambia, were prepared to offer high-quality services with the available commodities and that clients were satisfied with the received services. Despite the subjective client satisfaction, quality improvement efforts are needed to increase contraceptive availability. Although clients perceived the quality of care received to be high, family planning service quality could be improved to continuously offer the full spectrum of contraceptive options. The Quick Investigation of Quality was easily implemented in Lusaka, Zambia, and this simple approach could be utilized in a variety of settings as a modality for quality improvement. Copyright © 2015 Elsevier Inc. All rights reserved.
know Soil Know Life - Getting Kids Excited About Soils
NASA Astrophysics Data System (ADS)
Lindbo, David L.; Robinson, Clay; Kozlowski, Deborah
2014-05-01
In the United States soils are often taught in primary school (grade 3-6) but with little excitement or passion. We have been working with schools and teachers to bring our passion about soils to this audience. The methods and message can be conveyed simply and effectively by engaging the students in a dialog and through kinematic learning. Our approach is to begin with a simple question - what are 4 things we cannot live without. The answer - Air, Water, Sunlight, and Soil. Most students say "food, shelter, clothing, plants, animals etc." so we then explain all of those come from soil. This leads us to a quick "dance" illustrating that without soils we would be 'Hungry. Homeless, and Naked". The results are that students and teachers remember this simple message. From this point it is our hope that students will continue to understand the importance of soils and stop treating soils like dirt. Other simple exercises for this younger audience will also be presented.
Lipid-binding analysis using a fat blot assay.
Munnik, Teun; Wierzchowiecka, Magdalena
2013-01-01
Protein-lipid interactions play an important role in lipid metabolism, membrane trafficking and cell -signaling by regulating protein localization, activation, and function. The Fat Blot assay is a relatively simple and inexpensive method to examine these interactions using nitrocellulose membrane-immobilized lipids. The assay is adapted from the method by Dowler et al. (Sci STKE 129:pl6, 2002) and provides qualitative and quantitative information on the relative affinity with which a protein binds to a particular lipid. To perform a Fat Blot assay, serial dilutions of different phospholipids are spotted onto a nitrocellulose membrane. These membranes are then incubated with a lipid-binding protein possessing a GST (or other epitope) tag. The membranes are washed and the protein, which is bound to the membrane by virtue of its interaction with the lipid's head group, is detected by immunoblotting with an antibody against GST (or other epitope). The procedure only requires a few micrograms of protein and is quick, simple and cheap to perform.
In Search of a Better Bean: A Simple Activity to Introduce Plant Biology
ERIC Educational Resources Information Center
Spaccarotella, Kim; James, Roxie
2014-01-01
Measuring plant stem growth over time is a simple activity commonly used to introduce concepts in growth and development in plant biology (Reid & Pu, 2007). This Quick Fix updates the activity and incorporates a real-world application: students consider possible effects of soil substrate and sunlight conditions on plant growth without needing…
NASA Astrophysics Data System (ADS)
Takahashi, Leo
2011-03-01
The use of animation as a teaching tool has long been of interest to the readers of and contributors to this journal.1-5 While the sophisticated techniques presented in the cited papers are excellent and useful, there is one overlooked technique that may be of interest to the teacher who wants something quick and simple to enhance classroom presentations: PowerPoint animation.
ERIC Educational Resources Information Center
Kuntzleman, Thomas S.; Jacobson, Erik C.
2016-01-01
A very simple protocol for teaching Beer's Law and absorption spectrophotometry using a smart phone is described. Materials commonly found in high school chemistry laboratories or even around the house may be used. Data collection and analysis is quick and easy. Despite the simple nature of the experiment, excellent results can be achieved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
David Fritz, John Floren
2013-08-27
Minimega is a simple emulytics platform for creating testbeds of networked devices. The platform consists of easily deployable tools to facilitate bringing up large networks of virtual machines including Windows, Linux, and Android. Minimega attempts to allow experiments to be brought up quickly with nearly no configuration. Minimega also includes tools for simple cluster management, as well as tools for creating Linux based virtual machine images.
Liu, Shu-Yu; Hu, Chang-Qin
2007-10-17
This study introduces the general method of quantitative nuclear magnetic resonance (qNMR) for the calibration of reference standards of macrolide antibiotics. Several qNMR experimental conditions were optimized including delay, which is an important parameter of quantification. Three kinds of macrolide antibiotics were used to validate the accuracy of the qNMR method by comparison with the results obtained by the high performance liquid chromatography (HPLC) method. The purities of five common reference standards of macrolide antibiotics were measured by the 1H qNMR method and the mass balance method, respectively. The analysis results of the two methods were compared. The qNMR is quick and simple to use. In a new medicine research and development process, qNMR provides a new and reliable method for purity analysis of the reference standard.
Suspension and simple optical characterization of two-dimensional membranes
NASA Astrophysics Data System (ADS)
Northeast, David B.; Knobel, Robert G.
2018-03-01
We report on a method for suspending two-dimensional crystal materials in an electronic circuit using an only photoresists and solvents. Graphene and NbSe2 are suspended tens of nanometers above metal electrodes with clamping diameters of several microns. The optical cavity formed from the membrane/air/metal structures enables a quick method to measure the number of layers and the gap separation using comparisons between the expected colour and optical microscope images. This characterization technique can be used with just an illuminated microscope with a digital camera which makes it adaptable to environments where other means of characterization are not possible, such as inside nitrogen glove boxes used in handling oxygen-sensitive materials.
Prototype design based on NX subdivision modeling application
NASA Astrophysics Data System (ADS)
Zhan, Xianghui; Li, Xiaoda
2018-04-01
Prototype design is an important part of the product design, through a quick and easy way to draw a three-dimensional product prototype. Combined with the actual production, the prototype could be modified several times, resulting in a highly efficient and reasonable design before the formal design. Subdivision modeling is a common method of modeling product prototypes. Through Subdivision modeling, people can in a short time with a simple operation to get the product prototype of the three-dimensional model. This paper discusses the operation method of Subdivision modeling for geometry. Take a vacuum cleaner as an example, the NX Subdivision modeling functions are applied. Finally, the development of Subdivision modeling is forecasted.
NASA Astrophysics Data System (ADS)
Jiang, Chao; Qiao, Mingzhong; Zhu, Peng
2017-12-01
A permanent magnet synchronous motor with radial magnetic circuit and built-in permanent magnet is designed for the electric vehicle. Finite element numerical calculation and experimental measurement are adopted to obtain the direct axis and quadrature axis inductance parameters of the motor which are vital important for the motor control. The calculation method is simple, the measuring principle is clear, the results of numerical calculation and experimental measurement are mutual confirmation. A quick and effective method is provided to obtain the direct axis and quadrature axis inductance parameters of the motor, and then improve the design of motor or adjust the control parameters of the motor controller.
Asthma and Respiratory Foundation NZ adult asthma guidelines: a quick reference guide.
Beasley, Richard; Hancox, Robert J; Harwood, Matire; Perrin, Kyle; Poot, Betty; Pilcher, Janine; Reid, Jim; Talemaitoga, Api; Thayabaran, Darmiga
2016-11-18
The purpose of the Asthma and Respiratory Foundation NZ Adult Asthma Guidelines is to provide simple, practical and evidence-based recommendations for the diagnosis, assessment and management of asthma in adults (aged 16 and over) in a quick reference format. The intended users are health professionals responsible for delivering asthma care in the community and hospital Emergency Department settings, and those responsible for the training of such health professionals.
NASA Astrophysics Data System (ADS)
Sun, Tao; Li, Yang; Niu, Qingfen; Li, Tianduo; Liu, Yan
2018-04-01
A new simple and efficient fluorescent sensor L based on 1,8-diaminonaphthalene Schiff-base for highly sensitive and selective determination of Cu2+ in drink and water has been developed. This Cu2+-selective detection over other tested metal ions displayed an obvious color change from blue to colorless easily detected by naked eye. The detection limit is determined to be as low as 13.2 nM and the response time is very fast within 30 s. The 1:1 binding mechanism was well confirmed by fluorescence measurements, IR analysis and DFT calculations. Importantly, this sensor L was employed for quick detection of Cu2+ in drink and environmental water samples with satisfactory results, providing a simple, rapid, reliable and feasible Cu2+-sensing method.
Modal parameter identification using the log decrement method and band-pass filters
NASA Astrophysics Data System (ADS)
Liao, Yabin; Wells, Valana
2011-10-01
This paper presents a time-domain technique for identifying modal parameters of test specimens based on the log-decrement method. For lightly damped multidegree-of-freedom or continuous systems, the conventional method is usually restricted to identification of fundamental-mode parameters only. Implementation of band-pass filters makes it possible for the proposed technique to extract modal information of higher modes. The method has been applied to a polymethyl methacrylate (PMMA) beam for complex modulus identification in the frequency range 10-1100 Hz. Results compare well with those obtained using the Least Squares method, and with those previously published in literature. Then the accuracy of the proposed method has been further verified by experiments performed on a QuietSteel specimen with very low damping. The method is simple and fast. It can be used for a quick estimation of the modal parameters, or as a complementary approach for validation purposes.
Dyeing Insects for Behavioral Assays: the Mating Behavior of Anesthetized Drosophila
Verspoor, Rudi L.; Heys, Chloe; Price, Thomas A. R.
2015-01-01
Mating experiments using Drosophila have contributed greatly to the understanding of sexual selection and behavior. Experiments often require simple, easy and cheap methods to distinguish between individuals in a trial. A standard technique for this is CO2 anaesthesia and then labelling or wing clipping each fly. However, this is invasive and has been shown to affect behavior. Other techniques have used coloration to identify flies. This article presents a simple and non-invasive method for labelling Drosophila that allows them to be individually identified within experiments, using food coloring. This method is used in trials where two males compete to mate with a female. Dyeing allowed quick and easy identification. There was, however, some difference in the strength of the coloration across the three species tested. Data is presented showing the dye has a lower impact on mating behavior than CO2 in Drosophila melanogaster. The impact of CO2 anaesthesia is shown to depend on the species of Drosophila, with D. pseudoobscura and D. subobscura showing no impact, whereas D. melanogaster males had reduced mating success. The dye method presented is applicable to a wide range of experimental designs. PMID:25938821
Good cash flow = come in fast, go out slow!
Garvey, Sherill
2002-07-01
The formula for successful cash management in home care is a simple one: The agency must bring cash in as quickly as possible, while keeping expenditures at as low and slow a pace as possible. However, while the formula may be simple, success may be elusive unless agency administrators have a well-thought-out plan to handle cash management.
Meloni, Gabriel N; Bertotti, Mauro
2017-01-01
A simple and cost effective alternative for fabricating custom Scanning Electron Microscope (SEM) sample holders using 3D printers and conductive polylactic acid filament is presented. The flexibility of the 3D printing process allowed for the fabrication of sample holders with specific features that enable the high-resolution imaging of nanoelectrodes and nanopipettes. The precise value of the inner semi cone angle of the nanopipettes taper was extracted from the acquired images and used for calculating their radius using electrochemical methods. Because of the low electrical resistivity presented by the 3D printed holder, the imaging of non-conductive nanomaterials, such as alumina powder, was found to be possible. The fabrication time for each sample holder was under 30 minutes and the average cost was less than $0.50 per piece. Despite being quick and economical to fabricate, the sample holders were found to be sufficiently resistant, allowing for multiple uses of the same holder.
Bertotti, Mauro
2017-01-01
A simple and cost effective alternative for fabricating custom Scanning Electron Microscope (SEM) sample holders using 3D printers and conductive polylactic acid filament is presented. The flexibility of the 3D printing process allowed for the fabrication of sample holders with specific features that enable the high-resolution imaging of nanoelectrodes and nanopipettes. The precise value of the inner semi cone angle of the nanopipettes taper was extracted from the acquired images and used for calculating their radius using electrochemical methods. Because of the low electrical resistivity presented by the 3D printed holder, the imaging of non-conductive nanomaterials, such as alumina powder, was found to be possible. The fabrication time for each sample holder was under 30 minutes and the average cost was less than $0.50 per piece. Despite being quick and economical to fabricate, the sample holders were found to be sufficiently resistant, allowing for multiple uses of the same holder. PMID:28753638
Molecular pharming - VLPs made in plants.
Marsian, Johanna; Lomonossoff, George P
2016-02-01
Plant-based expression offers a safe, inexpensive and potentially limitless way to produce therapeutics in a quick and flexible manner. Plants require only simple inorganic nutrients, water, carbon dioxide and sunlight for efficient growth. Virus-like particles (VLPs) are convincing look-alikes of viruses but without carrying infectious genomic material. However, they can still elicit a very potent immune response which makes them ideal vaccine candidates. In this review the different methods of plant expression are described together with the most recent developments in the field of transiently-expressed plant-made VLPs. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Parameswaran, Krishnan R; Rosen, David I; Allen, Mark G; Ganz, Alan M; Risby, Terence H
2009-02-01
Cavity-enhanced tunable diode laser absorption spectroscopy is an attractive method for measuring small concentrations of gaseous species. Ethane is a breath biomarker of lipid peroxidation initiated by reactive oxygen species. A noninvasive means of quickly quantifying oxidative stress status has the potential for broad clinical application. We present a simple, compact system using off-axis integrated cavity output spectroscopy with an interband cascade laser and demonstrate its use in real-time measurements of breath ethane. We demonstrate a detection sensitivity of 0.48 ppb/Hz(1/2).
Complex space monofilar approximation of diffraction currents on a conducting half plane
NASA Technical Reports Server (NTRS)
Lindell, I. V.
1987-01-01
Simple approximation of diffraction surface currents on a conducting half plane, due to an incoming plane wave, is obtained with a line current (monofile) in complex space. When compared to an approximating current at the edge, the diffraction pattern is seen to improve by an order of magnitude for a minimal increase of computation effort. Thus, the inconvient Fresnel integral functions can be avoided for quick calculations of diffracted fields and the accuracy is good in other directions than along the half plane. The method can be applied to general problems involving planar metal edges.
Ouyang, Guiping; Song, Baoan; Zhang, Huiping; Yang, Song; Jin, Linhong; Li, Qianzhu; Hu, Deyu
2005-10-31
A facile synthesis of 3-methylthio-3-arylamino-2-cyanoacrylates from 3,3-dimethylthioacrylate and aromatic amines or amino pyridines has been achieved in moderate to high yields (64.0% ~ 93.5%) in 30 minutes at 50 degrees C under microwave irradiation. This method is very simple and the reaction conditions are mild, environmentally friendly and more importantly, quick. In the 3-(4,5-dimethylthiazol- 2-yl)-2,5-diphenyltetrazolium bromide (MTT) test, some of the title compounds were found to possess good antiproliferation activity towards PC3 cells.
Wang, Yi; Li, Xiaojuan; Liu, Yan-Hui; Richardson, Daisy; Li, Huijuan; Shameem, Mohammed; Yang, Xiaoyu
Monoclonal antibodies are subjected to a wide variety of post-translational modifications (PTMs) that cause structural heterogeneity. Characterization and control of these modifications or quality attributes are critical to ensure antibody quality and to define any potential effects on the ultimate safety and potency of antibody therapeutics. The biopharmaceutical industry currently uses numerous tools to analyze these quality attributes individually, which requires substantial time and resources. Here, we report a simple and ultrafast bottom-up liquid chromatography-mass spectrometry (uLC-MS) method with 5 min tryptic digestion to simultaneously analyze multiple modifications, including oxidation, deamidation, isomerization, glycation, glycosylation, and N-terminal pyro-glutamate formation, which can occur during antibody production in mammalian cell culture, during purification and/or on storage. Compared to commonly used preparation procedures, this uLC-MS method eliminates assay artifacts of falsely-increased Met oxidation, Asp isomerization, and Asn deamidation, a problem associated with long digestion times in conventional LC-MS methods. This simple, low artifact multi-attribute uLC-MS method can be used to quickly and accurately analyze samples at any stage of antibody drug development, in particular for clone and media selection during cell culture development.
NASA Technical Reports Server (NTRS)
Rhodes, David B.; Franke, John M.; Jones, Stephen B.; Leighty, Bradley D.
1992-01-01
Simple light-meter circuit used to position knife edge of schlieren optical system to block exactly half light. Enables operator to check quickly position of knife edge between tunnel runs to ascertain whether or not in alignment. Permanent measuring system made part of each schlieren system. If placed in unused area of image plane, or in monitoring beam from mirror knife edge, provides real-time assessment of alignment of schlieren system.
SPOCS: software for predicting and visualizing orthology/paralogy relationships among genomes.
Curtis, Darren S; Phillips, Aaron R; Callister, Stephen J; Conlan, Sean; McCue, Lee Ann
2013-10-15
At the rate that prokaryotic genomes can now be generated, comparative genomics studies require a flexible method for quickly and accurately predicting orthologs among the rapidly changing set of genomes available. SPOCS implements a graph-based ortholog prediction method to generate a simple tab-delimited table of orthologs and in addition, html files that provide a visualization of the predicted ortholog/paralog relationships to which gene/protein expression metadata may be overlaid. A SPOCS web application is freely available at http://cbb.pnnl.gov/portal/tools/spocs.html. Source code for Linux systems is also freely available under an open source license at http://cbb.pnnl.gov/portal/software/spocs.html; the Boost C++ libraries and BLAST are required.
Design Principles for Rapid Prototyping Forces Sensors using 3D Printing.
Kesner, Samuel B; Howe, Robert D
2011-07-21
Force sensors provide critical information for robot manipulators, manufacturing processes, and haptic interfaces. Commercial force sensors, however, are generally not adapted to specific system requirements, resulting in sensors with excess size, cost, and fragility. To overcome these issues, 3D printers can be used to create components for the quick and inexpensive development of force sensors. Limitations of this rapid prototyping technology, however, require specialized design principles. In this paper, we discuss techniques for rapidly developing simple force sensors, including selecting and attaching metal flexures, using inexpensive and simple displacement transducers, and 3D printing features to aid in assembly. These design methods are illustrated through the design and fabrication of a miniature force sensor for the tip of a robotic catheter system. The resulting force sensor prototype can measure forces with an accuracy of as low as 2% of the 10 N measurement range.
Data-driven outbreak forecasting with a simple nonlinear growth model.
Lega, Joceline; Brown, Heidi E
2016-12-01
Recent events have thrown the spotlight on infectious disease outbreak response. We developed a data-driven method, EpiGro, which can be applied to cumulative case reports to estimate the order of magnitude of the duration, peak and ultimate size of an ongoing outbreak. It is based on a surprisingly simple mathematical property of many epidemiological data sets, does not require knowledge or estimation of disease transmission parameters, is robust to noise and to small data sets, and runs quickly due to its mathematical simplicity. Using data from historic and ongoing epidemics, we present the model. We also provide modeling considerations that justify this approach and discuss its limitations. In the absence of other information or in conjunction with other models, EpiGro may be useful to public health responders. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Asher, Innes; McNamara, David; Davies, Cheryl; Demetriou, Teresa; Fleming, Theresa; Harwood, Matire; Hetaraka-Stevens, Lorraine; Ingham, Tristram; Kristiansen, John; Reid, Jim; Rickard, Debbie; Ryan, Debbie
2017-12-01
The purpose of the New Zealand Child and adolescent asthma guidelines: a quick reference guide is to provide simple, practical, evidence-based recommendations for the diagnosis, assessment and management of asthma in children and adolescents in New Zealand, with the aim of improving outcomes and reducing inequities. The intended users are health professionals responsible for delivering asthma care in the community and hospital emergency department settings, and those responsible for the training of such health professionals.
Radhakumary, C; Sreenivasan, K
2011-07-21
We discuss here a quick, simple, economic and ecofriendly method through a completely green route for the selective detection of Hg(2+) in aqueous samples. Here we exploited the ability of chitosan to generate gold nanoparticles and subsequently to act as a stabilizer for the formed nanoparticles. When chitosan stabilized gold nanoparticles (CH-Au NPs) are interacted with Hg(2+) a blue shift for its localized surface plasmon resonance absorbance (LSPR) band is observed. The blue shift is reasoned to be due to the formation of a thin layer of mercury over gold. A concentration as low as 0.01 ppm to a maximum of 100 ppm Hg(2+) can be detected based on this blue shift of the CH-Au NPs. While all other reported methods demand complex reaction steps and costly chemicals, the method we reported here is a simple, rapid and selective approach for the detection of Hg(2+). Our results also show that the CH-Au NPs have excellent selectivity to Hg(2+) over common cations namely, Pb(2+), Cd(2+), Mn(2+), Fe(2+), Ag(1+), Ce(4+), Ni(2+), and Cu(2+).
Tsai, Chia-Ju; Li, Jih-Heng; Feng, Chia-Hsien
2015-09-04
A novel, simple and quick sample preparation method was developed and used for pre-concentration and extraction of six phenylpropenes, including anethole, estragole, eugenol, methyl eugenol, safrole and myristicin, from oil samples by dual dispersive liquid-liquid microextraction. Gas chromatography-mass spectrometry was used for determination and separation of compounds. Several experimental parameters affecting extraction efficiency were evaluated and optimized, including forward-extractant type and volume, surfactant type and concentration, water volume, and back-extractant type and volume. For all analytes (10-1000ng/mL), the limits of detection (S/N≧3) ranged from 1.0 to 3.0ng/mL; the limits of quantification (S/N≧10) ranged from 2.5 to 10.0ng/mL; and enrichment factors ranged from 3.2 to 37.1 times. Within-run and between-run relative standard deviations (n=6) were less than 2.61% and less than 4.33%, respectively. Linearity was excellent with determination coefficients (r(2)) above 0.9977. The experiments showed that the proposed method is a simple, effective, and environmentally friendly method of analyzing phenylpropenes in oil samples. Copyright © 2015 Elsevier B.V. All rights reserved.
The use of three-dimensional printing to produce in vitro slice chambers
Hyde, James; MacNicol, Melanie; Odle, Angela; Garcia-Rill, Edgar
2014-01-01
Background In recent years, 3D printing technology has become inexpensive and simple enough that any lab can own and use one of these printers. New Method We explored the potential use of 3D printers for quickly and easily producing in vitro slice chambers for patch clamp electrophysiology. Slice chambers were produced using five available plastics: ABS, PLA, Nylon 618, Nylon 680, and T-glase. These “lab-made” chambers were also made using stereolithography through a professional printing service (Shapeways). This study measured intrinsic membrane properties of neurons in the brain stem pedunculopontine nucleus (PPN) and layer V pyramidal neurons in retrosplenial cortex. Results Nylon 680 and T-glase significantly hyperpolarized PPN neurons. ABS increased input resistance, decreased action potential amplitude, and increased firing frequency in pyramidal cortical neurons. To test long term exposure to each plastic, human neuroblastoma SHSY5Y cell cultures were exposed to each plastic for 1 week. ABS decreased cell counts while Nylon 618 and Shapeways plastics eliminated cells. Primary mouse pituitary cultures were also tested for 24-hour exposure. ABS decreased cell counts while Nylon 618 and Shapeways plastics decreased cell counts. Comparison to Existing Methods Chambers can be quickly and inexpensively printed in the lab. ABS, PLA, Nylon 680, and T-glase plastics would suffice for many experiments instead of commercially produced slice chambers. Conclusions While these technologies are still in their infancy, they represent a powerful addition to the lab environment. With careful selection of print material, slice chambers can be quickly and inexpensively manufactured in the lab. PMID:25251556
NASA Astrophysics Data System (ADS)
Lipka, Michał; Parniak, Michał; Wasilewski, Wojciech
2017-09-01
We present an experimental realization of the optical frequency locked loop applied to long-term frequency difference stabilization of broad-line DFB lasers along with a new independent method to characterize relative phase fluctuations of two lasers. The presented design is based on a fast photodiode matched with an integrated phase-frequency detector chip. The locking setup is digitally tunable in real time, insensitive to environmental perturbations and compatible with commercially available laser current control modules. We present a simple model and a quick method to optimize the loop for a given hardware relying exclusively on simple measurements in time domain. Step response of the system as well as phase characteristics closely agree with the theoretical model. Finally, frequency stabilization for offsets within 4-15 GHz working range achieving <0.1 Hz long-term stability of the beat note frequency for 500 s averaging time period is demonstrated. For these measurements we employ an I/Q mixer that allows us to precisely and independently measure the full phase trace of the beat note signal.
The Automatic Recognition of the Abnormal Sky-subtraction Spectra Based on Hadoop
NASA Astrophysics Data System (ADS)
An, An; Pan, Jingchang
2017-10-01
The skylines, superimposing on the target spectrum as a main noise, If the spectrum still contains a large number of high strength skylight residuals after sky-subtraction processing, it will not be conducive to the follow-up analysis of the target spectrum. At the same time, the LAMOST can observe a quantity of spectroscopic data in every night. We need an efficient platform to proceed the recognition of the larger numbers of abnormal sky-subtraction spectra quickly. Hadoop, as a distributed parallel data computing platform, can deal with large amounts of data effectively. In this paper, we conduct the continuum normalization firstly and then a simple and effective method will be presented to automatic recognize the abnormal sky-subtraction spectra based on Hadoop platform. Obtain through the experiment, the Hadoop platform can implement the recognition with more speed and efficiency, and the simple method can recognize the abnormal sky-subtraction spectra and find the abnormal skyline positions of different residual strength effectively, can be applied to the automatic detection of abnormal sky-subtraction of large number of spectra.
A Multipurpose Experiment with an Electronic Balance
ERIC Educational Resources Information Center
Ganci, S.
2008-01-01
This short article describes some useful and quick applications of a cooking electronic balance. Newton's third law, Archimedes buoyancy and an estimate of relative density are accomplished in a very simple way. (Contains 1 figure.)
Note: a simple experimental arrangement to generate optical vortex beams.
Kumar, Dhirendra; Das, Abhijit; Boruah, Bosanta R
2013-02-01
In this Note, we present a simple experimental arrangement to generate optical vortex beams. We have demonstrated how by taking print of an interferogram on a transparent sheet, vortex beams with various topological charges can be generated. Experimental results show that the vortex beam indeed carries the topological charge that is used to compute the interferograms. In addition to being simple and inexpensive, one major advantage of the arrangement is that it makes it possible to generate different vortex beams quickly, unlike using the photographic process to create the holograms.
[Comparison of the quick Gram stain method to the B&M modified and favor methods].
Osawa, Kayo; Kataoka, Nobumasa; Maruo, Toshio
2011-01-01
The Gram stain is an established method for bacterial identification, but the time needed to carry out this stain is 2-3 min. We attempted to shorten this time and stained a total of 70 clinical specimens isolated from using the Bartholomew & Mittwer (B&M) modified or Favor methods with a 3 s duration for washing and staining steps. Results were plotted and analyzed using a Hue Saturation Intensity (HSI) model. The range based on a plot of the two methods with the HSI model was presented as a reference interval. Our results indicated that 100% (35/35) of strains were Gram positive and 97.1% (34/35) were Gram negative for the quick B&M modified method. In the quick Favor method, 80.0% (28/35) were Gram positive and 68.6% (24/35) of strains were Gram negative. We propose that the quick B&M modified method is equivalent to the standard Gram staining method and is superior to the quick Favor method.
dos Santos, W D; Ferrarese, Maria de Lourdes Lucio; Ferrarese-Filho, O
2006-01-01
This study proposes a simple, quick and reliable method for determining the cinnamyl alcohol dehydrogenase (CAD; EC 1.1.1.195) activity in soybean (Glycine max L. Merr.) roots using reversed-phase high performance liquid chromatography (RP-HPLC). The method includes a single extraction of the tissue and conduction of the enzymatic reaction at 30 degrees C with cinnamaldehydes (coniferyl or sinapyl), substrates of CAD. Disappearance of the substrates in the reaction mixture is monitored at 340 nm (for coniferaldehyde) or 345 nm (for sinapaldehyde) by isocratic elution with methanol/acetic acid through a GLC-ODS (M) column. This HPLC technique furnishes a rapid and reliable measure of cinnamaldehyde substrates, and may be used as an alternative tool to analyze CAD activity in enzyme preparation without previous purification.
A Simple Recipe for Whitening Old Newspaper Clippings
NASA Astrophysics Data System (ADS)
Carter, Henry A.
1995-07-01
Newspaper clippings tend to brown quickly with aging as the result of chromophores that form during the degradation of one or more components of paper. Newsprint that consists of approximately 40% lignin is particularly susceptible to browning due to the relative ease of the oxidation of lignin. For readers who wish to experiment with both whitening and deacidifying old newspaper clippings, a simple recipe requiring few materials is presented.
A discerning approach to simple aesthetic orthodontics.
Noar, J H; Sharma, S; Roberts-Harry, D; Qureshi, T
2015-02-16
There is currently considerable interest from general dental practitioners (GDPs) in the use of simple orthodontics to treat adult malocclusions. There is controversy in this, particularly in relation to 'quick fixes', simple orthodontics and 'straight teeth in six months' as opposed to more conventional treatment where the whole malocclusion is treated. This article will present a case for the use of simple aesthetic adult orthodontics in a measured and planned way. It will discuss the processes, planning and the importance of consent. It will also highlight how digital technology is used to preview, consent and execute an aesthetic result. Many of the recent systems emerging, have been as a result of the demand and supply of cosmetic dentistry. This, to a degree, has not helped since the implication of a 'quick-fix' is associated with this field. There has also been discussion on what the limits of GDP orthodontics should be. There is variability in how GDPs approach orthodontics, their experience, skill and ability to treat to an acceptable standard. Short courses may be one way of delivering orthodontic training but some of these courses are not regulated and the amount of internal mentoring is variable. This article highlights some of the systems in use, and potential upsides and downsides of this approach.
A green method of graphene preparation in an alkaline environment.
Štengl, Václav; Henych, Jiří; Bludská, Jana; Ecorchard, Petra; Kormunda, Martin
2015-05-01
We present a new, simple, quick and ecologically friendly method of exfoliating graphite to produce graphene. The method is based on the intercalation of a permanganate M2MnO4 (M=K, Na, Li), which is formed by the reaction of a manganate MMnO4 with an alkali metal hydroxide MOH. The quality of exfoliation and the morphology were determined using X-ray photoelectron spectroscopy, X-ray diffraction and microscopic techniques, including transmission electron microscopy and atomic force microscopy. We observed that a stable graphene suspension could be prepared under strongly alkaline conditions in the presence of permanganate and ultrasound assistance. The use of only an alkaline environment for the direct preparation of graphene from graphite structures has not been previously described or applied. It was found that such a method of preparation leads to surprisingly high yields and a stable product for hydrophilic graphene applications. Copyright © 2014 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Yu; Li, Shunbo; Wen, Weijia, E-mail: phwen@ust.hk
A local area temperature monitor is important for precise control of chemical and biological processes in microfluidics. In this work, we developed a facile method to realize micron spatial resolution of temperature mapping in a microfluidic channel quickly and cost effectively. Based on the temperature dependent fluorescence emission of NaYF{sub 4}:Yb{sup 3+}, Er{sup 3+} upconversion nanoparticles (UCNPs) under near-infrared irradiation, ratio-metric imaging of UCNPs doped polydimethylsiloxane can map detailed temperature distribution in the channel. Unlike some reported strategies that utilize temperature sensitive organic dye (such as Rhodamine) to achieve thermal sensing, our method is highly chemically inert and physically stablemore » without any performance degradation in long term operation. Moreover, this method can be easily scaled up or down, since the spatial and temperature resolution is determined by an optical imaging system. Our method supplied a simple and efficient solution for temperature mapping on a heterogeneous surface where usage of an infrared thermal camera was limited.« less
Lott, B.; Escande, L.; Larsson, S.; ...
2012-07-19
Here, we present a method enabling the creation of constant-uncertainty/constant-significance light curves with the data of the Fermi-Large Area Telescope (LAT). The adaptive-binning method enables more information to be encapsulated within the light curve than with the fixed-binning method. Although primarily developed for blazar studies, it can be applied to any sources. Furthermore, this method allows the starting and ending times of each interval to be calculated in a simple and quick way during a first step. The reported mean flux and spectral index (assuming the spectrum is a power-law distribution) in the interval are calculated via the standard LATmore » analysis during a second step. In the absence of major caveats associated with this method Monte-Carlo simulations have been established. We present the performance of this method in determining duty cycles as well as power-density spectra relative to the traditional fixed-binning method.« less
NASA Astrophysics Data System (ADS)
Floberg, J. M.; Holden, J. E.
2013-02-01
We introduce a method for denoising dynamic PET data, spatio-temporal expectation-maximization (STEM) filtering, that combines four-dimensional Gaussian filtering with EM deconvolution. The initial Gaussian filter suppresses noise at a broad range of spatial and temporal frequencies and EM deconvolution quickly restores the frequencies most important to the signal. We aim to demonstrate that STEM filtering can improve variance in both individual time frames and in parametric images without introducing significant bias. We evaluate STEM filtering with a dynamic phantom study, and with simulated and human dynamic PET studies of a tracer with reversible binding behaviour, [C-11]raclopride, and a tracer with irreversible binding behaviour, [F-18]FDOPA. STEM filtering is compared to a number of established three and four-dimensional denoising methods. STEM filtering provides substantial improvements in variance in both individual time frames and in parametric images generated with a number of kinetic analysis techniques while introducing little bias. STEM filtering does bias early frames, but this does not affect quantitative parameter estimates. STEM filtering is shown to be superior to the other simple denoising methods studied. STEM filtering is a simple and effective denoising method that could be valuable for a wide range of dynamic PET applications.
Chorny, Michael; Levy, Daniel; Schumacher, Ilana; Lichaa, Chaim; Gruzman, Boris; Livshits, Oleg; Lomnicky, Yossi
2003-04-24
Benoxinate is a local anaesthetic used for ophthalmic applications. The aim of this study was to develop a rapid and simple stability-indicating method for the determination of benoxinate formulated for ophthalmic use, evaluate its long-term stability and identify its major degradation product. Benoxinate was eluted on a 10 microm Spherisorb phenyl column, 250 x 3.2 mm, with a mobile phase consisting of acetonitrile-buffer (pH 3.5) (35:65, v/v), pumped at 0.8 ml min(-1) flow rate. The buffer was composed of sodium dihydrogen phosphate (50 mM), sodium hydrogen sulfate (2.5 mM) and 1-heptanesulfonic acid sodium salt (5 mM). The analyte was quantified spectrophotometrically at 308 nm. The chromatograms of benoxinate formulations obtained by this method showed benoxinate (t = 4.5 min) well resolved from its degradation product (t = 2.3 min), which was separately identified by means of HPLC-MS as 4-amino-3-butoxybenzoic acid. The assay was demonstrated to have high accuracy, precision and linearity. The method was implemented in investigating the long-term stability of benoxinate 0.4% ophthalmic solutions. The method was found to be simple, quick and selective in determining benoxinate concentrations in fresh and aged preparations.
Grasp specific and user friendly interface design for myoelectric hand prostheses.
Mohammadi, Alireza; Lavranos, Jim; Howe, Rob; Choong, Peter; Oetomo, Denny
2017-07-01
This paper presents the design and characterisation of a hand prosthesis and its user interface, focusing on performing the most commonly used grasps in activities of daily living (ADLs). Since the operation of a multi-articulated powered hand prosthesis is difficult to learn and master, there is a significant rate of abandonment by amputees in preference for simpler devices. In choosing so, amputees chose to live with fewer features in their prosthesis that would more reliably perform the basic operations. In this paper, we look simultaneously at a hand prosthesis design method that aims for a small number of grasps, a low complexity user interface and an alternative method to the current use of EMG as a preshape selection method through the use of a simple button; to enable amputees to get to and execute the intended hand movements intuitively, quickly and reliably. An experiment is reported at the end of the paper comparing the speed and accuracy with which able-bodied naive subjects are able to select the intended preshapes through the use of a simplified EMG method and a simple button. It is shown that the button was significantly superior in the speed of successful task completion and marginally superior in accuracy (success of first attempt).
An Excel macro for generating trilinear plots.
Shikaze, Steven G; Crowe, Allan S
2007-01-01
This computer note describes a method for creating trilinear plots in Microsoft Excel. Macros have been created in MS Excel's internal language: Visual Basic for Applications (VBA). A simple form has been set up to allow the user to input data from an Excel worksheet. The VBA macro is used to convert the triangular data (which consist of three columns of percentage data) into X-Y data. The macro then generates the axes, labels, and grid for the trilinear plot. The X-Y data are plotted as scatter data in Excel. By providing this macro in Excel, users can create trilinear plots in a quick, inexpensive manner.
The Begg's uprighting spring – Revisited
Kumar, Vinay; Sundareswaran, Shobha
2015-01-01
Uprighting springs, an integral part of the Begg ligsht wire differential force technique is gaining more and more popularity, as a useful adjunct in contemporary preadjusted edgewise appliance systems as well. It can be used with brackets containing vertical slots for mesiodistal crown uprighting, or as braking auxiliaries providing additional anchorage while protracting posteriors. Here, we present a simple and quick chair side method of fabricating and customizing uprighting springs according to the required crown/root movement for correction. This communication would serve as a ready reckoner during fabrication of the springs, thus dispelling the confusion that usually arises regarding direction and position of the coil and active arm. PMID:25657990
NASA Technical Reports Server (NTRS)
Feinberg, L.; Wilson, M.
1993-01-01
To correct for the spherical aberration in the Hubble Space Telescope primary mirror, five anamorphic aspheric mirrors representing correction for three scientific instruments have been fabricated as part of the development of the corrective-optics space telescope axial-replacement instrument (COSTAR). During the acceptance tests of these mirrors at the vendor, a quick and simple method for verifying the asphere surface figure was developed. The technique has been used on three of the aspheres relating to the three instrument prescriptions. Results indicate that the three aspheres are correct to the limited accuracy expected of this test.
Basic Research in the Information Technology Industry
NASA Astrophysics Data System (ADS)
Theis, Thomas N.; Horn, Paul M.
2003-07-01
Why do information technology companies support exploratory research in physics and allied fields? The answer is simple-because of the need to bring new technology quickly to market. Ultimately, even long-term research is all about speed.
A simple apparatus for quick qualitative analysis of CR39 nuclear track detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gautier, D. C.; Kline, J. L.; Flippo, K. A.
2008-10-15
Quantifying the ion pits in Columbia Resin 39 (CR39) nuclear track detector from Thomson parabolas is a time consuming and tedious process using conventional microscope based techniques. A simple inventive apparatus for fast screening and qualitative analysis of CR39 detectors has been developed, enabling efficient selection of data for a more detailed analysis. The system consists simply of a green He-Ne laser and a high-resolution digital single-lens reflex camera. The laser illuminates the edge of the CR39 at grazing incidence and couples into the plastic, acting as a light pipe. Subsequently, the laser illuminates all ion tracks on the surface.more » A high-resolution digital camera is used to photograph the scattered light from the ion tracks, enabling one to quickly determine charge states and energies measured by the Thomson parabola.« less
Human-machine interaction to disambiguate entities in unstructured text and structured datasets
NASA Astrophysics Data System (ADS)
Ward, Kevin; Davenport, Jack
2017-05-01
Creating entity network graphs is a manual, time consuming process for an intelligence analyst. Beyond the traditional big data problems of information overload, individuals are often referred to by multiple names and shifting titles as they advance in their organizations over time which quickly makes simple string or phonetic alignment methods for entities insufficient. Conversely, automated methods for relationship extraction and entity disambiguation typically produce questionable results with no way for users to vet results, correct mistakes or influence the algorithm's future results. We present an entity disambiguation tool, DRADIS, which aims to bridge the gap between human-centric and machinecentric methods. DRADIS automatically extracts entities from multi-source datasets and models them as a complex set of attributes and relationships. Entities are disambiguated across the corpus using a hierarchical model executed in Spark allowing it to scale to operational sized data. Resolution results are presented to the analyst complete with sourcing information for each mention and relationship allowing analysts to quickly vet the correctness of results as well as correct mistakes. Corrected results are used by the system to refine the underlying model allowing analysts to optimize the general model to better deal with their operational data. Providing analysts with the ability to validate and correct the model to produce a system they can trust enables them to better focus their time on producing higher quality analysis products.
Eom, Taeyong; Cho, Hyun-Deok; Kim, Junghyun; Park, Mihee; An, Jinyoung; Kim, Moosung; Kim, Sheen-Hee; Han, Sang Beom
2017-11-01
A simple and rapid method for the simultaneous determination of 11 mycotoxins - aflatoxins B 1 , B 2 , G 1 and G 2 ; fumonisins B 1 , B 2 and B 3 ; ochratoxin A; zearalenone; deoxynivalenol; and T-2 toxin - in edible oils was established using liquid chromatography tandem mass spectrometry (LC-MS/MS). In this study, QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe), QuEChERS with dispersive liquid-liquid microextraction, and solvent extraction were examined for sample preparation. Among these methods, solvent extraction with a mixture of formic acid/acetonitrile (5/95, v/v) successfully extracted all target mycotoxins. Subsequently, a defatting process using n-hexane was employed to remove the fats present in the edible oil samples. Mass spectrometry was carried out using electrospray ionisation in polarity switching mode with multiple reaction monitoring. The developed LC-MS/MS method was validated by assessing the specificity, linearity, recovery, limit of quantification (LOQ), accuracy and precision with reference to Commission Regulation (EC) 401/2006. Mycotoxin recoveries of 51.6-82.8% were achieved in addition to LOQs ranging from 0.025 ng/g to 1 ng/g. The edible oils proved to be relatively uncomplicated matrices and the developed method was applied to 9 edible oil samples, including soybean oil, corn oil and rice bran oil, to evaluate potential mycotoxin contamination. The levels of detection were significantly lower than the international regulatory standards. Therefore, we expect that our developed method, based on simple, two-step sample preparation process, will be suitable for the large-scale screening of mycotoxin contamination in edible oils.
Shrestha, Rojeet; Miura, Yusuke; Hirano, Ken-Ichi; Chen, Zhen; Okabe, Hiroaki; Chiba, Hitoshi; Hui, Shu-Ping
2018-01-01
Fatty acid (FA) profiling of milk has important applications in human health and nutrition. Conventional methods for the saponification and derivatization of FA are time-consuming and laborious. We aimed to develop a simple, rapid, and economical method for the determination of FA in milk. We applied a beneficial approach of microwave-assisted saponification (MAS) of milk fats and microwave-assisted derivatization (MAD) of FA to its hydrazides, integrated with HPLC-based analysis. The optimal conditions for MAS and MAD were determined. Microwave irradiation significantly reduced the sample preparation time from 80 min in the conventional method to less than 3 min. We used three internal standards for the measurement of short-, medium- and long-chain FA. The proposed method showed satisfactory analytical sensitivity, recovery and reproducibility. There was a significant correlation in the milk FA concentrations between the proposed and conventional methods. Being quick, economic, and convenient, the proposed method for the milk FA measurement can be substitute for the convention method.
Quick-Connect/Disconnect Joint For Truss Structures
NASA Technical Reports Server (NTRS)
Sprague, Benny B.
1991-01-01
Simple connector used for temporary structures and pipes. Truss connector joins and aligns structural members. Consists of two sections, one flanged and other with mating internal groove. When flanged half inserted in groove, moves lever of trigger mechanism upward. Cone then shoots into grooved half. Attached without tools in less than 2 seconds and taken apart just as quickly and easily. Developed for assembling structures in outer space, also useful for temporary terrestrial structures like scaffolds and portable bleachers. With modifications, used to join sections of pipelines carrying liquids or gases.
MR-CDF: Managing multi-resolution scientific data
NASA Technical Reports Server (NTRS)
Salem, Kenneth
1993-01-01
MR-CDF is a system for managing multi-resolution scientific data sets. It is an extension of the popular CDF (Common Data Format) system. MR-CDF provides a simple functional interface to client programs for storage and retrieval of data. Data is stored so that low resolution versions of the data can be provided quickly. Higher resolutions are also available, but not as quickly. By managing data with MR-CDF, an application can be relieved of the low-level details of data management, and can easily trade data resolution for improved access time.
Style grammars for interactive visualization of architecture.
Aliaga, Daniel G; Rosen, Paul A; Bekins, Daniel R
2007-01-01
Interactive visualization of architecture provides a way to quickly visualize existing or novel buildings and structures. Such applications require both fast rendering and an effortless input regimen for creating and changing architecture using high-level editing operations that automatically fill in the necessary details. Procedural modeling and synthesis is a powerful paradigm that yields high data amplification and can be coupled with fast-rendering techniques to quickly generate plausible details of a scene without much or any user interaction. Previously, forward generating procedural methods have been proposed where a procedure is explicitly created to generate particular content. In this paper, we present our work in inverse procedural modeling of buildings and describe how to use an extracted repertoire of building grammars to facilitate the visualization and quick modification of architectural structures and buildings. We demonstrate an interactive application where the user draws simple building blocks and, using our system, can automatically complete the building "in the style of" other buildings using view-dependent texture mapping or nonphotorealistic rendering techniques. Our system supports an arbitrary number of building grammars created from user subdivided building models and captured photographs. Using only edit, copy, and paste metaphors, the entire building styles can be altered and transferred from one building to another in a few operations, enhancing the ability to modify an existing architectural structure or to visualize a novel building in the style of the others.
Unprecedented Cell-Selection Using Ultra-Quick Freezing Combined with Aquaporin Expression
Kato, Yasuhiro; Miyauchi, Takayuki; Abe, Youichiro; Kojić, Dušan; Tanaka, Manami; Chikazawa, Nana; Nakatake, Yuhki; Ko, Shigeru B. H.; Kobayashi, Daisuke; Hazama, Akihiro; Fujiwara, Shoko; Uchida, Tatsuya; Yasui, Masato
2014-01-01
Freezing is usually used for preservation and storage of biological samples; however, this process may have some adverse effects such as cell membrane damage. Aquaporin (AQP), a water channel protein, has been suggested to play some roles for cryopreservation although its molecular mechanism remains unclear. Here we show that membrane damage caused by ultra-quick freezing is rescued by the expression of AQP4. We next examine if the expression of AQP combined with ultra-quick freezing can be used to select cells efficiently under freezing conditions where most cells are died. CHO cells stably expressing AQP4 were exclusively selected from mixed cell cultures. Having identified the increased expression of AQP4 during ES cell differentiation into neuro-ectoderm using bioinformatics, we confirmed the improved survival of differentiated ES cells with AQP4 expression. Finally we show that CHO cells transiently transfected with Endothelin receptor A and Aqp4 were also selected and concentrated by multiple cycles of freezing/thawing, which was confirmed with calcium imaging in response to endothelin. Furthermore, we found that the expression of AQP enables a reduction in the amount of cryoprotectants for freezing, thereby decreasing osmotic stress and cellular toxicity. Taken together, we propose that this simple but efficient and safe method may be applicable to the selection of mammalian cells for applications in regenerative medicine as well as cell-based functional assays or drug screening protocols. PMID:24558371
DOE Office of Scientific and Technical Information (OSTI.GOV)
Igarashi, Noriyuki, E-mail: noriyuki.igarashi@kek.jp; Nitani, Hiroaki; Takeichi, Yasuo
BL-15A is a new x-ray undulator beamline at the Photon Factory. It will be dedicated to two independent research activities, simultaneous XAFS/XRF/XRD experiments, and SAXS/WAXS/GI-SAXS studies. In order to supply a choice of micro-focus, low-divergence and collimated beams, a double surface bimorph mirror was recently developed. To achieve further mirror surface optimization, the pencil beam scanning method was applied for “in-situ” beam inspection and the Inverse Matrix method was used for determination of optimal voltages on the piezoelectric actuators. The corrected beam profiles at every focal spot gave good agreement with the theoretical values and the resultant beam performance ismore » promising for both techniques. Quick and stable switching between highly focused and intense collimated beams was established using this new mirror with the simple motorized stages.« less
An Upgrade Pinning Block: A Mechanical Practical Aid for Fast Labelling of the Insect Specimens.
Ghafouri Moghaddam, Mohammad Hossein; Ghafouri Moghaddam, Mostafa; Rakhshani, Ehsan; Mokhtari, Azizollah
2017-01-01
A new mechanical innovation is described to deal with standard labelling of dried specimens on triangular cards and/or pinned specimens in personal and public collections. It works quickly, precisely, and easily and is very useful for maintaining label uniformity in collections. The tools accurately sets the position of labels in the shortest possible time. This tools has advantages including rapid processing, cost effectiveness, light weight, and high accuracy, compared to conventional methods. It is fully customisable, compact, and does not require specialist equipment to assemble. Conventional methods generally require locating holes on the pinning block surface when labelling with a resulting risk to damage of the specimens. Insects of different orders can be labelled by this simple and effective tool.
An Upgrade Pinning Block: A Mechanical Practical Aid for Fast Labelling of the Insect Specimens
Ghafouri Moghaddam, Mohammad Hossein; Rakhshani, Ehsan; Mokhtari, Azizollah
2017-01-01
Abstract A new mechanical innovation is described to deal with standard labelling of dried specimens on triangular cards and/or pinned specimens in personal and public collections. It works quickly, precisely, and easily and is very useful for maintaining label uniformity in collections. The tools accurately sets the position of labels in the shortest possible time. This tools has advantages including rapid processing, cost effectiveness, light weight, and high accuracy, compared to conventional methods. It is fully customisable, compact, and does not require specialist equipment to assemble. Conventional methods generally require locating holes on the pinning block surface when labelling with a resulting risk to damage of the specimens. Insects of different orders can be labelled by this simple and effective tool. PMID:29104440
Conservative Analytical Collision Probabilities for Orbital Formation Flying
NASA Technical Reports Server (NTRS)
Carpenter, J. Russell
2004-01-01
The literature offers a number of approximations for analytically and/or efficiently computing the probability of collision between two space objects. However, only one of these techniques is a completely analytical approximation that is suitable for use in the preliminary design phase, when it is more important to quickly analyze a large segment of the trade space than it is to precisely compute collision probabilities. Unfortunately, among the types of formations that one might consider, some combine a range of conditions for which this analytical method is less suitable. This work proposes a simple, conservative approximation that produces reasonable upper bounds on the collision probability in such conditions. Although its estimates are much too conservative under other conditions, such conditions are typically well suited for use of the existing method.
Conservative Analytical Collision Probability for Design of Orbital Formations
NASA Technical Reports Server (NTRS)
Carpenter, J. Russell
2004-01-01
The literature offers a number of approximations for analytically and/or efficiently computing the probability of collision between two space objects. However, only one of these techniques is a completely analytical approximation that is suitable for use in the preliminary design phase, when it is more important to quickly analyze a large segment of the trade space than it is to precisely compute collision probabilities. Unfortunately, among the types of formations that one might consider, some combine a range of conditions for which this analytical method is less suitable. This work proposes a simple, conservative approximation that produces reasonable upper bounds on the collision probability in such conditions. Although its estimates are much too conservative under other conditions, such conditions are typically well suited for use of the existing method.
Zhang, Baile; Gao, Lihong; Xie, Yingshuang; Zhou, Wei; Chen, Xiaofeng; Lei, Chunni; Zhang, Huan
2017-07-08
A direct analysis in real time tandem mass spectrometry (DART-MS/MS) method was established for quickly screening five illegally added alkaloids of poppy shell from the hot pot condiment, beef noodle soup and seasoning. The samples were extracted and purified by acetonitrile, and then injected under the conditions of ionization temperature of 300℃, grid electrode voltage of 150 V and sampling rate of 0.8 mm/s using DART in the positive ion mode. The determination was conducted by tandem mass spectrometry in positive ESI mode under multiple reaction monitoring (MRM) mode. The method is simple and rapid, and can meet the requirement of rapid screening and analysis of large quantities of samples.
Lai, Yiu Wai; Krause, Michael; Savan, Alan; Thienhaus, Sigurd; Koukourakis, Nektarios; Hofmann, Martin R; Ludwig, Alfred
2011-10-01
A high-throughput characterization technique based on digital holography for mapping film thickness in thin-film materials libraries was developed. Digital holographic microscopy is used for fully automatic measurements of the thickness of patterned films with nanometer resolution. The method has several significant advantages over conventional stylus profilometry: it is contactless and fast, substrate bending is compensated, and the experimental setup is simple. Patterned films prepared by different combinatorial thin-film approaches were characterized to investigate and demonstrate this method. The results show that this technique is valuable for the quick, reliable and high-throughput determination of the film thickness distribution in combinatorial materials research. Importantly, it can also be applied to thin films that have been structured by shadow masking.
Mosely, Jackie A; Stokes, Peter; Parker, David; Dyer, Philip W; Messinis, Antonis M
2018-02-01
A novel method has been developed that enables chemical compounds to be transferred from an inert atmosphere glove box and into the atmospheric pressure ion source of a mass spectrometer whilst retaining a controlled chemical environment. This innovative method is simple and cheap to implement on some commercially available mass spectrometers. We have termed this approach inert atmospheric pressure solids analysis probe ( iASAP) and demonstrate the benefit of this methodology for two air-/moisture-sensitive chemical compounds whose characterisation by mass spectrometry is now possible and easily achieved. The simplicity of the design means that moving between iASAP and standard ASAP is straightforward and quick, providing a highly flexible platform with rapid sample turnaround.
NASA Astrophysics Data System (ADS)
Themens, David R.; Jayachandran, P. T.; Bilitza, Dieter; Erickson, Philip J.; Häggström, Ingemar; Lyashenko, Mykhaylo V.; Reid, Benjamin; Varney, Roger H.; Pustovalova, Ljubov
2018-02-01
In this study, we present a topside model representation to be used by the Empirical Canadian High Arctic Ionospheric Model (E-CHAIM). In the process of this, we also present a comprehensive evaluation of the NeQuick's, and by extension the International Reference Ionosphere's, topside electron density model for middle and high latitudes in the Northern Hemisphere. Using data gathered from all available incoherent scatter radars, topside sounders, and Global Navigation Satellite System Radio Occultation satellites, we show that the current NeQuick parameterization suboptimally represents the shape of the topside electron density profile at these latitudes and performs poorly in the representation of seasonal and solar cycle variations of the topside scale thickness. Despite this, the simple, one variable, NeQuick model is a powerful tool for modeling the topside ionosphere. By refitting the parameters that define the maximum topside scale thickness and the rate of increase of the scale height within the NeQuick topside model function, r and g, respectively, and refitting the model's parameterization of the scale height at the F region peak, H0, we find considerable improvement in the NeQuick's ability to represent the topside shape and behavior. Building on these results, we present a new topside model extension of the E-CHAIM based on the revised NeQuick function. Overall, root-mean-square errors in topside electron density are improved over the traditional International Reference Ionosphere/NeQuick topside by 31% for a new NeQuick parameterization and by 36% for a newly proposed topside for E-CHAIM.
A Left-Hand Rule for Faraday's Law
ERIC Educational Resources Information Center
Salu, Yehuda
2014-01-01
A left-hand rule for Faraday's law is presented here. This rule provides a simple and quick way of finding directional relationships between variables of Faraday's law without using Lenz's rule.
NASA Astrophysics Data System (ADS)
Anis Atikah, Nurul; Yeng Weng, Leong; Anuar, Adzly; Chien Fat, Chau; Sahari, Khairul Salleh Mohamed; Zainal Abidin, Izham
2017-10-01
Currently, the methods of actuating robotic-based prosthetic limbs are moving away from bulky actuators to more fluid materials such as artificial muscles. The main disadvantages of these artificial muscles are their high cost of manufacturing, low-force generation, cumbersome and complex controls. A recent discovery into using super coiled polymer (SCP) proved to have low manufacturing costs, high force generation, compact and simple controls. Nevertheless, the non-linear controls still exists due to the nature of heat-based actuation, which is hysteresis. This makes position control difficult. Using electrically conductive devices allows for very quick heating, but not quick cooling. This research tries to solve the problem by using peltier devices, which can effectively heat and cool the SCP, hence giving way to a more precise control. The peltier device does not actively introduce more energy to a volume of space, which the coiled heating does; instead, it acts as a heat pump. Experiments were conducted to test the feasibility of using peltier as an actuating method on different diameters of nylon fishing strings. Based on these experiments, the performance characteristics of the strings were plotted, which could be used to control the actuation of the string efficiently in the future.
Wang, Yueliang; Fang, Lingling; Chen, Gaoli; Song, Lei; Deng, Zhaoxiang
2018-02-01
Despite the versatile forms of colloidal aggregates, these spontaneously formed structures are often hard to find a suitable application in nanotechnology and materials science. A determinate reason is the lack of a suitable method to capture the transiently formed and quickly evolving colloidal structures in solution. To address this challenge, a simple but highly efficient strategy is herein reported to capture the dynamic and metastable colloidal assemblies formed in an aqueous or nonaqueous solution. This process takes advantage of a recently developed Ag ion soldering reaction to realize a rapid fixation of as-formed metastable assemblies. This method works efficiently for both solid (3D) nanoparticle aggregates and weakly bonded fractal nanoparticle chains (1D). In both cases, very high capturing speed and close to 100% efficiency are achieved to fully retain a quickly growing structure. The soldered nanochains further enable a fabrication of discrete, uniform, and functionalizable nanoparticle clusters with enriched linear conformation by mechanical shearing, which would otherwise be difficult to make. The captured products are water dispersible and mechanically robust, favoring an exploration of their properties toward possible applications. The work paves a way to previously untouched aspects of colloidal science and thus would create new chances in nanotechnology. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Sambursky, Nicole D.; McLeod, Roger David; Silva, Sandra Helena
2009-05-01
This is a novel method for safely and naturally improving vision. with applications for minority, female, and academic entity, financial advantages. The patented Naturoptic Method is a simple system designed to work quickly, requiring only a minimal number of sessions for improvement. Our mentored and unique activities investigated these claims by implementing the Naturoptic method on ourselves over a period of time. Research was conducted at off campus locations with the inventor of the Naturoptic Method. Initial visual acuity and subsequent progress is self assessed, using standard Snellen Eye Charts. Research is designed to document improvements in vision with successive uses of the Naturoptic Method, as mentored teachers or Awardees of ``The Kaan Balam Matagamon Memorial Award,'' with net earnings shared by the designees, academic entities, the American Indians in Science and Engineering Society, AISES, or charity. The Board requires Awardees, its students, or affiliates, to sign non-disclosure agreements. 185/1526
Heidari, Zahra; Roe, Daniel R; Galindo-Murillo, Rodrigo; Ghasemi, Jahan B; Cheatham, Thomas E
2016-07-25
Long time scale molecular dynamics (MD) simulations of biological systems are becoming increasingly commonplace due to the availability of both large-scale computational resources and significant advances in the underlying simulation methodologies. Therefore, it is useful to investigate and develop data mining and analysis techniques to quickly and efficiently extract the biologically relevant information from the incredible amount of generated data. Wavelet analysis (WA) is a technique that can quickly reveal significant motions during an MD simulation. Here, the application of WA on well-converged long time scale (tens of μs) simulations of a DNA helix is described. We show how WA combined with a simple clustering method can be used to identify both the physical and temporal locations of events with significant motion in MD trajectories. We also show that WA can not only distinguish and quantify the locations and time scales of significant motions, but by changing the maximum time scale of WA a more complete characterization of these motions can be obtained. This allows motions of different time scales to be identified or ignored as desired.
Using dust as probes to determine sheath extent and structure
NASA Astrophysics Data System (ADS)
Douglass, Angela; Land, V.; Qiao, K.; Matthews, L.; Hyde, T.
2016-08-01
Two in situ experimental methods are presented in which dust particles are used to determine the extent of the sheath and gain information about the time-averaged electric force profile within a radio frequency (RF) plasma sheath. These methods are advantageous because they are not only simple and quick to carry out, but they also can be performed using standard dusty plasma experimental equipment. In the first method, dust particles are tracked as they fall through the plasma towards the lower electrode. These trajectories are then used to determine the electric force on the particle as a function of height as well as the extent of the sheath. In the second method, dust particle levitation height is measured across a wide range of RF voltages. Similarities were observed between the two experiments, but in order to understand the underlying physics behind these observations, the same conditions were replicated using a self-consistent fluid model. Through comparison of the fluid model and experimental results, it is shown that the particles exhibiting a levitation height that is independent of RF voltage indicate the sheath edge - the boundary between the quasineutral bulk plasma and the sheath. Therefore, both of these simple and inexpensive, yet effective, methods can be applied across a wide range of experimental parameters in any ground-based RF plasma chamber to gain useful information regarding the sheath, which is needed for interpretation of dusty plasma experiments.
Possible Explanation of the Different Temporal Behaviors of Various Classes of Sunspot Groups
NASA Astrophysics Data System (ADS)
Gao, Peng-Xin; Li, Ke-Jun; Li, Fu-Yu
2017-09-01
In order to investigate the periodicity and long-term trends of various classes of sunspot groups (SGs), we separated SGs into two categories: simple SGs (A/U ≤ 4.5, where A represents the total corrected whole spot area of the group in millionths of the solar hemisphere (msh), and U represents the total corrected umbral area of the group in msh); and complex SGs (A/U > 6.2). Based on the revised version of the Greenwich Photoheliographic Results sunspot catalogue, we investigated the periodic behaviors and long-term trends of simple and complex SGs from 1875 to 1976 using the Hilbert-Huang Transform method, and we confirm that the temporal behaviors of simple and complex SGs are quite different. Our main findings are as follows. i) For simple and complex SGs, the values of the Schwabe cycle wax and wane, following the solar activity cycle. ii) There are significant phase differences (almost antiphase) between the periodicity of 53.50 ± 3.79 years extracted from yearly simple SG numbers and the periodicity of 56.21 ± 2.92 years extracted from yearly complex SG numbers. iii) The adaptive trends of yearly simple and complex SG numbers are also quite different: for simple SGs, the values of the adaptive trend gradually increase during the time period of 1875 - 1949, then they decrease gradually from 1949 to 1976, similar to the rise and the maximum phase of a sine curve; for complex SGs, the values of the adaptive trend first slowly increase and then quickly increase, similar to the minimum and rise phase of a sine curve.
Exploring FlyBase Data Using QuickSearch.
Marygold, Steven J; Antonazzo, Giulia; Attrill, Helen; Costa, Marta; Crosby, Madeline A; Dos Santos, Gilberto; Goodman, Joshua L; Gramates, L Sian; Matthews, Beverley B; Rey, Alix J; Thurmond, Jim
2016-12-08
FlyBase (flybase.org) is the primary online database of genetic, genomic, and functional information about Drosophila species, with a major focus on the model organism Drosophila melanogaster. The long and rich history of Drosophila research, combined with recent surges in genomic-scale and high-throughput technologies, mean that FlyBase now houses a huge quantity of data. Researchers need to be able to rapidly and intuitively query these data, and the QuickSearch tool has been designed to meet these needs. This tool is conveniently located on the FlyBase homepage and is organized into a series of simple tabbed interfaces that cover the major data and annotation classes within the database. This unit describes the functionality of all aspects of the QuickSearch tool. With this knowledge, FlyBase users will be equipped to take full advantage of all QuickSearch features and thereby gain improved access to data relevant to their research. © 2016 by John Wiley & Sons, Inc. Copyright © 2016 John Wiley & Sons, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Huafeng; Colabello, Diane M.; Sklute, Elizabeth C.
The absolute absorption coefficient, α(E), is a critical design parameter for devices using semiconductors for light harvesting associated with renewable energy production, both for classic technologies such as photovoltaics and for emerging technologies such as direct solar fuel production. While α(E) is well-known for many classic simple semiconductors used in photovoltaic applications, the absolute values of α(E) are typically unknown for the complex semiconductors being explored for solar fuel production due to the absence of single crystals or crystalline epitaxial films that are needed for conventional methods of determining α(E). In this work, a simple self-referenced method for estimating bothmore » the refractive indices, n(E), and absolute absorption coefficients, α(E), for loose powder samples using diffuse reflectance data is demonstrated. In this method, the sample refractive index can be deduced by refining n to maximize the agreement between the relative absorption spectrum calculated from bidirectional reflectance data (calculated through a Hapke transform which depends on n) and integrating sphere diffuse reflectance data (calculated through a Kubleka–Munk transform which does not depend on n). This new method can be quickly used to screen the suitability of emerging semiconductor systems for light-harvesting applications. The effectiveness of this approach is tested using the simple classic semiconductors Ge and Fe 2O 3 as well as the complex semiconductors La 2MoO 5 and La 4Mo 2O 11. The method is shown to work well for powders with a narrow size distribution (exemplified by Fe 2O 3) and to be ineffective for semiconductors with a broad size distribution (exemplified by Ge). As such, it provides a means for rapidly estimating the absolute optical properties of complex solids which are only available as loose powders.« less
a Method for the Seamlines Network Automatic Selection Based on Building Vector
NASA Astrophysics Data System (ADS)
Li, P.; Dong, Y.; Hu, Y.; Li, X.; Tan, P.
2018-04-01
In order to improve the efficiency of large scale orthophoto production of city, this paper presents a method for automatic selection of seamlines network in large scale orthophoto based on the buildings' vector. Firstly, a simple model of the building is built by combining building's vector, height and DEM, and the imaging area of the building on single DOM is obtained. Then, the initial Voronoi network of the measurement area is automatically generated based on the positions of the bottom of all images. Finally, the final seamlines network is obtained by optimizing all nodes and seamlines in the network automatically based on the imaging areas of the buildings. The experimental results show that the proposed method can not only get around the building seamlines network quickly, but also remain the Voronoi network' characteristics of projection distortion minimum theory, which can solve the problem of automatic selection of orthophoto seamlines network in image mosaicking effectively.
Analysis of the Capability Portfolio Review (CPR)
2014-06-01
facilitated by the MRM feature. PAT allows the analyst to quickly change how summary depictions are generated. Choices include; simple linear...database with supporting software that documents relationships between warfighting activities, the UJTL, systems, ACTDs, roadmaps, and capability areas. It
NASA Technical Reports Server (NTRS)
Soper, Terry A.
1992-01-01
Proposed lightweight dolly enables operator to cart heavy towbar to remote site over unpaved roads or rough terrain. Acts as simple, lightweight towed vehicle to support rear of towbar. Removed quickly at point of use. Saves labor, and eliminates need for truck and forklift.
Ohshima, Chihiro; Takahashi, Hajime; Phraephaisarn, Chirapiphat; Vesaratchavest, Mongkol; Keeratipibul, Suwimon; Kuda, Takashi; Kimura, Bon
2014-01-01
Listeria monocytogenes is the causative bacteria of listeriosis, which has a higher mortality rate than that of other causes of food poisoning. Listeria spp., of which L. monocytogenes is a member, have been isolated from food and manufacturing environments. Several methods have been published for identifying Listeria spp.; however, many of the methods cannot identify newly categorized Listeria spp. Additionally, they are often not suitable for the food industry, owing to their complexity, cost, or time consumption. Recently, high-resolution melting analysis (HRMA), which exploits DNA-sequence differences, has received attention as a simple and quick genomic typing method. In the present study, a new method for the simple, rapid, and low-cost identification of Listeria spp. has been presented using the genes rarA and ldh as targets for HRMA. DNA sequences of 9 Listeria species were first compared, and polymorphisms were identified for each species for primer design. Species specificity of each HRM curve pattern was estimated using type strains of all the species. Among the 9 species, 7 were identified by HRMA using rarA gene, including 3 new species. The remaining 2 species were identified by HRMA of ldh gene. The newly developed HRMA method was then used to assess Listeria isolates from the food industry, and the method efficiency was compared to that of identification by 16S rDNA sequence analysis. The 2 methods were in coherence for 92.6% of the samples, demonstrating the high accuracy of HRMA. The time required for identifying Listeria spp. was substantially low, and the process was considerably simplified, providing a useful and precise method for processing multiple samples per day. Our newly developed method for identifying Listeria spp. is highly valuable; its use is not limited to the food industry, and it can be used for the isolates from the natural environment.
Ohshima, Chihiro; Takahashi, Hajime; Phraephaisarn, Chirapiphat; Vesaratchavest, Mongkol; Keeratipibul, Suwimon; Kuda, Takashi; Kimura, Bon
2014-01-01
Listeria monocytogenes is the causative bacteria of listeriosis, which has a higher mortality rate than that of other causes of food poisoning. Listeria spp., of which L. monocytogenes is a member, have been isolated from food and manufacturing environments. Several methods have been published for identifying Listeria spp.; however, many of the methods cannot identify newly categorized Listeria spp. Additionally, they are often not suitable for the food industry, owing to their complexity, cost, or time consumption. Recently, high-resolution melting analysis (HRMA), which exploits DNA-sequence differences, has received attention as a simple and quick genomic typing method. In the present study, a new method for the simple, rapid, and low-cost identification of Listeria spp. has been presented using the genes rarA and ldh as targets for HRMA. DNA sequences of 9 Listeria species were first compared, and polymorphisms were identified for each species for primer design. Species specificity of each HRM curve pattern was estimated using type strains of all the species. Among the 9 species, 7 were identified by HRMA using rarA gene, including 3 new species. The remaining 2 species were identified by HRMA of ldh gene. The newly developed HRMA method was then used to assess Listeria isolates from the food industry, and the method efficiency was compared to that of identification by 16S rDNA sequence analysis. The 2 methods were in coherence for 92.6% of the samples, demonstrating the high accuracy of HRMA. The time required for identifying Listeria spp. was substantially low, and the process was considerably simplified, providing a useful and precise method for processing multiple samples per day. Our newly developed method for identifying Listeria spp. is highly valuable; its use is not limited to the food industry, and it can be used for the isolates from the natural environment. PMID:24918440
Velázquez, Sergio; Monzó, José M.; Borrachero, María V.; Payá, Jordi
2014-01-01
The pozzolanic activity of the spent catalyst produced by fluid catalytic cracking (FCC) has been studied by various methods in recent years. However, no quick and easy method has been reported for this activity based on the associated studies. In this work, the pozzolanic activity of a spent catalyst was investigated by measuring its electrical conductivity in aqueous suspensions of pozzolan/calcium hydroxide. The behavior of the FCC catalyst residue was compared to that of reactive and inert materials of similar chemical compositions. Further, the influence of temperature on the suspension was studied, and also, a new method was proposed in which the pozzolan/calcium hydroxide ratio was varied (with the initial presence of solid Ca(OH)2 in the system). It was concluded that the method is effective, fast and simple for evaluating the high reactivity of the catalyst. Therefore, this method is an alternative for the evaluation of the reactivity of pozzolanic materials. PMID:28788583
Analytical Assessment for Transient Stability Under Stochastic Continuous Disturbances
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ju, Ping; Li, Hongyu; Gan, Chun
Here, with the growing integration of renewable power generation, plug-in electric vehicles, and other sources of uncertainty, increasing stochastic continuous disturbances are brought to power systems. The impact of stochastic continuous disturbances on power system transient stability attracts significant attention. To address this problem, this paper proposes an analytical assessment method for transient stability of multi-machine power systems under stochastic continuous disturbances. In the proposed method, a probability measure of transient stability is presented and analytically solved by stochastic averaging. Compared with the conventional method (Monte Carlo simulation), the proposed method is many orders of magnitude faster, which makes itmore » very attractive in practice when many plans for transient stability must be compared or when transient stability must be analyzed quickly. Also, it is found that the evolution of system energy over time is almost a simple diffusion process by the proposed method, which explains the impact mechanism of stochastic continuous disturbances on transient stability in theory.« less
NASA Astrophysics Data System (ADS)
Ortega-Martinez, Antonio; Padilla-Martinez, Juan Pablo; Franco, Walfre
2016-04-01
The skin contains several fluorescent molecules or fluorophores that serve as markers of structure, function and composition. UV fluorescence excitation photography is a simple and effective way to image specific intrinsic fluorophores, such as the one ascribed to tryptophan which emits at a wavelength of 345 nm upon excitation at 295 nm, and is a marker of cellular proliferation. Earlier, we built a clinical UV photography system to image cellular proliferation. In some samples, the naturally low intensity of the fluorescence can make it difficult to separate the fluorescence of cells in higher proliferation states from background fluorescence and other imaging artifacts -- like electronic noise. In this work, we describe a statistical image segmentation method to separate the fluorescence of interest. Statistical image segmentation is based on image averaging, background subtraction and pixel statistics. This method allows to better quantify the intensity and surface distributions of fluorescence, which in turn simplify the detection of borders. Using this method we delineated the borders of highly-proliferative skin conditions and diseases, in particular, allergic contact dermatitis, psoriatic lesions and basal cell carcinoma. Segmented images clearly define lesion borders. UV fluorescence excitation photography along with statistical image segmentation may serve as a quick and simple diagnostic tool for clinicians.
NASA Astrophysics Data System (ADS)
Milecki, Andrzej; Pelic, Marcin
2016-10-01
This paper presents results of studies of an application of a new method of piezo bender actuators modelling. A special hysteresis simulation model was developed and is presented. The model is based on a geometrical deformation of main hysteresis loop. The piezoelectric effect is described and the history of the hysteresis modelling is briefly reviewed. Firstly, a simple model for main loop modelling is proposed. Then, a geometrical description of the non-saturated hysteresis is presented and its modelling method is introduced. The modelling makes use of the function describing the geometrical shape of the two hysteresis main curves, which can be defined theoretically or obtained by measurement. These main curves are stored in the memory and transformed geometrically in order to obtain the minor curves. Such model was prepared in the Matlab-Simulink software, but can be easily implemented using any programming language and applied in an on-line controller. In comparison to the other known simulation methods, the one presented in the paper is easy to understand, and uses simple arithmetical equations, allowing to quickly obtain the inversed model of hysteresis. The inversed model was further used for compensation of a non-saturated hysteresis of the piezo bender actuator and results have also been presented in the paper.
Al Asmari, Abdulrahman; Manthiri, Rajamohammed Abbas; Khan, Haseeb Ahmad
2014-11-01
Identification of snake species is important for various reasons including the emergency treatment of snake bite victims. We present a simple method for identification of six snake species using the gel filtration chromatographic profiles of their venoms. The venoms of Echis coloratus, Echis pyramidum, Cerastes gasperettii, Bitis arietans, Naja arabica, and Walterinnesia aegyptia were milked, lyophilized, diluted and centrifuged to separate the mucus from the venom. The clear supernatants were filtered and chromatographed on fast protein liquid chromatography (FPLC). We obtained the 16S rRNA gene sequences of the above species and performed phylogenetic analysis using the neighbor-joining method. The chromatograms of venoms from different snake species showed peculiar patterns based on the number and location of peaks. The dendrograms generated from similarity matrix based on the presence/absence of particular chromatographic peaks clearly differentiated Elapids from Viperids. Molecular cladistics using 16S rRNA gene sequences resulted in jumping clades while separating the members of these two families. These findings suggest that chromatographic profiles of snake venoms may provide a simple and reproducible chemical fingerprinting method for quick identification of snake species. However, the validation of this methodology requires further studies on large number of specimens from within and across species.
Sapozhnikova, Yelena; Simons, Tawana; Lehotay, Steven J
2015-05-13
A simple, fast, and cost-effective sample preparation method, previously developed and validated for the analysis of organic contaminants in fish using low-pressure gas chromatography-tandem mass spectrometry (LPGC-MS/MS), was evaluated for the analysis of polybrominated diphenyl ethers (PBDEs) and dichlorodiphenyltrichloroethane (DDT) pesticides using enzyme-linked immunosorbent assay (ELISA). The sample preparation technique was based on the quick, easy, cheap, rugged, effective, and safe (QuEChERS) approach with filter-vial dispersive solid phase extraction (d-SPE). Incurred PBDEs and DDTs were analyzed in three types of fish with 3-10% lipid content: Pacific croaker, salmon, and National Institute of Standards and Technology (NIST) Standard Reference Material 1947 (Lake Michigan fish tissue). LPGC-MS/MS and ELISA results were in agreement: 108-111 and 65-82% accuracy ELISA versus LPGC-MS/MS results for PBDEs and DDTs, respectively. Similar detection limits were achieved for ELISA and LPGC-MS/MS. Matrix effects (MEs) were significant (e.g., -60%) for PBDE measurement in ELISA, but not a factor in the case of DDT pesticides. This study demonstrated that the sample preparation method can be adopted for semiquantitative screening analysis of fish samples by commercial kits for PBDEs and DDTs.
External validation of a simple clinical tool used to predict falls in people with Parkinson disease
Duncan, Ryan P.; Cavanaugh, James T.; Earhart, Gammon M.; Ellis, Terry D.; Ford, Matthew P.; Foreman, K. Bo; Leddy, Abigail L.; Paul, Serene S.; Canning, Colleen G.; Thackeray, Anne; Dibble, Leland E.
2015-01-01
Background Assessment of fall risk in an individual with Parkinson disease (PD) is a critical yet often time consuming component of patient care. Recently a simple clinical prediction tool based only on fall history in the previous year, freezing of gait in the past month, and gait velocity <1.1 m/s was developed and accurately predicted future falls in a sample of individuals with PD. METHODS We sought to externally validate the utility of the tool by administering it to a different cohort of 171 individuals with PD. Falls were monitored prospectively for 6 months following predictor assessment. RESULTS The tool accurately discriminated future fallers from non-fallers (area under the curve [AUC] = 0.83; 95% CI 0.76 –0.89), comparable to the developmental study. CONCLUSION The results validated the utility of the tool for allowing clinicians to quickly and accurately identify an individual’s risk of an impending fall. PMID:26003412
2016-01-01
Reduced susceptibility to antimicrobials in Gram-negative bacteria may result from multiple resistance mechanisms, including increased efflux pump activity or reduced porin protein expression. Up-regulation of the efflux pump system is closely associated with multidrug resistance (MDR). To help investigate the role of efflux pumps on compound accumulation, a fluorescence-based assay was developed using fluorescent derivatives of trimethoprim (TMP), a broad-spectrum synthetic antibiotic that inhibits an intracellular target, dihydrofolate reductase (DHFR). Novel fluorescent TMP probes inhibited eDHFR activity with comparable potency to TMP, but did not kill or inhibit growth of wild type Escherichia coli. However, bactericidal activity was observed against an efflux pump deficient E. coli mutant strain (ΔtolC). A simple and quick fluorescence assay was developed to measure cellular accumulation of the TMP probe using either fluorescence spectroscopy or flow cytometry, with validation by LC-MS/MS. This fluorescence assay may provide a simple method to assess efflux pump activity with standard laboratory equipment. PMID:27737551
Stream-profile analysis and stream-gradient index
Hack, John T.
1973-01-01
The generally regular three-dimensional geometry of drainage networks is the basis for a simple method of terrain analysis providing clues to bedrock conditions and other factors that determine topographic forms. On a reach of any stream, a gradient-index value can be obtained which allows meaningful comparisons of channel slope on streams of different sizes. The index is believed to reflect stream power or competence and is simply the product of the channel slope at a point and channel length measured along the longest stream above the pointwhere the calculation is made. In an adjusted topography, changes in gradient-index values along a stream generally correspond to differences in bedrock or introduced load. In any landscape the gradient index of a stream is related to total relief and stream regimen. Thus, climate, tectonic events, and geomorphic history must be considered in using the gradient index. Gradient-index values can be obtained quickly by simple measurements on topographic maps, or they can be obtained by more sophisticated photogrammetric measurements that involve simple computer calculations from x, y, z coordinates.
Physiological Capacities: Estimating an Athlete's Potential.
ERIC Educational Resources Information Center
Lemon, Peter W. R.
1982-01-01
Several simple performance tests are described for assessing an athlete's major energy-producing capabilities. The tests are suitable for mass screening because they are easy to administer, require no sophisticated equipment, and can be done quickly. Information for evaluating test results is included. (PP)
Differential-Coil Eddy-Current Material Sorter
NASA Technical Reports Server (NTRS)
Nummelin, J.; Buckley, D.
1985-01-01
Small metal or other electrically conductive parts of same shape but different composition quickly sorted with differential-coil eddy-current sorter. Developed to distinguish between turbine blades of different alloys, hardnesses, and residual stress, sorter generally applicable to parts of simple and complex shape.
Scabies: should we always perform dermatoscopy?
Betti, S; Bassi, A; Prignano, F; Lotti, T
2009-06-01
The authors describe a case of scabies in a 80 year-old woman with a history of intense itching. Lesions were not present in the body parts where they usually occur, but few erythematous and papular lesions were visible on the rear trunk. Diagnosis was not based on the usual clinical features or on the traditional method of microscopic examination but a high magnification videodermatoscopy was performed and, on a burrow-like scabby lesions at the rear trunk, a mite was found. This paper focuses on the importance of the videodermatoscopy, a simple, quick, non-expensive and non-invasive technique, that enhances the diagnostic capability in a case of scabies, which is not localized in the characteristic zones.
Prediction: The Modern-Day Sport-Science and Sports-Medicine "Quest for the Holy Grail".
McCall, Alan; Fanchini, Maurizio; Coutts, Aaron J
2017-05-01
In high-performance sport, science and medicine practitioners employ a variety of physical and psychological tests, training and match monitoring, and injury-screening tools for a variety of reasons, mainly to predict performance, identify talented individuals, and flag when an injury will occur. The ability to "predict" outcomes such as performance, talent, or injury is arguably sport science and medicine's modern-day equivalent of the "Quest for the Holy Grail." The purpose of this invited commentary is to highlight the common misinterpretation of studies investigating association to those actually analyzing prediction and to provide practitioners with simple recommendations to quickly distinguish between methods pertaining to association and those of prediction.
NASA Astrophysics Data System (ADS)
Fuochi, P. G.; Onori, S.; Casali, F.; Chirco, P.
1993-10-01
A 12 MeV linear accelerator is currently used for electron beam processing of power semiconductor devices for lifetime control and, on an experimental basis, for food irradiation, sludge treatment etc. In order to control the irradiation process a simple, quick and reliable method for a direct evaluation of dose and fluence in a broad electron beam has been developed. This paper presents the results obtained using a "charge collector" which measures the charge absorbed in a graphite target exposed in air. Calibration of the system with super-Fricke dosimeter and comparison of absorbed dose results obtained with plastic dosimeters and alanine pellets are discussed.
NASA Astrophysics Data System (ADS)
Lawden, M. D.; Mellor, G. R.; Smalley, B.
This is a brief introduction to the Unix operating system as it is used in the Starlink Project. It is aimed at users who are new to Unix and to Starlink. Its purpose is to get you started quickly, so it is simple rather than comprehensive. It should be read in conjunction with any local guides provided at your local Starlink Site -- these give details of the local facilities available and how to use them. This is important because Starlink Sites differ in their computer hardware and in their versions of Unix. A ``Quick Reference Card" is available which summarises the contents of this note.
NASA Technical Reports Server (NTRS)
Spiegel, Seth C.; Huynh, H. T.; DeBonis, James R.
2015-01-01
High-order methods are quickly becoming popular for turbulent flows as the amount of computer processing power increases. The flux reconstruction (FR) method presents a unifying framework for a wide class of high-order methods including discontinuous Galerkin (DG), Spectral Difference (SD), and Spectral Volume (SV). It offers a simple, efficient, and easy way to implement nodal-based methods that are derived via the differential form of the governing equations. Whereas high-order methods have enjoyed recent success, they have been known to introduce numerical instabilities due to polynomial aliasing when applied to under-resolved nonlinear problems. Aliasing errors have been extensively studied in reference to DG methods; however, their study regarding FR methods has mostly been limited to the selection of the nodal points used within each cell. Here, we extend some of the de-aliasing techniques used for DG methods, primarily over-integration, to the FR framework. Our results show that over-integration does remove aliasing errors but may not remove all instabilities caused by insufficient resolution (for FR as well as DG).
A high-throughput media design approach for high performance mammalian fed-batch cultures
Rouiller, Yolande; Périlleux, Arnaud; Collet, Natacha; Jordan, Martin; Stettler, Matthieu; Broly, Hervé
2013-01-01
An innovative high-throughput medium development method based on media blending was successfully used to improve the performance of a Chinese hamster ovary fed-batch medium in shaking 96-deepwell plates. Starting from a proprietary chemically-defined medium, 16 formulations testing 43 of 47 components at 3 different levels were designed. Media blending was performed following a custom-made mixture design of experiments considering binary blends, resulting in 376 different blends that were tested during both cell expansion and fed-batch production phases in one single experiment. Three approaches were chosen to provide the best output of the large amount of data obtained. A simple ranking of conditions was first used as a quick approach to select new formulations with promising features. Then, prediction of the best mixes was done to maximize both growth and titer using the Design Expert software. Finally, a multivariate analysis enabled identification of individual potential critical components for further optimization. Applying this high-throughput method on a fed-batch, rather than on a simple batch, process opens new perspectives for medium and feed development that enables identification of an optimized process in a short time frame. PMID:23563583
Ramirez-Sanchez, Israel; Maya, Lisandro; Ceballos, Guillermo; Villarreal, Francisco
2010-12-01
Polyphenolic compounds of the flavanoid family are abundantly present in cacao seed and its cocoa products. Results from studies using cocoa products indicate beneficial effects of flavanols on cardiovascular endpoints. Evidence indicates that (-)-epicatechin is the main cacao flavanol associated with cardiovascular effects, so the accurate quantification of its content in cacao seeds or cocoa products is important. Common methods for the quantification of phenolic content in cocoa products are based on the reaction of phenols with colorimetric reagents such as the Folin-Ciocalteu (FC) In this study, we compared the FC method of phenolic determinations using 2 different standards (gallic acid and (-)-epicatechin) to construct calibration curves. We compare these results with those obtained from a simple fluorometric method (Ex(280)/Em(320) nm) used to determine catechin/(-)-epicatechin content in samples of cacao seeds and cocoa products. Values obtained from the FC method determination of polyphenols yield an overestimation of phenol (flavonoid) content when gallic acid is used as standard. Moreover, the epicatechin is a more reliable standard because of its abundance in cacao seeds and cocoa products. The use of fluorometric spectra yields a simple and highly quantitative means for a more precise and rapid quantification of cacao catechins. Fluorometric values are essentially in agreement with those reported using more cumbersome methods. In conclusion, the use of fluorescence emission spectra is a quick, practical and suitable means to quantifying catechins in cacao seeds and cocoa products.
Cup-Shaped Superparamagnetic Hemispheres for Size-Selective Cell Filtration
Kim, Hyonchol; Terazono, Hideyuki; Takei, Hiroyuki; Yasuda, Kenji
2014-01-01
We propose a new method of size separation of cells exploiting precisely size-controlled hemispherical superparamagnetic microparticles. A three-layered structure of a 2-nm nickel layer inserted between 15-nm silicon dioxide layers was formed on polystyrene cast spheres by vapor deposition. The polystyrene was then removed by burning and the hemispherical superparamagnetic microparticles, “magcups”, were obtained. The standard target cells (CCRF-CEM, 12 ± 2 μm) were mixed with a set of different sizes of the fabricated magcups, and we confirmed that the cells were captured in the magcups having cavities larger than 15 μm in diameter, and then gathered by magnetic force. The collected cells were grown in a culture medium without any damage. The results suggest that this method is quick, simple and non-invasive size separation of target cells. PMID:25219418
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendoza-Moctezuma, A. I.; Aguilar, J. Garcia; Garcia-Garduno, O. A.
Interventional cardiology procedures are an effective alternative for the reestablishment of correct sanguineous circulation in the heart. However, this kind of procedures exposes to the patients to a relatively high radiation doses. Usually, the surface peak skin dose is evaluated using a visual scale with a comparator strip, nevertheless, even if the comparator strip provides a simple and quick method for estimating the dose it has an uncertainty of {+-}25%. For this reason, a better evaluation method is needed. The objective of our project is to determine the surface peak skin dose of interventional cardiology procedures using GafChromic XR-RV2 filmmore » together with a commercial flatbed scanner in reflection mode. Here we report a protocol to handle GafChromic XR-RV2 film using a commercial flat bed scanner in reflection mode aiming at an uncertainty of {+-}3%.« less
Digitise This! A Quick and Easy Remote Sensing Method to Monitor the Daily Extent of Dredge Plumes
Evans, Richard D.; Murray, Kathy L.; Field, Stuart N.; Moore, James A. Y.; Shedrawi, George; Huntley, Barton G.; Fearns, Peter; Broomhall, Mark; McKinna, Lachlan I. W.; Marrable, Daniel
2012-01-01
Technological advancements in remote sensing and GIS have improved natural resource managers’ abilities to monitor large-scale disturbances. In a time where many processes are heading towards automation, this study has regressed to simple techniques to bridge a gap found in the advancement of technology. The near-daily monitoring of dredge plume extent is common practice using Moderate Resolution Imaging Spectroradiometer (MODIS) imagery and associated algorithms to predict the total suspended solids (TSS) concentration in the surface waters originating from floods and dredge plumes. Unfortunately, these methods cannot determine the difference between dredge plume and benthic features in shallow, clear water. This case study at Barrow Island, Western Australia, uses hand digitising to demonstrate the ability of human interpretation to determine this difference with a level of confidence and compares the method to contemporary TSS methods. Hand digitising was quick, cheap and required very little training of staff to complete. Results of ANOSIM R statistics show remote sensing derived TSS provided similar spatial results if they were thresholded to at least 3 mg L−1. However, remote sensing derived TSS consistently provided false-positive readings of shallow benthic features as Plume with a threshold up to TSS of 6 mg L−1, and began providing false-negatives (excluding actual plume) at a threshold as low as 4 mg L−1. Semi-automated processes that estimate plume concentration and distinguish between plumes and shallow benthic features without the arbitrary nature of human interpretation would be preferred as a plume monitoring method. However, at this stage, the hand digitising method is very useful and is more accurate at determining plume boundaries over shallow benthic features and is accessible to all levels of management with basic training. PMID:23240055
NASA Astrophysics Data System (ADS)
Qu, Lei; Chen, Jian-bo; Zhou, Qun; Zhang, Gui-jun; Sun, Su-qin; Guo, Yi-zhen
2016-11-01
As a kind of expensive perfume and valuable herb, the commercial Aquilariae Lignum Resinatum (ALR) is often adulterated for economic motivations. In this research, Fourier transform infrared (FT-IR) spectroscopy and two-dimensional (2D) correlation analysis are employed to establish a simple and quick identification method for the authentic and adulterated ALR. In the conventional infrared spectra, the standard ALR has a strong peak at 1658 cm-1 referring to the conjugated carbonyl of resin, while this peak is absent in the adulterated samples. The position, intensity, and shape of the auto-peaks and cross-peaks of the authentic and adulterated ALR are much different in the synchronous 2D correlation spectra with thermal perturbation. In the range of 1700-1500 cm-1, the standard ALR has four obvious auto-peaks, while the strongest one is at 1659 cm-1. The adulterated sample w-1 has three obvious auto-peaks and the strongest one is at 1647 cm-1. The adulterated sample w-2 has three obvious auto-peaks and the strongest one is at 1519 cm-1. The adulterated sample w-3 has four obvious auto-peaks and the strongest one is at 1690 cm-1. The above auto-peaks confirm that the standard ALR contains a certain content of resin compounds, while the three counterfeits contain little or different resins. The results show the potential of FT-IR spectroscopy and 2D correlation analysis in the simple and quick identification of authentic and adulterated ALR.
Simple construction and performance of a conical plastic cryocooler
NASA Technical Reports Server (NTRS)
Lambert, N.
1985-01-01
Low power cryocoolers with conical displacers offer several advantages over stepped displacers. The described fabrication process allows quick and reproducible manufacturing of plastic conical displacer units. This could be of commercial interest, but it also makes systematic optimization feasible by constructing a number of different models. The process allows for a wide range of displacer profiles. Low temperature performance as dominated by regenerator losses, and several effects are discussed. A simple device is described which controls gas flow during expansion.
Automatic document classification of biological literature
Chen, David; Müller, Hans-Michael; Sternberg, Paul W
2006-01-01
Background Document classification is a wide-spread problem with many applications, from organizing search engine snippets to spam filtering. We previously described Textpresso, a text-mining system for biological literature, which marks up full text according to a shallow ontology that includes terms of biological interest. This project investigates document classification in the context of biological literature, making use of the Textpresso markup of a corpus of Caenorhabditis elegans literature. Results We present a two-step text categorization algorithm to classify a corpus of C. elegans papers. Our classification method first uses a support vector machine-trained classifier, followed by a novel, phrase-based clustering algorithm. This clustering step autonomously creates cluster labels that are descriptive and understandable by humans. This clustering engine performed better on a standard test-set (Reuters 21578) compared to previously published results (F-value of 0.55 vs. 0.49), while producing cluster descriptions that appear more useful. A web interface allows researchers to quickly navigate through the hierarchy and look for documents that belong to a specific concept. Conclusion We have demonstrated a simple method to classify biological documents that embodies an improvement over current methods. While the classification results are currently optimized for Caenorhabditis elegans papers by human-created rules, the classification engine can be adapted to different types of documents. We have demonstrated this by presenting a web interface that allows researchers to quickly navigate through the hierarchy and look for documents that belong to a specific concept. PMID:16893465
Quick-setting concrete and a method for making quick-setting concrete
Wagh, A.S.; Singh, D.; Pullockaran, J.D.; Knox, L.
1997-04-29
A method for producing quick setting concrete is provided comprising mixing a concrete dry mixture with carbonate solution to create a slurry, and allowing the slurry to cure. The invention also provides for a quick setting concrete having a predetermined proportion of CaCO{sub 3} of between 5 and 23 weight percent of the entire concrete mixture, and whereby the concrete has a compression strength of approximately 4,000 pounds per square inch (psi) within 24 hours after pouring. 2 figs.
Quick-setting concrete and a method for making quick-setting concrete
Wagh, Arun S.; Singh, Dileep; Pullockaran, Jose D.; Knox, Lerry
1997-01-01
A method for producing quick setting concrete is provided comprising hydrng a concrete dry mixture with carbonate solution to create a slurry, and allowing the slurry to cure. The invention also provides for a quick setting concrete having a predetermined proportion of CaCO.sub.3 of between 5 and 23 weight percent of the entire concrete mixture, and whereby the concrete has a compression strength of approximately 4,000 pounds per square inch (psi) within 24 hours after pouring.
Mirus, Benjamin B.; Perkins, Kim S.
2012-01-01
The bottomless bucket (BB) approach (Nimmo et al., 2009a) is a cost-effective method for rapidly characterizing field-saturated hydraulic conductivity Kfs of soils and alluvial deposits. This practical approach is of particular value for quantifying infiltration rates in remote areas with limited accessibility. A similar approach for bedrock outcrops is also of great value for improving quantitative understanding of infiltration and recharge in rugged terrain. We develop a simple modification to the BB method for application to bedrock outcrops, which uses a non-toxic, quick-drying silicone gel to seal the BB to the bedrock. These modifications to the field method require only minor changes to the analytical solution for calculating Kfs on soils. We investigate the reproducibility of the method with laboratory experiments on a previously studied calcarenite rock and conduct a sensitivity analysis to quantify uncertainty in our predictions. We apply the BB method on both bedrock and soil for sites on Pahute Mesa, which is located in a remote area of the Nevada National Security Site. The bedrock BB tests may require monitoring over several hours to days, depending on infiltration rates, which necessitates a cover to prevent evaporative losses. Our field and laboratory results compare well to Kfs values inferred from independent reports, which suggests the modified BB method can provide useful estimates and facilitate simple hypothesis testing. The ease with which the bedrock BB method can be deployed should facilitate more rapid in-situ data collection than is possible with alternative methods for quantitative characterization of infiltration into bedrock.
THERMOSTAT FOR LOWER TEMPERATURES
Stier, T. J. B.; Crozier, W. J.
1933-01-01
Details are given concerning the construction and operation of relatively simple thermostats which permit maintaining precise temperatures down to 0°C. (with water), or temperatures above that of the ordinary room, and in which the temperature may be quickly altered at short intervals to new levels. PMID:19872736
Keith, D; Hong, B; Christensen, M
1997-05-01
A quick, simple, and efficient extraction technique was developed for the removal of protein from soft hydrophilic contact lenses. An extraction solvent consisting of a 50:50 mix of 0.2% trifluoroacetic acid and acetonitrile was used to remove protein from in vitro laboratory-deposited and human-worn contact lenses. The protein removed was analyzed using HPLC, bicinchoninic acid (BCA) analysis, and SDS-PAGE gel electreophoresis. Extraction efficiency for lysozyme from laboratory-deposited Group IV lenses was determined to be approximately 100%. Group IV human-worn contact lenses were extracted and analyzed for lysozyme by HPLC and total protein by bicinchoninic acid (BCA) analysis. Groups I, II, III, and IV contact lenses deposited with an artificial tear protein solution and human-worn lenses were extracted and analyzed by SDS-PAGE gel electreophoresis and micro-BCA. The ACN/TFA procedure offers a simple, quick, and efficient extraction technique for removal of protein from contact lenses for subsequent analysis.
Colombini, Daniela; Occhipinti, E; Di Leone, G
2012-01-01
During the last Congress of the International Ergonomics Association (IEA), Beijing, August 2009, an international group was founded aimed at developing a "toolkit for MSD prevention" within IEA and in collaboration with World Health Organization (WHO). Possible users of toolkits are: members of health and safety committees, health and safety representatives, line supervisors; labor inspectors; health workers implementing basic occupational health services; occupational health and safety specialists.According to ISO standard 11228 series and the new Draft CD ISO 12259-2009: Application document guides for the potential user, a computer software ( in Excel®) was create dealing with hazard "mapping" in handicraft The proposed methodology, using specific key enters and quick assessment criteria, allows a simple ergonomics hazard identification and risk estimation. Thus it makes possible to decide for which professional hazards a more exhaustive risk assessment will be necessary and which professional consultant should be involved (occupational physician, safety engineer, industrial hygienist, etc.).
Ten simple rules for Lightning and PechaKucha presentations.
NASA Astrophysics Data System (ADS)
Lortie, C. J.
2016-12-01
An interesting opportunity has emerged that bridges the gap between lengthy, detailed presentations of scientific findings and `sound bites' appropriate for media reporting - very short presentations often presented in sets. Lightning or Ignite (20 slides @15 seconds each) and PechaKucha (20 slides @20 seconds each) presentations are common formats for short, rapid communications at scientific conferences and public events. The simple rules for making good presentations also apply, but these presentation formats provide both unique communication opportunities and novel challenges. In the spirit of light, quick, and exact (but without the fox), here are ten simple rules for presentation formats that do not wait for the speaker.
Qu, Zhenhong; Ghorbani, Rhonda P; Li, Hongyan; Hunter, Robert L; Hannah, Christina D
2007-03-01
Gross examination, encompassing description, dissection, and sampling, is a complex task and an essential component of surgical pathology. Because of the complexity of the task, standardized protocols to guide the gross examination often become a bulky manual that is difficult to use. This problem is further compounded by the high specimen volume and biohazardous nature of the task. As a result, such a manual is often underused, leading to errors that are potentially harmful and time consuming to correct-a common chronic problem affecting many pathology laboratories. To combat this problem, we have developed a simple method that incorporates complex text and graphic information of a typical procedure manual and yet allows easy access to any intended instructive information in the manual. The method uses the Object-Linking-and-Embedding function of Microsoft Word (Microsoft, Redmond, WA) to establish hyperlinks among different contents, and then it uses the touch screen technology to facilitate navigation through the manual on a computer screen installed at the cutting bench with no need for a physical keyboard or a mouse. It takes less than 4 seconds to reach any intended information in the manual by 3 to 4 touches on the screen. A 3-year follow-up study shows that this method has increased use of the manual and has improved the quality of gross examination. The method is simple and can be easily tailored to different formats of instructive information, allowing flexible organization, easy access, and quick navigation. Increased compliance to instructive information reduces errors at the grossing bench and improves work efficiency.
Studying quick coupler efficiency in working attachment system of single-bucket power shovel
NASA Astrophysics Data System (ADS)
Duganova, E. V.; Zagorodniy, N. A.; Solodovnikov, D. N.; Korneyev, A. S.
2018-03-01
A prototype of a quick-disconnect connector (quick coupler) with an unloaded retention mechanism was developed from the analysis of typical quick couplers used as intermediate elements for power shovels of different manufacturers. A method is presented, allowing building a simulation model of the quick coupler prototype as an alternative to physical modeling for further studies.
Cui, De-Mi; Yan, Weizhong; Wang, Xiao-Quan; Lu, Lie-Min
2017-10-25
Low strain pile integrity testing (LSPIT), due to its simplicity and low cost, is one of the most popular NDE methods used in pile foundation construction. While performing LSPIT in the field is generally quite simple and quick, determining the integrity of the test piles by analyzing and interpreting the test signals (reflectograms) is still a manual process performed by experienced experts only. For foundation construction sites where the number of piles to be tested is large, it may take days before the expert can complete interpreting all of the piles and delivering the integrity assessment report. Techniques that can automate test signal interpretation, thus shortening the LSPIT's turnaround time, are of great business value and are in great need. Motivated by this need, in this paper, we develop a computer-aided reflectogram interpretation (CARI) methodology that can interpret a large number of LSPIT signals quickly and consistently. The methodology, built on advanced signal processing and machine learning technologies, can be used to assist the experts in performing both qualitative and quantitative interpretation of LSPIT signals. Specifically, the methodology can ease experts' interpretation burden by screening all test piles quickly and identifying a small number of suspected piles for experts to perform manual, in-depth interpretation. We demonstrate the methodology's effectiveness using the LSPIT signals collected from a number of real-world pile construction sites. The proposed methodology can potentially enhance LSPIT and make it even more efficient and effective in quality control of deep foundation construction.
Zhang, Miao; Liu, Yinan; Chen, Lili; Quan, Sheng; Jiang, Shimeng; Zhang, Dabing; Yang, Litao
2013-01-02
Quickness, simplicity, and effectiveness are the three major criteria for establishing a good molecular diagnosis method in many fields. Herein we report a novel detection system for genetically modified organisms (GMOs), which can be utilized to perform both on-field quick screening and routine laboratory diagnosis. In this system, a newly designed inexpensive DNA extraction device was used in combination with a modified visual loop-mediated isothermal amplification (vLAMP) assay. The main parts of the DNA extraction device included a silica gel membrane filtration column and a modified syringe. The DNA extraction device could be easily operated without using other laboratory instruments, making it applicable to an on-field GMO test. High-quality genomic DNA (gDNA) suitable for polymerase chain reaction (PCR) and isothermal amplification could be quickly isolated from plant tissues using this device within 15 min. In the modified vLAMP assay, a microcrystalline wax encapsulated detection bead containing SYBR green fluorescent dye was introduced to avoid dye inhibition and cross-contaminations from post-LAMP operation. The system was successfully applied and validated in screening and identification of GM rice, soybean, and maize samples collected from both field testing and the Grain Inspection, Packers, and Stockyards Administration (GIPSA) proficiency test program, which demonstrated that it was well-adapted to both on-field testing and/or routine laboratory analysis of GMOs.
New, Patented Technique for Naturally Restoring Healthy Vision
NASA Astrophysics Data System (ADS)
Anganes, Andrew A.; McLeod, Roger David; Machado, Milena
2009-05-01
The patented NATUROPTIC METHOD FOR RESTORING HEALTHY VISION claims to be a novel teaching method for safely and naturally improving vision. It is a simple tutoring process designed to work quickly, requiring only a minimal number of sessions for improvement. We investigated these claims, implementing Naturoptics for safe recovery of vision, ourselves, over a period of time. Research was conducted at off campus locations, mentored by the creator of the Naturoptic Method. We assessed our initial visual acuity and subsequent progress, using standard Snellen Eye Charts. Our research is designed to document successive improvements in vision, and to assess our potential for teaching the method. Naturoptics' Board encourages work-study memorial awards for students. They are: ``The David Matthew McLeod Memorial Award,'' or ``The Kaan Balam Matagamon Memorial Award,'' with net earnings shared by the designees, academic entities, the American Indians in Science and Engineering Society, AISES, or charity. The Board requires awardees, students, and associated entities, to sign non-disclosure agreements.
Lenticular card: a new method for denture identification.
Colvenkar, Shreya S
2010-01-01
The need for denture marking is important for forensic and social reasons in case patients need to be identified individually. Majority of the surface marking and inclusion techniques are expensive, time consuming, and do not permit the incorporation of large amounts of information. In this article, the method to include a lenticular identification card stood out from the currently available denture marking methods in various ways. The lenticular card stores the patient's information has two or more images that can be viewed by changing the angle of view. The maxillary denture was processed according to the manufacturer's instructions. The lenticular identification card was incorporated in the external posterior buccal surface of the maxillary denture using salt and pepper technique. For testing of durability, denture with the identifier was placed in water for up to 4 months. The proposed method is simple, cheap, and can store a large amount of information, thus allowing quick identification of the denture wearer. The labels showed no sign of fading or deterioration.
Liu, Shiyuan; Xu, Shuang; Wu, Xiaofei; Liu, Wei
2012-06-18
This paper proposes an iterative method for in situ lens aberration measurement in lithographic tools based on a quadratic aberration model (QAM) that is a natural extension of the linear model formed by taking into account interactions among individual Zernike coefficients. By introducing a generalized operator named cross triple correlation (CTC), the quadratic model can be calculated very quickly and accurately with the help of fast Fourier transform (FFT). The Zernike coefficients up to the 37th order or even higher are determined by solving an inverse problem through an iterative procedure from several through-focus aerial images of a specially designed mask pattern. The simulation work has validated the theoretical derivation and confirms that such a method is simple to implement and yields a superior quality of wavefront estimate, particularly for the case when the aberrations are relatively large. It is fully expected that this method will provide a useful practical means for the in-line monitoring of the imaging quality of lithographic tools.
Apparent Yield Strength of Hot-Pressed SiCs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daloz, William L; Wereszczak, Andrew A; Jadaan, Osama M.
2008-01-01
Apparent yield strengths (YApp) of four hot-pressed silicon carbides (SiC-B, SiC-N,SiC-HPN, and SiC-SC-1RN) were estimated using diamond spherical or Hertzian indentation. The von Mises and Tresca criteria were considered. The developed test method was robust, simple and quick to execute, and thusly enabled the acquisition of confident sampling statistics. The choice of indenter size, test method, and method of analysis are described. The compressive force necessary to initiate apparent yielding was identified postmortem using differential interference contrast (or Nomarski) imaging with an optical microscope. It was found that the YApp of SiC-HPN (14.0 GPa) was approximately 10% higher than themore » equivalently valued YApp of SiC-B, SiC-N, and SiC-SC-1RN. This discrimination in YApp shows that the use of this test method could be insightful because there were no differences among the average Knoop hardnesses of the four SiC grades.« less
Calculating p-values and their significances with the Energy Test for large datasets
NASA Astrophysics Data System (ADS)
Barter, W.; Burr, C.; Parkes, C.
2018-04-01
The energy test method is a multi-dimensional test of whether two samples are consistent with arising from the same underlying population, through the calculation of a single test statistic (called the T-value). The method has recently been used in particle physics to search for samples that differ due to CP violation. The generalised extreme value function has previously been used to describe the distribution of T-values under the null hypothesis that the two samples are drawn from the same underlying population. We show that, in a simple test case, the distribution is not sufficiently well described by the generalised extreme value function. We present a new method, where the distribution of T-values under the null hypothesis when comparing two large samples can be found by scaling the distribution found when comparing small samples drawn from the same population. This method can then be used to quickly calculate the p-values associated with the results of the test.
Sun, Juan; Li, Weixi; Zhang, Yan; Hu, Xuexu; Wu, Li; Wang, Bujun
2016-12-15
A method based on the QuEChERS (quick, easy, cheap, effective, rugged, and safe) purification combined with ultrahigh performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS), was optimized for the simultaneous quantification of 25 mycotoxins in cereals. Samples were extracted with a solution containing 80% acetonitrile and 0.1% formic acid, and purified with QuEChERS before being separated by a C18 column. The mass spectrometry was conducted by using positive electrospray ionization (ESI+) and multiple reaction monitoring (MRM) models. The method gave good linear relations with regression coefficients ranging from 0.9950 to 0.9999. The detection limits ranged from 0.03 to 15.0 µg·kg -1 , and the average recovery at three different concentrations ranged from 60.2% to 115.8%, with relative standard deviations (RSD%) varying from 0.7% to 19.6% for the 25 mycotoxins. The method is simple, rapid, accurate, and an improvement compared with the existing methods published so far.
Aldana Marcos, H J; Ferrari, C C; Benitez, I; Affanni, J M
1996-12-01
This paper reports the standardization of methods used for processing and embedding various vertebrate brains of different size in paraffin. Other technical details developed for avoiding frequent difficulties arising during laboratory routine are also reported. Some modifications of the Nissl and Klüver-Barrera staining methods are proposed. These modifications include: 1) a Nissl stain solution with a rapid and efficient action with easier differentiation; 2) the use of a cheap microwave oven for the Klüver-Barrera stain. These procedures have the advantage of permitting Nissl and Klüver-Barrera staining of nervous tissue in about five and fifteen minutes respectively. The proposed procedures have been tested in brains obtained from fish, amphibians, reptiles and mammals of different body sizes. They are the result of our long experience in preparing slides for comparative studies. Serial sections of excellent quality were regularly obtained in all the specimens studied. These standardized methods, being simple and quick, are recommended for routine use in neurobiological laboratories.
Determination of 129I in environmental samples by AMS and NAA using an anion exchange resin disk
NASA Astrophysics Data System (ADS)
Suzuki, Takashi; Banba, Shigeru; Kitamura, Toshikatsu; Kabuto, Shoji; Isogai, Keisuke; Amano, Hikaru
2007-06-01
We have developed a new extraction method for the measurement of 129I by accelerator mass spectrometry (AMS) utilizing an anion exchange resin disk. In comparison to traditional methods such as solvent extraction and ion exchange, this method provides for simple and quick sample handling. This extraction method was tested on soil, seaweed and milk samples, but because of disk clogging, the milk samples and some of the seaweed could not be applied successfully. Using this new extraction method to prepare samples for AMS analysis produced isotope ratios of iodine in good agreement with neutron activation analysis (NAA). The disk extraction method which take half an hour is faster than previous techniques, such as solvent extraction or ion exchange which take a few hours. The combination of the disk method and the AMS measurement is a powerful tool for the determination of 129I. Furthermore, these data will be available for the environmental monitoring before and during the operation of a new nuclear fuel reprocessing plant in Japan.
An Embedded Sensory System for Worker Safety: Prototype Development and Evaluation
Cho, Chunhee; Park, JeeWoong
2018-01-01
At a construction site, workers mainly rely on two senses, which are sight and sound, in order to perceive their physical surroundings. However, they are often hindered by the nature of most construction sites, which are usually dynamic, loud, and complicated. To overcome these challenges, this research explored a method using an embedded sensory system that might offer construction workers an artificial sensing ability to better perceive their surroundings. This study identified three parameters (i.e., intensity, signal length, and delay between consecutive pulses) needed for tactile-based signals for the construction workers to communicate quickly. We developed a prototype system based on these parameters, conducted experimental studies to quantify and validate the sensitivity of the parameters for quick communication, and analyzed test data to reveal what was added by this method in order to perceive information from the tactile signals. The findings disclosed that the parameters of tactile-based signals and their distinguishable ranges could be perceived in a short amount of time (i.e., a fraction of a second). Further experimentation demonstrated the capability of the identified unit signals combined with a signal mapping technique to effectively deliver simple information to individuals and offer an additional sense of awareness to the surroundings. The findings of this study could serve as a basis for future research in exploring advanced tactile-based messages to overcome challenges in environments for which communication is a struggle. PMID:29662008
An Embedded Sensory System for Worker Safety: Prototype Development and Evaluation.
Cho, Chunhee; Park, JeeWoong
2018-04-14
At a construction site, workers mainly rely on two senses, which are sight and sound, in order to perceive their physical surroundings. However, they are often hindered by the nature of most construction sites, which are usually dynamic, loud, and complicated. To overcome these challenges, this research explored a method using an embedded sensory system that might offer construction workers an artificial sensing ability to better perceive their surroundings. This study identified three parameters (i.e., intensity, signal length, and delay between consecutive pulses) needed for tactile-based signals for the construction workers to communicate quickly. We developed a prototype system based on these parameters, conducted experimental studies to quantify and validate the sensitivity of the parameters for quick communication, and analyzed test data to reveal what was added by this method in order to perceive information from the tactile signals. The findings disclosed that the parameters of tactile-based signals and their distinguishable ranges could be perceived in a short amount of time (i.e., a fraction of a second). Further experimentation demonstrated the capability of the identified unit signals combined with a signal mapping technique to effectively deliver simple information to individuals and offer an additional sense of awareness to the surroundings. The findings of this study could serve as a basis for future research in exploring advanced tactile-based messages to overcome challenges in environments for which communication is a struggle.
The National Shipbuilding Research Program. Development of a Quick TBT Analytical Method
2000-08-16
Development of a Quick TBT Analytical Method 09/25/2000 Page 3 of 38 Executive Summary Concern about the toxic effect of tributyltin have caused the...paints, developed in the 1960s, contains the organotin tributyltin ( TBT ), which has been proven to cause deformations in oysters and sex changes in...measured response (area counts) for tributyltin in deionized distilled water. Final Report – Development of a Quick TBT Analytical Method 09/25/2000
Zhao, Haixiang; Wang, Yongli; Xu, Xiuli; Ren, Heling; Li, Li; Xiang, Li; Zhong, Weike
2015-01-01
A simple and accurate authentication method for the detection of adulterated vegetable oils that contain waste cooking oil (WCO) was developed. This method is based on the determination of cholesterol, β-sitosterol, and campesterol in vegetable oils and WCO by GC/MS without any derivatization. A total of 148 samples involving 12 types of vegetable oil and WCO were analyzed. According to the results, the contents and ratios of cholesterol, β-sitosterol, and campesterol were found to be criteria for detecting vegetable oils adulterated with WCO. This method could accurately detect adulterated vegetable oils containing 5% refined WCO. The developed method has been successfully applied to multilaboratory analysis of 81 oil samples. Seventy-five samples were analyzed correctly, and only six adulterated samples could not be detected. This method could not yet be used for detection of vegetable oils adulterated with WCO that are used for frying non-animal foods. It provides a quick method for detecting adulterated edible vegetable oils containing WCO.
Solar Hot Water Heating by Natural Convection.
ERIC Educational Resources Information Center
Noble, Richard D.
1983-01-01
Presents an undergraduate laboratory experiment in which a solar collector is used to heat water for domestic use. The working fluid is moved by natural convection so no pumps are required. Experimental apparatus is simple in design and operation so that data can be collected quickly and easily. (Author/JN)
Preventing Cauliflower Ear with a Modified Tie-Through Technique.
ERIC Educational Resources Information Center
Dimeff, Robert J.; Hough, David O.
1989-01-01
Describes a quick, simple tie-through suture technique (in which a collodion packing is secured to the auricle with two buttons) for preventing cauliflower ear following external ear trauma in wrestlers and boxers. The technique ensures constant compression; multiple treatments for fluid reaccumulation are rarely necessary. (SM)
New Directions in Legal Information Processing.
ERIC Educational Resources Information Center
Chien, R. T.; And Others
The paper discusses some new developments that should evolve during the next decade in automating the handling of legal information. These new developments include: automated question-answering systems to provide quick and inexpensive answers to many non-controversial, but not necessarily simple legal questions to aid lawyers, social and welfare…
Students' Understanding of Molecular Structure and Properties of Organic Compounds.
ERIC Educational Resources Information Center
Schmidt, Hans-Jurgen
The purpose of this study was to investigate senior high school students' difficulties predicting the existence of hydrogen bridge bonds between organic molecules, investigate students' difficulties predicting the relative boiling points of simple organic compounds, and develop test questions that enable teachers to quickly get information about…
Juggling with Language Learning Theories. [Videotape
ERIC Educational Resources Information Center
Murphey, Tim
2005-01-01
Learning to juggle has become popular among corporate training programs because it shows participants how to appreciate mistakes and use "Intelligent Fast Failure" (learning quickly by daring to make a lot of simple mistakes at the beginning of a process). Big business also likes the way juggling can get executives "out of the…
Demonstrating the Light-Emitting Diode.
ERIC Educational Resources Information Center
Johnson, David A.
1995-01-01
Describes a simple inexpensive circuit which can be used to quickly demonstrate the basic function and versatility of the solid state diode. Can be used to demonstrate the light-emitting diode (LED) as a light emitter, temperature sensor, light detector with both a linear and logarithmic response, and charge storage device. (JRH)
Simplicity and Innovation Make This "Green" Brazilian City Work.
ERIC Educational Resources Information Center
Goodstein, Carol
1993-01-01
Describes how a Brazilian city, Curitiba, is successfully curbing environmental degradation through recycling efforts, transportation, housing, and land use changes. These projects include tree planting, decreased automobile use, a simple technology that enables buses to run as quickly and efficiently as subways, and increasing city open space…
A Peltier-based variable temperature source
NASA Astrophysics Data System (ADS)
Molki, Arman; Roof Baba, Abdul
2014-11-01
In this paper we propose a simple and cost-effective variable temperature source based on the Peltier effect using a commercially purchased thermoelectric cooler. The proposed setup can be used to quickly establish relatively accurate dry temperature reference points, which are necessary for many temperature applications such as thermocouple calibration.
Diane L. Haase
2011-01-01
Roots are critical to seedling performance after outplanting. Although root quality is not as quick and simple to measure as shoot quality, target root characteristics should be included in any seedling quality assessment program. This paper provides a brief review of root characteristics most commonly targeted for operational seedling production. These are: root mass...
Washing Off Polyurethane Foam Insulation
NASA Technical Reports Server (NTRS)
Burley, Richard K.; Fogel, Irving
1990-01-01
Jet of hot water removes material quickly and safely. Simple, environmentally sound technique found to remove polyurethane foam insulation from metal parts. Developed for (but not limited to) use during rebuilding of fuel system of Space Shuttle main engine, during which insulation must be removed for penetrant inspection of metal parts.
A Save-Energy, Save-Money Program That Pays Off
ERIC Educational Resources Information Center
Embersits, John F.
1976-01-01
Suggested guidelines for energy saving on campus include a 3-phase plan: (1) Quick Fix--effective management of what you already have; (2) Refitting--modification of existing systems and installation of simple controls; (3) Systems Convert--installation of computerized controls, waste-heat recovery, solid-waste recovery utilization and other…
Huang, Huafeng; Colabello, Diane M.; Sklute, Elizabeth C.; ...
2017-04-23
The absolute absorption coefficient, α(E), is a critical design parameter for devices using semiconductors for light harvesting associated with renewable energy production, both for classic technologies such as photovoltaics and for emerging technologies such as direct solar fuel production. While α(E) is well-known for many classic simple semiconductors used in photovoltaic applications, the absolute values of α(E) are typically unknown for the complex semiconductors being explored for solar fuel production due to the absence of single crystals or crystalline epitaxial films that are needed for conventional methods of determining α(E). In this work, a simple self-referenced method for estimating bothmore » the refractive indices, n(E), and absolute absorption coefficients, α(E), for loose powder samples using diffuse reflectance data is demonstrated. In this method, the sample refractive index can be deduced by refining n to maximize the agreement between the relative absorption spectrum calculated from bidirectional reflectance data (calculated through a Hapke transform which depends on n) and integrating sphere diffuse reflectance data (calculated through a Kubleka–Munk transform which does not depend on n). This new method can be quickly used to screen the suitability of emerging semiconductor systems for light-harvesting applications. The effectiveness of this approach is tested using the simple classic semiconductors Ge and Fe 2O 3 as well as the complex semiconductors La 2MoO 5 and La 4Mo 2O 11. The method is shown to work well for powders with a narrow size distribution (exemplified by Fe 2O 3) and to be ineffective for semiconductors with a broad size distribution (exemplified by Ge). As such, it provides a means for rapidly estimating the absolute optical properties of complex solids which are only available as loose powders.« less
Part-task vs. whole-task training on a supervisory control task
NASA Technical Reports Server (NTRS)
Battiste, Vernol
1987-01-01
The efficacy of a part-task training for the psychomotor portion of a supervisory control simulation was compared to that of the whole-task training, using six subjects in each group, who were asked to perform a task as quickly as possible. Part-task training was provided with the cursor-control device prior to transition to the whole-task. The analysis of both the training and experimental trials demonstrated a significant performance advantage for the part-task group: the tasks were performed better and at higher speed. Although the subjects finally achieved the same level of performance in terms of score, the part-task method was preferable for economic reasons, since simple pretraining systems are significantly less expensive than the whole-task training systems.
Multidirectional Scanning Model, MUSCLE, to Vectorize Raster Images with Straight Lines
Karas, Ismail Rakip; Bayram, Bulent; Batuk, Fatmagul; Akay, Abdullah Emin; Baz, Ibrahim
2008-01-01
This paper presents a new model, MUSCLE (Multidirectional Scanning for Line Extraction), for automatic vectorization of raster images with straight lines. The algorithm of the model implements the line thinning and the simple neighborhood methods to perform vectorization. The model allows users to define specified criteria which are crucial for acquiring the vectorization process. In this model, various raster images can be vectorized such as township plans, maps, architectural drawings, and machine plans. The algorithm of the model was developed by implementing an appropriate computer programming and tested on a basic application. Results, verified by using two well known vectorization programs (WinTopo and Scan2CAD), indicated that the model can successfully vectorize the specified raster data quickly and accurately. PMID:27879843
Multidirectional Scanning Model, MUSCLE, to Vectorize Raster Images with Straight Lines.
Karas, Ismail Rakip; Bayram, Bulent; Batuk, Fatmagul; Akay, Abdullah Emin; Baz, Ibrahim
2008-04-15
This paper presents a new model, MUSCLE (Multidirectional Scanning for Line Extraction), for automatic vectorization of raster images with straight lines. The algorithm of the model implements the line thinning and the simple neighborhood methods to perform vectorization. The model allows users to define specified criteria which are crucial for acquiring the vectorization process. In this model, various raster images can be vectorized such as township plans, maps, architectural drawings, and machine plans. The algorithm of the model was developed by implementing an appropriate computer programming and tested on a basic application. Results, verified by using two well known vectorization programs (WinTopo and Scan2CAD), indicated that the model can successfully vectorize the specified raster data quickly and accurately.
Determination of Probe Volume Dimensions in Coherent Measurement Techniques
NASA Technical Reports Server (NTRS)
Tedder, Sarah A.; Weikl, Markus C.; Seeger, Thomas; Leipertz, Alfred
2008-01-01
When investigating combustion phenomena with pump-probe techniques, the spatial resolution is given by the overlapping region of the laser beams and thus defines the probe volume size. The size of this probe volume becomes important when the length scales of interest are on the same order or smaller. In this work, we present a new approach to measure the probe volume in three dimensions (3-D), which can be used to determine the probe volume length, diameter, and shape. The optical arrangement and data evaluation are demonstrated for a dual-pump dual-broadband coherent anti-Stokes Raman scattering (CARS) setup which is used for combustion diagnostics. This new approach offers a simple, quick alternative with more capabilities than formerly used probe volume measurement methods.
Optimizing the rapid measurement of detection thresholds in infants
Jones, Pete R.; Kalwarowsky, Sarah; Braddick, Oliver J.; Atkinson, Janette; Nardini, Marko
2015-01-01
Accurate measures of perceptual threshold are difficult to obtain in infants. In a clinical context, the challenges are particularly acute because the methods must yield meaningful results quickly and within a single individual. The present work considers how best to maximize speed, accuracy, and reliability when testing infants behaviorally and suggests some simple principles for improving test efficiency. Monte Carlo simulations, together with empirical (visual acuity) data from 65 infants, are used to demonstrate how psychophysical methods developed with adults can produce misleading results when applied to infants. The statistical properties of an effective clinical infant test are characterized, and based on these, it is shown that (a) a reduced (false-positive) guessing rate can greatly increase test efficiency, (b) the ideal threshold to target is often below 50% correct, and (c) simply taking the max correct response can often provide the best measure of an infant's perceptual sensitivity. PMID:26237298
Predicting catalyst-support interactions between metal nanoparticles and amorphous silica supports
NASA Astrophysics Data System (ADS)
Ewing, Christopher S.; Veser, Götz; McCarthy, Joseph J.; Lambrecht, Daniel S.; Johnson, J. Karl
2016-10-01
Metal-support interactions significantly affect the stability and activity of supported catalytic nanoparticles (NPs), yet there is no simple and reliable method for estimating NP-support interactions, especially for amorphous supports. We present an approach for rapid prediction of catalyst-support interactions between Pt NPs and amorphous silica supports for NPs of various sizes and shapes. We use density functional theory calculations of 13 atom Pt clusters on model amorphous silica supports to determine linear correlations relating catalyst properties to NP-support interactions. We show that these correlations can be combined with fast discrete element method simulations to predict adhesion energy and NP net charge for NPs of larger sizes and different shapes. Furthermore, we demonstrate that this approach can be successfully transferred to Pd, Au, Ni, and Fe NPs. This approach can be used to quickly screen stability and net charge transfer and leads to a better fundamental understanding of catalyst-support interactions.
Single molecule targeted sequencing for cancer gene mutation detection.
Gao, Yan; Deng, Liwei; Yan, Qin; Gao, Yongqian; Wu, Zengding; Cai, Jinsen; Ji, Daorui; Li, Gailing; Wu, Ping; Jin, Huan; Zhao, Luyang; Liu, Song; Ge, Liangjin; Deem, Michael W; He, Jiankui
2016-05-19
With the rapid decline in cost of sequencing, it is now affordable to examine multiple genes in a single disease-targeted clinical test using next generation sequencing. Current targeted sequencing methods require a separate step of targeted capture enrichment during sample preparation before sequencing. Although there are fast sample preparation methods available in market, the library preparation process is still relatively complicated for physicians to use routinely. Here, we introduced an amplification-free Single Molecule Targeted Sequencing (SMTS) technology, which combined targeted capture and sequencing in one step. We demonstrated that this technology can detect low-frequency mutations using artificially synthesized DNA sample. SMTS has several potential advantages, including simple sample preparation thus no biases and errors are introduced by PCR reaction. SMTS has the potential to be an easy and quick sequencing technology for clinical diagnosis such as cancer gene mutation detection, infectious disease detection, inherited condition screening and noninvasive prenatal diagnosis.
Simple heuristic for the viscosity of polydisperse hard spheres
NASA Astrophysics Data System (ADS)
Farr, Robert S.
2014-12-01
We build on the work of Mooney [Colloids Sci. 6, 162 (1951)] to obtain an heuristic analytic approximation to the viscosity of a suspension any size distribution of hard spheres in a Newtonian solvent. The result agrees reasonably well with rheological data on monodispserse and bidisperse hard spheres, and also provides an approximation to the random close packing fraction of polydisperse spheres. The implied packing fraction is less accurate than that obtained by Farr and Groot [J. Chem. Phys. 131(24), 244104 (2009)], but has the advantage of being quick and simple to evaluate.
A new algorithm to construct phylogenetic networks from trees.
Wang, J
2014-03-06
Developing appropriate methods for constructing phylogenetic networks from tree sets is an important problem, and much research is currently being undertaken in this area. BIMLR is an algorithm that constructs phylogenetic networks from tree sets. The algorithm can construct a much simpler network than other available methods. Here, we introduce an improved version of the BIMLR algorithm, QuickCass. QuickCass changes the selection strategy of the labels of leaves below the reticulate nodes, i.e., the nodes with an indegree of at least 2 in BIMLR. We show that QuickCass can construct simpler phylogenetic networks than BIMLR. Furthermore, we show that QuickCass is a polynomial-time algorithm when the output network that is constructed by QuickCass is binary.
Li, Xue; Zhou, Yunlei; Xu, Yan; Xu, Huijie; Wang, Minghui; Yin, Huanshun; Ai, Shiyun
2016-08-31
Protein kinases are general and significant regulators in the cell signaling pathway, and it is still greatly desired to achieve simple and quick kinase detection. Herein, we develop a simple and sensitive photoelectrochemical strategy for the detection of protein kinase activity based on the bond between phosphorylated peptide and phosphorylated graphite-like carbon nitride (P-g-C3N4) conjugates triggered by Zr(4+) ion coordination. Under optimal conditions, the increased photocurrent is proportional to the protein kinase A (PKA) concentration ranging from 0.05 to 50 U/mL with a detection limit of 0.077 U/mL. Moreover, this photoelectrochemical assay can be also applied to quantitative analysis of kinase inhibition. The results indicated that the IC50 value (inhibitor concentration producing 50% inhibitor) for ellagic acid was 9.1 μM. Moreover, the developed method is further applied to detect PKA activity in real samples, which contains serum from healthy person and gastric cancer patients and breast tissue from healthy person and breast cancer patients. Therefore, the established protocol provides a new and simple tool for assay of kinase activity and its inhibitors with low cost and high sensitivity. Copyright © 2016 Elsevier B.V. All rights reserved.
cp-R, an interface the R programming language for clinical laboratory method comparisons.
Holmes, Daniel T
2015-02-01
Clinical scientists frequently need to compare two different bioanalytical methods as part of assay validation/monitoring. As a matter necessity, regression methods for quantitative comparison in clinical chemistry, hematology and other clinical laboratory disciplines must allow for error in both the x and y variables. Traditionally the methods popularized by 1) Deming and 2) Passing and Bablok have been recommended. While commercial tools exist, no simple open source tool is available. The purpose of this work was to develop and entirely open-source GUI-driven program for bioanalytical method comparisons capable of performing these regression methods and able to produce highly customized graphical output. The GUI is written in python and PyQt4 with R scripts performing regression and graphical functions. The program can be run from source code or as a pre-compiled binary executable. The software performs three forms of regression and offers weighting where applicable. Confidence bands of the regression are calculated using bootstrapping for Deming and Passing Bablok methods. Users can customize regression plots according to the tools available in R and can produced output in any of: jpg, png, tiff, bmp at any desired resolution or ps and pdf vector formats. Bland Altman plots and some regression diagnostic plots are also generated. Correctness of regression parameter estimates was confirmed against existing R packages. The program allows for rapid and highly customizable graphical output capable of conforming to the publication requirements of any clinical chemistry journal. Quick method comparisons can also be performed and cut and paste into spreadsheet or word processing applications. We present a simple and intuitive open source tool for quantitative method comparison in a clinical laboratory environment. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Biggs, Caroline I; Edmondson, Steve; Gibson, Matthew I
2015-01-01
Carbohydrate arrays are a vital tool in studying infection, probing the mechanisms of bacterial, viral and toxin adhesion and the development of new treatments, by mimicking the structure of the glycocalyx. Current methods rely on the formation of monolayers of carbohydrates that have been chemically modified with a linker to enable interaction with a functionalised surface. This includes amines, biotin, lipids or thiols. Thiol-addition to gold to form self-assembled monolayers is perhaps the simplest method for immobilisation as thiolated glycans are readily accessible from reducing carbohydrates in a single step, but are limited to gold surfaces. Here we have developed a quick and versatile methodology which enables the use of thiolated carbohydrates to be immobilised as monolayers directly onto acrylate-functional glass slides via a 'thiol-ene'/Michael-type reaction. By combining the ease of thiol chemistry with glass slides, which are compatible with microarray scanners this offers a cost effective, but also useful method to assemble arrays.
Quadtree of TIN: a new algorithm of dynamic LOD
NASA Astrophysics Data System (ADS)
Zhang, Junfeng; Fei, Lifan; Chen, Zhen
2009-10-01
Currently, Real-time visualization of large-scale digital elevation model mainly employs the regular structure of GRID based on quadtree and triangle simplification methods based on irregular triangulated network (TIN). TIN is a refined means to express the terrain surface in the computer science, compared with GRID. However, the data structure of TIN model is complex, and is difficult to realize view-dependence representation of level of detail (LOD) quickly. GRID is a simple method to realize the LOD of terrain, but contains more triangle count. A new algorithm, which takes full advantage of the two methods' merit, is presented in this paper. This algorithm combines TIN with quadtree structure to realize the view-dependence LOD controlling over the irregular sampling point sets, and holds the details through the distance of viewpoint and the geometric error of terrain. Experiments indicate that this approach can generate an efficient quadtree triangulation hierarchy over any irregular sampling point sets and achieve dynamic and visual multi-resolution performance of large-scale terrain at real-time.
NASA Astrophysics Data System (ADS)
Alexander, Kristen; Hampton, Meredith; Lopez, Rene; Desimone, Joseph
2009-03-01
When a pair of noble metal nanoparticles are brought close together, the plasmonic properties of the pair (known as a ``dimer'') give rise to intense electric field enhancements in the interstitial gap. These fields present a simple yet exquisitely sensitive system for performing single molecule surface-enhanced Raman spectroscopy (SM-SERS). Problems associated with current fabrication methods of SERS-active substrates include reproducibility issues, high cost of production and low throughput. In this study, we present a novel method for the high throughput fabrication of high quality SERS substrates. Using a polymer templating technique followed by the placement of thiolated nanoparticles through meniscus force deposition, we are able to fabricate large arrays of identical, uniformly spaced dimers in a quick, reproducible manner. Subsequent theoretical and experimental studies have confirmed the strong dependence of the SERS enhancement on both substrate geometry (e.g. dimer size, shape and gap size) and the polarization of the excitation source.
NASA Astrophysics Data System (ADS)
Alexander, Kristen; Lopez, Rene; Hampton, Meredith; Desimone, Joseph
2008-10-01
When a pair of noble metal nanoparticles are brought close together, the plasmonic properties of the pair (known as a ``dimer'') give rise to intense electric field enhancements in the interstitial gap. These fields present a simple yet exquisitely sensitive system for performing single molecule surface-enhanced Raman spectroscopy (SM-SERS). Problems associated with current fabrication methods of SERS-active substrates include reproducibility issues, high cost of production and low throughput. In this study, we present a novel method for the high throughput fabrication of high quality SERS substrates. Using a polymer templating technique followed by the placement of thiolated nanoparticles through meniscus force deposition, we are able to fabricate large arrays of identical, uniformly spaced dimers in a quick, reproducible manner. Subsequent theoretical and experimental studies have confirmed the strong dependence of the SERS enhancement on both substrate geometry (e.g. dimer size, shape and gap size) and the polarization of the excitation source.
NASA Astrophysics Data System (ADS)
Mendizabal, A.; González-Díaz, J. B.; San Sebastián, M.; Echeverría, A.
2016-07-01
This paper describes the implementation of a simple strategy adopted for the inherent shrinkage method (ISM) to predict welding-induced distortion. This strategy not only makes it possible for the ISM to reach accuracy levels similar to the detailed transient analysis method (considered the most reliable technique for calculating welding distortion) but also significantly reduces the time required for these types of calculations. This strategy is based on the sequential activation of welding blocks to account for welding direction and transient movement of the heat source. As a result, a significant improvement in distortion prediction is achieved. This is demonstrated by experimentally measuring and numerically analyzing distortions in two case studies: a vane segment subassembly of an aero-engine, represented with 3D-solid elements, and a car body component, represented with 3D-shell elements. The proposed strategy proves to be a good alternative for quickly estimating the correct behaviors of large welded components and may have important practical applications in the manufacturing industry.
Lead detection in living plant tissue using a new histochemical method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glater, R.A.B.; Hernandez, L. Jr.
1972-06-01
A quick, simple method for identifying and distinguishing lead from other heavy metals in living plants has been developed using sodium rhodizonate (C/sub 6/O/sub 6/Na/sub 2/) which forms a scarlet precipitate with lead at approximately pH 2.8. Hand sections of plant tissues are treated with rhodizonate reagent, buffered, and examined microscopically. Very little time and/or effect is required for this method. Those cells and tissues contaminated with lead turn scarlet - color intensity being directly related to concentration. Lead may be detected in quite low concentrations and, most importantly, may be observed in situ; its entry and movement through themore » plant can thus be followed. In an area of moderate traffic of Downey, California (Southeast Los Angeles), lead was found abundantly on leaves as well as on and in roots of garden-grown lettuce; origin of this lead is presumed to be from car exhausts.« less
Lin, Da; Hong, Ping; Zhang, Siheng; Xu, Weize; Jamal, Muhammad; Yan, Keji; Lei, Yingying; Li, Liang; Ruan, Yijun; Fu, Zhen F; Li, Guoliang; Cao, Gang
2018-05-01
Chromosome conformation capture (3C) technologies can be used to investigate 3D genomic structures. However, high background noise, high costs, and a lack of straightforward noise evaluation in current methods impede the advancement of 3D genomic research. Here we developed a simple digestion-ligation-only Hi-C (DLO Hi-C) technology to explore the 3D landscape of the genome. This method requires only two rounds of digestion and ligation, without the need for biotin labeling and pulldown. Non-ligated DNA was efficiently removed in a cost-effective step by purifying specific linker-ligated DNA fragments. Notably, random ligation could be quickly evaluated in an early quality-control step before sequencing. Moreover, an in situ version of DLO Hi-C using a four-cutter restriction enzyme has been developed. We applied DLO Hi-C to delineate the genomic architecture of THP-1 and K562 cells and uncovered chromosomal translocations. This technology may facilitate investigation of genomic organization, gene regulation, and (meta)genome assembly.
Detection of enteropathogenic Escherichia coli by microchip capillary electrophoresis.
Law, Wai S; Li, Sam F Y; Kricka, Larry J
2009-01-01
There is always a need to detect the presence of microorganisms, either as contaminants in food and pharmaceutical industries or bioindicators for disease diagnosis. Hence, it is important to develop efficient, rapid, and simple methods to detect microorganisms. Traditional culturing method is unsatisfactory due to its long incubation time. Molecular methods, although capable of providing a high degree of specificity, are not always useful in providing quick tests of presence or absence of microorganisms. Microchip elec-trophoresis has been recently employed to address problems associated with the detection of microorganisms due to its high versatility, selectivity, sensitivity, and short analysis times. In this work, the potential of PDMS-based microchip electrophoresis in the identification and characterization of microorganism was evaluated. Enteropathogenic E. coli (EPEC) was selected as the model microorganism. To obtain repeat-able separations, sample pretreatment was found to be essential. Microchip electrophoresis with laser-induced fluorescence detection could potentially revolutionize certain aspects of microbiology involving diagnosis, profiling of pathogens, environmental analysis, and many others areas of study.
A method for rapid quantitative assessment of biofilms with biomolecular staining and image analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larimer, Curtis J.; Winder, Eric M.; Jeters, Robert T.
Here, the accumulation of bacteria in surface attached biofilms, or biofouling, can be detrimental to human health, dental hygiene, and many industrial processes. A critical need in identifying and preventing the deleterious effects of biofilms is the ability to observe and quantify their development. Analytical methods capable of assessing early stage fouling are cumbersome or lab-confined, subjective, and qualitative. Herein, a novel photographic method is described that uses biomolecular staining and image analysis to enhance contrast of early stage biofouling. A robust algorithm was developed to objectively and quantitatively measure surface accumulation of Pseudomonas putida from photographs and results weremore » compared to independent measurements of cell density. Results from image analysis quantified biofilm growth intensity accurately and with approximately the same precision of the more laborious cell counting method. This simple method for early stage biofilm detection enables quantifiable measurement of surface fouling and is flexible enough to be applied from the laboratory to the field. Broad spectrum staining highlights fouling biomass, photography quickly captures a large area of interest, and image analysis rapidly quantifies fouling in the image.« less
A method for rapid quantitative assessment of biofilms with biomolecular staining and image analysis
Larimer, Curtis J.; Winder, Eric M.; Jeters, Robert T.; ...
2015-12-07
Here, the accumulation of bacteria in surface attached biofilms, or biofouling, can be detrimental to human health, dental hygiene, and many industrial processes. A critical need in identifying and preventing the deleterious effects of biofilms is the ability to observe and quantify their development. Analytical methods capable of assessing early stage fouling are cumbersome or lab-confined, subjective, and qualitative. Herein, a novel photographic method is described that uses biomolecular staining and image analysis to enhance contrast of early stage biofouling. A robust algorithm was developed to objectively and quantitatively measure surface accumulation of Pseudomonas putida from photographs and results weremore » compared to independent measurements of cell density. Results from image analysis quantified biofilm growth intensity accurately and with approximately the same precision of the more laborious cell counting method. This simple method for early stage biofilm detection enables quantifiable measurement of surface fouling and is flexible enough to be applied from the laboratory to the field. Broad spectrum staining highlights fouling biomass, photography quickly captures a large area of interest, and image analysis rapidly quantifies fouling in the image.« less
Kong, Ling-Quan; Pu, Ying-Hui; Ma, Shi-Kun
2008-01-01
To study how the choices of the quick vs slow protein transfer, the blotting membranes and the visualization methods influence the performance of Western blotting. The cellular proteins were abstracted from human breast cell line MDA-MB-231 for analysis with Western blotting using quick (2 h) and slow (overnight) protein transfer, different blotting membranes (nitrocellulose, PVDF and nylon membranes) and different visualization methods (ECL and DAB). In Western blotting with slow and quick protein transfer, the prestained marker presented more distinct bands on nitrocellulose membrane than on the nylon and PVDF membranes, and the latter also showed clear bands on the back of the membrane to very likely cause confusion, which did not occur with nitrocellulose membrane. PVDF membrane allowed slightly clearer visualization of the proteins with DAB method as compared with nitrocellulose and nylon membranes, and on the latter two membranes, quick protein transfer was likely to result in somehow irregular bands in comparison with slow protein transfer. With slow protein transfer and chemiluminescence for visualization, all the 3 membranes showed clear background, while with quick protein transfer, nylon membrane gave rise to obvious background noise but the other two membranes did not. Different membranes should be selected for immunoblotting according to the actual needs of the experiment. Slow transfer of the proteins onto the membranes often has better effect than quick transfer, and enhanced chemiluminescence is superior to DAB for protein visualization and allows highly specific and sensitive analysis of the protein expressions.
Design of efficient and simple interface testing equipment for opto-electric tracking system
NASA Astrophysics Data System (ADS)
Liu, Qiong; Deng, Chao; Tian, Jing; Mao, Yao
2016-10-01
Interface testing for opto-electric tracking system is one important work to assure system running performance, aiming to verify the design result of every electronic interface matching the communication protocols or not, by different levels. Opto-electric tracking system nowadays is more complicated, composed of many functional units. Usually, interface testing is executed between units manufactured completely, highly depending on unit design and manufacture progress as well as relative people. As a result, it always takes days or weeks, inefficiently. To solve the problem, this paper promotes an efficient and simple interface testing equipment for opto-electric tracking system, consisting of optional interface circuit card, processor and test program. The hardware cards provide matched hardware interface(s), easily offered from hardware engineer. Automatic code generation technique is imported, providing adaption to new communication protocols. Automatic acquiring items, automatic constructing code architecture and automatic encoding are used to form a new program quickly with adaption. After simple steps, a standard customized new interface testing equipment with matching test program and interface(s) is ready for a waiting-test system in minutes. The efficient and simple interface testing equipment for opto-electric tracking system has worked for many opto-electric tracking system to test entire or part interfaces, reducing test time from days to hours, greatly improving test efficiency, with high software quality and stability, without manual coding. Used as a common tool, the efficient and simple interface testing equipment for opto-electric tracking system promoted by this paper has changed traditional interface testing method and created much higher efficiency.
Nguyen, Phuong H
2007-05-15
Principal component analysis is a powerful method for projecting multidimensional conformational space of peptides or proteins onto lower dimensional subspaces in which the main conformations are present, making it easier to reveal the structures of molecules from e.g. molecular dynamics simulation trajectories. However, the identification of all conformational states is still difficult if the subspaces consist of more than two dimensions. This is mainly due to the fact that the principal components are not independent with each other, and states in the subspaces cannot be visualized. In this work, we propose a simple and fast scheme that allows one to obtain all conformational states in the subspaces. The basic idea is that instead of directly identifying the states in the subspace spanned by principal components, we first transform this subspace into another subspace formed by components that are independent of one other. These independent components are obtained from the principal components by employing the independent component analysis method. Because of independence between components, all states in this new subspace are defined as all possible combinations of the states obtained from each single independent component. This makes the conformational analysis much simpler. We test the performance of the method by analyzing the conformations of the glycine tripeptide and the alanine hexapeptide. The analyses show that our method is simple and quickly reveal all conformational states in the subspaces. The folding pathways between the identified states of the alanine hexapeptide are analyzed and discussed in some detail. 2007 Wiley-Liss, Inc.
NASA Astrophysics Data System (ADS)
Wang, Xuan-yu; Hu, Rui; Wang, Rui-xin
2015-10-01
A simple method has been set up to quickly test the emissivity with an infrared thermal imaging system within a small distance according to the theory of measuring temperature by infrared system, which is based on the Planck radiation law and Lambert-beer law. The object's temperature is promoted and held on by a heater while a temperature difference has been formed between the target and environment. The emissivity of human skin, galvanized iron plate, black rubber and liquid water has been tested under the condition that the emissivity is set in 1.0 and the testing distance is 1m. According to the invariance of human's body temperature, a testing curve is established to describe that the thermal imaging temperatures various with the emissivity which is set in from 0.9 to 1.0. As a result, the method has been verified. The testing results show that the emissivity of human skin is 0.95. The emissivity of galvanized iron plate, black rubber and liquid water decreases with the increase of object's temperature. The emissivity of galvanized iron plate is far smaller than the one of human skin, black rubber or water. The emissivity of water slowly linearly decreases with the increase of its temperature. By the study, within a small distance and clean atmosphere, the infrared emissivity of objects may be expediently tested with an infrared thermal imaging system according to the method, which is promoting the object's temperature to make it different from the environment temperature, then simultaneously measures the environmental temperature, the real temperature and thermal imaging temperature of the object when the emissivity is set in 1.0 and the testing distance is 1.0m.
Users manual for the Texas quick-load method for foundation load testing.
DOT National Transportation Integrated Search
1976-12-01
The Texas State Department of Highways and Public Transportation has developed and implemented a "quick-load" method for load testing piling and drilled shafts. Using this method a load test can be completed in a relatively short time of one to two...
Improved response functions for gamma-ray skyshine analyses
NASA Astrophysics Data System (ADS)
Shultis, J. K.; Faw, R. E.; Deng, X.
1992-09-01
A computationally simple method, based on line-beam response functions, is refined for estimating gamma skyshine dose rates. Critical to this method is the availability of an accurate approximation for the line-beam response function (LBRF). In this study, the LBRF is evaluated accurately with the point-kernel technique using recent photon interaction data. Various approximations to the LBRF are considered, and a three parameter formula is selected as the most practical approximation. By fitting the approximating formula to point-kernel results, a set of parameters is obtained that allows the LBRF to be quickly and accurately evaluated for energies between 0.01 and 15 MeV, for source-to-detector distances from 1 to 3000 m, and for beam angles from 0 to 180 degrees. This re-evaluation of the approximate LBRF gives better accuracy, especially at low energies, over a greater source-to-detector range than do previous LBRF approximations. A conical beam response function is also introduced for application to skyshine sources that are azimuthally symmetric about a vertical axis. The new response functions are then applied to three simple skyshine geometries (an open silo geometry, an infinite wall, and a rectangular four-wall building) and the results are compared to previous calculations and benchmark data.
Improved response functions for gamma-ray skyshine analyses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shultis, J.K.; Faw, R.E.; Deng, X.
1992-09-01
A computationally simple method, based on line-beam response functions, is refined for estimating gamma skyshine dose rates. Critical to this method is the availability of an accurate approximation for the line-beam response function (LBRF). In this study the LBRF is evaluated accurately with the point-kernel technique using recent photon interaction data. Various approximations to the LBRF are considered, and a three parameter formula is selected as the most practical approximation. By fitting the approximating formula to point-kernel results, a set of parameters is obtained that allows the LBRF to be quickly and accurately evaluated for energies between 0.01 and 15more » MeV, for source-to-detector distances from 1 to 3000 m, and for beam angles from 0 to 180 degrees. This reevaluation of the approximate LBRF gives better accuracy, especially at low energies, over a greater source-to-detector range than do previous LBRF approximations. A conical beam response function is also introduced for application to skyshine sources that are azimuthally symmetric about a vertical axis. The new response functions are then applied to three simple skyshine geometries (an open silo geometry, an infinite wall, and a rectangular four-wall building) and the results compared to previous calculations and benchmark data.« less
Synthesis and Characterization of Silver Nanoparticles for an Undergraduate Laboratory
ERIC Educational Resources Information Center
Orbaek, Alvin W.; McHale, Mary M.; Barron, Andrew R.
2015-01-01
The aim of this simple, quick, and safe laboratory exercise is to provide undergraduate students an introduction to nanotechnology using nanoparticle (NP) synthesis. Students are provided two procedures that allow for the synthesis of different yet controlled sizes of silver NPs. After preparing the NPs, the students perform UV-visible…
Treb-Bot: Development and Use of a Trebuchet Simulator
ERIC Educational Resources Information Center
Constans, Eric; Constans, Aileen
2015-01-01
The trebuchet has quickly become a favorite project for physics and engineering teachers seeking to provide students with a simple, but spectacular, hands-on design project that can be applied to the study of projectile motion, rotational motion, and the law of conservation of energy. While there have been free trebuchet simulators and range…
Concordancing for Schools: Problems and Potential.
ERIC Educational Resources Information Center
Pickard, Valerie; And Others
The value and role of concordancers (simple computer programs that can quickly analyze electronic texts to find occurrences of a given word, part of a word, or phrase and display it within its immediate context) in secondary school English-as-a-Second-Language (ESL) teaching are examined. First, their use in higher education is discussed,…
Optimize Resources and Help Reduce Cost of Ownership with Dell[TM] Systems Management
ERIC Educational Resources Information Center
Technology & Learning, 2008
2008-01-01
Maintaining secure, convenient administration of the PC system environment can be a significant drain on resources. Deskside visits can greatly increase the cost of supporting a large number of computers. Even simple tasks, such as tracking inventory or updating software, quickly become expensive when they require physically visiting every…
The Role of Contingency Awareness in Single-Cue Human Eyeblink Conditioning
ERIC Educational Resources Information Center
Weidemann, Gabrielle; Best, Erin; Lee, Jessica C; Lovibond, Peter F.
2013-01-01
Single-cue delay eyeblink conditioning is presented as a prototypical example of automatic, nonsymbolic learning that is carried out by subcortical circuits. However, it has been difficult to assess the role of cognition in single-cue conditioning because participants become aware of the simple stimulus contingency so quickly. In this experiment…
Using Response Interruption and Redirection to Reduce Vocal Stereotypy
ERIC Educational Resources Information Center
Sheehey, Patricia H.; Wells, Jenny C.
2018-01-01
Response interruption and redirection, commonly referred to as RIR, is an evidence-based intervention that has been demonstrated to quickly reduce moderate to high levels of vocal stereotypy in children with autism spectrum disorder. The RIR intervention is a simple, three-step procedure that can be embedded in classroom instruction with minimal…
ERIC Educational Resources Information Center
Lucking, Robert A.; Christmann, Edwin P.; Whiting, Mervyn J.
2008-01-01
"Mashup" is a new technology term used to describe a web application that combines data or technology from several different sources. You can apply this concept in your classroom by having students create their own mashup maps. Google Maps provides you with the simple tools, map databases, and online help you'll need to quickly master this…
ERIC Educational Resources Information Center
Tetlow, Linda
2009-01-01
Emergency shelters for disaster relief are an ever present necessity. Anyone who has ever camped in a tent will understand that finding the perfect design, that will be simple and quick to erect, be stable in a variety of weather conditions, and will accommodate a number of people sleeping, sitting or even standing is not straightforward and…
Centers Made Simple: A Management and Activity Guide
ERIC Educational Resources Information Center
Reynolds, Laureen
2005-01-01
Drawing from her own experiences, teacher and author Laureen Reynolds shares management strategies, helpful suggestions, and quick tips to take the mystery out of setting up centers and demonstrates how to make the most of valuable classroom time. The activities outlined in this book are designed to appeal to students of all abilities, and range…
Bakeout Chamber Within Vacuum Chamber
NASA Technical Reports Server (NTRS)
Taylor, Daniel M.; Soules, David M.; Barengoltz, Jack B.
1995-01-01
Vacuum-bakeout apparatus for decontaminating and measuring outgassing from pieces of equipment constructed by mounting bakeout chamber within conventional vacuum chamber. Upgrade cost effective: fabrication and installation of bakeout chamber simple, installation performed quickly and without major changes in older vacuum chamber, and provides quantitative data on outgassing from pieces of equipment placed in bakeout chamber.
Mac A. Callaham; Arthur J. Stewart; Clara Alarcon; Sara J. McMillen
2002-01-01
Current bioremediation techniques for petroleum-contaminated soils are designed to remove contaminants as quickly and efficiently as possible, but not necessarily with postremediation soil biological quality as a primary objective. To test a simple postbioremediation technique, we added earthworms (Eisenia fetida) or wheat (Triticum aestivum...
A Sports Franchise Simulation Game
ERIC Educational Resources Information Center
Surdam, David G.
2009-01-01
Students in sports economics courses might better learn the basic concepts by running their own franchise. A simple game, based on the card game War, is easy and inexpensive to implement. Students quickly grasp the importance of weighing marginal benefits, both in terms of team record and marginal revenue, against the costs of improving their…
COPD Learn More Breathe Better® | NIH MedlinePlus the Magazine
... this may be related to COPD. SUGGEST AN OFFICE VISIT A doctor or health care provider can diagnose COPD with a simple breathing test called spirometry. It's quick, painless—and worth it. ENCOURAGE YOUR LOVED ONE TO BE A GOOD "MANAGER." Once diagnosed, there are many ways that your ...
Chu, Steven
2017-12-27
By installing a cool roof at DOE, the federal government and Secretary Chu are helping to educate families and businesses about the important energy and cost savings that can come with this simple, low-cost technology. Cool roofs have the potential to quickly and dramatically reduce global carbon emissions while saving money every month on consumers' electrical bills.
Inertial Navigation: A Bridge between Kinematics and Calculus
ERIC Educational Resources Information Center
Sadler, Philip M.; Garfield, Eliza N.; Tremblay, Alex; Sadler, Daniel J.
2012-01-01
Those who come to Cambridge soon learn that the fastest route between Harvard and MIT is by the subway. For many students, this short ride is a quick and easy way to link physics and calculus. A simple, homemade accelerometer provides all the instrumentation necessary to produce accurate graphs of acceleration, velocity, and displacement position…
Simple Ways to Make Real Capacitors
ERIC Educational Resources Information Center
Herman, Rhett
2014-01-01
Many of us have grabbed two pieces of aluminum foil and a paper towel, quickly sandwiched them together, and exclaimed in lecture, "Look! It's easy to make a capacitor!" Then we move on from there, calculating things such as capacitances with various dielectrics or plate sizes, the capacitance of capacitor networks, RC circuits,…
Writing by Number: Teaching Students to Read the Balance Sheet.
ERIC Educational Resources Information Center
Cross, Mary
1990-01-01
Describes an assignment in which students write a short memo report analyzing and comparing both what a company says in its annual report and what its balance sheet shows. Describes four simple mathematical formulas students can use to quickly diagnose a company's financial health. Appends a sample of the short report format. (RS)
Difference-Equation/Flow-Graph Circuit Analysis
NASA Technical Reports Server (NTRS)
Mcvey, I. M.
1988-01-01
Numerical technique enables rapid, approximate analyses of electronic circuits containing linear and nonlinear elements. Practiced in variety of computer languages on large and small computers; for circuits simple enough, programmable hand calculators used. Although some combinations of circuit elements make numerical solutions diverge, enables quick identification of divergence and correction of circuit models to make solutions converge.
ERIC Educational Resources Information Center
Wardrip, Peter; Evancho, Jeffrey; McNamara, Annie
2018-01-01
A question like "what do you want your children to be like when they leave your class?" seems simple on the surface, but it quickly becomes complex when teachers are asked to name, prioritize, and document the kinds of student learning and engagement they value most. This article shares the ongoing work of a regional learning community…
Using R in Introductory Statistics Courses with the pmg Graphical User Interface
ERIC Educational Resources Information Center
Verzani, John
2008-01-01
The pmg add-on package for the open source statistics software R is described. This package provides a simple to use graphical user interface (GUI) that allows introductory statistics students, without advanced computing skills, to quickly create the graphical and numeric summaries expected of them. (Contains 9 figures.)
Modeling the Compact Disc Read System in Lab
ERIC Educational Resources Information Center
Hinaus, Brad; Veum, Mick
2009-01-01
One of the great, engaging aspects of physics is its application to everyday technology. The compact disc player is an example of one such technology that applies fundamental principles from optics in order to efficiently store and quickly retrieve information. We have created a lab in which students use simple optical components to assemble a…
Industrial plastics waste: Identification and segregation
NASA Technical Reports Server (NTRS)
Widener, Edward L.
1990-01-01
Throwaway plastic products, mainly packaging, are inundating our landfills and incinerators. Most are ethenic thermoplastics, which can be recycled as new products or fossil-fuels. Lab experiments are described, involving destructive and non-destructive tests for identifying and using plastics. The burn-test, with simple apparatus and familiar samples, is recommended as quick, cheap and effective.
Andújar Márquez, José Manuel; Martínez Bohórquez, Miguel Ángel; Gómez Melgar, Sergio
2017-09-03
This paper deals with the thermal transmittance measurement focused on buildings and specifically in building energy retrofitting. Today, if many thermal transmittance measurements in a short time are needed, the current devices, based on the measurement of the heat flow through the wall, cannot carry out them, except if a great amount of devices are used at once along with intensive and tedious post-processing and analysis work. In this paper, from well-known physical laws, authors develop a methodology based on three temperatures measurements, which is implemented by a novel thermal transmittance metre. The paper shows its development step by step. As a result the developed device is modular, scalable, and fully wireless; it is capable of taking as many measurements at once as user needs. The developed system is compared working together on a same test to the currently used one based on heat flow. The results show that the developed metre allows carrying out thermal transmittance measurements in buildings in a cheap, quick, reliable and simple way.
Joint action syntax in Japanese martial arts.
Yamamoto, Yuji; Yokoyama, Keiko; Okumura, Motoki; Kijima, Akifumi; Kadota, Koji; Gohara, Kazutoshi
2013-01-01
Participation in interpersonal competitions, such as fencing or Japanese martial arts, requires players to make instantaneous decisions and execute appropriate motor behaviors in response to various situations. Such actions can be understood as complex phenomena emerging from simple principles. We examined the intentional switching dynamics associated with continuous movement during interpersonal competition in terms of their emergence from a simple syntax. Linear functions on return maps identified two attractors as well as the transitions between them. The effects of skill differences were evident in the second- and third-order state-transition diagrams for these two attractors. Our results suggest that abrupt switching between attractors is related to the diverse continuous movements resulting from quick responses to sudden changes in the environment. This abrupt-switching-quick-response behavior is characterized by a joint action syntax. The resulting hybrid dynamical system is composed of a higher module with discrete dynamics and a lower module with continuous dynamics. Our results suggest that intelligent human behavior and robust autonomy in real-life scenarios are based on this hybrid dynamical system, which connects interpersonal coordination and competition.
Manzanera-Estrada, Mayra E; Cruz-Ramírez, Marisela; Flores-Alamo, Marcos; Gracia Y Jiménez, José Miguel; Galindo-Murillo, Rodrigo; García-Ramos, Juan Carlos; Ruiz-Azuara, Lena; Ortiz-Frade, Luis
2017-10-01
In this work we report a series of Cu(II) complexes [Cu(N-N) 2 (X)] + , (N-N=substituted 1,10-phenanthroline derivatives and X=Cl - or NO 3 - ), with tunable E 1/2 for electrochemical reduction [Cu II (N-N) 2 (X)] + +1e - ⇌[Cu I (N-N) 2 ]+X - . The disproportion of O 2 •- was explored in presence of the electro-generated species [Cu I (N-N) 2 ] + using cyclic voltammetry in a non-aqueous media, arising a new simple method to propose a SOD-like mechanism, which can be used as a quick guide test for a compound, before being proven in biological assays. It was found that complexes with high negative half wave potential values (E 1/2 ) for Cu(II)/Cu(I) couple shown a current increment for oxygen reduction, related to the capability of the disproportion of this reactive oxygen species. Copyright © 2017 Elsevier Inc. All rights reserved.
Forsman, Zac H.; Toonen, Robert J.
2018-01-01
Species within the scleractinian genus Pocillopora Lamarck 1816 exhibit extreme phenotypic plasticity, making identification based on morphology difficult. However, the mitochondrial open reading frame (mtORF) marker provides a useful genetic tool for identification of most species in this genus, with a notable exception of P. eydouxi and P. meandrina. Based on recent genomic work, we present a quick and simple, gel-based restriction fragment length polymorphism (RFLP) method for the identification of all six Pocillopora species occurring in Hawai‘i by amplifying either the mtORF region, a newly discovered histone region, or both, and then using the restriction enzymes targeting diagnostic sequences we unambiguously identify each species. Using this approach, we documented frequent misidentification of Pocillopora species based on colony morphology. We found that P. acuta colonies are frequently mistakenly identified as P. damicornis in Kāne‘ohe Bay, O‘ahu. We also found that P. meandrina likely has a northern range limit in the Northwest Hawaiian Islands, above which P. ligulata was regularly mistaken for P. meandrina. PMID:29441239
Murillo Pulgarín, José A; García Bermejo, Luisa F; Durán, Armando Carrasquero
2018-03-07
High-performance liquid chromatography (HPLC) was used to separate oxamyl from other pesticides in drinking water and tomato paste. The eluate emerging from the column tail was mixed with an alkaline solution of Co 2+ in EDTA and irradiated with UV light to induce photolysis of the carbamate in order to obtain free radicals and other reactive species that oxidize luminol and produce chemiluminescence (CL) as a result. The intensity of the CL signal was monitored in the form of chromatographic peaks. Under the optimum operating conditions for the HPLC-UV-CL system, the analyte concentration was linearly related to peak area. The limit of detection as determined in accordance with the IUPAC criterion was 0.17 mg L -1 . Oxamyl was successfully extracted with recoveries of 88.7-103.1% from spiked tomato paste by using a simple QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) sample preparation approach. Similar recoveries were obtained from drinking water samples spiked with oxamyl concentrations above the LOD. The proposed method is a simple, fast, accurate choice for quantifying this pesticide.
Developing a protocol for creating microfluidic devices with a 3D printer, PDMS, and glass
NASA Astrophysics Data System (ADS)
Collette, Robyn; Novak, Eric; Shirk, Kathryn
2015-03-01
Microfluidics research requires the design and fabrication of devices that have the ability to manipulate small volumes of fluid, typically ranging from microliters to picoliters. These devices are used for a wide range of applications including the assembly of materials and testing of biological samples. Many methods have been previously developed to create microfluidic devices, including traditional nanolithography techniques. However, these traditional techniques are cost-prohibitive for many small-scale laboratories. This research explores a relatively low-cost technique using a 3D printed master, which is used as a template for the fabrication of polydimethylsiloxane (PDMS) microfluidic devices. The masters are designed using computer aided design (CAD) software and can be printed and modified relatively quickly. We have developed a protocol for creating simple microfluidic devices using a 3D printer and PDMS adhered to glass. This relatively simple and lower-cost technique can now be scaled to more complicated device designs and applications. Funding provided by the Undergraduate Research Grant Program at Shippensburg University and the Student/Faculty Research Engagement Grants from the College of Arts and Sciences at Shippensburg University.
Prediction and measurements of vibrations from a railway track lying on a peaty ground
NASA Astrophysics Data System (ADS)
Picoux, B.; Rotinat, R.; Regoin, J. P.; Le Houédec, D.
2003-10-01
This paper introduces a two-dimensional model for the response of the ground surface due to vibrations generated by a railway traffic. A semi-analytical wave propagation model is introduced which is subjected to a set of harmonic moving loads and based on a calculation method of the dynamic stiffness matrix of the ground. In order to model a complete railway system, the effect of a simple track model is taken into account including rails, sleepers and ballast especially designed for the study of low vibration frequencies. The priority has been given to a simple formulation based on the principle of spatial Fourier transforms compatible with good numerical efficiency and yet providing quick solutions. In addition, in situ measurements for a soft soil near a railway track were carried out and will be used to validate the numerical implementation. The numerical and experimental results constitute a significant body of useful data to, on the one hand, characterize the response of the environment of tracks and, on the other hand, appreciate the importance of the speed and weight on the behaviour of the structure.
Cui, De-Mi; Wang, Xiao-Quan; Lu, Lie-Min
2017-01-01
Low strain pile integrity testing (LSPIT), due to its simplicity and low cost, is one of the most popular NDE methods used in pile foundation construction. While performing LSPIT in the field is generally quite simple and quick, determining the integrity of the test piles by analyzing and interpreting the test signals (reflectograms) is still a manual process performed by experienced experts only. For foundation construction sites where the number of piles to be tested is large, it may take days before the expert can complete interpreting all of the piles and delivering the integrity assessment report. Techniques that can automate test signal interpretation, thus shortening the LSPIT’s turnaround time, are of great business value and are in great need. Motivated by this need, in this paper, we develop a computer-aided reflectogram interpretation (CARI) methodology that can interpret a large number of LSPIT signals quickly and consistently. The methodology, built on advanced signal processing and machine learning technologies, can be used to assist the experts in performing both qualitative and quantitative interpretation of LSPIT signals. Specifically, the methodology can ease experts’ interpretation burden by screening all test piles quickly and identifying a small number of suspected piles for experts to perform manual, in-depth interpretation. We demonstrate the methodology’s effectiveness using the LSPIT signals collected from a number of real-world pile construction sites. The proposed methodology can potentially enhance LSPIT and make it even more efficient and effective in quality control of deep foundation construction. PMID:29068431
NASA Technical Reports Server (NTRS)
Perino, Scott; Bayandor, Javid; Siddens, Aaron
2012-01-01
The anticipated NASA Mars Sample Return Mission (MSR) requires a simple and reliable method in which to return collected Martian samples back to earth for scientific analysis. The Multi-Mission Earth Entry Vehicle (MMEEV) is NASA's proposed solution to this MSR requirement. Key aspects of the MMEEV are its reliable and passive operation, energy absorbing foam-composite structure, and modular impact sphere (IS) design. To aid in the development of an EEV design that can be modified for various missions requirements, two fully parametric finite element models were developed. The first model was developed in an explicit finite element code and was designed to evaluate the impact response of the vehicle and payload during the final stage of the vehicle's return to earth. The second model was developed in an explicit code and was designed to evaluate the static and dynamic structural response of the vehicle during launch and reentry. In contrast to most other FE models, built through a Graphical User Interface (GUI) pre-processor, the current model was developed using a coding technique that allows the analyst to quickly change nearly all aspects of the model including: geometric dimensions, material properties, load and boundary conditions, mesh properties, and analysis controls. Using the developed design tool, a full range of proposed designs can quickly be analyzed numerically and thus the design trade space for the EEV can be fully understood. An engineer can then quickly reach the best design for a specific mission and also adapt and optimize the general design for different missions.
NASA Astrophysics Data System (ADS)
Lea, J.
2017-12-01
The quantification of glacier change is a key variable within glacier monitoring, with the method used potentially being crucial to ensuring that data can be appropriately compared with environmental data. The topic and timescales of study (e.g. land/marine terminating environments; sub-annual/decadal/centennial/millennial timescales) often mean that different methods are more suitable for different problems. However, depending on the GIS/coding expertise of the user, some methods can potentially be time consuming to undertake, making large-scale studies problematic. In addition, examples exist where different users have nominally applied the same methods in different studies, though with minor methodological inconsistencies in their approach. In turn, this will have implications for data homogeneity where regional/global datasets may be constructed. Here, I present a simple toolbox scripted in a Matlab® environment that requires only glacier margin and glacier centreline data to quantify glacier length, glacier change between observations, rate of change, in addition to other metrics. The toolbox includes the option to apply the established centreline or curvilinear box methods, or a new method: the variable box method - designed for tidewater margins where box width is defined as the total width of the individual terminus observation. The toolbox is extremely flexible, and has the option to be applied as either Matlab® functions within user scripts, or via a graphical user interface (GUI) for those unfamiliar with a coding environment. In both instances, there is potential to apply the methods quickly to large datasets (100s-1000s of glaciers, with potentially similar numbers of observations each), thus ensuring large scale methodological consistency (and therefore data homogeneity) and allowing regional/global scale analyses to be achievable for those with limited GIS/coding experience. The toolbox has been evaluated against idealised scenarios demonstrating its accuracy, while feedback from undergraduate students who have trialled the toolbox is that it is intuitive and simple to use. When released, the toolbox will be free and open source allowing users to potentially modify, improve and expand upon the current version.
Ishikawa, Hiroshi; Kasahara, Kohei; Sato, Sumie; Shimakawa, Yasuhisa; Watanabe, Koichi
2014-05-16
Yeast contamination is a serious problem in the food industry and a major cause of food spoilage. Several yeasts, such as Filobasidiella neoformans, which cause cryptococcosis in humans, are also opportunistic pathogens, so a simple and rapid method for monitoring yeast contamination in food is essential. Here, we developed a simple and rapid method that utilizes loop-mediated isothermal amplification (LAMP) for the detection of F. neoformans. A set of five specific LAMP primers was designed that targeted the 5.8S-26S rDNA internal transcribed spacer 2 region of F. neoformans, and the primer set's specificity was confirmed. In a pure culture of F. neoformans, the LAMP assay had a lower sensitivity threshold of 10(2)cells/mL at a runtime of 60min. In a probiotic dairy product artificially contaminated with F. neoformans, the LAMP assay also had a lower sensitivity threshold of 10(2)cells/mL, which was comparable to the sensitivity of a quantitative PCR (qPCR) assay. We also developed a simple two-step method for the extraction of DNA from a probiotic dairy product that can be performed within 15min. This method involves initial protease treatment of the test sample at 45°C for 3min followed by boiling at 100°C for 5min under alkaline conditions. In a probiotic dairy product artificially contaminated with F. neoformans, analysis by means of our novel DNA extraction method followed by LAMP with our specific primer set had a lower sensitivity threshold of 10(3)cells/mL at a runtime of 60min. In contrast, use of our novel method of DNA extraction followed by qPCR assay had a lower sensitivity threshold of only 10(5)cells/mL at a runtime of 3 to 4h. Therefore, unlike the PCR assay, our LAMP assay can be used to quickly evaluate yeast contamination and is sensitive even for crude samples containing bacteria or background impurities. Our study provides a powerful tool for the primary screening of large numbers of food samples for yeast contamination. Copyright © 2014 Elsevier B.V. All rights reserved.
A fast forward algorithm for real-time geosteering of azimuthal gamma-ray logging.
Qin, Zhen; Pan, Heping; Wang, Zhonghao; Wang, Bintao; Huang, Ke; Liu, Shaohua; Li, Gang; Amara Konaté, Ahmed; Fang, Sinan
2017-05-01
Geosteering is an effective method to increase the reservoir drilling rate in horizontal wells. Based on the features of an azimuthal gamma-ray logging tool and strata spatial location, a fast forward calculation method of azimuthal gamma-ray logging is deduced by using the natural gamma ray distribution equation in formation. The response characteristics of azimuthal gamma-ray logging while drilling in the layered formation models with different thickness and position are simulated and summarized by using the method. The result indicates that the method calculates quickly, and when the tool nears a boundary, the method can be used to identify the boundary and determine the distance from the logging tool to the boundary in time. Additionally, the formation parameters of the algorithm in the field can be determined after a simple method is proposed based on the information of an offset well. Therefore, the forward method can be used for geosteering in the field. A field example validates that the forward method can be used to determine the distance from the azimuthal gamma-ray logging tool to the boundary for geosteering in real-time. Copyright © 2017 Elsevier Ltd. All rights reserved.
SU-E-T-662: Quick and Efficient Daily QA for Compact PBS Proton Therapy Machine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patel, B; Syh, J; Ding, X
2015-06-15
Purpose: As proton therapy machines become widespread the need for a quick simple routine daily QA like that for linear accelerators becomes more important. Willis-Knighton has developed an accurate and efficient daily QA that can be performed in 15 minutes. Methods: A holder for a 2D ionization chamber array (MatriXX PT) was created that is indexed to the couch to allow for quick setup, lasers accuracy with respect to beam isocenter, and couch reproducibility. Image position/reposition was performed to check Isocentricity accuracy by placing BBs on the MatriXX. The couch coordinates are compared to that of commissioning. Laser positions weremore » confirmed with the MatriXX isocenter. After IGRT, three beams were separately delivered according to setup. For the first beam, range shifter was inserted and dose at R90, field size, flatness and symmetry in X and Y direction was measured. R90 was used so any minor changes in the range shifter can be detected. For the open beam, dose at center of SOBP, flatness and symmetry in X and Y direction was measured. Field size was measured in ±X and ±Y direction at FWHM. This is measured so any variation in spot size will be detected. For the third beam additional solid water was added and dose at R50 was measured so that any variation in beam energy will be detected. Basic mechanical and safety checks were also performed. Results: Medical physicists were able to complete the daily QA and reduce the time by half to two-third from initial daily QA procedure. All the values measured were within tolerance of that of the baseline which was established from water tank and initial MatriXX measurements. Conclusion: The change in daily QA procedure resulted in quick and easy setup and was able to measure all the basic functionality of the proton therapy PBS.« less
López-Carbonell, Marta; Gabasa, Marta; Jáuregui, Olga
2009-04-01
An improved, quick and simple method for the extraction and quantification of the phytohormones (+)-abscisic acid (ABA) and its major glucose conjugate, abscisic acid glucose ester (ABA-GE) in plant samples is described. The method includes the addition of deuterium-labeled internal standards to the leaves at the beginning of the extraction for quantification, a simple extraction/centrifugation process and the injection into the liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS-MS) system in multiple reaction monitoring mode (MRM). Quality parameters of the method (detection limits, repeatability, reproducibility and linearity) have been studied. The objective of this work is to show the applicability of this method for quantifying the endogenous content of both ABA and ABA-GE in Cistus albidus plants that have been grown during an annual cycle under Mediterranean field conditions. Leaf samples from winter plants have low levels of ABA which increase in spring and summer showing two peaks that corresponded to April and August. These increases are coincident with the high temperature and solar radiation and the low RWC and RH registered along the year. On the other hand, the endogenous levels of ABA-GE increase until maximum values in July just before the ABA content reaches its highest concentration, decreasing in August and during autumn and winter. Our results suggest that the method is useful for quantifying both compounds in this plant material and represents the advantage of a short-time sample preparation with a high accuracy and viability.
Lee, Do-Hyun; Jang, Miran; Park, Je-Kyun
2014-10-01
By virtue of the biocompatibility and physical properties of hydrogel, picoliter-sized hydrogel microcapsules have been considered to be a biometric signature containing several features similar to that of encapsulated single cells, including phenotype, viability, and intracellular content. To maximize the experimental potential of encapsulating cells in hydrogel microcapsules, a method that enables efficient hydrogel microcapsule purification from oil is necessary. Current methods based on centrifugation for the conventional stepwise rinsing of oil, are slow and laborious and decrease the monodispersity and yield of the recovered hydrogel microcapsules. To remedy these shortcomings we have developed a simple one-step method to purify alginate microcapsules, containing a single live cell, from oil to aqueous phase. This method employs oil impregnation using a commercially available hydrophobic filter paper without multistep centrifugal purification and complicated microchannel networks. The oil-suspended alginate microcapsules encapsulating single cells from mammalian cancer cell lines (MCF-7, HepG2, and U937) and microorganisms (Chlorella vulgaris) were successfully exchanged to cell culture media by quick (~10 min) depletion of the surrounding oil phase without coalescence of neighboring microcapsules. Cell proliferation and high integrity of the microcapsules were also demonstrated by long-term incubation of microcapsules containing a single live cell. We expect that this method for the simple and rapid purification of encapsulated single-cell microcapsules will attain widespread adoption, assisting cell biologists and clinicians in the development of single-cell experiments. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Trelease, R B; Nieder, G L; Dørup, J; Hansen, M S
2000-04-15
Continuing evolution of computer-based multimedia technologies has produced QuickTime, a multiplatform digital media standard that is supported by stand-alone commercial programs and World Wide Web browsers. While its core functions might be most commonly employed for production and delivery of conventional video programs (e.g., lecture videos), additional QuickTime VR "virtual reality" features can be used to produce photorealistic, interactive "non-linear movies" of anatomical structures ranging in size from microscopic through gross anatomic. But what is really included in QuickTime VR and how can it be easily used to produce novel and innovative visualizations for education and research? This tutorial introduces the QuickTime multimedia environment, its QuickTime VR extensions, basic linear and non-linear digital video technologies, image acquisition, and other specialized QuickTime VR production methods. Four separate practical applications are presented for light and electron microscopy, dissectable preserved specimens, and explorable functional anatomy in magnetic resonance cinegrams.
Light scattering application for quantitative estimation of apoptosis
NASA Astrophysics Data System (ADS)
Bilyy, Rostyslav O.; Stoika, Rostyslav S.; Getman, Vasyl B.; Bilyi, Olexander I.
2004-05-01
Estimation of cell proliferation and apoptosis are in focus of instrumental methods used in modern biomedical sciences. Present study concerns monitoring of functional state of cells, specifically the development of their programmed death or apoptosis. The available methods for such purpose are either very expensive, or require time-consuming operations. Their specificity and sensitivity are frequently not sufficient for making conclusions which could be used in diagnostics or treatment monitoring. We propose a novel method for apoptosis measurement based on quantitative determination of cellular functional state taking into account their physical characteristics. This method uses the patented device -- laser microparticle analyser PRM-6 -- for analyzing light scattering by the microparticles, including cells. The method gives an opportunity for quick, quantitative, simple (without complicated preliminary cell processing) and relatively cheap measurement of apoptosis in cellular population. The elaborated method was used for studying apoptosis expression in murine leukemia cells of L1210 line and human lymphoblastic leukemia cells of K562 line. The results obtained by the proposed method permitted measuring cell number in tested sample, detecting and quantitative characterization of functional state of cells, particularly measuring the ratio of the apoptotic cells in suspension.
A method of batch-purifying microalgae with multiple antibiotics at extremely high concentrations
NASA Astrophysics Data System (ADS)
Han, Jichang; Wang, Song; Zhang, Lin; Yang, Guanpin; Zhao, Lu; Pan, Kehou
2016-01-01
Axenic microalgal strains are highly valued in diverse microalgal studies and applications. Antibiotics, alone or in combination, are often used to avoid bacterial contamination during microalgal isolation and culture. In our preliminary trials, we found that many microalgae ceased growing in antibiotics at extremely high concentrations but could resume growth quickly when returned to an antibiotics-free liquid medium and formed colonies when spread on a solid medium. We developed a simple and highly efficient method of obtaining axenic microalgal cultures based on this observation. First, microalgal strains of different species or strains were treated with a mixture of ampicillin, gentamycin sulfate, kanamycin, neomycin and streptomycin (each at a concentration of 600 mg/L) for 3 days; they were then transferred to antibiotics-free medium for 5 days; and finally they were spread on solid f/2 media to allow algal colonies to form. With this method, five strains of Nannochloropsis sp. (Eustigmatophyceae), two strains of Cylindrotheca sp. (Bacillariophyceae), two strains of Tetraselmis sp. (Chlorodendrophyceae) and one strain of Amphikrikos sp. (Trebouxiophyceae) were purified successfully. The method shows promise for batch-purifying microalgal cultures.
Rowe, David K; Parkyn, Stephanie; Quinn, John; Collier, Kevin; Hatton, Chris; Joy, Michael K; Maxted, John; Moore, Stephen
2009-06-01
A method was developed to score the ecological condition of first- to third-order stream reaches in the Auckland region of New Zealand based on the performance of their key ecological functions. Such a method is required by consultants and resource managers to quantify the reduction in ecological condition of a modified stream reach relative to its unmodified state. This is a fundamental precursor for the determination of fair environmental compensation for achieving no-net-loss in overall stream ecological value. Field testing and subsequent use of the method indicated that it provides a useful measure of ecological condition related to the performance of stream ecological functions. It is relatively simple to apply compared to a full ecological study, is quick to use, and allows identification of the degree of impairment of each of the key ecological functions. The scoring system was designed so that future improvements in the measurement of stream functions can be incorporated into it. Although the methodology was specifically designed for Auckland streams, the principles can be readily adapted to other regions and stream types.
Watershed-based segmentation of the corpus callosum in diffusion MRI
NASA Astrophysics Data System (ADS)
Freitas, Pedro; Rittner, Leticia; Appenzeller, Simone; Lapa, Aline; Lotufo, Roberto
2012-02-01
The corpus callosum (CC) is one of the most important white matter structures of the brain, interconnecting the two cerebral hemispheres, and is related to several neurodegenerative diseases. Since segmentation is usually the first step for studies in this structure, and manual volumetric segmentation is a very time-consuming task, it is important to have a robust automatic method for CC segmentation. We propose here an approach for fully automatic 3D segmentation of the CC in the magnetic resonance diffusion tensor images. The method uses the watershed transform and is performed on the fractional anisotropy (FA) map weighted by the projection of the principal eigenvector in the left-right direction. The section of the CC in the midsagittal slice is used as seed for the volumetric segmentation. Experiments with real diffusion MRI data showed that the proposed method is able to quickly segment the CC without any user intervention, with great results when compared to manual segmentation. Since it is simple, fast and does not require parameter settings, the proposed method is well suited for clinical applications.
Sun, Juan; Li, Weixi; Zhang, Yan; Hu, Xuexu; Wu, Li; Wang, Bujun
2016-01-01
A method based on the QuEChERS (quick, easy, cheap, effective, rugged, and safe) purification combined with ultrahigh performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS), was optimized for the simultaneous quantification of 25 mycotoxins in cereals. Samples were extracted with a solution containing 80% acetonitrile and 0.1% formic acid, and purified with QuEChERS before being separated by a C18 column. The mass spectrometry was conducted by using positive electrospray ionization (ESI+) and multiple reaction monitoring (MRM) models. The method gave good linear relations with regression coefficients ranging from 0.9950 to 0.9999. The detection limits ranged from 0.03 to 15.0 µg·kg−1, and the average recovery at three different concentrations ranged from 60.2% to 115.8%, with relative standard deviations (RSD%) varying from 0.7% to 19.6% for the 25 mycotoxins. The method is simple, rapid, accurate, and an improvement compared with the existing methods published so far. PMID:27983693
Wu, Yao-Dong; Zhou, Dong-Hui; Zhang, Long-Xian; Zheng, Wen-Bin; Ma, Jian-Gang; Wang, Meng; Zhu, Xing-Quan; Xu, Min-Jun
2016-09-01
Cryptosporidium is a widespread protozoan parasite that infects a large number of vertebrate animals, resulting in varying degrees of diarrhea or even death. As dairy cattle feces is an important source of Cryptosporidium spp. infection, development of a handy and accurate detection method via its oocysts in dairy cattle feces would be interesting and necessary. We herein developed a quick detecting method using recombinase polymerase amplification (RPA) combined with lateral flow (LF) strip to detect DNA of Cryptosporidium oocysts in dairy cattle feces. The DNA was released by boiled water with 0.1 % N-lauroylsarcosine sodium salt (LSS). The established method was proven to be of higher sensitivity than normal polymerase chain reaction (PCR) amplification with the lowest detection of 0.5 oocyst per reaction, and specificity with no cross reactivity to other common protozoan species in the intestine of dairy cattle. The diagnostic method established herein is simple, rapid, and cost-effective, and has potential for further development as a diagnostic kit for the diagnosis of cryptosporidiosis of dairy cattle.
Guidelines for preparing software user documentation
NASA Technical Reports Server (NTRS)
Miller, Diane F.
1987-01-01
Clear, easy-to-use software user's manuals make strong demands on special technical communication techniques. Principles and guidelines are given for analyzing the audience and dealing with wide-ranging backgrounds of potential users. Types of information to be included in a complete manual are suggested, with a technique for creating a user-oriented rather than process-oriented organization. Accuracy verification is emphasized. Simple tips are gievn for formatting for quick comprehension and reference, for deciding on packaging, for creating helpful illustrations and examples, and for setting up clear and consistent conventions. Simple guidelines are offered for writing clearly and concisely and for editing.
NASA Astrophysics Data System (ADS)
de Andrade, Rocelito Lopes; de Oliveira, Matheus Costa; Kohlrausch, Emerson Cristofer; Santos, Marcos José Leite
2018-05-01
This work presents a new and simple method for determining IPH (current source dependent on luminance), I0 (reverse saturation current), n (ideality factor), RP and RS, (parallel and series resistance) to build an electrical model for dye sensitized solar cells (DSSCs). The electrical circuit parameters used in the simulation and to generate theoretical curves for the single diode electrical model were extracted from I-V curves of assembled DSSCs. Model validation was performed by assembling five different types of DSSCs and evaluating the following parameters: effect of a TiO2 blocking/adhesive layer, thickness of the TiO2 layer and the presence of a light scattering layer. In addition, irradiance, temperature, series and parallel resistance, ideality factor and reverse saturation current were simulated.
Beam alignment based on two-dimensional power spectral density of a near-field image.
Wang, Shenzhen; Yuan, Qiang; Zeng, Fa; Zhang, Xin; Zhao, Junpu; Li, Kehong; Zhang, Xiaolu; Xue, Qiao; Yang, Ying; Dai, Wanjun; Zhou, Wei; Wang, Yuanchen; Zheng, Kuixing; Su, Jingqin; Hu, Dongxia; Zhu, Qihua
2017-10-30
Beam alignment is crucial to high-power laser facilities and is used to adjust the laser beams quickly and accurately to meet stringent requirements of pointing and centering. In this paper, a novel alignment method is presented, which employs data processing of the two-dimensional power spectral density (2D-PSD) for a near-field image and resolves the beam pointing error relative to the spatial filter pinhole directly. Combining this with a near-field fiducial mark, the operation of beam alignment is achieved. It is experimentally demonstrated that this scheme realizes a far-field alignment precision of approximately 3% of the pinhole size. This scheme adopts only one near-field camera to construct the alignment system, which provides a simple, efficient, and low-cost way to align lasers.
Direct reconstruction of dark energy.
Clarkson, Chris; Zunckel, Caroline
2010-05-28
An important issue in cosmology is reconstructing the effective dark energy equation of state directly from observations. With so few physically motivated models, future dark energy studies cannot only be based on constraining a dark energy parameter space. We present a new nonparametric method which can accurately reconstruct a wide variety of dark energy behavior with no prior assumptions about it. It is simple, quick and relatively accurate, and involves no expensive explorations of parameter space. The technique uses principal component analysis and a combination of information criteria to identify real features in the data, and tailors the fitting functions to pick up trends and smooth over noise. We find that we can constrain a large variety of w(z) models to within 10%-20% at redshifts z≲1 using just SNAP-quality data.
Relating the Stored Magnetic Energy of a Parallel-Plate Inductor to the Work of External Forces
ERIC Educational Resources Information Center
Gauthier, N.
2007-01-01
Idealized models are often used in introductory physics courses. For one, such models involve simple mathematics, which is a definite plus since complex mathematical manipulations quickly become an obstacle rather than a tool for a beginner. Idealized models facilitate a student's understanding and grasp of a given physical phenomenon, yet they…
Quick and Easy Classroom Makeover
ERIC Educational Resources Information Center
Adams, Caralee
2006-01-01
This article offers simple design ideas on classroom transformation that are easy on the pocketbook and will make the biggest difference to teachers and their students. These include: (1) Go with a splash of color; (2) Use bright fabrics; (3) Stick with blues and greens; (4) Use color to create nooks; (5) Buddy up with a shop class; (6) Hide the…
A Collar for Marking Big Game Animals
Robert L. Phillips
1970-01-01
A Simple, inexpensive collar made of Armor-tite (a vinyl-coated nylon fabric) was designed for marking white-tailed deer (Odocoileus virginianus) and moose (Alces alces). Field tests showed that the material is easily seen and extrememly durable. It may be suitable for use on other large mammals. The collar can be quickly fitted to individual animals under field...
The Harmonic Series Diverges Again and Again
ERIC Educational Resources Information Center
Kifowit, Steven J.; Stamps, Terra A.
2006-01-01
The harmonic series is one of the most celebrated infinite series of mathematics. A quick glance at a variety of modern calculus textbooks reveals that there are two very popular proofs of the divergence of the harmonic series. In this article, the authors survey these popular proofs along with many other proofs that are equally simple and…
Modeling Speed-Accuracy Tradeoff in Adaptive System for Practicing Estimation
ERIC Educational Resources Information Center
Nižnan, Juraj
2015-01-01
Estimation is useful in situations where an exact answer is not as important as a quick answer that is good enough. A web-based adaptive system for practicing estimates is currently being developed. We propose a simple model for estimating student's latent skill of estimation. This model combines a continuous measure of correctness and response…
LINUX, Virtualization, and the Cloud: A Hands-On Student Introductory Lab
ERIC Educational Resources Information Center
Serapiglia, Anthony
2013-01-01
Many students are entering Computer Science education with limited exposure to operating systems and applications other than those produced by Apple or Microsoft. This gap in familiarity with the Open Source community can quickly be bridged with a simple exercise that can also be used to strengthen two other important current computing concepts,…
School Bullying: Why Quick Fixes Do Not Prevent School Failure
ERIC Educational Resources Information Center
Casebeer, Cindy M.
2012-01-01
School bullying is a serious problem. It is associated with negative effects for bullies, targets, and bystanders. Bullying is related to school shootings, student suicides, and poor academic outcomes. Yet, this issue cannot be solved by way of simple, one-size-fits-all solutions. Instead, school bullying is a complex, systemic issue that requires…
ERIC Educational Resources Information Center
Kundey, Shannon M. A.; Strandell, Brittany; Mathis, Heather; Rowan, James D.
2010-01-01
(Hulse and Dorsky, 1977) and (Hulse and Dorsky, 1979) found that rats, like humans, learn sequences following a simple rule-based structure more quickly than those lacking a rule-based structure. Through two experiments, we explored whether two additional species--domesticated horses ("Equus callabus") and chickens ("Gallus domesticus")--would…
Airing Your Dirty Laundry: A Quick Marketable Pollution Permits Game for the Classroom
ERIC Educational Resources Information Center
Caviglia-Harris, Jill L.; Melstrom, Richard T.
2015-01-01
In this article, the authors describe a simple classroom game that demonstrates the advantage of tradable emissions permits in regulating environmental pollution. Students take on the role of polluters who must consider the costs of complying with a uniform reduction and a tradable permits program. The class is divided into high-cost polluters and…
Liu, Jing; Zhou, Yi-Xin
2003-09-01
This paper is aimed at investigating the roles of freezing dynamics of a liquid droplet to characterize the properties of the material. In particular, freezing curve-based monitoring was proposed to quickly evaluate the viability of biological materials subject to freezing, re-warming, or other kinds of injury, which is an extremely important issue in practices such as cryobiology, hyperthermia, or freshness evaluation of bio-samples. An integrated micro analysis device was fabricated which is simple in structure and cheap to make. Preliminary freezing results demonstrated that minor changes in a biological material due to freezing or warming injury might result in a significant deviation of its freezing curve from that of the intact biomaterials. Several potential thermal indexes to quantify the material features were pointed out. Further, experiments were performed on some freezing and thawing processes of small amount of water on a cooling surface to test the effects of droplet sizes, measurement sites, cooling strength, and cooling geometry, etc., on the freezing responses of a water droplet. Their implementation in developing a new micro analysis system were suggested. This freezing curve-based monitoring method may open a new strategy for the evaluation of biomaterials subject to destruction in diverse fields.
Using photoshop filters to create anatomic line-art medical images.
Kirsch, Jacobo; Geller, Brian S
2006-08-01
There are multiple ways to obtain anatomic drawings suitable for publication or presentations. This article demonstrates how to use Photoshop to alter digital radiologic images to create line-art illustrations in a quick and easy way. We present two simple to use methods; however, not every image can adequately be transformed and personal preferences and specific changes need to be applied to each image to obtain the desired result. There are multiple ways to obtain anatomic drawings suitable for publication or to prepare presentations. Medical illustrators have always played a major role in the radiology and medical education process. Whether used to teach a complex surgical or radiologic procedure, to define typical or atypical patterns of the spread of disease, or to illustrate normal or aberrant anatomy, medical illustration significantly affects learning (). However, if you are not an accomplished illustrator, the alternatives can be expensive (contacting a professional medical illustrator or buying an already existing stock of digital images) or simply not necessarily applicable to what you are trying to communicate. The purpose of this article is to demonstrate how using Photoshop (Adobe Systems, San Jose, CA) to alter digital radiologic images we can create line-art illustrations in a quick, inexpensive, and easy way in preparation for electronic presentations and publication.
Luo, Zhoufei; Lu, Jing; Li, Haipu; Tu, Yi; Wan, Yuehao; Yang, Zhaoguang
2018-09-15
A new, sensitive, and rapid method based on the Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) approach and air-assisted liquid-liquid microextraction (AALLME) technology was developed for the determination of 20 endocrine-disrupting compounds (EDCs) in fish by high-performance liquid chromatography-tandem mass spectrometry. The method first integrates AALLME into QuEChERS to achieve clean-up and enrichment of the EDCs in one step. A self-made glass tube was enfolded with plasticine to withstand the high centrifugal force. The established method was developed by optimization of the parameters. High linearities (R 2 > 0.9924) and recoveries (78.2-118.6%) at three spiked levels (5, 10, and 20 ng g -1 ), and low relative standard deviation values (1.1-14.5%) and limits of detection (0.03-0.80 ng g -1 ) were obtained. The method comparison shows that the proposed method is superior as it involves less organic solvent usage, simple operation and high efficiency. This method was successfully applied to different fishes for analyzing EDCs. Copyright © 2018 Elsevier Ltd. All rights reserved.
Hall, Richard J; Wang, Jing; Todd, Angela K; Bissielo, Ange B; Yen, Seiha; Strydom, Hugo; Moore, Nicole E; Ren, Xiaoyun; Huang, Q Sue; Carter, Philip E; Peacey, Matthew
2014-01-01
The discovery of new or divergent viruses using metagenomics and high-throughput sequencing has become more commonplace. The preparation of a sample is known to have an effect on the representation of virus sequences within the metagenomic dataset yet comparatively little attention has been given to this. Physical enrichment techniques are often applied to samples to increase the number of viral sequences and therefore enhance the probability of detection. With the exception of virus ecology studies, there is a paucity of information available to researchers on the type of sample preparation required for a viral metagenomic study that seeks to identify an aetiological virus in an animal or human diagnostic sample. A review of published virus discovery studies revealed the most commonly used enrichment methods, that were usually quick and simple to implement, namely low-speed centrifugation, filtration, nuclease-treatment (or combinations of these) which have been routinely used but often without justification. These were applied to a simple and well-characterised artificial sample composed of bacterial and human cells, as well as DNA (adenovirus) and RNA viruses (influenza A and human enterovirus), being either non-enveloped capsid or enveloped viruses. The effect of the enrichment method was assessed by both quantitative real-time PCR and metagenomic analysis that incorporated an amplification step. Reductions in the absolute quantities of bacteria and human cells were observed for each method as determined by qPCR, but the relative abundance of viral sequences in the metagenomic dataset remained largely unchanged. A 3-step method of centrifugation, filtration and nuclease-treatment showed the greatest increase in the proportion of viral sequences. This study provides a starting point for the selection of a purification method in future virus discovery studies, and highlights the need for more data to validate the effect of enrichment methods on different sample types, amplification, bioinformatics approaches and sequencing platforms. This study also highlights the potential risks that may attend selection of a virus enrichment method without any consideration for the sample type being investigated. Copyright © 2013 The Authors. Published by Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Kalscheuer, Thomas; Bastani, Mehrdad; Donohue, Shane; Persson, Lena; Aspmo Pfaffhuber, Andreas; Reiser, Fabienne; Ren, Zhengyong
2013-05-01
In many coastal areas of North America and Scandinavia, post-glacial clay sediments have emerged above sea level due to iso-static uplift. These clays are often destabilised by fresh water leaching and transformed to so-called quick clays as at the investigated area at Smørgrav, Norway. Slight mechanical disturbances of these materials may trigger landslides. Since the leaching increases the electrical resistivity of quick clay as compared to normal marine clay, the application of electromagnetic (EM) methods is of particular interest in the study of quick clay structures. For the first time, single and joint inversions of direct-current resistivity (DCR), radiomagnetotelluric (RMT) and controlled-source audiomagnetotelluric (CSAMT) data were applied to delineate a zone of quick clay. The resulting 2-D models of electrical resistivity correlate excellently with previously published data from a ground conductivity metre and resistivity logs from two resistivity cone penetration tests (RCPT) into marine clay and quick clay. The RCPT log into the central part of the quick clay identifies the electrical resistivity of the quick clay structure to lie between 10 and 80 Ω m. In combination with the 2-D inversion models, it becomes possible to delineate the vertical and horizontal extent of the quick clay zone. As compared to the inversions of single data sets, the joint inversion model exhibits sharper resistivity contrasts and its resistivity values are more characteristic of the expected geology. In our preferred joint inversion model, there is a clear demarcation between dry soil, marine clay, quick clay and bedrock, which consists of alum shale and limestone.
Method for estimating protein binding capacity of polymeric systems.
Sharma, Vaibhav; Blackwood, Keith A; Haddow, David; Hook, Lilian; Mason, Chris; Dye, Julian F; García-Gareta, Elena
2015-01-01
Composite biomaterials made from synthetic and protein-based polymers are extensively researched in tissue engineering. To successfully fabricate a protein-polymer composite, it is critical to understand how strongly the protein binds to the synthetic polymer, which occurs through protein adsorption. Currently, there is no cost-effective and simple method for characterizing this interfacial binding. To characterize this interfacial binding, we introduce a simple three-step method that involves: 1) synthetic polymer surface characterisation, 2) a quick, inexpensive and robust novel immuno-based assay that uses protein extraction compounds to characterize protein binding strength followed by 3) an in vitro 2D model of cell culture to confirm the results of the immuno-based assay. Fibrinogen, precursor of fibrin, was adsorbed (test protein) on three different polymeric surfaces: silicone, poly(acrylic acid)-coated silicone and poly(allylamine)-coated silicone. Polystyrene surface was used as a reference. Characterisation of the different surfaces revealed different chemistry and roughness. The novel immuno-based assay showed significantly stronger binding of fibrinogen to both poly(acrylic acid) and poly(allylamine) coated silicone. Finally, cell studies showed that the strength of the interaction between the protein and the polymer had an effect on cell growth. This novel immuno-based assay is a valuable tool in developing composite biomaterials of synthetic and protein-based polymers with the potential to be applied in other fields of research where protein adsorption onto surfaces plays an important role.
Rapid and simple method for in vivo ex utero development of mouse embryo explants.
Gonçalves, André B; Thorsteinsdóttir, Sólveig; Deries, Marianne
2016-01-01
The in utero development of mammals drastically reduces the accessibility of the mammalian embryo and therefore limits the range of experimental manipulation that can be done to study functions of genes or signaling pathways during embryo development. Over the past decades, tissue and organ-like culture methods have been developed with the intention of reproducing in vivo situations. Developing accessible and simple techniques to study and manipulate embryos is an everlasting challenge. Herein, we describe a reliable and quick technique to culture mid-gestation explanted mouse embryos on top of a floating membrane filter in a defined medium. Viability of the cultured tissues was assessed by apoptosis and proliferation analysis showing that cell proliferation is normal and there is only a slight increase in apoptosis after 12h of culture compared to embryos developing in utero. Moreover, differentiation and morphogenesis proceed normally as assessed by 3D imaging of the transformation of the myotome into deep back muscles. Not only does muscle cell differentiation occur as expected, but so do extracellular matrix organization and the characteristic splitting of the myotome into the three epaxial muscle groups. Our culture method allows for the culture and manipulation of mammalian embryo explants in a very efficient way, and it permits the manipulation of in vivo developmental events in a controlled environment. Explants grown under these ex utero conditions simulate real developmental events that occur in utero. Copyright © 2016 International Society of Differentiation. Published by Elsevier B.V. All rights reserved.
Disinfection methods in general practice and health authority clinics: a telephone survey
Farrow, S.C.; Kaul, S.; Littlepage, B.C.
1988-01-01
Concern about the epidemic of the acquired immune deficiency syndrome led to discussions in one health district about the dangers of cross-infection from instruments in general practice and health authority clinics. In order to establish what current disinfection practices were in use a telephone survey was adopted as a quick and easy method of data collection. Information was collected on who was responsible for disinfection as well as details of how each instrument was disinfected. Results from 69 general practices and 21 health authority clinice in one health district are reported. Some form of sterilizer was used in 63 general practices. These included water boilers (49%), dry heat sterilizers (41%), autoclaves (5%) and pressure cookers (5%). Sixty one practices were using metal vaginal specula and of these 29 were disinfecting by boiling, three were using pressure cookers, 18 dry heat, seven chemical methods, three autoclaves and one the central sterile department of the local hospital. Of those who were boiling after simple washing, three practices boiled for five to 10 minutes and reused instruments during the same clinic. Of the 29 using simple boiling 20 (69%) were boiling for less than 20 minutes. The study highlights the fact that no formal advice has been given on disinfection practice by the DHSS, the health authorities or the family practitioner committees. The need to set up local guidelines and develop practical steps for their introduction are discussed. PMID:3271009
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sen, A
Purpose: Accuboost treatment planning uses dwell times from a nomogram designed with Monte Carlo calculations for round and D-shaped applicators. A quick dose calculation method has been developed for verification of the HDR Brachytherapy dose as a second check. Methods: Accuboost breast treatment uses several round and D-shaped applicators to be used non-invasively with an Ir-192 source from a HDR Brachytherapy afterloader after the breast is compressed in a mammographic unit for localization. The breast thickness, source activity, the prescription dose and the applicator size are entered into a nomogram spreadsheet which gives the dwell times to be manually enteredmore » into the delivery computer. Approximating the HDR Ir-192 as a point source, and knowing the geometry of the round and D-applicators, the distances from the source positions to the midpoint of the central plane are calculated. Using the exposure constant of Ir-192 and medium as human tissue, the dose at a point is calculated as: D(cGy) = 1.254 × A × t/R2, where A is the activity in Ci, t is the dwell time in sec and R is the distance in cm. The dose from each dwell position is added to get the total dose. Results: Each fraction is delivered in two compressions: cranio-caudally and medial-laterally. A typical APBI treatment in 10 fractions requires 20 compressions. For a patient treated with D45 applicators and an average of 5.22 cm thickness, this calculation was 1.63 % higher than the prescription. For another patient using D53 applicators in the CC direction and 7 cm SDO applicators in the ML direction, this calculation was 1.31 % lower than the prescription. Conclusion: This is a simple and quick method to double check the dose on the central plane for Accuboost treatment.« less
Hou, Siyuan; Riley, Christopher B; Mitchell, Cynthia A; Shaw, R Anthony; Bryanton, Janet; Bigsby, Kathryn; McClure, J Trenton
2015-09-01
Immunoglobulin G (IgG) is crucial for the protection of the host from invasive pathogens. Due to its importance for human health, tools that enable the monitoring of IgG levels are highly desired. Consequently there is a need for methods to determine the IgG concentration that are simple, rapid, and inexpensive. This work explored the potential of attenuated total reflectance (ATR) infrared spectroscopy as a method to determine IgG concentrations in human serum samples. Venous blood samples were collected from adults and children, and from the umbilical cord of newborns. The serum was harvested and tested using ATR infrared spectroscopy. Partial least squares (PLS) regression provided the basis to develop the new analytical methods. Three PLS calibrations were determined: one for the combined set of the venous and umbilical cord serum samples, the second for only the umbilical cord samples, and the third for only the venous samples. The number of PLS factors was chosen by critical evaluation of Monte Carlo-based cross validation results. The predictive performance for each PLS calibration was evaluated using the Pearson correlation coefficient, scatter plot and Bland-Altman plot, and percent deviations for independent prediction sets. The repeatability was evaluated by standard deviation and relative standard deviation. The results showed that ATR infrared spectroscopy is potentially a simple, quick, and inexpensive method to measure IgG concentrations in human serum samples. The results also showed that it is possible to build a united calibration curve for the umbilical cord and the venous samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Feng, Junzong; Jiang, Yonggang; Liu, Ping; Zhang, Qiuhua; Wei, Ronghui; Chen, Xiang; Feng, Jian
2018-01-01
The conventional sol-gel method for preparing porous carbons is tedious and high-cost to prepare porous carbons and the control over the nanoporous architecture by solvents and carbonization is restricted. A simple and novel self-sacrificial salt templating method was first presented to adjust the microporous structure of porous carbon monoliths synthesized via the solvothermal method. Apart from good monolithic appearance, the solvothermal route allowed for ambient drying because it made sure that the polymerization reaction was completed quickly and thoroughly. The intact and crack-free porous carbon monoliths were investigated by scanning electron microscopy (SEM), thermogravimetric differential scanning calorimetry (TG-DSC), Fourier transform infrared (FT-IR), energy dispersive spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), X-ray diffraction (XRD) and nitrogen sorption measurements. It was proven that the self-sacrificial salts NH4SCN had been removed during pyrolyzing and so, porous carbon monoliths could be directly obtained after carbonization without the need of washing removal of salts. Most importantly, the microporous specific surface area of the resultant porous carbon monoliths was dramatically increased up to 770 m2/g and the Brunauer–Emmett–Teller (BET) specific surface area was up to 1131 m2/g. That was because the salts NH4SCN as self-sacrificial templating helped to form more around 0.6 nm, 0.72 nm and 1.1 nm micropores. The self-sacrificial salt templating is also a suitable and feasible method for controlling the nanoporous structure of other porous materials. PMID:29671818
SU-E-I-24: Method for CT Automatic Exposure Control Verification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gracia, M; Olasolo, J; Martin, M
Purpose: Design of a phantom and a simple method for the automatic exposure control (AEC) verification in CT. This verification is included in the computed tomography (CT) Spanish Quality Assurance Protocol. Methods: The phantom design is made from the head and the body phantom used for the CTDI measurement and PMMA plates (35×35 cm2) of 10 cm thickness. Thereby, three different thicknesses along the longitudinal axis are obtained which permit to evaluate the longitudinal AEC performance. Otherwise, the existent asymmetry in the PMMA layers helps to assess angular and 3D AEC operation.Recent acquisition in our hospital (August 2014) of Nomexmore » electrometer (PTW), together with the 10 cm pencil ionization chamber, led to register dose rate as a function of time. Measurements with this chamber fixed at 0° and 90° on the gantry where made on five multidetector-CTs from principal manufacturers. Results: Individual analysis of measurements shows dose rate variation as a function of phantom thickness. The comparative analysis shows that dose rate is kept constant in the head and neck phantom while the PMMA phantom exhibits an abrupt variation between both results, being greater results at 90° as the thickness of the phantom is 3.5 times larger than in the perpendicular direction. Conclusion: Proposed method is simple, quick and reproducible. Results obtained let a qualitative evaluation of the AEC and they are consistent with the expected behavior. A line of future development is to quantitatively study the intensity modulation and parameters of image quality, and a possible comparative study between different manufacturers.« less
Plug Your Users into Library Resources with OpenSearch Plug-Ins
ERIC Educational Resources Information Center
Baker, Nicholas C.
2007-01-01
To bring the library catalog and other online resources right into users' workspace quickly and easily without needing much more than a short XML file, the author, a reference and Web services librarian at Williams College, learned to build and use OpenSearch plug-ins. OpenSearch is a set of simple technologies and standards that allows the…
Real-time scheduling using minimum search
NASA Technical Reports Server (NTRS)
Tadepalli, Prasad; Joshi, Varad
1992-01-01
In this paper we consider a simple model of real-time scheduling. We present a real-time scheduling system called RTS which is based on Korf's Minimin algorithm. Experimental results show that the schedule quality initially improves with the amount of look-ahead search and tapers off quickly. So it sppears that reasonably good schedules can be produced with a relatively shallow search.
Drying hard maple (Acer saccharum L.) lumber in a small dehumidification kiln
Neal Bennett
2013-01-01
Portable sawmill owners quickly recognize the advantage to kiln drying lumber they produce. Having the ability to provide properly kiln-dried lumber opens new market opportunities and can increase profit margins. However, the construction and operation of a dry kiln must be economical and simple. A small dehumidification dry kiln constructed and tested in Princeton, WV...
ERIC Educational Resources Information Center
Brouwer, Henry
2005-01-01
A simple procedure to quickly screen different consumer products for the presence of lead, cadmium, and other metals is described. This screening technique avoids expending a lot of preparation time on samples known to contain low levels of hazardous metals where only samples testing positive for the desired elements need to be analyzed…
Description and prediction of individual tree biomass on pinon (Pinus edulis) in northern New Mexico
Mark Loveall; John T. Harrington
2008-01-01
The purpose of this study was to gain reliable information on the distribution of aboveground biomass of an important component of the woodlands of north-central New Mexico, and to develop prediction equations that may be used to quickly compute biomass from relatively simple field measurements. Improved understanding of and ability to predict aboveground biomass...
Detecting Faults In High-Voltage Transformers
NASA Technical Reports Server (NTRS)
Blow, Raymond K.
1988-01-01
Simple fixture quickly shows whether high-voltage transformer has excessive voids in dielectric materials and whether high-voltage lead wires too close to transformer case. Fixture is "go/no-go" indicator; corona appears if transformer contains such faults. Nests in wire mesh supported by cap of clear epoxy. If transformer has defects, blue glow of corona appears in mesh and is seen through cap.
Cerqueira, Maristela B R; Guilherme, Juliana R; Caldas, Sergiane S; Martins, Manoel L; Zanella, Renato; Primel, Ednei G
2014-07-01
A modified version of the QuEChERS method has been evaluated for the determination of 21 pharmaceuticals and 6 personal care products (PPCPs) in drinking-water sludge samples by employing ultra high liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The performance of the method was evaluated through linearity, recovery, precision (intra-day), method detection and quantification limits (MDL and MQL) and matrix effect. The calibration curves prepared in acetonitrile and in the matrix extract showed a correlation coefficient ranging from 0.98 to 0.99. MQLs values were on the ng g(-1) order of magnitude for most compounds. Recoveries between 50% and 93% were reached with RSDs lower than 10% for most compounds. Matrix effect was almost absent with values lower than 16% for 93% of the compounds. By coupling a quick and simple extraction called QuEChERS with the UPLC-MS/MS analysis, a method that is both selective and sensitive was obtained. This methodology was successfully applied to real samples and caffeine and benzophenone-3 were detected in ng g(-1) levels. Copyright © 2014 Elsevier Ltd. All rights reserved.
Multi Agent Reward Analysis for Learning in Noisy Domains
NASA Technical Reports Server (NTRS)
Tumer, Kagan; Agogino, Adrian K.
2005-01-01
In many multi agent learning problems, it is difficult to determine, a priori, the agent reward structure that will lead to good performance. This problem is particularly pronounced in continuous, noisy domains ill-suited to simple table backup schemes commonly used in TD(lambda)/Q-learning. In this paper, we present a new reward evaluation method that allows the tradeoff between coordination among the agents and the difficulty of the learning problem each agent faces to be visualized. This method is independent of the learning algorithm and is only a function of the problem domain and the agents reward structure. We then use this reward efficiency visualization method to determine an effective reward without performing extensive simulations. We test this method in both a static and a dynamic multi-rover learning domain where the agents have continuous state spaces and where their actions are noisy (e.g., the agents movement decisions are not always carried out properly). Our results show that in the more difficult dynamic domain, the reward efficiency visualization method provides a two order of magnitude speedup in selecting a good reward. Most importantly it allows one to quickly create and verify rewards tailored to the observational limitations of the domain.
NASA Astrophysics Data System (ADS)
Li, Yi; Abdel-Monem, Mohamed; Gopalakrishnan, Rahul; Berecibar, Maitane; Nanini-Maury, Elise; Omar, Noshin; van den Bossche, Peter; Van Mierlo, Joeri
2018-01-01
This paper proposes an advanced state of health (SoH) estimation method for high energy NMC lithium-ion batteries based on the incremental capacity (IC) analysis. IC curves are used due to their ability of detect and quantify battery degradation mechanism. A simple and robust smoothing method is proposed based on Gaussian filter to reduce the noise on IC curves, the signatures associated with battery ageing can therefore be accurately identified. A linear regression relationship is found between the battery capacity with the positions of features of interest (FOIs) on IC curves. Results show that the developed SoH estimation function from one single battery cell is able to evaluate the SoH of other batteries cycled under different cycling depth with less than 2.5% maximum errors, which proves the robustness of the proposed method on SoH estimation. With this technique, partial charging voltage curves can be used for SoH estimation and the testing time can be therefore largely reduced. This method shows great potential to be applied in reality, as it only requires static charging curves and can be easily implemented in battery management system (BMS).
Wang, Dan Ohtan; Matsuno, Hitomi; Ikeda, Shuji; Nakamura, Akiko; Yanagisawa, Hiroyuki; Hayashi, Yasunori; Okamoto, Akimitsu
2012-01-01
Fluorescence in situ hybridization (FISH) is a powerful tool used in karyotyping, cytogenotyping, cancer diagnosis, species specification, and gene-expression analysis. Although widely used, conventional FISH protocols are cumbersome and time consuming. We have now developed a FISH method using exciton-controlled hybridization-sensitive fluorescent oligodeoxynucleotide (ECHO) probes. ECHO–FISH uses a 25-min protocol from fixation to mounting that includes no stringency washing steps. We use ECHO–FISH to detect both specific DNA and RNA sequences with multicolor probes. ECHO–FISH is highly reproducible, stringent, and compatible with other fluorescent cellular labeling techniques. The resolution allows detection of intranuclear speckles of poly(A) RNA in HeLa cells and dissociated hippocampal primary cultures, and mRNAs in the distal dendrites of hippocampal neurons. We also demonstrate detection of telomeric and centromeric DNA on metaphase mouse chromosomes. The simplicity of the ECHO–FISH method will likely accelerate cytogenetic and gene-expression analysis with high resolution. PMID:22101241
Characterization and Separation of Cancer Cells with a Wicking Fiber Device.
Tabbaa, Suzanne M; Sharp, Julia L; Burg, Karen J L
2017-12-01
Current cancer diagnostic methods lack the ability to quickly, simply, efficiently, and inexpensively screen cancer cells from a mixed population of cancer and normal cells. Methods based on biomarkers are unreliable due to complexity of cancer cells, plasticity of markers, and lack of common tumorigenic markers. Diagnostics are time intensive, require multiple tests, and provide limited information. In this study, we developed a novel wicking fiber device that separates cancer and normal cell types. To the best of our knowledge, no previous work has used vertical wicking of cells through fibers to identify and isolate cancer cells. The device separated mouse mammary tumor cells from a cellular mixture containing normal mouse mammary cells. Further investigation showed the device separated and isolated human cancer cells from a heterogeneous mixture of normal and cancerous human cells. We report a simple, inexpensive, and rapid technique that has potential to identify and isolate cancer cells from large volumes of liquid samples that can be translated to on-site clinic diagnosis.
Girard, Jean-Michel; Deschênes, Jean-Sébastien; Tremblay, Réjean; Gagnon, Jonathan
2013-09-01
The objective of this work is to develop a quick and simple method for the in situ monitoring of sugars in biological cultures. A new technology based on Attenuated Total Reflectance-Fourier Transform Infrared (FT-IR/ATR) spectroscopy in combination with an external light guiding fiber probe was tested, first to build predictive models from solutions of pure sugars, and secondly to use those models to monitor the sugars in the complex culture medium of mixotrophic microalgae. Quantification results from the univariate model were correlated with the total dissolved solids content (R(2)=0.74). A vector normalized multivariate model was used to proportionally quantify the different sugars present in the complex culture medium and showed a predictive accuracy of >90% for sugars representing >20% of the total. This method offers an alternative to conventional sugar monitoring assays and could be used at-line or on-line in commercial scale production systems. Copyright © 2013 Elsevier Ltd. All rights reserved.
Analysis of bakery products by laser-induced breakdown spectroscopy.
Bilge, Gonca; Boyacı, İsmail Hakkı; Eseller, Kemal Efe; Tamer, Uğur; Çakır, Serhat
2015-08-15
In this study, we focused on the detection of Na in bakery products by using laser-induced breakdown spectroscopy (LIBS) as a quick and simple method. LIBS experiments were performed to examine the Na at 589 nm to quantify NaCl. A series of standard bread sample pellets containing various concentrations of NaCl (0.025-3.5%) were used to construct the calibration curves and to determine the detection limits of the measurements. Calibration graphs were drawn to indicate functions of NaCl and Na concentrations, which showed good linearity in the range of 0.025-3.5% NaCl and 0.01-1.4% Na concentrations with correlation coefficients (R(2)) values greater than 0.98 and 0.96. The obtained detection limits for NaCl and Na were 175 and 69 ppm, respectively. Performed experimental studies showed that LIBS is a convenient method for commercial bakery products to quantify NaCl concentrations as a rapid and in situ technique. Copyright © 2015 Elsevier Ltd. All rights reserved.
Immunofluorescence assay method to detect dengue virus in Paniai-Papua
NASA Astrophysics Data System (ADS)
Sucipto, Teguh Hari; Ahwanah, Nur Laila Fitriati; Churrotin, Siti; Matake, Norifumi; Kotaki, Tomohiro; Soegijanto, Soegeng
2016-03-01
The dengue viruses (DENV), which include in the family Flaviviridae and the genus Flavivirus, was endemic in tropical areas and had been transmitted to humans by Aedes aegypti. An increasing number of immigrants from endemic areas to the non-endemic areas have emphasized the need for a simple and reliable test for the diagnosis of dengue virus infection. The purpose of this study was to detect the dengue virus by immunofluorescence assay (IFA) in the general population at Paniai-Papua. The results obtained from this study had showed a significantly better discrimination for DENV specific IgG antibodies. A total of 158 samples, 116 samples were IgG antibodies positive and 42 samples were negative. The conclusion of this study, Papua is not only a malaria endemic area, but also dengue virus infections were detected by IFA method. Therefore, the IFA can be used as an important diagnostic tool, which is a quick and an easy way to test samples from immigrants who come to the non-endemic areas.
Park, Chan Woo; Moon, Yu Gyeong; Seong, Hyejeong; Jung, Soon Won; Oh, Ji-Young; Na, Bock Soon; Park, Nae-Man; Lee, Sang Seok; Im, Sung Gap; Koo, Jae Bon
2016-06-22
We demonstrate a new patterning technique for gallium-based liquid metals on flat substrates, which can provide both high pattern resolution (∼20 μm) and alignment precision as required for highly integrated circuits. In a very similar manner as in the patterning of solid metal films by photolithography and lift-off processes, the liquid metal layer painted over the whole substrate area can be selectively removed by dissolving the underlying photoresist layer, leaving behind robust liquid patterns as defined by the photolithography. This quick and simple method makes it possible to integrate fine-scale interconnects with preformed devices precisely, which is indispensable for realizing monolithically integrated stretchable circuits. As a way for constructing stretchable integrated circuits, we propose a hybrid configuration composed of rigid device regions and liquid interconnects, which is constructed on a rigid substrate first but highly stretchable after being transferred onto an elastomeric substrate. This new method can be useful in various applications requiring both high-resolution and precisely aligned patterning of gallium-based liquid metals.
Impulse Testing of Corporate-Fed Patch Array Antennas
NASA Technical Reports Server (NTRS)
Chamberlain, Neil F.
2011-01-01
This paper discusses a novel method for detecting faults in antenna arrays. The method, termed Impulse Testing, was developed for corporate-fed patch arrays where the element is fed by a probe and is shorted at its center. Impulse Testing was devised to supplement conventional microwave measurements in order to quickly verify antenna integrity. The technique relies on exciting each antenna element in turn with a fast pulse (or impulse) that propagates through the feed network to the output port of the antenna. The resulting impulse response is characteristic of the path through the feed network. Using an oscilloscope, a simple amplitude measurement can be made to detect faults. A circuit model of the antenna elements and feed network was constructed to assess various fault scenarios and determine fault-detection thresholds. The experimental setup and impulse measurements for two patch array antennas are presented. Advantages and limitations of the technique are discussed along with applications to other antenna array topologies
NASA Astrophysics Data System (ADS)
Jiao, Quanjun; Zhang, Xiao; Sun, Qi
2018-03-01
The availability of dense time series of Landsat images pro-vides a great chance to reconstruct forest disturbance and change history with high temporal resolution, medium spatial resolution and long period. This proposal aims to apply forest change detection method in Hainan Jianfengling Forest Park using yearly Landsat time-series images. A simple detection method from the dense time series Landsat NDVI images will be used to reconstruct forest change history (afforestation and deforestation). The mapping result showed a large decrease occurred in the extent of closed forest from 1980s to 1990s. From the beginning of the 21st century, we found an increase in forest areas with the implementation of forestry measures such as the prohibition of cutting and sealing in our study area. Our findings provide an effective approach for quickly detecting forest changes in tropical original forest, especially for afforestation and deforestation, and a comprehensive analysis tool for forest resource protection.
Automated discovery and construction of surface phase diagrams using machine learning
Ulissi, Zachary W.; Singh, Aayush R.; Tsai, Charlie; ...
2016-08-24
Surface phase diagrams are necessary for understanding surface chemistry in electrochemical catalysis, where a range of adsorbates and coverages exist at varying applied potentials. These diagrams are typically constructed using intuition, which risks missing complex coverages and configurations at potentials of interest. More accurate cluster expansion methods are often difficult to implement quickly for new surfaces. We adopt a machine learning approach to rectify both issues. Using a Gaussian process regression model, the free energy of all possible adsorbate coverages for surfaces is predicted for a finite number of adsorption sites. Our result demonstrates a rational, simple, and systematic approachmore » for generating accurate free-energy diagrams with reduced computational resources. Finally, the Pourbaix diagram for the IrO 2(110) surface (with nine coverages from fully hydrogenated to fully oxygenated surfaces) is reconstructed using just 20 electronic structure relaxations, compared to approximately 90 using typical search methods. Similar efficiency is demonstrated for the MoS 2 surface.« less
Toluidine blue: rapid and simple malaria parasite screening and species identification.
Awale, Rupali; Maji, Ratnaprabha; Patil, Parag; Lingiah, Raghavendra; Mukhopadhyay, Ashok Kumar; Sharma, Subhadra
2017-01-01
Malaria, a febrile illness mostly confined to the tropical countries is transmitted by bite of infected female Anopheles mosquito. In 2015 alone, 88% of the malaria burden and 90% deaths due to malaria were confined to the African and Asian countries. Although number of tests are available for rapid diagnosis and screening for malaria, peripheral blood smear examination remains the gold standard. Leishman stain is recommended by WHO however herein we evaluate one of the alternative methods of staining which is simple and rapid. Fifty patients attending the various outpatient departments of the tertiary care hospital with fever and suspected to have malaria were selected. Two thin-air dried smears prepared from the peripheral venous blood from these subjects were stained by Leishman and Toluidine blue method. The findings of the slides by two independent qualified professionals were noted and the results were analyzed. A total of 14% (7/50) cases were diagnosed to have malaria. All the malaria cases which were positive in Leishman stain were also detected in Toluidine blue stain. Malarial parasites were clearly visible against the homogenously light green background in Toluidine blue. The detection of malarial parasite by Toluidine blue was quick, easy and confirmative. Toluidine blue stained peripheral blood smear allows for easy identification and speciation of malarial parasite at low magnification and in shorter period of time.
The noisy edge of traveling waves
Hallatschek, Oskar
2011-01-01
Traveling waves are ubiquitous in nature and control the speed of many important dynamical processes, including chemical reactions, epidemic outbreaks, and biological evolution. Despite their fundamental role in complex systems, traveling waves remain elusive because they are often dominated by rare fluctuations in the wave tip, which have defied any rigorous analysis so far. Here, we show that by adjusting nonlinear model details, noisy traveling waves can be solved exactly. The moment equations of these tuned models are closed and have a simple analytical structure resembling the deterministic approximation supplemented by a nonlocal cutoff term. The peculiar form of the cutoff shapes the noisy edge of traveling waves and is critical for the correct prediction of the wave speed and its fluctuations. Our approach is illustrated and benchmarked using the example of fitness waves arising in simple models of microbial evolution, which are highly sensitive to number fluctuations. We demonstrate explicitly how these models can be tuned to account for finite population sizes and determine how quickly populations adapt as a function of population size and mutation rates. More generally, our method is shown to apply to a broad class of models, in which number fluctuations are generated by branching processes. Because of this versatility, the method of model tuning may serve as a promising route toward unraveling universal properties of complex discrete particle systems. PMID:21187435
Kharade, Pankaj; Banerjee, Ardhendu; Gupta, Tapas
2012-01-01
A diagnostic radiograph of the posterior regions of the jaws is mandatory if implant placement is considered at these sites. The goal is to avoid damage to important anatomical structures such as the inferior alveolar canal and maxillary sinus. Using radiographs to evaluate the remaining bone height available for implant insertion is a common procedure. Many articles have evaluated the success rates of fixed prostheses supported by osseointegrated implants, indicating high rates of success for prostheses 5-10 years in function. However, if an orthopantomogram machine is not readily available, periapical radiographs can be used for vertical bone height assessment. The familiar procedure of incorporating a metal ball of known diameter into an acrylic template is the method of choice. This is a relatively tedious and expensive procedure involving multiple steps, including impression taking, creation of a study model, and manufacture of a metal ball-bearing acrylic template. A further disadvantage for the patient is that a diagnostic radiograph can be taken only at the next appointment. This paper describes a quick and simple method to obtain a radiographic evaluation of remaining alveolar bone height and soft tissue thickness prior to implant placement with help of a metal ball device to avoid template fabrication and time consumption. Soft tissue thickness is measured nonsurgically.
Analysis of radon and thoron progeny measurements based on air filtration.
Stajic, J M; Nikezic, D
2015-02-01
Measuring of radon and thoron progeny concentrations in air, based on air filtration, was analysed in order to assess the reliability of the method. Changes of radon and thoron progeny activities on the filter during and after air sampling were investigated. Simulation experiments were performed involving realistic measuring parameters. The sensitivity of results (radon and thoron concentrations in air) to the variations of alpha counting in three and five intervals was studied. The concentration of (218)Po showed up to be the most sensitive to these changes, as was expected because of its short half-life. The well-known method for measuring of progeny concentrations based on air filtration is rather unreliable and obtaining unrealistic or incorrect results appears to be quite possible. A simple method for quick estimation of radon potential alpha energy concentration (PAEC), based on measurements of alpha activity in a saturation regime, was proposed. Thoron PAEC can be determined from the saturation activity on the filter, through beta or alpha measurements. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
The enhancement of friction ridge detail on brass ammunition casings using cold patination fluid.
James, Richard Michael; Altamimi, Mohamad Jamal
2015-12-01
Brass ammunition is commonly found at firearms related crime scenes. For this reason, many studies have focused on evidence that can be obtained from brass ammunition such as DNA, gunshot residue and fingerprints. Latent fingerprints on ammunition can provide good forensic evidence, however; fingerprint development on ammunition casings has proven to be difficult. A method using cold patination fluid is described as a potential tool to enhance friction ridge detail on brass ammunition casings. Current latent fingerprint development methods for brass ammunition have either failed to provide the necessary quality of friction ridge detail or can be very time consuming and require expensive equipment. In this study, the enhancement of fingerprints on live ammunition has been achieved with a good level of detail whilst the development on spent casings has to an extent also been possible. Development with cold patination fluid has proven to be a quick, simple and cost-effective method for fingerprint development on brass ammunition that can be easily implemented for routine police work. Crown Copyright © 2015. Published by Elsevier Ireland Ltd. All rights reserved.
An induced current method for measuring zeta potential of electrolyte solution-air interface.
Song, Yongxin; Zhao, Kai; Wang, Junsheng; Wu, Xudong; Pan, Xinxiang; Sun, Yeqing; Li, Dongqing
2014-02-15
This paper reports a novel and very simple method for measuring the zeta potential of electrolyte solution-air interface. When a measuring electrode contacts the electrolyte solution-air interface, an electrical current will be generated due to the potential difference between the electrode-air surface and the electrolyte solution-air interface. The amplitude of the measured electric signal is linearly proportional to this potential difference; and depends only on the zeta potential at the electrolyte solution-air interface, regardless of the types and concentrations of the electrolyte. A correlation between the zeta potential and the measured voltage signal is obtained based on the experimental data. Using this equation, the zeta potential of any electrolyte solution-air interface can be evaluated quickly and easily by inserting an electrode through the electrolyte solution-air interface and measuring the electrical signal amplitude. This method was verified by comparing the obtained results of NaCl, MgCl2 and CaCl2 solutions of different pH values and concentrations with the zeta potential data reported in the published journal papers. Copyright © 2013 Elsevier Inc. All rights reserved.
Initial experience with hysteroscopic tubal occlusion (Essure®)
Depes, Daniella De Batista; Pereira, Ana Maria Gomes; Lippi, Umberto Gazi; Martins, João Alfredo; Lopes, Reginaldo Guedes Coelho
2016-01-01
ABSTRACT Objective To evaluate results of early tubal occlusions performed by hysteroscopy (Essure®). Methods This prospective study included 38 patients, 73.7% of them were white, mean age 34.5 years, they have had on average 3 pregnancies and 2.7 of deliveries. A total of 86.8% of patients previously prepared the endometrium. All procedures were carried out at outpatient unit without anesthesia. Results Insertion rate of the device was 100% at a mean time of 4 minutes and 50 seconds. Based on the analogical visual scale, average pain reported was three, and 55.3% of women did not report pain after the procedure. After 3 months, 89.5% of patients were very satisfied with the method. Simple radiographs of the pelvis showed 92.1% of topical devices, and one case of unilateral expulsion had occurred. A four years follow-up did not show failure in the method. Conclusions Tubal occlusion through hysteroscopy at outpatient unit and without anesthesia was a quickly and well-tolerated procedure. No serious complications were seen, the success rate was high, and patients were satisfied. PMID:27462885
Malhat, Farag; Boulangé, Julien; Abdelraheem, Ehab; Abd Allah, Osama; Abd El-Hamid, Rania; Abd El-Salam, Shokr
2017-08-15
A simple and rapid gas chromatography with flame photometric detector (GC-FPD) determination method was developed to detect residue levels and investigate the dissipation pattern and safe use of fenitrothion in tomatoes. A modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) using an ethyl acetate-based extraction, followed by a dispersive solid-phase extraction (d-SPE) with primary-secondary amine (PSA) and graphite carbon black (GCB) for clean up, was applied prior to GC-FPD analysis. The method showed satisfactory linearity, recovery and precision. The limits of detection (LOD) and quantification (LOQ) were 0.005 and 0.01mg/kg, respectively. The residue levels of fenitrothion were best described by first order kinetics with a half-life of 2.2days in tomatoes. The potential health risks posed by fenitrothion were not significant, based on supervised residue trial data. The current findings could provide guidance for safe and reasonable use of fenitrothion in tomatoes and prevent health problems to consumers. Copyright © 2017 Elsevier Ltd. All rights reserved.
Tagiri-Endo, Misako; Suzuki, Shigeru; Nakamura, Tomoyuki; Hatakeyama, Takashi; Kawamukai, Kazuo
2009-02-01
A simple and quick online solid-phase extraction (SPE) coupled to liquid chromatography (LC)/tandem mass spectrometry (MS/MS) for the determination of the five antibiotics (florfenicol, FF; lincomycin, LCM; oxytetracyclin, OTC; tylosin, TS; valnemulin, VLM) in swine wastewater has been developed. After filtration, aliquots (100 microl) of wastewater samples were directly injected to a column-switching LC system. Some matrix interference was removed by washing up SPE column with 0.2% formic acid solution and acetonitrile. Antibiotics eluted from SPE column were separated on analytical column by converting switching valve and were detected by MS/MS. Calibration curves using the method of standard addition had very good correlation coefficients (r > 0.99) in the range of 0.1 to 2 ng/ml. The intra-day precision of the method was less than 12% and the inter-day precision was between 6 to 17%. The detection limits were 0.01-0.1 ng/ml. When this method was applied to wastewater samples in swine facilities, four compounds (LCM, OTC, TS, and VLM) were detected.
Functional programming interpreter. M. S. thesis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robison, A.D.
1987-03-01
Functional Programming (FP) sup BAC87 is an alternative to conventional imperative programming languages. This thesis describes an FP interpreter implementation. Superficially, FP appears to be a simple, but very inefficient language. Its simplicity, however, allows it to be interpreted quickly. Much of the inefficiency can be removed by simple interpreter techniques. This thesis describes the Illinois Functional Programming (IFP) interpreter, an interactive functional programming implementation which runs under both MS-DOS and UNIX. The IFP interpreter allows functions to be created, executed, and debugged in an environment very similar to UNIX. IFP's speed is competitive with other interpreted languages such asmore » BASIC.« less
Biotool2Web: creating simple Web interfaces for bioinformatics applications.
Shahid, Mohammad; Alam, Intikhab; Fuellen, Georg
2006-01-01
Currently there are many bioinformatics applications being developed, but there is no easy way to publish them on the World Wide Web. We have developed a Perl script, called Biotool2Web, which makes the task of creating web interfaces for simple ('home-made') bioinformatics applications quick and easy. Biotool2Web uses an XML document containing the parameters to run the tool on the Web, and generates the corresponding HTML and common gateway interface (CGI) files ready to be published on a web server. This tool is available for download at URL http://www.uni-muenster.de/Bioinformatics/services/biotool2web/ Georg Fuellen (fuellen@alum.mit.edu).
Development of a simple, self-contained flight test data acquisition system
NASA Technical Reports Server (NTRS)
Clarke, R.; Shane, D.; Roskam, J.; Rummer, D. I.
1982-01-01
The flight test system described combines state-of-the-art microprocessor technology and high accuracy instrumentation with parameter identification technology which minimize data and flight time requirements. The system was designed to avoid permanent modifications of the test airplane and allow quick installation. It is capable of longitudinal and lateral-directional stability and control derivative estimation. Details of this system, calibration and flight test procedures, and the results of the Cessna 172 flight test program are presented. The system proved easy to install, simple to operate, and capable of accurate estimation of stability and control parameters in the Cessna 172 flight tests.
NASA Astrophysics Data System (ADS)
Yao, Tongjie; Cui, Tieyu; Wang, Hao; Xu, Linxu; Cui, Fang; Wu, Jie
2014-06-01
Metal nanoparticles are promising catalysts for dye degradation in treating wastewater despite the challenges of recycling and stability. In this study, we have introduced a simple way to prepare Au@polypyrrole (PPy)/Fe3O4 catalysts with Au nanoparticles embedded in a PPy/Fe3O4 capsule shell. The PPy/Fe3O4 capsule shell used as a support was constructed in one-step, which not only dramatically simplified the preparation process, but also easily controlled the magnetic properties of the catalysts through adjusting the dosage of FeCl2.4H2O. The component Au nanoparticles could catalyze the reduction of methylene blue dye with NaBH4 as a reducing agent and the reaction rate constant was calculated through the pseudo-first-order reaction equation. The Fe3O4 nanoparticles permitted quick recycling of the catalysts with a magnet due to their room-temperature superparamagnetic properties; therefore, the catalysts exhibited good reusability. In addition to catalytic activity and reusability, stability is also an important property for catalysts. Because both Au and Fe3O4 nanoparticles were wrapped in the PPy shell, compared with precursor polystyrene/Au composites and bare Fe3O4 nanoparticles, the stability of Au@PPy/Fe3O4 hollow capsules was greatly enhanced. Since the current method is simple and flexible to create recyclable catalysts with high stability, it would promote the practicability of metal nanoparticle catalysts in industrial polluted water treatment.Metal nanoparticles are promising catalysts for dye degradation in treating wastewater despite the challenges of recycling and stability. In this study, we have introduced a simple way to prepare Au@polypyrrole (PPy)/Fe3O4 catalysts with Au nanoparticles embedded in a PPy/Fe3O4 capsule shell. The PPy/Fe3O4 capsule shell used as a support was constructed in one-step, which not only dramatically simplified the preparation process, but also easily controlled the magnetic properties of the catalysts through adjusting the dosage of FeCl2.4H2O. The component Au nanoparticles could catalyze the reduction of methylene blue dye with NaBH4 as a reducing agent and the reaction rate constant was calculated through the pseudo-first-order reaction equation. The Fe3O4 nanoparticles permitted quick recycling of the catalysts with a magnet due to their room-temperature superparamagnetic properties; therefore, the catalysts exhibited good reusability. In addition to catalytic activity and reusability, stability is also an important property for catalysts. Because both Au and Fe3O4 nanoparticles were wrapped in the PPy shell, compared with precursor polystyrene/Au composites and bare Fe3O4 nanoparticles, the stability of Au@PPy/Fe3O4 hollow capsules was greatly enhanced. Since the current method is simple and flexible to create recyclable catalysts with high stability, it would promote the practicability of metal nanoparticle catalysts in industrial polluted water treatment. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr00023d
Momose, Naoki; Yamakoshi, Rie; Kokubo, Ryo; Yasuda, Toru; Iwamoto, Norio; Umeda, Chinori; Nakajima, Itsuro; Yanagisawa, Mitsunobu; Tomizawa, Yasuko
2010-03-01
We developed a simple device that stabilizes the blood level in the reservoir of the extracorporeal circulation open circuit system by measuring the hydrostatic pressure of the reservoir to control the flow rate of the arterial pump. When the flow rate of the venous return decreases, the rotation speed of the arterial pump is automatically slowed down. Consequently, the blood level in the reservoir is stabilized quickly between two arbitrarily set levels and never falls below the pre-set low level. We conducted a basic experiment to verify the operation of the device, using a mock circuit with water. Commercially available pumps and reservoir were used without modification. The results confirmed that the control method effectively regulates the reservoir liquid level and is highly reliable. The device possibly also functions as a safety device.
Rapid Design of Gravity Assist Trajectories
NASA Technical Reports Server (NTRS)
Carrico, J.; Hooper, H. L.; Roszman, L.; Gramling, C.
1991-01-01
Several International Solar Terrestrial Physics (ISTP) missions require the design of complex gravity assisted trajectories in order to investigate the interaction of the solar wind with the Earth's magnetic field. These trajectories present a formidable trajectory design and optimization problem. The philosophy and methodology that enable an analyst to design and analyse such trajectories are discussed. The so called 'floating end point' targeting, which allows the inherently nonlinear multiple body problem to be solved with simple linear techniques, is described. The combination of floating end point targeting with analytic approximations with a Newton method targeter to achieve trajectory design goals quickly, even for the very sensitive double lunar swingby trajectories used by the ISTP missions, is demonstrated. A multiconic orbit integration scheme allows fast and accurate orbit propagation. A prototype software tool, Swingby, built for trajectory design and launch window analysis, is described.
NASA Technical Reports Server (NTRS)
Allison, D. O.
1972-01-01
Computer programs for flow fields around planetary entry vehicles require real-gas equilibrium thermodynamic properties in a simple form which can be evaluated quickly. To fill this need, polynomial approximations were found for thermodynamic properties of air and model planetary atmospheres. A coefficient-averaging technique was used for curve fitting in lieu of the usual least-squares method. The polynomials consist of terms up to the ninth degree in each of two variables (essentially pressure and density) including all cross terms. Four of these polynomials can be joined to cover, for example, a range of about 1000 to 11000 K and 0.00001 to 1 atmosphere (1 atm = 1.0133 x 100,000 N/m sq) for a given thermodynamic property. Relative errors of less than 1 percent are found over most of the applicable range.
Multifunctional PMMA@Fe3O4@DR Magnetic Materials for Efficient Adsorption of Dyes
Yu, Bing; He, Liang; Wang, Yifan
2017-01-01
Magnetic porous microspheres are widely used in modern wastewater treatment technology due to their simple and quick dye adsorption and separation functions. In this article, we prepared porous polymethylmethacrylate (PMMA) microspheres by the seed-swelling method, followed by in situ formation of iron oxide (Fe3O4) nanoparticles within the pore. Then, we used diazo-resin (DR) to encapsulate the porous magnetic microspheres and achieve PMMA@Fe3O4@DR magnetic material. We studied the different properties of magnetic microspheres by different dye adsorption experiments before and after the encapsulation and demonstrated that the PMMA@Fe3O4@DR microspheres can be successfully used as a reusable absorbent for fast and easy removal of anionic and aromatic dyes from wastewater and can maintain excellent magnetic and adsorption properties in harsh environments. PMID:29077025
Capi text V.1--data analysis software for nailfold skin capillaroscopy.
Dobrev, Hristo P
2007-01-01
Nailfold skin capillaroscopy is a simple non-invasive method used to assess conditions of disturbed microcirculation such as Raynaud's phenomenon, acrocyanosis, perniones, connective tissue diseases, psoriasis, diabetes mellitus, neuropathy and vibration disease. To develop data analysis software aimed at assisting the documentation and analysis of a capillaroscopic investigation. SOFTWARE DESCRIPTION: The programme is based on a modular principle. The module "Nomenclatures" includes menus for the patients' data. The module "Examinations" includes menus for all general and specific aspects of the medical examination and capillaroscopic investigations. The modules "Settings" and "Information" include customization menus for the programme. The results of nailfold capillaroscopy can be printed in a short or expanded form. This software allows physicians to perform quick search by using various specified criteria and prepare analyses and reports. This software programme will facilitate any practitioner who performs nailfold skin capillaroscopy.
FLaapLUC: A pipeline for the generation of prompt alerts on transient Fermi-LAT γ-ray sources
NASA Astrophysics Data System (ADS)
Lenain, J.-P.
2018-01-01
The large majority of high energy sources detected with Fermi-LAT are blazars, which are known to be very variable sources. High cadence long-term monitoring simultaneously at different wavelengths being prohibitive, the study of their transient activities can help shedding light on our understanding of these objects. The early detection of such potentially fast transient events is the key for triggering follow-up observations at other wavelengths. A Python tool, FLaapLUC, built on top of the Science Tools provided by the Fermi Science Support Center and the Fermi-LAT collaboration, has been developed using a simple aperture photometry approach. This tool can effectively detect relative flux variations in a set of predefined sources and alert potential users. Such alerts can then be used to trigger target of opportunity observations with other facilities. It is shown that FLaapLUC is an efficient tool to reveal transient events in Fermi-LAT data, providing quick results which can be used to promptly organise follow-up observations. Results from this simple aperture photometry method are also compared to full likelihood analyses. The FLaapLUC package is made available on GitHub and is open to contributions by the community.
Detection of radiation treatment of beans using DNA comet assay
NASA Astrophysics Data System (ADS)
Khan, Ashfaq A.; Khan, Hasan M.; Delincée, Henry
2002-03-01
A simple technique of microgel electrophoresis of single cells (DNA Comet Assay) enabled a quick detection of radiation treatment of several kinds of leguminous beans (azuki, black, black eye, mung, pinto, red kidney and white beans). Each variety was exposed to radiation doses of 0.5, 1 and 5kGy covering the permissible limits for insect disinfestation. The cells or nuclei from beans were extracted in cold PBS, embedded in agarose on microscope slides, lysed between 15 and 60min in 2.5% SDS and electrophoresis was carried out at a voltage of 2V/cm for 2-2.5min. After silver staining, the slides were evaluated through an ordinary transmission microscope. In irradiated samples, fragmented DNA stretched towards the anode and the damaged cells appeared as a comet. The density of DNA in the tails increased with increasing radiation dose. However, in non-irradiated samples, the large molecules of DNA remained relatively intact and there was only minor or no migration of DNA; the cells were round or had very short tails only. Hence, the DNA comet assay provides an inexpensive, rapid and relatively simple screening method for the detection of irradiated beans.
A simple method for finding the scattering coefficients of quantum graphs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cottrell, Seth S.
2015-09-15
Quantum walks are roughly analogous to classical random walks, and similar to classical walks they have been used to find new (quantum) algorithms. When studying the behavior of large graphs or combinations of graphs, it is useful to find the response of a subgraph to signals of different frequencies. In doing so, we can replace an entire subgraph with a single vertex with variable scattering coefficients. In this paper, a simple technique for quickly finding the scattering coefficients of any discrete-time quantum graph will be presented. These scattering coefficients can be expressed entirely in terms of the characteristic polynomial ofmore » the graph’s time step operator. This is a marked improvement over previous techniques which have traditionally required finding eigenstates for a given eigenvalue, which is far more computationally costly. With the scattering coefficients we can easily derive the “impulse response” which is the key to predicting the response of a graph to any signal. This gives us a powerful set of tools for rapidly understanding the behavior of graphs or for reducing a large graph into its constituent subgraphs regardless of how they are connected.« less
Barbés, Benigno; Azcona, Juan Diego; Prieto, Elena; de Foronda, José Manuel; García, Marina; Burguete, Javier
2015-09-08
A simple and independent system to detect and measure the position of a number of points in space was devised and implemented. Its application aimed to detect patient motion during radiotherapy treatments, alert of out-of-tolerances motion, and record the trajectories for subsequent studies. The system obtains the 3D position of points in space, through its projections in 2D images recorded by two cameras. It tracks black dots on a white sticker placed on the surface of the moving object. The system was tested with linear displacements of a phantom, circular trajectories of a rotating disk, oscillations of an in-house phantom, and oscillations of a 4D phantom. It was also used to track 461 trajectories of points on the surface of patients during their radiotherapy treatments. Trajectories of several points were reproduced with accuracy better than 0.3 mm in the three spatial directions. The system was able to follow periodic motion with amplitudes lower than 0.5 mm, to follow trajectories of rotating points at speeds up to 11.5 cm/s, and to track accurately the motion of a respiratory phantom. The technique has been used to track the motion of patients during radiotherapy and to analyze that motion. The method is flexible. Its installation and calibration are simple and quick. It is easy to use and can be implemented at a very affordable price. Data collection does not involve any discomfort to the patient and does not delay the treatment, so the system can be used routinely in all treatments. It has an accuracy similar to that of other, more sophisticated, commercially available systems. It is suitable to implement a gating system or any other application requiring motion detection, such as 4D CT, MRI or PET.
Psychological first-aid: a practical aide-memoire.
Leach, J
1995-07-01
Despite advances made in recent years in medical first aid, psychiatric intervention, survival training and equipment design, many people still perish quickly during and immediately following a disastrous event. In this study, individuals and groups of survivors of life-threatening events were debriefed and the behavior of those who coped well during such a threat to life were compared with those who did not. The behaviors of those who coped well were distilled into a set of principles for psychological first aid; that is, a series of simple actions for use within a disaster which serves to recover victims to functional behavior as quickly as possible, thus increasing their chance for survival. These principles of psychological first aid have recently been introduced into basic first aid and survival training courses for both military and civilian units.
Sterilisation in the laboratory autoclave using direct air displacement by steam.
Everall, P H; Morris, C A; Yarnell, R
1978-01-01
A device using a steam injection funnel is described by means of which air can be driven quickly and surely from an autoclave load. It is simple and inexpensive, necessitates no changes in the working routine of a microbiology laboratory, and does not interfere with the operation of the autoclave in its normal mode. Images Fig. 1 Fig. 3 PMID:344345
Waves on the Fly--Encouraging Inquiry in the Physics Classroom
ERIC Educational Resources Information Center
Cottam, Michael
2006-01-01
In this article, the author shares a very successful 50-minute inquiry-based physics lesson that uses only small metal cans, a bit of string, and the inquiring minds of middle schoolers. The topic of the lesson is wave motion and energy transfer. The intent of this article is to show that tests of student-generated hypotheses can be simple, quick,…
Fire Makers, Barnyards, and Prickly Forests: A Preschool Stroll around the Block
ERIC Educational Resources Information Center
Bentley, Dana Frantz
2012-01-01
The daily trips outside can be challenging, and living in Manhattan makes them even more complex. It seems there is no such thing as a simple stroll, or a quick trip outside; and the winter weather makes such excursions that much more complex. Yet, it is always worth it. In the author's nine years of teaching, she has discovered that a "quick…
Performance Assessment of the Masses in 30 Seconds or Less
ERIC Educational Resources Information Center
Dunbar, Laura
2012-01-01
Performance assessment does not have to be a time-consuming ordeal; it is a great way to assess our students' skills. It is essential to create a rubric that is simple, quick, and objective. This article discusses the process of creating a rubric as well as showing a rubric used by the author in her general music classroom for several years.…
Cyclic Fatigue of Brittle Materials with an Indentation-Induced Flaw System
NASA Technical Reports Server (NTRS)
Choi, Sung R.; Salem, Jonathan A.
1996-01-01
The ratio of static to cyclic fatigue life, or 'h ratio', was obtained numerically for an indentation flaw system subjected to sinusoidal loading conditions. Emphasis was placed on developing a simple, quick lifetime prediction tool. The solution for the h ratio was compared with experimental static and cyclic fatigue data obtained from as-indented 96 wt.% alumina specimens tested in room-temperature distilled water.
GIS Based System for Post-Earthquake Crisis Managment Using Cellular Network
NASA Astrophysics Data System (ADS)
Raeesi, M.; Sadeghi-Niaraki, A.
2013-09-01
Earthquakes are among the most destructive natural disasters. Earthquakes happen mainly near the edges of tectonic plates, but they may happen just about anywhere. Earthquakes cannot be predicted. Quick response after disasters, like earthquake, decreases loss of life and costs. Massive earthquakes often cause structures to collapse, trapping victims under dense rubble for long periods of time. After the earthquake and destroyed some areas, several teams are sent to find the location of the destroyed areas. The search and rescue phase usually is maintained for many days. Time reduction for surviving people is very important. A Geographical Information System (GIS) can be used for decreasing response time and management in critical situations. Position estimation in short period of time time is important. This paper proposes a GIS based system for post-earthquake disaster management solution. This system relies on several mobile positioning methods such as cell-ID and TA method, signal strength method, angel of arrival method, time of arrival method and time difference of arrival method. For quick positioning, the system can be helped by any person who has a mobile device. After positioning and specifying the critical points, the points are sent to a central site for managing the procedure of quick response for helping. This solution establishes a quick way to manage the post-earthquake crisis.
Low-pressure membrane integrity tests for drinking water treatment: A review.
Guo, H; Wyart, Y; Perot, J; Nauleau, F; Moulin, P
2010-01-01
Low-pressure membrane systems, including microfiltration (MF) and ultrafiltration (UF) membranes, are being increasingly used in drinking water treatments due to their high level of pathogen removal. However, the pathogen will pass through the membrane and contaminate the product if the membrane integrity is compromised. Therefore, an effective on-line integrity monitoring method for MF and UF membrane systems is essential to guarantee the regulatory requirements for pathogen removal. A lot of works on low-pressure membrane integrity tests have been conducted by many researchers. This paper provides a literature review about different low-pressure membrane integrity monitoring methods for the drinking water treatment, including direct methods (pressure-based tests, acoustic sensor test, liquid porosimetry, etc.) and indirect methods (particle counting, particle monitoring, turbidity monitoring, surrogate challenge tests). Additionally, some information about the operation of membrane integrity tests is presented here. It can be realized from this review that it remains urgent to develop an alternative on-line detection technique for a quick, accurate, simple, continuous and relatively inexpensive evaluation of low-pressure membrane integrity. To better satisfy regulatory requirements for drinking water treatments, the characteristic of this ideal membrane integrity test is proposed at the end of this paper.
Klopp, R N; Oconitrillo, M J; Sackett, A; Hill, T M; Schlotterbeck, R L; Lascano, G J
2018-07-01
A limited amount of research is available related to the rumen microbiota of calves, yet there has been a recent spike of interest in determining the diversity and development of calf rumen microbial populations. To study the microbial populations of a calf's rumen, a sample of the rumen fluid is needed. One way to take a rumen fluid sample from a calf is by fistulating the animal. This method requires surgery and can be very stressful on a young animal that is trying to adapt to a new environment and has a depressed immune system. Another method that can be used instead of fistulation surgery is a rumen pump. This method requires a tube to be inserted into the rumen through the calf's esophagus. Once inside the rumen, fluid can be pumped out and collected in a few minutes. This method is quick, inexpensive, and does not cause significant stress on the animal. This technical note presents the materials and methodology used to convert a drenching system into a rumen pump and its respective utilization in 2 experiments using dairy bull calves. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Douša, Michal; Pivoňková, Veronika; Sýkora, David
2016-08-01
A rapid procedure for the determination of memantine based on hydrophilic interaction chromatography with fluorescence detection was developed. Fluorescence detection after postcolumn derivatization with o-phtaldialdehyde/2-mercaptoethanol was performed at excitation and emission wavelengths of 345 and 450 nm, respectively. The postcolumn reaction conditions such as reaction temperature, derivatization reagent flow rate, and reagents concentration were studied due to steric hindrance of amino group of memantine. The derivatization reaction was applied for the hydrophilic interaction liquid chromatography method which was based on Cogent Silica-C stationary phase with a mobile phase consisting of a mixture of 10 mmol/L citric acid and 10 mmol/L o-phosphoric acid (pH 6.0) with acetonitrile using an isocratic composition of 2:8 v/v. The benefit of the reported approach consists in a simple sample pretreatment and a quick and sensitive hydrophilic interaction chromatography method. The developed method was validated in terms of linearity, accuracy, precision, and selectivity according to the International Conference on Harmonisation guidelines. The developed method was successfully applied for the analysis of commercial memantine tablets. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Rower, Joseph E.; Bushman, Lane R.; Hammond, Kyle P.; Kadam, Rajendra S.; Aquilante, Christina L.
2011-01-01
Gemfibrozil, a fibric acid hypolipidemic agent, is increasingly being used in clinical drug-drug interaction studies as an inhibitor of drug metabolizing enzymes and drug transporters. The validation of a fast, accurate, and precise LC/MS method is described for the quantitative determination of gemfibrozil in an EDTA-anticoagulated human plasma matrix. Briefly, gemfibrozil was extracted from human plasma by an acetonitrile protein precipitation method. The assay was reproducible with intra-assay precision between 1.6% and 10.7%, and inter-assay precision ranging from 4.4% to 7.8%. The assay also showed good accuracy, with intra-assay concentrations within 85.6% and 108.7% of the expected value, and inter-assay concentrations within 89.4 to 104.0% of the expected value. The linear concentration range was between 0.5 and 50 μg/mL with a lower limit of quantitation of 0.5 μg/mL when 125 μL of plasma were extracted. This LC/MS method yielded a quick, simple, and reliable protocol for determining gemfibrozil concentrations in plasma and is applicable to clinical pharmacokinetic studies. PMID:21077249
Rower, Joseph E; Bushman, Lane R; Hammond, Kyle P; Kadam, Rajendra S; Aquilante, Christina L
2010-12-01
Gemfibrozil, a fibric acid hypolipidemic agent, is increasingly being used in clinical drug-drug interaction studies as an inhibitor of drug metabolizing enzymes and drug transporters. The validation of a fast, accurate and precise LC/MS method is described for the quantitative determination of gemfibrozil in an EDTA-anticoagulated human plasma matrix. Briefly, gemfibrozil was extracted from human plasma by an acetonitrile protein precipitation method. The assay was reproducible with intra-assay precision between 1.6 and 10.7%, and inter-assay precision ranging from 4.4 to 7.8%. The assay also showed good accuracy, with intra-assay concentrations within 85.6-108.7% of the expected value, and inter-assay concentrations within 89.4-104.0% of the expected value. The linear concentration range was between 0.5 and 50 µg/mL with a lower limit of quantitation of 0.5 µg/mL when 125 µL of plasma were extracted. This LC/MS method yielded a quick, simple and reliable protocol for determining gemfibrozil concentrations in plasma and is applicable to clinical pharmacokinetic studies. Copyright © 2010 John Wiley & Sons, Ltd.
Linearized self-consistent quasiparticle GW method: Application to semiconductors and simple metals
NASA Astrophysics Data System (ADS)
Kutepov, A. L.; Oudovenko, V. S.; Kotliar, G.
2017-10-01
We present a code implementing the linearized quasiparticle self-consistent GW method (LQSGW) in the LAPW basis. Our approach is based on the linearization of the self-energy around zero frequency which differs it from the existing implementations of the QSGW method. The linearization allows us to use Matsubara frequencies instead of working on the real axis. This results in efficiency gains by switching to the imaginary time representation in the same way as in the space time method. The all electron LAPW basis set eliminates the need for pseudopotentials. We discuss the advantages of our approach, such as its N3 scaling with the system size N, as well as its shortcomings. We apply our approach to study the electronic properties of selected semiconductors, insulators, and simple metals and show that our code produces the results very close to the previously published QSGW data. Our implementation is a good platform for further many body diagrammatic resummations such as the vertex-corrected GW approach and the GW+DMFT method. Program Files doi:http://dx.doi.org/10.17632/cpchkfty4w.1 Licensing provisions: GNU General Public License Programming language: Fortran 90 External routines/libraries: BLAS, LAPACK, MPI (optional) Nature of problem: Direct implementation of the GW method scales as N4 with the system size, which quickly becomes prohibitively time consuming even in the modern computers. Solution method: We implemented the GW approach using a method that switches between real space and momentum space representations. Some operations are faster in real space, whereas others are more computationally efficient in the reciprocal space. This makes our approach scale as N3. Restrictions: The limiting factor is usually the memory available in a computer. Using 10 GB/core of memory allows us to study the systems up to 15 atoms per unit cell.
Hsieh, Han-Yun; Shyu, Ching-Lin; Liao, Chen-Wei; Lee, Ren-Jye; Lee, Maw-Rong; Vickroy, Thomas W; Chou, Chi-Chung
2012-04-01
Zeranol (Z) is a semi-synthetic mycotoxin that is used in some countries as a growth-promoting agent in livestock. In view of the known oestrogenic actions by Z and certain Z analogues, significant concerns exist with regard to the presence of Z residues in human foods and the potential for untoward effects, including carcinogenicity within the reproductive system. In order to confirm that foods are free from harmful Z residues, regulators need a quick and reliable analytical method that can be used for routine confirmation of Z-positive samples identified by enzyme-linked immunosorbent assay (ELISA) screening. In this study the authors have developed and validated a simple and rapid high-performance liquid chromatography method incorporating ultraviolet (UV) absorbance (wavelength 274 nm) and electrochemical (EC) dual-mode detection for simultaneous determination of Z-related mycotoxins produced from mouldy grain matrices, including rice, soybean and corn flakes. Recoveries for all analytes were around 80% and the limits of detection ranged from 10 to 25 ng mL(-1) for UV and from 50 to 90 ng mL(-1) for EC detection with good accuracy and reproducibility. Differential profiles and occurrence rates of Z, β-zearalenol, β-zearalanol and α-zearalenol in naturally moulded grain matrices were observed, indicating different metabolite patterns and possibly grain-specific effects of mycotoxin exposure for humans and animals. The strength of this dual detection method lies in its selectivity characterised by a carbon screen-printed electrode such that aflatoxin interference is precluded. The combined dual detection technique affords quick and reliable semi-confirmative and quantitative information on multiple types of Z analogues in mouldy grains without the necessity of using expensive mass spectrometry. The method is considered a superior supplement to ELISA, which only screens total Z immunoreactivity. Copyright © 2011 Society of Chemical Industry.
NASA Astrophysics Data System (ADS)
Mucciarelli, M.; Contri, P.; Monachesi, G.; Calvano, G.; Gallipoli, M.
- The seismic vulnerability of existing buildings is usually estimated according to procedures based on checklists of main structural features. The relationship with damage is then assessed using experience from past events. An approach used in seismology for the evaluation of site amplification, based on horizontal-to-vertical ratio of weak motion and microtremors, has been applied to the structural field. This methodology provides an alternative, promising tool towards a quick and reliable estimate of seismic vulnerability. The advantages are:• The measurements are quick, simple and stable. They are non-invasive and do not affect at all, even temporarily, the functions housed in the buildings studied.• The site effect and the soil structure interaction are explicitly accounted for in the vulnerability estimate, when they are excluded in the traditional approaches.• The relationship with damage is established using meaningful physical parameters related to the construction technology, instead of adimensional, normalised indexes. The procedure has been applied to several case histories of buildings damaged in the recent Umbria-Marche earthquake which occurred in Italy in 1997. The same model has been applied to different structures (brick/stone masonry and infilled r.c. frames), on different geological conditions and under very different seismic loads. Using this combined site/building approach, it was possible to explain very sharp variations in the damage pattern.
NASA Astrophysics Data System (ADS)
Droghei, Riccardo; Salusti, Ettore
2013-04-01
Control of drilling parameters, as fluid pressure, mud weight, salt concentration is essential to avoid instabilities when drilling through shale sections. To investigate shale deformation, fundamental for deep oil drilling and hydraulic fracturing for gas extraction ("fracking"), a non-linear model of mechanic and chemo-poroelastic interactions among fluid, solute and the solid matrix is here discussed. The two equations of this model describe the isothermal evolution of fluid pressure and solute density in a fluid saturated porous rock. Their solutions are quick non-linear Burger's solitary waves, potentially destructive for deep operations. In such analysis the effect of diffusion, that can play a particular role in fracking, is investigated. Then, following Civan (1998), both diffusive and shock waves are applied to fine particles filtration due to such quick transients , their effect on the adjacent rocks and the resulting time-delayed evolution. Notice how time delays in simple porous media dynamics have recently been analyzed using a fractional derivative approach. To make a tentative comparison of these two deeply different methods,in our model we insert fractional time derivatives, i.e. a kind of time-average of the fluid-rocks interactions. Then the delaying effects of fine particles filtration is compared with fractional model time delays. All this can be seen as an empirical check of these fractional models.
Delora, Adam; Gonzales, Aaron; Medina, Christopher S; Mitchell, Adam; Mohed, Abdul Faheem; Jacobs, Russell E; Bearer, Elaine L
2016-01-15
Magnetic resonance imaging (MRI) is a well-developed technique in neuroscience. Limitations in applying MRI to rodent models of neuropsychiatric disorders include the large number of animals required to achieve statistical significance, and the paucity of automation tools for the critical early step in processing, brain extraction, which prepares brain images for alignment and voxel-wise statistics. This novel timesaving automation of template-based brain extraction ("skull-stripping") is capable of quickly and reliably extracting the brain from large numbers of whole head images in a single step. The method is simple to install and requires minimal user interaction. This method is equally applicable to different types of MR images. Results were evaluated with Dice and Jacquard similarity indices and compared in 3D surface projections with other stripping approaches. Statistical comparisons demonstrate that individual variation of brain volumes are preserved. A downloadable software package not otherwise available for extraction of brains from whole head images is included here. This software tool increases speed, can be used with an atlas or a template from within the dataset, and produces masks that need little further refinement. Our new automation can be applied to any MR dataset, since the starting point is a template mask generated specifically for that dataset. The method reliably and rapidly extracts brain images from whole head images, rendering them useable for subsequent analytical processing. This software tool will accelerate the exploitation of mouse models for the investigation of human brain disorders by MRI. Copyright © 2015 Elsevier B.V. All rights reserved.
Qu, Lei; Chen, Jian-Bo; Zhang, Gui-Jun; Sun, Su-Qin; Zheng, Jing
2017-03-05
As a kind of expensive perfume and valuable herb, Aquilariae Lignum Resinatum (ALR) is often adulterated for economic motivations. In this research, Fourier transform infrared (FT-IR) spectroscopy is employed to establish a simple and quick method for the adulteration screening of ALR. First, the principal chemical constituents of ALR are characterized by FT-IR spectroscopy at room temperature and two-dimensional correlation infrared (2D-IR) spectroscopy with thermal perturbation. Besides the common cellulose and lignin compounds, a certain amount of resin is the characteristic constituent of ALR. Synchronous and asynchronous 2D-IR spectra indicate that the resin (an unstable secondary metabolite) is more sensitive than cellulose and lignin (stable structural constituents) to the thermal perturbation. Using a certified ALR sample as the reference, the infrared spectral correlation threshold is determined by 30 authentic samples and 6 adulterated samples. The spectral correlation coefficient of an authentic ALR sample to the standard reference should be not less than 0.9886 (p=0.01). Three commercial adulterated ALR samples are identified by the correlation threshold. Further interpretation of the infrared spectra of the adulterated samples indicates the common adulterating methods - counterfeiting with other kind of wood, adding ingredient such as sand to increase the weight, and adding the cheap resin such as rosin to increase the content of resin compounds. Results of this research prove that FT-IR spectroscopy can be used as a simple and accurate quality control method of ALR. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Qu, Lei; Chen, Jian-bo; Zhang, Gui-Jun; Sun, Su-qin; Zheng, Jing
2017-03-01
As a kind of expensive perfume and valuable herb, Aquilariae Lignum Resinatum (ALR) is often adulterated for economic motivations. In this research, Fourier transform infrared (FT-IR) spectroscopy is employed to establish a simple and quick method for the adulteration screening of ALR. First, the principal chemical constituents of ALR are characterized by FT-IR spectroscopy at room temperature and two-dimensional correlation infrared (2D-IR) spectroscopy with thermal perturbation. Besides the common cellulose and lignin compounds, a certain amount of resin is the characteristic constituent of ALR. Synchronous and asynchronous 2D-IR spectra indicate that the resin (an unstable secondary metabolite) is more sensitive than cellulose and lignin (stable structural constituents) to the thermal perturbation. Using a certified ALR sample as the reference, the infrared spectral correlation threshold is determined by 30 authentic samples and 6 adulterated samples. The spectral correlation coefficient of an authentic ALR sample to the standard reference should be not less than 0.9886 (p = 0.01). Three commercial adulterated ALR samples are identified by the correlation threshold. Further interpretation of the infrared spectra of the adulterated samples indicates the common adulterating methods - counterfeiting with other kind of wood, adding ingredient such as sand to increase the weight, and adding the cheap resin such as rosin to increase the content of resin compounds. Results of this research prove that FT-IR spectroscopy can be used as a simple and accurate quality control method of ALR.
Novel approach to automatically classify rat social behavior using a video tracking system.
Peters, Suzanne M; Pinter, Ilona J; Pothuizen, Helen H J; de Heer, Raymond C; van der Harst, Johanneke E; Spruijt, Berry M
2016-08-01
In the past, studies in behavioral neuroscience and drug development have relied on simple and quick readout parameters of animal behavior to assess treatment efficacy or to understand underlying brain mechanisms. The predominant use of classical behavioral tests has been repeatedly criticized during the last decades because of their poor reproducibility, poor translational value and the limited explanatory power in functional terms. We present a new method to monitor social behavior of rats using automated video tracking. The velocity of moving and the distance between two rats were plotted in frequency distributions. In addition, behavior was manually annotated and related to the automatically obtained parameters for a validated interpretation. Inter-individual distance in combination with velocity of movement provided specific behavioral classes, such as moving with high velocity when "in contact" or "in proximity". Human observations showed that these classes coincide with following (chasing) behavior. In addition, when animals are "in contact", but at low velocity, behaviors such as allogrooming and social investigation were observed. Also, low dose treatment with morphine and short isolation increased the time animals spent in contact or in proximity at high velocity. Current methods that involve the investigation of social rat behavior are mostly limited to short and relatively simple manual observations. A new and automated method for analyzing social behavior in a social interaction test is presented here and shows to be sensitive to drug treatment and housing conditions known to influence social behavior in rats. Copyright © 2016 Elsevier B.V. All rights reserved.
Epping, Ruben; Panne, Ulrich; Falkenhagen, Jana
2018-03-06
From simple homopolymers to functionalized, 3-dimensional structured copolymers, the complexity of polymeric materials has become more and more sophisticated. With new applications, for instance, in the semiconductor or pharmaceutical industry, the requirements for the characterization have risen with the complexity of the used polymers. For each additional distribution, an additional dimension in analysis is needed. Small, often isomeric heterogeneities in topology or microstructure can usually not be simply separated chromatographically or distinguished by any common detector but affect the properties of materials significantly. For a drug delivery system, for example, the degree of branching and branching distribution is crucial for the formation of micelles. Instead of a complicated, time-consuming, and/or expensive 2D-chromatography or ion mobility spectrometry (IMS) method, that also has its limitations, in this work, a simple approach using size exclusion chromatography (SEC) coupled with electrospray ionization (ESI) mass spectrometry is proposed. The online coupling allows the analysis of reconstructed ion chromatograms (RICs) of each degree of polymerization. While a complete separation often cannot be achieved, the derived retention times and peak widths lead to information on the existence and dispersity of heterogeneities. Although some microstructural heterogeneities like short chain branching can for large polymers be characterized with methods such as light scattering, for oligomers where the heterogeneities just start to form and their influence is at the maximum, they are inaccessible with these methods. It is also shown that with a proper calibration even quantitative information can be obtained. This method is suitable to detect small differences in, e.g., branching, 3D-structure, monomer sequence, or tacticity and could potentially be used in routine analysis to quickly determine deviations.
Hou, Fang; Lesmes, Luis Andres; Kim, Woojae; Gu, Hairong; Pitt, Mark A.; Myung, Jay I.; Lu, Zhong-Lin
2016-01-01
The contrast sensitivity function (CSF) has shown promise as a functional vision endpoint for monitoring the changes in functional vision that accompany eye disease or its treatment. However, detecting CSF changes with precision and efficiency at both the individual and group levels is very challenging. By exploiting the Bayesian foundation of the quick CSF method (Lesmes, Lu, Baek, & Albright, 2010), we developed and evaluated metrics for detecting CSF changes at both the individual and group levels. A 10-letter identification task was used to assess the systematic changes in the CSF measured in three luminance conditions in 112 naïve normal observers. The data from the large sample allowed us to estimate the test–retest reliability of the quick CSF procedure and evaluate its performance in detecting CSF changes at both the individual and group levels. The test–retest reliability reached 0.974 with 50 trials. In 50 trials, the quick CSF method can detect a medium 0.30 log unit area under log CSF change with 94.0% accuracy at the individual observer level. At the group level, a power analysis based on the empirical distribution of CSF changes from the large sample showed that a very small area under log CSF change (0.025 log unit) could be detected by the quick CSF method with 112 observers and 50 trials. These results make it plausible to apply the method to monitor the progression of visual diseases or treatment effects on individual patients and greatly reduce the time, sample size, and costs in clinical trials at the group level. PMID:27120074
In situ two-dimensional imaging quick-scanning XAFS with pixel array detector.
Tanida, Hajime; Yamashige, Hisao; Orikasa, Yuki; Oishi, Masatsugu; Takanashi, Yu; Fujimoto, Takahiro; Sato, Kenji; Takamatsu, Daiko; Murayama, Haruno; Arai, Hajime; Matsubara, Eiichiro; Uchimoto, Yoshiharu; Ogumi, Zempachi
2011-11-01
Quick-scanning X-ray absorption fine structure (XAFS) measurements were performed in transmission mode using a PILATUS 100K pixel array detector (PAD). The method can display a two-dimensional image for a large area of the order of a centimetre with a spatial resolution of 0.2 mm at each energy point in the XAFS spectrum. The time resolution of the quick-scanning method ranged from 10 s to 1 min per spectrum depending on the energy range. The PAD has a wide dynamic range and low noise, so the obtained spectra have a good signal-to-noise ratio.
RECOVERY OF VALUABLE MATERIAL FROM GRAPHITE BODIES
Fromm, L.W. Jr.
1959-09-01
An electrolytic process for recovering uranium from a graphite fuel element is described. The uraniumcontaining graphite body is disposed as the anode of a cell containing a nitric acid electrolyte and a 5 amp/cm/sup 2/ current passed to induce a progressive disintegration of the graphite body. The dissolved uranium is quickly and easily separated from the resulting graphite particles by simple mechanical means, such as centrifugation, filtration, and decontamination.
Designing and Implementing a Clinician Workstation
Tape, Thomas G.; Campbell, James R.
1993-01-01
We describe a simple approach to designing and quickly implementing a clinician workstation that helps practitioners access a variety of information resources. Using easy-to-use graphical tools, we installed a pilot workstation in our clinics. We were able to accommodate most of our users' needs and have a functional workstation installed in two months. This is the first step of an evolutionary process moving from separate tasks to full application integration.
Anomaly detection for analysis of annual inventory data: a quality control approach
Francis A. Roesch; Paul C. Van Deusen
2010-01-01
Annual forest inventories present special challenges and opportunities for those analyzing the data arising from them. Here, we address one question currently being asked by analysts of the US Forest Serviceâs Forest Inventory and Analysis Programâs quickly accumulating annual inventory data. The question is simple but profound: When combining the next yearâs data for...
Liu, Zhong; Sheng, Ping; Yang, Yan-Ping; Li, Wen; Huang, Wen-Ming; Wang, Jie-Di; Fan, Yi-Ming
2015-05-01
The diagnostic value of modified Chicago sky blue (CSB) stain and potassium hydroxide (KOH) mount for superficial mycoses was compared using fungal culture as gold standard. The sensitivity and screening time of the CSB stain were superior to the KOH mount. The CBS stain is simple, quick and reliable for diagnosing superficial mycoses. Copyright © 2015. Published by Elsevier B.V.
The Class of 2010: Economic Prospects for Young Adults in the Recession. EPI Briefing Paper #265
ERIC Educational Resources Information Center
Bivens, Josh; Edwards, Kathryn Anne; Hertel-Fernandez, Alexander; Turner, Anna
2010-01-01
It will take years for the labor market to recover from the damage induced by the recent recession. While monthly job losses almost surely peaked in 2009, the unemployment rate will likely peak in 2010 (CBO 2010a). In April, the unemployment rate reached 9.9% and the overall economic cause is simple: firms are not hiring quickly enough, as…
Simple motor tasks independently predict extubation failure in critically ill neurological patients
Kutchak, Fernanda Machado; Rieder, Marcelo de Mello; Victorino, Josué Almeida; Meneguzzi, Carla; Poersch, Karla; Forgiarini, Luiz Alberto; Bianchin, Marino Muxfeldt
2017-01-01
ABSTRACT Objective: To evaluate the usefulness of simple motor tasks such as hand grasping and tongue protrusion as predictors of extubation failure in critically ill neurological patients. Methods: This was a prospective cohort study conducted in the neurological ICU of a tertiary care hospital in the city of Porto Alegre, Brazil. Adult patients who had been intubated for neurological reasons and were eligible for weaning were included in the study. The ability of patients to perform simple motor tasks such as hand grasping and tongue protrusion was evaluated as a predictor of extubation failure. Data regarding duration of mechanical ventilation, length of ICU stay, length of hospital stay, mortality, and incidence of ventilator-associated pneumonia were collected. Results: A total of 132 intubated patients who had been receiving mechanical ventilation for at least 24 h and who passed a spontaneous breathing trial were included in the analysis. Logistic regression showed that patient inability to grasp the hand of the examiner (relative risk = 1.57; 95% CI: 1.01-2.44; p < 0.045) and protrude the tongue (relative risk = 6.84; 95% CI: 2.49-18.8; p < 0.001) were independent risk factors for extubation failure. Acute Physiology and Chronic Health Evaluation II scores (p = 0.02), Glasgow Coma Scale scores at extubation (p < 0.001), eye opening response (p = 0.001), MIP (p < 0.001), MEP (p = 0.006), and the rapid shallow breathing index (p = 0.03) were significantly different between the failed extubation and successful extubation groups. Conclusions: The inability to follow simple motor commands is predictive of extubation failure in critically ill neurological patients. Hand grasping and tongue protrusion on command might be quick and easy bedside tests to identify neurocritical care patients who are candidates for extubation. PMID:28746528
NASA Technical Reports Server (NTRS)
Weddendorf, Bruce (Inventor)
1994-01-01
A quick connect fastener and method of use is presented wherein the quick connect fastener is suitable for replacing available bolts and screws, the quick connect fastener being capable of installation by simply pushing a threaded portion of the connector into a member receptacle hole, the inventive apparatus being comprised of an externally threaded fastener having a threaded portion slidably mounted upon a stud or bolt shaft, wherein the externally threaded fastener portion is expandable by a preloaded spring member. The fastener, upon contact with the member receptacle hole, has the capacity of presenting cylindrical threads of a reduced diameter for insertion purposes and once inserted into the receiving threads of the receptacle member hole, are expandable for engagement of the receptacle hole threads forming a quick connect of the fastener and the member to be fastened, the quick connect fastener can be further secured by rotation after insertion, even to the point of locking engagement, the quick connect fastener being disengagable only by reverse rotation of the mated thread engagement.
NASA Astrophysics Data System (ADS)
Kuki, Ákos; Czifrák, Katalin; Karger-Kocsis, József; Zsuga, Miklós; Kéki, Sándor
2015-02-01
The prediction of shape-memory behavior is essential regarding the design of a smart material for different applications. This paper proposes a simple and quick method for the prediction of shape-memory behavior of amorphous shape memory polymers (SMPs) on the basis of a single dynamic mechanical analysis (DMA) temperature sweep at constant frequency. All the parameters of the constitutive equations for linear viscoelasticity are obtained by fitting the DMA curves. The change with the temperature of the time-temperature superposition shift factor ( a T ) is expressed by the Williams-Landel-Ferry (WLF) model near and above the glass transition temperature ( T g ), and by the Arrhenius law below T g . The constants of the WLF and Arrhenius equations can also be determined. The results of our calculations agree satisfactorily with the experimental free recovery curves from shape-memory tests.
Algorithm of first-aid management of dental trauma for medics and corpsmen.
Zadik, Yehuda
2008-12-01
In order to fill the discrepancy between the necessity of providing prompt and proper treatment to dental trauma patients, and the inadequate knowledge among medics and corpsmen, as well as the lack of instructions in first-aid textbook and manuals, and after reviewing the dental literature, a simple algorithm for non-professional first-aid management for various injuries to hard (teeth) and soft oral tissues, is presented. The recommended management of tooth avulsion, subluxation and luxation, crown fracture and lip, tongue or gingival laceration included in the algorithm. Along with a list of after-hour dental clinics, this symptoms- and clinical-appearance-based algorithm is suited to tuck easily into a pocket for quick utilization by medics/corpsmen in an emergency situation. Although the algorithm was developed for the usage of military non-dental health-care providers, this method could be adjusted and employed in the civilian environment as well.
Stewart, Eugene L; Brown, Peter J; Bentley, James A; Willson, Timothy M
2004-08-01
A methodology for the selection and validation of nuclear receptor ligand chemical descriptors is described. After descriptors for a targeted chemical space were selected, a virtual screening methodology utilizing this space was formulated for the identification of potential NR ligands from our corporate collection. Using simple descriptors and our virtual screening method, we are able to quickly identify potential NR ligands from a large collection of compounds. As validation of the virtual screening procedure, an 8, 000-membered NR targeted set and a 24, 000-membered diverse control set of compounds were selected from our in-house general screening collection and screened in parallel across a number of orphan NR FRET assays. For the two assays that provided at least one hit per set by the established minimum pEC(50) for activity, the results showed a 2-fold increase in the hit-rate of the targeted compound set over the diverse set.
A practical method of estimating stature of bedridden female nursing home patients.
Muncie, H L; Sobal, J; Hoopes, J M; Tenney, J H; Warren, J W
1987-04-01
Accurate measurement of stature is important for the determination of several nutritional indices as well as body surface area (BSA) for the normalization of creatinine clearances. Direct standing measurement of stature of bedridden elderly nursing home patients is impossible, and stature as recorded in the chart may not be valid. An accurate stature obtained by summing five segmental measurements was compared to the stature recorded in the patient's chart and calculated estimates of stature from measurement of a long bone (humerus, tibia, knee height). Estimation of stature from measurement of knee height was highly correlated (r = 0.93) to the segmental measurement of stature while estimates from other long-bone measurements were less highly correlated (r = 0.71 to 0.81). Recorded chart stature was poorly correlated (r = 0.37). Measurement of knee height provides a simple, quick, and accurate means of estimating stature for bedridden females in nursing homes.
Tomassetti, Mauro; Merola, Giovanni; Martini, Elisabetta; Campanella, Luigi; Sanzò, Gabriella; Favero, Gabriele; Mazzei, Franco
2017-01-01
In this research, we developed a direct-flow surface plasmon resonance (SPR) immunosensor for ampicillin to perform direct, simple, and fast measurements of this important antibiotic. In order to better evaluate the performance, it was compared with a conventional amperometric immunosensor, working with a competitive format with the aim of finding out experimental real advantages and disadvantages of two respective methods. Results showed that certain analytical features of the new SPR immunodevice, such as the lower limit of detection (LOD) value and the width of the linear range, are poorer than those of a conventional amperometric immunosensor, which adversely affects the application to samples such as natural waters. On the other hand, the SPR immunosensor was more selective to ampicillin, and measurements were more easily and quickly attained compared to those performed with the conventional competitive immunosensor. PMID:28394296
Targeted post-mortem computed tomography cardiac angiography: proof of concept.
Saunders, Sarah L; Morgan, Bruno; Raj, Vimal; Robinson, Claire E; Rutty, Guy N
2011-07-01
With the increasing use and availability of multi-detector computed tomography and magnetic resonance imaging in autopsy practice, there has been an international push towards the development of the so-called near virtual autopsy. However, currently, a significant obstacle to the consideration as to whether or not near virtual autopsies could one day replace the conventional invasive autopsy is the failure of post-mortem imaging to yield detailed information concerning the coronary arteries. To date, a cost-effective, practical solution to allow high throughput imaging has not been presented within the forensic literature. We present a proof of concept paper describing a simple, quick, cost-effective, manual, targeted in situ post-mortem cardiac angiography method using a minimally invasive approach, to be used with multi-detector computed tomography for high throughput cadaveric imaging which can be used in permanent or temporary mortuaries.
Rosas-Cholula, Gerardo; Ramirez-Cortes, Juan Manuel; Alarcon-Aquino, Vicente; Gomez-Gil, Pilar; Rangel-Magdaleno, Jose de Jesus; Reyes-Garcia, Carlos
2013-08-14
This paper presents a project on the development of a cursor control emulating the typical operations of a computer-mouse, using gyroscope and eye-blinking electromyographic signals which are obtained through a commercial 16-electrode wireless headset, recently released by Emotiv. The cursor position is controlled using information from a gyroscope included in the headset. The clicks are generated through the user's blinking with an adequate detection procedure based on the spectral-like technique called Empirical Mode Decomposition (EMD). EMD is proposed as a simple and quick computational tool, yet effective, aimed to artifact reduction from head movements as well as a method to detect blinking signals for mouse control. Kalman filter is used as state estimator for mouse position control and jitter removal. The detection rate obtained in average was 94.9%. Experimental setup and some obtained results are presented.
Rosas-Cholula, Gerardo; Ramirez-Cortes, Juan Manuel; Alarcon-Aquino, Vicente; Gomez-Gil, Pilar; Rangel-Magdaleno, Jose de Jesus; Reyes-Garcia, Carlos
2013-01-01
This paper presents a project on the development of a cursor control emulating the typical operations of a computer-mouse, using gyroscope and eye-blinking electromyographic signals which are obtained through a commercial 16-electrode wireless headset, recently released by Emotiv. The cursor position is controlled using information from a gyroscope included in the headset. The clicks are generated through the user's blinking with an adequate detection procedure based on the spectral-like technique called Empirical Mode Decomposition (EMD). EMD is proposed as a simple and quick computational tool, yet effective, aimed to artifact reduction from head movements as well as a method to detect blinking signals for mouse control. Kalman filter is used as state estimator for mouse position control and jitter removal. The detection rate obtained in average was 94.9%. Experimental setup and some obtained results are presented. PMID:23948873
A study of Radar Cross Section (RCS) characteristics and their application in future weapon systems
NASA Astrophysics Data System (ADS)
McCluggage, W. A.
The sum of components technique was used to calculate the radar cross section (RCS) of a Canberra B2 aircraft. The theoretical result obtained by using simple shapes to model the aircraft were compared with practical results. It is found that this technique can be used to give a quick order of magnitude estimation of a target's RCS. However, the major drawback of this technique is that it cannot predict the rapid changes in RCS which result from a small change in aspect angle. Trends in radar guided weapons, the effects of aircraft shape on the overall RCS of a weapons platform, and reduction of aircraft RCS by appropriate shaping are discussed. Methods, including radar absorption, radar absorbing materials, impedance loading, and active cancellation, which can be used to reduce an aircraft's radar signature and the associated penalties are reviewed.
Do Athletes Excel at Everyday Tasks?
CHADDOCK, LAURA; NEIDER, MARK B.; VOSS, MICHELLE W.; GASPAR, JOHN G.; KRAMER, ARTHUR F.
2014-01-01
Purpose Cognitive enhancements are associated with sport training. We extended the sport-cognition literature by using a realistic street crossing task to examine the multitasking and processing speed abilities of collegiate athletes and nonathletes. Methods Pedestrians navigated trafficked roads by walking on a treadmill in a virtual world, a challenge that requires the quick and simultaneous processing of multiple streams of information. Results Athletes had higher street crossing success rates than nonathletes, as reflected by fewer collisions with moving vehicles. Athletes also showed faster processing speed on a computer-based test of simple reaction time, and shorter reaction times were associated with higher street crossing success rates. Conclusions The results suggest that participation in athletics relates to superior street crossing multitasking abilities and that athlete and nonathlete differences in processing speed may underlie this difference. We suggest that cognitive skills trained in sport may transfer to performance on everyday fast-paced multitasking abilities. PMID:21407125
Dual-Mechanism and Multimotion Soft Actuators Based on Commercial Plastic Film.
Li, Linpeng; Meng, Junxing; Hou, Chengyi; Zhang, Qinghong; Li, Yaogang; Yu, Hao; Wang, Hongzhi
2018-05-02
Soft actuators have attracted a lot of attention owing to their biomimetic performance. However, the development of soft actuators that are easily prepared from readily available raw materials, conveniently utilized, and cost-efficient is still a challenge. Here, we present a simple method to fabricate a polyethylene-based soft actuator. It has controllable anisotropic structure and can realize multiple motions, including bidirectional bending and twisting based on dual mechanisms, which is a rare phenomenon. Especially, the soft actuators can response at a very small temperature difference (Δ T ≥ 2.3 °C); therefore, even skin touch can quickly drive the actuator, which greatly broadens its applications in daily life. The soft actuator could demonstrate a curvature up to 7.8 cm -1 accompanied by powerful actuation. We have shown that it can lift an object 27 times its own weight. We also demonstrate the application of this actuator as intelligent mechanical devices.
Motor imagery: lessons learned in movement science might be applicable for spaceflight
Bock, Otmar; Schott, Nadja; Papaxanthis, Charalambos
2015-01-01
Before participating in a space mission, astronauts undergo parabolic-flight and underwater training to facilitate their subsequent adaptation to weightlessness. Unfortunately, similar training methods can’t be used to prepare re-adaptation to planetary gravity. Here, we propose a quick, simple and inexpensive approach that could be used to prepare astronauts both for the absence and for the renewed presence of gravity. This approach is based on motor imagery (MI), a process in which actions are produced in working memory without any overt output. Training protocols based on MI have repeatedly been shown to modify brain circuitry and to improve motor performance in healthy young adults, healthy seniors and stroke victims, and are routinely used to optimize performance of elite athletes. We propose to use similar protocols preflight, to prepare for weightlessness, and late inflight, to prepare for landing. PMID:26042004
Mirador: A Simple, Fast Search Interface for Remote Sensing Data
NASA Technical Reports Server (NTRS)
Lynnes, Christopher; Strub, Richard; Seiler, Edward; Joshi, Talak; MacHarrie, Peter
2008-01-01
A major challenge for remote sensing science researchers is searching and acquiring relevant data files for their research projects based on content, space and time constraints. Several structured query (SQ) and hierarchical navigation (HN) search interfaces have been develop ed to satisfy this requirement, yet the dominant search engines in th e general domain are based on free-text search. The Goddard Earth Sci ences Data and Information Services Center has developed a free-text search interface named Mirador that supports space-time queries, inc luding a gazetteer and geophysical event gazetteer. In order to compe nsate for a slightly reduced search precision relative to SQ and HN t echniques, Mirador uses several search optimizations to return result s quickly. The quick response enables a more iterative search strateg y than is available with many SQ and HN techniques.
Li, Xiaofang; Deng, Linhong; Lu, Hu; He, Bin
2014-08-01
A measurement system based on the image processing technology and developed by LabVIEW was designed to quickly obtain the range of motion (ROM) of spine. NI-Vision module was used to pre-process the original images and calculate the angles of marked needles in order to get ROM data. Six human cadaveric thoracic spine segments T7-T10 were selected to carry out 6 kinds of loads, including left/right lateral bending, flexion, extension, cis/counterclockwise torsion. The system was used to measure the ROM of segment T8-T9 under the loads from 1 Nm to 5 Nm. The experimental results showed that the system is able to measure the ROM of the spine accurately and quickly, which provides a simple and reliable tool for spine biomechanics investigators.
Implicit Self-Importance in an Interpersonal Pronoun Categorization Task.
Fetterman, Adam K; Robinson, Michael D; Gilbertson, Elizabeth P
2014-06-01
Object relations theories emphasize the manner in which the salience/importance of implicit representations of self and other guide interpersonal functioning. Two studies and a pilot test (total N = 304) sought to model such representations. In dyadic contexts, the self is a "you" and the other is a "me", as verified in a pilot test. Study 1 then used a simple categorization task and found evidence for implicit self-importance: The pronoun "you" was categorized more quickly and accurately when presented in a larger font size, whereas the pronoun "me" was categorized more quickly and accurately when presented in a smaller font size. Study 2 showed that this pattern possesses value in understanding individual differences in interpersonal functioning. As predicted, arrogant people scored higher in implicit self-importance in the paradigm. Findings are discussed from the perspective of dyadic interpersonal dynamics.
Fontana, Ariel R; Bottini, Rubén
2014-05-16
In this work, a reliable, simple, fast, inexpensive and robust sample preparation approach for the determination of multiclass polyphenols in wine samples is proposed. The polyphenols selected for this work were gallic acid, (+)-catechin, (-)-epicatechin, caffeic acid, syringic acid, coumaric acid, ferulic acid, trans-resveratrol, quercetin and cinnamic acid. The method is based on QuEChERS (quick, easy, cheap, effective, rugged and safe) extraction technique coupled with dispersive solid-phase extraction (d-SPE) clean-up. Under optimized conditions, the analytes were extracted from 5mL wine samples (previously acidified with 1% formic acid) using 2.5mL acetonitrile. For phase separation, 1.5g NaCl and 4g anhydrous MgSO4 were added. Then, a 1mL aliquot of the partitioned supernatant was cleaned-up using d-SPE with a combination of 150mg CaCl2, 50mg primary-secondary amine (PSA) and 50mgC18 as sorbents. A 250μL aliquot of the obtained cleaned extract was concentrated to dryness and taken up with the initial mobile phase previous to liquid chromatography-multi-wavelength detection (LC-MWD). The proposed method provided limits of detection (LODs) ranging from 0.004 to 0.079μgmL(-1) and an inter-day variability below 12% RSD for all analytes in red and white wine samples. Considering external calibration (red wines) and matrix-matched calibration (white wines) as quantification techniques, the overall recoveries (accuracy) of the method ranged between 75.0% and 119.6% for red and white wine samples, respectively. The developed method was applied for the determination of polyphenols in 10 wines produced in Argentina. Nine phenolic compounds were determined, at concentrations above detectable levels in the method. The maximum concentrations corresponded to (-)-epicatechin in white wines, while gallic acid and (+)-catechin were the most abundant in red wines. Copyright © 2014 Elsevier B.V. All rights reserved.
Medeiros, Roberta Antigo; Lourenção, Bruna Cláudia; Rocha-Filho, Romeu Cardozo; Fatibello-Filho, Orlando
2010-10-15
A method for simultaneous determination of butylated hydroxyanisole (BHA) and butylated hydroxytoluene (BHT) in food was developed that uses multiple pulse amperometry (MPA) with flow injection analysis (FIA). Determination of these phenolic antioxidants was carried out with a cathodically pretreated boron-doped diamond electrode and an aqueous ethanolic (30% ethanol, v/v) 10 mmol L⁻¹ KNO₃ solution (pH(cond) = 1.5) as supporting electrolyte. A dual-potential waveform, at E(det1) = 850 mV/200 ms and E(det2) = 1150 mV/200 ms versus Ag/AgCl (3.0 mol L⁻¹ KCl), was employed. The use of E(det1) or E(det2) caused the oxidation of BHA or of BHA and BHT, respectively; hence, concentration subtraction could be used to determine both species. The respective analytical curves presented good linearity in the investigated concentration range (0.050-3.0 μmol L⁻¹ for BHA and 0.70-70 μmol L⁻¹ for BHT), and the detection limits were 0.030 μmol L⁻¹ for BHA and 0.40 μmol L⁻¹ for BHT. The proposed method, which is simple, quick, and presents good precision and accuracy, was successfully applied in the simultaneous determination of BHA and BHT in commercial mayonnaise samples, with results similar to those obtained by HPLC, at a 95% confidence level.
Yu, Kun-Zi; Yan, Hua; Tai, Hai-Chuan; Zhang, Nan-Ping; Cheng, Xian-Long; Guo, Zeng-Xi; Ma, Shuang-Cheng; Wei, Feng
2017-07-01
The Chinese Materia Medica, Tiepishihu, used as a tonic for over one thousand years, is a well-known precious medicine in China. According to the Chinese Pharmacopoeia, its source is the species Dendrobium officinale Kimura et Migo, which is distinguished from other species in Dendrobium genus. However, these species from the same genus are similar with Tiepishihu and caused confusion in the market. To find a quick and simple method to distinguish Tiepishihu from other similar species, histologic and microscopic methods were combined together to investigate the transverse section of stem of Tiepishihu and other similar species. Phloroglucinol test solution with hydrochloric acid was used to reveal the lignified tissue by staining the transverse section of Tiepishihu and similar species. Results revealed the unique identification characteristics to distinguish Tiepishihu from similar species, which were difficult to distinguish by other methods. The identification characteristics of Tiepishihu include the cells of vascular bundle sheath were stained red, parenchyma cells were not stained red. What's more, other species can be distinguished from each other with microscopic and histological characteristics. These characteristics proved stable and can be easily observed by normal light microscopic examination. This method is rapid, accurate, stable, and inexpensive. © 2017 Wiley Periodicals, Inc.
Sung, Jun Hyun; Lee, Young Ja; Park, Hyun Jin
2008-08-01
A new method was developed for the determination of epichlorohydrin (ECH) in food contact surface of epoxy-coated cans. The oxolane derivative, which produced by reaction of epoxy moiety in ECH with cyclopentanone in the presence of borontrifluoride-diethyletherate, was analyzed by gas chromatography (GC)/mass spectrometry (MS). 1,2-Epoxyhexane was used as internal standard (IS), which produced an oxolane derivative under the same reaction mechanism as ECH. The developed method was validated with 1 ng ml(-1) of limit of detection (LOD, surface area related 20 ng dm(-2)), >0.999 of linearity. Good precision, which was tested both in terms of intra-day repeatability and inter-day reproducibility, and 97.3-102.7% of good recoveries were obtained on three spiked levels of 5.2, 40.3 and 149.1 ng ml(-1). The excellent validation data suggests that this method is more simple, quick and effective than the official method in European Committee for Standardization (CEN) to determine the residual amount of ECH in food contact materials for food law compliance test. The residual amount of ECH for 13 epoxy-coated can samples was analyzed, and none of the samples was found to be detectable levels of ECH in epoxy-coated cans.
Identification of spider-mite species and their endosymbionts using multiplex PCR.
Zélé, Flore; Weill, Mylène; Magalhães, Sara
2018-02-01
Spider mites of the genus Tetranychidae are severe crop pests. In the Mediterranean a few species coexist, but they are difficult to identify based on morphological characters. Additionally, spider mites often harbour several species of endosymbiotic bacteria, which may affect the biology of their hosts. Here, we propose novel, cost-effective, multiplex diagnostic methods allowing a quick identification of spider-mite species as well as of the endosymbionts they carry. First, we developed, and successfully multiplexed in a single PCR, primers to identify Tetranychus urticae, T. evansi and T. ludeni, some of the most common tetranychids found in southwest Europe. Moreover, we demonstrated that this method allows detecting multiple species in a single pool, even at low frequencies (up to 1/100), and can be used on entire mites without DNA extraction. Second, we developed another set of primers to detect spider-mite endosymbionts, namely Wolbachia, Cardinium and Rickettsia in a multiplex PCR, along with a generalist spider-mite primer to control for potential failure of DNA amplification in each PCR. Overall, our method represents a simple, cost-effective and reliable method to identify spider-mite species and their symbionts in natural field populations, as well as to detect contaminations in laboratory rearings. This method may easily be extended to other species.
Impacts of snow cover fraction data assimilation on modeled energy and moisture budgets
NASA Astrophysics Data System (ADS)
Arsenault, Kristi R.; Houser, Paul R.; De Lannoy, Gabriëlle J. M.; Dirmeyer, Paul A.
2013-07-01
Two data assimilation (DA) methods, a simple rule-based direct insertion (DI) approach and a one-dimensional ensemble Kalman filter (EnKF) method, are evaluated by assimilating snow cover fraction observations into the Community Land surface Model. The ensemble perturbation needed for the EnKF resulted in negative snowpack biases. Therefore, a correction is made to the ensemble bias using an approach that constrains the ensemble forecasts with a single unperturbed deterministic LSM run. This is shown to improve the final snow state analyses. The EnKF method produces slightly better results in higher elevation locations, whereas results indicate that the DI method has a performance advantage in lower elevation regions. In addition, the two DA methods are evaluated in terms of their overall impacts on the other land surface state variables (e.g., soil moisture) and fluxes (e.g., latent heat flux). The EnKF method is shown to have less impact overall than the DI method and causes less distortion of the hydrological budget. However, the land surface model adjusts more slowly to the smaller EnKF increments, which leads to smaller but slightly more persistent moisture budget errors than found with the DI updates. The DI method can remove almost instantly much of the modeled snowpack, but this also allows the model system to quickly revert to hydrological balance for nonsnowpack conditions.
Methods for sample size determination in cluster randomized trials
Rutterford, Clare; Copas, Andrew; Eldridge, Sandra
2015-01-01
Background: The use of cluster randomized trials (CRTs) is increasing, along with the variety in their design and analysis. The simplest approach for their sample size calculation is to calculate the sample size assuming individual randomization and inflate this by a design effect to account for randomization by cluster. The assumptions of a simple design effect may not always be met; alternative or more complicated approaches are required. Methods: We summarise a wide range of sample size methods available for cluster randomized trials. For those familiar with sample size calculations for individually randomized trials but with less experience in the clustered case, this manuscript provides formulae for a wide range of scenarios with associated explanation and recommendations. For those with more experience, comprehensive summaries are provided that allow quick identification of methods for a given design, outcome and analysis method. Results: We present first those methods applicable to the simplest two-arm, parallel group, completely randomized design followed by methods that incorporate deviations from this design such as: variability in cluster sizes; attrition; non-compliance; or the inclusion of baseline covariates or repeated measures. The paper concludes with methods for alternative designs. Conclusions: There is a large amount of methodology available for sample size calculations in CRTs. This paper gives the most comprehensive description of published methodology for sample size calculation and provides an important resource for those designing these trials. PMID:26174515
Modification and identification of a vector for making a large phage antibody library.
Zhang, Guo-min; Chen, Yü-ping; Guan, Yuan-zhi; Wang, Yan; An, Yun-qing
2007-11-20
The large phage antibody library is used to obtain high-affinity human antibody, and the Loxp/cre site-specific recombination system is a potential method for constructing a large phage antibody library. In the present study, a phage antibody library vector pDF was reconstructed to construct diabody more quickly and conveniently without injury to homologous recombination and the expression function of the vector and thus to integrate construction of the large phage antibody library with the preparation of diabodies. scFv was obtained by overlap polymerase chain reaction (PCR) amplification with the newly designed VL and VH extension primers. loxp511 was flanked by VL and VH and the endonuclease ACC III encoding sequences were introduced on both sides of loxp511. scFv was cloned into the vector pDF to obtain the vector pDscFv. The vector expression function was identified and the feasibility of diabody preparation was evaluated. A large phage antibody library was constructed in pDscFv. Several antigens were used to screen the antibody library and the quality of the antibody library was evaluated. The phage antibody library expression vector pDscFv was successfully constructed and confirmed to express functional scFv. The large phage antibody library constructed using this vector was of high diversity. Screening of the library on 6 antigens confirmed the generation of specific antibodies to these antigens. Two antibodies were subjected to enzymatic digestion and were prepared into diabody with functional expression. The reconstructed vector pDscFv retains its recombination capability and expression function and can be used to construct large phage antibody libraries. It can be used as a convenient and quick method for preparing diabodies after simple enzymatic digestion, which facilitates clinical trials and application of antibody therapy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wagar, M; Friesen, S; Lyatskaya, Y
2016-06-15
Purpose: A daily QA device is used to monitor output, flatness and symmetry constancy for all linac photon and electron energies. If large deviations from baseline in flatness or symmetry are reported it becomes necessary to crosscheck the measurements with a second device. Setting up another device such as Matrixx (IBA Dosimetry) can be time consuming, due to its warm-up time, and trained personnel may not be readily available to analyze the results. Furthermore, this discrepancy is frequently isolated to a single energy. Unaffected energies could still be used, avoiding further patient delays, if a method to gather data formore » offline analysis could be developed. We find that optically stimulated luminescent dosimeters (OSLDs) provide a quick, simple, and inexpensive solution to this important clinical problem. Methods: The exact geometry of the detectors on the daily tracker (Keithley Therapy Beam Evaluator) was reproduced by placing nanoDot OSLDs (Landauer) on a solid water phantom. A combination of bolus and solid water was placed on top to provide buildup and prevent air gaps. Standard daily measurements of output, flatness and symmetry were taken for 2 photon energies (6x,10x) and 5 electron energies (6e,9e,12e,15e,18e) using the tracker. These measurements were then repeated with the OSLD phantom. Results: The time it took to set up the OSLD phantom was comparable to that of the tracker. The inline and crossline OSLD phantom measurements of flatness and symmetry agreed with the tracker results to within 2%. Conclusion: OSLDs provide a good solution for a quick second check when questionable flatness and symmetry results are detected with the tracker during daily QA.« less
Xu, Zhenqiang; Shen, Fangxia; Li, Xiaoguang; Wu, Yan; Chen, Qi; Jie, Xu; Yao, Maosheng
2012-01-01
Exhaled breath condensate (EBC) is increasingly being used as a non-invasive method for disease diagnosis and environmental exposure assessment. By using hydrophobic surface, ice, and droplet scavenging, a simple impaction and condensing based collection method is reported here. Human subjects were recruited to exhale toward the device for 1, 2, 3, and 4 min. The exhaled breath quickly formed into tiny droplets on the hydrophobic surface, which were subsequently scavenged into a 10 µL rolling deionized water droplet. The collected EBC was further analyzed using culturing, DNA stain, Scanning Electron Microscope (SEM), polymerase chain reaction (PCR) and colorimetry (VITEK 2) for bacteria and viruses. Experimental data revealed that bacteria and viruses in EBC can be rapidly collected using the method developed here, with an observed efficiency of 100 µL EBC within 1 min. Culturing, DNA stain, SEM, and qPCR methods all detected high bacterial concentrations up to 7000 CFU/m3 in exhaled breath, including both viable and dead cells of various types. Sphingomonas paucimobilis and Kocuria variants were found dominant in EBC samples using VITEK 2 system. SEM images revealed that most bacteria in exhaled breath are detected in the size range of 0.5–1.0 µm, which is able to enable them to remain airborne for a longer time, thus presenting a risk for airborne transmission of potential diseases. Using qPCR, influenza A H3N2 viruses were also detected in one EBC sample. Different from other devices restricted solely to condensation, the developed method can be easily achieved both by impaction and condensation in a laboratory and could impact current practice of EBC collection. Nonetheless, the reported work is a proof-of-concept demonstration, and its performance in non-invasive disease diagnosis such as bacterimia and virus infections needs to be further validated including effects of its influencing matrix. PMID:22848436
Schulze, H Georg; Turner, Robin F B
2013-04-01
Raman spectra often contain undesirable, randomly positioned, intense, narrow-bandwidth, positive, unidirectional spectral features generated when cosmic rays strike charge-coupled device cameras. These must be removed prior to analysis, but doing so manually is not feasible for large data sets. We developed a quick, simple, effective, semi-automated procedure to remove cosmic ray spikes from spectral data sets that contain large numbers of relatively homogenous spectra. Although some inhomogeneous spectral data sets can be accommodated--it requires replacing excessively modified spectra with the originals and removing their spikes with a median filter instead--caution is advised when processing such data sets. In addition, the technique is suitable for interpolating missing spectra or replacing aberrant spectra with good spectral estimates. The method is applied to baseline-flattened spectra and relies on fitting a third-order (or higher) polynomial through all the spectra at every wavenumber. Pixel intensities in excess of a threshold of 3× the noise standard deviation above the fit are reduced to the threshold level. Because only two parameters (with readily specified default values) might require further adjustment, the method is easily implemented for semi-automated processing of large spectral sets.
Sahu, Nidhi; Soni, Deepika; Chandrashekhar, B; Sarangi, Bijaya Ketan; Satpute, Devanand; Pandey, Ram Avatar
2013-07-01
Many methods of synthesizing silver nanoparticles (Ag-NPs) by reducing Ag⁺ ions using aqueous/organic extracts of various plants have been reported in the past, but the methods are rather slow. In this investigation, silver nanoparticles were quickly synthesized from aqueous silver nitrate through a simple method using leaf extract of a plant--Cynodon dactylon which served as reducing agent, while sunlight acted as a catalyst. The formation of Ag-NPs was indicated by gradual change in colour and pH and confirmed by ultraviolet--visible spectroscopy. The Ag-NPs showed a surface plasmon resonance at 451 nm. Based on the decrease in pH, a possible mechanism of the synthesis of Ag-NPs involving hydroxyl (OH⁻) ions of polyphenols of the leaf extract is postulated. Ag-NPs having (111) and (200) crystal lattices were confirmed by X-ray diffraction. Scanning electron microscopy revealed the spherical nature of the Ag-NPs, while transmission electron microscopy showed that the nanoparticles were polydispersed with a size range of 8-10 nm. The synthesized Ag-NPs also demonstrated their antibacterial activity against Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus and Salmonella typhimurium.
Messerli, Mark A.; Collis, Leon P.; Smith, Peter J.S.
2009-01-01
Previously, functional mapping of channels has been achieved by measuring the passage of net charge and of specific ions with electrophysiological and intracellular fluorescence imaging techniques. However, functional mapping of ion channels using extracellular ion-selective microelectrodes has distinct advantages over the former methods. We have developed this method through measurement of extracellular K+ gradients caused by efflux through Ca2+-activated K+ channels expressed in Chinese hamster ovary cells. We report that electrodes constructed with short columns of a mechanically stable K+-selective liquid membrane respond quickly and measure changes in local [K+] consistent with a diffusion model. When used in close proximity to the plasma membrane (<4 μm), the ISMs pose a barrier to simple diffusion, creating an ion trap. The ion trap amplifies the local change in [K+] without dramatically changing the rise or fall time of the [K+] profile. Measurement of extracellular K+ gradients from activated rSlo channels shows that rapid events, 10–55 ms, can be characterized. This method provides a noninvasive means for functional mapping of channel location and density as well as for characterizing the properties of ion channels in the plasma membrane. PMID:19217875
Xu, Jiao-Jiao; Zhou, Jian; Huang, Bai-Fen; Cai, Zeng-Xuan; Xu, Xiao-Min; Ren, Yi-Ping
2016-06-01
A simple and reliable method of ultra high performance liquid chromatography coupled with photo-diode array detection has been proposed for the simultaneous determination of deoxynivalenol and its acetylated derivatives in wheat flour and rice, especially focusing on the optimization of sample extraction, cleanup, and chromatographic separation conditions. Sample pretreatment consisted of a first step using a quick, easy, cheap, effective, rugged, and safe based extraction procedure and a subsequent cleanup step based on solid-phase extraction. The method was extensively validated in wheat flour and rice, obtaining satisfactory analytical performance with good linearity (R(2) ≥ 0.999), acceptable recoveries (80.0-104.4%), and repeatability (RSDs 1.3-10.7%). The limits of detection (21.7-57.4 μg/kg) and quantitation (72.3-191.4 μg/kg) for deoxynivalenols were lower than those usually permitted by various countries' legislation in these food matrices. The method was applied to 34 wheat and rice samples. The results were further compared with results of ultra high performance liquid chromatography with electrospray ionization tandem mass spectrometry. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Boggia, Raffaella; Casolino, Maria Chiara; Hysenaj, Vilma; Oliveri, Paolo; Zunin, Paola
2013-10-15
Consumer demand for pomegranate juice has considerably grown, during the last years, for its potential health benefits. Since it is an expensive functional food, cheaper fruit juices addition (i.e., grape and apple juices) or its simple dilution, or polyphenols subtraction are deceptively used. At present, time-consuming analyses are used to control the quality of this product. Furthermore these analyses are expensive and require well-trained analysts. Thus, the purpose of this study was to propose a high-speed and easy-to-use shortcut. Based on UV-VIS spectroscopy and chemometrics, a screening method is proposed to quickly screening some common fillers of pomegranate juice that could decrease the antiradical scavenging capacity of pure products. The analytical method was applied to laboratory prepared juices, to commercial juices and to representative experimental mixtures at different levels of water and filler juices. The outcomes were evaluated by means of multivariate exploratory analysis. The results indicate that the proposed strategy can be a useful screening tool to assess addition of filler juices and water to pomegranate juices. Copyright © 2012 Elsevier Ltd. All rights reserved.
Kamioka, Hiroharu; Kawamura, Yoichi; Tsutani, Kiichiro; Maeda, Masaharu; Hayasaka, Shinya; Okuizum, Hiroyasu; Okada, Shinpei; Honda, Takuya; Iijima, Yuichi
2013-08-01
The purpose of this study was to develop a checklist of items that describes and measures the quality of reports of interventional trials assessing spa therapy. The Delphi consensus method was used to select the number of items in the checklist. A total of eight individuals participated, including an epidemiologist, a clinical research methodologist, clinical researchers, a medical journalist, and a health fitness programmer. Participants ranked on a 9-point Likert scale whether an item should be included in the checklist. Three rounds of the Delphi method were conducted to achieve consensus. The final checklist contained 19 items, with items related to title, place of implementation (specificity of spa), care provider influence, and additional measures to minimize the potential bias from withdrawals, loss to follow-up, and low treatment adherence. This checklist is simple and quick to complete, and should help clinicians and researchers critically appraise the medical and healthcare literature, reviewers assess the quality of reports included in systematic reviews, and researchers plan interventional trials of spa therapy. Copyright © 2013 Elsevier Ltd. All rights reserved.
Towards autonomous neuroprosthetic control using Hebbian reinforcement learning.
Mahmoudi, Babak; Pohlmeyer, Eric A; Prins, Noeline W; Geng, Shijia; Sanchez, Justin C
2013-12-01
Our goal was to design an adaptive neuroprosthetic controller that could learn the mapping from neural states to prosthetic actions and automatically adjust adaptation using only a binary evaluative feedback as a measure of desirability/undesirability of performance. Hebbian reinforcement learning (HRL) in a connectionist network was used for the design of the adaptive controller. The method combines the efficiency of supervised learning with the generality of reinforcement learning. The convergence properties of this approach were studied using both closed-loop control simulations and open-loop simulations that used primate neural data from robot-assisted reaching tasks. The HRL controller was able to perform classification and regression tasks using its episodic and sequential learning modes, respectively. In our experiments, the HRL controller quickly achieved convergence to an effective control policy, followed by robust performance. The controller also automatically stopped adapting the parameters after converging to a satisfactory control policy. Additionally, when the input neural vector was reorganized, the controller resumed adaptation to maintain performance. By estimating an evaluative feedback directly from the user, the HRL control algorithm may provide an efficient method for autonomous adaptation of neuroprosthetic systems. This method may enable the user to teach the controller the desired behavior using only a simple feedback signal.
Fang, Te; Andrews, Susan A; Hofmann, Ron
2017-05-01
A simple and quick method to measure sucralose in aqueous solution at concentrations in the order of 0.1-1.2 g·L-1 proposed by Idris et al. uses UV irradiation prior to UV spectrophotometry. The photolysis of sucralose forms a photoactive compound characterized by maximum absorbance at approximately 270 nm. The conditions required for sucralose photolysis, however, had not been completely reported. In this work, the procedure described by Idris et al. was replicated using a low-pressure UV lamp to irradiate sucralose samples with a wider range of initial concentrations (0.04-10 g·L-1) with known fluences. It was determined that care must be taken to ensure that the same fluence is applied for both calibration and measurement steps because the absorbance of the sucralose photolysis product is a function of the applied fluence. The way the samples are irradiated also has an impact on the results in that the method exhibits a greater linear range if an apparatus is used that maximizes the fluence rate (e.g., by placing samples closer to the UV source or using a higher-intensity lamp).
Jan, Ishrat; Dar, Alamgir A; Mubashir, Sofi; Alam Wani, Ashraf; Mukhtar, Malik; Sofi, Khurshid A; Dar, Irshad H; Sofi, Javid A
2018-05-01
Residue investigation was carried out to scrutinize the persistence, dissipation behavior, half-life, and risk assessment of ethion on green pea fruit by spraying ethion at the fruiting stage followed by another application at 10 day intervals. The samples were extracted by using a quick, easy, low-cost, effective, rugged, and safe method, and the residues of ethion were analyzed by gas chromatography with electron capture detection. Here we report a novel, accurate, and cost-effective gas chromatography method for the determination of average deposits of ethion on green pea. The initial deposits were found to be 4.65 mg/kg following the application of insecticide. Residues of ethion reached below the detection limit of 0.10 mg/kg after 25 days at recommended dosage. The half-life of ethion was found to be 4.62 days. For risk assessment studies, the 25th day will be safe for consumers for the consumption of green peas. The developed method is simple, sensitive, selective, and repeatable and can be extended for ethion-based standardization of herbal formulations containing green pea and its use in pesticide industries. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Dar, Alamgir A; Jan, Ishrat; Wani, Ashraf A; Mubashir, Sofi; Sofi, Khurshid A; Sofi, Javid A; Dar, Irshad H
2018-06-01
Chemical investigation was carried out to examine the risk assessment, dissipation behavior, persistence, and half-life period of quinalphos in/on green pea fruit by spraying quinalphos at fruiting stage followed by another application after 10-day interval. The samples were extracted by using the quick, easy, cheap, effective, rugged, and safe method, and the residues of quinalphos were analyzed by gas chromatography with electron capture detector. Herein, we report a novel, accurate, and cost-effective gas chromatography method for the determination of average deposits of quinalphos in/on green pea. The initial deposits and half-life of quinalphos were found to be 1.20 mg/kg and 2.77 days, respectively, following the application of insecticide. Residues of quinalphos reached below detection limit of 0.05 mg/kg after 10 days at recommended dosage. For risk assessment studies, the tenth day will be safe for consumers for consumption of green pea. The developed method is simple, selective, and repeatable, and it can be extended for quinalphos-based standardization of herbal formulations containing green pea and its use in pesticide industries. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ma, Jianshe; Cai, Jinzhang; Lin, Guanyang; Chen, Huilin; Wang, Xianqin; Wang, Xianchuan; Hu, Lufeng
2014-05-15
Corynoxeine(CX), isolated from the extract of Uncaria rhynchophylla, is a useful and prospective compound in the prevention and treatment for vascular diseases. A simple and selective liquid chromatography mass spectrometry (LC-MS) method was developed to determine the concentration of CX in rat plasma. The chromatographic separation was achieved on a Zorbax SB-C18 (2.1 mm × 150 mm, 5 μm) column with acetonitrile-0.1% formic acid in water as mobile phase. Selective ion monitoring (SIM) mode was used for quantification using target ions m/z 383 for CX and m/z 237 for the carbamazepine (IS). After the LC-MS method was validated, it was applied to a back-propagation artificial neural network (BP-ANN) pharmacokinetic model study of CX in rats. The results showed that after intravenous administration of CX, it was mainly distributed in blood and eliminated quickly, t1/2 was less than 1h. The predicted concentrations generated by BP-ANN model had a high correlation coefficient (R>0.99) with experimental values. The developed BP-ANN pharmacokinetic model can be used to predict the concentration of CX in rats. Copyright © 2014 Elsevier B.V. All rights reserved.
Indexing Mount For Rotation Of Optical Component
NASA Technical Reports Server (NTRS)
Reichle, Donald J., Jr.; Barnes, Norman P.
1993-01-01
Indexing mount for polarizer, wave plate, birefringent plate, or other optical component facilitates rotation of component to one or more preset angles. Includes hexagonal nut holding polarizer or other optical component. Ball bearing loaded by screw engages notch on cylindrical extension of nut engaging bracket. Time-consuming and tedious angular adjustment unnecessary: component turned quickly and easily, by hand or by use of wrench, to preset angular positions maintained by simple ball-detent mechanism.
Auxiliary variables for numerically solving nonlinear equations with softly broken symmetries.
Olum, Ken D; Masoumi, Ali
2017-06-01
General methods for solving simultaneous nonlinear equations work by generating a sequence of approximate solutions that successively improve a measure of the total error. However, if the total error function has a narrow curved valley, the available techniques tend to find the solution after a very large number of steps, if ever. The solver first converges rapidly to the valley, but once there it converges extremely slowly to the solution. In this paper we show that in the specific physically important case where these valleys are the result of a softly broken symmetry, the solution can often be found much more quickly by adding the generators of the softly broken symmetry as auxiliary variables. This makes the number of variables more than the equations and hence there will be a family of solutions, any one of which would be acceptable. We present a procedure for finding solutions in this case and apply it to several simple examples and an important problem in the physics of false vacuum decay. We also provide a Mathematica package that implements Powell's hybrid method with the generalization to allow more variables than equations.
Tian, Ting-Ting; Ma, Ying-Hua; Xie, Wei-Wei; Jin, Yi-Ran; Xu, Hui-Jun; Zhang, Lan-Tong; Du, Ying-Feng
2016-01-01
A quick HPLC-ESI-MS/MS method was established for simultaneous determination of four major diterpenoids in Rabdosia japonica var.glaucocalyx, including glaucocalyxin A, oridonin, hebeirubesensin and enmenol. Analysis was performed on an Agilent ZORBAX SB-C18(4.6 mm×250 mm, 5 μm ) column eluted in a gradient program with methanol and water. The flow rate was 0.8 mL•min⁻¹. Multiple reaction monitoring (MRM) scanning mode was performed in negative ion switching mode to apply for the quantitative determination. The calibration curves for the above four compounds were linear in corresponding injection amount. The average recoveries of the compounds ranged from 92.40% to 105.9%, with RSDs of 1.7%-6.5%. The method is simple, rapid, accurate with good repeatability, which can provide a reference for overcalling evaluation the quality of R. japonica var.glaucocalyx. The result of cluster analysis- showed that the quality of R. japonica glaucocalyx var. greatly varied between areas and parts. Copyright© by the Chinese Pharmaceutical Association.
Nakano, Sachie; Tsukimura, Takahiro; Togawa, Tadayasu; Ohashi, Toya; Kobayashi, Masahisa; Takayama, Katsuyoshi; Kobayashi, Yukuharu; Abiko, Hiroshi; Satou, Masatsugu; Nakahata, Tohru; Warnock, David G; Sakuraba, Hitoshi; Shibasaki, Futoshi
2015-01-01
We developed an immunochromatography-based assay for detecting antibodies against recombinant α-galactosidase A proteins in serum. The evaluation of 29 serum samples from Fabry patients, who had received enzyme replacement therapy with agalsidase alpha and/or agalsidase beta, was performed by means of this assay method, and the results clearly revealed that the patients exhibited the same level of antibodies against both agalsidase alpha and agalsidase beta, regardless of the species of recombinant α-galactosidase A used for enzyme replacement therapy. A conventional enzyme-linked immunosorbent assay supported the results. Considering these, enzyme replacement therapy with agalsidase alpha or agalsidase beta would generate antibodies against the common epitopes in both agalsidase alpha and agalsidase beta. Most of the patients who showed immunopositive reaction exhibited classic Fabry phenotype and harbored gene mutations affecting biosynthesis of α-galactosidase A. As immunochromatography is a handy and simple assay system which can be available at bedside, this assay method would be extremely useful for quick evaluation or first screening of serum antibodies against agalsidase alpha or agalsidase beta in Fabry disease with enzyme replacement therapy.
Surgical Removal of Neglected Soft Tissue Foreign Bodies by Needle-Guided Technique
Ebrahimi, Ali; Radmanesh, Mohammad; Rabiei, Sohrab; kavoussi, Hossein
2013-01-01
Introduction: The phenomenon of neglected foreign bodies is a significant cause of morbidity in soft tissue injuries and may present to dermatologists as delayed wound healing, localized cellulitis and inflammation, abscess formation, or foreign body sensation. Localization and removal of neglected soft tissue foreign bodies (STFBs) is complex due to possible inflammation, indurations, granulated tissue, and fibrotic scar. This paper describes a simple method for the quick localization and (surgical) removal of neglected STFBs using two 23-gauge needles without ultrasonographic or fluoroscopic guidance. Materials and Methods: A technique based on the use of two 23-gauge needles was used in 41 neglected STFBs in order to achieve proper localization and fixation of foreign bodies during surgery. Results: Surgical removal was successful in 38 of 41 neglected STFBs (ranging from 2–13mm in diameter). Conclusion: The cross-needle-guided technique is an office-based procedure that allows the successful surgical removal of STFBs using minimal soft tissue exploration and dissection via proper localization, fixation, and propulsion of the foreign body toward the surface of the skin. PMID:24303416
Nanosized zeolites as a perspective material for conductometric biosensors creation
NASA Astrophysics Data System (ADS)
Kucherenko, Ivan; Soldatkin, Oleksandr; Kasap, Berna Ozansoy; Kirdeciler, Salih Kaan; Kurc, Burcu Akata; Jaffrezic-Renault, Nicole; Soldatkin, Alexei; Lagarde, Florence; Dzyadevych, Sergei
2015-05-01
In this work, the method of enzyme adsorption on different zeolites and mesoporous silica spheres (MSS) was investigated for the creation of conductometric biosensors. The conductometric transducers consisted of gold interdigitated electrodes were placed on the ceramic support. The transducers were modified with zeolites and MSS, and then the enzymes were adsorbed on the transducer surface. Different methods of zeolite attachment to the transducer surface were used; drop coating with heating to 200°C turned out to be the best one. Nanozeolites beta and L, zeolite L, MSS, and silicalite-1 (80 to 450 nm) were tested as the adsorbents for enzyme urease. The biosensors with all tested particles except zeolite L had good analytical characteristics. Silicalite-1 (450 nm) was also used for adsorption of glucose oxidase, acetylcholinesterase, and butyrylcholinesterase. The glucose and acetylcholine biosensors were successfully created, whereas butyrylcholinesterase was not adsorbed on silicalite-1. The enzyme adsorption on zeolites and MSS is simple, quick, well reproducible, does not require use of toxic compounds, and therefore can be recommended for the development of biosensors when these advantages are especially important.
Reproducibility of electronic tooth colour measurements.
Ratzmann, Anja; Klinke, Thomas; Schwahn, Christian; Treichel, Anja; Gedrange, Tomasz
2008-10-01
Clinical methods of investigation, such as tooth colour determination, should be simple, quick and reproducible. The determination of tooth colours usually relies upon manual comparison of a patient's tooth colour with a colour ring. After some days, however, measurement results frequently lack unequivocal reproducibility. This study aimed to examine an electronic method for reliable colour measurement. The colours of the teeth 14 to 24 were determined by three different examiners in 10 subjects using the colour measuring device Shade Inspector. In total, 12 measurements per tooth were taken. Two measurement time points were scheduled to be taken, namely at study onset (T(1)) and after 6 months (T(2)). At either time point, two measurement series per subject were taken by the different examiners at 2-week intervals. The inter-examiner and intra-examiner agreement of the measurement results was assessed. The concordance for lightness and colour intensity (saturation) was represented by the intra-class correlation coefficient. The categorical variable colour shade (hue) was assessed using the kappa statistic. The study results show that tooth colour can be measured independently of the examiner. Good agreement was found between the examiners.
Paracousti-UQ: A Stochastic 3-D Acoustic Wave Propagation Algorithm.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Preston, Leiph
Acoustic full waveform algorithms, such as Paracousti, provide deterministic solutions in complex, 3-D variable environments. In reality, environmental and source characteristics are often only known in a statistical sense. Thus, to fully characterize the expected sound levels within an environment, this uncertainty in environmental and source factors should be incorporated into the acoustic simulations. Performing Monte Carlo (MC) simulations is one method of assessing this uncertainty, but it can quickly become computationally intractable for realistic problems. An alternative method, using the technique of stochastic partial differential equations (SPDE), allows computation of the statistical properties of output signals at a fractionmore » of the computational cost of MC. Paracousti-UQ solves the SPDE system of 3-D acoustic wave propagation equations and provides estimates of the uncertainty of the output simulated wave field (e.g., amplitudes, waveforms) based on estimated probability distributions of the input medium and source parameters. This report describes the derivation of the stochastic partial differential equations, their implementation, and comparison of Paracousti-UQ results with MC simulations using simple models.« less
Mei, Chenghan; Li, Bin; Yin, Qiangfeng; Jin, Jing; Xiong, Ting; He, Wenjuan; Gao, Xiujuan; Xu, Rong; Zhou, Piqi; Zheng, Heng; Chen, Hui
2015-07-01
A simple, quick and accurate LC-MS/MS method for the quantification of flurbiprofen in human plasma with indomethacin as internal standard (IS) was developed and validated. Samples were treated with methanol to precipitate proteins, then separated on a Ultimate C18 column (5μm, 2.1×50mm) with a gradient elusion process. Mobile phase A was comprised of water and formic acid, mobile phase B was comprised of acetonitrile and formic acid. Multi reaction monitoring (MRM) signals were saved on a negative ionization electrospray mass spectrometer. The calibration curve showed good linearity in the range of 40.00-10000.00μg/L (r(2)=0.998). Intra-day RE was 0.2-2.2%. Inter-day RE was 0.5-3.4%. The samples showed good stability under the study conditions. No significant matrix effect was observed. The established method was then applied to a bioequivalence study of a flurbiprofen axetil formulation. Copyright © 2015 Elsevier B.V. All rights reserved.
Saha, Suman; Majumder, Sambrita; Das, Sushovan; Das, Tapan Kumar; Bhattacharyya, Anjan; Roy, Sankhajit
2018-04-01
A laboratory experiment was conducted to investigate the effect of pH on the persistence and the dissipation of the new readymix formulation of bispyribac sodium and metamifop. The experiment was conducted in water of three different pH viz. 4.0, 7.0 and 9.2. The spiking level of both the compounds in water was 1.0 and 2.0 µg/mL. The residues were extracted by a simple, quick and reliable method and quantified by liquid chromatography tandem mass spectrometry (LC-MS/MS). The method was justified based on the recovery study, which was > 85%. The dissipation of both compounds followed first order kinetics. The half-life values ranged between 19.86-36.29 and 9.92-19.69 days for bispyribac sodium and metamifop, respectively. The pH of water has a prominent effect on degradation of both the compounds. The rate of dissipation of both the compounds was highest in water of acidic pH followed by neutral and alkaline pH.
Detection of timescales in evolving complex systems
Darst, Richard K.; Granell, Clara; Arenas, Alex; Gómez, Sergio; Saramäki, Jari; Fortunato, Santo
2016-01-01
Most complex systems are intrinsically dynamic in nature. The evolution of a dynamic complex system is typically represented as a sequence of snapshots, where each snapshot describes the configuration of the system at a particular instant of time. This is often done by using constant intervals but a better approach would be to define dynamic intervals that match the evolution of the system’s configuration. To this end, we propose a method that aims at detecting evolutionary changes in the configuration of a complex system, and generates intervals accordingly. We show that evolutionary timescales can be identified by looking for peaks in the similarity between the sets of events on consecutive time intervals of data. Tests on simple toy models reveal that the technique is able to detect evolutionary timescales of time-varying data both when the evolution is smooth as well as when it changes sharply. This is further corroborated by analyses of several real datasets. Our method is scalable to extremely large datasets and is computationally efficient. This allows a quick, parameter-free detection of multiple timescales in the evolution of a complex system. PMID:28004820
Wang, Monan; Zhang, Kai; Yang, Ning
2018-04-09
To help doctors decide their treatment from the aspect of mechanical analysis, the work built a computer assisted optimal system for treatment of femoral neck fracture oriented to clinical application. The whole system encompassed the following three parts: Preprocessing module, finite element mechanical analysis module, post processing module. Preprocessing module included parametric modeling of bone, parametric modeling of fracture face, parametric modeling of fixed screw and fixed position and input and transmission of model parameters. Finite element mechanical analysis module included grid division, element type setting, material property setting, contact setting, constraint and load setting, analysis method setting and batch processing operation. Post processing module included extraction and display of batch processing operation results, image generation of batch processing operation, optimal program operation and optimal result display. The system implemented the whole operations from input of fracture parameters to output of the optimal fixed plan according to specific patient real fracture parameter and optimal rules, which demonstrated the effectiveness of the system. Meanwhile, the system had a friendly interface, simple operation and could improve the system function quickly through modifying single module.
Optimal current waveforms for brushless permanent magnet motors
NASA Astrophysics Data System (ADS)
Moehle, Nicholas; Boyd, Stephen
2015-07-01
In this paper, we give energy-optimal current waveforms for a permanent magnet synchronous motor that result in a desired average torque. Our formulation generalises previous work by including a general back-electromotive force (EMF) wave shape, voltage and current limits, an arbitrary phase winding connection, a simple eddy current loss model, and a trade-off between power loss and torque ripple. Determining the optimal current waveforms requires solving a small convex optimisation problem. We show how to use the alternating direction method of multipliers to find the optimal current in milliseconds or hundreds of microseconds, depending on the processor used, which allows the possibility of generating optimal waveforms in real time. This allows us to adapt in real time to changes in the operating requirements or in the model, such as a change in resistance with winding temperature, or even gross changes like the failure of one winding. Suboptimal waveforms are available in tens or hundreds of microseconds, allowing for quick response after abrupt changes in the desired torque. We demonstrate our approach on a simple numerical example, in which we give the optimal waveforms for a motor with a sinusoidal back-EMF, and for a motor with a more complicated, nonsinusoidal waveform, in both the constant-torque region and constant-power region.
Henderson, Fraser; Takacs, Istvan
2017-01-01
Troubleshooting of deep brain stimulators (DBSs, Activa SC/PC/RC Medtronic PLC, Minneapolis, Minnesota, USA) sometimes results in a decision to replace a tunneled stretch-coil extension cable. We present a simple technique to accomplish this atraumatically without a tunneling tool. In the treatment of patients with a DBS, complication avoidance and efficiency of operative time are paramount. We sought to find the safest, most effective, and fastest method of performing the conceptually simple yet technically nuanced act of replacing lead extension cables. We connected #6 (8.0 metric) surgical steel 18″ (45-cm) monofilament (Ethicon US, LLC, Somerville, New Jersey, USA), also known as #6 sternal wire, in line with DBS extension cables (Medtronic DBS Extension 37086-60) in novel fashion to overcome intraprocedural hurdles encountered during the past decade in a busy functional neurosurgery service. Patients tolerate the procedure well and return home shortly after recovery with no complications. A less expensive and faster technique for passing pulse generator extension cables may be the use of a sternal wire. Using the described technique, pulse generators may be quickly and safely adjusted from side to side and site to site as the clinical situation dictates. Copyright © 2016 Elsevier Inc. All rights reserved.
Smith, Douglas D.; Hiller, John M.
1998-01-01
The present invention is an improved method and related apparatus for quantitatively analyzing machine working fluids and other aqueous compositions such as wastewater which contain various mixtures of cationic, neutral, and/or anionic surfactants, soluble soaps, and the like. The method utilizes a single-phase, non-aqueous, reactive titration composition containing water insoluble bismuth nitrate dissolved in glycerol for the titration reactant. The chemical reaction of the bismuth ion and glycerol with the surfactant in the test solutions results in formation of micelles, changes in micelle size, and the formation of insoluble bismuth soaps. These soaps are quantified by physical and chemical changes in the aqueous test solution. Both classical potentiometric analysis and turbidity measurements have been used as sensing techniques to determine the quantity of surfactant present in test solutions. This method is amenable to the analysis of various types of new, in-use, dirty or decomposed surfactants and detergents. It is a quick and efficient method utilizing a single-phase reaction without needing a separate extraction from the aqueous solution. It is adaptable to automated control with simple and reliable sensing methods. The method is applicable to a variety of compositions with concentrations from about 1% to about 10% weight. It is also applicable to the analysis of waste water containing surfactants with appropriate pre-treatments for concentration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, D.D.; Hiller, J.M.
1998-02-24
The present invention is an improved method and related apparatus for quantitatively analyzing machine working fluids and other aqueous compositions such as wastewater which contain various mixtures of cationic, neutral, and/or anionic surfactants, soluble soaps, and the like. The method utilizes a single-phase, non-aqueous, reactive titration composition containing water insoluble bismuth nitrate dissolved in glycerol for the titration reactant. The chemical reaction of the bismuth ion and glycerol with the surfactant in the test solutions results in formation of micelles, changes in micelle size, and the formation of insoluble bismuth soaps. These soaps are quantified by physical and chemical changesmore » in the aqueous test solution. Both classical potentiometric analysis and turbidity measurements have been used as sensing techniques to determine the quantity of surfactant present in test solutions. This method is amenable to the analysis of various types of new, in-use, dirty or decomposed surfactants and detergents. It is a quick and efficient method utilizing a single-phase reaction without needing a separate extraction from the aqueous solution. It is adaptable to automated control with simple and reliable sensing methods. The method is applicable to a variety of compositions with concentrations from about 1% to about 10% weight. It is also applicable to the analysis of waste water containing surfactants with appropriate pre-treatments for concentration. 1 fig.« less
Smith, D.D.; Hiller, J.M.
1998-02-24
The present invention is an improved method and related apparatus for quantitatively analyzing machine working fluids and other aqueous compositions such as wastewater which contain various mixtures of cationic, neutral, and/or anionic surfactants, soluble soaps, and the like. The method utilizes a single-phase, non-aqueous, reactive titration composition containing water insoluble bismuth nitrate dissolved in glycerol for the titration reactant. The chemical reaction of the bismuth ion and glycerol with the surfactant in the test solutions results in formation of micelles, changes in micelle size, and the formation of insoluble bismuth soaps. These soaps are quantified by physical and chemical changes in the aqueous test solution. Both classical potentiometric analysis and turbidity measurements have been used as sensing techniques to determine the quantity of surfactant present in test solutions. This method is amenable to the analysis of various types of new, in-use, dirty or decomposed surfactants and detergents. It is a quick and efficient method utilizing a single-phase reaction without needing a separate extraction from the aqueous solution. It is adaptable to automated control with simple and reliable sensing methods. The method is applicable to a variety of compositions with concentrations from about 1% to about 10% weight. It is also applicable to the analysis of waste water containing surfactants with appropriate pre-treatments for concentration. 1 fig.
Quickly Approximating the Distance Between Two Objects
NASA Technical Reports Server (NTRS)
Hammen, David
2009-01-01
A method of quickly approximating the distance between two objects (one smaller, regarded as a point; the other larger and complexly shaped) has been devised for use in computationally simulating motions of the objects for the purpose of planning the motions to prevent collisions.
Morales, Álvaro J Ruiz
2012-01-01
To communicate effectively during a lecture or presentation it is necessary to follow simple rules, including the preparation of the conference with the audience in mind and with the definition of a specific message to leave the audience. The public's attention should be quickly captured and all subsequent actions should aim to keep it. The text must be accurate and sizes easily visible, the slides should provide good contrast with solid and simple backgrounds and should avoid excessive animations. At the close of the conference, the conclusions and question session offers the invaluable opportunity to reinforce the desired message. Copyright © 2012 Asociación Colombiana de Psiquiatría. Publicado por Elsevier España. All rights reserved.
A Simple Technique for Securing Data at Rest Stored in a Computing Cloud
NASA Astrophysics Data System (ADS)
Sedayao, Jeff; Su, Steven; Ma, Xiaohao; Jiang, Minghao; Miao, Kai
"Cloud Computing" offers many potential benefits, including cost savings, the ability to deploy applications and services quickly, and the ease of scaling those application and services once they are deployed. A key barrier for enterprise adoption is the confidentiality of data stored on Cloud Computing Infrastructure. Our simple technique implemented with Open Source software solves this problem by using public key encryption to render stored data at rest unreadable by unauthorized personnel, including system administrators of the cloud computing service on which the data is stored. We validate our approach on a network measurement system implemented on PlanetLab. We then use it on a service where confidentiality is critical - a scanning application that validates external firewall implementations.
The slack test does not assess maximal shortening velocity of muscle fascicle in human.
Hager, Robin; Dorel, Sylvain; Nordez, Antoine; Rabita, Giuseppe; Couturier, Antoine; Hauraix, Hugo; Duchateau, Jacques; Guilhem, Gaël
2018-06-14
The application of a series of extremely high accelerative motor-driven quick releases while muscles contract isometrically (i.e. slack test) has been proposed to assess unloaded velocity in human muscle. This study aimed to measure gastrocnemius medialis fascicle (V F ) and tendinous tissues shortening velocity during motor-driven quick releases performed at various activation levels to assess the applicability of the slack test method in human. Maximal fascicle shortening velocity and joint velocity recorded during quick releases and during fast contraction without external load (ballistic condition) were compared. Gastrocnemius medialis fascicle behaviour was investigated from 25 participants using high-frame rate ultrasound during quick releases performed at various activation levels (from 0% to 60% of maximal voluntary isometric torque) and ballistic contractions. Unloaded joint velocity calculated using the slack test method increased whereas V F decreased with muscle activation level (P≤0.03). Passive and low-level quick releases elicited higher V F values (≥ 41.4±9.7 cm.s -1 ) compared to ballistic condition (36.3±8.7 cm.s -1 ), while quick releases applied at 60% of maximal voluntary isometric torque produced the lowest V F These findings suggest that initial fascicle length, complex fascicle-tendon interactions, unloading reflex and motor-driven movement pattern strongly influence and limit the shortening velocity achieved during the slack test. Furthermore, V F elicited by quick releases is likely to reflect substantial contributions of passive processes. Therefore, the slack test is not appropriate to assess maximal muscle shortening velocity in vivo. © 2018. Published by The Company of Biologists Ltd.
NASA Astrophysics Data System (ADS)
Ratner, Jacqueline; Pyle, David; Mather, Tamsin
2015-04-01
Structure-from-motion (SfM) techniques are now widely available to quickly and cheaply generate digital terrain models (DTMs) from optical imagery. Topography can change rapidly during disaster scenarios and change the nature of local hazards, making ground-based SfM a particularly useful tool in hazard studies due to its low cost, accessibility, and potential for immediate deployment. Our study is designed to serve as an analogue to potential real-world use of the SfM method if employed for disaster risk reduction purposes. Experiments at a volcanic crater in Santorini, Greece, used crowd-sourced data collection to demonstrate the impact of user expertise and randomization of SfM data on the resultant DTM. Three groups of participants representing variable expertise levels utilized 16 different camera models, including four camera phones, to collect 1001 total photos in one hour of data collection. Datasets collected by each group were processed using the free and open source software VisualSFM. The point densities and overall quality of the resultant SfM point clouds were compared against each other and also against a LiDAR dataset for reference to the industry standard. Our results show that the point clouds are resilient to changes in user expertise and collection method and are comparable or even preferable in data density to LiDAR. We find that 'crowd-sourced' data collected by a moderately informed general public yields topography results comparable to those produced with data collected by experts. This means that in a real-world scenario involving participants with a diverse range of expertise levels, topography models could be produced from crowd-sourced data quite rapidly and to a very high standard. This could be beneficial to disaster risk reduction as a relatively quick, simple, and low-cost method to attain a rapidly updated knowledge of terrain attributes, useful for the prediction and mitigation of many natural hazards.
Unified Geophysical Cloud Platform (UGCP) for Seismic Monitoring and other Geophysical Applications.
NASA Astrophysics Data System (ADS)
Synytsky, R.; Starovoit, Y. O.; Henadiy, S.; Lobzakov, V.; Kolesnikov, L.
2016-12-01
We present Unified Geophysical Cloud Platform (UGCP) or UniGeoCloud as an innovative approach for geophysical data processing in the Cloud environment with the ability to run any type of data processing software in isolated environment within the single Cloud platform. We've developed a simple and quick method of several open-source widely known software seismic packages (SeisComp3, Earthworm, Geotool, MSNoise) installation which does not require knowledge of system administration, configuration, OS compatibility issues etc. and other often annoying details preventing time wasting for system configuration work. Installation process is simplified as "mouse click" on selected software package from the Cloud market place. The main objective of the developed capability was the software tools conception with which users are able to design and install quickly their own highly reliable and highly available virtual IT-infrastructure for the organization of seismic (and in future other geophysical) data processing for either research or monitoring purposes. These tools provide access to any seismic station data available in open IP configuration from the different networks affiliated with different Institutions and Organizations. It allows also setting up your own network as you desire by selecting either regionally deployed stations or the worldwide global network based on stations selection form the global map. The processing software and products and research results could be easily monitored from everywhere using variety of user's devices form desk top computers to IT gadgets. Currents efforts of the development team are directed to achieve Scalability, Reliability and Sustainability (SRS) of proposed solutions allowing any user to run their applications with the confidence of no data loss and no failure of the monitoring or research software components. The system is suitable for quick rollout of NDC-in-Box software package developed for State Signatories and aimed for promotion of data processing collected by the IMS Network.
Design Curve Generation for 3D SiC Fiber Architecture
NASA Technical Reports Server (NTRS)
Lang, Jerry; Dicarlo, James A.
2014-01-01
The design tool provides design curves that allow a simple and quick way to examine multiple factors that can influence the processing and key properties of the preforms and their final SiC-reinforced ceramic composites without over obligating financial capital for the fabricating of materials. Tool predictions for process and fiber fraction properties have been validated for a HNS 3D preform.The virtualization aspect of the tool will be used to provide a quick generation of solid models with actual fiber paths for finite element evaluation to predict mechanical and thermal properties of proposed composites as well as mechanical displacement behavior due to creep and stress relaxation to study load sharing characteristic between constitutes for better performance.Tool predictions for the fiber controlled properties of the SiCSiC CMC fabricated from the HNS preforms will be valuated and up-graded from the measurements on these CMC
Implicit Self-Importance in an Interpersonal Pronoun Categorization Task
Fetterman, Adam K.; Robinson, Michael D.; Gilbertson, Elizabeth P.
2014-01-01
Object relations theories emphasize the manner in which the salience/importance of implicit representations of self and other guide interpersonal functioning. Two studies and a pilot test (total N = 304) sought to model such representations. In dyadic contexts, the self is a “you” and the other is a “me”, as verified in a pilot test. Study 1 then used a simple categorization task and found evidence for implicit self-importance: The pronoun “you” was categorized more quickly and accurately when presented in a larger font size, whereas the pronoun “me” was categorized more quickly and accurately when presented in a smaller font size. Study 2 showed that this pattern possesses value in understanding individual differences in interpersonal functioning. As predicted, arrogant people scored higher in implicit self-importance in the paradigm. Findings are discussed from the perspective of dyadic interpersonal dynamics. PMID:25419089
Caffrey, Emily A; Johansen, Mathew P; Higley, Kathryn A
2015-10-01
Radiological dosimetry for nonhuman biota typically relies on calculations that utilize the Monte Carlo simulations of simple, ellipsoidal geometries with internal radioactivity distributed homogeneously throughout. In this manner it is quick and easy to estimate whole-body dose rates to biota. Voxel models are detailed anatomical phantoms that were first used for calculating radiation dose to humans, which are now being extended to nonhuman biota dose calculations. However, if simple ellipsoidal models provide conservative dose-rate estimates, then the additional labor involved in creating voxel models may be unnecessary for most scenarios. Here we show that the ellipsoidal method provides conservative estimates of organ dose rates to small mammals. Organ dose rates were calculated for environmental source terms from Maralinga, the Nevada Test Site, Hanford and Fukushima using both the ellipsoidal and voxel techniques, and in all cases the ellipsoidal method yielded more conservative dose rates by factors of 1.2-1.4 for photons and 5.3 for beta particles. Dose rates for alpha-emitting radionuclides are identical for each method as full energy absorption in source tissue is assumed. The voxel procedure includes contributions to dose from organ-to-organ irradiation (shown here to comprise 2-50% of total dose from photons and 0-93% of total dose from beta particles) that is not specifically quantified in the ellipsoidal approach. Overall, the voxel models provide robust dosimetry for the nonhuman mammals considered in this study, and though the level of detail is likely extraneous to demonstrating regulatory compliance today, voxel models may nevertheless be advantageous in resolving ongoing questions regarding the effects of ionizing radiation on wildlife.
Buzid, Alyah; Muimhneacháin, Eoin Ó; Reen, F Jerry; Hayes, Phyllis E; Pardo, Leticia M; Shang, Fengjun; O'Gara, Fergal; Sperry, Jonathan; Luong, John H T; Glennon, Jeremy D; McGlacken, Gerard P
2016-09-01
Pseudomonas aeruginosa is a Gram-negative opportunistic pathogen, capable of surviving in a broad range of natural environments and quickly acquiring resistance. It is associated with hospital-acquired infections, particularly in patients with compromised immunity, and is the primary cause of morbidity and mortality in cystic fibrosis (CF) patients. P. aeruginosa is also of nosocomial importance on dairy farms and veterinary hospitals, where it is a key morbidity factor in bovine mastitis. P. aeruginosa uses a cell-cell communication system consisting of signalling molecules to coordinate bacterial secondary metabolites, biofilm formation, and virulence. Simple and sensitive methods for the detection of biomolecules as indicators of P. aeruginosa infection would be of great clinical importance. Here, we report the synthesis of the P. aeruginosa natural product, barakacin, which was recently isolated from the bovine ruminal strain ZIO. A simple and sensitive electrochemical method was used for barakacin detection using a boron-doped diamond (BDD) and glassy carbon (GC) electrodes, based on cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The influence of electrolyte pH on the peak potential and peak currents was also investigated. At pH 2.0, the peak current was linearly dependent on barakacin concentration (in the range used, 1-10 μM), with correlation coefficients greater than 0.98 on both electrodes. The detection limit (S/N = 3) on the BDD electrode was 100-fold lower than that obtained on the GC electrode. The optimized method using the BDD electrode was extended to bovine (cow feces) and human (sputum of a CF patient) samples. Spiked barakacin was easily detected in these matrices at a limit of 0.5 and 0.05 μM, respectively. Graphical abstract Electrochemical detection of barakacin.
Shinchi, Hiroyuki; Yuki, Nobuhiro; Ishida, Hideharu; Hirata, Koichi; Wakao, Masahiro; Suda, Yasuo
2015-01-01
Sugar chain binding antibodies have gained substantial attention as biomarkers due to their crucial roles in various disorders. In this study, we developed simple and quick detection method of anti-sugar chain antibodies in sera using our previously developed sugar chain-immobilized fluorescent nanoparticles (SFNPs) for the point-of-care diagnostics. Sugar chain structure on SFNPs was modified with the sugar moieties of the GM1 ganglioside via our original linker molecule to detect anti-GM1 antibodies. The structures and densities of the sugar moieties immobilized on the nanoparticles were evaluated in detail using lectins and sera containing anti-GM1 antibodies from patients with Guillain-Barré syndrome, a neurological disorder, as an example of disease involving anti-sugar chain antibodies. When optimized SFNPs were added to sera from patients with Guillain-Barré syndrome, fluorescent aggregates were able to visually detect under UV light in three hours. The sensitivity of the detection method was equivalent to that of the current ELISA method used for the diagnosis of Guillain-Barré syndrome. These results suggest that our method using SFNPs is suitable for the point-of-care diagnostics of diseases involving anti-sugar chain antibodies.
Size analysis of nanoparticles extracted from W/O emulsions.
Nagelreiter, C; Kotisch, H; Heuser, T; Valenta, C
2015-07-05
Nanosized particles are frequently used in many different applications, especially TiO2 nanoparticles as physical filters in sunscreens to protect the skin from UV radiation. However, concerns have arisen about possible health issues caused by nanoparticles and therefore, the assessment of the occurrence of nanoparticles is important in pharmaceutical and cosmetic formulations. In a previous work of our group, a method was presented to extract nanoparticles from O/W emulsions. But to respond to the needs of dry and sensitive skin, sunscreens of the water-in-oil emulsion type are available. In these, assessment of present nanoparticles is also an important issue, so the present study offers a method for extracting nanoparticles from W/O emulsions. Both methods emanate from the same starting point, which minimizes both effort and cost before the beginning of the assessment. By addition of NaOH pellets and centrifugation, particles were extracted from W/O emulsions and measured for their size and surface area by laser diffraction. With the simple equation Q=A/S a distinction between nanoparticles and microparticles was achieved in W/O emulsions, even in commercially available samples. The present method is quick and easy to implement, which makes it cost-effective. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Li, Q.; Wang, Y. L.; Li, H. C.; Zhang, M.; Li, C. Z.; Chen, X.
2017-12-01
Rainfall threshold plays an important role in flash flood warning. A simple and easy method, using Rational Equation to calculate rainfall threshold, was proposed in this study. The critical rainfall equation was deduced from the Rational Equation. On the basis of the Manning equation and the results of Chinese Flash Flood Survey and Evaluation (CFFSE) Project, the critical flow was obtained, and the net rainfall was calculated. Three aspects of the rainfall losses, i.e. depression storage, vegetation interception, and soil infiltration were considered. The critical rainfall was the sum of the net rainfall and the rainfall losses. Rainfall threshold was estimated after considering the watershed soil moisture using the critical rainfall. In order to demonstrate this method, Zuojiao watershed in Yunnan Province was chosen as study area. The results showed the rainfall thresholds calculated by the Rational Equation method were approximated to the rainfall thresholds obtained from CFFSE, and were in accordance with the observed rainfall during flash flood events. Thus the calculated results are reasonable and the method is effective. This study provided a quick and convenient way to calculated rainfall threshold of flash flood warning for the grass root staffs and offered technical support for estimating rainfall threshold.
Yoo, Do Hyeon; Shin, Wook-Geun; Lee, Jaekook; Yeom, Yeon Soo; Kim, Chan Hyeong; Chang, Byung-Uck; Min, Chul Hee
2017-11-01
After the Fukushima accident in Japan, the Korean Government implemented the "Act on Protective Action Guidelines Against Radiation in the Natural Environment" to regulate unnecessary radiation exposure to the public. However, despite the law which came into effect in July 2012, an appropriate method to evaluate the equivalent and effective doses from naturally occurring radioactive material (NORM) in consumer products is not available. The aim of the present study is to develop and validate an effective dose coefficient database enabling the simple and correct evaluation of the effective dose due to the usage of NORM-added consumer products. To construct the database, we used a skin source method with a computational human phantom and Monte Carlo (MC) simulation. For the validation, the effective dose was compared between the database using interpolation method and the original MC method. Our result showed a similar equivalent dose across the 26 organs and a corresponding average dose between the database and the MC calculations of < 5% difference. The differences in the effective doses were even less, and the result generally show that equivalent and effective doses can be quickly calculated with the database with sufficient accuracy. Copyright © 2017 Elsevier Ltd. All rights reserved.
Chen, Mei; Collins, Erin M; Tao, Lin; Lu, Chensheng
2013-11-01
The neonicotinoids have recently been identified as a potential contributing factor to the sudden decline in adult honeybee population, commonly known as colony collapse disorder (CCD). To protect the health of honeybees and other pollinators, a new, simple, and sensitive liquid chromatography-electrospray ionization mass spectrometry method was developed and validated for simultaneous determination of eight neonicotinoids, including acetamiprid, clothianidin, dinotefuran, flonicamid, imidacloprid, nitenpyram, thiacloprid, and thiamethoxam, in pollen and high-fructose corn syrup (HFCS). In this method, eight neonicotinoids, along with their isotope-labeled internal standards, were extracted from 2 g of pollen or 5 g of HFCS using an optimized quick, easy, cheap, effective, rugged, and safe extraction procedure. The method limits of detection in pollen and HFCS matrices were 0.03 ng/g for acetamiprid, clothianidin, dinotefuran, imidacloprid, thiacloprid, and thiamethoxam and ranged between 0.03 and 0.1 ng/g for nitenpyram and flonicamid. The precision and accuracy were well within the acceptable 20% range. Selectivity, linearity, lower limit of quantitation, matrix effect, recovery, and stability in autosampler were also evaluated during validation. This validated method has been used successfully in analyzing a set of pollen and HFCS samples collected for evaluating potential honeybee exposure to neonicotinoids.
Chemical test for mammalian feces in grain products: collaborative study.
Gerber, H R
1989-01-01
A collaborative study was conducted to validate the use of the AOAC alkaline phosphatase method for mammalian feces in corn meal, 44.B01-44.B06, for 7 additional products: brown rice cream, oat bran, grits, semolina, pasta flour, farina, and barley plus (a mixture of barley, oat bran, and brown rice). The proposed method determines the presence of alkaline phosphatase, an enzyme contained in mammalian feces, by using phenolphthalein diphosphate as the enzyme substrate in a test agar medium. Fecal matter is separated from the grain products by specific gravity differences in 1% test agar. As the product is distributed on liquid test agar, fecal fragments float while the grain products sink. The alkaline phosphatase cleaves phosphate radicals from phenolphthalein diphosphate, generating free phenolphthalein, which produces a pink to red-purple color around the fecal particles in the previously colorless medium. Collaborators' recovery averages ranged from 21.7 particles (72.3%) for oat bran to 25.3 particles (84.3%) for semolina at the 30 particle spike level. Overall average background was 0.4 positive reactions per food type. The collaborators reported that the method was quick, simple, and easy to use. The method has been approved interim official first action for all 7 grain products.
Rapid Quantitative Detection of Lactobacillus sakei in Meat and Fermented Sausages by Real-Time PCR
Martín, Belén; Jofré, Anna; Garriga, Margarita; Pla, Maria; Aymerich, Teresa
2006-01-01
A quick and simple method for quantitative detection of Lactobacillus sakei in fermented sausages was successfully developed. It is based on Chelex-100-based DNA purification and real-time PCR enumeration using a TaqMan fluorescence probe. Primers and probes were designed in the L. sakei 16S-23S rRNA intergenic transcribed spacer region, and the assay was evaluated using L. sakei genomic DNA and an artificially inoculated sausage model. The detection limit of this technique was approximately 3 cells per reaction mixture using both purified DNA and the inoculated sausage model. The quantification limit was established at 30 cells per reaction mixture in both models. The assay was then applied to enumerate L. sakei in real samples, and the results were compared to the MRS agar count method followed by confirmation of the percentage of L. sakei colonies. The results obtained by real-time PCR were not statistically significantly different than those obtained by plate count on MRS agar (P > 0.05), showing a satisfactory agreement between both methods. Therefore, the real-time PCR assay developed can be considered a promising rapid alternative method for the quantification of L. sakei and evaluation of the implantation of starter strains of L. sakei in fermented sausages. PMID:16957227
Rapid quantitative detection of Lactobacillus sakei in meat and fermented sausages by real-time PCR.
Martín, Belén; Jofré, Anna; Garriga, Margarita; Pla, Maria; Aymerich, Teresa
2006-09-01
A quick and simple method for quantitative detection of Lactobacillus sakei in fermented sausages was successfully developed. It is based on Chelex-100-based DNA purification and real-time PCR enumeration using a TaqMan fluorescence probe. Primers and probes were designed in the L. sakei 16S-23S rRNA intergenic transcribed spacer region, and the assay was evaluated using L. sakei genomic DNA and an artificially inoculated sausage model. The detection limit of this technique was approximately 3 cells per reaction mixture using both purified DNA and the inoculated sausage model. The quantification limit was established at 30 cells per reaction mixture in both models. The assay was then applied to enumerate L. sakei in real samples, and the results were compared to the MRS agar count method followed by confirmation of the percentage of L. sakei colonies. The results obtained by real-time PCR were not statistically significantly different than those obtained by plate count on MRS agar (P > 0.05), showing a satisfactory agreement between both methods. Therefore, the real-time PCR assay developed can be considered a promising rapid alternative method for the quantification of L. sakei and evaluation of the implantation of starter strains of L. sakei in fermented sausages.
Rapid detection of potyviruses from crude plant extracts.
Silva, Gonçalo; Oyekanmi, Joshua; Nkere, Chukwuemeka K; Bömer, Moritz; Kumar, P Lava; Seal, Susan E
2018-04-01
Potyviruses (genus Potyvirus; family Potyviridae) are widely distributed and represent one of the most economically important genera of plant viruses. Therefore, their accurate detection is a key factor in developing efficient control strategies. However, this can sometimes be problematic particularly in plant species containing high amounts of polysaccharides and polyphenols such as yam (Dioscorea spp.). Here, we report the development of a reliable, rapid and cost-effective detection method for the two most important potyviruses infecting yam based on reverse transcription-recombinase polymerase amplification (RT-RPA). The developed method, named 'Direct RT-RPA', detects each target virus directly from plant leaf extracts prepared with a simple and inexpensive extraction method avoiding laborious extraction of high-quality RNA. Direct RT-RPA enables the detection of virus-positive samples in under 30 min at a single low operation temperature (37 °C) without the need for any expensive instrumentation. The Direct RT-RPA tests constitute robust, accurate, sensitive and quick methods for detection of potyviruses from recalcitrant plant species. The minimal sample preparation requirements and the possibility of storing RPA reagents without cold chain storage, allow Direct RT-RPA to be adopted in minimally equipped laboratories and with potential use in plant clinic laboratories and seed certification facilities worldwide. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.
[Oxygen plasma-vulcanized deformable polydimethylsiloxane sheet culture substrates].
Zhang, Yiyi; Tao, Zulai
2003-06-01
A method of preparing deformable polydimethylsiloxane sheet culture substrates by oxygen plasma vulcanization was developed. As compared with the traditional heating vulcanization method, the substrates prepared in this way have hydrophilic surfaces, the adhesion and spreading of cells both occur quickly, and the wrinkling deformation of substrates develops quickly, too. In addition, the changes of wrinkles during treatment of cytochalasin D were observed, and the result shows that this technique has high temporal resolution.
A Quick and Easy Simplification of Benzocaine's NMR Spectrum
NASA Astrophysics Data System (ADS)
Carpenter, Suzanne R.; Wallace, Richard H.
2006-04-01
The preparation of benzocaine is a common experiment used in sophomore-level organic chemistry. Its straightforward procedure and predictable good yields make it ideal for the beginning organic student. Analysis of the product via NMR spectroscopy, however, can be confusing to the novice interpreter. An inexpensive, quick, and effective method for simplifying the NMR spectrum is reported. The method results in a spectrum that is cleanly integrated and more easily interpreted.
Ribbons of semithin sections: an advanced method with a new type of diamond knife.
Blumer, Michael J F; Gahleitner, P; Narzt, T; Handl, C; Ruthensteiner, B
2002-10-15
Complete series of semithin sections are imperative for 3-D reconstruction, but with traditional microtomy techniques it is difficult and time-consuming to trace stained and labeled structures. In the present study we introduce a method for making and collecting ribbons of semithin sections with a new, commercial available diamond knife (histo-jumbo-diamond knife, Diatome AG, Biel, Switzerland). The special feature of the diamond knife is the large water bath (boat) into which a glass slide can be dipped. The method has distinct advantages and the handling is simple. The resin block is trimmed into a truncated pyramid. Contact glue is applied to the leading face of the pyramid, which makes sections stick together to form a ribbon. Following sectioning, the ribbons are mounted onto glass slides and aligned in parallel. Stretching out and drying the ribbons on a hot plate is the final step of the method. Major advantages of this method are the perfect alignment of sections with identical orientation of structures, the completeness of series, and the significant saving of time. This facilitates tracing of stained and labeled structures, yielding quick 3-D reconstruction. Semithin sections can be cut from 0.5 to 2 micro m and several ribbons can be mounted side by side onto the slide. Two examples are presented to illustrate the advantages of the method.
Han, Guomin; Wang, Hua; Webb, Michael R; Waterhouse, Andrew L
2015-03-01
Carbonyl compounds are produced during fermentation and chemical oxidation during wine making and aging, and they are important to wine flavor and color stability. Since wine also contains these compounds as α-hydroxysulfonates as a result of their reaction with sulfur dioxide, an alkaline pre-treatment requiring oxygen exclusion has been used to release these bound carbonyls for analysis. By modifying the method to hydrolyze the hydroxysulfonates with heating and acid in the presence of 2,4-dinitrophenylhydrazine (DNPH), the carbonyl compounds are simultaneously and quickly released and derivatized, resulting in a simpler and more rapid method. In addition, the method avoids air exclusion complications during hydrolysis by the addition of sulfur dioxide. The method was optimized for temperature, reaction time, and the concentrations of DNPH, sulfur dioxide and acid. The hydrazones were shown to be stable for 10 h, adequate time for chromatographic analysis by HPLC-DAD/MS. This method is demonstrated for 2-ketoglutaric acid, pyruvic acid, acetoin and acetaldehyde, wine carbonyls of very different reactivities, and it offers good specificity, high recovery and low limits of detection. This new rapid, simple method is demonstrated for the measurement of carbonyl compounds in a range of wines of different ages and grape varieties. Copyright © 2014 Elsevier B.V. All rights reserved.
Quick Phases of Infantile Nystagmus Show the Saccadic Inhibition Effect
Harrison, James J.; Sumner, Petroc; Dunn, Matt J.; Erichsen, Jonathan T.; Freeman, Tom C. A.
2015-01-01
Purpose. Infantile nystagmus (IN) is a pathological, involuntary oscillation of the eyes consisting of slow, drifting eye movements interspersed with rapid reorienting quick phases. The extent to which quick phases of IN are programmed similarly to saccadic eye movements remains unknown. We investigated whether IN quick phases exhibit ‘saccadic inhibition,' a phenomenon typically related to normal targeting saccades, in which the initiation of the eye movement is systematically delayed by task-irrelevant visual distractors. Methods. We recorded eye position from 10 observers with early-onset idiopathic nystagmus while task-irrelevant distractor stimuli were flashed along the top and bottom of a large screen at ±10° eccentricity. The latency distributions of quick phases were measured with respect to these distractor flashes. Two additional participants, one with possible albinism and one with fusion maldevelopment nystagmus syndrome, were also tested. Results. All observers showed that a distractor flash delayed the execution of quick phases that would otherwise have occurred approximately 100 ms later, exactly as in the standard saccadic inhibition effect. The delay did not appear to differ between the two main nystagmus types under investigation (idiopathic IN with unidirectional and bidirectional jerk). Conclusions. The presence of the saccadic inhibition effect in IN quick phases is consistent with the idea that quick phases and saccades share a common programming pathway. This could allow quick phases to take on flexible, goal-directed behavior, at odds with the view that IN quick phases are stereotyped, involuntary eye movements. PMID:25670485
QuickCash: Secure Transfer Payment Systems
Alhothaily, Abdulrahman; Alrawais, Arwa; Song, Tianyi; Lin, Bin; Cheng, Xiuzhen
2017-01-01
Payment systems play a significant role in our daily lives. They are an important driver of economic activities and a vital part of the banking infrastructure of any country. Several current payment systems focus on security and reliability but pay less attention to users’ needs and behaviors. For example, people may share their bankcards with friends or relatives to withdraw money for various reasons. This behavior can lead to a variety of privacy and security issues since the cardholder has to share a bankcard and other sensitive information such as a personal identification number (PIN). In addition, it is commonplace that cardholders may lose their cards, and may not be able to access their accounts due to various reasons. Furthermore, transferring money to an individual who has lost their bankcard and identification information is not a straightforward task. A user-friendly person-to-person payment system is urgently needed to perform secure and reliable transactions that benefit from current technological advancements. In this paper, we propose two secure fund transfer methods termed QuickCash Online and QuickCash Offline to transfer money from peer to peer using the existing banking infrastructure. Our methods provide a convenient way to transfer money quickly, and they do not require using bank cards or any identification card. Unlike other person-to-person payment systems, the proposed methods do not require the receiving entity to have a bank account, or to perform any registration procedure. We implement our QuickCash payment systems and analyze their security strengths and properties. PMID:28608846
QuickCash: Secure Transfer Payment Systems.
Alhothaily, Abdulrahman; Alrawais, Arwa; Song, Tianyi; Lin, Bin; Cheng, Xiuzhen
2017-06-13
Payment systems play a significant role in our daily lives. They are an important driver of economic activities and a vital part of the banking infrastructure of any country. Several current payment systems focus on security and reliability but pay less attention to users' needs and behaviors. For example, people may share their bankcards with friends or relatives to withdraw money for various reasons. This behavior can lead to a variety of privacy and security issues since the cardholder has to share a bankcard and other sensitive information such as a personal identification number (PIN). In addition, it is commonplace that cardholders may lose their cards, and may not be able to access their accounts due to various reasons. Furthermore, transferring money to an individual who has lost their bankcard and identification information is not a straightforward task. A user-friendly person-to-person payment system is urgently needed to perform secure and reliable transactions that benefit from current technological advancements. In this paper, we propose two secure fund transfer methods termed QuickCash Online and QuickCash Offline to transfer money from peer to peer using the existing banking infrastructure. Our methods provide a convenient way to transfer money quickly, and they do not require using bank cards or any identification card. Unlike other person-to-person payment systems, the proposed methods do not require the receiving entity to have a bank account, or to perform any registration procedure. We implement our QuickCash payment systems and analyze their security strengths and properties.
A new field method to characterise the runoff generation potential of burned hillslopes
NASA Astrophysics Data System (ADS)
Sheridan, Gary; Lane, Patrick; Langhans, Christoph
2016-04-01
The prediction of post fire runoff generation is critical for the estimation of post fire erosion processes and rates. Typical field measures for determining infiltration model parameters include ring infiltrometers, tension infiltrometers, rainfall simulators and natural runoff plots. However predicting the runoff generating potential of post-fire hillslopes is difficult due to the high spatial variability of soil properties relative to the size of the measurement method, the poorly understood relationship between water repellence and runoff generation, known scaling issues with all the above hydraulic measurements, and logistical limitations for measurements in remote environments. In this study we tested a new field method for characterizing surface runoff generation potential that overcomes these limitations and is quick, simple and cheap to apply in the field. The new field method involves the manual application of a 40mm depth of Brilliant Blue FCF food dye along a 10cm wide and 5m long transect along the contour under slightly-ponded conditions. After 24 hours the transect is excavated to a depth of 10cm and the percentage dyed area within the soil profile recorded manually. The dyed area is an index of infiltration potential of the soil during intense rainfall events, and captures both spatial variability and water repellence effects. The dye measurements were made adjacent to long term instrumented post fire rainfall-runoff plots on 7 contrasting soil types over a 6 month period, and the results show surprisingly strong correlations (r2 = 0.9) between the runoff-ratio from the plots and the dyed area. The results are used to develop an initial conceptual model that links the dye index with an infiltration model and parameters suited to burnt hillslopes. The capacity of this method to provide a simple, and reliable indicator of post fire runoff potential from different fire severities, soil types and treatments is explored in this presentation.
Instant freezing of impacting wax drops
NASA Astrophysics Data System (ADS)
Ponomarenko, Alexandre; Virot, Emmanuel; Rubinstein, Shmuel
2015-11-01
We present the impact of hot liquid drops of wax on surfaces whose temperature is below the solidifying temperature of the drops. During the fall the drops remain mostly liquid, but upon impact, their temperature quickly decreases resulting in the solidification of the drop. Depending on the impact energy, drops size and the temperature difference between the drop and the surface this results in plethora of solid shapes: simple lenses, triangular drops, spherical caps and popped popcorn shapes.
Video instrumentation for radionuclide angiocardiography.
NASA Technical Reports Server (NTRS)
Kriss, J. P.
1973-01-01
Two types of videoscintiscopes for performing radioisotopic angiocardiography with a scintillation camera are described, and use of these instruments in performing clinical studies is illustrated. Radionuclide angiocardiography is a simple, quick and accurate procedure recommended as a screening test for patients with a variety of congenital and acquired cardiovascular lesions. When performed in conjunction with coronary arterial catheterization, dynamic radionuclide angiography may provide useful information about regional myocardial perfusion. Quantitative capabilities greatly enhance the potential of this diagnostic tool.
Testing and numerical modeling of hypervelocity impact damaged Space Station multilayer insulation
NASA Technical Reports Server (NTRS)
Rule, William K.
1992-01-01
Results are presented of experiments measuring the degradation of the insulating capabilities of the multilayer insulation (MLI) of the Space Station Freedom, when subjected to hypervelocity impact damage. A simple numerical model was developed for use in an engineering design environment for quick assessment of thermal effect of the impact. The model was validated using results from thermal vacuum tests on MLI with simulated damage. The numerical model results agreed with experimental data.
Rubino, C; Marongiu, F; Manzo, M J; Tedde, G; Madonia, M; Campus, G V; Farace, F
2014-06-01
We have devised a low cost system to quickly infiltrate tumescent solution: we call it the "Tedde's system". This low-cost system offers an improvement in quality and quantity of the infiltration because all the procedure depends on the operators, reducing also the time of the infiltration and consequently of the whole surgical procedure. Moreover, this system can be applied to other surgical procedure that requires large infiltration volumes.
Symmetries and "simple" solutions of the classical n-body problem
NASA Astrophysics Data System (ADS)
Chenciner, Alain
2006-03-01
The Lagrangian of the classical n-body problem has well known symmetries: isometries of the ambient Euclidean space (translations, rotations, reflexions) and changes of scale coming from the homogeneity of the potential. To these symmetries are associated "simple" solutions of the problem, the so-called homographic motions, which play a basic role in the global understanding of the dynamics. The classical subproblems (planar, isosceles) are also consequences of the existence of symmetries: invariance under reflexion through a plane in the first case, invariance under exchange of two equal masses in the second. In these two cases, the symmetry acts at the level of the "shape space" (the oriented one in the first case) whose existence is the main difference between the 2-body problem and the (n ≥ 3)-body problem. These symmetries of the Lagrangian imply symmetries of the action functional, which is defined on the space of regular enough loops of a given period in the configuration space of the problem. Minimization of the action under well-chosen symmetry constraints leads to remarkable solutions of the n-body problem which may also be called simple and could play after the homographic ones the role of organizing centers in the global dynamics. In [13] and [16], I have given a survey of the new classes of solutions which had been obtained in this way, mainly choreographies of n equal masses in a plane or in space and generalized Hip-Hops of at least 4 arbitrary masses in space. I give here an updated overview of the results and a quick glance at the methods of proofs.
ERIC Educational Resources Information Center
Schreyer, Paul R.
2012-01-01
Given our aging and crowded schools, today's administrators have to focus their attention on modernizing facilities. The Job Order Contracting (JOC) procurement method allows school administrators to complete a large number of high quality maintenance projects quickly with a single, competitively bid contract. The JOC process fits schools' unique…
[Assessment of pragmatics from verbal spoken data].
Gallardo-Paúls, B
2009-02-27
Pragmatic assessment is usually complex, long and sophisticated, especially for professionals who lack specific linguistic education and interact with impaired speakers. To design a quick method of assessment that will provide a quick general evaluation of the pragmatic effectiveness of neurologically affected speakers. This first filter will allow us to decide whether a detailed analysis of the altered categories should follow. Our starting point was the PerLA (perception, language and aphasia) profile of pragmatic assessment designed for the comprehensive analysis of conversational data in clinical linguistics; this was then converted into a quick questionnaire. A quick protocol of pragmatic assessment is proposed and the results found in a group of children with attention deficit hyperactivity disorder are discussed.
NASA Astrophysics Data System (ADS)
Hronusov, V. V.
2006-12-01
We suggest a method of using external public servers for rearranging, restructuring and rapid sharing of environmental data for the purpose of quick presentations in numerous GE clients. The method allows to add new philosophy for the presentation (publication) of the data (mostly static) stored in the public domain (e.g., Blue Marble, Visible Earth, etc). - The new approach is generated by publishing freely accessible spreadsheets which contain enough information and links to the data. Due to the fact that most of the large depositories of the data on the environmental monitoring have rather simple net address system as well as simple hierarchy mostly based on the date and type of the data, it is possible to develop the http-based link to the file which contains the data. Publication of new data on the server is recorded by a simple entering a new address into a cell in the spreadsheet. At the moment we use the EditGrid (www.editgrid.com) system as a spreadsheet platform. The generation of kml-codes is achieved on the basis of XML data and XSLT procedures. Since the EditGride environment supports "fetch" and similar commands, it is possible to create"smart-adaptive" KML generation on the fly based on the data streams from RSS and XML sources. The previous GIS-based methods could combine hi-definition data combined from various sources, but large- scale comparisons of dynamic processes have been usually out of reach of the technology. The suggested method allows unlimited number of GE clients to view, review and compare dynamic and static process of previously un-combinable sources, and on unprecedent scales. The ease of automated or computer-assisted georeferencing has already led to translation about 3000 raster public domain imagery, point and linear data sources into GE-language. In addition the suggested method allows a user to create rapid animations to demonstrate dynamic processes; roducts of high demand in education, meteorology, volcanology and potentially in a number of industries. In general it is possible to state that the new approach, which we have tested on numerous projects, saves times and energy in creating huge amounts of georeferenced data of various kinds, and thus provided an excellent tools for education and science.
NASA Astrophysics Data System (ADS)
Sakaguchi, Toshimasa; Fujigaki, Motoharu; Murata, Yorinobu
2015-03-01
Accurate and wide-range shape measurement method is required in industrial field. The same technique is possible to be used for a shape measurement of a human body for the garment industry. Compact 3D shape measurement equipment is also required for embedding in the inspection system. A shape measurement by a phase shifting method can measure the shape with high spatial resolution because the coordinates can be obtained pixel by pixel. A key-device to develop compact equipment is a grating projector. Authors developed a linear LED projector and proposed a light source stepping method (LSSM) using the linear LED projector. The shape measurement euipment can be produced with low-cost and compact without any phase-shifting mechanical systems by using this method. Also it enables us to measure 3D shape in very short time by switching the light sources quickly. A phase unwrapping method is necessary to widen the measurement range with constant accuracy for phase shifting method. A general phase unwrapping method with difference grating pitches is often used. It is one of a simple phase unwrapping method. It is, however, difficult to apply the conventional phase unwrapping algorithm to the LSSM. Authors, therefore, developed an expansion unwrapping algorithm for the LSSM. In this paper, an expansion algorithm of measurement range suited for 3D shape measurement using two pitches of projected grating with the LSSM was evaluated.
QuickStrike ASOC Battlefield Simulation: Preparing the War Fighter to Win
NASA Technical Reports Server (NTRS)
Jones, Richard L.
2010-01-01
The QuickStrike ASOC (Air Support Operations Center) Battlefield Simulation fills a crucial gap in USAF and United Kingdom Close Air Support (CAS) and airspace manager training. The system now provides six squadrons with the capability to conduct total-mission training events whenever the personnel and time are available. When the 111th ASOC returned from their first deployment to Afghanistan they realized the training available prior to deployment was inadequate. They sought an organic training capability focused on the ASOC mission that was low cost, simple to use, adaptable, and available now. Using a commercial off-the-shelf simulation, they developed a complete training system by adapting the simulation to their training needs. Through more than two years of spiral development, incorporating lessons learned, the system has matured, and can now realistically replicate the Tactical Operations Center (TOC) in Kabul, Afghanistan, the TOC supporting the mission in Iraq, or can expand to support a major conflict scenario. The training system provides a collaborative workspace for the training audience and exercise control group via integrated software and workstations that can easily adapt to new mission reqUirements and TOC configurations. The system continues to mature. Based on inputs from the war fighter, new capabilities have been incorporated to add realism and simplify the scenario development process. The QuickStrike simulation can now import TBMCS Air Tasking Order air mission data and can provide air and ground tracks to a common operating picture; presented through either C2PC or JADOCS. This oranic capability to practice team processes and tasks and to conduct mission rehearsals proved its value in the 111 h ASOS's next deployment. The ease of scenario development and the simple to learn and intuitive gamelike interface enables the squadrons to develop and share scenarios incorporating lessons learned from every deployment. These war fighters have now filled the training gap and have the capability they need to train to win.